Science.gov

Sample records for acoustic measurements obtained

  1. Acoustic resolution photoacoustic Doppler flowmetry: practical considerations for obtaining accurate measurements of blood flow

    NASA Astrophysics Data System (ADS)

    Brunker, J.; Beard, P.

    2014-03-01

    An assessment has been made of various experimental factors affecting the accuracy of flow velocities measured using a pulsed time correlation photoacoustic Doppler technique. In this method, Doppler time shifts are quantified via crosscorrelation of pairs of photoacoustic waveforms generated in moving absorbers using pairs of laser light pulses, and the photoacoustic waves are detected using an ultrasound transducer. The acoustic resolution mode is employed by using the transducer focal width, rather than the large illuminated volume, to define the lateral spatial resolution. This enables penetration depths of several millimetres or centimetres, unlike methods using the optical resolution mode, which limits the maximum penetration depth to approximately 1 mm. In the acoustic resolution mode, it is difficult to detect time shifts in highly concentrated suspensions of flowing absorbers, such as red blood cell suspensions and whole blood, and this challenge supposedly arises because of the lack of spatial heterogeneity. However, by assessing the effect of different absorption coefficients and tube diameters, we offer an alternative explanation relating to light attenuation and parabolic flow. We also demonstrate a new signal processing method that surmounts the previous problem of measurement under-reading. This method is a form of signal range gating and enables mapping of the flow velocity profile across the tube as well as measurement of the average flow velocity. We show that, using our signal processing scheme, it is possible to measure the flow of whole blood using a relatively low frequency detector. This important finding paves the way for application of the technique to measurements of blood flow several centimetres deep in living tissue.

  2. Measuring acoustic habitats.

    PubMed

    Merchant, Nathan D; Fristrup, Kurt M; Johnson, Mark P; Tyack, Peter L; Witt, Matthew J; Blondel, Philippe; Parks, Susan E

    2015-03-01

    1. Many organisms depend on sound for communication, predator/prey detection and navigation. The acoustic environment can therefore play an important role in ecosystem dynamics and evolution. A growing number of studies are documenting acoustic habitats and their influences on animal development, behaviour, physiology and spatial ecology, which has led to increasing demand for passive acoustic monitoring (PAM) expertise in the life sciences. However, as yet, there has been no synthesis of data processing methods for acoustic habitat monitoring, which presents an unnecessary obstacle to would-be PAM analysts. 2. Here, we review the signal processing techniques needed to produce calibrated measurements of terrestrial and aquatic acoustic habitats. We include a supplemental tutorial and template computer codes in matlab and r, which give detailed guidance on how to produce calibrated spectrograms and statistical analyses of sound levels. Key metrics and terminology for the characterisation of biotic, abiotic and anthropogenic sound are covered, and their application to relevant monitoring scenarios is illustrated through example data sets. To inform study design and hardware selection, we also include an up-to-date overview of terrestrial and aquatic PAM instruments. 3. Monitoring of acoustic habitats at large spatiotemporal scales is becoming possible through recent advances in PAM technology. This will enhance our understanding of the role of sound in the spatial ecology of acoustically sensitive species and inform spatial planning to mitigate the rising influence of anthropogenic noise in these ecosystems. As we demonstrate in this work, progress in these areas will depend upon the application of consistent and appropriate PAM methodologies.

  3. Measuring acoustic habitats

    PubMed Central

    Merchant, Nathan D; Fristrup, Kurt M; Johnson, Mark P; Tyack, Peter L; Witt, Matthew J; Blondel, Philippe; Parks, Susan E

    2015-01-01

    1. Many organisms depend on sound for communication, predator/prey detection and navigation. The acoustic environment can therefore play an important role in ecosystem dynamics and evolution. A growing number of studies are documenting acoustic habitats and their influences on animal development, behaviour, physiology and spatial ecology, which has led to increasing demand for passive acoustic monitoring (PAM) expertise in the life sciences. However, as yet, there has been no synthesis of data processing methods for acoustic habitat monitoring, which presents an unnecessary obstacle to would-be PAM analysts. 2. Here, we review the signal processing techniques needed to produce calibrated measurements of terrestrial and aquatic acoustic habitats. We include a supplemental tutorial and template computer codes in matlab and r, which give detailed guidance on how to produce calibrated spectrograms and statistical analyses of sound levels. Key metrics and terminology for the characterisation of biotic, abiotic and anthropogenic sound are covered, and their application to relevant monitoring scenarios is illustrated through example data sets. To inform study design and hardware selection, we also include an up-to-date overview of terrestrial and aquatic PAM instruments. 3. Monitoring of acoustic habitats at large spatiotemporal scales is becoming possible through recent advances in PAM technology. This will enhance our understanding of the role of sound in the spatial ecology of acoustically sensitive species and inform spatial planning to mitigate the rising influence of anthropogenic noise in these ecosystems. As we demonstrate in this work, progress in these areas will depend upon the application of consistent and appropriate PAM methodologies. PMID:25954500

  4. Wireless Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Anderson, Paul D.; Dorland, Wade D.

    2005-01-01

    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in "Predicting Rocket or Jet Noise in Real Time" (SSC-00215-1), which appears elsewhere in this issue of NASA Tech Briefs. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro-ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that

  5. Wireless Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Anderson, Paul D.; Dorland, Wade D.; Jolly, Ronald L.

    2007-01-01

    A prototype wireless acoustic measurement system (WAMS) is one of two main subsystems of the Acoustic Prediction/ Measurement Tool, which comprises software, acoustic instrumentation, and electronic hardware combined to afford integrated capabilities for predicting and measuring noise emitted by rocket and jet engines. The other main subsystem is described in the article on page 8. The WAMS includes analog acoustic measurement instrumentation and analog and digital electronic circuitry combined with computer wireless local-area networking to enable (1) measurement of sound-pressure levels at multiple locations in the sound field of an engine under test and (2) recording and processing of the measurement data. At each field location, the measurements are taken by a portable unit, denoted a field station. There are ten field stations, each of which can take two channels of measurements. Each field station is equipped with two instrumentation microphones, a micro- ATX computer, a wireless network adapter, an environmental enclosure, a directional radio antenna, and a battery power supply. The environmental enclosure shields the computer from weather and from extreme acoustically induced vibrations. The power supply is based on a marine-service lead-acid storage battery that has enough capacity to support operation for as long as 10 hours. A desktop computer serves as a control server for the WAMS. The server is connected to a wireless router for communication with the field stations via a wireless local-area network that complies with wireless-network standard 802.11b of the Institute of Electrical and Electronics Engineers. The router and the wireless network adapters are controlled by use of Linux-compatible driver software. The server runs custom Linux software for synchronizing the recording of measurement data in the field stations. The software includes a module that provides an intuitive graphical user interface through which an operator at the control server

  6. Measuring the acoustic response of Helmholtz resonators

    NASA Astrophysics Data System (ADS)

    Monteiro, Martín; Marti, Arturo C.; Vogt, Patrik; Kasper, Lutz; Quarthal, Dominik

    2015-04-01

    Many experiments have been proposed to investigate acoustic phenomena in college and early undergraduate levels, in particular the speed of sound,1-9 by means of different methods, such as time of flight, transit time, or resonance in tubes. In this paper we propose to measure the acoustic response curves of a glass beaker filled with different gases, used as an acoustic resonator. We show that these curves expose many interesting peaks and features, one of which matches the resonance peak predicted for a Helmholtz resonator fairly well, and gives a decent estimate for the speed of sound in some cases. The measures are obtained thanks to the capabilities of smartphones.

  7. Noise correction of turbulent spectra obtained from Acoustic Doppler Velocimeters

    SciTech Connect

    Durgesh, Vibhav; Thomson, Jim; Richmond, Marshall C.; Polagye, Brian

    2014-03-02

    Accurately estimated auto-spectral density functions are essential for characterization of turbulent flows, and they also have applications in computational fluid dynamics modeling, site and inflow characterization for hydrokinetic turbines, and inflow turbulence generation. The Acoustic Doppler Velocimeter (ADV) provides single-point temporally resolved data, that are used to characterize turbulent flows in rivers, seas, and oceans. However, ADV data are susceptible to contamination from various sources, including instrument noise, which is the intrinsic limit to the accuracy of acoustic velocity measurements. Due to the presence of instrument noise, the spectra obtained are altered at high frequencies. The focus of this study is to develop a robust and effective method for accurately estimating auto-spectral density functions from ADV data by reducing or removing the spectral contribution derived from instrument noise. For this purpose, the “Noise Auto-Correlation” (NAC) approach was developed, which exploits the correlation properties of instrument noise to identify and remove its contribution from spectra. The spectra estimated using the NAC approach exhibit increased fidelity and a slope of -5/3 in the inertial range, which is typically observed for turbulent flows. Finally, this study also compares the effectiveness of low-pass Gaussian filters in removing instrument noise with that of the NAC approach. For the data used in this study, both the NAC and Gaussian filter approaches are observed to be capable of removing instrument noise at higher frequencies from the spectra. However, the NAC results are closer to the expected frequency power of -5/3 in the inertial sub-range.

  8. Fundamentals of Acoustics. Psychoacoustics and Hearing. Acoustical Measurements

    NASA Technical Reports Server (NTRS)

    Begault, Durand R.; Ahumada, Al (Technical Monitor)

    1997-01-01

    These are 3 chapters that will appear in a book titled "Building Acoustical Design", edited by Charles Salter. They are designed to introduce the reader to fundamental concepts of acoustics, particularly as they relate to the built environment. "Fundamentals of Acoustics" reviews basic concepts of sound waveform frequency, pressure, and phase. "Psychoacoustics and Hearing" discusses the human interpretation sound pressure as loudness, particularly as a function of frequency. "Acoustic Measurements" gives a simple overview of the time and frequency weightings for sound pressure measurements that are used in acoustical work.

  9. Acoustical Measurement Of Furnace Temperatures

    NASA Technical Reports Server (NTRS)

    Parthasarathy, Shakkottai; Venkateshan, Shakkottai P.

    1989-01-01

    Simple probes withstand severe conditions, yet give spatially-resolved temperature readings. Prototype acoustical system developed to measure temperatures from ambient to 1,800 degree F in such structures as large industrial lime kilns and recovery-boiler furnaces. Pulses of sound reflected from obstructions in sensing tube. Speed of sound and temperature in each segment deduced from travel times of pulses.

  10. Scale Model Thruster Acoustic Measurement Results

    NASA Technical Reports Server (NTRS)

    Kenny, R. Jeremy; Vargas, Magda B.

    2013-01-01

    Subscale rocket acoustic data is used to predict acoustic environments for full scale rockets. Over the last several years acoustic data has been collected during horizontal tests of solid rocket motors. Space Launch System (SLS) Scale Model Acoustic Test (SMAT) was designed to evaluate the acoustics of the SLS vehicle including the liquid engines and solid rocket boosters. SMAT is comprised of liquid thrusters scalable to the Space Shuttle Main engines (SSME) and Rocket Assisted Take Off (RATO) motors scalable to the 5-segment Reusable Solid Rocket Motor (RSTMV). Horizontal testing of the liquid thrusters provided an opportunity to collect acoustic data from liquid thrusters to characterize the acoustic environments. Acoustic data was collected during the horizontal firings of a single thruster and a 4-thruster (Quad) configuration. Presentation scope. Discuss the results of the single and 4-thruster acoustic measurements. Compare the measured acoustic levels of the liquid thrusters to the Solid Rocket Test Motor V - Nozzle 2 (SRTMV-N2).

  11. Characteristics of acoustic gravity waves obtained from Dynasonde data

    NASA Astrophysics Data System (ADS)

    Negrea, Cǎtǎlin; Zabotin, Nikolay; Bullett, Terrence; Fuller-Rowell, Tim; Fang, Tzu-Wei; Codrescu, Mihail

    2016-04-01

    Traveling ionospheric disturbances (TIDs) are ubiquitous in the thermosphere-ionosphere and are often assumed to be caused by acoustic gravity waves (AGWs). This study performs an analysis of the TID and AGW activity above Wallops Island, VA, during October 2013. The variations in electron density and ionospheric tilts obtained with the Dynasonde technique are used as primary indicators of wave activity. The temporal and spectral characteristics of the data are discussed in detail, using also results of the Whole Atmosphere Model (WAM) and the Global Ionosphere Plasmasphere Model (GIP). The full set of propagation parameters (frequency, and the vertical, zonal and meridional wave vector components) of the TIDs is determined over the 160-220 km height range. A test of the self-consistency of these results within the confines of the theoretical AGW dispersion relation is devised. This is applied to a sample data set of 24 October 2013. A remarkable agreement has been achieved for wave periods between 52 and 21 min, for which we can rigorously claim the TIDs are caused by underlying acoustic gravity waves. The Wallops Island Dynasonde can operate for extended periods at a 2 min cadence, allowing determination of the statistical distributions of propagation parameters. A dominant population of TIDs is identified in the frequency band below 1 mHz, and for it, the distributions of the horizontal wavelengths, vertical wavelengths, and horizontal phase speeds are obtained.

  12. Measurement of acoustical characteristics of mosques in Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Abdou, Adel A.

    2003-03-01

    The study of mosque acoustics, with regard to acoustical characteristics, sound quality for speech intelligibility, and other applicable acoustic criteria, has been largely neglected. In this study a background as to why mosques are designed as they are and how mosque design is influenced by worship considerations is given. In the study the acoustical characteristics of typically constructed contemporary mosques in Saudi Arabia have been investigated, employing a well-known impulse response. Extensive field measurements were taken in 21 representative mosques of different sizes and architectural features in order to characterize their acoustical quality and to identify the impact of air conditioning, ceiling fans, and sound reinforcement systems on their acoustics. Objective room-acoustic indicators such as reverberation time (RT) and clarity (C50) were measured. Background noise (BN) was assessed with and without the operation of air conditioning and fans. The speech transmission index (STI) was also evaluated with and without the operation of existing sound reinforcement systems. The existence of acoustical deficiencies was confirmed and quantified. The study, in addition to describing mosque acoustics, compares design goals to results obtained in practice and suggests acoustical target values for mosque design. The results show that acoustical quality in the investigated mosques deviates from optimum conditions when unoccupied, but is much better in the occupied condition.

  13. Measurement of acoustical characteristics of mosques in Saudi Arabia.

    PubMed

    Abdou, Adel A

    2003-03-01

    The study of mosque acoustics, with regard to acoustical characteristics, sound quality for speech intelligibility, and other applicable acoustic criteria, has been largely neglected. In this study a background as to why mosques are designed as they are and how mosque design is influenced by worship considerations is given. In the study the acoustical characteristics of typically constructed contemporary mosques in Saudi Arabia have been investigated, employing a well-known impulse response. Extensive field measurements were taken in 21 representative mosques of different sizes and architectural features in order to characterize their acoustical quality and to identify the impact of air conditioning, ceiling fans, and sound reinforcement systems on their acoustics. Objective room-acoustic indicators such as reverberation time (RT) and clarity (C50) were measured. Background noise (BN) was assessed with and without the operation of air conditioning and fans. The speech transmission index (STI) was also evaluated with and without the operation of existing sound reinforcement systems. The existence of acoustical deficiencies was confirmed and quantified. The study, in addition to describing mosque acoustics, compares design goals to results obtained in practice and suggests acoustical target values for mosque design. The results show that acoustical quality in the investigated mosques deviates from optimum conditions when unoccupied, but is much better in the occupied condition.

  14. Acoustic measurements of articulator motions.

    PubMed

    Schroeder, M R; Strube, H W

    1979-01-01

    Methods for estimating articulatory data from acoustic measurements are reviewed. First, relations between the vocal-tract area function and formant or impedance data are pointed out. Then the possibility of determining a (discretized) area function from the speech signal itself is considered. Finally, we look at the estimation of certain articulatory parameters rather than the area function. By using a regression method, such parameters can even be estimated independently of any vocal-tract model. Results for real-speech data are given.

  15. Acoustic Measurements of Small Solid Rocket Motor

    NASA Technical Reports Server (NTRS)

    Vargas, Magda B.; Kenny, R. Jeremy

    2010-01-01

    Rocket acoustic noise can induce loads and vibration on the vehicle as well as the surrounding structures. Models have been developed to predict these acoustic loads based on scaling existing solid rocket motor data. The NASA Marshall Space Flight Center acoustics team has measured several small solid rocket motors (thrust below 150,000 lbf) to anchor prediction models. This data will provide NASA the capability to predict the acoustic environments and consequent vibro-acoustic response of larger rockets (thrust above 1,000,000 lbf) such as those planned for the NASA Constellation program. This paper presents the methods used to measure acoustic data during the static firing of small solid rocket motors and the trends found in the data.

  16. Measurement of the Q value of an acoustic resonator.

    PubMed

    Biwa, Tetsushi; Ueda, Yuki; Nomura, Hiroshi; Mizutani, Uichiro; Yazaki, Taichi

    2005-08-01

    A cylindrical acoustic resonator was externally driven at the first resonance frequency by a compression driver. The acoustic energy stored in the resonator and the power dissipated per unit time were evaluated through the simultaneous measurements of acoustic pressure and velocity, in order to determine the Q value of the resonator. The resulting Q value, being employed as a measure of the damping in a resonator, was obtained as 36. However, the Q value determined from a frequency response curve known as a conventional technique turned out to be 25, which is 30% less than that obtained in the present method. By further applying these two methods in the case of a resonator having an acoustic load inside, we present an accurate measurement of the Q value of the resonator by making full use of its definition.

  17. Approach to Eliminate Couplant-Effect in Acoustic Nonlinearity Measurements

    SciTech Connect

    Sun, L.; Kulkarni, S. S.; Achenbach, J. D.; Krishnaswamy, S.

    2006-03-06

    An approach to eliminate couplant-effect in acoustic nonlinearity measurements for fatigued components is proposed in this paper. Measurements are performed on a fatigued steel 4340 specimen using both the conventional and proposed techniques. It is observed that the coefficients of variation of the nonlinearity parameter obtained using the proposed technique is approximately half of that obtained using the conventional technique.

  18. Flight Acoustics Measurement Techniques and Applications

    NASA Technical Reports Server (NTRS)

    Preisser, J. S.; Marcolini, M. A.

    1998-01-01

    Careful consideration must be given to data acquisition and analysis techniques in the design of experiments for the measurement of noise generated by flight vehicles. Although noise measurement locations and data reduction procedures are specified for aircraft certification by FAA and ICAO directives, for example, there are virtually no established procedures for aircraft noise measurement for other purposes. To optimize the quality and quantity of information obtained in a flight acoustics experiment, microphone layout, data acquisition, and analysis must be tailored to the specific test objective. This paper will review flight acoustics technology at NASA Langley Research Center developed over the past decade. In particular, the paper will focus on flight experiments performed for three diverse objectives: (1) research applications, such as noise prediction code validation, (2) noise impact modeling, and (3) noise abatement flight procedures. To best achieve these diverse objectives, different deployments of microphone systems on the ground are required, and different data analysis techniques are needed. In all cases, accurate positioning of the aircraft synchronized in time with the data recording is necessary. However, there are some restrictions on flight operations unique to each case for the methods to properly work.

  19. Comparison of acoustic and mechanical excitation for modal response measurements

    NASA Astrophysics Data System (ADS)

    Musson, B. G.; Stevens, J. R.

    An acoustic field is examined as an alternate to mechanical excitation of a test specimen to measure modal response. A square, flat plate with clamped edges is used because classical analytical solutions to its modal analysis are readily available. A small hammer with a built-in force transducer is used to mechanically excite the plate, and the plate is excited with electro-pneumatic acoustic drivers coupled to a progressive-wave test fixture. Band limited random amplitude acoustic waves over a frequency range of 50 to 1000 Hz are applied at grazing incidence to the plate. The acoustic field is characterized and a microphone at a single fixed position is used to provide the reference forcing function. Results are compared with the analytical solutions and with the mechanically excited results. Conclusions are presented concerning the equivalence of acoustic and mechanical excitation for obtaining modal response.

  20. Measurement of the acoustic reflex without a pressure seal.

    PubMed

    Surr, R K; Schuchman, G I

    1976-03-01

    Obtaining a hermetic seal in the external auditory canal is often a major obstacle in impedance audiometry. In the present study, the acoustic reflex threshold was determined for three groups of subjects, first with and then without a pressure-tight seal. It was found that for subjects with normal hearing or sensorineural hearing loss and normal tympanograms, 96% of the measurements obtained without a pressure seal were within 5 dB of those obtained with a seal. Among the subjects who exhibited negative middle ear pressure, the acoustic reflex could be measured consistently at the point of maximum compliance, while no response was observed without a pressure seal.

  1. Acoustic Impedance Measurement for Underground Surfaces.

    NASA Astrophysics Data System (ADS)

    Cockcroft, Paul William

    Available from UMI in association with The British Library. Requires signed TDF. This thesis investigates the measurement of acoustic impedance for surfaces likely to be found in underground coal mines. By introducing the concepts of industrial noise, the effects of noise on the ear and relevant legislation the need for the protection of workers can be appreciated. Representative acoustic impedance values are vital as input for existing computer models that predict sound levels in various underground environments. These enable the mining engineer to predict the noise level at any point within a mine in the vicinity of noisy machinery. The concepts of acoustic intensity and acoustic impedance are investigated and different acoustic impedance measurement techniques are detailed. The possible use of either an impedance tube or an intensity meter for these kinds of measurements are suggested. The problems with acoustic intensity and acoustic impedance measurements are discussed with reference to the restraints that an underground environment imposes on any measurement technique. The impedance tube method for work in an acoustics laboratory is shown and the theory explained, accompanied by a few representative results. The use of a Metravib intensity meter in a soundproof chamber to gain impedance values is explained in detail. The accompanying software for the analysis of the two measured pressure signals is shown as well as the actual results for a variety of test surfaces. The use of a Nagra IV-SJ tape recorder is investigated to determine the effect of recording on the measurement and subsequent analysis of the input signals, particularly with reference to the phase difference introduced between the two simultaneous pressure signals. The subsequent use of a Norwegian Electronic intensity meter, including a proposal for underground work, is shown along with results for tests completed with this piece of equipment. Finally, recommendations are made on how to link up

  2. Acoustic Measurements for Small Solid Rocket Motors

    NASA Technical Reports Server (NTRS)

    Vargas, Magda B.; Kenny, R. Jeremy

    2010-01-01

    Models have been developed to predict large solid rocket motor acoustic loads based on the scaling of small solid rocket motors. MSFC has measured several small solid rocket motors in horizontal and launch configurations to anchor these models. Solid Rocket Test Motor (SRTM) has ballistics similar to the Reusable Solid Rocket Motor (RSRM) therefore a good choice for acoustic scaling. Acoustic measurements were collected during the test firing of the Insulation Configuration Extended Length (ICXL) 7,6, and 8 (in firing order) in order to compare to RSRM horizontal firing data. The scope of this presentation includes: Acoustic test procedures and instrumentation implemented during the three SRTM firings and Data analysis method and general trends observed in the data.

  3. Reflectance measurement validation using acoustic horns

    PubMed Central

    Rasetshwane, Daniel M.; Neely, Stephen T.

    2015-01-01

    Variability in wideband acoustic reflectance (and absorbance) measurements adversely affects the clinical utility of reflectance for diagnosis of middle-ear disorders. A reflectance standard would encourage consistency across different measurement systems and help identify calibration related issues. Theoretical equations exist for the reflectance of finite-length exponential, conical, and parabolic acoustic horns. Reflectance measurements were repeatedly made in each of these three horn shapes and the results were compared to the corresponding theoretical reflectance. A method is described of adjusting acoustic impedance measurements to compensate for spreading of the wave front that propagates from the small diameter sound port of the probe to the larger diameter of the acoustic cavity. Agreement between measured and theoretical reflectance was less than 1 dB at most frequencies in the range from 0.2 to 10 kHz. Pearson correlation coefficients were greater than 0.95 between measured and theoretical time-domain reflectance within the flare region of the horns. The agreement suggests that the distributed reflectance of acoustic horns may be useful for validating reflectance measurements made in human ear canals; however, refinements to reflectance measurement methods may still be needed. PMID:26520306

  4. Reflectance measurement validation using acoustic horns.

    PubMed

    Rasetshwane, Daniel M; Neely, Stephen T

    2015-10-01

    Variability in wideband acoustic reflectance (and absorbance) measurements adversely affects the clinical utility of reflectance for diagnosis of middle-ear disorders. A reflectance standard would encourage consistency across different measurement systems and help identify calibration related issues. Theoretical equations exist for the reflectance of finite-length exponential, conical, and parabolic acoustic horns. Reflectance measurements were repeatedly made in each of these three horn shapes and the results were compared to the corresponding theoretical reflectance. A method is described of adjusting acoustic impedance measurements to compensate for spreading of the wave front that propagates from the small diameter sound port of the probe to the larger diameter of the acoustic cavity. Agreement between measured and theoretical reflectance was less than 1 dB at most frequencies in the range from 0.2 to 10 kHz. Pearson correlation coefficients were greater than 0.95 between measured and theoretical time-domain reflectance within the flare region of the horns. The agreement suggests that the distributed reflectance of acoustic horns may be useful for validating reflectance measurements made in human ear canals; however, refinements to reflectance measurement methods may still be needed.

  5. Measuring Acoustic Nonlinearity by Collinear Mixing Waves

    NASA Astrophysics Data System (ADS)

    Liu, M.; Tang, G.; Jacobs, L. J.; Qu, J.

    2011-06-01

    It is well known that the acoustic nonlinearity parameter β is correlated to fatigue damage in metallic materials. Various methods have been developed to measure β. One of the most often used methods is the harmonic generation technique, in which β is obtained by measuring the magnitude of the second order harmonic waves. An inherent weakness of this method is the difficulty in distinguishing material nonlinearity from the nonlinearity of the measurement system. In this paper, we demonstrate the possibility of using collinear mixing waves to measure β. The wave mixing method is based on the interaction between two incident waves in a nonlinear medium. Under certain conditions, such interactions generate a third wave of different frequency. This generated third wave is also called resonant wave, because its amplitude is unbounded if the medium has no attenuation. Such resonant waves are less sensitive to the nonlinearity of the measurement system, and have the potential to identify the source location of the nonlinearity. In this work, we used a longitudinal wave and a shear wave as the incident waves. The resonant shear wave is measured experimentally on samples made of aluminum and steel, respectively. Numerical simulations of the tests were also performed using a finite difference method.

  6. Acoustic Doppler discharge-measurement system

    USGS Publications Warehouse

    Simpson, Michael R.; Oltmann, Richard N.; ,

    1990-01-01

    A discharge-measurement system that uses a vessel-mounted acoustic Doppler current profiler has been developed and tested by the U.S. Geological Survey. Discharge measurements using the system require a fraction of the time needed for conventional current-meter discharge measurements and do not require shore-based navigational aids or tag lines for positioning the vessel.

  7. Measuring aeolian sand transport using acoustic sensors

    NASA Astrophysics Data System (ADS)

    Poortinga, Ate; van Rheenen, Hans; Ellis, Jean T.; Sherman, Douglas J.

    2015-03-01

    Acoustic sensors are frequently used to measure aeolian saltation. Different approaches are used to process the signals from these instruments. The goal of this paper is to describe and discuss a method to measure aeolian saltation with acoustic sensors. In a laboratory experiment, we measured the output from an advanced signal processing scheme on the circuit board of the saltiphone. We use a software implementation of this processing scheme to re-analyse data from four miniphones obtained during a field experiment. It is shown that a set of filters remove background noise outside the frequency spectrum of aeolian saltation (at 8 kHz), whereas signals within this frequency spectrum are amplified. The resulting analogue signal is a proxy of the energy. Using an AC pulse convertor, this signal can be converted into a digital and analogue count signal or an analogue energy signal, using a rectifier and integrator. Spatio-temporal correlation between field deployed miniphones increases by using longer integration times for signal processing. To quantify aeolian grain impact, it is suggested to use the analogue energy output, as this mode is able to detect changes in frequency and amplitude. The analogue and digital count signals are able to detect an increase in frequency, but are not able to detect an increase in signal amplitude. We propose a two-stage calibration scheme consisting of (1) a factory calibration, to set the frequency spectrum of the sensor and (2) a standardized drop-test conducted before and after the experiment to evaluate the response of the sensor.

  8. Drag Measurements of Porous Plate Acoustic Liners

    NASA Technical Reports Server (NTRS)

    Wolter, John D.

    2005-01-01

    This paper presents the results of direct drag measurements on a variety of porous plate acoustic liners. The existing literature describes numerous studies of drag on porous walls with injection or suction, but relatively few of drag on porous plates with neither injection nor suction. Furthermore, the porosity of the porous plate in existing studies is much lower than typically used in acoustic liners. In the present work, the acoustic liners consisted of a perforated face sheet covering a bulk acoustic absorber material. Factors that were varied in the experiment were hole diameter, hole pattern, face sheet thickness, bulk material type, and size of the gap (if any) between the face sheet and the absorber material.

  9. Hydrocarbon saturation determination using acoustic velocities obtained through casing

    DOEpatents

    Moos, Daniel

    2010-03-09

    Compressional and shear velocities of earth formations are measured through casing. The determined compressional and shear velocities are used in a two component mixing model to provides improved quantitative values for the solid, the dry frame, and the pore compressibility. These are used in determination of hydrocarbon saturation.

  10. Hybrid system for magnetic and acoustic measurement.

    PubMed

    Bruno, A C; Baffa, O; Carneiro, A O

    2009-01-01

    In order to improve the spatial resolution of Biosusceptometry of Alternate Current (BAC), we are suggesting the coupling of a Doppler ultrasonic transducer with the BAC system. The Doppler transducer obtains information from the vibration of ferromagnetic particles immersed in a visco-elastic medium when it is excited by an alternating magnetic field. In this case, the same magnetic particles used as contrast for susceptometric measurement also will work as contrast for the Doppler measurement. In this work, we present the characterization of the hybrid system for susceptometric and acoustic measurements simultaneously. It was observed that the susceptometric and Doppler ultrasound signal have the same profile and maximum amplitude for frequency of magnetizing field about 200 Hz. When using ferrite particles as magnetic contrast mixed with yogurt as based material, the susceptometric and Doppler measurement have sensitivity for concentration of particles as low as 1%. The sensitivity of the Doppler is dependent of the gradient of magnetic field over the sample. In this work, the magnetic field 5 cm far from the face of the transducer was 70 microT/volts.

  11. Measuring acoustic properties of materials and jet nozzles

    NASA Technical Reports Server (NTRS)

    Dean, P. D.; Plumblee, H. E.; Salikuddin, M.

    1980-01-01

    Method measures acoustic properties of sound-absorbent materials and jet-nozzle system. Advantages of impulse method over other methods are that test time and complication are reduced. Results obtained from impulse method have been compared with those from existing methods, both experimental and theoretical, and show excellent agreement.

  12. Acoustic Measurement of Potato Cannon Velocity

    ERIC Educational Resources Information Center

    Courtney, Michael; Courtney, Amy

    2007-01-01

    Potato cannon velocity can be measured with a digitized microphone signal. A microphone is attached to the potato cannon muzzle, and a potato is fired at an aluminum target about 10 m away. Flight time can be determined from the acoustic waveform by subtracting the time in the barrel and time for sound to return from the target. The potato…

  13. Acoustical measurements in ancient Roman theatres

    NASA Astrophysics Data System (ADS)

    Farnetani, Andrea; Fausti, Patrizio; Pompoli, Roberto; Prodi, Nicola

    2004-05-01

    The Greek and Roman theatres are among the most precious and spectacular items of cultural heritage in the Mediterranean countries. The theatres are famous not only for their impressive architecture, but also for the acoustic qualities. For this reason it is important to consider these theatres as an acoustical heritage and to study their sound field. Within the activities of the ERATO (identification Evaluation and Revival of the Acoustical heritage of ancient Theatres and Odea) project, acoustical measurements were taken in well-preserved ancient Roman theatres at Aspendos (Turkey) and Jerash (Jordan). Roman theatres have an impressive stage building that forms a back wall in the orchestra area, and it was found that, from the analysis of the acoustical parameters, the reverberation time (e.g., 1.7 s at middle frequencies in the theatre of Aspendos) is quite long compared not only with other open-space theatres but also with closed spaces. Contrary to modern halls the clarity is high and this fact, together with a low sound level in most of the seats, gives the sound field a unique character.

  14. High-frequency attenuation measurements using an acoustic microscope.

    PubMed

    Gracewski, S M; Waag, R C; Schenk, E A

    1988-06-01

    An acoustic microscope was used to measure excess attenuation of aqueous solutions of sugars and proteins at 1.0 GHz. Interference pattern spacing and peak amplitude reduction of V(z) curves, obtained with these solutions as the acoustic microscope coupling liquid, were related to the solution wavespeed and attenuation, respectively. Consistent with published results for lower frequencies, solutions with molecular weight greater than 10,000 had a higher specific absorption than those with a molecular weight less than 1000 and within these two molecular weight ranges specific absorption was independent of concentration.

  15. Acoustic impedance measurements of pulse tube refrigerators

    NASA Astrophysics Data System (ADS)

    Iwase, Takashi; Biwa, Tetsushi; Yazaki, Taichi

    2010-02-01

    Complex acoustic impedance is determined in a prototype refrigerator that can mimic orifice-type, inertance-type, and double inlet-type pulse tube refrigerators from simultaneous measurements of pressure and velocity oscillations at the cold end. The impedance measurements revealed the means by which the oscillatory flow condition in the basic pulse tube refrigerator is improved by additional components such as a valve and a tank. The working mechanism of pulse tube refrigerators is explained based on an electrical circuit analogy.

  16. An Expendable Source for Measuring Shallow Water Acoustic Propagation and Geo-Acoustic Bottom Properties

    DTIC Science & Technology

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. An Expendable Source for Measuring Shallow Water Acoustic ...Propagation and Geo- Acoustic Bottom Properties Harry A DeFerrari RSMAS – University of Miami 4600 Rickenbacker Causeway Miami FL. 33149...broadband source is being developed that transmits high gain m-sequence to clandestinly measure pulse response of shallow water acoustic propagation

  17. Measuring Acoustic Noise around Kahoolawe Island.

    DTIC Science & Technology

    1981-10-01

    NAVAL OCEAN SYSTEMS CENTER SAN DIEGO, CALIFORNIA 92152 C y 2 .V ANAVAL OCEAN SYSTEMS CENTER, SAN DIEGO, CA 92152 AN ACTIV IT Y OF THE NAVAL... Ocean Systems Center (NOSC), Code 512, on NSAP Project TH-1 -80, "Measurement of Acoustic Noise Around Kahoolawe". CDR J. W. Carlmark, USN, COMTHIRDFLT N...Bioacoustics & Bionics Division Biosciences Department ,or -.. .- ?---1 1 : ’" " "’ .... .-j UNCLASSIFIED SECURITY CLASSIFICATION OF THIS PAGE (When Data

  18. Acoustic measurements of air entrainment by breaking waves

    NASA Astrophysics Data System (ADS)

    Terrill, Eric James

    1998-11-01

    Wave breaking at the surface of the ocean plays an important role in air-sea interaction processes. Bubbles entrained by breaking waves not only enhance the transfer of atmospheric gases to the ocean, but also modify the phase speed and attenuation of acoustic waves propagating through the bubbly medium. The development of acoustic instruments to measure bubbles and the results obtained from a number of field and laboratory experiments are presented. The first part of this dissertation addresses sound speed measurements made in the North Atlantic as part of the Acoustic Surface Reverberation Experiment (ASREX). An autonomous buoy system that directly measures the sound speed in the surface wave layer was developed. Data obtained with the instrument spanned several storm cycles with wind speeds and significant wave heights reaching 20 m/s and 8 m, respectively. The use of Wood's relation (1946) allows the calculation of the void fraction of air based on the low-frequency sound speed measurements. The highly variable near-surface sound speed/void fraction field is analyzed with respect to wind and surface wave- breaking parameters. The second part of this dissertation presents the development of a broadband acoustic technique which simultaneously measures the phase speed and attenuation at acoustic frequencies ranging from 4-100 kHz. The acoustic data is inverted for the size distribution of bubbles using algorithms that are based upon the physics of sound propagation through a bubbly mixture. This acoustic technique was evaluated in the large wave channel at the Hydraulics Laboratory, Scripps Institution of Oceanography, using mechanically generated breaking waves in seawater. Field measurements of bubble concentrations that result from wave breaking were made in both shallow water off Scripps Pier, California and in deep water near Point Conception, California using the broadband technique. Significant variability is observed in the bubble field, characterized by

  19. Measuring acoustic emissions in an avalanche slope

    NASA Astrophysics Data System (ADS)

    Reiweger, Ingrid; Schweizer, Jürg

    2014-05-01

    Measurements of acoustic emissions are a common technique for monitoring damage and predicting imminent failure of a material. Within natural hazards it has already been used to successfully predict the break-off of a hanging glacier. To explore the applicability of the acoustic emission (AE) technique for avalanche prediction, we installed two acoustic sensors (with 30 kHz and 60 kHz resonance frequency) in an avalanche prone slope at the Mittelgrat in the Parsenn ski area above Davos, Switzerland. The slope is north-east facing, frequently wind loaded, and approximately 35° steep. The AE signals - in particular the event energy and waiting time distributions - were compared with slope stability. The latter was determined by observing avalanche activity. The results of two winter's measurements yielded that the exponent β of the inverse cumulative distribution of event energy showed a significant drop (from a value of 3.5 to roughly 2.5) at very unstable conditions, i.e. on the three days during our measurement periods when spontaneous avalanches released on our study slope.

  20. Acoustic Doppler velocimeter-induced acoustic streaming and its implications for measurement

    NASA Astrophysics Data System (ADS)

    Poindexter, C. M.; Rusello, P. J.; Variano, E. A.

    2011-05-01

    The acoustic Doppler velocimeter (ADV) is widely used for the characterization of fluid flow. Secondary flows ("acoustic streaming") generated by the ADV's acoustic pulses may affect the accuracy of measurements in experiments with small velocities. We assessed the impact of acoustic streaming on flow measurement using particle image velocimetry. The probes of two different ADVs were successively mounted in a tank of quiescent water. The probes' ultrasound emitters were aligned with a laser light sheet. Observed flow was primarily in the axial direction, accelerating from the ultrasound emitter and peaking within centimeters of the velocimeter sampling volume before dropping off. We measured the dependence of acoustic streaming velocity on ADV configuration, finding that different settings induce streaming ranging from negligible to more than 2.0 cm s-1. From these results, we describe cases where acoustic streaming affects velocity measurements and also cases where ADVs accurately measure their own acoustic streaming.

  1. Measurements of acoustic sources in motion

    NASA Technical Reports Server (NTRS)

    Maestrello, L.; Norum, T. D.

    1978-01-01

    Results of the far-field pressures measured from three different types of moving sources are presented. These acoustic sources consist of a point monopole, a small model jet, and an aircraft. Results for the pressure time history produced by the point source show good agreement with those predicted analytically. Both actual and simulated forward motion of the model jet show reductions in noise levels with forward speed at all angles between the source and observer. Measurement with the aircraft over both an anechoic floor and over the ground yields a method for evaluating the transfer function for ground reflections at various angles between the moving aircraft and measurement position.

  2. Relationship between acoustic measures and speech naturalness ratings in Parkinson's disease: A within-speaker approach.

    PubMed

    Klopfenstein, Marie

    2015-01-01

    This study investigated the acoustic basis of across-utterance, within-speaker variation in speech naturalness for four speakers with dysarthria secondary to Parkinson's disease (PD). Speakers read sentences and produced spontaneous speech. Acoustic measures of fundamental frequency, phrase-final syllable lengthening, intensity and speech rate were obtained. A group of listeners judged speech naturalness using a nine-point Likert scale. Relationships between judgements of speech naturalness and acoustic measures were determined for individual speakers with PD. Relationships among acoustic measures also were quantified. Despite variability between speakers, measures of mean F0, intensity range, articulation rate, average syllable duration, duration of final syllables, vocalic nucleus length of final unstressed syllables and pitch accent of final syllables emerged as possible acoustic variables contributing to within-speaker variations in speech naturalness. Results suggest that acoustic measures correlate with speech naturalness, but in dysarthric speech they depend on the speaker due to the within-speaker variation in speech impairment.

  3. Acoustic measuring techniques for suspended sediment

    NASA Astrophysics Data System (ADS)

    Gruber, P.; Felix, D.; Storti, G.; Lattuada, M.; Fleckenstein, P.; Deschwanden, F.

    2016-11-01

    Acoustic signals can be used in various ways for suspended sediment monitoring. One possibility which lends itself particularly well in the context of hydropower plants (HPPs), is to use installations for acoustic discharge measurement (ADM). Such installations already exist at waterways of many HPPs. Similar to certain turbidimeters, the attenuation of the forward scattered signal travelling through the water-sediment mixture is correlated with suspended sediment concentration (SSC). This correlation can be based on reference SSCs, e.g. from gravimetric analyses of bottle samples. Without the need of additional sensors and practically maintenance-free, this method is used successfully in the HPP Fieschertal to warn the HPP operator of high SSC to prevent excessive turbine abrasion. Acoustic methods and systems that allow for estimating both SSC and particle size distribution (PSD) are under development. The simultaneous determination of SSC and PSD is not possible using a single frequency. Therefore, multi-frequency approaches are investigated for generally scattered signals. When backscattered signals are used, a stronger frequency dependency can be exploited. However, the reliable simultaneous determination of particle size (and distribution) and concentration is still a major challenge due to a low signal-to-noise ratio and an ill- posed problem of estimating concentration and size from recorded signals. The optimal setup configuration (angles, frequencies) for such a system is not unique and further investigations are recommended.

  4. The application of acoustic emission technique to fatigue crack measurement. [in aluminum alloys

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Davis, W. T.; Crews, J. H., Jr.

    1974-01-01

    The applicability of acoustic emission technique to measure fatigue cracks in aluminum alloy specimens was investigated. There are several variables, such as the metallurgical and the physical treatment of the specimen, that can affect the level of acoustic activity of a fatigue specimen. It is therefore recommended that the acoustic emission technique be supplemented by other nondestructive evaluation methods to obtain quantitative data on crack growth.

  5. Acoustics measurements in normal jet impingement

    NASA Technical Reports Server (NTRS)

    Kleis, S. J.

    1977-01-01

    The dependence of far field acoustic measurements for a uniform jet on nozzle to plate spacing for small dimensionless spacings (h/d - 0.75 to 3.0) was investigated. Spectra from a real time analyzer were read and processed by an HP 2116 minicomputer in on-line mode. Similar data was generated for a fully developed pipe flow exit condition jet to compare with other investigations. The data base for normal jet impingement was extended to smaller values of nozzle to plate spacing. The effects of slight noise heating (30 deg rise) of the jet on the far field noise produced by the impinging jet are demonstrated.

  6. Relationship between acoustic measures and judgments of intelligibility in Parkinson's disease: a within-speaker approach.

    PubMed

    Feenaughty, Lynda; Tjaden, Kris; Sussman, Joan

    2014-11-01

    This study investigated the acoustic basis of within-speaker, across-utterance variation in sentence intelligibility for 12 speakers with dysarthria secondary to Parkinson's disease (PD). Acoustic measures were also obtained for 12 healthy controls for comparison to speakers with PD. Speakers read sentences using their typical speech style. Acoustic measures of speech rate, articulatory rate, fundamental frequency, sound pressure level and F2 interquartile range (F2 IQR) were obtained. A group of listeners judged sentence intelligibility using a computerized visual-analog scale. Relationships between judgments of intelligibility and acoustic measures were determined for individual speakers with PD. Relationships among acoustic measures were also quantified. Although considerable variability was noted, articulatory rate, fundamental frequency and F2 IQR were most frequently associated with within-speaker variation in sentence intelligibility. Results suggest that diversity among speakers with PD should be considered when interpreting results from group analyses.

  7. Precision of Four Acoustic Bone Measurement Devices

    NASA Technical Reports Server (NTRS)

    Miller, Christopher; Rianon, Nahid; Feiveson, Alan; Shackelford, Linda; LeBlanc, Adrian

    2000-01-01

    Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Bone Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift. The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values (less than 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

  8. Precision of Four Acoustic Bone Measurement Devices

    NASA Technical Reports Server (NTRS)

    Miller, Christopher; Feiveson, Alan H.; Shackelford, Linda; Rianon, Nahida; LeBlanc, Adrian

    2000-01-01

    Though many studies have quantified the precision of various acoustic bone measurement devices, it is difficult to directly compare the results among the studies, because they used disparate subject pools, did not specify the estimation methodology, or did not use consistent definitions for various precision characteristics. In this study, we used a repeated measures design protocol to directly determine the precision characteristics of four acoustic bone measurement devices: the Mechanical Response Tissue Analyzer (MRTA), the UBA-575+, the SoundScan 2000 (S2000), and the Sahara Ultrasound Done Analyzer. Ten men and ten women were scanned on all four devices by two different operators at five discrete time points: Week 1, Week 2, Week 3, Month 3 and Month 6. The percent coefficient of variation (%CV) and standardized coefficient of variation were computed for the following precision characteristics: interoperator effect, operator-subject interaction, short-term error variance, and long-term drift, The MRTA had high interoperator errors for its ulnar and tibial stiffness measures and a large long-term drift in its tibial stiffness measurement. The UBA-575+ exhibited large short-term error variances and long-term drift for all three of its measurements. The S2000's tibial speed of sound measurement showed a high short-term error variance and a significant operator-subject interaction but very good values ( < 1%) for the other precision characteristics. The Sahara seemed to have the best overall performance, but was hampered by a large %CV for short-term error variance in its broadband ultrasound attenuation measure.

  9. Acoustic systems for the measurement of streamflow

    USGS Publications Warehouse

    Laenen, Antonius; Smith, Winchell

    1982-01-01

    Very little information is available concerning acoustic velocity meter (AVM) operation, performance, and limitations. This report provides a better understanding about the application of AVM instrumentation to streamflow measurment. Operational U.S. Geological Survey systems have proven that AVM equipment is accurate and dependable. AVM equipment has no practical upper limit of measureable velocity if sonic transducers are securely placed and adequately protected, and will measure velocitites as low as 0.1 meter per second which is normally less than the threshold level for mechanical or head-loss meters. In some situations the performance of AVM equipment may be degraded by multipath interference, signal bending, signal attenuation, and variable streamline orientation. Smaller, less-expensive, more conveniently operable microprocessor equipment is now available which should increase use of AVM systems in streamflow applications. (USGS)

  10. Validation of streamflow measurements made with acoustic doppler current profilers

    USGS Publications Warehouse

    Oberg, K.; Mueller, D.S.

    2007-01-01

    The U.S. Geological Survey and other international agencies have collaborated to conduct laboratory and field validations of acoustic Doppler current profiler (ADCP) measurements of streamflow. Laboratory validations made in a large towing basin show that the mean differences between tow cart velocity and ADCP bottom-track and water-track velocities were -0.51 and -1.10%, respectively. Field validations of commercially available ADCPs were conducted by comparing streamflow measurements made with ADCPs to reference streamflow measurements obtained from concurrent mechanical current-meter measurements, stable rating curves, salt-dilution measurements, or acoustic velocity meters. Data from 1,032 transects, comprising 100 discharge measurements, were analyzed from 22 sites in the United States, Canada, Sweden, and The Netherlands. Results of these analyses show that broadband ADCP streamflow measurements are unbiased when compared to the reference discharges regardless of the water mode used for making the measurement. Measurement duration is more important than the number of transects for reducing the uncertainty of the ADCP streamflow measurement. ?? 2007 ASCE.

  11. Calibration of ipsilateral stimulus transducer for acoustic reflex measurements.

    PubMed

    Olsen, S; Osterhammel, P A; Rasmussen, A N; Nielsen, L H

    1995-01-01

    Pure-tone Reference Equivalent Threshold Sound Pressure Level (RETSPL) of the ipsilateral stimulus receiver for acoustic reflex measurements on Madsen Electronics type Zodiac 901 impedance audiometer is provided. The results, obtained from 20 normal-hearing subjects, are achieved by comparing hearing threshold levels measured using a TDH 39 telephone (calibrated to ISO 389) with thresholds recorded using the ipsilateral stimulus insert phone. The calibration is referenced to an IEC-711 ear simulator and comprises the following frequencies: 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, 8000 Hz.

  12. Acoustic force measurement in a dual-temperature resonant chamber

    NASA Technical Reports Server (NTRS)

    Robey, Judith L.; Trinh, Eugene H.; Wang, Taylor G.

    1987-01-01

    The acoustic radiation force was measured for a dual-temperature resonant chamber. This rectangular chamber has its long dimension approximately 8.5 times the square cross-sectional dimension, and the opposite ends are at widely different temperatures. Force profiles were obtained for two hot end temperatures of 520 C and 760 C, while the cool end remained at approximately room temperature. Force magnitudes as high as 17 dyn for a sample 1.2 cm in diameter at 760 C and at 162-dB input level were measured.

  13. Acoustic Measurements of Rectangular Nozzles With Bevel

    NASA Technical Reports Server (NTRS)

    Bridges, James E.

    2012-01-01

    A series of convergent rectangular nozzles of aspect ratios 2:1, 4:1, and 8:1 were constructed with uniform exit velocity profiles. Additional nozzles were constructed that extended the wide lip on one side of these nozzles to form beveled nozzles. Far-field acoustic measurements were made and analyzed, and the results presented. The impact of aspect ratio on jet noise was similar to that of enhanced mixing devices: reduction in aft, peak frequency noise with an increase in broadside, high frequency noise. Azimuthally, it was found that rectangular jets produced more noise directed away from their wide sides than from their narrow sides. The azimuthal dependence decreased at aft angles where noise decreased. The effect of temperature, keeping acoustic Mach number constant, was minimal. Since most installations would have the observer on the wide size of the nozzle, the increased high frequency noise has a deleterious impact on the observer. Extending one wide side of the rectangular nozzle, evocative of an aft deck in an installed propulsion system, increased the noise of the jet with increasing length. The impact of both aspect ratio and bevel length were relatively well behaved, allowing a simple bilinear model to be constructed relative to a simple round jet.

  14. Acoustic Measurements of Rectangular Nozzles with Bevel

    NASA Technical Reports Server (NTRS)

    Bridges, James E.

    2012-01-01

    A series of convergent rectangular nozzles of aspect ratios 2:1, 4:1, and 8:1 were constructed with uniform exit velocity profiles. Additional nozzles were constructed that extended the wide lip on one side of these nozzles to form beveled nozzles. Far-field acoustic measurements were made and analyzed, and the results presented. The impact of aspect ratio on jet noise was similar to that of enhanced mixing devices: reduction in aft, peak frequency noise with an increase in broadside, high frequency noise. Azimuthally, it was found that rectangular jets produced more noise directed away from their wide sides than from their narrow sides. The azimuthal dependence decreased at aft angles where noise decreased. The effect of temperature, keeping acoustic Mach number constant, was minimal. Since most installations would have the observer on the wide size of the nozzle, the increased high frequency noise has a deleterious impact on the observer. Extending one wide side of the rectangular nozzle, evocative of an aft deck in an installed propulsion system, increased the noise of the jet with increasing length. The impact of both aspect ratio and bevel length were relatively well behaved, allowing a simple bilinear model to be constructed relative to a simple round jet.

  15. Resin characterization by electro-acoustic measurements.

    PubMed

    Müller, Egbert; Mann, Christian

    2007-03-09

    The electro-acoustic effects, namely the ion vibration potential (IVP) and the colloidal vibration current (CVI), colloidal vibration potential (CVP) first described by P. Debye [P. Debye, J. Chem. Phys. 1 (1933) 13], are a result of charge separation of bound or free ions at different degrees by ultrasonic waves. Today commercial instruments are available to investigate liquid homogeneous and heterogeneous systems. In the present paper the application of this technique for the characterization of salts, protein solutions and resins for biochromatography is shown and valuable information about resins can be derived in a short time. Various resins were investigated with the following results: (1) the CVI magnitude is dependent of several parameters (such as particle size distribution, volume fraction, density difference); (2) the CVI is influenced by the surface modification of the resins. Polymeric modifications decrease the value of CVI. The CVI is generally lower for high capacity resins; (3) the measurement of the electro-acoustic effects can be used to detect small changes in resins. The CVI is dependent of the amount of adsorbed protein in "native" and denatured state.

  16. Ares I Scale Model Acoustic Tests Instrumentation for Acoustic and Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Vargas, Magda B.; Counter, Douglas D.

    2011-01-01

    The Ares I Scale Model Acoustic Test (ASMAT) was a development test performed at the Marshall Space Flight Center (MSFC) East Test Area (ETA) Test Stand 116. The test article included a 5% scale Ares I vehicle model and tower mounted on the Mobile Launcher. Acoustic and pressure data were measured by approximately 200 instruments located throughout the test article. There were four primary ASMAT instrument suites: ignition overpressure (IOP), lift-off acoustics (LOA), ground acoustics (GA), and spatial correlation (SC). Each instrumentation suite incorporated different sensor models which were selected based upon measurement requirements. These requirements included the type of measurement, exposure to the environment, instrumentation check-outs and data acquisition. The sensors were attached to the test article using different mounts and brackets dependent upon the location of the sensor. This presentation addresses the observed effect of the sensors and mounts on the acoustic and pressure measurements.

  17. Extreme low frequency acoustic measurement system

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2013-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  18. Extreme Low Frequency Acoustic Measurement System

    NASA Technical Reports Server (NTRS)

    Shams, Qamar A. (Inventor); Zuckerwar, Allan J. (Inventor)

    2017-01-01

    The present invention is an extremely low frequency (ELF) microphone and acoustic measurement system capable of infrasound detection in a portable and easily deployable form factor. In one embodiment of the invention, an extremely low frequency electret microphone comprises a membrane, a backplate, and a backchamber. The backchamber is sealed to allow substantially no air exchange between the backchamber and outside the microphone. Compliance of the membrane may be less than ambient air compliance. The backplate may define a plurality of holes and a slot may be defined between an outer diameter of the backplate and an inner wall of the microphone. The locations and sizes of the holes, the size of the slot, and the volume of the backchamber may be selected such that membrane motion is substantially critically damped.

  19. Outdoor Synthetic Aperture Acoustic Ground Target Measurements

    DTIC Science & Technology

    2010-04-19

    1341 (2003). [11] C. A. Dimarzio, T. Shi, F. J. Blonigen et al., “ Laser -Induced Acoustic Landmine Detection,” The Journal Of The Acoustical Society...High Frequency A/S Coupling For Ap Buried Landmine Detection Using Laser Doppler Vibrometers,” Proc. SPIE 5415(1), 35-41 (2004). [16] Bishop, S... Dolphin Echolocation Clicks For Target Discrimination,” The Journal Of The Acoustical Society Of America 124(1), 657-666 (2008). [20] Y. Nakamura

  20. Acoustic systems for the measurement of streamflow

    USGS Publications Warehouse

    Laenen, Antonius; Smith, Winchell

    1983-01-01

    The acoustic velocity meter (AVM), also referred to as an ultrasonic flowmeter, has been an operational tool for the measurement of streamflow since 1965. Very little information is available concerning AVM operation, performance, and limitations. The purpose of this report is to consolidate information in such a manner as to provide a better understanding about the application of this instrumentation to streamflow measurement. AVM instrumentation is highly accurate and nonmechanical. Most commercial AVM systems that measure streamflow use the time-of-travel method to determine a velocity between two points. The systems operate on the principle that point-to-point upstream travel-time of sound is longer than the downstream travel-time, and this difference can be monitored and measured accurately by electronics. AVM equipment has no practical upper limit of measurable velocity if sonic transducers are securely placed and adequately protected. AVM systems used in streamflow measurement generally operate with a resolution of ?0.01 meter per second but this is dependent on system frequency, path length, and signal attenuation. In some applications the performance of AVM equipment may be degraded by multipath interference, signal bending, signal attenuation, and variable streamline orientation. Presently used minicomputer systems, although expensive to purchase and maintain, perform well. Increased use of AVM systems probably will be realized as smaller, less expensive, and more conveniently operable microprocessor-based systems become readily available. Available AVM equipment should be capable of flow measurement in a wide variety of situations heretofore untried. New signal-detection techniques and communication linkages can provide additional flexibility to the systems so that operation is possible in more river and estuary situations.

  1. Method and means for measuring acoustic emissions

    DOEpatents

    Renken, Jr., Claus J.

    1976-01-06

    The detection of acoustic emissions emanating from an object is achieved with a capacitive transducer coupled to the object. The capacitive transducer is charged and then allowed to discharge with the rate of discharge being monitored. Oscillations in the rate of discharge about the normally exponential discharge curve for the capacitive transducer indicate the presence of acoustic emissions.

  2. Field Measurement of the Acoustic Nonlinearity Parameter in Turbine Blades

    NASA Technical Reports Server (NTRS)

    Hinton, Yolanda L.; Na, Jeong K.; Yost, William T.; Kessel, Gregory L.

    2000-01-01

    Nonlinear acoustics techniques were used to measure fatigue in turbine blades in a power generation plant. The measurements were made in the field using a reference based measurement technique, and a reference sample previously measured in the laboratory. The acoustic nonlinearity parameter showed significant increase with fatigue in the blades, as indicated by service age and areas of increased stress. The technique shows promise for effectively measuring fatigue in field applications and predicting subsequent failures.

  3. Prediction and Measurement of the Vibration and Acoustic Radiation of Panels Subjected to Acoustic Loading

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.; Rizzi, Stephen A.

    1995-01-01

    Interior noise and sonic fatigue are important issues in the development and design of advanced subsonic and supersonic aircraft. Conventional aircraft typically employ passive treatments, such as constrained layer damping and acoustic absorption materials, to reduce the structural response and resulting acoustic levels in the aircraft interior. These techniques require significant addition of mass and only attenuate relatively high frequency noise transmitted through the fuselage. Although structural acoustic coupling is in general very important in the study of aircraft fuselage interior noise, analysis of noise transmission through a panel supported in an infinite rigid baffle (separating two semi-infinite acoustic domains) can be useful in evaluating the effects of active/adaptive materials, complex loading, etc. Recent work has been aimed at developing adaptive and/or active methods of controlling the structural acoustic response of panels to reduce the transmitted noise1. A finite element formulation was recently developed to study the dynamic response of shape memory alloy (SMA) hybrid composite panels (conventional composite panel with embedded SMA fibers) subject to combined acoustic and thermal loads2. Further analysis has been performed to predict the far-field acoustic radiation using the finite element dynamic panel response prediction3. The purpose of the present work is to validate the panel vibration and acoustic radiation prediction methods with baseline experimental results obtained from an isotropic panel, without the effect of SMA.

  4. Photo-acoustic tomography in a rotating measurement setting

    NASA Astrophysics Data System (ADS)

    Bal, Guillaume; Moradifam, Amir

    2016-10-01

    Photo-acoustic tomography (PAT) aims to leverage the photo-acoustic coupling between optical absorption of light sources and ultrasound (US) emission to obtain high contrast reconstructions of optical parameters with the high resolution of sonic waves. Quantitative PAT often involves a two-step procedure: first the map of sonic emission is reconstructed from US boundary measurements; and second optical properties of biological tissues are evaluated. We consider here a practical measurement setting in which such a separation does not apply. We assume that the optical source and an array of ultrasonic transducers are mounted on a rotating frame (in two or three dimensions) so that the light source rotates at the same time as the US measurements are acquired. As a consequence, we no longer have the option to reconstruct a map of sonic emission corresponding to a given optical illumination. We propose here a framework where the two steps are combined into one and an absorption map is directly reconstructed from the available US measurements.

  5. Compensating for ear-canal acoustics when measuring otoacoustic emissions.

    PubMed

    Charaziak, Karolina K; Shera, Christopher A

    2017-01-01

    Otoacoustic emissions (OAEs) provide an acoustic fingerprint of the inner ear, and changes in this fingerprint may indicate changes in cochlear function arising from efferent modulation, aging, noise trauma, and/or exposure to harmful agents. However, the reproducibility and diagnostic power of OAE measurements is compromised by the variable acoustics of the ear canal, in particular, by multiple reflections and the emergence of standing waves at relevant frequencies. Even when stimulus levels are controlled using methods that circumvent standing-wave problems (e.g., forward-pressure-level calibration), distortion-product otoacoustic emission (DPOAE) levels vary with probe location by 10-15 dB near half-wave resonant frequencies. The method presented here estimates the initial outgoing OAE pressure wave at the eardrum from measurements of the conventional OAE, allowing one to separate the emitted OAE from the many reflections trapped in the ear canal. The emitted pressure level (EPL) represents the OAE level that would be recorded were the ear canal replaced by an infinite tube with no reflections. When DPOAEs are expressed using EPL, their variation with probe location decreases to the test-retest repeatability of measurements obtained at similar probe positions. EPL provides a powerful way to reduce the variability of OAE measurements and improve their ability to detect cochlear changes.

  6. Applications of acoustics in the measurement of coal slab thickness

    NASA Technical Reports Server (NTRS)

    Hadden, W. J., Jr.; Mills, J. M.; Pierce, A. D.

    1980-01-01

    The determination of the possibility of employing acoustic waves at ultrasonic frequencies for measurements of thicknesses of slabs of coal backed by shale is investigated. Fundamental information concerning the acoustical properties of coal, and the relationship between these properties and the structural and compositional parameters used to characterize coal samples was also sought. The testing device, which utilizes two matched transducers, is described.

  7. Ares I Scale Model Acoustic Test Instrumentation for Acoustic and Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Vargas, Magda B.; Counter, Douglas

    2011-01-01

    Ares I Scale Model Acoustic Test (ASMAT) is a 5% scale model test of the Ares I vehicle, launch pad and support structures conducted at MSFC to verify acoustic and ignition environments and evaluate water suppression systems Test design considerations 5% measurements must be scaled to full scale requiring high frequency measurements Users had different frequencies of interest Acoustics: 200 - 2,000 Hz full scale equals 4,000 - 40,000 Hz model scale Ignition Transient: 0 - 100 Hz full scale equals 0 - 2,000 Hz model scale Environment exposure Weather exposure: heat, humidity, thunderstorms, rain, cold and snow Test environments: Plume impingement heat and pressure, and water deluge impingement Several types of sensors were used to measure the environments Different instrument mounts were used according to the location and exposure to the environment This presentation addresses the observed effects of the selected sensors and mount design on the acoustic and pressure measurements

  8. Cosmological implications of baryon acoustic oscillation measurements

    SciTech Connect

    Aubourg, Eric

    2015-12-01

    Here, we derive constraints on cosmological parameters and tests of dark energy models from the combination of baryon acoustic oscillation (BAO) measurements with cosmic microwave background (CMB) data and a recent reanalysis of Type Ia supernova (SN) data. Particularly, we take advantage of high-precision BAO measurements from galaxy clustering and the Lyman-α forest (LyaF) in the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). Treating the BAO scale as an uncalibrated standard ruler, BAO data alone yield a high confidence detection of dark energy; in combination with the CMB angular acoustic scale they further imply a nearly flat universe. Adding the CMB-calibrated physical scale of the sound horizon, the combination of BAO and SN data into an “inverse distance ladder” yields a measurement of H0=67.3±1.1 km s-1 Mpc-1, with 1.7% precision. This measurement assumes standard prerecombination physics but is insensitive to assumptions about dark energy or space curvature, so agreement with CMB-based estimates that assume a flat ΛCDM cosmology is an important corroboration of this minimal cosmological model. For constant dark energy (Λ), our BAO+SN+CMB combination yields matter density Ωm=0.301±0.008 and curvature Ωk=-0.003±0.003. When we allow more general forms of evolving dark energy, the BAO+SN+CMB parameter constraints are always consistent with flat ΛCDM values at ≈1σ. And while the overall χ2 of model fits is satisfactory, the LyaF BAO measurements are in moderate (2–2.5σ) tension with model predictions. Models with early dark energy that tracks the dominant energy component at high redshift remain consistent with our expansion history constraints, and they yield a higher H0 and lower matter clustering amplitude, improving agreement with some low redshift observations. Expansion history alone yields an upper limit on the summed mass of neutrino species,

  9. Cosmological implications of baryon acoustic oscillation measurements

    DOE PAGES

    Aubourg, Eric

    2015-12-01

    Here, we derive constraints on cosmological parameters and tests of dark energy models from the combination of baryon acoustic oscillation (BAO) measurements with cosmic microwave background (CMB) data and a recent reanalysis of Type Ia supernova (SN) data. Particularly, we take advantage of high-precision BAO measurements from galaxy clustering and the Lyman-α forest (LyaF) in the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). Treating the BAO scale as an uncalibrated standard ruler, BAO data alone yield a high confidence detection of dark energy; in combination with the CMB angular acoustic scale they further imply a nearly flat universe. Adding the CMB-calibratedmore » physical scale of the sound horizon, the combination of BAO and SN data into an “inverse distance ladder” yields a measurement of H0=67.3±1.1 km s-1 Mpc-1, with 1.7% precision. This measurement assumes standard prerecombination physics but is insensitive to assumptions about dark energy or space curvature, so agreement with CMB-based estimates that assume a flat ΛCDM cosmology is an important corroboration of this minimal cosmological model. For constant dark energy (Λ), our BAO+SN+CMB combination yields matter density Ωm=0.301±0.008 and curvature Ωk=-0.003±0.003. When we allow more general forms of evolving dark energy, the BAO+SN+CMB parameter constraints are always consistent with flat ΛCDM values at ≈1σ. And while the overall χ2 of model fits is satisfactory, the LyaF BAO measurements are in moderate (2–2.5σ) tension with model predictions. Models with early dark energy that tracks the dominant energy component at high redshift remain consistent with our expansion history constraints, and they yield a higher H0 and lower matter clustering amplitude, improving agreement with some low redshift observations. Expansion history alone yields an upper limit on the summed mass of neutrino species, Σmν<0.56 eV (95% confidence), improving to Σmν<0.25 eV if we include

  10. Acoustic-velocity measurements in materials using a regenerative method

    DOEpatents

    Laine, E.F.

    1982-09-30

    Acoustic energy is propatated through earth material between an electro-acoustic generator and a receiver which converts the received acoustic energy into electrical signals. A closed loop is formed by a variable gain amplifier system connected between the receiver and the generator. The gain of the amplifier system is increased until sustained oscillations are produced in the closed loop. The frequency of the oscillations is measured as an indication of the acoustic propagation velocity through the earth material. The amplifier gain is measured as an indication of the acoustic attenuation through the earth materials. The method is also applicable to the non-destructive testing of structural materials, such as steel, aluminum and concrete.

  11. Acoustic velocity measurements in materials using a regenerative method

    DOEpatents

    Laine, Edwin F.

    1986-01-01

    Acoustic energy is propagated through earth material between an electro-acoustic generator and a receiver which converts the received acoustic energy into electrical signals. A closed loop is formed by a variable gain amplifier system connected between the receiver and the generator. The gain of the amplifier system is increased until sustained oscillations are produced in the closed loop. The frequency of the oscillations is measured as an indication of the acoustic propagation velocity through the earth material. The amplifier gain is measured as an indication of the acoustic attenuation through the earth materials. The method is also applicable to the non-destructive testing of structural materials, such as steel, aluminum and concrete.

  12. Measurements of the force fields within an acoustic standing wave using holographic optical tweezers

    SciTech Connect

    Bassindale, P. G.; Drinkwater, B. W.; Phillips, D. B.; Barnes, A. C.

    2014-04-21

    Direct measurement of the forces experienced by micro-spheres in an acoustic standing wave device have been obtained using calibrated optical traps generated with holographic optical tweezers. A micro-sphere, which is optically trapped in three dimensions, can be moved through the acoustic device to measure forces acting upon it. When the micro-sphere is subjected to acoustic forces, it's equilibrium position is displaced to a position where the acoustic forces and optical forces are balanced. Once the optical trapping stiffness has been calibrated, observation of this displacement enables a direct measurement of the forces acting upon the micro-sphere. The measured forces are separated into a spatially oscillating component, attributed to the acoustic radiation force, and a constant force, attributed to fluid streaming. As the drive conditions of the acoustic device were varied, oscillating forces (>2.5 pN{sub pp}) and streaming forces (<0.2 pN) were measured. A 5 μm silica micro-sphere was used to characterise a 6.8 MHz standing wave, λ = 220 μm, to a spatial resolution limited by the uncertainty in the positioning of the micro-sphere (here to within 2 nm) and with a force resolution on the order of 10 fN. The results have application in the design and testing of acoustic manipulation devices.

  13. Scale Model Thruster Acoustic Measurement Results

    NASA Technical Reports Server (NTRS)

    Vargas, Magda; Kenny, R. Jeremy

    2013-01-01

    The Space Launch System (SLS) Scale Model Acoustic Test (SMAT) is a 5% scale representation of the SLS vehicle, mobile launcher, tower, and launch pad trench. The SLS launch propulsion system will be comprised of the Rocket Assisted Take-Off (RATO) motors representing the solid boosters and 4 Gas Hydrogen (GH2) thrusters representing the core engines. The GH2 thrusters were tested in a horizontal configuration in order to characterize their performance. In Phase 1, a single thruster was fired to determine the engine performance parameters necessary for scaling a single engine. A cluster configuration, consisting of the 4 thrusters, was tested in Phase 2 to integrate the system and determine their combined performance. Acoustic and overpressure data was collected during both test phases in order to characterize the system's acoustic performance. The results from the single thruster and 4- thuster system are discussed and compared.

  14. Acoustic measurement of the surface tension of levitated drops

    NASA Technical Reports Server (NTRS)

    Trinh, E. H.; Marston, P. L.; Robey, J. L.

    1988-01-01

    The measurement of the frequency of the fundamental mode of shape oscillation of acoustically levitated drops has been carried out to determine the surface tension of the drop material. Sound fields of about 20 kHz in frequency allow the suspension of drops a few millimeters in size, as well as the necessary drive for oscillations. The surface tension of water, hexadecane, silicone oil, and aqueous solutions of glycerin levitated in air has been measured, and the results have been compared with those obtained with standard ring tensiometry. The two sets of data are in good agreement, the largest discrepancy being about 10 percent. Uncertainties in the effects of the nonspherical static shape of drops levitated in the earth's gravitational field and the rotation state of the sample are the major contributors to the experimental error. A decrease of the resonance frequency of the fundamental mode indicates a soft nonlinearity as the oscillation amplitude increases.

  15. Measurement of a broadband negative index with space-coiling acoustic metamaterials.

    PubMed

    Xie, Yangbo; Popa, Bogdan-Ioan; Zigoneanu, Lucian; Cummer, Steven A

    2013-04-26

    We report the experimental demonstration of a broadband negative refractive index obtained in a labyrinthine acoustic metamaterial structure. Two different approaches were employed to prove the metamaterial negative index nature: one-dimensional extractions of effective parameters from reflection and transmission measurements and two-dimensional prism-based measurements that convincingly show the transmission angle corresponding to negative refraction. The transmission angles observed in the latter case also agree very well with the refractive index obtained in the one-dimensional measurements and numerical simulations. We expect this labyrinthine metamaterial to become the unit cell of choice for practical acoustic metamaterial devices that require broadband and significantly negative indices of refraction.

  16. A fast full frequency range measurement of nonlinear distortions in the vibration of acoustic transducers and acoustically driven membranes

    NASA Astrophysics Data System (ADS)

    Aerts, J. R. M.; Dirckx, J. J. J.

    2007-11-01

    Recently, a new method was proposed to measure nonlinear distortions in weak nonlinear systems using specially designed broadband excitation signals (odd random phase multisines). During one single experiment, the output response level, the noise level and the level of the nonlinear distortions are simultaneously measured. We implement this method in an opto-acoustic set-up which allows us to measure vibrations with high accuracy. To demonstrate the method, we present results obtained on the membrane of an earphone speaker and a latex membrane. On the earphone good agreement is found between measurements of the produced sound field and the actual membrane vibration using heterodyne interferometry. The results show that heterodyne vibrometry can be used to detect nonlinear distortions which are up to 80 dB below the output level in an acoustically driven system.

  17. Structure influence on mechanical and acoustic properties of freeze-dried gels obtained with the use of hydrocolloids.

    PubMed

    Ciurzyńska, Agnieszka; Marzec, Agata; Mieszkowska, Arleta; Lenart, Andrzej

    2017-04-01

    The influence of the structure formed by the type of hydrocolloids (low-methoxyl pectin, the mixture of xanthan gum, and locust bean gum, and mixture of xanthan gum, and guar gum) and the aeration time (3, 5, 7, and 9 min) on textural properties of freeze-dried gels were investigated. The hardest texture generating the strongest acoustic emission was obtained by freeze-dried pectin gel, characterised by the lowest porosity and the largest pore diameter. Aeration time significantly affected mechanical and acoustic properties of the pectin gel lyophilisate. No effect of gel aeration time on tested characteristics of samples with mixture of hydrocolloids was observed. Strong positive correlations between acoustic energy as well as the maximum force and work and negative ones between porosity and pore diameter indicate that greater resilience and stronger acoustic emission of freeze-dried gels was caused by the reduction of porosity and the increase in the pore size of the material.

  18. Acoustic wayfinding: A method to measure the acoustic contrast of different paving materials for blind people.

    PubMed

    Secchi, Simone; Lauria, Antonio; Cellai, Gianfranco

    2017-01-01

    Acoustic wayfinding involves using a variety of auditory cues to create a mental map of the surrounding environment. For blind people, these auditory cues become the primary substitute for visual information in order to understand the features of the spatial context and orient themselves. This can include creating sound waves, such as tapping a cane. This paper reports the results of a research about the "acoustic contrast" parameter between paving materials functioning as a cue and the surrounding or adjacent surface functioning as a background. A number of different materials was selected in order to create a test path and a procedure was defined for the verification of the ability of blind people to distinguish different acoustic contrasts. A method is proposed for measuring acoustic contrast generated by the impact of a cane tip on the ground to provide blind people with environmental information on spatial orientation and wayfinding in urban places.

  19. Acoustic temperature measurement in a rocket noise field.

    PubMed

    Giraud, Jarom H; Gee, Kent L; Ellsworth, John E

    2010-05-01

    A 1 μm diameter platinum wire resistance thermometer has been used to measure temperature fluctuations generated during a static GEM-60 rocket motor test. Exact and small-signal relationships between acoustic pressure and acoustic temperature are derived in order to compare the temperature probe output with that of a 3.18 mm diameter condenser microphone. After preliminary plane wave tests yielded good agreement between the transducers within the temperature probe's ∼2 kHz bandwidth, comparison between the temperature probe and microphone data during the motor firing show that the ±∼3 K acoustic temperature fluctuations are a significant contributor to the total temperature variations.

  20. Acoustic measurements of a full-scale coaxial helicopter

    NASA Technical Reports Server (NTRS)

    Mosher, M.; Peterson, R. L.

    1983-01-01

    Acoustic data were obtained during a full-scale test of the XH-59A Advancing Blade Concept (ABC) Technology Demonstrator in the NASA Ames 40- by 80-Foot Wind Tunnel. The XH-59A is a research helicopter with two coaxial rotors and hingeless blades. Performance, vibration, noise at various forward speeds, rotor lift coefficients, and rotor shaft angles of attack were investigated. In general, the noise level is shown to increase with rotor lift coefficient except under certain operating conditions where it is increased by significant impulsive blade/vortex interactions. The impulsivity appears to depend upon how the lift is distributed between the two rotors. The noise levels measured are shown to be slightly higher than on a modern conventional rotor tested in the same facility.

  1. Picosecond Acoustic Measurement of Anisotropic Properties of Thin Films

    SciTech Connect

    Perton, M.; Rossignol, C.; Chigarev, N.; Audoin, B.

    2007-03-21

    Properties of thin metallic films have been studied extensively by means of laser-picosecond ultrasonics. Generation of longitudinal and shear waves via thermoelastic mechanism and large source has been only demonstrated for waves vectors along the normal to the interface. However, such measurements cannot provide complete information about elastic properties of films. As it has been already shown for nanosecond ultrasonics, the knowledge of group or phase velocities in several directions for sources with small lateral size allows determining the stiffness tensor coefficients of a sample. The experimental set-up was prepared to obtain the thinnest size for the source to achieve acoustic diffraction. The identification of the stiffness tensor components, based on the inversion of the bulk waves phase velocities, is applied to signals simulated and experimentally recorded for a material with hexagonal properties. First estimation of stiffness tensor coefficients for thin metallic film 2.1 {mu}m has been performed.

  2. Classroom acoustics in Omaha, Nebraska: Measurements and outreach

    NASA Astrophysics Data System (ADS)

    Bowden, Erica E.; Wang, Lily M.; Bradley, David T.

    2002-11-01

    This project collected data detailing the current status of classroom acoustics while simultaneously increasing awareness of educational acoustics and exposure to acoustical engineering research in local schools. In 8 Omaha-area schools, 2 acoustical aspects which directly influence speech intelligibility were measured and studied: (1) background noise levels resulting from a building's mechanical systems; and (2) reverberation times within the classroom. Prior to each measurement session, a presentation on good classroom acoustic principles was presented to the teacher and students in that classroom. Subsequently, the teacher and students assisted the principal investigator and research assistants in the measurement of the acoustic data from their classroom. In total, 13 classrooms were studied, with the assistance of 425 middle and high school students in 14 different classes. The background noise results have been associated with commonly used noise criterion curves. Results are compared to recommended background noise levels and reverberation times suggested by ANSI standard S12.60-2002. The resulting database provides knowledge on the current status of classrooms in Omaha, and may be indicative of classroom situations across the midwestern United States.

  3. Obtaining Acoustic Cue Rate Estimates for Some Mysticete Species Using Existing Data

    DTIC Science & Technology

    2015-09-30

    Mysticete Species using Existing Data Tyler A. Helble Marine Mammals and Autonomous Underwater Vehicles, Code 56440 Space and Naval Warfare Systems...acoustics is the estimation of animal population densities from detections in passive acoustic data . In order to calculate animal density from passive...physalus), also can be estimated from existing data sets (e.g., the MNT/FET data set collected in 1999 by the ADS program) and so warrants additional

  4. Relation between near field and far field acoustic measurements

    NASA Technical Reports Server (NTRS)

    Bies, D. A.; Scharton, T. D.

    1974-01-01

    Several approaches to the problem of determining the far field directivity of an acoustic source located in a reverberant environment, such as a wind tunnel, are investigated analytically and experimentally. The decrease of sound pressure level with distance is illustrated; and the spatial extent of the hydrodynamic and geometric near fields, the far field, and the reverberant field are described. A previously-prosposed analytical technique for predicting the far field directivity of the acoustic source on the basis of near field data is investigated. Experiments are conducted with small acoustic sources and an analysis is performed to determine the variation with distance from the source of the directionality of the sound field. A novel experiment is conducted in which the sound pressure measured at various distances from an acoustic driver located in the NASA Ames 40 x 80 ft wind tunnel is crosscorrelated with the driver excitation voltage.

  5. Acoustic Measurements of a Large Civil Transport Main Landing Gear Model

    NASA Technical Reports Server (NTRS)

    Ravetta, Patricio A.; Khorrami, Mehdi R.; Burdisso, Ricardo A.; Wisda, David M.

    2016-01-01

    Microphone phased array acoustic measurements of a 26 percent-scale, Boeing 777-200 main landing gear model with and without noise reduction fairings installed were obtained in the anechoic configuration of the Virginia Tech Stability Tunnel. Data were acquired at Mach numbers of 0.12, 0.15, and 0.17 with the latter speed used as the nominal test condition. The fully and partially dressed gear with the truck angle set at 13 degrees toe-up landing configuration were the two most extensively tested configurations, serving as the baselines for comparison purposes. Acoustic measurements were also acquired for the same two baseline configurations with the truck angle set at 0 degrees. In addition, a previously tested noise reducing, toboggan-shaped fairing was re-evaluated extensively to address some of the lingering questions regarding the extent of acoustic benefit achievable with this device. The integrated spectra generated from the acoustic source maps reconfirm, in general terms, the previously reported noise reduction performance of the toboggan fairing as installed on an isolated gear. With the recent improvements to the Virginia Tech tunnel acoustic quality and microphone array capabilities, the present measurements provide an additional, higher quality database to the acoustic information available for this gear model.

  6. On acoustic intensity measurements in the presence of mean flow

    NASA Technical Reports Server (NTRS)

    Munro, D. H.; Ingard, K. U.

    1979-01-01

    A theoretical analysis demonstrates that the technique of measuring acoustic intensity by means of cross correlation between nearby microphones cannot, in general, be extended to situations in which there is mean flow. However, it may be possible to use this technique to measure intensities in ducts with mean flow at frequencies below their cutoff frequencies.

  7. Acoustic measurement study 40 by 80 foot subsonic wind tunnel

    NASA Technical Reports Server (NTRS)

    1974-01-01

    An acoustical study conducted during the period from September 1, 1973 to April 30, 1974 measured sound pressure levels and vibration amplitudes inside and outside of the subsonic tunnel and on the tunnel structure. A discussion of the technical aspects of the study, the field measurement and data reduction procedures, and results are presentd, and conclusions resulting from the study which bear upon near field and far field tunnel noise, upon the tunnel as an acoustical enclosure, and upon the sources of noise within the tunnel drive system are given.

  8. An optoacoustic point source for acoustic scale model measurements.

    PubMed

    Bolaños, Javier Gómez; Pulkki, Ville; Karppinen, Pasi; Hæggström, Edward

    2013-04-01

    A massless acoustic source is proposed for scale model work. This source is generated by focusing a pulsed laser beam to rapidly heat the air at the focal point. This produces an expanding small plasma ball which generates a sonic impulse that may be used as an acoustic point source. Repeatability, frequency response, and directivity of the source were measured to show that it can serve as a massless point source. The impulse response of a rectangular space was determined using this type of source. A good match was found between the predicted and the measured impulse responses of the space.

  9. Comparison of cosmology and seabed acoustics measurements using statistical inference from maximum entropy

    NASA Astrophysics Data System (ADS)

    Knobles, David; Stotts, Steven; Sagers, Jason

    2012-03-01

    Why can one obtain from similar measurements a greater amount of information about cosmological parameters than seabed parameters in ocean waveguides? The cosmological measurements are in the form of a power spectrum constructed from spatial correlations of temperature fluctuations within the microwave background radiation. The seabed acoustic measurements are in the form of spatial correlations along the length of a spatial aperture. This study explores the above question from the perspective of posterior probability distributions obtained from maximizing a relative entropy functional. An answer is in part that the seabed in shallow ocean environments generally has large temporal and spatial inhomogeneities, whereas the early universe was a nearly homogeneous cosmological soup with small but important fluctuations. Acoustic propagation models used in shallow water acoustics generally do not capture spatial and temporal variability sufficiently well, which leads to model error dominating the statistical inference problem. This is not the case in cosmology. Further, the physics of the acoustic modes in cosmology is that of a standing wave with simple initial conditions, whereas for underwater acoustics it is a traveling wave in a strongly inhomogeneous bounded medium.

  10. Acoustic Liner Drag: Measurements on Novel Facesheet Perforate Geometries

    NASA Technical Reports Server (NTRS)

    Howerton, Brian M.; Jones, Michael G.

    2016-01-01

    Interest in characterization of the aerodynamic drag of acoustic liners has increased in the past several years. This paper details experiments in the NASA Langley Grazing Flow Impedance Tube to quantify the relative drag of several perforate-over-honeycomb liner configurations at flow speeds of centerline flow Mach number equals 0.3 and 0.5. Various perforate geometries and orientations are investigated to determine their resistance factors using a static pressure drop approach. Comparison of these resistance factors gives a relative measurement of liner drag. For these same flow conditions, acoustic measurements are performed with tonal excitation from 400 to 3000 hertz at source sound pressure levels of 140 and 150 decibels. Educed impedance and attenuation spectra are used to determine the impact of variations in perforate geometry on acoustic performance.

  11. End tidal carbon dioxide measurement using an electro acoustic sensor.

    PubMed

    Folke, M; Hok, B; Ekstrom, M; Backlund, Y

    2004-01-01

    End tidal carbon dioxide measurement with an electro-acoustic sensor is demonstrated. The sensor consists of an acoustic resonator coupled to a low cost electro-acoustic element. By simultaneous measurements with a reference sensor, the new device was tested on subjects performing exercise, hypo- and hyperventilation whereby the CO2concentration ranged from 2.1 to 7.0 kPa. The output from the experimental device correlated well with the reference CO2readings with a correlation coefficient of 0.976. Response time for expiration less than 0.8 seconds was noted. The new device could be useful in situations where selectivity to other gases is not important.

  12. Near field acoustic holography measurements of carbon nanotube thin film speakers.

    PubMed

    Asgarisabet, Mahsa; Barnard, Andrew R; Bouman, Troy M

    2016-12-01

    Carbon nanotube (CNT) thin film speakers produce sound with the thermoacoustic effect. Better understanding of the physical acoustic properties of these speakers will drive future design improvements. Measuring acoustic properties at the surface of the CNT thin film is difficult because the films, themselves, do not vibrate, are fragile and have a high surface temperature. In order to measure the surface particle velocity and sound pressure level (SPL), near field acoustic holography (NAH) has been used by employing probe microphones. NAH images the acoustic quantities of the source system using the set of acoustic pressure measurements on a hologram parallel to the source surface. It is shown that the particle velocity at the surface of an open-air, double-sided speaker is nominally zero, as expected. However, the SPL distribution is not uniform on the source surface, contrary to common lumped parameter model assumptions. Also, particle velocity and sound intensity distributions on the hologram have been obtained in this study. Finally, measured directivity patterns of the planar CNT speaker are reported.

  13. Identification of vibration excitations from acoustic measurements using near field acoustic holography and the force analysis technique

    NASA Astrophysics Data System (ADS)

    Pézerat, C.; Leclère, Q.; Totaro, N.; Pachebat, M.

    2009-10-01

    This study presents a method of using acoustic holography and the force analysis technique to identify vibration sources from radiated noise measurements. The structure studied is a plate excited by a shaker on which three measurements were performed: the first is a reference measurement of plate velocity obtained by scanning laser vibrometry, the second is based on sound pressure measurements in the near field of the structure, and the third is the measurement of normal acoustic velocities by using a p-U probe recently developed by Microflown Technologies. This was followed by the application of classical NAH, known as pressure-to-velocity holography and velocity-to-velocity holography to predict the plate velocity field from acoustic measurements at distances of 1 and 5 cm. Afterwards, the force analysis technique, also known as the RIFF technique, is applied with these five data sets. The principle is to inject the displacement field of the structure into its equation of motion and extract the resulting force distribution. This technique requires regularization done by a low-pass filter in the wavenumber domain. Apart from pressure-to-velocity holography at 5 cm, the reconstructed force distribution allows localizing the excitation point in the measurement area. FAT regularization is also shown to improve results as its cutoff wavenumber is optimized with the natural wavenumber of the plate. Lastly, quantitative force values are extracted from force distributions at all frequencies of the band 0-4 kHz studied and compared with the force spectrum measured directly by a piezoelectric sensor.

  14. A new method to measure the acoustic surface impedance outdoors.

    PubMed

    Carpinello, S; L'Hermite, Ph; Bérengier, M; Licitra, G

    2004-01-01

    In the European countries noise pollution is considered to be one of the most important environmental problems. With respect to traffic noise, different researchers are working on the reduction of noise at the source, on the modelling of the acoustic absorption of the road structure and on the effects of the pavement on the propagation. The aim of this paper is to propose a new method to measure the acoustic impedance of surfaces located outdoors, which allows us to further noise propagation models, in order to evaluate exactly the noise exposure.

  15. Advances in non-invasive measures of vocal acoustics.

    PubMed

    LaBlance, G R; Steckol, K F; Cooper, M H

    1991-10-01

    Objective assessment of vocal pitch, loudness, and quality is a crucial adjunct to endoscopy in the diagnosis and treatment of vocal pathology. Historically, this assessment was made through subjective, perceptual measures that were questionable in terms of validity and reliability. Recent advances in electronic technology now permit objective analysis of the acoustic characteristics of voice. Kay Elemetric's Visi-Pitch, DSP 5500 Digital Spectrograph, and Nasometer are representative of these new instruments and are used as illustrations in the discussion of the assessment of speech acoustics.

  16. Acoustic ship signature measurements by cross-correlation method.

    PubMed

    Fillinger, Laurent; Sutin, Alexander; Sedunov, Alexander

    2011-02-01

    Cross-correlation methods were applied for the estimation of the power spectral density and modulation spectrum of underwater noise generated by moving vessels. The cross-correlation of the signal from two hydrophones allows the separation of vessel acoustic signatures in a busy estuary. Experimental data recorded in the Hudson River are used for demonstration that cross-correlation method measured the same ship noise and ship noise modulation spectra as conventional methods. The cross-correlation method was then applied for the separation of the acoustic signatures of two ships present simultaneously. Presented methods can be useful for ship traffic monitoring and small ship classification, even in noisy harbor environments.

  17. A Comparative Study of Two Acoustic Measures of Hypernasality

    ERIC Educational Resources Information Center

    Vogel, Adam P.; Ibrahim, Hasherah M.; Reilly, Sheena; Kilpatrick, Nicky

    2009-01-01

    Purpose: This study aimed to compare 2 quantitative acoustic measures of nasality in children with cleft lip and palate (CLP) and healthy controls using formalized perceptual assessment as a guide. Method: Fifty participants (23 children with CLP and 27 age- and gender-matched healthy controls) aged between 4 and 12 years produced a variety of…

  18. Measurement of the total acoustic output power of HITU transducers

    NASA Astrophysics Data System (ADS)

    Jenderka, Klaus-V.; Beissner, Klaus

    2010-03-01

    The majority of High Intensity Therapeutic Ultrasound (HITU) applications use strongly focused ultrasound fields generating very high local intensities in the focal region. The metrology of these high-power ultrasound fields is a challenge for the established measurement procedures and devices. This paper describes the results of measurements by means of the radiation force for a total acoustic output power up to 400 W at 1.5 MHz and up to 200 W at 2.45 MHz. For this purpose, a radiation force balance set-up was adapted for the determination of large acoustic output powers. For two types of HITU transducers, the relationship between the total acoustic output power and the applied net electrical power was determined at close transducer-target distance. Further, dependence of the measured electro-acoustic radiation conductance on the transducer-target distance was investigated at reduced power levels, considering the appearance of focal anomalies. Concluding, a list of the main uncertainty contributions, and an estimate of the uncertainty for the used radiation force balance set-up is given for measurements at high power levels.

  19. Laboratory comparisons of acoustic and optical sensors for microbubble measurement

    NASA Technical Reports Server (NTRS)

    Su, Ming Yang; Todoroff, Douglas; Cartmill, John

    1994-01-01

    This paper presents the results of a recent comparison between three microbubble size spectrum measurement systems. These systems are the light-scattering bubble counter, the photographic bubble-imaging system, and the acoustic resonator array. Good agreement was formed among these three systems over the bubble size range appropriate for each system.

  20. Voice Acoustical Measurement of the Severity of Major Depression

    ERIC Educational Resources Information Center

    Cannizzaro, Michael; Harel, Brian; Reilly, Nicole; Chappell, Phillip; Snyder, Peter J.

    2004-01-01

    A number of empirical studies have documented the relationship between quantifiable and objective acoustical measures of voice and speech, and clinical subjective ratings of severity of Major Depression. To further explore this relationship, speech samples were extracted from videotape recordings of structured interviews made during the…

  1. Measurement of acoustic shielding by a turbulent jet

    NASA Technical Reports Server (NTRS)

    Yu, J. C.; Fratello, D. J.

    1985-01-01

    The acoustic shielding properties of a turbulent jet have been investigated experimentally. The experimental arrangement consisted of an acoustic point source and a turbulent shielding jet. The source and jet parameters investigated include the source frequency, source spectrum, jet velocity, jet heating by simulation and the lateral and longitudinal source positions with respect to the shielding jet. It is found that the maximum sound attenuation provided by the shielding jet depends on the balance between refraction and diffraction. Over the frequency range investigated, the redistribution of sound by the shielding air jet is power conserving. Comparison between measurement and prediction based on an idealized cylindrical uniform jet model indicates that the spreading and decay of the flow field in real jets are important. Comparisons between the present data trends and those reported for jet-by-jet shielding suggest that the major effects observed in the latter are acoustical rather than aerodynamical.

  2. Long-term continuous acoustical suspended-sediment measurements in rivers - Theory, application, bias, and error

    USGS Publications Warehouse

    Topping, David J.; Wright, Scott A.

    2016-05-04

    these sites. In addition, detailed, step-by-step procedures are presented for the general river application of the method.Quantification of errors in sediment-transport measurements made using this acoustical method is essential if the measurements are to be used effectively, for example, to evaluate uncertainty in long-term sediment loads and budgets. Several types of error analyses are presented to evaluate (1) the stability of acoustical calibrations over time, (2) the effect of neglecting backscatter from silt and clay, (3) the bias arising from changes in sand grain size, (4) the time-varying error in the method, and (5) the influence of nonrandom processes on error. Results indicate that (1) acoustical calibrations can be stable for long durations (multiple years), (2) neglecting backscatter from silt and clay can result in unacceptably high bias, (3) two frequencies are likely required to obtain sand-concentration measurements that are unbiased by changes in grain size, depending on site-specific conditions and acoustic frequency, (4) relative errors in silt-and-clay- and sand-concentration measurements decrease substantially as concentration increases, and (5) nonrandom errors may arise from slow changes in the spatial structure of suspended sediment that affect the relations between concentration in the acoustically ensonified part of the cross section and concentration in the entire river cross section. Taken together, the error analyses indicate that the two-frequency method produces unbiased measurements of suspended-silt-and-clay and sand concentration, with errors that are similar to, or larger than, those associated with conventional sampling methods.

  3. Acoustic power measurement of high-intensity focused ultrasound transducer using a pressure sensor.

    PubMed

    Zhou, Yufeng

    2015-03-01

    The acoustic power of high-intensity focused ultrasound (HIFU) is an important parameter that should be measured prior to each treatment to guarantee effective and safe outcomes. A new calibration technique was developed that involves estimating the pressure distribution, calculating the acoustic power using an underwater pressure blast sensor, and compensating the contribution of harmonics to the acoustic power. The output of a clinical extracorporeal HIFU system (center frequency of ~1 MHz, p+ = 2.5-57.2 MPa, p(-) = -1.8 to -13.9 MPa, I(SPPA) = 513-22,940 W/cm(2), -6 dB size of 1.6 × 10 mm: lateral × axial) was measured using this approach and then compared with that obtained using a radiation force balance. Similarities were found between each method at acoustic power ranging from 18.2 W to 912 W with an electrical-to-acoustic conversion efficiency of ~42%. The proposed method has advantages of low weight, smaller size, high sensitivity, quick response, high signal-to-noise ratio (especially at low power output), robust performance, and easy operation of HIFU exposimetry measurement.

  4. Advances in Fast Response Acoustically Derived Air Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Bogoev, Ivan; Jacobsen, Larry; Horst, Thomas; Conrad, Benjamin

    2016-04-01

    Fast-response accurate air-temperature measurements are required when estimating turbulent fluxes of heat, water and carbon dioxide by open-path eddy-covariance technique. In comparison with contact thermometers like thermocouples, ultra-sonic thermometers do not suffer from solar radiation loading, water vapor condensation and evaporative cooling effects. Consequently they have the potential to provide more accurate true air temperature measurements. The absolute accuracy of the ultrasonic thermometer is limited by the following parameters: the distance between the transducer pairs, transducer delays associated with the electrical-acoustic signal conversion that vary with temperature, components of the wind vector that are normal to the ultrasonic paths, and humidity. The distance between the transducer pairs is commonly obtained by coordinate measuring machine. Improved accuracy demonstrated in this study results from increased stiffness in the anemometer head to better maintain the ultrasonic path-length distances. To further improve accuracy and account for changes in transducer delays and distance as a function of temperature, these parameters are characterized in a zero-wind chamber over the entire operating temperature range. When the sonic anemometer is combined with a co-located fast-response water vapor analyzer, like in the IRGASON instrument, speed of sound can be compensated for humidity effects on a point-by-point basis resulting in a true fast-response air temperature measurement. Laboratory test results show that when the above steps are implemented in the calibration of the ultrasonic thermometer air-temperature accuracy better than ±0.5 degrees Celsius can be achieved over the entire operating range. The approach is also validated in a field inter-comparison with an aspirated thermistor probe mounted in a radiation shield.

  5. Measurement resolution of noise directivity patterns from acoustic flight tests

    NASA Technical Reports Server (NTRS)

    Conner, David A.

    1989-01-01

    The measurement resolution of noise directivity patterns from acoustic flight tests was investigated. Directivity angle resolution is affected by the data reduction parameters, the aircraft velocity and flyover altitude, and by deviations of the aircraft from the desired flight path. Equations are developed which determine bounds for the lateral and longitudinal directivity angle resolution as a function of the nominal directivity angle. The equations are applied to a flight test data base and the effects of several flight conditions and data reduction parameters on the directivity angle resolution are presented. The maximum directivity angle resolution typically occurs when the aircraft is at or near the overhead position. In general, directivity angle resolution improves with decreasing velocity, increasing altitude, increasing sampling rate, decreasing block size, and decreasing block averages. Deviations from the desired ideal flight path will increase the resolution. For the flight experiment considered in this study, an average of two flyovers were required at each test condition to obtain an acceptable flight path. The ability of the pilot to maintain the flight track improved with decreasing altitude, decreasing velocity, and practice. Due to the prevailing wind conditions, yaw angles of as much as 20 deg were required to maintain the desired flight path.

  6. Laser and acoustic Doppler techniques for the measurement of fluid velocities

    NASA Technical Reports Server (NTRS)

    Cliff, W. C.

    1975-01-01

    An overview of current laser and acoustic Doppler techniques is presented. Results obtained by Doppler anemometry and conventional sensors are compared. Comparisons include simultaneous velocity measurements by hot wire and a three-dimensional laser anemometer made in a gaseous pipe flow as well as direct comparisons of atmospheric velocities measured with propeller and cup anemometry. Scanning techniques are also discussed. Conclusions and recommendations for future work are presented.

  7. Measurements and computational fluid dynamics predictions of the acoustic impedance of orifices

    NASA Astrophysics Data System (ADS)

    Su, J.; Rupp, J.; Garmory, A.; Carrotte, J. F.

    2015-09-01

    The response of orifices to incident acoustic waves, which is important for many engineering applications, is investigated with an approach combining both experimental measurements and numerical simulations. This paper presents experimental data on acoustic impedance of orifices, which is subsequently used for validation of a numerical technique developed for the purpose of predicting the acoustic response of a range of geometries with moderate computational cost. Measurements are conducted for orifices with length to diameter ratios, L/D, of 0.5, 5 and 10. The experimental data is obtained for a range of frequencies using a configuration in which a mean (or bias) flow passes from a duct through the test orifices before issuing into a plenum. Acoustic waves are provided by a sound generator on the upstream side of the orifices. Computational fluid dynamics (CFD) calculations of the same configuration have also been performed. These have been undertaken using an unsteady Reynolds averaged Navier-Stokes (URANS) approach with a pressure based compressible formulation with appropriate characteristic based boundary conditions to simulate the correct acoustic behaviour at the boundaries. The CFD predictions are in very good agreement with the experimental data, predicting the correct trend with both frequency and orifice L/D in a way not seen with analytical models. The CFD was also able to successfully predict a negative resistance, and hence a reflection coefficient greater than unity for the L / D = 0.5 case.

  8. Periods found in heat measurements obtained by calorimetry

    SciTech Connect

    Jordan, K.C.

    1984-02-28

    During a span of 640 days, a periodicity of 1.5158 +- 0.0008 days was discovered in successive heater equilibria on Calorimeter No. 127. Measurements were taken at 12-h intervals, with occasional changes of exactly 3 or 6 h in the schedule of measurements. This schedule eliminated all other possible periods except a period of 0.150156 days. Periods of 1.519125 and 1.511283 days were discovered in data on the excess length of day as obtained by the US Naval Observatory over a period of 24 y. These two periods could equally well represent periods of 0.150189 and 0.150112 days, since measurements were obtained only once every 24 h. It is suggested that periods observed in sensitive calorimeters and in length of day data may be related. 1 reference, 6 figures, 5 tables.

  9. Field Assessment of Acoustic-Doppler Based Discharge Measurements

    USGS Publications Warehouse

    Mueller, D.S.; ,

    2002-01-01

    The use of equipment based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun a field validation of the instruments currently (2002) available for making discharge measurements from a moving boat in streams of various sizes. Instruments manufactured by SonTek/YSI2 and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made by the use of a Price AA current meter and standard USGS procedures with the acoustic instruments at each site during data collection. The discharges measured with the acoustic instruments were compared with the discharges measured with Price AA meters and the current USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating. Additional analysis of the data collected indicates that the coefficient of variation of the discharge measurements consistently was less for the RD Instruments, Inc. Rio Grandes than it was for the SonTek/YSI RiverSurveyors. The bottom-tracking referenced measurement had a lower coefficient of variation than the differentially corrected global positioning system referenced measurements. It was observed that the higher frequency RiverSurveyors measured a moving bed more often than the lower frequency Rio Grandes. The detection of a moving bed caused RiverSurveyors to be consistently biased low when referenced to bottom tracking. Differentially corrected global positioning system data may be used to remove the bias observed in the bottom-tracking referenced measurements.

  10. The determination of the acoustic parameters of volcanic rocks from compressional velocity measurements

    USGS Publications Warehouse

    Carroll, R.D.

    1969-01-01

    A statistical analysis was made of the relationship of various acoustic parameters of volcanic rocks to compressional wave velocities for data obtained in a volcanic region in Nevada. Some additional samples, chiefly granitic rocks, were also included in the study to extend the range of parameters and the variety of siliceous rock types sampled. Laboratory acoustic measurements obtained on 62 dry core samples were grouped with similar measurements obtained from geophysical logging devices at several depth intervals in a hole from which 15 of the core samples had been obtained. The effects of lithostatic and hydrostatic load on changing the rock acoustic parameters measured in the hole were noticeable when compared with the laboratory measurements on the same core. The results of the analyses determined by grouping all of the data, however, indicate that dynamic Young's, shear and bulk modulus, shear velocity, shear and compressional characteristic impedance, as well as amplitude and energy reflection coefficients may be reliably estimated on the basis of the compressional wave velocities of the rocks investigated. Less precise estimates can be made of density based on the rock compressional velocity. The possible extension of these relationships to include many siliceous rocks is suggested. ?? 1969.

  11. Cosmic sound: Measuring the Universe with baryonic acoustic oscillations

    NASA Astrophysics Data System (ADS)

    Hütsi, Gert

    2006-05-01

    During the last ten to fifteen years cosmology has turned from a data-starved to a data-driven science. Several key parameters of the Universe have now been measured with an accuracy better than 10%. Surprisingly, it has been found that instead of slowing down, the expansion of the Universe proceeds at an ever increasing rate. From this we infer the existence of a negative pressure component -- the so-called Dark Energy (DE) -- that makes up more than two thirds of the total matter-energy content of our Universe. It is generally agreed amongst cosmologists and high energy physicists that understanding the nature of the DE poses one of the biggest challenges for the modern theoretical physics. Future cosmological datasets, being superior in both quantity and quality to currently existing data, hold the promise for unveiling many of the properties of the mysterious DE component. With ever larger datasets, as the statistical errors decrease, one needs to have a very good control over the possible systematic uncertainties. To make progress, one has to concentrate the observational effort towards the phenomena that are theoretically best understood and also least ``contaminated'' by complex astrophysical processes or several intervening foregrounds. Currently by far the cleanest cosmological information has been obtained through measurements of the angular temperature fluctuations of the Cosmic Microwave Background (CMB). The typical angular size of the CMB temperature fluctuations is determined by the distance the sound waves in the tightly coupled baryon-photon fluid can have traveled since the Big Bang until the epoch of recombination. A similar scale is also expected to be imprinted in the large-scale matter distribution as traced by, for instance, galaxies or galaxy clusters. Measurements of the peaks in the CMB angular power spectrum fix the physical scale of the sound horizon with a high precision. By identifying the corresponding features in the low redshift

  12. Nonlinear acoustic measurements ahead of a notch during fatigue

    NASA Astrophysics Data System (ADS)

    Martin, R. W.; Mooers, R. D.; Hutson, A. L.; Sathish, S.; Blodgett, M. P.

    2013-01-01

    This paper presents measurements of relative nonlinear acoustic parameter (βrel), ahead of a notch in Al 7075-T651 dog bone samples, subjected to fatigue. It is compared with crack growth measurements on the same samples. Measurements performed on two samples subjected to identical fatigue conditions that failed at vastly different number of fatigue cycles are described. The βrel measurement for both samples as a function of fatigue cycles was fit a Boltzmann curve. The role of changing βrel ahead of a notch is explored as a possible approach for remain life evaluation.

  13. Acoustic property measurements in a photoacoustic imager

    NASA Astrophysics Data System (ADS)

    Willemink, René G. H.; Manohar, Srirang; Slump, Cornelis H.; van der Heijden, Ferdi; van Leeuwen, Ton

    2007-07-01

    Photoacoustics is a hybrid imaging technique that combines the contrast available to optical imaging with the resolution that is possessed by ultrasound imaging. The technique is based on generating ultrasound from absorbing structures in tissue using pulsed light. In photoacoustic (PA) computerized tomography (CT) imaging, reconstruction of the optical absorption in a subject, is performed for example by filtered backprojection. The backprojection is performed along circular paths in image space instead of along straight lines as in X-ray CT imaging. To achieve this, the speed-of-sound through the subject is usually assumed constant. An unsuitable speed-of-sound can degrade resolution and contrast. We discuss here a method of actually measuring the speed-of- sound distribution using ultrasound transmission through the subject under photoacoustic investigation. This is achieved in a simple approach that does not require any additional ultrasound transmitter. The method uses a passive element (carbon fiber) that is placed in the imager in the path of the illumination which generates ultrasound by the photoacoustic effect and behaves as an ultrasound source. Measuring the time-of-flight of this ultrasound transient by the same detector used for conventional photoacoustics, allows a speed-of-sound image to be reconstructed. This concept is validated on phantoms.

  14. Acoustics and Surface Pressure Measurements from Tandem Cylinder Configurations

    NASA Technical Reports Server (NTRS)

    Hutcheson, Florence V.; Brooks, Thomas F.; Lockard, David P.; Choudhari, Meelan M.; Stead, Daniel J.

    2014-01-01

    Acoustic and unsteady surface pressure measurements from two cylinders in tandem configurations were acquired to study the effect of spacing, surface trip and freestream velocity on the radiated noise. The Reynolds number ranged from 1.15x10(exp 5) to 2.17x10(exp 5), and the cylinder spacing varied between 1.435 and 3.7 cylinder diameters. The acoustic and surface pressure spectral characteristics associated with the different flow regimes produced by the cylinders' wake interference were identified. The dependence of the Strouhal number, peak Sound Pressure Level and spanwise coherence on cylinder spacing and flow velocity was examined. Directivity measurements were performed to determine how well the dipole assumption for the radiation of vortex shedding noise holds for the largest and smallest cylinder spacing tested.

  15. Atypical prosody in Asperger syndrome: perceptual and acoustic measurements.

    PubMed

    Filipe, Marisa G; Frota, Sónia; Castro, São Luís; Vicente, Selene G

    2014-08-01

    It is known that individuals with Asperger syndrome (AS) may show no problems with regard to what is said (e.g., lexical content) but tend to have difficulties in how utterances are produced, i.e., they may show prosodic impairments. In the present study, we focus on the use of prosodic features to express grammatical meaning. Specifically, we explored the sentence type difference between statements and questions that is conveyed by intonation, using perceptual and acoustic measurements. Children aged 8 and 9 years with AS (n = 12) were matched according to age and nonverbal intelligence with typically developing peers (n = 17). Although children with AS could produce categorically accurate prosodic patterns, their prosodic contours were perceived as odd by adult listeners, and acoustic measurements showed alterations in duration and pitch. Additionally, children with AS had greater variability in fundamental frequency contours compared to typically developing peers.

  16. Determining Transmission Loss from Measured External and Internal Acoustic Environments

    NASA Technical Reports Server (NTRS)

    Scogin, Tyler; Smith, A. M.

    2012-01-01

    An estimate of the internal acoustic environment in each internal cavity of a launch vehicle is needed to ensure survivability of Space Launch System (SLS) avionics. Currently, this is achieved by using the noise reduction database of heritage flight vehicles such as the Space Shuttle and Saturn V for liftoff and ascent flight conditions. Marshall Space Flight Center (MSFC) is conducting a series of transmission loss tests to verify and augment this method. For this test setup, an aluminum orthogrid curved panel representing 1/8th of the circumference of a section of the SLS main structure was mounted in between a reverberation chamber and an anechoic chamber. Transmission loss was measured across the panel using microphones. Data measured during this test will be used to estimate the internal acoustic environments for several of the SLS launch vehicle internal spaces.

  17. Acoustic temperature profile measurement technique for large combustion chambers

    NASA Technical Reports Server (NTRS)

    Venkateshan, S. P.; Shakkottai, P.; Kwack, E. Y.; Back, L. H.

    1989-01-01

    Measurement of times of flight of sound waves can be used to determine temperatures in a gas. This paper describes a system, based on this principle, that is capable of giving the temperature profile in a nonisothermal gas volume, for example, prevalent in a large furnace. The apparatus is simple, rugged, accurate, and capable of being automated for process control applications. It is basically an acoustic waveguide where the outside temperature profile is transferred to a chosen gas contained inside the guide.

  18. How to obtain traceability on optical radiation measurements?

    NASA Astrophysics Data System (ADS)

    Matamoros García, Carlos H.

    2006-02-01

    Traceability to national standards provides confidence in measurements results, granting a guaranty when carrying out governmental rules and when demonstrating conformity with quality requirements such as ISO 9000 or ISO/IEC 17025 (and the Mexican equivalent standards). The appropriate traceability contributes with confidence of the quality of products or services. This paper presents different ways to obtain traceability in Mexico for the optical radiation measurements, mentioning some applications, and highlighting the necessity of having traceability to the appropriate units of the SI. Additionally it present the national standards maintained by Centro Nacional de Metrologia (CENAM), the national metrology institute in Mexico, that give the technical support to Mexican measurements in this field and the international recognition that the personal of the Optics and Radiometry Division had gained in 10 years of development.

  19. Flow velocity measurement with the nonlinear acoustic wave scattering

    SciTech Connect

    Didenkulov, Igor; Pronchatov-Rubtsov, Nikolay

    2015-10-28

    A problem of noninvasive measurement of liquid flow velocity arises in many practical applications. To this end the most often approach is the use of the linear Doppler technique. The Doppler frequency shift of signal scattered from the inhomogeneities distributed in a liquid relatively to the emitted frequency is proportional to the sound frequency and velocities of inhomogeneities. In the case of very slow flow one needs to use very high frequency sound. This approach fails in media with strong sound attenuation because acoustic wave attenuation increases with frequency and there is limit in increasing sound intensity, i.e. the cavitation threshold. Another approach which is considered in this paper is based on the method using the difference frequency Doppler Effect for flows with bubbles. This method is based on simultaneous action of two high-frequency primary acoustic waves with closed frequencies on bubbles and registration of the scattered by bubbles acoustic field at the difference frequency. The use of this method is interesting since the scattered difference frequency wave has much lower attenuation in a liquid. The theoretical consideration of the method is given in the paper. The experimental examples confirming the theoretical equations, as well as the ability of the method to be applied in medical diagnostics and in technical applications on measurement of flow velocities in liquids with strong sound attenuation is described. It is shown that the Doppler spectrum form depends on bubble concentration velocity distribution in the primary acoustic beams crossing zone that allows one to measure the flow velocity distribution.

  20. The feasibility of measuring ocean pH by long-range acoustics

    NASA Astrophysics Data System (ADS)

    Worcester, Peter F.

    1989-04-01

    Low frequency (<1000 Hz) sound absorption in the ocean depends exponentially on ocean pH. While the absolute amplitudes measured in long-range (order of 1000 km) acoustic transmission experiments depend in a complex manner on ocean structure and are difficult to interpret without ambiguity, measurements of differential absorption as a function of frequency contain significant information. For surface-reflected rays (RSR) there is the additional factor of frequency-dependent reflectivity. In principle, a comparison of transmitted and received acoustic spectra can be inverted to obtain ocean pH and surface roughness. Calculations performed with preliminary data from a 750-km path in the North Pacific give qualitative agreement with theory (higher frequencies are attenuated more than lower frequencies) but are inadequate for quantitative comparisons (the experiment was not optimized for differential attenuation measurements). Our conclusion is that it is possible, but not easy, to obtain quantitative information on ocean pH and surface roughness from measurements of differential attenuation with frequency along resolved ray paths. To obtain an accuracy of 0.05 in pH with a 750-km transmission at 550+/-100 Hz would require about 100 independent samples for the North Pacific (pH~7.7) and 60 independent samples for the Atlantic (pH~8.0) in order to achieve adequate averaging of amplitude fluctuations induced by internal waves and ambient acoustic noise.

  1. Determining low-frequency source location from acoustic phase measurements

    NASA Astrophysics Data System (ADS)

    Poole, Travis L.; Frisk, George V.

    2002-11-01

    For low-frequency cw sound sources in shallow water, the time rate-of-change of the measured acoustic phase is well approximated by the time rate-of-change of the source-receiver separation distance. An algorithm for determining a locus of possible source locations based on this idea has been developed. The locus has the general form of a hyperbola, which can be used to provide a bearing estimation at long ranges, and an estimate of source location at short ranges. The algorithm uses only acoustic phase data and receiver geometry as input, and can be used even when the source frequency is slightly unstable and/or imprecisely known. The algorithm has been applied to data from low-frequency experiments (20-300 Hz), both for stable and unstable source frequencies, and shown to perform well. [Work supported by ONR and WHOI Academic Programs Office.

  2. Quantitative assessment of articular cartilage with morphologic, acoustic and mechanical properties obtained using high-frequency ultrasound.

    PubMed

    Wang, Shu-Zhe; Huang, Yan-Ping; Saarakkala, Simo; Zheng, Yong-Ping

    2010-03-01

    Osteoarthritis (OA) is one of the most common joint diseases among adults, and its early detection is still not possible. In this study, high-frequency ultrasound and ultrasound-assisted mechanical testing systems were used to quantitatively measure the morphologic, acoustic and mechanical properties of normal and enzymatically degraded bovine articular cartilages in vitro. A total of 40 osteochondral cartilage plugs were prepared from 20 bovine patellae (n=20x2) and divided into two groups for collagenase and trypsin digestions, respectively. A high-frequency ultrasound system (center frequency: 40 MHz) was used to analyze the surface integrity (ultrasound roughness index, URI), thickness and acoustic properties of the articular cartilages before and after enzymatic degradations. Acoustic parameters included the integrated reflection coefficient (IRC) from the cartilage surface, reflection from the cartilage-bone interface (AIB(bone)), integrated attenuation (IA) and integrated backscatter (IBS) of the internal cartilage tissue. A newly developed ultrasound water jet indentation system was used to assess the mechanical properties of the cartilage samples. The results showed that the URI increased significantly (p<0.05) after collagenase digestion while no significant change (p>0.05) was found after trypsin digestion. With regard to acoustic parameters, the IRC decreased significantly (p<0.05) after collagenase digestion while no significant change (p>0.05) was found after trypsin digestion. The AIB(bone) demonstrated an insignificant change after collagenase digestion (p>0.05) but a significant decrease after trypsin digestion (p<0.05). Both enzymatic degradation groups showed insignificant differences (p>0.05) in the IA but a significant increase (p<0.05) in the IBS after both enzymatic degradations. The apparent stiffness measured by ultrasound water jet indentation suggested that articular cartilage from both groups became significantly softer (p<0.05) after

  3. Acoustic Intensity Measurements in the Presence of Low Mach Number Flow

    DTIC Science & Technology

    1993-09-01

    broadband acoustic holography ,3 intensity measurements in the presence of flow,"𔄁𔄀. 7 in-situ evaluation of the acoustic impedance and sound absorption...Cross Spectra" Ph.D. Thesis, Catholic University, (1987). 3. Loyau, T., Pascal, J., Gaillard, P., "Broadband Acoustic Holography Reconstruction From...AD-A269 995 The Pennsylvania State University APPLIED RESEARCH LABORATORY P.O. Box 30 State College, PA 16804 ACOUSTIC INTENSITY MEASUREMENTS IN THE

  4. Correlation of combustor acoustic power levels inferred from internal fluctuating pressure measurements

    NASA Technical Reports Server (NTRS)

    Vonglahn, U. H.

    1978-01-01

    Combustion chamber acoustic power levels inferred from internal fluctuating pressure measurements are correlated with operating conditions and chamber geometries over a wide range. The variables include considerations of chamber design (can, annular, and reverse-flow annular) and size, number of fuel nozzles, burner staging and fuel split, airflow and heat release rates, and chamber inlet pressure and temperature levels. The correlated data include those obtained with combustion component development rigs as well as engines.

  5. Measuring acoustic nonlinearity parameter using collinear wave mixing

    NASA Astrophysics Data System (ADS)

    Liu, Minghe; Tang, Guangxin; Jacobs, Laurence J.; Qu, Jianmin

    2012-07-01

    This study introduces a new acoustic nonlinearity parameter βT. It is shown that βT is associated with the interaction between a longitudinal wave and a shear wave in isotropic elastic solids with quadratic nonlinearity. Experimental measurements are conducted to demonstrate that the collinear wave mixing technique is capable of measuring βT nondestructively. Further, it is shown that βT is well-correlated with the plastic deformation in Al-6061 alloys. These results indicate that collinear wave mixing is a promising method for nondestructive assessment of plastic deformation, and possibly, fatigue damage in metallic materials.

  6. A novel multipitch measurement algorithm for acoustic signals of moving targets

    NASA Astrophysics Data System (ADS)

    Huang, Jingchang; Guo, Feng; Zu, Xingshui; Li, Haiyan; Liu, Huawei; Li, Baoqing

    2016-12-01

    In this paper, a novel multipitch measurement (MPM) method is proposed for acoustic signals. Starting from the analysis of moving targets' acoustic signatures, a pitch-based harmonics representation model of acoustic signal is put forward. According to the proposed harmonics model, a modified greatest common divisor (MGCD) method is developed to obtain an initial multipitch set (IMS). Subsequently, the harmonic number vector (HNV) associated with the IMS is determined by maximizing the objective function formulated as a multi-impulse-train weighted symmetric average magnitude sum function (SAMSF) of the observed signal. The frequencies of SAMSF are determined by the target acoustic signal, the periods of the multi-impulse-train are governed by the estimated IMS harmonics and the maximization of the objective function is figured out through a time-domain matching of periodicities of the multi-impulse-train with that of the SAMSF. Finally, by using the obtained IMS and its HNV, a precise fundamental frequency set is achieved. Evaluation of the algorithm performances in comparison with state-of-the-art methods indicates that MPM is practical for the multipitch extraction of moving targets.

  7. Evaluation of disfluent speech by means of automatic acoustic measurements.

    PubMed

    Lustyk, Tomas; Bergl, Petr; Cmejla, Roman

    2014-03-01

    An experiment was carried out to determine whether the level of the speech fluency disorder can be estimated by means of automatic acoustic measurements. These measures analyze, for example, the amount of silence in a recording or the number of abrupt spectral changes in a speech signal. All the measures were designed to take into account symptoms of stuttering. In the experiment, 118 audio recordings of read speech by Czech native speakers were employed. The results indicate that the human-made rating of the speech fluency disorder in read speech can be predicted on the basis of automatic measurements. The number of abrupt spectral changes in the speech segments turns out to be the most appropriate measure to describe the overall speech performance. The results also imply that there are measures with good results describing partial symptoms (especially fixed postures without audible airflow).

  8. Velocity measurements in whole blood using acoustic resolution photoacoustic Doppler

    PubMed Central

    Brunker, Joanna; Beard, Paul

    2016-01-01

    Acoustic resolution photoacoustic Doppler velocimetry promises to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Despite successful implementation using blood-mimicking fluids, measurements in blood have proved challenging, thus preventing in vivo application. A common explanation for this difficulty is that whole blood is insufficiently heterogeneous relative to detector frequencies of tens of MHz compatible with deep tissue photoacoustic measurements. Through rigorous experimental measurements we provide new insight that refutes this assertion. We show for the first time that, by careful choice of the detector frequency and field-of-view, and by employing novel signal processing methods, it is possible to make velocity measurements in whole blood using transducers with frequencies in the tens of MHz range. These findings have important implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions. PMID:27446707

  9. Comparison of multi-microphone transfer matrix measurements with acoustic network models of swirl burners

    NASA Astrophysics Data System (ADS)

    Fischer, A.; Hirsch, C.; Sattelmayer, T.

    2006-11-01

    Utilizing the close analogy between electronic circuits and ducted acoustic systems, mathematical methods originally developed for the characterization of electronic networks are applied to the experimental acoustic plane wave characterization of swirl burners with complex geometries. The experiments presented in the paper show that the acoustic behavior of swirl generators can be quantitatively evaluated treating them as acoustic two-ports. Such acoustic two-ports are presented in forms of transfer-, scattering- and mobility matrices of the element. In the acoustic burner study dynamic pressure measurements were made at several locations of a tubular combustor test rig for two acoustically independent states, which were generated by forcing with sirens at the opposite ends of the setup. The technique for the experimental evaluation of acoustic transfer matrices of complex geometries on the basis of these dynamic pressure measurements is illustrated. As an alternative to the experiment, the evaluation of the acoustic behavior of acoustic systems is assessed using acoustic networks consisting of simple acoustic elements like ducts, bends, junctions and sudden area changes with transfer matrices, which are derived from first principles. In the paper, a network model representing the transfer characteristics of swirl burners is presented and compared with the previously measured transfer matrices. Although the burner geometry is rather complex, its acoustic behavior can be successfully mapped to a network consisting of a serial connection of nine elements with only minor adjustment of one parameter.

  10. An Acoustic Measure for Word Prominence in Spontaneous Speech

    PubMed Central

    Wang, Dagen; Narayanan, Shrikanth

    2010-01-01

    An algorithm for automatic speech prominence detection is reported in this paper. We describe a comparative analysis on various acoustic features for word prominence detection and report results using a spoken dialog corpus with manually assigned prominence labels. The focus is on features such as spectral intensity and speech rate that are directly extracted from speech based on a correlation-based approach without requiring explicit linguistic or phonetic knowledge. Additionally, various pitch-based measures are studied with respect to their discriminating ability for prominence detection. A parametric scheme for modeling pitch plateau is proposed and this feature alone is found to outperform the traditional local pitch statistics. Two sets of experiments are used to explore the usefulness of the acoustic score generated using these features. The first set focuses on a more traditional way of word prominence detection based on a manually-tagged corpus. A 76.8% classification accuracy was achieved on a corpus of role-playing spoken dialogs. Due to difficulties in manually tagging speech prominence into discrete levels (categories), the second set of experiments focuses on evaluating the score indirectly. Specifically, through experiments on the Switchboard corpus, it is shown that the proposed acoustic score can discriminate between content word and function words in a statistically significant way. The relation between speech prominence and content/function words is also explored. Since prominent words tend to be predominantly content words, and since content words can be automatically marked from text-derived part of speech (POS) information, it is shown that the proposed acoustic score can be indirectly cross-validated through POS information. PMID:20454538

  11. Diffraction correction for precision surface acoustic wave velocity measurements

    NASA Astrophysics Data System (ADS)

    Ruiz M., Alberto; Nagy, Peter B.

    2002-09-01

    Surface wave dispersion measurements can be used to nondestructively characterize shot-peened, laser shock-peened, burnished, and otherwise surface-treated specimens. In recent years, there have been numerous efforts to separate the contribution of surface roughness from those of near-surface material variations, such as residual stress, texture, and increased dislocation density. As the accuracy of the dispersion measurements was gradually increased using state-of-the-art laser-ultrasonic scanning and sophisticated digital signal processing methods, it was recognized that a perceivable dispersive effect, similar to the one found on rough shot-peened specimens, is exhibited by untreated smooth surfaces as well. This dispersion effect is on the order of 0.1%, that is significantly higher than the experimental error associated with the measurements and comparable to the expected velocity change produced by near-surface compressive residual stresses in metals below their yield point. This paper demonstrates that the cause of this apparent dispersion is the diffraction of the surface acoustic wave (SAW) as it travels over the surface of the specimen. The results suggest that a diffraction correction may be introduced to increase the accuracy of surface wave dispersion measurements. A simple diffraction correction model was developed for surface waves and this correction was subsequently validated by laser-interferometric velocity measurements on aluminum specimens. copyright 2002 Acoustical Society of America.

  12. Extending acoustic data measured with small-scale supersonic model jets to practical aircraft exhaust jets

    NASA Astrophysics Data System (ADS)

    Kuo, Ching-Wen

    2010-06-01

    Modern military aircraft jet engines are designed with variable geometry nozzles to provide optimum thrust in different operating conditions within the flight envelope. However, the acoustic measurements for such nozzles are scarce, due to the cost involved in making full-scale measurements and the lack of details about the exact geometry of these nozzles. Thus the present effort at The Pennsylvania State University and the NASA Glenn Research Center, in partnership with GE Aviation, is aiming to study and characterize the acoustic field produced by supersonic jets issuing from converging-diverging military style nozzles. An equally important objective is to develop a scaling methodology for using data obtained from small- and moderate-scale experiments which exhibits the independence of the jet sizes to the measured noise levels. The experimental results presented in this thesis have shown reasonable agreement between small-scale and moderate-scale jet acoustic data, as well as between heated jets and heat-simulated ones. As the scaling methodology is validated, it will be extended to using acoustic data measured with small-scale supersonic model jets to the prediction of the most important components of full-scale engine noise. When comparing the measured acoustic spectra with a microphone array set at different radial locations, the characteristics of the jet noise source distribution may induce subtle inaccuracies, depending on the conditions of jet operation. A close look is taken at the details of the noise generation region in order to better understand the mismatch between spectra measured at various acoustic field radial locations. A processing methodology was developed to correct the effect of the noise source distribution and efficiently compare near-field and far-field spectra with unprecedented accuracy. This technique then demonstrates that the measured noise levels in the physically restricted space of an anechoic chamber can be appropriately

  13. The effect of artificial rain on backscattered acoustic signal: first measurements

    NASA Astrophysics Data System (ADS)

    Titchenko, Yuriy; Karaev, Vladimir; Meshkov, Evgeny; Goldblat, Vladimir

    The problem of rain influencing on a characteristics of backscattered ultrasonic and microwave signal by water surface is considered. The rain influence on backscattering process of electromagnetic waves was investigated in laboratory and field experiments, for example [1-3]. Raindrops have a significant impact on backscattering of microwave and influence on wave spectrum measurement accuracy by string wave gauge. This occurs due to presence of raindrops in atmosphere and modification of the water surface. For measurements of water surface characteristics during precipitation we propose to use an acoustic system. This allows us obtaining of the water surface parameters independently on precipitation in atmosphere. The measurements of significant wave height of water surface using underwater acoustical systems are well known [4, 5]. Moreover, the variance of orbital velocity can be measure using these systems. However, these methods cannot be used for measurements of slope variance and the other second statistical moments of water surface that required for analyzing the radar backscatter signal. An original design Doppler underwater acoustic wave gauge allows directly measuring the surface roughness characteristics that affect on electromagnetic waves backscattering of the same wavelength [6]. Acoustic wave gauge is Doppler ultrasonic sonar which is fixed near the bottom on the floating disk. Measurements are carried out at vertically orientation of sonar antennas towards water surface. The first experiments were conducted with the first model of an acoustic wave gauge. The acoustic wave gauge (8 mm wavelength) is equipped with a transceiving antenna with a wide symmetrical antenna pattern. The gauge allows us to measure Doppler spectrum and cross section of backscattered signal. Variance of orbital velocity vertical component can be retrieved from Doppler spectrum with high accuracy. The result of laboratory and field experiments during artificial rain is presented

  14. Comparison between Measurements Obtained with three Different Perineometers

    PubMed Central

    Barbosa, Patrícia Brentegani; Franco, Maíra Menezes; de Oliveira Souza, Flaviane; Antônio, Flávia Ignácio; Montezuma, Thaís; Ferreira, Cristine Homsi Jorge

    2009-01-01

    OBJECTIVE: To analyze the results obtained in the evaluation of intra-vaginal pressure using three different brands of perineometers in nulliparous volunteers. MATERIALS AND METHODS: Twenty nulliparous women with no anatomical alterations and/or dysfunction of the pelvic floor were enrolled in our study. All the women had the ability to voluntarily contract their PFM (Pelvic Floor Muscles), as assessed by digital palpation. The intra-vaginal pressure was assessed using three different brands of perineometer (Neurodyn Evolution™, SensuPower™ and Peritron™). Each volunteer was evaluated on three alternate days by a single examiner using a single brand of perineometer on each day. In the assessment, the volunteers were required to pull (contract) their PFM in and up as strongly as possible 3 times and to sustain the contraction for 5 seconds, with an interval of 30 seconds between each pull. For the statistical analysis, a concordance correlation coefficient was used to compare the values that were obtained with each brand of perineometer. RESULTS: A moderate concordance (0.51) was found between the results from the Peritron™ and Neurodyn™ perineometers, a fair concordance (0.21) between the Peritron™ and SensuPower™ brands and a poor concordance (0.19) between the Neurodyn™ and SensuPower™ brands. CONCLUSION: The concordance of the measurements of the intra-vaginal pressure ranged from poor to moderate, suggesting that perineometers of different brands generate different results. PMID:19578656

  15. Noise in small portable motocompressors. Experiments on limited-cost acoustic treatments to obtain progressive improvements

    NASA Astrophysics Data System (ADS)

    Collober, J.; Corlay, B.

    1984-04-01

    Design modifications are proposed in order to help motocompressor manufacturers to reduce the noise level to 85 dBA. Work on 8kW groups shows that the noise sources are, in order of importance, the internal combustion motor exhaust, the air inlet, the cooling air circuit and the oil pan. The effects of an inlet air filter, an exhaust noise attenuator and a cover on the motocompressor are discussed. A noise reduction of 10dBA is obtained.

  16. Acoustic measurement of the Deepwater Horizon Macondo well flow rate

    PubMed Central

    Camilli, Richard; Di Iorio, Daniela; Bowen, Andrew; Reddy, Christopher M.; Techet, Alexandra H.; Yoerger, Dana R.; Whitcomb, Louis L.; Seewald, Jeffrey S.; Sylva, Sean P.; Fenwick, Judith

    2012-01-01

    On May 31, 2010, a direct acoustic measurement method was used to quantify fluid leakage rate from the Deepwater Horizon Macondo well prior to removal of its broken riser. This method utilized an acoustic imaging sonar and acoustic Doppler sonar operating onboard a remotely operated vehicle for noncontact measurement of flow cross-section and velocity from the well’s two leak sites. Over 2,500 sonar cross-sections and over 85,000 Doppler velocity measurements were recorded during the acquisition process. These data were then applied to turbulent jet and plume flow models to account for entrained water and calculate a combined hydrocarbon flow rate from the two leak sites at seafloor conditions. Based on the chemical composition of end-member samples collected from within the well, this bulk volumetric rate was then normalized to account for contributions from gases and condensates at initial leak source conditions. Results from this investigation indicate that on May 31, 2010, the well’s oil flow rate was approximately 0.10 ± 0.017 m3 s-1 at seafloor conditions, or approximately 85 ± 15 kg s-1 (7.4 ± 1.3 Gg d-1), equivalent to approximately 57,000 ± 9,800 barrels of oil per day at surface conditions. End-member chemical composition indicates that this oil release rate was accompanied by approximately an additional 24 ± 4.2 kg s-1 (2.1 ± 0.37 Gg d-1) of natural gas (methane through pentanes), yielding a total hydrocarbon release rate of 110 ± 19 kg s-1 (9.5 ± 1.6 Gg d-1). PMID:21903931

  17. Acoustic measurement of the Deepwater Horizon Macondo well flow rate.

    PubMed

    Camilli, Richard; Di Iorio, Daniela; Bowen, Andrew; Reddy, Christopher M; Techet, Alexandra H; Yoerger, Dana R; Whitcomb, Louis L; Seewald, Jeffrey S; Sylva, Sean P; Fenwick, Judith

    2012-12-11

    On May 31, 2010, a direct acoustic measurement method was used to quantify fluid leakage rate from the Deepwater Horizon Macondo well prior to removal of its broken riser. This method utilized an acoustic imaging sonar and acoustic Doppler sonar operating onboard a remotely operated vehicle for noncontact measurement of flow cross-section and velocity from the well's two leak sites. Over 2,500 sonar cross-sections and over 85,000 Doppler velocity measurements were recorded during the acquisition process. These data were then applied to turbulent jet and plume flow models to account for entrained water and calculate a combined hydrocarbon flow rate from the two leak sites at seafloor conditions. Based on the chemical composition of end-member samples collected from within the well, this bulk volumetric rate was then normalized to account for contributions from gases and condensates at initial leak source conditions. Results from this investigation indicate that on May 31, 2010, the well's oil flow rate was approximately 0.10 ± 0.017 m(3) s(-1) at seafloor conditions, or approximately 85 ± 15 kg s(-1) (7.4 ± 1.3 Gg d(-1)), equivalent to approximately 57,000 ± 9,800 barrels of oil per day at surface conditions. End-member chemical composition indicates that this oil release rate was accompanied by approximately an additional 24 ± 4.2 kg s(-1) (2.1 ± 0.37 Gg d(-1)) of natural gas (methane through pentanes), yielding a total hydrocarbon release rate of 110 ± 19 kg s(-1) (9.5 ± 1.6 Gg d(-1)).

  18. Measurement of stiffness of standing trees and felled logs using acoustics: A review.

    PubMed

    Legg, Mathew; Bradley, Stuart

    2016-02-01

    This paper provides a review on the use of acoustics to measure stiffness of standing trees, stems, and logs. An outline is given of the properties of wood and how these are related to stiffness and acoustic velocity throughout the tree. Factors are described that influence the speed of sound in wood, including the different types of acoustic waves which propagate in tree stems and lumber. Acoustic tools and techniques that have been used to measure the stiffness of wood are reviewed. The reasons for a systematic difference between direct and acoustic measurements of stiffness for standing trees, and methods for correction, are discussed. Other techniques, which have been used in addition to acoustics to try to improve stiffness measurements, are also briefly described. Also reviewed are studies which have used acoustic tools to investigate factors that influence the stiffness of trees. These factors include different silvicultural practices, geographic and environmental conditions, and genetics.

  19. Measurement of food texture by an acoustic vibration method

    NASA Astrophysics Data System (ADS)

    Sakurai, Naoki; Taniwaki, Mitsuru; Iwatani, Shin-ichiro; Akimoto, Hidemi

    2011-09-01

    Food texture was measured by a new acoustic vibration method. A piezoelectric sensor sandwiched between a probe and piston was inserted into a food sample by delivery of silicon oil to a cylinder by a pump. Vibration emitted from the food sample on insertion of the probe was monitored by voltage outputs of the sensor. The voltage signals were passed through 19 half octave bands to calculate texture index for each band. The texture index was defined as vibration energy of the probe caused by the food rupture and/or breakage per unit time.

  20. Passive Wake Acoustics Measurements at Denver International Airport

    NASA Technical Reports Server (NTRS)

    Wang, Frank Y.; Wassaf, Hadi; Dougherty, Robert P.; Clark, Kevin; Gulsrud, Andrew; Fenichel, Neil; Bryant, Wayne H.

    2004-01-01

    From August to September 2003, NASA conducted an extensive measurement campaign to characterize the acoustic signal of wake vortices. A large, both spatially as well as in number of elements, phased microphone array was deployed at Denver International Airport for this effort. This paper will briefly describe the program background, the microphone array, as well as the supporting ground-truth and meteorological sensor suite. Sample results to date are then presented and discussed. It is seen that, in the frequency range processed so far, wake noise is generated predominantly from a very confined area around the cores.

  1. Design and Implementation of an Acoustic X-ray Detector to Measure the LCLS Beam Energy

    SciTech Connect

    Loos, Jennifer L.; /San Jose State U. /SLAC

    2010-08-25

    On April 11, 2009, first light was seen from LCLS. The present apparatus being used to measure the x-ray beam energy is the Total Energy Sensor which uses a suite of thermal sensors. Another device is needed to cross-check the energy measurements. This new diagnostic tool utilizes radiation acoustic phenomena to determine the x-ray beam energy. A target is hit by the x-rays from the beam, and a voltage is generated in two piezoelectric sensors attached to the target in response to the consequent deformation. Once the voltage is known, the power can be obtained. Thermal sensors will also be attached to the target for calibration purposes. Material selection and design were based on: durability, ultra-high vacuum compatibility, safety and thermal properties. The target material was also chosen for its acoustic properties which were determined from tests using a frequency generator and laser. Initial tests suggest the device will function as anticipated.

  2. Determination of rotor harmonic blade loads from acoustic measurements

    NASA Technical Reports Server (NTRS)

    Kasper, P. K.

    1975-01-01

    The magnitude of discrete frequency sound radiated by a rotating blade is strongly influenced by the presence of a nonuniform distribution of aerodynamic forces over the rotor disk. An analytical development and experimental results are provided for a technique by which harmonic blade loads are derived from acoustic measurements. The technique relates, on a one-to-one basis, the discrete frequency sound harmonic amplitudes measured at a point on the axis of rotation to the blade-load harmonic amplitudes. This technique was applied to acoustic data from two helicopter types and from a series of test results using the NASA-Langley Research Center rotor test facility. The inferred blade-load harmonics for the cases considered tended to follow an inverse power law relationship with harmonic blade-load number. Empirical curve fits to the data showed the harmonic fall-off rate to be in the range of 6 to 9 db per octave of harmonic order. These empirical relationships were subsequently used as input data in a compatible far field rotational noise prediction model. A comparison between predicted and measured off-axis sound harmonic levels is provided for the experimental cases considered.

  3. Analysis of acoustic reduction using spectral similarity measures.

    PubMed

    Hämäläinen, Annika; Gubian, Michele; ten Bosch, Louis; Boves, Lou

    2009-12-01

    Articulatory and acoustic reduction can manifest itself in the temporal and spectral domains. This study introduces a measure of spectral reduction, which is based on the speech decoding techniques commonly used in automatic speech recognizers. Using data for four frequent Dutch affixes from a large corpus of spontaneous face-to-face conversations, it builds on an earlier study examining the effects of lexical frequency on durational reduction in spoken Dutch [Pluymaekers, M. et al. (2005). J. Acoust. Soc. Am. 118, 2561-2569], and compares the proposed measure of spectral reduction with duration as a measure of reduction. The results suggest that the spectral reduction scores capture other aspects of reduction than duration. While duration can--albeit to a moderate degree--be predicted by a number of linguistically motivated variables (such as word frequency, segmental context, and speech rate), the spectral reduction scores cannot. This suggests that the spectral reduction scores capture information that is not directly accounted for by the linguistically motivated variables. The results also show that the spectral reduction scores are able to predict a substantial amount of the variation in duration that the linguistically motivated variables do not account for.

  4. Wideband acoustic immittance measures: developmental characteristics (0 to 12 months).

    PubMed

    Kei, Joseph; Sanford, Chris A; Prieve, Beth A; Hunter, Lisa L

    2013-07-01

    Rapid developmental changes of the peripheral auditory system in normal infants occur in the first year of life. Specifically, the postnatal development of the external and middle ear affects all measures of external and middle ear function including wideband acoustic immittance(WAI). This article provides an overview of WAI studies in newborns and infants from a developmental perspective. Normative WAI data in newborns are fairly consistent across studies. However, there are discrepancies in some WAI measures between studies, possibly due to differences in sampling, methodology, and instrumentation. Accuracy of WAI measurements is compromised when a good probe seal cannot be maintained during testing or an inaccurate estimate of the cross-sectional area of the ear canal of newborns occurs. Comparison of WAI data between age groups from 0 to 12 months reveals maturation effects. Additional age-specific longitudinal and cross-sectional normative WAI data for infants from birth to 12 months are required to validate and consolidate existing data.

  5. Classification of heart valve condition using acoustic measurements

    SciTech Connect

    Clark, G.

    1994-11-15

    Prosthetic heart valves and the many great strides in valve design have been responsible for extending the life spans of many people with serious heart conditions. Even though the prosthetic valves are extremely reliable, they are eventually susceptible to long-term fatigue and structural failure effects expected from mechanical devices operating over long periods of time. The purpose of our work is to classify the condition of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of heart valve sounds. The structural failures of interest for Bscc valves is called single leg separation (SLS). SLS can occur if the outlet strut cracks and separates from the main structure of the valve. We measure acoustic opening and closing sounds (waveforms) using high sensitivity contact microphones on the patient`s thorax. For our analysis, we focus our processing and classification efforts on the opening sounds because they yield direct information about outlet strut condition with minimal distortion caused by energy radiated from the valve disc.

  6. Turbulent Diffusivity under High Winds from Acoustic Measurements of Bubbles

    NASA Astrophysics Data System (ADS)

    Wang, D. W.; Wijesekera, H. W.; Jarosz, E.; Teague, W. J.; Pegau, W. S.

    2015-12-01

    Breaking surface waves generate layers of bubble clouds as air parcels entrain into the upper-ocean by the action of turbulent motions. The turbulent diffusivity in the bubble cloud layer was investigated by combining measurements of surface winds, waves, bubble acoustic backscatter, currents, and hydrography. These measurements were made at water depths of 60-90 m on the shelf of the Gulf of Alaska near Kayak Island during late December 2012, a period where the ocean was experiencing winds and significant wave heights up to 22 m s-1 and 9 m, respectively. Vertical profiles of acoustic backscatter decayed exponentially from the wave surface with e-folding lengths of about 0.6 to 6 m, while the bubble penetration depths were about 3 to 30 m. Both e-folding lengths and bubble depths were highly correlated with surface wind and wave conditions. The turbulent diffusion coefficients, inferred from e-folding length and bubble depth, varied from about 0.01 m2 s-1 to 0.4 m2 s-1. Our analysis suggests that the turbulent diffusivity in the bubble layer can be parameterized as a function of the cube of the wind friction velocity with a proportionality coefficient that depends weakly on wave age. Furthermore, in the bubble layer, on average, the shear production of the turbulent kinetic energy estimated by the diffusion coefficients was a similar order magnitude as the dissipation rate predicted by the wall boundary-layer theory.

  7. Measurements of Low-Frequency Acoustic Attenuation in Soils.

    DTIC Science & Technology

    2007-11-02

    Engineering Research Laboratory to design an acoustic subsurface imaging system, a set of experiments was conducted in which the attenuation and the velocity...support of the U.S. Army Construction Engineering Research Laboratory’s efforts to design an acoustic subsurface imaging system which would ideally be...of acoustic waves such as those generated by a subsurface imaging system. An experiment reported in the literature characterized the acoustic

  8. Modeling and Measuring Acoustic Backscatter from Fish Aggregations

    DTIC Science & Technology

    1999-09-30

    of the abundance, spatial distribution, schooling behaviour and acoustic backscatter of the Namibian pilchard. Cruise Report 99-4, Dr. Fridtjof ... Nansen . 103 pp. Rudstam, L, Horne, J., Fleischer, G. Report from the Great Lakes Acoustic Workshop III: Translation of acoustic data to fish abundance

  9. Low-temperature acoustic properties of nanostructured zirconium obtained by intensive plastic deformation

    NASA Astrophysics Data System (ADS)

    Vatazhuk, E. N.; Pal-Val, P. P.; Natsik, V. D.; Pal-Val, L. N.; Tikhonovsky, M. A.; Velikodny, A. N.; Khaimovich, P. A.

    2011-02-01

    The temperature dependences of the logarithmic decrement and dynamic Young's modulus of polycrystalline coarse-grained and nanostructured Zr are studied at temperatures of 2.5-340K. A nanostructured state of samples with grain sizes on the order of 100nm was produced by intensive plastic deformation (IPD). The measurements were made using a two-component vibrator technique at frequencies of 73-350kHz. A relaxation peak in the internal friction near 250K was discovered in the coarse-grained, annealed Zr which is retained after IPD, but its height increases by roughly a factor of 10 and the localization temperature shifts to lower values. In addition, after IPD a new internal friction peak shows up at moderately low temperatures near 80K. The activation parameters for the observed peaks are estimated and it is shown that they arise from different thermally activated dislocation processes: interactions of dislocations with impurities and kink pair formation in dislocations. It was found that IPD is accompanied by a significant (1-8%) reduction in the Young's modulus because of quasistatic and dynamic dislocation effects. A glass-like anomaly appears in the temperature dependence of the Young's modulus of nanostructured Zr at T <20K which may be determined by tunnelling and thermally activated relaxation of quasilocal excitations.

  10. Optimizing stepwise rotation of dodecahedron sound source to improve the accuracy of room acoustic measures.

    PubMed

    Martellotta, Francesco

    2013-09-01

    Dodecahedron sound sources are widely used for acoustical measurement purposes as they produce a good approximation of omnidirectional radiation. Evidence shows that such an assumption is acceptable only in the low-frequency range (namely below 1 kHz), while at higher frequencies sound radiation is far from being uniform. In order to improve the accuracy of acoustical measurements obtained from dodecahedron sources, international standard ISO 3382 suggests an averaging of results after a source rotation. This paper investigates the effects of such rotations, both in terms of variations in acoustical parameters and spatial distribution of sound reflections. Taking advantage of a spherical microphone array, the different reflection patterns were mapped as a function of source rotation, showing that some reflections may be considerably attenuated for different aiming directions. This paper investigates the concept of averaging results while changing rotation angles and the minimum number of rotations required to improve the accuracy of the average value. Results show that averages of three measurements carried out at 30° angular steps are closer to actual values and show much less fluctuation. In addition, an averaging of the directional intensity components of the selected responses stabilizes the spatial distribution of the reflections.

  11. Measurement and Characterization of Space Shuttle Solid Rocket Motor Plume Acoustics

    NASA Technical Reports Server (NTRS)

    Kenny, Robert Jeremy

    2009-01-01

    NASA's current models to predict lift-off acoustics for launch vehicles are currently being updated using several numerical and empirical inputs. One empirical input comes from free-field acoustic data measured at three Space Shuttle Reusable Solid Rocket Motor (RSRM) static firings. The measurements were collected by a joint collaboration between NASA - Marshall Space Flight Center, Wyle Labs, and ATK Launch Systems. For the first time NASA measured large-thrust solid rocket motor plume acoustics for evaluation of both noise sources and acoustic radiation properties. Over sixty acoustic free-field measurements were taken over the three static firings to support evaluation of acoustic radiation near the rocket plume, far-field acoustic radiation patterns, plume acoustic power efficiencies, and apparent noise source locations within the plume. At approximately 67 m off nozzle centerline and 70 m downstream of the nozzle exit plan, the measured overall sound pressure level of the RSRM was 155 dB. Peak overall levels in the far field were over 140 dB at 300 m and 50-deg off of the RSRM thrust centerline. The successful collaboration has yielded valuable data that are being implemented into NASA's lift-off acoustic models, which will then be used to update predictions for Ares I and Ares V liftoff acoustic environments.

  12. Acoustic Environment of Admiralty Inlet: Broadband Noise Measurements

    SciTech Connect

    Xu, Jinshan; Deng, Zhiqun; Martinez, Jayson J.; Carlson, Thomas J.; Myers, Joshua R.; Weiland, Mark A.; Jones, Mark E.

    2011-09-30

    Admiralty Inlet has been selected as a potential tidal energy site. It is located near shipping lanes, is a highly variable acoustic environment, and is frequented by the highly endangered southern resident killer whale (SRKW). Resolving environmental impacts is the first step to receiving approval to deploy tidal turbines at Admiralty Inlet. Of particular concern is the potential for blade strike or other negative interactions between the SRKW and the tidal turbine. A variety of technologies including passive and active monitoring systems are being considered as potential tools to determine the presence of SRKW in the vicinity of the turbines. Broadband noise level measurements are critical for the determination of design and operation specifications of all marine and hydrokinetic energy capture technologies. Acoustic environment data at the proposed site was acquired at different depths using a cabled vertical line array (VLA) with four calibrated hydrophones. The sound pressure level (SPL) power spectrum density was estimated based on the fast Fourier transform. This study describes the first broadband SPL measurements for this site at different depths with frequency ranging from 10 kHz to 480 kHz in combination with other information. To understand the SPL caused by this bedload transport, three different pressure sensors with temperature and conductivity were also assembled on the VLA to measure the conditions at the hydrophone deployment depth. The broadband SPL levels at frequency ranges of 3 kHz to 7 kHz as a function of depth were estimated. Only the hydrophone at an average depth of 40 m showed the strong dependence of SPL with distance from the bottom, which was possibly caused by the cobbles shifting on the seabed. Automatic Identification System data were also studied to understand the SPL measurements.

  13. Measured acoustic properties of variable and low density bulk absorbers

    NASA Technical Reports Server (NTRS)

    Dahl, M. D.; Rice, E. J.

    1985-01-01

    Experimental data were taken to determine the acoustic absorbing properties of uniform low density and layered variable density samples using a bulk absober with a perforated plate facing to hold the material in place. In the layered variable density case, the bulk absorber was packed such that the lowest density layer began at the surface of the sample and progressed to higher density layers deeper inside. The samples were placed in a rectangular duct and measurements were taken using the two microphone method. The data were used to calculate specific acoustic impedances and normal incidence absorption coefficients. Results showed that for uniform density samples the absorption coefficient at low frequencies decreased with increasing density and resonances occurred in the absorption coefficient curve at lower densities. These results were confirmed by a model for uniform density bulk absorbers. Results from layered variable density samples showed that low frequency absorption was the highest when the lowest density possible was packed in the first layer near the exposed surface. The layers of increasing density within the sample had the effect of damping the resonances.

  14. Regularization method for measurement of structural intensity using nearfield acoustical holography.

    PubMed

    Saijyou, Kenji; Okawara, Chiaki

    2005-04-01

    The regularization method for measurement of structural intensity using nearfield acoustical holography is proposed. Spatial derivatives of normal displacement are necessary to obtain the structural intensity. The derivative operations amplify high-wave-number components of measurement noise. Therefore, the estimation of an appropriate wave-number filter is crucial for implementation of the measurement of structural intensity. In conventional methods, this wave-number filter is determined from the flexural wavelength. And the same wave-number filter is applied to obtain all spatial derivatives. As a result, structural intensity obtained from the pressure hologram, whose signal-to-noise ratio is low, is seriously contaminated by the noise. To overcome this difficulty, regularization theory is applied to determine the appropriate wave-number filter for each order of derivatives. The effectiveness of the proposed method is demonstrated by experiments.

  15. An Ultrasonic Caliper Device for Measuring Acoustic Nonlinearity

    NASA Astrophysics Data System (ADS)

    Hunter, Christopher; Sapozhnikov, Oleg A.; Maxwell, Adam D.; Khokhlova, Vera A.; Wang, Yak-Nam; MacConaghy, Brian; Kreider, Wayne

    In medical and industrial ultrasound, it is often necessary to measure the acoustic properties of a material. A specific medical application requires measurements of sound speed, attenuation, and nonlinearity to characterize livers being evaluated for transplantation. For this application, a transmission-mode caliper device is proposed in which both transmit and receive transducers are directly coupled to a test sample, the propagation distance is measured with an indicator gage, and receive waveforms are recorded for analysis. In this configuration, accurate measurements of nonlinearity present particular challenges: diffraction effects can be considerable while nonlinear distortions over short distances typically remain small. To enable simple estimates of the nonlinearity coeffcient from a quasi-linear approximation to the lossless Burgers' equation, the calipers utilize a large transmitter and plane waves are measured at distances of 15-50 mm. Waves at 667 kHz and pressures between 0.1 and 1 MPa were generated and measured in water at different distances; the nonlinearity coeffcient of water was estimated from these measurements with a variability of approximately 10%. Ongoing efforts seek to test caliper performance in other media and improve accuracy via additional transducer calibrations.

  16. Acoustics

    NASA Technical Reports Server (NTRS)

    Goodman, Jerry R.; Grosveld, Ferdinand

    2007-01-01

    The acoustics environment in space operations is important to maintain at manageable levels so that the crewperson can remain safe, functional, effective, and reasonably comfortable. High acoustic levels can produce temporary or permanent hearing loss, or cause other physiological symptoms such as auditory pain, headaches, discomfort, strain in the vocal cords, or fatigue. Noise is defined as undesirable sound. Excessive noise may result in psychological effects such as irritability, inability to concentrate, decrease in productivity, annoyance, errors in judgment, and distraction. A noisy environment can also result in the inability to sleep, or sleep well. Elevated noise levels can affect the ability to communicate, understand what is being said, hear what is going on in the environment, degrade crew performance and operations, and create habitability concerns. Superfluous noise emissions can also create the inability to hear alarms or other important auditory cues such as an equipment malfunctioning. Recent space flight experience, evaluations of the requirements in crew habitable areas, and lessons learned (Goodman 2003; Allen and Goodman 2003; Pilkinton 2003; Grosveld et al. 2003) show the importance of maintaining an acceptable acoustics environment. This is best accomplished by having a high-quality set of limits/requirements early in the program, the "designing in" of acoustics in the development of hardware and systems, and by monitoring, testing and verifying the levels to ensure that they are acceptable.

  17. Application of acoustic doppler velocimeters for streamflow measurements

    USGS Publications Warehouse

    Rehmel, M.

    2007-01-01

    The U.S. Geological Survey (USGS) principally has used Price AA and Price pygmy mechanical current meters for measurement of discharge. New technologies have resulted in the introduction of alternatives to the Price meters. One alternative, the FlowTracker acoustic Doppler velocimeter, was designed by SonTek/YSI to make streamflow measurements in wadeable conditions. The device measures a point velocity and can be used with standard midsection method algorithms to compute streamflow. The USGS collected 55 quality-assurance measurements with the FlowTracker at 43 different USGS streamflow-gaging stations across the United States, with mean depths from 0.05to0.67m, mean velocities from 13 to 60 cm/s, and discharges from 0.02 to 12.4m3/s. These measurements were compared with Price mechanical current meter measurements. Analysis of the comparisons shows that the FlowTracker discharges were not statistically different from the Price meter discharges at a 95% confidence level. ?? 2007 ASCE.

  18. Acoustic measurement method of the volume flux of a seafloor hydrothermal plume

    NASA Astrophysics Data System (ADS)

    Xu, G.; Jackson, D. R.; Bemis, K. G.; Rona, P. A.

    2011-12-01

    Measuring fluxes (volume, chemical, heat, etc.) of the deep sea hydrothermal vents has been a crucial but challenging task faced by the scientific community since the discovery of the vent systems. However, the great depths and complexities of the hydrothermal vents make traditional sampling methods laborious and almost daunting missions. Furthermore, the samples, in most cases both sparse in space and sporadic in time, are hardly enough to provide a result with moderate uncertainty. In September 2010, our Cabled Observatory Vent Imaging Sonar System (COVIS, http://vizlab.rutgers.edu/AcoustImag/covis.html) was connected to the Neptune Canada underwater ocean observatory network (http://www.neptunecanada.ca) at the Main Endeavour vent field on the Endeavour segment of the Juan de Fuca Ridge. During the experiment, the COVIS system produced 3D images of the buoyant plume discharged from the vent complex Grotto by measuring the back-scattering intensity of the acoustic signal. Building on the methodology developed in our previous work, the vertical flow velocity of the plume is estimated from the Doppler shift of the acoustic signal using geometric correction to compensate for the ambient horizontal currents. A Gaussian distribution curve is fitted to the horizontal back-scattering intensity profile to determine the back-scattering intensity at the boundary of the plume. Such a boundary value is used as the threshold in a window function for separating the plume from background signal. Finally, the volume flux is obtained by integrating the resulting 2D vertical velocity profile over the horizontal cross-section of the plume. In this presentation, we discuss preliminary results from the COVIS experiment. In addition, several alternative approaches are applied to determination of the accuracy of the estimated plume vertical velocity in the absence of direct measurements. First, the results from our previous experiment (conducted in 2000 at the same vent complex using a

  19. Measurement of ultrasonic power and electro-acoustic efficiency of high power transducers.

    PubMed

    Lin, S; Zhang, F

    2000-01-01

    In this paper, an improved method for the measurement of acoustic power and electro-acoustic efficiency of high power ultrasonic transducers is presented. The measuring principle is described, the experimental results are given. In comparison with traditional methods, the method presented in this paper has the advantages of simplicity, economy and practicality. The most important is that it can measure the output acoustic power and the electro-acoustic efficiency of the transducer under the condition of high power and practical applications, such as ultrasonic cleaning and soldering.

  20. International Congress on Acoustic Intensity Measurement: Measurement Techniques and Applications, 2nd, Senlis, France, September 23-26, 1985, Proceedings

    NASA Astrophysics Data System (ADS)

    Recent developments in acoustic-intensity measurement are discussed in reviews and reports of theoretical and experimental investigations. Instrumentation, vector acoustics, sound radiation, intensity in the presence of flow, intensity in structures, sound power, source localization, impedance, absorption, and transmission are the fields covered by the contributions. Specific topics addressed include microphone configurations for intensity probes, the rotational structure of intensity fields, acoustic intensity and numerical simulation, sound-power measurement in the presence of background noise, and techniques for measuring the absorption coefficient of acoustic materials. Graphs, drawings, diagrams, tables of numerical data, and photographs of test setups are provided.

  1. Determination of particle size distributions from acoustic wave propagation measurements

    SciTech Connect

    Spelt, P.D.; Norato, M.A.; Sangani, A.S.; Tavlarides, L.L.

    1999-05-01

    The wave equations for the interior and exterior of the particles are ensemble averaged and combined with an analysis by Allegra and Hawley [J. Acoust. Soc. Am. {bold 51}, 1545 (1972)] for the interaction of a single particle with the incident wave to determine the phase speed and attenuation of sound waves propagating through dilute slurries. The theory is shown to compare very well with the measured attenuation. The inverse problem, i.e., the problem of determining the particle size distribution given the attenuation as a function of frequency, is examined using regularization techniques that have been successful for bubbly liquids. It is shown that, unlike the bubbly liquids, the success of solving the inverse problem is limited since it depends strongly on the nature of particles and the frequency range used in inverse calculations. {copyright} {ital 1999 American Institute of Physics.}

  2. Effects of ingested atmospheric turbulence on measured tail rotor acoustics

    NASA Technical Reports Server (NTRS)

    Signor, David B.; Yamauchi, Gloria K.; Mosher, Marianne; Hagen, Martin J.; George, Albert R.

    1992-01-01

    Results from an outdoor hover test of a full-scale Lynx tail rotor are presented. The investigation was designed to further the understanding of the acoustics of an isolated tail rotor hovering out-of-ground effect in atmospheric turbulence, without the effects of the main rotor wake or other helicopter components. Measurements include simultaneous rotor performance, noise, inflow, and far-field atmospheric turbulence. Results with grid-generated inflow turbulence are also presented. The effects of turbulence ingestion on rotor noise are quantified. Turbulence ingestion noise is found to be the dominant noise mechanism at locations near the rotor axis. At these locations, the sound radiated by the hovering rotor increases with both increasing atmospheric wind speed and ingested rms turbulent velocity.

  3. Measurements of atmospheric turbulence effects on tail rotor acoustics

    NASA Technical Reports Server (NTRS)

    Hagen, Martin J.; Yamauchi, Gloria K.; Signor, David B.; Mosher, Marianne

    1994-01-01

    Results from an outdoor hover test of a full-scale Lynx tail rotor are presented. The investigation was designed to further the understanding of the acoustics of an isolated tail rotor hovering out-of-ground effect in atmospheric turbulence, without the effects of the main rotor wake or other helicopter components. Measurements include simultaneous rotor performance, noise, inflow, and far-field atmospheric turbulence. Results with grid-generated inflow turbulence are also presented. The effects of atmospheric turbulence ingestion on rotor noise are quantified. In contradiction to current theories, increasing rotor inflow and rotor thrust were found to increase turbulence ingestion noise. This is the final report of Task 13A--Helicopter Tail Rotor Noise, of the NASA/United Kingdom Defense Research Agency cooperative Aeronautics Research Program.

  4. Pulsed electro-acoustic (PEA) measurements of embedded charge distributions

    NASA Astrophysics Data System (ADS)

    Dennison, J. R.; Pearson, Lee H.

    2013-09-01

    Knowledge of the spatial distribution and evolution of embedded charge in thin dielectric materials has important applications in semiconductor, high-power electronic device, high-voltage DC power cable insulation, high-energy and plasma physics apparatus, and spacecraft industries. Knowing how, where, and how much charge accumulates and how it redistributes and dissipates can predict destructive charging effects. Pulsed Electro-acoustic (PEA) measurements— and two closely related methods, Pressure Wave Propagation (PWP) and Laser Intensity Modulation (LIMM)— nondestructively probe such internal charge distributions. We review the instrumentation, methods, theory and signal processing of simple PEA experiments, as well as the related PPW and LIMM methods. We emphasize system improvements required to achieve high spatial resolution for in vacuo measurements of thin dielectrics charged using electron beam injection.

  5. Surface Acoustic Wave Vibration Sensors for Measuring Aircraft Flutter

    NASA Technical Reports Server (NTRS)

    Wilson, William C.; Moore, Jason P.; Juarez, Peter D.

    2016-01-01

    Under NASA's Advanced Air Vehicles Program the Advanced Air Transport Technology (AATT) Project is investigating flutter effects on aeroelastic wings. To support that work a new method for measuring vibrations due to flutter has been developed. The method employs low power Surface Acoustic Wave (SAW) sensors. To demonstrate the ability of the SAW sensor to detect flutter vibrations the sensors were attached to a Carbon fiber-reinforced polymer (CFRP) composite panel which was vibrated at six frequencies from 1Hz to 50Hz. The SAW data was compared to accelerometer data and was found to resemble sine waves and match each other closely. The SAW module design and results from the tests are presented here.

  6. Measurement of the Acoustic Nonlinearity Parameter for Biological Media.

    NASA Astrophysics Data System (ADS)

    Cobb, Wesley Nelson

    In vitro measurements of the acoustic nonlinearity parameter are presented for several biological media. With these measurements it is possible to predict the distortion of a finite amplitude wave in biological tissues of current diagnostic and research interest. The measurement method is based on the finite amplitude distortion of a sine wave that is emmitted by a piston source. The growth of the second harmonic component of this wave is measured by a piston receiver which is coaxial with and has the same size as the source. The experimental measurements and theory are compared in order to determine the nonlinearity parameter. The density, sound speed, and attenuation for the medium are determined in order to make this comparison. The theory developed for this study accounts for the influence of both diffraction and attenuation on the experimental measurements. The effects of dispersion, tissue inhomogeneity and gas bubbles within the excised tissues are studied. To test the measurement method, experimental results are compared with established values for the nonlinearity parameter of distilled water, ethylene glycol and glycerol. The agreement between these values suggests that the measurement uncertainty is (+OR-) 5% for liquids and (+OR-) 10% for solid tissues. Measurements are presented for dog blood and bovine serum albumen as a function of concentration. The nonlinearity parameters for liver, kidney and spleen are reported for both human and canine tissues. The values for the fresh tissues displayed little variation (6.8 to 7.8). Measurements for fixed, normal and cirrhotic tissues indicated that the nonlinearity parameter does not depend strongly on pathology. However, the values for fixed tissues were somewhat higher than those of the fresh tissues.

  7. Numerical investigation and electro-acoustic modeling of measurement methods for the in-duct acoustical source parameters.

    PubMed

    Jang, Seung-Ho; Ih, Jeong-Guon

    2003-02-01

    It is known that the direct method yields different results from the indirect (or load) method in measuring the in-duct acoustic source parameters of fluid machines. The load method usually comes up with a negative source resistance, although a fairly accurate prediction of radiated noise can be obtained from any method. This study is focused on the effect of the time-varying nature of fluid machines on the output results of two typical measurement methods. For this purpose, a simplified fluid machine consisting of a reservoir, a valve, and an exhaust pipe is considered as representing a typical periodic, time-varying system and the measurement situations are simulated by using the method of characteristics. The equivalent circuits for such simulations are also analyzed by considering the system as having a linear time-varying source. It is found that the results from the load method are quite sensitive to the change of cylinder pressure or valve profile, in contrast to those from the direct method. In the load method, the source admittance turns out to be predominantly dependent on the valve admittance at the calculation frequency as well as the valve and load admittances at other frequencies. In the direct method, however, the source resistance is always positive and the source admittance depends mainly upon the zeroth order of valve admittance.

  8. Measurement of Bubble Size Distribution Based on Acoustic Propagation in Bubbly Medium

    NASA Astrophysics Data System (ADS)

    Wu, Xiongjun; Hsiao, Chao-Tsung; Choi, Jin-Keun; Chahine, Georges

    2013-03-01

    Acoustic properties are strongly affected by bubble size distribution in a bubbly medium. Measurement of the acoustic transmission becomes increasingly difficulty as the void fraction of the bubbly medium increases due to strong attenuation, while acoustic reflection can be measured more easily with increasing void fraction. The ABS ACOUSTIC BUBBLE SPECTROMETER®\\copyright, an instrument for bubble size measurement that is under development tries to take full advantage of the properties of acoustic propagation in bubbly media to extract bubble size distribution. Properties of both acoustic transmission and reflection in the bubbly medium from a range of short single-frequency bursts of acoustic waves at different frequencies are measured in an effort to deduce the bubble size distribution. With the combination of both acoustic transmission and reflection, assisted with validations from photography, the ABS ACOUSTIC BUBBLE SPECTROMETER®\\copyright has the potential to measure bubble size distributions in a wider void fraction range. This work was sponsored by Department of Energy SBIR program

  9. In-situ geophysical measurements in marine sediments: Applications in seafloor acoustics and paleoceanography

    NASA Astrophysics Data System (ADS)

    Gorgas, Thomas Joerg

    Acoustic in-situ sound speeds and attenuation were measured on the Eel River shelf, CA, with the Acoustic Lance between 5 and 15 kHz to 2.0 meters below seafloor (mbsf). A comparison with laboratory ultrasonic geoacoustic data obtained at 400 kHz on cored sediments showed faster in-situ and ultrasonic sound speeds in coarse-grained deposits in water depths to 60 m than in fine-grained deposits below that contour line. Ultrasonic attenuation was often greater than in-situ values and remained almost constant below 0.4 mbsf in these heterogeneous deposits. In-situ attenuation decreased with depth. These observations partly agree with results from other field studies, and with theoretical models that incorporate intergranular friction and dispersion from viscosity as main controls on acoustic wave propagation in marine sediments. Deviations among in-situ and laboratory acoustic data from the Eel Margin with theoretical studies were linked to scattering effects. Acoustic Lance was also deployed in homogeneous, fine-grained sediments on the inner shelf of SE Korea, where free gas was identified in late-September, but not in mid-September 1999. Free gas was evidenced by an abrupt decrease of in-situ sound speed and by characteristic changes in acoustic waveforms. These results suggest the presence of a gassy sediment layer as shallow as 2 mbsf along the 70 m bathymetry line, and was attributed to a variable abundance of free gas on short-term and/or small-regional scales on the SE Korea shelf. Bulk density variations in marine sediments obtained along the Walvis Ridge/Basin, SW Africa, at Ocean Drilling Program (ODP) Sites 1081 to 1084 were spectral-analyzed to compute high-resolution sedimentation rates (SRs) in both the time- and age domains by correctly identifying Milankovitch cycles (MCs). SRs for the ODP sites yielded age-depth models that often correlate positively with biostratigraphic data and with organic mass accumulation rates (MAR Corg), a proxy for

  10. Acoustic measurements of F-16 aircraft operating in hush house, NSN 4920-02-070-2721

    NASA Astrophysics Data System (ADS)

    Miller, V. R.; Plzak, G. A.; Chinn, J. M.

    1981-09-01

    The purpose of this test program was to measure the acoustic environment in the hush house facility located at Kelly Air Force Base, Texas, during operation of the F-16 aircraft to ensure that aircraft structural acoustic design limits were not exceeded. The acoustic measurements showed that no sonic fatigue problems are anticipated with the F-16 aircraft aft fuselage structure during operation in the hush house. The measured acoustic levels were less than those measured in an F-16 aircraft water cooled hush house at Hill AFB, but were increased over that measured during ground run up. It was recommended that the acoustic loads measured in this program should be specified in the structural design criteria for aircraft which will be subjected to hush house operation or defining requirements for associated equipment.

  11. Interpreting measurements obtained with the cloud absorption radiometer

    NASA Technical Reports Server (NTRS)

    1988-01-01

    The software developed for the analysis of data from the Cloud Absorption Radiometer (CAR) is discussed. The CAR is a multichannel radiometer designed to measure the radiation field in the middle of an optically thick cloud (the diffusion domain). It can also measure the surface albedo and escape function. The instrument currently flies on a C-131A aircraft operated by the University of Washington. Most of this data was collected during the First International satellite cloud climatology project Regional Experiment (FIRE) Marine Stratocumulus Intensive Field Observation program off San Diego during July 1987. Earlier flights of the CAR have also been studied.

  12. Outcomes Measurement in Voice Disorders: Application of an Acoustic Index of Dysphonia Severity

    ERIC Educational Resources Information Center

    Awan, Shaheen N.; Roy, Nelson

    2009-01-01

    Purpose: The purpose of this experiment was to assess the ability of an acoustic model composed of both time-based and spectral-based measures to track change following voice disorder treatment and to serve as a possible treatment outcomes measure. Method: A weighted, four-factor acoustic algorithm consisting of shimmer, pitch sigma, the ratio of…

  13. Model helicopter rotor high-speed impulsive noise: Measured acoustics and blade pressures

    NASA Technical Reports Server (NTRS)

    Boxwell, D. A.; Schmitz, F. H.; Splettstoesser, W. R.; Schultz, K. J.

    1983-01-01

    A 1/17-scale research model of the AH-1 series helicopter main rotor was tested. Model-rotor acoustic and simultaneous blade pressure data were recorded at high speeds where full-scale helicopter high-speed impulsive noise levels are known to be dominant. Model-rotor measurements of the peak acoustic pressure levels, waveform shapes, and directively patterns are directly compared with full-scale investigations, using an equivalent in-flight technique. Model acoustic data are shown to scale remarkably well in shape and in amplitude with full-scale results. Model rotor-blade pressures are presented for rotor operating conditions both with and without shock-like discontinuities in the radiated acoustic waveform. Acoustically, both model and full-scale measurements support current evidence that above certain high subsonic advancing-tip Mach numbers, local shock waves that exist on the rotor blades ""delocalize'' and radiate to the acoustic far-field.

  14. Tracking and Characterization of Aircraft Wakes Using Acoustic and Lidar Measurements

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Humphreys, William M., Jr.

    2005-01-01

    Data from the 2003 Denver International Airport Wake Acoustics Test are further examined to discern spectral content of aircraft wake signatures, and to compare three dimensional wake tracking from acoustic data to wake tracking data obtained through use of continuous wave and pulsed lidar. Wake tracking data derived from acoustic array data agree well with both continuous wave and pulsed lidar in the horizontal plane, but less well with pulsed lidar in the vertical direction. Results from this study show that the spectral distribution of acoustic energy in a wake signature varies greatly with aircraft type.

  15. Challenges in obtaining reliable measurements of point rainfall

    NASA Astrophysics Data System (ADS)

    Sieck, Lisa C.; Burges, Stephen J.; Steiner, Matthias

    2007-01-01

    Extensive data recorded from storm systems passing over the well-instrumented 21.4 km2 Goodwin Creek watershed in northern Mississippi are used to highlight uncertainties associated with the measurement of surface rainfall, focusing on data quality control, gauge calibration, out-of-level gauge orifices, and wind effects on rain gauge catch. Assessment of the wind effect on gauge catch is central to the presented analyses, including an in-depth evaluation of a recent technique for estimating the rainfall undercatch by means of wind and raindrop size information. Our findings emphasize that quantification of the wind effect on rain gauge catch is difficult because of uncertainties associated with measuring rainfall, drop size distribution, and the wind at gauge rim height. On the basis of our evaluation the sophisticated wind effect correction technique that makes use of raindrop size and wind information is much less effective than traditional methods based on rainfall rate and wind observations alone.

  16. Passive Acoustic Tomography Tested for Measuring Gas Temperatures

    NASA Technical Reports Server (NTRS)

    Fralick, Gustave C.; Kleppe, John

    2004-01-01

    The requirements of higher performance, better fuel economy, and lower emissions place an increasing premium on knowing the internal operating parameters of jet engines. One of the most important is the gas temperature in the post combustor section of the engine. Typically the gas temperature is measured with a thermocouple probe or by some optical technique such as Rayleigh scattering. Probes, while providing valuable information, have several limitations. The probe signal must be corrected for radiation and conduction losses, probes provide only a point measurement, and probes must be constructed of materials whose melting points are lower than the temperature of the environment into which they are inserted. Some of the disadvantages of probes are overcome by various optical techniques. Nothing needs to be inserted into the flow, and the temperature can be directly related to the signal by known physical laws. However, optical techniques require optical access (i.e., a window) and a light source (such as a laser), and they are very sensitive to the presence of particles in the flow. To overcome these problems, researchers from the NASA Glenn Research Center and The University of Nevada are developing a technique that uses sound instead of light to measure gas temperature. Like optical techniques, it is nonintrusive--no probe need be exposed to the combustion environment--and the temperature is directly related to a measured quantity--the speed of sound, which is proportional to the square root of the absolute temperature. The temperature profile inside the engine is constructed from the differences in arrival time between correlated signals from an array of microphones placed around the circumference of the engine. In much the same way as a complete picture of the inside of your body can be constructed from an array of x-ray photographs taken at different angles, the temperature profile in the engine is constructed from the angular array of microphones. It is

  17. Acoustic Measurements of an Uninstalled Spacecraft Cabin Ventilation Fan Prototype

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; Brown, Clifford A.; Shook, Tony D.; Winkel, James; Kolacz, John S.; Podboy, Devin M.; Loew, Raymond A.; Mirecki, Julius H.

    2012-01-01

    Sound pressure measurements were recorded for a prototype of a spacecraft cabin ventilation fan in a test in the NASA Glenn Acoustical Testing Laboratory. The axial fan is approximately 0.089 m (3.50 in.) in diameter and 0.223 m (9.00 in.) long and has nine rotor blades and eleven stator vanes. At design point of 12,000 rpm, the fan was predicted to produce a flow rate of 0.709 cu m/s (150 cfm) and a total pressure rise of 925 Pa (3.72 in. of water) at 12,000 rpm. While the fan was designed to be part of a ducted atmospheric revitalization system, no attempt was made to throttle the flow or simulate the installed configuration during this test. The fan was operated at six speeds from 6,000 to 13,500 rpm. A 13-microphone traversing array was used to collect sound pressure measurements along two horizontal planes parallel to the flow direction, two vertical planes upstream of the fan inlet and two vertical planes downstream of the fan exhaust. Measurements indicate that sound at blade passing frequency harmonics contribute significantly to the overall audible noise produced by the fan at free delivery conditions.

  18. Unrestrained acoustic plethysmograph for measuring tidal volume in mice.

    PubMed

    Reynolds, Jeffrey S; Frazer, David G

    2006-09-01

    The traditional method for measurement of tidal volume in unrestrained mice relies on pressure changes induced by a freely respiring animal in a whole body plethysmograph. These changes have been assumed to be the result of thermo-hygrometric differences between respired air and gas within the chamber. It is known, however, that gas compression in the lung can also contribute significantly to changes in plethysmograph pressure. This study describes an acoustic plethysmograph for mice that is capable of measuring the tidal volume time series without the errors associated with the traditional method. The plethysmograph was designed as a resonating cavity at a fixed frequency. It had a sharp resonant peak and was tuned so that changes in body volume produced nearly linear changes in sound amplitude. The plethysmograph was tested with a water filled balloon connected to a syringe pump. The volume of the balloon was varied as a triangle wave with an amplitude of 250 microL. The RMS error between measured and delivered volume was 4.43 microL. A volume step test, performed to assess the response time of the system, showed that the plethysmograph responded in less than one millisecond.

  19. Experimental and Theoretical Measurements of Concentration Distributions in Acoustic Focusing Devices

    SciTech Connect

    Rose, K A; Fisher, K; Jung, B; Ness, K; Mariella Jr., R P

    2008-06-16

    We describe a modeling approach to capture the particle motion within an acoustic focusing microfluidic device. Our approach combines finite element models for the acoustic forces with analytical models for the fluid motion and uses these force fields to calculate the particle motion in a Brownian dynamics simulation. We compare results for the model with experimental measurements of the focusing efficiency within a microfabricated device. The results show good qualitative agreement over a range of acoustic driving voltages and particle sizes.

  20. Evaluation of acoustic emission technique for crack growth measurement in aeronautical structures

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; Davis, W. T.

    1974-01-01

    An investigation has been conducted concerning the possibility to use the acoustic emission technique for the measurement of fatigue crack growth in aluminum alloy specimens. Two types of aluminum alloys were tested in the investigation. It was found that the acoustic emission technique provides a reliable indication of changes in the crack dimensions over relatively short periods of time. The level of acoustic activity serves as an indicator of the size of the cracks.

  1. Measurement results obtained from air quality monitoring system

    SciTech Connect

    Turzanski, P.K.; Beres, R.

    1995-12-31

    An automatic system of air pollution monitoring operates in Cracow since 1991. The organization, assembling and start-up of the network is a result of joint efforts of the US Environmental Protection Agency and the Cracow environmental protection service. At present the automatic monitoring network is operated by the Provincial Inspection of Environmental Protection. There are in total seven stationary stations situated in Cracow to measure air pollution. These stations are supported continuously by one semi-mobile (transportable) station. It allows to modify periodically the area under investigation and therefore the 3-dimensional picture of creation and distribution of air pollutants within Cracow area could be more intelligible.

  2. Measurement of transmission loss characteristics using acoustic intensity techniques at the KU-FRL Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    Roskam, J.

    1983-01-01

    The transmission loss characteristics of panels using the acoustic intensity technique is presented. The theoretical formulation, installation of hardware, modifications to the test facility, and development of computer programs and test procedures are described. A listing of all the programs is also provided. The initial test results indicate that the acoustic intensity technique is easily adapted to measure transmission loss characteristics of panels. Use of this method will give average transmission loss values. The fixtures developed to position the microphones along the grid points are very useful in plotting the intensity maps of vibrating panels.

  3. Application of SH surface acoustic waves for measuring the viscosity of liquids in function of pressure and temperature.

    PubMed

    Kiełczyński, P; Szalewski, M; Balcerzak, A; Rostocki, A J; Tefelski, D B

    2011-12-01

    Viscosity measurements were carried out on triolein at pressures from atmospheric up to 650 MPa and in the temperature range from 10°C to 40°C using ultrasonic measuring setup. Bleustein-Gulyaev SH surface acoustic waves waveguides were used as viscosity sensors. Additionally, pressure changes occurring during phase transition have been measured over the same temperature range. Application of ultrasonic SH surface acoustic waves in the liquid viscosity measurements at high pressure has many advantages. It enables viscosity measurement during phase transitions and in the high-pressure range where the classical viscosity measurement methods cannot operate. Measurements of phase transition kinetics and viscosity of liquids at high pressures and various temperatures (isotherms) is a novelty. The knowledge of changes in viscosity in function of pressure and temperature can help to obtain a deeper insight into thermodynamic properties of liquids.

  4. Thomson scattering measurements of heat flux from ion-acoustic waves in laser-produced aluminum plasmas.

    PubMed

    Yu, Q Z; Zhang, J; Li, Y T; Lu, X; Hawreliak, J; Wark, J; Chambers, D M; Wang, Z B; Yu, C X; Jiang, X H; Li, W H; Liu, S Y; Zheng, Z J

    2005-04-01

    Thomson scattering (TS) measurements are performed at different locations in a laser-produced aluminum plasma. Variations of the separation, wavelength shift, and asymmetric distribution of the two ion-acoustic waves are investigated from their spectral-time-resolved TS images. Detailed information on the space-time evolution of the plasma parameters is obtained. Electron distribution and variation of the heat flux in the plasma are also obtained for a steep temperature gradient.

  5. Acoustic resolution photoacoustic Doppler velocity measurements in fluids using time-domain cross-correlation

    NASA Astrophysics Data System (ADS)

    Brunker, J.; Beard, P.

    2013-03-01

    Blood flow measurements have been demonstrated using the acoustic resolution mode of photoacoustic sensing. This is unlike previous flowmetry methods using the optical resolution mode, which limits the maximum penetration depth to approximately 1mm. Here we describe a pulsed time correlation photoacoustic Doppler technique that is inherently flexible, lending itself to both resolution modes. Doppler time shifts are quantified via cross-correlation of pairs of photoacoustic waveforms generated in moving absorbers using pairs of laser light pulses, and the photoacoustic waves detected using an ultrasound transducer. The acoustic resolution mode is employed by using the transducer focal width, rather than the large illuminated volume, to define the lateral spatial resolution. The use of short laser pulses allows depth-resolved measurements to be obtained with high spatial resolution, offering the prospect of mapping flow within microcirculation. Whilst our previous work has been limited to a non-fluid phantom, we now demonstrate measurements in more realistic blood-mimicking phantoms incorporating fluid suspensions of microspheres flowing along an optically transparent tube. Velocities up to 110 mm/s were measured with accuracies approaching 1% of the known velocities, and resolutions of a few mm/s. The velocity range and resolution are scalable with excitation pulse separation, but the maximum measurable velocity was considerably smaller than the value expected from the detector focal beam width. Measurements were also made for blood flowing at velocities up to 13.5 mm/s. This was for a sample reduced to 5% of the normal haematocrit; increasing the red blood cell concentration limited the maximum measurable velocity so that no results were obtained for concentrations greater than 20% of a physiologically realistic haematocrit. There are several possible causes for this limitation; these include the detector bandwidth and irregularities in the flow pattern. Better

  6. Resonant Acoustic Measurement of Vapor Phase Transport Phenomenon

    NASA Astrophysics Data System (ADS)

    Schuhmann, R. J.; Garrett, S. L.; Matson, J. V.

    2002-12-01

    A major impediment to accurate non steady-state diffusion measurements is the ability to accurately measure and track a rapidly changing gas concentration without disturbing the system. Non-destructive methods that do not interfere with system dynamics have been developed in the past. These methods, however, have tended to be cumbersome or inaccurate at low concentrations. A new experimental approach has been developed to measure gaseous diffusion in free air and through porous materials. The method combines the traditional non steady-state laboratory methodology with resonant acoustic gas analysis. A phase-locked-loop (PLL) resonance frequency tracker is combined with a thermally insulated copper resonator. A piston sealed with a metal bellows excites the fundamental standing wave resonance of the resonator. The PLL maintains a constant phase difference (typically 90§) between the accelerometer mounted on the piston and a microphone near the piston to track the resonance frequency in real time. A capillary or glass bead filled core is fitted into an o-ring sealed opening at the end of the resonator opposite the bellows. The rate at which the tracer gas is replaced by air within the resonator is controlled by the diffusion coefficient of the gas in free air through the capillary (DA) or by the effective diffusion coefficient of the gas through the core (De). The mean molecular weight of the gas mixture in the resonator is directly determined six times each minute from the ratio of the absolute temperature to the square of the fundamental acoustic resonance frequency. Average system stability (temperature divided by frequency squared) is better than 350 ppm. DA values for a 0.3-inch diameter capillary were in excellent agreement with published values. De values for porous media samples (0.5 mm glass beads) of four different lengths (1 through 4 inches) using three different tracer gases (He, CH4, Kr) will be reported. Comments will be offered regarding tracer gas

  7. Aerobot measurements successfully obtained during Solo Spirit Balloon Mission

    NASA Astrophysics Data System (ADS)

    Avidson, Raymond E.; Bowman, Judd D.; Guinness, Edward A.; Johnson, Sarah S.; Slavney, S. H.; Stein, Thomas C.; Bachelder, Aaron D.; Cameron, Jonathan M.; Cutts, James A.; Ivlev, Robert V.; Kahn, Ralph A.

    Robotic balloons, also known as aerobots, have become candidates for collecting atmospheric data and detailed surface observations of Venus, Mars, and Titan. A mission to Venus over a decade ago used two of them. Their inclusion last year in attempts by a balloonist to circumnavigate the Earth aptly demonstrated their utility for remote sensing and in situ observations of planetary atmospheres.To simulate aspects of an aerobot mission, a small payload to measure local atmospheric conditions and balloon position and velocity was included on Solo Spirit “Round the World” flights during January and August of last year. These missions, flown in Roziere balloons, were attempts by Steve Fossett to become the first person to circumnavigate the globe in a balloon without stopping. Neither attempt was successful, but the aerobot came through with flying colors.

  8. Helium measurements of pore-fluids obtained from SAFOD drillcore

    SciTech Connect

    Ali, S.; Stute, M.; Torgersen, T.; Winckler, G.; Kennedy, B.M.

    2010-04-15

    {sup 4}He accumulated in fluids is a well established geochemical tracer used to study crustal fluid dynamics. Direct fluid samples are not always collectable; therefore, a method to extract rare gases from matrix fluids of whole rocks by diffusion has been adapted. Helium was measured on matrix fluids extracted from sandstones and mudstones recovered during the San Andreas Fault Observatory at Depth (SAFOD) drilling in California, USA. Samples were typically collected as subcores or from drillcore fragments. Helium concentration and isotope ratios were measured 4-6 times on each sample, and indicate a bulk {sup 4}He diffusion coefficient of 3.5 {+-} 1.3 x 10{sup -8} cm{sup 2}s{sup -1} at 21 C, compared to previously published diffusion coefficients of 1.2 x 10{sup -18} cm{sup 2}s{sup -1} (21 C) to 3.0 x 10{sup -15} cm{sup 2}s{sup -1} (150 C) in the sands and clays. Correcting the diffusion coefficient of {sup 4}He{sub water} for matrix porosity ({approx}3%) and tortuosity ({approx}6-13) produces effective diffusion coefficients of 1 x 10{sup -8} cm{sup 2}s{sup -1} (21 C) and 1 x 10{sup -7} (120 C), effectively isolating pore fluid {sup 4}He from the {sup 4}He contained in the rock matrix. Model calculations indicate that <6% of helium initially dissolved in pore fluids was lost during the sampling process. Complete and quantitative extraction of the pore fluids provide minimum in situ porosity values for sandstones 2.8 {+-} 0.4% (SD, n=4) and mudstones 3.1 {+-} 0.8% (SD, n=4).

  9. Thick Films acoustic sensors devoted to MTR environment measurements. Thick Films acoustic sensors devoted to Material Testing Reactor environment measurements

    SciTech Connect

    Very, F.; Rosenkrantz, E.; Combette, P.; Ferrandis, J.Y.; Fourmentel, D.; Destouches, C.; Villard, J.F.

    2015-07-01

    The development of advanced instrumentation for in-pile experiments in Material Testing Reactor constitutes a main goal for the improvement of the nuclear fuel behavior knowledge. An acoustic method for fission gas release detection was tested with success during a first experiment called REMORA 3 in 2010 and 2011, and the results were used to differentiate helium and fission gas release kinetics under transient operating conditions. This experiment was lead at OSIRIS reactor (CEA Saclay, France). The maximal temperature on the sensor during the irradiation was about 150 deg. C. In this paper we present a thick film transducer produce by screen printing process. The screen printing of piezoelectric offers a wide range of possible applications for the development of acoustic sensors and piezoelectric structure for measurements in high temperature environment. We firstly produced a Lead Zirconate Titanate (PZT) based paste composed of Pz27 powder from Ferroperm, CF7575 glass, and organic solvent ESL 400. Likewise a Bismuth Titanate based paste synthesized in our laboratory was produced. With these inks we produced thick film up to 130 μm by screen printing process. Material properties characterizations of these thick-film resonators are essential for device design and applications. The piezoelectric coefficients d33 and pyro-electric P(T) coefficient are investigated. The highest P(T) and d33 are respectively 80 μC.m{sup -2}.K{sup -1} and 130 μC.N{sup -1} for the PZT transducer -which validates the fabrication process-. In view of the development of this transducer oriented for high temperature and irradiation environment, we investigated the electrical properties of the transducers for different ranges of frequencies and temperature - from 20 Hz up to 40 MHz between 30 and 400 deg. C. We highlight the evolution of the impedance response and piezoelectric parameters of screen printed piezoelectric structures on alumina. Shortly an irradiation will be realized in

  10. Acoustic measurements of a liquefied cohesive sediment bed under waves

    NASA Astrophysics Data System (ADS)

    Mosquera, R.; Groposo, V.; Pedocchi, F.

    2014-04-01

    In this article the response of a cohesive sediment deposit under the action of water waves is studied with the help of laboratory experiments and an analytical model. Under the same regular wave condition three different bed responses were observed depending on the degree of consolidation of the deposit: no bed motion, bed motion of the upper layer after the action of the first waves, and massive bed motion after several waves. The kinematic of the upper 3 cm of the deposit were measured with an ultrasound acoustic profiler, while the pore-water pressure inside the bed was simultaneously measured using several pore pressure sensors. A poro-elastic model was developed to interpret the experimental observations. The model showed that the amplitude of the shear stress increased down into the bed. Then it is possible that the lower layers of the deposit experience plastic deformations, while the upper layers present just elastic deformations. Since plastic deformations in the lower layers are necessary for pore pressure build-up, the analytical model was used to interpret the experimental results and to state that liquefaction of a self consolidated cohesive sediment bed would only occur if the bed yield stress falls within the range defined by the amplitude of the shear stress inside the bed.

  11. Evaluation of the Acoustic Measurement Capability of the NASA Langley V/STOL Wind Tunnel Open Test Section with Acoustically Absorbent Ceiling and Floor Treatments

    NASA Technical Reports Server (NTRS)

    Theobald, M. A.

    1978-01-01

    The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.

  12. Measurement of Plasma Clotting Using Shear Horizontal Surface Acoustic Wave Sensor

    NASA Astrophysics Data System (ADS)

    Nagayama, Tatsuya; Kondoh, Jun; Oonishi, Tomoko; Hosokawa, Kazuya

    2013-07-01

    The monitoring of blood coagulation is important during operation. In this study, a shear horizontal surface acoustic wave (SH-SAW) sensor is applied to monitor plasma clotting. An SH-SAW sensor with a metallized surface for mechanical perturbation detection can detect plasma clotting. As plasma clotting is a gel formation reaction, the SH-SAW sensor detects viscoelastic property changes. On the other hand, an SH-SAW sensor with a free surface for electrical perturbation detection detects only the liquid mixing effect. No electrical property changes due to plasma clotting are obtained using this sensor. A planar electrochemical sensor is also used to monitor plasma clotting. In impedance spectral analysis, plasma clotting is measured. However, in the measurement of time responses, no differences between clotting and nonclotting are obtained. Therefore, the SH-SAW sensor is useful for monitoring plasma clotting.

  13. Optimization of Acoustic Pressure Measurements for Impedance Eduction

    NASA Technical Reports Server (NTRS)

    Jones, M. G.; Watson, W. R.; Nark, D. M.

    2007-01-01

    As noise constraints become increasingly stringent, there is continued emphasis on the development of improved acoustic liner concepts to reduce the amount of fan noise radiated to communities surrounding airports. As a result, multiple analytical prediction tools and experimental rigs have been developed by industry and academia to support liner evaluation. NASA Langley has also placed considerable effort in this area over the last three decades. More recently, a finite element code (Q3D) based on a quasi-3D implementation of the convected Helmholtz equation has been combined with measured data acquired in the Langley Grazing Incidence Tube (GIT) to reduce liner impedance in the presence of grazing flow. A new Curved Duct Test Rig (CDTR) has also been developed to allow evaluation of liners in the presence of grazing flow and controlled, higher-order modes, with straight and curved waveguides. Upgraded versions of each of these two test rigs are expected to begin operation by early 2008. The Grazing Flow Impedance Tube (GFIT) will replace the GIT, and additional capabilities will be incorporated into the CDTR. The current investigation uses the Q3D finite element code to evaluate some of the key capabilities of these two test rigs. First, the Q3D code is used to evaluate the microphone distribution designed for the GFIT. Liners ranging in length from 51 to 610 mm are investigated to determine whether acceptable impedance eduction can be achieved with microphones placed on the wall opposite the liner. This analysis indicates the best results are achieved for liner lengths of at least 203 mm. Next, the effects of moving this GFIT microphone array to the wall adjacent to the liner are evaluated, and acceptable results are achieved if the microphones are placed off the centerline. Finally, the code is used to investigate potential microphone placements in the CDTR rigid wall adjacent to the wall containing an acoustic liner, to determine if sufficient fidelity can be

  14. Experimental study of coaxial nozzle exhaust noise. [acoustic measurements

    NASA Technical Reports Server (NTRS)

    Goodykoontz, J. H.; Stone, J. R.

    1979-01-01

    Experimental results are presented for static acoustic model tests of various geometrical configurations of coaxial nozzles operating over a range of flow conditions. The geometrical configurations consisted of nozzles with coplanar and non-coplanar exit planes and various exhaust area ratios. Primary and secondary nozzle flows were varied independently over a range of nozzle pressure ratios from 1.4 to 3.0 and gas temperatures from 280 to 1100 K. Acoustic data are presented for the conventional mode of coaxial nozzle operation as well as for the inverted velocity profile mode. Comparisons are presented to show the effect of configuration and flow changes on the acoustic characteristics of the nozzles.

  15. The Belt voice: Acoustical measurements and esthetic correlates

    NASA Astrophysics Data System (ADS)

    Bounous, Barry Urban

    This dissertation explores the esthetic attributes of the Belt voice through spectral acoustical analysis. The process of understanding the nature and safe practice of Belt is just beginning, whereas the understanding of classical singing is well established. The unique nature of the Belt sound provides difficulties for voice teachers attempting to evaluate the quality and appropriateness of a particular sound or performance. This study attempts to provide answers to the question "does Belt conform to a set of measurable esthetic standards?" In answering this question, this paper expands on a previous study of the esthetic attributes of the classical baritone voice (see "Vocal Beauty", NATS Journal 51,1) which also drew some tentative conclusions about the Belt voice but which had an inadequate sample pool of subjects from which to draw. Further, this study demonstrates that it is possible to scientifically investigate the realm of musical esthetics in the singing voice. It is possible to go beyond the "a trained voice compared to an untrained voice" paradigm when evaluating quantitative vocal parameters and actually investigate what truly beautiful voices do. There are functions of sound energy (measured in dB) transference which may affect the nervous system in predictable ways and which can be measured and associated with esthetics. This study does not show consistency in measurements for absolute beauty (taste) even among belt teachers and researchers but does show some markers with varying degrees of importance which may point to a difference between our cognitive learned response to singing and our emotional, more visceral response to sounds. The markers which are significant in determining vocal beauty are: (1) Vibrancy-Characteristics of vibrato including speed, width, and consistency (low variability). (2) Spectral makeup-Ratio of partial strength above the fundamental to the fundamental. (3) Activity of the voice-The quantity of energy being produced. (4

  16. Dummy head microphone and its application to the measurements of electro-acoustic equipments

    NASA Astrophysics Data System (ADS)

    1984-12-01

    An acoustic measurement system using a dummy head microphone was developed. The system consists of a dummy head microphone and an equipment for digital signal processing, and the system can be used to measure characteristics of hearing aids and headphones. The ear simulator, newly developed for practical use, is terminated in a simple resistance element of 320 cgs acoustic ohms. The dummy head microphone with the ear simulator shows the good agreement with the acoustical characteristics of the averaged human external ear. Several measured results of hearing aids and headphones using the measurement system are shown.

  17. Acoustic measurements of F-15 aircraft operating in hush house, NSN 4920-02-070-2721

    NASA Astrophysics Data System (ADS)

    Miller, V. R.; Plzak, G. A.; Chinn, J. M.

    1981-09-01

    The purpose of this test program was to measure the acoustic environment in the hush house facility located at Kelly Air Force Base, Texas, during operation of the F-15 aircraft to ensure that aircraft structural acoustic design limits were not exceeded. The acoustic measurements showed that no potential sonic fatigue problems are anticipated with the F-15 aircraft structure during operation in the hush house. However, since these acoustic levels were increased over those measuring during run up on a concrete pad, it is recommended that F-15 equipment qualification levels be checked. The data indicated that the noise field within the hush house is diffuse and that the acoustical energy in the hangar area is radiated from the region between the engine exhaust and the hush house muffler front edge toward the forward part of the hangar.

  18. Exploring the feasibility of smart phone microphone for measurement of acoustic voice parameters and voice pathology screening.

    PubMed

    Uloza, Virgilijus; Padervinskis, Evaldas; Vegiene, Aurelija; Pribuisiene, Ruta; Saferis, Viktoras; Vaiciukynas, Evaldas; Gelzinis, Adas; Verikas, Antanas

    2015-11-01

    The objective of this study is to evaluate the reliability of acoustic voice parameters obtained using smart phone (SP) microphones and investigate the utility of use of SP voice recordings for voice screening. Voice samples of sustained vowel/a/obtained from 118 subjects (34 normal and 84 pathological voices) were recorded simultaneously through two microphones: oral AKG Perception 220 microphone and SP Samsung Galaxy Note3 microphone. Acoustic voice signal data were measured for fundamental frequency, jitter and shimmer, normalized noise energy (NNE), signal to noise ratio and harmonic to noise ratio using Dr. Speech software. Discriminant analysis-based Correct Classification Rate (CCR) and Random Forest Classifier (RFC) based Equal Error Rate (EER) were used to evaluate the feasibility of acoustic voice parameters classifying normal and pathological voice classes. Lithuanian version of Glottal Function Index (LT_GFI) questionnaire was utilized for self-assessment of the severity of voice disorder. The correlations of acoustic voice parameters obtained with two types of microphones were statistically significant and strong (r = 0.73-1.0) for the entire measurements. When classifying into normal/pathological voice classes, the Oral-NNE revealed the CCR of 73.7% and the pair of SP-NNE and SP-shimmer parameters revealed CCR of 79.5%. However, fusion of the results obtained from SP voice recordings and GFI data provided the CCR of 84.60% and RFC revealed the EER of 7.9%, respectively. In conclusion, measurements of acoustic voice parameters using SP microphone were shown to be reliable in clinical settings demonstrating high CCR and low EER when distinguishing normal and pathological voice classes, and validated the suitability of the SP microphone signal for the task of automatic voice analysis and screening.

  19. Effects of Various Architectural Parameters on Six Room Acoustical Measures in Auditoria.

    NASA Astrophysics Data System (ADS)

    Chiang, Wei-Hwa

    The effects of architectural parameters on six room acoustical measures were investigated by means of correlation analyses, factor analyses and multiple regression analyses based on data taken in twenty halls. Architectural parameters were used to estimate acoustical measures taken at individual locations within each room as well as the averages and standard deviations of all measured values in the rooms. The six acoustical measures were Early Decay Time (EDT10), Clarity Index (C80), Overall Level (G), Bass Ratio based on Early Decay Time (BR(EDT)), Treble Ratio based on Early Decay Time (TR(EDT)), and Early Inter-aural Cross Correlation (IACC80). A comprehensive method of quantifying various architectural characteristics of rooms was developed to define a large number of architectural parameters that were hypothesized to effect the acoustical measurements made in the rooms. This study quantitatively confirmed many of the principles used in the design of concert halls and auditoria. Three groups of room architectural parameters such as the parameters associated with the depth of diffusing surfaces were significantly correlated with the hall standard deviations of most of the acoustical measures. Significant differences of statistical relations among architectural parameters and receiver specific acoustical measures were found between a group of music halls and a group of lecture halls. For example, architectural parameters such as the relative distance from the receiver to the overhead ceiling increased the percentage of the variance of acoustical measures that was explained by Barron's revised theory from approximately 70% to 80% only when data were taken in the group of music halls. This study revealed the major architectural parameters which have strong relations with individual acoustical measures forming the basis for a more quantitative method for advancing the theoretical design of concert halls and other auditoria. The results of this study provide

  20. Acoustic Measurements in a Hexamethyldisiloxane-Loaded Low-Temperature Direct Barrier Discharge (DBD) Plasma Effluent: Nozzle Cleaning

    NASA Astrophysics Data System (ADS)

    Burkert, A.; Müller, D.; Paa, W.

    2015-04-01

    Acoustic emission (AE) measurements as well as laser light scattering experiments were performed during SiO2 layer deposition. SiO2 was generated in low-temperature atmospheric plasma torches (≤500 W), which were seeded with hexamethyldisiloxane. These AE measurements can be used to detect the necessity for nozzle cleaning online. The plasma torches were used to obtain high-quality SiO2 coatings. For electrical power of less than 350 W, we observed parasitic SiO2 deposition in the burner nozzle, which decreases the nozzle aperture within several hours of operation time. No parasitic SiO2 deposition inside the burner nozzle was observed when the plasma source was operated at more than 350 W. The reduced nozzle aperture causes increased plasma velocities and acoustic noise. Especially burst-like increases of this acoustic emission were assumed to be correlated to the ejection of particles. This hypothesis could be confirmed by measurements of scattered light from a sheet of laser light at 248 nm. The obtained correlations suggest using a microphone as a low-cost monitor for the degree of parasitic deposition inside the plasma burner nozzle. The threshold for acoustic noise detection has to be chosen low enough to avoid burst-like emission of particles.

  1. On measuring the absolute scale of baryon acoustic oscillations

    NASA Astrophysics Data System (ADS)

    Sutherland, Will

    2012-10-01

    The baryon acoustic oscillation (BAO) feature in the distribution of galaxies provides a fundamental standard ruler which is widely used to constrain cosmological parameters. In most analyses, the comoving length of the ruler is inferred from a combination of cosmic microwave background (CMB) observations and theory. However, this inferred length may be biased by various non-standard effects in early universe physics; this can lead to biased inferences of cosmological parameters such as H0, Ωm and w, so it would be valuable to measure the absolute BAO length by combining a galaxy redshift survey and a suitable direct low-z distance measurement. One obstacle is that low-redshift BAO surveys mainly constrain the ratio rS/DV(z), where DV is a dilation scale which is not directly observable by standard candles. Here, we find a new approximation DV(z)≃34DL(43z)(1+43z)-1(1-0.02455 z3+0.0105 z4) which connects DV to the standard luminosity distance DL at a somewhat higher redshift; this is shown to be very accurate (relative error <0.2 per cent) for all Wilkinson Microwave Anisotropy Probe compatible Friedmann models at z < 0.4, with very weak dependence on cosmological parameters H0, Ωm, Ωk, w. This provides a route to measure the absolute BAO length using only observations at z ≲ 0.3, including Type Ia supernovae, and potentially future H0-free physical distance indicators such as gravitational lenses or gravitational wave standard sirens. This would provide a zero-parameter check of the standard cosmology at 103 ≲ z ≲ 105, and can constrain the number of relativistic species Neff with fewer degeneracies than the CMB.

  2. Direct opto-acoustic in vitro measurement of the spatial distribution of laser radiation in biological media

    SciTech Connect

    Pelivanov, Ivan M; Belov, Sergej A; Solomatin, Vladimir S; Khokhlova, Tanya D; Karabutov, Aleksander A

    2006-12-31

    The problem of opto-acoustic (AO) diagnostics of light scattering and absorption in biological media is considered. The objects under study were milk, bovine and porcine liver, and bovine muscle tissue. The forward and backward schemes for recording acoustic signals were used in experiments. The spatial distribution of the light intensity was measured for each biological medium from the temporal profile of the excited OA pulse and the absorption coefficient and reduced scattering coefficient were determined. Opto-acoustic signals were excited by a 1064-nm pulsed Nd:YAG laser and a tunable Ti:sapphire laser at 779 nm. It is shown that the proposed method can be used for obtaining a priori information on a biological medium in problems of optical and AO tomography. (special issue devoted to multiple radiation scattering in random media)

  3. Influence of Architectural Features and Styles on Various Acoustical Measures in Churches

    NASA Astrophysics Data System (ADS)

    Carvalho, Antonio Pedro Oliveira De.

    This work reports on acoustical field measurements made in a major survey of 41 Catholic churches in Portugal that were built in the last 14 centuries. A series of monaural and binaural acoustical measurements was taken at multiple source/receiver positions in each church using the impulse response with noise burst method. The acoustical measures were Reverberation Time (RT), Early Decay Time (EDT), Clarity (C80), Definition (D), Center Time (TS), Loudness (L), Bass Ratios based on the Reverberation Time and Loudness rm (BR_-RT and rm BR_-L), Rapid Speech Transmission Index (RASTI), and the binaural Coherence (COH). The scope of this research is to investigate how the acoustical performance of Catholic churches relates to their architectural features and to determine simple formulas to predict acoustical measures by the use of elementary architectural parameters. Prediction equations were defined among the acoustical measures to estimate values at individual locations within each room as well as the mean values in each church. Best fits with rm R^2~0.9 were not uncommon among many of the measures. Within and interchurch differences in the data for the acoustical measures were also analyzed. The variations of RT and EDT were identified as much smaller than the variations of the other measures. The churches tested were grouped in eight architectural styles, and the effect of their evolution through time on these acoustical measures was investigated. Statistically significant differences were found regarding some architectural styles that can be traced to historical changes in Church history, especially to the Reformation period. Prediction equations were defined to estimate mean acoustical measures by the use of fifteen simple architectural parameters. The use of the Sabine and Eyring reverberation time equations was tested. The effect of coupled spaces was analyzed, and a new algorithm for the application of the Sabine equation was developed, achieving an average of

  4. Properties of Noise Cross Correlation Functions Obtained from a Distributed Acoustic Sensing (DAS) Array at Garner Valley, California

    NASA Astrophysics Data System (ADS)

    Zeng, X.; Lancelle, C.; Thurber, C. H.; Fratta, D.; Wang, H. F.; Chalari, A.; Clarke, A.

    2015-12-01

    The field test of Distributed Acoustic Sensing (DAS) conducted at Garner Valley, California on September 11-12, 2013 provided a continuous overnight record of ambient noise. The DAS array recorded ground motions every one meter of optical cable that was arranged approximately in the shape of a rectangle with dimensions of 160 m by 80 m. The long dimension of the array was adjacent to a state highway. Three hours of record were used to compute noise cross-correlation functions (NCFs) in one-minute windows. The trace from each sensor channel was pre-processed by downsampling to 200 Hz, followed by normalization in the time-domain and bandpass filtering between 2 and 20 Hz (Bensen et al., 2007). The one-minute NCFs were then stacked using the time-frequency domain phase-weighted stacking method (Schimmel & Gallart, 2007). The NCFs between channels were asymmetrical reflecting the direction of traffic noise. The group velocities were found using the frequency-time analysis method. The energy was concentrated between 5 and 15 Hz, which falls into the typical traffic noise frequency band. The resulting velocities were between 100 and 300 m/s for frequencies between 10 and 20 Hz, which are in the same range as described in the results for surface-wave dispersion obtained using an active source for the same site (Lancelle et al., 2015). The group velocity starts to decrease for frequencies greater than ~10 Hz, which was expected on the basis of a previous shear-wave velocity model (Steidl et al., 1996). Then, the phase velocity was calculated using the multichannel analysis of surface wave technique (MASW - Park et al., 1999) with 114 NCFs spaced one meter apart. The resulting dispersion curve between 5 and 15 Hz gave phase velocities that ranged from approximately 170 m/s at 15 Hz to 250 m/s at 5 Hz. These results are consistent with other results of active-source DAS and seismometer records obtained at the Garner Valley site (e.g., Stokoe et al. 2004). This analysis is

  5. In situ measurement of the reinforcement modulus in a metal matrix composite by acoustic microscopy

    SciTech Connect

    Canumalla, S.; Gordon, G.A.; Pangborn, R.N.

    1995-12-31

    The mechanical properties of metal-matrix composites have been observed to be a strong function of the content of non-fiber inclusions. Shot particles, with the nominal composition of the reinforcement, have been found to crack prematurely, thus representing prefer-red failure initiation sites under mechanical and thermal fatigue of discontinuous, alumina-silicate fiber reinforced aluminum matrix composites. To better understand the differences between the responses of the shot and fibers to loading, the Young`s modulus of the shot is measured and compared to that of the fibers. Scanning acoustic microscopy is used to nondestructively measure the modulus of the shot in situ, and the fiber modulus is obtained from the previously measured composite response. The shot, with a modulus of 131.5 GPa, has a Young`s modulus that is approximately 40% lower than that of the fibers. The influence of this on the composite response will be discussed.

  6. Relative measurement of acoustic nonlinear parameters and comparison of sensitivity to thermal aging

    NASA Astrophysics Data System (ADS)

    Seo, Hogeon; Ren, Gang; Kim, Jongbeom; Jhang, Kyung-Young

    2015-03-01

    The acoustic nonlinearity measurement of ultrasonic waves are being extensively researched as a promising nondestructive evaluation element. In the condition of constant propagation distance and wave number, many researchers have measured the second-order relative acoustic nonlinear parameter, β', that can be simply defined as the ratio of the amplitude of the second harmonic frequency component to the amplitude squared of the fundamental frequency component and compared them in order to identify the acoustic nonlinearity variation according to material degradation. In this study, we extended this concept to the third-order relative acoustic nonlinear parameter, γ', by defining it as the ratio of the amplitude of the third harmonic frequency component to the amplitude cubed of the fundamental frequency component. To investigate its effectiveness as a nondestructive evaluation element for the material property degradation, both the second-order acoustic relative nonlinear parameter and the third-order relative acoustic nonlinear parameter were measured for the aluminum specimens processed by heat treatment for the different times and then contrasted each other. From the experimental results, the third-order acoustic relative nonlinear parameter was more sensitive than the second-order relative acoustic nonlinear parameter that has been widely used although the amplitude of the third harmonic frequency component was lower than the amplitude of the second harmonic frequency component.

  7. Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force.

    PubMed

    Shou, Wende; Huang, Xiaowei; Duan, Shimei; Xia, Rongmin; Shi, Zhonglong; Geng, Xiaoming; Li, Faqi

    2006-12-22

    How to measure the acoustic power of HIFU is one of the most important tasks in its medical application. In the paper a whole series of formula for calculating the radiation force related to the acoustic power radiated by a single element focusing transducer and by the focusing transducer array were given. Various system of radiation force balance (RFB) to measure the acoustic power of HIFU in medicine were designed and applied in China. In high power experiments, the dependence of radiation force acting the absorbing target on the target position at the beam axis of focusing transducer was fined. There is a peak value of "radiation force" acting the absorbing target in the focal region when the acoustic power through the focal plane exceeds some threshold. In order to avoid this big measurement error caused by the 'peak effect' in focal region, the distance between the absorbing target of RFB and the focusing transducer or transducer array was defined to be equal to or less than 0.7 times of the focal length in the National Standard of China for the measurements of acoustic power and field characteristics of HIFU. More than six different therapeutic equipments of HIFU have been examined by RFB for measuring the acoustic power since 1998. These results show that RFB with the absorbing target is valid in the acoustic power range up to 500W with good linearity for the drive voltage squared of focusing transducer or array. The uncertainty of measurement is within +/-15%.

  8. Calibration of an acoustic system for measuring 2-D temperature distribution around hydrothermal vents.

    PubMed

    Fan, Wei; Chen, Chen-Tung Arthur; Chen, Ying

    2013-04-01

    One of the fundamental purposes of quantitative acoustic surveys of seafloor hydrothermal vents is to measure their 2-D temperature distributions. Knowing the system latencies and the acoustic center-to-center distances between the underwater transducers in an acoustic tomography system is fundamental to the overall accuracy of the temperature reconstruction. However, commercial transducer sources typically do not supply the needed data. Here we present a novel calibration algorithm to automatically determine the system latencies and the acoustic center-to-center distances. The possible system latency error and the resulting temperature error are derived and analyzed. We have also developed the experimental setup for calibration. To validate the effectiveness of the proposed calibration method, an experimental study was performed on acoustic imaging of underwater temperature fields in Lake Qiezishan, located at Longling County, Yunnan Province, China. Using the calibrated data, the reconstructed temperature distributions closely resemble the actual distributions measured with thermocouples, thus confirming the effectiveness of our algorithm.

  9. Vector network analyzer measurement of the amplitude of an electrically excited surface acoustic wave and validation by X-ray diffraction

    NASA Astrophysics Data System (ADS)

    Camara, I. S.; Croset, B.; Largeau, L.; Rovillain, P.; Thevenard, L.; Duquesne, J.-Y.

    2017-01-01

    Surface acoustic waves are used in magnetism to initiate magnetization switching, in microfluidics to control fluids and particles in lab-on-a-chip devices, and in quantum systems like two-dimensional electron gases, quantum dots, photonic cavities, and single carrier transport systems. For all these applications, an easy tool is highly needed to measure precisely the acoustic wave amplitude in order to understand the underlying physics and/or to optimize the device used to generate the acoustic waves. We present here a method to determine experimentally the amplitude of surface acoustic waves propagating on Gallium Arsenide generated by an interdigitated transducer. It relies on Vector Network Analyzer measurements of S parameters and modeling using the Coupling-Of-Modes theory. The displacements obtained are in excellent agreement with those measured by a very different method based on X-ray diffraction measurements.

  10. Local oscillator phase noise limitation on the resolution of acoustic delay line wireless passive sensor measurement

    NASA Astrophysics Data System (ADS)

    Chrétien, N.; Friedt, J.-M.; Martin, G.

    2014-06-01

    The role of the phase noise of a local oscillator driving a pulsed-mode RADAR used for probing surface acoustic wave sensors is investigated. The echo delay, representative of the acoustic velocity, and hence the physical quantity probed by the sensor, is finely measured as a phase. Considering that the intrinsic oscillator phase fluctuation defines the phase noise measurement resolution, we experimentally and theoretically assess the relation between phase noise, measurement range, and measurand resolution.

  11. Measuring Turbulence from Moored Acoustic Doppler Velocimeters. A Manual to Quantifying Inflow at Tidal Energy Sites

    SciTech Connect

    Kilcher, Levi; Thomson, Jim; Talbert, Joe; DeKlerk, Alex

    2016-03-01

    This work details a methodology for measuring hub height inflow turbulence using moored acoustic Doppler velocimiters (ADVs). This approach is motivated by the shortcomings of alternatives. For example, remote velocity measurements (i.e., from acoustic Doppler profilers) lack sufficient precision for device simulation, and rigid tower-mounted measurements are very expensive and technically challenging in the tidal environment. Moorings offer a low-cost, site-adaptable and robust deployment platform, and ADVs provide the necessary precision to accurately quantify turbulence.

  12. Acoustic measurement of sediment dynamics in the coastal zones using wireless sensor networks

    NASA Astrophysics Data System (ADS)

    Sudhakaran, A., II; Paramasivam, A.; Seshachalam, S.; A, C.

    2014-12-01

    Analyzing of the impact of constructive or low energy waves and deconstructive or high energy waves in the ocean are very much significant since they deform the geometry of seashore. The deformation may lead to productive result and also to the end of deteriorate damage. Constructive waves results deposition of sediment which widens the beach where as deconstructive waves results erosion which narrows the beach. Validation of historic sediment transportation and prediction of the direction of movement of seashore is essential to prevent unrecoverable damages by incorporating precautionary measurements to identify the factors that influence sediment transportation if feasible. The objective of this study is to propose a more reliable and energy efficient Information and communication system to model the Coastal Sediment Dynamics. Various factors influencing the sediment drift at a particular region is identified. Consequence of source depth and frequency dependencies of spread pattern in the presence of sediments is modeled. Property of source depth and frequency on sensitivity to values of model parameters are determined. Fundamental physical reasons for these sediment interaction effects are given. Shallow to deep water and internal and external wave model of ocean is obtained intended to get acoustic data assimilation (ADA). Signal processing algorithms are used over the observed data to form a full field acoustic propagation model and construct sound speed profile (SSP). The inversions of data due to uncertainties at various depths are compared. The impact of sediment drift over acoustic data is identified. An energy efficient multipath routing scheme Wireless sensor networks (WSN) is deployed for the well-organized communication of data. The WSN is designed considering increased life time, decreased power consumption, free of threats and attacks. The practical data obtained from the efficient system to model the ocean sediment dynamics are evaluated with remote

  13. Preliminary Analysis of Acoustic Measurements from the NASA-Gulfstream Airframe Noise Flight Test

    NASA Technical Reports Server (NTRS)

    Khorrami, Mehdi R.; Lockhard, David D.; Humphreys, Willliam M.; Choudhari, Meelan M.; Van De Ven, Thomas

    2008-01-01

    The NASA-Gulfstream joint Airframe Noise Flight Test program was conducted at the NASA Wallops Flight Facility during October, 2006. The primary objective of the AFN flight test was to acquire baseline airframe noise data on a regional jet class of transport in order to determine noise source strengths and distributions for model validation. To accomplish this task, two measuring systems were used: a ground-based microphone array and individual microphones. Acoustic data for a Gulfstream G550 aircraft were acquired over the course of ten days. Over twenty-four test conditions were flown. The test matrix was designed to provide an acoustic characterization of both the full aircraft and individual airframe components and included cruise to landing configurations. Noise sources were isolated by selectively deploying individual components (flaps, main landing gear, nose gear, spoilers, etc.) and altering the airspeed, glide path, and engine settings. The AFN flight test program confirmed that the airframe is a major contributor to the noise from regional jets during landing operations. Sound pressure levels from the individual microphones on the ground revealed the flap system to be the dominant airframe noise source for the G550 aircraft. The corresponding array beamform maps showed that most of the radiated sound from the flaps originates from the side edges. Using velocity to the sixth power and Strouhal scaling of the sound pressure spectra obtained at different speeds failed to collapse the data into a single spectrum. The best data collapse was obtained when the frequencies were left unscaled.

  14. Measuring the distance-redshift relation with the baryon acoustic oscillations of galaxy clusters

    NASA Astrophysics Data System (ADS)

    Veropalumbo, A.; Marulli, F.; Moscardini, L.; Moresco, M.; Cimatti, A.

    2016-05-01

    We analyse the largest spectroscopic samples of galaxy clusters to date, and provide observational constraints on the distance-redshift relation from baryon acoustic oscillations. The cluster samples considered in this work have been extracted from the Sloan Digital Sky Survey at three median redshifts, z = 0.2, 0.3 and 0.5. The number of objects is 12 910, 42 215 and 11 816, respectively. We detect the peak of baryon acoustic oscillations for all the three samples. The derived distance constraints are rs/DV(z = 0.2) = 0.18 ± 0.01, rs/DV(z = 0.3) = 0.124 ± 0.004 and rs/DV(z = 0.5) = 0.080 ± 0.002. Combining these measurements with the sound horizon scale measured from the cosmic microwave background, we obtain robust constraints on cosmological parameters. Our results are in agreement with the standard Λ cold dark matter (ΛCDM) model. Specifically, we constrain the Hubble constant in a ΛCDM model, H_0 = 64_{-8}^{+17} km s^{-1} Mpc^{-1} , the density of curvature energy, in the oΛCDM context, Ω _K = -0.01_{-0.33}^{+0.34}, and finally the parameter of the dark energy equation of state in the wCDM case, w = -1.06_{-0.52}^{+0.49}. This is the first time the distance-redshift relation has been constrained using only the peak of baryon acoustic oscillations of galaxy clusters.

  15. A Study of Acoustic Reflections in Full-Scale Rotor Low Frequency Noise Measurements Acquired in Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Barbely, Natasha L.; Sim, Ben W.; Kitaplioglu, Cahit; Goulding, Pat, II

    2010-01-01

    Difficulties in obtaining full-scale rotor low frequency noise measurements in wind tunnels are addressed via residual sound reflections due to non-ideal anechoic wall treatments. Examples illustrated with the Boeing-SMART rotor test in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel facility demonstrated that these reflections introduced distortions in the measured acoustic time histories that are not representative of free-field rotor noise radiation. A simplified reflection analysis, based on the method of images, is used to examine the sound measurement quality in such "less-than-anechoic" environment. Predictions of reflection-adjusted acoustic time histories are qualitatively shown to account for some of the spurious fluctuations observed in wind tunnel noise measurements

  16. Measuring baryon acoustic oscillations from the clustering of voids

    NASA Astrophysics Data System (ADS)

    Liang, Yu; Zhao, Cheng; Chuang, Chia-Hsun; Kitaura, Francisco-Shu; Tao, Charling

    2016-07-01

    We investigate the necessary methodology to optimally measure the baryon acoustic oscillation (BAO) signal from voids, based on galaxy redshift catalogues. To this end, we study the dependence of the BAO signal on the population of voids classified by their sizes. We find for the first time the characteristic features of the correlation function of voids including the first robust detection of BAOs in mock galaxy catalogues. These show an anti-correlation around the scale corresponding to the smallest size of voids in the sample (the void exclusion effect), and dips at both sides of the BAO peak, which can be used to determine the significance of the BAO signal without any priori model. Furthermore, our analysis demonstrates that there is a scale-dependent bias for different populations of voids depending on the radius, with the peculiar property that the void population with the largest BAO significance corresponds to tracers with approximately zero bias on the largest scales. We further investigate the methodology on an additional set of 1000 realistic mock galaxy catalogues reproducing the SDSS-III/BOSS CMASS DR11 data, to control the impact of sky mask and radial selection function. Our solution is based on generating voids from randoms including the same survey geometry and completeness, and a post-processing cleaning procedure in the holes and at the boundaries of the survey. The methodology and optimal selection of void populations validated in this work have been used to perform the first BAO detection from voids in observations, presented in a companion paper.

  17. Acoustic and manual measurements of methane ebullition in peatlands

    NASA Astrophysics Data System (ADS)

    Varner, R. K.; Palace, M. W.; Lennartz, J. M.; Wik, M.; Crill, P. M.; Ewing, S. A.; Harden, J. W.; Turetsky, M. R.

    2013-12-01

    Controls on the magnitude and frequency of methane (CH4) release through ebullition (bubbling) in water saturated ecosystems such as bogs, fens and lakes are important to both the atmospheric and ecosystems science community. In order to understand the response of these ecosystems to future climate forcing, we need to systematically monitor ebullition from these ecosystems over many seasons and across a multitude of landscape morphologies. We have developed and field tested an inexpensive array of sampling/monitoring instruments to identify the frequency and magnitude of bubbling events which allows us to correlate bubble data with potential drivers such as changes in hydrostatic pressure, wind and temperature. The instrument consists of a nested, inverted funnel design with a hydrophone for detecting bubbles that rise through the peat. The design offers a way to sample the gas collected in the funnels to determine the concentration of CH4. Laboratory calibration of the instrument resulted in an equation that relates frequency of bubbles hitting the hydrophone with bubble volume. Audio data was recorded continuously using a digital audio recorder attached to two ebullition sensors and could be deployed remotely for up to 20 days. Time, fundamental frequency, and estimated bubble size were determined using MATLAB code. Manual bubble flux measurements were also made for comparison to the acoustically sensed ebullition. Instruments were deployed in summers 2011-2013 at a temperate fen (Sallie's Fen, NH, USA) and a subarctic mire (Stordalen, Abisko, Sweden). We also recorded ebullition at two locations in subarctic Alaska (APEX Research Site, Fairbanks, AK and Innoko National Wildlife Refuge) during summer 2011. Ebullition was observed at all sites with highest daily rates in fen versus bog sites. Observed distributions of bubble events correlate with published models of ebullition based on peat density.

  18. Imaging and detection of mines from acoustic measurements

    NASA Astrophysics Data System (ADS)

    Witten, Alan J.; DiMarzio, Charles A.; Li, Wen; McKnight, Stephen W.

    1999-08-01

    A laboratory-scale acoustic experiment is described where a buried target, a hockey puck cut in half, is shallowly buried in a sand box. To avoid the need for source and receiver coupling to the host sand, an acoustic wave is generated in the subsurface by a pulsed laser suspended above the air-sand interface. Similarly, an airborne microphone is suspended above this interface and moved in unison with the laser. After some pre-processing of the data, reflections for the target, although weak, could clearly be identified. While the existence and location of the target can be determined by inspection of the data, its unique shape can not. Since target discrimination is important in mine detection, a 3D imaging algorithm was applied to the acquired acoustic data. This algorithm yielded a reconstructed image where the shape of the target was resolved.

  19. Characterization of Transducer Performance and Narrowband Transient Ultrasonic Fields in Metals by Rayleigh-Sommerfeld Backpropagation of Compression Acoustic Waves Measured with Double-Pulsed Tv Holography

    NASA Astrophysics Data System (ADS)

    Trillo, Cristina; Doval, Ángel F.; Fernández, José L.; Rodríguez-Gómez, Pablo; López-Vázquez, J. Carlos

    2014-10-01

    This article presents a method aimed at the characterization of the narrowband transient acoustic field radiated by an ultrasonic plane transducer into a homogeneous, isotropic and optically opaque prismatic solid, and the assessment of the performance of the acoustic source. The method relies on a previous technique based on the full-field optical measurement of an acoustic wavepacket at the surface of a solid and its subsequent numerical backpropagation within the material. The experimental results show that quantitative transversal and axial profiles of the complex amplitude of the beam can be obtained at any plane between the measurement and excitation surfaces. The reconstruction of the acoustic field at the transducer face, carried out on a defective transducer model, shows that the method could also be suitable for the nondestructive testing of the performance of ultrasonic sources. In all cases, the measurements were performed with the transducer working under realistic loading conditions.

  20. Acoustic Measurement and Model Predictions for the Aural Nondetectability of Two Night-Vision Goggles

    DTIC Science & Technology

    2013-11-01

    Acoustic Measurement and Model Predictions for the Aural Nondetectability of Two Night - Vision Goggles by Jeremy Gaston, Tim Mermagen, and...SUBTITLE Acoustic Measurement and Model Predictions for the Aural Nondetectability of Two Night - Vision Goggles 5a. CONTRACT NUMBER 5b. GRANT NUMBER...13. SUPPLEMENTARY NOTES 14. ABSTRACT This study evaluates two different night - vision goggles (NVGs) to determine if the devices meet level II

  1. Underwater hybrid near-field acoustical holography based on the measurement of vector hydrophone array

    NASA Astrophysics Data System (ADS)

    Hu, Bo; Yang, Desen; Sun, Yu

    2010-06-01

    Hybrid near-field acoustical holography (NAH) is developed for reconstructing acoustic radiation from a cylindrical source in a complex underwater environment. In hybrid NAH, we combine statistically optimized near-field acoustical holography (SONAH) and broadband acoustical holography from intensity measurements (BAHIM) to reconstruct the underwater cylindrical source field. First, the BAHIM is utilized to regenerate as much acoustic pressures on the hologram surface as necessary, and then the acoustic pressures are taken as input to the formulation implemented numerically by SONAH. The main advantages of this technology are that the complex pressure on the hologram surface can be reconstructed without reference signal, and the measurement array can be smaller than the source, thus the practicability and efficiency of this technology are greatly enhanced. Numerical examples of a cylindrical source are demonstrated. Test results show that hybrid NAH can yield a more accurate reconstruction than conventional NAH. Then, an experiment has been carried out with a vector hydrophone array. The experimental results show the advantage of hybrid NAH in the reconstruction of an acoustic field and the feasibility of using a vector hydrophone array in an underwater NAH measurement, as well as the identification and localization of noise sources.

  2. Acoustic backscattering by deepwater fish measured in situ from a manned submersible

    NASA Astrophysics Data System (ADS)

    Benoit-Bird, Kelly J.; Au, Whitlow W. L.; Kelley, Christopher D.; Taylor, Christopher

    2003-02-01

    An outstanding problem in fisheries acoustics is the depth dependence of scattering characteristics of swimbladder-bearing fish, and the effects of pressure on the target strength of physoclistous fish remain unresolved. In situ echoes from deepwater snappers were obtained with a sonar transducer mounted on a manned submersible next to a low-light video camera, permitting simultaneous echo recording and identification of species, fish size and orientation. The sonar system, consisting of a transducer, single board computer, hard disk, and analog-to-digital converter, used a 80 μs, broadband signal (bandwidth 35 kHz, center frequency 120 kHz). The observed relationship between fish length and in situ target strength shows no difference from the relationship measured at the surface. No differences in the species-specific temporal echo characteristics were observed between surface and in situ measures. This indicates that the size and shape of the snappers' swimbladders are maintained both at the surface and at depths of up to 250 m. Information obtained through controlled backscatter measurements of tethered, anesthetized fish at the surface can be applied to free-swimming fish at depth. This is the first published account of the use of a manned submersible to measure in situ scattering from identified, individual animals with known orientations. The distinct advantage of this technique compared with other in situ techniques is the ability to observe the target fish, obtaining accurate species, size, and orientation information.

  3. Fish Acoustics: Physics-Based Modeling and Measurement

    DTIC Science & Technology

    2011-01-01

    physical scattering mechanisms. To demonstrate this point, the target strength of a canonical gas-filled sphere is computed using a standard...high-frequency sound scattering by swimbladdered fish,” Journal of the Acoustical Society of America, Vol. 78, pp. 688-700 (1985). 9. Gauss , R. C

  4. Instrumental Dimensioning of Normal and Pathological Phonation Using Acoustic Measurements

    ERIC Educational Resources Information Center

    Putzer, Manfred; Barry, William J.

    2008-01-01

    The present study deals with the dimensions of normal and pathological phonation. Separation of normal voices from pathological voices is tested under different aspects. Using a new parametrization of voice-quality properties in the acoustic signal, the vowel productions of 534 speakers (267 M, 267 F) without any reported voice pathology and the…

  5. Acoustic measurements of soil-pipeflow and internal erosion

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Internal erosion of soil pipes can lead to embankment failures, landslides, and gully erosion. Therefore, non-intrusive methods are needed to detect and monitor soil pipeflow and the resulting internal erosion. This paper presents a laboratory study using both active and passive acoustic techniques ...

  6. Acoustic measurements of soil pipeflow and internal erosion

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Internal erosion of soil pipes can lead to embankment failures, landslides, and gully erosion therefore non-intrusive methods are needed to detect and monitor soil pipeflow and the resulting internal erosion. This paper presents a laboratory study using both active and passive acoustic techniques to...

  7. DIASCoPE: Directly integrated acoustic system combined with pressure experiments—A new method for fast acoustic velocity measurements at high pressure

    NASA Astrophysics Data System (ADS)

    Whitaker, Matthew L.; Baldwin, Kenneth J.; Huebsch, William R.

    2017-03-01

    A new experimental system to measure elastic wave velocities in samples in situ under extreme conditions of pressure and temperature in a multi-anvil apparatus has been installed at Beamline 6-BM-B of the Advanced Photon Source at Argonne National Laboratory. This system allows for measurement of acoustic velocities via ultrasonic interferometry, and makes use of the synchrotron beam to measure sample densities via X-ray diffraction and sample lengths using X-radiographic imaging. This system is fully integrated into the automated software controls of the beamline and is capable of collecting robust data on elastic wave travel times in less than 1 s, which is an improvement of more than one to two orders of magnitude over existing systems. Moreover, this fast data collection time has been shown to have no effect on the obtained travel time results. This allows for more careful study of time-dependent phenomena with tighter snapshots in time of processes that would otherwise be lost or averaged out in other acoustic measurement systems.

  8. Acoustic field characterization of the Duolith: Measurements and modeling of a clinical shock wave therapy device

    PubMed Central

    Perez, Camilo; Chen, Hong; Matula, Thomas J.; Karzova, Maria; Khokhlova, Vera A.

    2013-01-01

    Extracorporeal shock wave therapy (ESWT) uses acoustic pulses to treat certain musculoskeletal disorders. In this paper the acoustic field of a clinical portable ESWT device (Duolith SD1) was characterized. Field mapping was performed in water for two different standoffs of the electromagnetic head (15 or 30 mm) using a fiber optic probe hydrophone. Peak positive pressures at the focus ranged from 2 to 45 MPa, while peak negative pressures ranged from −2 to −11 MPa. Pulse rise times ranged from 8 to 500 ns; shock formation did not occur for any machine settings. The maximum standard deviation in peak pressure at the focus was 1.2%, indicating that the Duolith SD1 generates stable pulses. The results compare qualitatively, but not quantitatively with manufacturer specifications. Simulations were carried out for the short standoff by matching a Khokhlov-Zabolotskaya-Kuznetzov equation to the measured field at a plane near the source, and then propagating the wave outward. The results of modeling agree well with experimental data. The model was used to analyze the spatial structure of the peak pressures. Predictions from the model suggest that a true shock wave could be obtained in water if the initial pressure output of the device were doubled. PMID:23927207

  9. Field evaluation of boat-mounted acoustic Doppler instruments used to measure streamflow

    USGS Publications Warehouse

    Mueller, D.S.; ,

    2003-01-01

    The use of instruments based on the Doppler principle for measuring water velocity and computing discharge is common within the U.S. Geological Survey (USGS). The instruments and software have changed appreciably during the last 5 years; therefore, the USGS has begun field validation of the instruments used to make discharge measurements from a moving boat. Instruments manufactured by SonTek/YSI and RD Instruments, Inc. were used to collect discharge data at five different sites. One or more traditional discharge measurements were made using a Price AA current meter and standard USGS procedures concurrent with the acoustic instruments at each site. Discharges measured with the acoustic instruments were compared with discharges measured with Price AA current meters and the USGS stage-discharge rating for each site. The mean discharges measured by each acoustic instrument were within 5 percent of the Price AA-based measurement and (or) discharge from the stage-discharge rating.

  10. Measured acoustic characteristics of ducted supersonic jets at different model scales

    NASA Technical Reports Server (NTRS)

    Jones, R. R., III; Ahuja, K. K.; Tam, Christopher K. W.; Abdelwahab, M.

    1993-01-01

    A large-scale (about a 25x enlargement) model of the Georgia Tech Research Institute (GTRI) hardware was installed and tested in the Propulsion Systems Laboratory of the NASA Lewis Research Center. Acoustic measurements made in these two facilities are compared and the similarity in acoustic behavior over the scale range under consideration is highlighted. The study provide the acoustic data over a relatively large-scale range which may be used to demonstrate the validity of scaling methods employed in the investigation of this phenomena.

  11. The use of electro-acoustic impedance measurements in detecting early clinical otosclerosis.

    PubMed

    Van Wagoner, R S; Campbell, J D

    1976-02-01

    The first evidence that sodium fluoride (NaFl) can stop the otosclerotic process was recently presented. This development has placed new emphasis on the early detection of clinical otosclerosis. Electro-acoustic impedance measurements often detect minute changes in absolute impedance and compliance of the ossicular chain. The most valuable diagnostic information, however, is a negative on-off (biphasic) type of acoustic reflex. These results are often evident prior to the detection of positive clinical signs of otosclerosis. The negative on-off acoustic reflex is reviewed in this paper along with case discussions involving medical/surgical management of early otosclerosis.

  12. Acoustic Response of Underwater Munitions near a Sediment Interface: Measurement Model Comparisons and Classification Schemes

    DTIC Science & Technology

    2015-04-23

    FINAL REPORT Acoustic Response of Underwater Munitions near a Sediment Interface: Measurement Model Comparisons and Classification Schemes SERDP...6 Figure 2. Effect of fish on acoustic color templates during GULFEX12 …………… 8 Figure 3. Selection of targets deployed during TREX13 and BAYEX14...deployed during TREX13 and BAYEX14 …… 29 Figure 16. Ray diagrams for the acoustic ray model …………………………… 29 Figure 17. Model-model and data-model

  13. Perturbations to the neutral atmosphere caused by acoustic gravity waves at thermospheric altitudes as obtained from Dynasonde data

    NASA Astrophysics Data System (ADS)

    Negrea, Catalin; Zabotin, Nikolay; Bullett, Terry

    2015-04-01

    Gravity waves are known to have a major impact on the dynamics of the thermosphere-ionosphere. A number of recent studies addressed the issue of determining the characteristics of thermospheric gravity waves and associated Travelling Ionospheric Disturbances and also their impact on the background system. However, there are currently no methods that would allow for the continuous and uninterrupted study of both the spatial and temporal characteristics of gravity wave activity over a broad range of thermospheric altitudes. We present results obtained using Dynasonde measurements of electron density and ionospheric tilts. The data covers the bottom E- and F-Layers and implicitly contains information on induced perturbations in the horizontal plane at all accessible altitudes. The methodology that we developed is largely automated, allowing for the analysis of large amounts of data. A model of the thermosphere-ionosphere coupling is implemented to infer neutral atmosphere parameters from ionospheric measurements. This is done by accounting for ion-neutral interactions, changes to chemical composition due to wave propagation and the effect of the geomagnetic field. Background neutral temperature, neutral density and neutral composition are used from a numerical model. A sample dataset from October 24th at Wallops Island, Virginia is used to illustrate our approach. The frequency, wavevector components, group velocity, phase speed and amplitude of induced thermospheric and ionospheric perturbations are obtained. These include the TID amplitude as well as the underlying gravity wave amplitude in neutral density, temperature and zonal and meridional winds.

  14. The Ability to Structure Acoustic Material as a Measure of Musical Aptitude. 4. Experiences with Modifications of the Acoustic Structuring Test. Research Bulletin. No. 51.

    ERIC Educational Resources Information Center

    Karma, Kai

    Four new versions of an acoustic structuring test were developed, administered, and analyzed in order to produce better tests and to contribute to better understanding of the abilities measured by these tests. The tests consist of tape recordings of patterns of musical notes played on an electric organ or an acoustic guitar. Item analyses and…

  15. Method of measuring reactive acoustic power density in a fluid

    DOEpatents

    Wheatley, J.C.; Swift, G.W.; Migliori, A.

    1985-09-03

    A method for determining reactive acoustic power density level and its direction in a fluid using a single sensor is disclosed. In the preferred embodiment, an apparatus for conducting the method, which is termed a thermoacoustic couple, consists of a stack of thin, spaced apart polymeric plates, selected ones of which include multiple bimetallic thermocouple junctions positioned along opposite end edges thereof. The thermocouple junctions are connected in series in the nature of a thermopile, and are arranged so as to be responsive to small temperature differences between the opposite edges of the plates. The magnitude of the temperature difference, as represented by the magnitude of the electrical potential difference generated by the thermopile, is found to be directly related to the level of acoustic power density in the gas. 5 figs.

  16. Method of measuring reactive acoustic power density in a fluid

    DOEpatents

    Wheatley, John C.; Swift, Gregory W.; Migliori, Albert

    1985-01-01

    A method for determining reactive acoustic power density level and its direction in a fluid using a single sensor is disclosed. In the preferred embodiment, an apparatus for conducting the method, which is termed a thermoacoustic couple, consists of a stack of thin, spaced apart polymeric plates, selected ones of which include multiple bimetallic thermocouple junctions positioned along opposite end edges thereof. The thermocouple junctions are connected in series in the nature of a thermopile, and are arranged so as to be responsive to small temperature differences between the opposite edges of the plates. The magnitude of the temperature difference, as represented by the magnitude of the electrical potential difference generated by the thermopile, is found to be directly related to the level of acoustic power density in the gas.

  17. Experimental Acoustic Velocity Measurements in a Tidally Affected Stream

    USGS Publications Warehouse

    Storm, J.B.; ,

    2002-01-01

    The U.S. Geological Survey (USGS) constructed a continuous steamgaging station on the tidally affected Escatawpa River at Interstate 10 near Orange Grove, Mississippi, in August 2001. The gage collects water quantity parameters of stage and stream velocity, and water quality parameters of water temperature, specific conductance, and salinity. Data are transmitted to the local USGS office via the GOES satellite and are presented on a near real-time web page. Due to tidal effects, the stream has multiple flow regimes which include downstream, bi-directional, and reverse flows. Advances in acoustic technology have made it possible to gage streams of this nature where conventional methods have been unsuccessful. An experimental mount was designed in an attempt to recognize, describe, and quantify these flow regimes by using acoustic Doppler equipment.

  18. Assessment of systematic measurement errors for acoustic travel-time tomography of the atmosphere.

    PubMed

    Vecherin, Sergey N; Ostashev, Vladimir E; Wilson, D Keith

    2013-09-01

    Two algorithms are described for assessing systematic errors in acoustic travel-time tomography of the atmosphere, the goal of which is to reconstruct the temperature and wind velocity fields given the transducers' locations and the measured travel times of sound propagating between each speaker-microphone pair. The first algorithm aims at assessing the errors simultaneously with the mean field reconstruction. The second algorithm uses the results of the first algorithm to identify the ray paths corrupted by the systematic errors and then estimates these errors more accurately. Numerical simulations show that the first algorithm can improve the reconstruction when relatively small systematic errors are present in all paths. The second algorithm significantly improves the reconstruction when systematic errors are present in a few, but not all, ray paths. The developed algorithms were applied to experimental data obtained at the Boulder Atmospheric Observatory.

  19. Measuring the Kuroshio Current with ocean acoustic tomography.

    PubMed

    Taniguchi, Naokazu; Huang, Chen-Fen; Kaneko, Arata; Liu, Cho-Teng; Howe, Bruce M; Wang, Yu-Huai; Yang, Yih; Lin, Ju; Zhu, Xiao-Hua; Gohda, Noriaki

    2013-10-01

    Ocean current profiling using ocean acoustic tomography (OAT) was conducted in the Kuroshio Current southeast of Taiwan from August 20 to September 15, 2009. Sound pulses were transmitted reciprocally between two acoustic stations placed near the underwater sound channel axis and separated by 48 km. Based on the result of ray simulation, the received signals are divided into multiple ray groups because it is difficult to resolve the ray arrivals for individual rays. The average differential travel times from these ray groups are used to reconstruct the vertical profiles of currents. The currents are estimated with respect to the deepest water layer via two methods: An explicit solution and an inversion with regularization. The strong currents were confined to the upper 200 m and rapidly weakened toward 500 m in depth. Both methods give similar results and are consistent with shipboard acoustic Doppler current profiler results in the upper 150 m. The observed temporal variation demonstrates a similar trend to the prediction from the Hybrid Coordinate Ocean Model.

  20. Comparison between psycho-acoustics and physio-acoustic measurement to determine optimum reverberation time of pentatonic angklung music concert hall

    NASA Astrophysics Data System (ADS)

    Sudarsono, Anugrah S.; Merthayasa, I. G. N.; Suprijanto

    2015-09-01

    This research tried to compare psycho-acoustics and Physio-acoustic measurement to find the optimum reverberation time of soundfield from angklung music. Psycho-acoustic measurement was conducted using a paired comparison method and Physio-acoustic measurement was conducted with EEG Measurement on T3, T4, FP1, and FP2 measurement points. EEG measurement was conducted with 5 persons. Pentatonic angklung music was used as a stimulus with reverberation time variation. The variation was between 0.8 s - 1.6 s with 0.2 s step. EEG signal was analysed using a Power Spectral Density method on Alpha Wave, High Alpha Wave, and Theta Wave. Psycho-acoustic measurement on 50 persons showed that reverberation time preference of pentatonic angklung music was 1.2 second. The result was similar to Theta Wave measurement on FP2 measurement point. High Alpha wave on T4 measurement gave different results, but had similar patterns with psycho-acoustic measurement

  1. Challenges and regulatory considerations in the acoustic measurement of high-frequency (>20 MHz) ultrasound.

    PubMed

    Nagle, Samuel M; Sundar, Guru; Schafer, Mark E; Harris, Gerald R; Vaezy, Shahram; Gessert, James M; Howard, Samuel M; Moore, Mary K; Eaton, Richard M

    2013-11-01

    This article examines the challenges associated with making acoustic output measurements at high ultrasound frequencies (>20 MHz) in the context of regulatory considerations contained in the US Food and Drug Administration industry guidance document for diagnostic ultrasound devices. Error sources in the acoustic measurement, including hydrophone calibration and spatial averaging, nonlinear distortion, and mechanical alignment, are evaluated, and the limitations of currently available acoustic measurement instruments are discussed. An uncertainty analysis of acoustic intensity and power measurements is presented, and an example uncertainty calculation is done on a hypothetical 30-MHz high-frequency ultrasound system. This analysis concludes that the estimated measurement uncertainty of the acoustic intensity is +73%/-86%, and the uncertainty in the mechanical index is +37%/-43%. These values exceed the respective levels in the Food and Drug Administration guidance document of 30% and 15%, respectively, which are more representative of the measurement uncertainty associated with characterizing lower-frequency ultrasound systems. Recommendations made for minimizing the measurement uncertainty include implementing a mechanical positioning system that has sufficient repeatability and precision, reconstructing the time-pressure waveform via deconvolution using the hydrophone frequency response, and correcting for hydrophone spatial averaging.

  2. The use of waveguide acoustic probes for void fraction measurement in the evaporator of BN-350-Type reactor

    SciTech Connect

    Melnikov, V.I.; Nigmatulin, B.I.

    1995-09-01

    The present paper deals with some results of the experimental studies which have been carried out to investigate the steam generation dynamics in the Field tubes of sodium-water evaporators used in the BN-350 reactors. The void fraction measurements have been taken with the aid of waveguide acoustic transducers manufactured in accordance with a specially designed technology (waveguide acoustic transducers-WAT technology). Presented in this paper also the transducer design and calibration methods, as well as the diagram showing transducers arrengment in the evaporator. The transducers under test featured a waveguide of about 4 m in length and a 200-mm long sensitive element (probe). Besides, this paper specifies the void fraction data obtained through measurements in diverse points of the evaporator. The studies revealed that the period of observed fluctuations in the void fraction amounted to few seconds and was largely dependent on the level of water in the evaporator.

  3. A Methodology to Integrate Magnetic Resonance and Acoustic Measurements for Reservoir Characterization

    SciTech Connect

    Parra, Jorge O.; Hackert, Chris L.; Collier, Hughbert A.; Bennett, Michael

    2002-01-29

    The objective of this project was to develop an advanced imaging method, including pore scale imaging, to integrate NMR techniques and acoustic measurements to improve predictability of the pay zone in hydrocarbon reservoirs. This is accomplished by extracting the fluid property parameters using NMR laboratory measurements and the elastic parameters of the rock matrix from acoustic measurements to create poroelastic models of different parts of the reservoir. Laboratory measurement techniques and core imaging are being linked with a balanced petrographical analysis of the core and theoretical model.

  4. A Methodology to Integrate Magnetic Resonance and Acoustic Measurements for Reservoir Characterization

    SciTech Connect

    Parra, Ph.D., Jorge O.

    2002-06-10

    The objective of the project was to develop an advanced imaging method, including pore scale imaging, to integrate nuclear magnetic resonance (NMR) techniques and acoustic measurements to improve predictability of the pay zone in hydrocarbon reservoirs. This will be accomplished by extracting the fluid property parameters using NMR laboratory measurements and the elastic parameters of the rock matrix from acoustic measurements to create poroelastic models of different parts of the reservoir. Laboratory measurement techniques and core imaging were linked with a balanced petrographical analysis of cores and theoretical modeling.

  5. A Methodology to Integrate Magnetic Resonance and Acoustic Measurements for Reservoir Characterization

    SciTech Connect

    Parra, J.O.

    2001-01-26

    The objective of this project was to develop an advanced imaging method, including pore scale imaging, to integrate magnetic resonance (MR) techniques and acoustic measurements to improve predictability of the pay zone in two hydrocarbon reservoirs. This was accomplished by extracting the fluid property parameters using MR laboratory measurements and the elastic parameters of the rock matrix from acoustic measurements to create poroelastic models of different parts of the reservoir. Laboratory measurements were compared with petrographic analysis results to determine the relative roles of petrographic elements such as porosity type, mineralogy, texture, and distribution of clay and cement in creating permeability heterogeneity.

  6. Measured wavenumber: frequency spectrum associated with acoustic and aerodynamic wall pressure fluctuations.

    PubMed

    Arguillat, Blandine; Ricot, Denis; Bailly, Christophe; Robert, Gilles

    2010-10-01

    Direct measurements of the wavenumber-frequency spectrum of wall pressure fluctuations beneath a turbulent plane channel flow have been performed in an anechoic wind tunnel. A rotative array has been designed that allows the measurement of a complete map, 63×63 measuring points, of cross-power spectral densities over a large area. An original post-processing has been developed to separate the acoustic and the aerodynamic exciting loadings by transforming space-frequency data into wavenumber-frequency spectra. The acoustic part has also been estimated from a simple Corcos-like model including the contribution of a diffuse sound field. The measured acoustic contribution to the surface pressure fluctuations is 5% of the measured aerodynamic surface pressure fluctuations for a velocity and boundary layer thickness relevant for automotive interior noise applications. This shows that for aerodynamically induced car interior noise, both contributions to the surface pressure fluctuations on car windows have to be taken into account.

  7. Behavioral and electrophysiological auditory processing measures in traumatic brain injury after acoustically controlled auditory training: a long-term study

    PubMed Central

    Figueiredo, Carolina Calsolari; de Andrade, Adriana Neves; Marangoni-Castan, Andréa Tortosa; Gil, Daniela; Suriano, Italo Capraro

    2015-01-01

    ABSTRACT Objective To investigate the long-term efficacy of acoustically controlled auditory training in adults after tarumatic brain injury. Methods A total of six audioogically normal individuals aged between 20 and 37 years were studied. They suffered severe traumatic brain injury with diffuse axional lesion and underwent an acoustically controlled auditory training program approximately one year before. The results obtained in the behavioral and electrophysiological evaluation of auditory processing immediately after acoustically controlled auditory training were compared to reassessment findings, one year later. Results Quantitative analysis of auditory brainsteim response showed increased absolute latency of all waves and interpeak intervals, bilaterraly, when comparing both evaluations. Moreover, increased amplitude of all waves, and the wave V amplitude was statistically significant for the right ear, and wave III for the left ear. As to P3, decreased latency and increased amplitude were found for both ears in reassessment. The previous and current behavioral assessment showed similar results, except for the staggered spondaic words in the left ear and the amount of errors on the dichotic consonant-vowel test. Conclusion The acoustically controlled auditory training was effective in the long run, since better latency and amplitude results were observed in the electrophysiological evaluation, in addition to stability of behavioral measures after one-year training. PMID:26676270

  8. An objective method and measuring equipment for noise control and acoustic diagnostics of motorcars. [acoustic diagnostics on automobile engines

    NASA Technical Reports Server (NTRS)

    Kacprowski, J.; Motylewski, J.; Miazga, J.

    1974-01-01

    An objective method and apparatus for noise control and acoustic diagnostics of motorcar engines are reported. The method and apparatus let us know whether the noisiness of the vehicle under test exceeds the admissible threshold levels given by appropriate standards and if so what is the main source of the excessive noise. The method consists in measuring both the overall noise level and the sound pressure levels in definite frequency bands while the engine speed is controlled as well and may be fixed at prescribed values. Whenever the individually adjusted threshold level has been exceeded in any frequency band, a self-sustaining control signal is sent.

  9. Measurement of the acoustic radiation force on a sphere embedded in a soft solid

    NASA Astrophysics Data System (ADS)

    Lidon, Pierre; Villa, Louis; Taberlet, Nicolas; Manneville, Sébastien

    2017-01-01

    The acoustic radiation force exerted on a small sphere located at the focus of an ultrasonic beam is measured in a soft gel. It is proved to evolve quadratically with the local amplitude of the acoustic field. Strong oscillations of the local pressure are observed and attributed to an acoustic Fabry-Pérot effect between the ultrasonic emitter and the sphere. Taking this effect into account with a simple model, a quantitative link between the radiation force and the acoustic pressure is proposed and compared to theoretical predictions in the absence of dissipation. The discrepancy between experiment and theory suggests that dissipative effects should be taken into account for fully modeling the observations.

  10. Reproducibility experiments on measuring acoustical properties of rigid-frame porous media (round-robin tests).

    PubMed

    Horoshenkov, Kirill V; Khan, Amir; Bécot, François-Xavier; Jaouen, Luc; Sgard, Franck; Renault, Amélie; Amirouche, Nesrine; Pompoli, Francesco; Prodi, Nicola; Bonfiglio, Paolo; Pispola, Giulio; Asdrubali, Francesco; Hübelt, Jörn; Atalla, Noureddine; Amédin, Celse K; Lauriks, Walter; Boeckx, Laurens

    2007-07-01

    This paper reports the results of reproducibility experiments on the interlaboratory characterization of the acoustical properties of three types of consolidated porous media: granulated porous rubber, reticulated foam, and fiberglass. The measurements are conducted in several independent laboratories in Europe and North America. The studied acoustical characteristics are the surface complex acoustic impedance at normal incidence and plane wave absorption coefficient which are determined using the standard impedance tube method. The paper provides detailed procedures related to sample preparation and installation and it discusses the dispersion in the acoustical material property observed between individual material samples and laboratories. The importance of the boundary conditions, homogeneity of the porous material structure, and stability of the adopted signal processing method are highlighted.

  11. ATK Launch Vehicle (ALV-X1) Liftoff Acoustic Environments: Prediction vs. Measurement

    NASA Technical Reports Server (NTRS)

    Houston, Janice; Counter, Douglas; Kenny, Jeremy; Murphy, John

    2009-01-01

    The ATK Launch Vehicle (ALV-X1) provided an opportunity to measure liftoff acoustic noise data. NASA Marshall Space Flight Center (MSFC) engineers were interested in the ALV-X1 launch because the First Stage motor and launch pad conditions, including a relativity short deflector ducting, provide a potential analogue to future Ares I launches. This paper presents the measured liftoff acoustics on the vehicle and tower. Those measured results are compared to predictions based upon the method described in NASA SP-8072 "Acoustic Loads Generated by the Propulsion System" and the Vehicle Acoustic Environment Prediction Program (VAEPP) which was developed by MSFC acoustics engineers. One-third octave band sound pressure levels will be presented. This data is useful for the ALV-X1 in validating the pre-launch environments and loads predictions. Additionally, the ALV-X1 liftoff data can be scaled to define liftoff environments for the NASA Constellation program Ares vehicles. Vehicle liftoff noise is caused by the supersonic jet flow interaction with surrounding atmosphere or more simply, jet noise. As the vehicle's First Stage motor is ignited, an acoustic noise field is generated by the exhaust. This noise field persists due to the supersonic jet noise and reflections from the launch pad and tower, then changes as the vehicle begins to liftoff from the launch pad. Depending on launch pad and adjacent tower configurations, the liftoff noise is generally very high near the nozzle exit and decreases rapidly away from the nozzle. The liftoff acoustic time range of interest is typically 0 to 20 seconds after ignition. The exhaust plume thermo-fluid mechanics generates sound at approx.10 Hz to 20 kHz. Liftoff acoustic noise is usually the most severe dynamic environment for a launch vehicle or payload in the mid to high frequency range (approx.50 to 2000 Hz). This noise environment can induce high-level vibrations along the external surfaces of the vehicle and surrounding

  12. Optimizing Vowel Formant Measurements in Four Acoustic Analysis Systems for Diverse Speaker Groups

    PubMed Central

    Derdemezis, Ekaterini; Kent, Ray D.; Fourakis, Marios; Reinicke, Emily L.; Bolt, Daniel M.

    2016-01-01

    Purpose This study systematically assessed the effects of select linear predictive coding (LPC) analysis parameter manipulations on vowel formant measurements for diverse speaker groups using 4 trademarked Speech Acoustic Analysis Software Packages (SAASPs): CSL, Praat, TF32, and WaveSurfer. Method Productions of 4 words containing the corner vowels were recorded from 4 speaker groups with typical development (male and female adults and male and female children) and 4 speaker groups with Down syndrome (male and female adults and male and female children). Formant frequencies were determined from manual measurements using a consensus analysis procedure to establish formant reference values, and from the 4 SAASPs (using both the default analysis parameters and with adjustments or manipulations to select parameters). Smaller differences between values obtained from the SAASPs and the consensus analysis implied more optimal analysis parameter settings. Results Manipulations of default analysis parameters in CSL, Praat, and TF32 yielded more accurate formant measurements, though the benefit was not uniform across speaker groups and formants. In WaveSurfer, manipulations did not improve formant measurements. Conclusions The effects of analysis parameter manipulations on accuracy of formant-frequency measurements varied by SAASP, speaker group, and formant. The information from this study helps to guide clinical and research applications of SAASPs. PMID:26501214

  13. Acoustic characterization of high intensity focused ultrasound fields: A combined measurement and modeling approach

    PubMed Central

    Canney, Michael S.; Bailey, Michael R.; Crum, Lawrence A.; Khokhlova, Vera A.; Sapozhnikov, Oleg A.

    2008-01-01

    Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24 000 W∕cm2. The inputs to a Khokhlov–Zabolotskaya–Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W∕cm2, lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields. PMID:19062878

  14. Acoustic characterization of high intensity focused ultrasound fields: a combined measurement and modeling approach.

    PubMed

    Canney, Michael S; Bailey, Michael R; Crum, Lawrence A; Khokhlova, Vera A; Sapozhnikov, Oleg A

    2008-10-01

    Acoustic characterization of high intensity focused ultrasound (HIFU) fields is important both for the accurate prediction of ultrasound induced bioeffects in tissues and for the development of regulatory standards for clinical HIFU devices. In this paper, a method to determine HIFU field parameters at and around the focus is proposed. Nonlinear pressure waveforms were measured and modeled in water and in a tissue-mimicking gel phantom for a 2 MHz transducer with an aperture and focal length of 4.4 cm. Measurements were performed with a fiber optic probe hydrophone at intensity levels up to 24,000 W/cm(2). The inputs to a Khokhlov-Zabolotskaya-Kuznetsov-type numerical model were determined based on experimental low amplitude beam plots. Strongly asymmetric waveforms with peak positive pressures up to 80 MPa and peak negative pressures up to 15 MPa were obtained both numerically and experimentally. Numerical simulations and experimental measurements agreed well; however, when steep shocks were present in the waveform at focal intensity levels higher than 6000 W/cm(2), lower values of the peak positive pressure were observed in the measured waveforms. This underrepresentation was attributed mainly to the limited hydrophone bandwidth of 100 MHz. It is shown that a combination of measurements and modeling is necessary to enable accurate characterization of HIFU fields.

  15. Measurements of Infrared and Acoustic Source Distributions in Jet Plumes

    NASA Technical Reports Server (NTRS)

    Agboola, Femi A.; Bridges, James; Saiyed, Naseem

    2004-01-01

    The aim of this investigation was to use the linear phased array (LPA) microphones and infrared (IR) imaging to study the effects of advanced nozzle-mixing techniques on jet noise reduction. Several full-scale engine nozzles were tested at varying power cycles with the linear phased array setup parallel to the jet axis. The array consisted of 16 sparsely distributed microphones. The phased array microphone measurements were taken at a distance of 51.0 ft (15.5 m) from the jet axis, and the results were used to obtain relative overall sound pressure levels from one nozzle design to the other. The IR imaging system was used to acquire real-time dynamic thermal patterns of the exhaust jet from the nozzles tested. The IR camera measured the IR radiation from the nozzle exit to a distance of six fan diameters (X/D(sub FAN) = 6), along the jet plume axis. The images confirmed the expected jet plume mixing intensity, and the phased array results showed the differences in sound pressure level with respect to nozzle configurations. The results show the effects of changes in configurations to the exit nozzles on both the flows mixing patterns and radiant energy dissipation patterns. By comparing the results from these two measurements, a relationship between noise reduction and core/bypass flow mixing is demonstrated.

  16. Discharge-measurement system using an acoustic Doppler current profiler with applications to large rivers and estuaries

    USGS Publications Warehouse

    Simpson, Michael R.; Oltmann, Richard N.

    1993-01-01

    Discharge measurement of large rivers and estuaries is difficult, time consuming, and sometimes dangerous. Frequently, discharge measurements cannot be made in tide-affected rivers and estuaries using conventional discharge-measurement techniques because of dynamic discharge conditions. The acoustic Doppler discharge-measurement system (ADDMS) was developed by the U.S. Geological Survey using a vessel-mounted acoustic Doppler current profiler coupled with specialized computer software to measure horizontal water velocity at 1-meter vertical intervals in the water column. The system computes discharge from water-and vessel-velocity data supplied by the ADDMS using vector-algebra algorithms included in the discharge-measurement software. With this system, a discharge measurement can be obtained by engaging the computer software and traversing a river or estuary from bank to bank; discharge in parts of the river or estuarine cross sections that cannot be measured because of ADDMS depth limitations are estimated by the system. Comparisons of ADDMS-measured discharges with ultrasonic-velocity-meter-measured discharges, along with error-analysis data, have confirmed that discharges provided by the ADDMS are at least as accurate as those produced using conventional methods. In addition, the advantage of a much shorter measurement time (2 minutes using the ADDMS compared with 1 hour or longer using conventional methods) has enabled use of the ADDMS for several applications where conventional discharge methods could not have been used with the required accuracy because of dynamic discharge conditions.

  17. Comparative study of mandibular linear measurements obtained by cone beam computed tomography and digital calipers

    PubMed Central

    Tarazona-Álvarez, Pablo; Romero-Millán, Javier; Peñarrocha-Oltra, David; Fuster-Torres, María Á.; Tarazona, Beatriz

    2014-01-01

    Objectives: Cone beam computed tomography (CBCT) is an innovative dental of imaging system characterized by rapid volumetric imaging with patient exposure to a single dose of radiation. The present study was carried out to compare the linear measurements obtained with CBCT and digital caliper in 20 mandibles from human cadavers. Study design: A total of 4800 linear measurements were measured between different mandibular anatomical points with CBCT and digital caliper. The real measurements were defined as those obtained with the digital caliper. Posteriorly, the mandibles were scanned to obtain the CBCT images, with software-based measurements of the distances. Results: The measurements obtained with the digital caliper were greater. The CBCT technique underestimated distances greater than 100 mm. Conclusions: CBCT allows to obtain linear mandibular anatomical measurements equivalent to those obtained with digital caliper. The differences existing between both methods were clinically acceptable. Key words:Computed tomography, cone beam CT, accuracy, reliability, digital caliper. PMID:25136429

  18. Hearing preservation in acoustic neuroma resection: Analysis of petrous bone measurement and intraoperative application

    PubMed Central

    Tanrikulu, Levent; Lohse, Peer; Fahlbusch, Rudolf; Naraghi, Ramin

    2016-01-01

    Background: There is an increased risk for labyrinthine injury for the resection of acoustic neuromas (AN) on the suboccipital, retrosigmoid approach. Prognostic factors should be analyzed for the postoperative hearing function. Methods: We examined 51 patients with ANs using preoperative intact hearing function. Audiological data were obtained by pure tone audiogram (PTA) and speech audiogram. The preoperative and postoperative anatomical localization of the labyrinth was measured with specific distances regarding the tumor and corresponding anatomy of the posterior fossa by high-resolution magnetic resonance imaging (MRI). Results: Postoperative MRI controls confirmed no injuries to the labyrinth (0%). The postoperative hearing results showed 100% hearing preservation for T1-tumors (<1 ml/<1.1 cm), 50% for T2-tumors (1–4 ml/1.1–1.8 cm), 40% for T3-tumors (4–8 ml/1.8–2.3 cm) and 18% for T4-tumors (>8 ml/>2.3 cm). Postoperative deafness was seen in all cases with ventral tumor extension higher than 5.5 mm. Postoperative loss of hearing was seen in all cases with hearing preservation with 6–8% of speech discrimination and an increase in the hearing threshold of 12 dB in the PTA compared to the preoperative hearing status. Conclusion: Petrous bone measurement by high-resolution MRI data enables safe surgical exposure of the internal acoustic canal with avoidance of injury to the labyrinth and a better postoperative prognosis, especially for intrameatal ANs and for the resection of intrameatal portions of larger neuromas. The prognostic factors enable the patients and the surgeon a better estimation of postoperative results regarding deafness and postoperative hypacusis and support a consolidated treatment planning. PMID:28144470

  19. Acoustical environment measurement at a very shallow port: Trial case in Hashirimizu Port

    NASA Astrophysics Data System (ADS)

    Ogasawara, Hanako; Mori, Kazuyoshi

    2016-07-01

    Recently, the needs for coastal environment measurement has been increasing for many purposes, such as fishing, weather forecasting, ocean noise measurement for power plants, and coastal security. Acoustical measurement is one of the solutions because it can cover a wide area with few sensors, and it is possible to monitor long term or in real time. In this study, a small-scale reciprocal sound travel experiment was carried out in Hashirimizu Port for coastal environment measurement, such as current speed and water temperature. Since the distance between the surface and the transducer becomes short according to the tidal effect, the direct signal is canceled by the surface-reflected signal under a specific condition. However, even under such a condition, mean water temperature could be estimated from the reciprocal travel time using bottom-reflected signals. The current along the travel path was a reasonable value. It is possible to obtain a special current speed with another reciprocal path, which is in a direction perpendicular to the current travel path.

  20. The neonatal acoustic reflex.

    PubMed

    Weatherby, L A; Bennett, M J

    1980-01-01

    Probe tones from 220 Hz to 2 000 Hz were used to measure the static and dynamic acoustic impedance of 44 neonates. Acoustic reflex thresholds to broad band noise were obtained from every neonate tested when employing the higher frequency probe tones. The reflex threshold levels measured are similar to those of adults. The static impedance values are discussed to give a possible explanation of why reflex thresholds cannot be detected using conventional 220 Hz impedance bridges.

  1. Basaltic thermals and Subplinian plumes: Constraints from acoustic measurements at Shishaldin volcano, Alaska

    USGS Publications Warehouse

    Vergniolle, Sylvie; Caplan-Auerbach, Jacqueline

    2006-01-01

    The 1999 basaltic eruption of Shishaldin volcano (Alaska, USA) included both Strombolian and Subplinian activity, as well as a “pre-Subplinian” phase interpreted as the local coalescence within a long foam in the conduit. Although few visual observations were made of the eruption, a great deal of information regarding gas velocity, gas flux at the vent and plume height may be inferred by using acoustic recordings of the eruption. By relating acoustic power to gas velocity, a time series of gas velocity is calculated for the Subplinian and pre-Subplinian phases. These time series show trends in gas velocity that are interpreted as plumes or, for those signals lasting only a short time, thermals. The Subplinian phase is shown to be composed of a thermal followed by five plumes with a total expelled gas volume of ≈1.5×107m3">≈1.5×107m3.The initiation of the Subplinian activity is probably related to the arrival of a large overpressurised bubble close to the top of the magma column. A gradual increase in low-frequency (0.01–0.5 Hz) signal prior to this “trigger bubble” may be due to the rise of the bubble in the conduit. This delay corresponds to a reservoir located at ≈3.9 km below the surface, in good agreement with studies on other volcanoes.The presence of two thermal phases is also identified in the middle of the pre-Subplinian phase with a total gas release of ≈4.3×106m3">≈4.3×106m3 and ≈3.6×106m3">≈3.6×106m3. Gas velocity at the vent is found to be ≈82m.s−1">≈82m.s−1 and ≈90m.s−1">≈90m.s−1 for the Subplinian plumes and the pre-Subplinian thermals respectively.The agreement is very good between estimates of the gas flux from modelling the plume height and those obtained from acoustic measurements, leading to a new method by which eruption physical parameters may be quantified. Furthermore, direct measurements of gas velocity can be used for better estimates of the SO2">SO2 flux released during the eruption.

  2. Correlation of orofacial speeds with voice acoustic measures in the fluent speech of persons who stutter.

    PubMed

    McClean, Michael D; Tasko, Stephen M

    2004-12-01

    Stuttering is often viewed as a problem in coordinating the movements of different muscle systems involved in speech production. From this perspective, it is logical that efforts be made to quantify and compare the strength of neural coupling between muscle systems in persons who stutter (PS) and those who do not stutter (NS). This problem was addressed by correlating the speeds of different orofacial structures with vowel fundamental frequency (F0) and intensity as subjects produced fluent repetitions of a simple nonsense phrase at habitual, high, and low intensity levels. It is assumed that resulting correlations indirectly reflect the strength of neural coupling between particular orofacial structures and the respiratory-laryngeal system. An electromagnetic system was employed to record movements of the upper lip, lower lip, tongue, and jaw in 43 NS and 39 PS. The acoustic speech signal was recorded and used to obtain measures of vowel F0 and intensity. For each subject, correlation measures were obtained relating peak orofacial speeds to F0 and intensity. Correlations were significantly reduced in PS compared to NS for the lower lip and tongue, although the magnitude of these group differences covaried with the correlation levels relating F0 and intensity. It is suggested that the group difference in correlation pattern reflects a reduced strength of neural coupling of the lower lip and tongue systems to the respiratory-laryngeal system in PS. Consideration is given to how this may contribute to temporal discoordination and stuttering.

  3. A hybrid deconvolution approach to separate static and moving single-tone acoustic sources by phased microphone array measurements

    NASA Astrophysics Data System (ADS)

    Mo, Pinxi; Jiang, Weikang

    2017-02-01

    Beamforming approaches are developed to locate and quantify either static or moving acoustic sources by phased microphone array measurements. They would meet difficulties in mapping combined sources consisting of both static and moving sources. In this work, a hybrid deconvolution approach is proposed to separate static and moving single-tone sources. The approach is derived based on the source independence assumption as in the Deconvolution Approach for the Mapping of Acoustic Sources (DAMAS). The static beamforming and the moving beamforming are integrated to construct a linear matrix equation. The source distributions for the static sources and moving sources are simultaneously obtained by solving the equation. Numerical simulations and experiments were implemented on the combined sources with one static source and one rotating source. From the results, the hybrid deconvolution approach shows its effectiveness in separating the two sources, even with large source strength differences.

  4. Wideband Acoustic Immittance: Normative Study and Test-Retest Reliability of Tympanometric Measurements in Adults

    ERIC Educational Resources Information Center

    Sun, Xiao-Ming

    2016-01-01

    Purpose: The purpose of this study was to present normative data of tympanometric measurements of wideband acoustic immittance and to characterize wideband tympanograms. Method: Data were collected in 84 young adults with strictly defined normal hearing and middle ear status. Energy absorbance (EA) was measured using clicks for 1/12-octave…

  5. Acoustic measurement of suspensions of clay and silt particles using single frequency attenuation and backscatter

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The use of ultrasonic acoustic technology to measure the concentration of fine suspended sediments has the potential to greatly increase the temporal and spatial resolution of sediment measurements while reducing the need for personnel to be present at gauging stations during storm events. The conv...

  6. Final Report: Geothermal dual acoustic tool for measurement of rock stress

    SciTech Connect

    Normann, Randy A.

    2014-12-01

    This paper outlines the technology need for a rock formation stress measurement in future EGS wells. This paper reports on the results of work undertaken under a Phase I, DOE/SBIR on the feasibility to build an acoustic well logging tool for measuring rock formation stress.

  7. Final Report. Geothermal Dual Acoustic Tool for Measurement of Rock Stress

    SciTech Connect

    Normann, Randy A

    2014-12-01

    This paper outlines the technology need for a rock formation stress measurement in future EGS wells. This paper reports on the results of work undertaken under a Phase I, DOE/SBIR on the feasibility to build an acoustic well logging tool for measuring rock formation stress.

  8. Surface Reflection Phase in Two Way Acoustic Signal in Oceanic Crustal Deformation Measurement

    NASA Astrophysics Data System (ADS)

    Ikuta, R.; Tadokoro, K.; Watanabe, T.; Nagai, S.; Okuda, T.

    2011-12-01

    We are developing a geodetic method of monitoring crustal deformation under the ocean using kinematic GPS and acoustic ranging. The measurements are done by measuring two way traveltime of supersonic signal between a vessel, whose position is precisely determined by kinematic GPS, and transponders array (benchmark) on the ocean bottom. The goal of our research is to achieve sub-centimeter accuracy in measuring position of the benchmark by a very short-time measurement like 10 hours. In this study, we focused the under-water acoustic part of the system to improve data acquisition rate and then number of observation equations to solve the position of the benchmark with better accuracy. The measurements have started in Suruga Bay in 2003 and in Kumano Basin in 2004, which have been repeated a few times in a year. The accuracy of the benchmark positioning depends on the quality and quantity of the acoustic signal data. We are using M-sequence signal because of its robustness against ambient noises (The signal length is 14.322ms, Carrier frequency is 12.987kHz). We calculate cross-correlation between emitted and received signal and then accept the signal with cross correlation coefficient higher than a threshold. However, we often failed to achieve well correlated signals and then obtain very few traveltime data through one cruise. Sometimes in the cruise of good condition, 70 % of acoustic data have correlation coefficient above 0.7, on the other hand, only 10 % of all the data have correlation coefficient of 0.7 in bad condition cruise. We found that increase of ambient noise and contamination of later phase resembling to the main signal occurs independently each other. The ambient noise should be due to screw noise of the vessel because the noise grew up when sailing against the wind and current. On the other hand the later phases have following features: 1. Arrive in between 1 and 2 ms after the main signal arrival 2. The cross-correlation coefficient sometimes

  9. Measurement of Aqueous Foam Rheology by Acoustic Levitation

    NASA Technical Reports Server (NTRS)

    McDaniel, J. Gregory; Holt, R. Glynn; Rogers, Rich (Technical Monitor)

    2000-01-01

    An experimental technique is demonstrated for acoustically levitating aqueous foam drops and exciting their spheroidal modes. This allows fundamental studies of foam-drop dynamics that provide an alternative means of estimating the viscoelastic properties of the foam. One unique advantage of the technique is the lack of interactions between the foam and container surfaces, which must be accounted for in other techniques. Results are presented in which a foam drop with gas volume fraction phi = 0.77 is levitated at 30 kHz and excited into its first quadrupole resonance at 63 +/- 3 Hz. By modeling the drop as an elastic sphere, the shear modulus of the foam was estimated at 75 +/- 3 Pa.

  10. Measuring the speed of light with baryon acoustic oscillations.

    PubMed

    Salzano, Vincenzo; Dąbrowski, Mariusz P; Lazkoz, Ruth

    2015-03-13

    In this Letter, we describe a new method to use baryon acoustic oscillations (BAO) to derive a constraint on the possible variation of the speed of light. The method relies on the fact that there is a simple relation between the angular diameter distance (D(A)) maximum and the Hubble function (H) evaluated at the same maximum-condition redshift, which includes speed of light c. We note the close analogy of the BAO probe with a laboratory experiment: here we have D(A) which plays the role of a standard (cosmological) ruler, and H^{-1}, with the dimension of time, as a (cosmological) clock. We evaluate if current or future missions such as Euclid can be sensitive enough to detect any variation of c.

  11. a Rayleigh Wave Technique to Measure the Acoustic Nonlinearity Parameter of Materials

    NASA Astrophysics Data System (ADS)

    Shui, G.; Jacobs, L. J.; Qu, J.; Wang, Y. S.; Kim, J.-Y.

    2008-02-01

    Nonlinear ultrasonic techniques have shown great potential for evaluating accumulated damage early in the fatigue life, and ultimately for predicting remaining lifetime of a structural component. The acoustic nonlinearity parameter, a direct measure of the accumulated fatigue damage, is determined from the second harmonic amplitude in finite amplitude sinusoidal ultrasonic waves transmitted through the material. An absolute determination of the acoustic nonlinear parameter is notoriously difficult for several reasons. In this paper, a new experimental technique based on Rayleigh surface waves is presented for determining the absolute acoustic nonlinearity parameter of a relatively thin material specimen. Rayleigh waves are efficiently generated in a specimen by exciting at its edge, and the surface normal velocity of the propagating Rayleigh waves is measured with a laser interferometer system. The high efficiency of the excitation method allows us to drive the transmitting piezoelectric transducer as low as 60 Vpp, and thus to avoid the inherent harmonic distortion from the transducer. The absolute acoustic nonlinearity parameter is then determined from the measured magnitudes of the fundamental and second harmonic surface normal velocities. This technique is applied to determining the acoustic nonlinearity parameters of aluminum alloys 2024 and 6061; the results are compared with those available in the literature. The present technique is especially well-suited for relatively thin components, and much simpler and efficient than the traditional longitudinal wave technique.

  12. Measuring Ultrasonic Acoustic Velocity in a Thin Sheet of Graphite Epoxy Composite

    NASA Technical Reports Server (NTRS)

    2008-01-01

    A method for measuring the acoustic velocity in a thin sheet of a graphite epoxy composite (GEC) material was investigated. This method uses two identical acoustic-emission (AE) sensors, one to transmit and one to receive. The delay time as a function of distance between sensors determines a bulk velocity. A lightweight fixture (balsa wood in the current implementation) provides a consistent method of positioning the sensors, thus providing multiple measurements of the time delay between sensors at different known distances. A linear fit to separation, x, versus delay time, t, will yield an estimate of the velocity from the slope of the line.

  13. Use of Acoustic Doppler Instruments for Measuring Discharge in Streams with Appreciable Sediment Transport

    USGS Publications Warehouse

    Mueller, D.S.; ,

    2002-01-01

    The use of Acoustic Doppler current profilers (ADCP) for measuring discharge in streams with sediment transport was discussed. The studies show that the acoustic frequency of an ADCP in combination with the sediment transport characteristics in a river causes the ADCP bottom-tracking algorithms to detect a moving bottom. A moving bottom causes bottom-tracking-referenced water velocities and discharges to be biased low. The results also show that the use of differential global positioning system (DGPS) data allows accurate measurement of water velocities and discharges in such cases.

  14. Acoustic mapping velocimetry

    NASA Astrophysics Data System (ADS)

    Muste, M.; Baranya, S.; Tsubaki, R.; Kim, D.; Ho, H.; Tsai, H.; Law, D.

    2016-05-01

    Knowledge of sediment dynamics in rivers is of great importance for various practical purposes. Despite its high relevance in riverine environment processes, the monitoring of sediment rates remains a major and challenging task for both suspended and bed load estimation. While the measurement of suspended load is currently an active area of testing with nonintrusive technologies (optical and acoustic), bed load measurement does not mark a similar progress. This paper describes an innovative combination of measurement techniques and analysis protocols that establishes the proof-of-concept for a promising technique, labeled herein Acoustic Mapping Velocimetry (AMV). The technique estimates bed load rates in rivers developing bed forms using a nonintrusive measurements approach. The raw information for AMV is collected with acoustic multibeam technology that in turn provides maps of the bathymetry over longitudinal swaths. As long as the acoustic maps can be acquired relatively quickly and the repetition rate for the mapping is commensurate with the movement of the bed forms, successive acoustic maps capture the progression of the bed form movement. Two-dimensional velocity maps associated with the bed form migration are obtained by implementing algorithms typically used in particle image velocimetry to acoustic maps converted in gray-level images. Furthermore, use of the obtained acoustic and velocity maps in conjunction with analytical formulations (e.g., Exner equation) enables estimation of multidirectional bed load rates over the whole imaged area. This paper presents a validation study of the AMV technique using a set of laboratory experiments.

  15. Measurement of acoustic absorption coefficient with phase-conjugate ultrasonic waves

    NASA Astrophysics Data System (ADS)

    Smagin, N. V.; Krutyansky, L. M.; Brysev, A. P.; Bunkin, F. V.

    2011-07-01

    Experimental results on measurements of the acoustic absorption coefficient in test objects that were obtained with two methods, i.e., a standard insert-substitution method and a modification thereof using phase-conjugate waves, are given. Samples of gelatin and biological tissue in vitro (porcine muscle fibers) were used as test objects. Gelatin objects were manufactured that were both homogeneous and with inhomogeneities in the form of a rough surface or inclusions (air bubbles) distributed over the volume. A rough surface leads mainly to phase distortions of a probe beam, while bubble inclusions cause additional field scattering. For all homogeneous samples, both compared methods produce identical results. In the case of inhomogeneous samples including biological tissues, absorption measurement by a standard method may lead to significant errors. It is demonstrated that the use of properties of phase-conjugate waves provides an opportunity to eliminate almost completely the measurement error connected with phase distortions and reduce the error in the case of a medium with scatterers.

  16. Measurement of the acoustic reflectivity of sirenia (Florida manatees) at 171 kHz.

    PubMed

    Jaffe, Jules S; Simonet, Fernando; Roberts, Paul L D; Bowles, Ann E

    2007-01-01

    The Florida manatee (Trichechus manatus latirostris) is an endangered sirenian. At present, its adult population (approximately 2200) seems stable, but tenuous. Manatee-boat collisions are a significant proportion (approximately 25%) of mortalities. Here, the potential use of active sonar for detecting manatees by quantifying sonic reflectivity is explored. In order to estimate reflectivity two methods were used. One method measured live reflections from captive animals using a carefully calibrated acoustic and co-registered optical system. The other method consisted of the analysis of animal tissue in order to obtain estimates of the sound speed and density and to predict reflectivity. The impedance measurement predicts that for a lateral view, the tissue reflectivity is close to 0.13, with a critical grazing angle of 28 degrees. Data measured from live animals indicate that substantial reflections can be recorded, however in many instances observed "empirical target strengths" were less than an experimentally dependent -48-dB threshold. Conclusions favor the hypothesis that the animals reflect substantial amounts of sound; however, the reflections can often be specular, and therefore impractical for observation by a manatee detection sonar operating at 171 kHz.

  17. Quasi-residual strain and moduli measurements in materials using embedded acoustic waveguides

    NASA Astrophysics Data System (ADS)

    Harrold, Ronald T.; Sanjana, Zal N.; Raju, Basavaraju B.

    1996-11-01

    Following the processing and manufacture of resin and composite parts and during their lifetime, the distribution of internal residual strain and any variations in moduli are generally unknown. Real-time information on these parameters would be valuable for improving material performance and reliability. It is believed that measurements related to material residual stresses or strain and moduli can be obtained by measuring the longitudinal wave velocities within acoustic waveguides (AWG) embedded within a material. The concept is that the wave velocities within embedded AWG are related to the material bulk modulus, density and Poisson's Ratio which are all in some degree related to the material state of cure, and finally the internal residual stresses. Based on this concept it is shown that the AWG of different diameters embedded within the same resin part of uniform internal stress distribution, the AWG wave velocities should vary in relation to the square root of the AWG diameter. Experimental results using AWG of 5, 10, 16, 20, 40 and 62 mil diameter Nichrome embedded within Shell 815 clear resin with optically measured uniform strain, demonstrate a direct relationship between AWG velocities and the square root of the AWG diameter. Consequently, it is reasoned that for a part with several embedded AWG, each of the same diameter, then differences in the AWG velocities would yield information on differences in the residual strain and moduli within the part.

  18. Comparison of Different Measurement Technologies for the In-Flight Assessment of Radiated Acoustic Intensity

    NASA Technical Reports Server (NTRS)

    Klos, Jacob; Palumbo, Daniel L.; Buehrle, Ralph D.; Williams, Earl G.; Valdivia, Nicolas; Herdic, Peter C.; Sklanka, Bernard

    2005-01-01

    A series of tests was planned and conducted in the Interior Noise Test Facility at Boeing Field, on the NASA Aries 757 flight research aircraft, and in the Structural Acoustic Loads and Transmission Facility at NASA Langley Research Center. These tests were designed to answer several questions concerning the use of array methods in flight. One focus of the tests was determining whether and to what extent array methods could be used to identify the effects of an acoustical treatment applied to a limited portion of an aircraft fuselage. Another focus of the tests was to verify that the arrays could be used to localize and quantify a known source purposely placed in front of the arrays. Thus the issues related to backside sources and flanking paths present in the complicated sound field were addressed during these tests. These issues were addressed through the use of reference transducers, both accelerometers mounted to the fuselage and microphones in the cabin, that were used to correlate the pressure holograms. measured by the microphone arrays using either SVD methods or partial coherence methods. This correlation analysis accepts only energy that is coherent with the sources sensed by the reference transducers, allowing a noise control engineer to only identify and study those vibratory sources of interest. The remainder of this paper will present a detailed description of the test setups that were used in this test sequence and typical results of the NAH/IBEM analysis used to reconstruct the sound fields. Also, a comparison of data obtained in the laboratory environments and during flights of the 757 aircraft will be made.

  19. Acoustic speed and attenuation coefficient in sheep aorta measured at 5-9 MHz.

    PubMed

    Fraser, Katharine H; Poepping, Tamie L; McNeilly, Alan; Megson, Ian L; Hoskins, Peter R

    2006-06-01

    B-mode ultrasound (US) images from blood vessels in vivo differ significantly from vascular flow phantom images. Phantoms with acoustic properties more closely matched to those of in vivo arteries may give better images. A method was developed for measuring the speed and attenuation coefficient of US over the range 5 to 9 MHz in samples of sheep aorta using a pulse-echo technique. The times-of-flight method was used with envelope functions to identify the reference points. The method was tested with samples of tissue-mimicking material of known acoustic properties. The tissue samples were stored in Krebs physiologic buffer solution and measured over a range of temperatures. At 37 degrees C, the acoustic speed and attenuation coefficient as a function of frequency in MHz were 1600 +/- 50 ms(-1) and 1.5 +/- 4f(0.94 +/- 1.3) dB cm(-1), respectively.

  20. Guidelines for Acoustical Measurements Inside Historical Opera Houses: Procedures and Validation

    NASA Astrophysics Data System (ADS)

    POMPOLI, ROBERTO; PRODI, NICOLA

    2000-04-01

    The acoustics of Italian historical theatres is to be regarded as a cultural heritage, which is to be preserved and studied. These actions are imperative for handing down the heritage to future generations and to avoid its loss. In this paper, the technical means for scientific quantification of the acoustical heritage are presented in the form of operative guidelines for acoustical measurements inside historical theatres. The document includes the advice of international experts and is being employed during an extended measurement campaign inside renaissance and baroque historical theatres. A relevant part of the paper deals with the experimental validation of the recommendations given in the guidelines, achieved by a dedicated test session inside the Municipal Theatre of Ferrara.

  1. Electron density measurement in gas discharge plasmas by optical and acoustic methods

    NASA Astrophysics Data System (ADS)

    Biagioni, A.; Anania, M. P.; Bellaveglia, M.; Chiadroni, E.; Cianchi, A.; Di Giovenale, D.; Di Pirro, G.; Ferrario, M.; Filippi, F.; Mostacci, A.; Pompili, R.; Shpakov, V.; Vaccarezza, C.; Villa, F.; Zigler, A.

    2016-08-01

    Plasma density represents a very important parameter for both laser wakefield and plasma wakefield acceleration, which use a gas-filled capillary plasma source. Several techniques can be used to measure the plasma density within a capillary discharge, which are mainly based on optical diagnostic methods, as for example the well-known spectroscopic method using the Stark broadening effect. In this work, we introduce a preliminary study on an alternative way to detect the plasma density, based on the shock waves produced by gas discharge in a capillary. Firstly, the measurements of the acoustic spectral content relative to the laser-induced plasmas by a solid target allowed us to understand the main properties of the acoustic waves produced during this kind of plasma generation; afterwards, we have extended such acoustic technique to the capillary plasma source in order to calibrate it by comparison with the stark broadening method.

  2. Monitoring Concrete Deterioration Due to Reinforcement Corrosion by Integrating Acoustic Emission and FBG Strain Measurements

    PubMed Central

    Li, Weijie; Xu, Changhang; Ho, Siu Chun Michael; Wang, Bo; Song, Gangbing

    2017-01-01

    Corrosion of concrete reinforcement members has been recognized as a predominant structural deterioration mechanism for steel reinforced concrete structures. Many corrosion detection techniques have been developed for reinforced concrete structures, but a dependable one is more than desired. Acoustic emission technique and fiber optic sensing have emerged as new tools in the field of structural health monitoring. In this paper, we present the results of an experimental investigation on corrosion monitoring of a steel reinforced mortar block through combined acoustic emission and fiber Bragg grating strain measurement. Constant current was applied to the mortar block in order to induce accelerated corrosion. The monitoring process has two aspects: corrosion initiation and crack propagation. Propagation of cracks can be captured through corresponding acoustic emission whereas the mortar expansion due to the generation of corrosion products will be monitored by fiber Bragg grating strain sensors. The results demonstrate that the acoustic emission sources comes from three different types, namely, evolution of hydrogen bubbles, generation of corrosion products and crack propagation. Their corresponding properties are also discussed. The results also show a good correlation between acoustic emission activity and expansive strain measured on the specimen surface. PMID:28327510

  3. Monitoring Concrete Deterioration Due to Reinforcement Corrosion by Integrating Acoustic Emission and FBG Strain Measurements.

    PubMed

    Li, Weijie; Xu, Changhang; Ho, Siu Chun Michael; Wang, Bo; Song, Gangbing

    2017-03-22

    Corrosion of concrete reinforcement members has been recognized as a predominant structural deterioration mechanism for steel reinforced concrete structures. Many corrosion detection techniques have been developed for reinforced concrete structures, but a dependable one is more than desired. Acoustic emission technique and fiber optic sensing have emerged as new tools in the field of structural health monitoring. In this paper, we present the results of an experimental investigation on corrosion monitoring of a steel reinforced mortar block through combined acoustic emission and fiber Bragg grating strain measurement. Constant current was applied to the mortar block in order to induce accelerated corrosion. The monitoring process has two aspects: corrosion initiation and crack propagation. Propagation of cracks can be captured through corresponding acoustic emission whereas the mortar expansion due to the generation of corrosion products will be monitored by fiber Bragg grating strain sensors. The results demonstrate that the acoustic emission sources comes from three different types, namely, evolution of hydrogen bubbles, generation of corrosion products and crack propagation. Their corresponding properties are also discussed. The results also show a good correlation between acoustic emission activity and expansive strain measured on the specimen surface.

  4. Radio acoustic measurement of temperature profile in the troposphere and stratosphere

    NASA Astrophysics Data System (ADS)

    Matuura, N.; Masuda, Y.; Inuki, H.; Kato, S.; Fukao, S.; Sato, T.; Tsuda, T.

    1986-10-01

    The radio acoustic sounding system (RASS) uses radar to measure the temperature profile in the atmosphere. In the standard technique of atmospheric radar, the radar backscatter results from electrical permittivity variations due to natural phenomena such as turbulence and precipitation. In the RASS technique, the radar backscatter results from periodical permittivity variations due to density/temperature variations imposed on the atmosphere by an acoustic wave artificially generated in such a way that the acoustic wavelength is half the radar (electromagnetic) wavelength. This `Bragg condition' is necessary for efficient backscattering. The backscatter echo of the RASS is affected by the Doppler frequency shift arising both from the speed at which the longitudinal acoustic perturbations propagate (the sound speed), and from the radial bulk velocity in the common volume of the atmosphere-the latter can be measured by the standard technique of turbulence scatter. The observed sound speed is reduced to give the local atmospheric temperature. Here we report an experiment using the RASS, carried out on 1-3 August 1985, which consisted of a high-power, very-high-frequency (VHF) Doppler radar at Shigaraki, Shiga, Japan and a movable high-power acoustic transmitter, and which gave the first experimental proof of the possibility of temperature profiling in the troposphere and stratosphere up to an altitude of ~20 km.

  5. Long Term Statistical Measurements of Environmental Acoustics Parameters in the Arctic. AEAS Report Number 2. Low Frequency Transmission Loss Measurements in the Central Arctic Ocean.

    DTIC Science & Technology

    2014-09-26

    RD-RI56 576 LONG TERM STATISTICAL MEASUREMENTS OF ENVIRONMENTAL 1/2 ACOUSTICS PRAMETERS I..(U) POLRR RESEARCH LAB INC CARPINTERIA CA B M BUCK 15 JAN...BUREAU Of STANDARDS-1963-A I l I E ".-.’ .’ In :j: Lona Term Statistical Measurements of Environmental Acoustics Parameters in the Arctic - AEAS...No - Lo Frequency Transmission ’>:--’.-’- , .- ’ ,. ’.*- Lona Term Statistical Measurements ofcean Environmental Acoustics Parameters ,..-’, in the

  6. Subjective evaluation of a concert hall's acoustics using a free-format-type questionnaire and comparison with objective measurements

    NASA Astrophysics Data System (ADS)

    Okano, Toshiyuki; Beranek, Leo L.

    2002-11-01

    A free-format type of audiences' judgment of the acoustical properties of a hall and music critics' writings were used as the basis for this study. These subjective responses are related to the Dai-Ichi Seimei Hall in Tokyo. This hall is an oval-shaped, one-balcony space, seating 767 persons. Its primary use is for various types of chamber music and solo-instrument performances. Eight acoustical attributes were investigated, ''reverberation,'' ''clarity,'' ''loudness,'' ''intimacy,'' ''spaciousness,'' ''balance,'' ''localization,'' and ''timbre,'' plus ''general impression.'' Subjective comments about these attributes were obtained. Objective measurements were made in the hall and are compared with those made in several similar-sized halls of two shapes. In the rear seats of two oval-shaped halls the strength factor GE (determined in the first 80 ms of the impulse response) was greater than the GE found in the rear seats of similar-sized rectangular halls. The subjective results and the objective measurements were closely correlated, especially for reverberation, clarity, and warmth (a subcomponent of timbre). It was suggested that the greater strength GE in the rear seats made the hall seem smaller and thus more intimate. The subjective comments also confirmed the hall's wide applicability, indicating that the acoustical characteristics used for its design were well chosen.

  7. Comparison of acoustic and conventional flow measurement techniques at the Raccoon Mountain Pumped-Storage Plant: Final report

    SciTech Connect

    March, P.A.; Missimer, J.R.; Voss, A.; Pearson, H.S.

    1987-08-01

    The Electric Power Research Institute (EPRI) initiated a research project to evaluate the technical and economic feasibility of using the acoustic method of flow measurement in hydroelectric power plant efficiency tests. As a portion of this program, the Tennessee Valley Authority's (TVA) Raccoon Mountain Pumped-Storage Plant was chosen as one of the sites to be tested. The primary objective of the TVA test was to compare the measurements of the Ocean Research Engineering (ORE), acoustic flowmeter installed on Unit 1 to the Volumetric and Winter-Kennedy Techniques for flow measurement. The Winter-Kennedy Technique is the standard flow measurement technique used in the plant. The Volumetric Technique consisted of accurate measurement of the upper reservoir volume over specified time increments. For calibration, the upper reservoir was initially drained and as it was being filled, aerial photographs were taken to obtain contour lines which were correlated with simultaneous stage measurements. The photographs were used to compute the differential volume of the reservoir associated with a change in stage. Six performance tests were conducted on Unit 1. During the tests no other units were operated. Five tests were conducted in the generating mode and one test was conducted in the pumping mode. The uncertainty in the measurements using the Volumetric Technique is of the order of 0.5 percent for changes of stage elevation in excess of two feet. The flowrate measured by the ORE acoustic flowmeter was consistently of the order of 1.5 percent lower than the flowrate determined from the Volumetric Technique in both the generating and pumping modes. 3 refs., 32 figs., 14 tabs.

  8. Measurement of the speed of sound in trabecular bone by using a time reversal acoustics focusing system

    NASA Astrophysics Data System (ADS)

    Lee, Kang Il; Choi, Bok Kyoung

    2014-10-01

    A new method for measuring the speed of sound (SOS) in trabecular bone by using a time reversal acoustics (TRA) focusing system was proposed and validated with measurements obtained by using the conventional pulse-transmission technique. The SOS measured in 14 bovine femoral trabecular bone samples by using the two methods was highly correlated each other, although the SOS measured by using the TRA focusing system was slightly lower by an average of 2.2 m/s. The SOS measured by using the two methods showed high correlation coefficients of r = 0.92 with the apparent bone density, consistent with the behavior in human trabecular bone in vitro. These results prove the efficacy of the new method based on the principle of TRA to measure the SOS in trabecular bone.

  9. Impulse source versus dodecahedral loudspeaker for measuring parameters derived from the impulse response in room acoustics.

    PubMed

    San Martín, Ricardo; Arana, Miguel; Machín, Jorge; Arregui, Abel

    2013-07-01

    This study investigates the performance of dodecahedral and impulse sources when measuring acoustic parameters in enclosures according to ISO 3382-1 [Acoustics-Measurement of room acoustic parameters. Part 1: Performance spaces (International Organization for Standardization, Geneva, Switzerland, 2009)]. In general, methods using speakers as a sound source are limited by their frequency response and directivity. On the other hand, getting impulse responses from impulse sources typically involves a lack of repeatability, and it is usually necessary to average several measurements for each position. Through experiments in different auditoriums that recreate typical situations in which the measurement standard is applied, it is found that using impulse sources leads to greater variation in the results, especially at low frequencies. However, this prevents subsequent dispersions due to variables that this technique does not require, such as the orientation of the emitting source. These dispersions may be relevant at high frequencies exceeding the established tolerance criteria for certain parameters. Finally, a new descriptor for dodecahedral sources reflecting the influence their lack of omnidirectionality produces on measuring acoustic parameters is proposed.

  10. A 14-year-long Measurement of the Convergence Rate of the Juan de Fuca and North America Plates Offshore Central Oregon using GPS-Acoustics

    NASA Astrophysics Data System (ADS)

    Chadwell, C. D.; Webb, S. C.; Nooner, S. L.

    2015-12-01

    The motion of the sea floor was measured at a 3000-m-deep site approximately 120 km offshore Central Oregon using the GPS-Acoustic technique in 2000, 2001, 2002, 2003 and 2014. The GPS-Acoustic derived motion relative to the interior of North America agrees with the geomagnetically-derived value within their measurement uncertainties. The time series from the early 2000's was resurrected using two new innovations. The first innovation, a permanent benchmark that has locating channels and mating pins, allows reoccupation of an established benchmark at any later date using an ROV to replace the transponder on the benchmark. The second innovation: an autonomous platform based on a Waveglider that carries a GPS navigated acoustic transponder interrogation system that is wave and solar powered. This enables measurements to be obtained over a GPSA site without requiring a large ship, greatly reducing the cost of a GPSA measurement. Combining data at this site with data from two other GPS-Acoustic seafloor sites on the Juan de Fuca plate, makes it possible to determine a present-day Euler Pole for the Juan de Fuca - North America plates using GPS-Acoustics seafloor geodesy.

  11. Acoustic measurements of F100-PW-100 engine operating in hush house NSN 4920-02-070-2721

    NASA Astrophysics Data System (ADS)

    Miller, V. R.; Plzak, G. A.; Chinn, J. M.

    1981-09-01

    The purpose of this test program was to measure the acoustic environment in the hush house facility located at Kelly AFB Texas during operation of the F100-PW-100 engine to ensure that engine structural acoustic design limits were not exceeded. The acoustic measurements showed that no sonic fatigue problems are anticipated with the F100-PW-100 engine structure during operation in the hush house. The measured acoustic levels were less than those measured in an existing F100-PW-100 engine wet-cooled noise suppressor, but were increased over that measured during operation on an open test stand. It was recommended that the acoustic load increases measured in this program should be specified in the structural design criteria for engines which will be subjected to hush house operation or defining requirements for associated equipment.

  12. Acoustic measurements of F-4E aircraft operating in hush house, NSN 4920-02-070-2721

    NASA Astrophysics Data System (ADS)

    Miller, V. R.; Plzak, G. A.; Chinn, J. M.

    1981-09-01

    The primary purpose of this test program was to measure the acoustic environment in the hush house facility located at Kelly Air Force Base, Texas, during operation of the F-4E aircraft to ensure that aircraft structural acoustic design limits were not exceeded. The acoustic measurements showed that sonic fatigue problems are anticipated with the F-4E aircraft aft fuselage structure during operation in the hush house. The measured acoustic levels were less than those measured in an F-4E aircraft water cooled hush house at Hill AFB in the lower frequencies, but were increased over that measured during ground run up on some areas of the aircraft. It was recommended that the acoustic loads measured in this program should be specified in the structural design criteria for aircraft which will be subjected to hush house operation or defining requirements for associated equipment. Recommendations were also made to increase the fatigue life of the aft fuselage.

  13. Measurement and Characterization of Space Shuttle Solid Rocket Motor Plume Acoustics

    NASA Technical Reports Server (NTRS)

    Kenny, Jeremy; Hobbs, Chris; Plotkin, Ken; Pilkey, Debbie

    2009-01-01

    Lift-off acoustic environments generated by the future Ares I launch vehicle are assessed by the NASA Marshall Space Flight Center (MSFC) acoustics team using several prediction tools. This acoustic environment is directly caused by the Ares I First Stage booster, powered by the five-segment Reusable Solid Rocket Motor (RSRMV). The RSRMV is a larger-thrust derivative design from the currently used Space Shuttle solid rocket motor, the Reusable Solid Rocket Motor (RSRM). Lift-off acoustics is an integral part of the composite launch vibration environment affecting the Ares launch vehicle and must be assessed to help generate hardware qualification levels and ensure structural integrity of the vehicle during launch and lift-off. Available prediction tools that use free field noise source spectrums as a starting point for generation of lift-off acoustic environments are described in the monograph NASA SP-8072: "Acoustic Loads Generated by the Propulsion System." This monograph uses a reference database for free field noise source spectrums which consist of subscale rocket motor firings, oriented in horizontal static configurations. The phrase "subscale" is appropriate, since the thrust levels of rockets in the reference database are orders of magnitude lower than the current design thrust for the Ares launch family. Thus, extrapolation is needed to extend the various reference curves to match Ares-scale acoustic levels. This extrapolation process yields a subsequent amount of uncertainty added upon the acoustic environment predictions. As the Ares launch vehicle design schedule progresses, it is important to take every opportunity to lower prediction uncertainty and subsequently increase prediction accuracy. Never before in NASA s history has plume acoustics been measured for large scale solid rocket motors. Approximately twice a year, the RSRM prime vendor, ATK Launch Systems, static fires an assembled RSRM motor in a horizontal configuration at their test facility

  14. Acoustic absorption measurement of human hair and skin within the audible frequency range.

    PubMed

    Katz, B F

    2000-11-01

    Utilizing the two-microphone impedance tube method, the acoustic absorption of human skin and hair is measured in the frequency range 1-6 kHz. Various locations on a number of human subjects are measured to determine if the presence of bone or an air pocket affects the acoustic absorption of human skin. The absorption coefficient of human hair is also measured. Additional techniques are utilized to minimize errors due to sample mounting methods. Techniques are employed to minimize potential errors in sensor and sample locations. The results of these measurements are compared to relevant historical papers on similar investigations. Results for skin measurements compare well with previous work. Measured hair absorption data do not agree with previous work in the area but do coincide with expected trends, which previous works do not.

  15. New design of the pulsed electro-acoustic upper electrode for space charge measurements during electronic irradiation.

    PubMed

    Riffaud, J; Griseri, V; Berquez, L

    2016-07-01

    The behaviour of space charges injected in irradiated dielectrics has been studied for many years for space industry applications. In our case, the pulsed electro-acoustic method is chosen in order to determine the spatial distribution of injected electrons. The feasibility of a ring-shaped electrode which will allow the measurements during irradiation is presented. In this paper, a computer simulation is made in order to determine the parameters to design the electrode and find its position above the sample. The obtained experimental results on polyethylene naphthalate samples realized during electronic irradiation and through relaxation under vacuum will be presented and discussed.

  16. New design of the pulsed electro-acoustic upper electrode for space charge measurements during electronic irradiation

    NASA Astrophysics Data System (ADS)

    Riffaud, J.; Griseri, V.; Berquez, L.

    2016-07-01

    The behaviour of space charges injected in irradiated dielectrics has been studied for many years for space industry applications. In our case, the pulsed electro-acoustic method is chosen in order to determine the spatial distribution of injected electrons. The feasibility of a ring-shaped electrode which will allow the measurements during irradiation is presented. In this paper, a computer simulation is made in order to determine the parameters to design the electrode and find its position above the sample. The obtained experimental results on polyethylene naphthalate samples realized during electronic irradiation and through relaxation under vacuum will be presented and discussed.

  17. Use of acoustic intensity measurements in the characterization of jet noise sources

    NASA Astrophysics Data System (ADS)

    Musafir, R. E.; Slama, J. G.; Zindeluk, M.

    The usefulness of two-microphone acoustic-intensity (AI) measurements for characterizing the acoustic field of a jet flow is investigated by means of numerical simulations. The theoretical principles and data basis for the simulations are explained, and the intensity patterns generated by the simulation are presented graphically. It is found that the vector information in AI data from the near field are useful in understanding complex sources, but that far-field intensity charts cannot locate separate sources and may be misleading if not analyzed in terms of a sound physical model.

  18. A Void Fraction Characterisation by Low Frequency Acoustic Velocity Measurements in Microbubble Clouds

    NASA Astrophysics Data System (ADS)

    Cavaro, Matthieu

    Low frequency acoustic velocity measurements have been applied for the characterization of microbubble clouds generated in water. This method, based on the Wood's model (1941) links the acoustic velocity throughout a two-phase medium to its void fraction value. Low frequency means below resonance frequencies of the bubbles inside the cloud. An original bench was developed to allow the qualification of this method. The experiments conducted allowed us to characterize void fraction values between 10-3 and 10-7. The radii of the studied microbubbles are between a few micrometers and a hundred micrometers.

  19. Molecular recognition in gas sensing: Results from acoustic wave and in-situ FTIR measurements

    SciTech Connect

    Hierlemann, A.; Ricco, A.J.; Bodenhoefer, K.; Goepel, W.

    1998-06-01

    Surface acoustic wave (SAW) measurements were combined with direct, in-situ molecular spectroscopy to understand the interactions of surface-confined sensing films with gas-phase analytes. This was accomplished by collecting Fourier-transform infrared external-reflectance spectra (FTIR-ERS) on operating SAW devices during dosing of their specifically coated surfaces with key analytes.

  20. A Multidimensional Investigation of Children's /r/ Productions: Perceptual, Ultrasound, and Acoustic Measures

    ERIC Educational Resources Information Center

    Klein, Harriet B.; McAllister Byun, Tara; Davidson, Lisa; Grigos, Maria I.

    2013-01-01

    Purpose: This study explored relationships among perceptual, ultrasound, and acoustic measurements of children's correct and misarticulated /r/ sounds. Longitudinal data documenting changes across these parameters were collected from 2 children who acquired /r/ over a period of intervention and were compared with data from children with typical…

  1. Effect of Foreshortening on Center-to-Limb Variations of Measured Acoustic Travel Times

    NASA Astrophysics Data System (ADS)

    Zhao, Junwei; Stejko, Andrey; Chen, Ruizhu

    2016-03-01

    We use data observed near the solar disk center by the Solar Dynamics Observatory/Helioseismic and Magnetic Imager (SDO/HMI) to mimic observations at high-latitude areas after applying geometric transform and projection. These data are then used to study how foreshortening affects the time-distance measurements of acoustic travel times. We find that foreshortening reduces the measured mean travel-times through altering the acoustic-power weighting in different harmonic degrees, but the level of reduction and the latitude dependence are not as strong as those measured from the observation data at the same latitude. Foreshortening is not found to be accountable for the systematic center-to-limb effect in the measured acoustic travel-time differences, which is an essential factor for a reliable inference of the Sun's meridional-circulation profile. The differences in the acoustic power spectrum between the mimicked data and the observation data in high-latitude areas suggest that the optical spectrum-line formation height or convection cells in these areas may be the primary cause of the center-to-limb effect in helioseismic analyses.

  2. An all fiber-optic sensor for surface acoustic wave measurements

    NASA Technical Reports Server (NTRS)

    Bowers, J. E.; Jungerman, R. L.; Khuri-Yakub, B. T.; Kino, G. S.

    1983-01-01

    A surface acoustic wave (SAW) sensor constructed from single-mode fiber-optic components is described. An analysis of reciprocal and nonreciprocal modes of operation of the sensor is presented. Results from measurements on a variety of SAW devices illustrate the use of the sensor. The amplitude sensitivity is 0.0003 A for an integration time of 0.1 s.

  3. Deriving content-specific measures of room acoustic perception using a binaural, nonlinear auditory model.

    PubMed

    van Dorp Schuitman, Jasper; de Vries, Diemer; Lindau, Alexander

    2013-03-01

    Acousticians generally assess the acoustic qualities of a concert hall or any other room using impulse response-based measures such as the reverberation time, clarity index, and others. These parameters are used to predict perceptual attributes related to the acoustic qualities of the room. Various studies show that these physical measures are not able to predict the related perceptual attributes sufficiently well under all circumstances. In particular, it has been shown that physical measures are dependent on the state of occupation, are prone to exaggerated spatial fluctuation, and suffer from lacking discrimination regarding the kind of acoustic stimulus being presented. Accordingly, this paper proposes a method for the derivation of signal-based measures aiming at predicting aspects of room acoustic perception from content specific signal representations produced by a binaural, nonlinear model of the human auditory system. Listening tests were performed to test the proposed auditory parameters for both speech and music. The results look promising; the parameters correlate with their corresponding perceptual attributes in most cases.

  4. Feasibility of using nonlinear guided waves to measure acoustic nonlinearity of aluminum

    NASA Astrophysics Data System (ADS)

    Matlack, Kathryn H.; Kim, Jin-Yeon; Jacobs, Laurence J.; Qu, Jianmin

    2011-04-01

    This research investigates the feasibility of measuring acoustic nonlinearity in aluminum with different ultrasonic guided wave modes. Acoustic nonlinearity is manifested by generation of a second harmonic component in an originally monochromatic ultrasonic wave signal, and previous research has shown this correlates to an intrinsic material property. This parameter has been shown to increase with accumulated material damage - specifically in low- and high-cycle fatigue - prior to crack initiation, whereas other ultrasonic nondestructive evaluation (NDE) techniques measuring linear parameters are unable to detect damage prior to crack initiation. In structural components such as jet engines and aircraft structures subjected to fatigue damage, crack initiation does not occur until ~80% of a component's life. Thus, there is a need for structural health monitoring (SHM) techniques that can characterize material damage state prior to crack initiation, and therefore nonlinear ultrasonic techniques have the potential to be powerful NDE and SHM tools. Experimental results using Rayleigh and Lamb guided wave modes to measure acoustic nonlinearity in undamaged aluminum 6061 samples are presented, and a comparison of the efficiency of these modes to measure acoustic nonlinearity is given.

  5. Acoustic sounder system design for measurement of optical turbulence and wind profiles

    NASA Astrophysics Data System (ADS)

    Miller, Judith E.; Eaton, Frank D.; Stokes, Sheldon S.

    2000-07-01

    An Acoustic Sounder System has been installed on the side of the cliff at North Oscura Peak, WSMR to provide important refractive index structure parameter, Cn2 data for laser propagation tests. The acoustic sounder system records echo information that is used to provide 3D wind and optical turbulence profiles. The received signal is the product of the interaction of the transmitted acoustic pulse with the small scale atmospheric temperature variations. This information is displayed as a time-height display of the signal intensity. The frequency of the received signals are processed and converted into time histories of the horizontal wind field. The data from the Acoustic Sounder is calibrated with the hot-wire anemometer temperature structure parameter (Ct2) data, and meteorological data measured locally to produce the Cn2 profile. The design and location of the Acoustic Sounder System will be discussed along with the methodology of extracting the turbulence. Many days of data have been collected and representative data will be shown.

  6. Acoustics Reflections of Full-Scale Rotor Noise Measurements in NFAC 40- by 80-Foot Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Barbely, Natasha Lydia; Kitaplioglu, Cahit; Sim, Ben W.

    2012-01-01

    The objective of current research is to identify the extent of acoustic time history distortions due to wind tunnel wall reflections. Acoustic measurements from the recent full-scale Boeing-SMART rotor test (Fig. 2) will be used to illustrate the quality of noise measurement in the NFAC 40- by 80-Foot Wind Tunnel test section. Results will be compared to PSU-WOPWOP predictions obtained with and without adjustments due to sound reflections off wind tunnel walls. Present research assumes a rectangular enclosure as shown in Fig. 3a. The Method of Mirror Images7 is used to account for reflection sources and their acoustic paths by introducing mirror images of the rotor (i.e. acoustic source), at each and every wall surface, to enforce a no-flow boundary condition at the position of the physical walls (Fig. 3b). While conventional approach evaluates the "combined" noise from both the source and image rotor at a single microphone position, an alternative approach is used to simplify implementation of PSU-WOPWOP for this reflection analysis. Here, an "equivalent" microphone position is defined with respect to the source rotor for each mirror image that effectively renders the reflection analysis to be a one rotor, multiple microphones problem. This alternative approach has the advantage of allowing each individual "equivalent" microphone, representing the reflection pulse from the associated wall surface, to be adjusted by the panel absorption coefficient illustrated in Fig. 1a. Note that the presence of parallel wall surfaces requires an infinite number of mirror images (Fig. 3c) to satisfy the no-flow boundary conditions. In the present analysis, up to four mirror images (per wall surface) are accounted to achieve convergence in the predicted time histories

  7. Evaluation of Acoustic Doppler Current Profiler measurements of river discharge

    USGS Publications Warehouse

    Morlock, S.E.

    1996-01-01

    The standard deviations of the ADCP measurements ranged from approximately 1 to 6 percent and were generally higher than the measurement errors predicted by error-propagation analysis of ADCP instrument performance. These error-prediction methods assume that the largest component of ADCP discharge measurement error is instrument related. The larger standard deviations indicate that substantial portions of measurement error may be attributable to sources unrelated to ADCP electronics or signal processing and are functions of the field environment.

  8. Acoustic signal propagation and measurement in natural stream channels for application to surrogate bed load measurements: Halfmoon Creek, Colorado

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Monitoring sediment-generated noise using submerged hydrophones is a surrogate method for measuring bed load transport in streams with the potential for improving estimates of bed load transport through widespread, inexpensive monitoring. Understanding acoustic signal propagation in natural stream e...

  9. Temporal acoustic measures distinguish primary progressive apraxia of speech from primary progressive aphasia.

    PubMed

    Duffy, Joseph R; Hanley, Holly; Utianski, Rene; Clark, Heather; Strand, Edythe; Josephs, Keith A; Whitwell, Jennifer L

    2017-02-07

    The purpose of this study was to determine if acoustic measures of duration and syllable rate during word and sentence repetition, and a measure of within-word lexical stress, distinguish speakers with primary progressive apraxia of speech (PPAOS) from nonapraxic speakers with the agrammatic or logopenic variants of primary progressive aphasia (PPA), and control speakers. Results revealed that the PPAOS group had longer durations and reduced rate of syllable production for most words and sentences, and the measure of lexical stress. Sensitivity and specificity indices for the PPAOS versus the other groups were highest for longer multisyllabic words and sentences. For the PPAOS group, correlations between acoustic measures and perceptual ratings of AOS were moderately high to high. Several temporal measures used in this study may aid differential diagnosis and help quantify features of PPAOS that are distinct from those associated with PPA in which AOS is not present.

  10. Method for extracting forward acoustic wave components from rotating microphone measurements in the inlets of turbofan engines

    NASA Technical Reports Server (NTRS)

    Cicon, D. E.; Sofrin, T. G.

    1995-01-01

    This report describes a procedure for enhancing the use of the basic rotating microphone system so as to determine the forward propagating mode components of the acoustic field in the inlet duct at the microphone plane in order to predict more accurate far-field radiation patterns. In addition, a modification was developed to obtain, from the same microphone readings, the forward acoustic modes generated at the fan face, which is generally some distance downstream of the microphone plane. Both these procedures employ computer-simulated calibrations of sound propagation in the inlet duct, based upon the current radiation code. These enhancement procedures were applied to previously obtained rotating microphone data for the 17-inch ADP fan. The forward mode components at the microphone plane were obtained and were used to compute corresponding far-field directivities. The second main task of the program involved finding the forward wave modes generated at the fan face in terms of the same total radial mode structure measured at the microphone plane. To obtain satisfactory results with the ADP geometry it was necessary to limit consideration to the propagating modes. Sensitivity studies were also conducted to establish guidelines for use in other fan configurations.

  11. Hydro-acoustic and tsunami waves generated by the 2012 Haida Gwaii earthquake: Modeling and in situ measurements

    NASA Astrophysics Data System (ADS)

    Abdolali, Ali; Cecioni, Claudia; Bellotti, Giorgio; Kirby, James T.

    2015-02-01

    Detection of low-frequency hydro-acoustic waves as precursor components of destructive tsunamis can enhance the promptness and the accuracy of Tsunami Early Warning Systems (TEWS). We reconstruct the hydro-acoustic wave field generated by the 2012 Haida Gwaii tsunamigenic earthquake using a 2-D horizontal numerical model based on the integration over the depth of the compressible fluid wave equation and considering a mild sloped rigid seabed. Spectral analysis of the wave field obtained at different water depths and distances from the source revealed the frequency range of low-frequency elastic oscillations of sea water. The resulting 2-D numerical model gave us the opportunity to study the hydro-acoustic wave propagation in a large-scale domain with available computers and to support the idea of deep-sea observatory and data interpretation. The model provides satisfactory results, compared with in situ measurements, in the reproduction of the long-gravitational waves. Differences between numerical results and field data are probably due to the lack of exact knowledge of sea bottom motion and to the rigid seabed approximation, indicating the need for further study of poro-elastic bottom effects.

  12. Measurement and mathematical simulation of acoustic characteristics of an artificially lengthened vocal tract

    NASA Astrophysics Data System (ADS)

    Radolf, Vojtěch; Horáček, Jaromír; Dlask, Pavel; Otčenášek, Zdeněk; Geneid, Ahmed; Laukkanen, Anne-Maria

    2016-03-01

    Phonation into tubes is used for voice training and therapy. In the present study, the formant frequencies were estimated from measurements of the acoustic pressure and the acoustic input impedance for a plexiglass model of the vocal tract (VT) prolonged by a glass tube. Similar transfer function measurements were performed with a human VT in vivo. The experimental results matched the mathematical modelling and confirmed the legitimacy of assuming rigid walls in mathematical simulations of the acoustic characteristics of an artificial VT model prolonged by a tube. However, this study also proved a considerable influence from soft tissues in the yielding walls of human VT cavities on the first formant frequency, F1. The measured F1 for the VT model corresponded to the computed value of 78 Hz. The experiments in a human instead resulted in a much higher value of F1: about 200 Hz. The results confirm that a VT model with yielding walls must be considered for mathematical modelling of the occluded or semi-occluded human vocal tract, e.g. prolonged by tubes or straws. This is explained by an acoustic-structural interaction of the vocal tract cavities with a mechanical low-frequency resonance of the soft tissue in the larynx.

  13. Acoustic-Seismic Coupling in Porous Ground - Measurements and Analysis for On-Site-Inspection Support

    NASA Astrophysics Data System (ADS)

    Liebsch, Mattes; Gorschlüter, Felix; Altmann, Jürgen

    2014-05-01

    During on-site inspections (OSI) of the Comprehensive Nuclear Test Ban Treaty Organisation (CTBTO) a local seismic network can be installed to measure seismic aftershock signals of an assumed underground nuclear explosion. These signals are caused by relaxation processes in and near the cavity created by the explosion and when detected can lead to a localisation of the cavity. This localisation is necessary to take gas samples from the ground which are analysed for radioactive noble gas isotopes to confirm or dismiss the suspicion of a nuclear test. The aftershock signals are of very low magnitude so they can be masked by different sources, in particular periodic disturbances caused by vehicles and aircraft in the inspection area. Vehicles and aircraft (mainly helicopters) will be used for the inspection activities themselves, e.g. for overhead imagery or magnetic-anomaly sensing. While vehicles in contact with the ground can excite soil vibrations directly, aircraft and vehicles alike emit acoustic waves which excite soil vibrations when hitting the ground. These disturbing signals are of periodic nature while the seismic aftershock signals are pulse-shaped, so their separation is possible. The understanding of the coupling of acoustic waves to the ground is yet incomplete, a better understanding is necessary to improve the performance of an OSI, e.g. to address potential consequences for the sensor placement, the helicopter trajectories etc. In a project funded by the Young Scientist Research Award of the CTBTO to one of us (ML), we investigated the acoustic-seismic coupling of airborne signals of jet aircraft and artificially induced ones by a speaker. During a measurement campaign several acoustic and seismic sensors were placed below the take-off trajectory of an airport at 4 km distance. Therefore taking off and landing jet aircraft passed nearly straightly above the setup. Microphones were placed close to the ground to record the sound pressure of incident

  14. Tethered acoustic doppler current profiler platforms for measuring streamflow

    USGS Publications Warehouse

    Rehmel, Michael S.; Stewart, James A.; Morlock, Scott E.

    2003-01-01

    A tethered-platform design with a trimaran hull and 900-megahertz radio modems is now commercially available. Continued field use has resulted in U.S. Geological Survey procedures for making tethered-platform discharge measurements, including methods for tethered-boat deployment, moving-bed tests, and measurement of edge distances.

  15. Dredging Research Program: Acoustic Resuspension Measurement System (ARMS) Instrumental Manual

    DTIC Science & Technology

    1994-06-01

    pounds (mass) 0.4535924 kilograms * To obtain Celsius (C) temperature readings from Fahrenheit ( F ) readings, use the following formula: C = (5/9) ( F ...32). To obtain kelvin (K) readings, use: K = (5/9) ( F - 32) + 273.15. x 1 Introduction The Dredging Research Program The Dredging Research Program...theory as Chapar 3 ARMS koumemdon 9 I(zjt) - N + F (Z’TP{ nQizt) 9i a’ 1 x exp(-) where N = intensity of additive noise F = response function of the

  16. Numerical and experimental investigation of a low-frequency measurement technique: differential acoustic resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Yin, Hanjun; Zhao, Jianguo; Tang, Genyang; Ma, Xiaoyi; Wang, Shangxu

    2016-06-01

    Differential acoustic resonance spectroscopy (DARS) has been developed to determine the elastic properties of saturated rocks within the kHz frequency range. This laboratory technique is based on considerations from perturbation theory, wherein the resonance frequencies of the resonant cavity with and without a perturbation sample are used to estimate the acoustic properties of the test sample. In order to better understand the operating mechanism of DARS and therefore optimize the procedure, it is important to develop an accurate and efficient numerical model. Accordingly, this study presents a new multiphysics model by coupling together considerations from acoustics, solid mechanics, and electrostatics. The numerical results reveal that the newly developed model can successfully simulate the acoustic pressure field at different resonance modes, and that it can accurately reflect the measurement process. Based on the understanding of the DARS system afforded by the numerical simulation, we refine the system configuration by utilizing cavities of different lengths and appropriate radii to broaden the frequency bandwidth and ensure testing accuracy. Four synthetic samples are measured to test the performance of the optimized DARS system, in conjunction with ultrasonic and static measurements. For nonporous samples, the estimated bulk moduli are shown to be independent of the different measurement methods (i.e. DARS or ultrasonic techniques). In contrast, for sealed porous samples, the differences in bulk moduli between the low- and high-frequency techniques can be clearly observed; this discrepancy is attributed to frequency dispersion. In summary, the optimized DARS system with an extended frequency range of 500-2000 Hz demonstrates considerable utility in investigating the frequency dependence of the acoustic properties of reservoir rocks.

  17. Advances in Fast-response Acoustically Derived Air-temperature Measurements

    NASA Astrophysics Data System (ADS)

    Bogoev, I.; Jacobsen, L.; Horst, T. W.; Conrad, B.

    2015-12-01

    Fast-response accurate air-temperature measurements are required when estimating turbulent fluxes of heat, water and carbon dioxide by open-path eddy-covariance technique. In comparison with contact thermometers like thermocouples, ultra-sonic thermometers do not suffer from solar radiation loading, water vapor condensation and evaporative cooling effects. Consequently they have the potential to provide more accurate true air temperature measurements. The absolute accuracy of the ultrasonic thermometer is limited by the following parameters: the distance between the transducer pairs, transducer delays associated with the electrical-acoustic signal conversion that vary with temperature, components of the wind vector that are normal to the ultrasonic paths, and humidity.The distance between the transducer pairs is commonly obtained by coordinate measuring machine. Improved accuracy demonstrated in this study results from increased stiffness in the anemometer head to better maintain the ultrasonic path-length distances. To further improve accuracy and account for changes in transducer delays and distance as a function of temperature, these parameters are characterized in a zero-wind chamber over the entire operating temperature range. When the sonic anemometer is combined with a co-located fast-response water vapor analyzer, like in the IRGASON instrument, speed of sound can be compensated for humidity effects on a point-by-point basis resulting in a true fast-response air temperature measurement. Laboratory test results show that when the above steps are implemented in the calibration of the ultrasonic thermometer air-temperature accuracy better than ±0.5 degrees Celsius can be achieved over the entire operating range. The approach is also validated in a field inter-comparison with an aspirated thermistor probe mounted in a radiation shield.

  18. Pressure transducer for measuring acoustic radiation force based on a magnetic sensor

    NASA Astrophysics Data System (ADS)

    Kamimura, H. A. S.; Pavan, T. Z.; Almeida, T. W. J.; Pádua, M. L. A.; Baggio, A. L.; Fatemi, M.; Carneiro, A. A. O.

    2011-01-01

    This work presents a pressure transducer based on a magnetic sensor to measure acoustic radiation force (ARF) and small displacements. The methodology presented in this paper allowed this transducer to be calibrated for use as an acoustic pressure and intensity meter. It can control the acoustic intensity emitted by ultrasound used, for example, in ARF impulse imaging, vibro-acoustography and high-intensity focused ultrasound techniques. The device comprises a magnet, a membrane, a magnetoresistive sensor and a coil to cancel the external magnetic field. When ARF is applied to the membrane, the magnetic field on the sensor changes due to the magnetic target displacement. The variation of the output signal from the magnetic transducer is proportional to the acoustic pressure applied to the membrane. A focused ultrasound transducer with a central frequency of 3 MHz was used to apply a continuous ARF. The sensitivities of the magnetic transducer as an acoustic pressure and intensity meter, evaluated in water, were respectively 0.597 µV MPa-1 and 0.073 µV (W cm-2)-1/2, while those of the needle hydrophone (Onda model HNP-0400) used in the magnetic transducer calibration were respectively, 0.5024 mV MPa-1 and 6.153 mV (W cm-2)-1/2. The transducer resolution to displacement is 5 nm and 6 dB of signal attenuation occurs for 7° of misalignment. The transducer responded well to acoustic pressure in water above 200 kPa.

  19. Surface acoustical intensity measurements on a diesel engine

    NASA Technical Reports Server (NTRS)

    Mcgary, M. C.; Crocker, M. J.

    1980-01-01

    The use of surface intensity measurements as an alternative to the conventional selective wrapping technique of noise source identification and ranking on diesel engines was investigated. A six cylinder, in line turbocharged, 350 horsepower diesel engine was used. Sound power was measured under anechoic conditions for eight separate parts of the engine at steady state operating conditions using the conventional technique. Sound power measurements were repeated on five separate parts of the engine using the surface intensity at the same steady state operating conditions. The results were compared by plotting sound power level against frequency and noise source rankings for the two methods.

  20. Optimization of Measurement Points Choice in Preparation of Green Areas Acoustic Map

    NASA Astrophysics Data System (ADS)

    Sztubecka, Małgorzata; Bujarkiewicz, Adam; Sztubecki, Jacek

    2016-12-01

    The aim of the article is to analyze the selection of measuring points of sustainable sound level in the spa park. A set of points should allow to make on their basis an acoustic climate map for the park at certain times of day by usage available tools. Practical part contains a comparative analysis of developed noise maps, taking into account different variants of the distribution and number of measuring points on the selected area of the park.

  1. Integration of acoustic radiation force and optical imaging for blood plasma clot stiffness measurement.

    PubMed

    Wang, Caroline W; Perez, Matthew J; Helmke, Brian P; Viola, Francesco; Lawrence, Michael B

    2015-01-01

    Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood's transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties.

  2. A novel instrument to measure acoustic resonances of the vocal tract during phonation

    NASA Astrophysics Data System (ADS)

    Epps, J.; Smith, J. R.; Wolfe, J.

    1997-10-01

    Acoustic resonances of the vocal tract give rise to formants (broad bands of acoustic power) in the speech signal when the vocal tract is excited by a periodic signal from the vocal folds. This paper reports a novel instrument which uses a real-time, non-invasive technique to measure these resonances accurately during phonation. A broadband acoustic current source is located just outside the mouth of the subject and the resulting acoustic pressure is measured near the lips. The contribution of the speech signal to the pressure spectrum is then digitally suppressed and the resonances are calculated from the input impedance of the vocal tract as a function of the frequency. The external excitation signal has a much smaller harmonic spacing than does the periodic signal from the vocal folds and consequently the resonances are determined much more accurately due to the closer sampling. This is particularly important for higher pitched voices and we demonstrate that this technique can be markedly superior to the curve-fitting technique of linear prediction. The superior frequency resolution of this instrument which results from external vocal tract excitation can provide the precise, stable, effective, articulatory feedback considered essential for some language-learning and speech-therapy applications.

  3. Integration of Acoustic Radiation Force and Optical Imaging for Blood Plasma Clot Stiffness Measurement

    PubMed Central

    Wang, Caroline W.; Perez, Matthew J.; Helmke, Brian P.; Viola, Francesco; Lawrence, Michael B.

    2015-01-01

    Despite the life-preserving function blood clotting serves in the body, inadequate or excessive blood clot stiffness has been associated with life-threatening diseases such as stroke, hemorrhage, and heart attack. The relationship between blood clot stiffness and vascular diseases underscores the importance of quantifying the magnitude and kinetics of blood’s transformation from a fluid to a viscoelastic solid. To measure blood plasma clot stiffness, we have developed a method that uses ultrasound acoustic radiation force (ARF) to induce micron-scaled displacements (1-500 μm) on microbeads suspended in blood plasma. The displacements were detected by optical microscopy and took place within a micro-liter sized clot region formed within a larger volume (2 mL sample) to minimize container surface effects. Modulation of the ultrasound generated acoustic radiation force allowed stiffness measurements to be made in blood plasma from before its gel point to the stage where it was a fully developed viscoelastic solid. A 0.5 wt % agarose hydrogel was 9.8-fold stiffer than the plasma (platelet-rich) clot at 1 h post-kaolin stimulus. The acoustic radiation force microbead method was sensitive to the presence of platelets and strength of coagulation stimulus. Platelet depletion reduced clot stiffness 6.9 fold relative to platelet rich plasma. The sensitivity of acoustic radiation force based stiffness assessment may allow for studying platelet regulation of both incipient and mature clot mechanical properties. PMID:26042775

  4. The acoustic environment of intensive care wards based on long period nocturnal measurements.

    PubMed

    Xie, Hui; Kang, Jian

    2012-01-01

    The patients in the Intensive Care Units are often exposed to excessive levels of noise and activities. They can suffer from sleep disturbance, especially at night, but they are often too ill to cope with the poor environment. This article investigates the acoustic environment of typical intensive care wards in the UK, based on long period nocturnal measurements, and examines the differences between singlebed and multibed wards, using statistical analysis. It has been shown that the acoustic environment differs significantly every night. There are also significant differences between the noise levels in the singlebed and multibed wards, where acoustic ceilings are present. Despite the similar background noises in both ward types, more intrusive noises tend to originate from the multibed wards, while more extreme sounds are likely to occur in the single wards. The sound levels in the measured wards for each night are in excess of the World Health Organization's (WHO) guide levels by at least 20 dBA, dominantly at the middle frequencies. Although the sound level at night varies less than that in the daytime, the nocturnal acoustic environment is not dependant on any specific time, thus neither the noisiest nor quietest period can be determined. It is expected that the statistical analysis of the collected data will provide essential information for the development of relevant guidelines and noise reduction strategies.

  5. Acoustic Measurements of Residual Stresses and Grain Sizes in Aluminum Alloys

    NASA Astrophysics Data System (ADS)

    Fisher, Martin John

    The theory of acoustoelasticity relates the velocity of an acoustic wave in a solid to the elastic stress state in that solid. This thesis presents new theories, measurement techniques, and methodologies related to the use of longitudinal wave acoustoelasticity in aluminum alloys. A one-dimensional model has been developed to provide a simple understanding of the acoustoelastic effect. A new acoustic device for accurately measuring relative thickness variations has been designed and built. This device is used--in conjunction with a pulse-echo phase measurement device and a computer controlled scanning system--to measure acoustic velocity variations in plastically deformed and non-flat-and-parallel samples. Acoustic velocity variations from point to point in an unstressed sample can sometimes be on the same order as velocity changes due to applied or residual stresses, and this can make stress measurements difficult. A statistical theory has been developed to relate these unstressed velocity variations to the average grain size in the sample and to the active area of the acoustic transducer used. Large transducers and small grain sizes will minimize these variations. This relationship has been verified by tests on a number of aluminum alloys and a new method for non-destructive grain size determination has been suggested. A systematic methodology has been developed and tested for studying the influence of uniaxial plastic deformation on the acoustoelastic response. Samples have been plastically deformed in four-point bending to produce elastic-plastic and residual stress states. Acoustic measurements of these stresses have then been compared directly to theoretical predictions based on the materials' stress-strain curves and simple beam theory. In the aluminum alloys tested (2024-T351 and 7075-T651), the acoustoelastic constants are shown to be virtually unchanged by uniaxial plastic strains of less than 2.5%. Thus, the acoustoelastic technique can be reliably

  6. Acoustic measurements through analysis of binaural recordings of speech and music

    NASA Astrophysics Data System (ADS)

    Griesinger, David

    2004-10-01

    This paper will present and demonstrate some recent work on the measurement of acoustic properties from binaural recordings of live performances. It is found that models of the process of stream formation can be used to measure intelligibility, and, when combined with band-limited running cross-correlation, can be used to measure spaciousness and envelopment. Analysis of the running cross correlation during sound onsets can be used to measure the accuracy of azimuth perception. It is additionally found that the ease of detecting fundamental pitch from the upper partials of speech and music can be used as a measure of sound quality, particularly for solo instruments and singers.

  7. Measurement of ultrasonic nonlinear parameter by using electromagnetic acoustic transducer

    NASA Astrophysics Data System (ADS)

    Cai, Zhichao; Liu, Suzhen; Zhang, Chuang

    2017-02-01

    The nonlinear ultrasonic technology is generally known as an effective method for the microcrack detection. However, most of the previous experimental studies were limited by a contact nonlinearity method. Since measurement by the contact method is affected by the coupling conditions, additional nonlinear coefficient are lead into the measurement. This research presents a novel technique for nonlinear ultrasonic wave measurements that uses a non-contact electromagnetic ultrasonic transducer (EMAT). And for a better understanding and a more in-depth analysis of the macroscopic nonlinear behavior of microcrack, the developed FEM modeling approach was built to simulate microcrack induced nonlinearities manifested in electromagnetic ultrasonic waves and validated experimentally. This study has yielded a quantitative characterization strategy for microcrack using EMAT, facilitating deployment of structural health monitoring by noncontact electromagnetic nondestructive testing.

  8. A Connection Model between the Positioning Mechanism and Ultrasonic Measurement System via a Web Browser to Assess Acoustic Target Strength

    NASA Astrophysics Data System (ADS)

    Ishii, Ken; Imaizumi, Tomohito; Abe, Koki; Takao, Yoshimi; Tamura, Shuko

    This paper details a network-controlled measurement system for use in fisheries engineering. The target strength (TS) of fish is important in order to convert acoustic integration values obtained during acoustic surveys into estimates of fish abundance. The target strength pattern is measured with the combination of the rotation system for the aspect of the sample and the echo data acquisition system using the underwater supersonic wave. The user interface of the network architecture is designed for collaborative use with researchers in other organizations. The flexible network architecture is based on the web direct-access model for the rotation mechanism. The user interface is available for monitoring and controlling via a web browser that is installed in any terminal PC (personal computer). Previously the combination of two applications was performed not by a web browser but by the exclusive interface program. So a connection model is proposed between two applications by indirect communication via the DCOM (Distributed Component Object Model) server and added in the web direct-access model. A prompt report system in the TS measurement system and a positioning and measurement system using an electric flatcar via a web browser are developed. By a secure network architecture, DCOM communications via both Intranet and LAN are successfully certificated.

  9. Accurate measurements of the acoustical physical constants of synthetic alpha-quartz for SAW devices.

    PubMed

    Kushibiki, Juin-ichi; Takanaga, Izumi; Nishiyama, Shouichi

    2002-01-01

    Accurate measurements of the acoustical physical constants (elastic constants, piezoelectric constants, dielectric constants, and density) of commercially available and widely used surface acoustic wave (SAW)-grade synthetic a-quartz are reported. The propagation directions and modes of bulk waves optimal for accurately determining the constants were selected through numerical calculations, and three principal X-, Y-, and Z-cut specimens and several rotated Y-cut specimens were prepared from a single crystal ingot to determine the constants and to confirm their accuracy. All of the constants were determined through highly accurate measurements of the longitudinal velocities, shear velocities, dielectric constants, and density. The velocity values measured for the specimens that were not used to determine the constants agreed well with those calculated from the determined constants, within a difference of +/- 0.20 m/s (+/- 0.004%).

  10. Developing a confocal acoustic holography microscope for non-invasive 3D temperature and composition measurements.

    PubMed

    Herring, Rodney A; Jacquemin, Peter; Sawicka, Barbara D; Atalick, Stefan

    2009-06-01

    A confocal acoustic holography microscope (CAHM) has been designed, simulated and partially verified experimentally to take holograms for non-invasive, three-dimensional measurements of a specimen's refractive indices from one view point. The designed and simulated prototype CAHM used a frequency of 2.25 MHz and measured sound speed changes of 16 m/s, temperature changes of 5 degrees C and had a spatial resolution of 660 microm. With future improvements utilizing the latest technologies such as two-dimensional array detectors, Micro-Electro-Mechanical Systems (MEMS), and acoustic lenses, resolutions of 1m/s, 0.5 degrees C, and 150 microm are expected. The CAHM is expected to have many useful applications, including non-invasive mass and heat transfer measurements in fluids and materials and as a medical diagnostic tool to non-intrusively visualize compositions and temperatures within the human body.

  11. Measurements of Acoustic Properties of Porous and Granular Materials and Application to Vibration Control

    NASA Technical Reports Server (NTRS)

    Park, Junhong; Palumbo, Daniel L.

    2004-01-01

    For application of porous and granular materials to vibro-acoustic controls, a finite dynamic strength of the solid component (frame) is an important design factor. The primary goal of this study was to investigate structural vibration damping through this frame wave propagation for various poroelastic materials. A measurement method to investigate the vibration characteristics of the frame was proposed. The measured properties were found to follow closely the characteristics of the viscoelastic materials - the dynamic modulus increased with frequency and the degree of the frequency dependence was determined by its loss factor. The dynamic stiffness of hollow cylindrical beams containing porous and granular materials as damping treatment was measured also. The data were used to extract the damping materials characteristics using the Rayleigh-Ritz method. The results suggested that the acoustic structure interaction between the frame and the structure enhances the dissipation of the vibration energy significantly.

  12. Acoustic input impedance of the avian inner ear measured in ostrich (Struthio camelus).

    PubMed

    Muyshondt, Pieter G G; Aerts, Peter; Dirckx, Joris J J

    2016-09-01

    In both mammals and birds, the mechanical behavior of the middle ear structures is affected by the mechanical impedance of the inner ear. In this study, the aim was to quantify the acoustic impedance of the avian inner ear in the ostrich, which allows us to determine the effect on columellar vibrations and middle ear power flow in future studies. To determine the inner ear impedance, vibrations of the columella were measured for both the quasi-static and acoustic stimulus frequencies. In the frequency range of 0.3-4 kHz, we used electromagnetic stimulation of the ossicle and a laser Doppler vibrometer to measure the vibration response. At low frequencies, harmonic displacements were imposed on the columella using piezo stimulation and the resulting force response was measured with a force sensor. From these measurement data, the acoustic impedance of the inner ear could be determined. A simple RLC model in series of the impedance measurements resulted in a stiffness reactance of KIE = 0.20·10(12) Pa/m³, an inertial impedance of MIE = 0.652·10(6) Pa s(2)/m³, and a resistance of RIE = 1.57·10(9) Pa s/m. We found that values of the inner ear impedance in the ostrich are one to two orders in magnitude smaller than what is found in mammal ears.

  13. In situ measurements of sediment acoustic properties in Currituck Sound and comparison to models.

    PubMed

    Lee, Kevin M; Ballard, Megan S; McNeese, Andrew R; Muir, Thomas G; Wilson, Preston S; Costley, R Daniel; Hathaway, Kent K

    2016-11-01

    In situ measurements of compressional and shear wave speed and attenuation were collected 30 cm below the water-sediment interface in Currituck Sound, North Carolina at two field locations having distinctly different sediment types: medium-to-fine-grained sand and fine-grained sand with approximately 10% mud content. Shear wave measurements were performed with bimorph transducers to generate and receive horizontally polarized shear waves in the 300 Hz to 1 kHz band, and compressional wave measurements were performed using hydrophones operated in the 5 kHz to 100 kHz band. Sediment samples were collected at both measurement sites and later analyzed in the laboratory to characterize the sediment grain size distribution for each field location. Compressional and shear wave speed and attenuation were estimated from the acoustic measurements, and preliminary comparisons to the extended Biot model by Chotiros and Isakson [J. Acoust. Soc. 135, 3264-3279 (2014)] and the viscous grain-shearing theory by Buckingham [J. Acoust. Soc. 136, 2478-2488 (2014)] were performed.

  14. The relationship between VHI scores and specific acoustic measures of mildly disordered voice production.

    PubMed

    Wheeler, Karen M; Collins, Savita P; Sapienza, Christine M

    2006-06-01

    This study was designed to examine the relationship between the Voice Handicap Index (VHI) and acoustic measures of voice samples common in clinical practice. Fifty participants, 38 women and 12 men, ranging in age from 19 to 80 years, with a mean age of 49 years, served as participants. Of these 50 participants, 17 participants could be included in the acoustic analysis of voice based on measures of error calculated with the TF32 software. All participants completed the VHI and provided voice samples including three trials of the sustained vowel /A/ at a comfortable loudness level as well as a connected speech sample consisting of the Zoo Passage. Acoustic measures were made with TF32 and Cool Edit software and included fundamental frequency, jitter %, shimmer %, signal-to-noise ratio, mean root-mean-square intensity, fundamental frequency standard deviation, aphonic periods, and breath groups. Results indicate that these measures were not predictive of overall VHI score, and no cohesive or predictable pattern was identified when comparing individual measures with overall VHI or with each subscale item. Likely contributions to this lack of correlation and subsequent clinical implications are discussed, as well as the direction for further research.

  15. Direct Measurements of Edge Diffraction from Soft Underwater Acoustic Panels

    DTIC Science & Technology

    1994-06-01

    kokmenna". SOd nMn de thub essifetos•’ an urde aspect of d0OW *81brde e ehn to Nevleee. 0’"t’rate fmr Infoem•Mdoun OPe-dohs end ReprSt. 1211 Jeffe.n. Sthe...finite sample- in Fi.9(b). The multiple internal contributions are ap- ae effects in transmitted-wave measurements made on multilayer un. derwater

  16. Measurement of Acoustic Attenuation and Absorption Coefficients using Thermometry

    NASA Astrophysics Data System (ADS)

    Morris, Hugh; Rivens, Ian; Shaw, Adam; ter Haar, Gail

    2007-05-01

    Accurate knowledge of both the attenuation and the absorption coefficient of tissue are required when planning an optimal high intensity focused ultrasound treatment. A novel technique for simple measurement of this parameters has been developed in which a thin-film thermocouple (TFT) is placed between two layers of tissue of different thicknesses. The sample can be rotated about an axis through the junction of the TFT so that it can be insonated from either side leaving the tissue adjacent to the junction unchanged, but changing the overlying thickness. The attenuation and absorption coefficients can be calculated from the heating curves measured in the two orientations. Experiments have been carried out in both tissue mimicking material (TMM) and in ex vivo liver tissue. Weakly focused transducers, resonant at 1.05 MHz, 2.4 MHz and 3.55 MHz were used at free-field spatial peak intensities of 9-14 W/cm2. The temperature rise was measured as a function of time using a TFT. These thermocouples are not subject to the viscous heating artefact that is common to other thermocouple devices and so are advantageous for this purpose. Alignment was achieved with a 3D automated gantry system, which was controlled with specialised software. Timing and data acquisition were also controlled with this software. All experiments were carried out in degassed water. Results for TMM and degassed excised bovine liver are presented.

  17. Age effects in the human middle ear: Wideband acoustical measures

    NASA Astrophysics Data System (ADS)

    Feeney, M. Patrick; Sanford, Chris A.

    2004-12-01

    Studies that have examined age effects in the human middle ear using either admittance measures at 220 or 660 Hz or multifrequency tympanometry from 200 to 2000 Hz have had conflicting results. Several studies have suggested an increase in admittance with age, while several others have suggested a decrease in admittance with age. A third group of studies found no significant age effect. This study examined 226 Hz tympanometry and wideband energy reflectance and impedance at ambient pressure in a group of 40 young adults and a group of 30 adults with age >=60 years. The groups did not differ in admittance measures of the middle ear at 226 Hz. However, significant age effects were found in wideband energy reflectance and impedance. In particular, in older adults there was a comparative decrease in reflectance from 800 to 2000 Hz but an increase near 4000 Hz. The results suggest a decrease in middle-ear stiffness with age. The findings of this study hold relevance for understanding the aging process in the auditory system, for the establishment of normative data for wideband energy reflectance, for the possibility of a conductive component to presbycusis, and for the interpretation of otoacoustic emission measurements. .

  18. Synthetic aperture acoustic measurements of stationary suspended cinderblock and surrogate substitutes

    NASA Astrophysics Data System (ADS)

    Bishop, Steven; Woods, Teresa; Vignola, Joe; Judge, John; Soumekh, Mehrdad

    2009-05-01

    A synthetic aperture acoustic approach is used as a standoff method to assess material properties of a typical cinder block, referred to as a concrete masonry unit (CMU), and a variety of CMU surrogates. The objective is to identify anomalies in CMU wall surfaces. The acoustic specular return and phase change across the blocks are the fundamental measurements of interest. The CMU surrogates are created from commercially available closed cell expanding foam. Results from three test articles are presented that show potentially exploitable differences in terms of acoustic magnitude and acoustic phase response between the surrogates and typical CMUs. The test articles are; a typical CMU, a foam block, and a foam block with an embedded steel object. All test articles are similar in size and shape, and both foam blocks are covered in grout so that surface appearance closely matches that of a CMU. The results show that each of the test articles has characteristics that may be used for discrimination and anomaly detection.

  19. High Frequency Acoustic Sensor Dedicated to the High Resolution Measurement of Mechanical Properties

    NASA Astrophysics Data System (ADS)

    Meignen, Pierre-Antoine; Le Clézio, Emmanuel; Despaux, Gilles

    Through acoustic signature, scanning acoustic microscopy can be used to quantify local mechanical properties of a medium thanks to the generation of surface waves, mostly Rayleigh waves. Despite being quite effective, this method requires to evaluate the mechanical properties of a single point the acquisition of many ultrasonic signals. This process is then time-consuming and is hardly adaptable to quantitative imaging. The solution considered in this paper to speed-up the method is to design a multi-element sensor allowing the extraction of information on Rayleigh waves with a reduced number of acquisitions. The work is conducted along two axes. As a first step, a model allowing the simulation of the acoustic wave behavior at a fluid/solid interface is developed. This model leads to a better understanding of the characterization of the mechanical properties and to the definition of an adapted sensor's design. As a second step, an experimental method for acoustic field reconstruction is used to characterize the multi-elements sensor and measurements of mechanical properties were done.

  20. Estimation of acoustical streaming: theoretical model, Doppler measurements and optical visualisation.

    PubMed

    Nowicki, A; Kowalewski, T; Secomski, W; Wójcik, J

    1998-02-01

    An approximate solution for the streaming velocity generated by flat and weakly focused transducers was derived by directly solving the Dirichlet boundary conditions for the Poisson equation, the solution of the Navier-Stokes equation for the axial components of the streaming velocity. The theoretical model was verified experimentally using a 32 MHz pulsed Doppler unit. The experimental acoustical fields were produced by three different 4 mm diameter flat and focused transducers driven by the transmitter generating the average acoustic power within the range from 1 microW to 6 mW. The streaming velocity was measured along the ultrasonic beam from 0 to 2 cm. Streaming was induced in a solution of water and corn starch. The experimental results showed that for a given acoustic power the streaming velocity was independent of the starch density in water, changed from 0.3 to 40 grams of starch in 1 l of distilled water. For applied acoustic powers, the streaming velocity changed linearly from 0.2 to 40 mm/s. Both, the theoretical solutions for plane and focused waves and the experimental results were in good agreement. The streaming velocity field was also visualised using the particle image velocimetry (PIV) and two different evaluation methods. The first based on the FFT-based cross-correlation analysis between small sections for each pair of images and the second employing the algorithm of searching for local displacements between several images.

  1. Development of an Acoustic Sensor On-Line Gas Temperature Measurement in Gasifiers

    SciTech Connect

    Peter Ariessohn

    2008-06-30

    This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-02NT41422 and specifically addresses Technical Topical Area 2 - Gasification Technologies. The project team includes Enertechnix, Inc. as the main contractor and ConocoPhillips Company as a technical partner, who also provides access to the SG Solutions Gasification Facility (formerly Wabash River Energy Limited), host for the field-testing portion of the research. The objective of this project was to adapt acoustic pyrometer technology to make it suitable for measuring gas temperature inside a coal gasifier, to develop a prototype sensor based on this technology, and to demonstrate its performance through testing on a commercial gasifier. The project was organized in three phases, each of approximately one year duration. The first phase consisted of researching a variety of sound generation and coupling approaches suitable for use with a high pressure process, evaluation of the impact of gas composition variability on the acoustic temperature measurement approach, evaluation of the impact of suspended particles and gas properties on sound attenuation, evaluation of slagging issues and development of concepts to deal with this issue, development and testing of key prototype components to allow selection of the best approaches, and development of a conceptual design for a field prototype sensor that could be tested on an operating gasifier. The second phase consisted of designing and fabricating a series of prototype sensors, testing them in the laboratory, and developing a conceptual design for a field prototype sensor. The third phase consisted of designing and fabricating the field prototype, and testing it in the lab and in a commercial gasifier to demonstrate the ability to obtain accurate measurements of gas temperature in an operating gasifier. Following the completion of the initial 3 year project, several continuations

  2. Acoustic Resuspension Measurement System (ARMS): Announcement of Availability.

    DTIC Science & Technology

    1992-04-01

    their controlling circuitry to be con,- Z bined in compact, battery -powered packages. These instrument packages can W 0 be contained in rellatively... Station DTIO QUALITY [INSP8•ECTE"•D 4 3909 Halls Ferry Road. Vicksburg, MS 39180-6199 tzqq o- ,1TEDOf’ rYCjA" PiosJ Mr. E. Clark McNair, Jr., (601... Prickett and Michelle M. Thevenot. Introduction In order to measure in situ properties of the boundary layer above dredged material mounds in open

  3. Non-Destructive Evaluation Method and Apparatus for Measuring Acoustic Material Nonlinearity

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H. (Inventor)

    2002-01-01

    An acoustic non-linearity parameter (beta) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members obviates the need for electronic calibration of the measuring equipment. Unlike known substitutional measuring techniques requiring elaborate calibration procedures, the electrical outputs of the capacitive detector of a sample with known beta and the test sample of unknown beta are compared to determine the unknown beta. In order to provide the necessary stability of the present-inventive reference-based approach, the bandpass filters of the measurement system are maintained in a temperature-controlled environment, and the line voltage supplied to said amplifiers is well-regulated.

  4. Sub-Microsecond Temperature Measurement in Liquid Water Using Laser Induced Thermal Acoustics

    NASA Technical Reports Server (NTRS)

    Alderfer, David W.; Herring, G. C.; Danehy, Paul M.; Mizukaki, Toshiharu; Takayama, Kazuyoshi

    2005-01-01

    Using laser-induced thermal acoustics, we demonstrate non-intrusive and remote sound speed and temperature measurements over the range 10 - 45 C in liquid water. Averaged accuracy of sound speed and temperature measurements (10 s) are 0.64 m/s and 0.45 C respectively. Single-shot precisions based on one standard deviation of 100 or greater samples range from 1 m/s to 16.5 m/s and 0.3 C to 9.5 C for sound speed and temperature measurements respectively. The time resolution of each single-shot measurement was 300 nsec.

  5. Acoustic Experiment to Measure the Bulk Viscosity of Near-Critical Xenon in Microgravity

    NASA Technical Reports Server (NTRS)

    Gillis, K. A.; Shinder, I.; Moldover, M. R.; Zimmerli, G. A.

    2002-01-01

    We plan a rigorous test of the theory of dynamic scaling by accurately measuring the bulk viscosity of xenon in microgravity 50 times closer to the critical temperature T(sub c) than previous experiments. The bulk viscosity zeta (or "second viscosity" or "dilational viscosity") will be determined by measuring the attenuation length of sound alpha lambda and also measuring the frequency-dependence of the speed of sound. For these measurements, we developed a unique Helmholtz resonator and specialized electro-acoustic transducers. We describe the resonator, the transducers, their performance on Earth, and their expected performance in microgravity.

  6. Brillouin-scattering measurements of the acoustic absorption coefficient in liquid CS2

    NASA Technical Reports Server (NTRS)

    Coakley, R. W.; Detenbeck, R. W.

    1975-01-01

    High-resolution Brillouin spectra were recorded for light scattered at small angles from liquid CS2. The use of a single-mode He-Ne laser, locked in frequency to a Fabry-Perot interferometer, permitted measurements of line widths of the order of 10 MHz for frequencies in the range 300-1000 MHz. These measurements extend previous Brillouin line-width measurements at higher frequencies into the region where relaxation effects are dominant and connect the optical measurements with lower-frequency acoustical data.

  7. Shallow-water acoustic tomography from angle measurements instead of travel-time measurements.

    PubMed

    Aulanier, Florian; Nicolas, Barbara; Mars, Jérôme I; Roux, Philippe; Brossier, Romain

    2013-10-01

    For shallow-water waveguides and mid-frequency broadband acoustic signals, ocean acoustic tomography (OAT) is based on the multi-path aspect of wave propagation. Using arrays in emission and reception and advanced array processing, every acoustic arrival can be isolated and matched to an eigenray that is defined not only by its travel time but also by its launch and reception angles. Classically, OAT uses travel-time variations to retrieve sound-speed perturbations; this assumes very accurate source-to-receiver clock synchronization. This letter uses numerical simulations to demonstrate that launch-and-reception-angle tomography gives similar results to travel-time tomography without the same requirement for high-precision synchronization.

  8. River habitat quality from river velocities measured using acoustic Doppler current profiler.

    PubMed

    Shields, F Douglas; Rigby, J R

    2005-10-01

    Prior research has demonstrated the utility of metrics based on spatial velocity gradients to characterize and describe stream habitat, with higher gradients generally indicative of higher levels of physical heterogeneity and thus habitat quality. However, detailed velocity data needed to compute these metrics are difficult to obtain. Acoustic Doppler current profilers (ADCP) may be used to rapidly collect detailed representations of river velocity fields. Herein we demonstrate use of ADCP to obtain ecologically relevant data and compute associated metrics. Data were collected from four reaches of the Little Tallahatchie River in northern Mississippi. Sampled reaches were selected to observe velocity regimes associated with three distinctly different conditions: downstream from a major flow obstruction (a low weir), downstream from the apices of each of two bends, and within an extremely long, straight reach created by channelization. Three-dimensional velocity data sets from each site were used to compute metrics of habitat quality proposed by others. A habitat metric based on the presence of rotational flow in the vertical plane proved to be the best discriminator among conditions within the sampled reaches. Two of four habitat quality metrics computed from these measured velocities were greatest for the sharpest meander bend. ADCP hold great potential for study of riverine physical aquatic habitats, particularly at the reach scale. Additional work is needed to develop generally applicable field protocols and data reduction tools. Specifically, guidelines for ADCP settings and configuration appropriate for a range of riverine site conditions must be developed. Advances in instrumentation are needed to allow collection of information in closer proximity to the free surface and solid boundaries.

  9. Overview of hydro-acoustic current-measurement applications by the U.S. geological survey in Indiana

    USGS Publications Warehouse

    Morlock, Scott E.; Stewart, James A.

    1999-01-01

    The U.S. Geological Survey (USGS) maintains a network of 170 streamflow-gaging stations in Indiana to collect data from which continuous records of river discharges are produced. Traditionally, the discharge record from a station is produced by recording river stage and making periodic discharge measurements through a range of stage, then developing a relation between stage and discharge. Techniques that promise to increase data collection accuracy and efficiency include the use of hydro-acoustic instrumentation to measure river velocities. The velocity measurements are used to compute river discharge. In-situ applications of hydro-acoustic instruments by the USGS in Indiana include acoustic velocity meters (AVM's) at six streamflow-gaging stations and newly developed Doppler velocity meters (DVM's) at two stations. AVM's use reciprocal travel times of acoustic signals to measure average water velocities along acoustic paths, whereas DVM's use the Doppler shift of backscattered acoustic signals to compute water velocities. In addition to the in-situ applications, three acoustic Doppler current profilers (ADCP's) are used to make river-discharge measurements from moving boats at streamflow-gaging stations in Indiana. The USGS has designed and is testing an innovative unmanned platform from which to make ADCP discharge measurements.

  10. In-situ optical and acoustical measurements of the buoyant cyanobacterium p. Rubescens: spatial and temporal distribution patterns.

    PubMed

    Hofmann, Hilmar; Peeters, Frank

    2013-01-01

    Optical (fluorescence) and acoustic in-situ techniques were tested in their ability to measure the spatial and temporal distribution of plankton in freshwater ecosystems with special emphasis on the harmful and buoyant cyanobacterium P. rubescens. Fluorescence was measured with the multi-spectral FluoroProbe (Moldaenke FluoroProbe, MFP) and a Seapoint Chlorophyll Fluorometer (SCF). In-situ measurements of the acoustic backscatter strength (ABS) were conducted with three different acoustic devices covering multiple acoustic frequencies (614 kHz ADCP, 2 MHz ADP, and 6 MHz ADV). The MFP provides a fast and reliable technique to measure fluorescence at different wavelengths in situ, which allows discriminating between P. rubescens and other phytoplankton species. All three acoustic devices are sensitive to P. rubescens even if other scatterers, e.g., zooplankton or suspended sediment, are present in the water column, because P. rubescens containing gas vesicles has a strong density difference and hence acoustic contrast to the ambient water and other scatterers. After calibration, the combination of optical and acoustical measurements not only allows qualitative and quantitative observation of P. rubescens, but also distinction between P. rubescens, other phytoplankton, and zooplankton. As the measuring devices can sample in situ at high rates they enable assessment of plankton distributions at high temporal (minutes) and spatial (decimeters) resolution or covering large temporal (seasonal) and spatial (basin scale) scales.

  11. Measurements of acoustic particle velocity in a coaxial duct and its application to a traveling-wave thermoacoustic heat engine

    NASA Astrophysics Data System (ADS)

    Morii, Jun; Biwa, Tetsushi; Yazaki, Taichi

    2014-09-01

    We present theoretical solutions, based on linear acoustic theory, for axial acoustic particle velocity in an annular region of a coaxial duct. The solutions are expressed in terms of two non-dimensional parameters h/δν and R; h and δν, respectively, represent the half of the spacing between two concentric ducts and the characteristic length given by kinematic viscosity of the gas and angular frequency of acoustic oscillations, and R is the radius ratio of the ducts. The validity of the solutions was verified by direct measurements using a laser Doppler velocimeter. The present results are applied to measurements of the acoustic power distribution in a traveling wave thermoacoustic engine with a coaxial duct, which provides experimental evidence for acoustic power feedback in the coaxial duct.

  12. Measurements of acoustic particle velocity in a coaxial duct and its application to a traveling-wave thermoacoustic heat engine.

    PubMed

    Morii, Jun; Biwa, Tetsushi; Yazaki, Taichi

    2014-09-01

    We present theoretical solutions, based on linear acoustic theory, for axial acoustic particle velocity in an annular region of a coaxial duct. The solutions are expressed in terms of two non-dimensional parameters h/δ(ν) and R; h and δ(ν), respectively, represent the half of the spacing between two concentric ducts and the characteristic length given by kinematic viscosity of the gas and angular frequency of acoustic oscillations, and R is the radius ratio of the ducts. The validity of the solutions was verified by direct measurements using a laser Doppler velocimeter. The present results are applied to measurements of the acoustic power distribution in a traveling wave thermoacoustic engine with a coaxial duct, which provides experimental evidence for acoustic power feedback in the coaxial duct.

  13. Measurement of Turbulence with Acoustic Doppler Current Profilers - Sources of Error and Laboratory Results

    USGS Publications Warehouse

    Nystrom, E.A.; Oberg, K.A.; Rehmann, C.R.; ,

    2002-01-01

    Acoustic Doppler current profilers (ADCPs) provide a promising method for measuring surface-water turbulence because they can provide data from a large spatial range in a relatively short time with relative ease. Some potential sources of errors in turbulence measurements made with ADCPs include inaccuracy of Doppler-shift measurements, poor temporal and spatial measurement resolution, and inaccuracy of multi-dimensional velocities resolved from one-dimensional velocities measured at separate locations. Results from laboratory measurements of mean velocity and turbulence statistics made with two pulse-coherent ADCPs in 0.87 meters of water are used to illustrate several of inherent sources of error in ADCP turbulence measurements. Results show that processing algorithms and beam configurations have important effects on turbulence measurements. ADCPs can provide reasonable estimates of many turbulence parameters; however, the accuracy of turbulence measurements made with commercially available ADCPs is often poor in comparison to standard measurement techniques.

  14. Microscopic imaging of residual stress using a scanning phase-measuring acoustic microscope

    NASA Astrophysics Data System (ADS)

    Meeks, Steven W.; Peter, D.; Horne, D.; Young, K.; Novotny, V.

    1989-10-01

    A high-resolution scanning phase-measuring acoustic microscope (SPAM) has been developed and used to image the near-surface residual stress field around features etched in sputtered alumina via the acoustoelastic effect. This microscope operates at 670 MHz and has a resolution of 5-10 microns, depending upon the amount of defocus. Relative velocity changes of sample surface waves as small as 50 ppm are resolved. Images of the stress field at the tip of a 400-micron-wide slot etched in alumina are presented and compared with a finite element simulation. The SPAM uses an unconventional acoustic lens with an anisotropic illumination pattern which can measure anisotropic effects and map residual stress fields with several-micron resolution and a stress sensitivity of 1/3 MPa in an alumina film.

  15. MEASUREMENTS OF THE WAVEFUNCTIONS OF SOLAR ACOUSTIC WAVES SCATTERED BY SUNSPOTS

    SciTech Connect

    Zhao Hui; Chou, Dean-Yi; Yang, Ming-Hsu

    2011-10-20

    Solar acoustic waves are scattered by sunspots because of the interaction between the acoustic waves and sunspots. We use a deconvolution scheme to obtain the wavefunction of the acoustic wave on the solar surface at various times from cross-correlation functions computed between an incident wave and the signals at other points on the surface. The wavefunction of the scattered wave is obtained by subtracting the wavefunction of the incident wave from that of the total wave. We study the wavefunctions of scattered waves with the incident waves of radial order n = 0-5 for two sunspots, NOAAs 11084 and 11092. The scattered wave is predominant in the forward direction of the incident wave, but its wavefronts are curved. The shape of the wavefronts depends on the ratio of sunspot dimension to wavelength of the incident wave. The smaller the ratio is, the closer to circular the scattered wave is. The scattering strength, i.e. the magnitude of the scattered wave relative to that of the incident wave, decreases with the radial order n. This suggests that the region generating the scattered wave is shallower than the depth of the f-modes.

  16. Discharge measurements using a broad-band acoustic Doppler current profiler

    USGS Publications Warehouse

    Simpson, Michael R.

    2002-01-01

    The measurement of unsteady or tidally affected flow has been a problem faced by hydrologists for many years. Dynamic discharge conditions impose an unreasonably short time constraint on conventional current-meter discharge-measurement methods, which typically last a minimum of 1 hour. Tidally affected discharge can change more than 100 percent during a 10-minute period. Over the years, the U.S. Geological Survey (USGS) has developed moving-boat discharge-measurement techniques that are much faster but less accurate than conventional methods. For a bibliography of conventional moving-boat publications, see Simpson and Oltmann (1993, page 17). The advent of the acoustic Doppler current profiler (ADCP) made possible the development of a discharge-measurement system capable of more accurately measuring unsteady or tidally affected flow. In most cases, an ADCP discharge-measurement system is dramatically faster than conventional discharge-measurement systems, and has comparable or better accuracy. In many cases, an ADCP discharge-measurement system is the only choice for use at a particular measurement site. ADCP systems are not yet ?turnkey;? they are still under development, and for proper operation, require a significant amount of operator training. Not only must the operator have a rudimentary knowledge of acoustic physics, but also a working knowledge of ADCP operation, the manufacturer's discharge-measurement software, and boating techniques and safety.

  17. Development of explicit diffraction corrections for absolute measurements of acoustic nonlinearity parameters in the quasilinear regime.

    PubMed

    Jeong, Hyunjo; Zhang, Shuzeng; Cho, Sungjong; Li, Xiongbing

    2016-08-01

    In absolute measurements of acoustic nonlinearity parameters, amplitudes of harmonics must be corrected for diffraction effects. In this study, we develop explicit multi-Gaussian beam (MGB) model-based diffraction corrections for the first three harmonics in weakly nonlinear, axisymmetric sound beams. The effects of making diffraction corrections on nonlinearity parameter estimation are investigated by defining "total diffraction correction (TDC)". The results demonstrate that TDC cannot be neglected even for harmonic generation experiments in the nearfield region.

  18. Breath air measurement using wide-band frequency tuning IR laser photo-acoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Kistenev, Yury V.; Borisov, Alexey V.; Kuzmin, Dmitry A.; Bulanova, Anna A.; Boyko, Andrey A.; Kostyukova, Nadezhda Y.; Karapuzikov, Alexey A.

    2016-03-01

    The results of measuring of biomarkers in breath air of patients with broncho-pulmonary diseases using wide-band frequency tuning IR laser photo-acoustic spectroscopy and the methods of data mining are presented. We will discuss experimental equipment and various methods of intellectual analysis of the experimental spectra in context of above task. The work was carried out with partial financial support of the FCPIR contract No 14.578.21.0082 (ID RFMEFI57814X0082).

  19. Granular Shear Zone Formation: Acoustic Emission Measurements and Fiber-bundle Models

    NASA Astrophysics Data System (ADS)

    Michlmayr, Gernot; Or, Dani

    2013-04-01

    We couple the acoustic emissions method with conceptual models of granular material behavior for investigation of granular shear zone formation and to assess eminence of landslide hazard. When granular materials are mechanically loaded or sheared, they tend to produce discrete events of force network restructuring, and frictional interaction at grain contacts. Such abrupt perturbations within the granular lattice release part of the elastic energy stored in the strained material. Elastic waves generated by such events can be measured as acoustic emissions (AE) and may be used as surrogates for intermittent structural transitions associated with shear zone formation. To experimentally investigate the connection between granular shearing and acoustic signals we performed an array of strain-controlled shear-frame tests using glass beads. AE were measured with two different systems operating at two frequency ranges. High temporal resolution measurements of the shear stresses revealed the presence of small fluctuations typically associated with low-frequency (< 20 kHz) acoustic bursts. Shear stress jumps and linked acoustic signals give account of discrete events of grain network rearrangements and obey characteristic exponential frequency-size distributions. We found that statistical features of force jumps and AE events depend on mechanical boundary conditions and evolve during the straining process. Activity characteristics of high-frequency (> 30 kHz) AE events is linked to friction between grains. To interpret failure associated AE signals, we adapted a conceptual fiber-bundle model (FBM) that describes some of the salient statistical features of failure and associated energy production. Using FBMs for the abrupt mechanical response of the granular medium and an associated grain and force chain AE generation model provides us with a full description of the mechanical-acoustical granular shearing process. Highly resolved AE may serve as a diagnostic tool not only

  20. The Application of Acoustic Measurements and Audio Recordings for Diagnosis of In-Flight Hardware Anomalies

    NASA Technical Reports Server (NTRS)

    Welsh, David; Denham, Samuel; Allen, Christopher

    2011-01-01

    In many cases, an initial symptom of hardware malfunction is unusual or unexpected acoustic noise. Many industries such as automotive, heating and air conditioning, and petro-chemical processing use noise and vibration data along with rotating machinery analysis techniques to identify noise sources and correct hardware defects. The NASA/Johnson Space Center Acoustics Office monitors the acoustic environment of the International Space Station (ISS) through periodic sound level measurement surveys. Trending of the sound level measurement survey results can identify in-flight hardware anomalies. The crew of the ISS also serves as a "detection tool" in identifying unusual hardware noises; in these cases the spectral analysis of audio recordings made on orbit can be used to identify hardware defects that are related to rotating components such as fans, pumps, and compressors. In this paper, three examples of the use of sound level measurements and audio recordings for the diagnosis of in-flight hardware anomalies are discussed: identification of blocked inter-module ventilation (IMV) ducts, diagnosis of abnormal ISS Crew Quarters rack exhaust fan noise, and the identification and replacement of a defective flywheel assembly in the Treadmill with Vibration Isolation (TVIS) hardware. In each of these examples, crew time was saved by identifying the off nominal component or condition that existed and in directing in-flight maintenance activities to address and correct each of these problems.

  1. Acoustical measurements of DOE/NASA MOD-0 wind turbine at Plum Brook Station, Ohio

    SciTech Connect

    Etter, C.L.; Kelley, N.D.; McKenna, H.E.; Linn, C.; Garrelts, R.

    1983-06-01

    This report documents the evaluation of low-frequency acoustic emissions associated with the operation of the DOE/NASA MOD-0 wind turbine generator located at Plum Brook Station, Ohio. These measurements were taken as part of a joint SERI/NASA Brook Station, Ohio. These measurements were taken as part of a joint SERI/NASA effort to study acoustic noise generation by utility-sized wind turbines. The machine-operating conditions closely simulated the operation of the larger DOE/NASA MOD-1 wind turbine installed near Boone, NC, in both its design downwind configuration and theoretical upwind mode. Measurement results indicated that acoustic impulses characteristic of the MOD-1 turbine were detectable only with a downwind configuration and a 35-rpm rotor speed, a situation which parallels a 23-rpm rotor speed operation on the MOD-1. Under the available meteorological conditions, no impulses were detected during downwind 23 rpm or by wind-induced noise, indicating a severe limitation of the microphone configuration used in these tests.

  2. Design and Instrumentation of a Measurement and Calibration System for an Acoustic Telemetry System

    SciTech Connect

    Deng, Zhiqun; Weiland, Mark A.; Carlson, Thomas J.; Eppard, M. B.

    2010-03-31

    The Juvenile Salmon Acoustic Telemetry System (JSATS) is an active sensing technology developed by Portland District, the U.S. Army Corps of Engineers for detecting and tracking small fish. It is used at hydroelectric projects and in the laboratory for evaluating behavior and survival of juvenile salmonids migrating through the Federal Columbia River Power System to the Pacific Ocean. It provides critical data for salmon protection and development of more “fish-friendly” hydroelectric facilities. The objective of this study was to design and build a measurement and calibration system for evaluating the JSATS component, because the JSATS requires comprehensive acceptance and performance testing in a controlled environment before it is deployed in the field. The system consists of a reference transducer, a water test tank lined with anechoic material, a motion control unit, a reference receiver, a signal conditioner and amplifier unit, a data acquisition board, MATLAB control and analysis interface, and a computer. The fully integrated system has been evaluated successfully at various simulated distances and using different encoded signals at frequencies within the bandwidth of the JSATS transmitter. It provides accurate acoustic mapping capability in a controlled environment and automates the process that allows real-time measurements and evaluation of the piezoelectric transducers, sensors, or the acoustic fields. The measurement and calibration system has been in use since 2009 for acceptance and performance testing of, and further improvements to, the JSATS.

  3. Complete velocity distribution in river cross-sections measured by acoustic instruments

    USGS Publications Warehouse

    Cheng, R.T.; Gartner, J.W.; ,

    2003-01-01

    To fully understand the hydraulic properties of natural rivers, velocity distribution in the river cross-section should be studied in detail. The measurement task is not straightforward because there is not an instrument that can measure the velocity distribution covering the entire cross-section. Particularly, the velocities in regions near the free surface and in the bottom boundary layer are difficult to measure, and yet the velocity properties in these regions play the most significant role in characterizing the hydraulic properties. To further characterize river hydraulics, two acoustic instruments, namely, an acoustic Doppler current profiler (ADCP), and a "BoogieDopp" (BD) were used on fixed platforms to measure the detailed velocity profiles across the river. Typically, 20 to 25 stations were used to represent a river cross-section. At each station, water velocity profiles were measured independently and/or concurrently by an ADCP and a BD. The measured velocity properties were compared and used in computation of river discharge. In a tow-tank evaluation of a BD, it has been confirmed that BD is capable of measuring water velocity at about 11 cm below the free-surface. Therefore, the surface velocity distribution across the river was extracted from the BD velocity measurements and used to compute the river discharge. These detailed velocity profiles and the composite velocity distribution were used to assess the validity of the classic theories of velocity distributions, conventional river discharge measurement methods, and for estimates of channel bottom roughness.

  4. Measuring discharge with acoustic Doppler current profilers from a moving boat

    USGS Publications Warehouse

    Mueller, David S.; Wagner, Chad R.; Rehmel, Michael S.; Oberg, Kevin A.; Rainville, Francois

    2013-01-01

    The use of acoustic Doppler current profilers (ADCPs) from a moving boat is now a commonly used method for measuring streamflow. The technology and methods for making ADCP-based discharge measurements are different from the technology and methods used to make traditional discharge measurements with mechanical meters. Although the ADCP is a valuable tool for measuring streamflow, it is only accurate when used with appropriate techniques. This report presents guidance on the use of ADCPs for measuring streamflow; this guidance is based on the experience of U.S. Geological Survey employees and published reports, papers, and memorandums of the U.S. Geological Survey. The guidance is presented in a logical progression, from predeployment planning, to field data collection, and finally to post processing of the collected data. Acoustic Doppler technology and the instruments currently (2013) available also are discussed to highlight the advantages and limitations of the technology. More in-depth, technical explanations of how an ADCP measures streamflow and what to do when measuring in moving-bed conditions are presented in the appendixes. ADCP users need to know the proper procedures for measuring discharge from a moving boat and why those procedures are required, so that when the user encounters unusual field conditions, the procedures can be adapted without sacrificing the accuracy of the streamflow-measurement data.

  5. [Absorbed dose conversion factors obtained from X-ray spectra measured at water phantom surface].

    PubMed

    Aoki, Kiyoshi; Koyama, Masaki

    2005-03-20

    The absorbed dose conversion factor for X-rays at the water phantom surface has been obtained from the measured spectra. These measurements have been made at tube voltages of 60 kV to 120 kV and field sizes ranging from 5 x 5 cm(2) to 30 x 30 cm(2) with and without additional 2 mm aluminium filtration. A small silicon diode detector with little angular dependence was used for this measurement. The absorbed dose conversion factor obtained was 0.03-0.43% smaller than that obtained from the primary X-ray spectrum. The difference was large for high-voltage and heavily filtered X-rays. As field size increases, the conversion factor decreases, but the decrease is slight when field size exceeds 20 x 20 cm(2). The absorbed dose conversion factor obtained from the primary or surface X-ray spectrum is 0.4-1.8% larger than that obtained from the effective energy of primary X-rays. The difference is large in high-voltage X-rays and decreases slightly with increases in field size.

  6. Obtaining Heat Stress Measurements. Module 15. Vocational Education Training in Environmental Health Sciences.

    ERIC Educational Resources Information Center

    Consumer Dynamics Inc., Rockville, MD.

    This module, one of 25 on vocational education training for careers in environmental health occupations, contains self-instructional materials on obtaining heat stress measurements. Following guidelines for students and instructors and an introduction that explains what the student will learn are three lessons: (1) naming and describing the…

  7. Liquid mercury sound velocity measurements under high pressure and high temperature by picosecond acoustics in a diamond anvils cell.

    PubMed

    Decremps, F; Belliard, L; Couzinet, B; Vincent, S; Munsch, P; Le Marchand, G; Perrin, B

    2009-07-01

    Recent improvements to measure ultrasonic sound velocities of liquids under extreme conditions are described. Principle and feasibility of picosecond acoustics in liquids embedded in a diamond anvils cell are given. To illustrate the capability of these advances in the sound velocity measurement technique, original high pressure and high temperature results on the sound velocity of liquid mercury up to 5 GPa and 575 K are given. This high pressure technique will certainly be useful in several fundamental and applied problems in physics and many other fields such as geophysics, nonlinear acoustics, underwater sound, petrology or physical acoustics.

  8. Method and apparatus for measuring surface changes, in porous materials, using multiple differently-configured acoustic sensors

    DOEpatents

    Hietala, Susan Leslie; Hietala, Vincent Mark; Tigges, Chris Phillip

    2001-01-01

    A method and apparatus for measuring surface changes, such as mass uptake at various pressures, in a thin-film material, in particular porous membranes, using multiple differently-configured acoustic sensors.

  9. Evaluation of stage acoustics in Seoul Arts Center Concert Hall by measuring stage support.

    PubMed

    Jeon, Jin Yong; Barron, Michael

    2005-01-01

    Stage acoustics is an important characteristic for concert halls, both for the acoustic quality on stage and for the audience. However, relatively little research has been conducted into the question. This study was based on the investigation of an actual concert hall stage, that of the Seoul Arts Center Concert Hall in Korea. The stage acoustics was evaluated in the actual hall, and with two models: a 1:25 scale model and a computer model. The study was based on the stage support parameter ST1 proposed by Gade as a measure of support for individual performers [Acustica 65, 193-203 (1989)]. The variation of support was measured on the empty stage of the actual hall and in the two models. The effect of musicians on stage, the effect of moving the orchestra, the effect of ceiling height and of stage-wall profile were also investigated. Conclusions are drawn both relating to the Seoul Concert Hall stage and stages in general.

  10. Acoustic measurements for the combustion diagnosis of diesel engines fuelled with biodiesels

    NASA Astrophysics Data System (ADS)

    Zhen, Dong; Wang, Tie; Gu, Fengshou; Tesfa, Belachew; Ball, Andrew

    2013-05-01

    In this paper, an experimental investigation was carried out on the combustion process of a compression ignition (CI) engine running with biodiesel blends under steady state operating conditions. The effects of biodiesel on the combustion process and engine dynamics were analysed for non-intrusive combustion diagnosis based on a four-cylinder, four-stroke, direct injection and turbocharged diesel engine. The signals of vibration, acoustic and in-cylinder pressure were measured simultaneously to find their inter-connection for diagnostic feature extraction. It was found that the sound energy level increases with the increase of engine load and speed, and the sound characteristics are closely correlated with the variation of in-cylinder pressure and combustion process. The continuous wavelet transform (CWT) was employed to analyse the non-stationary nature of engine noise in a higher frequency range. Before the wavelet analysis, time synchronous average (TSA) was used to enhance the signal-to-noise ratio (SNR) of the acoustic signal by suppressing the components which are asynchronous. Based on the root mean square (RMS) values of CWT coefficients, the effects of biodiesel fractions and operating conditions (speed and load) on combustion process and engine dynamics were investigated. The result leads to the potential of airborne acoustic measurements and analysis for engine condition monitoring and fuel quality evaluation.

  11. Rotating rake design for unique measurement of fan-generated spinning acoustic modes

    NASA Technical Reports Server (NTRS)

    Konno, Kevin E.; Hausmann, Clifford R.

    1993-01-01

    In light of the current emphasis on noise reduction in subsonic aircraft design, NASA has been actively studying the source of and propagation of noise generated by subsonic fan engines. NASA/LeRC has developed and tested a unique method of accurately measuring these spinning acoustic modes generated by an experimental fan. This mode measuring method is based on the use of a rotating microphone rake. Testing was conducted in the 9 x 15 Low-speed Wind Tunnel. The rotating rake was tested with the Advanced Ducted Propeller (ADP) model. This memorandum discusses the design and performance of the motor/drive system for the fan-synchronized rotating acoustic rake. This novel motor/drive design approach is now being adapted for additional acoustic mode studies in new test rigs as baseline data for the future design of active noise control for subsonic fan engines. Included in this memorandum are the research requirements, motor/drive specifications, test performance results, and a description of the controls and software involved.

  12. Design and instrumentation of a measurement and calibration system for an acoustic telemetry system.

    PubMed

    Deng, Zhiqun; Weiland, Mark; Carlson, Thomas; Eppard, M Brad

    2010-01-01

    The Juvenile Salmon Acoustic Telemetry System (JSATS) is an active sensing technology developed by the U.S. Army Corps of Engineers, Portland District, for detecting and tracking small fish. It is used primarily for evaluating behavior and survival of juvenile salmonids migrating through the Federal Columbia River Power System to the Pacific Ocean. It provides critical data for salmon protection and development of more "fish-friendly" hydroelectric facilities. The objective of this study was to design and build a Measurement and Calibration System (MCS) for evaluating the JSATS components, because the JSATS requires comprehensive acceptance and performance testing in a controlled environment before it is deployed in the field. The MCS consists of a reference transducer, a water test tank lined with anechoic material, a motion control unit, a reference receiver, a signal conditioner and amplifier unit, a data acquisition board, MATLAB control and analysis interface, and a computer. The fully integrated MCS has been evaluated successfully at various simulated distances and using different encoded signals at frequencies within the bandwidth of the JSATS transmitter. The MCS provides accurate acoustic mapping capability in a controlled environment and automates the process that allows real-time measurements and evaluation of the piezoelectric transducers, sensors, or the acoustic fields. The MCS has been in use since 2009 for acceptance and performance testing of, and further improvements to, the JSATS.

  13. Acoustic harmonic generation measurement applications: Detection of tight cracks in powder metallurgy compacts

    NASA Astrophysics Data System (ADS)

    Barnard, D. J.; Foley, J. C.

    2000-05-01

    Standard linear ultrasonic testing techniques have long been employed for locating and characterizing relatively open cracks in a wide variety of materials, from metallic alloys and ceramics to composites. In all these materials, the detection of open cracks easily accomplished because the void between the two crack surfaces provides sufficient acoustic impedance mismatch to reflect the incident energy. Closed or partially closed cracks, however, may often go undetected because contacting interfaces allow transmission of ultrasound. In the green (unsintered) state, powder metallurgy compacts typically contain high residual stresses that have the ability to close cracks formed during the compaction process, a result of oxide films, improper powder lubricant, mold design, etc. After sintering, the reduction of residual stresses may no longer be sufficient to close the crack. Although the crack may be more easily detected, it is obvious most desirable to discover defects prior to sintering. It has been shown that the displacements of an interface may be highly nonlinear if a stress wave of sufficient intensity propagates across it, a result of the stress wave either opening or closing the interface. Current efforts involve the application of nonlinear acoustic techniques, in particular acoustic harmonic generation measurements, for the detection and characterization of tightly closed cracks in powder metallurgy parts. A description of the equipment and the measurement technique will be discussed and initial experimental results on sintered and green compacts will be presented.—This work was performed at the Ames Laboratory, Iowa State University under USDOE Contract No. W-7405-ENG-82.

  14. A Tool Measuring Remaining Thickness of Notched Acoustic Cavities in Primary Reaction Control Thruster NDI Standards

    NASA Technical Reports Server (NTRS)

    Sun, Yushi; Sun, Changhong; Zhu, Harry; Wincheski, Buzz

    2006-01-01

    Stress corrosion cracking in the relief radius area of a space shuttle primary reaction control thruster is an issue of concern. The current approach for monitoring of potential crack growth is nondestructive inspection (NDI) of remaining thickness (RT) to the acoustic cavities using an eddy current or remote field eddy current probe. EDM manufacturers have difficulty in providing accurate RT calibration standards. Significant error in the RT values of NDI calibration standards could lead to a mistaken judgment of cracking condition of a thruster under inspection. A tool based on eddy current principle has been developed to measure the RT at each acoustic cavity of a calibration standard in order to validate that the standard meets the sample design criteria.

  15. Measurements of Finite Dust Temperature Effects in the Dispersion Relation of the Dust Acoustic Wave

    NASA Astrophysics Data System (ADS)

    Snipes, Erica; Williams, Jeremiah

    2009-04-01

    A dusty plasma is a four-component system composed of ions, electrons, neutral particles and charged microparticles. The presence of these charged microparticles gives rise to new plasma wave modes, including the dust acoustic wave. Recent measurements [1, 2] of the dispersion relationship for the dust acoustic wave in a glow discharge have shown that finite temperature effects are observed at higher values of neutral pressure. Other work [3] has shown that these effects are not observed at lower values of neutral pressure. We present the results of ongoing work examining finite temperature effects in the dispersion relation as a function of neutral pressure. [4pt] [1] E. Thomas, Jr., R. Fisher, and R. L. Merlino, Phys. Plasmas 14, 123701 (2007). [0pt] [2] J. D. Williams, E. Thomas Jr., and L. Marcus, Phys. Plasmas 15, 043704 (2008). [0pt] [3] T. Trottenberg, D. Block, and A. Piel, Phys. Plasmas 13, 042105 (2006).

  16. 3D flame topography obtained by tomographic chemiluminescence with direct comparison to planar Mie scattering measurements.

    PubMed

    Xu, Wenjiang; Wickersham, A J; Wu, Yue; He, Fan; Ma, Lin

    2015-03-20

    This work reports the measurements of 3D flame topography using tomographic chemiluminescence and its validation by direct comparison against planar Mie scattering measurements. Tomographic measurements of the 3D topography of various well-controlled laboratory flames were performed using projections measured by seven cameras, and a simultaneous Mie scattering measurement was performed to measure a 2D cross section of the 3D flame topography. The tomographic measurements were based on chemiluminescence emissions from the flame, and the Mie scattering measurements were based on micrometer-size oil droplets seeded into the flow. The flame topography derived from the 3D tomographic and the Mie scattering measurement was then directly compared. The results show that the flame topography obtained from tomographic chemiluminescence and the Mie measurement agreed qualitatively (i.e., both methods yielded the same profile of the flame fronts), but a quantitative difference on the order of millimeters was observed between these two methods. These results are expected to be useful for understanding the capabilities and limitations of the 3D tomographic and Mie scattering techniques in combustion diagnostics.

  17. Acoustic measurements of a full-scale coaxial hingeless rotor helicopter

    NASA Technical Reports Server (NTRS)

    Peterson, R. L.; Mosher, M.

    1983-01-01

    Acoustic data were obtained during a full-scale test of the XH-59A Advancing Blade Concept Technology Demonstrator in the 40- by 80-Foot Wind Tunnel. The XH-59A is a research helicopter with two coaxial rotors and hingeless blades. Performance, vibration, and noise at various forward speeds, rotor lift coefficients and rotor shaft angles of attack were investigated. The noise data were acquired over an isolated rotor lift coefficient range of 0.024 to 0.162, an advance ratio range of 0.23 to 0.45 corresponding to tunnel wind speeds of 89 to 160 knots, and angles of attack from 0 deg to 10 deg. Acoustic data are presented for seven microphone locations for all run conditions where the model noise is above the background noise. Model test configuration and performance information are also listed. Acoustic waveforms, dBA, and 1/3-octave spectra as functions of operating condition for selected data points and microphones are presented. In general, the noise level is shown to increase with rotor lift coefficient except under certain operating conditions where significant impulsive blade/vortex interactions increase noise levels.

  18. A noncontacting method for measuring sheet grammage and thickness using acoustic pulse techniques

    NASA Astrophysics Data System (ADS)

    Vuohelainen, Reijo Antero

    A new way to use an acoustic pulse transmission method to measure the basis weight and the thickness of paper and other thin materials was developed. The apparatus consisted of a sound source, a microphone, a digital oscilloscope, and a microcomputer. A short acoustic tone burst is transmitted through the sample and the transmission loss is defined as the ratio of the receiver voltage amplitude measured with the sample present to the voltage amplitude measured without the sample. This attenuation is a function of the basis weight of the sample and of the frequency used in the measurement. Different types of paper and plastic foils were measured with good accuracy. The measurement frequencies vary from 5 kHz to 40 kHz depending on the sample parameters. With the optimum frequency for the specific sample the accuracy is about +/-1% and the resolution is 0.5% of the grammage of the sample. This system can be used to measure both transparent and opaque foils, which makes it useful for many industrial and laboratory applications.

  19. In situ acoustic and laboratory ultrasonic sound speed and attenuation measured in heterogeneous soft seabed sediments: Eel River shelf, California

    USGS Publications Warehouse

    Gorgas, T.J.; Wilkens, R.H.; Fu, S.S.; Neil, Frazer L.; Richardson, M.D.; Briggs, K.B.; Lee, H.

    2002-01-01

    We compared in situ and laboratory velocity and attenuation values measured in seafloor sediments from the shallow water delta of the Eel River, California. This region receives a substantial volume of fluvial sediment that is discharged annually onto the shelf. Additionally, a high input of fluvial sediments during storms generates flood deposits that are characterized by thin beds of variable grain-sizes between the 40- and 90-m isobaths. The main objectives of this study were (1) to investigate signatures of seafloor processes on geoacoustic and physical properties, and (2) to evaluate differences between geoacoustic parameters measured in situ at acoustic (7.5 kHz) and in the laboratory at ultrasonic (400 kHz) frequencies. The in situ acoustic measurements were conducted between 60 and 100 m of water depth. Wet-bulk density and porosity profiles were obtained to 1.15 m below seafloor (m bsf) using gravity cores of the mostly cohesive fine-grained sediments across- and along-shelf. Physical and geoacoustic properties from six selected sites obtained on the Eel margin revealed the following. (1) Sound speed and wet-bulk density strongly correlated in most cases. (2) Sediment compaction with depth generally led to increased sound speed and density, while porosity and in situ attenuation values decreased. (3) Sound speed was higher in coarser- than in finer-grained sediments, on a maximum average by 80 m s-1. (4) In coarse-grained sediments sound speed was higher in the laboratory (1560 m s-1) than in situ (1520 m s-1). In contrast, average ultrasonic and in situ sound speed in fine-grained sediments showed only little differences (both approximately 1480 m s-1). (5) Greater attenuation was commonly measured in the laboratory (0.4 and 0.8 dB m-1 kHz-1) than in situ (0.02 and 0.65 dB m-1 kHz-1), and remained almost constant below 0.4 m bsf. We attributed discrepancies between laboratory ultrasonic and in situ acoustic measurements to a frequency dependence of

  20. [Obtaining the phage mini-antibodies and their use for detection of microbial cells by using an electro-acoustic sensor].

    PubMed

    Guliĭ, O I; Zaĭtsev, B D; Kuznetsova, I E; Shikhabudinov, A M; Karavaeva, O A; Dykman, L A; Staroverov, S A; Ignatov, O V

    2012-01-01

    The phage mini-antibodies to bacterial cells of strain Azospirillum brasilense Sp245 were obtained and the possibility of using them for detection of microbial cells by means of a lateral field excited piezoelectric resonator was studied. It has been found that the frequency dependencies of the real and imaginary parts of the electrical impedance of the resonator loaded by the cell suspension A. brasilense Sp245 with the mini-antibodies, significantly differ from those of the resonator with the control cell suspension without mini-antibodies. The concentration limit of possible determination of the microbial cells in their interaction with the mini-antibodies is equal to 10(3) cells/ml. It has been ascertained that detection of A. brasilense Sp245 cells using the mini-antibodies is possible even in the presence of other cultures, for example, E. coli BL-Ril and A. brasilense Sp7 cells. Therefore, it has been shown for the first time that detection of microbial cells by an electro-acoustic sensor is feasible.

  1. Tensile strain measurements of ceramic fibers using scanning laser acoustic microscopy

    NASA Astrophysics Data System (ADS)

    Kent, Renee M.; Vary, Alex

    1992-08-01

    A noncontacting technique using scanning laser acoustic microscopy for making in situ tensile strain measurements of small diameter fibers was implemented for the tensile strain analysis of individual Nicalon SiC fibers (nominal diameter 15 microns). Stress vs strain curves for the fibers were plotted from the experimental data. The mean elastic modulus of the fibers was determined to be 185.3 GPa. Similar measurements were made for Carborundum SiC fibers (nominal diameter 28 microns) and Saphikon sapphire fibers (nominal diameter 140 microns).

  2. Acoustical measurements of vibrational relaxation in moist N2 at elevated temperatures

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.; Meredith, R. W.

    1982-01-01

    Sound absorption measurements are conducted by the resonant tube technique to study vibrational relaxation in moist N2 at 301, 343, and 387 K. Analysis of the data shows that improved measurement accuracy at the higher temperatures establishes vibrational-vibrational energy transfer as the operative relaxation path for the de-excitation of N2 by H2O beyond the uncertainty of experimental error. The best-fitted temperature dependence of the vibrational-vibrational rate constant is given, noting that the expression is consistent with seven independent sets of both acoustical and nonacoustical data.

  3. Pressure Measurement in Supersonic Air Flow by Differential Absorptive Laser-Induced Thermal Acoustics

    NASA Technical Reports Server (NTRS)

    Hart, Roger C.; Herring, Gregory C.; Balla, Robert J.

    2007-01-01

    Nonintrusive, off-body flow barometry in Mach-2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, stream-wise velocity and static gas temperature of the same spatially-resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.

  4. Pressure measurement in supersonic air flow by differential absorptive laser-induced thermal acoustics.

    PubMed

    Hart, Roger C; Herring, G C; Balla, R Jeffrey

    2007-06-15

    Nonintrusive, off-body flow barometry in Mach 2 airflow has been demonstrated in a large-scale supersonic wind tunnel using seedless laser-induced thermal acoustics (LITA). The static pressure of the gas flow is determined with a novel differential absorption measurement of the ultrasonic sound produced by the LITA pump process. Simultaneously, the streamwise velocity and static gas temperature of the same spatially resolved sample volume were measured with this nonresonant time-averaged LITA technique. Mach number, temperature, and pressure have 0.2%, 0.4%, and 4% rms agreement, respectively, in comparison with known free-stream conditions.

  5. Using the Time-Lagged Function of Dual-Aperture Scintillometer Measurements to Obtain the Crosswind

    NASA Astrophysics Data System (ADS)

    van Dinther, D.; Hartogensis, O.

    2013-12-01

    In this study the so-called crosswind (U⊥), the wind component perpendicular on a path, is determined from scintillometer measurements. A scintillometer is a device consisting of a transmitter and receiver, typically spaced a few hundred meters to a few kilometers apart. The dual-aperture scintillometer used in this study consists of two transmitters and two receivers installed next to each other. The transmitters emit light with a certain intensity which is refracted by the eddies in the atmosphere. The eddy field in between the transmitters and receivers constantly changes leading to intensity fluctuations of the light at the receivers side, which gives the scintillometer signal. The driving phenomenon of the changing eddy field is wind. The scintillometer path is ~ 100 m and the spacing in between the apertures is ~ 10 cm therefore the eddy field is mainly changed due to U⊥. A scintillometer obtains a path averaged U⊥, which for some applications (e.g. at airports) is an advantage compared to other wind measurement devices. Applying Taylor's frozen turbulence assumption the signals of the two scintillometers should be the same except for a small time shift between the two signals, from which U⊥ can be determined. This time shift can be obtained from the time-lagged-correlation function of the two signals (r12 (τ)). Four methods were used to obtain U⊥; the peak method, the Briggs method, the zero-slope method, and the correlation method. The last one is a new method introduced in this study, which obtains U⊥ by comparing r12 (τ) of a measurement to r12 (τ) of Lawrence et al. (1972) theoretical model. U⊥ values obtained from the scintillometer were validated against sonic anemometer measurements. The best results were obtained by the zero-slope method and the correlation method. The zero-slope method gave the best results for low U⊥ values (< 2 m s-1), while the correlation method gave the best results for high U⊥ values (> 2 m s-1). The

  6. Measurements of underwater acoustic pressure fields using a scanning laser Doppler vibrometer

    NASA Astrophysics Data System (ADS)

    Carroll, Gerard P.

    2004-05-01

    Laser Doppler vibrometers (LDV) are designed to measure structural vibration velocity by sensing the phase shift in the laser signal reflected from a vibrating source. It is known that index of refraction modulations resulting from acoustic pressure distributions along a laser light path will also cause a phase shift. Simpson et al. [J. Acoust. Soc. Am. 99(4), 2521(A) (1996)] have investigated this acousto-optic phase modulation as a possible contaminating effect for underwater LDV vibration measurements. This paper will investigate acousto-optic phase modulations measured by a scanning LDV as a method for measuring pressure radiating from underwater vibrating surfaces. This is done by passing the laser beam through the radiating pressure field and measuring the backscattered laser signal which is reflected off a rigid and retroreflective surface (outside the pressure field). It is shown experimentally, using the average pressure measured with an LDV over a plane in the vicinity of a vibrating structure, that the pressure at a far-field location normal to the plane can be determined.

  7. Ultrasonic database development for the acoustic inspection device: the velocity-attenuation measurement system (VAMS)

    SciTech Connect

    Diaz, Aaron A.; Burghard, Brion J.; Valencia, Juan D.; Samuel, Todd J.; Doctor, S. R.

    2004-08-01

    The inspection of sealed containers is a critical task for personnel charged with enforcing government policies, maintaining public safety, and ensuring national security. The Pacific Northwest National Laboratory (PNNL) has developed a portable, handheld acoustic inspection device (AID) that provides non-invasive container interrogation and material identification capabilities. The AID technology has been deployed worldwide and user's are providing feedback and requesting additional capabilities and functionality. Recently, PNNL has developed a laboratory-based system for automated, ultrasonic characterization of fluids to support database development for the AID. Using pulse-echo ultrasound, ultrasonic pulses are launched into a container or bulk-solid commodity. The return echoes from these pulses are analyzed in terms of time-of-flight and frequency content (as a function of temperature) to extract physical property measurements (acoustic velocity and attenuation) of the material under test. These measured values are then compared to a tailored database of materials and fluids property data acquired using the Velocity-Attenuation Measurement System (VAMS). This bench-top platform acquires key ultrasonic property measurements as a function of temperature and frequency. This paper describes the technical basis for operation of the VAMS, recent enhancements to the measurement algorithms for both the VAMS and AID technologies, and new measurement data from laboratory testing and performance demonstration activities. Applications for homeland security and counter terrorism, law enforcement, drug-interdiction and fuel transportation compliance activities will be discussed.

  8. The influence of phonetic context and formant measurement location on acoustic vowel space

    NASA Astrophysics Data System (ADS)

    Turner, Greg S.; Hutchings, David T.; Sylvester, Betsy; Weismer, Gary

    2003-04-01

    One way of depicting vowel production is by describing vowels within an F1/F2 acoustic vowel space. This acoustic measure illustrates the dispersion of F1 and F2 values at a specific moment in time (e.g., the temporal midpoint of a vowel) for the vowels of a given language. This measure has recently been used to portray vowel production in individuals with communication disorders such as dysarthria and is moderately related to the severity of the speech disorder. Studies aimed at identifying influential factors effecting measurement stability of vowel space have yet to be completed. The focus of the present study is to evaluate the influence of phonetic context and spectral measurement location on vowel space in a group of neurologically normal American English speakers. For this study, vowel space was defined in terms of the dispersion of the four corner vowels produced within a CVC syllable frame, where C includes six stop consonants in all possible combinations with each vowel. Spectral measures were made at the midpoint and formant extremes of the vowels. A discussion will focus on individual and group variation in vowel space as a function of phonetic context and temporal measurement location.

  9. Exploratory study on a statistical method to analyse time resolved data obtained during nanomaterial exposure measurements

    NASA Astrophysics Data System (ADS)

    Clerc, F.; Njiki-Menga, G.-H.; Witschger, O.

    2013-04-01

    Most of the measurement strategies that are suggested at the international level to assess workplace exposure to nanomaterials rely on devices measuring, in real time, airborne particles concentrations (according different metrics). Since none of the instruments to measure aerosols can distinguish a particle of interest to the background aerosol, the statistical analysis of time resolved data requires special attention. So far, very few approaches have been used for statistical analysis in the literature. This ranges from simple qualitative analysis of graphs to the implementation of more complex statistical models. To date, there is still no consensus on a particular approach and the current period is always looking for an appropriate and robust method. In this context, this exploratory study investigates a statistical method to analyse time resolved data based on a Bayesian probabilistic approach. To investigate and illustrate the use of the this statistical method, particle number concentration data from a workplace study that investigated the potential for exposure via inhalation from cleanout operations by sandpapering of a reactor producing nanocomposite thin films have been used. In this workplace study, the background issue has been addressed through the near-field and far-field approaches and several size integrated and time resolved devices have been used. The analysis of the results presented here focuses only on data obtained with two handheld condensation particle counters. While one was measuring at the source of the released particles, the other one was measuring in parallel far-field. The Bayesian probabilistic approach allows a probabilistic modelling of data series, and the observed task is modelled in the form of probability distributions. The probability distributions issuing from time resolved data obtained at the source can be compared with the probability distributions issuing from the time resolved data obtained far-field, leading in a

  10. Remote vibration measurement: A wireless passive surface acoustic wave resonator fast probing strategy

    NASA Astrophysics Data System (ADS)

    Friedt, J.-M.; Droit, C.; Ballandras, S.; Alzuaga, S.; Martin, G.; Sandoz, P.

    2012-05-01

    Surface acoustic wave (SAW) resonators can advantageously operate as passive sensors which can be interrogated through a wireless link. Amongst the practical applications of such devices, structural health monitoring through stress measurement and more generally vibration characteristics of mechanical structures benefit from the ability to bury such sensors within the considered structure (wireless and battery-less). However, measurement bandwidth becomes a significant challenge when measuring wideband vibration characteristics of mechanical structures. A fast SAW resonator measurement scheme is demonstrated here. The measurement bandwidth is limited by the physical settling time of the resonator (Q/π periods), requiring only two probe pulses through a monostatic RADAR-like electronic setup to identify the sensor resonance frequency and hence stress on a resonator acting as a strain gauge. A measurement update rate of 4800 Hz using a high quality factor SAW resonator operating in the 434 MHz Industrial, Scientific and Medical band is experimentally demonstrated.

  11. Remote vibration measurement: a wireless passive surface acoustic wave resonator fast probing strategy.

    PubMed

    Friedt, J-M; Droit, C; Ballandras, S; Alzuaga, S; Martin, G; Sandoz, P

    2012-05-01

    Surface acoustic wave (SAW) resonators can advantageously operate as passive sensors which can be interrogated through a wireless link. Amongst the practical applications of such devices, structural health monitoring through stress measurement and more generally vibration characteristics of mechanical structures benefit from the ability to bury such sensors within the considered structure (wireless and battery-less). However, measurement bandwidth becomes a significant challenge when measuring wideband vibration characteristics of mechanical structures. A fast SAW resonator measurement scheme is demonstrated here. The measurement bandwidth is limited by the physical settling time of the resonator (Q/π periods), requiring only two probe pulses through a monostatic RADAR-like electronic setup to identify the sensor resonance frequency and hence stress on a resonator acting as a strain gauge. A measurement update rate of 4800 Hz using a high quality factor SAW resonator operating in the 434 MHz Industrial, Scientific and Medical band is experimentally demonstrated.

  12. System and method for sonic wave measurements using an acoustic beam source

    DOEpatents

    Vu, Cung Khac; Sinha, Dipen N.; Pantea, Cristian

    2015-08-11

    A method and system for investigating structure near a borehole are described herein. The method includes generating an acoustic beam by an acoustic source; directing at one or more azimuthal angles the acoustic beam towards a selected location in a vicinity of a borehole; receiving at one or more receivers an acoustic signal, the acoustic signal originating from a reflection or a refraction of the acoustic wave by a material at the selected location; and analyzing the received acoustic signal to characterize features of the material around the borehole.

  13. Assessment of Systematic Measurement Errors for Acoustic Travel-Time Tomography of the Atmosphere

    DTIC Science & Technology

    2013-01-01

    times obtained with Algorithm 3, the reconstructions become relatively accurate, see Figs. 6(g), 6( h ), and 6(i). The magnitudes of all fields are...Temperature. (e) u0 þ u. (f) v0 þ v. Reconstruction with the estimated systematic errors by Algorithm 3: (g) Temperature. ( h ) u0 þ u. (i) v0 þ v. TABLE V...tomographic monitoring of the atmospheric surface layer,” J. Atmos. Ocean. Technol. 11, 751–769 (1994). 2A. Ziemann, K. Arnold, and A. Raabe , “Acoustic

  14. Acoustic Monitor for Solid-Liquid Slurries Measurements at Low Weight Fractions

    SciTech Connect

    Tavlarides, Lawrence L.; Shcherbakov, Oleksandr; Dievendorf, Eric; Sangini, Ashok

    2003-09-10

    We have developed an acoustic monitor for accurate, real-time measurement of solids concentration in solid-liquid (S-L) and solid-gas-liquid (S-G-L) slurries at low solids weight percent (0.5 to 10 wt. %). The Syracuse Acoustic Monitor (SAM) has potential for slurry transport monitoring, processing stream monitoring, and process control capabilities for nuclear wastes treatment throughout the DOE complex. The SAM is based on theory that predicts attenuation of small-amplitude acoustic waves propagating through S-L and S-L-G suspensions. We developed a prototype in-line system with robust data acquisition capabilities to continually acquire attenuation data (response time of 0.5 sec) for a 0.6-12 MHz frequency range with an array of transducers. Test results on an integrated flow loop indicate high accuracy between 0.5 and 8.0 weight percent solids for ceramic microspheres (80 {micro}m average diameter) and kaolin-bentonite slurries. Results of removal of the interference caused by gas bubbles, thus providing the solids weight percent, will also be discussed.

  15. Subjective, laryngoscopic, and acoustic measurements of laryngeal reflux before and after treatment with omeprazole.

    PubMed

    Shaw, G Y; Searl, J P; Young, J L; Miner, P B

    1996-12-01

    Laryngeal manifestation of gastroesophageal reflux is felt to be prevalent in our society. In general, diagnosis has been based primarily on symptoms. Historically, additional testing included laryngoscopy, barium swallow, manometry, and more recently, single- and double-probe pH monitoring. We evaluated 68 patients who were symptomatically suggestive of having reflux laryngitis. We administered surveys grading their symptoms. All patients underwent standardized videolaryngostroboscopic evaluation and computerized acoustic analysis. Patients then underwent a uniform therapy of dietary restrictions and omeprazole, a hydrogen ion inhibitor, for 12 weeks. Patients were then retested. This regimen demonstrated an 85% success of relieving symptoms. Utilizing the new laryngoscopic grading system, improvement was found to be statistically significant in improvement of all findings except granulomas. In patients with the pretherapy complaint of hoarseness, acoustic measures of jitter, shimmer, habitual frequency, and frequency range all showed significant improvement. The authors conclude that in patients with symptomatic reflux laryngitis, standardized videolaryngoscopy and, if hoarse, acoustic analysis are useful exam techniques to aide diagnosis and monitor therapy. Anti-reflux therapy with omeprazole is effective and improvement can be objectively demonstrated with the techniques described.

  16. Measurement of acoustic dissipation in an experimental combustor under representative conditions

    NASA Astrophysics Data System (ADS)

    Webster, Samuel; Hardi, Justin; Oschwald, Michael

    2017-03-01

    The present paper is concerned with experimental estimation of acoustic dissipation under conditions representative of those in a rocket engine combustion chamber. Specifically, the influence of operating and injection conditions on acoustic dissipation is considered. Two experimental and analytical techniques are applied to measure and then compare dissipation rates of the first longitudinal and transverse acoustic modes in an experimental combustion chamber. Comparison between non-combustion and combustion tests showed that combustion chamber damping for the first transverse mode is far greater under combustion conditions. A lesser difference between non-combustion and combustion tests for the first longitudinal mode was found although the damping rates during combustion tests were still higher. A strong relationship between primary injection velocity and dissipation rate was observed, with lower injection velocities leading to decreased damping rates of the first transverse mode. Furthermore, increased film cooling injection rate decreased dissipation rate. The significant influence of representative conditions, specifically injection conditions, on dissipation rate has strong implications for both combustor design and experimental approaches aimed at quantifying dissipation in rocket combustion chambers.

  17. MEASUREMENTS OF ABSORPTION, EMISSIVITY REDUCTION, AND LOCAL SUPPRESSION OF SOLAR ACOUSTIC WAVES IN SUNSPOTS

    SciTech Connect

    Chou, D.-Y.; Liang, Z.-C.; Yang, M.-H.; Zhao Hui; Sun, M.-T.

    2009-05-01

    The power of solar acoustic waves in magnetic regions is lower relative to the quiet Sun. Absorption, emissivity reduction, and local suppression of acoustic waves contribute to the observed power reduction in magnetic regions. We propose a model for the energy budget of acoustic waves propagating through a sunspot in terms of the coefficients of absorption, emissivity reduction, and local suppression of the sunspot. Using the property that the waves emitted along the wave path between two points have no correlation with the signal at the starting point, we can separate the effects of these three mechanisms. Applying this method to helioseismic data filtered with direction and phase-velocity filters, we measure the fraction of the contribution of each mechanism to the power deficit in the umbra of the leading sunspot of NOAA 9057. The contribution from absorption is 23.3 {+-} 1.3%, emissivity reduction 8.2 {+-} 1.4%, and local suppression 68.5 {+-} 1.5%, for a wave packet corresponding to a phase velocity of 6.98 x 10{sup -5} rad s{sup -1}.

  18. Micro/meso scale fatigue damage accumulation monitoring using nonlinear acoustic vibro-modulation measurements

    NASA Astrophysics Data System (ADS)

    Zagrai, Andrei; Donskoy, Dimitri; Chudnovsky, Alexander; Golovin, Edward; Agarwala, Vinod S.

    2006-03-01

    Monitoring the incipient damage at the earliest possible stage is essential for predicting structural performance and remaining life of structural components. Existing prognostic methodologies incorporate conventional SHM and NDE techniques responsive to cracks and delaminations resulted from the irreversible material fracture and disintegration at the macro-scale. There is an increasing need for technologies that could allow for monitoring material degradation at the micro/meso scale before the onset of the macro-scale fracture. In this contribution, we report results of the real-time monitoring of the material micro/meso scale degradation using the nonlinear acoustic vibro-modulation technique. The technique explores nonlinear acoustic interaction of high frequency ultrasound and low frequency structural vibration at the site of the incipient damage. The indicator of the damage severity, nonlinear acoustic damage index (DI), was measured in real time during the strain-controlled three-point bending fatigue test of aluminum and steel specimens. Nondestructively, degradation of the specimen was revealed through the increase in the DI, which correlated well with the respective decrease in the specimen's stiffness. Destructive SEM examination confirmed sensitivity of the DI to the incipient micro/meso scale damage and advocated for utilizing the vibro-modulation approach for assessment of material degradation before fracture.

  19. Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography

    PubMed Central

    Polat, Onur; Baysal, Zeki; Özcan, Serkan; İnan, Sibel; İnan, Ümit Übeyt

    2016-01-01

    Objectives: To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. Materials and Methods: Data obtained using the Aladdin and Sirius systems from 110 eyes of 59 subjects who had no health problems other than refractive errors were retrospectively evaluated. Anterior chamber depth (ACD), flat (K1) and steep (K2) keratometry readings, and white-to-white distance (WTW) measurements taken with both devices were noted. Results: The mean age of the patients was 47.31±18.57 years (range, 25 to 79 years). Mean ACD was 3.35±0.4 mm using Aladdin and 3.42±0.44 mm using Sirius. Mean difference in ACD was 0.075 mm greater with Sirius than Aladdin (p<0.001). K1 measurement obtained by Aladdin was an average of 0.409 D higher (p<0.001). No statistically significant differences were detected between the two devices in respect to K2 and WTW measurements (p=0.18, p=0.85 respectively). Pearson correlation analysis showed high correlation between the two devices for all measurements (r=0.985, 0.895, 0.961 and 0.766 for ACD, K1, K2 and WTW respectively; p<0.001). Conclusion: Anterior segment parameters obtained by Aladdin optical biometer and Sirius anterior segment analysis system correlated well with each other and measurement differences between the devices were clinically negligible except for K1 values. PMID:28050321

  20. An Optimal Estimation Method to Obtain Surface Layer Turbulent Fluxes from Profile Measurements

    NASA Astrophysics Data System (ADS)

    Kang, D.

    2015-12-01

    In the absence of direct turbulence measurements, the turbulence characteristics of the atmospheric surface layer are often derived from measurements of the surface layer mean properties based on Monin-Obukhov Similarity Theory (MOST). This approach requires two levels of the ensemble mean wind, temperature, and water vapor, from which the fluxes of momentum, sensible heat, and water vapor can be obtained. When only one measurement level is available, the roughness heights and the assumed properties of the corresponding variables at the respective roughness heights are used. In practice, the temporal mean with large number of samples are used in place of the ensemble mean. However, in many situations the samples of data are taken from multiple levels. It is thus desirable to derive the boundary layer flux properties using all measurements. In this study, we used an optimal estimation approach to derive surface layer properties based on all available measurements. This approach assumes that the samples are taken from a population whose ensemble mean profile follows the MOST. An optimized estimate is obtained when the results yield a minimum cost function defined as a weighted summation of all error variance at each sample altitude. The weights are based one sample data variance and the altitude of the measurements. This method was applied to measurements in the marine atmospheric surface layer from a small boat using radiosonde on a tethered balloon where temperature and relative humidity profiles in the lowest 50 m were made repeatedly in about 30 minutes. We will present the resultant fluxes and the derived MOST mean profiles using different sets of measurements. The advantage of this method over the 'traditional' methods will be illustrated. Some limitations of this optimization method will also be discussed. Its application to quantify the effects of marine surface layer environment on radar and communication signal propagation will be shown as well.

  1. Comparison between body fat measurements obtained by portable ultrasound and caliper in young adults.

    PubMed

    Ulbricht, L; Neves, E B; Ripka, W L; Romaneli, E F R

    2012-01-01

    The objective of this study was to compare and correlate the Portable Ultra Sound (US) measuring technique to the skinfold measuring technique (SF) to estimate body fat percentage (%F) in young adults. Sixty military were evaluated, all males, divided in two groups: Group 1 (normal) composed by 30 military with Body Mass Index (BMI) until 24.99 kg/m(2) and Group 2 (overweight) composed by 30 military with BMI > 25 kg/m(2). Weight, height, skinfolds and ultrasound were measured in 9 points (triceps, subscapular, biceps, chest, medium axillary, abdominal, suprailiac, thigh and calf). Body fat average values obtained by skinfold thickness and ultrasound measurements were 13.25 ± 6.32 % and 12.73 ± 5.95 % respectively. Despite significant differences in measurements of each anatomical site, it was possible to verify that the total final body fat percentage calculated by both techniques did not present significant differences and that overweight group presented greater similarity between the values obtained using caliper and ultrasound equipment.

  2. Ram-wake measurements obtained from the ionospheric sounding rocket MAIMIK

    SciTech Connect

    Svenes, K.R.; Troim, J.; Maehlum, B.N.; Friedrich, M.; Torkar, K.M.

    1990-01-01

    Results of plasma measurements from the ionospheric sounding rocket MAIMIK are reported. Data obtained by high-resolution plasma probes show distinct classical wake signatures during the entire flight. That is, the electron temperature was enhanced behind the rocket in a region where both the electron and ion density were well below the ambient values. In addition, electron temperature enhancements were also detected in the ram (forward) direction on the downleg. The measurements are presented and discussed in relation to the prevailing ionospheric conditions.

  3. Monitoring glucose in vivo by measuring laser-induced acoustic profiles

    NASA Astrophysics Data System (ADS)

    Bednov, Andrey A.; Karabutov, Alexander A.; Savateeva, Elena V.; March, Wayne F.; Oraevsky, Alexander A.

    2000-05-01

    The optoacoustic method of monitoring absorbed optical energy distribution in tissues was employed to measure changes in glucose concentration in vivo. Glucose osmotic and hydrophilic properties cause reduction of tissue scattering as a result of glucose concentration increase around scattering particles and fibers. The opto-acoustic (OA) method utilizes time-resolved measurements of laser- induced ultrasonic profile in tissue resembling the distribution of absorbed optical energy. This opto-acoustic profile yields effective optical attenuation coefficient, which decreases with decrease of scattering. Glucose effect has been investigated initially in phantoms resembling optical properties of sclera and polystyrene microspheres water solution colored with potassium chromate and then in sclera in vitro and in sclera of live rabbits. The forward mode of opto-acoustic detection was used in the experiments in vitro. Experiments were performed in UV spectral range at the wavelength of (lambda) equals 355-nm. Experimental results demonstrated that an increase in glucose concentration from 5 mM to 60 mM was expressed in the 3 percent reduction of (mu) eff in aqueous solution of polystyrene microspheres. The effect of glucose on sclera in vitro was more prominent and measured as 10 percent reduction of (mu) eff with increase of glucose concentration from 1 mM to 50 mM. It was found that both the amplitude and the profile of OA signal were influenced by mechanical pressure applied to sclera specimen toward the surface of OA transducer. In experiments in live tissue, the backward detection mode was employed, as the only one side access to the tissue surface was available. In experiments in vivo the opto-acoustic profiles were measured in rabbit's sclera before and after intravenous glucose administering. The glucose concentration in rabbit blood was simultaneously measured using commercial device employing chemical analysis of blood. Experimental results demonstrated that a 1

  4. Measurements of speech intelligibility in common rooms for older adults as a first step towards acoustical guidelines.

    PubMed

    Reinten, Jikke; van Hout, Nicole; Hak, Constant; Kort, Helianthe

    2015-01-01

    Adapting the built environment to the needs of nursing- or care-home residents has become common practice. Even though hearing loss due to ageing is a normal occurring biological process, little research has been performed on the effects of room acoustic parameters on the speech intelligibility for older adults. This article presents the results of room acoustic measurements in common rooms for older adults and the effect on speech intelligibility. Perceived speech intelligibility amongst the users of the rooms was also investigated. The results have led to ongoing research at Utrecht University of Applied Sciences and Eindhoven University of Technology, aimed at the development of acoustical guidelines for elderly care facilities.

  5. Reliability of Phase Velocity Measurements of Flexural Acoustic Waves in the Human Tibia In-Vivo

    PubMed Central

    2016-01-01

    Purpose Axial-transmission acoustics have shown to be a promising technique to measure individual bone properties and detect bone pathologies. With the ultimate goal being the in-vivo application of such systems, quantification of the key aspects governing the reliability is crucial to bring this method towards clinical use. Materials and Methods This work presents a systematic reliability study quantifying the sources of variability and their magnitudes of in-vivo measurements using axial-transmission acoustics. 42 healthy subjects were measured by an experienced operator twice per week, over a four-month period, resulting in over 150000 wave measurements. In a complementary study to assess the influence of different operators performing the measurements, 10 novice operators were trained, and each measured 5 subjects on a single occasion, using the same measurement protocol as in the first part of the study. Results The estimated standard error for the measurement protocol used to collect the study data was ∼ 17 m/s (∼ 4% of the grand mean) and the index of dependability, as a measure of reliability, was Φ = 0.81. It was shown that the method is suitable for multi-operator use and that the reliability can be improved efficiently by additional measurements with device repositioning, while additional measurements without repositioning cannot improve the reliability substantially. Phase velocity values were found to be significantly higher in males than in females (p < 10−5) and an intra-class correlation coefficient of r = 0.70 was found between the legs of each subject. Conclusions The high reliability of this non-invasive approach and its intrinsic sensitivity to mechanical properties opens perspectives for the rapid and inexpensive clinical assessment of bone pathologies, as well as for monitoring programmes without any radiation exposure for the patient. PMID:27015093

  6. Thermal Boundary Resistance between GaN and Cubic Ice and THz Acoustic Attenuation Spectrum of Cubic Ice from Complex Acoustic Impedance Measurements.

    PubMed

    Mante, Pierre-Adrien; Chen, Chien-Cheng; Wen, Yu-Chieh; Sheu, Jinn-Kong; Sun, Chi-Kuang

    2013-11-27

    A phonon nanoscopy method, based on the picosecond ultrasonics technique, capable of studying the complex acoustic reflection coefficient at frequency up to 1 THz is proposed and demonstrated. By measuring the reflection coefficient at the same surface location at the interface between GaN and air, and between GaN and the material to characterize, we get access to the THz amplitude and phase spectra of the acoustic phonon reflection. The retrieval of both these pieces of information then allows the calculation of the attenuation in a wide range of frequency and gives new insight into the Kapitza anomaly. This method is then applied to cubic ice, and the measurements of the elastic properties, the phonon anharmonic decay spectrum up to 1 THz, as well as the measurements of the thermal phonon lifetime at 150 K are all achieved.

  7. Validation of exposure time for discharge measurements made with two bottom-tracking acoustic doppler current profilers

    USGS Publications Warehouse

    Czuba, J.A.; Oberg, K.

    2008-01-01

    Previous work by Oberg and Mueller of the U.S. Geological Survey in 2007 concluded that exposure time (total time spent sampling the flow) is a critical factor in reducing measurement uncertainty. In a subsequent paper, Oberg and Mueller validated these conclusions using one set of data to show that the effect of exposure time on the uncertainty of the measured discharge is independent of stream width, depth, and range of boat speeds. Analysis of eight StreamPro acoustic Doppler current profiler (ADCP) measurements indicate that they fall within and show a similar trend to the Rio Grande ADCP data previously reported. Four special validation measurements were made for the purpose of verifying the conclusions of Oberg and Mueller regarding exposure time for Rio Grande and StreamPro ADCPs. Analysis of these measurements confirms that exposure time is a critical factor in reducing measurement uncertainty and is independent of stream width, depth, and range of boat speeds. Furthermore, it appears that the relation between measured discharge uncertainty and exposure time is similar for both Rio Grande and StreamPro ADCPs. These results are applicable to ADCPs that make use of broadband technology using bottom-tracking to obtain the boat velocity. Based on this work, a minimum of two transects should be collected with an exposure time for all transects greater than or equal to 720 seconds in order to achieve an uncertainty of ??5 percent when using bottom-tracking ADCPs. ?? 2008 IEEE.

  8. Visualization of through-plane blood flow measurements obtained from phase-contrast MRI.

    PubMed

    Thunberg, Per; Kähäri, Anders

    2011-06-01

    The purpose of this work was to develop a visualization method for concurrent observation of both velocity and magnitude data obtained from through-plane velocity measurements using phase-contrast magnetic resonance imaging. Magnitude and velocity images were combined using an opacity transfer function (OTF) where the opacity was a function of a velocity range defined by the velocity encoding (v (enc)) parameter. Measured velocities were color-coded according to a predefined color scale and then combined into one image with the gray-scale magnitude image according to the OTF. In the combined images, simultaneous information of velocity and anatomy was presented. The proposed visualization method facilitated the understanding of how the measured blood flow was related to the underlying anatomy. Results are shown where the method is used to visualize blood flow measurements in the ascending aorta and the aortic valve. Adjustments of the OTF render possible identification of the peak velocities and their localization. Forward and backward blood flow is easily shown when applying appropriate OTF and color-coding. An advantage when using the proposed method is the ability of developing standardized protocol settings since the velocity information is quantitative and not relative as is the case for data obtained from the magnitude images. The intended application of the visualization method is the analysis of common flow studies used in the diagnosis of different cardiovascular diseases.

  9. Quantitative measurements of acoustic emissions from cavitation at the surface of a stone in response to a lithotripter shock wave.

    PubMed

    Chitnis, Parag V; Cleveland, Robin O

    2006-04-01

    Measurements are presented of acoustic emissions from cavitation collapses on the surface of a synthetic kidney stone in response to shock waves (SWs) from an electrohydraulic lithotripter. A fiber optic probe hydrophone was used for pressure measurements, and passive cavitation detection was used to identify acoustic emissions from bubble collapse. At a lithotripter charging voltage of 20 kV, the focused SW incident on the stone surface resulted in a peak pressure of 43 +/- 6 MPa compared to 23 +/- 4 MPa in the free field. The focused SW incident upon the stone appeared to be enhanced due to the acoustic emissions from the forced cavitation collapse of the preexisting bubbles. The peak pressure of the acoustic emission from a bubble collapse was 34 +/- 15 MPa, that is, the same magnitude as the SWs incident on the stone. These data indicate that stresses induced by focused SWs and cavitation collapses are similar in magnitude thus likely play a similar role in stone fragmentation.

  10. Picosecond acoustics method for measuring the thermodynamical properties of solids and liquids at high pressure and high temperature.

    PubMed

    Decremps, F; Gauthier, M; Ayrinhac, S; Bove, L; Belliard, L; Perrin, B; Morand, M; Le Marchand, G; Bergame, F; Philippe, J

    2015-02-01

    Based on the original combination of picosecond acoustics and diamond anvils cell, recent improvements to accurately measure hypersonic sound velocities of liquids and solids under extreme conditions are described. To illustrate the capability of this technique, results are given on the pressure and temperature dependence of acoustic properties for three prototypical cases: polycrystal (iron), single-crystal (silicon) and liquid (mercury) samples. It is shown that such technique also enables the determination of the density as a function of pressure for liquids, of the complete set of elastic constants for single crystals, and of the melting curve for any kind of material. High pressure ultrafast acoustic spectroscopy technique clearly opens opportunities to measure thermodynamical properties under previously unattainable extreme conditions. Beyond physics, this state-of-the-art experiment would thus be useful in many other fields such as nonlinear acoustics, oceanography, petrology, in of view. A brief description of new developments and future directions of works conclude the article.

  11. Experimental determination of the viscous flow permeability of porous materials by measuring reflected low frequency acoustic waves

    NASA Astrophysics Data System (ADS)

    Berbiche, A.; Sadouki, M.; Fellah, Z. E. A.; Ogam, E.; Fellah, M.; Mitri, F. G.; Depollier, C.

    2016-01-01

    An acoustic reflectivity method is proposed for measuring the permeability or flow resistivity of air-saturated porous materials. In this method, a simplified expression of the reflection coefficient is derived in the Darcy's regime (low frequency range), which does not depend on frequency and porosity. Numerical simulations show that the reflection coefficient of a porous material can be approximated by its simplified expression obtained from its Taylor development to the first order. This approximation is good especially for resistive materials (of low permeability) and for the lower frequencies. The permeability is reconstructed by solving the inverse problem using waves reflected by plastic foam samples, at different frequency bandwidths in the Darcy regime. The proposed method has the advantage of being simple compared to the conventional methods that use experimental reflected data, and is complementary to the transmissivity method, which is more adapted to low resistive materials (high permeability).

  12. A comparison of systolic blood pressure measurement obtained using a pulse oximeter, and direct systolic pressure measurement in anesthetized sows.

    PubMed Central

    Caulkett, N A; Duke, T; Bailey, J V

    1994-01-01

    Systolic blood pressure measurement obtained with a pulse oximeter has been compared to values obtained by other indirect methods in man. Direct pressure measurement is subject to less error than indirect techniques. This study was designed to compare systolic pressure values obtained using a pulse oximeter, with values obtained by direct arterial pressure measurement. The pulse oximeter waveform was used as an indication of perfusion. A blood pressure cuff was applied proximal to the pulse oximeter probe. The cuff was inflated until the oximeter waveform disappeared, this value was recorded as the systolic pressure at the disappearance of the waveform (SPD). The cuff was inflated to a pressure > 200 mmHg, then gradually deflated until the waveform reappeared, this value was recorded as the systolic pressure at reappearance of the waveform (SPR). The average of the two values, SPD and SPR, was calculated and recorded as SPA. The study was performed in sows (n = 21) undergoing cesarean section under epidural anesthesia and IV sedation. A total of 280 measurements were made of SPD, SPR and SPA. Regression analysis of SPA and direct measurement revealed a correlation coefficient (r) of 0.81. Calculation of mean difference (bias) and standard deviation of the bias (precision) for direct pressure--SPA revealed a value of 1.3 +/- 12.1. When compared with direct measurement, the correlation of this technique was similar to that recorded for other indirect techniques used in small animals. This indicates that this technique would be useful for following systolic pressure trends.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8004540

  13. Examination of the Measurement of Absorption Using the Reverberant Room Method for Highly Absorptive Acoustic Foam

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; McNelis, Anne M.; Chris Nottoli; Eric Wolfram

    2015-01-01

    The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.

  14. A Comparison Study of Normal-Incidence Acoustic Impedance Measurements of a Perforate Liner

    NASA Technical Reports Server (NTRS)

    Schultz, Todd; Liu, Fei; Cattafesta, Louis; Sheplak, Mark; Jones, Michael

    2009-01-01

    The eduction of the acoustic impedance for liner configurations is fundamental to the reduction of noise from modern jet engines. Ultimately, this property must be measured accurately for use in analytical and numerical propagation models of aircraft engine noise. Thus any standardized measurement techniques must be validated by providing reliable and consistent results for different facilities and sample sizes. This paper compares normal-incidence acoustic impedance measurements using the two-microphone method of ten nominally identical individual liner samples from two facilities, namely 50.8 mm and 25.4 mm square waveguides at NASA Langley Research Center and the University of Florida, respectively. The liner chosen for this investigation is a simple single-degree-of-freedom perforate liner with resonance and anti-resonance frequencies near 1.1 kHz and 2.2 kHz, respectively. The results show that the ten measurements have the most variation around the anti-resonance frequency, where statistically significant differences exist between the averaged results from the two facilities. However, the sample-to-sample variation is comparable in magnitude to the predicted cross-sectional area-dependent cavity dissipation differences between facilities, providing evidence that the size of the present samples does not significantly influence the results away from anti-resonance.

  15. Measurement of Insertion Loss of an Acoustic Treatment in the Presence of Additional Uncorrelated Sound Sources

    NASA Technical Reports Server (NTRS)

    Klos, Jacob; Palumbo, Daniel L.

    2003-01-01

    A method to intended for measurement of the insertion loss of an acoustic treatment applied to an aircraft fuselage in-situ is documented in this paper. Using this method, the performance of a treatment applied to a limited portion of an aircraft fuselage can be assessed even though the untreated fuselage also radiates into the cabin, corrupting the intensity measurement. This corrupting noise in the intensity measurement incoherent with the panel vibration of interest is removed by correlating the intensity to reference transducers such as accelerometers. Insertion loss of the acoustic treatments is estimated from the ratio of correlated intensity measurements with and without a treatment applied. In the case of turbulent boundary layer excitation of the fuselage, this technique can be used to assess the performance of noise control methods without requiring treatment of the entire fuselage. Several experimental studies and numerical simulations have been conducted, and results from three case studies are documented in this paper. Conclusions are drawn about the use of this method to study aircraft sidewall treatments.

  16. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    NASA Technical Reports Server (NTRS)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  17. Ultrasonic Measurement of Strain Distribution Inside Object Cyclically Compressed by Dual Acoustic Radiation Force

    NASA Astrophysics Data System (ADS)

    Odagiri, Yoshitaka; Hasegawa, Hideyuki; Kanai, Hiroshi

    2008-05-01

    One possible way to evaluate acupuncture therapy quantitatively is to measure the change in the elastic property of muscle after application of the therapy. Many studies have been conducted to measure mechanical properties of tissues using ultrasound-induced acoustic radiation force. To assess mechanical properties, strain must be generated in an object. However, a single radiation force is not effective because it mainly generates translational motion when the object is much harder than the surrounding medium. In this study, two cyclic radiation forces are simultaneously applied to a muscle phantom from two opposite horizontal directions so that the object is cyclically compressed in the horizontal direction. By the horizontal compression, the object is expanded vertically based on its incompressibility. The resultant vertical displacement is measured using another ultrasound pulse. Two ultrasonic transducers for actuation were both driven by the sum of two continuous sinusoidal signals at two slightly different frequencies [1 MHz and (1 M + 5) Hz]. The displacement of several micrometers in amplitude, which fluctuated at 5 Hz, was measured by the ultrasonic phased tracking method. Increase in thickness inside the object was observed just when acoustic radiation forces increased. Such changes in thickness correspond to vertical expansion due to horizontal compression.

  18. Indirect calibration of a large microphone array for in-duct acoustic measurements

    NASA Astrophysics Data System (ADS)

    Leclère, Q.; Pereira, A.; Finez, A.; Souchotte, P.

    2016-08-01

    This paper addresses the problem of in situ calibration of a pin hole-mounted microphone array for in-duct acoustic measurements. One approach is to individually measure the frequency response of each microphone, by submitting the probe to be calibrated and a reference microphone to the same pressure field. Although simple, this task may be very time consuming for large microphone arrays and eventually suffer from lack of access to microphones once they are installed on the test bench. An alternative global calibration procedure is thus proposed in this paper. The approach is based on the fact that the acoustic pressure can be expanded onto an analytically known spatial basis. A projection operator is defined allowing the projection of measurements onto the duct modal basis. The main assumption of the method is that the residual resulting from the difference between actual and projected measurements is mainly dominated by calibration errors. An iterative procedure to estimate the calibration factors of each microphone is proposed and validated through an experimental set-up. In addition, it is shown that the proposed scheme allows an optimization of physical parameters such as the sound speed and parameters associated to the test bench itself, such as the duct radius or the termination reflection coefficient.

  19. Comparison of ozone profiles obtained with NIES DIAL and SAGE II measurements

    NASA Technical Reports Server (NTRS)

    Nakane, Hideaki; Sasano, Yasuhiro; Hayashida-Amano, Sachiko; Sugimoto, Nobuo; Matsui, Ichiro; Minato, Atsushi; Mccormick, M. P.

    1993-01-01

    Ozone profiles obtained with the Differential Absorption Lidar (DIAL) system at the National Institute for Environmental Studies (NIES) (Tsukuba, Japan) were compared with data provided by the satellite sensor SAGE II. The SAGE II data were selected based on criteria of spatial and temporal differences between the DIAL and the SAGE II measurements: five degrees in latitude and 15 degrees in longitude, within a latitudinal band from 31 deg to 41 deg N, and within one, three and five days after or before the DIAL measurements. Results show very good agreement for the individual and the zonal-mean profiles. The average mean difference between the DIAL and the SAGE II measurements over the altitudes 15-50 km was about 10 percent.

  20. Galaxy bias and its effects on the Baryon acoustic oscillations measurements

    SciTech Connect

    Mehta, Kushal T.; Seo, Hee -Jong; Eckel, Jonathan; Eisenstein, Daniel J.; Metchnik, Marc; Pinto, Philip; Xu, Xiaoying

    2011-05-31

    The baryon acoustic oscillation (BAO) feature in the clustering of matter in the universe serves as a robust standard ruler and hence can be used to map the expansion history of the universe. We use high force resolution simulations to analyze the effects of galaxy bias on the measurements of the BAO signal. We apply a variety of Halo Occupation Distributions (HODs) and produce biased mass tracers to mimic different galaxy populations. We investigate whether galaxy bias changes the non-linear shifts on the acoustic scale relative to the underlying dark matter distribution presented by Seo et al. (2009). For the less biased HOD models (b < 3), we do not detect any shift in the acoustic scale relative to the no-bias case, typically 0.10% ± 0.10%. However, the most biased HOD models (b > 3) show a shift at moderate significance (0.79% ± 0.31% for the most extreme case). We test the one-step reconstruction technique introduced by Eisenstein et al. (2007) in the case of realistic galaxy bias and shot noise. The reconstruction scheme increases the correlation between the initial and final (z = 1) density fields achieving an equivalent level of correlation at nearly twice the wavenumber after reconstruction. Reconstruction reduces the shifts and errors on the shifts. We find that after reconstruction the shifts from the galaxy cases and the dark matter case are consistent with each other and with no shift. The 1σ systematic errors on the distance measurements inferred from our BAO measurements with various HODs after reconstruction are about 0.07%-0.15%.

  1. Passive broadband acoustic thermometry

    NASA Astrophysics Data System (ADS)

    Anosov, A. A.; Belyaev, R. V.; Klin'shov, V. V.; Mansfel'd, A. D.; Subochev, P. V.

    2016-04-01

    The 1D internal (core) temperature profiles for the model object (plasticine) and the human hand are reconstructed using the passive acoustothermometric broadband probing data. Thermal acoustic radiation is detected by a broadband (0.8-3.5 MHz) acoustic radiometer. The temperature distribution is reconstructed using a priori information corresponding to the experimental conditions. The temperature distribution for the heated model object is assumed to be monotonic. For the hand, we assume that the temperature distribution satisfies the heat-conduction equation taking into account the blood flow. The average error of reconstruction determined for plasticine from the results of independent temperature measurements is 0.6 K for a measuring time of 25 s. The reconstructed value of the core temperature of the hand (36°C) generally corresponds to physiological data. The obtained results make it possible to use passive broadband acoustic probing for measuring the core temperatures in medical procedures associated with heating of human organism tissues.

  2. Acoustic measurements from a rotor blade-vortex interaction noise experiment in the German-Dutch Wind Tunnel (DNW)

    NASA Technical Reports Server (NTRS)

    Martin, Ruth M.; Splettstoesser, W. R.; Elliott, J. W.; Schultz, K.-J.

    1988-01-01

    Acoustic data are presented from a 40 percent scale model of the 4-bladed BO-105 helicopter main rotor, measured in the large European aeroacoustic wind tunnel, the DNW. Rotor blade-vortex interaction (BVI) noise data in the low speed flight range were acquired using a traversing in-flow microphone array. The experimental apparatus, testing procedures, calibration results, and experimental objectives are fully described. A large representative set of averaged acoustic signals is presented.

  3. Field evaluation of shallow-water acoustic doppler current profiler discharge measurements

    USGS Publications Warehouse

    Rehmel, M.S.

    2007-01-01

    In 2004, the U.S. Geological Survey (USGS) Office of Surface Water staff and USGS Water Science employees began testing the StreamPro, an acoustic Doppler current profiler (ADCP) for shallow-water discharge measurements. Teledyne RD Instruments introduced the StreamPro in December of 2003. The StreamPro is designed to make a "moving boat" discharge measurement in streams with depths between 0.15 and 2 m. If the StreamPro works reliably in these conditions, it will allow for use of ADCPs in a greater number of streams than previously possible. Evaluation sites were chosen to test the StreamPro over a range of conditions. Simultaneous discharge measurements with mechanical and other acoustic meters, along with stable rating curves at established USGS streamflow-gaging stations, were used for comparisons. The StreamPro measurements ranged in mean velocity from 0.076 to 1.04 m/s and in discharge from 0.083 m 3/s to 43.4 m 3/s. Tests indicate that discharges measured with the StreamPro compare favorably to the discharges measured with the other meters when the mean channel velocity is greater than 0.25 m/s. When the mean channel velocity is less than 0.25 m/s, the StreamPro discharge measurements for individual transects have greater variability than those StreamPro measurements where the mean channel velocity is greater than 0.25 m/s. Despite this greater variation in individual transects, there is no indication that the StreamPro measured discharges (the mean discharge for all transects) are biased, provided that enough transects are used to determine the mean discharge. ?? 2007 ASCE.

  4. Implementation of distributed feedback fiber laser sensor for acoustic measurements in hydraulic fracturing

    NASA Astrophysics Data System (ADS)

    Chen, Rongzhang; Yan, Aidong; Zaghloul, Mohamed A. S.; Lu, Guanyi; Bunger, Andrew P.; Miller, Gary A.; Cranch, Geoffrey A.; Chen, Kevin P.

    2016-09-01

    A distributed feedback (DFB) fiber laser strain sensor was implemented to measure acoustic emission induced by the hydraulic fracturing process. A study of practical sensor mounting configurations and their characteristics was carried out to find a practical solution. Combining the suitable mounting configuration and ultrahigh strain sensitivity of the DFB fiber laser, the evolution of the hydraulic fracturing process was well monitored. This study shows that fiber lasers can be useful alternatives to piezoelectric sensors in the field of hydraulic fracturing for gas and oil extraction.

  5. Southeast Alaska Acoustic Measurement Facility (SEAFAC) environmental data base review, evaluation, and upgrade

    SciTech Connect

    Strand, J.A.; Skalski, J.R.; Faulkner, L.L.; Rodman, C.W.; Carlile, D.W.; Ecker, R.M.; Nicholls, A.K.; Ramsdell, J.V.; Scott, M.J.

    1986-04-01

    This report summarizes the principal issues of public concern, the adequacy of the environmental data base to answer the issues of concern, and the additional data collection required to support a National Environmental Policy Act (NEPA) review of the proposed Southeast Alaska Acoustic Measurement Facility (SEAFAC). The report is based on a review of the readily available environmental literature and a site visit. Representatives of local, state, and federal agencies were also interviewed for their personal insights and concerns not discovered during the literature review.

  6. Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

    NASA Technical Reports Server (NTRS)

    Dippold, Vance F., III

    2016-01-01

    A series of three convergent round-to-rectangular high-aspect ratio nozzles were designed for acoustics measurements. The nozzles have exit area aspect ratios of 8:1, 12:1, and 16:1. With septa inserts, these nozzles will mimic an array of distributed propulsion system nozzles, as found on hybrid wing-body aircraft concepts. Analyses were performed for the three nozzle designs and showed that the flow through the nozzles was free of separated flow and shocks. The exit flow was mostly uniform with the exception of a pair of vortices at each span-wise end of the nozzle.

  7. Compressive sensing beamforming based on covariance for acoustic imaging with noisy measurements.

    PubMed

    Zhong, Siyang; Wei, Qingkai; Huang, Xun

    2013-11-01

    Compressive sensing, a newly emerging method from information technology, is applied to array beamforming and associated acoustic applications. A compressive sensing beamforming method (CSB-II) is developed based on sampling covariance matrix, assuming spatially sparse and incoherent signals, and then examined using both simulations and aeroacoustic measurements. The simulation results clearly show that the proposed CSB-II method is robust to sensing noise. In addition, aeroacoustic tests of a landing gear model demonstrate the good performance in terms of resolution and sidelobe rejection.

  8. A modified beam-to-earth transformation to measure short-wavelength internal waves with an acoustic Doppler current profiler

    USGS Publications Warehouse

    Scotti, A.; Butman, B.; Beardsley, R.C.; Alexander, P.S.; Anderson, S.

    2005-01-01

    The algorithm used to transform velocity signals from beam coordinates to earth coordinates in an acoustic Doppler current profiler (ADCP) relies on the assumption that the currents are uniform over the horizontal distance separating the beams. This condition may be violated by (nonlinear) internal waves, which can have wavelengths as small as 100-200 m. In this case, the standard algorithm combines velocities measured at different phases of a wave and produces horizontal velocities that increasingly differ from true velocities with distance from the ADCP. Observations made in Massachusetts Bay show that currents measured with a bottom-mounted upward-looking ADCP during periods when short-wavelength internal waves are present differ significantly from currents measured by point current meters, except very close to the instrument. These periods are flagged with high error velocities by the standard ADCP algorithm. In this paper measurements from the four spatially diverging beams and the backscatter intensity signal are used to calculate the propagation direction and celerity of the internal waves. Once this information is known, a modified beam-to-earth transformation that combines appropriately lagged beam measurements can be used to obtain current estimates in earth coordinates that compare well with pointwise measurements. ?? 2005 American Meteorological Society.

  9. Bolt axial stress measurement based on a mode-converted ultrasound method using an electromagnetic acoustic transducer.

    PubMed

    Ding, Xu; Wu, Xinjun; Wang, Yugang

    2014-03-01

    A method is proposed to measure the stress on a tightened bolt using an electromagnetic acoustic transducer (EMAT). A shear wave is generated by the EMAT, and a longitudinal wave is obtained from the reflection of the shear wave due to the mode conversion. The ray paths of the longitudinal and the shear wave are analyzed, and the relationship between the bolt axial stress and the ratio of time of flight between two mode waves is then formulated. Based on the above outcomes, an EMAT is developed to measure the bolt axial stress without loosening the bolt, which is required in the conventional EMAT test method. The experimental results from the measurement of the bolt tension show that the shear and the mode-converted longitudinal waves can be received successfully, and the ratio of the times of flight of the shear and the mode-converted longitudinal waves is linearly proportional to the bolt axial tension. The non-contact characteristic of EMAT eliminates the effect of the couplant and also makes the measurement more convenient than the measurement performed using the piezoelectric transducer. This method provides a promising way to measure the stress on tightened bolts.

  10. Tropospheric Wind Measurements Obtained with the Goddard Lidar Observatory for Winds (GLOW): Validation and Performance

    NASA Technical Reports Server (NTRS)

    Gentry, Bruce M.; Einaudi, Franco (Technical Monitor)

    2001-01-01

    The Goddard Lidar Observatory for Winds (GLOW) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. GLOW is intended to be used as a field deployable system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In September of 2000 GLOW participated in a three week intercomparison experiment at the GroundWinds facility in North Glen, NE. More than 50 hours of line-of-sight wind profile data was obtained in a wide variety of conditions including both day and night operation. Typical clear air lidar wind profiles extended to altitudes of 20 km with a 1 Ian vertical resolution and I minute averaging. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the Goddard system during the New Hampshire experiment.

  11. Tropospheric Wind Measurements Obtained with the Goddard Lidar Observatory for Winds (GLOW): Validation and Performance

    NASA Technical Reports Server (NTRS)

    Gentry, Bruce M.; Chen, Huai-Lin; Einaudi, Franco (Technical Monitor)

    2001-01-01

    The Goddard Lidar Observatory for Winds (GLOW) is a mobile Doppler lidar system which uses direct detection Doppler lidar techniques to measure wind profiles from the surface into the lower stratosphere. GLOW is intended to be used as a field deployable system for studying atmospheric dynamics and transport and can also serve as a testbed to evaluate candidate technologies developed for use in future spaceborne systems. In September of 2000 GLOW participated in a three week intercomparison experiment at the GroundWinds facility in North Glen, NH. More than 50 hours of line-of-sight wind profile data were obtained in a wide variety of conditions including both day and night operation. Typical clear air lidar wind profiles extended to altitudes of 20 kin with a 1 km vertical resolution and 1 minute averaging. A description of the mobile system is presented along with the examples of lidar wind profiles obtained with the Goddard system during the New Hampshire experiment.

  12. Entanglement in bipartite pure states of an interacting boson gas obtained by local projective measurements

    SciTech Connect

    Paraan, Francis N. C.; Korepin, Vladimir E.; Molina-Vilaplana, Javier; Bose, Sougato

    2011-09-15

    We quantify the extractable entanglement of excited states of a Lieb-Liniger gas that are obtained from coarse-grained measurements on the ground state in which the boson number in one of two complementary contiguous partitions of the gas is determined. Numerically exact results obtained from the coordinate Bethe ansatz show that the von Neumann entropy of the resulting bipartite pure state increases monotonically with the strength of repulsive interactions and saturates to the impenetrable-boson limiting value. We also present evidence indicating that the largest amount of entanglement can be extracted from the most probable projected state having half the number of bosons in a given partition. Our study points to a fundamental difference between the nature of the entanglement in free-bosonic and free-fermionic systems, with the entanglement in the former being zero after projection, while that in the latter (corresponding to the impenetrable-boson limit) being nonzero.

  13. Direct Detection Doppler Lidar Wind Measurements Obtained During the 2002 International H2O Project (IHOP)

    NASA Technical Reports Server (NTRS)

    Gentry, Bruce; Li, Steven; Chen, Huai-Lin; Comer, Joseph; Mathur, Savyasachee; Bobler, Jeremy

    2005-01-01

    The Goddard Lidar Observatory for Winds (GLOW) is a mobile Doppler lidar system that uses direct detection techniques for profiling winds in the troposphere and lower stratosphere. In May and June of 2002 GLOW was deployed to the Southern Great Plains of the US to participate in the International H2O Project (IHOP). GLOW was located at the Homestead profiling site in the Oklahoma panhandle about 15 km east of the SPOL radar. Several other Goddard lidars, the Scanning Raman Lidar (SRL) and HARLIE, as well as radars and passive instruments were permanently operated from the Homestead site during the IHOP campaign providing a unique cluster of observations. During the IHOP observation period (May 14, 2002 to June 25, 2002) over 240 hours of wind profile measurements were obtained with GLOW. In this paper we will describe the GLOW instrument as it was configured for the IHOP campaign and we will present examples of wind profiles obtained.

  14. Range difference multilateration for obtaining precision geodetic and trajectory measurements. [by radio interferometry

    NASA Technical Reports Server (NTRS)

    Escobal, P. R.; Ong, K. M.; Von Roos, O. H.

    1975-01-01

    The theoretical aspects of a new multilateration technique suitable for precision geodesy and orbit determination applications are examined. The multilateration technique considered herein makes use of the differential time of arrival of signals at an ensemble of ground stations from a spacecraft or aircraft as the fundamental data type. It is demonstrated that simultaneous measurements give rise to a system of equations which upon solution permits the determination of the three-dimensional vehicle coordinates plus the three-dimensional coordinates of the station net relative to an arbitrarily adopted origin (which may be taken to be one of the stations). A solution to these equations can be obtained without any a priori knowledge of the locations of the stations and vehicle. The necessary conditions for obtaining all of these coordinates in the same solution are discussed, and it is indicated that at least five stations are required in the station ensemble.

  15. Concordance among Measurements Obtained by Three Pulse Oximeters Currently Used by Health Professionals

    PubMed Central

    De La Rosa Hormiga, Milagros; MaríA Ramal LóPez, Josefa; DéNiz Rivero, Yasmina; Sandra Marrero Morales, MaríA

    2014-01-01

    Introduction: Oxygen saturation is considered as the 5th vital sign. Presently, there exist fixed and wireless pulse oximeters, being the latter most widely used in the last years. Some of them have no possibility of calibration. This situation leads the health staff to adopt therapeutic attitudes which can be wrong. Therefore, it is extremely important to know if these wireless oximeters show a right concordance as regards measurements, since it is of great interest in daily clinical practice. Objective: To evaluate concordance among measurements obtained by three different pulse oximeters currently used by health professionals. Materials and Methods: This is an observational, descriptive and cross-sectional study related to the concordance of the results obtained in measurements collected by three different pulse oximeters (one monitor and two wireless oximeters) which are available and in use in this hospital unit. The sample size calculation was performed for a concordance above 0.81 and an estimation error which did not exceed 0.20. The intraclass correlation index (ICI) was used to establish the concordance whereas the Landis-Koch criteria were used to interpret the results. Systematic errors were analyzed using the Bland-Altman plot. Results: The overall concordance among the three pulse oximeters analyzed resulted in 0.88, a value considered as “good” according to the Landis-Koch criteria. Conclusion: The results obtained show that in daily clinical practice both wireless pulse oximeters analyzed can be used with a certain reliability, taking into account the limitations of this research. PMID:25302228

  16. Estimating suspended solids concentrations from backscatter intensity measured by acoustic Doppler current profiler in San Francisco Bay, California

    USGS Publications Warehouse

    Gartner, J.W.

    2004-01-01

    The estimation of mass concentration of suspended solids is one of the properties needed to understand the characteristics of sediment transport in bays and estuaries. However, useful measurements or estimates of this property are often problematic when employing the usual methods of determination from collected water samples or optical sensors. Analysis of water samples tends to undersample the highly variable character of suspended solids, and optical sensors often become useless from biological fouling in highly productive regions. Acoustic sensors, such as acoustic Doppler current profilers that are now routinely used to measure water velocity, have been shown to hold promise as a means of quantitatively estimating suspended solids from acoustic backscatter intensity, a parameter used in velocity measurement. To further evaluate application of this technique using commercially available instruments, profiles of suspended solids concentrations are estimated from acoustic backscatter intensity recorded by 1200- and 2400-kHz broadband acoustic Doppler current profilers located at two sites in San Francisco Bay, California. ADCP backscatter intensity is calibrated using optical backscatterance data from an instrument located at a depth close to the ADCP transducers. In addition to losses from spherical spreading and water absorption, calculations of acoustic transmission losses account for attenuation from suspended sediment and correction for nonspherical spreading in the near field of the acoustic transducer. Acoustic estimates of suspended solids consisting of cohesive and noncohesive sediments are found to agree within about 8-10% (of the total range of concentration) to those values estimated by a second optical backscatterance sensor located at a depth further from the ADCP transducers. The success of this approach using commercially available Doppler profilers provides promise that this technique might be appropriate and useful under certain conditions in

  17. Broadband acoustic backscatter and high-resolution morphology of fish: Measurement and modeling

    NASA Astrophysics Data System (ADS)

    Reeder, D. Benjamin; Jech, J. Michael; Stanton, Timothy K.

    2004-08-01

    Broadband acoustic backscattering measurements, advanced high-resolution imaging of fish morphology using CT scans and phase-contrast x rays (in addition to traditional x rays), and associated scattering modeling using the images have been conducted involving alewife (Alosa pseudoharengus), a swimbladder-bearing fish. A greater-than-octave bandwidth (40-95 kHz) signal was used to insonify live, individual, adult alewife that were tethered while being rotated in 1-deg increments over all angles in two planes of rotation (lateral and dorsal/ventral). These data, in addition to providing the orientation dependence of the scattering over a continuous band of frequencies, were also used (after pulse compression) to identify dominant scattering features of the fish (including the skull and swimbladder). The x-ray and CT scan images of the swimbladder were digitized and incorporated into two scattering models: (1) Kirchhoff-ray mode (KRM) model [Clay and Horne, J. Acoust. Soc. Am. 96, 1661-1668 (1994)] and (2) conformal-mapping-based Fourier matching method (FMM), which has recently been extended to finite-length bodies [Reeder and Stanton, J. Acoust. Soc. Am. 116. 729-746 (2004)]. Comparisons between the scattering predictions and data demonstrate the utility of the CT scan imagery for use in scattering models, as it provided a means for rapidly and noninvasively measuring the fish morphology in three dimensions and at high resolution. In addition to further validation of the KRM model, the potential of the new FMM formulation was demonstrated, which is a versatile approach, valid over a wide range of shapes, all frequencies and all angles of orientation.

  18. A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.

    PubMed

    Morris, Paul; Hurrell, Andrew; Shaw, Adam; Zhang, Edward; Beard, Paul

    2009-06-01

    A dual sensing fiber-optic hydrophone that can make simultaneous measurements of acoustic pressure and temperature at the same location has been developed for characterizing ultrasound fields and ultrasound-induced heating. The transduction mechanism is based on the detection of acoustically- and thermally-induced thickness changes in a polymer film Fabry-Perot interferometer deposited at the tip of a single mode optical fiber. The sensor provides a peak noise-equivalent pressure of 15 kPa (at 5 MHz, over a 20 MHz measurement bandwidth), an acoustic bandwidth of 50 MHz, and an optically defined element size of 10 microm. As well as measuring acoustic pressure, temperature changes up to 70 degrees C can be measured, with a resolution of 0.34 degrees C. To evaluate the thermal measurement capability of the sensor, measurements were made at the focus of a high-intensity focused ultrasound (HIFU) field in a tissue mimicking phantom. These showed that the sensor is not susceptible to viscous heating, is able to withstand high intensity fields, and can simultaneously acquire acoustic waveforms while monitoring induced temperature rises. These attributes, along with flexibility, small physical size (OD approximately 150 microm), immunity to Electro-Magnetic Interference (EMI), and low sensor cost, suggest that this type of hydrophone may provide a practical alternative to piezoelectric based hydrophones.

  19. Heat flux measured acoustically at Grotto Vent, a hydrothermal vent cluster on the Endeavour Segment, Juan de Fuca Ridge

    NASA Astrophysics Data System (ADS)

    Xu, G.; Jackson, D. R.; Bemis, K. G.; Rona, P. A.

    2013-12-01

    Over the past several decades, quantifying the heat output has been a unanimous focus of studies at hydrothermal vent fields discovered around the global ocean. Despite their importance, direct measurements of hydrothermal heat flux are very limited due to the remoteness of most vent sites and the complexity of hydrothermal venting. Moreover, almost all the heat flux measurements made to date are snapshots and provide little information on the temporal variation that is expected from the dynamic nature of a hydrothermal system. The Cabled Observatory Vent Imaging Sonar (COVIS, https://sites.google.com/a/uw.edu/covis/) is currently connected to the Endeavour node of the NEPTUNE Canada observatory network (http://www.neptunecanada.ca) to monitor the hydrothermal plumes issuing from a vent cluster (Grotto) on the Endeavour Segment of the Juan de Fuca Ridge. COVIS is acquiring a long-term (20-months to date) time series of the vertical flow rate and volume flux of the hydrothermal plume above Grotto through the Doppler analysis of the acoustic backscatter data (Xu et al., 2013). We then estimate the plume heat flux from vertical flow rate and volume flux using our newly developed inverse method. In this presentation, we will briefly summarize the derivation of the inverse method and present the heat-flux time series obtained consequently with uncertainty quantification. In addition, we compare our heat-flux estimates with the one estimated from the plume in-situ temperatures measured using a Remotely Operative Vehicle (ROV) in 2012. Such comparison sheds light on the uncertainty of our heat flux estimation. Xu, G., Jackson, D., Bemis, K., and Rona, P., 2013, Observations of the volume flux of a seafloor hydrothermal plume using an acoustic imaging sonar, Geochemistry, Geophysics Geosystems, 2013 (in press).

  20. Spectral induced polarization of disseminated electronic conductors: laboratory data obtained through time domain measurements

    NASA Astrophysics Data System (ADS)

    Gurin, G.; Ilyin, Yu.; Tarasov, A.; Titov, K.

    2012-04-01

    With a time domain (TD) technique, we measured Spectral Induced Polarization responses of 19 models of ore. The models were mixtures of calibrated sand (0.2 - 0.3 mm) with calibrated electron-conductive grains (average radii: 0.045, 0.055, 0.13, 0.20, 0.38 and 0.50 mm). The grains represent a mixture of pyrrhotite (30 %), pyrite (30 %), magnetite (30 %) and chalcopyrite (10 %). In the models the grain concentration varied from 0.6 to 30 % by volume. We measured IP decay with a conventional TD measuring setup and a lab low-current transmitter in the time range from 0.3 ms to 64 s. The IP decays obtained with various current wavelength forms were inverted on the basis of the Debye decomposition, which allowed obtaining the relaxation time distribution. The following results were obtained: The total chargeability, m, was found to be independent of the grain size; it is related to the grain fraction, χ, according to the power law, m=6.28.10-2.χ0.78(m is dimensionless, and χ is in per cents; R2=0.98); The grain size, r, was found to be closely related to the mean IP relaxation time, τ, according to the square law, r2=10-5.τ (r is in meters, and τ is in seconds; R2=0.74); the square law corresponds to the diffusion kinetics, but contains the unrealistically large value of the diffusion coefficient; The maximum values of the relaxation time distributions, Zmax, was found to be closely related to the specific surface of the grains, Sv, according to the power law, Zmax=1.82 10-2 Sv0.65 (Zmax is dimensionless, and Sv is in cm-1; R2=0.94); The relaxation time distribution for disseminated ores can be safely recovered on the basis of TD measurements with relatively short pulse lengths (or using frequency domain measurements with relatively high frequency values).

  1. Corneal Topographic and Aberrometric Measurements Obtained with a Multidiagnostic Device in Healthy Eyes: Intrasession Repeatability

    PubMed Central

    López-Navarro, Alberto; Cabezos, Inmaculada; de Fez, Dolores; Caballero, María T.; Camps, Vicent J.

    2017-01-01

    Purpose. To evaluate the intrasession repeatability of corneal curvature, eccentricity, and aberrometric measurements obtained with a multidiagnostic device in healthy eyes. Methods. This study enrolled 107 eyes of 107 patients ranging in age from 23 to 65 years. All of them underwent a complete anterior segment examination with the VX120 system (Visionix-Luneau Technologies, Chartres, France). Three consecutive measurements were obtained. The within-subject standard deviation (Sw), intrasubject precision (1.96 × Sw), and intraclass correlation coefficient (ICC) were calculated. Results. All Sw for corneal power measurements were below 0.26 D, with ICC above 0.982. The Sw for corneal astigmatism at different areas (3, 5, and 7 mm) was below 0.21 D, with ICC above 0.913. Concerning the axis of astigmatism, its Sw was below 11.27°, with ICC above 0.975. The Sw and ICC for corneal eccentricity were 0.067 and 0.957, respectively. The Sw and ICC for high-order aberration root mean square (RMS) were 0.048 µm and 0.901, respectively. For 3rd- and 4th-order aberrometric parameters, all Sw were below 0.037 µm and all ICC were higher than 0.84, except for quadrafoil RMS (ICC: 0.689). Conclusions. The multidiagnostic device evaluated is able to provide consistent measurements of corneal power, eccentricity, and third- and fourth-order aberrations in healthy eyes. PMID:28133542

  2. A comparison of the acoustic and aerodynamic measurements of a model rotor tested in two anechoic wind tunnels

    NASA Technical Reports Server (NTRS)

    Boxwell, D. A.; Schmitz, F. H.; Splettstoesser, W. R.; Schultz, K. J.; Lewy, S.; Caplot, M.

    1986-01-01

    Two aeroacoustic facilities--the CEPRA 19 in France and the DNW in the Netherlands--are compared. The two facilities have unique acoustic characteristics that make them appropriate for acoustic testing of model-scale helicopter rotors. An identical pressure-instrumented model-scale rotor was tested in each facility and acoustic test results are compared with full-scale-rotor test results. Blade surface pressures measured in both tunnels were used to correlated nominal rotor operating conditions in each tunnel, and also used to assess the steadiness of the rotor in each tunnel's flow. In-the-flow rotor acoustic signatures at moderate forward speeds (35-50 m/sec) are presented for each facility and discussed in relation to the differences in tunnel geometries and aeroacoustic characteristics. Both reports are presented in appendices to this paper. ;.);

  3. COMPARISON OF RADIOGRAPHIC MEASUREMENTS OBTAINED WITH CONVENTIONAL AND INDIRECT DIGITAL IMAGING DURING ENDODONTIC TREATMENT

    PubMed Central

    Schmitd, Ligia Buloto; Lima, Tatiana de Castro; Chinellato, Luiz Eduardo Montenegro; Bramante, Clóvis Monteiro; Garcia, Roberto Brandão; de Moraes, Ivaldo Gomes; Bernardineli, Norberti

    2008-01-01

    The aims of this study were to evaluate the quality of indirect digitized radiographic images taken during endodontic procedures and to compare the measurements recorded with this technique to those obtained from conventional radiographs. Two-hundred conventional periapical radiographs taken at the undergraduate Endodontics Clinic of the Dental School of Bauru were digitized. The conventional and indirect digitized images were compared by three examiners as to the quality and accuracy of the measurements recorded during endodontic treatment, in canal length determination, gutta-percha adaptation, lateral condensation and final obturation. The conventional radiographs were observed on a film viewer, surrounded by a dark card, and measured with magnifying glass and a millimeter ruler; the indirect digitized images were evaluated on the Digora® for Windows software, with free utilization of the bright/contrast tool. Unlike the conventional radiographic images, all indirect digitized images were considered as having a high quality. The distance between the filling material and the root apex was 0.117 mm larger, on average, for the Digora® system (p<0.01). The measurements achieved by the investigated radiographic methods were clinically similar and they are thus equivalent. Changes in brightness and contrast of the images using Digora® software improved the diagnosis. PMID:19089211

  4. High Accuracy Acoustic Relative Humidity Measurement in Duct Flow with Air

    PubMed Central

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments. PMID:22163610

  5. Photo-acoustic measurements of gas and aerosol absorption with diode lasers.

    PubMed

    Ponomarev, Yu N

    2004-12-01

    The results of designing multipurpose high-sensitive photo-acoustic (PA) detectors and their application to high-resolution diode laser spectroscopy of molecular gases, gas analysis, and aerosol absorption measurements are summarized in this paper. The hardware and software of the diode laser spectrometer with a Helmholtz resonant PA detector providing an absorption sensitivity limit of better than 10(-7)Wm(-1)Hz(-1/2) are described. A procedure is proposed for an experiment involving the measurements of the rotational structure of hot vibrational bands of molecules. The results of the application of the nonresonant PA cell with temporal resolution of signals to measurements of weak nonresonant absorption of gases and soot aerosols are presented, and the possibility of creating a broad-band PA laser diode aerosol-meter is discussed.

  6. Acoustic Mode Measurements in the Inlet of a Model Turbofan Using a Continuously Rotating Rake

    NASA Technical Reports Server (NTRS)

    Heidelberg, Laurence J.; Hall, David G.

    1992-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  7. Acoustic mode measurements in the inlet of a model turbofan using a continuously rotating rake

    NASA Astrophysics Data System (ADS)

    Heidelberg, Laurence J.; Hall, David G.

    1993-01-01

    Comprehensive measurements of the spinning acoustic mode structure in the inlet of the Advanced Ducted Propeller (ADP) have been completed. These measurements were taken using a unique and previously untried method which was first proposed by T.G. Sofrin. A continuously rotating microphone system was employed. The ADP model was designed and built by Pratt & Whitney and tested in the NASA Lewis 9- by 15-foot Anechoic Wind Tunnel. Three inlet configurations were tested with cut-on and cutoff stator vane sets. The cutoff stator was designed to suppress all modes at the blade passing frequency. Rotating rake measurements indicate that several extraneous circumferential modes were active. The mode orders suggest that their source was an interaction between the rotor and small interruptions in the casing tip treatment. The cut-on stator produced the expected circumferential modes plus higher levels of the unexpected modes seen with the cutoff stator.

  8. Acoustic predictions using measured pressures from a model rotor in the DNW

    NASA Technical Reports Server (NTRS)

    Visintainer, Joseph A.; Burley, Casey L.; Marcolini, Michael A.; Liu, Sandy R.

    1991-01-01

    A contemporary design, 4-bladed United Technologies model rotor with pressure-instrumented blades was tested in the Duits-Nederslandse Windtunnel. Simultaneous acoustic and pressure measurements were made for a wide range of operating conditions. Microphones were optimally positioned at a number of locations in the flow forward of the rotor to measure rotor thickness noise, high-speed impulsive noise (both in the rotor plane), and blade-vortex interaction noise (forward and 25 deg below the rotor plane). The blade surface pressure data are used as aerodynamic input to WOPWOP, which is a state-of-the-art rotor noise prediction program that predicts rotor thickness and loading noise. The predicted results using WOPWOP are compared to the measured noise levels for cases where either thickness noise, blade-vortex interaction noise, or high-speed impulsive noise is the dominant noise mechanism. The comparisons show regions of good agreement, as well as areas where further improvement is necessary.

  9. Measurement of Elastic Properties of Tissue by Shear Wave Propagation Generated by Acoustic Radiation Force

    NASA Astrophysics Data System (ADS)

    Tabaru, Marie; Azuma, Takashi; Hashiba, Kunio

    2010-07-01

    Acoustic radiation force (ARF) imaging has been developed as a novel elastography technology to diagnose hepatic disease and breast cancer. The accuracy of shear wave speed estimation, which is one of the applications of ARF elastography, is studied. The Young's moduli of pig liver and foie gras samples estimated from the shear wave speed were compared with those measured the static Young's modulus measurement. The difference in the two methods was 8%. Distance attenuation characteristics of the shear wave were also studied using finite element method (FEM) analysis. We found that the differences in the axial and lateral beam widths in pressure and ARF are 16 and 9% at F-number=0.9. We studied the relationship between two branch points in distance attenuation characteristics and the shape of ARF. We found that the maximum measurable length to estimate shear wave speed for one ARF excitation was 8 mm.

  10. Measurement of Elastic Properties of Tissue by Shear Wave Propagation Generated by Acoustic Radiation Force

    NASA Astrophysics Data System (ADS)

    Marie Tabaru,; Takashi Azuma,; Kunio Hashiba,

    2010-07-01

    Acoustic radiation force (ARF) imaging has been developed as a novel elastography technology to diagnose hepatic disease and breast cancer. The accuracy of shear wave speed estimation, which is one of the applications of ARF elastography, is studied. The Young’s moduli of pig liver and foie gras samples estimated from the shear wave speed were compared with those measured the static Young’s modulus measurement. The difference in the two methods was 8%. Distance attenuation characteristics of the shear wave were also studied using finite element method (FEM) analysis. We found that the differences in the axial and lateral beam widths in pressure and ARF are 16 and 9% at F-number=0.9. We studied the relationship between two branch points in distance attenuation characteristics and the shape of ARF. We found that the maximum measurable length to estimate shear wave speed for one ARF excitation was 8 mm.

  11. Real-time measurement of electron beam weld penetration in uranium by acoustic emission monitoring

    SciTech Connect

    Whittaker, J.W.; Murphy, J.L.

    1991-07-01

    High quality electron beam (EB) welds are required in uranium test articles. Acoustic emission (AE) techniques are under development with the goal of measuring weld penetration in real-time. One technique, based on Average Signal Level (ASL) measurement was used to record weld AE signatures. Characteristic AE signatures were recorded for bead-on-plate (BOP) and butt joint (BJ) welds made under varied welding conditions. AE waveforms were sampled to determine what microscopic AE behavior led to the observed macroscopic signature features. Deformation twinning and weld expulsion are two of the main sources of emission. AE behavior was correlated with weld penetration as measured by standard metallographic techniques. The ASL value was found to increase approximately linearly with weld penetration in BJ welds. These results form the basis for a real-time monitoring technique for weld penetration. 5 refs.

  12. An acoustic range for the measurement of the noise signature of aircraft during flyby operations

    NASA Technical Reports Server (NTRS)

    Hilton, D. A.; Henderson, H. R.

    1978-01-01

    The remotely operated multiple array acoustic range (ROMAAR), which has been developed to give direct measurement and display of aircraft noise in several measurement units during takeoff, landing, and flyby operations, is described. The ROMAAR, which provides information on the ground noise signature of aircraft, represents a unique combination of state-of-the-art digital and analog noise-recording methods, computer-controlled digital communication methods, radar tracking facilities, quick-look weather (profile) capabilities, and sophisticated data handling routines and facilities. The ROMAAR, which is operated by NASA, allows direct data feedback to the NASA Aircraft Noise Prediction Office. As many as 38 simultaneous noise measurements can be made for each aircraft overflight.

  13. High accuracy acoustic relative humidity measurement in duct flow with air.

    PubMed

    van Schaik, Wilhelm; Grooten, Mart; Wernaart, Twan; van der Geld, Cees

    2010-01-01

    An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

  14. Method and apparatus for background signal reduction in opto-acoustic absorption measurement

    NASA Technical Reports Server (NTRS)

    Rosengren, L. G. (Inventor)

    1976-01-01

    The sensitivity of an opto-acoustic absorption detector is increased to make it possible to measure trace amounts of constituent gases. A second beam radiation path is created through the sample cell identical to a first path except as to length, alternating the beam through the two paths and minimizing the detected pressure difference for the two paths while the beam wavelength is tuned away from the absorption lines of the sample. Then with the beam wavelength tuned to the absorption line of any constituent of interest, the pressure difference is a measure of trace amounts of the constituent. The same improved detector may also be used for measuring the absorption coefficient of known concentrations of absorbing gases.

  15. Use of an Acoustic Doppler Current Profiler (ADCP) to Measure Hypersaline Bidirectional Discharge

    USGS Publications Warehouse

    Johnson, K.K.; Loving, B.L.; ,

    2002-01-01

    The U.S. Geological Survey measures the exchange of flow between the north and south parts of Great Salt Lake, Utah, as part of a monitoring program. Turbidity and bidirectional flow through the breach in the causeway that divides the lake into two parts makes it difficult to measure discharge with conventional streamflow techniques. An acoustic Doppler current profiler (ADCP) can be used to more accurately define the angles of flow and the location of the interface between the layers of flow. Because of the high salinity levels measured in Great Salt Lake (60-280 parts per thousand), special methods had to be developed to adjust ADCP-computed discharges for the increased speed of sound in hypersaline waters and for water entrained at the interface between flow layers.

  16. Picosecond acoustics in vegetal cells: non-invasive in vitro measurements at a sub-cell scale.

    PubMed

    Audoin, B; Rossignol, C; Chigarev, N; Ducousso, M; Forget, G; Guillemot, F; Durrieu, M C

    2010-02-01

    A 100 fs laser pulse passes through a single transparent cell and is absorbed at the surface of a metallic substrate. Picosecond acoustic waves are generated and propagate through the cell in contact with the metal. Interaction of the high frequency acoustic pulse with a probe laser light gives rise to Brillouin oscillations. The measurements are thus made with lasers for both the opto-acoustic generation and the acousto-optic detection, and acoustic frequencies as high as 11 GHz can be detected, as reported in this paper. The technique offers perspectives for single cell imaging. The in-plane resolution is limited by the pump and probe spot sizes, i.e. approximately 1 microm, and the in-depth resolution is provided by the acoustic frequencies, typically in the GHz range. The effect of the technique on cell safety is discussed. Experiments achieved in vegetal cells illustrate the reproducibility and sensitivity of the measurements. The acoustic responses of cell organelles are significantly different. The results support the potentialities of the hypersonic non-invasive technique in the fields of bio-engineering and medicine.

  17. Measuring elastic properties of cells by evaluation of scanning acoustic microscopy V(Z) values using simplex algorithm

    PubMed Central

    Kundu, T.; Bereiter-Hahn, J.; Hillmann, K.

    1991-01-01

    In this paper a new technique is proposed to determine the acoustic properties as well as the thickness (and volume) of biological cells. Variations of thickness, density, acoustic wave velocity, stiffness, and attenuation coefficient of a living or dead cell are obtained by scanning the cell by an acoustic microscope. The distance between the cell and the microscope lens is varied and several voltage curves are thus obtained. These curves are then inverted by simplex optimization technique to obtain the cell parameters. The spatial resolution of the method is limited to the resolution of the scanning acoustic microscope. It allows to take advantage of the full range of frequencies and amplification of the microscope. Characteristic distributions of stiffness are exemplified with an endothelial cell in culture. The main part of the thin, lamellar cytoplasm has high stiffness, which drops close to the lamella/cell body transition region and only slightly increases again through the central part of the cell. Acoustic attenuation seems to be related to two factors, cytoplasm accumulation (in the lamellar parts) and scattering in the central part rich in organelles. ImagesFIGURE 10 PMID:19431793

  18. Noninvasive Measurement of Acoustic Properties of Fluids Using Ultrasonic Interferometry Technique

    SciTech Connect

    Han, W.; Sinha, D.N.; Springer, K.N.; Lizon, D.C.

    1997-06-15

    A swept-frequency ultrasonic interferometry technique is used for noninvasively determining acoustic properties of fluids inside containers. Measurements over a frequency range 1-15 MHz on six liquid chemicals are presented. Measurements were made with the liquid inside standard rectangular optical glass cells and stainless steel cylindrical shells. A theoretical model based on one-dimensional planar acoustic wave propagation through multi-layered media is employed for the interpretation of the observed resonance (interference) spectrum. Two analytical methods, derived from the transmission model are used for determination of sound speed, sound attenuation coefficient, and density of liquids from the relative amplitude and half-power peak width of the observed resonance peaks. Effects of the container material and geometrical properties, path-length, wall thickness are also studied. This study shows that the interferometry technique and the experimental method developed are capable of accurate determination of sound speed, sound attenuation, and density in fluids completely noninvasively. It is a capable and versatile fluid characterization technique and has many potential NDE applications.

  19. Acoustic Monitor for Liquid-Solid Slurries Measurements at Low Weight Fractions

    SciTech Connect

    Tavlarides, Lawrence L.

    2005-06-01

    Our effort in this project is to develop an acoustic monitor for accurate, real-time characterization of the size and weight fractions of solids in slurries for process monitoring and to determine the optimal timing for slurry transfers. This capability will be valuable in the Savannah River Site accelerated clean-up program. Our scientific work during the first research period developed a theory, supported by experiments, to describe sound attenuation of solids in suspensions in the presence of bubbles, which permits us to determine the solid-liquid weight percent. Engineering developments during the second research period led to the design, construction, and demonstration, in our laboratories, of the Syracuse Acoustic Monitor (SAM) system that measures weight percent solids accurately in slurries of 0.5 to 8.0 weight percent on-line and in real-time. Also, we had shown the potential for these measurements in solid-gas-liquid slurries by removing the interference due to the presence of gas bubbles.

  20. Comparison of multifrequency acoustic and in situ measurements of zooplankton abundances in Knight Inlet, British Columbia.

    PubMed

    Trevorrow, Mark V; Mackas, David L; Benfield, Mark C

    2005-06-01

    An investigation of midwater zooplankton aggregations in a coastal fjord was conducted in November 2002. This study focused on quantitative comparisons between a calibrated, three-frequency (38, 120, and 200 kHz) vessel-based echo-sounder, a multinet towed zooplankton sampler (BIONESS), and a high-resolution underwater camera (ZOOVIS). Daytime layers of euphausiids and amphipods near 70-90-m depth were observed in lower parts of the inlet, especially concentrated by tidal flows around a sill. Quantitative backscatter measurements of euphausiids and amphipods, combined with in situ size and abundance estimates, and using an assumed tilt-angle distribution, were in agreement with averaged fluid-cylinder scattering models produced by Stanton and Chu [ICES J. Mar. Sci. 57, 793-807, (2000)]. Acoustic measurements of physonect siphonophores in the upper inlet were found to have a strong 38-kHz scattering strength, in agreement with a damped bubble scattering model using a diameter of 0.4 mm. In relatively dense euphausiid layers, ZOOVIS abundance estimates were found to be a factor of 2 to 4 higher than the acoustic estimates, potentially due to deviations from assumed euphausiid orientation. Nocturnal near-surface euphausiid scattering exhibited a strong (15 dB) and rapid (seconds) sensitivity to vessel lights, interpreted as due to changing animal orientation.

  1. Relative activity of cholesterol in OPPC/cholesterol/sphingomyelin mixtures measured with an acoustic sensor.

    PubMed

    Melzak, Kathryn A; Gizeli, Electra

    2009-03-01

    Acoustic devices are sensitive to the mole fraction of cholesterol present in liposomes adsorbed to the device surface as a result of the different mechanical properties of the liposomes. This fact was exploited to develop an acoustic assay to determine the relative affinity of cholesterol for different lipid mixtures. In the assay described here, the initial rate of beta-cyclodextrin-induced removal of cholesterol was measured for liposomes having a range of compositions. The initial rate of cholesterol removal was found to be directly proportional to the concentration of beta-cyclodextrin (betaCD) present over the range of 0-7.5 mg/ml (0-6.6 mM), consistent with other assays measuring the betaCD-accelerated transfer of cholesterol between liposomes. The affinity of cholesterol for 1-oleoyl-2-palmitoyl-sn-glycero-3-phosphocholine (OPPC) liposomes with a sphingomyelin mole fraction, chi(SPM), of 0.2 was found to be 1.4x higher than that for pure OPPC liposomes. For liposomes composed only of OPPC and cholesterol in varying ratios, the initial rate of cholesterol removal was determined as a function of cholesterol mole fraction (chi(C)). The initial rate of removal showed an increase at chi(C) = 0.13, consistent with phase diagrams showing the start of liquid ordered domain formation, but no such increase at chi(C) = 0.25, in contrast to the predictions of the umbrella model for OPPC/cholesterol interactions.

  2. Measurement of surface acoustic wave velocity using a variable-line-focus polyurea thin-film ultrasonic transducer.

    PubMed

    Aoyagi, Takahiro; Nakazawa, Marie; Tabaru, Masaya; Nakamura, Kentaro; Ueha, Sadayuki

    2009-08-01

    This paper presents the novel measurement method of the surface acoustic wave velocity by the variable-line- focus transducer using a polyurea piezoelectric ultrasonic transducer. First, a multiresonant polyurea thin-film ultrasonic transducer is fabricated by the vapor deposition polymerization process using 2 monomers. Second, the measurement system of surface acoustic wave velocity modified from the V(z) curve method is established. The system uses the fabricated polyurea thin film as a variable-line-focus transducer at the 30-MHz resonance frequency. The focal length is changed by varying the radius of curvature of the film transducer. To estimate the surface acoustic wave velocities from the measured data theoretically, the photographs of the transducer bent shapes are taken by using a digital microscope, and the bent transducer curvature is modeled by the 7th-order polynomial. To examine the performances of the variable-line-focus transducer, the surface acoustic wave velocities of an aluminum and a synthesized silica glass specimen have been measured. The measured surface acoustic velocities showed good agreement with the reference values.

  3. Measurements of Ground Acoustic Environments for Small Solid Rocket Motor Firings

    NASA Technical Reports Server (NTRS)

    Vu, Bruce; Plotkin, Ken

    2011-01-01

    Mobile launcher deck and tower are exposed to severe acoustic environments during launch. These environments, if not properly managed, can weaken ground support equipment and result in structure failure. The objectives of this study were: (1) Characterize the acoustic ground environment with and without water suppression systems. (2) Validate the ground acoustic prediction based on scaling of Saturn V data. and (3) Validate a semi-empirical acoustic analysis.

  4. Acoustic Barrier Facilitates Inlet Noise Measurements for Aft-Dominated Fans

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Noise levels for modern high-bypass-ratio subsonic turbofans tend to be aft dominated. That is, the highest flyover noise levels radiate from the fan exit. Measuring fan inlet sound radiation without aft radiation contamination requires selective suppression of the aft noise. In NASA Lewis Research Center's 9- by 15-Foot Low-Speed Wind Tunnel, an acoustic barrier was used to effectively isolate the inlet noise field for a model of an advanced turbofan. This proof-of-concept test was performed on a model turbofan manufactured for NASA Lewis by the Allison Engine Company as part of the Advanced Subsonic Technology program. The 8-cm-thick acoustic barrier was constructed in sections that were joined upon installation. These sections, which were composed of a wood frame with typically 0.64-cm tempered fiberboard skins, extended from the tunnel's floor to its ceiling and had an axial length of 61 cm. On the fan side of the barrier just downstream of the leading edge, the upstream section had an acoustic treatment--a bulk absorber with a perforated metal skin. It had a nominal full height and an axial length of 46 cm. In addition, an elliptical leading edge was faired into the upstream barrier section. The barrier was mounted on tracks on the tunnel floor and ceiling at a sideline distance of 15 cm from the fan nacelle. Tests were made with the barrier leading edge at the fan inlet highlight plane and 15 cm further aft. The barrier extended downstream essentially to the end of the treated tunnel test section.

  5. Spatial and temporal variability of zooplankton off New Caledonia (Southwestern Pacific) from acoustics and net measurements

    NASA Astrophysics Data System (ADS)

    Smeti, Houssem; Pagano, Marc; Menkes, Christophe; Lebourges-Dhaussy, Anne; Hunt, Brian P. V.; Allain, Valerie; Rodier, Martine; de Boissieu, Florian; Kestenare, Elodie; Sammari, Cherif

    2015-04-01

    Spatial and temporal distribution of zooplankton off New Caledonia in the eastern Coral Sea was studied during two multidisciplinary cruises in 2011, during the cool and the hot seasons. Acoustic measurements of zooplankton were made using a shipborne acoustic Doppler current profiler (S-ADCP), a scientific echosounder and a Tracor acoustic profiling system (TAPS). Relative backscatter from ADCP was converted to biomass estimates using zooplankton weights from net-samples collected during the cruises. Zooplankton biomass was estimated using four methods: weighing, digital imaging (ZooScan), ADCP and TAPS. Significant correlations were found between the different biomass estimators and between the backscatters of the ADCP and the echosounder. There was a consistent diel pattern in ADCP derived biomass and echosounder backscatter resulting from the diel vertical migration (DVM) of zooplankton. Higher DVM amplitudes were associated with higher abundance of small zooplankton and cold waters to the south of the study area, while lower DVM amplitudes in the north were associated with warmer waters and higher abundance of large organisms. Zooplankton was largely dominated by copepods (71-73%) among which calanoids prevailed (40-42%), with Paracalanus spp. as the dominant species (16-17%). Overall, zooplankton exhibited low abundance and biomass (mean night dry biomass of 4.7 ± 2.2 mg m3 during the cool season and 2.4 ± 0.4 mg m3 during the hot season) but high richness and diversity (Shannon index ˜4). Substantially enhanced biomass and abundance appeared to be episodically associated with mesoscale features contributing to shape a rather patchy zooplankton distribution.

  6. A method for obtaining distributed surface flux measurements in complex terrain

    NASA Astrophysics Data System (ADS)

    Daniels, M. H.; Pardyjak, E.; Nadeau, D. F.; Barrenetxea, G.; Brutsaert, W. H.; Parlange, M. B.

    2011-12-01

    Sonic anemometers and gas analyzers can be used to measure fluxes of momentum, heat, and moisture over flat terrain, and with the proper corrections, over sloping terrain as well. While this method of obtaining fluxes is currently the most accurate available, the instruments themselves are costly, making installation of many stations impossible for most campaign budgets. Small, commercial automatic weather stations (Sensorscope) are available at a fraction of the cost of sonic anemometers or gas analyzers. Sensorscope stations use slow-response instruments to measure standard meteorological variables, including wind speed and direction, air temperature, humidity, surface skin temperature, and incoming solar radiation. The method presented here makes use of one sonic anemometer and one gas analyzer along with a dozen Sensorscope stations installed throughout the Val Ferret catchment in southern Switzerland in the summers of 2009, 2010 and 2011. Daytime fluxes are calculated using Monin-Obukhov similarity theory in conjunction with the surface energy balance at each Sensorscope station as well as at the location of the sonic anemometer and gas analyzer, where a suite of additional slow-response instruments were co-located. Corrections related to slope angle were made for wind speeds and incoming shortwave radiation measured by the horizontally-mounted cup anemometers and incoming solar radiation sensors respectively. A temperature correction was also applied to account for daytime heating inside the radiation shield on the slow-response temperature/humidity sensors. With these corrections, we find a correlation coefficient of 0.77 between u* derived using Monin-Obukhov similarity theory and that of the sonic anemometer. Calculated versus measured heat fluxes also compare well and local patterns of latent heat flux and measured surface soil moisture are correlated.

  7. Acoustic emission monitoring system

    DOEpatents

    Romrell, Delwin M.

    1977-07-05

    Methods and apparatus for identifying the source location of acoustic emissions generated within an acoustically conductive medium. A plurality of acoustic receivers are communicably coupled to the surface of the medium at a corresponding number of spaced locations. The differences in the reception time of the respective sensors in response to a given acoustic event are measured among various sensor combinations prescribed by the monitoring mode employed. Acoustic reception response encountered subsequent to the reception by a predetermined number of the prescribed sensor combinations are inhibited from being communicated to the processing circuitry, while the time measurements obtained from the prescribed sensor combinations are translated into a position measurement representative of the location on the surface most proximate the source of the emission. The apparatus is programmable to function in six separate and five distinct operating modes employing either two, three or four sensory locations. In its preferred arrangement the apparatus of this invention will re-initiate a monitoring interval if the predetermined number of sensors do not respond to a particular emission within a given time period.

  8. Morphological and Functional Measurements of the Heart Obtained by Magnetic Resonance Imaging in Brazilians

    PubMed Central

    Macedo, Robson; Fernandes, Juliano Lara; Andrade, Solange Souza; Rochitte, Carlos Eduardo; Lima, Kênio Costa; Maciel, Álvaro Campos Cavalcanti; Maciel, Fernanda Cunha; Alves, Geraldo Souza Pinho; Coelho, Otávio Rizzi; Diniz, Rosiane Viana Zuza

    2013-01-01

    Background Still today, measurements used as a reference in the cardiac magnetic resonance imaging have been obtained mainly from studies carried out in North-American and European populations. Objective To obtain measurements of the diastolic diameter, systolic diameter, end diastolic volume, end systolic volume, ejection fraction, and myocardial mass of the left and right ventricles in Brazilians. Methods 54 men and 53 women, with mean age of 43.4 ± 13.1 years, asymptomatic, with no cardiomyopathies, have been subjected to the cardiac magnetic resonance imaging, using a balanced steady state free precession technique. Results The averages and the standard deviations of the parameters for the left ventricle have been: diastolic diameter =4.8 ± 0.5 cm; systolic diameter = 3.0 ± 0.6 cm; end diastolic volume = 128.4 ± 29.6 mL; end systolic volume = 45.2 ± 16.6 mL; ejection fraction = 65.5 ± 6.3%; mass = 95.2 ± 30.8 g. For the right ventricle, they have been: diastolic diameter = 3.9 ± 1.3 cm; systolic diameter = 2.5 ± 0.5 cm; end diastolic volume = 126.5 ± 30.7 mL; end systolic volume = 53.6 ± 18.4 mL; ejection fraction = 58.3 ± 8.0%, and mass = 26.1 ± 6.1 g. The masses and the volumes were significantly greater in the men, except for the end systolic volume of the left ventricle. The ejection fraction of the right ventricle has been significantly greater in the women. There has been a significant and inverted correlation of the systolic volume of the right volume with the progression of the age. Conclusion This study has described, for the first time, cardiac measurements obtained through the cardiac magnetic resonance imaging in Brazilians, asymptomatic, with no cardiomyopathies, showing differences in accordance with gender and age. PMID:23752338

  9. Low-frequency sound speed and attenuation in sandy seabottom from long-range broadband acoustic measurements.

    PubMed

    Wan, Lin; Zhou, Ji-Xun; Rogers, Peter H

    2010-08-01

    A joint China-U.S. underwater acoustics experiment was conducted in the Yellow Sea with a very flat bottom and a strong and sharp thermocline. Broadband explosive sources were deployed both above and below the thermocline along two radial lines up to 57.2 km and a quarter circle with a radius of 34 km. Two inversion schemes are used to obtain the seabottom sound speed. One is based on extracting normal mode depth functions from the cross-spectral density matrix. The other is based on the best match between the calculated and measured modal arrival times for different frequencies. The inverted seabottom sound speed is used as a constraint condition to extract the seabottom sound attenuation by three methods. The first method involves measuring the attenuation coefficients of normal modes. In the second method, the seabottom sound attenuation is estimated by minimizing the difference between the theoretical and measured modal amplitude ratios. The third method is based on finding the best match between the measured and modeled transmission losses (TLs). The resultant seabottom attenuation, averaged over three independent methods, can be expressed as alpha=(0.33+/-0.02)f(1.86+/-0.04)(dB/m kHz) over a frequency range of 80-1000 Hz.

  10. Phased Acoustic Array Measurements of a 5.75 Percent Hybrid Wing Body Aircraft

    NASA Technical Reports Server (NTRS)

    Burnside, Nathan J.; Horne, William C.; Elmer, Kevin R.; Cheng, Rui; Brusniak, Leon

    2016-01-01

    Detailed acoustic measurements of the noise from the leading-edge Krueger flap of a 5.75 percent Hybrid Wing Body (HWB) aircraft model were recently acquired with a traversing phased microphone array in the AEDC NFAC (Arnold Engineering Development Complex, National Full Scale Aerodynamics Complex) 40- by 80-Foot Wind Tunnel at NASA Ames Research Center. The spatial resolution of the array was sufficient to distinguish between individual support brackets over the full-scale frequency range of 100 to 2875 Hertz. For conditions representative of landing and take-off configuration, the noise from the brackets dominated other sources near the leading edge. Inclusion of flight-like brackets for select conditions highlights the importance of including the correct number of leading-edge high-lift device brackets with sufficient scale and fidelity. These measurements will support the development of new predictive models.

  11. Absolute ultrasonic displacement amplitude measurements with a submersible electrostatic acoustic transducer

    NASA Technical Reports Server (NTRS)

    Yost, William T.; Cantrell, John H.

    1992-01-01

    An experimental technique for absolute measurement of ultrasonic wave particle displacement amplitudes in liquids is reported. The technique is capable of measurements over a frequency range of two decades with a sensitivity less than one angstrom. The technique utilizes a previously reported submersible electrostatic acoustic transducer (ESAT) featuring a conductive membrane stretched over a recessed electrode. An uncertainty analysis shows that the displacement amplitude of an ultrasonic plane wave incident on the ESAT can be experimentally determined to better than 2.3-4 percent, depending on frequency, in the frequency range of 0.5-15 MHz. Membranes with lower and more uniform areal densities can improve the accuracy and extend the operation to higher frequencies.

  12. Classification of heart valve single leg separations from acoustic clinical measurements

    SciTech Connect

    Clark, G.A.; Bowman, B.C.; Boruta, N.; Thomas, G.H.; Jones, H.E.; Buhl, M.R.

    1994-05-01

    Our system classifies the condition (intact or single leg separated) of in vivo Bjork-Shiley Convexo-Concave (BSCC) heart valves by processing acoustic measurements of clinical heart valve opening sounds. We use spectral features as inputs to a two-stage classifier, which first classifies individual heart beats, then classifies valves. Performance is measured by probability of detection and probability of false alarm, and by confidence intervals on the probability of correct classification. The novelty of the work lies in the application of advanced techniques to real heart valve data, and extensions of published algorithms that enhance their applicability. We show that even when given a very small number of training samples, the classifier can achieve a probability of correct classification of 100%.

  13. Acoustic isolation vessel for measurement of the background noise in microphones

    NASA Technical Reports Server (NTRS)

    Ngo, Kim C. T.; Zuckerwar, Allan J.

    1993-01-01

    An acoustic isolation vessel has been developed to measure the background noise in microphones. The test microphone is installed in an inner vessel, which is suspended within an outer vessel, and the intervening air space is evacuated to a high vacuum. An analytical expression for the transmission coefficient is derived, based on a five-media model, and compared to experiment. At an isolation vacuum of 5 x 10 exp -6 Torr the experimental transmission coefficient was found to be lower than -155 dB at frequencies ranging from 40 to 1200 Hz. Measurements of the A-weighted noise levels of commercial condenser microphones of four different sizes show good agreement with published values.

  14. Progress on Acoustic Measurements of the Bulk Viscosity of Near-Critical Xenon (BVX)

    NASA Technical Reports Server (NTRS)

    Gillis, Keith A.; Shinder, Iosif I.; Moldover, Michael R.; Zimmerli, Gregory A.

    2004-01-01

    We plan to determine the bulk viscosity of xenon 10 times closer [in reduced temperature tau = (T-Tc)/Tc] to its liquid-vapor critical point than ever before. (Tc is the critical temperature.) To do so, we must measure the dispersion and attenuation of sound at frequencies 1/100 of those used previously. In general, sound attenuation has contributions from the bulk viscosity acting throughout the volume of the xenon as well as contributions from the thermal conductivity and the shear viscosity acting within thin thermoacoustic boundary layers at the interface between the xenon and the solid walls of the resonator. Thus, we can determine the bulk viscosity only when the boundary layer attenuation is small and well understood. We present a comparison of calculations and measurements of sound attenuation in the acoustic boundary layer of xenon near its liquid-vapor critical point.

  15. Development of a novel odor measurement system using gas chromatography with surface acoustic wave sensor.

    PubMed

    Staples, Edward J; Viswanathan, Shekar

    2008-12-01

    This paper describes a novel odor measurement system for creating arrays of virtual chemical sensors with nonoverlapping responses using ultrahigh-speed gas chromatography with a surface acoustic wave sensor (GC/SAW). This GC/SAW system provides high-resolution two-dimensional olfactory images for easy recognition of many complex odors. Separation and quantification of the individual chemicals within an odor is performed in seconds. Using a solid-state mass-sensitive detector, picogram sensitivity, universal nonpolar selectivity, and electronically variable sensitivity are achieved. An integrated vapor preconcentrator coupled with the electronically variable detector allows the system to measure vapor concentrations spanning 6 or more orders of magnitude. The system attributes of high speed, accuracy, and precision provide a cost-effective and complimentary tool for traditional sensory evaluations.

  16. Intercomparison among tropospheric ozone and nitrogen dioxide data obtained by satellite- and ground-based measurements

    NASA Astrophysics Data System (ADS)

    Noguchi, K.; Urita, N.; Ohta, E.; Hayashida, S.; Richter, A.; Burrows, J. P.; Liu, X.; Chance, K.; Ziemke, J. R.

    2005-12-01

    Rapid economical growth and industrial development in East Asian regions are causing serious air pollution. The influence of such air pollution is not limited to a local scale but reaches an intercontinental or hemispheric scale. Satellite-borne observations can monitor the behaviors of air pollutants in a global scale for long periods with a single instrument. In particular, ozone and nitrogen dioxide in the troposphere have a crucial role in air pollution, and many studies have tried to derive those species. Recently, instrumentations and retrieval techniques have made a lot of progress in measurements of tropospheric constituents. However, tropospheric observations from space need careful validation because of difficulties in detecting signals from the lower atmosphere through the middle atmosphere. In the present study, we intercompare the tropospheric ozone and nitrogen dioxide data obtained by satellite- and ground-based measurements in order to validate the satellite measurements. For the validation of tropospheric ozone, we utilize ozonesonde data provided by WOUDC, and three satellite-borne data (Tropospheric Ozone Residual (TOR), Cloud Slicing, and GOME) are intercompared. For nitrogen dioxide, we compare GOME observations with ground-based air monitoring measurements in Japan which are operationally conducted by the Ministry of the Environment Japan. This study demonstrates the validity and potential of those satellite datasets to apply for quantitative analysis of dispersion of air pollutants and their chemical lifetime. Acknowledgments. TOR data is provided by J. Fishman via http://asd-www.larc.nasa.gov/TOR/data.html. The ground observation data of nitrogen dioxide over Japan is provided by National Institute for Environmental Studies (NIES) under the collaboration study with NIES and Nara Women's University.

  17. The influence of radioactive decay on actinide magnetic susceptibility measurements obtained using the Evans method.

    PubMed

    Autillo, Matthieu; Kaden, Peter; Geist, Andreas; Guerin, Laetitia; Moisy, Philippe; Berthon, Claude

    2014-05-14

    In order to explain the higher magnetic susceptibility of some aquo actinide ions than predicted by Hund's rules, the molar magnetic susceptibilities of two americium isotopes ((241)Am and (243)Am) were measured using the Evans method. The results obtained show a growing change in the magnetic susceptibility with α and also a β(-) activity increase in solution. β(-) particle effects appear to be stronger than radicals formed by α particles on the experimental values. The temperature dependence of Am(iii) magnetic susceptibility has been observed but from experiments carried out here, it appears to be difficult to prove whether this effect arises from radicals or β(-). Finally, magnetic susceptibilities of americium recorded in different media (HClO4, HCl, and HNO3) have been compared to alpha and beta emissions' impact.

  18. Impact of lens distortions on strain measurements obtained with 2D digital image correlation

    NASA Astrophysics Data System (ADS)

    Lava, P.; Van Paepegem, W.; Coppieters, S.; De Baere, I.; Wang, Y.; Debruyne, D.

    2013-05-01

    The determination of strain fields based on displacements obtained via digital image correlation (DIC) at the micro-strain level (≤1000 μm/m) is still a cumbersome task. In particular when high-strain gradients are involved, e.g. in composite materials with multidirectional fibre reinforcement, uncertainties in the experimental setup and errors in the derivation of the displacement fields can substantially hamper the strain identification process. In this contribution, the aim is to investigate the impact of lens distortions on strain measurements. To this purpose, we first perform pure rigid body motion experiments, revealing the importance of precise correction of lens distortions. Next, a uni-axial tensile test on a textile composite with spatially varying high strain gradients is performed, resulting in very accurately determined strains along the fibers of the material.

  19. Sixteen-Year Change in Acoustic-Admittance Measures among Older Adults: Data from a Population-Based Study

    ERIC Educational Resources Information Center

    Nondahl, David M.; Cruickshanks, Karen J.; Wiley, Terry L.; Tweed, Ted S.; Dalton, Dayna S.

    2013-01-01

    Purpose: The primary purpose of this study was to measure the 16-year change in peak compensated static acoustic admittance (Peak Y[subscript tm]) in a population-based cohort of older adults, and to determine whether age was associated with any observed change in Peak Y[subscript tm]. Other tympanometric measures also were taken and analyzed.…

  20. Transcranial measurements of the acoustic field produced by a low frequency focused ultrasound system

    NASA Astrophysics Data System (ADS)

    Voie, Arne; Fisher, David; Ahadi, Golnaz; Hölscher, Thilo

    2012-11-01

    The purpose of this study was to ascertain the effects of the skull on the location, shape and power of the acoustic field produced by a 150 mm radius hemispherical array operating at 220 kHz. We wanted to determine whether phase aberrations were significant at this frequency, the amount of attenuation, and whether CT data could be predictive of the trans-skull field. The effects of five calvaria were evaluated. Acoustic field data and CT scans for each skull specimen were imported into MATLAB® for measurements and visualization in two and three dimensions. We examined the effects of skull density, porosity, thickness, and sonication incident angles, and estimated the relative contributions of longitudinal and shear transmission to the total transmitted power. Power transmission through the skulls varied between 4% and 23% (mean: 12%). The range of focal position shifts was from 0.50 mm to 4.32 mm (mean: 1.95 mm). The 3 dB dimensions of the focused ultrasound (FUS) intensity focal volume increased on average by 39% (low: 4%, high: 122%). The 6 dB pressure focal volume increased by an average of 130 ± 75%. In general, the main effects of the skulls were power reduction, field dispersion and slight shift of focal peak location.

  1. Accelerometer measurements of acoustic-to-seismic coupling above buried objects.

    PubMed

    Attenborough, Keith; Qin, Qin; Jefferis, Jonathan; Heald, Gary

    2007-12-01

    The surface velocity of sand inside a large PVC container, induced by the sound pressure from either a large loudspeaker radiating into an inverted cone and pipe or a Bruel and Kjaer point source loudspeaker mounted with its axis vertical, has been measured using accelerometers. Results of white noise and stepped frequency excitation are presented. Without any buried object the mass loading of an accelerometer creates resonances in the spectral ratio of sand surface velocity to incident acoustic pressure, i.e., the acoustic-to-seismic (A/S) admittance spectra. The A/S responses above a buried compliant object are larger and distinctive. The linear A/S admittance spectra in the presence of a buried electronic components box have been studied as a function of burial depth and sand state. The nonlinear responses above the buried box have been studied as a function of depth, sand state, and amplitude. Predictions of a modified one-dimensional lumped parameter model have been found to be consistent with the observed nonlinear responses. Also the modified model has been used to explain features of the A/S responses observed when using an accelerometer without any buried object.

  2. Quantitative measurement of ultrasound pressure field by optical phase contrast method and acoustic holography

    NASA Astrophysics Data System (ADS)

    Oyama, Seiji; Yasuda, Jun; Hanayama, Hiroki; Yoshizawa, Shin; Umemura, Shin-ichiro

    2016-07-01

    A fast and accurate measurement of an ultrasound field with various exposure sequences is necessary to ensure the efficacy and safety of various ultrasound applications in medicine. The most common method used to measure an ultrasound pressure field, that is, hydrophone scanning, requires a long scanning time and potentially disturbs the field. This may limit the efficiency of developing applications of ultrasound. In this study, an optical phase contrast method enabling fast and noninterfering measurements is proposed. In this method, the modulated phase of light caused by the focused ultrasound pressure field is measured. Then, a computed tomography (CT) algorithm used to quantitatively reconstruct a three-dimensional (3D) pressure field is applied. For a high-intensity focused ultrasound field, a new approach that combines the optical phase contrast method and acoustic holography was attempted. First, the optical measurement of focused ultrasound was rapidly performed over the field near a transducer. Second, the nonlinear propagation of the measured ultrasound was simulated. The result of the new approach agreed well with that of the measurement using a hydrophone and was improved from that of the phase contrast method alone with phase unwrapping.

  3. Tree architecture and forest canopy structure obtained from terrestrial LiDAR measurements

    NASA Astrophysics Data System (ADS)

    Hentschel, Reiner; Bittner, Sebastian; Ritter, Daniel; Priesack, Eckart

    2013-04-01

    The modelling of the water transfer in vegetation on a small scale is important when the interaction of single plants and the competition of species are in focus of interest. Explicit geometrical functional-structural models that simulate the water flow in the single plant components such as roots, stem, and branches have been developed recently. These models need an explicit geometrical model of the plant hydrology, more precisely the possible pathway of the xylem and phloem water flow. Roots, stem, and branches are represented by connected porous cylinder elements that are divided into the inner heartwood cylinders surrounded by xylem and phloem. Terrestrial laser scanning (TLS) has been successfully applied to assess the structure of the aboveground vegetation in situ in the last years. Based on the technique of light detection and ranging (LiDAR) this method provides a set of three dimensional points that are located on the surface of objects such as vegetation. A further data processing of this three dimensional point cloud (typically consistent of some million points) enables to obtain structural properties like the spatial leaf distribution or large scale characteristics such as the stand height or plant density. Whereas the resolution and detection rate of the laser scanners have increased in the last years, there is still a need for a data handling especially in the field of ecology. We present the results of a skeleton extraction algorithm that is able to obtain the position and size of branch and stem cylinder elements from a three-dimensional point cloud obtained by TLS field measurements. No manual data processing is necessary to apply the algorithm allowing the analysis of a high number of individual plants. The resulting hydraulic architecture determines the possible pathway of water through the stem and the branches. It can consist of several thousands of connected cylinders depending on the plants that are observed. Examples are given and discussed

  4. Accuracy of cyclosporin measurements made in capillary blood samples obtained by skin puncture.

    PubMed

    Merton, G; Jones, K; Lee, M; Johnston, A; Holt, D W

    2000-10-01

    International consensus guidelines suggest that cyclosporin should be measured in whole blood. In some instances it may be advantageous to collect capillary blood, by a finger or ear prick method. However, drug concentrations in skin-puncture blood may not necessarily correlate with those measured in venous blood. This study compared cyclosporin concentrations in blood collected from the fingertip or earlobe with blood collected by standard venipuncture. Patient preference for each of the blood collection methods was also assessed. Specimens were obtained from organ transplant patients receiving cyclosporin, using each of the three methods: venipuncture, finger prick, and earlobe prick. The samples were assayed using a specific radioimmunoassay and the results were compared. In the 102 sets of samples collected, the mean difference (+/- standard deviation) in cyclosporin concentration between finger prick and venipuncture and ear prick and venipuncture was 2.6% (+/- 9.5%) and 2.7% (+/- 12.1%), respectively, while the comparable median (IQR) differences were 1.9% (-3.4% to +6.6%) and -1.1% (-2.8% to +7.2%), respectively. A high degree of correlation was observed between finger prick and venipuncture or ear prick and venipuncture or ear prick and finger prick (r2 > 0.86). Of the three methods of blood collection, finger prick was the patients' preferred method (P < 0.01). These data suggest that capillary blood collected by skin puncture is suitable for use in cyclosporin blood monitoring and acceptable to patients.

  5. Southern Hemispheric nitrous oxide measurements obtained during 1987 airborne Antarctic ozone experiment

    NASA Technical Reports Server (NTRS)

    Podolske, J. R.; Loewenstein, M.; Strahan, S. E.; Chan, K. Roland

    1988-01-01

    The chemical lifetime of N2O is about 150 years, which makes it an excellent dynamical tracer of air motion on the time scale of the ozone depletion event. For these reasons it was chosen to help test whether dynamical theories of ozone loss over Antarctica were plausible, particularly the theory that upwelling ozone-poor air from the troposphere was replacing ozone-rich stratospheric air. The N2O measurements were made with the Airborne Tunable Laser Absorption Spectrometer (ATLAS) aboard the NASA ER-2 aircraft. The detection technique involves measuring the diffential absorption of the IR laser radiation as it is rapidly scanned over an N2O absorption feature. For the AAOE mission, the instrument was capable of making measurements with a 1 ppb sensitivity, 1 second response time, over an altitude range of 10 to 20 kilometers. The AAOE mission consisted of a series of 12 flights from Punta Arenas (53S) into the polar vortex (approximately 72S) at which time a vertical profile from 65 to 45 km and back was performed. Comparison of the observed profiles inside the vortex with N2O profiles obtained by balloon flights during the austral summer showed that an overall subsidence had occurred during the winter of about 5 to 6 km. Also, over the course of the mission (mid-August to late September), no trend in the N2O vertical profile, either upward or downward, was discernible, eliminating the possibility that upwelling was the cause of the observed ozone decrease.

  6. Tidal harmonics obtained from Dynasonde measurements in the bottom F-Layer

    NASA Astrophysics Data System (ADS)

    Negrea, C.; Bullett, T. W.; Zabotin, N. A.; Fuller-Rowell, T. J.

    2014-12-01

    It is now well accepted that atmospheric tidal waves have a dramatic influence on thermospheric and ionospheric structure and variability. Considerable effort goes into understanding the characteristics of tidal modes, their interactions with planetary and gravity waves and other tidal modes, as well as their influence on the background state of the thermosphere-ionosphere system. For the altitude interval between roughly 120 and 400 km, this effort is somewhat hindered by the lack of global observations. We propose a new method of determining tidal variability by making use of Dynasonde measurements. The NeXtYZ inversion procedure (a part of the Dynasonde software package) produces altitude profiles of the ionospheric parameters with a vertical resolution typically below 1 km. This, together with the 2 minute cadence of the instrument results in extensive datasets with wide temporal and altitude coverage. Because of the natural ionospheric variability, at any given altitude we have non-uniform sampling over extended time intervals. A Lomb-Scargle implementation is used to mitigate this issue, allowing us to obtain both amplitude and phase information in an equivalent manner at all altitudes and locations. In this poster, we provide altitude profiles of the first 3 diurnal harmonics derived from dynasonde measurements. The data analyzed include the truly vertical electron density profiles, the ionospheric X (East-West) "tilt" measurement and the derived zonal plasma density gradient. Both the tilt and the gradient can be shown to be sensitive tracers of atmospheric waves, in some cases more so than the raw electron density. We use data from Wallops Island, VA and San Juan, PR for May and September 2013, thus capturing seasonal, latitudinal and altitude variations of tidal amplitude and phase. This can be used for comparisons with existing theoretical work and also to test propagation of tidal waves in coupled ionosphere-thermosphere models.

  7. Reliability of measurements of hip abduction strength obtained with a hand-held dynamometer.

    PubMed

    Ieiri, Akira; Tushima, Eiki; Ishida, Kazuhiro; Inoue, Masahiro; Kanno, Taiki; Masuda, Takeshi

    2015-02-01

    This study aimed to evaluate intrarater and interrater reliability when measuring hip abductor strength in the supine position using a hand-held dynamometer (HHD) (Study 1), and to elucidate the relationships between measured values and examiners' physical characteristics (Study 2). Three healthy examiners (1 female, 24 y.o. and 2 males 23 and 27 y.o) and 12 subjects (6 females, 24.5 ± 2.8 years and 6 males, 27.7 ± 3.5 years) participated in Study 1, and 20 healthy examiners (7 females, 22.3 ± 1.3 years and 13 males, 29.4 ± 8.2 years) and 2 subjects (1 female, 24 y.o. and 1 male 27 y.o) participated in Study 2. All healthy examiners were hospital employees. Hip abductor strength was measured by HHD with hand fixation and with belt fixation, and examiner age, sex, height, weight, BMI, and dominant hand grip strength were evaluated. The intraclass correlation coefficient (ICC) (1,1), a measure of intrarater reliability, was 0.89-0.95 with hand fixation and 0.96-0.97 with belt fixation. ICC (2,1), a measure of interrater reliability, was 0.76-0.79 and 0.90-0.93, respectively. In subjects with high muscle strength (the examiner's hand was moved), the examiner's dominant hand grip strength affected muscle strength values with hand fixation (standardized partial regression coefficient = 0.78, determination coefficient R(2 )= 0.61, p < 0.01). In subjects with low muscle strength (the examiner's hand was not moved), no variables had effect. When the muscle strength of the subject is weak, both methods can be used. When the muscle strength of the subject is strong, it is necessary to adjust the value obtained by the examiner's dominant hand grip strength in the hand fixation method.

  8. Comparison of Lagrangian and Steady State Box Model Runs With Measurement Data Obtained During GABRIEL

    NASA Astrophysics Data System (ADS)

    Stickler, A.; Fischer, H.; Gurk, C.; Bozem, H.; Schiller, C.; Parchatka, U.; Martinez-Harder, M.; Kubistin, D.; Harder, H.; Williams, J.; Königstedt, R.; Ganzeveld, L.; Lelieveld, J.

    2006-12-01

    Results of a comparison of different Lagrangian and steady state box model runs with measurement data obtained during the GABRIEL campaign over the tropical rainforest in October 2005 (Suriname) are presented and discussed. Lagrangian modelling of boundary layer (BL) CO (0-1 km a.s.l.) constrained by measured O3, methanol, acetone, isoprene, the sum of methacrolein and methyl vinyl ketone, NO, HCHO, H2O2, organic peroxide, OH, HO2, H2O and radiation was used to derive the horizontal gradient (~ 8 pptv/km) of this compound from the ocean to the rainforest (east to west). It is significantly smaller than those derived from the measurements (16-48 pptv/km), indicating that photochemical production from organic precursors alone cannot explain the observed strong gradient. The results were cross- checked with a steady state and a Lagrangian box model study for HCHO. It appears that HCHO is significantly overestimated by the models, which include dry deposition, but not exchange with the free troposphere (FT). Sensitivity runs show that only an unlikely combination of several modified parameters (OH minus 25%, NO minus 5 pptv, Cl minus 75%, vdep = vdep(HNO3)) comes close to the observed values. The relatively short calculated lifetime of HCHO (50-100 min) implies significant BL-FT exchange even on small timescales if heterogeneous loss of HCHO on aerosol particles is considered to be unimportant. The mixing-in from above of FT air affected by biomass burning would increase the CO and lower the HCHO mixing ratios, leading to a better agreement of models and measurements. The deposition velocity for H2O2 over ocean and rainforest is deduced from box model results constrained by HOx and radiation measurements and assuming BL-FT exchange adequate to the results for CO. The Lagrangian model is used to check if the horizontal gradient observed for organic peroxides can be reproduced assuming that their deposition velocity is smaller than that of H2O2. Finally O3 formation

  9. High-Frequency CTD Measurements for Accurate GPS/acoustic Sea-floor Crustal Deformation Measurement System

    NASA Astrophysics Data System (ADS)

    Tadokoro, K.; Yasuda, K.; Taniguchi, S.; Uemura, Y.; Matsuhiro, K.

    2015-12-01

    The GPS/acoustic sea-floor crustal deformation measurement system has developed as a useful tool to observe tectonic deformation especially at subduction zones. One of the factors preventing accurate GPS/acoustic sea-floor crustal deformation measurement is horizontal heterogeneity of sound speed in the ocean. It is therefore necessary to measure the gradient directly from sound speed structure. We report results of high-frequency CTD measurements using Underway CTD (UCTD) in the Kuroshio region. We perform the UCTD measurements on May 2nd, 2015 at two stations (TCA and TOA) above the sea-floor benchmarks installed across the Nankai Trough, off the south-east of Kii Peninsula, middle Japan. The number of measurement points is six at each station along circles with a diameter of 1.8 nautical miles around the sea-floor benchmark. The stations TCA and TOA are located on the edge and the interior of the Kuroshio current, respectively, judging from difference in sea water density measured at the two stations, as well as a satellite image of sea-surface temperature distribution. We detect a sound speed gradient of high speeds in the southern part and low speeds in the northern part at the two stations. At the TCA station, the gradient is noticeable down to 300 m in depth; the maximum difference in sound speed is +/- 5 m/s. The sound speed difference is as small as +/- 1.3 m/s at depths below 300 m, which causes seafloor benchmark positioning error as large as 1 m. At the TOA station, the gradient is extremely small down to 100 m in depth. The maximum difference in sound speed is less than +/- 0.3 m/s that is negligible small for seafloor benchmark positioning error. Clear gradient of high speed is observed to the depths; the maximum difference in sound speed is +/- 0.8-0.9 m/s, causing seafloor benchmark positioning error of several tens centimeters. The UCTD measurement is effective tool to detect sound speed gradient. We establish a method for accurate sea

  10. Block distributions on the lunar surface: A comparison between measurements obtained from surface and orbital photography

    NASA Technical Reports Server (NTRS)

    Cintala, Mark J.; Mcbride, Kathleen M.

    1995-01-01

    Among the hazards that must be negotiated by lunar-landing spacecraft are blocks on the surface of the Moon. Unfortunately, few data exist that can be used to evaluate the threat posed by such blocks to landing spacecraft. Perhaps the best information is that obtained from Surveyor photographs, but those data do not extend to the dimensions of the large blocks that would pose the greatest hazards. Block distributions in the vicinities of the Surveyor 1, 3, 6, and 7 sites have been determined from Lunar Orbiter photography and are presented here. Only large (i.e., greater than or equal to 2.5 m) blocks are measurable in these pictures, resulting in a size gap between the Surveyor and Lunar Orbiter distributions. Nevertheless, the orbital data are self-consistent, a claim supported by the similarity in behavior between the subsets of data from the Surveyor 1, 3, and 6 sites and by the good agreement in position (if not slopes) between the data obtained from the Surveyor 3 photography and those derived from the Lunar Orbiter photographs. Confidence in the results is also justified by the well-behaved distribution of large blocks at the surveyor site. Comparisons between the Surveyor distributions and those derived from the orbital photography permit these observations: (1) in all cases but that for Surveyor 3, the density of large blocks is overestimated by extrapolation of the Surveyor-derived trends; (2) the slopes of the Surveyor-derived distributions are consistently lower than those determined for the large blocks; and (3) these apparent disagreements could be mitigated if the overall shapes of the cumulative lunar block populations were nonlinear, allowing for different slopes over different size intervals. The relatively large gaps between the Surveyor-derived and Orbiter-derived data sets, however, do not permit a determination of those shapes.

  11. Validation of streamflow measurements made with M9 and RiverRay acoustic Doppler current profilers

    USGS Publications Warehouse

    Boldt, Justin A.; Oberg, Kevin A.

    2015-01-01

    The U.S. Geological Survey (USGS) Office of Surface Water (OSW) previously validated the use of Teledyne RD Instruments (TRDI) Rio Grande (in 2007), StreamPro (in 2006), and Broadband (in 1996) acoustic Doppler current profilers (ADCPs) for streamflow (discharge) measurements made by the USGS. Two new ADCPs, the SonTek M9 and the TRDI RiverRay, were first used in the USGS Water Mission Area programs in 2009. Since 2009, the OSW and USGS Water Science Centers (WSCs) have been conducting field measurements as part of their stream-gaging program using these ADCPs. The purpose of this paper is to document the results of USGS OSW analyses for validation of M9 and RiverRay ADCP streamflow measurements. The OSW required each participating WSC to make comparison measurements over the range of operating conditions in which the instruments were used until sufficient measurements were available. The performance of these ADCPs was evaluated for validation and to identify any present and potential problems. Statistical analyses of streamflow measurements indicate that measurements made with the SonTek M9 ADCP using firmware 2.00–3.00 or the TRDI RiverRay ADCP using firmware 44.12–44.15 are unbiased, and therefore, can continue to be used to make streamflow measurements in the USGS stream-gaging program. However, for the M9 ADCP, there are some important issues to be considered in making future measurements. Possible future work may include additional validation of streamflow measurements made with these instruments from other locations in the United States and measurement validation using updated firmware and software.

  12. Measurement of Acoustic Intensity Distribution and Radiation Power of Flat-Plate Phased-Array Sound Source

    NASA Astrophysics Data System (ADS)

    Yokoyama, Tomoki; Takahashi, Kumiko; Seki, Daizaburou; Hasegawa, Akio

    2002-05-01

    The acoustic intensity distribution and radiation power of a flat-plate phased-array sound source consisting of Tonpilz-type transducers were measured. This study shows that the active acoustic intensity is skewed in the direction of wave propagation. In addition, it clarifies that if the measurement is carried out in the immediate vicinity of the sound source, the reactive acoustic intensity distribution is effective for identifying the positions of the individual sound source elements. Experimental values of active radiation power agree well with theoretical values. Conversely, experimental values of reactive radiation power do not agree with theoretical values; it is clear that they fluctuate significantly with distance from the radiating surface. The reason for this is explained in the case of a point sound source.

  13. Hand-Held Dynamometer Measurements Obtained in a Home Environment Are Reliable but Not Correlated Strongly with Function.

    ERIC Educational Resources Information Center

    Bohannon, R. W.

    1996-01-01

    This research report describes the reliability and validity of hand-held dynamometer measurements of knee extension force obtained from 13 patients referred for physical therapy. Results found that hand-held dynamometry can be used to obtain reliable measures of muscle strength; however, correlation between strength measures and function was not…

  14. Acoustic measurements of the 1999 basaltic eruption of Shishaldin volcano, Alaska 1. Origin of Strombolian activity

    USGS Publications Warehouse

    Vergniolle, S.; Boichu, M.; Caplan-Auerbach, J.

    2004-01-01

    The 1999 basaltic eruption of Shishaldin volcano (Alaska, USA) displayed both classical Strombolian activity and an explosive Subplinian plume. Strombolian activity at Shishaldin occurred in two major phases following the Subplinian activity. In this paper, we use acoustic measurements to interpret the Strombolian activity. Acoustic measurements of the two Strombolian phases show a series of explosions that are modeled by the vibration of a large overpressurised cylindrical bubble at the top of the magma column. Results show that the bubble does not burst at its maximum radius, as expected if the liquid film is stretched beyond its elasticity. But bursting occurs after one cycle of vibration, as a consequence of an instability of the air-magma interface close to the bubble minimum radius. During each Strombolian period, estimates of bubble length and overpressure are calculated. Using an alternate method based on acoustic power, we estimate gas velocity to be 30-60 m/s, in very good agreement with synthetic waveforms. Although there is some variation within these parameters, bubble length and overpressure for the first Strombolian phase are found to be ??? 82 ?? 11 m and 0.083 MPa. For the second Strombolian phase, bubble length and overpressure are estimated at 24 ?? 12 m and 0.15 MPa for the first 17 h after which bubble overpressure shows a constant increase, reaching a peak of 1.4 MPa, just prior to the end of the second Strombolian phase. This peak suggests that, at the time, the magma in the conduit may contain a relatively large concentration of small bubbles. Maximum total gas volume and gas fluxes at the surface are estimated to be 3.3 ?? 107 and 2.9 ?? 103 m3/s for the first phase and 1.0 ?? 108 and 2.2 ?? 103 m3/s for the second phase. This gives a mass flux of 1.2 ?? 103 and 8.7 ?? 102 kg/s, respectively, for the first and the second Strombolian phases. ?? 2004 Elsevier B.V. All rights reserved.

  15. Methods for the treatment of acoustic and absorptive/dispersive wave field measurements

    NASA Astrophysics Data System (ADS)

    Innanen, Kristopher Albert Holm

    Many recent methods of seismic wave field processing and inversion concern themselves with the fine detail of the amplitude and phase characteristics of measured events. Processes of absorption and dispersion have a strong impact on both; the impact is particularly deleterious to the effective resolution of images created from the data. There is a need to understand the dissipation of seismic wave energy as it affects such methods. I identify: algorithms based on the inverse scattering series, algorithms based on multiresolution analysis, and algorithms based on the estimation of the order of the singularities of seismic data, as requiring this kind of study. As it turns out, these approaches may be cast such that they deal directly with issues of attenuation, to the point where they can be seen as tools for viscoacoustic forward modelling, Q estimation; viscoacoustic inversion, and/or Q compensation. In this thesis I demonstrate these ideas in turn. The forward scattering series is formulated such that a viscoacoustic wave field is represented as an expansion about an acoustic reference; analysis of the convergence properties and scattering diagrams are carried out, and it is shown that (i) the attenuated wave field may be generated by the nonlinear interplay of acoustic reference fields, and (ii) the cumulative effect of certain scattering types is responsible for macroscopic wave field properties: also, the basic form of the absorptive/dispersive inversion problem is predicted. Following this, the impact of Q on measurements of the local regularity of a seismic trace, via Lipschitz exponents, is discussed, with the aim of using these exponents as a means to estimate local Q values. The problem of inverse scattering based imaging and inversion is treated next: I present a simple, computable form for the simultaneous imaging and wavespeed inversion of 1D acoustic wave field data. This method is applied to 1D, normal incidence synthetic data: its sensitivity with

  16. The effect of two different rooms on acoustical and perceptual measures of SATB choir sound

    NASA Astrophysics Data System (ADS)

    Hom, Kathryn S.

    The purpose of this study was to explore the effect of two different rooms (choir rehearsal room, performance hall) on acoustical (LTAS, one-third octave bands) and perceptual (singer [N = 11] survey, listener [N = 33] survey, Pitch Analyzer 2.1) measures of soprano, alto, tenor, and bass (SATB) choir sound. Primary findings of this investigation indicated: (a) significant differences in spectral energy comparisons of choir sound between rooms, (b) choristers' perceptions of hearing and monitoring their own voices differed significantly depending on room, (c) most choristers (82%) perceived that the choir performed best within the Performance Hall, (d) perceived pitch of selected sung vowels within recordings differed significantly based on room conditions, (e) 97% of listeners perceived a difference in choir sound between room recordings, and (f) most listeners (91%) indicated preference for the Rehearsal Room recording.

  17. Comparison of shipboard acoustic Doppler current profiler and moored current measurements in the Equatorial Pacific

    NASA Technical Reports Server (NTRS)

    Chereskin, T. K.; Regier, L. A.; Halpern, D.

    1987-01-01

    Depth-averaged current shears computed from shipboard acoustic Doppler current profiler (ADCP) and moored Savonius rotor and vane vector-averaging current meter (VACM) measurements are compared at 35, 62.5, 100 and 140 m depths within 7 km of each other near 0 deg, 140 deg W during a 12-day interval in November 1984. The agreement between the VACM and ADCP shears was excellent. The average root-mean-square difference of hourly shear values was small, approximately 0.0021/s, and the average correlation coefficient was 0.90. Spectral estimates were equivalent to within a 95 percent significance level and the VACM and ADCP shears were 95 percent statistically coherent with zero phase difference for frequencies below 0.2 cycles per hour.

  18. Method for Estimating the Acoustic Pressure in Tissues Using Low-Amplitude Measurements in Water.

    PubMed

    Keravnou, Christina P; Izamis, Maria-Louisa; Averkiou, Michalakis A

    2015-11-01

    The aim of this study was to evaluate a simple, reliable and reproducible method for accuracy in estimating the acoustic pressure delivered in tissue exposed to ultrasound. Such a method would be useful for therapeutic applications of ultrasound with microbubbles, for example, sonoporation. The method is based on (i) low-amplitude water measurements that are easily made and do not suffer from non-linear propagation effects, and (ii) the attenuation coefficient of the tissue of interest. The range of validity of the extrapolation method for different attenuation and pressure values was evaluated with a non-linear propagation theoretical model. Depending on the specific tissue attenuation, the method produces good estimates of pressures in excess of 10 MPa. Ex vivo machine-perfused pig liver tissue was used to validate the method for source pressures up to 3.5 MPa. The method can be used to estimate the delivered pressure in vivo in diagnostic and therapeutic applications of ultrasound.

  19. Time series of temperature in Fram Strait determined from the 2008-2009 DAMOCLES acoustic tomography measurements and an ocean model

    NASA Astrophysics Data System (ADS)

    Sagen, Hanne; Dushaw, Brian D.; Skarsoulis, Emmanuel K.; Dumont, Dany; Dzieciuch, Matthew A.; Beszczynska-Möller, Agnieszka

    2016-07-01

    A pilot acoustic tomography program in Fram Strait during 2008-2009 measured a year-long record of acoustic travel times along a 130 km range acoustic path crossing the West Spitsbergen Current. Individual ray arrivals were not observed. Rather, the arrival patterns consisted of a single, stable, broad arrival pulse of about 100 ms duration. Travel time variations of ±0.15 s recorded the vigorous mesoscale environment of the region and the seasonal cycle. To estimate ocean temperature from the tomography data an inverse scheme employed a high-resolution ocean model for Fram Strait as the reference ocean. The information from the tomographic measurements is primarily average temperature. Estimated temperatures, averaged over 0-1000 m depth and over range, had a mean of 1.11°C and variations of ±0.33°C; the uncertainty of the tomography estimates was about 60m°C. Agreement with an alternate inverse approach based on EOFs and a Markov Chain Monte Carlo inversion scheme relying on a matched-peak approach was excellent, indicating a robust estimate for ocean temperature. The inverse estimates for average temperature agreed with the equivalent estimates from hydrographic sections obtained along the acoustic path at the start and end of the program. Among other deficiencies, the ocean model greatly underestimated the intensity of the mesoscale fluctuations and exhibited a warm bias of about 0.38°C in section-averaged temperature. Tomographic measurements in Fram Strait offer unique large-scale temperature constraints for ocean models through data assimilation. It is anticipated that these constraints will lead to more accurate estimates of the circulation and transports in Fram Strait.

  20. Effect of image resolution manipulation in rearfoot angle measurements obtained with photogrammetry.

    PubMed

    Sacco, I C N; Picon, A P; Ribeiro, A P; Sartor, C D; Camargo-Junior, F; Macedo, D O; Mori, E T T; Monte, F; Yamate, G Y; Neves, J G; Kondo, V E; Aliberti, S

    2012-09-01

    The aim of this study was to investigate the influence of image resolution manipulation on the photogrammetric measurement of the rearfoot static angle. The study design was that of a reliability study. We evaluated 19 healthy young adults (11 females and 8 males). The photographs were taken at 1536 pixels in the greatest dimension, resized into four different resolutions (1200, 768, 600, 384 pixels) and analyzed by three equally trained examiners on a 96-pixels per inch (ppi) screen. An experienced physiotherapist marked the anatomic landmarks of rearfoot static angles on two occasions within a 1-week interval. Three different examiners had marked angles on digital pictures. The systematic error and the smallest detectable difference were calculated from the angle values between the image resolutions and times of evaluation. Different resolutions were compared by analysis of variance. Inter- and intra-examiner reliability was calculated by intra-class correlation coefficients (ICC). The rearfoot static angles obtained by the examiners in each resolution were not different (P > 0.05); however, the higher the image resolution the better the inter-examiner reliability. The intra-examiner reliability (within a 1-week interval) was considered to be unacceptable for all image resolutions (ICC range: 0.08-0.52). The whole body image of an adult with a minimum size of 768 pixels analyzed on a 96-ppi screen can provide very good inter-examiner reliability for photogrammetric measurements of rearfoot static angles (ICC range: 0.85-0.92), although the intra-examiner reliability within each resolution was not acceptable. Therefore, this method is not a proper tool for follow-up evaluations of patients within a therapeutic protocol.