Science.gov

Sample records for achieved high sensitivity

  1. A luciferin analogue generating near-infrared bioluminescence achieves highly sensitive deep-tissue imaging.

    PubMed

    Kuchimaru, Takahiro; Iwano, Satoshi; Kiyama, Masahiro; Mitsumata, Shun; Kadonosono, Tetsuya; Niwa, Haruki; Maki, Shojiro; Kizaka-Kondoh, Shinae

    2016-01-01

    In preclinical cancer research, bioluminescence imaging with firefly luciferase and D-luciferin has become a standard to monitor biological processes both in vitro and in vivo. However, the emission maximum (λmax) of bioluminescence produced by D-luciferin is 562 nm where light is not highly penetrable in biological tissues. This emphasizes a need for developing a red-shifted bioluminescence imaging system to improve detection sensitivity of targets in deep tissue. Here we characterize the bioluminescent properties of the newly synthesized luciferin analogue, AkaLumine-HCl. The bioluminescence produced by AkaLumine-HCl in reactions with native firefly luciferase is in the near-infrared wavelength ranges (λmax=677 nm), and yields significantly increased target-detection sensitivity from deep tissues with maximal signals attained at very low concentrations, as compared with D-luciferin and emerging synthetic luciferin CycLuc1. These characteristics offer a more sensitive and accurate method for non-invasive bioluminescence imaging with native firefly luciferase in various animal models. PMID:27297211

  2. A luciferin analogue generating near-infrared bioluminescence achieves highly sensitive deep-tissue imaging.

    PubMed

    Kuchimaru, Takahiro; Iwano, Satoshi; Kiyama, Masahiro; Mitsumata, Shun; Kadonosono, Tetsuya; Niwa, Haruki; Maki, Shojiro; Kizaka-Kondoh, Shinae

    2016-06-14

    In preclinical cancer research, bioluminescence imaging with firefly luciferase and D-luciferin has become a standard to monitor biological processes both in vitro and in vivo. However, the emission maximum (λmax) of bioluminescence produced by D-luciferin is 562 nm where light is not highly penetrable in biological tissues. This emphasizes a need for developing a red-shifted bioluminescence imaging system to improve detection sensitivity of targets in deep tissue. Here we characterize the bioluminescent properties of the newly synthesized luciferin analogue, AkaLumine-HCl. The bioluminescence produced by AkaLumine-HCl in reactions with native firefly luciferase is in the near-infrared wavelength ranges (λmax=677 nm), and yields significantly increased target-detection sensitivity from deep tissues with maximal signals attained at very low concentrations, as compared with D-luciferin and emerging synthetic luciferin CycLuc1. These characteristics offer a more sensitive and accurate method for non-invasive bioluminescence imaging with native firefly luciferase in various animal models.

  3. A luciferin analogue generating near-infrared bioluminescence achieves highly sensitive deep-tissue imaging

    PubMed Central

    Kuchimaru, Takahiro; Iwano, Satoshi; Kiyama, Masahiro; Mitsumata, Shun; Kadonosono, Tetsuya; Niwa, Haruki; Maki, Shojiro; Kizaka-Kondoh, Shinae

    2016-01-01

    In preclinical cancer research, bioluminescence imaging with firefly luciferase and D-luciferin has become a standard to monitor biological processes both in vitro and in vivo. However, the emission maximum (λmax) of bioluminescence produced by D-luciferin is 562 nm where light is not highly penetrable in biological tissues. This emphasizes a need for developing a red-shifted bioluminescence imaging system to improve detection sensitivity of targets in deep tissue. Here we characterize the bioluminescent properties of the newly synthesized luciferin analogue, AkaLumine-HCl. The bioluminescence produced by AkaLumine-HCl in reactions with native firefly luciferase is in the near-infrared wavelength ranges (λmax=677 nm), and yields significantly increased target-detection sensitivity from deep tissues with maximal signals attained at very low concentrations, as compared with D-luciferin and emerging synthetic luciferin CycLuc1. These characteristics offer a more sensitive and accurate method for non-invasive bioluminescence imaging with native firefly luciferase in various animal models. PMID:27297211

  4. Superconductive quantum interference magnetometer with high sensitivity achieved by an induced resonance

    SciTech Connect

    Vettoliere, A.; Granata, C.

    2014-08-15

    A fully integrated low noise superconducting quantum interference device (SQUID) in a magnetometer configuration is presented. An intrinsic high voltage responsivity as high as 500 μV/Φ{sub 0} has been obtained by introducing a resonance in the voltage – magnetic flux characteristic. This resonance is induced by an integrated superconducting coil surrounding the pick-up coil and connected to one end of the SQUID output. The SQUID magnetometer exhibits a spectral density of magnetic field noise as low as 3 fT/Hz{sup 1/2}. In order to verify the suitability of the magnetometer, measurements of bandwidth and slew rate have been performed and compared with those of the same device without the resonance and with additional positive feedback. Due to their good characteristics such devices can be employed in a large number of applications including biomagnetism.

  5. Superconductive quantum interference magnetometer with high sensitivity achieved by an induced resonance.

    PubMed

    Vettoliere, A; Granata, C

    2014-08-01

    A fully integrated low noise superconducting quantum interference device (SQUID) in a magnetometer configuration is presented. An intrinsic high voltage responsivity as high as 500 μV/Φ0 has been obtained by introducing a resonance in the voltage - magnetic flux characteristic. This resonance is induced by an integrated superconducting coil surrounding the pick-up coil and connected to one end of the SQUID output. The SQUID magnetometer exhibits a spectral density of magnetic field noise as low as 3 fT/Hz(1/2). In order to verify the suitability of the magnetometer, measurements of bandwidth and slew rate have been performed and compared with those of the same device without the resonance and with additional positive feedback. Due to their good characteristics such devices can be employed in a large number of applications including biomagnetism.

  6. Predictive models of lameness in dairy cows achieve high sensitivity and specificity with force measurements in three dimensions.

    PubMed

    Dunthorn, Jason; Dyer, Robert M; Neerchal, Nagaraj K; McHenry, Jonathan S; Rajkondawar, Parimal G; Steingraber, Gary; Tasch, Uri

    2015-11-01

    Lameness remains a significant cause of production losses, a growing welfare concern and may be a greater economic burden than clinical mastitis . A growing need for accurate, continuous automated detection systems continues because US prevalence of lameness is 12.5% while individual herds may experience prevalence's of 27.8-50.8%. To that end the first force-plate system restricted to the vertical dimension identified lame cows with 85% specificity and 52% sensitivity. These results lead to the hypothesis that addition of transverse and longitudinal dimensions could improve sensitivity of lameness detection. To address the hypothesis we upgraded the original force plate system to measure ground reaction forces (GRFs) across three directions. GRFs and locomotion scores were generated from randomly selected cows and logistic regression was used to develop a model that characterised relationships of locomotion scores to the GRFs. This preliminary study showed 76 variables across 3 dimensions produced a model with greater than 90% sensitivity, specificity, and area under the receiver operating curve (AUC). The result was a marked improvement on the 52% sensitivity, and 85% specificity previously observed with the 1 dimensional model or the 45% sensitivities reported with visual observations. Validation of model accuracy continues with the goal to finalise accurate automated methods of lameness detection. PMID:26278403

  7. Evaluating the Instructional Sensitivity of Four States' Student Achievement Tests

    ERIC Educational Resources Information Center

    Polikoff, Morgan S.

    2016-01-01

    As state tests of student achievement are used for an increasingly wide array of high- and low-stakes purposes, evaluating their instructional sensitivity is essential. This article uses data from the Bill and Melinda Gates Foundation's Measures of Effective Project to examine the instructional sensitivity of 4 states' mathematics and English…

  8. Poor Results for High Achievers

    ERIC Educational Resources Information Center

    Bui, Sa; Imberman, Scott; Craig, Steven

    2012-01-01

    Three million students in the United States are classified as gifted, yet little is known about the effectiveness of traditional gifted and talented (G&T) programs. In theory, G&T programs might help high-achieving students because they group them with other high achievers and typically offer specially trained teachers and a more advanced…

  9. High-Sensitivity Microwave Optics.

    ERIC Educational Resources Information Center

    Nunn, W. M., Jr.

    1981-01-01

    Describes a 3.33-cm wavelength (9 GHz) microwave system that achieves a high overall signal sensitivity and a well-collimated beam with moderate-size equipment. The system has been used to develop microwave versions of the Michelson interferometer, Bragg reflector, Brewster's law and total internal reflection, and Young's interference experiment.…

  10. High-Sensitivity Spectrophotometry.

    ERIC Educational Resources Information Center

    Harris, T. D.

    1982-01-01

    Selected high-sensitivity spectrophotometric methods are examined, and comparisons are made of their relative strengths and weaknesses and the circumstances for which each can best be applied. Methods include long path cells, noise reduction, laser intracavity absorption, thermocouple calorimetry, photoacoustic methods, and thermo-optical methods.…

  11. Smart and Bored: Are We Failing Our High Achievers?

    ERIC Educational Resources Information Center

    Cleaver, Samantha

    2008-01-01

    Some high achievers are not as easy to engage. Sometimes motivating high achievers is "a matter of being more sensitive to what they are interested in," says Don Ambrose, a professor of education at Rider University in New Jersey. But too often classrooms are not set up for that kind of sensitivity. Research shows that schools are consistently…

  12. Synthesis of grafted phosphorylcholine polymer layers as specific recognition ligands for C-reactive protein focused on grafting density and thickness to achieve highly sensitive detection.

    PubMed

    Kamon, Yuri; Kitayama, Yukiya; Itakura, Akiko N; Fukazawa, Kyoko; Ishihara, Kazuhiko; Takeuchi, Toshifumi

    2015-04-21

    We studied the effects of layer thickness and grafting density of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) thin layers as specific ligands for the highly sensitive binding of C-reactive protein (CRP). PMPC layer thickness was controlled by surface-initiated activators generated by electron transfer for atom transfer radical polymerization (AGET ATRP). PMPC grafting density was controlled by utilizing mixed self-assembled monolayers with different incorporation ratios of the bis[2-(2-bromoisobutyryloxy)undecyl] disulfide ATRP initiator, as modulated by altering the feed molar ratio with (11-mercaptoundecyl)tetra(ethylene glycol). X-ray photoelectron spectroscopy and ellipsometry measurements were used to characterize the modified surfaces. PMPC grafting densities were estimated from polymer thickness and the molecular weight obtained from sacrificial initiator during surface-initiated AGET ATRP. The effects of thickness and grafting density of the obtained PMPC layers on CRP binding performance were investigated using surface plasmon resonance employing a 10 mM Tris-HCl running buffer containing 140 mM NaCl and 2 mM CaCl2 (pH 7.4). Furthermore, the non-specific binding properties of the obtained layers were investigated using human serum albumin (HSA) as a reference protein. The PMPC layer which has 4.6 nm of thickness and 1.27 chains per nm(2) of grafting density showed highly sensitive CRP detection (limit of detection: 4.4 ng mL(-1)) with low non-specific HSA adsorption, which was improved 10 times than our previous report of 50 ng mL(-1). PMID:25783194

  13. Synthesis of grafted phosphorylcholine polymer layers as specific recognition ligands for C-reactive protein focused on grafting density and thickness to achieve highly sensitive detection.

    PubMed

    Kamon, Yuri; Kitayama, Yukiya; Itakura, Akiko N; Fukazawa, Kyoko; Ishihara, Kazuhiko; Takeuchi, Toshifumi

    2015-04-21

    We studied the effects of layer thickness and grafting density of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC) thin layers as specific ligands for the highly sensitive binding of C-reactive protein (CRP). PMPC layer thickness was controlled by surface-initiated activators generated by electron transfer for atom transfer radical polymerization (AGET ATRP). PMPC grafting density was controlled by utilizing mixed self-assembled monolayers with different incorporation ratios of the bis[2-(2-bromoisobutyryloxy)undecyl] disulfide ATRP initiator, as modulated by altering the feed molar ratio with (11-mercaptoundecyl)tetra(ethylene glycol). X-ray photoelectron spectroscopy and ellipsometry measurements were used to characterize the modified surfaces. PMPC grafting densities were estimated from polymer thickness and the molecular weight obtained from sacrificial initiator during surface-initiated AGET ATRP. The effects of thickness and grafting density of the obtained PMPC layers on CRP binding performance were investigated using surface plasmon resonance employing a 10 mM Tris-HCl running buffer containing 140 mM NaCl and 2 mM CaCl2 (pH 7.4). Furthermore, the non-specific binding properties of the obtained layers were investigated using human serum albumin (HSA) as a reference protein. The PMPC layer which has 4.6 nm of thickness and 1.27 chains per nm(2) of grafting density showed highly sensitive CRP detection (limit of detection: 4.4 ng mL(-1)) with low non-specific HSA adsorption, which was improved 10 times than our previous report of 50 ng mL(-1).

  14. Mathematics Achievement in High- and Low-Achieving Secondary Schools

    ERIC Educational Resources Information Center

    Mohammadpour, Ebrahim; Shekarchizadeh, Ahmadreza

    2015-01-01

    This paper identifies the amount of variance in mathematics achievement in high- and low-achieving schools that can be explained by school-level factors, while controlling for student-level factors. The data were obtained from 2679 Iranian eighth graders who participated in the 2007 Trends in International Mathematics and Science Study. Of the…

  15. Self Regulated Learning of High Achievers

    ERIC Educational Resources Information Center

    Rathod, Ami

    2010-01-01

    The study was conducted on high achievers of Senior Secondary school. Main objectives were to identify the self regulated learners among the high achievers, to find out dominant components and characteristics operative in self regulated learners and to compare self regulated learning of learners with respect to their subject (science and non…

  16. TEACH (Train to Enable/Achieve Culturally Sensitive Healthcare)

    NASA Technical Reports Server (NTRS)

    Maulitz, Russell; Santarelli, Thomas; Barnieu, Joanne; Rosenzweig, Larry; Yi, Na Yi; Zachary, Wayne; OConnor, Bonnie

    2010-01-01

    Personnel from diverse ethnic and demographic backgrounds come together in both civilian and military healthcare systems, facing diagnoses that at one level are equalizers: coronary disease is coronary disease, breast cancer is breast cancer. Yet the expression of disease in individuals from different backgrounds, individual patient experience of disease as a particular illness, and interactions between patients and providers occurring in any given disease scenario, all vary enormously depending on the fortuity of the equation of "which patient happens to arrive in whose exam room." Previously, providers' absorption of lessons-learned depended on learning as an apprentice would when exposed over time to multiple populations. As a result, and because providers are often thrown into situations where communications falter through inadequate direct patient experience, diversity in medicine remains a training challenge. The questions then become: Can simulation and virtual training environments (VTEs) be deployed to short-track and standardize this sort of random-walk problem? Can we overcome the unevenness of training caused by some providers obtaining the valuable exposure to diverse populations, whereas others are left to "sink or swim"? This paper summarizes developing a computer-based VTE called TEACH (Training to Enable/Achieve Culturally Sensitive Healthcare). TEACH was developed to enhance healthcare providers' skills in delivering culturally sensitive care to African-American women with breast cancer. With an authoring system under development to ensure extensibility, TEACH allows users to role-play in clinical oncology settings with virtual characters who interact on the basis of different combinations of African American sub-cultural beliefs regarding breast cancer. The paper reports on the roll-out and evaluation of the degree to which these interactions allow providers to acquire, practice, and refine culturally appropriate communication skills and to

  17. High sensitivity optically pumped quantum magnetometer.

    PubMed

    Tiporlini, Valentina; Alameh, Kamal

    2013-01-01

    Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz. PMID:23766716

  18. High Sensitivity Optically Pumped Quantum Magnetometer

    PubMed Central

    Tiporlini, Valentina; Alameh, Kamal

    2013-01-01

    Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz1/2 over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz1/2 in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz. PMID:23766716

  19. High sensitivity optically pumped quantum magnetometer.

    PubMed

    Tiporlini, Valentina; Alameh, Kamal

    2013-01-01

    Quantum magnetometers based on optical pumping can achieve sensitivity as high as what SQUID-based devices can attain. In this paper, we discuss the principle of operation and the optimal design of an optically pumped quantum magnetometer. The ultimate intrinsic sensitivity is calculated showing that optimal performance of the magnetometer is attained with an optical pump power of 20 μW and an operation temperature of 48°C. Results show that the ultimate intrinsic sensitivity of the quantum magnetometer that can be achieved is 327 fT/Hz(½) over a bandwidth of 26 Hz and that this sensitivity drops to 130 pT/Hz(½) in the presence of environmental noise. The quantum magnetometer is shown to be capable of detecting a sinusoidal magnetic field of amplitude as low as 15 pT oscillating at 25 Hz.

  20. High Stakes Testing and Student Achievement.

    ERIC Educational Resources Information Center

    Ediger, Marlow

    The effects of high stakes testing may be critical in the lives of public school students and may have many consequences for schools and teachers. There are no easy answers in measuring student achievement and in holding teachers accountable for learner progress. High stakes testing also involves responsibilities on the part of the principal who…

  1. Student Perceptions of High-Achieving Classmates

    ERIC Educational Resources Information Center

    Händel, Marion; Vialle, Wilma; Ziegler, Albert

    2013-01-01

    The reported study investigated students' perceptions of their high-performing classmates in terms of intelligence, social skills, and conscientiousness in different school subjects. The school subjects for study were examined with regard to cognitive, physical, and gender-specific issues. The results show that high academic achievements in…

  2. Nano-textured high sensitivity ion sensitive field effect transistors

    NASA Astrophysics Data System (ADS)

    Hajmirzaheydarali, M.; Sadeghipari, M.; Akbari, M.; Shahsafi, A.; Mohajerzadeh, S.

    2016-02-01

    Nano-textured gate engineered ion sensitive field effect transistors (ISFETs), suitable for high sensitivity pH sensors, have been realized. Utilizing a mask-less deep reactive ion etching results in ultra-fine poly-Si features on the gate of ISFET devices where spacing of the order of 10 nm and less is achieved. Incorporation of these nano-sized features on the gate is responsible for high sensitivities up to 400 mV/pH in contrast to conventional planar structures. The fabrication process for this transistor is inexpensive, and it is fully compatible with standard complementary metal oxide semiconductor fabrication procedure. A theoretical modeling has also been presented to predict the extension of the diffuse layer into the electrolyte solution for highly featured structures and to correlate this extension with the high sensitivity of the device. The observed ultra-fine features by means of scanning electron microscopy and transmission electron microscopy tools corroborate the theoretical prediction.

  3. High Achievers: 23rd Annual Survey. Attitudes and Opinions from the Nation's High Achieving Teens.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Northbrook, IL.

    This report presents data from an annual survey of high school student leaders and high achievers. It is noted that of the nearly 700,000 high achievers featured in this edition, 5,000 students were sent the survey and 2,092 questionnaires were completed. Subjects were high school juniors and seniors selected for recognition by their principals or…

  4. Achieving High Performance Perovskite Solar Cells

    NASA Astrophysics Data System (ADS)

    Yang, Yang

    2015-03-01

    Recently, metal halide perovskite based solar cell with the characteristics of rather low raw materials cost, great potential for simple process and scalable production, and extreme high power conversion efficiency (PCE), have been highlighted as one of the most competitive technologies for next generation thin film photovoltaic (PV). In UCLA, we have realized an efficient pathway to achieve high performance pervoskite solar cells, where the findings are beneficial to this unique materials/devices system. Our recent progress lies in perovskite film formation, defect passivation, transport materials design, interface engineering with respect to high performance solar cell, as well as the exploration of its applications beyond photovoltaics. These achievements include: 1) development of vapor assisted solution process (VASP) and moisture assisted solution process, which produces perovskite film with improved conformity, high crystallinity, reduced recombination rate, and the resulting high performance; 2) examination of the defects property of perovskite materials, and demonstration of a self-induced passivation approach to reduce carrier recombination; 3) interface engineering based on design of the carrier transport materials and the electrodes, in combination with high quality perovskite film, which delivers 15 ~ 20% PCEs; 4) a novel integration of bulk heterojunction to perovskite solar cell to achieve better light harvest; 5) fabrication of inverted solar cell device with high efficiency and flexibility and 6) exploration the application of perovskite materials to photodetector. Further development in film, device architecture, and interfaces will lead to continuous improved perovskite solar cells and other organic-inorganic hybrid optoelectronics.

  5. Reliability achievement in high technology space systems

    NASA Technical Reports Server (NTRS)

    Lindstrom, D. L.

    1981-01-01

    The production of failure-free hardware is discussed. The elements required to achieve such hardware are: technical expertise to design, analyze, and fully understand the design; use of high reliability parts and materials control in the manufacturing process; and testing to understand the system and weed out defects. The durability of the Hughes family of satellites is highlighted.

  6. Early predictors of high school mathematics achievement.

    PubMed

    Siegler, Robert S; Duncan, Greg J; Davis-Kean, Pamela E; Duckworth, Kathryn; Claessens, Amy; Engel, Mimi; Susperreguy, Maria Ines; Chen, Meichu

    2012-07-01

    Identifying the types of mathematics content knowledge that are most predictive of students' long-term learning is essential for improving both theories of mathematical development and mathematics education. To identify these types of knowledge, we examined long-term predictors of high school students' knowledge of algebra and overall mathematics achievement. Analyses of large, nationally representative, longitudinal data sets from the United States and the United Kingdom revealed that elementary school students' knowledge of fractions and of division uniquely predicts those students' knowledge of algebra and overall mathematics achievement in high school, 5 or 6 years later, even after statistically controlling for other types of mathematical knowledge, general intellectual ability, working memory, and family income and education. Implications of these findings for understanding and improving mathematics learning are discussed.

  7. Fiber specklegram sensors sensitivities at high temperatures

    NASA Astrophysics Data System (ADS)

    Rodriguez-Cobo, L.; Lomer, M.; Lopez-Higuera, J. M.

    2015-09-01

    In this work, the sensitivity of Fiber Specklegram Sensors to high temperatures (up to 800ºC) have been studied. Two multimode silica fibers have been introduced into a tubular furnace while a HeNe laser source was launched into a fiber edge, projecting speckle patterns to a commercial webcam. A computer generated different heating and cooling sweeps while the specklegram evolution was recorded. The achieved results exhibit a remarkably linearity in FSS's sensitivity for temperatures under 800ºC, following the thermal expansion of fused silica.

  8. Relations between shyness-sensitivity and internalizing problems in Chinese children: moderating effects of academic achievement.

    PubMed

    Chen, Xinyin; Yang, Fan; Wang, Li

    2013-07-01

    Shy-sensitive children are likely to develop adjustment problems in today's urban China as the country has evolved into an increasingly competitive, market-oriented society. The main purpose of this one-year longitudinal study was to examine the moderating effects of academic achievement on relations between shyness-sensitivity and later internalizing problems in Chinese children. A sample of 1171 school-age children (591 boys, 580 girls) in China, initially at the age of 9 years, participated in the study. Data on shyness, academic achievement, and internalizing problems were collected from multiple sources including peer evaluations, teacher ratings, self-reports, and school records. It was found that shyness positively and uniquely predicted later loneliness, depression, and teacher-rated internalizing problems, with the stability effect controlled, for low-achieving children, but not for high-achieving children. The results indicate that, consistent with the stress buffering model, academic achievement may be a buffering factor that serves to protect shy-sensitive children from developing psychological problems. PMID:23318940

  9. Attitudes and Opinions from the Nation's High Achieving Teens. 18th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Educational Communications, Inc., Lake Forest, IL.

    This document contains factsheets and news releases which cite findings from a national survey of 1,985 high achieving high school students. Factsheets describe the Who's Who Among American High School Students recognition and service program for high school students and explain the Who's Who survey. A summary report of this eighteenth annual…

  10. Dye-sensitized solar cells with 13% efficiency achieved through the molecular engineering of porphyrin sensitizers.

    PubMed

    Mathew, Simon; Yella, Aswani; Gao, Peng; Humphry-Baker, Robin; Curchod, Basile F E; Ashari-Astani, Negar; Tavernelli, Ivano; Rothlisberger, Ursula; Nazeeruddin, Md Khaja; Grätzel, Michael

    2014-03-01

    Dye-sensitized solar cells have gained widespread attention in recent years because of their low production costs, ease of fabrication and tunable optical properties, such as colour and transparency. Here, we report a molecularly engineered porphyrin dye, coded SM315, which features the prototypical structure of a donor-π-bridge-acceptor and both maximizes electrolyte compatibility and improves light-harvesting properties. Linear-response, time-dependent density functional theory was used to investigate the perturbations in the electronic structure that lead to improved light harvesting. Using SM315 with the cobalt(II/III) redox shuttle resulted in dye-sensitized solar cells that exhibit a high open-circuit voltage VOC of 0.91 V, short-circuit current density JSC of 18.1 mA cm(-2), fill factor of 0.78 and a power conversion efficiency of 13%.

  11. Dye-sensitized solar cells with 13% efficiency achieved through the molecular engineering of porphyrin sensitizers

    NASA Astrophysics Data System (ADS)

    Mathew, Simon; Yella, Aswani; Gao, Peng; Humphry-Baker, Robin; Curchod, Basile F. E.; Ashari-Astani, Negar; Tavernelli, Ivano; Rothlisberger, Ursula; Nazeeruddin, Md. Khaja; Grätzel, Michael

    2014-03-01

    Dye-sensitized solar cells have gained widespread attention in recent years because of their low production costs, ease of fabrication and tunable optical properties, such as colour and transparency. Here, we report a molecularly engineered porphyrin dye, coded SM315, which features the prototypical structure of a donor-π-bridge-acceptor and both maximizes electrolyte compatibility and improves light-harvesting properties. Linear-response, time-dependent density functional theory was used to investigate the perturbations in the electronic structure that lead to improved light harvesting. Using SM315 with the cobalt(II/III) redox shuttle resulted in dye-sensitized solar cells that exhibit a high open-circuit voltage VOC of 0.91 V, short-circuit current density JSC of 18.1 mA cm-2, fill factor of 0.78 and a power conversion efficiency of 13%.

  12. 21st Annual Survey of High Achievers: Attitudes and Opinions from the Nation's High Achieving Teens.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This survey was conducted by Who's Who Among American High School Students during the spring of 1990, to determine the attitudes of student leaders in U.S. high schools. A survey of high achievers sent to 5,000 students was completed and returned by approximately 2,000 students. All students were members of the junior or senior class during the…

  13. 22nd Annual Survey of High Achievers: Attitudes and Opinions from the Nation's High Achieving Teens.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Northbrook, IL.

    This study surveyed high school students (N=1,879) who were student leaders or high achievers in the spring of 1991 for the purpose of determining their attitudes. Students were members of the junior or senior high school class during the 1990-91 academic year and were selected for recognition by their principals or guidance counselors, other…

  14. Attitudes and Opinions from the Nation's High Achieving Teens: 26th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    A national survey of 3,351 high achieving high school students (junior and senior level) was conducted. All students had A or B averages. Topics covered include lifestyles, political beliefs, violence and entertainment, education, cheating, school violence, sexual violence and date rape, peer pressure, popularity, suicide, drugs and alcohol,…

  15. Attitudes and Opinions from the Nation's High Achieving Teens. 24th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This survey represents information compiled by the largest national survey of adolescent leaders and high achievers. Of the 5,000 students selected demographically from "Who's Who Among American High School Students," 1,957 responded. All students surveyed had "A" or "B" averages, and 98% planned on attending college. Questions were asked about…

  16. High-Sensitivity GaN Microchemical Sensors

    NASA Technical Reports Server (NTRS)

    Son, Kyung-ah; Yang, Baohua; Liao, Anna; Moon, Jeongsun; Prokopuk, Nicholas

    2009-01-01

    Systematic studies have been performed on the sensitivity of GaN HEMT (high electron mobility transistor) sensors using various gate electrode designs and operational parameters. The results here show that a higher sensitivity can be achieved with a larger W/L ratio (W = gate width, L = gate length) at a given D (D = source-drain distance), and multi-finger gate electrodes offer a higher sensitivity than a one-finger gate electrode. In terms of operating conditions, sensor sensitivity is strongly dependent on transconductance of the sensor. The highest sensitivity can be achieved at the gate voltage where the slope of the transconductance curve is the largest. This work provides critical information about how the gate electrode of a GaN HEMT, which has been identified as the most sensitive among GaN microsensors, needs to be designed, and what operation parameters should be used for high sensitivity detection.

  17. High Involvement Mothers of High Achieving Children: Potential Theoretical Explanations

    ERIC Educational Resources Information Center

    Hunsaker, Scott L.

    2013-01-01

    In American society, parents who have high aspirations for the achievements of their children are often viewed by others in a negative light. Various pejoratives such as "pushy parent," "helicopter parent," "stage mother," and "soccer mom" are used in the common vernacular to describe these parents. Multiple…

  18. High Ability Readers and the Achievement Gap

    ERIC Educational Resources Information Center

    Hunsaker, Scott L.; Parke, Cynthia J.; Bramble, Joan G.

    2004-01-01

    To close the achievement gap, the "No Child Left Behind" law calls for all students to make appropriate yearly progress. This presumably means that progress is being made by capable readers at the same time progress is being made by struggling readers. However, there appear to be unintended effects of "No Child Left Behind" that may impede the…

  19. Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina

    NASA Astrophysics Data System (ADS)

    An, Lin; Shen, Tueng T.; Wang, Ruikang K.

    2011-10-01

    This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of the human eye and head compared to the traditional OMAG system. To mitigate these motion artifacts on final imaging results, we propose a new phase compensation algorithm in which the traditional phase-compensation algorithm is repeatedly used to efficiently minimize the motion artifacts. Comparatively, this new algorithm demonstrates at least 8 to 25 times higher motion tolerability, critical for the UHS-OMAG system to achieve retinal microvasculature images with high quality. Furthermore, the new UHS-OMAG system employs a high speed line scan CMOS camera (240 kHz A-line scan rate) to capture 500 A-lines for one B-frame at a 400 Hz frame rate. With this system, we performed a series of in vivo experiments to visualize the retinal microvasculature in humans. Two featured imaging protocols are utilized. The first is of the low lateral resolution (16 μm) and a wide field of view (4 × 3 mm2 with single scan and 7 × 8 mm2 for multiple scans), while the second is of the high lateral resolution (5 μm) and a narrow field of view (1.5 × 1.2 mm2 with single scan). The great imaging performance delivered by our system suggests that UHS-OMAG can be a promising noninvasive alternative to the current clinical retinal microvasculature imaging techniques for the diagnosis of eye diseases with significant vascular involvement, such as diabetic retinopathy and age-related macular degeneration.

  20. High speed curved position sensitive detector

    DOEpatents

    Hendricks, Robert W.; Wilson, Jack W.

    1989-01-01

    A high speed curved position sensitive porportional counter detector for use in x-ray diffraction, the detection of 5-20 keV photons and the like. The detector employs a planar anode assembly of a plurality of parallel metallic wires. This anode assembly is supported between two cathode planes, with at least one of these cathode planes having a serpentine resistive path in the form of a meander having legs generally perpendicular to the anode wires. This meander is produced by special microelectronic fabrication techniques whereby the meander "wire" fans outwardly at the cathode ends to produce the curved aspect of the detector, and the legs of the meander are small in cross-section and very closely spaced whereby a spatial resolution of about 50 .mu.m can be achieved. All of the other performance characteristics are about as good or better than conventional position sensitive proportional counter type detectors. Count rates of up to 40,000 counts per second with 0.5 .mu.s shaping time constants are achieved.

  1. High-Achieving Students in the Era of NCLB

    ERIC Educational Resources Information Center

    Loveless, Tom; Parkas, Steve; Duffett, Ann

    2008-01-01

    This report contains two separate studies examining the status of high-achieving students in the No Child Left Behind (NCLB) era. Part I, An Analysis of NAEP Data, authored by Brookings Institution scholar Tom Loveless, examines achievement trends for high-achieving students (defined, like low-achieving students, by their performance on the…

  2. Improving Student Achievement: A Study of High-Poverty Schools with Higher Student Achievement Outcomes

    ERIC Educational Resources Information Center

    Butz, Stephen D.

    2012-01-01

    This research examined the education system at high-poverty schools that had significantly higher student achievement levels as compared to similar schools with lower student achievement levels. A multischool qualitative case study was conducted of the educational systems where there was a significant difference in the scores achieved on the…

  3. High School Employment and Youths' Academic Achievement

    ERIC Educational Resources Information Center

    Rothstein, Donna S.

    2007-01-01

    This paper asks whether employment during high school impacts youths' grade point average. Unlike much of the prior literature, it allows for the endogeneity of the hours and dropout decisions, uses ASVAB test scores, and tests whether youth employment is dynamic. The results indicate that high school employment and its lag have small, negative…

  4. Highly sensitive immunosensor using a nanofluidic preconcentrator.

    PubMed

    Liao, Ke-Pan; Sung, Kung-Bin

    2008-01-01

    This paper presents a micro-/nanofluidic biochip for enhanced sensitivity of immunoassay. By using a protein preconcentrator based on nanofluidic filters, we greatly improve the binding kinetics of immunoassay. A shallow nanofluidic channel connecting two microchannels for ion-selective filter is etched on the glass surface and sealed by PDMS/Glass irreversible bonding treated with O2 plasma. Our device achieved a 10(5) fold increase in protein concentration with 12 minutes of preconcentration. For applying the preconcentrator to immunoassay, we fabricated a novel device with a thin layer of Au sputtered near the nanochannel to provide a substrate for antibody immobilization and a sensing area at the site of highly concentrated proteins. After increasing the concentration of antibody and target antigen by multiple sample preconcentration steps, the binding kinetics of immunoassay can be significantly improved.

  5. Achieving strategic surety for high consequence software

    SciTech Connect

    Pollock, G.M.

    1996-09-01

    A strategic surety roadmap for high consequence software systems under the High Integrity Software (HIS) Program at Sandia National Laboratories guides research in identifying methodologies to improve software surety. Selected research tracks within this roadmap are identified and described detailing current technology and outlining advancements to be pursued over the coming decade to reach HIS goals. The tracks discussed herein focus on Correctness by Design, and System Immunology{trademark}. Specific projects are discussed with greater detail given on projects involving Correct Specification via Visualization, Synthesis, & Analysis; Visualization of Abstract Objects; and Correct Implementation of Components.

  6. Early Predictors of High School Mathematics Achievement

    ERIC Educational Resources Information Center

    Siegler, Robert S.; Duncan, Greg J.; Davis-Kean, Pamela E.; Duckworth, Kathryn; Claessens, Amy; Engel, Mimi; Susperreguy, Maria Ines; Meichu, Chen

    2012-01-01

    Identifying the types of mathematics content knowledge that are most predictive of students' long-term learning is essential for improving both theories of mathematical development and mathematics education. To identify these types of knowledge, we examined long-term predictors of high school students' knowledge of algebra and overall mathematics…

  7. Norview High School: Leadership Fosters Achievment

    ERIC Educational Resources Information Center

    Principal Leadership, 2013

    2013-01-01

    Often little unsaid things demonstrate what is truly important in a school. When teachers have common planning time and all of the department chairs share a single space as they do at Norview High School in Norfolk, VA, the unmistakable message is that instructional collaboration and leadership are expected and valued. Norview, an urban,…

  8. Achieving High-Temperature Ferromagnetic Topological Insulator

    NASA Astrophysics Data System (ADS)

    Katmis, Ferhat

    Topological insulators (TIs) are insulating materials that display conducting surface states protected by time-reversal symmetry, wherein electron spins are locked to their momentum. This unique property opens new opportunities for creating next-generation electronic and spintronic devices, including TI-based quantum computation. Introducing ferromagnetic order into a TI system without compromising its distinctive quantum coherent features could lead to a realization of several predicted novel physical phenomena. In particular, achieving robust long-range magnetic order at the TI surface at specific locations without introducing spin scattering centers could open up new possibilities for devices. Here, we demonstrate topologically enhanced interface magnetism by coupling a ferromagnetic insulator (FMI) to a TI (Bi2Se3); this interfacial ferromagnetism persists up to room temperature, even though the FMI (EuS) is known to order ferromagnetically only at low temperatures (<17 K). The induced magnetism at the interface resulting from the large spin-orbit interaction and spin-momentum locking feature of the TI surface is found to greatly enhance the magnetic ordering (Curie) temperature of the TI/FMI bilayer system. Due to the short range nature of the ferromagnetic exchange interaction, the time-reversal symmetry is broken only near the surface of a TI, while leaving its bulk states unaffected. The topological magneto-electric response originating in such an engineered TI could allow for an efficient manipulation of the magnetization dynamics by an electric field, providing an energy efficient topological control mechanism for future spin-based technologies. Work supported by MIT MRSEC through the MRSEC Program of NSF under award number DMR-0819762, NSF Grant DMR-1207469, the ONR Grant N00014-13-1-0301, and the STC Center for Integrated Quantum Materials under NSF grant DMR-1231319.

  9. Fast, high sensitivity dewpoint hygrometer

    NASA Technical Reports Server (NTRS)

    Hoenk, Michael E. (Inventor)

    1998-01-01

    A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

  10. Self-Concept and Achievement Motivation of High School Students

    ERIC Educational Resources Information Center

    Lawrence, A. S. Arul; Vimala, A.

    2013-01-01

    The present study "Self-concept and Achievement Motivation of High School Students" was investigated to find the relationship between Self-concept and Achievement Motivation of High School Students. Data for the study were collected using Self-concept Questionnaire developed by Raj Kumar Saraswath (1984) and Achievement Motive Test (ACMT)…

  11. Modified surface loading process for achieving improved performance of the quantum dot-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Liu, Feng; Jin, Zhongxiu; Zhu, Jun; Xu, Yafeng; Zhou, Li; Dai, Songyuan

    2016-06-01

    Achieving high surface coverage of the colloidal quantum dots (QDs) on TiO2 films has been challenging for quantum dot-sensitized solar cells (QDSCs). Herein, a general surface engineering approach was proposed to increase the loading of these QDs. It was found that S2- treatment/QD re-uptake process can significantly improve the attachment of the QDs on TiO2 films. Surface concentration of the QDs was improved by ∼60%, which in turn greatly enhances light absorption and decreases carrier recombination in QDSCs. Ensuing QDSCs with optimized QD loading exhibit a power conversion efficiency of 3.66%, 83% higher than those fabricated with standard procedures.

  12. High sensitivity ancilla assisted nanoscale DC magnetometry

    NASA Astrophysics Data System (ADS)

    Liu, Yixiang; Ajoy, Ashok; Marseglia, Luca; Saha, Kasturi; Cappellaro, Paola

    2016-05-01

    Sensing slowly varying magnetic fields are particularly relevant to many real world scenarios, where the signals of interest are DC or close to static. Nitrogen Vacancy (NV) centers in diamond are a versatile platform for such DC magnetometry on nanometer length scales. Using NV centers, the standard technique for measuring DC magnetic fields is via the Ramsey protocol, where sensitivities can approach better than 1 μ T/vHz, but are limited by the sensor fast dephasing time T2*. In this work we instead present a method of sensing DC magnetic fields that is intrinsically limited by the much longer T2 coherence time. The method exploits a strongly-coupled ancillary nuclear spin to achieve high DC field sensitivities potentially exceeding that of the Ramsey method. In addition, through this method we sense the perpendicular component of the DC magnetic field, which in conjunction with the parallel component sensed by the Ramsey method provides a valuable tool for vector DC magnetometry at the nanoscale.

  13. Cryogenic High-Sensitivity Magnetometer

    NASA Technical Reports Server (NTRS)

    Day, Peter; Chui, Talso; Goodstein, David

    2005-01-01

    A proposed magnetometer for use in a cryogenic environment would be sensitive enough to measure a magnetic-flux density as small as a picogauss (10(exp -16) Tesla). In contrast, a typical conventional flux-gate magnetometer cannot measure a magnetic-flux density smaller that about 1 microgauss (10(exp -10) Tesla). One version of this device, for operation near the low end of the cryogenic temperature range, would include a piece of a paramagnetic material on a platform, the temperature of which would be controlled with a periodic variation. The variation in temperature would be measured by use of a conventional germanium resistance thermometer. A superconducting coil would be wound around the paramagnetic material and coupled to a superconducting quantum interference device (SQUID) magnetometer.

  14. Sensitivity to general and specific numerical features in typical achievers and children with mathematics learning disability.

    PubMed

    Rotem, Avital; Henik, Avishai

    2015-01-01

    We examined the development of sensitivity to general and specific numerical features in typical achievers and in 6th and 8th graders with mathematics learning disability (MLD), using two effects in mental multiplication: operand-relatedness (i.e., difficulty in avoiding errors that are related to the operands via a shared multiplication row) and decade-consistency (i.e., difficulty in avoiding errors that are operand related and also share a decade with the true result). Responses to decade-consistent products were quick but erroneous. In line with the processing sequence in adults, children first became sensitive to the general numerical feature of operand-relatedness (typical achievers--from 3rd grade; children with MLD in 8th grade) and only later to the specific feature of decade-consistency (typical achievers--from 4th grade, but only from 6th grade in a mature pattern). Implications of the numerical sensitivity in children with MLD are discussed.

  15. Scientific Temper among Academically High and Low Achieving Adolescent Girls

    ERIC Educational Resources Information Center

    Kour, Sunmeet

    2015-01-01

    The present study was undertaken to compare the scientific temper of high and low achieving adolescent girl students. Random sampling technique was used to draw the sample from various high schools of District Srinagar. The sample for the present study consisted of 120 school going adolescent girls (60 high and 60 low achievers). Data was…

  16. Response to Marie Paz Morales' "Influence of Culture and Language Sensitive Physics on Science Attitude Achievement"

    ERIC Educational Resources Information Center

    Cole, Mikel Walker

    2015-01-01

    This response to Marie Paz Morales' "Influence of culture and language sensitive physics on science attitude achievement" explores the ideas of culturally responsive pedagogy and critical literacy to examine some implications for culturally responsive science instruction implicit in the original manuscript. [For "Influence of…

  17. Cross-National Estimates of the Effects of Family Background on Student Achievement: A Sensitivity Analysis

    ERIC Educational Resources Information Center

    Nonoyama-Tarumi, Yuko

    2008-01-01

    This article uses the data from the Programme for International Student Assessment (PISA) 2000 to examine whether the influence of family background on educational achievement is sensitive to different measures of the family's socio-economic status (SES). The study finds that, when a multidimensional measure of SES is used, the family background…

  18. Does Sensitivity to Criticism Mediate the Relationship between Theory of Mind and Academic Achievement?

    ERIC Educational Resources Information Center

    Lecce, Serena; Caputi, Marcella; Hughes, Claire

    2011-01-01

    This study adds to the growing research on school outcomes associated with individual differences in preschoolers' theory of mind skills by considering whether "costs" of theory of mind (e.g., sensitivity to criticism) actually help to foster children's academic achievement. A group of 60 Italian children was tested during the last year of…

  19. The Development of Product Parity Sensitivity in Children with Mathematics Learning Disability and in Typical Achievers

    ERIC Educational Resources Information Center

    Rotem, Avital; Henik, Avishai

    2013-01-01

    Parity helps us determine whether an arithmetic equation is true or false. The current research examines the development of sensitivity to parity cues in multiplication in typically achieving (TA) children (grades 2, 3, 4 and 6) and in children with mathematics learning disabilities (MLD, grades 6 and 8), via a verification task. In TA children…

  20. Response to Marie Paz Morales' ``Influence of culture and language sensitive physics on science attitude achievement''

    NASA Astrophysics Data System (ADS)

    Cole, Mikel Walker

    2015-12-01

    This response to Marie Paz Morales' "Influence of culture and language sensitive physics on science attitude achievement" explores the ideas of culturally responsive pedagogy and critical literacy to examine some implications for culturally responsive science instruction implicit in the original manuscript.

  1. Perspectives of High-Achieving Women on Teaching

    ERIC Educational Resources Information Center

    Snodgrass, Helen

    2010-01-01

    High-achieving women are significantly less likely to enter the teaching profession than they were just 40 years ago. Why? While the social and economic reasons for this decline have been well documented in the literature, what is lacking is a discussion with high-achieving women, as they make their first career decisions, about their perceptions…

  2. High sensitivity cymbal-based accelerometer

    SciTech Connect

    Sun Chengliang; Lam, K.H.; Choy, S.H.; Chan, H.L. W.; Zhao, X.-Z.; Choy, C.L.

    2006-03-15

    A high sensitivity piezoelectric accelerometer has been developed by replacing the conventional piezoelectric rings with a cymbal transducer. The sensitivity of the cymbal-based accelerometers containing cymbal transducers with different endcap thicknesses and different seismic masses has been measured as a function of driving frequency. Due to the high d{sub 33}{sup '} coefficient of the cymbal transducers, the cymbal-based accelerometers have a high sensitivity of {approx}97 pC/ms{sup -2} with the amplitude rise of 2.85% (<1 dB) at one-third of the mounted resonance frequency (3.38 kHz). The effect of the seismic mass, the resonance frequency, and d{sub 33}{sup '} coefficient of the cymbal transducers on the sensitivity and the frequency range of the cymbal-based accelerometers are reported.

  3. Test-Taking Strategies of High and Low Mathematics Achievers

    ERIC Educational Resources Information Center

    Hong, Eunsook; Sas, Maggie; Sas, John C.

    2006-01-01

    The authors explored test-preparation and test-taking strategies that high school students used in algebra tests. From a pool of high school students (N = 156), 61 students participated in interviews, and of those interviewed, 26 represented those who were high achieving as well as highly interested in mathematics (n = 15) vs. those who were low…

  4. Effectiveness of High Schools in Australia: Holding Power and Achievement.

    ERIC Educational Resources Information Center

    Ainley, John; Sheret, Michael

    High schools in Australia are increasingly expected to be effective in holding students at school to year 12 as well as in promoting achievement. Analysis of quantitative data gathered as part of a longitudinal study of 22 New South Wales (Australia) schools shows that schools differ in their holding power as well as in the achievement levels of…

  5. Tracking and Detracking: High Achievers in Massachusetts Middle Schools

    ERIC Educational Resources Information Center

    Loveless, Tom

    2009-01-01

    This study examines tracking--the practice of grouping students into separate classes or courses based on their prior academic achievement--at the middle-school level, and the percentage of high-achieving students in tracked and untracked schools. It focuses on Massachusetts, a leader in "reforming" tracking, and the changes that have…

  6. Some Correlates of High School Foreign Language Achievement.

    ERIC Educational Resources Information Center

    Beanblossom, Gary F.

    This paper investigates the influences of traditional kinds of verbal and quantitative achievement and aptitude variables on high school foreign language achievement, as measured by Modern Language Association and University of Washington tests of language skills administered to entering college students. The report focuses on: (1) the sample and…

  7. Biculturalism and Academic Achievement of African American High School Students

    ERIC Educational Resources Information Center

    Rust, Jonathan P.; Jackson, Margo A.; Ponterotto, Joseph G.; Blumberg, Fran C.

    2011-01-01

    Biculturalism was examined as a factor that may positively affect the academic achievement of African American high school students, beyond cultural identity and self-esteem. Hierarchical regression analyses determined that cultural identity and academic self-esteem were important factors for academic achievement, but not biculturalism.…

  8. Mobility and Student Achievement in High Poverty Schools

    ERIC Educational Resources Information Center

    Dalton, Janet Denise

    2013-01-01

    Student mobility is an issue for high poverty schools in the shadow of increased rigor and accountability for student performance. Whereas mobility is not a sole cause for poor achievement, it is a contributing factor for students in poverty who are already considered to be at risk of low achievement. Student mobility creates a hardship for…

  9. High sensitivity knitted fabric strain sensors

    NASA Astrophysics Data System (ADS)

    Xie, Juan; Long, Hairu; Miao, Menghe

    2016-10-01

    Wearable sensors are increasingly used in smart garments for detecting and transferring vital signals and body posture, movement and respiration. Existing fabric strain sensors made from metallized yarns have low sensitivity, poor comfort and low durability to washing. Here we report a knitted fabric strain sensor made from a cotton/stainless steel (SS) fibre blended yarn which shows much higher sensitivity than sensors knitted from metallized yarns. The fabric feels softer than pure cotton textiles owing to the ultrafine stainless steel fibres and does not lose its electrical property after washing. The reason for the high sensitivity of the cotton/SS knitted fabric sensor was explored by comparing its sensing mechanism with the knitted fabric sensor made from metallized yarns. The results show that the cotton/SS yarn-to-yarn contact resistance is highly sensitive to strain applied to hooked yarn loops.

  10. Attitudes and Opinions from the Nation's High Achieving Teens: 29th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This report presents the 1998 statistical findings of the annual survey to determine the attitudes of national high school student leaders. Questionnaires were completed by 3,123 high school juniors and seniors, all of whom were selected for recognition in "Who's Who among American High School Students." In addition to demographic information, the…

  11. High Sensitivity deflection detection of nanowires

    SciTech Connect

    Sanii, Babak; Ashby, Paul

    2009-10-28

    A critical limitation of nanoelectromechanical systems (NEMS) is the lack of a high-sensitivity position detection mechanism. We introduce a noninterferometric optical approach to determine the position of nanowires with a high sensitivity and bandwidth. Its physical origins and limitations are determined by Mie scattering analysis. This enables a dramatic miniaturization of detectable cantilevers, with attendant reductions to the fundamental minimum force noise in highly damping environments. We measure the force noise of an 81{+-}9??nm radius Ag{sub 2}Ga nanowire cantilever in water at 6{+-}3??fN/{radical}Hz.

  12. The "Renaissance Child": High Achievement and Gender in Late Modernity

    ERIC Educational Resources Information Center

    Skelton, Christine; Francis, Becky

    2012-01-01

    This paper draws on the concept of the "Renaissance Child" to illustrate the ways in which gender influences the opportunities and possibilities of high-achieving pupils. Using data from a study of 12-13-year high-achieving boys and girls based in schools in England, the paper considers the ways in which a group of popular boys was able to show an…

  13. High sensitivity optical waveguide accelerometer based on Fano resonance.

    PubMed

    Wan, Fenghua; Qian, Guang; Li, Ruozhou; Tang, Jie; Zhang, Tong

    2016-08-20

    An optical waveguide accelerometer based on tunable asymmetrical Fano resonance in a ring-resonator-coupled Mach-Zehnder interferometer (MZI) is proposed and analyzed. A Fano resonance accelerometer has a relatively large workspace of coupling coefficients with high sensitivity, which has potential application in inertial navigation, missile guidance, and attitude control of satellites. Due to the interference between a high-Q resonance pathway and a coherent background pathway, a steep asymmetric line shape is generated, which greatly improves the sensitivity of this accelerometer. The sensitivity of the accelerometer is about 111.75 mW/g. A 393-fold increase in sensitivity is achieved compared with a conventional MZI accelerometer and is approximately equal to the single ring structure.

  14. High sensitivity optical waveguide accelerometer based on Fano resonance.

    PubMed

    Wan, Fenghua; Qian, Guang; Li, Ruozhou; Tang, Jie; Zhang, Tong

    2016-08-20

    An optical waveguide accelerometer based on tunable asymmetrical Fano resonance in a ring-resonator-coupled Mach-Zehnder interferometer (MZI) is proposed and analyzed. A Fano resonance accelerometer has a relatively large workspace of coupling coefficients with high sensitivity, which has potential application in inertial navigation, missile guidance, and attitude control of satellites. Due to the interference between a high-Q resonance pathway and a coherent background pathway, a steep asymmetric line shape is generated, which greatly improves the sensitivity of this accelerometer. The sensitivity of the accelerometer is about 111.75 mW/g. A 393-fold increase in sensitivity is achieved compared with a conventional MZI accelerometer and is approximately equal to the single ring structure. PMID:27556984

  15. A sensitive and high dynamic range cw laser power meter

    NASA Astrophysics Data System (ADS)

    Krishnan, S.; Bindra, K. S.; Oak, S. M.

    2008-12-01

    We report the design of a cost effective, highly sensitive cw laser power meter with a large dynamic range based on a photodiode. The power meter consists of a photodiode, a current to voltage converter circuit, an offset balancing circuit, a microcontroller, an analog to digital converter, reed relays, and an alphanumeric liquid crystal display. The power meter can record absolute laser power levels as low as 1 pW. The dynamic range measured with a cw laser at a wavelength of 532 nm is 8×1010. The high sensitivity and large dynamic range are achieved by the implementation of an analog background balancing circuit and autoranging.

  16. Attitudes and Opinions from the Nation's High Achieving Teens: 27th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This report details the 27th annual study to examine the attitudes of student leaders in U.S. high schools. Participating in the survey were 3,370 adolescents, primarily 16- and 17-year-olds, who had been featured in the 1996 edition of "Who's Who Among American High School Students." The report presents demographic information on the survey…

  17. Attitudes and Opinions from the Nation's High Achieving Teens: 28th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This report details the 28th annual study to examine the attitudes of student leaders in U.S. high schools. Participating in the survey were 3,210 adolescents, primarily 16- and 17-year-olds, who had been featured in the 1997 edition of "Who's Who Among American High School Students." The report presents demographic information on the survey…

  18. Social class and academic achievement in college: the interplay of rejection sensitivity and entity beliefs.

    PubMed

    Rheinschmidt, Michelle L; Mendoza-Denton, Rodolfo

    2014-07-01

    Undergraduates, especially those from lower income backgrounds, may perceive their social class background as different or disadvantaged relative to that of peers and worry about negative social treatment. We hypothesized that concerns about discrimination based on one's social class (i.e., class-based rejection sensitivity or RS-class) would be damaging to undergraduates' achievement outcomes particularly among entity theorists, who perceive their personal characteristics as fixed. We reasoned that a perceived capacity for personal growth and change, characteristic of incremental theorists, would make the pursuit of a college degree and upward mobility seem more worthwhile and attainable. We found evidence across 3 studies that dispositionally held and experimentally primed entity (vs. incremental) beliefs predicted college academic performance as a function of RS-class. Studies 1a and 1b documented that high levels of both entity beliefs and RS-class predicted lower self-reported and official grades, respectively, among undergraduates from socioeconomically diverse backgrounds. In Study 2, high entity beliefs and RS-class at matriculation predicted decreased year-end official grades among lower class Latino students. Study 3 established the causal relationship of entity (vs. incremental) beliefs on academic test performance as a function of RS-class. We observed worse test performance with higher RS-class levels following an entity (vs. incremental) prime, an effect driven by lower income students. Findings from a 4th study suggest that entity theorists with RS-class concerns tend to believe less in upward mobility and, following academic setbacks, are prone to personal attributions of failure, as well as hopelessness. Implications for education and intervention are discussed.

  19. Successful kidney transplantation in highly sensitized patients.

    PubMed

    Zhang, Weijie; Chen, Dong; Chen, Zhishui; Zeng, Fanjun; Ming, Changsheng; Lin, Zhengbin; Zhou, Ping; Chen, Gang; Chen, Xiaoping

    2011-03-01

    Highly sensitized patients experience an increased number of rejection episodes and have poorer graft survival rates; hence, sensitization is a significant barrier to both access to and the success of organ transplantation. This study reports our experience in kidney transplantation in highly sensitized patients. Fourteen patients with sensitization or high levels of panelreactive antibodies (PRA) were studied. All patients were desensitized with pre-transplant intravenous immunoglobulin (IVIG)/plasmapheresis (PP) with or without rituximab and thymoglobulin induction therapy, combined with a Prograf/MMF/Pred immunosuppressive regimen. Of 14 patients, 10 showed good graft functions without acute rejection (AR) episodes. Acute cellular rejection in two patients was reversed by methylprednisolone. Two patients underwent antibody-mediated rejection; one was treated with PP/IVIG successfully, whereas the other lost graft functions due to the de novo production of donor-specific antibodies (DSA). Graft functions were stable, and there were no AR episodes in other patients. Conclusively, desensitization using PP/IVIG with or without rituximab increases the likelihood of successful live-donor kidney transplantation in sensitized recipients. PMID:21681679

  20. Attitudes and Opinions from the Nation's High Achieving Teens. 25th Annual Survey of High Achievers.

    ERIC Educational Resources Information Center

    Who's Who among American High School Students, Lake Forest, IL.

    This survey was conducted during the spring of 1994 for the purpose of determining the attitudes of student leaders in the nation's high schools. Eight thousand surveys were sent out to students, of which 3177 were returned. All students surveyed were members of the junior or senior class during the 1993-94 academic year. They were selected for…

  1. Student Achievement for Whom? High-Performing and Still "Playing the Game," the Meaning of School Achievement among High Achieving African American Students

    ERIC Educational Resources Information Center

    Wiggan, Greg

    2014-01-01

    The preponderance of the research on African American students has generally focused on issues of school failure and underperformance. While the literature on high achieving Black students is sparse, very little is known about these students' school experiences and the meanings that they assign to achievement. Using student-based inquiry…

  2. Environmental Sensitivity among Wisconsin High School Students.

    ERIC Educational Resources Information Center

    Sivek, Daniel J.

    2002-01-01

    A two-phase study was conducted to assess influences on environmental sensitivity (ES) in Wisconsin high school students. Three categories of influences emerged from phase I: environmental, role model, and personality. The influence most frequently cited by students as most important was time spent outdoors. Develops a profile of environmentally…

  3. High School Employment and Academic Achievement: A Note for Educators

    ERIC Educational Resources Information Center

    Keister, Mary; Hall, Joshua

    2010-01-01

    Educators are often in a position to affect student decisions to work during the school term. This study reviews and summarizes the literature on the effect that employment during high school has on academic achievement. The available evidence suggests that part-time jobs for high school students are beneficial as long as the number of hours…

  4. Exploring High-Achieving Students' Images of Mathematicians

    ERIC Educational Resources Information Center

    Aguilar, Mario Sánchez; Rosas, Alejandro; Zavaleta, Juan Gabriel Molina; Romo-Vázquez, Avenilde

    2016-01-01

    The aim of this study is to describe the images that a group of high-achieving Mexican students hold of mathematicians. For this investigation, we used a research method based on the Draw-A-Scientist Test (DAST) with a sample of 63 Mexican high school students. The group of students' pictorial and written descriptions of mathematicians assisted us…

  5. Brain Hemisphericity and Mathematics Achievement of High School Students

    ERIC Educational Resources Information Center

    Fernandez, Sanny F.

    2011-01-01

    This study aimed to find out the brain hemisphericity and mathematics achievement of high school students. The respondents of the study were the 168 first year high school students of Colegio de San Jose, during school year 2010-2011 who were chosen through stratified random sampling. The descriptive and interview methods of research were used in…

  6. High-sensitivity three-mode optomechanical transducer

    SciTech Connect

    Zhao, C.; Fang, Q.; Susmithan, S.; Miao, H.; Ju, L.; Fan, Y.; Blair, D.; Hosken, D. J.; Munch, J.; Veitch, P. J.; Slagmolen, B. J. J.

    2011-12-15

    Three-mode optomechanical interactions have been predicted to allow the creation of very high sensitivity transducers in which very strong optical self-cooling and strong optomechanical quantum entanglement are predicted. Strong coupling is achieved by engineering a transducer in which both the pump laser and a single signal sideband frequency are resonantly enhanced. Here we demonstrate that very high sensitivity can be achieved in a very simple system consisting of a Fabry-Perot cavity with CO{sub 2} laser thermal tuning. We demonstrate a displacement sensitivity of {approx}1x10{sup -17} m/{radical}(Hz), which is sufficient to observe a thermally excited acoustic mode in a 5.6 kg sapphire mirror with a signal-to-noise ratio of more than 20 dB. It is shown that a measurement sensitivity of {approx}2x10{sup -20} m/{radical}(Hz) limited by the quantum shot noise is achievable with optimization of the cavity parameters.

  7. Single photon detector with high polarization sensitivity

    PubMed Central

    Guo, Qi; Li, Hao; You, LiXing; Zhang, WeiJun; Zhang, Lu; Wang, Zhen; Xie, XiaoMing; Qi, Ming

    2015-01-01

    Polarization is one of the key parameters of light. Most optical detectors are intensity detectors that are insensitive to the polarization of light. A superconducting nanowire single photon detector (SNSPD) is naturally sensitive to polarization due to its nanowire structure. Previous studies focused on producing a polarization-insensitive SNSPD. In this study, by adjusting the width and pitch of the nanowire, we systematically investigate the preparation of an SNSPD with high polarization sensitivity. Subsequently, an SNSPD with a system detection efficiency of 12% and a polarization extinction ratio of 22 was successfully prepared. PMID:25875225

  8. An Analysis of High School Mathematics Achievement and English Language Arts Achievement as Predictors of Science Achievement

    ERIC Educational Resources Information Center

    Edwards, Anthony C.

    2012-01-01

    Science assessments require students to read and comprehend questions and to solve mathematical problems. The purpose of this study is to determine whether the following variables can be used to predict science achievement: English language arts achievement, mathematics achievement, socioeconomic status (SES), limited English proficiency (LEP)…

  9. High blood pressure and visual sensitivity

    NASA Astrophysics Data System (ADS)

    Eisner, Alvin; Samples, John R.

    2003-09-01

    The study had two main purposes: (1) to determine whether the foveal visual sensitivities of people treated for high blood pressure (vascular hypertension) differ from the sensitivities of people who have not been diagnosed with high blood pressure and (2) to understand how visual adaptation is related to standard measures of systemic cardiovascular function. Two groups of middle-aged subjects-hypertensive and normotensive-were examined with a series of test/background stimulus combinations. All subjects met rigorous inclusion criteria for excellent ocular health. Although the visual sensitivities of the two subject groups overlapped extensively, the age-related rate of sensitivity loss was, for some measures, greater for the hypertensive subjects, possibly because of adaptation differences between the two groups. Overall, the degree of steady-state sensitivity loss resulting from an increase of background illuminance (for 580-nm backgrounds) was slightly less for the hypertensive subjects. Among normotensive subjects, the ability of a bright (3.8-log-td), long-wavelength (640-nm) adapting background to selectively suppress the flicker response of long-wavelength-sensitive (LWS) cones was related inversely to the ratio of mean arterial blood pressure to heart rate. The degree of selective suppression was also related to heart rate alone, and there was evidence that short-term changes of cardiovascular response were important. The results suggest that (1) vascular hypertension, or possibly its treatment, subtly affects visual function even in the absence of eye disease and (2) changes in blood flow affect retinal light-adaptation processes involved in the selective suppression of the flicker response from LWS cones caused by bright, long-wavelength backgrounds.

  10. Highly Energetic, Low Sensitivity Aromatic Peroxy Acids.

    PubMed

    Gamage, Nipuni-Dhanesha H; Stiasny, Benedikt; Stierstorfer, Jörg; Martin, Philip D; Klapötke, Thomas M; Winter, Charles H

    2016-02-18

    The synthesis, structure, and energetic materials properties of a series of aromatic peroxy acid compounds are described. Benzene-1,3,5-tris(carboperoxoic) acid is a highly sensitive primary energetic material, with impact and friction sensitivities similar to those of triacetone triperoxide. By contrast, benzene-1,4-bis(carboperoxoic) acid, 4-nitrobenzoperoxoic acid, and 3,5-dinitrobenzoperoxoic acid are much less sensitive, with impact and friction sensitivities close to those of the secondary energetic material 2,4,6-trinitrotoluene. Additionally, the calculated detonation velocities of 3,5-dinitrobenzoperoxoic acid and 2,4,6-trinitrobenzoperoxoic acid exceed that of 2,4,6-trinitrotoluene. The solid-state structure of 3,5-dinitrobenzoperoxoic acid contains intermolecular O-H⋅⋅⋅O hydrogen bonds and numerous N⋅⋅⋅O, C⋅⋅⋅O, and O⋅⋅⋅O close contacts. These attractive lattice interactions may account for the less sensitive nature of 3,5-dinitrobenzoperoxoic acid. PMID:26743434

  11. Highly Energetic, Low Sensitivity Aromatic Peroxy Acids.

    PubMed

    Gamage, Nipuni-Dhanesha H; Stiasny, Benedikt; Stierstorfer, Jörg; Martin, Philip D; Klapötke, Thomas M; Winter, Charles H

    2016-02-18

    The synthesis, structure, and energetic materials properties of a series of aromatic peroxy acid compounds are described. Benzene-1,3,5-tris(carboperoxoic) acid is a highly sensitive primary energetic material, with impact and friction sensitivities similar to those of triacetone triperoxide. By contrast, benzene-1,4-bis(carboperoxoic) acid, 4-nitrobenzoperoxoic acid, and 3,5-dinitrobenzoperoxoic acid are much less sensitive, with impact and friction sensitivities close to those of the secondary energetic material 2,4,6-trinitrotoluene. Additionally, the calculated detonation velocities of 3,5-dinitrobenzoperoxoic acid and 2,4,6-trinitrobenzoperoxoic acid exceed that of 2,4,6-trinitrotoluene. The solid-state structure of 3,5-dinitrobenzoperoxoic acid contains intermolecular O-H⋅⋅⋅O hydrogen bonds and numerous N⋅⋅⋅O, C⋅⋅⋅O, and O⋅⋅⋅O close contacts. These attractive lattice interactions may account for the less sensitive nature of 3,5-dinitrobenzoperoxoic acid.

  12. Behind the High Achievement of East Asian Students.

    ERIC Educational Resources Information Center

    Leung, Frederick K. S.

    2002-01-01

    Studied reasons for the high achievement students from Hong Kong, Japan, South Korea, and Singapore on the Third International Mathematics and Science Study (TIMSS). Questionnaire data provided by students participating show that the superior results of these students may have come at the expense of other aspects of student development. Results…

  13. Progress Lags in High School, Especially for Advanced Achievers

    ERIC Educational Resources Information Center

    Education Digest: Essential Readings Condensed for Quick Review, 2012

    2012-01-01

    This report by the Center on Education Policy (CEP), an independent nonprofit organization, examines trends in the achievement of high school students on the state reading/English language arts (ELA) and mathematics tests used for accountability under the No Child Left Behind Act (NCLB). This study confirms that there is reason for concern about…

  14. Learning Environment, Motivation, and Achievement in High School Science.

    ERIC Educational Resources Information Center

    Nolen, Susan Bobbitt

    2003-01-01

    Examines the relationship between high school students' perceptions of their science learning environments and their motivation, learning strategies, and achievement. Discusses the focus of shared perceptions and instruction and indicates that shared perceptions focused on understanding and independent thinking positively predicted students'…

  15. High Achieving Girls in Mathematics: What's Wrong with Working Hard?

    ERIC Educational Resources Information Center

    Howe, Ann C.; Berenson, Sarah B.

    2003-01-01

    The participation of women in graduate studies and mathematics-related careers remains a social and economic problem in the United States. Part of a larger study to understand this lack of participation, here we present preliminary findings of girls who are high achievers in middle grades mathematics. This interpretive study documents girls'…

  16. Relationship between High School Leadership Team Practices and Student Achievement

    ERIC Educational Resources Information Center

    McInnis, Timothy M.

    2009-01-01

    This study investigated if a relationship existed between student achievement in 10th grade Missouri Assessment Program mathematics and 11th grade communication arts scores in 2007 and high school leadership team perceptions of the extent to which they demonstrated leadership practices. The secondary purpose was to compare perceptional…

  17. Improving Student Achievement in Today's High Schools: What Works.

    ERIC Educational Resources Information Center

    Shields, Marie S.

    This paper is based on a study of two high schools in Maine that achieved outstanding and consistent gains in English, math, and science over a 5-year period. Three strands of inquiry were used for the study: surveys, interviews, and observations. A multiple-perspective approach was used to integrate the information so as to evaluate the…

  18. Mercer Middle School Case Study: High Science and Math Achievement

    ERIC Educational Resources Information Center

    Washington State Board of Education, 2010

    2010-01-01

    To spotlight effective practices, the Washington State Board of Education (SBE) is highlighting schools that are closing achievement gaps and performing at high levels. In 2009, the SBE partnered with the Office of Superintendent of Public Instruction (OSPI) to create the Washington Accountability Index. The Index is a new way to measure schools'…

  19. Supplementary Education: The Hidden Curriculum of High Academic Achievement

    ERIC Educational Resources Information Center

    Gordon, Edmund W., Ed.; Bridglall, Beatrice L., Ed.; Meroe, Aundra Saa, Ed.

    2004-01-01

    In this book, the editors argue that while access to schools that enable and expect academic achievement is a necessary ingredient for the education of students, schools alone may not be sufficient to ensure universally high levels of academic development. Supplemental educational experiences may also be needed. The idea of supplementary education…

  20. Analysis of Three High-Achieving Young Adolescent Girls

    ERIC Educational Resources Information Center

    Lim, Jae Hoon; Chae, Jeong-Lim; Schinck-Mikel, Amelie G.; Watson, Jimmy

    2013-01-01

    This paper presents an in-depth cross-case analysis of three high-achieving young adolescent girls who had contrasting mathematics learning experiences during the first year of middle school. In particular, this study examines the foundation for their motivation, as well as the dominant mode of learning and academic engagement in relation to three…

  1. Test Score Decline Among High Achievers: Policy Implications.

    ERIC Educational Resources Information Center

    Goldman, Jerrold; Hsia, Jayjia

    Since 1967, the mean Scholastic Aptitude Test (SAT) score has declined. Likewise, the numbers of candidates receiving high SAT scores have been decreasing steadily. The same downward trend in student achievement can be seen among student groups from grade 4 through post graduate studies. In recent years, policy has been directed towards making…

  2. Student Achievement through the Development of Complete High School Culture

    ERIC Educational Resources Information Center

    Lamphere, Michael Frederick, Jr.

    2012-01-01

    This dissertation undertook an investigation of school culture and achievement in the high school setting. The national data set ELS:2002 was used as the pool of variables because it allows for a complete picture of school culture comprising students, parents, administrators, and teachers. The data were selected based on current literature and…

  3. The High Trust Classroom: Raising Achievement from the Inside Out

    ERIC Educational Resources Information Center

    Moore, Lonnie

    2009-01-01

    This book provides a roadmap to developing a high-trust classroom, a classroom: (1) With increased student achievement; (2) With few discipline problems; (3) Where students are intrinsically motivated; and (4) Where the teacher can confidently use creative lesson planning. The author presents a simple step by step approach to earning the trust of…

  4. Self-Esteem and Academic Achievement of High School Students

    ERIC Educational Resources Information Center

    Moradi Sheykhjan, Tohid; Jabari, Kamran; Rajeswari, K.

    2014-01-01

    The primary purpose of this study was to determine the influence of self-esteem on academic achievement among high school students in Miandoab City of Iran. The methodology of the research is descriptive and correlation that descriptive and inferential statistics were used to analyze the data. Statistical Society includes male and female high…

  5. [Clinical interpretation of high sensitivity troponin T].

    PubMed

    Alquézar Arbé, Aitor; Santaló Bel, Miguel; Sionis, Alessandro

    2015-09-21

    Determination of cardiac troponin (cTn) is necessary for the diagnosis of acute myocardial infarction without ST segment elevation. However Tnc can be released in other clinical situations. The development of high-sensitive cTn T assays (hs-cTnT) improves the management of patients with suspected acute coronary syndrome. Here, we provide an overview of the diverse causes of hs-cTnT elevation and recommend strategies for the clinical interpretation of the test result.

  6. Highly sensitive catalytic spectrophotometric determination of ruthenium

    NASA Astrophysics Data System (ADS)

    Naik, Radhey M.; Srivastava, Abhishek; Prasad, Surendra

    2008-01-01

    A new and highly sensitive catalytic kinetic method (CKM) for the determination of ruthenium(III) has been established based on its catalytic effect on the oxidation of L-phenylalanine ( L-Pheala) by KMnO 4 in highly alkaline medium. The reaction has been followed spectrophotometrically by measuring the decrease in the absorbance at 526 nm. The proposed CKM is based on the fixed time procedure under optimum reaction conditions. It relies on the linear relationship where the change in the absorbance (Δ At) versus added Ru(III) amounts in the range of 0.101-2.526 ng ml -1 is plotted. Under the optimum conditions, the sensitivity of the proposed method, i.e. the limit of detection corresponding to 5 min is 0.08 ng ml -1, and decreases with increased time of analysis. The method is featured with good accuracy and reproducibility for ruthenium(III) determination. The ruthenium(III) has also been determined in presence of several interfering and non-interfering cations, anions and polyaminocarboxylates. No foreign ions interfered in the determination ruthenium(III) up to 20-fold higher concentration of foreign ions. In addition to standard solutions analysis, this method was successfully applied for the quantitative determination of ruthenium(III) in drinking water samples. The method is highly sensitive, selective and very stable. A review of recently published catalytic spectrophotometric methods for the determination of ruthenium(III) has also been presented for comparison.

  7. High refractive index and temperature sensitivity LPGs for high temperature operation

    NASA Astrophysics Data System (ADS)

    Nascimento, I. M.; Gouveia, C.; Jana, Surnimal; Bera, Susanta; Baptista, J. M.; Moreira, Paulo; Biwas, Palas; Bandyopadhyay, Somnath; Jorge, Pedro A. S.

    2013-11-01

    A fiber optic sensor for high sensitivity refractive index and temperature measurement able to withstand temperature up to 450 °C is reported. Two identical LPG gratings were fabricated, whereas one was coated with a high refractive index (~1.78) sol-gel thin film in order to increase its sensitivity to the external refractive index. The two sensors were characterized and compared in refractive index and temperature. Sensitivities of 1063 nm/RIU (1.338 - 1.348) and 260 pm/°C were achieved for refractive index and temperature, respectively.

  8. High-sensitivity SQUIDs with dispersive readout for scanning microscopy

    NASA Astrophysics Data System (ADS)

    Mol, J. M.; Foroughi, F.; Arps, J.; Kammerloher, E.; Bethke, P.; Gibson, G. W., Jr.; Fung, Y. K. K.; Klopfer, B.; Nowack, K.; Kratz, P. A.; Huber, M. E.; Moler, K. A.; Kirtley, J. R.; Bluhm, H.

    2014-03-01

    In a scanning SQUID microscope, the high magnetic flux sensitivity is utilized to image magnetic properties of sample surfaces. As an alternative to the widely used DC SQUIDs, we present Nb SQUIDs for scanning with dispersive microwave readout, featuring significantly higher bandwidth and sensitivity. An on-chip shunt capacitor in parallel with the junction and flux pickup loops forms an LC resonator whose resonance depends on the flux in the SQUID. The readout utilizes a phase-sensitive detection of the reflected drive signal at the SQUID's resonance frequency. Highest sensitivities are achieved by making use of the inherent nonlinearity of the device at high excitation powers. We present a study of the characteristics and noise measurements of our sensors at 4 K. Extrapolations from our results to 300 mK indicate that flux sensitivities as low as 50 nΦ0Hz- 1 / 2 could be possible. Using high-resolution lithography, our sensors promise sub-micron spatial resolution. Integrated into a scanning microscope, they will provide a powerful tool for the study of weak magnetic effects and quantum coherent phenomena. This work was supported by NSF IMR-MIP grant No. 0957616 and the Alfried Krupp von Bohlen und Halbach - Foundation.

  9. Learning environment, motivation, and achievement in high school science

    NASA Astrophysics Data System (ADS)

    Bobbitt Nolen, Susan

    2003-04-01

    In a study of the relationship between high school students' perceptions of their science learning environments and their motivation, learning strategies, and achievement, 377 students in 22 introductory science classrooms completed surveys in the fall and spring of their ninth-grade year. Hierarchical linear regression was used to model the effects of variables at both the classroom and individual level simultaneously. High intraclass agreement (indicated by high parameter reliability) on all classroom environment measures indicated that students shared perceptions of the classroom learning environment. Controlling for other factors, shared perceptions that only the most able could succeed in science classrooms and that instruction was fast-paced and focused on correct answers negatively predicted science achievement, as measured on a districtwide curriculum-linked test. Shared perceptions that classrooms focused on understanding and independent thinking positively predicted students' self-reported satisfaction with learning. Implications of these results for both teaching and research into classroom environments are discussed.

  10. Highly sensitive beam steering with plasmonic antenna

    PubMed Central

    Rui, Guanghao; Zhan, Qiwen

    2014-01-01

    In this work, we design and study a highly sensitive beam steering device that integrates a spiral plasmonic antenna with a subwavelength metallic waveguide. The short effective wavelength of the surface plasmon polaritons (SPPs) mode supported by the metallic waveguide is exploited to dramatically miniaturize the device and improve the sensitivity of the beam steering. Through introducing a tiny displacement of feed point with respect to the geometrical center of the spiral plasmonic antenna, the direction of the radiation can be steered at considerably high angles. Simulation results show that steering angles of 8°, 17° and 34° are obtainable for a displacement of 50 nm, 100 nm and 200 nm, respectively. Benefiting from the reduced device size and the shorter SPP wavelength, the beam steering sensitivity of the beam steering is improved by 10-fold compared with the case reported previously. This miniature plasmonic beam steering device may find many potential applications in quantum optical information processing and integrated photonic circuits. PMID:25091405

  11. High Sensitivity MEMS Strain Sensor: Design and Simulation

    PubMed Central

    Mohammed, Ahmed A. S.; Moussa, Walied A.; Lou, Edmond

    2008-01-01

    In this article, we report on the new design of a miniaturized strain microsensor. The proposed sensor utilizes the piezoresistive properties of doped single crystal silicon. Employing the Micro Electro Mechanical Systems (MEMS) technology, high sensor sensitivities and resolutions have been achieved. The current sensor design employs different levels of signal amplifications. These amplifications include geometric, material and electronic levels. The sensor and the electronic circuits can be integrated on a single chip, and packaged as a small functional unit. The sensor converts input strain to resistance change, which can be transformed to bridge imbalance voltage. An analog output that demonstrates high sensitivity (0.03mV/με), high absolute resolution (1με) and low power consumption (100μA) with a maximum range of ±4000με has been reported. These performance characteristics have been achieved with high signal stability over a wide temperature range (±50°C), which introduces the proposed MEMS strain sensor as a strong candidate for wireless strain sensing applications under harsh environmental conditions. Moreover, this sensor has been designed, verified and can be easily modified to measure other values such as force, torque…etc. In this work, the sensor design is achieved using Finite Element Method (FEM) with the application of the piezoresistivity theory. This design process and the microfabrication process flow to prototype the design have been presented.

  12. Parent Involvement Practices of High-Achieving Elementary Science Students

    NASA Astrophysics Data System (ADS)

    Waller, Samara Susan

    This study addressed a prevalence of low achievement in science courses in an urban school district in Georgia. National leaders and educators have identified the improvement of science proficiency as critical to the future of American industry. The purpose of this study was to examine parent involvement in this school district and its contribution to the academic achievement of successful science students. Social capital theory guided this study by suggesting that students achieve best when investments are made into their academic and social development. A collective case study qualitative research design was used to interview 9 parent participants at 2 elementary schools whose children scored in the exceeds category on the Science CRCT. The research questions focused on what these parents did at home to support their children's academic achievement. Data were collected using a semi-structured interview protocol and analyzed through the categorical aggregation of transcribed interviews. Key findings revealed that the parents invested time and resources in 3 practices: communicating high expectations, supporting and developing key skills, and communicating with teachers. These findings contribute to social change at both the local and community level by creating a starting point for teachers, principals, and district leaders to reexamine the value of parent input in the educational process, and by providing data to support the revision of current parent involvement policies. Possibilities for further study building upon the findings of this study may focus on student perceptions of their parents' parenting as it relates to their science achievement.

  13. NK sensitivity of neuroblastoma cells determined by a highly sensitive coupled luminescent method

    SciTech Connect

    Ogbomo, Henry; Hahn, Anke; Geiler, Janina; Michaelis, Martin; Doerr, Hans Wilhelm; Cinatl, Jindrich . E-mail: Cinatl@em.uni-frankfurt.de

    2006-01-06

    The measurement of natural killer (NK) cells toxicity against tumor or virus-infected cells especially in cases with small blood samples requires highly sensitive methods. Here, a coupled luminescent method (CLM) based on glyceraldehyde-3-phosphate dehydrogenase release from injured target cells was used to evaluate the cytotoxicity of interleukin-2 activated NK cells against neuroblastoma cell lines. In contrast to most other methods, CLM does not require the pretreatment of target cells with labeling substances which could be toxic or radioactive. The effective killing of tumor cells was achieved by low effector/target ratios ranging from 0.5:1 to 4:1. CLM provides highly sensitive, safe, and fast procedure for measurement of NK cell activity with small blood samples such as those obtained from pediatric patients.

  14. The Will to Achieve: A Phenomenological Study of the Experiences of African American High Achieving Students and Their Parents

    ERIC Educational Resources Information Center

    Spencer, Natalie Faye

    2012-01-01

    The purpose of this research study was to understand the experiences of high achieving African American students and their parents. The experiences of high achieving African American students and their parents have been missing from literature on the academic achievement of African American students. Much of the literature that has been published…

  15. Achieving High Performance on the i860 Microprocessor

    NASA Technical Reports Server (NTRS)

    Lee, King; Kutler, Paul (Technical Monitor)

    1998-01-01

    The i860 is a high performance microprocessor used in the Intel Touchstone project. This paper proposes a paradigm for programming the i860 that is modelled on the vector instructions of the Cray computers. Fortran callable assembler subroutines were written that mimic the concurrent vector instructions of the Cray. Cache takes the place of vector registers. Using this paradigm we have achieved twice the performance of compiled code on a traditional solve.

  16. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity.

    PubMed

    Zhang, Jing; Su, Yan; Shi, Qin; Qiu, An-Ping

    2015-01-01

    This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA). This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF) resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI) processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ) of 48 μg and the bias-instability of 4.8 μg have been achieved. PMID:26633425

  17. Microelectromechanical Resonant Accelerometer Designed with a High Sensitivity

    PubMed Central

    Zhang, Jing; Su, Yan; Shi, Qin; Qiu, An-Ping

    2015-01-01

    This paper describes the design and experimental evaluation of a silicon micro-machined resonant accelerometer (SMRA). This type of accelerometer works on the principle that a proof mass under acceleration applies force to two double-ended tuning fork (DETF) resonators, and the frequency output of two DETFs exhibits a differential shift. The dies of an SMRA are fabricated using silicon-on-insulator (SOI) processing and wafer-level vacuum packaging. This research aims to design a high-sensitivity SMRA because a high sensitivity allows for the acceleration signal to be easily demodulated by frequency counting techniques and decreases the noise level. This study applies the energy-consumed concept and the Nelder-Mead algorithm in the SMRA to address the design issues and further increase its sensitivity. Using this novel method, the sensitivity of the SMRA has been increased by 66.1%, which attributes to both the re-designed DETF and the reduced energy loss on the micro-lever. The results of both the closed-form and finite-element analyses are described and are in agreement with one another. A resonant frequency of approximately 22 kHz, a frequency sensitivity of over 250 Hz per g, a one-hour bias stability of 55 μg, a bias repeatability (1σ) of 48 μg and the bias-instability of 4.8 μg have been achieved. PMID:26633425

  18. [Clinical interpretation of high sensitivity troponin T].

    PubMed

    Alquézar Arbé, Aitor; Santaló Bel, Miguel; Sionis, Alessandro

    2015-09-21

    Determination of cardiac troponin (cTn) is necessary for the diagnosis of acute myocardial infarction without ST segment elevation. However Tnc can be released in other clinical situations. The development of high-sensitive cTn T assays (hs-cTnT) improves the management of patients with suspected acute coronary syndrome. Here, we provide an overview of the diverse causes of hs-cTnT elevation and recommend strategies for the clinical interpretation of the test result. PMID:25620025

  19. Photodetector having high speed and sensitivity

    DOEpatents

    Morse, Jeffrey D.; Mariella, Jr., Raymond P.

    1991-01-01

    The present invention provides a photodetector having an advantageous combination of sensitivity and speed; it has a high sensitivity while retaining high speed. In a preferred embodiment, visible light is detected, but in some embodiments, x-rays can be detected, and in other embodiments infrared can be detected. The present invention comprises a photodetector having an active layer, and a recombination layer. The active layer has a surface exposed to light to be detected, and comprises a semiconductor, having a bandgap graded so that carriers formed due to interaction of the active layer with the incident radiation tend to be swept away from the exposed surface. The graded semiconductor material in the active layer preferably comprises Al.sub.1-x Ga.sub.x As. An additional sub-layer of graded In.sub.1-y Ga.sub.y As may be included between the Al.sub.1-x Ga.sub.x As layer and the recombination layer. The recombination layer comprises a semiconductor material having a short recombination time such as a defective GaAs layer grown in a low temperature process. The recombination layer is positioned adjacent to the active layer so that carriers from the active layer tend to be swept into the recombination layer. In an embodiment, the photodetector may comprise one or more additional layers stacked below the active and recombination layers. These additional layers may include another active layer and another recombination layer to absorb radiation not absorbed while passing through the first layers. A photodetector having a stacked configuration may have enhanced sensitivity and responsiveness at selected wavelengths such as infrared.

  20. Development of High Sensitivity Nuclear Emulsion and Fine Grained Emulsion

    NASA Astrophysics Data System (ADS)

    Kawahara, H.; Asada, T.; Naka, T.; Naganawa, N.; Kuwabara, K.; Nakamura, M.

    2014-08-01

    Nuclear emulsion is a particle detector having high spacial resolution and angular resolution. It became useful for large statistics experiment thanks to the development of automatic scanning system. In 2010, a facility for emulsion production was introduced and R&D of nuclear emulsion began at Nagoya university. In this paper, we present results of development of the high sensitivity emulsion and fine grained emulsion for dark matter search experiment. Improvement of sensitivity is achieved by raising density of silver halide crystals and doping well-adjusted amount of chemicals. Production of fine grained emulsion was difficult because of unexpected crystal condensation. By mixing polyvinyl alcohol (PVA) to gelatin as a binder, we succeeded in making a stable fine grained emulsion.

  1. Experiences of High-Achieving High School Students Who Have Taken Multiple Concurrent Advanced Placement Courses

    ERIC Educational Resources Information Center

    Milburn, Kristine M.

    2011-01-01

    Problem: An increasing number of high-achieving American high school students are enrolling in multiple Advanced Placement (AP) courses. As a result, high schools face a growing need to understand the impact of taking multiple AP courses concurrently on the social-emotional lives of high-achieving students. Procedures: This phenomenological…

  2. Generating high temperature tolerant transgenic plants: Achievements and challenges.

    PubMed

    Grover, Anil; Mittal, Dheeraj; Negi, Manisha; Lavania, Dhruv

    2013-05-01

    Production of plants tolerant to high temperature stress is of immense significance in the light of global warming and climate change. Plant cells respond to high temperature stress by re-programming their genetic machinery for survival and reproduction. High temperature tolerance in transgenic plants has largely been achieved either by over-expressing heat shock protein genes or by altering levels of heat shock factors that regulate expression of heat shock and non-heat shock genes. Apart from heat shock factors, over-expression of other trans-acting factors like DREB2A, bZIP28 and WRKY proteins has proven useful in imparting high temperature tolerance. Besides these, elevating the genetic levels of proteins involved in osmotic adjustment, reactive oxygen species removal, saturation of membrane-associated lipids, photosynthetic reactions, production of polyamines and protein biosynthesis process have yielded positive results in equipping transgenic plants with high temperature tolerance. Cyclic nucleotide gated calcium channel proteins that regulate calcium influxes across the cell membrane have recently been shown to be the key players in induction of high temperature tolerance. The involvement of calmodulins and kinases in activation of heat shock factors has been implicated as an important event in governing high temperature tolerance. Unfilled gaps limiting the production of high temperature tolerant transgenic plants for field level cultivation are discussed.

  3. Highly Sensitive Electro-Optic Modulators

    SciTech Connect

    DeVore, Peter S

    2015-10-26

    There are very important diagnostic and communication applications that receive faint electrical signals to be transmitted over long distances for capture. Optical links reduce bandwidth and distance restrictions of metal transmission lines; however, such signals are only weakly imprinted onto the optical carrier, resulting in low fidelity transmission. Increasing signal fidelity often necessitates insertion of radio-frequency (RF) amplifiers before the electro-optic modulator, but (especially at high frequencies) RF amplification results in large irreversible distortions. We have investigated the feasibility of a Sensitive and Linear Modulation by Optical Nonlinearity (SALMON) modulator to supersede RF-amplified modulators. SALMON uses cross-phase modulation, a manifestation of the Kerr effect, to enhance the modulation depth of an RF-modulated optical wave. This ultrafast process has the potential to result in less irreversible distortions as compared to a RF-amplified modulator due to the broadband nature of the Kerr effect. Here, we prove that a SALMON modulator is a feasible alternative to an RFamplified modulator, by demonstrating a sensitivity enhancement factor greater than 20 and significantly reduced distortion.

  4. A Study to Assess the Achievement Motivation of Higher Secondary Students in Relation to Their Noise Sensitivity

    ERIC Educational Resources Information Center

    Latha, Prema

    2014-01-01

    Disturbing sounds are often referred to as noise, and if extreme enough in degree, intensity or frequency, it is referred to as noise pollution. Achievement refers to a change in study behavior in relation to their noise sensitivity and learning in the educational sense by achieving results in changed responses to certain types of stimuli like…

  5. A high sensitive roll angle interferometer

    NASA Astrophysics Data System (ADS)

    Le, Yanfen; Hou, Wenmei; Hu, Kai; Ju, Aisong

    2013-01-01

    A roll angle interferometer with high sensitivity is designed in this paper. Two sets of centrosymmetric beams are used to travel through the measurement and reference arms of the roll angle interferometer which contains two specific optical devices: wedge prism assembly and wedge mirror assembly. The optical path change in both arms caused by roll is converted into phase shift which can be measured by interferometer. Because of the adoption of the centrosymmetric measurement structure, the straightness errors, yaw error and pitch error can be avoided and the dead path is minimized, so that the stability and the accuracy of the measurement can be greatly enhanced. The resolution for the roll measurement is about 0.006″ with the measurement range of ±1°.

  6. Highly sensitive silicon microreactor for catalyst testing

    SciTech Connect

    Henriksen, Toke R.; Hansen, Ole; Olsen, Jakob L.; Vesborg, Peter; Chorkendorff, Ib

    2009-12-15

    A novel microfabricated chemical reactor for highly sensitive measurements of catalytic activity and surface kinetics is presented. The reactor is fabricated in a silicon chip and is intended for gas-phase reactions at pressures ranging from 0.1 to 5.0 bar. A high sensitivity is obtained by directing the entire gas flow through the catalyst bed to a mass spectrometer, thus ensuring that nearly all reaction products are present in the analyzed gas flow. Although the device can be employed for testing a wide range of catalysts, the primary aim of the design is to allow characterization of model catalysts which can only be obtained in small quantities. Such measurements are of significant fundamental interest but are challenging because of the low surface areas involved. The relationship between the reaction zone gas flow and the pressure in the reaction zone is investigated experimentally. A corresponding theoretical model is presented, and the gas flow through an on-chip flow-limiting capillary is predicted to be in the intermediate regime. The experimental data for the gas flow are found to be in good agreement with the theoretical model. At typical experimental conditions, the total gas flow through the reaction zone is around 3x10{sup 14} molecules s{sup -1}, corresponding to a gas residence time in the reaction zone of about 11 s. To demonstrate the operation of the microreactor, CO oxidation on low-area platinum thin film circles is employed as a test reaction. Using temperature ramping, it is found that platinum catalysts with areas as small as 15 {mu}m{sup 2} are conveniently characterized with the device.

  7. Unlocking Emergent Talent: Supporting High Achievement of Low-Income, High Ability Students

    ERIC Educational Resources Information Center

    Olszewski-Kubilius, Paula; Clarenbach, Jane

    2012-01-01

    This report takes a comprehensive look at achievement for low-income promising learners--past, present, and future. At its core, it challenges the nation to move beyond its near-singular focus of achieving minimum performance for all students, to identifying and developing the talent of all students who are capable of high achievement, including…

  8. Face Transplantation in a Highly Sensitized Recipient.

    PubMed

    Chandraker, Anil; Arscott, Ramon; Murphy, George; Lian, Christine; Bueno, Ericka; Marty, Francisco; Rennke, Helmut; Milford, Edgar; Tullius, Stefan; Pomahac, Bodhan

    2016-05-01

    Face transplantation was performed in a highly sensitized recipient with positive preoperative crossmatch and subsequent antibody-mediated rejection. The recipient was a 45-year-old female with extensive conventional reconstructions after chemical burns over the majority of the body. Residual quality of life and facial functions were poor. Levels of circulating anti-human leukocyte antigen (HLA) antibodies were high, and panel reactive antibody score was 98%. A potential donor was identified; however, with positive T and B cell flow crossmatches. The transplant team proceeded with face transplantation from this donor, under tailored immune suppression and with available salvage options. The operation was successful. Plasmapheresis and induction immune suppression (i.e., thymoglobulin followed by mycophenolate mofetil, tacrolimus, and steroids) were provided. Five days later, there was significant facial swelling, rising anti-HLA antibody titers, and unprecedented evidence of C4d deposits on skin. High doses of steroids and thymoglobulin were provided; however, rejection increased such that by day 19 it was diagnosed grade III in the BANFF scale. After stopping thymoglobulin because of serum sickness, combination therapy of plasmapheresis, eculizumab, bortezomib, and alemtuzumab was provided. HLA antibody levels decreased while swelling and redness improved. At 3 months, there were no longer signs of rejection on biopsy. PMID:27168576

  9. Large pi-aromatic molecules as potential sensitizers for highly efficient dye-sensitized solar cells.

    PubMed

    Imahori, Hiroshi; Umeyama, Tomokazu; Ito, Seigo

    2009-11-17

    Recently, dye-sensitized solar cells have attracted much attention relevant to global environmental issues. Thus far, ruthenium(II) bipyridyl complexes have proven to be the most efficient TiO(2) sensitizers in dye-sensitized solar cells. However, a gradual increment in the highest power conversion efficiency has been recognized in the past decade. More importantly, considering that ruthenium is a rare metal, novel dyes without metal or using inexpensive metal are desirable for highly efficient dye-sensitized solar cells. Large pi-aromatic molecules, such as porphyrins, phthalocyanines, and perylenes, are important classes of potential sensitizers for highly efficient dye-sensitized solar cells, owing to their photostability and high light-harvesting capabilities that can allow applications in thinner, low-cost dye-sensitized solar cells. Porphyrins possess an intense Soret band at 400 nm and moderate Q bands at 600 nm. Nevertheless, the poor light-harvesting properties relative to the ruthenium complexes have limited the cell performance of porphyrin-sensitized TiO(2) cells. Elongation of the pi conjugation and loss of symmetry in porphyrins cause broadening and a red shift of the absorption bands together with an increasing intensity of the Q bands relative to that of the Soret band. On the basis of the strategy, the cell performance of porphyrin-sensitized solar cells has been improved intensively by the enhanced light absorption. Actually, some push-pull-type porphyrins have disclosed a remarkably high power conversion efficiency (6-7%) that was close to that of the ruthenium complexes. Phthalocyanines exhibit strong absorption around 300 and 700 nm and redox features that are similar to porphyrins. Moreover, phthalocyanines are transparent over a large region of the visible spectrum, thereby enabling the possibility of using them as "photovoltaic windows". However, the cell performance was poor, owing to strong aggregation and lack of directionality in the

  10. Transportable high sensitivity small sample radiometric calorimeter

    SciTech Connect

    Wetzel, J.R.; Biddle, R.S.; Cordova, B.S.; Sampson, T.E.; Dye, H.R.; McDow, J.G.

    1998-12-31

    A new small-sample, high-sensitivity transportable radiometric calorimeter, which can be operated in different modes, contains an electrical calibration method, and can be used to develop secondary standards, will be described in this presentation. The data taken from preliminary tests will be presented to indicate the precision and accuracy of the instrument. The calorimeter and temperature-controlled bath, at present, require only a 30-in. by 20-in. tabletop area. The calorimeter is operated from a laptop computer system using unique measurement module capable of monitoring all necessary calorimeter signals. The calorimeter can be operated in the normal calorimeter equilibration mode, as a comparison instrument, using twin chambers and an external electrical calibration method. The sample chamber is 0.75 in (1.9 cm) in diameter by 2.5 in. (6.35 cm) long. This size will accommodate most {sup 238}Pu heat standards manufactured in the past. The power range runs from 0.001 W to <20 W. The high end is only limited by sample size.

  11. Achieving high energy absorption capacity in cellular bulk metallic glasses

    NASA Astrophysics Data System (ADS)

    Chen, S. H.; Chan, K. C.; Wu, F. F.; Xia, L.

    2015-05-01

    Cellular bulk metallic glasses (BMGs) have exhibited excellent energy-absorption performance by inheriting superior strength from the parent BMGs. However, how to achieve high energy absorption capacity in cellular BMGs is vital but mysterious. In this work, using step-by-step observations of the deformation evolution of a series of cellular BMGs, the underlying mechanisms for the remarkable energy absorption capacity have been investigated by studying two influencing key factors: the peak stress and the decay of the peak stress during the plastic-flow plateau stages. An analytical model of the peak stress has been proposed, and the predicted results agree well with the experimental data. The decay of the peak stress has been attributed to the geometry change of the macroscopic cells, the formation of shear bands in the middle of the struts, and the “work-softening” nature of BMGs. The influencing factors such as the effect of the strut thickness and the number of unit cells have also been investigated and discussed. Strategies for achieving higher energy absorption capacity in cellular BMGs have been proposed.

  12. Achieving high energy absorption capacity in cellular bulk metallic glasses

    PubMed Central

    Chen, S. H.; Chan, K. C.; Wu, F. F.; Xia, L.

    2015-01-01

    Cellular bulk metallic glasses (BMGs) have exhibited excellent energy-absorption performance by inheriting superior strength from the parent BMGs. However, how to achieve high energy absorption capacity in cellular BMGs is vital but mysterious. In this work, using step-by-step observations of the deformation evolution of a series of cellular BMGs, the underlying mechanisms for the remarkable energy absorption capacity have been investigated by studying two influencing key factors: the peak stress and the decay of the peak stress during the plastic-flow plateau stages. An analytical model of the peak stress has been proposed, and the predicted results agree well with the experimental data. The decay of the peak stress has been attributed to the geometry change of the macroscopic cells, the formation of shear bands in the middle of the struts, and the “work-softening” nature of BMGs. The influencing factors such as the effect of the strut thickness and the number of unit cells have also been investigated and discussed. Strategies for achieving higher energy absorption capacity in cellular BMGs have been proposed. PMID:25973781

  13. Relationship of Gender and Academic Achievement to Finnish Students' Intercultural Sensitivity

    ERIC Educational Resources Information Center

    Holm, Kristiina; Nokelainen, Petri; Tirri, Kirsi

    2009-01-01

    This study examined the intercultural sensitivity of Finnish 12-16-year-old secondary school students (N=549) with a 23-item Intercultural Sensitivity Scale Questionnaire (ICSSQ). The ICSSQ is based on Bennett's (1993) Developmental Model of Intercultural Sensitivity (DMIS), which is a conceptual tool to situate certain reactions towards cultural…

  14. Achieving High Resolution Timer Events in Virtualized Environment

    PubMed Central

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs—Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events. PMID:26177366

  15. Achieving High Resolution Timer Events in Virtualized Environment.

    PubMed

    Adamczyk, Blazej; Chydzinski, Andrzej

    2015-01-01

    Virtual Machine Monitors (VMM) have become popular in different application areas. Some applications may require to generate the timer events with high resolution and precision. This however may be challenging due to the complexity of VMMs. In this paper we focus on the timer functionality provided by five different VMMs-Xen, KVM, Qemu, VirtualBox and VMWare. Firstly, we evaluate resolutions and precisions of their timer events. Apparently, provided resolutions and precisions are far too low for some applications (e.g. networking applications with the quality of service). Then, using Xen virtualization we demonstrate the improved timer design that greatly enhances both the resolution and precision of achieved timer events. PMID:26177366

  16. Design considerations for achieving high vacuum integrity in fusion devices

    SciTech Connect

    Fuller, G.M.; Haines, J.R.

    1983-01-01

    Achieving high vacuum integrity in fusion devices requires close attention to both the overall system configuration and the design details of joints and seals. This paper describes the factors in selecting the system configuration, from a vacuum standpoint, for the Princeton Plasma Physics Laboratory (PPPL) DCT-8 Tokamak device. The DCT-8 (driven current tokamak) is the eighth design in a series of tokamak concepts defined to cover the magnetic confinement and development gap between the Tokamak Fusion Test Reactor (TFTR) and the Engineering Test Reactor (ETR). Leak detection concept development is considered a vital activity, as well as the definition of a configuration that minimizes the consequences of leaks. A major part of the vacuum boundaries of the magnet system and the plasma system is common. For the major penetrations, primary and secondary seals are provided with vacuum control over the region between seals. The intent is to instrument these cavities and provide automated recordings of these measurements for leak maintenance.

  17. NETD test of high-sensitivity infrared camera

    NASA Astrophysics Data System (ADS)

    Li, Yingwen; Pan, Debin; Yang, Changcheng; Luo, Yan

    2007-12-01

    Infrared camera has more and more application in military, judicature, rescue, industry, hospital and science. Nowadays the NETD (Noise Equivalent Temperature Difference) of high-sensitivity cooled infrared camera is less than 10 mK. If we test the NETD from the analog video output port of infrared camera using 8-bit and 10-bit ADC frame grabber, the NETD accuracy is 7.81 mK and 2.76 mK which correspond to relative error 78.7% and 27.6% for a 10 mK NETD infrared camera. Such kind of accuracy is obviously not proper for the performance evaluation of high-sensitivity infrared camera with NETD less than 10 mK. The NETD test accuracy can be improved by increasing the effective bit number of the ADC of frame grabber. The quantization error of ADC of frame grabber has become the main factor which contributes most to the NETD error of the high-sensitivity infrared camera. It is difficult to evaluate the electrooptical performance of the high-sensitivity infrared camera through its analog video. Although the NETD test accuracy can be improved by reducing the linear temperature range or increasing the effective bits of the ADC of frame grabber under analog video interface test condition, it is difficult to meet the test needs. But under the 14 bits digital video interface test condition and 1 K linear range, the NETD test accuracy of 0.24 mK can be achieved. The NETD accuracy can be also improved by reducing the linear temperature range. The NETD test accuracy can be 0.488 mK through 14-bit digital video under 2 K linear temperature range and its relative error equals 4.9% for a 10 mK NETD high-sensitivity infrared camera which meets the requirement. The test result through the digital video port of an infrared camera shows that the test result through digital video port matches with its nominal value. This necessitates the need of digital video interface of high-sensitivity infrared camera in NETD test in order to evaluate its performance accuracy.

  18. Achieving ultra-high temperatures with a resistive emitter array

    NASA Astrophysics Data System (ADS)

    Danielson, Tom; Franks, Greg; Holmes, Nicholas; LaVeigne, Joe; Matis, Greg; McHugh, Steve; Norton, Dennis; Vengel, Tony; Lannon, John; Goodwin, Scott

    2016-05-01

    The rapid development of very-large format infrared detector arrays has challenged the IR scene projector community to also develop larger-format infrared emitter arrays to support the testing of systems incorporating these detectors. In addition to larger formats, many scene projector users require much higher simulated temperatures than can be generated with current technology in order to fully evaluate the performance of their systems and associated processing algorithms. Under the Ultra High Temperature (UHT) development program, Santa Barbara Infrared Inc. (SBIR) is developing a new infrared scene projector architecture capable of producing both very large format (>1024 x 1024) resistive emitter arrays and improved emitter pixel technology capable of simulating very high apparent temperatures. During earlier phases of the program, SBIR demonstrated materials with MWIR apparent temperatures in excess of 1400 K. New emitter materials have subsequently been selected to produce pixels that achieve even higher apparent temperatures. Test results from pixels fabricated using the new material set will be presented and discussed. A 'scalable' Read In Integrated Circuit (RIIC) is also being developed under the same UHT program to drive the high temperature pixels. This RIIC will utilize through-silicon via (TSV) and Quilt Packaging (QP) technologies to allow seamless tiling of multiple chips to fabricate very large arrays, and thus overcome the yield limitations inherent in large-scale integrated circuits. Results of design verification testing of the completed RIIC will be presented and discussed.

  19. Demonstration of high sensitivity laser ranging system

    NASA Technical Reports Server (NTRS)

    Millar, Pamela S.; Christian, Kent D.; Field, Christopher T.

    1994-01-01

    We report on a high sensitivity semiconductor laser ranging system developed for the Gravity and Magnetic Earth Surveyor (GAMES) for measuring variations in the planet's gravity field. The GAMES laser ranging instrument (LRI) consists of a pair of co-orbiting satellites, one which contains the laser transmitter and receiver and one with a passive retro-reflector mounted in an drag-stabilized housing. The LRI will range up to 200 km in space to the retro-reflector satellite. As the spacecraft pair pass over the spatial variations in the gravity field, they experience along-track accelerations which change their relative velocity. These time displaced velocity changes are sensed by the LRI with a resolution of 20-50 microns/sec. In addition, the pair may at any given time be drifting together or apart at a rate of up to 1 m/sec, introducing a Doppler shift into the ranging signals. An AlGaAs laser transmitter intensity modulated at 2 GHz and 10 MHz is used as fine and medium ranging channels. Range is measured by comparing phase difference between the transmit and received signals at each frequency. A separate laser modulated with a digital code, not reported in this paper, will be used for coarse ranging to unambiguously determine the distance up to 200 km.

  20. Pre-Type 1 Diabetes Dysmetabolism: Maximal sensitivity achieved with Both Oral and Intravenous Glucose Tolerance Testing

    PubMed Central

    Barker, Jennifer M.; McFann, Kim; Harrison, Leonard C.; Fourlanos, Spiros; Krischer, Jeffrey; Cuthbertson, David; Chase, H. Peter; Eisenbarth, George S.; Group, the DPT-1 Study

    2007-01-01

    Objective To determine the relationship of intravenous (IVGTT) and oral (OGTT) glucose tolerance tests abnormalities to diabetes development in a high-risk pre-diabetic cohort and identify an optimal testing strategy for detecting pre-clinical diabetes. Study design Diabetes Prevention Trial Type 1 randomized subjects to oral (n=372) and parenteral (n=339) insulin prevention trials. Subjects were followed with IVGTTs and OGTTs. Factors associated with progression to diabetes were evaluated. Results Survival analysis revealed that higher quartiles of 2-hour glucose and lower quartiles of FPIR at baseline were associated with decreased diabetes-free survival. Cox proportional hazards modeling showed that baseline BMI, FPIR and 2-hour glucose levels were significantly associated with an increased hazard for diabetes. On testing performed within 6 months of diabetes diagnosis, 3% (1/32) had normal first phase insulin response (FPIR) and normal 2-hour glucose on OGTT. The sensitivities for impaired glucose tolerance (IGT) and low FPIR performed within 6 months of diabetes diagnosis were equivalent (76% vs. 73%). Conclusions Most (97%) subjects had abnormal IVGTTs and/or OGTTs prior to the development of diabetes. The highest sensitivity is achieved using both tests. PMID:17188609

  1. How to achieve high-level expression of microbial enzymes

    PubMed Central

    Liu, Long; Yang, Haiquan; Shin, Hyun-dong; Chen, Rachel R.; Li, Jianghua; Du, Guocheng; Chen, Jian

    2013-01-01

    Microbial enzymes have been used in a large number of fields, such as chemical, agricultural and biopharmaceutical industries. The enzyme production rate and yield are the main factors to consider when choosing the appropriate expression system for the production of recombinant proteins. Recombinant enzymes have been expressed in bacteria (e.g., Escherichia coli, Bacillus and lactic acid bacteria), filamentous fungi (e.g., Aspergillus) and yeasts (e.g., Pichia pastoris). The favorable and very advantageous characteristics of these species have resulted in an increasing number of biotechnological applications. Bacterial hosts (e.g., E. coli) can be used to quickly and easily overexpress recombinant enzymes; however, bacterial systems cannot express very large proteins and proteins that require post-translational modifications. The main bacterial expression hosts, with the exception of lactic acid bacteria and filamentous fungi, can produce several toxins which are not compatible with the expression of recombinant enzymes in food and drugs. However, due to the multiplicity of the physiological impacts arising from high-level expression of genes encoding the enzymes and expression hosts, the goal of overproduction can hardly be achieved, and therefore, the yield of recombinant enzymes is limited. In this review, the recent strategies used for the high-level expression of microbial enzymes in the hosts mentioned above are summarized and the prospects are also discussed. We hope this review will contribute to the development of the enzyme-related research field. PMID:23686280

  2. High-sensitivity uncooled microcantilever infrared imaging arrays

    NASA Astrophysics Data System (ADS)

    Hunter, Scott R.; Maurer, Gregory; Jiang, Lijun; Simelgor, Gregory

    2006-05-01

    The design and operation of an advanced bimorph microcantilever based infrared imaging detector are presented. This technology has the potential to achieve very high sensitivities due to its inherent high responsivity and low noise sensor and detection electronics. The sensor array is composed of bimaterial, thermally sensitive microcantilever structures that are the moving elements of variable plate capacitors. The heat sensing microcantilever structures are integrated with CMOS control and amplification electronics to produce a low cost imager that is compatible with standard silicon IC foundry processing and materials. The bimorph sensor structure is fabricated using low thermal expansion, high thermal isolation silicon oxide and oxynitride materials, and a high thermal expansion aluminum alloy bimetal. The microcantilever paddle is designed to move away from the substrate at elevated imaging temperatures, leading to large modeled sensor dynamic ranges (~16 bits). A temperature coefficient of capacitance, ▵C/C, (equivalent to TCR for microbolometers) above 30% has been modeled and measured for these structures, leading to modeled NEDT < 20 mK and thermal time constants in the 5-10 msec range giving a figure-of-merit [1] NEDT.Tau = 100-200 mK.msec. The development efforts to date have focused on the fabrication of 160x120 pixel arrays with 50 micron pitch pixels. Results from detailed thermo-electro-opto-mechanical modeling of the operation of these sensors are compared with experimental measurements from various test and integrated sensor structures and arrays.

  3. Comparison of the Level of Using Metacognitive Strategies during Study between High Achieving and Low Achieving Prospective Teachers

    ERIC Educational Resources Information Center

    Doganay, Ahmet; Demir, Ozden

    2011-01-01

    The main purpose of this study is to compare the level of using metacognitive strategies during study between high achieving and low achieving prospective classroom teachers. This study was designed as a mixed method study. Metacognitive Learning Strategies Scale developed by Namlu (2004) was used to measure the use of metacognitive strategies…

  4. Effects of Partner's Ability on the Achievement and Conceptual Organization of High-Achieving Fifth-Grade Students.

    ERIC Educational Resources Information Center

    Carter, Glenda; Jones, M. Gail; Rua, Melissa

    2003-01-01

    Investigates high-achieving fifth-grade students' achievement gains and conceptual reorganization on convection. Features an instructional sequence of three dyadic inquiry investigations related to convection currents as well as pre- and post-assessment consisting of a multiple-choice test, a card sorting task, construction of a concept map, and…

  5. Gender Differences in Attitudes toward Mathematics between Low-Achieving and High-Achieving Fifth Grade Elementary Students.

    ERIC Educational Resources Information Center

    Rathbone, A. Sue

    Possible gender differences in attitudes toward mathematics were studied between low-achieving and high-achieving fifth-grade students in selected elementary schools within a large, metropolitan area. The attitudes of pre-adolescent children at an intermediate grade level were assessed to determine the effects of rapidly emerging gender-related…

  6. Design of a charge sensitive preamplifier on high resistivity silicon

    SciTech Connect

    Radeka, V.; Rehak, P.; Rescia, S.; Gatti, E.; Longoni, A.; Sampietro, M.; Holl, P.; Strueder, L.; Kemmer, J.

    1987-01-01

    A low noise, fast charge sensitive preamplifier was designed on high resistivity, detector grade silicon. It is built at the surface of a fully depleted region of n-type silicon. This allows the preamplifier to be placed very close to a detector anode. The preamplifier uses the classical input cascode configuration with a capacitor and a high value resistor in the feedback loop. The output stage of the preamplifier can drive a load up to 20pF. The power dissipation of the preamplifier is 13mW. The amplifying elements are ''Single Sided Gate JFETs'' developed especially for this application. Preamplifiers connected to a low capacitance anode of a drift type detector should achieve a rise time of 20ns and have an equivalent noise charge (ENC), after a suitable shaping, of less than 50 electrons. This performance translates to a position resolution better than 3..mu..m for silicon drift detectors. 6 refs., 9 figs.

  7. Achieving High Throughput for Data Transfer over ATM Networks

    NASA Technical Reports Server (NTRS)

    Johnson, Marjory J.; Townsend, Jeffrey N.

    1996-01-01

    File-transfer rates for ftp are often reported to be relatively slow, compared to the raw bandwidth available in emerging gigabit networks. While a major bottleneck is disk I/O, protocol issues impact performance as well. Ftp was developed and optimized for use over the TCP/IP protocol stack of the Internet. However, TCP has been shown to run inefficiently over ATM. In an effort to maximize network throughput, data-transfer protocols can be developed to run over UDP or directly over IP, rather than over TCP. If error-free transmission is required, techniques for achieving reliable transmission can be included as part of the transfer protocol. However, selected image-processing applications can tolerate a low level of errors in images that are transmitted over a network. In this paper we report on experimental work to develop a high-throughput protocol for unreliable data transfer over ATM networks. We attempt to maximize throughput by keeping the communications pipe full, but still keep packet loss under five percent. We use the Bay Area Gigabit Network Testbed as our experimental platform.

  8. Student Perception of Academic Achievement Factors at High School

    ERIC Educational Resources Information Center

    Bahar, Mustafa

    2016-01-01

    Measuring the quality of the "product" is elemental in education, and most studies depend on observational data about student achievement factors, focusing overwhelmingly on quantitative data namely achievement scores, school data like attendance, facilities, expenditure class size, etc. But there is little evidence of learner…

  9. Learning Styles and High School Students' Chemistry Achievement

    ERIC Educational Resources Information Center

    Uzuntiryaki, Esen

    2007-01-01

    The aim of the present study was to investigate the effects of students' learning styles on their chemistry achievement, and whether matching between teaching and learning styles also affects students' chemistry achievement. Two hundred and sixty-five tenth-grade students enrolled in a chemistry course and seven chemistry teachers participated in…

  10. Does Recreational Computer Use Affect High School Achievement?

    ERIC Educational Resources Information Center

    Bowers, Alex J.; Berland, Matthew

    2013-01-01

    Historically, the relationship between student academic achievement and use of computers for fun and video gaming has been described from a multitude of perspectives, from positive, to negative, to neutral. However, recent research has indicated that computer use and video gaming may be positively associated with achievement, yet these studies…

  11. High-Achieving High School Students and Not so High-Achieving College Students: A Look at Lack of Self-Control, Academic Ability, and Performance in College

    ERIC Educational Resources Information Center

    Honken, Nora B.; Ralston, Patricia A. S.

    2013-01-01

    This study investigated the relationship among lack of self-control, academic ability, and academic performance for a cohort of freshman engineering students who were, with a few exceptions, extremely high achievers in high school. Structural equation modeling analysis led to the conclusion that lack of self-control in high school, as measured by…

  12. A case of high noise sensitivity

    NASA Astrophysics Data System (ADS)

    Murata, M.; Sakamoto, H.

    1995-10-01

    A case of noise sensitivity with a five-year follow-up period is reported. The patient was a 34-year-old single man who was diagnosed as having psychosomatic disorder triggered by two stressful life events in rapid succession with secondary hypersensitivity to noise. Hypersensitivity to light and cold also developed later in the clinical course. The auditory threshold was within the normal range. The discomfort threshold as a measure of the noise sensitivity secondary to mental illness was measured repeatedly using test tone of audiometry. The discomfort threshold varied depending upon his mental status, ranging from 40-50 dB in the comparatively poorer mental state to 70-95 dB in the relatively good mental state. The features of noise sensitivity, including that secondary to mental illness, are discussed.

  13. Achievement of Hispanic Students in American High Schools: Background Characteristics and Achievement. Contractor Report.

    ERIC Educational Resources Information Center

    Nielsen, Francois; Fernandez, Roberto M.

    Presenting data and analyses from the first wave of the study "High School and Beyond" (HS&B), a longitudinal study of United States high school sophomores and seniors, the report focuses on the composition of the Hispanic tenth and twelfth grade student population with respect to various characteristics; i.e., language use and proficiency, length…

  14. High performances CNTFETs achieved using CNT networks for selective gas sensing

    NASA Astrophysics Data System (ADS)

    Gorintin, Louis; Bondavalli, Paolo; Legagneux, Pierre; Pribat, Didier

    2009-08-01

    Our study deals with the utilization of carbon nanotubes networks based transistors with different metal electrodes for highly selective gas sensing. Indeed, carbon nanotubes networks can be used as semi conducting materials to achieve good performances transistors. These devices are extremely sensitive to the change of the Schottky barrier heights between Single Wall Carbon Nanotubes (SWCNTs) and drain/source metal electrodes: the gas adsorption creates an interfacial dipole that modifies the metal work function and so the bending and the height of the Schottky barrier at the contacts. Moreover each gas interacts specifically with each metal identifying a sort of electronic fingerprinting. Using airbrush technique for deposition, we have been able to achieve uniform random networks of carbon nanotubes suitable for large area applications and mass production such as fabrication of CNT based gas sensors. These networks enable us to achieve transistors with on/off ratio of more than 5 orders of magnitude. To reach these characteristics, the density of the CNT network has been adjusted in order to reach the percolation threshold only for semi-conducting nanotubes. These optimized devices have allowed us to tune the sensitivity (improving it) of our sensors for highly selective detection of DiMethyl-Methyl-Phosphonate (DMMP, a sarin stimulant), and even volatile drug precursors using Pd, Au and Mo electrodes.

  15. Preferences of High Achieving High School Students in Their Career Development

    ERIC Educational Resources Information Center

    Kim, Mihyeon

    2010-01-01

    The intent of this study was to identify the needs and preference of high-achieving high school students. In terms of career related programs in high school, students listed AP courses and mentoring as their preferred career-related programs. Also, students stated that career guidance by counselors, workshops or sessions, and tech prep were the…

  16. Threatened and Placed at Risk: High Achieving African American Males in Urban High Schools

    ERIC Educational Resources Information Center

    McGee, Ebony O.

    2013-01-01

    This study investigated the risk and protective factors of 11 high-achieving African American males attending 4 urban charter high schools in a Midwestern city to determine what factors account for their resilience and success in mathematics courses, and in high school more generally. This research was guided by a Phenomenological Variant of…

  17. Highly sensitive Raman system for dissolved gas analysis in water.

    PubMed

    Yang, Dewang; Guo, Jinjia; Liu, Qingsheng; Luo, Zhao; Yan, Jingwen; Zheng, Ronger

    2016-09-20

    The detection of dissolved gases in seawater plays an important role in ocean observation and exploration. As a potential technique for oceanic applications, Raman spectroscopy has already proved its advantages in the simultaneous detection of multiple species during previous deep-sea explorations. Due to the low sensitivity of conventional Raman measurements, there have been many reports of Raman applications on direct seawater detection in high-concentration areas, but few on undersea dissolved gas detection. In this work, we have presented a highly sensitive Raman spectroscopy (HSRS) system with a special designed gas chamber for small amounts of underwater gas extraction. Systematic experiments have been carried out for system evaluation, and the results have shown that the Raman signals obtained by the innovation of a near-concentric cavity was about 21 times stronger than those of conventional side-scattering Raman measurements. Based on this system, we have achieved a low limit of detection of 2.32 and 0.44  μmol/L for CO2 and CH4, respectively, in the lab. A test-out experiment has also been accomplished with a gas-liquid separator coupled to the Raman system, and signals of O2 and CO2 were detected after 1 h of degasification. This system may show potential for gas detection in water, and further work would be done for the improvement of in situ detection.

  18. Highly sensitive Raman system for dissolved gas analysis in water.

    PubMed

    Yang, Dewang; Guo, Jinjia; Liu, Qingsheng; Luo, Zhao; Yan, Jingwen; Zheng, Ronger

    2016-09-20

    The detection of dissolved gases in seawater plays an important role in ocean observation and exploration. As a potential technique for oceanic applications, Raman spectroscopy has already proved its advantages in the simultaneous detection of multiple species during previous deep-sea explorations. Due to the low sensitivity of conventional Raman measurements, there have been many reports of Raman applications on direct seawater detection in high-concentration areas, but few on undersea dissolved gas detection. In this work, we have presented a highly sensitive Raman spectroscopy (HSRS) system with a special designed gas chamber for small amounts of underwater gas extraction. Systematic experiments have been carried out for system evaluation, and the results have shown that the Raman signals obtained by the innovation of a near-concentric cavity was about 21 times stronger than those of conventional side-scattering Raman measurements. Based on this system, we have achieved a low limit of detection of 2.32 and 0.44  μmol/L for CO2 and CH4, respectively, in the lab. A test-out experiment has also been accomplished with a gas-liquid separator coupled to the Raman system, and signals of O2 and CO2 were detected after 1 h of degasification. This system may show potential for gas detection in water, and further work would be done for the improvement of in situ detection. PMID:27661606

  19. The Effect of Music Participation on Mathematical Achievement and Overall Academic Achievement of High School Students

    ERIC Educational Resources Information Center

    Cox, H. A.; Stephens, L. J.

    2006-01-01

    A study was conducted on high school students, comparing those with some music credits to those with none. No statistically significant difference was found in their mean math grade point averages (GPA) or their mean cumulative GPAs. Students were then separated into two groups based on the number of music credits. Students who had earned at least…

  20. High sensitivity leak detection method and apparatus

    DOEpatents

    Myneni, Ganapatic R.

    1994-01-01

    An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1.times.10.sup.-18 atm cc sec.sup.-1.

  1. High sensitivity leak detection method and apparatus

    DOEpatents

    Myneni, G.R.

    1994-09-06

    An improved leak detection method is provided that utilizes the cyclic adsorption and desorption of accumulated helium on a non-porous metallic surface. The method provides reliable leak detection at superfluid helium temperatures. The zero drift that is associated with residual gas analyzers in common leak detectors is virtually eliminated by utilizing a time integration technique. The sensitivity of the apparatus of this disclosure is capable of detecting leaks as small as 1 [times] 10[sup [minus]18] atm cc sec[sup [minus]1]. 2 figs.

  2. Highly sensitive genotyping using artificial riboregulator system.

    PubMed

    Narita, Atsushi; Ogawa, Kazumasa; Sando, Shinsuke; Aoyama, Yasuhiro

    2005-01-01

    A molecular-beacon-type riboregulator (mRNA) was applied to multiply catalytic gene sensing. It consists of a reporter gene for firefly protein luciferase and, upstream thereof, a regulator hairpin domain composed of an RBS/anti-RBS stem (RBS = ribosome binding site) and a loop which is complementary to the target. The sensing of target gene, using an unmodified RNA or even dsDNA as a probe with a chemiluminescence output, was demonstrated with a sensitivity at < or = 50 fmol of the target and a single nucleotide resolution.

  3. "Brains before "Beauty"?" High Achieving Girls, School and Gender Identities

    ERIC Educational Resources Information Center

    Skelton, Christine; Francis, Becky; Read, Barbara

    2010-01-01

    In recent years educational policy on gender and achievement has concentrated on boys' underachievement, frequently comparing it with the academic success of girls. This has encouraged a perception of girls as the "winners" of the educational stakes and assumes that they no longer experience the kinds of gender inequalities identified in earlier…

  4. High-Achieving Middle Schools for Latino Students in Poverty

    ERIC Educational Resources Information Center

    Jesse, Dan; Davis, Alan; Pokorny, Nancy

    2004-01-01

    This study was conducted to examine the characteristics of middle schools in which Latino students from low-income families made substantial achievement gains. Nine schools in Texas were selected where Latino students had shown strong gains in the Texas Assessment of Academic Skills. Data from onsite interviews, focus groups, and documents were…

  5. Dominant Achievement Goals across Tracks in High School

    ERIC Educational Resources Information Center

    Scheltinga, Peter A. M.; Kuyper, Hans; Timmermans, Anneke C.; van der Werf, Greetje P. C.

    2016-01-01

    The dominant achievement goals (DAGs) of 7,008 students in the third grade of Dutch secondary education (US grade 9) were investigated, based on Elliot & McGregors' 2 × 2 framework (2001), in relation to track-level and motivational variables. We found the mastery-approach goal and the performance-approach goal, generally considered adaptive,…

  6. A high sensitive phosphor for dosimetric applications

    SciTech Connect

    Kore, Bhushan P. Dhoble, S. J.; Dhoble, N. S.; Lochab, S. P.

    2015-06-24

    In this study a novel TL phosphor CaMg{sub 3}(SO{sub 4}){sub 4}:Dy{sup 3+} was prepared by acid distillation method. The TL response of this phosphor towards γ-rays and carbon ion beam was tested. Good dosimetric glow curve was observed which is stable against both the type of radiations. The CaMg{sub 3}(SO{sub 4}){sub 4}:Dy{sup 3+} phosphor doped with 0.2 mol% of Dy{sup 3+}, irradiated with γ-ray shows nearly equal sensitivity to that of commercially available CaSO{sub 4}:Dy TLD phosphor whereas 3.5 times more sensitivity than CaSO{sub 4}:Dy, when irradiated with carbon ion beam. The change in glow peak intensities and glow peak temperature with variation in irradiation species and energy of ion beam is discussed here. The effect of these on trapping parameters is also illustrated.

  7. High-sensitivity and wide-directivity ultrasound detection using high Q polymer microring resonators

    PubMed Central

    Ling, Tao; Chen, Sung-Liang; Guo, L. Jay

    2011-01-01

    Small size ultrahigh Q polymer microrings working at near visible wavelength have been experimentally demonstrated as ultralow noise ultrasound detectors with wide directivity at high frequencies (>20 MHz). By combining a resist reflow and a low bias continuous etching and passivation process in mold fabrication, imprinted polymer microrings with drastically improved sidewall smoothness were obtained. An ultralow noise-equivalent pressure of 21.4 Pa over 1–75 MHz range has been achieved using a fabricated detector of 60 μm diameter. The device’s wide acceptance angle with high sensitivity considerably benefits ultrasound-related imaging. PMID:21673832

  8. Success Despite Socioeconomics: A Case Study of a High-Achieving, High-Poverty School

    ERIC Educational Resources Information Center

    Tilley, Thomas Brent; Smith, Samuel J.; Claxton, Russell L.

    2012-01-01

    This case study of a high-achieving, high-poverty school describes the school's leadership, culture, and programs that contributed to its success. Data were collected from two surveys (the School Culture Survey and the Vanderbilt Assessment of Leadership in Education), observations at the school site, and interviews with school personnel. The…

  9. Parenting Style, Perfectionism, and Creativity in High-Ability and High-Achieving Young Adults

    ERIC Educational Resources Information Center

    Miller, Angie L.; Lambert, Amber D.; Speirs Neumeister, Kristie L.

    2012-01-01

    The current study explores the potential relationships among perceived parenting style, perfectionism, and creativity in a high-ability and high-achieving young adult population. Using data from 323 honors college students at a Midwestern university, bivariate correlations suggested positive relationships between (a) permissive parenting style and…

  10. A highly sensitive fiber Bragg grating diaphragm pressure transducer

    NASA Astrophysics Data System (ADS)

    Allwood, Gary; Wild, Graham; Lubansky, Alex; Hinckley, Steven

    2015-10-01

    In this work, a novel diaphragm based pressure transducer with high sensitivity is described, including the physical design structure, in-depth analysis of optical response to changes in pressure, and a discussion of practical implementation and limitations. A flat circular rubber membrane bonded to a cylinder forms the body of the transducer. A fiber Bragg grating bonded to the center of the diaphragm structure enables the fractional change in pressure to be determined by analyzing the change in Bragg wavelength of the reflected spectra. Extensive evaluation of the physical properties and optical characteristics of the transducer has been performed through experimentation, and modeling using small deformation theory. The results show the transducer has a sensitivity of 0.116 nm/kPa, across a range of 15 kPa. Ultra-low cost interrogation of the optical signal was achieved through the use of an optically mismatched Bragg grating acting as an edge filter to convert the spectral change into an intensity change. A numerical model of the intensity based interrogation was implemented in order to validate the experimental results. Utilizing this interrogation technique and housing both the sensing and reference Bragg gratings within the main body of the transducer means it is effectively temperature insensitive and easily connected to electronic systems.

  11. PlanetPol: A Very High Sensitivity Polarimeter

    NASA Astrophysics Data System (ADS)

    Hough, J. H.; Lucas, P. W.; Bailey, J. A.; Tamura, M.; Hirst, E.; Harrison, D.; Bartholomew-Biggs, M.

    2006-09-01

    We have built and used on several occasions an optical broadband stellar polarimeter, PlanetPol, which employs photoelastic modulators and avalanche photodiodes and achieves a photon-noise-limited sensitivity of at least 1 in 106 in fractional polarization. Observations of a number of polarized standards taken from the literature show that the accuracy of polarization measurements is ~1%. We have developed a method for accurately measuring the polarization of altitude-azimuth mounted telescopes by observing bright nearby stars at different parallactic angles, and we find that the on-axis polarization of the William Herschel Telescope is typically ~15 × 10-6, measured with an accuracy of a few parts in 107. The nearby stars (distance less than 32 pc) are found to have very low polarizations, typically a few ×10-6, indicating that very little interstellar polarization is produced close to the Sun and that their intrinsic polarization is also low. Although the polarimeter can be used for a wide range of astronomy, the very high sensitivity was set by the goal of detecting the polarization signature of unresolved extrasolar planets.

  12. High-sensitivity quantitative phase microcopy (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhou, Renjie; Kuang, Cuifang; Hosseini, Poorya; Chowdhary, Ravi; Yaqoob, Zahid; So, Peter T. C.

    2016-03-01

    In the past decade, various quantitative phase microscopy (QPM) techniques have emerged, driven by the need to study biological samples non-invasively. However, the fundamental limit for phase noise is scarcely discussed in the literature. In a typically off-axis phase microscope system, the phase noise is limited to a few milliradians using a moderate camera. Common-path QPMs offer much reduced phase noise compared to typical Mach-Zehnder-based systems. However, further scaling down the phase noise becomes difficult. Here we propose a high-sensitivity common-path QPM that promises to reduce the phase noise by a factor of 10 (assuming the mechanical noise is negligible). This is achieved by a specifically designed signal filter, leaving only the subtle phase fluctuations coming from the dynamics sample scattering. By working at photon shot-noise limited detection, we can magnify the subtle phase contrast which is proportional to the camera well depth. We expect this system to have the height sensitivity similar to an atomic force microcopy, while measuring biological structures with a full field of view in a single-shot. We plan to use this system to study cell dynamics, particularly lamellipodial height fluctuations as well as stiffer cell membrane fluctuations.

  13. High-sensitivity (25-um pitch) microbolometer FPAs

    NASA Astrophysics Data System (ADS)

    Murphy, Daniel F.; Ray, Michael; Wyles, Richard; Asbrock, James F.; Lum, Nancy A.; Kennedy, Adam; Wyles, Jessica; Hewitt, C.; Graham, Glen E.; Horikiri, Tad; Anderson, John S.; Bradley, Daryl; Chin, Richard; Kostrzewa, Thomas

    2001-11-01

    RIO has achieved a significant technical breakthrough in uncooled FPAs by reducing the pixel size by a factor of two while maintaining state-of-the-art sensitivity. Raytheon has produced high-quality 320 by 240 micro bolometer FPAs with 25 micrometers pitch pixels. The 320 by 240 FPAs have a sensitivity that is comparable to micro bolometer FPAs with 50 micrometers pixels. The average NETD value for these FPAs is about 35 mK with an f/1 aperture and operating at 30 Hz frame rates. Good pixel operability and excellent image quality have been demonstrated. Pixel operability is greater than 99 percent on some FPAs, and uncorrected responsivity nonuniformity is less than 4 percent. The micro bolometer detectors also have a relatively fast thermal time constant of approximately 10 msec. This state-of-the-art performance has been achieved as a result of an advanced micromachining fabrication process. The process allows maximization of both the thermal isolation and the optical fill-factor. The reduction in pixel size offers several potential benefits for IR systems. For a given system resolution requirement, the 225 micrometers pixels allow a factor of two reduction in both the focal length and aperture size of the sensor optics. The pixel size reduction facilitates a significant FPA cost reduction since the number of die printed on a wafer can be increased. The pixel size reduction has enabled the development of a large-format 640 by 512 FPA array applicable to wide-field-of-view, long range surveillance and targeting missions, and a 160 by 128 array where applications for miniaturization and temperature invariance are required as well as low cost and low power.

  14. Reduced graphene oxide electrically contacted graphene sensor for highly sensitive nitric oxide detection.

    PubMed

    Li, Weiwei; Geng, Xiumei; Guo, Yufen; Rong, Jizan; Gong, Youpin; Wu, Liqiong; Zhang, Xuemin; Li, Peng; Xu, Jianbao; Cheng, Guosheng; Sun, Mengtao; Liu, Liwei

    2011-09-27

    We develop graphene-based devices fabricated by alternating current dielectrophoresis (ac-DEP) for highly sensitive nitric oxide (NO) gas detection. The novel device comprises the sensitive channels of palladium-decorated reduced graphene oxide (Pd-RGO) and the electrodes covered with chemical vapor deposition (CVD)-grown graphene. The highly sensitive, recoverable, and reliable detection of NO gas ranging from 2 to 420 ppb with response time of several hundred seconds has been achieved at room temperature. The facile and scalable route for high performance suggests a promising application of graphene devices toward the human exhaled NO and environmental pollutant detections. PMID:21834585

  15. Linearization strategies for high sensitivity magnetoresistive sensors

    NASA Astrophysics Data System (ADS)

    Silva, Ana V.; Leitao, Diana C.; Valadeiro, João; Amaral, José; Freitas, Paulo P.; Cardoso, Susana

    2015-10-01

    Ultrasensitive magnetic field sensors envisaged for applications on biomedical imaging require the detection of low-intensity and low-frequency signals. Therefore linear magnetic sensors with enhanced sensitivity low noise levels and improved field detection at low operating frequencies are necessary. Suitable devices can be designed using magnetoresistive sensors, with room temperature operation, adjustable detected field range, CMOS compatibility and cost-effective production. The advent of spintronics set the path to the technological revolution boosted by the storage industry, in particular by the development of read heads using magnetoresistive devices. New multilayered structures were engineered to yield devices with linear output. We present a detailed study of the key factors influencing MR sensor performance (materials, geometries and layout strategies) with focus on different linearization strategies available. Furthermore strategies to improve sensor detection levels are also addressed with best reported values of ˜40 pT/√Hz at 30 Hz, representing a step forward the low field detection at room temperature.

  16. High-speed high-sensitivity infrared spectroscopy using mid-infrared swept lasers (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Childs, David T. D.; Groom, Kristian M.; Hogg, Richard A.; Revin, Dmitry G.; Cockburn, John W.; Rehman, Ihtesham U.; Matcher, Stephen J.

    2016-03-01

    Infrared spectroscopy is a highly attractive read-out technology for compositional analysis of biomedical specimens because of its unique combination of high molecular sensitivity without the need for exogenous labels. Traditional techniques such as FTIR and Raman have suffered from comparatively low speed and sensitivity however recent innovations are challenging this situation. Direct mid-IR spectroscopy is being speeded up by innovations such as MEMS-based FTIR instruments with very high mirror speeds and supercontinuum sources producing very high sample irradiation levels. Here we explore another possible method - external cavity quantum cascade lasers (EC-QCL's) with high cavity tuning speeds (mid-IR swept lasers). Swept lasers have been heavily developed in the near-infrared where they are used for non-destructive low-coherence imaging (OCT). We adapt these concepts in two ways. Firstly by combining mid-IR quantum cascade gain chips with external cavity designs adapted from OCT we achieve spectral acquisition rates approaching 1 kHz and demonstrate potential to reach 100 kHz. Secondly we show that mid-IR swept lasers share a fundamental sensitivity advantage with near-IR OCT swept lasers. This makes them potentially able to achieve the same spectral SNR as an FTIR instrument in a time x N shorter (N being the number of spectral points) under otherwise matched conditions. This effect is demonstrated using measurements of a PDMS sample. The combination of potentially very high spectral acquisition rates, fundamental SNR advantage and the use of low-cost detector systems could make mid-IR swept lasers a powerful technology for high-throughput biomedical spectroscopy.

  17. High sensitivity real-time NVR monitor

    NASA Technical Reports Server (NTRS)

    Bowers, William D. (Inventor); Chuan, Raymond L. (Inventor)

    1997-01-01

    A real time non-volatile residue (NVR) monitor, which utilizes surface acoustic wave (SAW) resonators to detect molecular contamination in a given environment. The SAW resonators operate at a resonant frequency of approximately 200 MHz-2,000 MHz which enables the NVR monitor to detect molecular contamination on the order of 10.sup.-11 g-cm.sup.-2 to 10.sup.-13 g-cm.sup.2. The NVR monitor utilizes active temperature control of (SAW) resonators to achieve a stable resonant frequency. The temperature control system of the NVR monitor is able to directly heat and cool the SAW resonators utilizing a thermoelectric element to maintain the resonators at a present temperature independent of the environmental conditions. In order to enable the direct heating and cooling of the SAW resonators, the SAW resonators are operatively mounted to a heat sink. In one embodiment, the heat sink is located in between the SAW resonators and an electronic circuit board which contains at least a portion of the SAW control electronics. The electrical leads of the SAW resonators are connected through the heat sink to the circuit board via an electronic path which prevents inaccurate frequency measurement.

  18. Coherent Raman Scattering: Methods Towards Imaging with High Sensitivity

    NASA Astrophysics Data System (ADS)

    Bachler, Brandon Richard

    Coherent Raman spectroscopy is a powerful tool for molecular identification. For imaging applications, Raman spectroscopy techniques have offered a way of achieving endogenous chemical contrast without the need for fluorescent labeling. Increasing the sensitivity of Raman scattering microscopy is vital to performing high speed, chemically selective imaging. This thesis presents three experiments with the ultimate goal of increasing the sensitivity and quantifying limitations of different Raman techniques. The first experiment is a comparison of spontaneous and coherent Raman signal strengths under biological imaging conditions. While it is commonly stated in the literature that coherent Raman techniques provide orders of magnitude higher signal than spontaneous Raman, such a comparison has not been done under the low concentration, low excitation power conditions relevant for biological imaging. We determine a critical power above which coherent Raman methods provide higher signal and below which spontaneous Raman methods provide higher sensitivity. Contrary to what is commonly stated in the literature, spontaneous Raman can provide higher signal levels under common biological imaging conditions. The second experiment is a demonstration of the first multiplexed Raman-induced Kerr effect (BIKES) microscopy setup to date. We compare the signal-to-noise ratios between femtosecond stimulated Raman (FSRS) and RIKES for spectroscopy applications in solution and for microscopy applications with polystyrene beads. We find that for our samples, RIKES consistently provides a higher signal-to-noise ratio than FSRS for both applications. We also use RIKES microscopy to map out the distribution of cytoplasm in onion cells. Finally, a surface-enhanced Raman experiment is performed to observe and compare highly enhanced signals for spontaneous and coherent Raman spectroscopy. We use a commercial SERS substrate and observe significantly enhanced spontaneous Raman signals from

  19. The high heritability of educational achievement reflects many genetically influenced traits, not just intelligence.

    PubMed

    Krapohl, Eva; Rimfeld, Kaili; Shakeshaft, Nicholas G; Trzaskowski, Maciej; McMillan, Andrew; Pingault, Jean-Baptiste; Asbury, Kathryn; Harlaar, Nicole; Kovas, Yulia; Dale, Philip S; Plomin, Robert

    2014-10-21

    Because educational achievement at the end of compulsory schooling represents a major tipping point in life, understanding its causes and correlates is important for individual children, their families, and society. Here we identify the general ingredients of educational achievement using a multivariate design that goes beyond intelligence to consider a wide range of predictors, such as self-efficacy, personality, and behavior problems, to assess their independent and joint contributions to educational achievement. We use a genetically sensitive design to address the question of why educational achievement is so highly heritable. We focus on the results of a United Kingdom-wide examination, the General Certificate of Secondary Education (GCSE), which is administered at the end of compulsory education at age 16. GCSE scores were obtained for 13,306 twins at age 16, whom we also assessed contemporaneously on 83 scales that were condensed to nine broad psychological domains, including intelligence, self-efficacy, personality, well-being, and behavior problems. The mean of GCSE core subjects (English, mathematics, science) is more heritable (62%) than the nine predictor domains (35-58%). Each of the domains correlates significantly with GCSE results, and these correlations are largely mediated genetically. The main finding is that, although intelligence accounts for more of the heritability of GCSE than any other single domain, the other domains collectively account for about as much GCSE heritability as intelligence. Together with intelligence, these domains account for 75% of the heritability of GCSE. We conclude that the high heritability of educational achievement reflects many genetically influenced traits, not just intelligence.

  20. The high heritability of educational achievement reflects many genetically influenced traits, not just intelligence

    PubMed Central

    Krapohl, Eva; Rimfeld, Kaili; Shakeshaft, Nicholas G.; Trzaskowski, Maciej; McMillan, Andrew; Pingault, Jean-Baptiste; Asbury, Kathryn; Harlaar, Nicole; Kovas, Yulia; Dale, Philip S.; Plomin, Robert

    2014-01-01

    Because educational achievement at the end of compulsory schooling represents a major tipping point in life, understanding its causes and correlates is important for individual children, their families, and society. Here we identify the general ingredients of educational achievement using a multivariate design that goes beyond intelligence to consider a wide range of predictors, such as self-efficacy, personality, and behavior problems, to assess their independent and joint contributions to educational achievement. We use a genetically sensitive design to address the question of why educational achievement is so highly heritable. We focus on the results of a United Kingdom-wide examination, the General Certificate of Secondary Education (GCSE), which is administered at the end of compulsory education at age 16. GCSE scores were obtained for 13,306 twins at age 16, whom we also assessed contemporaneously on 83 scales that were condensed to nine broad psychological domains, including intelligence, self-efficacy, personality, well-being, and behavior problems. The mean of GCSE core subjects (English, mathematics, science) is more heritable (62%) than the nine predictor domains (35–58%). Each of the domains correlates significantly with GCSE results, and these correlations are largely mediated genetically. The main finding is that, although intelligence accounts for more of the heritability of GCSE than any other single domain, the other domains collectively account for about as much GCSE heritability as intelligence. Together with intelligence, these domains account for 75% of the heritability of GCSE. We conclude that the high heritability of educational achievement reflects many genetically influenced traits, not just intelligence. PMID:25288728

  1. Reward sensitivity: issues of measurement, and achieving consilience between human and animal phenotypes.

    PubMed

    Stephens, David N; Duka, Theodora; Crombag, Hans S; Cunningham, Christopher L; Heilig, Markus; Crabbe, John C

    2010-04-01

    Reward is a concept fundamental to discussions of drug abuse and addiction. The idea that altered sensitivity to either drug-reward, or to rewards in general, contributes to, or results from, drug-taking is a common theme in several theories of addiction. However, the concept of reward is problematic in that it is used to refer to apparently different behavioural phenomena, and even to diverse neurobiological processes (reward pathways). Whether these different phenomena are different behavioural expressions of a common underlying process is not established, and much research suggests that there may be only loose relationships among different aspects of reward. Measures of rewarding effects of drugs in humans often depend upon subjective reports. In animal studies, such insights are not available, and behavioural measures must be relied upon to infer rewarding effects of drugs or other events. In such animal studies, but also in many human methods established to objectify measures of reward, many other factors contribute to the behaviour being studied. For that reason, studying the biological (including genetic) bases of performance of tasks that ostensibly measure reward cannot provide unequivocal answers. The current overview outlines the strengths and weaknesses of current approaches that hinder the conciliation of cross-species studies of the genetics of reward sensitivity and the dysregulation of reward processes by drugs of abuse. Some suggestions are made as to how human and animal studies may be made to address more closely homologous behaviours, even if those processes are only partly able to isolate 'reward' from other factors contributing to behavioural output.

  2. Sensitivity and noise in GC-MS: Achieving low limits of detection for difficult analytes

    NASA Astrophysics Data System (ADS)

    Fialkov, Alexander B.; Steiner, Urs; Lehotay, Steven J.; Amirav, Aviv

    2007-01-01

    Gas chromatography-mass spectrometry (GC-MS) instrument limit of detection (LOD) is typically listed by major vendors as that of octafluoronaphthalene (OFN). Most current GC-MS instruments can achieve LODs in the low femtogram range. However, GC-MS LODs for realistic analytes in actual samples are often a few orders of magnitude higher than OFN's. Users seldom encounter 1 pg LOD in the single ion monitoring mode in their applications. We define this detectability difference as the "OFN gap." In this paper, we demonstrate and discuss how the OFN gap can be significantly reduced by the use of GC-MS with supersonic molecular beams (SMB). Experimental results were obtained with a recently developed GC-MS with SMB named 1200-SMB, that is based on the conversion of the Varian 1200 system into a GC-MS-MS with SMB. With this 1200-SMB system, the LOD of all types of analytes, including OFN, in real samples is significantly improved through the combination of: (a) enhanced molecular ion; (b) elimination of vacuum background noise; (c) elimination of mass independent noise; (d) elimination of ion source peak tailing and degradation; (e) significantly increased range of thermally labile and low volatility compounds that are amenable for analysis through lower sample elution temperatures; (f) reduced column bleed and ghost peaks through sample elution at lower temperatures; (g) improved compatibility with large volume injections; and (h) reduced matrix interferences through the combination of enhanced molecular ion and MS-MS. As a result, the 1200-SMB LODs of common and/or difficult compounds are much closer to its OFN LOD, even in complex matrices. We crossed the <1 fg OFN LOD milestone to achieve the lowest LOD to date using GC-MS, but more importantly, we attained LOD of 2 fg for diazinon, a common pesticide analyte. In another example, we achieved an LOD of 10 fg for underivatized testosterone, which is not amenable in traditional GC-MS analysis, and conducted many analyses

  3. Relationship between High School Mathematical Achievement and Quantitative GPA

    ERIC Educational Resources Information Center

    Brown, Jennifer L.; Halpin, Glennelle; Halpin, Gerald

    2015-01-01

    The demand for STEM graduates has increased, but the number of incoming freshmen who declare a STEM major has remained stagnant. High school courses, such as calculus, can open or close the gate for students interested in careers in STEM. The purpose of this study was to determine if high school mathematics preparation was a significant…

  4. Relationships among Stress, Coping, and Mental Health in High-Achieving High School Students

    ERIC Educational Resources Information Center

    Suldo, Shannon M.; Shaunessy, Elizabeth; Hardesty, Robin

    2008-01-01

    This study investigates the relationships among stress, coping, and mental health in 139 students participating in an International Baccalaureate (IB) high school diploma program. Mental health was assessed using both positive indicators (life satisfaction, academic achievement, academic self-efficacy) and negative indicators (psychopathology) of…

  5. The Information Search Process of High-, Middle-, and Low-Achieving High School Seniors.

    ERIC Educational Resources Information Center

    Kuhlthau, Carol C.

    1989-01-01

    Presents a model of the information search process as a complex series of stages involving thoughts and feelings as well as actions. A study that sought to verify the model using high school seniors from three different achievement levels is described, and the implications for library instruction are discussed. (five references) (CLB)

  6. The Strengths of High-Achieving Black High School Students in a Racially Diverse Setting

    ERIC Educational Resources Information Center

    Marsh, Kris; Chaney, Cassandra; Jones, Derrick

    2012-01-01

    Robert Hill (1972) identified strengths of Black families: strong kinship bonds, strong work orientation, adaptability of family roles, high achievement orientation, and religious orientation. Some suggest these strengths sustain the physical, emotional, social, and spiritual needs of Blacks. This study used narratives and survey data from a…

  7. Examining Organizational Practices That Predict Persistence among High-Achieving Black Males in High School

    ERIC Educational Resources Information Center

    Anderson, Kenneth Alonzo

    2016-01-01

    Background/Context: This article summarizes an increasing trend of antideficit Black male research in mathematics and highlights opportunities to add to the research. A review of the literature shows that antideficit researchers often examine relationships between individual traits and persistence of high-achieving Black males in mathematics.…

  8. High-sensitivity strain sensor based on inflated long period fiber grating.

    PubMed

    Zhong, Xiaoyong; Wang, Yiping; Qu, Junle; Liao, Changrui; Liu, Shen; Tang, Jian; Wang, Qiao; Zhao, Jing; Yang, Kaiming; Li, Zhengyong

    2014-09-15

    We demonstrated a high-sensitivity strain sensor based on an inflated long period fiber grating (I-LPFG). The I-LPFG was inscribed, for the first time to the best of our knowledge, by use of the pressure-assisted CO(2) laser beam scanning technique to inflate periodically air holes of a photonic crystal fiber. Such periodic inflations enhanced the sensitivity of the LPFG-based strain sensor to -5.62 pm/με. After high temperature annealing, the I-LPFG achieved a good repeatability and stability of temperature response with a sensitivity of 11.92 pm/°C. PMID:26466298

  9. Achieving effective terminal exciton delivery in quantum dot antenna-sensitized multistep DNA photonic wires.

    PubMed

    Spillmann, Christopher M; Ancona, Mario G; Buckhout-White, Susan; Algar, W Russ; Stewart, Michael H; Susumu, Kimihiro; Huston, Alan L; Goldman, Ellen R; Medintz, Igor L

    2013-08-27

    Assembling DNA-based photonic wires around semiconductor quantum dots (QDs) creates optically active hybrid architectures that exploit the unique properties of both components. DNA hybridization allows positioning of multiple, carefully arranged fluorophores that can engage in sequential energy transfer steps while the QDs provide a superior energy harvesting antenna capacity that drives a Förster resonance energy transfer (FRET) cascade through the structures. Although the first generation of these composites demonstrated four-sequential energy transfer steps across a distance >150 Å, the exciton transfer efficiency reaching the final, terminal dye was estimated to be only ~0.7% with no concomitant sensitized emission observed. Had the terminal Cy7 dye utilized in that construct provided a sensitized emission, we estimate that this would have equated to an overall end-to-end ET efficiency of ≤ 0.1%. In this report, we demonstrate that overall energy flow through a second generation hybrid architecture can be significantly improved by reengineering four key aspects of the composite structure: (1) making the initial DNA modification chemistry smaller and more facile to implement, (2) optimizing donor-acceptor dye pairings, (3) varying donor-acceptor dye spacing as a function of the Förster distance R0, and (4) increasing the number of DNA wires displayed around each central QD donor. These cumulative changes lead to a 2 orders of magnitude improvement in the exciton transfer efficiency to the final terminal dye in comparison to the first-generation construct. The overall end-to-end efficiency through the optimized, five-fluorophore/four-step cascaded energy transfer system now approaches 10%. The results are analyzed using Förster theory with various sources of randomness accounted for by averaging over ensembles of modeled constructs. Fits to the spectra suggest near-ideal behavior when the photonic wires have two sequential acceptor dyes (Cy3 and Cy3.5) and

  10. Japanese High School Entrance Examinations and Scholastic Achievement.

    ERIC Educational Resources Information Center

    Togashi, Yutaka

    1985-01-01

    The Japanese high school entrance examinations were examined in detail for social studies, mathematics, and science test items. Most items measured knowledge and comprehension rather than synthesis, analysis, or scientific thinking. Implications for middle school instruction were discussed. (GDC)

  11. Practically Perfect in Every Way: Can Reframing Perfectionism for High-Achieving Undergraduates Impact Academic Resilience?

    ERIC Educational Resources Information Center

    Dickinson, Mary J.; Dickinson, David A. G.

    2015-01-01

    This study focuses on a pan-disciplinary scheme that targeted high-achieving undergraduate students. Earlier research from the scheme argued that high achievers have discernibly different learning and personal development support needs. One of the most frequent self-reported challenges within this high-achieving group is perfectionism. This…

  12. A batteryless temperature sensor based on high temperature sensitive material

    NASA Astrophysics Data System (ADS)

    Bakkali, Asma; Pelegri-Sebastia, José; Laghmich, Youssef; Lyhyaoui, Abdelouahid

    2016-05-01

    The major challenge in wireless sensor networks is the reduction of energy consumption. Passive wireless sensor network is an attractive solution for measuring physical parameters in harsh environment for large range of applications requiring sensing devices with low cost of fabrication, small size and long term measurement stability. Batteryless temperature sensing techniques are an active research field. The approach developed in our work holds a promising future for temperature sensor applications in order to successfully reduce the energy consumption. The temperature sensor presented in this paper is based on the electromagnetic transduction principle using the integration of the high temperature sensitive material into a passive structure. Variation in temperature makes the dielectric constant of this material changing, and such modification induces variation in the resonant frequencies of high-Q whispering-gallery modes (WGM) in the millimeter-wave frequency range. Following the results achieved, the proposed device shows a linear response to the increasing temperature and these variations can be remotely detected from a radar interrogation. Contribution to the topical issue "Materials for Energy Harvesting, Conversion and Storage (ICOME 2015) - Elected submissions", edited by Jean-Michel Nunzi, Rachid Bennacer and Mohammed El Ganaoui

  13. Achieving high-value cardiac imaging: challenges and opportunities.

    PubMed

    Wiener, David H

    2014-01-01

    Cardiac imaging is under intense scrutiny as a contributor to health care costs, with multiple initiatives under way to reduce and eliminate inappropriate testing. Appropriate use criteria are valuable guides to selecting imaging studies but until recently have focused on the test rather than the patient. Patient-centered means are needed to define the true value of imaging for patients in specific clinical situations. This article provides a definition of high-value cardiac imaging. A paradigm to judge the efficacy of echocardiography in the absence of randomized controlled trials is presented. Candidate clinical scenarios are proposed in which echocardiography constitutes high-value imaging, as well as stratagems to increase the likelihood that high-value cardiac imaging takes place in those circumstances.

  14. High temperature probe sensor with high sensitivity based on Michelson interferometer

    NASA Astrophysics Data System (ADS)

    Zhao, Na; Fu, Haiwei; Shao, Min; Yan, Xu; Li, Huidong; Liu, Qinpeng; Gao, Hong; Liu, Yinggang; Qiao, Xueguang

    2015-05-01

    A novel Michelson interferometer based on a bi-taper is achieved. Such a device is fabricated by splicing a section of thin core fiber (TCF) at one end of single-mode fiber (SMF). Due to the fiber bi-taper at the splicing point of SMF and TCF, the light is coupled into the fiber core and cladding from lead in fiber core. The light will be reflected at the end of the fiber and then will be recoupled back into the lead out fiber core by the fiber bi-taper. While the light returns back to the lead out fiber, the intermodal interference will occur for the optical path difference between core mode and cladding mode. A high temperature sensitivity of 0.140 nm/°C is achieved from 30 to 800 °C, and the linearity is 99.9%. The configuration features the advantages of easy fabrication, a compact size, high sensitivity, wide sensing range and high mechanical strength, making it a good candidate for distant temperature sensing and oil prospecting.

  15. Achieving high CRI from warm to super white

    NASA Astrophysics Data System (ADS)

    Bailey, Edward; Tormey, Ellen S.

    2007-09-01

    Light sources which produce a high color rendering index (CRI) have many applications in the lighting industry today. High color rendering accents the rich color which abounds in nature, interior design, theatrical costumes and props, clothing and fabric, jewelry, and machine vision applications. Multi-wavelength LED sources can pump phosphors at multiple stokes shift emission regimes and when combined with selected direct emission sources can allow for greater flexibility in the production of warm-white and cool white light of specialty interest. Unique solutions to R8 and R14 CRI >95 at 2850K, 4750K, 5250K, and 6750K presented.

  16. Community Schools Seek to Improve High School Achievement, College Readiness

    ERIC Educational Resources Information Center

    Gilroy, Marilyn

    2011-01-01

    The Coalition for Community Schools, an alliance of more than 150 national, state, and local organizations, is bringing public schools in partnership with community resources to improve student success. While that might seem like an abstract idea, it has very concrete goals, such as boosting high school graduation rates and college readiness.…

  17. High-Achieving Schools Put Equity Front and Center

    ERIC Educational Resources Information Center

    Gleason, Sonia Caus; Gerzon, Nancy

    2014-01-01

    How does professional learning look and feel in high-poverty schools where every student makes at least one year's worth of progress every year? How do schools and leaders put all the varied components of professional learning together so that they support all students learning every day? What professional learning grounds and sustains…

  18. Organizational Citizenship of Faculty and Achievement of High School Students

    ERIC Educational Resources Information Center

    DiPaola, Michael F.; Hoy, Wayne K.

    2005-01-01

    All successful organizations, including successful high schools, have employees who go beyond their formal job responsibilities and freely give of their time and energy to succeed. Organ was the first to use the phrase "organizational citizenship behavior" (OCB) to denote organizationally beneficial behavior of workers that was not prescribed but…

  19. Academic Dishonesty among Gifted and High-Achieving Students

    ERIC Educational Resources Information Center

    Geddes, Kimberly A.

    2011-01-01

    Gifted high school students are essentially absent in the research concerning academic integrity; however, over the past few years, educators of gifted students have noticed an increase in the occurrences of academic dishonesty among students in gifted classrooms (Abilock, 2009). This research may be analyzed to provide some insight into the…

  20. Vocational Interests of Intellectually Gifted and Highly Achieving Young Adults

    ERIC Educational Resources Information Center

    Vock, Miriam; Koller, Olaf; Nagy, Gabriel

    2013-01-01

    Background: Vocational interests play a central role in the vocational decision-making process and are decisive for the later job satisfaction and vocational success. Based on Ackerman's (1996) notion of "trait complexes," specific interest profiles of gifted high-school graduates can be expected. Aims: Vocational interests of gifted and highly…

  1. Common Core and America's High-Achieving Students

    ERIC Educational Resources Information Center

    Plucker, Jonathan A.

    2015-01-01

    While the merit and politics of the Common Core State Standards (CCSS) have been much debated and discussed, one topic has been virtually ignored: What do the standards portend for America's high-ability students? This brief addresses that question and provides guidance for CCSS-implementing districts and schools as they seek to help these…

  2. The Relationship between Highly Qualified Teachers and Student Academic Achievement

    ERIC Educational Resources Information Center

    Macken, Sherry Lou

    2013-01-01

    This study examined the relationship between the percentage of highly qualified teachers and standardized measures of student proficiency in the core academic subjects of mathematics, reading, science, social studies, and writing. Signed into law in January of 2002 by President George W. Bush, the No Child Left Behind (NCLB) Act requires teachers…

  3. More High-Achieving Students Are Choosing Community Colleges First

    ERIC Educational Resources Information Center

    Pluviose, David

    2008-01-01

    Certainly, "Tonight Show" host Jay Leno has nurtured the perception that community colleges are a punishment for underperforming high school students by joking that community colleges aren't "real colleges." This article shows that this perception belies the reality that contemporary community colleges serve students seeking trade skills but also…

  4. Park View High School: A World of Achievement

    ERIC Educational Resources Information Center

    Principal Leadership, 2010

    2010-01-01

    Entering the lobby of Park View High School in Sterling, VA, is like entering another world. The diversity in the student body is reflected in flags from 63 of the 80 countries that are represented in the student population, and in a special project for Hispanic Heritage Month, which covers the walls of an entire hallway. The school walls,…

  5. Testing Theories of Learning: Effects on High School Achievement.

    ERIC Educational Resources Information Center

    Keith, Timothy Z.; Cool, Valerie A.

    Theories of school learning consistently point to variables such as ability, time (e.g., homework), quality of instruction, motivation, and academic coursework as important influences on learning. In this study, path analysis was used to test the direct and indirect effects of these variables on high school learning, with learning measured by both…

  6. Gender, Student Motivation and Academic Achievement in a Midsized Wisconsin High School

    ERIC Educational Resources Information Center

    Lutzke, Steven Ronald

    2013-01-01

    This mixed-methods study investigated relationships among gender, academic motivation and achievement in a mid-sized Wisconsin high school. A questionnaire was developed that focused on perceived ability, achievement motives and achievement goals. Interviews with teachers focused on relationships among academic motivation and gender achievement.…

  7. Impact of learning orientation on African American children's attitudes toward high-achieving peers.

    PubMed

    Marryshow, Derrick; Hurley, Eric A; Allen, Brenda A; Tyler, Kenneth M; Boykin, A Wade

    2005-01-01

    This study examined Ogbu's widely accepted thesis that African American students reject high academic achievement because they perceive its limited utility in a world where their upward mobility is constrained by racial discrimination. Boykin's psychosocial integrity model contends that Black students value high achievement but that discrepancies between their formative cultural experiences and those imposed in school lead them to reject the modes of achievement available in classrooms. Ninety Black children completed a measure of attitudes toward students who achieve via mainstream or African American cultural values. Participants rejected the mainstream achievers and embraced the African American cultural achievers. Moreover, they expected their teachers to embrace the mainstream achievers and reject those who achieved through high-verve behavior. Results suggest that Boykin's thesis is a needed refinement to Ogbu's ideas. They indicate that Black children may reject not high achievement but some of the mainstream cultural values and behaviors on which success in mainstream classrooms is made contingent.

  8. Principals’ Perception of Influence on Factors Affecting Student Achievement in Low- and High-Achieving Urban High Schools

    ERIC Educational Resources Information Center

    Bloom, Collette M.; Owens, Emiel W.

    2013-01-01

    The purpose of the study was to compare and contrast influences principals have on staffing, curriculum issues, and discipline policies in high- and low-performing urban high schools. The data for the present study were drawn from the first year follow up of the Educational Longitudinal Survey of 2002-2004 (ELS: 02), administered by the National…

  9. Achievement of a 920-MHz High Resolution NMR

    NASA Astrophysics Data System (ADS)

    Hashi, Kenjiro; Shimizu, Tadashi; Goto, Atsushi; Kiyoshi, Tsukasa; Matsumoto, Shinji; Wada, Hitoshi; Fujito, Teruaki; Hasegawa, Ken-ichi; Yoshikawa, Masatoshi; Miki, Takashi; Ito, Satoshi; Hamada, Mamoru; Hayashi, Seiji

    2002-06-01

    We have developed a 920-MHz NMR system and performed the proton NMR measurement of H 2O and ethylbenzene using the superconducting magnet operating at 21.6 T (920 MHz for proton), which is the highest field produced by a superconducting NMR magnet in the persistent mode. From the NMR measurements, it is verified that both homogeneity and stability of the magnet have a specification sufficient for a high resolution NMR.

  10. Telescoping Solar Array Concept for Achieving High Packaging Efficiency

    NASA Technical Reports Server (NTRS)

    Mikulas, Martin; Pappa, Richard; Warren, Jay; Rose, Geoff

    2015-01-01

    Lightweight, high-efficiency solar arrays are required for future deep space missions using high-power Solar Electric Propulsion (SEP). Structural performance metrics for state-of-the art 30-50 kW flexible blanket arrays recently demonstrated in ground tests are approximately 40 kW/cu m packaging efficiency, 150 W/kg specific power, 0.1 Hz deployed stiffness, and 0.2 g deployed strength. Much larger arrays with up to a megawatt or more of power and improved packaging and specific power are of interest to mission planners for minimizing launch and life cycle costs of Mars exploration. A new concept referred to as the Compact Telescoping Array (CTA) with 60 kW/cu m packaging efficiency at 1 MW of power is described herein. Performance metrics as a function of array size and corresponding power level are derived analytically and validated by finite element analysis. Feasible CTA packaging and deployment approaches are also described. The CTA was developed, in part, to serve as a NASA reference solar array concept against which other proposed designs of 50-1000 kW arrays for future high-power SEP missions could be compared.

  11. Efforts toward achieving an unmanned, high-altitude LTA platform

    SciTech Connect

    Onda, Masahiko; Ford, M.L.

    1996-10-01

    The modern demands for an unmanned aerospace platform, capable of long-duration stationkeeping at high-altitudes, are well-known. Satellites, balloons, and aircraft have traditionally served in the role of platform, facilitating tasks ranging from telecommunications to deep-space astronomy. However, limitations on the performance and flexibility of these systems, as well as the intrinsically high-cost of satellite construction, operation, and repair, warrants development of a supplemental technology for the platform. Much has been written in the literature on the possible advantages of a lighter-than-air (LTA) platform, if such an LTA could be constructed. Potential applications include remote sensing, environmental monitoring, mobile communications, space and polar observations, cargo delivery, military reconnaissance, and others. At present, conventional LTA`s are not capable of serving in the manner specified. Within this context, a research program known as HALROP (High Altitude Long Range Observational Platform) is currently underway. The goal is to create a stratospheric platform, possibly in the form of a next generation LTA vehicle. The authors present a qualitative review of their efforts, focusing on milestones in the HALROP Program. 12 refs., 6 figs., 2 tabs.

  12. Achieving High Reliability Operations Through Multi-Program Integration

    SciTech Connect

    Holly M. Ashley; Ronald K. Farris; Robert E. Richards

    2009-04-01

    Over the last 20 years the Idaho National Laboratory (INL) has adopted a number of operations and safety-related programs which has each periodically taken its turn in the limelight. As new programs have come along there has been natural competition for resources, focus and commitment. In the last few years, the INL has made real progress in integrating all these programs and are starting to realize important synergies. Contributing to this integration are both collaborative individuals and an emerging shared vision and goal of the INL fully maturing in its high reliability operations. This goal is so powerful because the concept of high reliability operations (and the resulting organizations) is a masterful amalgam and orchestrator of the best of all the participating programs (i.e. conduct of operations, behavior based safety, human performance, voluntary protection, quality assurance, and integrated safety management). This paper is a brief recounting of the lessons learned, thus far, at the INL in bringing previously competing programs into harmony under the goal (umbrella) of seeking to perform regularly as a high reliability organization. In addition to a brief diagram-illustrated historical review, the authors will share the INL’s primary successes (things already effectively stopped or started) and the gaps yet to be bridged.

  13. Introducing wet aerosols into the static high sensitivity ICP (SHIP).

    PubMed

    Scheffer, Andy; Engelhard, Carsten; Sperling, Michael; Buscher, Wolfgang

    2007-08-01

    A demountable design of the static high sensitivity ICP (SHIP) for optical emission spectrometry is presented, and its use as an excitation source with the introduction of wet aerosols was investigated. Aerosols were produced by standard pneumatic sample introduction systems, namely a cross flow nebulizer, Meinhard nebulizer and PFA low flow nebulizer, which have been applied in conjunction with a double pass and a cyclonic spray chamber. The analytical capabilities of these sample introduction systems in combination with the SHIP system were evaluated with respect to the achieved sensitivity. It was found that a nebulizer tailored for low argon flow rates (0.3-0.5 L min(-1)) is best suited for the low flow plasma (SHIP). An optimization of all gas flow rates of the SHIP system with the PFA low flow nebulizer was carried out in a two-dimensional way with the signal to background ratio (SBR) and the robustness as optimization target parameters. Optimum conditions for a torch model with 1-mm injector tube were 0.25 and 0.36 L min(-1) for the plasma gas and the nebulizer gas, respectively. A torch model with a 2-mm injector tube was optimized to 0.4 L min(-1) for the plasma gas and 0.44 L min(-1) for the nebulizer gas. In both cases the SHIP system saves approximately 95% of the argon consumed by conventional inductively coupled plasma systems. The limits of detection were found to be in the low microgram per litre range and below for many elements, which was quite comparable to those of the conventional setup. Furthermore, the short-term stability and the wash out behaviour of the SHIP were investigated. Direct comparison with the conventional setup indicated that no remarkable memory effects were caused by the closed design of the torch. The analysis of a NIST SRM 1643e (Trace Elements in Water) with the SHIP yielded recoveries of 97-103% for 13 elements, measured simultaneously.

  14. Single nanobeam optical sensor with a high Q-factor and high sensitivity.

    PubMed

    Kim, Sejeong; Kim, Hwi-Min; Lee, Yong-Hee

    2015-11-15

    The miniaturization of optical sensors is essential for the realization of compact, portable, and cost-effective devices. Photonic crystal-based optical sensors, which have an ultra-small mode volume and footprint, have demonstrated remarkable recent progress in achieving a high figure-of-merit (FOM) in a sensor. Here, we report an optical sensor with a high Q-factor and high sensitivity based on a photonic crystal nanobeam using the second lowest air band-edge mode. We calculated that a nanobeam (n=3.4) in a water environment (n=1.33) has refractive-index sensitivity of ~631 nm/RIU, while the quality factor is greater than 23,300. Accordingly, a theoretical FOM of the sensor corresponds to >9500. To the best of our knowledge, experimental refractive-index sensitivity of 461 nm/RIU is the highest value among photonic crystal single nanobeam geometry. The simple geometry of uniform air hole sizes and lattice constants in the proposed nanobeam sensor allows easy fabrication and mechanical stability. PMID:26565872

  15. Advancing Minority High Achievement: National Trends and Promising Programs and Practices. A Report Prepared for the National Task Force on Minority High Achievement, the College Board.

    ERIC Educational Resources Information Center

    Borman, Geoffrey D.; Stringfield, Sam; Rachuba, Laura

    This report documents recent national progress in advancing the achievements of elementary-aged minority children, the potential for replicable whole-school reform designs to contribute to this advancement, and the individual, classroom, and school characteristics that distinguish those minority students who attain high levels of achievement. The…

  16. Optimization of X-ray phase contrast imaging system toward high-sensitivity measurements of biological organs

    SciTech Connect

    Hoshino, Masato; Uesugi, Kentaro; Yagi, Naoto

    2012-07-31

    X-ray phase contrast imaging and tomography using a Talbot grating interferometer is currently available for user experiments at BL20B2 in SPring-8. The measurement condition for X-ray phase contrast tomography has been optimized to achieve high-sensitivity measurements of biological soft tissues and organs. Some biological samples were measured to demonstrate the high-sensitivity imaging.

  17. The Relationship between Parental Involvement and Student Achievement in a Rural Florida High School

    ERIC Educational Resources Information Center

    Jackson, Willie A.

    2011-01-01

    Parental involvement is viewed as critical to the development of effective schools and student achievement. The relationship between parental involvement and achievement test scores at a rural high school in Florida was not known. This high school has not met the state standards as determined by the Florida Comprehensive Achievement Test (FCAT)…

  18. High Achievement in Mathematics Education in India: A Report from Mumbai

    ERIC Educational Resources Information Center

    Raman, Manya

    2010-01-01

    This paper reports a study aimed at characterizing the conditions that lead to high achievement in mathematics in India. The study involved eight schools in the greater Mumbai region. The main result of the study is that the notion of high achievement itself is problematic, as reflected in the reports about mathematics achievement within and…

  19. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity

    NASA Astrophysics Data System (ADS)

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  20. Design optimization of high pressure and high temperature piezoresistive pressure sensor for high sensitivity.

    PubMed

    Niu, Zhe; Zhao, Yulong; Tian, Bian

    2014-01-01

    This paper describes a design method for optimizing sensitivity of piezoresistive pressure sensor in high-pressure and high-temperature environment. In order to prove the method, a piezoresistive pressure sensor (HPTSS) is designed. With the purpose of increasing sensitivity and to improve the measurement range, the piezoresistive sensor adopts rectangular membrane and thick film structure. The configuration of piezoresistors is arranged according to the characteristic of the rectangular membrane. The structure and configuration of the sensor chip are analyzed theoretically and simulated by the finite element method. This design enables the sensor chip to operate in high pressure condition (such as 150 MPa) with a high sensitivity and accuracy. The silicon on insulator wafer is selected to guarantee the thermo stability of the sensor chip. In order to optimize the fabrication and improve the yield of production, an electric conduction step is devised. Series of experiments demonstrates a favorable linearity of 0.13% and a high accuracy of 0.48%. And the sensitivity of HTPSS is about six times as high as a conventional square-membrane sensor chip in the experiment. Compared with the square-membrane pressure sensor and current production, the strength of HPTTS lies in sensitivity and measurement. The performance of the HPTSS indicates that it could be an ideal candidate for high-pressure and high-temperature sensing in real application.

  1. Predicting delay in reading achievement in a highly transparent language.

    PubMed

    Holopainen, L; Ahonen, T; Lyytinen, H

    2001-01-01

    A random sample of 91 preschool children was assessed prior to receiving formal reading instruction. Verbal and nonverbal measures were used as predictors for the time of instruction required to accurately decode pseudowords in the highly orthographically regular Finnish language. After 2 years, participants were divided into four groups depending on the duration of instruction they had required to reach 90 % accuracy in their reading of pseudowords. Participants were classified as precocious decoders (PD), who could read at school entry; early decoders (ED), who learned to read within the first 4 months of Grade 1; ordinary decoders (OD), who learned to read within 9 months; and late decoders (LD), who failed to reach the criterion after 18 months of reading instruction at Grade 2. Phonological awareness played a significant role only in differentiating PD from ED and OD. However, phonological awareness failed to predict the delayed learning process of LD. LD differed from all other groups in visual analogical reasoning in an analysis not containing phonological awareness measures. Letter knowledge and visual analogical reasoning explained above 90% of the PD-LD difference. Preschool composite (objects, colors, and digits) naming speed measures best predicted reading fluency at the end of Grade 2. The supportive role of orthographic knowledge in phonological awareness, the role of visual analogical reasoning, and the inability of phonological measures to discriminate late decoders are discussed.

  2. Achieving High-Frequency Optical Control of Synaptic Transmission

    PubMed Central

    Jackman, Skyler L.; Beneduce, Brandon M.; Drew, Iain R.

    2014-01-01

    The optogenetic tool channelrhodopsin-2 (ChR2) is widely used to excite neurons to study neural circuits. Previous optogenetic studies of synapses suggest that light-evoked synaptic responses often exhibit artificial synaptic depression, which has been attributed to either the inability of ChR2 to reliably fire presynaptic axons or to ChR2 elevating the probability of release by depolarizing presynaptic boutons. Here, we compare light-evoked and electrically evoked synaptic responses for high-frequency stimulation at three synapses in the mouse brain. At synapses from Purkinje cells to deep cerebellar nuclei neurons (PC→DCN), light- and electrically evoked synaptic currents were remarkably similar for ChR2 expressed transgenically or with adeno-associated virus (AAV) expression vectors. For hippocampal CA3→CA1 synapses, AAV expression vectors of serotype 1, 5, and 8 led to light-evoked synaptic currents that depressed much more than electrically evoked currents, even though ChR2 could fire axons reliably at up to 50 Hz. The disparity between optical and electrical stimulation was eliminated when ChR2 was expressed transgenically or with AAV9. For cerebellar granule cell to stellate cell (grc→SC) synapses, AAV1 also led to artificial synaptic depression and AAV9 provided superior performance. Artificial synaptic depression also occurred when stimulating over presynaptic boutons, rather than axons, at CA3→CA1 synapses, but not at PC→DCN synapses. These findings indicate that ChR2 expression methods and light stimulation techniques influence synaptic responses in a neuron-specific manner. They also identify pitfalls associated with using ChR2 to study synapses and suggest an approach that allows optogenetics to be applied in a manner that helps to avoid potential complications. PMID:24872574

  3. A high-sensitivity neutron counter and waste-drum counting with the high-sensitivity neutron instrument

    SciTech Connect

    Hankins, D.E.; Thorngate, J.H.

    1993-04-01

    At Lawrence Livermore National Laboratory (LLNL), a highly sensitive neutron counter was developed that can detect and accurately measure the neutrons from small quantities of plutonium or from other low-level neutron sources. This neutron counter was originally designed to survey waste containers leaving the Plutonium Facility. However, it has proven to be useful in other research applications requiring a high-sensitivity neutron instrument.

  4. Highly sensitive and reconfigurable fiber optic current sensor by optical recirculating in a fiber loop.

    PubMed

    Du, Jiangbing; Tao, Yemeng; Liu, Yinping; Ma, Lin; Zhang, Wenjia; He, Zuyuan

    2016-08-01

    An advanced fiber optic current sensor (FOCS) is proposed based on recirculating fiber loop architecture for significantly enhancing the current sensitivity. The recirculating loop is constructed by a 2X2 optical switch and the standard single mode fiber (SSMF) is used as the sensing head. The proposed FOCS is coupler-free with low insertion loss which results in a significantly improved current sensitivity. We experimentally obtained a sensitivity of 11.5 degrees/A for 1-Km SSMF FOCS and a sensitivity of 21.2 degrees/A for 500-m SSMF FOCS, both of which have been enhanced by more than ten times. The flexible switch control of recirculating can support the FOCS to work for different current scenarios with the same system and thus reconfigurable operation of the FOCS has been achieved. The significantly enhanced high sensitivity with reconfigurable operation capability makes the proposed FOCS a promising method for practical applications. PMID:27505765

  5. The Chinese High School Student's Stress in the School and Academic Achievement

    ERIC Educational Resources Information Center

    Liu, Yangyang; Lu, Zuhong

    2011-01-01

    In a sample of 466 Chinese high school students, we examined the relationships between Chinese high school students' stress in the school and their academic achievements. Regression mixture modelling identified two different classes of the effects of Chinese high school students' stress on their academic achievements. One class contained 87% of…

  6. The Effects of Magnet Schools on Neighborhood High Schools: An Examination of Achievement among Entering Freshmen

    ERIC Educational Resources Information Center

    Neild, Ruth Curran

    2004-01-01

    Magnet schools have been criticized for intensifying the concentration of disadvantaged, low-achieving students at neighborhood high schools. This article investigates the impact of academically selective magnet high schools on the average achievement of ninth graders enrolling in neighborhood high schools in a large urban school district. The…

  7. Beyond Academic Reputation: Factors that Influence the College of First Choice for High Achieving Students

    ERIC Educational Resources Information Center

    Schoenherr, Holly J.

    2009-01-01

    Studies that have investigated college choice factors for high-achieving students repeatedly cite academic reputation as one of the top indicators of choice but have not indicated why some high-achieving students choose to attend universities with a less prestigious reputation than the more highly prestigious options available to them. The purpose…

  8. Preferred Homework Style and Homework Environment in High- versus Low-Achieving Chinese Students.

    ERIC Educational Resources Information Center

    Hong, Eunsook; Lee, Kit-hung

    This study compared preferred homework styles of Chinese students who were characterized by: (1) high versus low self-perceived homework achievement and attitude; (2) high versus low teacher-rated homework completion and quality; (3) high versus low academic achievement in mathematics. Gender differences in homework styles were also examined.…

  9. A COMPREHENSIVE STUDY OF THE MOTIVATIONAL FACTORS UNDERLYING ACHIEVEMENT OF ELEVENTH-GRADE HIGH SCHOOL STUDENTS.

    ERIC Educational Resources Information Center

    FARQUHAR, WILLIAM W.

    ACHIEVEMENT MOTIVATION WAS STUDIED BETWEEN OVER- AND UNDER-ACHIEVING STUDENTS IN THE ELEVENTH-GRADE TO DEVELOP AN OBJECTIVE MEASURE OF MOTIVATION FOR USE IN PREDICTING ACADEMIC SUCCESS OR FAILURE. APPROXIMATELY 800 STUDENTS IN PUBLIC HIGH SCHOOLS WERE SELECTED FOR VALIDATION AND CROSS-VALIDATION SAMPLES. THEY WERE DIVIDED BY SEX AND ACHIEVEMENT.…

  10. Does High School Facility Quality Affect Student Achievement? A Two-Level Hierarchical Linear Model

    ERIC Educational Resources Information Center

    Bowers, Alex J.; Urick, Angela

    2011-01-01

    The purpose of this study is to isolate the independent effects of high school facility quality on student achievement using a large, nationally representative U.S. database of student achievement and school facility quality. Prior research on linking school facility quality to student achievement has been mixed. Studies that relate overall…

  11. The Effects of Web-Based/Non-Web-Based Problem-Solving Instruction and High/Low Achievement on Students' Problem-Solving Ability and Biology Achievement

    ERIC Educational Resources Information Center

    Yu, Wen-Feng; She, Hsiao-Ching; Lee, Yu-Mei

    2010-01-01

    This study investigates the effects of two factors: the mode of problem-solving instruction (i.e. Web-based versus non-Web-based) and the level of academic achievement (i.e. high achievers versus low achievers) on students' problem-solving ability and biology achievement. A quasi-experimental design was used, in which the experimental group…

  12. A Hybrid LPG/CFBG for Highly Sensitive Refractive Index Measurements

    PubMed Central

    Sun, An; Wu, Zhishen

    2012-01-01

    A simple and high sensitive method employing a hybrid long period grating (LPG)/chirped fiber Bragg grating (CFBG) for refractive index (RI) measurements is proposed and investigated experimentally. The wide wavelength range of backward cladding modes are excited through the coupling and recoupling between LPG and CFBG. Experimental results indicate that the recoupled cladding modes between LPG and CFBG and core mode are modulated by the surrounding RI and highly sensitive RI measurements can be achieved by simply measuring the reflected intensity changes of the recoupled cladding modes and core mode. PMID:22969347

  13. Design of a High Sensitivity GNSS receiver for Lunar missions

    NASA Astrophysics Data System (ADS)

    Musumeci, Luciano; Dovis, Fabio; Silva, João S.; da Silva, Pedro F.; Lopes, Hugo D.

    2016-06-01

    This paper presents the design of a satellite navigation receiver architecture tailored for future Lunar exploration missions, demonstrating the feasibility of using Global Navigation Satellite Systems signals integrated with an orbital filter to achieve such a scope. It analyzes the performance of a navigation solution based on pseudorange and pseudorange rate measurements, generated through the processing of very weak signals of the Global Positioning System (GPS) L1/L5 and Galileo E1/E5 frequency bands. In critical scenarios (e.g. during manoeuvres) acceleration and attitude measurements from additional sensors complementing the GNSS measurements are integrated with the GNSS measurement to match the positioning requirement. A review of environment characteristics (dynamics, geometry and signal power) for the different phases of a reference Lunar mission is provided, focusing on the stringent requirements of the Descent, Approach and Hazard Detection and Avoidance phase. The design of High Sensitivity acquisition and tracking schemes is supported by an extensive simulation test campaign using a software receiver implementation and navigation results are validated by means of an end-to-end software simulator. Acquisition and tracking of GPS and Galileo signals of the L1/E1 and L5/E5a bands was successfully demonstrated for Carrier-to-Noise density ratios as low as 5-8 dB-Hz. The proposed navigation architecture provides acceptable performances during the considered critical phases, granting position and velocity errors below 61.4 m and 3.2 m/s, respectively, for the 99.7% of the mission time.

  14. Near-infrared squaraine co-sensitizer for high-efficiency dye-sensitized solar cells.

    PubMed

    Rao, G Hanumantha; Venkateswararao, A; Giribabu, L; Han, Liyuan; Bedja, Idriss; Gupta, Ravindra Kumar; Islam, Ashraful; Singh, Surya Prakash

    2016-06-01

    A combination of squaraine-based dyes (SPSQ1 and SPSQ2) and a ruthenium-based dye (N3) were chosen as co-sensitizers to construct efficient dye-sensitized solar cells. The co-sensitization of squaraine dyes with N3 enhanced their light-harvesting properties as a result of the broad spectral coverage in the region 350-800 nm. The co-sensitized solar cells based on SPSQ2 + N3 showed the highest short circuit current density of 17.10 mA cm(-2), an open circuit voltage of 0.66 V and a fill factor of 0.73, resulting in the highest power conversion efficiency of 8.2%, which is higher than that of the dye-sensitized solar cells based on the individual SPSQ1 and SPSQ2 dyes. The high power conversion efficiency of SPSQ2 + N3 was ascribed to its good light-harvesting properties, which resulted from its broader incident photon current conversion spectrum than that of the individual dyes. The high electron life time and electron recombination, which were the main causes of the higher efficiency of the device, were successfully analysed and correlated using transient absorption spectrometry and intensity-modulated photovoltage spectrometry.

  15. Highly sensitive tactile sensors integrated with organic transistors

    NASA Astrophysics Data System (ADS)

    Kim, Jiseok; Nga Ng, Tse; Soo Kim, Woo

    2012-09-01

    This paper presents a highly sensitive capacitive pressure sensor composed of a polymer dielectric film with a nano-needle structure. The nano-needle polymer films were prepared by facile fabrication methods including breath figures formation followed by stamping. The pressure sensitivity of the sensor reached 1.76 kPa-1 in the low pressure range (<1 kPa), which is comparable to the sensitivity of human skin. Analysis of the geometries and densities effect was shown, and the nano-needle film showed better sensitivity in comparison to films with hemispherical or conical structures. The pressure sensors were integrated with printed organic thin film transistors to enable flexible, large-area tactile sensing applications.

  16. An Analysis of Java Programming Behaviors, Affect, Perceptions, and Syntax Errors among Low-Achieving, Average, and High-Achieving Novice Programmers

    ERIC Educational Resources Information Center

    Rodrigo, Ma. Mercedes T.; Andallaza, Thor Collin S.; Castro, Francisco Enrique Vicente G.; Armenta, Marc Lester V.; Dy, Thomas T.; Jadud, Matthew C.

    2013-01-01

    In this article we quantitatively and qualitatively analyze a sample of novice programmer compilation log data, exploring whether (or how) low-achieving, average, and high-achieving students vary in their grasp of these introductory concepts. High-achieving students self-reported having the easiest time learning the introductory programming…

  17. Highly sensitive bovine serum albumin biosensor based on liquid crystal

    NASA Astrophysics Data System (ADS)

    Sharma, Vikash; Kumar, Ajay; Ganguly, Prasun; Biradar, A. M.

    2014-01-01

    A highly sensitive liquid crystal (LC) based bovine serum albumin (BSA) protein biosensor is designed. A uniform homeotropic alignment of nematic LC was observed in BSA free substrate which changed into homogeneous in presence of BSA. The change in the LC orientation is found to depend strongly on BSA concentration. This change in the LC alignment is attributed to the modification in the surface conditions which is verified by contact angle measurements. We have detected an ultra low concentration (0.5 μg/ml) of BSA. The present study demonstrates the utilization of LC in the realization of high sensitivity biosensors.

  18. High-speed asynchronous optical sampling for high-sensitivity detection of coherent phonons

    NASA Astrophysics Data System (ADS)

    Dekorsy, T.; Taubert, R.; Hudert, F.; Schrenk, G.; Bartels, A.; Cerna, R.; Kotaidis, V.; Plech, A.; Köhler, K.; Schmitz, J.; Wagner, J.

    2007-12-01

    A new optical pump-probe technique is implemented for the investigation of coherent acoustic phonon dynamics in the GHz to THz frequency range which is based on two asynchronously linked femtosecond lasers. Asynchronous optical sampling (ASOPS) provides the performance of on all-optical oscilloscope and allows us to record optically induced lattice dynamics over nanosecond times with femtosecond resolution at scan rates of 10 kHz without any moving part in the set-up. Within 1 minute of data acquisition time signal-to-noise ratios better than 107 are achieved. We present examples of the high-sensitivity detection of coherent phonons in superlattices and of the coherent acoustic vibration of metallic nanoparticles.

  19. High-sensitivity in situ QCLAS-based ammonia concentration sensor for high-temperature applications

    NASA Astrophysics Data System (ADS)

    Peng, W. Y.; Sur, R.; Strand, C. L.; Spearrin, R. M.; Jeffries, J. B.; Hanson, R. K.

    2016-07-01

    A novel quantum cascade laser (QCL) absorption sensor is presented for high-sensitivity in situ measurements of ammonia (hbox {NH}_3) in high-temperature environments, using scanned wavelength modulation spectroscopy (WMS) with first-harmonic-normalized second-harmonic detection (scanned WMS-2 f/1 f) to neutralize the effect of non-absorption losses in the harsh environment. The sensor utilized the sQ(9,9) transition of the fundamental symmetric stretch band of hbox {NH}_3 at 10.39 {\\upmu }hbox {m} and was sinusoidally modulated at 10 kHz and scanned across the peak of the absorption feature at 50 Hz, leading to a detection bandwidth of 100 Hz. A novel technique was used to select an optimal WMS modulation depth parameter that reduced the sensor's sensitivity to spectral interference from hbox {H}_2hbox {O} and hbox {CO}_2 without significantly sacrificing signal-to-noise ratio. The sensor performance was validated by measuring known concentrations of hbox {NH}_3 in a flowing gas cell. The sensor was then demonstrated in a laboratory-scale methane-air burner seeded with hbox {NH}_3, achieving a demonstrated detection limit of 2.8 ± 0.26 ppm hbox {NH}_3 by mole at a path length of 179 cm, equivalence ratio of 0.6, pressure of 1 atm, and temperatures of up to 600 K.

  20. International Note: Between-Domain Relations of Chinese High School Students' Academic Achievements

    ERIC Educational Resources Information Center

    Yangyang, Liu

    2012-01-01

    The present study examined the between-domain relations of Chinese high school students' academic achievements. In a sample of 1870 Chinese 10th grade students, the results indicated that Chinese high school students' academic achievements were correlated across nine subjects. In line with the previous Western findings, the findings suggested that…

  1. The Effect of the Time Management Art on Academic Achievement among High School Students in Jordan

    ERIC Educational Resources Information Center

    Al-Zoubi, Maysoon

    2016-01-01

    This study aimed at recognizing the effect of the Time Management Art on academic achievement among high school students in the Hashemite Kingdom of Jordan. The researcher employed the descriptive-analytic research to achieve the purpose of the study where he chose a sample of (2000) high school female and male students as respondents to the…

  2. High-Achieving and Average Students' Reading Growth: Contrasting School and Summer Trajectories

    ERIC Educational Resources Information Center

    Rambo-Hernandez, Karen E.; McCoach, D. Betsy

    2015-01-01

    Much is unknown about how initially high-achieving students grow academically, especially given the measurement issues inherent in assessing growth for the highest performing students. This study compared initially high-achieving and average students' growth in reading (in a cohort of third-grade students from 2,000 schools) over 3 years.…

  3. A Longitudinal Investigation of Project-Based Instruction and Student Achievement in High School Social Studies

    ERIC Educational Resources Information Center

    Summers, Emily J.; Dickinson, Gail

    2012-01-01

    This longitudinal study focused on how project-based instruction (PBI) influenced secondary social studies students' academic achievement and promoted College and Career Readiness (CCR). We explored and compared student achievement in a PBI high school versus a traditional instruction high school within the same rural school district. While…

  4. High-sensitivity, high-speed continuous imaging system

    DOEpatents

    Watson, Scott A; Bender, III, Howard A

    2014-11-18

    A continuous imaging system for recording low levels of light typically extending over small distances with high-frame rates and with a large number of frames is described. Photodiode pixels disposed in an array having a chosen geometry, each pixel having a dedicated amplifier, analog-to-digital convertor, and memory, provide parallel operation of the system. When combined with a plurality of scintillators responsive to a selected source of radiation, in a scintillator array, the light from each scintillator being directed to a single corresponding photodiode in close proximity or lens-coupled thereto, embodiments of the present imaging system may provide images of x-ray, gamma ray, proton, and neutron sources with high efficiency.

  5. A low-power, high-sensitivity micromachined optical magnetometer

    NASA Astrophysics Data System (ADS)

    Mhaskar, R.; Knappe, S.; Kitching, J.

    2012-12-01

    We demonstrate an optical magnetometer based on a microfabricated 87Rb vapor cell in a micromachined silicon sensor head. The alkali atom density in the vapor cell is increased by heating the cell with light brought to the sensor through an optical fiber, and absorbed by colored filters attached to the cell windows. A second fiber-optically coupled beam optically pumps and interrogates the atoms. The magnetometer operates on 140 mW of heating power and achieves a sensitivity below 20 fT/√Hz throughout most of the frequency band from 15 Hz to 100 Hz. Such a sensor can measure magnetic fields from the human heart and brain.

  6. The Meaning High-Achieving African-American Males in an Urban High School Ascribe to Mathematics

    ERIC Educational Resources Information Center

    Thompson, LaTasha; Davis, Julius

    2013-01-01

    Many researchers, educators, administrators, policymakers and members of the general public doubt the prevalence of high-achieving African-American males in urban high schools capable of excelling in mathematics. As part of a larger study, the current study explored the educational experiences of four high-achieving African-American males…

  7. A highly sensitive CMOS digital Hall sensor for low magnetic field applications.

    PubMed

    Xu, Yue; Pan, Hong-Bin; He, Shu-Zhuan; Li, Li

    2012-01-01

    Integrated CMOS Hall sensors have been widely used to measure magnetic fields. However, they are difficult to work with in a low magnetic field environment due to their low sensitivity and large offset. This paper describes a highly sensitive digital Hall sensor fabricated in 0.18 μm high voltage CMOS technology for low field applications. The sensor consists of a switched cross-shaped Hall plate and a novel signal conditioner. It effectively eliminates offset and low frequency 1/f noise by applying a dynamic quadrature offset cancellation technique. The measured results show the optimal Hall plate achieves a high current related sensitivity of about 310 V/AT. The whole sensor has a remarkable ability to measure a minimum ± 2 mT magnetic field and output a digital Hall signal in a wide temperature range from -40 °C to 120 °C.

  8. A Highly Sensitive CMOS Digital Hall Sensor for Low Magnetic Field Applications

    PubMed Central

    Xu, Yue; Pan, Hong-Bin; He, Shu-Zhuan; Li, Li

    2012-01-01

    Integrated CMOS Hall sensors have been widely used to measure magnetic fields. However, they are difficult to work with in a low magnetic field environment due to their low sensitivity and large offset. This paper describes a highly sensitive digital Hall sensor fabricated in 0.18 μm high voltage CMOS technology for low field applications. The sensor consists of a switched cross-shaped Hall plate and a novel signal conditioner. It effectively eliminates offset and low frequency 1/f noise by applying a dynamic quadrature offset cancellation technique. The measured results show the optimal Hall plate achieves a high current related sensitivity of about 310 V/AT. The whole sensor has a remarkable ability to measure a minimum ±2 mT magnetic field and output a digital Hall signal in a wide temperature range from −40 °C to 120 °C. PMID:22438758

  9. High-Sensitivity X-ray Polarimetry with Amorphous Silicon Active-Matrix Pixel Proportional Counters

    NASA Technical Reports Server (NTRS)

    Black, J. K.; Deines-Jones, P.; Jahoda, K.; Ready, S. E.; Street, R. A.

    2003-01-01

    Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout

  10. Sensitivity of high-frequency Rayleigh-wave data revisited

    USGS Publications Warehouse

    Xia, J.; Miller, R.D.; Ivanov, J.

    2007-01-01

    Rayleigh-wave phase velocity of a layered earth model is a function of frequency and four groups of earth properties: P-wave velocity, S-wave velocity (Vs), density, and thickness of layers. Analysis of the Jacobian matrix (or the difference method) provides a measure of dispersion curve sensitivity to earth properties. Vs is the dominant influence for the fundamental mode (Xia et al., 1999) and higher modes (Xia et al., 2003) of dispersion curves in a high frequency range (>2 Hz) followed by layer thickness. These characteristics are the foundation of determining S-wave velocities by inversion of Rayleigh-wave data. More applications of surface-wave techniques show an anomalous velocity layer such as a high-velocity layer (HVL) or a low-velocity layer (LVL) commonly exists in near-surface materials. Spatial location (depth) of an anomalous layer is usually the most important information that surface-wave techniques are asked to provide. Understanding and correctly defining the sensitivity of high-frequency Rayleigh-wave data due to depth of an anomalous velocity layer are crucial in applying surface-wave techniques to obtain a Vs profile and/or determine the depth of an anomalous layer. Because depth is not a direct earth property of a layered model, changes in depth will result in changes in other properties. Modeling results show that sensitivity at a given depth calculated by the difference method is dependent on the Vs difference (contrast) between an anomalous layer and surrounding layers. The larger the contrast is, the higher the sensitivity due to depth of the layer. Therefore, the Vs contrast is a dominant contributor to sensitivity of Rayleigh-wave data due to depth of an anomalous layer. Modeling results also suggest that the most sensitive depth for an HVL is at about the middle of the depth to the half-space, but for an LVL it is near the ground surface. ?? 2007 Society of Exploration Geophysicists.

  11. Nature's crucible: Manufacturing optical nonlinearities for high resolution, high sensitivity encoding in the compound eye of the fly, Musca domestica

    NASA Technical Reports Server (NTRS)

    Wilcox, Mike

    1993-01-01

    The number of pixels per unit area sampling an image determines Nyquist resolution. Therefore, the highest pixel density is the goal. Unfortunately, as reduction in pixel size approaches the wavelength of light, sensitivity is lost and noise increases. Animals face the same problems and have achieved novel solutions. Emulating these solutions offers potentially unlimited sensitivity with detector size approaching the diffraction limit. Once an image is 'captured', cellular preprocessing of information allows extraction of high resolution information from the scene. Computer simulation of this system promises hyperacuity for machine vision.

  12. Highly Mass-Sensitive Thin Film Plate Acoustic Resonators (FPAR)

    PubMed Central

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D.; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented. PMID:22163994

  13. Highly mass-sensitive thin film plate acoustic resonators (FPAR).

    PubMed

    Arapan, Lilia; Alexieva, Gergana; Avramov, Ivan D; Radeva, Ekaterina; Strashilov, Vesseline; Katardjiev, Ilia; Yantchev, Ventsislav

    2011-01-01

    The mass sensitivity of thin aluminum nitride (AlN) film S0 Lamb wave resonators is theoretically and experimentally studied. Theoretical predictions based on modal and finite elements method analysis are experimentally verified. Here, two-port 888 MHz synchronous FPARs are micromachined and subsequently coated with hexamethyl-disiloxane(HMDSO)-plasma-polymerized thin films of various thicknesses. Systematic data on frequency shift and insertion loss versus film thickness are presented. FPARs demonstrate high mass-loading sensitivity as well as good tolerance towards the HMDSO viscous losses. Initial measurements in gas phase environment are further presented.

  14. Porous silicon ring resonator for compact, high sensitivity biosensing applications

    DOE PAGES

    Rodriguez, Gilberto A.; Hu, Shuren; Weiss, Sharon M.

    2015-01-01

    A ring resonator is patterned on a porous silicon slab waveguide to produce a compact, high quality factor biosensor with a large internal surface area available for enhanced recognition of biological and chemical molecules. The porous nature of the ring resonator allows molecules to directly interact with the guided mode. Quality factors near 10,000 were measured for porous silicon ring resonators with a radius of 25 μm. A bulk detection sensitivity of 380 nm/RIU was measured upon exposure to salt water solutions. Specific detection of nucleic acid molecules was demonstrated with a surface detection sensitivity of 4 pm/nM.

  15. The Achievement of Therapeutic Objectives Scale: Interrater Reliability and Sensitivity to Change in Short-Term Dynamic Psychotherapy and Cognitive Therapy

    ERIC Educational Resources Information Center

    Valen, Jakob; Ryum, Truls; Svartberg, Martin; Stiles, Tore C.; McCullough, Leigh

    2011-01-01

    This study examined interrater reliability and sensitivity to change of the Achievement of Therapeutic Objectives Scale (ATOS; McCullough, Larsen, et al., 2003) in short-term dynamic psychotherapy (STDP) and cognitive therapy (CT). The ATOS is a process scale originally developed to assess patients' achievements of treatment objectives in STDP,…

  16. Achieving high strength and high ductility in magnesium alloy using hard-plate rolling (HPR) process.

    PubMed

    Wang, Hui-Yuan; Yu, Zhao-Peng; Zhang, Lei; Liu, Chun-Guo; Zha, Min; Wang, Cheng; Jiang, Qi-Chuan

    2015-01-01

    Magnesium alloys are highly desirable for a wide range of lightweight structural components. However, rolling Mg alloys can be difficult due to their poor plasticity, and the strong texture yielded from rolling often results in poor plate forming ability, which limits their further engineering applications. Here we report a new hard-plate rolling (HPR) route which achieves a large reduction during a single rolling pass. The Mg-9Al-1Zn (AZ91) plates processed by HPR consist of coarse grains of 30-60 μm, exhibiting a typical basal texture, fine grains of 1-5 μm and ultrafine (sub) grains of 200-500 nm, both of the latter two having a weakened texture. More importantly, the HPR was efficient in gaining a simultaneous high strength and uniform ductility, i.e., ~371 MPa and ~23%, respectively. The superior properties should be mainly attributed to the cooperation effect of the multimodal grain structure and weakened texture, where the former facilitates a strong work hardening while the latter promotes the basal slip. The HPR methodology is facile and effective, and can avoid plate cracking that is prone to occur during conventional rolling processes. This strategy is applicable to hard-to-deform materials like Mg alloys, and thus has a promising prospect for industrial application. PMID:26603776

  17. Lipid target achievement among patients with very high and high cardiovascular risk in a lipid clinic.

    PubMed

    Barkas, Fotios; Liberopoulos, Evangelos N; Kostapanos, Michael S; Liamis, George; Tziallas, Dimitrios; Elisaf, Moses

    2015-04-01

    This was a retrospective study that assessed achievement of lipid-lowering treatment targets in the setting of a University Hospital Lipid Clinic. Low-density lipoprotein cholesterol (LDL-C) goal attainment according to National Cholesterol Education Program-Adult Treatment Panel III (NCEP ATP III) and European Society of Cardiology/European Atherosclerosis Society (ESC/EAS) guidelines was recorded in 1000 consecutive adult patients followed for ≥3 years (mean 8 years). The LDL-C targets according to the NCEP ATP III were attained by 66% and 86% of patients with "very high" (n = 477) and "high" (n = 408) cardiovascular risk, respectively. Fewer patients were within LDL-C goals according to the ESC/EAS guidelines: 25% and 42%. Overall, 92% of the patients were on statins: 67% were on statin monotherapy, while 33% were on combinations with ezetimibe (25%), ω-3 fatty acids (5%), fibrates (4%), or colesevelam (2%). Even in a specialist lipid clinic, a large proportion of patients are not at goal according to the recent ESC/EAS guidelines. PMID:24830420

  18. Achieving high strength and high ductility in magnesium alloy using hard-plate rolling (HPR) process.

    PubMed

    Wang, Hui-Yuan; Yu, Zhao-Peng; Zhang, Lei; Liu, Chun-Guo; Zha, Min; Wang, Cheng; Jiang, Qi-Chuan

    2015-11-25

    Magnesium alloys are highly desirable for a wide range of lightweight structural components. However, rolling Mg alloys can be difficult due to their poor plasticity, and the strong texture yielded from rolling often results in poor plate forming ability, which limits their further engineering applications. Here we report a new hard-plate rolling (HPR) route which achieves a large reduction during a single rolling pass. The Mg-9Al-1Zn (AZ91) plates processed by HPR consist of coarse grains of 30-60 μm, exhibiting a typical basal texture, fine grains of 1-5 μm and ultrafine (sub) grains of 200-500 nm, both of the latter two having a weakened texture. More importantly, the HPR was efficient in gaining a simultaneous high strength and uniform ductility, i.e., ~371 MPa and ~23%, respectively. The superior properties should be mainly attributed to the cooperation effect of the multimodal grain structure and weakened texture, where the former facilitates a strong work hardening while the latter promotes the basal slip. The HPR methodology is facile and effective, and can avoid plate cracking that is prone to occur during conventional rolling processes. This strategy is applicable to hard-to-deform materials like Mg alloys, and thus has a promising prospect for industrial application.

  19. Achieving high strength and high ductility in magnesium alloy using hard-plate rolling (HPR) process

    PubMed Central

    Wang, Hui–Yuan; Yu, Zhao–Peng; Zhang, Lei; Liu, Chun–Guo; Zha, Min; Wang, Cheng; Jiang, Qi–Chuan

    2015-01-01

    Magnesium alloys are highly desirable for a wide range of lightweight structural components. However, rolling Mg alloys can be difficult due to their poor plasticity, and the strong texture yielded from rolling often results in poor plate forming ability, which limits their further engineering applications. Here we report a new hard-plate rolling (HPR) route which achieves a large reduction during a single rolling pass. The Mg-9Al-1Zn (AZ91) plates processed by HPR consist of coarse grains of 30–60 μm, exhibiting a typical basal texture, fine grains of 1–5 μm and ultrafine (sub) grains of 200–500 nm, both of the latter two having a weakened texture. More importantly, the HPR was efficient in gaining a simultaneous high strength and uniform ductility, i.e., ~371 MPa and ~23%, respectively. The superior properties should be mainly attributed to the cooperation effect of the multimodal grain structure and weakened texture, where the former facilitates a strong work hardening while the latter promotes the basal slip. The HPR methodology is facile and effective, and can avoid plate cracking that is prone to occur during conventional rolling processes. This strategy is applicable to hard-to-deform materials like Mg alloys, and thus has a promising prospect for industrial application. PMID:26603776

  20. Integrated compact optical current sensors with high sensitivity

    NASA Astrophysics Data System (ADS)

    Huang, Duanni; Pintus, Paolo; Srinivasan, Sudharsanan; Bowers, John E.

    2016-02-01

    We demonstrate a Sagnac based fiber optic current sensor using only 10cm of terbium doped fiber with a high Verdet constant of 15.5 rad/Tm at a wavelength of 1300nm. Measurements of the fiber inside a solenoid show over 40dB of open loop dynamic range as well as a minimum detectable current of 0.1mA. In order to decrease size while increasing sensitivity even further, we consider integrated magneto-optic waveguides as the sensing element. Using silicon waveguides alongside magneto-optic material such as cerium doped yttrium iron garnet (Ce:YiG), we model the Verdet constant to be as high as 10,000 rad/Tm. This improvement by three orders of magnitude shows potential for magnetooptic waveguides to be used in ultra-high sensitivity optical magnetometers and current sensors. Finally, we propose a fully integrated optical current sensor using heterogeneous integration for silicon photonics.

  1. High-sensitivity linear piezoresistive transduction for nanomechanical beam resonators.

    PubMed

    Sansa, Marc; Fernández-Regúlez, Marta; Llobet, Jordi; San Paulo, Álvaro; Pérez-Murano, Francesc

    2014-01-01

    Highly sensitive conversion of motion into readable electrical signals is a crucial and challenging issue for nanomechanical resonators. Efficient transduction is particularly difficult to realize in devices of low dimensionality, such as beam resonators based on carbon nanotubes or silicon nanowires, where mechanical vibrations combine very high frequencies with miniscule amplitudes. Here we describe an enhanced piezoresistive transduction mechanism based on the asymmetry of the beam shape at rest. We show that this mechanism enables highly sensitive linear detection of the vibration of low-resistivity silicon beams without the need of exceptionally large piezoresistive coefficients. The general application of this effect is demonstrated by detecting multiple-order modes of silicon nanowire resonators made by either top-down or bottom-up fabrication methods. These results reveal a promising approach for practical applications of the simplest mechanical resonators, facilitating its manufacturability by very large-scale integration technologies. PMID:25000256

  2. A novel high-sensitivity FBG pressure sensor

    NASA Astrophysics Data System (ADS)

    Yao, Zhenhua; Fu, Tao; Leng, Jinsong

    2007-07-01

    A novel pressure sensor based on FBG is designed in this paper. Not only in normal environment, also does it accurately work in water and petrol where other conventional sensors can not work normally. In this paper, the principle of the novel sensor is introduced, and two experiments are further performed: One is keeping the sensor flatly in the gastight silo whose pressure is supplied by an air compressing engine, and the other one is keeping the sensor in liquid. The analysis of the result data demonstrates that the sensor possesses high sensitivity, high linearity, high precision and repeatability. Its experimental linearity and sensitivity approach 0.99858 and 5.35×10 -3MPa -1, respectively. It is also discussed using the sensor to measure the volume in tank.

  3. High-sensitivity linear piezoresistive transduction for nanomechanical beam resonators.

    PubMed

    Sansa, Marc; Fernández-Regúlez, Marta; Llobet, Jordi; San Paulo, Álvaro; Pérez-Murano, Francesc

    2014-01-01

    Highly sensitive conversion of motion into readable electrical signals is a crucial and challenging issue for nanomechanical resonators. Efficient transduction is particularly difficult to realize in devices of low dimensionality, such as beam resonators based on carbon nanotubes or silicon nanowires, where mechanical vibrations combine very high frequencies with miniscule amplitudes. Here we describe an enhanced piezoresistive transduction mechanism based on the asymmetry of the beam shape at rest. We show that this mechanism enables highly sensitive linear detection of the vibration of low-resistivity silicon beams without the need of exceptionally large piezoresistive coefficients. The general application of this effect is demonstrated by detecting multiple-order modes of silicon nanowire resonators made by either top-down or bottom-up fabrication methods. These results reveal a promising approach for practical applications of the simplest mechanical resonators, facilitating its manufacturability by very large-scale integration technologies.

  4. Sensitivity of HAWC to high-mass dark matter annihilations

    NASA Astrophysics Data System (ADS)

    Abeysekara, A. U.; Alfaro, R.; Alvarez, C.; Álvarez, J. D.; Arceo, R.; Arteaga-Velázquez, J. C.; Ayala Solares, H. A.; Barber, A. S.; Baughman, B. M.; Bautista-Elivar, N.; Becerra Gonzalez, J.; Belmont, E.; BenZvi, S. Y.; Berley, D.; Bonilla Rosales, M.; Braun, J.; Caballero-Lopez, R. A.; Caballero-Mora, K. S.; Carramiñana, A.; Castillo, M.; Cotti, U.; Cotzomi, J.; de la Fuente, E.; De León, C.; DeYoung, T.; Diaz Hernandez, R.; Diaz-Cruz, L.; Díaz-Vélez, J. C.; Dingus, B. L.; DuVernois, M. A.; Ellsworth, R. W.; Fiorino, D. W.; Fraija, N.; Galindo, A.; Garfias, F.; González, M. M.; Goodman, J. A.; Grabski, V.; Gussert, M.; Hampel-Arias, Z.; Harding, J. P.; Hui, C. M.; Hüntemeyer, P.; Imran, A.; Iriarte, A.; Karn, P.; Kieda, D.; Kunde, G. J.; Lara, A.; Lauer, R. J.; Lee, W. H.; Lennarz, D.; León Vargas, H.; Linares, E. C.; Linnemann, J. T.; Longo, M.; Luna-Garcia, R.; Marinelli, A.; Martinez, H.; Martinez, O.; Martínez-Castro, J.; Matthews, J. A. J.; McEnery, J.; Mendoza Torres, E.; Miranda-Romagnoli, P.; Moreno, E.; Mostafá, M.; Nellen, L.; Newbold, M.; Noriega-Papaqui, R.; Oceguera-Becerra, T.; Patricelli, B.; Pelayo, R.; Pérez-Pérez, E. G.; Pretz, J.; Rivière, C.; Rosa-González, D.; Ryan, J.; Salazar, H.; Salesa, F.; Sanchez, F. E.; Sandoval, A.; Schneider, M.; Silich, S.; Sinnis, G.; Smith, A. J.; Sparks Woodle, K.; Springer, R. W.; Taboada, I.; Toale, P. A.; Tollefson, K.; Torres, I.; Ukwatta, T. N.; Villaseñor, L.; Weisgarber, T.; Westerhoff, S.; Wisher, I. G.; Wood, J.; Yodh, G. B.; Younk, P. W.; Zaborov, D.; Zepeda, A.; Zhou, H.; Abazajian, K. N.; Milagro Collaboration

    2014-12-01

    The High Altitude Water Cherenkov (HAWC) observatory is a wide field-of-view detector sensitive to gamma rays of 100 GeV to a few hundred TeV. Located in central Mexico at 19° North latitude and 4100 m above sea level, HAWC will observe gamma rays and cosmic rays with an array of water Cherenkov detectors. The full HAWC array is scheduled to be operational in Spring 2015. In this paper, we study the HAWC sensitivity to the gamma-ray signatures of high-mass (multi-TeV) dark matter annihilation. The HAWC observatory will be sensitive to diverse searches for dark matter annihilation, including annihilation from extended dark matter sources, the diffuse gamma-ray emission from dark matter annihilation, and gamma-ray emission from nonluminous dark matter subhalos. Here we consider the HAWC sensitivity to a subset of these sources, including dwarf galaxies, the M31 galaxy, the Virgo cluster, and the Galactic center. We simulate the HAWC response to gamma rays from these sources in several well-motivated dark matter annihilation channels. If no gamma-ray excess is observed, we show the limits HAWC can place on the dark matter cross section from these sources. In particular, in the case of dark matter annihilation into gauge bosons, HAWC will be able to detect a narrow range of dark matter masses to cross sections below thermal. HAWC should also be sensitive to nonthermal cross sections for masses up to nearly 1000 TeV. The constraints placed by HAWC on the dark matter cross section from known sources should be competitive with current limits in the mass range where HAWC has similar sensitivity. HAWC can additionally explore higher dark matter masses than are currently constrained.

  5. Proposed helmet PET geometries with add-on detectors for high sensitivity brain imaging

    NASA Astrophysics Data System (ADS)

    Tashima, Hideaki; Yamaya, Taiga

    2016-10-01

    For dedicated brain PET, we can significantly improve sensitivity for the cerebrum region by arranging detectors in a compact hemisphere. The geometrical sensitivity for the top region of the hemisphere is increased compared with conventional cylindrical PET consisting of the same number of detectors. However, the geometrical sensitivity at the center region of the hemisphere is still low because the bottom edge of the field-of-view is open, the same as for the cylindrical PET. In this paper, we proposed a helmet PET with add-on detectors for high sensitivity brain PET imaging for both center and top regions. The key point is the add-on detectors covering some portion of the spherical surface in addition to the hemisphere. As the location of the add-on detectors, we proposed three choices: a chin detector, ear detectors, and a neck detector. For example, the geometrical sensitivity for the region-of-interest at the center was increased by 200% by adding the chin detector which increased the size by 12% of the size of the hemisphere detector. The other add-on detectors gave almost the same increased sensitivity effect as the chin detector did. Compared with standard whole-body-cylindrical PET, the proposed geometries can achieve 2.6 times higher sensitivity for brain region even with less than 1/4 detectors. In addition, we conducted imaging simulations for geometries with a diameter of 250 mm and with high resolution depth-of-interaction detectors. The simulation results showed that the proposed geometries increased image quality, and all of the add-on detectors were equivalently effective. In conclusion, the proposed geometries have high potential for widespread applications in high-sensitivity, high-resolution, and low-cost brain PET imaging.

  6. Crocodylus niloticus (Crocodilia) is highly sensitive to water surface waves.

    PubMed

    Grap, Nadja J; Monzel, Anna S; Kohl, Tobias; Bleckmann, Horst

    2015-10-01

    Crocodiles show oriented responses to water surface wave stimuli but up to now behavioral thresholds are missing. This study determines the behavioral thresholds of crocodilians to water surface waves. Nile crocodiles (Crocodylus niloticus) were conditioned to respond to single-frequency water surface wave stimuli (duration 1150 ms, frequency 15, 30, 40, 60 and 80 Hz), produced by blowing air onto the water surface. Our study shows that C. niloticus is highly sensitive to capillary water surface waves. Threshold values decreased with increasing frequency and ranged between 10.3 μm (15 Hz) and 0.5 μm (80 Hz) peak-to-peak wave amplitude. For the frequencies 15 Hz and 30 Hz the sensitivity of one spectacled caiman (Caiman crocodilus) to water surface waves was also tested. Threshold values were 12.8 μm (15 Hz) down to 1.76 μm (30 Hz), i.e. close to the threshold values of C. niloticus. The surface wave sensitivity of crocodiles is similar to the surface wave sensitivity of semi-aquatic insects and fishing spiders but does not match the sensitivity of surface-feeding fishes which is higher by one to two orders of magnitude.

  7. Crocodylus niloticus (Crocodilia) is highly sensitive to water surface waves.

    PubMed

    Grap, Nadja J; Monzel, Anna S; Kohl, Tobias; Bleckmann, Horst

    2015-10-01

    Crocodiles show oriented responses to water surface wave stimuli but up to now behavioral thresholds are missing. This study determines the behavioral thresholds of crocodilians to water surface waves. Nile crocodiles (Crocodylus niloticus) were conditioned to respond to single-frequency water surface wave stimuli (duration 1150 ms, frequency 15, 30, 40, 60 and 80 Hz), produced by blowing air onto the water surface. Our study shows that C. niloticus is highly sensitive to capillary water surface waves. Threshold values decreased with increasing frequency and ranged between 10.3 μm (15 Hz) and 0.5 μm (80 Hz) peak-to-peak wave amplitude. For the frequencies 15 Hz and 30 Hz the sensitivity of one spectacled caiman (Caiman crocodilus) to water surface waves was also tested. Threshold values were 12.8 μm (15 Hz) down to 1.76 μm (30 Hz), i.e. close to the threshold values of C. niloticus. The surface wave sensitivity of crocodiles is similar to the surface wave sensitivity of semi-aquatic insects and fishing spiders but does not match the sensitivity of surface-feeding fishes which is higher by one to two orders of magnitude. PMID:26153334

  8. Decreased latent inhibition is associated with increased creative achievement in high-functioning individuals.

    PubMed

    Carson, Shelley H; Peterson, Jordan B; Higgins, Daniel M

    2003-09-01

    Reductions in latent inhibition (LI), the capacity to screen from conscious awareness stimuli previously experienced as irrelevant, have been generally associated with the tendency towards psychosis. However, "failure" to screen out previously irrelevant stimuli might also hypothetically contribute to original thinking, particularly in combination with high IQ. Meta-analysis of two studies, conducted on youthful high-IQ samples. demonstrated that high lifetime creative achievers had significantly lower LI scores than low creative achievers (r(effect size) = .31, p = .0003, one-tailed). Eminent creative achievers (participants under 21 years who reported unusually high scores in a single domain of creative achievement) were 7 times more likely to have low rather than high LI scores, chi2 (1, N = 25) = 10.69, phi = .47. p = .003.

  9. Understanding and Reversing Underachievement, Low Achievement, and Achievement Gaps among High-Ability African American Males in Urban School Contexts

    ERIC Educational Resources Information Center

    Ford, Donna Y.; Moore, James L., III

    2013-01-01

    This article focuses on the achievement gap, with attention devoted to underachievement and low achievement among African American males in urban school contexts. More specifically, the article explains problems and issues facing or confronting these Black male students in urban education settings. A central part of this discussion is grounded in…

  10. Instructional, Transformational, and Managerial Leadership and Student Achievement: High School Principals Make a Difference

    ERIC Educational Resources Information Center

    Valentine, Jerry W.; Prater, Mike

    2011-01-01

    This statewide study examined the relationships between principal managerial, instructional, and transformational leadership and student achievement in public high schools. Differences in student achievement were found when schools were grouped according to principal leadership factors. Principal leadership behaviors promoting instructional and…

  11. Low and High Mathematics Achievement in Japanese, Chinese, and American Elementary-School Children.

    ERIC Educational Resources Information Center

    Uttal, David H.; And Others

    1988-01-01

    First and fifth grade students who scored high or low on a mathematics test were tested for intellectual ability and reading achievement. Students and their mothers were interviewed. Results indicated that factors associated with levels of achievement in mathematics operate in a similar fashion across three cultures that differ greatly in their…

  12. Accelerated Mathematics and High-Ability Students' Math Achievement in Grades Three and Four

    ERIC Educational Resources Information Center

    Stanley, Ashley M.

    2011-01-01

    The purpose of this study was to explore the relationship between the use of a computer-managed integrated learning system entitled Accelerated Math (AM) as a supplement to traditional mathematics instruction on achievement as measured by TerraNova achievement tests of third and fourth grade high-ability students. Gender, socioeconomic status, and…

  13. A Quantitative Comparison of Pennsylvania High School Student Achievement by Middle States Association's Accreditation Status

    ERIC Educational Resources Information Center

    Johnson, Christopher A.

    2012-01-01

    As public school accountability for student achievement has continued to increase, prior to and as a result of the No Child Left Behind Act of 2001, schools have sought ways of bringing new instructional services to their students to raise their levels of achievement. Some Pennsylvania public high schools have attempted to improve student…

  14. Achievement Motivation in High School: Contrasting Theoretical Models in the Classroom.

    ERIC Educational Resources Information Center

    Garcia-Celay, I. Montero; Tapia, J. Alonso

    1992-01-01

    Three models of achievement motivation in the classroom are contrasted. Results with 155 high school students suggest that the model of C. S. Dweck and E. S. Elliott offers a better explanation of the relationships among achievement motivation, attributions, emotional reactions, expectancies, and performance than do the other models. (SLD)

  15. The Effects of Cooperative Learning on Student Achievement and Motivation in a High School Geometry Class.

    ERIC Educational Resources Information Center

    Nichols, Joe D.; Hall, Neff

    In this study, the effects of a form of cooperative group instruction (Student Teams Achievement Divisions) on student motivation and achievement in a high school geometry class were examined. Ninety (mostly 10th-grade) students were randomly assigned to either a control group receiving traditional instruction or one of two treatment groups…

  16. Early Reading Skills and Academic Achievement Trajectories of Students Facing Poverty, Homelessness, and High Residential Mobility

    ERIC Educational Resources Information Center

    Herbers, Janette E.; Cutuli, J. J.; Supkoff, Laura M.; Heistad, David; Chan, Chi-Keung; Hinz, Elizabeth; Masten, Ann S.

    2012-01-01

    This investigation tested the importance of early academic achievement for later achievement trajectories among 18,011 students grouped by level of socioeconomic risk. Students considered to be at highest risk were those who experienced homelessness or high residential mobility (HHM). HHM students were compared with students eligible for free…

  17. Intergenerational Closure and Academic Achievement in High School: A New Evaluation of Coleman's Conjecture

    ERIC Educational Resources Information Center

    Morgan, Stephen L.; Todd, Jennifer J.

    2009-01-01

    This article reexamines the conjecture of James S. Coleman that intergenerational social closure promotes student achievement in high schools, analyzing the best national data on academic achievement and social networks: the 2002 and 2004 waves of the Education Longitudinal Study. The results show that within the Catholic school sector, schools…

  18. Unforgiving Confucian Culture: A Breeding Ground for High Academic Achievement, Test Anxiety and Self-Doubt?

    ERIC Educational Resources Information Center

    Stankov, Lazar

    2010-01-01

    This paper reviews findings from several studies that contribute to our understanding of cross-cultural differences in academic achievement, anxiety and self-doubt. The focus is on comparisons between Confucian Asian and European regions. Recent studies indicate that high academic achievement of students from Confucian Asian countries is…

  19. Gender and High School Chemistry: Student Perceptions on Achievement in a Selective Setting

    ERIC Educational Resources Information Center

    Cousins, Andrew; Mills, Martin

    2015-01-01

    This paper reports on research undertaken in a middle-class Australian school. The focus of the research was on the relationship between gender and students' engagement with high school chemistry. Achievement data from many OECD [Organisation for Economic Co-operation and Development] countries suggest that middle-class girls are achieving equally…

  20. Parental Involvement, Homework, and TV Time: Direct and Indirect Effects on High School Achievement.

    ERIC Educational Resources Information Center

    Keith, Timothy Z.; And Others

    1986-01-01

    A set of High School and Beyond data was used to study the effect of three variables on academic achievement. Homework had a positive effect, TV a negative, and parental involvement no direct effect on seniors' achievement scores, but influenced the amount of time students spent on homework. (Author/JAZ)

  1. Highly stable and sensitive glucose biosensor based on covalently assembled high density Au nanostructures.

    PubMed

    Si, Peng; Kannan, Palanisamy; Guo, Longhua; Son, Hungsun; Kim, Dong-Hwan

    2011-05-15

    We describe the development of a highly stable and sensitive glucose biosensor based on the nanohybrid materials derived from gold nanoparticles (AuNPs) and multi-walled carbon nanotubes (MWCNT). The biosensing platform was developed by using layer-by-layer (LBL) self-assembly of the nanohybrid materials and the enzyme glucose oxidase (GOx). A high density of AuNPs and MWCNT nanocomposite materials were constructed by alternate self assembly of thiol functionalized MWCNTs and AuNPs, followed by chemisoption of GOx. The surface morphology of multilayered AuNPs/MWCNT structure was characterized by field emission-scanning electron microscope (FE-SEM), and the surface coverage of AuNPs was investigated by cyclic voltammetry (CV), showing that 5 layers of assembly achieves the maximum particle density on electrode. The immobilization of GOx was monitored by electrochemical impedance spectroscopy (EIS). CV and amperometry methods were used to study the electrochemical oxidation of glucose at physiological pH 7.4. The Au electrode modified with five layers of AuNPs/MWCNT composites and GOx exhibited an excellent electrocatalytic activity towards oxidation of glucose, which presents a wide liner range from 20 μM to 10 mM, with a sensitivity of 19.27 μA mM(-1) cm(-2). The detection limit of present modified electrode was found to be 2.3 μM (S/N=3). In addition, the resulting biosensor showed a faster amperometric current response (within 3 s) and low apparent Michaelis-Menten constant (K(m)(app)). Our present study shows that the high density of AuNPs decorated MWCNT is a promising nanohybrid material for the construction of enzyme based electrochemical biosensors.

  2. Impacts of comprehensive reading instruction on diverse outcomes of low- and high-achieving readers.

    PubMed

    Guthrie, John T; McRae, Angela; Coddington, Cassandra S; Lutz Klauda, Susan; Wigfield, Allan; Barbosa, Pedro

    2009-01-01

    Low-achieving readers in Grade 5 often lack comprehension strategies, domain knowledge, word recognition skills, fluency, and motivation to read. Students with such multiple reading needs seem likely to benefit from instruction that supports each of these reading processes. The authors tested this expectation experimentally by comparing the effects of Concept-Oriented Reading Instruction (CORI) with traditional instruction (TI) on several outcomes in a 12-week intervention for low achievers and high achievers. Low achievers in the CORI group were afforded explicit instruction, leveled texts, and motivation support. Compared with TI students, CORI students scored higher on posttest measures of word recognition speed, reading comprehension on the Gates-MacGinitie Reading Test, and ecological knowledge. CORI was equally effective for lower achievers and higher achievers. Explicitly supporting multiple aspects of reading simultaneously appeared to benefit diverse learners on a range of reading outcomes.

  3. Compact Tb doped fiber optic current sensor with high sensitivity.

    PubMed

    Huang, Duanni; Srinivasan, Sudharsanan; Bowers, John E

    2015-11-16

    A highly sensitive fiber optic current sensor using terbium doped fiber is presented. The Verdet constant of the terbium doped fiber at 1300nm is found to be 19.5μrad/A using both a polarimetric and interferometric type sensor. Measurements on a Sagnac-loop sensor using 10cm of terbium doped fiber placed inside a solenoid show over 40dB of open loop dynamic range as well as a minimum detectable current of 0.1mA. Extrapolations of our measurements show that in a practical setup with Tb fiber wrapped around a current carrying wire, the optimal configuration is a 0.5m piece of Tb fiber with a noise limit of 22mA/√Hz. This sensor is promising for current sensing applications that require high sensitivity and small size, weight, and power. PMID:26698480

  4. High-sensitivity acoustic sensors from nanofibre webs

    NASA Astrophysics Data System (ADS)

    Lang, Chenhong; Fang, Jian; Shao, Hao; Ding, Xin; Lin, Tong

    2016-03-01

    Considerable interest has been devoted to converting mechanical energy into electricity using polymer nanofibres. In particular, piezoelectric nanofibres produced by electrospinning have shown remarkable mechanical energy-to-electricity conversion ability. However, there is little data for the acoustic-to-electric conversion of electrospun nanofibres. Here we show that electrospun piezoelectric nanofibre webs have a strong acoustic-to-electric conversion ability. Using poly(vinylidene fluoride) as a model polymer and a sensor device that transfers sound directly to the nanofibre layer, we show that the sensor devices can detect low-frequency sound with a sensitivity as high as 266 mV Pa-1. They can precisely distinguish sound waves in low to middle frequency region. These features make them especially suitable for noise detection. Our nanofibre device has more than five times higher sensitivity than a commercial piezoelectric poly(vinylidene fluoride) film device. Electrospun piezoelectric nanofibres may be useful for developing high-performance acoustic sensors.

  5. Quantum-Dot-Sensitized Solar Cell with Unprecedentedly High Photocurrent

    PubMed Central

    Lee, Jin-Wook; Son, Dae-Yong; Ahn, Tae Kyu; Shin, Hee-Won; Kim, In Young; Hwang, Seong-Ju; Ko, Min Jae; Sul, Soohwan; Han, Hyouksoo; Park, Nam-Gyu

    2013-01-01

    The reported photocurrent density (JSC) of PbS quantum dot (QD)-sensitized solar cell was less than 19 mA/cm2 despite the capability to generate 38 mA/cm2, which results from inefficient electron injection and fast charge recombination. Here, we report on a PbS:Hg QD-sensitized solar cell with an unprecedentedly high JSC of 30 mA/cm2. By Hg2+ doping into PbS, JSC is almost doubled with improved stability. Femtosecond transient study confirms that the improved JSC is due to enhanced electron injection and suppressed charge recombination. EXAFS reveals that Pb-S bond is reinforced and structural disorder is reduced by interstitially incorporated Hg2+, which is responsible for the enhanced electron injection, suppressed recombination and stability. Thanks to the extremely high JSC, power conversion efficiency of 5.6% is demonstrated at one sun illumination. PMID:23308343

  6. Understanding the Elements of Operational Reliability: A Key for Achieving High Reliability

    NASA Technical Reports Server (NTRS)

    Safie, Fayssal M.

    2010-01-01

    This viewgraph presentation reviews operational reliability and its role in achieving high reliability through design and process reliability. The topics include: 1) Reliability Engineering Major Areas and interfaces; 2) Design Reliability; 3) Process Reliability; and 4) Reliability Applications.

  7. Horizontal film balance having wide range and high sensitivity

    DOEpatents

    Abraham, B.M.; Miyano, K.; Ketterson, J.B.

    1981-03-05

    A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed.

  8. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates

    PubMed Central

    Bleeck, Stefan; McAlpine, David

    2015-01-01

    Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor—to the point of discrimination thresholds being unattainable—compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners’ sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926

  9. Sensitivity to Envelope Interaural Time Differences at High Modulation Rates.

    PubMed

    Monaghan, Jessica J M; Bleeck, Stefan; McAlpine, David

    2015-01-01

    Sensitivity to interaural time differences (ITDs) conveyed in the temporal fine structure of low-frequency tones and the modulated envelopes of high-frequency sounds are considered comparable, particularly for envelopes shaped to transmit similar fidelity of temporal information normally present for low-frequency sounds. Nevertheless, discrimination performance for envelope modulation rates above a few hundred Hertz is reported to be poor-to the point of discrimination thresholds being unattainable-compared with the much higher (>1,000 Hz) limit for low-frequency ITD sensitivity, suggesting the presence of a low-pass filter in the envelope domain. Further, performance for identical modulation rates appears to decline with increasing carrier frequency, supporting the view that the low-pass characteristics observed for envelope ITD processing is carrier-frequency dependent. Here, we assessed listeners' sensitivity to ITDs conveyed in pure tones and in the modulated envelopes of high-frequency tones. ITD discrimination for the modulated high-frequency tones was measured as a function of both modulation rate and carrier frequency. Some well-trained listeners appear able to discriminate ITDs extremely well, even at modulation rates well beyond 500 Hz, for 4-kHz carriers. For one listener, thresholds were even obtained for a modulation rate of 800 Hz. The highest modulation rate for which thresholds could be obtained declined with increasing carrier frequency for all listeners. At 10 kHz, the highest modulation rate at which thresholds could be obtained was 600 Hz. The upper limit of sensitivity to ITDs conveyed in the envelope of high-frequency modulated sounds appears to be higher than previously considered. PMID:26721926

  10. Horizontal film balance having wide range and high sensitivity

    DOEpatents

    Abraham, Bernard M.; Miyano, Kenjiro; Ketterson, John B.

    1983-01-01

    A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed.

  11. Horizontal film balance having wide range and high sensitivity

    DOEpatents

    Abraham, B.M.; Miyano, K.; Ketterson, J.B.

    1983-11-08

    A thin-film, horizontal balance instrument is provided for measuring surface tension (surface energy) of thin films suspended on a liquid substrate. The balance includes a support bearing and an optical feedback arrangement for wide-range, high sensitivity measurements. The force on the instrument is balanced by an electromagnet, the current through the magnet providing a measure of the force applied to the instrument. A novel float construction is also disclosed. 5 figs.

  12. Structural Glycomic Analyses at High Sensitivity: A Decade of Progress

    PubMed Central

    Alley, William R.; Novotny, Milos V.

    2014-01-01

    The field of glycomics has recently advanced in response to the urgent need for structural characterization and quantification of complex carbohydrates in biologically and medically important applications. The recent success of analytical glycobiology at high sensitivity reflects numerous advances in biomolecular mass spectrometry and its instrumentation, capillary and microchip separation techniques, and microchemical manipulations of carbohydrate reactivity. The multimethodological approach appears to be necessary to gain an in-depth understanding of very complex glycomes in different biological systems. PMID:23560930

  13. High efficiency neutron sensitive amorphous silicon pixel detectors

    SciTech Connect

    Mireshghi, A.; Cho, G.; Drewery, J.S.; Hong, W.S.; Jing, T.; Lee, H.; Kaplan, S.N.; Perez-Mendez, V.

    1993-11-01

    A multi-layer a-Si:H based thermal neutron detector was designed, fabricated and simulated by Monte Carlo method. The detector consists of two PECVD deposited a-Si:H pin detectors interfaced with coated layers of Gd, as a thermal neutron converter. Simulation results indicate that a detector consisting of 2 Gd films with thicknesses of 2 and 4 {mu}m, sandwiched properly with two layers of sufficiently thick ({approximately}30{mu}m) amorphous silicon diodes, has the optimum parameters. The detectors have an intrinsic efficiency of about 42% at a threshold setting of 7000 electrons, with an expected average signal size of {approximately}12000 electrons which is well above the noise. This efficiency will be further increased to nearly 63%, if we use Gd with 50% enrichment in {sup 157}Gd. We can fabricate position sensitive detectors with spatial resolution of 300 {mu}m with gamma sensitivity of {approximately}1 {times} 10{sup {minus}5}. These detectors are highly radiation resistant and are good candidates for use in various application, where high efficiency, high resolution, gamma insensitive position sensitive neutron detectors are needed.

  14. Highly sensitive methods for electroanalytical chemistry based on nanotubule membranes.

    PubMed

    Kobayashi, Y; Martin, C R

    1999-09-01

    Two new methods of electroanalysis are described. These methods are based on membranes containing monodisperse Au nanotubules with inside diameters approaching molecular dimensions. In one method, the analyte species is detected by measuring the change in trans-membrane current when the analyte is added to the nanotubule-based cell. The second method entails the use of a concentration cell based on the nanotubule membrane. In this case, the change in membrane potential is used to detect the analyte. Detection limits as low as 10(-11) M have been achieved. Hence, these methods compete with even the most sensitive of modern analytical methodologies. In addition, excellent molecular-sized-based selectivity is observed.

  15. Do Peers Influence Achievement in High School Economics? Evidence from Georgia's Economics End of Course Test

    ERIC Educational Resources Information Center

    Clark, Christopher; Scafidi, Benjamin; Swinton, John R.

    2011-01-01

    The authors provide the first estimates of the impact of peers on achievement in high school economics. The estimates are obtained by analyzing three years of data on all high school students who take Georgia's required economics course and its accompanying high-stakes End of Course Test (Georgia Department of Education). They use an instrumental…

  16. A Study of Professional Learning Communities and Science Achievement in Large High Schools

    ERIC Educational Resources Information Center

    Kincannon, Susan D.

    2010-01-01

    The purpose of this study was to compare the science achievement and high school completion rates of students in a large high school implementing professional learning community concepts and practices with two large high schools not participating in professional learning community concepts and practices. The primary methodology employed was a…

  17. A novel high-sensitivity electrostatic biased electric field sensor

    NASA Astrophysics Data System (ADS)

    Huang, Jing'ao; Wu, Xiaoming; Wang, Xiaohong; Yan, Xiaojun; Lin, Liwei

    2015-09-01

    In this paper, an electric field sensor (EFS) with high sensitivity is proposed for low-frequency weak-strength ac electric field (E-field) measurements. The EFS is based on a piezoelectric cantilever biased by a strong electrostatic field. The electrostatic bias can enhance the electric field force of a weak ac E-field, thus the cantilever can oscillate in a weak ac E-field and the device sensitivity improves. Theoretical analyses have been established and suggest that a stronger strength of electrostatic field bias would produce a higher sensitivity improvement. In the experiment, a demonstrated sensor consisting of a polyvinylidene fluoride (PVDF) piezoelectric cantilever and a polytetrafluoroethylene (PTFE) electret was built and tested. Instead of extra voltage sources, the PTFE electret was charged to provide the electrostatic field, allowing the EFS a low energy consumption and a simple electric circuit design. The experiment results show good agreement with the simulation. The sensitivity of the cantilever E-field sensor reached 0.84 mV (kV/m)-1 when the surface potential of the electret was  -770 V.

  18. The Outward Bound Bridging Course for Low-Achieving High School Males: Effect on Academic Achievement and Multidimensional Self-Concepts.

    ERIC Educational Resources Information Center

    Marsh, Herbert W.; Richards, Garry

    The Outward Bound Bridging Course is a 6-week residential program designed to improve academic achievement and self-concepts in low-achieving high school males. During 1980-1984, five courses were conducted for 66 Australian high school males. Most of them were ninth grade students, chosen on the basis of poor academic performance, an apparent…

  19. A Comparison of Emotional-Motivational (A-R-D Theory) Personality Characteristics in Learning Disabled, Normal Achieving, and High Achieving Children.

    ERIC Educational Resources Information Center

    Hufano, Linda D.

    The study examined emotional-motivational personality characteristics of 15 learning disabled, 15 normal achieving, and 15 high achieving students (grades 3-5). The study tested the hypothesis derived from the A-R-D (attitude-reinforcer-discriminative) theory of motivation that learning disabled (LD) children differ from normal and high achieving…

  20. Modulated fiber ring laser and its application in high-sensitivity temperature sensors

    NASA Astrophysics Data System (ADS)

    Perez-Herrera, R. A.; Tainta, S.; Erro, M. J.; Lopez-Amo, M.

    2016-05-01

    This work presents an experimental demonstration of a scheme based on an internally modulated fiber ring laser for high-sensitivity temperature sensing. The attained temperature resolution has been as low as +/- 2pm even when a commercial FBG with a sensitivity of 10 pm/°C was used. Thus, a fivefold improvement in the temperature sensor resolution can be achieved when compared to a simple FBG interrogation scheme. In addition to this, the measuring range could be selected only by changing the frequency modulation of the fiber ring laser. This technology also allows to triple the photodiode bandwidth unambiguously when temperature or strain measurements are carried out, which is a remarkable achievement in term of cost reduction.

  1. All-fiber high-sensitivity pressure sensor with SiO2 diaphragm.

    PubMed

    Donlagic, Denis; Cibula, Edvard

    2005-08-15

    The design and fabrication of a miniature fiber Fabry-Perot pressure sensor with a diameter of 125 microm are presented. The essential element in the process is a thin SiO2 diaphragm that is fusion spliced at the hollow end of an optical fiber. Good repeatability and high sensitivity of the sensor are achieved by on-line tuning of the diaphragm thickness during the sensor fabrication process. Various sensor prototypes were fabricated, demonstrating pressure ranges of from 0 to 40 kPa to 0 to 1 MPa. The maximum achieved sensitivity was 1.1 rad/40 kPa at 1550 nm, and a pressure resolution of 300 Pa was demonstrated in practice. The presented design and fabrication technique offers a means of simple and low-cost disposable pressure sensor production. PMID:16127913

  2. High sensitive volumetric imaging of renal microcirculation in vivo using ultrahigh sensitive optical microangiography

    NASA Astrophysics Data System (ADS)

    Zhi, Zhongwei; Jung, Yeongri; Jia, Yali; An, Lin; Wang, Ruikang K.

    2011-03-01

    We present a non-invasive, label-free imaging technique called Ultrahigh Sensitive Optical Microangiography (UHSOMAG) for high sensitive volumetric imaging of renal microcirculation. The UHS-OMAG imaging system is based on spectral domain optical coherence tomography (SD-OCT), which uses a 47000 A-line scan rate CCD camera to perform an imaging speed of 150 frames per second that takes only ~7 seconds to acquire a 3D image. The technique, capable of measuring slow blood flow down to 4 um/s, is sensitive enough to image capillary networks, such as peritubular capillaries and glomerulus within renal cortex. We show superior performance of UHS-OMAG in providing depthresolved volumetric images of rich renal microcirculation. We monitored the dynamics of renal microvasculature during renal ischemia and reperfusion. Obvious reduction of renal microvascular density due to renal ischemia was visualized and quantitatively analyzed. This technique can be helpful for the assessment of chronic kidney disease (CKD) which relates to abnormal microvasculature.

  3. Development of a highly sensitive galvanic cell oxygen sensor.

    PubMed

    Ogino, H; Asakura, K

    1995-02-01

    A highly sensitive galvanic cell oxygen sensor was successfully developed for determining parts per billion of oxygen in high purity gases such as nitrogen, argon, etc. The response of this improved sensor was proportional in the range of oxygen concentrations from 10.0 ppm to the detection limit. The response speed in this study was improved to within 90 sec for a 90% response. The detection limit was tentatively found to be less than 0.4 ppb corresponding to S N = 2 .

  4. A highly sensitive refractometric sensor based on cascaded SiN microring resonators.

    PubMed

    Zamora, Vanessa; Lützow, Peter; Weiland, Martin; Pergande, Daniel

    2013-01-01

    We investigate a highly sensitive optical sensor based on two cascaded microring resonators exploiting the Vernier effect. The architecture consists of two microrings with a slight difference in their free spectral ranges. This allows the generation of the Vernier effect for achieving ultra-high sensitivities. The sensor chip was fabricated using a silicon nitride platform and characterized with isopropanol/ethanol mixtures. A sensitivity of 0.95 nm/% was found for isopropanol concentrations in ethanol ranging from 0% to 10%. Furthermore, a collection of measurements was carried out using aqueous sodium chloride (NaCl) in solutions of different concentrations, confirming a high sensitivity of 10.3 nm/% and a bulk refractive index sensitivity of 6,317 nm/RIU. A limit of detection of 3.16 × 10(-6) RIU was determined. These preliminary results show the potential features of cascaded silicon nitride microring resonators for real-time and free-label monitoring of biomolecules for a broad range of applications. PMID:24169543

  5. In situ, high sensitivity, measurement of 90strontium in ground water using Cherenkov light

    NASA Astrophysics Data System (ADS)

    Bowyer, T. W.; Geelhood, B. D.; Hossbach, T. W.; Hansen, R.; Wilcox, W. A.

    2000-03-01

    The measurement of 90Sr in soils and ground water is important for characterization and remediation of radioactively contaminated sites. Measuring the 90Sr content to a few pCi/g of soil has been accomplished based on a design of scintillating fibers in a multilayered configuration measuring the high-energy beta emitted from 90Y decay (when in secular equilibrium with 90Sr), but has not been applied to water because the technique is sensitive to only the first few mm of soil. The volume of the source to which the detector is sensitive limits the theoretical sensitivity of such a detector, unless chemical preprocessing to strip the 90Sr from the water is performed. 90Sr activity in water can be quantified by detecting the high-energy beta particle by the Cherenkov light it produces when the high-energy beta from 90Y passes through the medium. We have used this phenomenon to sensitively measure 90Sr ( 90Y) from a volume of water large enough (765 cm 3) to make very sensitive measurements with short count times. For counting intervals of about 1000 s, we were able to achieve a minimum detectable concentration (MDC) (at 4.65 σ above background) of 14 pCi/L, and for 3000 s counts the MDC dropped to the drinking water limit of 8 pCi/L.

  6. A Highly Sensitive Refractometric Sensor Based on Cascaded SiN Microring Resonators

    PubMed Central

    Zamora, Vanessa; Lützow, Peter; Weiland, Martin; Pergande, Daniel

    2013-01-01

    We investigate a highly sensitive optical sensor based on two cascaded microring resonators exploiting the Vernier effect. The architecture consists of two microrings with a slight difference in their free spectral ranges. This allows the generation of the Vernier effect for achieving ultra-high sensitivities. The sensor chip was fabricated using a silicon nitride platform and characterized with isopropanol/ethanol mixtures. A sensitivity of 0.95 nm/% was found for isopropanol concentrations in ethanol ranging from 0% to 10%. Furthermore, a collection of measurements was carried out using aqueous sodium chloride (NaCl) in solutions of different concentrations, confirming a high sensitivity of 10.3 nm/% and a bulk refractive index sensitivity of 6,317 nm/RIU. A limit of detection of 3.16 × 10−6 RIU was determined. These preliminary results show the potential features of cascaded silicon nitride microring resonators for real-time and free-label monitoring of biomolecules for a broad range of applications. PMID:24169543

  7. A highly sensitive refractometric sensor based on cascaded SiN microring resonators.

    PubMed

    Zamora, Vanessa; Lützow, Peter; Weiland, Martin; Pergande, Daniel

    2013-01-01

    We investigate a highly sensitive optical sensor based on two cascaded microring resonators exploiting the Vernier effect. The architecture consists of two microrings with a slight difference in their free spectral ranges. This allows the generation of the Vernier effect for achieving ultra-high sensitivities. The sensor chip was fabricated using a silicon nitride platform and characterized with isopropanol/ethanol mixtures. A sensitivity of 0.95 nm/% was found for isopropanol concentrations in ethanol ranging from 0% to 10%. Furthermore, a collection of measurements was carried out using aqueous sodium chloride (NaCl) in solutions of different concentrations, confirming a high sensitivity of 10.3 nm/% and a bulk refractive index sensitivity of 6,317 nm/RIU. A limit of detection of 3.16 × 10(-6) RIU was determined. These preliminary results show the potential features of cascaded silicon nitride microring resonators for real-time and free-label monitoring of biomolecules for a broad range of applications.

  8. High-sensitivity strain visualization using electroluminescence technologies

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Jo, Hongki

    2016-04-01

    Visualizing mechanical strain/stress changes is an emerging area in structural health monitoring. Several ways are available for strain change visualization through the color/brightness change of the materials subjected to the mechanical stresses, for example, using mechanoluminescence (ML) materials and mechanoresponsive polymers (MRP). However, these approaches were not effectively applicable for civil engineering system yet, due to insufficient sensitivity to low-level strain of typical civil structures and limitation in measuring both static and dynamic strain. In this study, design and validation for high-sensitivity strain visualization using electroluminescence technologies are presented. A high-sensitivity Wheatstone bridge, of which bridge balance is precisely controllable circuits, is used with a gain-adjustable amplifier. The monochrome electroluminescence (EL) technology is employed to convert both static and dynamic strain change into brightness/color change of the EL materials, through either brightness change mode (BCM) or color alternation mode (CAM). A prototype has been made and calibrated in lab, the linearity between strain and brightness change has been investigated.

  9. High sensitivity, homogeneous particle-based immunoassay for thyrotropin (Multipact).

    PubMed

    Wilkins, T A; Brouwers, G; Mareschal, J C; Cambiaso, C L

    1988-09-01

    We describe the first homogeneous, nonradioactive, high-sensitivity assay for human thyrotropin (TSH). The assay is based on particle immunoassay techniques, wherein 800-nm particles form the basis for the immunochemistry, delivery, and the detection technologies, respectively. Our assay also is the first to involve the use of fragmented monoclonal antibodies (to eliminate serum interferences) covalently coupled to particles without loss of their binding properties. Assays are performed in a semiautomated mode with use of a new modular system (Multipact). Equilibrium is reached in less than 2 h. Precision profile, sensitivity, and clinical studies indicate that the assay is accurate, has good precision at low concentrations, and that detection-limit characteristics compare well with those of a leading commercial high-sensitivity immunoradiometric assay (IRMA) for TSH. Dilution characteristics were satisfactory down to the assay's detection limit for a range of clinical samples. Correlation studies vs a reference IRMA method yielded the regression equation, present method = 0.976 (IRMA) + 0.002 milli-int. unit/L (r = 0.98), for 223 samples with TSH concentrations in the range 0 to 30 milli-int. units/L. For 40 samples with TSH less than or equal to 1.0 milli-int. unit/L it was: present method = 0.94 (IRMA) + 0.005 milli-int. unit/L (r = 0.96). PMID:3416423

  10. Highly Sensitive Measurements of 222Rn Diffusion and Emanation

    SciTech Connect

    Zuzel, Grzegorz

    2005-09-08

    Highly sensitive techniques for determination of the 222Rn emanation from solids and diffusion through different membranes are presented. 222Rn and its daughters are measured via the alpha decays in special proportional counters at the absolute sensitivity of {approx}30 {mu}Bq. Radon diffusion can be measured at the level of {approx}10-13 cm2/s. Several samples were examined, e.g. stainless steel, teflon, various gaskets (emanation and diffusion measurements) and tanks. A combination of measurements of the 222Rn diffusion and emanation of thin nylon foils (used in the Borexino experiment) allowed the determination of 226Ra in the materials of interest at the level of {approx}10-12 g/g 238U-equivalent.

  11. Polymer-Particle Pressure-Sensitive Paint with High Photostability.

    PubMed

    Matsuda, Yu; Uchida, Kenta; Egami, Yasuhiro; Yamaguchi, Hiroki; Niimi, Tomohide

    2016-04-16

    We propose a novel fast-responding and paintable pressure-sensitive paint (PSP) based on polymer particles, i.e. polymer-particle (pp-)PSP. As a fast-responding PSP, polymer-ceramic (PC-)PSP is widely studied. Since PC-PSP generally consists of titanium (IV) oxide (TiO₂) particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO₂. We propose the usage of polymer particles instead of TiO₂ particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP.

  12. Sensitivity to Error Fields in NSTX High Beta Plasmas

    SciTech Connect

    Park, Jong-Kyu; Menard, Jonathan E.; Gerhardt, Stefan P.; Buttery, Richard J.; Sabbagh, Steve A.; Bell, Steve E.; LeBlanc, Benoit P.

    2011-11-07

    It was found that error field threshold decreases for high β in NSTX, although the density correlation in conventional threshold scaling implies the threshold would increase since higher β plasmas in our study have higher plasma density. This greater sensitivity to error field in higher β plasmas is due to error field amplification by plasmas. When the effect of amplification is included with ideal plasma response calculations, the conventional density correlation can be restored and threshold scaling becomes more consistent with low β plasmas. However, it was also found that the threshold can be significantly changed depending on plasma rotation. When plasma rotation was reduced by non-resonant magnetic braking, the further increase of sensitivity to error field was observed.

  13. High derivatives for fast sensitivity analysis in linear magnetodynamics

    SciTech Connect

    Petin, P. |; Coulomb, J.L.; Conraux, P.

    1997-03-01

    In this article, the authors present a method of sensitivity analysis using high derivatives and Taylor development. The principle is to find a polynomial approximation of the finite elements solution towards the sensitivity parameters. While presenting the method, they explain why this method is applicable with special parameters only. They applied it on a magnetodynamic problem, simple enough to be able to find the analytical solution with a formal calculus tool. They then present the implementation and the good results obtained with the polynomial, first by comparing the derivatives themselves, then by comparing the approximate solution with the theoretical one. After this validation, the authors present results on a real 2D application and they underline the possibilities of reuse in other fields of physics.

  14. Polymer-Particle Pressure-Sensitive Paint with High Photostability

    PubMed Central

    Matsuda, Yu; Uchida, Kenta; Egami, Yasuhiro; Yamaguchi, Hiroki; Niimi, Tomohide

    2016-01-01

    We propose a novel fast-responding and paintable pressure-sensitive paint (PSP) based on polymer particles, i.e. polymer-particle (pp-)PSP. As a fast-responding PSP, polymer-ceramic (PC-)PSP is widely studied. Since PC-PSP generally consists of titanium (IV) oxide (TiO2) particles, a large reduction in the luminescent intensity will occur due to the photocatalytic action of TiO2. We propose the usage of polymer particles instead of TiO2 particles to prevent the reduction in the luminescent intensity. Here, we fabricate pp-PSP based on the polystyrene particle with a diameter of 1 μm, and investigate the pressure- and temperature-sensitives, the response time, and the photostability. The performances of pp-PSP are compared with those of PC-PSP, indicating the high photostability with the other characteristics comparable to PC-PSP. PMID:27092511

  15. A high sensitivity pressure sensor based on two-dimensional photonic crystal

    NASA Astrophysics Data System (ADS)

    Tao, Shangbin; Chen, Deyuan; Wang, Juebin; Qiao, Jing; Duan, Yali

    2016-06-01

    In this paper, we propose and simulate a pressure sensor based on two-dimensional photonic crystal with the high quality factor and sensitivity. The sensor is formed by the coupling of two photonic crystal based waveguides and one nanocavity. The photonic crystal with the triangular lattice is composed of GaAs rods. The detailed structures of the waveguides and nanocavity are optimized to achieve better quality factor and sensitivity of the sensor. For the optimized structures, the resonant wavelength of the sensor has a linear redshift as increasing the applied pressure in the range of 0-2 GPa, and the quality factor keeps unchanged nearly. The optimized quality factor is around 1500, and the sensitivity is up to 13.9 nm/GPa.

  16. A CMOS In-Pixel CTIA High Sensitivity Fluorescence Imager

    PubMed Central

    Murari, Kartikeya; Etienne-Cummings, Ralph; Thakor, Nitish; Cauwenberghs, Gert

    2012-01-01

    Traditionally, charge coupled device (CCD) based image sensors have held sway over the field of biomedical imaging. Complementary metal oxide semiconductor (CMOS) based imagers so far lack sensitivity leading to poor low-light imaging. Certain applications including our work on animal-mountable systems for imaging in awake and unrestrained rodents require the high sensitivity and image quality of CCDs and the low power consumption, flexibility and compactness of CMOS imagers. We present a 132×124 high sensitivity imager array with a 20.1 μm pixel pitch fabricated in a standard 0.5 μ CMOS process. The chip incorporates n-well/p-sub photodiodes, capacitive transimpedance amplifier (CTIA) based in-pixel amplification, pixel scanners and delta differencing circuits. The 5-transistor all-nMOS pixel interfaces with peripheral pMOS transistors for column-parallel CTIA. At 70 fps, the array has a minimum detectable signal of 4 nW/cm2 at a wavelength of 450 nm while consuming 718 μA from a 3.3 V supply. Peak signal to noise ratio (SNR) was 44 dB at an incident intensity of 1 μW/cm2. Implementing 4×4 binning allowed the frame rate to be increased to 675 fps. Alternately, sensitivity could be increased to detect about 0.8 nW/cm2 while maintaining 70 fps. The chip was used to image single cell fluorescence at 28 fps with an average SNR of 32 dB. For comparison, a cooled CCD camera imaged the same cell at 20 fps with an average SNR of 33.2 dB under the same illumination while consuming over a watt. PMID:23136624

  17. A Monolithic CMOS Magnetic Hall Sensor with High Sensitivity and Linearity Characteristics.

    PubMed

    Huang, Haiyun; Wang, Dejun; Xu, Yue

    2015-10-27

    This paper presents a fully integrated linear Hall sensor by means of 0.8 μm high voltage complementary metal-oxide semiconductor (CMOS) technology. This monolithic Hall sensor chip features a highly sensitive horizontal switched Hall plate and an efficient signal conditioner using dynamic offset cancellation technique. An improved cross-like Hall plate achieves high magnetic sensitivity and low offset. A new spinning current modulator stabilizes the quiescent output voltage and improves the reliability of the signal conditioner. The tested results show that at the 5 V supply voltage, the maximum Hall output voltage of the monolithic Hall sensor microsystem, is up to ±2.1 V and the linearity of Hall output voltage is higher than 99% in the magnetic flux density range from ±5 mT to ±175 mT. The output equivalent residual offset is 0.48 mT and the static power consumption is 20 mW.

  18. [Highly sensitive detection technology for biological toxins applying sugar epitopes].

    PubMed

    Uzawa, Hirotaka

    2009-01-01

    The Shiga toxin is a highly poisonous protein produced by enterohemorrhagic Escherichia coli O157. This bacterial toxin causes the hemolytic uremic syndrome. Another plant toxin from castor beans, ricin, is also highly toxic. The toxin was used for assassination in London. Recently, there were several cases of postal matter containing ricin. Both toxins are categorized as biological warfare agents by the Centers of Disease Control and Prevention. Conventional detection methods based on the antigen-antibody reaction, PCR and other cell-free assays have been proposed. However, those approaches have drawbacks in terms of sensitivity, analytical time, or stability of the detection reagents. Therefore, development of a facile and sensitive detection method is essential. Here we describe new detection methods applying carbohydrate epitopes as the toxin ligands, which is based on the fact that the toxins bind cell-surface oligosaccharides. Namely, the Shiga toxin has an affinity for globobiosyl (Gb(2)) disaccharide, and ricin binds the beta-D-galactose residue. For Shiga toxin detection, surface plasmon resonance (SPR) was applied. A polyanionic Gb(2)-glycopolymer was designed for this purpose, and it was used for the assembly of Gb(2)-chips using alternating layer-by-layer technology. The method allowed us to detect the toxin at a low concentration of LD(50). A synthetic carbohydrate ligand for ricin was designed and immobilized on the chips. SPR analysis with the chips allows us to detect ricin in a highly sensitive and facile manner (10 pg/ml, 5 min). Our present approaches provide a highly effective way to counter bioterrorism.

  19. Social Goals, Social Status, and Problem Behavior among Low-Achieving and High-Achieving Adolescents from Rural Schools

    ERIC Educational Resources Information Center

    Ludden, Alison Bryant

    2012-01-01

    The current research examines how social goals and perceptions of what is needed for social status at school relate to school misbehavior and substance use among rural adolescents (N = 683). Results indicate that social goals and perceptions of social status have differential links to problem behaviors depending upon adolescents' achievement.…

  20. Evaluation of English Achievement Test: A Comparison between High and Low Achievers amongst Selected Elementary School Students of Pakistan

    ERIC Educational Resources Information Center

    Haider, Zubair; Latif, Farah; Akhtar, Samina; Mushtaq, Maria

    2012-01-01

    Validity, reliability and item analysis are critical to the process of evaluating the quality of an educational measurement. The present study evaluates the quality of an assessment constructed to measure elementary school student's achievement in English. In this study, the survey model of descriptive research was used as a research method.…

  1. Emotional Intelligence as a Predictor of Leadership of Kuwaiti High and Low Achieving 11th Graders

    ERIC Educational Resources Information Center

    Alnabhan, Mousa

    2010-01-01

    The current study examined the association between emotional intelligence (EI) and the Leadership components (L) of high school students in the state of Kuwait. The possibility of predicting each leadership component via emotional intelligence components was investigated for high and low achievers. A sample of 11th grade students from Kuwaiti…

  2. What Works Clearinghouse Quick Review: "Expanding College Opportunities for High-Achieving, Low Income Students"

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2013

    2013-01-01

    This study examined the effects of providing low-income, high-achieving high school seniors with college application guidance and information about the costs of college. The "application guidance" included information about deadlines and requirements for college applications at nearby institutions, at the state's flagship institution, and at in-…

  3. The Effects of Modeling Instruction on High School Physics Academic Achievement

    ERIC Educational Resources Information Center

    Wright, Tiffanie L.

    2012-01-01

    The purpose of this study was to explore whether Modeling Instruction, compared to traditional lecturing, is an effective instructional method to promote academic achievement in selected high school physics classes at a rural middle Tennessee high school. This study used an "ex post facto," quasi-experimental research methodology. The…

  4. Effects of an Elementary Dual Language Immersion School Program on Junior High Achievement

    ERIC Educational Resources Information Center

    Cobb, Brian; Vega, Diego; Kronauge, Cindy

    2006-01-01

    The purpose of this study was to analyze the effects of a two-way immersion elementary school program on academic achievement at the end of the elementary school and the end of the first year of junior high school. Longitudinal high stakes test data in reading, writing, and mathematics were collected on native English speakers and native Spanish…

  5. The Relationship between Self-Efficacy and Achievement in At-Risk High School Students

    ERIC Educational Resources Information Center

    Gold, Jarrett Graham

    2010-01-01

    The focus of this quantitative survey study was the examination of the relationship between self-efficacy and academic achievement in 164 at-risk high school students. The study used Bandura's self-efficacy as the theoretical framework. The research questions involved understanding the levels of self-efficacy in at-risk high school students and…

  6. Small Classes in the Early Grades, Academic Achievement, and Graduating From High School

    ERIC Educational Resources Information Center

    Finn, Jeremy D.; Gerber, Susan B.; Boyd-Zaharias, Jayne

    2005-01-01

    This investigation addressed 3 questions about the long-term effects of early school experiences: (a) Is participation in small classes in the early grades (K-3) related to high school graduation? (b) Is academic achievement in K-3 related to high school graduation? (c) If class size is related to graduation, is the relationship explained by the…

  7. Mathematics Achievement with Digital Game-Based Learning in High School Algebra 1 Classes

    ERIC Educational Resources Information Center

    Ferguson, Terri Lynn Kurley

    2014-01-01

    This study examined the impact of digital game-based learning (DGBL) on mathematics achievement in a rural high school setting in North Carolina. A causal comparative research design was used in this study to collect data to determine the effectiveness of DGBL in high school Algebra 1 classes. Data were collected from the North Carolina…

  8. Towards Promoting Biliteracy and Academic Achievement: Educational Programs for High School Latino English Language Learners

    ERIC Educational Resources Information Center

    Ochoa, Alberto M.; Cadiero-Kaplan, Karen

    2004-01-01

    The Latino student presently faces many obstacles to achieve educational equity and excellence at the high school level. This article examines academic programming for Latino middle and high school English language learners (ELLs) and provides recommendations for addressing programming that promotes biliteracy policy and programming as a valued…

  9. A Case Study of 21st Century Skills in High Achieving Elementary Schools in Pennsylvania

    ERIC Educational Resources Information Center

    Egnor, Gregory P.

    2013-01-01

    This study examines if practices that advocate for 21st century skills are in conflict with the mandates of NCLB. Interviews with influential school leaders of high achieving elementary schools focused on collecting data about 21st century skills. This study was designed to (a) Determine if 21st century skills are addressed in high achieving…

  10. Achieve Scholarship Spending on Expanding Access to Rigorous High School Courses

    ERIC Educational Resources Information Center

    Minnesota Office of Higher Education, 2009

    2009-01-01

    The 2007 Legislature enacted the Achieve Scholarship program, which provides a $1,200 scholarship to high school graduates who took rigorous courses in high school and met certain income and other eligibility criteria. In deliberations about this new program, concerns were expressed that certain rigorous courses like Advanced Placement,…

  11. Study-Orientation of High and Low Academic Achievers at Secondary Level in Pakistan

    ERIC Educational Resources Information Center

    Sarwar, Muhammad; Bashir, Muhammad; Khan, Muhammad Naemullah; Khan, Muhammad Saeed

    2009-01-01

    The study orientation of low and high academic achievers was compared, measured through a self-developed study orientation scale (SOS) primarily based on 47 items comparing study habits and attitude. Students' marks obtained in the 10th grade Examination determined the measure of academic performance. The analysis revealed that the high achievers…

  12. Piezoelectric rubber films for highly sensitive impact measurement

    NASA Astrophysics Data System (ADS)

    Wang, Jhih-Jhe; Tsai, Jui-Wei; Su, Yu-Chuan

    2013-07-01

    We have successfully demonstrated the microfabrication of piezoelectric rubber films and their application in impact measurement. To realize the desired piezoelectricity and stretchability, cellular polydimethylsiloxane (PDMS) structures with micrometer-sized voids are internally implanted with bipolar charges, which function as dipoles and respond promptly to electromechanical stimuli. In the prototype demonstration, 300 µm thick cellular PDMS films are fabricated and internally coated with a thin polytetrafluoroethylene (PTFE) layer to secure the implanted charges. Meanwhile, the top and bottom surfaces of the cellular PDMS films are deposited with stretchable gold electrodes. An electric field up to 35 MV m-1 is applied across the gold electrodes to ionize the air in the voids and to implant charges on the inner surfaces. The resulting composite structures behave like rubber (with an elastic modulus of about 300 kPa) and show strong piezoelectricity (with a piezoelectric coefficient d33 higher than 1000 pC N-1). While integrated with a wide bandwidth and large dynamic-range charge amplifier, highly sensitive impact measurement (with a stress sensitivity of about 10 mV Pa-1) is demonstrated. As such, the demonstrated piezoelectric rubber films could potentially serve as a sensitive electromechanical material for low-frequency stimuli, and fulfill the needs of a variety of physiological monitoring and wearable electronics applications.

  13. Position sensitive detection of neutrons in high radiation background field

    SciTech Connect

    Vavrik, D.; Jakubek, J.; Pospisil, S.; Vacik, J.

    2014-01-15

    We present the development of a high-resolution position sensitive device for detection of slow neutrons in the environment of extremely high γ and e{sup −} radiation background. We make use of a planar silicon pixelated (pixel size: 55 × 55 μm{sup 2}) spectroscopic Timepix detector adapted for neutron detection utilizing very thin {sup 10}B converter placed onto detector surface. We demonstrate that electromagnetic radiation background can be discriminated from the neutron signal utilizing the fact that each particle type produces characteristic ionization tracks in the pixelated detector. Particular tracks can be distinguished by their 2D shape (in the detector plane) and spectroscopic response using single event analysis. A Cd sheet served as thermal neutron stopper as well as intensive source of gamma rays and energetic electrons. Highly efficient discrimination was successful even at very low neutron to electromagnetic background ratio about 10{sup −4}.

  14. Ultra-high sensitivity moment magnetometry of geological samples

    NASA Astrophysics Data System (ADS)

    Andrade Lima, E.; Weiss, B. P.

    2012-12-01

    Scanning SQUID microscopy offers a unique combination of high spatial resolution and magnetic field sensitivity that allows for the detection of magnetic moments as weak as 10^-16 Am2. This opens the possibility of extending paleomagnetic analyses to samples that have not been accessible to standard moment magnetometry, for which the detection limit is 10^-12 Am2. Of particular interest are individual terrestrial and extraterrestrial particles of small size (< 500 μm) that may preserve records of planetary dynamos and early nebular magnetic fields. Example targets include impact melt spherules, zircon and other silicate crystals, micrometeorites, cosmic dust, chondrules and refractory inclusions. These grains may be adequately modeled as small uniformly magnetized volumes, such that retrieving their magnetic moments from measured magnetic field maps does not require solving non-unique inverse problems. As a consequence, SQUID microscopes can be utilized as ultra-high sensitivity moment magnetometers. We show alternating field and thermal demagnetization data for several grains that demonstrate the performance of this technique. In addition, we compare scanning SQUID microscopy data with net moment measurements of the same samples performed by a commercial superconducting rock magnetometer. The results agree for stronger moments, as expected, but rapidly diverge as net moments fall below the lower 10^-10 Am2 range. These studies underscore the inability of conventional instruments not only to detect very weak moments but also to isolate contamination originating from background sources such as sample holders and mounts. We expect ultra-high sensitivity moment magnetometry using scanning SQUID microscopy will be a powerful tool in helping elucidate the formation of the solar system and planetary history.

  15. Towards high-sensitivity and high-resolution submillimeter-wave video imaging

    NASA Astrophysics Data System (ADS)

    Heinz, Erik; May, Torsten; Born, Detlef; Zieger, Gabriel; Anders, Solveig; Zakosarenko, Viatcheslav; Schubert, Marco; Krause, Torsten; Krüger, André; Schulz, Marco; Meyer, Hans-Georg

    2011-05-01

    Against a background of newly emerged security threats the well-established idea of utilizing submillimeter-wave radiation for personal security screening applications has recently evolved into a promising technology. Possible application scenarios demand sensitive, fast, flexible and high-quality imaging techniques. At present, best results are obtained by passive imaging using cryogenic microbolometers as radiation detectors. Building upon the concept of a passive submillimeter-wave stand-off video camera introduced previously, we present the evolution of this concept in a practical application-ready imaging device. This has been achieved using a variety of measures such as optimizing the detector parameters, improving the scanning mechanism, increasing the sampling speed, and enhancing the camera software. The image generation algorithm has been improved and an automatic sensor calibration technique has been implemented taking advantage of redundancy in the sensor data. The concept is based on a Cassegrain-type mirror optics, an opto-mechanical scanner providing spiraliform scanning traces, and an array of 20 superconducting transition-edge sensors (TES) operated at a temperature of 450-650 mK. The TES are cooled by a closed-cycle cooling system and read out by superconducting quantum interference devices (SQUIDs). The frequency band of operation centers around 350 GHz. The camera can operate at an object distance of 7-10 m. At 9m distance it covers a field of view of 110 cm diameter, achieves a spatial resolution of 2 cm and a pixel NETD (noise equivalent temperature difference) of 0.1-0.4 K. The maximum frame rate is 10 frames per second.

  16. High sensitivity charge amplifier for ion beam uniformity monitor

    DOEpatents

    Johnson, Gary W.

    2001-01-01

    An ion beam uniformity monitor for very low beam currents using a high-sensitivity charge amplifier with bias compensation. The ion beam monitor is used to assess the uniformity of a raster-scanned ion beam, such as used in an ion implanter, and utilizes four Faraday cups placed in the geometric corners of the target area. Current from each cup is integrated with respect to time, thus measuring accumulated dose, or charge, in Coulombs. By comparing the dose at each corner, a qualitative assessment of ion beam uniformity is made possible. With knowledge of the relative area of the Faraday cups, the ion flux and areal dose can also be obtained.

  17. High-Sensitivity Measurement of Density by Magnetic Levitation.

    PubMed

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density <10(-4) g/cm(3) for macroscopic objects (>mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects. PMID:26815205

  18. Highly sensitive electronically modulated photoacoustic spectrometer for ozone detection.

    PubMed

    Gondal, M A; Yamani, Z H

    2007-10-10

    An ozone (O(3)) gas sensor with a sensitivity of parts per 10(9) (ppb) level and a high level of selectivity based on the resonant photoacoustic effect was developed using an electronically modulated cw CO(2) laser beam. Quite different from the standard chopper modulation of a laser beam, here the laser source was electronically modulated to overcome the inherent problem of frequency instability associated with chopper modulation. With electronic modulation, in conjunction with the fast Fourier transform (FFT) of transient signals, we were able to improve significantly the sensitivity of the photoacoustic (PA) system for the detection of O(3). In addition to the improved sensitivity, our method proved that the FFT of a laser modulated PA signal could suppress the noise signal generated by spurious window diffused absorption, which in the case of most commonly used lock-in techniques is rather unavoidable. The dependence of the PA signal on various experimental parameters such as buffer gas, laser power, modulation frequency, and trace gas concentration was investigated. In the case of buffer gas, argon proved to be more suitable than nitrogen and helium in terms of enhancing the sensitivity of the system. The limits of detection of O(3) using the 9 P(14) CO(2) laser line in our PA system are 5 parts per 10(9) by volume (ppbv) and 14 ppbv with electronic and standard chopper modulation, respectively. This detection limit of O(3) is quite applicable for detection of safe levels of O(3), at ground level. PMID:17932514

  19. High-Sensitivity Measurement of Density by Magnetic Levitation.

    PubMed

    Nemiroski, Alex; Kumar, A A; Soh, Siowling; Harburg, Daniel V; Yu, Hai-Dong; Whitesides, George M

    2016-03-01

    This paper presents methods that use Magnetic Levitation (MagLev) to measure very small differences in density of solid diamagnetic objects suspended in a paramagnetic medium. Previous work in this field has shown that, while it is a convenient method, standard MagLev (i.e., where the direction of magnetization and gravitational force are parallel) cannot resolve differences in density <10(-4) g/cm(3) for macroscopic objects (>mm) because (i) objects close in density prevent each other from reaching an equilibrium height due to hard contact and excluded volume, and (ii) using weaker magnets or reducing the magnetic susceptibility of the medium destabilizes the magnetic trap. The present work investigates the use of weak magnetic gradients parallel to the faces of the magnets as a means of increasing the sensitivity of MagLev without destabilization. Configuring the MagLev device in a rotated state (i.e., where the direction of magnetization and gravitational force are perpendicular) relative to the standard configuration enables simple measurements along the axes with the highest sensitivity to changes in density. Manipulating the distance of separation between the magnets or the lengths of the magnets (along the axis of measurement) enables the sensitivity to be tuned. These modifications enable an improvement in the resolution up to 100-fold over the standard configuration, and measurements with resolution down to 10(-6) g/cm(3). Three examples of characterizing the small differences in density among samples of materials having ostensibly indistinguishable densities-Nylon spheres, PMMA spheres, and drug spheres-demonstrate the applicability of rotated Maglev to measuring the density of small (0.1-1 mm) objects with high sensitivity. This capability will be useful in materials science, separations, and quality control of manufactured objects.

  20. Does Homogeneous Ability Grouping for High School Honors English Instruction Benefit the High Achiever?

    ERIC Educational Resources Information Center

    Hostetter, Douglas Paul

    2013-01-01

    Public schools are examining their policies and instructional practices to address the achievement gap exposed by the reporting requirements of NCLB (Wenglinski, 2004). As accountability measures and stakes rise, there is a call for an improved use of scientific evidence to inform educational policymaking (Wiseman, 2010). In terms of the…

  1. Sensitive and selective tumor imaging with novel and highly activatable fluorescence strategies

    NASA Astrophysics Data System (ADS)

    Urano, Yasuteru

    2008-02-01

    Nowadays, several tumor imaging modalities such as MRI, PET and fluorescence imaging techniques have been extensively investigated. One of the central problems associated with these conventional tumor-targeted imaging methods, however, is the fact that the signal contrast between tumor and surrounding tissues relies on the efficient targeting to the tumor and the rapid sequestration or excretion of unbound agent. Among these modalities, only fluorescence imaging technique has a significant feature, in that great signal activation could be achieved which potentially leads to the selective imaging of cancer with higher tumor-to-background ratio. In this symposium, I will present some examples of fluorescence cancer imaging based on highly activatable strategies with using precisely designed novel fluorescence probes. Recently, we developed highly sensitive fluorescence probes for β-galactosidase which is applicable for living cell system. By utilizing these probes, we could establish a novel and highly activatable strategy for sensitive and selective optical imaging of imbedded tumor in the peritoneum. We took a two step procedure in that a lectin is used to localize β-galactosidase to cancer cells as an activating enzyme, and subsequent administration of a highly-sensitive fluorescence probe for the enzyme have afforded remarkable fluorescence activation selectively in tumor mass. Since the tumor-targeted enzyme can catalyze numerous substrate turnovers, a great number of fluorescent molecules could be produced and hence the rapid and sensitive detection of tumor in vivo with high tumor-to-background ratio could be achieved. Moreover, the consequent close-up investigation using fluorescence microscopy revealed that cancer microfoci as small as 200 μm could be successfully visualized.

  2. Patterns of Self-Regulation: Patterns of Self-Regulatory Strategy Use among Low-Achieving and High-Achieving University Students

    ERIC Educational Resources Information Center

    Ruban, Lilia; Reis, Sally M.

    2006-01-01

    The present mixed-methods study attempts to provide insights into the nature, idiosyncrasies, and inter- and intra-individual patterns of academic self-regulatory strategy use among two different populations of university students. Low-achieving (n = 49) and high-achieving students (n = 131) described their self-regulatory strategy use in their…

  3. Factors That Influence School Board Actions to Support Student Achievement: A Multi-Case Study of High-Achieving Rural School Districts

    ERIC Educational Resources Information Center

    Timm, Colleen A.

    2012-01-01

    The purpose of this study is to examine the factors that influence the actions taken by school boards that advance student achievement in high-achieving rural public school districts. Much of what is discussed in the literature on school improvement efforts is centered on the work carried out by school personnel at the school level. What is…

  4. Toward high-sensitivity and high-resolution submillimeter-wave video imaging

    NASA Astrophysics Data System (ADS)

    Heinz, Erik; May, Torsten; Born, Detlef; Zieger, Gabriel; Thorwirth, Günter; Anders, Solveig; Zakosarenko, Vyacheslav; Krause, Torsten; Krüger, André; Schulz, Marco; Meyer, Hans-Georg; Schubert, Marco; Starkloff, Michael

    2011-11-01

    Against a background of newly emerged security threats, the well-established idea of utilizing submillimeter-wave radiation for personal security screening applications has recently evolved into a promising technology. Possible application scenarios demand sensitive, fast, flexible and high-quality imaging techniques. At present, best results are obtained by passive imaging using cryogenic microbolometers as radiation detectors. Building upon the concept of a passive submillimeter-wave stand-off video camera introduced previously, we present the evolution of this concept into a practical application-ready imaging device. This has been achieved using a variety of measures such as optimizing the detector parameters, improving the scanning mechanism, increasing the sampling speed, and enhancing the image generation software. The camera concept is based on a Cassegrain-type mirror optics, an optomechanical scanner, an array of 20 superconducting transition-edge sensors operated at a temperature of 450 to 650 mK, and a closed-cycle cryogen-free cooling system. The main figures of the system include: a frequency band of 350+/-40 GHz, an object distance of 7 to 10 m, a circular field of view of 1.05 m diameter, and a spatial resolution in the image center of 2 cm at 8.5 m distance, a noise equivalent temperature difference of 0.1 to 0.4 K, and a maximum frame rate of 10 Hz.

  5. High-throughput, Highly Sensitive Analyses of Bacterial Morphogenesis Using Ultra Performance Liquid Chromatography.

    PubMed

    Desmarais, Samantha M; Tropini, Carolina; Miguel, Amanda; Cava, Felipe; Monds, Russell D; de Pedro, Miguel A; Huang, Kerwyn Casey

    2015-12-25

    The bacterial cell wall is a network of glycan strands cross-linked by short peptides (peptidoglycan); it is responsible for the mechanical integrity of the cell and shape determination. Liquid chromatography can be used to measure the abundance of the muropeptide subunits composing the cell wall. Characteristics such as the degree of cross-linking and average glycan strand length are known to vary across species. However, a systematic comparison among strains of a given species has yet to be undertaken, making it difficult to assess the origins of variability in peptidoglycan composition. We present a protocol for muropeptide analysis using ultra performance liquid chromatography (UPLC) and demonstrate that UPLC achieves resolution comparable with that of HPLC while requiring orders of magnitude less injection volume and a fraction of the elution time. We also developed a software platform to automate the identification and quantification of chromatographic peaks, which we demonstrate has improved accuracy relative to other software. This combined experimental and computational methodology revealed that peptidoglycan composition was approximately maintained across strains from three Gram-negative species despite taxonomical and morphological differences. Peptidoglycan composition and density were maintained after we systematically altered cell size in Escherichia coli using the antibiotic A22, indicating that cell shape is largely decoupled from the biochemistry of peptidoglycan synthesis. High-throughput, sensitive UPLC combined with our automated software for chromatographic analysis will accelerate the discovery of peptidoglycan composition and the molecular mechanisms of cell wall structure determination.

  6. High frequency wide-band transformer uses coax to achieve high turn ratio and flat response

    NASA Technical Reports Server (NTRS)

    De Parry, T.

    1966-01-01

    Center-tap push-pull transformer with toroidal core helically wound with a single coaxial cable creates a high frequency wideband transformer. This transformer has a high-turn ratio, a high coupling coefficient, and a flat broadband response.

  7. High pressure-sensitive gene expression in Lactobacillus sanfranciscensis.

    PubMed

    Vogel, R F; Pavlovic, M; Hörmann, S; Ehrmann, M A

    2005-08-01

    Lactobacillus sanfranciscensis is a Gram-positive lactic acid bacterium used in food biotechnology. It is necessary to investigate many aspects of a model organism to elucidate mechanisms of stress response, to facilitate preparation, application and performance in food fermentation, to understand mechanisms of inactivation, and to identify novel tools for high pressure biotechnology. To investigate the mechanisms of the complex bacterial response to high pressure we have analyzed changes in the proteome and transcriptome by 2-D electrophoresis, and by microarrays and real time PCR, respectively. More than 16 proteins were found to be differentially expressed upon high pressure stress and were compared to those sensitive to other stresses. Except for one apparently high pressure-specific stress protein, no pressure-specific stress proteins were found, and the proteome response to pressure was found to differ from that induced by other stresses. Selected pressure-sensitive proteins were partially sequenced and their genes were identified by reverse genetics. In a transcriptome analysis of a redundancy cleared shot gun library, about 7% of the genes investigated were found to be affected. Most of them appeared to be up-regulated 2- to 4-fold and these results were confirmed by real time PCR. Gene induction was shown for some genes up-regulated at the proteome level (clpL/groEL/rbsK), while the response of others to high hydrostatic pressure at the transcriptome level seemed to differ from that observed at the proteome level. The up-regulation of selected genes supports the view that the cell tries to compensate for pressure-induced impairment of translation and membrane transport. PMID:16082466

  8. Effects of a Collaborative Science Intervention on High Achieving Students' Learning Anxiety and Attitudes toward Science

    NASA Astrophysics Data System (ADS)

    Hong, Zuway-R.

    2010-10-01

    This study investigated the effects of a collaborative science intervention on high achieving students' learning anxiety and attitudes toward science. Thirty-seven eighth-grade high achieving students (16 boys and 21 girls) were selected as an experimental group who joined a 20-week collaborative science intervention, which integrated and utilized an innovative teaching strategy. Fifty-eight eighth-grade high achieving students were selected as the comparison group. The Secondary School Student Questionnaire was conducted to measure all participants' learning anxiety and attitudes toward science. In addition, 12 target students from the experimental group (i.e., six active and six passive students) were recruited for weekly classroom observations and follow-up interviews during the intervention. Both quantitative and qualitative findings revealed that experimental group students experienced significant impact as seen through increased attitudes and decreased anxiety of learning science. Implications for practice and research are provided.

  9. ALMA: Millimeter/submillimeter Astronomy at high sensitivity and resolution

    NASA Astrophysics Data System (ADS)

    Wootten, Alwyn; Corder, Stuartt Alan; Iono, Daisuke; Testi, Leonardo

    2015-08-01

    Vigorous and transformative investigation of the millimeter/submillimeter sky at high sensitivity and high resolution has benefitted from the recent completion of the Atacama Large Millimeter/submillimeter Array (ALMA), an effort of 22 countries. ALMA, a versatile interferometric telescope at 5000m elevation in the Atacama Desert of northern Chile, is comprised of sixty-six precision telescopes which may be arrayed over a 16 km extent on the high Chajnantor plain. Owing to its large collecting area of over 6600m^2 and its commodious spectral grasp of 8 GHz of spectrum in dual polarizations within an 84-950 GHz range, ALMA provides astronomers with vastly improved spectroscopic sensitivity. Spatial resolutions of 30 milliarcsec were demonstrated recently, revealing rings within the HL Tau protoplanetary disk, the rotating structure of the asteroid Juno and the molecular structure of the z~3 lensed galaxy SDP.81. The astrometric accuracy even at this early stage of deployment is better than 3 milliarcsec, providing improved ephemerides for the encounter of the New Horizons spacecraft with the Pluto-Charon system. Very long baseline capability is expected to bring microarcsecond imaging to a worldwide array anchored by ALMA with potential for imaging nearby Black Holes on the scales of their Event Horizons.ALMA's huge collecting area has enabled detection of lines of C, N and CO and continuum for characterization of massive complexes near the Era of Recombination. ALMA's sensitivity and resolution have enabledmeasurement of molecular emission through cosmic time from numerous molecules characterizing galactic star-forming regions and tracing their kinematics near active nuclei, starbursts, interacting clouds and quiescent disks. ALMA's sensitivity, resolution and spectral grasp have enabled it to image molecules and dust characterizing circumstellar disks and embedded bodies in protostellar, transition and debris stages of development.ALMA is a partnership of ESO

  10. School factors affecting postsecondary career pursuits of high-achieving girls in mathematics and science

    NASA Astrophysics Data System (ADS)

    Yoo, Hyunsil

    This study examined the influences of secondary school experiences of high-achieving girls in math and science on their postsecondary career pursuits in science fields. Specifically, using the National Education Longitudinal Study of 1988 (NELS:88), the study investigated how science class experiences in high school affect science career persistence of high-achieving girls over and above personal and family factors. Selecting the top 10% on the 8 th grade math and science achievement tests from two panel samples of 1988--1994 and 1988--2000, this study examined which science instructional experiences (i.e., lecture-oriented, experiment-oriented, and student-oriented) best predicted college major choices and postsecondary degree attainments in the fields of science after controlling for personal and family factors. A two-stage test was employed for the analysis of each panel sample. The first test examined the dichotomous career pursuits between science careers and non-science careers and the second test examined the dichotomous pursuits within science careers: "hard" science and "soft" science. Logistic regression procedures were used with consideration of panel weights and design effects. This study identified that experiment-oriented and student-oriented instructional practices seem to positively affect science career pursuits of high-achieving females, while lecture-oriented instruction negatively affected their science career pursuits, and that the longitudinal effects of the two positive instructional contributors to science career pursuits appear to be differential between major choice and degree attainment. This study also found that the influences of instructional practices seem to be slight for general females, while those for high-achieving females were highly considerable, regardless of whether negative or positive. Another result of the study found that only student-oriented instruction seemed to have positive effects for high-achieving males. In

  11. Coumarin-bearing triarylamine sensitizers with high molar extinction coefficient for dye-sensitized solar cells

    NASA Astrophysics Data System (ADS)

    Zhong, Changjian; Gao, Jianrong; Cui, Yanhong; Li, Ting; Han, Liang

    2015-01-01

    Coumarin unit is introduced into triarylamine and three organic sensitizers are designed and synthesized with triarylamine bearing coumarin moiety as the electron donor, conjugated system containing thiophene unit as the π-bridge, and cyanoacetic acid moiety as the electron acceptor. The light-harvesting capabilities and photovoltaic performance of these dyes are investigated systematically with the comparison of different π-bridges. High molar extinction coefficients are observed in these triarylamine dyes and the photocurrent and photovoltage are increased with the introduction of another thiophene or benzene. Optimal photovoltaic performance (η = 6.24%, Voc = 690 mV, Jsc = 14.33 mA cm-2, and ff = 0.63) is observed in the DSSC based on dye with thiophene-phenyl unit as the π-conjugated bridge under 100 mW cm-2 simulated AM 1.5 G solar irradiation.

  12. High sensitivity resonance frequency measurements of individualmicro-cantilevers using fiber optical interferometry

    SciTech Connect

    Duden, Thomas; Radmilovic, Velimir

    2009-03-04

    We describe a setup for the resonance frequency measurement of individual microcantilevers. The setup displays both high spatial selectivity and sensitivity to specimen vibrations by utilizing a tapered uncoated fiber tip. The high sensitivity to specimen vibrations is achieved by the combination of optical Fabry-Perot interferometry and narrow band RF detection. Wave fronts reflected on the specimen and on the fiber tip end face interfere, thus no reference plane on the specimen is needed, as demonstrated with the example of freestanding silicon nitride micro-cantilevers. The resulting system is integrated in a DB-235 dual beam FIB system, thereby allowing the measurement of micro-cantilever responses during observation in SEM mode. The FIB was used to modify the optical fiber tip. At this point of our RF system development, the microcantilevers used to characterize the detector were not modified in situ.

  13. High-sensitivity acoustic sensors from nanofibre webs

    PubMed Central

    Lang, Chenhong; Fang, Jian; Shao, Hao; Ding, Xin; Lin, Tong

    2016-01-01

    Considerable interest has been devoted to converting mechanical energy into electricity using polymer nanofibres. In particular, piezoelectric nanofibres produced by electrospinning have shown remarkable mechanical energy-to-electricity conversion ability. However, there is little data for the acoustic-to-electric conversion of electrospun nanofibres. Here we show that electrospun piezoelectric nanofibre webs have a strong acoustic-to-electric conversion ability. Using poly(vinylidene fluoride) as a model polymer and a sensor device that transfers sound directly to the nanofibre layer, we show that the sensor devices can detect low-frequency sound with a sensitivity as high as 266 mV Pa−1. They can precisely distinguish sound waves in low to middle frequency region. These features make them especially suitable for noise detection. Our nanofibre device has more than five times higher sensitivity than a commercial piezoelectric poly(vinylidene fluoride) film device. Electrospun piezoelectric nanofibres may be useful for developing high-performance acoustic sensors. PMID:27005010

  14. High-sensitivity acoustic sensors from nanofibre webs.

    PubMed

    Lang, Chenhong; Fang, Jian; Shao, Hao; Ding, Xin; Lin, Tong

    2016-01-01

    Considerable interest has been devoted to converting mechanical energy into electricity using polymer nanofibres. In particular, piezoelectric nanofibres produced by electrospinning have shown remarkable mechanical energy-to-electricity conversion ability. However, there is little data for the acoustic-to-electric conversion of electrospun nanofibres. Here we show that electrospun piezoelectric nanofibre webs have a strong acoustic-to-electric conversion ability. Using poly(vinylidene fluoride) as a model polymer and a sensor device that transfers sound directly to the nanofibre layer, we show that the sensor devices can detect low-frequency sound with a sensitivity as high as 266 mV Pa(-1). They can precisely distinguish sound waves in low to middle frequency region. These features make them especially suitable for noise detection. Our nanofibre device has more than five times higher sensitivity than a commercial piezoelectric poly(vinylidene fluoride) film device. Electrospun piezoelectric nanofibres may be useful for developing high-performance acoustic sensors. PMID:27005010

  15. High Sensitivity, Low Volume Method to Determine Dissolved Phosphorus

    NASA Astrophysics Data System (ADS)

    Haberer, J. L.; Brandes, J. A.

    2001-12-01

    A high sensitivity, low volume method was developed to determine nanomolar concentrations of soluble reactive phosphorus (SRP) using reverse phase HPLC. The technique in determining SRP involved using methods from Strickland and Parsons, 1972 and Karl and Tien, 1992. Various techniques for improving blanks and sensitivity will be discussed. The method was applied to seawater and freshwater samples taken from the estuarine Nueces Delta system, Texas, two sites in the Gulf of Mexico, and within two upland (2400 m) forest catchments in the Peruvian Andes. One catchment was partially deforested within the last 3 years, while the other has remained untouched. Samples in the Gulf of Mexico were taken at a series of coastal and open water stations at various depths. Samples in each of the two upland forest catchments in Peru were obtained at 33.3 m distance intervals along a 100 m reach. Samples were taken in the Nueces River, Texas upland from a marsh estuary and from high and low regions of the marsh. Comparisons are made between the forest catchment sites in addition to comparisons made in the Nueces marsh estuary/river system. Depth profiles of SRP in the Gulf of Mexico are established. Future studies should be conducted to investigate phosphate in sediment pore waters. This method has many potential applications, is scalable across a wide range of sample volumes, and can be automated.

  16. Development of a Highly Sensitive Cell-Based Assay for Detecting Botulinum Neurotoxin Type A through Neural Culture Media Optimization.

    PubMed

    Hong, Won S; Pezzi, Hannah M; Schuster, Andrea R; Berry, Scott M; Sung, Kyung E; Beebe, David J

    2016-01-01

    Botulinum neurotoxin (BoNT) is the most lethal naturally produced neurotoxin. Due to the extreme toxicity, BoNTs are implicated in bioterrorism, while the specific mechanism of action and long-lasting effect was found to be medically applicable in treating various neurological disorders. Therefore, for both public and patient safety, a highly sensitive, physiologic, and specific assay is needed. In this paper, we show a method for achieving a highly sensitive cell-based assay for BoNT/A detection using the motor neuron-like continuous cell line NG108-15. To achieve high sensitivity, we performed a media optimization study evaluating three commercially available neural supplements in combination with retinoic acid, purmorphamine, transforming growth factor β1 (TGFβ1), and ganglioside GT1b. We found nonlinear combinatorial effects on BoNT/A detection sensitivity, achieving an EC50 of 7.4 U ± 1.5 SD (or ~7.9 pM). The achieved detection sensitivity is comparable to that of assays that used primary and stem cell-derived neurons as well as the mouse lethality assay.

  17. Highly sensitive detection of urinary cadmium to assess personal exposure.

    PubMed

    Argun, Avni A; Banks, Ashley M; Merlen, Gwendolynne; Tempelman, Linda A; Becker, Michael F; Schuelke, Thomas; Dweik, Badawi M

    2013-04-22

    A series of Boron-Doped Diamond (BDD) ultramicroelectrode arrays were fabricated and investigated for their performance as electrochemical sensors to detect trace level metals such as cadmium. The steady-state diffusion behavior of these sensors was validated using cyclic voltammetry followed by electrochemical detection of cadmium in water and in human urine to demonstrate high sensitivity (>200 μA ppb(-1) cm(-2)) and low background current (<4 nA). When an array of ultramicroelectrodes was positioned with optimal spacing, these BDD sensors showed a sigmoidal diffusion behavior. They also demonstrated high accuracy with linear dose dependence for quantification of cadmium in a certified reference river water sample from the U.S. National Institute of Standards and Technology (NIST) as well as in a human urine sample spiked with 0.25-1 ppb cadmium. PMID:23561905

  18. Highly sensitive thermal detection of thrombin using aptamer-functionalized phase change nanoparticles.

    PubMed

    Wang, Chaoming; Hossain, Mainul; Ma, Liyuan; Ma, Zeyu; Hickman, James J; Su, Ming

    2010-10-15

    This paper describes a novel thermal biosensing technique for the highly sensitive and selective detection of thrombin using RNA aptamer-functionalized phase change nanoparticles as thermal probes. The presence of thrombin in solution leads to attachment of nanoparticles onto a substrate modified with the same aptamer by forming sandwiched complexes. The phase changes of nanoparticles from solid to liquid adsorb heat energy and generate sharp melting peaks during linear temperature scans, where the positions and areas of the melting peaks reflect the presence and the amount of thrombin, respectively. A detection sensitivity of 22 nM is achieved on flat aluminum surfaces, and the sensitivity can be enhanced by four times using silicon nanopillar substrates that have higher surface area. The thermal detection is immune to colored species in solution and has been used directly to detect thrombin in serum samples. By combining the high specificity of aptamers and the large surface area of silicon nanostructures, the thermal signals obtained during phase change of nanoparticles provide a highly sensitive, selective and low-cost method for thrombin detection.

  19. Novel near-infrared carboxylated 1,3-indandione sensitizers for highly efficient flexible dye-sensitized solar cells.

    PubMed

    Shibayama, Naoyuki; Inoue, Yukiko; Abe, Masahiro; Kajiyama, Shingo; Ozawa, Hironobu; Miura, Hidetoshi; Arakawa, Hironori

    2015-08-18

    Three novel metal-free organic dyes (DN458, DN475 and DN484) were designed for use in plastic-substrate dye-sensitized solar cells (PDSCs). The photoelectric conversion region of DN475 was successfully expanded into the near-infrared region. As a result, an energy conversion efficiency of 5.76% was achieved.

  20. Novel near-infrared carboxylated 1,3-indandione sensitizers for highly efficient flexible dye-sensitized solar cells.

    PubMed

    Shibayama, Naoyuki; Inoue, Yukiko; Abe, Masahiro; Kajiyama, Shingo; Ozawa, Hironobu; Miura, Hidetoshi; Arakawa, Hironori

    2015-08-18

    Three novel metal-free organic dyes (DN458, DN475 and DN484) were designed for use in plastic-substrate dye-sensitized solar cells (PDSCs). The photoelectric conversion region of DN475 was successfully expanded into the near-infrared region. As a result, an energy conversion efficiency of 5.76% was achieved. PMID:26166712

  1. Highly sensitive multi-core flat fiber surface plasmon resonance refractive index sensor.

    PubMed

    Rifat, Ahmmed A; Mahdiraji, G A; Sua, Yong Meng; Ahmed, Rajib; Shee, Y G; Adikan, F R Mahamd

    2016-02-01

    A simple multi-core flat fiber (MCFF) based surface plasmon resonance (SPR) sensor operating in telecommunication wavelengths is proposed for refractive index sensing. Chemically stable gold (Au) and titanium dioxide (TiO(2)) layers are used outside the fiber structure to realize a simple detection mechanism. The modeled sensor shows average wavelength interrogation sensitivity of 9,600 nm/RIU (Refractive Index Unit) and maximum sensitivity of 23,000 nm/RIU in the sensing range of 1.46-1.485 and 1.47-1.475, respectively. Moreover, the refractive index resolution of 4.35 × 10(-6) is demonstrated. Additionally, proposed sensor had shown the maximum amplitude interrogation sensitivity of 820 RIU(-1), with the sensor resolution of 1.22 × 10(-5) RIU. To the best of our knowledge, the proposed sensor achieved the highest wavelength interrogation sensitivity among the reported fiber based SPR sensors. Finally we anticipate that, this novel and highly sensitive MCFF SPR sensor will find the potential applications in real time remote sensing and monitoring, ultimately enabling inexpensive and accurate chemical and biochemical analytes detection. PMID:26906823

  2. Highly sensitive multi-core flat fiber surface plasmon resonance refractive index sensor.

    PubMed

    Rifat, Ahmmed A; Mahdiraji, G A; Sua, Yong Meng; Ahmed, Rajib; Shee, Y G; Adikan, F R Mahamd

    2016-02-01

    A simple multi-core flat fiber (MCFF) based surface plasmon resonance (SPR) sensor operating in telecommunication wavelengths is proposed for refractive index sensing. Chemically stable gold (Au) and titanium dioxide (TiO(2)) layers are used outside the fiber structure to realize a simple detection mechanism. The modeled sensor shows average wavelength interrogation sensitivity of 9,600 nm/RIU (Refractive Index Unit) and maximum sensitivity of 23,000 nm/RIU in the sensing range of 1.46-1.485 and 1.47-1.475, respectively. Moreover, the refractive index resolution of 4.35 × 10(-6) is demonstrated. Additionally, proposed sensor had shown the maximum amplitude interrogation sensitivity of 820 RIU(-1), with the sensor resolution of 1.22 × 10(-5) RIU. To the best of our knowledge, the proposed sensor achieved the highest wavelength interrogation sensitivity among the reported fiber based SPR sensors. Finally we anticipate that, this novel and highly sensitive MCFF SPR sensor will find the potential applications in real time remote sensing and monitoring, ultimately enabling inexpensive and accurate chemical and biochemical analytes detection.

  3. "It's a Way of Life for Us": High Mobility and High Achievement in Department of Defense Schools.

    ERIC Educational Resources Information Center

    Smrekar, Claire E.; Owens, Debra E.

    2003-01-01

    Examines the academic performance of students in U.S. Department of Defense Education Activity (DoDEA) schools, which have high student mobility. Some observers contend that these students' high achievement is a function of their middle class family and community characteristics. Asserts that DoDEA schools simultaneously "do the right things" and…

  4. Highly Sensitive Nanoparticle-based Multifunctional Biosensor for Antigen Detection

    NASA Astrophysics Data System (ADS)

    Siavoshi, Salome

    Precise and selective positioning of nanoparticles gives rise to many applications where assembly of nano building blocks with different biological or chemical functionalization is necessary. One remarkable application is the simultaneous early detection of multiple biomarkers in the field of miniaturized multiplex biosensors. To enable multiplex detection of antigens, nanoparticles with various antibody coatings can be selectively assembled in trenches on different regions on a biochip so that they bind selectively to the specific antigen of interest. The presented work utilizes electric field assisted assembly techniques to assemble nanoparticles with various surface functionalization and coatings. Nanoparticles are assembled into pre-fabricated via and trench patterns generated on a PMMA coated gold surface, using electron-beam lithography. Two techniques have been developed for selective assembly of nanoparticles: sequential size-selective directed assembly and sequential site-selective assembly. Both selective assembly techniques provide fast and reproducible assembly over large areas while achieving high yield. The sequential size-selective assembly is a template-assisted technique where the selectivity is achieved by controlling the size of the nanopatterns and the size of the nanoparticles. The possibility of particle detachment and the factors affecting the sorting efficiency for this technique is studied. We show that a complete sorting can be achieved when the size of the vias is close to the diameter of the nanoparticles and the size distribution of the chosen nanoparticles do not overlap. In the site-selective assembly, the selectivity is achieved by having electrically isolated sites (regions) on the same chip. Electrophoresis is performed for each region in a step by step process. Selective assembly results, for up to four nanoparticles with various coating/functionalization are presented using the site-selective assembly technique. We use the

  5. Luminescent Lanthanide Reporters for High-Sensitivity Novel Bioassays.

    SciTech Connect

    Anstey, Mitchell R.; Fruetel, Julia A.; Foster, Michael E.; Hayden, Carl C.; Buckley, Heather L.; Arnold, John

    2013-09-01

    Biological imaging and assay technologies rely on fluorescent organic dyes as reporters for a number of interesting targets and processes. However, limitations of organic dyes such as small Stokes shifts, spectral overlap of emission signals with native biological fluorescence background, and photobleaching have all inhibited the development of highly sensitive assays. To overcome the limitations of organic dyes for bioassays, we propose to develop lanthanide-based luminescent dyes and demonstrate them for molecular reporting applications. This relatively new family of dyes was selected for their attractive spectral and chemical properties. Luminescence is imparted by the lanthanide atom and allows for relatively simple chemical structures that can be tailored to the application. The photophysical properties offer unique features such as narrow and non-overlapping emission bands, long luminescent lifetimes, and long wavelength emission, which enable significant sensitivity improvements over organic dyes through spectral and temporal gating of the luminescent signal.Growth in this field has been hindered due to the necessary advanced synthetic chemistry techniques and access to experts in biological assay development. Our strategy for the development of a new lanthanide-based fluorescent reporter system is based on chelation of the lanthanide metal center using absorbing chromophores. Our first strategy involves "Click" chemistry to develop 3-fold symmetric chelators and the other involves use of a new class of tetrapyrrole ligands called corroles. This two-pronged approach is geared towards the optimization of chromophores to enhance light output.

  6. Highly sensitive flow-injection chemiluminescence determination of pyrogallol compounds

    NASA Astrophysics Data System (ADS)

    Kanwal, Shamsa; Fu, Xiaohong; Su, Xingguang

    2009-12-01

    A highly sensitive flow-injection chemiluminescent method for the direct determination of pyrogallol compounds has been developed. Proposed method is based on the enhanced effect of pyrogallol compounds on the chemiluminescence signals of KMnO 4-H 2O 2 system in slightly alkaline medium. Three important pyrogallol compounds, pyrogallic acid, gallic acid and tannic acid, have been detected by this method, and the possible mechanism of the CL reaction is also discussed. The proposed method is simple, convenient, rapid (60 samples h -1), and sensitive, has a linear range of 8 × 10 -10 mol L -1 to 1 × 10 -5 mol L -1, for pyrogallic acid, with a detection limit of 6 × 10 -11 mol L -1, 4 × 10 -8 mol L -1 to 5 × 10 -3 mol L -1 for gallic acid with a detection limit of 9 × 10 -10 mol L -1, and 8 × 10 -8 mol L -1 to 5 × 10 -2 mol L -1 for tannic acid, with a detection limit of 2 × 10 -9 mol L -1, respectively. The relative standard deviation (RSD, n = 15) was 0.8, 1.1 and 1.3% for 5 × 10 -6 mol L -1 pyrogallic acid, gallic acid and tannic acid, respectively. The proposed method was successfully applied to the determination of pyrogallol compounds in tea and coffee samples.

  7. High sensitivity tracking of CD-SEM performance: QSEM

    NASA Astrophysics Data System (ADS)

    Babin, S.; Huang, Jaffee; Yushmanov, P.

    2015-03-01

    The performance of CD-SEMs directly affects the measured values of critical dimensions (CDs) at the time of their measurement. Tracking the performance of CD-SEMs is necessary to establish trust in their results and provide guidance for preventive maintenance and tune-ups. When the measured CDs are out of specification in manufacturing, it is crucial to determine whether this is due to process variation or the metrology tool itself. Multiple methods that use linewidth measurements have been employed thus far; however, they suffer from linewidth variations on the wafer, as well as from variations of line edge and linewidth roughness. Here, we report a method that is capable of providing a quantitative extraction of the SEM performance based on advanced algorithms. The method is independent of linewidth, line edge roughness and linewidth roughness, and has high sensitivity. This software, QSEM, was developed to automatically evaluate image quality and assign a value to that quality. The image quality value is based on multiple factors such as noise, sharpness, analysis of histograms, and contrast. The sensitivity of the software was evaluated; a good correlation between image quality results and linewidth variation due to SEM performance was established. Using QSEM to analyze SEM images allows the performance of CDSEMs to be tracked for proper calibration and preventive maintenance, as well as to resolve the dispute between failure in the process or the metrology.

  8. High sensitivity permeation measurement system for 'ultrabarrier' thin films

    SciTech Connect

    Zhang Xiaodong; Lewis, Jay S.; Wolter, Scott D.; Parker, Charles B.; Glass, Jeffrey T.

    2007-11-15

    The authors demonstrate a new technique for high sensitivity gas permeation measurements by integrating mass spectrometry with programed accumulation, detection, and evacuation of permeant. After passing through the film of interest, the gas permeant is captured and accumulated in an isolated ultrahigh vacuum (UHV) volume. The permeant is then allowed to enter an adjacent residual gas analyzer (RGA) and the resulting partial pressure increase is correlated with the steady state permeation rate. Calibrated results are given for helium and argon permeation through polymer films. The measured detection limits of the system are 1.8x10{sup -4} cm{sup 3}/m{sup 2} day for helium and 2.5x10{sup -4} cm{sup 3}/m{sup 2} day for argon. Both values are several orders of magnitude lower than what is available from commercial instruments or similar RGA-based instruments. Potential applications of this technique include measurement of oxygen and water vapor permeation with sensitivities required for assessment of ultrabarrier coatings.

  9. Kinetics of Highly Sensitive Troponin T after Cardiac Surgery.

    PubMed

    Omar, Amr S; Sudarsanan, Suraj; Hanoura, Samy; Osman, Hany; Sivadasan, Praveen C; Shouman, Yasser; Tuli, Alejandro Kohn; Singh, Rajvir; Al Khulaifi, Abdulaziz

    2015-01-01

    Perioperative myocardial infarction (PMI) confers a considerable risk in cardiac surgery settings; finding the ideal biomarker seems to be an ideal goal. Our aim was to assess the diagnostic accuracy of highly sensitive troponin T (hsTnT) in cardiac surgery settings and to define a diagnostic level for PMI diagnosis. This was a single-center prospective observational study analyzing data from all patients who underwent cardiac surgeries. The primary outcome was the diagnosis of PMI through a specific level. The secondary outcome measures were the lengths of mechanical ventilation (LOV), stay in the intensive care unit (LOSICU), and hospitalization. Based on the third universal definition of PMI, patients were divided into two groups: no PMI (Group I) and PMI (Group II). Data from 413 patients were analyzed. Nine patients fulfilled the diagnostic criteria of PMI, while 41 patients were identified with a 5-fold increase in their CK-MB (≥ 120 U/L). Using ROC analysis, a hsTnT level of 3,466 ng/L or above showed 90% sensitivity and 90% specificity for the diagnosis of PMI. Secondary outcome measures in patients with PMI were significantly prolonged. In conclusion, the hsTnT levels detected here paralleled those of CK-MB and a cut-off level of 3466 ng/L could be diagnostic of PMI. PMID:26539512

  10. Sensitivity of once-shocked, weathered high explosives

    SciTech Connect

    Williams, K.L.; Harris, B.W.

    1998-07-01

    Effects caused by stimulating once-shocked, weathered high explosives (OSW-HE) are investigated. The sensitivity of OSW-HE to mechanical stimuli was determined using standard industry tests. Some initial results are given. Pieces of OSW-HE were collected from active and inactive firing sites and from an area surrounding a drop tower at Los Alamos where skid and spigot tests were done. Samples evaluated were cast explosives or plastic bonded explosive (PBX) formulations containing cyclotrimethylenetrinitramine (RDX), cyclotetramethylene tetranitramine (HMX), 2,4,6-trinitrotoluene (TNT), mock or inert HE [tris(beta-chloroethyl)phosphate (CEF)], barium nitrate, cyanuric acid, talc, and Kel-F. Once-shocked, weathered LX-10 Livermore explosive [HMX/Viton A, (95/5 wt %)], PBX 9011 [HMX/Estane, (90/10 wt %)], PBX 9404 [HMX/nitrocellulose, tris(beta-chloroethyl) phosphate, (94/3/3 wt %)], Composition B or cyclotol (TNT/RDX explosives), and PBX 9007 (90% RDX, 9.1% styrene, 0.5% dioctyl phthalate, and 0.45 resin) were subjected to the hammer test, the drop-weight impact sensitivity test, differential thermal analysis (DTA), the spark test, the Henkin`s critical temperature test, and the flame test. Samples were subjected to remote, wet cutting and drilling; remote, liquid-nitrogen-cooled grinding and crushing; and scanning electron microscope (SEM) surface analyses for morphological changes.

  11. Nanoparticle-Structured Highly Sensitive and Anisotropic Gauge Sensors.

    PubMed

    Zhao, Wei; Luo, Jin; Shan, Shiyao; Lombardi, Jack P; Xu, Yvonne; Cartwright, Kelly; Lu, Susan; Poliks, Mark; Zhong, Chuan-Jian

    2015-09-16

    The ability to tune gauge factors in terms of magnitude and orientation is important for wearable and conformal electronics. Herein, a sensor device is described which is fabricated by assembling and printing molecularly linked thin films of gold nanoparticles on flexible microelectrodes with unusually high and anisotropic gauge factors. A sharp difference in gauge factors up to two to three orders of magnitude between bending perpendicular (B(⊥)) and parallel (B(||)) to the current flow directions is observed. The origin of the unusual high and anisotropic gauge factors is analyzed in terms of nanoparticle size, interparticle spacing, interparticle structure, and other parameters, and by considering the theoretical aspects of electron conduction mechanism and percolation pathway. A critical range of resistivity where a very small change in strain and the strain orientation is identified to impact the percolation pathway in a significant way, leading to the high and anisotropic gauge factors. The gauge anisotropy stems from molecular and nanoscale fine tuning of interparticle properties of molecularly linked nanoparticle assembly on flexible microelectrodes, which has important implication for the design of gauge sensors for highly sensitive detection of deformation in complex sensing environment or on complex curved surfaces such as wearable electronics and skin sensors.

  12. Spatial Experiences of High Academic Achievers: Insights from a Developmental Perspective

    ERIC Educational Resources Information Center

    Weckbacher, Lisa Marie; Okamoto, Yukari

    2012-01-01

    The study explored the relationship between types of spatial experiences and spatial abilities among 13- to 14-year-old high academic achievers. Each participant completed two spatial tasks and a survey assessing favored spatial activities across five categories (computers, toys, sports, music, and art) and three developmental periods (early…

  13. High-Stakes Testing and Student Achievement: Updated Analyses with NAEP Data

    ERIC Educational Resources Information Center

    Nichols, Sharon L.; Glass, Gene V.; Berliner, David C.

    2012-01-01

    The present research is a follow-up study of earlier published analyses that looked at the relationship between high-stakes testing pressure and student achievement in 25 states. Using the previously derived Accountability Pressure Index (APR) as a measure of state-level policy pressure for performance on standardized tests, a series of…

  14. Performance-Approach Goal Effects on Achievement under Low versus High Challenge Conditions

    ERIC Educational Resources Information Center

    Senko, Corwin; Durik, Amanda M.; Patel, Lily; Lovejoy, Chelsea M.; Valentiner, David

    2013-01-01

    Two studies examined the effects of university students' achievement goals on performance under low versus high challenge conditions. The first was a laboratory experiment in which participants were assigned goals to pursue on a novel mathematics task alleged to be simple or complex to use. The second was a survey study in which students set goals…

  15. Impact of Physical Environment on Academic Achievement of High School Youth.

    ERIC Educational Resources Information Center

    Burkhalter, Bettye B.

    1983-01-01

    To study the relationship of the physical environment to high school students' academic achievement, 60 students participated in an experiential career exploration program at the Alabama Space and Rocket Center while 108 students participated in a traditional careers program. Tests indicated the former group improved more in career choice…

  16. Universal Factors of Student Achievement in High-Performing Eastern and Western Countries

    ERIC Educational Resources Information Center

    Lee, Jihyun

    2014-01-01

    This study investigates whether a common set of student attitudes and behavioral tendencies can account for academic achievement across different, especially high-performing, countries via analysis of the PISA 2009 international data set. The 13 countries examined are 5 of the top-performing Eastern countries/systems, namely Shanghai China, South…

  17. The Federal Transformation Intervention Model in Persistently Lowest Achieving High Schools: A Mixed-Methods Study

    ERIC Educational Resources Information Center

    Le Patner, Michelle B.

    2012-01-01

    This study examined the American Recovery and Reinvestment Act federal mandate of the Transformation Intervention Model (TIM) outlined by the School Improvement Grant, which was designed to turn around persistently lowest achieving schools. The study was conducted in four high schools in a large Southern California urban district that selected the…

  18. Excellence in English in Middle and High School: How Teachers' Professional Lives Support Student Achievement.

    ERIC Educational Resources Information Center

    Langer, Judith A.

    The Center on English Learning and Achievement (CELA) has been studying the characteristics of successful English programs in middle and high schools. This report discusses the findings of the first two years of their 5-year Excellence in English study and focuses on the educational practices that support student literacy as well as the…

  19. Social Media Use, Loneliness, and Academic Achievement: A Correlational Study with Urban High School Students

    ERIC Educational Resources Information Center

    Neto, Roque; Golz, Nancy; Polega, Meaghan

    2015-01-01

    This study explored the association between social media use, loneliness, and academic achievement in high school students and identified the demographic characteristics associated with these three elements. This study also aimed to identify the percentage of variance in loneliness accounted for by social media use and GPA. Participants were 345…

  20. Emotional Intelligence and Academic Achievement of High School Students in Kanyakumari District

    ERIC Educational Resources Information Center

    Lawrence, A. S. Arul; Deepa, T.

    2013-01-01

    The objective of the study is to find the significant relationship between emotional intelligence and academic achievement of high school students with reference to the background variables. Survey method was employed. Two tools are used in this study namely self-made Trait Emotional Intelligence Questionnaire Short Form (TEIQue SF) and the…

  1. Conflicts and Communication between High-Achieving Chinese American Adolescents and Their Parents

    ERIC Educational Resources Information Center

    Qin, Desiree Baolian; Chang, Tzu-Fen; Han, Eun-Jin; Chee, Grace

    2012-01-01

    Drawing on in-depth interview data collected on 18 high-achieving Chinese American students, the authors examine domains of acculturation-based conflicts, parent and child internal conflicts, and conflict resolution in their families. Their analyses show that well-established negative communication patterns in educational expectations, divergent…

  2. Comparing Computer Game and Traditional Lecture Using Experience Ratings from High and Low Achieving Students

    ERIC Educational Resources Information Center

    Grimley, Michael; Green, Richard; Nilsen, Trond; Thompson, David

    2012-01-01

    Computer games are purported to be effective instructional tools that enhance motivation and improve engagement. The aim of this study was to investigate how tertiary student experiences change when instruction was computer game based compared to lecture based, and whether experiences differed between high and low achieving students. Participants…

  3. New Counter-School Cultures: Female Students' Drug Use at a High-Achieving Secondary School

    ERIC Educational Resources Information Center

    Fletcher, Adam; Bonell, Chris; Rhodes, Tim

    2009-01-01

    We draw on case-study research at a high-achieving secondary school in London to illustrate how school experiences may influence drug use and reproduce inequalities in reconstructed ways in late modernity. Qualitative data were collected through semi-structured interviews with students and teachers, and observations. We focus in particular on the…

  4. How High-Achieving African American Undergraduate Men Negotiate Cultural Challenges at a Predominantly White Institution

    ERIC Educational Resources Information Center

    Bradley, Elva Elaine

    2010-01-01

    In this study I examine the manner in which high-achieving African American undergraduate men negotiate cultural challenges in a predominantly White institution (PWI). Cultural theory underpins the conceptual framework of this case study. Basing the study in cultural theory provided a lens through which to view the lived experiences of the twenty…

  5. Examining the Relationships between Math Achievement and the Resiliency of High School Seniors

    ERIC Educational Resources Information Center

    Chadwick, Mona

    2009-01-01

    The purpose of this research is to explore the relationship between math achievement and student resiliency among high school seniors. Seniors from nine school districts in southeast Texas participated by answering a short demographic survey and the "Healthy Kids Resiliency Assessment" (Constantine & Benard, 2001). A total of 457 surveys were…

  6. An Exploratory Study Contrasting High- and Low-Achieving Students' Percent Word Problem Solving

    ERIC Educational Resources Information Center

    Jitendra, Asha K.; Star, Jon R.

    2012-01-01

    This study evaluated whether schema-based instruction (SBI), a promising method for teaching students to represent and solve mathematical word problems, impacted the learning of percent word problems. Of particular interest was the extent that SBI improved high- and low-achieving students' learning and to a lesser degree on the indirect effect of…

  7. High School Success: An Effective Intervention for Achievement and Dropout Prevention

    ERIC Educational Resources Information Center

    Lowder, Christopher Michael

    2012-01-01

    The purpose of this mixed-design study was to use quantitative and qualitative research to explore the effects of High School Success (a course for at-risk ninth graders) and its effectiveness on student achievement, attendance, and dropout prevention. The research questions address whether there is a significant difference between at-risk ninth…

  8. Obesity, High-Calorie Food Intake, and Academic Achievement Trends among U.S. School Children

    ERIC Educational Resources Information Center

    Li, Jian; O'Connell, Ann A.

    2012-01-01

    The authors investigated children's self-reported high-calorie food intake in Grade 5 and its relationship to trends in obesity status and academic achievement over the first 6 years of school. They used 3-level hierarchical linear models in the large-scale database (the Early Childhood Longitudinal Study--Kindergarten Cohort). Findings indicated…

  9. The Effects of Alcohol Use on Academic Achievement in High School

    ERIC Educational Resources Information Center

    Balsa, Ana I.; Giuliano, Laura M.; French, Michael T.

    2011-01-01

    This paper examines the effects of alcohol use on high school students' quality of learning. We estimate fixed-effects models using data from the National Longitudinal Study of Adolescent Health. Our primary measure of academic achievement is the student's grade point average (GPA) abstracted from official school transcripts. We find that…

  10. Confronting the Universal Disbelief that Poor Children Can Achieve at High Levels

    ERIC Educational Resources Information Center

    Kelleher, Paul

    2006-01-01

    In her first year as superintendent of the Atlanta Public Schools, Beverly Hall encountered what she describes as the nearly universal disbelief that poor children of color can achieve high levels of learning. This chapter recounts how she confronted this and other obstacles and challenges as the new leader of the Atlanta Public Schools. Hall is…

  11. Faculty Perceptions of High-Achieving Male Collegians: A Critical Race Theory Analysis

    ERIC Educational Resources Information Center

    Comeaux, Eddie

    2013-01-01

    Critical race theory was employed as an interpretive framework to explore faculty perceptions of the academic accomplishments of high-achieving Black and White male collegians. Using photo elicitation methodology, faculty participants responded to a randomly assigned photograph of and vignette about either a Black or White male student. While most…

  12. A Study of the Impact of Block Scheduling on Student Academic Achievement in Public High Schools

    ERIC Educational Resources Information Center

    Norton, Mary Kay

    2010-01-01

    The number of public high schools implementing a semester 4 x 4 block scheduling design within the state of South Carolina has tripled since 2005. However, minimal local research has been conducted regarding the impact of block scheduling on student academic achievement. The purpose of this study was to determine if significant differences exist…

  13. Antecedent and Concurrent Psychosocial Skills That Support High Levels of Achievement within Talent Domains

    ERIC Educational Resources Information Center

    Olszewski-Kubilius, Paula; Subotnik, Rena F.; Worrell, Frank C.

    2015-01-01

    Motivation and emotional regulation are important for the sustained focused study and practice required for high levels of achievement and creative productivity in adulthood. Using the talent development model proposed by the authors as a framework, the authors discuss several important psychosocial skills based on the psychological research…

  14. The Relationship between Student Attendance and Academic Achievement in a Selected South Dakota High School

    ERIC Educational Resources Information Center

    Johnke, Jennifer

    2013-01-01

    There is limited research available on the relationship between student attendance and academic achievement in secondary school. This quantitative, non-experimental study, conducted within a South Dakota high school of students in grades 9-12 during the years 2006-2012, examined the relationship between student attendance and academic achievement…

  15. Ugandan Immigrant Students' Perceptions of Barriers to Academic Achievement in American High Schools

    ERIC Educational Resources Information Center

    Ssekannyo, Denis

    2010-01-01

    In a world that is now a global village, enterprising individuals, especially from Third World countries, who make it to greener pastures do not leave their children behind. But with a long list of barriers to academic achievement associated with immigrant and minority students in American high schools, an understanding of the experiences and…

  16. Narrowing the Academic Achievement Gap among High School Latino Students through Parental Involvement

    ERIC Educational Resources Information Center

    Parry, Douglas L.

    2010-01-01

    The low academic achievement among Latino students in many inner city high schools leads to higher failure, dropout, and absenteeism rates, as well as lower standardized test scores and graduation rates. The purpose of this study was to explore whether Latino parental attitudes toward and perceptions, level of, and form of involvement may be…

  17. Being Labeled "Nerd": Factors that Influence the Social Acceptance of High-Achieving Students

    ERIC Educational Resources Information Center

    Rentzsch, Katrin; Schutz, Astrid; Schroder-Abe, Michela

    2011-01-01

    The present investigation addresses the question of whether certain factors can protect high-achieving students at risk for being labeled a nerd against devaluation. In 2 studies, 125 and 317 students from Grade 8 evaluated vignettes describing average students and students who were called "nerds." Results indicate that being modest about good…

  18. Students' High School Organizational Leadership Opportunities and Their Influences on Academic Achievement and Civic Participation

    ERIC Educational Resources Information Center

    Elemen, Jennifer E.

    2015-01-01

    The purpose of this quantitative study was to analyze high school leadership praxis for its inclusion of students in organizational leadership dialogue and decision-making and the influences of these factors on student achievement and civic participation. Survey questionnaire data were provided by 215 full-time enrolled undergraduate students from…

  19. High-Stakes Testing and Student Achievement: Does Accountability Pressure Increase Student Learning?

    ERIC Educational Resources Information Center

    Nichols, Sharon L.; Glass, Gene V.; Berliner, David C.

    2006-01-01

    This study examined the relationship between high-stakes testing pressure and student achievement across 25 states. Standardized portfolios were created for each study state. Each portfolio contained a range of documents that told the "story" of accountability implementation and impact in that state. Using the "law of comparative judgments," over…

  20. Further Evidence of an Engagement-Achievement Paradox among U.S. High School Students

    ERIC Educational Resources Information Center

    Shernoff, David J.; Schmidt, Jennifer A.

    2008-01-01

    Achievement, engagement, and students' quality of experience were compared by racial and ethnic group in a sample of students (N = 586) drawn from 13 high schools with diverse ethnic and socioeconomic student populations. Using the Experience Sampling Method (ESM), 3,529 samples of classroom experiences were analyzed along with self-reported…

  1. Ego Identity, Cognitive Ability, and Academic Achievement: Variances, Relationships, and Gender Differences Among High School Sophomores.

    ERIC Educational Resources Information Center

    Wrabel, Thomas J.

    This study examined the contributions of cognitive quantitative ability, cognitive verbal ability, normed test achievement and grade point average to the ego identity of 202 high school sophomores. The instrumentation used in this study was as follows: (1) Rasmussen Ego Identity Scale: Revised Short Form; (2) The 3-R's Abilities and Achievement…

  2. Integrating Economic and Social Policy: Good Practices from High-Achieving Countries. Innocenti Working Papers.

    ERIC Educational Resources Information Center

    Mehrotra, Santosh

    This paper examines the successes of 10 "high achievers," countries with social indicators far higher than might be expected, given their national wealth, pulling together the lessons learned for social policy in the developing world. The 10 countries identified are Costa Rica, Cuba, Barbados, Botswana, Zimbabwe, Mauritius, Kerala, Sri Lanka,…

  3. The Relationship between Student Achievement and Charter High Schools in Washington, DC

    ERIC Educational Resources Information Center

    Pardo, Alexandra

    2013-01-01

    This study was designed to determine if differences in student achievement existed between traditional public and charter high schools in the District of Columbia. The study examined student outcomes on the standardized state test in reading and math from 2006 to 2010 utilizing descriptive statistics, crosstab analysis, chi-square tests…

  4. Experiencing More Mathematics Anxiety than Expected? Contrasting Trait and State Anxiety in High Achieving Students

    ERIC Educational Resources Information Center

    Roos, A.-L.; Bieg, M.; Goetz, T.; Frenzel, A. C.; Taxer, J.; Zeidner, M.

    2015-01-01

    This study examined mathematics anxiety among high and low achieving students (N = 237, grades 9 and 10) by contrasting trait (habitual) and state (momentary) assessments of anxiety. Previous studies have found that trait anxiety measures are typically rated higher than state measures. Furthermore, the academic self-concept has been identified to…

  5. Actively Closing the Gap? Social Class, Organized Activities, and Academic Achievement in High School

    ERIC Educational Resources Information Center

    Morris, David S.

    2015-01-01

    Participation in Organized Activities (OA) is associated with positive behavioral and developmental outcomes in children. However, less is known about how particular aspects of participation affect the academic achievement of high school students from different social class positions. Using the Education Longitudinal Study of 2002, this study…

  6. The College-Choice Process of High Achieving Freshmen: A Comparative Case Study

    ERIC Educational Resources Information Center

    Dale, Amanda

    2010-01-01

    The purpose of this study was to examine the college-choice process of high achieving students. Employing current literature and previous research, it combined current models of college choice and the influential factors identified throughout the literature while utilizing the concept of bounded rationality to create a conceptual framework to…

  7. Communication Satisfaction, Organizational Citizenship Behavior and the Relationship to Student Achievement in High Schools

    ERIC Educational Resources Information Center

    Blanchard, Gayle A.

    2012-01-01

    This study used a correlational design that allowed the researcher to examine the relationship among communication satisfaction, organizational citizenship behaviors (OCB) and student achievement. High school teachers were surveyed from a convenience sample of 12 school districts in Arizona. Established instruments were used to survey…

  8. One-to-One Computing and Student Achievement in Ohio High Schools

    ERIC Educational Resources Information Center

    Williams, Nancy L.; Larwin, Karen H.

    2016-01-01

    This study explores the impact of one-to-one computing on student achievement in Ohio high schools as measured by performance on the Ohio Graduation Test (OGT). The sample included 24 treatment schools that were individually paired with a similar control school. An interrupted time series methodology was deployed to examine OGT data over a period…

  9. Turkish High School Students' Biology Achievement in Relation to Academic Self-Regulation

    ERIC Educational Resources Information Center

    Yumusak, Necmettin; Sungur, Semra; Cakiroglu, Jale

    2007-01-01

    This study aimed at investigating the contribution of motivational beliefs, cognitive, and metacognitive strategy use to Turkish high school students' achievement in biology. In order to investigate the specified purpose of the study, 519 tenth-grade students were administered the Motivated Strategies for Learning Questionnaire (Pintrich, Smith,…

  10. Moving beyond Time and Choice: Challenge, Motivation and Achievement during Independent Reading in High School

    ERIC Educational Resources Information Center

    Perks, Kevin

    2010-01-01

    In response to concerns about poor engagement and achievement in reading, some high schools have implemented independent reading programs to give students time to read self-selected texts during school. Some schools are also adopting the Lexile framework as a tool for matching readers with challenging texts in order to improve reading motivation…

  11. The Impact of Reading Success Academy on High School Reading Achievement

    ERIC Educational Resources Information Center

    Burlison, Kelly; Chave, Josh

    2014-01-01

    The study explores the effectiveness of the Reading Success Academy on the reading achievement of the selected group of ninth-grade students in a comprehensive high school. We examine in what ways the Reading Success Academy may improve the reading proficiency rates and amount of reading growth of ninth-grade students. The results indicate that…

  12. Effect of Textbook Readability on Student Achievement in High School Chemistry.

    ERIC Educational Resources Information Center

    Rapp, D. Neil

    2001-01-01

    Notes the readability level of many high school chemistry textbooks is far above students' reading levels. Conducts two separate studies, making every effort to keep the two classes as similar as possible in all aspects except text. Finds strong evidence that changing the chemistry textbook resulted in an increase in student achievement. Suggests…

  13. Organizational Practices of High-Achieving Rural School Districts in California's San Joaquin Valley

    ERIC Educational Resources Information Center

    Doerksen, Amanda López; Wise, Donald

    2016-01-01

    For over 25 years, researchers have identified "best practices" used by high-achieving school districts. However, little research exists regarding rural school systems, making it difficult to determine whether the best practices identified are relevant within this context. This study filled a void in research by focusing on the…

  14. Cognitive Abilities and Motivational Processes in High School Students' Situational Engagement and Achievement in Science.

    ERIC Educational Resources Information Center

    Lau, Shun; Roeser, Robert W.

    2002-01-01

    Building on R. Snow's two pathways to achievement outcomes (1989), examined how cognitive and motivational factors associated with the performance and commitment pathways respectively contributed to prediction of outcomes in science for 491 high school students. Results are consistent with Snow's conjecture that factors related to both pathways…

  15. Balancing Dreams and Realities: The College Choice Process for High-Achieving Latinas

    ERIC Educational Resources Information Center

    Hernández, Ebelia

    2015-01-01

    This study's narratives of 17 high-achieving Latinas revealed how their college choice was a constant balancing of individual and family expectations, being "close, but far enough away," and "getting your money's worth." With the use of critical race theory, further analysis revealed the influence of "familismo" on…

  16. Measuring the Outliers: An Introduction to Out-of-Level Testing with High-Achieving Students

    ERIC Educational Resources Information Center

    Rambo-Hernandez, Karen E.; Warne, Russell T.

    2015-01-01

    Out-of-level testing is an underused strategy for addressing the needs of students who score in the extremes, and when used wisely, it could provide educators with a much more accurate picture of what students know. Out-of-level testing has been shown to be an effective assessment strategy with high-achieving students; however, out-of-level…

  17. The Relationship between Illinois School District Superintendent Longevity and High School Student Achievement

    ERIC Educational Resources Information Center

    Libka, Robert J.

    2012-01-01

    Frequent changes in school district superintendents may be having a detrimental impact on student achievement. Rapid changes in leadership today parallel the present (NCLB) era of high stakes state assessments. The goal of the study was to provide correlation research that would have a positive effect on school district management, superintendent…

  18. Teachers and Student Achievement in the Chicago Public High Schools. WP 2002-28. Revised

    ERIC Educational Resources Information Center

    Aaronson, Daniel; Barrow, Lisa; Sander, William

    2003-01-01

    Using unique administrative data on Chicago public high school students and their teachers, we are able to estimate the importance of teachers on student mathematical achievement. We find that teachers are educationally and statistically important. To be sure, sampling variation and other measurement issues can strongly influence estimates of…

  19. School Board-Superintendent Relations in Support of High Student Achievement. The Informed Educator Series.

    ERIC Educational Resources Information Center

    Porch, Stephanie; Protheroe, Nancy

    The context of school district governance is changing and becoming more complex. The individual roles of school board members and superintendents, and the relationship between school board members and superintendents are becoming increasingly important in light of the recent mandates for high student achievement. This brief looks at issues…

  20. The Transition Experiences of High-Achieving, Low-Income Undergraduates in an Elite College Environment

    ERIC Educational Resources Information Center

    McLoughlin, Paul J., II

    2012-01-01

    This hermeneutic phenomenological study describes the lived experiences of high-achieving, low-income undergraduates and their transition into a college environment historically reserved for wealthy students. The results of this study indicate that these students are flourishing in full need-based financial aid programs as a result of their own…

  1. What Attracts High-Achieving Socioeconomically Disadvantaged Students to the Physical Sciences and Engineering?

    ERIC Educational Resources Information Center

    Conrad, Sarah; Canetto, Silvia Sara; MacPhee, David; Farro, Samantha

    2009-01-01

    Socioeconomically disadvantaged (SED) students are less likely to major in physical sciences or engineering. To guide recruitment and retention of a diversity of talent, this study examined what attracts high-achieving SED students to these fields. Participants were 50 undergraduates majoring in physical sciences or engineering enrolled in the…

  2. Raising Reading Achievement in Middle and High Schools: Five Simple-to-Follow Strategies. Second Edition

    ERIC Educational Resources Information Center

    McEwan, Elaine K.

    2006-01-01

    In response to the No Child Left Behind Act (NCLB), raising literacy levels in secondary schools has taken on a new urgency. Recognized literacy author, Elaine K. McEwan, focuses her revised second edition on enhancing the "five big ideas" for raising reading achievement with seven cognitive strategies of highly effective readers and more than…

  3. School Factors Related to Reading Achievement in Rural Schools with and without High Poverty

    ERIC Educational Resources Information Center

    Miller, Seth W.

    2013-01-01

    This quantitative study identified how rural schools differ on five school-level factors related to student achievement according to their performance on Grade 3 reading. Through use of a MANOVA test, it was shown that principals of high-poverty rural schools that made AYP in Grade 3 reading reported significantly higher levels of guaranteed and…

  4. Brain Structure and Resting-State Functional Connectivity in University Professors with High Academic Achievement

    ERIC Educational Resources Information Center

    Li, Weiwei; Yang, Wenjing; Li, Wenfu; Li, Yadan; Wei, Dongtao; Li, Huimin; Qiu, Jiang; Zhang, Qinglin

    2015-01-01

    Creative persons play an important role in technical innovation and social progress. There is little research on the neural correlates with researchers with high academic achievement. We used a combined structural (regional gray matter volume, rGMV) and functional (resting-state functional connectivity analysis, rsFC) approach to examine the…

  5. Consequences of the Confucian Culture: High Achievement but Negative Psychological Attributes?

    ERIC Educational Resources Information Center

    Ho, Irene T.; Hau, Kit-Tai

    2010-01-01

    In "Unforgiving Confucian culture: A breeding ground for high academic achievement, test anxiety and self-doubt?" Stankov (in press) provides three reasons for caution against over-glorifying the academic excellence of Confucian Asian learners, namely that it may lead to a reluctance to change their rote learning approach which is not conducive to…

  6. Academic Identity Status, Goal Orientation, and Academic Achievement among High School Students

    ERIC Educational Resources Information Center

    Hejazi, Elaheh; Lavasani, Masoud Gholamali; Amani, Habib; Was, Christopher A.

    2012-01-01

    The aim of the present study was to determine the relationship between academic identity status, goal orientations and academic achievement. 301 first year high school students completed the Academic Identity Measure and Goal Orientation Questionnaire. The average of 10 exam scores in the final semester was used as an index of academic…

  7. GIOVE: a new detector setup for high sensitivity germanium spectroscopy at shallow depth

    NASA Astrophysics Data System (ADS)

    Heusser, G.; Weber, M.; Hakenmüller, J.; Laubenstein, M.; Lindner, M.; Maneschg, W.; Simgen, H.; Stolzenburg, D.; Strecker, H.

    2015-11-01

    We report on the development and construction of the high-purity germanium spectrometer setup GIOVE (Germanium Inner Outer VEto), recently built and now operated at the shallow underground laboratory of the Max-Planck-Institut für Kernphysik, Heidelberg. Particular attention was paid to the design of a novel passive and active shield, aiming at efficient rejection of environmental and muon induced radiation backgrounds. The achieved sensitivity level of ≤ 100 \\upmu Bq kg^{-1} for primordial radionuclides from U and Th in typical γ ray sample screening measurements is unique among instruments located at comparably shallow depths and can compete with instruments at far deeper underground sites.

  8. Magnetic probe array with high sensitivity for fluctuating field.

    PubMed

    Kanamaru, Yuki; Gota, Hiroshi; Fujimoto, Kayoko; Ikeyama, Taeko; Asai, Tomohiko; Takahashi, Tsutomu; Nogi, Yasuyuki

    2007-03-01

    A magnetic probe array is constructed to measure precisely the spatial structure of a small fluctuating field included in a strong confinement field that varies with time. To exclude the effect of the confinement field, the magnetic probes consisting of figure-eight-wound coils are prepared. The spatial structure of the fluctuating field is obtained from a Fourier analysis of the probe signal. It is found that the probe array is more sensitive to the fluctuating field with a high mode number than that with a low mode number. An experimental demonstration of the present method is attempted using a field-reversed configuration plasma, where the fluctuating field with 0.1% of the confinement field is successfully detected.

  9. Radiation noise in a high sensitivity star sensor

    NASA Technical Reports Server (NTRS)

    Parkinson, J. B.; Gordon, E.

    1972-01-01

    An extremely accurate attitude determination was developed for space applications. This system uses a high sensitivity star sensor in which the photomultiplier tube is subject to noise generated by space radiations. The space radiation induced noise arises from trapped electrons, solar protons and other ionizing radiations, as well as from dim star background. The solar activity and hence the electron and proton environments are predicted through the end of the twentieth century. The available data for the response of the phototube to proton, electron, gamma ray, and bremsstrahlung radiations are reviewed and new experimental data is presented. A simulation was developed which represents the characteristics of the effect of radiations on the star sensor, including the non-stationarity of the backgrounds.

  10. Versatile, high-sensitivity faraday cup array for ion implanters

    DOEpatents

    Musket, Ronald G.; Patterson, Robert G.

    2003-01-01

    An improved Faraday cup array for determining the dose of ions delivered to a substrate during ion implantation and for monitoring the uniformity of the dose delivered to the substrate. The improved Faraday cup array incorporates a variable size ion beam aperture by changing only an insertable plate that defines the aperture without changing the position of the Faraday cups which are positioned for the operation of the largest ion beam aperture. The design enables the dose sensitivity range, typically 10.sup.11 -10.sup.18 ions/cm.sup.2 to be extended to below 10.sup.6 ions/cm.sup.2. The insertable plate/aperture arrangement is structurally simple and enables scaling to aperture areas between <1 cm.sup.2 and >750 cm.sup.2, and enables ultra-high vacuum (UHV) applications by incorporation of UHV-compatible materials.

  11. Course Syllabi: High Expectations...High Achievement. Social Studies (and) History.

    ERIC Educational Resources Information Center

    Murray State Univ., KY.

    The document describes social studies and history courses offered in the junior high and senior high schools of Henry County, Tennessee. The syllabi were developed as part of a Teacher's Corps Demonstration Project. The overall objectives of the syllabi are to inform students and parents of the minimum competencies expected in social studies and…

  12. High Expectations--High Achievement on Literacy: "What Shall We Do in This Hangman's Hour?"

    ERIC Educational Resources Information Center

    Linnakyla, Pirjo

    Finland is a country of great expectations on literacy and literacy education. High expectations and demands have, however, a darker side. High expectations of society, parents, and teachers may have an effect on the students' self-esteem. The economic recession in the early 1990s strongly accelerated the change in literacy demands and…

  13. The Information Search Process of High, Middle, and Low Achieving High School Seniors.

    ERIC Educational Resources Information Center

    Kuhlthau, Carol C.

    Traditionally, library instruction has been based on the sources in the library and not on the process of seeking information. A new approach to library skills may be needed to enable students to become effective information users. This study investigated the information search process of 140 high school seniors in six high schools. Subjects were…

  14. Cultivating a Growth Mindset in Students at a High-Achieving High School

    ERIC Educational Resources Information Center

    Fegley, Alan D.

    2010-01-01

    The purpose of this EPP is to develop a plan for changing the mindset of a large number of Haddonfield Memorial High School (HMHS) students from a fixed mindset to a growth mindset. HMHS is by most conventional measures a high performing school. Typically 100% of the students graduate with 96% of the students attending two or four year colleges…

  15. No More 1s: High Expectations Can Lead to High Achievement

    ERIC Educational Resources Information Center

    Cervone, Laureen; DiMartino, Lisa; Kerr, Kris

    2010-01-01

    The school district in Middletown, New York, in the state's Orange County, today serves close to 7,000 students in four elementary schools, two middle schools, and one high school. The district is classified by the state in the highest of three Need-to-Resource-Capacity groups, an urban or suburban school district with high student needs in…

  16. In-line microfluidic integration of photonic crystal fibres as a highly sensitive refractometer.

    PubMed

    Wu, Chuang; Tse, Ming-Leung Vincent; Liu, Zhengyong; Guan, Bai-Ou; Zhang, A Ping; Lu, Chao; Tam, Hwa-Yaw

    2014-11-01

    Photonic crystal fibres appear to be an ideal platform for the realisation of novel optofluidic devices and sensors due to their waveguide nature and microstructured architecture. In this paper, we present the fabrication and characterisation of an in-line photonic crystal fibre microfluidic refractometer enabled by a C-shaped fibre. The C-shaped fibre spliced in-between the photonic crystal fibre and the single-mode fibre allows simultaneous in-line optical signal delivery and analyte fluid feeding. Through an arc discharge pre-treatment technique, we successfully achieve selective exploitation of only the central two channels of the photonic crystal fibre for microfluidic sensing. After constructing a Sagnac interferometer, a highly sensitive refractometer with a sensitivity of 8699 nm per RIU was achieved experimentally; this agrees very well with the theoretical value of 8675 nm per RIU. As a demonstration for label-free optical sensing application, the refractometer was used to measure the concentration of NaCl solution with a sensitivity of 15.08 nm/(1 wt%) and a detection limit of 2.3 × 10(-3) wt% (23 ppm). PMID:25142213

  17. Efficient dye regeneration at low driving force achieved in triphenylamine dye LEG4 and TEMPO redox mediator based dye-sensitized solar cells.

    PubMed

    Yang, Wenxing; Vlachopoulos, Nick; Hao, Yan; Hagfeldt, Anders; Boschloo, Gerrit

    2015-06-28

    Minimizing the driving force required for the regeneration of oxidized dyes using redox mediators in an electrolyte is essential to further improve the open-circuit voltage and efficiency of dye-sensitized solar cells (DSSCs). Appropriate combinations of redox mediators and dye molecules should be explored to achieve this goal. Herein, we present a triphenylamine dye, LEG4, in combination with a TEMPO-based electrolyte in acetonitrile (E(0) = 0.89 V vs. NHE), reaching an efficiency of up to 5.4% under one sun illumination and 40% performance improvement compared to the previously and widely used indoline dye D149. The origin of this improvement was found to be the increased dye regeneration efficiency of LEG4 using the TEMPO redox mediator, which regenerated more than 80% of the oxidized dye with a driving force of only ∼0.2 eV. Detailed mechanistic studies further revealed that in addition to electron recombination to oxidized dyes, recombination of electrons from the conducting substrate and the mesoporous TiO2 film to the TEMPO(+) redox species in the electrolyte accounts for the reduced short circuit current, compared to the state-of-the-art cobalt tris(bipyridine) electrolyte system. The diffusion length of the TEMPO-electrolyte based DSSCs was determined to be ∼0.5 μm, which is smaller than the ∼2.8 μm found for cobalt-electrolyte based DSSCs. These results show the advantages of using LEG4 as a sensitizer, compared to previously record indoline dyes, in combination with a TEMPO-based electrolyte. The low driving force for efficient dye regeneration presented by these results shows the potential to further improve the power conversion efficiency (PCE) of DSSCs by utilizing redox couples and dyes with a minimal need of driving force for high regeneration yields.

  18. Efficient dye regeneration at low driving force achieved in triphenylamine dye LEG4 and TEMPO redox mediator based dye-sensitized solar cells.

    PubMed

    Yang, Wenxing; Vlachopoulos, Nick; Hao, Yan; Hagfeldt, Anders; Boschloo, Gerrit

    2015-06-28

    Minimizing the driving force required for the regeneration of oxidized dyes using redox mediators in an electrolyte is essential to further improve the open-circuit voltage and efficiency of dye-sensitized solar cells (DSSCs). Appropriate combinations of redox mediators and dye molecules should be explored to achieve this goal. Herein, we present a triphenylamine dye, LEG4, in combination with a TEMPO-based electrolyte in acetonitrile (E(0) = 0.89 V vs. NHE), reaching an efficiency of up to 5.4% under one sun illumination and 40% performance improvement compared to the previously and widely used indoline dye D149. The origin of this improvement was found to be the increased dye regeneration efficiency of LEG4 using the TEMPO redox mediator, which regenerated more than 80% of the oxidized dye with a driving force of only ∼0.2 eV. Detailed mechanistic studies further revealed that in addition to electron recombination to oxidized dyes, recombination of electrons from the conducting substrate and the mesoporous TiO2 film to the TEMPO(+) redox species in the electrolyte accounts for the reduced short circuit current, compared to the state-of-the-art cobalt tris(bipyridine) electrolyte system. The diffusion length of the TEMPO-electrolyte based DSSCs was determined to be ∼0.5 μm, which is smaller than the ∼2.8 μm found for cobalt-electrolyte based DSSCs. These results show the advantages of using LEG4 as a sensitizer, compared to previously record indoline dyes, in combination with a TEMPO-based electrolyte. The low driving force for efficient dye regeneration presented by these results shows the potential to further improve the power conversion efficiency (PCE) of DSSCs by utilizing redox couples and dyes with a minimal need of driving force for high regeneration yields. PMID:26016854

  19. Graphene enhanced evanescent field in microfiber multimode interferometer for highly sensitive gas sensing.

    PubMed

    Yao, B C; Wu, Y; Zhang, A Q; Rao, Y J; Wang, Z G; Cheng, Y; Gong, Y; Zhang, W L; Chen, Y F; Chiang, K S

    2014-11-17

    Graphene based new physics phenomena are leading to a variety of stimulating graphene-based photonic devices. In this study, the enhancement of surface evanescent field by graphene cylindrical cladding is observed, for the first time, by using a graphene-coated microfiber multi-mode interferometer (GMMI). It is found theoretically and experimentally that the light transmitting in the fiber core is efficiently dragged by the graphene, hence significantly enhancing the evanescent fields, and subsequently improving the sensitivity of the hybrid waveguide. The experimental results for gas sensing verified the theoretical prediction, and ultra-high sensitivities of ~0.1 ppm for NH(3) gas detection and ~0.2 ppm for H(2)O vapor detection are achieved, which could be used for trace analysis. The enhancement of surface evanescent field induced by graphene may pave a new way for developing novel graphene-based all-fiber devices with compactness, low cost, and temperature immunity.

  20. Fluorescent Protein Nanowire-Mediated Protein Microarrays for Multiplexed and Highly Sensitive Pathogen Detection.

    PubMed

    Men, Dong; Zhou, Juan; Li, Wei; Leng, Yan; Chen, Xinwen; Tao, Shengce; Zhang, Xian-En

    2016-07-13

    Protein microarrays are powerful tools for high-throughput and simultaneous detection of different target molecules in complex biological samples. However, the sensitivity of conventional fluorescence-labeling protein detection methods is limited by the availability of signal molecules for binding to the target molecule. Here, we built a multifunctional fluorescent protein nanowire (FNw) by harnessing self-assembly of yeast amyloid protein. The FNw integrated a large number of fluorescent molecules, thereby enhancing the fluorescent signal output in target detection. The FNw was then combined with protein microarray technology to detect proteins derived from two pathogens, including influenza virus (hemagglutinin 1, HA1) and human immunodeficiency virus (p24 and gp120). The resulting detection sensitivity achieved a 100-fold improvement over a commercially available detection reagent. PMID:27315221

  1. Achieving highly dispersed nanofibres at high loading in carbon nanofibre-metal composites

    NASA Astrophysics Data System (ADS)

    Kang, Jianli; Nash, Philip; Li, Jiajun; Shi, Chunsheng; Zhao, Naiqin

    2009-06-01

    In order to tap into the advantages of the properties of carbon nanotubes (CNTs) or carbon nanofibres (CNFs) in composites, the high dispersion of CNTs (or CNFs) and strong interfacial bonding are the key issues which are still challenging. In the current work, a novel approach, consisting of in situ synthesis of CNFs within the Cu powders and mixing Cu ions with the in situ CNF(Ni/Y)-Cu composite powders in a solvent, was developed to highly disperse CNFs in a Cu matrix. The composite, produced by vacuum hot pressing, shows extremely high strength, 3.6 times more than that of the matrix material alone. It is worth mentioning that this method can disperse CNFs at high loading in a metal matrix, inferring good potential for applications, such as electronic packaging materials.

  2. Modeling stability of growth between mathematics and science achievement during middle and high school.

    PubMed

    Ma, Xin; Ma, Lingling

    2004-04-01

    In this study, the authors introduced a multivariate multilevel model to estimate the consistency among students and schools in the rates of growth between mathematics and science achievement during the entire middle and high school years with data from the Longitudinal Study of American Youth (LSAY). There was no evident consistency in the rates of growth between mathematics and science achievement among students, and this inconsistency was not much influenced by student characteristics and school characteristics. However, there was evident consistency in the average rates of growth between mathematics and science achievement among schools, and this consistency was influenced by student characteristics and school characteristics. Major school-level variables associated with parental involvement did not show any significant impacts on consistency among either students or schools. Results call for educational policies that promote collaboration between mathematics and science departments or teachers.

  3. Relationship of constructivist learning environment to student attitudes and achievement in high school mathematics and science

    NASA Astrophysics Data System (ADS)

    Dethlefs, Theresa Marie

    This study investigated the relationship of constructivist learning environment and standards-based teaching practices to student achievement and attitudes (self-efficacy, intrinsic value, and learning strategies) in Algebra and Biology. Further, these relationships were examined as a function of student gender and prior achievement. A purposive sample of 804 high school students enrolled in Biology I, Algebra I, or Advanced Algebra was selected for inclusion in this study. Although the dimensions of constructivist learning environment that contributed to predicting student achievement and attitudes varied by content area and criterion, the results of the present study generally provide strong support for a positive relationship between constructivist learning environment and student attitudes, but little support for a direct relationship to student achievement. Teacher reports of overall constructivist learning environment were not correlated with achievement or attitudes. Observer reports of constructivist learning environment were correlated with student intrinsic value and learning strategies. Student reports of constructivist learning environment were correlated with all three attitude measures. Multiple regression findings showed that neither overall constructivist learning environment nor standards-based teaching practices predicted achievement in any of the content areas. Overall constructivist learning environment and standards-based teaching practices were significant positive predictors of student intrinsic value and learning strategies in all three content areas, after controlling for student and classroom demographic variables. Overall constructivist learning environment and standards-based teaching practices were also significant positive predictors of self-efficacy in Algebra 1. In addition, standards-based teaching practices was a significant positive predictor of student self-efficacy in Biology. No specific dimensions of constructivist learning

  4. Iridium Oxide Nanotube Electrodes for Highly Sensitive and Prolonged Intracellular Measurement of Action Potentials

    PubMed Central

    Lin, Ziliang Carter; Xie, Chong; Osakada, Yasuko; Cui, Yi; Cui, Bianxiao

    2014-01-01

    Intracellular recording of action potentials is important to understand electrically-excitable cells. Recently, vertical nanoelectrodes have been developed to achieve highly sensitive, minimally invasive, and large scale intracellular recording. It has been demonstrated that the vertical geometry is crucial for the enhanced signal detection. Here we develop nanoelectrodes made up of nanotubes of iridium oxide. When cardiomyocytes are cultured upon those nanotubes, the cell membrane not only wraps around the vertical tubes but also protrudes deep into the hollow center. We show that this geometry enhances cell-electrode coupling and results in measuring much larger intracellular action potentials. The nanotube electrodes afford much longer intracellular access and are minimally invasive, making it possible to achieve stable recording up to an hour in a single session and more than 8 days of consecutive daily recording. This study suggests that the electrode performance can be significantly improved by optimizing the electrode geometry. PMID:24487777

  5. The role of chronotype, gender, test anxiety, and conscientiousness in academic achievement of high school students.

    PubMed

    Rahafar, Arash; Maghsudloo, Mahdis; Farhangnia, Sajedeh; Vollmer, Christian; Randler, Christoph

    2016-01-01

    Previous findings have demonstrated that chronotype (morningness/intermediate/eveningness) is correlated with cognitive functions, that is, people show higher mental performance when they do a test at their preferred time of day. Empirical studies found a relationship between morningness and higher learning achievement at school and university. However, only a few of them controlled for other moderating and mediating variables. In this study, we included chronotype, gender, conscientiousness and test anxiety in a structural equation model (SEM) with grade point average (GPA) as academic achievement outcome. Participants were 158 high school students and results revealed that boys and girls differed in GPA and test anxiety significantly, with girls reporting better grades and higher test anxiety. Moreover, there was a positive correlation between conscientiousness and GPA (r = 0.17) and morningness (r = 0.29), respectively, and a negative correlation between conscientiousness and test anxiety (r = -0.22). The SEM demonstrated that gender was the strongest predictor of academic achievement. Lower test anxiety predicted higher GPA in girls but not in boys. Additionally, chronotype as moderator revealed a significant association between gender and GPA for evening types and intermediate types, while intermediate types showed a significant relationship between test anxiety and GPA. Our results suggest that gender is an essential predictor of academic achievement even stronger than low or absent test anxiety. Future studies are needed to explore how gender and chronotype act together in a longitudinal panel design and how chronotype is mediated by conscientiousness in the prediction of academic achievement.

  6. High fat diet promotes achievement of peak bone mass in young rats

    SciTech Connect

    Malvi, Parmanand; Piprode, Vikrant; Chaube, Balkrishna; Pote, Satish T.; Mittal, Monika; Chattopadhyay, Naibedya; Wani, Mohan R.; Bhat, Manoj Kumar

    2014-12-05

    Highlights: • High fat diet helps in achieving peak bone mass at younger age. • Shifting from high fat to normal diet normalizes obese parameters. • Bone parameters are sustained even after withdrawal of high fat diet. - Abstract: The relationship between obesity and bone is complex. Epidemiological studies demonstrate positive as well as negative correlation between obesity and bone health. In the present study, we investigated the impact of high fat diet-induced obesity on peak bone mass. After 9 months of feeding young rats with high fat diet, we observed obesity phenotype in rats with increased body weight, fat mass, serum triglycerides and cholesterol. There were significant increases in serum total alkaline phosphatase, bone mineral density and bone mineral content. By micro-computed tomography (μ-CT), we observed a trend of better trabecular bones with respect to their microarchitecture and geometry. This indicated that high fat diet helps in achieving peak bone mass and microstructure at younger age. We subsequently shifted rats from high fat diet to normal diet for 6 months and evaluated bone/obesity parameters. It was observed that after shifting rats from high fat diet to normal diet, fat mass, serum triglycerides and cholesterol were significantly decreased. Interestingly, the gain in bone mineral density, bone mineral content and trabecular bone parameters by HFD was retained even after body weight and obesity were normalized. These results suggest that fat rich diet during growth could accelerate achievement of peak bone mass that is sustainable even after withdrawal of high fat diet.

  7. Achievement Motivation of the High School Students: A Case Study among Different Communities of Goalpara District of Assam

    ERIC Educational Resources Information Center

    Sarangi, C.

    2015-01-01

    Achievement motivation is a consistent striving force of an individual to achieve success to a certain standard of excellence in competing situation. In this study an attempt was made to study the effect of achievement motivation on the academic achievement of the high school students of tribal and non tribal communities in relation to their sex…

  8. Graphene nanomesh as highly sensitive chemiresistor gas sensor.

    PubMed

    Paul, Rajat Kanti; Badhulika, Sushmee; Saucedo, Nuvia M; Mulchandani, Ashok

    2012-10-01

    Graphene is a one atom thick carbon allotrope with all surface atoms that has attracted significant attention as a promising material as the conduction channel of a field-effect transistor and chemical field-effect transistor sensors. However, the zero bandgap of semimetal graphene still limits its application for these devices. In this work, ethanol-chemical vapor deposition (CVD) of a grown p-type semiconducting large-area monolayer graphene film was patterned into a nanomesh by the combination of nanosphere lithography and reactive ion etching and evaluated as a field-effect transistor and chemiresistor gas sensors. The resulting neck-width of the synthesized nanomesh was about ∼20 nm and was comprised of the gap between polystyrene (PS) spheres that was formed during the reactive ion etching (RIE) process. The neck-width and the periodicities of the graphene nanomesh (GNM) could be easily controlled depending on the duration/power of the RIE and the size of the PS nanospheres. The fabricated GNM transistor device exhibited promising electronic properties featuring a high drive current and an I(ON)/I(OFF) ratio of about 6, significantly higher than its film counterpart. Similarly, when applied as a chemiresistor gas sensor at room temperature, the graphene nanomesh sensor showed excellent sensitivity toward NO(2) and NH(3), significantly higher than their film counterparts. The ethanol-based graphene nanomesh sensors exhibited sensitivities of about 4.32%/ppm in NO(2) and 0.71%/ppm in NH(3) with limits of detection of 15 and 160 ppb, respectively. Our demonstrated studies on controlling the neck width of the nanomesh would lead to further improvement of graphene-based transistors and sensors.

  9. Graphene nanomesh as highly sensitive chemiresistor gas sensor.

    PubMed

    Paul, Rajat Kanti; Badhulika, Sushmee; Saucedo, Nuvia M; Mulchandani, Ashok

    2012-10-01

    Graphene is a one atom thick carbon allotrope with all surface atoms that has attracted significant attention as a promising material as the conduction channel of a field-effect transistor and chemical field-effect transistor sensors. However, the zero bandgap of semimetal graphene still limits its application for these devices. In this work, ethanol-chemical vapor deposition (CVD) of a grown p-type semiconducting large-area monolayer graphene film was patterned into a nanomesh by the combination of nanosphere lithography and reactive ion etching and evaluated as a field-effect transistor and chemiresistor gas sensors. The resulting neck-width of the synthesized nanomesh was about ∼20 nm and was comprised of the gap between polystyrene (PS) spheres that was formed during the reactive ion etching (RIE) process. The neck-width and the periodicities of the graphene nanomesh (GNM) could be easily controlled depending on the duration/power of the RIE and the size of the PS nanospheres. The fabricated GNM transistor device exhibited promising electronic properties featuring a high drive current and an I(ON)/I(OFF) ratio of about 6, significantly higher than its film counterpart. Similarly, when applied as a chemiresistor gas sensor at room temperature, the graphene nanomesh sensor showed excellent sensitivity toward NO(2) and NH(3), significantly higher than their film counterparts. The ethanol-based graphene nanomesh sensors exhibited sensitivities of about 4.32%/ppm in NO(2) and 0.71%/ppm in NH(3) with limits of detection of 15 and 160 ppb, respectively. Our demonstrated studies on controlling the neck width of the nanomesh would lead to further improvement of graphene-based transistors and sensors. PMID:22931286

  10. Innovative nanostructures for highly sensitive vibrational biosensing (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Popp, Juergen; Mayerhöfer, Thomas; Cialla-May, Dana; Weber, Karina; Huebner, Uwe

    2016-03-01

    Employing vibrational spectroscopy (IR-absorption and Raman spectroscopy) allows for the labelfree detection of molecular specific fingerprints of inorganic, organic and biological substances. The sensitivity of vibrational spectroscopy can be improved by several orders of magnitude via the application of plasmonic active surfaces. Within this contribution we will discuss two such approaches, namely surface enhanced Raman spectroscopy (SERS) as well as surface enhanced IR absorption (SEIRA). It will be shown that SERS using metal colloids as SERS active substrate in combination with a microfluidic lab-on-a-chip (LOC) device enables high throughput and reproducible measurements with highest sensitivity and specificity. The application of such a LOC-SERS approach for therapeutic drug monitoring (e.g. quantitative detection of antibiotics in a urine matrix) will be presented. Furthermore, we will introduce innovative bottom-up strategies to prepare SERS-active nanostructures coated with a lipophilic sensor layer as one-time use SERS substrates for specific food analysis (e.g. quantitative detection of toxic food colorants). The second part of this contribution presents a slit array metamaterial perfect absorber for IR sensing applications consisting of a dielectric layer sandwiched between two metallic layers of which the upper layer is perforated with a periodic array of slits. Light-matter interaction is greatly amplified in the slits, where also the analyte is concentrated, as the surface of the substrate is covered by a thin silica layer. Thus, already small concentrations of analytes down to a monolayer can be detected by refractive index sensing and identified by their spectral fingerprints with a standard mid-infrared lab spectrometer.

  11. Graphene nanomesh as highly sensitive chemiresistor gas sensor

    PubMed Central

    Paul, Rajat Kanti; Badhulika, Sushmee; Saucedo, Nuvia M.; Mulchandani, Ashok

    2016-01-01

    Graphene is a one atom thick carbon allotrope with all surface atoms that has attracted significant attention as a promising material as the conduction channel of a field-effect transistor and chemical field-effect transistor sensors. However, the zero bandgap of semimetal graphene still limits its application for these devices. In this work, ethanol-chemical vapor deposition (CVD) grown p-type semiconducting large-area monolayer graphene film was patterned into nanomesh by the combination of nanosphere lithography and reactive ion etching and evaluated as field-effect transistor and chemiresistor gas sensors. The resulting neck-width of the synthesized nanomesh was about ~20 nm comprised of the gap between polystyrene spheres that was formed during the reactive ion etching process. The neck-width and the periodicities of the graphene nanomesh could be easily controlled depending the duration/power of RIE and the size of PS nanospheres. The fabricated GNM transistor device exhibited promising electronic properties featuring high drive current and ION/IOFF ratio of about 6, significantly higher than its film counterpart. Similarly, when applied as chemiresistor gas sensor at room temperature, the graphene nanomesh sensor showed excellent sensitivity towards NO2 and NH3, significantly higher than their film counterparts. The ethanol-based graphene nanomesh sensors exhibited sensitivities of about 4.32%/ppm in NO2 and 0.71%/ppm in NH3 with limit of detections of 15 ppb and 160 ppb, respectively. Our demonstrated studies on controlling the neck width of the nanomesh would lead to further improvement of graphene-based transistors and sensors. PMID:22931286

  12. High sensitivity dynamic spectral search for flare star radio

    NASA Technical Reports Server (NTRS)

    Abada-Simon, M.; Lecacheux, A.; Louarn, P.; Dulk, G. A.; Belkora, L.; Bookbinder, J. A.; Rosolen, C.

    1994-01-01

    We observed ten well-known flare stars with the Arcibo radio telescope at 1.4 GHz and 5 GHz, using a special observing technique to discriminate between real flares and radio freqeuncy interference. With a high sensitivity of 5.5 K/Jy at 1.4 GHz when averaged over a 50 MHz band, we are able to recognize flux enhancements as weak as approximately 6 mJy above the sky background variations. In about 85 hours of observation, about a dozen bursts were detected, only from AD Leo. All had flux densities lower than 70 mJy, which probably explains their lack of fine structures (except for the strongest one), such as were reported in the literature for stronger flares. Half of the bursts that we recorded are 100% circularly polarized, and half are not circularly polarized. Our results are a first attempt of reliable statistics on dMe flare rates at 1.4 GHz. The high brightness temperatures we infer for the observed bursts are interpreted in terms of coherent emission processes, either the cyclotron maser instability or plasma radiation. Efficiencies are comparable to those of solar or planetary radio emissions in the case of the cyclotron maser, and higher than the solar efficiency in the case of plasma radiation, with the caveat that there are great uncertainties in the coronal model and the source size.

  13. High sensitivity, low power, microfabricated electrochemical sensor for CO

    SciTech Connect

    Neuzil, P.; Kayvani, D.; Maclay, G.J.

    1996-12-31

    CO is a toxic byproduct of incomplete combustion. Improperly vented fireplaces and faulty furnaces cause a estimated 400 deaths in the US each year. The presence of high CO levels may also indicate the presence of a fire. Hence, improved CO detection is of great interest and in the last several years commercial CO detectors have been released. The two most common methods of CO detection in commercial systems for residential use are (1) optical colorometric method, and (2) tin oxide sensor. The colorometric method has the advantage of low power, but the devices tend to give an alarm condition when exposed to low CO levels for a long time period, are difficult to reset, and have a lifetime of about 1 year. The tin oxide sensors have limited stability and high power requirement since the sensor must be heated. There is a need for a stable, sensitive, low power, low cost CO sensor. The authors have developed a planar amperometric sensor for CO detection using microfabrication technology.

  14. Conducting polymer nanofibers for high sensitivity detection of chemical analytes.

    NASA Astrophysics Data System (ADS)

    Kumar, Abhishek; Leshchiner, Ignaty; Nagarajan, Subhalakshmi; Nagarajan, Ramaswamy; Kumar, Jayant

    2008-03-01

    Possessing large surface area materials is vital for high sensitivity detection of analyte. We report a novel, inexpensive and simple technique to make high surface area sensing interfaces using electrospinning. Conducting polymers (CP) nanotubes were made by electrospinning a solution of a catalyst (ferric tosylate) along with poly (lactic acid), which is an environment friendly biodegradable polymer. Further vapor deposition polymerization of the monomer ethylenedioxy thiophene (EDOT) on the nanofiber surface yielded poly (EDOT) covered fibers. X-ray photo electron spectroscopy (XPS) study reveals the presence of PEDOT predominantly on the surface of nanofibers. Conducting nanotubes had been received by dissolving the polymer in the fiber core. By a similar technique we had covalently incorporated fluorescent dyes on the nanofiber surface. The materials obtained show promise as efficient sensing elements. UV-Vis characterization confirms the formation of PEDOT nanotubes and incorporation of chromophores on the fiber surface. The morphological characterization was carried out using scanning electron microscopy (SEM) and transmission electron microscopy (TEM).

  15. Comparing standard Bonner spheres and high-sensitivity Bonner cylinders.

    PubMed

    Lee, Kuo-Wei; Yuan, Ming-Chen; Jiang, Shiang-Huei; Sheu, Rong-Jiun

    2014-10-01

    Standard Bonner spheres and proposed high-sensitivity Bonner cylinders were calibrated in a neutron calibration room, using a (252)Cf source. The Bonner sphere system consists of 11 polyethylene (PE) spheres of various diameters and 4 extended spheres that comprise embedded metal shells. Similar to the design of Bonner spheres, a set of Bonner cylinders was assembled using a large cylindrical (3)He tube as the central probe, which was wrapped using various thicknesses of PE. A layer of lead was employed inside one of the PE cylinders to increase the detection efficiency of high-energy neutrons. The central neutron probe used in the Bonner cylinders exhibited an efficiency of ∼17.9 times higher than that of the Bonner spheres. However, compared with the Bonner spheres, the Bonner cylinders are not fully symmetric in their geometry, exhibiting angular dependence in their responses to incoming neutrons. Using a series of calculations and measurements, this study presents a systematic comparison between Bonner spheres and cylinders in terms of their response functions, detection efficiencies, angular dependences and spectrum unfolding.

  16. How One Historically Underperforming Rural and Highly Diverse High School Achieved a Successful Turnaround

    ERIC Educational Resources Information Center

    Maxwell, Gerri M.; Huggins, Kristin S.; Scheurich, James J.

    2010-01-01

    "Central High School," a rural school composed largely of students of color from low income homes, experienced a quick, remarkable turnaround of student academic success, measured by State and Federal accountability standards. This turnaround began with an external restructuring grant initiative that required a state-approved external consultant.…

  17. A general strategy to achieve ultra-high gene transfection efficiency using lipid-nanoparticle composites.

    PubMed

    Vankayala, Raviraj; Chiang, Chi-Shiun; Chao, Jui-I; Yuan, Chiun-Jye; Lin, Shyr-Yeu; Hwang, Kuo Chu

    2014-09-01

    Gene therapy provides a new hope for previously "incurable" diseases. Low gene transfection efficiency, however, is the bottle-neck to the success of gene therapy. It is very challenging to develop non-viral nanocarriers to achieve ultra-high gene transfection efficiencies. Herein, we report a novel design of "tight binding-but-detachable" lipid-nanoparticle composite to achieve ultrahigh gene transfection efficiencies of 60∼82%, approaching the best value (∼90%) obtained using viral vectors. We show that Fe@CNPs nanoparticles coated with LP-2000 lipid molecules can be used as gene carriers to achieve ultra-high (60-80%) gene transfection efficiencies in HeLa, U-87MG, and TRAMP-C1 cells. In contrast, Fe@CNPs having surface-covalently bound N,N,N-trimethyl-N-2-methacryloxyethyl ammonium chloride (TMAEA) oligomers can only achieve low (23-28%) gene transfection efficiencies. Similarly ultrahigh gene transfection/expression was also observed in zebrafish model using lipid-coated Fe@CNPs as gene carriers. Evidences for tight binding and detachability of DNA from lipid-nanoparticle nanocarriers will be presented. PMID:24973297

  18. A general strategy to achieve ultra-high gene transfection efficiency using lipid-nanoparticle composites.

    PubMed

    Vankayala, Raviraj; Chiang, Chi-Shiun; Chao, Jui-I; Yuan, Chiun-Jye; Lin, Shyr-Yeu; Hwang, Kuo Chu

    2014-09-01

    Gene therapy provides a new hope for previously "incurable" diseases. Low gene transfection efficiency, however, is the bottle-neck to the success of gene therapy. It is very challenging to develop non-viral nanocarriers to achieve ultra-high gene transfection efficiencies. Herein, we report a novel design of "tight binding-but-detachable" lipid-nanoparticle composite to achieve ultrahigh gene transfection efficiencies of 60∼82%, approaching the best value (∼90%) obtained using viral vectors. We show that Fe@CNPs nanoparticles coated with LP-2000 lipid molecules can be used as gene carriers to achieve ultra-high (60-80%) gene transfection efficiencies in HeLa, U-87MG, and TRAMP-C1 cells. In contrast, Fe@CNPs having surface-covalently bound N,N,N-trimethyl-N-2-methacryloxyethyl ammonium chloride (TMAEA) oligomers can only achieve low (23-28%) gene transfection efficiencies. Similarly ultrahigh gene transfection/expression was also observed in zebrafish model using lipid-coated Fe@CNPs as gene carriers. Evidences for tight binding and detachability of DNA from lipid-nanoparticle nanocarriers will be presented.

  19. CMOS Amperometric ADC With High Sensitivity, Dynamic Range and Power Efficiency for Air Quality Monitoring.

    PubMed

    Li, Haitao; Boling, C Sam; Mason, Andrew J

    2016-08-01

    Airborne pollutants are a leading cause of illness and mortality globally. Electrochemical gas sensors show great promise for personal air quality monitoring to address this worldwide health crisis. However, implementing miniaturized arrays of such sensors demands high performance instrumentation circuits that simultaneously meet challenging power, area, sensitivity, noise and dynamic range goals. This paper presents a new multi-channel CMOS amperometric ADC featuring pixel-level architecture for gas sensor arrays. The circuit combines digital modulation of input currents and an incremental Σ∆ ADC to achieve wide dynamic range and high sensitivity with very high power efficiency and compact size. Fabricated in 0.5 [Formula: see text] CMOS, the circuit was measured to have 164 dB cross-scale dynamic range, 100 fA sensitivity while consuming only 241 [Formula: see text] and 0.157 [Formula: see text] active area per channel. Electrochemical experiments with liquid and gas targets demonstrate the circuit's real-time response to a wide range of analyte concentrations. PMID:27352395

  20. A highly sensitive magnetic biosensor for detection and quantification of anticancer drugs tagged to superparamagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Wingo, J.; Devkota, J.; Mai, T. T. T.; Nguyen, X. P.; Mukherjee, P.; Srikanth, H.; Phan, M. H.; Vietnam Academy of Science and Technology Collaboration; University of South Florida Team

    2014-03-01

    A precise detection of low concentrations of biomolecules attached to magnetic nanoparticles in complex biological systems is a challenging task and requires biosensors with improved sensitivity. Here, we present a highly sensitive magnetic biosensor based on the magneto-reactance (MX) effect of a Co65Fe4Ni2Si15B14 amorphous ribbon with nanohole-patterned surface for detection and quantification of anticancer drugs (Curcumin) tagged to Fe3O4 nanoparticles. The detection and quantification of Curcumin were assessed by the change in MX of the ribbon subject to varying concentrations of the functionalized Fe3O4 nanoparticles. A high capacity of the MX-based biosensor in quantitative analysis of the nanoparticles was achieved in the range of 0 - 50 ng/ml, beyond which the detection sensitivity (η) remained unchanged. The η of the biosensor reached an extremely high value of 30%, which is about 4-5 times higher than that of a magneto-impedance (MI) based biosensor. This biosensor is well suited for detection of low-concentration magnetic biomarkers in biological systems. This work was supported by was supported by the Florida Cluster for Advanced Smart Sensor Technologies, USAMRMC (Grant # W81XWH-07-1-0708), and the NSF-funded REU program at the USF.

  1. A highly sensitive magnetic biosensor for detection and quantification of anticancer drugs tagged to superparamagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Devkota, J.; Wingo, J.; Mai, T. T. T.; Nguyen, X. P.; Huong, N. T.; Mukherjee, P.; Srikanth, H.; Phan, M. H.

    2014-05-01

    We report on a highly sensitive magnetic biosensor based on the magneto-reactance (MX) effect of a Co65Fe4Ni2Si15B14 amorphous ribbon with a nanohole-patterned surface for detection and quantification of anticancer drugs (Curcumin) tagged to superparamagnetic (Fe3O4) nanoparticles. Fe3O4 nanoparticles (mean size, ˜10 nm) were first coated with Alginate, and Curcumin was then tagged to the nanoparticles. The detection and quantification of Curcumin were assessed by the change in MX of the ribbon subject to varying concentrations of the Fe3O4 nanoparticles to which Curcumin was tagged. A high capacity of the MX-based biosensor in quantitative analysis of Curcumin-loaded Fe3O4 nanoparticles was achieved in the range of 0-50 ng/ml, beyond which the detection sensitivity of the sensor remained unchanged. The detection sensitivity of the biosensor reached an extremely high value of 30%, which is about 4-5 times higher than that of a magneto-impedance (MI) based biosensor. This biosensor is well suited for detection of low-concentration magnetic biomarkers in biological systems.

  2. A highly sensitive and flexible pressure sensor with electrodes and elastomeric interlayer containing silver nanowires.

    PubMed

    Wang, Jun; Jiu, Jinting; Nogi, Masaya; Sugahara, Tohru; Nagao, Shijo; Koga, Hirotaka; He, Peng; Suganuma, Katsuaki

    2015-02-21

    The next-generation application of pressure sensors is gradually being extended to include electronic artificial skin (e-skin), wearable devices, humanoid robotics and smart prosthetics. In these advanced applications, high sensing capability is an essential feature for high performance. Although surface patterning treatments and some special elastomeric interlayers have been applied to improve sensitivity, the process is complex and this inevitably raises the cost and is an obstacle to large-scale production. In the present study a simple printing process without complex patterning has been used for constructing the sensor, and an interlayer is employed comprising elastomeric composites filled with silver nanowires. By increasing the relative permittivity, εr, of the composite interlayer induced by compression at high nanowire concentration, it has been possible to achieve a maximum sensitivity of 5.54 kPa(-1). The improvement in sensitivity did not sacrifice or undermine the other features of the sensor. Thanks to the silver nanowire electrodes, the sensor is flexible and stable after 200 cycles at a bending radius of 2 mm, and exhibits outstanding reproducibility without hysteresis under similar pressure pulses. The sensor has been readily integrated onto an adhesive bandage and has been successful in detecting human movements. In addition to measuring pressure in direct contact, non-contact pressures such as air flow can also be detected.

  3. Highly sensitive detection of proteins and bacteria in aqueous solution using surface-enhanced Raman scattering and optical fibers.

    PubMed

    Yang, Xuan; Gu, Claire; Qian, Fang; Li, Yat; Zhang, Jin Z

    2011-08-01

    We report the detection of the proteins lysozyme and cytochrome c as well as the live bacterial cells of Shewanella oneidensis MR-1 in aqueous solutions with sensitivities order(s) of magnitude higher than those previously reported. Two highly sensitive surface-enhanced Raman scattering (SERS)-based biosensors using optical fibers have been employed for such label-free macromolecule detections. The first sensor is based on a tip-coated multimode fiber (TCMMF) with a double-substrate "sandwich" structure, and a detection limit of 0.2 μg/mL is achieved in protein detections. The second sensor is based on a liquid core photonic crystal fiber (LCPCF) with a better confinement of light inside the fiber core, and a detection limit of 10(6) cells/mL is achieved for the bacteria detection. Both SERS biosensors show great potential for highly sensitive and molecule-specific detection and identification of biomolecules. PMID:21692506

  4. Solvent additive to achieve highly ordered nanostructural semicrystalline DPP copolymers: toward a high charge carrier mobility.

    PubMed

    An, Tae Kyu; Kang, Il; Yun, Hui-jun; Cha, Hyojung; Hwang, Jihun; Park, Seonuk; Kim, Jiye; Kim, Yu Jin; Chung, Dae Sung; Kwon, Soon-Ki; Kim, Yun-Hi; Park, Chan Eon

    2013-12-23

    A facile spin-coating method in which a small percentage of the solvent additive, 1-chloronaphthalene (CN), is found to increase the drying time during film deposition, is reported. The field-effect mobility of a PDPPDBTE film cast from a chloroform-CN mixed solution is 0.46 cm(2) V(-1) s(-1). The addition of CN to the chloroform solution facilitates the formation of highly crystalline polymer structures. PMID:24115273

  5. High sensitivity refractive index sensor based on a tapered small core single-mode fiber structure.

    PubMed

    Liu, Dejun; Mallik, Arun Kumar; Yuan, Jinhui; Yu, Chongxiu; Farrell, Gerald; Semenova, Yuliya; Wu, Qiang

    2015-09-01

    A high sensitivity refractive index (RI) sensor based on a tapered small core single-mode fiber (SCSMF) structure sandwiched between two traditional single-mode fibers (SMF28) is reported. The microheater brushing technique was employed to fabricate the tapered fiber structures with different waist diameters of 12.5, 15.0, and 18.8 μm. Experiments demonstrate that the fiber sensor with a waist diameter of 12.5 μm offers the best sensitivity of 19212.5  nm/RIU (RI unit) in the RI range of 1.4304 to 1.4320. All sensors fabricated in this Letter show good linearity in terms of the spectral wavelength shift versus changes in RI. Furthermore, the sensor with the best sensitivity to RI was also used to measure relative humidity (RH) without any coating materials applied to the fiber surface. Experimental results show that the spectral wavelength shift changes exponentially as the RH varies from 60% to 95%. A maximum sensitivity of 18.3 nm per relative humidity unit (RHU) was achieved in the RH range of 90.4% to 94.5% RH. PMID:26368738

  6. Challenges to achievement of metal sustainability in our high-tech society

    SciTech Connect

    Izatt, Reed M.; Izatt, Steven R.; Bruening, Ronald L.; Izatt, Neil; Moyer, Bruce A

    2014-01-01

    Achievement of sustainability in metal life cycles from mining of virgin ore to consumer and industrial devices to end-of-life products requires greatly increased recycling and improved processing of metals. Electronic and other high-tech products containing precious, toxic, and specialty metals usually have short lifetimes and low recycling rates. Products containing these metals generally are incinerated, discarded as waste in landfills, or dismantled in informal recycling using crude and environmentally irresponsible procedures. Low metal recycling rates coupled with increasing demand for products containing them necessitate increased mining with attendant environmental, health, energy, water, and carbon-footprint consequences. In this tutorial review, challenges to achieving metal sustainability in present high-tech society are presented; health, environmental, and economic incentives for various stakeholders to improve metal sustainability are discussed; a case for technical improvements in separations technology, especially employing molecular recognition, is given; and global consequences of continuing on the present path are examined.

  7. Highly sensitive and multiplexed platforms for allergy diagnostics

    NASA Astrophysics Data System (ADS)

    Monroe, Margo R.

    Allergy is a disorder of the immune system caused by an immune response to otherwise harmless environmental allergens. Currently 20% of the US population is allergic and 90% of pediatric patients and 60% of adult patients with asthma have allergies. These percentages have increased by 18.5% in the past decade, with predicted similar trends for the future. Here we design sensitive, multiplexed platforms to detect allergen-specific IgE using the Interferometric Reflectance Imaging Sensor (IRIS) for various clinical settings. A microarray platform for allergy diagnosis allows for testing of specific IgE sensitivity to a multitude of allergens, while requiring only small volumes of patient blood sample. However, conventional fluorescent microarray technology is limited by i) the variation of probe immobilization, which hinders the ability to make quantitative, assertive, and statistically relevant conclusions necessary in immunodiagnostics and ii) the use of fluorophore labels, which is not suitable for some clinical applications due to the tendency of fluorophores to stick to blood particulates and require daily calibration methods. This calibrated fluorescence enhancement (CaFE) method integrates the low magnification modality of IRIS with enhanced fluorescence sensing in order to directly correlate immobilized probe (major allergens) density to allergen-specific IgE in patient serum. However, this platform only operates in processed serum samples, which is not ideal for point of care testing. Thus, a high magnification modality of IRIS was adapted as an alternative allergy diagnostic platform to automatically discriminate and size single nanoparticles bound to specific IgE in unprocessed, characterized human blood and serum samples. These features make IRIS an ideal candidate for clinical and diagnostic applications, such a POC testing. The high magnification (nanoparticle counting) modality in conjunction with low magnification of IRIS in a combined instrument

  8. A novel light tracing system with high-precision and high-sensitivity sensors setup

    NASA Astrophysics Data System (ADS)

    Lin, Chern-Sheng; Wu, Pin Yi; Tsai, Jen Min; Tseng, Yu Hung; Chen, Hsin-Hung; Hwang, Jiann-Lih

    2013-11-01

    This paper presents a novel light source tracing system, which is comprised of a light-tracing board, with four photo-sensors of different incline angles, correspondingly disposed on its four edges, which are adjustable according to the movement range of the light source in order to achieve light-tracing purposes. This system introduces the algorithm of four-edge-sensors with servo motors in each site to improve sensor's sensitivity. The measurement values of light perception can be feedback to the programmable logic controller by wireless transceiver module. After proportional-integral-derivative operation, the system can obtain the situation of light source. In a normal mode, the light source movement range is large, the range of the incline angle of the light sensors are also set to large to obtain wide detection angle. But in a locking mode, the incline angle of the light sensing plane decreases, thus, the measurement range reduces, and the sensitivity is higher.

  9. DEER Sensitivity between Iron Centers and Nitroxides in Heme-Containing Proteins Improves Dramatically Using Broadband, High-Field EPR

    PubMed Central

    2016-01-01

    This work demonstrates the feasibility of making sensitive nanometer distance measurements between Fe(III) heme centers and nitroxide spin labels in proteins using the double electron–electron resonance (DEER) pulsed EPR technique at 94 GHz. Techniques to measure accurately long distances in many classes of heme proteins using DEER are currently strongly limited by sensitivity. In this paper we demonstrate sensitivity gains of more than 30 times compared with previous lower frequency (X-band) DEER measurements on both human neuroglobin and sperm whale myoglobin. This is achieved by taking advantage of recent instrumental advances, employing wideband excitation techniques based on composite pulses and exploiting more favorable relaxation properties of low-spin Fe(III) in high magnetic fields. This gain in sensitivity potentially allows the DEER technique to be routinely used as a sensitive probe of structure and conformation in the large number of heme and many other metalloproteins. PMID:27035368

  10. DEER Sensitivity between Iron Centers and Nitroxides in Heme-Containing Proteins Improves Dramatically Using Broadband, High-Field EPR.

    PubMed

    Motion, Claire L; Lovett, Janet E; Bell, Stacey; Cassidy, Scott L; Cruickshank, Paul A S; Bolton, David R; Hunter, Robert I; El Mkami, Hassane; Van Doorslaer, Sabine; Smith, Graham M

    2016-04-21

    This work demonstrates the feasibility of making sensitive nanometer distance measurements between Fe(III) heme centers and nitroxide spin labels in proteins using the double electron-electron resonance (DEER) pulsed EPR technique at 94 GHz. Techniques to measure accurately long distances in many classes of heme proteins using DEER are currently strongly limited by sensitivity. In this paper we demonstrate sensitivity gains of more than 30 times compared with previous lower frequency (X-band) DEER measurements on both human neuroglobin and sperm whale myoglobin. This is achieved by taking advantage of recent instrumental advances, employing wideband excitation techniques based on composite pulses and exploiting more favorable relaxation properties of low-spin Fe(III) in high magnetic fields. This gain in sensitivity potentially allows the DEER technique to be routinely used as a sensitive probe of structure and conformation in the large number of heme and many other metalloproteins. PMID:27035368

  11. Experimental Realisation of High-sensitivity Laboratory X-ray Grating-based Phase-contrast Computed Tomography

    PubMed Central

    Birnbacher, Lorenz; Willner, Marian; Velroyen, Astrid; Marschner, Mathias; Hipp, Alexander; Meiser, Jan; Koch, Frieder; Schröter, Tobias; Kunka, Danays; Mohr, Jürgen; Pfeiffer, Franz; Herzen, Julia

    2016-01-01

    The possibility to perform high-sensitivity X-ray phase-contrast imaging with laboratory grating-based phase-contrast computed tomography (gbPC-CT) setups is of great interest for a broad range of high-resolution biomedical applications. However, achieving high sensitivity with laboratory gbPC-CT setups still poses a challenge because several factors such as the reduced flux, the polychromaticity of the spectrum, and the limited coherence of the X-ray source reduce the performance of laboratory gbPC-CT in comparison to gbPC-CT at synchrotron facilities. In this work, we present our laboratory X-ray Talbot-Lau interferometry setup operating at 40 kVp and describe how we achieve the high sensitivity yet unrivalled by any other laboratory X-ray phase-contrast technique. We provide the angular sensitivity expressed via the minimum resolvable refraction angle both in theory and experiment, and compare our data with other differential phase-contrast setups. Furthermore, we show that the good stability of our high-sensitivity setup allows for tomographic scans, by which even the electron density can be retrieved quantitatively as has been demonstrated in several preclinical studies. PMID:27040492

  12. High-fidelity simulation: Assessment of student nurses' team achievements of clinical judgment.

    PubMed

    Hallin, Karin; Bäckström, Britt; Häggström, Marie; Kristiansen, Lisbeth

    2016-07-01

    Nursing educators have the challenge of preparing nursing students to handle complex patient care situations in real life, but much remains unknown about the ability to make clinical judgments. In this study, high-fidelity simulation (HFS) was used at a Swedish university to find answers about pre-licensure nursing students' success in clinical judgment in terms of team ability and relationships with theoretical achievements, and personal and scenario circumstances. The matrix Lasater Clinical Judgment Rubric (LCJR) was used to analyze and score the students' ability in teams to notice, interpret and respond to complex care situations. Overall, the results showed the student teams in their first meeting with HFS in a complex care situation achieved low clinical judgment points; most teams were in the stages of Beginning and Developing. For attaining high team achievements the majority of the students in the team should theoretically be "high performance". Being observers and having HFS experience before nursing education was significant too. However, age, health care experience, and assistant nurse degrees were of secondary importance. Further research at universities regionally, nationally, and internationally is needed. PMID:27428686

  13. Nutrition and education. III. Educational achievement and food habits of Chilean elementary and high school graduates.

    PubMed

    Ivanovic, D; Vásquez, M; Aguayo, M; Ballester, D; Marambio, M; Zacarías, I

    1992-03-01

    The objective of this study was to correlate the educational achievement (EA) of Chilean elementary and high-school graduates with their food habits. For this purpose, a random sample of 550 schoolers from the Metropolitan Area of Santiago, Chile, graduating from elementary and high school (1:1) of both sexes (1:1), from public and private schools and from high, medium and low socioeconomic status (SES) (1:1:1), was selected. Food habits were determined through a specially designed questionnaire and defined as the frequency of consumption of the food groups, expressed as days per week. The EA was established through the Achievement Evaluation Program (AEP) and Academic Aptitude Test (AAT) in elementary-and high-school graduates-, respectively. Results revealed that EA was found significantly and positively correlated with the frequency of consumption of dairy products, meat products and eggs, in both elementary and high school graduates. A significant and inverse correlation between EA and the frequency of vegetables and fruits consumption was observed in both educational levels, and with miscellaneous products, only in elementary school graduates. Food habits explained 24.4% and 16.6% of the EA variance, in elementary and high school graduates, respectively. The frequency of consumption of dairy products was the independent variable with the greatest explanatory power in EA variance (approximately above 70% of the explained variance). These results are important to consider for educational planning focused on the School Feeding Program.

  14. Achieving high performance polymer optoelectronic devices for high efficiency, long lifetime and low fabrication cost

    NASA Astrophysics Data System (ADS)

    Huang, Jinsong

    This thesis described three types of organic optoelectronic devices: polymer light emitting diodes (PLED), polymer photovoltaic solar cell, and organic photo detector. The research in this work focuses improving their performance including device efficiency, operation lifetime simplifying fabrication process. With further understanding in PLED device physics, we come up new device operation model and improved device architecture design. This new method is closely related to understanding of the science and physics at organic/metal oxide and metal oxide/metal interface. In our new device design, both material and interface are considered in order to confine and balance all injected carriers, which has been demonstrated very be successful in increasing device efficiency. We created two world records in device efficiency: 18 lm/W for white emission fluorescence PLED, 22 lm/W for red emission phosphorescence PLED. Slow solvent drying process has been demonstrated to significantly increase device efficiency in poly(3-hexylthiophene) (P3HT) and [6,6]-phenyl C 61-butyric acid methyl ester (PCBM) mixture polymer solar cell. From the mobility study by time of flight, the increase of efficiency can be well correlated to the improved carrier transport property due to P3HT crystallization during slow solvent drying. And it is found that, similar to PLED, balanced carrier mobility is essential in high efficient polymer solar cell. There is also a revolution in our device fabrication method. A unique device fabrication method is presented by an electronic glue based lamination process combined with interface modification as a one-step polymer solar cell fabrication process. It can completely skip the thermal evaporation process, and benefit device lifetime by several merits: no air reactive. The device obtained is metal free, semi-transparent, flexible, self-encapsulated, and comparable efficiency with that by regular method. We found the photomultiplication (PM) phenomenon in C

  15. ASIC for High Rate 3D Position Sensitive Detectors

    SciTech Connect

    Vernon, E.; De Geronimo, G.; Ackley, K.; Fried, J.; He, Z.; Herman, C.; Zhang, F.

    2010-06-16

    We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.

  16. Physical activity and high-sensitivity C-reactive protein.

    PubMed

    Plaisance, Eric P; Grandjean, Peter W

    2006-01-01

    Cardiovascular disease (CVD) remains one of the leading causes of death and disability in developed countries around the world despite the documented success of lifestyle and pharmacological interventions. This illustrates the multifactorial nature of atherosclerosis and the use of novel inflammatory markers as an adjunct to risk factor reduction strategies. As evidence continues to accumulate that inflammation is involved in all stages of the development and progression of atherosclerosis, markers of inflammation such as high-sensitivity C-reactive protein (CRP) may provide additional information regarding the biological status of the atherosclerotic lesion. Recent investigations suggest that physical activity reduces CRP levels. Higher levels of physical activity and cardiorespiratory fitness are consistently associated with 6-35% lower CRP levels. Longitudinal training studies that have demonstrated reductions in CRP concentrations range from 16% to 41%, an effect that may be independent of baseline levels of CRP, body composition or weight loss. The average change in CRP associated with physical activity appears to be at least as good, if not better, than currently prescribed pharmacological interventions in similar populations. The primary purpose of this review will be to present evidence from both cross-sectional and longitudinal investigations that physical activity lowers CRP levels in a dose-response manner. Finally, this review will examine factors such as body composition, sex, blood sample timing, diet and smoking, which may influence the CRP response to physical activity. PMID:16646631

  17. Improvement of sensitivity in high-resolution Rutherford backscattering spectroscopy

    SciTech Connect

    Hashimoto, H.; Nakajima, K.; Suzuki, M.; Kimura, K.; Sasakawa, K.

    2011-06-15

    The sensitivity (limit of detection) of high-resolution Rutherford backscattering spectroscopy (HRBS) is mainly determined by the background noise of the spectrometer. There are two major origins of the background noise in HRBS, one is the stray ions scattered from the inner wall of the vacuum chamber of the spectrometer and the other is the dark noise of the microchannel plate (MCP) detector which is commonly used as a focal plane detector of the spectrometer in HRBS. In order to reject the stray ions, several barriers are installed inside the spectrometer and a thin Mylar foil is mounted in front of the detector. The dark noise of the MCP detector is rejected by the coincidence measurement with the secondary electrons emitted from the Mylar foil upon the ion passage. After these improvements, the background noise is reduced by a factor of 200 at a maximum. The detection limit can be improved down to 10 ppm for As in Si at a measurement time of 1 h under ideal conditions.

  18. High sensitivity DNA detection based on regioselectively decorated electrocatalytic nanoparticles.

    PubMed

    Spain, Elaine; Brennan, Eoin; McArdle, Hazel; Keyes, Tia E; Forster, Robert J

    2012-08-01

    Self-assembled monolayers (SAMs) of dodecanethiol have been formed on gold electrodes to produce nanoscale defects. These defects define nucleation sites for the electrodeposition of mushroom shaped platinum nanoparticles (PtNPs). The top surfaces of these PtNPs have been selectively functionalized with single stranded probe DNA. These regioselectively modified particles were desorbed by applying a current jump to yield nanoparticles capable of biorecognition on the top curved side and efficient electrocatalysis on the nonfunctionalized lower surface. A second electrode was functionalized with single stranded capture DNA that has a sequence that is complementary to the pathogen, Staphylococcus aureus but leaves a section of the target available to bind the probe strand immobilized on the PtNPs. Following hybridization of the target and capture strands, the surface was exposed to the probe DNA labeled electrocatalytic PtNPs. Target binding was detected by monitoring the current associated with the reduction of hydrogen peroxide in a solution of 0.01 M H(2)SO(4). Calibration plots of the log[DNA] versus faradaic current were linear from 10 pM to 1 μM and picomolar concentrations could be detected without the need for amplification of the target, for example, using PCR or NASBA. As well as a wide dynamic range, this detection strategy has an excellent ability to discriminate DNA mismatches and a high analytical sensitivity. PMID:22747434

  19. Ultra-high sensitivity imaging of cancer using SERRS nanoparticles

    NASA Astrophysics Data System (ADS)

    Kircher, Moritz F.

    2016-05-01

    "Surface-enhanced Raman spectroscopy" (SERS) nanoparticles have gained much attention in recent years for in silico, in vitro and in vivo sensing applications. Our group has developed novel generations of biocompatible "surfaceenhanced resonance Raman spectroscopy" (SERRS) nanoparticles as novel molecular imaging agents. Via rigorous optimization of the different variables contributing to the Raman enhancement, we were able to design SERRS nanoparticles with so far unprecedented sensitivity of detection under in vivo imaging conditions (femto-attomolar range). This has resulted in our ability to visualize, with a single nanoparticle, many different cancer types (after intravenous injection) in mouse models. The cancer types we have tested so far include brain, breast, esophagus, stomach, pancreas, colon, sarcoma, and prostate cancer. All mouse models used are state-of-the-art and closely mimic the tumor biology in their human counterparts. In these animals, we were able to visualize not only the bulk tumors, but importantly also microscopic extensions and locoregional satellite metastases, thus delineating for the first time the true extent of tumor spread. Moreover, the particles enable the detection of premalignant lesions. Given their inert composition they are expected to have a high chance for clinical translation, where we envision them to have an impact in various scenarios ranging from early detection, image-guidance in open or minimally invasive surgical procedures, to noninvasive imaging in conjunction with spatially offset (SESORS) Raman detection devices.

  20. High resolution, position sensitive detector for energetic particle beams

    NASA Astrophysics Data System (ADS)

    Marsh, E. P.; Strathman, M. D.; Reed, D. A.; Morse, D. H.; Pontau, A. E.; Odom, R. W.

    1993-05-01

    The performance and design of an imaging position sensitive, particle beam detector will be presented. The detector is minimally invasive, operates over a wide dynamic range (> 10 10), and exhibits high spatial resolution. The secondary electrons produced when a particle beam passes through a thin foil are imaged using stigmatic ion optics onto a two-dimensional imaging detector. Due to the low scattering cross section of the 6 nm carbon foil the detector is a minimal perturbation on the primary beam. A prototype detector with an image resolution of approximately 5 μm for a field of view of 1 mm has been reported [R.W. Odom, M.D. Strathman, S.E. Buttrill, Jr., and S.M. Bauman, Nucl. Instr. and Meth. B44 (1990) 465]. A higher resolution detector for imaging small beams (< 50 μm) with an image resolution of better than 0.5 μm has since been developed and its design is presented.

  1. Recognizing internet addiction: prevalence and relationship to academic achievement in adolescents enrolled in urban and rural Greek high schools.

    PubMed

    Stavropoulos, Vasilis; Alexandraki, Kiriaki; Motti-Stefanidi, Frosso

    2013-06-01

    This study aims: a) to estimate the prevalence of internet addiction among adolescents of urban and rural areas in Greece, b) to examine whether the Internet Addiction Test cut-off point is applicable to them and c) to investigate the phenomenon's association with academic achievement. Participants were 2090 adolescents (mean age 16, 1036 males, 1050 females). Young's (1998) Internet Addiction Test and her Diagnostic Questionnaire were applied. School records' grades were retrieved. A 3.1% prevalence revealed, while boys {F (1, 1642) = 6.207, p < .05}, urban residents {F (1, 1642) = 5.53, p > .05} and academic track high school students {F (1, 1642) = 5.30, p < .05} were at higher risk. An Internet Addiction Test score of 51 points (sample's mean = 27.69, SD = 17.38) was proposed as the optimal cut-off point combining high sensitivity (98%) and specificity (91%). Finally, findings illustrated the syndrome's relation to worse academic achievement {F (1, 1725) = 0.93, p > .05}.

  2. Dry Blending to Achieve Isotopic Dilution of Highly Enriched Uranium Oxide Materials

    SciTech Connect

    Henry, Roger Neil; Chipman, Nathan Alan; Rajamani, R. K.

    2001-04-01

    The end of the cold war produced large amounts of excess fissile materials in the United States and Russia. The Department of Energy has initiated numerous activities to focus on identifying material management strategies for disposition of these excess materials. To date, many of these planning strategies have included isotopic dilution of highly enriched uranium as a means of reducing the proliferation and safety risks. Isotopic dilution by dry blending highly enriched uranium with natural and/or depleted uranium has been identified as one non-aqueous method to achieve these risk (proliferation and criticality safety) reductions. This paper reviews the technology of dry blending as applied to free flowing oxide materials.

  3. Progress toward achieving high power and high efficiency semipolar LEDs and their characterization

    NASA Astrophysics Data System (ADS)

    Zhong, Hong

    Performance of current commercially available wurtzite nitride based light-emitting diodes (LEDs), grown along the polar (0001) c-plane orientation, is limited by the presence of polarization-related electric fields inside multi-quantum wells (MQWs). The discontinuities in both spontaneous and piezoelectric polarization at the heterointerfaces result in internal electric fields in the quantum wells. These electric fields cause carrier separation [quantum confined Stark effect (QCSE)] and reduce the radiative recombination rate within the quantum wells. One approach to reduce and possibly eliminate the polarization-related effects is to grow III-nitride devices on crystal planes that are inclined with respect to the c-axis, i.e., on semipolar planes. In this dissertation, metalorganic chemical vapor deposition (MOCVD) has been employed for the homoepitaxial growth of GaN based LEDs on semipolar orientations. As a consequence of growing on high-quality bulk GaN substrates, the LEDs have significantly reduced threading dislocation and stacking fault densities, resulting in remarkable improvements in EQE and output power. High efficiency semipolar (1011) violet-blue and blue LEDs have been demonstrated without any intentional effort to enhance the light extraction from those devices. Optimizations of epitaxial structures have led to increased output power and external quantum efficiency. A silicone encapsulated single quantum well blue LED with peak wavelength of 444 nm with output power of 24.3 mW, external quantum efficiency of 43% and luminous efficacy of 75 lm/W (with phosphorescent coating) at 20 mA has been demonstrated. Polarization fields in strained (1011) and (112¯2) InGaN quantum wells have been experimentally determined through bias-dependent optical studies. Our results show that the polarization field flips its direction in semipolar InGaN quantum wells with large inclination angles (i.e. around 60°). This suggests that there exists a polarization

  4. Enhanced Conversion Efficiencies in Dye-Sensitized Solar Cells Achieved through Self-Assembled Platinum(II) Metallacages

    NASA Astrophysics Data System (ADS)

    He, Zuoli; Hou, Zhiqiang; Xing, Yonglei; Liu, Xiaobin; Yin, Xingtian; Que, Meidan; Shao, Jinyou; Que, Wenxiu; Stang, Peter J.

    2016-07-01

    Two-component self-assembly supramolecular coordination complexes with particular photo-physical property, wherein unique donors are combined with a single metal acceptor, can be utilized for many applications including in photo-devices. In this communication, we described the synthesis and characterization of two-component self-assembly supramolecular coordination complexes (SCCs) bearing triazine and porphyrin faces with promising light-harvesting properties. These complexes were obtained from the self-assembly of a 90° Pt(II) acceptor with 2,4,6-tris(4-pyridyl)-1,3,5-triazine (TPyT) or 5,10,15,20-Tetra(4-pyridyl)-21H,23H-porphine (TPyP). The greatly improved conversion efficiencies of the dye-sensitized TiO2 solar cells were 6.79 and 6.08 respectively, while these SCCs were introduced into the TiO2 nanoparticle film photoanodes. In addition, the open circuit voltage (Voc) of dye-sensitized solar cells was also increased to 0.769 and 0.768 V, which could be ascribed to the inhibited interfacial charge recombination due to the addition of SCCs.

  5. Sensitivity improvement of an electrical sensor achieved by control of biomolecules based on the negative dielectrophoretic force.

    PubMed

    Kim, Hye Jin; Kim, Jinsik; Yoo, Yong Kyoung; Lee, Jeong Hoon; Park, Jung Ho; Hwang, Kyo Seon

    2016-11-15

    Effective control of nano-scale biomolecules can enhance the sensitivity and limit of detection of an interdigitated microelectrode (IME) sensor. Manipulation of the biomolecules by dielectrophoresis (DEP), especially the negative DEP (nDEP) force, so that they are trapped between electrodes (sensing regions) was predicted to increase the binding efficiency of the antibody and target molecules, leading to a more effective reaction. To prove this concept, amyloid beta 42 (Aβ42) and prostate specific antigen (PSA) protein were respectively trapped between the sensing region owing to the nDEP force under 5V and 0.05V, which was verified with COMSOL simulation. Using the simulation value, the resistance change (ΔR/Rb) of the IME sensor from the specific antibody-antigen reaction of the two biomolecules and the change in fluorescence intensity were compared in the reference (pDEP) and nDEP conditions. The ΔR/Rb value improved by about 2-fold and 1.66-fold with nDEP compared to the reference condition with various protein concentrations, and these increases were confirmed with fluorescence imaging. Overall, nDEP enhanced the detection sensitivity for Aβ42 and PSA by 128% and 258%, respectively, and the limit of detection improved by up to 2-orders of magnitude. These results prove that DEP can improve the biosensor's performance. PMID:27449966

  6. Enhanced Conversion Efficiencies in Dye-Sensitized Solar Cells Achieved through Self-Assembled Platinum(II) Metallacages

    PubMed Central

    He, Zuoli; Hou, Zhiqiang; Xing, Yonglei; Liu, Xiaobin; Yin, Xingtian; Que, Meidan; Shao, Jinyou; Que, Wenxiu; Stang, Peter J.

    2016-01-01

    Two-component self-assembly supramolecular coordination complexes with particular photo-physical property, wherein unique donors are combined with a single metal acceptor, can be utilized for many applications including in photo-devices. In this communication, we described the synthesis and characterization of two-component self-assembly supramolecular coordination complexes (SCCs) bearing triazine and porphyrin faces with promising light-harvesting properties. These complexes were obtained from the self-assembly of a 90° Pt(II) acceptor with 2,4,6-tris(4-pyridyl)-1,3,5-triazine (TPyT) or 5,10,15,20-Tetra(4-pyridyl)-21H,23H-porphine (TPyP). The greatly improved conversion efficiencies of the dye-sensitized TiO2 solar cells were 6.79 and 6.08 respectively, while these SCCs were introduced into the TiO2 nanoparticle film photoanodes. In addition, the open circuit voltage (Voc) of dye-sensitized solar cells was also increased to 0.769 and 0.768 V, which could be ascribed to the inhibited interfacial charge recombination due to the addition of SCCs. PMID:27404912

  7. Highly Sensitive Dual-Phase Nanoglass-Ceramics Self-Calibrated Optical Thermometer.

    PubMed

    Chen, Daqin; Wan, Zhongyi; Liu, Shen

    2016-04-01

    A strategy to achieve high sensitivity of noncontact optical thermometer via the structure design of nanoglass-ceramic and the usage of Ln(3+) (Ln = Eu, Tb, Dy) luminescence as reference signal and Cr(3+) emission as temperature signal was provided. Specifically, the synthesized dual-phase glass-ceramics were evidenced to enable spatially confined doping of Ln(3+) in the hexagonal GdF3 nanocrystals and Cr(3+) in the cubic Ga2O3 nanoparticles, being beneficial to suppressing detrimental energy transfer between Ln(3+) and Cr(3+) and thus significantly enhancing their luminescence. As a consequence, completely different temperature-sensitive luminescence of Ln(3+)4f → 4f transition and Cr(3+) 3d → 3d transition in the present glass-ceramic resulted in obvious variation of Cr(3+)/Ln(3+) fluorescence intensity ratio with temperature and strikingly high detecting temperature sensitivity of 15-22% per K. We believe that this preliminary study will provide an important advance in exploring other innovative optical thermometry. PMID:26937775

  8. High efficiency polarization-sensitive photovoltaic devices using oriented organic thin film

    NASA Astrophysics Data System (ADS)

    Tanaka, Hideyuki; Yasuda, Takeshi; Fujita, Katsuhiko; Tsutsui, Tetsuo

    2005-10-01

    We report the fabrication of polarization-sensitive photovoltaic devices made of hetero-junction type vacuum-sublimed multilayer films composed of aligned 3,4,9,10-perylenetetracarboxylic-bis-benzimidazole (aligned-PTCBI) and titanyl phthalocyanine (TiOPc). The PTCBI layer was successfully made to be well aligned without losing high photovoltaic power-conversion efficiency. High polarization sensitivity was achieved at around 540 nm. The device configuration was ITO/In/aligned-PTCBI/TiOPc/PEDOT:PSS/Au and the thickness of each layer was optimized for polarization-sensitive photo-detection. The power-conversion efficiencies under the polarized white light parallel and perpendicular to the molecular-orientation axis, through the ITO electrode were 0.78% and 0.45%, respectively. The ratio of short-circuit current, parallel to perpendicular, was 1.66. This device can be used as transparent photo-detectors, because the transmittance of the Au electrode was about 40% at 500-600nm. The short-circuit current ratio was increased to 3.0, when 510nm monochromatic polarized light through the Au electrode was used.

  9. Perovskite nanoparticle-sensitized Ga2O3 nanorod arrays for CO detection at high temperature

    DOE PAGES

    Lin, Hui -Jan; Baltrus, John P.; Gao, Haiyong; Ding, Yong; Nam, Chang -Yong; Ohodnicki, Paul; Gao, Pu -Xian

    2016-04-04

    Here, noble metal nanoparticles are extensively used for sensitizing metal oxide chemical sensors through the catalytic spillover mechanism. However, due to earth-scarcity and high cost of noble metals, finding replacements presents a great economic benefit. Besides, high temperature and harsh environment sensor applications demand material stability under conditions approaching thermal and chemical stability limits of noble metals. In this study, we employed thermally stable perovskite-type La0.8Sr0.2FeO3 (LSFO) nanoparticle surface decoration on Ga2O3 nanorod array gas sensors and discovered an order of magnitude enhanced sensitivity to carbon monoxide at 500 °C. The LSFO nanoparticle catalysts was of comparable performance to thatmore » achieved by Pt nanoparticles, with a much lower weight loading than Pt. Detailed electron microscopy and X-ray photoelectron spectroscopy studies suggested the LSFO nanoparticle sensitization effect is attributed to a spillover-like effect associated with the gas-LSFO-Ga2O3 triple-interfaces that spread the negatively charged surface oxygen ions from LSFO nanoparticles surfaces over to β-Ga2O3 nanorod surfaces with faster surface CO oxidation reactions.« less

  10. Heterogeneity in High Math Achievement across Schools: Evidence from the American Mathematics Competitions. NBER Working Paper No. 18277

    ERIC Educational Resources Information Center

    Ellison, Glenn; Swanson, Ashley

    2012-01-01

    This paper explores differences in the frequency with which students from different schools reach high levels of math achievement. Data from the American Mathematics Competitions is used to produce counts of high-scoring students from more than two thousand public, coeducational, non-magnet, non-charter U.S. high schools. High-achieving students…

  11. Acculturation, Social Support and Academic Achievement of Mexican and Mexican American High School Students: An Exploratory Study.

    ERIC Educational Resources Information Center

    Lopez, Eric J.; Ehly, Stewart; Garcia-Vasquez, Enedina

    2002-01-01

    Concern about the high dropout rate among Mexican American high school students promoted a study to investigate how acculturation and social support influence academic achievement. Students who were highly integrated and strongly bicultural tended to have higher academic achievement. Females tended to have high GPAs; males were slightly more…

  12. High sensitivity Moire interferometry with phase shifting at nano resolution

    NASA Astrophysics Data System (ADS)

    Chen, Bicheng

    Due to insatiate demand for miniaturization of electronics, there is a need for new techniques to measure full-field strain at micro-scale structures. In addition, Micro-Electronic-Mechanical-Systems (MEMS) require a high resolution and high sensitivity material property characterization technique. In this study, a theoretic model for a high sensitivity Moire Interferometry (MI) for measuring nano-scale strain field has been developed. The study also includes the application of the proposed measurement technique for the study of reliability of next generation nano-electronics/power electronics. The study includes both theoretical and experimental work. In the theoretical part, a far field modeling of a Moire Interferometer (MI) using the mode decomposition method is proposed according to the analytical formulation from the scalar diffraction theory. The wave propagation within the defined MI far field domain is solved analytically for a single frequency surface relieved grating structure following the Rayleigh-Sommerfeld formulation under the paraxial approximation. It is shown that the far-field electrical field and the intensity interferogram can be calculated using the mode decomposition method. Furthermore, the near-field (propagation distance < 1 mum) assumptions are validated using exact electromagnetic (EM) theory; and the EM fields are simulated in a few microns region above the surface of the diffraction grating. The study shows that there is a strong correlation (correlation factor R = 0.869) of spatial frequency response between EM field and strain field at the nanoscale. Experimentally, a 164 nm/pixel spatial resolution Moire Interferometer with automated full strain field calculation is proposed. Accurate full strain field maps are generated automatically by a combination of phase shifting technique (temporal data redundancy) and Continuous Wavelet Transform (CWT) (spatial data redundancy). A thermal experiment on BGA packaging is used to demonstrate

  13. Strategies to achieve high-solids enzymatic hydrolysis of dilute-acid pretreated corn stover.

    PubMed

    Geng, Wenhui; Jin, Yongcan; Jameel, Hasan; Park, Sunkyu

    2015-01-01

    Three strategies were presented to achieve high solids loading while maximizing carbohydrate conversion, which are fed-batch, splitting/thickening, and clarifier processes. Enzymatic hydrolysis was performed at water insoluble solids (WIS) of 15% using washed dilute-acid pretreated corn stover. The carbohydrate concentration increased from 31.8 to 99.3g/L when the insoluble solids content increased from 5% to 15% WIS, while the final carbohydrate conversion was decreased from 78.4% to 73.2%. For the fed-batch process, a carbohydrate conversion efficiency of 76.8% was achieved when solid was split into 60:20:20 ratio, with all enzymes added first. For the splitting/thickening process, a carbohydrate conversion of 76.5% was realized when the filtrate was recycled to simulate a steady-state process. Lastly, the clarifier process was evaluated and the highest carbohydrate conversion of 81.4% was achieved. All of these results suggests the possibility of enzymatic hydrolysis at high solids to make the overall conversion cost-competitive.

  14. Highly sensitive magnetic field sensor based on microfiber coupler with magnetic fluid

    SciTech Connect

    Luo, Longfeng; Pu, Shengli Tang, Jiali; Zeng, Xianglong; Lahoubi, Mahieddine

    2015-05-11

    A kind of magnetic field sensor using a microfiber coupler (MFC) surrounded with magnetic fluid (MF) is proposed and experimentally demonstrated. As the MFC is strongly sensitive to the surrounding refractive index (RI) and MF's RI is sensitive to magnetic field, the magnetic field sensing function of the proposed structure is realized. Interrogation of magnetic field strength is achieved by measuring the dip wavelength shift and transmission loss change of the transmission spectrum. The experimental results show that the sensitivity of the sensor is wavelength-dependent. The maximum sensitivity of 191.8 pm/Oe is achieved at wavelength of around 1537 nm in this work. In addition, a sensitivity of −0.037 dB/Oe is achieved by monitoring variation of the fringe visibility. These suggest the potential applications of the proposed structure in tunable all-in-fiber photonic devices such as magneto-optical modulator, filter, and sensing.

  15. High-sensitivity high-throughput chip based biosensor array for multiplexed detection of heavy metals

    NASA Astrophysics Data System (ADS)

    Yan, Hai; Tang, Naimei; Jairo, Grace A.; Chakravarty, Swapnajit; Blake, Diane A.; Chen, Ray T.

    2016-03-01

    Heavy metal ions released into the environment from industrial processes lead to various health hazards. We propose an on-chip label-free detection approach that allows high-sensitivity and high-throughput detection of heavy metals. The sensing device consists of 2-dimensional photonic crystal microcavities that are combined by multimode interferometer to form a sensor array. We experimentally demonstrate the detection of cadmium-chelate conjugate with concentration as low as 5 parts-per-billion (ppb).

  16. Academic achievement in the high school years: the changing role of school engagement.

    PubMed

    Chase, Paul A; Hilliard, Lacey J; Geldhof, G John; Warren, Daniel J A; Lerner, Richard M

    2014-06-01

    School engagement is an important theoretical and practical cornerstone to the promotion of academic accomplishments. This article used a tripartite-behavioral, emotional, and cognitive-model of school engagement to assess the relationship between school engagement and academic success among high school students, and to determine whether a reciprocal relationship exists between these constructs. Data were derived from 710 youth (69% female) who took part in Waves 6 through 8 (Grades 10 through 12) of the 4-H study of positive youth development. Longitudinal confirmatory factor analyses confirmed the invariance of the tripartite model of school engagement. Results of a structural equation model showed that the components of school engagement and academic achievement were mutually predictive and that these predictions varied from grade to grade. Future possibilities for evaluating the relationship between school engagement and academic achievement, as well as the implications for educational policy and practice, are discussed.

  17. Proposed Ultra-High Sensitivity High-Frequency Gravitational Wave Detector

    NASA Astrophysics Data System (ADS)

    Baker, Robert M. L.; Stephenson, Gary V.; Li, Fangyu

    2008-01-01

    The paper discusses the proposed improvement of a High-Frequency Relic Gravitational Wave (HFRGW) detector designed by Li, Baker, Fang, Stephenson and Chen in order to greatly improve its sensitivity. The improved detector is inspired by the Laser Interferometer Gravitational Observatory or LIGO, but is sensitive to the high-frequency end of the gravitational-wave spectrum. As described in prior papers it utilizes the Gertsenshtein effect, which introduces the conversion of gravitational waves to electromagnetic (EM) waves in the presence of a static magnetic field. Such a conversion, if it leads to photons moving in a direction perpendicular to the plane of the EM waves and the magnetic field, will allow for ultra-high sensitivity HFRGW detection. The use of sensitive microwave, single photon detectors such as a circuit QED and/or the Rydberg Atom Cavity Detector, or off-the-shelf detectors, could lead to such detection. When the EM-detection photons are focused at the microwave detectors by fractal-membrane reflectors sensitivity is also improved. Noise sources external to the HFRGW detector will be eliminated by placing a tight mosaic of superconducting tiles (e.g., YBCO) and/or fractal membranes on the interior surface of the detector's cryogenic containment vessel in order to provide a perfect Faraday cage. Internal thermal noise will be eliminated by means of a microwave absorbing (or reflecting) interior enclosure shaped to conform to a high-intensity continuous microwave Gaussian beam (GB), will reduce any background photon flux (BPF) noise radiated normal to the GB's axis. Such BPF will be further attenuated by a series of microwave absorbing baffles forming tunnels to the sensitive microwave detectors on each side of the GB and at right angles to the static magnetic field. A HFGW detector of bandwidth of 1 KHz to 10 KHz or less in the GHz band has been selected. It is concluded that the utilization of the new ultra-high-sensitivity microwave detectors

  18. The effects of modeling instruction on high school physics academic achievement

    NASA Astrophysics Data System (ADS)

    Wright, Tiffanie L.

    The purpose of this study was to explore whether Modeling Instruction, compared to traditional lecturing, is an effective instructional method to promote academic achievement in selected high school physics classes at a rural middle Tennessee high school. This study used an ex post facto , quasi-experimental research methodology. The independent variables in this study were the instructional methods of teaching. The treatment variable was Modeling Instruction and the control variable was traditional lecture instruction. The Treatment Group consisted of participants in Physical World Concepts who received Modeling Instruction. The Control Group consisted of participants in Physical Science who received traditional lecture instruction. The dependent variable was gains scores on the Force Concepts Inventory (FCI). The participants for this study were 133 students each in both the Treatment and Control Groups (n = 266), who attended a public, high school in rural middle Tennessee. The participants were administered the Force Concepts Inventory (FCI) prior to being taught the mechanics of physics. The FCI data were entered into the computer-based Statistical Package for the Social Science (SPSS). Two independent samples t-tests were conducted to answer the research questions. There was a statistically significant difference between the treatment and control groups concerning the instructional method. Modeling Instructional methods were found to be effective in increasing the academic achievement of students in high school physics. There was no statistically significant difference between FCI gains scores for gender. Gender was found to have no effect on the academic achievement of students in high school physics classes. However, even though there was not a statistically significant difference, female students' gains scores were higher than male students' gains scores when Modeling Instructional methods of teaching were used. Based on these findings, it is recommended

  19. Nutrition and education. II. Educational achievement and nutrient intake of Chilean elementary and high school graduates.

    PubMed

    Ivanovic, D; Vásquez, M; Marambio, M; Ballester, D; Zacarías, I; Aguayo, M

    1991-12-01

    The interrelationships between educational achievement (EA) and nutrient intake were investigated in 550 Chilean adolescent schoolers graduating from elementary and high school. The random sample included schoolers from both educational levels (1:1), from public and private schools (1:1), and from high, medium, and low socioeconomic status (SES) (1:1:1). Standard procedures for 24-hour dietary recall interviews were used to collect data, and adequacy of intake was assessed by the FAO/WHO Pattern. EA was measured by means of the Achievement Evaluation Program (AEP) and Academic Aptitude Test (AAT) in elementary and high school, respectively. In elementary school graduates, results showed a significant and positive correlation between EA (AEP) and energy, protein, riboflavin, ascorbic acid, calcium and vitamin A intake (Multiple r = 0.456 p less than 0.01; r2 = 0.208). The School Feeding Program beneficiaries who belonged to the low SES presented the lowest EA (AEP) together with a deficient nutrient intake, especially for energy, riboflavin, niacin, vitamin A and calcium, at the same time that they registered the lowest values for those anthropometric parameters, indicators of past nutrition, that is to say height-for-age, weight-for-age, head circumference-for-age and a higher upper-to-lower segment ratio, as compared with non-beneficiaries from the same SES and with those from the higher strata. In high-school graduates, EA (AAT) was found to be significantly and positively correlated with protein, calcium, riboflavin and iron intake (Multiple r = 0.438 p less than 0.001; r2 = 0.192). Nevertheless, these interrelationship are strongly related to SES and sex. Results showed that educational achievement (EA) is significantly and positively associated with nutrient intake, this fact being important for educational planning related to the School Feeding Program. PMID:1841532

  20. Stochastic sensitivity measure for mistuned high-performance turbines

    NASA Technical Reports Server (NTRS)

    Murthy, Durbha V.; Pierre, Christophe

    1992-01-01

    A stochastic measure of sensitivity is developed in order to predict the effects of small random blade mistuning on the dynamic aeroelastic response of turbomachinery blade assemblies. This sensitivity measure is based solely on the nominal system design (i.e., on tuned system information), which makes it extremely easy and inexpensive to calculate. The measure has the potential to become a valuable design tool that will enable designers to evaluate mistuning effects at a preliminary design stage and thus assess the need for a full mistuned rotor analysis. The predictive capability of the sensitivity measure is illustrated by examining the effects of mistuning on the aeroelastic modes of the first stage of the oxidizer turbopump in the Space Shuttle Main Engine. Results from a full analysis mistuned systems confirm that the simple stochastic sensitivity measure predicts consistently the drastic changes due to misturning and the localization of aeroelastic vibration to a few blades.