Data acquisition and readout system for the LUX dark matter experiment
Akerib, D. S.; Bai, X.; Bedikian, S.; ...
2011-11-28
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to detect nuclear recoils from interactions with dark matter particles. Signals from the LUX detector are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. The DAQ is comprised of commercial digitizers with firmware customized for the LUX experiment. Data acquisition systems in rare-event searches must accommodate high rate and large dynamic range during precision calibrations involving radioactive sources, while also delivering low threshold for maximum sensitivity. The LUX DAQ meets these challenges using real-time baseline sup- pression that allows formore » a maximum event acquisition rate in excess of 1.5 kHz with virtually no deadtime. This work describes the LUX DAQ and the novel acquisition techniques employed in the LUX experiment.« less
DEAP-3600 Data Acquisition System
NASA Astrophysics Data System (ADS)
Lindner, Thomas
2015-12-01
DEAP-3600 is a dark matter experiment using liquid argon to detect Weakly Interacting Massive Particles (WIMPs). The DEAP-3600 Data Acquisition (DAQ) has been built using a combination of commercial and custom electronics, organized using the MIDAS framework. The DAQ system needs to suppress a high rate of background events from 39Ar beta decays. This suppression is implemented using a combination of online firmware and software-based event filtering. We will report on progress commissioning the DAQ system, as well as the development of the web-based user interface.
NASA Astrophysics Data System (ADS)
Keleshis, C.; Ioannou, S.; Vrekoussis, M.; Levin, Z.; Lange, M. A.
2014-08-01
Continuous advances in unmanned aerial vehicles (UAV) and the increased complexity of their applications raise the demand for improved data acquisition systems (DAQ). These improvements may comprise low power consumption, low volume and weight, robustness, modularity and capability to interface with various sensors and peripherals while maintaining the high sampling rates and processing speeds. Such a system has been designed and developed and is currently integrated on the Autonomous Flying Platforms for Atmospheric and Earth Surface Observations (APAESO/NEA-YΠOΔOMH/NEKΠ/0308/09) however, it can be easily adapted to any UAV or any other mobile vehicle. The system consists of a single-board computer with a dual-core processor, rugged surface-mount memory and storage device, analog and digital input-output ports and many other peripherals that enhance its connectivity with various sensors, imagers and on-board devices. The system is powered by a high efficiency power supply board. Additional boards such as frame-grabbers, differential global positioning system (DGPS) satellite receivers, general packet radio service (3G-4G-GPRS) modems for communication redundancy have been interfaced to the core system and are used whenever there is a mission need. The onboard DAQ system can be preprogrammed for automatic data acquisition or it can be remotely operated during the flight from the ground control station (GCS) using a graphical user interface (GUI) which has been developed and will also be presented in this paper. The unique design of the GUI and the DAQ system enables the synchronized acquisition of a variety of scientific and UAV flight data in a single core location. The new DAQ system and the GUI have been successfully utilized in several scientific UAV missions. In conclusion, the novel DAQ system provides the UAV and the remote-sensing community with a new tool capable of reliably acquiring, processing, storing and transmitting data from any sensor integrated on an UAV.
Workshop on data acquisition and trigger system simulations for high energy physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1992-12-31
This report discusses the following topics: DAQSIM: A data acquisition system simulation tool; Front end and DCC Simulations for the SDC Straw Tube System; Simulation of Non-Blocklng Data Acquisition Architectures; Simulation Studies of the SDC Data Collection Chip; Correlation Studies of the Data Collection Circuit & The Design of a Queue for this Circuit; Fast Data Compression & Transmission from a Silicon Strip Wafer; Simulation of SCI Protocols in Modsim; Visual Design with vVHDL; Stochastic Simulation of Asynchronous Buffers; SDC Trigger Simulations; Trigger Rates, DAQ & Online Processing at the SSC; Planned Enhancements to MODSEM II & SIMOBJECT -- anmore » Overview -- R.; DAGAR -- A synthesis system; Proposed Silicon Compiler for Physics Applications; Timed -- LOTOS in a PROLOG Environment: an Algebraic language for Simulation; Modeling and Simulation of an Event Builder for High Energy Physics Data Acquisition Systems; A Verilog Simulation for the CDF DAQ; Simulation to Design with Verilog; The DZero Data Acquisition System: Model and Measurements; DZero Trigger Level 1.5 Modeling; Strategies Optimizing Data Load in the DZero Triggers; Simulation of the DZero Level 2 Data Acquisition System; A Fast Method for Calculating DZero Level 1 Jet Trigger Properties and Physics Input to DAQ Studies.« less
Data Acquisition System of Nobeyama MKID Camera
NASA Astrophysics Data System (ADS)
Nagai, M.; Hisamatsu, S.; Zhai, G.; Nitta, T.; Nakai, N.; Kuno, N.; Murayama, Y.; Hattori, S.; Mandal, P.; Sekimoto, Y.; Kiuchi, H.; Noguchi, T.; Matsuo, H.; Dominjon, A.; Sekiguchi, S.; Naruse, M.; Maekawa, J.; Minamidani, T.; Saito, M.
2018-05-01
We are developing a superconducting camera based on microwave kinetic inductance detectors (MKIDs) to observe 100-GHz continuum with the Nobeyama 45-m telescope. A data acquisition (DAQ) system for the camera has been designed to operate the MKIDs with the telescope. This system is required to connect the telescope control system (COSMOS) to the readout system of the MKIDs (MKID DAQ) which employs the frequency-sweeping probe scheme. The DAQ system is also required to record the reference signal of the beam switching for the demodulation by the analysis pipeline in order to suppress the sky fluctuation. The system has to be able to merge and save all data acquired both by the camera and by the telescope, including the cryostat temperature and pressure and the telescope pointing. A collection of software which implements these functions and works as a TCP/IP server on a workstation was developed. The server accepts commands and observation scripts from COSMOS and then issues commands to MKID DAQ to configure and start data acquisition. We made a commissioning of the MKID camera on the Nobeyama 45-m telescope and obtained successful scan signals of the atmosphere and of the Moon.
Developments of a new data acquisition system at ANNRI
NASA Astrophysics Data System (ADS)
Nakao, T.; Terada, K.; Kimura, A.; Nakamura, S.; Iwamoto, O.; Harada, H.; Katabuchi, T.; Igashira, M.; Hori, J.
2017-09-01
A new data acquisition system (DAQ system) has been developed at the Accurate Neutron-Nucleus Reaction Measurement Instrument (ANNRI) facility in the Japan Proton Accelerator Research Complex, Materials and Life Science Experimental Facility (J-PARC/MLF). DAQ systems for both the Ge detector system and the Li-glass detector system were tested by using a gold sample. The applicability of the time-of-flight method was checked. System performance was evaluated on the basis of digital conversion nonlinearity, energy resolution, multi-channel coincidence and dead time.
Messier, Erik
2016-08-01
A Multichannel Systems (MCS) microelectrode array data acquisition (DAQ) unit is used to collect multichannel electrograms (EGM) from a Langendorff perfused rabbit heart system to study sudden cardiac death (SCD). MCS provides software through which data being processed by the DAQ unit can be displayed and saved, but this software's combined utility with MATLAB is not very effective. MCSs software stores recorded EGM data in a MathCad (MCD) format, which is then converted to a text file format. These text files are very large, and it is therefore very time consuming to import the EGM data into MATLAB for real-time analysis. Therefore, customized MATLAB software was developed to control the acquisition of data from the MCS DAQ unit, and provide specific laboratory accommodations for this study of SCD. The developed DAQ unit control software will be able to accurately: provide real time display of EGM signals; record and save EGM signals in MATLAB in a desired format; and produce real time analysis of the EGM signals; all through an intuitive GUI.
Giacomelli, L; Zimbal, A; Reginatto, M; Tittelmeier, K
2011-01-01
A compact NE213 liquid scintillation neutron spectrometer with a new digital data acquisition (DAQ) system is now in operation at the Physikalisch-Technische Bundesanstalt (PTB). With the DAQ system, developed by ENEA Frascati, neutron spectrometry with high count rates in the order of 5×10(5) s(-1) is possible, roughly an order of magnitude higher than with an analog acquisition system. To validate the DAQ system, a new data analysis code was developed and tests were done using measurements with 14-MeV neutrons made at the PTB accelerator. Additional analysis was carried out to optimize the two-gate method used for neutron and gamma (n-γ) discrimination. The best results were obtained with gates of 35 ns and 80 ns. This indicates that the fast and medium decay time components of the NE213 light emission are the ones that are relevant for n-γ discrimination with the digital acquisition system. This differs from what is normally implemented in the analog pulse shape discrimination modules, namely, the fast and long decay emissions of the scintillating light.
Performance Evaluation of a Prototype Underwater Short-Range Acoustic Telemetry Modem
2010-09-01
SR560 Low-Noise Preamplifier – Hewlett Packard (HP) 3314A Function Generator – Phillips PM 3384 Oscilloscope – Dell Latitude D620 notebook...two Stanford Research Systems SR560 low-noise preamplifiers , an IOtech Personal DAQ/3000 Series data acquisition box (DAQ), an HP 3314A function...mono frequency measurements were two B&K 8103 hydrophones, two Stanford Research Systems SR560 low-noise preamplifiers , an IOtech Personal DAQ/3000
Research of Fast DAQ system in KSTAR Thomson scattering diagnostic
NASA Astrophysics Data System (ADS)
Lee, J. H.; Kim, H. J.; Yamada, I.; Funaba, H.; Kim, Y. G.; Kim, D. Y.
2017-12-01
The Thomson scattering diagnostic is one of the most important diagnostic systems in fusion plasma research. It provides reliable electron temperature and density profiles in magnetically confined plasma. A Q-switched Nd:YAG Thomson system was installed several years ago in KSTAR tokamak to measure the electron temperature and density profiles. For the KSTAR Thomson scattering system, a Charge-to-Digital Conversion (QDC) type data acquisition system was used to measure a pulse type Thomson signal. Recently, however, an error was found during the Te, ne calculation, because the QDC system had integrated the pulse Thomson signal that included a signal similar to stray light. To overcome such errors, we introduce a fast data acquisition (F-DAQ) system. To test this, we use CAEN V1742 5 GS/s, a Versa Module Eurocard Bus (VMEbus) type 12-bit switched capacitor digitizer with 32 channels. In this experiment, we compare the calculated Te results of Thomson scattering data measured simultaneously using QDC and F-DAQ. In the F-DAQ system, the shape of the pulse was restored by fitting.
The NIFFTE Data Acquisition System
NASA Astrophysics Data System (ADS)
Qu, Hai; Niffte Collaboration
2011-10-01
The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) will employ a novel, high granularity, pressurized Time Projection Chamber to measure fission cross-sections of the major actinides to high precision over a wide incident neutron energy range. These results will improve nuclear data accuracy and benefit the fuel cycle in the future. The NIFFTE data acquisition system (DAQ) has been designed and implemented on the prototype TPC. Lessons learned from engineering runs have been incorporated into some design changes that are being implemented before the next run cycle. A fully instrumented sextant of EtherDAQ cards (16 sectors, 496 channels) will be used for the next run cycle. The Maximum Integrated Data Acquisition System (MIDAS) has been chosen and customized to configure and run the experiment. It also meets the requirement for remote control and monitoring of the system. The integration of the MIDAS online database with the persistent PostgreSQL database has been implemented for experiment usage. The detailed design and current status of the DAQ system will be presented.
Online polarimetry of the Nuclotron internal deuteron and proton beams
NASA Astrophysics Data System (ADS)
Isupov, A. Yu
2017-12-01
The spin studies at Nuclotron require fast and precise determination of the deuteron and proton beam polarization. For these purposes new powerful VME-based data acquisition (DAQ) system has been designed for the Deuteron Spin Structure setup placed at the Nuclotron Internal Target Station. The DAQ system is built using the netgraph-based data acquisition and processing framework ngdp. The software dealing with VME hardware is a set of netgraph nodes in form of the loadable kernel modules, so works in the operating system kernel context. The specific for current implementation nodes and user context utilities are described. The online events representation by ROOT classes allows us to generalize code for histograms filling and polarization calculations. The DAQ system was successfully used during 53rd and 54th Nuclotron runs, and their suitability for online polarimetry is demonstrated.
Development of the New DAQ System for the SD Array of TA×4 and TALE
NASA Astrophysics Data System (ADS)
Takahashi, Yuichi; Sahara, Ryosuke; Konishi, Shogo; Goto, Takashi; Ogio, Shoichi
The data acquisition (DAQ) system for the surface detector (SD) arrays of TA×4 and TALE will be presented. Each SD records digital signals with 50 MHz FADCs and sends the data to a central communication center (of the "communication tower") via a wireless network system. The technique employed here is based on the currently-running DAQ system of the Telescope Array, and there are some improvements including i) replacement of a wireless LAN module with a custom protocol to another with TCP/IP, and ii) replacement of the "tower electronics" to a generic Linux board PC of Raspberry Pi Type II B. The details and performance of the new DAQ system are described below.
DAQ application of PC oscilloscope for chaos fiber-optic fence system based on LabVIEW
NASA Astrophysics Data System (ADS)
Lu, Manman; Fang, Nian; Wang, Lutang; Huang, Zhaoming; Sun, Xiaofei
2011-12-01
In order to obtain simultaneously high sample rate and large buffer in data acquisition (DAQ) for a chaos fiber-optic fence system, we developed a double-channel high-speed DAQ application of a digital oscilloscope of PicoScope 5203 based on LabVIEW. We accomplished it by creating call library function (CLF) nodes to call the DAQ functions in the two dynamic link libraries (DLLs) of PS5000.dll and PS5000wrap.dll provided by Pico Technology Company. The maximum real-time sample rate of the DAQ application can reach 1GS/s. We can control the resolutions of the application at the sample time and data amplitudes by changing their units in the block diagram, and also control the start and end times of the sampling operations. The experimental results show that the application has enough high sample rate and large buffer to meet the demanding DAQ requirements of the chaos fiber-optic fence system.
VMEbus based computer and real-time UNIX as infrastructure of DAQ
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yasu, Y.; Fujii, H.; Nomachi, M.
1994-12-31
This paper describes what the authors have constructed as the infrastructure of data acquisition system (DAQ). The paper reports recent developments concerned with HP VME board computer with LynxOS (HP742rt/HP-RT) and Alpha/OSF1 with VMEbus adapter. The paper also reports current status of developing a Benchmark Suite for Data Acquisition (DAQBENCH) for measuring not only the performance of VME/CAMAC access but also that of the context switching, the inter-process communications and so on, for various computers including Workstation-based systems and VME board computers.
A FADC-Based Data Acquisition System for the KASCADE-Grande Experiment
NASA Astrophysics Data System (ADS)
Walkowiak, W.; Antoni, T.; Apel, W. D.; Badea, F.; Bekk, K.; Bercuci, A.; Bertaina, M.; Blumer, H.; Bozdog, H.; Brancus, I. M.; Bruggemann, M.; Buchholz, P.; Buttner, C.; Chiavassa, A.; Daumiller, K.; Dipierro, F.; Doll, P.; Engel, R.; Engler, J.; Febler, F.; Ghia, P. L.; Gils, H. J.; Glasstetter, R.; Haungs, A.; Heck, D.; Horandel, J. R.; Kampert, K.-H.; Klages, H. O.; Kolotaev, Y.; Maier, G.; Mathes, H. J.; Mayer, H. J.; Milke, J.; Mitrica, B.; Morello, C.; Muller, M.; Navarra, G.; Obenland, R.; Oehlschlager, J.; Ostapchenko, S.; Over, S.; Petcu, M.; Plewnia, S.; Rebel, H.; Risse, A.; Roth, M.; Schieler, H.; Scholz, J.; Stumpert, M.; Thouw, T.; Toma, G.; Trinchero, G. C.; Ulrich, H.; Valchierotti, S.; Vanburen, J.; Weindl, A.; Wochele, J.; Zabierowski, J.; Zagromski, S.; Zimmermann, D.
2006-02-01
We present the design and first test results of a new FADC-based data acquisition (DAQ) system for the Grande array of the KASCADE-Grande experiment. The original KASCADE experiment at the Forschungszentrum Karlsruhe, Germany, has been extended by 37 detector stations of the former EAS-TOP experiment (Grande array)to provide sensitivity to energies of primary particles from the cosmos of up to $10^{18}$ eV. The new FADC-based DAQ system will improve the quality of the data taken by the Grande array by digitizing the scintillator signals with a 250 MHz sampling rate. events per second. Two Grande stations have been equipped with the FADC-based data acquisition system and first data are shown.
Web-based DAQ systems: connecting the user and electronics front-ends
NASA Astrophysics Data System (ADS)
Lenzi, Thomas
2016-12-01
Web technologies are quickly evolving and are gaining in computational power and flexibility, allowing for a paradigm shift in the field of Data Acquisition (DAQ) systems design. Modern web browsers offer the possibility to create intricate user interfaces and are able to process and render complex data. Furthermore, new web standards such as WebSockets allow for fast real-time communication between the server and the user with minimal overhead. Those improvements make it possible to move the control and monitoring operations from the back-end servers directly to the user and to the front-end electronics, thus reducing the complexity of the data acquisition chain. Moreover, web-based DAQ systems offer greater flexibility, accessibility, and maintainability on the user side than traditional applications which often lack portability and ease of use. As proof of concept, we implemented a simplified DAQ system on a mid-range Spartan6 Field Programmable Gate Array (FPGA) development board coupled to a digital front-end readout chip. The system is connected to the Internet and can be accessed from any web browser. It is composed of custom code to control the front-end readout and of a dual soft-core Microblaze processor to communicate with the client.
Data acquisition system issues for large experiments
NASA Astrophysics Data System (ADS)
Siskind, E. J.
2007-09-01
This talk consists of personal observations on two classes of data acquisition ("DAQ") systems for Silicon trackers in large experiments with which the author has been concerned over the last three or more years. The first half is a classic "lessons learned" recital based on experience with the high-level debug and configuration of the DAQ system for the GLAST LAT detector. The second half is concerned with a discussion of the promises and pitfalls of using modern (and future) generations of "system-on-a-chip" ("SOC") or "platform" field-programmable gate arrays ("FPGAs") in future large DAQ systems. The DAQ system pipeline for the 864k channels of Si tracker in the GLAST LAT consists of five tiers of hardware buffers which ultimately feed into the main memory of the (two-active-node) level-3 trigger processor farm. The data formats and buffer volumes of these tiers are briefly described, as well as the flow control employed between successive tiers. Lessons learned regarding data formats, buffer volumes, and flow control/data discard policy are discussed. The continued development of platform FPGAs containing large amounts of configurable logic fabric, embedded PowerPC hard processor cores, digital signal processing components, large volumes of on-chip buffer memory, and multi-gigabit serial I/O capability permits DAQ system designers to vastly increase the amount of data preprocessing that can be performed in parallel within the DAQ pipeline for detector systems in large experiments. The capabilities of some currently available FPGA families are reviewed, along with the prospects for next-generation families of announced, but not yet available, platform FPGAs. Some experience with an actual implementation is presented, and reconciliation between advertised and achievable specifications is attempted. The prospects for applying these components to space-borne Si tracker detectors are briefly discussed.
NASA Astrophysics Data System (ADS)
Lu, Zenghai; Kasaragoda, Deepa K.; Matcher, Stephen J.
2011-03-01
We compare true 8 and 14 bit-depth imaging of SS-OCT and polarization-sensitive SS-OCT (PS-SS-OCT) at 1.3μm wavelength by using two hardware-synchronized high-speed data acquisition (DAQ) boards. The two DAQ boards read exactly the same imaging data for comparison. The measured system sensitivity at 8-bit depth is comparable to that for 14-bit acquisition when using the more sensitive of the available full analog input voltage ranges of the ADC. Ex-vivo structural and birefringence images of an equine tendon sample indicate no significant differences between images acquired by the two DAQ boards suggesting that 8-bit DAQ boards can be employed to increase imaging speeds and reduce storage in clinical SS-OCT/PS-SS-OCT systems. We also compare the resulting image quality when the image data sampled with the 14-bit DAQ from human finger skin is artificially bit-reduced during post-processing. However, in agreement with the results reported previously, we also observe that in our system that real-world 8-bit image shows more artifacts than the image acquired by numerically truncating to 8-bits from the raw 14-bit image data, especially in low intensity image area. This is due to the higher noise floor and reduced dynamic range of the 8-bit DAQ. One possible disadvantage is a reduced imaging dynamic range which can manifest itself as an increase in image artefacts due to strong Fresnel reflection.
Asymmetric Data Acquisition System for an Endoscopic PET-US Detector
NASA Astrophysics Data System (ADS)
Zorraquino, Carlos; Bugalho, Ricardo; Rolo, Manuel; Silva, Jose C.; Vecklans, Viesturs; Silva, Rui; Ortigão, Catarina; Neves, Jorge A.; Tavernier, Stefaan; Guerra, Pedro; Santos, Andres; Varela, João
2016-02-01
According to current prognosis studies of pancreatic cancer, survival rate nowadays is still as low as 6% mainly due to late detections. Taking into account the location of the disease within the body and making use of the level of miniaturization in radiation detectors that can be achieved at the present time, EndoTOFPET-US collaboration aims at the development of a multimodal imaging technique for endoscopic pancreas exams that combines the benefits of high resolution metabolic information from time-of- flight (TOF) positron emission tomography (PET) with anatomical information from ultrasound (US). A system with such capabilities calls for an application-specific high-performance data acquisition system (DAQ) able to control and readout data from different detectors. The system is composed of two novel detectors: a PET head extension for a commercial US endoscope placed internally close to the region-of-interest (ROI) and a PET plate placed over the patient's abdomen in coincidence with the PET head. These two detectors will send asymmetric data streams that need to be handled by the DAQ system. The approach chosen to cope with these needs goes through the implementation of a DAQ capable of performing multi-level triggering and which is distributed across two different on-detector electronics and the off-detector electronics placed inside the reconstruction workstation. This manuscript provides an overview on the design of this innovative DAQ system and, based on results obtained by means of final prototypes of the two detectors and DAQ, we conclude that a distributed multi-level triggering DAQ system is suitable for endoscopic PET detectors and it shows potential for its application in different scenarios with asymmetric sources of data.
The electronics and data acquisition system for the DarkSide-50 veto detectors
NASA Astrophysics Data System (ADS)
Agnes, P.; Agostino, L.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Covone, G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; De Cecco, S.; De Deo, M.; De Vincenzi, M.; Derbin, A.; Devoto, A.; Di Eusanio, F.; Di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Foster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giganti, C.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K. R.; Hungerford, E. V.; Ianni, Aldo; Ianni, Andrea; James, I.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Lombardi, P.; Luitz, S.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M. E.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Nelson, A.; Odrowski, S.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Riffard, Q.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, S. D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Vishneva, A.; Vogelaar, R. B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.
2016-12-01
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger system have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector.
The LUX experiment - trigger and data acquisition systems
NASA Astrophysics Data System (ADS)
Druszkiewicz, Eryk
2013-04-01
The Large Underground Xenon (LUX) detector is a two-phase xenon time projection chamber designed to detect interactions of dark matter particles with the xenon nuclei. Signals from the detector PMTs are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. During calibrations, both systems must be able to handle high rates and have large dynamic ranges; during dark matter searches, maximum sensitivity requires low thresholds. The trigger system uses eight-channel 64-MHz digitizers (DDC-8) connected to a Trigger Builder (TB). The FPGA cores on the digitizers perform real-time pulse identification (discriminating between S1 and S2-like signals) and event localization. The TB uses hit patterns, hit maps, and maximum response detection to make trigger decisions, which are reached within few microseconds after the occurrence of an event of interest. The DAQ system is comprised of commercial digitizers with customized firmware. Its real-time baseline suppression allows for a maximum event acquisition rate in excess of 1.5 kHz, which results in virtually no deadtime. The performance of the trigger and DAQ systems during the commissioning runs of LUX will be discussed.
Inexpensive Data Acquisition with a Sound Card
NASA Astrophysics Data System (ADS)
Hassan, Umer; Pervaiz, Saad; Anwar, Muhammad Sabieh
2011-12-01
Signal generators, oscilloscopes, and data acquisition (DAQ) systems are standard components of the modern experimental physics laboratory. The sound card, a built-in component in the ubiquitous personal computer, can be utilized for all three of these tasks1,2 and offers an attractive option for labs in developing countries such as ours—Pakistan—where affordability is always of prime concern. In this paper, we describe in a recipe fashion how the sound card is used for DAQ and signal generation.
NASA Astrophysics Data System (ADS)
Czermak, A.; Zalewska, A.; Dulny, B.; Sowicki, B.; Jastrząb, M.; Nowak, L.
2004-07-01
The needs for real time monitoring of the hadrontherapy beam intensity and profile as well as requirements for the fast dosimetry using Monolithic Active Pixel Sensors (MAPS) forced the SUCIMA collaboration to the design of the unique Data Acquisition System (DAQ SUCIMA Imager). The DAQ system has been developed on one of the most advanced XILINX Field Programmable Gate Array chip - VERTEX II. The dedicated multifunctional electronic board for the detector's analogue signals capture, their parallel digital processing and final data compression as well as transmission through the high speed USB 2.0 port has been prototyped and tested.
H4DAQ: a modern and versatile data-acquisition package for calorimeter prototypes test-beams
NASA Astrophysics Data System (ADS)
Marini, A. C.
2018-02-01
The upgrade of the particle detectors for the HL-LHC or for future colliders requires an extensive program of tests to qualify different detector prototypes with dedicated test beams. A common data-acquisition system, H4DAQ, was developed for the H4 test beam line at the North Area of the CERN SPS in 2014 and it has since been adopted in various applications for the CMS experiment and AIDA project. Several calorimeter prototypes and precision timing detectors have used our system from 2014 to 2017. H4DAQ has proven to be a versatile application and has been ported to many other beam test environments. H4DAQ is fast, simple, modular and can be configured to support various kinds of setup. The functionalities of the DAQ core software are split into three configurable finite state machines: data readout, run control, and event builder. The distribution of information and data between the various computers is performed using ZEROMQ (0MQ) sockets. Plugins are available to read different types of hardware, including VME crates with many types of boards, PADE boards, custom front-end boards and beam instrumentation devices. The raw data are saved as ROOT files, using the CERN C++ ROOT libraries. A Graphical User Interface, based on the python gtk libraries, is used to operate the H4DAQ and an integrated data quality monitoring (DQM), written in C++, allows for fast processing of the events for quick feedback to the user. As the 0MQ libraries are also available for the National Instruments LabVIEW program, this environment can easily be integrated within H4DAQ applications.
DAQ for commissioning and calibration of a multichannel analyzer of scintillation counters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tortorici, F.; Jones, M.; Bellini, V.
We report the status of the Data Acquisition (DAQ) system for the Coordinate Detector (CDET) module of the Super Bigbite Spectrometer facility at Hall A of Thomas Jefferson Accelerator Facility. Presently, the DAQ is fully assembled and tested with one CDET module. The commissioning of CDET module, that is the goal of the tests presented here, consists essentially in the measures of the amplitude and time-over-threshold of signals from cosmic rays. Hardware checks, the developing of DAQ control and off-line analysis software are ongoing; the module currently seems to work roughly accordingly to expectations. Data presented in this note aremore » still preliminary.« less
A faster and more reliable data acquisition system for the full performance of the SciCRT
Sasai, Y.; Matsubara, Y.; Itow, Y.; ...
2017-01-03
The SciBar Cosmic Ray Telescope (SciCRT) is a massive scintillator tracker to observe cosmic rays at a very high-altitude environment in Mexico. The fully active tracker is based on the Scintillator Bar (SciBar) detector developed as a near detector for the KEK-to-Kamioka long-baseline neutrino oscillation experiment (K2K) in Japan. Since the data acquisition (DAQ) system was developed for the accelerator experiment, we determined to develop a new robust DAQ system to optimize it to our cosmic-ray experiment needs at the top of Mt. Sierra Negra (4600 m). One of our special requirements is to achieve a 10 times faster readoutmore » rate. We started to develop a new fast readout back-end board (BEB) based on 100 Mbps SiTCP, a hardware network processor developed for DAQ systems for high energy physics experiments. Then we developed the new BEB which has a potential of 20 times faster than the current one in the case of observing neutrons. Lastly, we installed the new DAQ system including the new BEBs to a part of the SciCRT in July 2015. The system has been operating since then. In this article, we describe the development, the basic performance of the new BEB, the status after the installation in the SciCRT, and the future performance.« less
Blanco-Claraco, José Luis; López-Martínez, Javier; Torres-Moreno, José Luis; Giménez-Fernández, Antonio
2015-01-01
Most experimental fields of science and engineering require the use of data acquisition systems (DAQ), devices in charge of sampling and converting electrical signals into digital data and, typically, performing all of the required signal preconditioning. Since commercial DAQ systems are normally focused on specific types of sensors and actuators, systems engineers may need to employ mutually-incompatible hardware from different manufacturers in applications demanding heterogeneous inputs and outputs, such as small-signal analog inputs, differential quadrature rotatory encoders or variable current outputs. A common undesirable side effect of heterogeneous DAQ hardware is the lack of an accurate synchronization between samples captured by each device. To solve such a problem with low-cost hardware, we present a novel modular DAQ architecture comprising a base board and a set of interchangeable modules. Our main design goal is the ability to sample all sources at predictable, fixed sampling frequencies, with a reduced synchronization mismatch (<1 μs) between heterogeneous signal sources. We present experiments in the field of mechanical engineering, illustrating vibration spectrum analyses from piezoelectric accelerometers and, as a novelty in these kinds of experiments, the spectrum of quadrature encoder signals. Part of the design and software will be publicly released online. PMID:26516865
NASA Astrophysics Data System (ADS)
Nakatani, T.; Inamura, Y.; Moriyama, K.; Ito, T.; Muto, S.; Otomo, T.
Neutron scattering can be a powerful probe in the investigation of many phenomena in the materials and life sciences. The Materials and Life Science Experimental Facility (MLF) at the Japan Proton Accelerator Research Complex (J-PARC) is a leading center of experimental neutron science and boasts one of the most intense pulsed neutron sources in the world. The MLF currently has 18 experimental instruments in operation that support a wide variety of users from across a range of research fields. The instruments include optical elements, sample environment apparatus and detector systems that are controlled and monitored electronically throughout an experiment. Signals from these components and those from the neutron source are converted into a digital format by the data acquisition (DAQ) electronics and recorded as time-tagged event data in the DAQ computers using "DAQ-Middleware". Operating in event mode, the DAQ system produces extremely large data files (˜GB) under various measurement conditions. Simultaneously, the measurement meta-data indicating each measurement condition is recorded in XML format by the MLF control software framework "IROHA". These measurement event data and meta-data are collected in the MLF common storage and cataloged by the MLF Experimental Database (MLF EXP-DB) based on a commercial XML database. The system provides a web interface for users to manage and remotely analyze experimental data.
Cheung, Chris C P; Yu, Alfred C H; Salimi, Nazila; Yiu, Billy Y S; Tsang, Ivan K H; Kerby, Benjamin; Azar, Reza Zahiri; Dickie, Kris
2012-02-01
The lack of open access to the pre-beamformed data of an ultrasound scanner has limited the research of novel imaging methods to a few privileged laboratories. To address this need, we have developed a pre-beamformed data acquisition (DAQ) system that can collect data over 128 array elements in parallel from the Ultrasonix series of research-purpose ultrasound scanners. Our DAQ system comprises three system-level blocks: 1) a connector board that interfaces with the array probe and the scanner through a probe connector port; 2) a main board that triggers DAQ and controls data transfer to a computer; and 3) four receiver boards that are each responsible for acquiring 32 channels of digitized raw data and storing them to the on-board memory. This system can acquire pre-beamformed data with 12-bit resolution when using a 40-MHz sampling rate. It houses a 16 GB RAM buffer that is sufficient to store 128 channels of pre-beamformed data for 8000 to 25 000 transmit firings, depending on imaging depth; corresponding to nearly a 2-s period in typical imaging setups. Following the acquisition, the data can be transferred through a USB 2.0 link to a computer for offline processing and analysis. To evaluate the feasibility of using the DAQ system for advanced imaging research, two proof-of-concept investigations have been conducted on beamforming and plane-wave B-flow imaging. Results show that adaptive beamforming algorithms such as the minimum variance approach can generate sharper images of a wire cross-section whose diameter is equal to the imaging wavelength (150 μm in our example). Also, planewave B-flow imaging can provide more consistent visualization of blood speckle movement given the higher temporal resolution of this imaging approach (2500 fps in our example).
Performance of a segmented HPGe detector at KRISS.
Han, Jubong; Lee, K B; Lee, Jong-Man; Lee, S H; Park, Tae Soon; Oh, J S
2018-04-01
A 24 segmented HPGe coaxial detector was set up with a digitized data acquisition system (DAQ). The DAQ was composed of a digitizer (5 × 10 7 sampling/s), a Field-Programmable Gate Array (FPGA), and a real time operating system. The Full Width Half Maximum (FWHM), rise time, signal characteristics, and spectra of a 137 Cs source were evaluated. The data were processed using an in-house developed gamma-ray tracking system. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Shieh-Kung; Loh, Kenneth J.
2015-04-01
The main goal of this study was to develop and validate the performance of a miniature and portable data acquisition (DAQ) system designed for interrogating carbon nanotube (CNT)-based thin films for real-time spatial structural sensing and damage detection. Previous research demonstrated that the electrical properties of CNT-based thin film strain sensors were linearly correlated with applied strains. When coupled with an electrical impedance tomography (EIT) algorithm, the detection and localization of damage was possible. In short, EIT required that the film or "sensing skin" be interrogated along its boundaries. Electrical current was injected across a pair of boundary electrodes, and voltage was simultaneously recorded along the remaining electrode pairs. This was performed multiple times to obtain a large dataset needed for solving the EIT spatial conductivity mapping inverse problem. However, one of the main limitations of this technique was the large amount of time required for data acquisition. In order to facilitate the adoption of this technology and for field implementation purposes, a miniature DAQ that could interrogate these CNT-based sensing skins at high sampling rates was designed and tested. The prototype DAQ featured a Howland current source that could generate stable and controlled direct current. Measurement of boundary electrode voltages and the switching of the input, output, and measurement channels were achieved using multiplexer units. The DAQ prototype was fabricated on a two-layer printed circuit board, and it was designed for integration with a prototype wireless sensing system, which is the next phase of this research.
Data Acquisition Software for Experiments at the MAMI-C Tagged Photon Facility
NASA Astrophysics Data System (ADS)
Oussena, Baya; Annand, John
2013-10-01
Tagged-photon experiments at Mainz use the electron beam of the MAMI (Mainzer MIcrotron) accelerator, in combination with the Glasgow Tagged Photon Spectrometer. The AcquDAQ DAQ system is implemented in the C + + language and makes use of CERN ROOT software libraries and tools. Electronic hardware is characterized in C + + classes, based on a general purpose class TDAQmodule and implementation in an object-oriented framework makes the system very flexible. The DAQ system provides slow control and event-by-event readout of the Photon Tagger, the Crystal Ball 4-pi electromagnetic calorimeter, central MWPC tracker and plastic-scintillator, particle-ID systems and the TAPS forward-angle calorimeter. A variety of front-end controllers running Linux are supported, reading data from VMEbus, FASTBUS and CAMAC systems. More specialist hardware, based on optical communication systems and developed for the COMPASS experiment at CERN, is also supported. AcquDAQ also provides an interface to configure and control the Mainz programmable trigger system, which uses FPGA-based hardware developed at GSI. Currently the DAQ system runs at data rates of up to 3MB/s and, with upgrades to both hardware and software later this year, we anticipate a doubling of that rate. This work was supported in part by the U.S. DOE Grant No. DE-FG02-99ER41110.
A Distributed Data Acquisition System for the Sensor Network of the TAWARA_RTM Project
NASA Astrophysics Data System (ADS)
Fontana, Cristiano Lino; Donati, Massimiliano; Cester, Davide; Fanucci, Luca; Iovene, Alessandro; Swiderski, Lukasz; Moretto, Sandra; Moszynski, Marek; Olejnik, Anna; Ruiu, Alessio; Stevanato, Luca; Batsch, Tadeusz; Tintori, Carlo; Lunardon, Marcello
This paper describes a distributed Data Acquisition System (DAQ) developed for the TAWARA_RTM project (TAp WAter RAdioactivity Real Time Monitor). The aim is detecting the presence of radioactive contaminants in drinking water; in order to prevent deliberate or accidental threats. Employing a set of detectors, it is possible to detect alpha, beta and gamma radiations, from emitters dissolved in water. The Sensor Network (SN) consists of several heterogeneous nodes controlled by a centralized server. The SN cyber-security is guaranteed in order to protect it from external intrusions and malicious acts. The nodes were installed in different locations, along the water treatment processes, in the waterworks plant supplying the aqueduct of Warsaw, Poland. Embedded computers control the simpler nodes, and are directly connected to the SN. Local-PCs (LPCs) control the more complex nodes that consist signal digitizers acquiring data from several detectors. The DAQ in the LPC is split in several processes communicating with sockets in a local sub-network. Each process is dedicated to a very simple task (e.g. data acquisition, data analysis, hydraulics management) in order to have a flexible and fault-tolerant system. The main SN and the local DAQ networks are separated by data routers to ensure the cyber-security.
Fast data transmission in dynamic data acquisition system for plasma diagnostics
NASA Astrophysics Data System (ADS)
Byszuk, Adrian; Poźniak, Krzysztof; Zabołotny, Wojciech M.; Kasprowicz, Grzegorz; Wojeński, Andrzej; Cieszewski, Radosław; Juszczyk, Bartłomiej; Kolasiński, Piotr; Zienkiewicz, Paweł; Chernyshova, Maryna; Czarski, Tomasz
2014-11-01
This paper describes architecture of a new data acquisition system (DAQ) targeted mainly at plasma diagnostic experiments. Modular architecture, in combination with selected hardware components, allows for straightforward reconfiguration of the whole system, both offline and online. Main emphasis will be put into the implementation of data transmission subsystem in said system. One of the biggest advantages of described system is modular architecture with well defined boundaries between main components: analog frontend (AFE), digital backplane and acquisition/control software. Usage of a FPGA chips allows for a high flexibility in design of analog frontends, including ADC <--> FPGA interface. Data transmission between backplane boards and user software was accomplished with the use of industry-standard PCI Express (PCIe) technology. PCIe implementation includes both FPGA firmware and Linux device driver. High flexibility of PCIe connections was accomplished due to use of configurable PCIe switch. Whenever it's possible, described DAQ system tries to make use of standard off-the-shelf (OTF) components, including typical x86 CPU & motherboard (acting as PCIe controller) and cabling.
Orthos, an alarm system for the ALICE DAQ operations
NASA Astrophysics Data System (ADS)
Chapeland, Sylvain; Carena, Franco; Carena, Wisla; Chibante Barroso, Vasco; Costa, Filippo; Denes, Ervin; Divia, Roberto; Fuchs, Ulrich; Grigore, Alexandru; Simonetti, Giuseppe; Soos, Csaba; Telesca, Adriana; Vande Vyvre, Pierre; von Haller, Barthelemy
2012-12-01
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The DAQ (Data Acquisition System) facilities handle the data flow from the detectors electronics up to the mass storage. The DAQ system is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches), and controls hundreds of distributed hardware and software components interacting together. This paper presents Orthos, the alarm system used to detect, log, report, and follow-up abnormal situations on the DAQ machines at the experimental area. The main objective of this package is to integrate alarm detection and notification mechanisms with a full-featured issues tracker, in order to prioritize, assign, and fix system failures optimally. This tool relies on a database repository with a logic engine, SQL interfaces to inject or query metrics, and dynamic web pages for user interaction. We describe the system architecture, the technologies used for the implementation, and the integration with existing monitoring tools.
Continued Data Acquisition Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwellenbach, David
This task focused on improving techniques for integrating data acquisition of secondary particles correlated in time with detected cosmic-ray muons. Scintillation detectors with Pulse Shape Discrimination (PSD) capability show the most promise as a detector technology based on work in FY13. Typically PSD parameters are determined prior to an experiment and the results are based on these parameters. By saving data in list mode, including the fully digitized waveform, any experiment can effectively be replayed to adjust PSD and other parameters for the best data capture. List mode requires time synchronization of two independent data acquisitions (DAQ) systems: the muonmore » tracker and the particle detector system. Techniques to synchronize these systems were studied. Two basic techniques were identified: real time mode and sequential mode. Real time mode is the preferred system but has proven to be a significant challenge since two FPGA systems with different clocking parameters must be synchronized. Sequential processing is expected to work with virtually any DAQ but requires more post processing to extract the data.« less
A direct-to-drive neural data acquisition system.
Kinney, Justin P; Bernstein, Jacob G; Meyer, Andrew J; Barber, Jessica B; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T; Kopell, Nancy J; Boyden, Edward S
2015-01-01
Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future.
A direct-to-drive neural data acquisition system
Kinney, Justin P.; Bernstein, Jacob G.; Meyer, Andrew J.; Barber, Jessica B.; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T.; Kopell, Nancy J.; Boyden, Edward S.
2015-01-01
Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future. PMID:26388740
Analog Input Data Acquisition Software
NASA Technical Reports Server (NTRS)
Arens, Ellen
2009-01-01
DAQ Master Software allows users to easily set up a system to monitor up to five analog input channels and save the data after acquisition. This program was written in LabVIEW 8.0, and requires the LabVIEW runtime engine 8.0 to run the executable.
A High-Temperature Combinatorial Technique for the Thermal Analysis of Materials
2008-07-14
the calorimetric cell. The power dissipated in the thermistor is determined experimentally from the current supplied to the thermistor and the...electronics unit operates as a power supply for the PnSC sensors and as a data acquisition (DAQ) system for the input/output signals from each sensor. Both...the power supply and DAQ operations are galvanically isolated to ensure a maximum signal to noise ratio for the acquired signals. The control
The ATLAS Data Acquisition System: from Run 1 to Run 2
NASA Astrophysics Data System (ADS)
Panduro Vazquez, William; ATLAS Collaboration
2016-04-01
The experience gained during the first period of very successful data taking of the ATLAS experiment (Run 1) has inspired a number of ideas for improvement of the Data Acquisition (DAQ) system that are being put in place during the so-called Long Shutdown 1 of the Large Hadron Collider (LHC), in 2013/14. We have updated the data-flow architecture, rewritten an important fraction of the software and replaced hardware, profiting from state of the art technologies. This paper summarizes the main changes that have been applied to the ATLAS DAQ system and highlights the expected performance and functional improvements that will be available for the LHC Run 2. Particular emphasis will be put on explaining the reasons for our architectural and technical choices, as well as on the simulation and testing approach used to validate this system.
Intelligent FPGA Data Acquisition Framework
NASA Astrophysics Data System (ADS)
Bai, Yunpeng; Gaisbauer, Dominic; Huber, Stefan; Konorov, Igor; Levit, Dmytro; Steffen, Dominik; Paul, Stephan
2017-06-01
In this paper, we present the field programmable gate arrays (FPGA)-based framework intelligent FPGA data acquisition (IFDAQ), which is used for the development of DAQ systems for detectors in high-energy physics. The framework supports Xilinx FPGA and provides a collection of IP cores written in very high speed integrated circuit hardware description language, which use the common interconnect interface. The IP core library offers functionality required for the development of the full DAQ chain. The library consists of Serializer/Deserializer (SERDES)-based time-to-digital conversion channels, an interface to a multichannel 80-MS/s 10-b analog-digital conversion, data transmission, and synchronization protocol between FPGAs, event builder, and slow control. The functionality is distributed among FPGA modules built in the AMC form factor: front end and data concentrator. This modular design also helps to scale and adapt the DAQ system to the needs of the particular experiment. The first application of the IFDAQ framework is the upgrade of the read-out electronics for the drift chambers and the electromagnetic calorimeters (ECALs) of the COMPASS experiment at CERN. The framework will be presented and discussed in the context of this paper.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bouaichaoui, Youcef; Berrahal, Abderezak; Halbaoui, Khaled
This paper describes the design of data acquisition system (DAQ) that is connected to a PC and development of a feedback control system that maintains the coolant temperature of the process at a desired set point using a digital controller system based on the graphical programming language. The paper will provide details about the data acquisition unit, shows the implementation of the controller, and present test results. (authors)
Readout and DAQ for Pixel Detectors
NASA Astrophysics Data System (ADS)
Platkevic, Michal
2010-01-01
Data readout and acquisition control of pixel detectors demand the transfer of significantly a large amounts of bits between the detector and the computer. For this purpose dedicated interfaces are used which are designed with focus on features like speed, small dimensions or flexibility of use such as digital signal processors, field-programmable gate arrays (FPGA) and USB communication ports. This work summarizes the readout and DAQ system built for state-of-the-art pixel detectors of the Medipix family.
Inexpensive Data Acquisition with a Sound Card
ERIC Educational Resources Information Center
Hassan, Umer; Pervaiz, Saad; Anwar, Muhammad Sabieh
2011-01-01
Signal generators, oscilloscopes, and data acquisition (DAQ) systems are standard components of the modern experimental physics laboratory. The sound card, a built-in component in the ubiquitous personal computer, can be utilized for all three of these tasks and offers an attractive option for labs in developing countries such as…
Bartolucci, Veronica
2017-01-01
This work presents a hardware/software data acquisition system developed for monitoring the temperature in real time of the cells in Air-Cooled Polymer Electrolyte Fuel Cells (AC-PEFC). These fuel cells are of great interest because they can carry out, in a single operation, the processes of oxidation and refrigeration. This allows reduction of weight, volume, cost and complexity of the control system in the AC-PEFC. In this type of PEFC (and in general in any PEFC), the reliable monitoring of temperature along the entire surface of the stack is fundamental, since a suitable temperature and a regular distribution thereof, are key for a better performance of the stack and a longer lifetime under the best operating conditions. The developed data acquisition (DAQ) system can perform non-intrusive temperature measurements of each individual cell of an AC-PEFC stack of any power (from watts to kilowatts). The stack power is related to the temperature gradient; i.e., a higher power corresponds to a higher stack surface, and consequently higher temperature difference between the coldest and the hottest point. The developed DAQ system has been implemented with the low-cost open-source platform Arduino, and it is completed with a modular virtual instrument that has been developed using NI LabVIEW. Temperature vs time evolution of all the cells of an AC-PEFC both together and individually can be registered and supervised. The paper explains comprehensively the developed DAQ system together with experimental results that demonstrate the suitability of the system. PMID:28698497
Segura, Francisca; Bartolucci, Veronica; Andújar, José Manuel
2017-07-09
This work presents a hardware/software data acquisition system developed for monitoring the temperature in real time of the cells in Air-Cooled Polymer Electrolyte Fuel Cells (AC-PEFC). These fuel cells are of great interest because they can carry out, in a single operation, the processes of oxidation and refrigeration. This allows reduction of weight, volume, cost and complexity of the control system in the AC-PEFC. In this type of PEFC (and in general in any PEFC), the reliable monitoring of temperature along the entire surface of the stack is fundamental, since a suitable temperature and a regular distribution thereof, are key for a better performance of the stack and a longer lifetime under the best operating conditions. The developed data acquisition (DAQ) system can perform non-intrusive temperature measurements of each individual cell of an AC-PEFC stack of any power (from watts to kilowatts). The stack power is related to the temperature gradient; i.e., a higher power corresponds to a higher stack surface, and consequently higher temperature difference between the coldest and the hottest point. The developed DAQ system has been implemented with the low-cost open-source platform Arduino, and it is completed with a modular virtual instrument that has been developed using NI LabVIEW. Temperature vs time evolution of all the cells of an AC-PEFC both together and individually can be registered and supervised. The paper explains comprehensively the developed DAQ system together with experimental results that demonstrate the suitability of the system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McKisson, John
The source code for the Java Data Acquisition suite provides interfaces to the JLab built USB FPGA ADC across a LAN network. Each jDaq node provides ListMode data from JLab built detector systems and readouts.
A new data acquisition system for the CMS Phase 1 pixel detector
NASA Astrophysics Data System (ADS)
Kornmayer, A.
2016-12-01
A new pixel detector will be installed in the CMS experiment during the extended technical stop of the LHC at the beginning of 2017. The new pixel detector, built from four layers in the barrel region and three layers on each end of the forward region, is equipped with upgraded front-end readout electronics, specifically designed to handle the high particle hit rates created in the LHC environment. The DAQ back-end was entirely redesigned to handle the increased number of readout channels, the higher data rates per channel and the new digital data format. Based entirely on the microTCA standard, new front-end controller (FEC) and front-end driver (FED) cards have been developed, prototyped and produced with custom optical link mezzanines mounted on the FC7 AMC and custom firmware. At the same time as the new detector is being assembled, the DAQ system is set up and its integration into the CMS central DAQ system tested by running the pilot blade detector already installed in CMS. This work describes the DAQ system, integration tests and gives an outline for the activities up to commissioning the final system at CMS in 2017.
A New Event Builder for CMS Run II
NASA Astrophysics Data System (ADS)
Albertsson, K.; Andre, J.-M.; Andronidis, A.; Behrens, U.; Branson, J.; Chaze, O.; Cittolin, S.; Darlea, G.-L.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Gigi, D.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; Nunez-Barranco-Fernandez, C.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Roberts, P.; Sakulin, H.; Schwick, C.; Stieger, B.; Sumorok, K.; Veverka, J.; Zaza, S.; Zejdl, P.
2015-12-01
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100GB/s to the high-level trigger (HLT) farm. The DAQ system has been redesigned during the LHC shutdown in 2013/14. The new DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbps Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbps Infiniband FDR CLOS network has been chosen for the event builder. This paper discusses the software design, protocols, and optimizations for exploiting the hardware capabilities. We present performance measurements from small-scale prototypes and from the full-scale production system.
A new event builder for CMS Run II
Albertsson, K.; Andre, J-M; Andronidis, A.; ...
2015-12-23
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider (LHC) assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100 GB/s to the high-level trigger (HLT) farm. The DAQ system has been redesigned during the LHC shutdown in 2013/14. The new DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbps Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbps Innibandmore » FDR CLOS network has been chosen for the event builder. This paper discusses the software design, protocols, and optimizations for exploiting the hardware capabilities. In conclusion, ee present performance measurements from small-scale prototypes and from the full-scale production system.« less
NASA Astrophysics Data System (ADS)
Martinez, J. D.; Benlloch, J. M.; Cerda, J.; Lerche, Ch. W.; Pavon, N.; Sebastia, A.
2004-06-01
This paper is framed into the Positron Emission Mammography (PEM) project, whose aim is to develop an innovative gamma ray sensor for early breast cancer diagnosis. Currently, breast cancer is detected using low-energy X-ray screening. However, functional imaging techniques such as PET/FDG could be employed to detect breast cancer and track disease changes with greater sensitivity. Furthermore, a small and less expensive PET camera can be utilized minimizing main problems of whole body PET. To accomplish these objectives, we are developing a new gamma ray sensor based on a newly released photodetector. However, a dedicated PEM detector requires an adequate data acquisition (DAQ) and processing system. The characterization of gamma events needs a free-running analog-to-digital converter (ADC) with sampling rates of more than 50 Ms/s and must achieve event count rates up to 10 MHz. Moreover, comprehensive data processing must be carried out to obtain event parameters necessary for performing the image reconstruction. A new generation digital signal processor (DSP) has been used to comply with these requirements. This device enables us to manage the DAQ system at up to 80 Ms/s and to execute intensive calculi over the detector signals. This paper describes our designed DAQ and processing architecture whose main features are: very high-speed data conversion, multichannel synchronized acquisition with zero dead time, a digital triggering scheme, and high throughput of data with an extensive optimization of the signal processing algorithms.
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition.
Sun, Limin; Han, Menglai; Pratt, Kevin; Paulson, Douglas; Dinh, Christoph; Esch, Lorenz; Okada, Yoshio; Hämäläinen, Matti
2017-05-01
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
Versatile synchronized real-time MEG hardware controller for large-scale fast data acquisition
NASA Astrophysics Data System (ADS)
Sun, Limin; Han, Menglai; Pratt, Kevin; Paulson, Douglas; Dinh, Christoph; Esch, Lorenz; Okada, Yoshio; Hämäläinen, Matti
2017-05-01
Versatile controllers for accurate, fast, and real-time synchronized acquisition of large-scale data are useful in many areas of science, engineering, and technology. Here, we describe the development of a controller software based on a technique called queued state machine for controlling the data acquisition (DAQ) hardware, continuously acquiring a large amount of data synchronized across a large number of channels (>400) at a fast rate (up to 20 kHz/channel) in real time, and interfacing with applications for real-time data analysis and display of electrophysiological data. This DAQ controller was developed specifically for a 384-channel pediatric whole-head magnetoencephalography (MEG) system, but its architecture is useful for wide applications. This controller running in a LabVIEW environment interfaces with microprocessors in the MEG sensor electronics to control their real-time operation. It also interfaces with a real-time MEG analysis software via transmission control protocol/internet protocol, to control the synchronous acquisition and transfer of the data in real time from >400 channels to acquisition and analysis workstations. The successful implementation of this controller for an MEG system with a large number of channels demonstrates the feasibility of employing the present architecture in several other applications.
Performance of the NOνA Data Acquisition and Trigger Systems for the full 14 kT Far Detector
NASA Astrophysics Data System (ADS)
Norman, A.; Davies, G. S.; Ding, P. F.; Dukes, E. C.; Duyan, H.; Frank, M. J.; R. C. Group; Habig, A.; Henderson, W.; Niner, E.; Mina, R.; Moren, A.; Mualem, L.; Oksuzian, Y.; Rebel, B.; Shanahan, P.; Sheshukov, A.; Tamsett, M.; Tomsen, K.; Vinton, L.; Wang, Z.; Zamorano, B.; Zirnstien, J.
2015-12-01
The NOvA experiment uses a continuous, free-running, dead-timeless data acquisition system to collect data from the 14 kT far detector. The DAQ system readouts the more than 344,000 detector channels and assembles the information into an raw unfiltered high bandwidth data stream. The NOvA trigger systems operate in parallel to the readout and asynchronously to the primary DAQ readout/event building chain. The data driven triggering systems for NOvA are unique in that they examine long contiguous time windows of the high resolution readout data and enable the detector to be sensitive to a wide range of physics interactions from those with fast, nanosecond scale signals up to processes with long delayed coincidences between hits which occur at the tens of milliseconds time scale. The trigger system is able to achieve a true 100% live time for the detector, making it sensitive to both beam spill related and off-spill physics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agnes, P.; Agostino, L.; Albuquerque, I. F. M.
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles. It utilizes a liquid argon time projection chamber for the inner main detector, surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors. The system is made of a custom built front end electronics and commercial National Instruments high speed digitizers. The front end electronics, the DAQ, and the trigger systemmore » have been used to acquire data in the form of zero-suppressed waveform samples from the 110 PMTs of the LSV and the 80 PMTs of the WCV. The veto DAQ system has proven its performance and reliability. This electronics and DAQ system can be scaled and used as it is for the veto of the next generation DarkSide-20k detector. Abstract (arXiv)« less
NASA Astrophysics Data System (ADS)
Krawczyk, Rafał D.; Czarski, Tomasz; Kolasiński, Piotr; Linczuk, Paweł; Poźniak, Krzysztof T.; Chernyshova, Maryna; Kasprowicz, Grzegorz; Wojeński, Andrzej; Zabolotny, Wojciech; Zienkiewicz, Paweł
2016-09-01
This article is an overview of what has been implemented in the process of development and testing the GEM detector based acquisition system in terms of post-processing algorithms. Information is given on mex functions for extended statistics collection, unified hex topology and optimized S-DAQ algorithm for splitting overlapped signals. Additional discussion on bottlenecks and major factors concerning optimization is presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, J.M.; et al.
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of to the high-level trigger farm. The DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbit/s Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbit/s Infiniband FDR Clos network has been chosen for the event builder. This paper presents the implementation and performancemore » of the event-building system.« less
NASA Astrophysics Data System (ADS)
Conforti, Vito; Trifoglio, Massimo; Bulgarelli, Andrea; Gianotti, Fulvio; Fioretti, Valentina; Tacchini, Alessandro; Zoli, Andrea; Malaguti, Giuseppe; Capalbi, Milvia; Catalano, Osvaldo
2014-07-01
ASTRI (Astrofisica con Specchi a Tecnologia Replicante Italiana) is a Flagship Project financed by the Italian Ministry of Education, University and Research, and led by INAF, the Italian National Institute of Astrophysics. Within this framework, INAF is currently developing an end-to-end prototype of a Small Size dual-mirror Telescope. In a second phase the ASTRI project foresees the installation of the first elements of the array at CTA southern site, a mini-array of 7 telescopes. The ASTRI Camera DAQ Software is aimed at the Camera data acquisition, storage and display during Camera development as well as during commissioning and operations on the ASTRI SST-2M telescope prototype that will operate at the INAF observing station located at Serra La Nave on the Mount Etna (Sicily). The Camera DAQ configuration and operations will be sequenced either through local operator commands or through remote commands received from the Instrument Controller System that commands and controls the Camera. The Camera DAQ software will acquire data packets through a direct one-way socket connection with the Camera Back End Electronics. In near real time, the data will be stored in both raw and FITS format. The DAQ Quick Look component will allow the operator to display in near real time the Camera data packets. We are developing the DAQ software adopting the iterative and incremental model in order to maximize the software reuse and to implement a system which is easily adaptable to changes. This contribution presents the Camera DAQ Software architecture with particular emphasis on its potential reuse for the ASTRI/CTA mini-array.
Data Acquisition Backbone Core DABC release v1.0
NASA Astrophysics Data System (ADS)
Adamczewski-Musch, J.; Essel, H. G.; Kurz, N.; Linev, S.
2010-04-01
The Data Acquisition Backbone Core (DABC) is a general purpose software framework designed for the implementation of a wide-range of data acquisition systems - from various small detector test beds to high performance systems. DABC consists of a compact data-flow kernel and a number of plug-ins for various functional components like data inputs, device drivers, user functional modules and applications. DABC provides configurable components for implementing event building over fast networks like InfiniBand or Gigabit Ethernet. A generic Java GUI provides the dynamic control and visualization of control parameters and commands, provided by DIM servers. A first set of application plug-ins has been implemented to use DABC as event builder for the front-end components of the GSI standard DAQ system MBS (Multi Branch System). Another application covers the connection to DAQ readout chains from detector front-end boards (N-XYTER) linked to read-out controller boards (ROC) over UDP into DABC for event building, archiving and data serving. This was applied for data taking in the September 2008 test beamtime for the CBM experiment at GSI. DABC version 1.0 is released and available from the website.
PCI/iRMX-Based Front-End Data Acquisition for the HT-7U Experiment
NASA Astrophysics Data System (ADS)
Shu, Yantai; Luo, Jiarong; Yan, Jianbing; Zhao, Feng; Zhang, Liang
2004-06-01
A PCI/iRMX-based front-end system is being designed to serve as data acquisition (DAQ) subsystem for the HT-7U superconducting tokamak. The diagnostic instruments are connected to four analog-to-digital converter (ADC) boards that are directly plugged into the peripheral component interconnect (PCI) bus of a personal computer (PC) running the iRMX real-time operating system. Each ADC board has eight channels. The sampling rate of each channel can be up to 125 K samples per second. The acquired data are directly transferred from the ADC board into the memory of the PC, and then transferred to servers through the network. As a testbed, one PCI/iRMX subsystem has been built and has acquired data from the existing HT-7 tokamak. The DAQ can easily support a wide range of pulse lengths, even matching extremely long pulse and steady-state operation. This paper describes the system design and performance evaluation in detail.
New Software Architecture Options for the TCL Data Acquisition System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Valenton, Emmanuel
2014-09-01
The Turbulent Combustion Laboratory (TCL) conducts research on combustion in turbulent flow environments. To conduct this research, the TCL utilizes several pulse lasers, a traversable wind tunnel, flow controllers, scientific grade CCD cameras, and numerous other components. Responsible for managing these different data-acquiring instruments and data processing components is the Data Acquisition (DAQ) software. However, the current system is constrained to running through VXI hardware—an instrument-computer interface—that is several years old, requiring the use of an outdated version of the visual programming language, LabVIEW. A new Acquisition System is being programmed which will borrow heavily from either a programming modelmore » known as the Current Value Table (CVT) System or another model known as the Server-Client System. The CVT System model is in essence, a giant spread sheet from which data or commands may be retrieved or written to, and the Server-Client System is based on network connections between a server and a client, very much like the Server-Client model of the Internet. Currently, the bare elements of a CVT DAQ Software have been implemented, consisting of client programs in addition to a server program that the CVT will run on. This system is being rigorously tested to evaluate the merits of pursuing the CVT System model and to uncover any potential flaws which may result in further implementation. If the CVT System is chosen, which is likely, then future work will consist of build up the system until enough client programs have been created to run the individual components of the lab. The advantages of such a System will be flexibility, portability, and polymorphism. Additionally, the new DAQ software will allow the Lab to replace the VXI with a newer instrument interface—the PXI—and take advantage of the capabilities of current and future versions of LabVIEW.« less
NASA Astrophysics Data System (ADS)
Mandal, Swagata; Saini, Jogender; Zabołotny, Wojciech M.; Sau, Suman; Chakrabarti, Amlan; Chattopadhyay, Subhasis
2017-03-01
Due to the dramatic increase of data volume in modern high energy physics (HEP) experiments, a robust high-speed data acquisition (DAQ) system is very much needed to gather the data generated during different nuclear interactions. As the DAQ works under harsh radiation environment, there is a fair chance of data corruption due to various energetic particles like alpha, beta, or neutron. Hence, a major challenge in the development of DAQ in the HEP experiment is to establish an error resilient communication system between front-end sensors or detectors and back-end data processing computing nodes. Here, we have implemented the DAQ using field-programmable gate array (FPGA) due to some of its inherent advantages over the application-specific integrated circuit. A novel orthogonal concatenated code and cyclic redundancy check (CRC) have been used to mitigate the effects of data corruption in the user data. Scrubbing with a 32-b CRC has been used against error in the configuration memory of FPGA. Data from front-end sensors will reach to the back-end processing nodes through multiple stages that may add an uncertain amount of delay to the different data packets. We have also proposed a novel memory management algorithm that helps to process the data at the back-end computing nodes removing the added path delays. To the best of our knowledge, the proposed FPGA-based DAQ utilizing optical link with channel coding and efficient memory management modules can be considered as first of its kind. Performance estimation of the implemented DAQ system is done based on resource utilization, bit error rate, efficiency, and robustness to radiation.
On the Sensitivity of the HAWC Observatory to Gamma-Ray Bursts
NASA Technical Reports Server (NTRS)
Hays, E.; McEnery, Julie E.
2011-01-01
We present the sensitivity of HAWC to Gamma Ray Bursts (GRBs). HAWC is a very high-energy gamma-ray observatory currently under construction in Mexico at an altitude of 4100 m. It will observe atmospheric air showers via the water Cherenkov method. HAWC will consist of 300 large water tanks instrumented with 4 photomultipliers each. HAWC has two data acquisition (DAQ) systems. The main DAQ system reads out coincident signals in the tanks and reconstructs the direction and energy of individual atmospheric showers. The scaler DAQ counts the hits in each photomultiplier tube (PMT) in the detector and searches for a statistical excess over the noise of all PMTs. We show that HAWC has a realistic opportunity to observe the high-energy power law components of GRBs that extend at least up to 30 GeV, as it has been observed by Fermi LAT. The two DAQ systems have an energy threshold that is low enough to observe events similar to GRB 090510 and GRB 090902b with the characteristics observed by Fermi LAT. HAWC will provide information about the high-energy spectra of GRBs which in turn will lead to understanding about e-pair attenuation in GRB jets, extragalactic background light absorption, as well as establishing the highest energy to which GRBs accelerate particles.
Upgraded photon calorimeter with integrating readout for Hall A Compton Polarimeter at Jefferson Lab
Friend, M.; Parno, D.; Benmokhtar, F.; ...
2012-06-01
The photon arm of the Compton polarimeter in Hall A of Jefferson Lab has been upgraded to allow for electron beam polarization measurements with better than 1% accuracy. The data acquisition system (DAQ) now includes an integrating mode, which eliminates several systematic uncertainties inherent in the original counting-DAQ setup. The photon calorimeter has been replaced with a Ce-doped Gd 2SiO 5 crystal, which has a bright output and fast response, and works well for measurements using the new integrating method at electron beam energies from 1 to 6 GeV.
Real-Time Data Streaming and Storing Structure for the LHD's Fusion Plasma Experiments
NASA Astrophysics Data System (ADS)
Nakanishi, Hideya; Ohsuna, Masaki; Kojima, Mamoru; Imazu, Setsuo; Nonomura, Miki; Emoto, Masahiko; Yoshida, Masanobu; Iwata, Chie; Ida, Katsumi
2016-02-01
The LHD data acquisition and archiving system, i.e., LABCOM system, has been fully equipped with high-speed real-time acquisition, streaming, and storage capabilities. To deal with more than 100 MB/s continuously generated data at each data acquisition (DAQ) node, DAQ tasks have been implemented as multitasking and multithreaded ones in which the shared memory plays the most important role for inter-process fast and massive data handling. By introducing a 10-second time chunk named “subshot,” endless data streams can be stored into a consecutive series of fixed length data blocks so that they will soon become readable by other processes even while the write process is continuing. Real-time device and environmental monitoring are also implemented in the same way with further sparse resampling. The central data storage has been separated into two layers to be capable of receiving multiple 100 MB/s inflows in parallel. For the frontend layer, high-speed SSD arrays are used as the GlusterFS distributed filesystem which can provide max. 2 GB/s throughput. Those design optimizations would be informative for implementing the next-generation data archiving system in big physics, such as ITER.
Performance of the CMS Event Builder
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Behrens, U.; Branson, J.; Brummer, P.; Chaze, O.; Cittolin, S.; Contescu, C.; Craigs, B. G.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Doualot, N.; Erhan, S.; Fulcher, J. F.; Gigi, D.; Gładki, M.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Janulis, M.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; O'Dell, V.; Orsini, L.; Paus, C.; Petrova, P.; Pieri, M.; Racz, A.; Reis, T.; Sakulin, H.; Schwick, C.; Simelevicius, D.; Zejdl, P.
2017-10-01
The data acquisition system (DAQ) of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of {\\mathscr{O}}(100 {{GB}}/{{s}}) to the high-level trigger farm. The DAQ architecture is based on state-of-the-art network technologies for the event building. For the data concentration, 10/40 Gbit/s Ethernet technologies are used together with a reduced TCP/IP protocol implemented in FPGA for a reliable transport between custom electronics and commercial computing hardware. A 56 Gbit/s Infiniband FDR Clos network has been chosen for the event builder. This paper presents the implementation and performance of the event-building system.
The DZERO Level 3 Data Acquisition System
NASA Astrophysics Data System (ADS)
Angstadt, R.; Brooijmans, G.; Chapin, D.; Clements, M.; Cutts, D.; Haas, A.; Hauser, R.; Johnson, M.; Kulyavtsev, A.; Mattingly, S. E. K.; Mulders, M.; Padley, P.; Petravick, D.; Rechenmacher, R.; Snyder, S.; Watts, G.
2004-06-01
The DZERO experiment began RunII datataking operation at Fermilab in spring 2001. The physics program of the experiment requires the Level 3 data acquisition (DAQ) system system to handle average event sizes of 250 kilobytes at a rate of 1 kHz. The system routes and transfers event fragments of approximately 1-20 kilobytes from 63 VME crate sources to any of approximately 100 processing nodes. It is built upon a Cisco 6509 Ethernet switch, standard PCs, and commodity VME single board computers (SBCs). The system has been in full operation since spring 2002.
Real Time Data Acquisition and Online Signal Processing for Magnetoencephalography
NASA Astrophysics Data System (ADS)
Rongen, H.; Hadamschek, V.; Schiek, M.
2006-06-01
To establish improved therapies for patients suffering from severe neurological and psychiatric diseases, a demand controlled and desynchronizing brain-pacemaker has been developed with techniques from statistical physics and nonlinear dynamics. To optimize the novel therapeutic approach, brain activity is investigated with a Magnetoencephalography (MEG) system prior to surgery. For this, a real time data acquisition system for a 148 channel MEG and online signal processing for artifact rejection, filtering, cross trial phase resetting analysis and three-dimensional (3-D) reconstruction of the cerebral current sources was developed. The developed PCI bus hardware is based on a FPGA and DSP design, using the benefits from both architectures. The reconstruction and visualization of the 3-D volume data is done by the PC which hosts the real time DAQ and pre-processing board. The framework of the MEG-online system is introduced and the architecture of the real time DAQ board and online reconstruction is described. In addition we show first results with the MEG-Online system for the investigation of dynamic brain activities in relation to external visual stimulation, based on test data sets.
A Measurement of Neutral B Mixing using Di-Lepton Events with the BaBar Detector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gunawardane, Naveen
This thesis reports on a measurement of the neutral B meson mixing parameter, Δm d, at the BABAR experiment and the work carried out on the electromagnetic calorimeter (EMC) data acquisition (DAQ) system and simulation software.
The Belle II Pixel Detector Data Acquisition and Background Suppression System
NASA Astrophysics Data System (ADS)
Lautenbach, K.; Deschamps, B.; Dingfelder, J.; Getzkow, D.; Geßler, T.; Konorov, I.; Kühn, W.; Lange, S.; Levit, D.; Liu, Z.-A.; Marinas, C.; Münchow, D.; Rabusov, A.; Reiter, S.; Spruck, B.; Wessel, C.; Zhao, J.
2017-06-01
The Belle II experiment at the future SuperKEKB collider in Tsukuba, Japan, features a design luminosity of 8 · 1035 cm-2s-1, which is a factor of 40 larger than that of its predecessor Belle. The pixel detector (PXD) with about 8 million pixels is based on the DEPFET technology and will improve the vertex resolution in beam direction by a factor of 2. With an estimated trigger rate of 30 kHz, the PXD is expected to generate a data rate of 20 GBytes/s, which is about 10 times larger than the amount of data generated by all other Belle II subdetectors. Due to the large beam-related background, the PXD requires a data acquisition system with high-bandwidth data links and realtime background reduction by a factor of 30. To achieve this, the Belle II pixel DAQ uses an FPGA-based computing platform with high speed serial links implemented in the ATCA (Advanced Telecommunications Computing Architecture) standard. The architecture and performance of the data acquisition system and data reduction of the PXD will be presented. In April 2016 and February 2017 a prototype PXD-DAQ system operated in a test beam campaign delivered data with the whole readout chain under realistic high rate conditions. Final results from the beam test will be presented.
Three Generations of FPGA DAQ Development for the ATLAS Pixel Detector
NASA Astrophysics Data System (ADS)
Mayer, Joseph A., II
The Large Hadron Collider (LHC) at the European Center for Nuclear Research (CERN) tracks a schedule of long physics runs, followed by periods of inactivity known as Long Shutdowns (LS). During these LS phases both the LHC, and the experiments around its ring, undergo maintenance and upgrades. For the LHC these upgrades improve their ability to create data for physicists; the more data the LHC can create the more opportunities there are for rare events to appear that physicists will be interested in. The experiments upgrade so they can record the data and ensure the event won't be missed. Currently the LHC is in Run 2 having completed the first LS of three. This thesis focuses on the development of Field-Programmable Gate Array (FPGA)-based readout systems that span across three major tasks of the ATLAS Pixel data acquisition (DAQ) system. The evolution of Pixel DAQ's Readout Driver (ROD) card is presented. Starting from improvements made to the new Insertable B-Layer (IBL) ROD design, which was part of the LS1 upgrade; to upgrading the old RODs from Run 1 to help them run more efficiently in Run 2. It also includes the research and development of FPGA based DAQs and integrated circuit emulators for the ITk upgrade which will occur during LS3 in 2025.
Digital Electronics for Nuclear Physics Experiments
NASA Astrophysics Data System (ADS)
Skulski, Wojtek; Hunter, David; Druszkiewicz, Eryk; Khaitan, Dev Ashish; Yin, Jun; Wolfs, Frank; SkuTek Instrumentation Team; Department of Physics; Astronomy, University of Rochester Team
2015-10-01
Future detectors in nuclear physics will use signal sampling as one of primary techniques of data acquisition. Using the digitized waveforms, the electronics can select events based on pulse shape, total energy, multiplicity, and the hit pattern. The DAQ for the LZ Dark Matter detector, now under development in Rochester, is a good example of the power of digital signal processing. This system, designed around 32-channel, FPGA-based, digital signal processors collects data from more than one thousand channels. The solutions developed for this DAQ can be applied to nuclear physics experiments. Supported by the Department of Energy Office of Science under Grant DE-SC0009543.
Software engineering techniques and CASE tools in RD13
NASA Astrophysics Data System (ADS)
Buono, S.; Gaponenko, I.; Jones, R.; Khodabandeh, A.; Mapelli, L.; Mornacchi, G.; Prigent, D.; Sanchez-Corral, E.; Skiadelli, M.; Toppers, A.; Duval, P. Y.; Ferrato, D.; Le Van Suu, A.; Qian, Z.; Rondot, C.; Ambrosini, G.; Fumagalli, G.; Polesello, G.; Aguer, M.; Huet, M.
1994-12-01
The RD13 project was approved in April 1991 for the development of a scalable data-taking system suitable for hosting various LHC studies. One of its goals is the exploitation of software engineering techniques, in order to indicate their overall suitability for data acquisition (DAQ), software design and implementation. This paper describes how such techniques have been applied to the development of components of the RD13 DAQ used in test-beam runs at CERN. We describe our experience with the Artifex CASE tool and its associated methodology. The issues raised when code generated by a CASE tool has to be integrated into an existing environment are also discussed.
Inexpensive DAQ based physics labs
NASA Astrophysics Data System (ADS)
Lewis, Benjamin; Clark, Shane
2015-11-01
Quality Data Acquisition (DAQ) based physics labs can be designed using microcontrollers and very low cost sensors with minimal lab equipment. A prototype device with several sensors and documentation for a number of DAQ-based labs is showcased. The device connects to a computer through Bluetooth and uses a simple interface to control the DAQ and display real time graphs, storing the data in .txt and .xls formats. A full device including a larger number of sensors combined with software interface and detailed documentation would provide a high quality physics lab education for minimal cost, for instance in high schools lacking lab equipment or students taking online classes. An entire semester’s lab course could be conducted using a single device with a manufacturing cost of under $20.
Upgrade of the TOTEM DAQ using the Scalable Readout System (SRS)
NASA Astrophysics Data System (ADS)
Quinto, M.; Cafagna, F.; Fiergolski, A.; Radicioni, E.
2013-11-01
The main goals of the TOTEM Experiment at the LHC are the measurements of the elastic and total p-p cross sections and the studies of the diffractive dissociation processes. At LHC, collisions are produced at a rate of 40 MHz, imposing strong requirements for the Data Acquisition Systems (DAQ) in terms of trigger rate and data throughput. The TOTEM DAQ adopts a modular approach that, in standalone mode, is based on VME bus system. The VME based Front End Driver (FED) modules, host mezzanines that receive data through optical fibres directly from the detectors. After data checks and formatting are applied in the mezzanine, data is retransmitted to the VME interface and to another mezzanine card plugged in the FED module. The VME bus maximum bandwidth limits the maximum first level trigger (L1A) to 1 kHz rate. In order to get rid of the VME bottleneck and improve scalability and the overall capabilities of the DAQ, a new system was designed and constructed based on the Scalable Readout System (SRS), developed in the framework of the RD51 Collaboration. The project aims to increase the efficiency of the actual readout system providing higher bandwidth, and increasing data filtering, implementing a second-level trigger event selection based on hardware pattern recognition algorithms. This goal is to be achieved preserving the maximum back compatibility with the LHC Timing, Trigger and Control (TTC) system as well as with the CMS DAQ. The obtained results and the perspectives of the project are reported. In particular, we describe the system architecture and the new Opto-FEC adapter card developed to connect the SRS with the FED mezzanine modules. A first test bench was built and validated during the last TOTEM data taking period (February 2013). Readout of a set of 3 TOTEM Roman Pot silicon detectors was carried out to verify performance in the real LHC environment. In addition, the test allowed a check of data consistency and quality.
Si, Jiahe; Colgate, Stirling A; Li, Hui; Martinic, Joe; Westpfahl, David
2013-10-01
New Mexico Institute of Mining and Technology liquid sodium αω-dynamo experiment models the magnetic field generation in the universe as discussed in detail by Colgate, Li, and Pariev [Phys. Plasmas 8, 2425 (2001)]. To obtain a quasi-laminar flow with magnetic Reynolds number R(m) ~ 120, the dynamo experiment consists of two co-axial cylinders of 30.5 cm and 61 cm in diameter spinning up to 70 Hz and 17.5 Hz, respectively. During the experiment, the temperature of the cylinders must be maintained to 110 °C to ensure that the sodium remains fluid. This presents a challenge to implement a data acquisition (DAQ) system in such high temperature, high-speed rotating frame, in which the sensors (including 18 Hall sensors, 5 pressure sensors, and 5 temperature sensors, etc.) are under the centrifugal acceleration up to 376g. In addition, the data must be transmitted and stored in a computer 100 ft away for safety. The analog signals are digitized, converted to serial signals by an analog-to-digital converter and a field-programmable gate array. Power is provided through brush/ring sets. The serial signals are sent through ring/shoe sets capacitively, then reshaped with cross-talk noises removed. A microcontroller-based interface circuit is used to decode the serial signals and communicate with the data acquisition computer. The DAQ accommodates pressure up to 1000 psi, temperature up to more than 130 °C, and magnetic field up to 1000 G. First physics results have been analyzed and published. The next stage of the αω-dynamo experiment includes the DAQ system upgrade.
Commissioning and initial experience with the ALICE on-line
NASA Astrophysics Data System (ADS)
Altini, V.; Anticic, T.; Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F.; Dénes, E.; Divià, R.; Fuchs, U.; Kiss, T.; Makhlyueva, I.; Roukoutakis, F.; Schossmaier, K.; Soós, C.; Vande Vyvre, P.; von Haller, B.; ALICE Collaboration
2010-04-01
ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). A large bandwidth and flexible Data Acquisition System (DAQ) has been designed and deployed to collect sufficient statistics in the short running time available per year for heavy ions and to accommodate very different requirements originated from the 18 sub-detectors. This paper will present the large scale tests conducted to assess the standalone DAQ performances, the interfaces with the other online systems and the extensive commissioning performed in order to be fully prepared for physics data taking. It will review the experience accumulated since May 2007 during the standalone commissioning of the main detectors and the global cosmic runs and the lessons learned from this exposure on the "battle field". It will also discuss the test protocol followed to integrate and validate each sub-detector with the online systems and it will conclude with the first results of the LHC injection tests and startup in September 2008. Several papers of the same conference present in more details some elements of the ALICE DAQ system.
NASA Astrophysics Data System (ADS)
Chapeland, S.; Carena, F.; Carena, W.; Chibante Barroso, V.; Costa, F.; Dénes, E.; Divià, R.; Fuchs, U.; Grigore, A.; Ionita, C.; Delort, C.; Simonetti, G.; Soós, C.; Telesca, A.; Vande Vyvre, P.; Von Haller, B.; Alice Collaboration
2014-04-01
ALICE (A Large Ion Collider Experiment) is a heavy-ion experiment studying the physics of strongly interacting matter and the quark-gluon plasma at the CERN LHC (Large Hadron Collider). The ALICE DAQ (Data Acquisition System) is based on a large farm of commodity hardware consisting of more than 600 devices (Linux PCs, storage, network switches). The DAQ reads the data transferred from the detectors through 500 dedicated optical links at an aggregated and sustained rate of up to 10 Gigabytes per second and stores at up to 2.5 Gigabytes per second. The infoLogger is the log system which collects centrally the messages issued by the thousands of processes running on the DAQ machines. It allows to report errors on the fly, and to keep a trace of runtime execution for later investigation. More than 500000 messages are stored every day in a MySQL database, in a structured table keeping track for each message of 16 indexing fields (e.g. time, host, user, ...). The total amount of logs for 2012 exceeds 75GB of data and 150 million rows. We present in this paper the architecture and implementation of this distributed logging system, consisting of a client programming API, local data collector processes, a central server, and interactive human interfaces. We review the operational experience during the 2012 run, in particular the actions taken to ensure shifters receive manageable and relevant content from the main log stream. Finally, we present the performance of this log system, and future evolutions.
The new CMS DAQ system for run-2 of the LHC
Bawej, Tomasz; Behrens, Ulf; Branson, James; ...
2015-05-21
The data acquisition (DAQ) system of the CMS experiment at the CERN Large Hadron Collider assembles events at a rate of 100 kHz, transporting event data at an aggregate throughput of 100 GB/s to the high level trigger (HLT) farm. The HLT farm selects interesting events for storage and offline analysis at a rate of around 1 kHz. The DAQ system has been redesigned during the accelerator shutdown in 2013/14. The motivation is twofold: Firstly, the current compute nodes, networking, and storage infrastructure will have reached the end of their lifetime by the time the LHC restarts. Secondly, in ordermore » to handle higher LHC luminosities and event pileup, a number of sub-detectors will be upgraded, increasing the number of readout channels and replacing the off-detector readout electronics with a μTCA implementation. The new DAQ architecture will take advantage of the latest developments in the computing industry. For data concentration, 10/40 Gb/s Ethernet technologies will be used, as well as an implementation of a reduced TCP/IP in FPGA for a reliable transport between custom electronics and commercial computing hardware. A Clos network based on 56 Gb/s FDR Infiniband has been chosen for the event builder with a throughput of ~ 4 Tb/s. The HLT processing is entirely file based. This allows the DAQ and HLT systems to be independent, and to use the HLT software in the same way as for the offline processing. The fully built events are sent to the HLT with 1/10/40 Gb/s Ethernet via network file systems. Hierarchical collection of HLT accepted events and monitoring meta-data are stored into a global file system. As a result, this paper presents the requirements, technical choices, and performance of the new system.« less
artdaq: DAQ software development made simple
NASA Astrophysics Data System (ADS)
Biery, Kurt; Flumerfelt, Eric; Freeman, John; Ketchum, Wesley; Lukhanin, Gennadiy; Rechenmacher, Ron
2017-10-01
For a few years now, the artdaq data acquisition software toolkit has provided numerous experiments with ready-to-use components which allow for rapid development and deployment of DAQ systems. Developed within the Fermilab Scientific Computing Division, artdaq provides data transfer, event building, run control, and event analysis functionality. This latter feature includes built-in support for the art event analysis framework, allowing experiments to run art modules for real-time filtering, compression, disk writing and online monitoring. As art, also developed at Fermilab, is also used for offline analysis, a major advantage of artdaq is that it allows developers to easily switch between developing online and offline software. artdaq continues to be improved. Support for an alternate mode of running whereby data from some subdetector components are only streamed if requested has been added; this option will reduce unnecessary DAQ throughput. Real-time reporting of DAQ metrics has been implemented, along with the flexibility to choose the format through which experiments receive the reports; these formats include the Ganglia, Graphite and syslog software packages, along with flat ASCII files. Additionally, work has been performed investigating more flexible modes of online monitoring, including the capability to run multiple online monitoring processes on different hosts, each running its own set of art modules. Finally, a web-based GUI interface through which users can configure details of their DAQ system has been implemented, increasing the ease of use of the system. Already successfully deployed on the LArlAT, DarkSide-50, DUNE 35ton and Mu2e experiments, artdaq will be employed for SBND and is a strong candidate for use on ICARUS and protoDUNE. With each experiment comes new ideas for how artdaq can be made more flexible and powerful. The above improvements will be described, along with potential ideas for the future.
The design and application of virtual ion meter based on LABVIEW 8.0.
Meng, Hu; Li, Jiangyuan; Tang, Yonghuai
2009-08-01
The virtual ion meter is developed based on LABVIEW 8.0 by homemade adjusting circuit, data acquisition (DAQ) board, and computer. This note provides details of the structure of testing system and flow chart of DAQ program. This virtual instrument system is applied to multitask testing such as determining rate constant of second-order reaction by pX, pX potentiometric titration, determining oscillating reaction by potential, etc. The result of application indicates that this test system not only has function of real-time data acquiring, displaying, storage, but also realizes remote monitoring and controlling test-control spots through internet, automatic analyzing and processing of data, reporting of result according to the different testing task; moreover, the veracity and repeatability of data processing result are higher than the results of manual data processing.
BioDAQ--a simple biosignal acquisition system for didactic use.
Csaky, Z; Mihalas, G I; Focsa, M
2002-01-01
A simple non expensive device for biosignal acquisition is presented. It mainly meets the requirements for didactic purposes specific in medical informatics laboratory classes. The system has two main types of devices: 'student unit'--the simplest one, used during lessons on real signals and 'demo unit', which can be also used in medical practice or for collecting biological signals. It is able to record: optical pulse, sphygmogram, ECG (1-4 leads) EEG or EMG (1-4 channels). For didactical purposes it has a large scale of recording options: variable sampling rate, gain and filtering. It can also be used in tele-acquisition via Internet.
Laser-induced photo emission detection: data acquisition based on light intensity counting
NASA Astrophysics Data System (ADS)
Yulianto, N.; Yudasari, N.; Putri, K. Y.
2017-04-01
Laser Induced Breakdown Detection (LIBD) is one of the quantification techniques for colloids. There are two ways of detection in LIBD: optical detection and acoustic detection. LIBD is based on the detection of plasma emission due to the interaction between particle and laser beam. In this research, the changing of light intensity during plasma formations was detected by a photodiode sensor. A photo emission data acquisition system was built to collect and transform them into digital counts. The real-time system used data acquisition device National Instrument DAQ 6009 and LABVIEW software. The system has been tested on distilled water and tap water samples. The result showed 99.8% accuracy by using counting technique in comparison to the acoustic detection with sample rate of 10 Hz, thus the acquisition system can be applied as an alternative method to the existing LIBD acquisition system.
NASA Astrophysics Data System (ADS)
Mikosch, Jochen; Patchkovskii, Serguei
2013-10-01
We use an analytical theory of noisy Poisson processes, developed in the preceding companion publication, to compare coincidence and covariance measurement approaches in photoelectron and -ion spectroscopy. For non-unit detection efficiencies, coincidence data acquisition (DAQ) suffers from false coincidences. The rate of false coincidences grows quadratically with the rate of elementary ionization events. To minimize false coincidences for rare event outcomes, very low event rates may hence be required. Coincidence measurements exhibit high tolerance to noise introduced by unstable experimental conditions. Covariance DAQ on the other hand is free of systematic errors as long as stable experimental conditions are maintained. In the presence of noise, all channels in a covariance measurement become correlated. Under favourable conditions, covariance DAQ may allow orders of magnitude reduction in measurement times. Finally, we use experimental data for strong-field ionization of 1,3-butadiene to illustrate how fluctuations in experimental conditions can contaminate a covariance measurement, and how such contamination can be detected.
Design of virtual display and testing system for moving mass electromechanical actuator
NASA Astrophysics Data System (ADS)
Gao, Zhigang; Geng, Keda; Zhou, Jun; Li, Peng
2015-12-01
Aiming at the problem of control, measurement and movement virtual display of moving mass electromechanical actuator(MMEA), the virtual testing system of MMEA was developed based on the PC-DAQ architecture and the software platform of LabVIEW, and the comprehensive test task such as drive control of MMEA, tests of kinematic parameter, measurement of centroid position and virtual display of movement could be accomplished. The system could solve the alignment for acquisition time between multiple measurement channels in different DAQ cards, then on this basis, the researches were focused on the dynamic 3D virtual display by the LabVIEW, and the virtual display of MMEA were realized by the method of calling DLL and the method of 3D graph drawing controls. Considering the collaboration with the virtual testing system, including the hardware drive, the measurement software of data acquisition, and the 3D graph drawing controls method was selected, which could obtained the synchronization measurement, control and display. The system can measure dynamic centroid position and kinematic position of movable mass block while controlling the MMEA, and the interface of 3D virtual display has realistic effect and motion smooth, which can solve the problem of display and playback about MMEA in the closed shell.
Multichannel FPGA-Based Data-Acquisition-System for Time-Resolved Synchrotron Radiation Experiments
NASA Astrophysics Data System (ADS)
Choe, Hyeokmin; Gorfman, Semen; Heidbrink, Stefan; Pietsch, Ullrich; Vogt, Marco; Winter, Jens; Ziolkowski, Michael
2017-06-01
The aim of this contribution is to describe our recent development of a novel compact field-programmable gatearray (FPGA)-based data acquisition (DAQ) system for use with multichannel X-ray detectors at synchrotron radiation facilities. The system is designed for time resolved counting of single photons arriving from several-currently 12-independent detector channels simultaneously. Detector signals of at least 2.8 ns duration are latched by asynchronous logic and then synchronized with the system clock of 100 MHz. The incoming signals are subsequently sorted out into 10 000 time-bins where they are counted. This occurs according to the arrival time of photons with respect to the trigger signal. Repeatable mode of triggered operation is used to achieve high statistic of accumulated counts. The time-bin width is adjustable from 10 ns to 1 ms. In addition, a special mode of operation with 2 ns time resolution is provided for two detector channels. The system is implemented in a pocketsize FPGA-based hardware of 10 cm × 10 cm × 3 cm and thus can easily be transported between synchrotron radiation facilities. For setup of operation and data read-out, the hardware is connected via USB interface to a portable control computer. DAQ applications are provided in both LabVIEW and MATLAB environments.
Data acquisition system for the socal plane detector of the mass separator MASHA
NASA Astrophysics Data System (ADS)
Novoselov, A. S.; Rodin, A. M.; Motycak, S.; Podshibyakin, A. V.; Krupa, L.; Belozerov, A. V.; Vedeneyev, V. Yu.; Gulyaev, A. V.; Gulyaeva, A. V.; Kliman, J.; Salamatin, V. S.; Stepantsov, S. V.; Chernysheva, E. V.; Yukhimchuk, S. A.; Komarov, A. B.; Kamas, D.
2016-09-01
The results of the development and the general information about the data acquisition system which was recently created at the MASHA setup (Flerov laboratory of nuclear reactions at Joint institute for nuclear research) are presented. The main difference from the previous system is that we use a new modern platform, National Instruments PXI with XIA multichannel high-speed digitizers (250 MHz 12 bit 16 channels). At this moment system has 448 spectrometric channels. The software and its features for the data acquisition and analysis are also described. The new DAQ system expands precision measuring capabilities of alpha decays and spontaneous fission at the focal plane position-sensitive silicon strip detector which, in turn, increases the capabilities of the setup in such a field as low-yield registration of elements.
A UNIX SVR4-OS 9 distributed data acquisition for high energy physics
NASA Astrophysics Data System (ADS)
Drouhin, F.; Schwaller, B.; Fontaine, J. C.; Charles, F.; Pallares, A.; Huss, D.
1998-08-01
The distributed data acquisition (DAQ) system developed by the GRPHE (Groupe de Recherche en Physique des Hautes Energies) group is a combination of hardware and software dedicated to high energy physics. The system described here is used in the beam tests of the CMS tracker. The central processor of the system is a RISC CPU hosted in a VME card, running a POSIX compliant UNIX system. Specialized real-time OS9 VME cards perform the instrumentation control. The main data flow goes over a deterministic high speed network. The UNIX system manages a list of OS9 front-end systems with a synchronisation protocol running over a TCP/IP layer.
Development of 3He LPSDs and read-out system for the SANS spectrometer at CPHS
NASA Astrophysics Data System (ADS)
Huang, T. C.; Gong, H.; Shao, B. B.; Wang, X. W.; Zhang, Y.; Pang, B. B.
2014-01-01
The Compact Pulsed Hadron Source (CPHS) is a 13-MeV proton-linac-driven neutron source under construction in Tsinghua University. Time-of-flight (TOF) small-angle neutron scattering (SANS) spectrometer is one of the first instruments to be built. It is designed to use linear position-sensitive detectors (LPSDs) of 3He gas proportional counters to cover a 1 m×1 m area. Prototypical LPSDs (Φ = 12 mm, L=1 m) have been made and read-out system is developed based on charge division. This work describes the in-house fabrication of the prototypical LPSDs and design of the read-out system including front-end electronics and data acquisition (DAQ) system. Key factors of the front-end electronics are studied and optimized with PSPICE simulation. DAQ system is designed based on VME bus architecture and FPGA Mezzanine Card (FMC) standard with high flexibility and extendibility. Preliminary experiments are carried out and the results are present and discussed.
The CMS High Level Trigger System: Experience and Future Development
NASA Astrophysics Data System (ADS)
Bauer, G.; Behrens, U.; Bowen, M.; Branson, J.; Bukowiec, S.; Cittolin, S.; Coarasa, J. A.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Flossdorf, A.; Gigi, D.; Glege, F.; Gomez-Reino, R.; Hartl, C.; Hegeman, J.; Holzner, A.; Hwong, Y. L.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Polese, G.; Racz, A.; Raginel, O.; Sakulin, H.; Sani, M.; Schwick, C.; Shpakov, D.; Simon, S.; Spataru, A. C.; Sumorok, K.
2012-12-01
The CMS experiment at the LHC features a two-level trigger system. Events accepted by the first level trigger, at a maximum rate of 100 kHz, are read out by the Data Acquisition system (DAQ), and subsequently assembled in memory in a farm of computers running a software high-level trigger (HLT), which selects interesting events for offline storage and analysis at a rate of order few hundred Hz. The HLT algorithms consist of sequences of offline-style reconstruction and filtering modules, executed on a farm of 0(10000) CPU cores built from commodity hardware. Experience from the operation of the HLT system in the collider run 2010/2011 is reported. The current architecture of the CMS HLT, its integration with the CMS reconstruction framework and the CMS DAQ, are discussed in the light of future development. The possible short- and medium-term evolution of the HLT software infrastructure to support extensions of the HLT computing power, and to address remaining performance and maintenance issues, are discussed.
Developments and applications of DAQ framework DABC v2
NASA Astrophysics Data System (ADS)
Adamczewski-Musch, J.; Kurz, N.; Linev, S.
2015-12-01
The Data Acquisition Backbone Core (DABC) is a software framework for distributed data acquisition. In 2013 Version 2 of DABC has been released with several improvements. For monitoring and control, an HTTP web server and a proprietary command channel socket have been provided. Web browser GUIs have been implemented for configuration and control of DABC and MBS DAQ nodes via such HTTP server. Several specific plug-ins, for example interfacing PEXOR/KINPEX optical readout PCIe boards, or HADES trbnet input and hld file output, have been further developed. In 2014, DABC v2 was applied for production data taking of the HADES collaboration's pion beam time at GSI. It fully replaced the functionality of the previous event builder software and added new features concerning online monitoring.
A Unix SVR-4-OS9 distributed data acquisition for high energy physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drouhin, F.; Schwaller, B.; Fontaine, J.C.
1998-08-01
The distributed data acquisition (DAQ) system developed by the GRPHE (Groupe de Recherche en Physique des Hautes Energies) group is a combination of hardware and software dedicated to high energy physics. The system described here is used in the beam tests of the CMs tracker. The central processor of the system is a RISC CPU hosted in a VME card, running a POSIX compliant UNIX system. Specialized real-time OS9 VME cards perform the instrumentation control. The main data flow goes over a deterministic high speed network. The Unix system manages a list of OS9 front-end systems with a synchronization protocolmore » running over a TCP/IP layer.« less
A Monitoring System for the LHCb Data Flow
NASA Astrophysics Data System (ADS)
Barbosa, João; Gaspar, Clara; Jost, Beat; Frank, Markus; Cardoso, Luis G.
2017-06-01
The LHCb experiment uses the LHC accelerator for the collisions that produce the physics data necessary for analysis. The data produced by the detector by measuring the results of the collisions at a rate of 40 MHz are read out by a complex data acquisition (DAQ) system, which is summarily described in this paper. Distributed systems of such dimensions rely on monitoring and control systems that account for the numerous faults that can happen throughout the whole operation. With this in mind, a new system was created to extend the monitoring of the readout system, in this case by providing an overview of what is happening in each stage of the DAQ process, starting in the hardware trigger performed right after the detector measurements and ending in the local storage of the experiment. This system, a complement to the current run control (experimental control system), intends to shorten reaction times when a problem occurs by providing the operators with detailed information of where a certain fault is occurring. The architecture of the tool and its utilization by the experiment operators are described in this paper.
FPGA-based real-time swept-source OCT systems for B-scan live-streaming or volumetric imaging
NASA Astrophysics Data System (ADS)
Bandi, Vinzenz; Goette, Josef; Jacomet, Marcel; von Niederhäusern, Tim; Bachmann, Adrian H.; Duelk, Marcus
2013-03-01
We have developed a Swept-Source Optical Coherence Tomography (Ss-OCT) system with high-speed, real-time signal processing on a commercially available Data-Acquisition (DAQ) board with a Field-Programmable Gate Array (FPGA). The Ss-OCT system simultaneously acquires OCT and k-clock reference signals at 500MS/s. From the k-clock signal of each A-scan we extract a remap vector for the k-space linearization of the OCT signal. The linear but oversampled interpolation is followed by a 2048-point FFT, additional auxiliary computations, and a data transfer to a host computer for real-time, live-streaming of B-scan or volumetric C-scan OCT visualization. We achieve a 100 kHz A-scan rate by parallelization of our hardware algorithms, which run on standard and affordable, commercially available DAQ boards. Our main development tool for signal analysis as well as for hardware synthesis is MATLAB® with add-on toolboxes and 3rd-party tools.
NASA Astrophysics Data System (ADS)
Suzuki, Soh Yamagata; Yamauchi, Masanori; Nakao, Mikihiko; Itoh, Ryosuke; Fujii, Hirofumi
2000-10-01
We built a data acquisition system for the BELLE experiment. The system was designed to cope with the average trigger rate up to 500 Hz at the typical event size of 30 kB. This system has five components: (1) the readout sequence controller, (2) the FASTBUS-TDC readout systems using charge-to-time conversion, (3) the barrel shifter event builder, (4) the parallel online computing farm, and (5) the data transfer system to the mass storage. This system has been in operation for physics data taking since June 1999 without serious problems.
Data acquisition system for segmented reactor antineutrino detector
NASA Astrophysics Data System (ADS)
Hons, Z.; Vlášek, J.
2017-01-01
This paper describes the data acquisition system used for data readout from the PMT channels of a segmented detector of reactor antineutrinos with active shielding. Theoretical approach to the data acquisition is described and two possible solutions using QDCs and digitizers are discussed. Also described are the results of the DAQ performance during routine data taking operation of DANSS. DANSS (Detector of the reactor AntiNeutrino based on Solid Scintillator) is a project aiming to measure a spectrum of reactor antineutrinos using inverse beta decay (IBD) in a plastic scintillator. The detector is located close to an industrial nuclear reactor core and is covered by passive and active shielding. It is expected to have about 15000 IBD interactions per day. Light from the detector is sensed by PMT and SiPM.
NASA Astrophysics Data System (ADS)
Cho, Young Y.; Chang, Cheng-Chung; Wang, Lihong V.; Zou, Jun
2015-03-01
To achieve real-time photoacoustic tomography (PAT), massive transducer arrays and data acquisition (DAQ) electronics are needed to receive the PA signals simultaneously, which results in complex and high-cost ultrasound receiver systems. To address this issue, we have developed a new PA data acquisition approach using acoustic time delay. Optical fibers were used as parallel acoustic delay lines (PADLs) to create different time delays in multiple channels of PA signals. This makes the PA signals reach a single-element transducer at different times. As a result, they can be properly received by single-channel DAQ electronics. However, due to their small diameter and fragility, using optical fiber as acoustic delay lines poses a number of challenges in the design, construction and packaging of the PADLs, thereby limiting their performances and use in real imaging applications. In this paper, we report the development of new silicon PADLs, which are directly made from silicon wafers using advanced micromachining technologies. The silicon PADLs have very low acoustic attenuation and distortion. A linear array of 16 silicon PADLs were assembled into a handheld package with one common input port and one common output port. To demonstrate its real-time PAT capability, the silicon PADL array (with its output port interfaced with a single-element transducer) was used to receive 16 channels of PA signals simultaneously from a tissue-mimicking optical phantom sample. The reconstructed PA image matches well with the imaging target. Therefore, the silicon PADL array can provide a 16× reduction in the ultrasound DAQ channels for real-time PAT.
USB 3.0 readout and time-walk correction method for Timepix3 detector
NASA Astrophysics Data System (ADS)
Turecek, D.; Jakubek, J.; Soukup, P.
2016-12-01
The hybrid particle counting pixel detectors of Medipix family are well known. In this contribution we present new USB 3.0 based interface AdvaDAQ for Timepix3 detector. The AdvaDAQ interface is designed with a maximal emphasis to the flexibility. It is successor of FitPIX interface developed in IEAP CTU in Prague. Its modular architecture supports all Medipix/Timepix chips and all their different readout modes: Medipix2, Timepix (serial and parallel), Medipix3 and Timepix3. The high bandwidth of USB 3.0 permits readout of 1700 full frames per second with Timepix or 8 channel data acquisition from Timepix3 at frequency of 320 MHz. The control and data acquisition is integrated in a multiplatform PiXet software (MS Windows, Mac OS, Linux). In the second part of the publication a new method for correction of the time-walk effect in Timepix3 is described. Moreover, a fully spectroscopic X-ray imaging with Timepix3 detector operated in the ToT mode (Time-over-Threshold) is presented. It is shown that the AdvaDAQ's readout speed is sufficient to perform spectroscopic measurement at full intensity of radiographic setups equipped with nano- or micro-focus X-ray tubes.
NASA Astrophysics Data System (ADS)
Sato, Tatsuhiko; Satoh, Daiki; Endo, Akira; Shigyo, Nobuhiro; Watanabe, Fusao; Sakurai, Hiroki; Arai, Yoichi
2011-05-01
A dose and spectrum monitoring system applicable to neutrons, photons and muons over wide ranges of energy, designated as DARWIN, has been developed for radiological protection in high-energy accelerator facilities. DARWIN consists of a phoswitch-type scintillation detector, a data-acquisition (DAQ) module for digital waveform analysis, and a personal computer equipped with a graphical-user-interface (GUI) program for controlling the system. The system was recently upgraded by introducing an original DAQ module based on a field programmable gate array, FPGA, and also by adding a function for estimating neutron and photon spectra based on an unfolding technique without requiring any specific scientific background of the user. The performance of the upgraded DARWIN was examined in various radiation fields, including an operational field in J-PARC. The experiments revealed that the dose rates and spectra measured by the upgraded DARWIN are quite reasonable, even in radiation fields with peak structures in terms of both spectrum and time variation. These results clearly demonstrate the usefulness of DARWIN for improving radiation safety in high-energy accelerator facilities.
RapidIO as a multi-purpose interconnect
NASA Astrophysics Data System (ADS)
Baymani, Simaolhoda; Alexopoulos, Konstantinos; Valat, Sébastien
2017-10-01
RapidIO (http://rapidio.org/) technology is a packet-switched high-performance fabric, which has been under active development since 1997. Originally meant to be a front side bus, it developed into a system level interconnect which is today used in all 4G/LTE base stations world wide. RapidIO is often used in embedded systems that require high reliability, low latency and scalability in a heterogeneous environment - features that are highly interesting for several use cases, such as data analytics and data acquisition (DAQ) networks. We will present the results of evaluating RapidIO in a data analytics environment, from setup to benchmark. Specifically, we will share the experience of running ROOT and Hadoop on top of RapidIO. To demonstrate the multi-purpose characteristics of RapidIO, we will also present the results of investigating RapidIO as a technology for high-speed DAQ networks using a generic multi-protocol event-building emulation tool. In addition we will present lessons learned from implementing native ports of CERN applications to RapidIO.
Neutron time-of-flight spectroscopy measurement using a waveform digitizer
NASA Astrophysics Data System (ADS)
Liu, Long-Xiang; Wang, Hong-Wei; Ma, Yu-Gang; Cao, Xi-Guang; Cai, Xiang-Zhou; Chen, Jin-Gen; Zhang, Gui-Lin; Han, Jian-Long; Zhang, Guo-Qiang; Hu, Ji-Feng; Wang, Xiao-He
2016-05-01
The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the Thorium Molten Salt Reactor (TMSR) at the Shanghai Institute of Applied Physics (SINAP). The neutron detector signal used for TOF calculation, with information on the pulse arrival time, pulse shape, and pulse height, was recorded by using a waveform digitizer (WFD). By using the pulse height and pulse-shape discrimination (PSD) analysis to identify neutrons and γ-rays, the neutron TOF spectrum was obtained by employing a simple electronic design, and a new WFD-based DAQ system was developed and tested in this commissioning experiment. The DAQ system developed is characterized by a very high efficiency with respect to millisecond neutron TOF spectroscopy. Supported by Strategic Priority Research Program of the Chinese Academy of Science(TMSR) (XDA02010100), National Natural Science Foundation of China(NSFC)(11475245,No.11305239), Shanghai Key Laboratory of Particle Physics and Cosmology (11DZ2260700)
A potent approach for the development of FPGA based DAQ system for HEP experiments
NASA Astrophysics Data System (ADS)
Khan, Shuaib Ahmad; Mitra, Jubin; David, Erno; Kiss, Tivadar; Nayak, Tapan Kumar
2017-10-01
With ever increasing particle beam energies and interaction rates in modern High Energy Physics (HEP) experiments in the present and future accelerator facilities, there has always been the demand for robust Data Acquisition (DAQ) schemes which perform in the harsh radiation environment and handle high data volume. The scheme is required to be flexible enough to adapt to the demands of future detector and electronics upgrades, and at the same time keeping the cost factor in mind. To address these challenges, in the present work, we discuss an efficient DAQ scheme for error resilient, high speed data communication on commercially available state-of-the-art FPGA with optical links. The scheme utilises GigaBit Transceiver (GBT) protocol to establish radiation tolerant communication link between on-detector front-end electronics situated in harsh radiation environment to the back-end Data Processing Unit (DPU) placed in a low radiation zone. The acquired data are reconstructed in DPU which reduces the data volume significantly, and then transmitted to the computing farms through high speed optical links using 10 Gigabit Ethernet (10GbE). In this study, we focus on implementation and testing of GBT protocol and 10GbE links on an Intel FPGA. Results of the measurements of resource utilisation, critical path delays, signal integrity, eye diagram and Bit Error Rate (BER) are presented, which are the indicators for efficient system performance.
High-speed zero-copy data transfer for DAQ applications
NASA Astrophysics Data System (ADS)
Pisani, Flavio; Cámpora Pérez, Daniel Hugo; Neufeld, Niko
2015-05-01
The LHCb Data Acquisition (DAQ) will be upgraded in 2020 to a trigger-free readout. In order to achieve this goal we will need to connect around 500 nodes with a total network capacity of 32 Tb/s. To get such an high network capacity we are testing zero-copy technology in order to maximize the theoretical link throughput without adding excessive CPU and memory bandwidth overhead, leaving free resources for data processing resulting in less power, space and money used for the same result. We develop a modular test application which can be used with different transport layers. For the zero-copy implementation we choose the OFED IBVerbs API because it can provide low level access and high throughput. We present throughput and CPU usage measurements of 40 GbE solutions using Remote Direct Memory Access (RDMA), for several network configurations to test the scalability of the system.
Future of DAQ Frameworks and Approaches, and Their Evolution towards the Internet of Things
NASA Astrophysics Data System (ADS)
Neufeld, Niko
2015-12-01
Nowadays, a DAQ system is a complex network of processors, sensors and many other active devices. Historically, providing a framework for DAQ has been a very important role of host institutes of experiments. Reviewing evolution of such DAQ frameworks is a very interesting subject of the conference. “Internet of Things” is a recent buzz word but a DAQ framework could be a good example of IoT.
Data Quality Monitoring System for New GEM Muon Detectors for the CMS Experiment Upgrade
NASA Astrophysics Data System (ADS)
King, Robert; CMS Muon Group Team
2017-01-01
The Gas Electron Multiplier (GEM) detectors are novel detectors designed to improve the muon trigger and tracking performance in CMS experiment for the high luminosity upgrade of the LHC. Partial installation of GEM detectors is planned during the 2016-2017 technical stop. Before the GEM system is installed underground, its data acquisition (DAQ) electronics must be thoroughly tested. The DAQ system includes several commercial and custom-built electronic boards running custom firmware. The front-end electronics are radiation-hard and communicate via optical fibers. The data quality monitoring (DQM) software framework has been designed to provide online verification of the integrity of the data produced by the detector electronics, and to promptly identify potential hardware or firmware malfunctions in the system. Local hits reconstruction and clustering algorithms allow quality control of the data produced by each GEM chamber. Once the new detectors are installed, the DQM will monitor the stability and performance of the system during normal data-taking operations. We discuss the design of the DQM system, the software being developed to read out and process the detector data, and the methods used to identify and report hardware and firmware malfunctions of the system.
Timing and Pulse Shape Discrimination Comparison Against Legacy TDC & QDC and the JLab F250 FADC
NASA Astrophysics Data System (ADS)
Milkeris-Zellar, Tyler; Sawatzky, Brad
2017-09-01
The F250 Flash Analog to Digital Convertor (FADC) is a relatively new module used in Data Acquisition Systems (DAQ) at Jefferson Lab. The FADC will replace or supplement older DAQ modules like Time to Digital Converters (TDCs) and Charge Analog to Digital Converters (QDCs). The TDC has a certain known timing resolution and the QDC can integrate a pulse's charge, a feature which can also be used for particle identification between photons and neutrons using pulse shape discrimination (PSD). The focus of this project is developing a test stand to study timing and PSD performance of legacy modules TDC and QDC, and the new F250 FADC. A cosmic telescope was used to extract timing resolution from the TDC and FADC. Through PSD with the QDC and FADC, using a liquid scintillator, we plan to identify photons and neutrons from an americium-beryllium (AmBe) source. Through PSD, we found that the FADC allows for flexible data analysis compared to the QDC. The results indicate that the TDC provides a more accurate measurement of timing resolution than the FADC. This improvement allows for a clear distinction of what module to use when wanting precision of measurement in a DAQ for a cosmic ray telescope. NSF.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, Nur Aira Abd, E-mail: nur-aira@nuclearmalaysia.gov.my; Yussup, Nolida; Ibrahim, Maslina Bt. Mohd
2015-04-29
A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured withmore » a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.« less
Smart pillow for heart-rate monitoring using a fiber optic sensor
NASA Astrophysics Data System (ADS)
Chen, Zhihao; Teo, Ju Teng; Ng, Soon Huat; Yim, Huiqing
2011-03-01
In this paper, we propose and demonstrate a new method to monitor heart rate using fiber optic microbending based sensor for in-bed non-intrusive monitoring. The sensing system consists of transmitter, receiver, sensor mat, National Instrument (NI) data acquisition (DAQ) card and a computer for signal processing. The sensor mat is embedded inside a commercial pillow. The heart rate measurement system shows an accuracy of +/-2 beats, which has been successfully demonstrated in a field trial. The key technological advantage of our system is its ability to measure heart rate with no preparation and minimal compliance by the patient.
NASA Technical Reports Server (NTRS)
Pordes, Ruth (Editor)
1989-01-01
Papers on real-time computer applications in nuclear, particle, and plasma physics are presented, covering topics such as expert systems tactics in testing FASTBUS segment interconnect modules, trigger control in a high energy physcis experiment, the FASTBUS read-out system for the Aleph time projection chamber, a multiprocessor data acquisition systems, DAQ software architecture for Aleph, a VME multiprocessor system for plasma control at the JT-60 upgrade, and a multiasking, multisinked, multiprocessor data acquisition front end. Other topics include real-time data reduction using a microVAX processor, a transputer based coprocessor for VEDAS, simulation of a macropipelined multi-CPU event processor for use in FASTBUS, a distributed VME control system for the LISA superconducting Linac, a distributed system for laboratory process automation, and a distributed system for laboratory process automation. Additional topics include a structure macro assembler for the event handler, a data acquisition and control system for Thomson scattering on ATF, remote procedure execution software for distributed systems, and a PC-based graphic display real-time particle beam uniformity.
Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun
2007-01-01
A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research.
Wang, Wen-Bin; Li, Jang-Yuan; Wu, Qi-Jun
2007-01-01
A LabVIEW-based self-constructed chemical virtual instrument (VI) has been developed for determining temperatures and pressures. It can be put together easily and quickly by selecting hardware modules, such as the PCI-DAQ card or serial port method, different kinds of sensors, signal-conditioning circuits or finished chemical instruments, and software modules such as data acquisition, saving, proceeding. The VI system provides individual and extremely flexible solutions for automatic measurements in physical chemistry research. PMID:17671611
Understanding the Physiological, Biomechanical, and Performance Effects of Body Armor Use
2008-12-01
force plates were collected through a single data acquisition (DAQ) system and were time-synchronized. 2.1 Testing Equipment Figure 1. Examples of 3...For analysis purposes, it was scaled to the volunteer’s body mass (ml/kg/min). For walking trials, the force plate treadmill was set at a speed of...familiarized with walking and running on the force plate treadmill at these speeds. For familiarization, a volunteer first walked at 1.34 mls without any
Real-Time Processing System for the JET Hard X-Ray and Gamma-Ray Profile Monitor Enhancement
NASA Astrophysics Data System (ADS)
Fernandes, Ana M.; Pereira, Rita C.; Neto, André; Valcárcel, Daniel F.; Alves, Diogo; Sousa, Jorge; Carvalho, Bernardo B.; Kiptily, Vasily; Syme, Brian; Blanchard, Patrick; Murari, Andrea; Correia, Carlos M. B. A.; Varandas, Carlos A. F.; Gonçalves, Bruno
2014-06-01
The Joint European Torus (JET) is currently undertaking an enhancement program which includes tests of relevant diagnostics with real-time processing capabilities for the International Thermonuclear Experimental Reactor (ITER). Accordingly, a new real-time processing system was developed and installed at JET for the gamma-ray and hard X-ray profile monitor diagnostic. The new system is connected to 19 CsI(Tl) photodiodes in order to obtain the line-integrated profiles of the gamma-ray and hard X-ray emissions. Moreover, it was designed to overcome the former data acquisition (DAQ) limitations while exploiting the required real-time features. The new DAQ hardware, based on the Advanced Telecommunication Computer Architecture (ATCA) standard, includes reconfigurable digitizer modules with embedded field-programmable gate array (FPGA) devices capable of acquiring and simultaneously processing data in real-time from the 19 detectors. A suitable algorithm was developed and implemented in the FPGAs, which are able to deliver the corresponding energy of the acquired pulses. The processed data is sent periodically, during the discharge, through the JET real-time network and stored in the JET scientific databases at the end of the pulse. The interface between the ATCA digitizers, the JET control and data acquisition system (CODAS), and the JET real-time network is provided by the Multithreaded Application Real-Time executor (MARTe). The work developed allowed attaining two of the major milestones required by next fusion devices: the ability to process and simultaneously supply high volume data rates in real-time.
NASA Astrophysics Data System (ADS)
Bianco, M.; Martoiu, S.; Sidiropoulou, O.; Zibell, A.
2015-12-01
A Micromegas (MM) quadruplet prototype with an active area of 0.5 m2 that adopts the general design foreseen for the upgrade of the innermost forward muon tracking systems (Small Wheels) of the ATLAS detector in 2018-2019, has been built at CERN and is going to be tested in the ATLAS cavern environment during the LHC RUN-II period 2015-2017. The integration of this prototype detector into the ATLAS data acquisition system using custom ATCA equipment is presented. An ATLAS compatible Read Out Driver (ROD) based on the Scalable Readout System (SRS), the Scalable Readout Unit (SRU), will be used in order to transmit the data after generating valid event fragments to the high-level Read Out System (ROS). The SRU will be synchronized with the LHC bunch crossing clock (40.08 MHz) and will receive the Level-1 trigger signals from the Central Trigger Processor (CTP) through the TTCrx receiver ASIC. The configuration of the system will be driven directly from the ATLAS Run Control System. By using the ATLAS TDAQ Software, a dedicated Micromegas segment has been implemented, in order to include the detector inside the main ATLAS DAQ partition. A full set of tests, on the hardware and software aspects, is presented.
Automating spectral measurements
NASA Astrophysics Data System (ADS)
Goldstein, Fred T.
2008-09-01
This paper discusses the architecture of software utilized in spectroscopic measurements. As optical coatings become more sophisticated, there is mounting need to automate data acquisition (DAQ) from spectrophotometers. Such need is exacerbated when 100% inspection is required, ancillary devices are utilized, cost reduction is crucial, or security is vital. While instrument manufacturers normally provide point-and-click DAQ software, an application programming interface (API) may be missing. In such cases automation is impossible or expensive. An API is typically provided in libraries (*.dll, *.ocx) which may be embedded in user-developed applications. Users can thereby implement DAQ automation in several Windows languages. Another possibility, developed by FTG as an alternative to instrument manufacturers' software, is the ActiveX application (*.exe). ActiveX, a component of many Windows applications, provides means for programming and interoperability. This architecture permits a point-and-click program to act as automation client and server. Excel, for example, can control and be controlled by DAQ applications. Most importantly, ActiveX permits ancillary devices such as barcode readers and XY-stages to be easily and economically integrated into scanning procedures. Since an ActiveX application has its own user-interface, it can be independently tested. The ActiveX application then runs (visibly or invisibly) under DAQ software control. Automation capabilities are accessed via a built-in spectro-BASIC language with industry-standard (VBA-compatible) syntax. Supplementing ActiveX, spectro-BASIC also includes auxiliary serial port commands for interfacing programmable logic controllers (PLC). A typical application is automatic filter handling.
Front-end electronics and DAQ for the EURITRACK tagged neutron inspection system
NASA Astrophysics Data System (ADS)
Lunardon, M.; Bottosso, C.; Fabris, D.; Moretto, S.; Nebbia, G.; Pesente, S.; Viesti, G.; Bigongiari, A.; Colonna, A.; Tintori, C.; Valkovic, V.; Sudac, D.; Peerani, P.; Sequeira, V.; Salvato, M.
2007-08-01
The EURopean Illicit TRAfficing Countermeasures Kit (EURITRACK) Front-End and Data Acquisition System is a compact set of VME boards interfaced with a standard PC. The system is part of a cargo container inspection portal based on the tagged neutrons technique. The front-end processes all detector signals and checks coincidences between any of the 64 pixels of the alpha particle detector and any gamma-ray signals in 22 NaI(Tl) scintillators. The system is capable of handling the data flow at neutron flux up to the portal limiting value of 108 neutrons/second. Some typical applications are presented.
NASA Astrophysics Data System (ADS)
Zhang, Hongtao; Fan, Lingling; Wang, Pengfei; Park, Seong-Wook
2012-06-01
A National Instruments (NI) DAQ card PCI 5105 is installed in a high-speed demodulation system based on Fiber Fabry-Pérot Tunable Filter. The instability of the spectra of Fiber Bragg Grating sensors caused by intrinsic drifts of FFP-TF needs an appropriate, flexible trigger. However, the driver of the DAQ card in the current development environment does not provide the functions of analog trigger but digital trigger type. Moreover, the high level of the trigger signal from the tuning voltage of FFP-TF is larger than the maximum input overload voltage of PCI 5105 card. To resolve this incompatibility, a novel converter to change an analog trigger signal into a digital trigger signal has been reported previously. However, the obvious delay time between input and output signals limits the function of demodulation system. Accordingly, we report an improved low-cost, small-size converter with an adjustable delay time. This new scheme can decline the delay time to or close to zero when the frequency of trigger signal is less than 3,000 Hz. This method might be employed to resolve similar problems or to be applied in semiconductor integrated circuits.
Data Acquisition with GPUs: The DAQ for the Muon $g$-$2$ Experiment at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gohn, W.
Graphical Processing Units (GPUs) have recently become a valuable computing tool for the acquisition of data at high rates and for a relatively low cost. The devices work by parallelizing the code into thousands of threads, each executing a simple process, such as identifying pulses from a waveform digitizer. The CUDA programming library can be used to effectively write code to parallelize such tasks on Nvidia GPUs, providing a significant upgrade in performance over CPU based acquisition systems. The muonmore » $g$-$2$ experiment at Fermilab is heavily relying on GPUs to process its data. The data acquisition system for this experiment must have the ability to create deadtime-free records from 700 $$\\mu$$s muon spills at a raw data rate 18 GB per second. Data will be collected using 1296 channels of $$\\mu$$TCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording of the muon decays during the spill. The described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.« less
The TOTEM DAQ based on the Scalable Readout System (SRS)
NASA Astrophysics Data System (ADS)
Quinto, Michele; Cafagna, Francesco S.; Fiergolski, Adrian; Radicioni, Emilio
2018-02-01
The TOTEM (TOTal cross section, Elastic scattering and diffraction dissociation Measurement at the LHC) experiment at LHC, has been designed to measure the total proton-proton cross-section and study the elastic and diffractive scattering at the LHC energies. In order to cope with the increased machine luminosity and the higher statistic required by the extension of the TOTEM physics program, approved for the LHC's Run Two phase, the previous VME based data acquisition system has been replaced with a new one based on the Scalable Readout System. The system features an aggregated data throughput of 2GB / s towards the online storage system. This makes it possible to sustain a maximum trigger rate of ˜ 24kHz, to be compared with the 1KHz rate of the previous system. The trigger rate is further improved by implementing zero-suppression and second-level hardware algorithms in the Scalable Readout System. The new system fulfils the requirements for an increased efficiency, providing higher bandwidth, and increasing the purity of the data recorded. Moreover full compatibility has been guaranteed with the legacy front-end hardware, as well as with the DAQ interface of the CMS experiment and with the LHC's Timing, Trigger and Control distribution system. In this contribution we describe in detail the architecture of full system and its performance measured during the commissioning phase at the LHC Interaction Point.
NASA Astrophysics Data System (ADS)
Aloisio, A.; Cavaliere, S.; Cevenini, F.; Della Volpe, D.; Merola, L.; Anastasio, A.; Fiore, D. J.
KLOE is a general purpose detector optimized to observe CP violation in K0 decays. This detector will be installed at the DAΦNE Φ-factory, in Frascati (Italy) and it is expected to run at the end of 1997. The KLOE DAQ system can be divided mainly into the front-end fast readout section (the Level 1 DAQ), the FDDI Switch and the processor farm. The total bandwidth requirement is estimated to be of the order of 50 Mbyte/s. In this paper, we describe the Level 1 DAQ section, which is based on custom protocols and hardware controllers, developed to achieve high data transfer rates and event building capabilities without software overhead.
The Common Data Acquisition Platform in the Helmholtz Association
NASA Astrophysics Data System (ADS)
Kaever, P.; Balzer, M.; Kopmann, A.; Zimmer, M.; Rongen, H.
2017-04-01
Various centres of the German Helmholtz Association (HGF) started in 2012 to develop a modular data acquisition (DAQ) platform, covering the entire range from detector readout to data transfer into parallel computing environments. This platform integrates generic hardware components like the multi-purpose HGF-Advanced Mezzanine Card or a smart scientific camera framework, adding user value with Linux drivers and board support packages. Technically the scope comprises the DAQ-chain from FPGA-modules to computing servers, notably frontend-electronics-interfaces, microcontrollers and GPUs with their software plus high-performance data transmission links. The core idea is a generic and component-based approach, enabling the implementation of specific experiment requirements with low effort. This so called DTS-platform will support standards like MTCA.4 in hard- and software to ensure compatibility with commercial components. Its capability to deploy on other crate standards or FPGA-boards with PCI express or Ethernet interfaces remains an essential feature. Competences of the participating centres are coordinated in order to provide a solid technological basis for both research topics in the Helmholtz Programme ``Matter and Technology'': ``Detector Technology and Systems'' and ``Accelerator Research and Development''. The DTS-platform aims at reducing costs and development time and will ensure access to latest technologies for the collaboration. Due to its flexible approach, it has the potential to be applied in other scientific programs.
Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard
NASA Astrophysics Data System (ADS)
Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly
2017-08-01
The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period
A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells.
Calderón, Antonio José; González, Isaías; Calderón, Manuel; Segura, Francisca; Andújar, José Manuel
2016-03-09
In this work a new, scalable and low cost multi-channel monitoring system for Polymer Electrolyte Fuel Cells (PEFCs) has been designed, constructed and experimentally validated. This developed monitoring system performs non-intrusive voltage measurement of each individual cell of a PEFC stack and it is scalable, in the sense that it is capable to carry out measurements in stacks from 1 to 120 cells (from watts to kilowatts). The developed system comprises two main subsystems: hardware devoted to data acquisition (DAQ) and software devoted to real-time monitoring. The DAQ subsystem is based on the low-cost open-source platform Arduino and the real-time monitoring subsystem has been developed using the high-level graphical language NI LabVIEW. Such integration can be considered a novelty in scientific literature for PEFC monitoring systems. An original amplifying and multiplexing board has been designed to increase the Arduino input port availability. Data storage and real-time monitoring have been performed with an easy-to-use interface. Graphical and numerical visualization allows a continuous tracking of cell voltage. Scalability, flexibility, easy-to-use, versatility and low cost are the main features of the proposed approach. The system is described and experimental results are presented. These results demonstrate its suitability to monitor the voltage in a PEFC at cell level.
A New, Scalable and Low Cost Multi-Channel Monitoring System for Polymer Electrolyte Fuel Cells
Calderón, Antonio José; González, Isaías; Calderón, Manuel; Segura, Francisca; Andújar, José Manuel
2016-01-01
In this work a new, scalable and low cost multi-channel monitoring system for Polymer Electrolyte Fuel Cells (PEFCs) has been designed, constructed and experimentally validated. This developed monitoring system performs non-intrusive voltage measurement of each individual cell of a PEFC stack and it is scalable, in the sense that it is capable to carry out measurements in stacks from 1 to 120 cells (from watts to kilowatts). The developed system comprises two main subsystems: hardware devoted to data acquisition (DAQ) and software devoted to real-time monitoring. The DAQ subsystem is based on the low-cost open-source platform Arduino and the real-time monitoring subsystem has been developed using the high-level graphical language NI LabVIEW. Such integration can be considered a novelty in scientific literature for PEFC monitoring systems. An original amplifying and multiplexing board has been designed to increase the Arduino input port availability. Data storage and real-time monitoring have been performed with an easy-to-use interface. Graphical and numerical visualization allows a continuous tracking of cell voltage. Scalability, flexibility, easy-to-use, versatility and low cost are the main features of the proposed approach. The system is described and experimental results are presented. These results demonstrate its suitability to monitor the voltage in a PEFC at cell level. PMID:27005630
Process Management inside ATLAS DAQ
NASA Astrophysics Data System (ADS)
Alexandrov, I.; Amorim, A.; Badescu, E.; Burckhart-Chromek, D.; Caprini, M.; Dobson, M.; Duval, P. Y.; Hart, R.; Jones, R.; Kazarov, A.; Kolos, S.; Kotov, V.; Liko, D.; Lucio, L.; Mapelli, L.; Mineev, M.; Moneta, L.; Nassiakou, M.; Pedro, L.; Ribeiro, A.; Roumiantsev, V.; Ryabov, Y.; Schweiger, D.; Soloviev, I.; Wolters, H.
2002-10-01
The Process Management component of the online software of the future ATLAS experiment data acquisition system is presented. The purpose of the Process Manager is to perform basic job control of the software components of the data acquisition system. It is capable of starting, stopping and monitoring the status of those components on the data acquisition processors independent of the underlying operating system. Its architecture is designed on the basis of a server client model using CORBA based communication. The server part relies on C++ software agent objects acting as an interface between the local operating system and client applications. Some of the major design challenges of the software agents were to achieve the maximum degree of autonomy possible, to create processes aware of dynamic conditions in their environment and with the ability to determine corresponding actions. Issues such as the performance of the agents in terms of time needed for process creation and destruction, the scalability of the system taking into consideration the final ATLAS configuration and minimizing the use of hardware resources were also of critical importance. Besides the details given on the architecture and the implementation, we also present scalability and performance tests results of the Process Manager system.
The control system of the multi-strip ionization chamber for the HIMM
NASA Astrophysics Data System (ADS)
Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong
2015-03-01
Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.
NASA Astrophysics Data System (ADS)
HUSEJKO, Michal; EVANS, John; RASTEIRO DA SILVA, Jose Carlos
2015-12-01
High-Level Synthesis (HLS) for Field-Programmable Logic Array (FPGA) programming is becoming a practical alternative to well-established VHDL and Verilog languages. This paper describes a case study in the use of HLS tools to design FPGA-based data acquisition systems (DAQ). We will present the implementation of the CERN CMS detector ECAL Data Concentrator Card (DCC) functionality in HLS and lessons learned from using HLS design flow. The DCC functionality and a definition of the initial system-level performance requirements (latency, bandwidth, and throughput) will be presented. We will describe how its packet processing control centric algorithm was implemented with VHDL and Verilog languages. We will then show how the HLS flow could speed up design-space exploration by providing loose coupling between functions interface design and functions algorithm implementation. We conclude with results of real-life hardware tests performed with the HLS flow-generated design with a DCC Tester system.
Applications of AN OO Methodology and Case to a Daq System
NASA Astrophysics Data System (ADS)
Bee, C. P.; Eshghi, S.; Jones, R.; Kolos, S.; Magherini, C.; Maidantchik, C.; Mapelli, L.; Mornacchi, G.; Niculescu, M.; Patel, A.; Prigent, D.; Spiwoks, R.; Soloviev, I.; Caprini, M.; Duval, P. Y.; Etienne, F.; Ferrato, D.; Le van Suu, A.; Qian, Z.; Gaponenko, I.; Merzliakov, Y.; Ambrosini, G.; Ferrari, R.; Fumagalli, G.; Polesello, G.
The RD13 project has evaluated the use of the Object Oriented Information Engineering (OOIE) method during the development of several software components connected to the DAQ system. The method is supported by a sophisticated commercial CASE tool (Object Management Workbench) and programming environment (Kappa) which covers the full life-cycle of the software including model simulation, code generation and application deployment. This paper gives an overview of the method, CASE tool, DAQ components which have been developed and we relate our experiences with the method and tool, its integration into our development environment and the spiral lifecycle it supports.
The IceCube data acquisition system: Signal capture, digitization, and timestamping
NASA Astrophysics Data System (ADS)
Abbasi, R.; Ackermann, M.; Adams, J.; Ahlers, M.; Ahrens, J.; Andeen, K.; Auffenberg, J.; Bai, X.; Baker, M.; Barwick, S. W.; Bay, R.; Bazo Alba, J. L.; Beattie, K.; Becka, T.; Becker, J. K.; Becker, K.-H.; Berghaus, P.; Berley, D.; Bernardini, E.; Bertrand, D.; Besson, D. Z.; Bingham, B.; Blaufuss, E.; Boersma, D. J.; Bohm, C.; Bolmont, J.; Böser, S.; Botner, O.; Braun, J.; Breeder, D.; Burgess, T.; Carithers, W.; Castermans, T.; Chen, H.; Chirkin, D.; Christy, B.; Clem, J.; Cowen, D. F.; D'Agostino, M. V.; Danninger, M.; Davour, A.; Day, C. T.; Depaepe, O.; De Clercq, C.; Demirörs, L.; Descamps, F.; Desiati, P.; de Vries-Uiterweerd, G.; DeYoung, T.; Diaz-Velez, J. C.; Dreyer, J.; Dumm, J. P.; Duvoort, M. R.; Edwards, W. R.; Ehrlich, R.; Eisch, J.; Ellsworth, R. W.; Engdegård, O.; Euler, S.; Evenson, P. A.; Fadiran, O.; Fazely, A. R.; Feusels, T.; Filimonov, K.; Finley, C.; Foerster, M. M.; Fox, B. D.; Franckowiak, A.; Franke, R.; Gaisser, T. K.; Gallagher, J.; Ganugapati, R.; Gerhardt, L.; Gladstone, L.; Glowacki, D.; Goldschmidt, A.; Goodman, J. A.; Gozzini, R.; Grant, D.; Griesel, T.; Groß, A.; Grullon, S.; Gunasingha, R. M.; Gurtner, M.; Ha, C.; Hallgren, A.; Halzen, F.; Han, K.; Hanson, K.; Hardtke, R.; Hasegawa, Y.; Haugen, J.; Hays, D.; Heise, J.; Helbing, K.; Hellwig, M.; Herquet, P.; Hickford, S.; Hill, G. C.; Hodges, J.; Hoffman, K. D.; Hoshina, K.; Hubert, D.; Huelsnitz, W.; Hughey, B.; Hülß, J.-P.; Hulth, P. O.; Hultqvist, K.; Hussain, S.; Imlay, R. L.; Inaba, M.; Ishihara, A.; Jacobsen, J.; Japaridze, G. S.; Johansson, H.; Jones, A.; Joseph, J. M.; Kampert, K.-H.; Kappes, A.; Karg, T.; Karle, A.; Kawai, H.; Kelley, J. L.; Kiryluk, J.; Kislat, F.; Klein, S. R.; Kleinfelder, S.; Klepser, S.; Kohnen, G.; Kolanoski, H.; Köpke, L.; Kowalski, M.; Kowarik, T.; Krasberg, M.; Kuehn, K.; Kujawski, E.; Kuwabara, T.; Labare, M.; Laihem, K.; Landsman, H.; Lauer, R.; Laundrie, A.; Leich, H.; Leier, D.; Lewis, C.; Lucke, A.; Ludvig, J.; Lundberg, J.; Lünemann, J.; Madsen, J.; Maruyama, R.; Mase, K.; Matis, H. S.; McParland, C. P.; Meagher, K.; Meli, A.; Merck, M.; Messarius, T.; Mészáros, P.; Minor, R. H.; Miyamoto, H.; Mohr, A.; Mokhtarani, A.; Montaruli, T.; Morse, R.; Movit, S. M.; Münich, K.; Muratas, A.; Nahnhauer, R.; Nam, J. W.; Nießen, P.; Nygren, D. R.; Odrowski, S.; Olivas, A.; Olivo, M.; Ono, M.; Panknin, S.; Patton, S.; Pérez de los Heros, C.; Petrovic, J.; Piegsa, A.; Pieloth, D.; Pohl, A. C.; Porrata, R.; Potthoff, N.; Pretz, J.; Price, P. B.; Przybylski, G. T.; Rawlins, K.; Razzaque, S.; Redl, P.; Resconi, E.; Rhode, W.; Ribordy, M.; Rizzo, A.; Robbins, W. J.; Rodrigues, J. P.; Roth, P.; Rothmaier, F.; Rott, C.; Roucelle, C.; Rutledge, D.; Ryckbosch, D.; Sander, H.-G.; Sarkar, S.; Satalecka, K.; Sandstrom, P.; Schlenstedt, S.; Schmidt, T.; Schneider, D.; Schulz, O.; Seckel, D.; Semburg, B.; Seo, S. H.; Sestayo, Y.; Seunarine, S.; Silvestri, A.; Smith, A. J.; Song, C.; Sopher, J. E.; Spiczak, G. M.; Spiering, C.; Stanev, T.; Stezelberger, T.; Stokstad, R. G.; Stoufer, M. C.; Stoyanov, S.; Strahler, E. A.; Straszheim, T.; Sulanke, K.-H.; Sullivan, G. W.; Swillens, Q.; Taboada, I.; Tarasova, O.; Tepe, A.; Ter-Antonyan, S.; Tilav, S.; Tluczykont, M.; Toale, P. A.; Tosi, D.; Turčan, D.; van Eijndhoven, N.; Vandenbroucke, J.; Van Overloop, A.; Viscomi, V.; Vogt, C.; Voigt, B.; Vu, C. Q.; Wahl, D.; Walck, C.; Waldenmaier, T.; Waldmann, H.; Walter, M.; Wendt, C.; Westerhof, S.; Whitehorn, N.; Wharton, D.; Wiebusch, C. H.; Wiedemann, C.; Wikström, G.; Williams, D. R.; Wischnewski, R.; Wissing, H.; Woschnagg, K.; Xu, X. W.; Yodh, G.; Yoshida, S.; IceCube Collaboration
2009-04-01
IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs), detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration is maintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, functional capabilities, and initial performance of the DOM MB, and the operation of a combined array of DOMs as a system, are described here. Experience with the first InIce strings and the IceTop stations indicates that the system design and performance goals have been achieved.
Internal monitoring of GBTx emulator using IPbus for CBM experiment
NASA Astrophysics Data System (ADS)
Mandal, Swagata; Zabolotny, Wojciech; Sau, Suman; Chkrabarti, Amlan; Saini, Jogender; Chattopadhyay, Subhasis; Pal, Sushanta Kumar
2015-09-01
The Compressed Baryonic Matter (CBM) experiment is a part of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt at GSI. In CBM experiment a precisely time synchronized fault tolerant self-triggered electronics is required for Data Acquisition (DAQ) system in CBM experiments which can support high data rate (up to several TB/s). As a part of the implementation of the DAQ system of Muon Chamber (MUCH) which is one of the important detectors in CBM experiment, a FPGA based Gigabit Transceiver (GBTx) emulator is implemented. Readout chain for MUCH consists of XYTER chips (Front end electronics) which will be directly connected to detector, GBTx emulator, Data Processing Board (DPB) and First level event selector board (FLIB) with backend software interface. GBTx emulator will be connected with the XYTER emulator through LVDS (Low Voltage Differential Signalling) line in the front end and in the back end it is connected with DPB through 4.8 Gbps optical link. IPBus over Ethernet is used for internal monitoring of the registers within the GBTx. In IPbus implementation User Datagram Protocol (UDP) stack is used in transport layer of OSI model so that GBTx can be controlled remotely. A Python script is used at computer side to drive IPbus controller.
NASA Astrophysics Data System (ADS)
Hejtmánek, M.; Neue, G.; Voleš, P.
2015-06-01
This article is devoted to the software design and development of a high-speed readout application used for interfacing particle detectors via the CoaXPress communication standard. The CoaXPress provides an asymmetric high-speed serial connection over a single coaxial cable. It uses a widely available 75 Ω BNC standard and can operate in various modes with a data throughput ranging from 1.25 Gbps up to 25 Gbps. Moreover, it supports a low speed uplink with a fixed bit rate of 20.833 Mbps, which can be used to control and upload configuration data to the particle detector. The CoaXPress interface is an upcoming standard in medical imaging, therefore its usage promises long-term compatibility and versatility. This work presents an example of how to develop DAQ system for a pixel detector. For this purpose, a flexible DAQ card was developed using the XILINX Spartan 6 FPGA. The DAQ card is connected to the framegrabber FireBird CXP6 Quad, which is plugged in the PCI Express bus of the standard PC. The data transmission was performed between the FPGA and framegrabber card via the standard coaxial cable in communication mode with a bit rate of 3.125 Gbps. Using the Medipix2 Quad pixel detector, the framerate of 100 fps was achieved. The front-end application makes use of the FireBird framegrabber software development kit and is suitable for data acquisition as well as control of the detector through the registers implemented in the FPGA.
NASA Astrophysics Data System (ADS)
Rankin, Drew J.; Jiang, Jin
2011-04-01
Verification and validation (V&V) of safety control system quality and performance is required prior to installing control system hardware within nuclear power plants (NPPs). Thus, the objective of the hardware-in-the-loop (HIL) platform introduced in this paper is to verify the functionality of these safety control systems. The developed platform provides a flexible simulated testing environment which enables synchronized coupling between the real and simulated world. Within the platform, National Instruments (NI) data acquisition (DAQ) hardware provides an interface between a programmable electronic system under test (SUT) and a simulation computer. Further, NI LabVIEW resides on this remote DAQ workstation for signal conversion and routing between Ethernet and standard industrial signals as well as for user interface. The platform is applied to the testing of a simplified implementation of Canadian Deuterium Uranium (CANDU) shutdown system no. 1 (SDS1) which monitors only the steam generator level of the simulated NPP. CANDU NPP simulation is performed on a Darlington NPP desktop training simulator provided by Ontario Power Generation (OPG). Simplified SDS1 logic is implemented on an Invensys Tricon v9 programmable logic controller (PLC) to test the performance of both the safety controller and the implemented logic. Prior to HIL simulation, platform availability of over 95% is achieved for the configuration used during the V&V of the PLC. Comparison of HIL simulation results to benchmark simulations shows good operational performance of the PLC following a postulated initiating event (PIE).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clockmore » distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.« less
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai; ...
2017-02-01
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. Here, to evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clockmore » distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well.« less
NASA Astrophysics Data System (ADS)
Liu, Hong-Bin; Chen, Hu-Cheng; Chen, Kai; Kierstead, James; Lanni, Francesco; Takai, Helio; Jin, Ge
2017-02-01
ATLAS LAr calorimeter will undergo its Phase-I upgrade during the long shutdown (LS2) in 2018, and a new LAr Trigger Digitizer Board (LTDB) will be designed and installed. Several commercial-off-the-shelf (COTS) multi-channel high-speed ADCs have been selected as possible backups of the radiation tolerant ADC ASICs for the LTDB. To evaluate the radiation tolerance of these backup commercial ADCs, we developed an ADC radiation tolerance characterization system, which includes the ADC boards, data acquisition (DAQ) board, signal generator, external power supplies and a host computer. The ADC board is custom designed for different ADCs, with ADC drivers and clock distribution circuits integrated on board. The Xilinx ZC706 FPGA development board is used as a DAQ board. The data from the ADC are routed to the FPGA through the FMC (FPGA Mezzanine Card) connector, de-serialized and monitored by the FPGA, and then transmitted to the host computer through the Gigabit Ethernet. A software program has been developed with Python, and all the commands are sent to the DAQ board through Gigabit Ethernet by this program. Two ADC boards have been designed for the ADC, ADS52J90 from Texas Instruments and AD9249 from Analog Devices respectively. TID tests for both ADCs have been performed at BNL, and an SEE test for the ADS52J90 has been performed at Massachusetts General Hospital (MGH). Test results have been analyzed and presented. The test results demonstrate that this test system is very versatile, and works well for the radiation tolerance characterization of commercial multi-channel high-speed ADCs for the upgrade of the ATLAS LAr calorimeter. It is applicable to other collider physics experiments where radiation tolerance is required as well. Supported by the U. S. Department of Energy (DE-SC001270)
High-Throughput and Low-Latency Network Communication with NetIO
NASA Astrophysics Data System (ADS)
Schumacher, Jörn; Plessl, Christian; Vandelli, Wainer
2017-10-01
HPC network technologies like Infiniband, TrueScale or OmniPath provide low- latency and high-throughput communication between hosts, which makes them attractive options for data-acquisition systems in large-scale high-energy physics experiments. Like HPC networks, DAQ networks are local and include a well specified number of systems. Unfortunately traditional network communication APIs for HPC clusters like MPI or PGAS exclusively target the HPC community and are not suited well for DAQ applications. It is possible to build distributed DAQ applications using low-level system APIs like Infiniband Verbs, but it requires a non-negligible effort and expert knowledge. At the same time, message services like ZeroMQ have gained popularity in the HEP community. They make it possible to build distributed applications with a high-level approach and provide good performance. Unfortunately, their usage usually limits developers to TCP/IP- based networks. While it is possible to operate a TCP/IP stack on top of Infiniband and OmniPath, this approach may not be very efficient compared to a direct use of native APIs. NetIO is a simple, novel asynchronous message service that can operate on Ethernet, Infiniband and similar network fabrics. In this paper the design and implementation of NetIO is presented and described, and its use is evaluated in comparison to other approaches. NetIO supports different high-level programming models and typical workloads of HEP applications. The ATLAS FELIX project [1] successfully uses NetIO as its central communication platform. The architecture of NetIO is described in this paper, including the user-level API and the internal data-flow design. The paper includes a performance evaluation of NetIO including throughput and latency measurements. The performance is compared against the state-of-the- art ZeroMQ message service. Performance measurements are performed in a lab environment with Ethernet and FDR Infiniband networks.
A Compton suppressed detector multiplicity trigger based digital DAQ for gamma-ray spectroscopy
NASA Astrophysics Data System (ADS)
Das, S.; Samanta, S.; Banik, R.; Bhattacharjee, R.; Basu, K.; Raut, R.; Ghugre, S. S.; Sinha, A. K.; Bhattacharya, S.; Imran, S.; Mukherjee, G.; Bhattacharyya, S.; Goswami, A.; Palit, R.; Tan, H.
2018-06-01
The development of a digitizer based pulse processing and data acquisition system for γ-ray spectroscopy with large detector arrays is presented. The system is based on 250 MHz 12-bit digitizers, and is triggered by a user chosen multiplicity of Compton suppressed detectors. The logic for trigger generation is similar to the one practised for analog (NIM/CAMAC) pulse processing electronics, while retaining the fast processing merits of the digitizer system. Codes for reduction of data acquired from the system have also been developed. The system has been tested with offline studies using radioactive sources as well as in the in-beam experiments with an array of Compton suppressed Clover detectors. The results obtained therefrom validate its use in spectroscopic efforts for nuclear structure investigations.
Modular Integrated Stackable Layers (MISL) 1.1 Design Specification. Design Guideline Document
NASA Technical Reports Server (NTRS)
Yim, Hester J.
2012-01-01
This document establishes the design guideline of the Modular Instrumentation Data Acquisition (MI-DAQ) system in utilization of several designs available in EV. The MI- DAQ provides the options to the customers depending on their system requirements i.e. a 28V interface power supply, a low power battery operated system, a low power microcontroller, a higher performance microcontroller, a USB interface, a Ethernet interface, a wireless communication, various sensor interfaces, etc. Depending on customer's requirements, the each functional board can be stacked up from a bottom level of power supply to a higher level of stack to provide user interfaces. The stack up of boards are accomplished by a predefined and standardized power bus and data bus connections which are included in this document along with other physical and electrical guidelines. This guideline also provides information for a new design options. This specification is the product of a collaboration between NASA/JSC/EV and Texas A&M University. The goal of the collaboration is to open source the specification and allow outside entities to design, build, and market modules that are compatible with the specification. NASA has designed and is using numerous modules that are compatible to this specification. A limited number of these modules will also be released as open source designs to support the collaboration. The released designs are listed in the Applicable Documents.
Removal of anti-Stokes emission background in STED microscopy by FPGA-based synchronous detection
NASA Astrophysics Data System (ADS)
Castello, M.; Tortarolo, G.; Coto Hernández, I.; Deguchi, T.; Diaspro, A.; Vicidomini, G.
2017-05-01
In stimulated emission depletion (STED) microscopy, the role of the STED beam is to de-excite, via stimulated emission, the fluorophores that have been previously excited by the excitation beam. This condition, together with specific beam intensity distributions, allows obtaining true sub-diffraction spatial resolution images. However, if the STED beam has a non-negligible probability to excite the fluorophores, a strong fluorescent background signal (anti-Stokes emission) reduces the effective resolution. For STED scanning microscopy, different synchronous detection methods have been proposed to remove this anti-Stokes emission background and recover the resolution. However, every method works only for a specific STED microscopy implementation. Here we present a user-friendly synchronous detection method compatible with any STED scanning microscope. It exploits a data acquisition (DAQ) card based on a field-programmable gate array (FPGA), which is progressively used in STED microscopy. In essence, the FPGA-based DAQ card synchronizes the fluorescent signal registration, the beam deflection, and the excitation beam interruption, providing a fully automatic pixel-by-pixel synchronous detection method. We validate the proposed method in both continuous wave and pulsed STED microscope systems.
Pedemis: a portable electromagnetic induction sensor with integrated positioning
NASA Astrophysics Data System (ADS)
Barrowes, Benjamin E.; Shubitidze, Fridon; Grzegorczyk, Tomasz M.; Fernández, Pablo; O'Neill, Kevin
2012-06-01
Pedemis (PortablE Decoupled Electromagnetic Induction Sensor) is a time-domain handheld electromagnetic induction (EMI) instrument with the intended purpose of improving the detection and classification of UneXploded Ordnance (UXO). Pedemis sports nine coplanar transmitters (the Tx assembly) and nine triaxial receivers held in a fixed geometry with respect to each other (the Rx assembly) but with that Rx assembly physically decoupled from the Tx assembly allowing flexible data acquisition modes and deployment options. The data acquisition (DAQ) electronics consists of the National Instruments (NI) cRIO platform which is much lighter and more energy efficient that prior DAQ platforms. Pedemis has successfully acquired initial data, and inversion of the data acquired during these initial tests has yielded satisfactory polarizabilities of a spherical target. In addition, precise positioning of the Rx assembly has been achieved via position inversion algorithms based solely on the data acquired from the receivers during the "on-time" of the primary field. Pedemis has been designed to be a flexible yet user friendly EMI instrument that can survey, detect and classify targets in a one pass solution. In this paper, the Pedemis instrument is introduced along with its operation protocols, initial data results, and current status.
NASA Astrophysics Data System (ADS)
Nguyen, Theanh; Chan, Tommy H. T.; Thambiratnam, David P.; King, Les
2015-12-01
In the structural health monitoring (SHM) field, long-term continuous vibration-based monitoring is becoming increasingly popular as this could keep track of the health status of structures during their service lives. However, implementing such a system is not always feasible due to on-going conflicts between budget constraints and the need of sophisticated systems to monitor real-world structures under their demanding in-service conditions. To address this problem, this paper presents a comprehensive development of a cost-effective and flexible vibration DAQ system for long-term continuous SHM of a newly constructed institutional complex with a special focus on the main building. First, selections of sensor type and sensor positions are scrutinized to overcome adversities such as low-frequency and low-level vibration measurements. In order to economically tackle the sparse measurement problem, a cost-optimized Ethernet-based peripheral DAQ model is first adopted to form the system skeleton. A combination of a high-resolution timing coordination method based on the TCP/IP command communication medium and a periodic system resynchronization strategy is then proposed to synchronize data from multiple distributed DAQ units. The results of both experimental evaluations and experimental-numerical verifications show that the proposed DAQ system in general and the data synchronization solution in particular work well and they can provide a promising cost-effective and flexible alternative for use in real-world SHM projects. Finally, the paper demonstrates simple but effective ways to make use of the developed monitoring system for long-term continuous structural health evaluation as well as to use the instrumented building herein as a multi-purpose benchmark structure for studying not only practical SHM problems but also synchronization related issues.
Use of statecharts in the modelling of dynamic behaviour in the ATLAS DAQ prototype-1
NASA Astrophysics Data System (ADS)
Croll, P.; Duval, P.-Y.; Jones, R.; Kolos, S.; Sari, R. F.; Wheeler, S.
1998-08-01
Many applications within the ATLAS DAQ prototype-1 system have complicated dynamic behaviour which can be successfully modelled in terms of states and transitions between states. Previously, state diagrams implemented as finite-state machines have been used. Although effective, they become ungainly as system size increases. Harel statecharts address this problem by implementing additional features such as hierarchy and concurrency. The CHSM object-oriented language system is freeware which implements Harel statecharts as concurrent, hierarchical, finite-state machines (CHSMs). An evaluation of this language system by the ATLAS DAQ group has shown it to be suitable for describing the dynamic behaviour of typical DAQ applications. The language is currently being used to model the dynamic behaviour of the prototype-1 run-control system. The design is specified by means of a CHSM description file, and C++ code is obtained by running the CHSM compiler on the file. In parallel with the modelling work, a code generator has been developed which translates statecharts, drawn using the StP CASE tool, into the CHSM language. C++ code, describing the dynamic behaviour of the run-control system, has been successfully generated directly from StP statecharts using the CHSM generator and compiler. The validity of the design was tested using the simulation features of the Statemate CASE tool.
A Compact, Flexible, High Channel Count DAQ Built From Off-the-Shelf Components
Heffner, M.; Riot, V.; Fabris, L.
2013-06-01
Medium to large channel count detectors are usually faced with a few unattractive options for data acquisition (DAQ). Small to medium sized TPC experiments, for example, can be too small to justify the high expense and long development time of application specific integrated circuit (ASIC) development. In some cases an experiment can piggy-back on a larger experiment and the associated ASIC development, but this puts the time line of development out of the hands of the smaller experiment. Another option is to run perhaps thousands of cables to rack mounted equipment, which is clearly undesirable. The development of commercial high-speedmore » high-density FPGAs and ADCs combined with the small discrete components and robotic assembly open a new option that scales to tens of thousands of channels and is only slightly larger than ASICs using off-the-shelf components.« less
Instrumentation and optimization of intra-cavity fiber laser gas absorption sensing system
NASA Astrophysics Data System (ADS)
Liu, Kun; Liu, Tiegen; Jiang, Junfeng; Liang, Xiao; Zhang, Yimo
2011-11-01
Detection of pollution, inflammable, explosive gases such as methane, acetylene, carbon monoxide and so on is very important for many areas, such as environmental, mining and petrochemical industry. Intra-cavity gas absorption sensing technique (ICGAST) based on Erbium-doped fiber ring laser (EDFRL) is one of novel methods for trace gas with higher precision. It has attracted considerable attention, and many research institutes focus on it. Instrumentation and optimization of ICGAST was reported in this paper. The system consists of five parts, which are variable gain module, intelligent frequency-selection module, gas cell, DAQ module and computer respectively. Variable gain module and intelligent frequency-selection module are combined to establish the intra-cavity of the ring laser. Gas cell is used as gas sensor. DAQ module is used to realize data acquisition synchronously. And gas demodulation is finished in the computer finally. The system was optimized by adjusting the sequence of the components. Take experimental simulation as an example, the absorptance of gas was increased five times after optimization, and the sensitivity enhancement factor can reach more than twenty. By using Fabry-Perot (F-P) etalon, the absorption wavelength of the detected gas can be obtained, with error less than 20 pm. The spectra of the detected gas can be swept continuously to obtain several absorption lines in one loop. The coefficient of variation (CV) was used to show the repeatability of gas concentration detection. And results of CV value can be less than 0.014.
iSANLA: intelligent sensor and actuator network for life science applications.
Schloesser, Mario; Schnitzer, Andreas; Ying, Hong; Silex, Carmen; Schiek, Michael
2008-01-01
In the fields of neurological rehabilitation and neurophysiological research there is a strong need for miniaturized, multi channel, battery driven, wireless networking DAQ systems enabling real-time digital signal processing and feedback experiments. For the scientific investigation on the passive auditory based 3D-orientation of Barn Owls and the scientific research on vegetative locomotor coordination of Parkinson's disease patients during rehabilitation we developed our 'intelligent Sensor and Actuator Network for Life science Application' (iSANLA) system. Implemented on the ultra low power microcontroller MSP430 sample rates up to 96 kHz have been realised for single channel DAQ. The system includes lossless local data storage up to 4 GB. With its outer dimensions of 20mm per rim and less than 15 g of weight including the Lithium-Ion battery our modular designed sensor node is thoroughly capable of up to eight channel recordings with 8 kHz sample rate each and provides sufficient computational power for digital signal processing ready to start our first mobile experiments. For wireless mobility a compact communication protocol based on the IEEE 802.15.4 wireless standard with net data rates up to 141 kbit/s has been implemented. To merge the lossless acquired data of the distributed iNODEs a time synchronization protocol has been developed preserving causality. Hence the necessary time synchronous start of the data acquisition inside a network of multiple sensors with a precision better than the highest sample rate has been realized.
A flexible microcontroller-based data acquisition device.
Hercog, Darko; Gergič, Bojan
2014-06-02
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment.
A versatile scalable PET processing system
DOE Office of Scientific and Technical Information (OSTI.GOV)
H. Dong, A. Weisenberger, J. McKisson, Xi Wenze, C. Cuevas, J. Wilson, L. Zukerman
2011-06-01
Positron Emission Tomography (PET) historically has major clinical and preclinical applications in cancerous oncology, neurology, and cardiovascular diseases. Recently, in a new direction, an application specific PET system is being developed at Thomas Jefferson National Accelerator Facility (Jefferson Lab) in collaboration with Duke University, University of Maryland at Baltimore (UMAB), and West Virginia University (WVU) targeted for plant eco-physiology research. The new plant imaging PET system is versatile and scalable such that it could adapt to several plant imaging needs - imaging many important plant organs including leaves, roots, and stems. The mechanical arrangement of the detectors is designed tomore » accommodate the unpredictable and random distribution in space of the plant organs without requiring the plant be disturbed. Prototyping such a system requires a new data acquisition system (DAQ) and data processing system which are adaptable to the requirements of these unique and versatile detectors.« less
Electronic system for Langmuir probe measurements
NASA Astrophysics Data System (ADS)
Mitov, M.; Bankova, A.; Dimitrova, M.; Ivanova, P.; Tutulkov, K.; Djermanova, N.; Dejarnac, R.; Stöckel, J.; Popov, Tsv K.
2012-03-01
A newly developed Langmuir probe system for measurements of current-voltage (IV) characteristics in the tokamak divertor area is presented and discussed. The system is partially controlled by a computer allowing simultaneous and independent feeding and registration of signals. The system is mounted in the COMPASS tokamak, Institute of Plasma Physics, Academy of Sciences of the Czech Republic. The new electronic circuit boards include also active low-pass filters which smooth the signal before recording by the data acquisition system (DAQ). The signal is thus less noisy and the data processing is much easier. We also designed and built a microcontroller-driven waveform generator with resolution of 1 Ms/s. The power supply is linear and uses a transformer. We avoided the use of a switching power supply because of the noise that it could generate. Examples of measurements of the IV characteristics by divertor probes in the COMPASS tokamak and evaluation of the EEDF are presented.
A high-speed DAQ framework for future high-level trigger and event building clusters
NASA Astrophysics Data System (ADS)
Caselle, M.; Ardila Perez, L. E.; Balzer, M.; Dritschler, T.; Kopmann, A.; Mohr, H.; Rota, L.; Vogelgesang, M.; Weber, M.
2017-03-01
Modern data acquisition and trigger systems require a throughput of several GB/s and latencies of the order of microseconds. To satisfy such requirements, a heterogeneous readout system based on FPGA readout cards and GPU-based computing nodes coupled by InfiniBand has been developed. The incoming data from the back-end electronics is delivered directly into the internal memory of GPUs through a dedicated peer-to-peer PCIe communication. High performance DMA engines have been developed for direct communication between FPGAs and GPUs using "DirectGMA (AMD)" and "GPUDirect (NVIDIA)" technologies. The proposed infrastructure is a candidate for future generations of event building clusters, high-level trigger filter farms and low-level trigger system. In this paper the heterogeneous FPGA-GPU architecture will be presented and its performance be discussed.
In-beam experience with a highly granular DAQ and control network: TrbNet
NASA Astrophysics Data System (ADS)
Michel, J.; Korcyl, G.; Maier, L.; Traxler, M.
2013-02-01
Virtually all Data Acquisition Systems (DAQ) for nuclear and particle physics experiments use a large number of Field Programmable Gate Arrays (FPGAs) for data transport and more complex tasks as pattern recognition and data reduction. All these FPGAs in a large system have to share a common state like a trigger number or an epoch counter to keep the system synchronized for a consistent event/epoch building. Additionally, the collected data has to be transported with high bandwidth, optionally via the ubiquitous Ethernet protocol. Furthermore, the FPGAs' internal states and configuration memories have to be accessed for control and monitoring purposes. Another requirement for a modern DAQ-network is the fault-tolerance for intermittent data errors in the form of automatic retransmission of faulty data. As FPGAs suffer from Single Event Effects when exposed to ionizing particles, the system has to deal with failing FPGAs. The TrbNet protocol was developed taking all these requirements into account. Three virtual channels are merged on one physical medium: The trigger/epoch information is transported with the highest priority. The data channel is second in the priority order, while the control channel is the last. Combined with a small frame size of 80 bit this guarantees a low latency data transport: A system with 100 front-ends can be built with a one-way latency of 2.2 us. The TrbNet-protocol was implemented in each of the 550 FPGAs of the HADES upgrade project and has been successfully used during the Au+Au campaign in April 2012. With 2ṡ106/s Au-ions and 3% interaction ratio the accepted trigger rate is 10 kHz while data is written to storage with 150 MBytes/s. Errors are reliably mitigated via the implemented retransmission of packets and auto-shut-down of individual links. TrbNet was also used for full monitoring of the FEE status. The network stack is written in VHDL and was successfully deployed on various Lattice and Xilinx devices. The TrbNet is also used in other experiments, like systems for detector and electronics development for PANDA and CBM at FAIR. As a platform for such set-ups, e.g. for high-channel time measurement with 15 ps resolution, a generic FPGA platform (TRB3) has been developed.
A data transmission method for particle physics experiments based on Ethernet physical layer
NASA Astrophysics Data System (ADS)
Huang, Xi-Ru; Cao, Ping; Zheng, Jia-Jun
2015-11-01
Due to its advantages of universality, flexibility and high performance, fast Ethernet is widely used in readout system design for modern particle physics experiments. However, Ethernet is usually used together with the TCP/IP protocol stack, which makes it difficult to implement readout systems because designers have to use the operating system to process this protocol. Furthermore, TCP/IP degrades the transmission efficiency and real-time performance. To maximize the performance of Ethernet in physics experiment applications, a data readout method based on the physical layer (PHY) is proposed. In this method, TCP/IP is replaced with a customized and simple protocol, which makes it easier to implement. On each readout module, data from the front-end electronics is first fed into an FPGA for protocol processing and then sent out to a PHY chip controlled by this FPGA for transmission. This kind of data path is fully implemented by hardware. From the side of the data acquisition system (DAQ), however, the absence of a standard protocol causes problems for the network related applications. To solve this problem, in the operating system kernel space, data received by the network interface card is redirected from the traditional flow to a specified memory space by a customized program. This memory space can easily be accessed by applications in user space. For the purpose of verification, a prototype system has been designed and implemented. Preliminary test results show that this method can meet the requirements of data transmission from the readout module to the DAQ with an efficient and simple manner. Supported by National Natural Science Foundation of China (11005107) and Independent Projects of State Key Laboratory of Particle Detection and Electronics (201301)
Design of a novel noninvasive spectrometer for pesticide residues monitor
NASA Astrophysics Data System (ADS)
Ren, Zhong; Liu, Guodong; Huang, Zhen
2014-11-01
Although the gas or liquid chromatography had been widely used into pesticide residues monitoring, some drawbacks such as time-consuming, complicated operation and especially the destructivity for samples were existed. To overcome the limits of destructive detection methods, the noninvasive detection method based on spectroscopy was used to detect the pesticide residues in this paper. To overcome low resolution and light-efficiency due to the drawbacks of the classical plane and holography concave gratings, a novel noninvasive spectrometer for pesticide residues monitor (PRM) based on volume holography transmission (VHT) grating was designed. Meanwhile, a custom-built splitting light system for PRM based on the VHT grating was developed. In addition, the linear charge coupled device (CCD) with combined data acquisition (DAQ) card and the virtual-PRM based on LabVIEW were respectively used as the spectral acquisition hardware and software-platform. Experimental results showed that the spectral resolution of this spectrometer reached 2nm, and the VHT grating's diffraction efficiency was gotten via the simulation experiment.
NASA Astrophysics Data System (ADS)
Monkhoev, R. D.; Budnev, N. M.; Chiavassa, A.; Dyachok, A. N.; Gafarov, A. R.; Gress, O. A.; Gress, T. I.; Grishin, O. G.; Ivanova, A. L.; Kalmykov, N. N.; Kazarina, Yu. A.; Korosteleva, E. E.; Kozhin, V. A.; Kuzmichev, L. A.; Lenok, V. V.; Lubsandorzhiev, B. K.; Lubsandorzhiev, N. B.; Mirgazov, R. R.; Mirzoyan, R.; Osipova, E. A.; Pakhorukov, A. L.; Panasyuk, M. I.; Pankov, L. V.; Poleschuk, V. A.; Popova, E. G.; Postnikov, E. B.; Prosin, V. V.; Ptuskin, V. S.; Pushnin, A. A.; Samoliga, V. S.; Semeney, Y. A.; Sveshnikova, L. G.; Silaev, A. A.; Silaev, A. A., Jr.; Skurikhin, A. V.; Sulakov, V. P.; Tabolenko, V. A.; Voronin, D. M.; Fedorov, O. L.; Spiering, C.; Zagorodnikov, A. V.; Zhurov, D. P.; Zurbanov, V. L.
2017-06-01
The investigation of energy spectrum and mass composition of primary cosmic rays in the energy range 1016-1018 eV and the search for diffuse cosmic gamma rays are of the great interest for understanding mechanisms and nature of high-energy particle sources, the problem of great importance in modern astrophysics. Tunka-Grande scintillator array is a part of the experimental complex TAIGA (Tunka Advanced Instrument for Cosmic Ray and Gamma Astronomy) which is located in the Tunka Valley, about 50 km from Lake Baikal. The purpose of this array is the study of diffuse gamma rays and cosmic rays of ultra-high energies by detecting extensive air showers. We describe the design, specifications of the read-out, data acquisition (DAQ) and control systems of the array.
The Trigger and Data Acquisition System for the 8 tower subsystem of the KM3NeT detector
NASA Astrophysics Data System (ADS)
Manzali, M.; Chiarusi, T.; Favaro, M.; Giacomini, F.; Margiotta, A.; Pellegrino, C.
2016-07-01
KM3NeT is a deep-sea research infrastructure being constructed in the Mediterranean Sea. It will host a large Cherenkov neutrino telescope that will collect photons emitted along the path of the charged particles produced in neutrino interactions in the vicinity of the detector. The philosophy of the DAQ system of the detector foresees that all data are sent to shore after a proper sampling of the photomultiplier signals. No off-shore hardware trigger is implemented and a software selection of the data is performed with an on-line Trigger and Data Acquisition System (TriDAS) to reduce the large throughput due to the environmental light background. A first version of the TriDAS has been developed to operate a prototype detection unit deployed in March 2013 in the abyssal site of Capo Passero (Sicily, Italy), about 3500 m deep. A revised and improved version has been developed to meet the requirements of the final detector, using new tools and modern design solutions. First installation and scalability tests have been performed at the Bologna Common Infrastructure and results comparable to what expected have been observed.
Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance
NASA Astrophysics Data System (ADS)
Setiadi, Rahmondia N.; Schilling, Meinhard
2018-05-01
An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.
Validation of a highly integrated SiPM readout system with a TOF-PET demonstrator
NASA Astrophysics Data System (ADS)
Niknejad, T.; Setayeshi, S.; Tavernier, S.; Bugalho, R.; Ferramacho, L.; Di Francesco, A.; Leong, C.; Rolo, M. D.; Shamshirsaz, M.; Silva, J. C.; Silva, R.; Silveira, M.; Zorraquino, C.; Varela, J.
2016-12-01
We have developed a highly integrated, fast and compact readout electronics for Silicon Photomultiplier (SiPM) based Time of Flight Positron Emission Tomography (TOF-PET) scanners. The readout is based on the use of TOP-PET Application Specific Integrated Circuit (PETsys TOFPET1 ASIC) with 64 channels, each with its amplifier, discriminator, Time to Digital Converter (TDC) and amplitude determination using Time Over Threshold (TOT). The ASIC has 25 ps r.m.s. intrinsic time resolution and fully digital output. The system is optimised for high rates, good timing, low power consumption and low cost. For validating the readout electronics, we have built a technical PET scanner, hereafter called ``demonstrator'', with 2'048 SiPM channels. The PET demonstrator has 16 compact Detector Modules (DM). Each DM has two ASICs reading 128 SiPM pixels in one-to-one coupling to 128 Lutetium Yttrium Orthosilicate (LYSO) crystals measuring 3.1 × 3.1 × 15 mm3 each. The data acquisition system for the demonstrator has two Front End Boards type D (FEB/D), each collecting the data of 1'024 channels (8 DMs), and transmitting assembled data frames through a serial link (4.8 Gbps), to a single Data Acquisition (DAQ) board plugged into the Peripheral Component Interconnect Express (PCIe) bus of the data acquisition PC. Results obtained with this PET demonstrator are presented.
40 Gbps data acquisition system for NectarCAM
NASA Astrophysics Data System (ADS)
Hoffmann, Dirk; Houles, Julien;
2017-10-01
The Cherenkov Telescope Array (CTA) will be the next generation ground-based gamma-ray observatory. It will be made up of approximately 100 telescopes of three different sizes, from 4 to 23 meters in diameter. The previously presented prototype of a high speed data acquisition (DAQ) system for CTA (CHEP 2012, [6]) has become concrete within the NectarCAM project, one of the most challenging camera projects with very demanding needs for bandwidth of data handling. We designed a Linux-PC system able to concentrate and process without packet loss the 40 Gb/s average data rate coming from the 265 Front End Boards (FEB) through Gigabit Ethernet links, and to reduce data to fit the two ten-Gigabit Ethernet downstream links by external trigger decisions as well as custom tailored compression algorithms. Within the given constraints, we implemented de-randomisation of the event fragments received as relatively small UDP packets emitted by the FEB, using off-the-shelf equipment as required by the project and for an operation period of at least 30 years. We tested out-of-the-box interfaces and used original techniques to cope with these requirements, and set up a test bench with hundreds of synchronous Gigabit links in order to validate and tune the acquisition chain including downstream data logging based on zeroMQ and Google ProtocolBuffers [8].
A Flexible Microcontroller-Based Data Acquisition Device
Hercog, Darko; Gergič, Bojan
2014-01-01
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment. PMID:24892494
Man-Portable Vector EMI Sensor for Full UXO Characterization
2012-03-01
receivers (for survey in forest and/or in steep terrain). Left inset shows data acquisition (DAQ) and power unit mounted on a backpack frame. Right panel...survey list was created such as to minimize the overall travel distance to visit every anomaly. After the daily IVS survey field operators walked to...the red star at coordinates (0, 0), is generally offset from the signal peak. This observation motivated use of a conservative 3x3-point-grid survey
500 MHz narrowband beam position monitor electronics for electron synchrotrons
NASA Astrophysics Data System (ADS)
Mohos, I.; Dietrich, J.
1998-12-01
Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bauer, Gerry; et al.
The DAQ system of the CMS experiment at CERN collects data from more than 600 custom detector Front-End Drivers (FEDs). During 2013 and 2014 the CMS DAQ system will undergo a major upgrade to address the obsolescence of current hardware and the requirements posed by the upgrade of the LHC accelerator and various detector components. For a loss-less data collection from the FEDs a new FPGA based card implementing the TCP/IP protocol suite over 10Gbps Ethernet has been developed. To limit the TCP hardware implementation complexity the DAQ group developed a simplified and unidirectional but RFC 793 compliant version ofmore » the TCP protocol. This allows to use a PC with the standard Linux TCP/IP stack as a receiver. We present the challenges and protocol modifications made to TCP in order to simplify its FPGA implementation. We also describe the interaction between the simplified TCP and Linux TCP/IP stack including the performance measurements.« less
Development of new data acquisition system for COMPASS experiment
NASA Astrophysics Data System (ADS)
Bodlak, M.; Frolov, V.; Jary, V.; Huber, S.; Konorov, I.; Levit, D.; Novy, J.; Salac, R.; Virius, M.
2016-04-01
This paper presents development and recent status of the new data acquisiton system of the COMPASS experiment at CERN with up to 50 kHz trigger rate and 36 kB average event size during 10 second period with beam followed by approximately 40 second period without beam. In the original DAQ, the event building is performed by software deployed on switched computer network, moreover the data readout is based on deprecated PCI technology; the new system replaces the event building network with a custom FPGA-based hardware. The custom cards are introduced and advantages of the FPGA technology for DAQ related tasks are discussed. In this paper, we focus on the software part that is mainly responsible for control and monitoring. The most of the system can run as slow control; only readout process has realtime requirements. The design of the software is built on state machines that are implemented using the Qt framework; communication between remote nodes that form the software architecture is based on the DIM library and IPBus technology. Furthermore, PHP and JS languages are used to maintain system configuration; the MySQL database was selected as storage for both configuration of the system and system messages. The system has been design with maximum throughput of 1500 MB/s and large buffering ability used to spread load on readout computers over longer period of time. Great emphasis is put on data latency, data consistency, and even timing checks which are done at each stage of event assembly. System collects results of these checks which together with special data format allows the software to localize origin of problems in data transmission process. A prototype version of the system has already been developed and tested the new system fulfills all given requirements. It is expected that the full-scale version of the system will be finalized in June 2014 and deployed on September provided that tests with cosmic run succeed.
The DISTO data acquisition system at SATURNE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Balestra, F.; Bedfer, Y.; Bertini, R.
1998-06-01
The DISTO collaboration has built a large-acceptance magnetic spectrometer designed to provide broad kinematic coverage of multiparticle final states produced in pp scattering. The spectrometer has been installed in the polarized proton beam of the Saturne accelerator in Saclay to study polarization observables in the {rvec p}p {yields} pK{sup +}{rvec Y} (Y = {Lambda}, {Sigma}{sup 0} or Y{sup *}) reaction and vector meson production ({psi}, {omega} and {rho}) in pp collisions. The data acquisition system is based on a VME 68030 CPU running the OS/9 operating system, housed in a single VME crate together with the CAMAC interface, the triplemore » port ECL memories, and four RISC R3000 CPU. The digitization of signals from the detectors is made by PCOS III and FERA front-end electronics. Data of several events belonging to a single Saturne extraction are stored in VME triple-port ECL memories using a hardwired fast sequencer. The buffer, optionally filtered by the RISC R3000 CPU, is recorded on a DLT cassette by DAQ CPU using the on-board SCSI interface during the acceleration cycle. Two UNIX workstations are connected to the VME CPUs through a fast parallel bus and the Local Area Network. They analyze a subset of events for on-line monitoring. The data acquisition system is able to read and record 3,500 ev/burst in the present configuration with a dead time of 15%.« less
An FPGA-based data acquisition system for directional dark matter detection
NASA Astrophysics Data System (ADS)
Yang, Chen; Nicoloff, Catherine; Sanaullah, Ahmed; Sridhar, Arvind; Herbordt, Martin; Battat, James; Battat Lab at Wellesley College Team; CAAD Lab at Boston University Team
2017-01-01
Directional dark matter detection is a powerful tool in the search for dark matter. Low-pressure gas TPCs are commonly used for directional detection, and dark-matter-induced recoils are mm long. These tracks can be reconstructed by micropatterned readouts. Because large detector volumes are needed, a cost-effective data acquisition system capable of scaling to large channel counts (105 or 106) is required. The Directional Recoil Identification From Tracks (DRIFT) collaboration has pioneered the use of TPCs for directional detection. We employ a negative ion gas with drift speed comparable to the electron drift speed in liquid argon (LAr). We aim to use electronics developed for million-channel readouts in large LAr neutrino detectors. We have built a prototype Micromegas-based directional detector with 103 channels. A FPGA-based back-end system (BE) receives a 12 Gbps data stream from eight ASIC-based front-end boards (FE), each with 128 detector channels. The BE buffers 3 μs of pretrigger data for all channels in DRAM, and streams triggered data to a host PC. We will describe the system architecture and present preliminary measurements from the DAQ. We acknowledge the support of the Research Corporation for Science Advancement, the NSF and the Massachusetts Space Grant Consortium.
The OPERA muon spectrometer tracking electronics
NASA Astrophysics Data System (ADS)
Ambrosio, M.; Barichello, G.; Brugnera, R.; Carrara, E.; Consiglio, L.; Corradi, A.; Dal Corso, F.; Dusini, S.; Felici, G.; Garfagnini, A.; Manea, C.; Masone, V.; Paoloni, A.; Paoluzzi, G.; Papalino, G.; Parascandolo, P.; Sorrentino, G.; Spinetti, M.; Stanco, L.; Terranova, F.; Votano, L.
2004-11-01
The document describes the front-end electronics that instrument the spectrometer of the OPERA experiment. The spectrometer is made of two separate modules. Each module consists of 22 RPC planes equipped with horizontal and vertical strips readout for a total amount of about 25,000 digital channels. The front end electronics is self-triggered and has single plane readout capability. It is made of three different stages: the Front End Boards (FEBs) system, the Controller Boards (CBs) system and the Timing Boards (TBs) system. The FEB system provides discrimination of the strip incoming signals; a FAST OR output of the input signals is also available for trigger plane signal generation. FEBs discriminated signals are acquired by the CBs system that manages also the communication to the experiment DAQ and Slow Control interface. A Trigger Board allows to operate in both self-trigger (the FEB FAST OR signal starts the plane acquisition) or external-trigger (different conditions can be set on the OR signals generated from different planes) modes.
Fan, Shounian; Jiang, Yi; Jiang, Chenxi; Yang, Tianhe; Zhang, Chengyun; Liu, Junshi; Wu, Qiang; Zheng, Yaxi; Liu, Xiaoqiao
2004-10-01
Polygraph has become a necessary instrument in interventional cardiology and fundamental research of medicine up to the present. In this study, a LabView development system (DS) (developed by NI in U.S.) used as software platform, a DAQ data acquisition module and universal computer used as hardware platform, were creatively coupled with our self-made low noise multi-channels preamplifier to develop Multi-channels electrocardiograph. The device possessed the functions such as real time display of physiological process, digit highpass and lowpass, 50Hz filtered and gain adjustment, instant storing, random playback and printing, and process control stimulation. Besides, it was small-sized, economically practical and easy to operate. It could advance the spread of cardiac intervention treatment in hospitals.
Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M.; Manjarrez, Elías; Tapia, Jesús A.; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A.; Herrera-May, Agustín L.
2013-01-01
We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG). PMID:24196434
Juárez-Aguirre, Raúl; Domínguez-Nicolás, Saúl M; Manjarrez, Elías; Tapia, Jesús A; Figueras, Eduard; Vázquez-Leal, Héctor; Aguilera-Cortés, Luz A; Herrera-May, Agustín L
2013-11-05
We present a signal processing system with virtual instrumentation of a MEMS sensor to detect magnetic flux density for biomedical applications. This system consists of a magnetic field sensor, electronic components implemented on a printed circuit board (PCB), a data acquisition (DAQ) card, and a virtual instrument. It allows the development of a semi-portable prototype with the capacity to filter small electromagnetic interference signals through digital signal processing. The virtual instrument includes an algorithm to implement different configurations of infinite impulse response (IIR) filters. The PCB contains a precision instrumentation amplifier, a demodulator, a low-pass filter (LPF) and a buffer with operational amplifier. The proposed prototype is used for real-time non-invasive monitoring of magnetic flux density in the thoracic cage of rats. The response of the rat respiratory magnetogram displays a similar behavior as the rat electromyogram (EMG).
An efficient approach to integrated MeV ion imaging.
Nikbakht, T; Kakuee, O; Solé, V A; Vosuoghi, Y; Lamehi-Rachti, M
2018-03-01
An ionoluminescence (IL) spectral imaging system, besides the common MeV ion imaging facilities such as µ-PIXE and µ-RBS, is implemented at the Van de Graaff laboratory of Tehran. A versatile processing software is required to handle the large amount of data concurrently collected in µ-IL and common MeV ion imaging measurements through the respective methodologies. The open-source freeware PyMca, with image processing and multivariate analysis capabilities, is employed to simultaneously process common MeV ion imaging and µ-IL data. Herein, the program was adapted to support the OM_DAQ listmode data format. The appropriate performance of the µ-IL data acquisition system is confirmed through a case study. Moreover, the capabilities of the software for simultaneous analysis of µ-PIXE and µ-RBS experimental data are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Development and validation of the Overlap Muon Track Finder for the CMS experiment
NASA Astrophysics Data System (ADS)
Dobosz, J.; Mietki, P.; Zawistowski, K.; Żarnecki, G.
2016-09-01
Present article is a description of the authors contribution in upgrade and analysis of performance of the Level-1 Muon Trigger of the CMS experiment. The authors are students of University of Warsaw and Gdansk University of Technology. They are collaborating with the CMS Warsaw Group. This article summarises students' work presented during the Students session during the Workshop XXXVIII-th IEEE-SPIE Joint Symposium Wilga 2016. In the first section the CMS experiment is briefly described and the importance of the trigger system is explained. There is also shown basic difference between old muon trigger strategy and the upgraded one. The second section is devoted to Overlap Muon Track Finder (OMTF). This is one of the crucial components of the Level-1 Muon Trigger. The algorithm of OMTF is described. In the third section there is discussed one of the event selection aspects - cut on the muon transverse momentum pT . Sometimes physical muon with pT bigger than a certain threshold is unnecessarily cut and physical muon with lower pT survives. To improve pT selection modified algorithm was proposed and its performance was studied. One of the features of the OMTF is that one physical muon often results in several muon candidates. The Ghost-Buster algorithm is designed to eliminate surplus candidates. In the fourth section this algorithm and its performance on different data samples are discussed. In the fifth section Local Data Acquisition System (Local DAQ) is briefly described. It supports initial system commissioning. The test done with OMTF Local DAQ are described. In the sixth section there is described development of web application used for the control and monitoring of CMS electronics. The application provides access to graphical user interface for manual control and the connection to the CMS hierarchical Run Control.
MANTA--an open-source, high density electrophysiology recording suite for MATLAB.
Englitz, B; David, S V; Sorenson, M D; Shamma, S A
2013-01-01
The distributed nature of nervous systems makes it necessary to record from a large number of sites in order to decipher the neural code, whether single cell, local field potential (LFP), micro-electrocorticograms (μECoG), electroencephalographic (EEG), magnetoencephalographic (MEG) or in vitro micro-electrode array (MEA) data are considered. High channel-count recordings also optimize the yield of a preparation and the efficiency of time invested by the researcher. Currently, data acquisition (DAQ) systems with high channel counts (>100) can be purchased from a limited number of companies at considerable prices. These systems are typically closed-source and thus prohibit custom extensions or improvements by end users. We have developed MANTA, an open-source MATLAB-based DAQ system, as an alternative to existing options. MANTA combines high channel counts (up to 1440 channels/PC), usage of analog or digital headstages, low per channel cost (<$90/channel), feature-rich display and filtering, a user-friendly interface, and a modular design permitting easy addition of new features. MANTA is licensed under the GPL and free of charge. The system has been tested by daily use in multiple setups for >1 year, recording reliably from 128 channels. It offers a growing list of features, including integrated spike sorting, PSTH and CSD display and fully customizable electrode array geometry (including 3D arrays), some of which are not available in commercial systems. MANTA runs on a typical PC and communicates via TCP/IP and can thus be easily integrated with existing stimulus generation/control systems in a lab at a fraction of the cost of commercial systems. With modern neuroscience developing rapidly, MANTA provides a flexible platform that can be rapidly adapted to the needs of new analyses and questions. Being open-source, the development of MANTA can outpace commercial solutions in functionality, while maintaining a low price-point.
MANTA—an open-source, high density electrophysiology recording suite for MATLAB
Englitz, B.; David, S. V.; Sorenson, M. D.; Shamma, S. A.
2013-01-01
The distributed nature of nervous systems makes it necessary to record from a large number of sites in order to decipher the neural code, whether single cell, local field potential (LFP), micro-electrocorticograms (μECoG), electroencephalographic (EEG), magnetoencephalographic (MEG) or in vitro micro-electrode array (MEA) data are considered. High channel-count recordings also optimize the yield of a preparation and the efficiency of time invested by the researcher. Currently, data acquisition (DAQ) systems with high channel counts (>100) can be purchased from a limited number of companies at considerable prices. These systems are typically closed-source and thus prohibit custom extensions or improvements by end users. We have developed MANTA, an open-source MATLAB-based DAQ system, as an alternative to existing options. MANTA combines high channel counts (up to 1440 channels/PC), usage of analog or digital headstages, low per channel cost (<$90/channel), feature-rich display and filtering, a user-friendly interface, and a modular design permitting easy addition of new features. MANTA is licensed under the GPL and free of charge. The system has been tested by daily use in multiple setups for >1 year, recording reliably from 128 channels. It offers a growing list of features, including integrated spike sorting, PSTH and CSD display and fully customizable electrode array geometry (including 3D arrays), some of which are not available in commercial systems. MANTA runs on a typical PC and communicates via TCP/IP and can thus be easily integrated with existing stimulus generation/control systems in a lab at a fraction of the cost of commercial systems. With modern neuroscience developing rapidly, MANTA provides a flexible platform that can be rapidly adapted to the needs of new analyses and questions. Being open-source, the development of MANTA can outpace commercial solutions in functionality, while maintaining a low price-point. PMID:23653593
DOE Office of Scientific and Technical Information (OSTI.GOV)
Flumerfelt, Eric Lewis
2015-08-01
The NOvA (NuMI Off-axis v e [nu_e] Appearance) Experiment is a long-baseline accelerator neutrino experiment currently in its second year of operations. NOvA uses the Neutrinos from the Main Injector (NuMI) beam at Fermilab, and there are two main off-axis detectors: a Near Detector at Fermilab and a Far Detector 810 km away at Ash River, MN. The work reported herein is in support of the NOvA Experiment, through contributions to the development of data acquisition software, providing an accurate, absolute-scale energy calibration for electromagnetic showers in NOvA detector elements, crucial to the primary electron neutrino search, and through anmore » initial evaluation of the cosmic background rate in the NOvA Far Detector, which is situated on the surface without significant overburden. Additional support work for the NOvA Experiment is also detailed, including DAQ Server Administration duties and a study of NOvA’s sensitivity to neutrino oscillations into a “sterile” state.« less
NASA Astrophysics Data System (ADS)
Shao, Liyang; Zhang, Yunpeng; Li, Zonglei; Zhang, Zhiyong; Zou, Xihua; Luo, Bin; Pan, Wei; Yan, Lianshan
2016-11-01
Logarithmic detectors (LogDs) have been used in coherent Brillouin optical time-domain analysis (BOTDA) sensors to reduce the effect of phase fluctuation, demodulation complexities, and measurement time. However, because of the inherent properties of LogDs, a DC component at the level of hundreds of millivolts that prohibits high-gain signal amplification (SA) could be generated, resulting in unacceptable data acquisition (DAQ) inaccuracies and decoding errors in the process of prototype integration. By generating a reference light at a level similar to the probe light, differential detection can be applied to remove the DC component automatically using a differential amplifier before the DAQ process. Therefore, high-gain SA can be employed to reduce quantization errors. The signal-to-noise ratio of the weak Brillouin gain signal is improved from ˜11.5 to ˜21.8 dB. A BOTDA prototype is implemented based on the proposed scheme. The experimental results show that the measurement accuracy of the Brillouin frequency shift (BFS) is improved from ±1.9 to ±0.8 MHz at the end of a 40-km sensing fiber.
FPGA Based High Speed Data Acquisition System for Electrical Impedance Tomography
Khan, S; Borsic, A; Manwaring, Preston; Hartov, Alexander; Halter, Ryan
2014-01-01
Electrical Impedance Tomography (EIT) systems are used to image tissue bio-impedance. EIT provides a number of features making it attractive for use as a medical imaging device including the ability to image fast physiological processes (>60 Hz), to meet a range of clinical imaging needs through varying electrode geometries and configurations, to impart only non-ionizing radiation to a patient, and to map the significant electrical property contrasts present between numerous benign and pathological tissues. To leverage these potential advantages for medical imaging, we developed a modular 32 channel data acquisition (DAQ) system using National Instruments’ PXI chassis, along with FPGA, ADC, Signal Generator and Timing and Synchronization modules. To achieve high frame rates, signal demodulation and spectral characteristics of higher order harmonics were computed using dedicated FFT-hardware built into the FPGA module. By offloading the computing onto FPGA, we were able to achieve a reduction in throughput required between the FPGA and PC by a factor of 32:1. A custom designed analog front end (AFE) was used to interface electrodes with our system. Our system is wideband, and capable of acquiring data for input signal frequencies ranging from 100 Hz to 12 MHz. The modular design of both the hardware and software will allow this system to be flexibly configured for the particular clinical application. PMID:24729790
Advanced Operating System Technologies
NASA Astrophysics Data System (ADS)
Cittolin, Sergio; Riccardi, Fabio; Vascotto, Sandro
In this paper we describe an R&D effort to define an OS architecture suitable for the requirements of the Data Acquisition and Control of an LHC experiment. Large distributed computing systems are foreseen to be the core part of the DAQ and Control system of the future LHC experiments. Neworks of thousands of processors, handling dataflows of several gigaBytes per second, with very strict timing constraints (microseconds), will become a common experience in the following years. Problems like distributyed scheduling, real-time communication protocols, failure-tolerance, distributed monitoring and debugging will have to be faced. A solid software infrastructure will be required to manage this very complicared environment, and at this moment neither CERN has the necessary expertise to build it, nor any similar commercial implementation exists. Fortunately these problems are not unique to the particle and high energy physics experiments, and the current research work in the distributed systems field, especially in the distributed operating systems area, is trying to address many of the above mentioned issues. The world that we are going to face in the next ten years will be quite different and surely much more interconnected than the one we see now. Very ambitious projects exist, planning to link towns, nations and the world in a single "Data Highway". Teleconferencing, Video on Demend, Distributed Multimedia Applications are just a few examples of the very demanding tasks to which the computer industry is committing itself. This projects are triggering a great research effort in the distributed, real-time micro-kernel based operating systems field and in the software enginering areas. The purpose of our group is to collect the outcame of these different research efforts, and to establish a working environment where the different ideas and techniques can be tested, evaluated and possibly extended, to address the requirements of a DAQ and Control System suitable for LHC. Our work started in the second half of 1994, with a research agreement between CERN and Chorus Systemes (France), world leader in the micro-kernel OS technology. The Chorus OS is targeted to distributed real-time applications, and it can very efficiently support different "OS personalities" in the same environment, like Posix, UNIX, and a CORBA compliant distributed object architecture. Projects are being set-up to verify the suitability of our work for LHC applications, we are building a scaled-down prototype of the DAQ system foreseen for the CMS experiment at LHC, where we will directly test our protocols and where we will be able to make measurements and benchmarks, guiding our development and allowing us to build an analytical model of the system, suitable for simulation and large scale verification.
NASA Astrophysics Data System (ADS)
Yousefzadeh, Hoorvash Camilia; Lecomte, Roger; Fontaine, Réjean
2012-06-01
A fast Wiener filter-based crystal identification (WFCI) algorithm was recently developed to discriminate crystals with close scintillation decay times in phoswich detectors. Despite the promising performance of WFCI, the influence of various physical factors and electrical noise sources of the data acquisition chain (DAQ) on the crystal identification process was not fully investigated. This paper examines the effect of different noise sources, such as photon statistics, avalanche photodiode (APD) excess multiplication noise, and front-end electronic noise, as well as the influence of different shaping filters on the performance of the WFCI algorithm. To this end, a PET-like signal simulator based on a model of the LabPET DAQ, a small animal APD-based digital PET scanner, was developed. Simulated signals were generated under various noise conditions with CR-RC shapers of order 1, 3, and 5 having different time constants (τ). Applying the WFCI algorithm to these simulated signals showed that the non-stationary Poisson photon statistics is the main contributor to the identification error of WFCI algorithm. A shaping filter of order 1 with τ = 50 ns yielded the best WFCI performance (error 1%), while a longer shaping time of τ = 100 ns slightly degraded the WFCI performance (error 3%). Filters of higher orders with fast shaping time constants (10-33 ns) also produced good WFCI results (error 1.4% to 1.6%). This study shows the advantage of the pulse simulator in evaluating various DAQ conditions and confirms the influence of the detection chain on the WFCI performance.
NASA Astrophysics Data System (ADS)
Fontana, Cristiano Lino; Carnera, Alberto; Lunardon, Marcello; Pino, Felix; Sada, Cinzia; Soramel, Francesca; Stevanato, Luca; Nebbia, Giancarlo; Carasco, Cédric; Perot, Bertrand; Sardet, Alix; Sannie, Guillaume; Iovene, Alessandro; Tintori, Carlo; Grodzicki, Krystian; Moszyński, Marek; Sibczyński, Paweł; Swiderski, Lukasz; Moretto, Sandra
The European project entitled ;effective Container inspection at BORDer control points; (C-BORD) focuses on the development and in-situ tests of a comprehensive cost-effective solution for the generalized Non-Intrusive Inspection (NII) of containers and large-volume freight at the European Union (EU) border. It copes with a large range of targets, including explosives, chemical warfare agents, illicit drugs, tobacco and Special Nuclear Materials. Within the C-BORD project, a new generation of Tagged Neutron Inspection System (TNIS) for cargo containers is foreseen. Unlike its predecessors, this system would be the first Rapidly Relocatable TNIS (RRTNIS). It will be a second-line defense system, to be used on sealed containers in order to detect explosives, illicit drugs and chemical agents in a suspect voxel (elementary volume unit). We report on the status of the RRTNIS system, in particular the overall design, the characterization of the large-volume NaI(Tl) gamma detectors, the digital analysis of the time measurements and the Data Acquisition System (DAQ).
Analysis and application of two-current-source circuit as a signal conditioner for resistive sensors
NASA Astrophysics Data System (ADS)
Idzkowski, Adam; Gołębiowski, Jerzy; Walendziuk, Wojciech
2017-05-01
The article presents the analysis of metrological properties of a two-current-source supplied circuit. It includes such data as precise and simplified equations for two circuit output voltages in the function of relative resistance increments of sensors. Moreover, graphs showing nonlinearity coefficients of both output voltages for two resistance increments varying widely are presented. Graphs of transfer resistances, depending on relative increments of sensors resistance were also created. The article also contains a description of bridge-based circuit realization with the use of a computer and a data acquisition (DAQ) card. Laboratory measurement of the difference and sum of relative resistance increments of two resistance decade boxes were carried out indirectly with the use of the created measurement system. Measurement errors were calculated and included in the article, as well.
NASA Technical Reports Server (NTRS)
Thomas, Randy; Stueber, Thomas J.
2013-01-01
The System Identification (SysID) Rack is a real-time hardware-in-the-loop data acquisition (DAQ) and control instrument rack that was designed and built to support inlet testing in the NASA Glenn Research Center 10- by 10-Foot Supersonic Wind Tunnel. This instrument rack is used to support experiments on the Combined-Cycle Engine Large-Scale Inlet for Mode Transition Experiment (CCE? LIMX). The CCE?LIMX is a testbed for an integrated dual flow-path inlet configuration with the two flow paths in an over-and-under arrangement such that the high-speed flow path is located below the lowspeed flow path. The CCE?LIMX includes multiple actuators that are designed to redirect airflow from one flow path to the other; this action is referred to as "inlet mode transition." Multiple phases of experiments have been planned to support research that investigates inlet mode transition: inlet characterization (Phase-1) and system identification (Phase-2). The SysID Rack hardware design met the following requirements to support Phase-1 and Phase-2 experiments: safely and effectively move multiple actuators individually or synchronously; sample and save effector control and position sensor feedback signals; automate control of actuator positioning based on a mode transition schedule; sample and save pressure sensor signals; and perform DAQ and control processes operating at 2.5 KHz. This document describes the hardware components used to build the SysID Rack including their function, specifications, and system interface. Furthermore, provided in this document are a SysID Rack effectors signal list (signal flow); system identification experiment setup; illustrations indicating a typical SysID Rack experiment; and a SysID Rack performance overview for Phase-1 and Phase-2 experiments. The SysID Rack described in this document was a useful tool to meet the project objectives.
Khan, Shadab; Manwaring, Preston; Borsic, Andrea; Halter, Ryan
2015-04-01
Electrical impedance tomography (EIT) is used to image the electrical property distribution of a tissue under test. An EIT system comprises complex hardware and software modules, which are typically designed for a specific application. Upgrading these modules is a time-consuming process, and requires rigorous testing to ensure proper functioning of new modules with the existing ones. To this end, we developed a modular and reconfigurable data acquisition (DAQ) system using National Instruments' (NI) hardware and software modules, which offer inherent compatibility over generations of hardware and software revisions. The system can be configured to use up to 32-channels. This EIT system can be used to interchangeably apply current or voltage signal, and measure the tissue response in a semi-parallel fashion. A novel signal averaging algorithm, and 512-point fast Fourier transform (FFT) computation block was implemented on the FPGA. FFT output bins were classified as signal or noise. Signal bins constitute a tissue's response to a pure or mixed tone signal. Signal bins' data can be used for traditional applications, as well as synchronous frequency-difference imaging. Noise bins were used to compute noise power on the FPGA. Noise power represents a metric of signal quality, and can be used to ensure proper tissue-electrode contact. Allocation of these computationally expensive tasks to the FPGA reduced the required bandwidth between PC, and the FPGA for high frame rate EIT. In 16-channel configuration, with a signal-averaging factor of 8, the DAQ frame rate at 100 kHz exceeded 110 frames s (-1), and signal-to-noise ratio exceeded 90 dB across the spectrum. Reciprocity error was found to be for frequencies up to 1 MHz. Static imaging experiments were performed on a high-conductivity inclusion placed in a saline filled tank; the inclusion was clearly localized in the reconstructions obtained for both absolute current and voltage mode data.
A new ATLAS muon CSC readout system with system on chip technology on ATCA platform
NASA Astrophysics Data System (ADS)
Claus, R.; ATLAS Collaboration
2016-07-01
The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. The full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.
A new ATLAS muon CSC readout system with system on chip technology on ATCA platform
NASA Astrophysics Data System (ADS)
Bartoldus, R.; Claus, R.; Garelli, N.; Herbst, R. T.; Huffer, M.; Iakovidis, G.; Iordanidou, K.; Kwan, K.; Kocian, M.; Lankford, A. J.; Moschovakos, P.; Nelson, A.; Ntekas, K.; Ruckman, L.; Russell, J.; Schernau, M.; Schlenker, S.; Su, D.; Valderanis, C.; Wittgen, M.; Yildiz, S. C.
2016-01-01
The ATLAS muon Cathode Strip Chamber (CSC) backend readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run-2 luminosity. The readout design is based on the Reconfigurable Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the Advanced Telecommunication Computing Architecture (ATCA) platform. The RCE design is based on the new System on Chip XILINX ZYNQ series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources. Together with auxiliary memories, all these components form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the ZYNQ for high speed input and output fiberoptic links and TTC allowed the full system of 320 input links from the 32 chambers to be processed by 6 COBs in one ATCA shelf. The full system was installed in September 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning for LHC Run 2.
A new ATLAS muon CSC readout system with system on chip technology on ATCA platform
Bartoldus, R.; Claus, R.; Garelli, N.; ...
2016-01-25
The ATLAS muon Cathode Strip Chamber (CSC) backend readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run-2 luminosity. The readout design is based on the Reconfigurable Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the Advanced Telecommunication Computing Architecture (ATCA) platform. The RCE design is based on the new System on Chip XILINX ZYNQ series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources. Together with auxiliary memories, all ofmore » these components form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the ZYNQ for high speed input and output fiberoptic links and TTC allowed the full system of 320 input links from the 32 chambers to be processed by 6 COBs in one ATCA shelf. The full system was installed in September 2014. In conclusion, we will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning for LHC Run 2.« less
The Influence of the Density of Coconut Fiber as Stack in Thermo-Acoustics Refrigeration System
NASA Astrophysics Data System (ADS)
Hartulistiyoso, E.; Yulianto, M.; Sucahyo, L.
2018-05-01
An experimental study of using coconut fiber as stack with varying density in thermo-acoustics refrigeration system has been done. Stack is a device which is described as the “heart” in thermo-acoustics refrigeration system. The length of stack is a fix parameter in this experiment. The performance of the coconut fiber was evaluated from the density of stack (varied from 30%, 50% and 70%), position of stack (varied from 0 to 34 cm from the sound generator), and frequency of sound generator (varied from 150 Hz, 200Hz, 250Hz and 300Hz). The inside, outside, and environment temperatures were collected every second using Data Acquisition (DAQ). The result showed that the increase of stack density will increase the performance of thermo-acoustics refrigeration system. The higher density produced temperature differences in cold side and hot side of 5.4°C. In addition, the position of stack and frequency of sound generator have an important role in the performance of thermo-acoustics refrigeration system for all variations of the density.
ArControl: An Arduino-Based Comprehensive Behavioral Platform with Real-Time Performance.
Chen, Xinfeng; Li, Haohong
2017-01-01
Studying animal behavior in the lab requires reliable delivering stimulations and monitoring responses. We constructed a comprehensive behavioral platform (ArControl: Arduino Control Platform) that was an affordable, easy-to-use, high-performance solution combined software and hardware components. The hardware component was consisted of an Arduino UNO board and a simple drive circuit. As for software, the ArControl provided a stand-alone and intuitive GUI (graphical user interface) application that did not require users to master scripts. The experiment data were automatically recorded with the built in DAQ (data acquisition) function. The ArControl also allowed the behavioral schedule to be entirely stored in and operated on the Arduino chip. This made the ArControl a genuine, real-time system with high temporal resolution (<1 ms). We tested the ArControl, based on strict performance measurements and two mice behavioral experiments. The results showed that the ArControl was an adaptive and reliable system suitable for behavioral research.
ArControl: An Arduino-Based Comprehensive Behavioral Platform with Real-Time Performance
Chen, Xinfeng; Li, Haohong
2017-01-01
Studying animal behavior in the lab requires reliable delivering stimulations and monitoring responses. We constructed a comprehensive behavioral platform (ArControl: Arduino Control Platform) that was an affordable, easy-to-use, high-performance solution combined software and hardware components. The hardware component was consisted of an Arduino UNO board and a simple drive circuit. As for software, the ArControl provided a stand-alone and intuitive GUI (graphical user interface) application that did not require users to master scripts. The experiment data were automatically recorded with the built in DAQ (data acquisition) function. The ArControl also allowed the behavioral schedule to be entirely stored in and operated on the Arduino chip. This made the ArControl a genuine, real-time system with high temporal resolution (<1 ms). We tested the ArControl, based on strict performance measurements and two mice behavioral experiments. The results showed that the ArControl was an adaptive and reliable system suitable for behavioral research. PMID:29321735
BETA (Bitter Electromagnet Testing Apparatus) Design and Testing
NASA Astrophysics Data System (ADS)
Bates, Evan; Birmingham, William; Rivera, William; Romero-Talamas, Carlos
2016-10-01
BETA is a 1T water cooled Bitter-type magnetic system that has been designed and constructed at the Dusty Plasma Laboratory of the University of Maryland, Baltimore County to serve as a prototype of a scaled 10T version. Currently the system is undergoing magnetic, thermal and mechanical testing to ensure safe operating conditions and to prove analytical design optimizations. These magnets will function as experimental tools for future dusty plasma based and collaborative experiments. An overview of design methods used for building a custom made Bitter magnet with user defined experimental constraints is reviewed. The three main design methods consist of minimizing the following: ohmic power, peak conductor temperatures, and stresses induced by Lorentz forces. We will also discuss the design of BETA which includes: the magnet core, pressure vessel, cooling system, power storage bank, high powered switching system, diagnostics with safety cutoff feedback, and data acquisition (DAQ)/magnet control Matlab code. Furthermore, we present experimental data from diagnostics for validation of our analytical preliminary design methodologies and finite element analysis calculations. BETA will contribute to the knowledge necessary to finalize the 10 T magnet design.
Free-running ADC- and FPGA-based signal processing method for brain PET using GAPD arrays
NASA Astrophysics Data System (ADS)
Hu, Wei; Choi, Yong; Hong, Key Jo; Kang, Jihoon; Jung, Jin Ho; Huh, Youn Suk; Lim, Hyun Keong; Kim, Sang Su; Kim, Byung-Tae; Chung, Yonghyun
2012-02-01
Currently, for most photomultiplier tube (PMT)-based PET systems, constant fraction discriminators (CFD) and time to digital converters (TDC) have been employed to detect gamma ray signal arrival time, whereas anger logic circuits and peak detection analog-to-digital converters (ADCs) have been implemented to acquire position and energy information of detected events. As compared to PMT the Geiger-mode avalanche photodiodes (GAPDs) have a variety of advantages, such as compactness, low bias voltage requirement and MRI compatibility. Furthermore, the individual read-out method using a GAPD array coupled 1:1 with an array scintillator can provide better image uniformity than can be achieved using PMT and anger logic circuits. Recently, a brain PET using 72 GAPD arrays (4×4 array, pixel size: 3 mm×3 mm) coupled 1:1 with LYSO scintillators (4×4 array, pixel size: 3 mm×3 mm×20 mm) has been developed for simultaneous PET/MRI imaging in our laboratory. Eighteen 64:1 position decoder circuits (PDCs) were used to reduce GAPD channel number and three off-the-shelf free-running ADC and field programmable gate array (FPGA) combined data acquisition (DAQ) cards were used for data acquisition and processing. In this study, a free-running ADC- and FPGA-based signal processing method was developed for the detection of gamma ray signal arrival time, energy and position information all together for each GAPD channel. For the method developed herein, three DAQ cards continuously acquired 18 channels of pre-amplified analog gamma ray signals and 108-bit digital addresses from 18 PDCs. In the FPGA, the digitized gamma ray pulses and digital addresses were processed to generate data packages containing pulse arrival time, baseline value, energy value and GAPD channel ID. Finally, these data packages were saved to a 128 Mbyte on-board synchronous dynamic random access memory (SDRAM) and then transferred to a host computer for coincidence sorting and image reconstruction. In order to evaluate the functionality of the developed signal processing method, energy and timing resolutions for brain PET were measured via the placement of a 6 μCi 22Na point source at the center of the PET scanner. Furthermore the PET image of the hot rod phantom (rod diameter: from 2.5 mm to 6.5 mm) with activity of 1 mCi was simulated, and then image acquisition experiment was performed using the brain PET. Measured average energy resolution for 1152 GAPD channels and system timing resolution were 19.5% (FWHM%) and 2.7 ns (FWHM), respectively. With regard to the acquisition of the hot rod phantom image, rods could be resolved down to a diameter of 2.5 mm, which was similar to simulated results. The experimental results demonstrated that the signal processing method developed herein was successfully implemented for brain PET. This reduced the complexity, cost and developing duration for PET system relative to normal PET electronics, and it will obviously be useful for the development of high-performance investigational PET systems.
Development of an integrated digital hand grip dynamometer and norm of hand grip strength.
Chang, Ho; Chen, Chih-Hao; Huang, Tung-Sun; Tai, Chun-Yen
2015-01-01
This study designs and fabricates a novel integrated digital hand grip dynamometer and analyzes collected grip strength data. The dynamometer directly stores collected data in a computer, unlike those on the market that cannot directly store information. A strain gauge load cell is used as a force sensor. The dynamometer is designed to maximize ergonomics. Excitation voltage of the load cell is 5 V, and a 9 V battery supplies power to its circuit. The signal receiver is National Instruments (NI) data acquisition (DAQ) card that transmits signals to the computer. The operation system is designed using LabView. This study assesses the correlation between variables of collected data. The correlation coefficients for height, weight and palm length were 0.793, 0.609 and 0.715, respectively, indicating that variables were moderately to strongly correlate with grip strength.
The CMS Data Acquisition - Architectures for the Phase-2 Upgrade
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Behrens, U.; Branson, J.; Brummer, P.; Chaze, O.; Cittolin, S.; Contescu, C.; Craigs, B. G.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Doualot, N.; Erhan, S.; Fulcher, J. F.; Gigi, D.; Gładki, M.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Janulis, M.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; O'Dell, V.; Orsini, L.; Paus, C.; Petrova, P.; Pieri, M.; Racz, A.; Reis, T.; Sakulin, H.; Schwick, C.; Simelevicius, D.; Zejdl, P.
2017-10-01
The upgraded High Luminosity LHC, after the third Long Shutdown (LS3), will provide an instantaneous luminosity of 7.5 × 1034 cm-2 s -1 (levelled), at the price of extreme pileup of up to 200 interactions per crossing. In LS3, the CMS Detector will also undergo a major upgrade to prepare for the phase-2 of the LHC physics program, starting around 2025. The upgraded detector will be read out at an unprecedented data rate of up to 50 Tb/s and an event rate of 750 kHz. Complete events will be analysed by software algorithms running on standard processing nodes, and selected events will be stored permanently at a rate of up to 10 kHz for offline processing and analysis. In this paper we discuss the baseline design of the DAQ and HLT systems for the phase-2, taking into account the projected evolution of high speed network fabrics for event building and distribution, and the anticipated performance of general purpose CPU. Implications on hardware and infrastructure requirements for the DAQ “data center” are analysed. Emerging technologies for data reduction are considered. Novel possible approaches to event building and online processing, inspired by trending developments in other areas of computing dealing with large masses of data, are also examined. We conclude by discussing the opportunities offered by reading out and processing parts of the detector, wherever the front-end electronics allows, at the machine clock rate (40 MHz). This idea presents interesting challenges and its physics potential should be studied.
The CMS Data Acquisition - Architectures for the Phase-2 Upgrade
Andre, J-M; Behrens, U.; Branson, J.; ...
2017-10-01
The upgraded High Luminosity LHC, after the third Long Shutdown (LS3), will provide an instantaneous luminosity of 7.5 × 10 34 cm -2 s -1 (levelled), at the price of extreme pileup of up to 200 interactions per crossing. In LS3, the CMS Detector will also undergo a major upgrade to prepare for the phase-2 of the LHC physics program, starting around 2025. The upgraded detector will be read out at an unprecedented data rate of up to 50 Tb/s and an event rate of 750 kHz. Complete events will be analysed by software algorithms running on standard processing nodes,more » and selected events will be stored permanently at a rate of up to 10 kHz for offline processing and analysis. Here in this paper we discuss the baseline design of the DAQ and HLT systems for the phase-2, taking into account the projected evolution of high speed network fabrics for event building and distribution, and the anticipated performance of general purpose CPU. Implications on hardware and infrastructure requirements for the DAQ “data center” are analysed. Emerging technologies for data reduction are considered. Novel possible approaches to event building and online processing, inspired by trending developments in other areas of computing dealing with large masses of data, are also examined. We conclude by discussing the opportunities offered by reading out and processing parts of the detector, wherever the front-end electronics allows, at the machine clock rate (40 MHz). This idea presents interesting challenges and its physics potential should be studied.« less
NASA Astrophysics Data System (ADS)
Masi, Matteo; Ferdos, Farzad; Losito, Gabriella; Solari, Luca
2016-04-01
Electrical Impedance Tomography (EIT) is a technique for the imaging of the electrical properties of conductive materials. In EIT, the spatial distribution of the electrical resistivity or electrical conductivity within a domain is reconstructed using measurements made with electrodes placed at the boundaries of the domain. Data acquisition is typically made by applying an electrical current to the object under investigation using a set of electrodes, and measuring the developed voltage between the other electrodes. The tomographic image is then obtained using an inversion algorithm. This work describes the implementation of a simple and low cost 3D EIT measurement system suitable for laboratory-scale studies. The system was specifically developed for the time-lapse imaging of soil samples subjected to erosion processes during laboratory tests. The tests reproduce the process of internal erosion of soil particles by water flow within a granular media; this process is one of the most common causes of failure of earthen levees and embankment dams. The measurements needed strict requirements of speed and accuracy due to the varying time scale and magnitude of these processes. The developed EIT system consists of a PC which controls I/O cards (multiplexers) through the Arduino micro-controller, an external current generator, a digital acquisition device (DAQ), a power supply and the electrodes. The ease of programming of the Arduino interface greatly helped the implementation of custom acquisition software, increasing the overall flexibility of the system and the creation of specific acquisition schemes and configurations. The system works with a multi-electrode configuration of up to 48 channels but it was designed to be upgraded to an arbitrary large number of electrodes by connecting additional multiplexer cards (> 96 electrodes). The acquisition was optimized for multi-channel measurements so that the overall time of acquisition is dramatically reduced compared to the single channel instrumentation. The accuracy and operation were tested under different conditions. The results from preliminary tests show that the system is able to clearly identify objects discriminated by different resistivity. Furthermore, measurements carried out during internal erosion simulations demonstrate that even small variations in the electrical resistivity can be captured and these changes can be related to the erosion processes.
Multidetector system for nanosecond tagged neutron technology based on hardware selection of events
NASA Astrophysics Data System (ADS)
Karetnikov, M. D.; Korotkov, S. A.; Khasaev, T. O.
2016-09-01
At the T( d, n)He4 reaction a neutron is accompanied by an associated alpha-particle emitted in the opposite direction. A time and a direction of the neutron escape can be determined by measuring a time and coordinates of the alpha particle at the position-sensitive alpha-detector. The nanosecond tagged neutron technology (NTNT) based on this principle has great potentialities for various applications, e.g., for remote detection of explosives. A spectrum of gamma-rays emitted at the interaction of tagged neutrons with nuclei of chemical elements allows identify a chemical composition of an irradiated object. For practical realization of NTNT, a time resolution of recording the alpha-gamma coincidences should be close to 1 ns. The total intensity of signals can exceed 1 × 106 1/s from all gamma-detectors and 7 × 106 1/s from the alpha-detector. The processing of such stream of data without losses and distortion of information is one of challenging problems of NTNT. Several models of analog DAQ system based on hardware selection of events were devised and their characteristics are examined. The comparison with the digital DAQ systems demonstrated that the analog DAQ provides better timing parameters, lower power consumption, and higher maximum rate of useful events.
The Front-End System For MARE In Milano
NASA Astrophysics Data System (ADS)
Arnaboldi, Claudio; Pessina, Gianluigi
2009-12-01
The first phase of MARE consists of 72 μ-bolometers composed each of a crystal of AgReO4 readout by Si thermistors. The spread in the thermistor characteristics and bolometer thermal coupling leads to different energy conversion gains and optimum operating points of the detectors. Detector biasing levels and voltage gains are completely remote-adjustable by the front end system developed, the subject of this paper, achieving the same signal range at the input of the DAQ system. The front end consists of a cold buffer stage, a second pseudo differential stage followed by a gain stage, an antialiasing filter, and a battery powered detector biasing set up. The DAQ system can be used to set all necessary parameters of the electronics remotely, by writing to a μ-controller located on each board. Fiber optics are used for the serial communication between the DAQ and the front end. To suppress interference noise during normal operation, the clocked devices of the front end are maintained in sleep-mode, except during the set-up phase of the experiment. An automatic DC detector characterization procedure is used to establish the optimum operating point of every detector of the array. A very low noise level has been achieved: about 3nV/□Hz at 1 Hz and 1 nV/□Hz for the white component, high frequencies.
Electronics design of the RPC system for the OPERA muon spectrometer
NASA Astrophysics Data System (ADS)
Acquafredda, R.; Ambrosio, M.; Balsamo, E.; Barichello, G.; Bergnoli, A.; Consiglio, L.; Corradi, G.; dal Corso, F.; Felici, G.; Manea, C.; Masone, V.; Parascandolo, P.; Sorrentino, G.
2004-09-01
The present document describes the front-end electronics of the RPC system that instruments the magnet muon spectrometer of the OPERA experiment. The main task of the OPERA spectrometer is to provide particle tracking information for muon identification and simplify the matching between the Precision Trackers. As no trigger has been foreseen for the experiment, the spectrometer electronics must be self-triggered with single-plane readout capability. Moreover, precision time information must be added within each event frame for off-line reconstruction. The read-out electronics is made of three different stages: the Front-End Boards (FEBs) system, the Controller Boards (CBs) system and the Trigger Boards (TBs) system. The FEB system provides discrimination of the strip incoming signals; a FAST-OR output of the input signals is also available for trigger plane signal generation. FEB signals are acquired by the CB system that provides the zero suppression and manages the communication to the DAQ and Slow Control. A Trigger Board allows to operate in both self-trigger mode (the FEB's FAST-OR signal starts the plane acquisition) or in external-trigger mode (different conditions can be set on the FAST-OR signals generated from different planes).
Haddad, Mark; Menchetti, Marco; McKeown, Eamonn; Tylee, André; Mann, Anthony
2015-02-05
Depression is a common mental disorder associated with substantial disability. It is inadequately recognised and managed, and clinicians' attitudes to this condition and its treatment may play a part in this. Most research in this area has used the Depression Attitude Questionnaire (DAQ), but analyses have shown this measure to exhibit problems in psychometric properties and suitability for the health professionals and settings where depression recognition may occur. We revised the DAQ using a pooled review of findings from studies using this measure, together with a Delphi study which sought the opinions of a panel of relevant experts based in the UK, USA, Australia, and European countries (n = 24) using 3 rounds of questioning to consider attitude dimensions, content, and item wording. After item generation, revision and consensus (agreement >70%) using the Delphi panel, the revised DAQ (R-DAQ) was tested with 1193 health care providers to determine its psychometric properties. Finally the test-retest reliability of the R-DAQ was examined with 38 participants. The 22-item R-DAQ scale showed good internal consistency: Cronbach's alpha coefficient was 0.84; and satisfactory test-retest reliability: intraclass correlation coefficient was 0.62 (95% C.I. 0.37 to 0.78). Exploratory factor analysis favoured a three-factor structure (professional confidence, therapeutic optimism/pessimism, and a generalist perspective), which accounted for 45.3% of the variance. The R-DAQ provides a revised tool for examining clinicians' views and understanding of depression. It addresses important weaknesses in the original measure whilst retaining items and dimensions that appeared valid. This revised scale is likely to be useful in examining attitudes across the health professional workforce and beyond the confines of the UK, and may be valuable for the purpose of evaluating training that aims to address clinicians' attitudes to depression. It incorporates key dimensions of attitudes with a modest number of items making it applicable to use in busy clinical settings.
File-based data flow in the CMS Filter Farm
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Andronidis, A.; Bawej, T.; Behrens, U.; Branson, J.; Chaze, O.; Cittolin, S.; Darlea, G.-L.; Deldicque, C.; Dobson, M.; Dupont, A.; Erhan, S.; Gigi, D.; Glege, F.; Gomez-Ceballos, G.; Hegeman, J.; Holzner, A.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, R. K.; Morovic, S.; Nunez-Barranco-Fernandez, C.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Roberts, P.; Sakulin, H.; Schwick, C.; Stieger, B.; Sumorok, K.; Veverka, J.; Zaza, S.; Zejdl, P.
2015-12-01
During the LHC Long Shutdown 1, the CMS Data Acquisition system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and prepare the ground for future upgrades of the detector front-ends. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. This approach provides additional decoupling between the HLT algorithms and the input and output data flow. All the metadata needed for bookkeeping of the data flow and the HLT process lifetimes are also generated in the form of small “documents” using the JSON encoding, by either services in the flow of the HLT execution (for rates etc.) or watchdog processes. These “files” can remain memory-resident or be written to disk if they are to be used in another part of the system (e.g. for aggregation of output data). We discuss how this redesign improves the robustness and flexibility of the CMS DAQ and the performance of the system currently being commissioned for the LHC Run 2.
The upgraded HADES trigger and data acquisition system
NASA Astrophysics Data System (ADS)
Michel, J.; Böhmer, M.; Kajetanowicz, M.; Korcyl, G.; Maier, L.; Palka, M.; Stroth, J.; Tarantola, A.; Traxler, M.; Ugur, C.; Yurevich, S.
2011-12-01
The HADES experiment is a High Acceptance Di-Electron Spectrometer located at GSI in Darmstadt, Germany. Recently, its trigger and data acquisition system was upgraded. The main goal was to substantially increase the event rate capability by a factor of up to 20 to reach 100 kHz in light and 20 kHz in heavy ion reaction systems. The total data rate written to storage is about 400 MByte/s in peak. In this context, the complete read-out system was exchanged to FPGA-based platforms using optical communication. For data transport a general-purpose real-time network protocol was developed to meet the strong requirements of the system. In particular, trigger information has to reach all front-end modules with latencies of less than 5 μs through up to 10 intermediate hubs in a star-like network setup. Monitoring and slow control features as well as readout and trigger distribution were joined in a single network protocol made up by three virtual channels with inherent arbitration by priority and a typical switching time of 100 ns. The full DAQ system includes about 550 FPGAs distributed over the complete detector system. For control and monitoring a virtual address space spanning the whole network is provided. Data are merged by the network hubs into data streams and passed on to a server farm using an Ethernet infrastructure. Due to the electromagnetic noise environment, several transmission error detection and correction features were included. In collaboration with groups from experiments of the FAIR accelerator complex, further developments based on the versatile hardware and communication protocol are being pursued.
Achieving High Performance With TCP Over 40 GbE on NUMA Architectures for CMS Data Acquisition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bawej, Tomasz; et al.
2014-01-01
TCP and the socket abstraction have barely changed over the last two decades, but at the network layer there has been a giant leap from a few megabits to 100 gigabits in bandwidth. At the same time, CPU architectures have evolved into the multicore era and applications are expected to make full use of all available resources. Applications in the data acquisition domain based on the standard socket library running in a Non-Uniform Memory Access (NUMA) architecture are unable to reach full efficiency and scalability without the software being adequately aware about the IRQ (Interrupt Request), CPU and memory affinities.more » During the first long shutdown of LHC, the CMS DAQ system is going to be upgraded for operation from 2015 onwards and a new software component has been designed and developed in the CMS online framework for transferring data with sockets. This software attempts to wrap the low-level socket library to ease higher-level programming with an API based on an asynchronous event driven model similar to the DAT uDAPL API. It is an event-based application with NUMA optimizations, that allows for a high throughput of data across a large distributed system. This paper describes the architecture, the technologies involved and the performance measurements of the software in the context of the CMS distributed event building.« less
Design, modeling, simulation and evaluation of a distributed energy system
NASA Astrophysics Data System (ADS)
Cultura, Ambrosio B., II
This dissertation presents the design, modeling, simulation and evaluation of distributed energy resources (DER) consisting of photovoltaics (PV), wind turbines, batteries, a PEM fuel cell and supercapacitors. The distributed energy resources installed at UMass Lowell consist of the following: 2.5kW PV, 44kWhr lead acid batteries and 1500W, 500W & 300W wind turbines, which were installed before year 2000. Recently added to that are the following: 10.56 kW PV array, 2.4 kW wind turbine, 29 kWhr Lead acid batteries, a 1.2 kW PEM fuel cell and 4-140F supercapacitors. Each newly added energy resource has been designed, modeled, simulated and evaluated before its integration into the existing PV/Wind grid-connected system. The Mathematical and Simulink model of each system was derived and validated by comparing the simulated and experimental results. The Simulated results of energy generated from a 10.56kW PV system are in good agreement with the experimental results. A detailed electrical model of a 2.4kW wind turbine system equipped with a permanent magnet generator, diode rectifier, boost converter and inverter is presented. The analysis of the results demonstrates the effectiveness of the constructed simulink model, and can be used to predict the performance of the wind turbine. It was observed that a PEM fuel cell has a very fast response to load changes. Moreover, the model has validated the actual operation of the PEM fuel cell, showing that the simulated results in Matlab Simulink are consistent with the experimental results. The equivalent mathematical equation, derived from an electrical model of the supercapacitor, is used to simulate its voltage response. The model is completely capable of simulating its voltage behavior, and can predict the charge time and discharge time of voltages on the supercapacitor. The bi-directional dc-dc converter was designed in order to connect the 48V battery bank storage to the 24V battery bank storage. This connection was needed in order to increase the reliability of the DER system. Furthermore, the new computer-based Data Acquisition (DAQ) system for the DER has been designed and installed. The DAQ system is an important component in PC-based measurement, which is used in acquiring and storing data. The design and installation of signal conditioning improve the accuracy, effectiveness and safety of measurements, because of capabilities such as amplifications, isolation, and filtering. A Labview program was the software used to interface and communicate between the DAQ devices and the personal computer. The overall simulink model of the DER system is presented in the last chapter. The simulink model is discussed, and the discussion explains the operation of a grid connected DER. This model can be used as the basis or future reference for designs and installations of DER projects. This model can also be used in converting the DER grid connected system into a Smart Grid system, and that will be the next potential research work to explore.
The characterization and application of a low resource FPGA-based time to digital converter
NASA Astrophysics Data System (ADS)
Balla, Alessandro; Mario Beretta, Matteo; Ciambrone, Paolo; Gatta, Maurizio; Gonnella, Francesco; Iafolla, Lorenzo; Mascolo, Matteo; Messi, Roberto; Moricciani, Dario; Riondino, Domenico
2014-03-01
Time to Digital Converters (TDCs) are very common devices in particles physics experiments. A lot of "off-the-shelf" TDCs can be employed but the necessity of a custom DAta acQuisition (DAQ) system makes the TDCs implemented on the Field-Programmable Gate Arrays (FPGAs) desirable. Most of the architectures developed so far are based on the tapped delay lines with precision down to 10 ps, obtained with high FPGA resources usage and non-linearity issues to be managed. Often such precision is not necessary; in this case TDC architectures with low resources occupancy are preferable allowing the implementation of data processing systems and of other utilities on the same device. In order to reconstruct γγ physics events tagged with High Energy Tagger (HET) in the KLOE-2 (K LOng Experiment 2), we need to measure the Time Of Flight (TOF) of the electrons and positrons from the KLOE-2 Interaction Point (IP) to our tagging stations (11 m apart). The required resolution must be better than the bunch spacing (2.7 ns). We have developed and implemented on a Xilinx Virtex-5 FPGA a 32 channel TDC with a precision of 255 ps and low non-linearity effects along with an embedded data acquisition system and the interface to the online FARM of KLOE-2. The TDC is based on a low resources occupancy technique: the 4×Oversampling technique which, in this work, is pushed to its best resolution and its performances were exhaustively measured.
PCDAQ, A Windows Based DAQ System
NASA Astrophysics Data System (ADS)
Hogan, Gary
1998-10-01
PCDAQ is a Windows NT based general DAQ/Analysis/Monte Carlo shell developed as part of the Proton Radiography project at LANL (Los Alamos National Laboratory). It has been adopted by experiments outside of the Proton Radiography project at Brookhaven National Laboratory (BNL) and at LANL. The program provides DAQ, Monte Carlo, and replay (disk file input) modes. Data can be read from hardware (CAMAC) or other programs (ActiveX servers). Future versions will read VME. User supplied data analysis routines can be written in Fortran, C++, or Visual Basic. Histogramming, testing, and plotting packages are provided. Histogram data can be exported to spreadsheets or analyzed in user supplied programs. Plots can be copied and pasted as bitmap objects into other Windows programs or printed. A text database keyed by the run number is provided. Extensive software control flags are provided so that the user can control the flow of data through the program. Control flags can be set either in script command files or interactively. The program can be remotely controlled and data accessed over the Internet through its ActiveX DCOM interface.
NASA Astrophysics Data System (ADS)
Avolio, G.; Corso Radu, A.; Kazarov, A.; Lehmann Miotto, G.; Magnoni, L.
2012-12-01
The Trigger and Data Acquisition (TDAQ) system of the ATLAS experiment is a very complex distributed computing system, composed of more than 20000 applications running on more than 2000 computers. The TDAQ Controls system has to guarantee the smooth and synchronous operations of all the TDAQ components and has to provide the means to minimize the downtime of the system caused by runtime failures. During data taking runs, streams of information messages sent or published by running applications are the main sources of knowledge about correctness of running operations. The huge flow of operational monitoring data produced is constantly monitored by experts in order to detect problems or misbehaviours. Given the scale of the system and the rates of data to be analyzed, the automation of the system functionality in the areas of operational monitoring, system verification, error detection and recovery is a strong requirement. To accomplish its objective, the Controls system includes some high-level components which are based on advanced software technologies, namely the rule-based Expert System and the Complex Event Processing engines. The chosen techniques allow to formalize, store and reuse the knowledge of experts and thus to assist the shifters in the ATLAS control room during the data-taking activities.
Remote sensing from the desktop up, a students's personal stairway to space (Invited)
NASA Astrophysics Data System (ADS)
Church, W.
2013-12-01
Doing science with real-time quantitative experiments is becoming more and more affordable and accessible. Because lab equipment is more affordable and accessible, many universities are using lab class models wherein students conduct their experiments in informal settings such as the dorm, outside, or other places throughout the campus. Students are doing real-time measurements homework outside of class. By liberating experiments from facilities, the hope is to give students more experimental science opportunities. The challenge is support. In lab settings, instructors and peers can help students if they have trouble with the steps of assembling their experimental set-up, configuring the data acquisition software, conducting the real-time measurement and doing the analysis. Students working on their own in a dorm do not benefit from this support. Furthermore, when students are given the open ended experimental task of designing their own measurement system, they may need more guidance. In this poster presentation, I will articulate a triangle model to support students through the task of finding the necessary resources to design and build a mission to space. In the triangle model, students have access to base layer concept and skill resources to help them build their experiment. They then have access to middle layer mini-experiments to help them configure and test their experimental set-up. Finally, they have a motivating real-time experiment. As an example of this type of resource used in practice, I will have a balloon science remote sensing project as a stand-in for a balloon mission to 100,000 feet. I will use an Arduino based DAQ system and XBee modules for wireless data transmission to a LabVIEW front-panel. I will attach the DAQ to a tethered balloon to conduct a real-time microclimate experiment in the Moscone Center. Expanded microclimate studies can be the capstone project or can be a stepping-stone to space wherein students prepare a sensor package for a weather balloon launch to 100,000 feet.
NASA Astrophysics Data System (ADS)
Lee, J. K.; Shin, J.; Kim, K. H.; Jin, H.; Kim, H.; Kwon, J.; Lee, S.; Jee, G.; Lessard, M.
2016-12-01
A ground-based bi-axial search-coil magnetometer (SCM) has been devloped for observation of time-varying magnetic fields (dB/dt) in the Ultra Low Frequency (ULF) range (a few mHz up to 5 Hz) to understand magnetosphere-ionosphere coupling processes. The SCM consists of magnetic sensors, analog electronics, cables and data acquisition system (DAQ). The bi-axial magnetic sensor has coils of wire wound around a mu-metal cores, each of which measures magnetic field pulsations in the horizontal components, geomagnetic north-south and east-west, respectively. The analog electronics is designed to control the cut-off frequency of the instrument and to amplify detected signals. The DAQ has a 16 bit analog to digital converter (ADC) at the user defined rate of 10 Hz. It is also equipped with the Global Positioning System (GPS) and Network Time Protocol (NTP) for time synchronization and accuracy. We have carried out in-lab performance tests (e.g., frequency response, noise level, etc) using a magnetically shielded case and a field-test in a magnetically quiet location in South Korea. During the field test, a ULF Pi 2 event has been observed clearly. We also confirmed that it was a substorm activity from a fluxgate magnetometer data at Mineyama (35°57.3'N, 135°05'E, geographic). The SCM will be installed and operated at Jang Bogo Antarctic Research Station (74°37.4'S, 164°13.7'E, geographic) on Dec. 2016. The geomagnetic latitude of the station is similar to that of the US McMurdo station (77°51'S, 166°40'E, geographic), both of which are typically near the cusp region. Thus, we expect that the SCM can provide useful information to understand ULF wave propagation characteristics.
The DAQ needle in the big-data haystack
NASA Astrophysics Data System (ADS)
Meschi, E.
2015-12-01
In the last three decades, HEP experiments have faced the challenge of manipulating larger and larger masses of data from increasingly complex, heterogeneous detectors with millions and then tens of millions of electronic channels. LHC experiments abandoned the monolithic architectures of the nineties in favor of a distributed approach, leveraging the appearence of high speed switched networks developed for digital telecommunication and the internet, and the corresponding increase of memory bandwidth available in off-the-shelf consumer equipment. This led to a generation of experiments where custom electronics triggers, analysing coarser-granularity “fast” data, are confined to the first phase of selection, where predictable latency and real time processing for a modest initial rate reduction are “a necessary evil”. Ever more sophisticated algorithms are projected for use in HL- LHC upgrades, using tracker data in the low-level selection in high multiplicity environments, and requiring extremely complex data interconnects. These systems are quickly obsolete and inflexible but must nonetheless survive and be maintained across the extremely long life span of current detectors. New high-bandwidth bidirectional links could make high-speed low-power full readout at the crossing rate a possibility already in the next decade. At the same time, massively parallel and distributed analysis of unstructured data produced by loosely connected, “intelligent” sources has become ubiquitous in commercial applications, while the mass of persistent data produced by e.g. the LHC experiments has made multiple pass, systematic, end-to-end offline processing increasingly burdensome. A possible evolution of DAQ and trigger architectures could lead to detectors with extremely deep asynchronous or even virtual pipelines, where data streams from the various detector channels are analysed and indexed in situ quasi-real-time using intelligent, pattern-driven data organization, and the final selection is operated as a distributed “search for interesting event parts”. A holistic approach is required to study the potential impact of these different developments on the design of detector readout, trigger and data acquisition systems in the next decades.
NASA Astrophysics Data System (ADS)
Sherman, Justin; Azzari, Phillip; Crilly, P. B.; Duke-Tinson, Omar; James, Royce W.; Karama, Jackson; Page, E. J.; Schlank, Carter; Zuniga, Jonathan
2014-10-01
CGAPL is conducting small investigations in plasma physics and magneto-hydrodynamics buoy positioning. For data management, we are developing capability to analyze/digitize data with a National Instruments Data Acquisition board, 2 MS/s sampling rate (long time scale), and an Express Octopus card, 125 MS/s sampling rate (short scale). Sampling at 12 bits precision, we use LabVIEW as a programing language; GUIs will control variables in 1 or more concurrent runs and monitor of diagnostics. HPX utilizes high density (1013 cm3 up), low pressure (.01 T) Ar gas (fill pressure: on 104 mTorr order). Helicon/W Mode plasmas become a diagnostics test-bed for other investigations and a tool for future spacecraft propulsion devices. Plasmas created by directing energy into gas-filled Pyrex tube; power supply and matching box, up to 250 W power in 20-100 MHz frequencies, provide energy to ignite. Uniform magnetic field needed to reach the W-Mode. We employ an electromagnet to B-field while an acceleration coil positions plasma in vacuum chamber, facilitating analysis. Initial field requirements and accuracy calibration have been completed. Progress on development and implementation of probes and DAQ/GUI system will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY13.
NASA Astrophysics Data System (ADS)
Johnson, Bart; Atia, Walid; Kuznetsov, Mark; Cook, Christopher; Goldberg, Brian; Wells, Bill; Larson, Noble; McKenzie, Eric; Melendez, Carlos; Mallon, Ed; Woo, Seungbum; Murdza, Randal; Whitney, Peter; Flanders, Dale
A 1060 nm OEM laser "engine", manufactured by Axsun Technologies, is described. It consists of a swept laser and control electronics coupled with a balanced receiver, k-clock, and a 550 MS/s data acquisition board. The laser's passive mode-locking behavior induced by the rapid wavelength sweep is discussed. As they pass though the gain medium, each pulse is shifted to longer wavelength due to the rise in refractive index associated with gain depletion. New, longer wavelengths, are thus created by nonlinear means rather than by building up anew from spontaneous emission. This nonlinear mechanism enables low noise operation and fast sweep rates. The so-called "coherence revival" phenomenon associated with interference between neighboring mode-locked pulses, is discussed. Typical laser and system data is shown, including k-clock frequency, trigger waveform, pulsed and average output powers and RIN. Receiver and DAQ board noise performance is quantified. The laser RIN is estimated to be lower than -150 dB/Hz. A typical shot-noise-limited sensitivity of 103 dB is achieved for 1.9 mW sample power. The engine is designed for ophthalmic imaging and retinal images from prototype commercial systems are presented.
DAQ: Software Architecture for Data Acquisition in Sounding Rockets
NASA Technical Reports Server (NTRS)
Ahmad, Mohammad; Tran, Thanh; Nichols, Heidi; Bowles-Martinez, Jessica N.
2011-01-01
A multithreaded software application was developed by Jet Propulsion Lab (JPL) to collect a set of correlated imagery, Inertial Measurement Unit (IMU) and GPS data for a Wallops Flight Facility (WFF) sounding rocket flight. The data set will be used to advance Terrain Relative Navigation (TRN) technology algorithms being researched at JPL. This paper describes the software architecture and the tests used to meet the timing and data rate requirements for the software used to collect the dataset. Also discussed are the challenges of using commercial off the shelf (COTS) flight hardware and open source software. This includes multiple Camera Link (C-link) based cameras, a Pentium-M based computer, and Linux Fedora 11 operating system. Additionally, the paper talks about the history of the software architecture's usage in other JPL projects and its applicability for future missions, such as cubesats, UAVs, and research planes/balloons. Also talked about will be the human aspect of project especially JPL's Phaeton program and the results of the launch.
A Control System and Streaming DAQ Platform with Image-Based Trigger for X-ray Imaging
NASA Astrophysics Data System (ADS)
Stevanovic, Uros; Caselle, Michele; Cecilia, Angelica; Chilingaryan, Suren; Farago, Tomas; Gasilov, Sergey; Herth, Armin; Kopmann, Andreas; Vogelgesang, Matthias; Balzer, Matthias; Baumbach, Tilo; Weber, Marc
2015-06-01
High-speed X-ray imaging applications play a crucial role for non-destructive investigations of the dynamics in material science and biology. On-line data analysis is necessary for quality assurance and data-driven feedback, leading to a more efficient use of a beam time and increased data quality. In this article we present a smart camera platform with embedded Field Programmable Gate Array (FPGA) processing that is able to stream and process data continuously in real-time. The setup consists of a Complementary Metal-Oxide-Semiconductor (CMOS) sensor, an FPGA readout card, and a readout computer. It is seamlessly integrated in a new custom experiment control system called Concert that provides a more efficient way of operating a beamline by integrating device control, experiment process control, and data analysis. The potential of the embedded processing is demonstrated by implementing an image-based trigger. It records the temporal evolution of physical events with increased speed while maintaining the full field of view. The complete data acquisition system, with Concert and the smart camera platform was successfully integrated and used for fast X-ray imaging experiments at KIT's synchrotron radiation facility ANKA.
Gamma Ray Large Area Space Telescope (GLAST) Balloon Flight Engineering Model: Overview
NASA Technical Reports Server (NTRS)
Thompson, D. J.; Godfrey, G.; Williams, S. M.; Grove, J. E.; Mizuno, T.; Sadrozinski, H. F.-W.; Kamae, T.; Ampe, J.; Briber, Stuart; Dann, James;
2001-01-01
The Gamma Ray Large Area Space Telescope (GLAST) Large Area Telescope (LAT) is a pair-production high-energy (greater than 20 MeV) gamma-ray telescope being built by an international partnership of astrophysicists and particle physicists for a satellite launch in 2006, designed to study a wide variety of high-energy astrophysical phenomena. As part of the development effort, the collaboration has built a Balloon Flight Engineering Model (BFEM) for flight on a high-altitude scientific balloon. The BFEM is approximately the size of one of the 16 GLAST-LAT towers and contains all the components of the full instrument: plastic scintillator anticoincidence system (ACD), high-Z foil/Si strip pair-conversion tracker (TKR), CsI hodoscopic calorimeter (CAL), triggering and data acquisition electronics (DAQ), commanding system, power distribution, telemetry, real-time data display, and ground data processing system. The principal goal of the balloon flight was to demonstrate the performance of this instrument configuration under conditions similar to those expected in orbit. Results from a balloon flight from Palestine, Texas, on August 4, 2001, show that the BFEM successfully obtained gamma-ray data in this high-background environment.
NASA Astrophysics Data System (ADS)
James, R. W.; Chamberlin, A.; Azzari, P.; Crilly, P.; Emami, T.; Hopson, J.; Karama, J.; Green, A.; Paolino, R. N.; Sandri, E.; Turk, J.; Wicke, M.; Cgapl Team
2017-10-01
The small Helicon Plasma Experiment (HPX) at the Coast Guard Academy Plasma Lab (CGAPL), continues to progress toward utilizing the reputed high densities (1013 cm-3 and higher) at low pressure (.01 T) [1] of helicons, for eventual high temperature and density diagnostic development in future laboratory investigations. HPX is designed to create repeatedly stable plasmas ( 20-30 ns) induced by an RF frequency in the 10 to 70 MHz range. HPX has constructed a protected Langmuir probe where raw data will be collected, compared to the RF compensated probe and used to measure the plasma's density, temperature, and behavior during experiments. Our 2.5 J YAG laser Thomson Scattering system backed by a 32-channel Data Acquisition (DAQ) system is capable 12 bits of sampling precision at 2 MS/s for HPX plasma property investigations are being integrated into the existing diagnostics and control architecture. Progress on the construction of the RF coupling system, Helicon Mode development, and magnetic coils, along with observations from the Thomson Scattering, particle, and electromagnetic scattering diagnostics will be reported. Supported by U.S. DEPS Grant [HEL-JTO] PRWJFY17.
File-Based Data Flow in the CMS Filter Farm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, J.M.; et al.
2015-12-23
During the LHC Long Shutdown 1, the CMS Data Acquisition system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and prepare the ground for future upgrades of the detector front-ends. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. This approach provides additional decoupling between the HLT algorithms and the input and output data flow. All the metadata needed for bookkeeping of the data flow and the HLT process lifetimes aremore » also generated in the form of small “documents” using the JSON encoding, by either services in the flow of the HLT execution (for rates etc.) or watchdog processes. These “files” can remain memory-resident or be written to disk if they are to be used in another part of the system (e.g. for aggregation of output data). We discuss how this redesign improves the robustness and flexibility of the CMS DAQ and the performance of the system currently being commissioned for the LHC Run 2.« less
Comparison of Monte Carlo simulated and measured performance parameters of miniPET scanner
NASA Astrophysics Data System (ADS)
Kis, S. A.; Emri, M.; Opposits, G.; Bükki, T.; Valastyán, I.; Hegyesi, Gy.; Imrek, J.; Kalinka, G.; Molnár, J.; Novák, D.; Végh, J.; Kerek, A.; Trón, L.; Balkay, L.
2007-02-01
In vivo imaging of small laboratory animals is a valuable tool in the development of new drugs. For this purpose, miniPET, an easy to scale modular small animal PET camera has been developed at our institutes. The system has four modules, which makes it possible to rotate the whole detector system around the axis of the field of view. Data collection and image reconstruction are performed using a data acquisition (DAQ) module with Ethernet communication facility and a computer cluster of commercial PCs. Performance tests were carried out to determine system parameters, such as energy resolution, sensitivity and noise equivalent count rate. A modified GEANT4-based GATE Monte Carlo software package was used to simulate PET data analogous to those of the performance measurements. GATE was run on a Linux cluster of 10 processors (64 bit, Xeon with 3.0 GHz) and controlled by a SUN grid engine. The application of this special computer cluster reduced the time necessary for the simulations by an order of magnitude. The simulated energy spectra, maximum rate of true coincidences and sensitivity of the camera were in good agreement with the measured parameters.
The Trigger and Data Acquisition System for the KM3NeT neutrino telescope
NASA Astrophysics Data System (ADS)
Pellegrino, Carmelo; Chiarusi, Tommaso
2016-04-01
KM3NeT is a large research infrastructure in the Mediterranean Sea that includes a network of deep-sea neutrino telescopes. The telescopes consist of vertical detection units carrying optical modules, whose separation is optimised according to the different ranges of neutrino energy that shall be explored. Two building blocks, each one made of 115 detection units, will be deployed at the KM3NeT-IT site, about 80 km from Capo Passero, Italy, to search for high-energy neutrino sources (ARCA); another building block will be installed at the KM3NeT-Fr site, about 40 km from Toulon, France, to study the hierarchy of neutrino masses (ORCA). The modular design of the KM3NeT allows for a progressive implementation and data taking even with an incomplete detector. The same scalable design is used for the Trigger and Data Acquisition Systems (TriDAS). In order to reduce the complexity of the hardware inside the optical modules, the "all data to shore" concept is adopted. This implies that the throughput is dominated by the optical background due to the decay of 40K dissolved in the sea water and to the bursts of bioluminescence, about 3 orders of magnitude larger than the physics signal, ranging from 20 Gbps to several hundreds Gbps, according to the number of detection units. In addition, information from the acoustic positioning system of the detection units must be transmitted. As a consequence of the detector construction, the on-shore DAQ infrastructure must be expanded to handle an increasing data-rate and implement an efficient fast data filtering for both the optical and acoustic channels. In this contribution, the Trigger and Data Acquisition System designed for the Phase 1 of KM3NeT and its future expansion are presented. The network infrastructure, the shore computing resources and the developed applications for handling, filtering and monitoring the optical and acoustic data-streams are described.
Kuhn, Donald M; Francescutti-Verbeem, Dina M; Thomas, David M
2006-08-01
Methamphetamine (METH) intoxication leads to persistent damage of dopamine (DA) nerve endings of the striatum. Recently, we and others have suggested that the neurotoxicity associated with METH is mediated by extensive microglial activation. DA itself has been shown to play an obligatory role in METH neurotoxicity, possibly through the formation of quinone species. We show presently that DA-quinones (DAQ) cause a time-dependent activation of cultured microglial cells. Microarray analysis of the effects of DAQ on microglial gene expression revealed that 101 genes were significantly changed in expression, with 73 genes increasing and 28 genes decreasing in expression. Among those genes differentially regulated by DAQ were those often associated with neurotoxic conditions including inflammation, cytokines, chemokines, and prostaglandins. In addition, microglial genes associated with a neuronally protective phenotype were among those that were downregulated by DAQ. These results implicate DAQ as one species that could cause early activation of microglial cells in METH intoxication, manifested as an alteration in the expression of a broad biomarker panel of genes. These results also link oxidative stress, chemical alterations in DA to its quinone, and microglial activation as part of a cascade of glial-neuronal crosstalk that can amplify METH-induced neurotoxicity.
NASA Astrophysics Data System (ADS)
Soni, Jignesh; Yadav, Ratnakar; Gahlaut, A.; Bansal, G.; Singh, M. J.; Bandyopadhyay, M.; Parmar, K. G.; Pandya, K.; Chakraborty, A.
2011-09-01
Negative ion Experimental facility has been setup at IPR. The facility consists of a RF based negative ion source (ROBIN)—procured under a license agreement with IPP Garching, as a replica of BATMAN, presently operating in IPP, 100 kW 1 MHz RF generators and a set of low and high voltage power supplies, vacuum system and diagnostics. 35 keV 10A H- beam is expected from this setup. Automated successful operation of the system requires an advanced, rugged, time proven and flexible control system. Further the data generated in the experimental phase needs to be acquired, monitored and analyzed to verify and judge the system performance. In the present test bed, this is done using a combination of PLC based control system and a PXI based data acquisition system. The control system consists of three different Siemens PLC systems viz. (1) S-7 400 PLC as a Master Control, (2) S-7 300 PLC for Vacuum system control and (3) C-7 PLC for RF generator control. Master control PLC directly controls all the subsystems except the Vacuum system and RF generator. The Vacuum system and RF generator have their own dedicated PLCs (S-7 300 and C-7 respectively). Further, these two PLC systems work as a slave for the Master control PLC system. Communication between PLC S-7 400, S-7 300 and central control room computer is done through Industrial Ethernet (IE). Control program and GUI are developed in Siemens Step-7 PLC programming software and Wincc SCADA software, respectively. There are approximately 150 analog and 200 digital control and monitoring signals required to perform complete closed loop control of the system. Since the source floats at high potential (˜35 kV); a combination of galvanic and fiber optic isolation has been implemented. PXI based Data Acquisition system (DAS) is a combination of PXI RT (Real time) system, front end signal conditioning electronics, host system and DAQ program. All the acquisition signals coming from various sub-systems are connected and acquired by the PXI RT system, through only fiber optics link for signal conditioning, electrical isolation and better noise immunity. Real time and Host application programs are developed in LabVIEW and the data shall be stored with a facility of online display of selected parameters. Mathematical calculations and report generation will take place at the end of each beam shot. The paper describes in detail about the design approach, implementation strategy, program development, commissioning and operational test result of ROBIN through a data acquisition and control system.
Using an ARM Processor to boost data acquisition rates
NASA Astrophysics Data System (ADS)
Brown, Anthony; Seaquest Collaboration
2015-10-01
It has been proposed, Fermilab E-1067, to use the SeaQuest (E906/E1039/1037) dimuon spectrometer to do a search for the dark photon and dark Higgs. The concept is that it would run in a parasitic mode with only minor upgrades to the spectrometer. There are various requirements for the upgrades but one of them is to increase the DAQ rates and one minimal cost approach to do this will be discussed. The currently running SeaQuest (E906) experiment has modest rate requirements of around 1 kHz. Since the dark particle search would involve recording particles originating in the first magnet used as a beam dump, the data rate will be higher than recording events just from the target. Thus the DAQ rate capability will need to be increased to around 10 kHz. There exists a possible very low cost solution as the Academica Sinica designed TDCs contains an ARM processor that was not needed to meet the original SeaQuest (E906 needs). Since the 120 GeV beam from the Main Injector is delivered in a 4 second spill, once per minute and the ARM processor on the TDC has two dual-ported memory chips, these could be used to store data during each spill and then read the data out in the time between spills.
Development of 2D imaging of SXR plasma radiation by means of GEM detectors
NASA Astrophysics Data System (ADS)
Chernyshova, M.; Czarski, T.; Jabłoński, S.; Kowalska-Strzeciwilk, E.; Poźniak, K.; Kasprowicz, G.; Zabołotny, W.; Wojeński, A.; Byszuk, A.; Burza, M.; Juszczyk, B.; Zienkiewicz, P.
2014-11-01
Presented 2D gaseous detector system has been developed and designed to provide energy resolved fast dynamic plasma radiation imaging in the soft X-Ray region with 0.1 kHz exposure frequency for online, made in real time, data acquisition (DAQ) mode. The detection structure is based on triple Gas Electron Multiplier (GEM) amplification structure followed by the pixel readout electrode. The efficiency of detecting unit was adjusted for the radiation energy region of tungsten in high-temperature plasma, the main candidate for the plasma facing material for future thermonuclear reactors. Here we present preliminary laboratory results and detector parameters obtained for the developed system. The operational characteristics and conditions of the detector were designed to work in the X-Ray range of 2-17 keV. The detector linearity was checked using the fluorescence lines of different elements and was found to be sufficient for good photon energy reconstruction. Images of two sources through various screens were performed with an X-Ray laboratory source and 55Fe source showing a good imaging capability. Finally offline stream-handling data acquisition mode has been developed for the detecting system with timing down to the ADC sampling frequency rate (~13 ns), up to 2.5 MHz of exposure frequency, which could pave the way to invaluable physics information about plasma dynamics due to very good time resolving ability. Here we present results of studied spatial resolution and imaging properties of the detector for conditions of laboratory moderate counting rates and high gain.
The DAQ system for the AEḡIS experiment
NASA Astrophysics Data System (ADS)
Prelz, F.; Aghion, S.; Amsler, C.; Ariga, T.; Bonomi, G.; Brusa, R. S.; Caccia, M.; Caravita, R.; Castelli, F.; Cerchiari, G.; Comparat, D.; Consolati, G.; Demetrio, A.; Di Noto, L.; Doser, M.; Ereditato, A.; Evans, C.; Ferragut, R.; Fesel, J.; Fontana, A.; Gerber, S.; Giammarchi, M.; Gligorova, A.; Guatieri, F.; Haider, S.; Hinterberger, A.; Holmestad, H.; Kellerbauer, A.; Krasnický, D.; Lagomarsino, V.; Lansonneur, P.; Lebrun, P.; Malbrunot, C.; Mariazzi, S.; Matveev, V.; Mazzotta, Z.; Müller, S. R.; Nebbia, G.; Nedelec, P.; Oberthaler, M.; Pacifico, N.; Pagano, D.; Penasa, L.; Petracek, V.; Prevedelli, M.; Ravelli, L.; Rienaecker, B.; Robert, J.; Røhne, O. M.; Rotondi, A.; Sacerdoti, M.; Sandaker, H.; Santoro, R.; Scampoli, P.; Simon, M.; Smestad, L.; Sorrentino, F.; Testera, G.; Tietje, I. C.; Widmann, E.; Yzombard, P.; Zimmer, C.; Zmeskal, J.; Zurlo, N.
2017-10-01
In the sociology of small- to mid-sized (O(100) collaborators) experiments the issue of data collection and storage is sometimes felt as a residual problem for which well-established solutions are known. Still, the DAQ system can be one of the few forces that drive towards the integration of otherwise loosely coupled detector systems. As such it may be hard to complete with off-the-shelf components only. LabVIEW and ROOT are the (only) two software systems that were assumed to be familiar enough to all collaborators of the AEḡIS (AD6) experiment at CERN: working out of the GXML representation of LabVIEW Data types, a semantically equivalent representation as ROOT TTrees was developed for permanent storage and analysis. All data in the experiment is cast into this common format and can be produced and consumed on both systems and transferred over TCP and/or multicast over UDP for immediate sharing over the experiment LAN. We describe the setup that has been able to cater to all run data logging and long term monitoring needs of the AEḡIS experiment so far.
Online data handling and storage at the CMS experiment
NASA Astrophysics Data System (ADS)
Andre, J.-M.; Andronidis, A.; Behrens, U.; Branson, J.; Chaze, O.; Cittolin, S.; Darlea, G.-L.; Deldicque, C.; Demiragli, Z.; Dobson, M.; Dupont, A.; Erhan, S.; Gigi, D.; Glege, F.; Gómez-Ceballos, G.; Hegeman, J.; Holzner, A.; Jimenez-Estupiñán, R.; Masetti, L.; Meijers, F.; Meschi, E.; Mommsen, RK; Morovic, S.; Nuñez-Barranco-Fernández, C.; O'Dell, V.; Orsini, L.; Paus, C.; Petrucci, A.; Pieri, M.; Racz, A.; Roberts, P.; Sakulin, H.; Schwick, C.; Stieger, B.; Sumorok, K.; Veverka, J.; Zaza, S.; Zejdl, P.
2015-12-01
During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced by the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ∼62 sources produced with an aggregate rate of ∼2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.
Online Data Handling and Storage at the CMS Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andre, J. M.; et al.
2015-12-23
During the LHC Long Shutdown 1, the CMS Data Acquisition (DAQ) system underwent a partial redesign to replace obsolete network equipment, use more homogeneous switching technologies, and support new detector back-end electronics. The software and hardware infrastructure to provide input, execute the High Level Trigger (HLT) algorithms and deal with output data transport and storage has also been redesigned to be completely file- based. All the metadata needed for bookkeeping are stored in files as well, in the form of small documents using the JSON encoding. The Storage and Transfer System (STS) is responsible for aggregating these files produced bymore » the HLT, storing them temporarily and transferring them to the T0 facility at CERN for subsequent offline processing. The STS merger service aggregates the output files from the HLT from ~62 sources produced with an aggregate rate of ~2GB/s. An estimated bandwidth of 7GB/s in concurrent read/write mode is needed. Furthermore, the STS has to be able to store several days of continuous running, so an estimated of 250TB of total usable disk space is required. In this article we present the various technological and implementation choices of the three components of the STS: the distributed file system, the merger service and the transfer system.« less
The laser control of the muon g -2 experiment at Fermilab
Anastasi, A.; Anastasio, A.; Avino, S.; ...
2017-11-09
Here, we present that the Muon g-2 Experiment at Fermilab is expected to start data taking in 2017. It will measure the muon anomalous magnetic moment, a μ = (g μ-2)/2 to an unprecedented precision: the goal is 0.14 parts per million (ppm). The new experiment will require upgrades of detectors, electronics and data acquisition equipment to handle the much higher data volumes and slightly higher instantaneous rates. In particular, it will require a continuous monitoring and state-of-art calibration of the detectors, whose response may vary on both the millisecond and hour long timescale. The calibration system is composed ofmore » six laser sources and a light distribution system will provide short light pulses directly into each crystal (54) of the 24 calorimeters which measure energy and arrival time of the decay positrons. A Laser Control board will manage the interface between the experiment and the laser source, allowing the generation of light pulses according to specific needs including detector calibration, study of detector performance in running conditions, evaluation of DAQ performance. Here we present and discuss the main features of the Laser Control board.« less
The laser control of the muon g -2 experiment at Fermilab
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anastasi, A.; Anastasio, A.; Avino, S.
Here, we present that the Muon g-2 Experiment at Fermilab is expected to start data taking in 2017. It will measure the muon anomalous magnetic moment, a μ = (g μ-2)/2 to an unprecedented precision: the goal is 0.14 parts per million (ppm). The new experiment will require upgrades of detectors, electronics and data acquisition equipment to handle the much higher data volumes and slightly higher instantaneous rates. In particular, it will require a continuous monitoring and state-of-art calibration of the detectors, whose response may vary on both the millisecond and hour long timescale. The calibration system is composed ofmore » six laser sources and a light distribution system will provide short light pulses directly into each crystal (54) of the 24 calorimeters which measure energy and arrival time of the decay positrons. A Laser Control board will manage the interface between the experiment and the laser source, allowing the generation of light pulses according to specific needs including detector calibration, study of detector performance in running conditions, evaluation of DAQ performance. Here we present and discuss the main features of the Laser Control board.« less
The Austrian radiation monitoring network ARAD - best practice and added value
NASA Astrophysics Data System (ADS)
Olefs, Marc; Baumgartner, Dietmar; Obleitner, Friedrich; Bichler, Christoph; Foelsche, Ulrich; Pietsch, Helga; Rieder, Harald; Weihs, Philipp; Geyer, Florian; Haiden, Thomas; Schöner, Wolfgang
2016-04-01
The Austrian RADiation monitoring network (ARAD) has been established to advance the national climate monitoring and to support satellite retrieval, atmospheric modelling and solar energy techniques development. Measurements cover the downwelling solar and thermal infrared radiation using instruments according to Baseline Surface Radiation Network (BSRN) standards. A unique feature of ARAD is its vertical dimension of five stations, covering an air column between about 200 m a.s.l. (Vienna) and 3100 m a.s.l. (BSRN site Sonnblick). The contribution outlines the aims and scopes of ARAD, its measurement and calibration standards, methods, strategies and station locations. ARAD network operation uses innovative data processing for quality assurance and quality control, applying manual and automated control algorithms. A combined uncertainty estimate for the broadband shortwave radiation fluxes at all five ARAD stations indicates that accuracies range from 1.5 to 23 %. If a directional response error of the pyranometers and the temperature response of the instruments and the data acquisition system (DAQ) is corrected, this expanded uncertainty reduces to 1.4 to 5.2 %. Thus, for large signals (global: 1000 W m-2, diffuse: 500 W m-2) BSRN target accuracies are met or closely met for 70 % of valid measurements at the ARAD stations after this correction. For small signals (50 W m-2), the targets are not achieved as a result of uncertainties associated with the DAQ or the instrument sensitivities. Additional accuracy gains can be achieved in future by additional measurements and corrections. However, for the measurement of direct solar radiation improved instrument accuracy is needed. ARAD could serve as a powerful example for establishing state-of-the-art radiation monitoring at the national level with a multiple-purpose approach. Instrumentation, guidelines and tools (such as the data quality control) developed within ARAD are best practices which could be adopted in other regions, thus saving high development costs.
The Austrian radiation monitoring network ARAD - best practice and added value
NASA Astrophysics Data System (ADS)
Olefs, M.; Baumgartner, D. J.; Obleitner, F.; Bichler, C.; Foelsche, U.; Pietsch, H.; Rieder, H. E.; Weihs, P.; Geyer, F.; Haiden, T.; Schöner, W.
2015-10-01
The Austrian RADiation monitoring network (ARAD) has been established to advance the national climate monitoring and to support satellite retrieval, atmospheric modelling and solar energy techniques development. Measurements cover the downwelling solar and thermal infrared radiation using instruments according to Baseline Surface Radiation Network (BSRN) standards. A unique feature of ARAD is its vertical dimension of five stations, covering an air column between about 200 m a.s.l. (Vienna) and 3100 m a.s.l. (BSRN site Sonnblick). The paper outlines the aims and scopes of ARAD, its measurement and calibration standards, methods, strategies and station locations. ARAD network operation uses innovative data processing for quality assurance and quality control, applying manual and automated control algorithms. A combined uncertainty estimate for the broadband shortwave radiation fluxes at all five ARAD stations indicates that accuracies range from 1.5 to 23 %. If a directional response error of the pyranometers and the temperature response of the instruments and the data acquisition system (DAQ) is corrected, this expanded uncertainty reduces to 1.4 to 5.2 %. Thus, for large signals (global: 1000 W m-2, diffuse: 500 W m-2) BSRN target accuracies are met or closely met for 70 % of valid measurements at the ARAD stations after this correction. For small signals (50 W m-2), the targets are not achieved as a result of uncertainties associated with the DAQ or the instrument sensitivities. Additional accuracy gains can be achieved in future by additional measurements and corrections. However, for the measurement of direct solar radiation improved instrument accuracy is needed. ARAD could serve as a powerful example for establishing state-of-the-art radiation monitoring at the national level with a multiple-purpose approach. Instrumentation, guidelines and tools (such as the data quality control) developed within ARAD are best practices which could be adopted in other regions, thus saving high development costs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Young Jin
The PowerPoint presentation focused on research goals, specific information about the atomic magnetometer, response and resolution factors of the SERF magnetometer, FC+AM systems, tests of field transfer and resolution on FC, gradient cancellation, testing of AM performance, ideas for a multi-channel AM, including preliminary sensitivity testing, and a description of a 6 channel DAQ system. A few ideas for future work ended the presentation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-16
... DEPARTMENT OF THE INTERIOR Bureau of Safety and Environmental Enforcement [Docket ID BSEE-2013-0005; OMB Control Number 1014-0017: 134E1700D2 EEEE500000 ET1SF0000.DAQ000] Information Collection Activities: Safety and Environmental Management Systems (SEMS); Proposed Collection; Comment Request Correction In notice document 2013-19416 appearing o...
Li, Xiaoli; Liu, Xiaomin
2014-01-01
In the last two decades, functional near-infrared spectroscopy (fNIRS) is getting more and more popular as a neuroimaging technique. The fNIRS instrument can be used to measure local hemodynamic response, which indirectly reflects the functional neural activities in human brain. In this study, an easily implemented way to establish DAQ-device-based fNIRS system was proposed. Basic instrumentation components (light sources driving, signal conditioning, sensors, and optical fiber) of the fNIRS system were described. The digital in-phase and quadrature demodulation method was applied in LabVIEW software to distinguish light sources from different emitters. The effectiveness of the custom-made system was verified by simultaneous measurement with a commercial instrument ETG-4000 during Valsalva maneuver experiment. The light intensity data acquired from two systems were highly correlated for lower wavelength (Pearson's correlation coefficient r = 0.92, P < 0.01) and higher wavelength (r = 0.84, P < 0.01). Further, another mental arithmetic experiment was implemented to detect neural activation in the prefrontal cortex. For 9 participants, significant cerebral activation was detected in 6 subjects (P < 0.05) for oxyhemoglobin and in 8 subjects (P < 0.01) for deoxyhemoglobin. PMID:25180044
2015-06-01
National Instruments. The National Instruments DAQ is a full-featured PC running Windows 7. The DAQ, electromagnetic transmitter , and batteries for the... electromagnetic induction Environet Environet, Inc. ESTCP Environmental Security Technology Certification Program ftp file transfer protocol FUDS formerly used...capabilities of a currently available advanced electromagnetic induction sensor developed specifically for discrimination on real sites under operational
Androphy, Elliot J.; Calo, Alessandro; Potter, Kyle; Custer, Sara K.; Du, Sarah; Foley, Timothy L.; Gopalsamy, Ariamala; Reedich, Emily J.; Gordo, Susana M.; Gordon, William; Hosea, Natalie; Jones, Lyn H.; Krizay, Daniel K.; LaRosa, Gregory; Li, Hongxia; Mathur, Sachin; Menard, Carol A.; Patel, Paraj; Ramos-Zayas, Rebeca; Rietz, Anne; Rong, Haojing; Zhang, Baohong; Tones, Michael A.
2017-01-01
C5-substituted 2,4-diaminoquinazoline inhibitors of the decapping scavenger enzyme DcpS (DAQ-DcpSi) have been developed for the treatment of spinal muscular atrophy (SMA), which is caused by genetic deficiency in the Survival Motor Neuron (SMN) protein. These compounds are claimed to act as SMN2 transcriptional activators but data underlying that claim are equivocal. In addition it is unclear whether the claimed effects on SMN2 are a direct consequence of DcpS inhibitor or might be a consequence of lysosomotropism, which is known to be neuroprotective. DAQ-DcpSi effects were characterized in cells in vitro utilizing DcpS knockdown and 7-methyl analogues as probes for DcpS vs non-DcpS-mediated effects. We also performed analysis of Smn transcript levels, RNA-Seq analysis of the transcriptome and SMN protein in order to identify affected pathways underlying the therapeutic effect, and studied lysosomotropic and non-lysosomotropic DAQ-DCpSi effects in 2B/- SMA mice. Treatment of cells caused modest and transient SMN2 mRNA increases with either no change or a decrease in SMNΔ7 and no change in SMN1 transcripts or SMN protein. RNA-Seq analysis of DAQ-DcpSi-treated N2a cells revealed significant changes in expression (both up and down) of approximately 2,000 genes across a broad range of pathways. Treatment of 2B/- SMA mice with both lysomotropic and non-lysosomotropic DAQ-DcpSi compounds had similar effects on disease phenotype indicating that the therapeutic mechanism of action is not a consequence of lysosomotropism. In striking contrast to the findings in vitro, Smn transcripts were robustly changed in tissues but there was no increase in SMN protein levels in spinal cord. We conclude that DAQ-DcpSi have reproducible benefit in SMA mice and a broad spectrum of biological effects in vitro and in vivo, but these are complex, context specific, and not the result of simple SMN2 transcriptional activation. PMID:28945765
Antioxidant intake and bone status in a cross-sectional study of Brazilian women with osteoporosis.
De França, Natasha A G; Camargo, Marilia B R; Lazaretti-Castro, Marise; Martini, Lígia Araújo
2013-04-01
This study aimed to investigate the association between antioxidant intake and bone mineral density (BMD) in postmenopausal women with osteoporosis. We conducted a cross-sectional study with 150 women, mean age 68.7 (SD 9.1) years. BMD and body composition were obtained using dual-energy X-ray absorptiometry (DXA). We assessed anthropometric measures and dietary intake and applied an adapted Dietary Antioxidant Quality Score (a-DAQS) to evaluate the antioxidant consumption. 65.3% of women had higher scores on the a-DAQS. We found no relationship between the a-DAQS and BMD; however, we observed an inverse correlation between vitamin A and lumbar spine (LS) BMD in g/cm(2) (r = - 0.201; p = 0.013). An analysis of variance (ANOVA) test also showed that vitamin A was negatively associated with the LS BMD (F = 6.143; p = 0.013, but without significance when a multivariate analysis was applied. The a-DAQS did not have an association with BMD; however, Vitamin A showed a negative correlation with BMD, but such an association disappeared when the other antioxidants were taken together. Our findings encourage an antioxidant-based dietary approach to osteoporosis prevention and treatment, since the negative effect of vitamin A was neutralized by the intake of such nutrients. © The Author(s) 2015.
Killer whale caller localization using a hydrophone array in an oceanarium pool
NASA Astrophysics Data System (ADS)
Bowles, Ann E.; Greenlaw, Charles F.; McGehee, Duncan E.; van Holliday, D.
2004-05-01
A system to localize calling killer whales was designed around a ten-hydrophone array in a pool at SeaWorld San Diego. The array consisted of nine ITC 8212 and one ITC 6050H hydrophones mounted in recessed 30×30 cm2 niches. Eight of the hydrophones were connected to a Compaq Armada E500 laptop computer through a National Instruments DAQ 6024E PCMCIA A/D data acquisition card and a BNC-2120 signal conditioner. The system was calibrated with a 139-dB, 4.5-kHz pinger. Acoustic data were collected during four 48-72 h recording sessions, simultaneously with video recorded from a four-camera array. Calling whales were localized by one of two methods, (1) at the hydrophone reporting the highest sound exposure level and (2) using custom-designed 3-D localization software based on time-of-arrival (ORCA). Complex reverberations in the niches and pool made locations based on time of arrival difficult to collect. Based on preliminary analysis of data from four sessions (400+ calls/session), the hydrophone reporting the highest level reliably attributed callers 51%-100% of the time. This represents a substantial improvement over attribution rates of 5%-15% obtained with single hydrophone recordings. [Funding provided by Hubbs-SeaWorld Research Institute and the Hubbs Society.
Muon data from a water Cherenkov detector prototype at Colorado State University
NASA Astrophysics Data System (ADS)
Longo, Megan; Mostafa, Miguel
2013-04-01
The High Altitude Water Cherenkov (HAWC) Observatory is a very high energy gamma-ray experiment currently under construction in Sierra Negra in the state of Puebla, Mexico, at an altitude of 4,100 m a.s.l. The HAWC Observatory will consist of 300 water Cherenkov detectors (WCDs), each instrumented with three 8'' photomultiplier tubes (PMTs) and one 10'' high efficiency (HE) PMT. The PMTs are upward facing, anchored to the bottom of a 5 m deep by 7.3 m diameter steel tank, containing a multilayer hermetic plastic bag holding 200,000 L of purified water. The only full size WCD prototype outside of the HAWC site is located at Colorado State University (CSU) in Fort Collins, CO at an altitude of 1,525 m a.s.l. This prototype is instrumented with six 8'' PMTs, one 10'' HE PMT, and the same laser calibration system, electronics, and data acquisition system as the WCDs at the HAWC site. The CSU prototype is additionally equipped with scintillator paddles both under and above the volume of water, temperature probes (in the water, outside, and in the DAQ room), and one covered PMT. Preliminary results for muon rates and their temperature dependance using data collected with the CSU prototype will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heffner, M.; Riot, V.; Fabris, L.
Medium to large channel count detectors are usually faced with a few unattractive options for data acquisition (DAQ). Small to medium sized TPC experiments, for example, can be too small to justify the high expense and long development time of application specific integrated circuit (ASIC) development. In some cases an experiment can piggy-back on a larger experiment and the associated ASIC development, but this puts the time line of development out of the hands of the smaller experiment. Another option is to run perhaps thousands of cables to rack mounted equipment, which is clearly undesirable. The development of commercial high-speedmore » high-density FPGAs and ADCs combined with the small discrete components and robotic assembly open a new option that scales to tens of thousands of channels and is only slightly larger than ASICs using off-the-shelf components.« less
NASA Astrophysics Data System (ADS)
2012-01-01
WE RECOMMEND Air swimmers Helium balloon swims like a fish Their Arrows will Darken the Sun: The Evolution and Science of Ballistics Ballistics book hits the spot Physics Experiments for your Bag Handy experiments for your lessons Quantum Physics for Poets Book shows the economic importance of physics SEP colour wheel kit Wheels investigate colour theory SEP colour mixing kit Cheap colour mixing kit uses red, green and blue LEDs iHandy Level iPhone app superbly measures angles Photonics Explorer kit Free optics kit given to schools WORTH A LOOK DrDAQ DrDAQ software gets an upgrade WEB WATCH Websites show range of physics
NASA Astrophysics Data System (ADS)
Ren, Zhong; Liu, Guodong; Zeng, Lvming; Huang, Zhen; Zeng, Wenping
2010-10-01
The tongue coating diagnosis is an important part in tongue diagnosis of traditional Chinese medicine (TCM).The change of the thickness and color of the tongue coating can reflect the pathological state for the patient. By observing the tongue coating, a Chinese doctor can determine the nature or severity of disease. Because some limitations existed in the tongue diagnosis method of TCM and the method based on the digital image processing, a novel tongue coating analyzer(TCA) based on the concave grating monochrometer and virtual instrument is developed in this paper. This analyzer consists of the light source system, check cavity, optical fiber probe, concave grating monochrometer, spectrum detector system based on CCD and data acquisition (DAQ) card, signal processing circuit system, computer and data analysis software based on LabVIEW, etc. Experimental results show that the novel TCA's spectral range can reach 300-1000 nm, its wavelength resolution can reach 1nm, and this TCA uses the back-split-light technology and multi-channel parallel analysis. Compared with the TCA based on the image processing technology, this TCA has many advantages, such as, compact volume, simpler algorithm, faster processing speed, higher accuracy, cheaper cost and real-time handle data and display the result, etc. Therefore, it has the greatly potential values in the fields of the tongue coating diagnosis for TCM.
NASA Technical Reports Server (NTRS)
Mangieri, Mark
2005-01-01
ARED flight instrumentation software is associated with an overall custom designed resistive exercise system that will be deployed on the International Space Station (ISS). This innovative software application fuses together many diverse and new technologies into a robust and usable package. The software takes advantage of touchscreen user interface technology by providing a graphical user interface on a Windows based tablet PC, meeting a design constraint of keyboard-less interaction with flight crewmembers. The software interacts with modified commercial data acquisition (DAQ) hardware to acquire multiple channels of sensor measurment from the ARED device. This information is recorded on the tablet PC and made available, via International Space Station (ISS) Wireless LAN (WLAN) and telemetry subsystems, to ground based mission medics and trainers for analysis. The software includes a feature to accept electronically encoded prescriptions of exercises that guide crewmembers through a customized regimen of resistive weight training, based on personal analysis. These electronically encoded prescriptions are provided to the crew via ISS WLAN and telemetry subsystems. All personal data is securely associated with an individual crew member, based on a PIN ID mechanism.
Haddad, Mark; Waqas, Ahmed; Sukhera, Ahmed Bashir; Tarar, Asad Zaman
2017-07-27
Depression is common mental health problem and leading contributor to the global burden of disease. The attitudes and beliefs of the public and of health professionals influence social acceptance and affect the esteem and help-seeking of people experiencing mental health problems. The attitudes of clinicians are particularly relevant to their role in accurately recognising and providing appropriate support and management of depression. This study examines the characteristics of the revised depression attitude questionnaire (R-DAQ) with doctors working in healthcare settings in Lahore, Pakistan. A cross-sectional survey was conducted in 2015 using the revised depression attitude questionnaire (R-DAQ). A convenience sample of 700 medical practitioners based in six hospitals in Lahore was approached to participate in the survey. The R-DAQ structure was examined using Parallel Analysis from polychoric correlations. Unweighted least squares analysis (ULSA) was used for factor extraction. Model fit was estimated using goodness-of-fit indices and the root mean square of standardized residuals (RMSR), and internal consistency reliability for the overall scale and subscales was assessed using reliability estimates based on Mislevy and Bock (BILOG 3 Item analysis and test scoring with binary logistic models. Mooresville: Scientific Software, 55) and the McDonald's Omega statistic. Findings using this approach were compared with principal axis factor analysis based on Pearson correlation matrix. 601 (86%) of the doctors approached consented to participate in the study. Exploratory factor analysis of R-DAQ scale responses demonstrated the same 3-factor structure as in the UK development study, though analyses indicated removal of 7 of the 22 items because of weak loading or poor model fit. The 3 factor solution accounted for 49.8% of the common variance. Scale reliability and internal consistency were adequate: total scale standardised alpha was 0.694; subscale reliability for professional confidence was 0.732, therapeutic optimism/pessimism was 0.638, and generalist perspective was 0.769. The R-DAQ was developed with a predominantly UK-based sample of health professionals. This study indicates that this scale functions adequately and provides a valid measure of depression attitudes for medical practitioners in Pakistan, with the same factor structure as in the scale development sample. However, optimal scale function necessitated removal of several items, with a 15-item scale enabling the most parsimonious factor solution for this population.
A new ATLAS muon CSC readout system with system on chip technology on ATCA platform
Claus, R.
2015-10-23
The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQmore » building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.« less
Ready to use detector modules for the NEAT spectrometer: Concept, design, first results
NASA Astrophysics Data System (ADS)
Magi, Ádám; Harmat, Péter; Russina, Margarita; Günther, Gerrit; Mezei, Ferenc
2018-05-01
The paper presents the detector system developed by Datalist Systems, Ltd. (previously ANTE Innovative Technologies) for the NEAT-II spectrometer at HZB. We present initial concept, design and implementation highlights as well as the first results of measurements such as position resolution. The initial concept called for modular architecture with 416 3He detector tubes organized into thirteen 32-tube modules that can be independently installed and removed to and from the detector vacuum chamber for ease of maintenance. The unalloyed aluminum mechanical support modules for four 8-tube units each also house the air-boxes that contain the front-end electronics (preamplifiers) that need to be on atmospheric pressure. The modules have been manufactured and partly assembled in Hungary and then fully assembled and installed on site by Datalist Systems crew. The signal processing and data acquisition solution is based on low time constant (˜60 ns) preamplifier electronics and sampling ADC's running at 50 MS/s (i.e. a sample every 20 ns) for all 832 data channels. The preamplifiers are proprietary, developed specifically for the NEAT spectrometer, while the ADC's and the FPGA's that further process the data are based on National Instruments products. The data acquisition system comprises 26 FPGA modules each serving 16 tubes (providing for up to 50 kHz count rate per individual tube) and it is organized into two PXI chassis and two data acquisition computers that perform post-processing, event classification and provide appropriate preview of the collected data. The data acquisition software based on Event Recording principles provides a single point of contact for the scientific software with an Event Record List with absolute timestamps of 100ns resolution, timing data of 100 ns resolution for the seven discs chopper system as well as classification data that can be used for flexible data filtering in off-line analysis of the gathered data. A unique 3-tier system of filtering criteria of events is in operation: a hard threshold in the FPGA's to reduce the effect of noise, a pulse-shape based classification to eliminate gamma sensitivity and an additional flexible feature based classification to filter out pileup and other unwanted phenomena. This ensures high count rates (50kHz per tube, 1MHz overall) while maintaining good quality of measurements (e.g. position resolution). The first measurement results show that the delivered detector system meets the initial requirements of 20 mm position resolution along the 2000mm long detector tubes. This is partly due to the innovative event classification system that provides vital pulse shape data that can be used for sophisticated position resolution algorithms implemented on the DAQ computers.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Santos, Bruno; Carvalho, Paulo F.; Rodrigues, A.P.
The ATCA standard specifies a mandatory Shelf Manager (ShM) unit which is a key element for the system operation. It includes the Intelligent Platform Management Controller (IPMC) which monitors the system health, retrieves inventory information and controls the Field Replaceable Units (FRUs). These elements enable the intelligent health monitoring, providing high-availability and safety operation, ensuring the correct system operation. For critical systems like ones of tokamak ITER these features are mandatory to support the long pulse operation. The Nominal Device Support (NDS) was designed and developed for the ITER CODAC Core System (CCS), which will be the responsible for plantmore » Instrumentation and Control (I and C), supervising and monitoring on ITER. It generalizes the Enhanced Physics and Industrial Control System (EPICS) device support interface for Data Acquisition (DAQ) and timing devices. However the support for health management features and ATCA ShM are not yet provided. This paper presents the implementation and test of a NDS for the ATCA ShM, using the ITER Fast Plant System Controller (FPSC) prototype environment. This prototype is fully compatible with the ITER CCS and uses the EPICS Channel Access (CA) protocol as the interface with the Plant Operation Network (PON). The implemented solution running in an EPICS Input / Output Controller (IOC) provides Process Variables (PV) to the PON network with the system information. These PVs can be used for control and monitoring by all CA clients, such as EPICS user interface clients and alarm systems. The results are presented, demonstrating the fully integration and the usability of this solution. (authors)« less
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity measurements with 3He alternative: Straw neutron detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mukhopadhyay, Sanjoy; Wolff, Ronald; Detwiler, Ryan
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as ‘‘ship effect ’’) and to the complicated nature of the neutron scattering in that environment. A prototype neutron detector was built using 10B as the converter in a special form factor called ‘‘straws’’ that would address the above problems by looking into the details of multiplicity distributions of neutrons originatingmore » from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylenemoderator. In the following year, we developed the field-programmable gate array and associated DAQ software. This SDRD effort successfully produced a prototype NMC with*33% detection efficiency compared to a commercial fission meter.« less
Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors
Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; ...
2015-01-27
Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B 4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect neutron multiplicity information from spontaneous fission sources using a single panel consisting of 60 straws equally distributed over three rows in high-density polyethylene moderator. In the following year, we developed the field-programmable gate array and associated DAQ software. Finally, this SDRD effort successfully produced a prototype NMC with ~33% detection efficiency compared to a commercial fission meter.« less
Development of a prototype sensor system for ultra-high-speed LDA-PIV
NASA Astrophysics Data System (ADS)
Griffiths, Jennifer A.; Royle, Gary J.; Bohndiek, Sarah E.; Turchetta, Renato; Chen, Daoyi
2008-04-01
Laser Doppler Anemometry (LDA) and Particle Image Velocimetry (PIV) are commonly used in the analysis of particulates in fluid flows. Despite the successes of these techniques, current instrumentation has placed limitations on the size and shape of the particles undergoing measurement, thus restricting the available data for the many industrial processes now utilising nano/micro particles. Data for spherical and irregularly shaped particles down to the order of 0.1 µm is now urgently required. Therefore, an ultra-fast LDA-PIV system is being constructed for the acquisition of this data. A key component of this instrument is the PIV optical detection system. Both the size and speed of the particles under investigation place challenging constraints on the system specifications: magnification is required within the system in order to visualise particles of the size of interest, but this restricts the corresponding field of view in a linearly inverse manner. Thus, for several images of a single particle in a fast fluid flow to be obtained, the image capture rate and sensitivity of the system must be sufficiently high. In order to fulfil the instrumentation criteria, the optical detection system chosen is a high-speed, lensed, digital imaging system based on state-of-the-art CMOS technology - the 'Vanilla' sensor developed by the UK based MI3 consortium. This novel Active Pixel Sensor is capable of high frame rates and sparse readout. When coupled with an image intensifier, it will have single photon detection capabilities. An FPGA based DAQ will allow real-time operation with minimal data transfer.
An EUDET/AIDA Pixel Beam Telescope for Detector Development
NASA Astrophysics Data System (ADS)
Rubinskiy, I.; EUDET Consortium; AIDA Consortium
Ahigh resolution(σ< 2 μm) beam telescope based on monolithic active pixel sensors (MAPS) was developed within the EUDET collaboration. EUDET was a coordinated detector R&D programme for the future International Linear Collider providing test beam infrastructure to detector R&D groups. The telescope consists of six sensor planes with a pixel pitch of either 18.4 μm or 10 μmand canbe operated insidea solenoidal magnetic fieldofupto1.2T.Ageneral purpose cooling, positioning, data acquisition (DAQ) and offine data analysis tools are available for the users. The excellent resolution, readout rate andDAQintegration capabilities made the telescopea primary beam tests tool also for several CERN based experiments. In this report the performance of the final telescope is presented. The plans for an even more flexible telescope with three differentpixel technologies(ATLASPixel, Mimosa,Timepix) withinthenew European detector infrastructure project AIDA are presented.
A Noncontact FMCW Radar Sensor for Displacement Measurement in Structural Health Monitoring
Li, Cunlong; Chen, Weimin; Liu, Gang; Yan, Rong; Xu, Hengyi; Qi, Yi
2015-01-01
This paper investigates the Frequency Modulation Continuous Wave (FMCW) radar sensor for multi-target displacement measurement in Structural Health Monitoring (SHM). The principle of three-dimensional (3-D) displacement measurement of civil infrastructures is analyzed. The requirements of high-accuracy displacement and multi-target identification for the measuring sensors are discussed. The fundamental measuring principle of FMCW radar is presented with rigorous mathematical formulas, and further the multiple-target displacement measurement is analyzed and simulated. In addition, a FMCW radar prototype is designed and fabricated based on an off-the-shelf radar frontend and data acquisition (DAQ) card, and the displacement error induced by phase asynchronism is analyzed. The conducted outdoor experiments verify the feasibility of this sensing method applied to multi-target displacement measurement, and experimental results show that three targets located at different distances can be distinguished simultaneously with millimeter level accuracy. PMID:25822139
A noncontact FMCW radar sensor for displacement measurement in structural health monitoring.
Li, Cunlong; Chen, Weimin; Liu, Gang; Yan, Rong; Xu, Hengyi; Qi, Yi
2015-03-26
This paper investigates the Frequency Modulation Continuous Wave (FMCW) radar sensor for multi-target displacement measurement in Structural Health Monitoring (SHM). The principle of three-dimensional (3-D) displacement measurement of civil infrastructures is analyzed. The requirements of high-accuracy displacement and multi-target identification for the measuring sensors are discussed. The fundamental measuring principle of FMCW radar is presented with rigorous mathematical formulas, and further the multiple-target displacement measurement is analyzed and simulated. In addition, a FMCW radar prototype is designed and fabricated based on an off-the-shelf radar frontend and data acquisition (DAQ) card, and the displacement error induced by phase asynchronism is analyzed. The conducted outdoor experiments verify the feasibility of this sensing method applied to multi-target displacement measurement, and experimental results show that three targets located at different distances can be distinguished simultaneously with millimeter level accuracy.
Mie Lidar for Aerosols and Clouds Monitoring at Otlica Observatory
NASA Astrophysics Data System (ADS)
Gao, F.; Stanič, S.; Bergant, K.; Filipčič, A.; Veberič, D.; Forte, B.
2009-04-01
Aerosol and cloud densities are the most important atmospheric parameters, which significantly influence the atmospheric conditions. The study of their spatial and temporal properties can provide detailed information about the transport processes of the air masses. In recent years, lidar techniques for remote sensing of the atmospheric parameters have been greatly improved. Like the lidar systems of the Pierre Auger Observatory in Argentina (35.2S, 69.1W, 1400 m a.s.l.), the Mie lidar built at Otlica Observatory (45.93N, 13.91E, 945 m a.s.l.) in Slovenia employs the same hardware, including the transmitter, the receiver, and the DAQ system. Due to its high-power laser, large-diameter telescope, and photon-counting data-acquisition technique, the Mie lidar has the potential ability to measure the tropospheric and stratospheric atmospheric conditions, and is suitable for monitoring the changes of the cirrus clouds and atmospheric boundary layer. We have been performing routine atmospheric monitoring experiments with the Otlica Mie lidar since September 2008. Using the techniques of event-averaging, noise-elimination, and data-gluing, the far end of lidar probing range is extended from 30 km up to 40 km. The extinction profiles are calculated using the Klett method and the time-height-intensity plots were made. They clearly show the evolution of atmospheric conditions, especially the motion of the cirrus clouds above Otlica.
Trigger design for a gamma ray detector of HIRFL-ETF
NASA Astrophysics Data System (ADS)
Du, Zhong-Wei; Su, Hong; Qian, Yi; Kong, Jie
2013-10-01
The Gamma Ray Array Detector (GRAD) is one subsystem of HIRFL-ETF (the External Target Facility (ETF) of the Heavy Ion Research Facility in Lanzhou (HIRFL)). It is capable of measuring the energy of gamma-rays with 1024 CsI scintillators in in-beam nuclear experiments. The GRAD trigger should select the valid events and reject the data from the scintillators which are not hit by the gamma-ray. The GRAD trigger has been developed based on the Field Programmable Gate Array (FPGAs) and PXI interface. It makes prompt trigger decisions to select valid events by processing the hit signals from the 1024 CsI scintillators. According to the physical requirements, the GRAD trigger module supplies 12-bit trigger information for the global trigger system of ETF and supplies a trigger signal for data acquisition (DAQ) system of GRAD. In addition, the GRAD trigger generates trigger data that are packed and transmitted to the host computer via PXI bus to be saved for off-line analysis. The trigger processing is implemented in the front-end electronics of GRAD and one FPGA of the GRAD trigger module. The logic of PXI transmission and reconfiguration is implemented in another FPGA of the GRAD trigger module. During the gamma-ray experiments, the GRAD trigger performs reliably and efficiently. The function of GRAD trigger is capable of satisfying the physical requirements.
Beam Stability R&D for the APS MBA Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sereno, Nicholas S.; Arnold, Ned D.; Bui, Hanh D.
2015-01-01
Beam diagnostics required for the APS Multi-bend acromat (MBA) are driven by ambitious beam stability requirements. The major AC stability challenge is to correct rms beam motion to 10% the rms beam size at the insertion device source points from0.01 to 1000 Hz. The vertical plane represents the biggest challenge forAC stability, which is required to be 400 nm rms for a 4-micron vertical beam size. In addition to AC stability, long-term drift over a period of seven days is required to be 1 micron or less. Major diagnostics R&D components include improved rf beam position processing using commercially availablemore » FPGA-based BPM processors, new X-ray beam position monitors based on hard X-ray fluorescence from copper and Compton scattering off diamond, mechanical motion sensing to detect and correct long-term vacuum chamber drift, a new feedback system featuring a tenfold increase in sampling rate, and a several-fold increase in the number of fast correctors and BPMs in the feedback algorithm. Feedback system development represents a major effort, and we are pursuing development of a novel algorithm that integrates orbit correction for both slow and fast correctors down to DC simultaneously. Finally, a new data acquisition system (DAQ) is being developed to simultaneously acquire streaming data from all diagnostics as well as the feedback processors for commissioning and fault diagnosis. Results of studies and the design effort are reported.« less
Development of a vision-based pH reading system
NASA Astrophysics Data System (ADS)
Hur, Min Goo; Kong, Young Bae; Lee, Eun Je; Park, Jeong Hoon; Yang, Seung Dae; Moon, Ha Jung; Lee, Dong Hoon
2015-10-01
pH paper is generally used for pH interpretation in the QC (quality control) process of radiopharmaceuticals. pH paper is easy to handle and useful for small samples such as radio-isotopes and radioisotope (RI)-labeled compounds for positron emission tomography (PET). However, pHpaper-based detecting methods may have some errors due limitations of eye sight and inaccurate readings. In this paper, we report a new device for pH reading and related software. The proposed pH reading system is developed with a vision algorithm based on the RGB library. The pH reading system is divided into two parts. First is the reading device that consists of a light source, a CCD camera and a data acquisition (DAQ) board. To improve the accuracy of the sensitivity, we utilize the three primary colors of the LED (light emission diode) in the reading device. The use of three colors is better than the use of a single color for a white LED because of wavelength. The other is a graph user interface (GUI) program for a vision interface and report generation. The GUI program inserts the color codes of the pH paper into the database; then, the CCD camera captures the pH paper and compares its color with the RGB database image in the reading mode. The software captures and reports information on the samples, such as pH results, capture images, and library images, and saves them as excel files.
NASA Astrophysics Data System (ADS)
Forcier, Bob
2003-09-01
This paper describes a digital-ultrasonic ground network, which forms an unique "unattended mote sensor system" for monitoring the environment, personnel, facilities, vehicles, power generation systems or aircraft in Counter-Terrorism, Force Protection, Prognostic Health Monitoring (PHM) and other ground applications. Unattended wireless smart sensor/tags continuously monitor the environment and provide alerts upon changes or disruptions to the environment. These wireless smart sensor/tags are networked utilizing ultrasonic wireless motes, hybrid RF/Ultrasonic Network Nodes and Base Stations. The network is monitored continuously with a 24/7 remote and secure monitoring system. This system utilizes physical objects such as a vehicle"s structure or a building to provide the media for two way secure communication of key metrics and sensor data and eliminates the "blind spots" that are common in RF solutions because of structural elements of buildings, etc. The digital-ultrasonic sensors have networking capability and a 32-bit identifier, which provide a platform for a robust data acquisition (DAQ) for a large amount of sensors. In addition, the network applies a unique "signature" of the environment by comparing sensor-to-sensor data to pick up on minute changes, which would signal an invasion of unknown elements or signal a potential tampering in equipment or facilities. The system accommodates satellite and other secure network uplinks in either RF or UWB protocols. The wireless sensors can be dispersed by ground or air maneuvers. In addition, the sensors can be incorporated into the structure or surfaces of vehicles, buildings, or clothing of field personnel.
Towards a Cyber Defense Framework for SCADA Systems Based on Power Consumption Monitoring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez Jimenez, Jarilyn M; Chen, Qian; Nichols, Jeff A.
Supervisory control and data acquisition (SCADA) is an industrial automation system that remotely monitor, and control critical infrastructures. SCADA systems are major targets for espionage and sabotage attackers. According to the 2015 Dell security annual threat report, the number of cyber-attacks against SCADA systems has doubled in the past year. Cyber-attacks (i.e., buffer overflow, rootkits and code injection) could cause serious financial losses and physical infrastructure damages. Moreover, some specific cyber-attacks against SCADA systems could become a threat to human life. Current commercial off-the-shelf security solutions are insufficient in protecting SCADA systems against sophisticated cyber-attacks. In 2014 a report bymore » Mandiant stated that only 69% of organizations learned about their breaches from third entities, meaning that these companies lack of their own detection system. Furthermore, these breaches are not detected in real-time or fast enough to prevent further damages. The average time between compromise and detection (for those intrusions that were detected) was 205 days. To address this challenge, we propose an Intrusion Detection System (IDS) that detects SCADA-specific cyber-attacks by analyzing the power consumption of a SCADA device. Specifically, to validate the proposed approach, we chose to monitor in real-time the power usage of a a Programmable Logic Controller (PLC). To this end, we configured the hardware of the tetsbed by installing the required sensors to monitor and collect its power consumption. After that two SCADA-specific cyber-attacks were simulated and TracerDAQ Pro was used to collect the power consumption of the PLC under normal and anomalous scenarios. Results showed that is possible to distinguish between the regular power usage of the PLC and when the PLC was under specific cyber-attacks.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.
Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.; ...
2016-12-28
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.
NASA Astrophysics Data System (ADS)
Schambach, J.; Rossewij, M. J.; Sielewicz, K. M.; Aglieri Rinella, G.; Bonora, M.; Ferencei, J.; Giubilato, P.; Vanat, T.
2016-12-01
The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. This contribution describes laboratory and radiation testing results with this prototype board set.
Impulsiveness, and trait displaced aggression among drug using female sex traders
Clingan, Sarah E.; Fisher, Dennis G.; Pedersen, William C.; Reynolds, Grace L.; Xandre, Pamela
2016-01-01
Objective This study compared women who sex trade for drugs, money, or both compared to neither (did not sex trade), and introduced the concept of trait displaced aggression to the literature on sex trading. Methods Female participants (n = 1055) were recruited from a low-income area of southern California. Measures included: the Risk Behavior Assessment (RBA), Barratt Impulsivity Scale (BIS), Eysenck Impulsiveness Scale (EIS), and the Displaced Aggression Questionnaire (DAQ). Results Women who traded sex for both drugs and money used crack cocaine, powder cocaine, and alcohol significantly more, scored higher on the BIS, and the EIS, and were significantly older. Those who only sex traded for drugs used more amphetamine, heroin, and injected drugs more days. They were also higher on the DAQ and all of the DAQ subscales. Those who traded for money only used marijuana more and were more likely to use marijuana before sex. Conclusions This study may help address specific issues unique to those who sex trade for different commodities in that the drugs used are different and the underlying personality characteristics are different. PMID:27082265
Supernova neutrino detection in LZ
NASA Astrophysics Data System (ADS)
Khaitan, D.
2018-02-01
In the first 10 seconds of a core-collapse supernova, almost all of its progenitor's gravitational potential, O(1053 ergs), is carried away in the form of neutrinos. These neutrinos, with O(10 MeV) kinetic energy, can interact via coherent elastic neutrino-nucleus scattering (CEνNS) depositing O(1 keV) in detectors. In this work we describe the performances of low-background dark matter detectors, such as LUX-ZEPLIN (LZ), optimized for detecting low-energy depositions, in detecting these neutrino interactions. For instance, a 27 Msolar supernova at 10 kpc is expected to produce ~350 neutrino interactions in the 7-tonne liquid xenon active volume of LZ. Based on the LS220 EoS neutrino flux model for a SN, the Noble Element Simulation Technique (NEST), and predicted CEνNS cross-sections for xenon, to study energy deposition and detection of SN neutrinos in LZ. We simulate the response of the LZ data acquisition system (DAQ) and demonstrate its capability and limitations in handling this interaction rate. We present an overview of the LZ detector, focusing on the benefits of liquid xenon for supernova neutrino detection. We discuss energy deposition and detector response simulations and their results. We present an analysis technique to reconstruct the total number of neutrinos and the time of the supernova core bounce.
Readout electronics for CBM-TOF super module quality evaluation based on 10 Gbps ethernet
NASA Astrophysics Data System (ADS)
Jiang, D.; Cao, P.; Huang, X.; Zheng, J.; Wang, Q.; Li, B.; Li, J.; Liu, S.; An, Q.
2017-07-01
The Compressed Baryonic Matter-Time of Flight (CBM-TOF) wall uses high performance of Multi-gap Resistive Plate Chambers (MRPC) assembled in super modules to identify charged particles with high channel density and high measurement precision at high event rate. Electronics meet the challenge for reading data out from a super module at high speed of about 6 Gbps in real time. In this paper, the readout electronics for CBM-TOF super module quality evaluation is proposed based on 10 Gigabit Ethernet. The digitized TOF data from one super module will be concentrated at the front-end electronics residing on the side of the super module and transmitted to an extreme speed readout module (XSRM) housed in the backend crate through the PCI Express (PCIe) protocol via optic channels. Eventually, the XSRM transmits data to the data acquisition (DAQ) system through four 10 Gbps Ethernet ports in real time. This readout structure has advantages of high performance and expansibility. Furthermore, it is easy to operate. Test results on the prototype show that the overall data readout performance for each XSRM can reach up to 28.8 Gbps, which means XSRM can meet the requirement of reading data out from 4 super modules with 1280 channels in real time.
NASA Astrophysics Data System (ADS)
Altini, V.; Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F.; Divià, R.; Fuchs, U.; Makhlyueva, I.; Roukoutakis, F.; Schossmaier, K.; Soòs, C.; Vande Vyvre, P.; Von Haller, B.; ALICE Collaboration
2010-04-01
All major experiments need tools that provide a way to keep a record of the events and activities, both during commissioning and operations. In ALICE (A Large Ion Collider Experiment) at CERN, this task is performed by the Alice Electronic Logbook (eLogbook), a custom-made application developed and maintained by the Data-Acquisition group (DAQ). Started as a statistics repository, the eLogbook has evolved to become not only a fully functional electronic logbook, but also a massive information repository used to store the conditions and statistics of the several online systems. It's currently used by more than 600 users in 30 different countries and it plays an important role in the daily ALICE collaboration activities. This paper will describe the LAMP (Linux, Apache, MySQL and PHP) based architecture of the eLogbook, the database schema and the relevance of the information stored in the eLogbook to the different ALICE actors, not only for near real time procedures but also for long term data-mining and analysis. It will also present the web interface, including the different used technologies, the implemented security measures and the current main features. Finally it will present the roadmap for the future, including a migration to the web 2.0 paradigm, the handling of the database ever-increasing data volume and the deployment of data-mining tools.
Mississippi State Axion Search
NASA Astrophysics Data System (ADS)
Madsen, Kris; Mississippi State Axion Search Collaboration
2013-10-01
Ever since the Peccei-Quinn Theory was proposed in 1977 as a possible solution to the strong CP problem, the therein postulated Axion, a weakly interacting boson, has been much sought after. The Mississippi State Axion Search is an attempt to improve the limit in the mass-coupling parameter space by using a variation of the Light Shining Through a Wall (LSW) technique. A vacuum sealed and RF shielded cavity is partitioned by a lead wall. EM waves at a frequency between 420 and 430 MHz are amplified by SR-550 and SR-510 amplifiers, broadcast from an antenna on one side of the lead wall and pass through an intense magnetic field. Theory predicts that in the presence of such a magnetic field, axions can be produced from photons via the Primakoff effect. Any axions generated will pass unimpeded to the other half of the cavity, regenerate into photons, and be detected as an excess in the signal picked up by the antenna on the far side. The Data Acquisition is handled by LABView based software running Measurement Computing drivers for two PCI DAQ cards: the DAS-08 handles the analog signals from the receiving antenna and monitors vital statistics in the cavity, while the DIO-24 provides the 1 kHz timing TTL pulse and allows remote control of the experiment's systems.
YARR - A PCIe based Readout Concept for Current and Future ATLAS Pixel Modules
NASA Astrophysics Data System (ADS)
Heim, Timon
2017-10-01
The Yet Another Rapid Readout (YARR) system is a DAQ system designed for the readout of current generation ATLAS Pixel FE-I4 and next generation chips. It utilises a commercial-off-the-shelf PCIe FPGA card as a reconfigurable I/O interface, which acts as a simple gateway to pipe all data from the Pixel modules via the high speed PCIe connection into the host system’s memory. Relying on modern CPU architectures, which enables the usage of parallelised processing in threads and commercial high speed interfaces in everyday computers, it is possible to perform all processing on a software level in the host CPU. Although FPGAs are very powerful at parallel signal processing their firmware is hard to maintain and constrained by their connected hardware. Software, on the other hand, is very portable and upgraded frequently with new features coming at no cost. A DAQ concept which does not rely on the underlying hardware for acceleration also eases the transition from prototyping in the laboratory to the full scale implementation in the experiment. The overall concept and data flow will be outlined, as well as the challenges and possible bottlenecks which can be encountered when moving the processing from hardware to software.
Design of the ANTARES LCM-DAQ board test bench using a FPGA-based system-on-chip approach
NASA Astrophysics Data System (ADS)
Anvar, S.; Kestener, P.; Le Provost, H.
2006-11-01
The System-on-Chip (SoC) approach consists in using state-of-the-art FPGA devices with embedded RISC processor cores, high-speed differential LVDS links and ready-to-use multi-gigabit transceivers allowing development of compact systems with substantial number of IO channels. Required performances are obtained through a subtle separation of tasks between closely cooperating programmable hardware logic and user-friendly software environment. We report about our experience in using the SoC approach for designing the production test bench of the off-shore readout system for the ANTARES neutrino experiment.
Muons in the CMS High Level Trigger System
NASA Astrophysics Data System (ADS)
Verwilligen, Piet; CMS Collaboration
2016-04-01
The trigger systems of LHC detectors play a fundamental role in defining the physics capabilities of the experiments. A reduction of several orders of magnitude in the rate of collected events, with respect to the proton-proton bunch crossing rate generated by the LHC, is mandatory to cope with the limits imposed by the readout and storage system. An accurate and efficient online selection mechanism is thus required to fulfill the task keeping maximal the acceptance to physics signals. The CMS experiment operates using a two-level trigger system. Firstly a Level-1 Trigger (L1T) system, implemented using custom-designed electronics, is designed to reduce the event rate to a limit compatible to the CMS Data Acquisition (DAQ) capabilities. A High Level Trigger System (HLT) follows, aimed at further reducing the rate of collected events finally stored for analysis purposes. The latter consists of a streamlined version of the CMS offline reconstruction software and operates on a computer farm. It runs algorithms optimized to make a trade-off between computational complexity, rate reduction and high selection efficiency. With the computing power available in 2012 the maximum reconstruction time at HLT was about 200 ms per event, at the nominal L1T rate of 100 kHz. An efficient selection of muons at HLT, as well as an accurate measurement of their properties, such as transverse momentum and isolation, is fundamental for the CMS physics programme. The performance of the muon HLT for single and double muon triggers achieved in Run I will be presented. Results from new developments, aimed at improving the performance of the algorithms for the harsher scenarios of collisions per event (pile-up) and luminosity expected for Run II will also be discussed.
Experimental Magnetohydrodynamic Energy Extraction from a Pulsed Detonation
2015-03-01
experimental data taken in this thesis will follow voltage profiles similar to Fig. 2. Notice the initial section in Fig. 2 shows exponential decay consistent...equal that time constant. The exponential curves in Fig. 2 show how changing the time constant can change the charge and/or discharge rate of the...see Fig. 1), at a sampling rate of 1 MHz. Shielded wire and a common ground were used throughout the DAQ system to avoid capacitive issues in the
Automated Liquid-Level Control of a Nutrient Reservoir for a Hydroponic System
NASA Technical Reports Server (NTRS)
Smith, Boris; Asumadu, Johnson A.; Dogan, Numan S.
1997-01-01
A microprocessor-based system for control of the liquid level of a nutrient reservoir for a plant hydroponic growing system has been developed. The system uses an ultrasonic transducer to sense the liquid level or height. A National Instruments' Multifunction Analog and Digital Input/Output PC Kit includes NI-DAQ DOS/Windows driver software for an IBM 486 personal computer. A Labview Full Development system for Windows is the graphical programming system being used. The system allows liquid level control to within 0.1 cm for all levels tried between 8 and 36 cm in the hydroponic system application. The detailed algorithms have been developed and a fully automated microprocessor based nutrient replenishment system has been described for this hydroponic system.
The TOTEM T1 read out card motherboard
NASA Astrophysics Data System (ADS)
Minutoli, S.; Lo Vetere, M.; Robutti, E.
2010-12-01
This article describes the Read Out Card (ROC) motherboard, which is the main component of the T1 forward telescope front-end electronic system. The ROC main objectives are to acquire tracking data and trigger information from the detector. It performs data conversion from electrical to optical format and transfers the data streams to the next level of the system and it implements Slow Control modules which are able to receive, decode and distribute the LHC machine low jitter clock and fast command. The ROC also provides a spy mezzanine connection based on programmable FPGA and USB2.0 for laboratory and portable DAQ debugging system.
Development of a Position Decoding ASIC for SPECT using Silicon Photomultiplier
NASA Astrophysics Data System (ADS)
Cho, M.; Kim, H.; Lim, K. T.; Cho, G.
2016-01-01
Single Photon Emission Computed Tomography(SPECT) is a widely used diagnosis modality for detecting metabolic diseases. In general, SPECT system is consisted of a sensor, a pre-amplifier, position decoding circuits(PDC) and a data acquisition(DAQ) system. Due to such complexity, it is quite costly to assemble SPECT system by putting discrete components together. Moreover, using discrete components would make the system rather bulky. In this work, we designed a channel module ASIC for SPECT system. This system was composed of a transimpedance amplifier(TIA), comparators and digital logics. In this particular module, a TIA was selected as a preamplifier because the decay time and the rise time are shorter than that of other preamplifier topologies. In the proposed module, the amplified pulse from the TIA was split into two separate signals and each signal was then fed into two comparators with different reference levels, e.g., a low and high level. Then an XOR gate combined the comparator outputs and the output of XOR gate was sent to the suceeding digital logic. Furthermore, the output of each component in the module is composed of a signal packet. The packet includes the information on the energy, the time and the position of the incident photon. The energy and position information of a detected radiation can be derived from the output of the D-flipflop(DFF) in the module via time-over-threshold(TOT). The timing information was measured using a delayed rising edge from the low-level referenced comparator. There are several advantages in developing the channel module ASIC. First of all, the ASIC has only digital outputs and thus a correction circuit for analog signal distortion can be neglected. In addition, it is possible to cut down the system production cost because the volume of the system can be reduced due to the compactness of ASIC. The benefits of channel module is not only limited to SPECT but also beneficial to many other radiation detecting systems.
NASA Technical Reports Server (NTRS)
Spivey, Reggie A.; Gilley, Scott; Ostrogorsky, Aleksander; Grugel, Richard; Smith, Guy; Luz, Paul
2003-01-01
The Solidification Using a Baffle in Sealed Ampoules (SUBSA) and Pore Formation and Mobility Investigation (PFMI) furnaces were developed for operation in the International Space Station (ISS) Microgravity Science Glovebox (MSG). Both furnaces were launched to the ISS on STS-111, June 4, 2002, and are currently in use on orbit. The SUBSA furnace provides a maximum temperature of 850 C and can accommodate a metal sample as large as 30 cm long and 12mm in diameter. SUBSA utilizes a gradient freeze process with a minimum cooldown rate of 0.5C per min, and a stability of +/- 0.15C. An 8 cm long transparent gradient zone coupled with a Cohu 3812 camera and quartz ampoule allows for observation and video recording of the solidification process. PFMI is a Bridgman type furnace that operates at a maximum temperature of 130C and can accommodate a sample 23cm long and 10mm in diameter. Two Cohu 3812 cameras mounted 90 deg apart move on a separate translation system which allows for viewing of the sample in the transparent hot zone and gradient zone independent of the furnace translation rate and direction. Translation rates for both the cameras and furnace can be specified from 0.5micrometers/sec to 100 micrometers/sec with a stability of +/-5%. The two furnaces share a Process Control Module (PCM) which controls the furnace hardware, a Data Acquisition Pad (DaqPad) which provides signal condition of thermal couple data, and two Cohu 3812 cameras. The hardware and software allow for real time monitoring and commanding of critical process control parameters. This paper will provide a detailed explanation of the SUBSA and PFMI systems along with performance data and some preliminary results from completed on-orbit processing runs.
Dynamic performances analysis of a real vehicle driving
NASA Astrophysics Data System (ADS)
Abdullah, M. A.; Jamil, J. F.; Salim, M. A.
2015-12-01
Vehicle dynamic is the effects of movement of a vehicle generated from the acceleration, braking, ride and handling activities. The dynamic behaviours are determined by the forces from tire, gravity and aerodynamic which acting on the vehicle. This paper emphasizes the analysis of vehicle dynamic performance of a real vehicle. Real driving experiment on the vehicle is conducted to determine the effect of vehicle based on roll, pitch, and yaw, longitudinal, lateral and vertical acceleration. The experiment is done using the accelerometer to record the reading of the vehicle dynamic performance when the vehicle is driven on the road. The experiment starts with weighing a car model to get the center of gravity (COG) to place the accelerometer sensor for data acquisition (DAQ). The COG of the vehicle is determined by using the weight of the vehicle. A rural route is set to launch the experiment and the road conditions are determined for the test. The dynamic performance of the vehicle are depends on the road conditions and driving maneuver. The stability of a vehicle can be controlled by the dynamic performance analysis.
Electronics for a highly segmented electromagnetic calorimeter prototype
NASA Astrophysics Data System (ADS)
Fehlker, D.; Alme, J.; van den Brink, A.; de Haas, A. P.; Nooren, G.-J.; Reicher, M.; Röhrich, D.; Rossewij, M.; Ullaland, K.; Yang, S.
2013-03-01
A prototype of a highly segmented electromagnetic calorimeter has been developed. The detector tower is made of 24 layers of PHASE2/MIMOSA23 silicon sensors sandwiched between tungsten plates, with 4 sensors per layer, a total of 96 MIMOSA sensors, resulting in 39 MPixels for the complete prototype detector tower. The paper focuses on the electronics of this calorimeter prototype. Two detector readout and control systems are used, each containing two Spartan 6 and one Virtex 6 FPGA, running embedded Linux, each system serving 12 detector layers. In 550 ms a total of 4 Gbytes of data is read from the detector, stored in memory on the electronics and then shipped to the DAQ system via Gigabit ethernet.
Madasamy, Thangamuthu; Pandiaraj, Manickam; Balamurugan, Murugesan; Karnewar, Santosh; Benjamin, Alby Robson; Venkatesh, Krishna Arun; Vairamani, Kanagavel; Kotamraju, Srigiridhar; Karunakaran, Chandran
2012-10-15
In this work, we have designed and developed a novel and cost effective virtual electrochemical analyzer for the measurement of NO in exhaled breath and from hydrogen peroxide stimulated endothelial cells using home-made potentiostat. Here, data acquisition system (NI MyDAQ) was used to acquire the data from the electrochemical oxidation of NO mediated by copper, zinc superoxide dismutase (Cu,ZnSOD). The electrochemical control programs (graphical user-interface software) were developed using LabVIEW 10.0 to sweep the potential, acquire the current response and process the acquired current signal. The Cu,ZnSOD (SOD1) immobilized on the carbon nanotubes in polypyrrole modified platinum electrode was used as the NO biosensor. The electrochemical behavior of the SOD1 modified electrode exhibited the characteristic quasi-reversible redox peak at the potential, +0.06 V vs. Ag/AgCl. The biological interferences were eliminated by nafion coated SOD1 electrode and then NO was measured selectively. Further, this biosensor showed a wide linear range of response over the concentration of NO from 0.1 μM to 1 mM with a detection limit of 0.1 μM and high sensitivity of 1.1 μA μM(-1). The electroanalytical results obtained here using the developed virtual electrochemical instrument were also compared with the standard cyclic voltammetry instrument and found in agreement with each other. Copyright © 2012 Elsevier B.V. All rights reserved.
Fast Inference of Deep Neural Networks in FPGAs for Particle Physics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duarte, Javier; Han, Song; Harris, Philip
Recent results at the Large Hadron Collider (LHC) have pointed to enhanced physics capabilities through the improvement of the real-time event processing techniques. Machine learning methods are ubiquitous and have proven to be very powerful in LHC physics, and particle physics as a whole. However, exploration of the use of such techniques in low-latency, low-power FPGA hardware has only just begun. FPGA-based trigger and data acquisition (DAQ) systems have extremely low, sub-microsecond latency requirements that are unique to particle physics. We present a case study for neural network inference in FPGAs focusing on a classifier for jet substructure which wouldmore » enable, among many other physics scenarios, searches for new dark sector particles and novel measurements of the Higgs boson. While we focus on a specific example, the lessons are far-reaching. We develop a package based on High-Level Synthesis (HLS) called hls4ml to build machine learning models in FPGAs. The use of HLS increases accessibility across a broad user community and allows for a drastic decrease in firmware development time. We map out FPGA resource usage and latency versus neural network hyperparameters to identify the problems in particle physics that would benefit from performing neural network inference with FPGAs. For our example jet substructure model, we fit well within the available resources of modern FPGAs with a latency on the scale of 100 ns.« less
Zhou, Yu; Ren, Jie
2011-04-01
We put forward a new concept of software oversampling mapping system for electrocardiogram (ECG) to assist the research of the ECG inverse problem to improve the generality of mapping system and the quality of mapping signals. We then developed a conceptual system based on the traditional ECG detecting circuit, Labview and DAQ card produced by National Instruments, and at the same time combined the newly-developed oversampling method into the system. The results indicated that the system could map ECG signals accurately and the quality of the signals was good. The improvement of hardware and enhancement of software made the system suitable for mapping in different situations. So the primary development of the software for oversampling mapping system was successful and further research and development can make the system a powerful tool for researching ECG inverse problem.
System interface for an integrated intelligent safety system (ISS) for vehicle applications.
Hannan, Mahammad A; Hussain, Aini; Samad, Salina A
2010-01-01
This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications.
System Interface for an Integrated Intelligent Safety System (ISS) for Vehicle Applications
Hannan, Mahammad A.; Hussain, Aini; Samad, Salina A.
2010-01-01
This paper deals with the interface-relevant activity of a vehicle integrated intelligent safety system (ISS) that includes an airbag deployment decision system (ADDS) and a tire pressure monitoring system (TPMS). A program is developed in LabWindows/CVI, using C for prototype implementation. The prototype is primarily concerned with the interconnection between hardware objects such as a load cell, web camera, accelerometer, TPM tire module and receiver module, DAQ card, CPU card and a touch screen. Several safety subsystems, including image processing, weight sensing and crash detection systems, are integrated, and their outputs are combined to yield intelligent decisions regarding airbag deployment. The integrated safety system also monitors tire pressure and temperature. Testing and experimentation with this ISS suggests that the system is unique, robust, intelligent, and appropriate for in-vehicle applications. PMID:22205861
calorimeter, Shower Max., Preshower, Crack Chambers (1979-present) Run II Upgrade: Front end electronics (QIE , Preshower electronics and DAQ Support for Level-2 electron and photon triggers (RECES and ISO) Deputy Head
Odell, Annie P; Reynolds, Grace L; Fisher, Dennis G; Huckabay, Loucine M; Pedersen, William C; Xandre, Pamela; Miočević, Milica
2017-05-01
This study compares adults with and without attention deficit hyperactivity disorder (ADHD) on measures of direct and displaced aggression and illicit drug use. Three hundred ninety-six adults were administered the Wender Utah Rating Scale, the Risk Behavior Assessment, the Aggression Questionnaire (AQ), and the Displaced Aggression Questionnaire (DAQ). Those with ADHD were higher on all scales of the AQ and DAQ, were younger at first use of amphetamines, and were more likely to have ever used crack and amphetamines. A Structural Equation Model found a significant interaction in that for those with medium and high levels of verbal aggression, ADHD predicts crack and amphetamine. Follow-up logistic regression models suggest that blacks self-medicate with crack and whites and Hispanics self-medicate with amphetamine when they have ADHD and verbal aggression.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zalesak, Jaroslav; et al.
2014-01-01
The NOνA experiment is a long-baseline neutrino experiment designed to make measurements to determine the neutrino mass hierarchy, neutrino mixing parameters and CP violation in the neutrino sector. In order to make these measurements the NOνA collaboration has designed a highly distributed, synchronized, continuous digitization and readout system that is able to acquire and correlate data from the Fermilab accelerator complex (NuMI), the NOνA near detector at the Fermilab site and the NOνA far detector which is located 810 km away at Ash River, MN. This system has unique properties that let it fully exploit the physics capabilities of themore » NOνA detector. The design of the NOνA DAQ system and its capabilities are discussed in this paper.« less
The new Wide-band Solar Neutrino Trigger for Super-Kamiokande
NASA Astrophysics Data System (ADS)
Carminati, Giada
Super-Kamiokande observes low energy electrons induced by the elastic scattering of 8B solar neutrinos. The transition region between vacuum and matter oscillations, with neutrino energy near 3 MeV, is still partially unexplored by any detector. Super-Kamiokande can study this intermediate regime adding a new software trigger. The Wide-band Intelligent Trigger (WIT) has been developed to simultaneously trigger and reconstruct very low energy electrons (above 2.49 kinetic MeV) with an e_ciency close to 100%. The WIT system, comprising 256-Hyperthreaded CPU cores and one 10-Gigabit Ethernet network switch, has been recently installed and integrated in the online DAQ system of SK and the complete system is currently in an advanced status of online data testing.
Lifetime of MCP-PMTs and other performance features
NASA Astrophysics Data System (ADS)
Lehmann, A.; Böhm, M.; Eyrich, W.; Miehling, D.; Pfaffinger, M.; Stelter, S.; Uhlig, F.; Ali, A.; Belias, A.; Dzhygadlo, R.; Gerhardt, A.; Götzen, K.; Kalicy, G.; Krebs, M.; Lehmann, D.; Nerling, F.; Patsyuk, M.; Peters, K.; Schepers, G.; Schmitt, L.; Schwarz, C.; Schwiening, J.; Traxler, M.; Düren, M.; Etzelmüller, E.; Föhl, K.; Hayrapetyan, A.; Kreutzfeld, K.; Merle, O.; Rieke, J.; Schmidt, M.; Wasem, T.; Achenbach, P.; Cardinali, M.; Hoek, M.; Lauth, W.; Schlimme, S.; Sfienti, C.; Thiel, M.
2018-02-01
The bar PANDA experiment at FAIR will use DIRC detectors for the separation of hadrons. The compactness of the bar PANDA detector requires the image planes of these detectors to be placed inside the magnetic field of the solenoid. Due to this and other boundary conditions MCP-PMTs were identified as the only suitable photon sensors. Until recently the major obstacle for an application of MCP-PMTs in high rate experiments like bar PANDA were serious aging problems which led to damage at the photo-cathode and a fast declining quantum efficiency as the integrated anode charge (IAC) increased. With new countermeasures against the aging, in particular due to the application of an atomic layer deposition (ALD) technique to coat the MCP pores, the lifetime of MCP-PMTs has meanwhile increased by a factor >50 which is fully sufficient for bar PANDA. The recent results of our long-term lifetime measurements are discussed. New 2-inch MCP-PMT prototypes from Hamamatsu show an encouraging behavior. However, the currently best performing MCP-PMT is a 2-inch PHOTONIS tube with two ALD-layers which reaches an IAC of >16 C/cm2 without any visible sign of aging. In the second part of these proceedings a new data acquisition system of the PADIWA/TRB type is presented which allows a quasi-parallel measurement of many MCP-PMT performance parameters. Especially unwanted effects like dark-count rate, crosstalk, ion after-pulsing, and recoil electrons can be studied in more detail than ever before. Exemplary results for these parameters are shown. The discussed DAQ system will be used for the comprehensive data quality checks of the MCP-PMTs being built into the DIRCs.
SU-E-T-159: Characteristics of Fiber-Optic Radiation Sensor for Proton Therapeutic Beam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Son, J; Kim, M; Hwang, U
Purpose: A fiber-optic radiation sensor using Cerenkov radiation has been widely studied for use as a dosimeter for proton therapeutic beam. Although the fiber-optic radiation sensor has already been investigated for proton therapeutic, it has been examined relatively little work for clinical therapeutic proton beams. In this study, we evaluated characteristics of a fiber-optic radiation sensor for clinical therapeutic proton beams. We experimentally evaluated dose-rate dependence, dose response and energy dependence for the proton beam. Methods: A fiber-optic radiation sensor was placed in a water phantom. Beams with energies of low, middle and high were used in the passively-scattered protonmore » therapeutic beam at the National Cancer Center in Korea. The sensor consists of two plastic optical fibers (POF). A reference POF and 2 cm longer POF were used to utilize the subtraction method for having sensitive volume. Each POF is optically coupled to the Multi-Anode Photo Multiplier Tube (MAPMT) and the MAPMT signals are processed using National Instruments Data Acquisition System (NI-DAQ). We were investigated dosimetric properties including dose-rate dependence, dose response and energy dependence. Results: We have successfully evaluated characteristics of a fiber optic radiation sensor using Cerenkov radiation. The fiber-optic radiation sensor showed the dose response linearity and low energy dependence. In addition, as the dose-rate was increased, Cerenkov radiation increased linearly. Conclusion: We evaluated the basic characteristics of the fiber optic radiation sensor, the dosimetry tool, to raise the quality of proton therapy. Based on the research, we developed a real time dosimetry system of the optic fiber to confirm the real time beam position and energy for therapeutic proton pencil beam.« less
Designing the detection system for the CORUS project
NASA Astrophysics Data System (ADS)
Kalogirou, A.
2013-05-01
CORUS (Cosmic Rays in UK Schools) will be a network of muon detectors based in schools across the UK. Networks similar to CORUS already exist in other countries, such as the Netherlands and USA. The main aim of the project is to teach high schools students about cosmic rays and experimental physics as well as to motivate them to pursue studies in science. A set of muon detectors will be used for this purpose and the objective of this study is to complete the design of the detectors, construct them and test their capabilities and limitations. The most important component of the muon detector is the electronic card used to collect, analyse and output data. A DAQ card used by QuarkNet, a network of detectors in the USA, has been used in the design of the CORUS detectors. Some readily available photomultiplier tubes have also been used, along with an interface board which connects them to the DAQ board. In this study, I tested whether these two components work well together by conducting a series of experiments, intended to be performed by the students, with the nal detector set-up. The end result is that although a number of improvements is needed before the detectors serve their purpose, this particular set-up does not impose any limitations to the experiments that it is intended to be used for.
486-7162 70A-2255A 70A2255 manager for DAQ Hardware Gerald Przybylski Electronics Engineer 510 486 subsystem. Thorsten Stezelberger Electronics Engineer 510 495-2489 50A-6141A 50R5008 Designing and fixing
An FPGA-based trigger for the phase II of the MEG experiment
NASA Astrophysics Data System (ADS)
Baldini, A.; Bemporad, C.; Cei, F.; Galli, L.; Grassi, M.; Morsani, F.; Nicolò, D.; Ritt, S.; Venturini, M.
2016-07-01
For the phase II of MEG, we are going to develop a combined trigger and DAQ system. Here we focus on the former side, which operates an on-line reconstruction of detector signals and event selection within 450 μs from event occurrence. Trigger concentrator boards (TCB) are under development to gather data from different crates, each connected to a set of detector channels, to accomplish higher-level algorithms to issue a trigger in the case of a candidate signal event. We describe the major features of the new system, in comparison with phase I, as well as its performances in terms of selection efficiency and background rejection.
Experiences with ATM in a multivendor pilot system at Forschungszentrum Julich
NASA Astrophysics Data System (ADS)
Kleines, H.; Ziemons, K.; Zwoll, K.
1998-08-01
The ATM technology for high speed serial transmission provides a new quality of communication by introducing novel features in a LAN environment, especially support of real time communication, of both LAN and WAN communication and of multimedia streams. In order to evaluate ATM for future DAQ systems and remote control systems as well as for a high speed picture archiving and communications system for medical images, Forschungszentrum Julich has build up a pilot system for the evaluation of ATM and standard low cost multimedia systems. It is a heterogeneous multivendor system containing a variety of switches and desktop solutions, employing different protocol options of ATM. The tests conducted in the pilot system revealed major difficulties regarding stability, interoperability and performance. The paper presents motivations, layout and results of the pilot system. Discussion of results concentrates on performance issues relevant for realistic applications, e.g., connection to a RAID system via NFS over ATM.
Readout and trigger for the AFP detector at ATLAS experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kocian, M.
AFP, the ATLAS Forward Proton consists of silicon detectors at 205 m and 217 m on each side of ATLAS. In 2016 two detectors in one side were installed. The FEI4 chips are read at 160 Mbps over the optical fibers. The DAQ system uses a FPGA board with Artix chip and a mezzanine card with RCE data processing module based on a Zynq chip with ARM processor running ArchLinux. Finally, in this paper we give an overview of the AFP detector with the commissioning steps taken to integrate with the ATLAS TDAQ. Furthermore first performance results are presented.
Readout and trigger for the AFP detector at ATLAS experiment
Kocian, M.
2017-01-25
AFP, the ATLAS Forward Proton consists of silicon detectors at 205 m and 217 m on each side of ATLAS. In 2016 two detectors in one side were installed. The FEI4 chips are read at 160 Mbps over the optical fibers. The DAQ system uses a FPGA board with Artix chip and a mezzanine card with RCE data processing module based on a Zynq chip with ARM processor running ArchLinux. Finally, in this paper we give an overview of the AFP detector with the commissioning steps taken to integrate with the ATLAS TDAQ. Furthermore first performance results are presented.
Rakovska, Angelina; Baranyi, Maria; Windisch, Katalin; Petkova-Kirova, Polina; Gagov, Hristo; Kalfin, Reni
2017-09-01
CART (Cocaine- and Amphetamine-Regulated Transcript) peptide is a neurotransmitter naturally occurring in the CNS and found mostly in nucleus accumbens, ventrotegmental area, ventral pallidum, amygdalae and striatum, brain regions associated with drug addiction. In the nucleus accumbens, known for its significant role in motivation, pleasure, reward and reinforcement learning, CART peptide inhibits cocaine and amphetamine-induced dopamine-mediated increases in locomotor activity and behavior, suggesting a CART peptide interaction with the dopaminergic system. Thus in the present study, we examined the effect of CART (55-102) peptide on the basal, electrical field stimulation-evoked (EFS-evoked) (30V, 2Hz, 120 shocks) and returning basal dopamine (DA) release and on the release of the DA metabolites 3,4-dihydroxyphenyl acetaldehyde (DOPAL), 3,4-dihydroxyphenylacetic acid (DOPAC), homovanillic acid (HVA), 3,4-dihydroxyphenylethanol (DOPET), 3-methoxytyramine (3-MT) as well as on norepinephrine (NE) and dopamine-o-quinone (Daq) in isolated mouse nucleus accumbens, in a preparation, in which any CART peptide effects on the dendrites or soma of ventral tegmental projection neurons have been excluded. We further extended our study to assess the effect of CART (55-102) peptide on basal cocaine-induced release of dopamine and its metabolites DOPAL, DOPAC, HVA, DOPET and 3-MT as well as on NE and Daq. To analyze the amount of [ 3 H]dopamine, dopamine metabolites, Daq and NE in the nucleus accumbens superfusate, a high-pressure liquid chromatography (HPLC), coupled with electrochemical, UV and radiochemical detections was used. CART (55-102) peptide, 0.1μM, added alone, exerted: (i) a significant decrease in the basal and EFS-evoked levels of extracellular dopamine (ii) a significant increase in the EFS-evoked and returning basal levels of the dopamine metabolites DOPAC and HVA, major products of dopamine degradation and (iii) a significant decrease in the returning basal levels of DOPET. At the same concentration, 0.1μM, CART (55-102) peptide did not have any effect on the release of noradrenaline. In the presence of CART (55-102) peptide, 0.1μM, the effect of cocaine, 30μM, on the basal dopamine release was inhibited and the effect on the basal DOPAC release substantially increased. To our knowledge, our findings are the first to show direct neurochemical evidence that CART (55-102) peptide plays a neuromodulatory role on the dopaminergic reward system by decreasing dopamine in the mouse nucleus accumbens and by attenuating cocaine-induced effects on dopamine release. Copyright © 2017 Elsevier Inc. All rights reserved.
A new OTDR based on probe frequency multiplexing
NASA Astrophysics Data System (ADS)
Lu, Lidong; Liang, Yun; Li, Binglin; Guo, Jinghong; Zhang, Xuping
2013-12-01
Two signal multiplexing methods are proposed and experimentally demonstrated in optical time domain reflectometry (OTDR) for fault location of optical fiber transmission line to obtain high measurement efficiency. Probe signal multiplexing is individually obtained by phase modulation for generation of multi-frequency and time sequential frequency probe pulses. The backscattered Rayleigh light of the multiplexing probe signals is transferred to corresponding heterodyne intermediate frequency (IF) through heterodyning with the single frequency local oscillator (LO). Then the IFs are simultaneously acquired by use of a data acquisition card (DAQ) with sampling rate of 100Msps, and the obtained data are processed by digital band pass filtering (BPF), digital down conversion (DDC) and digital low pass filtering (BPF) procedure. For each probe frequency of the detected signals, the extraction of the time domain reflecting signal power is performed by parallel computing method. For a comprehensive performance comparison with conventional coherent OTDR on the probe frequency multiplexing methods, the potential for enhancement of dynamic range, spatial resolution and measurement time are analyzed and discussed. Experimental results show that by use of the probe frequency multiplexing method, the measurement efficiency of coherent OTDR can be enhanced by nearly 40 times.
Espinoza, A; Beeksma, B; Petasecca, M; Fuduli, I; Porumb, C; Cutajar, D; Corde, S; Jackson, M; Lerch, M L F; Rosenfeld, A B
2013-11-01
High dose rate (HDR) brachytherapy is a radiation treatment technique capable of delivering large dose rates to the tumor. Radiation is delivered using remote afterloaders to drive highly active sources (commonly (192)Ir with an air KERMA strength range between 20,000 and 40,000 U, where 1 U = 1 μGy m(2)/h in air) through applicators directly into the patient's prescribed region of treatment. Due to the obvious ramifications of incorrect treatment while using such an active source, it is essential that there are methods for quality assurance (QA) that can directly and accurately verify the treatment plan and the functionality of the remote afterloader. This paper describes the feasibility study of a QA system for HDR brachytherapy using a phantom based two-dimensional 11 × 11 epitaxial diode array, named "magic phantom." The HDR brachytherapy treatment plan is translated to the phantom with two rows of 10 (20 in total) HDR source flexible catheters, arranged above and below the diode array "magic plate" (MP). Four-dimensional source tracking in each catheter is based upon a developed fast iterative algorithm, utilizing the response of the diodes in close proximity to the (192)Ir source, sampled at 100 ms intervals by a fast data acquisition (DAQ) system. Using a (192)Ir source in a solid water phantom, the angular response of the developed epitaxial diodes utilized in the MP and also the variation of the MP response as a function of the source-to-detector distance (SDD) were investigated. These response data are then used by an iterative algorithm for source dwelling position determination. A measurement of the average transit speed between dwell positions was performed using the diodes and a fast DAQ. The angular response of the epitaxial diode showed a variation of 15% within 360°, with two flat regions above and below the detector face with less than 5% variation. For SDD distances of between 5 and 30 mm the relative response of the epitaxial diodes used in the MP is in good agreement (within 8%) with radial dose function measurements found within the TG-43 protocol, with SDD of up to 70 mm showing a 40% over response. A method for four-dimensional localization of the HDR source was developed, allowing the source dwell position to be derived within 0.50 mm of the expected position. An estimation of the average transit speed for varying step sizes was determined and was found to increase from (12.8 ± 0.3) up to (38.6 ± 0.4) cm/s for a step size of 2.5 and 50 mm, respectively. Our characterization of the designed QA "magic phantom" with MP in realistic HDR photon fields demonstrates the promising performance for real-time source position tracking in four dimensions and measurements of transit times. Further development of this system will allow a full suite for QA in HDR brachytherapy and analysis, and for future in vivo tracking.
The Austrian radiation monitoring network ARAD - best practice and added value
NASA Astrophysics Data System (ADS)
Olefs, Marc; Baumgartner, Dietmar J.; Obleitner, Friedrich; Bichler, Christoph; Foelsche, Ulrich; Pietsch, Helga; Rieder, Harald E.; Weihs, Philipp; Geyer, Florian; Haiden, Thomas; Schöner, Wolfgang
2016-04-01
The Austrian RADiation monitoring network (ARAD) has been established to advance the national climate monitoring and to support satellite retrieval, atmospheric modeling and the development of solar energy techniques. Measurements cover the downward solar and thermal infrared radiation using instruments according to Baseline Surface Radiation Network (BSRN) standards. A unique feature of ARAD is its vertical dimension of five stations, covering an altitude range between about 200 m a.s.l (Vienna) and 3100 m a.s.l. (BSRN site Sonnblick). The paper outlines the aims and scopes of ARAD, its measurement and calibration standards, methods, strategies and station locations. ARAD network operation uses innovative data processing for quality assurance and quality control, utilizing manual and automated control algorithms. A combined uncertainty estimate for the broadband shortwave radiation fluxes at all five ARAD stations, using the methodology specified by the Guide to the Expression of Uncertainty in Measurement indicates that relative accuracies range from 1.5 to 2.9 % for large signals (global, direct: 1000 W m-2, diffuse: 500 W m-2) and from 1.7 to 23 % (or 0.9 to 11.5 W m-2) for small signals (50 W m-2) (expanded uncertainties corresponding to the 95 % confidence level). If the directional response error of the pyranometers and the temperature response of the instruments and the data acquisition system (DAQ) are corrected, this expanded uncertainty reduces to 1.4 to 2.8 % for large signals and to 1.7 to 5.2 % (or 0.9-2.6 W m-2) for small signals. Thus, for large signals of global and diffuse radiation, BSRN target accuracies are met or nearly met (missed by less than 0.2 percentage points, pps) for 70 % of the ARAD measurements after this correction. For small signals of direct radiation, BSRN targets are achieved at two sites and nearly met (also missed by less than 0.2 pps) at the other sites. For small signals of global and diffuse radiation, targets are achieved at all stations. Additional accuracy gains can be achieved in the future through additional measurements, corrections and a further upgrade of the DAQ. However, to improve the accuracy of measurements of direct solar radiation, improved instrument accuracy is needed. ARAD could serve as a useful example for establishing state-of-the-art radiation monitoring at the national level with a multiple-purpose approach. Instrumentation, guidelines and tools (such as the data quality control) developed within ARAD are intended to increase monitoring capabilities of global radiation and thus designed to allow straightforward adoption in other regions, without high development costs.
The KLOE-2 high energy taggers
NASA Astrophysics Data System (ADS)
Curciarello, F.
2017-06-01
The precision measurement of the π0 → γγ width allows to gain insights into the low-energy QCD dynamics. A way to achieve the precision needed (1%) in order to test theory predictions is to study the π0 production through γγ fusion in the e+e- → e+e-γ*γ* → e+e-π0 reaction. The KLOE-2 experiment, currently running at the DAΦNE facility in Frascati, aims to perform this measurement. For this reason, new detectors, which allow to tag final state leptons, have been installed along the DAΦNE beam line in order to reduce the background coming from phi-meson decays. The High Energy Tagger (HET) detector measures the deviation of leptons from their main orbit by determining their position and timing. The HET detectors are placed in roman pots just at the exit of the DAΦNE dipole magnets, 11 m away from the IP, both on positron and electron sides. The HET sensitive area is made up of a set of 28 plastic scintillators. A dedicated DAQ electronic board, based on a Xilinx Virtex-5 FPGA, has been developed for this detector. It provides a MultiHit TDC with a time resolution of 550(1) ps and the possibility to clearly identify the correct bunch crossing (ΔTbunch ~ 2.7 ns). The most relevant features of the KLOE-2 tagging system operation as time performance, stability and the techniques used to determine the time overlap between the KLOE and HET asynchronous DAQs will be presented.
Development of brain PET using GAPD arrays.
Jung, Jin Ho; Choi, Yong; Hong, Key Jo; Kang, Jihoon; Hu, Wei; Lim, Hyun Keong; Huh, Yoonsuk; Kim, Sangsu; Jung, Jiwoong; Kim, Kyu Bom
2012-03-01
In recent times, there has been great interest in the use of Geiger-mode avalanche photodiodes (GAPDs) as scintillator readout in positron emission tomography (PET) detectors because of their advantages, such as high gain, compact size, low power consumption, and magnetic field insensitivity. The purpose of this study was to develop a novel PET system based on GAPD arrays for brain imaging. The PET consisted of 72 detector modules arranged in a ring of 330 mm diameter. Each PET module was composed of a 4 × 4 matrix of 3 × 3 × 20 mm(3) cerium-doped lutetium yttrium orthosilicate (LYSO) crystals coupled with a 4 × 4 array three-side tileable GAPD. The signals from each PET module were fed into preamplifiers using a 3 m long flat cable and then sent to a position decoder circuit (PDC), which output a digital address and an analog pulse of the interacted channel among 64 preamplifier signals transmitted from four PET detector modules. The PDC outputs were fed into field programmable gate array (FPGA)-embedded data acquisition (DAQ) boards. The analog signal was then digitized, and arrival time and energy of the signal were calculated and stored. The energy and coincidence timing resolutions measured for 511 keV gamma rays were 18.4 ± 3.1% and 2.6 ns, respectively. The transaxial spatial resolution and sensitivity in the center of field of view (FOV) were 3.1 mm and 0.32% cps/Bq, respectively. The rods down to a diameter of 2.5 mm were resolved in a hot-rod phantom image, and activity distribution patterns between the white and gray matters in the Hoffman brain phantom were well imaged. Experimental results indicate that a PET system can be developed using GAPD arrays and the GAPD-based PET system can provide high-quality PET imaging.
The LHCb trigger and its upgrade
NASA Astrophysics Data System (ADS)
Dziurda, A.; LHCb Trigger Group
2016-07-01
The current LHCb trigger system consists of a hardware level, which reduces the LHC inelastic collision rate of 30 MHz, at which the entire detector is read out. In a second level, implemented in a farm of 20 k parallel-processing CPUs, the event rate is reduced to about 5 kHz. We review the performance of the LHCb trigger system during Run I of the LHC. Special attention is given to the use of multivariate analyses in the High Level Trigger. The major bottleneck for hadronic decays is the hardware trigger. LHCb plans a major upgrade of the detector and DAQ system in the LHC shutdown of 2018, enabling a purely software based trigger to process the full 30 MHz of inelastic collisions delivered by the LHC. We demonstrate that the planned architecture will be able to meet this challenge.
Nehra, Ashima; Singla, Sweta; Bajpai, Swati; Malviya, Shrividhya; Padma, Vasantha; Tripathi, Manjari
2014-10-01
Stigma associated with epilepsy has negative effects on psychosocial outcomes, affecting quality of life (QOL) and increasing disease burden in persons with epilepsy (PWEs). The aim of our study was to measure the impact of stigma on the QOL of PWEs and the prevalence of neurological disability due to stigmatized epilepsy. A prospective observational study with a sample of 208 PWEs was conducted. Neuropsychological Tests used were the Indian Disability Evaluation Assessment Scale (IDEAS) to measure disability, the Dysfunctional Analysis Questionnaire (DAQ) to measure QOL, and the Stigma Scale for Epilepsy (SSE) to assess stigma. Spearman correlation was calculated, and stigma (SSE) was highly significant with QOL (DAQ) (0.019) and disability due to stigmatized epilepsy (IDEAS) (0.011). The present study supports the global perception of stigma associated with epilepsy and its negative impact on their overall QOL and its contribution to the escalation of the disease burden. Copyright © 2014 Elsevier Inc. All rights reserved.
SU-E-T-317: Dynamic Modulated Brachytherapy (DMBT): Robotic Applicator Design.
Han, Dae Yup; Webster, Matthew J; Devic, Slobodan; Vuong, Te; Scanderbeg, Dan; Song, William Y
2012-06-01
To investigate the hardware necessary for implementing our Dynamic Modulated Brachytherapy (DMBT) treatment concept for rectal cancer. The DMBT robot has three major parts: 1) shield and shield delivery module, 2) controlling module, and 3) DMBT controlling and monitoring software. The shield is a tungsten alloy cylinder (r=0.95cm, l=4.5cm) with a 5.5mm rectangular-shaped opening. The shield is controlled by an aluminum pipe with gear set (1:3) and linear actuator (2mm/turn). An Ir-192 radiation source will be placed through the aluminum pipe. The power source is a Nema-17 stepping motor with EvoDrive ST-17 (EVA Robotics, Queensland, Australia) and USB-6009 DAQ (National Instrument, Austin, TX). With our in-house operating program through LabView (National Instrument, Austin, TX), we can make and load plans for treatment as well as testing. Checking the shield position is also possible through the operating program. For safety, a lexan sheath tube and emergency buttons are built-in. The DMBT robot has 2 degrees of freedom, which are linear translation and rotation. With our power delivery system, the spatial resolutions are 0.0125mm (linear stage) and 0.012Ëš (rotation). In 0.5s, motors achieve the desired position with the maximum speeds 450 step/s (1Ëš), 7,500 step/s (30Ëš), and 12,000 step/s (5mm). Four registers are triggered with USB-6009 DAQ signals. The operating program includes gages for checking shield position, loading treatment plans, and safety buttons. In all, we have designed the hardware components of the DMBT system for rectal cancer. For treatment, the system needs more elements to support the DMBT robot; lexan sheath tube holder, DMBT robot security joint, and a system for reducing friction between the tube and shield. We will also refine our system to be more compact by using DC servomotors instead of the larger Nema-17 stepping motors. © 2012 American Association of Physicists in Medicine.
Lu, Liang-Hsuan; Chiang, Shang-Lin; Wei, Shun-Hwa; Lin, Chueh-Ho; Sung, Wen-Hsu
2017-08-01
Being bedridden long-term can cause deterioration in patients' physiological function and performance, limiting daily activities and increasing the incidence of falls and other accidental injuries. Little research has been carried out in designing effective detecting systems to monitor the posture and status of bedridden patients and to provide accurate real-time feedback on posture. The purposes of this research were to develop a computer-aided system for real-time detection of physical activities in bed and to validate the system's validity and test-retest reliability in determining eight postures: motion leftward/rightward, turning over leftward/rightward, getting up leftward/rightward, and getting off the bed leftward/rightward. The in-bed physical activity detecting system consists mainly of a clinical sickbed, signal amplifier, a data acquisition (DAQ) system, and operating software for computing and determining postural changes associated with four load cell sensing components. Thirty healthy subjects (15 males and 15 females, mean age = 27.8 ± 5.3 years) participated in the study. All subjects were asked to execute eight in-bed activities in a random order and to participate in an evaluation of the test-retest reliability of the results 14 days later. Spearman's rank correlation coefficient was used to compare the system's determinations of postural states with researchers' recordings of postural changes. The test-retest reliability of the system's ability to determine postures was analyzed using the interclass correlation coefficient ICC(3,1). The system was found to exhibit high validity and accuracy (r = 0.928, p < 0.001; accuracy rate: 87.9%) in determining in-bed displacement, turning over, sitting up, and getting off the bed. The system was particularly accurate in detecting motion rightward (90%), turning over leftward (83%), sitting up leftward or rightward (87-93%), and getting off the bed (100%). The test-retest reliability ICC(3,1) value was 0.968 (p < 0.001). The system developed in this study exhibits satisfactory validity and reliability in detecting changes in-bed body postures and can be beneficial in assisting caregivers and clinical nursing staff in detecting the in-bed physical activities of bedridden patients and in developing fall prevention warning systems. Copyright © 2017 Elsevier B.V. All rights reserved.
ATLAS tile calorimeter cesium calibration control and analysis software
NASA Astrophysics Data System (ADS)
Solovyanov, O.; Solodkov, A.; Starchenko, E.; Karyukhin, A.; Isaev, A.; Shalanda, N.
2008-07-01
An online control system to calibrate and monitor ATLAS Barrel hadronic calorimeter (TileCal) with a movable radioactive source, driven by liquid flow, is described. To read out and control the system an online software has been developed, using ATLAS TDAQ components like DVS (Diagnostic and Verification System) to verify the hardware before running, IS (Information Server) for data and status exchange between networked computers, and other components like DDC (DCS to DAQ Connection), to connect to PVSS-based slow control systems of Tile Calorimeter, high voltage and low voltage. A system of scripting facilities, based on Python language, is used to handle all the calibration and monitoring processes from hardware perspective to final data storage, including various abnormal situations. A QT based graphical user interface to display the status of the calibration system during the cesium source scan is described. The software for analysis of the detector response, using online data, is discussed. Performance of the system and first experience from the ATLAS pit are presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-05
... Kentucky, through the Kentucky Energy and Environment Cabinet, Division for Air Quality (DAQ), to... (MVEBs) for nitrogen oxides (NO X ) and volatile organic compounds (VOC) for Northern Kentucky. This... control, Incorporation by reference, Nitrogen dioxide, Ozone, Intergovernmental relations, and Volatile...
. PDF file High pT muons in Cosmic-Ray Air Showers with IceCube. PDF file IceCube Performance with Artificial Light Sources: the road to a Cascade Analyses + Energy scale calibration for EHE. PDF file , 2006. PDF file Thorsten Stetzelberger "IceCube DAQ Design & Performance" Nov 2005 PPT
Photoacoustic imaging of prostate brachytherapy seeds with transurethral light delivery
NASA Astrophysics Data System (ADS)
Lediju Bell, Muyinatu A.; Guo, Xiaoyu; Song, Danny Y.; Boctor, Emad M.
2014-03-01
We present a novel approach to photoacoustic imaging of prostate brachytherapy seeds utilizing an existing urinary catheter for transurethral light delivery. Two canine prostates were surgically implanted with brachyther- apy seeds under transrectal ultrasound guidance. One prostate was excised shortly after euthanasia and fixed in gelatin. The second prostate was imaged in the native tissue environment shortly after euthanasia. A urinary catheter was inserted in the urethra of each prostate. A 1-mm core diameter optical fiber coupled to a 1064 nm Nd:YAG laser was inserted into the urinary catheter. Light from the fiber was either directed mostly parallel to the fiber axis (i.e. end-fire fire) or mostly 90° to the fiber axis (i.e. side-fire fiber). An Ultrasonix SonixTouch scanner, transrectal ultrasound probe with curvilinear (BPC8-4) and linear (BPL9-5) arrays, and DAQ unit were utilized for synchronized laser light emission and photoacoustic signal acquisition. The implanted brachytherapy seeds were visualized at radial distances of 6-16 mm from the catheter. Multiple brachytherapy seeds were si- multaneously visualized with each array of the transrectal probe using both delay-and-sum (DAS) and short-lag spatial coherence (SLSC) beamforming. This work is the first to demonstrate the feasibility of photoacoustic imaging of prostate brachytherapy seeds using a transurethral light delivery method.
Virtual Instrumentation for a Fiber-Optics-Based Artificial Nerve
NASA Technical Reports Server (NTRS)
Lyons, Donald R.; Kyaw, Thet Mon; Griffin, DeVon (Technical Monitor)
2001-01-01
A LabView-based computer interface for fiber-optic artificial nerves has been devised as a Masters thesis project. This project involves the use of outputs from wavelength multiplexed optical fiber sensors (artificial nerves), which are capable of producing dense optical data outputs for physical measurements. The potential advantages of using optical fiber sensors for sensory function restoration is the fact that well defined WDM-modulated signals can be transmitted to and from the sensing region allowing networked units to replace low-level nerve functions for persons desirous of "intelligent artificial limbs." Various FO sensors can be designed with high sensitivity and the ability to be interfaced with a wide range of devices including miniature shielded electrical conversion units. Our Virtual Instrument (VI) interface software package was developed using LabView's "Laboratory Virtual Instrument Engineering Workbench" package. The virtual instrument has been configured to arrange and encode the data to develop an intelligent response in the form of encoded digitized signal outputs. The architectural layout of our nervous system is such that different touch stimuli from different artificial fiber-optic nerve points correspond to gratings of a distinct resonant wavelength and physical location along the optical fiber. Thus, when an automated, tunable diode laser sends scans, the wavelength spectrum of the artificial nerve, it triggers responses that are encoded with different touch stimuli by way wavelength shifts in the reflected Bragg resonances. The reflected light is detected and a resulting analog signal is fed into ADC1 board and DAQ card. Finally, the software has been written such that the experimenter is able to set the response range during data acquisition.
The design, status and performance of the ZEUS central tracking detector electronics
NASA Astrophysics Data System (ADS)
Cussans, D. G.; Fawcett, H. F.; Foster, B.; Gilmore, R. S.; Heath, G. P.; Llewellyn, T. J.; Malos, J.; Morgado, C. J. S.; Tapper, R. J.; Gingrich, D. M.; Harnew, N.; Hallam-Baker, P.; Nash, J.; Khatri, T.; Shield, P. D.; McArthur, I.; Topp-Jorgensen, S.; Wilson, F. F.; Allen, D.; Baird, S. A.; Carter, R.; Galagardera, S.; Gibson, M. D.; Hatley, R. S.; Jeffs, M.; Milborrow, R.; Morissey, M.; Quinton, S. P. H.; White, D. J.; Lane, J.; Nixon, G.; Postranecky, M.; Jamdagni, A. K.; Marcou, C.; Miller, D. B.; Toudup, L.
1992-05-01
The readout system developed for the ZEUS central trackign detector (CDT) is described. The CTD is required to provide an accurate measurement of the sagitta and energy loss of charged particles as well as provide fast trigger information. This must be carried out in the HERA environment in which beams cross every 96 ns. The first two aims are achieved by digitizing chamber pulses using a pipelined 104 MHz FADC system. The trigger uses a fast determination of the difference in the arrival times of a pulse at each end of the CTD. It processes this data and gives information to the ZEUS global first level trigger. The modules are housed in custom-built racks and crates and read out using a DAQ system based on Transputer readout controllers. These also monitor data quality and produce data for the ZEUS second level Trigger.
Proof of concept of an imaging system demonstrator for PET applications with SiPM
NASA Astrophysics Data System (ADS)
Morrocchi, Matteo; Marcatili, Sara; Belcari, Nicola; Giuseppina Bisogni, Maria; Collazuol, Gianmaria; Ambrosi, Giovanni; Santoni, Cristiano; Corsi, Francesco; Foresta, Maurizio; Marzocca, Cristoforo; Matarrese, Gianvito; Sportelli, Giancarlo; Guerra, Pedro; Santos, Andres; Del Guerra, Alberto
2013-08-01
A PET imaging system demonstrator based on LYSO crystal arrays coupled to SiPM matrices is under construction at the University and INFN of Pisa. Two SiPM matrices, composed of 8×8 SiPM pixels, and 1,5 mm pitch, have been coupled one to one to a LYSO crystals array and read out by a custom electronics system. front-end ASICs were used to read 8 channels of each matrix. Data from each front-end were multiplexed and sent to a DAQ board for the digital conversion; a motherboard collects the data and communicates with a host computer through a USB port for the storage and off-line data processing. In this paper we show the first preliminary tomographic image of a point-like radioactive source acquired with part of the two detection heads in time coincidence.
Development of Network Interface Cards for TRIDAQ systems with the NaNet framework
NASA Astrophysics Data System (ADS)
Ammendola, R.; Biagioni, A.; Cretaro, P.; Di Lorenzo, S.; Fiorini, M.; Frezza, O.; Lamanna, G.; Lo Cicero, F.; Lonardo, A.; Martinelli, M.; Neri, I.; Paolucci, P. S.; Pastorelli, E.; Piandani, R.; Pontisso, L.; Rossetti, D.; Simula, F.; Sozzi, M.; Valente, P.; Vicini, P.
2017-03-01
NaNet is a framework for the development of FPGA-based PCI Express (PCIe) Network Interface Cards (NICs) with real-time data transport architecture that can be effectively employed in TRIDAQ systems. Key features of the architecture are the flexibility in the configuration of the number and kind of the I/O channels, the hardware offloading of the network protocol stack, the stream processing capability, and the zero-copy CPU and GPU Remote Direct Memory Access (RDMA). Three NIC designs have been developed with the NaNet framework: NaNet-1 and NaNet-10 for the CERN NA62 low level trigger and NaNet3 for the KM3NeT-IT underwater neutrino telescope DAQ system. We will focus our description on the NaNet-10 design, as it is the most complete of the three in terms of capabilities and integrated IPs of the framework.
Alternative Fuels Data Center: Utah's Clean Fuels and Vehicle Technology
vehicles, infrastructure, and equipment. As an agency of Utah's Department of Environmental Quality, DAQ legislation that created the fund typically sets forth other important provisions related to funding and , or a combination of the two. Enabling legislation also gives a state agency or department the
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-19
... plan (SIP) means that transportation activities will not produce new air quality violations, worsen...- Hour Ozone Sub-Area Motor Vehicle Emission Budgets for Transportation Conformity Purposes AGENCY... the North Carolina Department of Air Quality (NC DAQ), are adequate for transportation conformity...
Development of slow control system for the Belle II ARICH counter
NASA Astrophysics Data System (ADS)
Yonenaga, M.; Adachi, I.; Dolenec, R.; Hataya, K.; Iori, S.; Iwata, S.; Kakuno, H.; Kataura, R.; Kawai, H.; Kindo, H.; Kobayashi, T.; Korpar, S.; Križan, P.; Kumita, T.; Mrvar, M.; Nishida, S.; Ogawa, K.; Ogawa, S.; Pestotnik, R.; Šantelj, L.; Sumiyoshi, T.; Tabata, M.; Yusa, Y.
2017-12-01
A slow control system (SCS) for the Aerogel Ring Imaging Cherenkov (ARICH) counter in the Belle II experiment was newly developed and coded in the development frameworks of the Belle II DAQ software. The ARICH is based on 420 Hybrid Avalanche Photo-Detectors (HAPDs). Each HAPD has 144 pixels to be readout and requires 6 power supply (PS) channels, therefore a total number of 2520 PS channels and 60,480 pixels have to be configured and controlled. Graphical User Interfaces (GUIs) with detector oriented view and device oriented view, were also implemented to ease the detector operation. The ARICH SCS is in operation for detector construction and cosmic rays tests. The paper describes the detailed features of the SCS and preliminary results of operation of a reduced set of hardware which confirm the scalability to the full detector.
Ethernet based data logger for gaseous detectors
NASA Astrophysics Data System (ADS)
Swain, S.; Sahu, P. K.; Sahu, S. K.
2018-05-01
A data logger is designed to monitor and record ambient parameters such as temperature, pressure and relative humidity along with gas flow rate as a function of time. These parameters are required for understanding the characteristics of gas-filled detectors such as Gas Electron Multiplier (GEM) and Multi-Wire Proportional Counter (MWPC). The data logger has different microcontrollers and has been interfaced to an ethernet port with a local LCD unit for displaying all measured parameters. In this article, the explanation of the data logger design, hardware, and software description of the master microcontroller and the DAQ system along with LabVIEW interface client program have been presented. We have implemented this device with GEM detector and displayed few preliminary results as a function of above parameters.
NASA Astrophysics Data System (ADS)
Sharov, Vasily
2017-03-01
The features of the kinematics of elastic pp (dd) scattering in the collider system, as well as some issues concerning registration and selection of elastic scattering events in the NICA colliding beams are considered. Equality and the opposite direction of the scattered particle momenta provide a powerful selection criterion for elastic collisions. Variants of the organization of the trigger signal for recording tracks of secondary particles and DAQ system are given. The estimates of the characteristics of elastic NN processes are obtained from available dσ/dΩCM data for the elastic pp and np scattering. The paper presents examples of simulations using the Monte-Carlo of elastic pp scattering in the colliding proton beams and quasi-elastic np scattering in the colliding deuteron beams and evaluates the outputs of these processes at the NICA collider.
NASA Astrophysics Data System (ADS)
Szadkowski, Zbigniew
2016-06-01
The paper presents first results from the Front-End Board (FEB) with the biggest Cyclone® V E FPGA 5CEFA9F31I7N, supporting 8 channels sampled up to 250 MSps @ 14-bit resolution. Considered sampling for the planned upgrade of the Pierre Auger surface detector array is 120 MSps, however, the FEB has been developed with external anti-aliasing filters to keep a maximal flexibility. Six channels are targeted to the SD, two the rest for other experiments like: Auger Engineering Radio Array and additional muon counters. More channels and higher sampling generate larger size of registered events. We used the standard radio channel for a radio transmission from the detectors to the Central Data Acquisition Station (CDAS) to avoid at present a significant modification of a software in both sides: the detector and the CDAS (planned in a future for a final design). Several variants of the FPGA code were tested for 120, 160, 200 and even 240 MSps DAQ. Tests confirmed a stability and reliability of the FEB design in real pampas conditions with more than 40°C daily temperature variation and a strong sun exposition with a limited power budget only from a single solar panel. Seven FEBs have been deployed in a hexagon of test detectors on a dedicated Engineering Array.
First Results from the Telescope Array RAdar (TARA) Detector
NASA Astrophysics Data System (ADS)
Myers, Isaac
2014-03-01
The TARA cosmic ray detector has been in operation for about a year and a half. This bi-static radar detector was designed with the goal of detecting cosmic rays in coincidence with Telescope Array (TA). A new high power (25 kW, 5 MW effective radiated power) transmitter and antenna array and 250 MHz fPGA-based DAQ have been operational since August 2013. The eight-Yagi antenna array broadcasts a 54.1 MHz tone across the TA surface detector array toward our receiver station 50 km away at the Long Ridge fluorescence detector. Receiving antennas feed an intelligent DAQ that self-adjusts to the fluctuating radio background and which employs a bank of matched filters that search in real-time for chirp radar echoes. Millions of triggers have been collected in this mode. A second mode is a forced trigger scheme that uses the trigger status of the fluorescence telescope. Of those triggers collected in FD-triggered mode, about 800 correspond with well-reconstructed TA events. I will describe recent advancements in calibrating key components in the transmitter and receiver RF chains and the analysis of FD-triggered data. Work supported by W.M. Keck Foundation and NSF.
The CMS tracker control system
NASA Astrophysics Data System (ADS)
Dierlamm, A.; Dirkes, G. H.; Fahrer, M.; Frey, M.; Hartmann, F.; Masetti, L.; Militaru, O.; Shah, S. Y.; Stringer, R.; Tsirou, A.
2008-07-01
The Tracker Control System (TCS) is a distributed control software to operate about 2000 power supplies for the silicon modules of the CMS Tracker and monitor its environmental sensors. TCS must thus be able to handle about 104 power supply parameters, about 103 environmental probes from the Programmable Logic Controllers of the Tracker Safety System (TSS), about 105 parameters read via DAQ from the DCUs in all front end hybrids and from CCUs in all control groups. TCS is built on top of an industrial SCADA program (PVSS) extended with a framework developed at CERN (JCOP) and used by all LHC experiments. The logical partitioning of the detector is reflected in the hierarchical structure of the TCS, where commands move down to the individual hardware devices, while states are reported up to the root which is interfaced to the broader CMS control system. The system computes and continuously monitors the mean and maximum values of critical parameters and updates the percentage of currently operating hardware. Automatic procedures switch off selected parts of the detector using detailed granularity and avoiding widespread TSS intervention.
Proceedings of the workshop on B physics at hadron accelerators
DOE Office of Scientific and Technical Information (OSTI.GOV)
McBride, P.; Mishra, C.S.
1993-12-31
This report contains papers on the following topics: Measurement of Angle {alpha}; Measurement of Angle {beta}; Measurement of Angle {gamma}; Other B Physics; Theory of Heavy Flavors; Charged Particle Tracking and Vertexing; e and {gamma} Detection; Muon Detection; Hadron ID; Electronics, DAQ, and Computing; and Machine Detector Interface. Selected papers have been indexed separately for inclusion the in Energy Science and Technology Database.
Development of a beam test telescope based on the Alibava readout system
NASA Astrophysics Data System (ADS)
Marco-Hernández, R.
2011-01-01
A telescope for a beam test have been developed as a result of a collaboration among the University of Liverpool, Centro Nacional de Microelectrónica (CNM) of Barcelona and Instituto de Física Corpuscular (IFIC) of Valencia. This system is intended to carry out both analogue charge collection and spatial resolution measurements with different types of microstrip or pixel silicon detectors in a beam test environment. The telescope has four XY measurement as well as trigger planes (XYT board) and it can accommodate up to twelve devices under test (DUT board). The DUT board uses two Beetle ASICs for the readout of chilled silicon detectors. The board could operate in a self-triggering mode. The board features a temperature sensor and it can be mounted on a rotary stage. A peltier element is used for cooling the DUT. Each XYT board measures the track space points using two silicon strip detectors connected to two Beetle ASICs. It can also trigger on the particle tracks in the beam test. The board includes a CPLD which allows for the synchronization of the trigger signal to a common clock frequency, delaying and implementing coincidence with other XYT boards. An Alibava mother board is used to read out and to control each XYT/DUT board from a common trigger signal and a common clock signal. The Alibava board has a TDC on board to have a time stamp of each trigger. The data collected by each Alibava board is sent to a master card by means of a local data/address bus following a custom digital protocol. The master board distributes the trigger, clock and reset signals. It also merges the data streams from up to sixteen Alibava boards. The board has also a test channel for testing in a standard mode a XYT or DUT board. This board is implemented with a Xilinx development board and a custom patch board. The master board is connected with the DAQ software via 100M Ethernet. Track based alignment software has also been developed for the data obtained with the DAQ software.
Characterization Techniques for a MEMS Electric-Field Sensor in Vacuum
2012-01-01
nected so that the noise contributions of the transimpedance amplifier and the digitizer may be determined. The raw voltage data, after processing...of Vrms/rtHz. The noise may be seen in terms of the device trans- duction physics, signal conditioning ( transimpedance amp), and DAQ. (right) Field...Sensor using Thermal Actua- tors with Mechanically Amplified Response,” Solid-State Sensors, Actuators and Microsystems Confer- ence, 2007. TRANSDUCERS
Experimental Investigation and Numerical Predication of a Cross-Flow Fan
2006-12-01
Figure 3. Combination probes and pressure tap layout .....................................................6 Figure 4. CFF_DAQ graphical user interface...properties were United Sensor Devices model USD-C-161 3 mm (1/8-inch) combination thermocouple/pressure probes, and static pressure taps . The...was applied to the three static pressure tapes at the throat of the bell-mouth and to the two exhaust duct static pressure taps . Once the data
Neighborhood noise pollution as a determinant of displaced aggression: a pilot study.
Dzhambov, Angel; Dimitrova, Donka
2014-01-01
Noise pollution is still a growing public health problem with a significant impact on psychological health and well-being. The aim of this study was to investigate the impact of noise on displaced aggression (DA) in different subgroups of residents in one of the neighborhoods of Plovdiv city. A cross-sectional semi-structured interview survey was conducted using specially designed data registration forms and 33 close-ended and open-ended questions, divided into two major panels - one original and a modified version of the Displaced Aggression Questionnaire (DAQ). The mean score for DA was 61.12 (±19.97). Hearing noises above the perceived normal threshold, higher noise sensitivity and continuous noises were associated with higher levels of DA. Low frequency and high intensity noises were also associated with higher DA scores. Multiple regression model supported these findings. Contradictory to previous research age was positively correlated with noise sensitivity and aggression. We speculated that this might be due to the relatively lower socio-economic standard and quality of life in Bulgaria. Therefore, social climate might be modifying the way people perceive and react to environmental noise. Finally, the DAQ proved to be a viable measurement tool of these associations and might be further implemented and modified to suit the purposes of psychoacoustic assessment.
Tracking Detector Performance and Data Quality in the NOvA Experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Behera, Biswaranjan
NOvA is a long-baseline neutrino oscillation experiment. It uses the NuMI beam from Fermilab and two sampling calorimeter detectors located off-axis from the beam. The NOvA experiment measures the rate of electron-neutrino appearance in the almost pure muon-neutrino NuMI beam, with the data measured at the Near Detector being used to accurately determine the expected rate at the Far Detector. It is very important to have automated and accurate monitoring of the data recorded by the detectors so any hardware, DAQ or beam issues arising in the 344k (20k) channels of the Far (Near) detector which could affect the qualitymore » of the data taking are determined. This paper will cover the techniques and detector monitoring systems in various stages of data taking.« less
Measurement system for determination of current-voltage characteristics of PV modules
NASA Astrophysics Data System (ADS)
Idzkowski, Adam; Walendziuk, Wojciech; Borawski, Mateusz; Sawicki, Aleksander
2015-09-01
The realization of a laboratory stand for testing photovoltaic panels is presented here. The project of the laboratory stand was designed in SolidWorks software. The aim of the project was to control the electrical parameters of a PV panel. For this purpose a meter that measures electrical parameters i.e. voltage, current and power, was realized. The meter was created with the use of LabJack DAQ device and LabVIEW software. The presented results of measurements were obtained in different conditions (variable distance from the source of light, variable tilt angle of the panel). Current voltage characteristics of photovoltaic panel were created and all parameters could be detected in different conditions. The standard uncertainties of sample voltage, current, power measurements were calculated. The paper also gives basic information about power characteristics and efficiency of a solar cell.
48 CFR 304.7001 - Numbering acquisitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Numbering acquisitions. 304.7001 Section 304.7001 Federal Acquisition Regulations System HEALTH AND HUMAN SERVICES GENERAL ADMINISTRATIVE MATTERS Acquisition Instrument Identification Numbering System 304.7001 Numbering acquisitions. (a...
Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology.
Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M B
2015-01-01
This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet.
Labview Based ECG Patient Monitoring System for Cardiovascular Patient Using SMTP Technology
Singh, Om Prakash; Mekonnen, Dawit; Malarvili, M. B.
2015-01-01
This paper leads to developing a Labview based ECG patient monitoring system for cardiovascular patient using Simple Mail Transfer Protocol technology. The designed device has been divided into three parts. First part is ECG amplifier circuit, built using instrumentation amplifier (AD620) followed by signal conditioning circuit with the operation amplifier (lm741). Secondly, the DAQ card is used to convert the analog signal into digital form for the further process. Furthermore, the data has been processed in Labview where the digital filter techniques have been implemented to remove the noise from the acquired signal. After processing, the algorithm was developed to calculate the heart rate and to analyze the arrhythmia condition. Finally, SMTP technology has been added in our work to make device more communicative and much more cost-effective solution in telemedicine technology which has been key-problem to realize the telediagnosis and monitoring of ECG signals. The technology also can be easily implemented over already existing Internet. PMID:27006940
DOE Office of Scientific and Technical Information (OSTI.GOV)
Szadkowski, Zbigniew
2015-07-01
The paper presents the first results from the Front- End Board (FEB) with the biggest Cyclone{sup R} V E FPGA 5CEFA9F31I7N, supporting 8 channels sampled up to 250 MSps at 14-bit resolution. Considered sampling for the SD is 120 MSps, however, the FEB has been developed with external anti-aliasing filters to keep a maximal flexibility. Six channels are targeted to the SD, two the rest for other experiments like: Auger Engineering Radio Array and additional muon counters. More channels and higher sampling generate larger size of registered events. We used the standard radio channel for a radio transmission from themore » detectors to the Central Data Acquisition Station (CDAS) to avoid at present a significant modification of a software in both sides: the detector and the CDAS (planned in a future for a final design). Seven FEBs have been deployed in the test detectors on a dedicated Engineering Array in a hexagon. Several variants of the FPGA code were tested for 120, 160, 200 and even 240 MSps DAQ. Tests confirmed a stability and reliability of the FEB design in real pampas conditions with more than 40 deg. C daily temperature variation and a strong sun exposition with a limited power budget only from a single solar panel. (authors)« less
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Policy. 201.301 Section 201.301 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 201.301 Policy. (a...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 246.404 Section 246.404 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 246.404 Section 246.404 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 246.404 Section 246.404 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 246.404 Section 246.404 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 246.404 Section 246.404 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CONTRACT MANAGEMENT QUALITY ASSURANCE...
Upgrade project and plans for the ATLAS detector and trigger
NASA Astrophysics Data System (ADS)
Pastore, Francesca; Atlas Collaboration
2013-08-01
The LHC is expected to under go upgrades over the coming years in order to extend its scientific potential. Through two different phases (namely Phase-I and Phase-II), the average luminosity will be increased by a factor 5-10 above the design luminosity, 1034 cm-2 s-1. Consequently, the LHC experiments will need upgraded detectors and new infrastructure of the trigger and DAQ systems, to take into account the increase of radiation level and of particle rates foreseen at such high luminosity. In this paper we describe the planned changes and the investigations for the ATLAS experiment, focusing on the requirements for the trigger system to handle the increase rate of collisions per beam crossing, while maintaining widely inclusive selections. In different steps, the trigger detectors will improve their selectivity by benefiting from increased granularity. To improve the flexibility of the system, the use of the tracking information in the lower levels of the trigger selection is also discussed. Lastly different scenarios are compared, based on the expected physics potential of ATLAS in this high luminosity regime.
Combining endoscopic ultrasound with Time-Of-Flight PET: The EndoTOFPET-US Project
NASA Astrophysics Data System (ADS)
Frisch, Benjamin
2013-12-01
The EndoTOFPET-US collaboration develops a multimodal imaging technique for endoscopic exams of the pancreas or the prostate. It combines the benefits of high resolution metabolic imaging with Time-Of-Flight Positron Emission Tomography (TOF PET) and anatomical imaging with ultrasound (US). EndoTOFPET-US consists of a PET head extension for a commercial US endoscope and a PET plate outside the body in coincidence with the head. The high level of miniaturization and integration creates challenges in fields such as scintillating crystals, ultra-fast photo-detection, highly integrated electronics, system integration and image reconstruction. Amongst the developments, fast scintillators as well as fast and compact digital SiPMs with single SPAD readout are used to obtain the best coincidence time resolution (CTR). Highly integrated ASICs and DAQ electronics contribute to the timing performances of EndoTOFPET. In view of the targeted resolution of around 1 mm in the reconstructed image, we present a prototype detector system with a CTR better than 240 ps FWHM. We discuss the challenges in simulating such a system and introduce reconstruction algorithms based on graphics processing units (GPU).
48 CFR 3401.000 - Scope of part.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Scope of part. 3401.000 Section 3401.000 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM 3401.000 Scope of part. The Federal Acquisition Regulation System...
2016-04-30
Defense: Doing Data Right in Weapon System Acquisition Nancy Moore, Senior Management Scientist, RAND Megan McKernan, Defense Research Analyst...Access to Acquisition Data & Information in the Department of Defense: Doing Data Right in Weapon System Acquisition Nancy Moore, Senior Management...With Access to Acquisition Data and Information in the Department of Defense: Doing Data Right in Weapon System Acquisition Nancy Y. Moore—is a
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Policy. 1601.301 Section 1601.301 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Policy. 1601.301 Section 1601.301 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Policy. 7.102 Section 7.102 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Plans 7.102 Policy. (a) Agencies shall perform acquisition planning and...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Policy. 7.102 Section 7.102 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Plans 7.102 Policy. (a) Agencies shall perform acquisition planning and...
48 CFR 18.113 - Interagency acquisitions under the Economy Act.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Interagency acquisitions under the Economy Act. 18.113 Section 18.113 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES EMERGENCY ACQUISITIONS Available Acquisition Flexibilities 18.113 Interagency acquisitions under...
48 CFR 1.303 - Publication and codification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Publication and codification. 1.303 Section 1.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1.303 Publication and codification...
48 CFR Appendix - Federal Acquisition Regulation (FAR) Index
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Federal Acquisition Regulation (FAR) Index Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT USE OF GOVERNMENT SOURCES BY CONTRACTORS Contractor Use of Interagency Fleet Management System...
48 CFR 252.211-7000 - Acquisition streamlining.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Acquisition streamlining. 252.211-7000 Section 252.211-7000 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE CLAUSES AND FORMS SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text...
48 CFR 1.303 - Publication and codification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Publication and codification. 1.303 Section 1.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1.303 Publication and codification...
48 CFR 1.303 - Publication and codification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Publication and codification. 1.303 Section 1.303 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1.303 Publication and codification...
48 CFR 207.471 - Funding requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Funding requirements. 207.471 Section 207.471 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE ACQUISITION PLANNING ACQUISITION PLANNING Equipment Lease or Purchase 207.471 Funding...
48 CFR 207.471 - Funding requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Funding requirements. 207.471 Section 207.471 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE ACQUISITION PLANNING ACQUISITION PLANNING Equipment Lease or Purchase 207.471 Funding...
48 CFR 207.471 - Funding requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Funding requirements. 207.471 Section 207.471 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE ACQUISITION PLANNING ACQUISITION PLANNING Equipment Lease or Purchase 207.471 Funding...
48 CFR 207.471 - Funding requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Funding requirements. 207.471 Section 207.471 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE ACQUISITION PLANNING ACQUISITION PLANNING Equipment Lease or Purchase 207.471 Funding...
48 CFR 3401.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Agency control and compliance procedures. 3401.304 Section 3401.304 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations...
48 CFR 3046.790 - Use of warranties in major systems acquisitions by the USCG (USCG).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Use of warranties in major systems acquisitions by the USCG (USCG). 3046.790 Section 3046.790 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) CONTRACT MANAGEMENT QUALITY...
48 CFR 225.7303-3 - Government-to-government agreements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Government-to-government agreements. 225.7303-3 Section 225.7303-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Acquisitions for Foreign...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false General. 205.301 Section 205.301 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF... acquisition threshold that are for the acquisition of any clothing, fiber, yarn, or fabric items described in...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false General. 205.301 Section 205.301 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF... acquisition threshold that are for the acquisition of any clothing, fiber, yarn, or fabric items described in...
48 CFR 237.7001 - Method of acquisition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Method of acquisition. 237.7001 Section 237.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM... contract exists, use DD Form 1155, Order for Supplies or Services, to obtain mortuary services. ...
48 CFR 1.304 - Agency control and compliance procedures.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Agency control and compliance procedures. 1.304 Section 1.304 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1.304 Agency control...
Introduction to Defense Acquisition Management
1989-03-01
the system after Most new systems follow the same formatted and its usefullness in the weapon inventory predictable life cycle, and fit the model...natives for system concept development Statement (MNS) setting forth requirements need- -An acquisition strategy is developed to guide ed to meet the...6 BUSINESS, FINANCIAL AND TECHNICAL ASPECTS OF SYSTEMS ACQUISITION Management of the systems acquisition process The acquisition planning phase of the
First upper limits on the radar cross section of cosmic-ray induced extensive air showers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abbasi, R. U.; Abe, M.; Abou Bakr Othman, M.
TARA (Telescope Array Radar) is a cosmic ray radar detection experiment colocated with Telescope Array, the conventional surface scintillation detector (SD) and fluorescence telescope detector (FD) near Delta, Utah, U.S.A. Furthermore, the TARA detector combines a 40 kW, 54.1 MHz VHF transmitter and high-gain transmitting antenna which broadcasts the radar carrier over the SD array and within the FD field of view, towards a 250 MS/s DAQ receiver. TARA has been collecting data since 2013 with the primary goal of observing the radar signatures of extensive air showers (EAS). Simulations indicate that echoes are expected to be short in durationmore » (~10 µs) and exhibit rapidly changing frequency, with rates on the order 1 MHz/µs. The EAS radar cross-section (RCS) is currently unknown although it is the subject of over 70 years of speculation. One novel signal search technique is described in which the expected radar echo of a particular air shower is used as a matched filter template and compared to waveforms obtained by triggering the radar DAQ using the Telescope Array fluorescence detector. No evidence for the scattering of radio frequency radiation by EAS is obtained to date. Finally, we report the first quantitative RCS upper limits using EAS that triggered the Telescope Array Fluorescence Detector.« less
First upper limits on the radar cross section of cosmic-ray induced extensive air showers
Abbasi, R. U.; Abe, M.; Abou Bakr Othman, M.; ...
2016-11-19
TARA (Telescope Array Radar) is a cosmic ray radar detection experiment colocated with Telescope Array, the conventional surface scintillation detector (SD) and fluorescence telescope detector (FD) near Delta, Utah, U.S.A. Furthermore, the TARA detector combines a 40 kW, 54.1 MHz VHF transmitter and high-gain transmitting antenna which broadcasts the radar carrier over the SD array and within the FD field of view, towards a 250 MS/s DAQ receiver. TARA has been collecting data since 2013 with the primary goal of observing the radar signatures of extensive air showers (EAS). Simulations indicate that echoes are expected to be short in durationmore » (~10 µs) and exhibit rapidly changing frequency, with rates on the order 1 MHz/µs. The EAS radar cross-section (RCS) is currently unknown although it is the subject of over 70 years of speculation. One novel signal search technique is described in which the expected radar echo of a particular air shower is used as a matched filter template and compared to waveforms obtained by triggering the radar DAQ using the Telescope Array fluorescence detector. No evidence for the scattering of radio frequency radiation by EAS is obtained to date. Finally, we report the first quantitative RCS upper limits using EAS that triggered the Telescope Array Fluorescence Detector.« less
48 CFR 234.003 - Responsibilities.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Responsibilities. 234.003 Section 234.003 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SPECIAL CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION 234.003 Responsibilities. DoDD...
The ATLAS Tier-0: Overview and operational experience
NASA Astrophysics Data System (ADS)
Elsing, Markus; Goossens, Luc; Nairz, Armin; Negri, Guido
2010-04-01
Within the ATLAS hierarchical, multi-tier computing infrastructure, the Tier-0 centre at CERN is mainly responsible for prompt processing of the raw data coming from the online DAQ system, to archive the raw and derived data on tape, to register the data with the relevant catalogues and to distribute them to the associated Tier-1 centers. The Tier-0 is already fully functional. It has been successfully participating in all cosmic and commissioning data taking since May 2007, and was ramped up to its foreseen full size, performance and throughput for the cosmic (and short single-beam) run periods between July and October 2008. Data and work flows for collision data taking were exercised in several "Full Dress Rehearsals" (FDRs) in the course of 2008. The transition from an expert to a shifter-based system was successfully established in July 2008. This article will give an overview of the Tier-0 system, its data and work flows, and operations model. It will review the operational experience gained in cosmic, commissioning, and FDR exercises during the past year. And it will give an outlook on planned developments and the evolution of the system towards first collision data taking expected now in late Autumn 2009.
NASA Astrophysics Data System (ADS)
Gress, O.; Astapov, I.; Budnev, N.; Bezyazeekov, P.; Bogdanov, A.; Boreyko, V.; Brückner, M.; Chiavassa, A.; Chvalaev, O.; Dyachok, A.; Gress, T.; Epimakhov, S.; Fedoseev, E.; Gafarov, A.; Gorbunov, N.; Grebenyuk, V.; Grinuk, A.; Grishin, O.; Horns, D.; Ivanova, A.; Kalinin, A.; Karpov, N.; Kalmykov, N.; Kazarina, Yu.; Kirichkov, N.; Kiryuhin, S.; Kokoulin, R.; Komponiest, K.; Korosteleva, E.; Kozhin, V.; Kunnas, M.; Kuzmichev, L.; Lenok, V.; Lubsandorzhiev, B.; Lubsandorzhiev, N.; Mirgazov, R.; Mirzoyan, R.; Monkhoev, R.; Nachtigall, R.; Pakhorukov, A.; Panasyuk, M.; Pankov, L.; Petrukhin, A.; Platonov, V.; Poleschuk, V.; Popova, E.; Porelli, A.; Prosin, V.; Rubtsov, G.; Pushnin, A.; Samoliga, V.; Saunkin, A.; Semeney, Yu.; Shaibonov(ju), B.; Silaev, A.; Silaev(ju), A.; Skurikhin, A.; Slucka, V.; Spiering, C.; Sveshnikova, L.; Tabolenko, V.; Tarashchansky, B.; Tkachenko, A.; Tkachev, L.; Tluczykont, M.; Voronin, D.; Wischnewski, R.; Zagorodnikov, A.; Zurbanov, V.; Yashin, I.
2017-02-01
The new TAIGA-HiSCORE non-imaging Cherenkov array aims to detect air showers induced by gamma rays above 30 TeV and to study cosmic rays above 100 TeV. TAIGA-HiSCORE is made of integrating air Cherenkov detector stations with a wide field of view (0.6 sr), placed at a distance of about 100 m. They cover an area of initially ∼0.25 km2 (prototype array), and of ∼5 km2 at the final phase of the experiment. Each station includes 4 PMTs with 20 or 25 cm diameter, equipped with light guides shaped as Winstone cones. We describe the design, specifications of the read-out, DAQ and control and monitoring systems of the array. The present 28 detector stations of the TAIGA-HiSCORE engineering setup are in operation since September 2015.
48 CFR 34.000 - Scope of part.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Scope of part. 34.000... CONTRACTING MAJOR SYSTEM ACQUISITION General 34.000 Scope of part. This part describes acquisition policies... of an Earned Value Management System in acquisitions designated as major acquisitions consistent with...
48 CFR 34.000 - Scope of part.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Scope of part. 34.000... CONTRACTING MAJOR SYSTEM ACQUISITION General 34.000 Scope of part. This part describes acquisition policies... of an Earned Value Management System in acquisitions designated as major acquisitions consistent with...
48 CFR 34.000 - Scope of part.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Scope of part. 34.000... CONTRACTING MAJOR SYSTEM ACQUISITION General 34.000 Scope of part. This part describes acquisition policies... of an Earned Value Management System in acquisitions designated as major acquisitions consistent with...
48 CFR Appendix - Federal Acquisition Regulation (FAR) Index
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Federal Acquisition Regulation (FAR) Index Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT USE OF GOVERNMENT SOURCES BY CONTRACTORS Contractor Use of Interagency Fleet Management System (IFMS) Contract clause. FAR Index Federal...
48 CFR Appendix - Federal Acquisition Regulation (FAR) Index
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Federal Acquisition Regulation (FAR) Index Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT USE OF GOVERNMENT SOURCES BY CONTRACTORS Contractor Use of Interagency Fleet Management System (IFMS) Contract clause. FAR Index Federal...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Policy. 12.101 Section 12.101 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING ACQUISITION OF COMMERCIAL ITEMS Acquisition of Commercial Items-General 12.101 Policy. Agencies shall— (a...
48 CFR 225.7704-1 - Applicability of trade agreements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Applicability of trade agreements. 225.7704-1 Section 225.7704-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Acquisitions in Support of Operations in Afghanistan 225.7704-1...
48 CFR 225.7704-1 - Applicability of trade agreements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Applicability of trade agreements. 225.7704-1 Section 225.7704-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Acquisitions in Support of Operations in Iraq or Afghanistan...
48 CFR 225.7704-1 - Applicability of trade agreements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Applicability of trade agreements. 225.7704-1 Section 225.7704-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Acquisitions in Support of Operations in Afghanistan 225.7704-1...
48 CFR 213.302 - Purchase orders.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Purchase orders. 213.302 Section 213.302 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT... Acquisition Methods 213.302 Purchase orders. ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Copies. 201.105-3 Section 201.105-3 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 201.105-3 Copies. The...
48 CFR 3034.004 - Acquisition strategy.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Acquisition strategy. 3034.004 Section 3034.004 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND... Acquisition strategy. See (HSAR) 48 CFR 3009.570 for policy applicable to acquisition strategies that consider...
48 CFR 34.004 - Acquisition strategy.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the particular...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 46.404 Section 46.404 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 46.404 Section 46.404 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 46.404 Section 46.404 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 46.404 Section 46.404 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Government contract quality assurance for acquisitions at or below the simplified acquisition threshold. 46.404 Section 46.404 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACT MANAGEMENT QUALITY ASSURANCE Government Contract Quality Assurance...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-18
... Regulation Supplement for the transition of the Integrated Acquisition Environment systems to the new System... Acquisition Environment (IAE) is an electronic Government initiative that aggregates Federal acquisition...
48 CFR 201.201-1 - The two councils.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...
48 CFR 201.201-1 - The two councils.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...
48 CFR 201.201-1 - The two councils.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...
48 CFR 201.201-1 - The two councils.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...
48 CFR 201.201-1 - The two councils.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false The two councils. 201.201-1 Section 201.201-1 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Administration 201.201-1 The two...
48 CFR 908.7101-3 - Direct acquisition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Direct acquisition. 908.7101-3 Section 908.7101-3 Federal Acquisition Regulations System DEPARTMENT OF ENERGY COMPETITION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition of Special Items 908.7101-3 Direct...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false [Reserved] 7.300 Section 7.300 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING ACQUISITION PLANNING Contractor Versus Government Performance 7.300 [Reserved] ...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Authority. 1601.102 Section 1601.102 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
48 CFR 1601.103 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Applicability. 1601.103 Section 1601.103 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
48 CFR 1601.103 - Applicability.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Applicability. 1601.103 Section 1601.103 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
48 CFR 1601.103 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Applicability. 1601.103 Section 1601.103 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
48 CFR 1601.103 - Applicability.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Applicability. 1601.103 Section 1601.103 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Authority. 1601.102 Section 1601.102 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Authority. 1601.102 Section 1601.102 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Authority. 1601.102 Section 1601.102 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
48 CFR 1601.103 - Applicability.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Applicability. 1601.103 Section 1601.103 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Policy. 2001.301 Section 2001.301 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION GENERAL NUCLEAR REGULATORY COMMISSION ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2001.301 Policy. Policy...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Policy. 2001.301 Section 2001.301 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION GENERAL NUCLEAR REGULATORY COMMISSION ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2001.301 Policy. Policy...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Policy. 2001.301 Section 2001.301 Federal Acquisition Regulations System NUCLEAR REGULATORY COMMISSION GENERAL NUCLEAR REGULATORY COMMISSION ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2001.301 Policy. Policy...
48 CFR 208.7001 - Definitions.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Program. Integrated materiel management means assignment of acquisition management responsibility to one... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Definitions. 208.7001 Section 208.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT...
48 CFR 208.7001 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Program. Integrated materiel management means assignment of acquisition management responsibility to one... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Definitions. 208.7001 Section 208.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT...
48 CFR 208.7001 - Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Program. Integrated materiel management means assignment of acquisition management responsibility to one... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Definitions. 208.7001 Section 208.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT...
48 CFR 208.7001 - Definitions.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Program. Integrated materiel management means assignment of acquisition management responsibility to one... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Definitions. 208.7001 Section 208.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT...
48 CFR 208.7001 - Definitions.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Program. Integrated materiel management means assignment of acquisition management responsibility to one... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Definitions. 208.7001 Section 208.7001 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Issuance. 3401.104 Section 3401.104 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Purpose, Authority, Issuance 3401.104 Issuance. ...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false General. 3401.601 Section 3401.601 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Contracting Authority and Responsibilities 3401.601 General...
Blueprint for Acquisition Reform, Version 3.0
2008-07-01
represents a substantial and immediate step forward in establishing the Coast Guard as a model mid-sized federal agency for acquisition processes...Blueprint for Acquisition Reform in the U. S. Coast Guard “The Coast Guard must become the model for mid-sized Federal agency acquisition in process...acquisition (DoD 5000 model >CG Major Systems Acquisition Manual) • Deepwater Program Executive Officer (PEO): System of Systems performance-based
DOE Office of Scientific and Technical Information (OSTI.GOV)
WHITE, D.A.
1999-12-29
This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS).
48 CFR 215.407-5 - Estimating systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...
48 CFR 215.407-5 - Estimating systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...
48 CFR 215.407-5 - Estimating systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...
48 CFR 215.407-5 - Estimating systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...
48 CFR 215.407-5 - Estimating systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Estimating systems. 215.407-5 Section 215.407-5 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM....407-5 Estimating systems. ...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-19
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Parts 212 and 252 RIN 0750-AH27 Defense Federal Acquisition Regulation Supplement; Pilot Program for Acquisition of Military-Purpose Nondevelopmental Items (DFARS Case 2011-D034) AGENCY: Defense Acquisition Regulations System...
48 CFR 225.7003 - Restrictions on acquisition of specialty metals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Restrictions on acquisition of specialty metals. 225.7003 Section 225.7003 Federal Acquisition Regulations System DEFENSE... Restrictions on acquisition of specialty metals. ...
48 CFR 225.7003 - Restrictions on acquisition of specialty metals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Restrictions on acquisition of specialty metals. 225.7003 Section 225.7003 Federal Acquisition Regulations System DEFENSE... Restrictions on acquisition of specialty metals. ...
48 CFR 1807.7201 - Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Definitions. 1807.7201 Section 1807.7201 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND SPACE ADMINISTRATION COMPETITION AND ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Forecasting 1807.7201 Definitions. Class...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false [Reserved] 13.304 Section 13.304 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION PROCEDURES Simplified Acquisition Methods 13.304 [Reserved] ...
Two Demonstrations with a New Data-Acquisition System
ERIC Educational Resources Information Center
Kraftmakher, Yaakov
2014-01-01
Nowadays, the use of data-acquisition systems in undergraduate laboratories is routine. Many computer-assisted experiments became possible with the PASCO scientific data-acquisition system based on the 750 Interface and DataStudio software. A new data-acquisition system developed by PASCO includes the 850 Universal Interface and Capstone software.…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-25
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Parts 219 and 252 [DFARS Case... System AGENCY: Defense Acquisition Regulations System, Department of Defense (DoD). ACTION: Interim rule... Supplement (DFARS) to conform to the Federal Acquisition Regulation (FAR) by providing Department of Defense...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Issuance. 1601.104 Section 1601.104 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Issuance. 1601.104 Section 1601.104 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Issuance. 1601.104 Section 1601.104 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Authority. 1601.102 Section 1601.102 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Issuance. 1601.104 Section 1601.104 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Issuance. 1601.104 Section 1601.104 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH BENEFITS ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Policy. 241.201 Section 241.201 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SPECIAL CATEGORIES OF CONTRACTING ACQUISITION OF UTILITY SERVICES Acquiring Utility Services 241...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Policy. 2401.301 Section 2401.301 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2401.301 Policy. (a)(1...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Policy. 2401.301 Section 2401.301 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2401.301 Policy. (a)(1...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Policy. 2401.301 Section 2401.301 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT GENERAL FEDERAL ACQUISITION REGULATION SYSTEM Agency Acquisition Regulations 2401.301 Policy. (a)(1...
48 CFR 1.403 - Individual deviations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...
48 CFR 1.403 - Individual deviations.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...
48 CFR 1.403 - Individual deviations.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Individual deviations. 1.403 Section 1.403 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.403 Individual deviations. Individual...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Exceptions. 225.7603 Section 225.7603 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7603...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Procedures. 225.7602 Section 225.7602 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7602...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Procedures. 225.7602 Section 225.7602 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7602...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Procedures. 225.7602 Section 225.7602 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7602...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Exceptions. 225.7603 Section 225.7603 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7603...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Exceptions. 225.7603 Section 225.7603 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7603...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Exceptions. 225.7603 Section 225.7603 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7603...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Procedures. 225.7602 Section 225.7602 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7602...
48 CFR 3401.403 - Individual deviations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Individual deviations. 3401.403 Section 3401.403 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Deviations 3401.403 Individual deviations. An individual...
48 CFR 3401.103 - Applicability.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Applicability. 3401.103 Section 3401.103 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION GENERAL ED ACQUISITION REGULATION SYSTEM Purpose, Authority, Issuance 3401.103 Applicability. The FAR and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Exceptions. 225.7603 Section 225.7603 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7603...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Procedures. 225.7602 Section 225.7602 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7602...
48 CFR 13.005 - Federal Acquisition Streamlining Act of 1994 list of inapplicable laws.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Federal Acquisition Streamlining Act of 1994 list of inapplicable laws. 13.005 Section 13.005 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-19
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Part 213 RIN 0750-AH07 Defense Federal Acquisition Regulation Supplement; Ships Bunkers Easy Acquisition (SEA) Card[supreg] and Aircraft Ground Services (DFARS Case 2009-D019) AGENCY: Defense Acquisition Regulations System, Department of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-20
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Part 213 RIN 0750-AH07 Defense Federal Acquisition Regulation Supplement; Ships Bunkers Easy Acquisition (SEA) Card[supreg] and Aircraft Ground Services (DFARS Case 2009-D019) AGENCY: Defense Acquisition Regulations System, Department of...
48 CFR 13.005 - Federal Acquisition Streamlining Act of 1994 list of inapplicable laws.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Federal Acquisition Streamlining Act of 1994 list of inapplicable laws. 13.005 Section 13.005 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION...
48 CFR 13.005 - Federal Acquisition Streamlining Act of 1994 list of inapplicable laws.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Federal Acquisition Streamlining Act of 1994 list of inapplicable laws. 13.005 Section 13.005 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION...
48 CFR 13.005 - Federal Acquisition Streamlining Act of 1994 list of inapplicable laws.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Federal Acquisition Streamlining Act of 1994 list of inapplicable laws. 13.005 Section 13.005 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION...
48 CFR 1.102-3 - Acquisition team.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining the Federal Acquisition Team (Team) in the Guiding Principles is to ensure that participants in the...
48 CFR 1.102-3 - Acquisition team.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining the Federal Acquisition Team (Team) in the Guiding Principles is to ensure that participants in the...
48 CFR 1.102-3 - Acquisition team.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining the Federal Acquisition Team (Team) in the Guiding Principles is to ensure that participants in the...
48 CFR 1.102-3 - Acquisition team.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining the Federal Acquisition Team (Team) in the Guiding Principles is to ensure that participants in the...
48 CFR 1.102-3 - Acquisition team.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition team. 1.102-3... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102-3 Acquisition team. The purpose of defining the Federal Acquisition Team (Team) in the Guiding Principles is to ensure that participants in the...
48 CFR 3409.570 - Certification at or below the simplified acquisition threshold.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 7 2014-10-01 2014-10-01 false Certification at or below the simplified acquisition threshold. 3409.570 Section 3409.570 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION COMPETITION AND ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS Organizational and Consultant...
48 CFR 3409.570 - Certification at or below the simplified acquisition threshold.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 7 2011-10-01 2011-10-01 false Certification at or below the simplified acquisition threshold. 3409.570 Section 3409.570 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION COMPETITION AND ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS Organizational and Consultant...
48 CFR 3409.570 - Certification at or below the simplified acquisition threshold.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 7 2012-10-01 2012-10-01 false Certification at or below the simplified acquisition threshold. 3409.570 Section 3409.570 Federal Acquisition Regulations System DEPARTMENT OF EDUCATION ACQUISITION REGULATION COMPETITION AND ACQUISITION PLANNING CONTRACTOR QUALIFICATIONS Organizational and Consultant...
Data Acquisition for Modular Biometric Monitoring System
NASA Technical Reports Server (NTRS)
Grodsinsky, Carlos M. (Inventor); Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor)
2014-01-01
A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.
48 CFR 13.302 - Purchase orders.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Purchase orders. 13.302 Section 13.302 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES SIMPLIFIED ACQUISITION PROCEDURES Simplified Acquisition Methods 13.302 Purchase...
48 CFR 18.119 - Trade agreements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Trade agreements. 18.119 Section 18.119 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES EMERGENCY ACQUISITIONS Available Acquisition Flexibilities 18.119 Trade agreements...
76 FR 27274 - Defense Federal Acquisition Regulation Supplement; Technical Amendments
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-11
... DEPARTMENT OF DEFENSE Defense Acquisition Regulations System 48 CFR Part 225 Defense Federal Acquisition Regulation Supplement; Technical Amendments AGENCY: Defense Acquisition Regulations System... Federal Acquisition Regulation Supplement (DFARS) to direct contracting officers to additional guidance on...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Policy. 2407.102 Section 2407.102 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT COMPETITION AND ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Plans 2407.102 Policy. The Senior...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Policy. 2407.102 Section 2407.102 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT COMPETITION AND ACQUISITION PLANNING ACQUISITION PLANNING Acquisition Plans 2407.102 Policy. The Senior...
48 CFR 18.119 - Trade agreements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Trade agreements. 18.119 Section 18.119 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES EMERGENCY ACQUISITIONS Available Acquisition Flexibilities 18.119 Trade agreements...
48 CFR 18.118 - Trade agreements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Trade agreements. 18.118 Section 18.118 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES EMERGENCY ACQUISITIONS Available Acquisition Flexibilities 18.118 Trade agreements...
48 CFR 18.119 - Trade agreements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Trade agreements. 18.119 Section 18.119 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION CONTRACTING METHODS AND CONTRACT TYPES EMERGENCY ACQUISITIONS Available Acquisition Flexibilities 18.119 Trade agreements...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Payments. 8.709 Section 8.709 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false General. 8.702 Section 8.702 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Prices. 8.707 Section 8.707 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Procedures. 8.705 Section 8.705 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION ACQUISITION PLANNING REQUIRED SOURCES OF SUPPLIES AND SERVICES Acquisition From Nonprofit Agencies Employing People Who Are...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Purpose. 1601.101 Section 1601.101 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH... Employees Health Benefits Acquisition Regulation, within title 48, the Federal Acquisition Regulation System...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Purpose. 1601.101 Section 1601.101 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH... Employees Health Benefits Acquisition Regulation, within title 48, the Federal Acquisition Regulation System...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Purpose. 1601.101 Section 1601.101 Federal Acquisition Regulations System OFFICE OF PERSONNEL MANAGEMENT FEDERAL EMPLOYEES HEALTH... Employees Health Benefits Acquisition Regulation, within title 48, the Federal Acquisition Regulation System...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 7 2013-10-01 2012-10-01 true Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 7 2014-10-01 2014-10-01 false Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 7 2012-10-01 2012-10-01 false Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
48 CFR 225.1103 - Other provisions and clauses.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Other provisions and clauses. 225.1103 Section 225.1103 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Solicitation Provisions and...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Definition. 1.401 Section 1.401 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Deviations from the FAR 1.401 Definition. Deviation means any one or...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Purpose. 2801.101 Section 2801.101 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE General DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 2801.101 Purpose. (a) The Justice Acquisition...
Code of Federal Regulations, 2010 CFR
2004-10-01
... 48 Federal Acquisition Regulations System 7 2004-10-01 2004-10-01 false Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 7 2011-10-01 2011-10-01 false Content. 3001.7001 Section 3001.7001 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Other Determinations, Waivers, Exceptions, Approvals, Reviews, and...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 6 2011-10-01 2011-10-01 false Purpose. 2801.101 Section 2801.101 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE GENERAL DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 2801.101 Purpose. (a) The Justice Acquisition...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 6 2012-10-01 2012-10-01 false Purpose. 2801.101 Section 2801.101 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE GENERAL DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 2801.101 Purpose. (a) The Justice Acquisition...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 6 2013-10-01 2013-10-01 false Purpose. 2801.101 Section 2801.101 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE GENERAL DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 2801.101 Purpose. (a) The Justice Acquisition...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 6 2014-10-01 2014-10-01 false Purpose. 2801.101 Section 2801.101 Federal Acquisition Regulations System DEPARTMENT OF JUSTICE GENERAL DEPARTMENT OF JUSTICE ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 2801.101 Purpose. (a) The Justice Acquisition...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Termination. 1.603-4 Section 1.603-4 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Career Development, Contracting Authority, and Responsibilities 1.603-4...
48 CFR 1.502 - Unsolicited proposed revisions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Unsolicited proposed revisions. 1.502 Section 1.502 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Agency and Public Participation 1.502 Unsolicited proposed...
48 CFR 1301.303 - Publication and codification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Publication and codification. 1301.303 Section 1301.303 Federal Acquisition Regulations System DEPARTMENT OF COMMERCE GENERAL DEPARTMENT OF COMMERCE ACQUISITION REGULATIONS SYSTEM Agency Acquisition Regulations 1301.303 Publication and...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Waivers. 225.7604 Section 225.7604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7604 Waivers. The...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Waivers. 225.7604 Section 225.7604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7604 Waivers. The...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Waivers. 225.7604 Section 225.7604 Federal Acquisition Regulations System DEFENSE ACQUISITION REGULATIONS SYSTEM, DEPARTMENT OF DEFENSE SOCIOECONOMIC PROGRAMS FOREIGN ACQUISITION Secondary Arab Boycott of Israel 225.7604 Waivers. The...