Developing Reliable Life Support for Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
A human mission to Mars will require highly reliable life support systems. Mars life support systems may recycle water and oxygen using systems similar to those on the International Space Station (ISS). However, achieving sufficient reliability is less difficult for ISS than it will be for Mars. If an ISS system has a serious failure, it is possible to provide spare parts, or directly supply water or oxygen, or if necessary bring the crew back to Earth. Life support for Mars must be designed, tested, and improved as needed to achieve high demonstrated reliability. A quantitative reliability goal should be established and used to guide development t. The designers should select reliable components and minimize interface and integration problems. In theory a system can achieve the component-limited reliability, but testing often reveal unexpected failures due to design mistakes or flawed components. Testing should extend long enough to detect any unexpected failure modes and to verify the expected reliability. Iterated redesign and retest may be required to achieve the reliability goal. If the reliability is less than required, it may be improved by providing spare components or redundant systems. The number of spares required to achieve a given reliability goal depends on the component failure rate. If the failure rate is under estimated, the number of spares will be insufficient and the system may fail. If the design is likely to have undiscovered design or component problems, it is advisable to use dissimilar redundancy, even though this multiplies the design and development cost. In the ideal case, a human tended closed system operational test should be conducted to gain confidence in operations, maintenance, and repair. The difficulty in achieving high reliability in unproven complex systems may require the use of simpler, more mature, intrinsically higher reliability systems. The limitations of budget, schedule, and technology may suggest accepting lower and less certain expected reliability. A plan to develop reliable life support is needed to achieve the best possible reliability.
Methods and Costs to Achieve Ultra Reliable Life Support
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
A published Mars mission is used to explore the methods and costs to achieve ultra reliable life support. The Mars mission and its recycling life support design are described. The life support systems were made triply redundant, implying that each individual system will have fairly good reliability. Ultra reliable life support is needed for Mars and other long, distant missions. Current systems apparently have insufficient reliability. The life cycle cost of the Mars life support system is estimated. Reliability can be increased by improving the intrinsic system reliability, adding spare parts, or by providing technically diverse redundant systems. The costs of these approaches are estimated. Adding spares is least costly but may be defeated by common cause failures. Using two technically diverse systems is effective but doubles the life cycle cost. Achieving ultra reliability is worth its high cost because the penalty for failure is very high.
High reliability and implications for nursing leaders.
Riley, William
2009-03-01
To review high reliability theory and discuss its implications for the nursing leader. A high reliability organization (HRO) is considered that which has measurable near perfect performance for quality and safety. The author has reviewed the literature, discussed research findings that contribute to improving reliability in health care organizations, and makes five recommendations for how nursing leaders can create high reliability organizations. Health care is not a safe industry and unintended patient harm occurs at epidemic levels. Health care can learn from high reliability theory and practice developed in other high-risk industries. Viewed by HRO standards, unintended patient injury in health care is excessively high and quality is distressingly low. HRO theory and practice can be successfully applied in health care using advanced interdisciplinary teamwork training and deliberate process design techniques. Nursing has a primary leadership function for ensuring patient safety and achieving high quality in health care organizations. Learning HRO theory and methods for achieving high reliability is a foremost opportunity for nursing leaders.
Achieving High Reliability with People, Processes, and Technology.
Saunders, Candice L; Brennan, John A
2017-01-01
High reliability as a corporate value in healthcare can be achieved by meeting the "Quadruple Aim" of improving population health, reducing per capita costs, enhancing the patient experience, and improving provider wellness. This drive starts with the board of trustees, CEO, and other senior leaders who ingrain high reliability throughout the organization. At WellStar Health System, the board developed an ambitious goal to become a top-decile health system in safety and quality metrics. To achieve this goal, WellStar has embarked on a journey toward high reliability and has committed to Lean management practices consistent with the Institute for Healthcare Improvement's definition of a high-reliability organization (HRO): one that is committed to the prevention of failure, early identification and mitigation of failure, and redesign of processes based on identifiable failures. In the end, a successful HRO can provide safe, effective, patient- and family-centered, timely, efficient, and equitable care through a convergence of people, processes, and technology.
Reliability Considerations for the Operation of Large Accelerator User Facilities
Willeke, F. J.
2016-01-29
The lecture provides an overview of considerations relevant for achieving highly reliable operation of accelerator based user facilities. The article starts with an overview of statistical reliability formalism which is followed by high reliability design considerations with examples. Finally, the article closes with operational aspects of high reliability such as preventive maintenance and spares inventory.
Reliability achievement in high technology space systems
NASA Technical Reports Server (NTRS)
Lindstrom, D. L.
1981-01-01
The production of failure-free hardware is discussed. The elements required to achieve such hardware are: technical expertise to design, analyze, and fully understand the design; use of high reliability parts and materials control in the manufacturing process; and testing to understand the system and weed out defects. The durability of the Hughes family of satellites is highlighted.
Fujii, Mami N.; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei
2015-01-01
The use of indium–gallium–zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic–inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic–inorganic hybrid devices. PMID:26677773
Fujii, Mami N; Ishikawa, Yasuaki; Miwa, Kazumoto; Okada, Hiromi; Uraoka, Yukiharu; Ono, Shimpei
2015-12-18
The use of indium-gallium-zinc oxide (IGZO) has paved the way for high-resolution uniform displays or integrated circuits with transparent and flexible devices. However, achieving highly reliable devices that use IGZO for low-temperature processes remains a technological challenge. We propose the use of IGZO thin-film transistors (TFTs) with an ionic-liquid gate dielectric in order to achieve high-density carrier-accumulated IGZO TFTs with high reliability, and we discuss a distinctive mechanism for the degradation of this organic-inorganic hybrid device under long-term electrical stress. Our results demonstrated that an ionic liquid or gel gate dielectric provides highly reliable and low-voltage operation with IGZO TFTs. Furthermore, high-density carrier accumulation helps improve the TFT characteristics and reliability, and it is highly relevant to the electronic phase control of oxide materials and the degradation mechanism for organic-inorganic hybrid devices.
Usefulness of the Patient Health Questionnaire-9 for Korean medical students.
Yoon, Seoyoung; Lee, Yunhwan; Han, Changsu; Pae, Chi-Un; Yoon, Ho-Kyoung; Patkar, Ashwin A; Steffens, David C; Kim, Yong-Ku
2014-12-01
Depression may be highly prevalent among medical students, lowering their functioning and quality of life. Using appropriate extant depression scales to screen for depression and determining factors associated with depression can be helpful in managing it. This study examines the validity and reliability of the Patient Health Questionnaire-9 (PHQ-9) for medical students and the relationship between their scores and sociodemographic variables. This study surveyed 174 medical students using demographic questionnaires, the PHQ-9, the Beck Depression Inventory (BDI), the Patient Heath Questionnaire-15 (PHQ-15), the Beck Anxiety Inventory (BAI), and the Perceived Stress Scale (PSS). It calculated the Cronbach's α for internal consistency and Pearson's correlation coefficients for test-retest reliability and convergent validity of the PHQ-9. In order to examine the relationship between depression and demographic variables, this study performed independent t tests, one-way analysis of variance, chi-square, and binary logistic regressions. The PHQ-9 was reliable (Cronbach's α = 0.837, test-retest reliability, r = 0.650) and valid (r = 0.509-0.807) when employed with medical students. Total scores on the PHQ-9 were significantly higher among low-perceived academic achievers than among high-perceived academic achievers (p < 0.01). Depression was more prevalent in poor-perceived academic achievers than in high-perceived academic achievers. Similarly, poor-perceived academic achievers were at greater risk of depression than were high-perceived academic achievers (odds ratio [95 % confidence interval] 3.686 [1.092-12.439], p < 0.05). The PHQ-9 has satisfactory reliability and validity in medical students in South Korea. Depression is related to poor-perceived academic achievement when measured with the PHQ-9. Early screening for depression with the PHQ-9 in medical students and providing prompt management to high scorers may not only be beneficial to students' mental health but also improve their academic performance.
Bandwidth efficient coding for satellite communications
NASA Technical Reports Server (NTRS)
Lin, Shu; Costello, Daniel J., Jr.; Miller, Warner H.; Morakis, James C.; Poland, William B., Jr.
1992-01-01
An error control coding scheme was devised to achieve large coding gain and high reliability by using coded modulation with reduced decoding complexity. To achieve a 3 to 5 dB coding gain and moderate reliability, the decoding complexity is quite modest. In fact, to achieve a 3 dB coding gain, the decoding complexity is quite simple, no matter whether trellis coded modulation or block coded modulation is used. However, to achieve coding gains exceeding 5 dB, the decoding complexity increases drastically, and the implementation of the decoder becomes very expensive and unpractical. The use is proposed of coded modulation in conjunction with concatenated (or cascaded) coding. A good short bandwidth efficient modulation code is used as the inner code and relatively powerful Reed-Solomon code is used as the outer code. With properly chosen inner and outer codes, a concatenated coded modulation scheme not only can achieve large coding gains and high reliability with good bandwidth efficiency but also can be practically implemented. This combination of coded modulation and concatenated coding really offers a way of achieving the best of three worlds, reliability and coding gain, bandwidth efficiency, and decoding complexity.
Technology developments toward 30-year-life of photovoltaic modules
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.
1984-01-01
As part of the United States National Photovoltaics Program, the Jet Propulsion Laboratory's Flat-Plate Solar Array Project (FSA) has maintained a comprehensive reliability and engineering sciences activity addressed toward understanding the reliability attributes of terrestrial flat-plate photovoltaic arrays and to deriving analysis and design tools necessary to achieve module designs with a 30-year useful life. The considerable progress to date stemming from the ongoing reliability research is discussed, and the major areas requiring continued research are highlighted. The result is an overview of the total array reliability problem and of available means of achieving high reliability at minimum cost.
Solid Insulated Switchgear and Investigation of its Mechanical and Electrical Reliability
NASA Astrophysics Data System (ADS)
Sato, Junichi; Kinoshita, Susumu; Sakaguchi, Osamu; Miyagawa, Masaru; Shimizu, Toshio; Homma, Mitsutaka
SF6 gas is applied widely to medium voltage switchgear because of its high insulation reliability and down-sizing ability. However, SF6 gas was placed on the list of greenhouse gases under the Kyoto Protocol in 1997. Since then, the investigation and development concerning SF6-free or less has carried out activity. Therefore, we paid attention to the solid material which has higher dielectric strength than SF6, and we have newly developed solid insulated switchgear (SIS) achieved by molding all main circuit. A new epoxy casting material is applied, which contains a great deal of spherical silica and a small amount of rubber particles. This new material has the high mechanical strength, high thermal resistance, high toughness, and also high dielectric strength because of directly molding the vacuum bottle, down-sizing and reliability. This paper describes about the technology of a new epoxy casting material which achieves the SIS. In addition, the mechanical and electrical reliability test of SIS applied a new epoxy resin are carried out, and effectiveness of the development material and the mechanical and electrical reliability of SIS are verified.
High-reliability release mechanism
NASA Technical Reports Server (NTRS)
Paradise, J. J.
1971-01-01
Release mechanism employing simple clevis fitting in combination with two pin-pullers achieves high reliability degree through active mechanical redundancy. Mechanism releases solar arrays. It is simple and inexpensive and performs effectively. It adapts to other release-system applications with variety of pin-puller devices.
An Investigation of the Generalizability of Medical School Grades.
Kreiter, Clarence D; Ferguson, Kristi J
2016-01-01
Construct/Background: Medical school grades are currently unstandardized, and their level of reliability is unknown. This means their usefulness for reporting on student achievement is also not well documented. This study investigates grade reliability within 1 medical school. Generalizability analyses are conducted on grades awarded. Grades from didactic and clerkship-based courses were treated as 2 levels of a fixed facet within a univariate mixed model. Grades from within the 2 levels (didactic and clerkship) were also entered in a multivariate generalizability study. Grades from didactic courses were shown to produce a highly reliable mean score (G = .79) when averaged over as few as 5 courses. Although the universe score correlation between didactic and clerkship courses was high (r = .80), the clerkship courses required almost twice as many grades to reach a comparable level of reliability. When grades were converted to a Pass/Fail metric, almost all information contained in the grades was lost. Although it has been suggested that the imprecision of medical school grades precludes their use as a reliable indicator of student achievement, these results suggest otherwise. While it is true that a Pass/Fail system of grading provides very little information about a student's level of performance, a multi-tiered grading system was shown to be a highly reliable indicator of student achievement within the medical school. Although grades awarded during the first 2 didactic years appear to be more reliable than clerkship grades, both yield useful information about student performance within the medical college.
High-Reliability Health Care: Getting There from Here
Chassin, Mark R; Loeb, Jerod M
2013-01-01
Context Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer “project fatigue” because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. Methods We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals’ readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. Findings We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Conclusions Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. PMID:24028696
High-reliability health care: getting there from here.
Chassin, Mark R; Loeb, Jerod M
2013-09-01
Despite serious and widespread efforts to improve the quality of health care, many patients still suffer preventable harm every day. Hospitals find improvement difficult to sustain, and they suffer "project fatigue" because so many problems need attention. No hospitals or health systems have achieved consistent excellence throughout their institutions. High-reliability science is the study of organizations in industries like commercial aviation and nuclear power that operate under hazardous conditions while maintaining safety levels that are far better than those of health care. Adapting and applying the lessons of this science to health care offer the promise of enabling hospitals to reach levels of quality and safety that are comparable to those of the best high-reliability organizations. We combined the Joint Commission's knowledge of health care organizations with knowledge from the published literature and from experts in high-reliability industries and leading safety scholars outside health care. We developed a conceptual and practical framework for assessing hospitals' readiness for and progress toward high reliability. By iterative testing with hospital leaders, we refined the framework and, for each of its fourteen components, defined stages of maturity through which we believe hospitals must pass to reach high reliability. We discovered that the ways that high-reliability organizations generate and maintain high levels of safety cannot be directly applied to today's hospitals. We defined a series of incremental changes that hospitals should undertake to progress toward high reliability. These changes involve the leadership's commitment to achieving zero patient harm, a fully functional culture of safety throughout the organization, and the widespread deployment of highly effective process improvement tools. Hospitals can make substantial progress toward high reliability by undertaking several specific organizational change initiatives. Further research and practical experience will be necessary to determine the validity and effectiveness of this framework for high-reliability health care. © 2013 The Authors. The Milbank Quarterly published by Wiley Periodicals Inc. on behalf of Milbank Memorial Fund.
Achieving Reliable Communication in Dynamic Emergency Responses
Chipara, Octav; Plymoth, Anders N.; Liu, Fang; Huang, Ricky; Evans, Brian; Johansson, Per; Rao, Ramesh; Griswold, William G.
2011-01-01
Emergency responses require the coordination of first responders to assess the condition of victims, stabilize their condition, and transport them to hospitals based on the severity of their injuries. WIISARD is a system designed to facilitate the collection of medical information and its reliable dissemination during emergency responses. A key challenge in WIISARD is to deliver data with high reliability as first responders move and operate in a dynamic radio environment fraught with frequent network disconnections. The initial WIISARD system employed a client-server architecture and an ad-hoc routing protocol was used to exchange data. The system had low reliability when deployed during emergency drills. In this paper, we identify the underlying causes of unreliability and propose a novel peer-to-peer architecture that in combination with a gossip-based communication protocol achieves high reliability. Empirical studies show that compared to the initial WIISARD system, the redesigned system improves reliability by as much as 37% while reducing the number of transmitted packets by 23%. PMID:22195075
Space Shuttle Reusable Solid Rocket Motor
NASA Technical Reports Server (NTRS)
Moore, Dennis; Phelps, Jack; Perkins, Fred
2010-01-01
RSRM is a highly reliable human-rated Solid Rocket Motor: a) Largest diameter SRM to achieve flight status; b) Only human-rated SRM. RSRM reliability achieved by: a)Applying special attention to Process Control, Testing, and Postflight; b) Communicating often; c) Identifying and addressing issues in a disciplined approach; d) Identifying and fully dispositioning "out-of-family" conditions; e) Addressing minority opinions; and f) Learning our lessons.
Sticca, Fabio; Goetz, Thomas; Bieg, Madeleine; Hall, Nathan C; Eberle, Franz; Haag, Ludwig
2017-01-01
The present longitudinal study examined the reliability of self-reported academic grades across three phases in four subject domains for a sample of 916 high-school students. Self-reported grades were found to be highly positively correlated with actual grades in all academic subjects and across grades 9 to 11 underscoring the reliability of self-reported grades as an achievement indicator. Reliability of self-reported grades was found to differ across subject areas (e.g., mathematics self-reports more reliable than language studies), with a slight yet consistent tendency to over-report achievement levels also observed across grade levels and academic subjects. Overall, the absolute value of over- and underreporting was low and these patterns were not found to differ between mathematics and verbal subjects. In sum, study findings demonstrate the consistent predictive utility of students' self-reported achievement across grade levels and subject areas with the observed tendency to over-report academic grades and slight differences between domains nonetheless warranting consideration in future education research.
Goetz, Thomas
2017-01-01
The present longitudinal study examined the reliability of self-reported academic grades across three phases in four subject domains for a sample of 916 high-school students. Self-reported grades were found to be highly positively correlated with actual grades in all academic subjects and across grades 9 to 11 underscoring the reliability of self-reported grades as an achievement indicator. Reliability of self-reported grades was found to differ across subject areas (e.g., mathematics self-reports more reliable than language studies), with a slight yet consistent tendency to over-report achievement levels also observed across grade levels and academic subjects. Overall, the absolute value of over- and underreporting was low and these patterns were not found to differ between mathematics and verbal subjects. In sum, study findings demonstrate the consistent predictive utility of students’ self-reported achievement across grade levels and subject areas with the observed tendency to over-report academic grades and slight differences between domains nonetheless warranting consideration in future education research. PMID:29112979
Davenport, Paul B; Carter, Kimberly F; Echternach, Jeffrey M; Tuck, Christopher R
2018-02-01
High-reliability organizations (HROs) demonstrate unique and consistent characteristics, including operational sensitivity and control, situational awareness, hyperacute use of technology and data, and actionable process transformation. System complexity and reliance on information-based processes challenge healthcare organizations to replicate HRO processes. This article describes a healthcare organization's 3-year journey to achieve key HRO features to deliver high-quality, patient-centric care via an operations center powered by the principles of high-reliability data and software to impact patient throughput and flow.
Ultra Reliable Closed Loop Life Support for Long Space Missions
NASA Technical Reports Server (NTRS)
Jones, Harry W.; Ewert, Michael K.
2010-01-01
Spacecraft human life support systems can achieve ultra reliability by providing sufficient spares to replace all failed components. The additional mass of spares for ultra reliability is approximately equal to the original system mass, provided that the original system reliability is not too low. Acceptable reliability can be achieved for the Space Shuttle and Space Station by preventive maintenance and by replacing failed units. However, on-demand maintenance and repair requires a logistics supply chain in place to provide the needed spares. In contrast, a Mars or other long space mission must take along all the needed spares, since resupply is not possible. Long missions must achieve ultra reliability, a very low failure rate per hour, since they will take years rather than weeks and cannot be cut short if a failure occurs. Also, distant missions have a much higher mass launch cost per kilogram than near-Earth missions. Achieving ultra reliable spacecraft life support systems with acceptable mass will require a well-planned and extensive development effort. Analysis must determine the reliability requirement and allocate it to subsystems and components. Ultra reliability requires reducing the intrinsic failure causes, providing spares to replace failed components and having "graceful" failure modes. Technologies, components, and materials must be selected and designed for high reliability. Long duration testing is needed to confirm very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The system must be designed, developed, integrated, and tested with system reliability in mind. Maintenance and reparability of failed units must not add to the probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass should start soon since it must be a long term effort.
Reliability and Failure in NASA Missions: Blunders, Normal Accidents, High Reliability, Bad Luck
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2015-01-01
NASA emphasizes crew safety and system reliability but several unfortunate failures have occurred. The Apollo 1 fire was mistakenly unanticipated. After that tragedy, the Apollo program gave much more attention to safety. The Challenger accident revealed that NASA had neglected safety and that management underestimated the high risk of shuttle. Probabilistic Risk Assessment was adopted to provide more accurate failure probabilities for shuttle and other missions. NASA's "faster, better, cheaper" initiative and government procurement reform led to deliberately dismantling traditional reliability engineering. The Columbia tragedy and Mars mission failures followed. Failures can be attributed to blunders, normal accidents, or bad luck. Achieving high reliability is difficult but possible.
Creating Highly Reliable Accountable Care Organizations.
Vogus, Timothy J; Singer, Sara J
2016-12-01
Accountable Care Organizations' (ACOs) pursuit of the triple aim of higher quality, lower cost, and improved population health has met with mixed results. To improve the design and implementation of ACOs we look to organizations that manage similarly complex, dynamic, and tightly coupled conditions while sustaining exceptional performance known as high-reliability organizations. We describe the key processes through which organizations achieve reliability, the leadership and organizational practices that enable it, and the role that professionals can play when charged with enacting it. Specifically, we present concrete practices and processes from health care organizations pursuing high-reliability and from early ACOs to illustrate how the triple aim may be met by cultivating mindful organizing, practicing reliability-enhancing leadership, and identifying and supporting reliability professionals. We conclude by proposing a set of research questions to advance the study of ACOs and high-reliability research. © The Author(s) 2016.
Developing Ultra Reliable Life Support for the Moon and Mars
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2009-01-01
Recycling life support systems can achieve ultra reliability by using spares to replace failed components. The added mass for spares is approximately equal to the original system mass, provided the original system reliability is not very low. Acceptable reliability can be achieved for the space shuttle and space station by preventive maintenance and by replacing failed units, However, this maintenance and repair depends on a logistics supply chain that provides the needed spares. The Mars mission must take all the needed spares at launch. The Mars mission also must achieve ultra reliability, a very low failure rate per hour, since it requires years rather than weeks and cannot be cut short if a failure occurs. Also, the Mars mission has a much higher mass launch cost per kilogram than shuttle or station. Achieving ultra reliable space life support with acceptable mass will require a well-planned and extensive development effort. Analysis must define the reliability requirement and allocate it to subsystems and components. Technologies, components, and materials must be designed and selected for high reliability. Extensive testing is needed to ascertain very low failure rates. Systems design should segregate the failure causes in the smallest, most easily replaceable parts. The systems must be designed, produced, integrated, and tested without impairing system reliability. Maintenance and failed unit replacement should not introduce any additional probability of failure. The overall system must be tested sufficiently to identify any design errors. A program to develop ultra reliable space life support systems with acceptable mass must start soon if it is to produce timely results for the moon and Mars.
ERIC Educational Resources Information Center
Davis, Andrew
2015-01-01
PISA claims that it can extend its reach from its current core subjects of Reading, Science, Maths and problem-solving. Yet given the requirement for high levels of reliability for PISA, especially in the light of its current high stakes character, proposed widening of its subject coverage cannot embrace some important aspects of the social and…
Design and Analysis of a Flexible, Reliable Deep Space Life Support System
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2012-01-01
This report describes a flexible, reliable, deep space life support system design approach that uses either storage or recycling or both together. The design goal is to provide the needed life support performance with the required ultra reliability for the minimum Equivalent System Mass (ESM). Recycling life support systems used with multiple redundancy can have sufficient reliability for deep space missions but they usually do not save mass compared to mixed storage and recycling systems. The best deep space life support system design uses water recycling with sufficient water storage to prevent loss of crew if recycling fails. Since the amount of water needed for crew survival is a small part of the total water requirement, the required amount of stored water is significantly less than the total to be consumed. Water recycling with water, oxygen, and carbon dioxide removal material storage can achieve the high reliability of full storage systems with only half the mass of full storage and with less mass than the highly redundant recycling systems needed to achieve acceptable reliability. Improved recycling systems with lower mass and higher reliability could perform better than systems using storage.
Teamwork as an Essential Component of High-Reliability Organizations
Baker, David P; Day, Rachel; Salas, Eduardo
2006-01-01
Organizations are increasingly becoming dynamic and unstable. This evolution has given rise to greater reliance on teams and increased complexity in terms of team composition, skills required, and degree of risk involved. High-reliability organizations (HROs) are those that exist in such hazardous environments where the consequences of errors are high, but the occurrence of error is extremely low. In this article, we argue that teamwork is an essential component of achieving high reliability particularly in health care organizations. We describe the fundamental characteristics of teams, review strategies in team training, demonstrate the criticality of teamwork in HROs and finally, identify specific challenges the health care community must address to improve teamwork and enhance reliability. PMID:16898980
NASA Technical Reports Server (NTRS)
Feldstein, J. F.
1977-01-01
Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.
Improving patient safety: patient-focused, high-reliability team training.
McKeon, Leslie M; Cunningham, Patricia D; Oswaks, Jill S Detty
2009-01-01
Healthcare systems are recognizing "human factor" flaws that result in adverse outcomes. Nurses work around system failures, although increasing healthcare complexity makes this harder to do without risk of error. Aviation and military organizations achieve ultrasafe outcomes through high-reliability practice. We describe how reliability principles were used to teach nurses to improve patient safety at the front line of care. Outcomes include safety-oriented, teamwork communication competency; reflections on safety culture and clinical leadership are discussed.
Survey of Software Assurance Techniques for Highly Reliable Systems
NASA Technical Reports Server (NTRS)
Nelson, Stacy
2004-01-01
This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L.
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale’s reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement. PMID:28701964
Leon, Jaime; Medina-Garrido, Elena; Núñez, Juan L
2017-01-01
Math achievement and engagement declines in secondary education; therefore, educators are faced with the challenge of engaging students to avoid school failure. Within self-determination theory, we address the need to assess comprehensively student perceptions of teaching quality that predict engagement and achievement. In study one we tested, in a sample of 548 high school students, a preliminary version of a scale to assess nine factors: teaching for relevance, acknowledge negative feelings, participation encouragement, controlling language, optimal challenge, focus on the process, class structure, positive feedback, and caring. In the second study, we analyzed the scale's reliability and validity in a sample of 1555 high school students. The scale showed evidence of reliability, and with regard to criterion validity, at the classroom level, teaching quality was a predictor of behavioral engagement, and higher grades were observed in classes where students, as a whole, displayed more behavioral engagement. At the within level, behavioral engagement was associated with achievement. We not only provide a reliable and valid method to assess teaching quality, but also a method to design interventions, these could be designed based on the scale items to encourage students to persist and display more engagement on school duties, which in turn bolsters student achievement.
High-reliability gas-turbine combined-cycle development program: Phase II. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. This volume presents information of the reliability, availability, and maintainability (RAM) analysis of a representative plant and the preliminary design of the gas turbine, the gas turbine ancillaries, and the balance of plant including themore » steam turbine generator. To achieve the program goals, a gas turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000 hours. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and mandual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-hour EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricity compared to present market offerings.« less
NASA Technical Reports Server (NTRS)
Gillespie, Amanda M.
2012-01-01
The future of Space Exploration includes missions to the moon, asteroids, Mars, and beyond. To get there, the mission concept is to launch multiple launch vehicles months, even years apart. In order to achieve this, launch vehicles, payloads (satellites and crew capsules), and ground systems must be highly reliable and/or available, to include maintenance concepts and procedures in the event of a launch scrub. In order to achieve this high probability of mission success, Ground Systems Development and Operations (GSDO) has allocated Reliability, Maintainability, and Availability (RMA) requirements to all hardware and software required for both launch operations and, in the event of a launch scrub, required to support a repair of the ground systems, launch vehicle, or payload. This is done concurrently with the design process (30/60/90 reviews).
Atmospheric Models for Over-Ocean Propagation Loss
2015-05-15
Atmospheric Models For Over-Ocean Propagation Loss Bruce McGuffin1 MIT Lincoln Laboratory Introduction Air -to-surface radio links differ from...from radiosonde profiles collected along the Atlantic coast of the United States, in order to accurately estimate high-reliability SHF/EHF air -to...predict required link performance to achieve high reliability at different locations and times of year. Data Acquisition Radiosonde balloons are
Modeling of a bubble-memory organization with self-checking translators to achieve high reliability.
NASA Technical Reports Server (NTRS)
Bouricius, W. G.; Carter, W. C.; Hsieh, E. P.; Wadia, A. B.; Jessep, D. C., Jr.
1973-01-01
Study of the design and modeling of a highly reliable bubble-memory system that has the capabilities of: (1) correcting a single 16-adjacent bit-group error resulting from failures in a single basic storage module (BSM), and (2) detecting with a probability greater than 0.99 any double errors resulting from failures in BSM's. The results of the study justify the design philosophy adopted of employing memory data encoding and a translator to correct single group errors and detect double group errors to enhance the overall system reliability.
A pulse-compression-ring circuit for high-efficiency electric propulsion.
Owens, Thomas L
2008-03-01
A highly efficient, highly reliable pulsed-power system has been developed for use in high power, repetitively pulsed inductive plasma thrusters. The pulsed inductive thruster ejects plasma propellant at a high velocity using a Lorentz force developed through inductive coupling to the plasma. Having greatly increased propellant-utilization efficiency compared to chemical rockets, this type of electric propulsion system may one day propel spacecraft on long-duration deep-space missions. High system reliability and electrical efficiency are extremely important for these extended missions. In the prototype pulsed-power system described here, exceptional reliability is achieved using a pulse-compression circuit driven by both active solid-state switching and passive magnetic switching. High efficiency is achieved using a novel ring architecture that recovers unused energy in a pulse-compression system with minimal circuit loss after each impulse. As an added benefit, voltage reversal is eliminated in the ring topology, resulting in long lifetimes for energy-storage capacitors. System tests were performed using an adjustable inductive load at a voltage level of 3.3 kV, a peak current of 20 kA, and a current switching rate of 15 kA/micros.
High-reliability gas-turbine combined-cycle development program: Phase II, Volume 3. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hecht, K.G.; Sanderson, R.A.; Smith, M.J.
This three-volume report presents the results of Phase II of the multiphase EPRI-sponsored High-Reliability Gas Turbine Combined-Cycle Development Program whose goal is to achieve a highly reliable gas turbine combined-cycle power plant, available by the mid-1980s, which would be an economically attractive baseload generation alternative for the electric utility industry. The Phase II program objective was to prepare the preliminary design of this power plant. The power plant was addressed in three areas: (1) the gas turbine, (2) the gas turbine ancillaries, and (3) the balance of plant including the steam turbine generator. To achieve the program goals, a gasmore » turbine was incorporated which combined proven reliability characteristics with improved performance features. This gas turbine, designated the V84.3, is the result of a cooperative effort between Kraftwerk Union AG and United Technologies Corporation. Gas turbines of similar design operating in Europe under baseload conditions have demonstrated mean time between failures in excess of 40,000. The reliability characteristics of the gas turbine ancillaries and balance-of-plant equipment were improved through system simplification and component redundancy and by selection of component with inherent high reliability. A digital control system was included with logic, communications, sensor redundancy, and manual backup. An independent condition monitoring and diagnostic system was also included. Program results provide the preliminary design of a gas turbine combined-cycle baseload power plant. This power plant has a predicted mean time between failure of nearly twice the 3000-h EPRI goal. The cost of added reliability features is offset by improved performance, which results in a comparable specific cost and an 8% lower cost of electricty compared to present market offerings.« less
ERIC Educational Resources Information Center
Guan, Jianmin; McBride, Ron; Xiang, Ping
2007-01-01
Although empirical research in academic areas provides support for both a 3-factor as well as a 4-factor achievement goal model, both models were proposed and tested with a collegiate sample. Little is known about the generalizability of either model with high school level samples. This study was designed to examine whether the 3-factor model…
NASA Astrophysics Data System (ADS)
Miyaji, Kousuke; Yajima, Ryoji; Hatanaka, Teruyoshi; Takahashi, Mitsue; Sakai, Shigeki; Takeuchi, Ken
Initialize and weak-program erasing scheme is proposed to achieve high-performance and high-reliability Ferroelectric (Fe-) NAND flash solid-state drive (SSD). Bit-by-bit erase VTH control is achieved by the proposed erasing scheme and history effects in Fe-NAND is also suppressed. History effects change the future erase VTH shift characteristics by the past program voltage. The proposed erasing scheme decreases VTH shift variation due to history effects from ±40% to ±2% and the erase VTH distribution width is reduced from over 0.4V to 0.045V. As a result, the read and VPASS disturbance decrease by 42% and 37%, respectively. The proposed erasing scheme is immune to VTH variations and voltage stress. The proposed erasing scheme also suppresses the power and bandwidth degradation of SSD.
Preliminary study of the reliability of imaging charge coupled devices
NASA Technical Reports Server (NTRS)
Beall, J. R.; Borenstein, M. D.; Homan, R. A.; Johnson, D. L.; Wilson, D. D.; Young, V. F.
1978-01-01
Imaging CCDs are capable of low light level response and high signal-to-noise ratios. In space applications they offer the user the ability to achieve extremely high resolution imaging with minimum circuitry in the photo sensor array. This work relates the CCD121H Fairchild device to the fundamentals of CCDs and the representative technologies. Several failure modes are described, construction is analyzed and test results are reported. In addition, the relationship of the device reliability to packaging principles is analyzed and test data presented. Finally, a test program is defined for more general reliability evaluation of CCDs.
Myer, Gregory D; Bates, Nathaniel A; DiCesare, Christopher A; Barber Foss, Kim D; Thomas, Staci M; Wordeman, Samuel C; Sugimoto, Dai; Roewer, Benjamin D; Medina McKeon, Jennifer M; Di Stasi, Stephanie L; Noehren, Brian W; McNally, Michael; Ford, Kevin R; Kiefer, Adam W; Hewett, Timothy E
2015-05-01
Due to the limitations of single-center studies in achieving appropriate sampling with relatively rare disorders, multicenter collaborations have been proposed to achieve desired sampling levels. However, documented reliability of biomechanical data is necessary for multicenter injury-prevention studies and is currently unavailable. To measure the reliability of 3-dimensional (3D) biomechanical waveforms from kinetic and kinematic variables during a single-leg landing (SLL) performed at 3 separate testing facilities. Multicenter reliability study. 3 laboratories. 25 female junior varsity and varsity high school volleyball players who visited each facility over a 1-mo period. Subjects were instrumented with 43 reflective markers to record 3D motion as they performed SLLs. During the SLL the athlete balanced on 1 leg, dropped down off of a 31-cm-high box, and landed on the same leg. Kinematic and kinetic data from both legs were processed from 2 trials across the 3 laboratories. Coefficients of multiple correlations (CMC) were used to statistically compare each joint angle and moment waveform for the first 500 ms of landing. Average CMC for lower-extremity sagittal-plane motion was excellent between laboratories (hip .98, knee .95, ankle .99). Average CMC for lower-extremity frontal-plane motion was also excellent between laboratories (hip .98, knee .80, ankle .93). Kinetic waveforms were repeatable in each plane of rotation (3-center mean CMC ≥.71), while knee sagittal-plane moments were the most consistent measure across sites (3-center mean CMC ≥.94). CMC waveform comparisons were similar relative to the joint measured to previously published reports of between-sessions reliability of sagittal- and frontal-plane biomechanics performed at a single institution. Continued research is needed to further standardize technology and methods to help ensure that highly reliable results can be achieved with multicenter biomechanical screening models.
Training and quality assurance with the Structured Clinical Interview for DSM-IV (SCID-I/P).
Ventura, J; Liberman, R P; Green, M F; Shaner, A; Mintz, J
1998-06-15
Accuracy in psychiatric diagnosis is critical for evaluating the suitability of the subjects for entry into research protocols and for establishing comparability of findings across study sites. However, training programs in the use of diagnostic instruments for research projects are not well systematized. Furthermore, little information has been published on the maintenance of interrater reliability of diagnostic assessments. At the UCLA Research Center for Major Mental Illnesses, a Training and Quality Assurance Program for SCID interviewers was used to evaluate interrater reliability and diagnostic accuracy. Although clinically experienced interviewers achieved better interrater reliability and overall diagnostic accuracy than neophyte interviewers, both groups were able to achieve and maintain high levels of interrater reliability, diagnostic accuracy, and interviewer skill. At the first quality assurance check after training, there were no significant differences between experienced and neophyte interviewers in interrater reliability or diagnostic accuracy. Standardization of training and quality assurance procedures within and across research projects may make research findings from study sites more comparable.
Sullivan, Jennifer L; Rivard, Peter E; Shin, Marlena H; Rosen, Amy K
2016-09-01
The lack of a tool for categorizing and differentiating hospitals according to their high reliability organization (HRO)-related characteristics has hindered progress toward implementing and sustaining evidence-based HRO practices. Hospitals would benefit both from an understanding of the organizational characteristics that support HRO practices and from knowledge about the steps necessary to achieve HRO status to reduce the risk of harm and improve outcomes. The High Reliability Health Care Maturity (HRHCM) model, a model for health care organizations' achievement of high reliability with zero patient harm, incorporates three major domains critical for promoting HROs-Leadership, Safety Culture, and Robust Process Improvement ®. A study was conducted to examine the content validity of the HRHCM model and evaluate whether it can differentiate hospitals' maturity levels for each of the model's components. Staff perceptions of patient safety at six US Department of Veterans Affairs (VA) hospitals were examined to determine whether all 14 HRHCM components were present and to characterize each hospital's level of organizational maturity. Twelve of the 14 components from the HRHCM model were detected; two additional characteristics emerged that are present in the HRO literature but not represented in the model-teamwork culture and system-focused tools for learning and improvement. Each hospital's level of organizational maturity could be characterized for 9 of the 14 components. The findings suggest the HRHCM model has good content validity and that there is differentiation between hospitals on model components. Additional research is needed to understand how these components can be used to build the infrastructure necessary for reaching high reliability.
Developing Achievement Test: A Research for Assessment of 5th Grade Biology Subject
ERIC Educational Resources Information Center
Sener, Nilay; Tas, Erol
2017-01-01
The purpose of this study is to prepare a multiple-choice achievement test with high reliability and validity for the "Let's Solve the Puzzle of Our Body" unit. For this purpose, a multiple choice achievement test consisting of 46 items was applied to 178 fifth grade students in total. As a result of the test and material analysis…
ERIC Educational Resources Information Center
Haider, Zubair; Latif, Farah; Akhtar, Samina; Mushtaq, Maria
2012-01-01
Validity, reliability and item analysis are critical to the process of evaluating the quality of an educational measurement. The present study evaluates the quality of an assessment constructed to measure elementary school student's achievement in English. In this study, the survey model of descriptive research was used as a research method.…
A Vision for Spaceflight Reliability: NASA's Objectives Based Strategy
NASA Technical Reports Server (NTRS)
Groen, Frank; Evans, John; Hall, Tony
2015-01-01
In defining the direction for a new Reliability and Maintainability standard, OSMA has extracted the essential objectives that our programs need, to undertake a reliable mission. These objectives have been structured to lead mission planning through construction of an objective hierarchy, which defines the critical approaches for achieving high reliability and maintainability (R M). Creating a hierarchy, as a basis for assurance implementation, is a proven approach; yet, it holds the opportunity to enable new directions, as NASA moves forward in tackling the challenges of space exploration.
Social influences on adaptive criterion learning.
Cassidy, Brittany S; Dubé, Chad; Gutchess, Angela H
2015-07-01
People adaptively shift decision criteria when given biased feedback encouraging specific types of errors. Given that work on this topic has been conducted in nonsocial contexts, we extended the literature by examining adaptive criterion learning in both social and nonsocial contexts. Specifically, we compared potential differences in criterion shifting given performance feedback from social sources varying in reliability and from a nonsocial source. Participants became lax when given false positive feedback for false alarms, and became conservative when given false positive feedback for misses, replicating prior work. In terms of a social influence on adaptive criterion learning, people became more lax in response style over time if feedback was provided by a nonsocial source or by a social source meant to be perceived as unreliable and low-achieving. In contrast, people adopted a more conservative response style over time if performance feedback came from a high-achieving and reliable source. Awareness that a reliable and high-achieving person had not provided their feedback reduced the tendency to become more conservative, relative to those unaware of the source manipulation. Because teaching and learning often occur in a social context, these findings may have important implications for many scenarios in which people fine-tune their behaviors, given cues from others.
The process group approach to reliable distributed computing
NASA Technical Reports Server (NTRS)
Birman, Kenneth P.
1992-01-01
The difficulty of developing reliable distribution software is an impediment to applying distributed computing technology in many settings. Experience with the ISIS system suggests that a structured approach based on virtually synchronous process groups yields systems that are substantially easier to develop, exploit sophisticated forms of cooperative computation, and achieve high reliability. Six years of research on ISIS, describing the model, its implementation challenges, and the types of applications to which ISIS has been applied are reviewed.
Huang, Min; Liu, Zhaoqing; Qiao, Liyan
2014-10-10
While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it's critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB) pages which are more reliable than least significant bit (LSB) pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme.
Huang, Min; Liu, Zhaoqing; Qiao, Liyan
2014-01-01
While the NAND flash memory is widely used as the storage medium in modern sensor systems, the aggressive shrinking of process geometry and an increase in the number of bits stored in each memory cell will inevitably degrade the reliability of NAND flash memory. In particular, it's critical to enhance metadata reliability, which occupies only a small portion of the storage space, but maintains the critical information of the file system and the address translations of the storage system. Metadata damage will cause the system to crash or a large amount of data to be lost. This paper presents Asymmetric Programming, a highly reliable metadata allocation strategy for MLC NAND flash memory storage systems. Our technique exploits for the first time the property of the multi-page architecture of MLC NAND flash memory to improve the reliability of metadata. The basic idea is to keep metadata in most significant bit (MSB) pages which are more reliable than least significant bit (LSB) pages. Thus, we can achieve relatively low bit error rates for metadata. Based on this idea, we propose two strategies to optimize address mapping and garbage collection. We have implemented Asymmetric Programming on a real hardware platform. The experimental results show that Asymmetric Programming can achieve a reduction in the number of page errors of up to 99.05% with the baseline error correction scheme. PMID:25310473
An approximation formula for a class of fault-tolerant computers
NASA Technical Reports Server (NTRS)
White, A. L.
1986-01-01
An approximation formula is derived for the probability of failure for fault-tolerant process-control computers. These computers use redundancy and reconfiguration to achieve high reliability. Finite-state Markov models capture the dynamic behavior of component failure and system recovery, and the approximation formula permits an estimation of system reliability by an easy examination of the model.
Long life, high speed, thrust-load ball bearings
NASA Technical Reports Server (NTRS)
Signer, H.; Bamberger, E. N.; Zaretsky, E. V.
1975-01-01
Long-term bearing operation at three million DN can be achieved with high degree of reliability using full combination of sophisticated but currently available state-of-the-art bearing materials and designs, lubricants, and lubricating techniques.
Reliability study of high-brightness multiple single emitter diode lasers
NASA Astrophysics Data System (ADS)
Zhu, Jing; Yang, Thomas; Zhang, Cuipeng; Lang, Chao; Jiang, Xiaochen; Liu, Rui; Gao, Yanyan; Guo, Weirong; Jiang, Yuhua; Liu, Yang; Zhang, Luyan; Chen, Louisa
2015-03-01
In this study the chip bonding processes for various chips from various chip suppliers around the world have been optimized to achieve reliable chip on sub-mount for high performance. These chip on sub-mounts, for examples, includes three types of bonding, 8xx nm-1.2W/10.0W Indium bonded lasers, 9xx nm 10W-20W AuSn bonded lasers and 1470 nm 6W Indium bonded lasers will be reported below. The MTTF@25 of 9xx nm chip on sub-mount (COS) is calculated to be more than 203,896 hours. These chips from various chip suppliers are packaged into many multiple single emitter laser modules, using similar packaging techniques from 2 emitters per module to up to 7 emitters per module. A reliability study including aging test is performed on those multiple single emitter laser modules. With research team's 12 years' experienced packaging design and techniques, precise optical and fiber alignment processes and superior chip bonding capability, we have achieved a total MTTF exceeding 177,710 hours of life time with 60% confidence level for those multiple single emitter laser modules. Furthermore, a separated reliability study on wavelength stabilized laser modules have shown this wavelength stabilized module packaging process is reliable as well.
Murphy, Douglas J; Bruce, David A; Mercer, Stewart W; Eva, Kevin W
2009-05-01
To investigate the reliability and feasibility of six potential workplace-based assessment methods in general practice training: criterion audit, multi-source feedback from clinical and non-clinical colleagues, patient feedback (the CARE Measure), referral letters, significant event analysis, and video analysis of consultations. Performance of GP registrars (trainees) was evaluated with each tool to assess the reliabilities of the tools and feasibility, given raters and number of assessments needed. Participant experience of process determined by questionnaire. 171 GP registrars and their trainers, drawn from nine deaneries (representing all four countries in the UK), participated. The ability of each tool to differentiate between doctors (reliability) was assessed using generalisability theory. Decision studies were then conducted to determine the number of observations required to achieve an acceptably high reliability for "high-stakes assessment" using each instrument. Finally, descriptive statistics were used to summarise participants' ratings of their experience using these tools. Multi-source feedback from colleagues and patient feedback on consultations emerged as the two methods most likely to offer a reliable and feasible opinion of workplace performance. Reliability co-efficients of 0.8 were attainable with 41 CARE Measure patient questionnaires and six clinical and/or five non-clinical colleagues per doctor when assessed on two occasions. For the other four methods tested, 10 or more assessors were required per doctor in order to achieve a reliable assessment, making the feasibility of their use in high-stakes assessment extremely low. Participant feedback did not raise any major concerns regarding the acceptability, feasibility, or educational impact of the tools. The combination of patient and colleague views of doctors' performance, coupled with reliable competence measures, may offer a suitable evidence-base on which to monitor progress and completion of doctors' training in general practice.
Component Reliability Testing of Long-Life Sorption Cryocoolers
NASA Technical Reports Server (NTRS)
Bard, S.; Wu, J.; Karlmann, P.; Mirate, C.; Wade, L.
1994-01-01
This paper summarizes ongoing experiments characterizing the ability of critical sorption cryocooler components to achieve highly reliable operation for long-life space missions. Test data obtained over the past several years at JPL are entirely consistent with achieving ten year life for sorption compressors, electrical heaters, container materials, valves, and various sorbent materials suitable for driving 8 to 180 K refrigeration stages. Test results for various compressor systems are reported. Planned future tests necessary to gain a detailed understanding of the sensitivity of cooler performance and component life to operating constraints, design configurations, and fabrication, assembly and handling techniques, are also discussed.
Illustrated structural application of universal first-order reliability method
NASA Technical Reports Server (NTRS)
Verderaime, V.
1994-01-01
The general application of the proposed first-order reliability method was achieved through the universal normalization of engineering probability distribution data. The method superimposes prevailing deterministic techniques and practices on the first-order reliability method to surmount deficiencies of the deterministic method and provide benefits of reliability techniques and predictions. A reliability design factor is derived from the reliability criterion to satisfy a specified reliability and is analogous to the deterministic safety factor. Its application is numerically illustrated on several practical structural design and verification cases with interesting results and insights. Two concepts of reliability selection criteria are suggested. Though the method was developed to support affordable structures for access to space, the method should also be applicable for most high-performance air and surface transportation systems.
Fault-tolerant bandwidth reservation strategies for data transfers in high-performance networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zuo, Liudong; Zhu, Michelle M.; Wu, Chase Q.
2016-11-22
Many next-generation e-science applications need fast and reliable transfer of large volumes of data with guaranteed performance, which is typically enabled by the bandwidth reservation service in high-performance networks. One prominent issue in such network environments with large footprints is that node and link failures are inevitable, hence potentially degrading the quality of data transfer. We consider two generic types of bandwidth reservation requests (BRRs) concerning data transfer reliability: (i) to achieve the highest data transfer reliability under a given data transfer deadline, and (ii) to achieve the earliest data transfer completion time while satisfying a given data transfer reliabilitymore » requirement. We propose two periodic bandwidth reservation algorithms with rigorous optimality proofs to optimize the scheduling of individual BRRs within BRR batches. The efficacy of the proposed algorithms is illustrated through extensive simulations in comparison with scheduling algorithms widely adopted in production networks in terms of various performance metrics.« less
The military operator's experience of reliability and maintainability characteristics
NASA Astrophysics Data System (ADS)
Jones, R. Mcc.
An account is given of the British Army's approach to the achievement of high reliability and maintainability in rotorcraft during the procurement process. Attention is given to experience accumulated to date with the Gazelle, Scout, Agusta A109A, and Lynx helicopters; these offer lessons with respect to the Gem engine, fuel filtering, vibration, and an aircraft flight control system.
Boekeloo, Bradley; Randolph, Suzanne; Timmons-Brown, Stephanie; Wang, Min Qi
2014-08-01
Measures are needed to assess youth perceptions about health science careers to facilitate research aimed at increasing youth pursuit of health science. Although the Indiana Instrument provides an established measure of perceptions regarding nursing and ideal careers, we were interested in learning how high-achieving 10th graders from relatively low socioeconomic areas who identify as black/African American (black) perceive health science and ideal careers. The Indiana Instrument was modified, administered to 90 youth of interest, and psychometrically analyzed. Reliable subscales were identified that may facilitate parsimonious, theoretical, and reliable study of youth decision-making regarding health science careers. Such research may help to develop and evaluate strategies for increasing the number of minority health scientists.
NASA Technical Reports Server (NTRS)
Greenhill, L. M.
1990-01-01
The Air Force/NASA Advanced Launch System (ALS) Liquid Hydrogen Fuel Turbopump (FTP) has primary design goals of low cost and high reliability, with performance and weight having less importance. This approach is atypical compared with other rocket engine turbopump design efforts, such as on the Space Shuttle Main Engine (SSME), which emphasized high performance and low weight. Similar to the SSME turbopumps, the ALS FTP operates supercritically, which implies that stability and bearing loads strongly influence the design. In addition, the use of low cost/high reliability features in the ALS FTP such as hydrostatic bearings, relaxed seal clearances, and unshrouded turbine blades also have a negative influence on rotordynamics. This paper discusses the analysis conducted to achieve a balance between low cost and acceptable rotordynamic behavior, to ensure that the ALS FTP will operate reliably without subsynchronous instabilities or excessive bearing loads.
Enabling technologies for fiber optic sensing
NASA Astrophysics Data System (ADS)
Ibrahim, Selwan K.; Farnan, Martin; Karabacak, Devrez M.; Singer, Johannes M.
2016-04-01
In order for fiber optic sensors to compete with electrical sensors, several critical parameters need to be addressed such as performance, cost, size, reliability, etc. Relying on technologies developed in different industrial sectors helps to achieve this goal in a more efficient and cost effective way. FAZ Technology has developed a tunable laser based optical interrogator based on technologies developed in the telecommunication sector and optical transducer/sensors based on components sourced from the automotive market. Combining Fiber Bragg Grating (FBG) sensing technology with the above, high speed, high precision, reliable quasi distributed optical sensing systems for temperature, pressure, acoustics, acceleration, etc. has been developed. Careful design needs to be considered to filter out any sources of measurement drifts/errors due to different effects e.g. polarization and birefringence, coating imperfections, sensor packaging etc. Also to achieve high speed and high performance optical sensing systems, combining and synchronizing multiple optical interrogators similar to what has been used with computer/processors to deliver super computing power is an attractive solution. This path can be achieved by using photonic integrated circuit (PIC) technology which opens the doors to scaling up and delivering powerful optical sensing systems in an efficient and cost effective way.
Miciak, Jeremy; Taylor, Pat; Denton, Carolyn A.; Fletcher, Jack M.
2014-01-01
Purpose Few empirical investigations have evaluated learning disabilities (LD) identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability of LD classification decisions of the concordance/discordance method (C/DM) across different psychoeducational assessment batteries. Methods C/DM criteria were applied to assessment data from 177 second grade students based on two psychoeducational assessment batteries. The achievement tests were different, but were highly correlated and measured the same latent construct. Resulting LD identifications were then evaluated for agreement across batteries on LD status and the academic domain of eligibility. Results The two batteries identified a similar number of participants as having LD (80 and 74). However, indices of agreement for classification decisions were low (kappa = .29), especially for percent positive agreement (62%). The two batteries demonstrated agreement on the academic domain of eligibility for only 25 participants. Conclusions Cognitive discrepancy frameworks for LD identification are inherently unstable because of imperfect reliability and validity at the observed level. Methods premised on identifying a PSW profile may never achieve high reliability because of these underlying psychometric factors. An alternative is to directly assess academic skills to identify students in need of intervention. PMID:25243467
Science Anxiety: Relation with Gender, Year in Chemistry Class, Achievement, and Test Anxiety.
ERIC Educational Resources Information Center
Wynstra, Sharon; Cummings, Corenna
The relationships of science anxiety to measures of achievement, test anxiety, year of chemistry taken, and gender were investigated for high school students; the study also attemped to establish reliability data on the Czerniak Assessment of Science Anxiety (CASA) of L. Chiarelott and C. Czerniak (1987). Subjects were 101 students (45 males and…
Reliable 6 PEP LTPS device for AMOLED's
NASA Astrophysics Data System (ADS)
Chou, Cheng-Wei; Wang, Pei-Yun; Hu, Chin-Wei; Chang, York; Chuang, Ching-Sang; Lin, Yusin
2013-09-01
This study presents a TFT structure which has less photo process and higher cost competitiveness in AMOLED display markets. A novel LTPS based 6 masks TFT structure for bottom emission AMOLED display is demonstrated in this paper. High field effect mobility (PMOS < 80 cm2/Vs ) and high reliability (PBTS △Vth< 0.02V @ 50oC VG=15V 10ks) was accomplished without the high temperature and rapid thermal annealing (RTA) activation process. Furthermore, a 14-inch AMOLED TV was achieved on the proposed 6-pep TFT backplane using the Gen. 3.5 mass production factory.
Probabilistic Assessment of High-Throughput Wireless Sensor Networks
Kim, Robin E.; Mechitov, Kirill; Sim, Sung-Han; Spencer, Billie F.; Song, Junho
2016-01-01
Structural health monitoring (SHM) using wireless smart sensors (WSS) has the potential to provide rich information on the state of a structure. However, because of their distributed nature, maintaining highly robust and reliable networks can be challenging. Assessing WSS network communication quality before and after finalizing a deployment is critical to achieve a successful WSS network for SHM purposes. Early studies on WSS network reliability mostly used temporal signal indicators, composed of a smaller number of packets, to assess the network reliability. However, because the WSS networks for SHM purpose often require high data throughput, i.e., a larger number of packets are delivered within the communication, such an approach is not sufficient. Instead, in this study, a model that can assess, probabilistically, the long-term performance of the network is proposed. The proposed model is based on readily-available measured data sets that represent communication quality during high-throughput data transfer. Then, an empirical limit-state function is determined, which is further used to estimate the probability of network communication failure. Monte Carlo simulation is adopted in this paper and applied to a small and a full-bridge wireless networks. By performing the proposed analysis in complex sensor networks, an optimized sensor topology can be achieved. PMID:27258270
Study of complete interconnect reliability for a GaAs MMIC power amplifier
NASA Astrophysics Data System (ADS)
Lin, Qian; Wu, Haifeng; Chen, Shan-ji; Jia, Guoqing; Jiang, Wei; Chen, Chao
2018-05-01
By combining the finite element analysis (FEA) and artificial neural network (ANN) technique, the complete prediction of interconnect reliability for a monolithic microwave integrated circuit (MMIC) power amplifier (PA) at the both of direct current (DC) and alternating current (AC) operation conditions is achieved effectively in this article. As a example, a MMIC PA is modelled to study the electromigration failure of interconnect. This is the first time to study the interconnect reliability for an MMIC PA at the conditions of DC and AC operation simultaneously. By training the data from FEA, a high accuracy ANN model for PA reliability is constructed. Then, basing on the reliability database which is obtained from the ANN model, it can give important guidance for improving the reliability design for IC.
An assessment of the real-time application capabilities of the SIFT computer system
NASA Technical Reports Server (NTRS)
Butler, R. W.
1982-01-01
The real-time capabilities of the SIFT computer system, a highly reliable multicomputer architecture developed to support the flight controls of a relaxed static stability aircraft, are discussed. The SIFT computer system was designed to meet extremely high reliability requirements and to facilitate a formal proof of its correctness. Although SIFT represents a significant achievement in fault-tolerant system research it presents an unusual and restrictive interface to its users. The characteristics of the user interface and its impact on application system design are assessed.
Reliability and coverage analysis of non-repairable fault-tolerant memory systems
NASA Technical Reports Server (NTRS)
Cox, G. W.; Carroll, B. D.
1976-01-01
A method was developed for the construction of probabilistic state-space models for nonrepairable systems. Models were developed for several systems which achieved reliability improvement by means of error-coding, modularized sparing, massive replication and other fault-tolerant techniques. From the models developed, sets of reliability and coverage equations for the systems were developed. Comparative analyses of the systems were performed using these equation sets. In addition, the effects of varying subunit reliabilities on system reliability and coverage were described. The results of these analyses indicated that a significant gain in system reliability may be achieved by use of combinations of modularized sparing, error coding, and software error control. For sufficiently reliable system subunits, this gain may far exceed the reliability gain achieved by use of massive replication techniques, yet result in a considerable saving in system cost.
Levac, Danielle; Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi
2016-06-01
Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements.
Nawrotek, Joanna; Deschenes, Emilie; Giguere, Tia; Serafin, Julie; Bilodeau, Martin; Sveistrup, Heidi
2016-01-01
Background Virtual reality active video games are increasingly popular physical therapy interventions for children with cerebral palsy. However, physical therapists require educational resources to support decision making about game selection to match individual patient goals. Quantifying the movements elicited during virtual reality active video game play can inform individualized game selection in pediatric rehabilitation. Objective The objectives of this study were to develop and evaluate the feasibility and reliability of the Movement Rating Instrument for Virtual Reality Game Play (MRI-VRGP). Methods Item generation occurred through an iterative process of literature review and sample videotape viewing. The MRI-VRGP includes 25 items quantifying upper extremity, lower extremity, and total body movements. A total of 176 videotaped 90-second game play sessions involving 7 typically developing children and 4 children with cerebral palsy were rated by 3 raters trained in MRI-VRGP use. Children played 8 games on 2 virtual reality and active video game systems. Intraclass correlation coefficients (ICCs) determined intra-rater and interrater reliability. Results Excellent intrarater reliability was evidenced by ICCs of >0.75 for 17 of the 25 items across the 3 raters. Interrater reliability estimates were less precise. Excellent interrater reliability was achieved for far reach upper extremity movements (ICC=0.92 [for right and ICC=0.90 for left) and for squat (ICC=0.80) and jump items (ICC=0.99), with 9 items achieving ICCs of >0.70, 12 items achieving ICCs of between 0.40 and 0.70, and 4 items achieving poor reliability (close-reach upper extremity-ICC=0.14 for right and ICC=0.07 for left) and single-leg stance (ICC=0.55 for right and ICC=0.27 for left). Conclusions Poor video quality, differing item interpretations between raters, and difficulty quantifying the high-speed movements involved in game play affected reliability. With item definition clarification and further psychometric property evaluation, the MRI-VRGP could inform the content of educational resources for therapists by ranking games according to frequency and type of elicited body movements. PMID:27251029
NASA Astrophysics Data System (ADS)
Kondo, Yoshihisa; Yomo, Hiroyuki; Yamaguchi, Shinji; Davis, Peter; Miura, Ryu; Obana, Sadao; Sampei, Seiichi
This paper proposes multipoint-to-multipoint (MPtoMP) real-time broadcast transmission using network coding for ad-hoc networks like video game networks. We aim to achieve highly reliable MPtoMP broadcasting using IEEE 802.11 media access control (MAC) that does not include a retransmission mechanism. When each node detects packets from the other nodes in a sequence, the correctly detected packets are network-encoded, and the encoded packet is broadcasted in the next sequence as a piggy-back for its native packet. To prevent increase of overhead in each packet due to piggy-back packet transmission, network coding vector for each node is exchanged between all nodes in the negotiation phase. Each user keeps using the same coding vector generated in the negotiation phase, and only coding information that represents which user signal is included in the network coding process is transmitted along with the piggy-back packet. Our simulation results show that the proposed method can provide higher reliability than other schemes using multi point relay (MPR) or redundant transmissions such as forward error correction (FEC). We also implement the proposed method in a wireless testbed, and show that the proposed method achieves high reliability in a real-world environment with a practical degree of complexity when installed on current wireless devices.
ERIC Educational Resources Information Center
What Works Clearinghouse, 2012
2012-01-01
This study examined five instruments used to assess the effectiveness of teacher practices based on classroom observations. The study first examined whether observers could reliably assess teachers with each instrument, and then examined how well each instrument, along with other information, predicted student achievement. The study reported that,…
[Validation and adhesion to GESIDA quality indicators in patients with HIV infection].
Riera, Melchor; Esteban, Herminia; Suarez, Ignacio; Palacios, Rosario; Lozano, Fernando; Blanco, Jose R; Valencia, Eulalia; Ocampo, Antonio; Amador, Concha; Frontera, Guillem; vonWichmann-de Miguel, Miguel Angel
2016-01-01
The objective of the study is to validate the relevant GESIDA quality indicators for HIV infection, assessing the reliability, feasibility and adherence to them. The reliability was evaluated using the reproducibility of 6 indicators in peer review, with the second observer being an outsider. The feasibility and measurement of the level of adherence to the 22 indicators was conducted with annual fragmented retrospective collection of information from specific databases or the clinical charts of the nine participating hospitals. Reliability was very high, with interobserver agreement levels higher than 95% in 5 of the 6 indicators. The median time to achieve the indicators ranged between 5 and 600minutes, but could be achieved progressively from specific databases, enabling obtaining them automatically. As regards adherence to the indicators related with the initial evaluation of the patients, instructions and suitability of the guidelines for ART, adherence to ART, follow-up in clinics, and achieve an undetectable HIV by PCR at week 48 of the ART. Indicators of quality related to the prevention of opportunistic infections and control of comorbidities, the standards set were not achieved, and significant heterogeneity was observed between hospitals. The GESIDA quality indicators of HIV infection enabled the relevant indicators to be feasibly and reliably measured, and should be collected in all the units that care for patients with HIV infection. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Synthetic chemists have always had an objective to achieve reliable and high-yielding routes to the syntheses of targeted molecules. The importance of minimal waste generation has emphasized the use of green chemistry principles and sustainable development. These directions lead ...
NASA Astrophysics Data System (ADS)
Chou, Yeong-Chang; Leung, Denise; Lai, Richard; Grundbacher, Ron; Scarpulla, John; Barsky, Mike; Nishimoto, Matt; Eng, David; Liu, Po-Hsin; Oki, Aaron; Streit, Dwight
2002-02-01
The high-reliability performance of K-band microwave monolithic integrated circuit (MMIC) amplifiers fabricated with 0.1 μm gate length InGaAs/InAlAs/InP high electron mobility transistors (HEMTs) on 3-inch wafers using a high volume production process technology is reported. Operating at an accelerated life test condition of Vds=1.5 V and Ids=150 mA/mm, two-stage balanced amplifiers were lifetested at two-temperatures (T1=230°C, and T2=250°C) in nitrogen ambient. The activation energy (Ea) is as high as 1.5 eV, achieving a projected median-time-to-failure (MTTF) >1× 106 h at a 125°C of junction temperature. MTTF was determined by 2-temperature constant current stress using |Δ S21|>1.0 dB as the failure criteria. This is the first report of high reliability 0.1 μm InGaAs/InAlAs/InP HEMT MMICs based on small-signal microwave characteristics. This result demonstrates a reliable InGaAs/InAlAs/InP HEMT production technology.
NASA Astrophysics Data System (ADS)
Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey
2018-05-01
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.
Gray, Vicki L; Ivanova, Tanya D; Garland, S Jayne
2014-01-01
Knowing the reliability of the center of pressure (COP) is important for interpreting balance deficits post-stroke, especially when the balance deficits can necessitate the use of short duration trials. The novel aspect of this reliability study was to examine the center of pressure measures using two adjacent force platforms between and within sessions in stroke and controls. After stroke, it is important to understand the contribution of the paretic and non-paretic leg to the motor control of standing balance. Because there is a considerable body of knowledge on COP reliability on a single platform, we chose to examine reliability using two adjacent platforms which has not been examined previously in stroke. Twenty participants post-stroke and 22 controls performed an arm raise, load drop and quiet stance balance task while standing on two adjacent force platforms, on two separate days. Intraclass correlations coefficient (ICC2,1) and percentage standard error of measurement (SEM%) were calculated for COP velocity, ellipse area, anterior-posterior (AP) displacement, and medial-lateral (ML) displacement. Between sessions, COP velocity was the most reliable with high ICCs and low SEM% across groups and tasks and ellipse area was less reliable with low ICCs across groups and tasks. COP measures were less reliable during the arm raise than load drop post-stroke. Within session reliability was high for COP velocity and ML displacement requiring no more than six trials across tasks. The COP velocity was the most reliable measure with high ICCs between sessions and the high reliability was achieved with fewer trials in both groups in a single session. Copyright © 2014 Elsevier B.V. All rights reserved.
Reliability systems for implantable cardiac defibrillator batteries
NASA Astrophysics Data System (ADS)
Takeuchi, Esther S.
The reliability of the power sources used in implantable cardiac defibrillators is critical due to the life-saving nature of the device. Achieving a high reliability power source depends on several systems functioning together. Appropriate cell design is the first step in assuring a reliable product. Qualification of critical components and of the cells using those components is done prior to their designation as implantable grade. Product consistency is assured by control of manufacturing practices and verified by sampling plans using both accelerated and real-time testing. Results to date show that lithium/silver vanadium oxide cells used for implantable cardiac defibrillators have a calculated maximum random failure rate of 0.005% per test month.
2012-09-30
Development of Sand Properties 103 Advanced Modeling Dataset.. 105 High Strength Low Alloy (HSLA) Steels 107 Steel Casting and Engineering Support...to achieve the performance goals required for new systems. The dramatic reduction in weight and increase in capability will require high performance...for improved weapon system reliability. SFSA developed innovative casting design and manufacturing processes for high performance parts. SFSA is
McLean, Heather S; Carriker, Charlene; Bordley, William Clay
2017-04-01
The Joint Commission, the Centers for Disease Control and Prevention, and the World Health Organization challenge hospitals to achieve and sustain compliance with effective hand hygiene (HH) practice; however, many inpatient units fail to achieve a high level of reliability. The aim of the project was to increase and sustain health care worker (HCW) compliance with HH protocols from 87% (level of reliability [LOR] 1) to ≥95% (LOR 2) within 9 months on 2 pediatric inpatient units in an academic children's hospital. This study was a time-series, quality-improvement project. Interventions were tested through multiple plan-do-study-act cycles on 2 pediatric inpatient units. HH compliance audits of HCWs on these units were performed randomly each week by the hospital infection prevention program. Control charts of percentages of HCW HH compliance were constructed with 3-σ (data within 3 SDs from a mean) control limits. These control limits were adjusted after achieving significant improvements in performance over time. Charts were annotated with interventions including (1) increasing awareness, (2) providing timely feedback, (3) empowering patients and families to participate in mitigation, (4) providing focused education, and (5) developing interdisciplinary HH champions. HH compliance rates improved from an average of 87% (LOR 1) to ≥95% (LOR 2) within 9 months, and this improvement has been sustained for >2 years on both pediatric inpatient units. Significant and sustained gains in HH compliance rates of ≥95% (LOR 2) can be achieved by applying high-reliability human-factor interventions. Copyright © 2017 by the American Academy of Pediatrics.
Training and Maintaining System-Wide Reliability in Outcome Management.
Barwick, Melanie A; Urajnik, Diana J; Moore, Julia E
2014-01-01
The Child and Adolescent Functional Assessment Scale (CAFAS) is widely used for outcome management, for providing real time client and program level data, and the monitoring of evidence-based practices. Methods of reliability training and the assessment of rater drift are critical for service decision-making within organizations and systems of care. We assessed two approaches for CAFAS training: external technical assistance and internal technical assistance. To this end, we sampled 315 practitioners trained by external technical assistance approach from 2,344 Ontario practitioners who had achieved reliability on the CAFAS. To assess the internal technical assistance approach as a reliable alternative training method, 140 practitioners trained internally were selected from the same pool of certified raters. Reliabilities were high for both practitioners trained by external technical assistance and internal technical assistance approaches (.909-.995, .915-.997, respectively). 1 and 3-year estimates showed some drift on several scales. High and consistent reliabilities over time and training method has implications for CAFAS training of behavioral health care practitioners, and the maintenance of CAFAS as a global outcome management tool in systems of care.
Reliability model for ductile hybrid FRP rebar using randomly dispersed chopped fibers
NASA Astrophysics Data System (ADS)
Behnam, Bashar Ramzi
Fiber reinforced polymer composites or simply FRP composites have become more attractive to civil engineers in the last two decades due to their unique mechanical properties. However, there are many obstacles such as low elasticity modulus, non-ductile behavior, high cost of the fibers, high manufacturing costs, and absence of rigorous characterization of the uncertainties of the mechanical properties that restrict the use of these composites. However, when FRP composites are used to develop reinforcing rebars in concrete structural members to replace the conventional steel, a huge benefit can be achieved since FRP materials don't corrode. Two FRP rebar models are proposed that make use of multiple types of fibers to achieve ductility, and chopped fibers are used to reduce the manufacturing costs. In order to reach the most optimum fractional volume of each type of fiber, to minimize the cost of the proposed rebars, and to achieve a safe design by considering uncertainties in the materials and geometry of sections, appropriate material resistance factors have been developed, and a Reliability Based Design Optimization (RBDO), has been conducted for the proposed schemes.
ERIC Educational Resources Information Center
Khodadady, Ebrahim; Pishghadam, Reza; Alaee, Farnaz Farokh
2012-01-01
An achievement test based on schema theory (S-Test) was developed on the passages comprising the English textbook taught at grade three in state high schools in Iran and administered concurrently with a validated and reliable Social Capital Scale (SCS) to four hundred seventy seven male and female participants. The Z-scores obtained on the S-Test…
Validity and reliability of a new ankle dorsiflexion measurement device.
Gatt, Alfred; Chockalingam, Nachiappan
2013-08-01
The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.
Error control techniques for satellite and space communications
NASA Technical Reports Server (NTRS)
Costello, D. J., Jr.
1986-01-01
High rate concatenated coding systems with trellis inner codes and Reed-Solomon (RS) outer codes for application in satellite communication systems are considered. Two types of inner codes are studied: high rate punctured binary convolutional codes which result in overall effective information rates between 1/2 and 1 bit per channel use; and bandwidth efficient signal space trellis codes which can achieve overall effective information rates greater than 1 bit per channel use. Channel capacity calculations with and without side information performed for the concatenated coding system. Concatenated coding schemes are investigated. In Scheme 1, the inner code is decoded with the Viterbi algorithm and the outer RS code performs error-correction only (decoding without side information). In scheme 2, the inner code is decoded with a modified Viterbi algorithm which produces reliability information along with the decoded output. In this algorithm, path metrics are used to estimate the entire information sequence, while branch metrics are used to provide the reliability information on the decoded sequence. This information is used to erase unreliable bits in the decoded output. An errors-and-erasures RS decoder is then used for the outer code. These two schemes are proposed for use on NASA satellite channels. Results indicate that high system reliability can be achieved with little or no bandwidth expansion.
Flitter, Marc A; Riesenmy, Kelly Rouse; van Stralen, Daved
2012-01-01
To offer a theoretical explanation for observed physician resistance and rejection of high reliability patient safety initiatives. A grounded theoretical qualitative approach, utilizing the organizational theory of sensemaking, provided the foundation for inductive and deductive reasoning employed to analyze medical staff rejection of two successfully performing high reliability programs at separate hospitals. Physician behaviors resistant to patient-centric high reliability processes were traced to provider-centric physician sensemaking. Research, conducted with the advantage that prospective studies have over the limitations of this retrospective investigation, is needed to evaluate the potential for overcoming physician resistance to innovation implementation, employing strategies based upon these findings and sensemaking theory in general. If hospitals are to emulate high reliability industries that do successfully manage environments of extreme hazard, physicians must be fully integrated into the complex teams required to accomplish this goal. Reforming health care, through high reliability organizing, with its attendant continuous focus on patient-centric processes, offers a distinct alternative to efforts directed primarily at reforming health care insurance. It is by changing how health care is provided that true cost efficiencies can be achieved. Technology and the insights of organizational science present the opportunity of replacing the current emphasis on privileged information with collective tools capable of providing quality and safety in health care. The fictions that have sustained a provider-centric health care system have been challenged. The benefits of patient-centric care should be obtainable.
Shortell, Stephen M
2016-12-01
This commentary highights the key arguments and contributions of institutional thoery, transaction cost economics (TCE) theory, high reliability theory, and organizational learning theory to understanding the development and evolution of Accountable Care Organizations (ACOs). Institutional theory and TCE theory primarily emphasize the external influences shaping ACOs while high reliability theory and organizational learning theory underscore the internal fctors influencing ACO perfromance. A framework based on Implementation Science is proposed to conside the multiple perspectives on ACOs and, in particular, their abiity to innovate to achieve desired cost, quality, and population health goals. © The Author(s) 2016.
A probability-based approach for assessment of roadway safety hardware.
DOT National Transportation Integrated Search
2017-03-14
This report presents a general probability-based approach for assessment of roadway safety hardware (RSH). It was achieved using a reliability : analysis method and computational techniques. With the development of high-fidelity finite element (FE) m...
ERIC Educational Resources Information Center
Schaffer, Eugene; Reynolds, David; Stringfield, Sam
2012-01-01
Beginning from 1 high-poverty, historically low-achieving secondary school's successful turnaround work, this article provides data relative to a successful school turnaround, the importance of external and system-level supports, and the importance of building for sustainable institutionalization of improvements. The evidence suggests the…
High rate concatenated coding systems using bandwidth efficient trellis inner codes
NASA Technical Reports Server (NTRS)
Deng, Robert H.; Costello, Daniel J., Jr.
1989-01-01
High-rate concatenated coding systems with bandwidth-efficient trellis inner codes and Reed-Solomon (RS) outer codes are investigated for application in high-speed satellite communication systems. Two concatenated coding schemes are proposed. In one the inner code is decoded with soft-decision Viterbi decoding, and the outer RS code performs error-correction-only decoding (decoding without side information). In the other, the inner code is decoded with a modified Viterbi algorithm, which produces reliability information along with the decoded output. In this algorithm, path metrics are used to estimate the entire information sequence, whereas branch metrics are used to provide reliability information on the decoded sequence. This information is used to erase unreliable bits in the decoded output. An errors-and-erasures RS decoder is then used for the outer code. The two schemes have been proposed for high-speed data communication on NASA satellite channels. The rates considered are at least double those used in current NASA systems, and the results indicate that high system reliability can still be achieved.
Frankel, Allan S; Leonard, Michael W; Denham, Charles R
2006-01-01
Background Disparate health care provider attitudes about autonomy, teamwork, and administrative operations have added to the complexity of health care delivery and are a central factor in medicine's unacceptably high rate of errors. Other industries have improved their reliability by applying innovative concepts to interpersonal relationships and administrative hierarchical structures (Chandler 1962). In the last 10 years the science of patient safety has become more sophisticated, with practical concepts identified and tested to improve the safety and reliability of care. Objective Three initiatives stand out as worthy regarding interpersonal relationships and the application of provider concerns to shape operational change: The development and implementation of Fair and Just Culture principles, the broad use of Teamwork Training and Communication, and tools like WalkRounds that promote the alignment of leadership and frontline provider perspectives through effective use of adverse event data and provider comments. Methods Fair and Just Culture, Teamwork Training, and WalkRounds are described, and implementation examples provided. The argument is made that they must be systematically and consistently implemented in an integrated fashion. Conclusions There are excellent examples of institutions applying Just Culture principles, Teamwork Training, and Leadership WalkRounds—but to date, they have not been comprehensively instituted in health care organizations in a cohesive and interdependent manner. To achieve reliability, organizations need to begin thinking about the relationship between these efforts and linking them conceptually. PMID:16898986
Reliability analysis and utilization of PEMs in space application
NASA Astrophysics Data System (ADS)
Jiang, Xiujie; Wang, Zhihua; Sun, Huixian; Chen, Xiaomin; Zhao, Tianlin; Yu, Guanghua; Zhou, Changyi
2009-11-01
More and more plastic encapsulated microcircuits (PEMs) are used in space missions to achieve high performance. Since PEMs are designed for use in terrestrial operating conditions, the successful usage of PEMs in space harsh environment is closely related to reliability issues, which should be considered firstly. However, there is no ready-made methodology for PEMs in space applications. This paper discusses the reliability for the usage of PEMs in space. This reliability analysis can be divided into five categories: radiation test, radiation hardness, screening test, reliability calculation and reliability assessment. One case study is also presented to illuminate the details of the process, in which a PEM part is used in a joint space program Double-Star Project between the European Space Agency (ESA) and China. The influence of environmental constrains including radiation, humidity, temperature and mechanics on the PEM part has been considered. Both Double-Star Project satellites are still running well in space now.
Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho
2014-02-14
Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10,000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm(-2). The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.
NASA Astrophysics Data System (ADS)
Kim, Jae-Woo; Jeong, Jin-Woo; Kang, Jun-Tae; Choi, Sungyoul; Ahn, Seungjoon; Song, Yoon-Ho
2014-02-01
Highly reliable field electron emitters were developed using a formulation for reproducible damage-free carbon nanotube (CNT) composite pastes with optimal inorganic fillers and a ball-milling method. We carefully controlled the ball-milling sequence and time to avoid any damage to the CNTs, which incorporated fillers that were fully dispersed as paste constituents. The field electron emitters fabricated by printing the CNT pastes were found to exhibit almost perfect adhesion of the CNT emitters to the cathode, along with good uniformity and reproducibility. A high field enhancement factor of around 10 000 was achieved from the CNT field emitters developed. By selecting nano-sized metal alloys and oxides and using the same formulation sequence, we also developed reliable field emitters that could survive high-temperature post processing. These field emitters had high durability to post vacuum annealing at 950 °C, guaranteeing survival of the brazing process used in the sealing of field emission x-ray tubes. We evaluated the field emitters in a triode configuration in the harsh environment of a tiny vacuum-sealed vessel and observed very reliable operation for 30 h at a high current density of 350 mA cm-2. The CNT pastes and related field emitters that were developed could be usefully applied in reliable field emission devices.
High reliability linear drive device for artificial hearts
NASA Astrophysics Data System (ADS)
Ji, Jinghua; Zhao, Wenxiang; Liu, Guohai; Shen, Yue; Wang, Fangqun
2012-04-01
In this paper, a new high reliability linear drive device, termed as stator-permanent-magnet tubular oscillating actuator (SPM-TOA), is proposed for artificial hearts (AHs). The key is to incorporate the concept of two independent phases into this linear AH device, hence achieving high reliability operation. The fault-tolerant teeth are employed to provide the desired decoupling phases in magnetic circuit. Also, as the magnets and the coils are located in the stator, the proposed SPM-TOA takes the definite advantages of robust mover and direct-drive capability. By using the time-stepping finite element method, the electromagnetic characteristics of the proposed SPM-TOA are analyzed, including magnetic field distributions, flux linkages, back- electromotive forces (back-EMFs) self- and mutual inductances, as well as cogging and thrust forces. The results confirm that the proposed SPM-TOA meets the dimension, weight, and force requirements of the AH drive device.
Managing unexpected events in the manufacturing of biologic medicines.
Grampp, Gustavo; Ramanan, Sundar
2013-08-01
The manufacturing of biologic medicines (biologics) requires robust process and facility design, rigorous regulatory compliance, and a well-trained workforce. Because of the complex attributes of biologics and their sensitivity to production and handling conditions, manufacturing of these medicines also requires a high-reliability manufacturing organization. As required by regulators, such an organization must monitor the state-of-control for the manufacturing process. A high-reliability organization also invests in an experienced and fully engaged technical support staff and fosters a management culture that rewards in-depth analysis of unexpected results, robust risk assessments, and timely and effective implementation of mitigation measures. Such a combination of infrastructure, technology, human capital, management, and a science-based operations culture does not occur without a strong organizational and financial commitment. These attributes of a high-reliability biologics manufacturer are difficult to achieve and may be differentiating factors as the supply of biologics diversifies in future years.
TCOPPE school environmental audit tool: assessing safety and walkability of school environments.
Lee, Chanam; Kim, Hyung Jin; Dowdy, Diane M; Hoelscher, Deanna M; Ory, Marcia G
2013-09-01
Several environmental audit instruments have been developed for assessing streets, parks and trails, but none for schools. This paper introduces a school audit tool that includes 3 subcomponents: 1) street audit, 2) school site audit, and 3) map audit. It presents the conceptual basis and the development process of this instrument, and the methods and results of the reliability assessments. Reliability tests were conducted by 2 trained auditors on 12 study schools (high-low income and urban-suburban-rural settings). Kappa statistics (categorical, factual items) and ICC (Likert-scale, perceptual items) were used to assess a) interrater, b) test-retest, and c) peak vs. off-peak hour reliability tests. For the interrater reliability test, the average Kappa was 0.839 and the ICC was 0.602. For the test-retest reliability, the average Kappa was 0.903 and the ICC was 0.774. The peak-off peak reliability was 0.801. Rural schools showed the most consistent results in the peak-off peak and test-retest assessments. For interrater tests, urban schools showed the highest ICC, and rural schools showed the highest Kappa. Most items achieved moderate to high levels of reliabilities in all study schools. With proper training, this audit can be used to assess school environments reliably for research, outreach, and policy-support purposes.
Development of high-speed rolling-element bearings. A historical and technical perspective
NASA Technical Reports Server (NTRS)
Zaretsky, E. V.
1982-01-01
Research on large-bore ball and roller bearings for aircraft engines is described. Tapered roller bearings and small-bore bearings are discussed. Temperature capabilities of rolling element bearings for aircraft engines have moved from 450 to 589 K (350 to 600 F) with increased reliability. High bearing speeds to 3 million DN can be achieved with a reliability exceeding that which was common in commercial aircraft. Capabilities of available bearing steels and lubricants were defined and established. Computer programs for the analysis and design of rolling element bearings were developed and experimentally verified. The reported work is a summary of NASA contributions to high performance engine and transmission bearing capabilities.
Design and implementation of online automatic judging system
NASA Astrophysics Data System (ADS)
Liang, Haohui; Chen, Chaojie; Zhong, Xiuyu; Chen, Yuefeng
2017-06-01
For lower efficiency and poorer reliability in programming training and competition by currently artificial judgment, design an Online Automatic Judging (referred to as OAJ) System. The OAJ system including the sandbox judging side and Web side, realizes functions of automatically compiling and running the tested codes, and generating evaluation scores and corresponding reports. To prevent malicious codes from damaging system, the OAJ system utilizes sandbox, ensuring the safety of the system. The OAJ system uses thread pools to achieve parallel test, and adopt database optimization mechanism, such as horizontal split table, to improve the system performance and resources utilization rate. The test results show that the system has high performance, high reliability, high stability and excellent extensibility.
Extending the wavelength range in the Oclaro high-brightness broad area modules
NASA Astrophysics Data System (ADS)
Pawlik, Susanne; Guarino, Andrea; Sverdlov, Boris; Müller, Jürgen; Button, Christopher; Arlt, Sebastian; Jaeggi, Dominik; Lichtenstein, Norbert
2010-02-01
The demand for high power laser diode modules in the wavelength range between 793 nm and 1060 nm has been growing continuously over the last several years. Progress in eye-safe fiber lasers requires reliable pump power at 793 nm, modules at 808 nm are used for small size DPSSL applications and fiber-coupled laser sources at 830 nm are used in printing industry. However, power levels achieved in this wavelength range have remained lower than for the 9xx nm range. Here we report on approaches to increasing the reliable power in our latest generations of high power pump modules in the wavelength range between 793 nm and 1060 nm.
ERIC Educational Resources Information Center
Cizek, Gregory J.
2009-01-01
Reliability and validity are two characteristics that must be considered whenever information about student achievement is collected. However, those characteristics--and the methods for evaluating them--differ in large-scale testing and classroom testing contexts. This article presents the distinctions between reliability and validity in the two…
Design and Scheduling of Microgrids using Benders Decomposition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nagarajan, Adarsh; Ayyanar, Raja
2016-11-21
The distribution feeder laterals in a distribution feeder with relatively high PV generation as compared to the load can be operated as microgrids to achieve reliability, power quality and economic benefits. However, renewable resources are intermittent and stochastic in nature. A novel approach for sizing and scheduling an energy storage system and microturbine for reliable operation of microgrids is proposed. The size and schedule of an energy storage system and microturbine are determined using Benders' decomposition, considering PV generation as a stochastic resource.
NASA Astrophysics Data System (ADS)
Tanakamaru, Shuhei; Fukuda, Mayumi; Higuchi, Kazuhide; Esumi, Atsushi; Ito, Mitsuyoshi; Li, Kai; Takeuchi, Ken
2011-04-01
A dynamic codeword transition ECC scheme is proposed for highly reliable solid-state drives, SSDs. By monitoring the error number or the write/erase cycles, the ECC codeword dynamically increases from 512 Byte (+parity) to 1 KByte, 2 KByte, 4 KByte…32 KByte. The proposed ECC with a larger codeword decreases the failure rate after ECC. As a result, the acceptable raw bit error rate, BER, before ECC is enhanced. Assuming a NAND Flash memory which requires 8-bit correction in 512 Byte codeword ECC, a 17-times higher acceptable raw BER than the conventional fixed 512 Byte codeword ECC is realized for the mobile phone application without an interleaving. For the MP3 player, digital-still camera and high-speed memory card applications with a dual channel interleaving, 15-times higher acceptable raw BER is achieved. Finally, for the SSD application with 8 channel interleaving, 13-times higher acceptable raw BER is realized. Because the ratio of the user data to the parity bits is the same in each ECC codeword, no additional memory area is required. Note that the reliability of SSD is improved after the manufacturing without cost penalty. Compared with the conventional ECC with the fixed large 32 KByte codeword, the proposed scheme achieves a lower power consumption by introducing the "best-effort" type operation. In the proposed scheme, during the most of the lifetime of SSD, a weak ECC with a shorter codeword such as 512 Byte (+parity), 1 KByte and 2 KByte is used and 98% lower power consumption is realized. At the life-end of SSD, a strong ECC with a 32 KByte codeword is used and the highly reliable operation is achieved. The random read performance is also discussed. The random read performance is estimated by the latency. The latency is below 1.5 ms for ECC codeword up to 32 KByte. This latency is below the average latency of 15,000 rpm HDD, 2 ms.
Chen, Qingkui; Zhao, Deyu; Wang, Jingjuan
2017-01-01
This paper aims to develop a low-cost, high-performance and high-reliability computing system to process large-scale data using common data mining algorithms in the Internet of Things (IoT) computing environment. Considering the characteristics of IoT data processing, similar to mainstream high performance computing, we use a GPU (Graphics Processing Unit) cluster to achieve better IoT services. Firstly, we present an energy consumption calculation method (ECCM) based on WSNs. Then, using the CUDA (Compute Unified Device Architecture) Programming model, we propose a Two-level Parallel Optimization Model (TLPOM) which exploits reasonable resource planning and common compiler optimization techniques to obtain the best blocks and threads configuration considering the resource constraints of each node. The key to this part is dynamic coupling Thread-Level Parallelism (TLP) and Instruction-Level Parallelism (ILP) to improve the performance of the algorithms without additional energy consumption. Finally, combining the ECCM and the TLPOM, we use the Reliable GPU Cluster Architecture (RGCA) to obtain a high-reliability computing system considering the nodes’ diversity, algorithm characteristics, etc. The results show that the performance of the algorithms significantly increased by 34.1%, 33.96% and 24.07% for Fermi, Kepler and Maxwell on average with TLPOM and the RGCA ensures that our IoT computing system provides low-cost and high-reliability services. PMID:28777325
Fang, Yuling; Chen, Qingkui; Xiong, Neal N; Zhao, Deyu; Wang, Jingjuan
2017-08-04
This paper aims to develop a low-cost, high-performance and high-reliability computing system to process large-scale data using common data mining algorithms in the Internet of Things (IoT) computing environment. Considering the characteristics of IoT data processing, similar to mainstream high performance computing, we use a GPU (Graphics Processing Unit) cluster to achieve better IoT services. Firstly, we present an energy consumption calculation method (ECCM) based on WSNs. Then, using the CUDA (Compute Unified Device Architecture) Programming model, we propose a Two-level Parallel Optimization Model (TLPOM) which exploits reasonable resource planning and common compiler optimization techniques to obtain the best blocks and threads configuration considering the resource constraints of each node. The key to this part is dynamic coupling Thread-Level Parallelism (TLP) and Instruction-Level Parallelism (ILP) to improve the performance of the algorithms without additional energy consumption. Finally, combining the ECCM and the TLPOM, we use the Reliable GPU Cluster Architecture (RGCA) to obtain a high-reliability computing system considering the nodes' diversity, algorithm characteristics, etc. The results show that the performance of the algorithms significantly increased by 34.1%, 33.96% and 24.07% for Fermi, Kepler and Maxwell on average with TLPOM and the RGCA ensures that our IoT computing system provides low-cost and high-reliability services.
de la Cámara, Miguel Ángel; Higueras-Fresnillo, Sara; Martinez-Gomez, David; Veiga, Oscar L
2018-05-29
The inter-day reliability of the Intelligent Device for Energy Expenditure and Activity (IDEEA) has not been studied to date. The study purpose was to examine the inter-day variability and reliability on two consecutive days collected with the IDEEA, as well as to predict the number of days needed to provide a reliable estimate of several movement (walking and climbing stairs) and non-movement behaviors (lying, reclining, sitting) and standing in older adults. The sample included 126 older adults (74 women) who wore the IDEEA for 48-h. Results showed low variability between the two days and its reliability was from moderate (ICC=0.34) to high (ICC=0.80) in most of movement and non-movement behaviors analyzed. The Bland-Altman plots showed a high-moderate agreement between days and the Spearman-Brown formula estimated ranged from 1.2 and 9.1 days of monitoring with the IDEEA are needed to achieve ICCs≥0.70 in older adults for sitting and climbing stairs, respectively.
NASA Technical Reports Server (NTRS)
Lin, Shu (Principal Investigator); Uehara, Gregory T.; Nakamura, Eric; Chu, Cecilia W. P.
1996-01-01
The (64, 40, 8) subcode of the third-order Reed-Muller (RM) code for high-speed satellite communications is proposed. The RM subcode can be used either alone or as an inner code of a concatenated coding system with the NASA standard (255, 233, 33) Reed-Solomon (RS) code as the outer code to achieve high performance (or low bit-error rate) with reduced decoding complexity. It can also be used as a component code in a multilevel bandwidth efficient coded modulation system to achieve reliable bandwidth efficient data transmission. The progress made toward achieving the goal of implementing a decoder system based upon this code is summarized. The development of the integrated circuit prototype sub-trellis IC, particularly focusing on the design methodology, is addressed.
Highly reliable high speed 1.1μm-InGaAs/GaAsP-VCSELs
NASA Astrophysics Data System (ADS)
Hatakeyama, H.; Anan, T.; Akagawa, T.; Fukatsu, K.; Suzuki, N.; Tokutome, K.; Tsuji, M.
2009-02-01
In this paper, we describe high temperature operation of high speed 1.1μm-range oxide-confined vertical-cavity surfaceemitting lasers (VCSELs) for optical interconnection applications. For achieving high speed of over 25 Gbit/s under a high temperature, we applied InGaAs/GaAsP strain-compensated multiple quantum wells (SC-MQWs) as the active layer. The developed device showed 25 Gbit/s error-free operation at 100°C. We also examined reliability of the VCSELs via accelerated life tests. The result showed extremely long MTTF lifetime of about 10 thousand hours under an ambient temperature of 150°C and a bias current of about 19 kA/cm2, a reliability that either equals or surpasses that of conventional 850-nm VCSELs with 10 Gbit/s. Moreover, we revealed a typical failure mode of the device; the result of analysis indicated that the failure was caused by <110> dark line defects (DLDs) generated in the n-DBR layers under the current aperture area.
Reliability of Fault Tolerant Control Systems. Part 2
NASA Technical Reports Server (NTRS)
Wu, N. Eva
2000-01-01
This paper reports Part II of a two part effort that is intended to delineate the relationship between reliability and fault tolerant control in a quantitative manner. Reliability properties peculiar to fault-tolerant control systems are emphasized, such as the presence of analytic redundancy in high proportion, the dependence of failures on control performance, and high risks associated with decisions in redundancy management due to multiple sources of uncertainties and sometimes large processing requirements. As a consequence, coverage of failures through redundancy management can be severely limited. The paper proposes to formulate the fault tolerant control problem as an optimization problem that maximizes coverage of failures through redundancy management. Coverage modeling is attempted in a way that captures its dependence on the control performance and on the diagnostic resolution. Under the proposed redundancy management policy, it is shown that an enhanced overall system reliability can be achieved with a control law of a superior robustness, with an estimator of a higher resolution, and with a control performance requirement of a lesser stringency.
Transferring Aviation Practices into Clinical Medicine for the Promotion of High Reliability.
Powell-Dunford, Nicole; McPherson, Mark K; Pina, Joseph S; Gaydos, Steven J
2017-05-01
Aviation is a classic example of a high reliability organization (HRO)-an organization in which catastrophic events are expected to occur without control measures. As health care systems transition toward high reliability, aviation practices are increasingly transferred for clinical implementation. A PubMed search using the terms aviation, crew resource management, and patient safety was undertaken. Manuscripts authored by physician pilots and accident investigation regulations were analyzed. Subject matter experts involved in adoption of aviation practices into the medical field were interviewed. A PubMed search yielded 621 results with 22 relevant for inclusion. Improved clinical outcomes were noted in five research trials in which aviation practices were adopted, particularly with regard to checklist usage and crew resource-management training. Effectiveness of interventions was influenced by intensity of application, leadership involvement, and provision of staff training. The usefulness of incorporating mishap investigation techniques has not been established. Whereas aviation accident investigation is highly standardized, the investigation of medical error is characterized by variation. The adoption of aviation practices into clinical medicine facilitates an evolution toward high reliability. Evidence for the efficacy of the checklist and crew resource-management training is robust. Transference of aviation accident investigation practices is preliminary. A standardized, independent investigation process could facilitate the development of a safety culture commensurate with that achieved in the aviation industry.Powell-Dunford N, McPherson MK, Pina JS, Gaydos SJ. Transferring aviation practices into clinical medicine for the promotion of high reliability. Aerosp Med Hum Perform. 2017; 88(5):487-491.
Crystalline-silicon reliability lessons for thin-film modules
NASA Technical Reports Server (NTRS)
Ross, R. G., Jr.
1985-01-01
The reliability of crystalline silicon modules has been brought to a high level with lifetimes approaching 20 years, and excellent industry credibility and user satisfaction. The transition from crystalline modules to thin film modules is comparable to the transition from discrete transistors to integrated circuits. New cell materials and monolithic structures will require new device processing techniques, but the package function and design will evolve to a lesser extent. Although there will be new encapsulants optimized to take advantage of the mechanical flexibility and low temperature processing features of thin films, the reliability and life degradation stresses and mechanisms will remain mostly unchanged. Key reliability technologies in common between crystalline and thin film modules include hot spot heating, galvanic and electrochemical corrosion, hail impact stresses, glass breakage, mechanical fatigue, photothermal degradation of encapsulants, operating temperature, moisture sorption, circuit design strategies, product safety issues, and the process required to achieve a reliable product from a laboratory prototype.
Approach to developing reliable space reactor power systems
NASA Technical Reports Server (NTRS)
Mondt, Jack F.; Shinbrot, Charles H.
1991-01-01
During Phase II, the Engineering Development Phase, the SP-100 Project has defined and is pursuing a new approach to developing reliable power systems. The approach to developing such a system during the early technology phase is described along with some preliminary examples to help explain the approach. Developing reliable components to meet space reactor power system requirements is based on a top-down systems approach which includes a point design based on a detailed technical specification of a 100-kW power system. The SP-100 system requirements implicitly recognize the challenge of achieving a high system reliability for a ten-year lifetime, while at the same time using technologies that require very significant development efforts. A low-cost method for assessing reliability, based on an understanding of fundamental failure mechanisms and design margins for specific failure mechanisms, is being developed as part of the SP-100 Program.
Fang, Zhiwei; Lin, Jintian; Wang, Min; Liu, Zhengming; Yao, Jinping; Qiao, Lingling; Cheng, Ya
2015-10-19
We demonstrate fabrication of a microtoroid resonator of a high-quality (high-Q) factor using femtosecond laser three-dimensional (3D) micromachining. A fiber taper is reliably assembled to the microtoroid using CO2 laser welding. Specifically, we achieve a high-Q-factor of 2.12 × 10(6) in the microresonator-fiber assembly by optimizing the contact position between the fiber taper and the microtoroid.
NASA Astrophysics Data System (ADS)
Hasegawa, N.; Koike, F.; Ikarashi, K.; Ishizone, M.; Kawamura, M.; Nakazawa, Y.; Takahashi, A.; Tomita, H.; Iwasaki, H.; Sahashi, M.
2002-05-01
To implement the specular nano-oxide-layer (NOL) spin valve (SV) heads for use in practical applications, it is key to simultaneously achieve a good specular effect of the NOL inserted in the synthetic ferrimagnet pinned layer (i.e., high magnetoresistance MR performance) and a strong pinning field through the NOL. By using CoFe+X as a substance to be subjected to oxidation, we obtained the NOL specular SV films simultaneously achieving a high MR ratio of 17%-18% and a high pinning field of 1100-1500 Oe. Narrow track (0.12 μm) heads were fabricated and they showed a high sensitivity of 10 mV/μm. Several reliability tests were done both at the sheet film level and the actual head level. The oxygen inside NOL was found to be stable up to 350 °C, and pinned layer magnetization canting after orthogonal field annealing was found to be almost the same as today's non-NOL SV films. An electrostatic discharge test and accelerated lifetime test were also performed and NOL specular heads were demonstrated to have almost the same robustness as today's non-NOL heads.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, Sisi; Nicely, Lucas D; Zhang, Haibin
Modern large-scale networks require the ability to withstand arbitrary failures (i.e., Byzantine failures). Byzantine reliable broadcast algorithms can be used to reliably disseminate information in the presence of Byzantine failures. We design a novel Byzantine reliable broadcast protocol for loosely connected and synchronous networks. While previous such protocols all assume correct senders, our protocol is the first to handle Byzantine senders. To achieve this goal, we have developed new techniques for fault detection and fault tolerance. Our protocol is efficient, and under normal circumstances, no expensive public-key cryptographic operations are used. We implement and evaluate our protocol, demonstrating that ourmore » protocol has high throughput and is superior to the existing protocols in uncivil executions.« less
Memorial Hermann: high reliability from board to bedside.
Shabot, M Michael; Monroe, Douglas; Inurria, Juan; Garbade, Debbi; France, Anne-Claire
2013-06-01
In 2006 the Memorial Hermann Health System (MHHS), which includes 12 hospitals, began applying principles embraced by high reliability organizations (HROs). Three factors support its HRO journey: (1) aligned organizational structure with transparent management systems and compressed reporting processes; (2) Robust Process Improvement (RPI) with high-reliability interventions; and (3) cultural establishment, sustainment, and evolution. The Quality and Safety strategic plan contains three domains, each with a specific set of measures that provide goals for performance: (1) "Clinical Excellence;" (2) "Do No Harm;" and (3) "Saving Lives," as measured by the Serious Safety Event rate. MHHS uses a uniform approach to performance improvement--RPI, which includes Six Sigma, Lean, and change management, to solve difficult safety and quality problems. The 9 acute care hospitals provide multiple opportunities to integrate high-reliability interventions and best practices across MHHS. For example, MHHS partnered with the Joint Commission Center for Transforming Healthcare in its inaugural project to establish reliable hand hygiene behaviors, which improved MHHS's average hand hygiene compliance rate from 44% to 92% currently. Soon after compliance exceeded 85% at all 12 hospitals, the average rate of central line-associated bloodstream and ventilator-associated pneumonias decreased to essentially zero. MHHS's size and diversity require a disciplined approach to performance improvement and systemwide achievement of measurable success. The most significant cultural change at MHHS has been the expectation for 100% compliance with evidence-based quality measures and 0% incidence of patient harm.
A new communication protocol family for a distributed spacecraft control system
NASA Technical Reports Server (NTRS)
Baldi, Andrea; Pace, Marco
1994-01-01
In this paper we describe the concepts behind and architecture of a communication protocol family, which was designed to fulfill the communication requirements of ESOC's new distributed spacecraft control system SCOS 2. A distributed spacecraft control system needs a data delivery subsystem to be used for telemetry (TLM) distribution, telecommand (TLC) dispatch and inter-application communication, characterized by the following properties: reliability, so that any operational workstation is guaranteed to receive the data it needs to accomplish its role; efficiency, so that the telemetry distribution, even for missions with high telemetry rates, does not cause a degradation of the overall control system performance; scalability, so that the network is not the bottleneck both in terms of bandwidth and reconfiguration; flexibility, so that it can be efficiently used in many different situations. The new protocol family which satisfies the above requirements is built on top of widely used communication protocols (UDP and TCP), provides reliable point-to-point and broadcast communication (UDP+) and is implemented in C++. Reliability is achieved using a retransmission mechanism based on a sequence numbering scheme. Such a scheme allows to have cost-effective performances compared to the traditional protocols, because retransmission is only triggered by applications which explicitly need reliability. This flexibility enables applications with different profiles to take advantage of the available protocols, so that the best rate between sped and reliability can be achieved case by case.
Testing Integrity Symposium: Issues and Recommendations for Best Practice
ERIC Educational Resources Information Center
National Center for Education Statistics, 2013
2013-01-01
Educators, parents, and the public depend on accurate, valid, reliable, and timely information about student academic performance. Testing irregularities--breaches of test security or improper administration of academic testing--undermine efforts to use those data to improve student achievement. Unfortunately, there have been high-profile and…
Ahern, Tracey; Gardner, Anne; Gardner, Glenn; Middleton, Sandy; Della, Phillip
2013-05-01
The final phase of a three phase study analysing the implementation and impact of the nurse practitioner role in Australia (the Australian Nurse Practitioner Project or AUSPRAC) was undertaken in 2009, requiring nurse telephone interviewers to gather information about health outcomes directly from patients and their treating nurse practitioners. A team of several registered nurses was recruited and trained as telephone interviewers. The aim of this paper is to report on development and evaluation of the training process for telephone interviewers. The training process involved planning the content and methods to be used in the training session; delivering the session; testing skills and understanding of interviewers post-training; collecting and analysing data to determine the degree to which the training process was successful in meeting objectives and post-training follow-up. All aspects of the training process were informed by established educational principles. Interrater reliability between interviewers was high for well-validated sections of the survey instrument resulting in 100% agreement between interviewers. Other sections with unvalidated questions showed lower agreement (between 75% and 90%). Overall the agreement between interviewers was 92%. Each interviewer was also measured against a specifically developed master script or gold standard and for this each interviewer achieved a percentage of correct answers of 94.7% or better. This equated to a Kappa value of 0.92 or better. The telephone interviewer training process was very effective and achieved high interrater reliability. We argue that the high reliability was due to the use of well validated instruments and the carefully planned programme based on established educational principles. There is limited published literature on how to successfully operationalise educational principles and tailor them for specific research studies; this report addresses this knowledge gap. Copyright © 2012 Elsevier Ltd. All rights reserved.
A novel redundant INS based on triple rotary inertial measurement units
NASA Astrophysics Data System (ADS)
Chen, Gang; Li, Kui; Wang, Wei; Li, Peng
2016-10-01
Accuracy and reliability are two key performances of inertial navigation system (INS). Rotation modulation (RM) can attenuate the bias of inertial sensors and make it possible for INS to achieve higher navigation accuracy with lower-class sensors. Therefore, the conflict between the accuracy and cost of INS can be eased. Traditional system redundancy and recently researched sensor redundancy are two primary means to improve the reliability of INS. However, how to make the best use of the redundant information from redundant sensors hasn’t been studied adequately, especially in rotational INS. This paper proposed a novel triple rotary unit strapdown inertial navigation system (TRUSINS), which combines RM and sensor redundancy design to enhance the accuracy and reliability of rotational INS. Each rotary unit independently rotates to modulate the errors of two gyros and two accelerometers. Three units can provide double sets of measurements along all three axes of body frame to constitute a couple of INSs which make TRUSINS redundant. Experiments and simulations based on a prototype which is made up of six fiber-optic gyros with drift stability of 0.05° h-1 show that TRUSINS can achieve positioning accuracy of about 0.256 n mile h-1, which is ten times better than that of a normal non-rotational INS with the same level inertial sensors. The theoretical analysis and the experimental results show that due to the advantage of the innovative structure, the designed fault detection and isolation (FDI) strategy can tolerate six sensor faults at most, and is proved to be effective and practical. Therefore, TRUSINS is particularly suitable and highly beneficial for the applications where high accuracy and high reliability is required.
The interplay between academic performance and quality of life among preclinical students.
Shareef, Mohammad Abrar; AlAmodi, Abdulhadi A; Al-Khateeb, Abdulrahman A; Abudan, Zainab; Alkhani, Mohammed A; Zebian, Sanderlla I; Qannita, Ahmed S; Tabrizi, Mariam J
2015-10-31
The high academic performance of medical students greatly influences their professional competence in long term career. Meanwhile, medical students greatly demand procuring a good quality of life that can help them sustain their medical career. This study examines validity and reliability of the tool among preclinical students and testifies the influence of their scholastic performance along with gender and academic year on their quality of life. A cross sectional study was conducted by distributing World Health Organization Quality of Life, WHOQOL-BREF, survey among medical students of year one to three at Alfaisal University. For validity, item discriminate validity(IDV) and confirmatory factor analysis were measured and for reliability, Cronbach's α test and internal item consistency(IIC) were examined. The association of GPA, gender and academic year with all major domains was drawn using Pearson's correlation, independent samples t-test and one-way ANOVA, respectively. A total of 335 preclinical students have responded to this questionnaire. The construct has demonstrated an adequate validity and good reliability. The high academic performance of students positively correlated with physical (r = 0.23, p < 0.001), psychological health (r = 0.29, p < 0.001), social relations (r = 0.11, p = 0.03) and environment (r = 0.23, p < 0.001). Male student scored higher than female peers in physical and psychological health. This study has identified a direct relationship between the academic performance of preclinical students and their quality of life. The WHOQOL-BREF is a valid and reliable tool among preclinical students and the positive direction of high academic performance with greater QOL suggests that academic achievers procure higher satisfaction and poor achievers need a special attention for the improvement of their quality of life.
NASA Technical Reports Server (NTRS)
Karns, James
1993-01-01
The objective of this study was to establish the initial quantitative reliability bounds for nuclear electric propulsion systems in a manned Mars mission required to ensure crew safety and mission success. Finding the reliability bounds involves balancing top-down (mission driven) requirements and bottom-up (technology driven) capabilities. In seeking this balance we hope to accomplish the following: (1) provide design insights into the achievability of the baseline design in terms of reliability requirements, given the existing technology base; (2) suggest alternative design approaches which might enhance reliability and crew safety; and (3) indicate what technology areas require significant research and development to achieve the reliability objectives.
Integrated Design Methodology for Highly Reliable Liquid Rocket Engine
NASA Astrophysics Data System (ADS)
Kuratani, Naoshi; Aoki, Hiroshi; Yasui, Masaaki; Kure, Hirotaka; Masuya, Goro
The Integrated Design Methodology is strongly required at the conceptual design phase to achieve the highly reliable space transportation systems, especially the propulsion systems, not only in Japan but also all over the world in these days. Because in the past some catastrophic failures caused some losses of mission and vehicle (LOM/LOV) at the operational phase, moreover did affect severely the schedule delays and cost overrun at the later development phase. Design methodology for highly reliable liquid rocket engine is being preliminarily established and investigated in this study. The sensitivity analysis is systematically performed to demonstrate the effectiveness of this methodology, and to clarify and especially to focus on the correlation between the combustion chamber, turbopump and main valve as main components. This study describes the essential issues to understand the stated correlations, the need to apply this methodology to the remaining critical failure modes in the whole engine system, and the perspective on the engine development in the future.
Novel High Integrity Bio-Inspired Systems with On-Line Self-Test and Self-Repair Properties
NASA Astrophysics Data System (ADS)
Samie, Mohammad; Dragffy, Gabriel; Pipe, Tony
2011-08-01
Since the beginning of life nature has been developing some remarkable solutions to the problem of creating reliable systems that can operate under difficult environmental and fault conditions. Yet, no matter how sophisticated our systems are, we are still unable to match the high degree of reliability that biological organisms posses. Since the early '90s attempts have been made to adapt biological properties and processes to the design of electronic systems but the results have always been unduly complex.This paper, proposes a novel model using a radically new approach to construct highly reliable electronic systems with online fault repair properties. It uses the characteristics and behaviour of unicellular bacteria and bacterial communities to achieve this. The result is a configurable bio-inspired cellular array architecture that, with built-in self-diagnostic and self-repair properties, can implement any application specific electronic system but is particularly suited for safety critical environments, such as space.
NASA Astrophysics Data System (ADS)
Tao, Ye; Ding, Wentao; Wang, Zhongqiang; Xu, Haiyang; Zhao, Xiaoning; Li, Xuhong; Liu, Weizhen; Ma, Jiangang; Liu, Yichun
2018-05-01
In this work, we demonstrated an effective method to improve the switching reliability of HfOx based RRAM device by inserting mountain-like surface-graphited carbon (MSGC) layer. The MSGC layer was fabricated through thermal annealing of amorphous carbon (a-C) film with high sp2 proportion (49.7%) under 500 °C on Pt substrate, whose characteristics were validated by XPS and Raman spectrums. The local electric-field (LEF) was enhanced around the nanoscale tips of MSGC layer due to large surface curvature, which leads to simplified CFs and localization of resistive switching region. It takes responsibility to the reduction of high/low resistance states (HRS/LRS) fluctuation from 173.8%/64.9% to 23.6%/6.5%, respectively. In addition, the resulting RRAM devices exhibited fast switching speed (<65 ns), good retention (>104 s at 85 °C) and low cycling degradation. This method could be promising to develop reliable and repeatable high-performance RRAM for practical applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodhouse, Michael; Jones-Albertus, Rebecca; Feldman, David
2016-05-01
This report examines the remaining challenges to achieving the competitive photovoltaic (PV) costs and large-scale deployment envisioned under the U.S. Department of Energy's SunShot Initiative. Solar-energy cost reductions can be realized through lower PV module and balance-of-system (BOS) costs as well as improved system efficiency and reliability. Numerous combinations of PV improvements could help achieve the levelized cost of electricity (LCOE) goals because of the tradeoffs among key metrics like module price, efficiency, and degradation rate as well as system price and lifetime. Using LCOE modeling based on bottom-up cost analysis, two specific pathways are mapped to exemplify the manymore » possible approaches to module cost reductions of 29%-38% between 2015 and 2020. BOS hardware and soft cost reductions, ranging from 54%-77% of total cost reductions, are also modeled. The residential sector's high supply-chain costs, labor requirements, and customer-acquisition costs give it the greatest BOS cost-reduction opportunities, followed by the commercial sector, although opportunities are available to the utility-scale sector as well. Finally, a future scenario is considered in which very high PV penetration requires additional costs to facilitate grid integration and increased power-system flexibility--which might necessitate even lower solar LCOEs. The analysis of a pathway to 3-5 cents/kWh PV systems underscores the importance of combining robust improvements in PV module and BOS costs as well as PV system efficiency and reliability if such aggressive long-term targets are to be achieved.« less
NASA Astrophysics Data System (ADS)
Wang, Chaoen; Chang, Lung-Hai; Chang, Mei-Hsia; Chen, Ling-Jhen; Chung, Fu-Tsai; Lin, Ming-Chyuan; Liu, Zong-Kai; Lo, Chih-Hung; Tsai, Chi-Lin; Yeh, Meng-Shu; Yu, Tsung-Chi
2017-11-01
Excitation of multipacting, enhanced by gas condensation on cold surfaces of the high power input coupler in a SRF module poses the highest challenge for reliable SRF operation under high average RF power. This could prevent the light source SRF module from being operated with a desired high beam current. Off-line long-term reliability tests have been conducted for the newly constructed 500-MHz SRF KEKB type modules at an accelerating RF voltage of 1.6-MV to enable prediction of their operational reliability in the 3-GeV Taiwan Photon Source (TPS), since prediction from mere production performance by conventional horizontal test is presently unreliable. As expected, operational difficulties resulting from multipacting, enhanced by gas condensation, have been identified in the course of long-term reliability test. Our present hypothesis is that gas condensation can be slowed down by preserving the vacuum pressure at the power coupler close to that reached just after its cool down to liquid helium temperatures. This is achievable by reduction of the power coupler out-gassing rate through comprehensive warm aging. Its feasibility and effectiveness has been experimentally verified in a second long term reliability test. Our success opens the possibility to operate the SRF module free of multipacting trouble and opens a new direction to improve the operational performance of next generation SRF modules in light sources with high beam currents.
Estimating the Reliability of Electronic Parts in High Radiation Fields
NASA Technical Reports Server (NTRS)
Everline, Chester; Clark, Karla; Man, Guy; Rasmussen, Robert; Johnston, Allan; Kohlhase, Charles; Paulos, Todd
2008-01-01
Radiation effects on materials and electronic parts constrain the lifetime of flight systems visiting Europa. Understanding mission lifetime limits is critical to the design and planning of such a mission. Therefore, the operational aspects of radiation dose are a mission success issue. To predict and manage mission lifetime in a high radiation environment, system engineers need capable tools to trade radiation design choices against system design and reliability, and science achievements. Conventional tools and approaches provided past missions with conservative designs without the ability to predict their lifetime beyond the baseline mission.This paper describes a more systematic approach to understanding spacecraft design margin, allowing better prediction of spacecraft lifetime. This is possible because of newly available electronic parts radiation effects statistics and an enhanced spacecraft system reliability methodology. This new approach can be used in conjunction with traditional approaches for mission design. This paper describes the fundamentals of the new methodology.
ERIC Educational Resources Information Center
Valen, Jakob; Ryum, Truls; Svartberg, Martin; Stiles, Tore C.; McCullough, Leigh
2011-01-01
This study examined interrater reliability and sensitivity to change of the Achievement of Therapeutic Objectives Scale (ATOS; McCullough, Larsen, et al., 2003) in short-term dynamic psychotherapy (STDP) and cognitive therapy (CT). The ATOS is a process scale originally developed to assess patients' achievements of treatment objectives in STDP,…
Advances in tunable diode laser technology
NASA Technical Reports Server (NTRS)
Lo, W.
1980-01-01
The improvement of long-term reliability, the purification of mode properties, and the achievement of higher-temperature operation were examined. In reliability studies a slow increase in contact resistance during room temperature storage for lasers fabricated with In-Au or In-Pt contacts was observed. This increase is actually caused by the diffusion of In into the surface layer of laser crystals. By using a three layered structure of In-Au-Pt or In-Pt-Au, this mode of degradation was reduced. In characterizing the mode properties, it was found that the lasers emit in a highly localized, filamentary manner. For widestripe lasers the emission occurs near the corners of the junction. In order to achieve single-mode operation, stripe widths on the order of 8-10 micrometers are needed. Also, it was found that room temperature electroluminescence is possible near 4.6 micrometers.
Reliability in perceptual analysis of voice quality.
Bele, Irene Velsvik
2005-12-01
This study focuses on speaking voice quality in male teachers (n = 35) and male actors (n = 36), who represent untrained and trained voice users, because we wanted to investigate normal and supranormal voices. In this study, both substantial and methodologic aspects were considered. It includes a method for perceptual voice evaluation, and a basic issue was rater reliability. A listening group of 10 listeners, 7 experienced speech-language therapists, and 3 speech-language therapist students evaluated the voices by 15 vocal characteristics using VA scales. Two sets of voice signals were investigated: text reading (2 loudness levels) and sustained vowel (3 levels). The results indicated a high interrater reliability for most perceptual characteristics. Connected speech was evaluated more reliably, especially at the normal level, but both types of voice signals were evaluated reliably, although the reliability for connected speech was somewhat higher than for vowels. Experienced listeners tended to be more consistent in their ratings than did the student raters. Some vocal characteristics achieved acceptable reliability even with a smaller panel of listeners. The perceptual characteristics grouped in 4 factors reflected perceptual dimensions.
Mindful Organizing as a Paradigm to Develop Managers
ERIC Educational Resources Information Center
Gebauer, Annette
2013-01-01
How can managers prepare for extreme but exceptional events and for the challenge of managing complexity and uncertainty in their daily business? Confronted with the challenge of achieving high and reliable performance in risk-prone, fast-paced, and unpredictable environments, managers and management scholars can learn a lot from the organizing…
Highly Efficient and Reliable Transparent Electromagnetic Interference Shielding Film.
Jia, Li-Chuan; Yan, Ding-Xiang; Liu, Xiaofeng; Ma, Rujun; Wu, Hong-Yuan; Li, Zhong-Ming
2018-04-11
Electromagnetic protection in optoelectronic instruments such as optical windows and electronic displays is challenging because of the essential requirements of a high optical transmittance and an electromagnetic interference (EMI) shielding effectiveness (SE). Herein, we demonstrate the creation of an efficient transparent EMI shielding film that is composed of calcium alginate (CA), silver nanowires (AgNWs), and polyurethane (PU), via a facile and low-cost Mayer-rod coating method. The CA/AgNW/PU film with a high optical transmittance of 92% achieves an EMI SE of 20.7 dB, which meets the requirements for commercial shielding applications. A superior EMI SE of 31.3 dB could be achieved, whereas the transparent film still maintains a transmittance of 81%. The integrated efficient EMI SE and high transmittance are superior to those of most previously reported transparent EMI shielding materials. Moreover, our transparent films exhibit a highly reliable shielding ability in a complex service environment, with 98 and 96% EMI SE retentions even after 30 min of ultrasound treatment and 5000 bending cycles (1.5 mm radius), respectively. The comprehensive performance that is associated with the facile fabrication strategy imparts the CA/AgNW/PU film with great potential as an optimized EMI shielding material in emerging optoelectronic devices, such as flexible solar cells, displays, and touch panels.
Early study on the application of Nexcera ultra low thermal expansion ceramic to space telescopes
NASA Astrophysics Data System (ADS)
Kamiya, Tomohiro; Sugawara, Jun; Mizutani, Tadahito; Yasuda, Susumu; Kitamoto, Kazuya
2017-09-01
Optical mirrors for space telescopes, which require high precision and high thermal stability, have commonly been made of glass materials such as ultra low expansion glass (e.g. ULE®) or extremely low expansion glassceramic (e.g. ZERODUR® or CLEARCERAM®). These materials have been well-known for their reliability due to their long history of achievements in many space applications.
ERIC Educational Resources Information Center
Wray, Kraig; Lai, Cheng-Fei; Sáez, Leilani; Alonzo, Julie; Tindal, Gerald
2013-01-01
We report the results of an alternate form reliability and criterion validity study of kindergarten and grade 1 (N = 84-199) reading measures from the easyCBM© assessment system and Stanford Early School Achievement Test/Stanford Achievement Test, 10th edition (SESAT/SAT-10) across 5 time points. The alternate form reliabilities ranged from…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurt Beran; John Christenson; Dragos Nica
2002-12-15
The goal of the project is to enable plant operators to detect with high sensitivity and reliability the onset of decalibration drifts in all of the instrumentation used as input to the reactor heat balance calculations. To achieve this objective, the collaborators developed and implemented at DBNPS an extension of the Multivariate State Estimation Technique (MSET) pattern recognition methodology pioneered by ANAL. The extension was implemented during the second phase of the project and fully achieved the project goal.
Huang, Yifeng; Deng, Zexiang; Wang, Weiliang; Liang, Chaolun; She, Juncong; Deng, Shaozhi; Xu, Ningsheng
2015-01-01
Nano-scale vacuum channel transistors possess merits of higher cutoff frequency and greater gain power as compared with the conventional solid-state transistors. The improvement in cathode reliability is one of the major challenges to obtain high performance vacuum channel transistors. We report the experimental findings and the physical insight into the field induced crystalline-to-amorphous phase transformation on the surface of the Si nano-cathode. The crystalline Si tip apex deformed to amorphous structure at a low macroscopic field (0.6~1.65 V/nm) with an ultra-low emission current (1~10 pA). First-principle calculation suggests that the strong electrostatic force exerting on the electrons in the surface lattices would take the account for the field-induced atomic migration that result in an amorphization. The arsenic-dopant in the Si surface lattice would increase the inner stress as well as the electron density, leading to a lower amorphization field. Highly reliable Si nano-cathodes were obtained by employing diamond like carbon coating to enhance the electron emission and thus decrease the surface charge accumulation. The findings are crucial for developing highly reliable Si-based nano-scale vacuum channel transistors and have the significance for future Si nano-electronic devices with narrow separation. PMID:25994377
Validity and reliability assessment of a peer evaluation method in team-based learning classes.
Yoon, Hyun Bae; Park, Wan Beom; Myung, Sun-Jung; Moon, Sang Hui; Park, Jun-Bean
2018-03-01
Team-based learning (TBL) is increasingly employed in medical education because of its potential to promote active group learning. In TBL, learners are usually asked to assess the contributions of peers within their group to ensure accountability. The purpose of this study is to assess the validity and reliability of a peer evaluation instrument that was used in TBL classes in a single medical school. A total of 141 students were divided into 18 groups in 11 TBL classes. The students were asked to evaluate their peers in the group based on evaluation criteria that were provided to them. We analyzed the comments that were written for the highest and lowest achievers to assess the validity of the peer evaluation instrument. The reliability of the instrument was assessed by examining the agreement among peer ratings within each group of students via intraclass correlation coefficient (ICC) analysis. Most of the students provided reasonable and understandable comments for the high and low achievers within their group, and most of those comments were compatible with the evaluation criteria. The average ICC of each group ranged from 0.390 to 0.863, and the overall average was 0.659. There was no significant difference in inter-rater reliability according to the number of members in the group or the timing of the evaluation within the course. The peer evaluation instrument that was used in the TBL classes was valid and reliable. Providing evaluation criteria and rules seemed to improve the validity and reliability of the instrument.
Reliability Impacts in Life Support Architecture and Technology Selection
NASA Technical Reports Server (NTRS)
Lange, Kevin E.; Anderson, Molly S.
2011-01-01
Equivalent System Mass (ESM) and reliability estimates were performed for different life support architectures based primarily on International Space Station (ISS) technologies. The analysis was applied to a hypothetical 1-year deep-space mission. High-level fault trees were initially developed relating loss of life support functionality to the Loss of Crew (LOC) top event. System reliability was then expressed as the complement (nonoccurrence) this event and was increased through the addition of redundancy and spares, which added to the ESM. The reliability analysis assumed constant failure rates and used current projected values of the Mean Time Between Failures (MTBF) from an ISS database where available. Results were obtained showing the dependence of ESM on system reliability for each architecture. Although the analysis employed numerous simplifications and many of the input parameters are considered to have high uncertainty, the results strongly suggest that achieving necessary reliabilities for deep-space missions will add substantially to the life support system mass. As a point of reference, the reliability for a single-string architecture using the most regenerative combination of ISS technologies without unscheduled replacement spares was estimated to be less than 1%. The results also demonstrate how adding technologies in a serial manner to increase system closure forces the reliability of other life support technologies to increase in order to meet the system reliability requirement. This increase in reliability results in increased mass for multiple technologies through the need for additional spares. Alternative parallel architecture approaches and approaches with the potential to do more with less are discussed. The tall poles in life support ESM are also reexamined in light of estimated reliability impacts.
A cost assessment of reliability requirements for shuttle-recoverable experiments
NASA Technical Reports Server (NTRS)
Campbell, J. W.
1975-01-01
The relaunching of unsuccessful experiments or satellites will become a real option with the advent of the space shuttle. An examination was made of the cost effectiveness of relaxing reliability requirements for experiment hardware by allowing more than one flight of an experiment in the event of its failure. Any desired overall reliability or probability of mission success can be acquired by launching an experiment with less reliability two or more times if necessary. Although this procedure leads to uncertainty in total cost projections, because the number of flights is not known in advance, a considerable cost reduction can sometimes be achieved. In cases where reflight costs are low relative to the experiment's cost, three flights with overall reliability 0.9 can be made for less than half the cost of one flight with a reliability of 0.9. An example typical of shuttle payload cost projections is cited where three low reliability flights would cost less than $50 million and a single high reliability flight would cost over $100 million. The ratio of reflight cost to experiment cost is varied and its effect on the range in total cost is observed. An optimum design reliability selection criterion to minimize expected cost is proposed, and a simple graphical method of determining this reliability is demonstrated.
Special Issue on a Fault Tolerant Network on Chip Architecture
NASA Astrophysics Data System (ADS)
Janidarmian, Majid; Tinati, Melika; Khademzadeh, Ahmad; Ghavibazou, Maryam; Fekr, Atena Roshan
2010-06-01
In this paper a fast and efficient spare switch selection algorithm is presented in a reliable NoC architecture based on specific application mapped onto mesh topology called FERNA. Based on ring concept used in FERNA, this algorithm achieves best results equivalent to exhaustive algorithm with much less run time improving two parameters. Inputs of FERNA algorithm for response time of the system and extra communication cost minimization are derived from simulation of high transaction level using SystemC TLM and mathematical formulation, respectively. The results demonstrate that improvement of above mentioned parameters lead to advance whole system reliability that is analytically calculated. Mapping algorithm has been also investigated as an effective issue on extra bandwidth requirement and system reliability.
Helicobacter pylori therapy: a paradigm shift
Graham, David Y; Dore, Maria Pina
2016-01-01
SUMMARY Helicobacter pylori (H. Pylori) is a leading cause of gastroduodenal disease, including gastric cancer. H. pylori eradication therapies and their efficacy are summarized. A number of current treatment regimens will reliably yield >90% or 95% cure rates with susceptible strains. None has proven to be superior. We show how to predict the efficacy of a regimen in any population provided one knows the prevalence of antibiotic resistance. As with other infectious diseases, therapy should always be susceptibility-based. Susceptibility testing should be demanded. We provide recommendations for empiric therapies when the only option and describe how to distinguish studies providing misinformation from those providing reliable and interpretable data. When treated as an infectious disease, high H. pylori cure rates are relatively simple to reliably achieve. PMID:27077447
Concept Demonstration of Dopant Selective Reactive Etching (DSRIE) in Silicon Carbide
NASA Technical Reports Server (NTRS)
Okojie, Robert S.
2015-01-01
Accurate quantification of combustor pressure dynamics for the primary purpose of experimental validation of computational fluid dynamics (CFD) codes requires the use of robust, reliable and sensitive pressure sensors that can resolve sub--pound-per-square-inch pressure levels in high temperature environments (i.e., combustor). The state of the art microfabricated piezoresistive silicon carbide (SiC) pressure sensors that we have developed are capable of operating reliably at 600 degrees Centigrade. This technology was used in support of the ARMD ISRP-ERA (NASA's Aeronautics Research Mission Directorate, Integrated System Research Project - Environmentally Responsible Aviation) program to quantify combustor thermoacoustic instabilities. The results showed that while the SiC pressure sensors survived the high temperature and measured instabilities, the diaphragm (force collector) was not thin enough to be sensitive in resolving sub-pound-per-square-inch pressures; 30 meters is the thinnest diaphragm achievable with conventional reactive ion etching (RIE) processes. Therefore, this precludes its use for sub-pound-per-square-inch pressure measurement with high fidelity. In order to effectively resolve sub-pound-per-square-inch pressures, a thinner more sensitive diaphragm (10 meters) is needed. To achieve this would require a new and innovative fabrication process technique.
Phase-I investigation of high-efficiency power amplifiers for 325 and 650 MHz
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raab, Frederick
2018-01-27
This Phase-I SBIR grant investigated techniques for high-efficiency power amplification for DoE particle accelerators such as Project X that operate at 325 and 650 MHz. The recommended system achieves high efficiency, high reliability, and hot-swap capability by integrating class-F power amplifiers, class-S modulators, power combiners, and a digital signal processor. Experimental evaluations demonstrate the production of 120 W per transistor with overall efficiencies from 86 percent at 325 MHz and 80 percent at 650 MHz.
DPSSL and FL pumps based on 980-nm telecom pump laser technology: changing the industry
NASA Astrophysics Data System (ADS)
Lichtenstein, Norbert; Schmidt, Berthold E.; Fily, Arnaud; Weiss, Stefan; Arlt, Sebastian; Pawlik, Susanne; Sverdlov, Boris; Muller, Jurgen; Harder, Christoph S.
2004-06-01
Diode-pumped solid state laser (DPSSL) and fiber laser (FL) are believed to become the dominant systems of very high power lasers in the industrial environment. Today, ranging from 100 W to 5 - 10 kW in light output power, their field of applications spread from biomedical and sensoring to material processing. Key driver for the wide spread of such systems is a competitive ratio of cost, performance and reliability. Enabling high power, highly reliable broad-area laser diodes and laser diode bars with excellent performance at the relevant wavelengths can further optimize this ratio. In this communication we present, that this can be achieved by leveraging the tremendous improvements in reliability and performance together with the high volume, low cost manufacturing areas established during the "telecom-bubble." From today's generations of 980-nm narrow-stripe laser diodes 1.8 W of maximum CW output power can be obtained fulfilling the stringent telecom reliability at operating conditions. Single-emitter broad-area lasers deliver in excess of 11 W CW while from similar 940-nm laser bars more than 160 W output power (CW) can be obtained at 200 A. In addition, introducing telecom-grade AuSn-solder mounting technology on expansion matched subassemblies enables excellent reliability performance. Degradation rates of less than 1% over 1000 h at 60 A are observed for both 808-nm and 940-nm laser bars even under harsh intermittent operation conditions.
Space Shuttle Main Engine - The Relentless Pursuit of Improvement
NASA Technical Reports Server (NTRS)
VanHooser, Katherine P.; Bradley, Douglas P.
2011-01-01
The Space Shuttle Main Engine (SSME) is the only reusable large liquid rocket engine ever developed. The specific impulse delivered by the staged combustion cycle, substantially higher than previous rocket engines, minimized volume and weight for the integrated vehicle. The dual pre-burner configuration permitted precise mixture ratio and thrust control while the fully redundant controller and avionics provided a very high degree of system reliability and health diagnosis. The main engine controller design was the first rocket engine application to incorporate digital processing. The engine was required to operate at a high chamber pressure to minimize engine volume and weight. Power level throttling was required to minimize structural loads on the vehicle early in flight and acceleration levels on the crew late in ascent. Fatigue capability, strength, ease of assembly and disassembly, inspectability, and materials compatibility were all major considerations in achieving a fully reusable design. During the multi-decade program the design evolved substantially using a series of block upgrades. A number of materials and manufacturing challenges were encountered throughout SSME s history. Significant development was required for the final configuration of the high pressure turbopumps. Fracture control was implemented to assess life limits of critical materials and components. Survival in the hydrogen environment required assessment of hydrogen embrittlement. Instrumentation systems were a challenge due to the harsh thermal and dynamic environments within the engine. Extensive inspection procedures were developed to assess the engine components between flights. The Space Shuttle Main Engine achieved a remarkable flight performance record. All flights were successful with only one mission requiring an ascent abort condition, which still resulted in an acceptable orbit and mission. This was achieved in large part via extensive ground testing to fully characterize performance and to establish acceptable life limits. During the program over a million seconds of accumulated test and flight time was achieved. Post flight inspection and assessment was a key part of assuring proper performance of the flight hardware. By the end of the program the predicted reliability had improved by a factor of four. These unique challenges, evolution of the design, and the resulting reliability will be discussed in this paper.
Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akerstedt, Henrik; Muschter, Steffen; Drake, Gary
The Tile Calorimeter at ATLAS [1] is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links,more » will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new readout system will be installed in one slice of the ATLAS Tile Calorimeter. This will allow the proposed upgrade to be thoroughly evaluated well before the planned 2023 deployment in all slices, especially with regard to long term reliability. Different firmware strategies alongside with their integration in the demonstrator are presented in the context of high reliability protection against hardware malfunction and radiation induced errors.« less
Complementary Reliability-Based Decodings of Binary Linear Block Codes
NASA Technical Reports Server (NTRS)
Fossorier, Marc P. C.; Lin, Shu
1997-01-01
This correspondence presents a hybrid reliability-based decoding algorithm which combines the reprocessing method based on the most reliable basis and a generalized Chase-type algebraic decoder based on the least reliable positions. It is shown that reprocessing with a simple additional algebraic decoding effort achieves significant coding gain. For long codes, the order of reprocessing required to achieve asymptotic optimum error performance is reduced by approximately 1/3. This significantly reduces the computational complexity, especially for long codes. Also, a more efficient criterion for stopping the decoding process is derived based on the knowledge of the algebraic decoding solution.
Elsebaie, H B; Dannawi, Z; Altaf, F; Zaidan, A; Al Mukhtar, M; Shaw, M J; Gibson, A; Noordeen, H
2016-02-01
The achievement of shoulder balance is an important measure of successful scoliosis surgery. No previously described classification system has taken shoulder balance into account. We propose a simple classification system for AIS based on two components which include the curve type and shoulder level. Altogether, three curve types have been defined according to the size and location of the curves, each curve pattern is subdivided into type A or B depending on the shoulder level. This classification was tested for interobserver reproducibility and intraobserver reliability. A retrospective analysis of the radiographs of 232 consecutive cases of AIS patients treated surgically between 2005 and 2009 was also performed. Three major types and six subtypes were identified. Type I accounted for 30 %, type II 28 % and type III 42 %. The retrospective analysis showed three patients developed a decompensation that required extension of the fusion. One case developed worsening of shoulder balance requiring further surgery. This classification was tested for interobserver and intraobserver reliability. The mean kappa coefficients for interobserver reproducibility ranged from 0.89 to 0.952, while the mean kappa value for intraobserver reliability was 0.964 indicating a good-to-excellent reliability. The treatment algorithm guides the spinal surgeon to achieve optimal curve correction and postoperative shoulder balance whilst fusing the smallest number of spinal segments. The high interobserver reproducibility and intraobserver reliability makes it an invaluable tool to describe scoliosis curves in everyday clinical practice.
Fundamentals of Free-Space Optical Communications
NASA Technical Reports Server (NTRS)
Dolinar, Sam; Moision, Bruce; Erkmen, Baris
2012-01-01
Free-space optical communication systems potentially gain many dBs over RF systems. There is no upper limit on the theoretically achievable photon efficiency when the system is quantum-noise-limited: a) Intensity modulations plus photon counting can achieve arbitrarily high photon efficiency, but with sub-optimal spectral efficiency. b) Quantum-ideal number states can achieve the ultimate capacity in the limit of perfect transmissivity. Appropriate error correction codes are needed to communicate reliably near the capacity limits. Poisson-modeled noises, detector losses, and atmospheric effects must all be accounted for: a) Theoretical models are used to analyze performance degradations. b) Mitigation strategies derived from this analysis are applied to minimize these degradations.
A Note on the Incremental Validity of Aggregate Predictors.
ERIC Educational Resources Information Center
Day, H. D.; Marshall, David
Three computer simulations were conducted to show that very high aggregate predictive validity coefficients can occur when the across-case variability in absolute score stability occurring in both the predictor and criterion matrices is quite small. In light of the increase in internal consistency reliability achieved by the method of aggregation…
ERIC Educational Resources Information Center
Leaseburg, Melinda G.; And Others
This paper describes the development and test of an early-warning instrument for identifying at-risk students aged 10-15. A statistically sound test to identify at-risk high school students existed in the Personal Skills Map--Adolescent version (PSMA-A). This study used a modified version of PSM-A , which was renamed Personal Skills for…
Developmental Considerations on the Free-Piston Stirling Power Convertor for Use in Space
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2006-01-01
Free-piston Stirling power conversion has been considered a candidate for radioisotope power systems for space for more than a decade. Prior to the free-piston Stirling architecture, systems were designed with kinematic Stirling engines with rotary alternators to convert heat to electricity. These systems were proposed with lightly loaded linkages to achieve the necessary life. When the free-piston configuration was initially proposed, it was thought to be attractive due to the relatively high conversion efficiency, acceptable mass, and the potential for long life and high reliability. These features have consistently been recognized by teams that have studied technology options for radioisotope power systems. Since free-piston Stirling power conversion was first considered for space power applications, there have been major advances in three general areas of development: demonstration of life and reliability, the success achieved by Stirling cryocoolers in flight, and the overall developmental maturity of the technology for both flight and terrestrial applications. Based on these advances, free-piston Stirling convertors are currently being developed for a number of terrestrial applications. They commonly operate with the power, efficiency, life, and reliability as intended, and much of the development now centers on system integration. This paper will summarize the accomplishments of free-piston Stirling power conversion technology over the past decade, review the status, and discuss the challenges that remain.
Developmental Considerations on the Free-piston Stirling Power Convertor for Use in Space
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2007-01-01
Free-piston Stirling power conversion has been considered a candidate for radioisotope power systems for space for more than a decade. Prior to the free-piston Stirling architecture, systems were designed with kinematic Stirling engines with rotary alternators to convert heat to electricity. These systems were proposed with lightly loaded linkages to achieve the necessary life. When the free-piston configuration was initially proposed, it was thought to be attractive due to the relatively high conversion efficiency, acceptable mass, and the potential for long life and high reliability. These features have consistently been recognized by teams that have studied technology options for radioisotope power systems. Since free-piston Stirling power conversion was first considered for space power applications, there have been major advances in three general areas of development: demonstration of life and reliability, the success achieved by Stirling cryocoolers in flight, and the overall developmental maturity of the technology for both flight and terrestrial applications. Based on these advances, free-piston Stirling convertors are currently being developed for a number of terrestrial applications. They commonly operate with the power, efficiency, life, and reliability as intended, and much of the development now centers on system integration. This paper will summarize the accomplishments of free-piston Stirling power conversion technology over the past decade, review the status, and discuss the challenges that remain.
A History of Welding on the Space Shuttle Main Engine (1975 to 2010)
NASA Technical Reports Server (NTRS)
Zimmerman, Frank R.; Russell, Carolyn K.
2010-01-01
The Space Shuttle Main Engine (SSME) is a high performance, throttleable, liquid hydrogen fueled rocket engine. High thrust and specific impulse (Isp) are achieved through a staged combustion engine cycle, combined with high combustion pressure (approx.3000psi) generated by the two-stage pump and combustion process. The SSME is continuously throttleable from 67% to 109% of design thrust level. The design criteria for this engine maximize performance and weight, resulting in a 7,800 pound rocket engine that produces over a half million pounds of thrust in vacuum with a specific impulse of 452/sec. It is the most reliable rocket engine in the world, accumulating over one million seconds of hot-fire time and achieving 100% flight success in the Space Shuttle program. A rocket engine with the unique combination of high reliability, performance, and reusability comes at the expense of manufacturing simplicity. Several innovative design features and fabrication techniques are unique to this engine. This is as true for welding as any other manufacturing process. For many of the weld joints it seemed mean cheating physics and metallurgy to meet the requirements. This paper will present a history of the welding used to produce the world s highest performance throttleable rocket engine.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Woodhouse, Michael; Jones-Albertus, Rebecca; Feldman, David
2016-05-01
Although tremendous progress has been made in reducing the cost of PV systems, additional LCOE reductions of 40%–50% between 2015 and 2020 will be required to reach the SunShot Initiative’s targets (see Woodhouse et al. 2016). Understanding the tradeoffs between installed prices and other PV system characteristics—such as module efficiency, module degradation rate, and system lifetime—are vital. For example, with 29%-efficient modules and high reliability (a 50-year lifetime and a 0.2%/year module degradation rate), a residential PV system could achieve the SunShot LCOE goal with modules priced at almost $1.20/W. But change the lifetime to 10 years and the degradationmore » rate to 2%/year, and the system would need those very high-efficiency modules at zero cost to achieve the same LCOE. Although these examples are extreme, they serve to illustrate the wide range of technological combinations that could help drive PV toward the LCOE goals. SunShot’s PV roadmaps illustrate specific potential pathways to the target cost reductions.« less
Su, Fei; Wang, Jiang; Deng, Bin; Wei, Xi-Le; Chen, Ying-Yuan; Liu, Chen; Li, Hui-Yan
2015-02-01
The objective here is to explore the use of adaptive input-output feedback linearization method to achieve an improved deep brain stimulation (DBS) algorithm for closed-loop control of Parkinson's state. The control law is based on a highly nonlinear computational model of Parkinson's disease (PD) with unknown parameters. The restoration of thalamic relay reliability is formulated as the desired outcome of the adaptive control methodology, and the DBS waveform is the control input. The control input is adjusted in real time according to estimates of unknown parameters as well as the feedback signal. Simulation results show that the proposed adaptive control algorithm succeeds in restoring the relay reliability of the thalamus, and at the same time achieves accurate estimation of unknown parameters. Our findings point to the potential value of adaptive control approach that could be used to regulate DBS waveform in more effective treatment of PD.
Jeong, Jong Seok; Mkhoyan, K Andre
2016-06-01
Acquiring an atomic-resolution compositional map of crystalline specimens has become routine practice, thus opening possibilities for extracting subatomic information from such maps. A key challenge for achieving subatomic precision is the improvement of signal-to-noise ratio (SNR) of compositional maps. Here, we report a simple and reliable solution for achieving high-SNR energy-dispersive X-ray (EDX) spectroscopy spectrum images for individual atomic columns. The method is based on standard cross-correlation aided by averaging of single-column EDX maps with modifications in the reference image. It produces EDX maps with minimal specimen drift, beam drift, and scan distortions. Step-by-step procedures to determine a self-consistent reference map with a discussion on the reliability, stability, and limitations of the method are presented here.
Schoolbook Texts: Behavioral Achievement Priming in Math and Language.
Engeser, Stefan; Baumann, Nicola; Baum, Ingrid
2016-01-01
Prior research found reliable and considerably strong effects of semantic achievement primes on subsequent performance. In order to simulate a more natural priming condition to better understand the practical relevance of semantic achievement priming effects, running texts of schoolbook excerpts with and without achievement primes were used as priming stimuli. Additionally, we manipulated the achievement context; some subjects received no feedback about their achievement and others received feedback according to a social or individual reference norm. As expected, we found a reliable (albeit small) positive behavioral priming effect of semantic achievement primes on achievement in math (Experiment 1) and language tasks (Experiment 2). Feedback moderated the behavioral priming effect less consistently than we expected. The implication that achievement primes in schoolbooks can foster performance is discussed along with general theoretical implications.
Schoolbook Texts: Behavioral Achievement Priming in Math and Language
Engeser, Stefan; Baumann, Nicola; Baum, Ingrid
2016-01-01
Prior research found reliable and considerably strong effects of semantic achievement primes on subsequent performance. In order to simulate a more natural priming condition to better understand the practical relevance of semantic achievement priming effects, running texts of schoolbook excerpts with and without achievement primes were used as priming stimuli. Additionally, we manipulated the achievement context; some subjects received no feedback about their achievement and others received feedback according to a social or individual reference norm. As expected, we found a reliable (albeit small) positive behavioral priming effect of semantic achievement primes on achievement in math (Experiment 1) and language tasks (Experiment 2). Feedback moderated the behavioral priming effect less consistently than we expected. The implication that achievement primes in schoolbooks can foster performance is discussed along with general theoretical implications. PMID:26938446
Electrical insulation design requirements and reliability goals
NASA Astrophysics Data System (ADS)
Ross, R. G., Jr.
1983-11-01
The solar cells in a photovoltaic module which must be electrically isolated from module exterior surfaces to satisfy a variety of safety and operating considerations are discussed. The performance and reliability of the insulation system are examined. Technical requirements involve the capability of withstanding the differential voltage from the solar cells to the module frame. The maximum system voltage includes consideration of maximum open circuit array voltages achieved under low-temperature, high-irradiance conditions, and transient overvoltages due to system feedback of lightning transients. The latter is bounded by the characteristics of incorporated voltage limiting devices such as MOVs.
Fast gas spectroscopy using pulsed quantum cascade lasers
NASA Astrophysics Data System (ADS)
Beyer, T.; Braun, M.; Lambrecht, A.
2003-03-01
Laser spectroscopy has found many industrial applications, e.g., control of automotive exhaust and process monitoring. The midinfrared region is of special interest because it has stronger absorption lines compared to the near infrared (NIR). However, in the NIR high quality reliable laser sources, detectors, and passive optical components are available. A quantum cascade laser could change this situation if fundamental advantages can be exploited with compact and reliable systems. It will be shown that, using pulsed lasers and available fast detectors, lower residual sensitivity levels than in corresponding NIR systems can be achieved. The stability is sufficient for industrial applications.
NASA Technical Reports Server (NTRS)
Gerchar, Tim
1994-01-01
On the surface MAMMOTH is a high performance 5.25-inch half-high 8mm helical scan tape drive that records a native 20 Gigabytes of data on Advanced Metal Evaporated media at a sustained throughput of 3 Megabyte per second over a high speed SCSI interface, that is scheduled for production in the second half of 1995. But it's much more than that. Inside its custom designed sheet metal enclosure lies one of the greatest technical achievements of its kind. Exabyte's strategic direction is to increase throughput and capacity while continuing to improve drive, data and media reliability to its products. MAMMOTH adheres to that direction and the description of its technical advances is described in this paper. MAMMOTH can be broken down into four main functional assemblies: high-performance integrated digital electronics, high-reliability tape transport mechanism, high-performance scanner, and advanced metal evaporated media. All this technology is packaged into a standard 5.25-inch half-high form factor that dissipates only 15 watts.
Scheduling for energy and reliability management on multiprocessor real-time systems
NASA Astrophysics Data System (ADS)
Qi, Xuan
Scheduling algorithms for multiprocessor real-time systems have been studied for years with many well-recognized algorithms proposed. However, it is still an evolving research area and many problems remain open due to their intrinsic complexities. With the emergence of multicore processors, it is necessary to re-investigate the scheduling problems and design/develop efficient algorithms for better system utilization, low scheduling overhead, high energy efficiency, and better system reliability. Focusing cluster schedulings with optimal global schedulers, we study the utilization bound and scheduling overhead for a class of cluster-optimal schedulers. Then, taking energy/power consumption into consideration, we developed energy-efficient scheduling algorithms for real-time systems, especially for the proliferating embedded systems with limited energy budget. As the commonly deployed energy-saving technique (e.g. dynamic voltage frequency scaling (DVFS)) will significantly affect system reliability, we study schedulers that have intelligent mechanisms to recuperate system reliability to satisfy the quality assurance requirements. Extensive simulation is conducted to evaluate the performance of the proposed algorithms on reduction of scheduling overhead, energy saving, and reliability improvement. The simulation results show that the proposed reliability-aware power management schemes could preserve the system reliability while still achieving substantial energy saving.
NASA Astrophysics Data System (ADS)
Chung, Wan-Ho; Kim, Sang-Ho; Kim, Hak-Sung
2016-08-01
In this work, silver nanowire inks with hydroxypropyl methylcellulose (HPMC) binders were coated on polyethylene terephthalate (PET) substrates and welded via flash white light and ultraviolet C (UV-C) irradiation to produce highly conductive transparent electrodes. The coated silver nanowire films were firmly welded and embedded into PET substrate successfully at room temperature and under ambient conditions using an in-house flash white light welding system and UV-C irradiation. The effects of light irradiation conditions (light energy, irradiation time, pulse duration, and pulse number) on the silver nanowire networks were studied and optimized. Bending fatigue tests were also conducted to characterize the reliability of the welded transparent conductive silver nanowire films. The surfaces of the welded silver nanowire films were analyzed via scanning electron microscopy (SEM), while the transmittance of the structures was measured using a spectrophotometer. From the results, a highly conductive and transparent silver nanowire film with excellent reliability could be achieved at room temperature under ambient conditions via the combined flash white light and UV-C irradiation welding process.
Chung, Wan-Ho; Kim, Sang-Ho; Kim, Hak-Sung
2016-01-01
In this work, silver nanowire inks with hydroxypropyl methylcellulose (HPMC) binders were coated on polyethylene terephthalate (PET) substrates and welded via flash white light and ultraviolet C (UV-C) irradiation to produce highly conductive transparent electrodes. The coated silver nanowire films were firmly welded and embedded into PET substrate successfully at room temperature and under ambient conditions using an in-house flash white light welding system and UV-C irradiation. The effects of light irradiation conditions (light energy, irradiation time, pulse duration, and pulse number) on the silver nanowire networks were studied and optimized. Bending fatigue tests were also conducted to characterize the reliability of the welded transparent conductive silver nanowire films. The surfaces of the welded silver nanowire films were analyzed via scanning electron microscopy (SEM), while the transmittance of the structures was measured using a spectrophotometer. From the results, a highly conductive and transparent silver nanowire film with excellent reliability could be achieved at room temperature under ambient conditions via the combined flash white light and UV-C irradiation welding process. PMID:27553755
Cui, Yanyan; Chai, Jingchao; Du, Huiping; Duan, Yulong; Xie, Guangwen; Liu, Zhihong; Cui, Guanglei
2017-03-15
Polycyanoacrylate is a very promising matrix for polymer electrolyte, which possesses advantages of strong binding and high electrochemical stability owing to the functional nitrile groups. Herein, a facile and reliable in situ polymerization strategy of poly(ethyl cyanoacrylate) (PECA) based gel polymer electrolytes (GPE) via a high efficient anionic polymerization was introduced consisting of PECA and 4 M LiClO 4 in carbonate solvents. The in situ polymerized PECA gel polymer electrolyte achieved an excellent ionic conductivity (2.7 × 10 -3 S cm -1 ) at room temperature, and exhibited a considerable electrochemical stability window up to 4.8 V vs Li/Li + . The LiFePO 4 /PECA-GPE/Li and LiNi 1.5 Mn 0.5 O 4 /PECA-GPE/Li batteries using this in-situ-polymerized GPE delivered stable charge/discharge profiles, considerable rate capability, and excellent cycling performance. These results demonstrated this reliable in situ polymerization process is a very promising strategy to prepare high performance polymer electrolytes for flexible thin-film batteries, micropower lithium batteries, and deformable lithium batteries for special purpose.
Reliable data storage system design and implementation for acoustic logging while drilling
NASA Astrophysics Data System (ADS)
Hao, Xiaolong; Ju, Xiaodong; Wu, Xiling; Lu, Junqiang; Men, Baiyong; Yao, Yongchao; Liu, Dong
2016-12-01
Owing to the limitations of real-time transmission, reliable downhole data storage and fast ground reading have become key technologies in developing tools for acoustic logging while drilling (LWD). In order to improve the reliability of the downhole storage system in conditions of high temperature, intensive shake and periodic power supply, improvements were made in terms of hardware and software. In hardware, we integrated the storage system and data acquisition control module into one circuit board, to reduce the complexity of the storage process, by adopting the controller combination of digital signal processor and field programmable gate array. In software, we developed a systematic management strategy for reliable storage. Multiple-backup independent storage was employed to increase the data redundancy. A traditional error checking and correction (ECC) algorithm was improved and we embedded the calculated ECC code into all management data and waveform data. A real-time storage algorithm for arbitrary length data was designed to actively preserve the storage scene and ensure the independence of the stored data. The recovery procedure of management data was optimized to realize reliable self-recovery. A new bad block management idea of static block replacement and dynamic page mark was proposed to make the period of data acquisition and storage more balanced. In addition, we developed a portable ground data reading module based on a new reliable high speed bus to Ethernet interface to achieve fast reading of the logging data. Experiments have shown that this system can work stably below 155 °C with a periodic power supply. The effective ground data reading rate reaches 1.375 Mbps with 99.7% one-time success rate at room temperature. This work has high practical application significance in improving the reliability and field efficiency of acoustic LWD tools.
Multilayer Lead-Free Ceramic Capacitors with Ultrahigh Energy Density and Efficiency.
Li, Jinglei; Li, Fei; Xu, Zhuo; Zhang, Shujun
2018-06-26
The utilization of antiferroelectric (AFE) materials is thought to be an effective approach to enhance the energy density of dielectric capacitors. However, the high energy dissipation and inferior reliability that are associated with the antiferroelectric-ferroelectric phase transition are the main issues that restrict the applications of antiferroelectric ceramics. Here, simultaneously achieving high energy density and efficiency in a dielectric ceramic is proposed by combining antiferroelectric and relaxor features. Based on this concept, a lead-free dielectric (Na 0.5 Bi 0.5 )TiO 3 -x(Sr 0.7 Bi 0.2 )TiO 3 (NBT-xSBT) system is investigated and the corresponding multilayer ceramic capacitors (MLCCs) are fabricated. A record-high energy density of 9.5 J cm -3 , together with a high energy efficiency of 92%, is achieved in NBT-0.45SBT multilayer ceramic capacitors, which consist of ten dielectric layers with the single-layer thickness of 20 µm and the internal electrode area of 6.25 mm 2 . Furthermore, the newly developed capacitor exhibits a wide temperature usage range of -60 to 120 °C, with an energy-density variation of less than 10%, and satisfactory cycling reliability, with degradation of less than 8% over 10 6 cycles. These characteristics demonstrate that the NBT-0.45SBT multilayer ceramic is a promising candidate for high-power energy storage applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Divito, Ben L.; Butler, Ricky W.; Caldwell, James L.
1990-01-01
A high-level design is presented for a reliable computing platform for real-time control applications. Design tradeoffs and analyses related to the development of the fault-tolerant computing platform are discussed. The architecture is formalized and shown to satisfy a key correctness property. The reliable computing platform uses replicated processors and majority voting to achieve fault tolerance. Under the assumption of a majority of processors working in each frame, it is shown that the replicated system computes the same results as a single processor system not subject to failures. Sufficient conditions are obtained to establish that the replicated system recovers from transient faults within a bounded amount of time. Three different voting schemes are examined and proved to satisfy the bounded recovery time conditions.
National audit of continence care: laying the foundation.
Mian, Sarah; Wagg, Adrian; Irwin, Penny; Lowe, Derek; Potter, Jonathan; Pearson, Michael
2005-12-01
National audit provides a basis for establishing performance against national standards, benchmarking against other service providers and improving standards of care. For effective audit, clinical indicators are required that are valid, feasible to apply and reliable. This study describes the methods used to develop clinical indicators of continence care in preparation for a national audit. To describe the methods used to develop and test clinical indicators of continence care with regard to validity, feasibility and reliability. A multidisciplinary working group developed clinical indicators that measured the structure, process and outcome of care as well as case-mix variables. Literature searching, consensus workshops and a Delphi process were used to develop the indicators. The indicators were tested in 15 secondary care sites, 15 primary care sites and 15 long-term care settings. The process of development produced indicators that received a high degree of consensus within the Delphi process. Testing of the indicators demonstrated an internal reliability of 0.7 and an external reliability of 0.6. Data collection required significant investment in terms of staff time and training. The method used produced indicators that achieved a high degree of acceptance from health care professionals. The reliability of data collection was high for this audit and was similar to the level seen in other successful national audits. Data collection for the indicators was feasible to collect, however, issues of time and staffing were identified as limitations to such data collection. The study has described a systematic method for developing clinical indicators for national audit. The indicators proved robust and reliable in primary and secondary care as well as long-term care settings.
Effectiveness of back-to-back testing
NASA Technical Reports Server (NTRS)
Vouk, Mladen A.; Mcallister, David F.; Eckhardt, David E.; Caglayan, Alper; Kelly, John P. J.
1987-01-01
Three models of back-to-back testing processes are described. Two models treat the case where there is no intercomponent failure dependence. The third model describes the more realistic case where there is correlation among the failure probabilities of the functionally equivalent components. The theory indicates that back-to-back testing can, under the right conditions, provide a considerable gain in software reliability. The models are used to analyze the data obtained in a fault-tolerant software experiment. It is shown that the expected gain is indeed achieved, and exceeded, provided the intercomponent failure dependence is sufficiently small. However, even with the relatively high correlation the use of several functionally equivalent components coupled with back-to-back testing may provide a considerable reliability gain. Implications of this finding are that the multiversion software development is a feasible and cost effective approach to providing highly reliable software components intended for fault-tolerant software systems, on condition that special attention is directed at early detection and elimination of correlated faults.
Digital Processing Of Young's Fringes In Speckle Photography
NASA Astrophysics Data System (ADS)
Chen, D. J.; Chiang, F. P.
1989-01-01
A new technique for fully automatic diffraction fringe measurement in point-wise speckle photograph analysis is presented in this paper. The fringe orientation and spacing are initially estimated with the help of 1-D FFT. A 2-D convolution filter is then applied to enhance the estimated image . High signal-to-noise rate (SNR) fringe pattern is achieved which makes it feasible for precise determination of the displacement components. The halo-effect is also optimally eliminated in a new way. With the computation time compared favorably with those of 2-D autocorrelation method and the iterative 2-D FFT method. High reliability and accurate determination of displacement components are achieved over a wide range of fringe density.
Verification and Validation in a Rapid Software Development Process
NASA Technical Reports Server (NTRS)
Callahan, John R.; Easterbrook, Steve M.
1997-01-01
The high cost of software production is driving development organizations to adopt more automated design and analysis methods such as rapid prototyping, computer-aided software engineering (CASE) tools, and high-level code generators. Even developers of safety-critical software system have adopted many of these new methods while striving to achieve high levels Of quality and reliability. While these new methods may enhance productivity and quality in many cases, we examine some of the risks involved in the use of new methods in safety-critical contexts. We examine a case study involving the use of a CASE tool that automatically generates code from high-level system designs. We show that while high-level testing on the system structure is highly desirable, significant risks exist in the automatically generated code and in re-validating releases of the generated code after subsequent design changes. We identify these risks and suggest process improvements that retain the advantages of rapid, automated development methods within the quality and reliability contexts of safety-critical projects.
Southwestern Power Administration Annual Report 2008
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-12-01
Dear Secretary Chu, I am pleased to present the financial statements and operating data for Southwestern Power Administration (Southwestern) for Fiscal Year (FY) 2008. In FY 2008, Southwestern delivered over 7.3 billion kilowatt-hours of energy to its wholesale customers – nearly 31% more than average due to numerous record rainfall amounts in the southwest region. These record amounts produced revenues which exceeded the average annual revenue requirement by nearly $20 million and resulted in over $200 million in economic benefits to the region. Yet even as Southwestern exceeded its goals of marketing and delivering Federal hydroelectric power to our customers,more » we stayed focused on safety, security, and reliability. For example, we maintained our nearly 1,400 miles of high-voltage transmission lines, substations, and communications sites while achieving a Recordable Accident Frequency Rate of 0.0, a record that reflects Southwestern’s safety achievement of no recordable injuries for every 200,000 hours worked. We kept our rights-of-way secure from vegetation and other obstacles, work that not only supports our mission but also promotes reliability of the regional and National grid. We exceeded all North American Electric Reliability Corporation (NERC) Control Performance Standards (CPS- 1 and CPS-2), and maintained regulation and reserve obligations and reactive reserve margins to ensure the reliability of the bulk electric system, even during extended periods of restricted hydro operations due to unusually high project inflows. Finally, we continued our partnerships with the Department of Energy, the U.S. Army Corps of Engineers, our customers, and other Federal power stakeholders, partnerships that are vital to our continued success in marketing and delivering carbon-free, renewable, and domestically produced energy to our customers and to the Nation. Sincerely, Jon Worthington Administrator« less
Towards Integrating Distributed Energy Resources and Storage Devices in Smart Grid.
Xu, Guobin; Yu, Wei; Griffith, David; Golmie, Nada; Moulema, Paul
2017-02-01
Internet of Things (IoT) provides a generic infrastructure for different applications to integrate information communication techniques with physical components to achieve automatic data collection, transmission, exchange, and computation. The smart grid, as one of typical applications supported by IoT, denoted as a re-engineering and a modernization of the traditional power grid, aims to provide reliable, secure, and efficient energy transmission and distribution to consumers. How to effectively integrate distributed (renewable) energy resources and storage devices to satisfy the energy service requirements of users, while minimizing the power generation and transmission cost, remains a highly pressing challenge in the smart grid. To address this challenge and assess the effectiveness of integrating distributed energy resources and storage devices, in this paper we develop a theoretical framework to model and analyze three types of power grid systems: the power grid with only bulk energy generators, the power grid with distributed energy resources, and the power grid with both distributed energy resources and storage devices. Based on the metrics of the power cumulative cost and the service reliability to users, we formally model and analyze the impact of integrating distributed energy resources and storage devices in the power grid. We also use the concept of network calculus, which has been traditionally used for carrying out traffic engineering in computer networks, to derive the bounds of both power supply and user demand to achieve a high service reliability to users. Through an extensive performance evaluation, our data shows that integrating distributed energy resources conjointly with energy storage devices can reduce generation costs, smooth the curve of bulk power generation over time, reduce bulk power generation and power distribution losses, and provide a sustainable service reliability to users in the power grid.
Towards Integrating Distributed Energy Resources and Storage Devices in Smart Grid
Xu, Guobin; Yu, Wei; Griffith, David; Golmie, Nada; Moulema, Paul
2017-01-01
Internet of Things (IoT) provides a generic infrastructure for different applications to integrate information communication techniques with physical components to achieve automatic data collection, transmission, exchange, and computation. The smart grid, as one of typical applications supported by IoT, denoted as a re-engineering and a modernization of the traditional power grid, aims to provide reliable, secure, and efficient energy transmission and distribution to consumers. How to effectively integrate distributed (renewable) energy resources and storage devices to satisfy the energy service requirements of users, while minimizing the power generation and transmission cost, remains a highly pressing challenge in the smart grid. To address this challenge and assess the effectiveness of integrating distributed energy resources and storage devices, in this paper we develop a theoretical framework to model and analyze three types of power grid systems: the power grid with only bulk energy generators, the power grid with distributed energy resources, and the power grid with both distributed energy resources and storage devices. Based on the metrics of the power cumulative cost and the service reliability to users, we formally model and analyze the impact of integrating distributed energy resources and storage devices in the power grid. We also use the concept of network calculus, which has been traditionally used for carrying out traffic engineering in computer networks, to derive the bounds of both power supply and user demand to achieve a high service reliability to users. Through an extensive performance evaluation, our data shows that integrating distributed energy resources conjointly with energy storage devices can reduce generation costs, smooth the curve of bulk power generation over time, reduce bulk power generation and power distribution losses, and provide a sustainable service reliability to users in the power grid1. PMID:29354654
Wiggins, Ian M; Anderson, Carly A; Kitterick, Pádraig T; Hartley, Douglas E H
2016-09-01
Functional near-infrared spectroscopy (fNIRS) is a silent, non-invasive neuroimaging technique that is potentially well suited to auditory research. However, the reliability of auditory-evoked activation measured using fNIRS is largely unknown. The present study investigated the test-retest reliability of speech-evoked fNIRS responses in normally-hearing adults. Seventeen participants underwent fNIRS imaging in two sessions separated by three months. In a block design, participants were presented with auditory speech, visual speech (silent speechreading), and audiovisual speech conditions. Optode arrays were placed bilaterally over the temporal lobes, targeting auditory brain regions. A range of established metrics was used to quantify the reproducibility of cortical activation patterns, as well as the amplitude and time course of the haemodynamic response within predefined regions of interest. The use of a signal processing algorithm designed to reduce the influence of systemic physiological signals was found to be crucial to achieving reliable detection of significant activation at the group level. For auditory speech (with or without visual cues), reliability was good to excellent at the group level, but highly variable among individuals. Temporal-lobe activation in response to visual speech was less reliable, especially in the right hemisphere. Consistent with previous reports, fNIRS reliability was improved by averaging across a small number of channels overlying a cortical region of interest. Overall, the present results confirm that fNIRS can measure speech-evoked auditory responses in adults that are highly reliable at the group level, and indicate that signal processing to reduce physiological noise may substantially improve the reliability of fNIRS measurements. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Grotevant, Harold D., Adams, Gerald R.
1984-01-01
Three studies evaluating the reliability and validity of the Objective Measure of Ego Identity Status (OM-EIS) are reported. Two studies analyzed college students' results from the OM-EIS, the Extended Range Vocabulary Test, the Crowne-Marlowe Social Disability Scale and achievement records. Study 3 correlated high school seniors' OM-EIS scores…
ERIC Educational Resources Information Center
Data Quality Campaign, 2014
2014-01-01
State leaders are increasingly focused on improving college and university programs that prepare teachers as a route to a high-quality teacher workforce. This work requires significant data capacity to reliably and securely link teachers with their students' achievement and growth data with the state's teacher preparation programs. This fact sheet…
ERIC Educational Resources Information Center
CORTES, JUAN B.; AND OTHERS
THE VARIABLE, ACADEMIC MOTIVATION (N AC), WAS MEASURED BY A PROJECTIVE TEST. A SCORING MANUAL WITH HIGH INTER-SCORER RELIABILITY WAS ALSO PREPARED. THE 1964 FRESHMAN CLASS OF GEORGETOWN UNIVERSITY (N EQUALS 957) PARTICIPATED IN THE STUDY. ACADEMIC MOTIVATION CORRELATED POSITIVELY AND SIGNIFICANTLY FOR BOTH MALE AND FEMALE STUDENTS WITH GRADE POINT…
Economic Literacy, Teacher Instruction, and Preparation for the World of Work.
ERIC Educational Resources Information Center
Walstad, William B.; Soper, John C.
This paper analyzes the economic knowledge of high school students based on national data from 8,000 students who took the revised "Test of Economic Literacy," a nationally normed and standardized achievement test in economics. First, the validity and reliability features of the test are presented and then the test scores are broken down…
Barbado, David; Moreside, Janice; Vera-Garcia, Francisco J
2017-03-01
Although unstable seat methodology has been used to assess trunk postural control, the reliability of the variables that characterize it remains unclear. To analyze reliability and learning effect of center of pressure (COP) and kinematic parameters that characterize trunk postural control performance in unstable seating. The relationships between kinematic and COP parameters also were explored. Test-retest reliability design. Biomechanics laboratory setting. Twenty-three healthy male subjects. Participants volunteered to perform 3 sessions at 1-week intervals, each consisting of five 70-second balancing trials. A force platform and a motion capture system were used to measure COP and pelvis, thorax, and spine displacements. Reliability was assessed through standard error of measurement (SEM) and intraclass correlation coefficients (ICC 2,1 ) using 3 methods: (1) comparing the last trial score of each day; (2) comparing the best trial score of each day; and (3) calculating the average of the three last trial scores of each day. Standard deviation and mean velocity were calculated to assess balance performance. Although analyses of variance showed some differences in balance performance between days, these differences were not significant between days 2 and 3. Best result and average methods showed the greatest reliability. Mean velocity of the COP showed high reliability (0.71 < ICC < 0.86; 10.3 < SEM < 13.0), whereas standard deviation only showed a low to moderate reliability (0.37 < ICC < 0.61; 14.5 < SEM < 23.0). Regarding the kinematic variables, only pelvis displacement mean velocity achieved a high reliability using the average method (0.62 < ICC < 0.83; 18.8 < SEM < 23.1). Correlations between COP and kinematics were high only for mean velocity (0.45
Reliability and Maintainability Engineering - A Major Driver for Safety and Affordability
NASA Technical Reports Server (NTRS)
Safie, Fayssal M.
2011-01-01
The United States National Aeronautics and Space Administration (NASA) is in the midst of an effort to design and build a safe and affordable heavy lift vehicle to go to the moon and beyond. To achieve that, NASA is seeking more innovative and efficient approaches to reduce cost while maintaining an acceptable level of safety and mission success. One area that has the potential to contribute significantly to achieving NASA safety and affordability goals is Reliability and Maintainability (R&M) engineering. Inadequate reliability or failure of critical safety items may directly jeopardize the safety of the user(s) and result in a loss of life. Inadequate reliability of equipment may directly jeopardize mission success. Systems designed to be more reliable (fewer failures) and maintainable (fewer resources needed) can lower the total life cycle cost. The Department of Defense (DOD) and industry experience has shown that optimized and adequate levels of R&M are critical for achieving a high level of safety and mission success, and low sustainment cost. Also, lessons learned from the Space Shuttle program clearly demonstrated the importance of R&M engineering in designing and operating safe and affordable launch systems. The Challenger and Columbia accidents are examples of the severe impact of design unreliability and process induced failures on system safety and mission success. These accidents demonstrated the criticality of reliability engineering in understanding component failure mechanisms and integrated system failures across the system elements interfaces. Experience from the shuttle program also shows that insufficient Reliability, Maintainability, and Supportability (RMS) engineering analyses upfront in the design phase can significantly increase the sustainment cost and, thereby, the total life cycle cost. Emphasis on RMS during the design phase is critical for identifying the design features and characteristics needed for time efficient processing, improved operational availability, and optimized maintenance and logistic support infrastructure. This paper discusses the role of R&M in a program acquisition phase and the potential impact of R&M on safety, mission success, operational availability, and affordability. This includes discussion of the R&M elements that need to be addressed and the R&M analyses that need to be performed in order to support a safe and affordable system design. The paper also provides some lessons learned from the Space Shuttle program on the impact of R&M on safety and affordability.
Real-Time GNSS-Based Attitude Determination in the Measurement Domain.
Zhao, Lin; Li, Na; Li, Liang; Zhang, Yi; Cheng, Chun
2017-02-05
A multi-antenna-based GNSS receiver is capable of providing high-precision and drift-free attitude solution. Carrier phase measurements need be utilized to achieve high-precision attitude. The traditional attitude determination methods in the measurement domain and the position domain resolve the attitude and the ambiguity sequentially. The redundant measurements from multiple baselines have not been fully utilized to enhance the reliability of attitude determination. A multi-baseline-based attitude determination method in the measurement domain is proposed to estimate the attitude parameters and the ambiguity simultaneously. Meanwhile, the redundancy of attitude resolution has also been increased so that the reliability of ambiguity resolution and attitude determination can be enhanced. Moreover, in order to further improve the reliability of attitude determination, we propose a partial ambiguity resolution method based on the proposed attitude determination model. The static and kinematic experiments were conducted to verify the performance of the proposed method. When compared with the traditional attitude determination methods, the static experimental results show that the proposed method can improve the accuracy by at least 0.03° and enhance the continuity by 18%, at most. The kinematic result has shown that the proposed method can obtain an optimal balance between accuracy and reliability performance.
Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan
DOE Office of Scientific and Technical Information (OSTI.GOV)
Link, H.; Keller, J.; Guo, Y.
2013-04-01
Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE)more » through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.« less
Space Shuttle Software Development and Certification
NASA Technical Reports Server (NTRS)
Orr, James K.; Henderson, Johnnie A
2000-01-01
Man-rated software, "software which is in control of systems and environments upon which human life is critically dependent," must be highly reliable. The Space Shuttle Primary Avionics Software System is an excellent example of such a software system. Lessons learn from more than 20 years of effort have identified basic elements that must be present to achieve this high degree of reliability. The elements include rigorous application of appropriate software development processes, use of trusted tools to support those processes, quantitative process management, and defect elimination and prevention. This presentation highlights methods used within the Space Shuttle project and raises questions that must be addressed to provide similar success in a cost effective manner on future long-term projects where key application development tools are COTS rather than internally developed custom application development tools
High Power Laser Processing Of Materials
NASA Astrophysics Data System (ADS)
Martyr, D. R.; Holt, T.
1987-09-01
The first practical demonstration of a laser device was in 1960 and in the following years, the high power carbon dioxide laser has matured as an industrial machine tool. Modern carbon dioxide gas lasers can be used for cutting, welding, heat treatment, drilling, scribing and marking. Since their invention over 25 years ago they are now becoming recognised as highly reliable devices capable of achieving huge savings in production costs in many situations. This paper introduces the basic laser processing techniques of cutting, welding and heat treatment as they apply to the most common engineering materials. Typical processing speeds achieved with a wide range of laser powers are reported. Accuracies achievable and fit-up tolerances required are presented. Methods of integrating lasers with machine tools are described and their suitability in a wide range of manufacturing industries is described by reference to recent installations. Examples from small batch manufacturing, high volume production using dedicated laser welding equipment, and high volume manufacturing using 'flexible' automated laser welding equipment are described Future applications of laser processing are suggested by reference to current process developments.
Rezaei-Dehaghani, Abdollah; Keshvari, Mahrokh; Paki, Somayeh
2018-01-01
Nowadays, the most important problem of the educational system is the vast spread of school failure. Therefore, detection of the factors leading to or preventing students' academic achievement is of utmost importance. Family function is considered to be a critical component of academic success. This study aimed to investigate the relationship between family functioning and academic achievement in high school female students in Isfahan. This descriptive correlational study was conducted through random sampling among 237 female high school students in Isfahan during school year 2013-2014. Data were collected by participants' personal characteristics and Bloom family function questionnaires. To analyze the data, descriptive statistics (mean and standard deviation) and inferential statistics (Pearson correlation and linear regression analysis) were adopted and computed using SPSS software. The results showed a significant correlation between family function (except lack of independence) and students' academic achievement ( p < 0.05). Further, among family function dimensions, expressiveness ( β = 0.235, p < 0.001), family socialization ( β = 0.219, p = 0.001), and cohesion ( β = 0.211, p = 0.001) were more reliable predictors of academic achievement. The results of this study showed that students' academic achievement is highly correlated with the performance of their families. Therefore, to improve students' educational status in cultural and educational programs, which are specified for them, family function centered plans should be at the heart of attention.
Construction of Economics Achievement Test for Assessment of Students
ERIC Educational Resources Information Center
Osadebe, P. U.
2014-01-01
The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…
Turbine blade tip clearance measurements using skewed dual optical beams of tip timing
NASA Astrophysics Data System (ADS)
Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai
2011-12-01
Optimization and active control of the clearance between turbine blades and case of the engine is identified, especially in aerospace community, as a key technology to increase engine efficiency, reduce fuel consumption and emissions and increase service life .However, the tip clearance varies during different operating conditions. Thus a reliable non-contact and online detection system is essential and ultimately used to close the tip clearance control loop. This paper described a fiber optical clearance measuring system applying skewed dual optical beams to detect the traverse time of passing blades. Two beams were specially designed with an outward angle of 18 degree and the beam spot diameters are less than 100μm within 0-4mm working range to achieve high signal-to-noise and high sensitivity. It could be theoretically analyzed that the measuring accuracy is not compromised by degradation of signal intensity caused by any number of environmental conditions such as light source instability, contamination and blade tip imperfection. Experimental tests were undertaken to achieve a high resolution of 10µm in the rotational speed range 2000-18000RPM and a measurement accuracy of 15μm, indicating that the system is capable of providing accurate and reliable data for active clearance control (ACC).
Learning reliable manipulation strategies without initial physical models
NASA Technical Reports Server (NTRS)
Christiansen, Alan D.; Mason, Matthew T.; Mitchell, Tom M.
1990-01-01
A description is given of a robot, possessing limited sensory and effectory capabilities but no initial model of the effects of its actions on the world, that acquires such a model through exploration, practice, and observation. By acquiring an increasingly correct model of its actions, it generates increasingly successful plans to achieve its goals. In an apparently nondeterministic world, achieving reliability requires the identification of reliable actions and a preference for using such actions. Furthermore, by selecting its training actions carefully, the robot can significantly improve its learning rate.
Remote multi-function fire alarm system based on internet of things
NASA Astrophysics Data System (ADS)
Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu
2018-05-01
This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Xiangqi; Zhang, Yingchen
This paper presents an optimal voltage control methodology with coordination among different voltage-regulating resources, including controllable loads, distributed energy resources such as energy storage and photovoltaics (PV), and utility voltage-regulating devices such as voltage regulators and capacitors. The proposed methodology could effectively tackle the overvoltage and voltage regulation device distortion problems brought by high penetrations of PV to improve grid operation reliability. A voltage-load sensitivity matrix and voltage-regulator sensitivity matrix are used to deploy the resources along the feeder to achieve the control objectives. Mixed-integer nonlinear programming is used to solve the formulated optimization control problem. The methodology has beenmore » tested on the IEEE 123-feeder test system, and the results demonstrate that the proposed approach could actively tackle the voltage problem brought about by high penetrations of PV and improve the reliability of distribution system operation.« less
Status of the NASA Stirling Radioisotope Project
NASA Technical Reports Server (NTRS)
Schreiber, Jeffrey G.
2007-01-01
Free-piston Stirling power conversion has been considered a candidate for radioisotope power systems for space for more than a decade. Prior to the free-piston Stirling architecture, systems were designed with kinematic Stirling engines that used linkages and rotary alternators to convert heat to electricity. These systems were able to achieve long life by lightly loading the linkages; however, the live was nonetheless limited. When the free-piston configuration was initially proposed, it was thought to be attractive due to the relatively high conversion efficiency, acceptable mass, and the potential for long life and high reliability based on wear-free operation. These features have consistently been recognized by teams that have studied technology options for radioisotope space power systems. Since free-piston Stirling power conversion was first considered for space power applications, there have been major advances in three general areas of development: hardware that has demonstrated long-life and reliability, the success achieved by Stirling cryocoolers in space, and the overall developmental maturity of the technology for both space and terrestrial applications. Based on these advances, free-piston Stirling convertors are currently being developed for space power, and for a number of terrestrial applications. They commonly operate with the power, efficiency, life, and reliability as intended, and much of the development now centers on system integration. This paper will summarize the accomplishments of free-piston Stirling power conversion technology over the past decade, review the status of development with regard to space power, and discuss the challenges that remain.
Advanced flight control system study
NASA Technical Reports Server (NTRS)
Hartmann, G. L.; Wall, J. E., Jr.; Rang, E. R.; Lee, H. P.; Schulte, R. W.; Ng, W. K.
1982-01-01
A fly by wire flight control system architecture designed for high reliability includes spare sensor and computer elements to permit safe dispatch with failed elements, thereby reducing unscheduled maintenance. A methodology capable of demonstrating that the architecture does achieve the predicted performance characteristics consists of a hierarchy of activities ranging from analytical calculations of system reliability and formal methods of software verification to iron bird testing followed by flight evaluation. Interfacing this architecture to the Lockheed S-3A aircraft for flight test is discussed. This testbed vehicle can be expanded to support flight experiments in advanced aerodynamics, electromechanical actuators, secondary power systems, flight management, new displays, and air traffic control concepts.
Rutherford, Alex; Cebrian, Manuel; Dsouza, Sohan; Moro, Esteban; Pentland, Alex; Rahwan, Iyad
2013-01-01
The Internet and social media have enabled the mobilization of large crowds to achieve time-critical feats, ranging from mapping crises in real time, to organizing mass rallies, to conducting search-and-rescue operations over large geographies. Despite significant success, selection bias may lead to inflated expectations of the efficacy of social mobilization for these tasks. What are the limits of social mobilization, and how reliable is it in operating at these limits? We build on recent results on the spatiotemporal structure of social and information networks to elucidate the constraints they pose on social mobilization. We use the DARPA Network Challenge as our working scenario, in which social media were used to locate 10 balloons across the United States. We conduct high-resolution simulations for referral-based crowdsourcing and obtain a statistical characterization of the population recruited, geography covered, and time to completion. Our results demonstrate that the outcome is plausible without the presence of mass media but lies at the limit of what time-critical social mobilization can achieve. Success relies critically on highly connected individuals willing to mobilize people in distant locations, overcoming the local trapping of diffusion in highly dense areas. However, even under these highly favorable conditions, the risk of unsuccessful search remains significant. These findings have implications for the design of better incentive schemes for social mobilization. They also call for caution in estimating the reliability of this capability. PMID:23576719
Least Reliable Bits Coding (LRBC) for high data rate satellite communications
NASA Technical Reports Server (NTRS)
Vanderaar, Mark; Wagner, Paul; Budinger, James
1992-01-01
An analysis and discussion of a bandwidth efficient multi-level/multi-stage block coded modulation technique called Least Reliable Bits Coding (LRBC) is presented. LRBC uses simple multi-level component codes that provide increased error protection on increasingly unreliable modulated bits in order to maintain an overall high code rate that increases spectral efficiency. Further, soft-decision multi-stage decoding is used to make decisions on unprotected bits through corrections made on more protected bits. Using analytical expressions and tight performance bounds it is shown that LRBC can achieve increased spectral efficiency and maintain equivalent or better power efficiency compared to that of Binary Phase Shift Keying (BPSK). Bit error rates (BER) vs. channel bit energy with Additive White Gaussian Noise (AWGN) are given for a set of LRB Reed-Solomon (RS) encoded 8PSK modulation formats with an ensemble rate of 8/9. All formats exhibit a spectral efficiency of 2.67 = (log2(8))(8/9) information bps/Hz. Bit by bit coded and uncoded error probabilities with soft-decision information are determined. These are traded with with code rate to determine parameters that achieve good performance. The relative simplicity of Galois field algebra vs. the Viterbi algorithm and the availability of high speed commercial Very Large Scale Integration (VLSI) for block codes indicates that LRBC using block codes is a desirable method for high data rate implementations.
Evaluation of hydrate-screening methods.
Cui, Yong; Yao, Erica
2008-07-01
The purpose of this work is to evaluate the effectiveness and reliability of several common hydrate-screening techniques, and to provide guidelines for designing hydrate-screening programs for new drug candidates. Ten hydrate-forming compounds were selected as model compounds and six hydrate-screening approaches were applied to these compounds in an effort to generate their hydrate forms. The results prove that no screening approach is universally effective in finding hydrates for small organic compounds. Rather, a combination of different methods should be used to improve screening reliability. Among the approaches tested, the dynamic water vapor sorption/desorption isotherm (DVI) method and storage under high humidity (HH) yielded 60-70% success ratios, the lowest among all techniques studied. The risk of false negatives arises in particular for nonhygroscopic compounds. On the other hand, both slurry in water (Slurry) and temperature cycling of aqueous suspension (TCS) showed high success rates (90%) with some exceptions. The mixed solvent systems (MSS) procedure also achieved high success rates (90%), and was found to be more suitable for water-insoluble compounds. For water-soluble compounds, MSS may not be the best approach because recrystallization is difficult in solutions with high water activity. Finally, vapor diffusion (VD) yielded a reasonably high success ratio in finding hydrates (80%). However, this method suffers from experimental difficulty and unreliable results for either highly water-soluble or water-insoluble compounds. This study indicates that a reliable hydrate-screening strategy should take into consideration the solubility and hygroscopicity of the compounds studied. A combination of the Slurry or TCS method with the MSS procedure could provide a screening strategy with reasonable reliability.
Tipikin, D. S.; Earle, K. A.; Freed, J. H.
2010-01-01
The sensitivity of a high frequency electron spin resonance (ESR) spectrometer depends strongly on the structure used to couple the incident millimeter wave to the sample that generates the ESR signal. Subsequent coupling of the ESR signal to the detection arm of the spectrometer is also a crucial consideration for achieving high spectrometer sensitivity. In previous work, we found that a means for continuously varying the coupling was necessary for attaining high sensitivity reliably and reproducibly. We report here on a novel asymmetric mesh structure that achieves continuously variable coupling by rotating the mesh in its own plane about the millimeter wave transmission line optical axis. We quantify the performance of this device with nitroxide spin-label spectra in both a lossy aqueous solution and a low loss solid state system. These two systems have very different coupling requirements and are representative of the range of coupling achievable with this technique. Lossy systems in particular are a demanding test of the achievable sensitivity and allow us to assess the suitability of this approach for applying high frequency ESR to the study of biological systems at physiological conditions, for example. The variable coupling technique reported on here allows us to readily achieve a factor of ca. 7 improvement in signal to noise at 170 GHz and a factor of ca. 5 at 95 GHz over what has previously been reported for lossy samples. PMID:20458356
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carlson, J.J.; Bouchard, A.M.; Osbourn, G.C.
Future generation automated human biometric identification and verification will require multiple features/sensors together with internal and external information sources to achieve high performance, accuracy, and reliability in uncontrolled environments. The primary objective of the proposed research is to develop a theoretical and practical basis for identifying and verifying people using standoff biometric features that can be obtained with minimal inconvenience during the verification process. The basic problem involves selecting sensors and discovering features that provide sufficient information to reliably verify a person`s identity under the uncertainties caused by measurement errors and tactics of uncooperative subjects. A system was developed formore » discovering hand, face, ear, and voice features and fusing them to verify the identity of people. The system obtains its robustness and reliability by fusing many coarse and easily measured features into a near minimal probability of error decision algorithm.« less
Strapdown system redundancy management flight demonstration. [vertical takeoff and landing aircraft
NASA Technical Reports Server (NTRS)
1978-01-01
The suitability of strapdown inertial systems in providing highly reliable short-term navigation for vertical take-off and landing (VTOL) aircraft operating in an intra-urban setting under all-weather conditions was assessed. A preliminary design configuration of a skewed sensor inertial reference system employing a redundancy management concept to achieve fail-operational, fail-operational performance, was developed.
ERIC Educational Resources Information Center
Echols, Julie M. Young
2010-01-01
Reading proficiency is the goal of many local and national reading initiatives. A key component of these initiatives is accurate and reliable reading assessment. In this high-stakes testing arena, the Dynamic Indicators of Basic Early Literacy Skills (DIBELS) has emerged as a preferred measure for identification of students at risk for reading…
A Vertical Organic Transistor Architecture for Fast Nonvolatile Memory.
She, Xiao-Jian; Gustafsson, David; Sirringhaus, Henning
2017-02-01
A new device architecture for fast organic transistor memory is developed, based on a vertical organic transistor configuration incorporating high-performance ambipolar conjugated polymers and unipolar small molecules as the transport layers, to achieve reliable and fast programming and erasing of the threshold voltage shift in less than 200 ns. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Performance test results of 80 K centrifugal compressor for helium refrigerator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Asakura, H.; Kato, D.; Saji, N.
1994-12-31
The authors have developed a completely oil-free compressor used for the highly reliable helium refrigeration system for a superconducting generator and carried out performance tests under actual condition. The compressor is designed to achieve a pressure ratio of 8 with only 4 stages by cooling the compressor inlet at 80 K with liquid nitrogen, thus acquiring high reliability of long-term maintenance-free operation together with the use of magnetic bearings for oil-free operation. The compressor at each stage is independently driven by a 25 kW built-in motor at the speed of 100,000 rpm, with the power supplied by a variable frequencymore » inverter. The performance test was carried out at each stage, by incorporating the compressor in the closed loop test equipment using helium gas. It was recognized from the test results that the specified pressure ratio of each stage was achieved at the speed below the rated one of 100,000 rpm. It was found that each stage of the compressor has a flat characteristics of adiabatic efficiency over the wide flow range. The mechanical rotation characteristics at low temperatures was also confirmed to be sufficiently stable.« less
Compliance and High Reliability in a Complex Healthcare Organization.
Simon, Maxine dellaBadia
2018-01-01
When considering the impact of regulation on healthcare, visualize a spider's web. The spider weaves sections together to create the whole, with each fiber adding to the structure to support its success or lead to its failure. Each section is dependent on the others, and all must be aligned to maintain the structure. Outside forces can cause a shift in the web's fragile equilibrium.The interdependence of the sections of the spider's web is similar to the way hospital departments and services work together. An organization's structure must be shaped to support its mission and vision. At the same time, the business of healthcare requires the development and achievement of operational objectives and financial performance goals. Establishing a culture that is flexible enough to permit creativity, provide resiliency, and manage complexity as the organization grows is fundamental to success. An organization must address each of these factors while maintaining stability, carrying out its mission, and fostering improvement.Nature's order maintains the spider's web. Likewise, regulation can strengthen healthcare organizations by initiating disruptive changes that can support efforts to achieve and sustain high reliability in the delivery of care. To that end, leadership must be willing to provide the necessary vision and resources.
Evaluation of a primary care adult mental health service: Year 2
2013-01-01
Aims This study aimed to examine the effectiveness of a primary care adult mental health service operating within a stepped care model of service delivery. Methods Supervised by a principal psychologist manager, psychology graduate practitioners provided one-to-one brief cognitive behavioural therapy (CBT) to service users. The Clinical Outcomes in Routine Evaluation-Outcome Measure (CORE-OM) was used to assess service user treatment outcomes. Satisfaction questionnaires were administered to service users and referring general practitioners (GPs). Results A total of 43 individuals attended for an initial appointment, of whom 19 (44.2%) completed brief CBT treatment. Of the 13 service users who were in the clinical range pre-treatment, 11 (84.6%) achieved clinical and reliably significant improvement. Of the six service users who were in the non-clinical range pre-treatment, three (50%) achieved reliably significant improvement. Both service users and GPs indicated high levels of satisfaction with the service, although service accessibility was highlighted as needing improvement. Conclusion The service was effective in treating mild to moderate mental health problems in primary care. Stricter adherence to a stepped care model through the provision of low-intensity, high-throughput interventions would be desirable for future service provision. PMID:24381655
Reliability culture at La Silla Paranal Observatory
NASA Astrophysics Data System (ADS)
Gonzalez, Sergio
2010-07-01
The Maintenance Department at the La Silla - Paranal Observatory has been an important base to keep the operations of the observatory at a good level of reliability and availability. Several strategies have been implemented and improved in order to cover these requirements and keep the system and equipment working properly when it is required. For that reason, one of the latest improvements has been the introduction of the concept of reliability, which implies that we don't simply speak about reliability concepts. It involves much more than that. It involves the use of technologies, data collecting, data analysis, decision making, committees concentrated in analysis of failure modes and how they can be eliminated, aligning the results with the requirements of our internal partners and establishing steps to achieve success. Some of these steps have already been implemented: data collection, use of technologies, analysis of data, development of priority tools, committees dedicated to analyze data and people dedicated to reliability analysis. This has permitted us to optimize our process, analyze where we can improve, avoid functional failures, reduce the failures range in several systems and subsystems; all this has had a positive impact in terms of results for our Observatory. All these tools are part of the reliability culture that allows our system to operate with a high level of reliability and availability.
An Evaluation Method of Equipment Reliability Configuration Management
NASA Astrophysics Data System (ADS)
Wang, Wei; Feng, Weijia; Zhang, Wei; Li, Yuan
2018-01-01
At present, many equipment development companies have been aware of the great significance of reliability of the equipment development. But, due to the lack of effective management evaluation method, it is very difficult for the equipment development company to manage its own reliability work. Evaluation method of equipment reliability configuration management is to determine the reliability management capabilities of equipment development company. Reliability is not only designed, but also managed to achieve. This paper evaluates the reliability management capabilities by reliability configuration capability maturity model(RCM-CMM) evaluation method.
Concept Design of High Power Solar Electric Propulsion Vehicles for Human Exploration
NASA Technical Reports Server (NTRS)
Hoffman, David J.; Kerslake, Thomas W.; Hojnicki, Jeffrey S.; Manzella, David H.; Falck, Robert D.; Cikanek, Harry A., III; Klem, Mark D.; Free, James M.
2011-01-01
Human exploration beyond low Earth orbit will require enabling capabilities that are efficient, affordable and reliable. Solar electric propulsion (SEP) has been proposed by NASA s Human Exploration Framework Team as one option to achieve human exploration missions beyond Earth orbit because of its favorable mass efficiency compared to traditional chemical propulsion systems. This paper describes the unique challenges associated with developing a large-scale high-power (300-kWe class) SEP vehicle and design concepts that have potential to meet those challenges. An assessment of factors at the subsystem level that must be considered in developing an SEP vehicle for future exploration missions is presented. Overall concepts, design tradeoffs and pathways to achieve development readiness are discussed.
NASA Astrophysics Data System (ADS)
Capone, V.; Esposito, R.; Pardi, S.; Taurino, F.; Tortone, G.
2012-12-01
Over the last few years we have seen an increasing number of services and applications needed to manage and maintain cloud computing facilities. This is particularly true for computing in high energy physics, which often requires complex configurations and distributed infrastructures. In this scenario a cost effective rationalization and consolidation strategy is the key to success in terms of scalability and reliability. In this work we describe an IaaS (Infrastructure as a Service) cloud computing system, with high availability and redundancy features, which is currently in production at INFN-Naples and ATLAS Tier-2 data centre. The main goal we intended to achieve was a simplified method to manage our computing resources and deliver reliable user services, reusing existing hardware without incurring heavy costs. A combined usage of virtualization and clustering technologies allowed us to consolidate our services on a small number of physical machines, reducing electric power costs. As a result of our efforts we developed a complete solution for data and computing centres that can be easily replicated using commodity hardware. Our architecture consists of 2 main subsystems: a clustered storage solution, built on top of disk servers running GlusterFS file system, and a virtual machines execution environment. GlusterFS is a network file system able to perform parallel writes on multiple disk servers, providing this way live replication of data. High availability is also achieved via a network configuration using redundant switches and multiple paths between hypervisor hosts and disk servers. We also developed a set of management scripts to easily perform basic system administration tasks such as automatic deployment of new virtual machines, adaptive scheduling of virtual machines on hypervisor hosts, live migration and automated restart in case of hypervisor failures.
Assessing segment- and corridor-based travel-time reliability on urban freeways : final report.
DOT National Transportation Integrated Search
2016-09-01
Travel time and its reliability are intuitive performance measures for freeway traffic operations. The objective of this project was to quantify segment-based and corridor-based travel time reliability measures on urban freeways. To achieve this obje...
NASA Astrophysics Data System (ADS)
Grimaldi, C. S. L.; Casciello, D.; Coviello, I.; Lacava, T.; Pergola, N.; Tramutoli, V.
2011-05-01
Information acquired and provided in Near Real Time is fundamental in contributing to reduce the impact of different sea pollution sources on the maritime environment. Optical data acquired by sensors aboard meteorological satellites, thanks to their high temporal resolution as well as to their delivery policy, can be profitably used for a Near Real Time sea monitoring, provided that accurate and reliable methodologies for analysis and investigation are designed, implemented and fully assessed. In this paper, the results achieved by the application of an improved version of RST (Robust Satellite Technique) to oil spill detection and monitoring will be shown. In particular, thermal infrared data acquired by the NOAA-AVHRR (National Oceanic and Atmospheric Administration-Advanced Very High Resolution Radiometer) have been analyzed and a new RST-based change detection index applied to the case of the oil spills that occurred off the Kuwait and Saudi Arabian coasts in January 1991 and during the Lebanon War in July 2006. The results obtained, even in comparison with those achieved by other AVHRR-based techniques, confirm the unique performance of the proposed approach in automatically detecting the presence of oil spill with a high level of reliability and sensitivity. Moreover, the potential of the extension of the proposed technique to sensors onboard geostationary satellites will be discussed within the context of oil spill monitoring systems, integrating products generated by high temporal (optical) and high spatial (radar) resolution satellite systems.
Mirzamani, S Mahmood; Ashoori, Mohammad; Sereshki, Narges Adib
2011-01-01
This study investigates the effect of social and token economy reinforcements on academic achievement of 9th grade boy students with intellectual disabilities in an experimental science class in Tehran Province. The method used for this study was experimental by pre-test, post- test with a control group. The boy students with intellectual disabilities from three junior high schools participated in this study. The sample consisted of thirty, 9th grade boy students with intellectual disabilities in the selected schools; the schools were chosen by the multi-stage cluster method. To measure the progress of students in the science class, a teacher made test and the Wechsler intelligence test for matching the groups for IQ were used. To ensure validity, the content validity criteria depended tests calculated by the Lashe method and teachers' perspective were used. The reliability coefficient was obtained by the reliability coefficient of related tests; the percent agreement method and the obtained data were analyzed using one-way variance analysis and Shefe prosecution test. The results showed that there was a significant increase in academic achievement of students with intellectual disabilities when using token economy than using social reinforcements compared with the control group. Also, when using social reinforcements, the academic achievement of students was more than the control group. Token economy and social reinforcements increased the academic achievement of students with intellectual disabilities in the science class; and also the effect of token economy reinforcements was more than social reinforcements on the subjects.
Technologies for suppressing charge-traps in novel p-channel Field-MOSFET with thick gate oxide
NASA Astrophysics Data System (ADS)
Miyoshi, Tomoyuki; Oshima, Takayuki; Noguchi, Junji
2015-05-01
High voltage laterally diffused MOS (LDMOS) FETs are widely used in analog applications. A Field-MOSFET with a thick gate oxide is one of the best ways of achieving a simpler design and smaller circuit footprint for high-voltage analog circuits. This paper focuses on an approach to improving the reliability of p-channel Field-MOSFETs. By introducing a fluorine implantation process and terminating fluorine at the LOCOS bird’s beak, the gate oxide breakdown voltage could be raised to 350 V at a high-slew rate and the negative bias temperature instability (NBTI) shift could be kept to within 15% over a product’s lifetime. By controlling the amount of charge in the insulating layer through improving the interlayer dielectric (ILD) deposition processes, a higher BVDSS of 370 V and 10-year tolerability of 300 V were obtained with an assisted reduced surface electric field (RESURF) effect. These techniques can supply an efficient solution for ensuring reliable high-performance applications.
NASA Astrophysics Data System (ADS)
Chen, Wenjun; Deng, Dunying; Cheng, Yuanrong; Xiao, Fei
2015-07-01
The easy oxidation of copper is one critical obstacle to high-performance copper-filled isotropically conductive adhesives (ICAs). In this paper, a facile method to prepare highly reliable, highly conductive, and low-cost ICAs is reported. The copper fillers were treated by organic acids for oxidation prevention. Compared with ICA filled with untreated copper flakes, the ICA filled with copper flakes treated by different organic acids exhibited much lower bulk resistivity. The lowest bulk resistivity achieved was 4.5 × 10-5 Ω cm, which is comparable to that of commercially available Ag-filled ICA. After 500 h of 85°C/85% relative humidity (RH) aging, the treated ICAs showed quite stable bulk resistivity and relatively stable contact resistance. Through analyzing the results of x-ray diffraction, x-ray photoelectron spectroscopy, and thermogravimetric analysis, we found that, with the assistance of organic acids, the treated copper flakes exhibited resistance to oxidation, thus guaranteeing good performance.
Micromachined evaporators for AMTEC cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izenson, M.G.; Crowley, C.J.
1996-12-31
To achieve high cell efficiency and reliability, the capillary pumping system for Alkali Metal Thermal to Electric Conversion (AMTEC) must have three key characteristics: (1) very small pores to achieve a high capillary pumping head, (2) high permeability for the flow of liquid sodium to minimize internal losses, and (3) be made from a material that is exceptionally stable at high temperatures in a sodium environment. The authors have developed micromachining techniques to manufacture high performance evaporators for AMTEC cells. The evaporators have been fabricated from stainless steel, molybdenum, and a niobium alloy (Nb-1Zr). The regular, micromachined structure leads tomore » very high capillary pumping head with high permeability for liquid flow. Data from tests performed with common fluids at room temperature characterize the capillary pumping head and permeability of these structures. Three micromachined evaporators have been built into AMTEC cells and operated at temperatures up to 1,100 K. Results from these tests confirm the excellent pumping capabilities of the micromachined evaporators.« less
1980-04-01
incorporate the high reliability ceramic-packaged quartz crystal resonator developed at ERADCOM, and utilize beam -leaded devices wherever possible...the form of a truncated cylinder. The rather complex module outline is best accomplished through the use of a precast potting shell filled with a low...crossover connections are achieved by means of thick-film dielectric material. Chip components attached to the metallized substrate complete the circuits
Highlights and Perspectives from the CMS Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butler, Joel Nathan
2017-09-09
In 2016, the Large Hadron Collider provided proton-proton collisions at 13 TeV center-of-mass energy and achieved very high luminosity and reliability. The performance of the CMS Experiment in this running period and a selection of recent physics results are presented. These include precision measurements and searches for new particles. The status and prospects for data-taking in 2017 and a brief summary of the highlights of the High Luminosity (HL-LHC) upgrade of the CMS detector are also presented.
Xie, Ming; Lee, Chee Huei; Wang, Jiesheng; Yap, Yoke Khin; Bruno, Paola; Gruen, Dieter; Singh, Dileep; Routbort, Jules
2010-04-01
Boron-doped nanographite ensembles (NGEs) are interesting thermoelectric nanomaterials for high temperature applications. Rapid induction annealing and quenching has been applied to boron-doped NGEs using a relatively low-cost, highly reliable, laboratory built furnace to show that substantial improvements in thermoelectric power factors can be achieved using this methodology. Details of the design and performance of this compact induction furnace as well as results of the thermoelectric measurements will be reported here.
Nuclear transformation of eukaryotic microalgae: historical overview, achievements and problems.
León, Rosa; Fernández, Emilio
2007-01-01
Transformation of microalgae is a first step in their use for biotechnological applications involving foreign protein production or molecular modifications of specific cell metabolic pathways. Since the first reliable achievements of nuclear transformation in Chlamydomonas, other eukaryotic microalgae have become transformed with molecular markers that allow a direct selection. Different methods--glass beads, electroporation, particle bombardment, or Agrobacterium--and constructions have been set up in several organisms and successfully used. However, some problems associated with efficiency, integration, or stability of the transgenes still persist and are analysed herein. Though the number of microalgae species successfully transformed is not very high, prospects for transformation of many more are good enough on the basis of what has been achieved so far.
Jiang, Jiehui; Yan, Zhuangzhi; Kandachar, Prabhu; Freudenthal, Adinda
2010-05-01
High blood pressure (BP, hypertension) is a leading chronic condition in China and has become the main risk factor for many high-risk diseases, such as heart attacks. However, the platform for chronic disease measurement and management is still lacking, especially for underserved Chinese. To achieve the early diagnosis of hypertension, one BP monitoring system has been designed. The proposed design consists of three main parts: user domain, server domain, and channel domain. All three units and their materialization, validation tests on reliability, and usability are described in this paper, and the conclusion is that the current design concept is feasible and the system can be developed toward sufficient reliability and affordability with further optimization. This idea might also be extended into one platform for other physiological signals, such as blood sugar and ECG.
Reliability of the Kinetics of British Army Foot Drill in Untrained Personnel.
Rawcliffe, Alex J; Simpson, Richard J; Graham, Scott M; Psycharakis, Stelios G; Moir, Gavin L; Connaboy, Chris
2017-02-01
Rawcliffe, AJ, Simpson, RJ, Graham, SM, Psycharakis, SG, Moir, GL, and Connaboy, C. Reliability of the kinetics of British Army foot drill in untrained personnel. J Strength Cond Res 31(2): 435-444, 2017-The purpose of this study was to quantify the reliability of kinetic variables of British Army foot drill performance within untrained civilians and report the magnitude of vertical ground reaction force (vGRF) and vertical rate of force development (RFD) of foot drills. Fifteen recreational active males performed 3 testing sessions across a 1-week period, with each session separated by 24 hours. Within each testing session participants (mean ± SD; age 22.4 ± 1.7 years; height 177 ± 5.6 cm; weight 83 ± 8.7 kg) completed 10 trials of stand-at-attention (SaA), stand-at-ease (SaE), Halt, quick-march (QM) and a normal walking gait, with vGRF and vertical RFD measured on a force plate. Between-session and within-session reliability was calculated as systematic bias, coefficient of variation calculated from the typical error (CVte%), and intraclass correlation coefficient (ICC). Significant (p ≤ 0.05) between-session differences were found for the vGRF SaA and SaE, and vertical RFD SaA and SaE conditions. Significant (p ≤ 0.05) within-session differences were found for the vGRF SaA and SaE conditions. A mean vGRF CVte% ≤10% was observed across all foot drills. However, the mean vertical RFD CVte% observed was ≥10% (excluding SaE) across all foot drills. The ICC analyses indicated that the vGRF Halt, QM, SaA, and Walk condition achieved moderate to large levels of test-retest reliability, with only SaE failing to achieve an ICC value ≥0.75. The vertical RFD QM, SaE, and Walk condition achieved moderate levels of test-retest reliability, with Halt and SaA failing to achieve an ICC value ≥0.75. It was determined that a single familiarization session and using the mean of 8 trials of vGRF are required to achieve acceptable levels of reliability.
Chan, Teresa Man-Yee; Grock, Andrew; Paddock, Michael; Kulasegaram, Kulamakan; Yarris, Lalena M; Lin, Michelle
2016-12-01
Since 2014, Academic Life in Emergency Medicine (ALiEM) has used the Approved Instructional Resources (AIR) score to critically appraise online content. The primary goals of this study are to determine the interrater reliability (IRR) of the ALiEM AIR rating score and determine its correlation with expert educator gestalt. We also determine the minimum number of educator-raters needed to achieve acceptable reliability. Eight educators each rated 83 online educational posts with the ALiEM AIR scale. Items include accuracy, usage of evidence-based medicine, referencing, utility, and the Best Evidence in Emergency Medicine rating score. A generalizability study was conducted to determine IRR and rating variance contributions of facets such as rater, blogs, posts, and topic. A randomized selection of 40 blog posts previously rated through ALiEM AIR was then rated again by a blinded group of expert medical educators according to their gestalt. Their gestalt impression was subsequently correlated with the ALiEM AIR score. The IRR for the ALiEM AIR rating scale was 0.81 during the 6-month pilot period. Decision studies showed that at least 9 raters were required to achieve this reliability. Spearman correlations between mean AIR score and the mean expert gestalt ratings were 0.40 for recommendation for learners and 0.35 for their colleagues. The ALiEM AIR scale is a moderately to highly reliable, 5-question tool when used by medical educators for rating online resources. The score displays a fair correlation with expert educator gestalt in regard to the quality of the resources. The score displays a fair correlation with educator gestalt. Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Prasad, Narasimha S.; Kratovil, Patrick T.; Tucker, Sara C.; Vallestero, Neil J.; Khusid, Mark
2004-01-01
A free-space, line-of-sight, ground-based optical link at 1.5 microns is attractive for tactical communications because it would provide eye-safety, covertness and jam-proof operation. However, the effects of atmospheric turbulence have to be appropriately mitigated for achieving acceptable bit-error-rate (BER) for reliable dissemination of information. Models to predict achievable BER at 1.5 microns for several beam propagation schemes that include beam scanning have been developed for various turbulence conditions. In this paper, we report performance characterization of free-space, high-data (>1Gb/s) rate beam propagation parameters at 1.5 microns for achieving BER reduction under the presence of turbulence. For standard free-space optical links, the mean SNR limits the achievable BER to lesser than 10-6 for Cn2 (structure constant of refractive index fluctuations) around 10-12 m-2/3. To validate these models, simultaneous measurements of structure constant of refractive index fluctuations, Cn2, and coherence diameter over tactical ranges have been carried out and analyzed. The effect of input beam conditioning to reduce BER levels have been explored. Furthermore, single and multiple transmit beams in conjunction with single and multiple detector arrangements have been examined. Based on these measurements, it is shown that the advantages of input beam conditioning coupled with modified receiver geometric characteristics would provide a path for BER reduction and hence, appreciable enhancements in data link reliability.
Zuo, Xi-Nian; Xu, Ting; Jiang, Lili; Yang, Zhi; Cao, Xiao-Yan; He, Yong; Zang, Yu-Feng; Castellanos, F. Xavier; Milham, Michael P.
2013-01-01
While researchers have extensively characterized functional connectivity between brain regions, the characterization of functional homogeneity within a region of the brain connectome is in early stages of development. Several functional homogeneity measures were proposed previously, among which regional homogeneity (ReHo) was most widely used as a measure to characterize functional homogeneity of resting state fMRI (R-fMRI) signals within a small region (Zang et al., 2004). Despite a burgeoning literature on ReHo in the field of neuroimaging brain disorders, its test–retest (TRT) reliability remains unestablished. Using two sets of public R-fMRI TRT data, we systematically evaluated the ReHo’s TRT reliability and further investigated the various factors influencing its reliability and found: 1) nuisance (head motion, white matter, and cerebrospinal fluid) correction of R-fMRI time series can significantly improve the TRT reliability of ReHo while additional removal of global brain signal reduces its reliability, 2) spatial smoothing of R-fMRI time series artificially enhances ReHo intensity and influences its reliability, 3) surface-based R-fMRI computation largely improves the TRT reliability of ReHo, 4) a scan duration of 5 min can achieve reliable estimates of ReHo, and 5) fast sampling rates of R-fMRI dramatically increase the reliability of ReHo. Inspired by these findings and seeking a highly reliable approach to exploratory analysis of the human functional connectome, we established an R-fMRI pipeline to conduct ReHo computations in both 3-dimensions (volume) and 2-dimensions (surface). PMID:23085497
Temperature and Humidity Calibration of a Low-Cost Wireless Dust Sensor for Real-Time Monitoring.
Hojaiji, Hannaneh; Kalantarian, Haik; Bui, Alex A T; King, Christine E; Sarrafzadeh, Majid
2017-03-01
This paper introduces the design, calibration, and validation of a low-cost portable sensor for the real-time measurement of dust particles within the environment. The proposed design consists of low hardware cost and calibration based on temperature and humidity sensing to achieve accurate processing of airborne dust density. Using commercial particulate matter sensors, a highly accurate air quality monitoring sensor was designed and calibrated using real world variations in humidity and temperature for indoor and outdoor applications. Furthermore, to provide a low-cost secure solution for real-time data transfer and monitoring, an onboard Bluetooth module with AES data encryption protocol was implemented. The wireless sensor was tested against a Dylos DC1100 Pro Air Quality Monitor, as well as an Alphasense OPC-N2 optical air quality monitoring sensor for accuracy. The sensor was also tested for reliability by comparing the sensor to an exact copy of itself under indoor and outdoor conditions. It was found that accurate measurements under real-world humid and temperature varying and dynamically changing conditions were achievable using the proposed sensor when compared to the commercially available sensors. In addition to accurate and reliable sensing, this sensor was designed to be wearable and perform real-time data collection and transmission, making it easy to collect and analyze data for air quality monitoring and real-time feedback in remote health monitoring applications. Thus, the proposed device achieves high quality measurements at lower-cost solutions than commercially available wireless sensors for air quality.
High Reliability R-10 Windows Using Vacuum Insulating Glass Units
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stark, David
2012-08-16
The objective of this effort was for EverSealed Windows (“EverSealed” or “ESW”) to design, assemble, thermally and environmentally test and demonstrate a Vacuum Insulating Glass Unit (“VIGU” or “VIG”) that would enable a whole window to meet or exceed the an R-10 insulating value (U-factor ≤ 0.1). To produce a VIGU that could withstand any North American environment, ESW believed it needed to design, produce and use a flexible edge seal system. This is because a rigid edge seal, used by all other know VIG producers and developers, limits the size and/or thermal environment of the VIG to where themore » unit is not practical for typical IG sizes and cannot withstand severe outdoor environments. The rigid-sealed VIG’s use would be limited to mild climates where it would not have a reasonable economic payback when compared to traditional double-pane or triple-pane IGs. ESW’s goals, in addition to achieving a sufficiently high R-value to enable a whole window to achieve R-10, included creating a VIG design that could be produced for a cost equal to or lower than a traditional triple-pane IG (low-e, argon filled). ESW achieved these goals. EverSealed produced, tested and demonstrated a flexible edge-seal VIG that had an R-13 insulating value and the edge-seal system durability to operate reliably for at least 40 years in the harshest climates of North America.« less
Design of fuel cell powered data centers for sufficient reliability and availability
NASA Astrophysics Data System (ADS)
Ritchie, Alexa J.; Brouwer, Jacob
2018-04-01
It is challenging to design a sufficiently reliable fuel cell electrical system for use in data centers, which require 99.9999% uptime. Such a system could lower emissions and increase data center efficiency, but the reliability and availability of such a system must be analyzed and understood. Currently, extensive backup equipment is used to ensure electricity availability. The proposed design alternative uses multiple fuel cell systems each supporting a small number of servers to eliminate backup power equipment provided the fuel cell design has sufficient reliability and availability. Potential system designs are explored for the entire data center and for individual fuel cells. Reliability block diagram analysis of the fuel cell systems was accomplished to understand the reliability of the systems without repair or redundant technologies. From this analysis, it was apparent that redundant components would be necessary. A program was written in MATLAB to show that the desired system reliability could be achieved by a combination of parallel components, regardless of the number of additional components needed. Having shown that the desired reliability was achievable through some combination of components, a dynamic programming analysis was undertaken to assess the ideal allocation of parallel components.
ERIC Educational Resources Information Center
Jeffery, Daniel; Yankulov, Krassimir; Crerar, Alison; Ritchie, Kerry
2016-01-01
The psychometric measures of accuracy, reliability and validity of peer assessment are critical qualities for its use as a supplement to instructor grading. In this study, we seek to determine which factors related to peer review are the most influential on these psychometric measures, with a primary focus on the accuracy of peer assessment or how…
Reliable Characterization for Pyrolysis Bio-Oils Leads to Enhanced
Upgrading Methods | NREL Reliable Characterization for Pyrolysis Bio-Oils Leads to Enhanced Upgrading Methods Science and Technology Highlights Highlights in Research & Development Reliable Characterization for Pyrolysis Bio-Oils Leads to Enhanced Upgrading Methods Key Research Results Achievement As co
Design-for-reliability (DfR) of aerospace electronics: Attributes and challenges
NASA Astrophysics Data System (ADS)
Bensoussan, A.; Suhir, E.
The next generation of multi-beam satellite systems that would be able to provide effective interactive communication services will have to operate within a highly flexible architecture. One option to develop such flexibility is to employ microwaves and/or optoelectronic components and to make them reliable. The use of optoelectronic devices, equipments and systems will result indeed in significant improvement in the state-of-the-art only provided that the new designs will suggest a novel and effective architecture that will combine the merits of good functional performance, satisfactory mechanical (structural) reliability and high cost effectiveness. The obvious challenge is the ability to design and fabricate equipment based on EEE components that would be able to successfully withstand harsh space environments for the entire duration of the mission. It is imperative that the major players in the space industry, such as manufacturers, industrial users, and space agencies, understand the importance and the limits of the achievable quality and reliability of optoelectronic devices operated in harsh environments. It is equally imperative that the physics of possible failures is well understood and, if necessary, minimized, and that adequate Quality Standards are developed and employed. The space community has to identify and to develop the strategic approach for validating optoelectronic products. This should be done with consideration of numerous intrinsic and extrinsic requirements for the systems' performance. When considering a particular next generation optoelectronic space system, the space community needs to address the following major issues: proof of concept for this system, proof of reliability and proof of performance. This should be done with taking into account the specifics of the anticipated application. High operational reliability cannot be left to the prognostics and health monitoring/management (PHM) effort and stage, no matter how important and - ffective such an effort might be. Reliability should be pursued at all the stages of the equipment lifetime: design, product development, manufacturing, burn-in testing and, of course, subsequent PHM after the space apparatus is launched and operated.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J
2016-01-01
Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP-root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. All criteria for feasibility were achieved. Mean V'O2peak was 106±9% of predicted V'O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V'O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V'O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training.
Stoller, Oliver; Schindelholz, Matthias; Hunt, Kenneth J.
2016-01-01
Background Neurological impairments can limit the implementation of conventional cardiopulmonary exercise testing (CPET) and cardiovascular training strategies. A promising approach to provoke cardiovascular stress while facilitating task-specific exercise in people with disabilities is feedback-controlled robot-assisted end-effector-based stair climbing (RASC). The aim of this study was to evaluate the feasibility, reliability, and repeatability of augmented RASC-based CPET in able-bodied subjects, with a view towards future research and applications in neurologically impaired populations. Methods Twenty able-bodied subjects performed a familiarisation session and 2 consecutive incremental CPETs using augmented RASC. Outcome measures focussed on standard cardiopulmonary performance parameters and on accuracy of work rate tracking (RMSEP−root mean square error). Criteria for feasibility were cardiopulmonary responsiveness and technical implementation. Relative and absolute test-retest reliability were assessed by intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and minimal detectable change (MDC). Mean differences, limits of agreement, and coefficients of variation (CoV) were estimated to assess repeatability. Results All criteria for feasibility were achieved. Mean V′O2peak was 106±9% of predicted V′O2max and mean HRpeak was 99±3% of predicted HRmax. 95% of the subjects achieved at least 1 criterion for V′O2max, and the detection of the sub-maximal ventilatory thresholds was successful (ventilatory anaerobic threshold 100%, respiratory compensation point 90% of the subjects). Excellent reliability was found for peak cardiopulmonary outcome measures (ICC ≥ 0.890, SEM ≤ 0.60%, MDC ≤ 1.67%). Repeatability for the primary outcomes was good (CoV ≤ 0.12). Conclusions RASC-based CPET with feedback-guided exercise intensity demonstrated comparable or higher peak cardiopulmonary performance variables relative to predicted values, achieved the criteria for V′O2max, and allowed determination of sub-maximal ventilatory thresholds. The reliability and repeatability were found to be high. There is potential for augmented RASC to be used for exercise testing and prescription in populations with neurological impairments who would benefit from repetitive task-specific training. PMID:26849137
Reliable bonding using indium-based solders
NASA Astrophysics Data System (ADS)
Cheong, Jongpil; Goyal, Abhijat; Tadigadapa, Srinivas; Rahn, Christopher
2004-01-01
Low temperature bonding techniques with high bond strengths and reliability are required for the fabrication and packaging of MEMS devices. Indium and indium-tin based bonding processes are explored for the fabrication of a flextensional MEMS actuator, which requires the integration of lead zirconate titanate (PZT) substrate with a silicon micromachined structure at low temperatures. The developed technique can be used either for wafer or chip level bonding. The lithographic steps used for the patterning and delineation of the seed layer limit the resolution of this technique. Using this technique, reliable bonds were achieved at a temperature of 200°C. The bonds yielded an average tensile strength of 5.41 MPa and 7.38 MPa for samples using indium and indium-tin alloy solders as the intermediate bonding layers respectively. The bonds (with line width of 100 microns) showed hermetic sealing capability of better than 10-11 mbar-l/s when tested using a commercial helium leak tester.
Reliable bonding using indium-based solders
NASA Astrophysics Data System (ADS)
Cheong, Jongpil; Goyal, Abhijat; Tadigadapa, Srinivas; Rahn, Christopher
2003-12-01
Low temperature bonding techniques with high bond strengths and reliability are required for the fabrication and packaging of MEMS devices. Indium and indium-tin based bonding processes are explored for the fabrication of a flextensional MEMS actuator, which requires the integration of lead zirconate titanate (PZT) substrate with a silicon micromachined structure at low temperatures. The developed technique can be used either for wafer or chip level bonding. The lithographic steps used for the patterning and delineation of the seed layer limit the resolution of this technique. Using this technique, reliable bonds were achieved at a temperature of 200°C. The bonds yielded an average tensile strength of 5.41 MPa and 7.38 MPa for samples using indium and indium-tin alloy solders as the intermediate bonding layers respectively. The bonds (with line width of 100 microns) showed hermetic sealing capability of better than 10-11 mbar-l/s when tested using a commercial helium leak tester.
Bipolar Nickel-hydrogen Batteries for Aerospace Applications
NASA Technical Reports Server (NTRS)
Koehler, C. W.; Vanommering, G.; Puester, N. H.; Puglisi, V. J.
1984-01-01
A bipolar nickel-hydrogen battery which effectively addresses all key requirements for a spacecraft power system, including long-term reliability and low mass, is discussed. The design of this battery is discussed in the context of system requirements and nickel-hydrogen battery technology in general. To achieve the ultimate goal of an aerospace application of a bipolar Ni-H2 battery several objectives must be met in the design and development of the system. These objectives include: maximization of reliability and life; high specific energy and energy density; reasonable cost of manufacture, test, and integration; and ease in scaling for growth in power requirements. These basic objectives translate into a number of specific design requirements, which are discussed.
Terrapin technologies manned Mars mission proposal
NASA Technical Reports Server (NTRS)
Amato, Michael; Bryant, Heather; Coleman, Rodney; Compy, Chris; Crouse, Patrick; Crunkleton, Joe; Hurtado, Edgar; Iverson, Eirik; Kamosa, Mike; Kraft, Lauri (Editor)
1990-01-01
A Manned Mars Mission (M3) design study is proposed. The purpose of M3 is to transport 10 personnel and a habitat with all required support systems and supplies from low Earth orbit (LEO) to the surface of Mars and, after an eight-man surface expedition of 3 months, to return the personnel safely to LEO. The proposed hardware design is based on systems and components of demonstrated high capability and reliability. The mission design builds on past mission experience, but incorporates innovative design approaches to achieve mission priorities. Those priorities, in decreasing order of importance, are safety, reliability, minimum personnel transfer time, minimum weight, and minimum cost. The design demonstrates the feasibility and flexibility of a Waverider transfer module.
Aslam, Tariq Mehmood; Shakir, Savana; Wong, James; Au, Leon; Ashworth, Jane
2012-12-01
Mucopolysaccharidoses (MPS) can cause corneal opacification that is currently difficult to objectively quantify. With newer treatments for MPS comes an increased need for a more objective, valid and reliable index of disease severity for clinical and research use. Clinical evaluation by slit lamp is very subjective and techniques based on colour photography are difficult to standardise. In this article the authors present evidence for the utility of dedicated image analysis algorithms applied to images obtained by a highly sophisticated iris recognition camera that is small, manoeuvrable and adapted to achieve rapid, reliable and standardised objective imaging in a wide variety of patients while minimising artefactual interference in image quality.
Photopolymer based VPHGs: from materials to sky results
NASA Astrophysics Data System (ADS)
Zanutta, A.; Orselli, E.; Fäcke, T.; Bianco, A.
2016-07-01
Volume Phase Holographic Gratings cover a relevant position as transmission dispersing elements in astronomical spectrographs and each astronomical observation could take advantage of specific dispersive elements with features tailored for achieving the best performances. The design and manufacturing of high efficiency and reliable VPHGs require photosensitive materials where it is possible to control both the refractive index modulation and the film thickness. By means of Bayfol® HX photopolymers, we designed and manufactured six VPHGs for astronomical instrumentation in a GRISM configuration. We demonstrated how photopolymers are reliable holographic materials for making astronomical VPHGs with performances comparable to those provided by VPHGs based on Dichromated Gelatins (DCGs), but with a much simpler production process.
Real-Time GNSS-Based Attitude Determination in the Measurement Domain
Zhao, Lin; Li, Na; Li, Liang; Zhang, Yi; Cheng, Chun
2017-01-01
A multi-antenna-based GNSS receiver is capable of providing high-precision and drift-free attitude solution. Carrier phase measurements need be utilized to achieve high-precision attitude. The traditional attitude determination methods in the measurement domain and the position domain resolve the attitude and the ambiguity sequentially. The redundant measurements from multiple baselines have not been fully utilized to enhance the reliability of attitude determination. A multi-baseline-based attitude determination method in the measurement domain is proposed to estimate the attitude parameters and the ambiguity simultaneously. Meanwhile, the redundancy of attitude resolution has also been increased so that the reliability of ambiguity resolution and attitude determination can be enhanced. Moreover, in order to further improve the reliability of attitude determination, we propose a partial ambiguity resolution method based on the proposed attitude determination model. The static and kinematic experiments were conducted to verify the performance of the proposed method. When compared with the traditional attitude determination methods, the static experimental results show that the proposed method can improve the accuracy by at least 0.03° and enhance the continuity by 18%, at most. The kinematic result has shown that the proposed method can obtain an optimal balance between accuracy and reliability performance. PMID:28165434
Maximally reliable spatial filtering of steady state visual evoked potentials.
Dmochowski, Jacek P; Greaves, Alex S; Norcia, Anthony M
2015-04-01
Due to their high signal-to-noise ratio (SNR) and robustness to artifacts, steady state visual evoked potentials (SSVEPs) are a popular technique for studying neural processing in the human visual system. SSVEPs are conventionally analyzed at individual electrodes or linear combinations of electrodes which maximize some variant of the SNR. Here we exploit the fundamental assumption of evoked responses--reproducibility across trials--to develop a technique that extracts a small number of high SNR, maximally reliable SSVEP components. This novel spatial filtering method operates on an array of Fourier coefficients and projects the data into a low-dimensional space in which the trial-to-trial spectral covariance is maximized. When applied to two sample data sets, the resulting technique recovers physiologically plausible components (i.e., the recovered topographies match the lead fields of the underlying sources) while drastically reducing the dimensionality of the data (i.e., more than 90% of the trial-to-trial reliability is captured in the first four components). Moreover, the proposed technique achieves a higher SNR than that of the single-best electrode or the Principal Components. We provide a freely-available MATLAB implementation of the proposed technique, herein termed "Reliable Components Analysis". Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Abramov, Ivan
2018-03-01
Development of design documentation for a future construction project gives rise to a number of issues with the main one being selection of manpower for structural units of the project's overall implementation system. Well planned and competently staffed integrated structural construction units will help achieve a high level of reliability and labor productivity and avoid negative (extraordinary) situations during the construction period eventually ensuring improved project performance. Research priorities include the development of theoretical recommendations for enhancing reliability of a structural unit staffed as an integrated construction crew. The author focuses on identification of destabilizing factors affecting formation of an integrated construction crew; assessment of these destabilizing factors; based on the developed mathematical model, highlighting the impact of these factors on the integration criterion with subsequent identification of an efficiency and reliability criterion for the structural unit in general. The purpose of this article is to develop theoretical recommendations and scientific and methodological provisions of an organizational and technological nature in order to identify a reliability criterion for a structural unit based on manpower integration and productivity criteria. With this purpose in mind, complex scientific tasks have been defined requiring special research, development of corresponding provisions and recommendations based on the system analysis findings presented herein.
ERIC Educational Resources Information Center
Ingles, Candido J.; Garcia-Fernandez, Jose M.; Castejon, Juan L.; Valle, Antonio; Delgado, Beatriz; Marzo, Juan C.
2009-01-01
This study examined the reliability and validity evidence drawn from the scores of the Spanish version of the Achievement Goal Tendencies Questionnaire (AGTQ) using a sample of 2,022 (51.1% boys) Spanish students from grades 7 to 10. Confirmatory factor analysis replicated the correlated three-factor structure of the AGTQ in this sample: Learning…
Design and Implementation of Secure and Reliable Communication using Optical Wireless Communication
NASA Astrophysics Data System (ADS)
Saadi, Muhammad; Bajpai, Ambar; Zhao, Yan; Sangwongngam, Paramin; Wuttisittikulkij, Lunchakorn
2014-11-01
Wireless networking intensify the tractability in the home and office environment to connect the internet without wires but at the cost of risks associated with stealing the data or threat of loading malicious code with the intention of harming the network. In this paper, we proposed a novel method of establishing a secure and reliable communication link using optical wireless communication (OWC). For security, spatial diversity based transmission using two optical transmitters is used and the reliability in the link is achieved by a newly proposed method for the construction of structured parity check matrix for binary Low Density Parity Check (LDPC) codes. Experimental results show that a successful secure and reliable link between the transmitter and the receiver can be achieved by using the proposed novel technique.
A gigawatt level repetitive rate adjustable magnetic pulse compressor.
Li, Song; Gao, Jing-Ming; Yang, Han-Wu; Qian, Bao-Liang; Li, Ze-Xin
2015-08-01
In this paper, a gigawatt level repetitive rate adjustable magnetic pulse compressor is investigated both numerically and experimentally. The device has advantages of high power level, high repetitive rate achievability, and long lifetime reliability. Importantly, dominate parameters including the saturation time, the peak voltage, and even the compression ratio can be potentially adjusted continuously and reliably, which significantly expands the applicable area of the device and generators based on it. Specifically, a two-stage adjustable magnetic pulse compressor, utilized for charging the pulse forming network of a high power pulse generator, is designed with different compression ratios of 25 and 18 through an optimized design process. Equivalent circuit analysis shows that the modification of compression ratio can be achieved by just changing the turn number of the winding. At the same time, increasing inductance of the grounded inductor will decrease the peak voltage and delay the charging process. Based on these analyses, an adjustable compressor was built and studied experimentally in both the single shot mode and repetitive rate mode. Pulses with peak voltage of 60 kV and energy per pulse of 360 J were obtained in the experiment. The rise times of the pulses were compressed from 25 μs to 1 μs and from 18 μs to 1 μs, respectively, at repetitive rate of 20 Hz with good repeatability. Experimental results show reasonable agreement with analyses.
Enhancing recovery rates: lessons from year one of IAPT.
Gyani, Alex; Shafran, Roz; Layard, Richard; Clark, David M
2013-09-01
The English Improving Access to Psychological Therapies (IAPT) initiative aims to make evidence-based psychological therapies for depression and anxiety disorder more widely available in the National Health Service (NHS). 32 IAPT services based on a stepped care model were established in the first year of the programme. We report on the reliable recovery rates achieved by patients treated in the services and identify predictors of recovery at patient level, service level, and as a function of compliance with National Institute of Health and Care Excellence (NICE) Treatment Guidelines. Data from 19,395 patients who were clinical cases at intake, attended at least two sessions, had at least two outcomes scores and had completed their treatment during the period were analysed. Outcome was assessed with the patient health questionnaire depression scale (PHQ-9) and the anxiety scale (GAD-7). Data completeness was high for a routine cohort study. Over 91% of treated patients had paired (pre-post) outcome scores. Overall, 40.3% of patients were reliably recovered at post-treatment, 63.7% showed reliable improvement and 6.6% showed reliable deterioration. Most patients received treatments that were recommended by NICE. When a treatment not recommended by NICE was provided, recovery rates were reduced. Service characteristics that predicted higher reliable recovery rates were: high average number of therapy sessions; higher step-up rates among individuals who started with low intensity treatment; larger services; and a larger proportion of experienced staff. Compliance with the IAPT clinical model is associated with enhanced rates of reliable recovery. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.
Modeling and Simulation Reliable Spacecraft On-Board Computing
NASA Technical Reports Server (NTRS)
Park, Nohpill
1999-01-01
The proposed project will investigate modeling and simulation-driven testing and fault tolerance schemes for Spacecraft On-Board Computing, thereby achieving reliable spacecraft telecommunication. A spacecraft communication system has inherent capabilities of providing multipoint and broadcast transmission, connectivity between any two distant nodes within a wide-area coverage, quick network configuration /reconfiguration, rapid allocation of space segment capacity, and distance-insensitive cost. To realize the capabilities above mentioned, both the size and cost of the ground-station terminals have to be reduced by using reliable, high-throughput, fast and cost-effective on-board computing system which has been known to be a critical contributor to the overall performance of space mission deployment. Controlled vulnerability of mission data (measured in sensitivity), improved performance (measured in throughput and delay) and fault tolerance (measured in reliability) are some of the most important features of these systems. The system should be thoroughly tested and diagnosed before employing a fault tolerance into the system. Testing and fault tolerance strategies should be driven by accurate performance models (i.e. throughput, delay, reliability and sensitivity) to find an optimal solution in terms of reliability and cost. The modeling and simulation tools will be integrated with a system architecture module, a testing module and a module for fault tolerance all of which interacting through a centered graphical user interface.
A Report on Simulation-Driven Reliability and Failure Analysis of Large-Scale Storage Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Lipeng; Wang, Feiyi; Oral, H. Sarp
High-performance computing (HPC) storage systems provide data availability and reliability using various hardware and software fault tolerance techniques. Usually, reliability and availability are calculated at the subsystem or component level using limited metrics such as, mean time to failure (MTTF) or mean time to data loss (MTTDL). This often means settling on simple and disconnected failure models (such as exponential failure rate) to achieve tractable and close-formed solutions. However, such models have been shown to be insufficient in assessing end-to-end storage system reliability and availability. We propose a generic simulation framework aimed at analyzing the reliability and availability of storagemore » systems at scale, and investigating what-if scenarios. The framework is designed for an end-to-end storage system, accommodating the various components and subsystems, their interconnections, failure patterns and propagation, and performs dependency analysis to capture a wide-range of failure cases. We evaluate the framework against a large-scale storage system that is in production and analyze its failure projections toward and beyond the end of lifecycle. We also examine the potential operational impact by studying how different types of components affect the overall system reliability and availability, and present the preliminary results« less
Modified personal interviews: resurrecting reliable personal interviews for admissions?
Hanson, Mark D; Kulasegaram, Kulamakan Mahan; Woods, Nicole N; Fechtig, Lindsey; Anderson, Geoff
2012-10-01
Traditional admissions personal interviews provide flexible faculty-student interactions but are plagued by low inter-interview reliability. Axelson and Kreiter (2009) retrospectively showed that multiple independent sampling (MIS) may improve reliability of personal interviews; thus, the authors incorporated MIS into the admissions process for medical students applying to the University of Toronto's Leadership Education and Development Program (LEAD). They examined the reliability and resource demands of this modified personal interview (MPI) format. In 2010-2011, LEAD candidates submitted written applications, which were used to screen for participation in the MPI process. Selected candidates completed four brief (10-12 minutes) independent MPIs each with a different interviewer. The authors blueprinted MPI questions to (i.e., aligned them with) leadership attributes, and interviewers assessed candidates' eligibility on a five-point Likert-type scale. The authors analyzed inter-interview reliability using the generalizability theory. Sixteen candidates submitted applications; 10 proceeded to the MPI stage. Reliability of the written application components was 0.75. The MPI process had overall inter-interview reliability of 0.79. Correlation between the written application and MPI scores was 0.49. A decision study showed acceptable reliability of 0.74 with only three MPIs scored using one global rating. Furthermore, a traditional admissions interview format would take 66% more time than the MPI format. The MPI format, used during the LEAD admissions process, achieved high reliability with minimal faculty resources. The MPI format's reliability and effective resource use were possible through MIS and employment of expert interviewers. MPIs may be useful for other admissions tasks.
Albitar, Adam; Ma, Wanlong; DeDios, Ivan; Estella, Jeffrey; Ahn, Inhye; Farooqui, Mohammed; Wiestner, Adrian; Albitar, Maher
2017-03-14
Patients with chronic lymphocytic leukemia (CLL) that develop resistance to Bruton tyrosine kinase (BTK) inhibitors are typically positive for mutations in BTK or phospholipase c gamma 2 (PLCγ2). We developed a high sensitivity (HS) assay utilizing wild-type blocking polymerase chain reaction achieved via bridged and locked nucleic acids. We used this high sensitivity assay in combination with Sanger sequencing and next generation sequencing (NGS) and tested cellular DNA and cell-free DNA (cfDNA) from patients with CLL treated with the BTK inhibitor, ibrutinib. We also tested ibrutinib-naïve patients with CLL. HS testing achieved 100x greater sensitivity than Sanger. HS Sanger sequencing was capable of detecting < 1 mutant allele in background of 1000 wild-type alleles (1:1000). Similar sensitivity was achieved with HS NGS. No BTK or PLCγ2 mutations were detected in any of the 44 ibrutinib-naïve CLL patients. We demonstrate that without the HS testing 56% of positive samples would have been missed for BTK and 85% of PLCγ2 would have been missed. With the use of HS, we were able to detect multiple mutant clones in the same sample in 37.5% of patients; most would have been missed without HS testing. We also demonstrate that with HS sequencing, plasma cfDNA is more reliable than cellular DNA in detecting mutations. Our studies indicate that wild-type blocking and HS sequencing is necessary for proper and early detection of BTK or PLCγ2 mutations in monitoring patients treated with BTK inhibitors. Furthermore, cfDNA from plasma is very reliable sample-type for testing.
Radio Detection of Cosmic Rays-Achievements and Future Potential
NASA Astrophysics Data System (ADS)
Huege, Tim
When modern efforts for radio detection of cosmic rays started about a decade ago, hopes were high but the true potential was unknown. Since then, we have achieved a detailed understanding of the radio emission physics and have consequently succeeded in developing sophisticated detection schemes and analysis approaches. In particular, we have demonstrated that the important air-shower parameters arrival direction, particle energy and depth of shower maximum can be reconstructed reliably from radio measurements, with a precision that is comparable with that of other detection techniques. At the same time, limitations inherent to the radio-emission mechanisms have become apparent. In this article, I shortly review the capabilities of radio detection in the very high-frequency band, and discuss the potential for future application in existing and new experiments for cosmic-ray detection.
Wanzek, Jeanne; Roberts, Greg; Linan-Thompson, Sylvia; Vaughn, Sharon; Woodruff, Althea L.; Murray, Christy S.
2011-01-01
The current study examined the predictive validity of oral reading fluency measures across first, second, and third grades for two reading achievement measures at the end of third grade. Oral reading fluency measures were administered to students from first grade to third. The Texas Assessment of Knowledge and Skills and the Stanford Achievement Test were also administered in the third grade. Oral reading fluency was a reliable predictor of student success on both measures. Data suggest that greater student growth in oral reading fluency is needed through the grade levels to ensure high probabilities of success on the nationally normed measure, as compared to what is needed for the state-normed measure. Implications for practice and future research are discussed. PMID:21479152
Tabuse, Hideaki; Kalali, Amir; Azuma, Hideki; Ozaki, Norio; Iwata, Nakao; Naitoh, Hiroshi; Higuchi, Teruhiko; Kanba, Shigenobu; Shioe, Kunihiko; Akechi, Tatsuo; Furukawa, Toshi A
2007-09-30
The Hamilton Rating Scale for Depression (HAMD) is the de facto international gold standard for the assessment of depression. There are some criticisms, however, especially with regard to its inter-rater reliability, due to the lack of standardized questions or explicit scoring procedures. The GRID-HAMD was developed to provide standardized explicit scoring conventions and a structured interview guide for administration and scoring of the HAMD. We developed the Japanese version of the GRID-HAMD and examined its inter-rater reliability among experienced and inexperienced clinicians (n=70), how rater characteristics may affect it, and how training can improve it in the course of a model training program using videotaped interviews. The results showed that the inter-rater reliability of the GRID-HAMD total score was excellent to almost perfect and those of most individual items were also satisfactory to excellent, both with experienced and inexperienced raters, and both before and after the training. With its standardized definitions, questions and detailed scoring conventions, the GRID-HAMD appears to be the best achievable set of interview guides for the HAMD and can provide a solid tool for highly reliable assessment of depression severity.
Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program
NASA Astrophysics Data System (ADS)
Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward
1993-08-01
A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.
Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH) program
NASA Technical Reports Server (NTRS)
Fayette, Daniel F.; Speicher, Patricia; Stoklosa, Mark J.; Evans, Jillian V.; Evans, John W.; Gentile, Mike; Pagel, Chuck A.; Hakim, Edward
1993-01-01
A joint military-commercial effort to evaluate multichip module (MCM) structures is discussed. The program, Reliability Technology to Achieve Insertion of Advanced Packaging (RELTECH), has been designed to identify the failure mechanisms that are possible in MCM structures. The RELTECH test vehicles, technical assessment task, product evaluation plan, reliability modeling task, accelerated and environmental testing, and post-test physical analysis and failure analysis are described. The information obtained through RELTECH can be used to address standardization issues, through development of cost effective qualification and appropriate screening criteria, for inclusion into a commercial specification and the MIL-H-38534 general specification for hybrid microcircuits.
Critical Analysis of Strategies for Determining Rigor in Qualitative Inquiry.
Morse, Janice M
2015-09-01
Criteria for determining the trustworthiness of qualitative research were introduced by Guba and Lincoln in the 1980s when they replaced terminology for achieving rigor, reliability, validity, and generalizability with dependability, credibility, and transferability. Strategies for achieving trustworthiness were also introduced. This landmark contribution to qualitative research remains in use today, with only minor modifications in format. Despite the significance of this contribution over the past four decades, the strategies recommended to achieve trustworthiness have not been critically examined. Recommendations for where, why, and how to use these strategies have not been developed, and how well they achieve their intended goal has not been examined. We do not know, for example, what impact these strategies have on the completed research. In this article, I critique these strategies. I recommend that qualitative researchers return to the terminology of social sciences, using rigor, reliability, validity, and generalizability. I then make recommendations for the appropriate use of the strategies recommended to achieve rigor: prolonged engagement, persistent observation, and thick, rich description; inter-rater reliability, negative case analysis; peer review or debriefing; clarifying researcher bias; member checking; external audits; and triangulation. © The Author(s) 2015.
Enhancing point of care vigilance using computers.
St Jacques, Paul; Rothman, Brian
2011-09-01
Information technology has the potential to provide a tremendous step forward in perioperative patient safety. Through automated delivery of information through fixed and portable computer resources, clinicians may achieve improved situational awareness of the overall operation of the operating room suite and the state of individual patients in various stages of surgical care. Coupling the raw, but integrated, information with decision support and alerting algorithms enables clinicians to achieve high reliability in documentation compliance and response to care protocols. Future studies and outcomes analysis are needed to quantify the degree of benefit of these new components of perioperative information systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Development of Camera Electronics for the Advanced Gamma-ray Imaging System (AGIS)
NASA Astrophysics Data System (ADS)
Tajima, Hiroyasu
2009-05-01
AGIS, a next generation of atmospheric Cherenkov telescope arrays, aims to achieve a sensitivity level of a milliCrab for gamma-ray observations in in the energy band of 40 GeV to 100 TeV. Such improvement requires cost reduction of individual components with high reliability in order to equip the order of 100 telescopes necessary to achieve the sensitivity goal. We are exploring several design concepts to reduce the cost of camera electronics while improving their performance. We have developed test systems for some of these concepts and are testing their performance. Here we present test results of the test systems.
The Advanced Gamma-ray Imaging System (AGIS) - Camera Electronics Development
NASA Astrophysics Data System (ADS)
Tajima, Hiroyasu; Bechtol, K.; Buehler, R.; Buckley, J.; Byrum, K.; Drake, G.; Falcone, A.; Funk, S.; Hanna, D.; Horan, D.; Humensky, B.; Karlsson, N.; Kieda, D.; Konopelko, A.; Krawczynski, H.; Krennrich, F.; Mukherjee, R.; Ong, R.; Otte, N.; Quinn, J.; Schroedter, M.; Swordy, S.; Wagner, R.; Wakely, S.; Weinstein, A.; Williams, D.; Camera Working Group; AGIS Collaboration
2010-03-01
AGIS, a next-generation imaging atmospheric Cherenkov telescope (IACT) array, aims to achieve a sensitivity level of about one milliCrab for gamma-ray observations in the energy band of 50 GeV to 100 TeV. Achieving this level of performance will require on the order of 50 telescopes with perhaps as many as 1M total electronics channels. The larger scale of AGIS requires a very different approach from the currently operating IACTs, with lower-cost and lower-power electronics incorporated into camera modules designed for high reliability and easy maintenance. Here we present the concept and development status of the AGIS camera electronics.
Assuring reliability program effectiveness.
NASA Technical Reports Server (NTRS)
Ball, L. W.
1973-01-01
An attempt is made to provide simple identification and description of techniques that have proved to be most useful either in developing a new product or in improving reliability of an established product. The first reliability task is obtaining and organizing parts failure rate data. Other tasks are parts screening, tabulation of general failure rates, preventive maintenance, prediction of new product reliability, and statistical demonstration of achieved reliability. Five principal tasks for improving reliability involve the physics of failure research, derating of internal stresses, control of external stresses, functional redundancy, and failure effects control. A final task is the training and motivation of reliability specialist engineers.
Regenerative fuel cell study for satellites in GEO orbit
NASA Technical Reports Server (NTRS)
Vandine, Leslie; Gonzalez-Sanabria, Olga; Levy, Alexander
1987-01-01
The results of a 12 month study to identify high performance regenerative hydrogen-oxygen fuel cell concepts for geosynchronous satellite application are summarized. Emphasis was placed on concepts with the potential for high energy density and passive means for water and heat management to maximize system reliability. Both polymer membrane and alkaline electrolyte fuel cells were considered, with emphasis on the alkaline cell because of its high performance, advanced state of development, and proven ability to operate in a launch and space environment. Three alkaline system concepts were studied. Results indicate that using near term technology energy densities between 46 and 52 watt-hour/lb can be achieved at efficiencies of 55 percent. Using advanced light weight cell construction which was achieved in experimental cells, composite tankage material for the reactant gases and the reversible stack concept, system energy densities of 115 watt-hours/lb can be projected.
Tutorial: Performance and reliability in redundant disk arrays
NASA Technical Reports Server (NTRS)
Gibson, Garth A.
1993-01-01
A disk array is a collection of physically small magnetic disks that is packaged as a single unit but operates in parallel. Disk arrays capitalize on the availability of small-diameter disks from a price-competitive market to provide the cost, volume, and capacity of current disk systems but many times their performance. Unfortunately, relative to current disk systems, the larger number of components in disk arrays leads to higher rates of failure. To tolerate failures, redundant disk arrays devote a fraction of their capacity to an encoding of their information. This redundant information enables the contents of a failed disk to be recovered from the contents of non-failed disks. The simplest and least expensive encoding for this redundancy, known as N+1 parity is highlighted. In addition to compensating for the higher failure rates of disk arrays, redundancy allows highly reliable secondary storage systems to be built much more cost-effectively than is now achieved in conventional duplicated disks. Disk arrays that combine redundancy with the parallelism of many small-diameter disks are often called Redundant Arrays of Inexpensive Disks (RAID). This combination promises improvements to both the performance and the reliability of secondary storage. For example, IBM's premier disk product, the IBM 3390, is compared to a redundant disk array constructed of 84 IBM 0661 3 1/2-inch disks. The redundant disk array has comparable or superior values for each of the metrics given and appears likely to cost less. In the first section of this tutorial, I explain how disk arrays exploit the emergence of high performance, small magnetic disks to provide cost-effective disk parallelism that combats the access and transfer gap problems. The flexibility of disk-array configurations benefits manufacturer and consumer alike. In contrast, I describe in this tutorial's second half how parallelism, achieved through increasing numbers of components, causes overall failure rates to rise. Redundant disk arrays overcome this threat to data reliability by ensuring that data remains available during and after component failures.
The psychosocial inventory of ego strengths: examination of theory and psychometric properties.
Markstrom, Carol A; Marshall, Sheila K
2007-02-01
The psychosocial inventory of ego strengths (PIES) was devised as a measure of Erikson's eight ego strengths. The present investigation extended previous research through examination of the validity and reliability of the PIES among 502 high school students. The study also included an appraisal of Erikson's ego strengths as indices of psychosocial well-being. Reliability of the subscales of the PIES was shown through acceptable Cronbach's alphas. As expected, higher scores on ego strengths were positively correlated with psychosocial indictors of identity achievement, self-esteem, locus of control, empathic concern, perspective-taking, and positive forms of coping. Lower scores on ego strengths were related to less desirable psychosocial constructs. Biological sex and age differences also are reported. Based on the findings, the study offers validation of psychosocial theory. As well, the PIES is recommended for use among high school students.
High-power ultrashort fiber laser for solar cells micromachining
NASA Astrophysics Data System (ADS)
Lecourt, J.-B.; Duterte, C.; Liegeois, F.; Lekime, D.; Hernandez, Y.; Giannone, D.
2012-02-01
We report on a high-power ultra-short fiber laser for thin film solar cells micromachining. The laser is based on Chirped Pulse Amplification (CPA) scheme. The pulses are stretched to hundreds of picoseconds prior to amplification and can be compressed down to picosecond at high energy. The repetition rate is adjustable from 100 kHz to 1 MHz and the optical average output power is close to 13 W (before compression). The whole setup is fully fibred, except the compressor achieved with bulk gratings, resulting on a compact and reliable solution for cold ablation.
Mosmuller, David; Tan, Robin; Mulder, Frans; Bachour, Yara; de Vet, Henrica; Don Griot, Peter
2016-10-01
It is essential to have a reliable assessment method in order to compare the results of cleft lip and palate surgery. In this study the computer-based program SymNose, a method for quantitative assessment of the nose and lip, will be assessed on usability and reliability. The symmetry of the nose and lip was measured twice in 50 six-year-old complete and incomplete unilateral cleft lip and palate patients by four observers. For the frontal view the asymmetry level of the nose and upper lip were evaluated and for the basal view the asymmetry level of the nose and nostrils were evaluated. A mean inter-observer reliability when tracing each image once or twice was 0.70 and 0.75, respectively. Tracing the photographs with 2 observers and 4 observers gave a mean inter-observer score of 0.86 and 0.92, respectively. The mean intra-observer reliability varied between 0.80 and 0.84. SymNose is a practical and reliable tool for the retrospective assessment of large caseloads of 2D photographs of cleft patients for research purposes. Moderate to high single inter-observer reliability was found. For future research with SymNose reliable outcomes can be achieved by using the average outcomes of single tracings of two observers. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Malt, U F
1986-01-01
Experiences from teaching DSM-III to more than three hundred Norwegian psychiatrists and clinical psychologists suggest that reliable DSM-III diagnoses can be achieved within a few hours training with reference to the decision trees and the diagnostic criteria only. The diagnoses provided are more reliable than the corresponding ICD diagnoses which the participants were more familiar with. The three main sources of reduced reliability of the DSM-III diagnoses are related to: poor knowledge of the criteria which often is connected with failure of obtaining diagnostic key information during the clinical interview; unfamiliar concepts and vague or ambiguous criteria. The two first issues are related to the quality of the teaching of DSM-III. The third source of reduced reliability reflects unsolved validity issues. By using the classification of five affective case stories as examples, these sources of diagnostic pitfalls, reducing reliability and ways to overcome these problems when teaching the DSM-III system, are discussed. It is concluded that the DSM-III system of classification is easy to teach and that the system is superior to other classification systems available from a reliability point of view. The current version of the DSM-III system, however, partly owes a high degree of reliability to broad and heterogeneous diagnostic categories like the concept major depression, which may have questionable validity. Thus, the future revisions of the DSM-III system should, above all, address the issue of validity.
Inter- and intra-observer reliability of clinical movement-control tests for marines
2012-01-01
Background Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. Methods This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. Results Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. Conclusions Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain. PMID:23273285
Research and application of embedded real-time operating system
NASA Astrophysics Data System (ADS)
Zhang, Bo
2013-03-01
In this paper, based on the analysis of existing embedded real-time operating system, the architecture of an operating system is designed and implemented. The experimental results show that the design fully complies with the requirements of embedded real-time operating system, can achieve the purposes of reducing the complexity of embedded software design and improving the maintainability, reliability, flexibility. Therefore, this design program has high practical value.
Common Badging and Access Control System (CBACS)
NASA Technical Reports Server (NTRS)
Baldridge, Tim
2005-01-01
The goals of the project are: Achieve high business value through a common badging and access control system that integrates with smart cards. Provide physical (versus logical) deployment of smart cards initially. Provides a common consistent and reliable environment into which to release the smart card. Gives opportunity to develop agency-wide consistent processes, practices and policies. Enables enterprise data capture and management. Promotes data validation prior to SC issuance.
The spark-ignition aircraft piston engine of the future
NASA Technical Reports Server (NTRS)
Stuckas, K. J.
1980-01-01
Areas of advanced technology appropriate to the design of a spark-ignition aircraft piston engine for the late 1980 time period were investigated and defined. Results of the study show that significant improvements in fuel economy, weight and size, safety, reliability, durability and performance may be achieved with a high degree of success, predicated on the continued development of advances in combustion systems, electronics, materials and control systems.
2014-08-01
technologies and processes to achieve a required level of confidence that software systems and services function in the intended manner. 1.3 Security Example...that took three high-voltage lines out of service and a software fail- ure (a race condition3) that disabled the computing service that notified the... service had failed. Instead of analyzing the details of the alarm server failure, the reviewers asked why the following software assurance claim had
Development and Testing of an Inflatable, Rigidizable Space Structure Experiment
2006-03-01
successful, including physical dimension, weight , and cost. Inflatable structures have the potential to achieve greater efficiency in all of these...potential for low cost, high mechanical packaging efficiency, deployment reliability and low weight (13). The term inflatable structure indicates that a...back-up inflation gas a necessity for long term success. This addition can be very costly in terms of volume, weight , and expense due to added or
Ashoori, Mohammad; Sereshki, Narges Adib
2011-01-01
Objective This study investigates the effect of social and token economy reinforcements on academic achievement of 9th grade boy students with intellectual disabilities in an experimental science class in Tehran Province. Method The method used for this study was experimental by pre-test, post- test with a control group. The boy students with intellectual disabilities from three junior high schools participated in this study. The sample consisted of thirty, 9th grade boy students with intellectual disabilities in the selected schools; the schools were chosen by the multi-stage cluster method. To measure the progress of students in the science class, a teacher made test and the Wechsler intelligence test for matching the groups for IQ were used. To ensure validity, the content validity criteria depended tests calculated by the Lashe method and teachers' perspective were used. The reliability coefficient was obtained by the reliability coefficient of related tests; the percent agreement method and the obtained data were analyzed using one-way variance analysis and Shefe prosecution test. Results The results showed that there was a significant increase in academic achievement of students with intellectual disabilities when using token economy than using social reinforcements compared with the control group. Also, when using social reinforcements, the academic achievement of students was more than the control group. Conclusion Token economy and social reinforcements increased the academic achievement of students with intellectual disabilities in the science class; and also the effect of token economy reinforcements was more than social reinforcements on the subjects. PMID:22952517
Johnston, Blair A; Coghill, David; Matthews, Keith; Steele, J Douglas
2015-01-01
Methylphenidate (MPH) is established as the main pharmacological treatment for patients with attention deficit hyperactivity disorder (ADHD). Whilst MPH is generally a highly effective treatment, not all patients respond, and some experience adverse reactions. Currently, there is no reliable method to predict how patients will respond, other than by exposure to a trial of medication. In this preliminary study, we sought to investigate whether an accurate predictor of clinical response to methylphenidate could be developed for individual patients, using sociodemographic, clinical and neuropsychological measures. Of the 43 boys with ADHD included in this proof-of-concept study, 30 were classed as responders and 13 as non-responders to MPH, with no significant differences in age nor verbal intelligence quotient (IQ) between the groups. Here we report the application of a multivariate analysis approach to the prediction of clinical response to MPH, which achieved an accuracy of 77% (p = 0.005). The most important variables to the classifier were performance on a 'go/no go' task and comorbid conduct disorder. This preliminary study suggested that further investigation is merited. Achieving a highly significant accuracy of 77% for the prediction of MPH response is an encouraging step towards finding a reliable and clinically useful method that could minimise the number of children needlessly being exposed to MPH. © The Author(s) 2014.
An energy-efficient rate adaptive media access protocol (RA-MAC) for long-lived sensor networks.
Hu, Wen; Chen, Quanjun; Corke, Peter; O'Rourke, Damien
2010-01-01
We introduce an energy-efficient Rate Adaptive Media Access Control (RA-MAC) algorithm for long-lived Wireless Sensor Networks (WSNs). Previous research shows that the dynamic and lossy nature of wireless communications is one of the major challenges to reliable data delivery in WSNs. RA-MAC achieves high link reliability in such situations by dynamically trading off data rate for channel gain. The extra gain that can be achieved reduces the packet loss rate which contributes to reduced energy expenditure through a reduced numbers of retransmissions. We achieve this at the expense of raw bit rate which generally far exceeds the application's link requirement. To minimize communication energy consumption, RA-MAC selects the optimal data rate based on the estimated link quality at each data rate and an analytical model of the energy consumption. Our model shows how the selected data rate depends on different channel conditions in order to minimize energy consumption. We have implemented RA-MAC in TinyOS for an off-the-shelf sensor platform (the TinyNode) on top of a state-of-the-art WSN Media Access Control Protocol, SCP-MAC, and evaluated its performance by comparing our implementation with the original SCP-MAC using both simulation and experiment.
Zuo, Xi-Nian; Xu, Ting; Jiang, Lili; Yang, Zhi; Cao, Xiao-Yan; He, Yong; Zang, Yu-Feng; Castellanos, F Xavier; Milham, Michael P
2013-01-15
While researchers have extensively characterized functional connectivity between brain regions, the characterization of functional homogeneity within a region of the brain connectome is in early stages of development. Several functional homogeneity measures were proposed previously, among which regional homogeneity (ReHo) was most widely used as a measure to characterize functional homogeneity of resting state fMRI (R-fMRI) signals within a small region (Zang et al., 2004). Despite a burgeoning literature on ReHo in the field of neuroimaging brain disorders, its test-retest (TRT) reliability remains unestablished. Using two sets of public R-fMRI TRT data, we systematically evaluated the ReHo's TRT reliability and further investigated the various factors influencing its reliability and found: 1) nuisance (head motion, white matter, and cerebrospinal fluid) correction of R-fMRI time series can significantly improve the TRT reliability of ReHo while additional removal of global brain signal reduces its reliability, 2) spatial smoothing of R-fMRI time series artificially enhances ReHo intensity and influences its reliability, 3) surface-based R-fMRI computation largely improves the TRT reliability of ReHo, 4) a scan duration of 5 min can achieve reliable estimates of ReHo, and 5) fast sampling rates of R-fMRI dramatically increase the reliability of ReHo. Inspired by these findings and seeking a highly reliable approach to exploratory analysis of the human functional connectome, we established an R-fMRI pipeline to conduct ReHo computations in both 3-dimensions (volume) and 2-dimensions (surface). Copyright © 2012 Elsevier Inc. All rights reserved.
The PedsQL 4.0 as a school population health measure: feasibility, reliability, and validity.
Varni, James W; Burwinkle, Tasha M; Seid, Michael
2006-03-01
The application of health-related quality of life (HRQOL) as a school population health measure may facilitate risk assessment and resource allocation, the tracking of student health at the school and district level, the identification of health disparities among schoolchildren, and the determination of health outcomes from interventions and policy decisions at the school, district, and county level. To determine the feasibility, reliability, and validity of the 23-item PedsQL 4.0 (Pediatric Quality of Life Inventory) Generic Core Scales as a school population health measure for children and adolescents. Survey conducted in 304 classes at 18 elementary schools, 4 middle schools, and 3 high schools within a large metropolitan school district. The PedsQL 4.0 Generic Core Scales (Physical, Emotional, Social, School Functioning) were completed by 2437 children ages 8-18 and 4227 parents of children ages 5-18. The PedsQL 4.0 evidenced minimal missing responses, achieved excellent reliability for the Total Scale Score (alpha = 0.89 child, 0.92, parent report), and distinguished between healthy children and children with chronic health conditions. The PedsQL 4.0 was related to indicators of socioeconomic status (SES) at the school and district level. The PedsQL School Functioning Scale was significantly correlated with standardized achievement scores based on the Stanford 9. The results demonstrate the feasibility, reliability and validity of the PedsQL 4.0 Generic Core Scales as a school population health measure. The implications of measuring HRQOL in schoolchildren at the school, district, and county level for identifying and ameliorating health disparities are discussed.
Multiple objective optimization in reliability demonstration test
Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang
2016-10-01
Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less
The development of a questionnaire to measure students' motivation towards science learning
NASA Astrophysics Data System (ADS)
Tuan, Hsiao-Lin; Chin, Chi-Chin; Shieh, Shyang-Horng
2005-06-01
The purpose of this study was to develop a questionnaire that measures students' motivation toward science learning (SMTSL). Six scales were developed: self-efficacy, active learning strategies, science learning value, performance goal, achievement goal, and learning environment stimulation. In total, 1407 junior high school students from central Taiwan, varying in grades, sex, and achievements, were selected by stratified random sampling to respond to the questionnaire. The Cronbach alpha for the entire questionnaire was 0.89; for each scale, alpha ranged from 0.70 to 0.89. There were significant correlations (p?<?0.01) of the SMTSL questionnaire with students' science attitudes (r?=?0.41), and with the science achievement test in previous and current semesters (rp?=?0.40 and rc?=?0.41). High motivators and low motivators showed a significant difference (p?<?0.01) on their SMTSL scores. Findings of the study confirmed the validity and reliability of the SMTSL questionnaire. Implications for using the SMTSL questionnaire in research and in class are discussed in the paper.
NASA Astrophysics Data System (ADS)
Okamoto, Shin-ichi; Maekawa, Kei-ichi; Kawashima, Yoshiyuki; Shiba, Kazutoshi; Sugiyama, Hideki; Inoue, Masao; Nishida, Akio
2015-04-01
High quality static random access memory (SRAM) for 40-nm embedded MONOS flash memory with split gate (SG-MONOS) was developed. Marginal failure, which results in threshold voltage/drain current tailing and outliers of SRAM transistors, occurs when using a conventional SRAM structure. These phenomena can be explained by not only gate depletion but also partial depletion and percolation path formation in the MOS channel. A stacked poly-Si gate structure can suppress these phenomena and achieve high quality SRAM without any defects in the 6σ level and with high affinity to the 40-nm SG-MONOS process was developed.
Giving Bigger Satellites a Boost
NASA Technical Reports Server (NTRS)
2000-01-01
Ultramet, Inc. has spurred a new process for producing rocket engine thrust chambers, through SBIR funding and the Glenn Research Center. High-temperature oxidation-resistant thruster materials are being produced in order to achieve high-temperature capability without sacrificing reliability. These thruster materials lead to an estimated three-percent improvement in propulsion system performance. To develop this material, Ultramet used a process called chemical vapor deposition (CVD). CVD involves heating precursors for metals, like iridium and rhenium, to temperatures at which they become gaseous. They are then deposited onto a mandrel, or spindle, layer-by-layer to produce high-density, highly resistant materials from the inside out.
ERIC Educational Resources Information Center
Pekrun, Reinhard; Goetz, Thomas; Frenzel, Anne C.; Barchfeld, Petra; Perry, Raymond P.
2011-01-01
Aside from test anxiety scales, measurement instruments assessing students' achievement emotions are largely lacking. This article reports on the construction, reliability, internal validity, and external validity of the Achievement Emotions Questionnaire (AEQ) which is designed to assess various achievement emotions experienced by students in…
ERIC Educational Resources Information Center
Destin, Mesmin
2013-01-01
Wealth and assets have a reliable positive relationship with the achievement outcomes of students. Various approaches to understanding student achievement may inform the understanding of how wealth seems to influence children's educational experiences. This paper describes several perspectives from the student achievement literature within the…
NASA Astrophysics Data System (ADS)
Hohil, Myron E.; Desai, Sachi V.; Bass, Henry E.; Chambers, Jim
2005-03-01
Feature extraction methods based on the discrete wavelet transform and multiresolution analysis are used to develop a robust classification algorithm that reliably discriminates between conventional and simulated chemical/biological artillery rounds via acoustic signals produced during detonation. Distinct characteristics arise within the different airburst signatures because high explosive warheads emphasize concussive and shrapnel effects, while chemical/biological warheads are designed to disperse their contents over large areas, therefore employing a slower burning, less intense explosive to mix and spread their contents. The ensuing blast waves are readily characterized by variations in the corresponding peak pressure and rise time of the blast, differences in the ratio of positive pressure amplitude to the negative amplitude, and variations in the overall duration of the resulting waveform. Unique attributes can also be identified that depend upon the properties of the gun tube, projectile speed at the muzzle, and the explosive burn rates of the warhead. In this work, the discrete wavelet transform is used to extract the predominant components of these characteristics from air burst signatures at ranges exceeding 2km. Highly reliable discrimination is achieved with a feedforward neural network classifier trained on a feature space derived from the distribution of wavelet coefficients and higher frequency details found within different levels of the multiresolution decomposition.
Hydrogen Fueling Station in Honolulu, Hawaii Feasibility Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porter Hill; Michael Penev
2014-08-01
The Department of Energy Hydrogen & Fuel Cells Program Plan (September 2011) identifies the use of hydrogen for government and fleet electric vehicles as a key step for achieving “reduced greenhouse gas emissions; reduced oil consumption; expanded use of renewable power …; highly efficient energy conversion; fuel flexibility …; reduced air pollution; and highly reliable grid-support.” This report synthesizes several pieces of existing information that can inform a decision regarding the viability of deploying a hydrogen (H2) fueling station at the Fort Armstrong site in Honolulu, Hawaii.
270V Battery Using COTS NiCd Cells For Manned Spacecraft
NASA Technical Reports Server (NTRS)
Darcy, Eric; Davies,Frank; Hummer, Leigh; Strangways, Brad
2002-01-01
A high power (>35 kW at 215V), low capacity (5.2 Ah), and compact (45L) NiCd battery was developed for the X-38 Crew Return Vehicle (CRV), which is an experimental version of the lifeboat for the International Space Station (ISS). A simple design and innovative approach using a commercial-off-the-shelf (COTS) NiCd cell design enabled the design, qualification, and production of 4 flight units of this highly reliable and safe spacecraft battery to be achieved rapidly (2 years) and cheaply ($13M).
High efficiency low cost monolithic module for SARSAT distress beacons
NASA Technical Reports Server (NTRS)
Petersen, Wendell C.; Siu, Daniel P.
1992-01-01
The program objectives were to develop a highly efficient, low cost RF module for SARSAT beacons; achieve significantly lower battery current drain, amount of heat generated, and size of battery required; utilize MMIC technology to improve efficiency, reliability, packaging, and cost; and provide a technology database for GaAs based UHF RF circuit architectures. Presented in viewgraph form are functional block diagrams of the SARSAT distress beacon and beacon RF module as well as performance goals, schematic diagrams, predicted performances, and measured performances for the phase modulator and power amplifier.
Monolithically Integrated High-β Nanowire Lasers on Silicon.
Mayer, B; Janker, L; Loitsch, B; Treu, J; Kostenbader, T; Lichtmannecker, S; Reichert, T; Morkötter, S; Kaniber, M; Abstreiter, G; Gies, C; Koblmüller, G; Finley, J J
2016-01-13
Reliable technologies for the monolithic integration of lasers onto silicon represent the holy grail for chip-level optical interconnects. In this context, nanowires (NWs) fabricated using III-V semiconductors are of strong interest since they can be grown site-selectively on silicon using conventional epitaxial approaches. Their unique one-dimensional structure and high refractive index naturally facilitate low loss optical waveguiding and optical recirculation in the active NW-core region. However, lasing from NWs on silicon has not been achieved to date, due to the poor modal reflectivity at the NW-silicon interface. We demonstrate how, by inserting a tailored dielectric interlayer at the NW-Si interface, low-threshold single mode lasing can be achieved in vertical-cavity GaAs-AlGaAs core-shell NW lasers on silicon as measured at low temperature. By exploring the output characteristics along a detection direction parallel to the NW-axis, we measure very high spontaneous emission factors comparable to nanocavity lasers (β = 0.2) and achieve ultralow threshold pump energies ≤11 pJ/pulse. Analysis of the input-output characteristics of the NW lasers and the power dependence of the lasing emission line width demonstrate the potential for high pulsation rates ≥250 GHz. Such highly efficient nanolasers grown monolithically on silicon are highly promising for the realization of chip-level optical interconnects.
Reliability enhancement of Ohmic RF MEMS switches
NASA Astrophysics Data System (ADS)
Kurth, Steffen; Leidich, Stefan; Bertz, Andreas; Nowack, Markus; Frömel, Jörg; Kaufmann, Christian; Faust, Wolfgang; Gessner, Thomas; Akiba, Akira; Ikeda, Koichi
2011-02-01
This contribution deals with capacitively actuated Ohmic switches in series single pole single throw (SPST) configuration for DC up to 4 GHz signal frequency (<0.5 dB insertion loss, 35 dB isolation) and in shunt switch SPST configuration for a frequency range from DC up to 80 GHz (<1.2 dB insertion loss, 18 dB isolation at 60 GHz). A novel high aspect ratio MEMS fabrication sequence in combination with wafer level packaging is applied for fabrication of the samples and allows for a relatively large actuation electrode area, and for high actuation force resulting in fast onresponse time of 10 μs and off-response time of 6 μs at less than 5 V actuation voltage. Large actuation electrode area and a particular design feature for electrode over travel and dynamic contact separation lead to high contact force in the closed state and to high force for contact separation to overcome sticking. The switch contacts, which are consisting of noble metal, are made in one of the latest process steps. This minimizes contamination of the contact surfaces by fabrication sequence residuals. A life time of 1 Billion switch cycles has been achieved. This paper covers design for reliability issues and reliability test methods using accelerated life time test. Different test methods are combined to examine electric and mechanical motion parameters as well as RF performance.
The next generation in aircraft protection against advanced MANPADS
NASA Astrophysics Data System (ADS)
Chapman, Stuart
2014-10-01
This paper discusses the advanced and novel technologies and underlying systems capabilities that Selex ES has applied during the development, test and evaluation of the twin head Miysis DIRCM System in order to ensure that it provides the requisite levels of protection against the latest, sophisticated all-aspect IR MANPADS. The importance of key performance parameters, including the fundamental need for "spherical" coverage, rapid time to energy-on-target, laser tracking performance and radiant intensity on seeker dome is covered. It also addresses the approach necessary to ensure that the equipment is suited to all air platforms from the smallest helicopters to large transports, while also ensuring that it achieves an inherent high reliability and an ease of manufacture and repair such that a step change in through-life cost in comparison to previous generation systems can be achieved. The benefits and issues associated with open architecture design are also considered. Finally, the need for extensive test and evaluation at every stage, including simulation, laboratory testing, platform and target dynamic testing in a System Integration Laboratory (SIL), flight trial, missile live-fire, environmental testing and reliability testing is also described.
Fuller, Joel T; Archer, Jane; Buckley, Jonathan D; Tsiros, Margarita D; Thewlis, Dominic
2016-01-01
To investigate the reliability of a simple, efficient technique for measuring bone mineral density (BMD) in the metatarsals using dual-energy X-ray absorptiometry (DXA). BMD of the right foot of 32 trained male distance runners was measured using a DXA scanner with the foot in the plantar position. Separate regions of interest (ROI) were used to assess the BMD of each metatarsal shaft (1st-5th) for each participant. ROI analysis was repeated by the same investigator to determine within-scan intra-rater reliability and by a different investigator to determine within-scan inter-rater reliability. Repeat DXA scans were undertaken for ten participants to assess between-scan intra-rater reliability. Assessment of BMD was consistently most reliable for the first metatarsal across all domains of reliability assessed (intra-class correlation coefficient [ICC] ≥0.97; coefficient of variation [CV] ≤1.5%; limits of agreement [LOA] ≤4.2%). Reasonable levels of intra-rater reliability were also achieved for the second and fifth metatarsals (ICC ≥0.90; CV ≤4.2%; LOA ≤11.9%). Poorer levels of reliability were demonstrated for the third (ICC ≥0.64; CV ≤8.2%; LOA ≤23.6%) and fourth metatarsals (ICC ≥0.67; CV ≤9.6%; LOA ≤27.5%). BMD was greatest in the first and second metatarsals (P < 0.01). Reliable measurements of BMD were achieved for the first, second and fifth metatarsals.
High power tests of an electroforming cavity operating at 11.424 GHz
NASA Astrophysics Data System (ADS)
Dolgashev, V. A.; Gatti, G.; Higashi, Y.; Leonardi, O.; Lewandowski, J. R.; Marcelli, A.; Rosenzweig, J.; Spataro, B.; Tantawi, S. G.; Yeremian, D. A.
2016-03-01
The achievement of ultra high accelerating gradients is mandatory in order to fabricate compact accelerators at 11.424 GHz for scientific and industrial applications. An extensive experimental and theoretical program to determine a reliable ultra high gradient operation of the future linear accelerators is under way in many laboratories. In particular, systematic studies on the 11.424 GHz frequency accelerator structures, R&D on new materials and the associated microwave technology are in progress to achieve accelerating gradients well above 120 MeV/m. Among the many, the electroforming procedure is a promising approach to manufacture high performance RF devices in order to avoid the high temperature brazing and to produce precise RF structures. We report here the characterization of a hard high gradient RF accelerating structure at 11.424 GHz fabricated using the electroforming technique. Low-level RF measurements and high power RF tests carried out at the SLAC National Accelerator Laboratory on this prototype are presented and discussed. In addition, we present also a possible layout where the water-cooling of irises based on the electroforming process has been considered for the first time.
Construction of Valid and Reliable Test for Assessment of Students
ERIC Educational Resources Information Center
Osadebe, P. U.
2015-01-01
The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…
High-brightness 9xxnm fiber coupled diode lasers
NASA Astrophysics Data System (ADS)
Liu, Rui; Jiang, Xiaochen; Yang, Thomas; He, Xiaoguang; Gao, Yanyan; Zhu, Jing; Zhang, Tujia; Guo, Weirong; Wang, Baohua; Guo, Zhijie; Zhang, Luyan; Chen, Louisa
2015-03-01
We developed a high brightness fiber coupled diode laser module providing more than 140W output power from a 105μm NA 0.15 fiber at the wavelength of 915nm.The high brightness module has an electrical to optical efficiency better than 45% and power enclosure more than 90% within NA 0.13. It is based on multi-single emitters using optical and polarization beam combining and fiber coupling technique. With the similar technology, over 100W of optical power into a 105μm NA 0.15 fiber at 976nm is also achieved which can be compatible with the volume Bragg gratings to receive narrow and stabilized spectral linewidth. The light within NA 0.12 is approximately 92%. The reliability test data of single and multiple single emitter laser module under high optical load are also presented and analyzed using a reliability model with an emitting aperture optimized for coupling into 105μm core fiber. The total MTTF shows exceeding 100,000 hours within 60% confidence level. The packaging processes and optical design are ready for commercial volume production.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Hongguang, E-mail: chenghg7932@gmail.com; Deng, Ning
2013-12-15
We investigated the influence of thermal agitation on the electric field induced precessional magnetization switching probability with perpendicular easy axis by solving the Fokker-Planck equation numerically with finite difference method. The calculated results show that the thermal agitation during the reversal process crucially influences the switching probability. The switching probability can be achieved is only determined by the thermal stability factor Δ of the free layer, it is independent on the device dimension, which is important for the high density device application. Ultra-low error rate down to the order of 10{sup −9} can be achieved for the device of thermalmore » stability factor Δ of 40. Low damping factor α material should be used for the free layer for high reliability device applications. These results exhibit potential of electric field induced precessional magnetization switching with perpendicular easy axis for ultra-low power, high speed and high density magnetic random access memory (MRAM) applications.« less
Fast response pyroelectric detector-preamplifier assembled device
NASA Astrophysics Data System (ADS)
Bai, PiJi; Tai, Yunjian; Liu, Huiping
2008-03-01
The pyroelectric detector is wide used for its simple structure and high performance to price ratio. It has been used in thermal detecting, infrared spectrum and laser testing. When the pyroelectric detector was applied in practice, fast reponse speed is need. For improving the response speed of the pyroelectric detector some specific technology has been used in the preamplifier schematic. High sense and fast response character of the pyroelectric detector-preamplifier assembled device had been achieved. When the device is applied in acute concussion condition, it must survive from the acute concussion condition testing. For it reliability some specific technology was used in the device fabricating procedure. At last the performance parameter testing result and simulation application condition result given in this paper show the performance of the pyroelectric detector-preamplifier assembled device had achieved the advance goal.
NASA Astrophysics Data System (ADS)
Seema; Chauhan, Sudakar Singh
2018-05-01
In this paper, we demonstrate the double gate vertical tunnel field-effect transistor using homo/hetero dielectric buried oxide (HDB) to obtain the optimized device characteristics. In this concern, the existence of double gate, HDB and electrode work-function engineering enhances DC performance and Analog/RF performance. The use of electrostatic doping helps to achieve higher on-current owing to occurrence of higher tunneling generation rate of charge carriers at the source/epitaxial interface. Further, lightly doped drain region and high- k dielectric below channel and drain region are responsible to suppress the ambipolar current. Simulated results clarifies that proposed device have achieved the tremendous performance in terms of driving current capability, steeper subthreshold slope (SS), drain induced barrier lowering (DIBL), hot carrier effects (HCEs) and high frequency parameters for better device reliability.
ADVANCEMENT OF THE RHIC BEAM ABORT KICKER SYSTEM.
DOE Office of Scientific and Technical Information (OSTI.GOV)
ZHANG,W.AHRENS,L.MI,J.OERTER,B.SANDBERG,J.WARBURTON,D.
2003-05-12
As one of the most critical system for RHIC operation, the beam abort kicker system has to be highly available, reliable, and stable for the entire operating range. Along with the RHIC commission and operation, consistent efforts have been spend to cope with immediate issues as well as inherited design issues. Major design changes have been implemented to achieve the higher operating voltage, longer high voltage hold-off time, fast retriggering and redundant triggering, and improved system protection, etc. Recent system test has demonstrated for the first time that both blue ring and yellow ring beam abort systems have achieved moremore » than 24 hours hold off time at desired operating voltage. In this paper, we report break down, thyratron reverse arcing, and to build a fast re-trigger system to reduce beam spreading in event of premature discharge.« less
Ort, Rebecca; Metzler, Philipp; Kruse, Astrid L.; Matthews, Felix; Zemann, Wolfgang; Grätz, Klaus W.; Luebbers, Heinz-Theo
2012-01-01
Ample data exists about the high precision of three-dimensional (3D) scanning devices and their data acquisition of the facial surface. However, a question remains regarding which facial landmarks are reliable if identified in 3D images taken under clinical circumstances. Sources of error to be addressed could be technical, user dependent, or patient respectively anatomy related. Based on clinical 3D photos taken with the 3dMDface system, the intra observer repeatability of 27 facial landmarks in six cleft lip (CL) infants and one non-CL infant was evaluated based on a total of over 1,100 measurements. Data acquisition was sometimes challenging but successful in all patients. The mean error was 0.86 mm, with a range of 0.39 mm (Exocanthion) to 2.21 mm (soft gonion). Typically, landmarks provided a small mean error but still showed quite a high variance in measurements, for example, exocanthion from 0.04 mm to 0.93 mm. Vice versa, relatively imprecise landmarks still provide accurate data regarding specific spatial planes. One must be aware of the fact that the degree of precision is dependent on landmarks and spatial planes in question. In clinical investigations, the degree of reliability for landmarks evaluated should be taken into account. Additional reliability can be achieved via multiple measuring. PMID:22919476
High Reliability Prototype Quadrupole for the Next Linear Collider
NASA Astrophysics Data System (ADS)
Spencer, C. M.
2001-01-01
The Next Linear Collider (NLC) will require over 5600 magnets, each of which must be highly reliable and/or quickly repairable in order that the NLC reach its 85/ overall availability goal. A multidiscipline engineering team was assembled at SLAC to develop a more reliable electromagnet design than historically had been achieved at SLAC. This team carried out a Failure Mode and Effects Analysis (FMEA) on a standard SLAC quadrupole magnet system. They overcame a number of longstanding design prejudices, producing 10 major design changes. This paper describes how a prototype magnet was constructed and the extensive testing carried out on it to prove full functionality with an improvement in reliability. The magnet's fabrication cost will be compared to the cost of a magnet with the same requirements made in the historic SLAC way. The NLC will use over 1600 of these 12.7 mm bore quadrupoles with a range of integrated strengths from 0.6 to 132 Tesla, a maximum gradient of 135 Tesla per meter, an adjustment range of 0 to -20/ and core lengths from 324 mm to 972 mm. The magnetic center must remain stable to within 1 micron during the 20/ adjustment. A magnetic measurement set-up has been developed that can measure sub-micron shifts of a magnetic center. The prototype satisfied the center shift requirement over the full range of integrated strengths.
NASA Technical Reports Server (NTRS)
Tai, Ann T.; Chau, Savio N.; Alkalai, Leon
2000-01-01
Using COTS products, standards and intellectual properties (IPs) for all the system and component interfaces is a crucial step toward significant reduction of both system cost and development cost as the COTS interfaces enable other COTS products and IPs to be readily accommodated by the target system architecture. With respect to the long-term survivable systems for deep-space missions, the major challenge for us is, under stringent power and mass constraints, to achieve ultra-high reliability of the system comprising COTS products and standards that are not developed for mission-critical applications. The spirit of our solution is to exploit the pertinent standard features of a COTS product to circumvent its shortcomings, though these standard features may not be originally designed for highly reliable systems. In this paper, we discuss our experiences and findings on the design of an IEEE 1394 compliant fault-tolerant COTS-based bus architecture. We first derive and qualitatively analyze a -'stacktree topology" that not only complies with IEEE 1394 but also enables the implementation of a fault-tolerant bus architecture without node redundancy. We then present a quantitative evaluation that demonstrates significant reliability improvement from the COTS-based fault tolerance.
Efficient Network Coding-Based Loss Recovery for Reliable Multicast in Wireless Networks
NASA Astrophysics Data System (ADS)
Chi, Kaikai; Jiang, Xiaohong; Ye, Baoliu; Horiguchi, Susumu
Recently, network coding has been applied to the loss recovery of reliable multicast in wireless networks [19], where multiple lost packets are XOR-ed together as one packet and forwarded via single retransmission, resulting in a significant reduction of bandwidth consumption. In this paper, we first prove that maximizing the number of lost packets for XOR-ing, which is the key part of the available network coding-based reliable multicast schemes, is actually a complex NP-complete problem. To address this limitation, we then propose an efficient heuristic algorithm for finding an approximately optimal solution of this optimization problem. Furthermore, we show that the packet coding principle of maximizing the number of lost packets for XOR-ing sometimes cannot fully exploit the potential coding opportunities, and we then further propose new heuristic-based schemes with a new coding principle. Simulation results demonstrate that the heuristic-based schemes have very low computational complexity and can achieve almost the same transmission efficiency as the current coding-based high-complexity schemes. Furthermore, the heuristic-based schemes with the new coding principle not only have very low complexity, but also slightly outperform the current high-complexity ones.
Rapid Modeling and Analysis Tools: Evolution, Status, Needs and Directions
NASA Technical Reports Server (NTRS)
Knight, Norman F., Jr.; Stone, Thomas J.; Ransom, Jonathan B. (Technical Monitor)
2002-01-01
Advanced aerospace systems are becoming increasingly more complex, and customers are demanding lower cost, higher performance, and high reliability. Increased demands are placed on the design engineers to collaborate and integrate design needs and objectives early in the design process to minimize risks that may occur later in the design development stage. High performance systems require better understanding of system sensitivities much earlier in the design process to meet these goals. The knowledge, skills, intuition, and experience of an individual design engineer will need to be extended significantly for the next generation of aerospace system designs. Then a collaborative effort involving the designer, rapid and reliable analysis tools and virtual experts will result in advanced aerospace systems that are safe, reliable, and efficient. This paper discusses the evolution, status, needs and directions for rapid modeling and analysis tools for structural analysis. First, the evolution of computerized design and analysis tools is briefly described. Next, the status of representative design and analysis tools is described along with a brief statement on their functionality. Then technology advancements to achieve rapid modeling and analysis are identified. Finally, potential future directions including possible prototype configurations are proposed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aydin, Süleyman, E-mail: yupul@hotmail.com; Haşiloğlu, M. Akif, E-mail: mehmet.hasiloglu@hotmail.com; Kunduraci, Ayşe, E-mail: ayse-kndrc@hotmail.com
In this study it was aimed to improve an academic achievement test to establish the students’ knowledge about the earthquake and the ways of protection from earthquakes. In the method of this study, the steps that Webb (1994) was created to improve an academic achievement test for a unit were followed. In the developmental process of multiple choice test having 25 questions, was prepared to measure the pre-service teachers’ knowledge levels about the earthquake and the ways of protection from earthquakes. The multiple choice test was presented to view of six academics (one of them was from geographic field andmore » five of them were science educator) and two expert teachers in science Prepared test was applied to 93 pre-service teachers studying in elementary education department in 2014-2015 academic years. As a result of validity and reliability of the study, the test was composed of 20 items. As a result of these applications, Pearson Moments Multiplication half-reliability coefficient was found to be 0.94. When this value is adjusted according to Spearman Brown reliability coefficient the reliability coefficient was set at 0.97.« less
Evaluation of changes in pelvic belt tension during 2 weight-bearing functional tasks.
Arumugam, Ashokan; Milosavljevic, Stephan; Woodley, Stephanie; Sole, Gisela
2012-06-01
The purposes of this study were to evaluate changes in pelvic belt tension during 2 weight-bearing functional tasks (transition from bipedal to unipedal stance [BUS] and walking) and to evaluate the reliability and the percentage variation for belt tension scores from trial to trial. A cross-sectional repeated-measures study was conducted with 10 healthy male participants (mean age, 28.3 ± 8.8years). Participants performed 10 trials of BUS and walking while wearing a nonelastic pelvic compression belt (PCB) applied distal to the anterior superior iliac spines, with a load cell positioned in the center of the belt. The load cell was calibrated using known weights (1-10kg) to define the relationship between the applied tension and voltage change (R(2) = 0.99). Load cell tension values were recorded in voltage signals and then converted to newtons of force using appropriate conversion values (0.012V = 10N). Mean and standard deviation values, intraclass correlation coefficients (ICC 3,1), and percentage standard error of measurements (% SEM) were analyzed for PCB tension recorded during the BUS and walking trials. The mean tension achieved with a PCB was found to be 41.02 (±4.23) N during BUS and 44.07 (±5.80) N during walking. The trial-to-trial reliability (ICC 3,1) was high (ICC ≥0.9), and the variation in PCB tension across 10 trials (% SEM) was 4% or less. The mean tension achieved during the tasks was 44 N or less. The reliability is high, and the variation is low across the trials, which implies that a PCB could be used to produce consistent effects during repetition of the tasks (BUS and walking). Copyright © 2012 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Cryogenic Multichannel Pressure Sensor With Electronic Scanning
NASA Technical Reports Server (NTRS)
Hopson, Purnell, Jr.; Chapman, John J.; Kruse, Nancy M. H.
1994-01-01
Array of pressure sensors operates reliably and repeatably over wide temperature range, extending from normal boiling point of water down to boiling point of nitrogen. Sensors accurate and repeat to within 0.1 percent. Operate for 12 months without need for recalibration. Array scanned electronically, sensor readings multiplexed and sent to desktop computer for processing and storage. Used to measure distributions of pressure in research on boundary layers at high Reynolds numbers, achieved by low temperatures.
Robust Tensioned Kevlar Suspension Design
NASA Technical Reports Server (NTRS)
Young, Joseph B.; Naylor, Bret J.; Holmes, Warren A.
2012-01-01
One common but challenging problem in cryogenic engineering is to produce a mount that has excellent thermal isolation but is also rigid. Such mounts can be achieved by suspending the load from a network of fibers or strings held in tension. Kevlar fibers are often used for this purpose owing to their high strength and low thermal conductivity. A suite of compact design elements has been developed to improve the reliability of suspension systems made of Kevlar.
Energy Storage Technology Development for Space Exploration
NASA Technical Reports Server (NTRS)
Mercer, Carolyn R.; Jankovsky, Amy L.; Reid, Concha M.; Miller, Thomas B.; Hoberecht, Mark A.
2011-01-01
The National Aeronautics and Space Administration is developing battery and fuel cell technology to meet the expected energy storage needs of human exploration systems. Improving battery performance and safety for human missions enhances a number of exploration systems, including un-tethered extravehicular activity suits and transportation systems including landers and rovers. Similarly, improved fuel cell and electrolyzer systems can reduce mass and increase the reliability of electrical power, oxygen, and water generation for crewed vehicles, depots and outposts. To achieve this, NASA is developing non-flow-through proton-exchange-membrane fuel cell stacks, and electrolyzers coupled with low permeability membranes for high pressure operation. The primary advantage of this technology set is the reduction of ancillary parts in the balance-of-plant fewer pumps, separators and related components should result in fewer failure modes and hence a higher probability of achieving very reliable operation, and reduced parasitic power losses enable smaller reactant tanks and therefore systems with lower mass and volume. Key accomplishments over the past year include the fabrication and testing of several robust, small-scale non-flow-through fuel cell stacks that have demonstrated proof-of-concept. NASA is also developing advanced lithium-ion battery cells, targeting cell-level safety and very high specific energy and energy density. Key accomplishments include the development of silicon composite anodes, lithiatedmixed- metal-oxide cathodes, low-flammability electrolytes, and cell-incorporated safety devices that promise to substantially improve battery performance while providing a high level of safety.
Reliability Assessment Approach for Stirling Convertors and Generators
NASA Technical Reports Server (NTRS)
Shah, Ashwin R.; Schreiber, Jeffrey G.; Zampino, Edward; Best, Timothy
2004-01-01
Stirling power conversion is being considered for use in a Radioisotope Power System for deep-space science missions because it offers a multifold increase in the conversion efficiency of heat to electric power. Quantifying the reliability of a Radioisotope Power System that utilizes Stirling power conversion technology is important in developing and demonstrating the capability for long-term success. A description of the Stirling power convertor is provided, along with a discussion about some of the key components. Ongoing efforts to understand component life, design variables at the component and system levels, related sources, and the nature of uncertainties is discussed. The requirement for reliability also is discussed, and some of the critical areas of concern are identified. A section on the objectives of the performance model development and a computation of reliability is included to highlight the goals of this effort. Also, a viable physics-based reliability plan to model the design-level variable uncertainties at the component and system levels is outlined, and potential benefits are elucidated. The plan involves the interaction of different disciplines, maintaining the physical and probabilistic correlations at all the levels, and a verification process based on rational short-term tests. In addition, both top-down and bottom-up coherency were maintained to follow the physics-based design process and mission requirements. The outlined reliability assessment approach provides guidelines to improve the design and identifies governing variables to achieve high reliability in the Stirling Radioisotope Generator design.
Kilgus, Stephen P; Riley-Tillman, T Chris; Stichter, Janine P; Schoemann, Alexander M; Bellesheim, Katie
2016-09-01
The purpose of this investigation was to evaluate the reliability of Direct Behavior Ratings-Social Competence (DBR-SC) ratings. Participants included 60 students identified as possessing deficits in social competence, as well as their 23 classroom teachers. Teachers used DBR-SC to complete ratings of 5 student behaviors within the general education setting on a daily basis across approximately 5 months. During this time, each student was assigned to 1 of 2 intervention conditions, including the Social Competence Intervention-Adolescent (SCI-A) and a business-as-usual (BAU) intervention. Ratings were collected across 3 intervention phases, including pre-, mid-, and postintervention. Results suggested DBR-SC ratings were highly consistent across time within each student, with reliability coefficients predominantly falling in the .80 and .90 ranges. Findings further indicated such levels of reliability could be achieved with only a small number of ratings, with estimates varying between 2 and 10 data points. Group comparison analyses further suggested the reliability of DBR-SC ratings increased over time, such that student behavior became more consistent throughout the intervention period. Furthermore, analyses revealed that for 2 of the 5 DBR-SC behavior targets, the increase in reliability over time was moderated by intervention grouping, with students receiving SCI-A demonstrating greater increases in reliability relative to those in the BAU group. Limitations of the investigation as well as directions for future research are discussed herein. (PsycINFO Database Record (c) 2016 APA, all rights reserved).
The Advanced Gamma-ray Imaging System (AGIS): Focal Plane Detectors
NASA Astrophysics Data System (ADS)
Mukherjee, Reshmi; Byrum, K.; Drake, G.; Falcone, A.; Funk, S.; Horan, D.; Tajima, H.; Wagner, B.; Williams, D.
2008-04-01
Report of the Focal Plane Instrumentation Working Group, AGIS collaboration: The Advanced Gamma-ray Imaging System (AGIS) is a concept for the next generation instrument in ground-based very high energy gamma-ray astronomy. It has the goal of achieving significant improvement in sensitivity over current experiments. One of the main requirements for AGIS will be to achieve higher angular resolution than current imaging atmospheric Cherenkov telescopes (IACTs). Simulations show that a substantial improvement in angular resolution may be achieved if the pixel size is reduced to 0.05 deg, below that of current IACTs. Reducing the cost per channel and improving reliability and modularity are other important considerations. Here we present several alternatives being considered for AGIS, including both silicon photomultipliers (SiPMs) and multi-anode photomultipliers (MAPMTs) and summarize results from feasibility testing by various AGIS photodetector group members.
Non-Toxic Reaction Control System for the Reusable First Stage Vehicle
NASA Technical Reports Server (NTRS)
Keith, E. L.; Rothschild, W. J.
1999-01-01
This paper presents the Boeing Reusable Space Systems vision of a Reaction Control System (RCS) for the Reusable First Stage (RFS) being considered as a replacement for the Solid Rocket Booster for the Space Shuttle. The requirement is to achieve reliable vehicle control during the upper atmospheric portion of the RFS trajectory while enabling more efficient ground operations, unhindered by constraints caused by operating with highly toxic RCS propellants. Boeing's objective for this effort is to develop a safer, more efficient and environmentally friendly RCS design approach that is suitable for the RFS concept of operations, including a low cost, efficient turnaround cycle. The Boeing RCS concept utilizes ethanol and liquid oxygen in place of the highly toxic, suspected carcinogen, ozone-depleting mono-methyl-hydrazine and highly toxic nitrogen tetroxide. The Space Shuttle Upgrade program, under the leadership of the NASA Johnson Space Flight Center, is currently developing liquid oxygen and ethanol (ethyl alcohol) technology for use as non-toxic orbital maneuvering system (OMS) and RCS. The development of this liquid oxygen and ethanol technology for the Space Shuttle offers a significant leverage to select much of the same technology for the RFS program. There are significant design and development issues involved with bringing this liquid oxygen and ethanol technology to a state of maturity suitable for an operational RCS. The risks associated with a new LOX and Ethanol RCS are mitigated by maintaining kerosene and hydrogen peroxide RCS technology as an alternative. These issues, presented within this paper, include managing the oxygen supply and achieving reliable ignition in the short pulse mode of engine operation. Performance, reliability and operations requirements are presented along with a specific RCS design concept to satisfying these requirements. The work reported in this paper was performed under NASA Marshall Space Flight Center Contract Number NAS8-97272 to define Reusable First Stage design concepts for the Space Shuttle.
Non-Toxic Reaction Control System for the Reusable First Stage Vehicle
NASA Technical Reports Server (NTRS)
Keith, E. L.; Rothschild, W. J.
1999-01-01
This paper presents the Boeing Reusable Space Systems vision of a Reaction Control System (RCS) for the Reusable First Stage (RFS) being considered as a replacement for the Solid Rocket Booster for the Space Shuttle. The requirement is to,achieve reliable vehicle control during the upper atmospheric portion of the RFS trajectory while enabling more efficient ground operations, unhindered by constraints caused by operating with highly toxic RCS propellants. Boeing's objective for this effort is to develop a safer, more efficient and environmentally friendly RCS design approach that is suitable for the RFS concept of operations, including a low cost, efficient turnaround cycle. The Boeing RCS concept utilizes ethanol and liquid oxygen in place of the highly toxic, suspected carcinogen, ozone- depleting mono-methyl-hydrazine and highly toxic nitrogen tetroxide. The Space Shuttle Upgrade program, under the leadership of the NASA Johnson Space Flight Center, is currently developing liquid oxygen and ethanol (ethyl alcohol) technology for use as non-toxic orbital maneuvering system (OMS) and RCS. The development of this liquid oxygen and ethanol technology for the Space Shuffle offers a significant leverage to select much of the same technology for the RFS program. There are significant design and development issues involved with bringing this liquid oxygen and ethanol technology to a state of maturity suitable for an operational RCS, The risks associated with a new LOX and Ethanol RCS are mitigated by maintaining kerosene and hydrogen peroxide RCS technology as an alternative. These issues, presented within this paper, include managing the oxygen supply and achieving reliable ignition in the short pulse mode of engine operation. Performance, reliability and operations requirements are presented along with a specific RCS design concept to satisfying these requirements. The work reported in this paper was performed under NASA Marshall Space Flight Center Contract to define Reusable First Stage design concepts for the Space Shuttle.
Leung, Sau Fong; Lee, Ka Li; Lee, Sze Man; Leung, Sik Chi; Hung, Wing Sze; Lee, Wai Leng; Leung, Yuen Yee; Li, Man Wai; Tse, Tak Kin; Wong, Hoi Kei; Wong, Yuen Ni
2009-02-01
Eating disorders are affecting an increasing number of high school students in Western and Asian countries. The availability of an effective screening tool is crucial for early detection and prompt intervention. The objective of this study was to examine the validity and reliability of the SCOFF questionnaire for screening eating disorders in Hong Kong high school students. This study adopted a cross-sectional design to examine the psychometric properties of the SCOFF questionnaire. A panel of 7 experts and 936 students of a high school participated in the study. The SCOFF questionnaire was translated into Chinese and back-translated into English to ensure the linguistic equivalence. A panel of 7 experts involved in the content validation of the SCOFF questionnaire. The Eating Disorder Examination-Questionnaire (EDE-Q) was used as the "reference standard" to assess its concurrent validity in 936 students of a high school. Its reliability was examined by internal consistency and the test-retest method at a 2-week interval and with 38 students. The SCOFF questionnaire achieved an agreement of 86-100% among the experts for the content relevance. Of 812 students (86.8%) who responded to this study, their SCOFF scores correlated significantly with their global scores on the EDE-Q (r=0.5, P<0.01). Students identified as potentially having eating disorders had significantly higher scores in the EDE-Q than those not identified as such by SCOFF. The SCOFF questionnaire demonstrated moderate test-retest reliability (ICC=0.66) and an acceptable internal consistency reliability (Cronbach's alpha=0.44-0.57) in comparing with previous studies. The SCOFF questionnaire has acceptable psychometric properties in the Chinese culture. It will be useful for detecting potential eating disorders and assisting health promotion activity.
Boles, Richard E; Burdell, Alexandra; Johnson, Susan L; Gavin, William J; Davies, Patricia L; Bellows, Laura L
2014-09-01
The purpose of this study was to refine and psychometrically test an instrument measuring the home food and activity environment of geographically and economically diverse families of preschool aged children. Caregivers of preschool aged children (n = 83) completed a modified self-report questionnaire. Reliably trained researchers conducted independent observations on 25 randomly selected homes. Agreement statistics were conducted at the item level (154 total items) to determine reliability. Frequency counts were calculated to identify item availability. Results showed Kappa statistics were high (.67-1.00) between independent researchers but varied between researchers and parents resulting in 85 items achieving criterion validity (Kappa >.60). Analyses of reliable items revealed the presence in the home of a high frequency of unhealthy snack foods, high fat milk and low frequency of availability of fruits/vegetables and low fat milk. Fifty-two percent of the homes were arranged with a television in the preschool child's bedroom. Physical Activity devices also were found to have high frequency availability. Families reporting lower education reported higher levels of sugar sweetened beverages and less low-fat dairy (p < .05) compared with higher education families. Low-income families (<$27K per year) reported significantly fewer Physical Activity devices (p < .001) compared with higher income families. Hispanic families reported significantly higher numbers of Sedentary Devices (p < .05) compared with non-Hispanic families. There were no significant differences between demographic comparisons on available fruits/vegetables, meats, whole grains, and regular fat dairy. A modified home food and activity instrument was found to reliably identify foods and activity devices with geographically and economically diverse families. Copyright © 2014 Elsevier Ltd. All rights reserved.
Ladova, Katerina; Matoulkova, Petra; Zadak, Zdenek; Macek, Karel; Vyroubal, Pavel; Vlcek, Jiri; Morisky, Donald E
2014-10-01
Measuring self-reported adherence may contribute to minimizing the risk of therapy failure. Hence, the main aim of the study was to assess the psychometric properties of the Czech version of Medication Adherence Report Scale (MARS-CZ) and its appropriateness for use in long-term statin therapy where goal levels of low-density lipoprotein cholesterol (LDL-c) should be achieved. Anonymous structured interview was performed to determine self-reported adherence by MARS-CZ in outpatients chronically treated with statins. At the same time, medication records were reviewed for inclusion of patients into groups of those who achieved and do not achieved LDL-c goal according to cardiovascular risk level. Reliability and validity of MARS-CZ were tested as well as the relationship between adherence and LDL-c goal achievement was examined. A total of 136 (86.6%) patients completed the interview; mean age was 66.1 years; 49.3% were male. The mean score of MARS-CZ was 24.4 and showed positive skewing. Satisfactory internal consistency (Cronbach's α=0.54), strong test-retest reliability (r=0.83, P<0.001; intra-class correlation=0.63, 95% confidence interval: 0.35-0.81) and positive correlation with eight-item Morisky Medication Adherence Scale (r=0.62, P<0.001) were indicated. Low validity values were found between MARS-CZ and 12-item Short Form Health Survey mental and physical subscales. MARS-CZ score significantly correlated with LDL-c goal achievement (P<0.05) when all patients who achieved LDL-c goal (35%) reported high adherence to statin. MARS-CZ score also correlated with cardiovascular risk level and doctor's judgments on adjusting treatment targets for each patient. This study proved MARS-CZ as an acceptable self-reported adherence measure. In routine clinical practice, MARS-CZ could be helpful to reveal medication non-adherence before the alteration of drug regimen and thereby contributing to enhancement of statin therapy management. © 2014 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Kulkarni, R. D.; Agarwal, Vivek
2008-08-01
An ion chamber amplifier (ICA) is used as a safety device for neutronic power (flux) measurement in regulation and protection systems of nuclear reactors. Therefore, performance reliability of an ICA is an important issue. Appropriate quality engineering is essential to achieve a robust design and performance of the ICA circuit. It is observed that the low input bias current operational amplifiers used in the input stage of the ICA circuit are the most critical devices for proper functioning of the ICA. They are very sensitive to the gamma radiation present in their close vicinity. Therefore, the response of the ICA deteriorates with exposure to gamma radiation resulting in a decrease in the overall reliability, unless desired performance is ensured under all conditions. This paper presents a performance enhancement scheme for an ICA operated in the nuclear environment. The Taguchi method, which is a proven technique for reliability enhancement, has been used in this work. It is demonstrated that if a statistical, optimal design approach, like the Taguchi method is used, the cost of high quality and reliability may be brought down drastically. The complete methodology and statistical calculations involved are presented, as are the experimental and simulation results to arrive at a robust design of the ICA.
Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.
Taylor, Karen; Bulsara, Max; Monterosso, Leanne
2018-01-01
Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.
Reliability of bounce drop jump parameters within elite male rugby players.
Costley, Lisa; Wallace, Eric; Johnston, Michael; Kennedy, Rodney
2017-07-25
The aims of the study were to investigate the number of familiarisation sessions required to establish reliability of the bounce drop jump (BDJ) and subsequent reliability once familiarisation is achieved. Seventeen trained male athletes completed 4 BDJs in 4 separate testing sessions. Force-time data from a 20 cm BDJ was obtained using two force plates (ensuring ground contact < 250 ms). Subjects were instructed to 'jump for maximal height and minimal contact time' while the best and average of four jumps were compared. A series of performance variables were assessed in both eccentric and concentric phases including jump height, contact time, flight time, reactive strength index (RSI), peak power, rate of force development (RFD) and actual dropping height (ADH). Reliability was assessed using the intraclass correlation coefficient (ICC) and coefficient of variation (CV) while familiarisation was assessed using a repeated measures analysis of variance (ANOVA). The majority of DJ parameters exhibited excellent reliability with no systematic bias evident, while the average of 4 trials provided greater reliability. With the exception of vertical stiffness (CV: 12.0 %) and RFD (CV: 16.2 %) all variables demonstrated low within subject variation (CV range: 3.1 - 8.9 %). Relative reliability was very poor for ADH, with heights ranging from 14.87 - 29.85 cm. High levels of reliability can be obtained from the BDJ with the exception of vertical stiffness and RFD, however, extreme caution must be taken when comparing DJ results between individuals and squads due to large discrepancies between actual drop height and platform height.
Novel MRF fluid for ultra-low roughness optical surfaces
NASA Astrophysics Data System (ADS)
Dumas, Paul; McFee, Charles
2014-08-01
Over the past few years there have been an increasing number of applications calling for ultra-low roughness (ULR) surfaces. A critical demand has been driven by EUV optics, EUV photomasks, X-Ray, and high energy laser applications. Achieving ULR results on complex shapes like aspheres and X-Ray mirrors is extremely challenging with conventional polishing techniques. To achieve both tight figure and roughness specifications, substrates typically undergo iterative global and local polishing processes. Typically the local polishing process corrects the figure or flatness but cannot achieve the required surface roughness, whereas the global polishing process produces the required roughness but degrades the figure. Magnetorheological Finishing (MRF) is a local polishing technique based on a magnetically-sensitive fluid that removes material through a shearing mechanism with minimal normal load, thus removing sub-surface damage. The lowest surface roughness produced by current MRF is close to 3 Å RMS. A new ULR MR fluid uses a nano-based cerium as the abrasive in a proprietary aqueous solution, the combination of which reliably produces under 1.5Å RMS roughness on Fused Silica as measured by atomic force microscopy. In addition to the highly convergent figure correction achieved with MRF, we show results of our novel MR fluid achieving <1.5Å RMS roughness on fused silica and other materials.
NASA Astrophysics Data System (ADS)
Vadivel, R.; Bhaskaran, V. Murali
2010-10-01
The main reason for packet loss in ad hoc networks is the link failure or node failure. In order to increase the path stability, it is essential to distinguish and moderate the failures. By knowing individual link stability along a path, path stability can be identified. In this paper, we develop an adaptive reliable routing protocol using combined link stability estimation for mobile ad hoc networks. The main objective of this protocol is to determine a Quality of Service (QoS) path along with prolonging the network life time and to reduce the packet loss. We calculate a combined metric for a path based on the parameters Link Expiration Time, Node Remaining Energy and Node Velocity and received signal strength to predict the link stability or lifetime. Then, a bypass route is established to retransmit the lost data, when a link failure occurs. By simulation results, we show that the proposed reliable routing protocol achieves high delivery ratio with reduced delay and packet drop.
Gong, Ang; Zhao, Xiubin; Pang, Chunlei; Duan, Rong; Wang, Yong
2015-12-02
For Global Navigation Satellite System (GNSS) single frequency, single epoch attitude determination, this paper proposes a new reliable method with baseline vector constraint. First, prior knowledge of baseline length, heading, and pitch obtained from other navigation equipment or sensors are used to reconstruct objective function rigorously. Then, searching strategy is improved. It substitutes gradually Enlarged ellipsoidal search space for non-ellipsoidal search space to ensure correct ambiguity candidates are within it and make the searching process directly be carried out by least squares ambiguity decorrelation algorithm (LAMBDA) method. For all vector candidates, some ones are further eliminated by derived approximate inequality, which accelerates the searching process. Experimental results show that compared to traditional method with only baseline length constraint, this new method can utilize a priori baseline three-dimensional knowledge to fix ambiguity reliably and achieve a high success rate. Experimental tests also verify it is not very sensitive to baseline vector error and can perform robustly when angular error is not great.
Hao, Xiao-ting; Wong, Irina S M; Kwan, Patrick
2011-10-01
We evaluated the interrater reliability of the consensus definition of drug-resistant epilepsy proposed by the International League Against Epilepsy. According to the definition framework, outcome of each antiepileptic drug (AED) trial was categorized as "seizure freedom" or "treatment failure." This level 1 assessment was used to determine the level 2 classification, which defined drug-resistant epilepsy as the failure of adequate trials of two or more AED schedules to achieve sustained seizure freedom. Two raters classified treatment outcomes of 150 patients independently. The patients had received a total of 428 trials of AEDs. Categorization of level 1 outcome to individual AED trials by the raters was consistent in 413 (96.5%). For the level 2 classification of drug-resistant or drug-responsive epilepsy, there was absolute agreement between the raters in 141 patients (94%), with a κ index of 0.91 (P<0.001). The definition appeared to have a high degree of interrater reliability in this setting. Copyright © 2011 Elsevier Inc. All rights reserved.
Parallelized reliability estimation of reconfigurable computer networks
NASA Technical Reports Server (NTRS)
Nicol, David M.; Das, Subhendu; Palumbo, Dan
1990-01-01
A parallelized system, ASSURE, for computing the reliability of embedded avionics flight control systems which are able to reconfigure themselves in the event of failure is described. ASSURE accepts a grammar that describes a reliability semi-Markov state-space. From this it creates a parallel program that simultaneously generates and analyzes the state-space, placing upper and lower bounds on the probability of system failure. ASSURE is implemented on a 32-node Intel iPSC/860, and has achieved high processor efficiencies on real problems. Through a combination of improved algorithms, exploitation of parallelism, and use of an advanced microprocessor architecture, ASSURE has reduced the execution time on substantial problems by a factor of one thousand over previous workstation implementations. Furthermore, ASSURE's parallel execution rate on the iPSC/860 is an order of magnitude faster than its serial execution rate on a Cray-2 supercomputer. While dynamic load balancing is necessary for ASSURE's good performance, it is needed only infrequently; the particular method of load balancing used does not substantially affect performance.
Advanced high-temperature batteries
NASA Technical Reports Server (NTRS)
Nelson, Paul A.
1989-01-01
The promise of very high specific energy and power was not yet achieved for practical battery systems. Some recent approaches are discussed for new approaches to achieving high performance for lithium/DeS2 cells and sodium/metal chloride cells. The main problems for the development of successful LiAl/FeS2 cells were the instability of the FeS2 electrode, which has resulted in rapidly declining capacity, the lack of an internal mechanism for accommodating overcharge of a cell, thus requiring the use of external charge control on each individual cell, and the lack of a suitable current collector for the positive electrode other than expensive molybdenum sheet material. Much progress was made in solving the first two problems. Reduction of the operating temperatures to 400 C by a change in electrolyte composition has increased the expected life to 1000 cycles. Also, a lithium shuttle mechanism was demonstrated for selected electrode compositions that permits sufficient overcharge tolerance to adjust for the normally expected cell-to-cell deviation in coulombic efficiency. Sodium/sulfur batteries and sodium/metal chloride batteries have demonstrated good reliability and long cycle life. For applications where very high power is desired, new electrolyte coinfigurations would be required. Design work was carried out for the sodium/metal chloride battery that demonstrates the feasibility of achieving high specific energy and high power for large battery cells having thin-walled high-surface area electrolytes.
NASA Astrophysics Data System (ADS)
Melgaard, Seth D.; Seletskiy, Denis V.; Di Lieto, Alberto; Tonelli, Mauro; Sheik-Bahae, Mansoor
2012-03-01
Since recent demonstration of cryogenic optical refrigeration, a need for reliable characterization tools of cooling performance of different materials is in high demand. We present our experimental apparatus that allows for temperature and wavelength dependent characterization of the materials' cooling efficiency and is based on highly sensitive spectral differencing technique or two-band differential spectral metrology (2B-DSM). First characterization of a 5% w.t. ytterbium-doped YLF crystal showed quantitative agreement with the current laser cooling model, as well as measured a minimum achievable temperature (MAT) at 110 K. Other materials and ion concentrations are also investigated and reported here.
Development and evaluation of superconducting circuit elements
NASA Technical Reports Server (NTRS)
Haertling, Gene H.; Lee, Burtrand; Hsi, Dennis; Modi, Vibhakar; Marone, Matt
1990-01-01
An approach to the application of high Tc ceramic superconductors to practical circuit elements was developed and demonstrated. This method, known as the rigid-conductor process (RCP), involves the combination of a pre-formed, sintered, and tested superconductor material with an appropriate, rigid substrate via an epoxy adhesive which also serves to encapsulate the element from the ambient environment. Emphasis was on the practical means to achieve functional, reliable, and reproducible components. Although all of the work described in this report involved a YBa2Cu3Osub(7-x) high Tc superconductor material, the techniques developed and conclusions reached are equally applicable to other high Tc materials.
Recent progress of erbium-doped fiber amplifiers and their components
NASA Astrophysics Data System (ADS)
Fukushima, Masaru; Miura, Jutaro
2007-09-01
The Erbium-doped fiber amplifiers (EDFA) are widely available in a today's commercial market, and are deployed in various optical transmission applications from terrestrial system to undersea system. Broad gain spectrum over 9 THz enabled huge growth of bandwidth usage in 1550nm region aimed at broadband Internet, and its broad gain characteristics triggered bandwidth competition on dense wavelength division multiplex (DWDM) network these ten years. At first, we briefly review the evolutional history of EDFA with previous achievements. And we will explain the primary and important key devices which compose EDFA. We will discuss design parameters, and recent trend and achievements of the devices, which cover Erbium-doped fibers (EDF), 980-nm laser diodes (LD), and gain flattening filters (GFFs). The chip structure of 980-nm LD is explained to achieve high power and to realize high reliability. These key devices enabled EDFA to prevail in commercial area. After the discussion of key components, we will introduce recent achievements of gain controlled EDFAs which are applied in conjunction with Re-configurable Optical Add/Drop Multiplexer (ROADM). We will report the transient gain dynamics of the cascaded EDFAs with a recirculating loop experiment.
Carter, Amanda G; Creedy, Debra K; Sidebotham, Mary
2017-11-01
develop and test a tool designed for use by academics to evaluate pre-registration midwifery students' critical thinking skills in reflective writing. a descriptive cohort design was used. a random sample (n = 100) of archived student reflective writings based on a clinical event or experience during 2014 and 2015. a staged model for tool development was used to develop a fifteen item scale involving item generation; mapping of draft items to critical thinking concepts and expert review to test content validity; inter-rater reliability testing; pilot testing of the tool on 100 reflective writings; and psychometric testing. Item scores were analysed for mean, range and standard deviation. Internal reliability, content and construct validity were assessed. expert review of the tool revealed a high content validity index score of 0.98. Using two independent raters to establish inter-rater reliability, good absolute agreement of 72% was achieved with a Kappa coefficient K = 0.43 (p<0.0001). Construct validity via exploratory factor analysis revealed three factors: analyses context, reasoned inquiry, and self-evaluation. The mean total score for the tool was 50.48 (SD = 12.86). Total and subscale scores correlated significantly. The scale achieved good internal reliability with a Cronbach's alpha coefficient of .93. this study establishedthe reliability and validity of the CACTiM (reflection) for use by academics to evaluate midwifery students' critical thinking in reflective writing. Validation with large diverse samples is warranted. reflective practice is a key learning and teaching strategy in undergraduate Bachelor of Midwifery programmes and essential for safe, competent practice. There is the potential to enhance critical thinking development by assessingreflective writing with the CACTiM (reflection) tool to provide formative and summative feedback to students and inform teaching strategies. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Yang, Yuan; Quan, Nannan; Bu, Jingjing; Li, Xueping; Yu, Ningmei
2016-09-26
High order modulation and demodulation technology can solve the frequency requirement between the wireless energy transmission and data communication. In order to achieve reliable wireless data communication based on high order modulation technology for visual prosthesis, this work proposed a Reed-Solomon (RS) error correcting code (ECC) circuit on the basis of differential amplitude and phase shift keying (DAPSK) soft demodulation. Firstly, recognizing the weakness of the traditional DAPSK soft demodulation algorithm based on division that is complex for hardware implementation, an improved phase soft demodulation algorithm for visual prosthesis to reduce the hardware complexity is put forward. Based on this new algorithm, an improved RS soft decoding method is hence proposed. In this new decoding method, the combination of Chase algorithm and hard decoding algorithms is used to achieve soft decoding. In order to meet the requirements of implantable visual prosthesis, the method to calculate reliability of symbol-level based on multiplication of bit reliability is derived, which reduces the testing vectors number of Chase algorithm. The proposed algorithms are verified by MATLAB simulation and FPGA experimental results. During MATLAB simulation, the biological channel attenuation property model is added into the ECC circuit. The data rate is 8 Mbps in the MATLAB simulation and FPGA experiments. MATLAB simulation results show that the improved phase soft demodulation algorithm proposed in this paper saves hardware resources without losing bit error rate (BER) performance. Compared with the traditional demodulation circuit, the coding gain of the ECC circuit has been improved by about 3 dB under the same BER of [Formula: see text]. The FPGA experimental results show that under the condition of data demodulation error with wireless coils 3 cm away, the system can correct it. The greater the distance, the higher the BER. Then we use a bit error rate analyzer to measure BER of the demodulation circuit and the RS ECC circuit with different distance of two coils. And the experimental results show that the RS ECC circuit has about an order of magnitude lower BER than the demodulation circuit when under the same coils distance. Therefore, the RS ECC circuit has more higher reliability of the communication in the system. The improved phase soft demodulation algorithm and soft decoding algorithm proposed in this paper enables data communication that is more reliable than other demodulation system, which also provide a significant reference for further study to the visual prosthesis system.
Daniels, Vijay J; Bordage, Georges; Gierl, Mark J; Yudkowsky, Rachel
2014-10-01
Objective structured clinical examinations (OSCEs) are used worldwide for summative examinations but often lack acceptable reliability. Research has shown that reliability of scores increases if OSCE checklists for medical students include only clinically relevant items. Also, checklists are often missing evidence-based items that high-achieving learners are more likely to use. The purpose of this study was to determine if limiting checklist items to clinically discriminating items and/or adding missing evidence-based items improved score reliability in an Internal Medicine residency OSCE. Six internists reviewed the traditional checklists of four OSCE stations classifying items as clinically discriminating or non-discriminating. Two independent reviewers augmented checklists with missing evidence-based items. We used generalizability theory to calculate overall reliability of faculty observer checklist scores from 45 first and second-year residents and predict how many 10-item stations would be required to reach a Phi coefficient of 0.8. Removing clinically non-discriminating items from the traditional checklist did not affect the number of stations (15) required to reach a Phi of 0.8 with 10 items. Focusing the checklist on only evidence-based clinically discriminating items increased test score reliability, needing 11 stations instead of 15 to reach 0.8; adding missing evidence-based clinically discriminating items to the traditional checklist modestly improved reliability (needing 14 instead of 15 stations). Checklists composed of evidence-based clinically discriminating items improved the reliability of checklist scores and reduced the number of stations needed for acceptable reliability. Educators should give preference to evidence-based items over non-evidence-based items when developing OSCE checklists.
Tian, Liangliang; He, Gege; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Yang, Cong; Chen, Yanling; Li, Lu
2018-02-16
Inspired by kinetics, the design of hollow hierarchical electrocatalysts through large-scale integration of building blocks is recognized as an effective approach to the achievement of superior electrocatalytic performance. In this work, a hollow, hierarchical Co 3 O 4 architecture (Co 3 O 4 HHA) was constructed using a coordinated etching and precipitation (CEP) method followed by calcination. The resulting Co 3 O 4 HHA electrode exhibited excellent electrocatalytic activity in terms of high sensitivity (839.3 μA mM -1 cm -2 ) and reliable stability in glucose detection. The high sensitivity could be attributed to the large specific surface area (SSA), ample unimpeded penetration diffusion paths and high electron transfer rate originating from the unique two-dimensional (2D) sheet-like character and hollow porous architecture. The hollow hierarchical structure also affords sufficient interspace for accommodation of volume change and structural strain, resulting in enhanced stability. The results indicate that Co 3 O 4 HHA could have potential for application in the design of non-enzymatic glucose sensors, and that the construction of hollow hierarchical architecture provides an efficient way to design highly active, stable electrocatalysts.
NASA Astrophysics Data System (ADS)
Tian, Liangliang; He, Gege; Cai, Yanhua; Wu, Shenping; Su, Yongyao; Yan, Hengqing; Yang, Cong; Chen, Yanling; Li, Lu
2018-02-01
Inspired by kinetics, the design of hollow hierarchical electrocatalysts through large-scale integration of building blocks is recognized as an effective approach to the achievement of superior electrocatalytic performance. In this work, a hollow, hierarchical Co3O4 architecture (Co3O4 HHA) was constructed using a coordinated etching and precipitation (CEP) method followed by calcination. The resulting Co3O4 HHA electrode exhibited excellent electrocatalytic activity in terms of high sensitivity (839.3 μA mM-1 cm-2) and reliable stability in glucose detection. The high sensitivity could be attributed to the large specific surface area (SSA), ample unimpeded penetration diffusion paths and high electron transfer rate originating from the unique two-dimensional (2D) sheet-like character and hollow porous architecture. The hollow hierarchical structure also affords sufficient interspace for accommodation of volume change and structural strain, resulting in enhanced stability. The results indicate that Co3O4 HHA could have potential for application in the design of non-enzymatic glucose sensors, and that the construction of hollow hierarchical architecture provides an efficient way to design highly active, stable electrocatalysts.
Efficient Unsteady Flow Visualization with High-Order Access Dependencies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jiang; Guo, Hanqi; Yuan, Xiaoru
We present a novel high-order access dependencies based model for efficient pathline computation in unsteady flow visualization. By taking longer access sequences into account to model more sophisticated data access patterns in particle tracing, our method greatly improves the accuracy and reliability in data access prediction. In our work, high-order access dependencies are calculated by tracing uniformly-seeded pathlines in both forward and backward directions in a preprocessing stage. The effectiveness of our proposed approach is demonstrated through a parallel particle tracing framework with high-order data prefetching. Results show that our method achieves higher data locality and hence improves the efficiencymore » of pathline computation.« less
Liberty, Kathleen A; Pattemore, Philip; Reid, James; Tarren-Sweeney, Michael
2010-12-01
Concerns about the achievement of children with asthma and respiratory conditions are especially important in New Zealand, which has one of the world's highest rates of childhood asthma. The present study evaluated whether entering school with asthma was associated with low achievement after the first year. A child cohort was recruited to a prospective study at time of first enrollment into randomly selected schools in Christchurch. Parent interviews covered demographics and respiratory status. Physician reports were sought for children with asthma, and all respiratory information was clinically reviewed. The children's achievement in reading and math was individually assessed at school entry and reassessed after 12 months. Schools reported absences. Intelligence subtests were administered. Two hundred ninety-eight children were recruited, including 55 (18.5%) with current asthma. At 1-year follow-up, retention was 93.7%. Children who entered school with asthma were more likely to be ≥ 6 months behind other participants in reading words (P = .023) and books (P = .026), but not in math (P = .167) at the end of the first year of school. Achievement was not related to asthma severity. Entering school with asthma reliably predicted low reading achievement independent of other known covariates of low achievement (high absenteeism, minority status, male gender, single-parent family, poor academic skills at school entry, and low socioeconomic status). Entering school with asthma was a significant predictor of low achievement in reading at 12-month follow-up, independent of asthma severity, high absenteeism, or other covariates of low achievement.
NASA Technical Reports Server (NTRS)
Lalli, Vincent R. (Editor); Malec, Henry A. (Editor); Dillard, Richard B.; Wong, Kam L.; Barber, Frank J.; Barina, Frank J.
1992-01-01
Discussed here is failure physics, the study of how products, hardware, software, and systems fail and what can be done about it. The intent is to impart useful information, to extend the limits of production capability, and to assist in achieving low cost reliable products. A review of reliability for the years 1940 to 2000 is given. Next, a review of mathematics is given as well as a description of what elements contribute to product failures. Basic reliability theory and the disciplines that allow us to control and eliminate failures are elucidated.
Wu, Y Z; Wang, W J; Feng, N P; Chen, B; Li, G C; Liu, J W; Liu, H L; Yang, Y Y
2016-07-06
To evaluate the validity, reliability, and acceptability of the brief version of the self-management knowledge, attitude, and behavior (KAB) assessment scale for diabetes patients. Diabetes patients who were managed at the Xinkaipu Community Health Service Center of Tianxin in Changsha, Hunan Province were selected for survey by cluster sampling. A total of 350 diabetes patients were surveyed using the brief scale to collect data on knowledge, attitudes, and behaviors of self-management. Content validity was evaluated by Pearson correlation coefficient between the brief scale and subscales of knowledge, attitude, and behavior. Structure validity was evaluated by factor analysis, and discrimination validity was evaluated by an independent sample t-test between the high-score and low-score groups. Reliability was tested by internal consistency reliability and split-half reliability. The evaluation indexes of internal consistency reliability were Cronbach's α coefficients, θ coefficient, and Ω coefficient. Acceptability was evaluated by valid response rate and completion time of the brief scale. A total of 346(98.9%) valid questionnaires were returned, with average survey time of (11.43±3.4) minutes. Average score of the brief scale was 78.85 ± 11.22; scores of the knowledge, attitude, and behavior subscales were 16.45 ± 4.42, 21.33 ± 2.03, and 41.07 ± 8.34, respectively. Pearson correlation coefficients between the brief scale and the knowledge, attitude, and behavior subscales were 0.92, 0.42, and 0.60, respectively; P-values were all less than 0.01, indicating that the face validity and content validity of the brief scale were achieved to a good level. The common factor cumulative variance contribution rate of the brief scale and three subscales was from 53.66% to 61.75%, which achieved more than 50% of the approved standard. There were 11 common factors; 41 of the total 42 items had factor loadings above 0.40 in their relevant common factor, indicating that the brief scale and three subscales had good construct validity. Patients were divided into a high-score group and a low-score group, then scores of the brief scale and three subscales were compared between the groups using a t-test. The results were all significant, indicating that the brief scale and three subscales had good discriminate validity. Mean scores of the brief scale and three subscales of the high-score group were 91.55±6.81, 19.51±2.17, 22.74±1.88, and 49.30±6.20, respectively; these were higher than the low-score group (65.89±5.79, 12.29±4.76, 20.22±1.88, and 33.39±6.17, respectively) with t-values 27.76, 13.31, 9.20, and 17.56 (P-values were less than 0.001). The Cronbach's α coefficient, θ coefficient, Ω coefficient, and split-half reliability of the brief scale were 0.83, 0.87, 0.96, and 0.84, respectively. These values for the three subscales were all above 0.70, except for the θ coefficient of the attitude subscale with 0.64, indicating that the brief scale and three subscales had acceptable internal consistency reliability. The brief version of the diabetes self-management knowledge, attitude, and behavior assessment scale showed good acceptability, validity, and reliability, to responsibly evaluate self-management KAB among patients with diabetes.
Frequently Asked Questions about Rotavirus
... Scientific Achievement John P. Utz Leadership Award Dr. Charles Mérieux Award for Achievement in Vaccinology and Immunology ... There's no reliable way to predict how rotavirus will affect your child. New and expecting parents should ...
2013-08-01
thermoset system designed to achieve good wetting , high-strength and low-creep adhesion. Many commercially-available adhesives were sourced and...Bragg grating: 1. Removal of the fibre coating. 2. Photosensitization of the fibre. 3. Exposure of the grating to UV laser light. 4. Annealing and...molecular hydrogen loading (H2 loading) in a heated pressure vessel . Photosensitisation results in a stronger refractive index contrast for a given
Charting the Course for a New Air Force Inspection System
2013-01-01
are down the hall from 3 All normative or prescriptive statements in this section reflect statements we heard from Air Force personnel. reducing the...in multiple forms. The responses we heard in the field tell us that the Air Force will achieve a better reception for MICT if its leadership first...primarily from the theory of High Reliability Organizations (HROs) pioneered by Karlene H. Roberts,9 whose work owed a great deal to the same body of
Song, Jiangxin; Lin, Jintian; Tang, Jialei; Liao, Yang; He, Fei; Wang, Zhaohui; Qiao, Lingling; Sugioka, Koji; Cheng, Ya
2014-06-16
We report on fabrication of a microtoroid resonator of a high-quality factor (i.e., Q-factor of ~3.24 × 10(6) measured under the critical coupling condition) integrated in a microfluidic channel using femtosecond laser three-dimensional (3D) micromachining. Coupling of light into and out of the microresonator has been realized with a fiber taper that is reliably assembled with the microtoroid. The assembly of the fiber to the microtoroid is achieved by welding the fiber taper onto the sidewall of the microtoroid using CO2 laser irradiation. The integrated microresonator maintains a high Q-factor of 3.21 × 10(5) as measured in air, which should still be sufficient for many sensing applications. We test the functionality of the integrated optofluidic sensor by performing bulk refractive index sensing of purified water doped with tiny amount of salt. It is shown that a detection limit of ~1.2 × 10(-4) refractive index unit can be achieved. Our result showcases the capability of integration of high-Q microresonators with complex microfluidic systems using femtosecond laser 3D micromachining.
Methodology for Physics and Engineering of Reliable Products
NASA Technical Reports Server (NTRS)
Cornford, Steven L.; Gibbel, Mark
1996-01-01
Physics of failure approaches have gained wide spread acceptance within the electronic reliability community. These methodologies involve identifying root cause failure mechanisms, developing associated models, and utilizing these models to inprove time to market, lower development and build costs and higher reliability. The methodology outlined herein sets forth a process, based on integration of both physics and engineering principles, for achieving the same goals.
NASA Astrophysics Data System (ADS)
Bulmer, John J.
Ultraviolet (UV) radiation detectors are being heavily researched for applications in non-line-of-sight (NLOS) communication systems, flame monitoring, biological detection, and astronomical studies. These applications are currently being met by the use of Si-based photomultiplier tubes (PMTs), which are bulky, fragile, expensive and require the use of external filters to achieve true visible-blind and solar-blind operation. GaN and AlxGa1-xN avalanche photodiodes have been of great interest as a replacement for PMT technology. III-Nitride materials are radiation hard and have a wide, tunable bandgap that allows devices to operate in both visible and solar-blind regimes without the use of external filters. The high price and relative unavailability of bulk substrates demands heteroepitaxy of III-Nitride films on lattice-mismatched substrates, which leads to large dark current and premature breakdown in GaN and AlGaN avalanche photodiodes. While significant advances have been made towards the development of III-Nitride UV photodetectors using a variety of device designs, GaN-based avalanche photodiodes typically demonstrate poor device performance, low yield, and breakdown that results in permanent device damage. To address these challenges, a novel implantation technique was used to achieve edge termination and electric field redistribution at the contact edges in GaN and AlGaN p-i-n photodiode structures to enhance reliability. This process was successful at significantly reducing the levels of dark current over two orders of magnitude and resulted in improved device reliability. Further improvement in reliability of III-Nitride devices was also proposed and explored by a technique for isolation of electrically conductive structural defects. The large number of dislocations induced by the lattice and thermal mismatch with the substrate are known to be leakage current pathways and non-radiative recombination centers in III-Nitride films. This process selectively isolates conductive pathways in III-Nitrides using an electrochemical etch and novel foam passivation technique. Establishing improved photodiode performance and device reliability, 4x4 and 8x8 arrays of GaN p-i-n photodiodes were demonstrated and integrated with external circuitry to generate image patterns using 360nm illumination. This work represents significant progress towards the realization of reliable III-Nitride UV detectors arrays and future directions are proposed in order to demonstrate large-scale arrays for high-resolution ultraviolet imaging.
Spectral imaging spreads into new industrial and on-field applications
NASA Astrophysics Data System (ADS)
Bouyé, Clémentine; Robin, Thierry; d'Humières, Benoît
2018-02-01
Numerous recent innovative developments have led to a high reduction of hyperspectral and multispectral cameras cost and size. The achieved products - compact, reliable, low-cot, easy-to-use - meet end-user requirements in major fields: agriculture, food and beverages, pharmaceutics, machine vision, health. The booming of this technology in industrial and on-field applications is getting closer. Indeed, the Spectral Imaging market is at a turning point. A high growth rate of 20% is expected in the next 5 years. The number of cameras sold will increase from 3 600 in 2017 to more than 9 000 in 2022.
GEODE An electrical energy supply with high availability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mertz, J.L.; Gerard, M.J.; Girard, J.
1983-10-01
Project GEODE describes an electrical energy supply characterized by its very high availability. It is to be used in the PTT (French Telephone Company) telephone exchanges and is targeted for an unavailability of better than 10/sup -6/. In order to achieve this performance Merlin Gerin has adopted: a double bus bar architecture, remote controlled electrical equipment, a motor-generator set specifically designed for this project, and computer assisted surveillance. The authors present the overall reliability calculations for this project along with that for energy sources. The E.d.F (French Utility Company) network and the Motor-Generators.
A miniature on-chip multi-functional ECG signal processor with 30 µW ultra-low power consumption.
Liu, Xin; Zheng, Yuan Jin; Phyu, Myint Wai; Zhao, Bin; Je, Minkyu; Yuan, Xiao Jun
2010-01-01
In this paper, a miniature low-power Electrocardiogram (ECG) signal processing application specific integrated circuit (ASIC) chip is proposed. This chip provides multiple critical functions for ECG analysis using a systematic wavelet transform algorithm and a novel SRAM-based ASIC architecture, while achieves low cost and high performance. Using 0.18 µm CMOS technology and 1 V power supply, this ASIC chip consumes only 29 µW and occupies an area of 3 mm(2). This on-chip ECG processor is highly suitable for reliable real-time cardiac status monitoring applications.
Development of 70 MW class superconducting generator with quick-response excitation
NASA Astrophysics Data System (ADS)
Miyaike, Kiyoshi; Kitajima, Toshio; Ito, Tetsuo
2002-03-01
The development of a superconducting generator had been carried out for 12 years under the first stage of a Super GM project. The 70 MW class model machine with quick response excitation was manufactured and evaluated in the project. This type of superconducting generator improves power system stability against rapid load fluctuations at the power system faults. This model machine achieved all development targets including high stability during rapid excitation control. It was also connected to the actual 77 kV electrical power grid as a synchronous condenser and proved advantages and high-operation reliability of the superconducting generator.
A PC program to optimize system configuration for desired reliability at minimum cost
NASA Technical Reports Server (NTRS)
Hills, Steven W.; Siahpush, Ali S.
1994-01-01
High reliability is desired in all engineered systems. One way to improve system reliability is to use redundant components. When redundant components are used, the problem becomes one of allocating them to achieve the best reliability without exceeding other design constraints such as cost, weight, or volume. Systems with few components can be optimized by simply examining every possible combination but the number of combinations for most systems is prohibitive. A computerized iteration of the process is possible but anything short of a super computer requires too much time to be practical. Many researchers have derived mathematical formulations for calculating the optimum configuration directly. However, most of the derivations are based on continuous functions whereas the real system is composed of discrete entities. Therefore, these techniques are approximations of the true optimum solution. This paper describes a computer program that will determine the optimum configuration of a system of multiple redundancy of both standard and optional components. The algorithm is a pair-wise comparative progression technique which can derive the true optimum by calculating only a small fraction of the total number of combinations. A designer can quickly analyze a system with this program on a personal computer.
Preliminary design of the redundant software experiment
NASA Technical Reports Server (NTRS)
Campbell, Roy; Deimel, Lionel; Eckhardt, Dave, Jr.; Kelly, John; Knight, John; Lauterbach, Linda; Lee, Larry; Mcallister, Dave; Mchugh, John
1985-01-01
The goal of the present experiment is to characterize the fault distributions of highly reliable software replicates, constructed using techniques and environments which are similar to those used in comtemporary industrial software facilities. The fault distributions and their effect on the reliability of fault tolerant configurations of the software will be determined through extensive life testing of the replicates against carefully constructed randomly generated test data. Each detected error will be carefully analyzed to provide insight in to their nature and cause. A direct objective is to develop techniques for reducing the intensity of coincident errors, thus increasing the reliability gain which can be achieved with fault tolerance. Data on the reliability gains realized, and the cost of the fault tolerant configurations can be used to design a companion experiment to determine the cost effectiveness of the fault tolerant strategy. Finally, the data and analysis produced by this experiment will be valuable to the software engineering community as a whole because it will provide a useful insight into the nature and cause of hard to find, subtle faults which escape standard software engineering validation techniques and thus persist far into the software life cycle.
Confirmatory Factor Analysis of Achieving the Beginning Teacher Standards Inventory
ERIC Educational Resources Information Center
Chen, Weiyun
2009-01-01
The purpose of this study was to examine the factorial validity and reliability of the "Achieving the NASPE Standards Inventory (ANSI)" that assesses pre-service physical education teachers' perceptions of achieving the National Association for Sport and Physical Education (NASPE) beginning teacher standards (2003). Four hundred fifty-two…
Chen, Yu-Cheng; Coble, Joseph B; Deziel, Nicole C; Ji, Bu-Tian; Xue, Shouzheng; Lu, Wei; Stewart, Patricia A; Friesen, Melissa C
2014-11-01
The reliability and validity of six experts' exposure ratings were evaluated for 64 nickel-exposed and 72 chromium-exposed workers from six Shanghai electroplating plants based on airborne and urinary nickel and chromium measurements. Three industrial hygienists and three occupational physicians independently ranked the exposure intensity of each metal on an ordinal scale (1-4) for each worker's job in two rounds: the first round was based on responses to an occupational history questionnaire and the second round also included responses to an electroplating industry-specific questionnaire. The Spearman correlation (r(s)) was used to compare each rating's validity to its corresponding subject-specific arithmetic mean of four airborne or four urinary measurements. Reliability was moderately high (weighted kappa range=0.60-0.64). Validity was poor to moderate (r(s)=-0.37-0.46) for both airborne and urinary concentrations of both metals. For airborne nickel concentrations, validity differed by plant. For dichotomized metrics, sensitivity and specificity were higher based on urinary measurements (47-78%) than airborne measurements (16-50%). Few patterns were observed by metal, assessment round, or expert type. These results suggest that, for electroplating exposures, experts can achieve moderately high agreement and (reasonably) distinguish between low and high exposures when reviewing responses to in-depth questionnaires used in population-based case-control studies.
Chen, Yu-Cheng; Coble, Joseph B; Deziel, Nicole C.; Ji, Bu-Tian; Xue, Shouzheng; Lu, Wei; Stewart, Patricia A; Friesen, Melissa C
2014-01-01
The reliability and validity of six experts’ exposure ratings were evaluated for 64 nickel-exposed and 72 chromium-exposed workers from six Shanghai electroplating plants based on airborne and urinary nickel and chromium measurements. Three industrial hygienists and three occupational physicians independently ranked the exposure intensity of each metal on an ordinal scale (1–4) for each worker's job in two rounds: the first round was based on responses to an occupational history questionnaire and the second round also included responses to an electroplating industry-specific questionnaire. Spearman correlation (rs) was used to compare each rating's validity to its corresponding subject-specific arithmetic mean of four airborne or four urinary measurements. Reliability was moderately-high (weighted kappa range=0.60–0.64). Validity was poor to moderate (rs= -0.37–0.46) for both airborne and urinary concentrations of both metals. For airborne nickel concentrations, validity differed by plant. For dichotomized metrics, sensitivity and specificity were higher based on urinary measurements (47–78%) than airborne measurements (16–50%). Few patterns were observed by metal, assessment round, or expert type. These results suggest that, for electroplating exposures, experts can achieve moderately-high agreement and (reasonably) distinguish between low and high exposures when reviewing responses to in-depth questionnaires used in population-based case-control studies. PMID:24736099
Kenfaui, Driss; Sibeud, Pierre-Frédéric; Gomina, Moussa; Louradour, Eric; Chaud, Xavier; Noudem, Jacques G
2015-08-06
In the quest of YBa2Cu3O(7-δ) (Y123) bulk superconductors providing strong magnetic fields without failure, it is of paramount importance to achieve high thermal stabilities to safeguard the magnetic energy inside them during the trapping-field process, and sufficient mechanical reliability to withstand the stresses derived from the Lorenz force. Herein, we experimentally demonstrate a temperature rise induced by dissipative flux motion inside an Y123 thin-wall superconductor, and a significant thermal exchange in a composite bulk Y123 cryomagnet realized by embedding this superconductor with high thermal-conductivity metal network. It resulted in stimulating the maximum trapped field Bm, which reached 6.46 T on 15.9 mm-diameter single disk superconductor after magnetization by field cooling to 17 K under 7 T, leading to an improvement of 18% compared to the thin-wall superconductor. The composite cryomagnet particularly revealed the potential to trap stronger fields if larger magnetic activation is available. By virtue of the pore-free and crack-free microstructure of this cryomagnet, its strength σR was estimated to be 363 MPa, the largest one obtained so far for Y123 bulk superconductors, thus suggesting a striking mechanical reliability that seems to be sufficient to sustain stresses derived from trapped fields stronger than any values hitherto reported.
Investigation of veritcal graded channel doping in nanoscale fully-depleted SOI-MOSFET
NASA Astrophysics Data System (ADS)
Ramezani, Zeinab; Orouji, Ali A.
2016-10-01
For achieving reliable transistor, we investigate an amended channel doping (ACD) engineering which improves the electrical and thermal performances of fully-depleted silicon-on-insulator (SOI) MOSFET. We have called the proposed structure with the amended channel doping engineering as ACD-SOI structure and compared it with a conventional fully-depleted SOI MOSFET (C-SOI) with uniform doping distribution using 2-D ATLAS simulator. The amended channel doping is a vertical graded doping that is distributed from the surface of structure with high doping density to the bottom of channel, near the buried oxide, with low doping density. Short channel effects (SCEs) and leakage current suppress due to high barrier height near the source region and electric field modification in the ACD-SOI in comparison with the C-SOI structure. Furthermore, by lower electric field and electron temperature near the drain region that is the place of hot carrier generation, we except the improvement of reliability and gate induced drain lowering (GIDL) in the proposed structure. Undesirable Self heating effect (SHE) that become a critical challenge for SOI MOSFETs is alleviated in the ACD-SOI structure because of utilizing low doping density near the buried oxide. Thus, refer to accessible results, the ACD-SOI structure with graded distribution in vertical direction is a reliable device especially in low power and high temperature applications.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, Nam-Gyu; Grätzel, Michael; Miyasaka, Tsutomu
Solar cells employing a halide perovskite with an organic cation now show power conversion efficiency of up to 22%. But, these cells are facing issues towards commercialization, such as the need to achieve long-term stability and the development of a manufacturing method for the reproducible fabrication of high-performance devices. We propose a strategy to obtain stable and commercially viable perovskite solar cells. A reproducible manufacturing method is suggested, as well as routes to manage grain boundaries and interfacial charge transport. Electroluminescence is regarded as a metric to gauge theoretical efficiency. We highlight how optimizing the design of device architectures ismore » important not only for achieving high efficiency but also for hysteresis-free and stable performance. Here, we argue that reliable device characterization is needed to ensure the advance of this technology towards practical applications. We believe that perovskite-based devices can be competitive with silicon solar modules, and discuss issues related to the safe management of toxic material.« less
A novel Laser Ion Mobility Spectrometer
NASA Astrophysics Data System (ADS)
Göbel, J.; Kessler, M.; Langmeier, A.
2009-05-01
IMS is a well know technology within the range of security based applications. Its main advantages lie in the simplicity of measurement, along with a fast and sensitive detection method. Contemporary technology often fails due to interference substances, in conjunction with saturation effects and a low dynamic detection range. High throughput facilities, such as airports, require the analysis of many samples at low detection limits within a very short timeframe. High detection reliability is a requirement for safe and secure operation. In our present work we developed a laser based ion-mobility-sensor which shows several advantages over known IMS sensor technology. The goal of our research was to increase the sensitivity compared to the range of 63Ni based instruments. This was achieved with an optimised geometric drift tube design and a pulsed UV laser system at an efficient intensity. In this intensity range multi-photon ionisation is possible, which leads to higher selectivity in the ion-formation process itself. After high speed capturing of detection samples, a custom designed pattern recognition software toolbox provides reliable auto-detection capability with a learning algorithm and a graphical user interface.
Fabrication of capsule assemblies, phase 3
NASA Technical Reports Server (NTRS)
Keeton, A. R.; Stemann, L. G.
1973-01-01
Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.
2009-10-01
phase and factors which may cause accelerated growth rates is key to achieving a reliable and robust bearing design . The end goal is to identify...key to achieving a reliable and robust bearing design . The end goal is to identify control parameters for optimizing bearing materials for improved...25.0 nm and were each fabricated from same material heats respectively to a custom design print to ABEC 5 quality and had split inner rings. Each had
Towards Autonomous Inspection of Space Systems Using Mobile Robotic Sensor Platforms
NASA Technical Reports Server (NTRS)
Wong, Edmond; Saad, Ashraf; Litt, Jonathan S.
2007-01-01
The space transportation systems required to support NASA's Exploration Initiative will demand a high degree of reliability to ensure mission success. This reliability can be realized through autonomous fault/damage detection and repair capabilities. It is crucial that such capabilities are incorporated into these systems since it will be impractical to rely upon Extra-Vehicular Activity (EVA), visual inspection or tele-operation due to the costly, labor-intensive and time-consuming nature of these methods. One approach to achieving this capability is through the use of an autonomous inspection system comprised of miniature mobile sensor platforms that will cooperatively perform high confidence inspection of space vehicles and habitats. This paper will discuss the efforts to develop a small scale demonstration test-bed to investigate the feasibility of using autonomous mobile sensor platforms to perform inspection operations. Progress will be discussed in technology areas including: the hardware implementation and demonstration of robotic sensor platforms, the implementation of a hardware test-bed facility, and the investigation of collaborative control algorithms.
Muthukumarasamy, S; Osmani, Z; Sharpe, A; England, R J A
2012-02-01
This study aimed to assess the quality of information available on the World Wide Web for patients undergoing thyroidectomy. The first 50 web-links generated by internet searches using the five most popular search engines and the key word 'thyroidectomy' were evaluated using the Lida website validation instrument (assessing accessibility, usability and reliability) and the Flesch Reading Ease Score. We evaluated 103 of a possible 250 websites. Mean scores (ranges) were: Lida accessibility, 48/63 (27-59); Lida usability, 36/54 (21-50); Lida reliability, 21/51 (4-38); and Flesch Reading Ease, 43.9 (2.6-77.6). The quality of internet health information regarding thyroidectomy is variable. High ranking and popularity are not good indicators of website quality. Overall, none of the websites assessed achieved high Lida scores. In order to prevent the dissemination of inaccurate or commercially motivated information, we recommend independent labelling of medical information available on the World Wide Web.
Toward lean satellites reliability improvement using HORYU-IV project as case study
NASA Astrophysics Data System (ADS)
Faure, Pauline; Tanaka, Atomu; Cho, Mengu
2017-04-01
Lean satellite programs are programs in which the satellite development philosophy is driven by fast delivery and low cost. Though this concept offers the possibility to develop and fly risky missions without jeopardizing a space program, most of these satellites suffer infant mortality and fail to achieve their mission minimum success. Lean satellites with high infant mortality rate indicate that testing prior to launch is insufficient. In this study, the authors monitored failures occurring during the development of the lean satellite HORYU-IV to identify the evolution of the cumulative number of failures against cumulative testing time. Moreover, the sub-systems driving the failures depending on the different development phases were identified. The results showed that half to 2/3 of the failures are discovered during the early stage of testing. Moreover, when the mean time before failure was calculated, it appeared that for any development phase considered, a new failure appears on average every 20 h of testing. Simulations were also performed and it showed that for an initial testing time of 50 h, reliability after 1 month launch can be improved by nearly 6 times as compared to an initial testing time of 20 h. Through this work, the authors aim at providing a qualitative reference for lean satellites developers to better help them manage resources to develop lean satellites following a fast delivery and low cost philosophy while ensuring sufficient reliability to achieve mission minimum success.
Reliability of anthropometric measurements in European preschool children: the ToyBox-study.
De Miguel-Etayo, P; Mesana, M I; Cardon, G; De Bourdeaudhuij, I; Góźdź, M; Socha, P; Lateva, M; Iotova, V; Koletzko, B V; Duvinage, K; Androutsos, O; Manios, Y; Moreno, L A
2014-08-01
The ToyBox-study aims to develop and test an innovative and evidence-based obesity prevention programme for preschoolers in six European countries: Belgium, Bulgaria, Germany, Greece, Poland and Spain. In multicentre studies, anthropometric measurements using standardized procedures that minimize errors in the data collection are essential to maximize reliability of measurements. The aim of this paper is to describe the standardization process and reliability (intra- and inter-observer) of height, weight and waist circumference (WC) measurements in preschoolers. All technical procedures and devices were standardized and centralized training was given to the fieldworkers. At least seven children per country participated in the intra- and inter-observer reliability testing. Intra-observer technical error ranged from 0.00 to 0.03 kg for weight and from 0.07 to 0.20 cm for height, with the overall reliability being above 99%. A second training was organized for WC due to low reliability observed in the first training. Intra-observer technical error for WC ranged from 0.12 to 0.71 cm during the first training and from 0.05 to 1.11 cm during the second training, and reliability above 92% was achieved. Epidemiological surveys need standardized procedures and training of researchers to reduce measurement error. In the ToyBox-study, very good intra- and-inter-observer agreement was achieved for all anthropometric measurements performed. © 2014 World Obesity.
Silicon Detector System for High Rate EXAFS Applications.
Pullia, A; Kraner, H W; Siddons, D P; Furenlid, L R; Bertuccio, G
1995-08-01
A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at -35 °C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at -35 °C. At room temperature (25 °C) an average energy resolution of 380 eV FWHM is achieved and a resolution of 350 eV FWHM (41 rms electrons) is the best performance. A simple cooling system constituted of Peltier cells is sufficient to reduce the reverse currents of the pads and their related shot noise contribution, in order to achieve resolutions better than 300 eV FWHM which is adequate for the EXAFS applications.
Silicon Detector System for High Rate EXAFS Applications
Pullia, A.; Kraner, H. W.; Siddons, D. P.; Furenlid, L. R.; Bertuccio, G.
2015-01-01
A multichannel silicon pad detector for EXAFS (Extended X-ray Absorption Fine Structure) applications has been designed and built. The X-ray spectroscopic measurements demonstrate that an adequate energy resolution of 230 eV FWHM (corresponding to 27 rms electrons in silicon) can be achieved reliably at −35 °C. A resolution of 190 eV FWHM (corresponding to 22 rms electrons) has been obtained from individual pads at −35 °C. At room temperature (25 °C) an average energy resolution of 380 eV FWHM is achieved and a resolution of 350 eV FWHM (41 rms electrons) is the best performance. A simple cooling system constituted of Peltier cells is sufficient to reduce the reverse currents of the pads and their related shot noise contribution, in order to achieve resolutions better than 300 eV FWHM which is adequate for the EXAFS applications. PMID:26538683
NASA Astrophysics Data System (ADS)
Filis, Avishai; Pundak, Nachman; Barak, Moshe; Porat, Ze'ev; Jaeger, Mordechai
2011-06-01
The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and decreased integrated system Life Cycle (ILS) cost. In order to meet this need RICOR has developed a new rotary Stirling cryocooler, model K508N, intended to double the K508's operating MTTF achieving 20,000 operating MTTF hours. The K508N employs RICOR's latest mechanical design technologies such as optimized bearings and greases, bearings preloading, advanced seals, laser welded cold finger and robust design structure with increased natural frequency compared to the K508 model. The cooler enhanced MTTF was demonstrated by a Validation and Verification (V&V) plan comprising analytical means and a comparative accelerated life test between the standard K508 and the K508N models. Particularly, point estimate and confidence interval for the MTTF improvement factor where calculated periodically during and after the test. The (V&V) effort revealed that the K508N meets its MTTF design goal. The paper will focus on the technical and engineering aspects of the new design. In addition it will discuss the market needs and expectations, investigate the reliability data of the present reference K508 model; and report the accelerate life test data and the statistical analysis methodology as well as its underlying assumptions and results.
Reliability Impacts in Life Support Architecture and Technology Selection
NASA Technical Reports Server (NTRS)
Lange Kevin E.; Anderson, Molly S.
2012-01-01
Quantitative assessments of system reliability and equivalent system mass (ESM) were made for different life support architectures based primarily on International Space Station technologies. The analysis was applied to a one-year deep-space mission. System reliability was increased by adding redundancy and spares, which added to the ESM. Results were thus obtained allowing a comparison of the ESM for each architecture at equivalent levels of reliability. Although the analysis contains numerous simplifications and uncertainties, the results suggest that achieving necessary reliabilities for deep-space missions will add substantially to the life support ESM and could influence the optimal degree of life support closure. Approaches for reducing reliability impacts were investigated and are discussed.
High duty cycle hard soldered kilowatt laser diode arrays
NASA Astrophysics Data System (ADS)
Klumel, Genady; Karni, Yoram; Oppenheim, Jacob; Berk, Yuri; Shamay, Moshe; Tessler, Renana; Cohen, Shalom
2010-02-01
High-brightness laser diode arrays operating at a duty cycle of 10% - 20% are in ever-increasing demand for the optical pumping of solid state lasers and directed energy applications. Under high duty-cycle operation at 10% - 20%, passive (conductive) cooling is of limited use, while micro-coolers using de-ionized cooling water can considerably degrade device reliability. When designing and developing actively-cooled collimated laser diode arrays for high duty cycle operation, three main problems should be carefully addressed: an effective local and total heat removal, a minimization of packaging-induced and operational stresses, and high-precision fast axis collimation. In this paper, we present a novel laser diode array incorporating a built-in tap water cooling system, all-hard-solder bonded assembly, facet-passivated high-power 940 nm laser bars and tight fast axis collimation. By employing an appropriate layout of water cooling channels, careful choice of packaging materials, proper design of critical parts, and active optics alignment, we have demonstrated actively-cooled collimated laser diode arrays with extended lifetime and reliability, without compromising their efficiency, optical power density, brightness or compactness. Among the key performance benchmarks achieved are: 150 W/bar optical peak power at 10% duty cycle, >50% wallplug efficiency and <1° collimated fast axis divergence. A lifetime of >0.5 Ghots with <2% degradation has been experimentally proven. The laser diode arrays have also been successfully tested under harsh environmental conditions, including thermal cycling between -20°C and 40°C and mechanical shocks at 500g acceleration. The results of both performance and reliability testing bear out the effectiveness and robustness of the manufacturing technology for high duty-cycle laser arrays.
Reliability of risk-adjusted outcomes for profiling hospital surgical quality.
Krell, Robert W; Hozain, Ahmed; Kao, Lillian S; Dimick, Justin B
2014-05-01
Quality improvement platforms commonly use risk-adjusted morbidity and mortality to profile hospital performance. However, given small hospital caseloads and low event rates for some procedures, it is unclear whether these outcomes reliably reflect hospital performance. To determine the reliability of risk-adjusted morbidity and mortality for hospital performance profiling using clinical registry data. A retrospective cohort study was conducted using data from the American College of Surgeons National Surgical Quality Improvement Program, 2009. Participants included all patients (N = 55,466) who underwent colon resection, pancreatic resection, laparoscopic gastric bypass, ventral hernia repair, abdominal aortic aneurysm repair, and lower extremity bypass. Outcomes included risk-adjusted overall morbidity, severe morbidity, and mortality. We assessed reliability (0-1 scale: 0, completely unreliable; and 1, perfectly reliable) for all 3 outcomes. We also quantified the number of hospitals meeting minimum acceptable reliability thresholds (>0.70, good reliability; and >0.50, fair reliability) for each outcome. For overall morbidity, the most common outcome studied, the mean reliability depended on sample size (ie, how high the hospital caseload was) and the event rate (ie, how frequently the outcome occurred). For example, mean reliability for overall morbidity was low for abdominal aortic aneurysm repair (reliability, 0.29; sample size, 25 cases per year; and event rate, 18.3%). In contrast, mean reliability for overall morbidity was higher for colon resection (reliability, 0.61; sample size, 114 cases per year; and event rate, 26.8%). Colon resection (37.7% of hospitals), pancreatic resection (7.1% of hospitals), and laparoscopic gastric bypass (11.5% of hospitals) were the only procedures for which any hospitals met a reliability threshold of 0.70 for overall morbidity. Because severe morbidity and mortality are less frequent outcomes, their mean reliability was lower, and even fewer hospitals met the thresholds for minimum reliability. Most commonly reported outcome measures have low reliability for differentiating hospital performance. This is especially important for clinical registries that sample rather than collect 100% of cases, which can limit hospital case accrual. Eliminating sampling to achieve the highest possible caseloads, adjusting for reliability, and using advanced modeling strategies (eg, hierarchical modeling) are necessary for clinical registries to increase their benchmarking reliability.
The F-12 series aircraft approach to design for control system reliability
NASA Technical Reports Server (NTRS)
Schenk, F. L.; Mcmaster, J. R.
1976-01-01
The F-12 series aircraft control system design philosophy is reviewed as it pertains to functional reliability. The basic control system, i.e., cables, mixer, feel system, trim devices, and hydraulic systems are described and discussed. In addition, the implementation of the redundant stability augmentation system in the F-12 aircraft is described. Finally, the functional reliability record that has been achieved is presented.
Measuring competence in endoscopic sinus surgery.
Syme-Grant, J; White, P S; McAleer, J P G
2008-02-01
Competence based education is currently being introduced into higher surgical training in the UK. Valid and reliable performance assessment tools are essential to ensure competencies are achieved. No such tools have yet been reported in the UK literature. We sought to develop and pilot test an Endoscopic Sinus Surgery Competence Assessment Tool (ESSCAT). The ESSCAT was designed for in-theatre assessment of higher surgical trainees in the UK. The ESSCAT rating matrix was developed through task analysis of ESS procedures. All otolaryngology consultants and specialist registrars in Scotland were given the opportunity to contribute to its refinement. Two cycles of in-theatre testing were used to ensure utility and gather quantitative data on validity and reliability. Videos of trainees performing surgery were used in establishing inter-rater reliability. National consultation, the consensus derived minimum standard of performance, Cronbach's alpha = 0.89 and demonstration of trainee learning (p = 0.027) during the in vivo application of the ESSCAT suggest a high level of validity. Inter-rater reliability was moderate for competence decisions (Cohen's Kappa = 0.5) and good for total scores (Intra-Class Correlation Co-efficient = 0.63). Intra-rater reliability was good for both competence decisions (Kappa = 0.67) and total scores (Kendall's Tau-b = 0.73). The ESSCAT generates a valid and reliable assessment of trainees' in-theatre performance of endoscopic sinus surgery. In conjunction with ongoing evaluation of the instrument we recommend the use of the ESSCAT in higher specialist training in otolaryngology in the UK.
Heroic Reliability Improvement in Manned Space Systems
NASA Technical Reports Server (NTRS)
Jones, Harry W.
2017-01-01
System reliability can be significantly improved by a strong continued effort to identify and remove all the causes of actual failures. Newly designed systems often have unexpected high failure rates which can be reduced by successive design improvements until the final operational system has an acceptable failure rate. There are many causes of failures and many ways to remove them. New systems may have poor specifications, design errors, or mistaken operations concepts. Correcting unexpected problems as they occur can produce large early gains in reliability. Improved technology in materials, components, and design approaches can increase reliability. The reliability growth is achieved by repeatedly operating the system until it fails, identifying the failure cause, and fixing the problem. The failure rate reduction that can be obtained depends on the number and the failure rates of the correctable failures. Under the strong assumption that the failure causes can be removed, the decline in overall failure rate can be predicted. If a failure occurs at the rate of lambda per unit time, the expected time before the failure occurs and can be corrected is 1/lambda, the Mean Time Before Failure (MTBF). Finding and fixing a less frequent failure with the rate of lambda/2 per unit time requires twice as long, time of 1/(2 lambda). Cutting the failure rate in half requires doubling the test and redesign time and finding and eliminating the failure causes.Reducing the failure rate significantly requires a heroic reliability improvement effort.
Gnat, Rafael; Saulicz, Edward; Miądowicz, Barbara
2012-08-01
To investigate intra- and inter-rater reliability of the ultrasound measurement of transversus abdominis (TrA) thickness and thickness change (difference between thickness at rest and during contraction) in asymptomatic, trained subjects. To define the number of repeated measurements that provide acceptable level of reliability. To investigate variability of the measurements over time of 5 days and the reliability of duplicate analysis of images. A single-group repeated-measures design was used to assess reliability. Healthy volunteers (n = 10) were subjected to 1-week training in voluntary activation of TrA. Real-time ultrasound imaging and subsequent measurement of the TrA thickness at rest and during voluntary contraction were repeated on Monday, Wednesday and Friday of the next week. Using a single repeated measurement, intraclass correlation coefficients (ICCs) for TrA thickness were: 0.86-0.95 (intra-rater), 0.86-0.92 (inter-rater); and for TrA thickness change: 0.34-0.56 (intra-rater), 0.47-0.61 (inter-rater). Using the mean of three repeated measurements respective values were: 0.97, 0.96-0.98; and 0.81-0.84, 0.80-0.90. No significant differences were found between mean values of TrA thickness as well as thickness change obtained on three consecutive measurement days. Duplicate analysis of the images was highly reliable with ICCs of 0.89-0.99. Two repeated measurements for TrA thickness and at least three measurements for TrA thickness change are needed to achieve acceptable levels of intra- and inter-rater reliability. In healthy trained volunteers TrA thickness and thickness change are relatively stable parameters over a 5-day period. Duplicate analysis of the same images by two blinded observers is reliable.
Rear-end vision-based collision detection system for motorcyclists
NASA Astrophysics Data System (ADS)
Muzammel, Muhammad; Yusoff, Mohd Zuki; Meriaudeau, Fabrice
2017-05-01
In many countries, the motorcyclist fatality rate is much higher than that of other vehicle drivers. Among many other factors, motorcycle rear-end collisions are also contributing to these biker fatalities. To increase the safety of motorcyclists and minimize their road fatalities, this paper introduces a vision-based rear-end collision detection system. The binary road detection scheme contributes significantly to reduce the negative false detections and helps to achieve reliable results even though shadows and different lane markers are present on the road. The methodology is based on Harris corner detection and Hough transform. To validate this methodology, two types of dataset are used: (1) self-recorded datasets (obtained by placing a camera at the rear end of a motorcycle) and (2) online datasets (recorded by placing a camera at the front of a car). This method achieved 95.1% accuracy for the self-recorded dataset and gives reliable results for the rear-end vehicle detections under different road scenarios. This technique also performs better for the online car datasets. The proposed technique's high detection accuracy using a monocular vision camera coupled with its low computational complexity makes it a suitable candidate for a motorbike rear-end collision detection system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Hsien-Hsin S
The overall objective of this research project is to develop novel architectural techniques as well as system software to achieve a highly secure and intrusion-tolerant computing system. Such system will be autonomous, self-adapting, introspective, with self-healing capability under the circumstances of improper operations, abnormal workloads, and malicious attacks. The scope of this research includes: (1) System-wide, unified introspection techniques for autonomic systems, (2) Secure information-flow microarchitecture, (3) Memory-centric security architecture, (4) Authentication control and its implication to security, (5) Digital right management, (5) Microarchitectural denial-of-service attacks on shared resources. During the period of the project, we developed several architectural techniquesmore » and system software for achieving a robust, secure, and reliable computing system toward our goal.« less
Arico, Pietro; Borghini, Gianluca; Di Flumeri, Gianluca; Colosimo, Alfredo; Graziani, Ilenia; Imbert, Jean-Paul; Granger, Geraud; Benhacene, Railene; Terenzi, Michela; Pozzi, Simone; Babiloni, Fabio
2015-08-01
Machine-learning approaches for mental workload (MW) estimation by using the user brain activity went through a rapid expansion in the last decades. In fact, these techniques allow now to measure the MW with a high time resolution (e.g. few seconds). Despite such advancements, one of the outstanding problems of these techniques regards their ability to maintain a high reliability over time (e.g. high accuracy of classification even across consecutive days) without performing any recalibration procedure. Such characteristic will be highly desirable in real world applications, in which human operators could use such approach without undergo a daily training of the device. In this work, we reported that if a simple classifier is calibrated by using a low number of brain spectral features, between those ones strictly related to the MW (i.e. Frontal and Occipital Theta and Parietal Alpha rhythms), those features will make the classifier performance stable over time. In other words, the discrimination accuracy achieved by the classifier will not degrade significantly across different days (i.e. until one week). The methodology has been tested on twelve Air Traffic Controls (ATCOs) trainees while performing different Air Traffic Management (ATM) scenarios under three different difficulty levels.
Aligning Items and Achievement Levels: A Study Comparing Expert Judgments
ERIC Educational Resources Information Center
Kaliski, Pamela; Huff, Kristen; Barry, Carol
2011-01-01
For educational achievement tests that employ multiple-choice (MC) items and aim to reliably classify students into performance categories, it is critical to design MC items that are capable of discriminating student performance according to the stated achievement levels. This is accomplished, in part, by clearly understanding how item design…
Development and Validation of Economics Achievement Test for Secondary Schools
ERIC Educational Resources Information Center
Eleje, Lydia Ijeoma; Abanobi, Chidiebere Christopher; Obasi, Emma
2017-01-01
Economics achievement test (EAT) for assessing senior secondary two (SS2) achievement in economics was developed and validated in the study. Five research questions guided the study. Twenty and 100 mid-senior secondary (SS2) economics students was used for the pilot testing and reliability check respectively. A sample of 250 students randomly…
ERIC Educational Resources Information Center
Paoloni, Paola Verónica; Vaja, Arabela Beatriz; Muñoz, Verónica Lilian
2014-01-01
Introduction: This paper aims at describing the psychometric features of the Achievement Emotions Questionnaire (AEQ), focusing specifically on the section that measures class emotions. From a theoretical perspective, this instrument was designed based on the control-value theory of achievement emotions. Therefore, a description of the…
High-rate, roll-to-roll nanomanufacturing of flexible systems
NASA Astrophysics Data System (ADS)
Cooper, Khershed P.; Wachter, Ralph F.
2012-10-01
Since the National Nanotechnology Initiative was first announced in 2000, nanotechnology has developed an impressive catalog of nano-scale structures with building-blocks such as nanoparticles, nanotubes, nanorods, nanopillars, and quantum dots. Similarly, there are accompanying materials processes such as, atomic layer deposition, pulsed layer deposition, nanoprinting, nanoimprinting, transfer printing, nanolithography and nanopatterning. One of the challenges of nanomanufacturing is scaling up these processes reliably and affordably. Roll-to-roll manufacturing is a means for scaling up, for increasing throughput. It is high-speed production using a continuous, moving platform such as a web or a flexible substrate. The adoption of roll-to-roll to nanomanufacturing is novel. The goal is to build structures and devices with nano-scale features and specific functionality. The substrate could be a polymer, metal foil, silk, cloth or paper. The materials to build the structures and multi-level devices could be organic, inorganic or biological. Processing could be solution-based, e.g., ink-jet printing, or vacuum-based, e.g., chemical vapor deposition. Products could be electronics, optoelectronics, membranes, catalysts, microfluidics, lab-on-film, filters, etc. By this means, processing of large and conformal areas is achievable. High-throughput translates into low cost, which is the attraction of roll-to-roll nanomanufacturing. There are technical challenges requiring fundamental scientific advances in materials and process development and in manufacturing and system-integration where achieving nano-scale feature size, resolution and accuracy at high speeds can be major hurdles. We will give an overview of roll-to-roll nanomanufacturing with emphasis on the need to understand the material, process and system complexities, the need for instrumentation, measurement, and process control and describe the concept of cyber-enabled nanomanufacturing for reliable and predictable production.
Methods for slow axis beam quality improvement of high power broad area diode lasers
NASA Astrophysics Data System (ADS)
An, Haiyan; Xiong, Yihan; Jiang, Ching-Long J.; Schmidt, Berthold; Treusch, Georg
2014-03-01
For high brightness direct diode laser systems, it is of fundamental importance to improve the slow axis beam quality of the incorporated laser diodes regardless what beam combining technology is applied. To further advance our products in terms of increased brightness at a high power level, we must optimize the slow axis beam quality despite the far field blooming at high current levels. The later is caused predominantly by the built-in index step in combination with the thermal lens effect. Most of the methods for beam quality improvements reported in publications sacrifice the device efficiency and reliable output power. In order to improve the beam quality as well as maintain the efficiency and reliable output power, we investigated methods of influencing local heat generation to reduce the thermal gradient across the slow axis direction, optimizing the built-in index step and discriminating high order modes. Based on our findings, we have combined different methods in our new device design. Subsequently, the beam parameter product (BPP) of a 10% fill factor bar has improved by approximately 30% at 7 W/emitter without efficiency penalty. This technology has enabled fiber coupled high brightness multi-kilowatt direct diode laser systems. In this paper, we will elaborate on the methods used as well as the results achieved.
Low temperature ion source for calutrons
Veach, Allen M.; Bell, Jr., William A.; Howell, Jr., George D.
1981-01-01
A new ion source assembly for calutrons has been provided for the efficient separation of elements having high vapor pressures. The strategic location of cooling pads and improved insulation permits operation of the source at lower temperatures. A vapor valve constructed of graphite and located in a constantly increasing temperature gradient provides reliable control of the vapor flow from the charge bottle to the arc chamber. A pronounced saving in calutron operating time and equipment maintenance has been achieved with the use of the present ion source.
Low temperature ion source for calutrons
Veach, A.M.; Bell, W.A. Jr.; Howell, G.D. Jr.
1979-10-10
A new ion source assembly for calutrons has been provided for the efficient separation of elements having high vapor pressures. The strategic location of cooling pads and improved insulation permits operation of the source at lower temperatures. A vapor valve constructed of graphite and located in a constantly increasing temperature gradient provides reliable control of the vapor flow from the charge bottle to the arc chamber. A pronounced saving in calutron operating time and equipment maintenance has been achieved with the use of the present ion source.
Low Temperature Regenerators for Zero Boil-Off Liquid Hydrogen Pulse Tube Cryocoolers
NASA Technical Reports Server (NTRS)
Salerno, Louis J.; Kashani, Ali; Helvensteijn, Ben; Kittel, Peter; Arnoldm James O. (Technical Monitor)
2002-01-01
Recently, a great deal of attention has been focused on zero boil-off (ZBO) propellant storage as a means of minimizing the launch mass required for long-term exploration missions. A key component of ZBO systems is the cooler. Pulse tube coolers offer the advantage of zero moving mass at the cold head, and recent advances in lightweight, high efficiency cooler technology have paved the way for reliable liquid oxygen (LOx) temperature coolers to be developed which are suitable for flight ZBO systems. Liquid hydrogen (LH2) systems, however, are another matter. For ZBO liquid hydrogen systems, cooling powers of 1-5 watts are required at 20 K. The final development from tier for these coolers is to achieve high efficiency and reliability at lower operating temperatures. Most of the life-limiting issues of flight Stirling and pulse tube coolers are associated with contamination, drive mechanisms, and drive electronics. These problems are well in hand in the present generation coolers. The remaining efficiency and reliability issues reside with the low temperature regenerators. This paper will discuss advances to be made in regenerators for pulse tube LH2 ZBO coolers, present some historical background, and discuss recent progress in regenerator technology development using alloys of erbium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dondero, Rachel Elizabeth
The increased use of Field Programmable Gate Arrays (FPGAs) in critical systems brings new challenges in securing the diversely programmable fabric from cyber-attacks. FPGAs are an inexpensive, efficient, and flexible alternative to Application Specific Integrated Circuits (ASICs), which are becoming increasingly expensive and impractical for low volume manufacturing as technology nodes continue to shrink. Unfortunately, FPGAs are not designed for high security applications, and their high-flexibility lends itself to low security and vulnerability to malicious attacks. Similar to securing an ASIC’s functionality, FPGA programmers can exploit the inherent randomness introduced into hardware structures during fabrication for security applications. Physically Unclonablemore » Functions (PUFs) are one such solution that uses the die specific variability in hardware fabrication for both secret key generation and verification. PUFs strive to be random, unique, and reliable. Throughout recent years many PUF structures have been presented to try and maximize these three design constraints, reliability being the most difficult of the three to achieve. This thesis presents a new PUF structure that combines two elementary PUF concepts (a bi-stable SRAM PUF and a delay-based arbiter PUF) to create a PUF with increased reliability, while maintaining both random and unique qualities. Properties of the new PUF will be discussed as well as the various design modifications that can be made to tweak the desired performance and overhead.« less
A Highly Reliable and Cost-Efficient Multi-Sensor System for Land Vehicle Positioning.
Li, Xu; Xu, Qimin; Li, Bin; Song, Xianghui
2016-05-25
In this paper, we propose a novel positioning solution for land vehicles which is highly reliable and cost-efficient. The proposed positioning system fuses information from the MEMS-based reduced inertial sensor system (RISS) which consists of one vertical gyroscope and two horizontal accelerometers, low-cost GPS, and supplementary sensors and sources. First, pitch and roll angle are accurately estimated based on a vehicle kinematic model. Meanwhile, the negative effect of the uncertain nonlinear drift of MEMS inertial sensors is eliminated by an H∞ filter. Further, a distributed-dual-H∞ filtering (DDHF) mechanism is adopted to address the uncertain nonlinear drift of the MEMS-RISS and make full use of the supplementary sensors and sources. The DDHF is composed of a main H∞ filter (MHF) and an auxiliary H∞ filter (AHF). Finally, a generalized regression neural network (GRNN) module with good approximation capability is specially designed for the MEMS-RISS. A hybrid methodology which combines the GRNN module and the AHF is utilized to compensate for RISS position errors during GPS outages. To verify the effectiveness of the proposed solution, road-test experiments with various scenarios were performed. The experimental results illustrate that the proposed system can achieve accurate and reliable positioning for land vehicles.
Radar-based collision avoidance for unmanned surface vehicles
NASA Astrophysics Data System (ADS)
Zhuang, Jia-yuan; Zhang, Lei; Zhao, Shi-qi; Cao, Jian; Wang, Bo; Sun, Han-bing
2016-12-01
Unmanned surface vehicles (USVs) have become a focus of research because of their extensive applications. To ensure safety and reliability and to perform complex tasks autonomously, USVs are required to possess accurate perception of the environment and effective collision avoidance capabilities. To achieve these, investigation into realtime marine radar target detection and autonomous collision avoidance technologies is required, aiming at solving the problems of noise jamming, uneven brightness, target loss, and blind areas in marine radar images. These technologies should also satisfy the requirements of real-time and reliability related to high navigation speeds of USVs. Therefore, this study developed an embedded collision avoidance system based on the marine radar, investigated a highly real-time target detection method which contains adaptive smoothing algorithm and robust segmentation algorithm, developed a stable and reliable dynamic local environment model to ensure the safety of USV navigation, and constructed a collision avoidance algorithm based on velocity obstacle (V-obstacle) which adjusts the USV's heading and speed in real-time. Sea trials results in multi-obstacle avoidance firstly demonstrate the effectiveness and efficiency of the proposed avoidance system, and then verify its great adaptability and relative stability when a USV sailing in a real and complex marine environment. The obtained results will improve the intelligent level of USV and guarantee the safety of USV independent sailing.
A Highly Reliable and Cost-Efficient Multi-Sensor System for Land Vehicle Positioning
Li, Xu; Xu, Qimin; Li, Bin; Song, Xianghui
2016-01-01
In this paper, we propose a novel positioning solution for land vehicles which is highly reliable and cost-efficient. The proposed positioning system fuses information from the MEMS-based reduced inertial sensor system (RISS) which consists of one vertical gyroscope and two horizontal accelerometers, low-cost GPS, and supplementary sensors and sources. First, pitch and roll angle are accurately estimated based on a vehicle kinematic model. Meanwhile, the negative effect of the uncertain nonlinear drift of MEMS inertial sensors is eliminated by an H∞ filter. Further, a distributed-dual-H∞ filtering (DDHF) mechanism is adopted to address the uncertain nonlinear drift of the MEMS-RISS and make full use of the supplementary sensors and sources. The DDHF is composed of a main H∞ filter (MHF) and an auxiliary H∞ filter (AHF). Finally, a generalized regression neural network (GRNN) module with good approximation capability is specially designed for the MEMS-RISS. A hybrid methodology which combines the GRNN module and the AHF is utilized to compensate for RISS position errors during GPS outages. To verify the effectiveness of the proposed solution, road-test experiments with various scenarios were performed. The experimental results illustrate that the proposed system can achieve accurate and reliable positioning for land vehicles. PMID:27231917
Reliability analysis of laminated CMC components through shell subelement techniques
NASA Technical Reports Server (NTRS)
Starlinger, A.; Duffy, S. F.; Gyekenyesi, J. P.
1992-01-01
An updated version of the integrated design program C/CARES (composite ceramic analysis and reliability evaluation of structures) was developed for the reliability evaluation of CMC laminated shell components. The algorithm is now split in two modules: a finite-element data interface program and a reliability evaluation algorithm. More flexibility is achieved, allowing for easy implementation with various finite-element programs. The new interface program from the finite-element code MARC also includes the option of using hybrid laminates and allows for variations in temperature fields throughout the component.
Pagnuco, Inti Anabela; Revuelta, María Victoria; Bondino, Hernán Gabriel; Brun, Marcel; Ten Have, Arjen
2018-01-01
Protein superfamilies can be divided into subfamilies of proteins with different functional characteristics. Their sequences can be classified hierarchically, which is part of sequence function assignation. Typically, there are no clear subfamily hallmarks that would allow pattern-based function assignation by which this task is mostly achieved based on the similarity principle. This is hampered by the lack of a score cut-off that is both sensitive and specific. HMMER Cut-off Threshold Tool (HMMERCTTER) adds a reliable cut-off threshold to the popular HMMER. Using a high quality superfamily phylogeny, it clusters a set of training sequences such that the cluster-specific HMMER profiles show cluster or subfamily member detection with 100% precision and recall (P&R), thereby generating a specific threshold as inclusion cut-off. Profiles and thresholds are then used as classifiers to screen a target dataset. Iterative inclusion of novel sequences to groups and the corresponding HMMER profiles results in high sensitivity while specificity is maintained by imposing 100% P&R self detection. In three presented case studies of protein superfamilies, classification of large datasets with 100% precision was achieved with over 95% recall. Limits and caveats are presented and explained. HMMERCTTER is a promising protein superfamily sequence classifier provided high quality training datasets are used. It provides a decision support system that aids in the difficult task of sequence function assignation in the twilight zone of sequence similarity. All relevant data and source codes are available from the Github repository at the following URL: https://github.com/BBCMdP/HMMERCTTER.
Pagnuco, Inti Anabela; Revuelta, María Victoria; Bondino, Hernán Gabriel; Brun, Marcel
2018-01-01
Background Protein superfamilies can be divided into subfamilies of proteins with different functional characteristics. Their sequences can be classified hierarchically, which is part of sequence function assignation. Typically, there are no clear subfamily hallmarks that would allow pattern-based function assignation by which this task is mostly achieved based on the similarity principle. This is hampered by the lack of a score cut-off that is both sensitive and specific. Results HMMER Cut-off Threshold Tool (HMMERCTTER) adds a reliable cut-off threshold to the popular HMMER. Using a high quality superfamily phylogeny, it clusters a set of training sequences such that the cluster-specific HMMER profiles show cluster or subfamily member detection with 100% precision and recall (P&R), thereby generating a specific threshold as inclusion cut-off. Profiles and thresholds are then used as classifiers to screen a target dataset. Iterative inclusion of novel sequences to groups and the corresponding HMMER profiles results in high sensitivity while specificity is maintained by imposing 100% P&R self detection. In three presented case studies of protein superfamilies, classification of large datasets with 100% precision was achieved with over 95% recall. Limits and caveats are presented and explained. Conclusions HMMERCTTER is a promising protein superfamily sequence classifier provided high quality training datasets are used. It provides a decision support system that aids in the difficult task of sequence function assignation in the twilight zone of sequence similarity. All relevant data and source codes are available from the Github repository at the following URL: https://github.com/BBCMdP/HMMERCTTER. PMID:29579071
Modern psychometrics for assessing achievement goal orientation: a Rasch analysis.
Muis, Krista R; Winne, Philip H; Edwards, Ordene V
2009-09-01
A program of research is needed that assesses the psychometric properties of instruments designed to quantify students' achievement goal orientations to clarify inconsistencies across previous studies and to provide a stronger basis for future research. We conducted traditional psychometric and modern Rasch-model analyses of the Achievement Goals Questionnaire (AGQ, Elliot & McGregor, 2001) and the Patterns of Adaptive Learning Scale (PALS, Midgley et al., 2000) to provide an in-depth analysis of the two most popular instruments in educational psychology. For Study 1, 217 undergraduate students enrolled in educational psychology courses participated. Thirty-four were male and 181 were female (two did not respond). Participants completed the AGQ in the context of their educational psychology class. For Study 2, 126 undergraduate students enrolled in educational psychology courses participated. Thirty were male and 95 were female (one did not respond). Participants completed the PALS in the context of their educational psychology class. Traditional psychometric assessments of the AGQ and PALS replicated previous studies. For both, reliability estimates ranged from good to very good for raw subscale scores and fit for the models of goal orientations were good. Based on traditional psychometrics, the AGQ and PALS are valid and reliable indicators of achievement goals. Rasch analyses revealed that estimates of reliability for items were very good but respondent ability estimates varied from poor to good for both the AGQ and PALS. These findings indicate that items validly and reliably reflect a group's aggregate goal orientation, but using either instrument to characterize an individual's goal orientation is hazardous.
Tsugawa, Yusuke; Ohbu, Sadayoshi; Cruess, Richard; Cruess, Sylvia; Okubo, Tomoya; Takahashi, Osamu; Tokuda, Yasuharu; Heist, Brian S; Bito, Seiji; Itoh, Toshiyuki; Aoki, Akiko; Chiba, Tsutomu; Fukui, Tsuguya
2011-08-01
Despite the growing importance of and interest in medical professionalism, there is no standardized tool for its measurement. The authors sought to verify the validity, reliability, and generalizability of the Professionalism Mini-Evaluation Exercise (P-MEX), a previously developed and tested tool, in the context of Japanese hospitals. A multicenter, cross-sectional evaluation study was performed to investigate the validity, reliability, and generalizability of the P-MEX in seven Japanese hospitals. In 2009-2010, 378 evaluators (attending physicians, nurses, peers, and junior residents) completed 360-degree assessments of 165 residents and fellows using the P-MEX. The content validity and criterion-related validity were examined, and the construct validity of the P-MEX was investigated by performing confirmatory factor analysis through a structural equation model. The reliability was tested using generalizability analysis. The contents of the P-MEX achieved good acceptance in a preliminary working group, and the poststudy survey revealed that 302 (79.9%) evaluators rated the P-MEX items as appropriate, indicating good content validity. The correlation coefficient between P-MEX scores and external criteria was 0.78 (P < .001), demonstrating good criterion-related validity. Confirmatory factor analysis verified high path coefficient (0.60-0.99) and adequate goodness of fit of the model. The generalizability analysis yielded a high dependability coefficient, suggesting good reliability, except when evaluators were peers or junior residents. Findings show evidence of adequate validity, reliability, and generalizability of the P-MEX in Japanese hospital settings. The P-MEX is the only evaluation tool for medical professionalism verified in both a Western and East Asian cultural context.
Measuring human remains in the field: Grid technique, total station, or MicroScribe?
Sládek, Vladimír; Galeta, Patrik; Sosna, Daniel
2012-09-10
Although three-dimensional (3D) coordinates for human intra-skeletal landmarks are among the most important data that anthropologists have to record in the field, little is known about the reliability of various measuring techniques. We compared the reliability of three techniques used for 3D measurement of human remain in the field: grid technique (GT), total station (TS), and MicroScribe (MS). We measured 365 field osteometric points on 12 skeletal sequences excavated at the Late Medieval/Early Modern churchyard in Všeruby, Czech Republic. We compared intra-observer, inter-observer, and inter-technique variation using mean difference (MD), mean absolute difference (MAD), standard deviation of difference (SDD), and limits of agreement (LA). All three measuring techniques can be used when accepted error ranges can be measured in centimeters. When a range of accepted error measurable in millimeters is needed, MS offers the best solution. TS can achieve the same reliability as does MS, but only when the laser beam is accurately pointed into the center of the prism. When the prism is not accurately oriented, TS produces unreliable data. TS is more sensitive to initialization than is MS. GT measures human skeleton with acceptable reliability for general purposes but insufficiently when highly accurate skeletal data are needed. We observed high inter-technique variation, indicating that just one technique should be used when spatial data from one individual are recorded. Subadults are measured with slightly lower error than are adults. The effect of maximum excavated skeletal length has little practical significance in field recording. When MS is not available, we offer practical suggestions that can help to increase reliability when measuring human skeleton in the field. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Merkow, Ryan P; Hall, Bruce L; Cohen, Mark E; Wang, Xue; Adams, John L; Chow, Warren B; Lawson, Elise H; Bilimoria, Karl Y; Richards, Karen; Ko, Clifford Y
2013-03-01
To develop a reliable, robust, parsimonious, risk-adjusted 30-day composite colectomy outcome measure. A fundamental aspect in the pursuit of high-quality care is the development of valid and reliable performance measures in surgery. Colon resection is associated with appreciable morbidity and mortality and therefore is an ideal quality improvement target. From 2010 American College of Surgeons National Surgical Quality Improvement Program data, patients were identified who underwent colon resection for any indication. A composite outcome of death or any serious morbidity within 30 days of the index operation was established. A 6-predictor, parsimonious model was developed and compared with a more complex model with more variables. National caseload requirements were calculated on the basis of increasing reliability thresholds. From 255 hospitals, 22,346 patients were accrued who underwent a colon resection in 2010, most commonly for neoplasm (46.7%). A mortality or serious morbidity event occurred in 4461 patients (20.0%). At the hospital level, the median composite event rate was 20.7% (interquartile range: 15.8%-26.3%). The parsimonious model performed similarly to the full model (Akaike information criterion: 19,411 vs 18,988), and hospital-level performance comparisons were highly correlated (R = 0.97). At a reliability threshold of 0.4, 56 annual colon resections would be required and achievable at an estimated 42% of US and 69% of American College of Surgeons National Surgical Quality Improvement Program hospitals. This 42% of US hospitals performed approximately 84% of all colon resections in the country in 2008. It is feasible to design a measure with a composite outcome of death or serious morbidity after colon surgery that has a low burden for data collection, has substantial clinical importance, and has acceptable reliability.
Thickness Dependency of Thin Film Samaria Doped Ceria for Oxygen Sensing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanghavi, Rahul P.; Nandasiri, Manjula I.; Kuchibhatla, Satyanarayana V N T
High temperature oxygen sensors are widely used for exhaust gas monitoring in automobiles. This particular study explores the use of thin film single crystalline samaria doped ceria as the oxygen sensing material. Desired signal to noise ratio can be achieved in a material system with high conductivity. From previous studies it is established that 6 atomic percent samarium doping is the optimum concentration for thin film samaria doped ceria to achieve high ionic conductivity. In this study, the conductivity of the 6 atomic percent samaria doped ceria thin film is measured as a function of the sensing film thickness. Hysteresismore » and dynamic response of this sensing platform is tested for a range of oxygen pressures from 0.001 Torr to 100 Torr for temperatures above 673 K. An attempt has been made to understand the physics behind the thickness dependent conductivity behavior of this sensing platform by developing a hypothetical operating model and through COMSOL simulations. This study can be used to identify the parameters required to construct a fast, reliable and compact high temperature oxygen sensor.« less
Applicability of dynamic membrane technology in anaerobic membrane bioreactors.
Ersahin, Mustafa Evren; Ozgun, Hale; Tao, Yu; van Lier, Jules B
2014-01-01
This study investigated the applicability of dynamic membrane technology in anaerobic membrane bioreactors for the treatment of high strength wastewaters. A monofilament woven fabric was used as support material for dynamic membrane formation. An anaerobic dynamic membrane bioreactor (AnDMBR) was operated under a variety of operational conditions, including different sludge retention times (SRTs) of 20 and 40 days in order to determine the effect of SRT on both biological performance and dynamic membrane filtration characteristics. High COD removal efficiencies exceeding 99% were achieved during the operation at both SRTs. Higher filtration resistances were measured during the operation at SRT of 40 days in comparison to SRT of 20 days, applying a stable flux of 2.6 L/m(2) h. The higher filtration resistances coincided with lower extracellular polymeric substances concentration in the bulk sludge at SRT of 40 days, likely resulting in a decreased particle flocculation. Results showed that dynamic membrane technology achieved a stable and high quality permeate and AnDMBRs can be used as a reliable and satisfactory technology for treatment of high strength wastewaters. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Basili, V. R.
1981-01-01
Work on metrics is discussed. Factors that affect software quality are reviewed. Metrics is discussed in terms of criteria achievements, reliability, and fault tolerance. Subjective and objective metrics are distinguished. Product/process and cost/quality metrics are characterized and discussed.
DOT National Transportation Integrated Search
2010-12-01
The purpose of this qualitative case study was to identify the types of obstacles and patterns experienced by a single heavy rail transit agency located in North America that embedded a Reliability Centered Maintenance (RCM) Process. The outcome of t...
Lewicke, Aaron; Sazonov, Edward; Corwin, Michael J; Neuman, Michael; Schuckers, Stephanie
2008-01-01
Reliability of classification performance is important for many biomedical applications. A classification model which considers reliability in the development of the model such that unreliable segments are rejected would be useful, particularly, in large biomedical data sets. This approach is demonstrated in the development of a technique to reliably determine sleep and wake using only the electrocardiogram (ECG) of infants. Typically, sleep state scoring is a time consuming task in which sleep states are manually derived from many physiological signals. The method was tested with simultaneous 8-h ECG and polysomnogram (PSG) determined sleep scores from 190 infants enrolled in the collaborative home infant monitoring evaluation (CHIME) study. Learning vector quantization (LVQ) neural network, multilayer perceptron (MLP) neural network, and support vector machines (SVMs) are tested as the classifiers. After systematic rejection of difficult to classify segments, the models can achieve 85%-87% correct classification while rejecting only 30% of the data. This corresponds to a Kappa statistic of 0.65-0.68. With rejection, accuracy improves by about 8% over a model without rejection. Additionally, the impact of the PSG scored indeterminate state epochs is analyzed. The advantages of a reliable sleep/wake classifier based only on ECG include high accuracy, simplicity of use, and low intrusiveness. Reliability of the classification can be built directly in the model, such that unreliable segments are rejected.
Computational methods for efficient structural reliability and reliability sensitivity analysis
NASA Technical Reports Server (NTRS)
Wu, Y.-T.
1993-01-01
This paper presents recent developments in efficient structural reliability analysis methods. The paper proposes an efficient, adaptive importance sampling (AIS) method that can be used to compute reliability and reliability sensitivities. The AIS approach uses a sampling density that is proportional to the joint PDF of the random variables. Starting from an initial approximate failure domain, sampling proceeds adaptively and incrementally with the goal of reaching a sampling domain that is slightly greater than the failure domain to minimize over-sampling in the safe region. Several reliability sensitivity coefficients are proposed that can be computed directly and easily from the above AIS-based failure points. These probability sensitivities can be used for identifying key random variables and for adjusting design to achieve reliability-based objectives. The proposed AIS methodology is demonstrated using a turbine blade reliability analysis problem.
Baxter, Suzanne D.; Smith, Albert F.; Hitchcock, David B.; Collins, Kathleen L.; Guinn, Caroline H.; Finney, Christopher J.; Royer, Julie A.; Miller, Patricia H.
2015-01-01
Objective To examine test-retest reliability and internal consistency of a 5-question food insecurity survey used in the National Health and Nutrition Examination Survey. Methods Researchers administered the National Health and Nutrition Examination Survey in the classroom to 92 fourth-grade children (74 African American; 48 girls) in 2 sessions 27–30 days apart in spring, 2011. Each classroom administration lasted 5–10 minutes. Results Test-retest reliability was 0.66 (Kendall tau), which is modest. Internal consistency (Cronbach alpha) was .67 and .70 for respective administrations. Food insecurity scores were related to gender (adjusted P = .05) and academic achievement (adjusted P = .004) but not to socioeconomic status or body mass index percentile (binomial regression). On average, boys reported higher food insecurity than girls. Children with lower academic achievement scores reported higher food insecurity than children with higher academic achievement scores. Conclusions and Implications The National Health and Nutrition Examination 5-question survey may be group administered to assess food insecurity efficiently as reported by individual fourth-grade children. PMID:26363937
How reliable are Functional Movement Screening scores? A systematic review of rater reliability.
Moran, Robert W; Schneiders, Anthony G; Major, Katherine M; Sullivan, S John
2016-05-01
Several physical assessment protocols to identify intrinsic risk factors for injury aetiology related to movement quality have been described. The Functional Movement Screen (FMS) is a standardised, field-expedient test battery intended to assess movement quality and has been used clinically in preparticipation screening and in sports injury research. To critically appraise and summarise research investigating the reliability of scores obtained using the FMS battery. Systematic literature review. Systematic search of Google Scholar, Scopus (including ScienceDirect and PubMed), EBSCO (including Academic Search Complete, AMED, CINAHL, Health Source: Nursing/Academic Edition), MEDLINE and SPORTDiscus. Studies meeting eligibility criteria were assessed by 2 reviewers for risk of bias using the Quality Appraisal of Reliability Studies checklist. Overall quality of evidence was determined using van Tulder's levels of evidence approach. 12 studies were appraised. Overall, there was a 'moderate' level of evidence in favour of 'acceptable' (intraclass correlation coefficient ≥0.6) inter-rater and intra-rater reliability for composite scores derived from live scoring. For inter-rater reliability of composite scores derived from video recordings there was 'conflicting' evidence, and 'limited' evidence for intra-rater reliability. For inter-rater reliability based on live scoring of individual subtests there was 'moderate' evidence of 'acceptable' reliability (κ≥0.4) for 4 subtests (Deep Squat, Shoulder Mobility, Active Straight-leg Raise, Trunk Stability Push-up) and 'conflicting' evidence for the remaining 3 (Hurdle Step, In-line Lunge, Rotary Stability). This review found 'moderate' evidence that raters can achieve acceptable levels of inter-rater and intra-rater reliability of composite FMS scores when using live ratings. Overall, there were few high-quality studies, and the quality of several studies was impacted by poor study reporting particularly in relation to rater blinding. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Dandoy, Christopher E; Hausfeld, Jackie; Flesch, Laura; Hawkins, Deanna; Demmel, Kathy; Best, Deanna; Osterkamp, Erin; Bracke, Tracey; Nagarajan, Rajaram; Jodele, Sonata; Holt, Julie; Giaccone, Mary Jo; Davies, Stella M; Kotagal, Uma; Simmons, Jeffrey
2016-08-01
Immunocompromised children are at high risk for central line-associated bloodstream infections (CLABSIs) and its associated morbidity and mortality. Prevention of CLABSIs depends on highly reliable care. Since the summer of 2013, we saw an increase in patient volume and acuity in our centre. Additionally, CLABSIs rates more than tripled during this period. The purpose of this initiative was to rapidly identify and mitigate potential underlying drivers to the increased CLABSI rate. Through small tests of change, we implemented a standard process for daily hygiene; increased awareness of high-risk patients with CLABSI; improved education/assistance for nurses performing high-risk central venous catheter procedures; and developed a system to improve allocation of resources to de-escalate system stress. The CLABSI rate from June 2013 to May 2014 was 2.03 CLABSIs/1000 line days. After implementation of our interventions, we saw a significant decrease in the CLABSI rate to 0.39 CLABSIs/1000 line days (p=0.008). Key processes have become more reliable: 100% of dressing changes are completed with the new two-person standard; daily hygiene adherence has increased from 25% to 70%; 100% of nurses are approached daily by senior nursing for assistance with high-risk procedures; and patients at risk for a CLABSI are identified daily. Stress to a complex system caring for high-risk patients can challenge CLABSI rates. Identifying key processes and executing them reliably can stabilise outcomes during times of system stress. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
NASA/Army Rotorcraft Transmission Research, a Review of Recent Significant Accomplishments
NASA Technical Reports Server (NTRS)
Krantz, Timothy L.
1994-01-01
A joint helicopter transmission research program between NASA Lewis Research Center and the U.S. Army Research Lab has existed since 1970. Research goals are to reduce weight and noise while increasing life, reliability, and safety. These research goals are achieved by the NASA/Army Mechanical Systems Technology Branch through both in-house research and cooperative research projects with university and industry partners. Some recent significant technical accomplishments produced by this cooperative research are reviewed. The following research projects are reviewed: oil-off survivability of tapered roller bearings, design and evaluation of high contact ratio gearing, finite element analysis of spiral bevel gears, computer numerical control grinding of spiral bevel gears, gear dynamics code validation, computer program for life and reliability of helicopter transmissions, planetary gear train efficiency study, and the Advanced Rotorcraft Transmission (ART) program.
The Design and Implementation of Indoor Localization System Using Magnetic Field Based on Smartphone
NASA Astrophysics Data System (ADS)
Liu, J.; Jiang, C.; Shi, Z.
2017-09-01
Sufficient signal nodes are mostly required to implement indoor localization in mainstream research. Magnetic field take advantage of high precision, stable and reliability, and the reception of magnetic field signals is reliable and uncomplicated, it could be realized by geomagnetic sensor on smartphone, without external device. After the study of indoor positioning technologies, choose the geomagnetic field data as fingerprints to design an indoor localization system based on smartphone. A localization algorithm that appropriate geomagnetic matching is designed, and present filtering algorithm and algorithm for coordinate conversion. With the implement of plot geomagnetic fingerprints, the indoor positioning of smartphone without depending on external devices can be achieved. Finally, an indoor positioning system which is based on Android platform is successfully designed, through the experiments, proved the capability and effectiveness of indoor localization algorithm.
The optimal duration of frequency-volume charts related to compliance and reliability.
van Haarst, Ernst P; Bosch, J L H Ruud
2014-03-01
To assess Frequency-volume charts (FVCs) for the yield of additional recorded days and the ideal duration of recording related to compliance and reliability. Of 500 consecutive urologic outpatients willing to complete a 7-day FVC, 378 FVCs were evaluable. During seven consecutive days every voiding time and volume were recorded. Missed entries were indicated with a coded letter, thereby assessing the true frequency and compliance. Reliability is the agreement of the day-to-day FVC parameters with the 7-day FVC pattern. Single-day reliability was assessed and used in the Spearman-Brown formula. FVCs of 228 male and 150 females were evaluated. Mean age was 55.2 years (standard deviation [SD]: 16.2 years), and mean 24-hr urine production was 1,856 ml (SD: 828 ml). The percentage of patients with complete FVCs decreased from 78% on day 2 to 58% on day 7, and dropped below 70% after 4 days. Single-day reliability was r = 0.63 for nocturnal urine production, r = 0.72 for 24-hr urine production, and r = 0.80 for mean voided volume. At 5 days, reliability of 90% was achieved for all parameters. With each additional day, FVCs showed a decrease in compliance and an increase in reliability. At day 3, reliability of 80% was achieved for all FVC parameters, but compliance dropped to 73%. Beyond 5 days, the yield of additional recorded days was limited. We advocate an FVC duration of 3 days, but the duration may be shortened or extended depending on the goal of the FVC. © 2013 Wiley Periodicals, Inc.
A high efficiency C-band internally-matched harmonic tuning GaN power amplifier
NASA Astrophysics Data System (ADS)
Lu, Y.; Zhao, B. C.; Zheng, J. X.; Zhang, H. S.; Zheng, X. F.; Ma, X. H.; Hao, Y.; Ma, P. J.
2016-09-01
In this paper, a high efficiency C-band gallium nitride (GaN) internally-matched power amplifier (PA) is presented. This amplifier consists of 2-chips of self-developed GaN high-electron mobility transistors (HEMTs) with 16 mm total gate width on SiC substrate. New harmonic manipulation circuits are induced both in the input and output matching networks for high efficiency matching at fundamental and 2nd-harmonic frequency, respectively. The developed amplifier has achieved 72.1% power added efficiency (PAE) with 107.4 W output power at 5 GHz. To the best of our knowledge, this amplifier exhibits the highest PAE in C-band GaN HEMT amplifiers with over 100 W output power. Additionally, 1000 hours' aging test reveals high reliability for practical applications.
Developing of an automation for therapy dosimetry systems by using labview software
NASA Astrophysics Data System (ADS)
Aydin, Selim; Kam, Erol
2018-06-01
Traceability, accuracy and consistency of radiation measurements are essential in radiation dosimetry, particularly in radiotherapy, where the outcome of treatments is highly dependent on the radiation dose delivered to patients. Therefore it is very important to provide reliable, accurate and fast calibration services for therapy dosimeters since the radiation dose delivered to a radiotherapy patient is directly related to accuracy and reliability of these devices. In this study, we report the performance of in-house developed computer controlled data acquisition and monitoring software for the commercially available radiation therapy electrometers. LabVIEW® software suite is used to provide reliable, fast and accurate calibration services. The software also collects environmental data such as temperature, pressure and humidity in order to use to use these them in correction factor calculations. By using this software tool, a better control over the calibration process is achieved and the need for human intervention is reduced. This is the first software that can control frequently used dosimeter systems, in radiation thereapy field at hospitals, such as Unidos Webline, Unidos E, Dose-1 and PC Electrometers.
Benchmark analysis of forecasted seasonal temperature over different climatic areas
NASA Astrophysics Data System (ADS)
Giunta, G.; Salerno, R.; Ceppi, A.; Ercolani, G.; Mancini, M.
2015-12-01
From a long-term perspective, an improvement of seasonal forecasting, which is often exclusively based on climatology, could provide a new capability for the management of energy resources in a time scale of just a few months. This paper regards a benchmark analysis in relation to long-term temperature forecasts over Italy in the year 2010, comparing the eni-kassandra meteo forecast (e-kmf®) model, the Climate Forecast System-National Centers for Environmental Prediction (CFS-NCEP) model, and the climatological reference (based on 25-year data) with observations. Statistical indexes are used to understand the reliability of the prediction of 2-m monthly air temperatures with a perspective of 12 weeks ahead. The results show how the best performance is achieved by the e-kmf® system which improves the reliability for long-term forecasts compared to climatology and the CFS-NCEP model. By using the reliable high-performance forecast system, it is possible to optimize the natural gas portfolio and management operations, thereby obtaining a competitive advantage in the European energy market.
Assessment Instrument for Problem-focused Coping. Reliability test of APC. Part 1.
Tollén, A; Ahlström, G
1998-01-01
A new self-report instrument, the Assessment Instrument of Problem-focused Coping (APC) developed from qualitative interviews, is described. This instrument provides knowledge of the patients' own competence in coping with activities of daily living (ADL), the patients' own assessment of what they experience as problems, and the extent to which they are satisfied with their ADL. The purpose of the study was to test the reliability of the instrument with regard to intra-rater reliability and internal consistency. The study group comprised 40 patients with muscular weakness and other symptoms relating to the postpolio syndrome. The result showed an acceptable internal consistency (alpha 0.70), which confirms the construct validity of the instrument. The test-retest showed that the stability over a period of time varied from low to high for a total of 28 items. At the same time, it is evident that the instrument does not achieve the aim of being a good evaluation instrument, because the stability over a period of time was unsatisfactory. The test-retest should be repeated with a larger test group in future research projects.
High resolution optical shaft encoder for motor speed control based on an optical disk pick-up
NASA Astrophysics Data System (ADS)
Yeh, Wei-Hung; Bletscher, Warren; Mansuripur, M.
1998-08-01
Using a three-beam optical pick-up from a compact disk player and a flexible, shaft-mounted diffraction grating, we obtain information about the rotation speed and angular position of the motor's spindle. This information may be used for feedback to the motor for smooth operation. Due to the small size of the focused spot and the built-in auto-focus mechanism of the optical head, the proposed encoder can achieve submicrometer resolution. With high resolution, reliable operation, and low-cost elements, the proposed method is suitable for rotary and linear motion control where accurate positioning of an object is required.
NASA Technical Reports Server (NTRS)
Sallee, G. P.
1973-01-01
The advanced technology requirements for an advanced high speed commercial transport engine are presented. The results of the phase 2 study effort cover the following areas: (1) general review of preliminary engine designs suggested for a future aircraft, (2) presentation of a long range view of airline propulsion system objectives and the research programs in noise, pollution, and design which must be undertaken to achieve the goals presented, (3) review of the impact of propulsion system unreliability and unscheduled maintenance on cost of operation, (4) discussion of the reliability and maintainability requirements and guarantees for future engines.
Step 1: Human System Interface (HSI) Functional Requirements Document (FRD). Version 2
NASA Technical Reports Server (NTRS)
2006-01-01
This Functional Requirements Document (FRD) establishes a minimum set of Human System Interface (HSI) functional requirements to achieve the Access 5 Vision of "operating High Altitude, Long Endurance (HALE) Unmanned Aircraft Systems (UAS) routinely, safely, and reliably in the National Airspace System (NAS)". Basically, it provides what functions are necessary to fly UAS in the NAS. The framework used to identify the appropriate functions was the "Aviate, Navigate, Communicate, and Avoid Hazards" structure identified in the Access 5 FRD. As a result, fifteen high-level functional requirements were developed. In addition, several of them have been decomposed into low-level functional requirements to provide more detail.
Low-cost optical interconnect module for parallel optical data links
NASA Astrophysics Data System (ADS)
Noddings, Chad; Hirsch, Tom J.; Olla, M.; Spooner, C.; Yu, Jason J.
1995-04-01
We have designed, fabricated, and tested a prototype parallel ten-channel unidirectional optical data link. When scaled to production, we project that this technology will satisfy the following market penetration requirements: (1) up to 70 meters transmission distance, (2) at least 1 gigabyte/second data rate, and (3) 0.35 to 0.50 MByte/second volume selling price. These goals can be achieved by means of the assembly innovations described in this paper: a novel alignment method that is integrated with low-cost, few chip module packaging techniques, yielding high coupling and reducing the component count. Furthermore, high coupling efficiency increases projected reliability reducing the driver's power requirements.
Yeom, Da-Young; Jeon, Woojin; Tu, Nguyen Dien Kha; Yeo, So Young; Lee, Sang-Soo; Sung, Bong June; Chang, Hyejung; Lim, Jung Ah; Kim, Heesuk
2015-05-05
For the utilization of graphene in various energy storage and conversion applications, it must be synthesized in bulk with reliable and controllable electrical properties. Although nitrogen-doped graphene shows a high doping efficiency, its electrical properties can be easily affected by oxygen and water impurities from the environment. We here report that boron-doped graphene nanoplatelets with desirable electrical properties can be prepared by the simultaneous reduction and boron-doping of graphene oxide (GO) at a high annealing temperature. B-doped graphene nanoplatelets prepared at 1000 °C show a maximum boron concentration of 6.04 ± 1.44 at %, which is the highest value among B-doped graphenes prepared using various methods. With well-mixed GO and g-B2O3 as the dopant, highly uniform doping is achieved for potentially gram-scale production. In addition, as a proof-of-concept, highly B-doped graphene nanoplatelets were used as an electrode of an electrochemical double-layer capacitor (EDLC) and showed an excellent specific capacitance value of 448 F/g in an aqueous electrolyte without additional conductive additives. We believe that B-doped graphene nanoplatelets can also be used in other applications such as electrocatalyst and nano-electronics because of their reliable and controllable electrical properties regardless of the outer environment.
First Stage of a Highly Reliable Reusable Launch System
NASA Technical Reports Server (NTRS)
Kloesel, Kurt J.; Pickrel, Jonathan B.; Sayles, Emily L.; Wright, Michael; Marriott, Darin; Holland, Leo; Kuznetsov, Stephen
2009-01-01
Electromagnetic launch assist has the potential to provide a highly reliable reusable first stage to a space access system infrastructure at a lower overall cost. This paper explores the benefits of a smaller system that adds the advantages of a high specific impulse air-breathing stage and supersonic launch speeds. The method of virtual specific impulse is introduced as a tool to emphasize the gains afforded by launch assist. Analysis shows launch assist can provide a 278-s virtual specific impulse for a first-stage solid rocket. Additional trajectory analysis demonstrates that a system composed of a launch-assisted first-stage ramjet plus a bipropellant second stage can provide a 48-percent gross lift-off weight reduction versus an all-rocket system. The combination of high-speed linear induction motors and ramjets is identified, as the enabling technologies and benchtop prototypes are investigated. The high-speed response of a standard 60 Hz linear induction motor was tested with a pulse width modulated variable frequency drive to 150 Hz using a 10-lb load, achieving 150 mph. A 300-Hz stator-compensated linear induction motor was constructed and static-tested to 1900 lbf average. A matching ramjet design was developed for use on the 300-Hz linear induction motor.
NASA Astrophysics Data System (ADS)
Yeom, Da-Young; Jeon, Woojin; Tu, Nguyen Dien Kha; Yeo, So Young; Lee, Sang-Soo; Sung, Bong June; Chang, Hyejung; Lim, Jung Ah; Kim, Heesuk
2015-05-01
For the utilization of graphene in various energy storage and conversion applications, it must be synthesized in bulk with reliable and controllable electrical properties. Although nitrogen-doped graphene shows a high doping efficiency, its electrical properties can be easily affected by oxygen and water impurities from the environment. We here report that boron-doped graphene nanoplatelets with desirable electrical properties can be prepared by the simultaneous reduction and boron-doping of graphene oxide (GO) at a high annealing temperature. B-doped graphene nanoplatelets prepared at 1000 °C show a maximum boron concentration of 6.04 ± 1.44 at %, which is the highest value among B-doped graphenes prepared using various methods. With well-mixed GO and g-B2O3 as the dopant, highly uniform doping is achieved for potentially gram-scale production. In addition, as a proof-of-concept, highly B-doped graphene nanoplatelets were used as an electrode of an electrochemical double-layer capacitor (EDLC) and showed an excellent specific capacitance value of 448 F/g in an aqueous electrolyte without additional conductive additives. We believe that B-doped graphene nanoplatelets can also be used in other applications such as electrocatalyst and nano-electronics because of their reliable and controllable electrical properties regardless of the outer environment.
Innovative on board payload optical architecture for high throughput satellites
NASA Astrophysics Data System (ADS)
Baudet, D.; Braux, B.; Prieur, O.; Hughes, R.; Wilkinson, M.; Latunde-Dada, K.; Jahns, J.; Lohmann, U.; Fey, D.; Karafolas, N.
2017-11-01
For the next generation of HighThroughPut (HTP) Telecommunications Satellites, space end users' needs will result in higher link speeds and an increase in the number of channels; up to 512 channels running at 10Gbits/s. By keeping electrical interconnections based on copper, the constraints in term of power dissipation, number of electrical wires and signal integrity will become too demanding. The replacement of the electrical links by optical links is the most adapted solution as it provides high speed links with low power consumption and no EMC/EMI. But replacing all electrical links by optical links of an On Board Payload (OBP) is challenging. It is not simply a matter of replacing electrical components with optical but rather the whole concept and architecture have to be rethought to achieve a high reliability and high performance optical solution. In this context, this paper will present the concept of an Innovative OBP Optical Architecture. The optical architecture was defined to meet the critical requirements of the application: signal speed, number of channels, space reliability, power dissipation, optical signals crossing and components availability. The resulting architecture is challenging and the need for new developments is highlighted. But this innovative optically interconnected architecture will substantially outperform standard electrical ones.
Autonomous Assembly of Modular Structures in Space and on Extraterrestrial Locations
NASA Astrophysics Data System (ADS)
Alhorn, Dean C.
2005-02-01
The new U.S. National Vision for Space Exploration requires many new enabling technologies to accomplish the goals of space commercialization and returning humans to the moon and extraterrestrial environments. Traditionally, flight elements are complete sub-systems requiring humans to complete the integration and assembly. These bulky structures also require the use of heavy launch vehicles to send the units to a desired location. This philosophy necessitates a high degree of safety, numerous space walks at a significant cost. Future space mission costs must be reduced and safety increased to reasonably achieve exploration goals. One proposed concept is the autonomous assembly of space structures. This concept is an affordable, reliable solution to in-space and extraterrestrial assembly. Assembly is autonomously performed when two components join after determining that specifications are correct. Local sensors continue monitor joint integrity post assembly, which is critical for safety and structural reliability. Achieving this concept requires a change in space structure design philosophy and the development of innovative technologies to perform autonomous assembly. Assembly of large space structures will require significant numbers of integrity sensors. Thus simple, low-cost sensors are integral to the success of this concept. This paper addresses these issues and proposes a novel concept for assembling space structures autonomously. Core technologies required to achieve in space assembly are presented. These core technologies are critical to the goal of utilizing space in a cost efficient and safe manner. Additionally, these novel technologies can be applied to other systems both on earth and extraterrestrial environments.
Autonomous Assembly of Modular Structures in Space and on Extraterrestrial Locations
NASA Technical Reports Server (NTRS)
Alhorn, Dean C.
2005-01-01
The new U.S. National Vision for Space Exploration requires many new enabling technologies to accomplish the goals of space commercialization and returning humans to the moon and extraterrestrial environments. Traditionally, flight elements are complete subsystems requiring humans to complete the integration and assembly. These bulky structures also require the use of heavy launch vehicles to send the units to a desired location. This philosophy necessitates a high degree of safety, numerous space walks at a significant cost. Future space mission costs must be reduced and safety increased to reasonably achieve exploration goals. One proposed concept is the autonomous assembly of space structures. This concept is an affordable, reliable solution to in-space and extraterrestrial assembly. Assembly is autonomously performed when two components join after determining that specifications are correct. Local sensors continue monitor joint integrity post assembly, which is critical for safety and structural reliability. Achieving this concept requires a change in space structure design philosophy and the development of innovative technologies to perform autonomous assembly. Assembly of large space structures will require significant numbers of integrity sensors. Thus simple, low-cost sensors are integral to the success of this concept. This paper addresses these issues and proposes a novel concept for assembling space structures autonomously. Core technologies required to achieve in space assembly are presented. These core technologies are critical to the goal of utilizing space in a cost efficient and safe manner. Additionally, these novel technologies can be applied to other systems both on earth and extraterrestrial environments.
Rozen, Warren Matthew; Spychal, Robert T.; Hunter-Smith, David J.
2016-01-01
Background Accurate volumetric analysis is an essential component of preoperative planning in both reconstructive and aesthetic breast procedures towards achieving symmetrization and patient-satisfactory outcome. Numerous comparative studies and reviews of individual techniques have been reported. However, a unifying review of all techniques comparing their accuracy, reliability, and practicality has been lacking. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE, was undertaken. Results Since Bouman’s first description of water displacement method, a range of volumetric assessment techniques have been described: thermoplastic casting, direct anthropomorphic measurement, two-dimensional (2D) imaging, and computed tomography (CT)/magnetic resonance imaging (MRI) scans. However, most have been unreliable, difficult to execute and demonstrate limited practicability. Introduction of 3D surface imaging has revolutionized the field due to its ease of use, fast speed, accuracy, and reliability. However, its widespread use has been limited by its high cost and lack of high level of evidence. Recent developments have unveiled the first web-based 3D surface imaging program, 4D imaging, and 3D printing. Conclusions Despite its importance, an accurate, reliable, and simple breast volumetric analysis tool has been elusive until the introduction of 3D surface imaging technology. However, its high cost has limited its wide usage. Novel adjunct technologies, such as web-based 3D surface imaging program, 4D imaging, and 3D printing, appear promising. PMID:27047788
Reliability Estimation of Parameters of Helical Wind Turbine with Vertical Axis
Dumitrascu, Adela-Eliza; Lepadatescu, Badea; Dumitrascu, Dorin-Ion; Nedelcu, Anisor; Ciobanu, Doina Valentina
2015-01-01
Due to the prolonged use of wind turbines they must be characterized by high reliability. This can be achieved through a rigorous design, appropriate simulation and testing, and proper construction. The reliability prediction and analysis of these systems will lead to identifying the critical components, increasing the operating time, minimizing failure rate, and minimizing maintenance costs. To estimate the produced energy by the wind turbine, an evaluation approach based on the Monte Carlo simulation model is developed which enables us to estimate the probability of minimum and maximum parameters. In our simulation process we used triangular distributions. The analysis of simulation results has been focused on the interpretation of the relative frequency histograms and cumulative distribution curve (ogive diagram), which indicates the probability of obtaining the daily or annual energy output depending on wind speed. The experimental researches consist in estimation of the reliability and unreliability functions and hazard rate of the helical vertical axis wind turbine designed and patented to climatic conditions for Romanian regions. Also, the variation of power produced for different wind speeds, the Weibull distribution of wind probability, and the power generated were determined. The analysis of experimental results indicates that this type of wind turbine is efficient at low wind speed. PMID:26167524
Reliability Estimation of Parameters of Helical Wind Turbine with Vertical Axis.
Dumitrascu, Adela-Eliza; Lepadatescu, Badea; Dumitrascu, Dorin-Ion; Nedelcu, Anisor; Ciobanu, Doina Valentina
2015-01-01
Due to the prolonged use of wind turbines they must be characterized by high reliability. This can be achieved through a rigorous design, appropriate simulation and testing, and proper construction. The reliability prediction and analysis of these systems will lead to identifying the critical components, increasing the operating time, minimizing failure rate, and minimizing maintenance costs. To estimate the produced energy by the wind turbine, an evaluation approach based on the Monte Carlo simulation model is developed which enables us to estimate the probability of minimum and maximum parameters. In our simulation process we used triangular distributions. The analysis of simulation results has been focused on the interpretation of the relative frequency histograms and cumulative distribution curve (ogive diagram), which indicates the probability of obtaining the daily or annual energy output depending on wind speed. The experimental researches consist in estimation of the reliability and unreliability functions and hazard rate of the helical vertical axis wind turbine designed and patented to climatic conditions for Romanian regions. Also, the variation of power produced for different wind speeds, the Weibull distribution of wind probability, and the power generated were determined. The analysis of experimental results indicates that this type of wind turbine is efficient at low wind speed.
Synthesizing cognition in neuromorphic electronic systems
Neftci, Emre; Binas, Jonathan; Rutishauser, Ueli; Chicca, Elisabetta; Indiveri, Giacomo; Douglas, Rodney J.
2013-01-01
The quest to implement intelligent processing in electronic neuromorphic systems lacks methods for achieving reliable behavioral dynamics on substrates of inherently imprecise and noisy neurons. Here we report a solution to this problem that involves first mapping an unreliable hardware layer of spiking silicon neurons into an abstract computational layer composed of generic reliable subnetworks of model neurons and then composing the target behavioral dynamics as a “soft state machine” running on these reliable subnets. In the first step, the neural networks of the abstract layer are realized on the hardware substrate by mapping the neuron circuit bias voltages to the model parameters. This mapping is obtained by an automatic method in which the electronic circuit biases are calibrated against the model parameters by a series of population activity measurements. The abstract computational layer is formed by configuring neural networks as generic soft winner-take-all subnetworks that provide reliable processing by virtue of their active gain, signal restoration, and multistability. The necessary states and transitions of the desired high-level behavior are then easily embedded in the computational layer by introducing only sparse connections between some neurons of the various subnets. We demonstrate this synthesis method for a neuromorphic sensory agent that performs real-time context-dependent classification of motion patterns observed by a silicon retina. PMID:23878215
Vallis, Michael
2013-02-01
The purpose of this article is to operationalize behaviour change counselling skills (motivation enhancement, behaviour modification, emotion management) that facilitate self-management support activities and evaluate the psychometric properties of an expert rater scale, the Behaviour Change Counselling Scale (BCCS). Twenty-one healthcare providers with varying levels of behaviour change counselling training interviewed a simulated patient. Videotapes were independently rated by 3 experts on 2 occasions over 6 months. Data on item/subscale characteristics, interrater and test-retest reliability, preliminary data on construct reliability, were reported. All items of the BCCS performed well with the exception of 3 that were dropped due to infrequent endorsement. Most subscales showed strong psychometric properties. Interrater and test-retest reliability coefficients were uniformly high. Competency scores improved significantly from pre- to posttraining. Behaviour change counselling skills to guide lifestyle interventions can be operationalized and assessed in a reliable and valid manner. The BCCS can be used to guide clinical training in lifestyle counselling by operationalizing the component skills and providing feedback on skill achieved. Further research is needed to establish cut scores for competency and scale construct and criterion validity. Copyright © 2013 Canadian Diabetes Association. Published by Elsevier Inc. All rights reserved.
A forward view on reliable computers for flight control
NASA Technical Reports Server (NTRS)
Goldberg, J.; Wensley, J. H.
1976-01-01
The requirements for fault-tolerant computers for flight control of commercial aircraft are examined; it is concluded that the reliability requirements far exceed those typically quoted for space missions. Examination of circuit technology and alternative computer architectures indicates that the desired reliability can be achieved with several different computer structures, though there are obvious advantages to those that are more economic, more reliable, and, very importantly, more certifiable as to fault tolerance. Progress in this field is expected to bring about better computer systems that are more rigorously designed and analyzed even though computational requirements are expected to increase significantly.
A study of the longevity and operational reliability of Goddard Spacecraft, 1960-1980
NASA Technical Reports Server (NTRS)
Shockey, E. F.
1981-01-01
Compiled data regarding the design lives and lifetimes actually achieved by 104 orbiting satellites launched by the Goddard Spaceflight Center between the years 1960 and 1980 is analyzed. Historical trends over the entire 21 year period are reviewed, and the more recent data is subjected to an examination of several key parameters. An empirical reliability function is derived, and compared with various mathematical models. Data from related studies is also discussed. The results provide insight into the reliability history of Goddard spacecraft an guidance for estimating the reliability of future programs.
2014-01-01
Background Multiple mini-interviews (MMIs) are a valuable tool in medical school selection due to their broad acceptance and promising psychometric properties. With respect to the high expenses associated with this procedure, the discussion about its feasibility should be extended to cost-effectiveness issues. Methods Following a pilot test of MMIs for medical school admission at Hamburg University in 2009 (HAM-Int), we took several actions to improve reliability and to reduce costs of the subsequent procedure in 2010. For both years, we assessed overall and inter-rater reliabilities based on multilevel analyses. Moreover, we provide a detailed specification of costs, as well as an extrapolation of the interrelation of costs, reliability, and the setup of the procedure. Results The overall reliability of the initial 2009 HAM-Int procedure with twelve stations and an average of 2.33 raters per station was ICC=0.75. Following the improvement actions, in 2010 the ICC remained stable at 0.76, despite the reduction of the process to nine stations and 2.17 raters per station. Moreover, costs were cut down from $915 to $495 per candidate. With the 2010 modalities, we could have reached an ICC of 0.80 with 16 single rater stations ($570 per candidate). Conclusions With respect to reliability and cost-efficiency, it is generally worthwhile to invest in scoring, rater training and scenario development. Moreover, it is more beneficial to increase the number of stations instead of raters within stations. However, if we want to achieve more than 80 % reliability, a minor improvement is paid with skyrocketing costs. PMID:24645665
Paesani, Daniel A; Guarda-Nardini, Luca; Gelos, Carlota; Salmaso, Luigi; Manfredini, Daniele
2014-03-01
The aim was to answer the clinical research question: is incisal/occlusal tooth wear assessment on dental casts performed by five professionals with expertise in different fields of dentistry reliable? Five examiners with different fields of expertise in the dental profession assessed tooth wear on dental casts of 45 subjects, based on a six-degree rating of incisal/occlusal wear. After a calibration meeting, the examiners evaluated the casts individually and various issues concerning interexaminer agreement and reliability were assessed. A total of 872 teeth were evaluated. The five examiners agreed only for the rating of 6.6% of the teeth. The teeth with the highest percentage of agreement were the premolars. Pairwise comparison of the assessments of the examiners #1 (bruxism expert), #2 (orthodontist), #3 (temporomandibular disorders [TMD] and occlusion expert), #4 (dental nurse) showed fair to moderate agreement, with κ-values ranging from 0.306 to 0.577, whilst the examiner #5 (lab technician) achieved low interexaminer reliability values with all the other four examiners. The interexaminer reliability of tooth wear assessment on dental casts performed by five professionals with expertise in different fields of dentistry is highly variable. General practitioners should keep in mind that consensus decisions by the examiners and assessment by raters belonging to the same dental discipline are recommended strategies to increase the reliability of tooth wear evaluation in the clinical setting. This investigation adds to the literature suggesting that, in a clinical setting, a single examiner's assessment of tooth wear on dental casts does not have optimal reliability and that it may be source of internal validity problems in the research setting.
Limitations of Reliability for Long-Endurance Human Spaceflight
NASA Technical Reports Server (NTRS)
Owens, Andrew C.; de Weck, Olivier L.
2016-01-01
Long-endurance human spaceflight - such as missions to Mars or its moons - will present a never-before-seen maintenance logistics challenge. Crews will be in space for longer and be farther way from Earth than ever before. Resupply and abort options will be heavily constrained, and will have timescales much longer than current and past experience. Spare parts and/or redundant systems will have to be included to reduce risk. However, the high cost of transportation means that this risk reduction must be achieved while also minimizing mass. The concept of increasing system and component reliability is commonly discussed as a means to reduce risk and mass by reducing the probability that components will fail during a mission. While increased reliability can reduce maintenance logistics mass requirements, the rate of mass reduction decreases over time. In addition, reliability growth requires increased test time and cost. This paper assesses trends in test time requirements, cost, and maintenance logistics mass savings as a function of increase in Mean Time Between Failures (MTBF) for some or all of the components in a system. In general, reliability growth results in superlinear growth in test time requirements, exponential growth in cost, and sublinear benefits (in terms of logistics mass saved). These trends indicate that it is unlikely that reliability growth alone will be a cost-effective approach to maintenance logistics mass reduction and risk mitigation for long-endurance missions. This paper discusses these trends as well as other options to reduce logistics mass such as direct reduction of part mass, commonality, or In-Space Manufacturing (ISM). Overall, it is likely that some combination of all available options - including reliability growth - will be required to reduce mass and mitigate risk for future deep space missions.
Flight control electronics reliability/maintenance study
NASA Technical Reports Server (NTRS)
Dade, W. W.; Edwards, R. H.; Katt, G. T.; Mcclellan, K. L.; Shomber, H. A.
1977-01-01
Collection and analysis of data are reported that concern the reliability and maintenance experience of flight control system electronics currently in use on passenger carrying jet aircraft. Two airlines B-747 airplane fleets were analyzed to assess the component reliability, system functional reliability, and achieved availability of the CAT II configuration flight control system. Also assessed were the costs generated by this system in the categories of spare equipment, schedule irregularity, and line and shop maintenance. The results indicate that although there is a marked difference in the geographic location and route pattern between the airlines studied, there is a close similarity in the reliability and the maintenance costs associated with the flight control electronics.
NASA Astrophysics Data System (ADS)
Jende, Phillipp; Nex, Francesco; Gerke, Markus; Vosselman, George
2018-07-01
Mobile Mapping (MM) solutions have become a significant extension to traditional data acquisition methods over the last years. Independently from the sensor carried by a platform, may it be laser scanners or cameras, high-resolution data postings are opposing a poor absolute localisation accuracy in urban areas due to GNSS occlusions and multipath effects. Potentially inaccurate position estimations are propagated by IMUs which are furthermore prone to drift effects. Thus, reliable and accurate absolute positioning on a par with MM's high-quality data remains an open issue. Multiple and diverse approaches have shown promising potential to mitigate GNSS errors in urban areas, but cannot achieve decimetre accuracy, require manual effort, or have limitations with respect to costs and availability. This paper presents a fully automatic approach to support the correction of MM imaging data based on correspondences with airborne nadir images. These correspondences can be employed to correct the MM platform's orientation by an adjustment solution. Unlike MM as such, aerial images do not suffer from GNSS occlusions, and their accuracy is usually verified by employing well-established methods using ground control points. However, a registration between MM and aerial images is a non-standard matching scenario, and requires several strategies to yield reliable and accurate correspondences. Scale, perspective and content strongly vary between both image sources, thus traditional feature matching methods may fail. To this end, the registration process is designed to focus on common and clearly distinguishable elements, such as road markings, manholes, or kerbstones. With a registration accuracy of about 98%, reliable tie information between MM and aerial data can be derived. Even though, the adjustment strategy is not covered in its entirety in this paper, accuracy results after adjustment will be presented. It will be shown that a decimetre accuracy is well achievable in a real data test scenario.
NASA Astrophysics Data System (ADS)
Gorzelic, P.; Schiff, S. J.; Sinha, A.
2013-04-01
Objective. To explore the use of classical feedback control methods to achieve an improved deep brain stimulation (DBS) algorithm for application to Parkinson's disease (PD). Approach. A computational model of PD dynamics was employed to develop model-based rational feedback controller design. The restoration of thalamocortical relay capabilities to patients suffering from PD is formulated as a feedback control problem with the DBS waveform serving as the control input. Two high-level control strategies are tested: one that is driven by an online estimate of thalamic reliability, and another that acts to eliminate substantial decreases in the inhibition from the globus pallidus interna (GPi) to the thalamus. Control laws inspired by traditional proportional-integral-derivative (PID) methodology are prescribed for each strategy and simulated on this computational model of the basal ganglia network. Main Results. For control based upon thalamic reliability, a strategy of frequency proportional control with proportional bias delivered the optimal control achieved for a given energy expenditure. In comparison, control based upon synaptic inhibitory output from the GPi performed very well in comparison with those of reliability-based control, with considerable further reduction in energy expenditure relative to that of open-loop DBS. The best controller performance was amplitude proportional with derivative control and integral bias, which is full PID control. We demonstrated how optimizing the three components of PID control is feasible in this setting, although the complexity of these optimization functions argues for adaptive methods in implementation. Significance. Our findings point to the potential value of model-based rational design of feedback controllers for Parkinson's disease.
Gorzelic, P; Schiff, S J; Sinha, A
2013-04-01
To explore the use of classical feedback control methods to achieve an improved deep brain stimulation (DBS) algorithm for application to Parkinson's disease (PD). A computational model of PD dynamics was employed to develop model-based rational feedback controller design. The restoration of thalamocortical relay capabilities to patients suffering from PD is formulated as a feedback control problem with the DBS waveform serving as the control input. Two high-level control strategies are tested: one that is driven by an online estimate of thalamic reliability, and another that acts to eliminate substantial decreases in the inhibition from the globus pallidus interna (GPi) to the thalamus. Control laws inspired by traditional proportional-integral-derivative (PID) methodology are prescribed for each strategy and simulated on this computational model of the basal ganglia network. For control based upon thalamic reliability, a strategy of frequency proportional control with proportional bias delivered the optimal control achieved for a given energy expenditure. In comparison, control based upon synaptic inhibitory output from the GPi performed very well in comparison with those of reliability-based control, with considerable further reduction in energy expenditure relative to that of open-loop DBS. The best controller performance was amplitude proportional with derivative control and integral bias, which is full PID control. We demonstrated how optimizing the three components of PID control is feasible in this setting, although the complexity of these optimization functions argues for adaptive methods in implementation. Our findings point to the potential value of model-based rational design of feedback controllers for Parkinson's disease.
A Laboratory Study on the Reliability Estimations of the Mini-CEX
ERIC Educational Resources Information Center
de Lima, Alberto Alves; Conde, Diego; Costabel, Juan; Corso, Juan; Van der Vleuten, Cees
2013-01-01
Reliability estimations of workplace-based assessments with the mini-CEX are typically based on real-life data. Estimations are based on the assumption of local independence: the object of the measurement should not be influenced by the measurement itself and samples should be completely independent. This is difficult to achieve. Furthermore, the…
ERIC Educational Resources Information Center
Hilsenroth, Mark J.; Eudell-Simmons, Erin M.; DeFife, Jared A.; Charnas, Jocelyn W.
2007-01-01
This study investigates the reliability, validity, and diagnostic efficiency of the Rorschach Perceptual-Thinking Index (PTI) in relation to the accurate identification of psychotic disorder (PTD) patients. The PTI is a revision of the Rorschach Schizophrenia Index (SCZI), designed to achieve several criteria, including an increase in the…
Measurement error: Implications for diagnosis and discrepancy models of developmental dyslexia.
Cotton, Sue M; Crewther, David P; Crewther, Sheila G
2005-08-01
The diagnosis of developmental dyslexia (DD) is reliant on a discrepancy between intellectual functioning and reading achievement. Discrepancy-based formulae have frequently been employed to establish the significance of the difference between 'intelligence' and 'actual' reading achievement. These formulae, however, often fail to take into consideration test reliability and the error associated with a single test score. This paper provides an illustration of the potential effects that test reliability and measurement error can have on the diagnosis of dyslexia, with particular reference to discrepancy models. The roles of reliability and standard error of measurement (SEM) in classic test theory are also briefly reviewed. This is followed by illustrations of how SEM and test reliability can aid with the interpretation of a simple discrepancy-based formula of DD. It is proposed that a lack of consideration of test theory in the use of discrepancy-based models of DD can lead to misdiagnosis (both false positives and false negatives). Further, misdiagnosis in research samples affects reproducibility and generalizability of findings. This in turn, may explain current inconsistencies in research on the perceptual, sensory, and motor correlates of dyslexia.
NASA Astrophysics Data System (ADS)
Kosugi, Akito; Takemi, Mitsuaki; Tia, Banty; Castagnola, Elisa; Ansaldo, Alberto; Sato, Kenta; Awiszus, Friedemann; Seki, Kazuhiko; Ricci, Davide; Fadiga, Luciano; Iriki, Atsushi; Ushiba, Junichi
2018-06-01
Objective. Motor map has been widely used as an indicator of motor skills and learning, cortical injury, plasticity, and functional recovery. Cortical stimulation mapping using epidural electrodes is recently adopted for animal studies. However, several technical limitations still remain. Test-retest reliability of epidural cortical stimulation (ECS) mapping has not been examined in detail. Many previous studies defined evoked movements and motor thresholds by visual inspection, and thus, lacked quantitative measurements. A reliable and quantitative motor map is important to elucidate the mechanisms of motor cortical reorganization. The objective of the current study was to perform reliable ECS mapping of motor representations based on the motor thresholds, which were stochastically estimated by motor evoked potentials and chronically implanted micro-electrocorticographical (µECoG) electrode arrays, in common marmosets. Approach. ECS was applied using the implanted µECoG electrode arrays in three adult common marmosets under awake conditions. Motor evoked potentials were recorded through electromyographical electrodes implanted in upper limb muscles. The motor threshold was calculated through a modified maximum likelihood threshold-hunting algorithm fitted with the recorded data from marmosets. Further, a computer simulation confirmed reliability of the algorithm. Main results. Computer simulation suggested that the modified maximum likelihood threshold-hunting algorithm enabled to estimate motor threshold with acceptable precision. In vivo ECS mapping showed high test-retest reliability with respect to the excitability and location of the cortical forelimb motor representations. Significance. Using implanted µECoG electrode arrays and a modified motor threshold-hunting algorithm, we were able to achieve reliable motor mapping in common marmosets with the ECS system.
Kosugi, Akito; Takemi, Mitsuaki; Tia, Banty; Castagnola, Elisa; Ansaldo, Alberto; Sato, Kenta; Awiszus, Friedemann; Seki, Kazuhiko; Ricci, Davide; Fadiga, Luciano; Iriki, Atsushi; Ushiba, Junichi
2018-06-01
Motor map has been widely used as an indicator of motor skills and learning, cortical injury, plasticity, and functional recovery. Cortical stimulation mapping using epidural electrodes is recently adopted for animal studies. However, several technical limitations still remain. Test-retest reliability of epidural cortical stimulation (ECS) mapping has not been examined in detail. Many previous studies defined evoked movements and motor thresholds by visual inspection, and thus, lacked quantitative measurements. A reliable and quantitative motor map is important to elucidate the mechanisms of motor cortical reorganization. The objective of the current study was to perform reliable ECS mapping of motor representations based on the motor thresholds, which were stochastically estimated by motor evoked potentials and chronically implanted micro-electrocorticographical (µECoG) electrode arrays, in common marmosets. ECS was applied using the implanted µECoG electrode arrays in three adult common marmosets under awake conditions. Motor evoked potentials were recorded through electromyographical electrodes implanted in upper limb muscles. The motor threshold was calculated through a modified maximum likelihood threshold-hunting algorithm fitted with the recorded data from marmosets. Further, a computer simulation confirmed reliability of the algorithm. Computer simulation suggested that the modified maximum likelihood threshold-hunting algorithm enabled to estimate motor threshold with acceptable precision. In vivo ECS mapping showed high test-retest reliability with respect to the excitability and location of the cortical forelimb motor representations. Using implanted µECoG electrode arrays and a modified motor threshold-hunting algorithm, we were able to achieve reliable motor mapping in common marmosets with the ECS system.
Everett, Tobias C; Ng, Elaine; Power, Daniel; Marsh, Christopher; Tolchard, Stephen; Shadrina, Anna; Bould, Matthew D
2013-12-01
The use of simulation-based assessments for high-stakes physician examinations remains controversial. The Managing Emergencies in Paediatric Anaesthesia course uses simulation to teach evidence-based management of anesthesia crises to trainee anesthetists in the United Kingdom (UK) and Canada. In this study, we investigated the feasibility and reliability of custom-designed scenario-specific performance checklists and a global rating scale (GRS) assessing readiness for independent practice. After research ethics board approval, subjects were videoed managing simulated pediatric anesthesia crises in a single Canadian teaching hospital. Each subject was randomized to two of six different scenarios. All 60 scenarios were subsequently rated by four blinded raters (two in the UK, two in Canada) using the checklists and GRS. The actual and predicted reliability of the tools was calculated for different numbers of raters using the intraclass correlation coefficient (ICC) and the Spearman-Brown prophecy formula. Average measures ICCs ranged from 'substantial' to 'near perfect' (P ≤ 0.001). The reliability of the checklists and the GRS was similar. Single measures ICCs showed more variability than average measures ICC. At least two raters would be required to achieve acceptable reliability. We have established the reliability of a GRS to assess the management of simulated crisis scenarios in pediatric anesthesia, and this tool is feasible within the setting of a research study. The global rating scale allows raters to make a judgement regarding a participant's readiness for independent practice. These tools may be used in the future research examining simulation-based assessment. © 2013 John Wiley & Sons Ltd.
Vadose zone flow convergence test suite
DOE Office of Scientific and Technical Information (OSTI.GOV)
Butcher, B. T.
Performance Assessment (PA) simulations for engineered disposal systems at the Savannah River Site involve highly contrasting materials and moisture conditions at and near saturation. These conditions cause severe convergence difficulties that typically result in unacceptable convergence or long simulation times or excessive analyst effort. Adequate convergence is usually achieved in a trial-anderror manner by applying under-relaxation to the Saturation or Pressure variable, in a series of everdecreasing RELAxation values. SRNL would like a more efficient scheme implemented inside PORFLOW to achieve flow convergence in a more reliable and efficient manner. To this end, a suite of test problems that illustratemore » these convergence problems is provided to facilitate diagnosis and development of an improved convergence strategy. The attached files are being transmitted to you describing the test problem and proposed resolution.« less
CO2 laser therapy of rhinophyma
NASA Astrophysics Data System (ADS)
Voigt, Peggy; Jovanovic, Sergije; Sedlmaier, Benedikt W.
2000-06-01
Laser treatment of skin changes has become common practice in recent years. High absorption of the CO2 laser wavelength in water is responsible for its low penetration dpt in biological tissue. Shortening the tissue exposure time minimizes thermic side effects of laser radiation such as carbonization and coagulation. This can be achieved with scanner systems that move the focused laser beam over a defined area by microprocessor-controlled rapidly rotating mirrors. This enables controlled and reliable removal of certain dermal lesions, particularly hypertrophic scars, scars after common acne, wrinkles and rhinophyma. Laser ablation of rhinophyma is a stress-minimizing procedure for the surgeon and the patient, since it is nearly bloodless and can be performed under local anaesthesia. Cosmetically favorable reepithelization of the lasered surfaces is achieved within a very short period of time.
ERIC Educational Resources Information Center
Kara, Filiz; Celikler, Dilek
2015-01-01
For "Matter Changing" unit included in the Secondary School 5th Grade Science Program, it is intended to develop a test conforming the gains described in the program, and that can determine students' achievements. For this purpose, a multiple-choice test of 48 questions is arranged, consisting of 8 questions for each gain included in the…
ERIC Educational Resources Information Center
Simmons, Deborah C.; And Others
1995-01-01
Examined effects of explicit teaching and peer tutoring on reading achievement of learning-disabled students and nondisabled, low-performing readers in academically integrated classrooms. Found that explicit-teaching students did not achieve reliably better than controls; students in the explicit teaching plus peer tutoring condition scored higher…
Time frequency analysis of olfactory induced EEG-power change.
Schriever, Valentin Alexander; Han, Pengfei; Weise, Stefanie; Hösel, Franziska; Pellegrino, Robert; Hummel, Thomas
2017-01-01
The objective of the present study was to investigate the usefulness of time-frequency analysis (TFA) of olfactory-induced EEG change with a low-cost, portable olfactometer in the clinical investigation of smell function. A total of 78 volunteers participated. The study was composed of three parts where olfactory stimuli were presented using a custom-built olfactometer. Part I was designed to optimize the stimulus as well as the recording conditions. In part II EEG-power changes after olfactory/trigeminal stimulation were compared between healthy participants and patients with olfactory impairment. In Part III the test-retest reliability of the method was evaluated in healthy subjects. Part I indicated that the most effective paradigm for stimulus presentation was cued stimulus, with an interstimulus interval of 18-20s at a stimulus duration of 1000ms with each stimulus quality presented 60 times in blocks of 20 stimuli each. In Part II we found that central processing of olfactory stimuli analyzed by TFA differed significantly between healthy controls and patients even when controlling for age. It was possible to reliably distinguish patients with olfactory impairment from healthy individuals at a high degree of accuracy (healthy controls vs anosmic patients: sensitivity 75%; specificity 89%). In addition we could show a good test-retest reliability of TFA of chemosensory induced EEG-power changes in Part III. Central processing of olfactory stimuli analyzed by TFA reliably distinguishes patients with olfactory impairment from healthy individuals at a high degree of accuracy. Importantly this can be achieved with a simple olfactometer.
Context, culture and (non-verbal) communication affect handover quality.
Frankel, Richard M; Flanagan, Mindy; Ebright, Patricia; Bergman, Alicia; O'Brien, Colleen M; Franks, Zamal; Allen, Andrew; Harris, Angela; Saleem, Jason J
2012-12-01
Transfers of care, also known as handovers, remain a substantial patient safety risk. Although research on handovers has been done since the 1980s, the science is incomplete. Surprisingly few interventions have been rigorously evaluated and, of those that have, few have resulted in long-term positive change. Researchers, both in medicine and other high reliability industries, agree that face-to-face handovers are the most reliable. It is not clear, however, what the term face-to-face means in actual practice. We studied the use of non-verbal behaviours, including gesture, posture, bodily orientation, facial expression, eye contact and physical distance, in the delivery of information during face-to-face handovers. To address this question and study the role of non-verbal behaviour on the quality and accuracy of handovers, we videotaped 52 nursing, medicine and surgery handovers covering 238 patients. Videotapes were analysed using immersion/crystallisation methods of qualitative data analysis. A team of six researchers met weekly for 18 months to view videos together using a consensus-building approach. Consensus was achieved on verbal, non-verbal, and physical themes and patterns observed in the data. We observed four patterns of non-verbal behaviour (NVB) during handovers: (1) joint focus of attention; (2) 'the poker hand'; (3) parallel play and (4) kerbside consultation. In terms of safety, joint focus of attention was deemed to have the best potential for high quality and reliability; however, it occurred infrequently, creating opportunities for education and improvement. Attention to patterns of NVB in face-to-face handovers coupled with education and practice can improve quality and reliability.
Characterizing reliability in a product/process design-assurance program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kerscher, W.J. III; Booker, J.M.; Bement, T.R.
1997-10-01
Over the years many advancing techniques in the area of reliability engineering have surfaced in the military sphere of influence, and one of these techniques is Reliability Growth Testing (RGT). Private industry has reviewed RGT as part of the solution to their reliability concerns, but many practical considerations have slowed its implementation. It`s objective is to demonstrate the reliability requirement of a new product with a specified confidence. This paper speaks directly to that objective but discusses a somewhat different approach to achieving it. Rather than conducting testing as a continuum and developing statistical confidence bands around the results, thismore » Bayesian updating approach starts with a reliability estimate characterized by large uncertainty and then proceeds to reduce the uncertainty by folding in fresh information in a Bayesian framework.« less
A High Power Density Power System Electronics for NASA's Lunar Reconnaissance Orbiter
NASA Technical Reports Server (NTRS)
Hernandez-Pellerano, A.; Stone, R.; Travis, J.; Kercheval, B.; Alkire, G.; Ter-Minassian, V.
2009-01-01
A high power density, modular and state-of-the-art Power System Electronics (PSE) has been developed for the Lunar Reconnaissance Orbiter (LRO) mission. This paper addresses the hardware architecture and performance, the power handling capabilities, and the fabrication technology. The PSE was developed by NASA s Goddard Space Flight Center (GSFC) and is the central location for power handling and distribution of the LRO spacecraft. The PSE packaging design manages and distributes 2200W of solar array input power in a volume less than a cubic foot. The PSE architecture incorporates reliable standard internal and external communication buses, solid state circuit breakers and LiIon battery charge management. Although a single string design, the PSE achieves high reliability by elegantly implementing functional redundancy and internal fault detection and correction. The PSE has been environmentally tested and delivered to the LRO spacecraft for the flight Integration and Test. This modular design is scheduled to flight in early 2009 on board the LRO and Lunar Crater Observation and Sensing Satellite (LCROSS) spacecrafts and is the baseline architecture for future NASA missions such as Global Precipitation Measurement (GPM) and Magnetospheric MultiScale (MMS).
Sikorsky Aircraft Advanced Rotorcraft Transmission (ART) program
NASA Technical Reports Server (NTRS)
Kish, Jules G.
1993-01-01
The objectives of the Advanced Rotorcraft Transmission program were to achieve a 25 percent weight reduction, a 10 dB noise reduction, and a 5,000 hour mean time between removals (MTBR). A three engine Army Cargo Aircraft (ACA) of 85,000 pounds gross weight was used as the baseline. Preliminary designs were conducted of split path and split torque transmissions to evaluate weight, reliability, and noise. A split path gearbox was determined to be 23 percent lighter, greater than 10 dB quieter, and almost four times more reliable than the baseline two stage planetary design. Detail design studies were conducted of the chosen split path configuration, and drawings were produced of a 1/2 size gearbox consisting of a single engine path of the split path section. Fabrication and testing was then conducted on the 1/2 size gearbox. The 1/2 size gearbox testing proved that the concept of the split path gearbox with high reduction ratio double helical output gear was sound. The improvements were attributed to extensive use of composites, spring clutches, advanced high hot hardness gear steels, the split path configuration itself, high reduction ratio, double helical gearing on the output stage, elastomeric load sharing devices, and elimination of accessory drives.
AlKhalidi, Bashar A; Shtaiwi, Majed; AlKhatib, Hatim S; Mohammad, Mohammad; Bustanji, Yasser
2008-01-01
A fast and reliable method for the determination of repaglinide is highly desirable to support formulation screening and quality control. A first-derivative UV spectroscopic method was developed for the determination of repaglinide in tablet dosage form and for dissolution testing. First-derivative UV absorbance was measured at 253 nm. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ) in comparison to the U.S. Pharmacopeia (USP) column high-performance liquid chromatographic (HPLC) method. The first-derivative UV spectrophotometric method showed excellent linearity [correlation coefficient (r) = 0.9999] in the concentration range of 1-35 microg/mL and precision (relative standard deviation < 1.5%). The LOD and LOQ were 0.23 and 0.72 microg/mL, respectively, and good recoveries were achieved (98-101.8%). Statistical comparison of results of the first-derivative UV spectrophotometric and the USP HPLC methods using the t-test showed that there was no significant difference between the 2 methods. Additionally, the method was successfully used for the dissolution test of repaglinide and was found to be reliable, simple, fast, and inexpensive.
High-resolution motion-compensated imaging photoplethysmography for remote heart rate monitoring
NASA Astrophysics Data System (ADS)
Chung, Audrey; Wang, Xiao Yu; Amelard, Robert; Scharfenberger, Christian; Leong, Joanne; Kulinski, Jan; Wong, Alexander; Clausi, David A.
2015-03-01
We present a novel non-contact photoplethysmographic (PPG) imaging system based on high-resolution video recordings of ambient reflectance of human bodies that compensates for body motion and takes advantage of skin erythema fluctuations to improve measurement reliability for the purpose of remote heart rate monitoring. A single measurement location for recording the ambient reflectance is automatically identified on an individual, and the motion for the location is determined over time via measurement location tracking. Based on the determined motion information motion-compensated reflectance measurements at different wavelengths for the measurement location can be acquired, thus providing more reliable measurements for the same location on the human over time. The reflectance measurement is used to determine skin erythema fluctuations over time, resulting in the capture of a PPG signal with a high signal-to-noise ratio. To test the efficacy of the proposed system, a set of experiments involving human motion in a front-facing position were performed under natural ambient light. The experimental results demonstrated that skin erythema fluctuations can achieve noticeably improved average accuracy in heart rate measurement when compared to previously proposed non-contact PPG imaging systems.
The NASA Advanced Space Power Systems Project
NASA Technical Reports Server (NTRS)
Mercer, Carolyn R.; Hoberecht, Mark A.; Bennett, William R.; Lvovich, Vadim F.; Bugga, Ratnakumar
2015-01-01
The goal of the NASA Advanced Space Power Systems Project is to develop advanced, game changing technologies that will provide future NASA space exploration missions with safe, reliable, light weight and compact power generation and energy storage systems. The development effort is focused on maturing the technologies from a technology readiness level of approximately 23 to approximately 56 as defined in the NASA Procedural Requirement 7123.1B. Currently, the project is working on two critical technology areas: High specific energy batteries, and regenerative fuel cell systems with passive fluid management. Examples of target applications for these technologies are: extending the duration of extravehicular activities (EVA) with high specific energy and energy density batteries; providing reliable, long-life power for rovers with passive fuel cell and regenerative fuel cell systems that enable reduced system complexity. Recent results from the high energy battery and regenerative fuel cell technology development efforts will be presented. The technical approach, the key performance parameters and the technical results achieved to date in each of these new elements will be included. The Advanced Space Power Systems Project is part of the Game Changing Development Program under NASAs Space Technology Mission Directorate.
NASA Astrophysics Data System (ADS)
Yu, Yongtao; Li, Jonathan; Wen, Chenglu; Guan, Haiyan; Luo, Huan; Wang, Cheng
2016-03-01
This paper presents a novel algorithm for detection and recognition of traffic signs in mobile laser scanning (MLS) data for intelligent transportation-related applications. The traffic sign detection task is accomplished based on 3-D point clouds by using bag-of-visual-phrases representations; whereas the recognition task is achieved based on 2-D images by using a Gaussian-Bernoulli deep Boltzmann machine-based hierarchical classifier. To exploit high-order feature encodings of feature regions, a deep Boltzmann machine-based feature encoder is constructed. For detecting traffic signs in 3-D point clouds, the proposed algorithm achieves an average recall, precision, quality, and F-score of 0.956, 0.946, 0.907, and 0.951, respectively, on the four selected MLS datasets. For on-image traffic sign recognition, a recognition accuracy of 97.54% is achieved by using the proposed hierarchical classifier. Comparative studies with the existing traffic sign detection and recognition methods demonstrate that our algorithm obtains promising, reliable, and high performance in both detecting traffic signs in 3-D point clouds and recognizing traffic signs on 2-D images.
Aschbrenner, Kelly; Bartels, Stephen; Mueser, Kim; Carpenter-Song, Elizabeth; Kinney, Allison
2012-11-01
This focus group study explored the potential benefits and challenges of involving family members and significant others in a healthy lifestyle program for people with serious mental illness (SMI). Six focus group interviews were conducted with a total of 30 people with SMI, who were participants in a healthy lifestyle intervention. Separate focus groups were conducted for high and low achievers in the program based on clinically significant weight loss or significant increase in fitness. Thematic analysis revealed that social support for diet and exercise was a perceived benefit to involving others in a healthy lifestyle program. Other perceived benefits were the potential to increase others' understanding of the challenges of living with mental illness and to enhance the quality of relationships. Participants identified practical and logistical concerns that could interfere with participation, including partner reliability and desirability, scheduling, and lack of financial resources. Participants in the high achiever group expressed a greater desire to involve others in exercise than did participants in the low achiever group. Programs aimed at helping people with SMI make lifestyle changes may increase their effectiveness by involving significant others. Mobilizing social support networks for health behavior change is an ideal role for social workers.
Xu, Ziwei; Qiu, Lu; Ding, Feng
2018-03-21
Depending on its specific structure, or so-called chirality, a single-walled carbon nanotube (SWCNT) can be either a conductor or a semiconductor. This feature ensures great potential for building ∼1 nm sized electronics if chirality-selected SWCNTs could be achieved. However, due to the limited understanding of the growth mechanism of SWCNTs, reliable methods for chirality-selected SWCNTs are still pending. Here we present a theoretical model on the chirality assignment and control of SWCNTs during the catalytic growth. This study reveals that the chirality of a SWCNT is determined by the kinetic incorporation of pentagons, especially the last (6 th ) one, during the nucleation stage. Our analysis showed that the chirality of a SWCNT is randomly assigned on a liquid or liquid-like catalyst surface, and two routes of synthesizing chirality-selected SWCNTs, which are verified by recent experimental achievements, are demonstrated. They are (i) by using high melting point crystalline catalysts, such as Ta, W, Re, Os, or their alloys, and (ii) by frequently changing the chirality of SWCNTs during their growth. This study paves the way for achieving chirality-selective SWCNT growth for high performance SWCNT based electronics.
Epistemological Beliefs and Academic Achievement
ERIC Educational Resources Information Center
Arslantas, Halis Adnan
2016-01-01
This study aimed to identify the relationship between teacher candidates' epistemological beliefs and academic achievement. The participants of the study were 353 teacher candidates studying their fourth year at the Education Faculty. The Epistemological Belief Scale was used which adapted to Turkish through reliability and validity work by…
Brayton heat exchange unit development program
NASA Technical Reports Server (NTRS)
Morse, C. J.; Richard, C. E.; Duncan, J. D.
1971-01-01
A Brayton Heat Exchanger Unit (BHXU), consisting of a recuperator, a heat sink heat exchanger and a gas ducting system, was designed, fabricated, and tested. The design was formulated to provide a high performance unit suitable for use in a long-life Brayton-cycle powerplant. A parametric analysis and design study was performed to establish the optimum component configurations to achieve low weight and size and high reliability, while meeting the requirements of high effectiveness and low pressure drop. Layout studies and detailed mechanical and structural design were performed to obtain a flight-type packaging arrangement. Evaluation testing was conducted from which it is estimated that near-design performance can be expected with the use of He-Xe as the working fluid.
Heat pipe radiator technology for space power systems
NASA Technical Reports Server (NTRS)
Carlson, A. W.; Gustafson, E.; Ercegovic, B. A.
1986-01-01
High-reliability high-performance deployable monogroove and dual-slot heat pipe radiator systems to meet the requirements for electric power in future space missions, such as the 300-kW(e) electric powder demand projected for NASA's Space Station, are discussed. Analytical model trade studies of various configurations show the advantages of the dual-slot heat pipe radiator for high temperature applications as well as its weight reduction potential over the 50-350 F temperature range. The ammonia-aluminum monogroove heat pipe, limited to below-180 F operating temperatures, is under development, and can employ methanol-stainless steel heat pipes to achieve operating temperatures in excess of 300 F. Dual-slot heat pipe configuration proof-of-concept testing was begun in 1985.
Novel high-density packaging of solid state diode pumped eye-safe laser for LIBS
NASA Astrophysics Data System (ADS)
Bares, Kim; Torgerson, Justin; McNeil, Laine; Maine, Patrick; Patterson, Steve
2018-02-01
Laser-Induced Breakdown Spectroscopy (LIBS) has proven to be a useful research tool for material analysis for decades. However, because of the amount of energy required in a few nanosecond pulse to generate a stable and reliable LIBS signal, the lasers are often large and inefficient, relegating their implementation to research facilities, factory floors, and assembly lines. Small portable LIBS systems are now possible without having to compromise on energy needs by leveraging off of advances in high-density packaging of electronics, opto-mechanics, and highly efficient laser resonator architecture. This paper explores the integration of these techniques to achieve a mJ class eye-safe LIBS laser source, while retaining a small, light-weight package suitable for handheld systems.
Highly Transparent and Conductive Metallized Nanofibers by Electrospinning and Electroplating
NASA Astrophysics Data System (ADS)
Yoon, Sam S.; Yarin, Alexander L.
2017-11-01
Transparent conducting films (TCFs) and transparent heaters (THs) are of interest for a wide variety of applications, from displays to window defrosters. Here, we demonstrate production of highly flexible, conducting, and transparent copper (Cu), nickel (Ni), platinum (Pt), and silver (Ag) nanofibers suitable for use not only in TCFs and THs but also in some other engineering applications. The merging of fibers at their intersections (i.e. self-junctioning) minimizes contact resistance in these films. These metallized nanofibers exhibited a remarkably low sheet resistance at a high optical transmittance. This low sheet resistance allows them to serve as low-voltage heaters, achieving a high heating temperature at a relatively low applied voltage. These nanofibers are free-standing, flexible, stretchable, and their mechanical reliability was confirmed through various mechanical endurance tests.
Least reliable bits coding (LRBC) for high data rate satellite communications
NASA Technical Reports Server (NTRS)
Vanderaar, Mark; Budinger, James; Wagner, Paul
1992-01-01
LRBC, a bandwidth efficient multilevel/multistage block-coded modulation technique, is analyzed. LRBC uses simple multilevel component codes that provide increased error protection on increasingly unreliable modulated bits in order to maintain an overall high code rate that increases spectral efficiency. Soft-decision multistage decoding is used to make decisions on unprotected bits through corrections made on more protected bits. Analytical expressions and tight performance bounds are used to show that LRBC can achieve increased spectral efficiency and maintain equivalent or better power efficiency compared to that of BPSK. The relative simplicity of Galois field algebra vs the Viterbi algorithm and the availability of high-speed commercial VLSI for block codes indicates that LRBC using block codes is a desirable method for high data rate implementations.
INFLUENCES OF RESPONSE RATE AND DISTRIBUTION ON THE CALCULATION OF INTEROBSERVER RELIABILITY SCORES
Rolider, Natalie U.; Iwata, Brian A.; Bullock, Christopher E.
2012-01-01
We examined the effects of several variations in response rate on the calculation of total, interval, exact-agreement, and proportional reliability indices. Trained observers recorded computer-generated data that appeared on a computer screen. In Study 1, target responses occurred at low, moderate, and high rates during separate sessions so that reliability results based on the four calculations could be compared across a range of values. Total reliability was uniformly high, interval reliability was spuriously high for high-rate responding, proportional reliability was somewhat lower for high-rate responding, and exact-agreement reliability was the lowest of the measures, especially for high-rate responding. In Study 2, we examined the separate effects of response rate per se, bursting, and end-of-interval responding. Response rate and bursting had little effect on reliability scores; however, the distribution of some responses at the end of intervals decreased interval reliability somewhat, proportional reliability noticeably, and exact-agreement reliability markedly. PMID:23322930
NASA Astrophysics Data System (ADS)
Zhao, W. N.; Yang, X. J.; Yao, C.; Ma, D. G.; Tang, H. J.
2017-10-01
Inductive power transfer (IPT) is a practical and preferable method for wireless electric vehicle (EV) charging which proved to be safe, convenient and reliable. Due to the air gap between the magnetic coupler, the magnetic field coupling decreases and the magnetic leakage increases significantly compared to traditional transformer, and this may lead to the magnetic flux density around the coupler more than the safety limit for human. So magnetic shielding should be adding to the winding made from litz wire to enhance the magnetic field coupling effect in the working area and reduce magnetic field strength in non-working area. Magnetic shielding can be achieved by adding high-permeability material or high-conductivity material. For high-permeability material its magnetic reluctance is much lower than the surrounding air medium so most of the magnetic line goes through the high-permeability material rather than surrounding air. For high-conductivity material the eddy current in the material can produce reverse magnetic field to achieve magnetic shielding. This paper studies the effect of the two types of shielding material on coupler for wireless EV charging and designs combination shielding made from high-permeability material and high-conductivity material. The investigation of the paper is done with the help of finite element analysis.
The feasibility of sharing simulation-based evaluation scenarios in anesthesiology.
Berkenstadt, Haim; Kantor, Gareth S; Yusim, Yakov; Gafni, Naomi; Perel, Azriel; Ezri, Tiberiu; Ziv, Amitai
2005-10-01
We prospectively assessed the feasibility of international sharing of simulation-based evaluation tools despite differences in language, education, and anesthesia practice, in an Israeli study, using validated scenarios from a multi-institutional United States (US) study. Thirty-one Israeli junior anesthesia residents performed four simulation scenarios. Training sessions were videotaped and performance was assessed using two validated scoring systems (Long and Short Forms) by two independent raters. Subjects scored from 37 to 95 (70 +/- 12) of 108 possible points with the "Long Form" and "Short Form" scores ranging from 18 to 35 (28.2 +/- 4.5) of 40 possible points. Scores >70% of the maximal score were achieved by 61% of participants in comparison to only 5% in the original US study. The scenarios were rated as very realistic by 80% of the participants (grade 4 on a 1-4 scale). Reliability of the original assessment tools was demonstrated by internal consistencies of 0.66 for the Long and 0.75 for the Short Form (Cronbach alpha statistic). Values in the original study were 0.72-0.76 for the Long and 0.71-0.75 for the Short Form. The reliability did not change when a revised Israeli version of the scoring was used. Interrater reliability measured by Pearson correlation was 0.91 for the Long and 0.96 for the Short Form (P < 0.01). The high scores for plausibility given to the scenarios and the similar reliability of the original assessment tool support the feasibility of using simulation-based evaluation tools, developed in the US, in Israel. The higher scores achieved by Israeli residents may be related to the fact that most Israeli residents are immigrants with previous training in anesthesia. Simulation-based assessment tools developed in a multi-institutional study in the United States can be used in Israel despite the differences in language, education, and medical system.
NASA Astrophysics Data System (ADS)
Kemper, Björn; Lenz, Philipp; Bettenworth, Dominik; Krausewitz, Philipp; Domagk, Dirk; Ketelhut, Steffi
2015-05-01
Digital holographic microscopy (DHM) has been demonstrated to be a versatile tool for high resolution non-destructive quantitative phase imaging of surfaces and multi-modal minimally-invasive monitoring of living cell cultures in-vitro. DHM provides quantitative monitoring of physiological processes through functional imaging and structural analysis which, for example, gives new insight into signalling of cellular water permeability and cell morphology changes due to toxins and infections. Also the analysis of dissected tissues quantitative DHM phase contrast prospects application fields by stain-free imaging and the quantification of tissue density changes. We show that DHM allows imaging of different tissue layers with high contrast in unstained tissue sections. As the investigation of fixed samples represents a very important application field in pathology, we also analyzed the influence of the sample preparation. The retrieved data demonstrate that the quality of quantitative DHM phase images of dissected tissues depends strongly on the fixing method and common staining agents. As in DHM the reconstruction is performed numerically, multi-focus imaging is achieved from a single digital hologram. Thus, we evaluated the automated refocussing feature of DHM for application on different types of dissected tissues and revealed that on moderately stained samples highly reproducible holographic autofocussing can be achieved. Finally, it is demonstrated that alterations of the spatial refractive index distribution in murine and human tissue samples represent a reliable absolute parameter that is related of different degrees of inflammation in experimental colitis and Crohn's disease. This paves the way towards the usage of DHM in digital pathology for automated histological examinations and further studies to elucidate the translational potential of quantitative phase microscopy for the clinical management of patients, e.g., with inflammatory bowel disease.
Integration of multiple biological features yields high confidence human protein interactome.
Karagoz, Kubra; Sevimoglu, Tuba; Arga, Kazim Yalcin
2016-08-21
The biological function of a protein is usually determined by its physical interaction with other proteins. Protein-protein interactions (PPIs) are identified through various experimental methods and are stored in curated databases. The noisiness of the existing PPI data is evident, and it is essential that a more reliable data is generated. Furthermore, the selection of a set of PPIs at different confidence levels might be necessary for many studies. Although different methodologies were introduced to evaluate the confidence scores for binary interactions, a highly reliable, almost complete PPI network of Homo sapiens is not proposed yet. The quality and coverage of human protein interactome need to be improved to be used in various disciplines, especially in biomedicine. In the present work, we propose an unsupervised statistical approach to assign confidence scores to PPIs of H. sapiens. To achieve this goal PPI data from six different databases were collected and a total of 295,288 non-redundant interactions between 15,950 proteins were acquired. The present scoring system included the context information that was assigned to PPIs derived from eight biological attributes. A high confidence network, which included 147,923 binary interactions between 13,213 proteins, had scores greater than the cutoff value of 0.80, for which sensitivity, specificity, and coverage were 94.5%, 80.9%, and 82.8%, respectively. We compared the present scoring method with others for evaluation. Reducing the noise inherent in experimental PPIs via our scoring scheme increased the accuracy significantly. As it was demonstrated through the assessment of process and cancer subnetworks, this study allows researchers to construct and analyze context-specific networks via valid PPI sets and one can easily achieve subnetworks around proteins of interest at a specified confidence level. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duan, Wentao; Vemuri, Rama S.; Hu, Dehong
Redox flow batteries have been considered as one of the most promising stationary energy storage solutions for improving the reliability of the power grid and deployment of renewable energy technologies. Among the many flow battery chemistries, nonaqueous flow batteries have the potential to achieve high energy density because of the broad voltage windows of nonaqueous electrolytes. However, significant technical hurdles exist currently limiting nonaqueous flow batteries to demonstrate their full potential, such as low redox concentrations, low operating currents, under-explored battery status monitoring, etc. In an attempt to address these limitations, we report a nonaqueous flow battery based on amore » highly soluble, redox-active organic nitronyl nitroxide radical compound, 2-phenyl-4,4,5,5-tetramethylimidazoline-1-oxyl-3-oxide (PTIO). This redox materials exhibits an ambipolar electrochemical property with two reversible redox pairs that are moderately separated by a voltage gap of ~1.7 V. Therefore, PTIO can serve as both anolyte and catholyte redox materials to form a symmetric flow battery chemistry, which affords the advantages such as high effective redox concentrations and low irreversible redox material crossover. The PTIO flow battery shows decent electrochemical cyclability under cyclic voltammetry and flow cell conditions; an improved redox concentration of 0.5 M PTIO and operational current density of 20 mA cm-2 were achieved in flow cell tests. Moreover, we show that Fourier transform infrared (FTIR) spectroscopy could measure the PTIO concentrations during the PTIO flow battery cycling and offer reasonably accurate detection of the battery state of charge (SOC) as cross-validated by electron spin resonance measurements. This study suggests FTIR can be used as a reliable online SOC sensor to monitor flow battery status and ensure battery operations stringently in a safe SOC range.« less
Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.
2017-01-01
Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control group for both instruments. Conclusions: Results suggest that the intervention influenced how girls responded to indicator items. Neither of the instruments achieved simultaneous metric invariance making it difficult to assess mean differences in PA self-efficacy between groups. PMID:28824487
Development and validation of a Malawian version of the primary care assessment tool.
Dullie, Luckson; Meland, Eivind; Hetlevik, Øystein; Mildestvedt, Thomas; Gjesdal, Sturla
2018-05-16
Malawi does not have validated tools for assessing primary care performance from patients' experience. The aim of this study was to develop a Malawian version of Primary Care Assessment Tool (PCAT-Mw) and to evaluate its reliability and validity in the assessment of the core primary care dimensions from adult patients' perspective in Malawi. A team of experts assessed the South African version of the primary care assessment tool (ZA-PCAT) for face and content validity. The adapted questionnaire underwent forward and backward translation and a pilot study. The tool was then used in an interviewer administered cross-sectional survey in Neno district, Malawi, to test validity and reliability. Exploratory factor analysis was performed on a random half of the sample to evaluate internal consistency, reliability and construct validity of items and scales. The identified constructs were then tested with confirmatory factor analysis. Likert scale assumption testing and descriptive statistics were done on the final factor structure. The PCAT-Mw was further tested for intra-rater and inter-rater reliability. From the responses of 631 patients, a 29-item PCAT-Mw was constructed comprising seven multi-item scales, representing five primary care dimensions (first contact, continuity, comprehensiveness, coordination and community orientation). All the seven scales achieved good internal consistency, item-total correlations and construct validity. Cronbach's alpha coefficient ranged from 0.66 to 0.91. A satisfactory goodness of fit model was achieved (GFI = 0.90, CFI = 0.91, RMSEA = 0.05, PCLOSE = 0.65). The full range of possible scores was observed for all scales. Scaling assumptions tests were achieved for all except the two comprehensiveness scales. Intra-class correlation coefficient (ICC) was 0.90 (n = 44, 95% CI 0.81-0.94, p < 0.001) for intra-rater reliability and 0.84 (n = 42, 95% CI 0.71-0.96, p < 0.001) for inter-rater reliability. Comprehensive metric analyses supported the reliability and validity of PCAT-Mw in assessing the core concepts of primary care from adult patients' experience. This tool could be used for health service research in primary care in Malawi.
Intelligent Engine Systems: Thermal Management and Advanced Cooling
NASA Technical Reports Server (NTRS)
Bergholz, Robert
2008-01-01
The objective is to provide turbine-cooling technologies to meet Propulsion 21 goals related to engine fuel burn, emissions, safety, and reliability. Specifically, the GE Aviation (GEA) Advanced Turbine Cooling and Thermal Management program seeks to develop advanced cooling and flow distribution methods for HP turbines, while achieving a substantial reduction in total cooling flow and assuring acceptable turbine component safety and reliability. Enhanced cooling techniques, such as fluidic devices, controlled-vortex cooling, and directed impingement jets, offer the opportunity to incorporate both active and passive schemes. Coolant heat transfer enhancement also can be achieved from advanced designs that incorporate multi-disciplinary optimization of external film and internal cooling passage geometry.
Rapid Prototyping of Slot Die Devices for Roll to Roll Production of EL Fibers
Bellingham, Alyssa; Bromhead, Nicholas; Fontecchio, Adam
2017-01-01
There is a growing interest in fibers supporting optoelectrical properties for textile and wearable display applications. Solution-processed electroluminescent (EL) material systems can be continuously deposited onto fiber or yarn substrates in a roll-to-roll process, making it easy to scale manufacturing. It is important to have precise control over layer deposition to achieve uniform and reliable light emission from these EL fibers. Slot-die coating offers this control and increases the rate of EL fiber production. Here, we report a highly adaptable, cost-effective 3D printing model for developing slot dies used in automatic coating systems. The resulting slot-die coating system enables rapid, reliable production of alternating current powder-based EL (ACPEL) fibers and can be adapted for many material systems. The benefits of this system over dip-coating for roll-to-roll production of EL fibers are demonstrated in this work. PMID:28772954
TROTER's (Tiny Robotic Operation Team Experiment): A new concept of space robots
NASA Technical Reports Server (NTRS)
Su, Renjeng
1990-01-01
In view of the future need of automation and robotics in space and the existing approaches to the problem, we proposed a new concept of robots for space construction. The new concept is based on the basic idea of decentralization. Decentralization occurs, on the one hand, in using teams of many cooperative robots for construction tasks. Redundancy and modular design are explored to achieve high reliability for team robotic operations. Reliability requirement on individual robots is greatly reduced. Another area of decentralization is manifested by the proposed control hierarchy which eventually includes humans in the loop. The control strategy is constrained by various time delays and calls for different levels of abstraction of the task dynamics. Such technology is needed for remote control of robots in an uncertain environment. Thus, concerns of human safety around robots are relaxed. This presentation also introduces the required technologies behind the new robotic concept.
Photonic elements in smart systems for use in aerospace platforms
NASA Astrophysics Data System (ADS)
Adamovsky, Grigory; Baumbick, Robert J.; Tabib-Azar, Massood
1998-07-01
To compete globally in the next millennium, designers of new transportation vehicles will have to be innovative. Keen competition will reward innovative concepts that are developed and proven first. In order to improve reliability of aerospace platforms and reduce operating cots, new technologies must be exploited to produce autonomous systems, based on highly distributed, smart systems, which can be treated as line replaceable units. These technologies include photonics, which provide sensing and information transfer functions, and micro electro mechanical systems that will produce the actuation and, in some cases, may even provide a computing capability that resembles the hydro- mechanical control system used in older aircraft systems. The combination of these technologies will provide unique systems that will enable achieving the reliability and cost goals dictated by global market. In the article we review some of these issues and discuss a role of photonics in smart system for aerospace platforms.
Rapid Prototyping of Slot Die Devices for Roll to Roll Production of EL Fibers.
Bellingham, Alyssa; Bromhead, Nicholas; Fontecchio, Adam
2017-05-29
There is a growing interest in fibers supporting optoelectrical properties for textile and wearable display applications. Solution-processed electroluminescent (EL) material systems can be continuously deposited onto fiber or yarn substrates in a roll-to-roll process, making it easy to scale manufacturing. It is important to have precise control over layer deposition to achieve uniform and reliable light emission from these EL fibers. Slot-die coating offers this control and increases the rate of EL fiber production. Here, we report a highly adaptable, cost-effective 3D printing model for developing slot dies used in automatic coating systems. The resulting slot-die coating system enables rapid, reliable production of alternating current powder-based EL (ACPEL) fibers and can be adapted for many material systems. The benefits of this system over dip-coating for roll-to-roll production of EL fibers are demonstrated in this work.
Dynamic laser piercing of thick section metals
NASA Astrophysics Data System (ADS)
Pocorni, Jetro; Powell, John; Frostevarg, Jan; Kaplan, Alexander F. H.
2018-01-01
Before a contour can be laser cut the laser first needs to pierce the material. The time taken to achieve piercing should be minimised to optimise productivity. One important aspect of laser piercing is the reliability of the process because industrial laser cutting machines are programmed for the minimum reliable pierce time. In this work piercing experiments were carried out in 15 mm thick stainless steel sheets, comparing a stationary laser and a laser which moves along a circular trajectory with varying processing speeds. Results show that circular piercing can decrease the pierce duration by almost half compared to stationary piercing. High speed imaging (HSI) was employed during the piercing process to understand melt behaviour inside the pierce hole. HSI videos show that circular rotation of the laser beam forces melt to eject in opposite direction of the beam movement, while in stationary piercing the melt ejects less efficiently in random directions out of the hole.
BDS/GPS Dual Systems Positioning Based on the Modified SR-UKF Algorithm
Kong, JaeHyok; Mao, Xuchu; Li, Shaoyuan
2016-01-01
The Global Navigation Satellite System can provide all-day three-dimensional position and speed information. Currently, only using the single navigation system cannot satisfy the requirements of the system’s reliability and integrity. In order to improve the reliability and stability of the satellite navigation system, the positioning method by BDS and GPS navigation system is presented, the measurement model and the state model are described. Furthermore, the modified square-root Unscented Kalman Filter (SR-UKF) algorithm is employed in BDS and GPS conditions, and analysis of single system/multi-system positioning has been carried out, respectively. The experimental results are compared with the traditional estimation results, which show that the proposed method can perform highly-precise positioning. Especially when the number of satellites is not adequate enough, the proposed method combine BDS and GPS systems to achieve a higher positioning precision. PMID:27153068
Kandhro, Aftab A; Laghari, Abdul Hafeez; Mahesar, Sarfaraz A; Saleem, Rubina; Nelofar, Aisha; Khan, Salman Tariq; Sherazi, S T H
2013-11-01
A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product. Copyright © 2013 Elsevier B.V. All rights reserved.
Ultra precision and reliable bonding method
NASA Technical Reports Server (NTRS)
Gwo, Dz-Hung (Inventor)
2001-01-01
The bonding of two materials through hydroxide-catalyzed hydration/dehydration is achieved at room temperature by applying hydroxide ions to at least one of the two bonding surfaces and by placing the surfaces sufficiently close to each other to form a chemical bond between them. The surfaces may be placed sufficiently close to each other by simply placing one surface on top of the other. A silicate material may also be used as a filling material to help fill gaps between the surfaces caused by surface figure mismatches. A powder of a silica-based or silica-containing material may also be used as an additional filling material. The hydroxide-catalyzed bonding method forms bonds which are not only as precise and transparent as optical contact bonds, but also as strong and reliable as high-temperature frit bonds. The hydroxide-catalyzed bonding method is also simple and inexpensive.
Myneni, Sahiti; Cobb, Nathan K; Cohen, Trevor
2016-01-01
Analysis of user interactions in online communities could improve our understanding of health-related behaviors and inform the design of technological solutions that support behavior change. However, to achieve this we would need methods that provide granular perspective, yet are scalable. In this paper, we present a methodology for high-throughput semantic and network analysis of large social media datasets, combining semi-automated text categorization with social network analytics. We apply this method to derive content-specific network visualizations of 16,492 user interactions in an online community for smoking cessation. Performance of the categorization system was reasonable (average F-measure of 0.74, with system-rater reliability approaching rater-rater reliability). The resulting semantically specific network analysis of user interactions reveals content- and behavior-specific network topologies. Implications for socio-behavioral health and wellness platforms are also discussed.
JPARSS: A Java Parallel Network Package for Grid Computing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Jie; Akers, Walter; Chen, Ying
2002-03-01
The emergence of high speed wide area networks makes grid computinga reality. However grid applications that need reliable data transfer still have difficulties to achieve optimal TCP performance due to network tuning of TCP window size to improve bandwidth and to reduce latency on a high speed wide area network. This paper presents a Java package called JPARSS (Java Parallel Secure Stream (Socket)) that divides data into partitions that are sent over several parallel Java streams simultaneously and allows Java or Web applications to achieve optimal TCP performance in a grid environment without the necessity of tuning TCP window size.more » This package enables single sign-on, certificate delegation and secure or plain-text data transfer using several security components based on X.509 certificate and SSL. Several experiments will be presented to show that using Java parallelstreams is more effective than tuning TCP window size. In addition a simple architecture using Web services« less
Progress in Development of a Miniature Pulse Tube Cooler for Space Applications
NASA Astrophysics Data System (ADS)
Gibson, A. S.; Hunt, R.; Charles, I.; Duband, L.; Crook, M. R.; Orlowska, A. H.; Bradshaw, T. W.; Linder, M.
2004-06-01
A pulse tube cryocooler is under development for high-reliability spacecraft applications. Recent developments in the assembly and verification of a Miniature Pulse Tube Cooler (MPTC) are presented, including the latest data from the test program. Details of advances related to the compressor, pulse tube and electronics are discussed. The pulse tube cooler achieves high efficiency, optimised through an extensive process of breadboard testing and analysis and is now approaching a more mature Engineering Model (EM) status. A representative pulse tube cold finger has been verified with respect to design changes incorporated following the breadboard test phase. Mass, heat lift and parasitic losses have been improved. A mechanical system mass of 3.1 kg has been achieved. Cold finger tests have demonstrated the ability of the pulse tube to lift 1.5 W at 80 K and to reach <50 K for a PV-work of 25 W. The useful range of operation for the cooler extends below 60 K, where test results indicate 600 mW of heat lift capability.
Stabilization Approaches for Linear and Nonlinear Reduced Order Models
NASA Astrophysics Data System (ADS)
Rezaian, Elnaz; Wei, Mingjun
2017-11-01
It has been a major concern to establish reduced order models (ROMs) as reliable representatives of the dynamics inherent in high fidelity simulations, while fast computation is achieved. In practice it comes to stability and accuracy of ROMs. Given the inviscid nature of Euler equations it becomes more challenging to achieve stability, especially where moving discontinuities exist. Originally unstable linear and nonlinear ROMs are stabilized here by two approaches. First, a hybrid method is developed by integrating two different stabilization algorithms. At the same time, symmetry inner product is introduced in the generation of ROMs for its known robust behavior for compressible flows. Results have shown a notable improvement in computational efficiency and robustness compared to similar approaches. Second, a new stabilization algorithm is developed specifically for nonlinear ROMs. This method adopts Particle Swarm Optimization to enforce a bounded ROM response for minimum discrepancy between the high fidelity simulation and the ROM outputs. Promising results are obtained in its application on the nonlinear ROM of an inviscid fluid flow with discontinuities. Supported by ARL.
Feasibility model of a high reliability five-year tape transport, volume 2
NASA Technical Reports Server (NTRS)
Eshleman, R. L.; Meyers, A. P.; Davidson, W. A.; Gortowski, R. C.; Anderson, M. E.
1973-01-01
Analysis of the design features of the modularized tape transport renders a life expectancy in excess of five years. Tests performed on the tape transport were directed toward determining its performance capability. These tests revealed that the tape jitter and skew are in the range achieved by high quality digital tape transports. Guidance of the tape in the lateral sense by the use of the two hybrid crowned rollers proved to be excellent. Tracking was maintained within less than one thousandth inch (approximately 2 micrometers). The guidance capability demonstrated makes possible the achievement of the performance objective of 7.2 x 10 to the 9th power storage capability employing 1500 ft. of one inch wide tape with a packing density of 5,000 bits per inch per track on 80 tracks. Also, the machine showed excellent characteristics operating over a wide range of tape speeds. The basic design concept lends itself to growth and adaptation to a wide range of recorder requirements.
NASA Astrophysics Data System (ADS)
Wolff, Andrzej
2010-01-01
The temperature of a brake friction surface influences significantly the braking effectiveness. The paper describes a heat transfer process in car brakes. Using a developed program of finite element method, the temperature distributions in brake rotors (disc and drum brake) of a light truck have been calculated. As a preliminary consistency criterion of the brake thermal state in road and roll-stand braking conditions, a balance of the energy cumulated in the brake rotor has been taken into account. As the most reliable consistency criterion an equality of average temperatures of the friction surface has been assumed. The presented method allows to achieve on a roll-stand the analogical thermal states of automotive brakes, which are observed during braking in road conditions. Basing on this method, it is possible to calculate the braking time and force for a high-speed roll-stand. In contrast to the previous papers of the author, new calculation results have been presented.
Towards stable and commercially available perovskite solar cells
Park, Nam-Gyu; Grätzel, Michael; Miyasaka, Tsutomu; ...
2016-10-17
Solar cells employing a halide perovskite with an organic cation now show power conversion efficiency of up to 22%. But, these cells are facing issues towards commercialization, such as the need to achieve long-term stability and the development of a manufacturing method for the reproducible fabrication of high-performance devices. We propose a strategy to obtain stable and commercially viable perovskite solar cells. A reproducible manufacturing method is suggested, as well as routes to manage grain boundaries and interfacial charge transport. Electroluminescence is regarded as a metric to gauge theoretical efficiency. We highlight how optimizing the design of device architectures ismore » important not only for achieving high efficiency but also for hysteresis-free and stable performance. Here, we argue that reliable device characterization is needed to ensure the advance of this technology towards practical applications. We believe that perovskite-based devices can be competitive with silicon solar modules, and discuss issues related to the safe management of toxic material.« less
A CO trace gas detection system based on continuous wave DFB-QCL
NASA Astrophysics Data System (ADS)
Dang, Jingmin; Yu, Haiye; Sun, Yujing; Wang, Yiding
2017-05-01
A compact and mobile system was demonstrated for the detection of carbon monoxide (CO) at trace level. This system adopted a high-power, continuous wave (CW), distributed feedback quantum cascade laser (DFB-QCL) operating at ∼22 °C as excitation source. Wavelength modulation spectroscopy (WMS) as well as second harmonic detection was used to isolate complex, overlapping spectral absorption features typical of ambient pressures and to achieve excellent specificity and high detection sensitivity. For the selected P(11) absorption line of CO molecule, located at 2099.083 cm-1, a limit of detection (LoD) of 26 ppb by volume (ppbv) at atmospheric pressure was achieved with a 1 s acquisition time. Allan deviation analysis was performed to investigate the long term performance of the CO detection system, and a measurement precision of 3.4 ppbv was observed with an optimal integration time of approximate 114 s, which verified the reliable and robust operation of the developed system.
Fiber-optic microsphere-based arrays for multiplexed biological warfare agent detection.
Song, Linan; Ahn, Soohyoun; Walt, David R
2006-02-15
We report a multiplexed high-density DNA array capable of rapid, sensitive, and reliable identification of potential biological warfare agents. An optical fiber bundle containing 6000 individual 3.1-mum-diameter fibers was chemically etched to yield microwells and used as the substrate for the array. Eighteen different 50-mer single-stranded DNA probes were covalently attached to 3.1-mum microspheres. Probe sequences were designed for Bacillus anthracis, Yersinia pestis, Francisella tularensis, Brucella melitensis, Clostridium botulinum, Vaccinia virus, and one biological warfare agent (BWA) simulant, Bacillus thuringiensis kurstaki. The microspheres were distributed into the microwells to form a randomized multiplexed high-density DNA array. A detection limit of 10 fM in a 50-microL sample volume was achieved within 30 min of hybridization for B. anthracis, Y. pestis, Vaccinia virus, and B. thuringiensis kurstaki. We used both specific responses of probes upon hybridization to complementary targets as well as response patterns of the multiplexed array to identify BWAs with high accuracy. We demonstrated the application of this multiplexed high-density DNA array for parallel identification of target BWAs in spiked sewage samples after PCR amplification. The array's miniaturized feature size, fabrication flexibility, reusability, and high reproducibility may enable this array platform to be integrated into a highly sensitive, specific, and reliable portable instrument for in situ BWA detection.
Visual Inspection Reliability for Precision Manufactured Parts.
See, Judi E
2015-12-01
Sandia National Laboratories conducted an experiment for the National Nuclear Security Administration to determine the reliability of visual inspection of precision manufactured parts used in nuclear weapons. Visual inspection has been extensively researched since the early 20th century; however, the reliability of visual inspection for nuclear weapons parts has not been addressed. In addition, the efficacy of using inspector confidence ratings to guide multiple inspections in an effort to improve overall performance accuracy is unknown. Further, the workload associated with inspection has not been documented, and newer measures of stress have not been applied. Eighty-two inspectors in the U.S. Nuclear Security Enterprise inspected 140 parts for eight different defects. Inspectors correctly rejected 85% of defective items and incorrectly rejected 35% of acceptable parts. Use of a phased inspection approach based on inspector confidence ratings was not an effective or efficient technique to improve the overall accuracy of the process. Results did verify that inspection is a workload-intensive task, dominated by mental demand and effort. Hits for Nuclear Security Enterprise inspection were not vastly superior to the industry average of 80%, and they were achieved at the expense of a high scrap rate not typically observed during visual inspection tasks. This study provides the first empirical data to address the reliability of visual inspection for precision manufactured parts used in nuclear weapons. Results enhance current understanding of the process of visual inspection and can be applied to improve reliability for precision manufactured parts. © 2015, Human Factors and Ergonomics Society.
All-in-One Cellulose Nanocrystals for 3D Printing of Nanocomposite Hydrogels.
Wang, Jieping; Chiappone, Annalisa; Roppolo, Ignazio; Shao, Feng; Fantino, Erika; Lorusso, Massimo; Rentsch, Daniel; Dietliker, Kurt; Pirri, Candido Fabrizio; Grützmacher, Hansjörg
2018-02-23
Cellulose nanocrystals (CNCs) with >2000 photoactive groups on each can act as highly efficient initiators for radical polymerizations, cross-linkers, as well as covalently embedded nanofillers for nanocomposite hydrogels. This is achieved by a simple and reliable method for surface modification of CNCs with a photoactive bis(acyl)phosphane oxide derivative. Shape-persistent and free-standing 3D structured objects were printed with a mono-functional methacrylate, showing a superior swelling capacity and improved mechanical properties. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Study of prototypes of LFoundry active CMOS pixels sensors for the ATLAS detector
NASA Astrophysics Data System (ADS)
Vigani, L.; Bortoletto, D.; Ambroz, L.; Plackett, R.; Hemperek, T.; Rymaszewski, P.; Wang, T.; Krueger, H.; Hirono, T.; Caicedo Sierra, I.; Wermes, N.; Barbero, M.; Bhat, S.; Breugnon, P.; Chen, Z.; Godiot, S.; Pangaud, P.; Rozanov, A.
2018-02-01
Current high energy particle physics experiments at the LHC use hybrid silicon detectors, in both pixel and strip configurations, for their inner trackers. These detectors have proven to be very reliable and performant. Nevertheless, there is great interest in depleted CMOS silicon detectors, which could achieve a similar performance at lower cost of production. We present recent developments of this technology in the framework of the ATLAS CMOS demonstrator project. In particular, studies of two active sensors from LFoundry, CCPD_LF and LFCPIX, are shown.
Li, Pingwei; De Bosscher, Veerle; Pion, Johan; Weissensteiner, Juanita R; Vertonghen, Jikkemien
2018-05-01
Currently in the literature, there is a dearth of empirical research that confirms whether international junior success is a reliable predictor for future international senior success. Despite the uncertainty of the junior-senior relationship, federations and coaches still tend to use junior success as a predictor for long-term senior success. A range of former investigations utilising a retrospective lens has merely focused on success that athletes attained at junior level competitions. Success that was achieved at senior-level competitions but at a junior age was relatively ignored. This study explored to what extent international senior success can be predicted based on success that athletes achieved in either international junior level competitions (i.e. junior medalists) or senior competitions at a junior age (i.e. early achievers). The sample contains 4011 international male and female athletes from three combat sports (taekwondo, wrestling and boxing), who were born between 1974 and 1990 and participated in both international junior and senior-level competitions between 1990 and 2016. Gender and sport differences were compared. The results revealed that 61.4% of the junior medalists and 90.4% of the early achievers went on to win international medals at a senior age. Among the early achievers, 92.2% of the taekwondo athletes, 68.4% of the wrestling athletes and 37.9% of the boxing athletes could be reliably "predicted" to win international senior medals. The findings demonstrate that specific to the three combat sports examined, international junior success appears to be an important predictor to long-term international senior success.
A study on the real-time reliability of on-board equipment of train control system
NASA Astrophysics Data System (ADS)
Zhang, Yong; Li, Shiwei
2018-05-01
Real-time reliability evaluation is conducive to establishing a condition based maintenance system for the purpose of guaranteeing continuous train operation. According to the inherent characteristics of the on-board equipment, the connotation of reliability evaluation of on-board equipment is defined and the evaluation index of real-time reliability is provided in this paper. From the perspective of methodology and practical application, the real-time reliability of the on-board equipment is discussed in detail, and the method of evaluating the realtime reliability of on-board equipment at component level based on Hidden Markov Model (HMM) is proposed. In this method the performance degradation data is used directly to realize the accurate perception of the hidden state transition process of on-board equipment, which can achieve a better description of the real-time reliability of the equipment.
NASA Astrophysics Data System (ADS)
Mishra, Arpit; Ghosh, Parthasarathi
2015-12-01
For low cost, high thrust, space missions with high specific impulse and high reliability, inert weight needs to be minimized and thereby increasing the delivered payload. Turbopump feed system for a liquid propellant rocket engine (LPRE) has the highest power to weight ratio. Turbopumps are primarily equipped with an axial flow inducer to achieve the high angular velocity and low suction pressure in combination with increased system reliability. Performance of the turbopump strongly depends on the performance of the inducer. Thus, for designing a LPRE turbopump, demands optimization of the inducer geometry based on the performance of different off-design operating regimes. In this paper, steady-state CFD analysis of the inducer of a liquid oxygen (LOX) axial pump used as a booster pump for an oxygen rich staged combustion cycle rocket engine has been presented using ANSYS® CFX. Attempts have been made to obtain the performance characteristic curves for the LOX pump inducer. The formalism has been used to predict the performance of the inducer for the throttling range varying from 80% to 113% of nominal thrust and for the different rotational velocities from 4500 to 7500 rpm. The results have been analysed to determine the region of cavitation inception for different inlet pressure.
Medical image digital archive: a comparison of storage technologies
NASA Astrophysics Data System (ADS)
Chunn, Timothy; Hutchings, Matt
1998-07-01
A cost effective, high capacity digital archive system is one of the remaining key factors that will enable a radiology department to eliminate film as an archive medium. The ever increasing amount of digital image data is creating the need for huge archive systems that can reliably store and retrieve millions of images and hold from a few terabytes of data to possibly hundreds of terabytes. Selecting the right archive solution depends on a number of factors: capacity requirements, write and retrieval performance requirements, scaleability in capacity and performance, conformance to open standards, archive availability and reliability, security, cost, achievable benefits and cost savings, investment protection, and more. This paper addresses many of these issues. It compares and positions optical disk and magnetic tape technologies, which are the predominant archive mediums today. New technologies will be discussed, such as DVD and high performance tape. Price and performance comparisons will be made at different archive capacities, plus the effect of file size on random and pre-fetch retrieval time will be analyzed. The concept of automated migration of images from high performance, RAID disk storage devices to high capacity, NearlineR storage devices will be introduced as a viable way to minimize overall storage costs for an archive.
Intra- and inter-rater reliability of digital image analysis for skin color measurement
Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison
2013-01-01
Background We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Methods Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe® Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor® in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Conclusion Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. PMID:23551208
Intra- and inter-rater reliability of digital image analysis for skin color measurement.
Sommers, Marilyn; Beacham, Barbara; Baker, Rachel; Fargo, Jamison
2013-11-01
We determined the intra- and inter-rater reliability of data from digital image color analysis between an expert and novice analyst. Following training, the expert and novice independently analyzed 210 randomly ordered images. Both analysts used Adobe(®) Photoshop lasso or color sampler tools based on the type of image file. After color correction with Pictocolor(®) in camera software, they recorded L*a*b* (L*=light/dark; a*=red/green; b*=yellow/blue) color values for all skin sites. We computed intra-rater and inter-rater agreement within anatomical region, color value (L*, a*, b*), and technique (lasso, color sampler) using a series of one-way intra-class correlation coefficients (ICCs). Results of ICCs for intra-rater agreement showed high levels of internal consistency reliability within each rater for the lasso technique (ICC ≥ 0.99) and somewhat lower, yet acceptable, level of agreement for the color sampler technique (ICC = 0.91 for expert, ICC = 0.81 for novice). Skin L*, skin b*, and labia L* values reached the highest level of agreement (ICC ≥ 0.92) and skin a*, labia b*, and vaginal wall b* were the lowest (ICC ≥ 0.64). Data from novice analysts can achieve high levels of agreement with data from expert analysts with training and the use of a detailed, standard protocol. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Resonator design and performance estimation for a space-based laser transmitter
NASA Astrophysics Data System (ADS)
Agrawal, Lalita; Bhardwaj, Atul; Pal, Suranjan; Kamalakar, J. A.
2006-12-01
Development of a laser transmitter for space applications is a highly challenging task. The laser must be rugged, reliable, lightweight, compact and energy efficient. Most of these features are inherently achieved by diode pumping of solid state lasers. Overall system reliability can further be improved by appropriate optical design of the laser resonator besides selection of suitable electro-optical and opto-mechanical components. This paper presents the design details and the theoretically estimated performance of a crossed-porro prism based, folded Z-shaped laser resonator. A symmetrically pumped Nd: YAG laser rod of 3 mm diameter and 60 mm length is placed in the gain arm with total input peak power of 1800 W from laser diode arrays. Electro-optical Q-switching is achieved through a combination of a polarizer, a fractional waveplate and LiNbO 3 Q-switch crystal (9 x 9 x 25 mm) placed in the feedback arm. Polarization coupled output is obtained by optimizing azimuth angle of quarter wave plate placed in the gain arm. Theoretical estimation of laser output energy and pulse width has been carried out by varying input power levels and resonator length to analyse the performance tolerances. The designed system is capable of meeting the objective of generating laser pulses of 10 ns duration and 30 mJ energy @ 10 Hz.