Wen, Zhaohui; Zhang, Liming; Chen, Chao; Liu, Yibo; Wu, Changjun; Dai, Changsong
2013-04-01
Slow corrosion rate and poor bioactivity restrict iron-based implants in biomedical application. In this study, we design a new iron-foam-based calcium phosphate/chitosan coating biodegradable composites offering a priority mechanical and bioactive property for bone tissue engineering through electrophoretic deposition (EPD) followed by a conversion process into a phosphate buffer solution (PBS). Tensile test results showed that the mechanical property of iron foam could be regulated through altering the construction of polyurethane foam. The priority coatings were deposited from 40% nano hydroxyapatite (nHA)/ethanol suspension mixed with 60% nHA/chitosan-acetic acid aqueous solution. In vitro immersion test showed that oxidation-iron foam as the matrix decreased the amount of iron implanted and had not influence on the bioactivity of this implant, obviously. So, this method could also be a promising method for the preparation of a new calcium phosphate/chitosan coating on foam construction. Copyright © 2012. Published by Elsevier B.V.
Enhancement of L(+)-Lactic Acid Production of Immobilized Rhizopus Oryzae Implanted by Ion Beams
NASA Astrophysics Data System (ADS)
Fan, Yonghong; Yang, Yingge; Zheng, Zhiming; Li, Wen; Wang, Peng; Yao, Liming; Yu, Zengliang
2008-02-01
Immobilized Rhizopus oryzae culturing may be a solution to the inhibited production of L(+)-lactic acid in submerged fermentation, which is caused by aggregated mycelia floc. In the present study, a R. oryzae mutant (RL6041) with a 90% conversion rate of glucose into L-lactic acid was obtained by N+ implantation under the optimized conditions of a beam energy of 15 keV and a dose of 2.6 × 1015 ions/cm2. Using polyurethane foam as the immobilization matrix, the optimal L-lactic acid production conditions were determined as 4 mm polyurethane foam, 150 r/min, 50 g/L ~ 80 g/L of initial glucose, 38°C and pH 6.0. 15-cycle repeated productions of L-lactic acid by immobilized RL6041 were performed under the optimized culturing conditions and over 80% of the glucose was converted into L-lactic acid in 30 hours on average. The results show that immobilized RL6041 is a promising candidate for continuous L-lactic acid production.
NASA Technical Reports Server (NTRS)
Ishaug-Riley, S. L.; Crane, G. M.; Gurlek, A.; Miller, M. J.; Yasko, A. W.; Yaszemski, M. J.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
1997-01-01
Porous biodegradable poly(DL-lactic-co-glycolic acid) foams were seeded with rat marrow stromal cells and implanted into the rat mesentery to investigate in vivo bone formation at an ectopic site. Cells were seeded at a density of 6.83 x 10(5) cells/cm2 onto polymer foams having pore sizes ranging from either 150 to 300 to 710 microns and cultured for 7 days in vitro prior to implantation. The polymer/cell constructs were harvested after 1, 7, 28, or 49 days in vivo and processed for histology and gel permeation chromatography. Visual observation of hematoxylin and eosin-stained sections and von Kossa-stained sections revealed the formation of mineralized bonelike tissue in the constructs within 7 days postimplantation. Ingrowth of vascular tissue was also found adjacent to the islands of bone, supplying the necessary metabolic requirements to the newly formed tissue. Mineralization and bone tissue formation were investigated by histomorphometry. The average penetration depth of mineralized tissue in the construct ranged from 190 +/- 50 microns for foams with 500-710-microns pores to 370 +/- 160 microns for foams with 150-300-microns pores after 49 days in vivo. The mineralized bone volume per surface area and total bone volume per surface area had maximal values of 0.28 +/- 0.21 mm (500-710-microns pore size, day 28) and 0.038 +/- 0.024 mm (150-300-microns, day 28), respectively. As much as 11% of the foam volume penetrated by bone tissue was filled with mineralized tissue. No significant trends over time were observed for any of the measured values (penetration depth, bone volume/surface area, or percent mineralized bone volume). These results suggest the feasibility of bone formation by osteoblast transplantation in an orthotopic site where not only bone formation from transplanted cells but also ingrowth from adjacent bone may occur.
Histological, mechanical, and radiological study of osteoformation in titanium foam implants.
Ito, Kiyoshi; Horiuchi, Tetsuyoshi; Arai, Yoshinori; Kawahara, Ichiro; Hongo, Kazuhiro
2014-11-01
Titanium (Ti) is widely used for implants because of its high mechanical reliability and because it aids osteoformation. However, it also produces artifacts during radiological imaging. Further, Ti implants can sometimes cause the surrounding bone to break. Owing to recent advances, Ti can be transformed into sponge-like, porous materials having a three-dimensional network of pores; such materials are called Ti foams. These foams exhibit distinct characteristics that make them more suitable than nonporous Ti. The objective of this study was to evaluate Ti foams as implant materials. Implants based on Ti foams having porosities of 80% and 90% were embedded in the femurs of 11 rabbits. Implants based on 0% porosity Ti were used as controls. Five rabbits were sacrificed 4 weeks after implantation, while the remaining were sacrificed after 12 weeks. The femurs containing the Ti implants were harvested and analyzed. Biomechanical analyses showed that the 80% porosity implants induced greater osteoformation. There were significant differences in the average pushout strengths of the control and 80% porosity implants after 4 weeks (p = 0.048) and 12 weeks (p = 0.001). Histopathological analyses confirmed osteoformation in the case of the 80% porosity implants. Analyses of the micro-computed tomography images of the Ti foam-based implants did not suggest the presence of artifacts. The 80% porosity Ti implants did not exhibit the shortcomings associated with conventional Ti implants. In addition, they induced greater osteoformation. Finally, the Ti foams did not produce radiological artifacts.
Osseointegration into a Novel Titanium Foam Implant in the Distal Femur of a Rabbit
Willie, Bettina M.; Yang, Xu; Kelly, Natalie H.; Merkow, Justin; Gagne, Shawn; Ware, Robin; Wright, Timothy M.; Bostrom, Mathias P.G.
2010-01-01
A novel porous titanium foam implant has recently been developed to enhance biological fixation of orthopaedic implants to bone. The aim of this study was to examine the mechanical and histological characteristics of bone apposition into two different pore sizes of this titanium foam (565 and 464 micron mean void intercept length) and to compare these characteristics to those obtained with a fully porous conventionally sintered titanium bead implant. Cylindrical implants were studied in a rabbit distal femoral intramedullary osseointegration model at time zero and at 3, 6, and 12 weeks. The amount of bone ingrowth, amount of periprosthetic bone, and mineral apposition rate of periprosthetic bone measured did not differ among the three implant designs at 3, 6, or 12 weeks. By 12 weeks, the interface stiffness and maximum load of the beaded implant was significantly greater than either foam implant. No significant difference was found in the interface stiffness or maximum load between the two foam implant designs at 3, 6, or 12 weeks. The lower compressive modulus of the foam compared to the more dense sintered beaded implants likely contributed to the difference in failure mode. However, the foam implants have a similar compressive modulus to other clinically successful coatings, suggesting they are nonetheless clinically adequate. Additional studies are required to confirm this in weight-bearing models. Histological data suggest that these novel titanium foam implants are a promising alternative to current porous coatings and should be further investigated for clinical application in cementless joint replacement. PMID:20024964
The role of fixation and bone quality on the mechanical stability of tibial knee components.
Lee, R W; Volz, R G; Sheridan, D C
1991-12-01
Tibial component loosening remains one of the major causes of failure of cemented and noncemented total knee arthroplasties. In this study, the authors identified the role of implant design, method of fixation, and bone density as it related to implant stability. The physical properties of "good" and "bad" bone were simulated using a "good" and "bad" foam model of the proximal tibia, fabricated in the laboratory from DARO RF-100 foam. A generic tibial component permitting various fixation designs was implanted into "good" and "bad" variable density foam tibial models in both cemented and noncemented modes. The mechanical stability of the implants was determined using a Materials Testing Machine by the application of an eccentrically applied cyclic load. The micromotion (subsidence and lift-off) of the tibial implants was recorded using two Linear Variable Differential Transformers. Statistically significant differences in implant stability were recorded as a function of fixation method. The most rigid implant fixation was achieved using four peripherally placed, 6.5-mm cancellous screws. The addition of a central stem added stability only in the case of "poor" quality foam. The mechanical stability of noncemented implants related directly to the density of the foam. Implant stability was greatly enhanced in "poor" quality foam by the use of cement. The method of implant fixation and bone density are critical determinants to tibial implant stability.
Wagenführ-Júnior, Jorge; Ribas Filho, Jurandir Marcondes; Nascimento, Marcelo Mazza do; Ribas, Fernanda Marcondes; Wanka, Marcus Vinícius; Godoi, Andressa de Lima
2012-12-01
To evaluate whether polyurethane foam leads more intense foreign-body reaction than silicone foam. To compare the vascularization of the capsules surrounding the foam implants. To investigate if the capsule of polyurethane foam implanted has greater amount of collagen than that of silicone foam. Sixty-four young male Wistar rats were allocated into two groups: polyurethane foam and silicone foam. Subcutaneous discs were implanted into the dorsum of the animals in both groups. The capsules were assessed 28 days, two months, three months and six months postoperatively. Microscopic analysis with H&E stain was performed to evaluate the acute and chronic inflammatory process, foreign-body reaction and neovascularization. The analysis with picrosirius red was performed using the ImageProPlus software, to measure the number of vessels and collagen types I and III. There were no statistical differences between the two groups regarding the acute and chronic inflammatory processes. All rats from the polyurethane group, in all times, exhibited moderate or intense foreign-body reaction, with statistic significant difference (p=0.046) when compared with the silicone group, in which the reaction was either mild or nonexistent at two months. Vascular proliferation was significantly different between the groups at 28 days (p=0.0002), with the polyurethane group displaying greater neovascularization with H&E stain. Similar results were obtained with picrosirius red, which revealed in the polyurethane group a much greater number of vessels than in the silicone group (p=0.001). The collagen area was larger in the polyurethane group, significantly at 28 days (p=0.001) and at two months (p=0.030). Polyurethane foam elicited more intense foreign-body reaction when compared with silicone foam. The number of vessels was higher in the capsules of the polyurethane foam implants 28 days after the operation. The capsule of the polyurethane foam implants showed a greater amount of collagen than that of the silicone foam implants.
NASA Technical Reports Server (NTRS)
Goldstein, A. S.; Zhu, G.; Morris, G. E.; Meszlenyi, R. K.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
1999-01-01
Poly(DL-lactic-co-glycolic acid) (PLGA) foams are an osteoconductive support that holds promise for the development of bone tissue in vitro and implantation into orthopedic defects. Because it is desirable that foams maintain their shape and size, we examined a variety of foams cultured in vitro with osteoblastic cells. Foams were prepared with different porosities and pore sizes by the method of solvent casting/porogen leaching using 80, 85, and 90 wt% NaCl sieved with particle sizes of 150-300 and 300-500 microm and characterized by mercury intrusion porosimetry. Foams seeded with cells were found to have volumes after 7 days in static culture that decreased with increasing porosity: the least porous exhibited no change in volume while the most porous foams decreased by 39 +/- 10%. In addition, a correlation was observed between decreasing foam volume after 7 days in culture and decreasing internal surface area of the foams prior to seeding. Furthermore, foams prepared with the 300-500 microm porogen had lower porosities, greater mean wall thicknesses between adjacent pores, and larger volumes after 7 days in culture than those prepared with the smaller porogen. Two culture conditions for maintaining cells, static and agitated (in a rotary vessel), were found to have similar influences on foam size, cell density, and osteoblastic function for 7 and 14 days in culture. Finally, we examined unseeded foams in aqueous solutions of pH 3.0, 5.0, and 7.4 and found no significant decrease in foam size with degradation. This study demonstrates that adherent osteoblastic cells may collapse very porous PLGA foams prepared by solvent casting/particulate leaching: a potentially undesirable property for repair of orthopedic defects.
Biocompatibility of 17-4 PH stainless steel foam for implant applications.
Mutlu, Ilven; Oktay, Enver
2011-01-01
In this study, biocompatibility of 17-4 PH stainless steel foam for biomedical implant applications was investigated. 17-4 PH stainless steel foams having porosities in the range of 40-82% with an average pore size of around 600 μm were produced by space holder-sintering technique. Sintered foams were precipitation hardened for times of 1-6 h at temperatures between 450-570 °C. Compressive yield strength and Young's modulus of aged stainless steel foams were observed to vary between 80-130 MPa and 0.73-1.54 GPa, respectively. Pore morphology, pore size and the mechanical properties of the 17-4 PH stainless steel foams were close to cancellous bone. In vitro evaluations of cytotoxicity of the foams were investigated by XTT and MTT assays and showed sufficient biocompatibility. Surface roughness parameters of the stainless steel foams were also determined to characterize the foams.
Primary Stability of Zirconium vs Titanium Implants: An In Vitro Comparison
2015-06-05
Zirconia implant and 4x11.5 Titanium implant placed in artificial bone ( polyurethane foam ) at .08 rotations /sec…………………………………28 viii...measurements as they relate to primary Implant Stability. Artificial Bone made of solid ridged polyurethane foam was used as an alternative test...30 pound per cubic foot solid rigid polyurethane blocks used to substitute human cancellous bone
Arabnejad Khanoki, Sajad; Pasini, Damiano
2012-03-01
Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.
Unosson, Johanna; Montufar, Edgar B; Engqvist, Håkan; Ginebra, Maria-Pau; Persson, Cecilia
2016-01-01
Resorbable calcium phosphate based bone void fillers should work as temporary templates for new bone formation. The incorporation of macropores with sizes of 100 -300 µm has been shown to increase the resorption rate of the implant and speed up bone ingrowth. In this work, macroporous brushite cements were fabricated through foaming of the cement paste, using two different synthetic surfactants, Tween® 80 and Pluronic® F-127. The macropores formed in the Pluronic samples were both smaller and less homogeneously distributed compared with the pores formed in the Tween samples. The porosity and compressive strength (CS) were comparable to previously developed hydroxyapatite foams. The cement foam containing Tween, 0.5M citric acid in the liquid, 1 mass% of disodium dihydrogen pyrophosphate mixed in the powder and a liquid to powder ratio of 0.43 mL/g, showed the highest porosity values (76% total and 56% macroporosity), while the CS was >1 MPa, that is, the hardened cement could be handled without rupture of the foamed structure. The investigated brushite foams show potential for future clinical use, both as bone void fillers and as scaffolds for in vitro bone regeneration. © 2015 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc.
Porous NiTi for bone implants: a review.
Bansiddhi, A; Sargeant, T D; Stupp, S I; Dunand, D C
2008-07-01
NiTi foams are unique among biocompatible porous metals because of their high recovery strain (due to the shape-memory or superelastic effects) and their low stiffness facilitating integration with bone structures. To optimize NiTi foams for bone implant applications, two key areas are under active study: synthesis of foams with optimal architectures, microstructure and mechanical properties; and tailoring of biological interactions through modifications of pore surfaces. This article reviews recent research on NiTi foams for bone replacement, focusing on three specific topics: (i) surface modifications designed to create bio-inert porous NiTi surfaces with low Ni release and corrosion, as well as bioactive surfaces to enhance and accelerate biological activity; (ii) in vitro and in vivo biocompatibility studies to confirm the long-term safety of porous NiTi implants; and (iii) biological evaluations for specific applications, such as in intervertebral fusion devices and bone tissue scaffolds. Possible future directions for bio-performance and processing studies are discussed that could lead to optimized porous NiTi implants.
Porous NiTi for bone implants: A review
Bansiddhi, A.; Sargeant, T.D.; Stupp, S.I.; Dunand, D.C.
2011-01-01
NiTi foams are unique among biocompatible porous metals because of their high recovery strain (due to the shape-memory or superelastic effects) and their low stiffness facilitating integration with bone structures. To optimize NiTi foams for bone implant applications, two key areas are under active study: synthesis of foams with optimal architectures, microstructure and mechanical properties; and tailoring of biological interactions through modifications of pore surfaces. This article reviews recent research on NiTi foams for bone replacement, focusing on three specific topics: (i) surface modifications designed to create bio-inert porous NiTi surfaces with low Ni release and corrosion, as well as bioactive surfaces to enhance and accelerate biological activity; (ii) In vitro and in vivo biocompatibility studies to confirm the long-term safety of porous NiTi implants; and (iii) biological evaluations for specific applications, such as in intervertebral fusion devices and bone tissue scaffolds. Possible future directions for bio-performance and processing studies are discussed that could lead to optimized porous NiTi implants. PMID:18348912
de la Peña-Salcedo, Jose Abel; Soto-Miranda, Miguel Angel; Lopez-Salguero, Jose Fernando
2012-04-01
Implants with a polyurethane foam cover have been used by plastic surgeons since Ashley described them in 1970. Overwhelming evidence confirms the benefits of these implants, especially the extremely low incidence of capsular contracture (grades 3 and 4, Baker classification). On the other hand, except for a transient and self-limited rash, there is no evidence that polyurethane implants present more complications than texturized or smooth gel implants. Due to concerns of polyurethane-induced cancer, these implants were withdrawn in United States after approximately 110,000 American women had received them. This fact, together with the probability that these implants will be reintroduced in the United States, suggests that continued monitoring of their long-term safety and effectiveness is mandatory. A retrospective study analyzed the outcomes of 996 implants inserted during a period of 15 years. The incidence of early and late complications was analyzed as well as the aesthetic outcome. The complications evaluated included hematoma (0.6%), infection (0.4%), seroma (0.8%), rash (4.3%), wound dehiscence (0%), capsular contracture (0.4%), implant malposition (0.8%), need for revisional surgery (1.2%), implant rupture (0.7%), rippling (1.8%), and polyurethane-related cancer (0%). Regarding the aesthetic outcome, 95% of the patients expressed satisfaction with their final result. The polyurethane foam-covered implants have been proven safe for use in breast surgery. They provide the lowest rate of capsular contracture (0.4% in the current study) and excellent aesthetic results.
Hybrid bone implants: self-assembly of peptide amphiphile nanofibers within porous titanium.
Sargeant, Timothy D; Guler, Mustafa O; Oppenheimer, Scott M; Mata, Alvaro; Satcher, Robert L; Dunand, David C; Stupp, Samuel I
2008-01-01
Over the past few decades there has been great interest in the use of orthopedic and dental implants that integrate into tissue by promoting bone ingrowth or bone adhesion, thereby eliminating the need for cement fixation. However, strategies to create bioactive implant surfaces to direct cellular activity and mineralization leading to osteointegration are lacking. We report here on a method to prepare a hybrid bone implant material consisting of a Ti-6Al-4V foam, whose 52% porosity is filled with a peptide amphiphile (PA) nanofiber matrix. These PA nanofibers can be highly bioactive by molecular design, and are used here as a strategy to transform an inert titanium foam into a potentially bioactive implant. Using scanning electron microscopy (SEM) and confocal microscopy, we show that PA molecules self-assemble into a nanofiber matrix within the pores of the metallic foam, fully occupying the foam's interconnected porosity. Furthermore, the method allows the encapsulation of cells within the bioactive matrix, and under appropriate conditions the nanofibers can nucleate mineralization of calcium phosphate phases with a Ca:P ratio that corresponds to that of hydroxyapatite. Cell encapsulation was quantified using a DNA measuring assay and qualitatively verified by SEM and confocal microscopy. An in vivo experiment was performed using a bone plug model in the diaphysis of the hind femurs of a Sprague Dawley rat and examined by histology to evaluate the performance of these hybrid systems after 4 weeks of implantation. Preliminary results demonstrate de novo bone formation around and inside the implant, vascularization around the implant, as well as the absence of a cytotoxic response. The PA-Ti hybrid strategy could be potentially tailored to initiate mineralization and direct a cellular response from the host tissue into porous implants to form new bone and thereby improve fixation, osteointegration, and long term stability of implants.
Huh, Jung-Bo; Lee, Jeong-Yeol; Jeon, Young-Chan; Shin, Sang-Wan; Ahn, Jin-Soo; Ryu, Jae-Jun
2013-05-01
The aim of this study was to evaluate the stability of arginine-glycine-aspartic acid (RGD) peptide coatings on implants by measuring the amount of peptide remaining after installation. Fluorescent isothiocyanate (FITC)-fixed RGD peptide was coated onto anodized titanium implants (width 4 mm, length 10 mm) using a physical adsorption method (P) or a chemical grafting method (C). Solid Rigid Polyurethane Foam (SRPF) was classified as either hard bone (H) or soft bone (S) according to its density. Two pieces of artificial bone were fixed in a customized jig, and coated implants were installed at the center of the boundary between two pieces of artificial bone. The test groups were classified as: P-H, P-S, C-H, or C-S. After each installation, implants were removed from the SRPF, and the residual amounts and rates of RGD peptide in implants were measured by fluorescence spectrometry. The Kruskal-Wallis test was used for the statistical analysis (α=0.05). Peptide-coating was identified by fluorescence microscopy and XPS. Total coating amount was higher for physical adsorption than chemical grafting. The residual rate of peptide was significantly larger in the P-S group than in the other three groups (P<.05). The result of this study suggests that coating doses depend on coating method. Residual amounts of RGD peptide were greater for the physical adsorption method than the chemical grafting method.
Biomechanical evaluation of CIBOR spine interbody fusion device.
Chong, Alexander C M; Harrer, Seth W; Heggeness, Michael H; Wooley, Paul H
2017-07-01
The CIBOR PEEK spinal interbody fusion device is an anterior lumbar interbody fusion construct with a hollow center designed to accommodate an osteoinductive carbon foam insert to promote bony ingrowth to induce fusion where rigid stabilization is needed. Three different sizes of the device were investigated. Part-I: implants were tested under axial compression and rotation using polyurethane foam blocks. Part-II: simulated 2-legged stance using cadaveric specimen using the L5-S1 lumbar spine segment. Part-III: a survey feedback form was used to investigate two orthopedic surgeons concern regarding the implant. In Part-I, the subsidence hysteresis under axial compression loading was found to be statistical significant difference between these three implant sizes. It was noted that the implants had migration as rotation applied, and the amount of subsidence was a factor of the axial compression loads applied. In Part-II, a minor subsidence and carbon foam debris were observed when compared to each implant size. Poor contact surface of the implant with the end plates of the L5 or S1 vertebrae from the anterior view under maximum loads was observed; however, the implant seemed to be stable. Each surgeon has their own subjective opinion about the CIBOR implant. Two out of the three different sizes of the device (medium and large sizes) provided appropriate rigid stabilization at the physiological loads. Neither orthopedic surgeon was 100% satisfied with overall performance of the implant, but felt potential improvement could be made. This study indicates an option for operative treatment of spine interbody fusion, as the CIBOR spine interbody fusion device has a hollow center. This hollow center is designed to accommodate a carbon foam insert to promote bony ingrowth. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1157-1168, 2017. © 2016 Wiley Periodicals, Inc.
Lips, Katrin Susanne; Kauschke, Vivien; Hartmann, Sonja; Thormann, Ulrich; Ray, Seemun; Kampschulte, Marian; Langheinrich, Alexander; Schumacher, Matthias; Gelinsky, Michael; Heinemann, Sascha; Hanke, Thomas; Kautz, Armin R; Schnabelrauch, Matthias; Schnettler, Reinhard; Heiss, Christian; Alt, Volker; Kilian, Olaf
2013-01-01
Insertion of bone substitution materials accelerates healing of osteoporotic fractures. Biodegradable materials are preferred for application in osteoporotic patients to avoid a second surgery for implant replacement. Degraded implant fragments are often absorbed by macrophages that are removed from the fracture side via passage through veins or lymphatic vessels. We investigated if lymphatic vessels occur in osteoporotic bone defects and whether they are regulated by the use of different materials. To address this issue osteoporosis was induced in rats using the classical method of bilateral ovariectomy and additional calcium and vitamin deficient diet. In addition, wedge-shaped defects of 3, 4, or 5 mm were generated in the distal metaphyseal area of femur via osteotomy. The 4 mm defects were subsequently used for implantation studies where bone substitution materials of calcium phosphate cement, composites of collagen and silica, and iron foams with interconnecting pores were inserted. Different materials were partly additionally functionalized by strontium or bisphosphonate whose positive effects in osteoporosis treatment are well known. The lymphatic vessels were identified by immunohistochemistry using an antibody against podoplanin. Podoplanin immunopositive lymphatic vessels were detected in the granulation tissue filling the fracture gap, surrounding the implant and growing into the iron foam through its interconnected pores. Significant more lymphatic capillaries were counted at the implant interface of composite, strontium and bisphosphonate functionalized iron foam. A significant increase was also observed in the number of lymphatics situated in the pores of strontium coated iron foam. In conclusion, our results indicate the occurrence of lymphatic vessels in osteoporotic bone. Our results show that lymphatic vessels are localized at the implant interface and in the fracture gap where they might be involved in the removal of lymphocytes, macrophages, debris and the implants degradation products. Therefore the lymphatic vessels are involved in implant integration and fracture healing.
Lips, Katrin Susanne; Kauschke, Vivien; Hartmann, Sonja; Thormann, Ulrich; Ray, Seemun; Kampschulte, Marian; Langheinrich, Alexander; Schumacher, Matthias; Gelinsky, Michael; Heinemann, Sascha; Hanke, Thomas; Kautz, Armin R.; Schnabelrauch, Matthias; Schnettler, Reinhard; Heiss, Christian; Alt, Volker; Kilian, Olaf
2013-01-01
Insertion of bone substitution materials accelerates healing of osteoporotic fractures. Biodegradable materials are preferred for application in osteoporotic patients to avoid a second surgery for implant replacement. Degraded implant fragments are often absorbed by macrophages that are removed from the fracture side via passage through veins or lymphatic vessels. We investigated if lymphatic vessels occur in osteoporotic bone defects and whether they are regulated by the use of different materials. To address this issue osteoporosis was induced in rats using the classical method of bilateral ovariectomy and additional calcium and vitamin deficient diet. In addition, wedge-shaped defects of 3, 4, or 5 mm were generated in the distal metaphyseal area of femur via osteotomy. The 4 mm defects were subsequently used for implantation studies where bone substitution materials of calcium phosphate cement, composites of collagen and silica, and iron foams with interconnecting pores were inserted. Different materials were partly additionally functionalized by strontium or bisphosphonate whose positive effects in osteoporosis treatment are well known. The lymphatic vessels were identified by immunohistochemistry using an antibody against podoplanin. Podoplanin immunopositive lymphatic vessels were detected in the granulation tissue filling the fracture gap, surrounding the implant and growing into the iron foam through its interconnected pores. Significant more lymphatic capillaries were counted at the implant interface of composite, strontium and bisphosphonate functionalized iron foam. A significant increase was also observed in the number of lymphatics situated in the pores of strontium coated iron foam. In conclusion, our results indicate the occurrence of lymphatic vessels in osteoporotic bone. Our results show that lymphatic vessels are localized at the implant interface and in the fracture gap where they might be involved in the removal of lymphocytes, macrophages, debris and the implants degradation products. Therefore the lymphatic vessels are involved in implant integration and fracture healing. PMID:24130867
Murr, L E; Amato, K N; Li, S J; Tian, Y X; Cheng, X Y; Gaytan, S M; Martinez, E; Shindo, P W; Medina, F; Wicker, R B
2011-10-01
Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platelets while the mesh and foam structures were characterized by α(')-martensite with some residual α. The Co-29Cr-6Mo containing 0.22% C formed columnar (directional) Cr(23)C(6) carbides spaced ~2 μm in the build direction, while HIP-annealed Co-Cr alloy exhibited an intrinsic stacking fault microstructure. A log-log plot of relative stiffness versus relative density for Ti-6Al-4V and Co-29Cr-6Mo open-cellular mesh and foams resulted in a fitted line with a nearly ideal slope, n = 2.1. A stress shielding design graph constructed from these data permitted mesh and foam implant prototypes to be fabricated for compatible bone stiffness. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lopez, C.; Muñoz, J. C.; Pinillos, J. C.
2013-11-01
The main purpose of this research was to achieve a better understanding of the relationship within the mechanical properties of human cadaver jaw bone with kind D2 density regarding a substitute polymer to simulate bone tissue, proposed by the ASTM, to evaluate orthopedic implants. However, despite the existence of several densities of foams and his mechanical characterization has been classified into different degrees of tissue densities to simulate cancellous and cortical bone, the value of the densities are different contrasted with the densities of bone tissue, making difficult to establish direct relationship about mechanical behavior between the polymer and the bone material, and therefore no clear criteria known for choosing the polymeric foam which describes the mechanical behavior of tissue for a specific or particular study. To understand such behavior from bone tissue regarding the polymer samples, on this research was a dental implant inserted into the samples, and subjected to destructive Pull Out test according to ASTM F543The Pull Out strength was compared between implant-jawbone and implant-rigid polyurethane foam interfaces. Thus, the test pieces with mechanical behavior similar to bone tissue, enabling an approximation to choose degree appropriate of polymer to replace the bone tissue in future trials biomechanical.
Silva, Eduardo Nascimento; Ribas-Filho, Jurandir Marcondes; Czeczko, Nicolau Gregori; Pachnicki, Jan Pawel Andrade; Netto, Mário Rodrigues Montemor; Lipinski, Leandro Cavalcante; Noronha, Lucia de; Colman, Joelmir; Zeni, João Otavio; Carvalho, Caroline Aragão de
2016-12-01
To assess the capsules formed by silicone implants coated with polyurethane foam and with a textured surface. Sixty-four Wistar albinus rats were divided into two groups of 32 each using polyurethane foam and textured surface. The capsules around the implants were analyzed for 30, 50, 70 and 90 days. Were analyzed the following parameters: foreign body reaction, granulation tissue, presence of myofibroblasts, neoangiogenesis, presence of synovial metaplasia, capsular thickness, total area and collagen percentage of type I and III, in capsules formed around silicone implants in both groups. The foreign body reaction was only present in the four polyurethane subgroups. The formation of granulation tissue and the presence of myofibroblasts were higher in the four polyurethane subgroups. Regarding to neoangiogenesis and synovial metaplasia, there was no statistical difference between the groups. Polyurethane group presented (all subgroups) a greater capsule thickness, a smaller total area and collagen percentage of type I and a higher percentage area of type III, with statistical difference. The use of polyurethane-coated implants should be stimulated by the long-term results in a more stable capsule and a lower incidence of capsular contracture, despite developing a more intense and delayed inflammatory reaction in relation to implants with textured surface.
Montufar, Edgar B.; Engqvist, Håkan; Ginebra, Maria‐Pau; Persson, Cecilia
2016-01-01
Abstract Resorbable calcium phosphate based bone void fillers should work as temporary templates for new bone formation. The incorporation of macropores with sizes of 100 −300 µm has been shown to increase the resorption rate of the implant and speed up bone ingrowth. In this work, macroporous brushite cements were fabricated through foaming of the cement paste, using two different synthetic surfactants, Tween® 80 and Pluronic® F‐127. The macropores formed in the Pluronic samples were both smaller and less homogeneously distributed compared with the pores formed in the Tween samples. The porosity and compressive strength (CS) were comparable to previously developed hydroxyapatite foams. The cement foam containing Tween, 0.5M citric acid in the liquid, 1 mass% of disodium dihydrogen pyrophosphate mixed in the powder and a liquid to powder ratio of 0.43 mL/g, showed the highest porosity values (76% total and 56% macroporosity), while the CS was >1 MPa, that is, the hardened cement could be handled without rupture of the foamed structure. The investigated brushite foams show potential for future clinical use, both as bone void fillers and as scaffolds for in vitro bone regeneration. © 2015 The Authors. Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 67–77, 2016. PMID:25615405
Platinum concentration in silicone breast implant material and capsular tissue by ICP-MS.
Maharaj, S V M
2004-09-01
Inductively coupled plasma-mass spectrometry (ICP-MS) was used to determine the concentration of platinum (Pt) in silicone breast implant gel (range, 0.26-48.90 microg g(-1) Pt; n=15), elastomer (range, 3.05-28.78 microg g(-1) Pt; n=7), double lumen (range, 5.79-125.27 microg g(-1) Pt; n=7), foam (range, 5.79-8.36 microg g(-1) Pt; n=2), and capsular tissue (range, 0.003-0.272 microg g(-1) Pt; n=15). The results show that very high levels of Pt are present in the encasing elastomer, double lumen, and foam envelope materials. Silicone breast implants can be a source of significant Pt exposure for individuals with these implants.
Kougias, P G; Boe, K; Einarsdottir, E S; Angelidaki, I
2015-08-01
Foaming is one of the major operational problems in biogas plants, and dealing with foaming incidents is still based on empirical practices. Various types of antifoams are used arbitrarily to combat foaming in biogas plants, but without any scientific support this action can lead to serious deterioration of the methanogenic process. Many commercial antifoams are derivatives of fatty acids or oils. However, it is well known that lipids can induce foaming in manure based biogas plants. This study aimed to elucidate the effect of rapeseed oil and oleic acid on foam reduction and process performance in biogas reactors fed with protein or lipid rich substrates. The results showed that both antifoams efficiently suppressed foaming. Moreover rapeseed oil resulted in stimulation of the biogas production. Finally, it was reckoned that the chemical structure of lipids, and more specifically their carboxylic ends, is responsible for their foam promoting or foam counteracting behaviour. Thus, it was concluded that the fatty acids and oils could suppress foaming, while salt of fatty acids could generate foam. Copyright © 2015 Elsevier Ltd. All rights reserved.
Exploratory development of foams from liquid crystal polymers
NASA Technical Reports Server (NTRS)
Chung, T. S.
1985-01-01
Two types of liquid crystal polymer (LCP) compositions were studied and evaluated as structural foam materials. One is a copolymer of 6-hydroxy-2-naphthoic acid, terephthalic acid, and p-acetoxyacetanilide (designed HNA/TA/AAA), and the other is a copolymer of p-hydroxybenzoic acid and 6-hydroxy-2-naphthoic acid (designated HBA/HNA). Experimental results showed that the extruded HNA/TA/AA foams have better mechanical quality and appearance than HBA/HNA foams. Heat treatment improved foam tensile strength and break elongation, but reduced their modulus. The injection molding results indicated that nitrogen foaming agents with a low-pressure process gave better void distribution in the injection molded LCP foams than those made by the conventional injection-molding machine and chemical blowing agents. However, in comparing LCP foams with other conventional plastic foams, HBA/HNA foams have better mechanical properties than foamed ABS and PS, but are comparable to PBT and inferior to polycarbonate foams, especially in heat-deflection temperature and impact resistance energy. These deficiencies are due to LCP molecules not having been fully oriented during the Union-Carbide low-pressure foaming process.
Rodriguez, Jennifer N.; Clubb, Fred J.; Wilson, Thomas S.; Miller, Matthew W.; Fossum, Theresa W.; Hartman, Jonathan; Tuzun, Egemen; Singhal, Pooja; Maitland, Duncan J.
2014-01-01
Cerebral aneurysms treated by traditional endovascular methods using platinum coils have a tendency to be unstable, either due to chronic inflammation, compaction of coils, or growth of the aneurysm. We propose to use alternate filling methods for the treatment of intracranial aneurysms using polyurethane based shape memory polymer (SMP) foams. SMP polyurethane foams were surgically implanted in a porcine aneurysm model to determine biocompatibility, localized thrombogenicity, and their ability to serve as a stable filler material within an aneurysm. The degree of healing was evaluated via gross observation, histopathology and low vacuum scanning electron microscopy (LV-SEM) imaging after zero, thirty and ninety days. Clotting was initiated within the SMP foam at time zero (less than one hour exposure to blood prior to euthanization), partial healing was observed at thirty days, and almost complete healing had occurred at ninety days in vivo, with minimal inflammatory response. PMID:23650278
In vivo response to an implanted shape memory polyurethane foam in a porcine aneurysm model.
Rodriguez, Jennifer N; Clubb, Fred J; Wilson, Thomas S; Miller, Matthew W; Fossum, Theresa W; Hartman, Jonathan; Tuzun, Egemen; Singhal, Pooja; Maitland, Duncan J
2014-05-01
Cerebral aneurysms treated by traditional endovascular methods using platinum coils have a tendency to be unstable, either due to chronic inflammation, compaction of coils, or growth of the aneurysm. We propose to use alternate filling methods for the treatment of intracranial aneurysms using polyurethane-based shape memory polymer (SMP) foams. SMP polyurethane foams were surgically implanted in a porcine aneurysm model to determine biocompatibility, localized thrombogenicity, and their ability to serve as a stable filler material within an aneurysm. The degree of healing was evaluated via gross observation, histopathology, and low vacuum scanning electron microscopy imaging after 0, 30, and 90 days. Clotting was initiated within the SMP foam at time 0 (<1 h exposure to blood before euthanization), partial healing was observed at 30 days, and almost complete healing had occurred at 90 days in vivo, with minimal inflammatory response. Copyright © 2013 Wiley Periodicals, Inc.
Self-fitting shape memory polymer foam inducing bone regeneration: A rabbit femoral defect study.
Xie, Ruiqi; Hu, Jinlian; Hoffmann, Oskar; Zhang, Yuanchi; Ng, Frankie; Qin, Tingwu; Guo, Xia
2018-04-01
Although tissue engineering has been attracted greatly for healing of critical-sized bone defects, great efforts for improvement are still being made in scaffold design. In particular, bone regeneration would be enhanced if a scaffold precisely matches the contour of bone defects, especially if it could be implanted into the human body conveniently and safely. In this study, polyurethane/hydroxyapatite-based shape memory polymer (SMP) foam was fabricated as a scaffold substrate to facilitate bone regeneration. The minimally invasive delivery and the self-fitting behavior of the SMP foam were systematically evaluated to demonstrate its feasibility in the treatment of bone defects in vivo. Results showed that the SMP foam could be conveniently implanted into bone defects with a compact shape. Subsequently, it self-matched the boundary of bone defects upon shape-recovery activation in vivo. Micro-computed tomography determined that bone ingrowth initiated at the periphery of the SMP foam with a constant decrease towards the inside. Successful vascularization and bone remodeling were also demonstrated by histological analysis. Thus, our results indicate that the SMP foam demonstrated great potential for bone regeneration. Copyright © 2018 Elsevier B.V. All rights reserved.
Influence of Drilling Speed on Stability of Tapered Dental Implants: An Ex Vivo Experimental Study.
Almeida, Karen P; Delgado-Ruiz, Rafael; Carneiro, Leandro G; Leiva, Alberto Bordonaba; Calvo-Guirado, Jose Luis; Gómez-Moreno, Gerardo; Malmström, Hans; Romanos, Georgios E
2016-01-01
The aim of this study was to evaluate whether the drilling speed used during implant site preparation influences primary stability. Eighty tapered designed implants (3.8 × 10 mm) were inserted following osteotomies created in solid rigid polyurethane foam (simulating bone type II) and cellular rigid polyurethane foam (simulating bone type IV). Half were prepared using drilling speeds of 800 rpm (low speed), and the other half were prepared using speeds of 1,500 rpm (high speed). Following insertion, implant primary stability was measured using Periotest and Osstell (resonance frequency analysis [RFA]) devices. Two-way analysis of variance (ANOVA) used for this study found that the drilling speed used to create the osteotomies appeared to have no significant impact on primary stability. The bone quality and not the osteotomy drilling speed seems to influence the implant primary stability.
Micro-engineered first wall tungsten armor for high average power laser fusion energy systems
NASA Astrophysics Data System (ADS)
Sharafat, Shahram; Ghoniem, Nasr M.; Anderson, Michael; Williams, Brian; Blanchard, Jake; Snead, Lance; HAPL Team
2005-12-01
The high average power laser program is developing an inertial fusion energy demonstration power reactor with a solid first wall chamber. The first wall (FW) will be subject to high energy density radiation and high doses of high energy helium implantation. Tungsten has been identified as the candidate material for a FW armor. The fundamental concern is long term thermo-mechanical survivability of the armor against the effects of high temperature pulsed operation and exfoliation due to the retention of implanted helium. Even if a solid tungsten armor coating would survive the high temperature cyclic operation with minimal failure, the high helium implantation and retention would result in unacceptable material loss rates. Micro-engineered materials, such as castellated structures, plasma sprayed nano-porous coatings and refractory foams are suggested as a first wall armor material to address these fundamental concerns. A micro-engineered FW armor would have to be designed with specific geometric features that tolerate high cyclic heating loads and recycle most of the implanted helium without any significant failure. Micro-engineered materials are briefly reviewed. In particular, plasma-sprayed nano-porous tungsten and tungsten foams are assessed for their potential to accommodate inertial fusion specific loads. Tests show that nano-porous plasma spray coatings can be manufactured with high permeability to helium gas, while retaining relatively high thermal conductivities. Tungsten foams where shown to be able to overcome thermo-mechanical loads by cell rotation and deformation. Helium implantation tests have shown, that pulsed implantation and heating releases significant levels of implanted helium. Helium implantation and release from tungsten was modeled using an expanded kinetic rate theory, to include the effects of pulsed implantations and thermal cycles. Although, significant challenges remain micro-engineered materials are shown to constitute potential candidate FW armor materials.
The Efficacy and Safety of Azelaic Acid 15% Foam in the Treatment of Facial Acne Vulgaris.
Hashim, Peter W; Chen, Tinley; Harper, Julie C; Kircik, Leon H
2018-06-01
Azelaic acid demonstrates anti-inflammatory, anti-oxidative, anti-comedogenic, and anti-microbial effects. Azelaic acid 20% cream is currently approved for the treatment of acne vulgaris, and azelaic acid 15% foam has recently been approved for rosacea. Given the favorable tolerability profile of foam preparations, it is reasonable to assume that azelaic acid 15% foam could serve as a viable treatment option for facial acne. To examine the efficacy and safety of azelaic acid 15% foam in the treatment of moderate-to-severe facial acne Methods: Twenty subjects with moderate-to-severe facial acne vulgaris were enrolled in this two-center, open-label pilot study. All study subjects were treated with azelaic acid 15% foam for 16 weeks. Efficacy analyses were based on the change in facial investigator global assessment (FIGA) and changes in total, inflammatory, non-inflammatory lesion counts between baseline and week 16. There was a significant reduction in FIGA scores from baseline to week 16 (p = .0004), with 84% of subjects experiencing at least a 1 grade improvement, and 63% of subjects achieving a final grade of Clear or Almost Clear. All subjects experienced reductions in inflammatory and total lesion counts by week 16, and 89% of subjects experienced reductions in non-inflammatory lesions. Azelaic acid 15% foam was well tolerated, with almost all instances of erythema, dryness, peeling, oiliness, pruritus, and burning being of mild or trace degree, and most adverse effects resolving by the end of the study. Azelaic acid 15% foam is effective and safe in the treatment of facial acne vulgaris. Given the convenience of foam vehicles, azelaic acid 15% foam should be considered as a viable treatment option for this condition. J Drugs Dermatol. 2018;17(6):641-645.
Starch/fiber/poly(lactic acid) foam and compressed foam composites
USDA-ARS?s Scientific Manuscript database
Composites of starch, fiber, and poly(lactic acid) (PLA) were made using a foam substrate formed by dehydrating starch or starch/fiber gels. PLA was infiltrated into the dry foam to provide better moisture resistance. Foam composites were compressed into plastics using force ranging from 4-76MPa. Te...
Kemp, Belinda; Condé, Bruna; Jégou, Sandrine; Howell, Kate; Vasserot, Yann; Marchal, Richard
2018-02-08
The visual properties of sparkling wine including foam and bubbles are an indicator of sparkling wine quality. Foam properties, particularly foam height (FH) and foam stability (TS), are significantly influenced by the chemical composition of the wine. This review investigates our current knowledge of specific chemical compounds and, the mechanisms by which they influence the foam properties of sparkling wines. Grape and yeast proteins, amino acids, polysaccharides, phenolic compounds, organic acids, fatty acids, ethanol and sugar are examined with respect to their contribution to foam characteristics in sparkling wines made with the Traditional, Transfer, and Charmat and carbonation methods. Contradictory results have been identified that appear to be due to the analytical methods used to measure and quantify compounds and foam. Biopolymer complexes are discussed and absent knowledge with regards to thaumatin-like proteins (TLPs), polysaccharides, amino acids, oak-derived phenolic compounds and organic acids are identified. Future research is also likely to concentrate on visual analysis of sparkling wines by in-depth imaging analysis and specific sensory analysis techniques.
Harold Goldstein (R) and Dan Leiser (L) discuss bone implant development in the the Shuttle Tile
NASA Technical Reports Server (NTRS)
1993-01-01
Harold Goldstein (R) and Dan Leiser (L) discuss bone implant development in the the Shuttle Tile Laboratory N-242. A spin-off of Ames research on both bone density in microgravity and on thermal protection foams is the bone-growth implant shown in 1993.
Kelly, N; Cawley, D T; Shannon, F J; McGarry, J P
2013-11-01
The stress distribution and plastic deformation of peri-prosthetic trabecular bone during press-fit tibial component implantation in total knee arthroplasty is investigated using experimental and finite element techniques. It is revealed that the computed stress distribution, implantation force and plastic deformation in the trabecular bone is highly dependent on the plasticity formulation implemented. By incorporating pressure dependent yielding using a crushable foam plasticity formulation to simulate the trabecular bone during implantation, highly localised stress concentrations and plastic deformation are computed at the bone-implant interface. If the pressure dependent yield is neglected using a traditional von Mises plasticity formulation, a significantly different stress distribution and implantation force is computed in the peri-prosthetic trabecular bone. The results of the study highlight the importance of: (i) simulating the insertion process of press-fit stem implantation; (ii) implementing a pressure dependent plasticity formulation, such as the crushable foam plasticity formulation, for the trabecular bone; (iii) incorporating friction at the implant-bone interface during stem insertion. Simulation of the press-fit implantation process with an appropriate pressure dependent plasticity formulation should be implemented in the design and assessment of arthroplasty prostheses. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Yaman, Bilge; Onuklu, Eren; Korpe, Nese O.
2017-09-01
Pure Al and alumina (2, 5, 10 wt.% Al2O3)-added Al composite foams were fabricated through powder metallurgy technique, where boric acid (H3BO3) is employed as a new alternative foaming agent. It is aimed to determine the effects of boric acid on the foaming behavior and cellular structure and also purposed to develop the mechanical properties of Al foams by addition of Al2O3. Al and Al composite foams with porosity fraction in the range of 46-53% were achieved by sintering at 620 °C for 2 h. Cell morphology was characterized using a combination of stereomicroscope equipped with image analyzer and scanning electron microscopy. Microhardness values were measured via using Vickers indentation technique. Quasi-static compression tests were performed at strain rate of 10-3 s-1. Compressive strength and energy absorption of the composite foams enhanced not only by the increasing weight fraction of alumina, but also by the usage of boric acid which leads to formation of boron oxide (B2O3) acting as a binder in obtaining dense cell walls. The results revealed that the boric acid has outstanding potential as foaming agent in the fabrication of Al and Al composite foams by providing improved mechanical properties.
Zhang, Jingtao; Liu, Weizhen; Gauthier, Olivier; Sourice, Sophie; Pilet, Paul; Rethore, Gildas; Khairoun, Khalid; Bouler, Jean-Michel; Tancret, Franck; Weiss, Pierre
2016-02-01
In this study, we propose a simple and effective strategy to prepare injectable macroporous calcium phosphate cements (CPCs) by syringe-foaming via hydrophilic viscous polymeric solution, such as using silanized-hydroxypropyl methylcellulose (Si-HPMC) as a foaming agent. The Si-HPMC foamed CPCs demonstrate excellent handling properties such as injectability and cohesion. After hardening the foamed CPCs possess hierarchical macropores and their mechanical properties (Young's modulus and compressive strength) are comparable to those of cancellous bone. Moreover, a preliminary in vivo study in the distal femoral sites of rabbits was conducted to evaluate the biofunctionality of this injectable macroporous CPC. The evidence of newly formed bone in the central zone of implantation site indicates the feasibility and effectiveness of this foaming strategy that will have to be optimized by further extensive animal experiments. A major challenge in the design of biomaterial-based injectable bone substitutes is the development of cohesive, macroporous and self-setting calcium phosphate cement (CPC) that enables rapid cell invasion with adequate initial mechanical properties without the use of complex processing and additives. Thus, we propose a simple and effective strategy to prepare injectable macroporous CPCs through syringe-foaming using a hydrophilic viscous polymeric solution (silanized-hydroxypropyl methylcellulose, Si-HPMC) as a foaming agent, that simultaneously meets all the aforementioned aims. Evidence from our in vivo studies shows the existence of newly formed bone within the implantation site, indicating the feasibility and effectiveness of this foaming strategy, which could be used in various CPC systems using other hydrophilic viscous polymeric solutions. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Compliant Buckled Foam Actuators and Application in Patient-Specific Direct Cardiac Compression.
Mac Murray, Benjamin C; Futran, Chaim C; Lee, Jeanne; O'Brien, Kevin W; Amiri Moghadam, Amir A; Mosadegh, Bobak; Silberstein, Meredith N; Min, James K; Shepherd, Robert F
2018-02-01
We introduce the use of buckled foam for soft pneumatic actuators. A moderate amount of residual compressive strain within elastomer foam increases the applied force ∼1.4 × or stroke ∼2 × compared with actuators without residual strain. The origin of these improved characteristics is explained analytically. These actuators are applied in a direct cardiac compression (DCC) device design, a type of implanted mechanical circulatory support that avoids direct blood contact, mitigating risks of clot formation and stroke. This article describes a first step toward a pneumatically powered, patient-specific DCC design by employing elastomer foam as the mechanism for cardiac compression. To form the device, a mold of a patient's heart was obtained by 3D printing a digitized X-ray computed tomography or magnetic resonance imaging scan into a solid model. From this model, a soft, robotic foam DCC device was molded. The DCC device is compliant and uses compressed air to inflate foam chambers that in turn apply compression to the exterior of a heart. The device is demonstrated on a porcine heart and is capable of assisting heart pumping at physiologically relevant durations (∼200 ms for systole and ∼400 ms for diastole) and stroke volumes (∼70 mL). Although further development is necessary to produce a fully implantable device, the material and processing insights presented here are essential to the implementation of a foam-based, patient-specific DCC design.
Effect of blowing agents on the oxidation resistance of carbon foams prepared from molten sucrose
NASA Astrophysics Data System (ADS)
Narasimman, R.; Prabhakaran, K.
2013-06-01
We have prepared low density carbon foams from molten sucrose using aluminium nitrate and boric acid blowing agents. A comparative study of the oxidation resistance of the carbon foams prepared using the two blowing agents are reported in the present paper. Oxidation of the carbon foams was evaluated under isothermal and non-isothermal conditions in air atmosphere using thermogravimetric analysis (TGA). We have observed that the alumina produced from the aluminium nitrate blowing agent acts as a catalyst whereas the boron produced from boric acid inhibits the oxidation of the carbon foams. The oxidation resistance of carbon foams increases with boron concentration. The oxidation onset temperature for the carbon foams prepared using boric acid blowing agent was nearly 60°C higher than that prepared using aluminium nitrate blowing agent. Carbon foams prepared using aluminium nitrate blowing agent undergoes complete oxidation at temperature less than 700°C. Whereas that prepared using boric acid blowing agent leave ˜ 50 wt.% residue at 900°C. Further evidence is provided by the kinetic analysis of the TGA using Coats-Redfern (CR) equation.
Foaming phenomenon in bench-scale anaerobic digesters.
Siebels, Amanda M; Long, Sharon C
2013-04-01
The Madison Metropolitan Sewerage District (The District) in Madison, Wisconsin has been experiencing seasonal foaming in their anaerobic biosolids digesters, which has occurred from mid-November to late June for the past few years. The exact cause(s) of foaming is unknown. Previous research findings are unclear as to whether applications of advanced anaerobic digestion processes reduce the foaming potential of digesters. The object of this study was to investigate how configurations of thermophilic and acid phase-thermophilic anaerobic digestion would affect foaming at the bench-scale level compared to single stage mesophilic digestion for The District. Bench-scale anaerobic digesters were fed with a 4 to 4.5% by dry weight of solids content blend of waste activated sludge (WAS) and primary sludge from The District. Foaming potential was monitored using Alka-Seltzer and aeration foaming tests. The bench-scale acid phase-thermophilic digester had a higher foaming potential than the bench-scale mesophilic digester. These results indicate that higher temperatures increase the foaming potential of the bench-scale anaerobic digesters. The bench-scale acid phase-thermophilic digesters had a greater percent (approximately 5 to 10%) volatile solids destruction and a greater percent (approximately 5 to 10%) total solids destruction when compared to the bench-scale mesophilic digester. Overall, for the full-scale foaming experienced by The District, it appears that adding an acid phase or switching to thermophilic digestion would not alleviate The District's foaming issues.
1993-10-07
Harold Goldstein (R) and Dan Leiser (L) discuss bone implant development in the the Shuttle Tile Laboratory N-242. A spin-off of Ames research on both bone density in microgravity and on thermal protection foams is the bone-growth implant shown in 1993.
Ambient cure polyimide foams. [thermal resistant foams
NASA Technical Reports Server (NTRS)
Sawko, P. M.; Riccitiello, S. R.; Hamermesh, C. L. (Inventor)
1978-01-01
Flame and temperature resistant polyimide foams are prepared by the reaction of an aromatic dianhydride, (pyromellitic dianhydride) with an aromatic polyisocyanate, (polymethylene polyphenylisocyanate), in the presence of an inorganic acid and furfuryl alcohol. Usable acids include dilute sulfuric acid, dilute nitric acid, hydrochloric acid, polyphosphoric acid, and phosphoric acid, with the latter being preferred. The dianhydride and the isocyanate in about equimolar proportions constitute about 50% of the reaction mixture, the rest being made up with the acid and the alcohol in a ratio of about 1:10. An exothermic reaction between the acid and the alcohol provides the heat necessary for the other components to polymerize without recourse to external heat sources. The mixture can be sprayed on any surface to form polymeric foam in locations where the application of heat is not practical or possible, for instance, between walls or on mine tunnel surfaces.
Xanthine Oxidase Induces Foam Cell Formation through LOX-1 and NLRP3 Activation.
Dai, Yao; Cao, Yongxiang; Zhang, Zhigao; Vallurupalli, Srikanth; Mehta, Jawahar L
2017-02-01
Xanthine oxidase catalyzes the oxidation of xanthine to uric acid. This process generates excessive reactive oxygen species (ROS) that play an important role in atherogenesis. Recent studies show that LRR and PYD domains-containing protein 3 (NLRP3), a component of the inflammasome, may be involved in the formation of foam cells, a hallmark of atherosclerosis. This study was designed to study the role of various scavenger receptors and NLRP3 inflammasome in xanthine oxidase and uric acid-induced foam cell formation. Human vascular smooth muscle cells (VSMCs) and THP-1 macrophages were treated with xanthine oxidase or uric acid. Xanthine oxidase treatment (of both VSMCs and THP-1 cells) resulted in foam cell formation in concert with generation of ROS and expression of cluster of differentiation 36 (CD36) and oxidized low density lipoprotein (lectin-like) receptor 1 (LOX-1), but not of scavenger receptor A (SRA). Uric acid treatment resulted in foam cell formation, ROS generation and expression of CD36, but not of LOX-1 or SRA. Further, treatment of cells with xanthine oxidase, but not uric acid, activated NLRP3 and its downstream pro-inflammatory signals- caspase-1, interleukin (IL)-1β and IL-18. Blockade of LOX-1 or NLRP3 inflammasome with specific siRNAs reduced xanthine oxidase-induced foam cell formation, ROS generation and activation of NLRP3 and downstream signals. Xanthine oxidase induces foam cell formation in large part through activation of LOX-1 - NLRP3 pathway in both VSMCs and THP-1 cells, but uric acid-induced foam cell formation is exclusively through CD36 pathway. Further, LOX-1 activation is upstream of NLRP3 activation. Graphical Abstract Steps in the formation of foam cells in response to xanthine oxidase and uric acid. Xanthine oxidase stimulates LOX-1 expression on the cell membrane of macrophages and vascular smooth muscle cells (VSMCs) and increases generation of ROS, which activate NLRP3 inflammasome and downstream pro-inflammatory mediators such as Caspase-1, IL-1β and IL-18. Xanthine oxidase also induces CD36 expression. Activation of both LOX-1 and CD36 (LOX-1> > CD36) participates in the transformation of macrophages and VSMCs into foam cells. Uric acid formed from xanthine-xanthine oxidase interaction stimulates CD36 expression and triggers foam cell formation independent of NLRP3 activation.
Bone augmentation using a highly porous PLGA/β-TCP scaffold containing fibroblast growth factor-2.
Yoshida, T; Miyaji, H; Otani, K; Inoue, K; Nakane, K; Nishimura, H; Ibara, A; Shimada, A; Ogawa, K; Nishida, E; Sugaya, T; Sun, L; Fugetsu, B; Kawanami, M
2015-04-01
Beta-tricalcium phosphate (β-TCP), a bio-absorbable ceramic, facilitates bone conductivity. We constructed a highly porous three-dimensional scaffold, using β-TCP, for bone tissue engineering and coated it with co-poly lactic acid/glycolic acid (PLGA) to improve the mechanical strength and biological performance. The aim of this study was to examine the effect of implantation of the PLGA/β-TCP scaffold loaded with fibroblast growth factor-2 (FGF-2) on bone augmentation. The β-TCP scaffold was fabricated by the replica method using polyurethane foam, then coated with PLGA. The PLGA/β-TCP scaffold was characterized by scanning electron miscroscopy (SEM), transmission electron microscopy (TEM), X-ray diffraction, compressive testing, cell culture and a subcutaneous implant test. Subsequently, a bone-forming test was performed using 52 rats. The β-TCP scaffold, PLGA-coated scaffold, and β-TCP and PLGA-coated scaffolds loaded with FGF-2, were implanted into rat cranial bone. Histological observations were made at 10 and 35 d postsurgery. SEM and TEM observations showed a thin PLGA layer on the β-TCP particles after coating. High porosity (> 90%) of the scaffold was exhibited after PLGA coating, and the compressive strength of the PLGA/β-TCP scaffold was six-fold greater than that of the noncoated scaffold. Good biocompatibility of the PLGA/β-TCP scaffold was found in the culture and implant tests. Histological samples obtained following implantation of PLGA/β-TCP scaffold loaded with FGF-2 showed significant bone augmentation. The PLGA coating improved the mechanical strength of β-TCP scaffolds while maintaining high porosity and tissue compatibility. PLGA/β-TCP scaffolds, in combination with FGF-2, are bioeffective for bone augmentation. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Foam suppression in overloaded manure-based biogas reactors using antifoaming agents.
Kougias, P G; Boe, K; Tsapekos, P; Angelidaki, I
2014-02-01
Foam control is an imperative need in biogas plants, as foaming is a major operational problem. In the present study, the effect of oils (rapeseed oil, oleic acid, and octanoic acid) and tributylphosphate on foam reduction and process performance in batch and continuous manure-based biogas reactors was investigated. The compounds were tested in dosages of 0.05%, 0.1% and 0.5% v/vfeed. The results showed that rapeseed oil was most efficient to suppress foam at the dosage of 0.05% and 0.1% v/vfeed, while octanoic acid was most efficient to suppress foam at dosage of 0.5% v/vfeed. Moreover, the addition of rapeseed oil also increased methane yield. In contrast, tributylphosphate, which was very efficient antifoam, was found to be inhibitory to the biogas process. Copyright © 2013 Elsevier Ltd. All rights reserved.
Amaranth proteins foaming properties: Film rheology and foam stability - Part 2.
Bolontrade, Agustín J; Scilingo, Adriana A; Añón, María C
2016-05-01
In this work the influence of pH and ionic strength on the stability of foams prepared with amaranth protein isolate was analyzed. The behaviour observed was related to the physico-chemical and structural changes undergone by amaranth protein as a result of those treatments. The results obtained show that foams prepared at acidic pH were more stable than the corresponding to alkaline pH. At pH 2.0 the foams presented higher times and more volumes of drainage. This behaviour is consistent with the characteristics of the interfacial film, which showed a higher viscoelasticity and a greater flexibility at acidic pH than alkaline pH value, which in turn increased by increasing the concentration of proteins in the foaming solution. It is also important to note that the presence of insoluble protein is not necessarily detrimental to the properties of the foam. Detected changes in the characteristics of the interfacial film as in the foam stability have been attributed to the increased unfolding, greater flexibility and net charge of amaranth proteins at acidic conditions. Copyright © 2014 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Cong; Luo, Xiaolan; Li, Tao
2014-01-01
Environmentally friendly biopolyols have been produced with crude glycerol as the sole feedstock using a one-pot thermochemical conversion process without the addition of extra catalysts and reagents. Structural features of these biopolyols were characterized by rheology analysis. Rigid polyurethane (PU) foams were obtained from these crude glycerol-based biopolyols and the foaming mechanism was explored. Investigations revealed that partial carbonyl groups hydrogen-bonded with NeH were replaced by aromatic rings after the introduction of branched fatty acid ester chains in the “urea rich” phase, and that distinct microphases had formed in the foams. Studies showed that branched fatty acid ester chains inmore » the biopolyols played an important role in reducing the degree of microphase separation and stabilizing bubbles during foaming processes. PU foams with thermal conductivity comparable to commercial products made from petroleum-based polyols were obtained. These studies show the potential for development of PU foams based on crude glycerol, a renewable resource.« less
NASA Astrophysics Data System (ADS)
Elvistia Firdaus, Flora
2016-04-01
The polyurethanes (PUs) foam were made from vegetable oil; a soybean based polyol. The foams were categorized into flexible and semi rigid. This research is manufacturally designed polyurethane foams by a process requiring the reaction of mixture of 2, 4- and 2, 6-Toluene di Isocyanate isomers, soy polyol in the presence of other ingredients. The objective of this work was to functionalized soy-polyol using phosporic acid catalyst and chain extender, study their collaborative reaction in producing ultimate property of PU foam. Correlates the foam morphology images in accordance to mechanical properties of foams.
In vivo performance of novel soybean/gelatin-based bioactive and injectable hydroxyapatite foams
Kovtun, Anna; Goeckelmann, Melanie J.; Niclas, Antje A.; Montufar, Edgar B.; Ginebra, Maria-Pau; Planell, Josep A.; Santin, Matteo; Ignatius, Anita
2015-01-01
Major limitations of calcium phosphate cements (CPCs) are their relatively slow degradation rate and the lack of macropores allowing the ingrowth of bone tissue. The development of self-setting cement foams has been proposed as a suitable strategy to overcome these limitations. In previous work we developed a gelatine-based hydroxyapatite foam (G-foam), which exhibited good injectability and cohesion, interconnected porosity and good biocompatibility in vitro. In the present study we evaluated the in vivo performance of the G-foam. Furthermore, we investigated whether enrichment of the foam with soybean extract (SG-foam) increased its bioactivity. G-foam, SG-foam and non-foamed CPC were implanted in a critical-size bone defect in the distal femoral condyle of New Zealand white rabbits. Bone formation and degradation of the materials were investigated after 4, 12 and 20 weeks using histological and biomechanical methods. The foams maintained their macroporosity after injection and setting in vivo. Compared to non-foamed CPC, cellular degradation of the foams was considerably increased and accompanied by new bone formation. The additional functionalization with soybean extract in the SG-foam slightly reduced the degradation rate and positively influenced bone formation in the defect. Furthermore, both foams exhibited excellent biocompatibility, implying that these novel materials may be promising for clinical application in non-loaded bone defects. PMID:25448348
In vivo performance of novel soybean/gelatin-based bioactive and injectable hydroxyapatite foams.
Kovtun, Anna; Goeckelmann, Melanie J; Niclas, Antje A; Montufar, Edgar B; Ginebra, Maria-Pau; Planell, Josep A; Santin, Matteo; Ignatius, Anita
2015-01-01
Major limitations of calcium phosphate cements (CPCs) are their relatively slow degradation rate and the lack of macropores allowing the ingrowth of bone tissue. The development of self-setting cement foams has been proposed as a suitable strategy to overcome these limitations. In previous work we developed a gelatine-based hydroxyapatite foam (G-foam), which exhibited good injectability and cohesion, interconnected porosity and good biocompatibility in vitro. In the present study we evaluated the in vivo performance of the G-foam. Furthermore, we investigated whether enrichment of the foam with soybean extract (SG-foam) increased its bioactivity. G-foam, SG-foam and non-foamed CPC were implanted in a critical-size bone defect in the distal femoral condyle of New Zealand white rabbits. Bone formation and degradation of the materials were investigated after 4, 12 and 20weeks using histological and biomechanical methods. The foams maintained their macroporosity after injection and setting in vivo. Compared to non-foamed CPC, cellular degradation of the foams was considerably increased and accompanied by new bone formation. The additional functionalization with soybean extract in the SG-foam slightly reduced the degradation rate and positively influenced bone formation in the defect. Furthermore, both foams exhibited excellent biocompatibility, implying that these novel materials may be promising for clinical application in non-loaded bone defects. Copyright © 2014 Acta Materialia Inc. All rights reserved.
A "by-productless" cellulose foaming agent for use in imidazolium ionic liquids.
Scott, Janet L; Unali, Gianfranco; Perosa, Alvise
2011-03-14
Cellulose foams, or sponges, are produced from solutions in ionic liquids by the aqueous acid mediated decomposition of 1-alkyl-3-methylimidazolium-2-carboxylates, where the alkyl group and acid may be selected such that the by-product is the ionic liquid solvent: a by-productless foaming.
Lee, J W; Cha, D K; Kim, I; Son, A; Ahn, K H
2008-02-01
Fatty acid methyl ester (FAME) technology was evaluated as a monitoring tool for quantification of Gordonia amarae in activated sludge systems. The fatty acid, 19:1 alcohol, which was identified as a unique fatty acid in G. amarae was not only confirmed to be present in foaming plant samples, but the quantity of the signature peak correlated closely with the degree of foaming. Foaming potential experiment provided a range of critical foaming levels that corresponded to G. amarae population. This range of critical Gordonia levels was correlated to the threshold signature FAME amount. Six full-scale wastewater treatment plants were selected based on a survey to participate in our full-scale study to evaluate the potential application of the FAME technique as the Gordonia monitoring tool. Greater amounts of signature FAME were extracted from the mixed liquor samples obtained from treatment plants experiencing Gordonia foaming problems. The amounts of signature FAME correlated well with the conventional filamentous counting technique. These results demonstrated that the relative abundance of the signature FAMEs can be used to quantitatively monitor the abundance of foam-causing microorganism in activated sludge.
Solomon, James A; Tyring, Stephen; Staedtler, Gerald; Sand, Meike; Nkulikiyinka, Richard; Shakery, Kaweh
2016-09-01
Papulopustular rosacea (PPR) is characterized by centrofacial papules and pustules commonly associated with erythema. To compare investigator-reported efficacy outcomes for azelaic acid (AzA) foam 15% versus vehicle foam in PPR, a randomized, vehicle-controlled, double-blind phase 3 clinical trial was conducted at 48 US sites. Participants received AzA foam or vehicle foam for 12 weeks. Secondary efficacy outcomes included change in inflammatory lesion count (ILC), therapeutic response rate according to investigator global assessment (IGA), and change in erythema rating. This study was comprised of 961 participants with PPR. The results support the therapeutic superiority of AzA foam over vehicle foam.
Production and Precipitation Hardening of Beta-Type Ti-35Nb-10Cu Alloy Foam for Implant Applications
NASA Astrophysics Data System (ADS)
Mutlu, Ilven; Yeniyol, Sinem; Oktay, Enver
2016-04-01
In this study, beta-type Ti-35Nb-10Cu alloy foams were produced by powder metallurgy method for dental implant applications. 35% Nb was added to stabilize the beta-Ti phase with low Young's modulus. Cu addition enhanced sinterability and gave precipitation hardening capacity to the alloy. Sintered specimens were precipitation hardened in order to enhance the mechanical properties. Electrochemical corrosion behavior of the specimens was examined by electrochemical impedance spectroscopy in artificial saliva. Electrochemical impedance spectroscopy results indicated that the oxide film on the surface of foam is a bi-layer structure consisting of outer porous layer and inner barrier layer. Impedance values of barrier layer were higher than porous layer. Corrosion resistance of specimens decreased at high fluoride concentrations and at low pH of artificial saliva. Corrosion resistance of alloys was slightly decreased with aging. Mechanical properties, microstructure, and surface roughness of the specimens were also examined.
Injectable silk foams for the treatment of cervical insufficiency
NASA Astrophysics Data System (ADS)
Fournier, Eric P.
Preterm birth is the leading cause of neonatal mortality, resulting in over 4,000 deaths each year. A significant risk factor for preterm birth is cervical insufficiency, the weakening and subsequent deformation of cervical tissue. Cervical insufficiency is both detectable and treatable but current treatments are lacking. The most common approach requires multiple invasive procedures. This work investigates the injection of silk foams, a minimally-invasive method for supporting cervical tissue. Silk offers many advantages for use as a biomaterial including strength, versatility, and biocompatibility. Injectable silk foams will minimize patient discomfort while also providing more targeted and personalized treatment. A battery of mechanical testing was undertaken to determine silk foam response under physiologically relevant loading and environmental conditions. Mechanical testing was paired with analysis of foam morphology and structure that illustrated the effects of injection on pore geometry and size. Biological response to silk foams was evaluated using an in vitro degradation study and subcutaneous in vivo implantation in a mouse model. Results showed that foams exceeded the mechanical requirements for stiffening cervical tissue, although the current injection process limits foam size. Injection was shown to cause measurable but localized foam deformation. This work indicates that silk foams are a feasible treatment option for cervical insufficiency but challenges remain with foam delivery.
The foaming properties of camel and bovine whey: The impact of pH and heat treatment.
Lajnaf, Roua; Picart-Palmade, Laetitia; Cases, Eliane; Attia, Hamadi; Marchesseau, Sylvie; Ayadi, M A
2018-02-01
The effect of heat treatment (70°C or 90°C for 30min) on the foaming and interfacial properties of acid and sweet whey obtained from bovine and camel fresh milk was examined. The maximum foamability and foam stability were observed for acid whey when compared to sweet whey for both milks, with higher values for the camel whey. This behavior for acid whey was explained by the proximity of the pI of whey protein (4.9-5.2), where proteins were found to carry the lowest negative charge as confirmed by the zeta potential measurements. Interfacial properties of acid camel whey and acid bovine whey were preserved at air water interface even after a heat treatment at 90°C. These results confirmed the pronounced foaming and interfacial properties of acid camel whey, even if acid and sweet bovine whey exhibited the highest viscoelastic modulus after heating. Copyright © 2017 Elsevier Ltd. All rights reserved.
Synthesis of palm oil fatty acid as foaming agent for firefighting application
NASA Astrophysics Data System (ADS)
Rivai, M.; Hambali, E.; Suryani, A.; Fitria, R.; Firmansyah, S.; Pradesi, J.
2017-05-01
Many factors including natural factor, human carelessness, new land clearance or agricultural burning/act of vandalism and ground fire are suspected as the causes of forest fire. Foam, which cools the fire down, covers the burning material/fuel, and avoids contact between burning materials with oxygen, is an effective material used to fight large-scale fires. For this purpose, surfactant which can facilitate foam formation and inhibit the spread of smoke is required. This study was aimed at producing prototype product of foaming agent from palm oil and its formulation as a fire fighting material. Before the formulation stage, the foaming agent was resulted from saponification process of oleic, lauric, and palmitic acids by using NaOH and KOH alkaline. Foam stability was used as the main indicator of foaming agent. Results showed that potassium palmitate had the highest foam stability of 82% until the 3rd day. The best potassium palmitate concentration was 7%.
Divac, Marija; Stawarczyk, Bogna; Sahrmann, Philipp; Attin, Thomas; Schmidlin, Patrick R
2013-01-01
To assess the primary stability of a hybrid self-tapping implant and a cylindric non-self-tapping implant in an in vitro test model using polyurethane foam. Eighty standardized blocks of cellular rigid polyurethane foam, 2 cm long and 1 cm wide, with different thicknesses of 2, 4, 6, and 9 mm (n = 10 per group) were cut. Two implant systems--a hybrid self-tapping (Tapered Effect [TE], Straumann) and a cylindric non-self-tapping (Standard Plus [SP] Wide Neck, Straumann) were placed in the block specimens. Subsequently, resonance frequency analysis (RFA) was performed. The RFA measurements were made in triplicate on four aspects of each implant (mesial, distal, buccal, and oral), and the mean RFA value was calculated. Subsequently, the tensile load of the implants was determined by pull-out tests. The data were analyzed using one-way and two-way analysis of variance followed by a post hoc Scheffe test and a t test (α = .05). Additionally, the simple linear correlation between the RFA and tensile load values was evaluated. No statistically significant differences were found between TE and SP in terms of RFA at different bone thicknesses. Starting from a bone thickness of 4 mm, TE implants showed significantly higher tensile load compared to SP implants (P = .016 to .040). A correlation was found between the RFA measurements and tensile load. Mechanically stable placement is possible with TE and SP implants in a trabecular bone model. RFA and tensile load increased with greater bone thickness.
A polymer foam conduit seeded with Schwann cells promotes guided peripheral nerve regeneration.
Hadlock, T; Sundback, C; Hunter, D; Cheney, M; Vacanti, J P
2000-04-01
Alternatives to autografts have long been sought for use in bridging neural gaps. Many entubulation materials have been studied, although with generally disappointing results in comparison with autografts. The purpose of this study was to design a more effective neural guidance conduit, to introduce Schwann cells into the conduit, and to determine regenerative capability through it in an in vivo model. A novel, fully biodegradable polymer conduit was designed and fabricated for use in peripheral nerve repair, which approximates the macro- and microarchitecture of native peripheral nerves. It comprised a series of longitudinally aligned channels, with diameters ranging from 60 to 550 microns. The lumenal surfaces promoted the adherence of Schwann cells, whose presence is known to play a key role in nerve regeneration. This unique channel architecture increased the surface area available for Schwann cell adherence up to five-fold over that available through a simple hollow conduit. The conduit was composed of a high-molecular-weight copolymer of lactic and glycolic acids (PLGA) (MW 130,000) in an 85:15 monomer ratio. A novel foam-processing technique, employing low-pressure injection molding, was used to create highly porous conduits (approximately 90% pore volume) with continuous longitudinal channels. Using this technique, conduits were constructed containing 1, 5, 16, 45, or more longitudinally aligned channels. Prior to cellular seeding of these conduits, the foams were prewet with 50% ethanol, flushed with physiologic saline, and coated with laminin solution (10 microg/mL). A Schwann cell suspension was dynamically introduced into these processed foams at a concentration of 5 X 10(5) cells/mL, using a simple bioreactor flow loop. In vivo regeneration studies were carried out in which cell-laden five-channel polymer conduits (individual channel ID 500 microm, total conduit OD 2.3 mm) were implanted across a 7-mm gap in the rat sciatic nerve (n = 4), and midgraft axonal regeneration compared with autografts (n = 6). At 6 weeks, axonal regeneration was observed in the midconduit region of all five channels in each experimental animal. The cross-sectional area comprising axons relative to the open conduit cross sectional area (mean 26.3%, SD 10. 1%) compared favorably with autografts (mean 23.8%, SD 3.6%). Our methodology can be used to create polymer foam conduits containing longitudinally aligned channels, to introduce Schwann cells into them, and to implant them into surgically created neural defects. These conduits provide an environment permissive to axonal regeneration. Furthermore, this polymer foam-processing method and unique channeled architecture allows the introduction of neurotrophic factors into the conduit in a controlled fashion. Deposition of different factors into distinct regions within the conduit may be possible to promote more precisely guided neural regeneration.
Sugiura, Yuki; Tsuru, Kanji; Ishikawa, Kunio
2017-08-01
Carbonate apatite (CO 3 Ap) foam with an interconnected porous structure is highly attractive as a scaffold for bone replacement. In this study, arbitrarily shaped CO 3 Ap foam was formed from α-tricalcium phosphate (α-TCP) foam granules via a two-step process involving treatment with acidic calcium phosphate solution followed by hydrothermal treatment with NaHCO 3 . The treatment with acidic calcium phosphate solution, which is key to fabricating arbitrarily shaped CO 3 Ap foam, enables dicalcium hydrogen phosphate dihydrate (DCPD) crystals to form on the α-TCP foam granules. The generated DCPD crystals cause the α-TCP granules to interlock with each other, inducing an α-TCP/DCPD foam. The interlocking structure containing DCPD crystals can survive hydrothermal treatment with NaHCO 3 . The arbitrarily shaped CO 3 Ap foam was fabricated from the α-TCP/DCPD foam via hydrothermal treatment at 200 °C for 24 h in the presence of a large amount of NaHCO 3 .
NASA Technical Reports Server (NTRS)
Sawko, Paul M. (Inventor); Riccitiello, Salvatore R. (Inventor); Hamermesh, Charles L. (Inventor)
1980-01-01
Flame and temperature resistant polyimide foams are prepared by the reaction of an aromatic dianhydride, e.g., pyromellitic dianhydride, with an aromatic polyisocyanate, e.g., polymethylene polyphenylisocyanate (PAPI) in the presence of an inorganic acid and a lower molecular weight alcohol, e.g., dilute sulfuric acid or phosphoric acid and furfuryl alcohol. The exothermic reaction between the acid and the alcohol provides the heat necessary for the other reactants to polymerize without the application of any external heat. Such mixtures, therefore, are ideally suited for in situ foam formation, especially where the application of heat is not practical or possible.
Wagstaff, Marcus James Dermot; Driver, Sara; Coghlan, Patrick; Greenwood, John Edward
2014-01-01
The objectives of the study were (1) to look for any local, clinically apparent response, within and around a debrided wound, to a novel biocompatible polyurethane foam during repeated, short-term implantation, and (2) to assess the material's efficacy as a negative pressure wound therapy (NPWT) interface compared with a widely used, commercially available foam. Twenty pressure ulcers in 18 patients underwent surgical debridement, then randomization to receive novel treatment or control foam as the wound interface for NPWT. Dressing changes every 2-3 days allowed qualitative wound assessment and quantitative measurement to compare outcomes. No adverse reaction was observed in any patient receiving the new foam. The new "novel foam" performed as a NPWT interface as effectively as the control "standard foam." In deep wounds, the new foam was easier to remove, fragmented less, and showed less retention than the control foam. No marginal in-growth occurred, making removal less traumatic and reducing bleeding from cavity wall granulations. The results support previous large animal studies, and independent ISO10993 testing, that the new foam is safe and biocompatible. Its efficacy as an NPWT interface, nontraumatic removal with low fragmentation and retention rate, favors the new material, especially in deep cavity wounds. © 2014 by the Wound Healing Society.
Polyurethane Implants in 2-Stage Breast Reconstruction: 9-Year Clinical Experience.
Pompei, Stefano; Arelli, Floriana; Labardi, Lara; Marcasciano, Fabio; Evangelidou, Dora; Ferrante, Gianluigi
2017-02-01
Capsular contracture (CC) is a major complication of breast surgery with smooth and textured implants. Polyurethane (PU) foam-coated breast implants were developed to decrease the incidence of CC. The authors determined the incidence of CC following 2-stage breast reconstruction using PU foam-covered implants, with and without radiation therapy. The records of 92 patients who received 115 PU implants were retrospectively reviewed. The rates of CC over time were compared for irradiated and nonirradiated groups with a Kaplan-Meier analysis and log-rank test. CC rates also were analyzed with respect to age. The median follow-up time for patients was 103.3 months. Nine patients experienced unilateral Baker grade III or IV fibrous CC, including 6 patients from the irradiated group and 3 patients from the nonirradiated group. The overall cumulative incidence of CC at 9 years was 8.1%. In the irradiated and nonirradiated groups, the 9-year cumulative incidence was 10.7% and 5.5%, respectively. CC occurred within 3 years in the irradiated group and within 7 years in the nonirradiated group. The incidence of CC appeared to be higher among younger patients. Radiation therapy increases the risk of high-grade CC with textured or smooth implants. PU implants are associated with a much lower cumulative incidence of CC following 2-stage breast reconstruction, even when radiotherapy is performed. LEVEL OF EVIDENCE 3. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.
Carbon foam/hydroxyapatite coating for carbon/carbon composites: Microstructure and biocompatibility
NASA Astrophysics Data System (ADS)
Zhang, Leilei; Li, Hejun; Li, Kezhi; Zhang, Shouyang; Lu, Jinhua; Li, Wei; Cao, Sheng; Wang, Bin
2013-12-01
To improve the surface biocompatibility of carbon/carbon composites, a carbon foam/hydroxyapatite coating was applied using a combination method of slurry procedure and ultrasound-assisted electrochemical deposition procedure. The morphology, microstructure and chemical composition of the coating were investigated by scanning electron microscopy, energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy, Raman spectroscopy and X-ray diffraction. The biocompatibility of the carbon foam/hydroxyapatite coating was investigated by osteoblast-like MG63 cell culture tests. The results showed that the carbon foam could provide a large number of pores on the surface of carbon/carbon composites. The hydroxyapatite crystals could infiltrate into the pores and form the carbon foam/hydroxyapatite coating. The coating covered the carbon/carbon composites fully and uniformly with slice morphology. The cell response tests showed that the MG63 cells on carbon foam/hydroxyapatite coating had a better cell adhesion and cell proliferation than those on uncoated carbon/carbon composites. The carbon foam/hydroxyapatite coatings were cytocompatible and were beneficial to improve the biocompatibility. The approach presented here may be exploited for fabrication of carbon/carbon composite implant surfaces.
Degradable and porous Fe-Mn-C alloy for biomaterials candidate
NASA Astrophysics Data System (ADS)
Pratesa, Yudha; Harjanto, Sri; Larasati, Almira; Suharno, Bambang; Ariati, Myrna
2018-02-01
Nowadays, degradable implants attract attention to be developed because it can improve the quality of life of patients. The degradable implant is expected to degrade easily in the body until the bone healing process already achieved. However, there is limited material that could be used as a degradable implant, polymer, magnesium, and iron. In the previous study, Fe-Mn-C alloys had succesfully produced austenitic phase. However, the weakness of the alloy is degradation rate of materials was considered below the expectation. This study aimed to produce porous Fe-Mn-C materials to improve degradation rate and reduce the density of alloy without losing it non-magnetic properties. Potassium carbonate (K2CO3) were chosen as filler material to produce foam structure by sintering and dissolution process. Multisteps sintering process under argon gas environment was performed to generate austenite phase. The product showed an increment of the degradation rate of the foamed Fe-Mn-C alloy compared with the solid Fe-Mn-C alloy without losing the Austenitic Structure
NASA Astrophysics Data System (ADS)
Rocher, Sandrine; Botrel, Ronan; Durut, Frédéric; Chicanne, Cédric; Theobald, Marc; Vignal, Vincent
2018-02-01
The goal of this work is to realize metallic foams synthesized by contact glow discharge electrolysis with specific characteristics. In this paper, we show the results of our studies, consisting in investigating parameters that influence the foams characteristics. Thus, the morphology of metallic foams is examined through scanning electron microscopy (SEM) observations with the acid nature. Moreover, the evolution of the mass and the volume of metallic foams with two experimental parameters (overvoltage and gold concentration) is also investigated. The acid nature affects the foams microscopic structure highlighted by the SEM observations, but for now no valid explanation to this behaviour was found. We prove that the mass deposited on the electrode is dependent on the ionic salt concentration, whereas the overvoltage only affects the foam overall density. Contribution to the topical issue "Plasma Sources and Plasma Processes (PSPP)", edited by Luis Lemos Alves, Thierry Belmonte and Tiberiu Minea.
Antifoaming effect of chemical compounds in manure biogas reactors.
Kougias, P G; Tsapekos, P; Boe, K; Angelidaki, I
2013-10-15
A precise and efficient antifoaming control strategy in bioprocesses is a challenging task as foaming is a very complex phenomenon. Nevertheless, foam control is necessary, as foam is a major operational problem in biogas reactors. In the present study, the effect of 14 chemical compounds on foam reduction was evaluated at concentration of 0.05%, 0.1% and 0.5% v/v(sample), in raw and digested manure. Moreover, two antifoam injection methods were compared for foam reduction efficiency. Natural oils (rapeseed and sunflower oil), fatty acids (oleic, octanoic and derivative of natural fatty acids), siloxanes (polydimethylsiloxane) and ester (tributylphosphate) were found to be the most efficient compounds to suppress foam. The efficiency of antifoamers was dependant on their physicochemical properties and greatly correlated to their chemical characteristics for dissolving foam. The antifoamers were more efficient in reducing foam when added directly into the liquid phase rather than added in the headspace of the reactor. Copyright © 2013 Elsevier Ltd. All rights reserved.
Foaming and emulsifying properties of porcine red cell protein concentrate.
Salvador, P; Saguer, E; Parés, D; Carretero, C; Toldrà, M
2010-08-01
This work focuses on studying the effects of pH (7.0 and 4.5) and protein concentration on the foaming and emulsifying properties of fresh (F) and spray-dried (SD) porcine red cell protein (RCP) concentrates in order to evaluate the proper use of this blood protein as a functional food ingredient. Also, protein solubility is measured through the pH range from 3.0 to 8.0. In each case, all concentrates show a high solubility, although this is significantly affected by pH. Spray drying slightly reduces the solubility at mild acid and neutral conditions. The foaming capacity is found to be dependent on pH as well as on the drying treatment. SD-RCP concentrates show better foaming capacity than F-RCP. The minimum protein concentration required to attain the highest foaming capacity is found under acid pH for the spray-dried concentrates. Although F-RCP shows low foam stability at acid and neutral pH, spray drying and protein content enhance the stability of foams. Emulsifying properties show dependence on pH as well as on protein content. Furthermore, spray drying affects the emulsifying properties but in different ways, depending on pH and protein concentration.
Chen, Fu-xin; Wang, Lian-kai
2015-02-01
The formation of macrophage-derived foam cells is a typical feature of atherosclerosis (AS). Reverse cholesterol efflux (RCT) is one of important factors for the formation of macrophage foam cells. In this study, macrophage form cells were induced by oxidized low density lipoprotein (ox-LDL) and then treated with different concentrations of ferulic acid, so as to observe the effect of ferulic acid on the intracellular lipid metabolism in the ox-LDL-induced macrophage foam cell formation, the cholesterol efflux and the mRNA expression and protein levels of ATP binding cassette transporter A1 (ABCA1) and ATP binding cassette transporter G1 (ABCG1) that mediate cholesterol efflux, and discuss the potential mechanism of ferulic acid in resisting AS. According to the findings, compared with the control group, the ox-LDL-treated group showed significant increase in intracellular lipid content, especially for the cholesterol content; whereas the intracellular lipid accumulation markedly decreased, after the treatment with ferulic acid. The data also demonstrated that the mRNA and protein expressions of ABCA1 and ABCG1 significantly increased after macrophage foam cells were treated with different concentrations of ferulic acid. In summary, ferulic acid may show the anti-atherosclerosis effect by increasing the surface ABCA1 and ABCG1 expressions of macrophage form cells and promoting cholesterol efflux.
The Efficacy and Safety of Azelaic Acid 15% Foam in the Treatment of Truncal Acne Vulgaris.
Hoffman, Lauren K; Del Rosso, James Q; Kircik, Leon H
2017-06-01
INTRODUCTION: Truncal acne is often associated with facial acne, but there are fewer options for an effective topical treatment on the trunk. Given the advent of foam formulations with enhanced percutaneous absorption and convenient application due to easy spreadability on skin, the previously held idea that effective treatment of truncal acne requires oral treatment is challenged. Azelaic acid cream has been previously approved for acne vulgaris, thus azelaic acid foam may be a viable treatment option for truncal acne.
STUDY DESIGN: A single-center, open label pilot study was conducted to investigate the efficacy and safety of azelaic acid 15% foam as a treatment modality for moderate truncal acne. Use for facial acne was also allowed and monitored during the study.
RESULTS: Twice-daily application of azelaic acid 15% foam to affected areas resulted in a 1-grade reduction in truncal investigator global assessment (IGA) scores in nearly all patients (16/18). Eight out of 18 patients (44%) were rated as Clear or Almost Clear in the trunk by the end of the study. There were also improvements in facial IGA scores; 9 of 18 patients (50%) exhibited a 1-grade improvement in IGA scores and 11 of 18 were Clear or Almost Clear by the end of the study. A significant reduction in lesion counts was found throughout the study and the medication was well tolerated.
CONCUSION: Azelaic acid 15% foam was effective in treating moderate truncal acne and facial acne in this pilot study. Given the efficacy and convenience of the foam vehicle, azelaic acid may be considered as a viable option for treatment of acne vulgaris, including on the trunk. Further studies are suggested in a larger population of patients, including adult females with acne.
J Drugs Dermatol. 2017;16(6):534-538.
.Karaoğul, Eyyüp; Parlar, Perihan; Parlar, Harun; Alma, M Hakkı
2016-01-01
The main aim of this study was to enrich glycyrrhizic acid ammonium salt known as one of the main compounds of licorice roots (Glycyrrhiza glabra L.) by isoelectric focused adsorptive bubble separation technique with different foaming agents. In the experiments, four bubble separation parameters were used with β-lactoglobulin, albumin bovine, and starch (soluble) preferred as foaming agents and without additives. The enrichment of glycyrrhizic acid ammonium salt into the foam was influenced by different additive substances. The results showed that highest enrichment values were obtained from β-lactoglobulin as much as 368.3 times. The lowest enrichment values (5.9 times) were determined for the application without additive. After enrichment, each experiment of glycyrrhizic acid ammonium salt confirmed that these substances could be quantitatively enriched into the collection vessel with isoelectric focused adsorptive bubble separation technique. The transfer of glycyrrhizic acid ammonium salt into the foam from standard solution in the presence of additive was more efficient than aqueous licorice extract.
Karaoğul, Eyyüp; Parlar, Perihan; Parlar, Harun; Alma, M. Hakkı
2016-01-01
The main aim of this study was to enrich glycyrrhizic acid ammonium salt known as one of the main compounds of licorice roots (Glycyrrhiza glabra L.) by isoelectric focused adsorptive bubble separation technique with different foaming agents. In the experiments, four bubble separation parameters were used with β-lactoglobulin, albumin bovine, and starch (soluble) preferred as foaming agents and without additives. The enrichment of glycyrrhizic acid ammonium salt into the foam was influenced by different additive substances. The results showed that highest enrichment values were obtained from β-lactoglobulin as much as 368.3 times. The lowest enrichment values (5.9 times) were determined for the application without additive. After enrichment, each experiment of glycyrrhizic acid ammonium salt confirmed that these substances could be quantitatively enriched into the collection vessel with isoelectric focused adsorptive bubble separation technique. The transfer of glycyrrhizic acid ammonium salt into the foam from standard solution in the presence of additive was more efficient than aqueous licorice extract. PMID:26949562
Effect of water on foaming properties of diglycerol fatty acid ester-oil systems.
Shrestha, Lok Kumar; Shrestha, Rekha Goswami; Solans, Conxita; Aramaki, Kenji
2007-06-19
We have studied the effect of added water on the nonaqueous foaming properties of diglycerol fatty acid ester nonionic surfactant systems. Diglycerol monomyristate (designated as DGM) could not foam in nonpolar oils squalane and hexadecane at normal room temperature. Nevertheless, addition of a small amount of water induces a dramatic change in foaming properties. Both the foamability and foam stability increases with the amount of added water within the studied concentration range. Phase behavior study showed that in the dilute regions there is dispersion of solid surfactant in the aforementioned oils in the DGM systems. The particle size of the dispersed solid phase was found to be several tens of microns in the water free system, and hence it tends to coagulate and precipitate. In the case of shorter alkyl chain length, diglycerol monolaurate (DGL) surfactant-oil systems, dispersion of lamellar liquid crystal (Lalpha) is observed at room temperature, and the poor foaming properties were attributed to the large particle size of the liquid crystal. In both the DGL and DGM-oil systems, we observed a tendency of the particle size to decrease with the increasing concentration of added water. At higher temperature, the solid surfactant transforms to lamellar liquid crystal phase, and foaming is improved in the DGM/squalane system. Foams are stable for several minutes. Judging from the foaming test and particle size distribution data it can be concluded that the poor foaming in the diglycerol fatty acid esters-oil systems may possibly be due to bigger particle size, which causes precipitation. Addition of water results in the dispersion of smaller particles and improves the foaming behavior.
Rodriguez, Renata P; Zaiat, Marcelo
2011-04-01
This paper analyzes the influence of carbon source and inoculum origin on the dynamics of biomass adhesion to an inert support in anaerobic reactors fed with acid mine drainage. Formic acid, lactic acid and ethanol were used as carbon sources. Two different inocula were evaluated: one taken from an UASB reactor and other from the sediment of a uranium mine. The values of average colonization rates and the maximum biomass concentration (C(max)) were inversely proportional to the number of carbon atoms in each substrate. The highest C(max) value (0.35 g TVS g(-1) foam) was observed with formic acid and anaerobic sludge as inoculum. Maximum colonization rates (v(max)) were strongly influenced by the type of inoculum when ethanol and lactic acid were used. For both carbon sources, the use of mine sediment as inoculum resulted in a v(max) of 0.013 g TVS g(-1) foam day(-1), whereas 0.024 g TVS g(-1) foam day(-1) was achieved with anaerobic sludge. Copyright © 2011 Elsevier Ltd. All rights reserved.
Carpena, Nathaniel T; Abueva, Celine D G; Padalhin, Andrew R; Lee, Byong-Taek
2017-10-01
Studies have shown the technological and functional properties of ovomucin (OVN) in the food-agricultural industry. But research has yet to explore its potential as an implantable biomaterial for tissue engineering and regenerative medicine. In this study we isolated OVN from egg white by isoelectric precipitation and fabricated scaffolds with tunable porosity by utilizing its foaming property. Gelatin a known biocompatible material was introduced to stabilize the foams, wherein different ratios of OVN and gelatin had a significant effect on the degree of porosity, pore size and stability of the formed hydrogels. The porous scaffolds were crosslinked with EDC resulting in stable scaffolds with prolonged degradation. Improved cell proliferation and adhesion of rat bone marrow-derived mesenchymal stem cells were observed for OVN containing scaffolds. Although, scaffolds with 75% OVN showed decrease in cell proliferation for L929 fibroblast type of cells. Further biocompatibility assessment as implant material was determined by subcutaneous implantation in rats of selected scaffold. H&E staining showed reasonable vascularization over time and little evidence of severe fibrosis at the implant site. Persistent polarization of classically activated macrophage was not observed, potentially reducing inflammatory response, and showed increased expression of alternatively activated macrophage cells that is favorable for tissue repair. Analysis of IgE levels in rat serum after implantation indicated minimal and resolvable allergic response to the OVN implants. The results demonstrate OVN as an acceptable implant scaffold that could provide new opportunities as an alternative natural biocompatible and functional biomaterial in various biomedical applications. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2107-2117, 2017. © 2016 Wiley Periodicals, Inc.
Synthesis carbon foams prepared from gelatin (CFG) for cadmium ion adsorption
NASA Astrophysics Data System (ADS)
Ulfa, M.; Ulfa, D. K.
2018-01-01
In this paper, carbon foam from gelatin (CFG) was synthesized by acid-catalyzed carbonization of gelatin solution on mild condition by the simple method. Gelatin (Ge) were used as sacrificial template and source of carbon. Sulphuric acid was used as acid catalyst. Carbon foam CFG sample were characterized by scanning electron microscope (SEM), nitrogen adsorption desorption and FTIR for knowing textural and structural properties of the sample. Carbon foam CFG sample demonstrated macro pipes-channel like with pore size that varies between 30-40 μ and surface area m 60-100 m2g-1. The carbon foams CFG sample were tested by using adsorption process for obtained their performance for decreasing Cd(II) ions from aqueous solutions. The adsorption capacities for cadmium was 46.7 mg/g obtained by using adsorbent dose 50 mg, initial concentration 50 ppm, contact time, 3 h; room temperature, stirring rate 150 rpm) which reached equilibrium at 55 min. Adsorption process fits using using Lagergren and Ho and McKay equation and measuring data
Krafft, Tim; Winter, Werner; Wichmann, Manfred; Karl, Matthias
2012-07-01
Alveolar bone quality is considered to be an important prognostic factor in dental implant stability. Although numerous methods have been described, no technique allows for reliable diagnostics. The purpose of this study was to determine if strain measurements on the shaft of a contra angle handpiece during implant bed preparation could be used for the determination of bone quality. Experiments in polyurethane foam and human cadaver bone were conducted to investigate whether strain measurements could be correlated with other diagnostic parameters, such as the surgeon's tactile sensation during drilling, implant insertion torque, implant stability, elastic modulus of bone and bone quality as assessed radiographically. Tests were also performed to determine if strain measurements could be used to distinguish various types of bone. As axial feed and contact pressure during the drilling process could not be standardized under simulated clinical conditions, substantial deviations in the time needed to complete the drilling occurred. Under controlled circumstances using polyurethane foam, this problem could be addressed by a normalization procedure, but great variations occurred in human cadaver bone. As bone quality could not be reliably determined, especially when a cortical layer was present, strain measurements on a contra angle handpiece appears to be inappropriate for this purpose. Copyright © 2011 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Foam and gel methods for the decontamination of metallic surfaces
Nunez, Luis; Kaminski, Michael Donald
2007-01-23
Decontamination of nuclear facilities is necessary to reduce the radiation field during normal operations and decommissioning of complex equipment. In this invention, we discuss gel and foam based diphosphonic acid (HEDPA) chemical solutions that are unique in that these solutions can be applied at room temperature; provide protection to the base metal for continued applications of the equipment; and reduce the final waste form production to one step. The HEDPA gels and foams are formulated with benign chemicals, including various solvents, such as ionic liquids and reducing and complexing agents such as hydroxamic acids, and formaldehyde sulfoxylate. Gel and foam based HEDPA processes allow for decontamination of difficult to reach surfaces that are unmanageable with traditional aqueous process methods. Also, the gel and foam components are optimized to maximize the dissolution rate and assist in the chemical transformation of the gel and foam to a stable waste form.
Organic Geochemistry and Sources of Natural Aquatic Foams
Mills, M.S.; Thurman, E.M.; Ertel, J.; Thorn, K.A.
1996-01-01
Aquatic foams and stream-water samples were collected from two pristine sites for humic substances isolation and characterization. Biomarker compounds identified in foam and stream humic substances included phospholipid fatty acids, steroids, and lignin. Results showed that foams had a 10 to 20 fold greater DOC concentration and were enriched in humic substances (90% by weight of DOC) that showed increased hydrophobicity, aliphatic character, and compositional complexity compared to host stream humic substances (55 to 81% by weight of DOC). Foam humic substances also were enriched in humic acid (36 to 83% by weight) compared to host stream humic substances (10 to 14% by weight). Biomarkers, which contributed less than 5% by weight to the DOC pool, indicated higher plants, bacteria, algae, fungi, and diatoms as DOC sources. It is proposed that aquatic foams may be important media for the concentration and transport of organic substances in the aquatic environment.
Injectable foams for regenerative medicine.
Prieto, Edna M; Page, Jonathan M; Harmata, Andrew J; Guelcher, Scott A
2014-01-01
The design of injectable biomaterials has attracted considerable attention in recent years. Many injectable biomaterials, such as hydrogels and calcium phosphate cements (CPCs), have nanoscale pores that limit the rate of cellular migration and proliferation. While introduction of macroporosity has been suggested to increase cellular infiltration and tissue healing, many conventional methods for generating macropores often require harsh processing conditions that preclude their use in injectable foams. In recent years, processes such as porogen leaching, gas foaming, and emulsion-templating have been adapted to generate macroporosity in injectable CPCs, hydrogels, and hydrophobic polymers. While some of the more mature injectable foam technologies have been evaluated in clinical trials, there are challenges remaining to be addressed, such as the biocompatibility and ultimate fate of the sacrificial phase used to generate pores within the foam after it sets in situ. Furthermore, while implantable scaffolds can be washed extensively to remove undesirable impurities, all of the components required to synthesize injectable foams must be injected into the defect. Thus, every compound in the foam must be biocompatible and noncytotoxic at the concentrations utilized. As future research addresses these critical challenges, injectable macroporous foams are anticipated to have an increasingly significant impact on improving patient outcomes for a number of clinical procedures. © 2013 Wiley Periodicals, Inc.
Injectable Foams for Regenerative Medicine
Prieto, Edna M.; Page, Jonathan M.; Harmata, Andrew J.
2013-01-01
The design of injectable biomaterials has attracted considerable attention in recent years. Many injectable biomaterials, such as hydrogels and calcium phosphate cements, have nanoscale pores that limit the rate of cellular migration and proliferation. While introduction of macroporosity has been suggested to increase cellular infiltration and tissue healing, many conventional methods for generating macropores often require harsh processing conditions that preclude their use in injectable foams. In recent years, processes such as porogen leaching, gas foaming, and emulsion-templating have been adapted to generate macroporosity in injectable calcium phosphate cements, hydrogels, and hydrophobic polymers. While some of the more mature injectable foam technologies have been evaluated in clinical trials, there are challenges remaining to be addressed, such as the biocompatibility and ultimate fate of the sacrificial phase used to generate pores within the foam after it sets in situ. Furthermore, while implantable scaffolds can be washed extensively to remove undesirable impurities, all of the components required to synthesize injectable foams must be injected into the defect. Thus, every compound in the foam must be biocompatible and non-cytotoxic at the concentrations utilized. As future research addresses these critical challenges, injectable macroporous foams are anticipated to have an increasingly significant impact on improving patient outcomes for a number of clinical procedures. PMID:24127230
Carbon Catalyst Synthesis - Sucrose was treated directly with excess sulfuric acid sulfuric acid (9:1 mol/mol, 25°C). A carbon foam (nearly 20 fold increase in bulk volume) was immediately formed. The foam was then washed until no sulfate was dete...
Boyle, Anthony J.; Landsman, Todd L.; Wierzbicki, Mark A.; Nash, Landon D.; Hwang, Wonjun; Miller, Matthew W.; Tuzun, Egemen; Hasan, Sayyeda M.; Maitland, Duncan J.
2015-01-01
Current endovascular therapies for intracranial saccular aneurysms result in high recurrence rates due to poor tissue healing, coil compaction, and aneurysm growth. We propose treatment of saccular aneurysms using shape memory polymer (SMP) foam to improve clinical outcomes. SMP foam-over-wire (FOW) embolization devices were delivered to in vitro and in vivo porcine saccular aneurysm models to evaluate device efficacy, aneurysm occlusion, and acute clotting. FOW devices demonstrated effective delivery and stable implantation in vitro. In vivo porcine aneurysms were successfully occluded using FOW devices with theoretical volume occlusion values greater than 72% and rapid, stable thrombus formation. PMID:26227115
Vrana, Nihal E.; Dupret-Bories, Agnes; Chaubaroux, Christophe; Rieger, Elisabeth; Debry, Christian; Vautier, Dominique; Metz-Boutigue, Marie-Helene; Lavalle, Philippe
2013-01-01
Metallic implants, especially titanium implants, are widely used in clinical applications. Tissue in-growth and integration to these implants in the tissues are important parameters for successful clinical outcomes. In order to improve tissue integration, porous metallic implants have being developed. Open porosity of metallic foams is very advantageous, since the pore areas can be functionalized without compromising the mechanical properties of the whole structure. Here we describe such modifications using porous titanium implants based on titanium microbeads. By using inherent physical properties such as hydrophobicity of titanium, it is possible to obtain hydrophobic pore gradients within microbead based metallic implants and at the same time to have a basement membrane mimic based on hydrophilic, natural polymers. 3D pore gradients are formed by synthetic polymers such as Poly-L-lactic acid (PLLA) by freeze-extraction method. 2D nanofibrillar surfaces are formed by using collagen/alginate followed by a crosslinking step with a natural crosslinker (genipin). This nanofibrillar film was built up by layer by layer (LbL) deposition method of the two oppositely charged molecules, collagen and alginate. Finally, an implant where different areas can accommodate different cell types, as this is necessary for many multicellular tissues, can be obtained. By, this way cellular movement in different directions by different cell types can be controlled. Such a system is described for the specific case of trachea regeneration, but it can be modified for other target organs. Analysis of cell migration and the possible methods for creating different pore gradients are elaborated. The next step in the analysis of such implants is their characterization after implantation. However, histological analysis of metallic implants is a long and cumbersome process, thus for monitoring host reaction to metallic implants in vivo an alternative method based on monitoring CGA and different blood proteins is also described. These methods can be used for developing in vitro custom-made migration and colonization tests and also be used for analysis of functionalized metallic implants in vivo without histology. PMID:23851618
Vrana, Nihal E; Dupret-Bories, Agnes; Chaubaroux, Christophe; Rieger, Elisabeth; Debry, Christian; Vautier, Dominique; Metz-Boutigue, Marie-Helene; Lavalle, Philippe
2013-07-01
Metallic implants, especially titanium implants, are widely used in clinical applications. Tissue in-growth and integration to these implants in the tissues are important parameters for successful clinical outcomes. In order to improve tissue integration, porous metallic implants have being developed. Open porosity of metallic foams is very advantageous, since the pore areas can be functionalized without compromising the mechanical properties of the whole structure. Here we describe such modifications using porous titanium implants based on titanium microbeads. By using inherent physical properties such as hydrophobicity of titanium, it is possible to obtain hydrophobic pore gradients within microbead based metallic implants and at the same time to have a basement membrane mimic based on hydrophilic, natural polymers. 3D pore gradients are formed by synthetic polymers such as Poly-L-lactic acid (PLLA) by freeze-extraction method. 2D nanofibrillar surfaces are formed by using collagen/alginate followed by a crosslinking step with a natural crosslinker (genipin). This nanofibrillar film was built up by layer by layer (LbL) deposition method of the two oppositely charged molecules, collagen and alginate. Finally, an implant where different areas can accommodate different cell types, as this is necessary for many multicellular tissues, can be obtained. By, this way cellular movement in different directions by different cell types can be controlled. Such a system is described for the specific case of trachea regeneration, but it can be modified for other target organs. Analysis of cell migration and the possible methods for creating different pore gradients are elaborated. The next step in the analysis of such implants is their characterization after implantation. However, histological analysis of metallic implants is a long and cumbersome process, thus for monitoring host reaction to metallic implants in vivo an alternative method based on monitoring CGA and different blood proteins is also described. These methods can be used for developing in vitro custom-made migration and colonization tests and also be used for analysis of functionalized metallic implants in vivo without histology.
Esmaeili, N; Salimi, A; Zohuriaan-Mehr, M J; Vafayan, M; Meyer, W
2018-05-23
Bio-resourced thermosetting epoxy foam was synthesized from tannic acid toward two different applications e.g., dye-decontaminating and thermo-insulating. Epoxidized tannic acid (ETA) foam was produced without using of organic volatile compounds or flammable foaming gases. The foam density, thermal conductivity and closed-cell content were studied. Besides, TGA showed high char yield (49% in N 2 and 48.3% in air) at 600 °C accompanied by high LOI (37.1 in N 2 and 36.8 in air). The high thermo-stability and intumescent char yield along with low thermal conductivity recommends the foam suitability for being used as an insulating material. Additionally, sorption of methylene blue onto ETA foam was kinetically investigated. The study of contact time, ionic strength, solution pH, initial sorbate concentration and desorption revealed the dependency of the sorption process to pH and initial sorbate concentration. The experimental data fitted well with the Langmuir isotherm (R 2 = 0.997), yielding maximum sorption capacity of 36.25 mg/g (ETA foam = 0.05 g, pH = 7, MB concentration = 50 ppm, Volume = 25 mL). The kinetic data verified that MB sorption could be represented by the pseudo second-order model. Overall, the ETA foam can be introduced as a candidate for removing cationic pollutants, thermal insulator, and self-extinguishing/intumescent materials. Copyright © 2018 Elsevier B.V. All rights reserved.
Reticulated vitreous carbon: a useful material for cell adhesion and tissue invasion.
Pec, M K; Reyes, R; Sánchez, E; Carballar, D; Delgado, A; Santamaría, J; Arruebo, M; Evora, C
2010-10-06
Diverse carbon materials have been used for tissue engineering and clinical implant applications with varying success. In this study, commercially available reticulated vitreous carbon (RVC) foams were tested in vitro and in vivo for compatibility with primary cell adhesion and tissue repair. Pores sizes were determined as 279 ± 98 μm. No hydroxyapatite deposition was detected after immersion of the foams in simulated body fluid. Nonetheless, RVC provided an excellent support for adhesion of mesenchymal stem cells (MSCs) as well as primary chondrocytes without any surface pre-treatment. Live cell quantification revealed neutral behaviour of the material with plastic adhered chondrocytes but moderate cytotoxicity with MSCs. Yet, rabbit implanted foams exhibited good integration in subcutaneous pockets and most importantly, total defect repair in bone. Probably due to the stiffness of the material, incompatibility with cartilage regeneration was found. Interestingly and in contrast to several other carbon materials, we observed a total lack of foreign body reactions. Our results and its outstanding porous interconnectivity and availability within a wide range of pore sizes convert RVC into an attractive candidate for tissue engineering applications in a variety of bone models and for ex vivo cell expansion for regenerative medical applications.
Polyurethane foam-covered breast implants: a justified choice?
Scarpa, C; Borso, G F; Vindigni, V; Bassetto, F
2015-01-01
Even if the safety of the polyurethane prosthesis has been the subject of many studies and professional and public controversies. Nowadays, polyurethane covered implants are very popular in plastic surgery for the treatment of capsular contracture. We have identified 41 papers (1 is a communication of the FDA) by using search browsers such as Pubmed, Medline, and eMedicine. Eleven manuscripts have been used for an introduction, and the remaining thirty have been subdivided into three tables whose results have been summarized in three main chapters: (1) capsular formation and contracture, (2) complications, (3) biodegradation and cancer risk. (1) The polyurethanic capsule is a well defined foreign body reaction characterized by synovial metaplasia, a thin layer of disarranged collagen fibers and a high vascularization. These features make possible a "young" capsule and a low occurrence of capsular contracture even over a long period (10 years); (2) the polyurethane implants may be difficult to remove but there is no evidence that they cause an increase in the other complications; (3) there is no evidence of polyurethane related cancer in long-term studies (after 5 years). Polyurethane foam covered breast implants remain a valid choice for the treatment of capsular contracture even if it would be very useful to verify the ease of removal of the prosthesis and to continue investigations on biodegradation products.
NASA Astrophysics Data System (ADS)
Sasidharan Pillai, Prasanth Kumar
This thesis explores the use of 1-butene cross metathesized palm oil (PMTAG) as a feedstock for preparation of polyols which can be used to prepare rigid and flexible polyurethane foams. PMTAG is advantageous over its precursor feedstock, palm oil, for synthesizing polyols, especially for the preparation of rigid foams, because of the reduction of dangling chain effects associated with the omega unsaturated fatty acids. 1-butene cross metathesis results in shortening of the unsaturated fatty acid moieties, with approximately half of the unsaturated fatty acids assuming terminal double bonds. It was shown that the associated terminal OH groups introduced through epoxidation and hydroxylation result in rigid foams with a compressive strength approximately 2.5 times higher than that of rigid foams from palm and soybean oil polyols. Up to 1.5 times improvement in the compressive strength value of the rigid foams from the PMTAG polyol was further obtained following dry and/or solvent assisted fractionation of PMTAG in order to reduce the dangling chain effects associated with the saturated components of the PMTAG. Flexible foams with excellent recovery was achieved from the polyols of PMTAG and the high olein fraction of PMTAG indicating that these bio-derived polyurethane foams may be suitable for flexible foam applications. PMTAG polyols with controlled OH values prepared via an optimized green solvent free synthetic strategy provided flexible foams with lower compressive strength and higher recovery; i.e., better flexible foam potential compared to the PMTAG derived foams with non-controlled OH values. Overall, this study has revealed that the dangling chain issues of vegetable oils can be addressed in part using appropriate chemical and physical modification techniques such as cross metathesis and fractionation, respectively. In fact, the rigidity and the compressive strength of the polyurethane foams were in very close agreement with the percentage of terminal hydroxyl and OH value of the polyol. The results obtained from the study can be used to convert PMTAG like materials into industrially valuable materials.
Intumescent composition, foamed product prepared therewith, and process for making same
NASA Technical Reports Server (NTRS)
Riccitiello, S. R.; Parker, J. A. (Inventor)
1973-01-01
An intumescent composition and the foamed product prepared by heating are discussed wherein the composition comprises the reaction product of para-benzoquinone dioxime and a concentrated mineral acid such as sulfuric acid, phosphoric acid, and polyphosphoric acid. The composition is useful as an intumescent agent either by itself or when combined with other materials. A fire-resistant and heat-insulating composition is provided by heating the intumescent composition above its intumescent temperature.
De novo design and structure-activity relationships of peptide emulsifiers and foaming agents.
Enser, M; Bloomberg, G B; Brock, C; Clark, D C
1990-04-01
A series of eight amphipathic peptides (8, 11, 15, 2 x 18, 22, 26, 29 amino acids in length) were designed to investigate the effects of amino acid composition, peptide length and secondary structure on surface activity assessed as emulsification and foaming activity. The potential for alpha-helix formation at the hydrophobic/hydrophilic interface was maximized through the use of helix-forming amino acids, a relatively large hydrophobic surface of 200 degrees of arc and ion pairs between basic and acidic amino acids on the hydrophilic surface. Emulsification activity increased rapidly between 11 and 22 residues as alpha-helicity in aqueous solution increased. Despite their small size, the peptides produced exceptionally stable emulsions, compared with proteins. Foaming activity was enhanced by the presence of aromatic amino acids and the activity of the best peptide examined was superior to that of bovine serum albumin and beta-lactoglobulin.
Hsu, Jui-Ting; Fuh, Lih-Jyh; Tu, Ming-Gene; Li, Yu-Fen; Chen, Kuan-Ting; Huang, Heng-Li
2013-04-01
This study investigated how the primary stability of a dental implant as measured by the insertion torque value (ITV), Periotest value (PTV), and implant stability quotient (ISQ) is affected by varying thicknesses of cortical bone and strengths of trabecular bone using synthetic bone models. Four synthetic cortical shells (with thicknesses of 0, 1, 2, and 3 mm) were attached to four cellular rigid polyurethane foams (with elastic moduli of 137, 47.5, 23, and 12.4 MPa) and one open-cell rigid polyurethane foam which mimic the osteoporotic bone (with an elastic modulus 6.5 MPa), to represent the jawbones with various cortical bone thicknesses and strengths of trabecular bone. A total of 60 bone specimens accompanied with implants was examined by a torque meter, Osstell resonance frequency analyzer, and Periotest electronic device. All data were statistically analyzed by two-way analysis of variance. In addition, second-order nonlinear regression was utilized to assess the correlations of the primary implant stability with the four cortex thicknesses and five strengths of trabecular bone. ITV, ISQ, and PTV differed significantly (p < .05) and were strongly correlated with the thickness of cortical bone (R(2) > 0.9) and the elastic modulus of trabecular bone (R(2) = 0.74-0.99). The initial stability at the time of implant placement is influenced by both the cortical bone thickness and the strength of trabecular bone; however, these factors are mostly nonlinearly correlated with ITV, PTV, and ISQ. Using ITV and PTV seems more suitable for identifying the primary implant stability in osteoporotic bone with a thin cortex. © 2011 Wiley Periodicals, Inc.
An Investigation on the Influence of Hyaluronic Acid on Polidocanol Foam Stability.
Chen, An-Wei; Liu, Yi-Ran; Li, Kai; Liu, Shao-Hua
2016-01-01
Foam sclerotherapy is an effective treatment strategy for varicose veins and venous malformations. Foam stability varies according to foam composition, volume, and injection technique. To evaluate the stability of polidocanol (POL) foam with the addition of hyaluronic acid (HA). Group A: 2 mL of 1% POL + 0 mL of 1% HA + 8 mL of air; Group B: 2 mL of 1% POL + 0.05 mL of 1% HA + 8 mL of air; Group C: 2 mL of 1% POL + 0.1 mL of 1% HA + 8 mL of air. Tessari's method was used for foam generation. The half-life, or the time for a volume of foam to be reduced to half of its original volume, was used to evaluate foam stability. Five recordings were made for each group. The half-life was 142.8 (±4.32) seconds for 1% POL without the addition of HA, 310.6 (±7.53) seconds with the addition of 0.05 mL of 1% HA, and 390.4 (±13.06) seconds with the addition of 0.1 mL of 1% HA. The stability of POL foam was highly increased by the addition of small amounts of HA.
A study of the crystallization, melting, and foaming behaviors of polylactic acid in compressed CO₂.
Zhai, Wentao; Ko, Yoorim; Zhu, Wenli; Wong, Anson; Park, Chul B
2009-12-16
The crystallization and melting behaviors of linear polylactic acid (PLA) treated by compressed CO(2) was investigated. The isothermal crystallization test indicated that while PLA exhibited very low crystallization kinetics under atmospheric pressure, CO(2) exposure significantly increased PLA's crystallization rate; a high crystallinity of 16.5% was achieved after CO(2) treatment for only 1 min at 100 degrees C and 6.89 MPa. One melting peak could be found in the DSC curve, and this exhibited a slight dependency on treatment times, temperatures, and pressures. PLA samples tended to foam during the gas release process, and a foaming window as a function of time and temperature was established. Based on the foaming window, crystallinity, and cell morphology, it was found that foaming clearly reduced the needed time for PLA's crystallization equilibrium.
Low density biodegradable shape memory polyurethane foams for embolic biomedical applications
Singhal, Pooja; Small, Ward; Cosgriff-Hernandez, Elizabeth; Maitland, Duncan J; Wilson, Thomas S
2014-01-01
Low density shape memory polymer foams hold significant interest in the biomaterials community for their potential use in minimally invasive embolic biomedical applications. The unique shape memory behavior of these foams allows them to be compressed to a miniaturized form, which can be delivered to an anatomical site via a transcatheter process, and thereafter actuated to embolize the desired area. Previous work in this field has described the use of a highly covalently crosslinked polymer structure for maintaining excellent mechanical and shape memory properties at the application-specific ultra low densities. This work is aimed at further expanding the utility of these biomaterials, as implantable low density shape memory polymer foams, by introducing controlled biodegradability. A highly covalently crosslinked network structure was maintained by use of low molecular weight, symmetrical and polyfunctional hydroxyl monomers such as Polycaprolactone triol (PCL-t, Mn 900 g), N,N,N0,N0-Tetrakis (hydroxypropyl) ethylenediamine (HPED), and Tris (2-hydroxyethyl) amine (TEA). Control over the degradation rate of the materials was achieved by changing the concentration of the degradable PCL-t monomer, and by varying the material hydrophobicity. These porous SMP materials exhibit a uniform cell morphology and excellent shape recovery, along with controllable actuation temperature and degradation rate. We believe that they form a new class of low density biodegradable SMP scaffolds that can potentially be used as “smart” non-permanent implants in multiple minimally invasive biomedical applications. PMID:24090987
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
... Polyurethane Foam Production and Fabrication, Lead Acid Battery Manufacturing, and Wood Preserving (Renewal... Polyurethane Foam Production and Fabrication, Lead Acid Battery Manufacturing, and Wood Preserving (40 CFR Part... battery manufacturing facilities, and 393 existing wood preserving facilities. The total annual responses...
Staphylococcus epidermidis adhesion on surface-treated open-cell Ti6Al4V foams.
Türkan, Uğur; Güden, Mustafa; Sudağıdan, Mert
2016-06-01
The effect of alkali and nitric acid surface treatments on the adhesion of Staphylococcus epidermidis to the surface of 60% porous open-cell Ti6Al4V foam was investigated. The resultant surface roughness of foam particles was determined from the ground flat surfaces of thin foam specimens. Alkali treatment formed a porous, rough Na2Ti5O11 surface layer on Ti6Al4V particles, while nitric acid treatment increased the number of undulations on foam flat and particle surfaces, leading to the development of finer surface topographical features. Both surface treatments increased the nanometric-scale surface roughness of particles and the number of bacteria adhering to the surface, while the adhesion was found to be significantly higher in alkali-treated foam sample. The significant increase in the number of bacterial attachment on the alkali-treated sample was attributed to the formation of a highly porous and nanorough Na2Ti5O11 surface layer.
Intumescent composition, foamed product prepared therewith and process for making same
NASA Technical Reports Server (NTRS)
Riccitiello, S. R.; Parker, J. A. (Inventor)
1974-01-01
An intumescent composition and the foamed product prepared by heating the composition are provided. The composition comprises the reaction product of para-benzoquinone dioxime and a concentrated mineral acid such as sulfuric acid, phosphoric acid, and polyphosphoric acid. The composition is useful as an intumescent agent either by itself or when combined with other materials. A fire-resistant and heat-insulating composition is provided by heating the intumescent composition above its intumescent temperature.
Stabilized aqueous foam systems and concentrate and method for making them
Rand, Peter B.
1984-01-01
This invention comprises a combination of a water soluble polymer of the polyacrylic acid type, a foam stabilizer of dodecyl alcohol, a surfactant, a solvent and water as a concentrate for use in producing stabilized aqueous foams. In another aspect, the invention comprises a solution of the concentrate with water. In still another aspect the invention includes a method of generating stabilized aqueous foams.
Plasma-Spray Metal Coating On Foam
NASA Technical Reports Server (NTRS)
Cranston, J.
1994-01-01
Molds, forms, and other substrates made of foams coated with metals by plasma spraying. Foam might be ceramic, carbon, metallic, organic, or inorganic. After coat applied by plasma spraying, foam left intact or removed by acid leaching, conventional machining, water-jet cutting, or another suitable technique. Cores or vessels made of various foam materials plasma-coated with metals according to method useful as thermally insulating containers for foods, liquids, or gases, or as mandrels for making composite-material (matrix/fiber) parts, or making thermally insulating firewalls in automobiles.
NASA Technical Reports Server (NTRS)
Gagliani, John (Inventor); Lee, Raymond (Inventor); Sorathia, Usman A. K. (Inventor)
1983-01-01
Copolyimide foams derived from a diester of 3,3',4,4'-benzophenonetetracarboxylic acid, an aromatic diamine, and a heterocyclic diamine. A molar concentration of the heterocyclic diamine approaching but not exceeding 0.42 is employed. This results in a flexible foam with a homogeneous cellular structure and a reduced compression set loss.
Optimization of process parameters for foam-mat drying of papaya pulp.
Kandasamy, Palani; Varadharaju, N; Kalemullah, S; Maladhi, D
2014-10-01
Experiments were carried out to optimize the process parameters for production of papaya powder using foam-mat drying. Papaya pulp was foamed by incorporating methyl cellulose (0.25, 0.5, 0.75 and 1 %, w/w), glycerol-mono-stearate (1, 2, 3 and 4 %, w/w) and egg white (5, 10, 15 and 20 %, w/w) as foaming agents. The maximum stable foam formation was 72, 90 and 125% at 0.75 % methyl cellulose, 3 % glycerol-mono-stearate and 15 % egg white respectively with 9°Brix pulp and whipping time of 20 min. The foamed pulp was dried at air temperature of 60, 65 and 70 °C with foam thickness of 2, 4, 6, 8 and 10 mm in a batch type cabinet dryer. The drying time required for foamed papaya pulp was lower than non-foamed pulp at all selected temperatures. Biochemical analysis results showed a significant reduction in ascorbic acid, β-carotene and total sugars in the foamed papaya dried product at higher foam thickness (6, 8 and 10 mm) and temperature (65 and 70 °C due to destruction at higher drying temperature and increasing time. There was no significant change in other biochemical constituents such as pH and acidity. The organoleptic and sensory evaluation of the quality attributes of papaya powder obtained from the pulp of 9°Brix added with 3 % glycerol-mono-stearate, whipped for 20 min and dried with a foam thickness of 4 mm at a temperature of 60 °C was found to be optimum to produce the foam-mat dried papaya powder.
A Study of the Crystallization, Melting, and Foaming Behaviors of Polylactic Acid in Compressed CO2
Zhai, Wentao; Ko, Yoorim; Zhu, Wenli; Wong, Anson; Park, Chul B.
2009-01-01
The crystallization and melting behaviors of linear polylactic acid (PLA) treated by compressed CO2 was investigated. The isothermal crystallization test indicated that while PLA exhibited very low crystallization kinetics under atmospheric pressure, CO2 exposure significantly increased PLA’s crystallization rate; a high crystallinity of 16.5% was achieved after CO2 treatment for only 1 min at 100 °C and 6.89 MPa. One melting peak could be found in the DSC curve, and this exhibited a slight dependency on treatment times, temperatures, and pressures. PLA samples tended to foam during the gas release process, and a foaming window as a function of time and temperature was established. Based on the foaming window, crystallinity, and cell morphology, it was found that foaming clearly reduced the needed time for PLA’s crystallization equilibrium. PMID:20054476
Tyring, Stephen; Solomon, James A; Staedtler, Gerald; Lott, Jason P; Nkulikiyinka, Richard; Shakery, Kaweh
2016-10-01
Patient-reported treatment outcomes are important for evaluating the impact of drug therapies on patient experience. A randomized, double-blind, vehicle-controlled, parallel-group, multicenter, phase 3 study was conducted in 961 participants to assess patient perception of efficacy, utility, and effect on quality of life (QOL) of an azelaic acid (AzA) 15% foam formulation for the treatment of papulopustular rosacea (PPR). Secondary end points included patient-reported global assessment of treatment response, global assessment of tolerability, and opinion on cosmetic acceptability and practicability of product use. Quality of life assessments included the Dermatology Quality of Life Index (DLQI) and Rosacea Quality of Life Index (RosaQOL). Self-reported global assessment of treatment response favored AzA foam over vehicle foam (P<.001), with 57.2% of the AzA foam group reporting excellent or good improvement versus 44.7% in the vehicle foam group. Tolerability was rated excellent or good in 67.8% of the AzA foam group versus 78.2% of the vehicle foam group. Mean overall DLQI scores at end of treatment (EoT) were improved (P=.018) in favor of the AzA foam group compared with the vehicle foam group. Both treatment groups showed improvements in RosaQOL. Treatment with AzA foam was associated with improved QOL and meaningful reductions in the patient-perceived burden of PPR, which correlates with earlier reported primary end points of this study and supports the inclusion of patient perspectives in studies evaluating the effects of topical dermatologic treatments.
New Proximal Femoral Compaction Blade Provides Strong Antirotation Stability of the Femoral Head.
Hayashi, Shinya; Hirata, Yukiaki; Okamoto, Daiki; Kakunai, Satoshi; Hashimoto, Shingo; Takayama, Koji; Matsumoto, Tomoyuki; Niikura, Takahiro; Fujishiro, Takaaki; Hiranaka, Takafumi; Nishida, Kotaro; Kuroda, Ryosuke
2017-05-01
This study investigated the mechanical properties of a new rectangular compaction blade and compared this blade with other types of nail. Three types of nail were tested: the Magnum lag screw (Robert Reid Inc, Tokyo, Japan), proximal femoral nail, and Magnum Fid blade (Robert Reid Inc). The nails were inserted into solid rigid polyurethane foam, and the torsional moments were loaded with an Instron testing machine (Instron, Kanagawa, Japan). The force curve was recorded, and the average maximum torque was calculated from this curve. A simulation study was performed with finite element models to determine the mechanism underlying differences in rotational stability. Mechanical testing showed that the new compaction blade had stronger resistance against rotational force than the helical blade and lag screw implants. Finite element analysis also showed that the new compaction blade had stronger resistance to migration of the polyurethane foam cylinder than the other implant types. In addition, the new compaction blade had strong rotational stability. This implant should be useful for the treatment of unstable trochanteric fracture in patients with osteoporosis. [Orthopedics. 2017; 40(3):e491-e494.]. Copyright 2017, SLACK Incorporated.
Murr, L E; Gaytan, S M; Medina, F; Lopez, H; Martinez, E; Machado, B I; Hernandez, D H; Martinez, L; Lopez, M I; Wicker, R B; Bracke, J
2010-04-28
In this paper, we examine prospects for the manufacture of patient-specific biomedical implants replacing hard tissues (bone), particularly knee and hip stems and large bone (femoral) intramedullary rods, using additive manufacturing (AM) by electron beam melting (EBM). Of particular interest is the fabrication of complex functional (biocompatible) mesh arrays. Mesh elements or unit cells can be divided into different regions in order to use different cell designs in different areas of the component to produce various or continually varying (functionally graded) mesh densities. Numerous design elements have been used to fabricate prototypes by AM using EBM of Ti-6Al-4V powders, where the densities have been compared with the elastic (Young) moduli determined by resonant frequency and damping analysis. Density optimization at the bone-implant interface can allow for bone ingrowth and cementless implant components. Computerized tomography (CT) scans of metal (aluminium alloy) foam have also allowed for the building of Ti-6Al-4V foams by embedding the digital-layered scans in computer-aided design or software models for EBM. Variations in mesh complexity and especially strut (or truss) dimensions alter the cooling and solidification rate, which alters the alpha-phase (hexagonal close-packed) microstructure by creating mixtures of alpha/alpha' (martensite) observed by optical and electron metallography. Microindentation hardness measurements are characteristic of these microstructures and microstructure mixtures (alpha/alpha') and sizes.
Fixation strength of a polyetheretherketone femoral component in total knee arthroplasty.
de Ruiter, Lennert; Janssen, Dennis; Briscoe, Adam; Verdonschot, Nico
2017-11-01
Introducing polyetheretherketone (PEEK) polymer as a material for femoral components in total knee arthroplasty (TKA) could potentially lead to a reduction of the cemented fixation strength. A PEEK implant is more likely to deform under high loads, rendering geometrical locking features less effective. Fixation strength may be enhanced by adding more undercuts or specific surface treatments. The aim of this study is to measure the initial fixation strength and investigate the associated failure patterns of three different iterations of PEEK-OPTIMA ® implants compared with a Cobalt-Chromium (CoCr) component. Femoral components were cemented onto trabecular bone analogue foam blocks and preconditioned with 86,400 cycles of compressive loading (2600 N-260 N at 1 Hz). They were then extracted while the force was measured and the initial failure mechanism was recorded. Four groups were compared: CoCr, regular PEEK, PEEK with an enhanced cement-bonding surface and the latter with additional surface primer. The mean pull-off forces for the four groups were 3814 N, 688 N, 2525 N and 2552 N, respectively. The initial failure patterns for groups 1, 3 and 4 were the same; posterior condylar foam fracture and cement-bone debonding. Implants from group 2 failed at the cement-implant interface. This study has shown that a PEEK-OPTIMA ® femoral TKA component with enhanced macro- and microtexture is able to replicate the main failure mechanism of a conventional CoCr femoral implant. The fixation strength is lower than for a CoCr implant, but substantially higher than loads occurring under in-vivo conditions. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.
Short-term risk of falling after cochlear implantation.
Stevens, Madelyn N; Baudhuin, Jacqueline E; Hullar, Timothy E
2014-01-01
Cochlear implantation is a highly effective intervention for hearing loss, but insertion of an implant into the cochlea is often accompanied by loss of residual hearing function. Sometimes, postoperative testing also shows loss of function in the semicircular canals or otolith organs. The effect of this loss on equilibrium, particularly in the short term following surgery, and the risk of falling due to this loss is unknown. We prospectively measured balance in 16 consecutive adult cochlear implant patients before and 2 weeks after surgery. Subjects stood on a foam pad with eyes closed, feet together and arms at the side. The length of time over which this posture could be maintained was recorded up to a maximum value of 30 s indicating normal performance. Ten of 16 subjects reached a maximal time on preoperative testing. Nine of 16 subjects lost balance function after surgery. Four of the 10 subjects with normal preoperative balance function lost function. Subjects older than the age of 60 were more likely to lose balance function than younger subjects. We used previously published values relating balance performance on foam to risk of falling to calculate the fall risk among our subjects. The relative risk of falling increased after surgery by more than threefold in some patients. Imbalance after cochlear implantation may be much more common, particularly in the short term, than previously appreciated. This imbalance is accompanied by an increased risk of falling in many patients. Careful preoperative counseling before implantation and postoperative therapeutic intervention to improve comfort and reduce the chance of falling may be warranted, particularly in patients at a risk for injuries from falls (level of evidence: 2b). © 2014 S. Karger AG, Basel.
Polymeric foams from cross-linkable poly-N-ary lenebenzimidazoles
NASA Technical Reports Server (NTRS)
Harrison, E. S.; Delano, C. B.; Riccitello, S. R. (Inventor)
1978-01-01
Foamed cross-linked poly-N-arylenebinzimidazoles are prepared by mixing an organic tetraamine and an ortho substituted aromatic dicarboxylic acid anhydride in the presence of a blowing agent, and then heating the prepolymer to a temperature sufficient to complete polymerization and foaming of the reactants. In another embodiment of the process, the reactants are heated to form a prepolymer. The prepolymer is then cured at higher temperatures to complete foaming and polymerization.
Fürst, David; Senck, Sascha; Hollensteiner, Marianne; Esterer, Benjamin; Augat, Peter; Eckstein, Felix; Schrempf, Andreas
2017-07-01
Artificial materials reflecting the mechanical properties of human bone are essential for valid and reliable implant testing and design. They also are of great benefit for realistic simulation of surgical procedures. The objective of this study was therefore to characterize two groups of self-developed synthetic foam structures by static compressive testing and by microcomputed tomography. Two mineral fillers and varying amounts of a blowing agent were used to create different expansion behavior of the synthetic open-cell foams. The resulting compressive and morphometric properties thus differed within and also slightly between both groups. Apart from the structural anisotropy, the compressive and morphometric properties of the synthetic foam materials were shown to mirror the respective characteristics of human vertebral trabecular bone in good approximation. In conclusion, the artificial materials created can be used to manufacture valid synthetic bones for surgical training. Further, they provide novel possibilities for studying the relationship between trabecular bone microstructure and biomechanical properties. Copyright © 2017 Elsevier B.V. All rights reserved.
Corrosion Behavior of Magnesium Based Foam Structure in Hank’s Solution
NASA Astrophysics Data System (ADS)
Franciska, P. L.; Erryani, A.; Annur, D.; Kartika, I.
2017-05-01
Metal foam is a new class of materials with promising applications and a unique combination of physical, chemical, and mechanical properties. The purpose of biodegradable implants is to support tissue regeneration and healing in a particular application by material degradation and implant replacement through the surrounding tissue. Magnesium alloys are expected to be degraded in the body and its corrosion products not deleterious to the surrounding tissue. In the present study, the foam metal was manufactured via powder metallurgy with a different variation of sintering temperature and TiH2 used as a foaming agent which are added to Mg-1Ca-3Zn alloy as much 3% wt TiH2. The sintering temperatures were 500, 550 and 600 °C with a constant holding time of 5 hours. It’s critical that the sintering temperature is carefully selected in consideration of their corrosion behavior. This paper reports the study of the behavior of the Mg-Ca-Zn alloy metal foam which evaluated by SEM, EDX, and electrochemical corrosion test in Hank’s solutions. After exposure, the SEM result of Mg-Ca-Zn-3TiH2 to Hank’s solution, a volcano-like structure is formed. The streams of H2 bubbles form at local sites on the Mg alloy surface where electrochemical reactions are taking place, leading to the particular structure with around shape and often with a hole in the center. The corresponding EDS result maps reveal enrichment of O, Ca, P and Mg as corrosion product. Potentiodynamic polarization experiments conducted at 37 °C and pH 7.4 indicated the increased biodegradation rates resulted from porous structure of foam samples. Corrosion rate in 500oC sintering temperature were 1.99 millimiles per year (mmpy) with corrosion current density (I corr ) 87.3.10-6 A/cm2, corrosion rate in 550 °C sintering temperature were 2,16 mmpy with I corr 94.4.10-6 A/cm2 and rate in 600 °C sintering temperature were 2.41 mmpy with I corr 105.10-6 A/cm2. The results showed that the increasing of sintering temperature could influence the corrosion resistance of Mg alloy.
Borkotoky, Shasanka Sekhar; Dhar, Prodyut; Katiyar, Vimal
2018-01-01
This article addresses the elegant and green approach for fabrication of bio-based poly (lactic acid) (PLA)/cellulose nanocrystal (CNCs) bionanocomposite foam (PLA/CNC) with cellular morphology and hydrophobic surface behavior. Highly porous (porosity >80%) structure is obtained with interconnected pores and the effect of CNCs in the cell density (N f ) and cell size of foams are thoroughly investigated by morphological analysis. The thermo-mechanical investigations are performed for the foam samples and almost ∼1.7 and ∼2.2 fold increase in storage modulus is observed for the compressive and tensile mode respectively. PLA/CNC based bionanocomposite foams displayed similar thermal stability as base PLA foam. Detailed investigations of decomposition behavior are studied by using hyphenated thermogravimetric analysis-fourier transmission infrared spectroscopy (TGA-FTIR) system. Almost ∼13% increment is observed in crystallinity at highest loading of CNCs compared to neat counterpart. To investigate the splitting and spreading phenomenon of the wettability of the samples, linear model is used to find the Young's contact angle and contact angle hysteresis (CAH). Besides, ∼6.1 folds reduction in the density of PLA and the nanocomposite foams compared to PLA carries much significance in specialized application areas where weight is an important concern. Copyright © 2017 Elsevier B.V. All rights reserved.
CO2-Controllable Foaming and Emulsification Properties of the Stearic Acid Soap Systems.
Xu, Wenlong; Gu, Hongyao; Zhu, Xionglu; Zhong, Yingping; Jiang, Liwen; Xu, Mengxin; Song, Aixin; Hao, Jingcheng
2015-06-02
Fatty acids, as a typical example of stearic acid, are a kind of cheap surfactant and have important applications. The challenging problem of industrial applications is their solubility. Herein, three organic amines-ethanolamine (EA), diethanolamine (DEA), and triethanolamine (TEA)-were used as counterions to increase the solubility of stearic acid, and the phase behaviors were investigated systematically. The phase diagrams were delineated at 25 and 50 °C, respectively. The phase-transition temperature was measured by differential scanning calorimetry (DSC) measurements, and the microstructures were vesicles and planar sheets observed by cryogenic transmission electron microscopy (cryo-TEM) observations. The apparent viscosity of the samples was determined by rheological characterizations. The values, rcmc, for the three systems were less than 30 mN·m(-1). Typical samples of bilayers used as foaming agents and emulsifiers were investigated for the foaming and emulsification assays. CO2 was introduced to change the solubility of stearic acid, inducing the transition of their surface activity and further achieving the goal of defoaming and demulsification.
Preparation of lactic acid bacteria fermented wheat-yoghurt mixtures.
Magala, Michal; Kohajdová, Zlatica; Karovičová, Jolana
2013-01-01
Tarhana, a wheat-yoghurt fermented mixture, is considered as a good source of saccharides, proteins, some vitamins and minerals. Moreover, their preparation is inexpensive and lactic acid fermentation offers benefits like product preservation, enhancement of nutritive value and sensory properties improvement. The aim of this work was to evaluate changes of some chemical parameters during fermentation of tarhana, when the level of salt and amount of yoghurt used were varied. Some functional and sensory characteristics of the fi nal product were also determined. Chemical analysis included determination of pH, titrable acidity, content of reducing saccharides, lactic, acetic and citric acid. Measured functional properties of tarhana powder were foaming capacity, foam stability, water absorption capacity, oil absorption capacity and emulsifying activity. Tarhana soups samples were evaluated for their sensory characteristics (colour, odor, taste, consistency and overall acceptability). Fermentation of tarhana by lactic acid bacteria and yeasts led to decrease in pH, content of reducing saccharides and citric acid, while titrable acidity and concentration of lactic and acetic acid increased. Determination of functional properties of tarhana powder showed, that salt absence and increased amount of yoghurt in tarhana recipe reduced foaming capacity and oil absorption capacity, whereas foam stability and water absorption capacity were improved. Sensory evaluation of tarhana soups showed that variations in tarhana recipe adversly affected sensory parameters of fi nal products. Variations in tarhana recipe (salt absence, increased proportion of yoghurt) led to changes in some chemical parameters (pH, titrable acidity, reducing saccharides, content of lactic, acetic and citric acid). Functional properties were also affected with changed tarhana recipe. Sensory characteristics determination showed, that standard tarhana fermented for 144 h had the highest overall acceptability.
Huang, Haifu; Tang, Yanmei; Xu, Lianqiang; Tang, Shaolong; Du, Youwei
2014-07-09
Here, a novel graphene composite foam with 3D lightweight continuous and interconnected nickel network was successfully synthesized by hydroiodic (HI) acid using nickel foam as substrate template. The graphene had closely coated on the backbone of the 3D nickel conductive network to form nickel network supported composite foam without any polymeric binder during the HI reduction of GO process, and the nickel conductive network can be maintained even in only a small amount of nickel with 1.1 mg/cm(2) and had replaced the traditional current collector nickel foam (35 mg/cm(2)). In the electrochemical measurement, a supercapacitor device based on the 3D nickel network and graphene composite foam exhibited high rate capability of 100 F/g at 0.5 A/g and 86.7 F/g at 62.5 A/g, good cycle stability with capacitance retention of 95% after 2000 cycles, low internal resistance (1.68 Ω), and excellent flexible properties. Furthermore, the gravimetric capacitance (calculated using the total mass of the electrode) was high up to 40.9 F/g. Our work not only demonstrates high-quality graphene/nickel composite foam, but also provides a universal route for the rational design of high performance of supercapacitors.
Foaming and emulsifying properties of pectin isolated from different plant materials
NASA Astrophysics Data System (ADS)
Yancheva, Nikoleta; Markova, Daniela; Murdzheva, Dilyana; Vasileva, Ivelina; Slavov, Anton
2016-03-01
The foaming and emulsifying properties of pectins obtained from waste rose petals, citrus pressings, grapefruit peels and celery were studied. It was found that the highest foaming capacity showed pectin derived from celery. The effect of pectin concentration on the foaming capacity of pectin solutions was investigated. For all the investigated pectins increasing the concentration led to increase of the foaming capacity. Emulsifying activity and emulsion stability of model emulsion systems (50 % oil phase) with 0.6 % pectic solutions were determined. The highest emulsifying activity and stability showed pectin isolated by dilute acid extraction from waste rose petals.
Doping of carbon foams for use in energy storage devices
Mayer, Steven T.; Pekala, Richard W.; Morrison, Robert L.; Kaschmitter, James L.
1994-01-01
A polymeric foam precursor, wetted with phosphoric acid, is pyrolyzed in an inert atmosphere to produce an open-cell doped carbon foam, which is utilized as a lithium intercalation anode in a secondary, organic electrolyte battery. Tests were conducted in a cell containing an organic electrolyte and using lithium metal counter and reference electrodes, with the anode located therebetween. Results after charge and discharge cycling, for a total of 6 cycles, indicated a substantial increase in the energy storage capability of the phosphorus doped carbon foam relative to the undoped carbon foam, when used as a rechargeable lithium ion battery.
Family Planning: Bosnian, Russian, Spanish, Nuer.
ERIC Educational Resources Information Center
Anoka County Community Health and Environmental Services, Coon Rapids, MN.
This guide provides information in English, Bosnian, Russian, Spanish, and Nuer on family planning. Topics covered include a variety of birth control methods: abstinence, condoms, contraceptive foam, birth control pills, the Depo-Provera shot, the Norplant implant, diaphragms, intrauterine devices, natural family planning, sterilization, and the…
High temperature surface effects of He + implantation in ICF fusion first wall materials
NASA Astrophysics Data System (ADS)
Zenobia, Samuel J.; Radel, R. F.; Cipiti, B. B.; Kulcinski, Gerald L.
2009-06-01
The first wall armor of the inertial confinement fusion reactor chambers must withstand high temperatures and significant radiation damage from target debris and neutrons. The resilience of multiple materials to one component of the target debris has been investigated using energetic (20-40 keV) helium ions generated in the inertial electrostatic confinement device at the University of Wisconsin. The materials studied include: single-crystalline, and polycrystalline tungsten, tungsten-coated tantalum-carbide 'foams', tungsten-rhenium alloy, silicon carbide, carbon-carbon velvet, and tungsten-coated carbon-carbon velvet. Steady-state irradiation temperatures ranged from 750 to 1250 °C with helium fluences between 5 × 10 17 and 1 × 10 20 He +/cm 2. The crystalline, rhenium alloyed, carbide foam, and powder metallurgical tungsten specimens each experienced extensive pore formation after He + irradiation. Flaking and pore formation occurred on silicon carbide samples. Individual fibers of carbon-carbon velvet specimens sustained erosion and corrugation, in addition to the roughening and rupturing of tungsten coatings after helium ion implantation.
Development of polyimide foams with blowing agents
NASA Technical Reports Server (NTRS)
Gagliani, John (Inventor); Sorathia, Usman A. K. (Inventor); Lee, Raymond (Inventor)
1985-01-01
A method of preparing a polyimide foam which includes the steps of: preparing, foaming, and curing a precursor containing at least one alkyl ester of 3,3'4,4'-benzophenonetetracarboxylic acid; a meta- or para-substituted aromatic diamine; a heterocyclic diamine; an aliphatic diamine; and a solid blowing agent. The blowing agent is added to said precursor in a concentration which is sufficient to effect at least one of the following attributes of the foam: cell size, proportion of open cells, cell density, and indentation load deflection.
Polyimide foam for the thermal insulation and fire protection
NASA Technical Reports Server (NTRS)
Rosser, R. W. (Inventor)
1973-01-01
The preparation of chemically resistant and flame retardant foams from polyfunctional aromatic carboxylic acid derivatives and organic polyisocyanates is outlined. It was found that polyimide foams of reproducible density above 1 lb./ft. and below 6 lbs./cu ft. can be obtained by employing in the reaction of least 2% by weight of siloxane-glycol copolymer as a surfactant which acts as a specific density control agent. Polyimide foams into which reinforcing fibers such as silicon dioxide and carbon fibers may be incorporated were also produced.
Zhifeng Zheng; Hui Pan; Yuanbo Huang; Chung Y. Hse
2011-01-01
Rigid polyurethane foams were prepared from the liquefied wood polyols, which was obtained by the liquefaction of southern pine wood in the presence of polyhydric alcohols with sulfuric acid catalyst by using microwave-assistant as an energy source. The properties of liquefied biomass-based polyols and the rigid polyurethane foams were investigated. The results...
NASA Technical Reports Server (NTRS)
Riccitiello, S. R.; Sawko, P. M.; Estrella, C. A. (Inventor)
1979-01-01
Polyimide foam products having greatly improved burn-through and flame-spread resistance are prepared by the reaction of aromatic polyisocyanates with aromatic dianhydrides in the presence of metallic salts of octoic acid. The salts, for example stannous octoate, ferric octoate and aluminum octoate, favor the formation of imide linkages at the expense of other possible reactions.
Davenport, Russell J.; Curtis, Thomas P.; Goodfellow, Michael; Stainsby, Fiona M.; Bingley, Marc
2000-01-01
The formation of viscous foams on aeration basins and secondary clarifiers of activated sludge plants is a common and widespread problem. Foam formation is often attributed to the presence of mycolic acid-containing actinomycetes (mycolata). In order to examine the relationship between the number of mycolata and foam, we developed a group-specific probe targeting the 16S rRNA of the mycolata, a protocol to permeabilize mycolata, and a statistically robust quantification method. Statistical analyses showed that a lipase-based permeabilization method was quantitatively superior to previously described methods (P << 0.05). When mixed liquor and foam samples were examined, most of the mycolata present were rods or cocci, although filamentous mycolata were also observed. A nested analysis of variance showed that virtually all of the measured variance occurred between fields of view and not between samples. On this basis we determined that as few as five fields of view could be used to give a statistically meaningful sample. Quantitative fluorescent in situ hybridization (FISH) was used to examine the relationship between foaming and the concentration of mycolata in a 20-m3 completely mixed activated sludge plant. Foaming occurred when the number of mycolata exceeded a certain threshold value. Baffling of the plant affected foaming without affecting the number of mycolata. We tentatively estimated that the threshold foaming concentration of mycolata was about 2 × 106 cells ml−1 or 4 × 1012 cells m−2. We concluded that quantitative use of FISH is feasible and that quantification is a prerequisite for rational investigation of foaming in activated sludge. PMID:10698786
Chen, Linmu; Zhang, Jun; Deng, Xiao; Liu, Yan; Yang, Xi; Wu, Qiong; Yu, Chao
2017-09-23
The leading cause of morbidity and mortality is the result of cardiovascular disease, mainly atherosclerosis. The formation of macrophage foam cells by ingesting ox-LDL and focal retention in the subendothelial space are the hallmarks of the early atherosclerotic lesion. Lysophosphatidic acid (LPA), which is a low-molecular weight lysophospholipid enriched in oxidized LDL, exerts a range of effects on the cardiovascular system. Previous reports show that LPA increases the uptake of ox-LDL to promote the formation of foam cells. However, as the most active component of ox-LDL, there is no report showing whether LPA directly affects foam cell formation. The aim of this study was to investigate the effects of LPA on foam cell formation, as well as to elucidate the underlying mechanism. Oil red O staining and a Cholesterol/cholesteryl ester quantitation assay were used to evaluate foam cell formation in Raw264.7 macrophage cells. We utilized a Western blot and RT-PCR to investigate the relationship between LPA receptors and lipid transport related proteins. We found that LPA promoted foam cell formation, using 200 μM for 24 h. Meanwhile, the expression of the Scavenger receptor BI (SRBI), which promotes the efflux of free cholesterol, was decreased. Furthermore, the LPA 1/3 receptor antagonist Ki16425 significantly abolished the LPA effects, indicating that LPA 1/3 was involved in the foam cell formation and SRBI expression induced by LPA. Additionally, the LPA-induced foam cell formation was blocked with an AKT inhibitor. Our results suggest that LPA-enhanced foam cell formation is mediated by LPA 1/3 -AKT activation and subsequent SRBI expression. Copyright © 2017. Published by Elsevier Inc.
Coelho, Elisabete; Reis, Ana; Domingues, M Rosário M; Rocha, Sílvia M; Coimbra, Manuel A
2011-04-13
The foam of sparkling wines is a key parameter of their quality. However, the compounds that are directly involved in foam formation and stabilization are not yet completely established. In this work, seven sparkling wines were produced in Bairrada appellation (Portugal) under different conditions and their foaming properties evaluated using a Mosalux-based device. Fractionation of the sparkling wines into four independent fractions, (1) high molecular weight material, with molecular weight higher than 12 kDa (HMW), (2) hydrophilic material with molecular weigh between 1 and 12 kDa (AqIMW), (3) hydrophobic material with molecular weigh between 1 and 12 kDa (MeIMW), and (4) hydrophobic material with a molecular weight lower than 1 kDa (MeLMW), allowed the observation that the wines presenting the lower foam stability were those that presented lower amounts of the MeLMW fraction. The fraction that presented the best foam stability was HMW. When HMW is combined with MeLMW fraction, the foam stability largely increased. This increase was even larger, approaching the foam stability of the sparkling wine, when HMW was combined with the less hydrophobic subfraction of MeLMW (fraction 3). Electrospray tandem mass spectrometry (ESI-MS/MS) of fraction 3 allowed the assignment of polyethylene glycol oligomers (n = 5-11) and diethylene glycol 8-hydroxytridecanoate glyceryl acetate. To observe if these molecules occur in sparkling wine foam, the MeLMW was recovered directly from the sparkling wine foam and was also analyzed by ESI-MS/MS. The presence of monoacylglycerols of palmitic and stearic acids, as well as four glycerylethylene glycol fatty acid derivatives, was observed. These surface active compounds are preferentially partitioned by the sparkling wine foam rather than the liquid phase, allowing the inference of their role as key components in the promotion and stabilization of sparkling wine foam.
Fabrication and Properties of polyacrylic acid by ionic surfactant disturbance method
NASA Astrophysics Data System (ADS)
Lawan, S.; Osotchan, T.; Chuajiw, W.; Subannajui, K.
2017-09-01
The formation of polymeric materials can be achieved by several methods such as melting and casting, screw extrusion, cross-linking of resin or rubber in a mold, and so on. In this work, the polyacrylic acid is formed by using the emulsion disturbance method. Despite extensively used in the colour painting and coating industries, acrylic emulsion can be processed into a foam and powder configuration by a reaction between acrylic emulsion and salt. The solidification hardly changes the volume between liquid emulsion and solidified polymer which means the final structure of polyacrylic acid is filled with opened air cells. The opened air cell structure is confirmed by the result from scanning electron microscopy. The chemical analysis and crystallography of acrylic powder and foam are examined by Fourier-transform infrared spectroscopy and X-ray diffraction respectively. The phase transformation and Thermal stability are studied by differential scanning calorimetry and thermo gravimetric analysis. Moreover, the mechanical properties of acrylic foam were observed by tensile, compressive and hardness test. In addition to the basic property analysis, acrylic foam was also used in the particle filtration application.
Culbert, Julie A; McRae, Jacqui M; Condé, Bruna C; Schmidtke, Leigh M; Nicholson, Emily L; Smith, Paul A; Howell, Kate S; Boss, Paul K; Wilkinson, Kerry L
2017-02-22
The chemical composition (protein, polysaccharide, amino acid, and fatty acid/ethyl ester content), foaming properties, and quality of 50 Australian sparkling white wines, representing the four key production methods, that is, Méthode Traditionelle (n = 20), transfer (n = 10), Charmat (n = 10), and carbonation (n = 10), were studied. Méthode Traditionelle wines were typically rated highest in quality and were higher in alcohol and protein contents, but lower in residual sugar and total phenolics, than other sparkling wines. They also exhibited higher foam volume and stability, which might be attributable to higher protein concentrations. Bottle-fermented Méthode Traditionelle and transfer wines contained greater proportions of yeast-derived mannoproteins, whereas Charmat and carbonated wines were higher in grape-derived rhamnogalacturonans; however, total polysaccharide concentrations were not significantly different between sparkling wine styles. Free amino acids were most abundant in carbonated wines, which likely reflects production via primary fermentation only and/or the inclusion of nontraditional grape varieties. Fatty acids and their esters were not correlated with foaming properties, but octanoic and decanoic acids and their ethyl esters were present in Charmat and carbonated wines at significantly higher concentrations than in bottle-fermented wines and were negatively correlated with quality ratings. Research findings provide industry with a better understanding of the compositional factors driving the style and quality of sparkling white wine.
Enhanced Sintering of TiNi Shape Memory Foams under Mg Vapor Atmosphere
NASA Astrophysics Data System (ADS)
Aydoğmuş, Tarik; Bor, Şakir
2012-12-01
TiNi alloy foams are promising candidates for biomaterials to be used as artificial orthopedic implant materials for bone replacement applications in biomedical sector. However, certain problems exist in their processing routes, such as formation of unwanted secondary intermetallic phases leading to brittleness and deterioration of shape memory and superelasticity characteristics; and the contamination during processing resulting in oxides and carbonitrides which affect mechanical properties negatively. Moreover, the eutectic reaction present in Ti-Ni binary system at 1391 K (1118 °C) prevents employment of higher sintering temperatures (and higher mechanical properties) even when equiatomic prealloyed powders are used because of Ni enrichment of TiNi matrix as a result of oxidation. It is essential to prevent oxidation of TiNi powders during processing for high-temperature (>1391 K i.e., 1118 °C) sintering practices. In the current study, magnesium powders were used as space holder material to produce TiNi foams with the porosities in the range of 40 to 65 pct. It has been found that magnesium prevents secondary phase formation and contamination. It also prevents liquid phase formation while enabling employment of higher sintering temperatures by two-step sintering processing: holding the sample at 1373 K (1100 °C) for 30 minutes, and subsequently sintering at temperatures higher than the eutectic temperature, 1391 K (1118 °C). By this procedure, magnesium may allow sintering up to temperatures close to the melting point of TiNi. TiNi foams produced with porosities in the range of 40 to 55 pct were found to be acceptable as implant materials in the light of their favorable mechanical properties.
Doping of carbon foams for use in energy storage devices
Mayer, S.T.; Pekala, R.W.; Morrison, R.L.; Kaschmitter, J.L.
1994-10-25
A polymeric foam precursor, wetted with phosphoric acid, is pyrolyzed in an inert atmosphere to produce an open-cell doped carbon foam, which is utilized as a lithium intercalation anode in a secondary, organic electrolyte battery. Tests were conducted in a cell containing an organic electrolyte and using lithium metal counter and reference electrodes, with the anode located there between. Results after charge and discharge cycling, for a total of 6 cycles, indicated a substantial increase in the energy storage capability of the phosphorus doped carbon foam relative to the undoped carbon foam, when used as a rechargeable lithium ion battery. 3 figs.
Ardura, Juan A; Portal-Núñez, Sergio; Lozano, Daniel; Gutiérrez-Rojas, Irene; Sánchez-Salcedo, Sandra; López-Herradón, Ana; Mulero, Francisca; Villanueva-Peñacarrillo, María L; Vallet-Regí, María; Esbrit, Pedro
2016-08-01
Diabetes mellitus (DM) and aging are associated with bone fragility and increased fracture risk. Both (1-37) N- and (107-111) C-terminal parathyroid hormone-related protein (PTHrP) exhibit osteogenic properties. We here aimed to evaluate and compare the efficacy of either PTHrP (1-37) or PTHrP (107-111) loaded into gelatin-glutaraldehyde-coated hydroxyapatite (HA-Gel) foams to improve bone repair of a transcortical tibial defect in aging rats with or without DM, induced by streptozotocin injection at birth. Diabetic old rats showed bone structural deterioration compared to their age-matched controls. Histological and μ-computerized tomography studies showed incomplete bone repair at 4 weeks after implantation of unloaded Ha-Gel foams in the transcortical tibial defects, mainly in old rats with DM. However, enhanced defect healing, as shown by an increase of bone volume/tissue volume and trabecular and cortical thickness and decreased trabecular separation, occurred in the presence of either PTHrP peptide in the implants in old rats with or without DM. This was accompanied by newly formed bone tissue around the osteointegrated HA-Gel implant and increased gene expression of osteocalcin and vascular endothelial growth factor (bone formation and angiogenic markers, respectively), and decreased expression of Sost gene, a negative regulator of bone formation, in the healing bone area. Our findings suggest that local delivery of PTHrP (1-37) or PTHrP (107-111) from a degradable implant is an attractive strategy to improve bone regeneration in aged and diabetic subjects. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2060-2070, 2016. © 2016 Wiley Periodicals, Inc.
Characterization of commercial rigid polyurethane foams used as bone analogs for implant testing.
Calvert, Kayla L; Trumble, Kevin P; Webster, Thomas J; Kirkpatrick, Lynn A
2010-05-01
Mechanical properties and microstructure characterization of a series of graded commercial rigid polyurethane foams commonly used to mimic trabecular bone in testing orthopaedic devices is reported. Compressive testing conducted according to ASTM standard F1839-08, which requires large specimens (50.8 mm x 50.8 mm x 25.4 mm blocks) gave elastic modulus and compressive strength values ranging from 115 to 794 MPa and 4.7 to 24.7 MPa, respectively, for foams having densities of 0.240-0.641 g/cm(3). All these results were within the requirements of the specification for the corresponding grades. Compression testing using smaller specimens (7.5 mm diameter x 15 mm) typical of testing bone, gave results in good agreement with those obtained in the standard tests. Microstructural measurements showed the average pore size ranged from 125 to 234 microm for densities ranging from 0.641 to 0.159 g/cm(3), respectively. The relative modulus as a function of relative density of the foams fit well to the model of Gibson and Ashby. Cyclic testing revealed hysteresis in the lower density foams with a loading modulus statistically equivalent to that measured in monotonic testing. Shore DO durometry (hardness) measurements show good correlations to elastic modulus and compressive strength. The results suggest additional parameters to consider for the evaluation of polyurethane foams for bone analog applications.
NASA Astrophysics Data System (ADS)
Park, Hyeji; Um, Teakyung; Hong, Kicheol; Kang, Jin Soo; Nam, Ho-Seok; Kwon, Kyungjung; Sung, Yung-Eun; Choe, Heeman
2018-06-01
With its well-known popularity in structural applications, considerable attention has recently been paid to iron (Fe) and its oxides for its promising functional applications such as biodegradable implants, water-splitting electrodes, and the anode of lithium-ion batteries. For these applications, iron and its oxides can be even further utilized in the form of porous structures. In order to control the pore size, shape, and amount, we synthesized Fe foams using suspensions of micrometric Fe2O3 powder reduced to Fe via freeze casting in water or liquid camphene as a solvent through sublimation of either ice or camphene under 5 pct H2/Ar gas and sintering. We then compared them and found that the resulting Fe foam using water as a solvent (p = 71.7 pct) showed aligned lamellar macropores replicating ice dendrite colonies, while Fe foam using camphene as a solvent (p = 68.0 pct) exhibited interconnected equiaxed macropores replicating camphene dendrites. For all directions with respect to the loading axis, the compressive behavior of the water-based Fe foam with a directional elongated wall pore structure was anisotropic (11.6 ± 0.9 MPa vs 7.8 ± 0.8 MPa), whereas that of the camphene-based Fe foam with a random round pore structure was nearly isotropic (12.0 ± 1.1 MPa vs 11.6 ± 0.4 MPa).
Bio-based Polymer Foam from Soyoil
NASA Astrophysics Data System (ADS)
Bonnaillie, Laetitia M.; Wool, Richard P.
2006-03-01
The growing bio-based polymeric foam industry is presently lead by plant oil-based polyols for polyurethanes and starch foams. We developed a new resilient, thermosetting foam system with a bio-based content higher than 80%. The acrylated epoxidized soybean oil and its fatty acid monomers is foamed with pressurized carbon dioxide and cured with free-radical initiators. The foam structure and pore dynamics are highly dependent on the temperature, viscosity and extent of reaction. Low-temperature cure hinds the destructive pore coalescence and the application of a controlled vacuum results in foams with lower densities ˜ 0.1 g/cc, but larger cells. We analyze the physics of foam formation and stability, as well as the structure and mechanical properties of the cured foam using rigidity percolation theory. The parameters studied include temperature, vacuum applied, and cross-link density. Additives bring additional improvements: nucleating agents and surfactants help produce foams with a high concentration of small cells and low bulk density. Hard and soft thermosetting foams with a bio content superior to 80% are successfully produced and tested. Potential applications include foam-core composites for hurricane-resistant housing, structural reinforcement for windmill blades, and tissue scaffolds.
Foam composition for treating asbestos-containing materials and method of using same
DOE Office of Scientific and Technical Information (OSTI.GOV)
Block, J.; Krupkin, N.V.; Kuespert, D.R.
A composition for transforming a chrysotile asbestos-containing material into a non-asbestos material is disclosed. The composition comprises water, at least about 30% by weight of an acid component, at least about 0.1% by weight of a source of fluoride ions, and a stable foam forming amount of a foaming agent system having both cationic and non-ionic functionality. A method of transforming the asbestos-containing material into a non-asbestos material using the present composition in the form of a foam also disclosed.
Foam composition for treating asbestos-containing materials and method of using same
Block, Jacob; Krupkin, Natalia Vera; Kuespert, Daniel Reid; Nishioka, Gary Masaru; Lau, John Wing-Keung; Palmer, Nigel Innes
1998-04-28
A composition for transforming a chrysotile asbestos-containing material into a non-asbestos material is disclosed, wherein the composition comprises water, at least about 30% by weight of an acid component, at least about 0.1% by weight of a source of fluoride ions, and a stable foam forming amount of a foaming agent system having both cationic and non-ionic functionality. A method of transforming the asbestos-containing material into a non-asbestos material using the present composition in the form of a foam also disclosed.
Foam composition for treating asbestos-containing materials and method of using same
Block, J.; Krupkin, N.V.; Kuespert, D.R.; Nishioka, G.M.; Lau, J.W.K.; Palmer, N.I.
1998-04-28
A composition for transforming a chrysotile asbestos-containing material into a non-asbestos material is disclosed. The composition comprises water, at least about 30% by weight of an acid component, at least about 0.1% by weight of a source of fluoride ions, and a stable foam forming amount of a foaming agent system having both cationic and non-ionic functionality. A method of transforming the asbestos-containing material into a non-asbestos material using the present composition in the form of a foam also disclosed.
Shape-memory NiTi foams produced by replication of NaCl space-holders.
Bansiddhi, A; Dunand, D C
2008-11-01
NiTi foams were created with a structure (32-36% open pores 70-400 microm in size) and mechanical properties (4-25 GPa stiffness, >1000 MPa compressive strength, >42% compressive ductility, and shape-memory strains up to 4%) useful for bone implant applications. A mixture of NiTi and NaCl powders was hot-isostatically pressed at 950 and 1065 degrees C and the NaCl phase was then dissolved in water. The resulting NiTi foams show interconnected pores that replicate the shape and size of the NaCl powders, indicating that NiTi powders densified significantly before NaCl melted at 801 degrees C. Densifying NiTi or other metal powders above the melting point of the space-holder permits the use of NaCl, with the following advantages compared with higher-melting, solid space-holders such as oxides and fluorides used to date: (i) no temperature limit for densification; (ii) lower cost; (iii) greater flexibility in powder (and thus pore) shape; (iv) faster dissolution; (v) reduced metal corrosion during dissolution; (vi) lower toxicity if space-holder residues remain in the foam.
Kim, Duck-Rae; Lim, Young-Jun; Kim, Myung-Joo; Kwon, Ho-Beom; Kim, Sung-Hun
2011-11-01
This study tested the hypothesis that there would be differences in primary stability due to the presence of self cutting blades. We investigated the effect of a self-cutting blade implant design on the primary stability of tapered dental implants in a simulated low-density bone model. Implant fixtures with 2 different designs, one with self-cutting blades and the other without self-cutting blades, were fabricated in the same implant system. Insertion torque, resonance frequency analysis, reverse torque, and pull-out and push-in tests were evaluated in grade no. 10 solid rigid polyurethane foam. All 5 assessments of the group without self-cutting blades were significantly higher than those of the self-cutting group (P < .001). The implants without self-cutting blades create a lateral compression with increased contact surface area and consequently improve the primary stability in a simulated low-density bone model. Copyright © 2011 Mosby, Inc. All rights reserved.
An examination of the mechanisms for stable foam formation in activated sludge systems.
Petrovski, Steve; Dyson, Zoe A; Quill, Eben S; McIlroy, Simon J; Tillett, Daniel; Seviour, Robert J
2011-02-01
Screening pure cultures of 65 mycolic acid producing bacteria (Mycolata) isolated mainly from activated sludge with a laboratory based foaming test revealed that not all foamed under the conditions used. However, for most, the data were generally consistent with the flotation theory as an explanation for foaming. Thus a stable foam required three components, air bubbles, surfactants and hydrophobic cells. With non-hydrophobic cells, an unstable foam was generated, and in the absence of surfactants, cells formed a greasy surface scum. Addition of surfactant converted a scumming population into one forming a stable foam. The ability to generate a foam depended on a threshold cell number, which varied between individual isolates and reduced markedly in the presence of surfactant. Consequently, the concept of a universal threshold applicable to all foaming Mycolata is not supported by these data. The role of surfactants in foaming is poorly understood, but evidence is presented for the first time that surfactin synthesised by Bacillus subtilis may be important. Copyright © 2010 Elsevier Ltd. All rights reserved.
2014-01-01
The work focuses on research related to determination of application possibility of new, ecofriendly boroorganic polyols in rigid polyurethane foams production. Polyols were obtained from hydroxypropyl urea derivatives esterified with boric acid and propylene carbonate. The influence of esterification type on properties of polyols and next on polyurethane foams properties was determined. Nitrogen and boron impacts on the foams' properties were discussed, for instance, on their physical, mechanical, and electric properties. Boron presence causes improvement of dimensional stability and thermal stability of polyurethane foams. They can be applied even at temperature 150°C. Unfortunately, introducing boron in polyurethanes foams affects deterioration of their water absorption, which increases as compared to the foams that do not contain boron. However, presence of both boron and nitrogen determines the decrease of the foams combustibility. Main impact on the decrease combustibility of the obtained foams has nitrogen presence, but in case of proper boron and nitrogen ratio their synergic activity on the combustibility decrease can be easily seen. PMID:24587721
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aghion, E., E-mail: egyon@bgu.ac.il; Perez, Y.
2014-10-15
Magnesium alloy foams have the potential to serve as structural material for regular light-weight applications as well as for biodegradable scaffold implants. However, their main disadvantage relates to the high reactivity of magnesium and consequently their natural tendency to corrode in regular service conditions and in physiological environments. The present study aims at evaluating the effect of porosity on the corrosion resistance of MRI 201S magnesium alloy foams in 0.9% NaCl solution and in phosphate buffer saline solution as a simulated physiological electrolyte. The magnesium foams were produced by powder metallurgy technology using space-holding particles to control the porosity content.more » Machined chips were used as raw material for the production of Mg alloy powder by milling process. The microstructure of the foams was examined using optical and scanning electron microscopy, X-ray diffraction, and X-ray photoelectron spectroscopy analysis. The corrosion behavior was evaluated by immersion test and potentiodynamic polarization analysis. The results obtained clearly demonstrate that the porosity has a significant effect on the corrosion resistance of the tested foams. Foams with 14–19% porosity have a corrosion rate of 4–10 mcd and 7–15 mcd in NaCl and phosphate buffer saline solution, respectively, compared to only 0.10 mcd for the same alloy in as cast conditions. This increased corrosion degradation of the Mg foams by more than one order of magnitude compared to the cast alloy may limit their potential application in regular and physiological environments. - Highlights: • Porosity has a detrimental effect on corrosion resistance of MRI 201S Mg foams. • 14–19% porosity increases the corrosion rate by more than one order of magnitude. • Accelerated corrosion limits the use of foams in regular/physiological environments.« less
Saksø, Mikkel; Jakobsen, Stig S; Saksø, Henrik; Baas, Jørgen; Jakobsen, Thomas; Søballe, Kjeld
2012-01-01
Interaction between implant surface and surrounding bone influences implant fixation. We attempted to improve the bone-implant interaction by 1) adding surface micro scale topography by acid etching, and 2) removing surface-adherent pro-inflammatory agents by plasma cleaning. Implant fixation was evaluated by implant osseointegration and biomechanical fixation. The study consisted of two paired animal sub-studies where 10 skeletally mature Labrador dogs were used. Grit blasted titanium alloy implants were inserted press fit in each proximal tibia. In the first study grit blasted implants were compared with acid etched grit blasted implants. In the second study grit blasted implants were compared with acid etched grit blasted implants that were further treated with plasma sterilization. Implant performance was evaluated by histomorphometrical investigation (tissue-to-implant contact, peri-implant tissue density) and mechanical push-out testing after four weeks observation time. Neither acid etching nor plasma sterilization of the grit blasted implants enhanced osseointegration or mechanical fixation in this press-fit canine implant model in a statistically significant manner. PMID:22962567
NASA Astrophysics Data System (ADS)
Nguyen, B. V.; Challagulla, K. S.; Venkatesh, T. A.; Hadjiloizi, D. A.; Georgiades, A. V.
2016-12-01
Unit-cell based finite element models are developed to completely characterize the role of porosity distribution and porosity volume fraction in determining the elastic, dielectric and piezoelectric properties as well as relevant figures of merit of 3-3 type piezoelectric foam structures. Eight classes of foam structures which represent structures with different types and degrees of uniformity of porosity distribution are identified; a Base structure (Class I), two H-type foam structures (Classes II, and III), a Cross-type foam structure (Class IV) and four Line-type foam structures (Classes V, VI, VII, and VIII). Three geometric factors that influence the electromechanical properties are identified: (i) the number of pores per face, pore size and the distance between the pores; (ii) pore orientation with respect to poling direction; (iii) the overall symmetry of the pore distribution with respect to the center of the face of the unit cell. To assess the suitability of these structures for such applications as hydrophones, bone implants, medical imaging and diagnostic devices, five figures of merit are determined via the developed finite element model; the piezoelectric coupling constant (K t ), the acoustic impedance (Z), the piezoelectric charge coefficient (d h ), the hydrostatic voltage coefficient (g h ), and the hydrostatic figure of merit (d h g h ). At high material volume fractions, foams with non-uniform Line-type porosity (Classes V and VII) where the pores are preferentially distributed perpendicular to poling direction, are found to exhibit the best combination of desirable piezoelectric figures of merit. For example, at about 50% volume fraction, the d h , g h , and d h g h figures of merit are 55%, 1600% and 2500% higher, respectively, for Classes V and VII of Line-like foam structures compared with the Base structure.
Synthesis and development of low cost, high temperature N-arylene polybenzimidazole foam material
NASA Technical Reports Server (NTRS)
Harrison, E. S.
1975-01-01
Polymer (and foam) studies followed two basic routes: (1) formation of high molecular weight uncyclized polyamide followed by subsequent fusion and cyclodehydration to yield NABI (foam) and (2) polymer and foam formation by reaction of diphenyl esters (or anhydrides) with the tetramine. The latter route was found much more attractive since considerable versatility in both basic polymer structure and crosslinkability is achievable. Preliminary studies on BAB, phthalic anhydride (PA), and 3, 3 (prime), 4, 4(prime) benzo pheno netetracarboxylic acid dianhydride (BTDA) as crosslinked polymer precursors were conducted. Nonmelting rigid char forming foams with densities as low as 2.7 lb/cubic ft. were achieved. The program was successful in the preparation of a potentially low cost, low density, high char yield, high temperature foam material.
Bioplastic composite foam prepared from poly(lactic acid) and natural wood flour
NASA Astrophysics Data System (ADS)
Suwannakas, Pokkes; Petrchwattana, Nawadon; Covavisaruch, Sirijutaratana
2016-03-01
The major drawbacks of Poly(lactic acid) (PLA) bioplastic are its cost and brittleness. This study aims to reduce the cost by foaming PLA reinforced with wood flour. A series of PLA/ natural fiber (WF) composite was prepared by using WF of selected conifers up to 5 wt%; each composite formulation was then foamed using 2 wt% of Azodicarbonamide (ADC) as chemical foaming agent. ADC effectively reduced the density of PLA and the PLA/WF composite foam by about 45% to 0.64 g/cm3 from 1.24 g/cm3 of neat PLA and 1.26 g/cm3 of PLA/WF composites when 2 wt% ADC was applied. Mechanical behaviors in terms of compressive and impact properties were investigated. With the presence of WF, the compressive stress increased with the WF content due to the good interfacial adhesion between the PLA matrix and the WF. This was verified by microscopic observation, leading to efficient stress transfer at the interface between PLA matrix and the WF. The presence of WF raised the specific compressive modulus and strength of PLA/WF composites to around 0.94 GPa.cm3/g and 2.65 MPa.cm3/g but foaming the PLA or the PLA/WF composites led to a dramatic reduction of the compressive modulus to 0.2-0.4 GPa.cm3/g, implying that the PLA and the PLA/WF foams had become softened. This was evidently observed in the significant reduction of hardness coupled with the vast drop of stress required to compressively deform the foams.
Van Nierop, Sandra N E; Evans, David E; Axcell, Barry C; Cantrell, Ian C; Rautenbach, Marina
2004-05-19
Beer consumers demand satisfactory and consistent foam stability; thus, it is a high priority for brewers. Beer foam is stabilized by the interaction between certain beer proteins, including lipid transfer protein 1 (LTP1), and isomerized hop alpha-acids, but destabilized by lipids. In this study it was shown that the wort boiling temperature during the brewing process was critical in determining the final beer LTP1 content and conformation. LTP1 levels during brewing were measured by an LTP1 ELISA, using antinative barley LTP1 polyclonal antibodies. It was observed that the higher wort boiling temperatures ( approximately 102 degrees C), resulting from low altitude at sea level, reduced the final beer LTP1 level to 2-3 microg/mL, whereas the lower wort boiling temperatures ( approximately 96 degrees C), resulting from higher altitudes (1800 m), produced LTP1 levels between 17 and 35 microg/mL. Low levels of LTP1 in combination with elevated levels of free fatty acids (FFA) resulted in poor foam stability, whereas beer produced with low levels of LTP1 and FFA had satisfactory foam stability. Previous studies indicated the need for LTP1 denaturing to improve its foam stabilizing properties. However, the results presented here show that LTP1 denaturation reduces its ability to act as a binding protein for foam-damaging FFA. These investigations suggest that wort boiling temperature is an important factor in determining the level and conformation of LTP1, thereby favoring satisfactory beer foam stability.
Next Generation Orthopaedic Implants by Additive Manufacturing Using Electron Beam Melting
Murr, Lawrence E.; Gaytan, Sara M.; Martinez, Edwin; Medina, Frank; Wicker, Ryan B.
2012-01-01
This paper presents some examples of knee and hip implant components containing porous structures and fabricated in monolithic forms utilizing electron beam melting (EBM). In addition, utilizing stiffness or relative stiffness versus relative density design plots for open-cellular structures (mesh and foam components) of Ti-6Al-4V and Co-29Cr-6Mo alloy fabricated by EBM, it is demonstrated that stiffness-compatible implants can be fabricated for optimal stress shielding for bone regimes as well as bone cell ingrowth. Implications for the fabrication of patient-specific, monolithic, multifunctional orthopaedic implants using EBM are described along with microstructures and mechanical properties characteristic of both Ti-6Al-4V and Co-29Cr-6Mo alloy prototypes, including both solid and open-cellular prototypes manufactured by additive manufacturing (AM) using EBM. PMID:22956957
Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.
Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja
Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.
NASA Astrophysics Data System (ADS)
Rapp, F.; Schneider, A.; Elsner, P.
2014-05-01
Biopolymers are becoming increasingly important to both industry and consumers. With regard to waste management, CO2 balance and the conservation of petrochemical resources, increasing efforts are being made to replace standard plastics with bio-based polymers. Nowadays biopolymers can be built for example of cellulose, lactic acid, starch, lignin or bio mass. The paper will present material properties of selected cellulose based polymers (cellulose propionate [CP], cellulose acetate butyrate [CAB]) and corresponding processing conditions for particle foams as well as characterization of produced parts. Special focus is given to the raw material properties by analyzing thermal behavior (differential scanning calorimetry), melt strength (Rheotens test) and molecular weight distribution (gel-permeation chromatography). These results will be correlated with the foaming behavior in a continuous extrusion process with physical blowing agents and underwater pelletizer. Process set-up regarding particle foam technology, including extrusion foaming and pre-foaming, will be shown. The characteristics of the resulting foam beads will be analyzed regarding part density, cell morphology and geometry. The molded parts will be tested on thermal conductivity as well as compression behavior (E-modulus, compression strength).
Foley, Christine Hyon; Kerns, David G; Hallmon, William W; Rivera-Hidalgo, Francisco; Nelson, Carl J; Spears, Robert; Dechow, Paul C; Opperman, Lynne A
2010-01-01
This study evaluated the effects of phosphate coating of acid-etched titanium on the mineral apposition rate (MAR) and new bone-to-implant contact (BIC) in a canine model. Titanium implants (2.2 3 4 mm) with acid-etched surfaces that were electrolytically phosphated or not were placed in 48 mandibular sites in six foxhounds. Tetracycline and calcein dyes were administered 1 week after implant placement and 1 week before sacrifice. At 12 weeks after implant placement, the animals were sacrificed. MAR and BIC were evaluated using fluorescence microscopy. Light microscopic and histologic evaluations were performed on undecalcified sections. Microscopic evaluation showed the presence of healthy osteoblasts lining bone surfaces near implants. Similar BIC was observed in phosphated and nonphosphated titanium implant sites. MAR was significantly higher around the nonphosphated titanium implant surfaces than around the phosphated titanium samples. No significant differences were found between dogs or implant sites. Acid-etched implants showed significantly higher MARs compared to acid-etched, phosphate-coated implants. Int J Maxillofac Implants 2010;25:278-286.
Di Stefano, Danilo Alessio; Arosio, Paolo; Gastaldi, Giorgio; Gherlone, Enrico
2017-07-08
Recent research has shown that dynamic parameters correlate with insertion energy-that is, the total work needed to place an implant into its site-might convey more reliable information concerning immediate implant primary stability at insertion than the commonly used insertion torque (IT), the reverse torque (RT), or the implant stability quotient (ISQ). Yet knowledge on these dynamic parameters is still limited. The purpose of this in vitro study was to evaluate whether an energy-related parameter, the torque-depth curve integral (I), could be a reliable measure of primary stability. This was done by assessing if (I) measurement was operator-independent, by investigating its correlation with other known primary stability parameters (IT, RT, or ISQ) by quantifying the (I) average error and correlating (I), IT, RT, and ISQ variations with bone density. Five operators placed 200 implants in polyurethane foam blocks of different densities using a micromotor that calculated the (I) during implant placement. Primary implant stability was assessed by measuring the ISQ, IT, and RT. ANOVA tests were used to evaluate whether measurements were operator independent (P>.05 in all cases). A correlation analysis was performed between (I) and IT, ISQ, and RT. The (I) average error was calculated and compared with that of the other parameters by ANOVA. (I)-density, IT-density, ISQ-density, and RT-density plots were drawn, and their slopes were compared by ANCOVA. The (I) measurements were operator independent and correlated with IT, ISQ, and RT. The average error of these parameters was not significantly different (P>.05 in all cases). The (I)-density, IT-density, ISQ-density, and RT-density curves were linear in the 0.16 to 0.49 g/cm³ range, with the (I)-density curves having a significantly greater slope than those regarding the other parameters (P≤.001 in all cases). The torque-depth curve integral (I) provides a reliable assessment of primary stability and shows a greater sensitivity to density variations than other known primary stability parameters. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Lohmann, C H; Schwartz, Z; Niederauer, G G; Carnes, D L; Dean, D D; Boyan, B D
2000-01-01
Optimal repair of chondral defects is likely to require both a suitable population of chondrogenic cells and a biodegradable matrix to provide a space-filling structural support during the early stages of cartilage formation. This study examined the ability of chondrocytes to support cartilage formation when incorporated into biodegradable scaffolds constructed from copolymers (PLG) of polylactic acid (PLA) and polyglycolic acid (PGA) and implanted in the calf muscle of nude mice. Scaffolds were fabricated to be more hydrophilic (PLG-H) or were reinforced with 10% PGA fibers (PLG-FR), increasing the stiffness of the implant by 20-fold. Confluent primary cultures of rat costochondral resting zone chondrocytes (RC) were loaded into PLG-H foams and implanted intramuscularly. To determine if growth factor pretreatment could modulate the ability of the cells to form new cartilage, RC cells were pretreated with recombinant human platelet derived growth factor-BB IPDGF-BB) for 4 or 24 h prior to implantation. To assess whether scaffold material properties could affect the ability of chondrogenic cells to form cartilage, RC cells were also loaded into PLG-FR scaffolds. To determine if the scaffolds or treatment with PDGF-BB affected the rate of chondrogenesis, tissue at the implant site was harvested at four and eight weeks post-operatively, fixed, decalcified and embedded in paraffin. Sections were obtained along the transverse plane of the lower leg, stained with haematoxylin and eosin, and then assessed by morphometric analysis for area of cartilage, area of residual implant, and area of fibrous connective tissue formation (fibrosis). Whether or not the cartilage contained hypertrophic cells was also assessed. The amount of residual implant did not change with time in any of the implanted tissues. The area occupied by PLG-FR implants was greater than that occupied by PLG-H implants at both time points. All implants were surrounded by fibrous connective tissue, whether they were seeded with RC cells or not. The amount of fibrosis was reduced at eight weeks for both implant types. When RC cells were present, the amount of fibrosis was less than seen in cell-free scaffolds. Pretreatment with PDGF-BB caused a slightly greater degree of fibrosis at four weeks than was seen if untreated cells were used in the implants. However, at eight weeks, if the cells had been exposed to PDGF-BB for 24 h, fibrosis was comparable to that seen associated with cell-free scaffolds. The cells supported an equivalent area of cartilage formation in both scaffolds. PDGF-BB caused a time-dependent decrease in cartilage formation at four weeks, but at eight weeks, there was a marked increase in cartilage formation in PDGF-BB-treated cells that was greatest in cells exposed for 4 h compared to those exposed for 24 h. Moreover, PDGF-BB decreased the formation of hypertrophic cells. The results indicate that in this model, RC cells produce cartilage; pretreatment of the RC cells with PDGF-BB promotes retention of a hyaline-like chondrogenic phenotype; and the material properties of the implant do not negatively impact on the ability of the cells to support chondrogenesis.
Euston, S R; Hughes, P; Naser, Md A; Westacott, R E
2008-11-01
Molecular dynamic simulations have been carried out on systems containing a mixture of barley lipid transfer protein (LTP) and cis-isocohumulone (a hop derived iso-alpha-acid) in one of its enol forms, in bulk water and at the vacuum-water interface. In solution, the cis-isocohumulone molecules bind to the surface of the LTP molecule. The mechanism of binding appears to be purely hydrophobic in nature via desolvation of the protein surface. Binding of hop acids to the LTP leads to a small change in the 3-D conformation of the protein, but no change in the proportion of secondary structure present in helices, even though there is a significant degree of hop acid binding to the helical regions. At the vacuum-water interface, cis-isocohumulone shows a high surface activity and adsorbs rapidly at the interface. LTP then shows a preference to bind to the preadsorbed hop acid layer at the interface rather than to the bare water-vacuum interface. The free energy of adsorption of LTP at the hop-vacuum-water interface is more favorable than for adsorption at the vacuum-water interface. Our results support the view that hop iso-alpha-acids promote beer foam stability by forming bridges between separate adsorbed protein molecules, thus strengthening the adsorbed protein layer and reducing foam breakdown by lamellar phase drainage. The results also suggest a second mechanism may also occur, whereby the concentration of protein at the interface is increased via enhanced protein adsorption to adsorbed hop acid layers. This too would increase foam stability through its effect on the stabilizing protein layer around the foam bubbles.
Development of a model for occipital fixation--validation of an analogue bone material.
Mullett, H; O'Donnell, T; Felle, P; O'Rourke, K; FitzPatrick, D
2002-01-01
Several implant systems may be used to fuse the skull to the upper cervical spine (occipitocervical fusion). Current biomechanical evaluation is restricted by the limitations of human cadaveric specimens. This paper describes the design and validation of a synthetic testing model of the occipital bone. Data from thickness measurement and pull-out strength testing of a series of human cadaveric skulls was used in the design of a high-density rigid polyurethane foam model. The synthetic occipital model demonstrated repeatable and consistent morphological and biomechanical properties. The model provides a standardized environment for evaluation of occipital implants.
Stabilizing nanocellulose-nonionic surfactant composite foams by delayed Ca-induced gelation.
Gordeyeva, Korneliya S; Fall, Andreas B; Hall, Stephen; Wicklein, Bernd; Bergström, Lennart
2016-06-15
Aggregation of dispersed rod-like particles like nanocellulose can improve the strength and rigidity of percolated networks but may also have a detrimental effect on the foamability. However, it should be possible to improve the strength of nanocellulose foams by multivalent ion-induced aggregation if the aggregation occurs after the foam has been formed. Lightweight and highly porous foams based on TEMPO-mediated oxidized cellulose nanofibrils (CNF) were formulated with the addition of a non-ionic surfactant, pluronic P123, and CaCO3 nanoparticles. Foam volume measurements show that addition of the non-ionic surfactant generates wet CNF/P123 foams with a high foamability. Foam bubble size studies show that delayed Ca-induced aggregation of CNF by gluconic acid-triggered dissolution of the CaCO3 nanoparticles significantly improves the long-term stability of the wet composite foams. Drying the Ca-reinforced foam at 60 °C results in a moderate shrinkage and electron microscopy and X-ray tomography studies show that the pores became slightly oblate after drying but the overall microstructure and pore/foam bubble size distribution is preserved after drying. The elastic modulus (0.9-1.4 MPa) of Ca-reinforced composite foams with a density of 9-15 kg/m(3) is significantly higher than commercially available polyurethane foams used for thermal insulation. Copyright © 2016 Elsevier Inc. All rights reserved.
Shimoyama, Ami; Kido, Shoko; Kinekawa, Yoh-ichi; Doi, Yukio
2008-10-08
The water extract of guar meal ( Cyamopsis tetragonolobus) was examined for its foamability. Compared with egg white, the extract showed an extraordinary foam stability: no drainage after 3 h of standing in contrast to 65% drainage for egg white at the same protein concentration. The acid-precipitated protein from the extract was responsible for the high foamability and designated guar foaming albumin (GFA). The foaming activity of GFA was 20 times higher than that of egg white. GFA consisted of two subunits with molecular masses of 6 and 11 kDa linked to each other through disulfide bonds. The cleavage of disulfide bonds in GFA affected the foamability only slightly. GFA remarkably decreased the surface tension of water at low protein concentrations. Immunoblotting analysis demonstrated that GFA did not react to the antisera from allergic patients against plant food. These results suggest that GFA serves as an effective food additive in developing protein-stabilized foam.
NASA Astrophysics Data System (ADS)
Horn, John; Ortega, Jason; Hartman, Jonathan; Maitland, Duncan
2015-11-01
To prevent their rupture, intracranial aneurysms are often treated with endovascular metal coils which fill the aneurysm sac and isolate it from the arterial flow. Despite its widespread use, this method can result in suboptimal outcomes leading to aneurysm recurrence. Recently, shape memory polymer foam has been proposed as an alternative aneurysm filler. In this work, a computational model has been developed to predict thrombus formation in blood in response to such cardiovascular implantable devices. The model couples biofluid and biochemical phenomena present as the blood interacts with a device and stimulates thrombus formation. This model is applied to simulations of both metal coil and shape memory polymer foam treatments within an idealized 2D aneurysm geometry. Using the predicted thrombus responses, the performance of these treatments is evaluated and compared. The results suggest that foam-treated aneurysms may fill more quickly and more completely with thrombus than coil-filled aneurysms, potentially leading to improved long-term aneurysm healing. This work was performed in part under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Seeber, G; Buchmeiser, M R; Bonn, G K; Bertsch, T
1998-06-05
A high-capacity carboxylic acid-functionalized resin prepared by ring-opening metathesis polymerization based on cross-linked endo,endo-poly(norborn-2-ene-5,6-dicarboxylic acid) was used for the sampling of volatile, airborne amines from polyurethane (PU) foams. Six tertiary amines which represent commonly used promotors for the formation of PUs from diisocyanates and polyols, namely pentamethyldiethylenetriamine, diazabicyclooctane, N-methylmorpholine, N-ethylmorphine, 1,4-dimethylpiperazine and N,N-dimethylethanolamine, were sorbed onto the new resin. The sorption behavior of the new material was investigated in terms of loading capacities, the influence of concentration, flow-rate as well as of the amount of resin. Breakthrough curves were recorded from each single component as well as of mixtures thereof. Finally, the resin was used for the sampling of amines evaporating from PU foams applied in buildings. Further information about time dependent concentration profiles were obtained using a combination of GC-MS and Fourier transform IR spectroscopy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rapp, F., E-mail: florian.rapp@ict.fraunhofer.de, E-mail: anja.schneider@ict.fraunhofer.de; Schneider, A., E-mail: florian.rapp@ict.fraunhofer.de, E-mail: anja.schneider@ict.fraunhofer.de; Elsner, P., E-mail: peter.elsner@ict.fraunhofer.de
2014-05-15
Biopolymers are becoming increasingly important to both industry and consumers. With regard to waste management, CO{sub 2} balance and the conservation of petrochemical resources, increasing efforts are being made to replace standard plastics with bio-based polymers. Nowadays biopolymers can be built for example of cellulose, lactic acid, starch, lignin or bio mass. The paper will present material properties of selected cellulose based polymers (cellulose propionate [CP], cellulose acetate butyrate [CAB]) and corresponding processing conditions for particle foams as well as characterization of produced parts. Special focus is given to the raw material properties by analyzing thermal behavior (differential scanning calorimetry),more » melt strength (Rheotens test) and molecular weight distribution (gel-permeation chromatography). These results will be correlated with the foaming behavior in a continuous extrusion process with physical blowing agents and underwater pelletizer. Process set-up regarding particle foam technology, including extrusion foaming and pre-foaming, will be shown. The characteristics of the resulting foam beads will be analyzed regarding part density, cell morphology and geometry. The molded parts will be tested on thermal conductivity as well as compression behavior (E-modulus, compression strength)« less
NASA Astrophysics Data System (ADS)
Xia, Yang; Zhu, Derong; Si, Shihui; Li, Degeng; Wu, Sen
2015-06-01
Porous nickel foam is used as a substrate for the development of rechargeable zinc//polyaniline battery, and the cathode electrophoresis of PANI microparticles in non-aqueous solution is applied to the fabrication of Ni foam supported PANI electrode, in which the corrosion of the nickel foam substrate is prohibited. The Ni foam supported PANI cathode with high loading is prepared by PANI electrophoretic deposition, and followed by PANI slurry casting under vacuum filtration. The electrochemical charge storage performance for PANI material is significantly improved by using nickel foam substrate via the electrophoretic interlayer. The specific capacity of the nickel foam-PANI electrode with the electrophoretic layer is higher than the composite electrode without the electrophoretic layer, and the specific capacity of PANI supported by Ni foam reaches up to 183.28 mAh g-1 at the working current of 2.5 mA cm-2. The present electrophoresis deposition method plays the facile procedure for the immobilization of PANI microparticles onto the surface of non-platinum metals, and it becomes feasible to the use of the Ni foam supported PANI composite cathode for the Zn/PANI battery in weak acidic electrolyte.
Molecular assembly, interfacial rheology and foaming properties of oligofructose fatty acid esters.
van Kempen, Silvia E H J; Schols, Henk A; van der Linden, Erik; Sagis, Leonard M C
2014-01-01
Two major types of food-grade surfactants used to stabilize foams are proteins and low molecular weight (LMW) surfactants. Proteins lower the surface tension of interfaces and tend to unfold and stabilize the interface by the formation of a visco-elastic network, which leads to high surface moduli. In contrast, LMW surfactants lower the surface tension more than proteins, but do not form interfaces with a high modulus. Instead, they stabilize the interface through the Gibbs-Marangoni mechanism that relies on rapid diffusion of surfactants, when surface tension gradients develop as a result of deformations of the interface. A molecule than can lower the surface tension considerably, like a LMW surfactant, but also provide the interface with a high modulus, like a protein, would be an excellent foam stabilizer. In this article we will discuss molecules with those properties: oligofructose fatty acid esters, both in pure and mixed systems. First, we will address the synthesis and structural characterization of the esters. Next, we will address self-assembly and rheological properties of air/water interfaces stabilized by the esters. Subsequently, this paper will deal with mixed systems of mono-esters with either di-esters and lauric acid, or proteins. Then, the foaming functionality of the esters is discussed.
Fattahi, Amir; Darabi, Masoud; Farzadi, Laya; Salmassi, Ali; Latifi, Zeinab; Mehdizadeh, Amir; Shaaker, Maghsood; Ghasemnejad, Tohid; Roshangar, Leila; Nouri, Mohammad
2018-03-01
Since fatty acid composition of uterus phospholipids is likely to influence embryo implantation, this study was conducted to investigate the effects of dietary omega-3 and -6 fatty acids on implantation rate as well as uterine phospholipid fatty acids composition during mice pre-implantation period. Sixty female mice were randomly distributed into:1) control (standard pellet), 2) omega-3 (standard pellet + 10% w/w of omega-3 fatty acids) and 3) omega-6 (standard pellet + 10% w/w of omega-6 fatty acids). Uterine phospholipid fatty acid composition during the pre-implantation window (days 1-5 of pregnancy) was analyzed using gas-chromatography. The implantation rate on the fifth day of pregnancy was also determined. Our results showed that on days 1, 2 and 3 of pregnancy, the levels of arachidonic acid (ARA) as well as total omega-6 fatty acids were significantly higher and the levels of linolenic acid and total omega-3 fatty acids were statistically lower in the omega-6 group compared to the omega-3 group (p < 0.05). On the fourth day of pregnancy, only the ARA, total omega-6 fatty acids, and poly-unsaturated fatty acids levels were significantly different between the two dietary supplemented groups (p < 0.05). There were positive correlations between the levels of omega-6 fatty acids, especially ARA, with the implantation rate. The present study showed that diets rich in omega-3 and -6 fatty acids could differently modify uterine phospholipid fatty acid composition and uterine levels of phospholipid ARA, and that the total omega-6 fatty acids had a positive association with the implantation rate. Copyright © 2017 Elsevier Inc. All rights reserved.
Draelos, Zoe Diana; Elewski, Boni E; Harper, Julie C; Sand, Meike; Staedtler, Gerald; Nkulikiyinka, Richard; Shakery, Kaweh
2015-07-01
Rosacea is a chronic relapsing skin disorder primarily affecting the face. Although its etiology is not well defined, rosacea is associated with immune dysregulation and inflammation potentiated by external factors. These manifestations lead to skin sensitivity and impaired quality of life. Azelaic acid (AzA) is approved for the treatment of rosacea in a 15% gel formulation. This phase 3 study evaluated the efficacy and safety of AzA in a 15% foam formulation for the treatment of papulopustular rosacea (PPR). Coprimary efficacy end points were treatment success according to investigator global assessment (IGA) and the nominal change in inflammatory lesion count (ILC) from baseline to the end of treatment (EoT). Adverse events (AEs) were evaluated as a measure of safety. The IGA success rate at EoT was significantly greater in the AzA foam group versus vehicle (P<.001; Cochran-Mantel-Haenszel test). Likewise, nominal ILC change at EoT in the AzA foam group showed a significantly greater decrease versus vehicle (P<.001; F test). Drug-related AEs were mainly mild to moderate, cutaneous, and local. Overall, the study results support the efficacy and safety of twice-daily AzA foam 15% in patients with PPR.
Polypyrrole electrodes doped with sulfanilic acid azochromotrop for electrochemical supercapacitors
NASA Astrophysics Data System (ADS)
Chen, S.; Zhitomirsky, I.
2013-12-01
In this work we demonstrate the feasibility of deposition of polypyrrole (PPy) films by electropolymerization on stainless steel substrates and fabrication of PPy powders by chemical polymerization using sulfanilic acid azochromotrop (SPADNS) as a new anionic dopant. The problem of low adhesion of PPy films to stainless steel substrates is addressed by the use of SPADNS, which exhibits chelating properties, promoting film formation. The use of fine particles, prepared by the chemical polymerization method, allows impregnation of Ni foams and fabrication of porous electrodes with high materials loading for electrochemical supercapacitors (ES). PPy films and Ni foam based PPy electrodes show capacitive behaviour in Na2SO4 electrolyte. The electron microscopy studies, impedance spectroscopy data and analysis of the SPADNS structure provide an insight into the factors, controlling capacitive behaviour. The Ni foam based electrodes offer advantages of improved capacitive behaviour at high materials loadings and good cycling stability. The area normalized and volume normalized specific capacitances are as high as 5.43 F cm-2 and 93.6 F cm-3, respectively, for materials loading of 35.4 mg cm-2. The capacitance retention of Ni foam based electrodes is 91.5% after 1000 cycles. The Ni foam based PPy electrodes are promising for application in ES.
Choi, Hae Won; Park, Young Seok; Chung, Shin Hye; Jung, Min Ho; Moon, Won; Rhee, Sang Hoon
2017-07-01
The aim of this study was to compare the initial stability as insertion and removal torque and the clinical applicability of novel orthodontic zirconia micro-implants made using a powder injection molding (PIM) technique with those parameters in conventional titanium micro-implants. Sixty zirconia and 60 titanium micro-implants of similar design (diameter, 1.6 mm; length, 8.0 mm) were inserted perpendicularly in solid polyurethane foam with varying densities of 20 pounds per cubic foot (pcf), 30 pcf, and 40 pcf. Primary stability was measured as maximum insertion torque (MIT) and maximum removal torque (MRT). To investigate clinical applicability, compressive and tensile forces were recorded at 0.01, 0.02, and 0.03 mm displacement of the implants at angles of 0°, 10°, 20°, 30°, and 40°. The biocompatibility of zirconia micro-implants was assessed via an experimental animal study. There were no statistically significant differences between zirconia micro-implants and titanium alloy implants with regard to MIT, MRT, or the amount of movement in the angulated lateral displacement test. As angulation increased, the mean compressive and tensile forces required to displace both types of micro-implants increased substantially at all distances. The average bone-to-implant contact ratio of prototype zirconia micro-implants was 56.88 ± 6.72%. Zirconia micro-implants showed initial stability and clinical applicability for diverse orthodontic treatments comparable to that of titanium micro-implants under compressive and tensile forces.
46 CFR 31.10-18 - Firefighting equipment: General-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... equipment shall be made: Table 31.10-18(b) Type unit Test Soda acid Discharge. Clean hose and inside of... made: Table 31.10-18(c) Type system Test Foam Systems utilizing a soda solution shall have such... for certification and the periodic inspection by discharging foam for approximately 15 seconds from...
46 CFR 31.10-18 - Firefighting equipment: General-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... equipment shall be made: Table 31.10-18(b) Type unit Test Soda acid Discharge. Clean hose and inside of... made: Table 31.10-18(c) Type system Test Foam Systems utilizing a soda solution shall have such... for certification and the periodic inspection by discharging foam for approximately 15 seconds from...
Foam injection molding of poly(lactic acid) with physical blowing agents
NASA Astrophysics Data System (ADS)
Pantani, R.; Sorrentino, A.; Volpe, V.; Titomanlio, G.
2014-05-01
Foam injection molding uses environmental friendly blowing agents under high pressure and temperature to produce parts having a cellular core and a compact solid skin (the so-called "structural foam"). The addition of a supercritical gas reduces the part weight and at the same time improves some physical properties of the material through the promotion of a faster crystallization; it also leads to the reduction of both the viscosity and the glass transition temperature of the polymer melt, which therefore can be injection molded adopting lower temperatures and pressures. These aspects are of extreme interest for biodegradable polymers, which often present a very narrow processing window, with the suitable processing temperatures close to the degradation conditions. In this work, foam injection molding was carried out by an instrumented molding machine, able to measure the pressure evolution in different positions along the flow-path. The material adopted was a biodegradable polymer, namely the Poly(lactic acid), PLA. The effect of a physical blowing agent (PBA) on the viscosity was measured. The density reduction and the morphology of parts obtained by different molding conditions was assessed.
Lajnaf, Roua; Picart-Palmade, Laetitia; Attia, Hamadi; Marchesseau, Sylvie; Ayadi, M A
2017-08-01
The effect of pH (4.3 or 6.5) and heat treatment (70°C or 90°C for 30min) on the foaming and interfacial properties of α-lactalbumin extracted from camel milk were studied. The increased temperature treatment changed the foaming properties of camel α-lactalbumin solution and its ability to unfold at the air-water interface. At neutral pH, heat treatment was found to improve foamability, whereas at acid pH (4.3) this property decreased. Foams were more stable after a heat treatment at pH 4.3 than at 6.5, due to higher levels of protein aggregation at low pH. Heat treatment at 90°C for 30min affected the physicochemical properties of the camel α-lactalbumin by increasing free thiol group concentration at pH 6.5. Heat treatment also caused changes in α-lactalbumin's surface charge. These results also confirm the pronounced aggregation of heated camel α-lactalbumin solution at acid pH. Copyright © 2017. Published by Elsevier B.V.
Insertion torque in different bone models with different screw pitch: an in vitro study.
Orlando, Bruno; Barone, Antonio; Giorno, Thierry M; Giacomelli, Luca; Tonelli, Paolo; Covani, Ugo
2010-01-01
Orthopedic surgeons use different types of screws for bone fixation. Whereas hard cortical bone requires a screw with a fine pitch, in softer cancellous bone a wider pitch might help prevent micromotion and eventually lead to greater implant stability. The aim of this study was to validate the assumption that fine-pitch implants are appropriate for cortical bone and wide-pitch implants are appropriate for cancellous bone. Wide-pitch and fine-pitch implants were inserted in both hard (D1 and D2) bone and soft (D3 and D4) bone, which was simulated by separate experimental blocks of cellular rigid polyurethane foam. A series of insertion sites in D1-D2 and D3-D4 experimental blocks were prepared using 1.5-mm and 2.5-mm drills. The final torque required to insert each implant was recorded. Wide-pitch implants displayed greater insertion torque (20% more than the fine-pitch implants) in cancellous bone and were therefore more suitable than fine-pitch implants. It is more appropriate to use a fine pitch design for implants, in conjunction with a 2.5-mm osteotomy site, in dense cortical bone (D1 or D2), whereas it is recommended to choose a wide-pitch design for implants, in conjunction with a 1.5-mm osteotomy site, in softer bone (D3 or D4).
Blending Novatein¯ thermoplastic protein with PLA for carbon dioxide assisted batch foaming
NASA Astrophysics Data System (ADS)
Walallavita, Anuradha; Verbeek, Casparus J. R.; Lay, Mark
2016-03-01
The convenience of polymeric foams has led to their widespread utilisation in everyday life. However, disposal of synthetic petroleum-derived foams has had a detrimental effect on the environment which needs to be addressed. This study uses a clean and sustainable approach to investigate the foaming capability of a blend of two biodegradable polymers, polylactic acid (PLA) and Novatein® Thermoplastic Protein (NTP). PLA, derived from corn starch, can successfully be foamed using a batch technique developed by the Biopolymer Network Ltd. NTP is a patented formulation of bloodmeal and chemical additives which can be extruded and injection moulded similar to other thermoplastics. However, foaming NTP is a new area of study and its interaction with blowing agents in the batch process is entirely unknown. Subcritical and supercritical carbon dioxide have been examined individually in two uniquely designed pressure vessels to foam various compositions of NTP-PLA blends. Foamed material were characterised in terms of expansion ratio, cell size, and cellular morphology in order to study how the composition of NTP-PLA affects foaming with carbon dioxide. It was found that blends with 5 wt. % NTP foamed using subcritical CO2 expanded up to 11 times due to heterogeneous nucleation. Morphology analysis using scanning electron microscopy showed that foams blown with supercritical CO2 had a finer cell structure with consistent cell size, whereas, foams blown with subcritical CO2 ranged in cell size and showed cell wall rupture. Ultimately, this research would contribute to the production of a biodegradable foam material to be used in packaging applications, thereby adding to the application potential of NTP.
Phosphoric acid as an asphalt modifier guidelines for use : acid type.
DOT National Transportation Integrated Search
2008-01-01
Any grade of phosphoric acid can be used as an asphalt modifier. The stiffening effect is asphalt dependent. All grades of acid will yield similar results. However, the more diluted grades contain water, which may result in foaming problems as the wa...
Heydarifard, Solmaz; Taneja, Kapila; Bhanjana, Gaurav; Dilbaghi, Neeraj; Nazhad, Mousa M; Kim, Ki-Hyun; Kumar, Sandeep
2018-02-01
Development of a foam-formed cellulose filter paper with high wet strength was carried out for application as a drinking water filter. The wet strength and antimicrobial activity of cellulose foam paper against several bacteria species (Bacillus subtilis MTCC 441 (Gram +ve), B. cereus NCDC 240 (Gram +ve), Pseudomonas aeruginosa NCDC 105 (Gram -ve), Klebsiella pneumonia NCDC 138 (Gram -ve), and Escherichia coli MTCC 40 (Gram -ve)) were investigated. The morphology and structure of the cellulose foam paper were characterized using scanning electron microscopy (SEM). The results of our study confirmed that glutaraldehyde solution or 1,2,3,4-butanetetracarboxylic acid (BTCA) added to cellulose foam paper pretreated with cationic polyacrylamide (C-PAM) provided very high and stable wet strength performance together with excellent antimicrobial properties. Copyright © 2017 Elsevier Ltd. All rights reserved.
Amino Acids Aided Sintering for the Formation of Highly Porous FeAl Intermetallic Alloys
Karczewski, Krzysztof; Stepniowski, Wojciech J.
2017-01-01
Fabrication of metallic foams by sintering metal powders mixed with thermally degradable compounds is of interest for numerous applications. Compounds releasing gaseous nitrogen, minimizing interactions between the formed gases and metallic foam by diluting other combustion products, were applied. Cysteine and phenylalanine, were used as gas releasing agents during the sintering of elemental Fe and Al powders in order to obtain metallic foams. Characterization was carried out by optical microscopy with image analysis, scanning electron microscopy with energy dispersive spectroscopy, and gas permeability tests. Porosity of the foams was up to 42 ± 3% and 46 ± 2% for sintering conducted with 5 wt % cysteine and phenylalanine, respectively. Chemical analyses of the formed foams revealed that the oxygen content was below 0.14 wt % and the carbon content was below 0.3 wt %. Therefore, no brittle phases could be formed that would spoil the mechanical stability of the FeAl intermetallic foams. The gas permeability tests revealed that only the foams formed in the presence of cysteine have enough interconnections between the pores, thanks to the improved air flow through the porous materials. The foams formed with cysteine can be applied as filters and industrial catalysts. PMID:28773106
Wei, Niu; Bin, Shi; Jing, Zhou; Wei, Sun; Yingqiong, Zhao
2014-06-01
To evaluate the short- and mid-term effects of commercial pure (cp) titanium implant surface topography on osseointegration, bone-regenerative potential and mechanical retention in the human maxilla and mandible. 32 micro-implants with the same geometry but with four different surface treatments were implanted in the maxilla and mandible of eight patients. Each patient received four micro-implants, one of each type. Percentage of bone-to-implant contact analysis and histological evaluation was carried 3, 6 and 12 weeks after implantation. Furthermore, reverse removal torque tests were conducted 3 and 6 weeks after implantation to analyze functional bone attachment. Implant surfaces tested were: machined, grit-blasted, acid-etched, and grit-blasted with acid-etch. One-way ANOVA was performed using the multiple comparison Fisher's test to determine significance of observed differences among test groups. The level of significance was established at 5% (P < 0.05). Mean and standard deviations of the test groups were calculated. Surface roughness had a significant correlation with the evolution of bone regeneration. The surfaces with roughness Ra approximately 4 microim (grit-blasted and grit-blasted with acid-etch), showed rapid tissue colonization compared to machine and acid-etched surfaces. The results of reverse removal torque tests confirmed a significant correlation between surface roughness and functional bone attachment. Grit-blasted and grit-blasted with acid etched surfaces showed higher retention values compared to machine and acid-etched implants. This finding was supported by higher bone-to-implant contact observed for rougher surfaces (grit-blasted and grit-blasted with acid etching).
Implant decontamination with phosphoric acid during surgical peri-implantitis treatment: a RCT.
Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M
2017-12-01
Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial is to evaluate the microbiological and clinical effectiveness of phosphoric acid as a decontaminating agent of the implant surface during surgical peri-implantitis treatment. Peri-implantitis lesions were treated with resective surgical treatment aimed at peri-implant granulation tissue removal, bone recontouring, and pocket elimination. Fifty-three implant surfaces in 28 patients were mechanically cleaned and treated with either 35% phosphoric etching gel (test group) or sterile saline (control group). Microbiological samples were obtained during surgery; clinical parameters were recorded at baseline and at 3 months after treatment. Data were analyzed using multi-variable linear regression analysis and multilevel statistics. Significant immediate reductions in total anaerobic bacterial counts on the implant surface were found in both groups. Immediate reduction was greater when phosphoric acid was used. The difference in log-transformed mean anaerobic counts between both procedures was not statistical significant (p = 0.108), but there were significantly less culture-positive implants after the decontamination procedure in the phosphoric acid group (p = 0.042). At 3 months post-surgery, 75% of the implants in the control group and 63.3% of the implants in the test group showed disease resolution. However, no significant differences in clinical and microbiological outcomes between both groups were found. The application of 35% phosphoric acid after mechanical debridement is superior to mechanical debridement combined with sterile saline rinsing for decontamination of the implant surface during surgical peri-implantitis treatment. However, phosphoric acid as implant surface decontaminant does not seem to enhance clinical outcomes on a 3-month follow-up. Netherlands National Trial Register, NTR5185 (www.trialregister.nl).
Embaby, Hassan E; Rayan, Ahmed M
2016-06-01
Chemical composition and nutritional evaluation as well as physicochemical and functional properties of seed flour of Acacia tortilis (Forssk.) Hayne ssp. raddiana were studied. The results indicated that seeds contained 5.30% moisture, 3.99% ash, 9.19% fat, 14.31% fiber, 27.21% protein and 45.30% carbohydrates. Potassium was the predominant element followed by calcium and then phosphorous. Phytic acid, tannins and trypsin inhibitor as antinutrients were detected. The amino acid profile compared well with FAO/WHO recommended pattern except for cystine/methionine, isoleucine, tyrosine/phenylalanine, lysine and threonine. Also, the first limiting amino acid was lysine. Fatty acid composition showed that linoleic acid was the major fatty acid, followed by palmitic, stearic, oleic and arachidic acids. The seed oil showed absorbance in the ultraviolet ranges, thus it can be used as a broad spectrum UV protectant. For physicochemical and functional properties, acacia seeds flour had excellent water holding index, swelling index, foaming capacity and foam stability. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ferreira, Cristiano Dietrich; Ziegler, Valmor; Lindemann, Igor da Silva; Hoffmann, Jessica Fernanda; Vanier, Nathan Levien; Oliveira, Maurício de
2018-04-25
The aim of this study was to evaluate the effects of moisture content and storage temperature on the percentage of moldy and fermented beans, mycotoxins levels, phenolic acids content, pasting properties of whole flour, as well as functional and thermal properties of protein isolates from black beans stored for 12 months. Beans stored under 14%/32 °C exhibited 16% of fermented grains, while at 17%/25 °C (42.3%) and 17%/32 °C (93.5%) of moldy plus fermented grains, named drastic conditions (DC). Mycotoxins were not present in grains from all storage conditions. Reduction of gallic, caffeic, and p-hydroxybenzoic acid contents, and increase of sinapic acid were observed in DC. Reduction of peak, final, and setback viscosities of bean flours in DC indicate the application in refrigerated and frozen products. The increase in foaming and reduction in foam degradation of the proteins highlights their use in beverages where the foam is an important factor. Copyright © 2017 Elsevier Ltd. All rights reserved.
Treatment of diseases due to infections and old age using anti-foaming agents.
Reinemann, Peter Joachim
2003-06-01
The biochemical changes taking place in the organism in the course of ageing and infectious processes result in substantial catabolic processes during which a variety of gases are created (in addition to carbon dioxide and nitrogen, depending on the conditions, methane, ammonia, hydrogen sulphide, mercaptan, etc. are also created) in addition to peptides and low molecular organic compounds. These gases are dispersed in the extra-cellular space and in the capillary system of blood and lymph in the form of micro-foam. The accompanied disturbance in the ability to flow considerably impairs the immune defence system which is inseparably connected to the transport of catabolic products. Any resulting diseases can be alleviated or even removed by the application of a simple physical-chemical principle. Anti-foaming agents (solutions, all types of dispersions, micro-emulsions) based on polydimethylsiloxane but also based on fatty acid esters (preferably unsaturated fatty acids) are proposed for treatment purposes.
Wilson, Glenn R.; Salyer, Ival O.; Ball, III, George L.
1976-07-13
By mixing one part of a prepolymer containing a polyamine partially polymerized with an organic epoxide and subsequently reacted with a fatty acid containing from 8 to 32 carbon atoms, and then reacting this prepolymer mixture with 3 parts of an organic epoxide, a composition was obtained which made a gas frothable, shear-stable, room temperature curing, low density foam. A particularly advantageous prepolymer was prepared using a polyamine selected from the group consisting of diethylenetriamine, triethylenetetramine, and tetraethylenepentamine, partially polymerized with an organic epoxide having an average molecular weight of about 350 and having an epoxide equivalent of 185 to 192, and reacted with 2-10 weight percent linoleic acid. When one part of this prepolymer was reacted with about three parts of epoxy, and frothed by whipping in air or nitrogen an epoxy foam was produced which could be troweled onto surfaces and into corners or crevices, and subsequently cured, at near ambient temperature, to a strong dimensionally stable foam product.
Alkali-enhanced steam foam oil recovery process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lau, H.C.
1986-09-02
This patent describes a process in which steam and steam-foaming surfactant are injected into a subterranean reservoir for displacing a relatively acidic oil toward a production location. An improvement is described which consisits of: injecting into the reservoir, at least as soon as at least some portion of the steam is injected, (a) a kind and amount of water soluble, alkaline material effective for ion-exchanging multivalent ions from the reservoir rocks and precipitating compounds containing those ions and for causing the aqueous liquid phase of the injected fluid to form soaps of substantially all of the petroleum acids in themore » reservoir oil, and (b) at least one surfactant arranged for foaming the steam and providing a preformed cosurfactant material capable of increasing the salinity requirement of an aqueous surfactant system in which soaps derived from the reservoir oil comprise a primary surfactant.« less
Blending Novatein{sup ®} thermoplastic protein with PLA for carbon dioxide assisted batch foaming
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walallavita, Anuradha, E-mail: asw15@students.waikato.ac.nz; Verbeek, Casparus J. R., E-mail: jverbeek@waikato.ac.nz; Lay, Mark, E-mail: mclay@waikato.ac.nz
2016-03-09
The convenience of polymeric foams has led to their widespread utilisation in everyday life. However, disposal of synthetic petroleum-derived foams has had a detrimental effect on the environment which needs to be addressed. This study uses a clean and sustainable approach to investigate the foaming capability of a blend of two biodegradable polymers, polylactic acid (PLA) and Novatein® Thermoplastic Protein (NTP). PLA, derived from corn starch, can successfully be foamed using a batch technique developed by the Biopolymer Network Ltd. NTP is a patented formulation of bloodmeal and chemical additives which can be extruded and injection moulded similar to othermore » thermoplastics. However, foaming NTP is a new area of study and its interaction with blowing agents in the batch process is entirely unknown. Subcritical and supercritical carbon dioxide have been examined individually in two uniquely designed pressure vessels to foam various compositions of NTP-PLA blends. Foamed material were characterised in terms of expansion ratio, cell size, and cellular morphology in order to study how the composition of NTP-PLA affects foaming with carbon dioxide. It was found that blends with 5 wt. % NTP foamed using subcritical CO{sub 2} expanded up to 11 times due to heterogeneous nucleation. Morphology analysis using scanning electron microscopy showed that foams blown with supercritical CO{sub 2} had a finer cell structure with consistent cell size, whereas, foams blown with subcritical CO{sub 2} ranged in cell size and showed cell wall rupture. Ultimately, this research would contribute to the production of a biodegradable foam material to be used in packaging applications, thereby adding to the application potential of NTP.« less
Polyols from Microwave Liquefied Bagasse and Its Application to Rigid Polyurethane Foam.
Xie, Jiulong; Zhai, Xianglin; Hse, Chung Yun; Shupe, Todd F; Pan, Hui
2015-12-08
Bagasse flour (BF) was liquefied using bi-component polyhydric alcohol (PA) as a solvent and phosphoric acid as a catalyst in a microwave reactor. The effect of BF to solvent ratio and reaction temperatures on the liquefaction extent and characteristics of liquefied products were evaluated. The results revealed that almost 75% of the raw bagasse was converted into liquid products within 9 min at 150 °C with a BF to solvent ratio of 1/4. The hydroxyl and acid values of the liquefied bagasse (LB) varied with the liquefied conditions. High reaction temperature combining with low BF to solvent ratio resulted in a low hydroxyl number for the LB. The molecular weight and polydispersity of the LB from reactions of 150 °C was lower compared to that from 125 °C. Rigid polyurethane (PU) foams were prepared from LB and methylene diphenyl diisocyanate (MDI), and the structural, mechanical and thermal properties of the PU foam were evaluated. The PU foams prepared using the LB from high reaction temperature showed better physical and mechanical performance in comparison to those from low reaction temperature. The amount of PA in the LB has the ability of increasing thermal stability of LB-PU foams. The results in this study may provide fundamental information on integrated utilizations of sugarcane bagasse via microwave liquefaction process.
Polyols from Microwave Liquefied Bagasse and Its Application to Rigid Polyurethane Foam
Xie, Jiulong; Zhai, Xianglin; Hse, Chung Yun; Shupe, Todd F.; Pan, Hui
2015-01-01
Bagasse flour (BF) was liquefied using bi-component polyhydric alcohol (PA) as a solvent and phosphoric acid as a catalyst in a microwave reactor. The effect of BF to solvent ratio and reaction temperatures on the liquefaction extent and characteristics of liquefied products were evaluated. The results revealed that almost 75% of the raw bagasse was converted into liquid products within 9 min at 150 °C with a BF to solvent ratio of 1/4. The hydroxyl and acid values of the liquefied bagasse (LB) varied with the liquefied conditions. High reaction temperature combining with low BF to solvent ratio resulted in a low hydroxyl number for the LB. The molecular weight and polydispersity of the LB from reactions of 150 °C was lower compared to that from 125 °C. Rigid polyurethane (PU) foams were prepared from LB and methylene diphenyl diisocyanate (MDI), and the structural, mechanical and thermal properties of the PU foam were evaluated. The PU foams prepared using the LB from high reaction temperature showed better physical and mechanical performance in comparison to those from low reaction temperature. The amount of PA in the LB has the ability of increasing thermal stability of LB-PU foams. The results in this study may provide fundamental information on integrated utilizations of sugarcane bagasse via microwave liquefaction process. PMID:28793725
Li, Huixiang; Wang, Yi; Ye, Daixin; Luo, Juan; Su, Biquan; Zhang, Song; Kong, Jilie
2014-09-01
A multi-walled carbon nanotubes (MWNTs) bridged mesocellular graphene foam (MGF) nanocomposite (MWNTs/MGF) modified glassy carbon electrode was fabricated and successfully used for simultaneous determination of ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (TRP). Comparing with pure MGF, MWNTs or MWNTs/GS (graphene sheets), MWNTs/MGF displayed higher catalytic activity and selectivity toward the oxidation of AA, DA, UA and TRP. Under the optimal conditions, MWCNs/MGF/GCE can simultaneously detect AA, DA, UA and TRP with high selectivity and sensitivity. The detection limits were 18.28 µmol L(-1), 0.06 µmol L(-1), 0.93 µmol L(-1) and 0.87 µmol L(-1), respectively. Moreover, the modified electrode exhibited excellent stability and reproducibility. Copyright © 2014. Published by Elsevier B.V.
Hydroxyapatite fiber reinforced poly(alpha-hydroxy ester) foams for bone regeneration
NASA Technical Reports Server (NTRS)
Thomson, R. C.; Yaszemski, M. J.; Powers, J. M.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
1998-01-01
A process has been developed to manufacture biodegradable composite foams of poly(DL-lactic-co-glycolic acid) (PLGA) and hydroxyapatite short fibers for use in bone regeneration. The processing technique allows the manufacture of three-dimensional foam scaffolds and involves the formation of a composite material consisting of a porogen material (either gelatin microspheres or salt particles) and hydroxyapatite short fibers embedded in a PLGA matrix. After the porogen is leached out, an open-cell composite foam remains which has a pore size and morphology defined by the porogen. By changing the weight fraction of the leachable component it was possible to produce composite foams with controlled porosities ranging from 0.47 +/- 0.02 to 0.85 +/- 0.01 (n = 3). Up to a polymer:fiber ratio of 7:6, short hydroxyapatite fibers served to reinforce low-porosity PLGA foams manufactured using gelatin microspheres as a porogen. Foams with a compressive yield strength up to 2.82 +/- 0.63 MPa (n = 3) and a porosity of 0.47 +/- 0.02 (n = 3) were manufactured using a polymer:fiber weight ratio of 7:6. In contrast, high-porosity composite foams (up to 0.81 +/- 0.02, n = 3) suitable for cell seeding were not reinforced by the introduction of increasing quantities of hydroxyapatite short fibers. We were therefore able to manufacture high-porosity foams which may be seeded with cells but which have minimal compressive yield strength, or low porosity foams with enhanced osteoconductivity and compressive yield strength.
Parmar, Paresh A.; St-Pierre, Jean-Philippe; Chow, Lesley W.; Puetzer, Jennifer L.; Stoichevska, Violet; Peng, Yong Y.; Werkmeister, Jerome A.; Ramshaw, John A. M.; Stevens, Molly M.
2017-01-01
Collagen I foams are used in the clinic as scaffolds to promote articular cartilage repair as they provide a bioactive environment for cells with chondrogenic potential. However, collagen I as a base material does not allow for precise control over bioactivity. Alternatively, recombinant bacterial collagens can be used as “blank slate” collagen molecules to offer a versatile platform for incorporation of selected bioactive sequences and fabrication into 3D scaffolds. Here, we show the potential of Streptococcal collagen-like 2 (Scl2) protein foams modified with peptides designed to specifically and noncovalently bind hyaluronic acid and chondroitin sulfate to improve chondrogenesis of human mesenchymal stem cells (hMSCs) compared to collagen I foams. Specific compositions of functionalized Scl2 foams lead to improved chondrogenesis compared to both nonfunctionalized Scl2 and collagen I foams, as indicated by gene expression, extracellular matrix accumulation, and compression moduli. hMSCs cultured in functionalized Scl2 foams exhibit decreased collagens I and X gene and protein expression, suggesting an advantage over collagen I foams in promoting a chondrocytic phenotype. These highly modular foams can be further modified to improve specific aspects chondrogenesis. As such, these scaffolds also have the potential to be tailored for other regenerative medicine applications. PMID:27219220
Preparation and characterization of starch-based loose-fill packaging foams
NASA Astrophysics Data System (ADS)
Fang, Qi
Regular and waxy corn starches were blended in various ratios with biodegradable polymers including polylactic acid (PLA), Eastar Bio Copolyester 14766 (EBC) and Mater-Bi ZF03U (MBI) and extruded with a C. W. Brabender laboratory twin screw extruder using a 3-mm die nozzle at 150°C and 150 rev/min. Physical characteristics including radial expansion, unit density and bulk density and water solubility index, water absorption characteristics, mechanical properties including compressibility, Young's modulus, spring index, bulk compressibility and bulk spring index and abrasion resistance were investigated as affected by the ingredient formulations, i.e. type of polymers, type of starches, polymer to starch ratio and starch moisture content. A completely randomized factorial blocking experimental design was used. Fifty-four treatments resulted. Each treatment was replicated three times. SAS statistical software package was used to analyze the data. Foams made of waxy starch had better radial expansion, lower unit density and bulk density than did foams made of regular starch. Regular starch foams had significantly lower water solubility index than did the waxy starch foams. PLA-starch foams had the lowest compressibility and Young's modulus. MBI-starch foams were the most rigid. All foams had excellent spring indices and bulk spring indices which were comparable to the spring index of commercial expanded polystyrene foam. Correlations were established between the foam mechanical properties and the physical characteristics. Foam compressibility and Young's modulus decreased as increases in radial expansion and decreases in unit and bulk densities. Their relationships were modeled with power law equations. No correlation was observed between spring index and bulk spring index and foam physical characteristics. MBI-starch foams had the highest equilibrium moisture content. EBC-starch and PLA-starch foams had similar water absorption characteristics. No significant difference existed in water absorption characteristics between foams made of regular and waxy starches. Empirical models were developed to correlate foam water absorption characteristics with relative humidity and polymer content. The developed models fit the data well with relatively small standard errors and uniformly scattered residual plots. Foams with higher polymer content had better abrasion resistance than did foams with lower polymer content.
Draelos, Zoe Diana; Elewski, Boni; Staedtler, Gerald; Havlickova, Blanka
2013-12-01
Rosacea is a common chronic inflammatory skin disease that primarily affects facial skin. Its etiology is unknown, and currently there is no cure. Rosacea can be associated with severe symptoms, including transient erythema (flushing), nontransient erythema, papules, pustules, and telangiectases, leading to substantial discomfort and an unattractive appearance. This randomized, double-blind, vehicle-controlled, multicenter, parallel-group study conducted over 12 weeks with a 4-week follow-up period evaluated the efficacy and safety of a new formulation of azelaic acid (AzA) foam in a 15% concentration compared to vehicle alone in patients with papulopustular rosacea (PPR). Primary efficacy variables assessed were investigator global assessment (IGA) dichotomized into success and failure, and nominal change in inflammatory lesion count from baseline to end of treatment. Results indicated that the new foam formulation of AzA is effective and well-tolerated in a population of patients with PPR. Although no single formulation is appropriate for all patients, the development of a new foam formulation in addition to other available vehicles provides patients with options and allows health care providers to match the needs as well as preferences of individual patients and skin types with appropriate delivery modalities.
Manguso, F; Balzano, A
2007-07-01
Beclomethasone dipropionate (BDP) is a second-generation steroid with topical effects and minimal systemic activity for patients with ulcerative colitis (UC). To review all available literature to assess the efficacy of enema/foam BDP compared with enema/foam 5-aminosalicylic acid (5-ASA) in the control of left-sided mild-moderate UC. We selected randomized controlled trials of enema/foam BDP compared with enema/foam 5-ASA treatment in patients with UC. Two reviewers assessed trial quality and extracted data independently. Four trials involving 428 UC patients, 209 treated with 5-ASA (1-4 g o.d.) and 219 with BDP (3 mg o.d.), were included. Intention-to-treat analysis showed that 5-ASA induced improvement/remission of UC in 146 (69.9%) patients, while BDP in 143 (65.3%). The test for heterogeneity (Cochran Q) was not significant and Mantel-Haenszel pooled estimate of odds ratio was 1.23 (95% CI = 0.82-1.85). The results did not change when analysis was performed on a per-protocol basis. The randomized controlled trials identified in this review showed that rectal BDP has equal effect as 5-ASA to control symptoms in UC.
α-TCP cements prepared by syringe-foaming: Influence of Na2HPO4 and surfactant concentration.
Vásquez, A F; Domínguez, S; Loureiro Dos Santos, L A
2017-12-01
The lack of intrinsic open porosity in calcium phosphate cements slows down the resorption rate and bone ingrowth when implanted In Vivo. In this study, macroporous structures were obtained by mixing α-TCP cement with a foamed liquid phase containing different concentrations of sodium hydrogen phosphate and a nonionic surfactant. The cement paste was prepared by hand mixing in a novel system of two syringes connected by a tube. Two different liquid to powder (L/P) ratios were used to prepare the cement paste. The cement samples showed open macropores with diameters>100μm. The specimens prepared with lower L/P ratio showed smaller porosity, macroporosity and pore size distribution. The cohesion of the cement paste in liquid solutions was assessed by adding 2wt% sodium alginate to the liquid phase. This study suggests that the final macrostructure of the foamed cements can be controlled by varying the phosphate and surfactant concentrations in the liquid phase and the L/P ratio. Copyright © 2017 Elsevier B.V. All rights reserved.
Nugroho, Aris W; Leadbeater, Garry; Davies, Ian J
2010-12-01
The authors have conducted a preliminary investigation with regard to the potential to manufacture porous titanium alloys for biomedical applications using toxic-free elemental powders, i.e., Ti, Nb, Ta, Zr, in combination with the pressurised gas bubble entrapment method and in contrast to standard processing routes that generally utilise prealloyed powder containing potentially toxic elements. Elemental powder compacts were either hot isostatic pressed (HIP-ed) at 1000°C and then foamed at 1150°C or else HIP-ed at 1100°C and foamed at 1350°C. Porous α + β alloys containing up to 45 vol% of porosity in the size range 20-200 μm were successfully produced, thus highlighting the potential of this manufacturing route. It was expected that further optimisation of the processing route would allow full development of the preferred β-Ti phase (from the point of view of elastic modulus compatibility between implant and bone) with this being the subject of future work by the authors.
Mechanically Robust, Ultraelastic Hierarchical Foam with Tunable Properties via 3D Printing
Chen, Qiyi; Cao, Peng-Fei; Advincula, Rigoberto C.
2018-04-11
We present a mechanically robust, ultraelastic foam with controlled multiscale architectures and tunable mechanical/conductive performance is fabricated via 3D printing. Hierarchical porosity, including both macro- and microscaled pores, are produced by the combination of direct ink writing (DIW), acid etching, and phase inversion. The thixotropic inks in DIW are formulated by a simple one-pot process to disperse duo nanoparticles (nanoclay and silica nanoparticles) in a polyurethane suspension. The resulting lightweight foam exhibits tailorable mechanical strength, unprecedented elasticity (standing over 1000 compression cycles), and remarkable robustness (rapidly and fully recover after a load more than 20 000 times of its ownmore » weight). Surface coating of carbon nanotubes yields a conductive elastic foam that can be used as piezoresistivity sensor with high sensitivity. For the first time, this strategy achieves 3D printing of elastic foam with controlled multilevel 3D structures and mechanical/conductive properties. In conclusion, the facile ink preparation method can be utilized to fabricate foams of various materials with desirable performance via 3D printing.« less
Mechanically Robust, Ultraelastic Hierarchical Foam with Tunable Properties via 3D Printing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Qiyi; Cao, Peng-Fei; Advincula, Rigoberto C.
We present a mechanically robust, ultraelastic foam with controlled multiscale architectures and tunable mechanical/conductive performance is fabricated via 3D printing. Hierarchical porosity, including both macro- and microscaled pores, are produced by the combination of direct ink writing (DIW), acid etching, and phase inversion. The thixotropic inks in DIW are formulated by a simple one-pot process to disperse duo nanoparticles (nanoclay and silica nanoparticles) in a polyurethane suspension. The resulting lightweight foam exhibits tailorable mechanical strength, unprecedented elasticity (standing over 1000 compression cycles), and remarkable robustness (rapidly and fully recover after a load more than 20 000 times of its ownmore » weight). Surface coating of carbon nanotubes yields a conductive elastic foam that can be used as piezoresistivity sensor with high sensitivity. For the first time, this strategy achieves 3D printing of elastic foam with controlled multilevel 3D structures and mechanical/conductive properties. In conclusion, the facile ink preparation method can be utilized to fabricate foams of various materials with desirable performance via 3D printing.« less
Ueno, Daisuke; Nakamura, Kei; Kojima, Kousuke; Toyoshima, Takeshi; Tanaka, Hideaki; Ueda, Kazuhiko; Koyano, Kiyoshi; Kodama, Toshiro
2018-04-01
Simultaneous vertical ridge augmentation (VRA) can reduce treatment procedures and surgery time, but the concomitant reduction in primary stability (PS) of a shallow-placed implant imparts risk to its prognosis. Although several studies have reported improvements in PS, there is little information from any simultaneous VRA model. This study aimed to evaluate whether tapered implants with stepwise under-prepared osteotomy could improve the PS of shallow-placed implants in an in vitro model of simultaneous VRA. Tapered implants (Straumann ® Bone Level Tapered implant; BLT) and hybrid implants (Straumann ® Bone Level implant; BL) were investigated in this study. A total of 80 osteotomies of different depths (4, 6, 8, 10 mm) were created in rigid polyurethane foam blocks, and each BLT and BL was inserted by either standard (BLT-S, BL-S) or a stepwise under-prepared (BLT-U, BL-U) osteotomy protocol. The PS was evaluated by measuring maximum insertion torque (IT), implant stability quotient (ISQ), and removal torque (RT). The significance level was set at P < 0.05. There were no significant differences in IT, ISQ or RT when comparing BLT-S and BL-S or BLT-U and BL-U at placement depths of 6 and 8 mm. When comparison was made between osteotomy protocols, IT was significantly greater in BLT-U than in BLT-S at all placement depths. A stepwise under-prepared osteotomy protocol improves initial stability of a tapered implant even in a shallow-placed implant model. BLT-U could be a useful protocol for simultaneous VRA.
Colloidal gas aphron foams: A novel approach to a hydrogel based tissue engineered myocardial patch
NASA Astrophysics Data System (ADS)
Johnson, Elizabeth Edna
Cardiovascular disease currently affects an estimated 58 million Americans and is the leading cause of death in the US. Over 2.3 million Americans are currently living with heart failure a leading cause of which is acute myocardial infarction, during which a part of the heart muscle is damaged beyond repair. There is a great need to develop treatments for damaged heart tissue. One potential therapy involves replacement of nonfunctioning scar tissue with a patch of healthy, functioning tissue. A tissue engineered cardiac patch would be ideal for such an application. Tissue engineering techniques require the use of porous scaffolds, which serve as a 3-D template for initial cell attachment and grow-th leading to tissue formation. The scaffold must also have mechanical properties closely matching those of the tissues at the site of implantation. Our research presents a new approach to meet these design requirements. A unique interaction between poly(vinyl alcohol) and amino acids has been discovered by our lab, resulting in the production of novel gels. These unique synthetic hydrogels along with one natural hydrogel, alginate (derived from brown seaweed), have been coupled with a new approach to tissue scaffold fabrication using solid colloidal gas aphrons (CGAs). CGAs are colloidal foams containing uniform bubbles with diameters on the order of micrometers. Upon solidification the GCAs form a porous, 3-D network suitable for a tissue scaffold. The project encompasses four specific aims: (I) characterize hydrogel formation mechanism, (II) use colloidal gas aphrons to produce hydrogel scaffolds, (III) chemically and physically characterize scaffold materials and (IV) optimize and evaluate scaffold biocompatibility.
Turan, Erkut; Gules, Ozay; Kilimci, Figen Sevil; Kara, Mehmet Erkut; Dilek, Omer Gurkan; Sabanci, Seyyid Said; Tatar, Musa
2017-01-01
The present study investigates the efficiency of liquid foam soap, ethanol, citric acid and benzalkonium chloride as a fixative-preservative solution (a soap-and ethanol-based fixing solution, or SEFS). In this study, ethanol serves as the fixative and preservative, liquid foam soap as the modifying agent, citric acid as the antioxidant and benzalkonium chloride as the disinfectant. The goat cadavers perfused with SEFS (n=8) were evaluated over a period of one year with respect to hardness, colour and odour using objective methods. Colour and hardness were compared between one fresh cadaver and the SEFS-embalmed cadavers. Histological and microbiological examinations were also performed in tissue samples. Additionally, the cadavers were subjectively evaluated after dissection and palpation. The SEFS provided the effectiveness expected over a 1-year embalming period for the animal cadavers. No bacteria or fungi were isolated except for some non-pathogenic Bacillus species. Visible mould was not present on either cadavers or in the surrounding environment. The cadavers maintained an appearance close to their original anatomical appearance, with muscles having good hardness and elasticity for dissection. Copyright © 2016 Elsevier GmbH. All rights reserved.
Lubin, Judith; Hernandez, Maria A; Drukteinis, Saulius E; Parker, William B; Murray, Peter E
2014-08-01
To evaluate the effectiveness of 4 procedures to disinfect implant surfaces intentionally inoculated with bacteria and afterward to evaluate osteoblast viability to the disinfected implant surfaces. Eighty-eight commercially pure Osseotite and Nanotite titanium implant discs were inoculated with Porphyromonas gingivalis. The implant surfaces were disinfected with EDTA, tetracycline, citric acid, or neodymium-doped yttrium aluminum garnet (Nd:YAG) laser. The implant discs were then placed in cultures of osteoblast cells. Osseotite implant discs were easier to disinfect compared with the Nanotite implant discs. Citric acid and tetracycline were the most effective solutions for the disinfection of P. gingivalis from the Osseotite implant discs. The Nanotite implant discs were the most difficult to disinfect, likely because of their chemical and physical properties. Citric acid and tetracycline were most effective for disinfecting the Osseotite implant discs, and further clinical research is needed to verify these effects in vivo. The Nd:YAG laser was the weakest disinfection method, and it is not recommended for disinfecting implant surfaces until its effectiveness is improved.
Saksø, H; Jakobsen, T; Saksø, M; Baas, J; Jakobsen, Ss; Soballe, K
2013-01-01
Implant surface treatments that improve early osseointegration may prove useful in long-term survival of uncemented implants. We investigated Acid Etching and Plasma Cleaning on titanium implants. In a randomized, paired animal study, four porous coated Ti implants were inserted into the femurs of each of ten dogs. PC (Porous Coating; control)PC+PSHA (Plasma Sprayed Hydroxyapatite; positive control)PC+ET (Acid Etch)PC+ET+PLCN (Plasma Cleaning) After four weeks mechanical fixation was evaluated by push-out test and osseointegration by histomorphometry. The PSHA-coated implants were better osseointegrated than the three other groups on outer surface implant porosity (p<0.05) while there was no statistical difference in deep surface implant porosity when compared with nontreated implant. Within the deep surface implant porosity, there was more newly formed bone in the control group compared to the ET and ET+PCLN groups (p<0.05). In all compared groups, there was no statistical difference in any biomechanical parameter. In terms of osseointegration on outer surface implant porosity PC+PSHA was superior to the other three groups. Neither the acid etching nor the plasma cleaning offered any advantage in terms of implant osseointegration. There was no statistical difference in any of the biomechanical parameters among all groups in the press-fit model at 4 weeks of evaluation time.
Forming and Bending of Metal Foams
NASA Astrophysics Data System (ADS)
Nebosky, Paul; Tyszka, Daniel; Niebur, Glen; Schmid, Steven
2004-06-01
This study examines the formability of a porous tantalum foam, known as trabecular metal (TM). Used as a bone ingrowth surface on orthopedic implants, TM is desirable due to its combination of high strength, low relative density, and excellent osteoconductive properties. This research aims to develop bend and stretch forming as a cost-effective alternative to net machining and EDM for manufacturing thin parts made of TM. Experimentally, bending about a single axis using a wiping die was studied by observing cracking and measuring springback. It was found that die radius and clearance strongly affect the springback properties of TM, while punch speed, embossings, die radius and clearance all influence cracking. Depending on the various combinations of die radius and clearance, springback factor ranged from .70-.91. To examine the affect of the foam microstructure, bending also was examined numerically using a horizontal hexagonal mesh. As the hexagonal cells were elongated along the sheet length, elastic springback decreased. This can be explained by the earlier onset of plastic hinging occurring at the vertices of the cells. While the numerical results matched the experimental results for the case of zero clearance, differences at higher clearances arose due to an imprecise characterization of the post-yield properties of tantalum. By changing the material properties of the struts, the models can be modified for use with other open-cell metallic foams.
Improving foaming properties of yolk-contaminated egg albumen by basic soy protein.
Wang, Guang; Wang, Tong
2009-10-01
Yolk contamination of egg white is a common problem in the egg breaking industry. Foaming properties of egg white protein are affected by such contamination, but proteins of basic nature may restore the foaming properties of the yolk-contaminated egg white protein. The purpose of this study was to chemically modify a soy protein, that is, to esterify the acidic groups on the protein and to study the potential of such modified protein in improving foaming. We showed that the modification changed the isoelectric point of soy protein isolate (SPI) from 4.5 to about 10. Sonication was proven to be a very effective means to redisperse the methanol-denatured soy protein during reaction, as shown by the improved solubility profile. Such modified basic protein, that is, the sonicated-modified SPI (SMSPI), when added to the yolk-contaminated (at 0.4% level, as-is basis) egg white, gave significantly improved foaming properties. We have shown that the slight change in pH due to the addition of SMSPI was not the reason for improved foaming performance; instead, the modified protein itself was the main reason for such improvement. Addition of SMSPI increased the foaming performance of both pure egg white and yolk-contaminated egg white. SMSPI consistently performed better than the unmodified SPI for improving foaming. Addition of SMSPI (16%, based on dry egg white, and 1.6% based on liquid egg white) fully restored foam expansion and foam liquid stability of 0.4% yolk-contaminated egg white, and it even out-performed the foaming of pure white protein. Therefore, a feasible solution to restore the foaming properties of yolk-contaminated egg white has been identified. It is expected that such modified SPI can be used as an additive or ingredient in foaming formulation, especially when the egg white protein is suspected of lipid contamination.
NF-κB inhibitors that prevent foam cell formation and atherosclerotic plaque accumulation.
Plotkin, Jesse D; Elias, Michael G; Dellinger, Anthony L; Kepley, Christopher L
2017-08-01
The transformation of monocyte-derived macrophages into lipid-laden foam cells is one inflammatory process underlying atherosclerotic disease. Previous studies have demonstrated that fullerene derivatives (FDs) have inflammation-blunting properties. Thus, it was hypothesized that FD could inhibit the transformation process underlying foam cell formation. Fullerene derivatives inhibited the phorbol myristic acid/oxidized low-density lipoprotein-induced differentiation of macrophages into foam cells as determined by lipid staining and morphology.Lipoprotein-induced generation of TNF-α, C5a-induced MC activation, ICAM-1 driven adhesion, and CD36 expression were significantly inhibited in FD treated cells compared to non-treated cells. Inhibition appeared to be mediated through the NF-κB pathway as FD reduced expression of NF-κB and atherosclerosis-associated genes. Compared to controls, FD dramatically inhibited plaque formation in arteries of apolipoprotein E null mice. Thus, FD may be an unrecognized therapy to prevent atherosclerotic lesions via inhibition of foam cell formation and MC stabilization. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Rabeeh, Bakr Mohamed
Great efforts aiming towards the synthesis and the development of structural composite materials. Direct metal oxidation, DIMOX introduced for hybrid composite processing. However, oxidation temperatures around 1100°C lead to the formation of porous ceramic materials. To utilize this porosity intentionally for foam production, a new approach based on synergetic effect of alloying elements, DIMOX and semisolid (rheocsting) processing is developed. A semisolid reaction, rheocasting is introduced to control porosity shape and size. Aluminum alloy 6xxx (automobile scrap pistons) is recycled for this objective and DIMOX at 1100°C for 30 min, then rheocasting, at 750°C for 30 minutes. The effect of α-Fe powder, Mg powder, and Boric acid powder established for the objective of a hybrid structural metal matrix composite in bulk foam matrix. The kinetic of formation of hybrid metal matrix foam composite is introduced. Microstructural and mechanical characterization established for high performance Aluminum foam hybrid composite materials.
Yu, Cuiping; Cha, Yue; Wu, Fan; Xu, Xianbing; Du, Ming
2018-03-22
In this study, the effects of limited hydrolysis and/or high-pressure homogenization (HPH) treatment in acid conditions on the functional properties of oyster protein isolates (OPI) were studied. Protein solubility, surface hydrophobicity, particle size distribution, zeta potential, foaming, and emulsifying properties were evaluated. The results showed that acid treatment led to the dissociation and unfolding of OPI. Subsequent treatment such as limited proteolysis, HPH, and their combination remarkably improved the functional properties of OPI. Acid treatment produced flexible aggregates, as well as reduced particle size and solubility. On the contrary, limited hydrolysis increased the solubility of OPI. Furthermore, HPH enhanced the effectiveness of the above treatments. The emulsifying and foaming properties of acid- or hydrolysis-treated OPI significantly improved. In conclusion, a combination of acid treatment, limited proteolysis, and HPH improved the functional properties of OPI. The improvements in the functional properties of OPI could potentiate the use of oyster protein and its hydrolysates in the food industry.
The development of a composite bone model for training on placement of dental implants
Alkhodary, Mohamed Ahmed; Abdelraheim, Abdelraheim Emad Eldin; Elsantawy, Abd Elaleem Hassan; Al Dahman, Yousef Hamad; Al-Mershed, Mohammed
2015-01-01
Objectives It takes a lot of training on patients for both undergraduate to develop clinical sense as regards to the placement of dental implants in the jaw bones, also, the models provided by the dental implant companies for training are usually made of strengthened synthetic foams, which are far from the composition, and tactile sense provided by natural bone during drilling for clinical placement of dental implants. Methodology This is an in-vitro experimental study which utilized bovine femur bone, where the shaft of the femur provided the surface compact layer, and the head provided the cancellous bone layer, to provide a training model similar to jaw bones macroscopic anatomy. Both the compact and cancellous bone samples were characterized using mechanical compressive testing. Results The elastic moduli of the cancellous and cortical femur bone were comparable to those of the human mandible, and the prepared training model provided a more lifelike condition during the drilling and placement of dental implants. Conclusion The composite bone model developed simulated the macroscopic anatomy of the jaw bones having a surface layer of compact bone, and a core of cancellous bone, and provided a better and a more natural hands-on experience for placement of dental implants as compared to plastic models made of polyurethane. PMID:26309434
The development of a composite bone model for training on placement of dental implants.
Alkhodary, Mohamed Ahmed; Abdelraheim, Abdelraheim Emad Eldin; Elsantawy, Abd Elaleem Hassan; Al Dahman, Yousef Hamad; Al-Mershed, Mohammed
2015-04-01
It takes a lot of training on patients for both undergraduate to develop clinical sense as regards to the placement of dental implants in the jaw bones, also, the models provided by the dental implant companies for training are usually made of strengthened synthetic foams, which are far from the composition, and tactile sense provided by natural bone during drilling for clinical placement of dental implants. This is an in-vitro experimental study which utilized bovine femur bone, where the shaft of the femur provided the surface compact layer, and the head provided the cancellous bone layer, to provide a training model similar to jaw bones macroscopic anatomy. Both the compact and cancellous bone samples were characterized using mechanical compressive testing. The elastic moduli of the cancellous and cortical femur bone were comparable to those of the human mandible, and the prepared training model provided a more lifelike condition during the drilling and placement of dental implants. The composite bone model developed simulated the macroscopic anatomy of the jaw bones having a surface layer of compact bone, and a core of cancellous bone, and provided a better and a more natural hands-on experience for placement of dental implants as compared to plastic models made of polyurethane.
Azelaic Acid Topical Formulations: Differentiation of 15% Gel and 15% Foam.
Del Rosso, James Q
2017-03-01
In this article, the author reviews topical formulations of azelaic acid used to treat papulopustular rosacea. Emphasis is placed on differences in vehicle technology and potential clinical impact of the possibility for neurosensory cutaneous tolerability reactions.
3D Printing Variable Stiffness Foams Using Viscous Thread Instability
NASA Astrophysics Data System (ADS)
Lipton, Jeffrey I.; Lipson, Hod
2016-08-01
Additive manufacturing of cellular structures has numerous applications ranging from fabrication of biological scaffolds and medical implants, to mechanical weight reduction and control over mechanical properties. Various additive manufacturing processes have been used to produce open regular cellular structures limited only by the resolution of the printer. These efforts have focused on printing explicitly designed cells or explicitly planning offsets between strands. Here we describe a technique for producing cellular structures implicitly by inducing viscous thread instability when extruding material. This process allows us to produce complex cellular structures at a scale that is finer than the native resolution of the printer. We demonstrate tunable effective elastic modulus and density that span two orders of magnitude. Fine grained cellular structures allow for fabrication of foams for use in a wide range of fields ranging from bioengineering, to robotics to food printing.
Salah, E O Mahgoub; Hayat, Z E Elbashir
2009-05-01
Seeds of an inbred line (B-11-90) of Karkadeh (Hibiscus sabdariffa) were investigated for their proximate composition (AOAC methods), nitrogen solubility and protein isolate (Karkadeh seed protein isolates [KSPI]) functional properties (standard methods). The fat and protein contents of the seeds were 22.43% and 32.46%, respectively. Nitrogen solubility was good in both water and 1.0 M NaCl at alkaline pH rather than at acidic pH, with better solubility at higher pH levels in water than in 1.0 M NaCl. The functional properties of the KSPI were as follows: water absorption capacity, 181 ml/100 g; fat absorption capacity, 110 ml/100 g; bulk density, 0.77 g/ml; and apparent viscosity (at 20 degrees C), 13.42 cps. KSPI showed a maximum foaming capacity at pH 12 and 1.6 M NaCl, a maximum emulsification capacity at pH 11 and 1.8 M NaCl, and a weaker foam stability at neutral pH than at acidic or alkaline pH, with a better foam stability at alkaline pH. The foam stability was considerably improved by treatment with 1.6 M NaCl.
Azelaic Acid Topical Formulations: Differentiation of 15% Gel and 15% Foam
2017-01-01
In this article, the author reviews topical formulations of azelaic acid used to treat papulopustular rosacea. Emphasis is placed on differences in vehicle technology and potential clinical impact of the possibility for neurosensory cutaneous tolerability reactions. PMID:28360967
Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants.
Kim, Ho-Young; Kim, Sang-Cheol
2016-11-01
The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group ( p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased ( p < 0.05), but was increased in the etched group ( p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks ( p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity.
Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants
Kim, Ho-Young
2016-01-01
Objective The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. Methods Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Results The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group (p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased (p < 0.05), but was increased in the etched group (p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks (p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. Conclusions Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity. PMID:27896213
Growth of carbon nanofibers using resol-type phenolic resin and cobalt(II) catalyst.
Kim, Taeyun; Mees, Karina; Park, Ho-Seon; Willert-Porada, Monika; Lee, Chang-Seop
2013-11-01
This study investigated carbon nanofibers (CNFs) grown on reticulated vitreous carbon (RVC) foam through catalytic deposition of ethylene. Before growing the CNFs, Co(II) on the RVC foam was expected to act as a catalyst by deposition. The preparation of the CNFs was a two-step process. The first step was preparing the RVC from polyurethane (PU) foam. Changes in weight over time were evaluated using two kinds of resol. The change in the mass and state of the sample with the change in temperature was studied during the carbonization process. The second step was to prepare the CNFs. An OH group was attached by the oxidation of the RVC foam. A change in the shape and mass of the sample was observed due to a change in nitric acid concentration and oxidation time. Then, cobalt was deposited to grow CNFs on the RVC foam. Hydrolysis helped to deposit the Co(ll) on the RVC foam. The appropriate time and temperature were investigated for the reduction process. In the last step, CNFs were prepared by the introducing ethylene gas. The resulting samples were analyzed using scanning electron microscopy, energy dispersive spectroscopy, N2-sorption, and X-ray photoelectron spectroscopy.
NASA Astrophysics Data System (ADS)
Guo, Meisong; Cheng, Yu; Yu, Yanan; Hu, Jingbo
2017-09-01
Proton exchange membrane (PEM) fuel cells have drawn a great deal of attention due to the rapidly growing energy consumption. Recently, Ni- and Co-based materials have been considered as promising electorcatalysts owing to their multi-functionality. In this work, Ni and Co nanoparticles are directly immobilized on a three-dimensional Ni foam substrate (Ni-Co/NF) without any conductive agents or polymer binder by a facile ion implantation method. The structure and morphology of the Ni-Co/NF electrode were characterized by scanning electron microscopy, powder X-ray diffraction, and X-ray photoelectron spectroscopy. The performance of the Ni-Co/NF electrode in the electrochemical oxidation of NaBH4 is investigated by cyclic voltammetry and chronoamperometry. The Ni-Co/NF electrode exhibited excellent electrocatalytic activity and good stability during electrochemical reactions. These properties are attributed to the 3D porous structure of the Ni foam and the synergistic effect of Ni and Co nanoparticles. The enhanced electrocatalytic performance in NaBH4 electrooxidation compared with either Ni or Co nanoparticles alone suggests that the Ni-Co/NF is promising for fuel cell applications.
Petrovski, Steve; Tillett, Daniel; Seviour, Robert J
2012-01-01
Activated sludge plants suffer frequently from the operational problem of stable foam formation on aerobic reactor surfaces, which can be difficult to prevent. Many foams are stabilized by mycolic acid-containing Actinobacteria, the mycolata. The in situ biocontrol of foaming using phages is an attractive strategy. We describe two polyvalent phages, GTE5 and GRU1, targeting Gordonia terrae and Gordonia rubrupertincta, respectively, isolated from activated sludge. Phage GRU1 also propagates on Nocardia nova. Both phages belong to the family Siphoviridae and have similar-size icosahedral heads that encapsulate double-stranded DNA genomes (∼65 kb). Their genome sequences are similar to each other but markedly different from those of other sequenced phages. Both are arranged in a modular fashion. These phages can reduce or eliminate foam formation by their host cells under laboratory conditions.
Are extrusive rhyolites produced from permeable foam eruptions?
Friedman, I.
1989-01-01
The permeable foam hypothesis is suggested by Eichelberger el al. (1986) to explain a major loss of water from rhyolithic magmas in the volcanic conduit. Evidence for the high-water content of the major portion of the magmas is herein examined and rejected. Eichelberger's hypothesis does not take into account the large (~2 orders of magnitude) viscosity change that would occur in the conduit as a result of water loss. It also requires that the permeable foam collapse and weld to form an obsidian that in thin section displays no evidence of the foam. An alternate hypothesis to explain the existence of small amounts of high water content rhyolite glasses in acid volcanoes is that rhyolite magmas are relatively dry (0.1-0.3% H2O) and that water enters the magma from the environment to produce a water-rich selvage which then is kneaded into the body of the magma. -Author
Hirata, Yoshihiko; Ryu, Mizuyuki; Igarashi, Keisuke; Nagatsuka, Asami; Furuta, Taro; Kanaya, Shigenori; Sugiura, Masaki
2009-01-01
Sophorolipids (SLs) naturally produced from Candida bombicola are a mixture of lactonic (SL-lactone) and acidic (SL-acid) sophorosides of 17-L-hydroxydecanoic acid with an SL-lactone:SL-acid ratio of 72:28. SLs are biodegradable low-foaming surfactants with high detergency and hardness-tolerance properties. To analyze the effect of the SL-lactone:SL-acid ratio on these properties, SL-LXs containing X% SL-lactone, in which X varied from 0 to 100, were prepared and their interfacial activities and cytotoxicities examined. The minimum surface tension values for all SLs examined were comparable. The critical micelle concentration (CMC) was 680 mg/L for SL-L0 and 62-110 mg/L for the other SLs. Interestingly, natural SL (SL-L72) had the lowest surface tension and CMC among all of the SLs examined. The foaming ability and stability of the SLs were dependent on the SL-L content. SL-L0 and L17 had higher foaming values than the other SLs examined in 0-ppm hardness water. These values greatly reduced and became constant when the SL-L content increased over 55%. The detergencies of all of the SLs examined were comparable, except for those of SL-L0 and SL-L100, which were slightly lower than those of the other SLs. These results suggest that natural synergism between SLs creates a better balance for many interfacial activities. The cytotoxicity of SL-L72 was higher than that of SL-L0, but was comparable to that of surfactin, which is commercially available for cosmetic use. The low cytotoxicities and high interfacial properties of SLs increase their usefulness as biocompatible surface active agents for many applications.
2017-01-01
Poly- and perfluoroalkyl substances (PFASs) have been detected in an increasing number of water supplies. In many instances, the contamination is associated with the use of PFAS-containing aqueous film-forming foams (AFFF) in firefighting activities. To investigate the potential for remediating AFFF contamination in groundwater with heat-activated persulfate, PFAS oxidation and the generation of transformation products was evaluated under well-controlled conditions. Fluorotelomer- and perfluoroalkyl sulfonamide-based polyfluorinated compounds were transformed to perfluorinated carboxylic acids, which underwent further degradation under acidic conditions produced after persulfate decomposed. The presence of aquifer sediments decreased the efficiency of the remedial process but did not alter the transformation pathways. At high concentrations, the presence of organic solvents, such as those present in AFFF formulations, inhibited transformation of a representative perfluorinated compound, perfluorooctanoic acid. Heat-activated persulfate did not transform perfluorooctanesulfonic acid or perfluorohexanesulfonic acid under any conditions. Despite challenges associated with the creation of acidic conditions in the subsurface, the potential for generation of undesirable transformation products, and the release of toxic metals, heat-activated persulfate may be a useful in situ treatment for sites contaminated with polyfluoroalkyl substances and perfluorocarboxylic acids. PMID:29164864
3D Printing Variable Stiffness Foams Using Viscous Thread Instability
Lipton, Jeffrey I.; Lipson, Hod
2016-01-01
Additive manufacturing of cellular structures has numerous applications ranging from fabrication of biological scaffolds and medical implants, to mechanical weight reduction and control over mechanical properties. Various additive manufacturing processes have been used to produce open regular cellular structures limited only by the resolution of the printer. These efforts have focused on printing explicitly designed cells or explicitly planning offsets between strands. Here we describe a technique for producing cellular structures implicitly by inducing viscous thread instability when extruding material. This process allows us to produce complex cellular structures at a scale that is finer than the native resolution of the printer. We demonstrate tunable effective elastic modulus and density that span two orders of magnitude. Fine grained cellular structures allow for fabrication of foams for use in a wide range of fields ranging from bioengineering, to robotics to food printing. PMID:27503148
Elizondo Luna, Erardo M.; Barari, Farzad; Woolley, Robert; Goodall, Russell
2014-01-01
Metal foams are interesting materials from both a fundamental understanding and practical applications point of view. Uses have been proposed, and in many cases validated experimentally, for light weight or impact energy absorbing structures, as high surface area heat exchangers or electrodes, as implants to the body, and many more. Although great progress has been made in understanding their structure-properties relationships, the large number of different processing techniques, each producing material with different characteristics and structure, means that understanding of the individual effects of all aspects of structure is not complete. The replication process, where molten metal is infiltrated between grains of a removable preform material, allows a markedly high degree of control and has been used to good effect to elucidate some of these relationships. Nevertheless, the process has many steps that are dependent on individual “know-how”, and this paper aims to provide a detailed description of all stages of one embodiment of this processing method, using materials and equipment that would be relatively easy to set up in a research environment. The goal of this protocol and its variants is to produce metal foams in an effective and simple way, giving the possibility to tailor the outcome of the samples by modifying certain steps within the process. By following this, open cell aluminum foams with pore sizes of 1–2.36 mm diameter and 61% to 77% porosity can be obtained. PMID:25548938
Gannasin, Sri Puvanesvari; Adzahan, Noranizan Mohd; Mustafa, Shuhaimi; Muhammad, Kharidah
2016-04-01
Hydrocolloids were extracted from seed mucilage and the pulp fractions from red tamarillo (Solanum betaceum Cav.) mesocarp, and characterisation of their techno-functional properties and in vitro bile acid-binding capacities was performed. The seed mucilage hydrocolloids that were extracted, using either 1% citric acid (THC) or water (THW), had a good foaming capacity (32-36%), whereas the pulp hydrocolloids that were extracted, using 72% ethanol (THE) or 20mM HEPES buffer (THH), had no foaming capacity. The pulp hydrocolloid, however, possessed high oil-holding and water-holding capacities in the range of 3.3-3.6 g oil/g dry sample and 25-27 g water/g dry sample, respectively. This enabled the pulp hydrocolloid to entrap more bile acids (35-38% at a hydrocolloid concentration of 2%) in its gelatinous network in comparison to commercial oat fibre and other hydrocolloids studied. The exceptional emulsifying properties (80-96%) of both hydrocolloids suggest their potential applications as food emulsifiers and bile acid binders. Copyright © 2015 Elsevier Ltd. All rights reserved.
An, Dong; Hao, Feng; Zhang, Fuqiang; Kong, Wei; Chun, Jerold; Xu, Xuemin; Cui, Mei-Zhen
2017-09-01
Macrophage uptake of oxidized low-density lipoprotein (oxLDL) plays an important role in foam cell formation and the pathogenesis of atherosclerosis. We report here that lysophosphatidic acid (LPA) enhances lipopolysaccharide (LPS)-induced oxLDL uptake in macrophages. Our data revealed that both LPA and LPS highly induce the CD14 expression at messenger RNA and protein levels in macrophages. The role of CD14, one component of the LPS receptor cluster, in LPA-induced biological functions has been unknown. We took several steps to examine the role of CD14 in LPA signaling pathways. Knockdown of CD14 expression nearly completely blocked LPA/LPS-induced oxLDL uptake in macrophages, demonstrating for the first time that CD14 is a key mediator responsible for both LPA- and LPS-induced oxLDL uptake/foam cell formation. To determine the molecular mechanism mediating CD14 function, we demonstrated that both LPA and LPS significantly induce the expression of scavenger receptor class A type I (SR-AI), which has been implicated in lipid uptake process, and depletion of CD14 levels blocked LPA/LPS-induced SR-AI expression. We further showed that the SR-AI-specific antibody, which quenches SR-AI function, blocked LPA- and LPS-induced foam cell formation. Thus, SR-AI is the downstream mediator of CD14 in regulating LPA-, LPS-, and LPA/LPS-induced foam cell formation. Taken together, our results provide the first experimental evidence that CD14 is a novel connecting molecule linking both LPA and LPS pathways and is a key mediator responsible for LPA/LPS-induced foam cell formation. The LPA/LPS-CD14-SR-AI nexus might be the new convergent pathway, contributing to the worsening of atherosclerosis. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.
Gao, Li-Na; Zhou, Xin; Lu, Yu-Ren; Li, Kefeng; Gao, Shan; Yu, Chun-Quan; Cui, Yuan-Lu
2018-01-01
Atherosclerosis is the major worldwide cause of mortality for patients with coronary heart disease. Many traditional Chinese medicine compound prescriptions for atherosclerosis treatment have been tried in patients. Dan-Lou prescription, which is improved from Gualou-Xiebai-Banxia decoction, has been used to treat chest discomfort (coronary atherosclerosis) for approximately 2,000 years in China. Although the anti-inflammatory activities of Dan-Lou prescription have been proposed previously, the mechanism remains to be explored. Based on the interaction between inflammation and atherosclerosis, we further investigated the effect of Dan-Lou prescription on macrophage-derived foam cell formation and disclosed the underlying mechanisms. In the oxidative low-density lipoprotein (ox-LDL) induced foam cells model using murine macrophage RAW 264.7 cells, the ethanol extract from Dan-Lou prescription (EEDL) reduced ox-LDL uptake and lipid deposition by inhibiting the protein and mRNA expression of Toll-like receptor (TLR)4 and scavenger receptor (SR)B1. After stimulation with ox-LDL, the metabolic profile of macrophages was also changed, while the intervention of the EEDL mainly regulated the metabolism of isovalerylcarnitine, arachidonic acid, cholesterol, aspartic acid, arginine, lysine, L-glutamine and phosphatidylethanolamine (36:3), which participated in the regulation of the inflammatory response, lipid accumulation and cell apoptosis. In total, 27 inflammation-related gene targets were screened, and the biological mechanisms, pathways and biological functions of the EEDL on macrophage-derived foam cells were systemically analyzed by Ingenuity Pathway Analysis system (IPA). After verification, we found that EEDL alleviated ox-LDL induced macrophage foam cell formation by antagonizing the mRNA and protein over-expression of PPARγ, blocking the phosphorylation of IKKα/β, IκBα and NF-κB p65 and maintaining the expression balance between Bax and Bcl-2. In conclusion, we provided evidences that Dan-Lou prescription effectively attenuated macrophage foam cell formation via the TLR4/NF-κB and PPARγ signaling pathways.
Yagoub, Abu El-Gasim A; Mohamed, Babiker E; Ahmed, Abdel Halim R; El Tinay, Abdullahi H
2004-10-06
Furundu, a meat substitute, is traditionally prepared by cooking the karkade (Hibiscus sabdariffa L.) seed and then fermenting it for 9 days. Physicochemical and functional properties of raw and cooked seed and of furundu ferments were analyzed. Furundu preparation resulted in significant changes in karkade seed major nutrients. Total polyphenols and phytic acid were also reduced. The increase in total acidity and fat acidity coupled with a decrease in pH indicates microbial hydrolysis of the major nutrients; proteins, carbohydrates, and fats. In vitro digestibility of the seed proteins reached the maximum value (82.7%) at the sixth day of fermentation, but thereafter it significantly decreased. The effect of furundu preparation on N solubility profiles and functional properties, such as emulsification and foaming properties and other related parameters, is investigated in water and in 1 M NaCl extracts from defatted flour samples. The results show that cooking followed by fermentation affects proteins solubility in water and 1 M NaCl. The foaming capacity (FC) from the flour of raw seed decreased as a result of cooking. Fermentation for 9 days significantly increased the FC of the cooked seed, restoring the inherent value. Foam from fermented samples collapsed more rapidly during a period of 120 min as compared to the foam from raw and cooked karkade seeds; stability in 1 M NaCl was lower as compared to those in water. In water, the emulsion stability (ES) from the fermented samples was significantly higher than that of the raw seed flour. Addition of 1 M NaCl significantly decreased the ES of the fermented samples.
Removal of Mercury by Foam Fractionation Using Surfactin, a Biosurfactant
Chen, Hau-Ren; Chen, Chien-Cheng; Reddy, A. Satyanarayana; Chen, Chien-Yen; Li, Wun Rong; Tseng, Min-Jen; Liu, Hung-Tsan; Pan, Wei; Maity, Jyoti Prakash; Atla, Shashi B.
2011-01-01
The separation of mercury ions from artificially contaminated water by the foam fractionation process using a biosurfactant (surfactin) and chemical surfactants (SDS and Tween-80) was investigated in this study. Parameters such as surfactant and mercury concentration, pH, foam volume, and digestion time were varied and their effects on the efficiency of mercury removal were investigated. The recovery efficiency of mercury ions was highly sensitive to the concentration of the surfactant. The highest mercury ion recovery by surfactin was obtained using a surfactin concentration of 10 × CMC, while recovery using SDS required < 10 × CMC and Tween-80 >10 × CMC. However, the enrichment of mercury ions in the foam was superior with surfactin, the mercury enrichment value corresponding to the highest metal recovery (10.4%) by surfactin being 1.53. Dilute solutions (2-mg L−1 Hg2+) resulted in better separation (36.4%), while concentrated solutions (100 mg L−1) enabled only a 2.3% recovery using surfactin. An increase in the digestion time of the metal solution with surfactin yielded better separation as compared with a freshly-prepared solution, and an increase in the airflow rate increased bubble production, resulting in higher metal recovery but low enrichment. Basic solutions yielded higher mercury separation as compared with acidic solutions due to the precipitation of surfactin under acidic conditions. PMID:22174661
Removal of mercury by foam fractionation using surfactin, a biosurfactant.
Chen, Hau-Ren; Chen, Chien-Cheng; Reddy, A Satyanarayana; Chen, Chien-Yen; Li, Wun Rong; Tseng, Min-Jen; Liu, Hung-Tsan; Pan, Wei; Maity, Jyoti Prakash; Atla, Shashi B
2011-01-01
The separation of mercury ions from artificially contaminated water by the foam fractionation process using a biosurfactant (surfactin) and chemical surfactants (SDS and Tween-80) was investigated in this study. Parameters such as surfactant and mercury concentration, pH, foam volume, and digestion time were varied and their effects on the efficiency of mercury removal were investigated. The recovery efficiency of mercury ions was highly sensitive to the concentration of the surfactant. The highest mercury ion recovery by surfactin was obtained using a surfactin concentration of 10 × CMC, while recovery using SDS required < 10 × CMC and Tween-80 >10 × CMC. However, the enrichment of mercury ions in the foam was superior with surfactin, the mercury enrichment value corresponding to the highest metal recovery (10.4%) by surfactin being 1.53. Dilute solutions (2-mg L(-1) Hg(2+)) resulted in better separation (36.4%), while concentrated solutions (100 mg L(-1)) enabled only a 2.3% recovery using surfactin. An increase in the digestion time of the metal solution with surfactin yielded better separation as compared with a freshly-prepared solution, and an increase in the airflow rate increased bubble production, resulting in higher metal recovery but low enrichment. Basic solutions yielded higher mercury separation as compared with acidic solutions due to the precipitation of surfactin under acidic conditions.
Trona-enhanced steam foam oil recovery process
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lau, H.C.
1988-03-01
In a process in which steam and steam-foaming surfactant are injected into a subterranean reservoir for displacing a relatively acidic oil toward a production location, which process includes injecting into the reservoir, at least as soon as at least some portion of the steam is injected, (a) a kind and amount of water soluble, alkaline material effective for ion-exchanging multivalent ions from the reservoir rocks and precipitating compounds containing those ions and for causing the aqueous liquid phase of the injected fluid to form soaps of substantially all of the petroleum acids in the reservoir oil, and (b) at leastmore » one surfactant arranged for foaming the steam and providing a preformed cosurfactant material capable of increasing the salinity requirement of an aqueous surfactant system in which soaps derived from the reservoir oil comprise a primary surfactant, an improvement is described comprising: using as the water soluble alkaline material, a material consisting essentially of a substantially equal molar mixture of alkali metal carbonates and bicarbonates which is, or is substantially equivalent to, trona.« less
Gil, Francisco Javier; Aparicio, Conrado; Manero, Jose M; Padros, Alejandro
2009-01-01
This study evaluated the effect of external hexagon height and commonly applied surface treatments on the fatigue life of titanium dental implants. Electropolished commercially pure titanium dental implants (seven implants per group) with three different external hexagon heights (0.6, 1.2, and 1.8 mm) and implants with the highest external hexagon height (1.8 mm) and different surface treatments (electropolishing, grit blasting with aluminium oxide, and acid etching with sulfuric acid) were tested to evaluate their mechanical fatigue life. To do so, 10-Hz triangular flexural load cycles were applied at 37 degrees C in artificial saliva, and the number of load cycles until implant fracture was determined. Tolerances of the hexagon/abutment fit and implant surface roughness were analyzed by scanning electron microscopy and light interferometry. Transmission electron microscopy and electron diffraction analyses of titanium hydrides were performed. First, the fatigue life of implants with the highest hexagon (8,683 +/- 978 load cycles) was more than double that of the implants with the shortest hexagons (3,654 +/- 789 load cycles) (P < .02). Second, the grit-blasted implants had the longest fatigue life of the tested materials (21,393 +/- 2,356 load cycles), which was significantly greater than that of the other surfaces (P < .001). The compressive surface residual stresses induced when blasting titanium are responsible for this superior mechanical response. Third, precipitation of titanium hydrides in grain boundaries of titanium caused by hydrogen adsorption from the acid solution deteriorates the fatigue life of acid-etched titanium dental implants. These implants had the shortest fatigue life (P < .05). The fatigue life of threaded root-form dental implants varies with the height of the external hexagon and/or the surface treatment of the implant. An external hexagon height of 1.8 mm and/or a blasting treatment appear to significantly increase fatigue life of dental implants.
Liu, Yanchun; Nelson, Tyler; Cromeens, Barrett; Rager, Terrence; Lannutti, John; Johnson, Jed; Besner, Gail E
2016-10-01
The ability to deliver sustained-release, biologically active growth factors through custom designed tissue engineering scaffolds at sites of tissue regeneration offers great therapeutic opportunity. Due to the short in vivo half-lives of most growth factors, it is challenging to deliver these proteins to sites of interest where they may be used before being degraded. The application of subcritical CO2 uses gas-phase CO2 at subcritical pressures ranging from 41 to 62 bar (595-913 PSI) which avoids foaming by reducing the amount of CO2 dissolved in the polymer and maintains completely reversible plasticization. In the current study, heparin-binding EGF-like growth factor (HB-EGF) was embedded into polyglycolic acid (PGA)/Poly-l-latic acid (PLLA) scaffolds via subcritical CO2 exposure for the production of tissue engineered intestine (TEI). PGA fiber morphology after subcritical CO2 exposure was examined by scanning electron microscopy (SEM) and the distribution of HB-EGF embedded in the scaffold fibers was detected by HB-EGF immunofluorescent staining. In vivo implantation of HB-EGF-embedded scaffolds confirmed significantly improved TEI structure as a result of local delivery of the trophic growth factor. These findings may be critical for the production of TEI in the treatment of patients with short bowel syndrome in the future. Copyright © 2016 Elsevier Ltd. All rights reserved.
Centeno, J A; Mullick, F G; Panos, R G; Miller, F W; Valenzuela-Espinoza, A
1999-07-01
Raman spectroscopy (the analysis of scattered photons after excitation with a monochromatic light source) provides a nondestructive method for identifying organic and inorganic materials on the basis of the molecule's characteristic spectrum of vibrational frequencies. Although the technique has been predominantly applied in sciences other than pathology, the recent advent of high-quality microscope optics coupled to optical Raman spectrometers (a variation known as a Raman microprobe) rendered this technique amenable to applications in human pathology. In the Raman microprobe, a laser beam is focused on a spot approximately 1 microm in diameter on the surface of the sample, e.g., tissue, and the scattered light is collected and analyzed. In this investigation, we used the Raman microprobe for the identification of foreign materials in breast implant capsular tissues. The characteristic silicone group frequencies associated with the silicon-oxygen stretch, the silicone-carbon stretch, the silicon-methyl and the methyl carbon-hydrogen stretch frequencies were used to identify polydimethylsiloxane and to define chemical differences among the various other implant-related inclusions. All of the inclusions were positively identified in a series of 44 capsules from silicone gel-filled implants: polydimethylsiloxane was found in 44 of 44 capsules surrounding silicone gel-filled implants; polyurethane was seen in 4 of 4 capsules around polyurethane foam-coated gel-filled implants; 4 of 4 capsules enveloping Dacron patch gel-filled implants revealed Dacron; and talc was identified in 8 of these 44 capsules. Raman microspectroscopy provides a rapid, accurate, and sensitive method for identifying inclusions associated with silicone and other implant materials in tissue.
Park, Byung Woo; Yang, Hee Seok; Baek, Se Hyun; Park, Kwideok; Han, Dong Keun; Lee, Tae Soo
2007-06-01
To determine the effects of acrylic acid (AA) grafting by argon plasma treatment and of immobilization of arginine-glycine-aspartic acid (RGD) peptides on fibrovascular ingrowth rate into high-density porous polyethylene (HPPE) anophthalmic orbital implants. Sixty rabbits were divided into three groups, with 20 rabbits in each group: (1) control group, rabbits implanted with unmodified HPPE; (2) PAA group, rabbits implanted with HPPE grafted with poly(AA) by argon plasma treatment; (3) RGD group, rabbits implanted with HPPE grafted with AA by argon plasma treatment and subsequently immobilized with RGD peptide. An HPPE spherical implant was put in the abdominal muscles of rabbit. After implantation for 4 weeks, the retrieved implants were sectioned and stained with hematoxylin and eosin (H&E). Blood vessels were counted using CD-31 immunostaining. Cross-sectional areas of fibrovascular ingrowth, blood vessel densities, and host inflammatory response scores were determined for all three groups. The mean cross-sectional areas of fibrovascularization at 2 and 3 weeks after implantation were the greatest in the RGD group, followed by the PAA group. While minimal fibrovascular ingrowths were noted in all implants at 1 week, all the implants showed nearly complete ingrowth at 4 weeks. Blood vessel densities were the highest in the RGD group, followed by the PAA group at 2, 3, and 4 weeks. The mean inflammation scores of the PAA and RGD groups were less than that of the control group. Fibrovascularization into HPPE implants was enhanced by surface grafting of AA and further improved by immobilizing RGD peptides onto the grafted AA surfaces. The inflammatory reactions were mild by either technique of surface modification.
Nguyen, Su Duy; Öörni, Katariina; Lee-Rueckert, Miriam; Pihlajamaa, Tero; Metso, Jari; Jauhiainen, Matti; Kovanen, Petri T.
2012-01-01
HDL particles may enter atherosclerotic lesions having an acidic intimal fluid. Therefore, we investigated whether acidic pH would affect their structural and functional properties. For this purpose, HDL2 and HDL3 subfractions were incubated for various periods of time at different pH values ranging from 5.5 to 7.5, after which their protein and lipid compositions, size, structure, and cholesterol efflux capacity were analyzed. Incubation of either subfraction at acidic pH induced unfolding of apolipoproteins, which was followed by release of lipid-poor apoA-I and ensuing fusion of the HDL particles. The acidic pH-modified HDL particles exhibited an enhanced ability to promote cholesterol efflux from cholesterol-laden primary human macrophages. Importantly, treatment of the acidic pH-modified HDL with the mast cell-derived protease chymase completely depleted the newly generated lipid-poor apoA-I, and prevented the acidic pH-dependent increase in cholesterol efflux. The above-found pH-dependent structural and functional changes were stronger in HDL3 than in HDL2. Spontaneous acidic pH-induced remodeling of mature spherical HDL particles increases HDL-induced cholesterol efflux from macrophage foam cells, and therefore may have atheroprotective effects. PMID:22855736
Miike, Tomohiro; Shirahase, Hiroaki; Jino, Hiroshi; Kunishiro, Kazuyoshi; Kanda, Mamoru; Kurahashi, Kazuyoshi
2008-01-02
THP-1 cell-derived foam cells were exposed to oxidative stress through combined treatment with acetylated LDL (acLDL) and copper ions (Cu2+). The foam cells showed caspase-dependent apoptotic changes on exposure to oxidative stress for 6 h, and necrotic changes with the leakage of LDH after 24 h. KY-455, an anti-oxidative ACAT inhibitor, and ascorbic acid (VC) but not YM-750, an ACAT inhibitor, prevented apoptotic and necrotic changes. These preventive effects of KY-455 and VC were accompanied by the inhibition of lipid peroxidation in culture medium containing acLDL and Cu2+, suggesting the involvement of oxidized acLDL in apoptosis and necrosis. Foam cells accumulated esterified cholesterol (EC) for 24 h in the presence of acLDL without Cu2+, which was suppressed by KY-455 and YM-750. Foam cells showed necrotic changes and died in the presence of acLDL and Cu2+. KY-455 but not YM-750 prevented cell death and reduced the amount of EC accumulated. The foam cells treated with VC further accumulated EC without necrotic changes for 24 h even in the presence of acLDL and Cu2+. YM-750 as well as KY-455 inhibited lipid accumulation when co-incubated with VC in foam cells exposed to oxidative stress. It is concluded that an anti-oxidative ACAT inhibitor or the combination of an antioxidant and an ACAT inhibitor protects foam cells from oxidative stress and effectively reduces cholesterol levels, which would be a promising approach in anti-atherosclerotic therapy.
NASA Technical Reports Server (NTRS)
Goldstein, A. S.; Juarez, T. M.; Helmke, C. D.; Gustin, M. C.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
2001-01-01
Culture of seeded osteoblastic cells in three-dimensional osteoconductive scaffolds in vitro is a promising approach to produce an osteoinductive material for repair of bone defects. However, culture of cells in scaffolds sufficiently large to bridge critical-sized defects is a challenge for tissue engineers. Diffusion may not be sufficient to supply nutrients into large scaffolds and consequently cells may grow preferentially at the periphery under static culture conditions. Three alternative culturing schemes that convect media were considered: a spinner flask, a rotary vessel, and a perfusion flow system. Poly(DL-lactic-co-glycolic acid) (PLGA) foam discs (12.7 mm diameter, 6.0 mm thick, 78.8% porous) were seeded with osteoblastic marrow stromal cells and cultured in the presence of dexamethasone and L-ascorbic acid for 7 and 14 days. Cell numbers per foam were found to be similar with all culturing schemes indicating that cell growth could not be enhanced by convection, but histological analysis indicated that the rotary vessel and flow system produced a more uniform distribution of cells throughout the foams. Alkaline phosphatase (ALP) activity per cell was higher with culture in the flow system and spinner flask after 7 days, while no differences in osteocalcin (OC) activity per cell were observed among culturing methods after 14 days in culture. Based on the higher ALP activity and better cell uniformity throughout the cultured foams, the flow system appears to be the superior culturing method, although equally important is the fact that in none of the tests did any of the alternative culturing techniques underperform the static controls. Thus, this study demonstrates that culturing techniques that utilize fluid flow, and in particular the flow perfusion system, improve the properties of the seeded cells over those maintained in static culture.
[Comperative study of implant surface characteristics].
Katona, Bernadett; Daróczi, Lajos; Jenei, Attila; Bakó, József; Hegedus, Csaba
2013-12-01
The osseointegration between the implant and its' bone environment is very important. The implants shall meet the following requirements: biocompatibility, rigidity, resistance against corrosion and technical producibility. In our present study surface morphology and material characteristics of different implants (Denti Bone Level, Denti Zirconium C, Bionika CorticaL, Straumann SLA, Straumann SLA Active, Dentsply Ankylos and Biotech Kontact implant) were investigated with scanning electron microscopy and energy-dispersive X-ray spectroscopy. The possible surface alterations caused by the manufacturing technology were also investigated. During grit-blasting the implants' surface is blasted with hard ceramic particles (titanium oxide, alumina, calcium phosphate). Properties of blasting material are critical because the osseointegration of dental implants should not be hampered. The physical and chemical features of blasting particles could importantly affect the produced surfaces of implants. Titanium surfaces with micro pits are created after immersion in mixtures of strong acids. On surfaces after dual acid-etching procedures the crosslinking between fibrin and osteogenetic cells could be enhanced therefore bone formation could be directly facilitated on the surface of the implant. Nowadays there are a number of surface modification techniques available. These can be used as a single method or in combination with each other. The effect of the two most commonly used surface modifications (acid-etching and grit-blasting) on different implants are demonstrated in our investigation.
Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions
Ross, Alexandra P; Webster, Thomas J
2013-01-01
Current titanium-based implants are often anodized in sulfuric acid (H2SO4) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone–implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications. PMID:23319862
Anodizing color coded anodized Ti6Al4V medical devices for increasing bone cell functions.
Ross, Alexandra P; Webster, Thomas J
2013-01-01
Current titanium-based implants are often anodized in sulfuric acid (H(2)SO(4)) for color coding purposes. However, a crucial parameter in selecting the material for an orthopedic implant is the degree to which it will integrate into the surrounding bone. Loosening at the bone-implant interface can cause catastrophic failure when motion occurs between the implant and the surrounding bone. Recently, a different anodization process using hydrofluoric acid has been shown to increase bone growth on commercially pure titanium and titanium alloys through the creation of nanotubes. The objective of this study was to compare, for the first time, the influence of anodizing a titanium alloy medical device in sulfuric acid for color coding purposes, as is done in the orthopedic implant industry, followed by anodizing the device in hydrofluoric acid to implement nanotubes. Specifically, Ti6Al4V model implant samples were anodized first with sulfuric acid to create color-coding features, and then with hydrofluoric acid to implement surface features to enhance osteoblast functions. The material surfaces were characterized by visual inspection, scanning electron microscopy, contact angle measurements, and energy dispersive spectroscopy. Human osteoblasts were seeded onto the samples for a series of time points and were measured for adhesion and proliferation. After 1 and 2 weeks, the levels of alkaline phosphatase activity and calcium deposition were measured to assess the long-term differentiation of osteoblasts into the calcium depositing cells. The results showed that anodizing in hydrofluoric acid after anodizing in sulfuric acid partially retains color coding and creates unique surface features to increase osteoblast adhesion, proliferation, alkaline phosphatase activity, and calcium deposition. In this manner, this study provides a viable method to anodize an already color coded, anodized titanium alloy to potentially increase bone growth for numerous implant applications.
Synthesis of rigid polyurethane foams from phosphorylated biopolyols.
de Haro, Juan Carlos; López-Pedrajas, Daniel; Pérez, Ángel; Rodríguez, Juan Francisco; Carmona, Manuel
2017-08-18
Renewable resources are playing a key role on the synthesis of biodegradable polyols. Moreover, the incorporation of covalently linked additives is increasing in importance in the polyurethane (PU) market. In this work, previously epoxidized grape seed oil and methyl oleate were transformed into phosphorylated biopolyols through an acid-catalyzed ring-opening hydrolysis in the presence of H 3 PO 4 . The formation of phosphate polyesters was confirmed by FT-IR and 31 P-NMR. However, the synthesis of a high-quality PU rigid foam was not possible using exclusively these polyols attending to their low hydroxyl value. In that way, different rigid PU foams were prepared from the phosphorylated biopolyols and the commercial polyol Alcupol R4520. It was observed that phosphorylated biopolyols can be incorporated up to a 57 wt.% in the PU synthesis without significant structural changes with respect to the commercial foam. Finally, thermogravimetric and EDAX analyses revealed an improvement of thermal stability by the formation of a protective phosphorocarbonaceous char layer.
Li, Yang; Ren, Hongfeng; Ragauskas, Arthur J
2011-08-01
Novel rigid polyurethane nanocomposite foams have been prepared by the polymerization of a sucrose-based polyol, a glycerol-based polyol and polymeric diphenylmethane diisocyanate in the presence of cellulose whiskers. Varying amounts of sulfuric acid hydrolyzed cellulose whiskers (0.25, 0.50, 0.75 and 1.00 wt%) prepared from a commercial fully bleached softwood kraft pulp were incorporated to investigate the effect of its dosage on the mechanical and thermal properties of polyurethane nanocomposites. Fourier transform infrared spectra of the nanocomposite foams suggested that additional hydrogen bonds were developed and crosslinking occurred between the hydroxyl groups of cellulose whiskers and isocyanate groups which increased the phase separation of soft and hard segments in the polyurethane. The closed cells of control foam and nanocomposite foams were homogeneously dispersed and the cell sizes were approximately 350 microm in diameter as observed by scanning electron microscope. A substantial improvement of mechanical properties at low whisker content (< or = 1.00 wt%) was obtained, especially the compressive strength and modulus at 1.00 wt% whiskers content which were increased by 269.7% and 210.0%, respectively. Thermal stability of the nanocomposites was also enhanced as determined by differential scanning calorimetry and thermogravimetric analysis.
Goldman, JM and Murr, AS. Dibromoacetic Acid-induced Elevations of Estradiol in Both Cycling and Ovariectomized / Estradiol-implanted Female Rats
ABSTRACT
Haloacetic acids are one of the principal classes of disinfection by-products generated by the chlorination of mun...
Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
NASA Technical Reports Server (NTRS)
Ishaug, S. L.; Crane, G. M.; Miller, M. J.; Yasko, A. W.; Yaszemski, M. J.; Mikos, A. G.; McIntire, L. V. (Principal Investigator)
1997-01-01
Bone formation was investigated in vitro by culturing stromal osteoblasts in three-dimensional (3-D), biodegradable poly(DL-lactic-co-glycolic acid) foams. Three polymer foam pore sizes, ranging from 150-300, 300-500, and 500-710 microns, and two different cell seeding densities, 6.83 x 10(5) cells/cm2 and 22.1 x 10(5) cells/cm2, were examined over a 56-day culture period. The polymer foams supported the proliferation of seeded osteoblasts as well as their differentiated function, as demonstrated by high alkaline phosphatase activity and deposition of a mineralized matrix by the cells. Cell number, alkaline phosphatase activity, and mineral deposition increased significantly over time for all the polymer foams. Osteoblast foam constructs created by seeding 6.83 x 10(5) cells/cm2 on foams with 300-500 microns pores resulted in a cell density of 4.63 x 10(5) cells/cm2 after 1 day in culture; they had alkaline phosphatase activities of 4.28 x 10(-7) and 2.91 x 10(-6) mumol/cell/min on Days 7 and 28, respectively; and they had a cell density that increased to 18.7 x 10(5) cells/cm2 by Day 56. For the same constructs, the mineralized matrix reached a maximum penetration depth of 240 microns from the top surface of the foam and a value of 0.083 mm for mineralized tissue volume per unit of cross sectional area. Seeding density was an important parameter for the constructs, but pore size over the range tested did not affect cell proliferation or function. This study suggests the feasibility of using poly(alpha-hydroxy ester) foams as scaffolding materials for the transplantation of autogenous osteoblasts to regenerate bone tissue.
Naganuma, Makoto; Aoyama, Nobuo; Suzuki, Yasuo; Nishino, Haruo; Kobayashi, Kiyonori; Hirai, Fumihito; Watanabe, Kenji; Hibi, Toshifumi
2016-07-01
Mucosal healing is an important therapeutic goal for ulcerative colitis. Once-daily administration of budesonide 2-mg foam is widely used for inducing clinical remission. No study has assessed the usefulness of twice-daily budesonide 2mg foam on mucosal healing in ulcerative colitis patients. We explored the efficacy for mucosal healing of once- or twice-daily budesonide foam in distal ulcerative colitis patients. This study was a multicentre, randomised, double-blind, placebo-controlled trial. In all, 165 patients with active, mild to moderate distal ulcerative colitis were randomised to three groups: once- or twice-daily budesonide 2mg/25ml foam, or placebo foam, for 6 weeks. Complete mucosal healing [endoscopic subscore = 0] and the safety profile were assessed at Week 6. Prespecified and post hoc analyses were used. The percentages of complete mucosal healing in the twice-daily budesonide foam group were 46.4% compared with 23.6% in the once-daily group [p = 0.0097], or 5.6% in the placebo group [p < 0.0001]. The percentages of clinical remission and the percentages of endoscopic subscore ≤ 1 in the twice-daily budesonide foam group were 48.2% and 76.8%, compared with 50.9% and 69.1% in the once-daily group [no difference], or 20.4% and 46.3% in the placebo group [p = 0.0029 and p = 0.0007], respectively. In the subgroup of patients with previous use of a 5-aminosalicylic acid suppository or enema, there was a greater percentage of complete mucosal healing in the twice-daily budesonide foam group [32.0%] compared with that in the once-daily [8.7%, p = 0.0774] or placebo groups [4.8%, p = 0.0763], though there was no significant difference. No serious adverse event occurred. A significantly greater percentage of patients receiving twice-daily administration of budesonide foam compared with once-daily administration/placebo achieved complete mucosal healing. This is the first study to evaluate the endoscopic efficacy of twice-daily administration of 6-week budesonide foam treatment for ulcerative colitis. © European Crohn’s and Colitis Organisation 2015.
Aoyama, Nobuo; Suzuki, Yasuo; Nishino, Haruo; Kobayashi, Kiyonori; Hirai, Fumihito; Watanabe, Kenji; Hibi, Toshifumi
2016-01-01
Background and Aims: Mucosal healing is an important therapeutic goal for ulcerative colitis. Once-daily administration of budesonide 2-mg foam is widely used for inducing clinical remission. No study has assessed the usefulness of twice-daily budesonide 2mg foam on mucosal healing in ulcerative colitis patients. We explored the efficacy for mucosal healing of once- or twice-daily budesonide foam in distal ulcerative colitis patients. Methods: This study was a multicentre, randomised, double-blind, placebo-controlled trial. In all, 165 patients with active, mild to moderate distal ulcerative colitis were randomised to three groups: once- or twice-daily budesonide 2mg/25ml foam, or placebo foam, for 6 weeks. Complete mucosal healing [endoscopic subscore = 0] and the safety profile were assessed at Week 6. Prespecified and post hoc analyses were used. Results: The percentages of complete mucosal healing in the twice-daily budesonide foam group were 46.4% compared with 23.6% in the once-daily group [p = 0.0097], or 5.6% in the placebo group [p < 0.0001]. The percentages of clinical remission and the percentages of endoscopic subscore ≤ 1 in the twice-daily budesonide foam group were 48.2% and 76.8%, compared with 50.9% and 69.1% in the once-daily group [no difference], or 20.4% and 46.3% in the placebo group [p = 0.0029 and p = 0.0007], respectively. In the subgroup of patients with previous use of a 5-aminosalicylic acid suppository or enema, there was a greater percentage of complete mucosal healing in the twice-daily budesonide foam group [32.0%] compared with that in the once-daily [8.7%, p = 0.0774] or placebo groups [4.8%, p = 0.0763], though there was no significant difference. No serious adverse event occurred. Conclusions: A significantly greater percentage of patients receiving twice-daily administration of budesonide foam compared with once-daily administration/placebo achieved complete mucosal healing. This is the first study to evaluate the endoscopic efficacy of twice-daily administration of 6-week budesonide foam treatment for ulcerative colitis. PMID:26577683
The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants.
Frame, James; Kamel, Dia; Olivan, Marcelo; Cintra, Henrique
2015-10-01
Polyurethane breast implants were first introduced by Ashley (Plast Reconstr Surg 45:421-424, 1970), with the intention of trying to reduce the high incidence of capsular contracture associated with smooth shelled, high gel bleed, silicone breast implants. The sterilization of the polyurethane foam in the early days was questionable. More recently, ethylene oxide (ETO)-sterilized polyurethane has been used in the manufacturing process and this has been shown to reduce the incidence of biofilm. The improved method of attachment of polyurethane onto the underlying high cohesive gel, barrier shell layered, silicone breast implants also encourages bio-integration. Polyurethane covered, cohesive gel, silicone implants have also been shown to reduce the incidence of other problems commonly associated with smooth or textured silicone implants, especially with reference to displacement, capsular contracture, seroma, reoperation, biofilm and implant rupture. Since the introduction of the conical polyurethane implant (Silimed, Brazil) into the United Kingdom in 2009 (Eurosurgical, UK), we have had the opportunity to review histology taken from the capsules of polyurethane implants in three women ranging from a few months to over 3 years after implantation. All implants had been inserted into virgin subfascial, extra-pectoral planes. The results add to the important previously described histological findings of Bassetto et al. (Aesthet Plast Surg 34:481-485, 2010). Five distinct layers are identified and reasons for the development of each layer are discussed. Breast capsule around polyurethane implants, in situ for fifteen and 20 years, has recently been obtained and analysed in Brazil, and the histology has been incorporated into this study. After 20 years, the polyurethane is almost undetectable and capsular contracture may appear. These findings contribute to our understanding of polyurethane implant safety, and give reasoning for a significant reduction in clinical capsular contracture rate, up to 10 years after implantation, compared to contemporary silicone implants. A more permanent matrix equivalent to polyurethane may be the solution for reducing long-term capsular contracture. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Li, Yongshen; Song, Yunna; Li, Jihui; Li, Yuehai; Li, Ning; Niu, Shuai
2018-04-01
In this article, polyvinyl alcohol/phytic acid polymer (PVA/PA polymer) is synthesized from PVA and PA via the esterification reaction of PVA and PA in the case of acidity and ultrasound irradiation, and PVA/PA polymer sponge is prepared via foaming PVA/PA polymer in the presence of n-pentane and ammonium bicarbonate, and the structure of PVA/PA polymer and the structure, morphology and crystallinity of PVA/PA polymer sponge are characterized, and the thermal stability and surface resistivity of PVA/PA polymer sponge are investigated. Based on these, it has been attested that PVA/PA polymer synthesized under the acidity and ultrasound irradiation and PVA/PA polymer sponge are structured by the chain of PVA and the cricoid PA connected in the form of ether bonds and phosphonate bonds, and the thermal stability of PVA/PA polymer sponge attains 416.5 °C, and the surface resistivity of PVA/PA polymer sponge reaches 5.76 × 10 4 ohms/sq. Copyright © 2017 Elsevier B.V. All rights reserved.
Genotoxicity of corrosion eluates obtained from endosseous implants.
Ribeiro, Daniel Araki; Matsumoto, Mariza Akemi; Padovan, Luís Eduardo Marques; Marques, Mariângela Esther Alencar; Salvadori, Daisy Maria Fávero
2007-03-01
Commercially pure titanium alloys are currently used as metallic biomaterials in implantology. Corrosion phenomena appear to play a decisive role in metallic implant long-term behavior. Thus, the goal of this study was to examine the genotoxic potential of corrosion eluates obtained from dental implants using Chinese ovary hamster cells in vitro by the single-cell gel (comet) assay. This technique detects deoxyribonucleic acid strand breaks in individual cells in alkaline conditions. The materials tested included 3 dental implants commercially available. Each of the tested materials was corroded in a solution consisting of equal amounts of acetic acid and sodium chloride (0.1 M) for 1, 3, 7, 14, and 21 days. The Chinese ovary hamster cultures were then exposed to all corrosion eluates obtained from endosseous dental implants for 30 minutes at 37 degrees C. None of the eluates was found to exhibit genotoxicity, regardless of the type of dental implant used. The results suggest that all dental implants tested in this study did not induce deoxyribonucleic acid breakage as depicted by the single-cell gel (comet) assay.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lei, K.S.; Chang, F.; Levy, M.
1993-07-01
Pitting corrosion of molybdenum-ion-implanted, depleted uranium -0 75 Ti (DU -0 75 Ti) has been studied electrochemically in acidic, neutral, and alkaline solutions containing sodium chloride, and the results have been compared to those of the unimplanted DU -0 75 Ti. The data show that Mo implantation shifts the pitting potential of DU -0 75 Ti in the noble direction in acidic and alkaline solutions. In neutral 50 ppm Cl- solution, however, there is no beneficial effect of Mo implantation. Auger analysis studies show that before exposure to the solutions, all the molybdenum is in the oxide, which is approximatelymore » l000 A thick. After electrochemical scans in the acidic and alkaline chloride solutions, most of the Mo disappears from the oxide. However, no decrease in Mo concentration is found after exposure in neutral chloride solution. It is proposed that the implanted molybdenum dissolves in the acidic and alkaline solutions and forms simple or complex molybdates that inhibit pitting corrosion. The implanted molybdenum does not dissolve in the neutral chloride solution and inhibition does not occur.« less
Thompson, D E; Agrawal, C M; Athanasiou, K
1996-01-01
Biodegradable implants that release growth factors or other bioactive agents in a controlled manner are investigated to enhance the repair of musculoskeletal tissues. In this study, the in vitro release characteristics and mechanical properties of a 50:50 polylactic acid/polyglycolic acid two phase implant were examined over a 6-week period under no-load conditions or under a cyclic compressive load, such as that experienced when walking slowly during rehabilitation. The results demonstrated that a cyclic compressive load significantly slows the decrease of molecular chain size during the first week, significantly increases protein release for the first 2-3 weeks, and significantly stiffens the implant for the first 3 weeks. It was also shown that protein release is initially high and steadily decreases with time until the molecular weight declines to about 20% of its original value (approximately 4 weeks). Once this threshold is reached, increased protein release, surface deformation, and mass loss occurs. This study also showed that dynamic loading and the environment in which an implant is placed affect its biodegradation. Therefore, it may be essential that in vitro degradation studies of these or similar implants include a dynamic functional environment.
Influence of silica nanospheres on corrosion behavior of magnesium matrix syntactic foam
NASA Astrophysics Data System (ADS)
Qureshi, W.; Kannan, S.; Vincent, S.; Eddine, N. N.; Muhammed, A.; Gupta, M.; Karthikeyan, R.; Badari, V.
2018-04-01
Over the years, the development of Magnesium alloys as biodegradable implants has seen significant advancements. Magnesium based materials tend to provide numerous advantages in the field of biomedical implants over existing materials such as titanium or stainless steel. The present research focuses on corrosive behavior of Magnesium reinforced with different volume percentages of Hollow Silica Nano Spheres (HSNS). These behaviors were tested in two different simulated body fluids (SBF) namely, Hank’s Buffered Saline Solution (HBSS) and Phosphate Buffered Solution (PBS). This corrosion study was done using the method of electrochemical polarization with a three-electrode configuration. Comparative studies were established by testing pure Mg which provided critical information on the effects of the reinforcing material. The HSNS reinforced Mg displayed desirable characteristics after corrosion experiments; increased corrosion resistance was witnessed with higher volume percentage of HSNS.
Continuous microcellular foaming of polylactic acid/natural fiber composites
NASA Astrophysics Data System (ADS)
Diaz-Acosta, Carlos A.
Poly(lactic acid) (PLA), a biodegradable thermoplastic derived from renewable resources, stands out as a substitute to petroleum-based plastics. In spite of its excellent properties, commercial applications are limited because PLA is more expensive and more brittle than traditional petroleum-based resins. PLA can be blended with cellulosic fibers to reduce material cost. However, the lowered cost comes at the expense of flexibility and impact strength, which can be enhanced through the production of microcellular structures in the composite. Microcellular foaming uses inert gases (e.g., carbon dioxide) as physical blowing agents to make cellular structures with bubble sizes of less than 10 microm and cell-population densities (number of bubbles per unit volume) greater than 109 cells/cm³. These unique characteristics result in a significant increase in toughness and elongation at break (ductility) compared with unfoamed parts because the presence of small bubbles can blunt the crack-tips increasing the energy needed to propagate the crack. Microcellular foams have been produced through a two step batch process. First, large amounts of gas are dissolved in the solid plastic under high pressure (sorption process) to form a single-phase solution. Second, a thermodynamic instability (sudden drop in solubility) triggers cell nucleation and growth as the gas diffuses out of the plastic. Batch production of microcellular PLA has addressed some of the drawbacks of PLA. Unfortunately, the batch foaming process is not likely to be implemented in the industrial production of foams because it is not cost-effective. This study investigated the continuous microcellular foaming process of PLA and PLA/wood-fiber composites. The effects of the processing temperature and material compositions on the melt viscosity, pressure drop rate, and cell-population density were examined in order to understand the nucleation mechanisms in neat and filled PLA foams. The results indicated that the processing temperature had a strong effect of the rheology of the melt and cell morphology. Processing at a lower temperature significantly increased the cell nucleation rate of neat PLA (amorphous and semi-crystalline) because of the fact that a high melt viscosity induced a high pressure drop rate in the polymer/gas solution. The presence of nanoclay did not affect the homogeneous nucleation but increased the heterogeneous nucleation, allowing both nucleation mechanisms to occur during the foaming process. The effect of wood-flour (0-30 wt.%) and rheology modifier contents on the melt viscosity and cell morphology of microcellular foamed composites was investigated. The viscosity of the melt increased with wood-flour content and decreased with rheology modifier content, affecting the processing conditions (i.e., pressure drop and pressure drop rate) and foamability of the composites. Matching the viscosity of the composites with that of neat PLA resulted in the best cell morphologies. Physico-mechanical characterization of microcellular foamed PLA as a function of cell morphology was performed to establish process-morphology-property relationships. The processing variables, i.e., amount of gas injected, flow rate, and processing temperature affected the development of the cellular structure and mechanical properties of the foams.
Tian, Fang; Yao, Jianting; Yan, Meng; Sun, Xin; Wang, Wei; Gao, Weiwei; Tian, Zhen; Guo, Shuyuan; Dong, Zengxiang; Li, Bicheng; Gao, Tielei; Shan, Peng; Liu, Bing; Wang, Haiyang; Cheng, Jiali; Gao, Qianping; Zhang, Zhiguo; Cao, Wenwu; Tian, Ye
2016-01-01
Necroptosis, or programmed necrosis, contributes to the formation of necrotic cores in atherosclerotic plaque in animal models. However, whether inhibition of necroptosis ameliorates atherosclerosis is largely unknown. In this study, we demonstrated that necroptosis occurred in clinical atherosclerotic samples, suggesting that it may also play an important role in human atherosclerosis. We established an in vitro necroptotic model in which necroptosis was induced in THP-1-derived foam cells by serum deprivation. With this model, we demonstrated that 5-aminolevulinic acid-mediated sonodynamic therapy (ALA-SDT) inhibited necroptosis while promoting apoptosis. ALA-SDT activated the caspase-3 and caspase-8 pathways in foam cells, which is responsible for the switch from necroptosis to apoptosis. The inhibition of either caspase-8 or caspase-3 abolished the anti-necroptotic effect of ALA-SDT. In addition, we found that caspase-3 activation peaked 4 hours after ALA-SDT treatment, 2 hours earlier than maximal caspase-8activation. Taken together, our data indicate that ALA-SDT mediates the switch from necroptosis to apoptosis by activating the caspase-3 and caspase-8 pathways and may improve the prognosis of atherosclerosis. PMID:26911899
Hosseini-Nasab, S M; Zitha, P L J
2017-01-01
The objective of this study is to discover a synergistic effect between foam stability in bulk and micro-emulsion phase behaviour to design a high-performance chemical system for an optimized alkaline-surfactant-foam (ASF) flooding for enhanced oil recovery (EOR). The focus is on the interaction of ASF chemical agents with oil in the presence and absence of a naphthenic acid component and in situ soap generation under bulk conditions. To do so, the impact of alkalinity, salinity, interfacial tension (IFT) reduction and in situ soap generation was systematically studied by a comprehensive measurement of (1) micro-emulsion phase behaviour using a glass tube test method, (2) interfacial tension and (3) foam stability analysis. The presented alkali-surfactant (AS) formulation in this study lowered IFT between the oil and aqueous phases from nearly 30 to 10 -1 -10 -3 mN/m. This allows the chemical formulation to create considerably low IFT foam flooding with a higher capillary number than conventional foam for displacing trapped oil from porous media. Bulk foam stability tests demonstrated that the stability of foam diminishes in the presence of oil with large volumes of in situ soap generation. At lower surface tensions (i.e. larger in situ soap generation), the capillary suction at the plateau border is smaller, thus uneven thinning and instabilities of the film might happen, which will cause acceleration of film drainage and lamellae rupture. This observation could also be interpreted by the rapid spreading of oil droplets that have a low surface tension over the lamella. The spreading oil, by augmenting the curvature radius of the bubbles, decreases the surface elasticity and surface viscosity. Furthermore, the results obtained for foam stability in presence of oil were interpreted in terms of phenomenological theories of entering/spreading/bridging coefficients and lamella number.
Preparation of graphene foam with high performance by modified self-assembly method
NASA Astrophysics Data System (ADS)
Zhang, Wenhui; Sun, Youyi; Liu, Tantan; Li, Diansen; Hou, Chunlin; Gao, Li; Liu, Yaqing
2016-03-01
Recently, self-assembly method was applied for preparation of graphene foam. However, it is still a great challenge to obtain a three-dimensional graphene network with high performance (e.g., low density, high mechanical strength and high conductivity together) for the self-assembly method. Herein, a modified self-assembly method applied for preparation of graphene foam was investigated, in which, L-ascorbic acid and HI were firstly chosen as the reducing agent, and further reduced by hydrazine hydrate. The results demonstrated that the graphene foam showed high compressive strength (ca. 320 kPa), high electrical conductivity (20.6 S/m) and low density (14.7 mg/cm-1). Especially, the obtained compressive strength (ca. 320 kPa) is the highest value compared to the data of graphene foam reported in previous works. This phenomenon may be due to following three reasons: (1) the reaction between hydrazine hydrate and graphene brought some covalent bonds among graphene sheets; (2) graphene foam was achieved by high hydrophobicity and electrostatic repulsion which inhibit the restacking of graphene sheets; (3) the removal of the oxygen groups by hydrazine hydrate efficiently restores conjugation of sp2 regions and the π-π interaction in the cross-linking sites, which tightly bonds the sheets together. The obtained graphene foam not only had good porous structure and mechanical strength, but also showed excellent satisfactory double-layer capacitive behavior with good electrochemical cyclic stability and high specific capacitance of 171.0 F/g for application in electrode of supercapacitors and absorption capacities for the removal of various oils and dyes from water.
Dauchy, Xavier; Boiteux, Virginie; Bach, Cristina; Rosin, Christophe; Munoz, Jean-François
2017-09-01
To extinguish large-scale fuel fires, fluorosurfactant based foams (FSBFs) were developed in the 1960s and have been used ever since. In this study, 154 per- and polyfluoroalkyl substances (PFASs) including 122 emerging PFASs used as surfactants in FSBFs were sought in nine different foam concentrates. Field investigations were also carried out in the vicinity of four sites where FSBFs are or were intensively used (two airports, a training center for firefighters and an oil storage depot after a large explosion). In the foam concentrates, only three PFASs were quantified with concentrations ranging from 22,500 to 3,188,000 μg/L. Thirteen emerging PFASs were also identified in these samples based on their mass transitions and intensities. Overall, each foam was a mixture of at least two classes of PFASs. In three concentrates, none of the 122 emerging PFASs were identified as the main ingredient. A perfluoroalkyl acid precursor oxidation assay was therefore performed, and revealed the presence of high amounts of unidentified PFASs. In the vicinity of the four investigated sites, several PFASs were systematically quantified in all of the samples collected downstream of the sites. PFAS profiles were heavily influenced by parameters such as route of PFAS transport after use (runoff, seepage, direct discharge), time elapsed since the cessation of firefighting activities, and firefighting foam composition. The PFAS concentrations found around the investigated sites are the highest recorded in France and resulted in the closure of certain drinking water resources. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ao, Haiyong; Zong, Jiajia; Nie, Yanjiao; Wan, Yizao; Zheng, Xiebin
2018-03-01
Aseptic loosening of implant is one of the main causes of Ti-based implant failure. In our previous work, a novel stable collagen/hyaluronic acid (Col/HA) multilayer modified titanium coatings (TCs) was developed by layer-by-layer (LBL) covalent immobilization technique, which showed enhanced biological properties compared with TCs that were physically absorbed with Col/HA multilayer in vitro . In this study, a rabbit model with femur condyle defect was employed to compare the osteointegration performance of them. Results indicated that Col/HA multilayer with favourable stability could better facilitate osteogenesis around implants and bone-implant contact. The Col/HA multilayer covalent-immobilized TC may reduce aseptic loosening of implant.
Cell Adhesion and in Vivo Osseointegration of Sandblasted/Acid Etched/Anodized Dental Implants
Kim, Mu-Hyon; Park, Kyeongsoon; Choi, Kyung-Hee; Kim, Soo-Hong; Kim, Se Eun; Jeong, Chang-Mo; Huh, Jung-Bo
2015-01-01
The authors describe a new type of titanium (Ti) implant as a Modi-anodized (ANO) Ti implant, the surface of which was treated by sandblasting, acid etching (SLA), and anodized techniques. The aim of the present study was to evaluate the adhesion of MG-63 cells to Modi-ANO surface treated Ti in vitro and to investigate its osseointegration characteristics in vivo. Four different types of Ti implants were examined, that is, machined Ti (control), SLA, anodized, and Modi-ANO Ti. In the cell adhesion study, Modi-ANO Ti showed higher initial MG-63 cell adhesion and induced greater filopodia growth than other groups. In vivo study in a beagle model revealed the bone-to-implant contact (BIC) of Modi-ANO Ti (74.20% ± 10.89%) was much greater than those of machined (33.58% ± 8.63%), SLA (58.47% ± 12.89), or ANO Ti (59.62% ± 18.30%). In conclusion, this study demonstrates that Modi-ANO Ti implants produced by sandblasting, acid etching, and anodizing improve cell adhesion and bone ongrowth as compared with machined, SLA, or ANO Ti implants. These findings suggest that the application of Modi-ANO surface treatment could improve the osseointegration of dental implant. PMID:25955650
Wang, Tong-Mei; Lee, Ming-Shu; Wang, Juo-Song; Lin, Li-Deh
2015-01-01
This study investigated the effect of implant design and bone quality on insertion torque (IT), implant stability quotient (ISQ), and insertion energy (IE) by monitoring the continuous change in IT and ISQ while implants were inserted in artificial bone blocks that simulate bone of poor or poor-to-medium quality. Polyurethane foam blocks (Sawbones) of 0.16 g/cm³ and 0.32 g/cm³ were respectively used to simulate low density and low- to medium-density cancellous bone. In addition, some test blocks were laminated with a 1-mm 0.80 g/cm³ polyurethane layer to simulate cancellous bone with a thin cortical layer. Four different implants (Nobel Biocare Mk III-3.75, Mk III-4.0, Mk IV-4.0, and NobelActive-4.3) were placed into the different test blocks in accordance with the manufacturer's instructions. The IT and ISQ were recorded at every 0.5-mm of inserted length during implant insertion, and IE was calculated from the torque curve. The peak IT (PIT), final IT (FIT), IE, and final ISQ values were statistically analyzed. All implants showed increasing ISQ values when the implant was inserted more deeply. In contrast to the ISQ, implants with different designs showed dissimilar IT curve patterns during the insertion. All implants showed a significant increase in the PIT, FIT, IE, and ISQ when the test-block density increased or when the 1-mm laminated layer was present. Tapered implants showed FIT or PIT values of more than 40 Ncm for all of the laminated test blocks and for the nonlaminated test blocks of low to medium density. Parallel-wall implants did not exhibit PIT or FIT values of more than 40 Ncm for all of the test blocks. NobelActive-4.3 showed a significantly higher FIT, but a significantly lower IE, than Mk IV-4.0. While the existence of cortical bone or implant designs significantly affects the dynamic IT profiles during implant insertion, it does not affect the ISQ to a similar extent. Certain implant designs are more suitable than others if high IT is required in bone of poor quality. The manner in which IT, IE, and ISQ represent the implant primary stability requires further study.
NASA Astrophysics Data System (ADS)
Yang, Yingge; Fan, Yonghong; Li, Wen; Wang, Dongmei; Wu, Yuejin; Zheng, Zhiming; Yu, Zengliang
2007-10-01
In order to obtain an industrial strain with a higher L(+)-lactic acid yield, the strain Rhizopus oryzae PW352 was mutated by means of nitrogen ion beam implantation and the mutant strain Rhizopus oryzae RLC41-6 was obtained. An experimental finding was made in surprise that Rhizopus oryzae mutant RLC41-6 is not only an L(+)-lactic acid producer from corn starch but also an efficient producer of L(+)-lactic acid from xylose. Under optimal conditions, the production of L(+)-lactic acid from 100 g/L xylose reached 77.39 g/L after 144 h fed-batch fermentation. A high mutation rate and a wide mutation spectrum of low-energy ion implantation were observed in the experiment.
Rouholamin, Davood; van Grunsven, William; Reilly, Gwendolen C; Smith, Patrick J
2016-08-01
A novel supercritical CO2 foaming technique was used to fabricate scaffolds of controllable morphology and mechanical properties, with the potential to tailor the scaffolds to specific tissue engineering applications. Biodegradable scaffolds are widely used as temporary supportive structures for bone regeneration. The scaffolds must provide a sufficient mechanical support while allowing cell attachment and growth as well as metabolic activities. In this study, supercritical CO2 foaming was used to prepare fully interconnected porous scaffolds of poly-d,l-lactic acid and poly-d,l-lactic acid/hydroxyapatite. The morphological, mechanical and cell behaviours of the scaffolds were measured to examine the effect of hydroxyapatite on these properties. These scaffolds showed an average porosity in the range of 86%-95%, an average pore diameter of 229-347 µm and an average pore interconnection of 103-207 µm. The measured porosity, pore diameter, and interconnection size are suitable for cancellous bone regeneration. Compressive strength and modulus of up to 36.03 ± 5.90 and 37.97 ± 6.84 MPa were measured for the produced porous scaffolds of various compositions. The mechanical properties presented an improvement with the addition of hydroxyapatite to the structure. The relationship between morphological and mechanical properties was investigated. The matrices with different compositions were seeded with bone cells, and all the matrices showed a high cell viability and biocompatibility. The number of cells attached on the matrices slightly increased with the addition of hydroxyapatite indicating that hydroxyapatite improves the biocompatibility and proliferation of the scaffolds. The produced poly-d,l-lactic acid/hydroxyapatite scaffolds in this study showed a potential to be used as bone graft substitutes. © IMechE 2016.
Formulation and acceptability of foam mat dried seabuckthorn (Hippophae salicifolia) leather.
Kaushal, Manisha; Sharma, P C; Sharma, Rakesh
2013-02-01
Technology for utilization of seabuckthorn berries for preparation of fruit leather/bar was optimized by modifying the foam mat drying technique. The conversion of seabuckthorn juice/pulp into foam was standardized by whipping the pulp after addition of CMC @ 0-3% at 5 °C and drying the resultant foam in dehydrator (55 ± 2 °C) to a moisture content of about 12-14%. The fruit bar prepared from sulphited juice/pulp wrapped in a butter paper followed by packing in polyethylene pouches (20 g) and stored at ambient temperature (14.6-26.1 °C) experienced least changes in quality attributes like ascorbic acid (1045.7 mg/100 g vs 997.5 mg/100 g) and carotenoids (80.4 mg/100 g vs 72.3 mg/100 g) as compared to the leather made from the unsulphited pulp. Storage studies indicate that fruit bars are mildly hygroscopic (0.46-0.65) and can be stored within the RH of 46-65% at room temperature.
Lee, Chang-Gu; Song, Mi-Kyung; Ryu, Jae-Chun; Park, Chanhyuk; Choi, Jae-Woo; Lee, Sang-Hyup
2016-06-01
Electroplating wastewater contains various types of toxic substances, such as heavy metals, solvents, and cleaning agents. Carbon foam was used as an adsorbent for the removal of heavy metals from real industrial plating wastewater. Its sorption capacity was compared with those of a commercial ion-exchange resin (BC258) and a heavy metal adsorbent (CupriSorb™) in a batch system. The experimental carbon foam has a considerably higher sorption capacity for Cr and Cu than commercial adsorbents for acid/alkali wastewater and cyanide wastewater. Additionally, cytotoxicity test showed that the newly developed adsorbent has low cytotoxic effects on three kinds of human cells. In a pilot plant, the carbon foam had higher sorption capacity for Cr (73.64 g kg(-1)) than for Cu (14.86 g kg(-1)) and Ni (7.74 g kg(-1)) during 350 h of operation time. Oxidation pretreatments using UV/hydrogen peroxide enhance heavy metal removal from plating wastewater containing cyanide compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.
Xiao, J; Zhou, H; Zhao, L; Sun, Y; Guan, S; Liu, B; Kong, L
2011-06-01
Hydrofluoric etching and anodized hierarchical micro/nanotextured surface titanium implant was placed in mandibles of ovariectomized sheep for 12 weeks, and it showed improved osseointegration by resonance frequency analysis (RFA), microcomputed tomography (micro-CT) evaluation, histomorphometry, and biomechanical test. This study aimed to investigate the effects of micro/nanotextured titanium implant on osseointegration in ovariectomized (OVX) sheep. The hierarchical micro/nanotextured surface of titanium implant was fabricated by acid in 0.5% (w/v) hydrofluoric (HF) and anodized in HF acid electrolytes with a DC power of 20 V, and the machined surface implants with no treatment served as control group. The implants were placed in mandibles of OVX sheep, respectively. Twelve weeks after implantation, RFA, microcomputed tomography, histomorphometry, and biomechanical tests were applied to detect the osseointegration of the two groups. The implant stability quotient (ISQ) values, the maximum pull-out forces, and the bone-implant contact (BIC) were 65.5 ± 6.3, 490.6 ± 72.7 N, and 58.31 ± 5.79% in the micro/nanogroup and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85 ± 5.04% in the control group, respectively. There was no significant difference between the two groups in ISQ values (p > 0.05), but in the micro/nanogroup, the maximal pull-out force and the BIC were increased significantly (p < 0.05 or p < 0.01). Micro-CT analysis showed that the bone volume ratio and the trabecular number increased significantly (p < 0.01), and the trabecular separation decreased significantly (p < 0.05) in the micro/nanogroup. Implant modification by HF acid etching and anodization to form a hierarchical micro/nanotextured surface could improve titanium implant osseointegration in OVX sheep 12 weeks after implantation.
Espinar-Escalona, Eduardo; Bravo-Gonzalez, Luis-Alberto; Pegueroles, Marta; Gil, Francisco Javier
2016-06-01
Self-drilling orthodontic mini-implants can be used as temporary devices for orthodontic treatments. Our main goal was to evaluate surface characteristics, roughness and wettability, of surface modified mini-implants to increase their stability during orthodontic treatment without inducing bone fracture and tissue destruction during unscrewing. Modified mini-implants by acid etching, grit-blasting and its combination were implanted in 20 New Zealand rabbits during 10 weeks. After that, the bone-to-implant (BIC) parameter was determined and the torque during unscrewing was measured. The surface characteristics, roughness and wettability, were also measured, onto modified Ti c.p. discs. Acid-etched mini-implants (R a ≈ 1.7 μm, contact angle (CA) ≈ 66°) significantly improved the bone-to-implant parameter, 26 %, compared to as-machined mini-implants (R a ≈ 0.3 μm, CA ≈ 68°, BIC = 19 %) due to its roughness. Moreover, this surface treatment did not modify torque during unscrewing due to their statistically similar wettability (p > 0.05). Surface treatments with higher roughness and hydrophobicity (R a ≈ 4.5 μm, CA ≈ 74°) lead to a greater BIC and to a higher removal torque during unscrewing, causing bone fracture, compared to as-machined mini-implants. Based on these in vivo findings, we conclude that acid-etching surface treatment can support temporary anchoring of titanium mini-implants. This treatment represents a step forward in the direction of reducing the time prior to mini-implant loading by increasing their stability during orthodontic treatment, without inducing bone fracture and tissue destruction during unscrewing.
Kelly, Nicola; McGarry, J Patrick
2012-05-01
The inelastic pressure dependent compressive behaviour of bovine trabecular bone is investigated through experimental and computational analysis. Two loading configurations are implemented, uniaxial and confined compression, providing two distinct loading paths in the von Mises-pressure stress plane. Experimental results reveal distinctive yielding followed by a constant nominal stress plateau for both uniaxial and confined compression. Computational simulation of the experimental tests using the Drucker-Prager and Mohr-Coulomb plasticity models fails to capture the confined compression behaviour of trabecular bone. The high pressure developed during confined compression does not result in plastic deformation using these formulations, and a near elastic response is computed. In contrast, the crushable foam plasticity models provide accurate simulation of the confined compression tests, with distinctive yield and plateau behaviour being predicted. The elliptical yield surfaces of the crushable foam formulations in the von Mises-pressure stress plane accurately characterise the plastic behaviour of trabecular bone. Results reveal that the hydrostatic yield stress is equal to the uniaxial yield stress for trabecular bone, demonstrating the importance of accurate characterisation and simulation of the pressure dependent plasticity. It is also demonstrated in this study that a commercially available trabecular bone analogue material, cellular rigid polyurethane foam, exhibits similar pressure dependent yield behaviour, despite having a lower stiffness and strength than trabecular bone. This study provides a novel insight into the pressure dependent yield behaviour of trabecular bone, demonstrating the inadequacy of uniaxial testing alone. For the first time, crushable foam plasticity formulations are implemented for trabecular bone. The enhanced understanding of the inelastic behaviour of trabecular bone established in this study will allow for more realistic simulation of orthopaedic device implantation and failure. Copyright © 2011 Elsevier Ltd. All rights reserved.
Sandborn, William J.; Rubin, David T.; Harper, Joseph R.
2016-01-01
Background: Rectal budesonide foam is a second-generation corticosteroid efficacious for active mild to moderate ulcerative proctitis and ulcerative proctosigmoiditis. This subgroup analysis examined the impact of baseline oral 5-aminosalicylic acid (5-ASA) on the efficacy and safety of budesonide foam in patients with mild to moderate ulcerative proctitis or ulcerative proctosigmoiditis. Methods: Patients received budesonide foam 2 mg/25 mL twice daily for 2 weeks, then once daily for 4 weeks, or placebo, with or without continued stable dosing of baseline oral 5-ASAs, for remission induction at week 6 (primary endpoint) in 2 identically designed, randomized, double-blind, phase 3 studies. Results: Of the 267 and 279 patients randomized to treatment with budesonide foam or placebo (pooled population), 55.1% and 55.2%, respectively, reported baseline 5-ASA use. A significantly greater percentage of patients achieved remission with budesonide foam versus placebo, either with (42.2% versus 31.8%, respectively; P = 0.03) or without (40.0% versus 14.4%; P < 0.0001) baseline 5-ASA use at week 6. A significantly greater percentage of patients achieved a Modified Mayo Disease Activity Index rectal bleeding subscale score of 0 at week 6, regardless of baseline 5-ASA use (5-ASA, 50.3% versus 35.7%; P = 0.003: no 5-ASA, 45.8% versus 19.2%; P < 0.0001). The frequency of adverse events was comparable between groups, regardless of baseline 5-ASA use. Conclusions: Budesonide foam was efficacious and safe for induction of remission of mild to moderate ulcerative proctitis and ulcerative proctosigmoiditis in patients receiving oral 5-ASA at baseline and those who were not (Clinicaltrials.gov: NCT01008410 and NCT01008423). PMID:27416045
Bosworth, Brian P; Sandborn, William J; Rubin, David T; Harper, Joseph R
2016-08-01
Rectal budesonide foam is a second-generation corticosteroid efficacious for active mild to moderate ulcerative proctitis and ulcerative proctosigmoiditis. This subgroup analysis examined the impact of baseline oral 5-aminosalicylic acid (5-ASA) on the efficacy and safety of budesonide foam in patients with mild to moderate ulcerative proctitis or ulcerative proctosigmoiditis. Patients received budesonide foam 2 mg/25 mL twice daily for 2 weeks, then once daily for 4 weeks, or placebo, with or without continued stable dosing of baseline oral 5-ASAs, for remission induction at week 6 (primary endpoint) in 2 identically designed, randomized, double-blind, phase 3 studies. Of the 267 and 279 patients randomized to treatment with budesonide foam or placebo (pooled population), 55.1% and 55.2%, respectively, reported baseline 5-ASA use. A significantly greater percentage of patients achieved remission with budesonide foam versus placebo, either with (42.2% versus 31.8%, respectively; P = 0.03) or without (40.0% versus 14.4%; P < 0.0001) baseline 5-ASA use at week 6. A significantly greater percentage of patients achieved a Modified Mayo Disease Activity Index rectal bleeding subscale score of 0 at week 6, regardless of baseline 5-ASA use (5-ASA, 50.3% versus 35.7%; P = 0.003: no 5-ASA, 45.8% versus 19.2%; P < 0.0001). The frequency of adverse events was comparable between groups, regardless of baseline 5-ASA use. Budesonide foam was efficacious and safe for induction of remission of mild to moderate ulcerative proctitis and ulcerative proctosigmoiditis in patients receiving oral 5-ASA at baseline and those who were not (Clinicaltrials.gov: NCT01008410 and NCT01008423).
Fact Sheet: Final Air Toxics Standards for Area Sources in Seven Industry Sectors
This fact sheet discusses national emission standards for acrylic and modacrylic fibers production, carbon black production, chemical manufacturing: chromium compounds, flexible polyurethane foam production and fabrication, lead acid battery manufacturing,
Superabsorbent biphasic system based on poly(lactic acid) and poly(acrylic acid)
NASA Astrophysics Data System (ADS)
Sartore, Luciana; Pandini, Stefano; Baldi, Francesco; Bignotti, Fabio
2016-05-01
In this research work, biocomposites based on crosslinked particles of poly(acrylic acid), commonly used as superabsorbent polymer (SAP), and poly-L-lactic acid (PLLA) were developed to elucidate the role of the filler (i.e., polymeric crosslinked particles) on the overall physico-mechanical behavior and to obtain superabsorbent thermoplastic products. Samples prepared by melt-blending of components in different ratios showed a biphasic system with a regular distribution of particles, with diameter ranging from 5 to 10 μm, within the PLLA polymeric matrix. The polymeric biphasic system, coded PLASA i.e. superabsorbent poly(lactic acid), showed excellent swelling properties, demonstrating that cross-linked particles retain their superabsorbent ability, as in their free counterparts, even if distributed in a thermoplastic polymeric matrix. The thermal characteristics of the biocomposites evidence enhanced thermal stability in comparison with neat PLLA and also mechanical properties are markedly modified by addition of crosslinked particles which induce regular stiffening effect. Furthermore, in aqueous environments the particles swell and are leached from PLLA matrix generating very high porosity. These new open-pore PLLA foams, produced in absence of organic solvents and chemical foaming agents, with good physico-mechanical properties appear very promising for several applications, for instance in tissue engineering for scaffold production.
NASA Astrophysics Data System (ADS)
Rubino, Caroline
Microleakage may be a factor in the progression of peri-implant pathology. Microleakage in implant dentistry refers to the passage of bacteria, fluids, molecules or ions between the abutment-implant interface to and from the surrounding periodontal tissues. This creates a zone of inflammation and reservoir of bacteria at the implant-abutment interface. Bone loss typically occurs within the first year of abutment connection and then stabilizes. It has not yet been definitively proven that the occurrence of microleakage cannot contribute to future bone loss or impede the treatment of peri-implant disease. Therefore, strategies to reduce or eliminate microleakage are sought out. Recent evidence demonstrates that the type of implant abutment channel occluding material can affect the amount of microleakage in an in vitro study environment. Thus, we hypothesize that different abutment screw channel occluding materials will affect the amount of observed microleakage, vis-a-vis the correlation between the microflora found on the abutment screw channel occluding material those found in the peri-implant sulcus. Additional objectives include confirming the presence of microleakage in vivo and assessing any impact that different abutment screw channel occluding materials may have on the peri-implant microbiome. Finally, the present study provides an opportunity to further characterize the peri-implant microbiome. Eight fully edentulous patients restored with at dental implants supporting screw-retained fixed hybrid prostheses were included in the study. At the initial appointment (T1), the prostheses were removed and the implants and prostheses were cleaned. The prostheses were then inserted with polytetrafluoroethylene tape (PTFE, TeflonRTM), cotton, polyvinyl siloxane (PVS), or synthetic foam as the implant abutment channel occluding material and sealed over with composite resin. About six months later (T2), the prostheses were removed and the materials collected. Paper points were used to sample the peri-implant sulcus bacteria. All samples were then submitted to DNA purification, polymerase chain reaction (PCR), and sequencing protocols to assess relative numbers of bacterial species. Periodontal parameters were collected at both time points. Overall, our findings support several conclusions. Different implant abutment channel occluding materials appear to have no effect on the amount of observed microleakage and the peri-implant microbiome. Evidence for microleakage was found in the present study, corroborating existing in vivo evidence. Finally, we gained several insights regarding the peri implant microbiome. Of note, the peri-implant microbiome is well described by the classical periodontal microbial complexes, but a large portion consists of bacteria not previously classified into the microbial complexes.
Zablotsky, M; Meffert, R; Mills, O; Burgess, A; Lancaster, D
1992-12-01
The purpose of this research was to determine the nature of the residual hydroxyapatite (HA)-coated implant surface after treatment with various chemotherapeutic modalities, including: citric acid, chlorhexidine gluconate, hydrogen peroxide, tetracycline HCl, stannous fluoride, polymyxin B and a prototype plastic Cavitron tip. Implant surfaces were evaluated macroscopically, microscopically (scanning electron microscopy (SEM)) and spectrometrically (energy-dispersive spectrometry and X-ray diffraction). HA-substrate bond strength and dissolution testing was also performed for surfaces treated with a supersaturated citric acid solution. All treatments left either microscopic residues or a loss of surface roughness when viewed on SEM. A 30- to 60-s application of citric acid left a significantly greater coating thickness than all other treatments, whereas a 3-min application of citric acid removed significantly more HA than untreated controls. Significant changes in Ca/P ratios were seen with most treatments. The clinical significance of this phenomenon is not known. No treatments altered the crystallinity of the residual HA coating. A 1-min application of citric acid did not significantly alter the tensile bond strength of the coating to the substrate. The clinical significance of these findings is not known at present. However, when taken with results from previous studies, it appears that in treating the infected HA-coated implant surface, a 30- to 60-s application of citric acid (pH 1) may be beneficial in detoxifying the HA coating prior to regenerative procedures. Further in vitro and in vivo studies are necessary to evaluate the biological response to citric acid when used to detoxify the infected implant surface.
Rosen, Paul S; Rosen, Adam D
2013-01-01
This retrospective case series reports on the use of a polylactic acid barrier that was left exposed in the process of socket preparation for the placement of dental implants. A retrospective chart review found 43 patients with 48 extraction sockets that were treated in this manner. Teeth were removed and the sockets were thoroughly debrided, with 40 of them receiving a bone replacement graft covered by the polylactic acid barrier and the additional 8 receiving the membrane alone. Suturing left the barrier exposed, and the sites were re-entered on average at 23 weeks for the placement of a dental implant. All sites were able to receive a dental implant, demonstrating the ability to leave a polylactic acid barrier exposed and achieve successful guided bone regeneration (GBR) results. This ultimately helped avoid some of the negative sequelae of trying to achieve primary closure of the flaps at the time of tooth extraction.
Latorres, J M; Rios, D G; Saggiomo, G; Wasielesky, W; Prentice-Hernandez, C
2018-02-01
Protein hydrolysates from white shrimp ( Litopenaeus vannamei ) with different degrees of hydrolysis (DH-10 and 20%) were prepared using the enzymes Alcalase 2.4 L and Protamex. The hydrolysates were evaluated for amino acid composition, solubility, foaming properties, emulsifying and antioxidant activity. All the hydrolysates showed high concentrations of Glutamic Acid, Aspartic acid, Arginine, Glycine, Lysine, Proline. It was found that the increase in the production of negatively charged amino acids was related to increase in DH. The hydrophobic amino acids were higher for hydrolysates obtained with Alcalase (10% DH) and Protamex (20% DH). The results indicated that higher degree of hydrolysis showed positive relation with the protein solubility of the hydrolysates, while negatively influenced foam and emulsification properties. The antioxidant properties presented by the white shrimp protein hydrolysates were influenced by the composition and peptides size. Hydrolysates with higher peptide chain showed the highest antioxidant power for the 2,2-Diphenyl-1-picrylhydrazyl radical scavenging and reducing power, while hydrolysates with lower peptide chain showed higher antioxidant power for 2,2'-azinobis (3-ethylbenzothiazoline sulfonic acid) radical scavenging. All hydrolysates showed dose-dependent antioxidant activities. Therefore, the results of the present study suggest that white shrimp is a potential source of protein hydrolysates as bioactive ingredients for the use in the formulation of functional foods as well as natural antioxidants in lipid food systems.
LPA3-mediated lysophosphatidic acid signalling in implantation and embryo spacing
Ye, Xiaoqin; Hama, Kotaro; Contos, James J.A.; Anliker, Brigitte; Inoue, Aska; Skinner, Michael K.; Suzuki, Hiroshi; Amano, Tomokazu; Kennedy, Grace; Arai, Hiroyuki; Aoki, Junken; Chun, Jerold
2005-01-01
Every successful pregnancy requires proper embryo implantation. Low implantation rate is a major problem during infertility treatments using assisted reproductive technologies (ART) 1. Here we report a new molecular influence on implantation through the lysophosphatidic acid (LPA) receptor LPA3 2–4. Targeted deletion of LPA3 in mice resulted in significantly reduced litter size, which could be attributed to delayed implantation and altered embryo spacing. These two events led to delayed embryonic development, hypertrophic placentas shared by multiple embryos, and embryonic death. An enzyme demonstrated to influence implantation, cyclooxygenase-2 (COX-2) 5, was down-regulated in LPA3-deficient uteri during preimplantation. Down regulation of COX-2 led to reduced levels of prostaglandins that are critical for implantation 1. Exogenous administration of the prostaglandins PGE2 and cPGI into LPA3-deficient females rescued delayed implantation but did not rescue defects in embryo spacing. These data identify LPA3 receptor-mediated signalling as a new influence on implantation and further indicate linkage between LPA signalling and prostaglandin biosynthesis. PMID:15875025
Human fetal bone cells in delivery systems for bone engineering.
Tenorio, Diene M H; Scaletta, Corinne; Jaccoud, Sandra; Hirt-Burri, Nathalie; Pioletti, Dominique P; Jaques, Bertrand; Applegate, Lee Ann
2011-11-01
The aim of this study was to culture human fetal bone cells (dedicated cell banks of fetal bone derived from 14 week gestation femurs) within both hyaluronic acid gel and collagen foam, to compare the biocompatibility of both matrices as potential delivery systems for bone engineering and particularly for oral application. Fetal bone cell banks were prepared from one organ donation and cells were cultured for up to 4 weeks within hyaluronic acid (Mesolis®) and collagen foams (TissueFleece®). Cell survival and differentiation were assessed by cell proliferation assays and histology of frozen sections stained with Giemsa, von Kossa and ALP at 1, 2 and 4 weeks of culture. Within both materials, fetal bone cells could proliferate in three-dimensional structure at ∼70% capacity compared to monolayer culture. In addition, these cells were positive for ALP and von Kossa staining, indicating cellular differentiation and matrix production. Collagen foam provides a better structure for fetal bone cell delivery if cavity filling is necessary and hydrogels would permit an injectable technique for difficult to treat areas. In all, there was high biocompatibility, cellular differentiation and matrix deposition seen in both matrices by fetal bone cells, allowing for easy cell delivery for bone stimulation in vivo. Copyright © 2011 John Wiley & Sons, Ltd.
Raman-based imaging uncovers the effects of alginate hydrogel implants in spinal cord injury
NASA Astrophysics Data System (ADS)
Galli, Roberta; Tamosaityte, Sandra; Koch, Maria; Sitoci-Ficici, Kerim H.; Later, Robert; Uckermann, Ortrud; Beiermeister, Rudolf; Gelinsky, Michael; Schackert, Gabriele; Kirsch, Matthias; Koch, Edmund; Steiner, Gerald
2015-07-01
The treatment of spinal cord injury by using implants that provide a permissive environment for axonal growth is in the focus of the research for regenerative therapies. Here, Raman-based label-free techniques were applied for the characterization of morphochemical properties of surgically induced spinal cord injury in the rat that received an implant of soft unfunctionalized alginate hydrogel. Raman microspectroscopy followed by chemometrics allowed mapping the different degenerative areas, while multimodal multiphoton microscopy (e.g. the combination of coherent anti-Stokes Raman scattering (CARS), endogenous two-photon fluorescence and second harmonic generation on the same platform) enabled to address the morphochemistry of the tissue at cellular level. The regions of injury, characterized by demyelination and scarring, were retrieved and the distribution of key tissue components was evaluated by Raman mapping. The alginate hydrogel was detected in the lesion up to six months after implantation and had positive effects on the nervous tissue. For instance, multimodal multiphoton microscopy complemented the results of Raman mapping, providing the micromorphology of lipid-rich tissue structures by CARS and enabling to discern lipid-rich regions that contained myelinated axons from degenerative regions characterized by myelin fragmentation and presence of foam cells. These findings demonstrate that Raman-based imaging methods provide useful information for the evaluation of alginate implant effects and have therefore the potential to contribute to new strategies for monitoring degenerative and regenerative processes induced in SCI, thereby improving the effectiveness of therapies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Canbazoglu, F. M.; Fan, B.; Kargar, A.
2016-08-15
The relative influence of the capillary, Marangoni, and hydrophobic forces in mediating the evaporation of water from carbon foam based porous media, in response to incident solar radiation, are investigated. It is indicated that inducing hydrophilic interactions on the surface, through nitric acid treatment of the foams, has a similar effect to reduced pore diameter and the ensuing capillary forces. The efficiency of water evaporation may be parameterized through the Capillary number (Ca), with a lower Ca being preferred. The proposed study is of much relevance to efficient solar energy utilization.
Sprincl, L; Terescenko, T L; Kálal, J; Lipatova, T E; Kopecek, J; Pchakadze, G A
1976-01-01
The biocompatibility of three types of hydrophilic poly-(glycol methacrylate) gels--homogeneous, microporous and macroporous--was investigated in an experimental subcutaneous implantation. The occurrence of mucopolysaccharide complexes formed by both hyaluronic acid and chondroitine sulphates was examined in the fibrous tissue which surrounds the implant and penetrates into it in the case of a macroporous polymer. In an early stage of investigation hyaluronic acid prevails, but with proceeding collagenization the chondroitine sulphate part becomes predominant.
Ibañez, Juan C; Tahhan, Marcelo J; Zamar, Juan A; Menendez, Alicia B; Juaneda, Agustina M; Zamar, Nicolas J; Monqaut, Jose L
2005-11-01
The high success rate of dental implants has changed the quality of life for many patients. Immediate loading finds its application in some clinical cases and certainly adds another modality of treatment for the implant patient. Starting with a few implants immediately loaded with a bar overdenture in the mandible, the concept of immediate loading evolved to loading multiple implants in both the maxilla and mandible. In this investigation, 41 consecutive patients who needed full-arch restorations were treated with 343 double acid-etched surface implants between May 1998 and March 2004. The sample included smokers and bruxers. Twenty-three mandibular and 26 maxillary cases were treated, loading the implants within 48 hours, by using resin provisional prostheses, metal-reinforced provisional prostheses, or definitive prostheses (metal-acrylic or metal-ceramic). All implants were followed for 12 to 74 months. Follow-up consisted of clinical as well as radiographic examination. Furthermore, resonance frequency analysis was done in most of the implants during the last 2 years. The success rate obtained was 99.42% (only two mandibular implants that are still surviving were considered failures). The bone level was measured every year. The average radiographic bone level change was 0.56 mm at 12, 0.76 mm at 24, 0.84 mm at 36, 0.82 mm at 48, 0.83 mm at 60, and 0.94 mm at 72 months. A high success rate can be achieved when double acid-etched surface implants are immediately loaded with fixed full-arch restorations in the maxilla and mandible.
Min, Shao-xiong; Jin, An-min; Tong, Bin-hui; Zhu, Li-xin; Tian, Jing
2003-04-01
To investigate the osteoinductive ability of the composites consisting of basic fibroblast growth factor (bFGF) and porous poly-DL-lactide (PDLLA) for the development of a new absorbable osteosynthesis material. Highly porous foams of PDLLA with the pore size ranging from 150 to 300 microm were prepared by a solvent-casting, particulate-leaching technique with NaCl as the leachable component. Animal models of radial diaphyseal defects of 1.0 cm with complete removal of the periosteum were induced in 45 rabbits, which were randomly divided into 3 groups to receive the defect repair with PDLLA and PDLLA/bFGF respectively, leaving one group untreated to serve as the control group. The implant specimens were harvested at 2, 4, 8, and 12 weeks respectively after the surgery and X-ray, histological and scanning electron microscopic (SEM) examinations were performed to evaluate the effectiveness of defect repair. At 8 and 12 weeks after implantation, biomechanical test (for three-point bending strength) was employed to study the quality of bone formation. PDLLA/bFGF composite stimulated more bone formation and had higher bending strength than PDLLA (P<0.05), and the bone formation induced by both materials was significantly more than that observed in the control group in every postoperative stage (P<0.05). PDLLA possesses good biocompatibility and absorbability, and when prepared into a porous material, it exhibits good osteoconductibility. As a good bFGF carrier, the foam of PDLLA with three- dimensional structure shows good osteoinductive ability with regard to the rapidity, quantity and quality of the bone formation.
Pettes, Michael Thompson; Ji, Hengxing; Ruoff, Rodney S; Shi, Li
2012-06-13
At a very low solid concentration of 0.45 ± 0.09 vol %, the room-temperature thermal conductivity (κ(GF)) of freestanding graphene-based foams (GF), comprised of few-layer graphene (FLG) and ultrathin graphite (UG) synthesized through the use of methane chemical vapor deposition on reticulated nickel foams, was increased from 0.26 to 1.7 W m(-1) K(-1) after the etchant for the sacrificial nickel support was changed from an aggressive hydrochloric acid solution to a slow ammonium persulfate etchant. In addition, κ(GF) showed a quadratic dependence on temperature between 11 and 75 K and peaked at about 150 K, where the solid thermal conductivity (κ(G)) of the FLG and UG constituents reached about 1600 W m(-1) K(-1), revealing the benefit of eliminating internal contact thermal resistance in the continuous GF structure.
A macro- and nanostructure evaluation of a novel dental implant.
Tetè, Stefano; Mastrangelo, Filiberto; Traini, Tonino; Vinci, Raffaele; Sammartino, Gilberto; Marenzi, Gaetano; Gherlone, Enrico
2008-09-01
Success in implant dentistry also comes from the implant macrodesign and nanostructure of its surface. Titanium implant surface treatments have been shown to enhance osseointegration, maximize bone healing, and bone-to-implant contact for predictable clinical results. The aim of the study, was to evaluate the geometric macrodesign and the surface nanostructure of a novel dental implant full contact covering (FCC) obtained by electrochemical procedures. FCC implants were analyzed by scanning electronic microscope, profilometer, and x-ray photoelectron spectroscopy and compared with commercial sandblasted and sandblasted, large-grit acid-etched dental implants. Sample analysis allowed to distinguish the different implant macrodesigns, the step and the profile of the coils that cover the fixture, and the surface characteristics. FCC implant showed novel macro-characteristic of crestal module, coils, and apical zone compared with sandblasted and sandblasted and acid-etched dental implants. Moreover, the FCC nanostructure surface showed roughness values statistically higher than the 2 other surfaces, with a more homogeneity in a peaks and valleys arrangement. Finally, the x-ray photoelectron spectroscopy analysis detected differences between the examined surfaces, with the presence of several contaminants according to the different treatment procedures. Research on new macrostructures and nano morphology should result in a better qualitative and quantitative osseointegration response, with a predictability of the clinical results and long-term success of the implants.
Barber, Thomas A; Ho, James E; De Ranieri, Aladino; Virdi, Amarjit S; Sumner, Dale R; Healy, Kevin E
2007-02-01
Interpenetrating polymer networks (IPNs) of poly (acrylamide-co-ethylene glycol/acrylic acid) functionalized with an -Arg-Gly-Asp- (RGD) containing 15 amino acid peptides, derived from rat bone sialoprotein (bsp-RGD(15), were grafted to titanium implants in an effort to modulate bone formation in the peri-implant region in the rat femoral ablation model. Bone-implant contact (BIC) and bone formation within the medullary canal were determined using microcomputed tomography at 2 and 4 weeks postimplantation. BIC for bsp-RGD(15)-IPN implants was enhanced relative to hydroxyapatite tricalcium phosphate (HA-TCP) coated implants, but was similar to all other groups. Aggregate bone formation neither indicated a dose-dependent effect of bsp-RGD(15) nor a meaningful trend. Mechanical testing of implant fixation revealed that only the HA-TCP coated implants supported significant (>1 MPa) interfacial shear strength, despite exhibiting lower overall BIC, an indication that bone ingrowth into the rougher coating was the primary mode of implant fixation. While no evidence was found to support the hypothesis that bsp-RGD(15)-modified IPN coated implants significantly impacted bone-implant bonding, these results point to the lack of correlation between in vitro studies employing primary osteoblasts and in vivo wound healing in the peri-implant region. Copyright 2006 Wiley Periodicals, Inc.
Galvez-Rongel, A; Ezquerra-Brauer, J M; Ocano-Higuera, V M; Ramirez-Wong, B; Torres-Arreola, W; Rouzaud-Sandez, O; Marquez-Rios, E
2014-03-01
Jumbo squid is an important fishery resource in Mexico, and its muscle is lean and white and it has a very low price in the market. It is abundant, but with little or nothing added value, therefore is necessary to search alternatives of processing. Due to muscle characteristics, the aim of this study was to obtain protein concentrates using different methods. They were obtained by means of acidic (acid protein concentrates) and alkaline (alkaline protein concentrates) dissolution. Moreover, a protein concentrate was obtained by direct isoelectric precipitation and by the traditional method (neutral protein concentrates). The yield with better results was alkaline protein concentrates (63.58 ± 1.8%). The gel hardness was significantly different (p < 0.05), especially for the alkaline protein concentrates. The acid protein concentrates, isoelectric precipitation and alkaline protein concentrates were better with regard to the neutral protein concentrates, concerning the emulsifying and foaming properties. The protein concentrates by means of alkaline dissolution gave a better gelling property, but all the processes had the potential to obtain protein with emulsifying and foaming properties.
NASA Astrophysics Data System (ADS)
Li, Wen; Wang, Tao; Yang, Yingge; Liu, Dan; Fan, Yonghong; Wang, Dongmei; Yang, Qian; Yao, Jianming; Zheng, Zhiming; Yu, Zengliang
2008-04-01
In order to get an industrial strain which can yield a high concentration of lactic acid for ISPR (in situ product removal), the original strain Rhizopus oryzae RE3303 was mutated by low-energy ion beam implantation. A mutant RK02 was screened, and the factors such as the substrate concentration, nitrogen source concentration, inoculum size, seed age, aeration and temperature that affect the production of lactic acid were studied in detail. Under optimal conditions, the maximum concentration of L(+)-lactic acid reached 34.85 g/L after 30 h shake-flask cultivation without adding any neutralisation (5% Glucose added), which was a 146% increase in lactic acid production after ion implantation compared with the original strain. It was also shown that RK02 can be used in ISPR to reduce the number of times of separation.
Solid intraocular xanthogranuloma in three Miniature Schnauzer dogs.
Zarfoss, Mitzi K; Dubielzig, Richard R
2007-01-01
Macrophages that contain abundant intracytoplasmic lipid are called 'foam cells'. In four canine globes submitted to the Comparative Ocular Pathology Laboratory of Wisconsin (COPLOW), foam cells formed a solid intraocular mass. The purpose of this study was to describe the histopathologic findings in these cases. The electronic COPLOW database (1993-2006) was searched for the diagnosis of 'foam cell tumor'. Clinical history, gross pathology and histopathology (5-micron sections, hematoxylin and eosin and Alcian blue periodic acid Schiff) were reviewed in all cases. Cases were included if the globe was grossly filled by a solid mass and if all intraocular structures were effaced by lipid-laden foam cell macrophages admixed with birefringent, Alcian blue-positive crystals oriented in stellate patterns. All three patients (four globes) satisfying the selection criteria were Miniature Schnauzers. In all cases the clinical history included diabetes mellitus, hyperlipidemia and chronic bilateral uveitis that was interpreted to be lens-induced. All globes were enucleated because of glaucoma. The term solid intraocular xanthogranuloma was used to describe these cases because the intraocular contents were effaced by a solid mass of foam cells and birefringent crystals. The cases in this report suggest that diabetic Miniature Schnauzers with hyperlipidemia are at risk for lipid and macrophage-rich uveitis, which may in some cases form a solid inflammatory intraocular mass, precipitate glaucoma, and lead to enucleation.
Hrynets, Yuliya; Omana, Dileep A; Xu, Yan; Betti, Mirko
2010-09-01
Functional and rheological characteristics of acid- and alkali-extracted proteins from mechanically separated turkey meat (MSTM) have been investigated. Extractions were carried out at 4 pH values (2.5, 3.5, 10.5, and 11.5). The study demonstrated that alkali and acid extractions resulted in significant (P < 0.0001) decreases of cooking and water loss compared to raw MSTM; however, the cooking loss was found to be similar (P = 0.5699) among the different protein isolates. Proteins extracted at pH 10.5 showed the lowest (P = 0.0249) water loss. Emulsion and foaming properties were found to be slightly higher in alkali-extracted proteins compared to those for acid extractions. The myofibrillar protein fraction showed better ability to form and stabilize emulsions compared to sarcoplasmic proteins. Myofibrillar proteins also showed better foam expansion; however, foam volume stability was similar for both myofibrillar and sarcoplasmic protein fractions. Textural characteristics (hardness, chewiness, springiness, and cohesiveness) of recovered proteins were found to be unaffected (P > 0.05) by different extraction pH. The protein extracted at pH 3.5 formed a highly viscoelastic gel network as evidenced by storage modulus (G') values, whereas the gel formed from proteins extracted at pH 10.5 was found to be the weakest. The work also revealed that acid treatments were more effective for removal of total heme pigments from MSTM. Color characteristics of protein isolates were markedly improved compared to the initial material and tended to be better when subjected to acid extractions. Mechanically separated meat is one of the cheapest sources of protein obtained by grinding meat and bones together and forcing the mixture through a perforated drum. The use of mechanically separated turkey meat (MSTM) for the production of further processed poultry products is limited due to its undesirable color and textural properties. Recovery of proteins from MSTM using pH shifting process will help the poultry processors to get better returns and also create opportunity to produce functional food ingredients.
Xu, Ting-Ting; Bai, Zhong-Zhong; Wang, Li-Juan; He, Bing-Fang
2010-01-01
The low-energy nitrogen ion beam implantation technique was used in the breeding of mutant D(-)-lactic-acid-producing strains. The wild strain Sporolactobacillus sp. DX12 was mutated by an N(+) ion beam with energy of 10keV and doses ranging from 0.4 x 10(15) to 6.60 x 10(15) ions/cm(2). Combined with an efficient screening method, an efficient mutant Y2-8 was selected after two times N(+) ion beam implantation. By using the mutant Y2-8, 121.6g/l of D-lactic acid was produced with the molar yields of 162.1% to the glucose. The yield of D-lactic acid by strain Y2-8 was 198.8% higher than the wild strain. Determination of anaerobic metabolism by Biolog MT2 was used to analyze the activities of the concerned enzymes in the lactic acid metabolic pathway. The results showed that the activities of the key enzymes responded on the substrates such as 6-phosphofructokinase, pyruvate kinase, and D-lactate dehydrogenase were considerably higher in the mutants than the wild strain. These might be affected by ion beam implantation.
NASA Astrophysics Data System (ADS)
Kumar, Rajeev; Kumari, Saroj; Mathur, Rakesh B.; Dhakate, Sanjay R.
2015-01-01
In the present study, nanostructuring effect of multi-walled carbon nanotubes (MWCNTs) on electrochemical properties of coal tar pitch (CTP) based carbon foam (CFoam) was investigated. The different weight fractions of MWCNTs were mixed with CTP and foam was developed from the mixture of CTP and MWCNTs by sacrificial template technique and heat treated at 1,400 and 2,500 °C in inert atmosphere. These foams were characterized by scanning electron microscopy, X-ray diffraction, and potentiostat PARSTAT for cyclic voltammetry. It was observed that, bulk density of CFoam increases with increasing MWCNTs content and decreases after certain amount. The MWCNTs influence the morphology of CFoam and increase the width of ligaments as well as surface area. During the heat treatment, stresses exerting at MWCNTs/carbon interface accelerate ordering of the graphene layer which have positive effect on the electrochemical properties of CFoam. The current density increases from 475 to 675 mA/cm2 of 1,400 °C heat treated and 95 to 210 mA/cm2 of 2,500 °C heat-treated CFoam with 1 wt% MWCNTs. The specific capacitance was decreases with increasing the scan rate from 100 to 1,000 mV/s. In case of 1 % MWCNTs content CFoam the specific capacitance at the scan rate 100 mV/s was increased from 850 to 1,250 μF/cm2 and 48 to 340 μF/cm2 of CFoam heat treated at 1,400 °C and 2,500 °C respectively. Thus, the higher value surface area and current density of MWCNTs-incorporated CFoam heat treated to 1,400 °C can be suitable for lead acid battery electrode with improved charging capability.
Piattelli, Adriano; Quaranta, Alesandro
2017-01-01
Background Scientific evidence in the field of implant dentistry of the past 20 years established that titanium rough surfaces have shown improved osseointegration rates. In a majority of dental implants, the surface microroughness was obtained by grit blasting and/or acid etching. The aim of the study was to evaluate in vivo two different highly hydrophilic surfaces at different experimental times. Methods Calcium-modified (CA) and SLActive surfaces were evaluated and a total of 18 implants for each type of surface were positioned into the rabbit articular femoral knee-joint in a split model experiment, and they were evaluated histologically and histomorphometrically at 15, 30, and 60 days of healing. Results Bone-implant contact (BIC) at the two-implant surfaces was significantly different in favor of the CA surface at 15 days (p = 0.027), while SLActive displayed not significantly higher values at 30 (p = 0.51) and 60 days (p = 0.061). Conclusion Both implant surfaces show an intimate interaction with newly formed bone. PMID:29445746
Nieuwoudt, Melanie; Lombard, Nicolaas; Rautenbach, Marina
2014-08-15
In beer brewing, brewers worldwide strive to obtain product consistency in terms of flavour, colour and foam. Important proteins contributing to beer foam are lipid transfer proteins (LTPs), in particular LTP1 and its lipid-bound isoform LTP1b, which are known to transport lipids in vivo and prevent lipids from destabilising the beer foam. LTP1 and LTP1b were successfully purified using only five purification steps with a high purified protein yield (160 mg LTP1 and LTP1b from 200 g barley). Circular dichroism of LTP1 and LTP1b confirmed that both proteins are highly tolerant to high temperatures (>90 °C) and are pH stable, particularly at a neutral to a more basic pH. Only LTP1 exhibited antiyeast and thermo-stable lytic activity, while LTP1b was inactive, indicating that the fatty acid moiety compromised the antimicrobial activity of LTP1. This lack in antiyeast activity and the positive foam properties of LTP1b would benefit beer fermentation and quality. Copyright © 2014 Elsevier Ltd. All rights reserved.
Cavalcante Hissa, Denise; Arruda Bezerra, Gustavo; Birner-Gruenberger, Ruth; Paulino Silva, Luciano; Usón, Isabel; Gruber, Karl; Maciel Melo, Vânia Maria
2014-02-10
Breeding by releasing eggs into stable biofoams ("foam nests") is a peculiar reproduction mode within anurans, fish, and tunicates; not much is known regarding the biochemistry or molecular mechanisms involved. Lv-ranaspumin (Lv-RSN-1) is the predominant protein from the foam nest of the frog Leptodactylus vastus. This protein shows natural surfactant activity, which is assumed to be crucial for stabilizing foam nests. We elucidated the amino acid sequence of Lv-RSN-1 by de novo sequencing with mass-spectrometry and determined the high-resolution X-ray structure of the protein. It has a unique fold mainly composed of a bundle of 11 α-helices and two small antiparallel β-strands. Lv-RSN-1 has a surface rich in hydrophilic residues and a lipophilic cavity in the region of the antiparallel β-sheet. It possesses intrinsic surface-active properties, reducing the surface tension of water from 73 to 61 mN m(-1) (15 μg mL(-1)). Lv-RSN-1 belongs to a new class of surfactants proteins for which little has been reported regarding structure or function. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Emerging technologies in arthroplasty: additive manufacturing.
Banerjee, Samik; Kulesha, Gene; Kester, Mark; Mont, Michael A
2014-06-01
Additive manufacturing is an industrial technology whereby three-dimensional visual computer models are fabricated into physical components by selectively curing, depositing, or consolidating various materials in consecutive layers. Although initially developed for production of simulated models, the technology has undergone vast improvements and is currently increasingly being used for the production of end-use components in various aerospace, automotive, and biomedical specialties. The ability of this technology to be used for the manufacture of solid-mesh-foam monolithic and coated components of complex geometries previously considered unmanufacturable has attracted the attention of implant manufacturers, bioengineers, and orthopedic surgeons. Currently, there is a paucity of reports describing this fabrication method in the orthopedic literature. Therefore, we aimed to briefly describe this technology, some of the applications in other orthopedic subspecialties, its present use in hip and knee arthroplasty, and concerns with the present form of the technology. As there are few reports of clinical trials presently available, the true benefits of this technology can only be realized when studies evaluating the clinical and radiographic outcomes of cementless implants manufactured with additive manufacturing report durable fixation, less stress shielding, and better implant survivorship. Nevertheless, the authors believe that this technology holds great promise and may potentially change the conventional methods of casting, machining, and tooling for implant manufacturing in the future. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Characterization of Porous, Dexamethasone-Releasing Polyurethane Coatings for Glucose Sensors
Vallejo-Heligon, Suzana G.; Klitzman, Bruce; Reichert, William M.
2014-01-01
Commercially available implantable needle-type glucose sensors for diabetes management are robust analytically but can be unreliable clinically primarily due to tissue-sensor interactions. Here, we present the physical, drug release, and bioactivity characterization of tubular, porous dexamethasone (Dex) releasing polyurethane coatings designed to attenuate local inflammation in the tissue-sensor interface. Porous polyurethane coatings were produced by the salt-leaching/gas-foaming method. Scanning electron microscopy (SEM) and Micro-computed tomography (Micro-CT) showed a controlled porosity and coating thickness. In vitro drug release from coatings monitored over two weeks presented an initial fast release followed by a slower release. Total release from coatings was highly dependent on initial drug loading amount. Functional in vitro testing of glucose sensors deployed with porous coatings against glucose standards demonstrated that highly porous coatings minimally affected signal strength and response rate. Bioactivity of the released drug was determined by monitoring Dex-mediated, dose-dependent apoptosis of human peripheral blood derived monocytes in culture. Acute animal studies were used to determine the appropriate Dex payload for the implanted porous coatings. Pilot short-term animal studies showed that Dex released from porous coatings implanted in rat subcutis attenuated the initial inflammatory response to sensor implantation. These results suggest that deploying sensors with the porous, Dex-releasing coatings is a promising strategy to improve glucose sensor performance. PMID:25065548
NASA Astrophysics Data System (ADS)
Zheng, Guoyan
2007-03-01
Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.
Diefenbeck, M; Schrader, C; Gras, F; Mückley, T; Schmidt, J; Zankovych, S; Bossert, J; Jandt, K D; Völpel, A; Sigusch, B W; Schubert, H; Bischoff, S; Pfister, W; Edel, B; Faucon, M; Finger, U
2016-09-01
Implant related infection is one of the most feared and devastating complication associated with the use of orthopaedic implant devices. Development of anti-infective surfaces is the main strategy to prevent implant contamination, biofilm formation and implant related osteomyelitis. A second concern in orthopaedics is insufficient osseointegration of uncemented implant devices. Recently, we reported on a macroporous titanium-oxide surface (bioactive TiOB) which increases osseointegration and implant fixation. To combine enhanced osseointegration and antibacterial function, the TiOB surfaces were, in addition, modified with a gentamicin coating. A rat osteomyelitis model with bilateral placement of titanium alloy implants was employed to analyse the prophylactic effect of gentamicin-sodiumdodecylsulfate (SDS) and gentamicin-tannic acid coatings in vivo. 20 rats were randomly assigned to four groups: (A) titanium alloy; PBS inoculum (negative control), (B) titanium alloy, Staphylococcus aureus inoculum (positive control), (C) bioactive TiOB with gentamicin-SDS and (D) bioactive TiOB plus gentamicin-tannic acid coating. Contamination of implants, bacterial load of bone powder and radiographic as well as histological signs of implant-related osteomyelitis were evaluated after four weeks. Gentamicin-SDS coating prevented implant contamination in 10 of 10 tibiae and gentamicin-tannic acid coating in 9 of 10 tibiae (infection prophylaxis rate 100% and 90% of cases, respectively). In Group (D) one implant showed colonisation of bacteria (swab of entry point and roll-out test positive for S. aureus). The interobserver reliability showed no difference in the histologic and radiographic osteomyelitis scores. In both gentamicin coated groups, a significant reduction of the histological osteomyelitis score (geometric mean values: C = 0.111 ± 0.023; D = 0.056 ± 0.006) compared to the positive control group (B: 0.244 ± 0.015; p < 0.05) was observed. The radiographic osteomyelitis scores confirmed these histological findings. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Oppermann, Dean Alan
Magnetically directed chondrogenesis (MDC) is a fundamental approach to articular cartilage repair. In MDC a magnet is implanted into the subchondral trabecular bone underlying a cartilage defect and used to attract chondrocytes, magnetically tagged with Fe nanoparticles, to the defect site. Pilot studies by Halpern, Crimp and Grande, using solid neodymium (Nd) magnets, indicated optimistic results by producing a hyaline-like articular cartilage after 8 weeks implantation. Since solid Nd magnets introduce long-term biocompatibility issues, the focus of this dissertation was to develop P(dl)A/PGA/Fe and P(dl)A/PGA/SmCo 5 implants for use in MDC. The effect of implant porosity, implant composition and magnetic material (Fe or SmCo5) on the initial and degraded magnetic properties were evaluated. The biocompatibility of P(dl)A/PGA/Fe implants were investigated by implantation into New Zealand white rabbits for 8 weeks. The effect of hydrogen peroxide (H2O2) and ethylene oxide (EO) sterilization techniques on the molecular weight and chemical structure of P(dl)A/PGA polymers were evaluated using gel permeation chromatography and Fourier transform infrared spectroscopy. The effect of implant morphology, size and number on the von Mises stress in the trabecular bone surrounding the implant was evaluated using a finite element model. In general, SmCo5 implants resulted in higher magnetic fields initially and after 8 weeks of degradation than comparable Fe implants. Increases in magnetic field strength were achieved by increasing the volume fraction of magnetic material and by increasing the PGA concentration. The magnetic field strength degradation rate decreased with increases in volume fraction of magnetic material and increases in PLA concentration. Implantation studies indicated that 50/50 P(dl)A/PGA were more bioactive than 75/25 P(dl)A/PGA with an increased cellular response that is specific to bone growth. The compressive strength and elastic modulus of porous implants were comparable to trabecular bone, and the compressive strength and elastic modulus of solid implants was higher than trabecular bone but less than cortical bone. Finite element modeling showed that the implantation of solid and porous P(dl)A/PGA/Fe implants did not significantly increase the von Mises stress concentration adjacent to the implant. The von Mises stress surrounding porous implants was higher than the solid implants which predicts faster bone remodeling. Comparing single implants to multiple implants indicated a significant decrease in von Mises stress between the implants. This would predict bone resorption in that area. H2O2 sterilization resulted in a gradual decrease in the molecular weight of P(dl)A/PGA polymers that was a result of hydrolytic scission of the ester bonds present between the individual monomers. The polymers were less affected by EO sterilization with only the 75/25 P(dl)A/PGA, indicating a decrease in molecular weight. From these results, it was concluded that solid 50/50 P(dl)A/PGA/SmCo 5 implants that span the entire width of the cartilage defect should be used to optimize the attraction potential and bioactivity of the implant. Also ethylene oxide, which caused less premature implant degradation, should be used for sterilization.
Rao, X; Chu, C L; Zheng, Y Y
2014-06-01
Porous Ti-Nb-Zr alloys with different porosities from 6.06 to 62.8% are prepared by a two-step foaming powder metallurgy method using TiH2, Nb, and Zr powders together with 0 to 50wt% of NH4HCO3. The effects of the amounts of Nb and Zr as well as the sintering temperature (1473 to 1673K) on their phase composition, porosity, morphology, and mechanical characteristics are investigated. By controlling the porosity, Nb and Zr concentrations as well as the sintering temperature, porous Ti-Nb-Zr alloys with different mechanical properties can be obtained, for example, the hardness between 290 and 63HV, the compressive strength between 1530.5 and 73.4MPa, and the elastic modulus between 10.8 and 1.2GPa. The mechanical properties of the sintered porous Ti-Nb-Zr alloys can be tailored to match different requirements for the human bones and are thus potentially useful in the hard tissue implants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Studying the loading effect of acidic type antioxidant on amorphous silica nanoparticle carriers
NASA Astrophysics Data System (ADS)
Ravinayagam, Vijaya; Rabindran Jermy, B.
2017-06-01
The study investigates the suitable nanosilica carriers to transport acidic type cargo molecules for potential targeted drug delivery application. Using phenolic acidic type antioxidant gallic acid (GA) as model compound, the present study investigates the loading effect of GA (0.3-15.9 mmol GA g-1 support) on textural characteristics of amorphous silica nanoparticles such as Q10 silica (1D), structured two-dimensional Si-MCM-41 (2D), and three-dimensional Si-SBA-16 (3D). The variation in the nature of textures after GA loading was analyzed using X-ray diffraction, N2 adsorption, FT-IR, scanning electron microscopy with energy dispersive X-ray spectroscopy, and high-resolution transmission electron microscopy. Among the nanocarriers, high adsorption of GA was found in the following order: Si-SBA-16 (3D)˜Si-KIT-6 (3D) > Si-MCM-41 (2D) > ultralarge pore FDU-12 (ULPFDU-12; 3D) > Q10 (1D)˜mesostructured cellular silica foam (MSU-F). 3D-type silicas Si-SBA-16 and KIT-6 were shown to maintain structural integrity at acidic condition (pH ˜3) and accommodate GA in non-crystalline form. In the case of ULPFDU-12 and MSU-F cellular foam, only crystalline deposition of GA occurs with a significant variation in the surface area and pore volume. [Figure not available: see fulltext.
Grajeda-Iglesias, Claudia; Aviram, Michael
2018-06-20
The strong relationship between cardiovascular diseases (CVD), atherosclerosis, and endogenous or exogenous lipids has been recognized for decades, underestimating the contribution of other dietary components, such as amino acids, to the initiation of the underlying inflammatory disease. Recently, specific amino acids have been associated with incident cardiovascular disorders, suggesting their significant role in the pathogenesis of CVD. Special attention has been paid to the group of branched-chain amino acids (BCAA), leucine, isoleucine, and valine, since their plasma values are frequently found in high concentrations in individuals with CVD risk. Nevertheless, dietary BCAA, leucine in particular, have been associated with improved indicators of atherosclerosis. Therefore, their potential role in the process of atherogenesis and concomitant CVD development remains unclear. Macrophages play pivotal roles in the development of atherosclerosis. They can accumulate high amounts of circulating lipids, through a process known as macrophage foam cell formation, and initiate the atherogenesis process. We have recently screened for anti- or pro-atherogenic amino acids in the macrophage model system. Our study showed that glycine, cysteine, alanine, leucine, glutamate, and glutamine significantly affected macrophage atherogenicity mainly through modulation of the cellular triglyceride metabolism. The anti-atherogenic properties of glycine and leucine, and the pro-atherogenic effects of glutamine, were also confirmed in vivo. Further investigation is warranted to define the role of these amino acids in atherosclerosis and CVD, which may serve as a basis for the development of anti-atherogenic nutritional and therapeutic approaches.
Rossi, Eleonora; Gerges, Irini; Tocchio, Alessandro; Tamplenizza, Margherita; Aprile, Paola; Recordati, Camilla; Martello, Federico; Martin, Ivan; Milani, Paolo; Lenardi, Cristina
2016-10-01
Despite clinical treatments for adipose tissue defects, in particular breast tissue reconstruction, have certain grades of efficacy, many drawbacks are still affecting the long-term survival of new formed fat tissue. To overcome this problem, in the last decades, several scaffolding materials have been investigated in the field of adipose tissue engineering. However, a strategy able to recapitulate a suitable environment for adipose tissue reconstruction and maintenance is still missing. To address this need, we adopted a biologically and mechanically driven design to fabricate an RGD-mimetic poly(amidoamine) oligomer macroporous foam (OPAAF) for adipose tissue reconstruction. The scaffold was designed to fulfil three fundamental criteria: capability to induce cell adhesion and proliferation, support of in vivo vascularization and match of native tissue mechanical properties. Poly(amidoamine) oligomers were formed into soft scaffolds with hierarchical porosity through a combined free radical polymerization and foaming reaction. OPAAF is characterized by a high water uptake capacity, progressive degradation kinetics and ideal mechanical properties for adipose tissue reconstruction. OPAAF's ability to support cell adhesion, proliferation and adipogenesis was assessed in vitro using epithelial, fibroblast and endothelial cells (MDCK, 3T3L1 and HUVEC respectively). In addition, in vivo subcutaneous implantation in murine model highlighted OPAAF potential to support both adipogenesis and vessels infiltration. Overall, the reported results support the use of OPAAF as a scaffold for engineered adipose tissue construct. Copyright © 2016 Elsevier Ltd. All rights reserved.
2017-01-01
Purpose Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2. PMID:28680714
Scaling of titanium implants entrains inflammation-induced osteolysis
Eger, Michal; Sterer, Nir; Liron, Tamar; Kohavi, David; Gabet, Yankel
2017-01-01
With millions of new dental and orthopedic implants inserted annually, periprosthetic osteolysis becomes a major concern. In dentistry, peri-implantitis management includes cleaning using ultrasonic scaling. We examined whether ultrasonic scaling releases titanium particles and induces inflammation and osteolysis. Titanium discs with machined, sandblasted/acid-etched and sandblasted surfaces were subjected to ultrasonic scaling and we physically and chemically characterized the released particles. These particles induced a severe inflammatory response in macrophages and stimulated osteoclastogenesis. The number of released particles and their chemical composition and nanotopography had a significant effect on the inflammatory response. Sandblasted surfaces released the highest number of particles with the greatest nanoroughness properties. Particles from sandblasted/acid-etched discs induced a milder inflammatory response than those from sandblasted discs but a stronger inflammatory response than those from machined discs. Titanium particles were then embedded in fibrin membranes placed on mouse calvariae for 5 weeks. Using micro-CT, we observed that particles from sandblasted discs induced more osteolysis than those from sandblasted/acid-etched discs. In summary, ultrasonic scaling of titanium implants releases particles in a surface type-dependent manner and may aggravate peri-implantitis. Future studies should assess whether surface roughening affects the extent of released wear particles and aseptic loosening of orthopedic implants. PMID:28059080
MEAT SCIENCE AND MUSCLE BIOLOGY SYMPOSIUM--anabolic implants and meat quality.
Duckett, S K; Pratt, S L
2014-01-01
Anabolic implants are routinely used in the finishing phase of beef production to improve animal performance and feed efficiency. Implanting during the feedlot phase on average increases ADG 18%, feed intake 6%, feed efficiency 8%, carcass weight 5%, and ribeye area 4% compared with nonimplanted controls. Implants reduce the cost of beef production, which is important given current high feed costs and beef prices. In a 1996 review of 37 implant trials, the use of a combination (i.e., estrogenic and trenbolone acetate) implant increased returns by US$77/head compared with nonimplanted steers. If calculated using today's prices, a combination implant would increase returns by $163/head. However, concerns about potential negative effects of implants on marbling scores, quality grades, and tenderness exist. Changes in Warner-Bratzler shear force values of steaks from implanted steers are small (<0.5 kg) and appear related to an increase in initial tenderness, possibly due to hypertrophy of muscle fiber, instead of alterations in postmortem proteolysis. The increase in ribeye size observed with implanting may also reduce marbling scores through a dilution effect. The impact of anabolic implants on gene expression has shown that implanting downregulates expression of certain lipogenic genes (e.g., stearoyl-CoA desaturase, fatty acid synthetase, fatty acid elongase-6) in steers with low quality grades (Select-) but not in implanted steers with high quality grades (Choice-). Examination of the adipocyte's transcriptome has shown that 36 genes were differentially expressed due to implant treatment. More research is needed to further determine how anabolic implants alter lipogenic gene expression to address changes in marbling deposition with implant usage. Given our current high feed costs and cattle prices, anabolic implants are one of the most cost-effective technologies that can be used in beef production systems.
Yamaguchi, Yoko; Shiota, Makoto; FuJii, Masaki; Sekiya, Michi; Ozeki, Masahiko
2016-01-01
Primary stability after implant placement is essential for osseointegration. It is important to understand the bone/implant interface for analyzing the influence of implant design on primary stability. In this study rigid polyurethane foam is used as artificial bone to evaluate the bone-implant interface and to identify where the torque is being generated during placement. Five implant systems-Straumann-Standard (ST), Straumann-Bone Level (BL), Straumann-Tapered Effect (TE), Nobel Biocare-Brånemark MKIII (MK3), and Nobel Biocare-Brånemark MKIV (MK4)-were used for this experiment. Artificial bone blocks were prepared and the implant was installed. After placement, a metal jig and one side artificial bone block were removed and then the implant embedded in the artificial bone was exposed for observing the bone-implant interface. A digital micro-analyzer was used for observing the contact interface. The insertion torque values were 39.35, 23.78, 12.53, 26.35, and 17.79 N cm for MK4, BL, ST, TE, and MK3, respectively. In ST, MK3, TE, MK4, and BL the white layer areas were 61 × 103 μm(2), 37 × 103 μm(2), 103 × 103 μm(2) in the tapered portion and 84 × 03 μm(2) in the parallel portion, 134 × 103 μm(2), and 98 × 103 μm(2) in the tapered portion and 87 × 103 μm(2) in the parallel portion, respectively. The direct observation method of the implant/artificial bone interface is a simple and useful method that enables the identification of the area where implant retention occurs. A white layer at the site of stress concentration during implant placement was identified and the magnitude of the stress was quantitatively estimated. The site where the highest torque occurred was the area from the thread crest to the thread root and the under and lateral aspect of the platform. The artificial bone debris created by the self-tapping blade accumulated in both the cutting chamber and in the space between the threads and artificial bone.
Preparation and characterization of new biologically active polyurethane foams.
Savelyev, Yuri; Veselov, Vitali; Markovskaya, Ludmila; Savelyeva, Olga; Akhranovich, Elena; Galatenko, Natalya; Robota, Ludmila; Travinskaya, Tamara
2014-12-01
Biologically active polyurethane foams are the fast-developed alternative to many applications of biomedical materials. Due to the polyurethane structure features and foam technology it is possible to incorporate into their structure the biologically active compounds of target purpose via structural-chemical modification of macromolecule. A series of new biologically active polyurethane foams (PUFs) was synthesized with polyethers (MM 2500-5000), polyesters MM (500-2200), 2,4(2,6) toluene diisocyanate, water as a foaming agent, catalysts, foam stabilizers and functional compounds. Different functional compounds: 1,4-di-N-oxy-2,3-bis-(oxymethyl)-quinoxaline (DOMQ), partial sodium salt of poly(acrylic acid) and 2,6-dimethyl-N,N-diethyl aminoacetatanilide hydrochloride were incorporated into the polymer structure/composition due to the chemical and/or physical bonding. Structural peculiarities of PUFs were studied by FTIR spectroscopy and X-ray scattering. Self-adhesion properties of PUFs were estimated by measuring of tensile strength at break of adhesive junction. The optical microscopy method was performed for the PUF morphology studies. Toxicological estimation of the PUFs was carried out in vitro and in vivo. The antibacterial action towards the Gram-positive and Gram-negative bacteria (Escherichia coli ATC 25922, E. coli ATC 2150, Klebsiella pneumoniae 6447, Staphylococcus aureus 180, Pseudomonas aeruginosa 8180, Proteus mirabilis F 403, P. mirabilis 6054, and Proteus vulgaris 8718) was studied by the disc method on the solid nutrient. Physic-chemical properties of the PUFs (density, tensile strength and elongation at break, water absorption and vapor permeability) showed that all studied PUFs are within the operational requirements for such materials and represent fine-cellular foams. Spectral studies confirmed the incorporation of DOMQ into the PUF's macrochain. PUFs are characterized by microheterogeneous structure. They are antibacterially active, non-toxic materials with high affinity to the tissue body, self-adhesive properties and local anesthetic effect. Copyright © 2014 Elsevier B.V. All rights reserved.
Metzler, Philipp; von Wilmowsky, Cornelius; Stadlinger, Bernd; Zemann, Wolfgang; Schlegel, Karl Andreas; Rosiwal, Stephan; Rupprecht, Stephan
2013-09-01
Promising biomaterial characteristics of diamond-coatings in biomedicine have been described in the literature. However, there is a lack of knowledge about implant osseointegration of this surface modification compared to the currently used sandblasted acid-etched Ti-Al6-V4 implants. The aim of this study was to investigate the osseointegration of microwave plasma-chemical-vapour deposition (MWP-CVD) diamond-coated Ti-Al6-V4 dental implants after healing periods of 2 and 5 months. Twenty-four MWP-CVD diamond-coated and 24 un-coated dental titanium-alloy implants (Ankylos(®)) were placed in the frontal skull of eight adult domestic pigs. To evaluate the effects of the nano-structured surfaces on bone formation, a histomorphometric analysis was performed after 2 and 5 months of implant healing. Histomorphometry analysed the bone-to-implant contact (BIC). No significant difference in BIC for the diamond-coated implants in comparison to reference implants could be observed for both healing periods. Scanning electron microscopy revealed an adequate interface between the bone and the diamond surface. No delamination or particle-dissociation due to shearing forces could be detected. In this study, diamond-coated dental titanium-alloy implants and sandblasted acid-etched implants showed a comparable degree of osseointegration. Copyright © 2012 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Acetyl diacylglycerol produced by modified camelina (Camelina sativa)
USDA-ARS?s Scientific Manuscript database
Acetyl diacylglyceride (Acetyl-TAG) is a component of a commercial product, ACETEM, manufactured by transesterification reaction of triglycerides, glycerol, and triacetin or by acetylation of mono- and diglycerides with acetic acid anhydride. ACETEM is commonly used as foaming agents and coatings in...
Toxicokinetics of perfluorooctanoate (PFOA) in rainbow trout(Oncorhynchus mykiss)
Perfluoroalkyl acids (PFAAs) are widely used as stain resistant coatings for cloth, paper, and leather, and as surfactants, fire-fighting foams, and photographic developers. Individual PFAAs have been shown to accumulate in fish and wildlife; however, the extent of this accumulat...
Kulakov, A A; Volozhin, A I; Tkachenko, V M; Doktorov, A A; Salim, Ibrakhim Samir
2007-01-01
Influence of HAP-gel (2 g of 2% solution of hyaluronic acid mixed with 0,5 g of hydroxyapatite and 0,1 ml of colloidal silver) upon osseointegration in case of delayed introduction of titanium implantates in dog jaw. By scanning electron microscopy it was shown that solely use either of HAP-gel or of ceramic spraying increased direct contact area between bone and implantates in the 6 and 9 months time period. Combination of spray-coated ceramic with HAP-gel was effective in 3 months after implantation, when solely the HAP-gel or the ceramic spraying were little effective. In the following terms of experiment (6 and 9 months) significant differences between groups 3 and 4 (implantate with ceramic spraying but without HAP-gel in the alveolus and implantate with ceramic spraying and with HAP-gel in the alveolus) were not found. The area of implantate integration with jaw bone (cortical part of it was excluded) was equal to 80% and was maximal for the given conditions of the experiment.
Nanotubular topography enhances the bioactivity of titanium implants.
Huang, Jingyan; Zhang, Xinchun; Yan, Wangxiang; Chen, Zhipei; Shuai, Xintao; Wang, Anxun; Wang, Yan
2017-08-01
Surface modification on titanium implants plays an important role in promoting mesenchymal stem cell (MSC) response to enhance osseointegration persistently. In this study, nano-scale TiO 2 nanotube topography (TNT), micro-scale sand blasted-acid etched topography (SLA), and hybrid sand blasted-acid etched/nanotube topography (SLA/TNT) were fabricated on the surfaces of titanium implants. Although the initial cell adherence at 60 min among TNT, SLA and TNT/SLA was not different, SLA and SLA/TNT presented to be rougher and suppressed the proliferation of MSC. TNT showed hydrophilic surface and balanced promotion of cellular functions. After being implanted in rabbit femur models, TNT displayed the best osteogenesis inducing ability as well as strong bonding strength to the substrate. These results indicate that nano-scale TNT provides favorable surface topography for improving the clinical performance of endosseous implants compared with micro and hybrid micro/nano surfaces, suggesting a promising and reliable surface modification strategy of titanium implants for clinical application. Copyright © 2017 Elsevier Inc. All rights reserved.
Biswas, A; Mohan, J; Mandal, A B; Lal, N
2017-04-01
An attempt was made to investigate the effect of dietary selenium (Se) on physical and cloacal gland size, foam production, biochemical composition of foam and semen biochemical characteristics of male Japanese quail (Coturnix coturnix Japonica). Two hundred twenty-five (225)-day-old male Japanese quail were randomly distributed to three dietary treatment groups for a period of 20 weeks. Each treatment comprised of three replicates, each containing 25 chicks. Three experimental diets were supplemented with 0, 0.5 and 1.0 mg Se/kg (T 1 , T 2 and T 3, respectively), and diet T 1 was considered as control. Sodium selenite was used as the source of selenium. All the birds were provided with feed and water ad libitum. Cloacal foam characteristics, that is cloacal gland index and foam weight, were significantly higher in T 2 group. However, body weight, frequency of foam discharge and testes weight (left and right) did not differ significantly (p > 0.05). Physical characteristics of semen, that is semen volume and sperm concentration, did not differ (p > 0.05) among the Se-treated groups. The sperm motility, live-dead count and abnormality improved significantly (p < 0.05) in 0.5 mg/Se-supplemented group compared to 0 or 1.0 mg/Se-supplemented groups. Similarly, fertility and hatchability percentages were higher (p < 0.05) in 0.5 mg/Se-supplemented group than in control or 1.0 mg/Se-supplemented counterparts. The biochemical characteristics of foam in terms of total protein, acid phosphatase (ACP) and nitric oxide did not differ (p > 0.05), while the concentration of glucose was higher (p < 0.05) in 0.5 mg/Se-supplemented diet. On the other hand, alkaline phosphatase (ALP), alanine aminotransferase (ALT) and aspartate aminotransferase (AST) were lower (p < 0.05) in 0.5 mg/Se-supplemented group compared to control or 1.0 mg/Se-supplemented groups. From this study, it was concluded that supplementation of 0.5 mg Se/kg diet was beneficial for foam variables, biochemical composition of foam, semen characteristics and fertility in male Japanese quail. Journal of Animal Physiology and Animal Nutrition © 2016 Blackwell Verlag GmbH.
Cheng, Yicheng; Gao, Bo; Liu, Xianghui; Zhao, Xianghui; Sun, Weige; Ren, Huifang; Wu, Jiang
2016-01-01
To prevent peri-implant infection, a new antibacterial coating containing a halogenated furanone compound, (Z-)-4-bromo-5-(bromomethylene)-2(5H)-furanone-loaded poly(l-lactic acid) nanoparticles, has been fabricated. The current study was designed to evaluate the preventive effect of the antibacterial coating under a simulated environment of peri-implant infection in vivo. Microarc-oxidized titanium implants treated with minocycline hydrochloride ointment were used as positive control group, and microarc-oxidized titanium implants without any treatment were used as blank control group. Three kinds of implants were implanted in dogs' mandibles, and the peri-implant infection was simulated by silk ligation and feeding high sugar diet. After 2-month implantation, the results showed that no significant differences were detected between the experimental and positive control groups (P>0.05), but the data of clinical measurements of the blank control group were significantly higher than those of the other two groups (P<0.05), and the bone-implant contact rate and ultimate interfacial strength were significantly lower than those of the other two groups (P<0.05). Scanning electron microscope observation and histological examination showed that more new bone was formed on the surface of the experimental and positive control groups. It can be concluded that the antibacterial coating fabricated on implants has remarkable preventive effect on peri-implant infection at the early stage.
Taxt-Lamolle, Sébastien F; Rubert, Marina; Haugen, Håvard J; Lyngstadaas, Ståle Petter; Ellingsen, Jan Eirik; Monjo, Marta
2010-03-01
Previous studies have shown that bone-to-implant attachment of titanium implants to cortical bone is improved when the surface is modified with hydrofluoric acid. The aim of this study was to investigate if biological factors are involved in the improved retention of these implants. Fluoride was implemented in implant surfaces by cathodic reduction with increasing concentrations of HF in the electrolyte. The modified implants were placed in the cortical bone in the tibias of New Zealand white rabbits. After 4 weeks of healing, wound fluid collected from the implant site showed lower lactate dehydrogenase activity and less bleeding in fluoride-modified implants compared to control. A significant increase in gene expression levels of osteocalcin and tartrate-resistant acid phosphatase (TRAP) was found in the cortical bone attached to Ti implants modified with 0.001 and 0.01 vol.% HF, while Ti implants modified with 0.1% HF showed only induced TRAP mRNA levels. These results were supported by the performed micro-CT analyses. The volumetric bone mineral density of the cortical bone hosting Ti implants modified with 0.001% and 0.01% HF was higher both in the newly woven bone (<100 microm from the interface) and in the older Haversian bone (>100 microm). In conclusion, the modulation of these biological factors by surface modification of titanium implants with low concentrations of HF using cathodic reduction may explain their improved osseointegration properties. Copyright 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Simple additive manufacturing of an osteoconductive ceramic using suspension melt extrusion.
Slots, Casper; Jensen, Martin Bonde; Ditzel, Nicholas; Hedegaard, Martin A B; Borg, Søren Wiatr; Albrektsen, Ole; Thygesen, Torben; Kassem, Moustapha; Andersen, Morten Østergaard
2017-02-01
Craniofacial bone trauma is a leading reason for surgery at most hospitals. Large pieces of destroyed or resected bone are often replaced with non-resorbable and stock implants, and these are associated with a variety of problems. This paper explores the use of a novel fatty acid/calcium phosphate suspension melt for simple additive manufacturing of ceramic tricalcium phosphate implants. A wide variety of non-aqueous liquids were tested to determine the formulation of a storable 3D printable tricalcium phosphate suspension ink, and only fatty acid-based inks were found to work. A heated stearic acid-tricalcium phosphate suspension melt was then 3D printed, carbonized and sintered, yielding implants with controllable macroporosities. Their microstructure, compressive strength and chemical purity were analyzed with electron microscopy, mechanical testing and Raman spectroscopy, respectively. Mesenchymal stem cell culture was used to assess their osteoconductivity as defined by collagen deposition, alkaline phosphatase secretion and de-novo mineralization. After a rapid sintering process, the implants retained their pre-sintering shape with open pores. They possessed clinically relevant mechanical strength and were chemically pure. They supported adhesion of mesenchymal stem cells, and these were able to deposit collagen onto the implants, secrete alkaline phosphatase and further mineralize the ceramic. The tricalcium phosphate/fatty acid ink described here and its 3D printing may be sufficiently simple and effective to enable rapid, on-demand and in-hospital fabrication of individualized ceramic implants that allow clinicians to use them for treatment of bone trauma. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Kim, Dae-Seung; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin
2014-06-01
We compared implant stability as determined by the peak frequency from the impact response with the implant stability quotient (ISQ) by resonance frequency analysis (RFA) in various artificial bone conditions. The clinical bone conditions were simulated using an artificial bone material with different cortical thicknesses and trabecular densities. The artificial bone material was solid, rigid polyurethane. The polyurethane foam of 0.8g/cm(3) density was used for the cortical bone layer, and that of 0.08, 0.16, 0.24, 0.32, and 0.48g/cm(3) densities for the trabecular bone layer. The cortical bone material of 4 different thicknesses (1.4, 1.6, 1.8, and 2.0mm) was attached to the trabecular bone with varying density. Two types of dental implants (10 and 13mm lengths of 4.0mm diameter) were placed into the artificial bone blocks. An inductive sensor was used to measure the vibration caused by tapping the adapter-implant assembly. The peak frequency of the power spectrum of the impact response was used as the criterion for implant stability. The ISQ value was also measured for the same conditions. The stability, as measured by peak frequency (SPF) and ISQ value, increased as the trabecular density and the cortical density increased in linear regression analysis. The SPF and ISQ values were highly correlated with each other when the trabecular bone density and cortical bone thickness changed (Pearson correlation=0.90, p<0.01). The linear regression of the SPF with the cortical bone thickness showed higher goodness of fit (R(2) measure) than the ISQ value with the cortical bone thickness. The SPF could differentiate implantation conditions as many as the ISQ value when the trabecular bone density and the cortical density changed. However, the ISQ value was not consistent with the general stability tendency in some conditions. The SPF showed better consistency and differentiability with implant stability than the ISQ value by resonance frequency analysis in the various implantation conditions. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.
High-Potential Metalless Nanocarbon Foam Supercapacitors Operating in Aqueous Electrolyte.
Liu, Chueh; Li, Changling; Ahmed, Kazi; Mutlu, Zafer; Lee, Ilkeun; Zaera, Francisco; Ozkan, Cengiz S; Ozkan, Mihrimah
2018-04-01
Light-weight graphite foam decorated with carbon nanotubes (dia. 20-50 nm) is utilized as an effective electrode without binders, conductive additives, or metallic current collectors for supercapacitors in aqueous electrolyte. Facile nitric acid treatment renders wide operating potentials, high specific capacitances and energy densities, and long lifespan over 10 000 cycles manifested as 164.5 and 111.8 F g -1 , 22.85 and 12.58 Wh kg -1 , 74.6% and 95.6% capacitance retention for 2 and 1.8 V, respectively. Overcharge protection is demonstrated by repetitive cycling between 2 and 2.5 V for 2000 cycles without catastrophic structural demolition or severe capacity fading. Graphite foam without metallic strut possessing low density (≈0.4-0.45 g cm -3 ) further reduces the total weight of the electrode. The thorough investigation of the specific capacitances and coulombic efficiencies versus potential windows and current densities provides insights into the selection of operation conditions for future practical devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Polymer microcapsules with "foamed" membranes.
Lavergne, Fleur-Marie; Cot, Didier; Ganachaud, François
2007-06-05
This article describes the preparation of capsules displaying craters at their surfaces and independent holes inside their membranes. These poly(methylmethacrylate) capsules of 20 to 200 microm diameter are prepared by a solvent evaporation process and typically contain a dispersant, polyvinyl alcohol, and an excipient, namely, a fatty acid triglyceride (miglyol 812). Spectroscopic methods showed that, depending on the miglyol content, the craters at the surface exhibited sizes of about 1 to 2 microm, whereas the core structure of the membrane changed significantly, typically from "soft-part-of-bread" up to "foamed"-like aspects. Among several spectroscopy techniques, confocal fluorescence microscopy confirmed that the capsules retained the miglyol in their core and not in the craters or holes, even after centrifugation and handling. This technique also showed that holes in the membrane are filled with water. A possible analysis of the "foaming" phenomenon based on the surface tensions of different oils, as well as their optimal hydrophile-lipophile balance (HLBO), is added to generalize the concept.
Weinberger, R; Mann, B; Posluszny, J
1980-04-01
A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.
Rafe, Ali; Sadeghian, Alireza; Hoseini-Yazdi, Seyedeh Zohreh
2017-05-01
Extrusion is a multistep thermal process which has been utilized in a wide spectrum of food preparations. The effect of extrusion processing on the physicochemical, nutritional, and functional properties of Tarom cultivar rice bran was studied. However, the color of rice bran was improved by extrusion processing, but the protein content was reduced in the stabilized rice bran, which can be related to the denaturation of protein. Extrusion had also a reduction significant effect on the phytic acid as well as vitamin E in rice bran. However, the content of niacin, riboflavin, pantothenic acid, and folic acid remained unchanged, but the dietary fiber was enhanced which has beneficial health effect on human consumption. In comparison with unstabilized rice bran, water holding capacity was enhanced, but the oil absorption capacity was reduced. Foaming capacity and foaming stability of extruded rice bran was more than that of untreated rice bran, although they were less than that of rice bran protein concentrate/isolate. In general, the extrusion process improves some functional and nutritional properties of rice bran which are valuable to industrial applications and have potential as ingredient in food to improve consumer health.
Moawed, E A; Radwan, A M
2017-02-15
The commercial polyurethane foam was acid modified to get an inexpensive adsorbent (AM-PUF) has highly surface polarity and sorption capacity. The elemental analysis, scanning electron microscopy, thermal analysis, ultraviolet/visible/infrared spectroscopies and X-ray diffraction were used for characterization of AM-PUF. The surface of AM-PUF has amorphous character (broadband at 2θ, 21.75°) and contains several active sites e.g. NH, OH, CO, CC and COC groups. The electrical conductivity (σ), iodine value and methylene blue index of AM-PUF are 1.7×10 -5 Ω -1 m -1 , 208mg/g and 107mg/g. The AM-PUF has a high efficiency for completely removing (99-100%) of Aldrin, DDT, Endrin, Heptachlor, Heptachlor epoxide and Lindane pesticides in both acidic and alkaline solutions. The removing rates of the organochlorine pesticides from wastewater are very rapid (t 1/2 =22s). The negative value of ΔG (-10.9kJ/mol) for removing of OCPs using AM-PUF showed that the feasibility of the removing process and its spontaneous nature. Copyright © 2017 Elsevier B.V. All rights reserved.
2017-01-01
Purpose The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque. PMID:28462009
Polyfluoroalkyl Substances ( PFAS ), like perfluorooctanoic acid, have been used for the last 50 years in a wide variety of industrial processes and...The Department of Defense (DoD) has used PFAS -based Aqueous Film Forming Foam (AFFF) at fire training facilities and aircraft hangars. These AFFFs have...contaminated approximately 600 sites classified as fire training facilities with PFAS (Huang, 2013). This study focused on testing the most likely
Gollwitzer, Hans; Ibrahim, Karim; Meyer, Henriette; Mittelmeier, Wolfram; Busch, Raymonde; Stemberger, Axel
2003-03-01
Biomaterial-associated bacterial infections present common and challenging complications with medical implants. The purpose of this study was to determine the antibacterial properties of a low molecular weight biodegradable poly(D,L-lactic acid) coating with integrated antibiotics gentamicin and teicoplanin. Coating of Kirschner-wires was carried out by a solvent casting technique under aseptic conditions with and without incorporated antibiotics. Release kinetics of gentamicin and teicoplanin were studied in phosphate-buffered saline. Initial bacterial adhesion of Staphylococcus epidermidis on coated and bare implants was determined by radiolabelling and counts of detached viable organisms. The incorporated antibiotics showed a continuous release over a period of at least 96 h with an initial peak of release in the first 6 h. Attachment of non-viable microorganisms, detected by radiolabelled bacteria, was increased significantly by the polymer coatings (P < 0.05). In contrast, the number of viable bacteria was reduced by the pure polymer (P < 0.01) and further by the polymer-antibiotic combinations (P < 0.05). Poly(D,L-lactic acid) coating of implants could offer new perspectives in preventing biomaterial-associated infections. Combinations with other drugs to formulate custom-tailored implant surfaces are feasible.
Szmukler-Moncler, S; Bischof, M; Nedir, R; Ermrich, M
2010-09-01
Acid etching is a popular method to texture the surface of dental implants. During etching, the titanium oxide protective layer is dissolved and small native hydrogen ions diffuse into the unprotected implant surface. They enrich the implant surface with hydrogen and precipitate into titanium hydride (TiH). The aim of this study was to measure the concentration of TiH at the implant surface and the total concentration of Hydrogen at five commercially available implant systems, made of either commercially pure (cp) titanium or titanium alloy. X-Ray diffraction (XRD) was conducted on each implant system to determine the compounds present at the implant surface. Following a TiH(2)/Ti calibration curve, the concentration of TiH was determined. Concentration of hydrogen in the implants was measured by the inert gas fusion thermal conductivity/infrared detection method. XRD data showed that TiH was present on all cp titanium implants but not on the alloyed implants. TiH concentration varied between 5% and 37%. Hydrogen concentration varied between 43 and 108 ppm, no difference in uptake was found between the cp titanium and alloyed implants. Low solubility of hydrogen in alpha-titanium is responsible for precipitation into TiH. Stronger etching conditions led to higher concentration of TiH2-x. High solubility of hydrogen in the beta-phase of the alloy is preventing hydrogen from precipitating into TiH. All implants, even those lacking TiH at the surface, were enriched with hydrogen. In all implants, hydrogen concentration was within the normative limit of 130 ppm.
DWPF Recycle Evaporator Simulant Tests
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M
2005-04-05
Testing was performed to determine the feasibility and processing characteristics of an evaporation process to reduce the volume of the recycle stream from the Defense Waste Processing Facility (DWPF). The concentrated recycle would be returned to DWPF while the overhead condensate would be transferred to the Effluent Treatment Plant. Various blends of evaporator feed were tested using simulants developed from characterization of actual recycle streams from DWPF and input from DWPF-Engineering. The simulated feed was evaporated in laboratory scale apparatus to target a 30X volume reduction. Condensate and concentrate samples from each run were analyzed and the process characteristics (foaming,more » scaling, etc) were visually monitored during each run. The following conclusions were made from the testing: Concentration of the ''typical'' recycle stream in DWPF by 30X was feasible. The addition of DWTT recycle streams to the typical recycle stream raises the solids content of the evaporator feed considerably and lowers the amount of concentration that can be achieved. Foaming was noted during all evaporation tests and must be addressed prior to operation of the full-scale evaporator. Tests were conducted that identified Dow Corning 2210 as an antifoam candidate that warrants further evaluation. The condensate has the potential to exceed the ETP WAC for mercury, silicon, and TOC. Controlling the amount of equipment decontamination recycle in the evaporator blend would help meet the TOC limits. The evaporator condensate will be saturated with mercury and elemental mercury will collect in the evaporator condensate collection vessel. No scaling on heating surfaces was noted during the tests, but splatter onto the walls of the evaporation vessels led to a buildup of solids. These solids were difficult to remove with 2M nitric acid. Precipitation of solids was not noted during the testing. Some of the aluminum present in the recycle streams was converted from gibbsite to aluminum oxide during the evaporation process. The following recommendations were made: Recycle from the DWTT should be metered in slowly to the ''typical'' recycle streams to avoid spikes in solids content to allow consistent processing and avoid process upsets. Additional studies should be conducted to determine acceptable volume ratios for the HEME dissolution and decontamination solutions in the evaporator feed. Dow Corning 2210 antifoam should be evaluated for use to control foaming. Additional tests are required to determine the concentration of antifoam required to prevent foaming during startup, the frequency of antifoam additions required to control foaming during steady state processing, and the ability of the antifoam to control foam over a range of potential feed compositions. This evaluation should also include evaluation of the degradation of the antifoam and impact on the silicon and TOC content of the condensate. The caustic HEME dissolution recycle stream should be neutralized to at least pH of 7 prior to blending with the acidic recycle streams. Dow Corning 2210 should be used during the evaporation testing using the radioactive recycle samples received from DWPF. Evaluation of additional antifoam candidates should be conducted as a backup for Dow Corning 2210. A camera and/or foam detection instrument should be included in the evaporator design to allow monitoring of the foaming behavior during operation. The potential for foam formation and high solids content should be considered during the design of the evaporator vessel.« less
Chmielowski, Rebecca A; Abdelhamid, Dalia S; Faig, Jonathan J; Petersen, Latrisha K; Gardner, Carol R; Uhrich, Kathryn E; Joseph, Laurie B; Moghe, Prabhas V
2017-07-15
Enhanced bioactive anti-oxidant formulations are critical for treatment of inflammatory diseases, such as atherosclerosis. A hallmark of early atherosclerosis is the uptake of oxidized low density lipoprotein (oxLDL) by macrophages, which results in foam cell and plaque formation in the arterial wall. The hypolipidemic, anti-inflammatory, and antioxidative properties of polyphenol compounds make them attractive targets for treatment of atherosclerosis. However, high concentrations of antioxidants can reverse their anti-atheroprotective properties and cause oxidative stress within the artery. Here, we designed a new class of nanoparticles with anti-oxidant polymer cores and shells comprised of scavenger receptor targeting amphiphilic macromolecules (AMs). Specifically, we designed ferulic acid-based poly(anhydride-ester) nanoparticles to counteract the uptake of high levels of oxLDL and regulate reactive oxygen species generation (ROS) in human monocyte derived macrophages (HMDMs). Compared to all compositions examined, nanoparticles with core ferulic acid-based polymers linked by diglycolic acid (PFAG) showed the greatest inhibition of oxLDL uptake. At high oxLDL concentrations, the ferulic acid diacids and polymer nanoparticles displayed similar oxLDL uptake. Treatment with the PFAG nanoparticles downregulated the expression of macrophage scavenger receptors, CD-36, MSR-1, and LOX-1 by about 20-50%, one of the causal factors for the decrease in oxLDL uptake. The PFAG nanoparticle lowered ROS production by HMDMs, which is important for maintaining macrophage growth and prevention of apoptosis. Based on these results, we propose that ferulic acid-based poly(anhydride ester) nanoparticles may offer an integrative strategy for the localized passivation of the early stages of the atheroinflammatory cascade in cardiovascular disease. Future development of anti-oxidant formulations for atherosclerosis applications is essential to deliver an efficacious dose while limiting localized concentrations of pro-oxidants. In this study, we illustrate the potential of degradable ferulic acid-based polymer nanoparticles to control macrophage foam cell formation by significantly reducing oxLDL uptake through downregulation of scavenger receptors, CD-36, MSR-1, and LOX-1. Another critical finding is the ability of the degradable ferulate-based polymer nanoparticles to lower macrophage reactive oxygen species (ROS) levels, a precursor to apoptosis and plaque escalation. The degradable ferulic acid-based polymer nanoparticles hold significant promise as a means to alter the treatment and progression of atherosclerosis. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Jian, Hong-lei; Liao, Xiao-xia; Zhu, Li-wei; Zhang, Wei-ming; Jiang, Jian-xin
2011-07-15
A biosurfactant, named tea saponin (TS), was isolated and purified from the defatted seed of Camellia oleifera Abel. The characterization of TS including molecular weight, glycosyl composition, and thermal behavior as well as the surface and foaming properties was conducted. The synergistic interactions of binary systems of CTAB-TS, SDS-TS, and Brij35-TS were investigated. The results show that TS had a weight-average molecular weight of 809.12 g mol(-1) and contained four aglycones of L-rhamnose, D-galactose, D-glucose, and D-glucuronic acid. The critical micelle concentration (cmc) of 2.242 mmol L(-1) and the minimum surface tension (γ(cmc)) of 43.5 mN m(-1) were determined for TS. Synergisms in surface tension reduction efficiency, in mixed micelle formation, and in surface tension reduction effectiveness were observed in CTAB-TS and SDS-TS systems, whereas that was not shown in Brij35-TS mixtures. The mixtures of TS with CTAB and SDS showed synergism in foaming efficiency, but this synergism did not exist in Brij35-TS system with respect to the surface properties. Nevertheless, there appears to be no significant correlation between foam stability and the surface properties. Copyright © 2011 Elsevier Inc. All rights reserved.
Mechanisms of foam cell formation in atherosclerosis.
Chistiakov, Dimitry A; Melnichenko, Alexandra A; Myasoedova, Veronika A; Grechko, Andrey V; Orekhov, Alexander N
2017-11-01
Low-density lipoprotein (LDL) and cholesterol homeostasis in the peripheral blood is maintained by specialized cells, such as macrophages. Macrophages express a variety of scavenger receptors (SR) that interact with lipoproteins, including SR-A1, CD36, and lectin-like oxLDL receptor-1 (LOX-1). These cells also have several cholesterol transporters, including ATP-binding cassette transporter ABCA1, ABCG1, and SR-BI, that are involved in reverse cholesterol transport. Lipids internalized by phagocytosis are transported to late endosomes/lysosomes, where lysosomal acid lipase (LAL) digests cholesteryl esters releasing free cholesterol. Free cholesterol in turn is processed by acetyl-CoA acetyltransferase (ACAT1), an enzyme that transforms cholesterol to cholesteryl esters. The endoplasmic reticulum serves as a depot for maintaining newly synthesized cholesteryl esters that can be processed by neutral cholesterol ester hydrolase (NCEH), which generates free cholesterol that can exit via cholesterol transporters. In atherosclerosis, pro-inflammatory stimuli upregulate expression of scavenger receptors, especially LOX-1, and downregulate expression of cholesterol transporters. ACAT1 is also increased, while NCEH expression is reduced. This results in deposition of free and esterified cholesterol in macrophages and generation of foam cells. Moreover, other cell types, such as endothelial (ECs) and vascular smooth muscle cells (VSMCs), can also become foam cells. In this review, we discuss known pathways of foam cell formation in atherosclerosis.
Todeschi, Maria R; El Backly, Rania M; Varghese, Oommen P; Hilborn, Jöns; Cancedda, Ranieri; Mastrogiacomo, Maddalena
2017-07-01
This study aimed to identify host cell recruitment patterns in a mouse model in response to rhBMP-2 releasing hyaluronic acid hydrogels and influence of added nano-hydroxyapatite particles on rhBMP-2 release and pattern of bone formation. Implanted gels were retrieved after implantation and cells were enzymatically dissociated for flow cytometric analysis. Percentages of macrophages, progenitor endothelial cells and putative mesenchymal stem cells were measured. Implants were evaluated for BMP-2 release by ELISA and by histology to monitor tissue formation. Hyaluronic acid+BMP-2 gels influenced the inflammatory response in the bone healing microenvironment. Host-derived putative mesenchymal stem cells were major contributors. Addition of hydroxyapatite nanoparticles modified the release pattern of rhBMP-2, resulting in enhanced bone formation.
Selvaraj, Subbalaxmi; Vytla, Ramachandra Murty
2017-10-01
Production of tannase from B. gottheilii M2S2 was studied under solid-state fermentation with an optimized medium consisting of polyurethane foam matrix of dimension 40 × 40 × 5 mm, impregnated with a liquid medium comprising (w/v): 4% tannic acid; 2% NH 4 NO 3 ; 0.1% KH 2 PO 4 ; 0.2% MgSO 4 ; 0.1% NaCl and 0.05% CaCl 2 ·2H 2 O in distilled water, having a pH of 4.7. Maximum tannase production of 56.87 U/L was obtained after 32 h of fermentation at 32 °C in static condition. This study deals with the evaluation of unstructured kinetic models to understand the behavior of biomass, tannase production and tannic acid degradation, with the fermentation time. The growth rate of B. gottheilii M2S2 was 0.0703 h -1 at 32 h of fermentation. Product ( Y x/s ) and biomass yield ( Y p/s ) coefficients were estimated as 1.77 U/g of tannic acid and 0.276 g of biomass/g of tannic acid. All the kinetic constants µ , α , β , m and n were evaluated using MATLAB 2015Rb program. The experimental and model-generated data showed a good correlation, which indicated that these models will describe tannase production and fermentation process.
Ong, Kevin L; Rundell, Steve; Liepins, Imants; Laurent, Ryan; Markel, David; Kurtz, Steven M
2009-11-01
Press-fit implantation may result in acetabular component deformation between the ischial-ilial columns ("pinching"). The biomechanical and clinical consequences of liner pinching due to press-fit implantation have not been well studied. We compared the effects of pinching on the polyethylene fracture risk, potential wear rate, and stresses for two different thickness liners using computational methods. Line-to-line ("no pinch") reaming and 2 mm underreaming press fit ("pinch") conditions were examined for Trident cups with X3 polyethylene liner wall thicknesses of 5.9 mm (36E) and 3.8 mm (40E). Press-fit cup deformations were measured from a foam block configuration. A hybrid material model, calibrated to experimentally determined stress-strain behavior of sequentially annealed polyethylene, was applied to the computational model. Molecular chain stretch did not exceed the fracture threshold in any cases. Nominal shell pinch of 0.28 mm was estimated to increase the volumetric wear rate by 70% for both cups and peak contact stresses by 140 and 170% for the 5.9 and 3.8 mm-thick liners, respectively. Although pinching increases liner stresses, polyethylene fracture is highly unlikely, and the volumetric wear rates are likely to be low compared to conventional polyethylene. (c) 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Zheng, Luo Luo; Vanchinathan, Vijay; Dalal, Roopa; Noolandi, Jaan; Waters, Dale J.; Hartmann, Laura; Cochran, Jennifer R.; Frank, Curtis W.; Yu, Charles Q.; Ta, Christopher N.
2015-01-01
We evaluated the biocompatibility of a poly(ethylene glycol) and poly(acrylic acid) (PEG/PAA) interpenetrating network hydrogel designed for artificial cornea in a rabbit model. PEG/PAA hydrogel measuring 6 mm in diameter was implanted in the corneal stroma of twelve rabbits. Stromal flaps were created with a microkeratome. Randomly, six rabbits were assigned to bear the implant for 2 months, two rabbits for 6 months, two rabbits for 9 months, one rabbit for 12 months, and one rabbit for 16 months. Rabbits were evaluated monthly. After the assigned period, eyes were enucleated, and corneas were processed for histology and immunohistochemistry. There were clear corneas in three of six rabbits that had implantation of hydrogel for 2 months. In the six rabbits with implant for 6 months or longer, the corneas remained clear in four. There was a high rate of epithelial defect and corneal thinning in these six rabbits. One planned 9-month rabbit developed extrusion of implant at 4 months. The cornea remained clear in the 16-month rabbit but histology revealed epithelial in-growth. Intrastromal implantation of PEG/PAA resulted in a high rate of long-term complications. PMID:25778285
NASA Astrophysics Data System (ADS)
Kormin, Shaharuddin; Rus, Anika Zafiah M.; Azahari, M. Shafiq M.
2017-08-01
Liquefied oil palm mesocarp fibre (LOPMF) is a promising natural material that can be used as biopolyol of polyurethane foam. The aim of this study was to utilizing solvolysis liquefaction conversion technology of oil palm mesocarp fibre (OPMF) for polyurethane (PU) foam. LOPMF was obtained with liquefaction of fibre in polyhydric alchohol (PA) such as ethylene glycol (EG), polyethylene glycol (PEG) and glycerol (GLY) as liquefaction solvent and sulphuric acid (H2SO4) in three different OPMF/PA ratio (1/2, 1/3 and 1/4) in conventional glass reactor. During the liquefaction, cellulose, semi-cellulose and lignin are decomposed, which results in changes of acid value and hydroxyl value. Liquefied OPMF and residues were characterized by Fourier transform infrared (FT-IR) spectroscopy. The results revealed that almost 50% of the OPMF converted into biopolyol product within 2 hours with OPMF/PA ratio of 1/4. Biopolyol produced under different condition showed viscosities from 210 to 450 Pa.s. The hydroxyl and acid values of the liquefied OPMF varied with the liquefied conditions. It was observed that with an increase in the liquefaction solvent (PA) amount in the mixture resulted in a high acid value and hydroxyl value for the OPMF. High reaction temperature combining with low OPMF material to solvent ratio resulted low hydroxyl number of LOPMF. The result in this study showed that biopolyol was suitable monomer for polyurethane synthesis.
Ghani, Milad; Frizzarin, Rejane M; Maya, Fernando; Cerdà, Víctor
2016-07-01
Herein we report the use of cobalt porous coordination polymers (PCP) as intermediates to prepare advanced extraction media based on layered double hydroxides (LDH) supported on melamine polymer foam. The obtained dissolvable Ni-Co LDH composite sponges can be molded and used as sorbent for the in-syringe solid-phase extraction (SPE) of phenolic acids from fruit juices. The proposed sorbent is obtained due to the surfactant-assisted self-assembly of Co(II)/imidazolate PCPs on commercially available melamine foam, followed by the in situ conversion of the PCP into the final dissolvable LDH coating. Advantageous features for SPE are obtained by using PCPs with hierarchical porosity (HPCPs). The LDH-sponge prepared using intermediate HPCPs (HLDH-sponge) is placed in the headspace of a glass syringe, enabling flow-through extraction followed by analyte elution by the dissolution of the LDH coating in acidic conditions. Three phenolic acids (gallic acid, p-hydroxybenzoic acid and caffeic acid) were extracted and quantified using high performance liquid chromatography. Using a 5mL sample volume, the obtained detection limits were 0.15-0.35μgL(-1). The proposed method for the preparation of HLDH-sponges showed a good reproducibility as observed from the intra- and inter-day RSD's, which were <10% for all analytes. The batch-to-batch reproducibility for three different batches of HLDH-sponges was 10.6-11.2%. Enrichment factors of 15-21 were obtained. The HLDH-sponges were applied satisfactorily to the determination of phenolic acids in natural and commercial fruit juices, obtaining relative recoveries among 89.7-95.3%. Copyright © 2016 Elsevier B.V. All rights reserved.
Ion implantation of highly corrosive electrolyte battery components
Muller, R.H.; Zhang, S.
1997-01-14
A method of producing corrosion resistant electrodes and other surfaces in corrosive batteries using ion implantation is described. Solid electrically conductive material is used as the ion implantation source. Battery electrode grids, especially anode grids, can be produced with greatly increased corrosion resistance for use in lead acid, molten salt, and sodium sulfur. 6 figs.
Ion implantation of highly corrosive electrolyte battery components
Muller, Rolf H.; Zhang, Shengtao
1997-01-01
A method of producing corrosion resistant electrodes and other surfaces in corrosive batteries using ion implantation is described. Solid electrically conductive material is used as the ion implantation source. Battery electrode grids, especially anode grids, can be produced with greatly increased corrosion resistance for use in lead acid, molten salt, end sodium sulfur.
Coelho, Paulo G; Cardaropoli, Giuseppe; Suzuki, Marcelo; Lemons, Jack E
2009-02-01
Thick bioceramic coatings like plasma sprayed hydroxyapatite have been shown to increase the overall tissue response and biomechanical fixation of dental implants. However, the presence and potential fracture of a bone-coating-metallic substrate interface at long times after implantation led these implants to fall from favor in clinical practice. The purpose of this study was to evaluate the biomechanical fixation and biological response of Ca- and P-based, 20-50 nm thickness bioceramic deposition on a previously alumina-blasted/acid-etched Ti-6Al-4V implant surface in a dog model. Cylindrical alumina-blasted/acid-etched (AB/AE) (Control, n = 16), and Nanothickness bioceramic coated AB/AE(Nano, n = 16) implant surfaces were surgically placed in dogs proximal tibia and remained for 2 and 4 weeks in vivo. Following euthanization, the implants-in-bone were mounted in epoxy and pullout at a 0.5 mm/min rate. Following mechanical testing, the specimens were decalcified and processed (Hematoxylin and Eosin) for standard transmitted light microscopy evaluation. Percent bone-to-implant contact (BIC) to the pulled out implant surface was determined through computer software. Statistical analyses were performed by one-way ANOVA at 95% level of significance and Tukey's post-hoc multiple comparisons. No significant differences in pullout force were observed (p > 0.88): 2W Control (212.08 +/- 42.96 N), 2W Nano (224.35 +/- 42.97 N), 4W Control (207.07 +/- 42.97 N), and 4W Nano (190.15 +/- 45.94 N). No significant differences in %BIC were observed (p > 0.94): 2W Control (72.66 +/- 8.51), 2W Nano (69.44 +/- 8.51), 4W Control (70.44 +/- 8.51), and 4W Nano (69.11 +/- 9.09). It is shown that 20-50 nm thickness bioceramic depositions onto previously alumina-blasted/acid-etched substrates did not improve the biomechanical fixation and the BIC at early implantation times, and studies concerning shorter and longer implantation times are recommended for confirmation or before a conclusion can be made. Copyright 2008 Wiley Periodicals, Inc.
Isocyanate emissions from pyrolysis of mattresses containing polyurethane foam.
Garrido, María A; Gerecke, Andreas C; Heeb, Norbert; Font, Rafael; Conesa, Juan A
2017-02-01
This study examined the emissions of powerful asthmatic agents called isocyanates from small-scale pyrolysis experiments of two common foams employed in mattress production such as flexible polyurethane foam (FPUF) and viscoelastic memory foam (VMF). A nitrogen atmosphere and five different temperatures, 300, 350, 400, 450 and 850 °C, were selected to carry out the experiments in order to evaluate the worst possible conditions for thermal degradation. A similar trend for both materials was found. At lower temperatures, diisocyanates were the most important products whereas at 850 °C monoisocyanates, and mainly isocyanic acid released mainly from the thermal cracking of diisocyanates evolved directly from the polymer chains. The total yields of isocyanates were in the range of 1.43-11.95 mg/m 3 for FPUF at 300-850 °C and 0.05-6.13 mg/m 3 for VMF, 300-850 °C. This difference could be a consequence of the lower amount of isocyanates employed in the VMF production which was confirmed by the nitrogen content of the foams, 5.95% FPUF vs. 3.34% in VMF. Additionally, a qualitative search for so far unknown isocyanates was performed in samples from the pyrolysis of FPUF at 300, 400 and 850 °C. It was confirmed that six different aminoisocyanates at 300 °C were evolved, whereas at 400 and 850 °C only five of them were detected. The general trend observed was a decrease of the aminoisocyanate levels with increasing pyrolysis temperature. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhou, Wei; Ding, Yani; Gao, Jihui; Kou, Kaikai; Wang, Yan; Meng, Xiaoxiao; Wu, Shaohua; Qin, Yukun
2018-02-01
The performance of cathode on H 2 O 2 electrogeneration is a critical factor that limits the practical application of electro-Fenton (EF) process. Herein, we report a simple but effective electrochemical modification of reticulated vitreous carbon foam (RVC foam) electrode for enhanced H 2 O 2 electrogeneration. Cyclic voltammetry, chronoamperometry, and X-ray photoelectron spectrum were used to characterize the modified electrode. Oxygen-containing groups (72.5-184.0 μmol/g) were introduced to RVC foam surface, thus resulting in a 59.8-258.2% higher H 2 O 2 yield. The modified electrodes showed much higher electrocatalytic activity toward O 2 reduction and good stability. Moreover, aimed at weakening the extent of electroreduction of H 2 O 2 in porous RVC foam, the strategy of pulsed current was proposed. H 2 O 2 concentration was 582.3 and 114.0% higher than the unmodified and modified electrodes, respectively. To test the feasibility of modification, as well as pulsed current, EF process was operated for removal of Reactive Blue 19 (RB19). The fluorescence intensity of hydroxybenzoic acid in EF with modified electrode is 3.2 times higher than EF with unmodified electrode, illustrating more hydroxyl radicals were generated. The removal efficiency of RB 19 in EF with unmodified electrode, modified electrode, and unmodified electrode assisted by pulsed current was 53.9, 68.9, and 81.1%, respectively, demonstrating that the green modification approach, as well as pulsed current, is applicable in EF system for pollutant removal. Graphical abstract ᅟ.
46 CFR 34.50-5 - Classification-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Classification-TB/ALL. 34.50-5 Section 34.50-5 Shipping... Semiportable Extinguishers § 34.50-5 Classification—TB/ALL. (a) Portable and semiportable extinguishers shall...-5(c) Classification type (Size) Soda-acid and water (Gallons) Foam (Gallons) Carbon dioxide (Pounds...
46 CFR 34.50-5 - Classification-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Classification-TB/ALL. 34.50-5 Section 34.50-5 Shipping... Semiportable Extinguishers § 34.50-5 Classification—TB/ALL. (a) Portable and semiportable extinguishers shall...-5(c) Classification type (Size) Soda-acid and water (Gallons) Foam (Gallons) Carbon dioxide (Pounds...
46 CFR 34.50-5 - Classification-TB/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Classification-TB/ALL. 34.50-5 Section 34.50-5 Shipping... Semiportable Extinguishers § 34.50-5 Classification—TB/ALL. (a) Portable and semiportable extinguishers shall...-5(c) Classification type (Size) Soda-acid and water (Gallons) Foam (Gallons) Carbon dioxide (Pounds...
Dundar, Serkan; Yaman, Ferhan; Gecor, Orhan; Cakmak, Omer; Kirtay, Mustafa; Yildirim, Tuba Talo; Karaman, Tahir; Benlidayi, Mehmet Emre
2017-06-01
The aim of this study was to evaluate the effects of local and systemic zoledronic acid (ZA) applications on titaniumoksit ceramic blasted (TiO-CB)- and sandblasted large acid-grit (SLA)-surfaced titanium implant osseointegration. Twelve New Zealand White rabbits were used in the study, divided into 6 groups: the TiO-CB (TiO-CB-CNT) (n = 2) and SLA (SLA-CNT) (n = 2) control groups in which TiO-CB- and SLA-surfaced titanium implants were surgically inserted into rabbit tibias but no treatment was applied; the TiO-CB (TiO-CB-LZA) (n = 2) and SLA (SLA-LZA) (n = 2) local ZA groups in which 1 mL of normal saline solution containing 2 mg of ZA was injected into sockets and after this the implants were integrated; and the TiO-CB (TiO-CB-SZA) (n = 2) and SLA (SLA-SZA) (n = 2) systemic ZA groups in which a single infusion of 0.1 mg/kg of ZA was administered during surgical implant insertion. Following a period of osseointegration, bone implant contact (BIC) was recorded as a proportion of the total implant surface length in direct contact with the bone. Results of this study indicate that BIC was greater in the systemic ZA application groups than in the local ZA application groups, and BIC was greater in the local ZA groups than in the controls. Statistically significant differences in BIC were not detected between the TiO-CB- and SLA-surfaced implants in all the groups. Furthermore, this study did not reveal significant differences between the 2 types of surfaces due to similar average roughness values. Overall, systemic ZA application was found to be more effective in increasing BIC than local ZA application based on the results obtained by testing 2 implant surfaces.
Effect of alpha-lipoic acid on endometrial implants in an experimental rat model.
Pınar, Neslihan; Soylu Karapınar, Oya; Özcan, Oğuzhan; Özgür, Tümay; Bayraktar, Suphi
2017-10-01
To investigate the antioxidant and anti-inflammatory effects of alpha-lipoic acid (ALA) in the treatment of endometriosis in an experimental rat model by evaluating biochemical and histopathologic parameters. Experimental endometriosis was induced by the peritoneal implantation of autologous endometrial tissue. The rats were randomly divided into two groups with eight rats each. Group I was intraperitoneally administered ALA 100 mg/kg/day for 14 days. Group II was intraperitoneally administered saline solution at the same dosage and over the same period. Endometrial implant volume was measured in both groups both pre- and post-treatment. Tumor necrosis factor alpha (TNF-α) was measured in peritoneal fluid. Total antioxidant status (TAS), total oxidant status (TOS), and oxidative stress index (OSI) were assessed in serum. The implants were histopathologically evaluated. In the ALA group, the serum TOS and OSI levels, the endometrial implant volumes, the TNF-α levels in serum and peritoneal fluid, and the histopathologic scores were significantly lower compared to the control group (P < 0.05). Alpha-lipoic acid may have a therapeutic potential in the treatment of endometriosis due to its antioxidant and anti-inflammatory effects. © 2017 Société Française de Pharmacologie et de Thérapeutique.
Diaz-Gomez, Luis; Concheiro, Angel; Alvarez-Lorenzo, Carmen; García-González, Carlos A
2016-05-20
Synthetic polymeric scaffolds to be used as surrogates of autologous bone grafts should not only have suitable physicochemical and mechanical properties, but also contain bioactive agents such as growth factors (GFs) to facilitate the tissue growth. For this purpose, cost-effective and autologous GFs sources are preferred to avoid some post-surgery complications after implantation, like immunogenicity or disease transmission, and the scaffolds should be processed using methods able to preserve GFs activity. In this work, poly(ɛ-caprolactone) (PCL) scaffolds incorporating GFs were processed using a green foaming process based on supercritical fluid technology. Preparation rich in growth factors (PRGF), a natural and highly available cocktail of GFs obtained from platelet rich plasma (PRP), was used as GF source. PCL:starch:PRGF (85:10:5 weight ratio) porous solid scaffolds were obtained by a supercritical CO2-assisted foaming process at 100 bar and 37 °C with no need of post-processing steps. Bioactivity of GFs after processing and scaffold cytocompatibility were confirmed using mesenchymal stem cells. The performance of starch as GF control release component was shown to be dependent on starch pre-gelification conditions. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Lefebvre, L. P.; Baril, E.
2010-05-01
Porous metals have been used in various orthopedic applications as coating to promote implant fixation or as scaffolds for bone reconstruction. Since these materials were up to recently only used as thin coating (i.e. sintered beads or mesh) and not available into shapes adequate for detailed characterization, the effect of the structure on the static and dynamic properties of these materials has not been widely reported in the literature. This paper presents the effect of the porosity (49.3-66.7%) on the static and dynamic properties of titanium foams produced with a powder metallurgy process. All materials exhibited compression curves with three stages, typical of ductile porous materials. When the porosity level increases, the materials become more brittle. The compression yield strength increases while the modulus is more or less unaffected when the porosity increases from 49.3 to 66.7% and does not follow the power law model accepted for porous medium. The shear strength/adhesion with dense substrates increases with density and is proportional to the compression yield strength. The fatigue limit is not directly link with the porosity. The discrepancies observed are attributed to differences in the structure as the porosity increases.
Xiang, Yiming; Li, Jun; Liu, Xiangmei; Cui, Zhenduo; Yang, Xianjin; Yeung, K W K; Pan, Haobo; Wu, Shuilin
2017-10-01
Poly(lactic-co-glycolic acid)/Ag/ZnO nanorods coating were successfully prepared on the surface of Ti metallic implants using a hydrothermal method and subsequent spin-coating of mixtures of poly(lactic-co-glycolic acid) and silver nanoparticles. The poly(lactic-co-glycolic acid)/Ag/ZnO nanorods coating exhibited excellent antibacterial efficacy of over 96% against both Staphylococcus aureus and Escherichia coli when the initial content of Ag nanoparticles was over 3wt%. In addition, the release of both silver and zinc could last for over a hundred days due to the enwrapping of poly(lactic-co-glycolic acid). Proliferation of mouse calvarial cells exhibited minimal cytotoxicity on the poly(lactic-co-glycolic acid)/Ag/ZnO coating with an initial content of Ag nanoparticles of 1wt% and 3wt%, while it inhibited cell proliferation once this value was increased to 6wt%. The results revealed that this poly(lactic-co-glycolic acid)/Ag/ZnO composite could provide a long-lasting antibacterial approach and good cytocompatibility, thus exhibiting considerable potential for biomedical application in orthopedic and dental implants with excellent self-antibacterial activity and good biocompatibility. Copyright © 2017 Elsevier B.V. All rights reserved.
Fatty acid sulphoalkyl amides and esters as cosmetic surfactants.
Petter, P J
1984-10-01
Synopsis A review is given of the manufacture, properties and applications of the anionic surfactants commonly known as taurates and isethionates (fatty acid sulphoalkyl amides and esters, respectively). Originally developed in the 1930s for textile processing, these surfactants are used increasingly in the cosmetic field, particularly those derived from coconut fatty acid. Both types are produced from sodium isethionate, HO degrees C(2)H(4)SO(3)Na. The acyl isethionate, R degrees COO degrees C(2)H(4)SO(3)Na, is obtained by reaction with a fatty acid ('direct process'). or fatty acid chloride ('indirect process'). The direct process is cheaper but requires extreme conditions which can lead to discoloration of the product and a loss of shorter chain fatty acid components. The N-methyl-N-acyltaurate, R degrees CON(R(1))C(2)H(4)SO(3)Na, is obtained by Schotten-Baumann reaction of a fatty acid chloride with N-methyltaurine, which is derived from sodium isethionate via methylamine. Taurates and isethionates retain the benefits of the soaps to which they are structurally similar, but chemical modifications have eliminated many undesirable features. Thus they combine good detergency and wetting with high foaming, and maintain their performance in hard or salt water. Taurates are stable to hydrolysis over the whole pH range. Isethionates are prone to hydrolysis at high (>8) or low (<5) pH, but this does not normally present a problem in cosmetic formulations. Above all, these surfactants are characterized by their extreme mildness to skin. Syndet and syndet/soap bars based on isethionate can be formulated at neutral pH ('Dove type'bars) instead of the alkaline pH of soap, and have been shown in various studies to be milder than soap and better tolerated by the young, the old and those with sensitive skins. Similarly, isethionates have been shown to be less irritating than other anionic or amphoteric surfactants used in cosmetics. The difference has been related to the negligible effect of isethionate on the water-binding capacity of stratum corneum. Other cosmetic applications besides toilet bars include shampoos (excellent cleaning, mild to scalp, some hair conditioning effects), liquid soaps (mild for all-over body use), bubble baths (copious stable foam, efficient lime soap dispersal, low irritancy), skin creams and lotions (emulsification, alleviation of 'dry skin'), baby care products (ultra-mild cleansing bars and milks, impregnated baby wipes) and oral products (foaming agents with low toxicity for toothpastes and mouthwashes).
Jungheim, Emily S; Frolova, Antonina I; Jiang, Hui; Riley, Joan K
2013-08-01
Polyunsaturated fatty acids (PUFAs) and their metabolism may be important in normal reproductive function and fertility. Associations between physiologic PUFAs and pregnancy have not been established in women. The purpose of this study was to investigate associations between serum levels of PUFAs and embryo implantation in women undergoing in vitro fertilization (IVF). This was a prospective cohort study conducted between 2010 and 2012. The study was conducted at the Washington University Reproductive Medicine Center. Participants were 200 women undergoing IVF and participating in an ongoing specimen tissue bank. Fasting serum PUFAs were measured with liquid chromatography-mass spectroscopy. PUFAs measured included linoleic acid (LA), α-linolenic acid (ALA), eicosapentaenoic acid, arachidonic acid, and docosahexaenoic acid. Relationships between serum levels of measured PUFAs and embryo implantation in women undergoing IVF were analyzed. In unadjusted analyses, none of the PUFAs alone were associated with a chance of pregnancy; however, women with increased LA:ALA ratios had a higher chance of pregnancy compared with women with lower LA:ALA ratios (relative risk, 1.52; 95% confidence interval, 1.09-2.13). This relationship held after multivariable logistic regression adjusting for age, antral follicle count, body mass index, history of previous pregnancy, and history of endometriosis (odds ratio, 2.7; 95% confidence interval, 1.3-5.7). Embryo implantation rates were also weakly associated with LA:ALA ratios (r = 0.21, P = .003). Our work shows that increased ω-6 to ω-3 PUFA ratios in women undergoing IVF are associated with increased implantation and pregnancy rates. Prospective trials are needed to determine whether manipulation of PUFA ratios through diet or pharmacologic intervention may benefit women planning to conceive.
Zheng, Haixiang; Fu, Yucai; Huang, Yusheng; Zheng, Xinde; Yu, Wei; Wang, Wei
2017-09-01
Atherosclerosis (AS) is a chronic immuno‑inflammatory disease accompanied by dyslipidemia. The authors previously demonstrated that sirtuin 1 (SIRT1) may prevent atherogenesis through influencing the liver X receptor/C‑C chemokine receptor type 7/nuclear factor‑κB (LXR‑CCR7/NF‑κB) signaling pathway. Previous studies have suggested a role for mammalian target of rapamycin (mTOR) signaling in the pathogenesis of cardiovascular diseases. The present study investigated the potential association between mTOR signaling and SIRT1‑LXR‑CCR7/NF‑κB signaling (SIRT1 signaling) in AS pathogenesis. To induce foam cell formation, U937 cells were differentiated into macrophages by exposure to phorbol 12‑myristate 13‑acetate (PMA) for 24 h, followed by treatment with palmitate and oxidized low density lipoprotein for a further 24 h. Oil red O staining revealed a large accumulation of lipid droplets present in foam cells. Western blot analysis demonstrated increased protein levels of phosphorylated (p)‑mTOR and its downstream factor p‑ribosomal protein S6 kinase (p70S6K). Reverse transcription‑quantitative polymerase chain reaction and western blot analyses additionally revealed decreased expression of SIRT1, LXRα and CCR7 and increased expression of NF‑κB and its downstream factor tumor necrosis factor‑α (TNF‑α) in an atherogenetic condition induced by lysophosphatidic acid (LPA). In addition, abundant lipid droplets accumulated in U937‑LPA‑treated foam cells. Rapamycin, an mTOR inhibitor, suppressed the expression and activity of mTOR and p70S6K, however enhanced expression of SIRT1, LXRα, and CCR7. Conversely, rapamycin deceased TNF‑α and NF‑κB activity, the latter of which was further confirmed by immunofluorescence analysis demonstrating increased levels of NF‑κB present in the cytoplasm compared with the nucleus. The findings of the present study suggest that mTOR signaling promotes foam cell formation and inhibits foam cell egress via suppression of SIRT1 signaling.
Manna, Soumyarwit; Banerjee, Rupak K; Augsburger, James J; Al-Rjoub, Marwan F; Donnell, Anna; Correa, Zelia M
2015-08-01
The purpose of this study was to evaluate the pharmacokinetics and toxicity of a chitosan (CS) and polylactic acid (PLA) based methotrexate (MTX) intravitreal micro-implant in an animal model using rabbit eyes. CS- and PLA-based micro-implants containing 400 μg of MTX were fabricated using lyophilization and dip-coating techniques. The micro-implants were surgically implanted in the vitreous of eight New Zealand rabbits employing minimally invasive technique. The PLA-coated CS-MTX micro-implant was inserted in the right eye and the placebo micro-implant in the left eye of each rabbit. Two rabbits were euthanized at each pre-determined time point post-implantation (days 5, 12, 19, and 33) for pharmacokinetics and histopathology evaluation. A therapeutic concentration of MTX (0.1-1.0 μM) in the vitreous was detected in the rabbit eyes studied for 33 days. The MTX release from the coated micro-implants followed a first order kinetics (R (2) ~ 0.88), implying that MTX release depends on the concentration of MTX in the micro-implant. Histopathological analysis of the enucleated eyes failed to show any signs of infection or tissue toxicity in any of the specimens. The PLA-coated CS-MTX micro-implants were able to deliver therapeutic release of MTX for a period of more than 1 month without detectable toxicity in a rabbit model. The micro-implants can be further investigated as a prospective alternative to current treatment protocols of repeated intravitreal MTX injections in intraocular disorders such as primary intraocular lymphoma, and selected cases of non-microbial intraocular inflammation.
[Treatment of acrylate wastewater by electrocatalytic reduction process].
Yu, Li-Na; Song, Yu-Dong; Zhou, Yue-Xi; Zhu, Shu-Quan; Zheng, Sheng-Zhi; Ll, Si-Min
2011-10-01
High-concentration acrylate wastewater was treated by an electrocatalytic reduction process. The effects of the cation exchange membrane (CEM) and cathode materials on acrylate reduction were investigated. It indicated that the acrylate could be reduced to propionate acid efficiently by the electrocatalytic reduction process. The addition of CEM to separator with the cathode and anode could significantly improve current efficiency. The cathode materials had significant effect on the reduction of acrylate. The current efficiency by Pd/Nickel foam, was greater than 90%, while those by nickel foam, the carbon fibers and the stainless steel decreased successively. Toxicity of the wastewater decreased considerably and methane production rate in the biochemical methane potential (BMP) test increased greatly after the electrocatalytic reduction process.
Mutagenicity of aerosols from the oxidative thermal decomposition of rigid polyurethane foam.
Zitting, A; Falck, K; Skyttä, E
1980-01-01
The aerosol fraction of the oxidative thermal decomposition products (700 degrees C) of rigid polyurethane foam was collected on glass fiber filters and fractionated into either-soluble neutral, acidic, and basic fractions and water-soluble compounds. The fractions showed mutagenic activity in a bacterial fluctuation test with Salmonella typhimurium TA98 or Escherichia coli CM891 as the tester strains. All the fractions induced mutations in both strains after metabolic activation with rat liver S-9 mix. The basic and the water-soluble fractions were mutagenic for S. typhimurium TA 98 even without activation. Thin-layer chromatography showed the presence of several primary aromatic amines in the aerosol. Polycyclic aromatic hydrocarbons were not detected by glass capillary gas chromatogaphy.
NASA Astrophysics Data System (ADS)
Khort, Alexander; Podbolotov, Kirill; Serrano-García, Raquel; Gun'ko, Yurii K.
2017-09-01
In this paper, we report a new modified one-step combustion synthesis technique for production of Ni metal nanoparticles. The main unique feature of our approach is the use of microwave assisted foam preparation. Also, the effect of different types of fuels (urea, citric acid, glycine and hexamethylenetetramine) on the combustion process and characteristics of resultant solid products were investigated. It is observed that the combination of microwave assisted foam preparation and using of hexamethylenetetramine as a fuel allows producing pure ferromagnetic Ni metal nanoparticles with enhanced coercivity (78 Oe) and high value of saturation magnetization (52 emu/g) by one-step solution combustion synthesis under normal air atmosphere without any post-reduction processing.
Preparation and characterization of N-benzoyl-O-acetyl-chitosan.
Cai, Jinping; Dang, Qifeng; Liu, Chengsheng; Fan, Bing; Yan, Jingquan; Xu, Yanyan; Li, Jingjing
2015-01-01
A novel amphipathic chitosan derivative, N-benzoyl-O-acetyl-chitosan (BACS), was prepared by using the selective partial acylation of chitosan (CS), benzoyl chloride, and acetic acid under high-intensity ultrasound. The chemical structure and physical properties of BACS were characterized by FTIR, (1)H NMR, TGA, and XRD techniques. The degrees of substitution of benzoyl and acetyl for the chitosan derivatives were 0.26 and 1.15, respectively, which were calculated from the peak areas in NMR spectra by using the combined integral methods. The foaming properties of CS and BACS were determined and the results suggested BACS had better foam capacity and stability than those of chitosan. In addition, the antimicrobial activities of CS and BACS were also investigated against two species of bacteria (Escherichia coli and Staphylococcus aureus) and a fungus (Aspergillus niger), the results indicated that the antibacterial and antifungal activities of BACS were much stronger than those of the parent chitosan. These findings suggested that BACS was preferable for use as a food additive with a dual role of both foaming agent and food preservative. Copyright © 2015 Elsevier B.V. All rights reserved.
Haka, Abigail S.; Barbosa-Lorenzi, Valéria C.; Lee, Hyuek Jong; Falcone, Domenick J.; Hudis, Clifford A.; Dannenberg, Andrew J.
2016-01-01
Many types of apoptotic cells are phagocytosed and digested by macrophages. Adipocytes can be hundreds of times larger than macrophages, so they are too large to be digested by conventional phagocytic processes. The nature of the interaction between macrophages and apoptotic adipocytes has not been studied in detail. We describe a cellular process, termed exophagy, that is important for macrophage clearance of dead adipocytes and adipose tissue homeostasis. Using mouse models of obesity, human tissue, and a cell culture model, we show that macrophages form hydrolytic extracellular compartments at points of contact with dead adipocytes using local actin polymerization. These compartments are acidic and contain lysosomal enzymes delivered by exocytosis. Uptake and complete degradation of adipocyte fragments, which are released by extracellular hydrolysis, leads to macrophage foam cell formation. Exophagy-mediated foam cell formation is a highly efficient means by which macrophages internalize large amounts of lipid, which may ultimately overwhelm the metabolic capacity of the macrophage. This process provides a mechanism for degradation of objects, such as dead adipocytes, that are too large to be phagocytosed by macrophages. PMID:27044658
Wu, Liqiong; Li, Weiwei; Li, Peng; Liao, Shutian; Qiu, Shengqiang; Chen, Mingliang; Guo, Yufen; Li, Qi; Zhu, Chao; Liu, Liwei
2014-04-09
A facile and high-yield approach to the preparation of few-layer graphene (FLG) by electrochemical intercalation exfoliation (EIE) of expanded graphite in sulfuric acid electrolyte is reported. Stage-1 H2SO4-graphite intercalation compound is used as a key intermediate in EIE to realize the efficient exfoliation. The yield of the FLG sheets (<7 layers) with large lateral sizes (tens of microns) is more than 75% relative to the total amount of starting expanded graphite. A low degree of oxygen functionalization existing in the prepared FLG flakes enables them to disperse effectively, which contributes to the film-forming characteristics of the FLG flakes. These electrochemically exfoliated FLG flakes are integrated into several kinds of macroscopic graphene structures. Flexible and freestanding graphene papers made of the FLG flakes retain excellent conductivity (≈24,500 S m(-1)). Three-dimensional (3D) graphene foams with light weight are fabricated from the FLG flakes by the use of Ni foams as self-sacrifice templates. Furthermore, 3D graphene/Ni foams without any binders, which are used as supercapacitor electrodes in aqueous electrolyte, provide the specific capacitance of 113.2 F g(-1) at a current density of 0.5 A g(-1), retaining 90% capacitance after 1000 cycles. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Biodegradable implants from poly-(alpha-hydroxy acid) polymers for isoniazid delivery.
Hurley, L; Andersen, B R
1999-11-01
In vitro and in vivo study of an isoniazid (INH) drug delivery system. To develop a system for the treatment of tuberculosis using a subcutaneous polymer implant with a large drug load released slowly over a long period. INH delivery by biodegradable poly-(alpha-hydroxy acid) polymers was evaluated using ground polymer and compression molded implants. Rate of drug release and structural stability of the implant in an aqueous environment were measured, as were in vivo evaluations of the duration of measurable levels of INH in serum and urine. Factors that influenced the suitability of an implant in an in vitro system included polymer molecular weight and crystallinity, polymer and drug particle size, drug loading dose, and press temperature and pressure. The implant characteristics that most closely approached optimal conditions include a polymer of 100% L-lactide with low intrinsic viscosity, polymer particle size <75 micron, and INH particle = 126-180 micron, INH loading dose not to exceed 46%, and press conditions of 70 degrees C and 345000 kPa. Studies of subcutaneous implants in rabbits and baboons show that INH is released from the implant for 15 to 26 weeks. An INH-containing polymer was developed that was structurally stable in an aqueous environment and that released INH over a period of at least 15 weeks. Studies with infected animals will be necessary to determine the dose required for prophylaxis and treatment of active disease.
Yu, Fei; Addison, Owen; Baker, Stephen J; Davenport, Alison J
2015-01-01
Titanium and its alloys are routinely used as biomedical implants and are usually considered to be corrosion resistant under physiological conditions. However, during inflammation, chemical modifications of the peri-implant environment including acidification occur. In addition certain biomolecules including lipopolysaccharide (LPS), a component of Gram-negative bacterial cell walls and driver of inflammation have been shown to interact strongly with Ti and modify its corrosion resistance. Gram-negative microbes are abundant in biofilms which form on dental implants. The objective was to investigate the influence of LPS on the corrosion properties of relevant biomedical Ti substrates as a function of environmental acidity. Inductively coupled plasma mass spectrometry was used to quantify Ti dissolution following immersion testing in physiological saline for three common biomedical grades of Ti (ASTM Grade 2, Grade 4 and Grade 5). Complementary electrochemical tests including anodic and cathodic polarisation experiments and potentiostatic measurements were also conducted. All three Ti alloys were observed to behave similarly and ion release was sensitive to pH of the immersion solution. However, LPS significantly inhibited Ti release under the most acidic conditions (pH 2), which may develop in localized corrosion sites, but promoted dissolution at pH 4–7, which would be more commonly encountered physiologically. The observed pattern of sensitivity to environmental acidity of the effect of LPS on Ti corrosion has not previously been reported. LPS is found extensively on the surfaces of skin and mucosal penetrating Ti implants and the findings are therefore relevant when considering the chemical stability of Ti implant surfaces in vivo. PMID:25634122
NASA Astrophysics Data System (ADS)
Zhou, Xiuhong; Ge, Chunmei; Yao, Jianming; Pan, Renrui; Yu, Zengliang
2005-10-01
In order to obtain an industrial strain with a higher L(+)-lactic acid yield, the strain Rhizopus oryzae RF3608 was mutated by means of nitrogen ion beam implantation and the mutant strain RLC41-6 was isolated. Under optimal conditions the yield of L(+)-lactic acid produced in a shake-flask reached 133 g/L-137 g/L after 36 h cultivation, indicating that the conversion rate based on glucose was as high as 88%-91% and the productivity was 3.75 g/L.h. It was almost a 115% increase in lactic acid production compared with the original strain RF3608.
In vitro and in vivo mechanical stability of orthodontic mini-implants.
Cho, Il-Sik; Kim, Sung-Kyun; Chang, Young-Il; Baek, Seung-Hak
2012-07-01
To compare in vivo and in vitro mechanical stability of orthodontic mini-implants (OMIs) treated with a sandblasted, large-grit, and anodic-oxidation (SLAO) method vs those treated with a sandblasted, large-grit, and acid-etching (SLA) method. Fifty-four titanium OMIs (cylindrical shape, drill-free type; diameter = 1.45 mm, length = 8 mm, Biomaterials Korea Inc, Seoul, Korea) were allocated into control, SLA, and SLAO groups (N = 12 for in vivo and N = 6 for in vitro studies per group). In vitro study was carried out on a polyurethane foam bone block (Sawbones, Pacific Research Laboratories Inc, Vashon, Wash). In vivo study was performed in the tibias of Beagles (6 males, age = 1 year, weight = 10 to 13 kg; OMIs were removed at 8 weeks after installation). For insertion and removal of OMIs, the speed and maximum torque of the surgical engine were set to 30 rpm and 40 Ncm, respectively. Maximum torque (MT), total energy (TE), and near peak energy (NPE) during the insertion and removal procedures were statistically analyzed. In the in vitro study, although the control group had a higher insertion MT value than the SLA and SLAO groups (P < .01), no differences in insertion TE and NPE or in any of the removal variables were noted among the three groups. In the in vivo study, the control group exhibited higher values for all insertion variables compared with the SLA and SLAO groups (MT, P < .001; TE, P < .01; NPE, P < .001). Although no difference in removal TE and removal NPE was noted among the three groups, the SLAO group presented with a higher removal MT than the SLA and control groups (P < .001). SLAO treatment may be an effective tool in reducing insertion damage to surrounding tissue and improving the mechanical stability of OMIs.
Lee, Jae-Wang; An, Jun Hyeong; Park, Sang-Hoon; Chong, Jong-Hyon; Kim, Gwang-Seok; Han, JeongJoon; Jung, Seunggon; Kook, Min-Suk; Oh, Hee-Kyun; Ryu, Sun-Youl; Park, Hong-Ju
2016-12-01
The purpose of this retrospective study was to evaluate the clinical utility of an implant with a sandblasted, large-grit, acid-etched (SLA) surface and internal connection. Six patients who received dental implants in the Department of Oral and Maxillofacial Surgery, Chonnam National University Dental Hospital, were analyzed by factors influencing the success rate and marginal bone loss. Factors included patient's age, sex, implant installation site, whether bone graft was done, type of bone graft materials, approaching method if sinus lift was done, and the size of the fixture. In addition, the marginal bone loss was analyzed by using a radiograph. All implants were successful, and the cumulative survival rate was 100 %. Average marginal bone loss of 6 months after the installation was 0.52 mm and 20 months after the functional loading was 1.06 mm. Total marginal bone resorption was 1.58 mm on average. There was no statistically significant difference in mesial and distal marginal bone loss. The short-term clinical success rate of the implant with an SLA surface and internal connection was satisfactory. Moreover, the marginal bone loss was also consistent with the implant success criteria.
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
Polyols from microwave liquefied bagasse and its application to rigid polyurethane foam
Jiulong Xie; Xianglin Zhai; Chung Hse; Todd Shupe; Hui Pan
2015-01-01
Bagasse flour (BF) was liquefied using bi-component polyhydric alcohol (PA) as a solventand phosphoric acid as a catalyst in a microwave reactor. The effect of BF to solvent ratio andreaction temperatures on the liquefaction extent and characteristics of liquefied products wereevaluated. The results revealed that almost 75% of the...
USDA-ARS?s Scientific Manuscript database
Consuming curcumin may benefit health by modulating lipid metabolism and suppressing atherogenesis. Fatty acid binding proteins (FABP-4/aP2) and CD36 expression are key factors in lipid accumulation in macrophages and foam cell formation in atherogenesis. Our earlier observations suggest that curcum...
Liang, Min-Yi; Chen, Yongsheng; Banwell, Martin G; Wang, Yong; Lan, Ping
2018-04-18
Sugar fatty acid esters are nonionic surfactants that are widely exploited in the food and cosmetics industries, as well as in the oral care and medical supply fields. Accordingly, new methods for their selective synthesis and the "tuning" of their emulsifying properties are of considerable interest. Herein we report simple and irreversible enzymatic esterifications of d-glucose with seven fatty acid vinyl esters. The foaming and emulsifying effects of the resulting 6- O-acylglucose esters were then evaluated. In accord with expectations, when the length of the alkyl side chain associated with the 6- O-acylglucose esters increases, then their hydrophilic-lipophilic balance (HLB) values decrease, while the stabilities of the derived emulsions improve. In order to maintain good foaming properties, alkyl side chains of at least 9 to 11 carbons in length are required. In the first such assays on 6- O-acylglucose esters, most of those described herein are shown to be nontoxic to the HepG2, MCF-7, LNacp, SW549, and LO-2 cell lines.
Gulzar, Muhammad; Taylor, John Rn; Minnaar, Amanda
2017-11-01
Marama bean protein, as extracted previously at pH 8, forms a viscous, adhesive and extensible dough. To obtain a protein isolate with optimum functional properties, protein extraction under slightly acidic conditions (pH 6) was investigated. Two-dimensional electrophoresis showed that pH 6 extracted marama protein lacked some basic 11S legumin polypeptides, present in pH 8 extracted protein. However, it additionally contained acidic high molecular weight polypeptides (∼180 kDa), which were disulfide crosslinked into larger proteins. pH 6 extracted marama proteins had similar emulsification properties to soy protein isolate and several times higher foaming capacity than pH 8 extracted protein, egg white and soy protein isolate. pH 6 extracted protein dough was more elastic than pH 8 extracted protein, approaching the elasticity of wheat gluten. Marama protein extracted at pH 6 has excellent food-type functional properties, probably because it lacks some 11S polypeptides but has additional high molecular weight proteins. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Al-Farga, Ammar; Zhang, Hui; Siddeeg, Azhari; Shamoon, Muhammad; V M Chamba, Moses; Al-Hajj, Nabil
2016-11-15
Alhydwan (Boerhavia elegana Choisy) seed flour was evaluated for chemical and nutritional composition, and functional properties in a pursuit to identify an innovative plant with high nutraceuticals value which could be exploited in other food applications. The flour was found to be rich in dietary fiber (30.13%), protein (14.60%), crude fat (11.49%), carbohydrates (30.77%), and ash (6.88%) and encompassed adequate amounts of essential amino acids and minerals, whereas, sucrose constituted 71.3% of total sugar contents. Vitamins analysis revealed that flour is rich in water-soluble vitamins such as Thiamin (B1), Riboflavin (B2) and Niacin (B3), to the amounts of 19.3, 8.2 and 2.3mg/100g, respectively. Results on functional properties demonstrated high water and oil absorption capacities of 6.31 and 2.43g/g, respectively. Foaming capacity, foam stability and emulsion capacity were 9.35%, 6.90%, and 29.60%, respectively. It can be concluded that alhydwan is an excellent food material with a high nutritional value. Copyright © 2016 Elsevier Ltd. All rights reserved.
Lichtenstein, Laeticia; Mattijssen, Frits; de Wit, Nicole J; Georgiadi, Anastasia; Hooiveld, Guido J; van der Meer, Roelof; He, Yin; Qi, Ling; Köster, Anja; Tamsma, Jouke T; Tan, Nguan Soon; Müller, Michael; Kersten, Sander
2010-12-01
Dietary saturated fat is linked to numerous chronic diseases, including cardiovascular disease. Here we study the role of the lipoprotein lipase inhibitor Angptl4 in the response to dietary saturated fat. Strikingly, in mice lacking Angptl4, saturated fat induces a severe and lethal phenotype characterized by fibrinopurulent peritonitis, ascites, intestinal fibrosis, and cachexia. These abnormalities are preceded by a massive acute phase response induced by saturated but not unsaturated fat or medium-chain fat, originating in mesenteric lymph nodes (MLNs). MLNs undergo dramatic expansion and contain numerous lipid-laden macrophages. In peritoneal macrophages incubated with chyle, Angptl4 dramatically reduced foam cell formation, inflammatory gene expression, and chyle-induced activation of ER stress. Induction of macrophage Angptl4 by fatty acids is part of a mechanism that serves to reduce postprandial lipid uptake from chyle into MLN-resident macrophages by inhibiting triglyceride hydrolysis, thereby preventing macrophage activation and foam cell formation and protecting against progressive, uncontrolled saturated fat-induced inflammation. Copyright © 2010 Elsevier Inc. All rights reserved.
The Initial Inflammatory Response to Bioactive Implants Is Characterized by NETosis
Stoiber, Walter; Hannig, Matthias; Klappacher, Michaela; Hartl, Dominik
2015-01-01
Implants trigger an inflammatory response, which is important for osseointegration. Here we studied neutrophil extracellular trap (NET) release of human neutrophils in response to sandblasted large-grit acid etched (SLA) implants using fluorescent, confocal laser scanning and scanning electron microscopy. Our studies demonstrate that human neutrophils rapidly adhered to SLA surfaces, which triggered histone citrullination and NET release. Further studies showed that albumin or acetylsalicylic acid had no significant effects on the inflammatory response to SLA surfaces. In contrast to bioinert materials, which do not osseointegrate, the bioactivity of SLA surfaces is coupled with the ability to release NETs. Further investigations are necessary for clarifying the role of NETosis for osseointegration. PMID:25798949
Salmonella transfer during pilot plant scale washing and roller conveying of tomatoes.
Wang, Haiqiang; Ryser, Elliot T
2014-03-01
Salmonella transfer during washing and roller conveying of inoculated tomatoes was quantified using a pilot scale tomato packing line equipped with plastic, foam, or brush rollers. Red round tomatoes (2.3 kg) were dip inoculated with Salmonella enterica serovar Typhimurium LT2 (avirulent) (4 log CFU/g), air dried for 2 h, and then washed in sanitizer-free water for 2 min. Inoculated tomatoes were then passed single file over a 1.5-m conveyor equipped with plastic, foam, or brush rollers followed by 25 previously washed uninoculated tomatoes. Tomato samples were collected after 2 min of both washing and roller conveying, with all 25 uninoculated tomatoes collected individually after conveying. Roller surface samples were collected before and after conveying the uninoculated tomatoes. Both tomato and surface samples were quantitatively examined for Salmonella by direct plating or membrane filtration using xylose lysine Tergitol 4 agar. Regardless of the roller type, Salmonella populations on inoculated tomatoes did not significantly (P < 0.05) decrease during contact with the roller conveyors. After conveying uninoculated tomatoes over contaminated foam rollers, 96% of the 25 tomatoes were cross-contaminated with Salmonella at >100 CFU per tomato. With plastic rollers, 24 and 76% of tomatoes were cross-contaminated with Salmonella at 10 to 100 and 1 to 10 CFU per tomato, respectively. In contrast, only 8% of 25 tomatoes were cross-contaminated with brush rollers with Salmonella populations of 1 to 10 CFU per tomato. Overall, cross-contamination was greatest with foam, followed by plastic and brush rollers (P < 0.05). Adding peroxyacetic acid or chlorine to the wash water significantly decreased cross-contamination during tomato conveying, with chlorine less effective in controlling Salmonella on foam compared with plastic and brush rollers.
[Construction of a multiple-scale implant surface with super-hydrophilicity].
Luo, Qiao-jie; Li, Xiao-dong; Huang, Ying; Zhao, Shi-fang
2012-05-01
To construct a multiple-scale organized implant surface with super-hydrophilicity. The SiC paper polished titanium disc was sandblasted and treated with HF/HNO₃ and HCl/H₂SO₄, then acid-etched with H₂SO₄/H₂O₂. The physicochemical properties of the surfaces were characterized by scanning electron microscope, static state contact angle and X-ray diffraction. MC3T3-E1 cells were used to evaluate the effects of the surface on the cell adhesion, proliferation and differentiation. The acid-etching process with a mixture of H₂SO₄/H₂O₂ superimposed the nano-scale structure on the micro-scale texture. The multiple-scale implant surface promoted its hydrophilicity and was more favorable to the responses of osteoprogenitor cells, characterized by increased DNA content, enhanced ALP activity and promoted OC production. A multiple-scale implant surface with super-hydrophilicity has been constructed in this study, which facilitates cell proliferation and adhesion.
Insights on Flow Behavior of Foam in Unsaturated Porous Media during Soil Flushing.
Zhao, Yong S; Su, Yan; Lian, Jing R; Wang, He F; Li, Lu L; Qin, Chuan Y
2016-11-01
One-dimensional column and two-dimensional tank experiments were carried out to determine (1) the physics of foam flow and propagation of foaming gas, foaming liquid, and foam; (2) the pressure distribution along foam flow and the effect of media permeability, foam flow rate and foam quality on foam injection pressure; and (3) the migration and distribution property of foam flow in homogeneous and heterogeneous sediments. The results demonstrated that: (1) gas and liquid front were formed ahead of the foam flow front, the transport speed order is foaming gas > foaming liquid > foam flowing; (2) injection pressure mainly comes from the resistance to bubble migration. Effect of media permeability on foam injection pressure mainly depends on the physics and behavior of foam flow; (3) foam has a stronger capacity of lateral spreading, besides, foam flow was uniformly distributed across the foam-occupied region, regardless of the heterogeneity of porous media.
Microstructures and Mechanical Study of Mg Alloy Foam Based on Mg-Zn-Ca-CaCO3 System
NASA Astrophysics Data System (ADS)
Erryani, A.; Pramuji, F.; Annur, D.; Amal, M. I.; Kartika, I.
2017-05-01
Magnesium alloy, a material that has potential to use some applications such as aerospace components, computer parts, and mobile phones. Magnesium alloy can also be a popular candidate as an orthopedic implant material for biodegradability, non-toxicity, and mechanical and physical properties that are excellent. Magnesium, one of the main macro elements required for the proper functioning of the human organism, is used to test the materials for biodegradable implants. The main objective of this study was to find out the microstructure, and mechanical characteristics of the Mg-Ca-Zn-CaCO3 alloy as porous implant materials are biodegradable. The presence of CaCO3 on the alloy functions as a foaming agent expected to produce gas bubbles during manufacturing process taken place that will form pores in the alloy. Mg-Ca-Zn-CaCO3 alloy was made by powder metallurgy method with three variations of composition (96Mg-Ca-3Zn-CaCO3, 91Mg-Ca-3Zn-5CaCO3, and 86Mg-Ca-3Zn-10CaCO3 wt%). Milling process was by using a shaker mill for 2 hours to produce a powder size distribution which was more homogeneous. The mixed powder was uniaxially pressed at a pressure of 100 MPa for 2 minutes and 200 MPa for 3 minutes into green compacts with dimensions of 10 mm in diameter and 10 mm in length. The sintering process was carried out at 650°C with a variation of holding time of 10 and 15 hours, and then the specimens were cooled down at room temperature. Microstructural analysis was performed by using X-Ray diffraction technique and Scanning electron microscopy equipped with an energy disperse spectrometry (EDS). The mechanical characteristics were analyzed by using Universal Testing Machine. The density and porosity of specimen were further measured by using Archimedes method. The results show that the optimum microstructure and mechanical characteristics are the holding time of 10 hours. The value of compression was 208.398 N/mm2, the density was 1.63 g/cc and a porosity was 18% on the composition of 86Mg-Ca-3Zn-10CaCO3 wt%.
NASA Astrophysics Data System (ADS)
Muller, Ludovic; Baldwin, Kathrine; Barbacci, Damon C.; Jackson, Shelley N.; Roux, Aurélie; Balaban, Carey D.; Brinson, Bruce E.; McCully, Michael I.; Lewis, Ernest K.; Schultz, J. Albert; Woods, Amina S.
2017-08-01
Mass spectrometry imaging (MSI) of tissue implanted with silver nanoparticulate (AgNP) matrix generates reproducible imaging of lipids in rodent models of disease and injury. Gas-phase production and acceleration of size-selected 8 nm AgNP is followed by controlled ion beam rastering and soft landing implantation of 500 eV AgNP into tissue. Focused 337 nm laser desorption produces high quality images for most lipid classes in rat brain tissue (in positive mode: galactoceramides, diacylglycerols, ceramides, phosphatidylcholines, cholesteryl ester, and cholesterol, and in negative ion mode: phosphatidylethanolamides, sulfatides, phosphatidylinositol, and sphingomyelins). Image reproducibility in serial sections of brain tissue is achieved within <10% tolerance by selecting argentated instead of alkali cationized ions. The imaging of brain tissues spotted with pure standards was used to demonstrate that Ag cationized ceramide and diacylglycerol ions are from intact, endogenous species. In contrast, almost all Ag cationized fatty acid ions are a result of fragmentations of numerous lipid types having the fatty acid as a subunit. Almost no argentated intact fatty acid ions come from the pure fatty acid standard on tissue.
Tabata, Tomonori; Kaku, Nobuhiro; Hara, Katsutoshi; Tsumura, Hiroshi
2015-04-01
Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.
Bittar, Roseli Saraiva Moreira; Sato, Eduardo Setsuo; Ribeiro, Douglas Jósimo Silva; Tsuji, Robinson Koji
Cochlear implants are undeniably an effective method for the recovery of hearing function in patients with hearing loss. To describe the preoperative vestibular assessment protocol in subjects who will be submitted to cochlear implants. Our institutional protocol provides the vestibular diagnosis through six simple tests: Romberg and Fukuda tests, assessment for spontaneous nystagmus, Head Impulse Test, evaluation for Head Shaking Nystagmus and caloric test. 21 patients were evaluated with a mean age of 42.75±14.38 years. Only 28% of the sample had all normal test results. The presence of asymmetric vestibular information was documented through the caloric test in 32% of the sample and spontaneous nystagmus was an important clue for the diagnosis. Bilateral vestibular areflexia was present in four subjects, unilateral arreflexia in three and bilateral hyporeflexia in two. The Head Impulse Test was a significant indicator for the diagnosis of areflexia in the tested ear (p=0.0001). The sensitized Romberg test using a foam pad was able to diagnose severe vestibular function impairment (p=0.003). The six clinical tests were able to identify the presence or absence of vestibular function and function asymmetry between the ears of the same individual. Copyright © 2016 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Cleansing and surface modifying agents on implants: fixation and related aspects of aesthetics.
Ling, B C; Gillings, B R
1995-01-01
With the prognosis of dental implant replacement of missing teeth becoming better each year, practitioners are focusing their attention on the aesthetic aspects of implantology. However, improvement in aesthetics is only possible with the improvement in implant technology, surgical techniques and prosthodontic procedures. This study aimed at evaluating the effects of various physical and chemical agents on the implant surface; with the view of obtaining increased surface area and biocompatibility. The study found that the treatment of air-aluminum oxide blasted implants using a mixture of 30% HNO3-5% HF acids produced a surface which meets the consideration of aesthetics for implants placed in the anterior maxillary region.
Gandolfi, M G; Taddei, P; Siboni, F; Perrotti, V; Iezzi, G; Piattelli, A; Prati, C
2015-02-01
The creation of micro-textured dental implant surfaces possessing a stimulating activity represents a challenge in implant dentistry; particularly, the formation of a thin, biologically active, calcium-phosphate layer on their surface could help to strengthen the bond to the surrounding bone. The aim of the present study was to characterize in terms of macrostructure, micro-topography and reactivity in simulated body fluid (SBF), the surface of titanium (Ti) implants blasted with TiO2 particles, acid etched with hydrofluoric acid, and activated with Ca and Mg-containing nanoparticles. Sandblasted and acid-etched implants were analyzed by ESEM-EDX (environmental scanning electron microscope with energy dispersive X-ray system) to study the micromorphology of the surface and to perform elemental X-ray microanalysis (microchemical analyses) and element mapping. ESEM-EDX analyses were performed at time 0 and after a 28-day soaking period in SBF Hank's balanced salt solution (HBSS) following ISO 23317 (implants for surgery—in vitro evaluation for apatite-forming ability of implant materials). Microchemical analyses (weight % and atomic %) and element mapping were carried out to evaluate the relative element content, element distribution, and calcium/phosphorus (Ca/P) atomic ratio. Raman spectroscopy was used to assess the possible presence of impurities due to manufacturing and to investigate the phases formed upon HBSS soaking. Micro-morphological analyses showed a micro-textured, highly rough surface with microgrooves. Microchemical analyses showed compositional differences among the apical, middle, and distal thirds. The micro-Raman analyses of the as-received implant showed the presence of amorphous Ti oxide and traces of anatase, calcite, and a carbonaceous material derived from the decomposition of an organic component of lipidic nature (presumably used as lubricant). A uniform layer of Ca-poor calcium phosphates (CaPs) (Ca/P ratio <1.47) was observed after soaking in HBSS; the detection of the 961 cm⁻¹ Raman band confirms this finding. These implants showed a micro-textured surface supporting the formation of CaPs when immersed in SBF. These properties may likely favor bone anchorage and healing by stimulation of mineralizing cells.
Schwarz, Frank; Sager, Martin; Kadelka, Ines; Ferrari, Daniel; Becker, Jürgen
2010-05-01
The aim of the present study was to compare bone regeneration in dehiscence-type defects at titanium implants with chemically modified sandblasted/acid-etched (modSLA) or dual acid-etched surfaces with a calcium phosphate nanometre particle modification (DCD/CaP). Buccal dehiscence-type defects were surgically created following implant site preparation in both the upper and the lower jaws of 12 fox hounds. Both types of implants were randomly allocated in a split-mouth design and left to heal in a submerged position for 2 and 8 weeks. Dissected blocks were processed for histomorphometrical analysis [e.g. new bone height (NBH), percentage of bone-to-implant contact (BIC), area of new bone fill (BF), and area of mineralized tissue (MT) within BF]. At 2 and 8 weeks, both groups revealed comparable mean BF (2.3+/-0.6 to 2.5+/-0.6 mm(2)versus 2.0+/-0.6 to 1.4+/-0.5 mm(2)) and MT (31.1+/-14.3-83.2+/-8.2%versus 38.9+/-15.9-84.4+/-6.3%) values. However, modSLA implants revealed significantly higher mean NBH (2.4+/-0.8 to 3.6+/-0.3 mm versus 0.9+/-0.8 to 1.8+/-1.4 mm) and BIC (53.3+/-11.3-79.5+/-6.6%versus 19.3+/-16.4-47.2+/-30.7%) values than DCD/CaP implants. ModSLA implants may have a higher potential to support osseointegration in dehiscence-type defects than DCD/CaP implants.
Friedl, Gerald; Radl, Roman; Stihsen, Christoph; Rehak, Peter; Aigner, Reingard; Windhager, Reinhard
2009-02-01
Aseptic loosening is the most frequent cause of implant failure in total hip arthroplasty. While a direct link between aseptic loosening and periprosthetic bone loss remains elusive, there is plentiful evidence for a close association with early implant migration. The present trial was primarily designed to evaluate whether a single infusion of 4 mg of zoledronic acid prevented early implant migration in patients with osteonecrosis of the femoral head. Fifty patients were consecutively enrolled to receive either zoledronic acid or saline solution after cementless total hip arthroplasty. Radiographs, biochemical parameters of bone turnover, and the Harris hip-rating score were determined preoperatively and at each follow-up examination at seven weeks, six months, one year, and yearly thereafter. The median follow-up period was 2.8 years. We found a significant subsidence of the stem of up to a mean (and standard deviation) of -1.2 +/- 0.6 mm at two years within the control group, and the cups had a mean medialization of 0.6 +/- 1.0 mm and a mean cranialization of 0.6 +/- 0.8 mm (p < 0.001). Treatment with zoledronic acid effectively minimized the migration of the cups in both the transverse and the vertical direction (mean, 0.15 +/- 0.6 mm and 0.06 +/- 0.6 mm, respectively; p < 0.05), while only a trend to decreased subsidence of the stem was detected. Finally, the Harris hip score rapidly increased over time in both treatment groups, although this increase was significantly more pronounced in the zoledronate-treated group than in the control group (analysis of variance, p = 0.008). A single infusion of zoledronic acid shows promise in improving initial fixation of a cementless implant, which may improve the clinical outcome of total hip arthroplasty in patients with osteonecrosis of the femoral head.
Yang, Hua-Wei; Tang, Xiao-Shan; Tian, Zhuo-Wei; Wang, Yang; Yang, Wen-Yi; Hu, Jing-Zhou
2017-09-25
BACKGROUND This study explored the effects of nano-hydroxyapatite/polyetheretherketone (n-HA/PEEK)- coated sandblasted, large-grit, and acid-etched (SLA) implants on inflammatory cytokines and osseointegration in peri-implantitis model beagle dogs. MATERIAL AND METHODS Peri-implantitis models were established. Eight beagle dogs were randomly and evenly assigned into SLA tied, SLA + n-HA/PEEK tied, SLA untied, or SLA + n-HA/PEEK untied groups. A special periodontal probe was used to detect the plaque index (PLI), probing depth (PD), and modified Sulcus Bleeding Index (mSBI). Gingival crevicular fluid was collected and an ELISA kit was utilized to detect IL-1, IL-6, and IL-17 levels. The colony-forming units were counted and the maximum shear strength of implants was tested using the axial pullout test. HE staining was used to detect the inflammation of peri-implant bone tissues. Osseointegration was observed through toluidine blue staining. Bone-to-implant contact (BIC) was obtained through histological observation and the mineral apposition rate (MAR) was calculated after immune fluorescent double staining. RESULTS The SLA tied group demonstrated higher levels of PLI, PD, mSBI, IL-1, IL-6, and IL-17 and a higher degree of inflammation than the SLA + n-HA/PEEK tied group. The tied groups also displayed similar results over the untied groups at the same time point. The maximum shear strength, BIC, and MAR in the SLA tied group were significantly lower than in the SLA + n-HA/PEEK tied group. CONCLUSIONS Our findings demonstrate that SLA + n-HA/PEEK implants can promote osseointegration and relieve the inflammation response of peri-implantitis in beagle dogs.
Gels as battery separators for soluble electrode cells
NASA Technical Reports Server (NTRS)
Sheibley, D. W.; Gahn, R. F. (Inventor)
1977-01-01
Gels are formed from silica powders and hydrochloric acid. The gels are then impregnated into a polymeric foam and the resultant sheet material is then used in applications where the transport of chloride ions is desired. Specifically disclosed is the utilization of the sheet in electrically rechargeable redox flow cells which find application in bulk power storage systems.
Ma, Ting; Ge, Xi-Yuan; Hao, Ke-Yi; Zhang, Bi-Ru; Jiang, Xi; Lin, Ye; Zhang, Yu
2017-12-19
Osteoporosis presents a challenge to the long-term success of osseointegration of endosseous implants. The bio-inspired 3,4-dihydroxy-L-phenylalanine (Dopa) coating is widely used as a basic layer to bind osteogenetic molecules that may improve osseointegration. To date, little attention has focused on application of Dopa alone or binding inhibitors of bone resorption in osteoporosis. Local use of a bisphosphonate such as zoledronic acid (ZA), an inhibitor of osteoclast-mediated bone resorption, has been proven to improve implant osseointegration. In this study, ovariectomized rats were divided into four groups and implanted with implants with different surface modifications: sandblasted and acid-etched (SLA), SLA modified with Dopa (SLA-Dopa), SLA modified with ZA (SLA-ZA), and SLA modified with Dopa and ZA (SLA-Dopa + ZA). Measurement of removal torque, micro-computed tomography and histology revealed a greater extent of bone formation around the three surface-modified implants than SLA-controls. No synergistic effect was observed for combined Dopa + ZA coating. Microarray analysis showed the Dopa coating inhibited expression of genes associated with osteoclast differentiation, similarly to the mechanism of action of ZA. Simple Dopa modification resulted in a similar improvement in osseointegration compared to ZA. Thus, our data suggest simple Dopa coating is promising strategy to promote osseointegration of implants in patients with osteoporosis.
Sun, Yu; Jensen, Henrik; Petersen, Nickolaj J; Larsen, Susan W; Østergaard, Jesper
2017-10-25
Phase separation of in situ forming poly (lactide-co-glycolide acid) (PLGA) implants with agarose hydrogels as the provider of nonsolvent (water) mimicking subcutaneous tissue was investigated using a novel UV-vis imaging-based analytical platform. In situ forming implants of PLGA-1-methyl-2-pyrrolidinone and PLGA-triacetin representing fast and slow phase separating systems, respectively, were evaluated using this platform. Upon contact with the agarose hydrogel, the phase separation of the systems was followed by the study of changes in light transmission and absorbance as a function of time and position. For the PLGA-1-methyl-2-pyrrolidinone system, the rate of spatial phase separation was determined and found to decrease with increasing the PLGA concentration from 20% to 40% (w/w). Hydrogels with different agarose concentrations (1% and 10% (w/v)) were prepared for providing the nonsolvent, water, to the in situ forming PLGA implants simulating the injection site environment. The resulting implant morphology depended on the stiffness of hydrogel matrix, indicating that the matrix in which implants are formed is of importance. Overall, the work showed that the UV-vis imaging-based platform with an agarose hydrogel mimicking the subcutaneous tissue holds potential in providing bio-relevant and mechanistic information on the phase separation processes of in situ forming implants. Copyright © 2017 Elsevier B.V. All rights reserved.
Rieger, Elisabeth; Dupret-Bories, Agnès; Salou, Laetitia; Metz-Boutigue, Marie-Helene; Layrolle, Pierre; Debry, Christian; Lavalle, Philippe; Vrana, Nihal Engin
2015-06-07
Porous titanium implants are widely employed in the orthopaedics field to ensure good bone fixation. Recently, the use of porous titanium implants has also been investigated in artificial larynx development in a clinical setting. Such uses necessitate a better understanding of the interaction of soft tissues with porous titanium structures. Moreover, surface treatments of titanium have been generally evaluated in planar structures, while the porous titanium implants have complex 3 dimensional (3D) architectures. In this study, the determining factors for soft tissue integration of 3D porous titanium implants were investigated as a function of surface treatments via quantification of the interaction of serum proteins and cells with single titanium microbeads (300-500 μm in diameter). Samples were either acid etched or nanostructured by anodization. When the samples are used in 3D configuration (porous titanium discs of 2 mm thickness) in vivo (in subcutis of rats for 2 weeks), a better integration was observed for both anodized and acid etched samples compared to the non-treated implants. If the implants were also pre-treated with rat serum before implantation, the integration was further facilitated. In order to understand the underlying reasons for this effect, human fibroblast cell culture tests under several conditions (directly on beads, beads in suspension, beads encapsulated in gelatin hydrogels) were conducted to mimic the different interactions of cells with Ti implants in vivo. Physical characterization showed that surface treatments increased hydrophilicity, protein adsorption and roughness. Surface treatments also resulted in improved adsorption of serum albumin which in turn facilitated the adsorption of other proteins such as apolipoprotein as quantified by protein sequencing. The cellular response to the beads showed considerable difference with respect to the cell culture configuration. When the titanium microbeads were entrapped in cell-laden gelatin hydrogels, significantly more cells migrated towards the acid etched beads. In conclusion, the nanoscale surface treatment of 3D porous titanium structures can modulate in vivo integration by the accumulative effect of the surface treatment on several physical factors such as protein adsorption, surface hydrophilicity and surface roughness. The improved protein adsorption capacity of the treated implants can be further exploited by a pre-treatment with autologous serum to render the implant surface more bioactive. Titanium microbeads are a good model system to observe these effects in a 3D microenvironment and provide a better representation of cellular responses in 3D.
Akkaya, Alper; Pazarlioglu, Nurdan
2013-01-01
Poly(3-hydroxybutyrate) is nontoxic and biodegradable, with good biocompatibility and potential support for long-term implants. For this reason, it is a good support for enzyme immobilization. Enzyme immobilization could not be done directly because poly(3-hydroxybutyrate) has no functional groups. Therefore, modification should be done for enzyme immobilization. In this study, methacrylic acid was graft polymerized to poly(3-hydroxybutyrate) and thrombin was immobilized to polymethacrylic acid grafted poly(3-hydroxybutyrate). In fact, graft polymerization of methacrylic acid to poly(3-hydroxybutyrate) and thrombin immobilization was a model study. Biomolecule immobilized poly(3-hydroxybutyrate) could be used as an implant. Thrombin was selected as a biomolecule for this model study and it was immobilized to methacrylic acid grafted poly(3-hydroxybutyrate). Then the developed product was used to stop bleeding.
Current applications of foams formed from mixed surfactant-polymer solutions.
Bureiko, Andrei; Trybala, Anna; Kovalchuk, Nina; Starov, Victor
2015-08-01
Foams cannot be generated without the use of special foaming agents, as pure liquids do not foam. The most common foaming agents are surfactants, however often for foam stability one active agent is not enough, it is necessary to add other component to increase foam lifetime. Foams on everyday use are mostly made from mixture of different components. Properly chosen combinations of two active ingredients lead to a faster foam formation and increased foam stability. During the last decade polymers (mainly polyelectrolytes and proteins) have become frequently used additives to foaming solutions. Mixtures of surfactants and polymers often demonstrate different foaming properties in comparison to surfactant only or polymer only solutions. The nature of surfactant-polymer interactions is complicated and prediction of resulting foaming properties of such formulations is not straightforward. Properties and foaming of surfactant-polymer mixtures are discussed as well as current applications of foams and foaming agents as foams are widely used in cosmetics, pharmaceutics, medicine and the food industry. Copyright © 2014 Elsevier B.V. All rights reserved.
Wang, Jin-song; Cao, Pin-lu; Yin, Kun
2015-07-01
Environmental, economical and efficient antifoaming technology is the basis for achievement of foam drilling fluid recycling. The present study designed a novel two-stage laval mechanical foam breaker that primarily uses vacuum generated by Coanda effect and Laval principle to break foam. Numerical simulation results showed that the value and distribution of negative pressure of two-stage laval foam breaker were larger than that of the normal foam breaker. Experimental results showed that foam-breaking efficiency of two-stage laval foam breaker was higher than that of normal foam breaker, when gas-to-liquid ratio and liquid flow rate changed. The foam-breaking efficiency of normal foam breaker decreased rapidly with increasing foam stability, whereas the two-stage laval foam breaker remained unchanged. Foam base fluid would be recycled using two-stage laval foam breaker, which would reduce the foam drilling cost sharply and waste disposals that adverse by affect the environment.
Acidification of uterine epithelium during embryo implantation in mice†
Xiao, Shuo; Li, Rong; El Zowalaty, Ahmed E.; Diao, Honglu; Zhao, Fei; Choi, Yongwon; Ye, Xiaoqin
2017-01-01
Abstract Uterine luminal epithelium (LE) is essential for establishing uterine receptivity. Previous microarray analysis revealed upregulation of Atp6v0d2 in gestation day 4.5 (D4.5) LE in mice. Realtime PCR showed upregulation of uterine Atp6v0d2 starting right before embryo attachment ∼D4.0. In situ hybridization demonstrated specific uterine localization of Atp6v0d2 in LE upon embryo implantation. Atp6v0d2 encodes one subunit for vacuolar-type H+-ATPase (V-ATPase), which regulates acidity of intracellular organelles and extracellular environment. LysoSensor Green DND-189 detected acidic signals in LE and glandular epithelium upon embryo implantation, correlating with Atp6v0d2 upregulation in early pregnant uterus. Atp6v0d2−/− females had significantly reduced implantation rate and marginally reduced delivery rate from first mating only, but comparable number of implantation sites and litter size compared to control and comparable fertility to control from subsequent matings, suggesting a nonessential role of Atp6v0d2 subunit in embryo implantation. Successful implantation in both control and Atp6v0d2−/− females was associated with uterine epithelial acidification. No significant compensatory upregulation of Atp6v0d1 mRNA was detected in D4.5 Atp6v0d2−/− uteri. To determine the role of V-ATPase instead of a single subunit in embryo implantation, a specific V-ATPase inhibitor bafilomycin A1 (2.5 μg/kg) was injected via uterine fat pad on D3 18:00 h. This treatment resulted in reduced uterine epithelial acidification, delayed implantation, and reduced number of implantation sites. It also suppressed oil-induced artificial decidualization. These data demonstrate uterine epithelial acidification as a novel phenomenon during embryo implantation and V-ATPase is involved in uterine epithelial acidification and uterine preparation for embryo implantation. PMID:28395338
Ohtake, Satoshi; Martin, Russell; Saxena, Atul; Pham, Binh; Chiueh, Gary; Osorio, Manuel; Kopecko, Dennis; Xu, DeQi; Lechuga-Ballesteros, David; Truong-Le, Vu
2011-01-01
Foam drying, a modified freeze drying process, was utilized to produce a heat-stable, live attenuated Salmonella Typhi ‘Ty21a’ bacterial vaccine. Ty21a vaccine was formulated with pharmaceutically approved stabilizers, including sugars, plasticizers, amino acids, and proteins. Growth media and harvesting conditions of the bacteria were also studied to enhance resistance to desiccation stress encountered during processing as well as subsequent storage at elevated temperatures. The optimized Ty21a vaccine, formulated with trehalose, methionine, and gelatin, demonstrated stability for approximately 12 weeks at 37°C (i.e., time required for the vaccine to decrease in potency by 1log10 CFU) and no loss in titer at 4 and 25°C following storage for the same duration. Furthermore, the foam dried Ty21a elicited a similar immunogenic response in mice as well as protection in challenge studies compared to Vivotif™, the commercial Ty21a vaccine. The enhanced heat stability of the Ty21a oral vaccine, or Ty21a derivatives expressing foreign antigens (e.g. anthrax), could mitigate risks of vaccine potency loss during long term storage, shipping, delivery to geographical areas with warmer climates or during emergency distribution following a bioterrorist attack. Because the foam drying process is conducted using conventional freeze dryers and can be readily implemented at any freeze drying manufacturing facility, this technology appears ready and appropriate for large scale processing of foam dried vaccines. PMID:21300096
Sánchez-Gárces, María Angeles; Gay-Escoda, Cosme
2004-01-01
Orodental rehabilitation through the use of implants offers very high success rates. In this paper, we describe some of the complications involved with this technique, such as periimplant disease and, within this category, periimplantitis, an inflammatory reaction in which there is a loss of the bony support of the implant accompanied by inflammation. The aetiology of the disease is conditioned by the status of the tissue surrounding the implant, implant design, degree of roughness, the poor alignment of implant components, external morphology and excessive mechanical load. The microorganisms most commonly associated with implant failure are spirochetes and mobile forms of Gram-negative anaerobes, unless the origin is the result of simple mechanical overload. Diagnosis is based on changes of colour in the gum, bleeding and probing depth of periimplant pockets, suppuration, x-ray and gradual loss of bone height around the tooth. Treatment will differ depending upon whether it is a case of mucositis or periimplantitis. Therapeutic objectives focus on correcting technical defects by means of surgery and decontamination techniques (abrasion with carbon particles, citric acid solution, topical tetracycline application and laser surgery). This study also presents a microbiological study of periimplantitis conducted by the Barcelona School of Dentistry that determined that the antibiotic therapy proven to be most efficacious in the antibiogram was the association of amoxycillin and clavulanic acid.
Fiorilli, Sonia; Baino, Francesco; Cauda, Valentina; Crepaldi, Marco; Vitale-Brovarone, Chiara; Demarchi, Danilo; Onida, Barbara
2015-01-01
In this work, the coating of 3-D foam-like glass-ceramic scaffolds with a bioactive mesoporous glass (MBG) was investigated. The starting scaffolds, based on a non-commercial silicate glass, were fabricated by the polymer sponge replica technique followed by sintering; then, electrophoretic deposition (EPD) was applied to deposit a MBG layer on the scaffold struts. EPD was also compared with other techniques (dipping and direct in situ gelation) and it was shown to lead to the most promising results. The scaffold pore structure was maintained after the MBG coating by EPD, as assessed by SEM and micro-CT. In vitro bioactivity of the scaffolds was assessed by immersion in simulated body fluid and subsequent evaluation of hydroxyapatite (HA) formation. The deposition of a MBG coating can be a smart strategy to impart bioactive properties to the scaffold, allowing the formation of nano-structured HA agglomerates within 48 h from immersion, which does not occur on uncoated scaffold surfaces. The mechanical properties of the scaffold do not vary after the EPD (compressive strength ~19 MPa, fracture energy ~1.2 × 10(6) J m(-3)) and suggest the suitability of the prepared highly bioactive constructs as bone tissue engineering implants for load-bearing applications.
Matin, Khalrul; Senpuku, Hidenobu; Hanada, Nobuhiro; Ozawa, Hidehiro; Ejiri, Sadakazu
2003-01-01
Difficulties relating to bone regeneration that complicate immediate implant placement include buccal and/or lingual fenestrations, primary anchorage of the implants, and the need for protection from functional loading during the osseointegration period. The objective of this pilot study was to evaluate bone regeneration by recombinant human bone morphogenetic protein-2 (rhBMP-2) around immediate implants placed in maxillary sockets in rats. A total of 16 cylindric 0.8 x 1.8-mm commercially pure, solid titanium Implants were placed immediately after gentle extraction of the maxillary first molar teeth of 8 male Wistar rats. The sockets were randomly divided into 3 groups: group 1 (n = 6) received rhBMP-2 with polylactic acid/polyglycolic acid copolymer-coated gelatin sponge carrier; group 2 (n = 5) received only the carrier; and group 3 (n = 5) received no grafting materials following placement The rats were euthanized at 90 days postsurgery for microscopic analysis. In group 1, the implant body remained submerged completely, including the coronal part, which was fully covered by a significant amount (30% of total height) of regenerated cortical bone, even though the implant could easily be pulled out by a tweezer at the time of placement. Close approximation between the implant surface and regenerated bone could also be detected, indicating good bone-to-implant contact. In contrast, only peri-implant bone regeneration occurred in group 2, and an approximate 0.3-mm coronal part of the implant remained exposed. When no grafting materials were used (group 3), almost one third of the total length of the implant was exfoliated out of the socket when no grafting materials were used. Based on previous study and data from 16 sockets of the present study, it could be concluded that rhBMP-2 facilitated the regeneration of bone around immediate implants. In particular, the bone covering the coronal part could have been regenerated shortly after surgery, which helped to maintain the implant body inside the socket during the integration period in rats.
NASA Astrophysics Data System (ADS)
Xue, Ping; Xu, Fang; Xu, Lidong
2008-12-01
The epoxy-functionalized mesoporous cellular foams (G-MCFs) with high specific surface area (˜400 m 2/g) and large-size mesopores (˜17 nm) were obtained by condensation of 3-glycidoxypropyltriethoxysilane (GPTS) and the surface silanol groups of mesoporous cellular foams (MCFs) and used as the support for immobilization of penicillin G acylase (PGA). The structural properties of G-MCF were characterized by FT-IR, N 2 adsorption, TG-DTA and 29Si MAS NMR. The studies indicated that the glycidoxypropyl groups were chemically bonded to the silicon atoms on the surface of MCF. The epoxy-functionalized mesoporous cellular foams can provide the microenvironments suitable for the immobilization of PGA, and the enzyme molecules could be immobilized covalently onto the G-MCF under mild conditions by reaction between the amino groups of the enzyme molecules and the epoxy groups on the surface of G-MCF. The PGA immobilized on G-MCF (PGA/G-MCF) exhibited the apparent activity of 1782 IU/g and 46.6% of activity recovery for hydrolyzing penicillin G potassium to produce 6-aminopenicillanic acid at 37 °C which were higher than that of PGA on pure silica MCF (1521 IU/g and 39.8%, respectively). The kinetic study also indicated that PGA immobilized on G-MCF has a Km of 2.1 × 10 -2 mol/L lower than that of PGA immobilized on the pure silica MCF (5.0 × 10 -2 mol/L). These may be attributed to the enhanced surface affinity between G-MCF support and the substrate molecules. Due to the covalent immobilization of PGA molecules on the surface of G-MCF, the immobilized PGA with considerable operational stability was achieved. The activity of PGA/G-MCF is still about 91.4% of its initial activity at the 10th cycle reuse while that of PGA/MCF only remains 41.5% of its initial activity at the same reuse numbers. In addition, the investigation results show the thermal stability and durability on acid or basic medium of PGA immobilized on G-MCF were improved remarkably.
Combe, Alexander L; Ang, Justin K; Bamforth, Charles W
2013-07-01
The foam stability of beer is dependent on the presence of foam-stabilizing polypeptides derived from the cereals from which it is made. It has long been argued that there is a tendency to boost the foam-stabilizing capabilities of these polypeptides at the heating stages involved in the production of the grist materials. The present study started with the intent to confirm whether these changes occurred and to assess the extent to which different cereal products differed in their foam-stabilizing tendencies. Cereal products differ enormously in their foam-stabilizing capabilities. Heavily roasted grains, notably black malt and roast barley, do have superior foaming properties. However, certain specialty malts, notably crystal malts, display inferior foam performance. The observed foaming pattern is a balance between their content of foam-positive and foam-negative components. Products such as pale malt do contain foam-negative materials but have a net balance in favour of foam-stabilizing entities. By contrast, wheat malt and especially black malt have a heavy preponderance of foam-positive components. Crystal malt displays the converse behaviour: it contains low-molecular-weight foam-negative species. Several of the cereal products appear to contain higher-molecular-weight foam inhibitors, but it appears that they are merely species that are of inherently inferior foam-stabilizing capability to the foaming polypeptides from egg white that were employed to probe the system. The foam-damaging species derived from crystal malt carried through to beers brewed from them. Intense heating in the production of cereal products does lead to enhanced foam performance in extracts of those products. However, not all speciality malts display superior foam performance, through their development of foam-negative species of lower molecular weight. © 2013 Society of Chemical Industry.
Xue, Bai-Liang; Wen, Jia-Long; Sun, Run-Cang
2015-02-10
Lignin-based polyols were synthesized through microwave-assisted liquefaction under different microwave heating times (5-30 min). The liquefaction reactions were carried out using polyethylene glycol (PEG-400)/glycerol as liquefying solvents and 97 wt% sulfur acid as a catalyst at 140 °C. The polyols obtained were analyzed for their yield, composition and structural characteristics using gel permeation chromatography (GPC), Fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectra. FT-IR and NMR spectra showed that the liquefying solvents reacted with the phenol hydroxyl groups of the lignin in the liquefied product. With increasing microwave heating time, the viscosity of polyols was slightly increased and their corresponding molecular weight ( M W ) was gradually reduced. The optimal condition at the microwave heating time (5 min) ensured a high liquefaction yield (97.47%) and polyol with a suitable hydroxyl number (8.628 mmol/g). Polyurethane (PU) foams were prepared by polyols and methylene diphenylene diisocyanate (MDI) using the one-shot method. With the isocyanate/hydroxyl group ([NCO]/[OH]) ratio increasing from 0.6 to 1.0, their mechanical properties were gradually increased. This study provided some insight into the microwave-assisted liquefied lignin polyols for the production of rigid PU foam.
NASA Astrophysics Data System (ADS)
Sahu, Sritam Swapnadarshi; Gandhi, Indu Siva Ranjani; Khwairakpam, Selija
2018-06-01
Foam concrete finds application in many areas, generally as a function of its relatively lightweight and its beneficial properties in terms of reduction in dead load on structure, excellent thermal insulation and contribution to energy conservation. For production of foam concrete with desired properties, stable and good quality foam is the key requirement. It is to be noted that the selection of surfactant and foam production parameters play a vital role in the properties of foam which in turn affects the properties of foam concrete. However, the literature available on the influence of characteristics of foaming agent and foam on the properties of foam concrete are rather limited. Hence, a more systematic research is needed in this direction. The focus of this work is to provide a review on characteristics of surfactant (foaming agent) and foam for use in foam concrete production.
NASA Astrophysics Data System (ADS)
Sahu, Sritam Swapnadarshi; Gandhi, Indu Siva Ranjani; Khwairakpam, Selija
2018-02-01
Foam concrete finds application in many areas, generally as a function of its relatively lightweight and its beneficial properties in terms of reduction in dead load on structure, excellent thermal insulation and contribution to energy conservation. For production of foam concrete with desired properties, stable and good quality foam is the key requirement. It is to be noted that the selection of surfactant and foam production parameters play a vital role in the properties of foam which in turn affects the properties of foam concrete. However, the literature available on the influence of characteristics of foaming agent and foam on the properties of foam concrete are rather limited. Hence, a more systematic research is needed in this direction. The focus of this work is to provide a review on characteristics of surfactant (foaming agent) and foam for use in foam concrete production.
Experimental Study of Hysteresis behavior of Foam Generation in Porous Media.
Kahrobaei, S; Vincent-Bonnieu, S; Farajzadeh, R
2017-08-21
Foam can be used for gas mobility control in different subsurface applications. The success of foam-injection process depends on foam-generation and propagation rate inside the porous medium. In some cases, foam properties depend on the history of the flow or concentration of the surfactant, i.e., the hysteresis effect. Foam may show hysteresis behavior by exhibiting multiple states at the same injection conditions, where coarse-textured foam is converted into strong foam with fine texture at a critical injection velocity or pressure gradient. This study aims to investigate the effects of injection velocity and surfactant concentration on foam generation and hysteresis behavior as a function of foam quality. We find that the transition from coarse-foam to strong-foam (i.e., the minimum pressure gradient for foam generation) is almost independent of flowrate, surfactant concentration, and foam quality. Moreover, the hysteresis behavior in foam generation occurs only at high-quality regimes and when the pressure gradient is below a certain value regardless of the total flow rate and surfactant concentration. We also observe that the rheological behavior of foam is strongly dependent on liquid velocity.
DE Colli, Marianna; Radunovic, Milena; Zizzari, Vincenzo L; DI Giacomo, Viviana; DI Nisio, Chiara; Piattelli, Adriano; Calvo Guirado, José L; Zavan, Barbara; Cataldi, Amelia; Zara, Susi
2018-03-30
Titanium surface modification is critical for dental implant success. Our aim was to determine surfaces influence on dental pulp stem cells (DPSCs) viability and differentiation. Implants were divided into sandblasted/acid-etched (control) and sandblasted/acid-etched coated with calcium and magnesium ions (CaMg), supplied as composite (test). Proliferation was evaluated by MTT, differentiation checking osteoblastic gene expression, PGE2 secretion and matrix formation, inflammation by Interleukin 6 (IL-6) detection. MTT and IL-6 do not modify on test. A PGE2 increase on test is recorded. BMP2 is higher on test at early experimental points, Osterix and RUNX2 augment later. Alizarin-red S reveals higher matrix production on test. These results suggest that test surface is more osteoinductive, representing a start point for in vivo studies aiming at the construction of more biocompatible dental implants, whose integration and clinical performance are improved and some undesired effects, such as implant stability loss and further surgical procedures, are reduced.
NASA Astrophysics Data System (ADS)
Izadi, M.; Kam, S.
2017-12-01
Scope: Numerous laboratory and field tests revealed that foam can effectively control gas mobility and improve sweep efficiency in enhanced-oil-recovery and subsurface-remediation processes, if correctly designed. The objective of this study is to answer (i) how mechanistic foam model parameters can be determined by fitting lab experiments in a step-by-step manner; (ii) how different levels of mobilization pressure gradient for foam generation affects the fundamentals of foam propagation; and (iii) how foam propagation distance can be estimated in the subsurface. This study for the first time shows why, and by how much, supercritical CO2 foams are advantaged over other types of foams such as N2 foam. Methods: First of all, by borrowing experimental data existing in the literature, this study shows how to capture mechanistic foam model parameters. The model, then, is applied to a wide range of mobilization pressure gradient to represent different types of foams that have been applied in the field (Note that supercritical CO2 foams exhibit much lower mobilization pressure compared to other types of foams (N2, steam, air, etc.). Finally, the model and parameters are used to evaluate different types of foam injection scenarios in order to predict how far foams can propagate with what properties in the field condition. Results and Conclusions: The results show that (i) the presence of three different foam states (strong, weak, intermediate) as well as two different strong-foam flow regimes (high-quality and low-quality regimes) plays a key role in model fit and field-scale propagation prediction and (ii) the importance of complex non-Newtonian foam rheology should not be underestimated. More specifically, this study finds that (i) supercritical CO2 foams can propagate a few hundreds of feet easily, which is a few orders of magnitude higher than other foams such as N2 foams; (ii) for dry foams (or, strong foams in the high-quality regime), the higher gas fractions the less foams travel, while for wet foams (or, strong foams in the low-quality regime) the distance is not sensitive to gas fraction; and (iii) the higher injection rates (or pressures), the farther foams propagate (this effect is much more pronounced for dry foams).
Ahmad, Muthanna; Grime, Geoffrey W
2013-04-01
Porous silicon (PS) has been prepared using a microwave-assisted hydrofluoric acid (HF) etching method from a silicon wafer pre-implanted with 5 MeV Cu ions. The use of microbeam proton-induced X-ray emission (micro-PIXE) and microbeam Rutherford backscattering techniques reveals for the first time the capability of these techniques for studying the formation of micropores. The porous structures observed from micro-PIXE imaging results are compared to scanning electron microscope images. It was observed that the implanted copper accumulates in the same location as the pores and that at high implanted dose the pores form large-scale patterns of lines and concentric circles. This is the first work demonstrating the use of microwave-assisted HF etching in the formation of PS.
The Evaluation of Foam Performance and Flooding Efficiency
NASA Astrophysics Data System (ADS)
Keliang, Wang; Yuhao, Chen; Gang, Wang; Gen, Li
2017-12-01
ROSS-Miles and spinning drop interfacial tensionmeter are used to select suitable foam system through foam composite index (FCI) and interfacial tension (IT). The selected foam system are taken to conduct further test. The further tests are evaluating the foam system resistance to adsorption with multi-round core flooding dynamic adsorption test and evaluating the performance of foam system with four kinds of different transport distance, quantitatively analyzing the foam system effective distance after dynamic adsorption. The result shows that the foaming ability and the mobilizing ability of the foam system decrease with the increase of the round of dynamic adsorption. As the transport distance increases, the foaming ability and the mobilizing ability of the foam system decrease. This result further reveals the flooding characteristics of nitrogen foam flooding, which provides a reference for the implementation of nitrogen foam flooding technology.
Identification of the source of PFOS and PFOA contamination at a military air base site.
Arias E, Victor A; Mallavarapu, Megharaj; Naidu, Ravi
2015-01-01
Although the use of perfluorooctane sulfonic acid (PFOS)/perfluorooctanoic acid (PFOA)-based aqueous fire-fighting foams (AFFF) has been banned due to their persistence, bioaccumulation and toxicity to biota, PFOS and PFOA are still present at significant levels in the environment due to their past usage. This study investigated the reasons for detection of PFOS and PFOA in an evaporation pond used to collect the wastewater arising from fire-fighting exercises at a military air base despite the replacement of PFOS/PFOA-based foam with no PFOS/PFOA-foam about 6 years ago. Concentrations in the wastewater stored in this pond ranged from 3.6 to 9.7 mg/L for PFOS and between 0.6 and 1.7 mg/L for PFOA. The hypothesis tested in a laboratory study was that PFOS and PFOA have accumulated in the sediments of the pond and can be released into the main body of the water. Concentrations detected in the sediments were 38 and 0.3 mg/g for PFOS and PFOA, respectively. These values exceed the recently reported average global values for sediments (0.2-3.8 ng/g for PFOS and from 0.1 to 0.6 ng/g for PFOA) by a factor of several thousands. PFOS and PFOA distribution coefficients were derived for the organic content of the pond sediment (1.6%). Identification of the source of contamination and knowledge of the partition between soil and aqueous phases are vital first steps in developing a sustainable remediation technology to remove the source from the site. This study clearly suggests that unless the sediment is cleaned of PFOS/PFOA, these chemicals will continue to be detected for a long period in the pond water, with potential adverse impacts on the ecosystem.
Matthäus, Christian; Krafft, Christoph; Dietzek, Benjamin; Brehm, Bernhard R; Lorkowski, Stefan; Popp, Jürgen
2012-10-16
Monocyte-derived macrophages play a key role in atherogenesis because their transformation into foam cells is responsible for deposition of lipids in plaques within arterial walls. The appearance of cytosolic lipid droplets is a hallmark of macrophage foam cell formation, and the molecular basics involved in this process are not well understood. Of particular interest is the intracellular fate of different individual lipid species, such as fatty acids or cholesterol. Here, we utilize Raman microscopy to image the metabolism of such lipids and to trace their subsequent storage patterns. The combination of microscopic information with Raman spectroscopy provides a powerful molecular imaging method, which allows visualization at the diffraction limit of the employed laser light and biochemical characterization through associated spectral information. In order to distinguish the molecules of interest from other naturally occurring lipids spectroscopically, deuterium labels were introduced. Intracellular distribution and metabolic changes were observed for serum albumin-complexed palmitic and oleic acid and cholesterol and quantitatively evaluated by monitoring the increase in CD scattering intensities at 0.5, 1, 3, 6, 24, 30, and 36 h. This approach may also allow for investigating the cellular trafficking of other molecules, such as nutrients, metabolites, and drugs.
Kircik, Leon H; Gwazdauskas, Jennifer; Butners, Victoria; Eastern, Joseph; Green, Lawrence J
2013-03-01
Benzoyl peroxide (BPO) is a widely used over-the-counter (OTC) topical acne treatment often used in combination with salicylic acid (SA) to achieve better comedone control than that achieved with BPO alone. MaxClarity™ is an OTC acne treatment system comprising BPO and SA in an aqueous foam delivery vehicle, VersaFoam AF™. This paper describes 2 open-label, single-arm studies conducted to assess the efficacy, safety, tolerability, and patient preference of MaxClarity in the treatment of mild, moderate, and severe acne. Subjects applied MaxClarity twice daily for 8 weeks in study 402 and for 12 weeks in study 405. Reductions in all lesion types were seen throughout both studies. At week 8 (study 402), there was a mean reduction from baseline of -56.9 ± 32.7% in total lesions in subjects with mild, moderate, or severe acne. At week 12 (study 405), there was a reduction from baseline of -61.6 ± 22.0% in total lesions in subjects with moderate or severe acne. Overall, both studies demonstrated that MaxClarity is a generally well tolerated and effective treatment for mild, moderate, and severe acne.
Space Environmentally Durable Polyimides and Copolyimides
NASA Technical Reports Server (NTRS)
Connell, John W. (Inventor); Smith, Joseph G. (Inventor); Hergenrother, Paul M. (Inventor); Watson, Kent A. (Inventor); Thompson, Craig M. (Inventor)
2006-01-01
Polyimides displaying low color in thin films, atomic oxygen resistance, vacuum ultraviolet radiation resistance, solubility in organic solvents in the imide form, high glass transition (T(sub g)) temperatures, and high thermal stability are provided. The poly(amide acid)s, copoly(amide acid)s, polyimides and copolyimides are prepared by the reaction of stoichiometric ratios of an aromatic &anhydride with diamines which contain phenylphosphine oxide groups in polar aprotic solvents. Controlled molecular weight oligomeric (amide acid)s and imides can be prepared by offsetting the stoichiometry according to the Carothers equation using excess diamine and endcapping with aromatic anhydrides. The polyimide materials can be processed into various material forms such as thin films, fibers, foams, threads, adhesive film, coatings, dry powders, and fiber coated prepreg, and uses include thin film membranes on antennas, second-surface mirrors, thermal optical coatings, and multilayer thermal insulation (MLI) blanket materials.
Space Environmentally Durable Polyimides and Copolyimides
NASA Technical Reports Server (NTRS)
Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor); Watson, Kent A. (Inventor); Thompson, Craig M. (Inventor)
2005-01-01
Polyimides displaying low color in thin films, atomic oxygen resistance, vacuum ultraviolet radiation resistance, solubility in organic solvents in the imide form, high glass transition (T(sub g)) temperatures, and high thermal stability are provided. The poly(amide acid)s, copoly(amide acid)s, polyimides and copolyimides are prepared by the reaction of stoichiometric ratios of an aromatic dianhydride with diamines which contain phenylphosphine oxide groups in polar aprotic solvents. Controlled molecular weight oligomeric (amide acid)s and imides can be prepared by offsetting the stoichiometry according to the Carothers equation using excess diamine and endcapping with aromatic anhydrides The polyimide materials can be processed into various material forms such as thin films, fibers, foams, threads, adhesive film, coatings, dry powders, and fiber coated prepreg, and uses include thin film membranes on antennas, second-surface mirrors, thermal optical coatings, and multilayer thermal insulation (MLI) blanket materials.
Kotsakis, Georgios A; Lan, Caixia; Barbosa, Joao; Lill, Krista; Chen, Ruoqiong; Rudney, Joel; Aparicio, Conrado
2016-07-01
Chemotherapeutic agents (ChAs) are considered an integral part of current treatment protocols for the decontamination of titanium implants with peri-implantitis, based on their antimicrobial effect. Despite the proven antimicrobial effect of ChAs on titanium-bound biofilms, previous studies have elucidated an unexpected disassociation between bacterial reduction and biologically acceptable treatment outcomes. In this study, the authors hypothesize that ChAs residues alter titanium physicochemistry and thus compromise cellular response to decontaminated surfaces. Grit-blasted acid-etched titanium disks were contaminated with multispecies microcosm biofilms grown from in vivo peri-implant plaque samples. To simulate implant decontamination, the contaminated disks were burnished with 0.12% chlorhexidine, 20% citric acid, 24% EDTA/1.5% NaOCl, or sterile saline and assessed surface physicochemical properties. Sterile untreated surfaces were the controls. The biologic effects of decontamination were assessed via cell proliferation and differentiation assays. Bacterial counts after decontamination confirmed that the ChAs were antimicrobial. X-ray photoelectron spectroscopy invariably detected elemental contaminants associated with each ChA molecule or salt that significantly altered wettability compared with controls. Notably, all surfaces with ChA residues showed some cytotoxic effect compared with controls (P <0.05). Increased cell counts were consistently found in the saline-treated group compared with chlorhexidine (P = 0.03). Interestingly, no association was found between antimicrobial effect and cell counts (P >0.05). ChA-specific residues left on the titanium surfaces altered titanium physical properties and adversely affected the osteoblastic response irrespective of their observed antimicrobial effect. Chlorhexidine may compromise the biocompatibility of titanium surfaces, and its use is not recommended to detoxify implants. Sterile saline, citric acid, and NaOCl-EDTA may be proposed for use in the treatment of peri-implantitis. Contrary to previous studies that recommended the selection of ChAs for the decontamination of titanium implants according to their antimicrobial effects, the present study demonstrated that the restoration of the biocompatibility of contaminated titanium surfaces is also contingent on the preservation of titanium material properties.
Chang, Mun Young; Gwon, Tae Mok; Lee, Ho Sun; Lee, Jun Ho; Oh, Seung Ha; Kim, Sung June; Park, Min-Hyun
2017-03-15
The present study aimed to evaluate the effects of systemic lipoic acid on hearing preservation after cochlear implantation. Twelve Dunkin-Hartley guinea pigs were randomly divided into two groups: the control group and the lipoic acid group. Animals in the lipoic acid group received lipoic acid intraperitoneally for 4 weeks. A sterilised silicone electrode-dummy was inserted through the round window to a depth of approximately 5 mm. The hearing level was measured using auditory brainstem responses (ABRs) prior to electrode-dummy insertion, and at 4 days and 1, 2, 3 and 4 weeks after electrode-dummy insertion. The threshold shift was defined as the difference between the pre-operative threshold and each of the post-operative thresholds. The cochleae were examined histologically 4 weeks after electrode-dummy insertion. Threshold shifts changed with frequency but not time. At 2kHz, ABR threshold shifts were statistically significantly lower in the lipoic acid group than the control group. At 8, 16 and 32kHz, there was no significant difference in the ABR threshold shift between the two groups. Histologic review revealed less intracochlear fibrosis along the electrode-dummy insertion site in the lipoic acid group than in the control group. The spiral ganglion cell densities of the basal, middle and apical turns were significantly higher in the lipoic acid group compared with the control group. Therefore, systemic lipoic acid administration appears to effectively preserve hearing at low frequencies in patients undergoing cochlear implantation. These effects may be attributed to the protection of spiral ganglion cells and prevention of intracochlear fibrosis. Copyright © 2017 Elsevier B.V. All rights reserved.
Zawaski, Janice A; Sabek, Omaima M; Voicu, Horatiu; Eastwood Leung, Hon-Chiu; Gaber, M Waleed
2017-11-15
Radiation therapy (RT) causes functional and transcriptomic changes in the brain; however, most studies have been carried out in normal rodent brains. Here, the long-term effect of irradiation and tumor presence during radiation was investigated. Male Wistar rats ∼7 weeks old were divided into 3 groups: sham implant, RT+sham implant, and RT+tumor implant (C6 glioma). Hypofractionated irradiation (8 or 6 Gy/day for 5 days) was localized to a 1-cm strip of cranium starting 5 days after implantation, resulting in complete tumor regression and prolonged survival. Biopsy of tissue was performed in the implant area 65 days after implantation. RNA was hybridized to GeneChip Rat Exon 1.0 ST array. Data were analyzed using significant analysis of microarrays and ingenuity pathway analysis. 1 H magnetic resonance spectroscopy ( 1 H-MRS) imaging was performed in the implantation site 65 to 70 days after implantation using a 9.4 T Biospec magnetic resonance imaging scanner with a quadrature rat brain array. Immunohistochemical staining for astrogliosis, HMG-CoA synthase 2, γ-aminobutyric acid (GABA) and taurine was performed at ∼65 days after implantation. Eighty-four genes had a false discovery rate <3.5%. We compared RT+tumor implant with RT+sham implant animals. The tumor presence affected networks associated with cancer/cell morphology/tissue morphology. 1 H-MRS showed significant reduction in taurine levels (P<.04) at the implantation site in both groups. However, the RT+tumor group also showed significant increase in levels of neurotransmitter GABA (P=.02). Hippocampal taurine levels were only significantly reduced in the RT+tumor group (P=.03). HMG-CoA synthase 2, GABA and taurine levels were confirmed using staining. Glial fibrillary acidic protein staining demonstrated a significant increase in inflammation that was heightened in the RT+tumor group. Our data indicate that tumor presence during radiation significantly affects long-term functional transcriptomics landscape and neurotransmitter levels at the tumor implantation site/normal tissue, accompanied by increased inflammation (astrogliosis). Copyright © 2017 Elsevier Inc. All rights reserved.
Analysis of risk factors for cluster behavior of dental implant failures.
Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann
2017-08-01
Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.
Madi, Marwa; Zakaria, Osama; Ichinose, Shizuko; Kasugai, Shohei
2016-02-01
The aim of this study was to compare the effect of ligature-induced periimplantitis on dental implants with and without hydroxyapatite (HA) coat. Thirty-two dental implants (3.3 mm wide, 13 mm long) with 4 surface treatments (8 implant/group) (M: machined, SA: sandblasted acid etched, S: sputter HA coat and P: plasma-sprayed HA coat) were inserted into canine mandibles. After 12 weeks, oral hygiene procedures were stopped and silk ligatures were placed around the implant abutments to allow plaque accumulation for the following 16 weeks. Implants with the surrounding tissues were retrieved and prepared for histological examination. Bone-to-implant contact (BIC) and implant surfaces were examined using scanning electron microscopy and energy dispersive x-ray spectroscopy. Histological observation revealed marginal bone loss and large inflammatory cell infiltrates in the periimplant soft tissue. Sputter HA implants showed the largest BIC (98.1%) and machined implant showed the smallest values (70.4%). After 28 weeks, thin sputter HA coat was almost completely dissolved, whereas plasma-sprayed HA coat showed complete thickness preservation. Thin sputter HA-coated implants showed more bone implant contact and less marginal bone loss than thick HA-coated implants under periimplantitis condition.
Prokop, A; Kozlov, E; Nun Non, S; Dikov, M M; Sephel, G C; Whitsitt, J S; Davidson, J M
2001-01-01
We seek to improve existing methodologies for allogenic grafting of pancreatic islets. The lack of success of encapsulated transplanted islets inside the peritoneal cavity is presently attributed to poor vascularization of the implant. A thick, fibrotic capsule often surrounds the graft, limiting survival. We have tested the hypothesis that neovascularization of the graft material can be induced by the addition of proper angiogenic factors embedded within a polymeric coat. Biocompatible and nonresorbable meshes coated with hydrophilic polymers were implanted in rats and harvested after 1-, 6-, and 12-week intervals. The implant response was assessed by histological observations on the degree of vascularity, fibrosis, and inflammation. Macrostructural geometry of meshes was conducive to tissue ingrowth into the interstitial space between the mesh filaments. Hydrogel coating with incorporated acidic or basic FGF in an electrostatic complex with polyelectrolytes and/or with heparin provided a sustained slow release of the angiogenic growth factor. Anti-factor VIII and anti-collagen type IV antibodies and a GSL I-B4 lectin were used to measure the extent of vascularization. Vigorous and persistent vascularization radiated several hundred microns from the implant. The level of vascularization should provide a sufficient diffusion of nutrients and oxygen to implanted islets. Based on our observations, stable vascularization may require a sustained angiogenic signal to allow for the development of a permanent implant structure.
Organic pollutant loading and biodegradability of firefighting foam
NASA Astrophysics Data System (ADS)
Zhang, Xian-Zhong; Bao, Zhi-ming; Hu, Cheng; Li-Shuai, Jing; Chen, Yang
2017-11-01
Firefighting foam has been widely used as the high-performance extinguishing agent in extinguishing the liquid poor fire. It was concerned for its environmental impacts due to its massive usage. In this study, the organic loading level and the biodegradability of 18 firefighting foams commonly used in China were evaluated and compared. The COD and TOC of firefighting foam concentrates are extremely high. Furthermore, those of foam solutions are also much higher than regular wastewater. The COD/TOC ratio of synthetic foams are higher than protein foams. The 28-day biodegradation rates of 18 firefighting foams are all over 60%, indicating that they are all ready biodegradable. Protein foams (P, FP and FFFP) have the higher organic loading and lower 28-day biodegradation rates compared to the synthetic foams (Class A foam, AFFF and S). The short and long-term impact of protein foams on the environment are larger than synthetic foams.
[Acetylsalicylic acid desensitization in the new era of percutaneous coronary intervention].
Fuertes Ferre, Georgina; Ferrer Gracia, Maria Cruz; Calvo Cebollero, Isabel
2015-09-21
Dual antiplatelet therapy is essential in patients undergoing percutaneous coronary intervention with stent implantation. Hypersensitivity to acetylsalicylic acid (ASA) limits treatment options. Desensitization to ASA has classically been studied in patients with respiratory tract disease. Over the last years, many protocols have been described about ASA desensitization in patients with ischemic heart disease, including acute coronary syndrome and the need for coronary stent implantation. It is important to know the efficacy and safety of ASA desensitization in these patients. Copyright © 2014 Elsevier España, S.L.U. All rights reserved.
Di Stefano, Danilo Alessio; Arosio, Paolo
2016-01-01
Bone density at implant placement sites is one of the key factors affecting implant primary stability, which is a determinant for implant osseointegration and rehabilitation success. Site-specific bone density assessment is, therefore, of paramount importance. Recently, an implant micromotor endowed with an instantaneous torque-measuring system has been introduced. The aim of this study was to assess the reliability of this system. Five blocks with different densities (0.16, 0.26, 0.33, 0.49, and 0.65 g/cm(3)) were used. A single trained operator measured the density of one of them (0.33 g/cm(3)), by means of five different devices (20 measurements/device). The five resulting datasets were analyzed through the analysis of variance (ANOVA) model to investigate interdevice variability. As differences were not significant (P = .41), the five devices were each assigned to a different operator, who collected 20 density measurements for each block, both under irrigation (I) and without irrigation (NI). Measurements were pooled and averaged for each block, and their correlation with the actual block-density values was investigated using linear regression analysis. The possible effect of irrigation on density measurement was additionally assessed. Different devices provided reproducible, homogenous results. No significant interoperator variability was observed. Within the physiologic range of densities (> 0.30 g/cm(3)), the linear regression analysis showed a significant linear correlation between the mean torque measurements and the actual bone densities under both drilling conditions (r = 0.990 [I], r = 0.999 [NI]). Calibration lines were drawn under both conditions. Values collected under irrigation were lower than those collected without irrigation at all densities. The NI/I mean torque ratio was shown to decrease linearly with density (r = 0.998). The mean error introduced by the device-operator system was less than 10% in the range of normal jawbone density. Measurements performed with the device were linearly correlated with the blocks' bone densities. The results validate the device as an objective intraoperative tool for bone-density assessment that may contribute to proper jawbone-density evaluation and implant-insertion planning.
A review of aqueous foam in microscale.
Anazadehsayed, Abdolhamid; Rezaee, Nastaran; Naser, Jamal; Nguyen, Anh V
2018-06-01
In recent years, significant progress has been achieved in the study of aqueous foams. Having said this, a better understanding of foam physics requires a deeper and profound study of foam elements. This paper reviews the studies in the microscale of aqueous foams. The elements of aqueous foams are interior Plateau borders, exterior Plateau borders, nodes, and films. Furthermore, these elements' contribution to the drainage of foam and hydraulic resistance are studied. The Marangoni phenomena that can happen in aqueous foams are listed as Marangoni recirculation in the transition region, Marangoni-driven flow from Plateau border towards the film in the foam fractionation process, and Marangoni flow caused by exposure of foam containing photosurfactants under UV. Then, the flow analysis of combined elements of foam such as PB-film along with Marangoni flow and PB-node are studied. Next, we contrast the behavior of foams in different conditions. These various conditions can be perturbation in the foam structure caused by injected water droplets or waves or using a non-Newtonian fluid to make the foam. Further review is about the effect of oil droplets and particles on the characteristics of foam such as drainage, stability and interfacial mobility. Copyright © 2018 Elsevier B.V. All rights reserved.
Innovative test method for the estimation of the foaming tendency of substrates for biogas plants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moeller, Lucie, E-mail: lucie.moeller@ufz.de; Eismann, Frank, E-mail: info@antoc.de; Wißmann, Daniel, E-mail: d.s.wissmann@gmx.de
2015-07-15
Graphical abstract: Display Omitted - Highlights: • Foaming in biogas plants depends on the interactions between substrate and digestate. • Foaming tests enable the evaluation of substrate foaming tendency in biogas plants. • Leipzig foam tester enables foaming tests of substrates prior to use. - Abstract: Excessive foaming in anaerobic digestion occurs at many biogas plants and can cause problems including plugged gas pipes. Unfortunately, the majority of biogas plant operators are unable to identify the causes of foaming in their biogas reactor. The occurrence of foaming is often related to the chemical composition of substrates fed to the reactor.more » The consistency of the digestate itself is also a crucial part of the foam formation process. Thus, no specific recommendations concerning substrates can be given in order to prevent foam formation in biogas plants. The safest way to avoid foaming is to test the foaming tendency of substrates on-site. A possible solution is offered by an innovative foaming test. With the help of this tool, biogas plant operators can evaluate the foaming disposition of new substrates prior to use in order to adjust the composition of substrate mixes.« less
Development of Defoamers for Confinenment Foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoffman, D M; Mitchell, A R
Aqueous foam concentrate (AFC) 380 foam was developed by Sandia National Laboratory as a blast mitigation foam for unexploded ordnance (UXO) and its ''engineered foam structure'' is reported to be able to ''envelop chemical or biological aerosols'' [1]. It is similar to commercial fire-fighting foams, consisting mostly of water with small amounts of two alcohols, an ether and surfactant. It also contains xanthan gum, probably, to strengthen the foam film and delay drainage. The concentrate is normally diluted in a 6:94 ratio with water for foaming applications. The diluted solution is normally foamed with air to an expansion factor ofmore » about 100 (density 0.01 g/cc), which is called ''dry'' foam. Higher density foam (0.18 > {rho} > 0.03 g/cc) was discovered which had quite different characteristics from ''dry'' foam and was called ''wet'' foam. Some characterization of these foams has also been carried out, but the major effort described in this document is the evaluation, at the small and medium scale, of chemical, mechanical and thermal approaches to defoaming AFC 380 foam. Several chemical approaches to defoaming were evaluated including oxidation and precipitation of the xanthan, use of commercial oil-emulsion or suspension defoamers, pH modification, and cation exchange with the surfactant. Of these the commercial defoamers were most effective. Two mechanical approaches to defoaming were evaluated: pressure and foam rupture with very fine particles. Pressure and vacuum techniques were considered too difficult for field applications but high surface area silica particles worked very well on dry foam. Finally simple thermal techniques were evaluated. An order-disorder transition occurs in xanthan solutions at about 60 C, which may be responsible for the effectiveness of hot air as a defoamer. During defoaming of 55 gallons of foam with hot air, after about 70% of the AFC 380 foam had been defoamed, the effectiveness of hot air was dramatically reduced. Approximately 15 gal of residual foam containing mostly small bubbles was resistant to further defoaming by methods that had been effective on the original, dry foam. In this paper the residual foam is referred to as ''wet'' and the original foam is referred to as ''dry''. Methods for generating ''wet'' foam in small to moderate quantities for defoaming experiments have been developed. Methods for defoaming wet foam are currently under study.« less
40 CFR 63.8830 - What definitions apply to this subpart?
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...
40 CFR 63.8830 - What definitions apply to this subpart?
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...
40 CFR 63.8830 - What definitions apply to this subpart?
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...
40 CFR 63.8830 - What definitions apply to this subpart?
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...
40 CFR 63.8830 - What definitions apply to this subpart?
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) National Emission Standards for Hazardous Air Pollutants: Flexible Polyurethane Foam Fabrication... chemical substance that is applied for the purpose of bonding foam to foam, foam to fabric, or foam to any... means the process of bonding flexible foam to one or more layers of material by heating the foam surface...
Maruta, Michito; Matsuya, Shigeki; Nakamura, Seiji; Ishikawa, Kunio
2011-01-01
Carbonate apatite (CO(3)Ap) foam may be an ideal bone substitute as it is sidelined to cancellous bone with respect to its chemical composition and structure. However, CO(3)Ap foam fabricated using α-tricalcium phosphate foam showed limited mechanical strength. In the present study, feasibility of the fabrication of calcite which could be a precursor of CO(3)Ap was studied. Calcite foam was successfully fabricated by the so-called "ceramic foam" method using calcium hydroxide coated polyurethane foam under CO(2)+O(2) atmosphere. Then the calcite foam was immersed in Na(2)HPO(4) aqueous solution for phase transformation based on dissolution-precipitation reaction. When CaO-free calcite foam was immersed in Na(2)HPO(4) solution, low-crystalline CO(3)Ap foam with 93-96% porosity and fully interconnected porous structure was fabricated. The compressive strength of the foam was 25.6 ± 6 kPa. In light of these results, we concluded that the properties of the precursor foam were key factors for the fabrication of CO(3)Ap foams.
NASA Astrophysics Data System (ADS)
Ari-Wahjoedi, Bambang; Ginta, Turnad Lenggo; Parman, Setyamartana; Abustaman, Mohd Zikri Ahmad
2014-10-01
Multicellular monolithic ceramic body is a ceramic material which has many gas or liquid passages partitioned by thin walls throughout the bulk material. There are many currently known advanced industrial applications of multicellular ceramics structures i.e. as supports for various catalysts, electrode support structure for solid oxide fuel cells, refractories, electric/electronic materials, aerospace vehicle re-entry heat shields and biomaterials for dental as well as orthopaedic implants by naming only a few. Multicellular ceramic bodies are usually made of ceramic phases such as mullite, cordierite, aluminum titanate or pure oxides such as silica, zirconia and alumina. What make alumina ceramics is excellent for the above functions are the intrinsic properties of alumina which are hard, wear resistant, excellent dielectric properties, resists strong acid and alkali attacks at elevated temperatures, good thermal conductivities, high strength and stiffness as well as biocompatible. In this work the processing technology leading to truly multicellular monolithic alumina ceramic bodies and their characterization are reported. Ceramic slip with 66 wt.% solid loading was found to be optimum as impregnant to the polyurethane foam template. Mullitic ceramic composite of alumina-sodium alumino disilicate-Leucite-like phases with bulk and true densities of 0.852 and 1.241 g cm-3 respectively, pore linear density of ±35 cm-1, linear and bulk volume shrinkages of 7-16% and 32 vol.% were obtained. The compressive strength and elastic modulus of the bioceramics are ≈0.5-1.0 and ≈20 MPa respectively.
Method of electroplating a conversion electron emitting source on implant
Srivastava, Suresh C [Setauket, NY; Gonzales, Gilbert R [New York, NY; Adzic, Radoslav [East Setauket, NY; Meinken, George E [Middle Island, NY
2012-02-14
Methods for preparing an implant coated with a conversion electron emitting source (CEES) are disclosed. The typical method includes cleaning the surface of the implant; placing the implant in an activating solution comprising hydrochloric acid to activate the surface; reducing the surface by H.sub.2 evolution in H.sub.2SO.sub.4 solution; and placing the implant in an electroplating solution that includes ions of the CEES, HCl, H.sub.2SO.sub.4, and resorcinol, gelatin, or a combination thereof. Alternatively, before tin plating, a seed layer is formed on the surface. The electroplated CEES coating can be further protected and stabilized by annealing in a heated oven, by passivation, or by being covered with a protective film. The invention also relates to a holding device for holding an implant, wherein the device selectively prevents electrodeposition on the portions of the implant contacting the device.
Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus
Jody, Bassam; Daniels, Edward; Libera, Joseph A.
1999-01-01
A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam.
Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus
Jody, B.; Daniels, E.; Libera, J.A.
1999-03-16
A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam. 4 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, M.L.; Carroll, H.A.
1986-07-01
The handbook describes basic types of foams that may be used to control vapor hazards from spilled volatile chemicals. It provides a table to be used by spill-response personnel to choose an appropriate foam based on the type of chemical spill. Six general types of foams, surfactant (syndet) foams, aqueous film forming foams (AFFF), alcohol type or polar solvent type foams (ATF), and special foams such as Hazmat NF no. 1 which was developed especially for alkaline spills. The handbook provides the basis for spill responders to evaluate and select a foam for vapor control by using the test methodsmore » presented or by considering manufacturers specifications for foam-expansion ratios and quarter drainage times. The responder is encouraged to maximize the effectiveness of a foam by trying different nozzles, distances of applications, and thicknesses of the foam layers.« less
Multilayer porous UHMWPE scaffolds for bone defects replacement.
Maksimkin, A V; Senatov, F S; Anisimova, N Yu; Kiselevskiy, M V; Zalepugin, D Yu; Chernyshova, I V; Tilkunova, N A; Kaloshkin, S D
2017-04-01
Reconstruction of the structural integrity of the damaged bone tissue is an urgent problem. UHMWPE may be potentially used for the manufacture of porous implants simulating as closely as possible the porous cancellous bone tissue. But the extremely high molecular weight of the polymer does not allow using traditional methods of foaming. Porous and multilayer UHMWPE scaffolds with nonporous bulk layer and porous layer that mimics cancellous bone architecture were obtained by solid-state mixing, thermopressing and washing in subcritical water. Structural and mechanical properties of the samples were studied. Porous UHMWPE samples were also studied in vitro and in vivo. The pores of UHMWPE scaffold are open and interconnected. Volume porosity of the obtained samples was 79±2%; the pore size range was 80-700μm. Strong connection of the two layers in multilayer UHMWPE scaffolds was observed with decreased number of fusion defects. Functionality of implants based on multilayer UHMWPE scaffolds is provided by the fixation of scaffolds in the bone defect through ingrowths of the connective tissue into the pores, which ensures the maintenance of the animals' mobility. Copyright © 2016 Elsevier B.V. All rights reserved.
Chevalier, E; Viana, M; Cazalbou, S; Chulia, D
2009-10-01
Calcium phosphate porous ceramics present a great interest not only as complex bone defect fillers but also as drug delivery systems. Most of the methods described in the literature to fabricate pellets are based on compaction, casting into spherical molds, or on processes such as liquid immiscibility or foaming. Despite wet granulation is used in a wide range of applications in pharmaceuticals, food, detergents, fertilizers, and minerals, it is not applied in the biomaterial field to produce granules. In this study physicochemical and in vitro drug delivery properties of implantable calcium phosphate granules, produced by two wet agglomeration processes, were compared. Pellets obtained by high shear granulation (granulation in a Mi-Pro apparatus) were shown to be more spherical and less friable than granules elaborated by low shear process (granulation in a Kenwood apparatus). Although Mi-Pro pellets had a slightly lower porosity compared to Kenwood granules, ibuprofen loading efficiency and dissolution profiles were not statistically different and the release mechanism was mainly controlled by diffusion, in both cases. Mi-Pro pellets appeared to be better candidates as bone defect fillers and local drug delivery systems as far as they were more spherical and less friable than Kenwood agglomerates.
Svanedal, Ida; Boija, Susanne; Norgren, Magnus; Edlund, Håkan
2014-06-10
The correlation between interaction parameters and ion flotation efficiency in mixtures of chelating surfactant metal complexes and different foaming agents was investigated. We have recently shown that chelating surfactant 2-dodecyldiethylenetriaminepentaacetic acid (4-C12-DTPA) forms strong coordination complexes with divalent metal ions, and this can be utilized in ion flotation. Interaction parameters for mixed micelles and mixed monolayer formation for Mg(2+) and Ni(2+) complexes with the chelating surfactant 4-C12-DTPA and different foaming agents were calculated by Rubingh's regular solution theory. Parameters for the calculations were extracted from surface tension measurements and NMR diffusometry. The effects of metal ion coordination on the interactions between 4-C12-DTPA and the foaming agents could be linked to a previously established difference in coordination chemistry between the examined metal ions. As can be expected from mixtures of amphoteric surfactants, the interactions were strongly pH-dependent. Strong correlation was found between interaction parameter β(σ) for mixed monolayer formation and the phase-transfer efficiency of Ni(2+) complexes with 4-C12-DTPA during flotation in a customized flotation cell. In a mixture of Cu(2+) and Zn(2+), the significant difference in conditional stability constants (log K) between the metal complexes was utilized to selectively recover the metal complex with the highest log K (Cu(2+)) by ion flotation. Flotation experiments in an excess concentration of metal ions confirmed the coordination of more than one metal ion to the headgroup of 4-C12-DTPA.
The roles of salusins in atherosclerosis and related cardiovascular diseases.
Watanabe, Takuya; Sato, Kengo; Itoh, Fumiko; Iso, Yoshitaka; Nagashima, Masaharu; Hirano, Tsutomu; Shichiri, Masayoshi
2011-01-01
Human salusin-α and -β are related peptides of 28 and 20 amino acids, respectively, produced from the same precursor, prosalusin. Salusin-β exerts more potent mitogenic effects on human vascular smooth muscle cells (VSMCs) and fibroblasts than salusin-α. Human macrophage foam cell formation is significantly stimulated by salusin-β, but suppressed by salusin-α. Chronic salusin-β infusion into apolipoprotein E-knockout mice enhances atherosclerotic lesions, paralleling increases in foam cell formation and upregulation of scavenger receptors and of acyl-CoA:cholesterol acyltransferase-1 (ACAT1) in macrophages. In contrast, chronic salusin-α infusion reduces atherosclerotic lesions accompanied by significant suppression of foam cell formation owing to ACAT1 downregulation. Salusin-β is expressed in proliferative neointimal lesions of porcine coronary arteries after stenting. Salusin-α and -β immunoreactivity has been detected in human coronary atherosclerotic plaques, with dominance of salusin-β in macrophage foam cells, VSMCs, and fibroblasts. Serum salusin-α levels are markedly decreased in patients with angiographically proven coronary artery disease compared with patients with mild hypertension and healthy volunteers. Furthermore, among patients with acute coronary syndrome, serum salusin-α levels are decreased in accordance with the severity of coronary atherosclerotic lesions. These findings suggest that salusin-β may contribute to the pathogenesis of atherosclerosis. Decreased levels of salusin-α in circulating blood and vascular tissue are closely linked with human atherosclerosis. Therefore, salusin-α could be a candidate biomarker for atherosclerosis and may be therapeutically useful for prevention of atherosclerotic cardiovascular diseases. Copyright © 2011 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Forming foam structures with carbon foam substrates
Landingham, Richard L.; Satcher, Jr., Joe H.; Coronado, Paul R.; Baumann, Theodore F.
2012-11-06
The invention provides foams of desired cell sizes formed from metal or ceramic materials that coat the surfaces of carbon foams which are subsequently removed. For example, metal is located over a sol-gel foam monolith. The metal is melted to produce a metal/sol-gel composition. The sol-gel foam monolith is removed, leaving a metal foam.
Al Awamleh, Abdel Ghani Ibrahim
2018-01-01
PURPOSE The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS The mean RTQs were 12.29 ± 0.830 and 12.19 ± 0.713 Ncm after 7 days (P=.928) and 16.47 ± 1.324 and 16.17 ± 1.165 Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were 40 µm and consisted of numerous small pores, whereas pore sizes in the modSLA were 5 µm. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically. PMID:29503717
Ding, Ming; Andreasen, Christina M; Dencker, Mads L; Jensen, Anders E; Theilgaard, Naseem; Overgaard, Søren
2015-04-01
Cylindrical critical size defects were created at the distal femoral condyles bilaterally of eight female adult sheep. Titanium implants with 2-mm concentric gaps were inserted and the gaps were filled with one of the four materials: allograft; a synthetic 15-amino acid cell-binding peptide coated hydroxyapatite (ABM/P-15); hydroxyapatite + βtricalciumphosphate+ Poly-Lactic-Acid (HA/βTCP-PDLLA); or ABM/P-15+HA/βTCP-PDLLA. After nine weeks, bone-implant blocks were harvested and sectioned for micro-CT scanning, push-out test, and histomorphometry. Significant bone formation and implant fixation could be observed in all four groups. Interestingly, the microarchitecture of the ABM/P-15 group was significantly different from the control group. Tissue volume fraction and thickness were significantly greater in the ABM/P-15 group than in the allograft group. Bone formation and bone ingrowth to porous titanium implant were not significantly different among the four groups. The ABM/P-15 group had similar shear mechanical properties on implant fixation as the allograft group. Adding HA/βTCP-PDLLA to ABM/P-15 did not significantly change these parameters. This study revealed that ABM/P-15 had significantly bone formation in concentric gap, and its enhancements on bone formation and implant fixation were at least as good as allograft. It is suggested that ABM/P-15 might be a good alternative biomaterial for bone implant fixation in this well-validated critical-size defect gap model in sheep. Nevertheless, future clinical researches should focus on prospective, randomized, controlled trials in order to fully elucidate whether ABM/P-15 could be a feasible candidate for bone substitute material in orthopedic practices. © 2014 Wiley Periodicals, Inc.
Hakki, Sema S; Tatar, Gulsah; Dundar, Niyazi; Demiralp, Burak
2017-04-01
The aims of this in vitro study are to compare the efficacy of different cleaning methods in removing debris of failed implants and to detect thermal changes of the implants treated by various scaling instruments. Twenty-seven failed implants and two unused implants as control were included to this study-group 1: plastic curette (P), group 2: titanium curette (T), group 3: carbon curette (C), group 4: titanium brush (TB), group 5: Er:YAG laser (laser 1 (L1) 100 mJ/pulse at 10 Hz), group 6: Er:YAG laser (laser 2 (L2) 150 mJ/pulse at 10 Hz), group 7: Er:YAG laser (laser 3 (L3) 200 mJ/pulse at 10 Hz), group 8: ultrasonic scaler appropriate for titanium (US), group 9: air abrasive method (AA) + citric acid, and group 10: implantoplasty (I). The changes on the treated/untreated titanium surfaces and remnant debris were observed by scanning electron microscopy (SEM). Temperature of the implants before and after treatment was detected using a thermocouple. The use of air abrasive and citric acid combination and Er:YAG laser groups was found as the best methods for the decontamination of titanium surfaces of failed implant. When the hand instruments were compared, titanium curette was found better than both the plastic and the carbon curettes which leave plastics and carbon remnants on the titanium surface. The temperature was higher after hand instrumentation when compared to other experimental groups (p < 0.05). Within the limitations of the present in vitro model, it can be concluded that the best method for decontamination of the implant surface is the use of air abrasives and Er:YAG laser.
Desai, Ankita R; Maulvi, Furqan A; Pandya, Mihir M; Ranch, Ketan M; Vyas, Bhavin A; Shah, Shailesh A; Shah, Dinesh O
2018-05-29
Glaucoma is a chronic disease, which is currently treated using frequent high dose applications of an eye drop solution; this method is tedious, and most of patients are non-compliant to it. Contact lenses are emerging as a convenient option to sustain the release of ophthalmic drugs. However, the incorporation of a drug/formulation changes the optical and physical properties of contact lenses. Contact lens users have also reported pink eye syndrome; this makes contact lenses unsuitable to be accepted as a medical device. The objective of the present study was to design novel timolol and hyaluronic acid (comfort agent)-loaded semi-circular ring-implanted contact lenses that could uphold the release at therapeutic rates without compromising the critical lens properties. The drug-loaded rings were individually implanted within the periphery of the contact lenses using modified cast-moulding technology. Atomic force microscopy showed an average roughness of 12.38 nm for the implanted lens that was significantly lower as compared to that of the Freshlook contact lenses (116.27 nm). A major amount of timolol was leached (from 46.47 to 58.79%) during the monomer extraction and moist sterilization (autoclave) steps; therefore, the lenses were sterilized by radiation and packaged under dry conditions (dehydrated). The in vitro release data showed sustained release of timolol and hyaluronic acid up to 96 h. The in vivo drug release study on rabbit eyes showed the presence of timolol in tear fluid up to 72 h. The in vivo pharmacodynamics studies showed a reduction in IOP till 144 h with a low drug loading (154 μg) as compared to the case of a single instillation eye drop solution (250 μg). This study has demonstrated the successful application of implantation technology to co-deliver timolol and hyaluronic acid from contact lenses for an extended period of time to treat glaucoma.
Mistry, S; Kundu, D; Datta, S; Basu, D
2011-03-01
Current trends in clinical dental implant therapy include modification of titanium surfaces for the purpose of improving osseointegration by different additive (bioactive coatings) and subtractive processes (acid etching, grit-blasting). The aim of this study was to evaluate and compare the behaviour of hydroxyapatite and the newly developed bioactive glass coated implants (62 implants) in osseous tissue following implantation in 31 patients. Bioactive glass and hydroxyapatite was suitably coated on titanium alloy. Hydroxyapatite coating was applied on the implant surface by air microplasma spray technique and bioactive glass coating was applied by vitreous enamelling technique. The outcome was assessed up to 12 months after prosthetic loading using different clinical and radiological parameters. Hydroxyapatite and bioactive glass coating materials were non-toxic and biocompatible. Overall results showed that bioactive glass coated implants were as equally successful as hydroxyapatite in achieving osseointegration and supporting final restorations. The newly developed bioactive glass is a good alternative coating material for dental implants. © 2011 Australian Dental Association.
Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping
2015-01-01
To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair.
Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping
2015-01-01
Objective To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Methods Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. Results HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. Conclusion n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair. PMID:26504382
Technological parameters influence on the non-autoclaved foam concrete characteristics
NASA Astrophysics Data System (ADS)
Bartenjeva, Ekaterina; Mashkin, Nikolay
2017-01-01
Foam concretes are used as effective heat-insulating materials. The porous structure of foam concrete provides good insulating and strength properties that make them possible to be used as heat-insulating structural materials. Optimal structure of non-autoclaved foam concrete depends on both technological factors and properties of technical foam. In this connection, the possibility to manufacture heat-insulation structural foam concrete on a high-speed cavity plant with the usage of protein and synthetic foamers was estimated. This experiment was carried out using mathematical planning method, and in this case mathematical models were developed that demonstrated the dependence of operating performance of foam concrete on foaming and rotation speed of laboratory plant. The following material properties were selected for the investigation: average density, compressive strength, bending strength and thermal conductivity. The influence of laboratory equipment technological parameters on technical foam strength and foam stability coefficient in the cement paste was investigated, physical and mechanical properties of non-autoclaved foam concrete were defined based on investigated foam. As a result of investigation, foam concrete samples were developed with performance parameters ensuring their use in production. The mathematical data gathered demonstrated the dependence of foam concrete performance on the technological regime.
Role of foam drainage in producing protein aggregates in foam fractionation.
Li, Rui; Zhang, Yuran; Chang, Yunkang; Wu, Zhaoliang; Wang, Yanji; Chen, Xiang'e; Wang, Tao
2017-10-01
It is essential to obtain a clear understanding of the foam-induced protein aggregation to reduce the loss of protein functionality in foam fractionation. The major effort of this work is to explore the roles of foam drainage in protein aggregation in the entire process of foam fractionation with bovine serum albumin (BSA) as a model protein. The results show that enhancing foam drainage increased the desorption of BSA molecules from the gas-liquid interface and the local concentration of desorbed molecules in foam. Therefore, it intensified the aggregation of BSA in foam fractionation. Simultaneously, it also accelerated the flow of BSA aggregates from rising foam into the residual solution along with the drained liquid. Because enhancing foam drainage increased the relative content of BSA molecules adsorbed at the gas-liquid interface, it also intensified the aggregation of BSA during both the defoaming process and the storage of the foamate. Furthermore, enhancing foam drainage more readily resulted in the formation of insoluble BSA aggregates. The results are highly important for a better understanding of foam-induced protein aggregation in foam fractionation. Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Wenyan; Han, Wuxiao; Gao, Huiling; Zhang, Linlin; Wang, Shuai; Xing, Lili; Zhang, Yan; Xue, Xinyu
2018-01-25
As the concentration of different biomarkers in human body fluids are an important parameter of chronic disease, wearable biosensors for in situ analysis of body fluids with high sensitivity, real-time detection, flexibility and biocompatibility have significant potential therapeutic applications. In this paper, a flexible self-powered implantable electronic-skin (e-skin) for in situ body fluids analysis (urea/uric-acid) as a real-time kidney-disease diagnoser has been proposed based on the piezo-enzymatic-reaction coupling process of ZnO nanowire arrays. It can convert the mechanical energy of body movements into a piezoelectric impulse, and the outputting piezoelectric signal contains the urea/uric-acid concentration information in body fluids. This piezoelectric-biosensing process does not need an external electricity supply or battery. The e-skin was implanted under the abdominal skin of a mouse and provided in situ analysis of the kidney-disease parameters. These results provide a new approach for developing a self-powered in situ body fluids-analysis technique for chronic-disease diagnosis.
Vaithilingam, Jayasheelan; Kilsby, Samuel; Goodridge, Ruth D; Christie, Steven D R; Edmondson, Steve; Hague, Richard J M
2015-01-01
Surface modification of an implant with a biomolecule is used to improve its biocompatibility and to reduce post-implant complications. In this study, a novel approach has been used to functionalise phosphonic acid monolayers with a drug. Ti6Al4V components fabricated using selective laser melting (SLM) were functionalised with Paracetamol (a pharmaceutically relevant biomolecule) using phosphonic acid based self-assembled monolayers (SAMs). The attachment, stability of the monolayers on the SLM fabricated surface and functionalisation of SAMs with Paracetamol were studied using X-ray photoelectron spectroscopy (XPS) and surface wettability measurements. The obtained results confirmed that SAMs were stable on the Ti6Al4V surface for over four weeks and then began to desorb from the surface. The reaction used to functionalise the phosphonic acid monolayers with Paracetamol was noted to be successful. Thus, the proposed method has the potential to immobilise drugs/proteins to SAM coated surfaces and improve their biocompatibility and reduce post-implant complications. Copyright © 2014. Published by Elsevier B.V.
Enhanced rhamnolipids production via efficient foam-control using stop valve as a foam breaker.
Long, Xuwei; Shen, Chong; He, Ni; Zhang, Guoliang; Meng, Qin
2017-01-01
In this study, a stop valve was used as a foam breaker for dealing with the massive overflowing foam in rhamnolipid fermentation. As found, a stop valve at its tiny opening could break over 90% of the extremely stable rhamnolipid foam into enriched liquid when foam flows through the sharp gap in valve. The efficient foam-control by the stop valve considerably improved the rhamnolipid fermentation and significantly enhanced the rhamnolipid productivity by 83% compared to the regular fermentation. This efficient foam breaking was mainly achieved by a high shear rate in combination with fast separation of air from the collapsed foam. Altogether, the stop valve possessed a great activity in breaking rhamnolipid foam, and the involving mechanism holds the potential for developing efficient foam breakers for industrial rhamnolipid fermentation. Copyright © 2016. Published by Elsevier Ltd.
ZrP nanoplates based fire-fighting foams stabilizer
NASA Astrophysics Data System (ADS)
Zhang, Lecheng; Cheng, Zhengdong; Li, Hai
2015-03-01
Firefighting foam, as a significant innovation in fire protection, greatly facilitates extinguishments for liquid pool fire. Recently, with developments in LNG industry, high-expansion firefighting foams are also used for extinguishing LNG fire or mitigating LNG leakage. Foam stabilizer, an ingredient in fire-fighting foam, stabilizes foam bubbles and maintains desired foam volume. Conventional foam stabilizers are organic molecules. In this work, we developed a inorganic based ZrP (Zr(HPO4)2 .H2O, Zirconium phosphate) plates functionalized as firefighting foam stabilizer, improving firefighting foam performance under harsh conditions. Several tests were conducted to illustrate performance. The mechanism for the foam stabilization is also proposed. Artie McFerrin Department of Chemical Engineering, Texas A&M University, College Station, TX 77843, USA. Mary Kay O'Connor Process Safety Center, Texas A&M University, College Station, TX, 77843-3122
Foam, Foam-resin composite and method of making a foam-resin composite
NASA Technical Reports Server (NTRS)
MacArthur, Doug E. (Inventor); Cranston, John A. (Inventor)
1995-01-01
This invention relates to a foam, a foam-resin composite and a method of making foam-resin composites. The foam set forth in this invention comprises a urethane modified polyisocyanurate derived from an aromatic amino polyol and a polyether polyol. In addition to the polyisocyanurate foam, the composite of this invention further contains a resin layer, wherein the resin may be epoxy, bismaleimide, or phenolic resin. Such resins generally require cure or post-cure temperatures of at least 350.degree. F.
Surface Modifications and Their Effects on Titanium Dental Implants
Jemat, A.; Ghazali, M. J.; Razali, M.; Otsuka, Y.
2015-01-01
This review covers several basic methodologies of surface treatment and their effects on titanium (Ti) implants. The importance of each treatment and its effects will be discussed in detail in order to compare their effectiveness in promoting osseointegration. Published literature for the last 18 years was selected with the use of keywords like titanium dental implant, surface roughness, coating, and osseointegration. Significant surface roughness played an important role in providing effective surface for bone implant contact, cell proliferation, and removal torque, despite having good mechanical properties. Overall, published studies indicated that an acid etched surface-modified and a coating application on commercial pure titanium implant was most preferable in producing the good surface roughness. Thus, a combination of a good surface roughness and mechanical properties of titanium could lead to successful dental implants. PMID:26436097
Espresso coffee foam delays cooling of the liquid phase.
Arii, Yasuhiro; Nishizawa, Kaho
2017-04-01
Espresso coffee foam, called crema, is known to be a marker of the quality of espresso coffee extraction. However, the role of foam in coffee temperature has not been quantitatively clarified. In this study, we used an automatic machine for espresso coffee extraction. We evaluated whether the foam prepared using the machine was suitable for foam analysis. After extraction, the percentage and consistency of the foam were measured using various techniques, and changes in the foam volume were tracked over time. Our extraction method, therefore, allowed consistent preparation of high-quality foam. We also quantitatively determined that the foam phase slowed cooling of the liquid phase after extraction. High-quality foam plays an important role in delaying the cooling of espresso coffee.
Systematic Review: Rectal Therapies for the Treatment of Distal Forms of Ulcerative Colitis.
Cohen, Russell D; Dalal, Sushila R
2015-07-01
Many therapeutic options are available for patients with distal forms of ulcerative colitis (UC). Rectal therapies (e.g., suppositories, foams, gels, and enemas) may be recommended either alone or in combination with oral treatment. Compared with oral therapies, rectal therapies are underused in patients with distal forms of UC, although rectal therapies have favorable efficacy and safety profiles. This systematic review identified 48 articles for inclusion after a comprehensive PubMed search and the identification of additional relevant articles through other sources. Inclusion criteria were clinical studies examining efficacy and safety of 5-aminosalicylic acid, corticosteroid, and non-5-aminosalicylic acid rectal therapies (suppositories, foams, gels, and enemas) that induce or maintain remission in patients with ulcerative proctitis, ulcerative proctosigmoiditis, or left-sided colitis (i.e., distal forms of UC). The quality of the evidence presented was evaluated using the GRADE system. Overall, a greater percentage of patients with distal forms of UC receiving 5-aminosalicylic acids or corticosteroid rectal formulations derived greater therapeutic benefit after treatment compared with patients receiving placebo. Furthermore, most uncontrolled studies of rectal therapies reported that patients with distal forms of UC had marked improvement from baseline after treatment. The overall safety profile of rectal therapies was favorable. Treatment with second-generation corticosteroids, such as budesonide and beclomethasone dipropionate, did not increase the incidence of steroid-related adverse effects. The current literature supports the use of rectal therapies for both induction and maintenance of remission in patients with distal forms of UC.
Imunohistological aspects of the tissue around dental implants
NASA Astrophysics Data System (ADS)
Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru
2016-03-01
Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.
Generation of sclerosant foams by mechanical methods increases the foam temperature.
Tan, Lulu; Wong, Kaichung; Connor, David; Fakhim, Babak; Behnia, Masud; Parsi, Kurosh
2017-08-01
Objective To investigate the effect of agitation on foam temperature. Methods Sodium tetradecyl sulphate and polidocanol were used. Prior to foam generation, the sclerosant and all constituent equipment were cooled to 4-25℃ and compared with cooling the sclerosant only. Foam was generated using a modified Tessari method. During foam agitation, the temperature change was measured using a thermocouple for 120 s. Results Pre-cooling all the constituent equipment resulted in a cooler foam in comparison with only cooling the sclerosant. A starting temperature of 4℃ produced average foam temperatures of 12.5 and 13.2℃ for sodium tetradecyl sulphate and polidocanol, respectively. It was also found that only cooling the liquid sclerosant provided minimal cooling to the final foam temperature, with the temperature 20 and 20.5℃ for sodium tetradecyl sulphate and polidocanol, respectively. Conclusion The foam generation process has a noticeable impact on final foam temperature and needs to be taken into consideration when creating foam.
Cao, Hongdan; Yang, Xiaodong; Wu, Dayi; Zhang, Xingdong
2007-04-01
The roughness treatment of dental implant surface could improve the bone bonding and increase the success rate of implant, but the difference of diverse treatments is still unknown. In this study using scanning electron microscopy (SEM), energy disperse spectrometer (EDS) and the test of contact angle, we studied the microstructure, surface contamination and surface energy, and hence conducted a comparative analysis of the following surface roughness treatments: Polished Treatment (PT), Sandblasting with Alumina(SA), Sandblasting with Aluminia and Acid-etched (SAA), Sandblasting with Titanium Acid-etched (STA), Electro-erosion Treatment(ET). The result of SEM showed that the surface displayed irregularities after roughness treatments and that the surface properties of different roughness treatments had some distinctions. SAA and SA had some sharp edges and protrutions; the STA showed a regular pattern like honeycomb, but the ET sample treated by electric erosion exhibited the deeper pores of different sizes and the pores with a perforated secondary structure. The EDS indicated that the surface was contaminated after the treatment with foreign materials; the SA surface had some embedded contaminations even after acid etching. The measurement of water contact angle indicated that the morphology correlated with the surface treatments. These findings suggest that the distinction of surface structure and composition caused by different treatments may result in the disparity in biological behavior of dental implant.
Infiltrated carbon foam composites
NASA Technical Reports Server (NTRS)
Lucas, Rick D. (Inventor); Danford, Harry E. (Inventor); Plucinski, Janusz W. (Inventor); Merriman, Douglas J. (Inventor); Blacker, Jesse M. (Inventor)
2012-01-01
An infiltrated carbon foam composite and method for making the composite is described. The infiltrated carbon foam composite may include a carbonized carbon aerogel in cells of a carbon foam body and a resin is infiltrated into the carbon foam body filling the cells of the carbon foam body and spaces around the carbonized carbon aerogel. The infiltrated carbon foam composites may be useful for mid-density ablative thermal protection systems.
Foam property tests to evaluate the potential for longwall shield dust control.
Reed, W R; Beck, T W; Zheng, Y; Klima, S; Driscoll, J
2018-01-01
Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration's lower coal mine respirable dust standard of 1.5 mg/m 3 . Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control.
Foam property tests to evaluate the potential for longwall shield dust control
Reed, W.R.; Beck, T.W.; Zheng, Y.; Klima, S.; Driscoll, J.
2018-01-01
Tests were conducted to determine properties of four foam agents for their potential use in longwall mining dust control. Foam has been tried in underground mining in the past for dust control and is currently being reconsidered for use in underground coal longwall operations in order to help those operations comply with the Mine Safety and Health Administration’s lower coal mine respirable dust standard of 1.5 mg/m3. Foams were generated using two different methods. One method used compressed air and water pressure to generate foam, while the other method used low-pressure air generated by a blower and water pressure using a foam generator developed by the U.S. National Institute for Occupational Safety and Health. Foam property tests, consisting of a foam expansion ratio test and a water drainage test, were conducted to classify foams. Compressed-air-generated foams tended to have low expansion ratios, from 10 to 19, with high water drainage. Blower-air-generated foams had higher foam expansion ratios, from 30 to 60, with lower water drainage. Foams produced within these ranges of expansion ratios are stable and potentially suitable for dust control. The test results eliminated two foam agents for future testing because they had poor expansion ratios. The remaining two foam agents seem to have properties adequate for dust control. These material property tests can be used to classify foams for their potential use in longwall mining dust control. PMID:29416179
Multiscale Analysis of Open-Cell Aluminum Foam for Impact Energy Absorption
NASA Astrophysics Data System (ADS)
Kim, Ji Hoon; Kim, Daeyong; Lee, Myoung-Gyu; Lee, Jong Kook
2016-09-01
The energy-absorbing characteristics of crash members in automotive collision play an important role in controlling the amount of damage to the passenger compartment. Aluminum foams have high strength-to-weight ratio and high deformability, thus good crashworthiness is expected while maintaining or even saving weights when foams are implemented in crash members. In order to investigate the effect of the open-cell aluminum foam fillers on impact performance and weight saving, a multiscale framework for evaluating the crashworthiness of aluminum foam-filled members is used. To circumvent the difficulties of mechanical tests on foams, a micromechanical model of the aluminum foam is constructed using the x-ray micro tomography and virtual tests are conducted for the micromechanical model to characterize the behavior of the foam. In the macroscale, the aluminum foam is represented by the crushable foam constitutive model, which is then incorporated into the impact test simulation of the foam-filled crash member. The multiscale foam-filled crash member model was validated for the high-speed impact test, which confirms that the material model characterized by the micromechanical approach represents the behavior of the open-cell foam under impact loading well. Finally, the crash member design for maximizing the energy absorption is discussed by investigating various designs from the foam-only structure to the hollow tube structure. It was found that the foam structure absorbs more energy than the hollow tube or foam-filled structure with the same weight.
Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.
Sabir, Mohammad; Alam, Mohammad Nazish
2015-06-01
The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.
An Implantable MEMS Drug Delivery Device for Rapid Delivery in Ambulatory Emergency Care
2009-06-01
controlled devices provide advantages over passive release devices, as the drug delivery process can be controlled actively after implantation and...mm, 5 μm, 100 Å, Alltech Associates, USA), with methanol and 0.1% trifluoroacetic acid (TFA) in water. The gradient used was 2 % TFA/min, starting
Qualitative and quantitative observations of bone tissue reactions to anodised implants.
Sul, Young-Taeg; Johansson, Carina B; Röser, Kerstin; Albrektsson, Tomas
2002-04-01
Research projects focusing on biomaterials related factors; the bulk implant material, the macro-design of the implant and the microsurface roughness are routinely being conducted at our laboratories. In this study, we have investigated the bone tissue reactions to turned commercially pure (c.p.) titanium implants with various thicknesses of the oxide films after 6 weeks of insertion in rabbit bone. The control c.p. titanium implants had an oxide thickness of 17-200 nm while the test implants revealed an oxide thickness between 600 and 1000 nm. Routine histological investigations of the tissue reactions around the implants and enzyme histochemical detections of alkaline and acid phosphatase activities demonstrated similar findings around both the control and test implants. In general, the histomorphometrical parameters (bone to implant contact and newly formed bone) revealed significant quantitative differences between the control and test implants. The test implants demonstrated a greater bone response histomorphometrically than control implants and the osteoconductivity was more pronounced around the test implant surfaces. The parameters that differed between the implant surfaces, i.e. the oxide thickness, the pore size distribution, the porosity and the crystallinity of the surface oxides may represent factors that have an influence on the histomorphometrical results indicated by a stronger bone tissue response to the test implant surfaces, with an oxide thickness of more than 600 nm.
NASA Astrophysics Data System (ADS)
Rădulescu, Dragoş; Grumezescu, Valentina; Andronescu, Ecaterina; Holban, Alina Maria; Grumezescu, Alexandru Mihai; Socol, Gabriel; Oprea, Alexandra Elena; Rădulescu, Marius; Surdu, Adrian; Trusca, Roxana; Rădulescu, Radu; Chifiriuc, Mariana Carmen; Stan, Miruna S.; Constanda, Sabrina; Dinischiotu, Anca
2016-06-01
In this study we aimed to obtain functionalized thin films based on hydroxyapatite/poly(lactic-co-glycolic acid) (HAp/PLGA) containing ceftriaxone/cefuroxime antibiotics (ATBs) deposited by Matrix Assisted Pulsed Laser Evaporation (MAPLE) technique. The prepared thin films were characterized by transmission electron microscopy (TEM), scanning electron microscopy (SEM), X-Ray diffraction (XRD), selected area electron diffraction (SAED), and infra red (IR) analysis. HAp/PLGA/ATBs thin films sustained the growth of human osteoblasts, proving their good biocompatibility. The microscopic evaluation and the culture-based quantitative assay of the E. coli biofilm development showed that the thin films inhibited the initial step of microbial attachment as well as the subsequent colonization and biofilm development on the respective surfaces. This study demonstrates that MAPLE technique could represent an appealing technique for the fabrication of antibiotics-containing polymeric implant coatings. The bioevaluation results recommend this type of surfaces for the prevention of bone implant microbial contamination and for the enhanced stimulation of the implant osseointegration process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanekoff, Ingela; Cha, Jeeyeon; Kyle, Jennifer E.
Here we demonstrate that conditional deletion of mouse uterine Trp53 (p53d/d), molecularly linked to mTORC1 activation and causally linked to premature uterine senescence and preterm birth, results in aberrant lipid signatures within the heterogeneous cell types of embryo implantation sites on day 8 of pregnancy. In situ nanospray desorption electrospray ionization mass spectrometry imaging (nano-DESI MSI) was used to characterize the molecular speciation of free fatty acids, monoacylglycerols, unmodified and oxidized phosphatidylcholine (PC/Ox-PC), and diacylglycerol (DG) species within implantation sites of p53d/d mice and floxed littermates. Implantation sites from p53d/d mice exhibited distinct spatially resolved changes demonstrating accumulation of DGmore » species, depletion of Ox-PC species, and increase in species with more unsaturated acyl chains, including arachidonic and docosahexaenoic acid. Understanding abnormal changes in the abundance and localization of individual lipid species early in the progression to premature birth is important for discovering novel targets for treatments and diagnosis.« less
NASA Astrophysics Data System (ADS)
Lanekoff, Ingela; Cha, Jeeyeon; Kyle, Jennifer E.; Dey, Sudhansu K.; Laskin, Julia; Burnum-Johnson, Kristin E.
2016-09-01
Here we demonstrate that conditional deletion of mouse uterine Trp53 (p53d/d), molecularly linked to mTORC1 activation and causally linked to premature uterine senescence and preterm birth, results in aberrant lipid signatures within the heterogeneous cell types of embryo implantation sites on day 8 of pregnancy. In situ nanospray desorption electrospray ionization mass spectrometry imaging (nano-DESI MSI) was used to characterize the molecular speciation of free fatty acids, monoacylglycerol species, unmodified and oxidized phosphatidylcholine (PC/Ox-PC), and diacylglycerol (DG) species within implantation sites of p53d/d mice and floxed littermates. Implantation sites from p53d/d mice exhibited distinct spatially resolved changes demonstrating accumulation of DG species, depletion of Ox-PC species, and increase in species with more unsaturated acyl chains, including arachidonic and docosahexaenoic acid. Understanding abnormal changes in the abundance and localization of individual lipid species early in the progression to premature birth is an important step toward discovering novel targets for treatments and diagnosis.
Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation
NASA Technical Reports Server (NTRS)
Hess, David M.
2013-01-01
The primary application for cryogenic insulating foams will be fuel tank applications for fueling systems. It is crucial for this insulation to be incorporated into systems that survive vacuum and terrestrial environments. It is hypothesized that by forming an open-cell silica-reinforced polymer structure, the foam structures will exhibit the necessary strength to maintain shape. This will, in turn, maintain the insulating capabilities of the foam insulation. Besides mechanical stability in the form of crush resistance, it is important for these insulating materials to exhibit water penetration resistance. Hydrocarbon-terminated foam surfaces were implemented to impart hydrophobic functionality that apparently limits moisture penetration through the foam. During the freezing process, water accumulates on the surfaces of the foams. However, when hydrocarbon-terminated surfaces are present, water apparently beads and forms crystals, leading to less apparent accumulation. The object of this work is to develop inexpensive structural cryogenic insulation foam that has increased impact resistance for launch and ground-based cryogenic systems. Two parallel approaches will be pursued: a silica-polymer co-foaming technique and a post foam coating technique. Insulation characteristics, flexibility, and water uptake can be fine-tuned through the manipulation of the polyurethane foam scaffold. Silicate coatings for polyurethane foams and aerogel-impregnated polyurethane foams have been developed and tested. A highly porous aerogel-like material may be fabricated using a co-foam and coated foam techniques, and can insulate at liquid temperatures using the composite foam
Fan, Donglei; Li, Minggang; Qiu, Jian; Xing, Haiping; Jiang, Zhiwei; Tang, Tao
2018-05-31
Auxetic materials are a class of materials possessing negative Poisson's ratio. Here we establish a novel method for preparing auxetic foam from closed-cell polymer foam based on steam penetration and condensation (SPC) process. Using polyethylene (PE) closed-cell foam as an example, the resultant foams treated by SPC process present negative Poisson's ratio during stretching and compression testing. The effect of steam-treated temperature and time on the conversion efficiency of negative Poisson's ratio foam is investigated, and the mechanism of SPC method for forming re-entrant structure is discussed. The results indicate that the presence of enough steam within the cells is a critical factor for the negative Poisson's ratio conversion in the SPC process. The pressure difference caused by steam condensation is the driving force for the conversion from conventional closed-cell foam to the negative Poisson's ratio foam. Furthermore, the applicability of SPC process for fabricating auxetic foam is studied by replacing PE foam by polyvinyl chloride (PVC) foam with closed-cell structure or replacing water steam by ethanol steam. The results verify the universality of SPC process for fabricating auxetic foams from conventional foams with closed-cell structure. In addition, we explored potential application of the obtained auxetic foams by SPC process in the fabrication of shape memory polymer materials.
mdFoam+: Advanced molecular dynamics in OpenFOAM
NASA Astrophysics Data System (ADS)
Longshaw, S. M.; Borg, M. K.; Ramisetti, S. B.; Zhang, J.; Lockerby, D. A.; Emerson, D. R.; Reese, J. M.
2018-03-01
This paper introduces mdFoam+, which is an MPI parallelised molecular dynamics (MD) solver implemented entirely within the OpenFOAM software framework. It is open-source and released under the same GNU General Public License (GPL) as OpenFOAM. The source code is released as a publicly open software repository that includes detailed documentation and tutorial cases. Since mdFoam+ is designed entirely within the OpenFOAM C++ object-oriented framework, it inherits a number of key features. The code is designed for extensibility and flexibility, so it is aimed first and foremost as an MD research tool, in which new models and test cases can be developed and tested rapidly. Implementing mdFoam+ in OpenFOAM also enables easier development of hybrid methods that couple MD with continuum-based solvers. Setting up MD cases follows the standard OpenFOAM format, as mdFoam+ also relies upon the OpenFOAM dictionary-based directory structure. This ensures that useful pre- and post-processing capabilities provided by OpenFOAM remain available even though the fully Lagrangian nature of an MD simulation is not typical of most OpenFOAM applications. Results show that mdFoam+ compares well to another well-known MD code (e.g. LAMMPS) in terms of benchmark problems, although it also has additional functionality that does not exist in other open-source MD codes.
Gurjar, Jigar; Sengupta, Bina
2015-08-01
Rice mill polishing residue (RMPR), an abundant and cheap agro residue, was used as substrate for microbial growth of Bacillus subtilis MTCC 2423 by submerged fermentation process to produce surfactin. Nutrients present in the residue were sufficient to sustain the growth of the microorganism. Multi stage foam fractionation followed by acid precipitation was used to concentrate and recover the product. Recoverable yield of surfactin was 4.17 g/kg residue. Product recovered in the foamate accounted for 69% of the total yield. The residual broth containing ∼ 30% surfactin exhibited biological oxygen demand and chemical oxygen demand values of 23 and 69 mg/L respectively. The microbial growth data was correlated using three parameter sigmoid models. Surfactin synthesized had a predominance of molecular weight 1076 Da. Foam separation of copper using surfactin resulted in a maximum removal of 72.5%. Copyright © 2015 Elsevier Ltd. All rights reserved.
Matsumoto, Fumi; Matsui, Futoshi; Yazawa, Koji; Shimada, Kenji
2017-01-01
Since 2011, endoscopic correction of vesicoureteral reflux using dextranomer-hyaluronic acid copolymer (Deflux ® ) has been widely accepted in Japan due to its safety and minimally invasive nature. However, long-term complications are unknown. We present a case of Deflux ® implants calcification mimicking distal ureteral calculi in a 12-year-old boy with a history of Deflux ® injection performed at three years of age for primary VUR. We should be aware of this complication to avoid misdiagnosis and unnecessary invasive examination such as radiological imaging or endoscopy.
46 CFR 108.473 - Foam system components.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Foam system components. 108.473 Section 108.473 Shipping... EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.473 Foam system components. (a) Each foam agent, each tank for a foam agent, each discharge outlet, each control, and each valve for the...
46 CFR 108.473 - Foam system components.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Foam system components. 108.473 Section 108.473 Shipping... EQUIPMENT Fire Extinguishing Systems Foam Extinguishing Systems § 108.473 Foam system components. (a) Each foam agent, each tank for a foam agent, each discharge outlet, each control, and each valve for the...
Initial Evaluation of Burn Characteristics of Phenolic Foam Runway Brake Arrestor Material
1993-12-01
foam immersed in a jet fuel fire when extinguished using 3-percent Aqueous Film Forming Foam ( AFFF ). Three pool...extinguishment time of phenolic foam immersed in a jet fuel fire, using 3-percent Aqueous Film Forming Foam ( AFFF ) extinguishing agent. The wind was negligible...percent Aqueous Film Forming Foam ( AFFF ) agent. This project is an initial assessment of the fire safety of phenolic foam
Electrostatic Safety with Explosion Suppressant Foams.
1983-03-01
the foam, and (2) sorption of alkylphenol type substances, present as oxidation inhibitors in the fuel, by the foam. It had been previously reported... alkylphenol type substances. The use of antistatic ingredients in the reticulated polyurethane foam was suggested as a means of minimizing static...foam with JP-4 are: o Removal of diethylhexyl phthalate from the foam. o Sorption of alkylphenol type compounds by the foam. Tne latter of these two
Impact of foamed matrix components on foamed concrete properties
NASA Astrophysics Data System (ADS)
Tarasenko, V. N.
2018-03-01
The improvement of the matrix foam structure by means of foam stabilizing additives is aimed at solving the technology-oriented problems as well as at the further improvement of physical and mechanical properties of cellular-concrete composites. The dry foam mineralization is the mainstream of this research. Adding the concrete densifiers, foam stabilizers and mineral powders reduces the drying shrinkage, which makes the foam concrete products technologically effective.
Foam-mat drying technology: A review.
Hardy, Z; Jideani, V A
2017-08-13
This article reviews various aspects of foam-mat drying such as foam-mat drying processing technique, main additives used for foam-mat drying, foam-mat drying of liquid and solid foods, quality characteristics of foam-mat dried foods, and economic and technical benefits for employing foam-mat drying. Foam-mat drying process is an alternative method that allows the removal of water from liquid materials and pureed materials. In this drying process, a liquid material is converted into foam that is stable by being whipped after adding an edible foaming agent. The stable foam is then spread out in sheet or mat and dried by using hot air (40-90°C) at atmospheric pressure. Methyl cellulose (0.25-2%), egg white (3-20%), maltodextrin (0.5-05%), and gum Arabic (2-9%) are the commonly utilized additives for the foam-mat drying process at the given range, either combined together for their effectiveness or individual effect. The foam-mat drying process is suitable for heat sensitive, viscous, and sticky products that cannot be dried using other forms of drying methods such as spray drying because of the state of product. More interest has developed for foam-mat drying because of the simplicity, cost effectiveness, high speed drying, and improved product quality it provides.
Application of an Elongated Kelvin Model to Space Shuttle Foams
NASA Technical Reports Server (NTRS)
Sullivan, Roy M.; Ghosn, Louis J.; Lerch, Bradley A.
2009-01-01
The space shuttle foams are rigid closed-cell polyurethane foams. The two foams used most-extensively oil space shuttle external tank are BX-265 and NCFL4-124. Because of the foaming and rising process, the foam microstructures are elongated in the rise direction. As a result, these two foams exhibit a nonisotropic mechanical behavior. A detailed microstructural characterization of the two foams is presented. Key features of the foam cells are described and the average cell dimensions in the two foams are summarized. Experimental studies are also conducted to measure the room temperature mechanical response of the two foams in the two principal material directions (parallel to the rise and perpendicular to the rise). The measured elastic modulus, proportional limit stress, ultimate tensile strength, and Poisson's ratios are reported. The generalized elongated Kelvin foam model previously developed by the authors is reviewed and the equations which result from this model are summarized. Using the measured microstructural dimensions and the measured stiffness ratio, the foam tensile strength ratio and Poisson's ratios are predicted for both foams and are compared with the experimental data. The predicted tensile strength ratio is in close agreement with the measured strength ratio for both BX-265 and NCFI24-124. The comparison between the predicted Poisson's ratios and the measured values is not as favorable.
Foam Transport in Porous Media - A Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Z. F.; Freedman, Vicky L.; Zhong, Lirong
2009-11-11
Amendment solutions with or without surfactants have been used to remove contaminants from soil. However, it has drawbacks such that the amendment solution often mobilizes the plume, and its movement is controlled by gravity and preferential flow paths. Foam is an emulsion-like, two-phase system in which gas cells are dispersed in a liquid and separated by thin liquid films called lamellae. Potential advantages of using foams in sub-surface remediation include providing better control on the volume of fluids injected, uniformity of contact, and the ability to contain the migration of contaminant laden liquids. It is expected that foam can servemore » as a carrier of amendments for vadose zone remediation, e.g., at the Hanford Site. As part of the U.S. Department of Energy’s EM-20 program, a numerical simulation capability will be added to the Subsurface Transport Over Multiple Phases (STOMP) flow simulator. The primary purpose of this document is to review the modeling approaches of foam transport in porous media. However, as an aid to understanding the simulation approaches, some experiments under unsaturated conditions and the processes of foam transport are also reviewed. Foam may be formed when the surfactant concentration is above the critical micelle concentration. There are two main types of foams – the ball foam (microfoam) and the polyhedral foam. The characteristics of bulk foam are described by the properties such as foam quality, texture, stability, density, surface tension, disjoining pressure, etc. Foam has been used to flush contaminants such as metals, organics, and nonaqueous phase liquids from unsaturated soil. Ball foam, or colloidal gas aphrons, reportedly have been used for soil flushing in contaminated site remediation and was found to be more efficient than surfactant solutions on the basis of weight of contaminant removed per gram of surfactant. Experiments also indicate that the polyhedral foam can be used to enhance soil remediation. The transport of foam in porous media is complicated in that the number of lamellae present governs flow characteristics such as viscosity, relative permeability, fluid distribution, and interactions between fluids. Hence, foam is a non-Newtonian fluid. During transport, foam destruction and formation occur. The net result of the two processes determines the foam texture (i.e., bubble density). Some of the foam may be trapped during transport. According to the impacts of the aqueous and gas flow rates, foam flow generally has two regimes – weak and strong foam. There is also a minimum pressure gradient to initiate foam flow and a critical capillary for foam to be sustained. Similar to other fluids, the transport of foam is described by Darcy’s law with the exception that the foam viscosity is variable. Three major approaches to modeling foam transport in porous media are the empirical, semi-empirical, and mechanistic methods. Mechanistic approaches can be complete in principal but may be difficult to obtain reliable parameters, whereas empirical and semi-empirical approaches can be limited by the detail used to describe foam rheology and mobility. Mechanistic approaches include the bubble population-balance model, the network/percolation theory, the catastrophe theory, and the filtration theory. Among these methods, all were developed for modeling polyhedral foam with the exception that the method based on the filtration theory was for the ball foam (microfoam).« less
Xue, Bai-Liang; Wen, Jia-Long; Sun, Run-Cang
2015-01-01
Lignin-based polyols were synthesized through microwave-assisted liquefaction under different microwave heating times (5–30 min). The liquefaction reactions were carried out using polyethylene glycol (PEG-400)/glycerol as liquefying solvents and 97 wt% sulfur acid as a catalyst at 140 °C. The polyols obtained were analyzed for their yield, composition and structural characteristics using gel permeation chromatography (GPC), Fourier transform infrared (FT-IR) and nuclear magnetic resonance (NMR) spectra. FT-IR and NMR spectra showed that the liquefying solvents reacted with the phenol hydroxyl groups of the lignin in the liquefied product. With increasing microwave heating time, the viscosity of polyols was slightly increased and their corresponding molecular weight (MW) was gradually reduced. The optimal condition at the microwave heating time (5 min) ensured a high liquefaction yield (97.47%) and polyol with a suitable hydroxyl number (8.628 mmol/g). Polyurethane (PU) foams were prepared by polyols and methylene diphenylene diisocyanate (MDI) using the one-shot method. With the isocyanate/hydroxyl group ([NCO]/[OH]) ratio increasing from 0.6 to 1.0, their mechanical properties were gradually increased. This study provided some insight into the microwave-assisted liquefied lignin polyols for the production of rigid PU foam. PMID:28787959
Study on the generation of perfluorooctane sulfonate from the aqueous film-forming foam.
Kishi, Takahiro; Arai, Mitsuru
2008-11-15
Perfluorooctane sulfonate (C(8)HF(17)SO(3)) and perfluorooctane acid (C(8)HF(15)O(2)) are artificial chemicals and have been used all over the world, mainly as water repellent agents, fluorochemical surfactants, coating agents, etc. However, perfluorooctane sulfonate and perfluorooctane acid are environmental contaminants because of their stability, bio-accumulativeness, and long-term persistence in the ecological environment. At the present day, they are diffused all over the world. Lately, this diffusion is viewed with suspicion and there is a movement towards their restriction, even if the environmental fate of them is still under investigation. Fluorochemical surfactants are key compounds in the aqueous film-forming foam (AFFF) formulations. AFFFs are used for massive conflagration such as industrial fire and petroleum fire because of their efficient fire control. On the other hand, a lot of AFFFs are used in case of massive conflagration and most of them enter ocean and groundwater. Actually, perfluorooctane sulfonate and perfluorooctane sulfonate related substances were detected from the fire-fighting facility of US forces. Therefore, there is the possibility of generating perfluorooctane sulfonate and perfluorooctane sulfonate related substances from fluorochemical surfactants in the AFFFs. In this study, activated sludge added AFFF were analyzed for perfluorooctane sulfonate and perfluorooctane acid with time. And the perfluorooctane sulfonate was directly detected after 2 days using LC-MS. This shows that AFFF can be decomposed perfluorooctane sulfonate by microorganisms easily. However, perfluorooctane sulfonate would not decompose at all. Additionally, activated sludge added N-polyoxyethylene-N-propyl perfluorooctane sulfonamide which is one of the fluorochemical surfactants used in the AFFF was analyzed for perfluorooctane sulfonate and perfluorooctane acid with time and the perfluorooctane sulfonate was detected too.
Filipovic, Marko; Woldegiorgis, Andreas; Norström, Karin; Bibi, Momina; Lindberg, Maria; Österås, Ann-Helen
2015-06-01
Historical usage of aqueous film forming foams (AFFFs) at military airports is a potential source of perfluoroalkyl acids (PFAAs) to the nearby environment. In this study, the distribution of perfluorohexanoic acid (PFHxA), perfluorooctanoic acid (PFOA), perfluorohexane sulfonate (PFHxS) and perfluorooctane sulfonate (PFOS) in soil, groundwater, surface water, tap water well, and fish muscle was investigated at a closed down military airfield (F18) and its surroundings in Stockholm, Sweden. The presence of PFOS at AFFF training sites was inventoried. One major finding of the study is that a former airfield, abandoned since 1994, may still be a point source of PFAAs to nearby recipients. PFOS and PFOA were ubiquitous in the soil samples at former AFFF training sites with concentrations ranging from 2.18 to 8520ngg(-1) dry weight and <0.12-287ngg(-1) dry weight respectively. The sum of PFAAs in the groundwater and surface waters ranged from 738 to 51000ngL(-1) and
Advanced nondestructive techniques applied for the detection of discontinuities in aluminum foams
NASA Astrophysics Data System (ADS)
Katchadjian, Pablo; García, Alejandro; Brizuela, Jose; Camacho, Jorge; Chiné, Bruno; Mussi, Valerio; Britto, Ivan
2018-04-01
Metal foams are finding an increasing range of applications by their lightweight structure and physical, chemical and mechanical properties. Foams can be used to fill closed moulds for manufacturing structural foam parts of complex shape [1]; foam filled structures are expected to provide good mechanical properties and energy absorption capabilities. The complexity of the foaming process and the number of parameters to simultaneously control, demand a preliminary and hugely wide experimental activity to manufacture foamed components with a good quality. That is why there are many efforts to improve the structure of foams, in order to obtain a product with good properties. The problem is that even for seemingly identical foaming conditions, the effective foaming can vary significantly from one foaming trial to another. The variation of the foams often is related by structural imperfections, joining region (foam-foam or foam-wall mold) or difficulties in achieving a complete filling of the mould. That is, in a closed mold, the result of the mold filling and its structure or defects are not known a priori and can eventually vary significantly. These defects can cause a drastic deterioration of the mechanical properties [2] and lead to a low performance in its application. This work proposes the use of advanced nondestructive techniques for evaluating the foam distribution after filling the mold to improve the manufacturing process. To achieved this purpose ultrasonic technique (UT) and cone beam computed tomography (CT) were applied on plate and structures of different thicknesses filled with foam of different porosity. UT was carried out on transmission mode with low frequency air-coupled transducers [3], in focused and unfocused configurations.
Analysis of Influence of Foaming Mixture Components on Structure and Properties of Foam Glass
NASA Astrophysics Data System (ADS)
Karandashova, N. S.; Goltsman, B. M.; Yatsenko, E. A.
2017-11-01
It is recommended to use high-quality thermal insulation materials to increase the energy efficiency of buildings. One of the best thermal insulation materials is foam glass - durable, porous material that is resistant to almost any effect of substance. Glass foaming is a complex process depending on the foaming mode and the initial mixture composition. This paper discusses the influence of all components of the mixture - glass powder, foaming agent, enveloping material and water - on the foam glass structure. It was determined that glass powder is the basis of the future material. A foaming agent forms a gas phase in the process of thermal decomposition. This aforementioned gas foams the viscous glass mass. The unreacted residue thus changes a colour of the material. The enveloping agent slows the foaming agent decomposition preventing its premature burning out and, in addition, helps to accelerate the sintering of glass particles. The introduction of water reduces the viscosity of the foaming mixture making it evenly distributed and also promotes the formation of water gas that additionally foams the glass mass. The optimal composition for producing the foam glass with the density of 150 kg/m3 is defined according to the results of the research.
Foams for barriers and nonlethal weapons
NASA Astrophysics Data System (ADS)
Rand, Peter B.
1997-01-01
Our times demand better solutions to conflict resolution than simply shooting someone. Because of this, police and military interest in non-lethal concepts is high. Already in use are pepper sprays, bean-bag guns, flash-bang grenades, and rubber bullets. At Sandia we got a head start on non- lethal weapon concepts. Protection of nuclear materials required systems that went way beyond the traditional back vault. Dispensable deterrents were used to allow a graduated response to a threat. Sticky foams and stabilized aqueous foams were developed to provide access delay. Foams won out for security systems simply because you could get a large volume from a small container. For polymeric foams the expansion ratio is thirty to fifty to one. In aqueous foams expansion ratios of one thousand to ne are easily obtained. Recent development work on sticky foams has included a changeover to environmentally friendly solvents, foams with very low toxicity, and the development of non-flammable silicone resin based foams. High expansion aqueous foams are useful visual and aural obscurants. Our recent aqueous foam development has concentrated on using very low toxicity foaming agents combined with oleoresin capsicum irritant to provide a safe but highly irritating foam.
Benefits of polidocanol endovenous microfoam (Varithena®) compared with physician-compounded foams
Carugo, Dario; Ankrett, Dyan N; Zhao, Xuefeng; Zhang, Xunli; Hill, Martyn; O’Byrne, Vincent; Hoad, James; Arif, Mehreen; Wright, David DI
2015-01-01
Objective To compare foam bubble size and bubble size distribution, stability, and degradation rate of commercially available polidocanol endovenous microfoam (Varithena®) and physician-compounded foams using a number of laboratory tests. Methods Foam properties of polidocanol endovenous microfoam and physician-compounded foams were measured and compared using a glass-plate method and a Sympatec QICPIC image analysis method to measure bubble size and bubble size distribution, Turbiscan™ LAB for foam half time and drainage and a novel biomimetic vein model to measure foam stability. Physician-compounded foams composed of polidocanol and room air, CO2, or mixtures of oxygen and carbon dioxide (O2:CO2) were generated by different methods. Results Polidocanol endovenous microfoam was found to have a narrow bubble size distribution with no large (>500 µm) bubbles. Physician-compounded foams made with the Tessari method had broader bubble size distribution and large bubbles, which have an impact on foam stability. Polidocanol endovenous microfoam had a lower degradation rate than any physician-compounded foams, including foams made using room air (p < 0.035). The same result was obtained at different liquid to gas ratios (1:4 and 1:7) for physician-compounded foams. In all tests performed, CO2 foams were the least stable and different O2:CO2 mixtures had intermediate performance. In the biomimetic vein model, polidocanol endovenous microfoam had the slowest degradation rate and longest calculated dwell time, which represents the length of time the foam is in contact with the vein, almost twice that of physician-compounded foams using room air and eight times better than physician-compounded foams prepared using equivalent gas mixes. Conclusion Bubble size, bubble size distribution and stability of various sclerosing foam formulations show that polidocanol endovenous microfoam results in better overall performance compared with physician-compounded foams. Polidocanol endovenous microfoam offers better stability and cohesive properties in a biomimetic vein model compared to physician-compounded foams. Polidocanol endovenous microfoam, which is indicated in the United States for treatment of great saphenous vein system incompetence, provides clinicians with a consistent product with enhanced handling properties. PMID:26036246
Benefits of polidocanol endovenous microfoam (Varithena®) compared with physician-compounded foams.
Carugo, Dario; Ankrett, Dyan N; Zhao, Xuefeng; Zhang, Xunli; Hill, Martyn; O'Byrne, Vincent; Hoad, James; Arif, Mehreen; Wright, David D I; Lewis, Andrew L
2016-05-01
To compare foam bubble size and bubble size distribution, stability, and degradation rate of commercially available polidocanol endovenous microfoam (Varithena®) and physician-compounded foams using a number of laboratory tests. Foam properties of polidocanol endovenous microfoam and physician-compounded foams were measured and compared using a glass-plate method and a Sympatec QICPIC image analysis method to measure bubble size and bubble size distribution, Turbiscan™ LAB for foam half time and drainage and a novel biomimetic vein model to measure foam stability. Physician-compounded foams composed of polidocanol and room air, CO2, or mixtures of oxygen and carbon dioxide (O2:CO2) were generated by different methods. Polidocanol endovenous microfoam was found to have a narrow bubble size distribution with no large (>500 µm) bubbles. Physician-compounded foams made with the Tessari method had broader bubble size distribution and large bubbles, which have an impact on foam stability. Polidocanol endovenous microfoam had a lower degradation rate than any physician-compounded foams, including foams made using room air (p < 0.035). The same result was obtained at different liquid to gas ratios (1:4 and 1:7) for physician-compounded foams. In all tests performed, CO2 foams were the least stable and different O2:CO2 mixtures had intermediate performance. In the biomimetic vein model, polidocanol endovenous microfoam had the slowest degradation rate and longest calculated dwell time, which represents the length of time the foam is in contact with the vein, almost twice that of physician-compounded foams using room air and eight times better than physician-compounded foams prepared using equivalent gas mixes. Bubble size, bubble size distribution and stability of various sclerosing foam formulations show that polidocanol endovenous microfoam results in better overall performance compared with physician-compounded foams. Polidocanol endovenous microfoam offers better stability and cohesive properties in a biomimetic vein model compared to physician-compounded foams. Polidocanol endovenous microfoam, which is indicated in the United States for treatment of great saphenous vein system incompetence, provides clinicians with a consistent product with enhanced handling properties. © The Author(s) 2015.
Wilson, Thomas S.; Bearinger, Jane P.
2017-08-29
New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.
Wilson, Thomas S.; Bearinger, Jane P.
2015-06-09
New shape memory polymer compositions, methods for synthesizing new shape memory polymers, and apparatus comprising an actuator and a shape memory polymer wherein the shape memory polymer comprises at least a portion of the actuator. A shape memory polymer comprising a polymer composition which physically forms a network structure wherein the polymer composition has shape-memory behavior and can be formed into a permanent primary shape, re-formed into a stable secondary shape, and controllably actuated to recover the permanent primary shape. Polymers have optimal aliphatic network structures due to minimization of dangling chains by using monomers that are symmetrical and that have matching amine and hydroxyl groups providing polymers and polymer foams with clarity, tight (narrow temperature range) single transitions, and high shape recovery and recovery force that are especially useful for implanting in the human body.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1982-06-01
The objective of this study is to assess the effectiveness of air sprays and foam systems for dust control on longwall double-drum shearer faces. Laboratory testing has been conducted using foam systems and promising results have been obtained. Upon Bureau approval, underground testing will be scheduled to assess the effectiveness of foam systems under actual operating conditions. Laboratory testing of air sprays is being conducted at present. This report presents the results of the laboratory testing of foam systems. Specifically, the results obtained on the evaluation of selected foaming agents are presented, the feasibility investigation of flushing foam through themore » shearer-drum are demonstrated, and conceptual layout of the foam system on the shearer is discussed. The laboratory investigation of the selected foaming agents reveal that the Onyx Microfoam, Onyx Maprosyl and DeTer Microfoam foaming agents have higher expansion ratios compared to the others tested. Flushing foam through the shearer drum is entirely feasible and could be a viable technique for dust suppression on longwall faces.« less
Ocean foam generation and modeling
NASA Technical Reports Server (NTRS)
Porter, R. A.; Bechis, K. P.
1976-01-01
A laboratory investigation was conducted to determine the physical and microwave properties of ocean foam. Special foam generators were designed and fabricated, using porous glass sheets, known as glass frits, as the principal element. The glass frit was sealed into a water-tight vertical box, a few centimeters from the bottom. Compressed air, applied to the lower chamber, created ocean foam from sea water lying on the frit. Foam heights of 30 cm were readily achieved, with relatively low air pressures. Special photographic techniques and analytical procedures were employed to determine foam bubble size distributions. In addition, the percentage water content of ocean foam was determined with the aid of a particulate sampling procedure. A glass frit foam generator, with pore diameters in the range 70 - 100 micrometers, produced foam with bubble distributions very similar to those found on the surface of natural ocean foam patches.
NASA Astrophysics Data System (ADS)
Haryanto, B.; Chang, C. H.; Kuo, A. T.; Siswarni, M. Z.; Sinaga, T. M. A.
2018-02-01
In this study, the effect of the coffee colloidal particle and Cd ion contaminant on the foam capacity and stability of sodium dodecyl sulfate (SDS) solution was investigated. The foam was generated by using a foam generator. The foam capacity of SDS was first evaluated at different concentrations. After the foam capacity reaching a constant value, the foam stability was then measured by flowing to a column. The results showed that the presence the coffee colloidal particles or Cd ions in the solution would decrease the foam capacity and stability of SDS. In addition, the decreased foam capacity and stability was more pronounced in the presence of coffee colloidal particles than Cd ions. The colloidal particles may have stronger interaction with SDS and thus reduce the formation of the foam.