Sample records for acetate chromatographic separation

  1. Development of liquid chromatographic enantiomer separation methods and validation for the estimation of (R)-enantiomer in eslicarbazepine acetate.

    PubMed

    Mone, Mahesh Kumar; Chandrasekhar, K B

    2011-01-01

    Chiral separation method development was carried out for eslicarbazepine acetate and its (R)-enantiomer on diverse chiral stationary phases. Better chiral selectivity was observed on cellulose tris-(3,5-dichlorophenylcarbamate) immobilized column (Chiralpak IC-3). Under polar organic mode (POM), with 100% acetonitrile as mobile phase and 0.5 ml/min flow, a resolution close to three was achieved. With normal phase (NP) mobile phase consisting dichloromethane:ethanol (90:10, v/v) and 1.0 ml/min flow, a resolution close to six was achieved. Detection was done by UV at 220 and 240 nm respectively. Both the methods were found to be robust and were validated with respect to robustness, precision, linearity, limit of detection, limit of quantification and accuracy. The proposed methods are suitable for the accurate estimation of (R)-enantiomer in bulk drug samples up to 0.1% when a 1mg/ml analyte test solution is chromatographed. PMID:20832962

  2. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, F.T.

    Intermetallic compounds with the CaCu/sub 5/ type of crystal structure, particularly LaNiCo/sub 4/ and CaNi/sub 5/, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen cn produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  3. Chromatographic hydrogen isotope separation

    DOEpatents

    Aldridge, Frederick T.

    1981-01-01

    Intermetallic compounds with the CaCu.sub.5 type of crystal structure, particularly LaNiCo.sub.4 and CaNi.sub.5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors.

  4. Estimating optimal time for fast chromatographic separations.

    PubMed

    Welch, Christopher J; Regalado, Erik L

    2014-09-01

    The term t(min cc) provides a ready estimate of the shortest time that can be obtained by "column cutting" for baseline resolution of two components showing excess chromatographic resolution. While actual column cutting is impractical, the t(min cc) value is shown to be closely related to the minimum separation time obtainable by adjusting other parameters such as flow rate, mobile phase composition, and temperature, affording scientists interested in the development of fast chromatographic separations a convenient tool for estimating the minimum separation time that can be obtained by modifying a given method development screening result. Furthermore, the relationship between t(min cc) and the minimum separation time obtainable by adjusting other parameters is shown to be dependent on the speed of the screening method, with aggressive screening gradients affording t(min cc) estimates that match the actual minimum separation time, and "lazy" screening gradients affording t(min cc) values that overestimate minimum separation time. Consequently, the analysis of the relationship between t(min cc) and actual minimum separation time may be a useful tool for determining the "fitness" of method development screening methods. PMID:24995384

  5. Chromatographic Separations of Enantiomers and Underivatized Oligosaccharides

    SciTech Connect

    Ying Liu

    2004-12-19

    My graduate research has focused on separation science and bioanalytical analysis, which emphasized in method development. It includes three major areas: enantiomeric separations using high performance liquid chromatography (HPLC), Super/subcritical fluid chromatography (SFC), and capillary electrophoresis (CE); drug-protein binding behavior studies using CE; and carbohydrate analysis using liquid chromatograph-electrospray ionization mass spectrometry (LC-ESI-MS). Enantiomeric separations continue to be extremely important in the pharmaceutical industry. An in-depth evaluation of the enantiomeric separation capabilities of macrocyclic glycopeptides CSPs with SFC mobile phases was investigated using a set of over 100 chiral compounds. It was found that the macrocyclic based CSPs were able to separate enantiomers of various compounds with different polarities and functionalities. Seventy percent of all separations were achieved in less than 4 min due to the high flow rate (4.0 ml/min) that can be used in SFC. Drug-protein binding is an important process in determining the activity and fate of a drug once it enters the body. Two drug/protein systems have been studied using frontal analysis CE method. More sensitive fluorescence detection was introduced in this assay, which overcame the problem of low sensitivity that is common when using UV detection for drug-protein studies. In addition, the first usage of an argon ion laser with 257 nm beam coupled with CCD camera as a frontal analysis detection method enabled the simultaneous observation of drug fluorescence as well as the protein fluorescence. LC-ESI-MS was used for the separation and characterization of underivatized oligosaccharide mixtures. With the limits of detection as low as 50 picograms, all individual components of oligosaccharide mixtures (up to 11 glucose-units long) were baseline resolved on a Cyclobond I 2000 column and detected using ESI-MS. This system is characterized by high chromatographic

  6. Chromatographic separation of cholesterol in foods.

    PubMed

    Fenton, M

    1992-10-30

    Based on the current literature and on experience gained in the laboratory, a simplified procedure using direct saponification (0.4 M potassium hydroxide in ethanol and heating at 60 degrees C for 1 h) is the most appropriate method for the determination of total cholesterol in foods. Extraction of the unsaponifiable matter with hexane is efficient and no extra clean-up is required before quantification. An internal standard, 5 alpha-cholestane or epicoprostanol, should be added to the sample prior to saponification and, together with reference standards, carried through the entire procedure to ensure accurate results. A significant improvement in cholesterol methodology has been achieved by decreasing the sample size and performing all the sample preparation steps in a single tube. The method has the advantages of elimination of an initial solvent extraction for total lipids and errors resulting from multiple extractions, transfers, filtration and wash steps after saponification. The resulting hexane extract, which contains a variety of sterols and fat soluble vitamins, requires an efficient capillary column for complete resolution of cholesterol from the other compounds present. The development of fused-silica capillary columns using cross-linked and bonded liquid phases has provided high thermal stability, inertness and separation efficiency and, together with automated cold on-column gas chromatographic injection systems, has resulted in reproducible cholesterol determinations in either underivatized or derivatized form. If free cholesterol and its esters need to be determined separately, they are initially extracted with other lipids with chloroform-methanol followed by their separation by column or thin-layer chromatography and subsequently analysed by gas or liquid chromatography. Although capillary gas chromatography offers superior efficiency in separation, the inherent benefits of liquid chromatography makes it a potential alternative. Isotope dilution

  7. Optimisation of n-Hexyl Acetate Synthesis in a Chromatographic Reactor

    NASA Astrophysics Data System (ADS)

    Patel, Dipesh; Saha, Basudeb; Wakeman, Richard

    Laboratory scale batch chromatographic reactor experiments were carried for the esterification of acetic acid with n-hexanol to synthesise a value added ester, namely n-hexyl acetate in the presence of an ion exchange resin catalyst, Purolite CT-124. The effect of various parameters such as solvent flow rates in the regeneration step, amount of reactants in the reaction step and reaction step time was studied for optimisation of the reaction condition in a batch chromatographic reactor. This information would be useful for the design, operation and optimisation of n-hexyl acetate synthesis in a continuous chromatographic reactor.

  8. Simple high-performance liquid chromatographic method for the determination of medroxyprogesterone acetate in human plasma.

    PubMed

    Read, J; Mould, G; Stevenson, D

    1985-06-14

    The high-performance liquid chromatographic (HPLC) method was developed as a simple, reliable alternative to available methods for measuring plasma concentrations of medroxyprogesterone acetate (MPA). The HPLC method has been successfully automated and is suitable for the rapid, inexpensive analysis of large batches of plasma samples. The best approach involves a solvent extraction followed by HPLC separation and analysis. MPA can be efficiently extracted, at all pH values, by nonpolar solvents. The Spherisorb 5-ODS2 HPLC column provides excellent separation of MPA from endogenous steroids of similar structure and from extraneous plasma blank peaks. A batch of 30-40 samples can be prepared by HPLC analysis in 2-3 hours, with a chromatographic run time of 10 minutes/sample. Calibration curves between 5-250 ng/ml show a good correlation between peak height ratio and MPA concentration, even at low levels. Plasma concentrations of MPA in patients receiving 1 g/day were between 12.6-270 ng/ml in this study, suggesting that the sensitivity of this method, 10 ng/ml, is sufficient for monitoring therapeutic concentrations of MPA. The results show a wide individual variation in plasma concentrations following similar dosing schedules--a finding reported by other workers. PMID:3161906

  9. AUTOMATED MEASUREMENTS OF INFRARED SPECTRA OF CHROMATOGRAPHICALLY SEPARATED FRACTIONS

    EPA Science Inventory

    The rapid identification of trace organic pollutants in water presents one of the more severe problems for environmental analytical chemists today. Spectroscopic identifications of chromatographically separated fractions, preferably without trapping each sample, yields more certa...

  10. Gas chromatographic separation of hydrogen isotopes using metal hydrides

    SciTech Connect

    Aldridge, F.T.

    1984-05-09

    A study was made of the properties of metal hydrides which may be suitable for use in chromatographic separation of hydrogen isotopes. Sixty-five alloys were measured, with the best having a hydrogen-deuterium separation factor of 1.35 at 60/sup 0/C. Chromatographic columns using these alloys produced deuterium enrichments of up to 3.6 in a single pass, using natural abundance hydrogen as starting material. 25 references, 16 figures, 4 tables.

  11. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    USGS Publications Warehouse

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  12. Fast gas chromatographic separation of biodiesel.

    SciTech Connect

    Pauls, R. E.

    2011-05-01

    A high-speed gas chromatographic method has been developed to determine the FAME distribution of B100 biodiesel. The capillary column used in this work has dimensions of 20 m x 0.100 mm and is coated with a polyethylene glycol film. Analysis times are typically on the order of 4-5 min depending upon the composition of the B100. The application of this method to a variety of vegetable and animal derived B100 is demonstrated. Quantitative results obtained with this method were in close agreement with those obtained by a more conventional approach on a 100 m column. The method, coupled with solid-phase extraction, was also found suitable to determine the B100 content of biodiesel-diesel blends.

  13. Chromatographically separable rotamers of an unhindered amide

    PubMed Central

    Geffe, Mario; Andernach, Lars; Trapp, Oliver

    2014-01-01

    Summary Surprisingly stable formamide rotamers were encountered in the tetrahydroisoquinoline and morphinan series of alkaloids. We investigated the hindered rotation around the amide bond by dynamic high-performance liquid chromatography (DHPLC) and kinetic measurements of the interconversion of the rotamers which can readily be separated by HPLC as well as TLC. The experimental results of the different methods were compared to each other as well as to results obtained by DFT calculations. PMID:24778722

  14. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    ERIC Educational Resources Information Center

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  15. Separating acetic acid from furol (furfural) by electrodialysis method

    SciTech Connect

    Guan, S.F.; Li, C.S. Ye, S.T.; Shen, S.Y.; Wang, Y.T.; Yu, S.H.

    1981-01-01

    Furfural production by hydrolysis of fibrous plant materials is accompanied by formation of acetic acid in amounts depending on the material used. The amount of acetic formed in the hydrolysis of the fruit shell of oil-tea camellia (Camellia oleosa) (an oilseed-bearing tree) is equal to the amount of furfural. The acetic acid can be separated from the furfural and concentrated to 10% by electrodialysis. A smaller amount of furfural is separated with acetic acid.

  16. Rotating annular chromatograph for continuous metal separations and recovery

    SciTech Connect

    Begovich, J.M.; Sisson, W.G.

    1981-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. By continuously introducing the feed material to be separated at a stationary point at the top of the bed and eluent everywhere else around the annulus, elution chromatography occurs. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence, the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effect of annulus width and diameter has recently been studied using the same device with a 50.8-mm-wide annulus and another 0.6-m-long chromatograph with an 89-mm diameter and annulus widths of 6.4, 12.7, and 22.2 mm. These columns have been constructed of Plexiglas and typically operate at a gauge pressure of 175 kPa. To further study the effect of size and pressure, a new 445-mm-diam by 1-m-long column with a 31.8-mm-wide annulus has been fabricated. Its metal construction allows preparative-scale operation with a wide variety of liquids at pressures to 1.3 MPa. Three metal recovery systems have been explored: (1) separation of iron and aluminum in ammonium sulfate-sulfuric acid solutions; (2) separation of hafnium from zirconium in sulfuric acid solutions; and (3) the separation of copper, nickel, and cobalt in ammonium carbonate solutions. This last system simulates the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. It has been studied, using similar conditions, on each of the chromatographs, and the results demonstrate the effect of column dimensions on the quality and quantity of the separation. 8 figures, 1 table.

  17. Chromatographic separation of phenylpropanol enantiomers on a quinidine carbamate-type chiral stationary phase

    SciTech Connect

    Asnin, Leonid; Guiochon, Georges A

    2005-07-01

    The retention and the separation of the enantiomers of 1-phenylpropanol (1PP), 2-phenylpropanol (2PP), and 3-chloro-1-phenylpropanol (3CPP) on silica-bonded quinidine carbamate under normal phase HPLC conditions were investigated. A relatively high selectivity of the stationary phase for 3CPP and 1PP ({alpha} {approx} 1.07-1.09) was achieved with eluents containing ethyl acetate as the polar modifier. These mobile phases were examined in detail. Based on the set of chromatographic and thermodynamic data collected, conclusions regarding the mechanism of enantioselectivity and the structure of the selector chiral center are made.

  18. Multi-objective optimization of chromatographic rare earth element separation.

    PubMed

    Knutson, Hans-Kristian; Holmqvist, Anders; Nilsson, Bernt

    2015-10-16

    The importance of rare earth elements in modern technological industry grows, and as a result the interest for developing separation processes increases. This work is a part of developing chromatography as a rare earth element processing method. Process optimization is an important step in process development, and there are several competing objectives that need to be considered in a chromatographic separation process. Most studies are limited to evaluating the two competing objectives productivity and yield, and studies of scenarios with tri-objective optimizations are scarce. Tri-objective optimizations are much needed when evaluating the chromatographic separation of rare earth elements due to the importance of product pool concentration along with productivity and yield as process objectives. In this work, a multi-objective optimization strategy considering productivity, yield and pool concentration is proposed. This was carried out in the frame of a model based optimization study on a batch chromatography separation of the rare earth elements samarium, europium and gadolinium. The findings from the multi-objective optimization were used to provide with a general strategy for achieving desirable operation points, resulting in a productivity ranging between 0.61 and 0.75 kgEu/mcolumn(3), h(-1) and a pool concentration between 0.52 and 0.79 kgEu/m(3), while maintaining a purity above 99% and never falling below an 80% yield for the main target component europium. PMID:26375205

  19. [Chromatographic separation of plasmid DNA by anion-exchange cryogel].

    PubMed

    Guo, Yantao; Shen, Shaochuan; Yun, Junxian; Yao, Kejian

    2012-08-01

    Plasmid DNA (pDNA) is used as an important vector for gene therapy, and its wide application is restricted by the purity and yield. To obtain high-purity pDNA, a chromatographic method based on anion-exchange supermacroporous cryogel was explored. The anion-exchange cryogel was prepared by grafting diethylaminoethyl-dextran to the epoxide groups of polyacrylamide-based matrix and pUC19 plasmid was used as a target to test the method. The plasmid was transferred into Escherichia coli DH5alpha, cultivated, harvested and lysed. The obtained culture was centrifuged and the supernatant was used as the plasmid feedstock, which was loaded into the anion-exchange cryogel bed for chromatographic separation. By optimizing the pH of running buffer and the elution conditions, high-purity pDNA was obtained by elution with 0.5 mol/L sodium chloride solution at pH 6.6. Compared to the traditional methods for purification of pDNA, animal source enzymes and toxic reagents were not involved in the present separation process, ensuring the safety of both the purification operations and the obtained pDNA. PMID:23185899

  20. Gas chromatographic separation of methoxylated polychlorinated biphenyl atropisomers

    PubMed Central

    Kania-Korwel, Izabela; Vyas, Sandhya M.; Song, Yang; Lehmler, Hans-Joachim

    2008-01-01

    Several polychlorinated biphenyls (PCBs) and their hydroxylated metabolites display axial chirality. Here we describe an enantioselective, gas chromatographic separation of methylated derivatives of hydroxylated (OH-)PCB atropisomers (MeO-PCB) using a chemically bonded β-cyclodextrin column (Chirasil-Dex). The atropisomers of several MeO-PCBs could be separated on this column with resolutions ranging from 0.42–0.87 under isothermal or temperature-programmed conditions. In addition, the enantiomeric fraction of OH-PCB 136 metabolites was determined in male and female rats treated with racemic PCB 136. The methylated derivatives of two OH-PCB 136 metabolites showed an enantiomeric enrichment in liver tissue, whereas PCB 136 itself was near racemic. PMID:18760792

  1. Mathematical model for multicomponent separations on the continuous annular chromatograph

    SciTech Connect

    Bratzler, R.L.; Begovich, J.M.

    1980-12-01

    A model for multicomponent separations on ion exchange columns has been adapted for use in studying the performance of the continuous annular chromatograph. The model accurately predicts solute peak positions in the column effluent and qualitatively predicts trends in solute effluent resolution as a function of increasing bandwidth of the solute feed pulse. The major virtues of the model are its simplicity in terms of the calculations involved and the fact that it incorporates the nonlinear solute-resin binding isotherms common in many ion exchange separations. Because dispersion effects are not accounted for in the model, discrepancies exist between the shapes of the effluent peaks predicted by the model and those determined experimentally.

  2. Separation studies of As(III), Sb(III) and Bi(III) by reversed-phase paper chromatographic technique

    SciTech Connect

    Raman, B.; Shinde, V.M.

    1987-07-01

    Reversed-phase paper chromatographic separations of As(III), Sb(III) and Bi(III) have been carried out on Whatman No 1 filter paper impregnated with triphenylphosphine oxide as stationary phase and using organic complexing agents such as sodium acetate, sodium succinate and sodium malonate solutions as active mobile phases. Results for the separation of binary and ternary mixtures are reported and the method has been successfully applied to the separation and detection of these elements present in real samples and at ppm level concentration.

  3. Optimization of preparative chromatographic separation of multiple rare earth elements.

    PubMed

    Max-Hansen, Mark; Ojala, Frida; Kifle, Dejene; Borg, Niklas; Nilsson, Bernt

    2011-12-23

    This work presents a method to optimize multi-product chromatographic systems with multiple objective functions. The system studied is a neodymium, samarium, europium, gadolinium mixture separated in an ion exchange chromatography step. A homogeneous Langmuir Mobile Phase Modified model is calibrated to fit the experiments, and then used to perform the optimization task. For the optimization a multi-objective Differential Evolution algorithm was used, with weighting based on relative value of the components to find optimal operation points along the Pareto front. The objectives of the Pareto front are weighted productivity and weighted yield with purity as an equality constraint. A prioritizing scheme based on relative values is applied for determining the pooling order. A simple rule of thumb for pooling strategy selection is presented. The multi-objective optimization gives a Pareto front which shows the rule of thumb, as a gap in one of the objective functions. PMID:22079482

  4. Mass spectrometric and high-performance liquid chromatographic studies of medroxyprogesterone acetate metabolites in human plasma.

    PubMed

    Sturm, G; Häberlein, H; Bauer, T; Plaum, T; Stalker, D J

    1991-01-01

    Medroxyprogesterone acetate (MPA) treatment has been shown to exert several beneficial effects in cancer patients. It has been suggested that such effects are due in part to the metabolites derived from MPA in vivo. The first results are reported on the identification of 2 alpha-hydroxy- and 21-hydroxy-MPA, 20-dihydro-MPA, 17 alpha-acetoxy-2 alpha,3 beta-dihydroxy-6 alpha-methylpregn-1,4-dien-20-one and two X,21-dihydroxy-MPAs, one of them presumably being 6 alpha-hydroxymethyl-21-hydroxy-MPA, in patient's plasma by high-performance liquid chromatographic (HPLC), gas chromatographic-mass spectrometric and NMR methods. Additionally, the presence of other metabolites such as di- and tetrahydro-MPAs and 6,21-dihydroxy-MPA, found in urine and other samples, was demonstrated in plasma. For routine clinical examinations an HPLC method is described for determination of, e.g., the unreduced MPA metabolite group in Sep-Pak-ODS column extracts of patients' plasma. PMID:1827448

  5. Evolutionary multi-objective optimization based comparison of multi-column chromatographic separation processes for a ternary separation.

    PubMed

    Heinonen, Jari; Kukkonen, Saku; Sainio, Tuomo

    2014-09-01

    Performance characteristics of two advanced multi-column chromatographic separation processes with discontinuous feed, Multi-Column Recycling Chromatogrphy (MCRC) and Japan Organo (JO), were investigated for a ternary separation using multi-objective optimization with an evolutionary algorithm. Conventional batch process was used as a reference. Fractionation of a concentrated acid hydrolysate of wood biomass into sulfuric acid, monosaccharide, and acetic acid fractions was used as a model system. Comparison of the separation processes was based on selected performance parameters in their optimized states. Flow rates and step durations were taken as decision variables whereas the column configuration and dimensions were fixed. The MCRC process was found to be considerably more efficient than the other processes with respect to eluent consumption. The batch process gave the highest productivity and the JO process the lowest. Both of the multi-column processes gave significantly higher monosaccharide yield than the batch process. When eluent consumption and monosaccharide yield are taken into account together with productivity, the MCRC process was found to be the most efficient in the studied case. PMID:25060000

  6. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  7. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  8. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  9. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  10. 21 CFR 862.2230 - Chromatographic separation material for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... chromatographic separation material for clinical use is a device accessory (e.g., ion exchange absorbents, ion exchagne resins, and ion papers) intended for use in ion exchange chromatography, a procedure in which...

  11. Chromatographic separation and concentration of quercetin and (+)-catechin using mesoporous composites based on MCM-41

    NASA Astrophysics Data System (ADS)

    Karpov, S. I.; Belanova, N. A.; Korabel'nikova, E. O.; Nedosekina, I. V.; Roessner, F.; Selemenev, V. F.

    2015-05-01

    Data on chromatographic separation of quercetin and (+)-catechin-flavonoids with similar physicochemical (including sorption) properties—are presented. The highest efficiency of chromatographic process at high sorption capacity of the material with respect to quercetin and slightly lower capacity for (+)-catechin were observed when silylated composites of ordered MCM-41 type materials were used. The application of acetonitrile as a solvent increased the sorption capacity of the material and can be recommended for separation of related polyphenol substances and their determination using ordered MCM-41 modified with trimethylchlorosilane as a stationary phase in a chromatographic column.

  12. Improved Chromatographic Separation of Sitagliptin Phosphate and Metformin Hydrochloride

    PubMed Central

    Hendy, Moataz S.

    2015-01-01

    New UPLC method was developed for determination of sitagliptin and metformin using Symmetry C18 column (100 mm × 2.1 mm, 2.2 μm) and isocratic elution (methanol 20%), pH (3.5) as a mobile phase. The ultraviolet detector was operated at 220 nm and the column temperature was 50°C. Linearity parameters were acceptable over the concentration ranges of 2-12 μgml-1 and 5-35 μgml-1 for sitagliptin and metformin, respectively. The variables were premeditated to adjust the chromatographic conditions using design of experiment. The proposed method was proved to be accurate for the quality control of the mentioned drugs in their pharmaceutical dosage form. PMID:26759536

  13. Improved Chromatographic Separation of Sitagliptin Phosphate and Metformin Hydrochloride.

    PubMed

    Hendy, Moataz S

    2015-12-01

    New UPLC method was developed for determination of sitagliptin and metformin using Symmetry C18 column (100 mm × 2.1 mm, 2.2 μm) and isocratic elution (methanol 20%), pH (3.5) as a mobile phase. The ultraviolet detector was operated at 220 nm and the column temperature was 50°C. Linearity parameters were acceptable over the concentration ranges of 2-12 μgml(-1) and 5-35 μgml(-1) for sitagliptin and metformin, respectively. The variables were premeditated to adjust the chromatographic conditions using design of experiment. The proposed method was proved to be accurate for the quality control of the mentioned drugs in their pharmaceutical dosage form. PMID:26759536

  14. Chromatographic methods for the isolation, separation and characterisation of dissolved organic matter.

    PubMed

    Sandron, Sara; Rojas, Alfonso; Wilson, Richard; Davies, Noel W; Haddad, Paul R; Shellie, Robert A; Nesterenko, Pavel N; Kelleher, Brian P; Paull, Brett

    2015-09-01

    This review presents an overview of the separation techniques applied to the complex challenge of dissolved organic matter characterisation. The review discusses methods for isolation of dissolved organic matter from natural waters, and the range of separation techniques used to further fractionate this complex material. The review covers both liquid and gas chromatographic techniques, in their various modes, and electrophoretic based approaches. For each, the challenges that the separation and fractionation of such an immensely complex sample poses is critically reviewed. PMID:26290053

  15. Optical chromatographic sample separation of hydrodynamically focused mixtures

    PubMed Central

    Terray, A.; Hebert, C. G.; Hart, S. J.

    2014-01-01

    Optical chromatography relies on the balance between the opposing optical and fluid drag forces acting on a particle. A typical configuration involves a loosely focused laser directly counter to the flow of particle-laden fluid passing through a microfluidic device. This equilibrium depends on the intrinsic properties of the particle, including size, shape, and refractive index. As such, uniquely fine separations are possible using this technique. Here, we demonstrate how matching the diameter of a microfluidic flow channel to that of the focusing laser in concert with a unique microfluidic platform can be used as a method to fractionate closely related particles in a mixed sample. This microfluidic network allows for a monodisperse sample of both polystyrene and poly(methyl methacrylate) spheres to be injected, hydrodynamically focused, and completely separated. To test the limit of separation, a mixed polystyrene sample containing two particles varying in diameter by less than 0.5 μm was run in the system. The analysis of the resulting separation sets the framework for continued work to perform ultra-fine separations. PMID:25553179

  16. Chromatographic purification and size separation of carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Duesberg, G. S.; Muster, J.; Krstic, V.; Burghard, M.; Roth, S.

    1998-08-01

    The efficient purification of single-wall and multi-wall carbon nanotubes (NTs) by columnar size exclusion chromatography (SEC) is reported. In this process, carbon nanospheres (polyhedra), amorphous carbon and metal particles are removed from aqueous surfactant-stabilised dispersions of NT raw material. TEM and AFM investigations revealed that more than 40-50% of the purified material consists of individual tubes. In addition, length separation of the tubes is achieved.

  17. Chromatographic size separation of single-wall carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Duesberg, G. S.; Muster, J.; Krstic, V.; Burghard, M.; Roth, S.

    The efficient purification of single-wall carbon nanotubes (SWNTs) is reported. Carbon nanospheres, metal particles, and amorphous carbon could be successfully removed by size exclusion chromatography (SEC) applied to surfactant stabilised dispersions of SWNT raw material. In addition, length separation of the tubes was achieved. The SWNTs obtained can be adsorbed in high densities onto chemically modified substrates. As determined by AFM investigations, the purified material consists of about equal fractions of both individual SWNTS and ropes of SWNTs.

  18. A Microporous Metal-Organic Framework for Gas Chromatographic Separation of Alkanes

    SciTech Connect

    Chen, Banglin; Liang, Chengdu; Yang, Jun; Contreras, Damacio; Clancy, Yvette; Lobkovsky, Emil B.; Yaghi, Omar; Dai, Sheng

    2006-01-01

    A zinc-based metal-organic framework (MOF) can be transformed reversibly from an open (a) to a dense (b) configuration. The microporous solid is the first example of a MOF that is highly selective in the gas-chromatographic separation of alkanes.

  19. Thin-Layer Chromatographic Separation of Phenols: An Undergraduate Laboratory Experiment.

    ERIC Educational Resources Information Center

    Kurth, Mark J.

    1986-01-01

    Background information, procedures used, and equipment needed are provided for an experiment in which a series of readily available, inexpensive, and relatively nontoxic phenols are separated using thin-layer chromatographic techniques. The experiment permits a discussion of how relative Rf values may be rationalized by considering a molecule's…

  20. Ion chromatographic separation of inorganic ions using a combination of hydrophilic interaction chromatographic column and cation-exchange resin column.

    PubMed

    Arai, Kaori; Mori, Masanobu; Hironaga, Takahiro; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-04-01

    A combination of hydrophilic interaction chromatographic (HILIC) column and a weakly acidic cation-exchange resin (WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography (IC). Firstly, the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions. The columns used were SeQuant ZIC-HILIC (ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase (ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase (HILIC-10). When using tartaric acid as the eluent, the HILIC columns indicated strong retentions for anions, based on ion-pair interaction. Especially, HILIC-10 could strongly retain anions compared with ZIC-HILIC. The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I(-) > NO3(-) > Br(-) > Cl(-) > H2PO4(-). However, since HILIC-10 could not separate analyte cations, a WCX column (TSKgel Super IC-A/C) was connected after the HILIC column in series. The combination column system of HILIC and WCX columns could successfully separate ten ions (Na+, NH4+, K+, Mg2+, Ca2+, H2PO4(-), Cl(-), Br(-), NO3(-) and I(-)) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6. The relative standard deviations (RSDs) of analyte ions by the system were in the ranges of 0.02% - 0.05% in retention times and 0.18% - 5.3% in peak areas through three-time successive injections. The limits of detection at signal-to-noise ratio of 3 were 0.24 - 0.30 micromol/L for the cations and 0.31 - 1.2 micromol/L for the anions. This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results. PMID:22799200

  1. ToF-SIMS characterisation of diterpenoic acids after chromatographic separation

    NASA Astrophysics Data System (ADS)

    Oriňák, Andrej; Oriňáková, Renáta; Arlinghaus, Heinrich F.; Vering, Guido; Hellweg, Sebastian; Cechinel-Filho, Valdir

    2006-07-01

    Microcolumn liquid chromatography (μHPLC) coupled on-line with time of flight secondary ion mass spectrometry (ToF-SIMS) was applied for mixture of diterpenoic acids (abietic, gibberellic and kaurenoic) analysis. Chromatographic effluent, with analytes separated, was carried out directly onto different, ToF-SIMS compatible surface substrates, for further ToF-SIMS analysis. Silica gel Si 60, aluminium backplate modified Si 60, monolithic silica gel and Raman spectroscopy chromatographic thin layers were used as the deposition substrates in this experiment. By ToF-SIMS surface imaging the deposition trace picture has been obtained. Effluent deposition surface area was scanned for diterpenoic acid fragment mass values based on mass spectrometric library. Measured ToF-SIMS dataset of fragment abundance and intensities were used for preliminary fragmentation schemes construction. The lowest substrate background activity has been established for monolithic silica gel thin layer and aluminium backplate modified Si 60 thin layer. In the case of Raman spectroscopy pre-treated thin layer or conventional chromatographic thin layer Si 60, the both, high background signal intensity and impossibility to construct negative ions surface image, were observed. Diterpenoic acids studied serve the similar mass spectrum but ToF-SIMS coupled with liquid chromatographic separation brings new impact to the positive identification of analytes studied.

  2. Optimization of an improved single-column chromatographic process for the separation of enantiomers.

    PubMed

    Kazi, Monzure-Khoda; Medi, Bijan; Amanullah, Mohammad

    2012-03-30

    This work addresses optimization of an improved single-column chromatographic (ISCC) process for the separation of guaifenesin enantiomers. Conventional feed injection and fraction collection systems have been replaced with customized components facilitating simultaneous separation and online monitoring with the ultimate objective of application of an optimizing controller. Injection volume, cycle time, desorbent flow rate, feed concentration, and three cut intervals are considered as decision variables. A multi-objective optimization technique based on genetic algorithm (GA) is adopted to achieve maximum productivity and minimum desorbent requirement in the region constrained by product specifications and hardware limitations. The optimization results along with the contribution of decision variables are discussed using Pareto fronts that identify non-dominated solutions. Optimization results of a similar simulated moving bed process have also been included to facilitate comparison with a continuous chromatographic process. PMID:22364669

  3. Chromatographic separation of germanium and arsenic for the production of high purity (77)As.

    PubMed

    Gott, Matthew D; DeGraffenreid, Anthony J; Feng, Yutian; Phipps, Michael D; Wycoff, Donald E; Embree, Mary F; Cutler, Cathy S; Ketring, Alan R; Jurisson, Silvia S

    2016-04-01

    A simple column chromatographic method was developed to isolate (77)As (94±6% (EtOH/HCl); 74±11 (MeOH)) from germanium for potential use in radioimmunotherapy. The separation of arsenic from germanium was based on their relative affinities for different chromatographic materials in aqueous and organic environments. Using an organic or mixed mobile phase, germanium was selectively retained on a silica gel column as germanate, while arsenic was eluted from the column as arsenate. Subsequently, enriched (76)Ge (98±2) was recovered for reuse by elution with aqueous solution (neutral to basic). Greater than 98% radiolabeling yield of a (77)As-trithiol was observed from methanol separated [(77)As]arsenate [17]. PMID:26947162

  4. Ion-exchange chromatographic separation of anions on hydrated bismuth oxide impregnated papers

    SciTech Connect

    Dabral, S.K.; Muktawat, K.P.S.; Rawat, J.P.

    1988-04-01

    A comparative study of the chromatographic behavior of anions, iodide, sulfide, phosphate, arsenate, arsenite, vanadate, chromate, dichromate, thiosulfate, thiocyanate, ferricyanide and ferrocyanide on papers impregnated with hydrated bismuth oxide and untreated Whatman no.1 paper has been made by employing identical aqueous, non-aqueous and mixed solvent system. Sharp and compact spots were obtained with impregnated papers whereas the opposite applied to plain papers. Various analytically important binary and ternary separations are reported.

  5. Continuous countercurrent chromatographic separator for the purification of sugars from biomass hydrolyzate. Final project report, July 1, 1996--September 30, 1997

    SciTech Connect

    Wooley, R J

    1997-12-01

    Production of pure sugars is required to enable production of fuels and chemicals from biomass feedstocks. Hydrolysis of cellulose and hemicellulose (principal constituents of biomass) produces sugars that can be utilized in various fermentation process to produce valuable chemicals. Unfortunately, the hydrolysis process also liberates chemicals from the biomass that can be toxic to the fermenting organisms. The two primary toxic components of biomass hydrolyzate are sulfuric acid (catalyst used in the hydrolysis) and acetic acid (a component of the feed biomass). In the standard batch chromatographic separation of these three components, sugar elutes in the middle. Batch chromatographic separations are not practical on a commercial scale, because of excess dilution and high capital costs. Because sugar is the {open_quotes}center product,{close_quotes} a continuous separation would require two costly binary separators. However, a single, slightly larger separator, configured to produce three products, would be more economical. This FIRST project develops a cost-effective method for purifying biomass hydrolyzate into fermentable sugars using a single continuous countercurrent separator to separate this ternary mixture.

  6. Application of Sigmoidal Transformation Functions in Optimization of Micellar Liquid Chromatographic Separation of Six Quinolone Antibiotics.

    PubMed

    Hadjmohammadi, Mohammadreza; Salary, Mina

    2016-03-01

    A chemometrics approach has been used to optimize the separation of six quinolone compounds by micellar liquid chromatography (MLC). A Derringer's desirability function, a multicriteria decision-making (MCDM) method, was tested for evaluation of two different measures of chromatographic performance (resolution and analysis time). The effect of three experimental parameters on a chromatographic response function (CRF) expressed as a product of two sigmoidal desirability functions was investigated. The sigmoidal functions were used to transform the optimization criteria, resolution and analysis time into the desirability values. The factors studied were the concentration of sodium dodecyl sulfate, butanol content and pH of the mobile phase. The experiments were done according to the face-centered cube central composite design, and the calculated CRF values were fitted to a polynomial model to correlate the CRF values with the variables and their interactions. The developed regression model showed good descriptive and predictive ability (R(2) = 0.815, F = 6.919, SE = 0.038, [Formula: see text]) and used, by a grid search algorithm, to optimize the chromatographic conditions for the separation of the mixture. The efficiency of prediction of polynomial model was confirmed by performing the experiment under the optimal conditions. PMID:26590234

  7. Extraction chromatographic separation of Am(III) and Eu(III) by TPEN-immobilized gel

    SciTech Connect

    Takeshita, K.; Ogata, T.; Oaki, H.; Inaba, Y.; Mori, A.; Yaita, T.; Koyama, S.I.

    2013-07-01

    A TPEN derivative with 4 vinyl groups, N,N,N',N' -tetrakis-(4-propenyloxy-2-pyridylmethyl)ethylenediamine (TPPEN) was synthesized for the separation of trivalent minor actinides (Am(III)) and lanthanides (Eu(III)). A co-polymer gel with TPPEN and N-isopropylacrylamide (NIPA) showed a high separation factor of Am(III) over Eu(III) (SF[Am/Eu]), which was evaluated to be 26 at pH=5. Thin film of NIPA-TPPEN gel (average thickness: 2-40 nm) was immobilized on the pore surface in porous silica particles (particle diameter : 50 μm, average pore diameter : 50 and 300 nm) and a chromatographic column (diameter: 6 mm, height: 11 mm) packed with the gel-coated particles was prepared. A small amount of weakly acidic solution (pH=4) containing Am(III) and Eu(III) was supplied in the column and the elution tests of Am(III) and Eu(III) were carried out. Eu(III) was recovered separately by a weakly acidic eluent (pH=4) at 313 K and Am(III) by a highly acidic eluent (pH=2) at 298 K. These results suggest that the contentious separation of minor actinides and lanthanides is attainable by a new extraction chromatographic process with two columns adjusted to 298 K and 313 K. (authors)

  8. A trade off between separation, detection and sustainability in liquid chromatographic fingerprinting.

    PubMed

    Funari, Cristiano S; Carneiro, Renato L; Cavalheiro, Alberto J; Hilder, Emily F

    2014-08-01

    It is now recognized that analytical chemistry must also be a target for green principles, in particular chromatographic methods which typically use relatively large volumes of hazardous organic solvents. More generally, high performance liquid chromatography (HPLC) is employed routinely for quality control of complex mixtures in various industries. Acetonitrile and methanol are the most commonly used organic solvents in HPLC, but they generate an impact on the environment and can have a negative effect on the health of analysts. Ethanol offers an exciting alternative as a less toxic, biodegradable solvent for HPLC. In this work we demonstrate that replacement of acetonitrile with ethanol as the organic modifier for HPLC can be achieved without significantly compromising analytical performance. This general approach is demonstrated through the specific example analysis of a complex plant extract. A benchmark method employing acetonitrile for the analysis of Bidens pilosa extract was statistically optimized using the Green Chromatographic Fingerprinting Response (GCFR) which includes factors relating to separation performance and environmental parameters. Methods employing ethanol at 30 and 80°C were developed and compared with the reference method regarding their performance of separation (GCFR) as well as by a new metric, Comprehensive Metric to Compare Liquid Chromatography Methods (CM). The fingerprint with ethanol at 80°C was similar to or better than that with MeCN according to GCFR and CM. This demonstrates that temperature may be used to replace harmful solvents with greener ones in HPLC, including for solvents with significantly different physiochemical properties and without loss in separation performance. This work offers a general approach for the chromatographic analysis of complex samples without compromising green analytical chemistry principles. PMID:24952659

  9. LIQUID CHROMATOGRAPHIC SEPARATION OF THE ENANTIOMERS OF TRANS-CHLORDANE, CIS-CHLORDANE, HEPTACHLOR, HEPTACHLOR EPOXIDE AND ALPHA-HEXACHLOROCYCLOHEXANE WITH APPLICATION TO SMALL-SCALE PREPARATIVE SEPARATION

    EPA Science Inventory

    Analytical high-performance liquid chromatographic separations of the individual enantiomers of five polychlorinated compounds were obtained on polysaccharide stereoselective HPLC columns. The enantiomers of the pesticides trans-chlordane, cis-chlordane and heptachlor were separa...

  10. [Development of online conventional array-based two-dimensional liquid chromatographic system for proteins separation in human plasma].

    PubMed

    Huang, Zhi; Hong, Guangfeng; Gao, Mingxia; Zhang, Xiangmin

    2014-04-01

    Human plasma is one of the proteins-containing samples most difficult to characterize on account of the wide dynamic concentration range of its intact proteins. Herein, we developed a high-throughput conventional array-based two-dimensional liquid chromatographic system for proteins separation in human plasma in online mode. In the system, a conventional strong-anion exchange chromatographic column was used as the first separation dimension and eight parallel conventional reversed-phase liquid chromatographic columns were integrated as the second separation dimension. The fractions from the first dimension were sequentially transferred into the corresponding reversed-phase liquid chromatographic precolumns for retention and enrichment using a 10-port electrically actuated multi-position valve. The second dimensional solvent flow was directly and identically split into 8 channels. The fractions were concurrently back-flushed from the precolumns into the 8 conventional RP columns and were separated simultaneously. An 8-channel fraction collector was refitted to collect the reversed-phase liquid chromatographic fractions for further investigation. Bicinchoninic acid (BCA) dyein solution was conveniently used for high-abundance protein location. Two separation dimensions were relatively independent parts, as well as each channel of the second dimensional array separation. Therefore, the new system could improve the separation throughput and total peak capacity. The system was successfully applied for the separation of human plasma intact proteins. The results indicated the established system is an effective method for removing high abundance proteins in plasma and in-depth research in plasma proteomics. PMID:25069321

  11. Clickable Periodic Mesoporous Organosilica Monolith for Highly Efficient Capillary Chromatographic Separation.

    PubMed

    Wu, Ci; Liang, Yu; Yang, Kaiguang; Min, Yi; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2016-02-01

    A novel clickable periodic mesoporous organosilica monolith with the surface area up to 1707 m(2) g(-1) was in situ synthesized in the capillary by the one-step condensation of the organobridged-bonded alkoxysilane precursor bis(triethoxysilyl)ethylene. With Si-C bonds in the skeleton, the monolith possesses excellent chemical and mechanical stability. With vinyl groups highly loaded and homogeneously distributed throughout the structure, the monolith can be readily functionalized with functional groups by effective thiol-ene "click" chemistry reaction. Herein, with "click" modification of C18, the obtained monolith was successfully applied for capillary liquid chromatographic separation of small molecules and proteins. The column efficiency could reach 148,000 N/m, higher than most reported hybrid monoliths. Moreover, intact proteins could be separated well with good reproducibility, even after the monolithic column was exposed by basic mobile phase (pH 10.0) overnight, demonstrating the great promising of such monolith for capillary chromatographic separation. PMID:26751092

  12. Efficient method development strategy for challenging separation of pharmaceutical molecules using advanced chromatographic technologies.

    PubMed

    Xiao, Kang Ping; Xiong, Yuan; Liu, Fang Zhu; Rustum, Abu M

    2007-09-01

    In this paper, we describe a strategy that can be used to efficiently develop a high-performance liquid chromatography (HPLC) separation of challenging pharmaceutical molecules. This strategy involves use of advanced chromatographic technologies, such as a computer-assisted chromatographic method development tool (ChromSword) and an automated column switching system (LC Spiderling). This process significantly enhances the probability of achieving adequate separations and can be a large time saver for bench analytical scientists. In our study, the ChromSword was used for mobile phase screening and separation optimization, and the LC Spiderling was used to identify the most appropriate HPLC columns. For proof of concept, the analytes employed in this study are the structural epimers betamethylepoxide and alphamethylepoxide (also known as 16-beta methyl epoxide and 16-alpha methyl epoxide). Both of these compounds are used in the synthesis of various active pharmaceutical ingredients that are part of the steroid pharmaceutical products. While these molecules are relatively large in size and contain various polar functional groups and non-polar cyclic carbon chains, their structures differ only in the orientation of one methyl group. To our knowledge, there is no reported HPLC separation of these two molecules. A simple gradient method was quickly developed on a 5 cm YMC Hydrosphere C(18) column that separated betamethylepoxide and alphamethylepoxide in 10 min with a resolution factor of 3.0. This high resolution provided a true baseline separation even when the concentration ratio between these two epimers was 10,000:1. Although outside of the scope of this paper, stability-indicating assay and impurity profile methods for betamethylepoxide and for alphamethylepoxide have also been developed by our group based on a similar method development strategy. PMID:17628579

  13. Green Chromatographic Separation of Coumarin and Vanillins Using Subcritical Water as the Mobile Phase.

    PubMed

    Kayan, Berkant; Akay, Sema; Yang, Yu

    2016-08-01

    Pure water was used as the eluent for separation of coumarin, vanillin and ethyl vanillin at temperatures ranging from 100 to 200°C using a homemade subcritical water chromatography (SBWC) system. Chromatographic separations were performed on five commercial columns including XTerra MS C18, XBridge C18, Zorbax RRHD Eclipse Plus, Zorbax SB-Phenyl and Zorbax SB-C18 columns. The retention time of all three solutes decreased with increasing water temperature. The shortest retention time among all acceptable separations, less than 4 min, was achieved on the Zorbax SB-C18 column at 200°C. While separations on the XTerra MS C18 column resulted in fronting peaks and a degradation peak from ethyl vanillin on the Zorbax RRHD Eclipse Plus column was observed, all three other columns yielded reasonable separations under SBWC conditions. In addition to separation of the standard test mixture, separation of coumarin contained in a skincare cream sample was also carried out using SBWC. PMID:27060112

  14. Extraction chromatographic separation of promethium from high active waste solutions of Purex origin

    SciTech Connect

    Ramanujam, A.; Achuthan, P.V.; Dhami, P.S.; Gopalakrishnan, V.; Kannan, R.; Mathur, J.N.

    1995-03-01

    An extraction chromatographic procedure for the separation of {sup 147}Pm from High Active Waste solutions of Purex process has been developed. Octyl(phenyl)-N,N-diisobutylcarbamoylmethylphosphine oxide(CMPO) and 2-ethylhexyl-2-ethylhexylphosphonic acid (KSM-17), both sorbed separately on an inert support(chromosorb-102) have been sequentially employed for this purpose. In the CMPO column, the rare earths and the trivalent actinides are sorbed together with uranium, plutonium and traces of few other fission products. The elution of this column with 0.04 M HNO{sub 3} gives an eluate containing trivalent actinides and lanthanides. This solution, after adjusting the pH to 2.0, is used as feed for the second extraction chromatographic column based on KSM-17. All the trivalent metal ions are sorbed on the column leaving the trace impurities in the effluent. Fractional elution of the metal ions from this column is carried out with nitric acid of varying concentrations. At 0.09 M HNO{sub 3}, the pure beta emitting fraction of {sup 147}Pm has been obtained. 16 refs., 3 figs., 2 tabs.

  15. Dried calcium alginate/magnetite spheres: a new support for chromatographic separations and enzyme immobilization

    SciTech Connect

    Burns, M.A.; Kvesitadze, G.I.; Graves, D.J.

    1985-02-01

    Dried spheres made from an alginate solution containing magnetite particles have excellent potential as a support for enzyme immobilization and chromatographic applications. The beads were found to be much stronger than gels such as polyacrylamide and dextran, indicating that high flow rates and pressures could be used in column separations. The support withstood not only temperatures of up to 120/sup 0/C, but also most pH values and common solvents. While some solutions, such as phosphate buffers, dissolved the spheres, stabilization with Tyzor TE eliminated this problem. The physical properties of the beads include a glasslike density of 2.2 g/mL, excellent sphericity, low porosity, and a narrow size distribution. The magnetite present in the support allows the beads to be used for magnetic separations such as high gradient magnetic filtration. Their high degree of microroughness provides a large exposed surface area for enzyme and ligand binding. Mixed Actinomyces fradiae proteases and Aspergillus niger ..cap alpha..-amylase, two enzymes representative of classes which attack large substrates, were immobilized on the bead's surface with high activity and stability. A cyanuric dye which can be used in chromatographic applications (Cibacron Blue F3GA) was also readily coupled to the surface of this support with good yield.

  16. In situ sol-gel preparation of porous alumina monoliths for chromatographic separations of adenosine phosphates.

    PubMed

    Zajickova, Zuzana; Rubi, Emir; Svec, Frantisek

    2011-06-01

    A method enabling the in situ preparation of porous alumina monoliths within 100 μm i.d. fused silica capillaries has been developed. These monoliths were prepared using the sol-gel process from a mixture consisting of an inorganic aluminum salt, a porogen, an epoxide, and a solvent. We investigated the effects of varying the preparation conditions on the physical characteristics of the monoliths with respect to their potential application in chromatographic separations. The best columns were obtained from a mixture of aluminum chloride hexahydrate, N,N-dimethylformamide, water, ethanol and propylene oxide. Adenosine phosphates were then separated in the optimized column with retention increasing according to number of phosphate functionalities. PMID:21497822

  17. Novel behavior of the chromatographic separation of linear and cyclic polymers.

    PubMed

    Montenegro-Burke, J Rafael; Bennett, Jackson M; McLean, John A; Hercules, David M

    2016-01-01

    In various polymerization processes, the formation of a wide variety of chains, not only in length but also in chemical composition, broadly complicates comprehensive polymer characterization. In this communication, we compare different stationary and mobile phases for the analysis of complex polymer mixtures via size-exclusion chromatography-mass spectrometry (SEC-MS). To the best of our knowledge, we report novel chromatographic effects for the separation of linear and cyclic oligomers for polyesters (PE) and polyurethanes (PUR). A complete separation for the different structures was achieved for both polymer types with a single-solvent system (acetonitrile, ACN) and without extensive optimization. Additionally, cyclic species were found to show an inverse elution profile compared to their linear counterparts, suggesting distinct physical properties between species. PMID:26637218

  18. Development and validation of a high-performance liquid chromatographic method for the determination of cyproterone acetate in human skin.

    PubMed

    Henry de Hassonville, Sandrine; Chiap, Patrice; Liégeois, Jean-François; Evrard, Brigitte; Delattre, Luc; Crommen, Jacques; Piel, Géraldine; Hubert, Philippe

    2004-09-21

    In the framework of a preliminary study on the transdermal penetration of cyproterone acetate (CPA), a simple and rapid procedure involving an extraction step coupled to a HPLC-UV determination has been developed for the separation and quantification of CPA in the two main skin layers-epidermis and dermis-after local application. The separation of epidermis and dermis layers was carefully carried out by means of a sharp spatula after skin immersion in heated water at 65 degrees C. The two skin layers were then treated separately according to the same process: (1) sample homogenization by vibration after freezing with liquid nitrogen in a Mikro-Dismembrator; (2) CPA extraction with methanol after addition of the internal standard (betamethasone dipropionate); (3) centrifugation; (4) evaporation of a supernatant aliquot; (5) dissolution of the dry residue in methanol and addition of water; (6) centrifugation; (7) injection of a supernatant aliquot into the HPLC system. The separation was achieved on octadecylsilica stationary phase using a mobile phase consisting in a mixture of acetonitrile and water (40:60 (v/v)). The method was then validated using a new approach based on accuracy profiles over a CPA concentration range from 33 to 667 ng/ml for each skin layer. Finally, the method was successfully applied to the determination of CPA to several skin samples after topical application of different gel formulations containing CPA. PMID:15351057

  19. Liquid chromatographic method for determination of water in soils and the optimization of anion separations by capillary zone electrophoresis

    SciTech Connect

    Benz, N.

    1994-10-01

    A liquid chromatographic method for the determination of water in soil or clay samples is presented. In a separate study, the optimization of electrophoretic separation of alkylated phenolate ions was optimized by varying the pH and acetonitrile concentration of the buffer solutions.

  20. Thin-layer chromatographic (TLC) separations and bioassays of plant extracts to identify antimicrobial compounds.

    PubMed

    Kagan, Isabelle A; Flythe, Michael D

    2014-01-01

    A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungi or bacteria in broth or agar), allowing time for the microbes to grow in a humid environment, and visualizing zones with no microbial growth. The effectiveness of this screening method, known as bioautography, depends on both the quality of the chromatographic separation and the care taken with microbial culture conditions. This paper describes standard protocols for TLC and contact bioautography with a novel application to amino acid-fermenting bacteria. The extract is separated on flexible (aluminum-backed) silica TLC plates, and bands are visualized under ultraviolet (UV) light. Zones are cut out and incubated face down onto agar inoculated with the test microorganism. Inhibitory bands are visualized by staining the agar plates with tetrazolium red. The method is applied to the separation of red clover (Trifolium pratense cv. Kenland) phenolic compounds and their screening for activity against Clostridium sticklandii, a hyper ammonia-producing bacterium (HAB) that is native to the bovine rumen. The TLC methods apply to many types of plant extracts and other bacterial species (aerobic or anaerobic), as well as fungi, can be used as test organisms if culture conditions are modified to fit the growth requirements of the species. PMID:24747583

  1. Thin-layer Chromatographic (TLC) Separations and Bioassays of Plant Extracts to Identify Antimicrobial Compounds

    PubMed Central

    Kagan, Isabelle A.; Flythe, Michael D.

    2014-01-01

    A common screen for plant antimicrobial compounds consists of separating plant extracts by paper or thin-layer chromatography (PC or TLC), exposing the chromatograms to microbial suspensions (e.g. fungi or bacteria in broth or agar), allowing time for the microbes to grow in a humid environment, and visualizing zones with no microbial growth. The effectiveness of this screening method, known as bioautography, depends on both the quality of the chromatographic separation and the care taken with microbial culture conditions. This paper describes standard protocols for TLC and contact bioautography with a novel application to amino acid-fermenting bacteria. The extract is separated on flexible (aluminum-backed) silica TLC plates, and bands are visualized under ultraviolet (UV) light. Zones are cut out and incubated face down onto agar inoculated with the test microorganism. Inhibitory bands are visualized by staining the agar plates with tetrazolium red. The method is applied to the separation of red clover (Trifolium pratense cv. Kenland) phenolic compounds and their screening for activity against Clostridium sticklandii, a hyper ammonia-producing bacterium (HAB) that is native to the bovine rumen. The TLC methods apply to many types of plant extracts and other bacterial species (aerobic or anaerobic), as well as fungi, can be used as test organisms if culture conditions are modified to fit the growth requirements of the species. PMID:24747583

  2. Graphitic carbon nitride as high-resolution stationary phase for gas chromatographic separations.

    PubMed

    Zheng, Yunzhong; Qi, Meiling; Fu, Ruonong

    2016-07-01

    This work presents the first example of utilization of graphitic carbon nitride (g-C3N4) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated g-C3N4 column showed the column efficiencies of 3760 plates/m and weak polarity. Its resolving capability and retention behaviours were investigated by using the Grob test mixture, and mixtures of diverse types of analytes, and structural and positional isomers. The results showed superior separation performance of the g-C3N4 stationary phase for some critical analytes and preferential retention for aromatic analytes. Specifically, it exhibited high-resolution capability for aromatic and aliphatic isomers such as methylnaphthalenes and dimethylnaphthalenes, phenanthrene and anthracene and alkane isomers. In addition, g-C3N4 column showed excellent thermal stability up to 280°C and good repeatability with relative standard deviation (RSD) values less than 0.09% for intra-day, below 0.23% for inter-day and in the range of 1.9-8.4% for between-column, respectively. The advantageous separation performance shows the potential of g-C3N4 and related materials as stationary phase in GC and other separation technologies. PMID:27266332

  3. Chromatographic cation exchange separation of decigram quantities of californium and other transplutonium elements

    SciTech Connect

    Benker, D.E.; Chattin, F.R.; Collins, E.D.; Knauer, J.B.; Orr, P.B.; Ross, R.G.; Wiggins, J.T.

    1981-01-01

    Decigram quantities of highly radioactive transplutonium elements are routinely partitioned at TRU by chromatographic elution from cation resin using AHIB eluents. Batch runs containing up to 200 mg of /sup 252/Cf can be made in about 5 h (2 h to load the feed and 3 h for the elution), with two high-pressure ion exchange columns, a small one for the initial loading of the feed and a large one for the elution. The separations achieved in the column are preserved by routing the column effluent through an alpha detector and using the response from the detector to select appropriate product fractions. The high-pressure ion exchange process has been reliable and relatively easy to operate; therefore it will continue to be used for partitioning transplutonium elements at TRU. 3 figures, 1 table.

  4. Scaleable production and separation of fermentation-derived acetic acid. Final CRADA report.

    SciTech Connect

    Snyder, S. W.; Energy Systems

    2010-02-08

    Half of U.S. acetic acid production is used in manufacturing vinyl acetate monomer (VAM) and is economical only in very large production plants. Nearly 80% of the VAM is produced by methanol carbonylation, which requires high temperatures and exotic construction materials and is energy intensive. Fermentation-derived acetic acid production allows for small-scale production at low temperatures, significantly reducing the energy requirement of the process. The goal of the project is to develop a scaleable production and separation process for fermentation-derived acetic acid. Synthesis gas (syngas) will be fermented to acetic acid, and the fermentation broth will be continuously neutralized with ammonia. The acetic acid product will be recovered from the ammonium acid broth using vapor-based membrane separation technology. The process is summarized in Figure 1. The two technical challenges to success are selecting and developing (1) microbial strains that efficiently ferment syngas to acetic acid in high salt environments and (2) membranes that efficiently separate ammonia from the acetic acid/water mixture and are stable at high enough temperature to facilitate high thermal cracking of the ammonium acetate salt. Fermentation - Microbial strains were procured from a variety of public culture collections (Table 1). Strains were incubated and grown in the presence of the ammonium acetate product and the fastest growing cultures were selected and incubated at higher product concentrations. An example of the performance of a selected culture is shown in Figure 2. Separations - Several membranes were considered. Testing was performed on a new product line produced by Sulzer Chemtech (Germany). These are tubular ceramic membranes with weak acid functionality (see Figure 3). The following results were observed: (1) The membranes were relatively fragile in a laboratory setting; (2) Thermally stable {at} 130 C in hot organic acids; (3) Acetic acid rejection > 99%; and (4

  5. Separation of Trivalent Actinides from Lanthanides in an Acetate Buffer Solution Using Cyanex 301

    SciTech Connect

    Jack D. Law; Dean R. Peterman; Terry A. Todd; Richard D. Tillotson

    2006-05-01

    The separation of trivalent actinides from the lanthanides using the active extractant in the Cyanex 301 reagent, bis(2,4,4-trimethylpentyl)dithiophosphinic acid, was studied. Specifically, the extractant was studied for an ammonium acetate/acetic acid buffered feed that would result from a transuranic separation process utilizing an ammonium acetate strip solution. Separation factors of 241Am from 154Eu with this extractant, as a function of total acetate concentration and pH, have been measured. Additionally, the extraction behavior of stable La, Ce, Pr, Nd, Sm, and Eu was measured. Separation factors were typically very high for Am from Eu at a pH ranging from 3.8 to 5.8 and a total acetate concentration ranging from 0.2 M to 1.0 M. However, separation factors across the lanthanide series varied considerably and resulted in separation of the lighter lanthanides from the heavier lanthanides at the higher pH’s.

  6. Separative analyses of a chromatographic column packed with a core-shell adsorbent for lithium isotope separation

    SciTech Connect

    Sugiyama, T.; Sugura, K.; Enokida, Y.; Yamamoto, I.

    2015-03-15

    Lithium-6 is used as a blanket material for sufficient tritium production in DT fueled fusion reactors. A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites. A model was developed and concentration profiles and time variation in the column were numerically simulated. It became clear that core-shell type adsorbents with thin porous shell were saturated rapidly relatively to fully porous one and established a sharp edge of adsorption band. This is very important feature because lithium isotope separation requires long-distance development of adsorption band. The values of HETP (Height Equivalent of a Theoretical Plate) for core-shell adsorbent packed column were estimated by statistical moments of the step response curve. The value of HETP decreased with the thickness of the porous shell. A core-shell type adsorbent is, then, useful for lithium isotope separation. (authors)

  7. Development and validation of a reversed-phase liquid chromatographic method for analysis of estradiol valerate and medroxyprogesterone acetate in a tablet formulation.

    PubMed

    Segall, A; Hormaechea, F; Vitale, M; Perez, V; Pizzorno, M T

    1999-04-01

    A simple and accurate liquid chromatographic method was developed for estimation of estradiol valerate and medroxyprogesterone acetate in pharmaceuticals. Drugs were chromatographed on a reverse phase C18 column, using a mixture (30:70) of ammonium nitrate buffer and acetonitrile and eluants monitored at a wavelength of 280 nm. Solution concentrations were measured on a weight basis to avoid the use of an internal standard. The method was statistically validated for its linearity, accuracy, precision and selectivity. Due to its simplicity and accuracy, the authors believe that the method may be used for routine quality control analysis. It does not require any specific sample preparation except the use of a column guard before the analytical column and suitable prefilter attached to the syringe prior to injection. PMID:10698544

  8. Evaluation of two commercial capillary columns for the enantioselective gas chromatographic separation of organophosphorus pesticides.

    PubMed

    Fidalgo-Used, Natalia; Blanco-González, Elisa; Sanz-Medel, Alfredo

    2006-12-15

    The separation of the enantiomers of 13 organophosphorus pesticides (OPPs) has been investigated by gas chromatography (GC) with flame ionisation detection (FID) using two different commercially available chiral columns, Chirasil-Val (l-valine-tert-butylamide) and CP-Chirasil-Dex CB (heptakis (2,3,6-tri-O-metil)-beta-cyclodextrin). Using the Chirasil-Val column no chiral resolution was obtained for the OPPs investigated under any tested experimental condition. The use of the CP-Chirasil-Dex CB stationary phase enabled good individual enantiomeric separation of two OPPs, ruelene and trichlorfon and partial separation of naled, chloretoxyphos, isophenphos and metamidophos. Also, the obtained chromatographic results showed that Chirasil-Dex could resolve enantiomers through the combination of different mechanism (e.g. formation of inclusion complexes and/or interactions outside the cyclodextrin cavity). Under optimised conditions, precision, linearity range and detection limits were evaluated for the enantiomers of ruelene and trichlorfon using CP-Chirasil-Dex CB column and electron capture detection (ECD). By using the GC-ECD method the enantiomers of these OPPs could be satisfactorily detected at very low concentration levels. The detection limits observed were 1.5ngmL(-1) and 11.5ngmL(-1) for the enantiomers of trichlorfon and ruelene, respectively. PMID:18970881

  9. Inlet backflushing device for the improvement of comprehensive two dimensional gas chromatographic separations.

    PubMed

    Edwards, Matthew; Górecki, Tadeusz

    2015-07-10

    Comprehensive two-dimensional gas chromatography (GC×GC) is recognised as a powerful tool for the separation of complex mixtures of volatile and semi-volatile compounds. In the analysis of challenging samples containing highly concentrated, active analytes or those with complicated matrices, it is often the case that less than ideal chromatography is produced. GC×GC chromatograms of such samples typically contain broad, tailing analyte bands. This results in difficulties with quantitation and poor utilisation of the separation space. In this study we investigated the inlet and the modulator as the potential sources of these tailing bands. A simple inlet backflushing device was developed to isolate the inlet from the primary column after the injection, and a similar setup was used to isolate the modulator from the primary column. The device allowed us to divert carrier gas flow back through the inlet at a specified time after the injection, while allowing analytes to pass through the column for separation. Analytes retained within the inlet were prevented from entering the column, and were subsequently removed via the carrier gas split line. The study revealed that the inlet plays a significant role in the development of tailing chromatographic bands, while the modulator simply modulates the already elongated band. Inlet backflushing is a cheap, simple and effective tool that can be used to improve the chromatography of problematic GC×GC analyses of samples consisting of concentrated and active analytes, those derived from natural products and containing complicated matrices. PMID:26028511

  10. Development and validation of a reversed-phase liquid chromatographic method for separation and simultaneous determination of COX-2 inhibitors in pharmaceuticals and its application to biological fluids.

    PubMed

    Rao, R Nageswara; Meena, S; Nagaraju, D; Rao, A Raghu Ram

    2005-06-01

    An isocratic reversed-phase high-performance liquid chromatographic method has been developed for separation and simultaneous determination of COX-2 inhibitors, viz., celecoxib, rofecoxib, valdecoxib, nimesulide and nabumetone, using 4-chloro-2-nitroaniline as internal standard. Good chromatographic separation was achieved using a reversed-phase Inertsil C(18) column with mobile phase consisting of methanol and 0.05% aqueous glacial acetic acid (68:32 v/v) using photodiode array (PDA) detector at 230 nm. It was validated with respect to accuracy, precision, linearity, limit of detection and quantification. The linearity range was found to be 1.0--20 microg/mL and the percentage recoveries were between 97.55 and 100.14. The method is suitable not only for the estimation of active ingredients in pharmaceutical dosage forms but also in vitro estimations in human plasma. It is simple, rapid, selective and capable of detecting and determining COX-2 inhibitors with a detection limit of 0.127--1.040 microg/mL simultaneously. PMID:15627281

  11. Detection and quantification of some plant growth regulators in a seaweed-based foliar spray employing a mass spectrometric technique sans chromatographic separation.

    PubMed

    Prasad, Kamalesh; Das, Arun Kumar; Oza, Mihir Deepak; Brahmbhatt, Harshad; Siddhanta, Arup Kumar; Meena, Ramavatar; Eswaran, Karuppanan; Rajyaguru, Mahesh Rameshchandra; Ghosh, Pushpito Kumar

    2010-04-28

    The sap expelled from the fresh harvest of Kappaphycus alvarezii , a red seaweed growing in tropical waters, has been reported to be a potent foliar spray. Tandem mass spectrometry of various organic extracts of the sap confirmed the presence of the plant growth regulators (PGRs) indole 3-acetic acid, gibberellin GA(3), kinetin, and zeatin. These PGRs were quantified in fresh state and after 1 year of storage by ESI-MS without recourse to chromatographic separation. Quantification was validated against HPLC data. The results may be useful in correlating with the efficacy of the sap. The methodology was extended to two other seaweeds. The method developed is convenient and precise and may find application in other agricultural formulations containing these growth hormones. PMID:20355716

  12. A novel and effective chromatographic approach to the separation of isoflavone derivatives from Pueraria lobata.

    PubMed

    Fu, Jiang; Jing, Wenguang; Wang, Weihao; Chen, Sha; Zhang, Jun; Liu, An

    2015-01-01

    A novel and effective chromatographic approach to the separation and purification of isoflavone compounds from Pueraria lobata is described. The method is based on flash chromatography (FC), coupled to preparative high performance liquid chromatography (prep-HPLC) via a six-way valve. The FC step comprised tandem reversed phase columns, pre-packed with MCI gel (Mitsubishi Chemical Corp., Tokyo, Japan) and C18 (Fuji Silysia Chemical Ltd, Osaka, Japan) resin, respectively, and was designed to separate a crude Pueraria lobata extract into several preliminary fractions. Fractions containing the target compounds were then directly injected via the six-way valve into prep-HPLC columns, without further treatment, for final isolation and purification. Nine isoflavonoids were successfully isolated, three through an online mode and the other six through an offline mode. The purities of all compounds exceeded 95.0%, as determined by HPLC with an UV-vis photodiode array detector. The convenience, low solvent consumption, and time-saving advantages of this method offer an attractive and promising approach to the isolation of natural products. PMID:25751785

  13. Computer assisted optimization of liquid chromatographic separations of small molecules using mixed-mode stationary phases.

    PubMed

    Ordoñez, Edgar Y; Benito Quintana, José; Rodil, Rosario; Cela, Rafael

    2012-05-18

    Mixed-mode stationary phases are gaining adepts in liquid chromatography (LC) as more and more applications are published and new commercial columns appear in the market ought to their ability to retain and separate analytes with multiple functionalities. The increased number of adjustable variables gives these columns an enhanced value for the chromatographer, but, on the other hand, it complicates the process of developing satisfactory separations when complex samples must be analyzed. Thus, the availability of computer assisted methods development (CAMD) tools is highly desirable in this field. Therefore, the first specific tool for the CAMD of LC separations in mixed-mode columns is presented. The tool consists in two processes. The first one develops a retention model for peaks in a predefined experimental domain of pH and buffer concentration. In this domain, the retention as a function of the proportion of organic modifier is modeled using a two-stage re-calibration process departing from isocratic retention data and then, from gradient elutions. With this two-stage approach, reliability is gained. In the second process, the model is finally interpolated and used for the unattended optimization of the different possible elution modes available in these columns. This optimization process is driven by an evolutionary algorithm. The development and application of this new chemometrics tool is demonstrated by the optimization of a mixture of neutral and ionizable compounds. Hence, several different types of gradients were generated, showing a good agreement between simulated and experimental data, with retention time errors lower than 5% in most cases. On the other hand, classical CAMD tools, such as design of experiments, were unable to efficiently deal with mixed-mode optimizations, rendering errors above 30% for several compounds. PMID:22494641

  14. Ion Exchange and Thin Layer Chromatographic Separation and Identification of Amino Acids in a Mixture: An Experiment for General Chemistry and Biotechnology Laboratories

    ERIC Educational Resources Information Center

    Brunauer, Linda S.; Caslavka, Katelyn E.; Van Groningen, Karinne

    2014-01-01

    A multiday laboratory exercise is described that is suitable for first-year undergraduate chemistry, biochemistry, or biotechnology students. Students gain experience in performing chromatographic separations of biomolecules, in both a column and thin layer chromatography (TLC) format. Students chromatographically separate amino acids (AA) in an…

  15. Liquid-chromatographic separation and on-line bioluminescence detection of creatine kinase isoenzymes

    SciTech Connect

    Bostick, W.D.; Denton, M.S.; Dinsmore, S.R.

    1980-01-01

    Isoenzymes of creatine kinase were separated by anion-exchange chromatography, with use of an elution gradient containing lithium acetate (0.1 to 0.6 mol/L). A stream splitter was used to divert a 5% side stream of column effluent, which was subsequently mixed with the reagents necessary for bioluminescence assay of the separated isoenzymes. The use of the stream splitter greatly decreased the rate of consumption of reagent and, when combined with a peristaltic pumping system, permitted independent control of the side-stream flow rate. Thus both the residence interval in a delay coil in which the ATP reaction product is formed and the bioluminescence emission was monitored in a flow-through fluorometer without use of an external light source or filters. Separation and detection of the isoenzymes of creatine kinase were rapid, sensitive, and highly selective. The incremental decrease of bioluminescence response owing to inhibition by the ions in the eluent was less than 31% across the entire gradient.

  16. Mechanism and kinetics of protein transport in chromatographic media studied by confocal laser scanning microscopy. Part II. Impact on chromatographic separations.

    PubMed

    Hubbuch, Jürgen; Linden, Thomas; Knieps, Esther; Thömmes, Jörg; Kula, Maria-Regina

    2003-12-22

    The impact of different transport mechanism on chromatographic performance was studied by confocal laser scanning microscopy (CLSM) for solutions containing bovine serum albumin (BSA) and monoclonal IgG 2a under different solid- and fluid-phase conditions. During this investigation, a clear influence of the uptake mechanism on the affinity of the respective proteins for the different adsorbents and thus separation performance of the chromatographic process could be observed. For the system SP Sepharose Fast Flow at pH 4.5 pore diffusion could be ascribed to be the dominant transport mechanism for both proteins and the adsorption profiles resembled a pattern similar to that described by the 'shrinking core' model. Under these conditions a significantly higher affinity towards the adsorbent was found for BSA when compared to IgG 2a. With changing fluid- and solid-phase conditions, however, a change of the transport mode for IgG 2a could be detected. While the exact mechanism is still unresolved it could be concluded that both occurrence and magnitude of the now governing transport mechanism depended on protein properties and interaction with the adsorbent surface. For the system SP Sepharose XL at pH 5.0 both parameters leading to the change in IgG 2a uptake were combined resulting in a clear change of the system affinity towards the IgG 2a molecule, while BSA adsorption was restricted to the most outer shell of the sorbent. PMID:14735979

  17. HPLC method development for the online-coupling of chromatographic Perilla frutescens extract separation with xanthine oxidase enzymatic assay.

    PubMed

    Kaufmann, Christine M; Grassmann, Johanna; Letzel, Thomas

    2016-05-30

    Enzyme-regulatory effects of compounds contained in complex mixtures can be unveiled by coupling a continuous-flow enzyme assay to a chromatographic separation. A temperature-elevated separation was developed and the performance was tested using Perilla frutescens plant extracts of various polarity (water, methanol, ethanol/water). Owning to the need of maintaining sufficient enzymatic activity, only low organic solvent concentrations can be added to the mobile phase. Hence, to broaden the spectrum of eluting compounds, two different organic solvents and various contents were tested. The chromatographic performance and elution was further improved by the application of a moderate temperature gradient to the column. By taking the effect of eluent composition as well as calculated logD values and molecular structure of known extract compounds into account, unknown features were tentatively assigned. The method used allowed the successful observation of an enzymatic inhibition caused by P. frutescens extract. PMID:26986639

  18. Metal-organic frameworks for analytical chemistry: from sample collection to chromatographic separation.

    PubMed

    Gu, Zhi-Yuan; Yang, Cheng-Xiong; Chang, Na; Yan, Xiu-Ping

    2012-05-15

    In modern analytical chemistry researchers pursue novel materials to meet analytical challenges such as improvements in sensitivity, selectivity, and detection limit. Metal-organic frameworks (MOFs) are an emerging class of microporous materials, and their unusual properties such as high surface area, good thermal stability, uniform structured nanoscale cavities, and the availability of in-pore functionality and outer-surface modification are attractive for diverse analytical applications. This Account summarizes our research on the analytical applications of MOFs ranging from sampling to chromatographic separation. MOFs have been either directly used or engineered to meet the demands of various analytical applications. Bulk MOFs with microsized crystals are convenient sorbents for direct application to in-field sampling and solid-phase extraction. Quartz tubes packed with MOF-5 have shown excellent stability, adsorption efficiency, and reproducibility for in-field sampling and trapping of atmospheric formaldehyde. The 2D copper(II) isonicotinate packed microcolumn has demonstrated large enhancement factors and good shape- and size-selectivity when applied to on-line solid-phase extraction of polycyclic aromatic hydrocarbons in water samples. We have explored the molecular sieving effect of MOFs for the efficient enrichment of peptides with simultaneous exclusion of proteins from biological fluids. These results show promise for the future of MOFs in peptidomics research. Moreover, nanosized MOFs and engineered thin films of MOFs are promising materials as novel coatings for solid-phase microextraction. We have developed an in situ hydrothermal growth approach to fabricate thin films of MOF-199 on etched stainless steel wire for solid-phase microextraction of volatile benzene homologues with large enhancement factors and wide linearity. Their high thermal stability and easy-to-engineer nanocrystals make MOFs attractive as new stationary phases to fabricate MOF

  19. A theoretical model for the separation of glucose and fructose mixtures by using a semicontinuous chromatographic refiner

    SciTech Connect

    Lee, Kwang Nam; Lee, Won Kook )

    1992-03-01

    The separation of a glucose and fructose mixture was experimentally performed by using a semicontinuous chromatographic refiner (SCCR) packed with Ca{sup 2+} ion in the form of DOWEX 50W 12X resin. The plug flow model with velocity-dependent mass transfer resistance was resistance was presented for calculating both products and on-concentrations in the SCCR unit, and the validity of the model was experimentally confirmed.

  20. Improvement in HPLC separation of acetic acid and levulinic acid in the profiling of biomass hydrolysate.

    PubMed

    Xie, Rui; Tu, Maobing; Wu, Yonnie; Adhikari, Sushil

    2011-04-01

    5-Hydroxymethylfurfural (HMF) and furfural could be separated by the Aminex HPX-87H column chromatography, however, the separation and quantification of acetic acid and levulinic acid in biomass hydrolysate have been difficult with this method. In present study, the HPLC separation of acetic acid and levulinic acid on Aminex HPX-87H column has been investigated by varying column temperature, flow rate, and sulfuric acid content in the mobile phase. The column temperature was found critical in resolving acetic acid and levulinic acid. The resolution for two acids increased dramatically from 0.42 to 1.86 when the column temperature was lowered from 60 to 30 °C. So did the capacity factors for levulinic acid that was increased from 1.20 to 1.44 as the column temperature dropped. The optimum column temperature for the separation was found at 45 °C. Variation in flow rate and sulfuric acid concentration improved not as much as the column temperature did. PMID:21316945

  1. High performance liquid chromatographic separation of polycyclic aromatic hydrocarbons on microparticulate pyrrolidone and application to the analysis of shale oil

    SciTech Connect

    Mourey, T.H.; Siggia, S.; Uden, P.C.; Crowley, R.J.

    1980-05-01

    A chemically bonded pyrrolidone substrate is used for the high performance liquid chromatographic separation of polycyclic aromatic hydrocarbons. The cyclic amide phase interacts electronically with the polycyclic aromatic hydrocarbons in both the normal and reversed phase modes. Separation is effected according to the number of aromatic rings and the type of ring condensation. Information obtained is very different from that observed on hydrocarbon substrates, and thus these phases can be used in a complementary fashion to give a profile of polycyclic aromatics in shale oil samples. 7 figures, 1 table.

  2. [Influences of ion-suppressors on retention behaviors of nine food additives in reversed-phase high performance liquid chromatographic separation].

    PubMed

    Zhao, Yonggang; Chen, Xiaohong; Li, Xiaoping; Yao, Shanshan; Jin, Micong

    2011-10-01

    The influences of ion-suppressors on retention behaviors of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in reversed-phase high performance liquid chromatographic (RP-HPLC) separation were investigated. The organic modification effects of acids, i. e. , trifluoroacetic acid (TFA) and buffer salts, i. e. , TFA-ammonium acetate (AmAc) were studied emphatically. The relationships between retention factors of solutes and volume percentages of ion-suppressors in the mobile phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, separately. The separation of nine food additives was completed by a gradient elution with acetonitrile-TFA (0.01%, v/v)-AmAc (2. 5 mmol/L) aqueous solution as the mobile phases. An RP-HPLC method was established for the simultaneous determination of nine food additives in red wine. In the range of 10. 0 - 100. 0 mg/L, nine food additives showed good linearity with the correlation coefficients ( r2 ) larger than 0. 999 1. The limits of detection (LODs) were in the range of 0. 33 - 2. 36 mg/L and the limits of quantification (LOQs) were in the range of 1. 11 - 7. 80 mg/L. The spiked recoveries were between 87. 61% and 108. 4% with the relative standard deviations (RSDs) of 2. 2% -9. 4%. These results are of referential significance for the rapid establishment and accu- rate optimization of RP-HPLC separation for the simultaneous determination of food additives in other foods. PMID:22268355

  3. Comparison of different statistical approaches to evaluate the orthogonality of chromatographic separations: application to reverse phase systems.

    PubMed

    Al Bakain, Ramia; Rivals, Isabelle; Sassiat, Patrick; Thiébaut, Didier; Hennion, Marie-Claire; Euvrard, Guillaume; Vial, Jérôme

    2011-05-20

    Selectivity of phase system is of primary concern when designing a bidimensional chromatographic system and looking for the highest degree of orthogonality between the two separations. Several statistical or geometrical criteria can potentially be used to measure the degree of orthogonality. A comparison of eight candidate criteria has been carried out in this study. Analysis of variance (ANOVA) was used to evaluate the relevance of each criterion and its ability to reveal the significance of the influence of factors like pH, stationary phase, and organic modifier. Experimentally, a set of 32 chromatographic systems was evaluated by the same generic gradient with 63 probe solutes, likely to be present in biological and/or environmental samples and covering a wide range of physico-chemical properties: acidic, basic and neutral compounds with different pKa, molecular mass and hydrophobicity (logP). Each chromatographic system was defined by the nature of the stationary phase (8 different silica or grafting chemistries), the pH of the aqueous fraction of the mobile phase (2.5 or 7.0) and the nature of the organic modifier (acetonitrile or methanol). The orthogonality of the 496 couples of chromatographic systems was evaluated and ranked using the eight different approaches: the three correlation coefficients (Pearson, Spearman and Kendall), two geometric criteria characterizing the coverage of the 2D separation space, Slonecker's information similarity and two chi-square statistics of independence between normalized retention times. In fact, there were only seven distinct criteria, since we established the analytical equivalence between the rankings with the likelihood ratio statistics and Slonecker's information similarity. Kendall's correlation coefficient appeared to be the best measure of orthogonality since, according to ANOVA, it exhibited the highest sensitivity to all experimental factors. The chi-square measures, and hence Slonecker's information similarity

  4. New chromatographic materials for the separation and concentration of uranium from environmental matrices

    SciTech Connect

    Horwitz, E.P.; Dietz, M.L.; Chiarizia, R.; Diamond, H.

    1991-01-01

    Extraction chromatography, in which an inert support is impregnated with an extractant solution to form a chromatographic resin, combines the specificity of extraction with the ease of operation of an ion exchange column, thereby overcoming the principal drawbacks of the two methods when used alone. Previous work in this laboratory on the design of selective extractants for use in nuclear fuel reprocessing and in nuclear waste treatment has led to the development of several new phosphorus-based neutral organic extractants. In this report, we examine the use of two of these materials as stationary phases in extraction chromatography for the isolation of uranium from environmental samples. 2 refs., 2 figs., 1 tab.

  5. Comparison of nano and conventional liquid chromatographic methods for the separation of (+)-catechin-ethyl-malvidin-3-glucoside diastereoisomers.

    PubMed

    Kučera, Lukáš; Fanali, Salvatore; Aturki, Zeineb; Pospíšil, Tomáš; Bednář, Petr

    2016-01-01

    Nano-liquid chromatography and conventional HPLC were used for the separation of diastereomers of (+)-catechin-ethyl-malvidin-3-glucoside. Those bridged anthocyanin dyes were obtained by reaction of (+)-catechin with malvidin-3-glucoside in the presence of acetaldehyde. Both diastereomers were isolated with semipreparative chromatography and their structures were confirmed by nuclear magnetic resonance and mass spectrometry. In-laboratory prepared capillary columns packed with fully porous particles Chromosphere C18, dp=3μm, core-shell particles Kinetex C18, dp=2.6μm (100μm i.d.) and monolithic column Chromolith CapRod (100μm i.d.) were used for the separation of (+)-catechin, malvidin-3-glucoside and both diastereomers. Chromosphere C18 stationary phase provided the best chromatographic performance. Mobile phase containing water:acetonitrile (80:20) acidified with trifluoroacetic acid (0.1%, v/v/v) was used in an isocratic elution mode with a flow rate of 360nLmin(-1). Separation of studied compounds was achieved in less than 7min under optimized conditions. The nano-liquid chromatographic method and a conventional HPLC one using the same fully porous particles (Chromosphere C18, 3μm, 100mm×4.6mm) were compared providing higher separation efficiency with the first analytical method and similar selectivity. A better peak symmetry and higher resolution of the studied diastereomers was achieved by conventional chromatography. Nevertheless, nano-liquid chromatography appeared to be useful for the separation of complex anthocyanin dyes and can be utilized for their analysis in plant and food micro-samples. The developed method was used for analysis of red wine grape pomace. PMID:26433264

  6. A liquid chromatographic method for analysis of all-rac-alpha-tocopheryl acetate and retinyl palmitate in medical food using matrix solid-phase dispersion in conjunction with a zero reference material as a method development tool.

    PubMed

    Chase, G W; Eitenmiller, R R; Long, A R

    1999-01-01

    A liquid chromatographic method is described for analysis of all-rac-alpha-tocopheryl acetate and retinyl palmitate in medical food. The vitamins are extracted from medical food without saponification by matrix solid-phase dispersion and chromatographed by normal-phase chromatography with fluorescence detection. Retinyl palmitate and all-rac-alpha-tocopheryl acetate are quantitated isocratically with a mobile phase of 0.125% (v/v) and 0.5% (v/v) isopropyl alcohol in hexane, respectively. Results compared favorably with label declarations on retail medical foods. Recoveries determined on an analyte-fortified zero reference material for a milk-based medical food averaged 98.3% (n = 25) for retinyl palmitate spikes and 95.7% (n = 25) for all-rac-alpha-tocopheryl acetate spikes. Five concentrations were examined for each analyte, and results were linear (r2 = 0.995 for retinyl palmitate and 0.9998 for all-rac-alpha-tocopheryl acetate) over the concentration range examined, with coefficients of variation in the range 0.81-4.22%. The method provides a rapid, specific, and easily controlled assay for analysis of retinyl palmitate and all-rac-alpha-tocopheryl acetate in fortified medical foods. PMID:10028678

  7. Chromatographic cation exchange separation of decigram quantities of californium and other transplutonium elements

    SciTech Connect

    Benker, D.E.; Chattin, F.R.; Collins, E.D.; Knauer, J.B.; Orr, P.B.; Ross, R.G.; Wiggins, J.T.

    1980-01-01

    Decigram quantities of highly radioactive transplutonium elements are routinely partitioned at TRU by chromatographic elution from cation resin using AHIB eluent. By using two high-pressure ion exchange columns, a small one for the initial loading of the feed and a large one for the elution, batch runs containing up to 200 mg of /sup 252/Cf can be made in about 5 hours (2 hours to load the feed and 3 hours for the elution). The number of effluent product fractions and the amount of actinides that must be collected in intermediate fractions are minimized by monitoring response from a flow-through alpha-detector. This process has been reliable and relatively easy to operate, and will continue to be used for partitioning transplutonium elements at TRU.

  8. New reagents for enhanced liquid chromatographic separation and charging of intact protein ions for electrospray ionization mass spectrometry.

    PubMed

    Valeja, Santosh G; Tipton, Jeremiah D; Emmett, Mark R; Marshall, Alan G

    2010-09-01

    Electrospray ionization produces multiply charged ions, thereby lowering the mass-to-charge ratio for peptides and small proteins to a range readily accessed by quadrupole ion trap, orbitrap, and ion cyclotron resonance (ICR) mass analyzers (m/z = 400-2000). For Fourier transform mass analyzers (orbitrap and ICR), higher charge also improves signal-to-noise ratio, mass resolution, and mass accuracy. Addition of m-nitrobenzyl alcohol (m-NBA) or sulfolane has previously been shown to increase the charge states of proteins. Moreover, polar aprotic dimethylformamide (DMF) improves chromatographic separation of proteolytic peptides for mass analysis of solution-phase protein hydrogen/deuterium exchange for improved (78-96%) sequence coverage. Here, we show that addition of each of the various modifiers (DMF, thiodiglycol, dimethylacetamide, dimethylsulfoxide, and N-methylpyrrolidone) can significantly increase the charge states of proteins up to 78 kDa. Moreover, incorporation of the same modifiers into reversed-phase liquid chromatography solvents improves sensitivity, charging, and chromatographic resolution for intact proteins. PMID:20704305

  9. [Contamination mechanism and regeneration strategies of chromatographic resin in separation process for expression product from mammary gland bioreactor].

    PubMed

    Sun, Xiyan; Zhang, Yan; Li, Yan; Luo, Jian; Qin, Peiyong; Su, Zhiguo

    2011-11-01

    This study focused on the contamination mechanism and regeneration strategies of sulfopropyl ion exchange resin (SP Sepharose FF) during the separation of recombinant human lactoferrin from transgenic bovine milk. We analyzed primary constituents' contents in chromatorgraphic material and fractions. The results showed that the lipid in milk can clog the column or adhere to the resin through hydrophobic interaction, leading to an increase in column pressure. Some casein molecules were found to adsorb onto the resin through electrostatic interaction, therefore the adsorption capacity was decreased. There was no direct interaction between lactose and the resin in the chromatorgraphic process. Increased continuous chromatographic cycles and prolonged time interval between protein purification and column regeneration could enhance the undesirable interaction between the contaminants and resin, thus lowering the regeneration efficiency. NaOH was found to be effective in the removal of lipid and casein molecules from the column. Furthermore, normal microstructure and chromatographic performance of the ion exchanger was recovered after this cleaning procedure. PMID:22393720

  10. Superhydrophobic, Hybrid, Electrospun Cellulose Acetate Nanofibrous Mats for Oil/Water Separation by Tailored Surface Modification.

    PubMed

    Arslan, Osman; Aytac, Zeynep; Uyar, Tamer

    2016-08-01

    Electrospun cellulose acetate nanofibers (CA-NF) have been modified with perfluoro alkoxysilanes (FS/CA-NF) for tailoring their chemical and physical features aiming oil-water separation purposes. Strikingly, hybrid FS/CA-NF showed that perfluoro groups are rigidly positioned on the outer surface of the nanofibers providing superhydrophobic characteristic with a water contact angle of ∼155°. Detailed analysis showed that hydrolysis/condensation reactions led to the modification of the acetylated β(1 → 4) linked d-glucose chains of CA transforming it into a superhydrophobic nanofibrous mat. Analytical data have revealed that CA-NF surfaces can be selectively controlled for fabricating the durable, robust and water resistant hybrid electrospun nanofibrous mat. The -OH groups available on the CA structure allowed the basic sol-gel reactions started by the reactive FS hybrid precursor system which can be monitored by spectroscopic analysis. Since alkoxysilane groups on the perfluoro silane compound are capable of reacting for condensation together with the CA, superhydrophobic nanofibrous mat is obtained via electrospinning. This structural modification led to the facile fabrication of the novel oil/water nanofibrous separator which functions effectively demonstrated by hexane/oil and water separation experiments. Perfluoro groups consequently modified the hydrophilic CA nanofibers into superhydrophobic character and therefore FS/CA-NF could be quite practical for future applications like water/oil separators, as well as self-cleaning or water resistant nanofibrous structures. PMID:27398738

  11. Effect of evaporation time on cellulose acetate membrane for gas separation

    NASA Astrophysics Data System (ADS)

    Jami'an, W. N. R.; Hasbullah, H.; Mohamed, F.; Yusof, N.; Ibrahim, N.; Ali, R. R.

    2016-06-01

    Throughout this decades, membrane technology has been the desirable option among the others gas separation technologies. However, few issues have been raised regarding the membrane gas separation application including the trade-off between its permeability and selectivity and also its effects towards environment. Therefore, for this research, a biopolymer membrane for gas separation application will be developed with reasonably high on both permeability and selectivity. The main objective of this research is to study the effect of solvent evaporation time on the flat sheet asymmetric membrane morphology and gas separation performance. The membranes were produced by a simple dry/wet phase inversion technique using a pneumatically controlled casting system. The dope solution for the membrane casting was prepared by dissolving the cellulose acetate (CA) polymer in N-Methyl-2-pyrrolidone (NMP) and the solvent evaporation time was varied. Permeability and selectivity of the membrane was performed by using pure gases of carbon dioxide, CO2 and methane, CH4. The increase in solvent evaporation time had improved the membrane morphologies as the porosity of the membrane surface decrease and formation of a more mature skin layer. The gas permeation tests determined that increasing in solvent evaporation time had increased the selectivity of CO2/CH4 but reduce the permeability of both gases

  12. A Simple, Inexpensive, High Pressure Liquid Chromatographic Method for Separating Cytokinins in Plant Extracts

    PubMed Central

    Thomas, Tudor H.; Carroll, James E.; Isenberg, Francis M. R.; Pendergrass, Ann; Howell, Lydia

    1975-01-01

    Separation of a mixture of the main cytokinins occurring naturally in plant tissues was achieved by high pressure liquid chromatography using insoluble polyvinylpyrrolidone as the solid support. The separation of each cytokinin was first assessed over a range of salt and l-butanol concentrations and pH using a mixture of borate buffer and l-butanol as the mobile phase to determine the conditions necessary for optimum resolution. A discrete separation of zeatin, N-6-(Δ-2-isopentenyl)adenine, their related ribonucleosides, and kinetin was achieved using a simple isocratic elution with 0.025 m borate buffer at pH 6.8 and 4% (v/v) l-butanol. A number of cytokinin-active compounds were detected in cabbage extracts by the Amaranthus betacyanin bioassay using this separation technique. PMID:16659314

  13. Column chromatographic boron isotope separation at 5 and 17 MPa with diluted boric acid solution.

    PubMed

    Musashi, Masaaki; Oi, Takao; Matsuo, Motoyuki; Nomura, Masao

    2008-08-01

    Boron isotopic fractionation factor (S) between boron taken up in strongly basic anion exchange resin and boron in aqueous solution was determined by breakthrough column chromatography at 5 and 17 MPa at 25 degrees C, using 0.1 mM boric acid solution as feed solution. The S values obtained were 1.018 and 1.012, respectively, which were smaller than the value reported by using the same chromatographic method at the atmospheric pressure at 25 degrees C with the boron concentration of 10mM, but were larger than the values under the same condition with much higher concentration of 100 and 501 mM. Calculations based on the theory of isotope distribution between two phases estimated that 21% (5 MPa) and 47% (17 MPa) of boron taken up in the resin phase was in the three-coordinated B(OH)(3)-form, instead of in the four-coordinated B(OH)(4)-form, at high pressures even with a very diluted boric acid solution. We discussed the present results by introducing (1) hydration and (2) a partial molar volume difference between isotopic molecules. Borate may have been partially dehydrated upon transfer from the solution phase to the resin phase at high pressures, which resulted in smaller S values compared with those at the atmospheric pressure. Instead, it may be possible that the difference in the isotopic partial molar volume difference between B(OH)(3) and B(OH)(4)(-) caused the S value to decrease with increasing pressure. PMID:18585727

  14. Chromatographic separation of selenium and arsenic: A potential (72)Se/(72)As generator.

    PubMed

    Wycoff, Donald E; Gott, Matthew D; DeGraffenreid, Anthony J; Morrow, Ryan P; Sisay, Nebiat; Embree, Mary F; Ballard, Beau; Fassbender, Michael E; Cutler, Cathy S; Ketring, Alan R; Jurisson, Silvia S

    2014-05-01

    An anion exchange method was developed to separate selenium and arsenic for potential utility in a (72)Se/(72)As generator. The separation of the daughter (72)As from the (72)Se parent is based on the relative acid-base behavior of the two oxo-anions in their highest oxidation states. At pH 1.5, selenate is retained on strongly basic anion exchange resin as HSeO4(-) and SeO4(2-), while neutral arsenic acid, H3AsO4, is eluted. PMID:24679827

  15. Chromatographic Separation of Selenium and Arsenic: A Potential 72Se/72As Generator

    PubMed Central

    Wycoff, Donald E.; Gott, Matthew D.; DeGraffenreid, Anthony J.; Morrow, Ryan P.; Sisay, Nebiat; Embree, Mary F.; Ballard, Beau; Fassbender, Michael E.; Cutler, Cathy S.; Ketring, Alan R.; Jurisson, Silvia S.

    2014-01-01

    Summary An anion exchange method was developed to separate selenium and arsenic for potential utility in a 72Se/72As generator. The separation of the daughter 72As from the 72Se parent is based on the relative acid-base behavior of the two oxo-anions in their highest oxidation states. At pH 1.5, selenate is retained on strongly basic anion exchange resin as HSeO4− and SeO42−, while neutral arsenic acid, H3AsO4, is eluted. PMID:24679827

  16. 34 GHz EPR FTIR spectra of chromatographically separated Boscan asphaltene fractions

    SciTech Connect

    Malhotra, V.M. ); Buckmaster, H.A. )

    1989-03-01

    The authors report on their re-examination of the 34 GHz and Fourier transform infrared (FTIR) measurements on three fractions of Boxcan asphaltene separated by the gel permeation chromatography (GPC) technique. The authors attempted to determine various types of vanadium coordination in GPC fractions by their partial combustion and subsequent EPR AND FTIR measurements.

  17. IMPROVED THIN-LAYER CHROMATOGRAPHIC SEPARATION OF 32P-POSTLABELING DNA ADDUCTS

    EPA Science Inventory

    DNA adducts represent the putative initiating event in the chemical process. 2P-Postlabeling is one of several assayswhich have been developed for the sensitive detection of DNA adducts. n integral part of the 32p-postlabeling assay is the separation of adducted nucleotides by mu...

  18. A new two-dimensional chromatographic method for separation of saponins from steamed Panax notoginseng.

    PubMed

    Lelu, Jimmy K; Liu, Qi; Alolga, Raphael N; Fan, Yong; Xiao, Wei-Lie; Qi, Lian-Wen; Li, Ping

    2016-06-01

    The root and rhizome of Panax notoginseng (PNG) are used as folk medicine. Recent studies have reported PNG to possess immunomodulatory, cardioprotective, hepatoprotective, anti-diabetic and anticancer activities among a host of other pharmacological effects. The main active constituents responsible for these pharmacological effects are saponins. It has also been proven that the chemical constituents of steamed PNG differs from the raw form. Traditional methods of separating individual components in crude extracts are usually tedious, almost irreproducible and time-consuming. In this study, an automated multi-step preparative separation system, known as Sepbox afforded a quick, reproducible and fast separation of saponins from PNG. With Sepbox, a total of 11 saponins of high purity were obtained in a short period of time. The separated compounds were identified as notoginsenosides R1, T5, ginsenosides Rb1, Rg1, Rg2, Rh1, Rh4, Rd, 20 (S) -Rg3 and a mixture of ginsenosides Rk1 and Rg5. PMID:27107214

  19. Ion-exchange chromatographic separation of einsteinium from irradiated californium targets

    SciTech Connect

    Elesin, A.A.; Nikolaev, V.M.; Shalimov, V.V.; Popov, Yu.S.; Kovantsev, V.N.; Tselishchev, I.V.; Filimonov, V.T.; Mishenev, V.B.; Yadovin, A.A.; Golosovskii, L.S.; Chetverikov, A.P.

    1987-07-01

    Einsteinium was obtained by preparing two experimental californium targets and subjecting them to neutron irradiation in a high-flux reactor. The einsteinium was separated from the bombarded targets on a column packed with KU-2U sulfonated cation-exchange resin (20-50 ..mu..m) and eluted at room temperature with an ammonium ..cap alpha..-hydroxyisobutyrate solution. Three successive separation cycles removed californium to produce einsteinium in 68% yield with a decontamination factor of 5.3 x 10/sup 6/. About 20% of the einsteinium was used up by analysis and 11% remained in intermediate fractions. The method developed yielded pure einsteinium with little fission products present. The contribution of the fission products to the total einsteinium gamma-irradiation dose rate was no greater than 81%, due primarily to the radioisotope terbium-160.

  20. A low-power pressure-and temperature-programmed separation system for a micro gas chromatograph.

    SciTech Connect

    Sacks, Richard D. (University of Michigan, Ann Arbor, MI); Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Lambertus, Gordon R. (University of Michigan, Ann Arbor, MI); Potkay, Joseph A. (University of Michigan, Ann Arbor, MI); Wise, Kensall D. (University of Michigan, Ann Arbor, MI)

    2006-10-01

    This thesis presents the theory, design, fabrication and testing of the microvalves and columns necessary in a pressure- and temperature-programmed micro gas chromatograph ({micro}GC). Two microcolumn designs are investigated: a bonded Si-glass column having a rectangular cross section and a vapor-deposited silicon oxynitride (Sion) column having a roughly circular cross section. Both microcolumns contain integrated heaters and sensors for rapid, controlled heating. The 3.2 cm x 3.2 cm, 3 m-long silicon-glass column, coated with a non-polar polydimethylsiloxane (PDMS) stationary phase, separates 30 volatile organic compounds (VOCs) in less than 6 min. This is the most efficient micromachined column reported to date, producing greater than 4000 plates/m. The 2.7 mm x 1.4 mm Sion column eliminates the glass sealing plate and silicon substrate using deposited dielectrics and is the lowest power and fastest GC column reported to date; it requires only 11 mW to raise the column temperature by 100 C and has a response time of 11s and natural temperature ramp rate of 580 C/min. A 1 m-long PDMS-coated Sion microcolumn separates 10 VOCs in 52s. A system-based design approach was used for both columns.

  1. Insights into chromatographic separation using core-shell metal-organic frameworks: Size exclusion and polarity effects.

    PubMed

    Qin, Weiwei; Silvestre, Martin E; Kirschhöfer, Frank; Brenner-Weiss, Gerald; Franzreb, Matthias

    2015-09-11

    Porous metal-organic frameworks (MOFs) [Cu3(BTC)2(H2O)3]n (also known as HKUST-1; BTC, benzene-1,3,5-tricarboxylic acid) were synthesized as homogeneous shell onto carboxyl functionalized magnetic microparticles through a liquid phase epitaxy (LPE) process. The as-synthesized core-shell HKUST-1 magnetic microparticles composites were characterized by XRD and SEM, and used as stationary phase in high performance liquid chromatography (HPLC). The effects of the unique properties of MOFs onto the chromatographic performance are demonstrated by the experiments. First, remarkable separation of pyridine and bipyridine is achieved, although both molecules show a strong interaction between the Cu-ions in HKUST-1 and the nitrogen atoms in their heterocyles. The difference can be explained due to size exclusion of bipyridine from the well defined pore structure of crystalline HKUST-1. Second, the enormous variety of possible interactions of sample molecules with the metal ions and linkers within MOFs allows for specifically tailored solid phases for challenging separation tasks. For example, baseline separation of three chloroaniline (CLA) isomers tested can be achieved without the need for gradient elution modes. Along with the experimental HPLC runs, in-depth modelling with a recently developed chromatography modelling software (ChromX) was applied and proofs the software to be a powerful tool for exploring the separation potential of thin MOF films. The pore diffusivity of pyridine and CLA isomers within HKUST-1 are found to be around 2.3×10(-15)m(2)s(-1). While the affinity of HKUST-1 to the tested molecules strongly differs, the maximum capacities are in the same range, with 0.37molL(-1) for pyridine and 0.23molL(-1) for CLA isomers, corresponding to 4.0 and 2.5 molecules per MOF unit cell, respectively. PMID:26277028

  2. Discovery of active components in herbs using chromatographic separation coupled with online bioassay.

    PubMed

    De-Qiang, Li; Zhao, Jing; Wu, Dong; Shao-Ping, Li

    2016-05-15

    Discovery of bioactive compounds from complex mixtures is a challenge. In past decades, several strategies were developed and implemented for rapid and effective screening and characterization of bioactive components in complex matrices. This review mainly focused on the online strategies, which integrated the separation science, mass spectrometry, and bioactivity screening in a single platform, allowing simultaneous screening and characterization of active compounds from complex matrices, especially from the herbs. The online screening methodologies, including pre-column affinity-based screening and post-column bioassay, were discussed and their applied examples were also presented to illustrate the strengths and limitations of these approaches. PMID:26896311

  3. Calix[4]pyrroles: highly selective stationary phases for gas chromatographic separations.

    PubMed

    Fan, Jing; Wang, Zhenzhong; Li, Qian; Qi, Meiling; Shao, Shijun; Fu, Ruonong

    2014-10-01

    Calix[4]pyrroles offer a great potential as stationary phases for gas chromatography (GC) due to their unique structures and physicochemical properties. Herein we present the first report of using two calix[4]pyrroles, namely meso-tetra-cyclohexylcalix[4]pyrrole (THCP) and meso-octamethylcalix[4]pyrrole (OMCP). These stationary phases were statically coated onto capillary columns and investigated in terms of column efficiency, polarity, separation performance, thermal stability and repeatability. The columns achieved column efficiencies of 2200-3000plates/m and exhibited nonpolar nature with an average polarity of 67 for THCP and 64 for OMCP, respectively. THCP stationary phase shows high selectivity for analytes of different polarity and exhibits nice peak shapes, especially for aldehydes, alcohols and anilines that are prone to severe peak tailing in GC analysis. Interestingly, THCP stationary phase possesses superior resolving ability for aniline and benzenediol positional isomers while OMCP shows preferential selectivity for nonpolar analytes such as hexane isomers. Moreover, calix[4]pyrrole columns also have good thermal stability up to 260°C and repeatability with a relative standard deviation (RSD%) of less than 0.10% for run-to-run and less than 5.2% for column-to-column. This work demonstrates the unique separation performance of calix[4]pyrroles and their promising future as a new class of GC stationary phases. PMID:25173993

  4. An experimental design approach to optimization of the liquid chromatographic separation conditions for the determination of metformin and glibenclamide in pharmaceutical formulation.

    PubMed

    Demiralay, Ebru Çubuk

    2012-06-01

    An optimization methodology is introduced for investigating the retention behavior and the separation factor of metformin, gliclazide (I.S.) and glibenclamide. This investigation has been focused on studying the influence of pH value of the mobile phase, concentration of acetonitrile and column temperature, which affect a complete separation of the chromatographic peaks of these compounds. The significant factors were optimized using full factorial design. Retention factor and separation factor were chosen as dependent variable. Optimum RP-LC chromatographic conditions for the separation of metformin, glibenclamide and gliclazide were obtained using X Terra column (150 mm × 4.6 mm I.D., 5 µm). The results show that the percentage of acetonitrile are the most important to investigate and sspH of the mobile phase and column temperature do not significantly affect the experimental results. The procedure was validated for linearity, accuracy, precision and recovery. Quantitation was accomplished using internal standard method. PMID:24061246

  5. Rapid preparation and characterization of methacrylate-based monoliths for chromatographic and electrophoretic separation.

    PubMed

    Fan, Li-Qun; Zhang, Yu-Ping; Gong, Wen-Jun; Qu, Ling-Bo; Lee, Kwang-Pill

    2010-01-01

    Butyl-methacrylate-based porous monoliths were rapidly prepared in the fused-silica capillary with a 10-cm stripe of polyimide removed from its exterior. The photopolymerization could be carried out in 150 s using ethylene glycol dimethacrylate as a cross-linking agent; 1-propanol, 1,4-butanediol, and water as tri-porogenic solvents; and Irgacure 1800 as a photo-initiator. The effect of different morphologies on the efficiency and retention properties was investigated using pressure-assisted CEC (p-CEC), CEC, and low pressure-assisted liquid chromatography modes (LPLC). Baseline separation of the model analytes was respectively achieved including thiourea, toluene, naphthalene, and biphenyl with the lowest theoretical height up to 8.0 microm for thiourea in the mode of p-CEC. Furthermore, the influence of the tri-porogenic solvents on the morphology of methacrylate-based monoliths was systematically studied with mercury intrusion porosimetry and scanning electron microscopy. PMID:20515536

  6. Comprehensive two-dimensional gas chromatographic separations with a temperature programmed microfabricated thermal modulator.

    PubMed

    Collin, William R; Nuñovero, Nicolas; Paul, Dibyadeep; Kurabayashi, Katsuo; Zellers, Edward T

    2016-04-29

    Comprehensive two-dimensional gas chromatography (GC×GC) with a temperature-programmed microfabricated thermal modulator (μTM) is demonstrated. The 0.78 cm(2), 2-stage μTM chip with integrated heaters and a PDMS coated microchannel was placed in thermal contact with a solid-state thermoelectric cooler and mounted on top of a bench scale GC. It was fluidically coupled through heated interconnects to an upstream first-dimension ((1)D) PDMS-coated capillary column and a downstream uncoated capillary or second-dimension ((2)D) PEG-coated capillary. A mixture of n-alkanes C6-C10 was separated isothermally and the full-width-at-half-maximum (fwhm) values of the modulated peaks were assessed as a function of the computer-controlled minimum and maximum stage temperatures of μTM, Tmin and Tmax, respectively. With Tmin and Tmax fixed at -25 and 100°C, respectively, modulated peaks of C6 and C7 had fwhm values<53 ms while the modulated peaks of C10 had a fwhm value of 1.3s, due to inefficient re-mobilization. With Tmin and Tmax fixed at 0 and 210°C, respectively, the fwhm value for the modulated C10 peaks decreased to 67 ms, but C6 and C7 exhibited massive breakthrough. By programming Tmin from -25 to 0°C and Tmax from 100 to 220°C, the C6 and C7 peaks had fwhm values≤50 ms, and the fwhm for C10 peaks remained<95 ms. Using the latter conditions for the GC×GC separation of a sample of unleaded gasoline yielded resolution similar to that reported with a commercial thermal modulator. Replacing the PDMS phase in the μTM with a trigonal-tricationic room temperature ionic liquid eliminated the bleed observed with the PDMS, but also reduced the capacity for several test compounds. Regardless, the demonstrated capability to independently temperature program this low resource μTM enhances its versatility and its promise for use in bench-scale GC×GC systems. PMID:27036209

  7. Optimization of extraction procedure and chromatographic separation of glyphosate, glufosinate and aminomethylphosphonic acid in soil.

    PubMed

    Druart, Coline; Delhomme, Olivier; de Vaufleury, Annette; Ntcho, Evodie; Millet, Maurice

    2011-02-01

    Analysing herbicides in soil is a complex issue that needs validation and optimization of existing methods. An extraction and analysis method was developed to assess concentrations of glyphosate, glufosinate and aminomethylphophonic acid (AMPA) in field soil samples. After testing extractions by accelerated solvent extraction and ultrasonic extraction, agitation was selected with the best recoveries. Water was preferred as solvent extraction because it resulted in a cleaner chromatogram with fewer impurities than was the case with alkaline solvents. Analysis was performed by FMOC pre-column derivatization followed by high-performance liquid chromatography (HPLC) on a 300 mm C(18) column which permitted enhanced separation and sensitivity than a 250 mm C(18) column and increased resistance than the NH(2) column for soil samples. This extraction and analysis method allowing a minimum of steps before the injection in the HPLC with fluorescence detection is efficient and sensitive for a clay-loamy soil with detection limits of 103 μg kg(-1) for glyphosate, 15 μg kg(-1) for glufosinate and 16 μg kg(-1) for AMPA in soil samples. PMID:21153586

  8. Evaluation of sample preparation and chromatographic separation for the parallel determination of taurine and edaravone in rat tissues using HILIC-MS/MS.

    PubMed

    Li, Yin-jie; Li, Zheng; Zheng, Xiao-xiao; Wu, Xiao-wen; Wang, Shi-rui; Guo, Hao; Yu, Yan-yan; Guo, Meng-zhe; Yan, Dong-zhi; Tang, Dao-quan

    2015-05-01

    The quantitative analysis of taurine and edaravone in biological sample is critical in pharmaceutical studies. Although each of them can be individually analyzed by different approaches, concurrent quantification is still a highly challenging task with respect to their great polarity variation and the complex composition of tissue sample. In the present study, to simultaneously determine taurine and edaravone in rat tissue, the sample preparation and chromatographic separation conditions were evaluated and discussed in detail. As for the sample preparation, four kinds of solvent and the volume ratio of the optimal solvent to biological sample were both tested and evaluated based on the chromatographic profile, extraction recovery, and matrix effect (ME). The chromatographic separation was performed in a reverse phase (RP) and two hydrophilic interaction liquid chromatography (HILIC) modes, and the corresponding separation efficiencies were assessed using chromatographic parameters like half-width (W 1/2 ), tailing factor (f t), theoretical plates number (N), and ME. Furthermore, adopted composition of two mobile phase systems and the concentrations of the additives in the optimum buffer system were also investigated on an Atlantis HILIC silica column according to the resultant chromatographic profiles and peak areas of the analytes. The optimal results were obtained when the biological samples were deproteined by 4-fold volume of methanol/acetonitrile (1:3, v/v) and separated on a HILIC column with a gradient elution of acetonitrile/water containing 0.2 % formic acid and 10 mM ammonium formate. The proposed approach was validated and successfully applied to the parallel determination of the tissue distribution of edaravone and taurine in rat tissues. PMID:25855151

  9. Efficient optimization of ultra-high- performance supercritical fluid chromatographic separation of Rosa sericea by response surface methodology.

    PubMed

    Li, Jin-Rong; Li, Min; Xia, Bing; Ding, Li-Sheng; Xu, Hong-Xi; Zhou, Yan

    2013-07-01

    An approach for rapid optimization of ultra-high-performance supercritical fluid chromatographic (UHPSFC) gradient by response surface methodology was developed for fast separation of complex crude extracts of the leaves of Rosa sericea. The optimization was performed with Box-Behnken designs and the multicriteria response variables were described using Derringer's desirability. Based on factorial design experiments, five factors were selected for Box-Behnken designs to optimize the UHPSFC conditions, which led to 46 experiments being performed within 8 h. An evaporative light-scattering detector (ELSD) was used, and quantitative analysis of main components in R. sericea samples was employed to evaluate the statistical significance of the parameters on UHPSFC-ELSD analytes response. The results indicated that the optimized UHPSFC-ELSD method is very sensitive with LODs and LOQs below 1.19 and 4.55 μg/mL, respectively. The overall intra- and interday variations were less than 3.91 and 6.41%, respectively. The recovery of the method ranged from 95.66 to 104.22%, with RSD < 5.91%. This newly developed UHPSFC-ELSD method was demonstrated to be fast and sensitive in analyzing complex herbal extracts of Traditional Chinese Medicines. PMID:23625629

  10. Fast chromatographic separation for the quantitation of the main flavone dyes in Reseda luteola (weld).

    PubMed

    Villela, Alexandre; van der Klift, Elbert J C; Mattheussens, Eric S G M; Derksen, Goverdina C H; Zuilhof, Han; van Beek, Teris A

    2011-11-25

    In the past decades, there has been a renewed interest in the use of natural dye plants for textile dyeing, e.g. Reseda luteola (weld). Its main yellow dye constituents are the flavones luteolin-7,3'-O-diglucoside, luteolin-7-O-glucoside and luteolin. The aim of this work was to develop a simple validated industrially usable quantitative method to assess the flavone content of R. luteola samples. The flavones were overnight extracted from the dried and ground aerial parts of the plant at room temperature via maceration with methanol-water 8:2. Afterwards, they were quantified through internal standardisation against chrysin by RP-HPLC-UV at 345 nm. The efficiency of the one-step extraction was 95%. The limits of detection (LOD) and quantitation (LOQ) were ≤ 1 ng and ≤ 3 ng, respectively, providing ample sensitivity for the purpose. The precision expressed as relative standard deviation of the entire method was <6.5% for the combined content of luteolin-7,3'-O-diglucoside, luteolin-7-O-glucoside and luteolin. The average absolute recovery (accuracy) at three spiking levels was 102% (range: 98-107%) and the relative recovery ranged from 99 to 102%. The separation was initially carried out on a traditional 250 mm × 4.6 mm 5 μm HPLC column (80 min run time, 35.9 mL MeOH). It was then speeded up by the use of a 50 mm × 3.0mm 1.8 μm UHPLC column (5 min run time, 1.4 mL MeCN), while still using a conventional HPLC system. Whereas, the retention times on the UHPLC column were relatively less reproducible, cross-validation showed that the quantitation of luteolin-7,3'-O-diglucoside, luteolin-7-O-glucoside and luteolin was not statistically significantly different, with comparable precision. The method using the UHPLC column is more sensitive. The analytical method described meets the demand for a very small manpower input per sample and uses standard laboratory equipment. Usage of short UHPLC columns opens up interesting possibilities for modernising HPLC

  11. Highly Porous Regenerated Cellulose Fiber Mats via the Co-Forcespinning of Cellulose Acetate for Separator Applications

    NASA Astrophysics Data System (ADS)

    Castillo, Alejandro; Mao, Yuanbing

    2015-03-01

    Improvements in battery technology are necessary for the transition away from a fossil fuel based economy. An important bottle-neck in battery efficiency is the quality of the separator, which separates the cathode and anode to prevent a short-circuit while still allowing the ions in solution to flow as close to unabated as possible. In this work solutions of cellulose acetate, polyvinyldiflourine (pvdf), and polyvinylpyrrolidone (pvp) dissolved in a 2:1 v/v acetone/dimethylacetamide solvent mixture were Forcespun to create nonwoven fiber mats of nanoscale diameter. These mats were then soaked in a NaOH solution so as to both strip the pvp from the fiber as well as regenerate cellulose from its acetate derivative for the purpose of creating high surface area, nanoporous, hydrophilic, and ioniclly conductive cellulose/pvdf nonwoven mats for the purposes of testing their suitability as battery separators

  12. Determination of rare earth impurities in high purity samarium oxide using inductively coupled plasma mass spectrometry after extraction chromatographic separation

    NASA Astrophysics Data System (ADS)

    Zhang, Xinquan; Liu, Jinglei; Yi, Yong; Liu, Yonglin; Li, Xiang; Su, Yaqin; Lin, Ping

    2007-01-01

    A method for the determination of trace of 14 rare earth elements (REEs) as impurities in high purity samarium oxide (Sm2O3) using inductively coupled plasma mass spectrometry (ICP-MS) was described. Analytes, such as La, Ce, Pr, Nd, Eu, Gd, Tb, Lu and Y were measured without Sm matrix separation because of no interference problems occurring that could affect the analysis of these elements. On the other hand, analytes, such as Dy, Ho, Er, Tm and Yb were carried out after Sm matrix being eliminated completely by means of 2-ethylhexyl hydrogen-ethylhexy phosphonate (EHEHP) extraction chromatographic separation. The inherent problem associated with matrix-induced suppression was effectively compensated with spiking In as internal standard element and the mass spectra isobaric interferences of atomic and molecular ions arose from Sm matrix had been overcome after the removal of Sm matrix. The limits of quantitations (LOQ) for 14 REEs impurities were from 0.01 to 0.07 [mu]g g-1 together with the recoveries of spiking sample of 14 REEs were found to be in the range of 85-110% and the proposed method precision was less than 5%. A synthetic standard Sm2O3 sample with well-known 14 REEs concentrations was prepared and analysed in order to prove the accuracy and precision of the proposed method together with another high purity Sm2O3 was also measured using ICP-MS. The methodology had been found to be suitable for the determination of trace of 14 REEs in 99.999-99.9999% high purity Sm2O3.

  13. QbD-oriented development and validation of a bioanalytical method for nevirapine with enhanced liquid-liquid extraction and chromatographic separation.

    PubMed

    Beg, Sarwar; Chaudhary, Vandna; Sharma, Gajanand; Garg, Babita; Panda, Sagar Suman; Singh, Bhupinder

    2016-06-01

    The present studies describe the systematic quality by design (QbD)-oriented development and validation of a simple, rapid, sensitive and cost-effective reversed-phase HPLC bioanalytical method for nevirapine in rat plasma. Chromatographic separation was carried out on a C18 column using isocratic 68:9:23% v/v elution of methanol, acetonitrile and water (pH 3, adjusted by orthophosphoric acid) at a flow rate of 1.0 mL/min using UV detection at 230 nm. A Box-Behnken design was applied for chromatographic method optimization taking mobile phase ratio, pH and flow rate as the critical method parameters (CMPs) from screening studies. Peak area, retention time, theoretical plates and peak tailing were measured as the critical analytical attributes (CAAs). Further, the bioanalytical liquid-liquid extraction process was optimized using an optimal design by selecting extraction time, centrifugation speed and temperature as the CMPs for percentage recovery of nevirapine as the CAA. The search for an optimum chromatographic solution was conducted through numerical desirability function. Validation studies performed as per the US Food and Drug Administration requirements revealed results within the acceptance limit. In a nutshell, the studies successfully demonstrate the utility of analytical QbD approach for the rational development of a bioanalytical method with enhanced chromatographic separation and recovery of nevirapine in rat plasma. Copyright © 2015 John Wiley & Sons, Ltd. PMID:26352459

  14. Improved high performance liquid chromatographic separation of anthocyanin compounds from grapes using a novel mixed-mode ion-exchange reversed-phase column.

    PubMed

    McCallum, Jason L; Yang, Raymond; Young, J Christopher; Strommer, Judith N; Tsao, Rong

    2007-04-27

    A novel mixed mode HPLC method using a column combining both ion-exchange and reversed-phase separation mechanisms has been developed to facilitate analysis of anthocyanins in grapes. Chromatographic performance and subsequent analysis of anthocyanidin diglucosides and acylated compounds are significantly improved using the new column, compared to those associated with conventional C18 reversed-phase methods. The mixed mode column produces a distinctive eluting pattern for the different anthocyanin subgroups, avoiding overlaps found with C18 columns. The enhanced chromatographic resolution provides nearly complete separation of 37 anthocyanin types, and permits detection of delphinidin 3-O-(6''-O-caffeoyl) beta-D-glucoside for the first time in extracts of skins from Concord grapes. PMID:17382950

  15. Incorporation of metal-organic framework HKUST-1 into porous polymer monolithic capillary columns to enhance the chromatographic separation of small molecules.

    PubMed

    Yang, Shengchao; Ye, Fanggui; Lv, Qinghui; Zhang, Cong; Shen, Shufen; Zhao, Shulin

    2014-09-19

    Metal-organic framework (MOF) HKUST-1 nanoparticles have been incorporated into poly(glycidyl methacrylate-co-ethylene dimethacrylate) (HKUST-1-poly(GMA-co-EDMA)) monoliths to afford stationary phases with enhanced chromatographic performance of small molecules in the reversed phase capillary liquid chromatography. The effect of HKUST-1 nanoparticles in the polymerization mixture on the performance of the monolithic column was explored in detail. While the bare poly(GMA-co-EDMA) monolith exhibited poor resolution (Rs<1.0) and low efficiency (800-16,300plates/m), addition of a small amount of HKUST-1 nanoparticles to the polymerization mixture provide high increased resolution (Rs≥1.3) and high efficiency ranged from 16,300 to 44,300plates/m. Chromatographic performance of HKUST-1-poly(GMA-co-EDMA) monolith was demonstrated by separation of various analytes including polycyclic aromatic hydrocarbons, ethylbenzene and styrene, phenols and aromatic acids using a binary polar mobile phase (CH3CN/H2O). The HKUST-1-poly(GMA-co-EDMA) monolith displayed enhanced hydrophobic and π-π interaction characteristics in the reversed phase separation of test analytes compared to the bare poly(GMA-co-EDMA) monolith. The experiment results showed that HKUST-1-poly(GMA-co-EDMA) monoliths are an alternative to enhance the chromatographic separation of small molecules. PMID:25145567

  16. Comparative studies of peak intensities and chromatographic separation of proteolytic digests, PTMs, and intact proteins obtained by nanoLC-ESI MS analysis at room and elevated temperatures.

    PubMed

    Moskovets, Eugene V; Ivanov, Alexander R

    2016-06-01

    This work demonstrates that the chromatographic separation performed at highly stabilized elevated temperature results in significant improvements in sensitivity, quantitative accuracy, chromatographic resolution, and run-to-run reproducibility of nanoLC-MS analysis of complex peptides mixtures. A newly developed platform was shown to provide conditions for accurate temperature stabilization and temperature homogeneity when performing nanoLC-ESI MS analysis. We quantitatively assessed and compared the recovery of peptides and small proteins from nanoLC columns at room and elevated temperatures. We found that analyses performed at highly stabilized elevated temperatures led to improved detection sensitivity, reproducibility, and chromatographic resolution in reversed-phase LC separation of unmodified peptides (both hydrophilic and hydrophobic), post-translationally modified peptides (O-phosphorylated), and small intact proteins. The analytical benefits of elevated temperatures for qualitative and quantitative proteomic LC-MS profiling were demonstrated using mixtures of synthetic peptides, tryptic digests of mixtures of model proteins, and digested total lysates of isolated rat kidney mitochondria. The effect of elevated temperature on the ion suppression was also demonstrated. Graphical Abstract A fragment of overlaid LC retention time-m/z planar views demonstrates the improved separation performance in the analysis of a complex peptide mixture at elevated temperature. Retention time-m/z 2D peptide features detected at 60 °C (magenta) were matched and aligned with features detected at room temperature (green). PMID:26898204

  17. High-resolution hydrodynamic chromatographic separation of large DNA using narrow, bare open capillaries: a rapid and economical alternative technology to pulsed-field gel electrophoresis?

    PubMed

    Liu, Lei; Veerappan, Vijaykumar; Pu, Qiaosheng; Cheng, Chang; Wang, Xiayan; Lu, Liping; Allen, Randy D; Guo, Guangsheng

    2014-01-01

    A high-resolution, rapid, and economical hydrodynamic chromatographic (HDC) method for large DNA separations in free solution was developed using narrow (5 μm diameter), bare open capillaries. Size-based separation was achieved in a chromatographic format with larger DNA molecules being eluting faster than smaller ones. Lambda DNA Mono Cut Mix was baseline-separated with the percentage resolutions generally less than 9.0% for all DNA fragments (1.5 to 48.5 kbp) tested in this work. High efficiencies were achieved for large DNA from this chromatographic technique, and the number of theoretical plates reached 3.6 × 10(5) plates for the longest (48.5 kbp) and 3.7 × 10(5) plates for the shortest (1.5 kbp) fragments. HDC parameters and performances were also discussed. The method was further applied for fractionating large DNA fragments from real-world samples (SacII digested Arabidopsis plant bacterial artificial chromosome (BAC) DNA and PmeI digested Rice BAC DNA) to demonstrate its feasibility for BAC DNA finger printing. Rapid separation of PmeI digested Rice BAC DNA covering from 0.44 to 119.041 kbp was achieved in less than 26 min. All DNA fragments of these samples were baseline separated in narrow bare open capillaries, while the smallest fragment (0.44 kbp) was missing in pulsed-field gel electrophoresis (PFGE) separation mode. It is demonstrated that narrow bare open capillary chromatography can realize a rapid separation for a wide size range of DNA mixtures that contain both small and large DNA fragments in a single run. PMID:24274685

  18. [Development of an automatic vacuum liquid chromatographic device and its application in the separation of the components from Schisandra chinensis (Turz) Baill].

    PubMed

    Zhu, Jingbo; Liu, Baoyue; Shan, Shibo; Ding, Yanl; Kou, Zinong; Xiao, Wei

    2015-08-01

    In order to meet the needs of efficient purification of products from natural resources, this paper developed an automatic vacuum liquid chromatographic device (AUTO-VLC) and applied it to the component separation of petroleum ether extracts of Schisandra chinensis (Turcz) Baill. The device was comprised of a solvent system, a 10-position distribution valve, a 3-position changes valve, dynamic axis compress chromatographic columns with three diameters, and a 10-position fraction valve. The programmable logic controller (PLC) S7- 200 was adopted to realize the automatic control and monitoring of the mobile phase changing, column selection, separation time setting and fraction collection. The separation results showed that six fractions (S1-S6) of different chemical components from 100 g Schisandra chinensis (Turcz) Baill. petroleum ether phase were obtained by the AUTO-VLC with 150 mm diameter dynamic axis compress chromatographic column. A new method used for the VLC separation parameters screened by using multiple development TLC was developed and confirmed. The initial mobile phase of AUTO-VLC was selected by taking Rf of all the target compounds ranging from 0 to 0.45 for fist development on the TLC; gradient elution ratio was selected according to k value (the slope of the linear function of Rf value and development times on the TLC) and the resolution of target compounds; elution times (n) were calculated by the formula n ≈ ΔRf/k. A total of four compounds with the purity more than 85% and 13 other components were separated from S5 under the selected conditions for only 17 h. Therefore, the development of the automatic VLC and its method are significant to the automatic and systematic separation of traditional Chinese medicines. PMID:26749864

  19. Refined separation of combined Fe–Hf from rock matrices for isotope analyses using AG-MP-1M and Ln-Spec chromatographic extraction resins

    PubMed Central

    Cheng, Ting; Nebel, Oliver; Sossi, Paolo A.; Chen, Fukun

    2014-01-01

    A combined procedure for separating Fe and Hf from a single rock digestion is presented. In a two-stage chromatographic extraction process, a purified Fe fraction is first quantitatively separated from the rock matrix using AG-MP-1M resin in HCl. Hafnium is subsequently isolated using a modified version of a commonly applied method using Eichrom LN-Spec resin. Our combined method includes:•Purification of Fe from the rock matrix using HCl, ready for mass spectrometric analysis.•Direct loading of the matrix onto the resin that is used for Hf purification.•Collection of a Fe-free Hf fraction. PMID:26150946

  20. Low cost hydrogen/novel membrane technology for hydrogen separation from synthesis gas, Phase 1. [Polyetherimide, cellulose acetate and ethylcellulose

    SciTech Connect

    Not Available

    1986-01-01

    The goal of this program is to develop polymer membranes useful in the preparation of hydrogen from coal-derived synthesis gas. During this quarter the first experiment were aimed at developing high performance composite membranes for the separation of hydrogen from nitrogen and carbon monoxide. Three polymers have been selected as materials for these membranes: polyetherimide cellulose acetate and ethylcellulose. This quarter the investigators worked on polyetherimide and cellulose acetate membranes. The overall structure of these membranes is shown schematically in Figure 1. As shown, a microporous support membrane is first coated with a high flux intermediate layer then with an ultrathin permselective layer and finally, if necessary, a thin protective high flux layer. 1 fig., 4 tabs.

  1. Total Synthesis of Acetate from CO2: Methyltetrahydrofolate, an Intermediate, and a Procedure for Separation of the Folates

    PubMed Central

    Parker, Donald J.; Wu, Tsai-Feng; Wood, Harland G.

    1971-01-01

    Whole-cell preparations of Clostridium thermoaceticum were exposed to a short pulse of 14CO2 under conditions in which double-labeled acetate was synthesized. Radioactive methyltetrahydrofolate monoglutamate, diglutamate, and triglutamates were isolated from extracts of the cells. The radioactivity was found to be exclusively in the five methyl position. The specific activities of the methyltetrahydrofolate derivatives were very high and were in accord with the proposal that methyltetrahydrofolates are the precursors of the methyl of acetate. A new method of separation of folates employing QAE-Sephadex chromatography and a linear gradient with triethylammonium bicarbonate is presented which completely resolves the common folate monoglutamates and, upon freeze-drying, yields salt-free preparations. PMID:5001869

  2. Determination of methylmercury and inorganic mercury by coupling short-column ion chromatographic separation, on-line photocatalyst-assisted vapor generation, and inductively coupled plasma mass spectrometry.

    PubMed

    Chen, Kuan-ju; Hsu, I-hsiang; Sun, Yuh-chang

    2009-12-18

    We have combined short-column ion chromatographic separation and on-line photocatalyst-assisted vapor generation (VG) techniques with inductively coupled plasma mass spectrometry to develop a simple and sensitive hyphenated method for the determination of aqueous Hg(2+) and MeHg(+) species. The separation of Hg(2+) and MeHg(+) was accomplished on a cation-exchange guard column using a glutathione (GSH)-containing eluent. To achieve optimal chromatographic separation and signal intensities, we investigated the influence of several of the operating parameters of the chromatographic and photocatalyst-assisted VG systems. Under the optimized conditions of VG process, the shortcomings of conventional SnCl(2)-based VG techniques for the vaporization of MeHg(+) was overcome; comparing to the concentric nebulizer-ICP-MS system, the analytical sensitivity of ICP-MS toward the detection of Hg(2+) and MeHg(+) were also improved to 25- and 7-fold, respectively. With the use of our established HPLC-UV/nano-TiO(2)-ICP-MS system, the precision for each analyte, based on three replicate injections of 2 ng/mL samples of each species, was better than 15% RSD. This hyphenated method also provided excellent detection limits--0.1 and 0.03 ng/mL for Hg(2+) and MeHg(+), respectively. A series of validation experiments--analysis of the NIST 2672a Standard Urine Reference Material and other urine samples--confirmed further that our proposed method could be applied satisfactorily to the determination of inorganic Hg(2+) and MeHg(+) species in real samples. PMID:19913233

  3. High-Throughput Analysis of Methylmalonic Acid in Serum, Plasma, and Urine by LC-MS/MS. Method for Analyzing Isomers Without Chromatographic Separation.

    PubMed

    Kushnir, Mark M; Nelson, Gordon J; Frank, Elizabeth L; Rockwood, Alan L

    2016-01-01

    Measurement of methylmalonic acid (MMA) plays an important role in the diagnosis of vitamin B12 deficiency. Vitamin B12 is an essential cofactor for the enzymatic carbon rearrangement of methylmalonyl-CoA (MMA-CoA) to succinyl-CoA (SA-CoA), and the lack of vitamin B12 leads to elevated concentrations of MMA. Presence of succinic acid (SA) complicates the analysis because mass spectra of MMA and SA are indistinguishable, when analyzed in negative ion mode and the peaks are difficult to resolve chromatographically. We developed a method for the selective analysis of MMA that exploits the significant difference in fragmentation patterns of di-butyl derivatives of the isomers MMA and SA in a tandem mass spectrometer when analyzed in positive ion mode. Tandem mass spectra of di-butyl derivatives of MMA and SA are very distinct; this allows selective analysis of MMA in the presence of SA. The instrumental analysis is performed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) in positive ion mode, which is, in combination with selective extraction of acidic compounds, is highly selective for organic acids with multiple carboxyl groups (dicarboxylic, tricarboxylic, etc.). In this method organic acids with a single carboxyl group are virtually undetectable in the mass spectrometer; the only organic acid, other than MMA, that is detected by this method is its isomer, SA. Quantitative measurement of MMA in this method is performed using a deconvolution algorithm, which mathematically resolves the signal corresponding to MMA and does not require chromatographic resolution of the MMA and SA peaks. Because of its high selectivity, the method utilizes isocratic chromatographic separation; reconditioning and re-equilibration of the chromatographic column between injections is unnecessary. The above features of the method allow high-throughput analysis of MMA with analysis cycle time of 1 min. PMID:26602128

  4. Relationship between chromatographic resolution and amide structure of chiral 2-hydroxy acids as O-(-)-menthoxycarbonylated diastereomeric derivatives for enantiomeric separation on achiral gas chromatography.

    PubMed

    Cha, Eunju; Kim, Sohee; Lee, Kang Mi; Kim, Ho Jun; Kim, Ki Hun; Kwon, Oh-Seung; Park, Ki Duk; Lee, Jaeick

    2016-02-15

    The relationship between chromatographic resolution and amide structure of chiral 2-hydroxy acids as O-(-)-menthoxycarbonylated diastereomeric derivatives on achiral gas chromatography was investigated to elucidate the best diastereomeric conformation for enantiomeric separation of chiral 2-hydroxy acids. Thirteen chiral 2-hydroxy acids were converted into nine different diastereomeric O-(-)-menthoxycarbonylated amide derivatives using the primary, secondary and cyclic amines to achieve complete enantiomeric separation through an achiral column. Each enantiomeric pair of 2-hydroxy acids as O-(-)-menthoxycarbonylated tert-butylamide derivatives was resolved on both the DB-5 and DB-17 columns with resolution factors ranging from 1.7 to 4.8 and 1.7 to 3.4, respectively. The results revealed that the structure of the amide moiety is shown to significantly affect chromatographic resolution. In addition, O-(-)-menthoxycarbonylated tert-butylamide derivatives were shown to be the best diastereomeric conformations for enantiomeric separation of 2-hydroxy acids. When comparing with our previous O-trifluoroacetylated(-)-menthyl ester derivatization method, the present results suggested that size differences between groups attached to the chiral center and conformational rigidity can have stronger effects on resolution than the distance between chiral centers. The elution of R- and S-stereoisomers was affected by the class of amine; i.e., primary, secondary, or cyclic, regardless of the substituents on the amine group, the structure of the 2-hydroxy acid, and the polarity of the column. PMID:26800225

  5. Modified normal-phase ion-pair chromatographic methods for the facile separation and purification of imidazolium-based ionic compounds

    SciTech Connect

    Urban, ND; Schenkel, MR; Robertson, LA; Noble, RD; Gin, DL

    2012-07-04

    lmidazolium- and oligo(imidazolium)-based ionic organic compounds are important in the design of room-temperature ionic liquid materials; however, the chromatographic analysis and separation of such compounds are often difficult. A convenient and inexpensive method for effective thin-layer chromatography (TLC) analysis and column chromatography separation of imidazolium-based ionic compounds is presented. Normal-phase ion-pair TLC is used to effectively analyze homologous mixtures of these ionic compounds. Subsequent separation of the mixtures is performed using ion-pair flash chromatography on normal-phase silica gel, yielding high levels of recovery. This method also results in a complete exchange of the counter anion on the imidazolium compounds to the anion of the ion-pair reagent. (C) 2012 Elsevier Ltd. All rights reserved.

  6. Polar Aprotic Modifiers for Chromatographic Separation and Back-Exchange Reduction for Protein Hydrogen/Deuterium Exchange Monitored by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Valeja, Santosh G.; Emmett, Mark R.; Marshall, Alan G.

    2012-04-01

    Hydrogen/deuterium exchange monitored by mass spectrometry is an important non-perturbing tool to study protein structure and protein-protein interactions. However, water in the reversed-phase liquid chromatography mobile phase leads to back-exchange of D for H during chromatographic separation of proteolytic peptides following H/D exchange, resulting in incorrect identification of fast-exchanging hydrogens as unexchanged hydrogens. Previously, fast high-performance liquid chromatography (HPLC) and supercritical fluid chromatography have been shown to decrease back-exchange. Here, we show that replacement of up to 40% of the water in the LC mobile phase by the modifiers, dimethylformamide (DMF) and N-methylpyrrolidone (NMP) (i.e., polar organic modifiers that lack rapid exchanging hydrogens), significantly reduces back-exchange. On-line LC micro-ESI FT-ICR MS resolves overlapped proteolytic peptide isotopic distributions, allowing for quantitative determination of the extent of back-exchange. The DMF modified solvent composition also improves chromatographic separation while reducing back-exchange relative to conventional solvent.

  7. Optimization by experimental design and artificial neural networks of the ion-interaction reversed-phase liquid chromatographic separation of twenty cosmetic preservatives.

    PubMed

    Marengo, E; Gianotti, V; Angioi, S; Gennaro, M C

    2004-03-12

    Particular attention are recently receiving antimicrobial agents added as preservatives in hygiene and cosmetics commercial products, since some of them are suspected to be harmful to the human health. The preservatives used belong to different classes of chemical species and are generally used in their mixtures. Multi-component methods able to simultaneously determinate species with different chemical structure are therefore highly required in quality control analysis. This paper presents an ion interaction RP-HPLC method for the simultaneous separation of the 20 typical antimicrobial agents most used in cosmetics and hygiene products, that are: benzoic acid, salicylic acid, 4-hydroxybenzoic acid, methyl-, ethyl-, propyl-, butyl-, benzyl-benzoate, methyl-, ethyl-, propyl-, butyl-, benzyl-paraben, o-phenyl-phenol, 4-chloro-m-cresol, triclocarban, dehydroacetic acid, bronopol, sodium pyrithione and chlorhexidine. For the development of the method and the optimization of the chromatographic conditions, an experimental design was planned and models were built by the use of artificial neural network to correlate the retention time of each analyte to the variables and their interactions. The neuronal models developed showed good predictive ability and were used, by a grid search algorithm, to optimize the chromatographic conditions for the separation of the mixture. PMID:15032350

  8. Gas chromatographic separation of bile acid 3-glucosides and 3-glucuronides without prior deconjugation on a stainless-steel capillary column.

    PubMed

    Iida, T; Tazawa, S; Tamaru, T; Goto, J; Nambara, T

    1995-01-01

    A method for the gas chromatographic (GC) separation of the 3-glucoside and 3-glucuronide conjugates of bile acids without the necessity for a hydrolytic step is described. The bile acid glycosides were derivatized to their complete methyl ester trimethylsilyl (Me-TMS) or methyl ester dimethylethylsilyl (Me-DMES) ether derivatives, which in turn were chromatographed on an inert and thermostable stainless-steel capillary column, Ultra ALLOY-1 (HT), coated with a thin film (0.15 micron) of chemically bonded and cross-linked dimethylsiloxane. They exhibited a single peak of the theoretical shape without any accompanying peaks due to thermal decomposition, even at oven temperatures of 320-330 degrees C. Excellent GC separation of isomeric bile acid glycosides was achieved by the combined use of suitable derivatives and column. This method, which does not need the prior deconjugation of the glycosidic moiety, could be usefully applied to biosynthetic and metabolic studies of bile acids in biological materials. PMID:7881536

  9. Fouling propensity and separation efficiency of epoxidated polyethersulfone incorporated cellulose acetate ultrafiltration membrane in the retention of proteins

    NASA Astrophysics Data System (ADS)

    Jayalakshmi, A.; Rajesh, S.; Mohan, D.

    2012-10-01

    Epoxidated polyethersulfone (EPES) incorporated cellulose acetate (CA) ultrafiltration membranes were prepared by diffusion induced precipitation technique in the absence and presence of pore former polyethyleneglycol-600. Effect of blend ratio on the compatibility, thermal stability, mechanical strength, hydrophilicity, morphology, pure water flux, protein adsorption resistance, protein separation efficiency and fouling propensity of the CA/EPES blend membranes was evaluated. Addition of EPES results in the formation of thin separating layer and spongy sub layer in CA/EPES blend membranes. The efficiency of these membranes in the separation of commercially important proteins such as bovine serum albumin, egg albumin, pepsin and trypsin was studied and found to be enhanced as compared to CA membranes. The fouling-resistant capability of the membranes was studied by bovine serum albumin as the model foulant and flux recovery ratio of the membranes were calculated. Attempts have been made to correlate the changes in membrane morphology with pure water flux, hydraulic resistance, thermal and mechanical stability, separation efficiency and antifouling property of the CA/EPES membranes. The optimal combination of CA and EPES, thus allows the preparation of high performance UF membranes which are sufficiently dense to retain proteins and at the same time give economically viable fluxes.

  10. Separation of macromolecular proteins and removal of humic acid by cellulose acetate modified UF membranes.

    PubMed

    Kanagaraj, P; Nagendran, A; Rana, D; Matsuura, T

    2016-08-01

    Surface modifying macromolecules (SMMs) were synthesized with various polyurethane pre polymers end-capped with different groups and blended into the casting solution of cellulose acetate (CA) to prepare surface modified ultra-filtration (UF) membranes for water filtration applications. The surface modification of the CA membranes was confirmed by the FTIR and static contact angle (SCA) measurements. The membranes so prepared had the typical characteristics of UF membranes as confirmed by scanning electron microscopy (SEM). Membrane properties were studied in terms of membrane compaction, percentage water content (%WC), pure water flux (PWF), membrane hydraulic resistance (Rm), molecular weight cut-off (MWCO), average pore size and porosity. The result showed that PWF, %WC, MWCO and pore size increased whereas the Rm decreased by the addition of SMMs. The significant effect of SMMs on the fouling by humic acid (HA) was also observed. It was found that the cSMM-3 membrane, in which SMM was synthesized with diethylene glycol (DEG) and hydroxyl benzene sulfonate (HBS) was blended, had the highest flux recovery ratio FRR (84.6%), as well as the lowest irreversible fouling (15.4%), confirming their improved antifouling properties. Thus, the SMM modified CA membranes had proven, to play an important role in the water treatment by UF. PMID:27118046

  11. Development of Low Cost Membranes (Ta, Nb & Cellulose Acetate) for H2/CO2 Separation in WGS Reactors

    SciTech Connect

    Seetala, Naidu; Siriwardane, Upali

    2011-12-15

    The main aim of this work is to synthesize low temperature bimetallic nanocatalysts for Water Gas Shift reaction (WGS) for hydrogen production from CO and steam mixture; and develop low-cost metal (Nb/Ta)/ceramic membranes for H2 separation and Cellulose Acetate membranes for CO2 separation. .

  12. Evaluation and application of a mixed-mode chromatographic stationary phase in two-dimensional liquid chromatography for the separation of traditional Chinese medicine.

    PubMed

    Wei, Zhishen; Fu, Qing; Cai, Jianfeng; Huan, Liyun; Zhao, Jianchao; Shi, Hui; Jin, Yu; Liang, Xinmiao

    2016-06-01

    In this study, two mixed-mode chromatography stationary phases (C8SAX and C8SCX) were evaluated and used to establish a two-dimensional liquid chromatography system for the separation of traditional Chinese medicine. The chromatographic properties of the mixed-mode columns were systematically evaluated by comparing with other three columns of C8, strong anion exchanger, and strong cation exchanger. The result showed that C8SAX and C8SCX had a mixed-mode retention mechanism including electrostatic interaction and hydrophobic interaction. Especially, they were suitable for separating acidic and/or basic compounds and their separation selectivities could be easily adjusted by changing pH value. Then, several off-line 2D-LC systems based on the C8SAX in the first dimension and C8SAX, C8SCX, or C8 columns in the second dimension were developed to analyze a traditional Chinese medicine-Uncaria rhynchophylla. The two-dimensional liquid chromatography system of C8SAX (pH 3.0) × C8SAX (pH 6.0) exhibited the most effective peak distribution. Finally, fractions of U. rhynchophylla prepared from the first dimension were successfully separated on the C8SAX column with a gradient pH. Thus, the mixed-mode stationary phase could provide a platform to separate the traditional Chinese medicine in practical applications. PMID:27159545

  13. THORIUM OXALATE-URANYL ACETATE COUPLED PROCEDURE FOR THE SEPARATION OF RADIOACTIVE MATERIALS

    DOEpatents

    Gofman, J.W.

    1959-08-11

    The recovery of fission products from neutronirradiated uranium is described. The neutron-irradiated uranium is dissolved in acid and thorium oxalate is precipitated in ihe solution formed, whereby the fission products are carried on the thorium oxalate. The separated thorium oxalate precipitate is then dissolved in an aqueous oxalate solution and the solution formed is acidified, limiting ihe excess acidity to a maximum of 2 N, whereby thorium oxalate precipitates and carries lanthanum-rareearth- and alkaline-earth-metal fission products while the zirconium-fission-product remains in solution. This precipitate, too, is dissolved in an aqaeous oxalate solution at elevated temperature, and lanthanum-rare-earth ions are added to the solution whereby lanthanum-rare-earth oxalate forms and the lanthanum-rare-earth-type and alkalineearth-metal-type fission products are carried on the oxalate. The precipitate is separated from the solution.

  14. Chromatographic enrichment and subsequent separation of nickel and vanadyl porphyrins from natural seeps and molecular characterization by positive electrospray ionization FT-ICR mass spectrometry.

    PubMed

    Putman, Jonathan C; Rowland, Steven M; Corilo, Yuri E; McKenna, Amy M

    2014-11-01

    We report a novel chromatographic method to enrich and separate nickel and vanadyl porphyrins from a natural seep sample and combine molecular level characterization by positive-ion electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS). Vanadyl and nickel porphyrin model compound elution from primary secondary amine (PSA) stationary phase combined with UV-vis spectroscopy confirms enrichment and subsequent fractionation of nickel and vanadyl porphyrins into polarity-based subfractions. A more than 100-fold increase in signal-to-noise ratio for nickel porphyrins enables unequivocal elemental composition assignment confirmed by isotopic fine structure for all isotopes >1% relative abundance, and the first mass spectral identification of (61)Ni porphyrin isotopologues derived from natural seeps. Oxygen-containing vanadyl porphyrins and sulfur-containing vanadyl porphyrins are isolated in the same fraction simultaneously from the same sample. We provide the first chromatographic evidence of carboxylic acid functionalities peripheral to the porphyrin core, in agreement with previous studies. PMID:25286139

  15. Separation of carrier-free {sup 90}Y from high level waste by extraction chromatographic technique using 2-ethylhexyl-2-ethylhexyl phosphonic acid (KSM-17)

    SciTech Connect

    Achuthan, P.V.; Dhami, P.S.; Kannan, R.; Gopalakrishnan, V.; Ramanujam, A.

    2000-01-01

    An extraction chromatographic technique has been developed for the separation of carrier-free {sup 90}Y from the {sup 90}Sr present in the high level waste (HLW) of the Purex process. When a Purex HLW solution in 2--3 M HNO{sub 3} is passed through a CMPO-Chromosorb-102 (CAC) column, all the trivalent, tetravalent, and hexavalent ions are sorbed. The effluent from this experiment, after adjusting the pH to 2 with NaOH, was passed through a 2-ethylhexyl-2-ethylhexyl phosphonic acid (KSM-17)-Chromosorb-102 (KSMC) extraction chromatographic column where only {sup 90}Y was sorbed. All the other ions ({sup 90}Sr, {sup 137}Cs, {sup 125}Sb, {sup 106}Ru, {sup 106}Rh, etc.) were washed off with dilute HNO{sub 3} (pH 2), and carrier-free {sup 90}Y was eluted with 0.5 M HNO{sub 3}. This technique can yield {sup 90}Y in mCi levels in pure form for medical applications. The {sup 90}Sr can be used repeatedly after allowing for {sup 90}Y buildup.

  16. Synthesis and characterization of novel stationary phases for small scale liquid chromatographic separations of proteins and nanoparticles

    NASA Astrophysics Data System (ADS)

    Hutanu, Daniela

    The emerging field of nanotechnology strictly requires the micro-scaling of the available separation technology and the design of novel devices for separations of molecules of interest. The separation of proteins and nanoparticles is challenging due to their relatively large size, non-specific adherence to surfaces and instability in many solvents. This dissertation presents the synthesis and characterization of novel stationary phases for use in separations of proteins or nanoparticles in both capillary and microchip formats. In order to separate blood proteins with high specificity, a DNA aptamer selected for alpha-thrombin was employed as an affinity component of the stationary phases. Silica surfaces and organic monoliths were modified with the aptamer via an azlactone linkage and have demonstrated highly efficient separations of thrombin from a mixture in the microscale. The high efficiency of the protein separation (HETP = 276 mum, RS = 1.7) is comparable with macroscale results using antibodies as the affinity factor. Novel hybrid inorganic-organic polysilsesquioxane stationary phases were synthesized by way of surfactant templated polymerization of bridged alcoxy-silyl ethane monomers, in presence of sodium hydroxide. The novel materials were successful in size exclusion separation of polystyrene standards with molecular diameters of 0.3-2.4 nm. A hybrid inorganic-organic polysilsesquioxane sorbent also proved useful for small scale separations of triphenyl phosphine protected gold nanoparticles, based on a sorptive mechanism instead of a size exclusion mechanism. Polysilsesquioxanes were easily synthesized in-situ inside fused silica capillary columns and PMMA microchip channels in order to facilitate integration with a micro-reactor. The novel stationary phases proved efficient for separation of proteins and nanoparticles in the micro-scale format and can further be utilized for online purification and separation of these difficult compounds.

  17. An affinity-based strategy for the design of selective displacers for the chromatographic separation of proteins.

    PubMed

    Vutukuru, Srinavya; Kate, Sandesh D; McCallum, Scott A; Morrison, Christopher J; Cramer, Steven M; Kane, Ravi S

    2008-06-01

    We describe an affinity-based strategy for designing selective protein displacers for the chromatographic purification of proteins. To design a displacer that is selective for a target protein, we attached a component with affinity for the target protein to a resin-binding component; we then tested the ability of such displacers to selectively retain the target protein on a resin relative to another protein having a similar retention time. In particular, we synthesized displacers based on biotin, which selectively retained avidin as compared to aprotinin on SP Sepharose high performance resin. In addition, we have extended this approach to develop an affinity-peptide-based displacer that discriminates between lysozyme and cytochrome c. Here, a selective displacer was designed from a lysozyme-binding peptide that had been identified and optimized previously using phage-display technology. Our results suggest a general strategy for designing highly selective affinity-based displacers by identifying molecules (e.g., peptides) that bind to a protein of interest and using an appropriate linker to attach these molecules to a moiety that binds to the stationary phase. PMID:18512879

  18. Gas chromatographic separation of stereoisomers of non-protein amino acids on modified γ-cyclodextrin stationary phase.

    PubMed

    Fox, Stefan; Strasdeit, Henry; Haasmann, Stephan; Brückner, Hans

    2015-09-11

    Stereoisomers (enantiomers and diastereoisomers) of synthetic, non-protein amino acids comprising α-, β-, and γ-amino acids, including α,α-dialkyl amino acids, were converted into the respective N-trifluoroacetyl-O-methyl esters and analyzed and resolved by gas chromatography (GC) on a commercial fused silica capillary column coated with the chiral stationary phase octakis(3-O-butyryl-2,6-di-O-pentyl)-γ-cyclodextrin. This column is marketed under the trade name Lipodex(®) E. Chromatograms, retention times, and a chart displaying the retention times of approximately 40 stereoisomers of amino acids are presented. With few exceptions, baseline or almost baseline resolution was achieved for enantiomers and diastereoisomers. The chromatographic method presented is considered to be highly suitable for the elucidation of the stereochemistry of non-protein amino acids, for example in natural products, and for evaluating the enantiopurity of genetically non-coded amino acids used for the synthesis and design of conformationally tailored peptides. The method is applicable to extraterrestrial materials or can be used in experimental work related to abiotic syntheses or enantioselective destruction and amplification of amino acids. PMID:26278360

  19. Chromatographic NMR in NMR solvents

    NASA Astrophysics Data System (ADS)

    Carrara, Caroline; Viel, Stéphane; Delaurent, Corinne; Ziarelli, Fabio; Excoffier, Grégory; Caldarelli, Stefano

    2008-10-01

    Recently, it was demonstrated that pseudo-chromatographic NMR experiments could be performed using typical chromatographic solids and solvents. This first setup yielded improved separation of the spectral components of the NMR spectra of mixtures using PFG self-diffusion measurements. The method (dubbed Chromatographic NMR) was successively shown to possess, in favorable cases, superior resolving power on non-functionalized silica, compared to its LC counterpart. To further investigate the applicability of the method, we studied here the feasibility of Chromatographic NMR in common deuterated solvents. Two examples are provided, using deuterated chloroform and water, for homologous compounds soluble in these solvents, namely aromatic molecules and alcohols, respectively.

  20. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    PubMed

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous. PMID:26614172

  1. Fabrication of zeolitic imidazolate framework-8-methacrylate monolith composite capillary columns for fast gas chromatographic separation of small molecules.

    PubMed

    Yusuf, Kareem; Badjah-Hadj-Ahmed, Ahmed Yacine; Aqel, Ahmad; ALOthman, Zeid Abdullah

    2015-08-01

    A composite zeolitic imidazolate framework-8 (ZIF-8) with a butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.) was fabricated to enhance the separation efficiency of methacrylate monoliths toward small molecules using conventional low-pressure gas chromatography in comparison with a neat butyl methacrylate-co-ethylene dimethacrylate (BuMA-co-EDMA) monolithic capillary column (33.5cm long×250μm i.d.). The addition of 10mgmL(-1) ZIF-8 micro-particles increased the BET surface area of BuMA-co-EDMA by 3.4-fold. A fast separation of five linear alkanes in 36s with high resolution (Rs≥1.3) was performed using temperature program. Isothermal separation of the same sample also showed a high efficiency (3315platesm(-1) for octane) at 0.89min. Moreover, the column was able to separate skeletal isomers, such as iso-octane/octane and 2-methyl octane/nonane. In addition, an iso-butane/iso-butylene gas mixture was separated at ambient temperature. Comparison with an open tubular TR-5MS column (30m long×250μm i.d.) revealed the superiority of the composite column in separating the five-membered linear alkane mixture with 4-5 times increase in efficiency and a total separation time of 0.89min instead of 4.67min. A paint thinner sample was fully separated using the composite column in 2.43min with a good resolution (Rs≥0.89). The perfect combination between the polymeric monolith, with its high permeability, and ZIF-8, with its high surface area and flexible 0.34nm pore openings, led to the fast separation of small molecules with high efficiency and opened a new horizon in GC applications. PMID:26141277

  2. Gas chromatographic separation of nitrogen, oxygen, argon, and carbon monoxide using custom-made porous polymers from high purity divinylbenzene

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.; Ohara, D.; Hollis, O. L.

    1984-01-01

    Existing porous polymers were surveyed for their ability to separate the subject gases. Certain products that showed more promise than others were synthesized and the existing synthetic procedures studied and modified to produce new polymers with enhanced ability to separate the subject gases. Evaluation of the porous polymers was carried out practically by gas chromatography at ambient temperature. The modified synthetic procedures were somewhat simpler than the originals. The new porous polymers made with high purity divinylbenzene enabled use of shorter columns to obtain the separations desired.

  3. Preparation of monodispersed vinylpyridine-divinylbenzene porous copolymer resins and their application to high-performance liquid chromatographic separation of aromatic amines.

    PubMed

    Kitahara, Kei-Ichi; Okuya, Shuji; Yoshihama, Isao; Hanada, Takako; Nagashima, Kunio; Arai, Sadao

    2009-10-30

    For the separation of aromatic amines, two types of monodispersed porous polymer resins were prepared by the copolymerization of 2-vinylpyridine and 4-vinylpyridine with divinylbenzene in the presence of template silica gel particles (particle size 5 microm), followed by dissolution of the template silica gel in an alkaline solution. The transmission electron micrographs and the scanning electron micrograph revealed that these templated polymer resins have a spherical morphology with a good monodispersity and porous structure. Using these monodispersed polymer resins, the high-performance liquid chromatographic separation of aromatic amines in the mobile phases of pHs 2.0, 2.9, 4.1, 7.2 and 11.7 were carried out. The 2-vinylpyridine-divinylbenzene copolymer resins showed slightly stronger retentions for aromatic amines than the 4-vinylpyridine-divinylbenzene copolymer resins. Under acidic conditions (around pH 2.0), aniline and the toluidines showed no retention on these copolymer resins due to the repulsion between the cationic forms of these amines and pyridinium cations in the stationary phase, whereas less basic aromatic amines or non-basic acetanilide showed slight retentions. Above pH 4.1, the separation of aromatic amines with these polymer resins showed a typical reversed-phase mode separation. Therefore, the separation patterns of aromatic amines are effectively tunable by changing the pH value of the mobile phases. A good separation of eight aromatic amines was achieved at pH 2.9 using the 2-vinylpyridine-divinylbenzene copolymer resins. PMID:19442983

  4. Molecular recognition principles and stationary-phase characteristics of topoisomer-selective chemoaffinity materials for chromatographic separation of circular plasmid DNA topoisomers.

    PubMed

    Mahut, Marek; Lindner, Wolfgang; Lämmerhofer, Michael

    2012-01-18

    We recently discovered the molecular recognition capability of a quinine carbamate ligand attached to silica as a powerful chemoaffinity material for the chromatographic separation of circular plasmid topoisomers of different linking numbers. In this paper we develop structure-selectivity relationship studies to figure out the essential structural features for topoisomer recognition. By varying different moieties of the original cinchonan-derived selector, it was shown that intercalation by the quinoline moiety of the ligand as assumed initially as the working hypothesis is not an essential feature for topoisomer recognition during chromatography. We found that the key elements for topoisomer selectivity are the presence of a rigid weak anion-exchange site and a H-donor site separated from each other in a defined distance by a 4-atom spacer. Additionally, incorporation of the weak anion-exchange site into a cyclic ring structure provides greater rigidity of the ligand molecule and turned out to be advantageous, if not mandatory, for (close to) baseline separation. PMID:22191385

  5. Chromatographic comparison of atenolol separation in reaction media on cellulose tris-(3,5-dimethylphenylcarbamate) chiral stationary phase using ultra fast liquid chromatography.

    PubMed

    Agustian, Joni; Kamaruddin, Azlina Harun; Aboul-Enein, Hassan Y

    2012-05-01

    Because chiral liquid chromatography (LC) could become a powerful tool to estimate racemic atenolol quantity, excellent enantiomeric separation should be produced during data acquisition for satisfactory observation of atenolol concentrations throughout the racemic resolution processes. Selection of chiral LC column and analytical protocol that fulfill demands of the ultra fast LC analysis is essential. This article describes the characteristics of atenolol chromatographic separation that resulted from different resolution media and analytical protocols with the use of a Chiralcel® OD column. The chromatograms showed quite different characteristics of the separation process. The single enantiomer and racemic atenolol could be recognized by the Chiralcel® OD column in less than 20 min. Symmetrical peaks were obtained; however, several protocols produced peaks with wide bases and slanted baselines. Observations showed that efficient enantioresolution of racemic atenolol was obtained at slow mobile phase flow rate, decreased concentration of amine-type modifier but increased alcohol content in mobile phase and highest ultraviolet detection wavelength were required. The optimal ultra fast LC protocol enables to reduce and eliminate the peaks of either the atenolol solvent or the buffers and provided the highest peak intensities of both atenolol enantiomers. PMID:22517322

  6. Derivative Quotient Spectrophotometry and an Eco-Friendly Micellar Chromatographic Approach with Time-Programmed UV-Detection for the Separation of Two Fluoroquinolones and Phenazopyridine.

    PubMed

    Tolba, Manar M; Salim, Mohamed M

    2016-05-01

    In this study, two analytical approaches were exploited for the resolution of binary mixtures of ciprofloxacin HCl (CIP) or norfloxacin (NOR) and phenazopyridine HCl (PHZ). In the first approach, the amplitudes of the first derivative of the ratio spectra were measured at 267 or 287 nm for CIP and at 268 or 291 nm for NOR. PHZ could be directly determined in the presence of CIP or NOR at 405 nm. The calibration graphs were rectilinear over the ranges of 1.0-16.0 µg/mL for CIP or NOR and 1.0-10.0 µg/mL for PHZ. In the second approach, an accurate, reliable and environmentally nontoxic micellar liquid chromatographic (MLC) method was developed. A good chromatographic separation was achieved using a 150 mm × 4.6 mm i.d., 5 µm particle size Spherisorb ODS-2 column. Eco-friendly mobile phase containing 0.12 M sodium dodecyl sulphate, 0.3% triethylamine and 6%n-butanol in 0.02 M orthophosphoric acid of pH 3.0 was pumped at a flow rate of 1 mL/min. Time programmed UV-detection was applied to allow sensitive determination of the studied drugs. The analytes were eluted without interferences in <10 min. Methocarbamol was used as an internal standard. The MLC method was found to be rectilinear over the concentration range of 0.5-20.0 μg/mL for CIP, NOR or PHZ. These optimized and validated methods were successfully applied for the simultaneous analysis of the studied drugs in their synthetic mixtures and co-formulated tablets. Moreover, the second method was further extended to the determination of these drugs in human urine with direct injection and without any pretreatment. PMID:26867555

  7. Liquid chromatographic separation of pregabalin and its possible impurities with fluorescence detection after postcolumn derivatization with o-phtaldialdehyde.

    PubMed

    Dousa, Michal; Gibala, Petr; Lemr, K

    2010-11-01

    A rapid procedure based on direct extraction and RP-HPLC separation of pregabalin and its possible impurities with fluorescence detection has been developed. The separation conditions and parameters of derivatization reaction for postcolumn derivatization of pregabalin with o-phtaldialdehyde/2-mercaptoethanol were studied. Purospher STAR RP-8e column with isocratic elution was employed. Fluorescence detection was performed at excitation and emission wavelength of 345 nm and 450 nm, respectively. The proposed method has an advantage of a simple sample pre-treatment and a quick and very sensitive HPLC method. The applicability of developed method was successfully verified during analysis of commercial samples of tablets of Lyrica (Pfizer, USA). PMID:20435423

  8. Evaluation of mixed-mode chromatographic resins for separating IgG from serum albumin containing feedstock.

    PubMed

    Wang, Rong-Zhu; Lin, Dong-Qiang; Tong, Hong-Fei; Lu, Hui-Li; Yao, Shan-Jing

    2013-10-01

    Mixed-mode chromatography has been focused as a cost-effective new technique for antibody purification. In this study, four mixed-mode resins with N-benzyl-N-methyl ethanol amine, 2-benzamido-4-mercaptobutanoic acide, 4-mercapto-ethyl-pyridine and phenylpropylamine as the ligands were tested and the multi-functional interactions between ligand and protein were discussed. Immunoglobulin G (IgG), bovine serum albumin (BSA) and the binary mixture of BSA and IgG were used as the model feedstock to compare the separation behaviors by pH gradient elution. The comparison analysis showed mixed-mode resin with N-benzyl-N-methyl ethanol amine as the ligand had the best ability to separate IgG and BSA. The results indicated that for four resins tested ionic interaction might play the dominant role in the separation of IgG and BSA while the hydrophobic interactions and hydrogen bonding have some subsidiary effects. The pH stepwise elution and sample loading were optimized to improve the IgG purification from serum albumin containing feedstock. High purity (92.3%) and high recovery (95.6%) of IgG were obtained. The results indicated that mixed-mode chromatography would be a potential option for antibody purification with the control of loading and elution conditions. PMID:23973532

  9. A gas chromatograph/mass spectrometry method for determining isotopic distributions in organic compounds used in the chemical approach to stable isotope separation

    SciTech Connect

    Martinez, A.M.; Spall, W.D.; Smith, B.F.

    1990-01-01

    A variety of gas chromatograph/mass spectrometry (GC/MS) methods have been developed to resolve benzene, benzophenone, anthracene, fluorenone, and their respective stable isotope analogs from other components by gas chromatography. The ratio of stable isotope-labeled material to natural isotopic abundance compounds is determined from the mass spectra averaged across the chromatographic peak. Both total ion and selective ion chromatographic approaches were used for relative data and comparison. 9 refs., 11 tabs.

  10. Combined cation-exchange and extraction chromatographic method of pre-concentration and concomitant separation of Cu(II) with high molecular mass liquid cation exchanger after its online detection.

    PubMed

    Mandal, B; Roy, U S; Datta, D; Ghosh, N

    2011-08-19

    A selective method has been developed for the extraction chromatographic trace level separation of Cu(II) with Versatic 10 (liquid cation exchanger) coated on silanised silica gel (SSG-V10). Cu(II) has been extracted from 0.1M acetate buffer at the range of pH 4.0-5.5. The effects of foreign ions, pH, flow-rate, stripping agents on extraction and elution have been investigated. Exchange capacity of the prepared exchanger at different temperatures with respect to Cu(II) has been determined. The extraction equilibrium constant (K(ex)) and different standard thermodynamic parameters have also been calculated by temperature variation method. Positive value of ΔH (7.98 kJ mol⁻¹) and ΔS (0.1916 kJ mol⁻¹) and negative value of ΔG (-49.16 kJ mol⁻¹) indicated that the process was endothermic, entropy gaining and spontaneous. Preconcentration factor was optimized at 74.7 ± 0.2 and the desorption constants K(desorption)¹(1.4 × 10⁻²) and K(desorption)²(9.8 × 10⁻²) were determined. The effect of pH on R(f) values in ion exchange paper chromatography has been investigated. In order to investigate the sorption isotherm, two equilibrium models, the Freundlich and Langmuir isotherms, were analyzed. Cu(II) has been separated from synthetic binary and multi-component mixtures containing various metal ions associated with it in ores and alloy samples. The method effectively permits sequential separation of Cu(II) from synthetic quaternary mixture containing its congeners Bi(III), Sn(II), Hg(II) and Cu(II), Cd(II), Pb(II) of same analytical group. The method was found effective for the selective detection, removal and recovery of Cu(II) from industrial waste and standard alloy samples following its preconcentration on the column. A plausible mechanism for the extraction of Cu(II) has been suggested. PMID:21764063

  11. Immobilized β-cyclodextrin-based silica vs polymer monoliths for chiral nano liquid chromatographic separation of racemates.

    PubMed

    Ghanem, Ashraf; Ahmed, Marwa; Ishii, Hideaki; Ikegami, Tohru

    2015-01-01

    The enantioselectivity of immobilized β-cyclodextrin phenyl carbamate-based silica monolithic capillary columns was compared to our previously described polymer counterpart. 2,3,6-Tris(phenylcarbamoyl)-β-cyclodextrin-6-methacrylate was used as a functional monomer for the preparation of β-cyclodextrin (β-CD)-based silica and polymer monoliths. The silica monoliths were prepared via the sol-gel technique in fused silica capillary followed by modification of the bare silica monoliths with an anchor group prior to polymerization with β-CD methacrylate using either 2,2'-azobis(isobutyronitrile) or benzoylperoxide as radical initiators. On the other hand, the polymer monoliths were prepared via the copolymerization of β-CD methacrylate and ethylene glycol dimethacrylate in different ratios in situ in fused silica capillary. The prepared silica/polymer monoliths were investigated for the chiral separation of different classes of pharmaceuticals namely; α- and β-blockers, anti-inflammatory drugs, antifungal drugs, dopamine antagonists, norepinephrine-dopamine reuptake inhibitors, catecholamines, sedative hypnotics, diuretics, antihistaminics, anticancer drugs and antiarrhythmic drugs. Baseline separation was achieved for alprenolol, bufuralol, carbuterol, cizolertine, desmethylcizolertine, eticlopride, ifosfamide, 1-indanol, propranolol, tebuconazole, tertatolol and o-methoxymandelic acid under reversed phase conditions using mobile phase composed of methanol and water. The silica-based monoliths showed a comparative enantioselectivity to the polymer monoliths. PMID:25476312

  12. E.S.R. of spin-trapped radicals in gamma-irradiated polycrystalline amino acids. Chromatographic separation of radicals.

    PubMed

    Makino, K; Riesz, P

    1982-06-01

    The free radicals produced by gamma-radiolysis of polycrystalline amino acids (L-valine, L-leucine, L-isoleucine and L-proline) at room temperature in the absence of air were investigated by spin trapping with 2-methyl-2-nitrosopropane (MNP). The spin adducts produced by dissolving the irradiated solids in aqueous MNP solutions were separated by high-performance liquid chromatography and then identified by e.s.r. Deamination (ring-opening reaction for L-proline) was observed for all amino acid. For L-valine and L-leucine, H-abstraction from the tertiary carbon in the side chains occurred. For isoleucine, H-abstractions from the alpha-carbon of the amino acid and from a non-terminal carbon in the side chain were found. PMID:6288602

  13. Versatile gas/particle ion chromatograph.

    PubMed

    Ullah, S M Rahmat; Takeuchi, Masaki; Dasgupta, Purnendu K

    2006-02-01

    A new, compact gas/particle ion chromatograph has been developed for measuring ionic constituents in PM2.5 (particulate matter of aerodynamic diameter < or = 2.5 microm) and water-soluble ionogenic gases. The instrument has separate sampling channels for gases and particles. In one, a membrane denuder collects soluble gases for preconcentration and analysis. In the other, a cyclone removes larger particles, a membrane denuder removes soluble gases, and a continuously wetted hydrophilic filter collects particles. A single, multiport, syringe pump handles liquid transport, and one conductivity detector measures anions and ammonium for both channels. Electrodialytically generated gradient hydroxide eluent permits 20 min chromatographic runs. Gas/particle samples are each collected for 40 min, butthe sampling intervals are staggered by 20 min. Liquid samples from the gas denuder and particle collector are aspirated and preconcentrated on sequential cation and anion concentrators and transferred respectively to an ammonia transfer device and an anion separation column. The flow configuration results in an ammonium peak before anion peaks in the chromatogram. The system measures ammonia, organic acids (such as acetic, formic, and oxalic acids), HCl, HONO, SO2, HNO3, and the corresponding ions in the aerosol phase. Low ng/m3 to sub-ng/m3 limits of detection (LODs) are attained for most common gases and particulate constituents, the LODs for gaseous SO2 to NH3 range, for example, from sub parts per trillion by volume (sub-pptv) to approximately 5 pptv. PMID:16509343

  14. Differential chemical derivatization integrated with chromatographic separation for analysis of isomeric sialylated N-glycans: a nano-hydrophilic interaction liquid chromatography-MS platform.

    PubMed

    Tousi, Fateme; Bones, Jonathan; Hancock, William S; Hincapie, Marina

    2013-09-01

    MS analysis of sialylated glycans is challenging due to their low ionization efficiency in positive ion mode as well as the possibility of in-source fragmentation. Chemical derivatization strategies have been developed to address this issue focused on removal of the labile acidic proton prior to MS analysis. Highly sialylated negatively charged glycans also exhibit high retention and unsatisfactory separation efficiency when analyzed by hydrophilic interaction liquid chromatography (HILIC) due to their high polarity. Here, we combined linkage specific derivatization of sialic acids by reaction with the condensation reagent 4-(4,6-dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride (DMT-MM) in methanol with nanoscale liquid chromatographic separation prior to accurate mass Orbitrap MS analysis. Coupling DMT-MM charge neutralization of sialic acids with nano-HILIC-Orbitrap-MS not only allows for linkage specific characterization of sialylated glycans directly from the precursor mass but also improves the preceding HILIC separation by increasing the hydrophobicity and altering the selectivity of the oligosaccharide analytes. We focused on the trisialylated N-glycan fraction from haptoglobin and human plasma, enriched using weak anion exchange chromatography, as this trisialylated fraction has been linked with cancer associated changes in the serum N-glycome. The developed methodology was applied to investigate whether structural alterations in this oligosaccharide pool, enriched from the sera of pathological stage and sex matched patients bearing lung, breast, ovarian, pancreatic, or gastric cancer, demonstrate any degree of cancer specificity or whether changes in expression levels are purely cancer associated. The results of this pilot study indicate limited degrees of cancer specificity, particularly for pancreatic cancer, based on alterations in the relative abundance of specific trisialylated isomers. PMID:23901877

  15. Supercritical fluid carbon dioxide extraction and liquid chromatographic separation with electrochemical detection of methylmercury from biological samples

    USGS Publications Warehouse

    Simon, N.S.

    1997-01-01

    Using the coupled methods presented in this paper, methylmercury can be accurately and rapidly extracted from biological samples by modified supercritical fluid carbon dioxide and quantitated using liquid chromatography with reductive electrochemical detection. Supercritical fluid carbon dioxide modified with methanol effectively extracts underivatized methylmercury from certified reference materials Dorm-1 (dogfish muscle) and Dolt-2 (dogfish liver). Calcium chloride and water, with a ratio of 5:2 (by weight), provide the acid environment required for extracting methylmercury from sample matrices. Methylmercury chloride is separated from other organomercury chloride compounds using HPLC. The acidic eluent, containing 0.06 mol L-1 NaCl, insures the presence of methylmercury chloride and facilitates the reduction of mercury on a glassy carbon electrode. If dual glassy carbon electrodes are used, a positive peak is observed at -0.65 to -0.70 V and a negative peak is observed at -0.90V with the organomercury compounds that were tested. The practical detection limit for methylmercury is 5 X 10-8 mol L-1 (1 X 10-12 tool injected) when a 20 ??L injection loop is used.

  16. Determination of methyl mercury by aqueous phase Eehylation, followed by gas chromatographic separation with cold vapor atomic fluorescence detection

    USGS Publications Warehouse

    De Wild, John F.; Olsen, Mark L.; Olund, Shane D.

    2002-01-01

    A recent national sampling of streams in the United States revealed low methyl mercury concentrations in surface waters. The resulting median and mean concentrations, calculated from 104 samples, were 0.06 nanograms per liter (ng/L) and 0.15 ng/L, respectively. This level of methyl mercury in surface water in the United States has created a need for analytical techniques capable of detecting sub-nanogram per liter concentrations. In an attempt to create a U.S. Geological Survey approved method, the Wisconsin District Mercury Laboratory has adapted a distillation/ethylation/ gas-phase separation method with cold vapor atomic fluorescence spectroscopy detection for the determination of methyl mercury in filtered and unfiltered waters. This method is described in this report. Based on multiple analyses of surface water and ground-water samples, a method detection limit of 0.04 ng/L was established. Precision and accuracy were evaluated for the method using both spiked and unspiked ground-water and surface-water samples. The percent relative standard deviations ranged from 10.2 to 15.6 for all analyses at all concentrations. Average recoveries obtained for the spiked matrices ranged from 88.8 to 117 percent. The precision and accuracy ranges are within the acceptable method-performance limits. Considering the demonstrated detection limit, precision, and accuracy, the method is an effective means to quantify methyl mercury in waters at or below environmentally relevant concentrations

  17. Simultaneous separation and sensitive detection of naringin and naringenin in nanoparticles by chromatographic method indicating stability and photodegradation kinetics.

    PubMed

    Cordenonsi, Leticia Malgarim; Bromberger, Nathany Genro; Raffin, Renata Platcheck; Scherman, Elfrides Eva

    2016-02-01

    A simple, sensitive, precise and linear method by liquid chromatography was established for simultaneous determination and quantification of naringin and naringenin in polymeric nanoparticles. The method results in excellent separation in <11 min and with a peak purity of both flavonoids. The analyses were performed using a C18 column (4.6 × 150 mm, 5 µm), at a 1 mL/min flow rate. The mobile phase consisted of a gradient of acetonitrile-water (pH 4.0; v/v) at a temperature of 25°C. The nanoparticles were prepared according to the method of interfacial deposition of a pre-formed polymer. The method were validated in compliance with guidelines, and was found to be linear in the 1-40 µg/mL concentration range for both naringin and naringenin (r > 0.99). Repeatability was determined at three concentration levels, obtaining an RSD (%) <0.9%, and the accuracy of the method was >98%. The photodegradation kinetics was determined for naringin; the coefficient that best represents degradation was of first order and naringenin presented a zero-order kinetics. To our knowledge, a rapid and sensitive method for naringin and naringenin in polymeric nanoparticles has not been published elsewhere and this method is applicable to simultaneous evaluation of flavonoids. PMID:26053258

  18. Rapid determination of technetium-99 in large volume seawater samples using sequential injection extraction chromatographic separation and ICP-MS measurement.

    PubMed

    Shi, Keliang; Qiao, Jixin; Wu, Wangsuo; Roos, Per; Hou, Xiaolin

    2012-08-01

    An automated method was developed for rapid determination of (99)Tc in large volume seawater samples. The analytical procedure involves preconcentration of technetium with coprecipitation, online separation using extraction chromatography (two TEVA columns) implemented in a sequential injection setup, and measurement of (99)Tc by inductively coupled plasma mass spectrometry (ICP-MS). Chromatographic behaviors of technetium, molybdenum, and ruthenium were investigated, and the mechanism of adsorption and elution of TcO(4)(-) on a TEVA column using HNO(3) was explored. The results show that not only NO(3)(-) but also acidity (or concentration of H(+)) of the loading or eluting solution affect the adsorption and desorption of TcO(4)(-) on TEVA resin. Decontamination factors of more than 1 × 10(6) for ruthenium and 5 × 10(5) for molybdenum are achieved. Chemical yields of technetium in the overall procedure range from 60% to 75% depending on the sample volumes, and a detection limit of 7.5 mBq/m(3) (or 11.5 pg/m(3)) for 200 L of seawater was obtained. Compared with the conventional analytical procedure, the developed method significantly reduces analytical time. A batch of samples (n > 4) can be analyzed within 24 h. The method has been successfully applied for rapid and automated determination of low level (99)Tc in large volume seawater samples. The analytical results of seawater samples collected in Denmark show a good agreement with the values obtained using the conventional method. PMID:22783983

  19. Ion exchange chromatographic separation and isolation of oligosaccharides of intact low-molecular-weight heparin for the determination of their anticoagulant and anti-inflammatory properties.

    PubMed

    Shastri, Madhur D; Johns, Cameron; Hutchinson, Joseph P; Khandagale, Manish; Patel, Rahul P

    2013-07-01

    It is well known that enoxaparin, a widely used anticoagulant and low-molecular-weight heparin containing a large number of oligosaccharides, possesses anti-inflammatory activity. Whilst enoxaparin has shown promising results in various inflammatory disorders, some of its oligosaccharides have anti-inflammatory properties and others increase the risk of bleeding due to their anticoagulant effects. The aim of this study was to develop an effective ion exchange chromatographic (IC) technique which allows the separation, isolation and, consequently, the identification of different oligosaccharides of enoxaparin with or without anticoagulant activity. The developed method utilises a semi-preparative CarboPac PA100 (9 × 250 mm) ion exchange column with sodium chloride gradient elution and UV detection at 232 nm. The method successfully resolved enoxaparin into more than 30 different peaks. IC-derived oligosaccharides with high, moderate, low or no anticoagulant activity were identified using an anti-factor Xa assay. The anti-inflammatory activity of selected oligosaccharides was investigated using the Griess assay. Using this technique, the oligosaccharides of enoxaparin with low or no anticoagulant activity, whilst exhibiting significant anti-inflammatory activity, could be fractionated. This technique can provide a platform to identify the oligosaccharides which are devoid of significant anticoagulant activity and are responsible for the therapeutic effects of enoxaparin that have been observed in various inflammatory conditions. PMID:23712644

  20. Rapid chromatographic separation of dissoluble Ag(I) and silver-containing nanoparticles of 1-100 nanometer in antibacterial products and environmental waters.

    PubMed

    Zhou, Xiao-Xia; Liu, Rui; Liu, Jing-Fu

    2014-12-16

    Sensitive and rapid methods for speciation analysis of nanoparticulate Ag (NAg) and Ag(I) in complex matrices are urgently needed for understanding the environmental effects and biological toxicity of silver nanoparticles (AgNPs). Herein we report the development of a universal liquid chromatography (LC) method for rapid and high resolution separation of dissoluble Ag(I) from nanoparticles covering the entire range of 1-100 nm in 5 min. By using a 500 Å poresize amino column, and an aqueous mobile phase containing 0.1% (v/v) FL-70 (a surfactant) and 2 mM Na2S2O3 at a flow rate of 0.7 mL/min, all the nanoparticles of various species such as Ag and Ag2S were eluted in one fraction, while dissoluble Ag(I) was eluted as a baseline separated peak. The dissoluble Ag(I) was quantified by the online coupled ICP-MS with a detection limit of 0.019 μg/L. The NAg was quantified by subtracting the dissoluble Ag(I) from the total Ag content, which was determined by ICP-MS after digestion of the sample without LC separation. While the addition of FL-70 and Na2S2O3 into the mobile phase is essential to elute NAg and Ag(I) from the column, the use of 500 Å poresize column is the key to baseline separation of Ag(I) from ∼ 1 nm AgNPs. The feasibility of the proposed method was demonstrated in speciation analysis of dissoluble Ag(I) and NAg in antibacterial products and environmental waters, with very good chromatographic repeatability (relative standard deviations) in both peak area (<2%) and retention time (<0.6%), excellent spiked recoveries in the range of 84.7-102.7% for Ag(I) and 81.3-106.3% for NAg. Our work offers a novel approach to rapid and baseline separation of dissoluble metal ions from their nanoparticulate counterparts covering the whole range of 1-100 nm. PMID:25417798

  1. O-Allylation of phenols with allylic acetates in aqueous media using a magnetically separable catalytic system

    EPA Science Inventory

    Allylic ethers were synthesized in water using magnetically recoverable heterogeneous Pd catalyst via O-allylation of phenols with allylic acetates under ambient conditions. Aqueous reaction medium, easy recovery of the catalyst using an external magnet, efficient recycling, and ...

  2. Improvement of the chromatographic separation performance of an imidazolium ionic liquid functionalized silica column by in situ anion-exchange with dodecyl sulfonate and dodecylbenzene sulfonate anions.

    PubMed

    Sun, Min; Feng, Juanjuan; Chen, Wenjie; Li, Leilei; Duan, Huimin; Luo, Chuannan

    2014-06-01

    The anionic part of ionic liquids can provide additional interactions during chromatographic separations. In this work, the chromatographic separation performance of a silica column functionalized with 1-propyl-3-methylimidazolium chloride ionic liquid was improved by in situ anion-exchange from chloride anions to dodecyl sulfonate anions and dodecylbenzene sulfonate anions. The separation performances of these ionic liquid functionalized phases were investigated and compared with each other using polycyclic aromatic hydrocarbons, phthalates, parabens, and phenols as model compounds. Results indicated that the new columns presented a better chromatographic separation than the original one. This was ascribed retention mechanism from organic anions. The introduction of dodecyl sulfonate anions increased the hydrophobicity of stationary phase. Furthermore, the phenyl groups of dodecylbenzene sulfonate anions could provide an enhanced selectivity to aromatic compounds such as polycyclic aromatic hydrocarbons by π-π interactions. Analysis repeatability of the new columns was satisfactory (RSD of retention time, 0.10-0.40%; RSD of peak area, 0.66-0.84%). PMID:24616155

  3. Deconvolution of gas chromatographic data

    NASA Technical Reports Server (NTRS)

    Howard, S.; Rayborn, G. H.

    1980-01-01

    The use of deconvolution methods on gas chromatographic data to obtain an accurate determination of the relative amounts of each material present by mathematically separating the merged peaks is discussed. Data were obtained on a gas chromatograph with a flame ionization detector. Chromatograms of five xylenes with differing degrees of separation were generated by varying the column temperature at selected rates. The merged peaks were then successfully separated by deconvolution. The concept of function continuation in the frequency domain was introduced in striving to reach the theoretical limit of accuracy, but proved to be only partially successful.

  4. Exploitation of nano alumina for the chromatographic separation of clinical grade 188Re from 188W: a renaissance of the 188W/188Re generator technology.

    PubMed

    Chakravarty, Rubel; Shukla, Rakesh; Ram, Ramu; Venkatesh, Meera; Tyagi, Avesh Kumar; Dash, Ashutosh

    2011-08-15

    The (188)W/(188)Re generator using an acidic alumina column for chromatographic separation of (188)Re has remained the most popular procedure world over. The capacity of bulk alumina for taking up tungstate ions is limited (∼50 mg W/g) necessitating the use of very high specific activity (188)W (185-370 GBq/g), which can be produced only in very few high flux reactors available in the world. In this context, the use of high-capacity sorbents would not only mitigate the requirement of high specific activity (188)W but also facilitate easy access to (188)Re. A solid state mechanochemical approach to synthesize nanocrystalline γ-Al(2)O(3) possessing very high W-sorption capacity (500 mg W/g) was developed. The structural and other investigations of the material were carried out using X-ray diffraction (XRD), transmission electron microscopy (TEM), Brunauer Emmett Teller (BET) surface area analysis, thermogravimetric-differential thermal analysis (TG-DTA), and dynamic light scattering (DLS) techniques. The synthesized material had an average crystallite size of ∼5 nm and surface area of 252 ± 10 m(2)/g. Sorption characteristics such as distribution ratios (K(d)), capacity, breakthrough profile, and elution behavior were investigated to ensure quantitative uptake of (188)W and selective elution of (188)Re. A 11.1 GBq (300 mCi) (188)W/(188)Re generator was developed using nanocrystalline γ-Al(2)O(3), and its performance was evaluated for a period of 6 months. The overall yield of (188)Re was >80%, with >99.999% radionuclidic purity and >99% radiochemical purity. The eluted (188)Re possessed appreciably high radioactive concentration and was compatible for the preparation of (188)Re labeled radiopharmaceuticals. PMID:21726091

  5. Carbon-isotopic analysis of dissolved acetate

    NASA Technical Reports Server (NTRS)

    Gelwicks, J. T.; Hayes, J. M.

    1990-01-01

    Heating of dried, acetate-containing solids together with oxalic acid dihydrate conveniently releases acetic acid for purification by gas chromatography. For determination of the carbon-isotopic composition of total acetate, the acetate-containing zone of the chromatographic effluent can be routed directly to a combustion furnace coupled to a vacuum system allowing recovery, purification, and packaging of CO2 for mass-spectrometric analysis. For analysis of methyl carbon, acetic acid can be cryogenically trapped from the chromatographic effluent, then transferred to a tube containing excess NaOH. The tube is evacuated, sealed, and heated to 500 degrees C to produce methane by pyrolysis of sodium acetate. Subsequent combustion of the methane allows determination of the 13C content at the methyl position in the parent acetate. With typical blanks, the standard deviation of single analyses is less than 0.4% for acetate samples larger than 5 micromoles. A full treatment of uncertainties is outlined.

  6. A Small-Scale Low-Cost Gas Chromatograph

    ERIC Educational Resources Information Center

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  7. Design of a novel coil satellite centrifuge and its performance on counter-current chromatographic separation of 4-methylumbelliferyl sugar derivatives with organic-aqueous two-phase solvent systems

    PubMed Central

    Shinomiya, Kazufusa; Tokura, Koji; Kimura, Emiru; Takai, Midori; Harikai, Naoki; Yoshida, Kazunori; Yanagidaira, Kazuhiro; Ito, Yoichiro

    2015-01-01

    A new high-speed counter-current chromatograph, named coil satellite centrifuge (CSC), was designed and fabricated in our laboratory. The CSC apparatus produces the satellite motion such that the coiled column simultaneously rotates around the sun axis (the angular velocity, ω1), the planet axis (ω2) and the satellite axis (the central axis of the column) (ω3). In order to achieve this triplicate rotary motion without twisting of the flow tube, the rotation of each axis was determined by the following formula: ω1 = ω2 + ω3. This relation enabled to lay out the flow tube by two different ways, the SS type and the JS type. In the SS type, the flow tube was introduced from the upper side of the apparatus into the sun axis of the first rotary frame and connected to the planet axis of the second rotary frame like a double letter SS. In the JS type, the flow tube was introduced from the bottom of the apparatus into the sun axis reaching the upper side of the planet axis an inversed letter J, followed by distribution as in the SS type. The performance of the apparatus was examined on separation of 4-methylumbelliferyl (MU) sugar derivatives as test samples with organic-aqueous two-phase solvent systems composed of ethyl acetate/1-butanol/water (3 : 2 : 5, v/v) for lower phase mobile and (1 : 4 : 5, v/v) for upper phase mobile. With lower phase mobile, five 4-MU sugar derivatives including β-D-cellobioside (Cel), β-D-glucopyranoside, α-D-mannopyranoside, β-D-fucopyranoside and α-L-fucopyranoside (α-L-Fuc) were separated with the combined rotation around each axis at counterclockwise (CCW) (ω1) – CCW (ω2) – CCW (ω3) by the JS type flow tube distribution. With upper phase mobile, three 4-MU sugar derivatives including α-L-Fuc, β-D-galactopyranoside and Cel were separated with the combined rotation around each axis at clockwise (CW) (ω1) – CW (ω2) – CW (ω3) by the JS type flow tube distribution. A series of experiments on peak resolution and

  8. Ethyl acetate-n-butanol gradient solvent system for high-speed countercurrent chromatography to screen bioactive substances in okra.

    PubMed

    Ying, Hao; Jiang, Heyuan; Liu, Huan; Chen, Fangjuan; Du, Qizhen

    2014-09-12

    High-speed countercurrent chromatographic separation (HSCCC) possesses the property of zero-loss of sample, which is very useful for the screening of bioactive components. In the present study, the ethyl acetate-n-butanol gradient HSCCC solvent system composed of n-hexane-ethyl acetate-n-butanol-water was investigated for the screening of bioactive substances. To screen the antiproliferative compounds in okra extract, we used the stationary phase ethyl acetate-n-butanol-water (1:1:10) as the stationary phase, and eluted the antiproliferative components by 6-steps of gradient using mobile phases n-hexane-ethyl acetate (1:2), n-hexane-ethyl acetate (1:4), n-hexane-ethyl acetate (0:4), n-butanol-ethyl acetate (1:4) n-butanol-ethyl acetate (1:2), n-butanol-ethyl acetate (2:2), and n-butanol-ethyl acetate (2:1). The fractions collected from HSCCC separation with the gradient solvent system were assayed for antiproliferative activity against cancer cells. Bioactive components were identified: a major anti-cancer compound, 4'-hydroxy phenethyl trans-ferulate, with middle activity, and a minor anti-cancer compound, carolignan, with strong activity. The result shows that the gradient solvent system is potential for the screening of bioactive compounds from natural products. PMID:25069743

  9. Recent development in chromatographic techniques

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Chromatographic techniques play a significant role in the determination of analytes in complex matrices, separating individual sample components prior to their detection. In the analysis of contaminants and chemical residues in foods, gas chromatography (GC) and liquid chromatography (LC) are two m...

  10. Microminiature gas chromatograph

    DOEpatents

    Yu, C.M.

    1996-12-10

    A microminiature gas chromatograph ({mu}GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode. 7 figs.

  11. Microminiature gas chromatograph

    DOEpatents

    Yu, Conrad M.

    1996-01-01

    A microminiature gas chromatograph (.mu.GC) comprising a least one silicon wafer, a gas injector, a column, and a detector. The gas injector has a normally closed valve for introducing a mobile phase including a sample gas in a carrier gas. The valve is fully disposed in the silicon wafer(s). The column is a microcapillary in silicon crystal with a stationary phase and is mechanically connected to receive the mobile phase from the gas injector for the molecular separation of compounds in the sample gas. The detector is mechanically connected to the column for the analysis of the separated compounds of sample gas with electronic means, e.g., ion cell, field emitter and PIN diode.

  12. Vibrational Spectroscopy of Chromatographic Interfaces

    SciTech Connect

    Jeanne E. Pemberton

    2011-03-10

    Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

  13. Preparation of a chromatographic solid support on the basis of perlite, and separation of uranium on a tributyl-phosphate-loaded perlite column

    SciTech Connect

    Akcay, H.; Kilinc, S.; Karakas, R.

    1998-09-01

    The SiO{sub 2} content of the mineral perlite, which is the 70--75% range, was converted to soluble silicates with NaOH. The acidification of soluble silicates in the perlite formed hydrogels which turned into xerogels upon drying. Several parameters, particle size, specific surface area, pore size and volume, and surface hydroxyl group density were investigated for perlite standardized by NaOH. The standardized perlite was silanized and loaded with 20% (w/w) tributyl phosphate before use as a reversed-phase column chromatography solid support for the investigation of the chromatographic behavior of UO{sub 2}{sup 2+} and Fe{sup 3+}.

  14. Two chromatographic methods for the determination of some antimigraine drugs.

    PubMed

    El-Bagary, Ramzia I; Mohammed, Nashwah G; Nasr, Heba A

    2012-01-01

    Two stability indicating chromatographic methods were proposed for the determination of almotriptan, eletriptan, and rizatriptan, in presence of their acid degradation products. The first method is a quantitative densitometric thin layer chromatography. The developing systems were; acetonitrile: methanol: dichloromethane: ammonia (10:6:3:1 v/v), ethyl acetate: methanol: ammonia (15:4:1 v/v), and methanol: acetonitrile: ammonia (9:4:1 v/v) for almotriptan, eletriptan and rizatriptan respectively. The TLC plates were scanned at 235 nm. Linear relationships were obtained over concentration ranges (5-50 μg/spot) for almotriptan and rizatriptan, and (5-60 μg/spot) for eletriptan. The second method based on the separation and determination of the studied drugs, using RP-HPLC technique. The separation was achieved on C18 Hypersil column, elution was carried out using phosphate buffer pH 3: methanol: acetonitrile (2: 1:1 v/v) at flow rate 2 mL/min and UV detection at 235 nm. Linear relationships were obtained over concentration ranges (10-200 μg/mL) for almotriptan and eletriptan, and (10-180 μg/mL) for rizatriptan. The chromatographic methods were successfully applied for the determination of each of the studied drugs in pure form, tablet form, and in laboratory prepared mixtures with their acid degradation products. PMID:22654488

  15. Two Chromatographic Methods for the Determination of Some Antimigraine Drugs

    PubMed Central

    El-Bagary, Ramzia I.; Mohammed, Nashwah G.; Nasr, Heba A.

    2012-01-01

    Two stability indicating chromatographic methods were proposed for the determination of almotriptan, eletriptan, and rizatriptan, in presence of their acid degradation products. The first method is a quantitative densitometric thin layer chromatography. The developing systems were; acetonitrile: methanol: dichloromethane: ammonia (10:6:3:1 v/v), ethyl acetate: methanol: ammonia (15:4:1 v/v), and methanol: acetonitrile: ammonia (9:4:1 v/v) for almotriptan, eletriptan and rizatriptan respectively. The TLC plates were scanned at 235 nm. Linear relationships were obtained over concentration ranges (5–50 μg/spot) for almotriptan and rizatriptan, and (5–60 μg/spot) for eletriptan. The second method based on the separation and determination of the studied drugs, using RP-HPLC technique. The separation was achieved on C18 Hypersil column, elution was carried out using phosphate buffer pH 3: methanol: acetonitrile (2: 1:1 v/v) at flow rate 2 mL/min and UV detection at 235 nm. Linear relationships were obtained over concentration ranges (10–200 μg/mL) for almotriptan and eletriptan, and (10–180 μg/mL) for rizatriptan. The chromatographic methods were successfully applied for the determination of each of the studied drugs in pure form, tablet form, and in laboratory prepared mixtures with their acid degradation products. PMID:22654488

  16. Development and validation of an enantioselective liquid-chromatography/tandem mass spectrometry method for the separation and quantification of eslicarbazepine acetate, eslicarbazepine, R-licarbazepine and oxcarbazepine in human plasma.

    PubMed

    Loureiro, A I; Fernandes-Lopes, C; Wright, L C; Soares-da-Silva, P

    2011-09-01

    The purpose of this study was develop and validate a sensitive and specific enantioselective liquid-chromatography/tandem mass spectrometry (LC-MS/MS) method, for the simultaneous quantification of eslicarbazepine acetate (ESL), eslicarbazepine (S-Lic), oxcarbazepine (OXC) and R-licarbazepine (R-Lic) in human plasma. Analytes were extracted from human plasma using solid phase extraction and the chromatographic separation was achieved using a mobile phase of 80% n-hexane and 20% ethanol/isopropyl alcohol (66.7/33.3, v/v). A Daicel CHIRALCEL OD-H column (5 μm, 50 mm × 4.6 mm) was used with a flow rate of 0.8 mL/min, and a run time of 8 min. ESL, S-Lic, R-Lic, OXC and the internal standard, 10,11-dihydrocarbamazepine, were quantified by positive ion electrospray ionization mass spectrometry. The method was fully validated, demonstrating acceptable accuracy, precision, linearity, and specificity in accordance with FDA regulations for the validation of bioanalytical methods. Linearity was proven over the range of 50.0-1000.0 ng/mL for ESL and OXC and over the range of 50.0-25,000.0 ng/mL for S-Lic and R-Lic. The intra- and inter-day coefficient of variation in plasma was less than 9.7% for ESL, 6.0% for OXC, 7.7% for S-Lic and less than 12.6% for R-Lic. The accuracy was between 98.7% and 107.2% for all the compounds quantified. The lower limit of quantification (LLOQ) was 50.0ng/mL for ESL, S-Lic, OXC and R-Lic in human plasma. The short-term stability in plasma, freeze-thaw stability in plasma, frozen long-term stability in plasma, autosampler stability and stock solution stability all met acceptance criteria. The human plasma samples, collected from 8 volunteers, showed that this method can be used for therapeutic monitoring of ESL and its metabolites in humans treated with ESL. PMID:21816689

  17. A new direct laser photo-induced fluorescence method coupled on-line with liquid chromatographic separation for the simultaneous determination of anilides pesticides.

    PubMed

    Mbaye, O M A; Maroto, A; Gaye-Seye, M D; Stephan, L; Deschamps, L; Aaron, J J; Giamarchi, P

    2015-01-01

    A new direct laser photo-induced fluorescence high performance liquid chromatography (DL-PIF-HPLC) method is developed for the simultaneous determination of three anilide pesticides, namely carboxin, monalide and propanil. DL-PIF-HPLC uses a tunable Nd:YAG-OPO laser to obtain fluorescent photoproduct(s) and to simultaneously analyze their fluorescence in a short acquisition time with an intensified CCD camera, which improves the selectivity (by choosing the suitable excitation wavelength), increases the sensitivity (due to the high energy of the laser beam) and reduces the time of analysis, relative to the classical PIF methods. However, one of the main drawbacks of PIF methods is the presence of interferences with other compounds, such as other pesticides from the same group yielding similar fluorescent photoproducts, which reduces their selectivity. The analytical interest of DL-PIF-HPLC to avoid these interferences is demonstrated. The DL-PIF spectra, chromatographic conditions and analytical performances of DL-PIF-HPLC are presented for the simultaneous determination of three anilide pesticides. The calibration curves are linear over one order of magnitude and the limits of detection are in the ng mL(-1) range. The new DL-PIF-HPLC system has the advantage to combine the performances of both techniques, DL-PIF and liquid chromatography, and to improve the analysis selectivity. PMID:25476396

  18. Reversed-Phase High-Performance Liquid Chromatographic Separation of Inorganic Mercury And Methylmercury Driven By Their Different Coordination Chemistry Towards Thiols

    SciTech Connect

    Percy, A.J.; Korbas, M.; George, G.N.; Gailer, J.

    2009-06-02

    Since mercuric mercury (Hg{sup 2+}) and methylmercury (CH{sub 3}Hg{sup +}) display different toxicological properties in mammals, methods for their quantification in dietary items must be available. Employing Hg-specific detection, we have developed a rapid, isocratic, and affordable RP-HPLC separation of these mercurials using thiol-containing mobile phases. Optimal separation was achieved with a 50 mM phosphate-buffer containing 10 mM L-cysteine at pH 7.5. The separation is driven by the on-column formation of complexes between each mercurial and L-cysteine, which are then separated according to their different hydrophobicities. The developed method is compatible with inductively coupled plasma atomic emission spectrometry and was applied to analyze spiked human urine.

  19. High-separation efficiency micro-fabricated multi-capillary gas chromatographic columns for simulants of the nerve agents and blister agents

    PubMed Central

    2014-01-01

    To achieve both high speed and separation efficiency in the separation of a mixture of nerve and blister agent simulants, a high-aspect-ratio micro-fabricated multi-capillary column (MCC, a 50-cm-long, 450-μm-deep, and 60-μm-wide four-capillary column) was fabricated by the application of the microelectromechanical system (MEMS) techniques. Mixtures of chemical warfare agent (CWA) simulants - dimethyl methylphosphonate (DMMP), triethyl phosphate (TEP), and methyl salicylate - were used as samples. The fabricated MCC allowed for the separation of all the components of the gaseous mixture within 24 s, even when the difference in boiling point was 4°C, as in the case of TEP and methyl salicylate. Furthermore, interfering agents - dichloromethane, ethanol, and toluene - were also included in the subsequent gaseous mixture samples. The boiling point of these six components ranged from 78°C to 219°C. All six components were clearly separated within 70 s. This study is the first to report the clear separation of gas mixtures of components with close boiling points. The column efficiency was experimentally determined to be 12,810 plates/m. PMID:24899869

  20. High-separation efficiency micro-fabricated multi-capillary gas chromatographic columns for simulants of the nerve agents and blister agents

    NASA Astrophysics Data System (ADS)

    Li, Yi; Du, Xiaosong; Wang, Yang; Tai, Huiling; Qiu, Dong; Lin, Qinghao; Jiang, Yadong

    2014-05-01

    To achieve both high speed and separation efficiency in the separation of a mixture of nerve and blister agent simulants, a high-aspect-ratio micro-fabricated multi-capillary column (MCC, a 50-cm-long, 450-μm-deep, and 60-μm-wide four-capillary column) was fabricated by the application of the microelectromechanical system (MEMS) techniques. Mixtures of chemical warfare agent (CWA) simulants - dimethyl methylphosphonate (DMMP), triethyl phosphate (TEP), and methyl salicylate - were used as samples. The fabricated MCC allowed for the separation of all the components of the gaseous mixture within 24 s, even when the difference in boiling point was 4°C, as in the case of TEP and methyl salicylate. Furthermore, interfering agents - dichloromethane, ethanol, and toluene - were also included in the subsequent gaseous mixture samples. The boiling point of these six components ranged from 78°C to 219°C. All six components were clearly separated within 70 s. This study is the first to report the clear separation of gas mixtures of components with close boiling points. The column efficiency was experimentally determined to be 12,810 plates/m.

  1. Chromatographic separation of simulants of nerve and blister agents by combining one- and two-channel columns with different stationary phases.

    PubMed

    Yuan, Huan; Du, Xiaosong; Li, Yi; Zhao, Xulan; Xu, Ming

    2016-04-01

    A two-channel gas chromatography column and a single-channel column were made by deep reactive-ion etching technology. The two short columns were coated with different stationary phases, and then linked without a modulator. This is to aim at increasing the sample capacity and achieving a higher separation efficiency in complex environments. The results show that the capacity of the connected column is approximately 4 and 1.5 times larger than that of the single- and two-channel columns, respectively. The linked column was utilized to separate a six-component mixture, composed of three simulants of nerve and blister agents and three interfering vapors. The results demonstrate that the combined column has a remarkably higher separation efficiency than the individual columns, and an acceptable resolution is achieved although the total length of the linked column is only 1.5 m. PMID:26843525

  2. High-performance liquid chromatographic separation of natural and synthetic desulphoglucosinolates and their chemical validation by UV, NMR and chemical ionisation-MS methods.

    PubMed

    Kiddle, G; Bennett, R N; Botting, N P; Davidson, N E; Robertson, A A; Wallsgrove, R M

    2001-01-01

    Methods are described for the optimised extraction, desulphation and HPLC separation of desulphoglucosinolates. These methods provide rapid separation, identification and quantitative measurements of glucosinolates extracted from Brassica napus L and related crops, of unusual glucosinolates found in crucifer weed species, and also of synthetic alkylglucosinolates. The desulphoglucosinolates used in these studies were either chemically synthesised (at least one example from each major structural class), or purified from various plant sources. Validation of the identities of the desulphoglucosinolates was by comparison of retention times with standards, and by UV, 1H- and 13C-NMR and chemical ionisation MS analysis. A list of useful species, and the specific tissues, from which high concentrations of standards can be extracted is included. PMID:11705329

  3. Ultra high pressure in the second dimension of a comprehensive two-dimensional liquid chromatographic system for carotenoid separation in red chili peppers.

    PubMed

    Cacciola, Francesco; Donato, Paola; Giuffrida, Daniele; Torre, Germana; Dugo, Paola; Mondello, Luigi

    2012-09-14

    A comprehensive normal-phase × reversed-phase (NP-LC × RP-LC) liquid chromatography system was developed, and applied for analysis of the intact carotenoid composition of red chili peppers, with photodiode array and mass spectrometry detection. A micro-bore cyano column (250 mm × 1.0 mm, 5 μm d.p.) was chosen for the first dimension ((1)D) separation, interfaced to a second dimension ((2)D) C18 column (30 mm × 4.6 mm, 2.7 μm d.p.) packed with fused-core particles. Subsequently, two columns of the same stationary phase were coupled serially for second dimension separation, and operated under ultra high pressure LC conditions (UHPLC), within a cycle time of 1.50 or 1.00 min, and equal modulation times. Performances of the three different set-ups were evaluated, in terms of peak capacity values (n(c)), and afterwards corrected by taking into account both the under-sampling, and the orthogonality effects. After these adjustments, the peak capacity values were estimated as follows: n(c) 526, for the NP-LC × RP-LC system, n(c) 373, for the NP-LC × RP-UHPLC system with a 1.50 min modulation time, n(c) 639, for the NP-LC × RP-UHPLC system, with a 1.00 min modulation time. A total of 33 compounds were separated into 10 different chemical classes in the two-dimensional space, and identified by accurate IT-TOF (ion trap-time of flight) MS detection. PMID:22796028

  4. New reversed phase-high performance liquid chromatographic method for selective separation of yttrium from all rare earth elements employing nitrilotriacetate complexes in anion exchange mode.

    PubMed

    Dybczyński, Rajmund S; Kulisa, Krzysztof; Pyszynska, Marta; Bojanowska-Czajka, Anna

    2015-03-20

    Separation of Y from other rare earth elements (REE) is difficult because of similarity of its ionic radius to ionic radii of Tb, Dy and Ho. In the new RP-HPLC system with C18 column, tetra-n-butyl ammonium hydroxide (TBAOH) as an ion interaction reagent (IIR), nitrilotriacetic acid (NTA) as a complexing agent at pH=2.8-3.5, and post column derivatization with Arsenazo III, yttrium is eluted in the region of light REE, between Nd and Sm and is base line separated from Nd and Sm and even from promethium. Simple model employing literature data on complex formation of REE with NTA and based on anion exchange mechanism was developed to foresee the order of elution of individual REE. The model correctly predicted that lanthanides up to Tb will be eluted in the order of increasing Atomic Number (At.No.) but all heavier REE will show smaller retention factors than Tb. Concurrent UV/VIS detection at 658nm and the use of radioactive tracers together with γ-ray spectrometric measurements made possible to establish an unique elution order of elution of REE: La, Ce, Pr, Nd, Pm, Y, Sm, Er, Ho, Tm, Yb, Eu, Lu, Dy+Gd, Tb, Sc. The real place of Y however, in this elution series differs from that predicted by the model (Y between Sm and Eu). The method described in this work enables selective separation of Y from La, Ce, Pr, Nd, Pm, Sm and all heavier REE treated as a group. PMID:25700726

  5. Coal liquefaction process streams characterization and evaluation: Application of liquid chromatographic separation methods to THF-soluble portions of integrated two-stage coal liquefaction resids

    SciTech Connect

    Green, J.B.; Pearson, C.D.; Young, L.L.; Green, J.A. )

    1992-05-01

    This study demonstrated the feasibility of using non-aqueous ion exchange liquid chromatography (NIELC) for the examination of the tetrahydrofuran (THF)-soluble distillation resids and THF-soluble whole oils derived from direct coal liquefaction. The technique can be used to separate the material into a number of acid, base, and neutral fractions. Each of the fractions obtained by NIELC was analyzed and then further fractionated by high-performance liquid chromatography (HPLC). The separation and analysis schemes are given in the accompanying report. With this approach, differences can be distinguished among samples obtained from different process streams in the liquefaction plant and among samples obtained at the same sampling location, but produced from different feed coals. HPLC was directly applied to one THF-soluble whole process oil without the NIELC preparation, with limited success. The direct HPLC technique used was directed toward the elution of the acid species into defined classes. The non-retained neutral and basic components of the oil were not analyzable by the direct HPLC method because of solubility limitations. Sample solubility is a major concern in the application of these techniques.

  6. Improvement in the Iatroscan thin-layer chromatographic-flame ionisation detection analysis of marine lipids. Separation and quantitation of monoacylglycerols and diacylglycerols in standards and natural samples.

    PubMed

    Striby, L; Lafont, R; Goutx, M

    1999-07-23

    Mono- and diacylglycerols are important intermediates in glycerolipid biodegradation and intracellular signalling pathways. A method for mass determination of these lipid classes in marine particles was developed using the Iatroscan, which combines thin layer chromatography (TLC) and flame ionisation detection (FID) techniques. We improved existing protocols by adding two elution steps: hexane-diethyl-ether-formic acid (70:30:0.2, v/v/v) after triacylglycerol and free fatty acid scan, and acetone 100% followed by chloroform-acetone-formic acid (99:1:0.2, v/v/v) after 1,2 diacylglycerols. Diacylglycerol isomers 1,2 and 1,3 were separated from each other, as well as from free sterols in standards and marine lipids from sediment trap particles. Monoacylglycerols were separated from pigments and galactosyl-lipids in the same trap samples and in a rich pigment phytoplankton extract of Dunaliella viridis. Quantitation of each class in samples was performed after calibration with 0.5 to 2 micrograms of standards. As many as 17 lipid classes can be identified and quantified in samples using this proposed six-step development. PMID:10457435

  7. Thermodynamic characteristics of sorption extraction and chromatographic separation of anionic complexes of erbium and cerium with Trilon B on weakly basic anionite

    NASA Astrophysics Data System (ADS)

    Cheremisina, O. V.; Ponomareva, M. A.; Sagdiev, V. N.

    2016-03-01

    The adsorption of anionic complexes of erbium with Trilon B on D-403 anionite is studied at ionic strengths of 1 and 2 mol/kg (NaNO3) and temperatures of 298 and 343 K. The values of the stability constants of complex ions of REE with Trilon B and the Gibbs energies of complexation are calculated. The values of the Gibbs energy and the enthalpy and entropy of ion exchange are determined. Using the obtained thermo-dynamic and sorption characteristics, the possible separation of anionic complexes of erbium and cerium with Trilon B is demonstrated via frontal ion-exchange chromatography. A series of sorption capacities of anionic complexes of cerium, yttrium, and erbium is presented using the values of the Gibbs energy of ion exchange.

  8. Role of substituents in cyclodextrin derivatives for enantioselective gas chromatographic separation of chiral terpenoids in the essential oils of Mentha spicata.

    PubMed

    Pragadheesh, V S; Yadav, Anju; Chanotiya, Chandan Singh

    2015-10-01

    Enantioselective GC-FID and enantioselective GC-MS have been utilized under temperature gradient mode with differently substituted heptakis- and octakis-cyclodextrins to achieve the resolution of chiral terpenoids in the essential oil of indigenously grown cultivars of Mentha spicata. Modified cyclodextrins were derivatized in GC column for the separation of chiral terpenoids. A 2,3-diethyl-6-tert-butyldimethylsilyl-β-cyclodextrin doped into 14% cyanopropylphenyl/86%dimethylpolysiloxane (TBDE-β-CD) showed good enantioselectivity for all the studied chiral compounds excluding carvone. Carvone enantiomers were well resolved in 2,3-diacetoxy-6-tert-butyldimethylsilyl-β-cyclodextrin column (TBDA-β-CD) with enantioseparation (Es) of 1.006. A TBDE-β-CD provides maximum enantiomeric separation for β-pinene (Es 1.038), sabinene (Es 1.051), limonene (Es 1.045), isomenthone (Es 1.029) and α-terpineol (Es 1.014). Furthermore, enantiomer elution order reversal was observed for sabinene, menthone, terpinen-4-ol and menthol while changing from β- to γ-cyclodextrin phase. Carvone exhibits enantiomer elution order reversal by changing substituents i.e., methyl to acetyl at 2- & 3- position of the cyclodextrin derivative. Chiral constituents such as (+)-isomenthone, (-)-menthone, (1R,2S,5R)-(-)-menthol and (4S)-(+)-piperitone exist as a single enantiomer with >99% excess. Existence of (R)-(+)-limonene and (S)-(+)-carvone enantiomers has been proven first time in M. spicata essential oils and can be used as the marker for Indian origin. PMID:26310896

  9. Partial least squares model and design of experiments toward the analysis of the metabolome of Jatropha gossypifolia leaves: Extraction and chromatographic fingerprint optimization.

    PubMed

    Pilon, Alan Cesar; Carnevale Neto, Fausto; Freire, Rafael Teixeira; Cardoso, Patrícia; Carneiro, Renato Lajarim; Da Silva Bolzani, Vanderlan; Castro-Gamboa, Ian

    2016-03-01

    A major challenge in metabolomic studies is how to extract and analyze an entire metabolome. So far, no single method was able to clearly complete this task in an efficient and reproducible way. In this work we proposed a sequential strategy for the extraction and chromatographic separation of metabolites from leaves Jatropha gossypifolia using a design of experiments and partial least square model. The effect of 14 different solvents on extraction process was evaluated and an optimized separation condition on liquid chromatography was estimated considering mobile phase composition and analysis time. The initial conditions of extraction using methanol and separation in 30 min between 5 and 100% water/methanol (1:1 v/v) with 0.1% of acetic acid, 20 μL sample volume, 3.0 mL min(-1) flow rate and 25°C column temperature led to 107 chromatographic peaks. After the optimization strategy using i-propanol/chloroform (1:1 v/v) for extraction, linear gradient elution of 60 min between 5 and 100% water/(acetonitrile/methanol 68:32 v/v with 0.1% of acetic acid), 30 μL sample volume, 2.0 mL min(-1) flow rate, and 30°C column temperature, we detected 140 chromatographic peaks, 30.84% more peaks compared to initial method. This is a reliable strategy using a limited number of experiments for metabolomics protocols. PMID:26757030

  10. Microminiature gas chromatographic column

    NASA Technical Reports Server (NTRS)

    Donaldson, R. W., Jr.

    1972-01-01

    Techniques commonly used for fabrication of integrated circuits are utilized to produce long capillary tubes for microminiature chromatographs. Method involves bonding of flat silicon plate to top of spirally grooved silicon chip to close groove and form capillary column.

  11. Radiostrontium and radium analysis in low-level environmental samples following a multi-stage semi-automated chromatographic sequential separation.

    PubMed

    St-Amant, Nadereh; Whyte, Jeffrey C; Rousseau, Marie-Eve; Lariviere, Dominic; Ungar, R Kurt; Johnson, Sonia

    2011-01-01

    Strontium isotopes, (89)Sr and (90)Sr, and (226)Ra being radiotoxic when ingested, are routinely monitored in milk and drinking water samples collected from different regions in Canada. In order to monitor environmental levels of activity, a novel semi-automated sensitive method has been developed at the Radiation Protection Bureau of Health Canada (Ottawa, Canada). This method allows the separation and quantification of both (89)Sr and (90)Sr and has also been adapted to quantify (226)Ra during the same sample preparation procedure. The method uses a 2-stage purification process during which matrix constituents, such as magnesium and calcium that are rich in milk, are removed as well as the main beta-interferences (e.g., (40)K, (87)Rb, (134)Cs, (137)Cs, and (140)Ba). The first purification step uses strong cation exchange (SCX) chromatography with commercially available resins. In a second step, fractions containing the radiostrontium analytes are further purified using high-performance ion chromatography (HPIC). While (89)Sr is quantified by Cerenkov counting immediately after the second purification stage, the same vial is counted again after a latent period of 10-14 days to quantify the (90)Sr activity based on (90)Y ingrowth. Similarly, the activity of (226)Ra, which is separated by SCX only, is determined via the emanation of (222)Rn in a 2-phase aqueous/cocktail system using liquid scintillation counting. The minimum detectable concentration (MDC) for (89)Sr and (90)Sr for a 200 min count time at 95% confidence interval is 0.03 and 0.02 Bq/L, respectively. The MDC for (226)Ra for a 100 min count time is 0.002 Bq/L. Semi-annual intercomparison samples from the USA Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP) were used to validate the method for (89)Sr and (90)Sr. Spiked water samples prepared in-house and from International Atomic Energy Agency (IAEA) were used to validate the (226)Ra assay. PMID:20846869

  12. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  13. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  14. Graphene-ZIF8 composite material as stationary phase for high-resolution gas chromatographic separations of aliphatic and aromatic isomers.

    PubMed

    Yang, Xiaohong; Li, Changxia; Qi, Meiling; Qu, Liangti

    2016-08-19

    This work presents the separation performance of graphene-ZIF8 (G-Z) composite material as stationary phase for capillary gas chromatography (GC). The G-Z stationary phase achieved high column efficiency of 5000 plates/m determined by n-dodecane (k=1.22) at 120°C and showed weakly polar nature. Importantly, it exhibited high selectivity and resolving capability for branched alkane isomers and aromatic positional isomers, showing clear advantages over the reported neat graphene and ZIF8. In addition, it attained high resolution for geometric cis-/trans-isomers. The G-Z column exhibited good column thermal stability up to 300°C and column repeatability with RSD values of retention times in the range of 0.01-0.19% for intra-day, 0.05-0.88% for inter-day and 0.66-5.6% for between-column, respectively, Moreover, the G-Z column was employed for the determination of minor impurity isomers in real reagent samples, which demonstrates its promising potential in GC applications. PMID:27423773

  15. Chromatographic separation of proteins on metal immobilized iminodiacetic acid-bound molded monolithic rods of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate).

    PubMed

    Luo, Q; Zou, H; Xiao, X; Guo, Z; Kong, L; Mao, X

    2001-08-17

    Continuous rod of macroporous poly(glycidyl methacrylate-co-ethylene dimethacrylate) was prepared by a free radical polymerization within the confines of a stainless-steel column. The epoxide groups of the rod were modified by a reaction with iminodiacetic acid (IDA) that affords the active site to form metal IDA chelates used for immobilized metal affinity chromatography (IMAC). The efficiency of coupling of IDA to the epoxide-contained matrix was studied as a function of reaction time and temperature. High-performance separation of proteins, based on immobilized different metals on the column, were described. The influence of pH on the adsorption capacity of bovine serum albumin on the Cu2+-IDA continuous rod column was investigated in the range from 5.0 to 9.0. Purification of lysozyme from egg white and human serum albumin (HSA) on the commercially available HSA solution were performed on the naked IDA and Cu2+-IDA continuous rod columns, respectively; and the purity of the obtained fractions was detected by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry. PMID:11556331

  16. A fluorous porous polymer monolith photo-patterned chromatographic column for the separation of a flourous/fluorescently labeled peptide within a microchip.

    PubMed

    Xu, Zhenpo; Oleschuk, Richard D

    2014-02-01

    A fluorous porous polymer stationary phase is photo-patterned within a glass microfluidic chip to conduct CEC. During free radical-initiated polymerization, extraneous polymer forms and contributes to excessive microfluidic channel clogging. Nitrobenzene is explored as free radical quencher to limit clogging by minimizing extraneous polymer formation and a number of initiator to quencher ratios are explored with a 0.5:1 quencher (nitrobenzene): initiator (benzoin methyl ether) molar ratio shown to be optimal. The microchip patterned with a fluorous monolith was used to carry out the electrochromatographic analysis of a mixture containing fluorescent and fluorous labeling products. The fluorous monolithic column shows fluorous selectivity for compounds labeled with perfluoromethylene tags and a custom peptide is synthesized that possesses functional groups that can be both fluorescently and fluorously labeled. MALDI MS was used to identify the labeled fragments and microchip based electrochromatography was used to analyze the resulting labeling mixture. This is the first report to our knowledge that uses fluorous porous polymer monolith within a microchip to separate analytes using fluorous-fluorous interactions. PMID:24170603

  17. Ultra-performance liquid chromatographic separation of geometric isomers of carotenoids and antioxidant activities of 20 tomato cultivars and breeding lines.

    PubMed

    Li, Hongyan; Deng, Zeyuan; Liu, Ronghua; Loewen, Steven; Tsao, Rong

    2012-05-01

    All-trans-lutein, lycopene, β-carotene and their 22 cis-isomers in 20 tomato breeding were separated and identified by a rapid and sensitive UPLC method using a 1.7μm C18 column and a new gradient mobile phase based on methanol-MTBE-water in 15 min. All-trans-carotenoids were predominant, but 9-cis, 13-cis-lutein, 5-cis, 9-cis, 13-cis, 15-cis, di-cis-lycopene, 9-cis, 13-cis, 15-cis and di-cis-β-carotene were also found. The cis-isomers were identified using absorption around 330nm and the Q-ratio. The total antioxidant activities as evaluated by PCL and DPPH assays were found to correlate well with the total carotenoid content, but not with the individual carotenoid or its different isomers. This paper provides an efficient analytical method for obtaining a complete picture of carotenoids in tomatoes. It can be a valuable tool for plant breeders, food processors and researchers in developing designer tomatoes and tomato-products with unique carotenoid compositions, and functional properties. PMID:26434324

  18. Stability of arsenic peptides in plant extracts: off-line versus on-line parallel elemental and molecular mass spectrometric detection for liquid chromatographic separation.

    PubMed

    Bluemlein, Katharina; Raab, Andrea; Feldmann, Jörg

    2009-01-01

    The instability of metal and metalloid complexes during analytical processes has always been an issue of an uncertainty regarding their speciation in plant extracts. Two different speciation protocols were compared regarding the analysis of arsenic phytochelatin (As(III)PC) complexes in fresh plant material. As the final step for separation/detection both methods used RP-HPLC simultaneously coupled to ICP-MS and ES-MS. However, one method was the often used off-line approach using two-dimensional separation, i.e. a pre-cleaning step using size-exclusion chromatography with subsequent fraction collection and freeze-drying prior to the analysis using RP-HPLC-ICP-MS and/or ES-MS. This approach revealed that less than 2% of the total arsenic was bound to peptides such as phytochelatins in the root extract of an arsenate exposed Thunbergia alata, whereas the direct on-line method showed that 83% of arsenic was bound to peptides, mainly as As(III)PC(3) and (GS)As(III)PC(2). Key analytical factors were identified which destabilise the As(III)PCs. The low pH of the mobile phase (0.1% formic acid) using RP-HPLC-ICP-MS/ES-MS stabilises the arsenic peptide complexes in the plant extract as well as the free peptide concentration, as shown by the kinetic disintegration study of the model compound As(III)(GS)(3) at pH 2.2 and 3.8. But only short half-lives of only a few hours were determined for the arsenic glutathione complex. Although As(III)PC(3) showed a ten times higher half-life (23 h) in a plant extract, the pre-cleaning step with subsequent fractionation in a mobile phase of pH 5.6 contributes to the destabilisation of the arsenic peptides in the off-line method. Furthermore, it was found that during a freeze-drying process more than 90% of an As(III)PC(3) complex and smaller free peptides such as PC(2) and PC(3) can be lost. Although the two-dimensional off-line method has been used successfully for other metal complexes, it is concluded here that the fractionation and

  19. Ion chromatographic separation and quantitation of alkyl methylamines and ethylamines in atmospheric gas and particulate matter using preconcentration and suppressed conductivity detection.

    PubMed

    VandenBoer, T C; Markovic, M Z; Petroff, A; Czar, M F; Borduas, N; Murphy, J G

    2012-08-24

    Two methods based on ion chromatography (IC) were developed for the detection of methyl and ethyl alkyl amines (methylamine (MA), ethylamine (EA), dimethylamine (DMA), diethylamine (DEA), trimethylamine (TMA) and triethylamine (TEA)) and NH(3)/NH(4)(+) in online atmospheric gas-particle and size-resolved particulate samples. The two IC methods were developed to analyze samples collected with an ambient ion monitor (AIM), an online gas-particle collection system, or with a Micro Orifice Uniform Deposit Impactor (MOUDI) for size-resolved particle samples. These methods enable selective and (semi-) quantitative detection of alkyl amines at ambient atmospheric concentrations (pptv and pgm(-3)) in samples where significant interferences can be expected from Na(+) and NH(4)(+), for example marine and rural air masses. Sample pre-concentration using a trace cation column enabled instrumental detection limits on the order of pmol (sub-ng) levels per sample, an improvement of up to 10(2) over current IC methods. Separation was achieved using a methanesulfonic acid gradient elution on Dionex CS12A and CS17 columns. The relative standard deviations in retention times during 3 weeks continuous (hourly) sampling campaigns ranged from 0.1 to 0.5% and 0.2 to 5% for the CS12A and CS17 across a wide dynamic range of atmospheric concentrations. Resolution of inorganic and organic cations is limited to 25min for online samples. Mass-dependent coelution of NH(4)(+)/MA/EA occurred on the CS12A column and DEA/TMA coeluted on both columns. Calibrations of ammonium show a non-linear response across the entire calibration range while all other analytes exhibit high linearity (R(2)=0.984-0.999), except for EA and TEA on the CS12A (R(2)=0.960 and 0.941, respectively). Both methods have high analytical accuracy for the nitrogenous bases ranging from 9.5 to 20% for NH(3) and <5-15% for the amines. Hourly observations of amines at Egbert, ON in October 2010 showed gaseous DMA and TMA+DEA at 1

  20. Ammonium acetate

    Integrated Risk Information System (IRIS)

    Ammonium acetate ; CASRN 631 - 61 - 8 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic

  1. Vinyl acetate

    Integrated Risk Information System (IRIS)

    Vinyl acetate ; CASRN 108 - 05 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  2. Ethyl acetate

    Integrated Risk Information System (IRIS)

    Ethyl acetate ; CASRN 141 - 78 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic Eff

  3. Phenylmercuric acetate

    Integrated Risk Information System (IRIS)

    Phenylmercuric acetate ; CASRN 62 - 38 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog

  4. Thallium acetate

    Integrated Risk Information System (IRIS)

    Jump to main content . Integrated Risk Information System Recent Additions | Contact Us Search : All EPA IRIS • You are here : EPA Home • Research • Environmental Assessment • IRIS • IRIS Summaries Redirect Page As of September 30 , 2009 , the assessment summary for Thallium acetate is included in t

  5. Analysis of chromatograph systems using orthogonal collocation

    NASA Technical Reports Server (NTRS)

    Woodrow, P. T.

    1974-01-01

    Research is generating fundamental engineering design techniques and concepts for the chromatographic separator of a chemical analysis system for an unmanned, Martian roving vehicle. A chromatograph model is developed which incorporates previously neglected transport mechanisms. The numerical technique of orthogonal collocation is studied. To establish the utility of the method, three models of increasing complexity are considered, the latter two being limiting cases of the derived model: (1) a simple, diffusion-convection model; (2) a rate of adsorption limited, inter-intraparticle model; and (3) an inter-intraparticle model with negligible mass transfer resistance.

  6. GAS CHROMATOGRAPHIC TECHNIQUES FOR THE MEASUREMENT OF ISOPRENE IN AIR

    EPA Science Inventory

    The chapter discusses gas chromatographic techniques for measuring isoprene in air. Such measurement basically consists of three parts: (1) collection of sufficient sample volume for representative and accurate quantitation, (2) separation (if necessary) of isoprene from interfer...

  7. NEW LIQUID CHROMATOGRAPHIC DETECTION SYSTEM FOR ENVIRONMENTAL POLLUTANTS

    EPA Science Inventory

    Resonance enhanced coherent anti-Stokes Raman spectrometry (CARS) has been demonstrated as a specific identification system for liquid chromatography for water pollution identification. To achieve this, liquid chromatographic preconcentration and separation and computer control o...

  8. Protecting Gas Chromatographic Syringes

    NASA Astrophysics Data System (ADS)

    Ruekberg, Ben

    1995-12-01

    This article describes the construction of a device which protects gas chromatographic syringes. The device lessens the likelihood of syringes rolling off tables and breaking. If the syringe is dropped, the glass barrel is less apt to be struck and shattered.

  9. Ion-exclusion chromatographic separations of C1-C6 aliphatic carboxylic acids on a sulfonated styrene-divinylbenzene co-polymer resin column with 5-methylhexanoic acid as eluent.

    PubMed

    Ohta, Kazutoku; Towata, Atsuya; Ohashi, Masayoshi

    2003-05-16

    The application of C7 aliphatic carboxylic acids (heptanoic, 2-methylhexanoic, 5-methylhexanoic and 2,2-dimethyl-n-valeric acids) as eluents in ion-exclusion chromatography with conductimetric detection for C1-C6 aliphatic carboxylic acids (formic, acetic, propionic, isobutyric, butyric, isovaleric, valeric, isocaproic and caproic acids) was carried out using a highly sulfonated styrene-divinylbenzene co-polymer resin (TSKgel SCX) in the H+ form as a stationary phase. When using 0.05 mM sulfuric acid at pH 4.0 as the eluent, peak shapes of hydrophobic carboxylic acids (isovaleric, valeric, isocaproic and caproic acids) were tailed strongly. In contrast, when using 1 mM these C7 carboxylic acids at pH ca. 4 as the eluents, although system peaks (vacant peaks) corresponding to these C7 carboxylic acids appeared, peak shapes of these hydrophobic acids were improved drastically. Excellent simultaneous separation and relatively high sensitive conductimetric detection for these C1-C6 aliphatic carboxylic acids were achieved in 25 min on the TSKgel SCX column (150 x 6 mm I.D.) using 1 mM 5-methylhexanoic acid at pH 4.0 as the eluent. PMID:12830882

  10. Calixarene-based extraction chromatographic separation of ¹³⁵Cs and ¹³⁷Cs in environmental and waste samples prior to sector field ICP-MS analysis.

    PubMed

    Russell, Ben C; Warwick, Phil E; Croudace, Ian W

    2014-12-01

    Advances in the sensitivities achievable by sector field inductively coupled plasma mass spectrometry (ICP-SFMS) offer the prospect of low-level measurement of shorter and longer lived radionuclides, thus expanding options for environmental and radioactively contaminated land assessment. In ICP-SFMS, the critical requirement for accurate detection is the effective chemical separation of isobaric and polyatomic interferences prior to sample introduction. As instrumental detection limit capability improves, accurate radionuclide determination requires highly effective separation materials that combine high analyte selectivity with subsequent quantitative analyte recovery compatible with ICP-SFMS detection. Two radioactive isotopes measurable by ICP-SFMS are the high yield fission products (135)Cs and (137)Cs that have entered the environment as a result of anthropogenic nuclear activities. ICP-SFMS enables reliable measurement of (135)Cs/(137)Cs ratios, which can be used as a forensic tool in determining the source of nuclear contamination. The critical requirement for accurate detection is the effective removal of isobaric interferences from (135)Ba and (137)Ba prior to measurement. A number of exchange materials can effectively extract Cs; however, non-quantitative elution of Cs makes subsequent ICP-SFMS quantification challenging. A novel extraction chromatographic resin has been developed by dissolving calix[4]arene-bis(tert-octylbenzo-crown-6) (BOBCalixC6) in octan-1-ol and loading onto an Amberchrom CG-71 prefilter resin material. Preparation of the material takes less than 1 h and, at an optimal concentration of 3 M HNO3, shows high selectivity toward Cs, which is effectively eluted in 0.05 M HNO3. The procedure developed shows high Cs selectivity and Ba decontamination from digests of complex matrixes including a saltmarsh sediment contaminated by aqueous discharges from a nuclear fuel reprocessing facility. Repeated tests show the resin can be reused up to

  11. ION-EXCLUSION CHROMATOGRAPHIC DETERMINATION OF CARBOXYLIC ACIDS USED TO SUPPORT THE MICROBIALLY MEDIATED REDUCTIVE DECHLORINATION OF TETRACHLOROETHENE

    EPA Science Inventory

    An analytical method was developed for the determination of lactic acid, formic acid, acetic acid, propionic acid, and butyric acid in environmental microcosm samples using ion-exclusion chromatography. The chromatographic behavior of various eluents was studied to determine the ...

  12. High-performance liquid chromatographic determination of methyl anthranilate, hydroxymethylfurfural and related compounds in honey.

    PubMed

    Nozal, M J; Bernal, J L; Toribio, L; Jiménez, J J; Martín, M T

    2001-05-11

    A high-performance liquid chromatographic method for determining 5-hydroxymethyl-2-furaldehyde (hydroxymethylfurfural), 2-furaldehyde (furfural), furan-2-carboxylic acid (2-furoic acid), furan-3-carboxylic acid (3-furoic acid), furan-3-carboxaldehyde (3-furaldehyde) and 2-aminobenzoic acid methyl ester (methyl anthranilate) in honey and honeydew samples is described. To prevent matrix interference and to isolate the compounds, a clean-up step which implies a solid-phase extraction on polymeric cartridges and an elution with 0.5 ml methanol is recommended. The compounds are separated on a reversed-phase column with a gradient of (A) 1% aqueous acetic acid-acetonitrile (97:3, v/v) and (B) acetonitrile-water (50:50, v/v), with UV detection at 250 nm. The method is applied to the analysis of samples from different botanical origin. PMID:11403496

  13. Liquid chromatographic determination of aniline in table-top sweeteners based on pre-column derivatization with 1,2-naphthoquinone-4-sulfonate.

    PubMed

    Hernando, D; Saurina, J; Hernández-Cassou, S

    1999-10-29

    A liquid chromatographic method for the determination of aniline in cyclamate sweeteners based on a pre-column derivatization with 1,2-naphthoquinone-4-sulfonate (NQS) is proposed. Aniline traces were extracted from the cyclamate samples using dichloromethane. After solvent evaporation, the dry residue was derivatized with NQS at pH 9.5 and 85 degrees C for 1 min. The aniline derivative, which was extracted from the reacting mixture, was redissolved in the eluent solution and injected into the chromatographic system. The separation of aniline derivative from other amine impurities was carried out in a C18 column using a 2% acetic acid-methanol (40:60, v/v) mobile phase. Results from the analysis of aniline in the sweetener samples with the proposed method were compared with those from the standard method. A good concordance between the two methods was observed. PMID:10574215

  14. Membrane filtration of Sudan orange G on a cellulose acetate membrane filter for separation-preconcentration and spectrophotometric determination in water, chili powder, chili sauce and tomato sauce samples.

    PubMed

    ALOthman, Zeid A; Unsal, Yunus E; Habila, Mohamed; Shabaka, Azza; Tuzen, Mustafa; Soylak, Mustafa

    2012-08-01

    A simple membrane filtration procedure for separation-enrichment of Sudan orange G is presented. The method is based on the adsorption of Sudan orange G on a cellulose acetate filter and its elution from the membrane with 10 mL of ethanol. Sudan orange G in the eluent was determined by UV-visible spectrophotometry at 388 nm. The effect of analytical conditions, including pH, flow rates and eluent, sample volume, type of membrane for quantitative preconcentration and separation of Sudan orange G were examined. The influences of matrix components on Sudan orange G recoveries were studied. The preconcentration factor was 125. The detection limit was 4.9 μg L(-1). The relative standard deviation was 4.3%. The presented procedure was applied to chili powder, chili sauce, tomato sauce, powdered beverage and water samples. PMID:22617351

  15. Nano-fabricated size exclusion chromatograph

    NASA Technical Reports Server (NTRS)

    Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; Castillo, L. del; White, V.

    2002-01-01

    This paper describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through amicrocolumn containing nano-fabricated features will have characteristic elution times that directly correlate to molecular weight. Compared to conventional size exclusion chromatography, the nSEC offers greater control over the size exclusion process; mass fabrication; integration of the separation column with associated valves, pumps, and detectors; and dramatic reductions in instrument mass and power requirements.

  16. Inhibition of Epstein-Barr virus lytic cycle by an ethyl acetate subfraction separated from Polygonum cuspidatum root and its major component, emodin.

    PubMed

    Yiu, Ching-Yi; Chen, Shih-Ying; Yang, Tsai-Hsiu; Chang, Che-Jung; Yeh, Dong-Bor; Chen, Yi-Jie; Lin, Tsuey-Pin

    2014-01-01

    Polygonum cuspidatum is widely used as a medicinal herb in Asia. In this study, we examined the ethyl acetate subfraction F3 obtained from P. cuspidatum root and its major component, emodin, for their capacity to inhibit the Epstein-Barr virus (EBV) lytic cycle. The cell viability was determined by the MTT [3-(4,5-dimethyldiazol-2-yl)-2,5-diphenyltetrazolium bromide] method. The expression of EBV lytic proteins was analyzed by immunoblot, indirect immunofluorescence and flow cytometric assays. Real-time quantitative PCR was used to assess the EBV DNA replication and the transcription of lytic genes, including BRLF1 and BZLF1. Results showed that the F3 and its major component emodin inhibit the transcription of EBV immediate early genes, the expression of EBV lytic proteins, including Rta, Zta, and EA-D and reduces EBV DNA replication, showing that F3 and emodin are potentially useful as an anti-EBV drug. PMID:24448066

  17. Liquid chromatographic resolution of 3-amino-1,4-benzodiazepin-2-ones on crown ether-based chiral stationary phases.

    PubMed

    Park, Je Young; Jin, Kab Bong; Hyun, Myung Ho

    2012-05-01

    3-Amino-5-phenyl (or 5-methyl)-1,4-benzodiazepin-2-ones, which are chiral precursors of anti-respiratory syncytial virus active agents, were resolved on three different chiral stationary phases (CSPs) based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid or (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6. Among the three CSPs, the CSP that is based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6 and containing residual silanol group-protecting n-octyl groups on the silica surface was found to be most effective with the use of 80% ethanol in water containing perchloric acid (10 mM) and ammonium acetate (1.0 mM) as a mobile phase. The separation factors (α) and resolutions (R(S) ) were in the range of 1.90-3.21 and 2.79-5.96, respectively. From the relationship between the analyte structure and the chromatographic resolution behavior, the chiral recognition mechanism on the CSP based on (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid was proposed to be different from that on the CSP based on (3,3'-diphenyl-1,1'-binaphthyl)-20-crown-6. In addition, the chromatographic resolution behavior of the most effective CSP was investigated as a function of the composition of aqueous mobile phase containing organic and acidic modifier and ammonium acetate. PMID:22508444

  18. An open tubular ion chromatograph.

    PubMed

    Yang, Bingcheng; Zhang, Min; Kanyanee, Tinakorn; Stamos, Brian N; Dasgupta, Purnendu K

    2014-12-01

    We describe an open tubular ion chromatograph (OTIC) that uses anion exchange latex coated 5 μm radius silica and 9.8 μm radius poly(methyl methacrylate) tubes and automated time/pressure based hydrodynamic injection for pL-nL scale injections. It is routinely possible to generate 50,000 plates or more (up to 150,000 plates/m, columns between 0.3 and 0.8 m have been used), and as such, fast separations are possible, comparable to or in some cases better than the current practice of IC. With an optimized admittance detector, nonsuppressed detection permits LODs of submicromolar to double digit micromolar for a variety of analytes. However, large volume injections are possible and can significantly improve on this. A variety of eluents, the use of organic modifiers, and variations of eluent pH can be used to tailor a given separation. The approach is discussed in the context of extraterrestrial exploration, especially Mars, where the existence of large amounts of perchlorate in the soil needs to be confirmed. These columns can survive drying and freezing, and small footprint, low power consumption, and simplicity make OTIC a good candidate for such a mission. PMID:25394230

  19. Hand-held multiple system gas chromatograph

    DOEpatents

    Yu, Conrad M.

    2001-01-01

    A multiple parallel hand-held gas chromatograph (GC) system which includes several independent GCs. Each independent GC has its own injector, separation column, detector and oven and the GCs are mounted in a light weight hand-held assembly. Each GC operates independently and simultaneously. Because of different coatings in different separation columns, different retention times for the same gas will be measured. Thus, for a GC system with multiple parallel GCs, the system can measure, in a short period, different retention times and provide a cross-reference in the determination of the measured gas and to become a two-dimensional system for direct field use.

  20. Identification of homemade inorganic explosives by ion chromatographic analysis of post-blast residues.

    PubMed

    Johns, Cameron; Shellie, Robert A; Potter, Oscar G; O'Reilly, John W; Hutchinson, Joseph P; Guijt, Rosanne M; Breadmore, Michael C; Hilder, Emily F; Dicinoski, Greg W; Haddad, Paul R

    2008-02-29

    Anions and cations of interest for the post-blast identification of homemade inorganic explosives were separated and detected by ion chromatographic (IC) methods. The ionic analytes used for identification of explosives in this study comprised 18 anions (acetate, benzoate, bromate, carbonate, chlorate, chloride, chlorite, chromate, cyanate, fluoride, formate, nitrate, nitrite, perchlorate, phosphate, sulfate, thiocyanate and thiosulfate) and 12 cations (ammonium, barium(II), calcium(II), chromium(III), ethylammonium, magnesium(II), manganese(II), methylammonium, potassium(I), sodium(I), strontium(II), and zinc(II)). Two IC separations are presented, using suppressed IC on a Dionex AS20 column with potassium hydroxide as eluent for anions, and non-suppressed IC for cations using a Dionex SCS 1 column with oxalic acid/acetonitrile as eluent. Conductivity detection was used in both cases. Detection limits for anions were in the range 2-27.4ppb, and for cations were in the range 13-115ppb. These methods allowed the explosive residue ions to be identified and separated from background ions likely to be present in the environment. Linearity (over a calibration range of 0.05-50ppm) was evaluated for both methods, with r(2) values ranging from 0.9889 to 1.000. Reproducibility over 10 consecutive injections of a 5ppm standard ranged from 0.01 to 0.22% relative standard deviation (RSD) for retention time and 0.29 to 2.16%RSD for peak area. The anion and cation separations were performed simultaneously by using two Dionex ICS-2000 chromatographs served by a single autoinjector. The efficacy of the developed methods was demonstrated by analysis of residue samples taken from witness plates and soils collected following the controlled detonation of a series of different inorganic homemade explosives. The results obtained were also confirmed by parallel analysis of the same samples by capillary electrophoresis (CE) with excellent agreement being obtained. PMID:18221942

  1. Chromatographic Purification of Highly Active Yeast Ribosomes

    PubMed Central

    Meskauskas, Arturas; Leshin, Jonathan A.; Dinman, Jonathan D.

    2011-01-01

    Eukaryotic ribosomes are much more labile as compared to their eubacterial and archael counterparts, thus posing a significant challenge to researchers. Particularly troublesome is the fact that lysis of cells releases a large number of proteases and nucleases which can degrade ribosomes. Thus, it is important to separate ribosomes from these enzymes as quickly as possible. Unfortunately, conventional differential ultracentrifugation methods leaves ribosomes exposed to these enzymes for unacceptably long periods of time, impacting their structural integrity and functionality. To address this problem, we utilize a chromatographic method using a cysteine charged Sulfolink resin. This simple and rapid application significantly reduces co-purifying proteolytic and nucleolytic activities, producing high yields of intact, highly biochemically active yeast ribosomes. We suggest that this method should also be applicable to mammalian ribosomes. The simplicity of the method, and the enhanced purity and activity of chromatographically purified ribosome represents a significant technical advancement for the study of eukaryotic ribosomes. PMID:22042245

  2. Microfabricated packed gas chromatographic column

    DOEpatents

    Kottenstette, Richard; Matzke, Carolyn M.; Frye-Mason, Gregory C.

    2003-12-16

    A new class of miniaturized gas chromatographic columns has been invented. These chromatographic columns are formed using conventional micromachining techniques, and allow packed columns having lengths on the order of a meter to be fabricated with a footprint on the order of a square centimeter.

  3. Analysis of Veterinary Drug and Pesticide Residues Using the Ethyl Acetate Multiclass/Multiresidue Method in Milk by Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Imamoglu, Husniye; Oktem Olgun, Elmas

    2016-01-01

    A rapid and simple multiclass, ethyl acetate (EtOAc) multiresidue method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) detection was developed for the determination and quantification of 26 veterinary drugs and 187 total pesticide residues in milk. Sample preparation was a simple procedure based on liquid–liquid extraction with ethyl acetate containing 0.1% acetic acid, followed by centrifugation and evaporation of the supernatant. The residue was dissolved in ethyl acetate with 0.1% acetic acid and centrifuged prior to LC-MS/MS analysis. Chromatographic separation of analytes was performed on an Inertsil X-Terra C18 column with acetic acid in methanol and water gradient. The repeatability and reproducibility were in the range of 2 to 13% and 6 to 16%, respectively. The average recoveries ranged from 75 to 120% with the RSD (n = 18). The developed method was validated according to the criteria set in Commission Decision 2002/657/EC and SANTE/11945/2015. The validated methodology represents a fast and cheap alternative for the simultaneous analysis of veterinary drug and pesticide residues which can be easily extended to other compounds and matrices. PMID:27293962

  4. Analysis of Veterinary Drug and Pesticide Residues Using the Ethyl Acetate Multiclass/Multiresidue Method in Milk by Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Imamoglu, Husniye; Oktem Olgun, Elmas

    2016-01-01

    A rapid and simple multiclass, ethyl acetate (EtOAc) multiresidue method based on liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) detection was developed for the determination and quantification of 26 veterinary drugs and 187 total pesticide residues in milk. Sample preparation was a simple procedure based on liquid-liquid extraction with ethyl acetate containing 0.1% acetic acid, followed by centrifugation and evaporation of the supernatant. The residue was dissolved in ethyl acetate with 0.1% acetic acid and centrifuged prior to LC-MS/MS analysis. Chromatographic separation of analytes was performed on an Inertsil X-Terra C18 column with acetic acid in methanol and water gradient. The repeatability and reproducibility were in the range of 2 to 13% and 6 to 16%, respectively. The average recoveries ranged from 75 to 120% with the RSD (n = 18). The developed method was validated according to the criteria set in Commission Decision 2002/657/EC and SANTE/11945/2015. The validated methodology represents a fast and cheap alternative for the simultaneous analysis of veterinary drug and pesticide residues which can be easily extended to other compounds and matrices. PMID:27293962

  5. Quantitative analysis and purity evaluation of medroxyprogesterone acetate by HPLC.

    PubMed

    Cavina, G; Valvo, L; Alimenti, R

    1985-01-01

    A reversed-phase high-performance liquid chromatographic method was developed for the assay of medroxyprogesterone acetate and for the detection and determination of related steroids present as impurities in the drug. The method was compared with the normal-phase technique of the USP XX and was also applied to the analysis of tablets and injectable suspensions. PMID:16867645

  6. Simultaneous liquid-chromatographic determination of vitamin K1 and vitamin E in serum.

    PubMed

    Cham, B E; Roeser, H P; Kamst, T W

    1989-12-01

    We describe a high-performance liquid chromatographic procedure for the simultaneous measurement of vitamins K1 and E in human serum. Delipidated human serum (free of vitamins K1 and E) was used to make standard solutions of these vitamins, and cetyl naphthoate and alpha-tocopheryl acetate were the internal standards for vitamin K1 and vitamin E, respectively. A simple, novel separation method utilizing liquid-liquid partition chromatography was used as a preparative "clean-up" procedure. Cetyl naphthoate and vitamin K1 (after post-column reduction) were detected by fluorescence, alpha-tocopheryl acetate and vitamin E by ultraviolet absorption. Sensitivity (detection limit) of the assay was 30 pg for vitamin K1 and 5 ng for vitamin E per injection. The method is specific, precise, and more rapid than previously described procedures. Within- and between-assay CVs were 8.1% and 12.9%, respectively, for vitamin K1; 3.5% and 6.0%, respectively, for vitamin E. Analytical recoveries of vitamins K1 and E were 80% and 93%, respectively, from serum and from delipidated serum (standards). The average neonatal serum concentration of vitamin K1 was 83 ng/L, 2.5 mg/L for vitamin E; for normolipidemic adults, the values were 343 ng/L and 7.9 mg/L, respectively, and for hyperlipidemic adults, 541 ng/L and 11.1 mg/L, respectively. PMID:2591045

  7. Application of Analytical Quality by Design concept for bilastine and its degradation impurities determination by hydrophilic interaction liquid chromatographic method.

    PubMed

    Terzić, Jelena; Popović, Igor; Stajić, Ana; Tumpa, Anja; Jančić-Stojanović, Biljana

    2016-06-01

    This paper deals with the development of hydrophilic interaction liquid chromatographic (HILIC) method for the analysis of bilastine and its degradation impurities following Analytical Quality by Design approach. It is the first time that the method for bilastine and its impurities is proposed. The main objective was to identify the conditions where an adequate separation in minimal analysis duration could be achieved within a robust region. Critical process parameters which have the most influence on method performance were defined as acetonitrile content in the mobile phase, pH of the aqueous phase and ammonium acetate concentration in the aqueous phase. Box-Behnken design was applied for establishing a relationship between critical process parameters and critical quality attributes. The defined mathematical models and Monte Carlo simulations were used to identify the design space. Fractional factorial design was applied for experimental robustness testing and the method is validated to verify the adequacy of selected optimal conditions: the analytical column Luna(®) HILIC (100mm×4.6mm, 5μm particle size); mobile phase consisted of acetonitrile-aqueous phase (50mM ammonium acetate, pH adjusted to 5.3 with glacial acetic acid) (90.5:9.5, v/v); column temperature 30°C, mobile phase flow rate 1mLmin(-1), wavelength of detection 275nm. PMID:27131148

  8. Column performance study of different variants of liquid chromatographic technique: an application on pharmaceutical ternary mixtures containing tetryzoline.

    PubMed

    Salem, Hesham; Hassan, Nagiba Y; Lotfy, Hayam M; Saleh, Sarah S

    2015-01-01

    High-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and rapid resolution liquid chromatographic (RRLC) methods have been developed and validated for the separation and quantitation of both or either of two ternary mixtures present in ophthalmic solutions. The first mixture contains chloramphenicol, dexamethasone sodium phosphate and tetryzoline HCl (TZH); while the second one contains ofloxacin, prednisolone acetate and TZH. Both preparations contain benzalkonium chloride as a preservative. The columns used were a HPLC column (C18 5 µm particle size), a RRLC column (C18 2.6 µm particle size) and a UPLC column (C18 1.7 µm particle size). A comparative study was conducted to illustrate the effect of the change in column particle size and dimensions on the other chromatographic conditions, backpressure and the separation of both ternary mixtures. The methods were validated as per ICH guidelines where accuracy, repeatability, interday precision and robustness were found to be within the acceptable limits. The RRLC column provided shorter run time and better resolution than HPLC, while the UPLC column gave the shortest run time for all columns. The RRLC column resulted in minimum backpressure, so it could be used with any HPLC instrument, which makes the method more practical and economic. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed. PMID:25217705

  9. EVALUATION OF PORTABLE GAS CHROMATOGRAPHS

    EPA Science Inventory

    Limits of detection, linearity of responses, and stability of response factors and retention times for five commercially-available portable gas chromatographs (PGC) were determined during laboratory evaluation. he PGCs were also operated at the French Limited Superfund site near ...

  10. Development and Validation of an RP-HPLC Method for Quantitative Estimation of Eslicarbazepine Acetate in Bulk Drug and Tablets

    PubMed Central

    Singh, M.; Kumar, L.; Arora, P.; Mathur, S. C.; Saini, P. K.; Singh, R. M.; Singh, G. N.

    2013-01-01

    A convenient, simple, accurate, precise and reproducible RP-HPLC method was developed and validated for the estimation of eslicarbazepine acetate in bulk drug and tablet dosage form. Objective was achieved under optimised chromatographic conditions on Dionex RP-HPLC system with Dionex C18 column (250×4.6 mm, 5 μm particle size) using mobile phase composed of methanol and ammonium acetate (0.005 M) in the ratio of 70:30 v/v. The separation was achieved using an isocratic elution method with a flow rate of 1.0 ml/ min at room temperature. The effluent was monitored at 230 nm using diode array detector. The retention time of eslicarbazepine acetate is found to be 4.9 min and the standard calibration plot was linear over a concentration range of 10-90 μg/ml with r2=0.9995. The limit of detection and quantification were found to be 3.144 and 9.52 μg/ml, respectively. The amount of eslicarbazepine acetate in bulk and tablet dosage form was found to be 99.19 and 97.88%, respectively. The method was validated statistically using the percent relative standard deviation and the values are found to be within the limits. The recovery studies were performed and the percentage recoveries were found to be 98.33± 0.5%. PMID:24591752

  11. Development and Validation of an RP-HPLC Method for Quantitative Estimation of Eslicarbazepine Acetate in Bulk Drug and Tablets.

    PubMed

    Singh, M; Kumar, L; Arora, P; Mathur, S C; Saini, P K; Singh, R M; Singh, G N

    2013-11-01

    A convenient, simple, accurate, precise and reproducible RP-HPLC method was developed and validated for the estimation of eslicarbazepine acetate in bulk drug and tablet dosage form. Objective was achieved under optimised chromatographic conditions on Dionex RP-HPLC system with Dionex C18 column (250×4.6 mm, 5 μm particle size) using mobile phase composed of methanol and ammonium acetate (0.005 M) in the ratio of 70:30 v/v. The separation was achieved using an isocratic elution method with a flow rate of 1.0 ml/ min at room temperature. The effluent was monitored at 230 nm using diode array detector. The retention time of eslicarbazepine acetate is found to be 4.9 min and the standard calibration plot was linear over a concentration range of 10-90 μg/ml with r(2)=0.9995. The limit of detection and quantification were found to be 3.144 and 9.52 μg/ml, respectively. The amount of eslicarbazepine acetate in bulk and tablet dosage form was found to be 99.19 and 97.88%, respectively. The method was validated statistically using the percent relative standard deviation and the values are found to be within the limits. The recovery studies were performed and the percentage recoveries were found to be 98.33± 0.5%. PMID:24591752

  12. Gas chromatograph-mass spectrometer (GC/MS) system for quantitative analysis of reactive chemical compounds

    DOEpatents

    Grindstaff, Quirinus G.

    1992-01-01

    Described is a new gas chromatograph-mass spectrometer (GC/MS) system and method for quantitative analysis of reactive chemical compounds. All components of such a GC/MS system external to the oven of the gas chromatograph are programmably temperature controlled to operate at a volatilization temperature specific to the compound(s) sought to be separated and measured.

  13. Rayleigh light scattering detection of three α1-adrenoceptor antagonists coupled with high performance liquid chromatograph

    NASA Astrophysics Data System (ADS)

    Li, Ai Ping; Peng, Huanjun; Peng, Jing Dong; Zhou, Ming Qiong; Zhang, Jing

    2015-08-01

    Herein, a Rayleigh light-scattering (RLS) detection method combined with high performance liquid chromatograph (HPLC) without any post-column probe was developed for the separation and determination of three α1-adrenoceptor antagonists. The quantitative analysis is benefiting from RLS signal enhancement upon addition of methanol which induced molecular aggregation to form an hydrophobic interface between aggregates and water that produce a sort of superficial enhanced scattering effect. A good chromatographic separation among the compounds was achieved using a Gemini 5u C18 reversed phase column (250 mm × 4.6 mm; 4 μm) with a mobile phase consisting of methanol and ammonium acetate-formic acid buffer solution (25 mM; pH = 3.0) at the flow rate of 0.7 mL min-1. The RLS signal was monitored at λex = λem = 354 nm. A limit of detection (LOD) of 0.065-0.70 μg L-1 was reached and a linear range was found between peak height and concentration in the range of 0.75-15 μg L-1 for doxazosin mesylate (DOX), 0.075-3.0 μg L-1 for prazosin hydrochloride (PRH), and 0.25-5 μg L-1 for terazosin hydrochloride (TEH), with linear regression coefficients all above 0.999. Recoveries from spiked urine samples were 88.4-99.0% which is within acceptable limits. The proposed method is convenient, reliable and sensitive which has been used successfully in human urine samples.

  14. Nanofluidic Size-Exclusion Chromatograph

    NASA Technical Reports Server (NTRS)

    Feldman, Sabrina; Svehla, Danielle; Grunthaner, Frank; Feldman, Jason; Shakkottai, P.

    2004-01-01

    Efforts are under way to develop a nanofluidic size-exclusion chromatograph (SEC), which would be a compact, robust, lightweight instrument for separating molecules of interest according to their sizes and measuring their relative abundances in small samples. About as large as a deck of playing cards, the nanofluidic SEC would serve, in effect, as a laboratory on a chip that would perform the functions of a much larger, conventional, bench-top SEC and ancillary equipment, while consuming much less power and much smaller quantities of reagent and sample materials. Its compactness and low power demand would render it attractive for field applications in which, typically, it would be used to identify and quantitate a broad range of polar and nonpolar organic compounds in soil, ice, and water samples. Size-exclusion chromatography is a special case of high-performance liquid chromatography. In a conventional SEC, a sample plug is driven by pressure along a column packed with silica or polymer beads that contain uniform nanopores. The interstices between, and the pores in, the beads collectively constitute a size-exclusion network. Molecules follow different paths through the size-exclusion network, such that characteristic elution times can be related to sizes of molecules: basically, smaller molecules reach the downstream end of the column after the larger ones do because the smaller ones enter minor pores and stay there for a while, whereas the larger ones do not enter the pores. The volume accessible to molecules gradually diminishes as their size increases. All molecules bigger than a pore size elute together. For most substances, the elution times and sizes of molecules can be correlated directly with molecular weights. Hence, by measuring the flux of molecules arriving at the downstream end as a function of time, one can obtain a liquid mass spectrum for the molecules present in a sample over a broad range of molecular weights.

  15. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory. 17 references, 9 figures, 1 table.

  16. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everywhere else around the annulus. The rotation of the sorbent bed causes the separated components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory. 9 figures, 1 table.

  17. High-capacity pressurized continuous chromatograph

    SciTech Connect

    Begovich, J.M.; Byers, C.H.; Sisson, W.G.

    1983-01-01

    Multicomponent liquid chromatographic separations have been achieved by using a slowly rotating annular bed of sorbent material. The feed material is continuously introduced at a stationary point at the top of the bed, and eluent is allowed to flow everwhere else around the annulus. The rotation of the sorbent bed causes the separation components to appear as helical bands, each of which has a characteristic, stationary exit point; hence the separation process is truly continuous. The concept has been developed primarily on a 279-mm-diam by 0.6-m-long device with a 12.7-mm-wide annulus. The effects of annulus width and diameter have been studied using the same device with annulus widths up to 114.3 mm. With this largest width, approximately 96% of the area available within the outer cylinder is devoted to the rotating sorbent bed. Further annulus-width studies have been pursued on units with 89- and 445-mm diameters. These geometric extensions to the basic concept allow extremely large capacity increases with minimal loss in separation and no increase in chromatograph diameter. The effects associated with increased feed concentration have also been studied. In this effort as well as in the annulus-width program, the separation of copper, nickel, and cobalt components from a carbonate solution was studied in detail. The nickel and cobalt components are found in the leach liquor of the Caron process for recovering nickel and cobalt from laterite ores. Nominally 50-..mu..m0-diam Dowex 50W-X8 cation exchange resin was used as the bed material. The nickel concentration of the feed was varied tenfold, from 136.1 to approximately 1400 meq/L. The combined effects of the bed loading and annulus width were studied and compared with nonlinear theory.

  18. High performance hand-held gas chromatograph

    SciTech Connect

    Yu, C.M.

    1998-04-28

    The Microtechnology Center of Lawrence Livermore National Laboratory has developed a high performance hand-held, real time detection gas chromatograph (HHGC) by Micro-Electro-Mechanical-System (MEMS) technology. The total weight of this hand-held gas chromatograph is about five lbs., with a physical size of 8{close_quotes} x 5{close_quotes} x 3{close_quotes} including carrier gas and battery. It consumes about 12 watts of electrical power with a response time on the order of one to two minutes. This HHGC has an average effective theoretical plate of about 40k. Presently, its sensitivity is limited by its thermal sensitive detector at PPM. Like a conventional G.C., this HHGC consists mainly of three major components: (1) the sample injector, (2) the column, and (3) the detector with related electronics. The present HHGC injector is a modified version of the conventional injector. Its separation column is fabricated completely on silicon wafers by means of MEMS technology. This separation column has a circular cross section with a diameter of 100 pm. The detector developed for this hand-held GC is a thermal conductivity detector fabricated on a silicon nitride window by MEMS technology. A normal Wheatstone bridge is used. The signal is fed into a PC and displayed through LabView software.

  19. Reactor-chromatographic determination of vinyl chloride in polyvinyl chloride

    SciTech Connect

    Berezkin, V.G.

    1986-08-01

    The authors carry out a chromatographic study of the volatile products that evolve when various grades of domestic polyvinyl chloride are heated, to determine the concentration of residual monomer. To find vinyl chloride in complex mixtures of air pollutants the authors used sorptive reaction concentration of impurities. This new combination of methods is based on preliminary separation at the sampling stage of impurities that interfere in the analysis, followed by concentration of the desired components in a trap with an adsorbent, and chromatographic determination of the concentrated trace materials. The method obtains low vinyl chloride concentrations (down to 10/sup -4/-10/sup -5/ wt. %) with +/-5 relative error.

  20. Gas-liquid chromatographic determination of morphine, heroin, and cocaine.

    PubMed

    Prager, M J; Harrington, S M; Governo, T F

    1979-03-01

    Morphine, heroin, and cocaine are quantitatively determined with the same gas-liquid chromatographic system. The compounds are separated on a 6 ft X 2 mm id glass column packed with a 1:1 mixture of 5% SE-30 on 80--100 mesh Chromosorb W and 3% OV-17 on 80--100 mesh Varaport 30. The column is temperature-programmed. Flame ionization detector responses are measured with a computer-based data system. Heroin and cocaine are chromatographed directly; morphine is derivatized first. The procedure was evaluated with previously analyzed commercial and forensic samples. Accuracy and precision were 5 and 3%, respectively. PMID:447602

  1. Derivatization and gas chromatographic-mass spectrometric detection of anabolic steroid residues isolated from edible muscle tissues.

    PubMed

    Daeseleire, E; De Guesquière, A; Van Peteghem, C

    1991-01-01

    A method was developed for the detection of anabolic steroid residues in edible muscle tissues. After enzymic digestion of the tissue and purification on disposable C18 solid-phase extraction columns, the extract was injected onto a C18 reversed-phase high-performance liquid chromatographic column. Three fractions or windows were collected, each containing specific analytes. After evaporation to dryness, the residues were subjected to a derivatization procedure which yielded suitable derivatives. After gas chromatographic-mass spectrometric analysis, both gas chromatographic retention data and mass spectral data were used for the detection and identification of nortestosterone, testosterone, estradiol, ethinylestradiol, trenbolone, methyltestosterone, chlormadinone acetate, medroxyprogesterone acetate and megestrol acetate. PMID:2026730

  2. High-pressure liquid chromatographic method for the determination of patulin in apple butter.

    PubMed

    Ware, G M

    1975-07-01

    Patulin is extracted from apple butter samples with ethyl acetate and the extract is cleaned up on a silica gel column, using benzene-ethyl acetate (75+25) as the eluant. High-pressure liquid chromatography, using a 25 cm ZorbaxSil column, isooctane-ethyl ether-acetic acid (750+250+0.5) as the mobile solvent, and a 254 nm ultraviolet detector, is used for the determinative step. Under these conditions, patulin is eluted before 5-hydroxymethylfurfural, a component of apple butter which interferes with other liquid chromatographic and thin layer chromatographic methods. Recoveries of patulin added at levels of 34.6, 138.4, and 276.8 mug/kg ranged from 89.0 to 112.1%. PMID:168176

  3. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, Don D.

    1985-01-01

    A chromatographic system that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a non-transparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extremely low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  4. Dual liquid and gas chromatograph system

    DOEpatents

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  5. Selective and sensitive liquid chromatographic determination method of 5-hydroxyindoles with fluorous and fluorogenic derivatization.

    PubMed

    Sakaguchi, Yohei; Ikenaga, Jun; Yoshida, Hideyuki; Hayama, Tadashi; Itoyama, Miki; Todoroki, Kenichiro; Imakyure, Osamu; Yamaguchi, Masatoshi; Nohta, Hitoshi

    2015-10-10

    A liquid chromatographic (LC) method with improved selectivity for the simultaneous determination of 5-hydroxyindoles (5-HIs; 5-hydroxytryptophan, 5-hydroxytryptamine, N-acetyl-5-hydroxytryptamine, 5-hydroxyindole-3-acetic acid, and 5-hydroxytryptophol) is described. This method involves precolumn derivatization with 4-(3',3',4',4',5',5',6',6',7',7',8',8',9',9',10',10',10'-heptadecafluorodecyl)benzylamine (HFBA) and separation of the derivatives using a fluorous LC column. In this study, stable benzoxazole derivatives of 5-HIs with HFBA have been obtained by a simple derivatization procedure; their fluorescent properties enabled highly sensitive detection. In addition, only the HFBA derivatives of 5-HIs has been selectively retained on the fluorous LC column via fluorous interaction whereby perfluoroalkyl compounds show affinities with each other, while the non-fluorous compounds did not. The HFBA derivatives were separated within 30 min and the detection limits for 5-HIs in a 20-μL injection volume were 1.2-14 fmol (S/N=3). Furthermore, this method was applied to the analysis of 5-HIs in the human plasma from healthy subjects. PMID:26112924

  6. DEVELOPMENT AND VALIDATION OF AN ION CHROMATOGRAPHIC METHOD FOR DETERMINING PERCHLORATE IN FERTILIZERS

    EPA Science Inventory

    A method has been developed for the determination of perchlorate in fertilizers. Materials are leached with deionized water to dissolve any soluble perchlorate compounds. Ion chromatographic separation is followed by suppressed conductivity for detection. Perchlorate is retained ...

  7. GAS CHROMATOGRAPH-BASED SYSTEM FOR MEASURING THE METHANE FRACTION OF DIESEL ENGINE HYDROCARBON EMISSIONS

    EPA Science Inventory

    An instrument has been developed (termed the 'methane analytical system') enabling diesel methane emissions to be quatified separately from total unburned hydrocarbon emissions. The instrument employed gas chromatographic principles whereby a molecular sieve column operating isot...

  8. Chromatographic behaviors of proteins on cation-exchange column.

    PubMed

    Li, Rong; Chen, Guo-Liang; Zhao, Wen-Ming

    2004-12-01

    A weak cation-exchanger (XIDACE-WCX) has been synthesized by the indirect method. The chromatographic characteristics of the synthesized packing was studied in detail. The standard protein mixture and lysozyme from egg white were separated with the prepared chromatographic column. The chromatographic thermodynamics of proteins was studied in a wide temperature range. Thermodynamic parameters standard enthalpy change (deltaH0) and standard entropy change (deltaS0) and compensation temperature (beta) at protein denaturation were determined in the chromatographic system. By using obtained deltaS0, the conformational change of proteins was judged in the chromatographic process. The linear relationship between deltaH0 and deltaS0 can be used to identify the identity of the protein retention mechanism in the weak cation-exchange chromatography. The interaction between weak cation-exchanger and metal ions was investigated. Several metal chelate columns were prepared. The effects of introducing metal ion into the naked column on protein retention and the retention mechanism of proteins in the metal chalet affinity chromatography were discussed. PMID:15689030

  9. Chromatographic extraction with di(2-ethylhexyl)orthophosphoric acid for production and purification of promethium-147

    DOEpatents

    Boll, Rose A [Knoxville, TN

    2008-10-14

    A method of producing and purifying promethium-147 including the steps of: irradiating a target material including neodymium-146 with neutrons to produce promethium-147 within the irradiated target material; dissolving the irradiated target material to form an acidic solution; loading the acidic solution onto a chromatographic separation apparatus containing HDEHP; and eluting the apparatus to chromatographically separate the promethium-147 from the neodymium-146.

  10. Validated chromatographic methods for determination of perindopril and amlodipine in pharmaceutical formulation in the presence of their degradation products.

    PubMed

    Zaazaa, Hala E; Abbas, Samah S; Essam, Hebat Allah M; El-Bardicy, Mohammed G

    2013-07-01

    Two specific, sensitive, and precise stability-indicating chromatographic methods have been developed, optimized and validated for determination of perindopril arginin (PER) and amlodipine besylate (AML) in their mixtures and in the presence of their degradation products. The first method was based on thin-layer chromatography (TLC) combined with densitometric determination of the separated bands. Adequate separation was achieved using silica gel 60 F254 TLC plates and ethyl acetate-methanol-toluene-ammonia solution, 33% (6.5:2:1:0.5 by volume), as a developing system. The second method was based on high-performance liquid chromatography, by which the proposed components were separated on a reversed-phase C18 analytical column using a mobile phase consisting of phosphate buffer (pH 2.5, 0.01 M)-acetonitrile-tetrahydrofuran (60:40:0.1% by volume) with ultraviolet detection at 218 nm. Different parameters affecting the suggested methods were optimized for maximum separation of the cited components. System suitability parameters of the two developed methods were also tested. The suggested methods were validated in compliance with the ICH guidelines and were successfully applied for the quantification of PER and AML in their commercial tablets. Both methods were also statistically compared to each other and to the reference methods with no significant differences in performance. PMID:23112269

  11. Fast chromatographic method for the determination of dyes in beverages by using high performance liquid chromatography--diode array detection data and second order algorithms.

    PubMed

    Culzoni, María J; Schenone, Agustina V; Llamas, Natalia E; Garrido, Mariano; Di Nezio, Maria S; Band, Beatriz S Fernández; Goicoechea, Héctor C

    2009-10-16

    A fast chromatographic methodology is presented for the analysis of three synthetic dyes in non-alcoholic beverages: amaranth (E123), sunset yellow FCF (E110) and tartrazine (E102). Seven soft drinks (purchased from a local supermarket) were homogenized, filtered and injected into the chromatographic system. Second order data were obtained by a rapid LC separation and DAD detection. A comparative study of the performance of two second order algorithms (MCR-ALS and U-PLS/RBL) applied to model the data, is presented. Interestingly, the data present time shift between different chromatograms and cannot be conveniently corrected to determine the above-mentioned dyes in beverage samples. This fact originates the lack of trilinearity that cannot be conveniently pre-processed and can hardly be modelled by using U-PLS/RBL algorithm. On the contrary, MCR-ALS has shown to be an excellent tool for modelling this kind of data allowing to reach acceptable figures of merit. Recovery values ranged between 97% and 105% when analyzing artificial and real samples were indicative of the good performance of the method. In contrast with the complete separation, which consumes 10 mL of methanol and 3 mL of 0.08 mol L(-1) ammonium acetate, the proposed fast chromatography method requires only 0.46 mL of methanol and 1.54 mL of 0.08 mol L(-1) ammonium acetate. Consequently, analysis time could be reduced up to 14.2% of the necessary time to perform the complete separation allowing saving both solvents and time, which are related to a reduction of both the costs per analysis and environmental impact. PMID:19748097

  12. Bk and Cf chromatographic separation and ²⁴⁹Bk/²⁴⁸Cm and ²⁴⁹Cf/²⁴⁸Cm elemental ratios determination by inductively coupled plasma quadrupole mass spectrometry.

    PubMed

    Gourgiotis, A; Isnard, H; Nonell, A; Aubert, M; Stadelmann, G; Dupont, E; AlMahamid, I; Tiang, G; Rao, L; Lukens, W; Cassette, P; Panebianco, S; Letourneau, A; Chartier, F

    2013-03-15

    The French Atomic Energy Commission has carried out several experiments for the study of minor-actinide transmutation processes in high intensity thermal neutron flux. In this context a Cm sample enriched in (248)Cm (∼97%) was irradiated in a thermal neutron flux at the High Flux Reactor (HFR) of the Laue-Langevin Institute (ILL). The precise and accurate determination of Cf isotope ratios and of (249)Bk/(248)Cm and (249)Cf/(248)Cm elemental ratios in the (248)Cm irradiated sample is crucial for the calculation of actinide neutron capture cross-sections. This work describes an analytical procedure for the separation and the isotope ratio measurement of Bk and Cf in the irradiated sample. The Bk and Cf separation is based on a lanthanides separation protocol previously developed by the laboratory. Well-defined retention times for Bk and Cf were obtained by coupling the Ionic Chromatography (IC) with an ICP-QMS. All conditions of element separation by IC and the different steps of the analytical protocol in order to obtain the isotopic and elemental ratios are presented. Relative uncertainties of Cf isotopic ratios range from 0.3% to 0.5% and the uncertainty of the (249)Bk/(248)Cm and (249)Cf/(248)Cm elemental ratios are respectively 6.1% and 3.2%. This level of uncertainty for both isotopic and elemental ratios is in perfect agreement with the requirement for transmutation studies. PMID:23598093

  13. Expression of acetate permease-like (apl) genes in subsurface communities of Geobacter species under fluctuating acetate concentrations

    SciTech Connect

    Elifantz, H.; N'Guessan, L.A.; Mouser, P.J.; Williams, K H.; Wilkins, M J.; Risso, C.; Holmes, D.E.; Long, P.E.; Lovley, D.R.

    2010-03-01

    The addition of acetate to uranium-contaminated aquifers in order to stimulate the growth and activity of Geobacter species that reduce uranium is a promising in situ bioremediation option. Optimizing this bioremediation strategy requires that sufficient acetate be added to promote Geobacter species growth. We hypothesized that under acetate-limiting conditions, subsurface Geobacter species would increase the expression of either putative acetate symporters genes (aplI and aplII). Acetate was added to a uranium-contaminated aquifer (Rifle, CO) in two continuous amendments separated by 5 days of groundwater flush to create changing acetate concentrations. While the expression of aplI in monitoring well D04 (high acetate) weakly correlated with the acetate concentration over time, the transcript levels for this gene were relatively constant in well D08 (low acetate). At the lowest acetate concentrations during the groundwater flush, the transcript levels of aplII were the highest. The expression of aplII decreased 2-10-fold upon acetate reintroduction. However, the overall instability of acetate concentrations throughout the experiment could not support a robust conclusion regarding the role of apl genes in response to acetate limitation under field conditions, in contrast to previous chemostat studies, suggesting that the function of a microbial community cannot be inferred based on lab experiments alone.

  14. Expression of Acetate Permease-like (apl) Genes in Subsurface Communities of Geobacter Species Under Fluctuating Acetate Concentrations

    SciTech Connect

    Elifantz, H; N'Guessan, A L; Mouser, Paula; Williams, Kenneth H; Wilkins, Michael J; Risso, Carla; Holmes, Dawn; Long, Philip E; Lovley, Derek R

    2010-09-01

    The addition of acetate to uranium-contaminated aquifers in order to stimulate the growth and activity of Geobacter species that reduce uranium is a promising in situ bioremediation option. Optimizing this bioremediation strategy requires that sufficient acetate be added to promote Geobacter species growth. We hypothesized that under acetate-limiting conditions, subsurface Geobacter species would increase the expression of either putative acetate symporters genes (aplI and aplII). Acetate was added to a uranium-contaminated aquifer (Rifle, CO) in two continuous amendments separated by 5 days of groundwater flush to create changing acetate concentrations. While the expression of aplI in monitoring well D04 (high acetate) weakly correlated with the acetate concentration over time, the transcript levels for this gene were relatively constant in well D08 (low acetate). At the lowest acetate concentrations during the groundwater flush, the transcript levels of aplII were the highest. The expression of aplII decreased 2–10-fold upon acetate reintroduction. However, the overall instability of acetate concentrations throughout the experiment could not support a robust conclusion regarding the role of apl genes in response to acetate limitation under field conditions, in contrast to previous chemostat studies, suggesting that the function of a microbial community cannot be inferred based on lab experiments alone.

  15. Quality by Design approach in the development of hydrophilic interaction liquid chromatographic method for the analysis of iohexol and its impurities.

    PubMed

    Jovanović, Marko; Rakić, Tijana; Tumpa, Anja; Jančić Stojanović, Biljana

    2015-06-10

    This study presents the development of hydrophilic interaction liquid chromatographic method for the analysis of iohexol, its endo-isomer and three impurities following Quality by Design (QbD) approach. The main objective of the method was to identify the conditions where adequate separation quality in minimal analysis duration could be achieved within a robust region that guarantees the stability of method performance. The relationship between critical process parameters (acetonitrile content in the mobile phase, pH of the water phase and ammonium acetate concentration in the water phase) and critical quality attributes is created applying design of experiments methodology. The defined mathematical models and Monte Carlo simulation are used to evaluate the risk of uncertainty in models prediction and incertitude in adjusting the process parameters and to identify the design space. The borders of the design space are experimentally verified and confirmed that the quality of the method is preserved in this region. Moreover, Plackett-Burman design is applied for experimental robustness testing and method is fully validated to verify the adequacy of selected optimal conditions: the analytical column ZIC HILIC (100 mm × 4.6 mm, 5 μm particle size); mobile phase consisted of acetonitrile-water phase (72 mM ammonium acetate, pH adjusted to 6.5 with glacial acetic acid) (86.7:13.3) v/v; column temperature 25 °C, mobile phase flow rate 1 mL min(-1), wavelength of detection 254 nm. PMID:25796982

  16. Preparation of vinyl acetate

    DOEpatents

    Tustin, Gerald Charles; Zoeller, Joseph Robert; Depew, Leslie Sharon

    1998-01-01

    This invention pertains to the preparation of vinyl acetate by contacting a mixture of hydrogen and ketene with a heterogeneous catalyst containing a transition metal to produce acetaldehyde, which is then reacted with ketene in the presence of an acid catalyst to produce vinyl acetate.

  17. Preparation of vinyl acetate

    DOEpatents

    Tustin, G.C.; Zoeller, J.R.; Depew, L.S.

    1998-03-24

    This invention pertains to the preparation of vinyl acetate by contacting a mixture of hydrogen and ketene with a heterogeneous catalyst containing a transition metal to produce acetaldehyde, which is then reacted with ketene in the presence of an acid catalyst to produce vinyl acetate.

  18. Chymopapain. Chromatographic purification and immunological characterization.

    PubMed

    Buttle, D J; Barrett, A J

    1984-10-01

    Chymopapain (EC 3.4.22.6) was purified from commercially available spray-dried latex of papaya (Carica papaya) fruit by (NH4)2SO4 fractionation and fast protein chromatography on the Mono S cation-exchange column. Multiple forms of chymopapain separated chromatographically were shown to be immunologically identical. A major form was isolated and found to be homogeneous by several criteria, and fully active, and its N-terminal amino acid was identified as tyrosine. Latex from fresh unripe papaya fruit contained predominantly one form of chymopapain, and it is concluded that chymopapain is a single enzyme distinct from the other cysteine proteinases of C. papaya latex. PMID:6437389

  19. A validated liquid chromatographic method for the determination of polycyclic aromatic hydrocarbons in honey after homogeneous liquid-liquid extraction using hydrophilic acetonitrile and sodium chloride as mass separating agent.

    PubMed

    Koltsakidou, Anastasia; Zacharis, Constantinos K; Fytianos, Konstantinos

    2015-01-16

    In the present report, a simple and cost-effective method for the determination of twelve US EPA priority polycyclic aromatic hydrocarbons (PAHs) in honey samples after salting-assisted liquid-liquid extraction and UHPLC with fluorescence detection is proposed. The sample treatment is based on the usage of hydrophilic acetonitrile as extraction solvent and its phase separation under high salinity conditions. Due to the high sugar content of the samples the phase separation is promoted effortlessly. Several parameters affecting the extraction efficiency and method sensitivity including the concentration of the honey samples, the type and volume of the extraction solvent, the type and quantity of the inorganic salt, extraction time and centrifugation time was systematically investigated. The method was validated in-house according to the Commission Decision 2002/657/EC guidelines. The limit of detection (LOD) of the method lay between 0.02 and 0.04ngmL(-1) (corresponding to 0.08 and 0.16ngg(-1)) which are close to the quality criteria established by European Regulation (EC) 836/2011 concerning the PAHs in foodstuffs. The mean analytical bias (expressed as relative recoveries) in all spiking levels was acceptable being in the range of 54-118% while the relative standard deviation (RSD) was lower than 19%. The proposed method has been satisfactorily applied for the analysis of the selected PAHs residues in various honey samples obtained from Greek region. PMID:25543304

  20. Rapid extraction and reverse phase-liquid chromatographic separation of mercury(II) and methylmercury in fish samples with inductively coupled plasma mass spectrometric detection applying oxygen addition into plasma.

    PubMed

    Döker, Serhat; Boşgelmez, İffet İpek

    2015-10-01

    A simple and sensitive procedure was developed for extraction and speciation of mercury in fish. Species separation was accomplished with reverse phase-high performance liquid chromatography (HPLC) hyphenated to inductively coupled plasma mass spectrometry (ICP-MS). Oxygen addition into plasma allowed use of organic-rich mobile phase, achieving species separation in 4 min. Mercury species extraction was achieved by microwave exposure for 2 min at mild conditions (60°C, pH 2.0), avoiding necessity of neutralizing sample prior to injection in HPLC, and reducing number of sample preparation steps, analytical source of errors and inter conversion of species. Limit of detection for entire procedure was found to be 0.2 and 0.1 ng g(-1) for mercuric ion and methylmercury, respectively. The method was applied to certified reference materials (TORT-2 and DORM-2) and commercialized fish samples (Mullus barbatus, Sparus aurata, Trachurus mediterraneus, Mugil soiuy, Dicentrarchus labrax, and Pomatomus saltatrix) from Black Sea. PMID:25872437

  1. Systematic Robustness Testing of a Liquid Chromatographic Method: A Case Study.

    PubMed

    Mannemala, Sai Sandeep; Kannappan, Valliappan

    2015-01-01

    Robustness testing of a method plays a crucial role in establishing its reliability. It examines the potential sources of variability in one or more responses of the proposed method. In this study, the robustness testing of a method proposed for simultaneous determination of warfarin and its two process related impurities was evaluated by using two level, fractional factorial design. Factors that are sensitive to a variation during method transfer were selected as independent variables [aqueous content (range: 39-43%, v/v), concentration of acetic acid (range: 0.08-0.12%, v/v), flow rate (range: 0.93-1.33 mL/min), and wavelength (range: 218-222 nm)]. Variables that determine the quality of separation, viz., retention factor of the first peak, resolution between the critical peak pair, tailing factor of warfarin, and total analysis time were selected as responses. Robustness was assessed by graphical (half normal probability and Pareto plots) and statistical (analysis of variance) methods. It was found that, among the studied variables, aqueous content had a significant effect on capacity factor and analysis time. Furthermore, non-significant intervals for significant factors were established by contour profiling. This study demonstrated the significance of experimental design and other statistical tools in understanding the effects of investigating factors of the chromatographic system and in defining their limits. PMID:26651591

  2. High Performance Liquid Chromatographic Analysis of Almotriptan Malate in Bulk and Tablets

    PubMed Central

    Lavudu, Petikam; Rani, Avula Prameela; Divya, Chepuri; Sekharan, Chandra Bala

    2013-01-01

    Purpose: A simple RP-HPLC method has been developed and validated for the determination of almotriptan malate (ATM) in bulk and tablets. Methods: Chromatographic separation of ATM was achieved by using a Thermo Scientific C18 column. A Mobile phase containing a mixture of methanol, water and acetic acid (4:8:0.1 v/v) was pumped at the flow rate of 1 mL/min. Detection was performed at 227 nm. According to ICH guidelines, the method was validated. Results: The calibration curve was linear in the concentration range 5–60 µg/mL for the ATM with regression coefficient 0.9999. The method was precise with RSD <1.2%. Excellent recoveries of 99.60 - 100.80% proved the accuracy of the method. The limits of detection and quantification were found to be 0.025 and 0.075 µg/mL, respectively. Conclusion: The method was successfully applied for the quantification of ATM in tablets with acceptable accuracy and precision. PMID:24312833

  3. Hydrophilic interaction chromatographic analysis of anthocyanins.

    PubMed

    Willemse, Chandré M; Stander, Maria A; de Villiers, André

    2013-12-01

    Hydrophilic interaction chromatography (HILIC) provides an alternative separation mode for the analysis of phenolic compounds, in which aqueous-organic mobile phases with polar stationary phases are used. This paper reports the evaluation of HILIC for the analysis of the natural pigments anthocyanins, which are of importance because of their chromophoric properties and a range of health benefits associated with their consumption. Several HILIC stationary phases (silica, diol, amine, cyanopropyl and amide) and mobile phase combinations were evaluated, with the latter proving particularly important due to the distinctive chromatographic behaviour of anthocyanins. Diode array detection was used for selective detection of anthocyanins, while high resolution quadrupole-time-of-flight mass spectrometry (Q-TOF-MS) was used for compound identification. The potential of HILIC separation is demonstrated for a range of anthocyanins varying in glycosylation and acylation patterns found in blueberries, grape skins, black beans, red cabbage and red radish. HILIC is shown to be a complementary separation method to reversed phase liquid chromatography (RP-LC) due to the alternative retention mechanism. PMID:24188998

  4. Microwave-assisted synthesis and reversed-phase high-performance liquid chromatographic separation of diastereomers of (R,S)-baclofen using ten chiral derivatizing reagents designed from trichloro-s-triazine.

    PubMed

    Bhushan, Ravi; Dixit, Shuchi

    2010-10-01

    Four dichloro-s-triazine (DCT) and five monochloro-s-triazine (MCT) chiral derivatizing reagents (CDRs) were synthesized by incorporating amino acid amide moieties as chiral auxiliaries in trichloro-s-triazine and its 6-methoxy derivative, respectively. Another MCT reagent was synthesized by substitution of two chlorine atoms with two different amino acid amides in trichloro-s-triazine. These reagents were used for synthesis of diastereomers of (R,S)-baclofen under microwave irradiation (i.e. 60 s at 85% power using DCT reagents and 90 s at 85% power using MCT reagents). The diastereomers were separated on a reversed-phase C18 column using mixtures of methanol with aqueous trifluoroacetic acid (TFA) with UV detection at 230 nm. The separation behavior in terms of retention times and resolutions obtained for the two sets of diastereomers prepared with DCT and MCT reagents were compared among themselves and among the two groups. Longer retention times and better resolutions were observed with DCT reagents as compared to MCT reagents. The calibration curves were linear for both (R)- and (S)-baclofen in the concentration range 50-500 μg/ml. The average regression was 0.999 for both (R)- and (S)-baclofen. The RSD for (R)-baclofen was 0.40-0.86% for intra-day precision and 0.60-1.40% for inter-day precision and these values for (S)-baclofen were 0.52-0.75% and 0.64-1.32%, respectively. The recovery was 97.2-98.9% for (R)- and 97.0-98.9% for (S)-baclofen. The limit of detection was 1.63 ng/ml and 1.52 ng/ml for (R)- and (S)-baclofen, respectively. PMID:20817188

  5. Characterization of Gas Chromatographic Liquid Phases Using McReynolds Constants. An Experiment for Instrumental Analysis Laboratory.

    ERIC Educational Resources Information Center

    Erskine, Steven R.; And Others

    1986-01-01

    Describes a laboratory experiment that is designed to aid in the understanding of the fundamental process involved in gas chromatographic separations. Introduces the Kovats retention index system for use by chemistry students to establish criteria for the optimal selection of gas chromatographic stationary phases. (TW)

  6. Combined liquid chromatograph/mass spectrometer for involatile biological samples.

    PubMed

    Blakley, C R; Carmody, J C; Vestal, M L

    1980-09-01

    A new liquid chromatograph/mass spectrometer has been developed in our laboratory for application to analysis of biological molecules of extremely low volatility. Oxyhydrogen flames rapidly vaporize the total liquid-chromatographic effluent, and molecular and particle beam techniques are used to efficiently transfer the sample to the ionization source of the mass spectrometer. This new instrument is comparable in cost and complexity to a combined gas chromatograph/mass spectrometer, but extends the capabilities of combined chromatography/mass spectrometry to a broad range of compounds not previously accessible. We are currently testing biologically significant samples with this instrument, using reversed-phase liquid-chromatographic separation and both positive and negative ion chemical-ionization mass spectrometry. Results have been obtained from mixtures of nucleic acid components--bases, nucleosides, and nucleotides--and from amino acids, peptides, saccharides, fatty acids, vitamins, and antibiotics. In all cases investigated to date, ions indicative of molecular mass are obtained in at least one of the operating modes available. Detection limits are typically in the 1-10 ng range for full mass scans (about 80-600 amu); sub-nanogram quantities are usually detectable with single-ion monitoring. PMID:7408175

  7. Synthesis of Cellulose Acetate from Cotton Byproducts

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cotton burr and cottonseed hull are relatively inexpensive cotton byproducts. In an effort to derive greater value out of these natural renewable materials, we have succeeded in converting part of them into cellulose acetate without prior chemical breakdown or physical separation of cellulose, ligni...

  8. Model-based rational strategy for chromatographic resin selection.

    PubMed

    Nfor, Beckley K; Zuluaga, Diego S; Verheijen, Peter J T; Verhaert, Peter D E M; van der Wielen, Luuk A M; Ottens, Marcel

    2011-01-01

    A model-based rational strategy for the selection of chromatographic resins is presented. The main question being addressed is that of selecting the most optimal chromatographic resin from a few promising alternatives. The methodology starts with chromatographic modeling,parameters acquisition, and model validation, followed by model-based optimization of the chromatographic separation for the resins of interest. Finally, the resins are rationally evaluated based on their optimized operating conditions and performance metrics such as product purity, yield, concentration, throughput, productivity, and cost. Resin evaluation proceeds by two main approaches. In the first approach, Pareto frontiers from multi-objective optimization of conflicting objectives are overlaid for different resins, enabling direct visualization and comparison of resin performances based on the feasible solution space. The second approach involves the transformation of the resin performances into weighted resin scores, enabling the simultaneous consideration of multiple performance metrics and the setting of priorities. The proposed model-based resin selection strategy was illustrated by evaluating three mixed mode adsorbents (ADH, PPA, and HEA) for the separation of a ternary mixture of bovine serum albumin, ovalbumin, and amyloglucosidase. In order of decreasing weighted resin score or performance, the top three resins for this separation were ADH [PPA[HEA. The proposed model-based approach could be a suitable alternative to column scouting during process development, the main strengths being that minimal experimentation is required and resins are evaluated under their ideal working conditions, enabling a fair comparison. This work also demonstrates the application of column modeling and optimization to mixed mode chromatography. PMID:22238769

  9. Liquid chromatographic determination of clobetasone-17-butyrate in ointments.

    PubMed

    Patel, A G; Patel, R B; Patel, M R

    1990-01-01

    A liquid chromatographic (LC) method has been developed for determination of clobetasone-17-butyrate in ointment using clobetasone propionate as an internal standard. Separation was carried out on a C18 reverse-phase column using water-methanol as a mobile phase. Methylparaben and propylparaben (both sodium salt) used as preservatives did not interfere with separation. Compounds are detected photometrically at 235 nm. Mean assay results for 0.05% commercial ointments were 100.36% (n = 5). Mean recovery of clobetasone-17-butyrate added to commercial ointment was 99.89%. PMID:2289922

  10. Using Aspen to Teach Chromatographic Bioprocessing: A Case Study in Weak Partitioning Chromatography for Biotechnology Applications

    ERIC Educational Resources Information Center

    Evans, Steven T.; Huang, Xinqun; Cramer, Steven M.

    2010-01-01

    The commercial simulator Aspen Chromatography was employed to study and optimize an important new industrial separation process, weak partitioning chromatography. This case study on antibody purification was implemented in a chromatographic separations course. Parametric simulations were performed to investigate the effect of operating parameters…

  11. Isolation and characterization of esters of indole-3-acetic acid from the liquid endosperm of the horse chestnut (Aesculus species)

    NASA Technical Reports Server (NTRS)

    Domagalski, W.; Schulze, A.; Bandurski, R. S.

    1987-01-01

    Esters of indole-3-acetic acid were extracted and purified from the liquid endosperm of immature fruits of various species of the horse chestnut (Aesculus parviflora, A. baumanni, A. pavia rubra, and A. pavia humulis). The liquid endosperm contained, at least 12 chromatographically distinct esters. One of these compounds was purified and characterized as an ester of indole-3-acetic acid and myo-inositol. A second compound was found to be an ester of indole-3-acetic acid and the disaccharide rutinose (glucosyl-rhamnose). A third compound was partially characterized as an ester of indole-3-acetic acid and a desoxyaminohexose.

  12. A universal comparison study of chromatographic response functions.

    PubMed

    Tyteca, Eva; Desmet, Gert

    2014-09-26

    We report on a large scale in silico comparison study of so-called chromatographic response functions (CRFs). These are single number descriptors of the separation quality that can be used to guide search-based optimizations for chromatographic separations. A comprehensive set of literature and new CRFs were compared for their ability to guide a search based on first order chromatographic data (i.e., no spectral information available) and for cases where the number of sample compounds is not known beforehand. The results are discussed based on the available separation power. It was found that CRFs increasing monotonically with the number of observed peaks perform significantly better than those that do not possess this property. CRFs based on the discrimination factor or the peak-to-valley ratio can better cope with peak asymmetry than CRFs based on Snyder resolution Rs. Unfortunately, the former lose their advantage as soon as the noise level becomes significant. Most CRFs perform best when the search is conducted on a column offering just, or, even better, a bit less than the required efficiency to baseline separate the sample. The best results over the entire range of possible efficiencies are obtained with a CRF giving preference to the number of observed compounds before further ranking the conditions based on the achieved separation resolution or the required analysis time. When the search is conducted on columns with an insufficient efficiency, even the best possible CRFs suffer from the incomplete information about the sample, and deviating searches cannot be avoided without resorting to spectral information of the sample. PMID:25171945

  13. A new integrated membrane filtration and chromatographic device.

    PubMed

    Xu, Yanke; Sirkar, Kamalesh K; Dai, Xiao-Ping; Luo, Robert G

    2005-01-01

    To improve protein separation, a novel integrated device combining membrane filtration and chromatography has been developed. The device basically consists of a hollow fiber filtration module whose shell side is filled with chromatographic resin beads. However, there is an essentially impermeable coated zone near the hollow fiber module outlet. The integrated device enjoys the advantages of both membrane filtration and chromatography; it also allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane; the rest of the hollow fiber membrane remained unaffected. Myoglobin (Mb) and alpha-lactalbumin (alpha-LA) were primarily used as model proteins in a binary mixture; binary mixtures of Mb and bovine serum albumin (BSA) were also investigated. Separation behaviors of binary protein mixtures were studied in devices having either an ultrafiltration (UF) or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after introducing the impermeable coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, four loading-washing-elution-reequilibration-based cyclic runs for separation of Mb and alpha-LA were performed in the device using a MF membrane with a coated zone without cleaning in between. The Mb and alpha-LA elution profiles for the four consecutive runs were almost superimposable. Due to lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem, unlike in conventional microfiltration. PMID:15801803

  14. High-performance liquid chromatographic analysis of ampicillin.

    PubMed

    Tsuji, K; Robertson, J H

    1975-09-01

    A high-pressure liquid chromatographic method for the analysis of ampicillin is described. The method uses a 1-m long stainless steel column packed with anionic exchange resin, with a mobile phase of 0.02 M NaNO3 in 0.01 M pH 9.15 borate buffer at a flow rate of 0.45 ml/min. The degradation products of ampicillin, penicillenic and penicilloic acids of ampicillin, can be separated and quantitated in less than 12 min of chromatographic time. The relative standard deviation for the analysis of ampicillin is less than 1%, and the method is sensitive to approximately 20 ng of ampicillin/sample injected. The method was applied to the analysis of various pharmaceutical preparations of ampicillin. It is also applicable, with a slight modification, for the analysis of penicillins G and V. PMID:1185575

  15. Comparison of high performance TLC and HPLC for separation and quantification of chlorogenic acid in green coffee bean extracts.

    PubMed

    Urakova, Irina N; Pozharitskaya, Olga N; Shikov, Alexander N; Kosman, Vera M; Makarov, Valery G

    2008-02-01

    Two chromatographic methods, high-performance TLC (HPTLC) and HPLC, were developed and used for separation and quantitative determination of chlorogenic acid in green coffee bean extracts. For HPTLC silica gel Kieselgel 60 F 254 plates with ethyl acetate/dichlormethane/formic acid/acetic acid/water (100:25:10:10:11, v/v/v/v/v) as mobile phase were used. Densitometric determination of chlorogenic acid by HPTLC was performed at 330 nm. A gradient RP HPLC method was carried out at 330 nm. All necessary validation tests for both methods were developed for their comparison. There were no statistically significant differences between HPLC and HPTLC for quantitative determination of chlorogenic acid according to the test of equality of the means. PMID:18183554

  16. Evaluation of portable gas chromatographs

    SciTech Connect

    Berkley, R.E.; Miller, M.; Chang, J.C.; Oliver, K.; Fortune, C.

    1993-01-01

    Limits of detection, linearity of responses, and stability of response factors and retention times for five commercially-available portable gas chromatographs (PGC) were determined during laboratory evaluation. The PGCs were also operated at the French Limited Superfund site near Houston, TX during startup of bioremediation. Concentrations of volatile organic compounds (VOC) at the site were slightly above ambient background levels. Concurrent collocated grab samples were collected periodically in canisters and analyzed by Method TO-14 using a mass-selective detector. Canister data were taken to indicate correct concentrations and were used to assess the accuracy of PGC data. Durability, reliability, and complexity of operation of PGCs were also evaluated. The principal goal of the study was to determine the best way to use each instrument as a monitor for airborne VOCs.

  17. Non-chromatographic atomic spectrometric methods in speciation analysis: A review

    NASA Astrophysics Data System (ADS)

    Vieira, Mariana A.; Grinberg, Patricia; Bobeda, Cláudio R. R.; Reyes, Mariela N. M.; Campos, Reinaldo C.

    2009-06-01

    In recent years, knowledge of the different chemical forms of the elements has gained increasing importance. There has been significant progress in methods that hyphenate chromatographic separations with atomic spectrometry. These hyphenated methods can provide the most complete information on the species distribution and even structure. However, they can be lengthy, relatively costly and difficult to bring to the routine. On the other hand, it is important to remember that chromatographic techniques represent only a minor part of the separation procedures available and, in certain cases, the application of basic chemistry to sample treatments can give quantitative information about specific chemical forms. In this sense, non-chromatographic procedures can provide methods that offer sufficient information on the elemental speciation for a series of situations. Moreover, these non-chromatographic strategies can be less time consuming, more cost effective and available, and present competitive limits of detection. Thus, non-chromatographic speciation analysis continues to be a promising research area and has been applied to the development of several methodologies that facilitate this type of analytical approach. In view of their importance, the present work overviews and discusses different non-chromatographic methods as alternatives for the speciation analysis of clinical, environmental and food samples using atomic spectrometry for detection.

  18. Fundamental characteristics of synthetic adsorbents intended for industrial chromatographic separations.

    PubMed

    Adachi, Tadashi; Isobe, Eiji

    2004-05-14

    With the aim of obtaining comprehensive information on the selection of synthetic adsorbents for industrial applications, effect of pore and chemical structure of industrial-grade synthetic adsorbents on adsorption capacity of several pharmaceutical compounds was investigated. For relatively low molecular mass compounds, such as cephalexin, berberine chloride and tetracycline hydrochloride, surface area per unit volume of polystyrenic adsorbents dominated the equilibrium adsorption capacity. On the contrary, effect of pore size of the polystyrenic adsorbents on the equilibrium adsorption capacity was observed for relatively high molecular mass compounds, such as rifampicin, Vitamin B12 and insulin. Polystyrenic adsorbent with high surface area and small pore size showed small adsorption capacity for relatively high molecular mass compounds, whereas polystyrenic adsorbent with relatively small surface area but with large pore size showed large adsorption capacity. Effect of chemical structure on the equilibrium adsorption capacity of several pharmaceutical compounds was also studied among polystyrenic, modified polystyrenic and polymethacrylic adsorbents. The modified polystyrenic adsorbent showed larger adsorption capacity for all compounds tested in this study due to enhanced hydrophobicity. The polymethacrylic adsorbent possessed high adsorption capacity for rifampicin and insulin, but it showed lower adsorption capacity for the other compounds studied. This result may be attributed to hydrogen bonding playing major role for the adsorption of compounds on polymethacrylic adsorbent. Furthermore, column adsorption experiments were operated to estimate the effect of pore characteristics of the polystyrenic adsorbents on dynamic adsorption behavior, and it is found that both surface area and pore size of the polystyrenic adsorbents significantly affect the dynamic adsorption capacity as well as flow rate. PMID:15139411

  19. cis- and trans-Stilbenes: Chromatographic Separation and Photochemical Isomerization.

    ERIC Educational Resources Information Center

    Levine, Samuel G.; And Others

    1988-01-01

    Describes an experiment that is to be performed midway in the first semester of an undergraduate organic chemistry laboratory coinciding with the students' introduction to cis-trans isomerism in the study of alkenes. Discusses the apparatus, materials, experimental procedure, historical significance, and results. (CW)

  20. Rapid and sensitive LC-MS/MS method for determination of megestrol acetate in human plasma: application to a human pharmacokinetic study.

    PubMed

    Seo, Ji-Hyung; Park, Ji-Sun; Jo, Min-Ho; Park, Mi-Sun; Ryu, Ju-Hee; Cho, Young-Wuk; Shim, Wang-Sup; Noh, Gyu-Jeong; Lee, Kyung-Tae

    2013-04-01

    A rapid, simple and fully validated LC-MS/MS method was developed and validated for the determination of megestrol acetate in human plasma using tolbutamide as an internal standard (IS) after one-step liquid-liquid extraction with methyl-tert-butyl-ether. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the transitions m/z 385.5 → 267.1 for megestrol acetate and m/z 271.4 → 155.1 for IS. Chromatographic separation was performed on a YMC Hydrosphere C18 column with an isocratic mobile phase, which consisted of 10 mm ammonium formate buffer (adjusted to pH 5.0 with formic acid)-methanol (60:40, v/v) at a flow rate of 0.4 mL/min. The achieved lower limit of quantitation (LLOQ) was 1 ng/mL (signal-to-noise ratio > 10) and the standard calibration curve for megestrol acetate was linear (r > 0.99) over the studied concentration range (1-2000 ng/mL). The proposed method was fully validated by determining its specificity, linearity, LLOQ, intra- and inter-day precision and accuracy, recovery, matrix effect and stability. The validated LC-MS/MS method was successfully applied for the evaluation of pharmacokinetic parameters of megestrol acetate after oral administration of a single dose 800 mg of megestrol acetate (Megace™) to five healthy Korean male volunteers under fed conditions. PMID:22961730

  1. Validation of a Stability-Indicating Hydrophilic Interaction Liquid Chromatographic Method for the Quantitative Determination of Vitamin K3 (Menadione Sodium Bisulfite) in Injectable Solution Formulation

    PubMed Central

    Ghanem, Mashhour M.; Abu-Lafi, Saleh A.; Hallak, Hussein O.

    2013-01-01

    A simple, specific, accurate, and stability-indicating method was developed and validated for the quantitative determination of menadione sodium bisulfite in the injectable solution formulation. The method is based on zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) coupled with a photodiode array detector. The desired separation was achieved on the ZIC-HILIC column (250 mm × 4.6 mm, 5 μm) at 25°C temperature. The optimized mobile phase consisted of an isocratic solvent mixture of 200mM ammonium acetate (NH4AC) solution and acetonitrile (ACN) (20:80; v/v) pH-adjusted to 5.7 by glacial acetic acid. The mobile phase was fixed at 0.5 ml/min and the analytes were monitored at 261 nm using a photodiode array detector. The effects of the chromatographic conditions on the peak retention, peak USP tailing factor, and column efficiency were systematically optimized. Forced degradation experiments were carried out by exposing menadione sodium bisulfite standard and the injectable solution formulation to thermal, photolytic, oxidative, and acid-base hydrolytic stress conditions. The degradation products were well-resolved from the main peak and the excipients, thus proving that the method is a reliable, stability-indicating tool. The method was validated as per ICH and USP guidelines (USP34/NF29) and found to be adequate for the routine quantitative estimation of menadione sodium bisulfite in commercially available menadione sodium bisulfite injectable solution dosage forms. PMID:24106670

  2. Proteomic Analysis on Acetate Metabolism in Citrobacter sp. BL-4

    PubMed Central

    Kim, Young-Man; Lee, Sung-Eun; Park, Byeoung-Soo; Son, Mi-Kyung; Jung, Young-Mi; Yang, Seung-Ok; Choi, Hyung-Kyoon; Hur, Sung-Ho; Yum, Jong Hwa

    2012-01-01

    Mass production of glucosamine (GlcN) using microbial cells is a worthy approach to increase added values and keep safety problems in GlcN production process. Prior to set up a microbial cellular platform, this study was to assess acetate metabolism in Citrobacter sp. BL-4 (BL-4) which has produced a polyglucosamine PGB-2. The LC-MS analysis was conducted after protein separation on the 1D-PAGE to accomplish the purpose of this study. 280 proteins were totally identified and 188 proteins were separated as acetate-related proteins in BL-4. Acetate was converted to acetyl-CoA by acetyl-CoA synthetase up-regulated in the acetate medium. The glyoxylate bypass in the acetate medium was up-regulated with over-expression of isocitrate lyases and 2D-PAGE confirmed this differential expression. Using 1H-NMR analysis, the product of isocitrate lyases, succinate, increased about 15 times in the acetate medium. During acetate metabolism proteins involved in the lipid metabolism and hexosamine biosynthesis were over-expressed in the acetate medium, while proteins involved in TCA cycle, pentose phosphate cycle and purine metabolism were down-regulated. Taken together, the results from the proteomic analysis can be applied to improve GlcN production and to develop metabolic engineering in BL-4. PMID:22211106

  3. Shrinking-core modeling of binary chromatographic breakthrough.

    PubMed

    Traylor, Steven J; Xu, Xuankuo; Lenhoff, Abraham M

    2011-04-22

    Most chromatographic processes involve separation of two or more species, so development of a simple, accurate multicomponent chromatographic model can be valuable for improving process efficiency and yield. We consider the case of breakthrough chromatography, which has been considered in great depth for single-component modeling but to a much more limited degree for multicomponent breakthrough. We use the shrinking core model, which provides a reasonable approximation of particle uptake for proteins under strong binding conditions. Analytical column solutions for single-component systems are extended here to predict binary breakthrough chromatographic behavior for conditions under which the external transport resistance is negligible. Analytical results for the location and profile of displacement effects and expected breakthrough curves are derived for limiting cases. More generally, straightforward numerical results have also been obtained through simultaneous solution of a set of simple ordinary differential equations. Exploration of the model parameter space yields results consistent with theoretical expectations. Additionally, both analytical and numerical predictions compare favorably with experimental column breakthrough data for lysozyme-cytochrome c mixtures on the strong cation exchanger SP Sepharose FF. Especially significant is the ability of the model to predict experimentally observed displacement profiles of the more weakly adsorbed species (in this case cytochrome c). The ability to model displacement behavior using simple analytical and numerical techniques is a significant improvement over current methods. PMID:21411102

  4. Determination of imidacloprid and benzimidazole residues in fruits and vegetables by liquid chromatography-mass spectrometry after ethyl acetate multiresidue extraction.

    PubMed

    Fernández-Alba, A R; Tejedor, A; Agüera, A; Contreras, M; Garrido, J

    2000-01-01

    A simple and sensitive method based on liquid chromatography-atmospheric pressure ionization-mass spectrometry is described for the determination of 4 benzimidazole pesticides (carbendazim, thiabendazole, benomyl, and thiophanate-methyl) and imidacloprid in vegetables and fruits. Food samples were typically extracted with ethyl acetate to draw the analytes into the organic phase. No cleanup step was necessary before injection into the liquid chromatographic (LC) system with electrospray mass spectrometric detection. The analytes were separated on a reversed-phase C8LC column. Limits of detection for the compounds were in the microg/L range. Results are reported for validation studies with fortified pear and tomato samples and for residues of the target compounds found in the pesticide residue monitoring program during 1998. PMID:10868600

  5. Acetate Dependence of Tumors

    PubMed Central

    Comerford, Sarah A.; Huang, Zhiguang; Du, Xinlin; Wang, Yun; Cai, Ling; Witkiewicz, Agnes; Walters, Holly; Tantawy, Mohammed N.; Fu, Allie; Manning, H. Charles; Horton, Jay D.; Hammer, Robert E.; McKnight, Steven L.; Tu, Benjamin P.

    2014-01-01

    SUMMARY Acetyl-CoA represents a central node of carbon metabolism that plays a key role in bioenergetics, cell proliferation and the regulation of gene expression. How highly glycolytic or hypoxic tumors are able to produce sufficient quantities of this metabolite to support cell growth and survival under nutrient-limiting conditions remains poorly understood. Here we show that the nucleocytosolic acetyl-CoA synthetase enzyme, ACSS2, supplies a key source of acetyl-CoA for tumors by capturing acetate as a carbon source. Despite exhibiting no gross deficits in growth or development, adult mice lacking ACSS2 exhibit a significant reduction in tumor burden in two different models of hepatocellular carcinoma. ACSS2 is expressed in a large proportion of human tumors and its activity is responsible for the majority of cellular acetate uptake into both lipids and histones. These observations may qualify ACSS2 as a targetable metabolic vulnerability of a wide spectrum of tumors. PMID:25525877

  6. Fast separation of selected cathinones and phenylethylamines by supercritical fluid chromatography.

    PubMed

    Pauk, Volodymyr; Žihlová, Veronika; Borovcová, Lucie; Havlíček, Vladimír; Schug, Kevin; Lemr, Karel

    2015-12-01

    The chromatographic behaviour of eleven synthetic cathinones and four phenylethylamines under supercritical/subcritical fluid conditions was investigated. Four stationary phases with sub-2μm particles (Waters Acquity UPC(2) BEH silica, BEH 2-ethylpyridine, CSH Fluoro-Phenyl, and HSS C18SB) were evaluated in terms of isomer resolution, chromatographic peak shape, and analysis time. Methanol, water, formic acid, ammonium hydroxide, ammonium acetate, and ammonium formate were mixed with carbon dioxide to test their influence on analyte retention and peak shapes. Methanol and ammonium cations were essential for successful separations. Efficient separations of four isomeric pairs (R>1), and most of the remaining analytes, were achieved in less than 3.3min on BEH and Fluoro-Phenyl columns with gradient of methanolic ammonium hydroxide in CO2. Drugs were detected by positive electrospray ionization-triple quadrupole mass spectrometry in selected reaction monitoring mode. Added detection specificity and faster separation of isomers on the BEH column using a steep gradient and high flow rate reduced analysis time of the mixture of 15 drugs to 1.6min. PMID:26585202

  7. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, T.G.; Ives, J.T.

    1993-12-28

    A method and apparatus are presented for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means. 16 figures.

  8. Gas chromatographic analysis of trace gas impurities in tungsten hexafluoride.

    PubMed

    Laurens, J B; de Coning, J P; Swinley, J M

    2001-03-01

    Highly reactive fluorinated gaseous matrices require special equipment and techniques for the gas chromatographic analysis of trace impurities in these gases. The impurities that were analysed at the low-microg/l levels included oxygen, nitrogen, carbon dioxide, carbon monoxide, sulfur hexafluoride and hydrogen. This paper describes the use of a system utilising backflush column switching to protect the columns and detectors in the analysis of trace gas impurities in tungsten hexafluoride. Two separate channels were used for the analysis of H2, O2, N2, CO, CO2 and SF6 impurities with pulsed discharge helium ionisation detection. PMID:11269587

  9. [Determining thorium level in urine with its preliminary chromatographic extraction].

    PubMed

    Kononykina, N N; Astafurov, V I; Zablotskaia, I D; Popov, V I

    1990-01-01

    The contributors propose a radiometric technique of detecting thorium in urine. The technique is based on a prior concentrating of the nuclide on phosphate residues, with its further separation in extraction-chromatographic vessel filled with diethylhexylphosphorus acid, and reextraction with oxalic acid. Measurements were made in the hard scintillator layer at 90 percent effectiveness. Thorium chemical output was at 85 +/- 3 percent, sensitivity at 5 mBk for a sample. If the sample contained an equal quantity of uranium, the percentage of cleaning thorium from uranium was 100. The proposed technique is economical, simple to perform, and is designed for natural thorium content measurements in human organism. PMID:2086364

  10. Methods and apparatus for analysis of chromatographic migration patterns

    DOEpatents

    Stockham, Thomas G.; Ives, Jeffrey T.

    1993-01-01

    A method and apparatus for sharpening signal peaks in a signal representing the distribution of biological or chemical components of a mixture separated by a chromatographic technique such as, but not limited to, electrophoresis. A key step in the method is the use of a blind deconvolution technique, presently embodied as homomorphic filtering, to reduce the contribution of a blurring function to the signal encoding the peaks of the distribution. The invention further includes steps and apparatus directed to determination of a nucleotide sequence from a set of four such signals representing DNA sequence data derived by electrophoretic means.

  11. Chromatographic resolution of closely related species: drug metabolites and analogs.

    PubMed

    Regalado, Erik L; Helmy, Roy; Green, Mitchell D; Welch, Christopher J

    2014-05-01

    In this study, we investigate the separation of a variety of mixtures of drugs, metabolites, and related analogs including representatives of the carbamazepine, methylated xanthine, steroid hormone, nicotine, and morphine families using several automated chromatographic method development screening systems including ultra high performance liquid chromatography, core-shell HPLC, achiral supercritical fluid chromatography (SFC), and chiral SFC. Of the 138 column and mobile phase combinations examined for each mixture, a few chromatographic conditions afford the best overall performance, with a single achiral SFC method (4.6 × 250 mm, 3.0 μm GreenSep Ethyl Pyridine, 25 mM isobutylamine in methanol/CO2) affording good separation for all samples. Four of these mixtures were also resolved by achiral SFC on the Luna HILIC and chiral SFC Chiralpak IB columns using methanol or ethanol with 25 mM isobutylamine as polar modifiers. Modifications of standard chromatography screening conditions afforded fast separation methods (from 1 to 5 min) for baseline resolution of all components of each of these challenging sets of closely related compounds. PMID:24596023

  12. Two-dimensional thin-layer chromatographic method for the analysis of ochratoxin A in green coffee.

    PubMed

    Ventura, Meritxell; Anaya, Ivan; Broto-Puig, Francesc; Agut, Montserrat; Comellas, Lluís

    2005-09-01

    A low-cost thin-layer chromatographic method has been developed for the presumptive measurement of ochratoxin A (OTA) at 5 microg/kg in green coffee beans. The analytical method consisted of extracting OTA by shaking the beans with a mixture of methanol and aqueous sodium bicarbonate solution, which was then purified by liquid-liquid partition into toluene. OTA was separated by normal-phase two-dimensional thin-layer chromatography and detected by visual estimation of fluorescence intensity under a UV lamp at 365 nm. The chromatography solvents were toluene-methanol-formic acid (8:2:0.03) for the first development and petroleum ether-ethyl acetate-formic acid (8:10:1) for the second dimension development. This method was tested with uncontaminated green coffee bean samples spiked with an OTA standard at four different concentrations (5, 10, 20, and 30 microg/kg). The method is rapid, simple, and very easy to implement in coffee-producing countries. It is highly selective and does not involve the use of chlorinated solvents in the sample extraction step. This inexpensive method has been applied to different types of green coffee samples from various countries (Zimbabwe, Brazil, India, Uganda, Colombia, and Indonesia) and different manufacturers, and no OTA below the detection limit of 5 microg/kg was detected in any samples analyzed. PMID:16161695

  13. Ultra-performance liquid chromatographic determination of L-ergothioneine in commercially available classes of cow milk.

    PubMed

    Sotgia, Salvatore; Pisanu, Elisabetta; Cambedda, Debora; Pintus, Gianfranco; Carru, Ciriaco; Zinellu, Angelo

    2014-09-01

    A new efficient and sensitive precolumn hydrophilic interaction ultra-performance liquid chromatography (HILIC-UPLC) method was established for the quantitative determination of L-ergothioneine (ERT) in milk. After derivatization of ERT with 7-diethylamino-3-[4-(iodoacetamido)phenyl]-4-methylcoumarin, chromatographic separation was achieved in a fairly short time, less than 5 min, on a 100 × 2.1 mm Waters Cortecs UPLC HILIC 1.6-μm column, by using a mixture of 30 mmol/L ammonium acetate/acetonitrile (10:90, v/v) as a mobile phase flowing isocratically at 0.9 mL/min. Limit of detection and the limit of quantification were 0.03 and 0.10 μmol/L, respectively. The method exhibited linearity in a concentration range of 0.16 and 5.08 μmol/L. Mean recovery was 106.66%, whereas intra- and interassay precisions were determined to be within 6 RSD%. On average, ERT concentration in different commercially available classes of cow milk was found to be 0.442 ± 0.191 μmol/L, with the highest levels in the ultra-high temperature milks and low values in the unprocessed and HTST whole milks. In this light, our experiments suggest that ERT could be used as a marker for the heat treatment of milk. PMID:25154712

  14. Development and Validation of Stability-indicating High Performance Liquid Chromatographic Method for the Estimation of Everolimus in Tablets

    PubMed Central

    Sharmila, D.; Rao, A. Lakshmana; Kalyani, L.

    2015-01-01

    The present study depicts the development of a validated reversed-phase high performance liquid chromatographic method for the determination of the everolimus in presence of degradation products or pharmaceutical excipients. Stress study was performed on everolimus and it was found that it degrade sufficiently in oxidizing and acidic conditions but less degradation was found in alkaline, neutral, thermal and photolytic conditions. The separation was carried out on Hypersil BDS C18 column (100×4.6 mm, 5 μ) column having particle size 5 μ using acetate buffer:acetonitrile (50:50 v/v) with pH 6.5 adjusted with orthophosphoric acid as mobile phase at flow rate of 1 ml/min. The wavelength of the detection was 280 nm. A retention time (Rt) nearly 3.110 min was observed. The calibration curve for everolimus was linear (r2=0.999) from range of 25-150 μg/ml with limit of detection and limit of quantification of 0.036 μg/ml and 0.109 μg/ml, respectively. Analytical validation parameters such as selectivity, specificity, linearity, accuracy and precision were evaluated and relative standard deviation value for all the key parameters were less than 2.0%. The recovery of the drug after standard addition was found to be 100.55%. Thus, the developed RP-HPLC method was found to be suitable for the determination of everolimus in tablets containing various excipients. PMID:26798176

  15. Development and Validation of Stability-indicating High Performance Liquid Chromatographic Method for the Estimation of Everolimus in Tablets.

    PubMed

    Sharmila, D; Rao, A Lakshmana; Kalyani, L

    2015-01-01

    The present study depicts the development of a validated reversed-phase high performance liquid chromatographic method for the determination of the everolimus in presence of degradation products or pharmaceutical excipients. Stress study was performed on everolimus and it was found that it degrade sufficiently in oxidizing and acidic conditions but less degradation was found in alkaline, neutral, thermal and photolytic conditions. The separation was carried out on Hypersil BDS C18 column (100×4.6 mm, 5 μ) column having particle size 5 μ using acetate buffer:acetonitrile (50:50 v/v) with pH 6.5 adjusted with orthophosphoric acid as mobile phase at flow rate of 1 ml/min. The wavelength of the detection was 280 nm. A retention time (Rt) nearly 3.110 min was observed. The calibration curve for everolimus was linear (r(2)=0.999) from range of 25-150 μg/ml with limit of detection and limit of quantification of 0.036 μg/ml and 0.109 μg/ml, respectively. Analytical validation parameters such as selectivity, specificity, linearity, accuracy and precision were evaluated and relative standard deviation value for all the key parameters were less than 2.0%. The recovery of the drug after standard addition was found to be 100.55%. Thus, the developed RP-HPLC method was found to be suitable for the determination of everolimus in tablets containing various excipients. PMID:26798176

  16. A Quantitative Gas Chromatographic Ethanol Determination.

    ERIC Educational Resources Information Center

    Leary, James J.

    1983-01-01

    Describes a gas chromatographic experiment for the quantitative determination of volume percent ethanol in water ethanol solutions. Background information, procedures, and typical results are included. Accuracy and precision of results are both on the order of two percent. (JN)

  17. Gas Chromatographic Determination of Enrivonmentally Significant Pesticides.

    ERIC Educational Resources Information Center

    Rudzinski, Walter E.; Beu, Steve

    1982-01-01

    A chromatographic procedure for analyzing organophosphorus pesticides (such as PCB's, nitrosamines, and phthalate esters) in orange juice is described, including a summary of the method, instrumentation, methodology, results/discussion, and calculations. (JN)

  18. A Versatile, Automatic Chromatographic Column Packing Device

    ERIC Educational Resources Information Center

    Barry, Eugene F.; And Others

    1977-01-01

    Describes an inexpensive apparatus for packing liquid and gas chromatographic columns of high efficiency. Consists of stainless steel support struts, an Automat Getriebmotor, and an associated three-pulley system capable of 10, 30, and 300 rpm. (MLH)

  19. Gas chromatograph injection port protective device

    NASA Technical Reports Server (NTRS)

    Robertson, M. D.; Welz, E. A.

    1969-01-01

    To prevent samples containing foreign matter from poisoning the gas chromatographic columns, a pre-filter insertion is placed in the injection port. The packing becomes a variable reactant, for example, acids are removed by using an alkaline liquid.

  20. Liquid chromatographic-electrochemical determination of ethylenethiourea in foods by revised official method.

    PubMed

    Krause, R T

    1989-01-01

    AOAC official method 29.119-29.125 was revised to determine ethylenethiourea (ETU) directly by a liquid chromatographic-electrochemical (LC-EC) determinative technique and to improve ETU recovery. ETU is extracted from food products with a methanol-aqueous sodium acetate solution. A portion of the concentrated filtrate is added to a column of diatomaceous earth, and ETU is eluted with 2% methanol in methylene chloride to separate it from food coextractives, which are retained on the column. The eluate is collected in a siliconized flask and evaporated, the residue is dissolved in water, and 20 microL of solution is injected onto an LC graphitized carbon column. ETU is eluted from the LC column with a mobile phase of acetonitrile-aqueous 0.1M phosphoric acid-water (5 + 25 + 70), and the eluted ETU is detected by using an amperometric electrochemical detector equipped with a gold/mercury working electrode. Recovery data were obtained by fortifying 13 food products with ETU: baked potatoes; canned applesauce, mushrooms, creamed spinach, green beans, spinach, and tomatoes; cooked fresh cabbage and frozen collards; fresh celery and lettuce; grape jelly; and powdered sugar cake donuts. Raw celery was found to cause low ETU recoveries. Average percent recoveries of ETU from the other 12 food products were 92 with a standard deviation of 12 for the low (0.05 and 0.1 ppm) fortification levels and 90 with a standard deviation of 6 for the higher (0.5 and 1 ppm) fortification levels. The limits of quantitation were 0.01 and 0.02 ppm for food products with low and high sugar content, respectively. PMID:2592320

  1. Evaluation of Comprehensive 2-D Gas Chromatography-Time-Of-Flight Mass Spectrometry for 209 Chlorinated Biphenyl Congeners in Two Chromatographic Runs

    EPA Science Inventory

    This research evaluates a recently developed comprehensive 2-D GC coupled with a time-of-flight (TOF) mass spectrometer for the potential separation of 209 PCB congeners, using a sequence of 1-D and 2-D chromatographic modes. In two consecutive chromatographic runs, using a 40 m,...

  2. Planar chromatographic method development using the PRISMA optimization system and flow charts.

    PubMed

    Nyiredy, Sz

    2002-01-01

    This study presents a modern planar chromatographic method-development procedure, based on the "PRISMA" optimization system, in which the optimum separation is achieved systematically and the structures and properties of the substances to be separated are not known. The procedure consists of three stages. In the first of these the basic conditions the stationary phase, vapor phase, and individual solvents are selected with a TLC procedure (generally in nonsaturated chromatographic chambers). In the second stage, the optimum combination of the selected solvents is determined with the PRISMA model. The third part of the procedure includes the selection of the development mode (circular, linear, or anticircular); the selection of an appropriate forced-flow chromatographic technique (over-pressured layer chromatography or rotation planar chromatography) with high-performance thin-layer chromatographic plates; the transfer of the optimized mobile phase to the various analytical, planar, or column preparative liquid chromatographic techniques; and the selection of the operating conditions. For practical reasons, the optimization process is presented with the help of flow charts. PMID:12515358

  3. Simultaneous determination of furfural, acetic acid, and 5-hydroxymethylfurfural in corncob hydrolysates using liquid chromatography with ultraviolet detection.

    PubMed

    Dong, Bo-Yu; Chen, Ye-Fu; Zhao, Chang-Chun; Zhang, Shi-Jie; Guo, Xue-Wu; Xiao, Dong-Guang

    2013-01-01

    A single-laboratory validation study was conducted using HPLC for detecting and quantifying acetic acid, furfural, and 5-hydroxymethylfurfural (HMF) in corncob hydrolysates. A pretreatment procedure using dilute sulfuric acid was optimized for corncob hydrolysis. The final hydrolysates were analyzed by HPLC using a C18 RP column with aqueous 0.01% (v/v) H2SO4-CH3OH (95 + 5) as the mobile phase at a flow rate of 1 mL/min. The wavelengths for detecting the three compounds were changed to their optimal UV detection wavelengths at the time of elution. The wavelength detection adjustments were as follow: 205 nm (0 to 4 min); 284 nm (4 to 7 min); and 276 nm (7 to 10 min). Separation was achieved with a chromatographic run time of 10 min. The calibration curves for the three compounds had correlation coefficients (r2) > or = 99.8%. The analytical range, as defined by the calibration curves, was 0.5-10 mg/L for acetic acid, 0.4-22 mg/L for furfural, and 0.1-18 mg/L for HMF. The LODs for acetic acid, furfural, and HMF were estimated to be 0.05, 0.03, and 0.02 mg/L, respectively; the LOQs were 0.196, 0.135, and 0.074 mg/L, respectively. The RSD values for the intraday precision study ranged from 0.31 to 2.22%, and from 0.57 to 2.43% for the interday study. The mean recovery rates in all compounds were between 100.08 and 101.49%. PMID:24645500

  4. CHROMATOGRAPHIC METHODS FOR ANALYSIS OF ETHYLENE OXIDE IN EMISSIONS FROM STATIONARY SOURCES

    EPA Science Inventory

    Chromatographic methods of analysis with FID detection were investigated for quantitation of ethylene oxide in emissions from production-plants and commercial sterilizers. olumn with a stationary phase of 3% Carbowax 20M on 80/lOO Chromsorb 101 was used to separate ethylene oxide...

  5. The effect of oral sodium acetate administration on plasma acetate concentration and acid-base state in horses

    PubMed Central

    Waller, Amanda; Lindinger, Michael I

    2007-01-01

    Aim Sodium acetate (NaAcetate) has received some attention as an alkalinizing agent and possible alternative energy source for the horse, however the effects of oral administration remain largely unknown. The present study used the physicochemical approach to characterize the changes in acid-base status occurring after oral NaAcetate/acetic acid (NAA) administration in horses. Methods Jugular venous blood was sampled from 9 exercise-conditioned horses on 2 separate occasions, at rest and for 24 h following a competition exercise test (CET) designed to simulate the speed and endurance test of 3-day event. Immediately after the CETs horses were allowed water ad libitum and either: 1) 8 L of a hypertonic NaAcetate/acetic acid solution via nasogastric tube followed by a typical hay/grain meal (NAA trial); or 2) a hay/grain meal alone (Control trial). Results Oral NAA resulted in a profound plasma alkalosis marked by decreased plasma [H+] and increased plasma [TCO2] and [HCO3-] compared to Control. The primary contributor to the plasma alkalosis was an increased [SID], as a result of increased plasma [Na+] and decreased plasma [Cl-]. An increased [Atot], due to increased [PP] and a sustained increase in plasma [acetate], contributed a minor acidifying effect. Conclusion It is concluded that oral NaAcetate could be used as both an alkalinizing agent and an alternative energy source in the horse. PMID:18096070

  6. Separation and quantification of microalgal carbohydrates.

    PubMed

    Templeton, David W; Quinn, Matthew; Van Wychen, Stefanie; Hyman, Deborah; Laurens, Lieve M L

    2012-12-28

    Structural carbohydrates can constitute a large fraction of the dry weight of algal biomass and thus accurate identification and quantification is important for summative mass closure. Two limitations to the accurate characterization of microalgal carbohydrates are the lack of a robust analytical procedure to hydrolyze polymeric carbohydrates to their respective monomers and the subsequent identification and quantification of those monosaccharides. We address the second limitation, chromatographic separation of monosaccharides, here by identifying optimum conditions for the resolution of a synthetic mixture of 13 microalgae-specific monosaccharides, comprised of 8 neutral, 2 amino sugars, 2 uronic acids and 1 alditol (myo-inositol as an internal standard). The synthetic 13-carbohydrate mix showed incomplete resolution across 11 traditional high performance liquid chromatography (HPLC) methods, but showed improved resolution and accurate quantification using anion exchange chromatography (HPAEC) as well as alditol acetate derivatization followed by gas chromatography (for the neutral- and amino-sugars only). We demonstrate the application of monosaccharide quantification using optimized chromatography conditions after sulfuric acid analytical hydrolysis for three model algae strains and compare the quantification and complexity of monosaccharides in analytical hydrolysates relative to a typical terrestrial feedstock, sugarcane bagasse. PMID:23177152

  7. Chromatographic removal of endotoxin from protein solutions by polymer particles.

    PubMed

    Hirayama, Chuichi; Sakata, Masayo

    2002-12-01

    Endotoxins, constituents of cell walls of gram-negative bacteria, are potential contaminants of the protein solutions originating from biological products. Such contaminants have to be removed from solutions used for intravenous administration, because of their potent biological activities causing pyrogenic reactions. Separation methods used for decontamination of water, such as ultrafiltration, have little effect on endotoxin levels in protein solutions. To remove endotoxin from a solution of high-molecular-mass compounds, such as proteins, the adsorption method has proven to be most effective. In this review, we first introduce endotoxin-specific properties in an aqueous solution, and then provide various methods of chromatographic separation of endotoxins from cellular products using polymer adsorbents. We also provide the design of novel endotoxin-specific polymer adsorbents. PMID:12450672

  8. [Nomegestrol acetate: clinical pharmacology].

    PubMed

    Lello, S

    2009-10-01

    Progestogens are used in clinical practice in some conditions. Their effects depend on their chemical structure, pharmacokinetics, pharmacodynamics, with important differences among various progestogens. Generally, progestins are classified according to their parent molecule, of which often they keep some features. Derivatives of 19-nor-progesterone are characterized by high selectivity of action on progestin receptor. In particular, nomegestrol acetate (NomAc) shows an important progestational potency, neutral gluco-lipid profile, and antigonadotropic activity. It is used for treating menstrual cycle disorders and for hormone replacement therapy in menopause in association with an estrogen. In future, thanks to its antigonadotropic activity, NomAc will be used in estroprogestin combinations in fertile women, thus taking advantage of its tolerability profile and obtaining numerous non-contraceptive benefits as well. PMID:19749678

  9. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Eckels, Joel D.; Kimmons, James F.; Myers, David W.

    1996-01-01

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  10. Portable gas chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Eckels, J.D.; Kimmons, J.F.; Myers, D.W.

    1996-06-11

    A gas chromatograph-mass spectrometer (GC-MS) is described for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units. 4 figs.

  11. Portable gas chromatograph-mass spectrometer

    SciTech Connect

    Andresen, B.D.; Eckels, J.D.; Kimmins, J.F.; Myers, D.W.

    1994-12-31

    A gas chromatograph-mass spectrometer (GC-MS) for use as a field portable organic chemical analysis instrument. The GC-MS is designed to be contained in a standard size suitcase, weighs less than 70 pounds, and requires less than 600 watts of electrical power at peak power (all systems on). The GC-MS includes: a conduction heated, forced air cooled small bore capillary gas chromatograph, a small injector assembly, a self-contained ion/sorption pump vacuum system, a hydrogen supply, a dual computer system used to control the hardware and acquire spectrum data, and operational software used to control the pumping system and the gas chromatograph. This instrument incorporates a modified commercial quadrupole mass spectrometer to achieve the instrument sensitivity and mass resolution characteristic of laboratory bench top units.

  12. Ion chromatographic determination of sulfur in fuels

    NASA Technical Reports Server (NTRS)

    Mizisin, C. S.; Kuivinen, D. E.; Otterson, D. A.

    1978-01-01

    The sulfur content of fuels was determined using an ion chromatograph to measure the sulfate produced by a modified Parr bomb oxidation. Standard Reference Materials from the National Bureau of Standards, of approximately 0.2 + or - 0.004% sulfur, were analyzed resulting in a standard deviation no greater than 0.008. The ion chromatographic method can be applied to conventional fuels as well as shale-oil derived fuels. Other acid forming elements, such as fluorine, chlorine and nitrogen could be determined at the same time, provided that these elements have reached a suitable ionic state during the oxidation of the fuel.

  13. Multi-target screening of biological samples using LC-MS/MS: focus on chromatographic innovations.

    PubMed

    Kohler, Isabelle; Guillarme, Davy

    2014-05-01

    Multi-target screening of biological fluids is a key tool in clinical and forensic toxicology. A complete toxicological analysis encompasses the sample preparation, the chromatographic separation and the detection. The present review briefly covers the new trends in sample preparation and detection and mainly focuses on the chromatographic stage, since a lot of technical improvements have been proposed over the last years. Among them, columns packed with sub-2 μm fully porous particles and sub-3 μm core-shell particles allow for significant improvements of resolution and higher throughput. Even if reversed-phase LC remains the most widely used chromatographic mode for toxicological screening, hydrophilic interaction chromatography and supercritical fluid chromatography appear as promising alternatives for attaining orthogonal selectivity, retention of polar compounds, and enhanced MS sensitivity. PMID:24946925

  14. Methane Production and Syntrophic Acetate Oxidation in the Florida Everglades

    NASA Astrophysics Data System (ADS)

    Holmes, M. E.; Chanton, J.; Bae, H.; Ogram, A.

    2012-12-01

    Methane production pathways in the Florida Everglades are influenced by factors such as nutrient levels, H2 concentrations, and temperature. Syntrophic acetate oxidizers can outcompete methanogens for acetate when conditions are right (high temperatures and low H2). During syntrophic acetate oxidation (SAO), which becomes more exergonic with increasing temperature, acetate is oxidized to carbon dioxide and H2, which can be utilized to produce methane via CO2 reduction. Everglades soil from along a nutrient gradient was incubated at 25°C and 45°C. The shift to the CO2 reduction pathway for methane formation that would be expected in high temperature incubations due to SAO should result in a decrease in δ13C-CH4 and increase in δ2H-CH4. Instead, we observed higher δ13C and lower δ2H in the methane produced in high temperature incubations. The higher than expected δ13C may be partly explained by lower kinetic isotope effects caused by temperature. Coupling between the syntrophic acetate oxidizers and the CO2 reducers, whereby isotopically light hydrogen from acetate is used in methane formation could lower δ2H-CH4. Separate experiments using 13C-labelled acetate revealed that potential SAO activity is low in soils collected from the Everglades.

  15. Continuous stationary phase gradients for planar chromatographic media.

    PubMed

    Kannan, Balamurali; Marin, Michael A; Shrestha, Kushal; Higgins, Daniel A; Collinson, Maryanne M

    2011-12-30

    A simple, elegant method for the formation of a continuous stationary phase gradient for use in chromatographic separations is described. Its applicability to separation science is demonstrated using thin-layer chromatography as a test case. Gradient stationary phases were formed on activated High Performance Thin-Layer Chromatography (HP-TLC) plates using a newly developed methodology termed "controlled rate infusion". Specifically, the SiOH groups on the activated HP-TLC plates were reacted with 3-aminopropyltriethoxysilane (APTEOS) in a time dependent fashion by using a programmable syringe pump to control the rate of APTEOS infusion into the deposition reservoir. The shape (profile) of the gradient was controlled by the rate of infusion and imaged by taking advantage of the concentration-dependent color formation reaction between amine groups and ninhydrin. The advantages of such gradients in optimizing the retention and separation of various components in different mixtures were illustrated using mixtures of (1) four weak acids and bases and (2) three widely used over-the-counter drugs. The separation of the individual components on the gradient stationary phase was clearly improved relative to those on either traditional normal-phase TLC plates or uniformly amine-modified TLC plates. Precise control over component retention and separation was also demonstrated by strategically modifying the steepness of the gradient. PMID:22119610

  16. Functional chromatographic technique for natural product isolation†

    PubMed Central

    Lau, Eric C.; Mason, Damian J.; Eichhorst, Nicole; Engelder, Pearce; Mesa, Celestina; Kithsiri Wijeratne, E. M.; Gunaherath, G. M. Kamal B.; Leslie Gunatilaka, A. A.

    2015-01-01

    Natural product discovery arises through a unique interplay between chromatographic purification and biological assays. Currently, most techniques used for natural product purification deliver leads without a defined biological action. We now describe a technique, referred to herein as functional chromatography, that deploys biological affinity as the matrix for compound isolation. PMID:25588099

  17. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  18. 40 CFR 1065.267 - Gas chromatograph.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Gas chromatograph. 1065.267 Section 1065.267 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Hydrocarbon Measurements § 1065.267 Gas...

  19. Nano-fabricated size exclusion chromatograph

    NASA Technical Reports Server (NTRS)

    Svehla, D.; Feldman, S.; Feldman, J.; Grunthaner, F.; Shakkottai, P.; dle Castillo, L.; White, V.

    2002-01-01

    This poster describes the development of a nano-fabricated size exclusion chromatograph (nSEC) based on the principle that molecules traveling through a microcolumn containing nano-fabricated features will have characteristics elution times that directly correlate to molecular weight.

  20. Gas chromatographic characterization of vegetable oil deodorization distillate.

    PubMed

    Verleyen, T; Verhe, R; Garcia, L; Dewettinck, K; Huyghebaert, A; De Greyt, W

    2001-07-01

    Because of its complex nature, the analysis of deodorizer distillate is a challenging problem. Deodorizer distillate obtained from the deodorization process of vegetable oils consists of many components including free fatty acids, tocopherols, sterols, squalene and neutral oil. A gas chromatographic method for the analysis of deodorizer distillate without saponification of the sample is described. After a concise sample preparation including derivatization and silylation, distillate samples were injected on column at 60 degrees C followed by a gradual increase of the oven temperature towards 340 degrees C. The temperature profile of the oven was optimized in order to obtain a baseline separation of the different distillate components including free fatty acids, tocopherols, sterols, squalene and neutral oil. Good recoveries for delta-tocopherol, alpha-tocopherol, stigmasterol and cholesteryl palmitate of 97, 94.4, 95.6 and 92%, respectively were obtained. Repeatability of the described gas chromatographic method was evaluated by analyzing five replicates of a soybean distillate. Tocopherols and sterols had low relative standard deviations ranging between 1.67 and 2.25%. Squalene, mono- and diacylglycerides had higher relative standard deviations ranging between 3.33 and 4.12%. Several industrial deodorizer distillates obtained from chemical and physical refining of corn, canola, sunflower and soybean have been analyzed for their composition. PMID:11471811

  1. Method to fabricate silicon chromatographic column comprising fluid ports

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.; Heller, Edwin J.; Adkins, Douglas R.

    2004-03-02

    A new method for fabricating a silicon chromatographic column comprising through-substrate fluid ports has been developed. This new method enables the fabrication of multi-layer interconnected stacks of silicon chromatographic columns.

  2. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... No. 62-54-4), also known as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may be produced by the calcium hydroxide neutralization of acetic acid. (b) The ingredient meets...

  3. Comprehensive two-dimensional liquid chromatographic analysis of poloxamers.

    PubMed

    Malik, Muhammad Imran; Lee, Sanghoon; Chang, Taihyun

    2016-04-15

    Poloxamers are low molar mass triblock copolymers of poly(ethylene oxide) (PEO) and poly(propylene oxide) (PPO), having number of applications as non-ionic surfactants. Comprehensive one and two-dimensional liquid chromatographic (LC) analysis of these materials is proposed in this study. The separation of oligomers of both types (PEO and PPO) is demonstrated for several commercial poloxamers. This is accomplished at the critical conditions for one of the block while interaction for the other block. Reversed phase LC at CAP of PEO allowed for oligomeric separation of triblock copolymers with regard to PPO block whereas normal phase LC at CAP of PPO renders oligomeric separation with respect to PEO block. The oligomeric separation with regard to PEO and PPO are coupled online (comprehensive 2D-LC) to reveal two-dimensional contour plots by unconventional 2D IC×IC (interaction chromatography) coupling. The study provides chemical composition mapping of both PEO and PPO, equivalent to combined molar mass and chemical composition mapping for several commercial poloxamers. PMID:26994923

  4. Virus elimination during the recycling of chromatographic columns used during the manufacture of coagulation factors.

    PubMed

    Roberts, Peter L

    2014-07-01

    Various chromatographic procedures are used during the purification and manufacture of plasma products such as coagulation factors. These steps contribute to the overall safety of such products by removing potential virus contamination. Virus removal by two affinity chromatography procedures, i.e. monoclonal antibody chromatography and metal chelate chromatography (immobilised metal ion affinity chromatography), used during the manufacture of the high purity factor VIII (Replenate®) and factor IX (Replenine®-VF), respectively, has been investigated. In addition, as these columns are recycled after use, the effectiveness of the sanitisation procedures for preventing possible cross-contamination, has also been investigated. Both chromatographic steps proved effective for eliminating a range of model enveloped and non-enveloped viruses by 4 to >6 and 5 to >8 log for the monoclonal and metal chelate columns, respectively. The effectiveness of the relatively mild column sanitisation conditions used, i.e. ethanol for factor IX and acetic acid for factor VIII, was confirmed using non-spiked column runs. The chemicals used contributed to virus elimination by inactivation and/or by physical removal of the virus. In summary, these studies demonstrate that potential virus contamination between chromatographic runs can be prevented when an effective column recycling and sanitisation procedure is included. PMID:24981392

  5. Allyl-silica Hybrid Monoliths For Chromatographic Application

    NASA Astrophysics Data System (ADS)

    Guo, Wenjuan

    Column technology continues to be the most investigated topics in the separation world, since the column is the place where the chromatographic separation happens, making it the heart of the separation system. Allyl-silica hybrid monolithic material has been exploited as support material and potential stationary phases for liquid chromatography; the stationary phase anchored to the silica surface by Si-C bond, which is more pH stable than traditional stationary phase. First, nuclear magnetic resonance spectroscopy has been used to study the sol in the synthesis of allyl-silica hybrid monoliths. Allyl-trimethoxysilane (allyl-TrMOS), dimethyldimethoxysilane (DMDMOS) and tetramethoxysilane (TMOS) have been served as co-precursors in the sol-gel synthesis of organo-silica hybrid monolithic columns for liquid chromatography (LC). 29Si nuclear magnetic resonance (NMR) and 1H NMR spectroscopy were employed to monitor reaction profiles for the acid-catalyzed hydrolysis and initial condensation reactions of the individual precursor and the hybrid system. 29Si-NMR has also been used to identify different silane species formed during the reactions. The overall hydrolysis rate has been found to follow the trend DMDMOS > allyl-TrMOS > TMOS, if each precursor is reacted individually (homo-polymerization). Precursors show different hydrolysis rate when reacted together in the hybrid system than they are reacted individually. Cross-condensation products of TMOS and DMDMOS (QD) arise about 10 minutes of initiation of the reaction. The allyl-silica monolithic columns for capillary liquid chromatography can only be prepared in capillaries with 50 im internal diameter with acceptable performance. One of the most prominent problems related to the synthesis of silica monolithic structures is the volume shrinkage. The synthesis of allylfunctionalized silica hybrid monolithic structures has been studied in an attempt to reduce the volume shrinkage during aging, drying and heat treatment

  6. Liquid chromatographic determination of carbadox residues in animal feed.

    PubMed

    Roybal, J E; Munns, R K; Shimoda, W

    1985-01-01

    A liquid chromatographic (LC) method for determining residues of carbadox in the 0.01-10 ppm range in swine feed is described. Carbadox is extracted from ground feed with 25% acidified methanol-CHCl3, removed from emulsion-forming coextractables via an alumina column, separated from highly colored pigments by acid-base liquid-liquid partitioning, and finally isolated from interferences on a second alumina column. Isocratic reverse phase LC at 305 nm is used for quantitation. The average overall recovery at the 0.1, 0.5, and 1.0 ppm spike levels was 83.0% with a standard deviation of 2.04% and a coefficient of variation of 2.46%. PMID:4030635

  7. Liquid chromatographic determination of tetracycline residues in animal feeds.

    PubMed

    Martinez, E E; Shimoda, W

    1988-01-01

    A liquid chromatographic method for the multiresidue determination of tetracyclines (TCs) in feeds is described. The levels of quantitation were 10 ppm each for tetracycline-HCl (TC), oxytetracycline (OTC), and chlortetracycline-HCl (CTC); the detection limit was 40 ppb for each. The calibration curves were linear between 2.5 and 100 ppm. The procedure involved double extraction with pH 2.0 and pH 4.5 McIlvain buffers, cleanup on a Sephadex LH-20 column, separation on a Nova-Pak C18 column, and detection at 370 nm. Recoveries of 10 micrograms/g of each TC in multiresidue feed samples ranged from 55.8 to 75.5% for OTC, 71.6 to 100% for TC, and 22.4 to 60.6% for CTC. The identities of the TCs were confirmed by thin layer chromatography. PMID:3391942

  8. RAPID MEASUREMENTS OF NEPTUNIUM OXIDATION STATES USING CHROMATOGRAPHIC RESINS

    SciTech Connect

    Diprete, D; C Diprete, C; Mira Malek, M; Eddie Kyser, E

    2009-03-24

    The Savannah River Site's (SRS) H-Canyon facility uses ceric ammonium nitrate (CAN) to separate impure neptunium (Np) from a high sulfate feed stream. The material is processed using a two-pass solvent extraction purification which relies on CAN to oxidize neptunium to Np(VI) during the first pass prior to extraction. Spectrophotometric oxidation-state analyses normally used to validate successful oxidation to Np(VI) prior to extraction were compromised by this feed stream matrix. Therefore, a rapid chromatographic method to validate successful Np oxidation was developed using Eichrom Industries TRU and TEVA{reg_sign} resins. The method was validated and subsequently transferred to existing operations in the process analytical laboratories.

  9. Antibiofilm Properties of Acetic Acid

    PubMed Central

    Bjarnsholt, Thomas; Alhede, Morten; Jensen, Peter Østrup; Nielsen, Anne K.; Johansen, Helle Krogh; Homøe, Preben; Høiby, Niels; Givskov, Michael; Kirketerp-Møller, Klaus

    2015-01-01

    Bacterial biofilms are known to be extremely tolerant toward antibiotics and other antimicrobial agents. These biofilms cause the persistence of chronic infections. Since antibiotics rarely resolve these infections, the only effective treatment of chronic infections is surgical removal of the infected implant, tissue, or organ and thereby the biofilm. Acetic acid is known for its antimicrobial effect on bacteria in general, but has never been thoroughly tested for its efficacy against bacterial biofilms. In this article, we describe complete eradication of both Gram-positive and Gram-negative biofilms using acetic acid both as a liquid and as a dry salt. In addition, we present our clinical experience of acetic acid treatment of chronic wounds. In conclusion, we here present the first comprehensive in vitro and in vivo testing of acetic acid against bacterial biofilms. PMID:26155378

  10. Separation of two constituents from purple sweet potato by combination of silica gel column and high-speed counter-current chromatography.

    PubMed

    He, Kai; Ye, Xiaoli; Li, Xuegang; Chen, Hongying; Yuan, Lujiang; Deng, Yafei; Chen, Xin; Li, Xiaoduo

    2012-01-15

    It is known that the choice of solvent system for high speed counter-current chromatography separation is of utmost importance. In this study, a simple and rapid thin layer chromatograph coupling with fluorometric (TLC-F) method has been used to determine the partition coefficient of target compounds in HSCCC solvent system. Two components, 6,7-dimethoxycoumarin and 5-hydroxymethyl-2-furfural were successfully separated from purple sweet potato extracts by successive sample injection for the first time, using n-hexane-ethyl acetate-methanol-water (1:2:1:1, v/v/v/v) as the solvent system. Additionally, statistical analysis showed that there was no significant difference in partition coefficient obtained by the TLC-F method and by HPLC, which demonstrated the usefulness of TLC-F method. PMID:22197606

  11. How Much Can We Learn from a Single Chromatographic Experiment? A Bayesian Perspective.

    PubMed

    Wiczling, Paweł; Kaliszan, Roman

    2016-01-01

    In this work, we proposed and investigated a Bayesian inference procedure to find the desired chromatographic conditions based on known analyte properties (lipophilicity, pKa, and polar surface area) using one preliminary experiment. A previously developed nonlinear mixed effect model was used to specify the prior information about a new analyte with known physicochemical properties. Further, the prior (no preliminary data) and posterior predictive distribution (prior + one experiment) were determined sequentially to search towards the desired separation. The following isocratic high-performance reversed-phase liquid chromatographic conditions were sought: (1) retention time of a single analyte within the range of 4-6 min and (2) baseline separation of two analytes with retention times within the range of 4-10 min. The empirical posterior Bayesian distribution of parameters was estimated using the "slice sampling" Markov Chain Monte Carlo (MCMC) algorithm implemented in Matlab. The simulations with artificial analytes and experimental data of ketoprofen and papaverine were used to test the proposed methodology. The simulation experiment showed that for a single and two randomly selected analytes, there is 97% and 74% probability of obtaining a successful chromatogram using none or one preliminary experiment. The desired separation for ketoprofen and papaverine was established based on a single experiment. It was confirmed that the search for a desired separation rarely requires a large number of chromatographic analyses at least for a simple optimization problem. The proposed Bayesian-based optimization scheme is a powerful method of finding a desired chromatographic separation based on a small number of preliminary experiments. PMID:26607659

  12. HILIC separation mechanisms of tetracyclines on amino bonded silica column

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Effects of mobile phase variations on the chromatographic separation on amino bonded silica column in hydrophilic interaction chromatography (HILIC) were investigated for four zwitterionic tetracyclines (TCs): oxytetracycline, doxycycline, chlortetracycline and tetracycline. A mixed-mode retention m...

  13. Heterogeneous catalyst for the production of acetic anhydride from methyl acetate

    DOEpatents

    Ramprasad, Dorai; Waller, Francis Joseph

    1999-01-01

    This invention relates to a process for producing acetic anhydride by the reaction of methyl acetate, carbon monoxide, and hydrogen at elevated temperatures and pressures in the presence of an alkyl halide and a heterogeneous, bifunctional catalyst that contains an insoluble polymer having pendant quaternized phosphine groups, some of which phosphine groups are ionically bonded to anionic Group VIII metal complexes, the remainder of the phosphine groups being bonded to iodide. In contrast to prior art processes, no accelerator (promoter) is necessary to achieve the catalytic reaction and the products are easily separated from the catalyst by filtration. The catalyst can be recycled for consecutive runs without loss in activity. Bifunctional catalysts for use in carbonylating dimethyl ether are also provided.

  14. Heterogeneous catalyst for the production of acetic anhydride from methyl acetate

    DOEpatents

    Ramprasad, D.; Waller, F.J.

    1999-04-06

    This invention relates to a process for producing acetic anhydride by the reaction of methyl acetate, carbon monoxide, and hydrogen at elevated temperatures and pressures in the presence of an alkyl halide and a heterogeneous, bifunctional catalyst that contains an insoluble polymer having pendant quaternized phosphine groups, some of which phosphine groups are ionically bonded to anionic Group VIII metal complexes, the remainder of the phosphine groups being bonded to iodide. In contrast to prior art processes, no accelerator (promoter) is necessary to achieve the catalytic reaction and the products are easily separated from the catalyst by filtration. The catalyst can be recycled for consecutive runs without loss in activity. Bifunctional catalysts for use in carbonylating dimethyl ether are also provided.

  15. Chromatographic fingerprint analysis of Pycnogenol dietary supplements.

    PubMed

    Chen, Pei; Song, Fenhong; Lin, Long-Ze

    2009-01-01

    The bark of maritime pine (Pinus pinaster Aiton) has been widely used as a remedy for various degenerative diseases. A standard high-performance liquid chromatographic (HPLC) procedure for Pycnogenol analysis is a method specified in the United States Pharmacopeia (USP) monograph, which requires measurement of peak areas and identification of four components of the extract: caffeic acid, catechin, ferulic acid, and taxifolin. In this study, a fingerprint analysis using an HPLC method based on the USP monograph has been developed to provide additional qualitative information for the analysis of Pycnogenol-containing dietary supplements (PDS). Twelve commercially available PDS samples were purchased and analyzed along with a standard Pycnogenol extract. Their chromatographic fingerprints were analyzed using principal component analysis. The results showed that two of the samples were not consistent with the standard reference Pycnogenol extract. One contained other active ingredients in addition to Pycnogenol, and the other may have resulted from a quality control issue in manufacturing. PMID:19485224

  16. A nonlinear model for gas chromatograph systems

    NASA Technical Reports Server (NTRS)

    Feinberg, M. P.

    1975-01-01

    Fundamental engineering design techniques and concepts were studied for the optimization of a gas chromatograph-mass spectrometer chemical analysis system suitable for use on an unmanned, Martian roving vehicle. Previously developed mathematical models of the gas chromatograph are found to be inadequate for predicting peak heights and spreading for some experimental conditions and chemical systems. A modification to the existing equilibrium adsorption model is required; the Langmuir isotherm replaces the linear isotherm. The numerical technique of Crank-Nicolson was studied for use with the linear isotherm to determine the utility of the method. Modifications are made to the method eliminate unnecessary calculations which result in an overall reduction of the computation time of about 42 percent. The Langmuir isotherm is considered which takes into account the composition-dependent effects on the thermodynamic parameter, mRo.

  17. Micro-column plasma emission liquid chromatograph

    DOEpatents

    Gay, Don D.

    1984-01-01

    In a direct current plasma emission spectrometer for use in combination with a micro-column liquid chromatograph, an improved plasma source unit. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  18. Flow in a metal hydride chromatographic column

    SciTech Connect

    Nichols, G.S.

    1990-01-01

    The flow of hydrogen isotopes in a metal hydride chromatographic column is calculated by a one-dimensional finite difference method. The Ergun equation is used to define the gas flow; and equilibrium pressure isotherms are used to define the column holdup. Solid phase loadings are shown to move as a wave front on absorption, but remain more uniform on desorption. 3 refs., 4 figs.

  19. Development and validation of reversed-phase column high-performance liquid chromatographic and first-derivative UV spectrophotometric methods for estimation of voriconazole in oral suspension powder.

    PubMed

    Prajapati, Arun M; Patel, Satish A; Patel, Natvarlal J; Patel, Dipti B; Patel, Sejal K

    2008-01-01

    This research paper describes validated reversed-phase high-performance column liquid chromatographic (RP-HPLC) and first-derivative UV spectrophotometric methods for the estimation of voriconazole (VOR) in oral suspension powder. The RP-HPLC separation was achieved on Phenomenex C18 column (250 x 4.6 mm id, 5 microm particle size) using water-acetonitrile (40 + 60, v/v; pH adjusted to 4.5 +/- 0.02 with acetic acid) as the mobile phase at a flow rate of 1.4 mL/min and ambient temperature. Quantification was achieved with photodiode array detection at 255 nm over the concentration range of 0.1-1 microg/mL with mean recovery of 99.49 +/- 0.83% for VOR by the RP-HPLC method. Quantification was achieved with UV detection at 266 nm over the concentration range of 8-20 microg/mL with mean recovery of 99.74 +/- 0.664% for VOR by the first-derivative UV spectrophotometric method. These methods are simple, precise, and sensitive, and they are applicable for the determination of VOR in oral suspension powder. PMID:18980120

  20. High-performance liquid chromatographic resolution of reverse isomers of 1,2-diacyl-rac-glycerols as 3,5-dinitrophenylurethanes.

    PubMed

    Itabashi, Y; Myher, J J; Kuksis, A

    2000-10-01

    The resolution of reverse isomers remains a major unsolved problem in glycerolipid chromatography. We have investigated the separation of the reverse isomers of 1,2-diacyl-rac-glycerols under a variety of high-performance liquid chromatography (HPLC) conditions. The reverse isomers of diacylglycerols having various pairs of acyl groups including short and highly unsaturated chains, which were prepared by partial Grignard degradation of the corresponding triacylglycerols, were chromatographed as 3,5-dinitrophenylurethanes. Excellent resolution was achieved for the reverse isomers of very different pairs of acyl groups, such as acetate-palmitate and docosahexaenoate-palmitate, by chiral-phase HPLC on columns containing (R)- and (S)-1-(1-naphthyl)ethylamine polymeric phases, reversed-phase HPLC on a highly efficient C18 column (4 microm particle size) and silver ion HPLC on a silver loaded cation-exchange column. The chiral-phase HPLC also permitted complete enantiomer resolution for all the reverse isomers examined. No satisfactory resolution by any of the HPLC methods, however, was obtained for the reverse isomers possessing minor differences in chain lengths and degree of unsaturation, such as laurate-palmitate and oleate-linoleate. The limitations of resolution and characteristics of elution are described. PMID:11073297

  1. Limits of detections for the determination of mono- and dicarboxylic acids using gas and liquid chromatographic methods coupled with mass spectrometry

    PubMed Central

    Št’ávová, Jana; Beránek, Josef; Nelson, Eric P.; Diep, Bonnie A.; Kubátová, Alena

    2011-01-01

    The chromatographic separation and instrumental limits of detection (LODs) were obtained for a broad range of C1-C18 monocarboxylic (MCAs) and C2-C14 dicarboxylic acids (DCAs) employing either chemical derivatization followed by gas chromatography-mass spectrometry and flame ionization detection (GC-MS/FID) or direct analysis with liquid chromatography high resolution MS and tandem MS (LC-MS). Suitability, efficiency and stability of reaction products for several derivatization agents used for esterification (BF3/butanol), and trimethysilylation, including trimethylsilyl-N-N-dimethylcarbamate (TMSDMC) and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) were evaluated. The lowest limits of detection for the majority of compounds below 10 pg (with the exception of acetic acid) were obtained for derivatization with BF3/butanol followed by GC-MS in the total ion current (TIC) mode. Further improvements were achieved when applying either selected ion monitoring (SIM), which decreased the LODs to 1–4 pg or a combination of SIM and TIC (SITI) (2–5 pg). GC-FID provided LODs comparable to those obtained by GC-MS TIC. Both trimethylsilylation (followed by GC-MS) and direct LC-MS/MS analysis yielded LODs of 5– 40 pg for most of the acids. For volatile acids the LODs were higher, e.g., 25 and 590 ng for TMSDMC and BSTFA derivatized formic acid, respectively whereas the LC-MS methods did not allow for the analysis of formic acid at all. PMID:21185238

  2. Stereospecific determination of an HIV aspartyl protease inhibitor, PNU-103017, in rat, dog and human plasma using a Pirkle-concept high-performance liquid chromatographic column.

    PubMed

    Williams, M G; Zhong, W Z

    1997-06-20

    A sensitive stereospecific high-performance liquid chromatographic assay for the quantitation of the enantiomers of 4-cyano-N-(3-(cyclopropyl-(5,6,7,8,9,10-hexahydro-4-hydroxy-2-oxo-2H- cycloocta(b)pyran-3-yl)methyl)phenyl)benzenesulfonamide (PNU-103017) (I), an HIV protease inhibitor, in plasma of rat, dog and human was developed. The procedure involved an acetonitrile-aided protein precipitation followed by solid-phase extraction (SPE) of I from plasma into ethanol. Stereospecific separation was accomplished on a Pirkle-concept chiral column (Regis S,S-Whelk-01, 250x4.6 mm I.D.) with a mobile phase of absolute ethanol-0.1% acetic acid in hexane (30:70, v/v). The eluate was monitored by UV absorbance (295 nm). Linear calibration curves were obtained in the range of 0.2 to 500 microM, with a lower limit of quantitation of 0.1-0.2 microM for both enantiomers in either rat, dog or human plasma. Intra- and inter-assay precision and assay accuracy were demonstrated to be acceptable for the stereoselective pharmacokinetic analysis of I in plasma. PMID:9234860

  3. Chromatographic behaviour of steroidal saponins studied by high-performance liquid chromatography-mass spectrometry.

    PubMed

    Kite, Geoffrey C; Porter, Elaine A; Simmonds, Monique S J

    2007-05-01

    The chromatographic behaviour of steroidal saponins found in Anemarrhena asphodeloides, Asparagus officinalis, Convallaria majalis, Digitalis purpurea and Ruscus aculeatus was studied by HPLC-MS using a C-18 reversed-phase column and aqueous acetonitrile or aqueous methanol mobile phase gradients, with or without the addition of 1% acetic acid. The behaviour was compared to that of triterpene saponins found in Aesculus hippocastanum, Centella asiatica, Panax notoginseng and Potentilla tormentilla. Inclusion of methanol in the mobile phase under acidic conditions was found to cause furostanol saponins hydroxylated at C-22 to chromatograph as broad peaks, whereas the peak shapes of the spirostanol saponins and triterpene saponins studied remained acceptable. In aqueous methanol mobile phases without the addition of acid, furostanol saponins chromatographed with good peak shape, but each C-22 hydroxylated furostanol saponin was accompanied by a second chromatographic peak identified as its C-22 methyl ether. Methanolic extracts analysed in non-acidified aqueous acetonitrile mobile phases also resolved pairs of C-22 hydroxy and C-22 methoxy furostanol saponins. The C-22 methyl ether of deglucoruscoside was found to convert to deglucoruscoside during chromatography in acidified aqueous acetonitrile, or by dissolving in water. Poor chromatography of furostanol saponins in acidified aqueous methanol is due to the interconversion of the C-22 hydroxy and C-22 methoxy forms. It is recommended that initial analysis of saponins by HPLC-MS using a C-18 stationary phase is performed using acidified aqueous acetonitrile mobile phase gradients. The existence of naturally-occurring furostanol saponins methoxylated at C-22 can be investigated with aqueous acetonitrile mobile phases and avoiding methanol in the extraction solvent. PMID:17391684

  4. Chromatographic resolution of angiotensin II receptor antagonists (sartans).

    PubMed

    Tahir, Muhammad Saqlain; Adnan, Ahmad; Syed, Quratulain

    2016-08-01

    First time a simple, sensitive and unified quantification method has been developed to analyze the complete class of angiotensin II receptor antagonists which are used in the treatment of hypertension either alone or in combination with some other drugs. The most important advantage of developed method was that the eight separate drugs can be determined on a single chromatographic system without modifications in detection wavelength and mobile phase. The drugs were separated on a Purospher Star 4.6mm×25cm, 5μm, C18 column maintained at 40°C with 1mLmin(-1) flow rate using ultra violet detection at 254nm. Good separation (Rs>2.0) was achieved in a short analysis allowing simultaneous determination of all eight sartans. The effect of variation in flow rate, detection wavelength and column oven temperature was also studied. The proposed method was statistically validated in terms of precision, accuracy, linearity, specificity and robustness. The newly developed method proved to be specific, robust and accurate for the quantification of eight sartans in commercial pharmaceutical formulations. PMID:27258943

  5. Predicting the chromatographic retention of polymers: poly(methyl methacrylate)s and polyacryate blends.

    PubMed

    Bashir, Mubasher A; Radke, Wolfgang

    2007-09-01

    The suitability of a retention model especially designed for polymers is investigated to describe and predict the chromatographic retention behavior of poly(methyl methacrylate)s as a function of mobile phase composition and gradient steepness. It is found that three simple yet rationally chosen chromatographic experiments suffice to extract the analyte specific model parameters necessary to calculate the retention volumes. This allows predicting accurate retention volumes based on a minimum number of initial experiments. Therefore, methods for polymer separations can be developed in relatively short time. The suitability of the virtual chromatography approach to predict the separation of polymer blend is demonstrated for the first time using a blend of different polyacrylates. PMID:17586517

  6. Optimal operation of simulated moving bed chromatographic processes by means of simple feedback control.

    PubMed

    Schramm, Henning; Grüner, Stefan; Kienle, Achim

    2003-07-18

    In this contribution, simple methods are presented for controlling a simulated moving bed (SMB) chromatographic process with standard PI (proportional integral) controllers. The first method represents a simple and model-free inferential control scheme which was motivated from common distillation column control. The SMB unit is equipped with UV detectors. The UV signals in the four separation zones of the unit are fixed by four corresponding PI controllers calculating the ratio of liquid and solid flow in the respective separation zone. In order to be able to adjust the product purity a second, model-based control scheme is proposed. It makes use of the nonlinear wave propagation phenomena in the apparatus. The controlled chromatographic unit is automatically working with minimum solvent consumption and maximum feed throughput--without any numerical optimization calculations. This control algorithm can therefore also be applied for fast optimization of SMB processes. PMID:12938872

  7. LC-MS/MS determination of betamethasone and its phosphate and acetate esters in human plasma after sample stabilization.

    PubMed

    Salem, Isam I; Alkhatib, Musab; Najib, Naji

    2011-12-15

    Two specific liquid chromatography-mass spectrometric (LC-MS/MS) assays were developed and validated for the determination of betamethasone (BET), and its acetate (BA) and phosphate (BP) esters. The plasma and the blood used for the development and validation of these two methods were previously stabilized. Liquid-liquid extraction techniques were used after the addition of prednisolone as internal standard (IS). Samples were chromatographed using C8 column, while mass detection was carried out by electrospray ionization in the positive mode (ESI+). The method was proved linear over a working range 0.50-50.00 ng/ml for BET (r(2)>0.99), while BA linear range was 1.0-20.0 ng/ml (r(2)>0.99). Sensitivity was determined as 0.50 ng/ml for BET and 1.00 ng/ml for BA. Betamethasone phosphate LC-MS/MS method involved solid phase extraction after the addition of prednisolone phosphate as (IS). Separation was carried out using C18 column, while detection was by ESI+. The method showed good linearity over the working range 2.0-200.0 ng/ml (r(2)>099). Both methods were applied to determine BET, BA and BP in plasma samples obtained for pharmacokinetics studies in human. PMID:21855245

  8. Chromatographic determination of riboflavin and its derivatives in food.

    PubMed

    Gliszczyńska-Swigło, A; Koziołowa, A

    2000-06-01

    Three elution methods on two different reversed-phase C18 columns were developed to determine flavin derivatives in raw egg white, raw egg yolk, egg powder, pasteurised milk, fermented milk products and liver (chicken, calf and pig). Additionally, 11 thin-layer chromatography solvent systems were used to confirm presence of flavins detected in assessed products. It was found that an Alphabond C18 column was not as effective as a Symmetry C18 column. Method A (mobile phase gradient of methanol-0.05 M ammonium acetate, pH 6.0 applied on an Alphabond C18 column) can be used for determination of flavin adenine dinucleotide, flavin mononucleotide, riboflavin 4',5'-cyclic phosphate, riboflavin, 10-formylmethylflavin and 10-hydroxyethylflavin in products that do not contain 7alpha-hydroxyriboflavin. Method B (mobile phase gradient of methanol-demineralized water, on an Alphabond C18 column) can be useful to separate flavin coenzymes from other flavin compounds or to confirm the presence of 7alpha-hydroxyriboflavin and 10-hydroxyethylflavin in analysed samples. Method C (mobile phase gradient of methanol-0.05 M ammonium acetate, pH 6.0, on a Symmetry C18 column) allows separation of all flavins detected in tested products: flavin adenine dinucleotide, flavin mononucleotide, riboflavin 4',5'-cyclic phosphate, riboflavin, 10-formylmethylflavin, 10-hydroxyethylflavin, 7alpha-hydroxyriboflavin, riboflavin-beta-D-galactoside and riboflavin-alpha-D-glucoside. PMID:10905712

  9. The influence of mobile phase demixion on thin-layer chromatographic enantioseparation of ibuprofen and naproxen.

    PubMed

    Sajewicz, Mieczysław; Kaczmarski, Krzysztof; Gontarska, Monika; Kiszka, Sylwia; Kowalska, Teresa

    2007-09-01

    In our earlier article we presented the results of tracing the enantioseparation of the two test analytes (ibuprofen and naproxen) by means of video densitometry and scanning densitometry. In that way we demonstrated an excellent performance of this combined approach to the thin-layer chromatographic detection in the area of enantioseparation. In this paper we study an impact of the four different mobile phases on the enantioseparation of the scalemic mixtures of ibuprofen and naproxen on the silica gel layers impregnated with L-arginine as chiral selector. The main component of all the investigated mobile phases is 2-propanol. Mobile phase 1 consists of pure 2-propanol, while mobile phases 2-4 contain, respectively, ca. 0.66, 1.32, and 1.98 g/L of glacial acetic acid in 2-propanol. Acetic acid is used to protonate L-arginine, as the involved retention mechanism consists of the ion pair formation between L-arginine in the cationic form and the chiral 2-arylpropionic acids (2-APAs), ibuprofen and naproxen, in the anionic form. It is shown that in the absence of glacial acetic acid no enantioseparation can be obtained. Then with adding of 0.66 g/L glacial acetic acid partial enantioseparation of the naproxen and ibuprofen antimers is obtained, with a simultaneous effect of the mobile phase demixion. With the amount of acetic acid increasing, the effect of demixion becomes increasingly perceptible. In that case the displacement effect is observed (and mathematically modeled), which results in compressing of the antimer pairs by the second front of mobile phase. The obtained results allow a deeper insight into the mechanism of enantioseparation with the two test 2-APAs. A combined impact of the crystalline chirality of silica gel and the molecular chirality of L-arginine on the vertical and the horizontal enantioseparation of ibuprofen and naproxen is also discussed. PMID:18019559

  10. 21 CFR 184.1185 - Calcium acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Calcium acetate. 184.1185 Section 184.1185 Food and... Substances Affirmed as GRAS § 184.1185 Calcium acetate. (a) Calcium acetate (Ca (C2H3O2)2, CAS Reg. No. 62-54-4), also known as acetate of lime or vinegar salts, is the calcium salt of acetic acid. It may...

  11. Predictability of enantiomeric chromatographic behavior on various chiral stationary phases using typical reversed phase modeling software.

    PubMed

    Wagdy, Hebatallah A; Hanafi, Rasha S; El-Nashar, Rasha M; Aboul-Enein, Hassan Y

    2013-09-01

    Pharmaceutical companies worldwide tend to apply chiral chromatographic separation techniques in their mass production strategy rather than asymmetric synthesis. The present work aims to investigate the predictability of chromatographic behavior of enantiomers using DryLab HPLC method development software, which is typically used to predict the effect of changing various chromatographic parameters on resolution in the reversed phase mode. Three different types of chiral stationary phases were tested for predictability: macrocyclic antibiotics-based columns (Chirobiotic V and T), polysaccharide-based chiral column (Chiralpak AD-RH), and protein-based chiral column (Ultron ES-OVM). Preliminary basic runs were implemented, then exported to DryLab after peak tracking was accomplished. Prediction of the effect of % organic mobile phase on separation was possible for separations on Chirobiotic V for several probes: racemic propranolol with 97.80% accuracy; mixture of racemates of propranolol and terbutaline sulphate, as well as, racemates of propranolol and salbutamol sulphate with average 90.46% accuracy for the effect of percent organic mobile phase and average 98.39% for the effect of pH; and racemic warfarin with 93.45% accuracy for the effect of percent organic mobile phase and average 99.64% for the effect of pH. It can be concluded that Chirobiotic V reversed phase retention mechanism follows the solvophobic theory. PMID:23775938

  12. SEPARATION OF PLUTONYL IONS

    DOEpatents

    Connick, R.E.; McVey, Wm.H.

    1958-07-15

    A process is described for separating plutonyl ions from the acetate ions with which they are associated in certaln carrier precipitation methods of concentrating plutonium. The method consists in adding alkaline earth metal ions and subsequently alkalizing the solution, causing formation of an alkaltne earth plutonate precipitate. Barium hydroxide is used in a preferred embodiment since it provides alkaline earth metal ion and alkalizes the solution in one step forming insoluble barium platonate.

  13. METHOD OF SEPARATING PLUTONIUM

    DOEpatents

    Heal, H.G.

    1960-02-16

    BS>A method of separating plutonium from aqueous nitrate solutions of plutonium, uranium. and high beta activity fission products is given. The pH of the aqueous solution is adjusted between 3.0 to 6.0 with ammonium acetate, ferric nitrate is added, and the solution is heated to 80 to 100 deg C to selectively form a basic ferric plutonium-carrying precipitate.

  14. Development of Acetic Acid Removal Technology for the UREX+Process

    SciTech Connect

    Robert M. Counce; Jack S. Watson

    2009-06-30

    It is imperative that acetic acid is removed from a waste stream in the UREX+process so that nitric acid can be recycled and possible interference with downstreatm steps can be avoidec. Acetic acid arises from acetohydrozamic acid (AHA), and is used to suppress plutonium in the first step of the UREX+process. Later, it is hydrolyzed into hydroxyl amine nitrate and acetic acid. Many common separation technologies were examined, and solvent extraction was determined to be the best choice under process conditions. Solvents already used in the UREX+ process were then tested to determine if they would be sufficient for the removal of acetic acid. The tributyl phosphage (TBP)-dodecane diluent, used in both UREX and NPEX, was determined to be a solvent system that gave sufficient distribution coefficients for acetic acid in addition to a high separation factor from nitric acid.

  15. Myo-inositol esters of indole-3-acetic acid are endogenous components of Zea mays L. shoot tissue

    NASA Technical Reports Server (NTRS)

    Chisnell, J. R.

    1984-01-01

    Indole-3-acetyl-myo-inositol esters have been demonstrated to be endogenous components of etiolated Zea mays shoots tissue. This was accomplished by comparison of the putative compounds with authentic, synthetic esters. The properties compared were liquid and gas-liquid chromatographic retention times and the 70-ev mass spectral fragmentation pattern of the pentaacetyl derivative. The amount of indole-3-acetyl-myo-inositol esters in the shoots was determined to be 74 nanomoles per kilogram fresh weight as measured by isotope dilution, accounting for 19% of the ester indole-3-acetic acid of the shoot. This work is the first characterization of an ester conjugate of indole-3-acetate acid from vegetative shoot tissue using multiple chromatographic properties and mass spectral identification. The kernel and the seedling shoot both contain indole-3-acetyl-myo-inositol esters, and these esters comprise approximately the same percentage of the total ester content of the kernel and of the shoot.

  16. High-pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, C.G.; Sakaji, R.H.

    1982-09-08

    A gradient mixer effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum band-broadening.

  17. High pressure liquid chromatographic gradient mixer

    DOEpatents

    Daughton, Christian G.; Sakaji, Richard H.

    1985-01-01

    A gradient mixer which effects the continuous mixing of any two miscible solvents without excessive decay or dispersion of the resultant isocratic effluent or of a linear or exponential gradient. The two solvents are fed under low or high pressure by means of two high performance liquid chromatographic pumps. The mixer comprises a series of ultra-low dead volume stainless steel tubes and low dead volume chambers. The two solvent streams impinge head-on at high fluxes. This initial nonhomogeneous mixture is then passed through a chamber packed with spirally-wound wires which cause turbulent mixing thereby homogenizing the mixture with minimum "band-broadening".

  18. Development of Gas Chromatographic Mass Spectrometry.

    PubMed

    Hites, Ronald A

    2016-07-19

    Gas chromatographic mass spectrometry is now widely used for the quantitation and identification of organic compounds in almost any imaginable sample. These applications include the measurement of chlorinated dioxins in soil samples, the identification of illicit drugs in human blood, and the quantitation of accelerants in arson investigations, to name just a few. How did GC/MS get so popular? It turns out that it required parallel developments in mass spectrometry, gas chromatography, and computing and that no one person "invented" the technique. This Perspective traces this history from the 1950s until today. PMID:27384908

  19. Chromatographic method for determining fouling tendency of liquid hydrocarbons

    SciTech Connect

    Dickakian, G.B.

    1988-06-21

    A method is described for determining the tendency of a liquid hydrocarbon stream to foul equipment comprising the steps of: (a) depositing a sample of liquid hydrocarbon from a liquid hydrocarbon stream onto a surface of a thin film in the presence of an asphaltene antisolvent, wherein the thin film is made up of a chromatographic separation material; (b) letting the sample of liquid hydrocarbon migrate radially outward within the film for sufficient time so that hydrocarbon compatible fractions in the sample separate from any hydrocarbon-incompatible asphaltenes in the sample, wherein the hydrocarbon compatible fractions form a matrix portion in the film and any hydrocarbon-incompatible asphaltenes form a dark ring within the matrix portion and wherein any ring formed is disposed within a central region of the matrix portion and is distinguished from the matrix portion by a dark area having a boundary with respect to a lighter area; and (c) determining the tendency of the liquid hydrocarbon stream to fuel equipment by comparing the matrix portion with any dark ring formed from any hydrocarbon-incompatible asphaltenes in the sample, wherein the area and intensity of any ring formed in relation to the matrix portion provides an indication of the tendency of the liquid hydrocarbon stream to foul equipment.

  20. PROCESS FOR THE SEPARATION OF HEAVY METALS

    DOEpatents

    Gofman, J.W.; Connick, R.E.; Wahl, A.C.

    1959-01-27

    A method is presented for thc separation of plutonium from uranium and the fission products with which it is associated. The method is based on the fact that hexavalent plutonium forms an insoluble complex precipitate with sodium acetate, as does the uranyl ion, while reduced plutonium is not precipitated by sodium acetate. Several embodiments are shown, e.g., a solution containing plutonium and uranium in the hexavalent state may be contacted with sodium acetate causing the formation of a sodium uranyl acetate precipitate which carries the plutonium values while the fission products remain in solution. If the original solution is treated with a reducing agent, so that the plutonium is reduced while the uranium remains in the hexavalent state, and sodium and acetate ions are added, the uranium will precipitutc while the plutonium remains in solution effecting separation of the Pu from urarium.

  1. Desmopressin Acetate in Intracranial Haemorrhage

    PubMed Central

    Kapapa, Thomas; Röhrer, Stefan; Struve, Sabine; Petscher, Matthias; König, Ralph; Wirtz, Christian Rainer; Woischneck, Dieter

    2014-01-01

    Introduction. The secondary increase in the size of intracranial haematomas as a result of spontaneous haemorrhage or trauma is of particular relevance in the event of prior intake of platelet aggregation inhibitors. We describe the effect of desmopressin acetate as a means of temporarily stabilising the platelet function. Patients and Methods. The platelet function was analysed in 10 patients who had received single (N = 4) or multiple (N = 6) doses of acetylsalicylic acid and 3 patients (control group) who had not taken acetylsalicylic acid. All subjects had suffered intracranial haemorrhage. Analysis was performed before, half an hour and three hours after administration of desmopressin acetate. Statistical analysis was performed by applying a level of significance of P ≤ 0.05. Results. (1) Platelet function returned to normal 30 minutes after administration of desmopressin acetate. (2) The platelet function worsened again after three hours. (3) There were no complications related to electrolytes or fluid balance. Conclusion. Desmopressin acetate can stabilise the platelet function in neurosurgical patients who have received acetylsalicylic acid prior to surgery without causing transfusion-related side effects or a loss of time. The effect is, however, limited and influenced by the frequency of drug intake. Further controls are needed in neurosurgical patients. PMID:25610644

  2. Gas separation membranes

    DOEpatents

    Schell, William J.

    1979-01-01

    A dry, fabric supported, polymeric gas separation membrane, such as cellulose acetate, is prepared by casting a solution of the polymer onto a shrinkable fabric preferably formed of synthetic polymers such as polyester or polyamide filaments before washing, stretching or calendering (so called griege goods). The supported membrane is then subjected to gelling, annealing, and drying by solvent exchange. During the processing steps, both the fabric support and the membrane shrink a preselected, controlled amount which prevents curling, wrinkling or cracking of the membrane in flat form or when spirally wound into a gas separation element.

  3. Reductive opening of carbohydrate phenylsulfonylethylidene (PSE) acetals.

    PubMed

    Chéry, Florence; Cabianca, Elena; Tatibouët, Arnaud; De Lucchi, Ottorino; Lindhorst, Thisbe K; Rollin, Patrick

    2015-11-19

    The phenylsulfonylethylidene (PSE) acetal is a relatively new protecting group in carbohydrate chemistry. However, carbohydrate-derived phenylsulfonylethylidene (PSE) acetals show a different behavior in reductive desulfonylation than simple symmetrical acetals. Here we have investigated various SET-type reaction conditions in order to open PSE acetals regioselectively and to produce chiral ω-hydroxyethenyl ethers. Whereas sodium amalgam leads to a mixture of regioisomeric vinyl ethers besides the ethylidene acetal, samarium iodide is suited for regioselective ring opening. This is shown with seven different carbohydrate PSE acetals, both of the 1,3-dioxane and the 1,3-dioxolane type. PMID:26469209

  4. Evaluation of selectivity in homologous multimodal chromatographic systems using in silico designed antibody fragment libraries.

    PubMed

    Karkov, Hanne Sophie; Woo, James; Krogh, Berit Olsen; Ahmadian, Haleh; Cramer, Steven M

    2015-12-24

    This study describes the in silico design, surface property analyses, production and chromatographic evaluations of a diverse set of antibody Fab fragment variants. Based on previous findings, we hypothesized that the complementarity-determining regions (CDRs) constitute important binding sites for multimodal chromatographic ligands. Given that antibodies are highly diversified molecules and in particular the CDRs, we set out to examine the generality of this result. For this purpose, four different Fab fragments with different CDRs and/or framework regions of the variable domains were identified and related variants were designed in silico. The four Fab variant libraries were subsequently generated by site-directed mutagenesis and produced by recombinant expression and affinity purification to enable examination of their chromatographic retention behavior. The effects of geometric re-arrangement of the functional moieties on the multimodal resin ligands were also investigated with respect to Fab variant retention profiles by comparing two commercially available multimodal cation-exchange ligands, Capto MMC and Nuvia cPrime, and two novel multimodal ligand prototypes. Interestingly, the chromatographic data demonstrated distinct selectivity trends between the four Fab variant libraries. For three of the Fab libraries, the CDR regions appeared as major binding sites for all multimodal ligands. In contrast, the fourth Fab library displayed a distinctly different chromatographic behavior, where Nuvia cPrime and related multimodal ligand prototypes provided markedly improved selectivity over Capto MMC. Clearly, the results illustrate that the discriminating power of multimodal ligands differs between different Fab fragments. The results are promising indications that multimodal chromatography using the appropriate multimodal ligands can be employed in downstream bioprocessing for challenging selective separation of product related variants. PMID:26654254

  5. Adsorptive Membranes vs. Resins for Acetic Acid Removal from Biomass Hydrolysates

    SciTech Connect

    Han, B.; Carvalho, W.; Canilha, L.; da Silva, S. S.; e Silva, J. B. A.; McMillan, J. D.; Wickramasinghe, S. R.

    2006-01-01

    Acetic acid is a compound commonly found in hemicellulosic hydrolysates. This weak acid strongly influences the bioconversion of sugar containing hydrolysates. Previous investigators have used anion exchange resins for acetic acid removal from different hemicellulosic hydrolysates. In this study, the efficiency of an anion exchange membrane was compared to that of an anion exchange resin, for acetic acid removal from a DI water solution and an acidic hemicellulose hydrolysate pretreated using two different methods. Ion exchange membranes and resins have very different geometries. Here the performance of membranes and resins is compared using two dimensionless parameters, the relative mass throughput and chromatographic bed number. The relative mass throughput arises naturally from the Thomas solution for ion exchange. The results show that the membrane exhibit better performance in terms of capacity, and loss of the desired sugars. In addition acetic acid may be eluted at a higher concentration from the membrane thus leading to the possibility of recovery and re-use of the acetic acid.

  6. LC-PDA and LC-ESI-MS separation and determination of process-related substances arising from stilbene-type fluorescent whitening agents. Application to monitoring of their photodegradation products in industrial effluents and aqueous environmental systems.

    PubMed

    Rao, R Nageswara; Venkateswarlu, N; Khalid, Sara; Narsimha, R

    2005-03-01

    A simple and rapid gradient elution high-performance liquid chromatographic method using photodiode array and electrospray ionization mass spectrometric detectors was developed for separation and determination of the process-related substances and photodegradation products of stilbenesulfonic acids, viz. 4,4'-dinitrostilbene-2,2'-disulfonic acid (DNSDA), 4-amino-4'-nitrostilbene-2,2'-disulfonic acid (ANSDA), and 4,4'-diaminostilbene-2,2'-disulfonic acid (DASDA) in industrial waste waters. Gradient elution was carried out using ammonium acetate and acetonitrile as mobile phase and an Inertsil-ODS 3V column for separation. The negative-ion electrospray ionization mass spectra containing [M-H]- ions of sulfonic acids allowed molecular mass determination of unknowns and the structures were proposed on the basis of the fragment ions in the MS/MS spectra. PMID:15835732

  7. Liquid chromatographic determination of oxfendazole in swine feeds.

    PubMed

    Shah, G; Bradley, D; Shek, E

    1984-01-01

    A relatively simple analytical method is presented for determination of oxfendazole (2-(methoxycarbonylamino)-5-phenylsulfinyl-benzimidazole) at levels as low as 0.012% in swine feeds, using cation exchange liquid chromatography (LC). The sample was extracted with a solvent mixture of methanol-glacial acetic acid (90 + 10) at 45 degrees C, using a gyrorotory shaker. Plant pigments and other feed excipients were removed using zinc acetate treatment and pH-controlled extraction. Oxfendazole was further separated from the remaining interferences and quantitatively determined by LC on a Partisil SCX column with acetonitrile-0.01M phosphate buffer as mobile phase. The method is stability-specific, linear, precise, and accurate at 80-120% labeled strength (relative standard deviation 0.9-1.7 with mean recovery of 98-99%). Supporting data at a level of 0.0135% oxfendazole in swine feed indicated that this method is capable of complete recovery of oxfendazole from medicated swine feeds. PMID:6469900

  8. Introduction to time-of-flight secondary ion mass spectrometry application in chromatographic analysis.

    PubMed

    Orinák, Andrej; Arlinghaus, Heinrich F; Vering, Guido; Orináková, Renáta; Hellweg, Sebastian

    2005-08-19

    New on-line analytical system coupling thin layer chromatography (TLC) and high selective identification unit-time of flight secondary ion mass spectrometry (TOF-SIMS) is introduced in this article. Chromatographic mixture separation and analyte surface deposition followed with surface TOF-SIMS analysis on-line allows to identify the analytes at trace and ultratrace levels. The selected analytes with different detectability and identification possibility were analysed in this hyphenated unit (Methyl Red indicator, Terpinolen and Giberrelic acid). Here, the chromatographic thin layer plays a universal role: separation unit, analyte depositing surface and TOF-SIMS interface, finally. Two depositing substrates and TOF-SIMS compatible interfaces were tested in above-mentioned interfacing unit: modified aluminium backed chromatographic thin layer and monolithic silica thin layer. The sets of positive and negative ions TOF-SIMS spectra obtained from different SIMS modes of analysis were used for analyte identification purposes. SIMS enables analyte detection with high mass resolution at the concentration level that is not achieved by other methods. PMID:16114244

  9. Gas chromatograph-combustion system for 14C-accelerator mass spectrometry.

    PubMed

    McIntyre, Cameron P; Sylva, Sean P; Roberts, Mark L

    2009-08-01

    A gas chromatograph-combustion (GC-C) system is described for the introduction of samples as CO(2) gas into a (14)C accelerator mass spectrometry (AMS) system with a microwave-plasma gas ion source. Samples are injected into a gas chromatograph fitted with a megabore capillary column that uses H(2) as the carrier gas. The gas stream from the outlet of the column is mixed with O(2) and Ar gas and passed through a combustion furnace where the H(2) carrier gas and separated components are quantitatively oxidized to CO(2) and H(2)O. Water vapor is removed using a heated nafion dryer. The Ar carries the CO(2) to the ion source. The system is able to separate and oxidize up to 10 microg of compound and transfer the products from 7.6 mL/min of H(2) carrier gas into 0.2-1.0 mL/min of Ar carrier gas. Chromatographic performance and isotopic fidelity satisfy the requirements of the (14)C-AMS system for natural abundance measurements. The system is a significant technical advance for GC-AMS and may be capable of providing an increase in sensitivity for other analytical systems such as an isotope-ratio-monitoring GC/MS. PMID:19572555

  10. 21 CFR 522.533 - Deslorelin acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Deslorelin acetate. (a) Specifications. Each implant contains 2.1 milligrams deslorelin acetate. (b) Sponsor.... One implant per mare. (ii) Indications for use. For inducing ovulation within 48 hours in...

  11. Ozone decomposition in aqueous acetate solutions

    SciTech Connect

    Sehested, K.; Holcman, J.; Bjergbakke, E.; Hart, E.J.

    1987-01-01

    The acetate radical ion reacts with ozone with a rate constant of k = (1.5 +/- 0.5) x 10Z dmT mol s . The products from this reaction are CO2, HCHO, and O2 . By subsequent reaction of the peroxy radical with ozone the acetate radical ion is regenerated through the OH radical. A chain decomposition of ozone takes place. It terminates when the acetate radical ion reacts with oxygen forming the unreactive peroxy acetate radical. The chain is rather short as oxygen is developed, as a result of the ozone consumption. The inhibiting effect of acetate on the ozone decay is rationalized by OH scavenging by acetate and successive reaction of the acetate radical ion with oxygen. Some products from the bimolecular disappearance of the peroxy acetate radicals, however, react further with ozone, reducing the effectiveness of the stabilization.

  12. The Key to Acetate: Metabolic Fluxes of Acetic Acid Bacteria under Cocoa Pulp Fermentation-Simulating Conditions

    PubMed Central

    Adler, Philipp; Frey, Lasse Jannis; Berger, Antje; Bolten, Christoph Josef; Hansen, Carl Erik

    2014-01-01

    Acetic acid bacteria (AAB) play an important role during cocoa fermentation, as their main product, acetate, is a major driver for the development of the desired cocoa flavors. Here, we investigated the specialized metabolism of these bacteria under cocoa pulp fermentation-simulating conditions. A carefully designed combination of parallel 13C isotope labeling experiments allowed the elucidation of intracellular fluxes in the complex environment of cocoa pulp, when lactate and ethanol were included as primary substrates among undefined ingredients. We demonstrate that AAB exhibit a functionally separated metabolism during coconsumption of two-carbon and three-carbon substrates. Acetate is almost exclusively derived from ethanol, while lactate serves for the formation of acetoin and biomass building blocks. Although this is suboptimal for cellular energetics, this allows maximized growth and conversion rates. The functional separation results from a lack of phosphoenolpyruvate carboxykinase and malic enzymes, typically present in bacteria to interconnect metabolism. In fact, gluconeogenesis is driven by pyruvate phosphate dikinase. Consequently, a balanced ratio of lactate and ethanol is important for the optimum performance of AAB. As lactate and ethanol are individually supplied by lactic acid bacteria and yeasts during the initial phase of cocoa fermentation, respectively, this underlines the importance of a well-balanced microbial consortium for a successful fermentation process. Indeed, AAB performed the best and produced the largest amounts of acetate in mixed culture experiments when lactic acid bacteria and yeasts were both present. PMID:24837393

  13. A rapid paper chromatographic method for detection of anionic detergent in milk.

    PubMed

    Barui, Amit K; Sharma, Rajan; Rajput, Yudhishthir S; Singh, Smita

    2013-08-01

    A paper chromatographic method for the detection of adulteration of anionic detergent in milk is described. The method is based on the complexing of anionic detergent with methylene blue dye and separation of complex from free dye using simple paper chromatographic method. Since complexing of detergent is with dye, visualization is direct without involvement of subsequent detection of complex. The method is simple and results are available in 10 min. The method is sensitive to detect 0.1 % (w/v) labolene (laboratory grade detergent) or 0.01 % (w/v) sodium dodecylbenzene sulfonate (pure anionic detergent) in milk. The method can be adopted at quality control laboratories in dairies for ascertaining the quality of milk. PMID:24425989

  14. Enhanced extraction yields and mobile phase separations by solvent mixtures for the analysis of metabolites in Annona muricata L. leaves.

    PubMed

    Ribeiro de Souza, Eloana Benassi; da Silva, Renata Reis; Afonso, Sabrina; Scarminio, Ieda Spacino

    2009-12-01

    The effects of five extraction solvents and their mixtures on the yield of metabolites in crude and fractionated extracts of Annona muricata L. leaves were investigated by direct comparison. Extraction media were prepared using simplex centroid mixtures of ethanol, ethyl acetate, dichloromethane, acetone, and chloroform. The effects of the mobile phase solvent strength and the analysis wavelength on the chromatographic separation were also investigated. Solvent mixtures rather than pure solvents were found to be the most efficient extractors for the different fractions. The results indicated that the mobile phase composed of methanol/acetonitrile/water (26:27:47 v/v/v) was most suitable for the basic fraction analysis at 254 nm, whereas the mobile phase composed of methanol/acetonitrile/water (35:35:30 v/v/v) was the most adequate for the organic fraction analysis at 254 nm. The results indicated that the chromatographic profiles and number of peaks were affected by the mobile phase strength and analysis wavelength. PMID:19882621

  15. Selectivity and sensitivity of some thin-layer chromatographic detection systems.

    PubMed

    Fodor-Csorba, K; Dutka, F

    1986-09-19

    The selectivity and sensitivity of some thin-layer chromatographic detection systems widely used internationally and developed in our laboratory were studied. Halogenated organophosphorus pesticides were found to interfere with the detection of organochlorine pesticides when using silver nitrate-2-phenoxyethanol. The stability of colours formed by the 4-(4'-nitrobenzyl)pyridine-tetraethylenepentamine system was enhanced by spraying with acetic acid and allowed densitometric evaluation. The most sensitive detection method for thiocarbamates is the reaction with 2,6-dichlorobenzoquinone-N-chloroimine or its dibromo analogue (50 ng). Application of this method for sulphur-containing organophosphorus insecticides results in the same or better sensitivity. Quantitation of these compounds was carried out by densitometry. PMID:3771705

  16. Gas chromatographic determination of polysaccharide gums in foods after hydrolysis and derivatization.

    PubMed

    Lawrence, J F; Iyengar, J R

    1985-12-20

    A gas chromatographic method was evaluated for the determination of food grade gums in dairy products, salad dressings and meat sauces. The gums studied were tragacanth, karaya, ghatti, carob, guar, arabic and xanthan gum. The extraction method included removal of fat followed by starch degradation then precipitation of protein. The isolated gums were hydrolysed with trifluoroacetic acid and the resulting neutral monosaccharides converted to their aldonitrile acetate derivatives for determination by gas chromatography. Recoveries from thirteen different commodities averaged 85%. However, the recovery of guar gum from ice cream and cold pack cheese was 42 and 50%, respectively. In a comparison of enzyme hydrolysis and iodine complexation for the removal of starch the former was simpler and provided cleaner extracts than the iodine treatment. Both gave similar results. PMID:4093481

  17. 21 CFR 184.1721 - Sodium acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Sodium acetate. 184.1721 Section 184.1721 Food and....1721 Sodium acetate. (a) Sodium acetate (C2H3O2Na, CAS Reg. No. 127-09-3 or C2H3O2Na·3H2O, CAS Reg. No. 6131-90-4) is the sodium salt of acetic acid and occurs naturally in plant and animal tissues....

  18. Improving Hydrocarbon Separation In Gas Chromatography

    NASA Technical Reports Server (NTRS)

    Pollock, G. E.; Woeller, F.; Kojiro, D. R.

    1983-01-01

    Modified solica spheres enhance chromatographic separation. Commercially available silica spheres are modified by reacting them with molecules containing isocyante and isothiocyanate groups. Applications of surface derivatized spheres that result from reaction include analysis of samples prouced by atmospheric or soil probes.

  19. FIELD COMPARISON OF PORTABLE GAS CHROMATOGRAPHS WITH METHOD TO-14

    EPA Science Inventory

    A field-deployable prototype fast gas chromatograph (FGC) and two commercially-available portable gas chromatographs (PGC) were evaluated by measuring organic vapors in ambient air at a field monitoring site in metropolitan San Juan, Puerto Rico. he data were compared with simult...

  20. Gas-Chromatographic Determination Of Water In Freon PCA

    NASA Technical Reports Server (NTRS)

    Melton, Donald M.

    1994-01-01

    Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

  1. Kinetics of the Methanogenic Fermentation of Acetate

    PubMed Central

    Fukuzaki, Satoshi; Nishio, Naomichi; Nagai, Shiro

    1990-01-01

    Inhibition of the fermentation of acetate to methane and carbon dioxide by acetate was analyzed with an acetate-acclimatized sludge and with Methanosarcina barkeri Fusaro under mesophilic conditions. A second-order substrate inhibition model, qch4 = qmS/[Ks + S + (S2/Ki)], where S was the concentration of undissociated acetic acid, not ionized acetic acid, could be applicable in both cases. The analysis resulted in substrate saturation constants, Ks, of 4.0 μM for the acclimatized sludge and 104 μM for M. barkeri. The threshold concentrations of undissociated acetic acid when no further acetate utilization was observed were 0.078 μM (pH 7.50) for the acclimatized sludge and 4.43 μM (pH 7.45) for M. barkeri. These kinetic results suggested that the concentration of undissociated acetic acid became a key factor governing the actual threshold acetate concentration for acetate utilization and that the acclimatized sludge in which Methanothrix spp. appeared dominant could utilize acetate better and survive at a lower concentration of undissociated acetic acid than could M. barkeri. Images PMID:16348323

  2. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  3. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  4. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  5. 21 CFR 522.2476 - Trenbolone acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... days. (A) 140 milligrams (mg) trenbolone acetate (one implant consisting of 7 pellets, each pellet containing 20 mg trenbolone acetate) per implant dose. (B) 140 mg trenbolone acetate (one implant consisting... 29 mg tylosin tartrate) per implant dose. (ii) Indications for use. For improved feed...

  6. 21 CFR 582.6185 - Calcium acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Calcium acetate. 582.6185 Section 582.6185 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Calcium acetate. (a) Product. Calcium acetate. (b) Conditions of use. This substance is...

  7. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  8. 21 CFR 184.1005 - Acetic acid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Acetic acid. 184.1005 Section 184.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) DIRECT FOOD....1005 Acetic acid. (a) Acetic acid (C2H4O2, CAS Reg. No. 64-19-7) is known as ethanoic acid. It...

  9. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  10. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  11. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  12. 21 CFR 582.1005 - Acetic acid.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Acetic acid. 582.1005 Section 582.1005 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1005 Acetic acid. (a) Product. Acetic acid. (b) Conditions of use. This substance is...

  13. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  14. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  15. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  16. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  17. 21 CFR 582.1721 - Sodium acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Sodium acetate. 582.1721 Section 582.1721 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1721 Sodium acetate. (a) Product. Sodium acetate. (b) Conditions of use. This substance is...

  18. The stable carbon isotope biogeochemistry of acetate and methane in freshwater environments

    SciTech Connect

    Gelwicks, J.T.

    1989-01-01

    Methane produced in freshwater sediments, where acetate is the major substrate utilized by methanogenic bacteria, is commonly depleted in {sup 13}C. Variations in the carbon-isotopic composition of methane have been related to flows of acetate carbon to various fates within microbial communities. To examine these processes, the isotopic compositions of biogenic methane and its sedimentary sources (acetate and CO{sub 2}) were considered along with related isotope effects. A method of preparation for carbon isotope analyses of both carbons in acetate was developed. Uncertainties in measurements are less than 0.4{per thousand} for samples greater than 5 {mu}mol of acetate. Advantages of this technique include good separation of acetate from other compounds and the applicability to samples containing micromolar quantities of acetate. Carbon kinetic isotope effects associated with synthesis of acetate from CO{sub 2} by Acetobacterium woodii were measured by isotopic analyses of CO{sub 2}, methyl-carbon, and total acetate. Closed systems allowing construction of complete mass balances at varying stages of growth were utilized, and the effects of the partitioning of carbon between CO{sub 2} and HCO{sub 3}{sup {minus}} were taken into account. For the overall reaction total carbonate {yields} total acetate, the isotope effect measured {minus}58.6 {plus minus} 0.7{per thousand}; there is no evidence for intramolecular isotopic ordering in the acetate. Carbon isotope effects associated with synthesis of methane from acetate by Methanosarcina barkeri and by a natural community of methanogens were measured in closed system experiments. For the process of methyl-carbon {yields} methane, the isotope effect measured {minus}21.5 {plus minus} 1.3{per thousand}.

  19. Acet-oxy-γ-valerolactone.

    PubMed

    Tristram, Cameron; Gainsford, Graeme J; Hinkley, Simon

    2013-06-01

    Levulinyl cellulose esters have been produced as an effective renewable binder for architectural coatings. The title compound, C7H10O4 (systematic name: 2-methyl-5-oxo-tetra-hydro-furan-2-yl acetate), assigned as the esterifying species, was isolated and crystallized to confirm the structure. In the crystal, the mol-ecules pack in layers parallel to (102) utilizing weak C-H⋯O inter-actions. PMID:23795112

  20. Gas Chromatographic Detectors for Exobiology Flight Experiments

    NASA Technical Reports Server (NTRS)

    Kojiro, Daniel R.; Humphry, Donald E.; Takeuchi, Nori; Chang, Sherwood (Technical Monitor)

    1997-01-01

    Exobiology flight experiments require highly sensitive instrumentation for in situ chemical analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. Future missions to Mars', comets, or planetary moons such as Europa, will perform experiments with complex analyses. In addition, instrumentation for such missions must perform under severely restricted conditions with limited resources. To meet these analytical requirements, improved methods and highly sensitive yet smaller instruments must continually be developed with increasingly greater capabilities. We describe here efforts to achieve this objective, for past and future missions, through the development of new or the improvement of existing sensitive, miniaturized gas chromatographic detectors.

  1. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, Brian D.; Fought, Eric R.

    1989-01-01

    A moving belt interface for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer.

  2. Interface for liquid chromatograph-mass spectrometer

    DOEpatents

    Andresen, B.D.; Fought, E.R.

    1989-09-19

    A moving belt interface is described for real-time, high-performance liquid chromatograph (HPLC)/mass spectrometer (MS) analysis which strips away the HPLC solvent as it emerges from the end of the HPLC column and leaves a residue suitable for mass-spectral analysis. The interface includes a portable, stand-alone apparatus having a plural stage vacuum station, a continuous ribbon or belt, a drive train magnetically coupled to an external drive motor, a calibrated HPLC delivery system, a heated probe tip and means located adjacent the probe tip for direct ionization of the residue on the belt. The interface is also capable of being readily adapted to fit any mass spectrometer. 8 figs.

  3. Multiscale peak alignment for chromatographic datasets.

    PubMed

    Zhang, Zhi-Min; Liang, Yi-Zeng; Lu, Hong-Mei; Tan, Bin-Bin; Xu, Xiao-Na; Ferro, Miguel

    2012-02-01

    Chromatography has been extensively applied in many fields, such as metabolomics and quality control of herbal medicines. Preprocessing, especially peak alignment, is a time-consuming task prior to the extraction of useful information from the datasets by chemometrics and statistics. To accurately and rapidly align shift peaks among one-dimensional chromatograms, multiscale peak alignment (MSPA) is presented in this research. Peaks of each chromatogram were detected based on continuous wavelet transform (CWT) and aligned against a reference chromatogram from large to small scale gradually, and the aligning procedure is accelerated by fast Fourier transform cross correlation. The presented method was compared with two widely used alignment methods on chromatographic dataset, which demonstrates that MSPA can preserve the shapes of peaks and has an excellent speed during alignment. Furthermore, MSPA method is robust and not sensitive to noise and baseline. MSPA was implemented and is available at http://code.google.com/p/mspa. PMID:22222564

  4. Detection system for a gas chromatograph

    DOEpatents

    Hayes, John M.; Small, Gerald J.

    1984-01-01

    A method and apparatus are described for the quantitative analysis of vaporizable compounds, and in particular of polycyclic aromatic hydrocarbons which may be induced to fluoresce. The sample to be analyzed is injected into a gas chromatography column and is eluted through a narrow orifice into a vacuum chamber. The free expansion of the eluted sample into the vacuum chamber creates a supersonic molecular beam in which the sample molecules are cooled to the extent that the excited vibrational and rotational levels are substantially depopulated. The cooled molecules, when induced to fluoresce by laser excitation, give greatly simplified spectra suitable for analytical purposes. The laser induced fluorimetry provides great selectivity, and the gas chromatograph provides quantitative transfer of the sample to the molecular beam.

  5. FTIR gas chromatographic analysis of perfumes

    NASA Astrophysics Data System (ADS)

    Diederich, H.; Stout, Phillip J.; Hill, Stephen L.; Krishnan, K.

    1992-03-01

    Perfumes, natural or synthetic, are complex mixtures consisting of numerous components. Gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) techniques have been extensively utilized for the analysis of perfumes and essential oils. A limited number of perfume samples have also been analyzed by FT-IR gas chromatographic (GC-FTIR) techniques. Most of the latter studies have been performed using the conventional light pipe (LP) based GC-FTIR systems. In recent years, cold-trapping (in a matrix or neat) GC-FTIR systems have become available. The cold-trapping systems are capable of sub-nanogram sensitivities. In this paper, comparison data between the LP and the neat cold-trapping GC- FTIR systems is presented. The neat cold-trapping interface is known as Tracer. The results of GC-FTIR analysis of some commercial perfumes is also presented. For comparison of LP and Tracer GC-FTIR systems, a reference (synthetic) mixture containing 16 major and numerous minor constituents was used. The components of the mixture are the compounds commonly encountered in commercial perfumes. The GC-FTIR spectra of the reference mixture was obtained under identical chromatographic conditions from an LP and a Tracer system. A comparison of the two sets of data thus generated do indeed show the enhanced sensitivity level of the Tracer system. The comparison also shows that some of the major components detected by the Tracer system were absent from the LP data. Closer examination reveals that these compounds undergo thermal decomposition on contact with the hot gold surface that is part of the LP system. GC-FTIR data were obtained for three commercial perfume samples. The major components of these samples could easily be identified by spectra search against a digitized spectral library created using the Tracer data from the reference mixture.

  6. Factors affecting acetic acid production by yeasts in strongly clarified grape musts.

    PubMed

    Moruno, E G; Delfini, C; Pessione, E; Giunta, C

    1993-01-01

    High acetate content in a wine, after strong clarification of the must, is due to depletion in the yeast cells of important metabolites (normally present in non-clarified musts) such as metals, amino acids, polyphenolic compounds and unsaturated fatty acids. These substances were added separately to a synthetic medium, comparable in composition to the clarified must, which was then inoculated with a high acetate producer strain. No effects were observed after the addition of various metals and amino acids. The addition of unsaturated fatty acids (Tween 80) caused a significant (p = 0.01) decrease in acetate content. Similar results have been obtained in the presence of polyphenols (catechins and anthocyans): their mechanism of action is probably due to direct inhibition of the enzyme aldehyde dehydrogenase. Control experiments were performed with a low acetate producer strain, and a reduction in acetate content was detected. No differences in the glyceropyruvic metabolism of the two strains was evident. PMID:8366831

  7. Preconcentration procedures for phthalate esters combined with chromatographic analysis.

    PubMed

    Lv, Xueju; Hao, Yi; Jia, Qiong

    2013-08-01

    Phthalate esters are endocrine disrupters or mutagens. They are widely used as plasticizers and can be usually found in environmental samples, such as food, soil and polluted air. However, it is difficult to directly determine phthalate esters owing to their relatively low concentration and complex matrices. Therefore, preconcentration and separation have become increasingly important. In recent years, many preconcentration methods have been successfully developed and widely used, such as liquid-liquid extraction, dispersive liquid-liquid microextraction and solid-phase extraction. These preconcentration methods for phthalate esters can be applied to various real samples, water, soil, air, food and cosmetics. The aim of this paper is to review recent literature studies (primarily from the last five years) about preconcentration techniques for phthalate esters coupled with chromatographic analysis. The following text describes several preconcentration approaches, including liquid-liquid extraction, dispersive liquid-liquid microextraction, cloud point extraction, solid-phase extraction, solid-phase microextraction and stir bar sorptive extraction. Their advantages and disadvantages are also summarized. PMID:23696389

  8. Sequential injection chromatographic determination of ambroxol hydrochloride and doxycycline in pharmaceutical preparations.

    PubMed

    Satínský, Dalibor; Santos, Lucia M L Dos; Sklenárová, Hana; Solich, Petr; Montenegro, M Conceição B S M; Araújo, Alberto N

    2005-12-15

    A new separation method based on a novel reversed-phase sequential injection chromatography (SIC) technique was used for simultaneous determination of ambroxol hydrochloride and doxycycline in pharmaceutical preparations in this contribution. The coupling of short monolith with SIA system results in an implementation of separation step to until no-separation low-pressure method. A Chromolith((R)) Flash RP-18e, 25-4.6mm column (Merck, Germany) and a FIAlab((R)) 3000 system (USA) with a six-port selection valve and 5ml syringe were used for sequential injection chromatographic separations in our study. The mobile phase used was acetonitrile-water (20:90, v/v), pH 2.5 adjusted with 98% phosphoric acid, flow rate 0.48mlmin(-1), UV detection was at 213nm. The validation parameters have shown good results: linearity of determination for both compounds including internal standard (ethylparaben) >0.999; repeatability of determination (R.S.D.) in the range 0.5-5.4% at three different concentration levels, detection limits in the range 0.5-2.0mugml(-1), and recovery from the pharmaceutical preparation in the range 99.3-99.9%. The chromatographic resolution between peak compounds was >5.0 and analysis time was <9min under the optimal conditions. The method was found to be applicable for routine analysis of the active compounds ambroxol hydrochloride and doxycycline in various pharmaceutical preparations. PMID:18970307

  9. Identification and phylogeny of Arabian snakes: Comparison of venom chromatographic profiles versus 16S rRNA gene sequences.

    PubMed

    Al Asmari, Abdulrahman; Manthiri, Rajamohammed Abbas; Khan, Haseeb Ahmad

    2014-11-01

    Identification of snake species is important for various reasons including the emergency treatment of snake bite victims. We present a simple method for identification of six snake species using the gel filtration chromatographic profiles of their venoms. The venoms of Echis coloratus, Echis pyramidum, Cerastes gasperettii, Bitis arietans, Naja arabica, and Walterinnesia aegyptia were milked, lyophilized, diluted and centrifuged to separate the mucus from the venom. The clear supernatants were filtered and chromatographed on fast protein liquid chromatography (FPLC). We obtained the 16S rRNA gene sequences of the above species and performed phylogenetic analysis using the neighbor-joining method. The chromatograms of venoms from different snake species showed peculiar patterns based on the number and location of peaks. The dendrograms generated from similarity matrix based on the presence/absence of particular chromatographic peaks clearly differentiated Elapids from Viperids. Molecular cladistics using 16S rRNA gene sequences resulted in jumping clades while separating the members of these two families. These findings suggest that chromatographic profiles of snake venoms may provide a simple and reproducible chemical fingerprinting method for quick identification of snake species. However, the validation of this methodology requires further studies on large number of specimens from within and across species. PMID:25313278

  10. Enhancement of fluorescence detection in chromatographic methods by computer analysis of second order data. Progress report, August 1, 1990--October 1, 1993

    SciTech Connect

    Rutan, S.C.

    1993-12-31

    Two types of experiments were studied during the course of this project. The first was liquid chromatographic separation of polyaromatic hydrocarbons (PAHs) followed by detection with full-spectrum fluorescence spectroscopy using anintensified diode array detector. Methods such as generalized rank annihilation and adaptive Kalman filtering were developed and evaluated. The second was the use of a thin-layer chromatographic or planar electrophoretic separation of analytes (amino acids or enzymes). The analytes are then reacted with a reagent or enzyme substrate; the reaction is followed by fluorescence intensity vs time and migration distance, and kinetic analysis is used to quantify the component species.

  11. Pseudo-stationary separation materials for highly parallel separations.

    SciTech Connect

    Singh, Anup K.; Palmer, Christopher

    2005-05-01

    Goal of this study was to develop and characterize novel polymeric materials as pseudostationary phases in electrokinetic chromatography. Fundamental studies have characterized the chromatographic selectivity of the materials as a function of chemical structure and molecular conformation. The selectivities of the polymers has been studied extensively, resulting in a large body of fundamental knowledge regarding the performance and selectivity of polymeric pseudostationary phases. Two polymers have also been used for amino acid and peptide separations, and with laser induced fluorescence detection. The polymers performed well for the separation of derivatized amino acids, and provided some significant differences in selectivity relative to a commonly used micellar pseudostationary phase. The polymers did not perform well for peptide separations. The polymers were compatible with laser induced fluorescence detection, indicating that they should also be compatible with chip-based separations.

  12. Estimations of temperature deviations in chromatographic columns using isenthalpic plots. I. Theory for isocratic systems.

    PubMed

    Tarafder, Abhijit; Iraneta, Pamela; Guiochon, Georges; Kaczmarski, Krzysztof; Poe, Donald P

    2014-10-31

    We propose to use constant enthalpy or isenthalpic diagrams as a tool to estimate the extent of the temperature variations caused by the mobile phase pressure drop along a chromatographic column, e.g. of its cooling in supercritical fluid and its heating in ultra-performance liquid chromatography. Temperature strongly affects chromatographic phenomena. Any of its variations inside the column, whether intended or not, can lead to significant changes in separation performance. Although instruments use column ovens in order to keep constant the column temperature, operating conditions leading to a high pressure drop may cause significant variations of the column temperature, both in the axial and the radial directions, from the set value. Different ways of measuring these temperature variations are available but they are too inconvenient to be employed in many practical situations. In contrast, the thermodynamic plot-based method that we describe here can easily be used with only a ruler and a pencil. They should be helpful in developing methods or in analyzing results in analytical laboratories. Although the most effective application area for this approach should be SFC (supercritical fluid chromatography), it can be applied to any chromatographic conditions in which temperature variations take place along the column due to the pressure drop, e.g. in ultra-high pressure liquid chromatography (UHPLC). The method proposed here is applicable to isocractic conditions only. PMID:25267710

  13. Gas and liquid chromatographic analyses of nimodipine calcium antagonist in blood plasma and cerebrospinal fluid.

    PubMed

    Krol, G J; Noe, A J; Yeh, S C; Raemsch, K D

    1984-01-13

    Gas (GC) and liquid chromatographic (LC) assay procedures were developed for analysis of nimodipine (1,4-dihydropyridine calcium antagonist, BAY e 9736) in blood plasma at low nanogram concentration levels. To avoid decomposition during gas chromatography, nimodipine was oxidized to nimodipine pyridine (P) analogue before it was chromatographed on the OV-17 column and quantitated using an electron-capture detector. In contrast, the LC procedure involved chromatographic separation and quantitation of the underivatized nimodipine and of the endogenous P analogue using a 3-micron Spherisorb ODS column and UV detection. The same plasma extract and three alternative internal standards were used for both assays. Taking into consideration the fact that the GC assay result includes endogenous P analogue as well as nimodipine, good correlation between GC and LC assay data was obtained. Comparison of the results observed with the two procedures confirmed the accuracy of each procedure and provided an alternative when one of the assay results was subject to patient plasma constituent interference. The LC assay was also used for analysis of the demethylated metabolites of nimodipine. To detect sub-nanogram concentrations of nimodipine in cerebrospinal fluid a combined LC-GC procedure using an LC clean-up step and a GC quantitation step was also developed. The above GC and LC procedures were used to obtain preliminary pharmacokinetic data. PMID:6707134

  14. Acetic Acid Acts as a Volatile Signal To Stimulate Bacterial Biofilm Formation

    PubMed Central

    Chen, Yun; Gozzi, Kevin; Yan, Fang

    2015-01-01

    ABSTRACT Volatiles are small air-transmittable chemicals with diverse biological activities. In this study, we showed that volatiles produced by the bacterium Bacillus subtilis had a profound effect on biofilm formation of neighboring B. subtilis cells that grew in proximity but were physically separated. We further demonstrated that one such volatile, acetic acid, is particularly potent in stimulating biofilm formation. Multiple lines of genetic evidence based on B. subtilis mutants that are defective in either acetic acid production or transportation suggest that B. subtilis uses acetic acid as a metabolic signal to coordinate the timing of biofilm formation. Lastly, we investigated how B. subtilis cells sense and respond to acetic acid in regulating biofilm formation. We showed the possible involvement of three sets of genes (ywbHG, ysbAB, and yxaKC), all encoding putative holin-antiholin-like proteins, in cells responding to acetic acid and stimulating biofilm formation. All three sets of genes were induced by acetate. A mutant with a triple mutation of those genes showed a severe delay in biofilm formation, whereas a strain overexpressing ywbHG showed early and robust biofilm formation. Results of our studies suggest that B. subtilis and possibly other bacteria use acetic acid as a metabolic signal to regulate biofilm formation as well as a quorum-sensing-like airborne signal to coordinate the timing of biofilm formation by physically separated cells in the community. PMID:26060272

  15. Separation of Albumin, Ceruloplasmin, and Transferrin from Human Plasma.

    ERIC Educational Resources Information Center

    Barnes, Grady; Frieden, Earl

    1982-01-01

    Procedures are provided for separating the principal metalloproteins (albumin, ceruloplasmin, and transferrin) from plasma using column chromatographic techniques. The experiment can be completed in two separate three-hour laboratory periods during which column chromatography is illustrated and the effect of pH on charge and affinity of a protein…

  16. Analysis of a pyruvic acid acetal-containing polysaccharide by the reductive-cleavage method.

    PubMed

    Zeller, S G; Gray, G R

    1991-04-24

    The applicability of the reductive-cleavage method to the analysis of polysaccharides bearing pyruvic acid acetals has been demonstrated. Direct reductive cleavage of fully methylated gum xanthan yielded the expected products, including 1,5-anhydro-4,6-O-[(S)-1-methoxycarbonylethylidene]-2,3-di-O-methy l-D- mannitol. The latter product was not observed when reductive cleavage was performed subsequent to reduction of ester groups in the fully methylated polysaccharide and mild hydrolysis to remove pyruvic acid acetal substituents. Instead, the latter experiment yielded 1,5-anhydro-2,3-di-O-methyl-D-mannitol, establishing the presence in the polysaccharide of terminal (nonreducing) D-mannopyranosyl groups bearing 4,6-O-(1-carboxyethylidene) substituents. The products of reductive cleavage were characterized, where appropriate, by comparison of the gas chromatographic retention times and chemical ionization- and electron ionization-mass spectra of their acetates to those of authentic standards. Alternatively, the products of reductive cleavage could be characterized without resort to comparison with authentic standards by analysis of the 1H-n.m.r. spectra of their benzoates, which were obtained in pure form by high-performance liquid chromatography. By either method of product characterization, this two-step procedure of analysis reveals the presence of pyruvic-acetal residues in polysaccharides and establishes both the identity of the sugar residue to which they are attached and their positions of attachment. PMID:1769016

  17. Determination of medroxyprogesterone acetate in serum by HPLC with peroxyoxalate chemiluminescence detection using a fluorogenic reagent, 4-(N,N-dimethylaminosulphonyl)-7-hydrazino-2,1,3-benzoxadiazole.

    PubMed

    Uzu, S; Imai, K; Nakashima, K; Akiyama, S

    1992-01-01

    The high-performance liquid chromatographic determination of medroxyprogesterone acetate (MPA) with peroxyoxalate chemiluminescence (PO-CL) detection is described. The spiked serum containing MPA was extracted on Bond-Elut C18 columns and derivatized with 4-(N,N-dimethylaminosulphonyl)-7-hydrazino-2,1,3-benzoxadiazole (DBD-H). The hydrazone of MPA with DBD-H was confirmed to be a mono-DBD-derivative. The reaction mixture was separated by direct injection onto a C18 analytical column, and quantified by PO-CL detection. The linear range of the standard curve, in serum, was 15.6-96.6 ng ml-1 with a detection limit of 9 ng ml-1 using only 100 microliters of serum, while the detection limit of standard MPA derivatized with DBD-H was 8.7 fmol per injection. The relative standard deviation of the method was 7.4% at 19.3 ng and 1.7% at 77.3 ng ml-1. PMID:1298405

  18. Evaluation of coverage, retention patterns, and selectivity of seven liquid chromatographic methods for metabolomics.

    PubMed

    Wernisch, Stefanie; Pennathur, Subramaniam

    2016-09-01

    Liquid chromatography-mass spectrometry-based metabolomics studies require highly selective and efficient chromatographic techniques. Typically employed reversed-phase (RP) methods fail to target polar metabolites, but the introduction of hydrophilic interaction liquid chromatography (HILIC) is slow due to perceived issues of reproducibility and ruggedness and a limited understanding of the complex retention mechanisms. In this study, we present a comparison of the chromatographic performance of a traditional RP-C18 column with zwitterionic, amide-, alkyl diol-, and aminoalkyl-based HILIC and mixed-mode columns. Our metabolite library represents one of the largest analyte sets available and consists of 764 authentic metabolite standards, including amino acids, nucleotides, sugars, and other metabolites, representing all major biological pathways and commonly observed exogenous metabolites (drugs). The coverage, retention patterns, and selectivity of the individual methods are highly diverse even between conceptually related HILIC methods. Furthermore, we show that HILIC sorbents having highly orthogonal selectivity and specificity enhance the coverage of major metabolite groups in (semi-) targeted applications compared to RP. Finally, we discuss issues encountered in the analysis of biological samples based on the results obtained with human plasma extracts. Our results demonstrate that fast and highly reproducible separations on zwitterionic columns are feasible, but knowledge of analyte properties is essential to avoid chromatographic bias and exclusion of key analytes in metabolomics studies. Graphical Abstract The chromatographic parameters of 764 authentic metabolite standards provide the basis for a comparison of coverage, selectivity and orthogonality of 7 reversed-phase (RP), mixed-mode (MM) and hydrophilic interaction liquid chromatography (HILIC) methods. PMID:27370688

  19. Rapid chromatographic method to decipher distinct alterations in lipid classes in NAFLD/NASH

    PubMed Central

    Laggai, Stephan; Simon, Yvette; Ranssweiler, Theo; Kiemer, Alexandra K; Kessler, Sonja M

    2013-01-01

    AIM: To establish a simple method to quantify lipid classes in liver diseases and to decipher the lipid profile in p62/IMP2-2/IGF2BP2-2 transgenic mice. METHODS: Liver-specific overexpression of the insulin-like growth factor 2 mRNA binding protein p62/IMP2-2/IGF2BP2-2 was used as a model for steatosis. Steatohepatitis was induced by feeding a methionine-choline deficient diet. Steatosis was assessed histologically. For thin layer chromatographic analysis, lipids were extracted from freeze-dried tissues by hexane/2-propanol, dried, redissolved, and chromatographically separated by a two-solvent system. Dilution series of lipid standards were chromatographed, detected, and quantified. The detection was performed by either 2’,7’-dichlorofluoresceine or a sulfuric acid/ethanol mixture. RESULTS: Histological analyses confirmed steatosis and steatohepatitis development. The extraction, chromatographic, and detection method showed high inter-assay reproducibility and allowed quantification of the different lipid classes. The analyses confirmed an increase of triglycerides and phosphatidylethanolamine and a decrease in phosphatidylcholine in the methionine-choline deficient diet. The method was used for the first time to asses the lipid classes induced in the p62-overexpressing mouse model and showed a significant increase in all detected lipid species with a prominent increase of triglycerides by 2-fold. Interestingly, the ratio of phosphatidylcholine to phosphatidylethanolamine was decreased, as previously suggested as a marker in the progression from steatosis to steatohepatitis. CONCLUSION: The thin layer chromatography analysis allows a reliable quantification of lipid classes and provides detailed insight into the lipogenic effect of p62. PMID:24179615

  20. Liquid chromatographic determination of nicarbazin in feeds.

    PubMed

    Krabel, B J; Dickson, D A; Zimmermann, A G; Coleman, M R

    2000-01-01

    A new liquid chromatographic method has been developed for determination of nicarbazin in feeds. Approximately 40 g feed is extracted with 200 mL acetonitrile-water (80 + 20, v/v). An aliquot of the extract is filtered and assayed using a reversed-phase isocratic method that measures the 4,4'-dinitrocarbanilide moiety of nicarbazin at a wavelength of 340 nm. For medicated feeds, the method uses a standard linear range of 5 to 100 microg/mL. For lower levels, a linear range of 50 to 150 ng/mL can be used. The method has a limit of detection of 250 ng/g and a limit of quantitation of 500 ng/g in a 40 g feed sample. Recovery was 99.1%, with a range of 95.2 to 101.8%. In the typical U.S. dosing range of 27 to 113.5 g/ton, the precision of the method based on one analyst, one day, and 2 weighings ranged from 2.8% (113.5 g/ton) to 4.7% (27 g/ton). PMID:11048841

  1. Simple gas chromatographic method for furfural analysis.

    PubMed

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-01

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSD<8%), showed good recoveries (77-107%) and good limits of detection (GC-FID: 1.37 microgL(-1) for 2-F, 8.96 microgL(-1) for 5-MF, 6.52 microgL(-1) for 5-HMF; GC-TOF-MS: 0.3, 1.2 and 0.9 ngmL(-1) for 2-F, 5-MF and 5-HMF, respectively). It was applied to different commercial food matrices: honey, white, demerara, brown and yellow table sugars, and white and red balsamic vinegars. This one-step, sensitive and direct method for the analysis of furfurals will contribute to characterise and quantify their presence in the human diet. PMID:18976770

  2. Quality improvements of cell membrane chromatographic column.

    PubMed

    Ding, Xuan; Chen, Xiaofei; Cao, Yan; Jia, Dan; Wang, Dongyao; Zhu, Zhenyu; Zhang, Juping; Hong, Zhanying; Chai, Yifeng

    2014-09-12

    Cell Membrane Chromatography (CMC) is a biological affinity chromatographic method using a silica stationary phase covered with specific cell membrane. However, its short life span and poor quality control was highlighted in a lot of research articles. In this study, special attention has been paid to the disruption, cell load and packing procedure in order to improve the quality of the CMC columns. Hereto, two newly established CMC models, HSC-T6/CMC and SMMC-7721/CMC have been developed and used in this research project. The optimization of the abovementioned parameters resulted in a better reproducibility of the retention time of the compound GFT (RSD<10%) and improved significantly the quality of the CMC columns. 3.5×10(7)cells were the optimal cell load for the preparation of the CMC columns, the disruption condition was optimized to 5 cycles (400W and 20s interval per cycle) by an ultrasonic processor reducing the total time of cell disruption to 1.5min and the packing flow rate was optimized by applying a linear gradient program. Additionally, 4% paraformaldehyde (PFA) was employed to improve the column quality and prolong the column life span. The results showed that the retention time was longer with PFA treated columns than the ones obtained with the control groups. PMID:25115453

  3. Liquid chromatographic assay for dicloxacillin in plasma.

    PubMed

    Alderete, Oscar; González-Esquivel, Dinora F; Del Rivero, L Misael; Castro Torres, Nelly

    2004-06-15

    A simple high-performance liquid chromatographic method for the determination of dicloxacillin in plasma has been developed. The method only requires 0.5 ml of plasma, phosphate buffer solution (pH = 4.7), acidification with 0.5N hydrochloride acid and liquid extraction with dichloromethane. Posterior evaporation of organic under nitrogen steam and redissolution in mobile phase is carried out. The analysis was performed on a Spherisorb C18 (5 microm) column, using methanol -0.05 M phosphate buffer, pH = 4.7 (75:25; v/v) as mobile phase, with ultraviolet detection at 220 nm. Results showed that the assay is sensitive: 0.5 microg/ml. The response is linear in the range of 0.5 - 10 microg/ml. Maximum inter-day coefficient of variation was 12.4%. Mean extraction recovery obtained was 96.95%. Stability studies showed that the loss was not higher than 10%, samples are stable at room temperature for 6 h, at -20 Celsius for 2 months, processed samples were stable at least for 24 h and also after two freeze-thaw cycles. The method has been used to perform pharmacokinetic and bioequivalence studies in humans. PMID:15135112

  4. URANIUM SEPARATION PROCESS

    DOEpatents

    Hyde, E.K.; Katzin, L.I.; Wolf, M.J.

    1959-07-14

    The separation of uranium from a mixture of uranium and thorium by organic solvent extraction from an aqueous solution is described. The uranium is separrted from an aqueous mixture of uranium and thorium nitrates 3 N in nitric acid and containing salting out agents such as ammonium nitrate, so as to bring ihe total nitrate ion concentration to a maximum of about 8 N by contacting the mixture with an immiscible aliphatic oxygen containing organic solvent such as diethyl carbinol, hexone, n-amyl acetate and the like. The uranium values may be recovered from the organic phase by back extraction with water.

  5. PLUTONIUM SEPARATION METHOD

    DOEpatents

    Beaufait, L.J. Jr.; Stevenson, F.R.; Rollefson, G.K.

    1958-11-18

    The recovery of plutonium ions from neutron irradiated uranium can be accomplished by bufferlng an aqueous solutlon of the irradiated materials containing tetravalent plutonium to a pH of 4 to 7, adding sufficient acetate to the solution to complex the uranyl present, adding ferric nitrate to form a colloid of ferric hydroxide, plutonlum, and associated fission products, removing and dissolving the colloid in aqueous nitric acid, oxldizlng the plutonium to the hexavalent state by adding permanganate or dichromate, treating the resultant solution with ferric nitrate to form a colloid of ferric hydroxide and associated fission products, and separating the colloid from the plutonlum left in solution.

  6. Organic contaminant separator

    DOEpatents

    Del Mar, Peter; Hemberger, Barbara J.

    1991-01-01

    A process of sample preparation prior to analysis for the concentration of an organic contaminant in an aqueous medium by (a) passing an initial aqueous medium including a minor amount of the organic contaminant through a polyolefin tube having an internal diameter of from about 0.01 to about 2.0 millimeters and being of sufficient length to permit the organic contaminant to adhere to the tube, (b) passing a solvent through the tube, said solvent capable of separating the adhered organic contaminant from the tube. Further, a chromatographic apparatus for sample preparation prior to analysis for the concentration of an organic contaminant in an aqueous medium, said apparatus including a polyolefin tube having an internal diameter of from about 0.01 to about 2.0 millimeters and being of sufficient length to permit an organic contaminant contained within an aqueous medium passed therethrough to adhere to the tube is disclosed.

  7. High-performance liquid chromatographic characterization of some medical plant extracts used in cosmetic formulas.

    PubMed

    Schulz, H; Albroscheit, G

    1988-06-17

    Rapid and reliable methods are presented for the characterization of biologically active and/or characteristic constituents in aqueous extracts of Hamamelis virginiana, Matricaria chamomilla, Achillea millefolium, Thymus vulgaris, Althaea officinalis and Cinchonia spp. Prior to high-performance liquid chromatographic (HPLC) separation a clean-up step was performed using a solid-phase extraction system. The purified extracts were analysed by HPLC coupled with a diode-array detector and a fluorescence detector. In some instances, previously unreported components of the aqueous plant extracts were found. PMID:3417826

  8. Computerized gas chromatographic-mass spectrometric analysis of polycyclic aromatic hydrocarbons in environmental samples.

    PubMed

    Lao, R C; Thomas, R S; Monkman, J L

    1975-10-29

    Substantial progress has been made in the last few years in the development of a rapid method for determining polycyclic aromatic hydrocarbons (PAH) in environmental samples. The three-step method consists of (i) a preliminary separation of PAH by solvent and/or column chromatography, (ii) identification by a combination of gas chromatography with quadrupole mass spectrometry and computer, and (iii) measurement by computerized gas chromatography using internal standards. Samples of industrial effluents, coke oven emissions, coal tar and airborne particulates have been investigated. The efficiencies of different gas chromatographic columns were evaluated during these investigations. PMID:1184696

  9. Silica sol assisted chromatographic NMR spectroscopy for resolution of trans- and cis-isomers.

    PubMed

    Yang, Ying; Wu, Rui; Huang, Shaohua; Bai, Zhengwu

    2016-04-01

    Chromatographic NMR spectroscopy can separate the mixtures of species with significantly different molecular size, but generally fails for isomeric species. Herein, we reported the resolution of trans- and cis-isomers and their structural analogue, which are different in molecular shapes, but similar in mass, were greatly enhanced in the presence of silica sol. The mixtures of maleic acid, fumaric acid and succinic acid, and the mixtures of trans- and cis-1,2-cyclohexanedicarboxylic acids, were distinguished by virtue of their different degrees of interaction with silica sol. Moreover, we found mixed solvents could improve the spectral resolution of DOSY spectra of mixtures. PMID:26942864

  10. Silica sol assisted chromatographic NMR spectroscopy for resolution of trans- and cis-isomers

    NASA Astrophysics Data System (ADS)

    Yang, Ying; Wu, Rui; Huang, Shaohua; Bai, Zhengwu

    2016-04-01

    Chromatographic NMR spectroscopy can separate the mixtures of species with significantly different molecular size, but generally fails for isomeric species. Herein, we reported the resolution of trans- and cis-isomers and their structural analogue, which are different in molecular shapes, but similar in mass, were greatly enhanced in the presence of silica sol. The mixtures of maleic acid, fumaric acid and succinic acid, and the mixtures of trans- and cis-1,2-cyclohexanedicarboxylic acids, were distinguished by virtue of their different degrees of interaction with silica sol. Moreover, we found mixed solvents could improve the spectral resolution of DOSY spectra of mixtures.

  11. Chromatographic and fluorescence spectroscopic studies of individual 7,12-dimethylbenz(a)anthracene--deoxyribonucleoside adducts

    SciTech Connect

    Moschel, R.C.; Pigott, M.A.; Costantino, N.; Dipple, A.

    1983-09-01

    Compared with standard Sephadex LH-20 column chromatography, a newly developed high pressure liquid chromatographic separation of hydrocarbon deoxyribonucleoside adducts derived from the DNA of mouse embryo cell cultures exposed to 7,12-dimethylbenz(a)anthracene (DMBA) provides markedly superior resolution. Once resolved, the fluorescence spectroscopic properties of the three major DMBA--DNA adducts indicate that the fluorescence exhibited by adducts derived from a bay region syn dihydrodiol epoxide of DMBA differs subtly from that exhibited by adducts derived from the isomeric anti dihydrodiol epoxide.

  12. Reversed-phase high-performance liquid chromatographic method for the assay of oxytetracycline.

    PubMed

    Barnes, W N; Ray, A; Bates, L J

    1985-10-25

    The British Pharmacopoeia monograph for oxytetracycline calcium describes an high-performance liquid chromatographic (HPLC) assay which requires packing of the column by the analyst. Presented in this report is an HPLC method for the assay of oxytetracycline which employs a commercially available reversed-phase column and a solvent system which gives improved separation of the antibiotic from common impurities. Results obtained using this method for both bulk and dosage forms of oxytetracycline are in accord with the results of the microbiological assays. PMID:4086631

  13. Fully automated high-performance liquid chromatographic assay for the analysis of free catecholamines in urine.

    PubMed

    Said, R; Robinet, D; Barbier, C; Sartre, J; Huguet, C

    1990-08-24

    A totally automated and reliable high-performance liquid chromatographic method is described for the routine determination of free catecholamines (norepinephrine, epinephrine and dopamine) in urine. The catecholamines were isolated from urine samples using small alumina columns. A standard automated method for pH adjustment of urine before the extraction step has been developed. The extraction was performed on an ASPEC (Automatic Sample Preparation with Extraction Columns, Gilson). The eluate was collected in a separate tube and then automatically injected into the chromatographic column. The catecholamines were separated by reversed-phase ion-pair liquid chromatography and quantified by fluorescence detection. No manual intervention was required during the extraction and separation procedure. One sample may be run every 15 min, ca. 96 samples in 24 h. Analytical recoveries for all three catecholamines are 63-87%, and the detection limits are 0.01, 0.01, and 0.03 microM for norepinephrine, epinephrine and dopamine, respectively, which is highly satisfactory for urine. Day-to-day coefficients of variation were less than 10%. PMID:2277100

  14. Use of liquid chromatography in the synthesis of isoluminol-labeled medroxyprogesterone acetate and zeranol.

    PubMed

    Koehler, H; Larocque, L; Sved, S

    1989-05-19

    A high-performance liquid chromatographic (HPLC) method for monitoring the syntheses of two isoluminol-labelled drugs, medroxyprogesterone acetate (MPA) and zeranol, has been developed. MPA and the ketone derivative of zeranol, zearalanone, were conjugated to N-(4-aminobutyl)-N-ethylisoluminol through the carboxymethyloxime derivative of the drug by using the N-succinimide ester as an intermediary. Reaction mixtures were sampled periodically and chromatographed directly by HPLC on a silica gel column, by using isocratic elution with mixtures of hexane-ethanol-acetic acid in several different proportions. The degree of reaction completion was determined by comparison of the peak area of the initial reactant to that present at sampling time. MPA oxime production was found to be complete after 15 min; 97.0% of the oxime was converted to succinimide ester in 24 h; 99.0% of the available ester reacted within 2.5 h to form the final labelled product. Zearalanone oxime production was found to be complete after 2 h; 93.3% of the oxime was converted to the activated ester within 24 h; 89.6% of available ester had reacted in 30 min to form the final labelled product. The chromatography can be performed in real time, permitting modification in the conditions of the reaction while in progress. PMID:2768375

  15. PATTERN RECOGNITION STUDIES OF COMPLEX CHROMATOGRAPHIC DATA SETS

    EPA Science Inventory

    Chromatographic fingerprinting of complex biological samples is an active research area with a large and growing literature. Multivariate statistical and pattern recognition techniques can be effective methods for the analysis of such complex data. However, the classification of ...

  16. CHROMATOGRAPHIC AND MASS SPECTRAL STUDIES OF PERFLUOROOCTANESULFONATE AND THREE PERFLUOROOCTANESULFONAMIDES

    EPA Science Inventory

    The chromatographic and mass spectral characteristics of perfluorooctanesulfonate (PFOS) and three nitrogen-substituted perfluorooctanesulfonamides have been obtained. A methyl/phenol mixed phase fused silica capillary column was used for GC analysis, while a C18 reversed phase ...

  17. Understanding Palladium Acetate from a User Perspective.

    PubMed

    Carole, William A; Colacot, Thomas J

    2016-06-01

    The behavior of palladium acetate is reviewed with respect to its synthesis, characterization, structure (in both solution and solid state), and activation pathways. In addition, comparisons of catalytic activities between pure palladium acetate and two common byproducts, Pd3 (OAc)5 (NO2 ) and polymeric [Pd(OAc)2 ]n , typically present in commercially available material are reviewed. Hence, this minireview serves as a concise guide for the users of palladium acetate from both academia and industry. PMID:27125630

  18. 21 CFR 184.1005 - Acetic acid.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Acetic acid. 184.1005 Section 184.1005 Food and... Substances Affirmed as GRAS § 184.1005 Acetic acid. (a) Acetic acid (C2H4O2, CAS Reg. No. 64-19-7) is known as ethanoic acid. It occurs naturally in plant and animal tissues. It is produced by fermentation...

  19. 21 CFR 184.1005 - Acetic acid.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Acetic acid. 184.1005 Section 184.1005 Food and... Substances Affirmed as GRAS § 184.1005 Acetic acid. (a) Acetic acid (C2H4O2, CAS Reg. No. 64-19-7) is known as ethanoic acid. It occurs naturally in plant and animal tissues. It is produced by fermentation...

  20. 21 CFR 184.1721 - Sodium acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... sodium sulfate and sodium bicarbonate. (b) The ingredient meets the specifications of the Food Chemicals... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sodium acetate. 184.1721 Section 184.1721 Food and... Substances Affirmed as GRAS § 184.1721 Sodium acetate. (a) Sodium acetate (C2H3O2Na, CAS Reg. No. 127-09-3...

  1. 21 CFR 184.1721 - Sodium acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... sodium sulfate and sodium bicarbonate. (b) The ingredient meets the specifications of the Food Chemicals... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Sodium acetate. 184.1721 Section 184.1721 Food and... Substances Affirmed as GRAS § 184.1721 Sodium acetate. (a) Sodium acetate (C2H3O2Na, CAS Reg. No. 127-09-3...

  2. 21 CFR 184.1721 - Sodium acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... sodium sulfate and sodium bicarbonate. (b) The ingredient meets the specifications of the Food Chemicals... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Sodium acetate. 184.1721 Section 184.1721 Food and... Substances Affirmed as GRAS § 184.1721 Sodium acetate. (a) Sodium acetate (C2H3O2Na, CAS Reg. No. 127-09-3...

  3. A novel ion-pairing chromatographic method for the simultaneous determination of both nicarbazin components in feed additives: chemometric tools for improving the optimization and validation.

    PubMed

    De Zan, María M; Teglia, Carla M; Robles, Juan C; Goicoechea, Héctor C

    2011-07-15

    The development, optimization and validation of an ion-pairing high performance liquid chromatography method for the simultaneous determination of both nicarbazin (NIC) components: 4,4'-dinitrocarbanilide (DNC) and 2-hydroxy-4,6-dimethylpyrimidine (HDP) in bulk materials and feed additives are described. An experimental design was used for the optimization of the chromatographic system. Four variables, including mobile phase composition and oven temperature, were analyzed through a central composite design exploring their contribution to analyte separation. Five responses: peak resolutions, HDP capacity factor, HDP tailing and analysis time, were modelled by using the response surface methodology and were optimized simultaneously by implementing the desirability function. The optimum conditions resulted in a mobile phase consisting of 10.0 mmol L(-1) of 1-heptanesulfonate, 20.0 mmol L(-1) of sodium acetate, pH=3.30 buffer and acetonitrile in a gradient system at a flow rate of 1.00 mL min(-1). Column was an INERSTIL ODS-3 (4.6 mm×150 mm, 5 μm particle size) at 40.0°C. Detection was performed at 300 nm by a diode array detector. The validation results of the method indicated a high selectivity and good precision characteristics, with RSD less than 1.0% for both components, both in intra and inter-assay precision studies. Linearity was proved for a range of 32.0-50.0 μg mL(-1) of NIC in sample solution. The recovery, studied at three different fortification levels, varied from 98.0 to 101.4 for HDP and from 99.1 to 100.2 for DNC. The applicability of the method was demonstrated by determining DNC and HDP content in raw materials and commercial formulations used for coccidiosis prevention. Assays results on real samples showed that considerable differences in molecular ratio DNC:HDP exist among them. PMID:21645683

  4. Development of a quantitative high-performance thin-layer chromatographic method for sucralose in sewage effluent, surface water, and drinking water.

    PubMed

    Morlock, Gertrud E; Schuele, Leonard; Grashorn, Sebastian

    2011-05-13

    Sucralose, a persistent chlorinated substance used as sweetener, can already be found in waste water, and various countries focused on the release of sucralose into the aquatic environment. A quantitative high-performance thin-layer chromatography (HPTLC) method, which is orthogonal to existing methods, was developed to analyze sucralose in water. After sample preparation, separation of up to 17 samples was performed in parallel on a HPTLC plate silica gel 60 F(254) with a mixture of isopropyl acetate, methanol and water (15:3:1, v/v/v) within 15 min. Due to the weak native UV absorption of sucralose (≤200 nm), various post-chromatographic derivatization reactions were compared to selectively detect sucralose in effluent and surface water matrices. Thereby p-aminobenzoic acid reagent was discovered as a new derivatization reagent for sucralose. Compared to the latter and to β-naphthol, derivatization with aniline diphenylamine o-phosphoric acid reagent was slightly preferred and densitometry was performed by absorbance measurement at 400 nm. The limit of quantification (LOQ) of sucralose in drinking and surface water was calculated to be 100 ng/L for a given recovery rate of 80% and the extraction of a 0.5 L water sample. The sucralose content determined in four water samples obtained during an interlaboratory trial in 2008 was in good agreement to the mean laboratory values of that trial. According to the t-test, which compares the results with the target value, the means obtained by HPTLC were not significantly different from the respective means of six laboratories, analyzed by HPLC-MS/MS or HPLC-TOF-MS with the use of mostly isotopically labeled standards. The good accuracy and high sample throughput capacity proved HPTLC as a well suited method regarding quantification of sucralose in various aqueous matrices. PMID:21185029

  5. Two high performance liquid chromatographic methods for the determination of alpha-tocopherol in serum compared to isotope dilution-gas chromatography-mass spectrometry.

    PubMed

    Kock, R; Seitz, S; Delvoux, B; Greiling, H

    1997-05-01

    Two high performance liquid chromatographic methods (HPLC) with isocratic reversed-phase separation are presented for the determination of alpha-tocopherol (vitamin E) in serum. In the first method alpha-tocopherol acetate is used as internal standard, detection of absorbance is performed at 284 nm. In the second method tocol is used as internal standard, detection of fluorescence is performed with an excitation wavelength of 292 nm and emission wavelength of 325 nm. Both methods require a liquid-liquid extraction as sample preparation. The results of both HPLC methods have been tested by method comparison for n = 25 serum samples versus an isotope dilution-gas chromatography-mass spectrometry (ID-GC-MS) method using alpha-tocopherol-d6 as internal standard. The imprecision within-run was lower than 2.5% for the UV method and lower than 1% for the fluorescence method for both standards and serum pools. The between-run imprecision, obtained for serum pools, was below 5% for the UV method and not higher than 1.5% for the fluorescence method and not higher 1.8% for the ID-GC-MS. Recovery experiments performed by spiking pool sera with alpha-tocopherol showed recoveries between 98.5% and 100.6% for all methods studied. The result of the method comparison was a coefficient of correlation of r = 0.998 for the HPLC method with fluorescence detection to the ID-GC-MS reference method and a coefficient of correlation of r = 0.981 for the HPLC method with UV detection to the ID-GC-MS reference method. Both methods presented are useful for the analysis of alpha-tocopherol in patient samples. If detection of fluorescence is used, imprecision and inaccuracy of the HPLC method are comparable to the ID-GC-MS chosen as reference method. PMID:9189742

  6. Non-targeted chromatographic analyses of cuticular wax flavonoids from Physalis alkekengi L.

    PubMed

    Kranjc, Eva; Albreht, Alen; Vovk, Irena; Makuc, Damjan; Plavec, Janez

    2016-03-11

    Since Chinese lantern (Physalis alkekengi L.) represents a rich source of various bioactive secondary metabolites, there is an urge for its detailed characterization. Non-polar flavonoid aglycones represent one of the few bioactive species found in plant's cuticular waxes. The separation of flavonoids is already extensively covered in the literature, but methods dedicated to separation and identification of methylated flavonoids are rather scarce. In the present study a non-targeted approach for the separation, isolation and identification of methylated flavonoids present in P. alkekengi L. var. franchetii cuticular waxes was established. A rapid and simple separation on HPTLC silica gel was developed for preliminary screening of flavonoids. Fast HPLC-UV-MS(n) and HPLC-UV methods using a C6-Phenyl and a C18 stationary phase were also developed, respectively. In both cases, the right combination of temperature and tetrahydrofuran, as a mobile phase modifier, were shown to be crucial for a baseline separation of all studied compounds. By employing a semi-preparative analog of the C18 column, a simultaneous isolation of pure unknown analytes was achieved. Using these developed methods in combination with NMR, four 3-O-methylated flavonols were detected and identified in P. alkekengi L. var. franchetii cuticular waxes: myricetin 3,7,3'-trimethyl ether, quercetin 3,7-dimethyl ether, myricetin 3,7,3',5'-tetramethyl ether and quercetin 3,7,3'-trimethyl ether. Moreover, the simple and fast isocratic HPLC-UV-MS(n) method (under 8min) should prove useful in quality control of P. alkekengi L. var. franchetii by enabling chromatographic fingerprinting of external methylated flavonols. Finally, a rationale for the mechanism of separation of these metabolites by HPLC is also given, which establishes a foundation for future development of chromatographic methods for methylated flavonols and related compounds. PMID:26875116

  7. Method for liquid chromatographic extraction of strontium from acid solutions

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  8. Analysis of all-rac-alpha-tocopheryl acetate and retinyl palmitate in medical foods using a zero control reference material (ZRM) as a method development tool.

    PubMed

    Chase, G W; Eitenmiller, R R; Long, A R

    1999-01-01

    A liquid chromatographic method is described for analysis of all- rac-alpha-tocopheryl acetate and retinyl palmitate in medical food. The vitamins are extracted in isopropyl alcohol and hexane-ethyl acetate without saponification and quantitated by normal-phase chromatography with fluorescence detection. All rac-alpha-tocopheryl acetate and retinyl palmitate are chromatographed isocratically with a mobile phase of 0.5% (v/v) and 0.125% (v/v) isopropyl alcohol in hexane, respectively. Recovery studies performed on a medical food zero control reference material (ZRM) fortified with the analytes averaged 99.7% (n = 25) for retinyl palmitate and 101% (n = 25) for all- rac-alpha-tocopheryl acetate. Coefficients of variation were 0.87-2.63% for retinyl palmitate and 1.42-3.20% for all-rac-alpha-tocopheryl acetate. The method provides a rapid, specific, and easily controlled assay for analysis of vitamin A and vitamin E in medical foods. Use of chlorinated solvents is avoided. PMID:10232898

  9. Positron scattering from vinyl acetate

    NASA Astrophysics Data System (ADS)

    Chiari, L.; Zecca, A.; Blanco, F.; García, G.; Brunger, M. J.

    2014-09-01

    Using a Beer-Lambert attenuation approach, we report measured total cross sections (TCSs) for positron scattering from vinyl acetate (C4H6O2) in the incident positron energy range 0.15-50 eV. In addition, we also report an independent atom model with screening corrected additivity rule computation results for the TCSs, differential and integral elastic cross sections, the positronium formation cross section and inelastic integral cross sections. The energy range of these calculations is 1-1000 eV. While there is a reasonable qualitative correspondence between measurement and calculation for the TCSs, in terms of the energy dependence of those cross sections, the theory was found to be a factor of ˜2 larger in magnitude at the lower energies, even after the measured data were corrected for the forward angle scattering effect.

  10. Extractive fermentation of acetic acid

    SciTech Connect

    Busche, R.M.

    1991-12-31

    In this technoeconomic evaluation of the manufacture of acetic acid by fermentation, the use of the bacterium: Acetobacter suboxydans from the old vinegar process was compared with expected performance of the newer Clostridium thermoaceticum bacterium. Both systems were projected to operate as immobilized cells in a continuous, fluidized bed bioreactor, using solvent extraction to recover the product. Acetobacter metabolizes ethanol aerobically to produce acid at 100 g/L in a low pH medium. This ensures that the product is in the form of a concentrated extractable free acid, rather than as an unextractable salt. Unfortunately, yields from glucose by way of the ethanol fermentation are poor, but near the biological limits of the organisms involved. Conversely, C. thermoaceticum is a thermophilic anaerobe that operates at high fermentation rates on glucose at neutral pH to produce acetate salts directly in substantially quantitative yields. However, it is severely inhibited by product, which restricts concentration to a dilute 20 g/L. An improved Acetobacter system operating with recycled cells at 50 g/L appears capable of producing acid at $0.38/lb, as compared with a $0.29/lb price for synthetic acid. However, this system has only a limited margin for process improvement. The present Clostridium system cannot compete, since the required selling price would be $0.42/lb. However, if the organism could be adapted to tolerate higher product concentrations at acid pH, selling price could be reduced to $0.22/lb, or about 80% of the price of synthetic acid.

  11. Acute alcohol intoxication decreases glucose metabolism but increases acetate uptake in the human brain.

    PubMed

    Volkow, Nora D; Kim, Sung Won; Wang, Gene-Jack; Alexoff, David; Logan, Jean; Muench, Lisa; Shea, Colleen; Telang, Frank; Fowler, Joanna S; Wong, Christopher; Benveniste, Helene; Tomasi, Dardo

    2013-01-01

    Alcohol intoxication results in marked reductions in brain glucose metabolism, which we hypothesized reflect not just its GABAergic enhancing effects but also the metabolism of acetate as an alternative brain energy source. To test this hypothesis we separately assessed the effects of alcohol intoxication on brain glucose and acetate metabolism using Positron Emission Tomography (PET). We found that alcohol intoxication significantly decreased whole brain glucose metabolism (measured with FDG) with the largest decrements in cerebellum and occipital cortex and the smallest in the thalamus. In contrast, alcohol intoxication caused a significant increase in [1-(11)C]acetate brain uptake (measured as standard uptake value, SUV), with the largest increases occurring in the cerebellum and the smallest in the thalamus. In heavy alcohol drinkers [1-(11)C]acetate brain uptake during alcohol challenge tended to be higher than in occasional drinkers (p<0.06) and the increases in [1-(11)C]acetate uptake in cerebellum with alcohol were positively associated with the reported amount of alcohol consumed (r=0.66, p<0.01). Our findings corroborate a reduction of brain glucose metabolism during intoxication and document an increase in brain acetate uptake. The opposite changes observed between regional brain metabolic decrements and regional increases in [1-(11)C]acetate uptake support the hypothesis that during alcohol intoxication the brain may rely on acetate as an alternative brain energy source and provides preliminary evidence that heavy alcohol exposures may facilitate the use of acetate as an energy substrate. These findings raise the question of the potential therapeutic benefits that increasing plasma acetate concentration (i.e. ketogenic diets) may have in alcoholics undergoing alcohol detoxification. PMID:22947541

  12. Fundamental studies of chalcogenide nanocrystals, carbonaceous nanoparticles, and chromatographic materials

    NASA Astrophysics Data System (ADS)

    Baker, Jared Scott

    2011-12-01

    The development of novel nanomaterials and the understanding of their fundamental physical and chemical properties represent an exciting area of research. These materials are continuously being sought for ever-increasing applications; finding their way into uses that influence mankind on a daily basis. Combining elements from traditional nanoparticle characterization with electrophoretic-based techniques, this dissertation presents the analysis of carbon nanoparticles (CNPs) generated from a novel source (candle soot) as well as a unique perspective on the reactivity and degradation process of magic-sized cadmium chalcogenide nanocrystals. One potential application of CNPs is their use as an alternative fluorophore in a separation-based sensor system. Laser-induced-fluorescence (LIF) is a commonly used manner of detection in this type of platform, but is limited in many cases by problems associated with the fluorophore. Carbon-based nanoparticles have the potential to improve upon traditional fluorophores in applications that make use of LIF as the detection scheme. CNPs were extracted from the carbonaceous material produced by the incomplete combustion of a candle. The soot was submitted to an oxidizing treatment and extraction/filtration procedures rendering watersoluble luminescent species. Electron microscopy was used to identify globular, amorphous structures in the nanometer size-range. An aqueous suspension of CNPs demonstrated excellent stability in terms of its electronic properties, showing little change in absorption and emission spectra upon storage under ambient conditions over a two-year period. Capitalizing on the strengths of capillary electrophoresis (CE) as a characterization technique, we have analyzed the negatively-charged CNPs in terms of charge and size by studying the influence of variable CE conditions on the resulting separation. Separations at different pH revealed a highly complex mixture of CNPs, containing species with large

  13. Ultracapacitor separator

    DOEpatents

    Wei, Chang; Jerabek, Elihu Calvin; LeBlanc, Jr., Oliver Harris

    2001-03-06

    An ultracapacitor includes two solid, nonporous current collectors, two porous electrodes separating the collectors, a porous separator between the electrodes and an electrolyte occupying the pores in the electrodes and separator. The electrolyte is a polar aprotic organic solvent and a salt. The porous separator comprises a wet laid cellulosic material.

  14. PROCESS FOR SEPARATION OF HEAVY METALS

    DOEpatents

    Duffield, R.B.

    1958-04-29

    A method is described for separating plutonium from aqueous acidic solutions of neutron-irradiated uranium and the impurities associated therewith. The separation is effected by adding, to the solution containing hexavalent uranium and plutonium, acetate ions and the ions of an alkali metal and those of a divalent metal and thus forming a complex plutonium acetate salt which is carried by the corresponding complex of uranium, such as sodium magnesium uranyl acetate. The plutonium may be separated from the precipitated salt by taking the same back into solution, reducing the plutonium to a lower valent state on reprecipitating the sodium magnesium uranyl salt, removing the latter, and then carrying the plutonium from ihe solution by means of lanthanum fluoride.

  15. 21 CFR 556.380 - Melengestrol acetate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 6 2012-04-01 2012-04-01 false Melengestrol acetate. 556.380 Section 556.380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Tolerances for Residues of New Animal Drugs § 556.380 Melengestrol acetate. A tolerance of 25 parts...

  16. 21 CFR 556.380 - Melengestrol acetate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 6 2014-04-01 2014-04-01 false Melengestrol acetate. 556.380 Section 556.380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Tolerances for Residues of New Animal Drugs § 556.380 Melengestrol acetate. A tolerance of 25 parts...

  17. 21 CFR 556.380 - Melengestrol acetate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 6 2013-04-01 2013-04-01 false Melengestrol acetate. 556.380 Section 556.380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Tolerances for Residues of New Animal Drugs § 556.380 Melengestrol acetate. A tolerance of 25 parts...

  18. 21 CFR 556.380 - Melengestrol acetate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 6 2011-04-01 2011-04-01 false Melengestrol acetate. 556.380 Section 556.380 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL... Tolerances for Residues of New Animal Drugs § 556.380 Melengestrol acetate. A tolerance of 25 parts...

  19. Manufacturing Ethyl Acetate From Fermentation Ethanol

    NASA Technical Reports Server (NTRS)

    Rohatgi, Naresh K.; Ingham, John D.

    1991-01-01

    Conceptual process uses dilute product of fermentation instead of concentrated ethanol. Low-concentration ethanol, extracted by vacuum from fermentation tank, and acetic acid constitutes feedstock for catalytic reaction. Product of reaction goes through steps that increases ethyl acetate content to 93 percent by weight. To conserve energy, heat exchangers recycle waste heat to preheat process streams at various points.

  20. 21 CFR 173.228 - Ethyl acetate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... the specifications of the Food Chemicals Codex, 1 (Ethyl Acetate; p. 372, 3d Ed., 1981), which are... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Ethyl acetate. 173.228 Section 173.228 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR...

  1. Chromatographic methods for determination of S-substituted cysteine derivatives--a comparative study.

    PubMed

    Kubec, Roman; Dadáková, Eva

    2009-10-01

    A novel HPLC method for determination of a wide variety of S-substituted cysteine derivatives in Allium species has been developed and validated. This method allows simultaneous separation and quantification of S-alk(en)ylcysteine S-oxides, gamma-glutamyl-S-alk(en)ylcysteines and gamma-glutamyl-S-alk(en)ylcysteine S-oxides in a single run. The procedure is based on extraction of these amino acids and dipeptides by methanol, their derivatization by dansyl chloride and subsequent separation by reversed phase HPLC. The main advantages of the new method are simplicity, excellent stability of derivatives, high sensitivity, specificity and the ability to simultaneously analyze the whole range of S-substituted cysteine derivatives. This method was critically compared with other chromatographic procedures used for quantification of S-substituted cysteine derivatives, namely with two other HPLC methods (derivatization by o-phthaldialdehyde/tert-butylthiol and fluorenylmethyl chloroformate), and with determination by gas chromatography or capillary electrophoresis. Major advantages and drawbacks of these analytical procedures are discussed. Employing these various chromatographic methods, the content and relative proportions of individual S-substituted cysteine derivatives were determined in four most frequently consumed alliaceous vegetables (garlic, onion, shallot, and leek). PMID:19733357

  2. Online Measurement of the Intramolecular Isotopic Composition of Acetate in Natural Porewater Samples

    NASA Astrophysics Data System (ADS)

    Thomas, R. B.; Arthur, M. A.; Freeman, K. H.

    2006-12-01

    Carbon dioxide and methane are traditionally considered to be the dominant end products of anaerobic metabolism while acetate is thought to be a rapidly consumed intermediate. However, in some settings, recent evidence has grown to suggest that, at least transiently, acetate can be a major metabolic end product. In natural systems, isotopic mass balances can be used to partition the flow of carbon to methane, CO2, and acetate. However, these isotopic estimates require intramolecular measurements of acetate in addition to isotopic measurements of the gaseous species, CO2 and CH4. In practice, the intramolecular isotopic composition of acetate is rarely measured because the analysis is technically challenging and traditionally requires prior separation and offline pyrolysis of purified acetate. As a result of these technical challenges, acetate methyl carbon is usually assumed to be a few permil depleted relative to the carbon isotopic composition of bulk organic matter. In environments where acetate may be produced by autotrophic acetogens this assumption can be devastatingly false. This work describes the use of an online method for the analysis of the intramolecular carbon isotopic composition of dissolved acetate from dilute surface water samples with a detection limit of injected sample down to 500uM. Preconcentration of samples via lyophilization has resulted in detection limits as low as 30uM. In 2002, at Penn State, Dias et al. (Organic Geochemistry Vol. 33, p161-168) reported a technique to examine the intramolecular isotopic composition of acetate from oil-prone source rocks using SPME extraction with an online GC-pyrolysis-IRMS. We have adapted the Dias method to be used with direct injection of dilute natural water samples. Briefly, this procedure protonates acetate with a .1M addition of oxalic acid and vaporizes the sample in the GC inlet at low temperatures. This prevents oxalic acid decomposition and provides sufficient separation of acetate from

  3. A new process for producing calcium acetate from vegetable wastes for use as an environmentally friendly deicer.

    PubMed

    Jin, Fangming; Zhang, Guangyi; Jin, Yujia; Watanabe, Yosiyuki; Kishita, Atsushi; Enomoto, Heiji

    2010-10-01

    A new process for producing calcium acetate, a non-corrosive deicer, is proposed. The process consists of a two-step continuous-flow hydrothermal conversion of vegetable wastes into acetic acid and the production of calcium acetate, followed by the separation and condensation of the product. The experiments for acetic acid production showed that there were almost no significant differences in acetic acid yields for the five different kinds of vegetables selected for the batch experiments or for their mixture in batch and continuous-flow experiments. Electrodialysis was chosen as a satisfactory method for separating and condensing the calcium acetate produced from the acetic acid solution obtained from the vegetable wastes. After purification by reverse-osmosis, the residual, depleted acid solution could be safely discharged. The calculation of the carbon balance for the proposed process showed that 21.3% of the TOC from vegetable wastes could be used as calcium/magnesium acetate (CMA) and over 22% as an environmentally friendly deicer. PMID:20483594

  4. Hydrogen fluoride capture by imidazolium acetate ionic liquid

    NASA Astrophysics Data System (ADS)

    Chaban, Vitaly

    2015-04-01

    Extraction of hydrofluoric acid (HF) from oils is a drastically important problem in petroleum industry, since HF causes quick corrosion of pipe lines and brings severe health problems to humanity. Some ionic liquids (ILs) constitute promising scavenger agents thanks to strong binding to polar compounds and tunability. PM7-MD simulations and hybrid density functional theory are employed here to consider HF capture ability of ILs. Discussing the effects and impacts of the cation and the anion separately and together, we evaluate performance of imidazolium acetate and outline systematic search guidelines for efficient adsorption and extraction of HF.

  5. Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

    NASA Technical Reports Server (NTRS)

    Mahaffy, P.; Harpold, D.; Niemann, H.; Atreya, S.; Gorevan, S.; Israel, G.; Bertaux, J. L.; Jones, J.; Owen, T.; Raulin, F.

    1999-01-01

    payload based Micromissions, it is essential to implement an even broader chemical analysis and to enable a significant extension of previous isotope measurements. Such a development would enhance the presently very active study of questions of atmospheric evolution and loss and past climatic conditions. The method selected to implement this program can be based on well-established mass spectrometry techniques. Sampled gas is chemically and physically processed to separate the gas mixture into components using gas chromatograph and related enrichment techniques. This allows trace species to be identified and reveals isotopic distributions in many cases with improved precision. Samples of interest, such as organic molecules, may lie deep below the highly oxidized surface layer and the suggested program includes enhanced sampling techniques to measure volatiles preserved in solid phase material deep below the surface as well as gas from the well mixed atmosphere.

  6. [Transfer possibilities of the mobile phases between different liquid chromatographic techniques for the analysis and isolation of compounds of biological matrices].

    PubMed

    Nyiredy, S

    1999-01-01

    After the survey and characterisation of the solid/liquid chromatographic methods, the author summarized the features of overpressure layer chromatography; the disturbing zone and the multi-front effect as well as the elimination of their influence. In light of these effects, the strategy of the mobile phase transfer possibilities is demonstrated between the various analytical and preparative liquid chromatographic methods, with the OPLC playing a central role. The main point of this strategy is that the examination of biological matrices is always begun with unsaturated TLC chamber, in which the compounds to be separated are placed between the Rf values of 0.3 and 0.8. The optimized TLC mobile phase is transferred without changes to the OPLC technique where a prerun is applied. For separation of nonpolar compounds, the prerun can be performed with hexane; for separation of polar substances the prerun can be performed with any component of the mobile phase in which the components are unable to migrate. The selection of this solvent might be considered during optimization of the mobile phase. Using HPTLC chromatoplate and analytical OPLC technique, highly effective separation can be achieved. The scaling-up for the various preparative chromatographic systems can be performed on basis of the applied chromatographic circumstances. The dry-filled preparative (FC, LPLC, MPLC) columns can be equilibrated with the solvent used for the prerun in analytical OPLC, while in case of filling with slurry technique, the slurry has to be prepared using the same solvent as was used for the prerun of OPLC. The air bubbles can be eliminated in both cases by pumping over the appropriate quantity of the solvent used for prerun, afterwards the preparative separation can be started with the optimized unsaturated TLC mobile phase. The author deals separately with the mobile phase transfer possibilities between the different analytical and preparative planar (OPLC and RPC with various

  7. Continuous melting and ion chromatographic analyses of ice cores.

    PubMed

    Huber, T M; Schwikowski, M; Gäggele, H W

    2001-06-22

    A new method for determining concentrations of organic and inorganic ions in ice cores by continuous melting and contemporaneous ion chromatographic analyses was developed. A subcore is melted on a melting device and the meltwater produced is collected in two parallel sample loops and then analyzed simultaneously by two ion chromatographs, one for anions and one for cations. For most of the analyzed species, lower or equal blank values were achieved with the continuous melting and analysis technique compared to the conventional analysis. Comparison of the continuous melting and ion chromatographic analysis with the conventional analysis of a real ice core segment showed good agreement in concentration profiles and total amounts of ionic species. Thus, the newly developed method is well suited for ice core analysis and has the advantages of lower ice consumption, less time-consuming sample preparation and lower risk of contamination. PMID:11452998

  8. The pharmacology of nomegestrol acetate.

    PubMed

    Ruan, Xiangyan; Seeger, Harald; Mueck, Alfred O

    2012-04-01

    Nomegestrol acetate (NOMAC) is a 19-norprogesterone derivative with high biological activity at the progesterone receptor, a weak anti-androgenic effect, but with no binding to estrogen, glucocorticoid or mineralocorticoid receptors. At dosages of 1.5mg/day or more, NOMAC effectively suppresses gonadotropic activity and ovulation in women of reproductive age. Hemostasis, lipids and carbohydrate metabolism remain largely unchanged. In normal and cancerous human breast cells, NOMAC has shown favorable effects on estrogen metabolism. Like natural progesterone (but in contrast to some other synthetic progestogens), it does not appear stimulate the proliferation of cancerous breast cells. While there has been some experience of the use of NOMAC in combination with estrogens as a hormone replacement therapy, most of the data on the compound are reported in the context of its inclusion as a component of a new contraceptive pill comprising 2.5mg NOMAC combined with 1.5mg estradiol. Because of its strong endometrial efficacy, and due to its high antigonadotropic activity and long elimination half-life (about 50h), the contraceptive efficacy of the new pill is maintained even when dosages are missed. Furthermore, for the first time with a monophasic 24/4 regimen containing estradiol, cyclical stability can be achieved comparable with that obtained using pills containing ethinyl estradiol and progestogens like levonorgestrel or drospirenone. The addition of NOMAC to estradiol means that the beneficial effects of estrogen are not lost, which is of especial importance in relation to the cardiovascular system. On the basis both of its pharmacology and of studies performed during the development of the NOMAC/estradiol pill, involving some 4000 women in total, good long-term tolerability can be expected for NOMAC, although its safety profile is still to be fully ascertained, as the clinical endpoint studies are yet to be completed. PMID:22364709

  9. Conversion to eslicarbazepine acetate monotherapy

    PubMed Central

    French, Jacqueline; Jacobson, Mercedes P.; Pazdera, Ladislav; Gough, Mallory; Cheng, Hailong; Grinnell, Todd; Blum, David

    2016-01-01

    Objective: To assess the efficacy and safety of eslicarbazepine acetate (ESL) monotherapy. Methods: This post hoc pooled analysis of 2 randomized double-blind studies (093-045 and -046) included adults with partial-onset seizures medically uncontrolled by 1 or 2 antiepileptic drugs (AEDs). Following the baseline period (8 weeks), eligible patients were randomized 2:1 to receive ESL 1,600 mg or 1,200 mg once daily for 18 weeks; the primary endpoint was study exit by meeting predefined exit criteria (signifying worsening seizure control). In each study, treatment was considered effective if the upper 95% confidence limit for exit rate was lower than the historical control threshold (65.3%). Results: Pooled exit rates were as follows: ESL 1,600 mg = 20.6% (95% confidence interval: 15.6%–26.8%); ESL 1,200 mg = 30.8% (23.0%–40.5%). Use of 2 baseline AEDs or rescue medication, US location, epilepsy duration ≥20 years, and higher maximum baseline seizure frequency were associated with higher exit risks. Median percent reductions in standardized seizure frequency between baseline and the 18-week double-blind period were as follows: ESL 1,600 mg = 43.2%; ESL 1,200 mg = 35.7%; baseline carbamazepine use was associated with smaller reductions. Safety profiles were similar between ESL doses. Conclusions: Exit rates for ESL monotherapy (1,600 mg and 1,200 mg once daily) were lower than the historical control threshold, irrespective of baseline AED use and region, with no additional safety concerns identified. Clinical factors and location clearly influence treatment responses in conversion-to-monotherapy trials. Classification of evidence: This pooled analysis provides Class IV evidence that for adults with medically uncontrolled partial-onset seizures, ESL monotherapy is well tolerated and effective. PMID:26911639

  10. Studies on improved integrated membrane-based chromatographic process for bioseparation

    NASA Astrophysics Data System (ADS)

    Xu, Yanke

    To improve protein separation and purification directly from a fermentation broth, a novel membrane filtration-cum-chromatography device configuration having a relatively impermeable coated zone near the hollow fiber module outlet has been developed. The integrated membrane filtration-cum-chromatography unit packed with chromatographic beads on the shell side of the hollow fiber unit enjoys the advantages of both membrane filtration and chromatography; it allows one to load the chromatographic media directly from the fermentation broth or lysate and separate the adsorbed proteins through the subsequent elution step in a cyclic process. Interfacial polymerization was carried out to coat the bottom section of the hollow fiber membrane while leaving the rest of the hollow fiber membrane unaffected. Myoglobin (Mb), bovine serum albumin (BSA) and a-lactalbumin (a-LA) were used as model proteins in binary mixtures. Separation behaviors of binary protein mixtures were studied in devices using either an ultrafiltration (UF) membrane or a microfiltration (MF) membrane. Experimental results show that the breakthrough time and the protein loading capacities were dramatically improved after coating in both UF and MF modules. For a synthetic yeast fermentation broth feed, the Mb and a-LA elution profiles for the four consecutive cyclic runs were almost superimposable. Due to the lower transmembrane flux in this device plus the periodical washing-elution during the chromatographic separation, fouling was not a problem as it is in conventional microfiltration. A mathematical model describing the hydrodynamic and protein loading behaviors of the integrated device using UF membrane with a coated zone was developed. The simulation results for the breakthrough agree well with the experimental breakthrough curves. The optimal length of the coated zone was obtained from the simulation. A theoretical analysis of the protein mass transfer was performed using a diffusion-convection model

  11. Comparison of enzymatic and liquid chromatographic chloramphenicol assays

    SciTech Connect

    Weber, A.F.; Opheim, K.E.; Koup, J.R.; Smith, A.L.

    1981-02-01

    A radioenzymatic assay and a ''high-performance'' liquid chromatographic assay for chloramphenicol were compared by using 52 patient specimens, 24 mock unknowns, and 13 quality control samples. Both methods were found to be rapid, precise, accurate, and sensitive, and either would be suitable for monitoring chloramphenicol concentrations in small volumes of serum. Linear regression analysis of serum chloramphenicol concentrations in patients receiving chloramphenicol succinate yielded a regression equation of Y . 1.04X + 0.274 (X . high-performance liquid chromatographic assay; Y . radioenzymatic assay), with a correlation coefficient of 0.971.

  12. On-line gas chromatographic analysis of airborne particles

    DOEpatents

    Hering, Susanne V.; Goldstein, Allen H.

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  13. The analysis of the zero-order and the second derivative spectra of retinol acetate, tocopherol acetate and coenzyme Q 10 and estimation of their analytical usefulness for their simultaneous determination in synthetic mixtures and pharmaceuticals

    NASA Astrophysics Data System (ADS)

    Karpińska, Joanna; Mularczyk, Beata

    2004-08-01

    The aim of the present work was to develop a simple and rapid method of retinol acetate, tocopherol acetate and coenzyme Q 10 determination in pharmaceuticals without involving any preparation operations like separation or masking. The values of second derivative amplitude at 212 nm for tocopherol, 351 nm for retinol and 222 nm for coenzyme were used for construction of calibration graphs. Beer's law is obeyed in the concentration range 0.5-20, 0.5-7.5 and 0.5-30 μg ml -1 for retinol acetate, tocopherol acetate and coenzyme, respectively. The elaborated procedures were successfully applied to the simultaneous determination of studied compounds in their binary synthetic mixtures and in commercial preparations with high reliability and repeatability. Spectral properties of retinol acetate allows to determine its contents in ternary mixture which includes Vitamin E and coenzyme Q 10.

  14. Separated flow

    NASA Technical Reports Server (NTRS)

    Sellers, W. L., III; Dunham, R. E., Jr.; Goodman, W. L.; Howard, F. G.; Margason, R. J.; Rudy, D. H.; Rumsey, C. L.; Stough, H. P., III; Thomas, J. L.

    1986-01-01

    A brief overview of flow separation phenomena is provided. Langley has many active research programs in flow separation related areas. Three cases are presented which describe specific examples of flow separation research. In each example, a description of the fundamental fluid physics and the complexity of the flow field is presented along with a method of either reducing or controlling the extent of separation. The following examples are discussed: flow over a smooth surface with an adverse pressure gradient; flow over a surface with a geometric discontinuity; and flow with shock-boundary layer interactions. These results will show that improvements are being made in the understanding of flow separation and its control.

  15. Multivariate analysis of FTIR and ion chromatographic data for the quality control of tequila.

    PubMed

    Lachenmeier, Dirk W; Richling, Elke; López, Mercedes G; Frank, Willi; Schreier, Peter

    2005-03-23

    Principal component analysis (PCA) was applied to the chromatographic and spectroscopic data of authentic Mexican tequilas (n = 14) and commercially available samples purchased in Mexico and Germany (n = 24). The scores scatter plot of the first two principal components (PC) of the anions chloride, nitrate, sulfate, acetate, and oxalate accounting for 78% of the variability allowed a classification between tequilas bottled in Mexico and overseas; however, no discrimination between tequila categories was possible. Mexican products had a significantly (p = 0.0014) lower inorganic anion concentration (range = 1.5-5.1 mg/L; mean = 2.5 mg/L) than the products bottled in the importing countries (range = 3.3-62.6 mg/L; mean = 26.3 mg/L). FTIR allowed a rapid screening of density and ethanol as well as the volatile compounds methanol, ethyl acetate, propanol-1, isobutanol, and 2-/3-methyl-1-butanol using partial least-squares regression (precisions = 5.3-29.3%). Using PCA of the volatile compounds, a differentiation between tequila derived from "100% agave" (Agave tequilana Weber var. azul, Agavaceae) and tequila produced with other fermentable sugars ("mixed"tequila) was possible. The first two PCs describe 89% of the total variability of the data. Methanol and isobutanol influenced the variability in PC1, which led to discrimination. The concentrations of methanol and isobutanol were significantly higher (methanol, p = 0.004; isobutanol, p = 0.005) in the 100% agave (methanol, 297.9 +/- 49.5; isobutanol, 251.3 +/- 34.9) than in the mixed tequilas (methanol, 197.8 +/- 118.5; isobutanol, 151.4 +/- 52.8). PMID:15769149

  16. Chromatographic analysis of 1,3-bis(dimethylamino)isopropyl 4-chlorophenoxyacetate dihydrochloride, a new CNS stimulant.

    PubMed

    Kiss, I T; Kovács-Hadady, K

    1992-01-01

    A reversed-phase liquid chromatographic method is developed for the assay of the new CNS stimulant, 1,3-bis(dimethylamino)isopropyl 4-chlorophenoxyacetate dihydrochloride (BCE-001), and its main contaminant, 4-chlorophenoxyacetic acid (PCPA). In the first place the possible reactions of BCE-001 with mobile phase components are investigated and it is found that BCE-001 is readily hydrolysed in water and undergoes transesterification in methanol or ethanol. The methyl ester is formed rapidly and quantitatively so that BCE-001 can be assayed as methyl 4-chlorophenoxyacetate. PCPA is formed as a result of the hydrolysis of BCE-001 during the sample pretreatment and chromatographic separation and this causes an overestimate of the PCPA impurity in the bulk drug. An effective method is developed to prevent the hydrolysis of BCE-001 during sample pretreatment. PMID:1391102

  17. Quantitative liquid chromatographic determination of cefatrizine in serum and urine by fluorescence detection after post-column derivatization.

    PubMed

    Crombez, E; Van der Weken, G; Van den Bossche, W; De Moerloose, P

    1979-09-21

    A fast, specific and sensitive high-performance liquid chromatographic procedure for the determination of cefatrizine, an orally active cephalosporin, in serum and urine is proposed. The drug is determined by the internal standard method, using cephradine as the internal standard. The separation is carried out on a reversed-phase column, filled with octadecylsilane chemically bonded microparticles. The eluent is a mixture of acetonitrile with 0.025 M sodium phosphate buffer (pH 7). Quantitation is effected by fluorescence detection of the fluorophores formed after post-column derivatization with fluorescamine in a packed-bed reactor. The chromatographic conditions and the conditions for the post-column derivatization are discussed. The method has been applied to serum and urine samples, which were analysed after deproteinization with trichloroacetic acid and injection of the clear supernatant. The accuracy and reproducibility of the procedure were investigated by the determination of the cefatrizine content in spiked serum and urine samples. PMID:528641

  18. Clostridium thermosaccharolyticum strain deficient in acetate production

    SciTech Connect

    Rothstein, D.M.

    1986-01-01

    A mutant of Clostridium thermosaccharolyticum that is blocked in acetate production was isolated after treatment with nitrosoguanidine and selection for fluoroacetate resistance. The mutant produced more ethanol than the parent strain did.

  19. Acetate Causes Alcohol Hangover Headache in Rats

    PubMed Central

    Maxwell, Christina R.; Spangenberg, Rebecca Jay; Hoek, Jan B.; Silberstein, Stephen D.; Oshinsky, Michael L.

    2010-01-01

    Background The mechanism of veisalgia cephalgia or hangover headache is unknown. Despite a lack of mechanistic studies, there are a number of theories positing congeners, dehydration, or the ethanol metabolite acetaldehyde as causes of hangover headache. Methods We used a chronic headache model to examine how pure ethanol produces increased sensitivity for nociceptive behaviors in normally hydrated rats. Results Ethanol initially decreased sensitivity to mechanical stimuli on the face (analgesia), followed 4 to 6 hours later by inflammatory pain. Inhibiting alcohol dehydrogenase extended the analgesia whereas inhibiting aldehyde dehydrogenase decreased analgesia. Neither treatment had nociceptive effects. Direct administration of acetate increased nociceptive behaviors suggesting that acetate, not acetaldehyde, accumulation results in hangover-like hypersensitivity in our model. Since adenosine accumulation is a result of acetate formation, we administered an adenosine antagonist that blocked hypersensitivity. Discussion Our study shows that acetate contributes to hangover headache. These findings provide insight into the mechanism of hangover headache and the mechanism of headache induction. PMID:21209842

  20. Mafenide acetate allergy presenting as recurrent chondritis.

    PubMed

    Pickus, Evan J; Lionelli, Gerald T; Charles, E Woodall; Korentager, Richard A

    2002-02-01

    Acute chondritis has a strong predilection for recurrence. Mafenide acetate has been implicated in causing reactions that mimic this condition; however, these hypersensitivity reactions lack fever, fluctuance, and pain. The authors report a case of mafenide acetate allergy presenting as recurrent chondritis in a patient who had previously been treated successfully for this condition. In this patient, the allergic response resolved within 3 days after cessation of mafenide acetate. If unappreciated, it may have led to unnecessary operative intervention. Therefore, auricular edema and erythema, without fever, fluctuance, and pain, must be recognized by surgeons as a possible mafenide acetate allergy and must be considered in the differential diagnosis for patients who present with recurrent acute suppurative chondritis. PMID:11910229

  1. Nomegestrol acetate/estradiol: in oral contraception.

    PubMed

    Yang, Lily P H; Plosker, Greg L

    2012-10-01

    Nomegestrol acetate/estradiol is a combined oral contraceptive with approval in many countries. This fixed-dose combination tablet contains nomegestrol acetate, a highly selective progestogen, and estradiol, a natural estrogen. It is the first monophasic combined oral contraceptive to contain estradiol, and is taken in 28-day cycles, consisting of 24 active therapy days with 4 placebo days (i.e. 24/4-day cycles). In two large, 1-year, randomized, open-label, multicentre, phase III trials in healthy adult women (aged 18-50 years), nomegestrol acetate/estradiol was at least as effective as drospirenone/ethinylestradiol as contraceptive therapy, as the pregnancy rates in women aged 18-35 years (primary efficacy population) in terms of the Pearl Index (primary endpoint) were numerically lower with nomegestrol acetate/estradiol, although the between-group difference was not statistically significant. In both trials, nomegestrol acetate/estradiol was given in a 24/4-day cycle, and drospirenone/ethinylestradiol was given in a 21/7-day cycle. The criteria for using condoms in case of forgotten doses were less stringent in the nomegestrol acetate/estradiol group than in the drospirenone/ethinylestradiol group. Nomegestrol acetate/estradiol therapy for up to 1 year was generally well tolerated in healthy adult women, with an acceptable tolerability profile in line with that expected for a combined oral contraceptive. The most commonly reported adverse events were acne and abnormal withdrawal bleeding (most often shorter, lighter or absent periods). Overall, compared with drospirenone/ethinylestradiol, nomegestrol acetate/estradiol appeared to be associated with less favourable acne-related outcomes, and shorter, lighter or absent periods. PMID:22950535

  2. Methanogenesis from acetate: a nonmethanogenic bacterium from an anaerobic acetate enrichment.

    PubMed

    Ward, D M; Mah, R A; Kaplan, I R

    1978-06-01

    A methanogenic acetate enrichment was initiated by inoculation of an acetate-mineral salts medium with domestic anaerobic digestor sludge and maintained by weekly transfer for 2 years. The enrichment culture contained a Methanosarcina and several obligately anaerobic nonmethanogenic bacteria. These latter organisms formed varying degrees of association with the Methanosarcina, ranging from the nutritionally fastidious gram-negative rod called the satellite bacterium to the nutritionally nonfastidious Eubacterium limosum. The satellite bacterium had growth requirements for amino acids, a peptide, a purine base, vitamin B12, and other B vitamins. Glucose, mannitol, starch, pyruvate, cysteine, lysine, leucine, isoleucine, arginine, and asparagine stimulated growth and hydrogen production. Acetate was neither incorporated nor metabolized by the satellite organism. Since acetate was the sole organic carbon source in the enrichment culture, organism(s) which metabolize acetate (such as the Methanosarcina) must produce substrates and growth factors for associated organisms which do not metabolize acetate. PMID:677881

  3. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    USGS Publications Warehouse

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  4. Chromatographic resolution of closely related species in pharmaceutical chemistry: dehalogenation impurities and mixtures of halogen isomers.

    PubMed

    Regalado, Erik L; Zhuang, Ping; Chen, Yadan; Makarov, Alexey A; Schafer, Wes A; McGachy, Neil; Welch, Christopher J

    2014-01-01

    In recent years, the use of halogen-containing molecules has proliferated in the pharmaceutical industry, where the incorporation of halogens, especially fluorine, has become vitally important for blocking metabolism and enhancing the biological activity of pharmaceuticals. The chromatographic separation of halogen-containing pharmaceuticals from associated isomers or dehalogenation impurities can sometimes be quite difficult. In an attempt to identify the best current tools available for addressing this important problem, a survey of the suitability of four chromatographic method development platforms (ultra high-performance liquid chromatography (UHPLC), core shell HPLC, achiral supercritical fluid chromatography (SFC) and chiral SFC) for separating closely related mixtures of halogen-containing pharmaceuticals and their dehalogenated isosteres is described. Of the 132 column and mobile phase combinations examined for each mixture, a small subset of conditions were found to afford the best overall performance, with a single UHPLC method (2.1 × 50 mm, 1.9 μm Hypersil Gold PFP, acetonitrile/methanol based aqueous eluents containing either phosphoric or perchloric acid with 150 mM sodium perchlorate) affording excellent separation for all samples. Similarly, a survey of several families of closely related halogen-containing small molecules representing the diversity of impurities that can sometimes be found in purchased starting materials for synthesis revealed chiral SFC (Chiralcel OJ-3 and Chiralpak IB, isopropanol or ethanol with 25 mM isobutylamine/carbon dioxide) as well as the UHPLC (2.1 × 50 mm, 1.8 μm ZORBAX RRHD Eclipse Plus C18 and the Gold PFP, acetonitrile/methanol based aqueous eluents containing phosphoric acid) as preferred methods. PMID:24359254

  5. Automatic segmentation of chromatographic images for region of interest delineation

    NASA Astrophysics Data System (ADS)

    Mendonça, Ana M.; Sousa, António V.; Sá-Miranda, M. Clara; Campilho, Aurélio C.

    2011-03-01

    This paper describes a segmentation method for automating the region of interest (ROI) delineation in chromatographic images, thus allowing the definition of the image area that contains the fundamental information for further processing while excluding the frame of the chromatographic plate that does not contain relevant data for disease identification. This is the first component of a screening tool for Fabry disease, which will be based on the automatic analysis of the chromatographic patterns extracted from the image ROI. Image segmentation is performed in two phases, where each individual pixel is finally considered as frame or ROI. In the first phase, an unsupervised learning method is used for classifying image pixels into three classes: frame, ROI or unknown. In the second phase, distance features are used for deciding which class the unknown pixels belong to. The segmentation result is post-processed using a sequence of morphological operators in order to obtain the final ROI rectangular area. The proposed methodology was successfully evaluated in a dataset of 41 chromatographic images.

  6. GAS CHROMATOGRAPHIC MICROMETHOD FOR TRACE DETERMINATIONS OF PHENOLS

    EPA Science Inventory

    A gas chromatographic procedure is described for the analysis of a variety of substituted phenols from water samples. The method was designed for situations when the sample size is very limited (0.5 to 1.0 ml), such as in laboratory microcosm experiments on transport and fate of ...

  7. Chromatographic profiles of Ginkgo biloba leaves and selected products

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An LC-DAD-ESI/MS method was developed to obtain chromatographic profiles for the flavonoids and terpene lactones of Ginkgo biloba leaves and selected G. biloba products. The method was used to identify 46 glycosylated flavonols and flavones, 3 free flavonol aglycones, catechin, 10 biflavones, a dihy...

  8. Chromatographic fingerprints analysis for evaluation of Ginkgo Biloba products

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The leaf extract of Ginkgo biloba has purported value for improving mental capacities in Alzheimer’s patients. The flavonoids and the terpene lactones are considered to be the two main active components that influence human health. This paper compared an LC/UV chromatographic fingerprint method wi...

  9. [A gas chromatographic method for determining acetaldehyde in cadaver blood].

    PubMed

    Savich, V I; Valladares, Kh A; Gusakov, Iu A; Skachko, Z M

    1990-01-01

    Gas-chromatographic method of acetaldehyde detection in blood of subjects who died of alcoholic intoxication is suggested. Method is simple, does not require additional expenses, can be readily used in medicolegal practice and in difficult cases it may help the expert to make an objective conclusion on the cause of death. PMID:2087747

  10. Bioanalytical method transfer considerations of chromatographic-based assays.

    PubMed

    Williard, Clark V

    2016-07-01

    Bioanalysis is an important part of the modern drug development process. The business practice of outsourcing and transferring bioanalytical methods from laboratory to laboratory has increasingly become a crucial strategy for successful and efficient delivery of therapies to the market. This chapter discusses important considerations when transferring various types of chromatographic-based assays in today's pharmaceutical research and development environment. PMID:27277876

  11. Note on the chromatographic analyses of marine polyunsaturated fatty acids

    USGS Publications Warehouse

    Schultz, D.M.; Quinn, J.G.

    1977-01-01

    Gas-liquid chromatography was used to study the effects of saponification/methylation and thin-layer chromatographic isolation on the analyses of polyunsaturated fatty acids. Using selected procedures, the qualitative and quantitative distribution of these acids in marine organisms can be determined with a high degree of accuracy. ?? 1977 Springer-Verlag.

  12. Confocal Raman microscopy of protein adsorbed in chromatographic particles.

    PubMed

    Xiao, Yuewu; Stone, Thomas; Bell, David; Gillespie, Christopher; Portoles, Marta

    2012-09-01

    Confocal Raman microscopy is a nondestructive analytical technique that combines the chemical information from vibrational spectroscopy with the spatial resolution of confocal microscopy. It was applied, for the first time, to measure conformation and distribution of protein adsorbed in wetted chromatographic particles. Monoclonal antibody was loaded into the Fractogel EMD SO(3) (M) cation exchanger at 2 mS/cm or 10 mS/cm. Amide I and III frequencies in the Raman spectrum of the adsorbed protein suggest that there are no detectable changes of the original β-sheet conformation in the chromatographic particles. Protein depth profile measurements indicate that, when the conductivity is increased from 2 mS/cm to 10 mS/cm, there is a change in mass transport mechanism for protein adsorption, from the shrinking-core model to the homogeneous-diffusion model. In this study, the use of confocal Raman microscopy to measure protein distribution in chromatographic particles fundamentally agrees with previous confocal laser scanning microscopic investigations, but confocal Raman spectroscopy enjoys additional advantages: use of unlabeled protein to eliminate fluorescent labeling, ability for characterization of protein secondary structure, and ability for spectral normalization to provide a nondestructive experimental approach to correct light attenuation effects caused by refractive index (RI) mismatching in semiopaque chromatographic particles. PMID:22803776

  13. Gas chromatographic column for the Viking 1975 molecular analysis experiment

    NASA Technical Reports Server (NTRS)

    Novotny, M.; Hayes, J. M.; Bruner, F.; Simmonds, P. G.

    1975-01-01

    A gas chromatographic column has been developed for use in the remote analysis of the Martian surface. The column, which utilizes a liquid-modified organic adsorbent (Tenax) as the stationary phase, provides efficient transmission and resolution of nanogram quantities of organic materials in the presence of millionfold excesses of water and carbon dioxide.

  14. Economic gas chromatograph system for subambient pressure gas sampling

    NASA Technical Reports Server (NTRS)

    Mitchell, S. M.

    1970-01-01

    Gas chromatograph sampling system consists of a manifold with a gas-sample valve, a minimum-volume pressure transducer with a portable monitor, a vacuum-source valve, and a sample inlet valve. Increased accuracy of analysis is obtained by better control of sample size.

  15. Direct zonal liquid chromatographic method for the kinetic study of actinomycin-DNA binding.

    PubMed

    Vidal-Madjar, Claire; Florentina, Cañada-Cañada; Gherghi, Ioanna; Jaulmes, Alain; Pantazaki, Anastasia; Taverna, Myriam

    2004-07-01

    The binding of an anticancer drug (actinomycin D or ACTD) to double-stranded DNA (dsDNA) was studied by means of high-performance liquid chromatography (HPLC). ACTD is an antitumor antibiotic containing one chromophore group and two pentapeptidic lactone cycles that binds dsDNA. Incubations of ACTD with DNA were performed at physiological pH. The complexed and free ligand concentrations of the mixture were quantified at 440 nm from their separation on a size-exclusion chromatographic (SEC) column using the same buffer for the elution and the sample incubation. The DNA and the ACTD-DNA complexes were eluted at the column exclusion volume while the ligand was retained on the support. An apparent binding curve was obtained by plotting the amount emerging at the exclusion column volume against that eluted at free ACTD retention volume. A dissociating effect was evidenced and the binding parameters were significantly different from those obtained at equilibrium by visible absorbance titration. The equilibrium binding parameters determined by absorption spectroscopy were used as starting data in the numerical simulations of the chromatographic process. The results showed a strong dependency of the apparent binding parameters on the reaction kinetics. Finally the comparison of the apparent binding curve obtained from the HPLC experiments and from the numerical simulations permitted an evaluation of the dissociation rate constant (kd = 0.004 s(-1)). PMID:15296384

  16. Decomposition of pilocarpine eye drops assessed by a highly efficient high pressure liquid chromatographic method.

    PubMed

    Kuks, P F; Weekers, L E; Goldhoorn, P B

    1990-10-19

    A rapid high-resolution high pressure liquid chromatographic method was developed for assaying pilocarpine. Pilocarpine in ophthalmic solutions decomposes fairly rapidly to give isopilocarpine, pilocarpic acid and isopilocarpic acid. The quality of an ophthalmic solution can be assessed by assaying these decomposition products. Existing high pressure liquid chromatographic methods suffer from long analysis times and poor resolution. The new method uses as the mobile phase 6 ml/l of triethylamine in water (pH 2.3, adjusted with 85% phosphoric acid) at a flow of 1.5 ml/min and as the stationary phase a C18-silica 125 x 4.6 mm column. 2-Amino-1-phenyl-1,3-propanediol is used as an internal standard. Complete separation was obtained within 8 min. Pilocarpine eye drops were stored under different conditions and then analysed for decomposition products. During heat treatment, decomposition to isopilocarpine predominated over decomposition to pilocarpic or isopilocarpic acid. However, when stored at room temperature or in a refrigerator, formation of pilocarpic acid clearly prevailed. Thus, from assessment of decomposition products, the cause of decomposition can be established. PMID:2255589

  17. Reverse phase liquid chromatographic assay for calcium pantothenate in multivitamin preparations and raw materials.

    PubMed

    Timmons, J A; Meyer, J C; Steible, D J; Assenza, S P

    1987-01-01

    A reverse phase liquid chromatographic (LC) method has been developed for the assay of calcium pantothenate in commercial multivitamin tablet formulations and raw materials. The assay was validated according to the Pharmaceutical Manufacturers Association Quality Control HPLC Committee guidelines. The chromatographic system includes a C-18 column and a mobile phase consisting of 0.25M sodium phosphate buffer, pH 2.5, and acetonitrile (97 + 3 v/v). The column effluent is monitored by UV detection at 205 nm. The sample preparation involves only extraction in water followed by filtration. The method is stability-indicating with a detection limit of approximately 50 ng/mL of the calcium pantothenate in the samples. The system is linear from at least 0.02 to 0.10 mg/mL. The mean recovery of spiked placebos ranged from 98.7 to 99.8%. The within-day precision of the assay on finished products (N = 6) ranged from 0.3 to 2.0% CV. A system suitability criterion for resolution is based on the separation between calcium pantothenate and 2 closely eluting compounds, saccharin and a saccharin degradation product, 2-sulfamoylbenzoic acid. PMID:3610964

  18. Artificial neural network model for photosynthetic pigments identification using multi wavelength chromatographic data

    NASA Astrophysics Data System (ADS)

    Prilianti, K. R.; Hariyanto, S.; Natali, F. D. D.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2016-04-01

    The development of rapid and automatic pigment characterization method become an important issue due to the fact that there are only less than 1% of plant pigments in the earth have been explored. In this research, a mathematical model based on artificial intelligence approach was developed to simplify and accelerate pigment characterization process from HPLC (high-performance liquid chromatography) procedure. HPLC is a widely used technique to separate and identify pigments in a mixture. Input of the model is chromatographic data from HPLC device and output of the model is a list of pigments which is the spectrum pattern is discovered in it. This model provides two dimensional (retention time and wavelength) fingerprints for pigment characterization which is proven to be more accurate than one dimensional fingerprint (fixed wavelength). Moreover, by mimicking interconnection of the neuron in the nervous systems of the human brain, the model have learning ability that could be replacing expert judgement on evaluating spectrum pattern. In the preprocessing step, principal component analysis (PCA) was used to reduce the huge dimension of the chromatographic data. The aim of this step is to simplify the model and accelerate the identification process. Six photosynthetic pigments i.e. zeaxantin, pheophytin a, α-carotene, β-carotene, lycopene and lutein could be well identified by the model with accuracy up to 85.33% and processing time less than 1 second.

  19. High-performance liquid chromatographic determination of naltrexone in plasma of hemodialysis patients.

    PubMed

    Kambia, K; Bah, S; Dine, T; Azar, R; Odou, P; Gressier, B; Luyckx, M; Brunet, C; Ballester, L; Cazin, M; Cazin, J C

    2000-05-01

    A simple, sensitive, selective and reliable reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection is described for the determination of naltrexone in plasma samples. Naltrexone and the internal standard, naloxone, were isolated from plasma either with a liquid-liquid extraction method using ethyl acetate or with a solid-phase extraction method using Sep-Pack C18 cartridge before chromatography. The extracts were dried under a stream of nitrogen and the samples were reconstituted in the mobile phase, then 20 microL were injected on a Waters Symmetry C18 column (5 microm particle size, 4.6 x 150 mm). The mobile phase consisted of 0.06% triethylamine (pH 2.8)-acetonitrile (92:8, v/v) pumped at 1 mL/min. The peak-area ratio versus plasma concentration was linear over the range of 10-500 ng/mL and the detection limit was less than 8 ng/mL. Quantification was by ultra-violet detection at 204 nm. The present method was applied to the determination of the plasma concentration of naltrexone in dialyzed patients. Patients (n = 8) with severe generalized pruritus received 50 mg of naltrexone orally per day for 2 weeks. The variability in the therapeutic response in treated patients required plasma concentration investigations of this opioid antagonist. PMID:10850617

  20. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    PubMed

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including