Science.gov

Sample records for acetate chromatographic separation

  1. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  2. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  3. Selective liquid chromatographic separation of yttrium from heavier rare earth elements using acetic acid as a novel eluent.

    PubMed

    Kifle, Dejene; Wibetoe, Grethe

    2013-09-13

    One of the major difficulties in the rare earth elements separation is purification of yttrium from heavy rare earth elements. Thus, an HPLC method using acetic acid as novel eluent was explored for selective separation of yttrium form the heavy rare earth elements. When acetic acid is used as a mobile phase yttrium eluted with the lighter lanthanides. This is contrary to its relative position amongst heavier lanthanides when eluents commonly used for separation of rare earth elements were employed. The shift in elution position of yttrium with acetic acid as eluent may reflect a relatively lower stability constant of the yttrium-AcOH complex (in the same order as for the lighter lanthanides) compared to the corresponding AcOH complexes with heavy lanthanides, enabling selective separation of yttrium from the latter. The method was successfully used for selective separation of yttrium in mixed rare earth sample containing about 80% of yttrium and about 20% of heavy rare earth oxides. Thus, the use of AcOH as eluent is an effective approach for separating and determining the trace amounts of heavy rare earth elements in large amounts of yttrium matrix. Separation was performed on C18 column by running appropriate elution programs. The effluent from the column was monitored with diode array detector at absorbance wavelength of 658nm after post column derivatization with Arsenazo III.

  4. Chromatographic Separation of Glucose and Fructose

    NASA Astrophysics Data System (ADS)

    Kuptsevich, Yu E.; Larionov, Oleg G.; Stal'naya, I. D.; Nakhapetyan, L. A.; Pronin, A. Ya

    1987-03-01

    The structures, mutarotation, and the physicochemical properties of glucose and fructose as well as methods for their separation are examined. Their chromatographic separation on cation exchangers in the calcium-form is discussed in detail. A theory of the formation of complexes of carbohydrates with metal cations is described and the mechanism of the separation of glucose and fructose on cation exchangers in the calcium-form is discussed in detail. Factors influencing the chromatographic separation of glucose and fructose on sulphonic acid cation-exchange resins are also considered. The bibliography includes 138 references.

  5. Packed multi-channels for parallel chromatographic separations in microchips.

    PubMed

    Nagy, Andrea; Gaspar, Attila

    2013-08-23

    Here we report on a simple method to fabricate microfluidic chip incorporating multi-channel systems packed by conventional chromatographic particles without the use of frits. The retaining effectivities of different bottlenecks created in the channels were studied. For the parallel multi-channel chromatographic separations several channel patterns were designed. The obtained multipackings were applied for parallel separations of dyes. The implementation of several chromatographic separation units in microscopic size makes possible faster and high throughput separations.

  6. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    SciTech Connect

    Liu, Ying

    2004-01-01

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  7. Chromatographic Separation of Vitamin E Enantiomers.

    PubMed

    Fu, Ju-Yen; Htar, Thet-Thet; De Silva, Leanne; Tan, Doryn Meam-Yee; Chuah, Lay-Hong

    2017-02-04

    Vitamin E is recognized as an essential vitamin since its discovery in 1922. Most vegetable oils contain a mixture of tocopherols and tocotrienols in the vitamin E composition. Structurally, tocopherols and tocotrienols share a similar chromanol ring and a side chain at the C-2 position. Owing to the three chiral centers in tocopherols, they can appear as eight different stereoisomers. Plant sources of tocopherol are naturally occurring in the form of RRR while synthetic tocopherols are usually in the form of all-racemic mixture. Similarly, with only one chiral center, natural tocotrienols occur as the R-isoform. In this review, we aim to discuss a few chromatographic methods that had been used to separate the stereoisomers of tocopherols and tocotrienols. These methods include high performance liquid chromatography, gas chromatography and combination of both. The review will focus on method development including selection of chiral columns, detection method and choice of elution solvent in the context of separation efficiency, resolution and chiral purity. The applications for separation of enantiomers in vitamin E will also be discussed especially in terms of the distinctive biological potency among the stereoisoforms.

  8. Numerical Simulation of an Optical Chromatographic Separator

    DTIC Science & Technology

    2009-02-02

    its close relative, Bacillus thuringiensis ," Anal. Chem. 78, 3221-3225 (2006). 10. S. J. Hart, A. Terray, K. L. Kuhn, J. Arnold, and T. A. Leski...Terray, T. A. Leski, J. Arnold, and R. Stroud, "Discovery of a significant optical chromatographic difference between spores of Bacillus anthracis and

  9. Gas chromatographic separation of hydrogen isotopes using metal hydrides

    SciTech Connect

    Aldridge, F.T.

    1984-05-09

    A study was made of the properties of metal hydrides which may be suitable for use in chromatographic separation of hydrogen isotopes. Sixty-five alloys were measured, with the best having a hydrogen-deuterium separation factor of 1.35 at 60/sup 0/C. Chromatographic columns using these alloys produced deuterium enrichments of up to 3.6 in a single pass, using natural abundance hydrogen as starting material. 25 references, 16 figures, 4 tables.

  10. Fast gas chromatographic separation of biodiesel.

    SciTech Connect

    Pauls, R. E.

    2011-05-01

    A high-speed gas chromatographic method has been developed to determine the FAME distribution of B100 biodiesel. The capillary column used in this work has dimensions of 20 m x 0.100 mm and is coated with a polyethylene glycol film. Analysis times are typically on the order of 4-5 min depending upon the composition of the B100. The application of this method to a variety of vegetable and animal derived B100 is demonstrated. Quantitative results obtained with this method were in close agreement with those obtained by a more conventional approach on a 100 m column. The method, coupled with solid-phase extraction, was also found suitable to determine the B100 content of biodiesel-diesel blends.

  11. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    USGS Publications Warehouse

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  12. High-performance liquid chromatographic separation of subcomponents of antimycin A.

    PubMed

    Abidi, S L

    1988-08-05

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, A1a, A1b, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins A1, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpreted based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  13. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    ERIC Educational Resources Information Center

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  14. Cation exchange chromatographic elution and separation of rubidium

    SciTech Connect

    Mehta, V.P.; Khopkar, S.M.

    1982-01-01

    The systematic cation exchange chromatographic separation of rubidium on Dowex 50W-X8 was carried out with mineral acids and their salts as eluants.A selectivity scale for various eluants in terms of the elution constant was devised. Rubidium was separated from a large number of elements in binary mixtures by the process of gradient or selective elutions or selective sorption. The noteworthy feature of the method is the sequential separation of rubidium from alkali as well as alkaline earth elements.

  15. Separating acetic acid from furol (furfural) by electrodialysis method

    SciTech Connect

    Guan, S.F.; Li, C.S. Ye, S.T.; Shen, S.Y.; Wang, Y.T.; Yu, S.H.

    1981-01-01

    Furfural production by hydrolysis of fibrous plant materials is accompanied by formation of acetic acid in amounts depending on the material used. The amount of acetic formed in the hydrolysis of the fruit shell of oil-tea camellia (Camellia oleosa) (an oilseed-bearing tree) is equal to the amount of furfural. The acetic acid can be separated from the furfural and concentrated to 10% by electrodialysis. A smaller amount of furfural is separated with acetic acid.

  16. Rotating annular chromatograph for continuous metal separations and recovery

    SciTech Connect

    Begovich, J.M.; Sisson, W.G.

    1981-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. By continuously introducing the feed material to be separated at a stationary point at the top of the bed and eluent everywhere else around the annulus, elution chromatography occurs. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence, the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effect of annulus width and diameter has recently been studied using the same device with a 50.8-mm-wide annulus and another 0.6-m-long chromatograph with an 89-mm diameter and annulus widths of 6.4, 12.7, and 22.2 mm. These columns have been constructed of Plexiglas and typically operate at a gauge pressure of 175 kPa. To further study the effect of size and pressure, a new 445-mm-diam by 1-m-long column with a 31.8-mm-wide annulus has been fabricated. Its metal construction allows preparative-scale operation with a wide variety of liquids at pressures to 1.3 MPa. Three metal recovery systems have been explored: (1) separation of iron and aluminum in ammonium sulfate-sulfuric acid solutions; (2) separation of hafnium from zirconium in sulfuric acid solutions; and (3) the separation of copper, nickel, and cobalt in ammonium carbonate solutions. This last system simulates the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. It has been studied, using similar conditions, on each of the chromatographs, and the results demonstrate the effect of column dimensions on the quality and quantity of the separation. 8 figures, 1 table.

  17. Can enantiomers be separated in achiral chromatographic systems?

    NASA Astrophysics Data System (ADS)

    Davankov, V. A.

    2016-10-01

    Consideration of chromatography of a nonracemic mixture on an achiral sorbent from a stereochemical point of view allows the claim that partial separation of the excess enantiomer zone from the racemate zone is possible only with analytes capable of self-associating under the conditions of the chromatographic column. It is from these positions that features of this process can be explained and conditions for its maximal proceeding formulated.

  18. Chromatographic separation of phenylpropanol enantiomers on a quinidine carbamate-type chiral stationary phase

    SciTech Connect

    Asnin, Leonid; Guiochon, Georges A

    2005-07-01

    The retention and the separation of the enantiomers of 1-phenylpropanol (1PP), 2-phenylpropanol (2PP), and 3-chloro-1-phenylpropanol (3CPP) on silica-bonded quinidine carbamate under normal phase HPLC conditions were investigated. A relatively high selectivity of the stationary phase for 3CPP and 1PP ({alpha} {approx} 1.07-1.09) was achieved with eluents containing ethyl acetate as the polar modifier. These mobile phases were examined in detail. Based on the set of chromatographic and thermodynamic data collected, conclusions regarding the mechanism of enantioselectivity and the structure of the selector chiral center are made.

  19. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chromatographic separation material for clinical... Laboratory Instruments § 862.2230 Chromatographic separation material for clinical use. (a) Identification. A chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents,...

  20. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chromatographic separation material for clinical... Laboratory Instruments § 862.2230 Chromatographic separation material for clinical use. (a) Identification. A chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents,...

  1. Multi-objective optimization of chromatographic rare earth element separation.

    PubMed

    Knutson, Hans-Kristian; Holmqvist, Anders; Nilsson, Bernt

    2015-10-16

    The importance of rare earth elements in modern technological industry grows, and as a result the interest for developing separation processes increases. This work is a part of developing chromatography as a rare earth element processing method. Process optimization is an important step in process development, and there are several competing objectives that need to be considered in a chromatographic separation process. Most studies are limited to evaluating the two competing objectives productivity and yield, and studies of scenarios with tri-objective optimizations are scarce. Tri-objective optimizations are much needed when evaluating the chromatographic separation of rare earth elements due to the importance of product pool concentration along with productivity and yield as process objectives. In this work, a multi-objective optimization strategy considering productivity, yield and pool concentration is proposed. This was carried out in the frame of a model based optimization study on a batch chromatography separation of the rare earth elements samarium, europium and gadolinium. The findings from the multi-objective optimization were used to provide with a general strategy for achieving desirable operation points, resulting in a productivity ranging between 0.61 and 0.75 kgEu/mcolumn(3), h(-1) and a pool concentration between 0.52 and 0.79 kgEu/m(3), while maintaining a purity above 99% and never falling below an 80% yield for the main target component europium.

  2. Optimization of the ion chromatographic quantification of airborne fluoride, acetate and formate in the Metropolitan Museum of Art, New York.

    PubMed

    Kontozova-Deutsch, Velichka; Deutsch, Felix; Bencs, László; Krata, Agnieszka; Van Grieken, René; De Wael, Karolien

    2011-10-30

    Ion chromatographic (IC) methods have been compared in order to achieve an optimal separation of fluoride, acetate and formate under various elution conditions on two formerly introduced analytical columns (i and ii) and a novel one (iii): (i) an IonPac AS14 (250 mm × 4 mm I.D.), (ii) Allsep A-2 (150 mm × 4.6mm I.D.), and (iii) an IC SI-50 4E (250 mm (length) × 4mm (internal diameter - I.D.)). The IC conditions for the separation of the anions concerned were optimized on the IC SI-50 4E column. A near baseline separation of these anions was attained on the IonPac AS14, whereas the peaks of fluoride and acetate could not be resolved on the Allsep A-2. A baseline separation for the three anions was achieved on the IC SI-50 4E column, when applying an eluent mixture of 3.2 mmol/L Na(2)CO(3) and 1.0 mmol/L NaHCO(3) with a flow rate of 1.0 mL/min. The highest precision of 1.7, 3.0 and 2.8% and the best limits of detection (LODs) of 0.014, 0.22 and 0.17 mg/L for fluoride, acetate and formate, respectively, were obtained with the IC SI-50 4E column. Hence, this column was applied for the determination of the acetic and formic acid contents of air samples taken by means of passive gaseous sampling at the Metropolitan Museum of Art in New York, USA. Atmospheric concentrations of acetic and formic acid up to 1050 and 450 μg/m(3), respectively, were found in non-aerated showcases of the museum. In galleries and outdoors, rather low levels of acetic and formic acid were detected with average concentrations of 50 and 10 μg/m(3), respectively. The LOD data of acetate and formate on the IC SI-50 4E column correspond to around 0.5 μg/m(3) for both acetic and formic acid in air samples.

  3. Capillary gas chromatographic analysis of alditol acetates of neutral and amino sugars in bacterial cell walls.

    PubMed

    Fox, A; Morgan, S L; Hudson, J R; Zhu, Z T; Lau, P Y

    1983-02-18

    Several improvements in the preparation of alditol acetates of neutral and amino sugars and in the preparation of glass capillary columns for their separation are described. Modifications in sample preparation permitted the simultaneous processing of multiple samples and eliminated extraneous background peaks. Efficient and inert columns were tailor-made for the separation of alditol acetates of neutral and amino sugars by leaching glass capillaries with aqueous hydrochloric acid and dynamically coating with SP-2330.

  4. Chromatographic separation of neodymium isotopes by using chemical exchange process.

    PubMed

    Ismail, I M; Ibrahim, M; Aly, H F; Nomura, M; Fujii, Y

    2011-05-20

    The neodymium isotope effects were investigated in Nd-malate ligand exchange system using the highly porous cation exchange resin SQS-6. The temperature of the chromatographic columns was kept constant at 50°C by temperature controlled water passed through the columns jackets. The separation coefficient of neodymium isotopes, ɛ's, was calculated from the isotopic ratios precisely measured by means of an ICP mass spectrometer equipped with nine collectors as ion detectors. The separation coefficient, ɛ×10(5), were calculated and found to be 1.4, 4.8, 5.4, 10.6, 16.8 and 20.2 for (143)Nd, (144)Nd, (145)Nd, (146)Nd, (148)Nd and (150)Nd, respectively.

  5. Mathematical model for multicomponent separations on the continuous annular chromatograph

    SciTech Connect

    Bratzler, R.L.; Begovich, J.M.

    1980-12-01

    A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally.

  6. Method for the chromatographic separation of cations from aqueous samples

    DOEpatents

    Horwitz, E.P.; Chiarizia, R.; Dietz, M.L.

    1997-07-29

    An extraction chromatographic material is described for extracting metal cations from a liquid stream. The extraction chromatographic material is prepared by adsorbing a diesterified methanediphosphonic acid on an inert particulate support. 7 figs.

  7. Separation studies of As(III), Sb(III) and Bi(III) by reversed-phase paper chromatographic technique

    SciTech Connect

    Raman, B.; Shinde, V.M.

    1987-07-01

    Reversed-phase paper chromatographic separations of As(III), Sb(III) and Bi(III) have been carried out on Whatman No 1 filter paper impregnated with triphenylphosphine oxide as stationary phase and using organic complexing agents such as sodium acetate, sodium succinate and sodium malonate solutions as active mobile phases. Results for the separation of binary and ternary mixtures are reported and the method has been successfully applied to the separation and detection of these elements present in real samples and at ppm level concentration.

  8. Chromatographic Studies of Protein-Based Chiral Separations.

    PubMed

    Bi, Cong; Zheng, Xiwei; Azaria, Shiden; Beeram, Sandya; Li, Zhao; Hage, David S

    2016-09-01

    The development of separation methods for the analysis and resolution of chiral drugs and solutes has been an area of ongoing interest in pharmaceutical research. The use of proteins as chiral binding agents in high-performance liquid chromatography (HPLC) has been an approach that has received particular attention in such work. This report provides an overview of proteins that have been used as binding agents to create chiral stationary phases (CSPs) and in the use of chromatographic methods to study these materials and protein-based chiral separations. The supports and methods that have been employed to prepare protein-based CSPs will also be discussed and compared. Specific types of CSPs that are considered include those that employ serum transport proteins (e.g., human serum albumin, bovine serum albumin, and alpha1-acid glycoprotein), enzymes (e.g., penicillin G acylase, cellobiohydrolases, and α-chymotrypsin) or other types of proteins (e.g., ovomucoid, antibodies, and avidin or streptavidin). The properties and applications for each type of protein and CSP will also be discussed in terms of their use in chromatography and chiral separations.

  9. Chromatographic Studies of Protein-Based Chiral Separations

    PubMed Central

    Bi, Cong; Zheng, Xiwei; Azaria, Shiden; Beeram, Sandya; Li, Zhao; Hage, David S.

    2016-01-01

    The development of separation methods for the analysis and resolution of chiral drugs and solutes has been an area of ongoing interest in pharmaceutical research. The use of proteins as chiral binding agents in high-performance liquid chromatography (HPLC) has been an approach that has received particular attention in such work. This report provides an overview of proteins that have been used as binding agents to create chiral stationary phases (CSPs) and in the use of chromatographic methods to study these materials and protein-based chiral separations. The supports and methods that have been employed to prepare protein-based CSPs will also be discussed and compared. Specific types of CSPs that are considered include those that employ serum transport proteins (e.g., human serum albumin, bovine serum albumin, and alpha1-acid glycoprotein), enzymes (e.g., penicillin G acylase, cellobiohydrolases, and α-chymotrypsin) or other types of proteins (e.g., ovomucoid, antibodies, and avidin or streptavidin). The properties and applications for each type of protein and CSP will also be discussed in terms of their use in chromatography and chiral separations. PMID:28344977

  10. Chromatographic Separations Using Solid-Phase Extraction Cartridges: Separation of Wine Phenolics

    NASA Astrophysics Data System (ADS)

    Brenneman, Charles A.; Ebeler, Susan E.

    1999-12-01

    We describe a simple laboratory experiment that demonstrates the principles of chromatographic separation using solid-phase extraction columns and red wine. By adjusting pH and mobile phase composition, the wine is separated into three fractions of differing polarity. The content of each fraction can be monitored by UV-vis spectroscopy. When the experiment is combined with experiments involving HPLC or GC separations, students gain a greater appreciation for and understanding of the highly automated instrumental systems currently available. In addition, they learn about the chemistry of polyphenolic compounds, which are present in many foods and beverages and which are receiving much attention for their potentially beneficial health effects.

  11. Improvement of the chromatographic separation of several 1,4-dihydropyridines calcium channel antagonist drugs by experimental design.

    PubMed

    Baranda, Ana B; Etxebarria, Nestor; Jiménez, Rosa M; Alonso, Rosa M

    2005-01-01

    A high-performance liquid chromatographic method with diode array detection has been developed and optimized for the separation of five calcium channel blockers belonging to the 1,4-dihydropyridine subgroup (nifedipine and related drugs). The possibility of the simultaneous drug analysis allows a decrease of time during the assay as well as a saving of reagents and solvents. In this work, the effect of four experimental parameters (organic modifier percentage, pH value, concentration of the buffer in the mobile phase, and column temperature) on the chromatographic resolution are investigated by experimental design in order to optimize the chromatographic separation of five 1,4-dihydropyridines (amlodipine, nitrendipine, felodipine, lacidipine, and lercanidipine). Fractional factorial design, central composite design, and finally the Multisimplex program are used to establish the optimal conditions in terms of resolution and minimum analysis time. Optimal separation of the five compounds under study is achieved in less than 12 min using a Sulpecosil LC-ABZ+Plus C18 column, a composition of mobile phase of acetonitrile-10mM acetic acid acetate buffer pH 5 (72:28, v/v) at a flow rate of 1 mL/min, a column temperature of 30 degrees C +/- 0.1 degrees C, and a detection wavelength of 238 nm.

  12. Chromatographic Separation and NMR An Integrated Approach in Pharmaceutical Development.

    PubMed

    Gonnella, Nina C

    2012-01-01

    Over the past 10 years, major improvements in the performance of LC-NMR have been realized. The addition of postcolumn SPE, advances in probe technology including cryogenic probes and microcoil probes, improved solvent suppression pulse sequences, and shielded magnets with better homogeneity have all contributed to rapid advancements in this technology. Application of LC-NMR to problems in pharmaceutical development has had a major impact on structure elucidation studies. LC-NMR has been successfully applied to determine the structures of degradation products, impurities, mixtures of compounds, and metabolites. Use of stop flow techniques with LC-NMR experiments has been a critical means of identifying unstable compounds and studying conformational kinetics. The integration of SPE as an intermediate step between the LC unit and the NMR spectrometer has vastly improved the power of the hyphenated technique in trace analysis applications. Online postcolumn enrichment of chromatographic peaks by SPE dramatically reduces the NMR acquisition times by allowing repeated injections to be trapped onto the same cartridge or different cartridges. Because protonated solvents can be easily removed with a drying procedure, solvents and buffers may be freely chosen for maximizing chromatographic separation without compromising NMR spectral quality. The compound of interest may then be eluted from an SPE cartridge using deuterated organic solvent, which helps to reduce dynamic range issues. When combined with cryogenically cooled microcapillary probes, the sensitivity of the NMR signal increases about 10-fold over conventional room temperature probes, enabling full structure characterization at the microgram level. Heteronuclear experiments with concentrations previously only possible in a limited number of cases have now become standard experiments. The availability of HSQC and HMBC experiments and microcoil/cryogenic technology opens the possibility of using LC-(SPE) NMR for the

  13. Liquid chromatographic separation of antidepressant drugs: I. Tricyclics.

    PubMed

    Beierle, F A; Hubbard, R W

    1983-01-01

    A simple normal-phase (silica), high-performance liquid chromatographic (HPLC) assay of amitriptyline (AMI), doxepin (DOX), imipramine (IMI), nortriptyline (NORT), desmethyldoxepin (DESDOX), desipramine (DESIP), and protriptyline (PRO) in serum with no coelution is described here. Trimipramine and promazine were used as internal standards. Extraction of the 1.0-ml serum samples (collected in plastic) was done with Bond-Elut C18 columns. The compounds of interest were eluted with 10 mM methanolic ammonium acetate. The eluates were evaporated at 56-58 degrees C and reconstituted with 200 microliters of the mobile phase. The mobile phase was absolute ethanol-acetonitrile-tert-butylamine (98:2:0.05, vol/vol/vol). Detection of eluted drugs was at 254 nm at 0.01 absorbance units full scale (AUFS), except for PRO, which was detected at 229 nm at 0.02 AUFS. Absolute recoveries were 87-97%. A 5-micron silica (4.6 X 250 mm) HPLC column was used; results with a 10-micron silica column (3.9 X 300 mm) are also presented. Peak height ratios with trimipramine were linear for each analyte between 25 and 1200 ng/ml. Peak height ratios with promazine as the internal standard were linear for each analyte between 25 and 600 ng/ml. Detection limits under the conditions described were 2 ng/ml for AMI, DOX, and IMI, 4 ng/ml for NORT, DESDOX, and DESIP, and 10 ng/ml for PRO. Coefficients of within-day and day-to-day variation at three concentration levels were less than 9.8% and less than 11.2%, respectively. The hydroxylated metabolites of IMI, DES, NORT, and the cis isomer of DOX are discussed. Steady-state daily dosages and corresponding serum levels are presented for 69 patients. The total assay time was less than 10 min for DESIP and 12 min for PRO. This assay can be used in correlating serum levels with clinical effects, compliancy, and pharmacokinetic studies.

  14. Evolutionary multi-objective optimization based comparison of multi-column chromatographic separation processes for a ternary separation.

    PubMed

    Heinonen, Jari; Kukkonen, Saku; Sainio, Tuomo

    2014-09-05

    Performance characteristics of two advanced multi-column chromatographic separation processes with discontinuous feed, Multi-Column Recycling Chromatogrphy (MCRC) and Japan Organo (JO), were investigated for a ternary separation using multi-objective optimization with an evolutionary algorithm. Conventional batch process was used as a reference. Fractionation of a concentrated acid hydrolysate of wood biomass into sulfuric acid, monosaccharide, and acetic acid fractions was used as a model system. Comparison of the separation processes was based on selected performance parameters in their optimized states. Flow rates and step durations were taken as decision variables whereas the column configuration and dimensions were fixed. The MCRC process was found to be considerably more efficient than the other processes with respect to eluent consumption. The batch process gave the highest productivity and the JO process the lowest. Both of the multi-column processes gave significantly higher monosaccharide yield than the batch process. When eluent consumption and monosaccharide yield are taken into account together with productivity, the MCRC process was found to be the most efficient in the studied case.

  15. Simultaneous acetic acid separation and monosaccharide concentration by reverse osmosis.

    PubMed

    Zhou, Fanglei; Wang, Cunwen; Wei, Jiang

    2013-03-01

    This study aimed to investigate the feasibility and efficiency of simultaneous acetic acid separation and sugar concentration in model lignocellulosic hydrolyzates by reverse osmosis. The effects of operation parameters such as pH, temperature, pressure and feed concentration on the solute retentions were examined with a synthetic xylose–glucose–acetic acid model solution. Results showed that the monosaccharides were almost completely rejected at above 20 bar, while the acetic acid retention increased with the increase in pH and pressure, and decreased with the temperature increase. The maximum separation factors of acetic acid over xylose and glucose reached as high as 211.5 and 228.4 at pH 2.93 (the initial pH of model lignocellulosic hydrolyzates), 40 °C and 20 bar. Furthermore, the concentration and diafiltration process were employed at optimal operation conditions. Consequently, a high sugar concentration and a beneficially lower acetic acid concentration were simultaneously achieved by reverse osmosis.

  16. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  17. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  18. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  19. HIGH PERFORMANCE LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) was obtained on polysaccharide enantioselective HPLC columns using alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, fonofos, fenamiph...

  20. Chromatographic separation and concentration of quercetin and (+)-catechin using mesoporous composites based on MCM-41

    NASA Astrophysics Data System (ADS)

    Karpov, S. I.; Belanova, N. A.; Korabel'nikova, E. O.; Nedosekina, I. V.; Roessner, F.; Selemenev, V. F.

    2015-05-01

    Data on chromatographic separation of quercetin and (+)-catechin-flavonoids with similar physicochemical (including sorption) properties—are presented. The highest efficiency of chromatographic process at high sorption capacity of the material with respect to quercetin and slightly lower capacity for (+)-catechin were observed when silylated composites of ordered MCM-41 type materials were used. The application of acetonitrile as a solvent increased the sorption capacity of the material and can be recommended for separation of related polyphenol substances and their determination using ordered MCM-41 modified with trimethylchlorosilane as a stationary phase in a chromatographic column.

  1. Techniques of preparing plant material for chromatographic separation and analysis.

    PubMed

    Romanik, G; Gilgenast, E; Przyjazny, A; Kamiński, M

    2007-03-10

    This paper discusses preparation techniques of samples of plant material for chromatographic analysis. Individual steps of the procedures used in sample preparation, including sample collection from the environment or from tissue cultures, drying, comminution, homogenization, leaching, extraction, distillation and condensation, analyte enrichment, and obtaining the final extracts for chromatographic analysis are discussed. The techniques most often used for isolation of analytes from homogenized plant material, i.e., Soxhlet extraction, ultrasonic solvent extraction (sonication), accelerated solvent extraction, microwave-assisted extraction, supercritical-fluid extraction, steam distillation, as well as membrane processes are emphasized. Sorptive methods of sample enrichment and removal of interferences, i.e., solid-phase extraction, and solid-phase micro-extraction are also discussed.

  2. Novel chromatographic separation and carbon solid-phase extraction of acetanilide herbicide degradation products.

    PubMed

    Shoemaker, Jody A

    2002-01-01

    One acetamide and 5 acetanilide herbicides are currently registered for use in the United States. Over the past several years, ethanesulfonic acid (ESA) and oxanilic acid (OA) degradation products of these acetanilide/acetamide herbicides have been found in U.S. ground waters and surface waters. Alachlor ESA and other acetanilide degradation products are listed on the U.S. Environmental Protection Agency's (EPA) 1998 Drinking Water Contaminant Candidate List. Consequently, EPA is interested in obtaining national occurrence data for these contaminants in drinking water. EPA currently does not have a method for determining these acetanilide degradation products in drinking water; therefore, a research method is being developed using liquid chromatography/negative ion electrospray/mass spectrometry with solid-phase extraction (SPE). A novel chromatographic separation of the acetochlor/alachlor ESA and OA structural isomers was developed which uses an ammonium acetate-methanol gradient combined with heating the analytical column to 70 degrees C. Twelve acetanilide degradates were extracted by SPE from 100 mL water samples using carbon cartridges with mean recoveries >90% and relative standard deviations < or =16%.

  3. Reversed-phase liquid chromatographic separation and simultaneous profiling of steroidal glycoalkaloids and their aglycones.

    PubMed

    Kuronen, P; Väänänen, T; Pehu, E

    1999-11-19

    Improved and simplified reversed-phase liquid chromatographic conditions for the separation and simultaneous profiling of both steroidal glycoalkaloids and their aglycones, having solanidane- or spirosolane-type structures, are described. The most reproducible retention behavior for these ionizable compounds on C18 columns was achieved under isocratic and gradient elution conditions using acetonitrile in combination with triethylammonium phosphate buffer at pH 3.0, when basic functional groups of solutes and silanol groups on the silica are fully protonated minimizing ionic interactions. Gradient elution was the only feasible approach for the simultaneous separation of steroidal glycoalkaloids and their aglycones. A Zorbax SB C18 column, specially designed for low-pH separations, showed good performance in critical separations. The impurities of the commercial tomatine and tomatidine standards were studied and confirmed using mass spectrometric, liquid chromatographic and thin-layer chromatographic methods.

  4. Improved Chromatographic Separation of Sitagliptin Phosphate and Metformin Hydrochloride

    PubMed Central

    Hendy, Moataz S.

    2015-01-01

    New UPLC method was developed for determination of sitagliptin and metformin using Symmetry C18 column (100 mm × 2.1 mm, 2.2 μm) and isocratic elution (methanol 20%), pH (3.5) as a mobile phase. The ultraviolet detector was operated at 220 nm and the column temperature was 50°C. Linearity parameters were acceptable over the concentration ranges of 2-12 μgml-1 and 5-35 μgml-1 for sitagliptin and metformin, respectively. The variables were premeditated to adjust the chromatographic conditions using design of experiment. The proposed method was proved to be accurate for the quality control of the mentioned drugs in their pharmaceutical dosage form. PMID:26759536

  5. Liquid chromatographic separation of the stereoisomers of thiazide diuretics.

    PubMed

    Hyun, M H; Pirkle, W H

    2000-04-21

    A number of racemic thiazide diuretics and analogues were resolved on two diastereomeric chiral stationary phases (CSPs) prepared from (S)- or (R)-alpha-[1-(6,7-dimethyl)naphthyl]-10-dodecenylamine and (S)-2-phenylpropanoic acid. Of the two diastereomeric CSPs, the (S,S) and the (R,S), the former is found to be better than the latter in separating the enantiomers of the racemic thiazide diuretics and their analogues with complete separation being observed on the (S,S)-CSP. Chiral recognition is controlled principally by the (R)- or (S)-alpha-[1-(6,7-dimethyl)naphthyl]-10-dodecenylamine portion of the CSPs. The second stereogenic center of the CSP provides but secondary effects on the chiral recognition presumably involving, in the case of the (S,S)-CSP, face-to-edge pi-pi interaction between the aromatic ring of the analytes and the phenyl on the second stereogenic center.

  6. Thin-Layer Chromatographic Separation of Phenols: An Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Kurth, Mark J.

    1986-01-01

    Background information, procedures used, and equipment needed are provided for an experiment in which a series of readily available, inexpensive, and relatively nontoxic phenols are separated using thin-layer chromatographic techniques. The experiment permits a discussion of how relative Rf values may be rationalized by considering a molecule's…

  7. Chiral porous organic frameworks for asymmetric heterogeneous catalysis and gas chromatographic separation.

    PubMed

    Dong, Jinqiao; Liu, Yan; Cui, Yong

    2014-12-11

    Three chiral robust diene-based porous organic frameworks (POFs) are prepared. POF- is shown to be an efficient heterogeneous catalyst after metallation for asymmetric conjugation addition with up to 93% ee, and it can also function as a new chiral stationary phase for gas chromatographic separation of racemates.

  8. [Chromatographic separation of activated proteases from human plasma].

    PubMed

    Lehmann, B; Taucher, M; Kühne, H; Scheuch, D W

    1988-01-01

    After separation of aceton and dextran sulfate activated human plasma by column chromatography on DEAE-cellulose three esterolytically and amidolytically active fractions, respectively, were obtained, which were assigned to the following species: plasma kallikrein (PK), PK.alpha-macroglobulin.HMW-Kininogen. Their percentage in the whole activity is variable. The proportion of free PK is low (0.11). For characterization of the products we studied inhibition by different polyvalent inhibitors. The Michaelis constant (Km) with p-toluene-sulfonyl-L-arginine methyl ester (TAME) were determined. For simulation of in vivo conditions dextran sulfate activated plasma was inactivated at 37 degrees C. The residual activity and the spontaneous activity in plasma from patients with shock are produced by different active protease inhibitor complexes.

  9. High-speed counter-current chromatographic separation of phytosterols.

    PubMed

    Schröder, Markus; Vetter, Walter

    2011-07-01

    Phytosterols are bioactive compounds which occur in low concentrations in plant oils. Due to their beneficial effects on human health, phytosterols have already been supplemented to food. Commercial phytosterol standards show insufficient purity and/or are very expensive. In this study, we developed a high-speed counter-current chromatography (HSCCC) method for the fractionation and analysis of a commercial crude β-sitosterol standard (purity ∼60% according to supplier). Different solvent systems were tested in shake-flask experiments, and the system n-hexane/methanol/aqueous silver nitrate solution (34/24/1, v/v/v) was finally used for HSCCC fractionation. About 50 mg phytosterols was injected and distributed into 57 fractions. Selected fractions were condensed and re-injected into the HSCCC system. This measure provided pure sitostanol (>99%) and β-sitosterol (∼99%), as well as a mixture of campesterol and stigmasterol without further phytosterols. An enriched HSCCC fraction facilitated the mass spectrometric analysis of further 11 minor phytosterols (after trimethylsilylation). It was also shown that the commercial product contained about 0.3% carotinoids which eluted without delay into an early HSCCC fraction and which were separated from the phytosterols.

  10. Chromatographic separation as selection process for prebiotic evolution and the origin of the genetic code.

    PubMed

    Lehmann, U

    1985-01-01

    A model for the evolution of a translation apparatus has been suggested where oligonucleotides in a hairpin conformation act as primordial adapters. Specifically activated amino acids are assumed to be attached to these hairpin molecules. For the specific activation, a chromatographic separation of, e.g. ala and CMP from gly and GMP can be accomplished on silica (e.g. of volcanic origin) with aqueous salt solutions. Other adsorbents like clays (kaolin, bentonite, montmorillonite), different silicates (florisil, magnesium trisilicate, calcium silicate, talc), hydroxyapatite, barium sulfate, calcium carbonate, calcium fluoride and titanoxide have been examined as model systems for the separation of nucleotides, nucleosides and amino acids on mineral surfaces. The possible role of chromatographic separation of amino acids for the formation of proteinoids, composed of selected amino acids, is also considered.

  11. Chromatographic enrichment and enantiomer separation of axially chiral polybrominated biphenyls in a technical mixture.

    PubMed

    Berger, Urs; Vetter, Walter; Götsch, Arntraut; Kallenborn, Roland

    2002-10-11

    The separation properties of different chromatographic methods regarding the enantioselective separation of axially chiral (atropisomeric) polybrominated biphenyls (PBB) were studied. For this purpose, the technical hexabromobiphenyl product Firemaster BP-6 was characterised by gas-chromatography coupled to electron capture detection (GC/ECD) and electron-capture negative ion mass spectrometry (GC/ECNI-MS) as well as by liquid chromatographic fractionating on active carbon and celite. Twelve individual PBBs including potential atropisomeric PBBs were isolated from Firemaster BP-6 by reversed-phase high-performance liquid chromatography (HPLC) on three serially coupled octadecylsilane columns. Six of the 12 isolated PBBs (three tri-ortho and di-ortho substituted PBBs, respectively) were separated into atropisomers on a HPLC column containing permethylated beta-cyclodextrin on silica. Moreover, the temperature dependency of the enantiomer separations is discussed. Gas chromatographic enantiomer separation of PBBs is a very demanding task due to high elution temperatures. However, the atropisomers of one tri-ortho substituted PBB congener (PBB 149) could be resolved on a column coated with randomly modified heptakis(6-O-tert.-butyldimethylsilyl-2,3-di-O-methyl)-beta-cyclodextrin in OV 1701.

  12. Ion chromatographic separation of inorganic ions using a combination of hydrophilic interaction chromatographic column and cation-exchange resin column.

    PubMed

    Arai, Kaori; Mori, Masanobu; Hironaga, Takahiro; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-04-01

    A combination of hydrophilic interaction chromatographic (HILIC) column and a weakly acidic cation-exchange resin (WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography (IC). Firstly, the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions. The columns used were SeQuant ZIC-HILIC (ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase (ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase (HILIC-10). When using tartaric acid as the eluent, the HILIC columns indicated strong retentions for anions, based on ion-pair interaction. Especially, HILIC-10 could strongly retain anions compared with ZIC-HILIC. The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I(-) > NO3(-) > Br(-) > Cl(-) > H2PO4(-). However, since HILIC-10 could not separate analyte cations, a WCX column (TSKgel Super IC-A/C) was connected after the HILIC column in series. The combination column system of HILIC and WCX columns could successfully separate ten ions (Na+, NH4+, K+, Mg2+, Ca2+, H2PO4(-), Cl(-), Br(-), NO3(-) and I(-)) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6. The relative standard deviations (RSDs) of analyte ions by the system were in the ranges of 0.02% - 0.05% in retention times and 0.18% - 5.3% in peak areas through three-time successive injections. The limits of detection at signal-to-noise ratio of 3 were 0.24 - 0.30 micromol/L for the cations and 0.31 - 1.2 micromol/L for the anions. This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.

  13. Advances in high-throughput and high-efficiency chiral liquid chromatographic separations.

    PubMed

    Patel, Darshan C; Wahab, M Farooq; Armstrong, Daniel W; Breitbach, Zachary S

    2016-10-07

    The need for improved liquid chromatographic chiral separations has led to the advancement of chiral screening techniques as well as the development of new, high efficiency chiral separation methods and stationary phases. This review covers these advancements, which primarily occurred over the last 15 years. High throughput techniques include multi-column screening units, multiple injection sequences, and fast gradient SFC screening. New separation methods and column technologies that aim at high efficiency chiral separations include the use of achiral UHPLC (i.e. sub-2μm) columns for separating derivatized chiral analytes or using chiral additives in the run buffer, UHPLC chiral stationary phases, and superficially porous particle based chiral stationary phases. Finally, the enhancement of chiral separations through these new technologies requires that certain instrumental considerations be made. Future directions in continuing to improve chiral separations are also discussed.

  14. Chromatographic separation of three monoclonal antibody variants using multicolumn countercurrent solvent gradient purification (MCSGP).

    PubMed

    Müller-Späth, Thomas; Aumann, Lars; Melter, Lena; Ströhlein, Guido; Morbidelli, Massimo

    2008-08-15

    Multicolumn countercurrent solvent gradient purification (MCSGP) is a continuous chromatographic process developed in recent years (Aumann and Morbidelli, 2007a; Aumann et al., 2007) that is particularly suited for applications in the field of bioseparations. Like batch chromatography, MCSGP is suitable for three-fraction chromatographic separations and able to perform solvent gradients but it is superior in terms of solvent consumption, yield, purity, and productivity due to the countercurrent movement of the liquid and the solid phases. In this work, the MCSGP process is applied to the separation of three monoclonal antibody variants on a conventional preparative cation exchange resin. The experimental process performance was compared to simulations based on a lumped kinetic model. Yield and purity values of the target variant of 93%, respectively were obtained experimentally. The batch reference process was clearly outperformed by the MCSGP process.

  15. Chromatographic separation of germanium and arsenic for the production of high purity (77)As.

    PubMed

    Gott, Matthew D; DeGraffenreid, Anthony J; Feng, Yutian; Phipps, Michael D; Wycoff, Donald E; Embree, Mary F; Cutler, Cathy S; Ketring, Alan R; Jurisson, Silvia S

    2016-04-08

    A simple column chromatographic method was developed to isolate (77)As (94±6% (EtOH/HCl); 74±11 (MeOH)) from germanium for potential use in radioimmunotherapy. The separation of arsenic from germanium was based on their relative affinities for different chromatographic materials in aqueous and organic environments. Using an organic or mixed mobile phase, germanium was selectively retained on a silica gel column as germanate, while arsenic was eluted from the column as arsenate. Subsequently, enriched (76)Ge (98±2) was recovered for reuse by elution with aqueous solution (neutral to basic). Greater than 98% radiolabeling yield of a (77)As-trithiol was observed from methanol separated [(77)As]arsenate [17].

  16. Intact protein separation by chromatographic and/or electrophoretic techniques for top-down proteomics.

    PubMed

    Capriotti, Anna Laura; Cavaliere, Chiara; Foglia, Patrizia; Samperi, Roberto; Laganà, Aldo

    2011-12-09

    Mass spectrometry used in combination with a wide variety of separation methods is the principal methodology for proteomics. In bottom-up approach, proteins are cleaved with a specific proteolytic enzyme, followed by peptide separation and MS identification. In top-down approach intact proteins are introduced into the mass spectrometer. The ions generated by electrospray ionization are then subjected to gas-phase separation, fragmentation, fragment separation, and automated interpretation of mass spectrometric and chromatographic data yielding both the molecular weight of the intact protein and the protein fragmentation pattern. This approach requires high accuracy mass measurement analysers capable of separating the multi-charged isotopic cluster of proteins, such as hybrid ion trap-Fourier transform instruments (LTQ-FTICR, LTQ-Orbitrap). Front-end separation technologies tailored for proteins are of primary importance to implement top-down proteomics. This review intends to provide the state of art of protein chromatographic and electrophoretic separation methods suitable for MS coupling, and to illustrate both monodimensional and multidimensional approaches used for LC-MS top-down proteomics. In addition, some recent progresses in protein chromatography that may provide an alternative to those currently employed are also discussed.

  17. Continuous countercurrent chromatographic separator for the purification of sugars from biomass hydrolyzate. Final project report, July 1, 1996--September 30, 1997

    SciTech Connect

    Wooley, R J

    1997-12-01

    Production of pure sugars is required to enable production of fuels and chemicals from biomass feedstocks. Hydrolysis of cellulose and hemicellulose (principal constituents of biomass) produces sugars that can be utilized in various fermentation process to produce valuable chemicals. Unfortunately, the hydrolysis process also liberates chemicals from the biomass that can be toxic to the fermenting organisms. The two primary toxic components of biomass hydrolyzate are sulfuric acid (catalyst used in the hydrolysis) and acetic acid (a component of the feed biomass). In the standard batch chromatographic separation of these three components, sugar elutes in the middle. Batch chromatographic separations are not practical on a commercial scale, because of excess dilution and high capital costs. Because sugar is the {open_quotes}center product,{close_quotes} a continuous separation would require two costly binary separators. However, a single, slightly larger separator, configured to produce three products, would be more economical. This FIRST project develops a cost-effective method for purifying biomass hydrolyzate into fermentable sugars using a single continuous countercurrent separator to separate this ternary mixture.

  18. Application of Sigmoidal Transformation Functions in Optimization of Micellar Liquid Chromatographic Separation of Six Quinolone Antibiotics.

    PubMed

    Hadjmohammadi, Mohammadreza; Salary, Mina

    2016-03-01

    A chemometrics approach has been used to optimize the separation of six quinolone compounds by micellar liquid chromatography (MLC). A Derringer's desirability function, a multicriteria decision-making (MCDM) method, was tested for evaluation of two different measures of chromatographic performance (resolution and analysis time). The effect of three experimental parameters on a chromatographic response function (CRF) expressed as a product of two sigmoidal desirability functions was investigated. The sigmoidal functions were used to transform the optimization criteria, resolution and analysis time into the desirability values. The factors studied were the concentration of sodium dodecyl sulfate, butanol content and pH of the mobile phase. The experiments were done according to the face-centered cube central composite design, and the calculated CRF values were fitted to a polynomial model to correlate the CRF values with the variables and their interactions. The developed regression model showed good descriptive and predictive ability (R(2) = 0.815, F = 6.919, SE = 0.038, [Formula: see text]) and used, by a grid search algorithm, to optimize the chromatographic conditions for the separation of the mixture. The efficiency of prediction of polynomial model was confirmed by performing the experiment under the optimal conditions.

  19. Liquid chromatographic separation in metal-organic framework MIL-101: a molecular simulation study.

    PubMed

    Hu, Zhongqiao; Chen, Yifei; Jiang, Jianwen

    2013-02-05

    A molecular simulation study is reported to investigate liquid chromatographic separation in metal-organic framework MIL-101. Two mixtures are considered: three amino acids (Arg, Phe, and Trp) in aqueous solution and three xylene isomers (p-, m-, and o-xylene) dissolved in hexane. For the first mixture, the elution order is found to be Arg > Phe > Trp. The hydrophilic Arg has the strongest interaction with the polar mobile phase (water) and the weakest interaction with the stationary phase (MIL-101), and thus transports at the fastest velocity. Furthermore, Arg forms the largest number of hydrogen bonds with water and possesses the largest hydrophilic solvent-accessible surface area. For the second mixture, the elution order is p-xylene > m-xylene > o-xylene, consistent with available experimental observation. With the largest polarity as compared to p- and m-xylenes, o-xylene interacts the most strongly with the stationary phase and exhibits the slowest transport velocity. For both mixtures, the underlying separation mechanism is elucidated from detailed energetic and structural analysis. It is revealed that the separation can be attributed to the cooperative solute-solvent and solute-framework interactions. This simulation study, for the first time, provides molecular insight into liquid chromatographic separation in a MOF and suggests that MIL-101 might be an interesting material for the separation of industrially important liquid mixtures.

  20. Superheated water as chromatographic eluent for parabens separation on octadecyl coated zirconia stationary phase.

    PubMed

    Dugo, Paola; Buonasera, Katia; Crupi, Maria Lucia; Cacciola, Francesco; Dugo, Giovanni; Mondello, Luigi

    2007-05-01

    In this study, the use of pure water at superheated temperatures, between 100 and 200 degrees C, as a mobile phase for RP separation is explored. Instrumental parameters, such as temperature, flow rate, preheating and cooling, have shown significant effects on the quality of the chromatographic peaks. The properties of superheated water as an eluent were investigated by observing the chromatographic behaviour of four parabens on a carbon-clad zirconia (ZR) phase with covalently bonded octadecyl groups. Results were compared with those obtained at 30 degrees C on a silica-based phase with octadecyl groups, using water and ACN as mobile phase. The optimized method was finally applied to analyse parabens in a commercial body cream.

  1. Chemometric approach for development, optimization, and validation of different chromatographic methods for separation of opium alkaloids.

    PubMed

    Acevska, J; Stefkov, G; Petkovska, R; Kulevanova, S; Dimitrovska, A

    2012-05-01

    The excessive and continuously growing interest in the simultaneous determination of poppy alkaloids imposes the development and optimization of convenient high-throughput methods for the assessment of the qualitative and quantitative profile of alkaloids in poppy straw. Systematic optimization of two chromatographic methods (gas chromatography (GC)/flame ionization detector (FID)/mass spectrometry (MS) and reversed-phase (RP)-high-performance liquid chromatography (HPLC)/diode array detector (DAD)) for the separation of alkaloids from Papaver somniferum L. (Papaveraceae) was carried out. The effects of various conditions on the predefined chromatographic descriptors were investigated using chemometrics. A full factorial linear design of experiments for determining the relationship between chromatographic conditions and the retention behavior of the analytes was used. Central composite circumscribed design was utilized for the final method optimization. By conducting the optimization of the methods in very rational manner, a great deal of excessive and unproductive laboratory research work was avoided. The developed chromatographic methods were validated and compared in line with the resolving power, sensitivity, accuracy, speed, cost, ecological aspects, and compatibility with the poppy straw extraction procedure. The separation of the opium alkaloids using the GC/FID/MS method was achieved within 10 min, avoiding any derivatization step. This method has a stronger resolving power, shorter analysis time, better cost/effectiveness factor than the RP-HPLC/DAD method and is in line with the "green trend" of the analysis. The RP-HPLC/DAD method on the other hand displayed better sensitivity for all tested alkaloids. The proposed methods provide both fast screening and an accurate content assessment of the six alkaloids in the poppy samples obtained from the selection program of Papaver strains.

  2. Liquid Chromatographic Separation and Thermodynamic Investigation of Mirabegron Enantiomers on a Chiralpak AY-H Column.

    PubMed

    Zhou, Fan; Zhou, Yuxia; Zou, Qiaogen; Sun, Lili; Wei, Ping

    2015-09-01

    Liquid chromatographic separation of mirabegron enantiomers on Chiralpak AY-H, a column coated with amylose tris-(5-chloro-2-methylphenylcarbamate) as a chiral stationary phase, was studied under normal phase conditions. The influence of ethanol content (30-45%) and column temperature (20-40°C) on retention, resolution and separation were evaluated. Apparent thermodynamic parameters deduced from Van't Hoff plots were used to understand chiral separation mechanisms, and the chiral separation was enthalpy driven. The optimized chromatographic conditions were using a mixture solution of n-hexane, ethanol and diethyl amine (55 : 45 : 0.1, v/v/v) as a mobile phase at a flow rate of 1.0 mL/min. The column temperature and UV detector were set at 35°C and 254 nm, respectively. The method was validated to be simple, accuracy, sensitive and robust according to the ICH guidelines, and it was suitable for the routine quality control of mirabegron enantiomers for pharmaceutical industries.

  3. LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF TRANS-CHLORDANE, CIS-CHLORDANE, HEPTACHLOR, HEPTACHLOR EPOXIDE AND ALPHA-HEXACHLOROCYCLOHEXANE WITH APPLICATION TO SMALL-SCALE PREPARATIVE SEPARATION

    EPA Science Inventory

    Analytical high-performance liquid chromatographic separations of the individual enantiomers of five polychlorinated compounds were obtained on polysaccharide stereoselective HPLC columns. The enantiomers of the pesticides trans-chlordane, cis-chlordane and heptachlor were separa...

  4. A trade off between separation, detection and sustainability in liquid chromatographic fingerprinting.

    PubMed

    Funari, Cristiano S; Carneiro, Renato L; Cavalheiro, Alberto J; Hilder, Emily F

    2014-08-08

    It is now recognized that analytical chemistry must also be a target for green principles, in particular chromatographic methods which typically use relatively large volumes of hazardous organic solvents. More generally, high performance liquid chromatography (HPLC) is employed routinely for quality control of complex mixtures in various industries. Acetonitrile and methanol are the most commonly used organic solvents in HPLC, but they generate an impact on the environment and can have a negative effect on the health of analysts. Ethanol offers an exciting alternative as a less toxic, biodegradable solvent for HPLC. In this work we demonstrate that replacement of acetonitrile with ethanol as the organic modifier for HPLC can be achieved without significantly compromising analytical performance. This general approach is demonstrated through the specific example analysis of a complex plant extract. A benchmark method employing acetonitrile for the analysis of Bidens pilosa extract was statistically optimized using the Green Chromatographic Fingerprinting Response (GCFR) which includes factors relating to separation performance and environmental parameters. Methods employing ethanol at 30 and 80°C were developed and compared with the reference method regarding their performance of separation (GCFR) as well as by a new metric, Comprehensive Metric to Compare Liquid Chromatography Methods (CM). The fingerprint with ethanol at 80°C was similar to or better than that with MeCN according to GCFR and CM. This demonstrates that temperature may be used to replace harmful solvents with greener ones in HPLC, including for solvents with significantly different physiochemical properties and without loss in separation performance. This work offers a general approach for the chromatographic analysis of complex samples without compromising green analytical chemistry principles.

  5. Gas Chromatographic Separation of an Acetylene Vinyl Fluoride-Difluoroethane Mixture on Triethylene Glycol and Silicone Oil,

    DTIC Science & Technology

    The purpose of the research was to study gas-chromatographic separation of impurities of acetylene and difluoroethane in vinyl fluoride obtained by...and difluoroethane . All the components are separated, and the criteria of separation of acetylene-vinyl fluoride and vinyl fluoride- difluoroethane

  6. [Development of online conventional array-based two-dimensional liquid chromatographic system for proteins separation in human plasma].

    PubMed

    Huang, Zhi; Hong, Guangfeng; Gao, Mingxia; Zhang, Xiangmin

    2014-04-01

    Human plasma is one of the proteins-containing samples most difficult to characterize on account of the wide dynamic concentration range of its intact proteins. Herein, we developed a high-throughput conventional array-based two-dimensional liquid chromatographic system for proteins separation in human plasma in online mode. In the system, a conventional strong-anion exchange chromatographic column was used as the first separation dimension and eight parallel conventional reversed-phase liquid chromatographic columns were integrated as the second separation dimension. The fractions from the first dimension were sequentially transferred into the corresponding reversed-phase liquid chromatographic precolumns for retention and enrichment using a 10-port electrically actuated multi-position valve. The second dimensional solvent flow was directly and identically split into 8 channels. The fractions were concurrently back-flushed from the precolumns into the 8 conventional RP columns and were separated simultaneously. An 8-channel fraction collector was refitted to collect the reversed-phase liquid chromatographic fractions for further investigation. Bicinchoninic acid (BCA) dyein solution was conveniently used for high-abundance protein location. Two separation dimensions were relatively independent parts, as well as each channel of the second dimensional array separation. Therefore, the new system could improve the separation throughput and total peak capacity. The system was successfully applied for the separation of human plasma intact proteins. The results indicated the established system is an effective method for removing high abundance proteins in plasma and in-depth research in plasma proteomics.

  7. Clickable Periodic Mesoporous Organosilica Monolith for Highly Efficient Capillary Chromatographic Separation.

    PubMed

    Wu, Ci; Liang, Yu; Yang, Kaiguang; Min, Yi; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2016-02-02

    A novel clickable periodic mesoporous organosilica monolith with the surface area up to 1707 m(2) g(-1) was in situ synthesized in the capillary by the one-step condensation of the organobridged-bonded alkoxysilane precursor bis(triethoxysilyl)ethylene. With Si-C bonds in the skeleton, the monolith possesses excellent chemical and mechanical stability. With vinyl groups highly loaded and homogeneously distributed throughout the structure, the monolith can be readily functionalized with functional groups by effective thiol-ene "click" chemistry reaction. Herein, with "click" modification of C18, the obtained monolith was successfully applied for capillary liquid chromatographic separation of small molecules and proteins. The column efficiency could reach 148,000 N/m, higher than most reported hybrid monoliths. Moreover, intact proteins could be separated well with good reproducibility, even after the monolithic column was exposed by basic mobile phase (pH 10.0) overnight, demonstrating the great promising of such monolith for capillary chromatographic separation.

  8. Extraction chromatographic separations of tantalum and tungsten from hafnium and complex matrix constituents.

    PubMed

    Snow, Mathew S; Finck, Martha R; Carney, Kevin P; Morrison, Samuel S

    2017-02-10

    Tantalum (Ta), hafnium (Hf), and tungsten (W) analyses from complex matrices require high purification of these analytes from each other and major/trace matrix constituents, however, current state-of-the-art Ta/Hf/W separations rely on traditional anion exchange approaches that show relatively similar distribution coefficient (Kd) values for each element. This work reports an assessment of three commercially available extraction chromatographic resins (TEVA, TRU, and UTEVA) for Ta/Hf/W separations. Batch contact studies show differences in Ta/Hf and Ta/W Kd values of up to 10(6) and 10(4) (respectively), representing an improvement of a factor of 100 and 300 in Ta/Hf and Ta/W Kd values (respectively) over AG1×4 resin. Variations in the Kd values as a function of HCl concentration for TRU resin show that this resin is well suited for Ta/Hf/W separations, with Ta/Hf, Ta/W, and W/Hf Kd value improvements of 10, 200, and 30 (respectively) over AG1×4 resin. Analyses of digested soil samples (NIST 2710a) using TRU resin and tandem TEVA-TRU columns demonstrate the ability to achieve extremely high purification (>99%) of Ta and W from each other and Hf, as well as enabling very high purification of Ta and W from the major and trace elemental constituents present in soils using a single chromatographic step.

  9. Electrochemical stabilization of transplutonium-element valence states under chromatographic separation conditions

    SciTech Connect

    Kosyakov, V.N.; Yakovlev, N.G.; Vlasov, M.M.

    1987-03-01

    The example of separating berkelium and trivalent transplutonium elements (TPE) is considered for an extraction-chromatographic system containing 4 mole/liter HNO/sub 3/ with D2EHPA, which demonstrates the scope for electrochemical stabilization of valency states. The carrier for the stationary organic phase was a corrosion-resistant conducting material of large surface area (ground vitrocarbon, graphitized carbon fiber, etc.), which at the same time was the working electrode in an electrochemical cell supplied with the appropriate potential. The method does not require the addition of oxidizing or reducing agents and allows remote control.

  10. Extraction chromatographic separation of promethium from high active waste solutions of Purex origin

    SciTech Connect

    Ramanujam, A.; Achuthan, P.V.; Dhami, P.S.; Gopalakrishnan, V.; Kannan, R.; Mathur, J.N.

    1995-03-01

    An extraction chromatographic procedure for the separation of {sup 147}Pm from High Active Waste solutions of Purex process has been developed. Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO) and 2-ethylhexyl-2-ethylhexylphosphonic acid (KSM-17), both sorbed separately on an inert support(chromosorb-102) have been sequentially employed for this purpose. In the CMPO column, the rare earths and the trivalent actinides are sorbed together with uranium, plutonium and traces of few other fission products. The elution of this column with 0.04 M HNO{sub 3} gives an eluate containing trivalent actinides and lanthanides. This solution, after adjusting the pH to 2.0, is used as feed for the second extraction chromatographic column based on KSM-17. All the trivalent metal ions are sorbed on the column leaving the trace impurities in the effluent. Fractional elution of the metal ions from this column is carried out with nitric acid of varying concentrations. At 0.09 M HNO{sub 3}, the pure beta emitting fraction of {sup 147}Pm has been obtained. 16 refs., 3 figs., 2 tabs.

  11. Remotely detected NMR for the characterization of flow and fast chromatographic separations using organic polymer monoliths.

    PubMed

    Teisseyre, Thomas Z; Urban, Jiri; Halpern-Manners, Nicholas W; Chambers, Stuart D; Bajaj, Vikram S; Svec, Frantisek; Pines, Alexander

    2011-08-01

    An application of remotely detected magnetic resonance imaging is demonstrated for the characterization of flow and the detection of fast, small molecule separations within hypercrosslinked polymer monoliths. The hyper-cross-linked monoliths exhibited excellent ruggedness, with a transit time relative standard deviation of less than 2.1%, even after more than 300 column volumes were pumped through at high pressure and flow. Magnetic resonance imaging enabled high-resolution intensity and velocity-encoded images of mobile phase flow through the monolith. The images confirm that the presence of a polymer monolith within the capillary disrupts the parabolic laminar flow profile that is characteristic of mobile phase flow within an open tube. As a result, the mobile phase and analytes are equally distributed in the radial direction throughout the monolith. Also, in-line monitoring of chromatographic separations of small molecules at high flow rates is shown. The coupling of monolithic chromatography columns and NMR provides both real-time peak detection and chemical shift information for small aromatic molecules. These experiments demonstrate the unique power of magnetic resonance, both direct and remote, in studying chromatographic processes.

  12. Dried calcium alginate/magnetite spheres: a new support for chromatographic separations and enzyme immobilization

    SciTech Connect

    Burns, M.A.; Kvesitadze, G.I.; Graves, D.J.

    1985-02-01

    Dried spheres made from an alginate solution containing magnetite particles have excellent potential as a support for enzyme immobilization and chromatographic applications. The beads were found to be much stronger than gels such as polyacrylamide and dextran, indicating that high flow rates and pressures could be used in column separations. The support withstood not only temperatures of up to 120/sup 0/C, but also most pH values and common solvents. While some solutions, such as phosphate buffers, dissolved the spheres, stabilization with Tyzor TE eliminated this problem. The physical properties of the beads include a glasslike density of 2.2 g/mL, excellent sphericity, low porosity, and a narrow size distribution. The magnetite present in the support allows the beads to be used for magnetic separations such as high gradient magnetic filtration. Their high degree of microroughness provides a large exposed surface area for enzyme and ligand binding. Mixed Actinomyces fradiae proteases and Aspergillus niger ..cap alpha..-amylase, two enzymes representative of classes which attack large substrates, were immobilized on the bead's surface with high activity and stability. A cyanuric dye which can be used in chromatographic applications (Cibacron Blue F3GA) was also readily coupled to the surface of this support with good yield.

  13. Novel behavior of the chromatographic separation of linear and cyclic polymers

    PubMed Central

    Montenegro-Burke, J. Rafael; Bennett, Jackson M.; McLean, John A.; Hercules, David M.

    2016-01-01

    In various polymerization processes, the formation of a wide variety of chains, not only in length but also in chemical composition, broadly complicates comprehensive polymer characterization. In this communication, we compare different stationary and mobile phases for the analysis of complex polymer mixtures via size-exclusion chromatography-mass spectrometry (SEC-MS). To the best of our knowledge, we report novel chromatographic effects for the separation of linear and cyclic oligomers for polyesters (PE) and polyurethanes (PUR). A complete separation for the different structures was achieved for both polymer types with a single solvent system (ACN) and without extensive optimization. Additionally, cyclic species were found to show an inverse elution profile compared to their linear counterparts, suggesting distinct physical properties between species. PMID:26637218

  14. Ion chromatographic separation and determination of phosphate and arsenate in water and hair.

    PubMed

    Antony, P J; Karthikeyan, S; Iyer, C S P

    2002-02-15

    A simple and sensitive method for the sequential determination of phosphate and arsenate was developed based on initial ion chromatographic separation followed by detection as the ion-association complex formed by heteropolymolybdophosphate and arsenate with bismuth. With 200 microl sample injection and separation on a AS4A-SC column using an eluent of 3.5 mM sodium hydrogen carbonate-10.0 mM sodium hydroxide, the detection limits which are calculated as the concentration equivalent to twice the baseline noise, were found to be 0.8 microg/l and 4.2 microg/l for P and As, respectively. Spiked samples were analyzed and recoveries were found to be satisfactory in the range of 95-105% for phosphate and 90-105% for arsenate. Samples of water and hair were analyzed by the proposed method.

  15. Evaluation of the separation performance of polyvinylpyrrolidone as a virtual stationary phase for chromatographic NMR.

    PubMed

    Huang, Shaohua; Wu, Rui; Bai, Zhengwu; Yang, Ying; Li, Suying; Dou, Xiaowei

    2014-09-01

    Polyvinylpyrrolidone (PVP) was used as a virtual stationary phase to separate p-xylene, benzyl alcohol, and p-methylphenol by the chromatographic NMR technique. The effects of concentration and weight-average molecular weight (Mw) of PVP, solvent viscosity, solvent polarity, and sample temperature on the resolution of these components were investigated. It was found that both higher PVP concentration and higher PVP Mw caused the increase of diffusion resolution for the three components. Moreover, the diffusion resolution did not change at viscosity-higher solvents. Moreover, the three components showed different resolution at different solvents. As temperature increased, the diffusion resolution between p-xylene and benzyl alcohol gradually increased, and the one between p-xylene and p-methylphenol slightly increased from 278 to 298 K and then decreased above 298 K. It was also found that the polarity of the analytes played an important role for the separation by affecting the diffusion coefficient.

  16. Chromatographic separation of vanadium, tungsten and molybdenum with a liquid anion-exchanger.

    PubMed

    Fritz, J S; Topping, J J

    1971-09-01

    In acidic solution only molybdenum(VI), tungsten(VI), vanadium(V), niobium(V) and tantalum(V) form stable, anionic complexes with dilute hydrogen peroxide. This fact has been used in developing an analytical method of separating molybdenum(VI), tungsten(VI) and vanadium(V) from other metal ions and from each other. Preliminary investigations using reversed-phase paper chromatography and solvent extraction led to a reversed-phase column Chromatographic separation technique. These metal-peroxy anions are retained by a column containing a liquid anion-exchanger (General Mills Aliquat 336) in a solid support. Then molybdenum(VI), tungsten(VI) and vanadium(V) are selectively eluted with aqueous solutions containing dilute hydrogen peroxide and varying concentrations of sulphuric acid.

  17. Liquid chromatographic method for determination of water in soils and the optimization of anion separations by capillary zone electrophoresis

    SciTech Connect

    Benz, N.

    1994-10-01

    A liquid chromatographic method for the determination of water in soil or clay samples is presented. In a separate study, the optimization of electrophoretic separation of alkylated phenolate ions was optimized by varying the pH and acetonitrile concentration of the buffer solutions.

  18. Uniaxially aligned electrospun cellulose acetate nanofibers for thin layer chromatographic screening of hydroquinone and retinoic acid adulterated in cosmetics.

    PubMed

    Tidjarat, Siripran; Winotapun, Weerapath; Opanasopit, Praneet; Ngawhirunpat, Tanasait; Rojanarata, Theerasak

    2014-11-07

    Uniaxially aligned cellulose acetate (CA) nanofibers were successfully fabricated by electrospinning and applied to use as stationary phase for thin layer chromatography. The control of alignment was achieved by using a drum collector rotating at a high speed of 6000 rpm. Spin time of 6h was used to produce the fiber thickness of about 10 μm which was adequate for good separation. Without any chemical modification after the electrospinning process, CA nanofibers could be readily devised for screening hydroquinone (HQ) and retinoic acid (RA) adulterated in cosmetics using the mobile phase consisting of 65:35:2.5 methanol/water/acetic acid. It was found that the separation run on the aligned nanofibers over a distance of 5 cm took less than 15 min which was two to three times faster than that on the non-aligned ones. On the aligned nanofibers, the masses of HQ and RA which could be visualized were 10 and 25 ng, respectively, which were two times lower than those on the non-aligned CA fibers and five times lower than those on conventional silica plates due to the appearance of darker and sharper of spots on the aligned nanofibers. Furthermore, the proposed method efficiently resolved HQ from RA and ingredients commonly found in cosmetic creams. Due to the satisfactory analytical performance, facile and inexpensive production process, uniaxially aligned electrospun CA nanofibers are promising alternative media for planar chromatography.

  19. Graphitic carbon nitride as high-resolution stationary phase for gas chromatographic separations.

    PubMed

    Zheng, Yunzhong; Qi, Meiling; Fu, Ruonong

    2016-07-08

    This work presents the first example of utilization of graphitic carbon nitride (g-C3N4) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated g-C3N4 column showed the column efficiencies of 3760 plates/m and weak polarity. Its resolving capability and retention behaviours were investigated by using the Grob test mixture, and mixtures of diverse types of analytes, and structural and positional isomers. The results showed superior separation performance of the g-C3N4 stationary phase for some critical analytes and preferential retention for aromatic analytes. Specifically, it exhibited high-resolution capability for aromatic and aliphatic isomers such as methylnaphthalenes and dimethylnaphthalenes, phenanthrene and anthracene and alkane isomers. In addition, g-C3N4 column showed excellent thermal stability up to 280°C and good repeatability with relative standard deviation (RSD) values less than 0.09% for intra-day, below 0.23% for inter-day and in the range of 1.9-8.4% for between-column, respectively. The advantageous separation performance shows the potential of g-C3N4 and related materials as stationary phase in GC and other separation technologies.

  20. Utilization of a diol-stationary phase column in ion chromatographic separation of inorganic anions.

    PubMed

    Arai, Kaori; Mori, Masanobu; Kozaki, Daisuke; Nakatani, Nobutake; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-12-28

    We describe the ion chromatographic separation of inorganic anions using a diol-stationary phase column (-CH(OH)CH(2)OH; diol-column) without charged functional groups. Anions were separated using acidic eluent as in typical anion-exchange chromatography. The retention volumes of anions on the diol-column increased with increasing H(+) concentration in the eluent. The anion-exchange capacities of diol-columns in the acidic eluent (pH 2.8) were larger than that of zwitterionic stationary phase column but smaller than that of an anion-exchange column. The separation of anions using the diol-column was strongly affected by the interaction of H(+) ions with the diol-functional groups and by the types of the eluents. In particular, the selection of the eluent was very important for controlling the retention time and resolution. Good separation was obtained using a diol-column (HILIC-10) with 5 mM phthalic acid as eluent. The limits of detection at a signal-to-noise ratio of 3 ranged from 1.2 to 2.7 μM with relative standard deviations (RSD, n=5) of 0.04-0.07% for the retention time and 0.4-2.0% for the peak areas. This method was successfully applied to the determination of H(2)PO(4)(-), Cl(-), and NO(3)(-) in a liquid fertilizer sample.

  1. Thin-layer chromatographic (TLC) separations and bioassays of plant extracts to identify antimicrobial compounds.

    PubMed

    Kagan, Isabelle A; Flythe, Michael D

    2014-03-27

    A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungi or bacteria in broth or agar), allowing time for the microbes to grow in a humid environment, and visualizing zones with no microbial growth. The effectiveness of this screening method, known as bioautography, depends on both the quality of the chromatographic separation and the care taken with microbial culture conditions. This paper describes standard protocols for TLC and contact bioautography with a novel application to amino acid-fermenting bacteria. The extract is separated on flexible (aluminum-backed) silica TLC plates, and bands are visualized under ultraviolet (UV) light. Zones are cut out and incubated face down onto agar inoculated with the test microorganism. Inhibitory bands are visualized by staining the agar plates with tetrazolium red. The method is applied to the separation of red clover (Trifolium pratense cv. Kenland) phenolic compounds and their screening for activity against Clostridium sticklandii, a hyper ammonia-producing bacterium (HAB) that is native to the bovine rumen. The TLC methods apply to many types of plant extracts and other bacterial species (aerobic or anaerobic), as well as fungi, can be used as test organisms if culture conditions are modified to fit the growth requirements of the species.

  2. Ionic liquids in chromatographic and electrophoretic techniques: toward additional improvements in the separation of natural compounds

    PubMed Central

    Freire, Carmen S. R.; Coutinho, João A. P.; Silvestre, Armando J. D.; Freire, Mara G.

    2016-01-01

    Due to their unique properties, in recent years, ionic liquids (ILs) have been largely investigated in the field of analytical chemistry. Particularly during the last sixteen years, they have been successfully applied in the chromatographic and electrophoretic analysis of value-added compounds extracted from biomass. Considering the growing interest in the use of ILs in this field, this critical review provides a comprehensive overview on the improvements achieved using ILs as constituents of mobile or stationary phases in analytical techniques, namely in capillary electrophoresis and its different modes, in high performance liquid chromatography, and in gas chromatography, for the separation and analysis of natural compounds. The impact of the IL chemical structure and the influence of secondary parameters, such as the IL concentration, temperature, pH, voltage and analysis time (when applied), are also critically addressed regarding the achieved separation improvements. Major conclusions on the role of ILs in the separation mechanisms and the performance of these techniques in terms of efficiency, resolution and selectivity are provided. Based on a critical analysis of all published results, some target-oriented ILs are suggested. Finally, current drawbacks and future challenges in the field are highlighted. In particular, the design and use of more benign and effective ILs as well as the development of integrated (and thus more sustainable) extraction–separation processes using IL aqueous solutions are suggested within a green chemistry perspective. PMID:27667965

  3. Ionic liquids in chromatographic and electrophoretic techniques: toward additional improvements in the separation of natural compounds.

    PubMed

    Soares, Belinda; Passos, Helena; Freire, Carmen S R; Coutinho, João A P; Silvestre, Armando J D; Freire, Mara G

    2016-09-07

    Due to their unique properties, in recent years, ionic liquids (ILs) have been largely investigated in the field of analytical chemistry. Particularly during the last sixteen years, they have been successfully applied in the chromatographic and electrophoretic analysis of value-added compounds extracted from biomass. Considering the growing interest in the use of ILs in this field, this critical review provides a comprehensive overview on the improvements achieved using ILs as constituents of mobile or stationary phases in analytical techniques, namely in capillary electrophoresis and its different modes, in high performance liquid chromatography, and in gas chromatography, for the separation and analysis of natural compounds. The impact of the IL chemical structure and the influence of secondary parameters, such as the IL concentration, temperature, pH, voltage and analysis time (when applied), are also critically addressed regarding the achieved separation improvements. Major conclusions on the role of ILs in the separation mechanisms and the performance of these techniques in terms of efficiency, resolution and selectivity are provided. Based on a critical analysis of all published results, some target-oriented ILs are suggested. Finally, current drawbacks and future challenges in the field are highlighted. In particular, the design and use of more benign and effective ILs as well as the development of integrated (and thus more sustainable) extraction-separation processes using IL aqueous solutions are suggested within a green chemistry perspective.

  4. Kinetics and equilibria of the chromatographic separation of maltose and trehalose.

    PubMed

    He, Dengjun; Zhou, Jiachun; Xia, Quanming; Jiang, Lihua; Qiu, Yongjun; Zhao, Liming

    2015-07-01

    Trehalose, a nonreducing disaccharide, has been extensively applied to food, cosmetics, and pharmaceutical goods. The resultant solution of trehalose prepared by enzymatic methods includes high amounts of maltose. However, it is quite difficult to separate maltose and trehalose on an industrial scale because of their similar properties. In this paper, a high-performance resin was selected as a stationary phase to separate trehalose and maltose, and the resolution of these sugars was 0.59. The potential of a cation exchange resin was investigated as the stationary phase in separating trehalose and maltose using deionized water as the mobile phase. Based on the equilibrium dispersive model, the axial dispersion coefficients and overall mass transfer coefficients of maltose and trehalose were determined by moment analysis at two different temperatures, 50 and 70°C. Other parameters, including the column void and the adsorption isotherms, were also determined and applied to simulate the elution curves of trehalose and maltose. The simulated results matched the experimental data, validating the parameters. The optimized parameters are critical to the chromatographic separation of trehalose and maltose on an industrial scale.

  5. Separative analyses of a chromatographic column packed with a core-shell adsorbent for lithium isotope separation

    SciTech Connect

    Sugiyama, T.; Sugura, K.; Enokida, Y.; Yamamoto, I.

    2015-03-15

    Lithium-6 is used as a blanket material for sufficient tritium production in DT fueled fusion reactors. A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites. A model was developed and concentration profiles and time variation in the column were numerically simulated. It became clear that core-shell type adsorbents with thin porous shell were saturated rapidly relatively to fully porous one and established a sharp edge of adsorption band. This is very important feature because lithium isotope separation requires long-distance development of adsorption band. The values of HETP (Height Equivalent of a Theoretical Plate) for core-shell adsorbent packed column were estimated by statistical moments of the step response curve. The value of HETP decreased with the thickness of the porous shell. A core-shell type adsorbent is, then, useful for lithium isotope separation. (authors)

  6. Chromatographic cation exchange separation of decigram quantities of californium and other transplutonium elements

    SciTech Connect

    Benker, D.E.; Chattin, F.R.; Collins, E.D.; Knauer, J.B.; Orr, P.B.; Ross, R.G.; Wiggins, J.T.

    1981-01-01

    Decigram quantities of highly radioactive transplutonium elements are routinely partitioned at TRU by chromatographic elution from cation resin using AHIB eluents. Batch runs containing up to 200 mg of /sup 252/Cf can be made in about 5 h (2 h to load the feed and 3 h for the elution), with two high-pressure ion exchange columns, a small one for the initial loading of the feed and a large one for the elution. The separations achieved in the column are preserved by routing the column effluent through an alpha detector and using the response from the detector to select appropriate product fractions. The high-pressure ion exchange process has been reliable and relatively easy to operate; therefore it will continue to be used for partitioning transplutonium elements at TRU. 3 figures, 1 table.

  7. Scaleable production and separation of fermentation-derived acetic acid. Final CRADA report.

    SciTech Connect

    Snyder, S. W.; Energy Systems

    2010-02-08

    Half of U.S. acetic acid production is used in manufacturing vinyl acetate monomer (VAM) and is economical only in very large production plants. Nearly 80% of the VAM is produced by methanol carbonylation, which requires high temperatures and exotic construction materials and is energy intensive. Fermentation-derived acetic acid production allows for small-scale production at low temperatures, significantly reducing the energy requirement of the process. The goal of the project is to develop a scaleable production and separation process for fermentation-derived acetic acid. Synthesis gas (syngas) will be fermented to acetic acid, and the fermentation broth will be continuously neutralized with ammonia. The acetic acid product will be recovered from the ammonium acid broth using vapor-based membrane separation technology. The process is summarized in Figure 1. The two technical challenges to success are selecting and developing (1) microbial strains that efficiently ferment syngas to acetic acid in high salt environments and (2) membranes that efficiently separate ammonia from the acetic acid/water mixture and are stable at high enough temperature to facilitate high thermal cracking of the ammonium acetate salt. Fermentation - Microbial strains were procured from a variety of public culture collections (Table 1). Strains were incubated and grown in the presence of the ammonium acetate product and the fastest growing cultures were selected and incubated at higher product concentrations. An example of the performance of a selected culture is shown in Figure 2. Separations - Several membranes were considered. Testing was performed on a new product line produced by Sulzer Chemtech (Germany). These are tubular ceramic membranes with weak acid functionality (see Figure 3). The following results were observed: (1) The membranes were relatively fragile in a laboratory setting; (2) Thermally stable {at} 130 C in hot organic acids; (3) Acetic acid rejection > 99%; and (4

  8. Development of micromachined preconcentrators and gas chromatographic separation columns by an electroless gold plating technology

    NASA Astrophysics Data System (ADS)

    Kuo, C.-Y.; Chen, P.-S.; Chen, H.-T.; Lu, C.-J.; Tian, W.-C.

    2017-03-01

    In this study, a simple process for fabricating a novel micromachined preconcentrator (μPCT) and a gas chromatographic separation column (μSC) for use in a micro gas chromatograph (μGC) using one photomask is described. By electroless gold plating, a high-surface-area gold layer was deposited on the surface of channels inside the μPCT and μSC. For this process, (3-aminopropyl) trimethoxysilane (APTMS) was used as a promoter for attaching gold nanoparticles on a silicon substrate to create a seed layer. For this purpose, a gold sodium sulfite solution was used as reagent for depositing gold to form heating structures. The microchannels of the μPCT and μSC were coated with the adsorbent and stationary phase, Tenax-TA and polydimethylsiloxane (DB-1), respectively. μPCTs were heated at temperatures greater than 280 °C under an applied electrical power of 24 W and a heating rate of 75 °C s‑1. Repeatable thermal heating responses for μPCTs were achieved; good linearity (R 2  >  0.9997) was attained at three heating rates for the temperature programme for the μSC (0.2, 0.5 and 1 °C s‑1). The volatile organic compounds (VOCs) toluene and m-xylene were concentrated over the μPCT by rapid thermal desorption (peak width of half height (PWHH)  <1.5 s) preconcentration factors for both VOCs are  >7900. The VOCs acetone, benzene, toluene, m-xylene and 1,3,5-trimethylbenzene were also separated on the μSC as evidenced by their different retention times (47–184 s).

  9. Development and validation of a high-performance liquid chromatographic method for the determination of cyproterone acetate in human skin.

    PubMed

    Henry de Hassonville, Sandrine; Chiap, Patrice; Liégeois, Jean-François; Evrard, Brigitte; Delattre, Luc; Crommen, Jacques; Piel, Géraldine; Hubert, Philippe

    2004-09-21

    In the framework of a preliminary study on the transdermal penetration of cyproterone acetate (CPA), a simple and rapid procedure involving an extraction step coupled to a HPLC-UV determination has been developed for the separation and quantification of CPA in the two main skin layers-epidermis and dermis-after local application. The separation of epidermis and dermis layers was carefully carried out by means of a sharp spatula after skin immersion in heated water at 65 degrees C. The two skin layers were then treated separately according to the same process: (1) sample homogenization by vibration after freezing with liquid nitrogen in a Mikro-Dismembrator; (2) CPA extraction with methanol after addition of the internal standard (betamethasone dipropionate); (3) centrifugation; (4) evaporation of a supernatant aliquot; (5) dissolution of the dry residue in methanol and addition of water; (6) centrifugation; (7) injection of a supernatant aliquot into the HPLC system. The separation was achieved on octadecylsilica stationary phase using a mobile phase consisting in a mixture of acetonitrile and water (40:60 (v/v)). The method was then validated using a new approach based on accuracy profiles over a CPA concentration range from 33 to 667 ng/ml for each skin layer. Finally, the method was successfully applied to the determination of CPA to several skin samples after topical application of different gel formulations containing CPA.

  10. High-performance liquid chromatographic determination of 17beta-estradiol and 17beta-estradiol-3-acetate solubilities and diffusion coefficents in silicone elastromeric intravaginal rings.

    PubMed

    Russell, J A; Malcolm, R K; Campbell, K; Woolfson, A D

    2000-07-07

    A rapid, sensitive reversed-phase high-performance liquid chromatographic method has been developed for the determination of in vitro release of 17beta-estradiol and its ester prodrug, 17beta-estradiol-3-acetate, from silicone intravaginal rings. Partial hydrolysis of the acetate under the aqueous conditions provided by the 1% benzalkonium chloride release medium necessitates its conversion to 17beta-estradiol prior to HPLC analysis. Both steroid peaks have been fully resolved from the benzalkonium chloride peaks by the reported chromatographic method, which employs a C18 bonded reversed-phase column, an acetonitrile-water (50:50, v/v) mobile phase and a UV detection wavelength of 281 nm. The peak area versus 17beta-estradiol concentration was found to be linear over the range of 0.0137-1347 microkg ml(-1). The HPLC method has also been used to determine the silicone solubilities and diffusion coefficients of the two related steroids. The almost 100-fold increase in 17beta-estradiol-3-acetate release from the silicone core-type intravaginal rings compared to 17beta-estradiol is shown to be due to a 60-fold increase in silicone solubility and a one and a half-fold increase in diffusitivity. The results demonstrate that an effective estrogen replacement therapy dose of 17beta-estradiol may be administered from a silicone intravaginal reservoir device containing the labile 17beta-estradiol-3-acetate prodrug.

  11. Effect of Coriolis force on counter-current chromatographic separation by centrifugal partition chromatography.

    PubMed

    Ikehata, Jun-Ichi; Shinomiya, Kazufusa; Kobayashi, Koji; Ohshima, Hisashi; Kitanaka, Susumu; Ito, Yoichiro

    2004-02-06

    The effect of Coriolis force on the counter-current chromatographic separation was studied using centrifugal partition chromatography (CPC) with four different two-phase solvent systems including n-hexane-acetonitrile (ACN); tert-butyl methyl ether (MtBE)-aqueous 0.1% trifluoroacetic acid (TFA) (1:1); MtBE-ACN-aqueous 0.1% TFA (2:2:3); and 12.5% (w/w) polyethylene glycol (PEG) 1000-12.5% (w/w) dibasic potassium phosphate. Each separation was performed by eluting either the upper phase in the ascending mode or the lower phase in the descending mode, each in clockwise (CW) and counterclockwise column rotation. Better partition efficiencies were attained by the CW rotation in both mobile phases in all the two-phase solvent systems examined. The mathematical analysis also revealed the Coriolis force works favorably under the CW column rotation for both mobile phases. The overall results demonstrated that the Coriolis force produces substantial effects on CPC separation in both organic-aqueous and aqueous-aqueous two-phase systems.

  12. [Optimization of two-dimensional high performance liquid chromatographic columns for highly efficient separation of intact proteins].

    PubMed

    Hong, Guangfeng; Gao, Mingxia; Yan, Guoquan; Guan, Xia; Tao, Qian; Zhang, Xiangmin

    2010-02-01

    In order to optimize two-dimensional liquid chromatographic (2D-LC) columns for highly efficient separation of proteins, several liquid chromatographic columns were investigated and evaluated. Weak anion-exchange (WAX) column was chosen as the first dimension because of its extensive protein separation power. By comparison of different WAX chromatographic columns for human liver protein separation, TSKgel DEAE-5PW column was selected as the first dimension of a 2D-LC system. For the second dimension, ten typical reversed-phase (RP) LC columns (250 mm x 4.6 mm, 5 microm, 30 nm) were investigated and evaluated. Their silica based RP stationary phases were butyl (C4), octyl (C8) or octadecyl (C18). To evaluate the retention behavior and non-specific protein adsorption ability of these ten columns, four neutral compounds (uracil, nitrobenzene, naphthalene and fluorene) and three standard proteins (cytochrome C, myoglobin and albumin from chicken egg white) were adopted and separated by RPLC. Meantime, WAX fractions were used to investigate the separation ability of different alkyl-bonded silica stationary phase columns for complex protein samples. By comparison of column separation efficiency, adsorption of intact proteins and sample analysis, Jupiter 300 C4 column was finally employed for its excellent separation ability. Optimization of WAX and RPLC columns offers reliable foundation for the construction of 2D-LC protein separation systems.

  13. Comprehensive two-dimensional gas chromatographic separations with a microfabricated thermal modulator.

    PubMed

    Serrano, Gustavo; Paul, Dibyadeep; Kim, Sung-Jin; Kurabayashi, Katsuo; Zellers, Edward T

    2012-08-21

    Rapid, comprehensive two-dimensional gas chromatographic (GC × GC) separations by use of a microfabricated midpoint thermal modulator (μTM) are demonstrated, and the effects of various μTM design and operating parameters on performance are characterized. The two-stage μTM chip consists of two interconnected spiral etched-Si microchannels (4.2 and 2.8 cm long) with a cross section of 250 × 140 μm(2), an anodically bonded Pyrex cap, and a cross-linked wall coating of poly(dimethylsiloxane) (PDMS). Integrated heaters provide rapid, sequential heating of each μTM stage, while a proximate, underlying thermoelectric cooler provides continual cooling. The first-dimension column used for GC × GC separations was a 6 m long, 250 μm i.d. capillary with a PDMS stationary phase, and the second-dimension column was a 0.5 m long, 100 μm i.d. capillary with a poly(ethylene glycol) phase. Using sets of five to seven volatile test compounds (boiling point ≤174 °C), the effects of the minimum (T(min)) and maximum (T(max)) modulation temperature, stage heating lag/offset (O(s)), modulation period (P(M)), and volumetric flow rate (F) on the quality of the separations were evaluated with respect to several performance metrics. Best results were obtained with a T(min) = -20 °C, T(max) = 210 °C, O(s) = 600 ms, P(M) = 6 s, and F = 0.9 mL/min. Replicate modulated peak areas and retention times were reproducible to <5%. A structured nine-component GC × GC chromatogram was produced, and a 21 component separation was achieved in <3 min. The potential for creating portable μGC × μGC systems is discussed.

  14. Anion exchange chromatographic separation of inositol phosphates and their quantification by gas chromatography.

    PubMed

    Heathers, G P; Juehne, T; Rubin, L J; Corr, P B; Evers, A S

    1989-01-01

    The direct measurement of mass of inositol trisphosphate from biologic samples is described. Separation of inositol monophosphate, bisphosphate, trisphosphate, and inositol tetrakisphosphate was achieved using anion exchange chromatography with a sodium sulfate gradient. In addition, separation of the isomers of each inositol phosphate was performed using HPLC procedures. The individual inositol phosphate fractions were subsequently dephosphorylated and desalted. The myo-inositol from each fraction was then derivatized to the hexatrimethylsilyl derivative and the myo-inositol derivatives were quantified by a novel gas chromatographic analysis using the hexatrimethylsilyl derivative of chiro-inositol as an internal concentration reference. This method is a reproducible and relatively rapid procedure for the direct quantification of inositol phosphate mass which overcomes many of the problems associated with the use of radiolabeled precursors. The method is a significant improvement over existing procedures for the quantitative determination of the mass of inositol phosphate by virtue of improved recovery, sensitivity, and technical simplicity. The applicability of this method is illustrated by the quantitative determination of inositol trisphosphate in response to norepinephrine stimulation of adult canine myocytes and cerebral cortical brain slices and by measurement of the isomers of inositol trisphosphate in isolated myocytes.

  15. A novel and effective chromatographic approach to the separation of isoflavone derivatives from Pueraria lobata.

    PubMed

    Fu, Jiang; Jing, Wenguang; Wang, Weihao; Chen, Sha; Zhang, Jun; Liu, An

    2015-03-05

    A novel and effective chromatographic approach to the separation and purification of isoflavone compounds from Pueraria lobata is described. The method is based on flash chromatography (FC), coupled to preparative high performance liquid chromatography (prep-HPLC) via a six-way valve. The FC step comprised tandem reversed phase columns, pre-packed with MCI gel (Mitsubishi Chemical Corp., Tokyo, Japan) and C18 (Fuji Silysia Chemical Ltd, Osaka, Japan) resin, respectively, and was designed to separate a crude Pueraria lobata extract into several preliminary fractions. Fractions containing the target compounds were then directly injected via the six-way valve into prep-HPLC columns, without further treatment, for final isolation and purification. Nine isoflavonoids were successfully isolated, three through an online mode and the other six through an offline mode. The purities of all compounds exceeded 95.0%, as determined by HPLC with an UV-vis photodiode array detector. The convenience, low solvent consumption, and time-saving advantages of this method offer an attractive and promising approach to the isolation of natural products.

  16. Facile room-temperature solution-phase synthesis of a spherical covalent organic framework for high-resolution chromatographic separation.

    PubMed

    Yang, Cheng-Xiong; Liu, Chang; Cao, Yi-Meng; Yan, Xiu-Ping

    2015-08-07

    A simple and facile room-temperature solution-phase synthesis was developed to fabricate a spherical covalent organic framework with large surface area, good solvent stability and high thermostability for high-resolution chromatographic separation of diverse important industrial analytes including alkanes, cyclohexane and benzene, α-pinene and β-pinene, and alcohols with high column efficiency and good precision.

  17. Development and validation of a reversed-phase liquid chromatographic method for analysis of estradiol valerate and medroxyprogesterone acetate in a tablet formulation.

    PubMed

    Segall, A; Hormaechea, F; Vitale, M; Perez, V; Pizzorno, M T

    1999-04-01

    A simple and accurate liquid chromatographic method was developed for estimation of estradiol valerate and medroxyprogesterone acetate in pharmaceuticals. Drugs were chromatographed on a reverse phase C18 column, using a mixture (30:70) of ammonium nitrate buffer and acetonitrile and eluants monitored at a wavelength of 280 nm. Solution concentrations were measured on a weight basis to avoid the use of an internal standard. The method was statistically validated for its linearity, accuracy, precision and selectivity. Due to its simplicity and accuracy, the authors believe that the method may be used for routine quality control analysis. It does not require any specific sample preparation except the use of a column guard before the analytical column and suitable prefilter attached to the syringe prior to injection.

  18. Liquid-chromatographic separation and on-line bioluminescence detection of creatine kinase isoenzymes

    SciTech Connect

    Bostick, W.D.; Denton, M.S.; Dinsmore, S.R.

    1980-01-01

    Isoenzymes of creatine kinase were separated by anion-exchange chromatography, with use of an elution gradient containing lithium acetate (0.1 to 0.6 mol/L). A stream splitter was used to divert a 5% side stream of column effluent, which was subsequently mixed with the reagents necessary for bioluminescence assay of the separated isoenzymes. The use of the stream splitter greatly decreased the rate of consumption of reagent and, when combined with a peristaltic pumping system, permitted independent control of the side-stream flow rate. Thus both the residence interval in a delay coil in which the ATP reaction product is formed and the bioluminescence emission was monitored in a flow-through fluorometer without use of an external light source or filters. Separation and detection of the isoenzymes of creatine kinase were rapid, sensitive, and highly selective. The incremental decrease of bioluminescence response owing to inhibition by the ions in the eluent was less than 31% across the entire gradient.

  19. Ion Exchange and Thin Layer Chromatographic Separation and Identification of Amino Acids in a Mixture: An Experiment for General Chemistry and Biotechnology Laboratories

    ERIC Educational Resources Information Center

    Brunauer, Linda S.; Caslavka, Katelyn E.; Van Groningen, Karinne

    2014-01-01

    A multiday laboratory exercise is described that is suitable for first-year undergraduate chemistry, biochemistry, or biotechnology students. Students gain experience in performing chromatographic separations of biomolecules, in both a column and thin layer chromatography (TLC) format. Students chromatographically separate amino acids (AA) in an…

  20. Using precipitation by polyamines as an alternative to chromatographic separation in antibody purification processes.

    PubMed

    Ma, Junfen; Hoang, Hai; Myint, Thomas; Peram, Thanmaya; Fahrner, Robert; Chou, Judy H

    2010-03-15

    Polyamine precipitation conditions for removing host cell protein impurities from the cell culture fluid containing monoclonal antibody were studied. We examined the impact of polyamine concentration, size, structure, cell culture fluid pH and ionic strength. A 96-well microtiter plate based high throughput screening method was developed and used for evaluating different polyamines. Polyallylamine, polyvinylamine, branched polyethyleneimine and poly(dimethylamine-co-epichlorohydrin-ethylenediamine) were identified as efficient precipitants in removing host cell protein impurities. Leveraging from the screening results, we incorporated a polyamine precipitation step into a monoclonal antibody purification process to replace the Protein A chromatography step. The optimization of the overall purification process was performed by taking the mechanisms of both precipitation and chromatographic separation into account. The precipitation-containing process removed a similar amount of process-related impurities, including host cell proteins, DNA, insulin and gentamicin and maintained similar product quality in respect of size and charge variants to chromatography based purification. Overall recovery yield was comparable to the typical Protein A affinity chromatography based antibody purification process.

  1. Surface-modified polystyrene beads as photografting imprinted polymer matrix for chromatographic separation of proteins.

    PubMed

    Qin, Lei; He, Xi-Wen; Zhang, Wei; Li, Wen-You; Zhang, Yu-Kui

    2009-01-30

    A new and facile fabricating method for lysozyme molecularly imprinted polymer beads (lysozyme-MIP beads) in aqueous media was presented. Mesoporous chloromethylated polystyrene beads (MCP beads) containing dithiocarbamate iniferter (initiator transfer agent terminator) were used as supports for the grafting of lysozyme imprinted copolymers with acrylamide and N,N'-methylenebisacrylamide through surface initiated living-radical polymerization (SIP). After the polymerization, a layer of lysozyme-MIP was formed on the MCP beads. The SIP allowed an efficient control of the grafting process and suppressed solution propagation. Therefore, the obtained lysozyme-MIP beads had a large quantity of well-distributed pores on the surface without any visible gel formation in solution and were more advantageous comparing with traditional MIPs which were prepared by traditionally initiated radical polymerization. The obtained composites were characterized by Fourier transform infrared spectroscopy, elemental analysis, nitrogen sorption analysis and scanning electron microscopy. Chromatographic behaviors of the column packed with lysozyme-MIP beads exhibited ability in separating lysozyme from competitive protein (bovine hemoglobin, bovine serum albumin, ovalbumin or cytochrome c) in aqueous mobile phase.

  2. Optimisation of temperature-programmed gas chromatographic separation of organochloride pesticides by response surface methodology.

    PubMed

    D'Archivio, Angelo Antonio; Maggi, Maria Anna; Marinelli, Cristina; Ruggieri, Fabrizio; Stecca, Fabrizio

    2015-12-04

    A response surface methodology (RSM) approach is applied to optimise the temperature-programme gas-chromatographic separation of 16 organochloride pesticides, including 12 compounds identified as highly toxic chemicals by the Stockholm Convention on Persistent Organic Pollutants. A three-parameter relationship describing both linear and curve temperature programmes is derived adapting a model previously used in literature to describe concentration gradients in liquid chromatography with binary eluents. To investigate the influence of the three temperature profile descriptors (the starting temperature, the gradient duration and a shape parameter), a three-level full-factorial design of experiments is used to identify suitable combinations of the above variables spanning over a useful domain. Resolutions of adjacent peaks are the responses modelled by RSM using two alternative methods: a multi-layer artificial network (ANN) and usual polynomial regression. The proposed ANN-based approach permits to model simultaneously the resolutions of all the consecutive analyte pairs as a function of the temperature profile descriptors. Four critical pairs giving partially overlapped peaks are identified and multiresponse optimisation is carried out by analysing the surface plot of a global resolution defined as the average of the resolutions of the critical pairs. Descriptive/predictive performance and applicability of the ANN and polynomial RSM methods are compared and discussed.

  3. CHARACTERISTICS OF POROUS CELLULOSE ACETATE MEMBRANES FOR THE SEPARATION OF SOME INORGANIC SALTS IN AQUEOUS SOLUTION,

    DTIC Science & Technology

    Experimental results are presented to illustrate the effect of operating variables on the separation and flow characteristics of porous cellulose ... acetate membranes. The results are discussed from the point of view of the preferential sorption and capillary flow mechanism, together with the concept

  4. Development and assessment of a miniaturised centrifugal chromatograph for reversed-phase separations in micro-channels.

    PubMed

    Penrose, Andrew; Myers, Peter; Bartle, Keith; McCrossen, Sean

    2004-08-01

    This paper describes the micro-fabrication and preliminary assessment of a miniature polydimethylsiloxane (PDMS) device for performing rapid, parallel liquid phase chromatographic separations driven by centrifugal force in microchannels. Device components include a main separating channel, into which a high performance liquid chromatography (HPLC) particulate stationary phase was packed under pressure by application of centrifugal force, in addition to solvent and sample reservoirs. Also described are methods for sealing such devices based upon partial polymerisation of PDMS. The mobile phase flow rate through a typical device was measured and several important chromatographic parameters determined from a test separation. An expression describing mobile phase flow through packed channels was also developed, based upon work on liquid flow in open micro-channels. Good agreement between predicted and measured flow rates were observed. Some predictions for potential uses of such devices and possibilities for further miniaturisation are discussed.

  5. Separation and identification of various vulcanization agents and antioxidants in two types of rubber by chromatographic and spectrometric methods.

    PubMed

    Chauveau, S; Hamon, M; Leleu, E

    1991-11-01

    The aim of this study was to separate and identify by chromatographic and spectrometric methods, the various allergenic vulcanization agents and antioxidants used in the manufacture of industrial rubber. Specimens of elastomers were manufactured specially for this study. The specificity of the gas chromatographic method developed allows separation of all the manufacturing additives in the selected rubber types after one injection only, even though they belong to extremely varied chemical categories. The GLC method was coupled with mass spectrometry, which permitted identification of the peaks obtained and the study of the fragmentation of the 4 reference products under various conditions. Separation by TLC was performed in parallel on the same extracts, allowing rapid identification of the products tested for, and showed new spots after vulcanization.

  6. Stable hydrogen isotopic analysis of nanomolar molecular hydrogen by automatic multi-step gas chromatographic separation.

    PubMed

    Komatsu, Daisuke D; Tsunogai, Urumu; Kamimura, Kanae; Konno, Uta; Ishimura, Toyoho; Nakagawa, Fumiko

    2011-11-15

    We have developed a new automated analytical system that employs a continuous flow isotope ratio mass spectrometer to determine the stable hydrogen isotopic composition (δD) of nanomolar quantities of molecular hydrogen (H(2)) in an air sample. This method improves previous methods to attain simpler and lower-cost analyses, especially by avoiding the use of expensive or special devices, such as a Toepler pump, a cryogenic refrigerator, and a special evacuation system to keep the temperature of a coolant under reduced pressure. Instead, the system allows H(2) purification from the air matrix via automatic multi-step gas chromatographic separation using the coolants of both liquid nitrogen (77 K) and liquid nitrogen + ethanol (158 K) under 1 atm pressure. The analytical precision of the δD determination using the developed method was better than 4‰ for >5 nmol injections (250 mL STP for 500 ppbv air sample) and better than 15‰ for 1 nmol injections, regardless of the δD value, within 1 h for one sample analysis. Using the developed system, the δD values of H(2) can be quantified for atmospheric samples as well as samples of representative sources and sinks including those containing small quantities of H(2) , such as H(2) in soil pores or aqueous environments, for which there is currently little δD data available. As an example of such trace H(2) analyses, we report here the isotope fractionations during H(2) uptake by soils in a static chamber. The δD values of H(2) in these H(2)-depleted environments can be useful in constraining the budgets of atmospheric H(2) by applying an isotope mass balance model.

  7. Experimental Confirmation of Isotope Fractionation in Thiomolybdates Using Ion Chromatographic Separation and Detection by Multicollector ICPMS.

    PubMed

    Kerl, Carolin F; Lohmayer, Regina; Bura-Nakić, Elvira; Vance, Derek; Planer-Friedrich, Britta

    2017-03-07

    Molybdenum (98)Mo/(95)Mo isotope ratios are a sediment paleo proxy for the redox state of the ancient ocean. Under sulfidic conditions, no fractionation between seawater and sediment should be observed if molybdate (MoO4(2-)) is quantitatively transformed to tetrathiomolybdate (MoS4(2-)) and precipitated. However, quantum mechanical calculations previously suggested that incomplete sulfidation could be associated with substantial fractionation. To experimentally confirm isotope fractionation in thiomolybdates, a new approach for determination of isotope ratios of individual thiomolybdate species was developed that uses chromatography (HPLC-UV) to separate individual thiomolybdates, collecting each peak and analyzing isotope ratios with multicollector inductively coupled plasma mass spectrometry (MC-ICPMS). Using commercially available MoO4(2-) and MoS4(2-) standards, the method was evaluated and excellent reproducibility and accuracy were obtained. For species with longer retention times, complete chromatographic peaks had to be collected to avoid isotope fractionation within peaks. Isotope fractionation during formation of thiomolybdates could be experimentally proven for the first time in the reaction of MoO4(2-) with 20-fold or 50-fold excess of sulfide. The previously calculated isotope fractionation for MoS4(2-) was confirmed, and the result for MoO2S2(2-) was in the predicted range. Isotopic fractionation during MoS4(2-) transformation with pressurized air was dominated by kinetic fractionation. Further optimization and online-coupling of the HPLC-MC-ICPMS approach for determination of low concentrations in natural samples will greatly help to obtain more accurate species-selective isotope information.

  8. High-performance reversed-phase ion-pair chromatographic study of myo-inositol phosphates. Separation of myo-inositol phosphates, some common nucleotides and sugar phosphates.

    PubMed

    Patthy, M; Balla, T; Arányi, P

    1990-12-07

    A detailed study of all the major chromatographic variables affecting the retention behaviour and separation of myo-inositol phosphates in reversed-phase ion-pair chromatographic systems was carried out. The parameters studied included the eluent concentration of the pairing ion, the eluent concentration of the organic modifier and the buffer salt, the pH of the eluent, the minimum column plate count necessary for the separation of the inositol trisphosphate isomers and isocratic and gradient modes of separation. The retention behaviour of some common nucleotides and sugar phosphates was also investigated as these phosphates present chromatographic interference problems in biochemical studies based on the cellular incorporation of [32P]Pi. The separation methods developed appear to be superior to established anion-exchange separation techniques in terms of separation speed and "mildness" of the chromatographic conditions.

  9. A theoretical model for the separation of glucose and fructose mixtures by using a semicontinuous chromatographic refiner

    SciTech Connect

    Lee, Kwang Nam; Lee, Won Kook )

    1992-03-01

    The separation of a glucose and fructose mixture was experimentally performed by using a semicontinuous chromatographic refiner (SCCR) packed with Ca{sup 2+} ion in the form of DOWEX 50W 12X resin. The plug flow model with velocity-dependent mass transfer resistance was resistance was presented for calculating both products and on-concentrations in the SCCR unit, and the validity of the model was experimentally confirmed.

  10. Improvement in HPLC separation of acetic acid and levulinic acid in the profiling of biomass hydrolysate.

    PubMed

    Xie, Rui; Tu, Maobing; Wu, Yonnie; Adhikari, Sushil

    2011-04-01

    5-Hydroxymethylfurfural (HMF) and furfural could be separated by the Aminex HPX-87H column chromatography, however, the separation and quantification of acetic acid and levulinic acid in biomass hydrolysate have been difficult with this method. In present study, the HPLC separation of acetic acid and levulinic acid on Aminex HPX-87H column has been investigated by varying column temperature, flow rate, and sulfuric acid content in the mobile phase. The column temperature was found critical in resolving acetic acid and levulinic acid. The resolution for two acids increased dramatically from 0.42 to 1.86 when the column temperature was lowered from 60 to 30 °C. So did the capacity factors for levulinic acid that was increased from 1.20 to 1.44 as the column temperature dropped. The optimum column temperature for the separation was found at 45 °C. Variation in flow rate and sulfuric acid concentration improved not as much as the column temperature did.

  11. Multidimensional chromatographic techniques for hydrophilic copolymers II. Analysis of poly(ethylene glycol)-poly(vinyl acetate) graft copolymers.

    PubMed

    Knecht, Daniela; Rittig, Frank; Lange, Ronald F M; Pasch, Harald

    2006-10-13

    A large variety of hydrophilic copolymers is applied in different fields of chemical industry including bio, pharma and pharmaceutical applications. For example, poly(ethylene glycol)-poly(vinyl alcohol) graft copolymers that are used as tablet coatings are responsible for the controlled release of the active compounds. These copolymers are produced by grafting of vinyl acetate onto polyethylene glycol (PEG) and subsequent hydrolysis of the poly(ethylene glycol)-poly(vinyl acetate) graft copolymers. The poly(ethylene glycol)-poly(vinyl acetate) copolymers are distributed with regard to molar mass and chemical composition. In addition, they frequently contain the homopolymers polyethylene glycol and polyvinyl acetate. The comprehensive analysis of such complex systems requires hyphenated analytical techniques, including two-dimensional liquid chromatography and combined LC and nuclear magnetic resonance spectroscopy. The development and application of these techniques are discussed in the present paper.

  12. [Contamination mechanism and regeneration strategies of chromatographic resin in separation process for expression product from mammary gland bioreactor].

    PubMed

    Sun, Xiyan; Zhang, Yan; Li, Yan; Luo, Jian; Qin, Peiyong; Su, Zhiguo

    2011-11-01

    This study focused on the contamination mechanism and regeneration strategies of sulfopropyl ion exchange resin (SP Sepharose FF) during the separation of recombinant human lactoferrin from transgenic bovine milk. We analyzed primary constituents' contents in chromatorgraphic material and fractions. The results showed that the lipid in milk can clog the column or adhere to the resin through hydrophobic interaction, leading to an increase in column pressure. Some casein molecules were found to adsorb onto the resin through electrostatic interaction, therefore the adsorption capacity was decreased. There was no direct interaction between lactose and the resin in the chromatorgraphic process. Increased continuous chromatographic cycles and prolonged time interval between protein purification and column regeneration could enhance the undesirable interaction between the contaminants and resin, thus lowering the regeneration efficiency. NaOH was found to be effective in the removal of lipid and casein molecules from the column. Furthermore, normal microstructure and chromatographic performance of the ion exchanger was recovered after this cleaning procedure.

  13. Electrospun cellulose acetate membrane for size separating and antibacterial screening of crude polysaccharides.

    PubMed

    Chumpol, Jiraporn; Siri, Sineenat

    2016-12-01

    This study aims to produce electrospun cellulose acetate (CA) membrane as the alternative supporting medium for a separation of crude polysaccharides by electrophoresis and a screening of their antibacterial activity. Among the tested conditions of fabrication, electrospun CA membrane at 57% porosity showed the best separation of each polysaccharide from the standard mixture and the crude extract of Aloe vera via electrophoresis. As compared with the commercial CA membrane, the produced electrospun CA membrane demonstrated more separated spots of polysaccharides. The antibacterial activity of the electrophoretic polysaccharide was also determined against Escherichia coli and Staphylococcus aureus as the inhibition zone after the bacterial culture agar was overlaid on the membrane and incubated for 24 h. The results of this study suggested the potential application of electrospun CA membrane combining with electrophoresis as a simple method for separating crude polysaccharides and screening for their antibacterial activity.

  14. Thin-layer chromatographic specification and separation of Cu(1+), Cu(2+), Ni(2+), and Co(2+) cations.

    PubMed

    Savasci, Sahin; Akçay, Mehmet; Ergül, Soner

    2010-07-01

    The M(PyDTC)(2) (M: Cu, Co, or Ni) and CuPyDTC complexes, prepared by reactions of ammonium pyrrolidinedithiocarbamate with metal nitrates, are examined for qualitative analysis, speciation, and mutual separation using thin-layer chromatography systems. These complexes and their mixtures are spotted to the activated and non-activated thin layers of silica gel 60GF(254) (Si-60GF(254)) with a 250-microm thickness. Toluene-dichloromethane mixtures (4:1, 1:1, 1:4 v/v) are used as mobile phases for running of the complexes. All of these chromatographic systems are successfully used for speciation of Cu(2+) and Cu(1+) cations. The best analytical separation for the qualitative analysis of corresponding metal cations and mutual separation of components in M(PyDTC)(2) and CuPyDTC complexes are obtained when using pure toluene-dichloromethane (1:1 v/v) on the activated layer. This study shows that it is possible to qualitatively analyze and satisfactorily separate a mixture of Cu(1+), Cu(2+), Ni(2+), and Co(2+) cations on cited chromatographic systems. These results may be also said for the adaptability or validity on column chromatography.

  15. Chromatographic separation of platinum group metals from simulated high level liquid waste using macroporous silica-based adsorbents.

    PubMed

    Xu, Yuanlai; Kim, Seong-Yun; Ito, Tatsuya; Tokuda, Haruki; Hitomi, Keitaro; Ishii, Keizo

    2013-10-18

    To separate platinum group metals (PGMs) from high level liquid waste, three novel macroporous silica-based adsorbents, namely, (Crea+Dodec)/SiO2-P, (Crea+TOA)/SiO2-P and (MOTDGA+TOA)/SiO2-P, were synthesized by introducing extractants Crea (N',N'-di-n-hexyl-thiodiglycolamide), TOA (Tri-n-octylamine), MOTDGA (N,N'-dimethyl-N,N'-di-n-octyl-thiodiglycolamide) along with theirs modifier, Dodec (n-dodecyl alcohol), into 50μm diameter SiO2-P particles by impregnation. Chromatographic separation of PGMs from simulated high level liquid waste was investigated by column method. It was found that 100% of Pd(II) and Re(VII) could be eluted out from simulate HLLW in 3.0M HNO3 solution using three adsorbents. For Ru(III) and Rh(III), high temperature has distinct effect on the adsorption rate and a further study for Ru(III) and Rh(III) is necessary to separate them from HLLW completely. In all six column experiments, a relatively satisfactory chromatographic separation operating for PGMs from simulated HLLW was obtained using (Crea+TOA)/SiO2-P adsorbent packed column at 323K.

  16. Kinetic optimisation of the reversed phase liquid chromatographic separation of rooibos tea (Aspalathus linearis) phenolics on conventional high performance liquid chromatographic instrumentation.

    PubMed

    Beelders, Theresa; Sigge, Gunnar O; Joubert, Elizabeth; de Beer, Dalene; de Villiers, André

    2012-01-06

    Rooibos tea, produced from the endemic South African shrub Aspalathus linearis, has various health-promoting benefits which are attributed to its phenolic composition. Generating reliable, quantitative data on these phenolic constituents is the first step towards documenting the protective effects associated with rooibos tea consumption. Reversed phase liquid chromatographic (RP-LC) methods currently employed in the quantitative analysis of rooibos are, however, hampered by limited resolution and/or excessive analysis times. In order to overcome these limitations, a systematic approach towards optimising the RP-LC separation of the 15 principal rooibos tea phenolics on a 1.8 μm phase using conventional HPLC instrumentation was adopted. Kinetic plots were used to obtain the optimal configuration for the separation of the target analytes within reasonable analysis times. Simultaneous optimisation of temperature and gradient conditions provided complete separation of these rooibos phenolics on a 1.8 μm C18 phase within 37 min. The optimised HPLC-DAD method was validated and successfully applied in the quantitative analysis of aqueous infusions of unfermented and fermented rooibos. Major phenolic constituents of fermented rooibos were found to be a phenylpropanoid phenylpyruvic acid glucoside (PPAG), the dihydrochalcone C-glycoside aspalathin, the flavones isoorientin and orientin, and a flavonol O-diglycoside tentatively identified as quercetin-3-O-robinobioside. Content values for PPAG, ferulic acid and quercetin-3-O-robinobioside in rooibos are reported here for the first time. Mass spectrometric (MS) and tandem MS detection were used to tentatively identify 13 additional phenolic compounds in rooibos infusions, including a new luteolin-6-C-pentoside-8-C-hexoside and a novel C-8-hexosyl derivative of aspalathin reported here for the first time.

  17. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    PubMed

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods.

  18. Cyclotriveratrylene as a new-type stationary phase for gas chromatographic separations of halogenated compounds and isomers.

    PubMed

    Lv, Qing; Zhang, Qing; Qi, Meiling; Bai, Hua; Ma, Qiang; Meng, Xianshuang; Fu, Ruonong

    2015-07-24

    Cyclotriveratrylene (CTV) is reported here for the first time as stationary phase for capillary gas chromatographic (GC) separations. CTV stationary phase showed weak polarity comparable to the conventional 5% phenyl polysiloxane stationary phase but exhibited different retention behaviours and higher resolution for some of the indicated analytes. Most importantly, CTV stationary phase exhibited preferential selectivity for halogenated compounds, positional and geometrical isomers. Effect of column temperature on retention and thermal stability of CTV column were also investigated. Moreover, CTV capillary column showed good repeatability in terms of run-to-run, day-to-day and column-to-column. The unique physicochemical features and efficient separation ability for analytes of close properties show the potential of CTV as a new-type stationary phase in GC as well as separation science.

  19. How to compare separation selectivity of high-performance liquid chromatographic columns properly?

    PubMed

    Andrić, Filip; Héberger, Károly

    2017-03-10

    Comparison and selection of chromatographic columns is an important part of development as well as validation of analytical methods. Presently there is abundant number of methods for selection of the most similar and orthogonal columns, based on the application of limited number of test compounds as well as quantitative structure retention relationship models (QSRR), from among Snyder's hydrophobic-subtraction model (HSM) have been most extensively used. Chromatographic data of 67 compounds were evaluated using principal component analysis (PCA), hierarchical cluster analysis (HCA), non-parametric ranking methods as sum of ranking differences (SRD) and generalized pairwise correlation method (GPCM), both applied as a consensus driven comparison, and complemented by the comparison with one variable at a time (COVAT) approach. The aim was to compare the ability of the HSM approach and the approach based on primary retention data of test solutes (logk values) to differentiate among ten highly similar C18 columns. The ranking (clustering) pattern of chromatographic columns based on primary retention data and HSM parameters gave different results in all instances. Patterns based on retention coefficients were in accordance with expectations based on columns' physicochemical parameters, while HSM parameters provided a different clustering. Similarity indices calculated from the following dissimilarity measures: SRD, GPCM Fisher's conditional exact probability weighted (CEPW) scores; Euclidian, Manhattan, Chebyshev, and cosine distances; Pearson's, Spearman's, and Kendall's, correlation coefficients have been ranked by the consensus based SRD. Analysis of variance confirmed that the HSM model produced statistically significant increases of SRD values for the majority of similarity indices, i.e. HS transformation of original retention data yields significant loss of information, and finally results in lower performance of HSM methodology. The best similarity measures were

  20. Comparison of nano and conventional liquid chromatographic methods for the separation of (+)-catechin-ethyl-malvidin-3-glucoside diastereoisomers.

    PubMed

    Kučera, Lukáš; Fanali, Salvatore; Aturki, Zeineb; Pospíšil, Tomáš; Bednář, Petr

    2016-01-08

    Nano-liquid chromatography and conventional HPLC were used for the separation of diastereomers of (+)-catechin-ethyl-malvidin-3-glucoside. Those bridged anthocyanin dyes were obtained by reaction of (+)-catechin with malvidin-3-glucoside in the presence of acetaldehyde. Both diastereomers were isolated with semipreparative chromatography and their structures were confirmed by nuclear magnetic resonance and mass spectrometry. In-laboratory prepared capillary columns packed with fully porous particles Chromosphere C18, dp=3μm, core-shell particles Kinetex C18, dp=2.6μm (100μm i.d.) and monolithic column Chromolith CapRod (100μm i.d.) were used for the separation of (+)-catechin, malvidin-3-glucoside and both diastereomers. Chromosphere C18 stationary phase provided the best chromatographic performance. Mobile phase containing water:acetonitrile (80:20) acidified with trifluoroacetic acid (0.1%, v/v/v) was used in an isocratic elution mode with a flow rate of 360nLmin(-1). Separation of studied compounds was achieved in less than 7min under optimized conditions. The nano-liquid chromatographic method and a conventional HPLC one using the same fully porous particles (Chromosphere C18, 3μm, 100mm×4.6mm) were compared providing higher separation efficiency with the first analytical method and similar selectivity. A better peak symmetry and higher resolution of the studied diastereomers was achieved by conventional chromatography. Nevertheless, nano-liquid chromatography appeared to be useful for the separation of complex anthocyanin dyes and can be utilized for their analysis in plant and food micro-samples. The developed method was used for analysis of red wine grape pomace.

  1. Post-synthetic modification of MIL-101(Cr) with pyridine for high-performance liquid chromatographic separation of tocopherols.

    PubMed

    Yang, Fang; Yang, Cheng-Xiong; Yan, Xiu-Ping

    2015-05-01

    Effective separation of tocopherols is challenging and significant due to their structural similarity and important biological role. Here we report the post-synthetic modification of metal-organic framework (MOF) MIL-101(Cr) with pyridine for high-performance liquid chromatographic (HPLC) separation of tocopherols. Baseline separation of four tocopherols was achieved on a pyridine-grafted MIL-101(Cr) packed column within 10 min using hexane/isopropanol (96:4, v/v) as the mobile phase at a flow rate of 0.5 mL min(-1). The pyridine-grafted MIL-101(Cr) packed column gave high column efficiency (85,000 plates m(-1) for δ-tocopherol) and good precision (0.2-0.3% for retention time, 1.8-3.4% for peak area, 2.6-2.7% for peak height), and also offered much better performance than unmodified MIL-101(Cr) and commercial amino-bonded silica packed column for HPLC separation of tocopherols. The results not only show the promising application of pyridine-grafted MIL-101(Cr) as a novel stationary phase for HPLC separation of tocopherols, but also reveal a facile post-modification of MOFs to expand the application of MOFs in separation sciences.

  2. Countercurrent Chromatographic Separation of Proteins Using an Eccentric Coiled Column with Synchronous and Nonsynchronous Type-J Planetary Motions

    PubMed Central

    SHINOMIYA, Kazufusa; YOSHIDA, Kazunori; TOKURA, Koji; TSUKIDATE, Etsuhiro; YANAGIDAIRA, Kazuhiro; ITO, Yoichiro

    2015-01-01

    Protein separation was performed using the high-speed counter-current chromatograph (HSCCC) at both synchronous and nonsynchronous type-J planetary motions. The partition efficiency was evaluated with two different column configurations, eccentric coil and toroidal coil, on the separation of a set of stable protein samples including cytochrome C, myoglobin and lysozyme with a polymer phase system composed of 12.5% (w/w) polyethylene glycol 1000 and 12.5% (w/w) dibasic potassium phosphate. Better peak resolution was obtained by the eccentric coil than by the toroidal coil using either lower or upper phase as the mobile phase. The peak resolution was further improved using the eccentric coil by the nonsynchronous type-J planetary motion with the combination of 1066 rpm of column rotation and 1000 rpm of revolution. PMID:25765276

  3. Liquid chromatographic enantiomer separation of 1-naphthylamides of chiral acids using several amylose- and cellulose-derived chiral stationary phases.

    PubMed

    Islam, Md F; Adhikari, Suraj; Paik, Man-Jeong; Lee, Wonjae

    2017-03-01

    The liquid chromatographic enantiomer separation of various chiral acids as 1-naphthylamides was performed using several chiral stationary phases (CSPs). The CSPs used in this study were six covalently bonded and four coated type CSPs derived from amylose and cellulose derivatives as chiral selectors. The degree of enantioseparation is affected by the structure of chiral acids and the CSPs used, which have different chiral selectors and types of immobilization. For the enantiomer resolution of chiral acids as 1-naphthylamide derivatives, the performance of the coated type Lux Cellulose-1 was superior to those of the other CSPs, except for 2-aryloxypropionic acid derivatives. Owing to the strong ultraviolet absorbance of the 1-naphthyl group, the convenient analytical method developed and validated in this study could be expected to be very useful for the enantiomer separation of various chiral acids as 1-naphthylamide derivatives using polysaccharide-derived CSPs.

  4. Gas chromatographic separation of diastereomeric isoprenoids as molecular markers of oil pollution.

    PubMed

    Berthou, F; Friovourt, M P

    1981-12-18

    By means of high-performance glass capillary gas chromatography (GC), diastereomeric isoprenoids were resolved into double peaks. The retention indices on three liquid phases and the mass spectra of the diastereoisomers were almost similar. The leading GC peaks represent the isoprenoids of fossil origin, while the rear peaks correspond to those of recent origin. Computerized gas chromatography-mass spectrometry was used for fingerprinting isoprenoids in different samples. The mass fragmentation patterns were characteristic of the branched alkanes. Hydrocarbon mixtures from four crude oil spills in the sea and from polluted and oil-free oyster tissues were investigated. The relative ratios of n-alkanes/pristane or phytane were shown to be strongly dependent on the chromatographic resolution of the isoprenoid peaks. It is suggested that the double GC peaks in the isoprenoid series are an unmistakable sign of oil pollution.

  5. Column chromatographic separation of Hg(II), La(III), Ce(III), and In(III) from other metal ions in NH/sub 4/Cl-CH/sub 3/COOH medium by cation exchange

    SciTech Connect

    Srivastava, U.; Mahan, A.; Ghose, A.K.; Dey, A.K.

    1980-01-01

    Cation exchange equilibrium distribution coefficients (K) with the (Dowex 50W-X8) H/sup +/ form have been determined for 21 metal ions in media consisting of mixtures of 0.7 mol/dm/sup 3/ acetic acid and varying concentrations (0.16, 0.32, 0.48, 0.64, 0.96, and 1.28 mol/dm/sup 3/) of ammonium chloride. The distribution coefficients were determined by the batch technique for finding the conditions for the mentioned separations. The column chromatographic separations achieved were all quantitative. The results of the resolution of the synthetic binary and ternary mixtures along with the elution curves are presented. 3 figures, 4 tables.

  6. Superhydrophobic, Hybrid, Electrospun Cellulose Acetate Nanofibrous Mats for Oil/Water Separation by Tailored Surface Modification.

    PubMed

    Arslan, Osman; Aytac, Zeynep; Uyar, Tamer

    2016-08-03

    Electrospun cellulose acetate nanofibers (CA-NF) have been modified with perfluoro alkoxysilanes (FS/CA-NF) for tailoring their chemical and physical features aiming oil-water separation purposes. Strikingly, hybrid FS/CA-NF showed that perfluoro groups are rigidly positioned on the outer surface of the nanofibers providing superhydrophobic characteristic with a water contact angle of ∼155°. Detailed analysis showed that hydrolysis/condensation reactions led to the modification of the acetylated β(1 → 4) linked d-glucose chains of CA transforming it into a superhydrophobic nanofibrous mat. Analytical data have revealed that CA-NF surfaces can be selectively controlled for fabricating the durable, robust and water resistant hybrid electrospun nanofibrous mat. The -OH groups available on the CA structure allowed the basic sol-gel reactions started by the reactive FS hybrid precursor system which can be monitored by spectroscopic analysis. Since alkoxysilane groups on the perfluoro silane compound are capable of reacting for condensation together with the CA, superhydrophobic nanofibrous mat is obtained via electrospinning. This structural modification led to the facile fabrication of the novel oil/water nanofibrous separator which functions effectively demonstrated by hexane/oil and water separation experiments. Perfluoro groups consequently modified the hydrophilic CA nanofibers into superhydrophobic character and therefore FS/CA-NF could be quite practical for future applications like water/oil separators, as well as self-cleaning or water resistant nanofibrous structures.

  7. Effect of evaporation time on cellulose acetate membrane for gas separation

    NASA Astrophysics Data System (ADS)

    Jami'an, W. N. R.; Hasbullah, H.; Mohamed, F.; Yusof, N.; Ibrahim, N.; Ali, R. R.

    2016-06-01

    Throughout this decades, membrane technology has been the desirable option among the others gas separation technologies. However, few issues have been raised regarding the membrane gas separation application including the trade-off between its permeability and selectivity and also its effects towards environment. Therefore, for this research, a biopolymer membrane for gas separation application will be developed with reasonably high on both permeability and selectivity. The main objective of this research is to study the effect of solvent evaporation time on the flat sheet asymmetric membrane morphology and gas separation performance. The membranes were produced by a simple dry/wet phase inversion technique using a pneumatically controlled casting system. The dope solution for the membrane casting was prepared by dissolving the cellulose acetate (CA) polymer in N-Methyl-2-pyrrolidone (NMP) and the solvent evaporation time was varied. Permeability and selectivity of the membrane was performed by using pure gases of carbon dioxide, CO2 and methane, CH4. The increase in solvent evaporation time had improved the membrane morphologies as the porosity of the membrane surface decrease and formation of a more mature skin layer. The gas permeation tests determined that increasing in solvent evaporation time had increased the selectivity of CO2/CH4 but reduce the permeability of both gases

  8. Electrospun cellulose acetate nanofibers as thin layer chromatographic media for eco-friendly screening of steroids adulterated in traditional medicine and nutraceutical products.

    PubMed

    Rojanarata, Theerasak; Plianwong, Samarwadee; Su-uta, Kosit; Opanasopit, Praneet; Ngawhirunpat, Tanasait

    2013-10-15

    Nanofibers fabricated from cheap, naturally derived biopolymer, namely cellulose acetate via facile electrospinning technique were successfully applied for the first time to use as separation media for thin layer chromatography (TLC). From the optimization studies, uniform, bead-free nanofibers with good adherence to the backing plates were obtained by electrospinning 17% (w/v) cellulose acetate solution prepared in acetone/N,N-dimethylacetamide (2:1, v-v), using a feed rate of 0.6 mL/h and an electrostatic field strength of 17.5 kV/15 cm for 4h. The nanofibers exhibited reversed phase characteristics, thereby offering the possibility to use simple, polar and more environmental friendly mixtures of water and alcohols as mobile phase. In this work, the application of the fabricated fibers was illustrated by using them combined with the optimal mobile phase e.g. ethanol/water (40:60, v-v) for the screening of steroids adulterated in traditional medicine and nutraceutical products. Due to the satisfactory separation performance, electrospun cellulose acetate nanofibers were shown to be an efficient alternative for TLC media and could be potentially used for the development of green and facile analytical methods.

  9. Statistical learning of peptide retention behavior in chromatographic separations: a new kernel-based approach for computational proteomics

    PubMed Central

    Pfeifer, Nico; Leinenbach, Andreas; Huber, Christian G; Kohlbacher, Oliver

    2007-01-01

    Background High-throughput peptide and protein identification technologies have benefited tremendously from strategies based on tandem mass spectrometry (MS/MS) in combination with database searching algorithms. A major problem with existing methods lies within the significant number of false positive and false negative annotations. So far, standard algorithms for protein identification do not use the information gained from separation processes usually involved in peptide analysis, such as retention time information, which are readily available from chromatographic separation of the sample. Identification can thus be improved by comparing measured retention times to predicted retention times. Current prediction models are derived from a set of measured test analytes but they usually require large amounts of training data. Results We introduce a new kernel function which can be applied in combination with support vector machines to a wide range of computational proteomics problems. We show the performance of this new approach by applying it to the prediction of peptide adsorption/elution behavior in strong anion-exchange solid-phase extraction (SAX-SPE) and ion-pair reversed-phase high-performance liquid chromatography (IP-RP-HPLC). Furthermore, the predicted retention times are used to improve spectrum identifications by a p-value-based filtering approach. The approach was tested on a number of different datasets and shows excellent performance while requiring only very small training sets (about 40 peptides instead of thousands). Using the retention time predictor in our retention time filter improves the fraction of correctly identified peptide mass spectra significantly. Conclusion The proposed kernel function is well-suited for the prediction of chromatographic separation in computational proteomics and requires only a limited amount of training data. The performance of this new method is demonstrated by applying it to peptide retention time prediction in IP

  10. Combined cation-exchange and extraction chromatographic method of preconcentration and concomitant separation of bismuth(III) with high molecular mass liquid cation exchanger.

    PubMed

    Mandal, Bhabatosh; Ghosh, Niladri

    2010-10-15

    A selective method has been developed for the extraction chromatographic separation of Bi(III) with Versatic 10 coated on silanized silica gel (SSG). Bi(III) has been quantitatively extracted from 0.1 M acetate buffer at the range of pH 5.0-5.5. The result showed that the solution pH, influent volume, flow-rate and solution temperature would affect the sorption of Bi(III). The sorbed Bi(III) was eluted with 0.1 M H(2)SO(4). The extractor system has got good values of exchange capacity (1.42 meq. of H(+) g(-1) of dry exchanger at 25 degrees C), break-through capacity (19.75 mg g(-1) at pH 5.5) and column efficiencies (300) with respect to Bi(III). The positive value of DeltaH (12.63 kJ mol(-1)) and DeltaS (0.271 kJ mol(-1) K(-1)) and negative value of DeltaG (-68.241 kJ mol(-1)) indicated that the sorption process was endothermic, entropy gaining and spontaneous in nature. P.F. has been optimized at 76.4+/-0.3 and the desorption constants K(desorption) (8x10(-3)) and K'(desorption) (1.4x10(-1)) have been determined. R(f) values and selectivity factors for diverse metal ions with respect to that of Bi(III) have been determined by ion-exchange paper chromatography. Bi(III) has been separated from synthetic mixtures containing its congeners and other metal ions associated with it in ores and alloy samples. The method was found effective for removal of Bi(III) from different water samples. A plausible mechanism for the extraction of Bi(III) has been suggested.

  11. Robust isocratic liquid chromatographic separation of functional poly(methyl methacrylate).

    PubMed

    Jiang, Xulin; Lima, Vincent; Schoenmakers, Peter J

    2003-11-07

    The separation of telechelic poly(methyl methacrylate) (PMMA) prepolymers based on the number of end-groups under critical liquid chromatography (LC) conditions has been studied using a bare-silica column, which can interact with polar functional groups. The critical solvent compositions for non-functional, mono-functional and bi-functional PMMAs were determined in normal-phase LC using mixtures of acetonitrile and dichloromethane (DCM) of varying composition as the mobile phase. The telechelic prepolymers were successfully separated according to hydroxyl (OH) functionality (with zero, one, or two OH groups, respectively) under the critical conditions, in which fast (5 min), base-line separations were obtained independent of molecular weight. Changing the column temperature, flow rate, and mobile-phase composition within a certain range did not affect the functionality separation. Therefore this isocratic LC separation method is quite robust. Evaporative light-scattering detector (ELSD) calibration curves were used for the quantitative analysis of functional PMMA prepolymers.

  12. Comprehensive multi-dimensional liquid chromatographic separation in biomedical and pharmaceutical analysis: a review.

    PubMed

    Dixon, Steven P; Pitfield, Ian D; Perrett, David

    2006-01-01

    'Multi-dimensional' liquid separations have a history almost as long as chromatography. In multi-dimensional chromatography the sample is subjected to more than one separation mechanism; each mechanism is considered an independent separation dimension. The separations can be carried out either offline via fraction collection, or directly coupled online. Early multi-dimensional separations using combinations of paper chromatography, electrophoresis and gels, in both planar and columnar modes are reviewed. Developments in HPLC have increased the number of measurable analytes in ever more complex matrices, and this has led to the concept of 'global metabolite profiling'. This review focuses on the theory and practice of modern 'comprehensive' multi-dimensional liquid chromatography when applied to biomedical and pharmaceutical analysis.

  13. Single-walled carbon nanotube-based polymer monoliths for the enantioselective nano-liquid chromatographic separation of racemic pharmaceuticals.

    PubMed

    Ahmed, Marwa; Yajadda, Mir Massoud Aghili; Han, Zhao Jun; Su, Dawei; Wang, Guoxiu; Ostrikov, Kostya Ken; Ghanem, Ashraf

    2014-09-19

    Single-walled carbon nanotubes were encapsulated into different polymer-based monolithic backbones. The polymer monoliths were prepared via the copolymerization of 20% monomers, glycidyl methacrylate, 20% ethylene glycol dimethacrylate and 60% porogens (36% 1-propanol, 18% 1,4-butanediol) or 16.4% monomers (16% butyl methacrylate, 0.4% sulfopropyl methacrylate), 23.6% ethylene glycol dimethacrylate and 60% porogens (36% 1-propanol, 18% 1,4-butanediol) along with 6% single-walled carbon nanotubes aqueous suspension. The effect of single-walled carbon nanotubes on the chiral separation of twelve classes of pharmaceutical racemates namely; α- and β-blockers, antiinflammatory drugs, antifungal drugs, dopamine antagonists, norepinephrine-dopamine reuptake inhibitors, catecholamines, sedative hypnotics, diuretics, antihistaminics, anticancer drugs and antiarrhythmic drugs was investigated. The enantioselective separation was carried out under multimodal elution to explore the chiral recognition capabilities of single-walled carbon nanotubes using reversed phase, polar organic and normal phase chromatographic conditions using nano-liquid chromatography. Baseline separation was achieved for celiprolol, chlorpheniramine, etozoline, nomifensine and sulconazole under multimodal elution conditions. Satisfactory repeatability was achieved through run-to-run, column-to-column and batch-to-batch investigations. Our findings demonstrate that single-walled carbon nanotubes represent a promising stationary phase for the chiral separation and may open the field for a new class of chiral selectors.

  14. Design of chiral monochloro-s-triazine reagents for the liquid chromatographic separation of amino acid enantiomers.

    PubMed

    Brückner, H; Wachsmann, M

    2003-05-23

    A series of chiral derivatizing reagents (CDRs) was synthesized by nucleophilic replacement of one chlorine atom in cyanuric chloride (2,4,6-trichloro-1,3,5-triazine; s-triazine) by alkoxy (methoxy, butoxy, 1,1,1-trifluoroethoxy) or aryloxy groups (phenoxy, nitrophenoxy, phenylphenoxy, 4-methylcoumaryloxy), and displacement of a second chlorine by L-alanine amide, L-phenylalanine amide, L-proline tert.-butyl ester, or Boc-L-lysine tert.-butyl ester. Further, CDRs were investigated in which two chlorine atoms in cyanuric chloride were substituted consecutively by L-valine amide and L-phenylalanine amide. The resulting CDRs having a remaining reactive chlorine were tested for their capability of derivatizing DL-amino acids followed by liquid chromatographic separation of the resulting diastereomers.

  15. Single-walled carbon nanotubes as stationary phase in gas chromatographic separation and determination of argon, carbon dioxide and hydrogen.

    PubMed

    Safavi, Afsaneh; Maleki, Norooz; Doroodmand, Mohammad Mahdi

    2010-08-24

    A chromatographic technique is introduced based on single-walled carbon nanotubes (SWCNTs) as stationary phase for separation of Ar, CO(2) and H(2) at parts per million (ppm) levels. The efficiency of SWCNTs was compared with solid materials such as molecular sieve, charcoal, multi-walled carbon nanotubes and carbon nanofibers. The morphology of SWCNTs was optimized for maximum adsorption of H(2), CO(2) and Ar and minimum adsorption of gases such as N(2), O(2), CO and H(2)O vapour. To control temperature of the gas chromatography column, peltier cooler was used. Mixtures of Ar, CO(2) and H(2) were separated according to column temperature program. Relative standard deviation for nine replicate analyses of 0.2 mL H(2) containing 10 microL of each Ar or CO(2) was 2.5% for Ar, 2.8% for CO(2) and 3.6% for H(2). The interfering effects of CO, and O(2) were investigated. Working ranges were evaluated as 40-600 ppm for Ar, 30-850 ppm for CO(2) and 10-1200 ppm for H(2). Significant sensitivity, small relative standard deviation (RSD) and acceptable limit of detection (LOD) were obtained for each analyte, showing capability of SWCNTs for gas separation and determination processes. Finally, the method was used to evaluate the contents of CO(2) in air sample.

  16. Application of chiral derivatizing agents in the high-performance liquid chromatographic separation of amino acid enantiomers: a review.

    PubMed

    Ilisz, István; Berkecz, Robert; Péter, Antal

    2008-05-12

    The past 20 years has seen an explosive growth in the field of chirality, as illustrated by the rapid progress in the various facets of this intriguing field. The impetus for advances in chiral separation has been highest in the past decade and this still continues to be an area of high focus. This paper reviews indirect separation approaches, i.e. derivatization reactions aimed at creating the basis for the chromatographic resolution of biologically and pharmaceutically important enantiomers, with emphasis on the literature published in the last 12 years. The main aspects of the chiral derivatization of amino acids are discussed, i.e. derivatization on the amino group, transforming the molecules into covalently bonded diastereomeric derivatives through the use of homochiral derivatizing agents. The diastereomers formed (amides, urethanes, urea, thiourea derivatives, etc.) can be separated on achiral stationary phases. The applications are considered, and in some cases different derivatizing agents for the resolution of complex mixtures of proteinogenic d,l-amino acids, non-proteinogenic amino acids and peptides/amino acids from peptide syntheses or microorganisms are compared.

  17. Chromatographic separation of arsenic species with pentafluorophenyl column and application to rice.

    PubMed

    Baba, Koji; Arao, Tomohito; Yamaguchi, Noriko; Watanabe, Eiki; Eun, Heesoo; Ishizaka, Masumi

    2014-08-08

    Arsenic species, including arsenous acid, arsenic acid, methylarsonic acid, and dimethylarsinic acid, were determined using HPLC-ICPMS. The species were separated with a Discovery HS F5 column and a simple, volatile, and isocratic mobile phase of 0.1% (v/v) formic acid and 1% (v/v) methanol. The Discovery HS F5 column with a pentafluorophenyl (PFP) stationary phase gave sharp peaks and full separation of the arsenic species in 5min, and other PFP columns showed lower performance. This separation method was applied to arsenic species analysis in rice. The extraction of arsenic from rice samples was performed using 0.15M nitric acid. The methodology was validated by use of certified reference materials, NMIJ CRM 7503-a and NIST SRM 1568a, and extremely low arsenic rice samples as blank samples.

  18. Chromatographic separation of selenium and arsenic: A potential (72)Se/(72)As generator.

    PubMed

    Wycoff, Donald E; Gott, Matthew D; DeGraffenreid, Anthony J; Morrow, Ryan P; Sisay, Nebiat; Embree, Mary F; Ballard, Beau; Fassbender, Michael E; Cutler, Cathy S; Ketring, Alan R; Jurisson, Silvia S

    2014-05-02

    An anion exchange method was developed to separate selenium and arsenic for potential utility in a (72)Se/(72)As generator. The separation of the daughter (72)As from the (72)Se parent is based on the relative acid-base behavior of the two oxo-anions in their highest oxidation states. At pH 1.5, selenate is retained on strongly basic anion exchange resin as HSeO4(-) and SeO4(2-), while neutral arsenic acid, H3AsO4, is eluted.

  19. Chromatographic Separation of Selenium and Arsenic: A Potential 72Se/72As Generator

    PubMed Central

    Wycoff, Donald E.; Gott, Matthew D.; DeGraffenreid, Anthony J.; Morrow, Ryan P.; Sisay, Nebiat; Embree, Mary F.; Ballard, Beau; Fassbender, Michael E.; Cutler, Cathy S.; Ketring, Alan R.; Jurisson, Silvia S.

    2014-01-01

    Summary An anion exchange method was developed to separate selenium and arsenic for potential utility in a 72Se/72As generator. The separation of the daughter 72As from the 72Se parent is based on the relative acid-base behavior of the two oxo-anions in their highest oxidation states. At pH 1.5, selenate is retained on strongly basic anion exchange resin as HSeO4− and SeO42−, while neutral arsenic acid, H3AsO4, is eluted. PMID:24679827

  20. Exploration of zwitterionic cellulose acetate antifouling ultrafiltration membrane for bovine serum albumin (BSA) separation.

    PubMed

    Liu, Yang; Huang, Haitao; Huo, Pengfei; Gu, Jiyou

    2017-06-01

    This study focused on the preparation of a new kind of membrane material, zwitterionic cellulose acetate (ZCA), via a three-step procedure consist of oxidization, Schiff base and quaternary amination reaction, and the fabrication of antifouling ZCA ultrafiltration membrane by the non-solvent-induced phase separation method (NIPS). The morphologies, surface chemical structures and compositions of the obtained CA and ZCA membranes were thoroughly characterized by field emission scanning electron microscopy (FE-SEM) with energy dispersive X-ray (EDX) spectroscopy, Fourier transform infrared spectroscopy (FTIR) and X-ray photoelectron spectroscopy (XPS), respectively. Meanwhile, the thermal stability, porosity and average pore size of two investigated membranes were also studied. As a result, the ZCA membrane displayed significantly improved hydrophilicity and water permeability compared with those of the reference CA membrane, despite a slight decrease in the protein rejection ratio. According to the cycle ultrafiltration performance of bovine serum albumin (BSA) solution and protein adsorption experiment, ZCA membrane exhibited better flux recovery property and fouling resistant ability, especially irreversible fouling resistant ability, suggesting superior antifouling performance. This new approach gives polymer-based membrane a long time life and excellent ultrafiltration performance, and seems promising for potential applications in the protein separation.

  1. Thin-layer chromatographic (TLC) separations and bioassays of plant extracts to identify antimicrobial compounds

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungal spores in nutrient solution or bacteria in liquefied agar), allowing time for the microbes to gr...

  2. Ion-exchange chromatographic separation of einsteinium from irradiated californium targets

    SciTech Connect

    Elesin, A.A.; Nikolaev, V.M.; Shalimov, V.V.; Popov, Yu.S.; Kovantsev, V.N.; Tselishchev, I.V.; Filimonov, V.T.; Mishenev, V.B.; Yadovin, A.A.; Golosovskii, L.S.; Chetverikov, A.P.

    1987-07-01

    Einsteinium was obtained by preparing two experimental californium targets and subjecting them to neutron irradiation in a high-flux reactor. The einsteinium was separated from the bombarded targets on a column packed with KU-2U sulfonated cation-exchange resin (20-50 ..mu..m) and eluted at room temperature with an ammonium ..cap alpha..-hydroxyisobutyrate solution. Three successive separation cycles removed californium to produce einsteinium in 68% yield with a decontamination factor of 5.3 x 10/sup 6/. About 20% of the einsteinium was used up by analysis and 11% remained in intermediate fractions. The method developed yielded pure einsteinium with little fission products present. The contribution of the fission products to the total einsteinium gamma-irradiation dose rate was no greater than 81%, due primarily to the radioisotope terbium-160.

  3. Electrochemically modulated liquid chromatographic separation of triazines and the effect of pH on retention.

    PubMed

    Yakes, Betsy Jean; Keller, David W; Porter, Marc D

    2010-06-25

    Electrochemically modulated liquid chromatography (EMLC) manipulates analyte retention by changing the potential applied (E(app)) to a conductive stationary phase. This paper applies EMLC to the separation of a set of seven triazines which are commonly used but environmentally hazardous herbicides. Experiments herein examine the influence of E(app) and the pH of the mobile phase on triazine retention. The results are discussed in terms of: (1) retention of triazines of dissimilar acid strengths and by correlations with the pH of the mobile phase; (2) how changes in E(app) and acid-base equilibria modulate elution; (3) qualitative insights into EMLC-based retention; and (4) potential merits of EMLC in realizing the rapid separation of the seven-component triazine mixture.

  4. A Novel Micellar Electrokinetic Chromatographic Method for Separation of Metal-DDTC Complexes

    PubMed Central

    Mallah, Arfana; Memon, Saima Q.; Solangi, Amber R.; Memon, Najma; Abbassi, Kulsoom; Khuhawar, Muhammad Yar

    2012-01-01

    Micellar electrokinetic chromatography (MEKC) was examined for the separation and determination of Mo(VI), Cr(VI), Ni(II), Pd(II), and Co(III) as diethyl dithiocarbamate (DDTC) chelates. The separation was achieved from fused silica capillary (52 cm × 75 μm id) with effective length 40 cm, background electrolyte (BGE) borate buffer pH 9.1 (25 mM), CTAB 30% (100 mM), and 1% butanol in methanol (70 : 30 : 5 v/v/v) with applied voltage of −10 kV using reverse polarity. The photodiode array detection was achieved at 225 nm. The linear calibration for each of the element was obtained within 0.16–10 μg/mL with a limit of detection (LOD) 0.005–0.0167 μg/mL. The separation and determination was repeatable with relative standard deviation (RSD) within 2.4–3.3% (n = 4) in terms of migration time and peak height/peak area. The method was applied for the determination of Mo(VI) from potatoes and almond, Ni(II) from hydrogenated vegetable oil, and Co(III) from pharmaceutical preparations with RSD within 3.9%. The results obtained were checked by standard addition and rechecked by atomic absorption spectrometry. PMID:22649320

  5. Triticonazole enantiomers: Separation by supercritical fluid chromatography and the effect of the chromatographic conditions.

    PubMed

    He, Jianfeng; Fan, Jun; Yan, Yilun; Chen, Xiaodong; Wang, Tai; Zhang, Yaomou; Zhang, Weiguang

    2016-11-01

    Enantiomeric pairs of triticonazole have been successfully separated by supercritical fluid chromatography coupled with a tris(3,5-dimethylphenylcarbamoyl) cellulose-coated chiral stationary phase in this work. The effects of co-solvent, dissolution solvent, flow rate, backpressure, and column temperature have been studied in detail with respect to retention, selectivity, and resolution of triticonazole. As indicated, the co-solvents mostly affected the retention factors and resolution, due to the different molecular structure and polarity. In addition, the dissolution solvents, namely, chloromethanes and alcohols, have been also important for enantioseparation because of the different interaction with stationary phase. Higher flow rate and backpressure led to faster elution of the triticonazole molecules, and the change of column temperature showed slight effect on the resolution of triticonazole racemate. Moreover, a comparative separation experiment between supercritical fluid chromatography and high performance liquid chromatography revealed that chiral supercritical fluid chromatography gave the 3.5 times value of Rs /tR2 than high performance liquid chromatography, which demonstrated that supercritical fluid chromatography had much higher separation efficiency.

  6. Separation of statistical poly[(N-vinyl pyrrolidone)-co-(vinyl acetate)]s by reversed-phase gradient liquid chromatography.

    PubMed

    Cheng, Guanglou; Cullen, Jim; Wu, Chi-san

    2011-01-14

    Although size exclusion chromatography (SEC) has been used successfully to determine the molecular weight distribution (MWD) of statistical poly[(N-vinyl pyrrolidone)-co-(vinyl acetate)]s [PVPVAs], SEC cannot separate the copolymers according to their chemical composition. In this article, the separation of commercial PVPVAs with varying chemical compositions is reported, by aqueous reversed-phase gradient liquid chromatography (RPLC) using polystyrene-divinylbenzene-based wide pore columns. RPLC-SEC cross-fractionation indicates the presence of molar mass dependant effects during RPLC separation due to broad MWD for the copolymer studied; therefore the width of the RPLC peak could not be associated entirely with chemical composition distribution of the copolymer. Coupling of RPLC with online FTIR spectroscopy reveals the increase of VA content with increasing THF gradient, an indication of interaction mechanism between VA repeating units and the stationary phase for water soluble PVPVAs. Separation of water insoluble PVPVAs and PVAs by the RPLC are possibly based on both interaction and precipitation/redissolution mechanisms.

  7. Optimization to eliminate the interference of migration isomers for measuring 1-O-beta-acyl glucuronide without extensive chromatographic separation.

    PubMed

    Xue, Y-J; Akinsanya, J Billy; Raghavan, Nirmala; Zhang, Donglu

    2008-01-01

    A highly selected reaction monitoring (SRM) method has been investigated for the determination of muraglitazar 1-O-beta-acyl glucuronide in animal and human plasma without chromatographic separation of this naturally formed acyl glucuronide from its migration isomers. In the ion source or the collision cell, glucuronides are often prone to lose the dehydrated glucuronic acid (176 Da) and convert back into the parent drug (aglycone). The extent of loss of the glucuronide moiety can differ among glucuronides. For the naturally occurring muraglitazar 1-O-beta-acyl glucuronide, or its synthetic anomer 1-O-alpha-glucuronide, the loss of the glucuronide moiety was a major fragment ion. The loss of the glucuronide moiety was greater for the 1-O-beta-acyl glucuronide than the 1-O-alpha-anomer. In addition, the loss of the glucuronide moiety was insignificant (less than 0.01%) with the other glucuronide isomers (2-, 3- or 4-O, alpha or beta). Given the fact that the 1-O-alpha-anomer was a minor impurity in the muraglitazar 1-O-beta-acyl glucuronide reference standard, and not either a conversion product of 1-O-beta-acyl glucuronide or endogenously formed, the SRM transition corresponding to the loss of the glucuronide moiety was very specific for 1-O-beta-acyl glucuronide, and practically free from interference of the other isomers under optimized collision-cell conditions. As a result, extensive chromatographic separation of 1-O-beta-acyl glucuronide from its migration isomers was not required. The use of this specific SRM transition effectively reduced the separation time from 12.0 min of a long-column high-performance liquid chromatography (HPLC) method to 2.5 min by use of a shorter column. The standard curve performance and analysis results of 1-O-beta-acyl glucuronide incubation samples showed that the short-column method could produce equivalent results to the long-column method but with a 4.5-fold improvement in sample throughput. This approach may be useful for

  8. Determination of mercurial species in fish by inductively coupled plasma mass spectrometry with anion exchange chromatographic separation.

    PubMed

    Chen, Xiaopan; Han, Chao; Cheng, Heyong; Liu, Jinhua; Xu, Zigang; Yin, Xuefeng

    2013-09-24

    This work demonstrated the feasibility of mercury speciation analysis by anion exchange chromatographic separation with inductively coupled plasma mass spectrometry detection. For the first time, by complexing with the mobile phase containing 3-mercapto-1-propanesulfonate into negatively charged complexes, fast separation of inorganic mercury (Hg(2+)), monomethylmercury (MeHg), ethylmercury (EtHg) and phenylmercury (PhHg) was achieved within 5 min on a 12.5-mm strong anion exchange column. The detection limits for Hg(2+), MeHg, EtHg and PhHg were 0.008, 0.024, 0.029 and 0.034 μg L(-1), respectively. The relative standard deviations of peak height and peak area (5.0 μg L(-1) for each Hg species) were all below 3%. The determined contents of Hg(2+), MeHg and total Hg in a certified reference material of fish tissue by the proposed method were in good accordance with the certified values with satisfactory recoveries. The relative errors for determining MeHg and total mercury were -2.4% and -1.2%, respectively, with an acceptable range for spike recoveries of 94-101%. Mercury speciation in 11 fish samples were then analyzed after the pretreated procedure. The mercury contents in all fish samples analyzed were found compliant with the criteria of the National Standards of China.

  9. A low-power pressure-and temperature-programmed separation system for a micro gas chromatograph.

    SciTech Connect

    Sacks, Richard D. (University of Michigan, Ann Arbor, MI); Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Lambertus, Gordon R. (University of Michigan, Ann Arbor, MI); Potkay, Joseph A. (University of Michigan, Ann Arbor, MI); Wise, Kensall D. (University of Michigan, Ann Arbor, MI)

    2006-10-01

    This thesis presents the theory, design, fabrication and testing of the microvalves and columns necessary in a pressure- and temperature-programmed micro gas chromatograph ({micro}GC). Two microcolumn designs are investigated: a bonded Si-glass column having a rectangular cross section and a vapor-deposited silicon oxynitride (Sion) column having a roughly circular cross section. Both microcolumns contain integrated heaters and sensors for rapid, controlled heating. The 3.2 cm x 3.2 cm, 3 m-long silicon-glass column, coated with a non-polar polydimethylsiloxane (PDMS) stationary phase, separates 30 volatile organic compounds (VOCs) in less than 6 min. This is the most efficient micromachined column reported to date, producing greater than 4000 plates/m. The 2.7 mm x 1.4 mm Sion column eliminates the glass sealing plate and silicon substrate using deposited dielectrics and is the lowest power and fastest GC column reported to date; it requires only 11 mW to raise the column temperature by 100 C and has a response time of 11s and natural temperature ramp rate of 580 C/min. A 1 m-long PDMS-coated Sion microcolumn separates 10 VOCs in 52s. A system-based design approach was used for both columns.

  10. Discovery of active components in herbs using chromatographic separation coupled with online bioassay.

    PubMed

    De-Qiang, Li; Zhao, Jing; Wu, Dong; Shao-Ping, Li

    2016-05-15

    Discovery of bioactive compounds from complex mixtures is a challenge. In past decades, several strategies were developed and implemented for rapid and effective screening and characterization of bioactive components in complex matrices. This review mainly focused on the online strategies, which integrated the separation science, mass spectrometry, and bioactivity screening in a single platform, allowing simultaneous screening and characterization of active compounds from complex matrices, especially from the herbs. The online screening methodologies, including pre-column affinity-based screening and post-column bioassay, were discussed and their applied examples were also presented to illustrate the strengths and limitations of these approaches.

  11. Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator.

    PubMed

    Collin, William R; Nuñovero, Nicolas; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-04-29

    Comprehensive two-dimensional gas chromatography (GC×GC) with a temperature-programmed microfabricated thermal modulator (μTM) is demonstrated. The 0.78 cm(2), 2-stage μTM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension ((1)D) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension ((2)D) PEG-coated capillary. A mixture of n-alkanes C6-C10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of μTM, Tmin and Tmax, respectively. With Tmin and Tmax fixed at -25 and 100°C, respectively, modulated peaks of C6 and C7 had fwhm values<53 ms while the modulated peaks of C10 had a fwhm value of 1.3s, due to inefficient re-mobilization. With Tmin and Tmax fixed at 0 and 210°C, respectively, the fwhm value for the modulated C10 peaks decreased to 67 ms, but C6 and C7 exhibited massive breakthrough. By programming Tmin from -25 to 0°C and Tmax from 100 to 220°C, the C6 and C7 peaks had fwhm values≤50 ms, and the fwhm for C10 peaks remained<95 ms. Using the latter conditions for the GC×GC separation of a sample of unleaded gasoline yielded resolution similar to that reported with a commercial thermal modulator. Replacing the PDMS phase in the μTM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource μTM enhances its versatility and its promise for use in bench-scale GC×GC systems.

  12. Evaluation of two approaches to characterise liquid chromatographic columns using pharmaceutical separations.

    PubMed

    Dragovic, Sanja; Haghedooren, Erik; Németh, Tamás; Palabiyik, I Murat; Hoogmartens, Jos; Adams, Erwin

    2009-04-10

    In this paper a comparison of two column characterisation systems is reported: the method based on the hydrophobic-subtraction model of Dolan and Snyder (HS method) versus the method developed at the Katholieke Universiteit Leuven (KUL method). Comparison was done for seven different pharmaceutical separations (fluoxetine, gemcitabine, erythromycin, tetracycline, tetracaine, amlodipine and bisacodyl), using a set of 59 columns. A ranking was built based on an F value (KUL) or F(s) value (HS) versus a (virtual) reference column. Both methods showed similar probabilities of ranking patterns. Correlation of the respective test parameters of both approaches was poor. Both methods are not perfect and do not match well, but anyhow yield results which allow, with a relatively high certainty, the selection of similar or dissimilar columns as compared to a reference column. An analyst that uses either of the two methods will end up with a similar probability to choose an adequate column. From a practical point of view, it must be noted that the KUL method is easier to use.

  13. Preparation of weak cation exchange packings for chromatographic separation of proteins using "click chemistry''.

    PubMed

    Zhao, Kailou; Bai, Quan; Song, Chao; Wang, Fei; Yang, Fan

    2012-04-01

    "Click chemistry" is defined as a class of robust and selective chemical reactions affording high yields and is tolerant to a variety of solvents (including water), functional groups, and air. In this study, click chemistry was used as an effective strategy for coupling three alkyne-carboxylic acids onto the azide-silica to obtain three novel stationary phases of weak cation exchange chromatography, which were characterized with FTIR and elemental analysis. Six kinds of standard proteins, such as myoglobin, RNase A, RNase B, cytochrome C, α-chymotrypsin A, and lysozyme, were separated completely with the three novel weak cation exchange chromatography stationary phases. Compared with commercial weak cation exchange chromatography columns, the three kinds of novel weak cation exchange chromatography packings prepared by click chemistry approach have better resolution and selectivity. The mass recovery of more than 97% was obtained for all the tested proteins, and the bioactivity recovery of lysozyme on the prepared column was determined to be 96%. In addition, lysozyme was purified successfully from egg white with the novel weak cation exchange chromatography column by one step. The purity was more than 97% and a high specific activity was achieved to be 81 435 U/mg. The results illustrate the potential of click chemistry for preparing stationary phase for ion-exchange chromatography.

  14. Study of polydimethylsiloxane/aromatic polyamide laminated membranes for separation of acetic acid/water mixtures by pervaporation process

    SciTech Connect

    Deng, S.; Sourirajan, S.; Matsuura, T. )

    1994-06-01

    Separation of acetic acid/water mixtures by pervaporation was attempted over a range of compositions using polydimethylsiloxane (PDMS), aromatic polyamide (PA), and laminated polydimethylsiloxane-aromatic polyamide membranes. PDMS membranes are hydrophobic and acetic acid selective, whereas PA membranes are hydrophilic and water selective. When PDMS and PA membranes were laminated, with PDMS on the top side and in contact with the feed, water selectivity of the bottom PA membrane was intensified. On the other hand, when the PA membrane was on the top side and in contact with the feed, the selectivity was lowered. 10 refs., 4 figs.

  15. Quantitative Mass Spectrometric Analysis of Ropivacaine and Bupivacaine in Authentic, Pharmaceutical and Spiked Human Plasma without Chromatographic Separation

    PubMed Central

    Salama, Nahla N.; Wang, Shudong

    2009-01-01

    The present study employs time of flight mass and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL−1 for both drugs. The correlation coefficient was ≥0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%–102.75% was obtained. The method is accurate (% RE < 5%) and reproducible with intra- and inter-assay precision (RSD% < 8.0%). The quantification limit is 23.8 ng mL−1 for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs. PMID:19652756

  16. Quantitative mass spectrometric analysis of ropivacaine and bupivacaine in authentic, pharmaceutical and spiked human plasma without chromatographic separation.

    PubMed

    Salama, Nahla N; Wang, Shudong

    2008-05-28

    The present study employs time of flight mass and bupivacaine in authentic, pharmaceutical and spiked human plasma as well as in the presence of their impurities 2,6-dimethylaniline and alkaline degradation product. The method is based on time of flight electron spray ionization mass spectrometry technique without preliminary chromatographic separation and makes use of bupivacaine as internal standard for ropivacaine, which is used as internal standard for bupivacaine. A linear relationship between drug concentrations and the peak intensity ratio of ions of the analyzed substances is established. The method is linear from 23.8 to 2380.0 ng mL(-1) for both drugs. The correlation coefficient was >or=0.996 in authentic and spiked human plasma. The average percentage recoveries in the ranges of 95.39%-102.75% was obtained. The method is accurate (% RE < 5%) and reproducible with intra- and inter-assay precision (RSD% < 8.0%). The quantification limit is 23.8 ng mL(-1) for both drugs. The method is not only highly sensitive and selective, but also simple and effective for determination or identification of both drugs in authentic and biological fluids. The method can be applied in purity testing, quality control and stability monitoring for the studied drugs.

  17. Highly Porous Regenerated Cellulose Fiber Mats via the Co-Forcespinning of Cellulose Acetate for Separator Applications

    NASA Astrophysics Data System (ADS)

    Castillo, Alejandro; Mao, Yuanbing

    2015-03-01

    Improvements in battery technology are necessary for the transition away from a fossil fuel based economy. An important bottle-neck in battery efficiency is the quality of the separator, which separates the cathode and anode to prevent a short-circuit while still allowing the ions in solution to flow as close to unabated as possible. In this work solutions of cellulose acetate, polyvinyldiflourine (pvdf), and polyvinylpyrrolidone (pvp) dissolved in a 2:1 v/v acetone/dimethylacetamide solvent mixture were Forcespun to create nonwoven fiber mats of nanoscale diameter. These mats were then soaked in a NaOH solution so as to both strip the pvp from the fiber as well as regenerate cellulose from its acetate derivative for the purpose of creating high surface area, nanoporous, hydrophilic, and ioniclly conductive cellulose/pvdf nonwoven mats for the purposes of testing their suitability as battery separators

  18. High-performance liquid chromatographic separation of paclitaxel intermediate phenylisoserine derivatives on macrocyclic glycopeptide and cyclofructan-based chiral stationary phases.

    PubMed

    Ilisz, István; Grecsó, Nóra; Forró, Enikő; Fülöp, Ferenc; Armstrong, Daniel W; Péter, Antal

    2015-10-10

    High-performance liquid chromatographic methods were developed for the separation of enantiomers of four unnatural paclitaxel precursor phenylisoserine analogs on chiral stationary phases containing macrocyclic glycopeptides and cyclofructans as chiral selectors. The effects of the mobile phase composition, the nature and concentration of different mobile phase additives (alcohols, amines and acids) in different chromatographic modes, temperature and the structures of the analytes on the separations were investigated. Separations were carried out at constant mobile phase compositions in the temperature range 10-50°C on macrocyclic antibiotic-based and 5-35°C on cyclofructan-based columns and the changes in enthalpy, Δ(ΔH°), entropy, Δ(ΔS°), and free energy, Δ(ΔG°), were calculated. The elution sequence was determined in most cases; no general rule could be observed.

  19. Gas chromatographic separation of fatty acid esters of cholesterol and phytosterols on an ionic liquid capillary column.

    PubMed

    Hammann, Simon; Vetter, Walter

    2015-12-15

    Steryl esters are high molecular weight compounds (600-700g/mol) regularly present as a minor lipid class in animal and plant lipids. Different sterol backbones (e.g., cholesterol, β-sitosterol and brassicasterol) which can be esterified with various fatty acids can result in highly complex steryl ester patterns in food samples. The gas chromatographic (GC) analysis of intact steryl esters is challenging, since high elution temperatures are required for their elution. On nonpolar GC phases, steryl esters with fatty acids with differing degree of unsaturation (e.g., oleate and linoleate) cannot be separated and there are only few polar columns available with sufficient temperature stability. In this study, we used gas chromatography with mass spectrometry (GC/MS) and analyzed intact steryl esters on a commercial room temperature ionic liquid (RTIL) column which was shortened to a length of 12m. The column separated the steryl esters both by total carbon number and by degree of unsaturation of the fatty acid. For instance, cholesteryl esters with stearic acid (18:0), oleic acid (18:1n-9), linoleic acid (18:2n-6) and α-linolenic acid (18:3n-3) could be resolved (R≥1.3) from each other. By analysis of synthesized standard substances, the elution orders for different steryl backbones and different fatty acids on a given sterol backbone could be determined. Analysis of spreads and plant oils allowed to determine retention times for 37 steryl esters, although a few co-elutions were observed. The ionic liquid column proved to be well-suited for the analysis of intact steryl esters.

  20. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    PubMed

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Sorption characteristics and chromatographic separation of gold (I and III) from silver and base metal ions using polyurethane foams.

    PubMed

    Farag, A B; Soliman, M H; Abdel-Rasoul, O S; el-Shahawi, M S

    2007-10-10

    The influence of different parameters on the sorption profiles of trace and ultra traces of gold (I) species from the aqueous cyanide media onto the solid sorbents ion exchange polyurethane foams (IEPUFs) and commercial unloaded polyurethane foams (PUFs) based polyether type has been investigated. The retention of gold (I) species onto the investigated solid sorbents followed a first-order rate equation with an overall rate constant k in the range 2.2-2.8+/-0.2 s(-1). The sorption data of gold (I) followed Freundlich and Langmuir isotherm models. Thus, the a dual-mode of sorption mechanism involving absorption related to "weak base anion exchanger" and an added component for "surface adsorption" seems the most likely proposed dual mechanism for retention profile of gold (I) by the IEPUFs and PUFs solid sorbents. The capacity of the IEPUFs and PUFs towards gold (I) sorption calculated from the sorption isotherms was found to be 11.21+/-1.8 and 5.29+/-0.9 mg g(-1), respectively. The chromatographic separation of the spiked inorganic gold (I) from de ionized water at concentrations 5-15 microg mL(-1) onto the developed IEPUFs and PUFs packed columns at 10 mL min(-1) flow rate was successfully achieved. The retained gold (I) species were then recovered quantitatively from the IEPUFs (98.4+/-2.4%, n=5) and PUFs (95.4+/-3.4%, n=5) packed columns using perchloric acid (60 mL, 1.0 mol L(-1)) as a proper eluting agent. Thiourea (1.0 mol L(-1))-H2SO4 (0.1 mol L(-1)) system was also used as eluting agent for the recovery of gold (I) from IEPUFS (95.4+/-5.4%, n=3) and also PUFs (93.4+/-4.4%, n=3) packed columns. The performance of the IEPUFs and PUFs packed columns in terms of the height equivalent to the theoretical plates (HETP), number of plates (N), and critical and breakthrough capacities towards gold (I) species were evaluated. The developed IEPUFs packed column was applied successfully for complete retention and recovery (98.5+/-2.7) of gold (III) species spiked onto

  2. High performance liquid chromatography/ion-trap mass spectrometry for separation and simultaneous determination of ethynylestradiol, gestodene, levonorgestrel, cyproterone acetate and desogestrel.

    PubMed

    Matejícek, David; Kubán, Vlastimil

    2007-04-11

    A fast and highly sensitive high performance liquid chromatographic/ion-trap mass spectrometric method (LC/MS) has been developed for simultaneous determination of ethynylestradiol (EE2), gestodene (GES), levonorgestrel (LNG), cyproterone acetate (CPA) and desogestrel (DES). Among three types of sorbents tested (C8, C18 and phenyl) from two suppliers, the best separation was achieved on reverse phase Zorbax SB-Phenyl column using aqueous methanol as a mobile phase. A linear gradient profile from 70 up to 100% (v/v) in 7th min, kept constant at 100% up to 10th min and followed by a negative gradient to 70% of methanol up to 12th min was used for elution. Applicability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) and influence of the mobile phase composition, its flow rate, capillary/vaporizer temperature of API source and in-source fragmentor voltage ionization are discussed. The on-column limits of quantification (10S/N) were 300 pg of EE2, 14 pg of GES and LNG, 4 pg of CPA and 960 pg of DES per injection (1 microL) using APCI with data collection in selected ion monitoring (SIM) mode. The analytical performance of the method was evaluated using the determination of EE2, GES, LNG, CPA and DES in contraceptives and river water samples.

  3. Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems

    PubMed Central

    Shinomiya, Kazufusa; Sato, Kazuki; Yoshida, Kazunori; Tokura, Koji; Maruyama, Hiroshi; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2013-01-01

    Universal high-speed counter-current chromatograph (HSCCC) was newly designed and fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2 cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanol/water and aqueous 0.1 M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products. PMID:24267319

  4. Partition efficiencies of newly fabricated universal high-speed counter-current chromatograph for separation of two different types of sugar derivatives with organic-aqueous two-phase solvent systems.

    PubMed

    Shinomiya, Kazufusa; Sato, Kazuki; Yoshida, Kazunori; Tokura, Koji; Maruyama, Hiroshi; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2013-12-27

    A new design of universal high-speed counter-current chromatograph (HSCCC) was fabricated in our laboratory. It holds a set of four column holders symmetrically around the rotary frame at a distance of 11.2cm from the central axis. By engaging the stationary gear on the central axis of the centrifuge to the planetary gears on the column holder shaft through a set of idle gears, two pairs of diagonally located column holders simultaneously rotate about their own axes in the opposite directions: one forward (type-J planetary motion) and the other backward (type-I planetary motion) each synchronously with the revolution. Using the eccentric coil assembly, partition efficiencies produced by these two planetary motions were compared on the separation of two different types of sugar derivatives (4-methylumbelliferyl and 5-bromo-4-chloro-3-indoxyl sugar derivatives) using organic-aqueous two-phase solvent systems composed of n-hexane/ethyl acetate/1-butanol/methanol/water and aqueous 0.1M sodium tetraborate, respectively. With lower phase mobile, better peak resolution was obtained by the type-J forward rotation for both samples probably due to higher retention of the stationary phase. With upper phase mobile, however, similar peak resolutions were obtained between these two planetary motions for both sugar derivatives. The overall results indicate that the present universal HSCCC is useful for counter-current chromatographic separation since each planetary motion has its specific applications: e.g., vortex CCC by the type-I planetary motion and HSCCC by the type-J planetary motion both for separation of various natural and synthetic products.

  5. High-resolution hydrodynamic chromatographic separation of large DNA using narrow, bare open capillaries: a rapid and economical alternative technology to pulsed-field gel electrophoresis?

    PubMed

    Liu, Lei; Veerappan, Vijaykumar; Pu, Qiaosheng; Cheng, Chang; Wang, Xiayan; Lu, Liping; Allen, Randy D; Guo, Guangsheng

    2014-01-07

    A high-resolution, rapid, and economical hydrodynamic chromatographic (HDC) method for large DNA separations in free solution was developed using narrow (5 μm diameter), bare open capillaries. Size-based separation was achieved in a chromatographic format with larger DNA molecules being eluting faster than smaller ones. Lambda DNA Mono Cut Mix was baseline-separated with the percentage resolutions generally less than 9.0% for all DNA fragments (1.5 to 48.5 kbp) tested in this work. High efficiencies were achieved for large DNA from this chromatographic technique, and the number of theoretical plates reached 3.6 × 10(5) plates for the longest (48.5 kbp) and 3.7 × 10(5) plates for the shortest (1.5 kbp) fragments. HDC parameters and performances were also discussed. The method was further applied for fractionating large DNA fragments from real-world samples (SacII digested Arabidopsis plant bacterial artificial chromosome (BAC) DNA and PmeI digested Rice BAC DNA) to demonstrate its feasibility for BAC DNA finger printing. Rapid separation of PmeI digested Rice BAC DNA covering from 0.44 to 119.041 kbp was achieved in less than 26 min. All DNA fragments of these samples were baseline separated in narrow bare open capillaries, while the smallest fragment (0.44 kbp) was missing in pulsed-field gel electrophoresis (PFGE) separation mode. It is demonstrated that narrow bare open capillary chromatography can realize a rapid separation for a wide size range of DNA mixtures that contain both small and large DNA fragments in a single run.

  6. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    PubMed

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines.

  7. Refined separation of combined Fe–Hf from rock matrices for isotope analyses using AG-MP-1M and Ln-Spec chromatographic extraction resins

    PubMed Central

    Cheng, Ting; Nebel, Oliver; Sossi, Paolo A.; Chen, Fukun

    2014-01-01

    A combined procedure for separating Fe and Hf from a single rock digestion is presented. In a two-stage chromatographic extraction process, a purified Fe fraction is first quantitatively separated from the rock matrix using AG-MP-1M resin in HCl. Hafnium is subsequently isolated using a modified version of a commonly applied method using Eichrom LN-Spec resin. Our combined method includes:•Purification of Fe from the rock matrix using HCl, ready for mass spectrometric analysis.•Direct loading of the matrix onto the resin that is used for Hf purification.•Collection of a Fe-free Hf fraction. PMID:26150946

  8. Low cost hydrogen/novel membrane technology for hydrogen separation from synthesis gas, Phase 1. [Polyetherimide, cellulose acetate and ethylcellulose

    SciTech Connect

    Not Available

    1986-01-01

    The goal of this program is to develop polymer membranes useful in the preparation of hydrogen from coal-derived synthesis gas. During this quarter the first experiment were aimed at developing high performance composite membranes for the separation of hydrogen from nitrogen and carbon monoxide. Three polymers have been selected as materials for these membranes: polyetherimide cellulose acetate and ethylcellulose. This quarter the investigators worked on polyetherimide and cellulose acetate membranes. The overall structure of these membranes is shown schematically in Figure 1. As shown, a microporous support membrane is first coated with a high flux intermediate layer then with an ultrathin permselective layer and finally, if necessary, a thin protective high flux layer. 1 fig., 4 tabs.

  9. Poly(triallyl isocyanurate-co-ethylene dimethacrylate-co-alkyl methacrylate) stationary phases in the chromatographic separation of hydrophilic solutes.

    PubMed

    Lin, Cheng-Lan; Singco, Brenda; Wu, Ching-Yi; Liang, Pei-Zhu; Cheng, Yi-Jie; Huang, Hsi-Ya

    2013-01-11

    This study describes the ability of triallyl isocyanurate (TAIC)-co-methacrylate ester polymer monoliths as stationary phases for the separation of hydrophilic compounds (phenolic acids, amino acids and catecholamines) in capillary electrochromatography (CEC) and ultra high pressure liquid chromatography (UHPLC). Several TAIC-co-methacrylate ester polymer monoliths prepared by single-step in situ copolymerization of TAIC, ethylene dimethacrylate (EDMA) and 2-acrylamido-2-methylpropane sulfonic acid (AMPS), with or without alkyl methacrylates were characterized by examining the SEM image, surface area, contact angle, and the thermal decomposition temperature. Compared to the conventional methacrylate ester-based monoliths, these proposed monoliths possessed hydrophilic character thus increased wettability which improved chromatographic separation selectivity of polar phenolic acids. Among the proposed TAIC-co-methacrylate monoliths, poly(TAIC-co-EDMA-AMPS-co-stearyl methacrylate (SMA)) showed separation selectivity with an increased analyte resolution from 0.0 to 0.92 for 4-hydroxybenzoic acid and vanillic acid, which were consistently difficult to resolve in the reversed-phase chromatographic mechanism of these monoliths in aqueous mobile phases. Moreover, stable ionization efficiencies were observed when this monolith was combined with ESI-MS detector possibly because an organic solvent-rich sheath liquid was used in the CEC-MS. This study demonstrates the potentiality of novel TAIC-co-methacrylate polymer monoliths in hydrophilic solute separation either in CEC or UHPLC mode.

  10. Metal-Organic Frameworks for Thin-Layer Chromatographic Applications.

    PubMed

    Schenk, Claudia; Kutzscher, Christel; Drache, Franziska; Helten, Stella; Senkovska, Irena; Kaskel, Stefan

    2017-01-25

    Preparation of thin-layer chromatographic (TLC) plates based on metal-organic frameworks (MOFs) as porous stationary phases is described. DUT-67 (DUT = Dresden University of Technology), a zirconium based MOF, was used in combination with a fluorescent indicator as stationary phase for analyzing a small selection of a wide spectrum of relevant analytes. The successful separation of benzaldehyde from trans-cinnamaldehyde and 4-aminophenol from 2-aminotoluene is reported as a model system using optimized eluent mixtures containing acetic acid.

  11. Modified normal-phase ion-pair chromatographic methods for the facile separation and purification of imidazolium-based ionic compounds

    SciTech Connect

    Urban, ND; Schenkel, MR; Robertson, LA; Noble, RD; Gin, DL

    2012-07-04

    lmidazolium- and oligo(imidazolium)-based ionic organic compounds are important in the design of room-temperature ionic liquid materials; however, the chromatographic analysis and separation of such compounds are often difficult. A convenient and inexpensive method for effective thin-layer chromatography (TLC) analysis and column chromatography separation of imidazolium-based ionic compounds is presented. Normal-phase ion-pair TLC is used to effectively analyze homologous mixtures of these ionic compounds. Subsequent separation of the mixtures is performed using ion-pair flash chromatography on normal-phase silica gel, yielding high levels of recovery. This method also results in a complete exchange of the counter anion on the imidazolium compounds to the anion of the ion-pair reagent. (C) 2012 Elsevier Ltd. All rights reserved.

  12. Separation of the fatty acids in menhaden oil as methyl esters with a highly polar ionic liquid gas chromatographic column and identification by time of flight mass spectrometry.

    PubMed

    Fardin-Kia, Ali Reza; Delmonte, Pierluigi; Kramer, John K G; Jahreis, Gerhard; Kuhnt, Katrin; Santercole, Viviana; Rader, Jeanne I

    2013-12-01

    The fatty acids contained in marine oils or products are traditionally analyzed by gas chromatography using capillary columns coated with polyethylene glycol phases. Recent reports indicate that 100 % cyanopropyl siloxane phases should also be used when the analyzed samples contain trans fatty acids. We investigated the separation of the fatty acid methyl esters prepared from menhaden oil using the more polar SLB-IL111 (200 m × 0.25 mm) ionic liquid capillary column and the chromatographic conditions previously optimized for the separation of the complex mixture of fatty acid methyl esters prepared from milk fat. Identifications of fatty acids were achieved by applying Ag(+)-HPLC fractionation and GC-TOF/MS analysis in CI(+) mode with isobutane as the ionization reagent. Calculation of equivalent chain lengths confirmed the assignment of double bond positions. This methodology allowed the identification of 125 fatty acids in menhaden oil, including isoprenoid and furanoid fatty acids, and the novel 7-methyl-6-hexadecenoic and 7-methyl-6-octadecenoic fatty acids. The chromatographic conditions applied in this study showed the potential of separating in a single 90-min analysis, among others, the short chain and trans fatty acids contained in dairy products, and the polyunsaturated fatty acids contained in marine products.

  13. Catalyst assisted synthesis of initiator attached silica monolith particles via isocyanate-hydroxyl reaction for production of polystyrene bound chromatographic stationary phase of excellent separation efficiency.

    PubMed

    Ali, Faiz; Kim, Yune Sung; Lee, Jin Wook; Cheong, Won Jo

    2014-01-10

    Dibutyltin dichloride (DBTDC) was used as a catalyst to chemically bind 4-chloromehtylphenylisocynate (4-CPI) to porous monolithic silica particles via isocyanate-hydroxyl reaction, and the reaction product was reacted with sodium diethyldithiocarbamate (SDDC) to yield initiator attached silica monolith particles. Reversible addition-fragmentation transfer (RAFT) polymerization was taken place on them to result in polystyrene attached silica particles that showed excellent separation efficiency when packed in a chromatographic column (1.0 mm × 300 mm). The numbers of theoretical plates (N) of 56,500 is better than those of any commercially available HPLC or UHPLC column yet.

  14. Direct quantitative gas chromatographic separation of C2-C6 fatty acids, methanol, and ethyl alcohol in aqueous microbial fermentation media.

    PubMed

    Rogosa, M; Love, L L

    1968-02-01

    A method is described for the direct quantitative gas chromatographic separation of C(2)-C(6) lower fatty acid homologues, methanol, and ethyl alcohol in aqueous microbial fermentation media. A hydrogen flame detector and a single-phase solid column packing, comprising beads of a polyaromatic resin (polystyrene cross-linked with divinyl benzene), were employed. Direct injections of 1 to 10 muliters of aqueous culture supernatant fluids were made. Quantitative recoveries of C(2)-C(6) acids added to culture supernatant fluids were obtained.

  15. Direct Quantitative Gas Chromatographic Separation of C2-C6 Fatty Acids, Methanol, and Ethyl Alcohol in Aqueous Microbial Fermentation Media

    PubMed Central

    Rogosa, M.; Love, L. L.

    1968-01-01

    A method is described for the direct quantitative gas chromatographic separation of C2-C6 lower fatty acid homologues, methanol, and ethyl alcohol in aqueous microbial fermentation media. A hydrogen flame detector and a single-phase solid column packing, comprising beads of a polyaromatic resin (polystyrene cross-linked with divinyl benzene), were employed. Direct injections of 1 to 10 μliters of aqueous culture supernatant fluids were made. Quantitative recoveries of C2-C6 acids added to culture supernatant fluids were obtained. PMID:5645415

  16. Fouling propensity and separation efficiency of epoxidated polyethersulfone incorporated cellulose acetate ultrafiltration membrane in the retention of proteins

    NASA Astrophysics Data System (ADS)

    Jayalakshmi, A.; Rajesh, S.; Mohan, D.

    2012-10-01

    Epoxidated polyethersulfone (EPES) incorporated cellulose acetate (CA) ultrafiltration membranes were prepared by diffusion induced precipitation technique in the absence and presence of pore former polyethyleneglycol-600. Effect of blend ratio on the compatibility, thermal stability, mechanical strength, hydrophilicity, morphology, pure water flux, protein adsorption resistance, protein separation efficiency and fouling propensity of the CA/EPES blend membranes was evaluated. Addition of EPES results in the formation of thin separating layer and spongy sub layer in CA/EPES blend membranes. The efficiency of these membranes in the separation of commercially important proteins such as bovine serum albumin, egg albumin, pepsin and trypsin was studied and found to be enhanced as compared to CA membranes. The fouling-resistant capability of the membranes was studied by bovine serum albumin as the model foulant and flux recovery ratio of the membranes were calculated. Attempts have been made to correlate the changes in membrane morphology with pure water flux, hydraulic resistance, thermal and mechanical stability, separation efficiency and antifouling property of the CA/EPES membranes. The optimal combination of CA and EPES, thus allows the preparation of high performance UF membranes which are sufficiently dense to retain proteins and at the same time give economically viable fluxes.

  17. Polar Aprotic Modifiers for Chromatographic Separation and Back-Exchange Reduction for Protein Hydrogen/Deuterium Exchange Monitored by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Valeja, Santosh G.; Emmett, Mark R.; Marshall, Alan G.

    2012-04-01

    Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein-protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.

  18. Importance of MS selectivity and chromatographic separation in LC-MS/MS-based methods when investigating pharmaceutical metabolites in water. Dipyrone as a case of study.

    PubMed

    Ibáñez, M; Gracia-Lor, E; Sancho, J V; Hernández, F

    2012-08-01

    Pharmaceuticals are emerging contaminants of increasing concern because of their presence in the aquatic environment and potential to reach drinking-water sources. After human and/or veterinary consumption, pharmaceuticals can be excreted in unchanged form, as the parent compound, and/or as free or conjugated metabolites. Determination of most pharmaceuticals and metabolites in the environment is commonly made by liquid chromatography (LC) coupled to mass spectrometry (MS). LC coupled to tandem MS is the technique of choice nowadays in this field. The acquisition of two selected reaction monitoring (SRM) transitions together with the retention time is the most widely accepted criterion for a safe quantification and confirmation assay. However, scarce attention is normally paid to the selectivity of the selected transitions as well as to the chromatographic separation. In this work, the importance of full spectrum acquisition high-resolution MS data using a hybrid quadrupole time-of-flight analyser and/or a suitable chromatographic separation (to reduce the possibility of co-eluting interferences) is highlighted when investigating pharmaceutical metabolites that share common fragment ions. For this purpose, the analytical challenge associated to the determination of metabolites of the widely used analgesic dipyrone (also known as metamizol) in urban wastewater is discussed. Examples are given on the possibilities of reporting false positives of dypirone metabolites by LC-MS/MS under SRM mode due to a wrong assignment of identity of the compounds detected.

  19. Set-up of large laboratory-scale chromatographic separations of poly(ethylene glycol) derivatives of the growth hormone-releasing factor 1-29 analogue.

    PubMed

    Piquet, G; Gatti, M; Barbero, L; Traversa, S; Caccia, P; Esposito, P

    2002-01-25

    In this paper we report the scale-up of the purification of poly(ethylene glycol) (PEG) derivatives of the growth hormone-releasing factor 1-29, from laboratory scale (100 mg of bulk starting material) to larger scale (3 g of bulk), through the use of a cation-exchange TSK-SP-5PW chromatographic column. A one-step purification process capable of purifying large amounts of mono-PEGylated GRF species from the crude reaction mixture was developed. A simple, straightforward stepwise gradient elution separation was developed at laboratory scale and then scaled up with a larger column packed with a chromatographic resin with the same chemistry which maintained the laboratory-scale separation profile. Active material recovery and material purity remained constant through the scale-up from the 13-microm stationary phase to the 25-microm larger column. Overall, the gram GRF equivalent/batch process scale showed to be quite reproducible, and could be considered as a good platform for scale up to production scale.

  20. Polar Aprotic Modifiers for Chromatographic Separation and Back-Exchange Reduction for Protein Hydrogen/Deuterium Exchange Monitored by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    PubMed Central

    Valeja, Santosh G.; Emmett, Mark R.; Marshall, Alan G.

    2013-01-01

    Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein–protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent. PMID:22298288

  1. Separation of macromolecular proteins and removal of humic acid by cellulose acetate modified UF membranes.

    PubMed

    Kanagaraj, P; Nagendran, A; Rana, D; Matsuura, T

    2016-08-01

    Surface modifying macromolecules (SMMs) were synthesized with various polyurethane pre polymers end-capped with different groups and blended into the casting solution of cellulose acetate (CA) to prepare surface modified ultra-filtration (UF) membranes for water filtration applications. The surface modification of the CA membranes was confirmed by the FTIR and static contact angle (SCA) measurements. The membranes so prepared had the typical characteristics of UF membranes as confirmed by scanning electron microscopy (SEM). Membrane properties were studied in terms of membrane compaction, percentage water content (%WC), pure water flux (PWF), membrane hydraulic resistance (Rm), molecular weight cut-off (MWCO), average pore size and porosity. The result showed that PWF, %WC, MWCO and pore size increased whereas the Rm decreased by the addition of SMMs. The significant effect of SMMs on the fouling by humic acid (HA) was also observed. It was found that the cSMM-3 membrane, in which SMM was synthesized with diethylene glycol (DEG) and hydroxyl benzene sulfonate (HBS) was blended, had the highest flux recovery ratio FRR (84.6%), as well as the lowest irreversible fouling (15.4%), confirming their improved antifouling properties. Thus, the SMM modified CA membranes had proven, to play an important role in the water treatment by UF.

  2. On-line continuous sampling dynamic microwave-assisted extraction coupled with high performance liquid chromatographic separation for the determination of lignans in Wuweizi and naphthoquinones in Zicao.

    PubMed

    Gao, Shiqian; You, Jingyan; Wang, Ying; Zhang, Rui; Zhang, Hanqi

    2012-03-01

    The on-line continuous sampling dynamic microwave-assisted extraction (on-line CSDMAE) coupled with high-performance liquid chromatographic separation and determination of the lignans in Wuweizi and naphthoquinones in Zicao was developed. The extraction, separation and determination of target analytes were simultaneously carried out. The experimental parameters, including type of extraction solvent, microwave extraction power, solvent flow rate, amount of sample and particle size of the sample, were evaluated by the univariate method and orthogonal screening. The detection limits for schisandrin A, schisantherin A, deoxyschizandrin, shikonin and β,β'-dimethylacrylshikonin are 0.86, 0.90, 0.27, 0.42 and 0.92 μg mL⁻¹, respectively. Compared with the conventional extraction methods, such as off-line continuous microwave-assisted extraction, ultrasound-assisted extraction and Soxhlet extraction, the proposed method is quicker and more effective.

  3. Development of Low Cost Membranes (Ta, Nb & Cellulose Acetate) for H2/CO2 Separation in WGS Reactors

    SciTech Connect

    Seetala, Naidu; Siriwardane, Upali

    2011-12-15

    The main aim of this work is to synthesize low temperature bimetallic nanocatalysts for Water Gas Shift reaction (WGS) for hydrogen production from CO and steam mixture; and develop low-cost metal (Nb/Ta)/ceramic membranes for H2 separation and Cellulose Acetate membranes for CO2 separation. .

  4. Chromatographic separation of piracetam and its metabolite in a mixture of microsomal preparations, followed by an MS/MS analysis.

    PubMed

    Sahu, Kapendra; Siddiqui, Anees A; Shaharyar, Mohammad; Ahmad, Niyaz; Anwar, Mohammad; Ahmad, Farhan J

    2013-07-01

    A rapid bioanalytical method was evaluated for the simultaneous determination of piracetam and its metabolite (M1) in human microsomal preparations by fast ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS). In addition, a validated method of M1 in rat plasma was developed and successfully applied on pharmacokinetic studies. The present study was carried out to determine the metabolic pathways of piracetam for phase I metabolism and used cytochrome P450 isoforms responsible for the piracetam metabolism in human liver microsomes (HLMs). While additional potential metabolites of piracetam were suggested by computer-modeling. The resulting 2-(2-oxopyrrolidin-1-yl) acetic acid was the sole metabolite detected after the microsomal treatment. The amide hydrolysis mainly underwent to form a metabolite i.e., 2-(2-oxopyrrolidin-1-yl) acetic acid (M1).

  5. THORIUM OXALATE-URANYL ACETATE COUPLED PROCEDURE FOR THE SEPARATION OF RADIOACTIVE MATERIALS

    DOEpatents

    Gofman, J.W.

    1959-08-11

    The recovery of fission products from neutronirradiated uranium is described. The neutron-irradiated uranium is dissolved in acid and thorium oxalate is precipitated in ihe solution formed, whereby the fission products are carried on the thorium oxalate. The separated thorium oxalate precipitate is then dissolved in an aqueous oxalate solution and the solution formed is acidified, limiting ihe excess acidity to a maximum of 2 N, whereby thorium oxalate precipitates and carries lanthanum-rareearth- and alkaline-earth-metal fission products while the zirconium-fission-product remains in solution. This precipitate, too, is dissolved in an aqaeous oxalate solution at elevated temperature, and lanthanum-rare-earth ions are added to the solution whereby lanthanum-rare-earth oxalate forms and the lanthanum-rare-earth-type and alkalineearth-metal-type fission products are carried on the oxalate. The precipitate is separated from the solution.

  6. Improved separation of fluorogenic derivatized intact proteins with high resolution and efficiency using a reversed-phase liquid chromatographic system.

    PubMed

    Ichibangase, Tomoko; Nakata, Katsunori; Imai, Kazuhiro

    2014-06-01

    Although the efficient separation of intact protein mixtures is extremely difficult, reversed-phase chromatography is an important technique for performing quantitative, accurate and reproducible proteomics analyses. Here, we show that, despite the operating constraints of conventional high-performance liquid chromatography, such as column temperature, operating pressure and separation time, comprehensive separation of fluorogenic derivatized intact proteins could be achieved with high resolution and separation efficiency. First, amylin was chosen as a model peptide and used to estimate the separation efficiency with respect to column temperature and flow rate, as indicated by peak capacity. Then, an extract of human primary hepatocytes was used to model complex component mixtures and the separation conditions were optimized. The effects of mobile-phase pH, the separation time and the column length were also investigated. Consequently, more than 890 peaks could be separated efficiently in the extract, which is 1.5-fold greater than when using conventional conditions. Finally, it was demonstrated that both longer separation time and column length contributed greatly to the effective separation of the protein mixture. These results are expected to provide insights into the separation of intact proteins.

  7. Enantioselective nano liquid chromatographic separation of racemic pharmaceuticals: a facile one-pot in situ preparation of lipase-based polymer monoliths in capillary format.

    PubMed

    Ahmed, Marwa; Ghanem, Ashraf

    2014-11-01

    New affinity monolithic capillary columns of 150 µm internal diameter were prepared in situ fused glass capillary via either immobilization or encapsulation of Candida antarctica lipase B (CALB) on or within polymer monoliths, respectively. The immobilized lipase-based monoliths were prepared via copolymerization of 19.1% monomers (8.9% MMA and 10.2% GMA), 19.8% EDMA, and 61.1% porogens (54.2% formamide and 6.9% 1-propanol) w/w or 20% GMA, 20% EDMA, and 60% porogens (51.6% cyclohexanol and 8.4% 1-dodecanol) in the presence of AIBN (1%) as a radical initiator. This was followed by pumping a solution of lipase through the capillaries and rinsing with potassium phosphate buffer. On the other hand, the encapsulated lipase-based monoliths were prepared via copolymerization of 20% monomers (GMA), 20% EDMA, and 60% porogens (48% 1-propanol, 6% 1,4-butanediol) or 16.4% monomers (16% BuMA, 0.4% SPMA), 23.6% EDMA, and 60% porogens (36% 1-propanol, 18% 1,4-butanediol along with 6% lipase aqueous solution in potassium phosphate buffer. The prepared capillary columns were investigated for the enantioselective nano liquid chromatographic separation of a set of different classes of racemic pharmaceuticals, namely, α- and β-blockers, antiinflammatory drugs, antifungal drugs, dopamine antagonists, norepinephrine-dopamine reuptake inhibitors, catecholamines, sedative hypnotics, diuretics, antihistaminics, anticancer drugs, and antiarrhythmic drugs. Run-to-run repeatability was quite satisfactory. The encapsulated lipase-based capillary monolith showed better enantioselective separations of most of the investigated compounds. Baseline separation was achieved for alprenolol, atenolol, bromoglutithimide, carbuterol, chloropheneramine, cizolertine carbinol, 4-hydroxy-3-methoxymandelic acid, desmethylcizolertine, nomifensine, normetanephrine, and sulconazole under reversed phase chromatographic conditions. A speculation about the understanding of the chiral recognition mechanism of

  8. Optimization of liquid chromatographic method for the separation of nine hydrophilic and hydrophobic components in Salviae miltiorrhizae Radix et Rhizoma (Danshen) using microemulsion as eluent.

    PubMed

    Huang, Hongzhang; Xuan, Xueyi; Xu, Liyuan; Yang, Jianrui; Gao, Chongkai; Li, Ning

    2014-04-01

    In this study, we have proposed and developed a novel, environmental-friendly and simple method for separation of nine hydrophilic and hydrophobic components in Danshen using microemulsion liquid chromatography. The proposed method was optimized via the preliminary screening experiment and the experimental design. The following factors were investigated in preliminary screening experiment: pH of mobile phase, column type, the nature of surfactant, the nature of oil phase and additives. In order to simultaneously optimize resolution and analysis time, the chromatographic optimization function (COF) was adopted to evaluate chromatograms. The central composite design (CCD) was used to create the matrix of experiments for mapping the chromatographic response surface. Finally, the COF values were fitted into a second order polynomial model and the response surface methodology (RSM) was employed to find the optimal eluent constituents. The reliability of the established model was confirmed by the good agreement obtained between experimental data and predictive values. Based on the results from the preliminary screening experiment and the CCD optimization, the optimal mobile phase was identified as a solution consisting of 6.68% (w/w) polyoxyethylene lauryl ether (Brij35), 0.84% (w/w) cyclohexane, 6.92% (w/w) n-butanol, 85.56% (w/w) phosphate buffer (pH 6.60) and 8mM cetyltrimethyl ammonium bromide (CTAB).

  9. Synthesis and characterization of novel stationary phases for small scale liquid chromatographic separations of proteins and nanoparticles

    NASA Astrophysics Data System (ADS)

    Hutanu, Daniela

    The emerging field of nanotechnology strictly requires the micro-scaling of the available separation technology and the design of novel devices for separations of molecules of interest. The separation of proteins and nanoparticles is challenging due to their relatively large size, non-specific adherence to surfaces and instability in many solvents. This dissertation presents the synthesis and characterization of novel stationary phases for use in separations of proteins or nanoparticles in both capillary and microchip formats. In order to separate blood proteins with high specificity, a DNA aptamer selected for alpha-thrombin was employed as an affinity component of the stationary phases. Silica surfaces and organic monoliths were modified with the aptamer via an azlactone linkage and have demonstrated highly efficient separations of thrombin from a mixture in the microscale. The high efficiency of the protein separation (HETP = 276 mum, RS = 1.7) is comparable with macroscale results using antibodies as the affinity factor. Novel hybrid inorganic-organic polysilsesquioxane stationary phases were synthesized by way of surfactant templated polymerization of bridged alcoxy-silyl ethane monomers, in presence of sodium hydroxide. The novel materials were successful in size exclusion separation of polystyrene standards with molecular diameters of 0.3-2.4 nm. A hybrid inorganic-organic polysilsesquioxane sorbent also proved useful for small scale separations of triphenyl phosphine protected gold nanoparticles, based on a sorptive mechanism instead of a size exclusion mechanism. Polysilsesquioxanes were easily synthesized in-situ inside fused silica capillary columns and PMMA microchip channels in order to facilitate integration with a micro-reactor. The novel stationary phases proved efficient for separation of proteins and nanoparticles in the micro-scale format and can further be utilized for online purification and separation of these difficult compounds.

  10. High performance liquid chromatographic separations of gas oil samples and their hydrotreated products using commercial normal phases.

    PubMed

    Oro, Nicole E; Lucy, Charles A

    2011-10-28

    Three commercially available high performance liquid chromatography columns are used in normal phase or quasi-normal phase mode for the separation of gas oil samples. The columns are tested with 20 analytical standards to determine their suitability for separations of petroleum samples and their ability to separate the nitrogen group-types (pyrrole and pyridine) found in petroleum. The columns studied are polymeric hypercrosslinked polystyrene (HGN), a biphenyl phase, and a Chromegabond "DNAP" column from ES Industries. The HGN column separates gas oils based on both ring structure and heteroatom, while the biphenyl phase has low retention of most compounds studied in quasi-normal phase mode. The "DNAP" column is selective for nitrogen-containing compounds, separating them from PAHs as well as oxygen and sulphur compounds. Retention data of standards on all three columns is shown, along with chromatograms of gas oil samples on the HGN and "DNAP" columns.

  11. Fabrication of zeolitic imidazolate framework-8-methacrylate monolith composite capillary columns for fast gas chromatographic separation of small molecules.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah

    2015-08-07

    A composite zeolitic imidazolate framework-8 (ZIF-8) with a butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.) was fabricated to enhance the separation efficiency of methacrylate monoliths toward small molecules using conventional low-pressure gas chromatography in comparison with a neat butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.). The addition of 10mgmL(-1) ZIF-8 micro-particles increased the BET surface area of BuMA-co-EDMA by 3.4-fold. A fast separation of five linear alkanes in 36s with high resolution (Rs≥1.3) was performed using temperature program. Isothermal separation of the same sample also showed a high efficiency (3315platesm(-1) for octane) at 0.89min. Moreover, the column was able to separate skeletal isomers, such as iso-octane/octane and 2-methyl octane/nonane. In addition, an iso-butane/iso-butylene gas mixture was separated at ambient temperature. Comparison with an open tubular TR-5MS column (30m long×250μm i.d.) revealed the superiority of the composite column in separating the five-membered linear alkane mixture with 4-5 times increase in efficiency and a total separation time of 0.89min instead of 4.67min. A paint thinner sample was fully separated using the composite column in 2.43min with a good resolution (Rs≥0.89). The perfect combination between the polymeric monolith, with its high permeability, and ZIF-8, with its high surface area and flexible 0.34nm pore openings, led to the fast separation of small molecules with high efficiency and opened a new horizon in GC applications.

  12. Development of cellulose acetate propionate membrane for separation of ethanol and ethyl tert-butyl ether mixtures

    SciTech Connect

    Luo, G.S.; Niang, M.; Schaetzel, P.

    1997-04-01

    For pervaporation separation of ethanol and ethyl tert-butyl ether mixtures, a cellulose acetate propionate membrane was chosen as the experimental membrane because of its high selectivity and good mass fluxes. The properties of the membranes were evaluated by the pervaporation separation of mixtures of ethyl tert-butyl ether/ethanol and the sorption experiments. The experimental results showed that the selectivity and the permeates depend on the ethanol concentration in the feed and the experimental temperature. With increases of the ethanol weight fraction in the feed and the temperature, the total and partial mass fluxes increased. With respect to the temperature, ethanol mass flux obeys the Arrhenius equation. The selectivity of this membrane decreases as the temperature and the ethanol concentration in the feed increase. This membrane shows special characteristics at the azeotropic composition. In the vicinity of the azeotropic point, minimum values of ethanol concentration in the permeate and in sorption solution are obtained. The swelling ratios increase when temperature and the ethanol concentration in the feed are increasing. The ethanol concentration in the sorption solution is also influenced by the temperature and the mixture`s composition. When the temperature increases, the sorption selectivity of the membrane decreases.

  13. Gas chromatographic separation of stereoisomers of non-protein amino acids on modified γ-cyclodextrin stationary phase.

    PubMed

    Fox, Stefan; Strasdeit, Henry; Haasmann, Stephan; Brückner, Hans

    2015-09-11

    Stereoisomers (enantiomers and diastereoisomers) of synthetic, non-protein amino acids comprising α-, β-, and γ-amino acids, including α,α-dialkyl amino acids, were converted into the respective N-trifluoroacetyl-O-methyl esters and analyzed and resolved by gas chromatography (GC) on a commercial fused silica capillary column coated with the chiral stationary phase octakis(3-O-butyryl-2,6-di-O-pentyl)-γ-cyclodextrin. This column is marketed under the trade name Lipodex(®) E. Chromatograms, retention times, and a chart displaying the retention times of approximately 40 stereoisomers of amino acids are presented. With few exceptions, baseline or almost baseline resolution was achieved for enantiomers and diastereoisomers. The chromatographic method presented is considered to be highly suitable for the elucidation of the stereochemistry of non-protein amino acids, for example in natural products, and for evaluating the enantiopurity of genetically non-coded amino acids used for the synthesis and design of conformationally tailored peptides. The method is applicable to extraterrestrial materials or can be used in experimental work related to abiotic syntheses or enantioselective destruction and amplification of amino acids.

  14. Gas chromatographic separation of nitrogen, oxygen, argon, and carbon monoxide using custom-made porous polymers from high purity divinylbenzene

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.; Ohara, D.; Hollis, O. L.

    1984-01-01

    Existing porous polymers were surveyed for their ability to separate the subject gases. Certain products that showed more promise than others were synthesized and the existing synthetic procedures studied and modified to produce new polymers with enhanced ability to separate the subject gases. Evaluation of the porous polymers was carried out practically by gas chromatography at ambient temperature. The modified synthetic procedures were somewhat simpler than the originals. The new porous polymers made with high purity divinylbenzene enabled use of shorter columns to obtain the separations desired.

  15. Separation of short-chain fatty acids on a gas chromatographic column coated with oxidized lubricating oil.

    PubMed

    Moustafa, Nagy Emam

    2007-07-01

    The oxidized lubricating naphthenic base oil was used as a stationary phase for the separation of short-chain free fatty acids (SFFA) either as a pure sample or an aqueous solution containing 0.9-1.2 mg/L of each acid. It is found that the oil oxidation for 20 h improved the separation of SFFA in these two sample forms. This separation improvement represents not only the increase in retention volume intervals and peak symmetries in case of the pure sample but also in acid peak areas in case of the aqueous solution sample.

  16. Improving accuracy and precision of ice core δD(CH4) analyses using methane pre-pyrolysis and hydrogen post-pyrolysis trapping and subsequent chromatographic separation

    NASA Astrophysics Data System (ADS)

    Bock, M.; Schmitt, J.; Beck, J.; Schneider, R.; Fischer, H.

    2014-07-01

    Firn and polar ice cores offer the only direct palaeoatmospheric archive. Analyses of past greenhouse gas concentrations and their isotopic compositions in air bubbles in the ice can help to constrain changes in global biogeochemical cycles in the past. For the analysis of the hydrogen isotopic composition of methane (δD(CH4) or δ2H(CH4)) 0.5 to 1.5 kg of ice was hitherto used. Here we present a method to improve precision and reduce the sample amount for δD(CH4) measurements in (ice core) air. Pre-concentrated methane is focused in front of a high temperature oven (pre-pyrolysis trapping), and molecular hydrogen formed by pyrolysis is trapped afterwards (post-pyrolysis trapping), both on a carbon-PLOT capillary at -196 °C. Argon, oxygen, nitrogen, carbon monoxide, unpyrolysed methane and krypton are trapped together with H2 and must be separated using a second short, cooled chromatographic column to ensure accurate results. Pre- and post-pyrolysis trapping largely removes the isotopic fractionation induced during chromatographic separation and results in a narrow peak in the mass spectrometer. Air standards can be measured with a precision better than 1‰. For polar ice samples from glacial periods, we estimate a precision of 2.3‰ for 350 g of ice (or roughly 30 mL - at standard temperature and pressure (STP) - of air) with 350 ppb of methane. This corresponds to recent tropospheric air samples (about 1900 ppb CH4) of about 6 mL (STP) or about 500 pmol of pure CH4.

  17. Improving accuracy and precision of ice core δD (CH4) analyses using methane pre- and hydrogen post-pyrolysis trapping and subsequent chromatographic separation

    NASA Astrophysics Data System (ADS)

    Bock, M.; Schmitt, J.; Beck, J.; Schneider, R.; Fischer, H.

    2013-12-01

    Firn and polar ice cores offer the only direct paleoatmospheric archive. Analyses of past greenhouse gas concentrations and their isotopic compositions in air bubbles in the ice can help to constrain changes in global biogeochemical cycles in the past. For the analysis of the hydrogen isotopic composition of methane (δD (CH4)) 0.5 to 1.5 kg of ice was previously necessary to achieve the required precision. Here we present a method to improve precision and reduce the sample amount for δD (CH4) measurements on (ice core) air. Pre-concentrated methane is focused before a high temperature oven (pre pyrolysis trapping), and molecular hydrogen formed by pyrolysis is trapped afterwards (post pyrolysis trapping), both on a carbon-PLOT capillary at -196 °C. A small amount of methane and krypton are trapped together with H2 and must be separated using a short second chromatographic column to ensure accurate results. Pre and post pyrolysis trapping largely removes the isotopic fractionation induced during chromatographic separation and results in a narrow peak in the mass spectrometer. Air standards can be measured with a precision better than 1‰. For polar ice samples from glacial periods we estimate a precision of 2.2‰ for 350 g of ice (or roughly 30 mL (at standard temperature and pressure (STP)) of air) with 350 ppb of methane. This corresponds to recent tropospheric air samples (about 1900 ppb CH4) of about 6 mL (STP) or about 500 pmol of pure CH4.

  18. Performance of short-chain alcohols versus acetonitrile in the surfactant-mediated reversed-phase liquid chromatographic separation of β-blockers.

    PubMed

    Ruiz-Ángel, M J; Torres-Lapasió, J R; Carda-Broch, S; García-Álvarez-Coque, M C

    2010-11-05

    Organic solvents are traditionally added to micellar mobile phases to achieve adequate retention times and peak profiles, in a chromatographic mode which has been called micellar liquid chromatography (MLC). The organic solvent content is limited to preserve the formation of micelles. However, at increasing organic solvent contents, the transition to a situation where micelles do not exist is gradual. Also, there is no reason to neglect the potentiality of mobile phases containing only surfactant monomers instead of micelles (high submicellar chromatography, HSC). This is demonstrated here for the analysis of β-blockers. The performance of four organic solvents (methanol, ethanol, 1-propanol, and acetonitrile) was compared in mobile phases containing the anionic surfactant sodium dodecyl sulphate in the MLC and HSC modes. The association of the organic solvent molecules with micelles gives rise to a significant loss in the elution strength of the organic solvent; whereas upon disruption of micelles, it tends to that observed in the hydro-organic mode. The elution behaviour of the β-blockers was modelled to predict the retention times. This allowed the detailed exploration of the selectivity and resolution of the chromatographic systems in relatively wide ranges of concentration of surfactant and organic solvent. The best performance in terms of resolution and analysis time was achieved using HSC with acetonitrile, being able to base-line resolve a mixture of eight β-blockers. Ethanol also provided a good separation performance, significantly improved with respect to methanol and 1-propanol. In contrast, the hydro-organic mode using acetonitrile or any of the short-chain alcohols could not succeed with the separation of the β-blockers, owing to the poorer selectivity and wider peaks.

  19. Isolation of flavonoids from Aleurites moluccana using chitosan modified with benzaldehyde (CH-Bz) as chromatographic support.

    PubMed

    Girardi, L G J; Morsch, M; Cechinel-Filho, V; Meyre-Silva, C; Rodrigues, C A

    2003-09-01

    This paper describes the preparation, characterization and use of a derivative of chitosan as a chromatographic sorbent. Chitosan modified with benzenic ring (CH-Bz) was used to separate two flavonoids, swertisin and 2"-O-rhamnosylswertisin, from ethyl acetate fraction of Aleurites moluccana. The results showed that CH-Bz can be used as a sorbent for the separation of flavonoid compounds. The studies showed that CH-Bz in column chromatography produces goods results, separation of the flavonoid compounds.

  20. Chromatographic Separation of Cd from Plants via Anion-Exchange Resin for an Isotope Determination by Multiple Collector ICP-MS.

    PubMed

    Wei, Rongfei; Guo, Qingjun; Wen, Hanjie; Peters, Marc; Yang, Junxing; Tian, Liyan; Han, Xiaokun

    2017-01-01

    In this study, key factors affecting the chromatographic separation of Cd from plants, such as the resin column, digestion and purification procedures, were experimentally investigated. A technique for separating Cd from plant samples based on single ion-exchange chromatography has been developed, which is suitable for the high-precision analysis of Cd isotopes by multiple-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). The robustness of the technique was assessed by replicate analyses of Cd standard solutions and plant samples. The Cd yields of the whole separation process were higher than 95%, and the (114/110)Cd values of three Cd second standard solutions (Münster Cd, Spex Cd, Spex-1 Cd solutions) relative to the NIST SRM 3108 were measured accurately, which enabled the comparisons of Cd isotope results obtained in other laboratories. Hence, stable Cd isotope analyses represent a powerful tool for fingerprinting specific Cd sources and/or examining biogeochemical reactions in ecological and environmental systems.

  1. [Applicability of cellulose acetate electrophoresis of globin chains to thalassemia screening].

    PubMed

    Masala, B; Demuro, P; Dore, F; Formato, M; Longinotti, M; Tidore, M

    1981-07-15

    We considered the possible application of globin chain separation on cellulose acetate strips electrophoresis to thalassemia screening. The method shows good accuracy and reproducibility when compared with the chromatographic method on CM-cellulose. The electrophoretic method could be recommended as the simplest test of hemoglobin biosynthesis in countries where high incidence of thalassemic syndromes occurs.

  2. Retention behavior of phenols, anilines, and alkylbenzenes in liquid chromatographic separations using subcritical water as the mobile phase.

    PubMed

    Yang, Y; Jones, A D; Eaton, C D

    1999-09-01

    The unique characteristic of subcritical water is its widely tunable physical properties. For example, the polarity (measured by dielectric constant) of water is significantly decreased by raising water temperature. At temperatures of 200-250 °C (under moderate pressure to keep water in the liquid state), the polarity of pure water is similar to that of pure methanol or acetonitrile at ambient conditions. Therefore, pure subcritical water may be able to serve as the mobile phase for reversed-phase separations. To investigate the retention behavior in subcritical water separation, the retention factors of BTEX (benzene, toluene, ethylbenzene, and m-xylene), phenol, aniline, and their derivatives have been determined using subcritical water, methanol/water, and acetonitrile/water systems. Subcritical water separations were also performed using alumina, silica-bonded C18, and poly(styrene-divinylbenzene) columns to study the influence of the stationary phase on analyte retention under subcritical water conditions.

  3. Gas chromatographic separation of hydrogen isotopes on columns packed with alumina, modified alumina and sol-gel alumina.

    PubMed

    Naik, Y P; Gupta, N K; Pillai, K T; Rao, G A Rama; Venugopal, V

    2012-01-06

    The stationary phase of alumina adsorbents, prepared by different chemical processes, was used to study the separation behaviour of hydrogen isotopes. Three types of alumina, obtained by conventional hydroxide route alumina coated with silicon oxide and alumina prepared by internal gelation process (IGP), were used as packing material to study the separation of HT and T(2) in a mixture at various temperatures. The conventional alumina and silicon oxide coated alumina resolved HT and T(2) at 77K temperature with different retention times. The retention times on SiO(2) coated columns were found to be higher than those of other adsorbents. However, the column filled with IGP alumina was found to be ideal for the separation of HT and T(2) at 240 K. The peaks were well resolved in less than 5 min on this column.

  4. Gradient HPLC separation of dehydroepiandrosterone (DHEA) from its metabolites and biological congeners: role of tetrahydrofuran in the chromatographic mechanism.

    PubMed

    Gergely, András; Horváth, Péter; Szász, György; Veress, Gábor

    2009-08-01

    A three-step gradient reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the separation of dehydroepiandrosterone (DHEA), its sulfate ester (DHEA-S), its three C7-oxidized metabolites (7alphaOH-DHEA, 7betaOH-DHEA, 7-keto-DHEA), and its biosynthetic congeners (androstenedione, testosterone, estradiol, pregnenolone). This new method allows the quantitative characterization of DHEA metabolism and biosynthetic transformation under given physiological, pathological, or therapeutically influenced circumstances. Tetrahydrofuran probably acts as a proton acceptor coadsorbent, while isopropanol behaves as a proton donor during the separation of testosterone, estradiol, and the stereoisomers of 7-OH-DHEA.

  5. An analytical method with a single extraction procedure and two separate high performance liquid chromatographic systems for the determination of artesunate, dihydroartemisinin and mefloquine in human plasma for application in clinical pharmacological studies of the drug combination.

    PubMed

    Lai, Choon-Sheen; Nair, N K; Mansor, S M; Olliaro, P L; Navaratnam, V

    2007-10-01

    The combination of two sensitive, selective and reproducible reversed phase liquid chromatographic (RP-HPLC) methods was developed for the determination of artesunate (AS), its active metabolite dihydroartemisinin (DHA) and mefloquine (MQ) in human plasma. Solid phase extraction (SPE) of the plasma samples was carried out on Supelclean LC-18 extraction cartridges. Chromatographic separation of AS, DHA and the internal standard, artemisinin (QHS) was obtained on a Hypersil C4 column with mobile phase consisting of acetonitrile-0.05 M acetic acid adjusted to pH 5.2 with 1.0M NaOH (42:58, v/v) at the flow rate of 1.50 ml/min. The analytes were detected using an electrochemical detector operating in the reductive mode. Chromatography of MQ and the internal standard, chlorpromazine hydrochloride (CPM) was carried out on an Inertsil C8-3 column using methanol-acetonitrile-0.05 M potassium dihydrogen phosphate adjusted to pH 3.9 with 0.5% orthophosphoric acid (50:8:42, v/v/v) at a flow rate of 1.00 ml/min with ultraviolet detection at 284 nm. The mean recoveries of AS and DHA over a concentration range of 30-750 ng/0.5 ml plasma and MQ over a concentration of 75-1500 ng/0.5 ml plasma were above 80% and the accuracy ranged from 91.1 to 103.5%. The within-day coefficients of variation were 1.0-1.4% for AS, 0.4-3.4% for DHA and 0.7-1.5% for MQ. The day-to-day coefficients of variation were 1.3-7.6%, 1.8-7.8% and 2.0-3.4%, respectively. Both the lower limit of quantifications for AS and DHA were at 10 ng/0.5 ml and the lower limit of quantification for MQ was at 25 ng/0.5 ml. The limit of detections were 4 ng/0.5 ml for AS and DHA and 15 ng/0.5 ml for MQ. The method was found to be suitable for use in clinical pharmacological studies.

  6. Chromatographic separation of certain metal ions using a bifunctional quaternary ammonium-sulfonate mixed bed ion-exchanger.

    PubMed

    Lasheen, Y F; Seliman, A F; Abdel-Rassoul, A A

    2006-12-15

    The separation behaviour of Pb(2+), Cu(2+), Cd(2+), Co(2+), Zn(2+) and Ni(2+) on bifunctional quaternary ammonium-sulfonate mixed ion-exchangers (Dionex, IonPac CS5 and CG5) was studied using different eluents including solutions of oxalic acid, potassium oxalate, sodium oxalate and ammonium oxalate. Separated metal ions were followed by using 4-(2-pyridylazo) resorcinol (PAR) as post-colouring complex. The retention factors of different ions proved to be dependent on the pH, concentration, nature of each complexing agent, and to less extent on eluent flow rate. The retention behaviour and separation mechanism of complexed metal analytes are discussed in the light of the stability of metal complexes and the ligand complexing ability of used eluent. Comparison between various mobile phases is evaluated, and both sodium and potassium oxalate can be used successfully for simultaneous separation of studied metals with good resolution within short elution periods. The method can be used in different applications including analysis of bottled water from different resources.

  7. Determination of uranium and thorium in complex samples using chromatographic separation, ICP-MS and spectrophotometric detection.

    PubMed

    Rozmarić, Martina; Ivsić, Astrid Gojmerac; Grahek, Zeljko

    2009-11-15

    The paper describes a research of possible application of UTEVA and TRU resins and anion exchanger AMBERLITE CG-400 in nitrate form for the isolation of uranium and thorium from natural samples. The results of determination of distribution coefficient have shown that uranium and thorium bind on TRU and UTEVA resins from the solutions of nitric and hydrochloric acids, and binding strength increases proportionally to increase the concentration of acids. Uranium and thorium bind rather strongly to TRU resin from the nitric acid in concentration ranging from 0.5 to 5 mol L(-1), while large quantities of other ions present in the sample do not influence on the binding strength. Due to the difference in binding strength in HCl and HNO(3) respectively, uranium and thorium can be easily separated from each other on the columns filled with TRU resin. Furthermore, thorium binds to anion exchanger in nitrate form from alcohol solutions of nitric acid very strongly, while uranium does not, so they can be easily separated. Based on these results, we have created the procedures of preconcentration and separation of uranium and thorium from the soil, drinking water and seawater samples by using TRU and UTEVA resins and strong base anion exchangers in nitrate form. In one of the procedures, uranium and thorium bind directly from the samples of drinking water and seawater on the column filled with TRU resin from 0.5 mol L(-1) HNO(3) in a water sample. After binding, thorium is separated from uranium with 0.5 mol L(-1) HCl, and uranium is eluted with deionised water. By applying the described procedure, it is possible to achieve the concentration factor of over 1000 for the column filled with 1g of resin and splashed with 2L of the sample. Spectrophotometric determination with Arsenazo III, with this concentration factor results in detection limits below 1 microg L(-1) for uranium and thorium. In the second procedure, uranium and thorium are isolated from the soil samples with TRU

  8. Development and validation of a new stability indicating reversed phase liquid chromatographic method for the determination of prednisolone acetate and impurities in an ophthalmic suspension.

    PubMed

    Marley, Adrian; Stalcup, Apryll M; Connolly, Damian

    2015-01-01

    A new stability indicating reversed phase high performance liquid chromatography (RP-HPLC) method was developed and validated under current International Conference of Harmonisation (ICH) guidance for the determination of prednisolone acetate (PAC) and impurities in an ophthalmic suspension. The developed method is presented as an alternative to a modified version of the current RP-HPLC method described in the USP monograph for the assay of PAC in an ophthalmic suspension. Along with the assay of PAC, the new method is also capable of identifying and quantifying eight selected PAC impurities and degradation products in an ophthalmic suspension. Using an Agilent Poroshell 120 EC-C18 100 mm × 4.6mm (dp: 2.7 μm) column set to 60°C with step gradient elution generated using mobile phase A: acetonitrile/water (10:90) (v/v) and mobile phase B: acetonitrile delivered at 1.2 mL min(-1), all peaks of interest are eluted in 33 min with resolution of 1.5 between the critical pairs. The developed method was validated for PAC and impurities to ICH recommendations for accuracy, linearity, precision (repeatability), limit of detection, limit of quantitation, robustness and specificity.

  9. Modification of the murakami retention model in reversed-phase high-performance liquid chromatography for micellar chromatographic separations

    NASA Astrophysics Data System (ADS)

    Loginova, L. P.; Boichenko, A. P.; Kulikov, A. Yu.

    2008-09-01

    A retention model for micellar liquid chromatography was tested based on the data of separation of three benzodiazepins and six β-blockers. The model was obtained by analyzing changes in the microenvironment of a sorbate in transferring from the mobile to stationary phase. It can be used to describe the retention of benzodiazepins, which are neutral under the separation conditions, and the positively charged β-blockers. The calculated model coefficients are indicative of an increase in the number of 1-pentanol molecules and sodium dodecyl sulfate monomers in the microenvironment of the sorbates in transferring from the mobile to stationary phase. The solvation of the positive β-blockers by anionic surfactant monomers was higher than that of neutral benzodiazepins.

  10. Effects of ammonioalkyl sulfonate internal salts on electrokinetic micropump performance and reversed-phase high-performance liquid chromatographic separations.

    PubMed

    Reichmuth, David S; Kirby, Brian J

    2003-09-26

    Ammonioalkyl sulfonate internal salts are explored owing to their potential for improving electrokinetic pumps used to perform miniaturized HPLC separations. The internal salts investigated can be added at high molarity since they are net-neutral, and furthermore show potential for increasing electroosmotic pumping owing to their large positive dielectric increment. Streaming potential measurements of buffered aqueous systems with varying concentrations of ammonioalkyl sulfonate internal salts have been used to measure these dielectric increments, which increase with the length of the alkyl linker. Due to their positive dielectric increments and their decremental effect on solution conductivity, all of the measured species are predicted to improve the pressure generation (up to 85%) and efficiency performance (up to 140%) of electrokinetic pumps when added at 1 M concentration. RP-HPLC separations with an ammonioalkyl sulfonate (TMAPS) have been performed and indicate that separation performance is essentially unaffected by these species. These results indicate the potential for a variety of ammonioalkyl sulfonates to be used to improve electrokinetic pump performance for miniaturized HPLC.

  11. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    PubMed

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous.

  12. Chromatographic separation and detection of contaminants from whole milk powder using a chitosan-modified silver nanoparticles surface-enhanced Raman scattering device.

    PubMed

    Li, Dan; Lv, Di Y; Zhu, Qing X; Li, Hao; Chen, Hui; Wu, Mian M; Chai, Yi F; Lu, Feng

    2017-06-01

    Methods for the on-site analysis of food contaminants are in high demand. Although portable Raman spectroscopy is commonly used to test food on-site, it can be challenge to achieve this goal with rapid detection and inexpensive substrate. In this study, we detected trace food contaminants in samples of whole milk powder using the methods that combined chromatography with surface-enhanced Raman scattering detection (SERS). We developed a simple and efficient technique to fabricate the paper with chitosan-modified silver nanoparticles as a SERS-active substrate. The soaking time of paper and the concentration of chitosan solution were optimized for chromatographic separation and SERS detection. We then studied the separation properties for real applications including complex sample matrices, and detected melamine at 1mg/L, dicyandiamide at 100mg/L and sodium sulfocyanate at 10mg/L in whole milk powder. As such, our methods have great potential for field-based detection of milk contaminants.

  13. Reversed-phase ion-pair liquid chromatographic method for determination of reaction equilibria involving ionic species: exemplification of the method using ligand substitution reactions of ethylenediaminetetraacetatochromium(III) ion with acetate and phosphate ions.

    PubMed

    Sato, Emiko; Miya, Seiko; Saitoh, Kazunori; Saito, Shingo; Shibukawa, Masami

    2011-02-18

    A reversed-phase ion-pair liquid chromatographic method is presented for the determination of reaction equilibria involving ionic species of the same charge sign as reactant and product compounds. It has been demonstrated that ion-exchange chromatography or reversed-phase ion-pair chromatography is a useful tool for the determination of equilibrium constants of chemical reactions involving ionic species such as metal complexation reactions. Previous work with these methods has been based on the assumption that the limiting retention factors of the reactant and product species are constant independent of concentration of the chemical species (X) in the mobile phase, which reacts with the analyte compound. However, when all the reactant and product species are ions of the same charge sign as that of the species X, it is virtually impossible to apply these methods to the equilibrium constant determination because the retention factors of both the reactant and product species may depend on the concentration of X. In this study, an alternative approach was developed that estimates the limiting retention factors of ionic species from the dependence of the retention factor on the ionic strength of the mobile phase. Ligand substitution reactions of ethylenediaminetetraacetatochromium(III) ion with acetate and phosphate ions were used as model reactions to test this method. The equilibrium constants determined by this method are in good agreement with those obtained by a UV-visible spectrophotometric method.

  14. High-pressure liquid chromatographic separation of the naturally occurring toxicants myristicin, related aromatic ethers and falcarinol.

    PubMed

    Wulf, L W; Nagel, C W; Branen, A L

    1978-11-21

    The naturally occurring toxicants myristicin, twelve related aromatic ethers and the toxic acetylenic alcohol, falcarinol, were separated from one another by high-pressure liquid chromatography (HPLC). The technique employed a microparticulate nitrile phase column and used heptane and tetrahydrofuran as the eluting solvents. Preparative HPLC with 5-micrometer silica allowed isolation of gram quantities of parsleyapiole and dillapiole from extracts of plain parsley seeds and dill seeds, respectively. Commercially available myristicin as well as other aromatic ethers were also purified in gram quantities with the preparative column.

  15. Chromatographic Degradation of Phloridzin

    PubMed Central

    Grochowska, Maria J.

    1966-01-01

    Phloridzin, the main phenolic glucoside in apple leaves, has been found to undergo transformation during chromatography. When chromatographed repeatedly in ammoniacal solvents, at least 2 new derivatives appeared. One of these was identified as phloretic acid. When bioassayed in the presence of indole-3-acetic acid this substance behaved as though it promoted the destruction of the auxin. Comparative bioassay with naphthaleneacetic acid suggested that phloretic acid acts on indoleacetic acid destruction via stimulation of indoleacetic acid oxidase. However, at low concentration and in presence of a small amount of phloridzin it also showed a synergistic effect with indoleacetic acid. A substance with the same characteristics was obtained directly from apple leaves, which are known to contain phloridzin when the extracts were chromatographed only once in the same (alkaline) solvent. While not completely confirmed, this suggests that phloretic acid is normally present in apple leaves, where it may affect growth there by promoting indoleacetic acid oxidation. Images PMID:16656273

  16. Incorporation of carbon nanotubes in a silica HPLC column to enhance the chromatographic separation of peptides: theoretical and practical aspects.

    PubMed

    André, Claire; Aljhani, Rania; Gharbi, Tijani; Guillaume, Yves C

    2011-06-01

    The retention mechanism of a series of peptides on a single-wall carbon nanotube (SWCNT) stationary phase inside an HPLC column was investigated over a wide range of mobile phase compositions. While the similar size C18 column exhibited an efficiency of 11.5 μm, the SWCNT column increased the efficiency, i.e. 7.10 μm at a flow rate of 0.8 mL/min, and significantly affected the separation quality of the peptides. The values of enthalpy (ΔH) and entropy (ΔS(*)) of transfer of the peptides from the mobile to the SWCNT stationary phase were determined. The method studied each factor, i.e. ACN fraction x in the ACN/water mixture and column temperature. The changes in retention factor, ΔH and ΔS(*) as a function of the ACN fraction in the mobile phase were examined. These variations are explained using the organization of ACN in clusters in the ACN/water mixture and on the steric and electronic forces implied in the retention process. The information obtained in this work makes this SWCNT stationary phase useful for peptide research and demonstrated the role of ACN to improve the separation quality.

  17. Combined cation-exchange and extraction chromatographic method of pre-concentration and concomitant separation of Cu(II) with high molecular mass liquid cation exchanger after its online detection.

    PubMed

    Mandal, B; Roy, U S; Datta, D; Ghosh, N

    2011-08-19

    A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1M acetate buffer at the range of pH 4.0-5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (K(ex)) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol⁻¹) and ΔS (0.1916 kJ mol⁻¹) and negative value of ΔG (-49.16 kJ mol⁻¹) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants K(desorption)¹(1.4 × 10⁻²) and K(desorption)²(9.8 × 10⁻²) were determined. The effect of pH on R(f) values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested.

  18. Design of a coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with polar organic-aqueous two-phase solvent systems.

    PubMed

    Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-05-01

    A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1=ω2+ω3. This relation enabled to lay out the flow tube without twisting by the simultaneous rotation of three axes. The flow tube was introduced from the bottom side of the apparatus into the sun axis of the first rotary frame reaching the upper side of the planet axis and connected to the column in the satellite axis. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3:2:5, v/v) for lower phase mobile and (1:4:5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) - CCW (ω2) - CCW (ω3) by the flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) - CW (ω2) - CW (ω3) by the flow tube distribution. A series of experiments on peak resolution and stationary phase retention revealed that better partition efficiencies were obtained at the flow rate of 0.5 mL/min (column 1) and 0.8 mL/min (column 2) for lower phase mobile and 0.2 mL/min (column 1) and 0.4 mL/min (column 2) for upper phase

  19. Preparation of a New Chiral Stationary Phase Based on Macrocyclic Amide Chiral Selector for the Liquid Chromatographic Chiral Separations.

    PubMed

    Sung, Ji Yeong; Choi, Seung Hyuck; Hyun, Myung Ho

    2016-03-01

    A new chiral stationary phase (CSP) based on macrocyclic amide receptor was prepared starting from (1R,2R)-1,2-diphenylethylenediamine. The new CSP was successfully applied to the resolution of various N-(substituted benzoyl)-α-amino amides with reasonably good separation factors and resolutions (α = 1.75 ~ 2.97 and RS  = 2.89 ~ 6.82 for 16 analytes). The new CSP was also applied to the resolution of 3-substituted 1,4-benzodiazepin-2-ones and some diuretic chiral drugs including bendroflumethiazide and methylchlothiazide and metolazone. The resolution results for 3-substituted 1,4-benzodiazepin-2-ones and some diuretic chiral drugs were also reasonably good.

  20. Simultaneous separation and sensitive detection of naringin and naringenin in nanoparticles by chromatographic method indicating stability and photodegradation kinetics.

    PubMed

    Cordenonsi, Leticia Malgarim; Bromberger, Nathany Genro; Raffin, Renata Platcheck; Scherman, Elfrides Eva

    2016-02-01

    A simple, sensitive, precise and linear method by liquid chromatography was established for simultaneous determination and quantification of naringin and naringenin in polymeric nanoparticles. The method results in excellent separation in <11 min and with a peak purity of both flavonoids. The analyses were performed using a C18 column (4.6 × 150 mm, 5 µm), at a 1 mL/min flow rate. The mobile phase consisted of a gradient of acetonitrile-water (pH 4.0; v/v) at a temperature of 25°C. The nanoparticles were prepared according to the method of interfacial deposition of a pre-formed polymer. The method were validated in compliance with guidelines, and was found to be linear in the 1-40 µg/mL concentration range for both naringin and naringenin (r > 0.99). Repeatability was determined at three concentration levels, obtaining an RSD (%) <0.9%, and the accuracy of the method was >98%. The photodegradation kinetics was determined for naringin; the coefficient that best represents degradation was of first order and naringenin presented a zero-order kinetics. To our knowledge, a rapid and sensitive method for naringin and naringenin in polymeric nanoparticles has not been published elsewhere and this method is applicable to simultaneous evaluation of flavonoids.

  1. Determination of methyl mercury by aqueous phase Eehylation, followed by gas chromatographic separation with cold vapor atomic fluorescence detection

    USGS Publications Warehouse

    De Wild, John F.; Olsen, Mark L.; Olund, Shane D.

    2002-01-01

    A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations

  2. Capillary gas chromatographic separation of organic bases using a pH-adjusted basic water stationary phase.

    PubMed

    Darko, Ernest; Thurbide, Kevin B

    2016-09-23

    The use of a pH-adjusted water stationary phase for analyzing organic bases in capillary gas chromatography (GC) is demonstrated. Through modifying the phase to typical values near pH 11.5, it is found that various organic bases are readily eluted and separated. Conversely, at the normal pH 7 operating level, they are not. Sodium hydroxide is found to be a much more stable base than ammonium hydroxide for altering the pH due to the higher volatility and evaporation of the latter. In the basic condition, such analytes are not ionized and are observed to produce good peak shapes even for injected masses down to about 20ng. By comparison, analyses on a conventional non-polar capillary GC column yield more peak tailing and only analyte masses of 1μg or higher are normally observed. Through carefully altering the pH, it is also found that the selectivity between analytes can be potentially further enhanced if their respective pKa values differ sufficiently. The analysis of different pharmaceutical and petroleum samples containing organic bases is demonstrated. Results indicate that this approach can potentially offer unique and beneficial selectivity in such analyses.

  3. Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

    USGS Publications Warehouse

    Simon, N.S.

    1997-01-01

    Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

  4. Comprehensive ultra-performance liquid chromatographic separation and mass spectrometric analysis of eicosanoid metabolites in human samples.

    PubMed

    Wang, Yan; Armando, Aaron M; Quehenberger, Oswald; Yan, Chao; Dennis, Edward A

    2014-09-12

    Over the past decade, the number of known eicosanoids has expanded immensely and we have now developed an ultra-performance liquid chromatography-electrospray ionization triple quadrupole mass spectrometric (UPLC-QTRAP/MS/MS) method to monitor and quantify numerous eicosanoids. The UPLC-QTRAP/MS/MS approach utilizes scheduled multiple reaction monitoring (MRM) to optimize sensitivity, number of metabolites that can be analyzed and the time requirement of the analysis. A total of 184 eicosanoids including 26 deuterated internal standards can be separated and monitored in a single 5min UPLC run. To demonstrate a practical application, human plasma samples were analyzed following solid-phase extraction (SPE) and the recovery rate and matrix effects were determined for the 26 deuterated internal standards added to the plasma. The method was validated and shown to be sensitive with the limit of quantitation at pg levels for most compounds, accurate with recovery rates of 70-120%, and precise with a CV<30 for all compounds. Also, the method showed a linear response over a range spanning several orders of magnitude. In a QC human plasma sample, we identified and rigorously quantified over 120 eicosanoids.

  5. High-performance liquid chromatographic determination of beta-alanine, beta-aminoisobutyric acid and gamma-aminobutyric acid in tissue extracts and urine of normal and (aminooxy)acetate-treated rats.

    PubMed

    Abe, T; Kurozumi, Y; Yao, W B; Ubuka, T

    1998-08-07

    A method is described for the simultaneous determination of beta-alanine, beta-aminoisobutyric acid and gamma-aminobutyric acid in biological materials. Amino acids including these beta- and gamma-amino acids were derivatized with 4-dimethylaminoazobenzene-4'-sulfonyl (dabsyl) chloride and dabsyl amino acids formed were separated by reversed-phase high-performance liquid chromatography. Dabsyl derivatives of these beta- and gamma-amino acids were well separated from other dabsyl-amino acids. The method was applied to the determination of these beta- and gamma-amino acids in trichloroacetic acid extracts of various tissues and to the urine of normal rats and those injected with (aminooxy)acetate (AOA). AOA injection (15 mg per kg of body mass) produced remarkable increase in beta-alanine contents in liver, kidney and urine (10.2, 4.6 and 25.7 times, respectively).

  6. O-Allylation of phenols with allylic acetates in aqueous media using a magnetically separable catalytic system

    EPA Science Inventory

    Allylic ethers were synthesized in water using magnetically recoverable heterogeneous Pd catalyst via O-allylation of phenols with allylic acetates under ambient conditions. Aqueous reaction medium, easy recovery of the catalyst using an external magnet, efficient recycling, and ...

  7. A novel approach for quantitation of nonderivatized sialic acid in protein therapeutics using hydrophilic interaction chromatographic separation and nano quantity analyte detection.

    PubMed

    Chemmalil, Letha; Suravajjala, Sreekanth; See, Kate; Jordan, Eric; Furtado, Marsha; Sun, Chong; Hosselet, Stephen

    2015-01-01

    This paper describes a novel approach for the quantitation of nonderivatized sialic acid in glycoproteins, separated by hydrophilic interaction chromatography, and detection by Nano Quantity Analyte Detector (NQAD). The detection technique of NQAD is based on measuring change in the size of dry aerosol and converting the particle count rate into chromatographic output signal. NQAD detector is suitable for the detection of sialic acid, which lacks sufficiently active chromophore or fluorophore. The water condensation particle counting technology allows the analyte to be enlarged using water vapor to provide highest sensitivity. Derivatization-free analysis of glycoproteins using HPLC/NQAD method with PolyGLYCOPLEX™ amide column is well correlated with HPLC method with precolumn derivatization using 1, 2-diamino-4, 5-methylenedioxybenzene (DMB) as well as the Dionex-based high-pH anion-exchange chromatography (or ion chromatography) with pulsed amperometric detection (HPAEC-PAD). With the elimination of derivatization step, HPLC/NQAD method is more efficient than HPLC/DMB method. HPLC/NQAD method is more reproducible than HPAEC-PAD method as HPAEC-PAD method suffers high variability because of electrode fouling during analysis. Overall, HPLC/NQAD method offers broad linear dynamic range as well as excellent precision, accuracy, repeatability, reliability, and ease of use, with acceptable comparability to the commonly used HPAEC-PAD and HPLC/DMB methods.

  8. Versatile gas/particle ion chromatograph.

    PubMed

    Ullah, S M Rahmat; Takeuchi, Masaki; Dasgupta, Purnendu K

    2006-02-01

    A new, compact gas/particle ion chromatograph has been developed for measuring ionic constituents in PM2.5 (particulate matter of aerodynamic diameter < or = 2.5 microm) and water-soluble ionogenic gases. The instrument has separate sampling channels for gases and particles. In one, a membrane denuder collects soluble gases for preconcentration and analysis. In the other, a cyclone removes larger particles, a membrane denuder removes soluble gases, and a continuously wetted hydrophilic filter collects particles. A single, multiport, syringe pump handles liquid transport, and one conductivity detector measures anions and ammonium for both channels. Electrodialytically generated gradient hydroxide eluent permits 20 min chromatographic runs. Gas/particle samples are each collected for 40 min, butthe sampling intervals are staggered by 20 min. Liquid samples from the gas denuder and particle collector are aspirated and preconcentrated on sequential cation and anion concentrators and transferred respectively to an ammonia transfer device and an anion separation column. The flow configuration results in an ammonium peak before anion peaks in the chromatogram. The system measures ammonia, organic acids (such as acetic, formic, and oxalic acids), HCl, HONO, SO2, HNO3, and the corresponding ions in the aerosol phase. Low ng/m3 to sub-ng/m3 limits of detection (LODs) are attained for most common gases and particulate constituents, the LODs for gaseous SO2 to NH3 range, for example, from sub parts per trillion by volume (sub-pptv) to approximately 5 pptv.

  9. Improvement of the chromatographic separation performance of an imidazolium ionic liquid functionalized silica column by in situ anion-exchange with dodecyl sulfonate and dodecylbenzene sulfonate anions.

    PubMed

    Sun, Min; Feng, Juanjuan; Chen, Wenjie; Li, Leilei; Duan, Huimin; Luo, Chuannan

    2014-06-01

    The anionic part of ionic liquids can provide additional interactions during chromatographic separations. In this work, the chromatographic separation performance of a silica column functionalized with 1-propyl-3-methylimidazolium chloride ionic liquid was improved by in situ anion-exchange from chloride anions to dodecyl sulfonate anions and dodecylbenzene sulfonate anions. The separation performances of these ionic liquid functionalized phases were investigated and compared with each other using polycyclic aromatic hydrocarbons, phthalates, parabens, and phenols as model compounds. Results indicated that the new columns presented a better chromatographic separation than the original one. This was ascribed retention mechanism from organic anions. The introduction of dodecyl sulfonate anions increased the hydrophobicity of stationary phase. Furthermore, the phenyl groups of dodecylbenzene sulfonate anions could provide an enhanced selectivity to aromatic compounds such as polycyclic aromatic hydrocarbons by π-π interactions. Analysis repeatability of the new columns was satisfactory (RSD of retention time, 0.10-0.40%; RSD of peak area, 0.66-0.84%).

  10. Chromatographic separation of PTAD-derivatized 25-hydroxyvitamin D3 and its C-3 epimer from human serum and murine skin.

    PubMed

    Teegarden, Matthew D; Riedl, Kenneth M; Schwartz, Steven J

    2015-06-01

    The detection of 25-hydroxyvitamin D at low levels in biological samples is facilitated by the use of chemical derivatization with 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD) in concert with liquid chromatography-tandem mass spectrometry (LC-MS/MS). This mode of analysis is notably hampered by chromatographic co-elution of 25-hydroxyvitamin D3 (25OHD3) and its C-3 epimer (C3epi). The objective of this work was to improve upon current LC-MS/MS methods used for the analysis of PTAD-derivatized 25-hydroxyvitamin D3 by resolving it from C3epi. Additionally, the applicability of this method in human serum and murine skin was investigated. C18 columns of increasing length and varying particle sizes were assessed for performance using a mixed standard of PTAD-derivatized 25OHD3 and C3epi. Serum samples were processed using solid phase extraction, and skin was powdered and extracted for lipophilic compounds. The samples were derivatized with PTAD and subsequently analyzed using isotope dilution LC-MS/MS with atmospheric pressure chemical ionization operated in positive mode. Near baseline resolution of PTAD-25OHD3 from PTAD-C3epi was achieved on a 250mm C18 column with 3μm sized particles. This separation allowed for detection and quantification of both metabolites in serum and skin samples. PTAD-C3epi represented a significant confounding analyte in all samples, and comprised up to 20% of the status measurement in skin. This method is a significant improvement on the chromatography of PTAD-derivatized vitamin D metabolites that could greatly influence the assessment of vitamin D status and C3epi biology in low abundance samples.

  11. Exploitation of nano alumina for the chromatographic separation of clinical grade 188Re from 188W: a renaissance of the 188W/188Re generator technology.

    PubMed

    Chakravarty, Rubel; Shukla, Rakesh; Ram, Ramu; Venkatesh, Meera; Tyagi, Avesh Kumar; Dash, Ashutosh

    2011-08-15

    The (188)W/(188)Re generator using an acidic alumina column for chromatographic separation of (188)Re has remained the most popular procedure world over. The capacity of bulk alumina for taking up tungstate ions is limited (∼50 mg W/g) necessitating the use of very high specific activity (188)W (185-370 GBq/g), which can be produced only in very few high flux reactors available in the world. In this context, the use of high-capacity sorbents would not only mitigate the requirement of high specific activity (188)W but also facilitate easy access to (188)Re. A solid state mechanochemical approach to synthesize nanocrystalline γ-Al(2)O(3) possessing very high W-sorption capacity (500 mg W/g) was developed. The structural and other investigations of the material were carried out using X-ray diffraction (XRD), transmission electron microscopy (TEM), Brunauer Emmett Teller (BET) surface area analysis, thermogravimetric-differential thermal analysis (TG-DTA), and dynamic light scattering (DLS) techniques. The synthesized material had an average crystallite size of ∼5 nm and surface area of 252 ± 10 m(2)/g. Sorption characteristics such as distribution ratios (K(d)), capacity, breakthrough profile, and elution behavior were investigated to ensure quantitative uptake of (188)W and selective elution of (188)Re. A 11.1 GBq (300 mCi) (188)W/(188)Re generator was developed using nanocrystalline γ-Al(2)O(3), and its performance was evaluated for a period of 6 months. The overall yield of (188)Re was >80%, with >99.999% radionuclidic purity and >99% radiochemical purity. The eluted (188)Re possessed appreciably high radioactive concentration and was compatible for the preparation of (188)Re labeled radiopharmaceuticals.

  12. Deconvolution of gas chromatographic data

    NASA Technical Reports Server (NTRS)

    Howard, S.; Rayborn, G. H.

    1980-01-01

    The use of deconvolution methods on gas chromatographic data to obtain an accurate determination of the relative amounts of each material present by mathematically separating the merged peaks is discussed. Data were obtained on a gas chromatograph with a flame ionization detector. Chromatograms of five xylenes with differing degrees of separation were generated by varying the column temperature at selected rates. The merged peaks were then successfully separated by deconvolution. The concept of function continuation in the frequency domain was introduced in striving to reach the theoretical limit of accuracy, but proved to be only partially successful.

  13. Design of a novel coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with organic-aqueous two-phase solvent systems

    PubMed Central

    Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-01-01

    A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1 = ω2 + ω3. This relation enabled to lay out the flow tube by two different ways, the SS type and the JS type. In the SS type, the flow tube was introduced from the upper side of the apparatus into the sun axis of the first rotary frame and connected to the planet axis of the second rotary frame like a double letter SS. In the JS type, the flow tube was introduced from the bottom of the apparatus into the sun axis reaching the upper side of the planet axis an inversed letter J, followed by distribution as in the SS type. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for lower phase mobile and (1 : 4 : 5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) – CCW (ω2) – CCW (ω3) by the JS type flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) – CW (ω2) – CW (ω3) by the JS type flow tube distribution. A series of experiments on peak resolution and

  14. Carbon-isotopic analysis of dissolved acetate

    NASA Technical Reports Server (NTRS)

    Gelwicks, J. T.; Hayes, J. M.

    1990-01-01

    Heating of dried, acetate-containing solids together with oxalic acid dihydrate conveniently releases acetic acid for purification by gas chromatography. For determination of the carbon-isotopic composition of total acetate, the acetate-containing zone of the chromatographic effluent can be routed directly to a combustion furnace coupled to a vacuum system allowing recovery, purification, and packaging of CO2 for mass-spectrometric analysis. For analysis of methyl carbon, acetic acid can be cryogenically trapped from the chromatographic effluent, then transferred to a tube containing excess NaOH. The tube is evacuated, sealed, and heated to 500 degrees C to produce methane by pyrolysis of sodium acetate. Subsequent combustion of the methane allows determination of the 13C content at the methyl position in the parent acetate. With typical blanks, the standard deviation of single analyses is less than 0.4% for acetate samples larger than 5 micromoles. A full treatment of uncertainties is outlined.

  15. Carbon-isotopic analysis of dissolved acetate.

    PubMed

    Gelwicks, J T; Hayes, J M

    1990-01-01

    Heating of dried, acetate-containing solids together with oxalic acid dihydrate conveniently releases acetic acid for purification by gas chromatography. For determination of the carbon-isotopic composition of total acetate, the acetate-containing zone of the chromatographic effluent can be routed directly to a combustion furnace coupled to a vacuum system allowing recovery, purification, and packaging of CO2 for mass-spectrometric analysis. For analysis of methyl carbon, acetic acid can be cryogenically trapped from the chromatographic effluent, then transferred to a tube containing excess NaOH. The tube is evacuated, sealed, and heated to 500 degrees C to produce methane by pyrolysis of sodium acetate. Subsequent combustion of the methane allows determination of the 13C content at the methyl position in the parent acetate. With typical blanks, the standard deviation of single analyses is less than 0.4% for acetate samples larger than 5 micromoles. A full treatment of uncertainties is outlined.

  16. A Small-Scale Low-Cost Gas Chromatograph

    ERIC Educational Resources Information Center

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  17. Separation of Cu2+, Cd2+ and Cr3+ in a Mixture Solution Using a Novel Carrier Poly(Methyl Thiazoleethyl Eugenoxy Acetate) with BLM (Bulk Liquid Membrane)

    NASA Astrophysics Data System (ADS)

    Djunaidi, M. C.; Khabibi; Ulumudin, I.

    2017-02-01

    The separation process using a novel carrier polyeugenol has active groups N and S has been done with the technique BLM. Polyeugenol has groups active N and S was synthesized from eugenol which is then polymerized into polyeugenol. This polymeric compounds was then acidified become acidic poly (eugenoksi acetate). After the acid formed, then the synthesis was continued by add 4-methyl-5-tiazoleetanol to form esters poly (methyl thiazole eugenoxy ethyl acetate) (PMTEEA). The result of the synthesis was analyzed by FTIR and 1H NMR. This polyester product synthesis was applied as a carrier for separating metal ions Cu2+, Cd2+ and Cr3+ with variations in feed phase pH = 5 and pH = 7 in the membrane of chloroform using techniques BLM. Receiving phase after 24 hours was analyzed by AAS. In variations of feed pH = 5 ions was obtained 66.21% Cd2+, 28.83% Cu2+ and 10.92% of Cr3+, at pH = 7 was obtained 70.77% Cd2+, 30.14% Cu2+, and 3.72% of Cr3+.

  18. Ethyl acetate-n-butanol gradient solvent system for high-speed countercurrent chromatography to screen bioactive substances in okra.

    PubMed

    Ying, Hao; Jiang, Heyuan; Liu, Huan; Chen, Fangjuan; Du, Qizhen

    2014-09-12

    High-speed countercurrent chromatographic separation (HSCCC) possesses the property of zero-loss of sample, which is very useful for the screening of bioactive components. In the present study, the ethyl acetate-n-butanol gradient HSCCC solvent system composed of n-hexane-ethyl acetate-n-butanol-water was investigated for the screening of bioactive substances. To screen the antiproliferative compounds in okra extract, we used the stationary phase ethyl acetate-n-butanol-water (1:1:10) as the stationary phase, and eluted the antiproliferative components by 6-steps of gradient using mobile phases n-hexane-ethyl acetate (1:2), n-hexane-ethyl acetate (1:4), n-hexane-ethyl acetate (0:4), n-butanol-ethyl acetate (1:4) n-butanol-ethyl acetate (1:2), n-butanol-ethyl acetate (2:2), and n-butanol-ethyl acetate (2:1). The fractions collected from HSCCC separation with the gradient solvent system were assayed for antiproliferative activity against cancer cells. Bioactive components were identified: a major anti-cancer compound, 4'-hydroxy phenethyl trans-ferulate, with middle activity, and a minor anti-cancer compound, carolignan, with strong activity. The result shows that the gradient solvent system is potential for the screening of bioactive compounds from natural products.

  19. Chromatographic methods of fractionation.

    PubMed

    Friesen, A D

    1987-01-01

    Chromatography's functional versatility, separation efficiency, gentle non-denaturing separating process and ease of automation and scale-up make it attractive for industrial scale protein purification. The Winnipeg Rh Institute's new Plasma Fractionation facility is an example of the use of chromatography for the large scale purification of plasma protein fractions. The fractionation facility has a capacity to process 800 litres of plasma per batch into blood clotting factor VIII and IX, albumin and intravenous immune serum globulin (i.v. ISG). Albumin and i.v. ISG are purified using ion exchange columns of DEAE-Sepharose (230 litre size), DEAE-Biogel (150 litre size) and CM-Sepharose (150 litre size). The chromatographic process is automated using a Modicon 584 Programmable Logic Controller to regulate valves, pumps and sensors which control plasma flow during fractionation. The stainless steel tanks and piping are automatically cleaned-in-place. The high degree of automation and cleaning provides efficient operation and sanitary processing. Chromatographic methods (DEAE-Sepharose and metal chelation) are also being used at the pilot scale to purify the human blood products superoxide dismutase and hemoglobin from outdated red blood cells. Characterization of the protein fractions produced by chromatography has shown them to be of equal or higher quality than fractions produced by other techniques.

  20. Liquid-chromatographic separation and determination of process-related impurities, including a regio-specific isomer of celecoxib on reversed-phase C18 column dynamically coated with hexamethyldisilazane.

    PubMed

    Rao, R Nageswara; Meena, S; Nagaraju, D; Rao, A Raghuram; Ravikanth, S

    2006-09-01

    A simple and rapid reversed-phase high-performance liquid-chromatographic method for the separation and determination of process-related impurities of celecoxib (CXB) in bulk drugs and pharmaceuticals was developed. The separation of impurities viz., 4-methylacetophenone (I), 1-(4-methylphenyl)-4,4,4-trifluorobutane-1,3-dione (II), 4-hydrazinobenzene sulfonamide (III) and a regio-specific isomer [3-(4-methylphenyl)-5-trifluoromethyl-1H-pyrazole-1-yl]-benzenesulfonamide (IV), was accomplished on an Inertsil ODS-3 column dynamically coated with 0.1% hexamethyldisilazane (HMDS) in acetonitrile:water (55:45 v/v) as a mobile phase and detection at 242 nm using PDA at ambient temperature. The chromatographic conditions were optimized by studying the effects of HMDS, an organic modifier, time of silanization and column temperature. The method was validated and found to be suitable not only for monitoring the synthetic reactions, but also to evaluate the quality of CXB.

  1. Microminiature gas chromatograph

    DOEpatents

    Yu, C.M.

    1996-12-10

    A microminiature gas chromatograph ({mu}GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode. 7 figs.

  2. Microminiature gas chromatograph

    DOEpatents

    Yu, Conrad M.

    1996-01-01

    A microminiature gas chromatograph (.mu.GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode.

  3. Proteome analysis of Myxococcus xanthus by off-line two-dimensional chromatographic separation using monolithic poly-(styrene-divinylbenzene) columns combined with ion-trap tandem mass spectrometry.

    PubMed

    Schley, Christian; Altmeyer, Matthias O; Swart, Remco; Müller, Rolf; Huber, Christian G

    2006-10-01

    Myxobacteria are potent producers of secondary metabolites exhibiting diverse biological activities and pharmacological potential. The proteome of Myxococcus xanthus DK1622 was characterized by two-dimensional chromatographic separation of tryptic peptides from a lysate followed by tandem mass spectrometric identification. The high degree of orthogonality of the separation system employing polymer-based strong cation-exchange and monolithic reversed-phase stationary phases was clearly demonstrated. Upon automated database searching, 1312 unique peptides were identified, which were associated with 631 unique proteins. High-molecular polyketide synthetases and nonribosomal peptide synthetases, known to be involved in the biosynthesis of various secondary metabolites, were readily detected. Besides the identification of gene products associated with the production of known secondary metabolites, proteins could also be identified for six gene clusters, for which no biosynthetic product has been known so far.

  4. Vibrational Spectroscopy of Chromatographic Interfaces

    SciTech Connect

    Jeanne E. Pemberton

    2011-03-10

    Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

  5. A new direct laser photo-induced fluorescence method coupled on-line with liquid chromatographic separation for the simultaneous determination of anilides pesticides.

    PubMed

    Mbaye, O M A; Maroto, A; Gaye-Seye, M D; Stephan, L; Deschamps, L; Aaron, J J; Giamarchi, P

    2015-01-01

    A new direct laser photo-induced fluorescence high performance liquid chromatography (DL-PIF-HPLC) method is developed for the simultaneous determination of three anilide pesticides, namely carboxin, monalide and propanil. DL-PIF-HPLC uses a tunable Nd:YAG-OPO laser to obtain fluorescent photoproduct(s) and to simultaneously analyze their fluorescence in a short acquisition time with an intensified CCD camera, which improves the selectivity (by choosing the suitable excitation wavelength), increases the sensitivity (due to the high energy of the laser beam) and reduces the time of analysis, relative to the classical PIF methods. However, one of the main drawbacks of PIF methods is the presence of interferences with other compounds, such as other pesticides from the same group yielding similar fluorescent photoproducts, which reduces their selectivity. The analytical interest of DL-PIF-HPLC to avoid these interferences is demonstrated. The DL-PIF spectra, chromatographic conditions and analytical performances of DL-PIF-HPLC are presented for the simultaneous determination of three anilide pesticides. The calibration curves are linear over one order of magnitude and the limits of detection are in the ng mL(-1) range. The new DL-PIF-HPLC system has the advantage to combine the performances of both techniques, DL-PIF and liquid chromatography, and to improve the analysis selectivity.

  6. Flecainide acetate acetic acid solvates.

    PubMed

    Veldre, Kaspars; Actiņs, Andris; Eglite, Zane

    2011-02-01

    Flecainide acetate forms acetic acid solvates with 0.5 and 2 acetic acid molecules. Powder X-ray diffraction, differential thermal analysis/thermogravimetric, infrared, and potentiometric titration were used to determine the composition of solvates. Flecainide acetate hemisolvate with acetic acid decomposes to form a new crystalline form of flecainide acetate. This form is less stable than the already known polymorphic form at all temperatures, and it is formed due to kinetic reasons. Both flecainide acetate nonsolvated and flecainide acetate hemisolvate forms crystallize in monoclinic crystals, but flecainide triacetate forms triclinic crystals. Solvate formation was not observed when flecainide base was treated with formic acid, propanoic acid, and butanoic acid. Only nonsolvated flecainide salts were obtained in these experiments.

  7. Layered Poly(ethylene-co-vinyl acetate)/Poly(ethylene-co-vinyl alcohol) Membranes with Enhanced Water Separation Selectivity and Performance.

    PubMed

    Soto Puente, J A; Fatyeyeva, K; Chappey, C; Marais, S; Dargent, E

    2017-02-22

    A three-layered membrane based on poly(ethylene-co-vinyl acetate) (EVA) and hydrolyzed EVA-poly(ethylene-co-vinyl alcohol) (EVOH), was elaborated by the surface hydrolysis of a dense EVA membrane. Because of the chemical modifications, the three-layered EVOH/EVA/EVOH membrane was characterized by the particular microstructure (amorphous EVA and semicrystalline EVOH) and the tunable hydrophilic/hydrophobic balance. Also, these modifications led to the membrane with the selective barrier properties compared with the pure EVA and completely hydrolyzed EVOH membranes. The water barrier behavior was related to the strong hydrogen-bond interactions of water and vinyl alcohol groups, whereas the weak chemical interactions were revealed for gases (N2 and O2). Furthermore, the influence of the polymer rubbery or glassy state on the permeation kinetics was established. In the case of the three-layered membrane, the considerably high selectivity values were obtained for H2O/O2 (∼11 900) and H2O/N2 (∼48 000) at 25 °C. In addition to these highly selective properties, the three-layered structure does not present delamination features due to its elaboration procedure. Thus, these new layered membranes are very promising as selective materials for the water and gas separation and can be potentially used in food packaging or for the gas dehydration.

  8. [A chromatographic method of determining the levels of organic solvents in the air, the components of the offset lacquer LO-2].

    PubMed

    Dobecki, M; Czerczak, S

    1987-01-01

    A gas chromatographic method was worked out to determine the mixture of ethyl acetate, toluene, buthyl acetate, p,m-xylene, o-xylene and ethyl ethylene glycol vapours. These solvents are used as some components of offset lacquer LO-2. Optimum separation conditions were achieved on 3-metre SS column filled with 10% FFAP on Chormosorb W AW DMCS 80-100 mesh. Air samples were collected on activated charcoal placed in glass tubes. The components tested were desorbed from the sorbent material by 10% acetone solution in CS2. The method enables to determine the concentrations of each compound, corresponding to one fifth of their TLVs.

  9. High-separation efficiency micro-fabricated multi-capillary gas chromatographic columns for simulants of the nerve agents and blister agents

    NASA Astrophysics Data System (ADS)

    Li, Yi; Du, Xiaosong; Wang, Yang; Tai, Huiling; Qiu, Dong; Lin, Qinghao; Jiang, Yadong

    2014-05-01

    To achieve both high speed and separation efficiency in the separation of a mixture of nerve and blister agent simulants, a high-aspect-ratio micro-fabricated multi-capillary column (MCC, a 50-cm-long, 450-μm-deep, and 60-μm-wide four-capillary column) was fabricated by the application of the microelectromechanical system (MEMS) techniques. Mixtures of chemical warfare agent (CWA) simulants - dimethyl methylphosphonate (DMMP), triethyl phosphate (TEP), and methyl salicylate - were used as samples. The fabricated MCC allowed for the separation of all the components of the gaseous mixture within 24 s, even when the difference in boiling point was 4°C, as in the case of TEP and methyl salicylate. Furthermore, interfering agents - dichloromethane, ethanol, and toluene - were also included in the subsequent gaseous mixture samples. The boiling point of these six components ranged from 78°C to 219°C. All six components were clearly separated within 70 s. This study is the first to report the clear separation of gas mixtures of components with close boiling points. The column efficiency was experimentally determined to be 12,810 plates/m.

  10. High-separation efficiency micro-fabricated multi-capillary gas chromatographic columns for simulants of the nerve agents and blister agents

    PubMed Central

    2014-01-01

    To achieve both high speed and separation efficiency in the separation of a mixture of nerve and blister agent simulants, a high-aspect-ratio micro-fabricated multi-capillary column (MCC, a 50-cm-long, 450-μm-deep, and 60-μm-wide four-capillary column) was fabricated by the application of the microelectromechanical system (MEMS) techniques. Mixtures of chemical warfare agent (CWA) simulants - dimethyl methylphosphonate (DMMP), triethyl phosphate (TEP), and methyl salicylate - were used as samples. The fabricated MCC allowed for the separation of all the components of the gaseous mixture within 24 s, even when the difference in boiling point was 4°C, as in the case of TEP and methyl salicylate. Furthermore, interfering agents - dichloromethane, ethanol, and toluene - were also included in the subsequent gaseous mixture samples. The boiling point of these six components ranged from 78°C to 219°C. All six components were clearly separated within 70 s. This study is the first to report the clear separation of gas mixtures of components with close boiling points. The column efficiency was experimentally determined to be 12,810 plates/m. PMID:24899869

  11. Computer simulation for the convenient optimization of isocratic reversed-phase liquid chromatographic separations by varying temperature and mobile phase strength.

    PubMed

    Wolcott, R G; Dolan, J W; Snyder, L R

    2000-02-11

    Software is described which allows the rapid development of separations by means of isocratic reversed-phase liquid chromatography (RP-LC), based on the optimization of column temperature (T) and mobile phase strength (%B). For a given sample, four initial experiments are carried out at two different temperatures, using either isocratic or (better) gradient elution. If isocratic experiments are chosen for computer simulation, it is necessary to select appropriate values of %B for these initial runs. Literature data for solute retention as a function of T are reviewed, as a basis for estimating suitable values of %B at the two values of T selected. The use of optimized values of T and %B led to acceptable separations for three representative samples. The prediction of isocratic separation on the basis of initial gradient experiments is more convenient than the use of initial isocratic experiments, but less reliable. When gradient experiments are used, one additional isocratic experiment can improve the accuracy of such predictions by a "reflection" procedure. The latter approach was confirmed for predictions of both isocratic and gradient separation from initial gradient experiments.

  12. High-performance liquid chromatographic separations of stereoisomers of chiral basic agrochemicals with polysaccharide-based chiral columns and polar organic mobile phases.

    PubMed

    Matarashvili, Iza; Shvangiradze, Iamze; Chankvetadze, Lali; Sidamonidze, Shota; Takaishvili, Nino; Farkas, Tivadar; Chankvetadze, Bezhan

    2015-12-01

    The separation of the stereoisomers of 23 chiral basic agrochemicals was studied on six different polysaccharide-based chiral columns in high-performance liquid chromatography with various polar organic mobile phases. Along with the successful separation of analyte stereoisomers, emphasis was placed on the effect of the chiral selector and mobile phase composition on the elution order of stereoisomers. The interesting phenomenon of reversal of enantiomer/stereoisomer elution order function of the polysaccharide backbone (cellulose or amylose), type of derivative (carbamate or benzoate), nature, and position of the substituent(s) in the phenylcarbamate moiety (methyl or chloro) and the nature of the mobile phase was observed. For several of the analytes containing two chiral centers all four stereoisomers were resolved with at least one chiral selector/mobile phase combination.

  13. Counter-current chromatographic separation of glycoprotein components from Morchella esculenta (L.) with a polymer phase system by a cross-axis coil planet centrifuge.

    PubMed

    Wei, Y; Zhang, T; Ito, Y

    2001-05-11

    Using a cross-axis coil planet centrifuge, glycoproteins were separated from fermentation media of Morchella esculenta (L.) by high-speed counter-current chromatography. The performance of the apparatus was optimized with four standard proteins including pepsin, lysozyme, ovalbumin and hemoglobin and a polymer phase system composed of 12.5% (w/w) polyethylene glycol 8000 and 25% (w/w) potassium phosphate in distilled water at various pH values. Separations were performed by eluting the lower phosphate-rich phase at a flow-rate of 1.0 ml/min. Under the optimized conditions three glycoprotein components in Morchella esculenta (L.) were resolved within 6 h.

  14. Performance comparison of three types of high-speed counter-current chromatographs for the separation of components of hydrophilic and hydrophobic color additives.

    PubMed

    Weisz, Adrian; Ito, Yoichiro

    2011-09-09

    The performance of three types of high-speed counter-current chromatography (HSCCC) instruments was assessed for their use in separating components in hydrophilic and hydrophobic dye mixtures. The HSCCC instruments compared were: (i) a J-type coil planet centrifuge (CPC) system with a conventional multilayer-coil column, (ii) a J-type CPC system with a spiral-tube assembly-coil column, and (iii) a cross-axis CPC system with a multilayer-coil column. The hydrophilic dye mixture consisted of a sample of FD&C Blue No. 2 that contained mainly two isomeric components, 5,5'- and 5,7'-disulfonated indigo, in the ratio of ∼7:1. The hydrophobic dye mixture consisted of a sample of D&C Red No. 17 (mainly Sudan III) and Sudan II in the ratio of ∼4:1. The two-phase solvent systems used for these separations were 1-butanol/1.3M HCl and hexane/acetonitrile. Each of the three instruments was used in two experiments for the hydrophilic dye mixture and two for the hydrophobic dye mixture, for a total of 12 experiments. In one set of experiments, the lower phase was used as the mobile phase, and in the second set of experiments, the upper phase was used as the mobile phase. The results suggest that: (a) use of a J-type instrument with either a multilayer-coil column or a spiral-tube assembly column, applying the lower phase as the mobile phase, is preferable for separating the hydrophilic components of FD&C Blue No. 2; and (b) use of a J-type instrument with multilayer-coil column, while applying either the upper phase or the lower phase as the mobile phase, is preferable for separating the hydrophobic dye mixture of D&C Red No. 17 and Sudan II.

  15. Chromatographic and spectroscopic studies on the chiral recognition of sulfated beta-cyclodextrin as chiral mobile phase additive enantiomeric separation of a chiral amine.

    PubMed

    Ma, Shengli; Shen, Sherry; Haddad, Nizar; Tang, Wenjun; Wang, Jing; Lee, Heewon; Yee, Nathan; Senanayake, Chris; Grinberg, Nelu

    2009-02-20

    A fast enantiomeric separation of a chiral aromatic amine was achieved, using ultra high pressure liquid chromatography and highly sulfated beta-cyclodextrin (S-beta-CD) as a chiral additive in the mobile phase. The stationary phase consisted of a core-shell support with a particle size of 2.7mum. Under these conditions the base-line separation was obtained within 2.5min. The influence of the concentration of the additive, along with the thermodynamics of the separation, was studied. Vibrational circular dichroism (VCD) spectroscopy was applied to assess the absolute configuration of the two enantiomeric analytes, as well as the interaction of these enantiomers with the S-beta-CD. The VCD results revealed that S-beta-CD undergoes a temperature-induced conformational change. Further, VCD experiments indicate that the interactions of the two enantiomers with the S-beta-CD occur through an inclusion of the aromatic part of the analyte, as well as through electrostatic interaction between the protonated amine and the sulfate groups located at the narrow part of the S-beta-CD. Molecular mechanics calculations performed according to the VCD results are consistent with experimental data, providing further evidence of these interactions.

  16. Bioactivity of Diterpens from the Ethyl Acetate Extract of Kingiodendron pinnatum Rox. Hams

    PubMed Central

    Javarappa, Komal Kumar; Prasad, Attemode Girijanna Devi; Mahadesh Prasad, AJ; Mane, Chetana

    2016-01-01

    Background: Kingiodendron pinnatum Rox. Hams. is an endangered medicinal plant used in gonorrhoe, catarrhal conditions of genito-urinary and respiratory tracts. The scientific and pharmacological formulation of K. pinnatum has not been established so far though it is being traditionally used by tribes of the region. Objective: P hytochemical screening and identification of the bioactive compounds from the ethyl acetate extract of Kingiodendron pinnatum Rox. Hams. Materials and Methods: Chromatographic separation was carried out by thin layer chromatography and column chromatography. Bio-autography of the column fractioned extract and TLC chromatogram were evaluated in vitro for antibacterial activity. The PTLC, HP TLC were used for crude extract and HPLC, LCMS, FTIR, 1HNMR and 13CNMR were employed for the isolated compound in the ethyl acetate extract of K. pinnatum. Results: Evaluation of solvent system for chromatographic separation revealed that ethyl acetate: petroleum ether in the ratio of 7:2.5 ml was the most appropriate one for the separation of diterpene compounds. The antibacterial bio-autography screening of TLC separated compound showed positive activity with Staphylococcus aureus and negative activity with Escherichia coli. Spectroscopic analysis of the isolated compound from the ethyl acetate extract of K. pinnatum revealed the presence of diterpene compound. Conclusion: It is evident from the present study that the ethyl acetate extract of K. pinnatum is rich in diterpene compounds and having potential antibacterial activity. SUMMARY Novel extraction method for phytochemicls from Kingidendron pinnatum at RTAntibacterial property of diterpens extracted from Kingiodendron pinnatum Rox. Hams aganist S. aureus Abbreviations Used: TLC: Thin Layer Chromatography, PTLC: Preparatory Thin Layer Chromatography, HPTLC: High perormence Thin Layer chromatography, HPLC: High Performance Liquid Chromatography, LC-MS: Liquid chromatography Mass Spectra, FTIR

  17. A simple cellulose acetate membrane-based small lanes technique for protein electrophoresis.

    PubMed

    Na, Na; Liu, Tingting; Yang, Xiaojun; Sun, Binjie; Ouyang, Jenny; Ouyang, Jin

    2012-08-01

    Combining electrophoresis with a cellulose acetate membrane-based technique, we developed a simple and low-cost method, named cellulose acetate membrane-based small lanes (CASL), for protein electrophoresis. A home-made capillary plotter controlled by a 3D moving stage was used to create milli-to-micro channels by printing poly(dimethylsiloxane) on to a hydrophilic cellulose acetate membrane. In the hydrophilic channels, 5 nL protein mixture was separated on the basis of electro-migration under an electric field. Compared with polyacrylamide gel electrophoresis (PAGE), CASL resulted in higher protein signal intensity for separation of mixtures containing the same mass of protein. The platform was easily fabricated at low cost (approx. $0.005 for each 1-mm-wide channel), and separation of three protein mixtures was completed in 15 min. Both electrophoresis time and potential affected the separation. Rather than chromatographic separation, this method accomplished application of microchannel techniques for cellulose acetate membrane-based protein electrophoresis. It has potential in proteomic analysis, especially for rapid, low-cost, and low-volume sample analysis in clinical diagnosis.

  18. Ultra high pressure in the second dimension of a comprehensive two-dimensional liquid chromatographic system for carotenoid separation in red chili peppers.

    PubMed

    Cacciola, Francesco; Donato, Paola; Giuffrida, Daniele; Torre, Germana; Dugo, Paola; Mondello, Luigi

    2012-09-14

    A comprehensive normal-phase × reversed-phase (NP-LC × RP-LC) liquid chromatography system was developed, and applied for analysis of the intact carotenoid composition of red chili peppers, with photodiode array and mass spectrometry detection. A micro-bore cyano column (250 mm × 1.0 mm, 5 μm d.p.) was chosen for the first dimension ((1)D) separation, interfaced to a second dimension ((2)D) C18 column (30 mm × 4.6 mm, 2.7 μm d.p.) packed with fused-core particles. Subsequently, two columns of the same stationary phase were coupled serially for second dimension separation, and operated under ultra high pressure LC conditions (UHPLC), within a cycle time of 1.50 or 1.00 min, and equal modulation times. Performances of the three different set-ups were evaluated, in terms of peak capacity values (n(c)), and afterwards corrected by taking into account both the under-sampling, and the orthogonality effects. After these adjustments, the peak capacity values were estimated as follows: n(c) 526, for the NP-LC × RP-LC system, n(c) 373, for the NP-LC × RP-UHPLC system with a 1.50 min modulation time, n(c) 639, for the NP-LC × RP-UHPLC system, with a 1.00 min modulation time. A total of 33 compounds were separated into 10 different chemical classes in the two-dimensional space, and identified by accurate IT-TOF (ion trap-time of flight) MS detection.

  19. New reversed phase-high performance liquid chromatographic method for selective separation of yttrium from all rare earth elements employing nitrilotriacetate complexes in anion exchange mode.

    PubMed

    Dybczyński, Rajmund S; Kulisa, Krzysztof; Pyszynska, Marta; Bojanowska-Czajka, Anna

    2015-03-20

    Separation of Y from other rare earth elements (REE) is difficult because of similarity of its ionic radius to ionic radii of Tb, Dy and Ho. In the new RP-HPLC system with C18 column, tetra-n-butyl ammonium hydroxide (TBAOH) as an ion interaction reagent (IIR), nitrilotriacetic acid (NTA) as a complexing agent at pH=2.8-3.5, and post column derivatization with Arsenazo III, yttrium is eluted in the region of light REE, between Nd and Sm and is base line separated from Nd and Sm and even from promethium. Simple model employing literature data on complex formation of REE with NTA and based on anion exchange mechanism was developed to foresee the order of elution of individual REE. The model correctly predicted that lanthanides up to Tb will be eluted in the order of increasing Atomic Number (At.No.) but all heavier REE will show smaller retention factors than Tb. Concurrent UV/VIS detection at 658nm and the use of radioactive tracers together with γ-ray spectrometric measurements made possible to establish an unique elution order of elution of REE: La, Ce, Pr, Nd, Pm, Y, Sm, Er, Ho, Tm, Yb, Eu, Lu, Dy+Gd, Tb, Sc. The real place of Y however, in this elution series differs from that predicted by the model (Y between Sm and Eu). The method described in this work enables selective separation of Y from La, Ce, Pr, Nd, Pm, Sm and all heavier REE treated as a group.

  20. Mesoxalaldehyde acetals

    SciTech Connect

    Gordeeva, G.N.; Kalashnikov, S.M.; Popov, Yu.N.; Kruglov, E.A.; Imashev, U.B.

    1987-11-10

    The treatment of methylglyoxal acetals by alkyl nitrites in the presence of the corresponding aliphatic alcohols and hydrochloric acid leads to the formation of linear mesoxalaldehyde acetals, whose structure was established by NMR spectroscopy and mass spectrometry. The major pathways for the decomposition of these molecules upon electron impact were established.

  1. Coal liquefaction process streams characterization and evaluation: Application of liquid chromatographic separation methods to THF-soluble portions of integrated two-stage coal liquefaction resids

    SciTech Connect

    Green, J.B.; Pearson, C.D.; Young, L.L.; Green, J.A. )

    1992-05-01

    This study demonstrated the feasibility of using non-aqueous ion exchange liquid chromatography (NIELC) for the examination of the tetrahydrofuran (THF)-soluble distillation resids and THF-soluble whole oils derived from direct coal liquefaction. The technique can be used to separate the material into a number of acid, base, and neutral fractions. Each of the fractions obtained by NIELC was analyzed and then further fractionated by high-performance liquid chromatography (HPLC). The separation and analysis schemes are given in the accompanying report. With this approach, differences can be distinguished among samples obtained from different process streams in the liquefaction plant and among samples obtained at the same sampling location, but produced from different feed coals. HPLC was directly applied to one THF-soluble whole process oil without the NIELC preparation, with limited success. The direct HPLC technique used was directed toward the elution of the acid species into defined classes. The non-retained neutral and basic components of the oil were not analyzable by the direct HPLC method because of solubility limitations. Sample solubility is a major concern in the application of these techniques.

  2. Thermodynamic characteristics of sorption extraction and chromatographic separation of anionic complexes of erbium and cerium with Trilon B on weakly basic anionite

    NASA Astrophysics Data System (ADS)

    Cheremisina, O. V.; Ponomareva, M. A.; Sagdiev, V. N.

    2016-03-01

    The adsorption of anionic complexes of erbium with Trilon B on D-403 anionite is studied at ionic strengths of 1 and 2 mol/kg (NaNO3) and temperatures of 298 and 343 K. The values of the stability constants of complex ions of REE with Trilon B and the Gibbs energies of complexation are calculated. The values of the Gibbs energy and the enthalpy and entropy of ion exchange are determined. Using the obtained thermo-dynamic and sorption characteristics, the possible separation of anionic complexes of erbium and cerium with Trilon B is demonstrated via frontal ion-exchange chromatography. A series of sorption capacities of anionic complexes of cerium, yttrium, and erbium is presented using the values of the Gibbs energy of ion exchange.

  3. In-line respeciation: an ion-exchange ion chromatographic method applied to the separation of degradation products of chemical warfare nerve agents in soil.

    PubMed

    Vermillion, W D; Crenshaw, M D

    1997-05-16

    The natural background of anions encountered when analyzing soil samples by ion chromatography (IC) present significant problems in the separation, detection and quantification of isopropyl methylphosphonic acid (IMPA) and methylphosphonic acid (MPA), the degradation products of sarin, a chemical warfare nerve agent. Using chemically-suppressed IC with conductivity detection, a commercially available ion-exchange column, and an isocratic binary eluent system, IMPA and MPA were determined in aqueous extracts of soil at sub-ppm (microgram/g) concentrations without the need for gradient elution or organic solvent eluent modifiers. Common soil anions such as chloride, nitrate, sulfate and phosphate do not interfere with the analysis method due to the composition of the binary eluent allowing for greater mobilization of multivalent anions (e.g., MPA, carbonate, and sulfate) while monovalent anions (e.g., IMPA and nitrate) are relatively unaffected. Carbonate is selectively removed by in-line respeciation to bicarbonate.

  4. Role of substituents in cyclodextrin derivatives for enantioselective gas chromatographic separation of chiral terpenoids in the essential oils of Mentha spicata.

    PubMed

    Pragadheesh, V S; Yadav, Anju; Chanotiya, Chandan Singh

    2015-10-01

    Enantioselective GC-FID and enantioselective GC-MS have been utilized under temperature gradient mode with differently substituted heptakis- and octakis-cyclodextrins to achieve the resolution of chiral terpenoids in the essential oil of indigenously grown cultivars of Mentha spicata. Modified cyclodextrins were derivatized in GC column for the separation of chiral terpenoids. A 2,3-diethyl-6-tert-butyldimethylsilyl-β-cyclodextrin doped into 14% cyanopropylphenyl/86%dimethylpolysiloxane (TBDE-β-CD) showed good enantioselectivity for all the studied chiral compounds excluding carvone. Carvone enantiomers were well resolved in 2,3-diacetoxy-6-tert-butyldimethylsilyl-β-cyclodextrin column (TBDA-β-CD) with enantioseparation (Es) of 1.006. A TBDE-β-CD provides maximum enantiomeric separation for β-pinene (Es 1.038), sabinene (Es 1.051), limonene (Es 1.045), isomenthone (Es 1.029) and α-terpineol (Es 1.014). Furthermore, enantiomer elution order reversal was observed for sabinene, menthone, terpinen-4-ol and menthol while changing from β- to γ-cyclodextrin phase. Carvone exhibits enantiomer elution order reversal by changing substituents i.e., methyl to acetyl at 2- & 3- position of the cyclodextrin derivative. Chiral constituents such as (+)-isomenthone, (-)-menthone, (1R,2S,5R)-(-)-menthol and (4S)-(+)-piperitone exist as a single enantiomer with >99% excess. Existence of (R)-(+)-limonene and (S)-(+)-carvone enantiomers has been proven first time in M. spicata essential oils and can be used as the marker for Indian origin.

  5. Effect of monomer mixture composition on structure and chromatographic properties of poly(divinylbenzene-co-ethylvinylbenzene-co-2-hydroxyethyl methacrylate) monolithic rod columns for separation of small molecules.

    PubMed

    Smirnov, Konstantin N; Dyatchkov, Ivan A; Telnov, Maxim V; Pirogov, Andrey V; Shpigun, Oleg A

    2011-07-29

    Porous poly(divinylbenzene-co-ethylvinylbenzene-co-2-hydroxyethyl methacrylate) monoliths were synthesized via thermally initiated free-radical polymerization in confines of surface-vinylized glass columns (150 mm × 3 mm i.d.) and applied to the reversed-phase separation of low-molecular-weight aromatic compounds. In order to compensate for the polymer shrinkage during the synthesis and prevent the monolith from detachment from the column wall, polymerization was conducted under nitrogen pressure. The reaction proceeded at 60°C for 22 h. 2,2'-Azo-bis-isobutironitrile was used as the initiator and 1-dodecanol was used as the porogen. A series of monoliths with different monomer ratios were obtained. All the monoliths had high specific surface areas ranging from 370 to 490 m(2)/g. In the studied range of monomer mixture compositions, the mechanical stability of the stationary phase in water/acetonitrile eluents was found to be high enough and practically insensitive to the fraction of 2-hydroxyethyl methacrylate (HEMA). Increasing the molar fraction of HEMA from 10.5% to 14.7% resulted in the decrease of column permeability by two orders of magnitude (from 1.1×10(-12) to 1.8×10(-14) m(2)) and led to weaker retention of alkylbenzenes. The higher HEMA content was shown to reduce the plate height of the columns in the separation of small molecules from 160-490 μm to 40-76 μm. This was attributed mainly to the decrease of the domain size of the monoliths leading to lower eddy dispersion and mass transfer resistance in the column.

  6. Chromatographic resolution of drug analogues: 3-hydroxy-3-methylglutarylcoenzyme A reductase inhibitors (statins).

    PubMed

    Tahir, Muhammad Saqlain; Adnan, Ahmad; Syed, Quratulain

    2016-05-01

    A high performance liquid chromatographic method for the simultaneous determination both qualitative and quantitative of cholesterol lowering statin drugs in pharmaceutical formulations has been developed. The most important advantage of developed method is that all seven statin drugs can be determined on a single chromatographic system without modification in detection wavelength. An organic modifier addition (25% v/v methanol) in the presence of buffer (20mM ammonium acetate; pH 4.0 adjusted with dilute acetic acid) played a key role in the resolution of statin drugs in gradient elution with acetonitrile. The drugs were separated on a Purospher Star 4.6mm × 25cm, 5μm, C18 column maintained at 25°C with 1mLmin(-1) flow rate using ultra violet detection at 240nm. Good separation (Rs > 2.5) was achieved in a short analysis allowing simultaneous determination of all seven statins. The effect of variation in flow rate, detection wavelength and column oven temperature was also studied. The proposed method was statistically validated in terms of precision, accuracy, linearity, specificity and robustness. The newly developed method proved to be specific, robust and accurate for the quantification of seven statins in commercial pharmaceutical formulations.

  7. Stacking open-capillary electroosmotic pumps in series to boost the pumping pressure to drive high-performance liquid chromatographic separations.

    PubMed

    He, Chiyang; Zhu, Zaifang; Gu, Congying; Lu, Joann; Liu, Shaorong

    2012-03-02

    Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet and outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (∼3100 psi). We further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides.

  8. Stacking open-capillary electroosmotic pumps in series to boost the pumping pressure to drive high-performance liquid chromatographic separations

    DOE PAGES

    He, Chiyang; Zhu, Zaifang; Gu, Congying; ...

    2012-01-09

    Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet andmore » outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (~3100 psi). Here, we further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides.« less

  9. Stacking open-capillary electroosmotic pumps in series to boost the pumping pressure to drive high-performance liquid chromatographic separations

    SciTech Connect

    He, Chiyang; Zhu, Zaifang; Gu, Congying; Lu, Joann; Liu, Shaorong

    2012-01-09

    Numerous micropumps have been developed, but few of them can produce adequate flow rate and pressure for high-performance liquid chromatography (HPLC) applications. We have recently developed an innovative hybrid electroosmotic pump (EOP) to solve this problem. The basic unit of a hybrid pump consists of a +EOP (the pumping element is positively charged) and a -EOP (the pumping element is negatively charged). The outlet of the +EOP is then joined with the inlet of the -EOP, forming a basic pump unit, while the anode of a positive high voltage (HV) power supply is placed at the joint. The inlet and outlet of this pump unit are electrically grounded. With this configuration, we can stack many of such pump units in series to boost the pumping power. In this work, we describe in details how an open-capillary hybrid EOP is constructed and characterize this pump systematically. We also show that a hybrid EOP with ten serially stacked pump units can deliver a maximum pressure of 21.5 MPa (~3100 psi). Here, we further demonstrate the feasibility of using this hybrid EOP to drive eluents for HPLC separations of proteins and peptides.

  10. Simultaneous spectrophotometric determination of phosphate and silicate ions in river water by using ion-exclusion chromatographic separation and post-column derivatization.

    PubMed

    Nakatani, Nobutake; Kozaki, Daisuke; Masuda, Wakako; Nakagoshi, Nobukazu; Hasebe, Kiyoshi; Mori, Masanobu; Tanaka, Kazuhiko

    2008-06-30

    The simultaneous spectrophotometric determination of phosphate and silicate ions in river water was examined by using ion-exclusion chromatography and post-column derivatization. Phosphate and silicate ions were separated by the ion-exclusion column packed with a polymethacrylate-based weakly acidic cation-exchange resin in the H(+)-form (TSKgel Super IC-A/C) by using ultra pure water as an eluent. After the post-column derivatization with molybdate and ascorbic acid, so-called molybdenum-blue, both ions were determined simultaneously by spectrophotometry. The effects of sulfuric acid, sodium molybdate and ascorbic acid concentrations and reaction coil length, which have relation to form the reduced complexes of molybdate and ions, on the detector response for phosphate and silicate ions were investigated. Under the optimized conditions (color-forming reactant, 50 mM sulfuric acid-10 mM sodium molybdate; reducing agent, 50 mM ascorbic acid; reaction coil length, 6 m), the calibration curves of phosphate and silicate ions were linear in the range of 50-2000 microg L(-1) as P and 250-10,000 microg L(-1) as Si. This method was successfully applied to water quality monitoring of Kurose-river watershed and it suggested that the effluent from a biological sewage treatment plant was significant source of phosphate ion in Kurose-river water.

  11. Strong anion exchange liquid chromatographic separation of protein amino acids for natural 13C-abundance determination by isotope ratio mass spectrometry.

    PubMed

    Abaye, Daniel A; Morrison, Douglas J; Preston, Tom

    2011-02-15

    Amino acids are the building blocks of proteins and the analysis of their (13)C abundances is greatly simplified by the use of liquid chromatography (LC) systems coupled with isotope ratio mass spectrometry (IRMS) compared with gas chromatography (GC)-based methods. To date, various cation exchange chromatography columns have been employed for amino acid separation. Here, we report strong anion exchange chromatography (SAX) coupled to IRMS with a Liquiface interface for amino acid δ(13)C determination. Mixtures of underivatised amino acids (0.1-0.5 mM) and hydrolysates of representative proteins (prawns and bovine serum albumin) were resolved by LC/IRMS using a SAX column and inorganic eluents. Background inorganic carbon content was minimised through careful preparation of alkaline reagents and use of a pre-injector on-line carbonate removal device. SAX chromatography completely resolved 11 of the 16 expected protein amino acids following acid hydrolysis in underivatised form. Basic and neutral amino acids were resolved with 35 mM NaOH in isocratic mode. Elution of the aromatic and acidic amino acids required a higher hydroxide concentration (180 mM) and a counterion (NO 3-, 5-25 mM). The total run time was 70 min. The average δ(13)C precision of baseline-resolved peaks was 0.75‰ (range 0.04 to 1.06‰). SAX is a viable alternative to cation chromatography, especially where analysis of basic amino acids is important. The technology shows promise for (13)C amino acid analysis in ecology, archaeology, forensic science, nutrition and protein metabolism.

  12. Concurrent liquid-chromatographic assay of retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in plasma, with tocopherol acetate as internal standard.

    PubMed

    Thurnham, D I; Smith, E; Flora, P S

    1988-02-01

    A method is described for simultaneously determining retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin in 0.25 mL of plasma. Plasma mixed with sodium dodecyl sulfate is deproteinized with ethanol containing tocopherol acetate, then extracted with heptane. The evaporated organic layer is reconstituted with mobile phase (methanol/acetonitrile/chloroform, 47/47/6 by vol) and injected onto a 100 x 4.6 mm 3-micron column of Spherisorb ODS-2 (LKB) at 1.5 mL/min. The alpha- and beta-carotenes are well resolved during the 6.5-min run. Retinol is monitored at 325 nm, the tocopherols at 292 nm, and the carotenoids at 450 nm. Extraction of concentrations as great as 135 mumol/L is complete. Intrabatch CVs were 1.7%, 2.3%, 4.1%, 10.4%, 6.4%, and 3.6% for retinol, alpha-tocopherol, beta-carotene, alpha-carotene, lycopene, and beta-cryptoxanthin, respectively. Interbatch CVs for measurements on 30 occasions over 11 weeks were about 10% for all components except alpha-tocopherol (5.3%). Results agree well with those for retinol, alpha-tocopherol, and beta-carotene in quality-control samples.

  13. Partial least squares model and design of experiments toward the analysis of the metabolome of Jatropha gossypifolia leaves: Extraction and chromatographic fingerprint optimization.

    PubMed

    Pilon, Alan Cesar; Carnevale Neto, Fausto; Freire, Rafael Teixeira; Cardoso, Patrícia; Carneiro, Renato Lajarim; Da Silva Bolzani, Vanderlan; Castro-Gamboa, Ian

    2016-03-01

    A major challenge in metabolomic studies is how to extract and analyze an entire metabolome. So far, no single method was able to clearly complete this task in an efficient and reproducible way. In this work we proposed a sequential strategy for the extraction and chromatographic separation of metabolites from leaves Jatropha gossypifolia using a design of experiments and partial least square model. The effect of 14 different solvents on extraction process was evaluated and an optimized separation condition on liquid chromatography was estimated considering mobile phase composition and analysis time. The initial conditions of extraction using methanol and separation in 30 min between 5 and 100% water/methanol (1:1 v/v) with 0.1% of acetic acid, 20 μL sample volume, 3.0 mL min(-1) flow rate and 25°C column temperature led to 107 chromatographic peaks. After the optimization strategy using i-propanol/chloroform (1:1 v/v) for extraction, linear gradient elution of 60 min between 5 and 100% water/(acetonitrile/methanol 68:32 v/v with 0.1% of acetic acid), 30 μL sample volume, 2.0 mL min(-1) flow rate, and 30°C column temperature, we detected 140 chromatographic peaks, 30.84% more peaks compared to initial method. This is a reliable strategy using a limited number of experiments for metabolomics protocols.

  14. Ion chromatographic identification and quantification of glycol degradation products.

    PubMed

    Madera, M; Höflinger, W; Kadnar, R

    2003-05-16

    In water-based heat transfer systems, frequently glycols are added to the water to obtain freeze protection. For this purpose, ethylene glycol (EG) is the most common substance used. When heated, the glycol will slowly degrade and the pH of the glycol-water mixture will decrease, leading to corrosion and foaming problems. Carboxylic acids were identified as the main degradation products. Quantification of the carboxylic acids is of importance to monitor the degradation reactions in order to identify hot spots or overheating, caused by severe heat exchanger scaling, where pH measurements will not be sufficient due to buffer substances added for corrosion protection. In this work, ion chromatographic methods havebeen developed to identify the main degradation products of EG in heat transfer systems and to monitor the degradation process. Possible acidic reaction products of EG are glycolic acid, glyoxylic acid, oxalic acid, acetic acid and formic acid. Separations with a Dionex AS9-HC column with Na2CO3 eluents of differing concentrations showed that only trace amounts of carboxylic acids are present in aged heat transfer media. Oxalic acid can be quantified simultaneously to nitrite or molybdate which are added as corrosion inhibitors. A Dionex AS10 separation column with Na2B4O7 eluent enabled base line separation of glycolic acid, acetic acid and formic acid. Heat transfer media, which are operated in different heat transfer systems under different conditions, were analysed. A system was identified, where severe overheating due to fluid maldistribution in the heat exchanger took place.

  15. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  16. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  17. Thallium acetate

    Integrated Risk Information System (IRIS)

    Jump to main content . Integrated Risk Information System Recent Additions | Contact Us Search : All EPA IRIS • You are here : EPA Home • Research • Environmental Assessment • IRIS • IRIS Summaries Redirect Page As of September 30 , 2009 , the assessment summary for Thallium acetate is included in t

  18. Phenylmercuric acetate

    Integrated Risk Information System (IRIS)

    Phenylmercuric acetate ; CASRN 62 - 38 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog

  19. Ethyl acetate

    Integrated Risk Information System (IRIS)

    Ethyl acetate ; CASRN 141 - 78 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  20. Ammonium acetate

    Integrated Risk Information System (IRIS)

    Ammonium acetate ; CASRN 631 - 61 - 8 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic

  1. Vinyl acetate

    Integrated Risk Information System (IRIS)

    Vinyl acetate ; CASRN 108 - 05 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  2. Comparison of the peak resolution and the stationary phase retention between the satellite and the planetary motions using the coil satellite centrifuge with counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives.

    PubMed

    Shinomiya, Kazufusa; Zaima, Kazumasa; Harada, Yukina; Yasue, Miho; Harikai, Naoki; Tokura, Koji; Ito, Yoichiro

    2017-01-20

    Coil satellite centrifuge (CSC) produces the complex satellite motion consisting of the triplicate rotation of the coiled column around three axes including the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3) according to the following formula: ω1=ω2+ω3. Improved peak resolution in the separation of 4-methylumbelliferyl sugar derivatives was achieved using the conventional multilayer coiled columns with ethyl acetate/1-butanol/water (3: 2: 5, v/v) for the lower mobile phase at the combination of the rotation speeds (ω1, ω2, ω3)=(300, 150, 150rpm), and (1:4:5, v/v) for the upper mobile phase at (300:100:200rpm). The effect of the satellite motion on the peak resolution and the stationary phase retention was evaluated by each CSC separation with the different rotation speeds of ω2 and ω3 under the constant revolution speed at ω1=300rpm. With the lower mobile phase, almost constant peak resolution and stationary phase retention were yielded regardless of the change of ω2 and ω3, while with the upper mobile phase these two values were sensitively varied according to the different combination of ω2 and ω3. For example, when ω2=147 or 200rpm is used, no stationary phase was retained in the coiled column while ω2=150rpm could retain enough volume of stationary phase for separation. On the other hand, the combined rotation speeds at (ω1, ω2, ω3)=(300, 300, 0rpm) or (300, 0, 300rpm) produced insufficient peak resolution regardless of the choice of the mobile phase apparently due to the lack of rotation speed except at (300, 0, 300rpm) with the upper mobile phase. At lower rotation speed of ω1=300rpm, better peak resolution and stationary phase retention were obtained by the satellite motion (ω3) than by the planetary motion (ω2), or ω3>ω2. The effect of the hydrophobicity of the two-phase solvent systems on the stationary phase retention was further examined using the n

  3. Calixarene-based extraction chromatographic separation of ¹³⁵Cs and ¹³⁷Cs in environmental and waste samples prior to sector field ICP-MS analysis.

    PubMed

    Russell, Ben C; Warwick, Phil E; Croudace, Ian W

    2014-12-02

    Advances in the sensitivities achievable by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) offer the prospect of low-level measurement of shorter and longer lived radionuclides, thus expanding options for environmental and radioactively contaminated land assessment. In ICP-SFMS, the critical requirement for accurate detection is the effective chemical separation of isobaric and polyatomic interferences prior to sample introduction. As instrumental detection limit capability improves, accurate radionuclide determination requires highly effective separation materials that combine high analyte selectivity with subsequent quantitative analyte recovery compatible with ICP-SFMS detection. Two radioactive isotopes measurable by ICP-SFMS are the high yield fission products (135)Cs and (137)Cs that have entered the environment as a result of anthropogenic nuclear activities. ICP-SFMS enables reliable measurement of (135)Cs/(137)Cs ratios, which can be used as a forensic tool in determining the source of nuclear contamination. The critical requirement for accurate detection is the effective removal of isobaric interferences from (135)Ba and (137)Ba prior to measurement. A number of exchange materials can effectively extract Cs; however, non-quantitative elution of Cs makes subsequent ICP-SFMS quantification challenging. A novel extraction chromatographic resin has been developed by dissolving calix[4]arene-bis(tert-octylbenzo-crown-6) (BOBCalixC6) in octan-1-ol and loading onto an Amberchrom CG-71 prefilter resin material. Preparation of the material takes less than 1 h and, at an optimal concentration of 3 M HNO3, shows high selectivity toward Cs, which is effectively eluted in 0.05 M HNO3. The procedure developed shows high Cs selectivity and Ba decontamination from digests of complex matrixes including a saltmarsh sediment contaminated by aqueous discharges from a nuclear fuel reprocessing facility. Repeated tests show the resin can be reused up to

  4. Ion-exclusion chromatographic separations of C1-C6 aliphatic carboxylic acids on a sulfonated styrene-divinylbenzene co-polymer resin column with 5-methylhexanoic acid as eluent.

    PubMed

    Ohta, Kazutoku; Towata, Atsuya; Ohashi, Masayoshi

    2003-05-16

    The application of C7 aliphatic carboxylic acids (heptanoic, 2-methylhexanoic, 5-methylhexanoic and 2,2-dimethyl-n-valeric acids) as eluents in ion-exclusion chromatography with conductimetric detection for C1-C6 aliphatic carboxylic acids (formic, acetic, propionic, isobutyric, butyric, isovaleric, valeric, isocaproic and caproic acids) was carried out using a highly sulfonated styrene-divinylbenzene co-polymer resin (TSKgel SCX) in the H+ form as a stationary phase. When using 0.05 mM sulfuric acid at pH 4.0 as the eluent, peak shapes of hydrophobic carboxylic acids (isovaleric, valeric, isocaproic and caproic acids) were tailed strongly. In contrast, when using 1 mM these C7 carboxylic acids at pH ca. 4 as the eluents, although system peaks (vacant peaks) corresponding to these C7 carboxylic acids appeared, peak shapes of these hydrophobic acids were improved drastically. Excellent simultaneous separation and relatively high sensitive conductimetric detection for these C1-C6 aliphatic carboxylic acids were achieved in 25 min on the TSKgel SCX column (150 x 6 mm I.D.) using 1 mM 5-methylhexanoic acid at pH 4.0 as the eluent.

  5. Core-Shell in Liquid Chromatography: Application for Determining Sulphonamides in Feed and Meat Using Conventional Chromatographic Systems

    PubMed Central

    Armentano, Antonio; Summa, Simona; Magro, Sonia Lo; D’Antini, Pasquale; Palermo, Carmen; Muscarella, Marilena

    2016-01-01

    A C18 column packed with core-shell particles was used for the chromatographic separation of sulphonamides in feed and meat by a conventional high performance liquid chromatography system coupled with a diode array detector. Two analytical methods, already used in our laboratory, have been modified without any changes in the extraction and clean-up steps and in the liquid chromatography instrumentation. Chromatographic conditions applied on a traditional 5-µm column have been optimized on a column packed with 2.6 µm core-shell particles. A binary mobile phase [acetate buffer solution at pH 4.50 and a mixture of methanol acetonitrile 50: 50 (v/v)] was employed in gradient mode at the flow rate of 1.2 mL with an injection volume of 6 µL. These chromatographic conditions allow the separation of 13 sulphonamides with an entire run of 13 minutes. Preliminary studies have been carried out comparing blanks and spiked samples of feed and meat. A good resolution and the absence of interferences were achieved in chromatograms for both matrices. Since no change was made to the sample preparation, the optimized method does not require a complete revalidation and can be used to make routine analysis faster. PMID:28217560

  6. Membrane filtration of Sudan orange G on a cellulose acetate membrane filter for separation-preconcentration and spectrophotometric determination in water, chili powder, chili sauce and tomato sauce samples.

    PubMed

    ALOthman, Zeid A; Unsal, Yunus E; Habila, Mohamed; Shabaka, Azza; Tuzen, Mustafa; Soylak, Mustafa

    2012-08-01

    A simple membrane filtration procedure for separation-enrichment of Sudan orange G is presented. The method is based on the adsorption of Sudan orange G on a cellulose acetate filter and its elution from the membrane with 10 mL of ethanol. Sudan orange G in the eluent was determined by UV-visible spectrophotometry at 388 nm. The effect of analytical conditions, including pH, flow rates and eluent, sample volume, type of membrane for quantitative preconcentration and separation of Sudan orange G were examined. The influences of matrix components on Sudan orange G recoveries were studied. The preconcentration factor was 125. The detection limit was 4.9 μg L(-1). The relative standard deviation was 4.3%. The presented procedure was applied to chili powder, chili sauce, tomato sauce, powdered beverage and water samples.

  7. Stability-indicating chromatographic methods for the determination of some oxicams.

    PubMed

    Taha, Elham Anwer; Salama, Nahla Nour; Abdel Fattah, Laila el-Said

    2004-01-01

    Two sensitive and selective methods were developed for the determination of some oxicams, namely, lornoxicam (LOX), tenoxicam (TEX), and meloxicam (MEX), in the presence of their alkaline degradation products. The first method is based on the thin-layer chromatographic separation of the 3 drugs from their alkaline degradation products, followed by densitometric measurement of the intact drug spots for LOX, TEX, and MEX at 380, 370, and 364 nm, respectively. The developing systems used for separation are ethyl acetate-methanol-26% ammonia (17 + 3 + 0.35, v/v/v) for LOX and TEX and chloroform-n-hexane-96.0% acetic acid (18 + 1 + 1, v/v/v) for MEX. The linear ranges were 0.25-6.0 microg/spot for LOX and TEX and 0.5-10 microg/spot for MEX, with mean recoveries of 99.80 +/- 1.32, 100.57 +/- 1.34, and 100.71 +/- 1.57%, respectively. The second method is based on the liquid chromatographic separation of the 3 drugs from their alkaline degradation products on a reversed-phase C18 column, using mobile phases of methanol-acetonitrile-acetate buffer, pH 4.6 (4.5 + 0.5 + 5.0, v/v/v) for LOX and MEX and methanol-acetonitrile-acetate buffer, pH 4.6 (1.9 + 0.1 + 3.0, v/v/v) for TEX at ambient temperature. Quantification is achieved by UV detection at 280 nm, based on peak area. The linear ranges were 0.5-20 microg/mL for LOX and TEX and 1.25-50 microg/mL for MEX, with mean recoveries of 99.81 +/- 1.01, 98.90 +/- 1.61, and 100.86 +/- 1.55%, respectively. The methods were validated according to guidelines of the International Conference on Harmonization. The developed methods were successfully applied to the determination of LOX, TEX, and MEX in bulk powder, laboratory-prepared mixtures containing different percentages of degradation products, and pharmaceutical dosage forms.

  8. Optimization and validation of high-performance chromatographic condition for simultaneous determination of adapalene and benzoyl peroxide by response surface methodology.

    PubMed

    Chen, Yi-Cheng; Tsai, Pi-Ju; Huang, Yaw-Bin; Wu, Pao-Chu

    2015-01-01

    The aim of this study was to develop a simple and reliable high-performance chromatographic (HPLC) method for simultaneous analysis of adapalene and benzoyl peroxide in pharmaceutical formulation by response surface methodology (RSM). An optimized mobile phase composed of acetonitrile, tetrahydrofuran and water containing 0.1% acetic acid at a ratio of 25:50:25 by volume was successfully predicted by using RSM. An isocratic separation was achieved by using the condition. Furthermore, the analytical method was validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentration. Finally, the method was successfully applied to the analysis of a commercial product.

  9. ION-EXCLUSION CHROMATOGRAPHIC DETERMINATION OF CARBOXYLIC ACIDS USED TO SUPPORT THE MICROBIALLY MEDIATED REDUCTIVE DECHLORINATION OF TETRACHLOROETHENE

    EPA Science Inventory

    An analytical method was developed for the determination of lactic acid, formic acid, acetic acid, propionic acid, and butyric acid in environmental microcosm samples using ion-exclusion chromatography. The chromatographic behavior of various eluents was studied to determine the ...

  10. Gas chromatograph injection system

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.; Henderson, M. E.; Donaldson, R. W., Jr. (Inventor)

    1975-01-01

    An injection system for a gas chromatograph is described which uses a small injector chamber (available in various configurations). The sample is placed in the chamber while the chamber is not under pressure and is not heated, and there is no chance of leakage caused by either pressure or heat. It is injected into the apparatus by changing the position of a valve and heating the chamber, and is volatilized and swept by a carrier gas into the analysis apparatus.

  11. Nano-fabricated size exclusion chromatograph

    NASA Technical Reports Server (NTRS)

    Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; Castillo, L. del; White, V.

    2002-01-01

    This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

  12. Development of a liquid chromatographic method for the simultaneous quantification of curcumin, β-arteether, tetrahydrocurcumin and dihydroartemisinin. Application to lipid-based formulations.

    PubMed

    Memvanga, Patrick B; Mbinze, Jérémie K; Rozet, Eric; Hubert, Philippe; Préat, Véronique; Marini, Roland D

    2014-01-01

    A liquid chromatographic method was developed for the simultaneous separation of curcumin, β-arteether, tetrahydrocurcumin and dihydroartemisinin based on the design of experiments and the design space methodology. The influence of the percentage of organic modifier, flow rate of the mobile phase and column temperature on the analytes separation was investigated. The optimal chromatographic separation was achieved on a C18 column (125mm×4mm, 5μm) using an isocratic elution with a mobile phase consisting of methanol-ammonium acetate (pH 4; 10mM) (80:20, v/v) at a flow rate of 0.45ml/min and a column temperature of 32.5°C. This method was then validated for simultaneous quantification of curcumin and β-arteether contained in lipid-based formulations taking into account the β-expectation tolerance interval for the total error measurement. Finally, the suitability of the proposed liquid chromatographic method for routine analysis of curcumin and β-arteether loaded in lipid-based formulations has been proven.

  13. Chromatographic methods in the study of autism.

    PubMed

    Żurawicz, Ewa; Kałużna-Czaplińska, Joanna; Rynkowski, Jacek

    2013-10-01

    Research into biomarkers of autism is a new means of medical intervention in this disease. Chromatographic techniques, especially coupled with mass spectrometry, are widely used in determination of biomarkers and assessment of effectiveness of autism therapy owing to their sensitivity and selectivity. Among the chromatographic techniques gas chromatography and liquid chromatography, especially high-performance liquid chromatography, have found application in clinical trials. The high-performance liquid chromatography technique allows an analysis of liquid samples with a wide range of molecules, small and large, providing an opportunity to perform advanced assays within a short time frame. Gas chromatography with the appropriate preparation of samples (gaseous and liquid) and a selection of analysis conditions enables the separation of thermally stable, volatile and non-volatile organic substances in short runtimes. The chromatographic techniques that are currently used in metabolic studies in autism are designed to identify abnormalities in three areas: the metabolism of neurotransmitters, nutritional and metabolic status and manifestations of oxidative stress. This review presents a necessary theoretical introduction and examples of applications of chromatographic studies of disorder markers in autism.

  14. Off-line coupling of pressurized liquid extraction and LC/ED for the determination of retinyl acetate and tocopherols in infant formulas.

    PubMed

    Delgado-Zamarreño, M M; Bustamante-Rangel, M; García-Jiménez, M; Sánchez-Pérez, A; Carabias-Martínez, R

    2006-12-15

    An analytical methodology including pressurized liquid extraction (PLE) as sample treatment to isolate retinyl acetate and tocopherols from infant formulas has been developed. The milk extracts were kept at -18 degrees C for 30min and after filtration could be injected directly into the chromatographic system. Thus, a rapid and simple routine control method of these products is possible. The parameters affecting both the extraction process and the liquid chromatography (LC) system were optimized. PLE was performed using one cycle of extraction during a static time of 5min. Methanol was chosen as the extraction solvent for a temperature of 50 degrees C. Chromatographic separation was accomplished using a RP-18 column; the mobile phase used was methanol-water (94:6, v/v) containing 2.5mM acetic acid/sodium acetate buffer. Electrochemical detection in amperometric mode with a glassy carbon electrode at +1100mV was applied. The proposed methodology was successfully used for the determination of retinyl acetate, delta-tocopherol, (beta+gamma)-tocopherol and alpha-tocopherol in different infant formulas. The analytes were evaluated in the same chemical form present in the samples. Recoveries were between 92 and 106%. A certified reference material of milk powder was also analyzed.

  15. Hand-held multiple system gas chromatograph

    DOEpatents

    Yu, Conrad M.

    2001-01-01

    A multiple parallel hand-held gas chromatograph (GC) system which includes several independent GCs. Each independent GC has its own injector, separation column, detector and oven and the GCs are mounted in a light weight hand-held assembly. Each GC operates independently and simultaneously. Because of different coatings in different separation columns, different retention times for the same gas will be measured. Thus, for a GC system with multiple parallel GCs, the system can measure, in a short period, different retention times and provide a cross-reference in the determination of the measured gas and to become a two-dimensional system for direct field use.

  16. The feed forward neural network model for liquid-liquid extraction and separation of cobalt (II) from sodium acetate media using cyanex 272

    NASA Astrophysics Data System (ADS)

    Sudibyo, Aji, B. B.; Priyanto, S.

    2017-03-01

    Cobalt is one of the precious ferromagnetic metals, which widely used in the preparation of magnetic, wear-resistant and high-strength alloys. This metal was not found naturally in single metal form but is found as impurities in nickel or copper ore. The extraction process is one of the methods to separate cobalt from its impurities. However, this process needs an expensive organic solution. In practice, changing the composition of chemicals composition in extraction process always affect at a high cost. Therefore, the development of the artificial neural network (ANN) model to model the cobalt extraction process can serve as an important tool for predicting and investigating the optimum production for the cobalt extraction without the need to run the actual experiment. Hence, the development of the ANN model of cobalt extraction model is essential to simulate the process, which can lead to high yields of cobalt production. In this work a selected optimum multiple-input-single-output (MISO) model of feed forward neural network (FFNN) was used to predict the percentage of cobalt extraction. MISO FFNN with 20, 30 and 50 hidden nodes were used to simulate cobalt extraction process. The simulation results achieved was compared with data available in the literature. The results show that MISO FFNN with 50 hidden nodes has the best performance. The optimum result of MISO FFNN then exported to Simulink model in Matlab environment, hence make it easy to use in predicting and investigating for the optimum production of the cobalt extraction.

  17. Chromatographic purification of highly active yeast ribosomes.

    PubMed

    Meskauskas, Arturas; Leshin, Jonathan A; Dinman, Jonathan D

    2011-10-24

    Eukaryotic ribosomes are much more labile as compared to their eubacterial and archael counterparts, thus posing a significant challenge to researchers. Particularly troublesome is the fact that lysis of cells releases a large number of proteases and nucleases which can degrade ribosomes. Thus, it is important to separate ribosomes from these enzymes as quickly as possible. Unfortunately, conventional differential ultracentrifugation methods leaves ribosomes exposed to these enzymes for unacceptably long periods of time, impacting their structural integrity and functionality. To address this problem, we utilize a chromatographic method using a cysteine charged Sulfolink resin. This simple and rapid application significantly reduces co-purifying proteolytic and nucleolytic activities, producing high yields of intact, highly biochemically active yeast ribosomes. We suggest that this method should also be applicable to mammalian ribosomes. The simplicity of the method, and the enhanced purity and activity of chromatographically purified ribosome represents a significant technical advancement for the study of eukaryotic ribosomes.

  18. Modified gas chromatographic/mass spectrometric method for determination of daminozide in high protein food products.

    PubMed

    Faughnan, K T; Woodruff, M A

    1991-01-01

    A modified version of the Conditt and Baumgardner gas chromatographic/mass spectroscopic (GC/MS) method for determination of daminozide in peanut butter and raw peanuts is described. Daminozide in the food product is hydrolyzed to unsymmetrical dimethylhydrazine (UDMH) by sodium hydroxide digestion. The generated UDMH is distilled from the food matrix and captured by reaction with salicylaldehyde in a condensation trap. Resulting high pH distillates generated by peanuts and peanut products are adjusted back to a pH of 5-6 through addition of glacial acetic acid. After thermal incubation and extraction into methylene chloride, salicylaldehyde dimethylhydrazone is separated from interferences by capillary GC and quantitated by MS using the selective ion monitoring (SIM) mode. Quantitation of daminozide is based on the ratio of the salicylaldehyde dimethylhydrazone molecular ion (m/z 164) to the molecular ion (m/z 153) of the internal standard, 4-nitroanisole. Confirmation of daminozide identity is determined by relative intensity of the m/z 164 ion to the m/z 120 (C7H4ON) ion. Improved m/z 164 ion intensity and reduction of neighboring interferences due to acetic acid treatment permitted a daminozide detection limit of 0.005 ppm in a 50 g sample and an associated 0.02 ppm limit of quantitation. This modification is specific for high protein samples that generate high pH distillates such as peanuts and peanut products and is not specifically intended for analysis of low protein samples.

  19. Column performance study of different variants of liquid chromatographic technique: an application on pharmaceutical ternary mixtures containing tetryzoline.

    PubMed

    Salem, Hesham; Hassan, Nagiba Y; Lotfy, Hayam M; Saleh, Sarah S

    2015-01-01

    High-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and rapid resolution liquid chromatographic (RRLC) methods have been developed and validated for the separation and quantitation of both or either of two ternary mixtures present in ophthalmic solutions. The first mixture contains chloramphenicol, dexamethasone sodium phosphate and tetryzoline HCl (TZH); while the second one contains ofloxacin, prednisolone acetate and TZH. Both preparations contain benzalkonium chloride as a preservative. The columns used were a HPLC column (C18 5 µm particle size), a RRLC column (C18 2.6 µm particle size) and a UPLC column (C18 1.7 µm particle size). A comparative study was conducted to illustrate the effect of the change in column particle size and dimensions on the other chromatographic conditions, backpressure and the separation of both ternary mixtures. The methods were validated as per ICH guidelines where accuracy, repeatability, interday precision and robustness were found to be within the acceptable limits. The RRLC column provided shorter run time and better resolution than HPLC, while the UPLC column gave the shortest run time for all columns. The RRLC column resulted in minimum backpressure, so it could be used with any HPLC instrument, which makes the method more practical and economic. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed.

  20. Application of Analytical Quality by Design concept for bilastine and its degradation impurities determination by hydrophilic interaction liquid chromatographic method.

    PubMed

    Terzić, Jelena; Popović, Igor; Stajić, Ana; Tumpa, Anja; Jančić-Stojanović, Biljana

    2016-06-05

    This paper deals with the development of hydrophilic interaction liquid chromatographic (HILIC) method for the analysis of bilastine and its degradation impurities following Analytical Quality by Design approach. It is the first time that the method for bilastine and its impurities is proposed. The main objective was to identify the conditions where an adequate separation in minimal analysis duration could be achieved within a robust region. Critical process parameters which have the most influence on method performance were defined as acetonitrile content in the mobile phase, pH of the aqueous phase and ammonium acetate concentration in the aqueous phase. Box-Behnken design was applied for establishing a relationship between critical process parameters and critical quality attributes. The defined mathematical models and Monte Carlo simulations were used to identify the design space. Fractional factorial design was applied for experimental robustness testing and the method is validated to verify the adequacy of selected optimal conditions: the analytical column Luna(®) HILIC (100mm×4.6mm, 5μm particle size); mobile phase consisted of acetonitrile-aqueous phase (50mM ammonium acetate, pH adjusted to 5.3 with glacial acetic acid) (90.5:9.5, v/v); column temperature 30°C, mobile phase flow rate 1mLmin(-1), wavelength of detection 275nm.

  1. A Gas Chromatographic Method for the Determination of Aldose and Uronic Acid Constituents of Plant Cell Wall Polysaccharides 1

    PubMed Central

    Jones, Thomas M.; Albersheim, Peter

    1972-01-01

    A major problem in determining the composition of plant cell wall polysaccharides has been the lack of a suitable method for accurately determining the amounts of galacturonic and glucuronic acids in such polymers. A gas chromatographic method for aldose analysis has been extended to include uronic acids. Cell wall polysaccharides are depolymerized by acid hydrolysis followed by treatment with a mixture of fungal polysaccharide-degrading enzymes. The aldoses and uronic acids released by this treatment are then reduced with NaBH4 to alditols and aldonic acids, respectively. The aldonic acids are separated from the alditols with Dowex-1 (acetate form) ion exchange resin, which binds the aldonic acids. The alditols, which do not bind, are washed from the resin and then acetylated with acetic anhydride to form the alditol acetate derivatives. The aldonic acids are eluted from the resin with HCl. After the resin has been removed, the HCl solution of the aldonic acids is evaporated to dryness, converting the aldonic acids to aldonolactones. The aldonolactones are reduced with NaBH4 to the corresponding alditols, dried and acetylated. The resulting alditol acetate mixtures produced from the aldoses and those from the uronic acids are analyzed separately by gas chromatography. This technique has been used to determine the changes in composition of Red Kidney bean (Phaseolus vulgaris) hypocotyl cell walls during growth, and to compare the cell wall polysaccharide compositions of several parts of bean plants. Galacturonic acid is found to be a major component of all the cell wall polysaccharides examined. PMID:16658086

  2. Rapid ion-pair liquid chromatographic method for the determination of fenbendazole marker residue in fermented dairy products.

    PubMed

    Vousdouka, Venetia I; Papapanagiotou, Elias P; Angelidis, Apostolos S; Fletouris, Dimitrios J

    2017-04-15

    A simple, rapid and sensitive liquid chromatographic method that allows for the quantitative determination of fenbendazole residues in fermented dairy products is described. Samples were extracted with a mixture of acetonitrile-phosphoric acid and the extracts were defatted with hexane to be further partitioned into ethyl acetate. The organic layer was evaporated to dryness and the residue was reconstituted in mobile phase. Separation of fenbendazole and its sulphoxide, sulphone, and p-hydroxylated metabolites was carried out isocratically with a mobile phase containing both positively and negatively charged pairing ions. Overall recoveries ranged from 79.8 to 88.8%, while precision data, based on within and between days variations, suggested an overall relative standard deviation of 6.3-11.0%. The detection and quantification limits were lower than 9 and 21μg/kg, respectively. The method has been successfully applied to quantitate fenbendazole residues in Feta cheese and yoghurt made from spiked and incurred ovine milk.

  3. Quantifying process tradeoffs in the operation of chromatographic sequences.

    PubMed

    Ngiam, Sheau-Huey; Bracewell, Daniel G; Zhou, Yuhong; Titchener-Hooker, Nigel J

    2003-01-01

    A method for the rapid representation of key process tradeoffs that need to be made during the analysis of chromatographic sequences has been proposed. It involves the construction of fractionation and maximum purification factor versus yield diagrams, which can be completed easily on the basis of chromatographic data. The output of the framework developed reflects the degree of tradeoff between levels of yield and purity and provides a fast and precise prediction of the sample fraction collection strategy needed to meet a desired process specification. The usefulness of this approach for the purposes of product purification and contaminant removal in a single chromatographic step has been successfully demonstrated in an earlier paper and it is now extended by application to a chromatographic sequence: the separation of a hypothetical three-component protein system by hydrophobic interaction chromatography (HIC) followed by size exclusion chromatography (SEC). The HIC operation has a strong impact upon the subsequent SEC step. The studies show how the analysis of performance in such a chromatographic sequence can be carried out easily and in a straightforward fashion using the fractionation diagram approach. The methodology proposed serves as a useful tool for identifying the process tradeoffs that must be made during operation of a sequence of chromatographic steps and indicates the impact on further processing of the cut-point decisions that are made.

  4. Gas chromatograph-mass spectrometer (GC/MS) system for quantitative analysis of reactive chemical compounds

    DOEpatents

    Grindstaff, Quirinus G.

    1992-01-01

    Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.

  5. Development and Validation of an RP-HPLC Method for Quantitative Estimation of Eslicarbazepine Acetate in Bulk Drug and Tablets.

    PubMed

    Singh, M; Kumar, L; Arora, P; Mathur, S C; Saini, P K; Singh, R M; Singh, G N

    2013-11-01

    A convenient, simple, accurate, precise and reproducible RP-HPLC method was developed and validated for the estimation of eslicarbazepine acetate in bulk drug and tablet dosage form. Objective was achieved under optimised chromatographic conditions on Dionex RP-HPLC system with Dionex C18 column (250×4.6 mm, 5 μm particle size) using mobile phase composed of methanol and ammonium acetate (0.005 M) in the ratio of 70:30 v/v. The separation was achieved using an isocratic elution method with a flow rate of 1.0 ml/ min at room temperature. The effluent was monitored at 230 nm using diode array detector. The retention time of eslicarbazepine acetate is found to be 4.9 min and the standard calibration plot was linear over a concentration range of 10-90 μg/ml with r(2)=0.9995. The limit of detection and quantification were found to be 3.144 and 9.52 μg/ml, respectively. The amount of eslicarbazepine acetate in bulk and tablet dosage form was found to be 99.19 and 97.88%, respectively. The method was validated statistically using the percent relative standard deviation and the values are found to be within the limits. The recovery studies were performed and the percentage recoveries were found to be 98.33± 0.5%.

  6. Rayleigh light scattering detection of three α1-adrenoceptor antagonists coupled with high performance liquid chromatograph

    NASA Astrophysics Data System (ADS)

    Li, Ai Ping; Peng, Huanjun; Peng, Jing Dong; Zhou, Ming Qiong; Zhang, Jing

    2015-08-01

    Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 μm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH = 3.0) at the flow rate of 0.7 mL min-1. The RLS signal was monitored at λex = λem = 354 nm. A limit of detection (LOD) of 0.065-0.70 μg L-1 was reached and a linear range was found between peak height and concentration in the range of 0.75-15 μg L-1 for doxazosin mesylate (DOX), 0.075-3.0 μg L-1 for prazosin hydrochloride (PRH), and 0.25-5 μg L-1 for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.

  7. Different Spectrophotometric and Chromatographic Methods for Determination of Mepivacaine and Its Toxic Impurity.

    PubMed

    Abdelwahab, Nada S; Fared, Nehal F; Elagawany, Mohamed; Abdelmomen, Esraa H

    2017-02-21

    Stability-indicating spectrophotometric, TLC-densitometric, and ultra-performance LC (UPLC) methods were developed forthe determination of mepivacaine HCl (MEP) in the presence of its toxic impurity, 2,6-dimethylanaline (DMA). Different spectrophotometric methods were developed for the determination of MEP and DMA. In a dual-wavelength method combined with direct spectrophotometric measurement, the absorbance difference between 221.4 and 240 nm was used for MEP measurements, whereas the absorbance at 283 nm was used for measuring DMA in the binary mixture. In the second-derivative method, amplitudes at 272.2 and 232.6 nm were recorded and used for the determination of MEP and DMA, respectively. The developed TLC-densitometric method depended on chromatographic separation using silica gel 60 F254 TLC plates as a stationary phase and methanol-water-acetic acid (9 + 1 + 0.1, v/v/v) as a developing system, with UV scanning at 230 nm. The developed UPLC method depended on separation using a C18 column (250 × 4.6 mm id, 5 μm particle size) as a stationary phase and acetonitrile-water (40 + 60, v/v; pH 4 with phosphoric acid) as a mobile phase at a flow rate of 0.4 mL/min, with UV detection at 215 nm. The chromatographic run time was approximately 1 min. The proposed methods were validated with respect to International Conference on Harmonization guidelines regarding precision, accuracy, ruggedness, robustness, and specificity.

  8. Effect of chromatographic conditions on retention behavior and system efficiency for HPTLC of selected psychotropic drugs on chemically bonded stationary phases.

    PubMed

    Petruczynik, Anna; Wróblewski, Karol; Waksmundzka-Hajnos, Monika

    2015-01-01

    Selected psychotropic drug standards have been chromatographed on RP18, CN and diol layers with a variety of aqueous and nonaqueous mobile phases. The effect of buffers at acidic or basic pH, acetic acid, ammonia and diethylamine (DEA) in aqueous mobile phases on retention, efficiency and peak symmetry was examined. Improved peak symmetry and separation selectivity for investigated compounds were observed when ammonia or DEA were used as mobile phase additives. The effect of diethylamine concentration in aqueous eluents on retention, peak symmetry and theoretical plate number obtained on CN plates was also investigated. Because of the strong retention of these basic drugs on stationary phases bonded on silica matrix, nonaqueous eluents containing medium polar diluents, strongly polar modifiers and silanol blockers (ammonia or diethylamine) were applied. Aqueous and nonaqueous eluent systems with the best selectivity and efficiency were used for separate psychotropic drug standards' mixture on CN layer by 2D TLC.

  9. Nanofluidic Size-Exclusion Chromatograph

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Svehla, Danielle; Grunthaner, Frank; Feldman, Jason; Shakkottai, P.

    2004-01-01

    Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

  10. On the ion chromatographic determination of S(IV)

    NASA Astrophysics Data System (ADS)

    Dasgupta, Purnendu K.

    Ion Chromatographie determination of S(IV) is described with special reference to the determination of SO 2(g) and/or aerosol S(IV) along with chloride, nitrate and sulfate in particulate matter. A method is presented for the baseline separation of the above species. The Chromatographic behavior of hydroxymethanesulfonate under various eluent conditions is discussed.

  11. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everwhere else around the annulus. The rotation of the sorbent bed causes the separation components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m0-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory.

  12. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory. 17 references, 9 figures, 1 table.

  13. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory. 9 figures, 1 table.

  14. Transesterification of propylene glycol methyl ether in chromatographic reactors using anion exchange resin as a catalyst.

    PubMed

    Oh, Jungmin; Sreedhar, Balamurali; Donaldson, Megan E; Frank, Timothy C; Schultz, Alfred K; Bommarius, Andreas S; Kawajiri, Yoshiaki

    2016-09-30

    Reactive chromatography using an anion exchange resin is proposed for a transesterification reaction of propylene glycol methyl ether (DOWANOL™ PM) with ethyl acetate to produce propylene glycol methyl ether acetate (DOWANOL™ PMA). This reaction is studied in batch and chromatographic reactors catalyzed by an anion exchange resin. Several anion exchange resins are tested and compared based on the performance of resin as an adsorbent and a catalyst. A chromatographic column is packed with a selected catalyst, AMBERLITE™ IRA904, and both reaction and chromatographic elution are studied at different temperatures and feed concentrations. The resulting chromatograms are fitted to a mathematical model to obtain adsorption equilibrium and reaction kinetic parameters by the inverse method. Compared to esterification investigated in a previous study, transesterification has advantages such as a higher conversion at lower temperature and easy removal of the byproduct which may lead to higher productivity. Deactivation of anion exchange resins is observed and potential solutions are suggested.

  15. High performance hand-held gas chromatograph

    SciTech Connect

    Yu, C.M.

    1998-04-28

    The Microtechnology Center of Lawrence Livermore National Laboratory has developed a high performance hand-held, real time detection gas chromatograph (HHGC) by Micro-Electro-Mechanical-System (MEMS) technology. The total weight of this hand-held gas chromatograph is about five lbs., with a physical size of 8{close_quotes} x 5{close_quotes} x 3{close_quotes} including carrier gas and battery. It consumes about 12 watts of electrical power with a response time on the order of one to two minutes. This HHGC has an average effective theoretical plate of about 40k. Presently, its sensitivity is limited by its thermal sensitive detector at PPM. Like a conventional G.C., this HHGC consists mainly of three major components: (1) the sample injector, (2) the column, and (3) the detector with related electronics. The present HHGC injector is a modified version of the conventional injector. Its separation column is fabricated completely on silicon wafers by means of MEMS technology. This separation column has a circular cross section with a diameter of 100 pm. The detector developed for this hand-held GC is a thermal conductivity detector fabricated on a silicon nitride window by MEMS technology. A normal Wheatstone bridge is used. The signal is fed into a PC and displayed through LabView software.

  16. A model for the shuttle motions of puerarin and daidzin inside the cavity of β-cyclodextrin in aqueous acetic acid: insights from molecular dynamics simulations.

    PubMed

    Zhang, Haiyang; Feng, Wei; Li, Cong; Lv, Yongqin; Tan, Tianwei

    2012-01-01

    Acetic acid acts as one component of the mobile phase to influence separation of puerarin from daidzin when using β-cyclodextrin-substituted media. In this work considering an explicit acetic acid solution, host-guest complexes of β-cyclodextrin (β-CD) with puerarin and daidzin were investigated by molecular dynamics simulations. Computational results indicate different shuttle motions of puerarin and daidzin inside the cavity of β-CD. A model detailing the shuttle motion was constructed, and the relationships between shuttle depth and guest rotation angles, hydrogen bonds, and host-guest interaction energies were analyzed. The results can be used to explain the chromatographic retention mechanisms of puerarin and daidzin with β-CD, and to explore the complexity of host-guest interactions involving β-CD.

  17. Gas chromatographic methods for determination of gamma-BHC in technical emulsifiable concentrates and water-dispersible powder formulations and in lindane shampoo and lotion: collaborative study.

    PubMed

    Miles, J W; Mount, D L; Beckmann, T J; Carrigan, S K; Galoux, I M; Hitos, P; Hodge, M C; Kissler, K; Martijn, A; Sanchez-Rasero, F

    1984-01-01

    Although the gas chromatographic separation of the isomers of BHC was demonstrated two decades ago, the present AOAC method of analysis of BHC for gamma-isomer (lindane) content is based on a separation carried out on a liquid chromatographic partition column. A method of analysis has been developed that uses an OV-210 column for separation of the gamma-isomer from the other isomers and impurities in technical BHC. Di-n-propyl phthalate was chosen as an internal standard. The same system allows quantitation of lindane in lotion and shampoo after these products are extracted with ethyl acetate-isooctane (1 + 4). The analytical methods were subjected to a collaborative trial with 10 laboratories. The coefficient of variation for technical BHC was 2.83%. For the water-dispersible powder and emulsifiable concentrate, the coefficients of variation were 2.89% and 4.62%, respectively. Coefficients of variation for 1% lindane lotion and shampoo were 4.36% and 11.92%, respectively. The method has been adopted official first action.

  18. DEVELOPMENT AND VALIDATION OF AN ION CHROMATOGRAPHIC METHOD FOR DETERMINING PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    A method has been developed for the determination of perchlorate in fertilizers. Materials are leached with deionized water to dissolve any soluble perchlorate compounds. Ion chromatographic separation is followed by suppressed conductivity for detection. Perchlorate is retained ...

  19. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  20. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, Don D.

    1985-01-01

    A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  1. Chromatographic separation of reaction products from the choline acetyltransferase and carnitine acetyltransferase assay: differential ChAT and CrAT activity in brain extracts from Alzheimer's disease versus controls.

    PubMed

    Bailey, Jason A; Lahiri, Debomoy K

    2012-08-01

    Choline acetyltransferase (ChAT) catalyzes the reaction between choline and acetylcoenzyme A (AcCoA) to form acetylcholine (ACh) in nerve terminals. ACh metabolism has implications in numerous aspects of physiology and varied disease states, such as Alzheimer's disease. Therefore a specific, sensitive, and reliable method for detecting ChAT enzyme activity is of great utility in a number of situations. Using an existing radionuclide-based enzyme activity assay, we have observed detectable ChAT signals from non-cholinergic cells, suggesting a contaminant in the assay producing an artifactual signal. Previous reports have suggested that L-acetylcarnitine (LAC) contaminates many assays of ChAT activity, because of difficulties in separating LAC from ACh by organic extraction. To determine the source of this hypothesized artifact and to rectify the problem, we have developed a paper chromatography-based assay for the detection of acetylcholine and other contaminating reaction products of this assay, including LAC. Our first goal was to develop a simple and economical method for resolving and verifying the identities of various reaction products or contaminants that could be performed in most laboratories without specialized equipment. Our second goal was to apply this separation method in postmortem human brain tissue samples. Our assay successfully detected several contaminants, especially in assays using brain tissue, and allowed the separation of the intended ACh product from these contaminants. We further demonstrate that this assay can be used to measure carnitine acetyltransferase (CrAT) activity in the same samples, and assays comparing ChAT and CrAT show that CrAT is highly active in neuronal tissues and in neuronal cell cultures relative to ChAT. Thus, the simple chromatography-based assay we describe allows the measurement of specific reaction products separated from contaminants using commonly available and inexpensive materials. Further, we show that Ch

  2. Ion-exchange chromatographic analysis of peroxynitric acid.

    PubMed

    Nakashima, Yoichi; Ikawa, Satoshi; Tani, Atsushi; Kitano, Katsuhisa

    2016-01-29

    Ion-exchange chromatographic analysis of peroxynitric acid (O2NOOH) was performed by combining an acidic eluate with an UV-vis detector and immersing the separation column in an ice-water bath. The decomposition behavior of peroxynitric acid in the solution was also studied using this system. The fraction for the peroxynitric acid peak was collected. Ion-exchange chromatographic analysis of this fraction, after standing at room temperature for 24h, showed that the decomposition products were mainly nitrate ions with a very small amount of nitrous acid. The peroxynitric acid peak area correlated perfectly with the total amount of decomposition products. The ion-exchange chromatographic isolation allowed us to evaluate the molar extinction coefficient of peroxynitric acid precisely in a wider wavelength range than previous reports. The value decreases monotonically from 1729±26M(-1)cm(-1) at 200nm to 12.0±0.5M(-1)cm(-1) at 290nm.

  3. Chromatographic extraction with di(2-ethylhexyl)orthophosphoric acid for production and purification of promethium-147

    DOEpatents

    Boll, Rose A [Knoxville, TN

    2008-10-14

    A method of producing and purifying promethium-147 including the steps of: irradiating a target material including neodymium-146 with neutrons to produce promethium-147 within the irradiated target material; dissolving the irradiated target material to form an acidic solution; loading the acidic solution onto a chromatographic separation apparatus containing HDEHP; and eluting the apparatus to chromatographically separate the promethium-147 from the neodymium-146.

  4. New small-scale cross-axis coil planet centrifuge. The design of the apparatus and its application to counter-current chromatographic separation of proteins with aqueous-aqueous polymer phase systems.

    PubMed

    Shinomiya, Kazufusa; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2006-02-03

    The cross-axis coil planet centrifuge (X-axis CPC) is useful for partitioning macromolecules with aqueous-aqueous polymer phase systems. The floor model we have built with a pair of separation columns had some shortcomings such as requirement of large space, short life of the flow tubes, and difficulty in installing columns. In order to improve the partition efficiency and the utility of counter-current chromatography (CCC), a new small-scale X-axis CPC was designed and fabricated in our laboratory. The down-sizing of the apparatus was done by reducing the scale to about 1/2 of our original model of X-1.5L type with several improvements. Performance of the apparatus was evaluated on protein separation using an aqueous-aqueous polymer phase system composed of polyethylene glycol 1000 and dibasic potassium phosphate with four multilayer coiled columns. A series of experiments revealed that the combination of right- and left-handed coils produced the best partition efficiencies for both lower and upper mobile phases by selecting the revolution direction. The overall results indicate that the head-tail elution mode substantially affects to the peak resolution and stationary phase retention. This new X-axis CPC would be useful for the separation of various kinds of biologically active compounds.

  5. Simultaneous separation of hydrophobic and hydrophilic peptides with a silica hydride stationary phase using aqueous normal phase conditions.

    PubMed

    Boysen, Reinhard I; Yang, Yuanzhong; Chowdhury, Jamil; Matyska, Maria T; Pesek, Joseph J; Hearn, Milton T W

    2011-11-04

    The application of a silica hydride modified stationary phase with low organic loading has been investigated as a new type of chromatographic material suitable for the separation and analysis of peptides with electrospray ionization mass spectrometric detection. Retention maps were established to delineate the chromatographic characteristics of a series of peptides with physical properties ranging from strongly hydrophobic to very hydrophilic and encompassing a broad range of pI values (pI 5.5-9.4). The effects of low concentrations of two additives (formic acid and acetic acid) in the mobile phase were also investigated with respect to their contribution to separation selectivity and retention under comparable conditions. Significantly, strong retention of both the hydrophobic and the hydrophilic peptides was observed when high-organic low-aqueous mobile phases were employed, thus providing a new avenue to achieve high resolution peptide separations. For example, simultaneous separation of hydrophobic and hydrophilic peptides was achieved under aqueous normal phase (ANP) chromatographic conditions with linear gradient elution procedures in a single run, whilst further gradient optimization enabled improved peak efficiencies of the more strongly retained hydrophobic and hydrophilic peptides.

  6. Capillary electrochromatography with monolithic silica column: I. Preparation of silica monoliths having surface-bound octadecyl moieties and their chromatographic characterization and applications to the separation of neutral and charged species.

    PubMed

    Allen, Darin; El Rassi, Ziad

    2003-01-01

    Monolithic silica columns with surface-bound octadecyl (C18) moieties have been prepared by a sol-gel process in 100 microm ID fused-silica capillaries for reversed-phase capillary electrochromatography of neutral and charged species. The reaction conditions for the preparation of the C18-silica monoliths were optimized for maximum surface coverage with octadecyl moieties in order to maximize retention and selectivity toward neutral and charged solutes with a sufficiently strong electroosmotic flow (> 2 mm/s) to yield rapid analysis time. Furthermore, the effect of the pore-tailoring process on the silica monoliths was performed over a wide range of treatment time with 0.010 M ammonium hydroxide solution in order to determine the optimum time and conditions that yield mesopores of narrow pore size distribution that result in high separation efficiency. Under optimum column fabrication conditions and optimum mobile phase composition and flow velocity, the average separation efficiency reached 160 000 plates/m, a value comparable to that obtained on columns packed with 3 microm C18-silica particles with the advantages of high permeability and virtually no bubble formation. The optimized monolithic C18-silica columns were evaluated for their retention properties toward neutral and charged analytes over a wide range of mobile phase compositions. A series of dimensionless retention parameters were evaluated and correlated to solute polarity and electromigration property. A dimensionless mobility modulus was introduced to describe charged solute migration and interaction behavior with the monolithic C18-silica in a counterflow regime during capillary electrochromatography (CEC )separations. The mobility moduli correlated well with the solute hydrophobic character and its charge-to-mass ratio.

  7. Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography--diode array detection data and second order algorithms.

    PubMed

    Culzoni, María J; Schenone, Agustina V; Llamas, Natalia E; Garrido, Mariano; Di Nezio, Maria S; Band, Beatriz S Fernández; Goicoechea, Héctor C

    2009-10-16

    A fast chromatographic methodology is presented for the analysis of three synthetic dyes in non-alcoholic beverages: amaranth (E123), sunset yellow FCF (E110) and tartrazine (E102). Seven soft drinks (purchased from a local supermarket) were homogenized, filtered and injected into the chromatographic system. Second order data were obtained by a rapid LC separation and DAD detection. A comparative study of the performance of two second order algorithms (MCR-ALS and U-PLS/RBL) applied to model the data, is presented. Interestingly, the data present time shift between different chromatograms and cannot be conveniently corrected to determine the above-mentioned dyes in beverage samples. This fact originates the lack of trilinearity that cannot be conveniently pre-processed and can hardly be modelled by using U-PLS/RBL algorithm. On the contrary, MCR-ALS has shown to be an excellent tool for modelling this kind of data allowing to reach acceptable figures of merit. Recovery values ranged between 97% and 105% when analyzing artificial and real samples were indicative of the good performance of the method. In contrast with the complete separation, which consumes 10 mL of methanol and 3 mL of 0.08 mol L(-1) ammonium acetate, the proposed fast chromatography method requires only 0.46 mL of methanol and 1.54 mL of 0.08 mol L(-1) ammonium acetate. Consequently, analysis time could be reduced up to 14.2% of the necessary time to perform the complete separation allowing saving both solvents and time, which are related to a reduction of both the costs per analysis and environmental impact.

  8. Rapid extraction and reverse phase-liquid chromatographic separation of mercury(II) and methylmercury in fish samples with inductively coupled plasma mass spectrometric detection applying oxygen addition into plasma.

    PubMed

    Döker, Serhat; Boşgelmez, İffet İpek

    2015-10-01

    A simple and sensitive procedure was developed for extraction and speciation of mercury in fish. Species separation was accomplished with reverse phase-high performance liquid chromatography (HPLC) hyphenated to inductively coupled plasma mass spectrometry (ICP-MS). Oxygen addition into plasma allowed use of organic-rich mobile phase, achieving species separation in 4 min. Mercury species extraction was achieved by microwave exposure for 2 min at mild conditions (60°C, pH 2.0), avoiding necessity of neutralizing sample prior to injection in HPLC, and reducing number of sample preparation steps, analytical source of errors and inter conversion of species. Limit of detection for entire procedure was found to be 0.2 and 0.1 ng g(-1) for mercuric ion and methylmercury, respectively. The method was applied to certified reference materials (TORT-2 and DORM-2) and commercialized fish samples (Mullus barbatus, Sparus aurata, Trachurus mediterraneus, Mugil soiuy, Dicentrarchus labrax, and Pomatomus saltatrix) from Black Sea.

  9. A validated liquid chromatographic method for the determination of polycyclic aromatic hydrocarbons in honey after homogeneous liquid-liquid extraction using hydrophilic acetonitrile and sodium chloride as mass separating agent.

    PubMed

    Koltsakidou, Anastasia; Zacharis, Constantinos K; Fytianos, Konstantinos

    2015-01-16

    In the present report, a simple and cost-effective method for the determination of twelve US EPA priority polycyclic aromatic hydrocarbons (PAHs) in honey samples after salting-assisted liquid-liquid extraction and UHPLC with fluorescence detection is proposed. The sample treatment is based on the usage of hydrophilic acetonitrile as extraction solvent and its phase separation under high salinity conditions. Due to the high sugar content of the samples the phase separation is promoted effortlessly. Several parameters affecting the extraction efficiency and method sensitivity including the concentration of the honey samples, the type and volume of the extraction solvent, the type and quantity of the inorganic salt, extraction time and centrifugation time was systematically investigated. The method was validated in-house according to the Commission Decision 2002/657/EC guidelines. The limit of detection (LOD) of the method lay between 0.02 and 0.04ngmL(-1) (corresponding to 0.08 and 0.16ngg(-1)) which are close to the quality criteria established by European Regulation (EC) 836/2011 concerning the PAHs in foodstuffs. The mean analytical bias (expressed as relative recoveries) in all spiking levels was acceptable being in the range of 54-118% while the relative standard deviation (RSD) was lower than 19%. The proposed method has been satisfactorily applied for the analysis of the selected PAHs residues in various honey samples obtained from Greek region.

  10. Preparative separation of flavonoid glycosides in leaves extract of Ampelopsis grossedentata using high-speed counter-current chromatography.

    PubMed

    Du, Qizhen; Chen, Ping; Jerz, Gerold; Winterhalter, Peter

    2004-06-18

    Preparative separation of flavonoid glycosides in leaves extract of Ampelopsis grossedentata was conducted using high-speed counter-current chromatograph (HSCCC) with a solvent system composed of n-hexane-ethyl acetate-methanol-water (1:6:1.5:7.5, v/v). In a single operation, 28 mg of 5,7-dihydroxy-3',4'-trihydroxyflavone-3-O-6''-rhamnose and 18 mg of 5,7-dihydroxy-3',4'-dihydroxyflavone-3-O-6''-rhamnose was obtained from 150 mg of the extract. The chemical structure of the two compounds was elucidated by electrospray ionization (EIS) MS and NMR.

  11. Expression of Acetate Permease-like (apl) Genes in Subsurface Communities of Geobacter Species Under Fluctuating Acetate Concentrations

    SciTech Connect

    Elifantz, H; N'Guessan, A L; Mouser, Paula; Williams, Kenneth H; Wilkins, Michael J; Risso, Carla; Holmes, Dawn; Long, Philip E; Lovley, Derek R

    2010-09-01

    The addition of acetate to uranium-contaminated aquifers in order to stimulate the growth and activity of Geobacter species that reduce uranium is a promising in situ bioremediation option. Optimizing this bioremediation strategy requires that sufficient acetate be added to promote Geobacter species growth. We hypothesized that under acetate-limiting conditions, subsurface Geobacter species would increase the expression of either putative acetate symporters genes (aplI and aplII). Acetate was added to a uranium-contaminated aquifer (Rifle, CO) in two continuous amendments separated by 5 days of groundwater flush to create changing acetate concentrations. While the expression of aplI in monitoring well D04 (high acetate) weakly correlated with the acetate concentration over time, the transcript levels for this gene were relatively constant in well D08 (low acetate). At the lowest acetate concentrations during the groundwater flush, the transcript levels of aplII were the highest. The expression of aplII decreased 2–10-fold upon acetate reintroduction. However, the overall instability of acetate concentrations throughout the experiment could not support a robust conclusion regarding the role of apl genes in response to acetate limitation under field conditions, in contrast to previous chemostat studies, suggesting that the function of a microbial community cannot be inferred based on lab experiments alone.

  12. Expression of acetate permease-like (apl) genes in subsurface communities of Geobacter species under fluctuating acetate concentrations

    SciTech Connect

    Elifantz, H.; N'Guessan, L.A.; Mouser, P.J.; Williams, K H.; Wilkins, M J.; Risso, C.; Holmes, D.E.; Long, P.E.; Lovley, D.R.

    2010-03-01

    The addition of acetate to uranium-contaminated aquifers in order to stimulate the growth and activity of Geobacter species that reduce uranium is a promising in situ bioremediation option. Optimizing this bioremediation strategy requires that sufficient acetate be added to promote Geobacter species growth. We hypothesized that under acetate-limiting conditions, subsurface Geobacter species would increase the expression of either putative acetate symporters genes (aplI and aplII). Acetate was added to a uranium-contaminated aquifer (Rifle, CO) in two continuous amendments separated by 5 days of groundwater flush to create changing acetate concentrations. While the expression of aplI in monitoring well D04 (high acetate) weakly correlated with the acetate concentration over time, the transcript levels for this gene were relatively constant in well D08 (low acetate). At the lowest acetate concentrations during the groundwater flush, the transcript levels of aplII were the highest. The expression of aplII decreased 2-10-fold upon acetate reintroduction. However, the overall instability of acetate concentrations throughout the experiment could not support a robust conclusion regarding the role of apl genes in response to acetate limitation under field conditions, in contrast to previous chemostat studies, suggesting that the function of a microbial community cannot be inferred based on lab experiments alone.

  13. Quality by Design approach in the development of hydrophilic interaction liquid chromatographic method for the analysis of iohexol and its impurities.

    PubMed

    Jovanović, Marko; Rakić, Tijana; Tumpa, Anja; Jančić Stojanović, Biljana

    2015-06-10

    This study presents the development of hydrophilic interaction liquid chromatographic method for the analysis of iohexol, its endo-isomer and three impurities following Quality by Design (QbD) approach. The main objective of the method was to identify the conditions where adequate separation quality in minimal analysis duration could be achieved within a robust region that guarantees the stability of method performance. The relationship between critical process parameters (acetonitrile content in the mobile phase, pH of the water phase and ammonium acetate concentration in the water phase) and critical quality attributes is created applying design of experiments methodology. The defined mathematical models and Monte Carlo simulation are used to evaluate the risk of uncertainty in models prediction and incertitude in adjusting the process parameters and to identify the design space. The borders of the design space are experimentally verified and confirmed that the quality of the method is preserved in this region. Moreover, Plackett-Burman design is applied for experimental robustness testing and method is fully validated to verify the adequacy of selected optimal conditions: the analytical column ZIC HILIC (100 mm × 4.6 mm, 5 μm particle size); mobile phase consisted of acetonitrile-water phase (72 mM ammonium acetate, pH adjusted to 6.5 with glacial acetic acid) (86.7:13.3) v/v; column temperature 25 °C, mobile phase flow rate 1 mL min(-1), wavelength of detection 254 nm.

  14. Liquid chromatographic determination of melamine in beverages.

    PubMed

    Ishiwata, H; Inoue, T; Yamazaki, T; Yoshihira, K

    1987-01-01

    A liquid chromatographic method is described for the determination of melamine in beverages. Melamine is separated by column chromatography using cation and anion exchange resin and determined by ion-pair liquid chromatography using an ODS column and a mixture of acetonitrile and 0.05M phosphate buffer (pH 3.0) containing 0.005M sodium 1-laurylsulfate (1 + 4, v/v) as mobile phase. Recoveries of melamine ranged between 90.3 +/- 7.8 and 102.1 +/- 5.6% at levels of 0.6 to 2.4 ppm in 4 kinds of beverages. The quantitation limit was 2.5 micrograms melamine in 50 mL beverage. The method was applied to the migration test of melamine from melamine-formaldehyde resin products to the beverages.

  15. Preparation of vinyl acetate

    DOEpatents

    Tustin, Gerald Charles; Zoeller, Joseph Robert; Depew, Leslie Sharon

    1998-01-01

    This invention pertains to the preparation of vinyl acetate by contacting a mixture of hydrogen and ketene with a heterogeneous catalyst containing a transition metal to produce acetaldehyde, which is then reacted with ketene in the presence of an acid catalyst to produce vinyl acetate.

  16. Preparation of vinyl acetate

    DOEpatents

    Tustin, G.C.; Zoeller, J.R.; Depew, L.S.

    1998-03-24

    This invention pertains to the preparation of vinyl acetate by contacting a mixture of hydrogen and ketene with a heterogeneous catalyst containing a transition metal to produce acetaldehyde, which is then reacted with ketene in the presence of an acid catalyst to produce vinyl acetate.

  17. Determination of biocides as well as some biocide metabolites from facade run-off waters by solid phase extraction and high performance liquid chromatographic separation and tandem mass spectrometry detection.

    PubMed

    Bester, K; Lamani, X

    2010-08-06

    Biocides are used to protect buildings, boats, and other materials from microbial infestations. A huge variety of compounds are being used: isothiazolinones, e.g., to prevent bacterial growth in paints, triazines and phenylureas against algal growth on water exposed materials while carbamates are used against fungal investations. However these biocides can be leached from the respective materials. As these are very effective compounds it is important to know the concentrations of these biocides in the leachates as well as their leaching behaviour to assess their risk to the environment. In this study, a method for the determination of biocides from facade material run-off water by means of high performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) was developed. Due to the amphiphilic character and the expected varying pH-values in the samples, the extractions as well as the HPLC-method development proved to be demanding. The water samples (leachates) were buffered with a phosphate buffer to pH 7. As some of the biocides are very hydrophilic, different SPE cartridges were tested to identify the SPE material with the highest recovery rates for all compounds. For gaining a good separation, analyte trapping was performed on the HPLC column. Quantification was performed using a mass spectrometer in multi-reaction monitoring with two transitions per compound. The final recovery rates were conducted using a cartridge with a divenylbenzyl polymer sorbent. A combination of methanol and acetonitrile as eluents was used to reach recovery rates in the range of 70-100%. The limit of quantification for the compounds of interest ranged from 0.01 to 0.1 microg/L.

  18. Optimization and Validation of High-Performance Chromatographic Condition for Simultaneous Determination of Adapalene and Benzoyl Peroxide by Response Surface Methodology

    PubMed Central

    Huang, Yaw-Bin; Wu, Pao-Chu

    2015-01-01

    The aim of this study was to develop a simple and reliable high-performance chromatographic (HPLC) method for simultaneous analysis of adapalene and benzoyl peroxide in pharmaceutical formulation by response surface methodology (RSM). An optimized mobile phase composed of acetonitrile, tetrahydrofuran and water containing 0.1% acetic acid at a ratio of 25:50:25 by volume was successfully predicted by using RSM. An isocratic separation was achieved by using the condition. Furthermore, the analytical method was validated in terms of specificity, linearity, accuracy and precision in a range of 80% to 120% of the expected concentration. Finally, the method was successfully applied to the analysis of a commercial product. PMID:25793581

  19. Chromatographic tandam mass spectrometric detection of papaverine and its major metabolites in rat urine

    NASA Astrophysics Data System (ADS)

    Peng, Zhihong; Song, Wei; Han, Fengmei; Chen, Huaixia; Zhu, Mingming; Chen, Yong

    2007-10-01

    A rapid, sensitive and specific liquid chromatographic-electrospray ionization (ESI) tandem ion trap mass spectrometric method has been developed for identification of papaverine and its metabolites in rat urine. Six healthy rats were administrated a single dose (100 mg/kg) of papaverine by oral gavage. The urine were sampled for 0-24 h and purified by using a C18 solid-phase extraction cartridge, then the purified urine samples were separated on a reversed-phase C18 column using methanol/2 mmol/L ammonium acetate (70:30, v/v, adjusted to pH 3.5 with formic acid) as mobile phase and detected by an on-line MS detector. Identification and structural elucidation of the metabolites were performed by comparing their changes in molecular mass ([Delta]m) and full scan MSn spectra with those of the parent drug. The results indicated that there were 14 metabolites in rat urine, such as de-methoxyl, hydroxyl, glucuronide and sulfate conjugated metabolites and so on. All these metabolites were reported for the first time.

  20. High-performance thin-layer chromatographic determination of lamotrigine in serum.

    PubMed

    Patil, Kuldeep M; Bodhankar, Subhash L

    2005-09-05

    A simple and rapid high-performance thin-layer chromatographic (HPTLC) determination of lamotrigine (LTG) in serum is reported. The method involves extraction of the drug by ethyl acetate followed by separation on TLC silica plates using a mixture of toluene-acetone-ammonia (7:3:0.5), as eluting solvent. Densitometric analysis was carried out at 312 nm with lamotrigine being detected at Rf of 0.54. The analytical method has excellent linearity (r=0.998) in the range of 20-300 ng/spot. This assay range is adequate for analyzing human serum, as it corresponds to lamotrigine concentrations measured in human serum from epileptic patients. The method was validated for sensitivity, selectivity, extraction efficiency, accuracy and intra and inter-day reproducibility. The limit of detection and limit of quantification were found to be 6.4 and 10.2 ng, respectively. Good accuracy is reported in the range of 92.06-97.12% and high precision with %CV in range of 0.53-2.59. The method was applied for determination of serum lamotrigine levels in epileptic patients and in pharmacokinetic study of lamotrigine administered orally to rabbits.

  1. Ask the experts: chromatographic baselines.

    PubMed

    Smith, Graeme; James, Christopher A; Scott, Rebecca; Woolf, Eric

    2014-05-01

    Bioanalysis invited a selection of leading researchers to express their views on chromatographic baseline assignment in the bioanalytical laboratory. The topics discussed include the challenges presented with ensuring automated baseline assignment is correct, when reintegration is necessary, regulation and consistency in terminology. Their enlightening responses provide a valuable insight into developing an industry consensus towards reintegration. An accompanying commentary article in this issue, authored by Howard Hill and colleagues (Huntingdon Life Sciences), provides background to this much debated topic.

  2. Nanofabrication in cellulose acetate.

    PubMed

    Zeng, Hongjun; Lajos, Robert; Metlushko, Vitali; Elzy, Ed; An, Se Young; Sautner, Joshua

    2009-03-07

    We have demonstrated nanofabrication with commercialized cellulose acetate. Cellulose acetate is used for bulk nanofabrication and surface nanofabrication. In bulk nanofabrication, cellulose acetate reacts with an e-beam and permanent patterns are formed in it instead of being transferred to other substrates. We have studied the nano relief modulation performance of cellulose acetate before and after development. The depth of the nanopatterns is magnified after development, and is varied by exposing dosage and line width of the pattern. The thinnest 65 nm wide line is achieved in the bulk fabrication. We also demonstrate a binary phase Fresnel lens array which is directly patterned in a cellulose acetate sheet. Because of its unique mechanical and optical properties, cellulose is a good candidate for a template material for soft imprinting lithography. In the surface nanofabrication, cellulose acetate thin film spin-coated on silicon wafers is employed as a new resist for e-beam lithography. We achieved 50 nm lines with 100 nm pitches, dots 50 nm in diameter, and single lines with the smallest width of 20 nm. As a new resist of e-beam lithography, cellulose acetate has high resolution comparable with conventional resists, while having several advantages such as low cost, long stock time and less harmfulness to human health.

  3. Characterization of Gas Chromatographic Liquid Phases Using McReynolds Constants. An Experiment for Instrumental Analysis Laboratory.

    ERIC Educational Resources Information Center

    Erskine, Steven R.; And Others

    1986-01-01

    Describes a laboratory experiment that is designed to aid in the understanding of the fundamental process involved in gas chromatographic separations. Introduces the Kovats retention index system for use by chemistry students to establish criteria for the optimal selection of gas chromatographic stationary phases. (TW)

  4. New liquid chromatographic-chemometric approach for the determination of sunset yellow and tartrazine in commercial preparation.

    PubMed

    Dinç, Erdal; Aktaş, A Hakan; Ustündağ, Ozgür

    2005-01-01

    A new liquid chromatographic (LC)-chemometric approach was developed for the determination of sunset yellow (SUN) and tartrazine (TAR) in commercial preparations. This approach uses LC and chemometric calibration methods, i.e., classical least-squares (CLS), principal component regression (PCR), and partial-least squares (PLS), simultaneously. The combined LC-chemometric approaches, denoted as LC-CLS, LC-PCR, and LC-PLS, are based on photodiode array (PDA) detection at multiple wavelengths. Optimum chromatographic separation of SUN and TAR with allura red as the internal standard (IS) was obtained by using a Waters Symmetry C18 column, 5 microm, 4.6 x 250 mm, and 0.2 M acetate buffer (pH 5)-acetonitrile-methano-bidistilled water (55 + 20 + 15 + 10, v/v) as the mobile phase at a flow rate of 1.9 mL/min. The LC data sets consisting of the ratios of analyte peak areas to the IS peak area were obtained by using PDA detection at 5 wavelengths (465, 470, 475, 480, and 485 nm). LC-chemometric calibrations for SUN and TAR were separately constructed by using the relationship between the peak-area ratio and the training sets for each colorant. LC-chemometric approaches were tested for different synthetic mixtures containing SUN and TAR in the presence of the IS. These LC-chemometric calibrations were applied to a commercial preparation of the 2 colorants. The experimental results of the LC-chemometric approaches were compared with those obtained by a developed classical LC method using single-wavelength detection.

  5. Recovery of acetic acid from waste streams by extractive distillation.

    PubMed

    Demiral, H; Yildirim, M Ercengiz

    2003-01-01

    Wastes have been considered to be a serious worldwide environmental problem in recent years. Because of increasing pollution, these wastes should be treated. However, industrial wastes can contain a number of valuable organic components. Recovery of these components is important economically. Using conventional distillation techniques, the separation of acetic acid and water is both impractical and uneconomical, because it often requires large number of trays and a high reflux ratio. In practice special techniques are used depending on the concentration of acetic acid. Between 30 and 70% (w/w) acetic acid contents, extractive distillation was suggested. Extractive distillation is a multicomponent-rectification method similar in purpose to azeotropic distillation. In extractive distillation, to a binary mixture which is difficult or impossible to separate by ordinary means, a third component termed an entrainer is added which alters the relative volatility of the original constituents, thus permitting the separation. In our department acetic acid is used as a solvent during the obtaining of cobalt(III) acetate from cobalt(II) acetate by an electrochemical method. After the operation, the remaining waste contains acetic acid. In thiswork, acetic acid which has been found in this waste was recovered by extractive distillation. Adiponitrile and sulfolane were used as high boiling solvents and the effects of solvent feed rate/solution feed rate ratio and type were investigated. According to the experimental results, it was seem that the recovery of acetic acid from waste streams is possible by extractive distillation.

  6. Synthesis of Cellulose Acetate from Cotton Byproducts

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cotton burr and cottonseed hull are relatively inexpensive cotton byproducts. In an effort to derive greater value out of these natural renewable materials, we have succeeded in converting part of them into cellulose acetate without prior chemical breakdown or physical separation of cellulose, ligni...

  7. Development and validation of a reversed-phase ultra-performance liquid chromatographic method for assay of lacidipine and related substances.

    PubMed

    Mohan, Arivozhi; Patel, Hitesh B; Saravanan, Dhandayutham

    2011-01-01

    A simple isocratic, RP-ultra-performance LC method was developed and validated for the determination of lacidipine, three process impurities formed during synthesis, and three degradation products present in drug substance and the drug product. An efficient chromatographic separation was achieved on an Acquity BEH C18 column using pH 4.5 ammonium acetate-acetic acid buffer-methanol (70 + 30, v/v) mobile phase. The monitoring wavelength was 240 nm, and the flow rate 0.25 mL/min. Forced degradation studies using acid, alkali, peroxide, water, heat, and light were conducted, and all impurities were separated. The method was validated successfully for specificity, precision, linearity, accuracy, LOD, LOQ, and robustness, according to International Conference on Harmonization guidelines. The linearity of the calibration curve for lacidipine and each impurity was found to be very good (r2 > 0.999). This method is shown to be suitable for analysis of lacidipine to evaluate the quality of drug substance and a drug product.

  8. ELECTRICALLY ACTUATED, PRESSURE-DRIVEN LIQUID CHROMATOGRAPHY SEPARATIONS IN MICROFABRICATED DEVICES

    PubMed Central

    Fuentes, Hernan V.; Woolley, Adam T.

    2012-01-01

    Electrolysis-based micropumps integrated with microfluidic channels in micromachined glass substrates are presented. Photolithography combined with wet chemical etching and thermal bonding enabled the fabrication of multi-layer devices containing electrically actuated micropumps interfaced with sample and mobile phase reservoirs. A stationary phase was deposited on the microchannel walls by coating with 10% (w/w) chlorodimethyloctadecylsilane in toluene. Pressure-balanced injection was implemented by controlling the electrolysis time and voltage applied in the two independent micropumps. Current fluctuations in the micropumps due to the stochastic formation of bubbles on the electrode surfaces were determined to be the main cause of variation between separations. On-chip electrochemical pumping enabled the loading of pL samples with no dead volume between injection and separation. A mobile phase composed of 70% acetonitrile and 30% 50 mM acetate buffer (pH 5.45) was used for the chromatographic separation of three fluorescently labeled amino acids in <40 s with an efficiency of >3000 theoretical plates in a 2.5-cm-long channel. Our results demonstrate the potential of electrochemical micropumps integrated with microchannels to perform rapid chromatographic separations in a microfabricated platform. Importantly, these devices represent a significant step toward the development of miniaturized and fully integrated liquid chromatography systems. PMID:17960281

  9. Liquid chromatographic determination of progestogens in animal fat.

    PubMed

    Andresen, M T; Fesser, A C

    1996-01-01

    A liquid chromatographic method was developed for determination of 3 progestogens-melengestrol acetate, megestrol acetate, and chlormadinone acetate-found in edible tissue at concentrations between 10 and 1000 ppb. These progestogens are commonly used as feed additives to control herd estrus and to improve feed efficiency. Rendered fat was extracted with acetonitrile, washed with hexane, and dried. The remaining lipids were saponified with sodium hydroxide and precipitated with magnesium chloride. The progestogens were extracted from the basic solution with hexane, dried, and cleaned up on a cyanopropyl solid-phase extraction column in the normal-phase mode. The eluate was dried and reconstituted with acetonitrile-water (7 + 3, v/v). Chromatography was performed on a 5 microns high-carbon load C18 column with acetonitrile-water (7 + 3, v/v) at 1 mL/min and UV detection at 291 nm. Recoveries from fortified samples ranged from 84 to 116%. The limit of quantitation was 10 ppb for both beef and pork. The detection limit was 3 ppb.

  10. High productivity chromatographic separations on monolithic capillary columns

    NASA Astrophysics Data System (ADS)

    Korolev, A. A.; Shiryaeva, V. E.; Popova, T. P.; Kurganov, A. A.

    2013-03-01

    The productivity of monolithic capillary columns based on silica gel and polymers of different polarities (divinylbenzene and ethyleneglycol dimethacrylate) is investigated using a model mixture of light hydrocarbons. It is shown that the productivity of a column is noticeably affected by the type of gas carrier. The highest productivity is observed when using carbon dioxide or dinitrogen monoxide as the gas carrier. The lowest productivity is observed when uisng hydrogen or helium.

  11. cis- and trans-Stilbenes: Chromatographic Separation and Photochemical Isomerization.

    ERIC Educational Resources Information Center

    Levine, Samuel G.; And Others

    1988-01-01

    Describes an experiment that is to be performed midway in the first semester of an undergraduate organic chemistry laboratory coinciding with the students' introduction to cis-trans isomerism in the study of alkenes. Discusses the apparatus, materials, experimental procedure, historical significance, and results. (CW)

  12. The chromatographic separation of enantiomers through nanoscale design.

    PubMed

    Sancho, Raquel; Minguillón, Cristina

    2009-03-01

    The pharmacological implications of chirality in drugs and the strict legislation in this regard have led to the development of efficient enantioselective technologies to obtain enantiomerically pure compounds and to analyze their quality. However, although the most popular technique for enantioselective analysis is HPLC, the advent of nanotechnologies opens up great possibilities regarding the development of high throughput methods and processes. This tutorial review describes the state of the art in the application of nanoparticles or nanostructured materials to enantioseparation. The possibilities for this kind of materials, previously modified to include conventional chiral selectors, or the use as chiral selectors of those intrinsically chiral are considered.

  13. Using Aspen to Teach Chromatographic Bioprocessing: A Case Study in Weak Partitioning Chromatography for Biotechnology Applications

    ERIC Educational Resources Information Center

    Evans, Steven T.; Huang, Xinqun; Cramer, Steven M.

    2010-01-01

    The commercial simulator Aspen Chromatography was employed to study and optimize an important new industrial separation process, weak partitioning chromatography. This case study on antibody purification was implemented in a chromatographic separations course. Parametric simulations were performed to investigate the effect of operating parameters…

  14. Polyaniline Membranes for Separation Applications

    DTIC Science & Technology

    2007-11-02

    High quality membranes of poly aniline/ethylaniline copolymers along with polyaniline /polyimide blends have been synthesized . Water permeates... polyaniline is among the most selective membranes yet developed for water/acetic acid separations: e.g. at 50% water/50% acetic acid the selectivity alpha is

  15. Isolation and characterization of esters of indole-3-acetic acid from the liquid endosperm of the horse chestnut (Aesculus species)

    NASA Technical Reports Server (NTRS)

    Domagalski, W.; Schulze, A.; Bandurski, R. S.

    1987-01-01

    Esters of indole-3-acetic acid were extracted and purified from the liquid endosperm of immature fruits of various species of the horse chestnut (Aesculus parviflora, A. baumanni, A. pavia rubra, and A. pavia humulis). The liquid endosperm contained, at least 12 chromatographically distinct esters. One of these compounds was purified and characterized as an ester of indole-3-acetic acid and myo-inositol. A second compound was found to be an ester of indole-3-acetic acid and the disaccharide rutinose (glucosyl-rhamnose). A third compound was partially characterized as an ester of indole-3-acetic acid and a desoxyaminohexose.

  16. Dynamic Protonation Equilibrium of Solvated Acetic Acid

    SciTech Connect

    Gu, Wei; Frigato, Tomaso; Straatsma, TP; Helms, Volkhard H.

    2007-04-13

    For the first time, the dynamic protonation equilibrium between an amino acid side chain analogue and bulk water as well as the diffusion properties of the excess proton were successfully reproduced through unbiased computer simulations. During a 50 ns Q-HOP MD simulation, two different regimes of proton transfer were observed. Extended phases of frequent proton swapping between acetic acid and nearby water were separated by phases where the proton freely diffuses in the simulation box until it is captured again by acetic acid. The pKa of acetic acid was calculated around 3.0 based on the relative population of protonated and deprotonated states and the diffusion coefficient of excess proton was computed from the average mean squared displacement in the simulation. Both calculated values agree well with the experimental measurements.

  17. Comparison of three liquid chromatographic methods for egg-white protein analysis.

    PubMed

    Awadé, A C; Efstathiou, T

    1999-02-19

    This paper describes and compares three chromatographic methods for the analysis of egg-white proteins. Gel-permeation chromatography allowed the separation of seven peaks from egg white, with an almost total protein recovery. A clean separation of ovomucin and lysozyme from the bulk of the proteins was obtained with this method. Reversed-phase high-performance liquid chromatography led to the fractionation of at least eight peaks. With this chromatographic method, the recovery was relatively poor. Approximately 30% of the ovalbumin was retained in the column after the elution. Finally, eleven chromatographic peaks were separated from egg white by high-performance liquid chromatography on an anion-exchange column. The recovery of proteins was almost total. The latter method afforded higher resolution.

  18. Evaluation of sequential injection chromatography for reversed phase separation of triazine herbicides exploiting monolithic and core-shell columns.

    PubMed

    de Prá Urio, Ricardo; Masini, Jorge C

    2015-01-01

    This paper describes the development of reversed phase sequential injection chromatography (SIC) methods for separation of simazine (SIM) and atrazine (AT), as well as their metabolites deethylatrazine (DEA), deisopropylatrazine (DIA) and hydroxyatrazine (HAT) exploiting silica based monolithic (50 × 4.6 mm) and core-shell (30 × 4.6 mm, 2.7 µm particles) columns. The separation was made by stepwise elution with two mobile phases: MP1 composed of 15:85 (v/v) acetonitrile: 2.5 mmol L(-1) acetic acid/ammonium acetate buffer (pH 4.2), and MP2, composed of 35:65 (v/v) acetonitrile: 2.5 mmol L(-1) acetic acid/ammonium acetate buffer (pH 4.2).The less hydrophobic compounds (DIA, HAT and DEA) eluted with MP1, whereas SIM and AT eluted with MP2. The method using core-shell column exhibited better chromatographic efficiency compared with monolithic column for separation of SIM and AT, but failed to provide base line separation of DIA and HAT. The proposed composition of mobile phases enabled the monolithic column to separate all the studied compounds with resolution >2.3 at flow rate of 35 µL s(-1) and sampling throughput of 8 analyses per hour, whereas in the core-shell the maximum flow rate allowed in the SIC system was 8 µL s(-1) (sampling throughput of 3 analyses per hour). The limits of detection were between 24 µg L(-1) (AT) and 40 µg L(-1) (DEA) using the monolithic column, and between 20 µg L(-1) (SIM) and 38 µg L(-1) (DEA) with the core-shell. Ultrasound-assisted extraction (80:20 v/v acetonitrile:water) of a soil sample enriched with the five triazines (250, 500 and 1000 µg kg(-1)) resulted recoveries between 51% and 121% of the spiked concentrations.

  19. Rapid and sensitive LC-MS/MS method for determination of megestrol acetate in human plasma: application to a human pharmacokinetic study.

    PubMed

    Seo, Ji-Hyung; Park, Ji-Sun; Jo, Min-Ho; Park, Mi-Sun; Ryu, Ju-Hee; Cho, Young-Wuk; Shim, Wang-Sup; Noh, Gyu-Jeong; Lee, Kyung-Tae

    2013-04-01

    A rapid, simple and fully validated LC-MS/MS method was developed and validated for the determination of megestrol acetate in human plasma using tolbutamide as an internal standard (IS) after one-step liquid-liquid extraction with methyl-tert-butyl-ether. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the transitions m/z 385.5 → 267.1 for megestrol acetate and m/z 271.4 → 155.1 for IS. Chromatographic separation was performed on a YMC Hydrosphere C18 column with an isocratic mobile phase, which consisted of 10 mm ammonium formate buffer (adjusted to pH 5.0 with formic acid)-methanol (60:40, v/v) at a flow rate of 0.4 mL/min. The achieved lower limit of quantitation (LLOQ) was 1 ng/mL (signal-to-noise ratio > 10) and the standard calibration curve for megestrol acetate was linear (r > 0.99) over the studied concentration range (1-2000 ng/mL). The proposed method was fully validated by determining its specificity, linearity, LLOQ, intra- and inter-day precision and accuracy, recovery, matrix effect and stability. The validated LC-MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of megestrol acetate after oral administration of a single dose 800 mg of megestrol acetate (Megace™) to five healthy Korean male volunteers under fed conditions.

  20. Proteomic analysis on acetate metabolism in Citrobacter sp. BL-4.

    PubMed

    Kim, Young-Man; Lee, Sung-Eun; Park, Byeoung-Soo; Son, Mi-Kyung; Jung, Young-Mi; Yang, Seung-Ok; Choi, Hyung-Kyoon; Hur, Sung-Ho; Yum, Jong Hwa

    2012-01-01

    Mass production of glucosamine (GlcN) using microbial cells is a worthy approach to increase added values and keep safety problems in GlcN production process. Prior to set up a microbial cellular platform, this study was to assess acetate metabolism in Citrobacter sp. BL-4 (BL-4) which has produced a polyglucosamine PGB-2. The LC-MS analysis was conducted after protein separation on the 1D-PAGE to accomplish the purpose of this study. 280 proteins were totally identified and 188 proteins were separated as acetate-related proteins in BL-4. Acetate was converted to acetyl-CoA by acetyl-CoA synthetase up-regulated in the acetate medium. The glyoxylate bypass in the acetate medium was up-regulated with over-expression of isocitrate lyases and 2D-PAGE confirmed this differential expression. Using (1)H-NMR analysis, the product of isocitrate lyases, succinate, increased about 15 times in the acetate medium. During acetate metabolism proteins involved in the lipid metabolism and hexosamine biosynthesis were over-expressed in the acetate medium, while proteins involved in TCA cycle, pentose phosphate cycle and purine metabolism were down-regulated. Taken together, the results from the proteomic analysis can be applied to improve GlcN production and to develop metabolic engineering in BL-4.

  1. Battery Separator from Polyphenylquinoxaline Polymer Blends.

    DTIC Science & Technology

    1978-04-01

    This work was performed to determine if polyphenylquinoxaline blends with polymers such as polyvinylacetate, cellulose acetate , can be made into...polymeric membranes useful as battery separators. It was found that polyphenylquinoxaline and cellulose acetate blends offer the best membrane useful as battery separators. (Author)

  2. Study of the separation limits of continuous solid support free liquid-liquid chromatography: separation of capsaicin and dihydrocapsaicin by centrifugal partition chromatography.

    PubMed

    Goll, Johannes; Frey, Andreas; Minceva, Mirjana

    2013-04-05

    Sequential centrifugal partition chromatography (sCPC) is a cyclic solid support-free liquid-liquid chromatographic process, in which a continuously introduced feed mixture is separated into two sequentially collected product streams. The few experimental demonstrations of this concept already revealed its potential for the preparative separation of pharmaceuticals and fine chemicals. In this work not only the possibilities, but also the limits of the sCPC technology are explored. A feed mixture consisting of capsaicin and dihydrocapsaicin, whose molecular structure differs in only one double bond, was selected for this purpose. The sCPC unit operating parameters needed for a complete separation of the feed mixture were selected using the recently published approach, which uses the partition coefficient of the feed components and the hydrodynamic characteristics of the system as input data. A complete separation of capsaicin and dihydrocapsaicin with the solvent system heptane/ethyl acetate/methanol/water:1/1/1/1 (v/v/v/v) was achieved, although the separation factor was only 1.32. The sCPC unit separation performance was successfully simulated using the cell model.

  3. Separation and quantification of microalgal carbohydrates.

    PubMed

    Templeton, David W; Quinn, Matthew; Van Wychen, Stefanie; Hyman, Deborah; Laurens, Lieve M L

    2012-12-28

    Structural carbohydrates can constitute a large fraction of the dry weight of algal biomass and thus accurate identification and quantification is important for summative mass closure. Two limitations to the accurate characterization of microalgal carbohydrates are the lack of a robust analytical procedure to hydrolyze polymeric carbohydrates to their respective monomers and the subsequent identification and quantification of those monosaccharides. We address the second limitation, chromatographic separation of monosaccharides, here by identifying optimum conditions for the resolution of a synthetic mixture of 13 microalgae-specific monosaccharides, comprised of 8 neutral, 2 amino sugars, 2 uronic acids and 1 alditol (myo-inositol as an internal standard). The synthetic 13-carbohydrate mix showed incomplete resolution across 11 traditional high performance liquid chromatography (HPLC) methods, but showed improved resolution and accurate quantification using anion exchange chromatography (HPAEC) as well as alditol acetate derivatization followed by gas chromatography (for the neutral- and amino-sugars only). We demonstrate the application of monosaccharide quantification using optimized chromatography conditions after sulfuric acid analytical hydrolysis for three model algae strains and compare the quantification and complexity of monosaccharides in analytical hydrolysates relative to a typical terrestrial feedstock, sugarcane bagasse.

  4. Separation and purification of five alkaloids from Aconitum duclouxii by counter-current chromatography.

    PubMed

    Wang, Yarong; Cai, Shining; Chen, Yang; Deng, Liang; Zhou, Xumei; Liu, Jia; Xu, Xin; Xia, Qiang; Lin, Mao; Zhang, Jili; Huang, Weili; Wang, Wenjun; Xiang, Canhui; Cui, Guozhen; Du, Lianfeng; He, Huan; Qi, Baohui

    2015-07-01

    C19 -diterpenoid alkaloids are the main components of Aconitum duclouxii Levl. The process of separation and purification of these compounds in previous studies was tedious and time consuming, requiring multiple chromatographic steps, thus resulted in low recovery and high cost. In the present work, five C19 -diterpenoid alkaloids, namely, benzoylaconine (1), N-deethylaconitine (2), aconitine (3), deoxyaconitine (4), and ducloudine A (5), were efficiently prepared from A. duclouxii Levl (Aconitum L.) by ethyl acetate extraction followed with counter-current chromatography. In the process of separation, the critical conditions of counter-current chromatography were optimized. The two-phase solvent system composed of n-hexane/ethyl acetate/methanol/water/NH3 ·H2 O (25%) (1:1:1:1:0.1, v/v) was selected and 148.2 mg of 1, 24.1 mg of 2, 250.6 mg of 3, 73.9 mg of 4, and 31.4 mg of 5 were obtained from 1 g total Aconitum alkaloids extract, respectively, in a single run within 4 h. Their purities were found to be 98.4, 97.2, 98.2, 96.8, and 96.6%, respectively, by ultra-high performance liquid chromatography analysis. The presented separation and purification method was simple, fast, and efficient, and the obtained highly pure alkaloids are suitable for biochemical and toxicological investigation.

  5. Michrochip chromatography using an open-tubular microchannel and a ternary water-ACN-ethyl acetate mixture carrier solution.

    PubMed

    Matsuda, Takafumi; Yamashita, Kenichi; Maeda, Hideaki; Hashimoto, Masahiko; Tsukagoshi, Kazuhiko

    2013-03-01

    A capillary chromatography system has been developed using a ternary mixed-solvents solution, i.e. water-hydrophilic/hydrophobic organic solvent mixture as a carrier solution. Here, we tried to carry out the chromatographic system on a microchip incorporating the open-tubular microchannels. A model analyte solution of isoluminol isothiocyanate (ILITC) and ILITC-labeled biomolecule was injected to the double T-junction part on the microchip. The analyte solution was delivered in the separation microchannel (40 μm deep, 100 μm wide, and 22 cm long) with the ternary water-ACN-ethyl acetate mixture carrier solution (3:8:4 volume ratio, the organic solvent rich or 15:3:2 volume ratio, the water-rich). The analyte, free-ILITC and labeled BSA mixture, was separated through the microchannel, where the carrier solvents were radially distributed in the separation channel generating inner and outer phases. The outer phase acts as a pseudo-stationary phase under laminar flow conditions in the system. The ILITC and the labeled BSA were eluted and detected with chemiluminescence reaction.

  6. Gas chromatographic analysis of trace gas impurities in tungsten hexafluoride.

    PubMed

    Laurens, J B; de Coning, J P; Swinley, J M

    2001-03-09

    Highly reactive fluorinated gaseous matrices require special equipment and techniques for the gas chromatographic analysis of trace impurities in these gases. The impurities that were analysed at the low-microg/l levels included oxygen, nitrogen, carbon dioxide, carbon monoxide, sulfur hexafluoride and hydrogen. This paper describes the use of a system utilising backflush column switching to protect the columns and detectors in the analysis of trace gas impurities in tungsten hexafluoride. Two separate channels were used for the analysis of H2, O2, N2, CO, CO2 and SF6 impurities with pulsed discharge helium ionisation detection.

  7. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, Thomas G.; Ives, Jeffrey T.

    1993-01-01

    A method and apparatus for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means.

  8. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, T.G.; Ives, J.T.

    1993-12-28

    A method and apparatus are presented for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means. 16 figures.

  9. Two-dimensional thin-layer chromatographic method for the analysis of ochratoxin A in green coffee.

    PubMed

    Ventura, Meritxell; Anaya, Ivan; Broto-Puig, Francesc; Agut, Montserrat; Comellas, Lluís

    2005-09-01

    A low-cost thin-layer chromatographic method has been developed for the presumptive measurement of ochratoxin A (OTA) at 5 microg/kg in green coffee beans. The analytical method consisted of extracting OTA by shaking the beans with a mixture of methanol and aqueous sodium bicarbonate solution, which was then purified by liquid-liquid partition into toluene. OTA was separated by normal-phase two-dimensional thin-layer chromatography and detected by visual estimation of fluorescence intensity under a UV lamp at 365 nm. The chromatography solvents were toluene-methanol-formic acid (8:2:0.03) for the first development and petroleum ether-ethyl acetate-formic acid (8:10:1) for the second dimension development. This method was tested with uncontaminated green coffee bean samples spiked with an OTA standard at four different concentrations (5, 10, 20, and 30 microg/kg). The method is rapid, simple, and very easy to implement in coffee-producing countries. It is highly selective and does not involve the use of chlorinated solvents in the sample extraction step. This inexpensive method has been applied to different types of green coffee samples from various countries (Zimbabwe, Brazil, India, Uganda, Colombia, and Indonesia) and different manufacturers, and no OTA below the detection limit of 5 microg/kg was detected in any samples analyzed.

  10. Development and Validation of Stability-indicating High Performance Liquid Chromatographic Method for the Estimation of Everolimus in Tablets

    PubMed Central

    Sharmila, D.; Rao, A. Lakshmana; Kalyani, L.

    2015-01-01

    The present study depicts the development of a validated reversed-phase high performance liquid chromatographic method for the determination of the everolimus in presence of degradation products or pharmaceutical excipients. Stress study was performed on everolimus and it was found that it degrade sufficiently in oxidizing and acidic conditions but less degradation was found in alkaline, neutral, thermal and photolytic conditions. The separation was carried out on Hypersil BDS C18 column (100×4.6 mm, 5 μ) column having particle size 5 μ using acetate buffer:acetonitrile (50:50 v/v) with pH 6.5 adjusted with orthophosphoric acid as mobile phase at flow rate of 1 ml/min. The wavelength of the detection was 280 nm. A retention time (Rt) nearly 3.110 min was observed. The calibration curve for everolimus was linear (r2=0.999) from range of 25-150 μg/ml with limit of detection and limit of quantification of 0.036 μg/ml and 0.109 μg/ml, respectively. Analytical validation parameters such as selectivity, specificity, linearity, accuracy and precision were evaluated and relative standard deviation value for all the key parameters were less than 2.0%. The recovery of the drug after standard addition was found to be 100.55%. Thus, the developed RP-HPLC method was found to be suitable for the determination of everolimus in tablets containing various excipients. PMID:26798176

  11. [Simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis].

    PubMed

    Song, Baohua; Ding, Xiaojing; Li, Jia; Wang, Zhi

    2012-09-01

    Benzalkonium chloride (BAC) is a mixture of alkyl substituted benzyl dimethylammonium chloride homologs (C12-BAC, C14-BAC and C16-BAC). Chlorhexidine acetate is a widely used effective component in compound chemical disinfectants. A method for the simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis (CE) was established. The CE analysis was carried out using an uncoated capillary with 50 microm i. d. and 37 cm total length. The running buffer was 150 mmol/L NaH2PO4-62.5 mmol/L H3PO4 (pH 2.5) containing 40% (v/v) acetonitrile. The sample medium was 50 mmol/L acetic acid-acetonitrile (1:1, v/v). The detection wavelength was 214 nm. The factors such as the buffer concentration and pH, the content of acetonitrile, which influenced the separation and accurate assay of compound chemical disinfectants were investigated in detail. The intra-day and inter-day precisions of the method were below 3. 0% and 3.7%, respectively. The limits of detection (LOD, signal to noise ratio (S/N) = 3) for chlorhexidine acetate, C12-BAC, Cl4-BAC and C16-BAC were 0. 3, 0.5, 0.5 and 0.5 mg/L, respectively. The limits of quantification (LOQ, S/N = 10) were 1.0, 1.5, 1.5, and 1.5 mg/L, respectively. The corrected peak area and the mass concentration of the four components mentioned above showed good linear relationships within the ranges of 1.0 - 400 mg/L, 1. 5 - 200 mg/L, 1.5 - 200 mg/L and 1.5 - 200 mg/L, with linear correlation coefficients (r) of 0.9995, 0.9998, 0.999 7 and 0.9998, respectively. The established method was used for the determination of the four disinfectants in the compound chemical disinfectants. The results were in good agreement with those obtained by the high performance liquid chromatographic method.

  12. Evaluation of Comprehensive 2-D Gas Chromatography-Time-Of-Flight Mass Spectrometry for 209 Chlorinated Biphenyl Congeners in Two Chromatographic Runs

    EPA Science Inventory

    This research evaluates a recently developed comprehensive 2-D GC coupled with a time-of-flight (TOF) mass spectrometer for the potential separation of 209 PCB congeners, using a sequence of 1-D and 2-D chromatographic modes. In two consecutive chromatographic runs, using a 40 m,...

  13. Gas Chromatographic Determination of Enrivonmentally Significant Pesticides.

    ERIC Educational Resources Information Center

    Rudzinski, Walter E.; Beu, Steve

    1982-01-01

    A chromatographic procedure for analyzing organophosphorus pesticides (such as PCB's, nitrosamines, and phthalate esters) in orange juice is described, including a summary of the method, instrumentation, methodology, results/discussion, and calculations. (JN)

  14. A Versatile, Automatic Chromatographic Column Packing Device

    ERIC Educational Resources Information Center

    Barry, Eugene F.; And Others

    1977-01-01

    Describes an inexpensive apparatus for packing liquid and gas chromatographic columns of high efficiency. Consists of stainless steel support struts, an Automat Getriebmotor, and an associated three-pulley system capable of 10, 30, and 300 rpm. (MLH)

  15. A Quantitative Gas Chromatographic Ethanol Determination.

    ERIC Educational Resources Information Center

    Leary, James J.

    1983-01-01

    Describes a gas chromatographic experiment for the quantitative determination of volume percent ethanol in water ethanol solutions. Background information, procedures, and typical results are included. Accuracy and precision of results are both on the order of two percent. (JN)

  16. Acetate Kinase Isozymes Confer Robustness in Acetate Metabolism

    PubMed Central

    Chan, Siu Hung Joshua; Nørregaard, Lasse; Solem, Christian; Jensen, Peter Ruhdal

    2014-01-01

    Acetate kinase (ACK) (EC no: 2.7.2.1) interconverts acetyl-phosphate and acetate to either catabolize or synthesize acetyl-CoA dependent on the metabolic requirement. Among all ACK entries available in UniProt, we found that around 45% are multiple ACKs in some organisms including more than 300 species but surprisingly, little work has been done to clarify whether this has any significance. In an attempt to gain further insight we have studied the two ACKs (AckA1, AckA2) encoded by two neighboring genes conserved in Lactococcus lactis (L. lactis) by analyzing protein sequences, characterizing transcription structure, determining enzyme characteristics and effect on growth physiology. The results show that the two ACKs are most likely individually transcribed. AckA1 has a much higher turnover number and AckA2 has a much higher affinity for acetate in vitro. Consistently, growth experiments of mutant strains reveal that AckA1 has a higher capacity for acetate production which allows faster growth in an environment with high acetate concentration. Meanwhile, AckA2 is important for fast acetate-dependent growth at low concentration of acetate. The results demonstrate that the two ACKs have complementary physiological roles in L. lactis to maintain a robust acetate metabolism for fast growth at different extracellular acetate concentrations. The existence of ACK isozymes may reflect a common evolutionary strategy in bacteria in an environment with varying concentrations of acetate. PMID:24638105

  17. Comparison of physicochemical and gas chromatographic polarity measures for simple organic compounds.

    PubMed

    Héberger, Károly; Zenkevich, Igor G

    2010-04-23

    The comparison of different polarity measures (parameters, descriptors, variables, scales, etc.) indicates that evaluation of interrelations between these measures is important for better understanding and interpretation of chemical and/or analytical data, especially for chromatographic separation. The best linear correlation between gas chromatographic and non-chromatographic polarity descriptors is revealed for the first time: this pair of variables is the difference of gas chromatographic retention indices on standard polar and non-polar phases as well as the difference between non-dimensional indices of boiling points (known in chromatography since mid-1980s as dispersion indices) and indices of molar refractions. The correlation helps chromatographers to find preferable chemical variables (features) to understand better the separation phenomena and to find better correlations in QSRR models. Principal component analysis (PCA) of ten frequently applied polarity measures shows their similarity and, at the same time, it shows the absence of anomalies within the set of simple organic molecules. A novel ranking method for ten polarity parameters points out that the two most informative polarity measures are (i) the non-dimensional index for boiling point and (ii) the difference in chromatographic retention indices on standard polar and non-polar stationary phases. On the other hand, the hydrophobicity parameter, log P, sometimes considered as polarity parameter in HPLC seems to be the worst one in description of "polarity" in gas chromatography. Surprisingly, such polarity measures like dipole moment and permittivity used often in organic chemistry does not provide the best correlation with gas chromatographic polarity measures.

  18. Preparation of dye-ligand affinity chromatographic packings based on monodisperse poly(glycidylmethacrylate-co-ethylenedimethacrylate) beads and their chromatographic properties.

    PubMed

    Wu, Feiyan; Zhu, Yan; Jia, Zhishen

    2006-11-17

    Monodisperse porous particles, poly(glycidylmethacrylate-co-ethylenedimethacrylate), P(GMA-EDMA) beads with diameter of 7 microm were prepared by a single-step swelling and polymerization method. The polymer particles were advantaged through immobilization of Procion Bule MX-R, which was incubated by epichlorohydrin via the epoxide groups on the particles surface. The Procion Bule MX-R-immobilized P(GMA-EDMA) beads were mechanically stable and acted as the rigid matrix for column chromatography in HPLC mode. The chromatographic properties of the dye-ligand affinity chromatographic stationary phase for biopolymers separation are discussed. This affinity column has advantages of enabling biopolymer separation, high efficiency and low backpressure. Lysozyme and BSA were fast separated within 10min using this affinity column. The column was also used for the purification of lysozyme from chicken egg white.

  19. Simultaneous determination of furfural, acetic acid, and 5-hydroxymethylfurfural in corncob hydrolysates using liquid chromatography with ultraviolet detection.

    PubMed

    Dong, Bo-Yu; Chen, Ye-Fu; Zhao, Chang-Chun; Zhang, Shi-Jie; Guo, Xue-Wu; Xiao, Dong-Guang

    2013-01-01

    A single-laboratory validation study was conducted using HPLC for detecting and quantifying acetic acid, furfural, and 5-hydroxymethylfurfural (HMF) in corncob hydrolysates. A pretreatment procedure using dilute sulfuric acid was optimized for corncob hydrolysis. The final hydrolysates were analyzed by HPLC using a C18 RP column with aqueous 0.01% (v/v) H2SO4-CH3OH (95 + 5) as the mobile phase at a flow rate of 1 mL/min. The wavelengths for detecting the three compounds were changed to their optimal UV detection wavelengths at the time of elution. The wavelength detection adjustments were as follow: 205 nm (0 to 4 min); 284 nm (4 to 7 min); and 276 nm (7 to 10 min). Separation was achieved with a chromatographic run time of 10 min. The calibration curves for the three compounds had correlation coefficients (r2) > or = 99.8%. The analytical range, as defined by the calibration curves, was 0.5-10 mg/L for acetic acid, 0.4-22 mg/L for furfural, and 0.1-18 mg/L for HMF. The LODs for acetic acid, furfural, and HMF were estimated to be 0.05, 0.03, and 0.02 mg/L, respectively; the LOQs were 0.196, 0.135, and 0.074 mg/L, respectively. The RSD values for the intraday precision study ranged from 0.31 to 2.22%, and from 0.57 to 2.43% for the interday study. The mean recovery rates in all compounds were between 100.08 and 101.49%.

  20. A chromatographic survey of methods for extacting long-chain grass fructans

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Fructans were extracted under different conditions from four cool-season forages in order to develop extraction, cleanup, and chromatographic separation protocols permitting optimal analysis of long-chain fructans. Adequate sample cleanup was achieved by passage through a C18 solid-phase extractio...

  1. Kallolide A acetate pyrazoline.

    PubMed

    Rodríguez-Escudero, Idaliz; Marrero, Jeffrey; Rodríguez, Abimael D

    2012-01-01

    IN THE CRYSTAL STRUCTURE OF KALLOLIDE A ACETATE PYRAZOLINE [SYSTEMATIC NAME: 7-methyl-16-oxo-4,10-bis-(prop-1-en-2-yl)-17,18-dioxa-14,15-diaza-tetra-cyclo-[9.4.2.1(6,9).0(1,12)]octa-deca-6,8,14-trien-5-yl acetate], C(23)H(28)N(2)O(5), there is a 12-member-ed carbon macrocyclic structure. In addition, there is a tris-ubstituted furan ring, an approximately planar γ-lactone ring [maximum deviation of 0.057 (3) Å] and a pyraz-oline ring, the latter in an envelope conformation. The pyrazoline and the γ-lactone rings are fused in a cis configuration. In the crystal, mol-ecules are linked by weak C-H⋯O inter-actions, forming a two-dimensional network parallel to (001). An intra-molecular C-H⋯O hydrogen bond is also present.

  2. Kallolide A acetate pyrazoline

    PubMed Central

    Rodríguez-Escudero, Idaliz; Marrero, Jeffrey; Rodríguez, Abimael D.

    2012-01-01

    In the crystal structure of kallolide A acetate pyrazoline [systematic name: 7-methyl-16-oxo-4,10-bis­(prop-1-en-2-yl)-17,18-dioxa-14,15-diaza­tetra­cyclo­[9.4.2.16,9.01,12]octa­deca-6,8,14-trien-5-yl acetate], C23H28N2O5, there is a 12-member­ed carbon macrocyclic structure. In addition, there is a tris­ubstituted furan ring, an approximately planar γ-lactone ring [maximum deviation of 0.057 (3) Å] and a pyraz­oline ring, the latter in an envelope conformation. The pyrazoline and the γ-lactone rings are fused in a cis configuration. In the crystal, mol­ecules are linked by weak C—H⋯O inter­actions, forming a two-dimensional network parallel to (001). An intra­molecular C—H⋯O hydrogen bond is also present. PMID:22259545

  3. Chromatographic determination of the diffusion coefficients of light hydrocarbons in polymers

    NASA Astrophysics Data System (ADS)

    Yakubenko, E. E.; Korolev, A. A.; Chapala, P. P.; Bermeshev, M. V.; Kanat'eva, A. Yu.; Kurganov, A. A.

    2017-01-01

    Gas-chromatographic determination of the diffusion coefficients that allows for the compressibility of the mobile phase has been suggested. The diffusion coefficients were determined for light hydrocarbons C1-C4 in four polymers with a high free volume, which are candidates for use as gas-separating membranes. The diffusion coefficients calculated from chromatographic data were shown to be one or two orders of magnitude smaller than the values obtained by the membrane method. This may be due to the presence of an additional flow through the membrane caused by the pressure gradient across the membrane in membrane methods.

  4. Chromatographic analysis of wheatgrass extracts

    PubMed Central

    Khan, Masood Shah; Parveen, Rabea; Mishra, Kshipra; Tulsawani, Rajkumar; Ahmad, Sayeed

    2015-01-01

    Aim: Wheatgrass (WG) is the shoot of Triticum aestivum Linn. belongs to the family Gramineae, and possess high chlorophyll content and essential vitamins, minerals, vital enzymes, amino acids, dietary fibers etc., It has been shown to possess anti-cancer, anti-ulcer, antioxidant, and anti-arthritic activity due to the presence of biologically active compounds, and minerals. Therefore, in the present study, high-performance thin layer chromatography (HPTLC), and high-performance liquid chromatography (HPLC) methods for qualitative and quantitative analysis have been proposed, which will help in quality evaluation of wheat grass extract. Materials and Methods: Samples for analysis were prepared in methanol and water simply by sonication. These were applied on pre-coated silica plate and chromatograms were developed using toluene: Ethyl acetate: Formic acid. HPLC analysis was done on Waters HPLC system using water, methanol, and acetonitrile as mobile phase. Merck C18 column has been used. Results: HPTLC finger printing of alcoholic extracts of WG was carried out and found 10–11 spots at different wavelengths 254, 366, and 435 nm. HPLC fingerprinting produced 22 peaks at 256 nm. Quantitative HPTLC analysis was done to determine the gallic acid content, and was found to be 0.077% w/w in aqueous extract. By HPLC, the content of gallic acid and rutin was found to be 0.07%, and 0.04% w/w in aqueous extract of WG. Conclusion: The developed HPLC and HPTLC fingerprinting method can be used for the quality control, and standardization of WG and its extracts used as nutritional supplement. PMID:26681880

  5. HILIC separation mechanisms of tetracyclines on amino bonded silica column

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Effects of mobile phase variations on the chromatographic separation on amino bonded silica column in hydrophilic interaction chromatography (HILIC) were investigated for four zwitterionic tetracyclines (TCs): oxytetracycline, doxycycline, chlortetracycline and tetracycline. A mixed-mode retention m...

  6. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.

    1996-01-01

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  7. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.

    1996-06-11

    A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.

  8. Portable gas chromatograph-mass spectrometer

    SciTech Connect

    Andresen, B.D.; Eckels, J.D.; Kimmins, J.F.; Myers, D.W.

    1994-12-31

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  9. Chromatographic properties PLOT multicapillary columns.

    PubMed

    Nikolaeva, O A; Patrushev, Y V; Sidelnikov, V N

    2017-03-10

    Multicapillary columns (MCCs) for gas chromatography make it possible to perform high-speed analysis of the mixtures of gaseous and volatile substances at a relatively large amount of the loaded sample. The study was performed using PLOT MCCs for gas-solid chromatography (GSC) with different stationary phases (SP) based on alumina, silica and poly-(1-trimethylsilyl-1-propyne) (PTMSP) polymer as well as porous polymers divinylbenzene-styrene (DVB-St), divinylbenzene-vinylimidazole (DVB-VIm) and divinylbenzene-ethylene glycol dimethacrylate (DVB-EGD). These MCCs have the efficiency of 4000-10000 theoretical plates per meter (TP/m) and at a column length of 25-30cm can separate within 10-20s multicomponent mixtures of substances belonging to different classes of chemical compounds. The sample amount not overloading the column is 0.03-1μg and depends on the features of a porous layer. Examples of separations on some of the studied columns are considered.

  10. Fast chiral chromatographic method development and validation for the quantitation of eszopiclone in human plasma using LC/MS/MS.

    PubMed

    Meng, Min; Rohde, Lisa; Cápka, Vladimír; Carter, Spencer J; Bennett, Patrick K

    2010-12-01

    Traditional chiral chromatographic separation method development is time consuming even for an experienced chromatographer. This paper describes the application of computer software ACD Lab to facilitate the development of chiral separation for the quantitation of eszopiclone using LC-MS/MS technology. Assisted by ACD/Chrom Manager and LC Simulator software, the optimal chiral chromatographic development was completed within hours. The baseline chiral separation was achieved with a total cycle time of 3 min. For sample extraction method development, a Waters Oasis Sorbent Selection Plate containing four different sorbents was utilized. Optimal conditions were determined using a single plate under various load, wash and elution conditions. This was followed by a GLP validation which demonstrated excellent intra- and inter-day accuracy and precision for the quantitation of eszopiclone in human plasma at 1.00-100 ng/mL range using LC/MS/MS technology. This method was utilized to support multiple clinic bioequivalence studies.

  11. METHOD OF SEPARATING PLUTONIUM

    DOEpatents

    Heal, H.G.

    1960-02-16

    BS>A method of separating plutonium from aqueous nitrate solutions of plutonium, uranium. and high beta activity fission products is given. The pH of the aqueous solution is adjusted between 3.0 to 6.0 with ammonium acetate, ferric nitrate is added, and the solution is heated to 80 to 100 deg C to selectively form a basic ferric plutonium-carrying precipitate.

  12. SEPARATION OF PLUTONYL IONS

    DOEpatents

    Connick, R.E.; McVey, Wm.H.

    1958-07-15

    A process is described for separating plutonyl ions from the acetate ions with which they are associated in certaln carrier precipitation methods of concentrating plutonium. The method consists in adding alkaline earth metal ions and subsequently alkalizing the solution, causing formation of an alkaltne earth plutonate precipitate. Barium hydroxide is used in a preferred embodiment since it provides alkaline earth metal ion and alkalizes the solution in one step forming insoluble barium platonate.

  13. Identification of dihydrogalangal acetate in galangal [Alpinia galangal (L.) Swartz] extracts.

    PubMed

    Yang, Xiaogen; Rohr, Martin; Jordan, Jason

    2009-04-22

    Dihydrogalangal acetate has been discovered for the first time in galangal roots [Alpinia galangal (L.) Swartz]. The compound has a taste sensation similar to galangal acetatethe pungent principle of galangalbut it is more stable in food and beverage applications. Therefore, dihydrogalangal acetate provides many advantages as a flavor ingredient for alcohol enhancement and taste modification. Dihydrogalangal acetate is present in approximately 0.0005% of fresh roots and in about 0.004% of dried roots. (S)-Dihydrogalangal acetate is found as the main optical isomer in galangal roots (98%), while its minor (R)-isomer is less abundant (2%). Enantiomers of galangal acetate and dihydrogalangal acetate were separated and evaluated by sensory analysis. (R)-Galangal acetate has a very faint woody and sweet aroma, and (R)-dihydrogalangal acetate is almost odorless, while (S)-galangal acetate has strong and (S)-dihydrogalangal acetate has weak pungent and woody notes. Although the aroma characters of these optical isomers are different, taste sensations were found to have no significant differences among galangal acetate, dihydrogalangal acetate, and their optical isomers.

  14. ADSORPTION METHOD FOR SEPARATING METAL CATIONS

    DOEpatents

    Khym, J.X.

    1959-03-10

    The chromatographic separation of fission product cations is discussed. By use of this method a mixture of metal cations containing Zr, Cb, Ce, Y, Ba, and Sr may be separated from one another. Mentioned as preferred exchange adsorbents are resins containing free sulfonic acid groups. Various eluants, such as tartaric acid, HCl, and citric acid, used at various acidities, are employed to effect the selective elution and separation of the various fission product cations.

  15. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  16. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  17. Nano-fabricated size exclusion chromatograph

    NASA Technical Reports Server (NTRS)

    Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; dle Castillo, L.; White, V.

    2002-01-01

    This poster describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through a microcolumn containing nano-fabricated features will have characteristics elution times that directly correlate to molecular weight.

  18. Functional chromatographic technique for natural product isolation†

    PubMed Central

    Lau, Eric C.; Mason, Damian J.; Eichhorst, Nicole; Engelder, Pearce; Mesa, Celestina; Kithsiri Wijeratne, E. M.; Gunaherath, G. M. Kamal B.; Leslie Gunatilaka, A. A.

    2015-01-01

    Natural product discovery arises through a unique interplay between chromatographic purification and biological assays. Currently, most techniques used for natural product purification deliver leads without a defined biological action. We now describe a technique, referred to herein as functional chromatography, that deploys biological affinity as the matrix for compound isolation. PMID:25588099

  19. Liquid chromatographic determination of beta-naphthoxyacetic acid in tomatoes.

    PubMed

    Gökmen, V; Acar, J

    1998-03-06

    An alternative high-performance liquid chromatographic method for the determination of beta-naphthoxyacetic acid (BNOA) in tomatoes is described. BNOA was extracted from tomatoes with acetone-dichloromethane (2:1). The extract was cleaned up by Bio-Beads S-X3 gel-permeation chromatography and by partitioning. A reversed-phase C18 column was used for HPLC analysis. The mobile phase was acetonitrile-2% acetic acid in water (50:50, v/v) pumped at a flow-rate of 1.0 ml/min. Retention time of BNOA was ca. 7 min with a percentage coefficient of variation of 0.71. Resolution of BNOA was good on the column. Percentage recoveries of BNOA were 79.5 +/- 6.82, 94.8 +/- 2.70 and 86.4 +/- 16.43 for the corresponding spiking levels of 0.5, 1.0 and 2.0 micrograms per g tomato, respectively. Analysis of 10 greenhouse tomato samples from local markets in Ankara showed no BNOA residue.

  20. Gas separation membranes

    DOEpatents

    Schell, William J.

    1979-01-01

    A dry, fabric supported, polymeric gas separation membrane, such as cellulose acetate, is prepared by casting a solution of the polymer onto a shrinkable fabric preferably formed of synthetic polymers such as polyester or polyamide filaments before washing, stretching or calendering (so called griege goods). The supported membrane is then subjected to gelling, annealing, and drying by solvent exchange. During the processing steps, both the fabric support and the membrane shrink a preselected, controlled amount which prevents curling, wrinkling or cracking of the membrane in flat form or when spirally wound into a gas separation element.

  1. Method to fabricate silicon chromatographic column comprising fluid ports

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.; Heller, Edwin J.; Adkins, Douglas R.

    2004-03-02

    A new method for fabricating a silicon chromatographic column comprising through-substrate fluid ports has been developed. This new method enables the fabrication of multi-layer interconnected stacks of silicon chromatographic columns.

  2. Liquid chromatographic determination of multiple sulfonamides, nitrofurans, and chloramphenicol residues in pasteurized milk.

    PubMed

    Perez, Norma; Gutierrez, Rey; Noa, Mario; Diaz, Gilberto; Luna, Hector; Escobar, Irma; Munive, Zenaida

    2002-01-01

    A rapid and selective liquid chromatographic method was developed to detect 6 sulfonamides, 3 nitrofurans, and chloramphenicol residues in pasteurized milk. The 10 drugs were extracted with chloroform-acetone and the organic phase was evaporated; the residues were dissolved in an aqueous sodium acetate buffer solution 0.02M (pH = 4.8), and the fat was removed by washing with hexane. The aqueous layer was collected, filtered, and injected. The 6 sulfonamides and chloramphenicol were detected at 275 nm ultraviolet (UV) using a gradient system starting with sodium acetate buffer solution-acetonitrile (95 + 5) and finishing with sodium acetate buffer solution-acetonitrile (80 + 20). Nitrofurans were detected at 375 nm (UV) isocratically with sodium acetate buffer solution-acetonitrile (80 + 20). For 50 ppb fortified milk, the average recoveries were (sulfathiazole) 65.52%; (sulfamerazine) 75.36%; (sulfamethazine) 93.94%; (sulfachlorpyridazine) 75.94%; (sulfamethoxazole) 85.18%; (sulfamonomethoxine) 83.45%; (chloramphenicol) 104.17%; (nitrofurazone) 91.81%; (furazolidone) 100.76%; and (furaltadone) 72.38%. Method detection limits ranged from 4 ppb (nitrofurazone) to 16 ppb (sulfamethazine). Some matrix interferences (3-7 ppb) were observed only with sulfonamides.

  3. Redox-Neutral α-Sulfenylation of Secondary Amines: Ring-Fused N,S-Acetals

    PubMed Central

    2015-01-01

    Secondary amines react with thiosalicylaldehydes in the presence of catalytic amounts of acetic acid to generate ring-fused N,S-acetals in redox-neutral fashion. A broad range of amines undergo α-sulfenylation, including challenging substrates such morpholine, thiomorpholine, and piperazines. Computational studies employing density functional theory indicate that acetic acid reduces the energy barriers of two separate steps, both of which involve proton transfer. PMID:24927364

  4. Battery Separators Based on Polyphenylquinoxaline Polymer Blends.

    DTIC Science & Technology

    1981-04-01

    concluded that PPQ/ Cellulose Acetate is a good candidate material for alkaline battery separators; however, because of cost considerations, it is not competative with similar state-of-the-art materials. (Author)

  5. Tadpole toxicity prediction using chromatographic systems.

    PubMed

    Fernández-Pumarega, Alejandro; Amézqueta, Susana; Fuguet, Elisabet; Rosés, Martí

    2015-10-30

    Toxicity has been emulated in tadpole species through chromatographic systems. The parameter studied to evaluate the non-specific toxicity of a compound is the narcosis concentration (Cnar), which is defined as the concentration needed for the immobilization of the organism. Because experimental investigation with animals is lengthy, costly, technically difficult, and ethically questionable, there is a great interest in developing surrogate physicochemical systems able to emulate biological systems to obtain the same information in a faster, more economic, and easier manner. In order to see which chromatographic systems would be able to emulate tadpole narcosis, both, tadpole narcosis data and data in several chromatographic and electrophoretic systems, were fitted to a linear solvation energy relationship (LSER) model. Thus, by comparison of the models it was possible to see which of the chromatographic systems were more similar to the biological one. The physicochemical systems that best emulate tadpole narcosis were an HPLC system based on an immobilized artificial membrane (IAM) column, and two micellar electrokinetic chromatography (MEKC) systems based on sodium taurocholate (STC) and a mixture of sodium dodecylsulphate (SDS) and Brij 35 as surfactants. A system based on a RP18 HPLC column also was selected for comparison because it is a common column in most analytical laboratories. To establish the models, a set of compounds with known Cnar values were analyzed in the chromatographic, and electrophoretic selected systems and, then, the retention factor (k) was correlated to the concentration of narcosis. Statistics showed that the system based on STC micelles was the best to emulate toxicity in tadpoles. The robustness and predictive ability of the developed models were validated.

  6. Hydrophobic polymer monoliths as novel phase separators: application in continuous liquid-liquid extraction systems.

    PubMed

    Peroni, Daniela; Vanhoutte, Dominique; Vilaplana, Francisco; Schoenmakers, Peter; de Koning, Sjaak; Janssen, Hans-Gerd

    2012-03-30

    Hydrophobic macroporous polymer monoliths are shown to be interesting materials for the construction of "selective solvent gates". With the appropriate surface chemistry and porous properties the monoliths can be made permeable only for apolar organic solvents and not for water. Different poly(butyl methacrylate-co-ethylene dimethacrylate) (BMA-EDMA) and poly(styrene-co-divinylbenzene) (PS-DVB) monoliths prepared with tailored chemistries and porosities were evaluated for this purpose. After extensive characterization, the PS-DVB monoliths were selected due to their higher hydrophobicity and their more suitable flow characteristics. BMA-EDMA monoliths are preferred for mid-polarity solvents such as ethyl acetate, for which they provide efficient separation from water. Breakthrough experiments confirmed that the pressures necessary to generate flow of organic solvents through PS-DVB monoliths were substantially lower than for water. A phase separator was constructed using the monoliths as the flow selector. This device was successfully coupled on-line with a chip-based continuous liquid-liquid-extraction (LLE) system with segmented flow. Efficient separation of different solvents was obtained across a wide range of flow rates (0.5-4.0 mL min(-1)) and aqueous-to-organic flow ratios (β=1-10). Good robustness and long life-time were also confirmed. The suitability of the device to perform simple, cheap, and reliable phase separation in a continuous LLE system prior to gas-chromatographic analysis was proven for some selected real-life applications.

  7. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... No. 62-54-4), also known as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may be produced by the calcium hydroxide neutralization of acetic acid. (b) The ingredient meets...

  8. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... No. 62-54-4), also known as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may be produced by the calcium hydroxide neutralization of acetic acid. (b) The ingredient meets...

  9. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... No. 62-54-4), also known as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may be produced by the calcium hydroxide neutralization of acetic acid. (b) The ingredient meets...

  10. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may be produced by the calcium hydroxide neutralization of acetic acid. (b) The ingredient meets the specifications of the...

  11. Pallidol hexa­acetate ethyl acetate monosolvate

    PubMed Central

    Mao, Qinyong; Taylor, Dennis K.; Ng, Seik Weng; Tiekink, Edward R. T.

    2013-01-01

    The entire mol­ecule of pallidol hexa­acetate {systematic name: (±)-(4bR,5R,9bR,10R)-5,10-bis­[4-(acet­yloxy)phen­yl]-4b,5,9b,10-tetra­hydro­indeno­[2,1-a]indene-1,3,6,8-tetrayl tetra­acetate} is completed by the application of twofold rotational symmetry in the title ethyl acetate solvate, C40H34O12·C4H8O2. The ethyl acetate mol­ecule was highly disordered and was treated with the SQUEEZE routine [Spek (2009 ▶). Acta Cryst. D65, 148–155]; the crystallographic data take into account the presence of the solvent. In pallidol hexa­acetate, the dihedral angle between the fused five-membered rings (r.m.s. deviation = 0.100 Å) is 54.73 (6)°, indicating a significant fold in the mol­ecule. Significant twists between residues are also evident as seen in the dihedral angle of 80.70 (5)° between the five-membered ring and the pendent benzene ring to which it is attached. Similarly, the acetate residues are twisted with respect to the benzene ring to which they are attached [C—O(carb­oxy)—C—C torsion angles = −70.24 (14), −114.43 (10) and −72.54 (13)°]. In the crystal, a three-dimensional architecture is sustained by C—H⋯O inter­actions which encompass channels in which the disordered ethyl acetate mol­ecules reside. PMID:24046702

  12. RAPID MEASUREMENTS OF NEPTUNIUM OXIDATION STATES USING CHROMATOGRAPHIC RESINS

    SciTech Connect

    Diprete, D; C Diprete, C; Mira Malek, M; Eddie Kyser, E

    2009-03-24

    The Savannah River Site's (SRS) H-Canyon facility uses ceric ammonium nitrate (CAN) to separate impure neptunium (Np) from a high sulfate feed stream. The material is processed using a two-pass solvent extraction purification which relies on CAN to oxidize neptunium to Np(VI) during the first pass prior to extraction. Spectrophotometric oxidation-state analyses normally used to validate successful oxidation to Np(VI) prior to extraction were compromised by this feed stream matrix. Therefore, a rapid chromatographic method to validate successful Np oxidation was developed using Eichrom Industries TRU and TEVA{reg_sign} resins. The method was validated and subsequently transferred to existing operations in the process analytical laboratories.

  13. Allyl-silica Hybrid Monoliths For Chromatographic Application

    NASA Astrophysics Data System (ADS)

    Guo, Wenjuan

    Column technology continues to be the most investigated topics in the separation world, since the column is the place where the chromatographic separation happens, making it the heart of the separation system. Allyl-silica hybrid monolithic material has been exploited as support material and potential stationary phases for liquid chromatography; the stationary phase anchored to the silica surface by Si-C bond, which is more pH stable than traditional stationary phase. First, nuclear magnetic resonance spectroscopy has been used to study the sol in the synthesis of allyl-silica hybrid monoliths. Allyl-trimethoxysilane (allyl-TrMOS), dimethyldimethoxysilane (DMDMOS) and tetramethoxysilane (TMOS) have been served as co-precursors in the sol-gel synthesis of organo-silica hybrid monolithic columns for liquid chromatography (LC). 29Si nuclear magnetic resonance (NMR) and 1H NMR spectroscopy were employed to monitor reaction profiles for the acid-catalyzed hydrolysis and initial condensation reactions of the individual precursor and the hybrid system. 29Si-NMR has also been used to identify different silane species formed during the reactions. The overall hydrolysis rate has been found to follow the trend DMDMOS > allyl-TrMOS > TMOS, if each precursor is reacted individually (homo-polymerization). Precursors show different hydrolysis rate when reacted together in the hybrid system than they are reacted individually. Cross-condensation products of TMOS and DMDMOS (QD) arise about 10 minutes of initiation of the reaction. The allyl-silica monolithic columns for capillary liquid chromatography can only be prepared in capillaries with 50 im internal diameter with acceptable performance. One of the most prominent problems related to the synthesis of silica monolithic structures is the volume shrinkage. The synthesis of allylfunctionalized silica hybrid monolithic structures has been studied in an attempt to reduce the volume shrinkage during aging, drying and heat treatment

  14. Studies on chromatographic fingerprint and fingerprinting profile-efficacy relationship of polygoni perfoliati herba.

    PubMed

    Tian, Li; Zhao, Yang; Zhou, Xin; Chen, Hua-Guo; Zhao, Chao; Gong, Xiao-Jian

    2013-01-01

    Polygoni Perfoliati Herba is widely used in China with antibacterium, anti-inflammatory, expectorant, antitumor, and antivirus activities. To reveal the mechanisms of the activities of Polygoni Perfoliati Herba, the relationship between the fingerprinting profile and its bioactivities was investigated. In the present study, high-performance liquid chromatographic (HPLC) fingerprinting method was developed. The established method was applied to analyze 51 batches of Polygoni Perfoliati Herba samples collected from different locations or in different harvesting times in China. Chemometrics, including similarity analysis, hierarchical clustering analysis, and principal component analysis, were used to express their similarities. It was found that similarity values of the samples were in the range of 0.432-0.998. The results of analgesic tests indicated that Polygoni Perfoliati Herba could significantly inhibit pain induced by hot plate and acetic acid in mice. The results of anti-inflammatory tests showed that Polygoni Perfoliati Herba had good anti-inflammatory effects (P < 0.01) in two models including dimethyl benzene-induced ear edema and acetic acid-induced peritoneal permeability in mice. Combining the results from chromatographic fingerprints with those from bioactivities, we found that seven peaks from Polygoni Perfoliati Herba were mainly responsible for analgesic and anti-inflammatory activities.

  15. Gas chromatographic determination of volatile congeners in spirit drinks: interlaboratory study.

    PubMed

    Kelly, J; Chapman, S; Brereton, P; Bertrand, A; Guillou, C; Wittkowski, R

    1999-01-01

    An interlaboratory study of a gas chromatographic (GC) method for the determination of volatile congeners in spirit drinks was conducted; 31 laboratories from 8 countries took part in the study. The method uses GC with flame ionization detection and incorporates several quality control measures which permit the choice of chromatographic system and conditions to be selected by the user. Spirit drink samples were prepared and sent to participants as 10 blind duplicate or split-level test materials for the determination of 1,1-diethoxyethane (acetal), 2-methylbutan-1-ol (active amyl alcohol), 3-methylbutan-1-ol (isoamyl alcohol), methanol (methyl alcohol), ethyl ethanoate (ethyl acetate), butan-1-ol (n-butanol), butan-2-ol (sec-butanol), 2-methylpropan-1-ol (isobutyl alcohol), propan-1-ol (n-propanol), and ethanal (acetaldehyde). The precision of the method for 9 of the 10 analytes was well within the range predicted by the Horwitz equation. The precision of the most volatile analyte, ethanal, was just above statistically predicted levels. This method is recommended for official regulatory purposes.

  16. How Much Can We Learn from a Single Chromatographic Experiment? A Bayesian Perspective.

    PubMed

    Wiczling, Paweł; Kaliszan, Roman

    2016-01-05

    In this work, we proposed and investigated a Bayesian inference procedure to find the desired chromatographic conditions based on known analyte properties (lipophilicity, pKa, and polar surface area) using one preliminary experiment. A previously developed nonlinear mixed effect model was used to specify the prior information about a new analyte with known physicochemical properties. Further, the prior (no preliminary data) and posterior predictive distribution (prior + one experiment) were determined sequentially to search towards the desired separation. The following isocratic high-performance reversed-phase liquid chromatographic conditions were sought: (1) retention time of a single analyte within the range of 4-6 min and (2) baseline separation of two analytes with retention times within the range of 4-10 min. The empirical posterior Bayesian distribution of parameters was estimated using the "slice sampling" Markov Chain Monte Carlo (MCMC) algorithm implemented in Matlab. The simulations with artificial analytes and experimental data of ketoprofen and papaverine were used to test the proposed methodology. The simulation experiment showed that for a single and two randomly selected analytes, there is 97% and 74% probability of obtaining a successful chromatogram using none or one preliminary experiment. The desired separation for ketoprofen and papaverine was established based on a single experiment. It was confirmed that the search for a desired separation rarely requires a large number of chromatographic analyses at least for a simple optimization problem. The proposed Bayesian-based optimization scheme is a powerful method of finding a desired chromatographic separation based on a small number of preliminary experiments.

  17. Separation of sugars by continuous annular chromatography

    SciTech Connect

    Howard, A.J.; Carta, G.; Byers, C.H.

    1987-08-01

    Continuous chromatographic separations of aqueous fructose-glucose-sucrose solutions have been investigated in a laboratory-scale continuous annular chromatograph (CAC) using calcium-exchanged Dowex 50W-X8 resin. Comparative studies have also been conducted using a conventional fixed-bed column packed with the same resin. Complete resolution of fructose-glucose mixtures could be obtained both in a 60-cm-long CAC and in a conventional column of the same length with a sugar feed concentration of up to 200 g/L. Partial resolution of sucrose in three component mixtures was also obtained, and the three sugars were completely separated from added higher-molecular-weight saccharides. Results have been analyzed in terms of approximate linear chromatographic theories and orthogonal collocation of exact mass transfer model equations for fixed and rotating beds. A systematic, comparative evaluation of factors affecting process performance and design procedures is presented.

  18. Continuous separation of proteins by annular chromatography

    SciTech Connect

    Bloomingburg, G.F.; Bauer, J.S.; Carta, G. ); Byers, C.H. )

    1991-05-01

    In this paper, the separation of protein mixtures by continuous annular chromatography (CAC) is studied in a preparative-scale apparatus. S-Sepharose, a strong-acid porous cation-exchange resin is used as the separation medium, and mixtures of albumin, hemoglobin and cytochrome c are used as model separation system. Equilibrium and mass-transfer parameters are developed for this system on the basis of fixed-bed chromatograph experiments. A mathematical model is then successfully used in conjunction with these parameters to simulate the performance of the CAC separations. The continuous separation performance of the annular apparatus is found to be essentially the same as the batchwise performance of an equivalent conventional chromatograph, making the unit attractive for preparative and process-scale applications where continuous throughput is desirable.

  19. PROCESS FOR THE SEPARATION OF HEAVY METALS

    DOEpatents

    Gofman, J.W.; Connick, R.E.; Wahl, A.C.

    1959-01-27

    A method is presented for thc separation of plutonium from uranium and the fission products with which it is associated. The method is based on the fact that hexavalent plutonium forms an insoluble complex precipitate with sodium acetate, as does the uranyl ion, while reduced plutonium is not precipitated by sodium acetate. Several embodiments are shown, e.g., a solution containing plutonium and uranium in the hexavalent state may be contacted with sodium acetate causing the formation of a sodium uranyl acetate precipitate which carries the plutonium values while the fission products remain in solution. If the original solution is treated with a reducing agent, so that the plutonium is reduced while the uranium remains in the hexavalent state, and sodium and acetate ions are added, the uranium will precipitutc while the plutonium remains in solution effecting separation of the Pu from urarium.

  20. Heterogeneous catalyst for the production of acetic anhydride from methyl acetate

    DOEpatents

    Ramprasad, Dorai; Waller, Francis Joseph

    1999-01-01

    This invention relates to a process for producing acetic anhydride by the reaction of methyl acetate, carbon monoxide, and hydrogen at elevated temperatures and pressures in the presence of an alkyl halide and a heterogeneous, bifunctional catalyst that contains an insoluble polymer having pendant quaternized phosphine groups, some of which phosphine groups are ionically bonded to anionic Group VIII metal complexes, the remainder of the phosphine groups being bonded to iodide. In contrast to prior art processes, no accelerator (promoter) is necessary to achieve the catalytic reaction and the products are easily separated from the catalyst by filtration. The catalyst can be recycled for consecutive runs without loss in activity. Bifunctional catalysts for use in carbonylating dimethyl ether are also provided.

  1. Heterogeneous catalyst for the production of acetic anhydride from methyl acetate

    DOEpatents

    Ramprasad, D.; Waller, F.J.

    1999-04-06

    This invention relates to a process for producing acetic anhydride by the reaction of methyl acetate, carbon monoxide, and hydrogen at elevated temperatures and pressures in the presence of an alkyl halide and a heterogeneous, bifunctional catalyst that contains an insoluble polymer having pendant quaternized phosphine groups, some of which phosphine groups are ionically bonded to anionic Group VIII metal complexes, the remainder of the phosphine groups being bonded to iodide. In contrast to prior art processes, no accelerator (promoter) is necessary to achieve the catalytic reaction and the products are easily separated from the catalyst by filtration. The catalyst can be recycled for consecutive runs without loss in activity. Bifunctional catalysts for use in carbonylating dimethyl ether are also provided.

  2. Preparation of highly pure daidzin on oligo-β-cyclodextrin-Sepharose HP and investigation of chromatographic behavior of isoflavones by molecular docking.

    PubMed

    Yang, Li; Li, Cong; Yuan, Tianhu; Tan, Tianwei; Zhang, Liqun

    2011-06-15

    A novel method using column chromatography on oligo-β-cyclodextrin-Sepharose HP for the preparation of high purity daidzin from crude soybean samples was proposed in this work. The isoflavone of daidzin in sample A and B was purified under the optimum mobile phase composed of methanol/acetic acid/water=20.0/8.0/72.0 (v/v/v) at a flow-rate of 1.0 mL/min in one-step operation with a purity of 97.2% and 98.1%, a recovery of 95.3% and 96.3% respectively. The target products in isolated fraction were detected and characterized by HPLC analysis and ESI-MS spectrum. Preparative separation with sample-load of up to 2.42 mg/mL medium gave satisfactory results for daidzin with the purities over 97% and recoveries approximately 90%. Molecular docking simulations were utilized to help demonstrate the inclusion complexation between β-cyclodextrin and the isoflavones in samples through inclusion geometries and calculations of the binding energies. The prediction of the elution orders with AUTODOCK and SURFLEX-DOCK were validated by the chromatographic results.

  3. Limits of detections for the determination of mono- and dicarboxylic acids using gas and liquid chromatographic methods coupled with mass spectrometry

    PubMed Central

    Št’ávová, Jana; Beránek, Josef; Nelson, Eric P.; Diep, Bonnie A.; Kubátová, Alena

    2011-01-01

    The chromatographic separation and instrumental limits of detection (LODs) were obtained for a broad range of C1-C18 monocarboxylic (MCAs) and C2-C14 dicarboxylic acids (DCAs) employing either chemical derivatization followed by gas chromatography-mass spectrometry and flame ionization detection (GC-MS/FID) or direct analysis with liquid chromatography high resolution MS and tandem MS (LC-MS). Suitability, efficiency and stability of reaction products for several derivatization agents used for esterification (BF3/butanol), and trimethysilylation, including trimethylsilyl-N-N-dimethylcarbamate (TMSDMC) and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) were evaluated. The lowest limits of detection for the majority of compounds below 10 pg (with the exception of acetic acid) were obtained for derivatization with BF3/butanol followed by GC-MS in the total ion current (TIC) mode. Further improvements were achieved when applying either selected ion monitoring (SIM), which decreased the LODs to 1–4 pg or a combination of SIM and TIC (SITI) (2–5 pg). GC-FID provided LODs comparable to those obtained by GC-MS TIC. Both trimethylsilylation (followed by GC-MS) and direct LC-MS/MS analysis yielded LODs of 5– 40 pg for most of the acids. For volatile acids the LODs were higher, e.g., 25 and 590 ng for TMSDMC and BSTFA derivatized formic acid, respectively whereas the LC-MS methods did not allow for the analysis of formic acid at all. PMID:21185238

  4. Chromatographic fingerprint analysis of yohimbe bark and related dietary supplements using UHPLC/UV/MS.

    PubMed

    Sun, Jianghao; Chen, Pei

    2012-03-05

    A practical ultra high-performance liquid chromatography (UHPLC) method was developed for fingerprint analysis of and determination of yohimbine in yohimbe barks and related dietary supplements. Good separation was achieved using a Waters Acquity BEH C(18) column with gradient elution using 0.1% (v/v) aqueous ammonium hydroxide and 0.1% ammonium hydroxide in methanol as the mobile phases. The study is the first reported chromatographic method that separates corynanthine from yohimbine in yohimbe bark extract. The chromatographic fingerprint analysis was applied to the analysis of 18 yohimbe commercial dietary supplement samples. Quantitation of yohimbine, the traditional method for analysis of yohimbe barks, were also performed to evaluate the results of the fingerprint analysis. Wide variability was observed in fingerprints and yohimbine content among yohimbe dietary supplement samples. For most of the dietary supplements, the yohimbine content was not consistent with the label claims.

  5. Chromatographic fingerprint analysis of Pycnogenol dietary supplements.

    PubMed

    Chen, Pei; Song, Fenhong; Lin, Long-Ze

    2009-01-01

    The bark of maritime pine (Pinus pinaster Aiton) has been widely used as a remedy for various degenerative diseases. A standard high-performance liquid chromatographic (HPLC) procedure for Pycnogenol analysis is a method specified in the United States Pharmacopeia (USP) monograph, which requires measurement of peak areas and identification of four components of the extract: caffeic acid, catechin, ferulic acid, and taxifolin. In this study, a fingerprint analysis using an HPLC method based on the USP monograph has been developed to provide additional qualitative information for the analysis of Pycnogenol-containing dietary supplements (PDS). Twelve commercially available PDS samples were purchased and analyzed along with a standard Pycnogenol extract. Their chromatographic fingerprints were analyzed using principal component analysis. The results showed that two of the samples were not consistent with the standard reference Pycnogenol extract. One contained other active ingredients in addition to Pycnogenol, and the other may have resulted from a quality control issue in manufacturing.

  6. Micro-column plasma emission liquid chromatograph

    DOEpatents

    Gay, Don D.

    1984-01-01

    In a direct current plasma emission spectrometer for use in combination with a micro-column liquid chromatograph, an improved plasma source unit. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  7. Concurrent high-performance liquid chromatographic measurement of loxapine and amoxapine and of their hydroxylated metabolites in plasma.

    PubMed

    Hüe, B; Palomba, B; Giacardy-Paty, M; Bottaï, T; Alric, R; Petit, P

    1998-06-01

    The dibenzoxazepine neuroleptic loxapine, its N-demethylated metabolite amoxapine, and their 7- and 8-hydroxymetabolites were measured simultaneously in plasma by reversed-phase high-performance chromatographic method. An original liquid-liquid extraction procedure was performed, consisting in coextraction of the substances together with a water-miscible solvent (acetonitrile) by a non-water-miscible solvent (toluene). The substances were separated on a 5-microm CN 25-cm column, and eluted with a mobile phase consisting of acetonitrile-acetic acid 0.5 N (30:70) and hexylamine (0.05%). They were detected by ultraviolet spectrophotometry at 310 nm. Clozapine was used as internal standard. Linearity was demonstrated in the range of 10 to 250 microg/l, and detection limits were found to be 3.5 to 6.3 microg/l according to the substance. Within-day repeatability ranged from 2.7% to 6.5%, and between-day reproducibility ranged from 0.9% to 20.2%. The extraction procedure provided a mean absolute recovery of 51.1% (range, 40.7% to 58.6%) with a mean coefficient of variation of 4.2%. This technique was applied to the concurrent determination of plasma concentrations of the compounds in 10 patients administered loxapine 75 to 600 mg daily. Steady state plasma levels of loxapine were significantly correlated with oral doses (n = 10, r = 0.858, p < 0.002). In conclusion, the method proved to be a convenient and reproducible procedure allowing the simultaneous measurement of loxapine, amoxapine, and their metabolites in patients.

  8. Improving Hydrocarbon Separation In Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.; Woeller, F.; Kojiro, D. R.

    1983-01-01

    Modified solica spheres enhance chromatographic separation. Commercially available silica spheres are modified by reacting them with molecules containing isocyante and isothiocyanate groups. Applications of surface derivatized spheres that result from reaction include analysis of samples prouced by atmospheric or soil probes.

  9. Tailoring orthogonal proteomic routines to understand protein separation during ion exchange chromatography.

    PubMed

    Cabrera, Rosa; Zhelyazkova, Petya; Galvis, Leonardo; Fernandez-Lahore, Marcelo

    2008-07-01

    Surface charge, molecular weight, and folding state are known to influence protein chromatographic behaviour onto ion exchangers. Experimentally, information related to such factors can be gathered via 2-DE methods. The application of 2-D PAGE under denaturing/reducing conditions was already shown to reveal separation trends within a large protein population from cell extracts. However, ion-exchange chromatography normally runs under native conditions. A tailored protocol consisting in a first separation based on IEF on Immobiline strips under native conditions followed by a second dimension SDS-PAGE run was adopted. The chromatographic versus electrophoretic separation behaviours of two model proteins, thaumatin (TAU) and BSA, were compared to better understand which proteomic routine would be better suited to anticipate IEX chromatographic separations. It was observed that the information contained in the pI value obtained with the adapted 2-DE protocol showed better correlation with the IEX chromatographic behaviour. On the other hand, chromatographic separations performed in the presence of urea as a denaturant have demonstrated the potential influence of hydrodynamic radius/conformation on protein separation. Moreover, the information provided by such 2-D system correlated well with the chromatographic behaviour of an additional set of pure proteins. An initial prediction of protein ion-exchange chromatographic behaviour could be possible utilizing an experimental approach based on 2-DE running under milder chemical conditions. This technique provides information that more closely resembles the separation behaviour observed with a complex biotechnological feedstock.

  10. Automated multiple development thin-layer chromatography for separation of opiate alkaloids and derivatives.

    PubMed

    Pothier, Jacques; Galand, Nicole

    2005-07-08

    There are three types of opiate alkaloids. First, the poppy alkaloids: morphine, codeine, thebaine, noscapine and papaverine; then, the semi-synthetic and synthetic derivatives used in therapy as antitussives and analgesics, such as pholcodine, ethylmorphine and dextromethorphan; at last narcotic compounds, diacetylmorphine (heroin) and opiates employed as substitutes in treatment of addiction: buprenorphine and methadone. For classical thin-layer chromatography (TLC) of opium alkaloids, it is necessary to use complex eluents with strong alkaline substances to obtain a clean separation between morphinan and isoquinoline compounds. This study purposes the planar chromatographic analysis of these substances by the automated multiple development (AMD) compared with results obtained by classical TLC method. The aim of this work was to achieve the best separation of these opiate alkaloids and derivatives by this modern technique of planar chromatography. The AMD system provided a clean separation for each of three opiates groups studied and the best results have been obtained with universal gradient: methanol 100, methanol-dichloromethane 50/50, dichloromethane 100, dichloromethane 100, hexane 100 for opium alkaloids and with gradient A: 5% of 28% ammonia in methanol 100, acetone 100, acetone 100, ethyl acetate-dichloromethane 50/50, dichloromethane 100 for antitussives and substitutes. Two reagents were used for the detection of alkaloids by spraying: Dragendorff and iodoplatinate reagents. The detection limits with these two reagents were 1 microg for ethylmorphine, thebaine, papaverine, codeine, and 2 microg for morphine and noscapine and other alkaloids.

  11. Development of Acetic Acid Removal Technology for the UREX+Process

    SciTech Connect

    Robert M. Counce; Jack S. Watson

    2009-06-30

    It is imperative that acetic acid is removed from a waste stream in the UREX+process so that nitric acid can be recycled and possible interference with downstreatm steps can be avoidec. Acetic acid arises from acetohydrozamic acid (AHA), and is used to suppress plutonium in the first step of the UREX+process. Later, it is hydrolyzed into hydroxyl amine nitrate and acetic acid. Many common separation technologies were examined, and solvent extraction was determined to be the best choice under process conditions. Solvents already used in the UREX+ process were then tested to determine if they would be sufficient for the removal of acetic acid. The tributyl phosphage (TBP)-dodecane diluent, used in both UREX and NPEX, was determined to be a solvent system that gave sufficient distribution coefficients for acetic acid in addition to a high separation factor from nitric acid.

  12. Pseudo-stationary separation materials for highly parallel separations.

    SciTech Connect

    Singh, Anup K.; Palmer, Christopher

    2005-05-01

    Goal of this study was to develop and characterize novel polymeric materials as pseudostationary phases in electrokinetic chromatography. Fundamental studies have characterized the chromatographic selectivity of the materials as a function of chemical structure and molecular conformation. The selectivities of the polymers has been studied extensively, resulting in a large body of fundamental knowledge regarding the performance and selectivity of polymeric pseudostationary phases. Two polymers have also been used for amino acid and peptide separations, and with laser induced fluorescence detection. The polymers performed well for the separation of derivatized amino acids, and provided some significant differences in selectivity relative to a commonly used micellar pseudostationary phase. The polymers did not perform well for peptide separations. The polymers were compatible with laser induced fluorescence detection, indicating that they should also be compatible with chip-based separations.

  13. Chromatographic resolution of a salt into its parent acid and base constituents.

    PubMed

    Davankov, Vadim; Tsyurupa, Maria

    2006-12-08

    Based on the results of the earlier proposed process of separation of mixtures of mineral electrolytes by size-exclusion chromatography (SEC), it has been suggested that a mineral salt must spontaneously resolve, at least partially, into its parent acid and base constituents, provided that the separating media discriminates the anion and cation of the salt according to their size. Indeed, migration of a zone of an aqueous salt solution through a bed of neutral nanoporous hypercrosslinked polystyrene-type packing was shown to result in the generation of acidic and alkaline effluent fractions. The principle of spontaneous salt resolution has been extended to other types of discriminating interactions between the stationary phase and the two ions of the salt. The idea was exemplified by the resolution of ammonium acetate, due to hydrophobic retention of the acetate, into fractions enriched in ammoniac and then acetic acid.

  14. Electromigration of a heteroconjugated imidazole-acetate complex in ACN.

    PubMed

    Porras, Simo P; Jussila, Matti

    2007-10-01

    ACN is an extremely poor hydrogen bond donor and therefore the anions dissolved in it are solvated mainly by other hydrogen bond donors (e.g. uncharged acids) possibly present in the solution. Under properly selected experimental conditions stabilization via hydrogen bonding can be used for separation in CE as has been demonstrated for uncharged acids by several authors. Electromigration based on heteroconjugation can be of importance, e.g. when aqueous separation medium cannot be used due to stability reasons. It also allows CE to be used as a tool for solution chemistry measurements, if the required physicochemical properties of the studied system are known or they can be predicted with sufficient accuracy by existing theories. In the present work we showed that also an uncharged base can stabilize an anion via hydrogen bonding in ACN. In the setup imidazole was chosen as a model base and acetate ion as complexing anion in equimolar acetic acid-acetate buffer. The resulted hydrogen-bonded imidazole-acetate complex (i.e. heteroconjugate) possesses a charge and can thus migrate in CE. It was shown that the studied complexation in ACN is sensitive to competition by other hydrogen bond donors such as water and methanol. On the other hand, acetone, which is a poor hydrogen bond donor, did not have much effect on the complexation. To take the effect of ionic strength on mobility into account, mobilities of the imidazole-acetate complex measured at various ionic strengths were corrected to zero ionic strength by the aid of conductivity equation. A fit of the 1:1 binding isotherm to the ionic strength corrected mobility versus acetate concentration data led to rather good correlation. However, x-reciprocal linear transformation of the binding isotherm showed nonlinearity, which could be partly explained by homoconjugation of acetic acid and acetate ion. Since the homoconjugation constant for acetic acid under present experimental conditions was not available, theoretical

  15. Separated Shoulder

    MedlinePlus

    Separated shoulder Overview By Mayo Clinic Staff A separated shoulder is an injury to the ligaments that hold your collarbone (clavicle) to your shoulder blade. In a mild separated shoulder, the ligaments ...

  16. Myo-inositol esters of indole-3-acetic acid are endogenous components of Zea mays L. shoot tissue

    NASA Technical Reports Server (NTRS)

    Chisnell, J. R.

    1984-01-01

    Indole-3-acetyl-myo-inositol esters have been demonstrated to be endogenous components of etiolated Zea mays shoots tissue. This was accomplished by comparison of the putative compounds with authentic, synthetic esters. The properties compared were liquid and gas-liquid chromatographic retention times and the 70-ev mass spectral fragmentation pattern of the pentaacetyl derivative. The amount of indole-3-acetyl-myo-inositol esters in the shoots was determined to be 74 nanomoles per kilogram fresh weight as measured by isotope dilution, accounting for 19% of the ester indole-3-acetic acid of the shoot. This work is the first characterization of an ester conjugate of indole-3-acetate acid from vegetative shoot tissue using multiple chromatographic properties and mass spectral identification. The kernel and the seedling shoot both contain indole-3-acetyl-myo-inositol esters, and these esters comprise approximately the same percentage of the total ester content of the kernel and of the shoot.

  17. Evolution of strategies to achieve baseline separation of ten anionic, water-soluble sulfated estrogens via achiral packed column supercritical fluid chromatography.

    PubMed

    Patel, M A; Hardink, M A; Wrisely, L; Riley, F W; Hudalla, C J; Ashraf-Khorassani, M; Taylor, L T

    2014-11-28

    Near baseline separation of ten sulfated sodium salts of various structurally related estrogens employing a variety of bonded stationary phase packed columns was obtained using a conventional supercritical fluid chromatograph coupled with UV detection. Critical pairs 2/3 (8,9-dehydroestrone/17β-dihydroequilin) and 6/7 (17α-estradiol or 17α-dihydroequilin/estrone), however, failed to baseline separate. In all preliminary separations, 10mM ammonium acetate and variable percentages of H2O were initially used as co-additives in conjunction with methanol as a modifier. Different modifier programs and temperatures were employed to optimize the separation in a timely manner. A 2-ethylpyridine column provided the best separation compared to bare silica, diol, and cyano-based bonded phase columns. The employment of both salt and water as additives to the methanol-modified CO2 mobile phase suggested a mixed mode separation mechanism involving both ion pairing of each anionic sulfated estrogen with ammonium ion and hydrophilic interaction facilitated by partitioning of analyte between the aqueous solvated stationary phase and the aqueous component of the mobile phase. Upon more extensive study with either iso-propylamine or formic acid-ammonium formate buffer, the critical anionic pairs were 95% baseline resolved.

  18. Chiral separation of agricultural fungicides.

    PubMed

    Pérez-Fernández, Virginia; García, Maria Ángeles; Marina, Maria Luisa

    2011-09-23

    Fungicides are very important and diverse environmental and agricultural concern species. Their determination in commercial formulations or environmental matrices, requires highly efficient, selective and sensitive methods. A significant number of these chemicals are chiral with the activity residing usually in one of the enantiomers. The different toxicological and degradation behavior observed in many cases for fungicide enantiomers, results in the need to investigate them separately. For this purpose, separation techniques such as GC, HPLC, supercritical fluid chromatography (SFC) and CE have widely been employed although, at present, HPLC still dominates chromatographic chiral analysis of fungicides. This review covers the literature concerning the enantiomeric separation of fungicides usually employed in agriculture grouping the chiral separation methodologies developed for their analysis in environmental, biological, and food samples.

  19. Liquid chromatographic analysis of oxytocin and its related substances.

    PubMed

    Ashenafi, Dunge; Van Hemelrijck, Elise; Chopra, Shruti; Hoogmartens, Jos; Adams, Erwin

    2010-01-05

    A selective gradient liquid chromatographic (LC) method for the determination of oxytocin (OT) and its related substances in bulk drugs has been developed. The method uses a reversed-phase C18 column (25 cm x 4.0 mm i.d.), 5 microm kept at 40 degrees C. The mobile phases consist of acetonitrile, dihydrogen phosphate solution pH 4.4 and water. The flow rate is 1.0 ml/min. UV detection is performed at 220 nm. A system suitability test (SST) was developed to govern the quality of the separation. The separation towards OT components was investigated on different C18 columns. The developed method was further validated with respect to robustness, precision, sensitivity and linearity. A central composite design was applied to examine the robustness of the method. The method shows good precision, sensitivity, linearity and robustness. Two commercial OT samples were examined using this method. Furthermore, the method proved to be successful when applied to analyze a marketed OT formulation for injection.

  20. Improving the productivity of a multidimensional chromatographic preparative system by collecting pure chemicals after each of three chromatographic dimensions.

    PubMed

    Sciarrone, Danilo; Pantò, Sebastiano; Donato, Paola; Mondello, Luigi

    2016-12-02

    The enhanced sample collection capability of a heart-cutting three-dimensional GC-prep system is reported. In its original configuration, a highly pure component can be usually collected after the last (3D) column outlet by means of a dedicated preparative station. The latter is located after the last chromatographic column, and this poses the requirement for multiple heart cuts even for those components showing satisfactory degree of purity after the first (or second) separation dimension. The feasibility to collect pure components after each chromatographic dimension is here described, employing a three-dimension MDGC system equipped with high-temperature valves, located inside the first and second GC ovens, with the aim to improve the productivity of the collection procedure. In addition to a commercial preparative collector located at the 3D outlet, two laboratory-made collection systems were applied in the first and second dimension, reached by the effluent to be collected trough a high-temperature valve switching the heart-cut fraction between either the detector (FID), or the collector. Highly pure sesquiterpene components were collected, namely: patchouli alcohol after the first column [poly(5% diphenyl/95% dimethylsiloxane)], α-bulnesene after a second column coated with high molecular weight polyethylene glycol, and α-guaiene after an ionic-liquid based column (SLB-IL60), used as the third dimension. Purity levels ranging from 85 to 95% were achieved with an average collection recovery of 90% (n=5). The following average amounts were collected per run: 160μg for α-guaiene, 295μg for α-bulnesene, and 496μg for patchouli alcohol.

  1. Organic contaminant separator

    DOEpatents

    Del Mar, Peter; Hemberger, Barbara J.

    1991-01-01

    A process of sample preparation prior to analysis for the concentration of an organic contaminant in an aqueous medium by (a) passing an initial aqueous medium including a minor amount of the organic contaminant through a polyolefin tube having an internal diameter of from about 0.01 to about 2.0 millimeters and being of sufficient length to permit the organic contaminant to adhere to the tube, (b) passing a solvent through the tube, said solvent capable of separating the adhered organic contaminant from the tube. Further, a chromatographic apparatus for sample preparation prior to analysis for the concentration of an organic contaminant in an aqueous medium, said apparatus including a polyolefin tube having an internal diameter of from about 0.01 to about 2.0 millimeters and being of sufficient length to permit an organic contaminant contained within an aqueous medium passed therethrough to adhere to the tube is disclosed.

  2. PLUTONIUM SEPARATION METHOD

    DOEpatents

    Beaufait, L.J. Jr.; Stevenson, F.R.; Rollefson, G.K.

    1958-11-18

    The recovery of plutonium ions from neutron irradiated uranium can be accomplished by bufferlng an aqueous solutlon of the irradiated materials containing tetravalent plutonium to a pH of 4 to 7, adding sufficient acetate to the solution to complex the uranyl present, adding ferric nitrate to form a colloid of ferric hydroxide, plutonlum, and associated fission products, removing and dissolving the colloid in aqueous nitric acid, oxldizlng the plutonium to the hexavalent state by adding permanganate or dichromate, treating the resultant solution with ferric nitrate to form a colloid of ferric hydroxide and associated fission products, and separating the colloid from the plutonlum left in solution.

  3. URANIUM SEPARATION PROCESS

    DOEpatents

    Hyde, E.K.; Katzin, L.I.; Wolf, M.J.

    1959-07-14

    The separation of uranium from a mixture of uranium and thorium by organic solvent extraction from an aqueous solution is described. The uranium is separrted from an aqueous mixture of uranium and thorium nitrates 3 N in nitric acid and containing salting out agents such as ammonium nitrate, so as to bring ihe total nitrate ion concentration to a maximum of about 8 N by contacting the mixture with an immiscible aliphatic oxygen containing organic solvent such as diethyl carbinol, hexone, n-amyl acetate and the like. The uranium values may be recovered from the organic phase by back extraction with water.

  4. High pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, Christian G.; Sakaji, Richard H.

    1985-01-01

    A gradient mixer which effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum "band-broadening".

  5. High-pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, C.G.; Sakaji, R.H.

    1982-09-08

    A gradient mixer effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum band-broadening.

  6. Novel applications of continuous annular chromatography: Separation of sugars

    SciTech Connect

    Howard, A.J.; Carta, G.; Byers, C.H.

    1987-01-01

    Continuous chromatographic separations of fructose-glucose-sucrose mixtures have been investigated experimentally in a laboratory-scale continuous annular chromatograph using Ca-exchanged Dowex 50W-X8 resin as adsorbent. Comparative chromatographic separation studies have also been conducted for the system using a conventional fixed-bed column packed with the same resin. Complete resolution of fructose-glucose mixtures could be obtained both in a 60 cm-long continuous annular chromatograph and in a conventional column of the same length with sugars feed concentration up to 200 g/L. In the four-component mixture blue dextran (higher molecular weight saccharide), sucrose, glucose and fructose complete rsolution of all species except sucrose-glucose under the relatively mild separating conditions tested. The experimental results have been analyzed in terms of approximate linear chromatographic theories for fixed and rotating beds. Bed properties and equilibrium and mass transfer parameters used in the model were obtained through independent experiments. With these parameters a good fit to the experimental results was obtained. Differences in feed mixtures and dispersion characteristics contribute to the minor offset between fixed bed and continuous chromatograph results. 21 refs., 12 figs., 3 tabs.

  7. Chromatographic behaviour of alkaloids on thin layers of anion and cation exhangers. I. AG 1-X4 and cellex D.

    PubMed

    Lepri, L; Desideri, P G; Lepori, M

    1976-01-07

    The chromatographic behaviour of 48 alkaloids has been studied on Bio-Rad AG 1-X4, Cellex D and microcrystalline cellulose, eluting with solutions of different pH but constant ionic strength (0.5). Many interesting separations were effected on both AG 1-X4 and Cellex D layers. The influence of pH on the chromatographic behaviour of alkaloids has been quantitatively studied and an equation was used that expresses the behaviour of the alkaloids on both AG 1-X4 (AcO-) and microcrystalling cellulose layers. The nonapplicability of this equation to Cellex D layers is discussed.

  8. Investigation on enantiomeric separations of fluorenylmethoxycarbonyl amino acids and peptides by high-performance liquid chromatography using native cyclodextrins as chiral stationary phases.

    PubMed

    Tang, Y; Zukowski, J; Armstrong, D W

    1996-09-06

    A systematic study was carried out to investigate enantiomeric separations of fluorenylmethoxycarbonyl (FMOC) amino acids and their peptides. Twenty amino acids were derivatized by 9-fluorenylmethyl chloroformate (FMOC-Cl) and its analogues, FMOC-glycyl-Cl and FMOC-beta-alanyl-Cl. All derivatives were chromatographed on native beta- and gamma-cyclodextrin columns using acetonitrile as the main mobile phase component. The results indicated that glycyl and beta-alanyl groups between FMOC and amino acid moieties enhanced chiral selectivities of amino acid derivatives. The addition of modifiers, triethylamine, acetic acid and methanol, into the mobile phase caused alterations in retention, enantiorecognition and elution order. The structures of amino acids and the type of chiral stationary phase employed exhibited significant impacts on chiral resolutions. It is also found that the number and position of glycyl moieties affect the retentions and enantioselectivities of FMOC derivatized glycyl containing peptides.

  9. Development of a validated RP-LC/ESI-MS-MS method for separation, identification and determination of related substances of tamsulosin in bulk drugs and formulations.

    PubMed

    Nageswara Rao, R; Kumar Talluri, M V N; Narasa Raju, A; Shinde, Dhananjay D; Ramanjaneyulu, G S

    2008-01-07

    A reversed-phase high performance liquid chromatographic (RP-HPLC) method for evaluation of purity of tamsulosin in bulk drugs and pharmaceuticals was developed. The separation was accomplished on an Inertsil C(18) column using 10 mM ammonium acetate: acetonitrile as a mobile phase in a gradient elution mode. A photodiode array detector set at 280 nm was used for detection. The impurities were identified by ESI-MS-MS. The detection limits were 0.06-0.11 microg/ml. The method was validated with respect to accuracy, precision, linearity, ruggedness and limits of detection and quantification. It finds application not only for monitoring the reactions during the process development but also on quality assurance of tamsulosin.

  10. Displacement separations by continuous annular chromatography

    SciTech Connect

    DeCarli, J.P. II; Carta, G. ); Byers, C.H. . Chemical Technology Div.)

    1988-01-01

    Continuous annular chromatography (CAC) has been introduced as an effective means of carrying out chromatographic separations in a truly continuous manner. Process applications have been demonstrated. In this work the authors demonstrate how CAC can be operated for displacement development separations. In this mode of operation of the apparatus separation and concentration of multicomponent mixtures can be obtained simultaneously and continuously. Experimental results and model simulations for this novel separation device are presented along with a comparison of different modes of operation and a discussion of industrial applications.

  11. Acetate fuels the cancer engine.

    PubMed

    Lyssiotis, Costas A; Cantley, Lewis C

    2014-12-18

    Cancer cells have distinctive nutrient demands to fuel growth and proliferation, including the disproportionate use of glucose, glutamine, and fatty acids. Comerford et al. and Mashimo et al. now demonstrate that several types of cancer are avid consumers of acetate, which facilitates macromolecular biosynthesis and histone modification.

  12. Evaluation of selectivity in homologous multimodal chromatographic systems using in silico designed antibody fragment libraries.

    PubMed

    Karkov, Hanne Sophie; Woo, James; Krogh, Berit Olsen; Ahmadian, Haleh; Cramer, Steven M

    2015-12-24

    This study describes the in silico design, surface property analyses, production and chromatographic evaluations of a diverse set of antibody Fab fragment variants. Based on previous findings, we hypothesized that the complementarity-determining regions (CDRs) constitute important binding sites for multimodal chromatographic ligands. Given that antibodies are highly diversified molecules and in particular the CDRs, we set out to examine the generality of this result. For this purpose, four different Fab fragments with different CDRs and/or framework regions of the variable domains were identified and related variants were designed in silico. The four Fab variant libraries were subsequently generated by site-directed mutagenesis and produced by recombinant expression and affinity purification to enable examination of their chromatographic retention behavior. The effects of geometric re-arrangement of the functional moieties on the multimodal resin ligands were also investigated with respect to Fab variant retention profiles by comparing two commercially available multimodal cation-exchange ligands, Capto MMC and Nuvia cPrime, and two novel multimodal ligand prototypes. Interestingly, the chromatographic data demonstrated distinct selectivity trends between the four Fab variant libraries. For three of the Fab libraries, the CDR regions appeared as major binding sites for all multimodal ligands. In contrast, the fourth Fab library displayed a distinctly different chromatographic behavior, where Nuvia cPrime and related multimodal ligand prototypes provided markedly improved selectivity over Capto MMC. Clearly, the results illustrate that the discriminating power of multimodal ligands differs between different Fab fragments. The results are promising indications that multimodal chromatography using the appropriate multimodal ligands can be employed in downstream bioprocessing for challenging selective separation of product related variants.

  13. Separation of Albumin, Ceruloplasmin, and Transferrin from Human Plasma.

    ERIC Educational Resources Information Center

    Barnes, Grady; Frieden, Earl

    1982-01-01

    Procedures are provided for separating the principal metalloproteins (albumin, ceruloplasmin, and transferrin) from plasma using column chromatographic techniques. The experiment can be completed in two separate three-hour laboratory periods during which column chromatography is illustrated and the effect of pH on charge and affinity of a protein…

  14. Origins of blood acetate in the rat.

    PubMed Central

    Buckley, B M; Williamson, D H

    1977-01-01

    A novel enzymimc cycling assay for the determination of acetate in biological material is described. Measurements of the acetate concentration in blood and liver samples from rats of various ages and nutritional states with this assay are reported. The contribution of the intestine, the liver and the rest of the body to maintaining the concentration of acetate in the circulation is examined. Evidence is presented that the gut flora constitute the main source of acetate in blood of fed adult rats, though endogenous production of acetate is of significance in other situations. The streptozotocin-diabetic rat has an elevated blood acetate concentration. PMID:597244

  15. Gas chromatograph-combustion system for 14C-accelerator mass spectrometry.

    PubMed

    McIntyre, Cameron P; Sylva, Sean P; Roberts, Mark L

    2009-08-01

    A gas chromatograph-combustion (GC-C) system is described for the introduction of samples as CO(2) gas into a (14)C accelerator mass spectrometry (AMS) system with a microwave-plasma gas ion source. Samples are injected into a gas chromatograph fitted with a megabore capillary column that uses H(2) as the carrier gas. The gas stream from the outlet of the column is mixed with O(2) and Ar gas and passed through a combustion furnace where the H(2) carrier gas and separated components are quantitatively oxidized to CO(2) and H(2)O. Water vapor is removed using a heated nafion dryer. The Ar carries the CO(2) to the ion source. The system is able to separate and oxidize up to 10 microg of compound and transfer the products from 7.6 mL/min of H(2) carrier gas into 0.2-1.0 mL/min of Ar carrier gas. Chromatographic performance and isotopic fidelity satisfy the requirements of the (14)C-AMS system for natural abundance measurements. The system is a significant technical advance for GC-AMS and may be capable of providing an increase in sensitivity for other analytical systems such as an isotope-ratio-monitoring GC/MS.

  16. Ultracapacitor separator

    DOEpatents

    Wei, Chang; Jerabek, Elihu Calvin; LeBlanc, Jr., Oliver Harris

    2001-03-06

    An ultracapacitor includes two solid, nonporous current collectors, two porous electrodes separating the collectors, a porous separator between the electrodes and an electrolyte occupying the pores in the electrodes and separator. The electrolyte is a polar aprotic organic solvent and a salt. The porous separator comprises a wet laid cellulosic material.

  17. A stability-indicating HPLC method to determine cyproterone acetate in tablet formulations.

    PubMed

    Segall, A; Vitale, M; Perez, V; Hormaechea, F; Palacios, M; Pizzorno, M T

    2000-08-01

    A simple and accurate liquid chromatographic method was developed to estimate cyproterone acetate (CA) in pharmaceuticals. The drug was chromatographed on a reversed-phase C18 column. Eluents were monitored at a wavelength of 254 nm utilizing a mixture (60:40) of acetonitrile and water. Solution concentrations were measured on a weight basis to avoid the use of an internal standard. The method was statistically validated for linearity, accuracy, precision, and selectivity. Due to its simplicity and accuracy, we believe that the method can be used for routine quality control analysis. No specific sample preparation is required except for the use of a column guard and a suitable prefilter attached to the syringe.

  18. High-performance liquid chromatographic determination of benzalkonium and naphazoline or tetrahydrozoline in nasal and ophthalmic solutions.

    PubMed

    Santoni, G; Medica, A; Gratteri, P; Furlanetto, S; Pinzauti, S

    1994-11-01

    A high-performance liquid chromatographic method is described for the determination of benzalkonium chloride homologues and naphazoline nitrate or tetrahydrozoline hydrochloride in ophthalmic and nasal solutions. The technique involves a one-step dilution (1:5) for sample preparation and direct injection onto a 5 mm RP C-8 column. The mobile phase is acetonitrile-diluted acetic acid (80:20, v/v) with 6 mM tetramethylammonium bromide. Detection is carried out at 260 nm with a diode array. The method is rapid, specific, reproducible and is especially useful for quality control procedures.

  19. Optimization and Assessment of Three Different High Performance Liquid Chromatographic Systems for the Combinative Fingerprint Analysis and Multi-Ingredients Quantification of Sangju Ganmao Tablet.

    PubMed

    Guo, Meng-Zhe; Han, Jie; He, Dan-Dan; Zou, Jia-Hui; Li, Zheng; Du, Yan; Tang, Dao-Quan

    2017-03-01

    Chromatographic separation is still a critical subject for the quality control of traditional Chinese medicine. In this study, three different high performance liquid chromatographic (HPLC) systems employing commercially available columns packed with 1.8, 3.5 and 5.0 μm particles were respectively developed and optimized for the combinative fingerprint analysis and multi-ingredients quantification of Sangju Ganmao tablet (SGT). Chromatographic parameters including the repeatability of retention time and peak area, symmetry factor, resolution, number of theoretical plates and peak capacity were used to assess the chromatographic performance of different HPLC systems. The optimal chromatographic system using Agilent ZORBAX SB-C18 column (2.1 mm × 100 mm, 3.5 μm) as stationary phase was respectively coupled with diode array detector or mass spectrometry detector for the chromatographic fingerprint analysis and simultaneous quantification or identification of nine compounds of SGT. All the validation data conformed to the acceptable requirements. For the fingerprint analysis, 31 peaks were selected as the common peaks to evaluate the similarities of SGT from 10 different manufacturers using heatmap, hierarchical cluster analysis and principal component analysis. The results demonstrated that the combinations of the quantitative and chromatographic fingerprint analysis offer an efficient way to evaluate the quality consistency of SGT.

  20. Simultaneous determination of scopoletin, psoralen, bergapten, xanthotoxin, columbianetin acetate, imperatorin, osthole and isoimperatorin in rat plasma by LC-MS/MS for pharmacokinetic studies following oral administration of Radix Angelicae Pubescentis extract.

    PubMed

    Chang, Yan-xu; Zhang, Qiu-Hong; Li, Jin; Zhang, Ling; Guo, Xin-rong; He, Jun; Zhang, Peng; Ma, Lin; Deng, Yan-ru; Zhang, Bo-li; Gao, Xiu-mei

    2013-04-15

    A rapid and sensitive bioassay based on liquid chromatography tandem mass spectrometry (LC-MS/MS) has been developed and validated for the simultaneous determination of eight coumarins in rat plasma. The liquid-liquid extraction method with ethyl acetate was used to prepare the plasma samples after addition of warfarin as an internal standard (IS). Chromatographic separation was performed on an Eclipse plus C18 column (100mm×4.6mm, 1.8μm) using gradient elution when 1mM ammonium acetate aqueous solution - acetonitrile was used as the mobile phase. The lower limit of quantitation (LLOQ) of each coumarin was lower than 2.16ngmL(-1). Intra-day and inter-day precisions were less than 15%. The accuracies were in the range of 88.9-117%. The mean recoveries of coumarins and IS were higher than 84%. The method was successfully applied to a pharmacokinetic study of eight coumarins in rats after oral administration of radix angelicae pubescentis.

  1. Gas chromatographic-mass spectrometric analysis of volatile amines produced by several strains of Clostridium.

    PubMed

    Pons, J L; Rimbault, A; Darbord, J C; Leluan, G

    1985-02-08

    A gas chromatographic--mass spectrometric technique is proposed for the analysis of volatile amines which were isolated from Clostridium cultures by vacuum distillation and concentrated as hydrochloride salts. Headspace sampling after alkalinization of the salts under vacuum was the most suitable for subsequent gas chromatographic analysis. With ammonia-loaded helium as carrier gas, methylamines were separated on 4.8% PEG 2OM + 0.3% potassium hydroxide on Carbopack B, and other volatile amines on 28% Pennwalt 223 + 4% potassium hydroxide on Gas-Chrom R. Bacterial volatile amines (dimethylamine, trimethylamine, isobutylamine, 3-methylbutylamine, etc.) were detected with a flame-ionization detector and identified by gas chromatography--mass spectrometry in electron-impact and chemical ionization modes.

  2. A novel chromatographic method allows on-line reanalysis of the proteome.

    PubMed

    Waanders, Leonie F; Almeida, Reinaldo; Prosser, Simon; Cox, Jürgen; Eikel, Daniel; Allen, Mark H; Schultz, Gary A; Mann, Matthias

    2008-08-01

    Liquid chromatography combined with electrospray ionization is widely used for direct analysis of polar and labile molecules by LCMS. The on-line coupling in LCMS is a major strength but also causes a principal limitation that each eluting analyte has to be analyzed immediately and is not available for detailed interrogation after the LCMS run. Here we developed a new chromatographic strategy, which removes this limitation. After column separation the flow is split, one portion is analyzed directly, and the other is diverted to a capture capillary. After the direct LCMS run, the flow is switched, and the portion stored in the capillary is analyzed ("replay run"). We describe a setup consisting of an analytical column, a splitting valve, and a focusing column, which performs at full sensitivity and undiminished chromatographic resolution. We demonstrate three principal advantages of this system: nearly continuous MS utilization, duplicate analysis without requirement for additional sample, and targeting of important but undersampled features in the replay run.

  3. Systematic toxicological analysis of drugs and poisons in biosamples by hyphenated chromatographic and spectroscopic techniques.

    PubMed

    Polettini, A

    1999-10-15

    The introduction of hyphenated chromatographic-spectroscopic techniques represented a substantial step-forward for Systematic Toxicological Analysis (STA), increasing the amount and quality of information obtainable from the analysis of a biological sample, and enhancing the possibilities of identifying unknown drugs and poisons. STA methods based either on GC-MS or on HPLC-UV published in the last decade are reviewed in this paper. The different analytical phases, i.e. sample preparation (pretreatment, extraction, derivatisation), chromatographic separation and detection/identification are examined in detail in order to emphasise the complementarity of the two approaches. In addition, the first STA method based on HPLC-MS is illustrated and some applications of TLC-UV to drug screening are also described. Finally, an overview of semi- and fully-automated STA methods is given.

  4. Highly sensitive gas chromatographic determination of ethanol in human urine samples.

    PubMed

    Zilly, Michael; Langmann, Peter; Lenker, Ulrike; Satzinger, Verena; Schirmer, Diana; Klinker, Hartwig

    2003-12-25

    In order to evaluate recent alcohol consumption, a very sensitive and specific gas chromatographic method for ethanol determination in human urine samples was developed. The non-invasive method was performed without any pretreatment and carried out on a Stabilwax capillary column, 30 m x 0.53 mm x 1.0 microm film thickness. Helium was used as carrier gas with a constant inlet pressure of 27.72 kPa (0.277 bar) and a flame ionization detector (FID). Quantification was performed with the use of acetonitrile as an internal standard (IS). The calibration curve was linear throughout the concentration range from 0.5 to 500 mg/l. The calculated intra- and inter-day coefficients of variation were below 8%. A clear chromatographic separation of ethanol from methanol, acetone, 1-propanol and 2-propanol was achieved.

  5. Electrospun cellulose acetate-garnet nanocomposite magnetic fibers for bioseparations.

    PubMed

    Munaweera, Imalka; Aliev, Ali; Balkus, Kenneth J

    2014-01-08

    Cellulose acetate fibers with magnetic properties have recently attracted much attention because of their potential novel applications in biomedicine such as for cell and protein separations, magnetic resonance imaging contrast agents, and magnetic filters. In this work, as synthesized yttrium iron garnet and gadolinium substituted yttrium iron garnet nanoparticles have been used to generate magnetic filter paper. Garnet nanoparticles dispersed in cellulose acetate polymer solutions were electrospun as free-standing nonwoven fiber mats as well as on cellulose filter paper substrates resulting in magnetic filter papers. The magnetic fibers were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM), powder X-ray diffraction (PXRD), and superconducting quantum interference device (SQUID) magnetic property measurements. The resulting magnetic polymer nanocomposites can be easily picked up by an external magnet from a liquid medium. Fluorescein isothiocyanate (FITC) labeled bovine serum albumin (BSA) was separated from solution by using the magnetic filter paper.

  6. Ozone decomposition in aqueous acetate solutions

    SciTech Connect

    Sehested, K.; Holcman, J.; Bjergbakke, E.; Hart, E.J.

    1987-01-01

    The acetate radical ion reacts with ozone with a rate constant of k = (1.5 +/- 0.5) x 10Z dmT mol s . The products from this reaction are CO2, HCHO, and O2 . By subsequent reaction of the peroxy radical with ozone the acetate radical ion is regenerated through the OH radical. A chain decomposition of ozone takes place. It terminates when the acetate radical ion reacts with oxygen forming the unreactive peroxy acetate radical. The chain is rather short as oxygen is developed, as a result of the ozone consumption. The inhibiting effect of acetate on the ozone decay is rationalized by OH scavenging by acetate and successive reaction of the acetate radical ion with oxygen. Some products from the bimolecular disappearance of the peroxy acetate radicals, however, react further with ozone, reducing the effectiveness of the stabilization.

  7. Rapid electrophoresis and quantitation of haemoglobins on cellulose acetate

    PubMed Central

    Marengo-Rowe, A. J.

    1965-01-01

    A rapid and reproducible electrophoretic method for the separation and quantitation of haemoglobins on cellulose acetate is described. The accuracy of the method and its possible sources of error are discussed. The normal range for haemoglobin A2 by this method is 1% to 3% of the total haemoglobin concentration. Blood samples from 32 thalassaemic patients showed haemoglobin A2 values of 3·5% to 7%. Images PMID:5844210

  8. [Chiral separation of five beta-blockers using di-n-hexyl L-tartrate-boric acid complex as mobile phase additive by reversed-phase liquid chromatography].

    PubMed

    Yang, Juan; Wang, Lijuan; Guo, Qiaoling; Yang, Gengliang

    2012-03-01

    A reversed-phase high performance liquid chromatographic (HPLC) method using the di-n-hexyl L-tartrate-boric acid complex as a chiral mobile phase additive was developed for the enantioseparation of five beta-blockers including propranolol, esmolol, metoprolol, bisoprolol and sotalol. In order to obtain a better enantioseparation, the influences of concentrations of di-n-butyl L-tartrate and boric acid, the type, concentration and pH of the buffer, methanol content as well as the molecular structure of analytes were extensively investigated. The separation of the analytes was performed on a Venusil MP-C18 column (250 mm x 4.6 mm, 5 microm). The mobile phase was 15 mmol/L ammonium acetate-methanol containing 60 mmol/L boric acid, 70 mmol/L di-n-hexyl L-tartrate (pH 6.00). The volume ratios of 15 mmol/L ammonium acetate to methanol were 20: 80 for propranolol, esmolol, metoprolol, bisoprolol and 30: 70 for sotalol. The flow rate was 0.5 mL/min and the detection wavelength was set at 214 nm. Under the optimized conditions, baseline enantioseparation was obtained separately for the five pairs of analytes.

  9. Gas chromatographic determination of polysaccharide gums in foods after hydrolysis and derivatization.

    PubMed

    Lawrence, J F; Iyengar, J R

    1985-12-20

    A gas chromatographic method was evaluated for the determination of food grade gums in dairy products, salad dressings and meat sauces. The gums studied were tragacanth, karaya, ghatti, carob, guar, arabic and xanthan gum. The extraction method included removal of fat followed by starch degradation then precipitation of protein. The isolated gums were hydrolysed with trifluoroacetic acid and the resulting neutral monosaccharides converted to their aldonitrile acetate derivatives for determination by gas chromatography. Recoveries from thirteen different commodities averaged 85%. However, the recovery of guar gum from ice cream and cold pack cheese was 42 and 50%, respectively. In a comparison of enzyme hydrolysis and iodine complexation for the removal of starch the former was simpler and provided cleaner extracts than the iodine treatment. Both gave similar results.

  10. Ion chromatographic analysis of amines, alkanolamines, and associated anions in concrete.

    PubMed

    Page, Mary M; Page, Christopher L; Shaw, Stuart J; Sawada, Shohei

    2005-03-01

    In order to assess the effectiveness of applying penetrating corrosion inhibitors to the surface of reinforced concrete, it is necessary to devise accurate methods for their detection and quantification. In this paper, methods for ion chromatographic analysis of a variety of amines, alkanolamines, and associated anions, which may be used as corrosion inhibitors for steel reinforcement in concrete, are described. By careful adjustment of the conditions for analysis, these inhibitors were readily identified and quantified in concrete/cement pore solutions or digests. Characterisation of the cationic inhibitors, ethanolamine, quaternary methylammonium, dimethylethanolamine, cyclohexylamine, guanidine, and arginine, and the anionic inhibitors, nitrite, molybdate, acetate, benzoate, and azelate, was carried out conductimetrically. To enhance the sensitivity of detection, amperometry was used for the analysis of triethanolamine and low concentrations of ethanolamine. Ion chromatography was also used as a means of obtaining a distribution profile of the concentrations of inhibitor ions present throughout a concrete structure.

  11. 21 CFR 184.1721 - Sodium acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Sodium acetate. 184.1721 Section 184.1721 Food and....1721 Sodium acetate. (a) Sodium acetate (C2H3O2Na, CAS Reg. No. 127-09-3 or C2H3O2Na·3H2O, CAS Reg. No. 6131-90-4) is the sodium salt of acetic acid and occurs naturally in plant and animal tissues....

  12. Application and recovery of ionic liquids in the preparative separation of four flavonoids from Rhodiola rosea by on-line three-dimensional liquid chromatography.

    PubMed

    Ma, Shufeng; Hu, Liming; Ma, Chaoyang; Lv, Wenping; Wang, Hongxin

    2014-09-01

    A novel on-line three-dimensional liquid chromatography method was developed to separate four main flavonoids from Rhodiola rosea. Ethyl acetate/0.5 mol/L ionic liquid 1-butyl-3-methylimidazolium chloride aqueous solution was selected as the solvent system. In the first-dimension separation, the target flavonoids were entrapped and subsequently desorbed into the second-dimension high-speed countercurrent chromatographic column for separation. In the third-dimension chromatography, the residual ionic liquid in the four separated flavonoids was removed and the used ionic liquid was recovered. As a result, 35.1 mg of compound 1, 20.4 mg of compound 2, 8.5 mg of compound 3, and 10.6 mg of compound 4 were obtained from 1.53 g R. rosea extract. They were identified as rhodiosin, rhodionin, herbacetin, and kaempferol, respectively. The recovery of ionic liquid reached 99.1% of the initial amount. The results showed that this method is a powerful technology for the separation of R. rosea flavonoids and that the ionic-liquid-based solvent system has advantages over traditional solvent systems in renewable and environmentally friendly properties.

  13. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  14. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  15. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  16. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  17. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  18. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  19. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  20. 21 CFR 184.1005 - Acetic acid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acetic acid. 184.1005 Section 184.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DIRECT FOOD....1005 Acetic acid. (a) Acetic acid (C2H4O2, CAS Reg. No. 64-19-7) is known as ethanoic acid. It...

  1. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  2. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  3. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  4. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  5. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  6. Photochemistry of 2-nitrobenzylidene acetals.

    PubMed

    Sebej, Peter; Solomek, Tomás; Hroudná, L'ubica; Brancová, Pavla; Klán, Petr

    2009-11-20

    Photolysis of dihydroxy compounds (diols) protected as 2-nitrobenzylidene acetals (ONBA) and subsequent acid- or base-catalyzed hydrolysis of the 2-nitrosobenzoic acid ester intermediates result in an efficient and high-yielding release of the substrates. We investigated the scope and limitations of ONBA photochemistry and expanded upon earlier described two-step procedures to show that the protected diols of many structural varieties can also be liberated in a one-pot procedure. In view of the fact that the acetals of nonsymmetrically substituted diols are converted into one of the corresponding 2-nitrosobenzoic acid ester isomers with moderate to high regioselectivity, the mechanism of their formation was studied using various experimental techniques. The experimental data were found to be in agreement with DFT-based quantum chemical calculations that showed the preferential cleavage occurs on the acetal C-O bond in the vicinity of more electron-withdrawing (or less electron-donating) groups. The study also revealed considerable complexity in the cleavage mechanism and that the structural variations in the substrate can significantly alter the reaction pathway. This deprotection strategy was found to be also applicable for 2-thioethanol when released from the corresponding monothioacetal in the presence of a reducing agent, such as ascorbic acid.

  7. Rapid detergent removal from peptide samples with ethyl acetate for mass spectrometry analysis.

    PubMed

    Yeung, Yee-Guide; Stanley, E Richard

    2010-02-01

    Detergents are required for the extraction of hydrophobic proteins and for the maintenance of their solubility in solution. However, the presence of detergents in the peptide samples severely suppresses ionization in mass spectrometry (MS) analysis and decreases chromatographic resolution in LC-MS. Thus, detergents must be removed for sensitive detection of peptides by MS. This unit describes a rapid protocol in which ethyl acetate extraction is used to remove octylglucoside from protease digests without loss of peptides. This procedure can also be used to reduce interference by sodium dodecyl sulfate, Nonidet P-40, or Triton X-100 in peptide samples for MS analysis.

  8. HPLC SEPARATION OF CHIRAL ORGANOPHOSPHORUS PESTICIDES ON POLYSACCHARIDE CHIRAL STATIONARY PHASES

    EPA Science Inventory

    High-performance liquid chromatographic separation of the individual enantiomers of 12 organophosphorus pesticides (OPs) were obtained on polysaccharide chiral HPLC columns using an alkane-alcohol mobile phase. The OP pesticides were crotoxyphos, dialifor, dyfonate, fenamiphos, ...

  9. Continuous separation of carbohydrates by ion-exchange chromatography

    SciTech Connect

    Wolfgang, J.; Prior, A.; Bart, H.J.; Messenboeck, R.C.; Byers, C.H.

    1997-01-01

    A synthetic mixture of fructose, mannitol and sorbitol was continuously separated by a chromatographic method using a cation-exchange resin (Dowex 50W-X8) in its Ca{sup 2+}-form as the stationary phase. An annular chromatograph (AC) was used to achieve a continuous mode of operation. Distribution and mass transfer coefficients of the three substances as well as bed properties were obtained by batch chromatography. The separation was simulated mathematically in terms of an approximate linear chromatographic theory was applied to the modeling of the behavior of the continuous separations. The influence of rotation rate, column loading, eluent flow rate and feed concentration on the resolution of the individual peaks were investigated.

  10. A compact automated radionuclide separation system for nuclear medical applications

    NASA Astrophysics Data System (ADS)

    Bond, A. H.; Horwitz, E. P.; Hines, J. J.; Young, J. E.

    2003-01-01

    The purification of radionuclides for medical applications presents unique challenges; most notably the needs for chemical purity, radionuclidic purity, and reliable production. To address these considerations, a new generator technology and instrument have been developed to permit the rapid chromatographic purification of clinically useful quantities of radionuclides for use in diagnostic or therapeutic nuclear medicine. The device comprises a separations module containing miniature chromatographic columns, a computer controller with driver software, and the fluid delivery components. This instrument is well suited for use in radionuclide generators as separations can typically be performed in <5 min with overall decontamination factors of >106. Chromatographic experiments targeting application in a 212Bi generator have demonstrated the usefulness of the Automated Radionuclide Separator as a low-pressure chromatography system.

  11. Liquid chromatographic determination and identification tests for dexamethasone in bulk drugs and elixirs: collaborative study.

    PubMed

    Bunch, E A

    1987-01-01

    A normal phase liquid chromatographic method for the determination of dexamethasone in bulk drugs and elixirs was collaboratively studied by 6 laboratories. The method uses a silica column, water-modified acetic acid-methanol-methylene chloride mobile phase, cortisone internal standard, and photometric detection at 254 nm. Collaborators were supplied blind duplicate samples of 3 bulk drugs, 2 commercial elixirs, and 1 authentic elixir. Dexamethasone elixir dosage level is 0.5 mg/5 mL. Mean recovery of dexamethasone from the authentic elixir formulated to contain 0.471 mg/5 mL was 94.5%. (Authentic elixirs were found to stabilize about 6% below the theoretical concentration.) Mean recovery for the bulk drugs was between 97.1 and 100.1%. Mean coefficients of variation for bulk drug and elixir samples were less than 0.8% and 3.6%, respectively. Identification tests for dexamethasone by thin-layer chromatography, infrared spectroscopy, and relative LC retention times, as well as the gas chromatographic determination of alcohol in the elixirs were also collaboratively studied. Mean recovery of alcohol from the synthetic elixir was 98.6%. The mean coefficient of variation for alcohol for all samples analyzed was less than 1.4%. The LC method for dexamethasone in drug substance and elixirs, the identification tests, and the GC method for alcohol in dexamethasone elixirs have been adopted official first action.

  12. Detection system for a gas chromatograph

    DOEpatents

    Hayes, John M.; Small, Gerald J.

    1984-01-01

    A method and apparatus are described for the quantitative analysis of vaporizable compounds, and in particular of polycyclic aromatic hydrocarbons which may be induced to fluoresce. The sample to be analyzed is injected into a gas chromatography column and is eluted through a narrow orifice into a vacuum chamber. The free expansion of the eluted sample into the vacuum chamber creates a supersonic molecular beam in which the sample molecules are cooled to the extent that the excited vibrational and rotational levels are substantially depopulated. The cooled molecules, when induced to fluoresce by laser excitation, give greatly simplified spectra suitable for analytical purposes. The laser induced fluorimetry provides great selectivity, and the gas chromatograph provides quantitative transfer of the sample to the molecular beam.

  13. Gas Chromatographic Detectors for Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Humphry, Donald E.; Takeuchi, Nori; Chang, Sherwood (Technical Monitor)

    1997-01-01

    Exobiology flight experiments require highly sensitive instrumentation for in situ chemical analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. Future missions to Mars', comets, or planetary moons such as Europa, will perform experiments with complex analyses. In addition, instrumentation for such missions must perform under severely restricted conditions with limited resources. To meet these analytical requirements, improved methods and highly sensitive yet smaller instruments must continually be developed with increasingly greater capabilities. We describe here efforts to achieve this objective, for past and future missions, through the development of new or the improvement of existing sensitive, miniaturized gas chromatographic detectors.

  14. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1989-09-19

    A moving belt interface is described for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer. 8 figs.

  15. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1989-01-01

    A moving belt interface for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer.

  16. Recent developments in the chromatographic bioanalysis of approved kinase inhibitor drugs in oncology.

    PubMed

    Rood, Johannes J M; Schellens, Jan H M; Beijnen, Jos H; Sparidans, Rolf W

    2016-10-25

    In recent years (2010-present) there has been an increase in the number of publications reporting the development, validation and use of bioanalytical methods in the rapidly expanding drug class of small molecule protein kinase inhibitors. Most reports describe the technological set-up of the methods that have allowed for drug concentration measurements from various sample types. This includes plasma, dried blood-spot, and tissue-analysis. Also method development, exploration of various techniques, as well as measurement and identification of metabolites were addressed. For the bioanalysis, a variety of sample-pretreatment methods like protein-precipitation, liquid-liquid extraction, and solid-phase extraction have been employed, all varying in complexity, cleanliness and time-consumption. Chromatographic separation, nowadays, is more focused on separating components from ion-suppressive effects, since for MS/MS detection, various components do not have to be baseline separated. For detection multiple types of detectors were used, ranging from state-of-the-art high resolution, and tandem mass spectrometry with low picogram per milliliter detection limits to the classical UV-detector with several nanograms per milliliter limits. As new bioanalytical methods have arisen that do rely on chromatographic separation, for example for high-throughput analysis, these are addressed in this review as well.

  17. FTIR gas chromatographic analysis of perfumes

    NASA Astrophysics Data System (ADS)

    Diederich, H.; Stout, Phillip J.; Hill, Stephen L.; Krishnan, K.

    1992-03-01

    Perfumes, natural or synthetic, are complex mixtures consisting of numerous components. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) techniques have been extensively utilized for the analysis of perfumes and essential oils. A limited number of perfume samples have also been analyzed by FT-IR gas chromatographic (GC-FTIR) techniques. Most of the latter studies have been performed using the conventional light pipe (LP) based GC-FTIR systems. In recent years, cold-trapping (in a matrix or neat) GC-FTIR systems have become available. The cold-trapping systems are capable of sub-nanogram sensitivities. In this paper, comparison data between the LP and the neat cold-trapping GC- FTIR systems is presented. The neat cold-trapping interface is known as Tracer. The results of GC-FTIR analysis of some commercial perfumes is also presented. For comparison of LP and Tracer GC-FTIR systems, a reference (synthetic) mixture containing 16 major and numerous minor constituents was used. The components of the mixture are the compounds commonly encountered in commercial perfumes. The GC-FTIR spectra of the reference mixture was obtained under identical chromatographic conditions from an LP and a Tracer system. A comparison of the two sets of data thus generated do indeed show the enhanced sensitivity level of the Tracer system. The comparison also shows that some of the major components detected by the Tracer system were absent from the LP data. Closer examination reveals that these compounds undergo thermal decomposition on contact with the hot gold surface that is part of the LP system. GC-FTIR data were obtained for three commercial perfume samples. The major components of these samples could easily be identified by spectra search against a digitized spectral library created using the Tracer data from the reference mixture.

  18. Characterisation of wax works of art by gas chromatographic procedures.

    PubMed

    Regert, M; Langlois, J; Colinart, S

    2005-10-14

    To identify the various natural and synthetic substances used by sculptors at the end of the 19th century, several contemporary reference samples were investigated by high temperature gas chromatography (HT GC) and HT GC-MS. Using specific chromatographic conditions and minimising sample preparation, we could separate, detect and identify a wide range of biomolecular markers covering a great variety of molecular weights and volatilities, with a minimum amount of sample, in a single run. Beeswax, spermaceti, carnauba, candellila and Japan waxes as well as pine resin derivatives, animal fats, paraffin, ozokerite and stearin, used as additives in wax works of art, were chemically investigated. In the case of low volatile compounds, transbutylation was performed. The structure of long-chain esters of spermaceti was elucidated for the first time by HT GC-MS analysis. Such a method was then carried out on 10 samples collected on a statuette of Junon by Antoine-Louis Barye (Louvre Museum, Paris, France) and on a sculpture by Aimé-Jules Dalou (Musée de la Révolution Française, Vizille, France). The analytical results obtained provide new data on the complex recipes elaborated by sculptors at the end of the 19th century.

  19. Comprehensive two-dimensional liquid chromatographic analysis of anthocyanins.

    PubMed

    Willemse, Chandré M; Stander, Maria A; Tredoux, Andreas G J; de Villiers, André

    2014-09-12

    Anthocyanins are naturally occurring plant pigments whose accurate analysis is hampered by their complexity and unique chromatographic behaviour associated with on-column conversion reactions. This paper reports the evaluation of off-line comprehensive two-dimensional liquid chromatography (LC×LC) for the analysis of anthocyanins. Hydrophilic interaction chromatography (HILIC) was used in the first dimension in combination with reversed phase liquid chromatography (RP-LC) in the second dimension. For the selective detection of anthocyanins, diode array detection was used, while high resolution quadrupole-time-of-flight mass spectrometry (Q-TOF) was used for compound identification. As application, the HILIC×RP-LC separation of diverse anthocyanins in blueberries, red radish, black beans, red grape skins and red cabbage is demonstrated. Off-line HILIC×RP-LC revealed information which could not be obtained by one-dimensional HPLC methods, while the structured elution order for the anthocyanins simplifies compound identification and facilitates the comparison of anthocyanin content of natural products by means of contour plots.

  20. Enhancement of fluorescence detection in chromatographic methods by computer analysis of second order data. Progress report, August 1, 1990--October 1, 1993

    SciTech Connect

    Rutan, S.C.

    1993-12-31

    Two types of experiments were studied during the course of this project. The first was liquid chromatographic separation of polyaromatic hydrocarbons (PAHs) followed by detection with full-spectrum fluorescence spectroscopy using anintensified diode array detector. Methods such as generalized rank annihilation and adaptive Kalman filtering were developed and evaluated. The second was the use of a thin-layer chromatographic or planar electrophoretic separation of analytes (amino acids or enzymes). The analytes are then reacted with a reagent or enzyme substrate; the reaction is followed by fluorescence intensity vs time and migration distance, and kinetic analysis is used to quantify the component species.