Science.gov

Sample records for acquisition system developed

  1. Development of Data Acquisition System for Consolidated Undrained Triaxial Test

    NASA Astrophysics Data System (ADS)

    Lee, L. M.; Yasuo, T.; Wei, L. C.; Yuan, L. C.

    2016-07-01

    Consolidated Undrained (CU) triaxial test is a common laboratory test used in practice for determining effective and total shear strength parameters of soil. This paper reported works carried out to develop a data acquisition system for a self-assembled triaxial machine. The developed system was capable of acquiring signals from the installed sensors (i.e. pressure transducer, load cell, LVDT), interpreting and presenting the data in real-time graphs. In addition, the study highlighted the advantages of performing double vacuuming method to saturate the soil specimen. The saturation can be obtained quicker and at a significantly lower cell pressure compared to the conventional stepwise increment of back pressure and cell pressure method.

  2. Development of a PC-based data acquisition and control system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An inexpensive data acquisition and control system was developed, which can easily be used with different computers for many agricultural and biological applications. The high-speed data acquisition and control device uses only an RS-232 serial port to interface with a PC. The device has two analo...

  3. Systematic methods for knowledge acquisition and expert system development

    NASA Technical Reports Server (NTRS)

    Belkin, Brenda L.; Stengel, Robert F.

    1991-01-01

    Nine cooperating rule-based systems, collectively called AUTOCREW, were designed to automate functions and decisions associated with a combat aircraft's subsystem. The organization of tasks within each system is described; performance metrics were developed to evaluate the workload of each rule base, and to assess the cooperation between the rule-bases. Each AUTOCREW subsystem is composed of several expert systems that perform specific tasks. AUTOCREW's NAVIGATOR was analyzed in detail to understand the difficulties involved in designing the system and to identify tools and methodologies that ease development. The NAVIGATOR determines optimal navigation strategies from a set of available sensors. A Navigation Sensor Management (NSM) expert system was systematically designed from Kalman filter covariance data; four ground-based, a satellite-based, and two on-board INS-aiding sensors were modeled and simulated to aid an INS. The NSM Expert was developed using the Analysis of Variance (ANOVA) and the ID3 algorithm. Navigation strategy selection is based on an RSS position error decision metric, which is computed from the covariance data. Results show that the NSM Expert predicts position error correctly between 45 and 100 percent of the time for a specified navaid configuration and aircraft trajectory. The NSM Expert adapts to new situations, and provides reasonable estimates of hybrid performance. The systematic nature of the ANOVA/ID3 method makes it broadly applicable to expert system design when experimental or simulation data is available.

  4. Systematic methods for knowledge acquisition and expert system development

    NASA Technical Reports Server (NTRS)

    Belkin, Brenda L.; Stengel, Robert F.

    1991-01-01

    Nine cooperating rule-based systems, collectively called AUTOCREW which were designed to automate functions and decisions associated with a combat aircraft's subsystems, are discussed. The organization of tasks within each system is described; performance metrics were developed to evaluate the workload of each rule base and to assess the cooperation between the rule bases. Simulation and comparative workload results for two mission scenarios are given. The scenarios are inbound surface-to-air-missile attack on the aircraft and pilot incapacitation. The methodology used to develop the AUTOCREW knowledge bases is summarized. Issues involved in designing the navigation sensor selection expert in AUTOCREW's NAVIGATOR knowledge base are discussed in detail. The performance of seven navigation systems aiding a medium-accuracy INS was investigated using Kalman filter covariance analyses. A navigation sensor management (NSM) expert system was formulated from covariance simulation data using the analysis of variance (ANOVA) method and the ID3 algorithm. ANOVA results show that statistically different position accuracies are obtained when different navaids are used, the number of navaids aiding the INS is varied, the aircraft's trajectory is varied, and the performance history is varied. The ID3 algorithm determines the NSM expert's classification rules in the form of decision trees. The performance of these decision trees was assessed on two arbitrary trajectories, and the results demonstrate that the NSM expert adapts to new situations and provides reasonable estimates of the expected hybrid performance.

  5. Data Acquisition Systems

    NASA Technical Reports Server (NTRS)

    1989-01-01

    Technology developed during a joint research program with Langley and Kinetic Systems Corporation led to Kinetic Systems' production of a high speed Computer Automated Measurement and Control (CAMAC) data acquisition system. The study, which involved the use of CAMAC equipment applied to flight simulation, significantly improved the company's technical capability and produced new applications. With Digital Equipment Corporation, Kinetic Systems is marketing the system to government and private companies for flight simulation, fusion research, turbine testing, steelmaking, etc.

  6. Development of an optical beam system for deep sea data acquisition

    SciTech Connect

    Shibata, Yozo

    1994-12-31

    Remotely Operated Vehicles (ROV) are an ideal method for acquiring data from instruments located on the seabed. Electrical, acoustic or optical signals can be used to communicate with the data acquisition system. While optical signals have high capacity, the power of the optical beam decreases rapidly with distance in sea water; however, the ROV`s ability to approach the instruments eliminates this problem. To investigate a feasibility of an optical beam system for underwater data acquisition, the author has developed and manufactured a prototype data acquisition instrument which the ROV can control. Based on the communication test results, he concludes that such a system is a practical means of short-range underwater data acquisition.

  7. Development of a data acquisition and processing system for precision agriculture

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A data acquisition and processing system for precision agriculture was developed by using MapX5.0 and Visual C 6.0. This system can be used easily and quickly for drawing grid maps in-field, creating parameters for grid-reorganization, guiding in-field data collection, converting data between diffe...

  8. Development of a data acquisition and processing system for precision agriculture

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A data acquisition and processing system for precision agriculture was developed by using MapX5.0 and Visual C6.0. This system can be used easily and quickly for drawing grid maps in-field, making out parameters for grid-reorganization, guiding for in-field data collection, converting data between ...

  9. New online signature acquisition system

    NASA Astrophysics Data System (ADS)

    Oulefki, Adel; Mostefai, Messaoud; Abbadi, Belkacem; Djebrani, Samira; Bouziane, Abderraouf; Chahir, Youssef

    2013-01-01

    We present a nonconstraining and low-cost online signature acquisition system that has been developed to enhance the performances of an existing multimodal biometric authentication system (based initially on both voice and image modalities). A laboratory prototype has been developed and validated for an online signature acquisition.

  10. Development of an Integrated Data Acquisition System for a Small Flight Probe

    NASA Technical Reports Server (NTRS)

    Swanson, Gregory T.; Empey, Daniel M.; Skokova, Kristina A.; Venkatapathy, Ethiraj

    2012-01-01

    In support of the SPRITE concept, an integrated data acquisition system has been developed and fabricated for preliminary testing. The data acquisition system has been designed to condition traditional thermal protection system sensors, store their data to an on-board memory card, and in parallel, telemeter to an external system. In the fall of 2010, this system was integrated into a 14 in. diameter, 45 degree sphere cone probe instrumented with thermal protection system sensors. This system was then tested at the NASA Ames Research Center Aerodynamic Heating Facility's arc jet at approximately 170 W/sq. cm. The first test in December 2010 highlighted hardware design issues that were redesigned and implemented leading to a successful test in February 2011.

  11. Advanced Data Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Perotti, J.

    2003-01-01

    Current and future requirements of the aerospace sensors and transducers field make it necessary for the design and development of new data acquisition devices and instrumentation systems. New designs are sought to incorporate self-health, self-calibrating, self-repair capabilities, allowing greater measurement reliability and extended calibration cycles. With the addition of power management schemes, state-of-the-art data acquisition systems allow data to be processed and presented to the users with increased efficiency and accuracy. The design architecture presented in this paper displays an innovative approach to data acquisition systems. The design incorporates: electronic health self-check, device/system self-calibration, electronics and function self-repair, failure detection and prediction, and power management (reduced power consumption). These requirements are driven by the aerospace industry need to reduce operations and maintenance costs, to accelerate processing time and to provide reliable hardware with minimum costs. The project's design architecture incorporates some commercially available components identified during the market research investigation like: Field Programmable Gate Arrays (FPGA) Programmable Analog Integrated Circuits (PAC IC) and Field Programmable Analog Arrays (FPAA); Digital Signal Processing (DSP) electronic/system control and investigation of specific characteristics found in technologies like: Electronic Component Mean Time Between Failure (MTBF); and Radiation Hardened Component Availability. There are three main sections discussed in the design architecture presented in this document. They are the following: (a) Analog Signal Module Section, (b) Digital Signal/Control Module Section and (c) Power Management Module Section. These sections are discussed in detail in the following pages. This approach to data acquisition systems has resulted in the assignment of patent rights to Kennedy Space Center under U.S. patent # 6

  12. A portable data acquisition and control system for waste treatment development

    SciTech Connect

    Bowers, J; Rogers, H

    1999-06-07

    Lawrence Livermore National Laboratory (LLNL) has developed a Portable Data Acquisition and Control (PDAC) System that is basically a laboratory-scale Program Logic Control (PLC). This system can obtain signals from numerous sensors (e.g., pH, level, pressure, and flow meters), open and close valves, and turn on and off pumps. The data can then be saved on a spreadsheet or displayed as a graph/indicator in real-time on a computer screen.

  13. Hardware and Software Developments for the Accurate Time-Linked Data Acquisition System

    SciTech Connect

    BERG,DALE E.; RUMSEY,MARK A.; ZAYAS,JOSE R.

    1999-11-09

    Wind-energy researchers at Sandia National Laboratories have developed a new, light-weight, modular data acquisition system capable of acquiring long-term, continuous, multi-channel time-series data from operating wind-turbines. New hardware features have been added to this system to make it more flexible and permit programming via telemetry. User-friendly Windows-based software has been developed for programming the hardware and acquiring, storing, analyzing, and archiving the data. This paper briefly reviews the major components of the system, summarizes the recent hardware enhancements and operating experiences, and discusses the features and capabilities of the software programs that have been developed.

  14. Data-acquisition systems

    SciTech Connect

    Cyborski, D.R.; Teh, K.M.

    1995-08-01

    Up to now, DAPHNE, the data-acquisition system developed for ATLAS, was used routinely for experiments at ATLAS and the Dynamitron. More recently, the Division implemented 2 MSU/DAPHNE systems. The MSU/DAPHNE system is a hybrid data-acquisition system which combines the front-end of the Michigan State University (MSU) DA system with the traditional DAPHNE back-end. The MSU front-end is based on commercially available modules. This alleviates the problems encountered with the DAPHNE front-end which is based on custom designed electronics. The first MSU system was obtained for the APEX experiment and was used there successfully. A second MSU front-end, purchased as a backup for the APEX experiment, was installed as a fully-independent second MSU/DAPHNE system with the procurement of a DEC 3000 Alpha host computer, and was used successfully for data-taking in an experiment at ATLAS. Additional hardware for a third system was bought and will be installed. With the availability of 2 MSU/DAPHNE systems in addition to the existing APEX setup, it is planned that the existing DAPHNE front-end will be decommissioned.

  15. Development of small and inexpensive digital data acquisition systems using a microcontroller-based approach.

    PubMed

    Naivar, Mark A; Wilder, Mark E; Habbersett, Robert C; Woods, Travis A; Sebba, David S; Nolan, John P; Graves, Steven W

    2009-12-01

    Fully digital data acquisition systems for use in flow cytometry provide excellent flexibility and precision. Here, we demonstrate the development of a low cost, small, and low power digital flow cytometry data acquisition system using a single microcontroller chip with an integrated analog to digital converter (ADC). Our demonstration system uses a commercially available evaluation board making the system simple to integrate into a flow cytometer. We have evaluated this system using calibration microspheres analyzed on commercial, slow-flow, and CCD-based flow cytometers. In our evaluations, our demonstration data system clearly resolves all eight peaks of a Rainbow microsphere set on both a slow-flow flow cytometer and a retrofitted BD FACScalibur, which indicates it has the sensitivity and resolution required for most flow cytometry applications. It is also capable of millisecond time resolution, full waveform collection, and selective triggering of data collection from a CCD camera. The capability of our demonstration system suggests that the use of microcontrollers for flow cytometry digital data-acquisition will be increasingly valuable for extending the life of older cytometers and provides a compelling data-system design approach for low-cost, portable flow cytometers. PMID:19852060

  16. Development of a simple, self-contained flight test data acquisition system

    NASA Technical Reports Server (NTRS)

    Renz, R. R. L.

    1981-01-01

    A low cost flight test data acquisition system, applicable to general aviation airplanes, was developed which meets criteria for doing longitudinal and lateral stability analysis. Th package consists of (1) a microprocessor controller and data acquisition module; (2) a transducer module; and (3) a power supply module. The system is easy to install and occupies space in the cabin or baggage compartment of the airplane. All transducers are contained in these modules except the total pressure tube, static pressure air temperature transducer, and control position transducers. The NASA-developed MMLE program was placed on a microcomputer on which all data reduction is done. The flight testing program undertaken proved both the flight testing hardware and the data reduction method to be applicable to the current field of general aviation airplanes.

  17. MDSplus data acquisition system

    SciTech Connect

    Stillerman, J.A.; Fredian, T.W.; Klare, K.; Manduchi, G.

    1997-01-01

    MDSplus, a tree based, distributed data acquisition system, was developed in collaboration with the ZTH Group at Los Alamos National Lab and the RFX Group at CNR in Padua, Italy. It is currently in use at MIT, RFX in Padua, TCV at EPFL in Lausanne, and KBSI in South Korea. MDSplus is made up of a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. It is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. While usually used over a Local Area Network, these tools can be used over the Internet to provide access for remote diagnosticians and even machine operators. An interface to a relational database is provided for storage and management of processed data. IDL is used as the primary data analysis and visualization tool. IDL is a registered trademark of Research Systems Inc. {copyright} {ital 1996 American Institute of Physics.}

  18. Development of the Data Acquisition and Processing System for a Pulsed 2-Micron Coherent Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, Jeffrey Y.; Koch, Grady J.; Kavaya, Michael J.

    2010-01-01

    A general overview of the development of a data acquisition and processing system is presented for a pulsed, 2-micron coherent Doppler Lidar system located in NASA Langley Research Center in Hampton, Virginia, USA. It is a comprehensive system that performs high-speed data acquisition, analysis, and data display both in real time and offline. The first flight missions are scheduled for the summer of 2010 as part of the NASA Genesis and Rapid Intensification Processes (GRIP) campaign for the study of hurricanes. The system as well as the control software is reviewed and its requirements and unique features are discussed.

  19. Portable data acquisition system

    SciTech Connect

    Bowers, J; Rogers, H

    1999-05-03

    Lawrence Livermore National Laboratory (LLNL) has developed a Portable Data Acquisition (DAQ) System that is basically a laboratory-scale of Program Logic Control (PLC). This DAQ system can obtain signals from numerous sensors (e.g., pH, level, pressure, flow meters), open and close valves, and turn on and off pumps. The data can then be saved on a spreadsheet or displayed as a graph/indicator in real-time on a computer screen. The whole DAQ system was designed to be portable so that it could sit on a bench top during laboratory-scale treatability studies, or moved out into the field during larger studies. This DAQ system is also fairly simple to use. All that is required is some working knowledge of LabVIEW 4.1, and how to properly wire the process equipment. The DAQ system has been used during treatability studies on cesium precipitation, controlled hydrolysis of water- reactive wastes, and other waste treatment studies that enable LLNL to comply with the Federal Facility Compliance Act (FFCAct). Improved data acquisition allows the study to be better monitored, and therefore better controlled, and can be used to determine the results of the treatment study more effectively. This also contributes to the design of larger treatment processes.

  20. Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

    NASA Astrophysics Data System (ADS)

    Rahman, Nur Aira Abd; Yussup, Nolida; Abdullah, Jaafar B.; Ibrahim, Maslina Bt. Mohd; Abdullah, Nor Arymaswati; Mokhtar, Mukhlis B.; Hassan, Hearie B.

    2015-04-01

    A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

  1. Development of Labview based data acquisition and multichannel analyzer software for radioactive particle tracking system

    SciTech Connect

    Rahman, Nur Aira Abd Yussup, Nolida; Ibrahim, Maslina Bt. Mohd; Abdullah, Nor Arymaswati; Mokhtar, Mukhlis B.; Abdullah, Jaafar B.; Hassan, Hearie B.

    2015-04-29

    A DAQ (data acquisition) software called RPTv2.0 has been developed for Radioactive Particle Tracking System in Malaysian Nuclear Agency. RPTv2.0 that features scanning control GUI, data acquisition from 12-channel counter via RS-232 interface, and multichannel analyzer (MCA). This software is fully developed on National Instruments Labview 8.6 platform. Ludlum Model 4612 Counter is used to count the signals from the scintillation detectors while a host computer is used to send control parameters, acquire and display data, and compute results. Each detector channel consists of independent high voltage control, threshold or sensitivity value and window settings. The counter is configured with a host board and twelve slave boards. The host board collects the counts from each slave board and communicates with the computer via RS-232 data interface.

  2. Development of a light-weight, wind-turbine-rotor-based data acquisition system

    SciTech Connect

    Berg, D.E.; Rumsey, M.; Robertson, P.; Kelley, N.; McKenna, E.; Gass, K.

    1997-12-01

    Wind-energy researchers at Sandia National Laboratories (SNL) and the National Renewable Energy Laboratory (NREL) are developing a new, light-weight, modular system capable of acquiring long-term, continuous time-series data from current-generation small or large, dynamic wind-turbine rotors. Meetings with wind-turbine research personnel at NREL and SNL resulted in a list of the major requirements that the system must meet. Initial attempts to locate a commercial system that could meet all of these requirements were not successful, but some commercially available data acquisition and radio/modem subsystems that met many of the requirements were identified. A time synchronization subsystem and a programmable logic device subsystem to integrate the functions of the data acquisition, the radio/modem, and the time synchronization subsystems and to communicate with the user have been developed at SNL. This paper presents the data system requirements, describes the four major subsystems comprising the system, summarizes the current status of the system, and presents the current plans for near-term development of hardware and software.

  3. Data acquisition system

    DOEpatents

    Shapiro, Stephen L.; Mani, Sudhindra; Atlas, Eugene L.; Cords, Dieter H. W.; Holbrook, Britt

    1997-01-01

    A data acquisition circuit for a particle detection system that allows for time tagging of particles detected by the system. The particle detection system screens out background noise and discriminate between hits from scattered and unscattered particles. The detection system can also be adapted to detect a wide variety of particle types. The detection system utilizes a particle detection pixel array, each pixel containing a back-biased PIN diode, and a data acquisition pixel array. Each pixel in the particle detection pixel array is in electrical contact with a pixel in the data acquisition pixel array. In response to a particle hit, the affected PIN diodes generate a current, which is detected by the corresponding data acquisition pixels. This current is integrated to produce a voltage across a capacitor, the voltage being related to the amount of energy deposited in the pixel by the particle. The current is also used to trigger a read of the pixel hit by the particle.

  4. Software Development for a CompactRIO-Based Wire Scanner Control and Data Acquisition SYstem

    SciTech Connect

    Sedillo, James Daniel

    2012-05-16

    The Beam Diagnostics and Instrumentation Team at the Los Alamos Neutron Science Center is developing a wire scanner data acquisition and control system with a National Instrument's compactRIO at its core. For this application, the compactRIO controller not only requires programming the FPGA and RT computer internal to the compactRIO, but also requires programming a client computer and a touch panel display. This article will summarize the hardware interfaces and describe the software design approach utilized for programming and interfacing the four systems together in order to fulfill the design requirements and promote reliable interoperability.

  5. Development of an MR-compatible SPECT system (MRSPECT) for simultaneous data acquisition

    NASA Astrophysics Data System (ADS)

    Hamamura, Mark J.; Ha, Seunghoon; Roeck, Werner W.; Tugan Muftuler, L.; Wagenaar, Douglas J.; Meier, Dirk; Patt, Bradley E.; Nalcioglu, Orhan

    2010-03-01

    In medical imaging, single-photon emission computed tomography (SPECT) can provide specific functional information while magnetic resonance imaging (MRI) can provide high spatial resolution anatomical information as well as complementary functional information. In this study, we developed a miniaturized dual-modality SPECT/MRI (MRSPECT) system and demonstrated the feasibility of simultaneous SPECT and MRI data acquisition, with the possibility of whole-body MRSPECT systems through suitable scaling of components. For our MRSPECT system, a cadmium-zinc-telluride (CZT) nuclear radiation detector was interfaced with a specialized radiofrequency (RF) coil and placed within a whole-body 4 T MRI system. Various phantom experiments characterized the interaction between the SPECT and MRI hardware components. The metallic components of the SPECT hardware altered the B0 field and generated a non-uniform reduction in the signal-to-noise ratio (SNR) of the MR images. The presence of a magnetic field generated a position shift and resolution loss in the nuclear projection data. Various techniques were proposed to compensate for these adverse effects. Overall, our results demonstrate that accurate, simultaneous SPECT and MRI data acquisition is feasible, justifying the further development of MRSPECT for either small-animal imaging or whole-body human systems by using appropriate components.

  6. NASA Data Acquisition System Software Development for Rocket Propulsion Test Facilities

    NASA Technical Reports Server (NTRS)

    Herbert, Phillip W., Sr.; Elliot, Alex C.; Graves, Andrew R.

    2015-01-01

    Current NASA propulsion test facilities include Stennis Space Center in Mississippi, Marshall Space Flight Center in Alabama, Plum Brook Station in Ohio, and White Sands Test Facility in New Mexico. Within and across these centers, a diverse set of data acquisition systems exist with different hardware and software platforms. The NASA Data Acquisition System (NDAS) is a software suite designed to operate and control many critical aspects of rocket engine testing. The software suite combines real-time data visualization, data recording to a variety formats, short-term and long-term acquisition system calibration capabilities, test stand configuration control, and a variety of data post-processing capabilities. Additionally, data stream conversion functions exist to translate test facility data streams to and from downstream systems, including engine customer systems. The primary design goals for NDAS are flexibility, extensibility, and modularity. Providing a common user interface for a variety of hardware platforms helps drive consistency and error reduction during testing. In addition, with an understanding that test facilities have different requirements and setups, the software is designed to be modular. One engine program may require real-time displays and data recording; others may require more complex data stream conversion, measurement filtering, or test stand configuration management. The NDAS suite allows test facilities to choose which components to use based on their specific needs. The NDAS code is primarily written in LabVIEW, a graphical, data-flow driven language. Although LabVIEW is a general-purpose programming language; large-scale software development in the language is relatively rare compared to more commonly used languages. The NDAS software suite also makes extensive use of a new, advanced development framework called the Actor Framework. The Actor Framework provides a level of code reuse and extensibility that has previously been difficult

  7. "Data Acquisition Systems"

    SciTech Connect

    Unterweger, Michael; Costrell, Louis deceased

    2009-07-07

    This project involved support for Lou Costrell and myself in the development of IEEE and IEC standards for nuclear counting and data acquisition systems. Over the years, as a result of this support, Lou and I were able to attend standards meetings of IEEE and IEC, which led directly to the publication of many standards for NIM systems, FastBus and CAMAC. We also chaired several writing committees as well as ANSI N42 (Nuclear instrumentation), IEEE NIM (NIM standard), IEEE NID (NPSS nuclear instruments and detector) and IEC TC45 WG9 (Nuclear instrumentation). Through this support we were able to assure that the interests of the US and DOE were expressed and implemented in the various standards.

  8. Development and Testing of a Variable Conductance Thermal Acquisition, Transport, and Switching System

    NASA Technical Reports Server (NTRS)

    Bugby, David C.; Farmer, Jeffery T.; Stouffer, Charles J.

    2013-01-01

    This paper describes the development and testing of a scalable thermal management architecture for instruments, subsystems, or systems that must operate in severe space environments with wide variations in sink temperature. The architecture involves a serial linkage of one or more hot-side variable conductance heat pipes (VCHPs) to one or more cold-side loop heat pipes (LHPs). The VCHPs provide wide area heat acquisition, limited distance thermal transport, modest against gravity pumping, concentrated LHP startup heating, and high switching ratio variable conductance operation. The LHPs provide localized heat acquisition, long distance thermal transport, significant against gravity pumping, and high switching ratio variable conductance operation. The single-VCHP, single-LHP system described herein was developed to maintain thermal control of a small robotic lunar lander throughout the lunar day-night thermal cycle. It is also applicable to other variable heat rejection space missions in severe environments. Operationally, despite a 60-70% gas blocked VCHP condenser during ON testing, the system was still able to provide 2-4 W/K ON conductance, 0.01 W/K OFF conductance, and an end-to-end switching ratio of 200-400. The paper provides a detailed analysis of VCHP condenser performance, which quantified the gas blockage situation. Future multi-VCHP/multi-LHP thermal management system concepts that provide power/transport length scalability are also discussed.

  9. Design techniques for developing a computerized instrumentation test plan. [for wind tunnel test data acquisition system

    NASA Technical Reports Server (NTRS)

    Burnett, S. Kay; Forsyth, Theodore J.; Maynard, Everett E.

    1987-01-01

    The development of a computerized instrumentation test plan (ITP) for the NASA/Ames Research Center National Full Scale Aerodynamics Complex (NFAC) is discussed. The objective of the ITP program was to aid the instrumentation engineer in documenting the configuration and calibration of data acquisition systems for a given test at any of four low speed wind tunnel facilities (Outdoor Aerodynamic Research Facility, 7 x 10, 40 x 80, and 80 x 120) at the NFAC. It is noted that automation of the ITP has decreased errors, engineering hours, and setup time while adding a higher level of consistency and traceability.

  10. Development and validation of an improved smartphone heart rate acquisition system

    NASA Astrophysics Data System (ADS)

    Karapetyan, G.; Barseghyan, R.; Sarukhanyan, H.; Agaian, S.

    2015-03-01

    In this paper we propose a robust system for touchless heart rate (HR) acquisition on mobile devices. The application allows monitor heart rate signal during usual mobile device usage such as video watching, games playing, article reading etc. The system is based on algorithm of acquiring heart rate via recording of skin color variations with built-in cameras of mobile device. The signal is acquired from different ROIs of human face, which make it more clear and the amplification of the signal improve the robustness in low lightening conditions. The effectiveness and robustness of the developed system has been demonstrated under different distances from camera source and illumination conditions. The experiments have been done with different mobile devices HRs were collected from 10 subjects, ages 22 to 65, by using the 3 devices. Moreover, we compared the developed method with Food and Drug Administration (FDA) approved sensors and related commercial applications of remote heart rate measurements on mobile devices.

  11. Development of a knowledge acquisition tool for an expert system flight status monitor

    NASA Technical Reports Server (NTRS)

    Disbrow, J. D.; Duke, E. L.; Regenie, V. A.

    1986-01-01

    Two of the main issues in artificial intelligence today are knowledge acquisition and knowledge representation. The Dryden Flight Research Facility of NASA's Ames Research Center is presently involved in the design and implementation of an expert system flight status monitor that will provide expertise and knowledge to aid the flight systems engineer in monitoring today's advanced high-performance aircraft. The flight status monitor can be divided into two sections: the expert system itself and the knowledge acquisition tool. This paper discusses the knowledge acquisition tool, the means it uses to extract knowledge from the domain expert, and how that knowledge is represented for computer use. An actual aircraft system has been codified by this tool with great success. Future real-time use of the expert system has been facilitated by using the knowledge acquisition tool to easily generate a logically consistent and complete knowledge base.

  12. Development of a knowledge acquisition tool for an expert system flight status monitor

    NASA Technical Reports Server (NTRS)

    Disbrow, J. D.; Duke, E. L.; Regenie, V. A.

    1986-01-01

    Two of the main issues in artificial intelligence today are knowledge acquisition dion and knowledge representation. The Dryden Flight Research Facility of NASA's Ames Research Center is presently involved in the design and implementation of an expert system flight status monitor that will provide expertise and knowledge to aid the flight systems engineer in monitoring today's advanced high-performance aircraft. The flight status monitor can be divided into two sections: the expert system itself and the knowledge acquisition tool. The knowledge acquisition tool, the means it uses to extract knowledge from the domain expert, and how that knowledge is represented for computer use is discussed. An actual aircraft system has been codified by this tool with great success. Future real-time use of the expert system has been facilitated by using the knowledge acquisition tool to easily generate a logically consistent and complete knowledge base.

  13. A USB-2 based portable data acquisition system for detector development and nuclear research

    NASA Astrophysics Data System (ADS)

    Jiang, Hao; Ojaruega, M.; Becchetti, F. D.; Griffin, H. C.; Torres-Isea, R. O.

    2011-10-01

    A highly portable high-speed CAMAC data acquisition system has been developed using Kmax software (Sparrow, Inc.) for Macintosh laptop and tower computers. It uses a USB-2 interface to the CAMAC crate controller with custom-written software drivers. Kmax permits 2D parameter gating and specific algorithms have been developed to facilitate the rapid evaluation of various multi-element nuclear detectors for energy and time-of-flight measurements. This includes tests using neutrons from 252Cf and a 2.5 MeV neutron generator as well as standard gamma calibration sources such as 60Co and 137Cs. In addition, the system has been used to measure gamma-gamma coincidences over extended time periods using radioactive sources (e.g., Ra-228, Pa-233, Np-237, and Am-243).

  14. Olympus propagation studies in the US: Receiver development and the data acquisition system

    NASA Technical Reports Server (NTRS)

    Mckeeman, John C.

    1990-01-01

    Virginia Tech has developed two types of receivers to monitor the Olympus beacons, as well as a custom data acquisition system to store and display propagation data. Each of the receiver designs uses new hybrid analog/digital techniques. The data acquisition system uses a stand alone processor to collect and format the data for display and subsequent processing. The launch of the Olympus satellite with its coherent beacons offers new opportunities to study propagation effects at 12.5, 20, and 30 GHz. At Virginia Tech, the satellite is at 14 degrees in elevation, which allows us to measure low elevation angle effects. However, to make these measurements, a very accurate and stable measurement system is required. Virginia Tech has constructed a complex receiving system which monitors the Olympus beacons and all parameters associated with propagation research. In the current configuration, researchers have developed a receiver which frequency locks to the less fade susceptible 12.5 GHz beacon. Since all beacons on the satellite are driven from a single master oscillator, drift in the 12.5 GHz beacon implies corresponding drifts in the 20, and 30 GHz beacons. The receivers for the 20 and 30 GHz systems derive their frequency locking information from the 12.5 GHz system. This widens the dynamic range of the receivers and allows the receivers to maintain lock in severe fade conditions. In addition to monitoring the beacons, the sky noise is monitored with radiometers at each frequency. The radiometer output is used to set the clear air level for each beacon measurement. Researchers also measure the rain rate with several tipping bucket rain gauges placed along the propagation path.

  15. Development of the data acquisition and control system for a portable THz time-domain spectrometer

    NASA Astrophysics Data System (ADS)

    Gao, Weibo; Wang, Yingxin; Zhao, Ziran

    2013-08-01

    This paper discusses the development of data acquisition and control system (DACS) for a portable terahertz time-domain spectrometer (THz-TDS). In this system, field programmable gate array (FPGA) severed as main control unit (MCU), which controls and harmonizes other functional modules of the spectrometer, including the linear delay stage, high voltage modulation and the AD converter. A digital lock-in amplifier implemented within the FPGA is employed to restore the weak THz signal. USB is used as the communication interface between the FPGA and the computer, which transfers commands and THz waveform data. The spectrometer can scan a waveform within a 30-ps time window in about 10 seconds, which has a spectral resolution better than 50GHz and a dynamic range up to 49dB.

  16. Data Acquisition Systems

    NASA Technical Reports Server (NTRS)

    1994-01-01

    In the mid-1980s, Kinetic Systems and Langley Research Center determined that high speed CAMAC (Computer Automated Measurement and Control) data acquisition systems could significantly improve Langley's ARTS (Advanced Real Time Simulation) system. The ARTS system supports flight simulation R&D, and the CAMAC equipment allowed 32 high performance simulators to be controlled by centrally located host computers. This technology broadened Kinetic Systems' capabilities and led to several commercial applications. One of them is General Atomics' fusion research program. Kinetic Systems equipment allows tokamak data to be acquired four to 15 times more rapidly. Ford Motor company uses the same technology to control and monitor transmission testing facilities.

  17. Development of a flight data acquisition system for small unmanned aircraft

    NASA Astrophysics Data System (ADS)

    Hood, Scott

    Current developments surrounding the use of unmanned aerial vehicles have produced a need for a high quality data acquisition platform developed specifically a research environment. This work was undertaken to produce such a system that is low cost, extensible, and better supports fixed wing research through the inclusion of a custom vane based air data probe capable of measuring airspeed, angle of attack, and angle of sideslip. This was accomplished by starting with the open source Pixhawk system as the core and then modifying the device firmware and adding sensors to suit the needs of current aerospace research at OSU. An overview of each component of the system is presented, as well as a description of various firmware modifications to the stock Pixhawk system. Tests were then performed on all of the major sensors using bench testing, wind tunnel analysis, and flight maneuvers to determine the final performance of each part of the system. This research shows that all of the critical sensors on the data acquisition platform produce data acceptable for flight research. The accelerometer has been shown to have an overall tolerance of +/-0.0545 m/s², with +/-0.223 deg/s for the gyroscopic sensor, +/-1.32 hPa for the barometric sensor, +/-0.318 m/s for the airspeed sensor, +/-1.65 °C for the outside air temperature sensor, and +/-0.00115 V for the analog to digital converter. The stock calibration curve for the airspeed sensor was determined to be correct to within +/-0.5 in H2O through wind tunnel testing, and an experimental step input analysis on the flow direction vanes showed that worst case steady state error and time to damp are acceptable for the system. Power spectral density and spectral coherence analysis of flight data was used to show that the custom air data probe is capable of following the flight dynamics of a given aircraft to within a 10 percent tolerance across a range of frequencies. Finally, general performance of the system was proven using

  18. Development of a UAV system for VNIR-TIR acquisitions in precision agriculture

    NASA Astrophysics Data System (ADS)

    Misopolinos, L.; Zalidis, Ch.; Liakopoulos, V.; Stavridou, D.; Katsigiannis, P.; Alexandridis, T. K.; Zalidis, G.

    2015-06-01

    Adoption of precision agriculture techniques requires the development of specialized tools that provide spatially distributed information. Both flying platforms and airborne sensors are being continuously evolved to cover the needs of plant and soil sensing at affordable costs. Due to restrictions in payload, flying platforms are usually limited to carry a single sensor on board. The aim of this work is to present the development of a vertical take-off and landing autonomous unmanned aerial vehicle (VTOL UAV) system for the simultaneous acquisition of high resolution vertical images at the visible, near infrared (VNIR) and thermal infrared (TIR) wavelengths. A system was developed that has the ability to trigger two cameras simultaneously with a fully automated process and no pilot intervention. A commercial unmanned hexacopter UAV platform was optimized to increase reliability, ease of operation and automation. The designed systems communication platform is based on a reduced instruction set computing (RISC) processor running Linux OS with custom developed drivers in an efficient way, while keeping the cost and weight to a minimum. Special software was also developed for the automated image capture, data processing and on board data and metadata storage. The system was tested over a kiwifruit field in northern Greece, at flying heights of 70 and 100m above the ground. The acquired images were mosaicked and geo-corrected. Images from both flying heights were of good quality and revealed unprecedented detail within the field. The normalized difference vegetation index (NDVI) was calculated along with the thermal image in order to provide information on the accurate location of stressors and other parameters related to the crop productivity. Compared to other available sources of data, this system can provide low cost, high resolution and easily repeatable information to cover the requirements of precision agriculture.

  19. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities

    NASA Technical Reports Server (NTRS)

    Hebert, Phillip W., Sr.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Hughes, Mark S.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition systems (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis development and deployment.

  20. Development and Testing of a Variable Conductance Thermal Acquisition, Transport, and Switching System

    NASA Technical Reports Server (NTRS)

    Bugby, D. C.; Farmer, J. T.; Stouffer, C. J.

    2013-01-01

    This paper describes the development and testing of a scalable thermal control architecture for instruments, subsystems, or systems that must operate in severe space environments with wide variations in sink temperature. The architecture is comprised by linking one or more hot-side variable conductance heat pipes (VCHPs) in series with one or more cold-side loop heat pipes (LHPs). The VCHPs provide wide area heat acquisition, limited distance thermal transport, modest against gravity pumping, concentrated LHP startup heating, and high switching ratio variable conductance operation. The LHPs provide localized heat acquisition, long distance thermal transport, significant against gravity pumping, and high switching ratio variable conductance operation. Combining two variable conductance devices in series ensures very high switching ratio isolation from severe environments like the Earth's moon, where each lunar day spans 15 Earth days (270 K sink, with a surface-shielded/space viewing radiator) and each lunar night spans 15 Earth days (80-100 K radiative sink, depending on location). The single VCHP-single LHP system described herein was developed to maintain thermal control of International Lunar Network (ILN) anchor node lander electronics, but it is also applicable to other variable heat rejection space missions in severe environments. The LHPVCHP system utilizes a stainless steel wire mesh wick ammonia VCHP, a Teflon wick propylene LHP, a pair of one-third square meter high ? radiators (one capillary-pumped horizontal radiator and a second gravity-fed vertical radiator), a half-meter of transport distance, and a wick-bearing co-located flow regulator (CLFR) to allow operation with a hot (deactivated) radiator. The VCHP was designed with a small reservoir formed by extending the length of its stainless steel heat pipe tubing. The system was able to provide end-to-end switching ratios of 300-500 during thermal vacuum testing at ATK, including 3-5 W/K ON conductance

  1. HYPERCP data acquisition system

    SciTech Connect

    Kaplan, D.M.; Luebke, W.R.; Chakravorty, A.

    1997-12-31

    For the HyperCP experiment at Fermilab, we have assembled a data acquisition system that records on up to 45 Exabyte 8505 tape drives in parallel at up to 17 MB/s. During the beam spill, data axe acquired from the front-end digitization systems at {approx} 60 MB/s via five parallel data paths. The front-end systems achieve typical readout deadtime of {approx} 1 {mu}s per event, allowing operation at 75-kHz trigger rate with {approx_lt}30% deadtime. Event building and tapewriting are handled by 15 Motorola MVME167 processors in 5 VME crates.

  2. Development of a simple, self-contained flight test data acquisition system

    NASA Technical Reports Server (NTRS)

    Renz, R. R. L.; Clarke, R.; Roskam, J.

    1980-01-01

    The system concepts and the flight test program results for a NASA designed in-flight data acquisition system are described. The system draws power from a rechargeable battery pack and intrudes on the aircraft systems only with a total pressure probe, a static pressure probe, and control position transducers, which are simply taped to the frame. A 4000 byte microcomputer forms the heart of the data recording system for cassette tape storage, and is expansion coupled to an eight-bit interactive microcomputer which interfaces with a transducer package for 16-channel demultiplexing. The transducers, ranges, and accuracies are listed, and a five/sec data acquisition rate minimum requirement is noted, although a 10/sec rate is used. The system components are detailed, along with the control and data processing procedures, and the results of dynamic flight testing are presented.

  3. Automatic carrier acquisition system

    NASA Technical Reports Server (NTRS)

    Bunce, R. C. (Inventor)

    1973-01-01

    An automatic carrier acquisition system for a phase locked loop (PLL) receiver is disclosed. It includes a local oscillator, which sweeps the receiver to tune across the carrier frequency uncertainty range until the carrier crosses the receiver IF reference. Such crossing is detected by an automatic acquisition detector. It receives the IF signal from the receiver as well as the IF reference. It includes a pair of multipliers which multiply the IF signal with the IF reference in phase and in quadrature. The outputs of the multipliers are filtered through bandpass filters and power detected. The output of the power detector has a signal dc component which is optimized with respect to the noise dc level by the selection of the time constants of the filters as a function of the sweep rate of the local oscillator.

  4. Feasibility of developing a portable driver performance data acquisition system for human factors research: Design specifications. Volume 3

    SciTech Connect

    Carter, R.J.; Barickman, F.S.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow driver performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During Phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated. This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volume 2 presents the related appendices. Volume three (this report) displays the design specifications developed for DASCAR during the ``develop design requirements and specifications for a portable driver performance data acquisition system`` task. Design specifications were assembled for each DASCAR element. The specifications were prepared in sufficient detail to allow a third party to use them to design, develop, procure, and subsequently construct the data acquisition system. This report also covers the background to the program.

  5. Centaur propellant acquisition system study

    NASA Technical Reports Server (NTRS)

    Blatt, M. H.; Walter, M. D.

    1975-01-01

    A study was performed to determine the desirability of replacing the hydrogen peroxide settling system on the Centaur D-1S with a capillary acquisition system. A comprehensive screening was performed to select the most promising capillary device fluid acquisition, thermal conditioning, and fabrication techniques. Refillable start baskets and bypass feed start tanks were selected for detailed design. Critical analysis areas were settling and refilling, start sequence development with an initially dry boost pump, and cooling the fluid delivered to the boost pump in order to provide necessary net position suction head (NPSH). Design drawings were prepared for the start basket and start tank concepts for both LO2 and LH2 tanks. System comparisons indicated that the start baskets using wicking for thermal conditioning, and thermal subcooling for boost pump NPSH, are the most desirable systems for future development.

  6. The Development of Data Acquisition and Remote Real-Time Display System for EAST NBI

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaodan; Hu, Chundong; Sheng, Peng; Zhao, Yuanzhe; Wu, Deyun; Cui, Qinglong

    2013-10-01

    The data acquisition and remote real-time display system for the neutral beam injectors (NBI) on experimental advanced superconducting tokamak (EAST) are described in this paper. Distributed computer systems including local data acquisition (DAQ) facility, remote data server (DS), real-time display terminal are adopted with Linux and Windows operating system. Experimental signals are gathered by DAQ device at local working field. On the one hand, these gathered data will be sent to DS which runs on remote server main control layer on EAST NBI control network for saving and processing; on the other hand, these data will be sent to real-time display terminal which runs on remote monitoring layer on EAST NBI for displaying and monitoring experimental signals real-timely. Another point needs to be mentioned is that the real-time display software can call back historical data from DS for querying. The software of data acquisition and DS are programmed by C language while the real-time display software is programmed by Labview flow chart. The hardware mainly includes DAQ cards, server, industrial personal computer and others auxiliary hardware. Now the system proved to be performed well through experiments on NBI testing bed.

  7. Collecting cometary soil samples? Development of the ROSETTA sample acquisition system

    NASA Technical Reports Server (NTRS)

    Coste, P. A.; Fenzi, M.; Eiden, Michael

    1993-01-01

    In the reference scenario of the ROSETTA CNRS mission, the Sample Acquisition System is mounted on the Comet Lander. Its tasks are to acquire three kinds of cometary samples and to transfer them to the Earth Return Capsule. Operations are to be performed in vacuum and microgravity, on a probably rough and dusty surface, in a largely unknown material, at temperatures in the order of 100 K. The concept and operation of the Sample Acquisition System are presented. The design of the prototype corer and surface sampling tool, and of the equipment for testing them at cryogenic temperatures in ambient conditions and in vacuum in various materials representing cometary soil, are described. Results of recent preliminary tests performed in low temperature thermal vacuum in a cometary analog ice-dust mixture are provided.

  8. Development of a Real-Time, High-Speed Distribution Level Data Acquisition System

    SciTech Connect

    Bank, J.; Kroposki, B.

    2012-01-01

    With the development of smart grids and the deployment of their enabling technologies, improved data acquisition will be needed at the distribution level to understand the full impact of these changes. With this in mind, NREL has developed a high-speed measurement and data collection network targeted specifically at the distribution level. This network is based around adaptable, rugged measurement devices designed for deployment at a variety of low and medium voltage locations below the sub-station. Each of these devices is capable of real-time data transmission via an Internet connection. Additionally, several analysis and visualization applications have been developed around the incoming data streams.

  9. System design, development, and production process modeling: A versatile and powerful acquisition management decision support tool

    SciTech Connect

    Rafuse, H.E.

    1996-12-31

    A series of studies have been completed on the manufacturing operations of light, medium, and heavy tactical vehicle system producers to facilitate critical system acquisition resource decisions by the United States Army Program Executive Officer, Tactical Wheeled Vehicles. The principal programs were the Family of Medium Tactical Vehicles (FMTV) production programs at Stewart & Stevenson Services, Inc.; the heavy TWV production programs at the Oshkosh Truck Corporation in Oshkosh, Wisconsin; and the light TWV and 2.5 ton remanufacturing production programs at the AM General Corporation in South Bend, Indiana. Each contractor`s production scenarios were analyzed and modeled to accurately quantify the relationship between production rates and unit costs. Specific objectives included identifying (1) Minimum Sustaining Rates to support current and future budgetary requirements and resource programming for potential follow-on procurements, (2) thresholds where production rate changes significantly affect unit costs, and (3) critical production program factors and their impacts to production rate versus unit cost relationships. Two different techniques were utilized initially in conducting the analyses. One technique principally focused on collecting and analyzing applicable historical production program information, where available, to develop a statistical predictive model. A second and much more exhaustive technique focused on a detailed modeling of each contractor`s production processes, flows, and operations. A standard architecture of multiple linked functional modules was used for each process model. Using the standard architecture, the individual modules were tailored to specific contractor operations. Each model contains detailed information on manpower, burden rates, material, material price/quantity relationships, capital, manufacturing support, program management, and all related direct and indirect costs applicable to the production programs.

  10. Fast Access Data Acquisition System

    SciTech Connect

    Dr. Vladimir Katsman

    1998-03-17

    Our goal in this program is to develop Fast Access Data Acquisition System (FADAS) by combining the flexibility of Multilink's GaAs and InP electronics and electro-optics with an extremely high data rate for the efficient handling and transfer of collider experimental data. This novel solution is based on Multilink's and Los Alamos National Laboratory's (LANL) unique components and technologies for extremely fast data transfer, storage, and processing.

  11. Aerial robotic data acquisition system

    SciTech Connect

    Hofstetter, K.J.; Hayes, D.W.; Pendergast, M.M.; Corban, J.E.

    1993-12-31

    A small, unmanned aerial vehicle (UAV), equipped with sensors for physical and chemical measurements of remote environments, is described. A miniature helicopter airframe is used as a platform for sensor testing and development. The sensor output is integrated with the flight control system for real-time, interactive, data acquisition and analysis. Pre-programmed flight missions will be flown with several sensors to demonstrate the cost-effective surveillance capabilities of this new technology.

  12. A UMLS-based Knowledge Acquisition Tool for Rule-based Clinical Decision Support System Development

    PubMed Central

    Achour, Soumeya L.; Dojat, Michel; Rieux, Claire; Bierling, Philippe; Lepage, Eric

    2001-01-01

    Decision support systems in the medical field have to be easily modified by medical experts themselves. The authors have designed a knowledge acquisition tool to facilitate the creation and maintenance of a knowledge base by the domain expert and its sharing and reuse by other institutions. The Unified Medical Language System (UMLS) contains the domain entities and constitutes the relations repository from which the expert builds, through a specific browser, the explicit domain ontology. The expert is then guided in creating the knowledge base according to the pre-established domain ontology and condition–action rule templates that are well adapted to several clinical decision-making processes. Corresponding medical logic modules are eventually generated. The application of this knowledge acquisition tool to the construction of a decision support system in blood transfusion demonstrates the value of such a pragmatic methodology for the design of rule-based clinical systems that rely on the highly progressive knowledge embedded in hospital information systems. PMID:11418542

  13. Development of a data acquisition and analysis system for nociceptive withdrawal reflex and reflex receptive fields in humans.

    PubMed

    Biurrun Manresa, Jose A; Hansen, John; Andersen, Ole K

    2010-01-01

    A system for data acquisition and analysis of nociceptive withdrawal reflex (NWR) and reflex receptive field (RRF) is introduced. The system is constituted by hardware and software components. The hardware consists of devices commonly used for electrical stimulation and electromyographic and kinematic data recording. The software comprises two different programs: Wirex, a stand-alone program developed in LabView for data acquisition, and Reflex Lab, a Matlab-based toolbox for data analysis. These programs were developed to maximize the potential of the hardware, turning it into a complete stimulation system capable of automatic quantification of NWR and RRF. In this article, a brief review of NWR and RRF analysis is presented, the system features are described in detail and its present and future applications are discussed. PMID:21096727

  14. Development of an XYZ Digital Camera with Embedded Color Calibration System for Accurate Color Acquisition

    NASA Astrophysics Data System (ADS)

    Kretkowski, Maciej; Jablonski, Ryszard; Shimodaira, Yoshifumi

    Acquisition of accurate colors is important in the modern era of widespread exchange of electronic multimedia. The variety of device-dependent color spaces causes troubles with accurate color reproduction. In this paper we present the outlines of accomplished digital camera system with device-independent output formed from tristimulus XYZ values. The outstanding accuracy and fidelity of acquired color is achieved in our system by employing an embedded color calibration system based on emissive device generating reference calibration colors with user-defined spectral distribution and chromaticity coordinates. The system was tested by calibrating the camera using 24 reference colors spectrally reproduced from 24 color patches of the Macbeth Chart. The average color difference (CIEDE2000) has been found to be ΔE =0.83, which is an outstanding result compared to commercially available digital cameras.

  15. Development and application of a light-weight, wind-turbine rotor-based data acquisition system

    SciTech Connect

    Berg, D.E.; Robertson, P.J.; Ortiz, M.F.

    1998-04-01

    Wind-energy researchers at the National Wind Technology Center (NWTC), representing Sandia National Laboratories (SNL) and the National Renewable Energy Laboratory (NREL), are developing a new, light-weight, modular data acquisition unit capable of acquiring long-term, continuous time-series data from small and/or dynamic wind-turbine rotors. The unit utilizes commercial data acquisition hardware, spread-spectrum radio modems, and Global Positioning System receivers, and a custom-built programmable logic device. A prototype of the system is now operational, and initial field deployment is expected this summer. This paper describes the major subsystems comprising the unit, summarizes the current status of the system, and presents the current plans for near-term development of hardware and software.

  16. Ocean Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Johnson, B.; Cavanaugh, J.; Smith, J.; Esaias, W.

    1988-01-01

    The Ocean Data Acquisition System (ODAS) is a low cost instrument with potential commercial application. It is easily mounted on a small aircraft and flown over the coastal zone ocean to remotely measure sea surface temperature and three channels of ocean color information. From this data, chlorophyll levels can be derived for use by ocean scientists, fisheries, and environmental offices. Data can be transmitted to shipboard for real-time use with sea truth measurements, ocean productivity estimates and fishing fleet direction. The aircraft portion of the system has two primary instruments: an IR radiometer to measure sea surface temperature and a three channel visible spectro-radiometer for 460, 490, and 520 nm wavelength measurements from which chlorophyll concentration can be derived. The aircraft package contains a LORAN-C unit for aircraft location information, clock, on-board data processor and formatter, digital data storage, packet radio terminal controller, and radio transceiver for data transmission to a ship. The shipboard package contains a transceiver, packet terminal controller, data processing and storage capability, and printer. Both raw data and chlorophyll concentrations are available for real-time analysis.

  17. The Chateau de Cristal data acquisition system

    SciTech Connect

    Villard, M.M.

    1987-08-01

    This data acquisition system is built on several dedicated data transfer buses: ADC data readout through the FERA bus, parallel data processing in two VME crates. High data rates and selectivities are performed via this acquisition structure and new developed processing units. The system modularity allows various experiments with additional detectors.

  18. Development and operation of a real-time data acquisition system for the NASA-LaRC differential absorption lidar

    NASA Technical Reports Server (NTRS)

    Butler, C.

    1985-01-01

    Computer hardware and software of the NASA multipurpose differential absorption lidar (DIAL) sysatem were improved. The NASA DIAL system is undergoing development and experimental deployment for remote measurement of atmospheric trace gas concentration from ground and aircraft platforms. A viable DIAL system was developed with the capability of remotely measuring O3 and H2O concentrations from an aircraft platform. Test flights were successfully performed on board the NASA/Goddard Flight Center Electra aircraft from 1980 to 1984. Improvements on the DIAL data acquisition system (DAS) are described.

  19. DEAP-3600 Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Lindner, Thomas

    2015-12-01

    DEAP-3600 is a dark matter experiment using liquid argon to detect Weakly Interacting Massive Particles (WIMPs). The DEAP-3600 Data Acquisition (DAQ) has been built using a combination of commercial and custom electronics, organized using the MIDAS framework. The DAQ system needs to suppress a high rate of background events from 39Ar beta decays. This suppression is implemented using a combination of online firmware and software-based event filtering. We will report on progress commissioning the DAQ system, as well as the development of the web-based user interface.

  20. TFTR diagnostic control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Sauthoff, N. R.; Daniels, R. E.

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man-machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ``groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  1. TFTR diagnostic control and data acquisition system

    SciTech Connect

    Sauthoff, N.R.; Daniels, R.E.; PPL Computer Division

    1985-05-01

    General computerized control and data-handling support for TFTR diagnostics is presented within the context of the Central Instrumentation, Control and Data Acquisition (CICADA) System. Procedures, hardware, the interactive man--machine interface, event-driven task scheduling, system-wide arming and data acquisition, and a hierarchical data base of raw data and results are described. Similarities in data structures involved in control, monitoring, and data acquisition afford a simplification of the system functions, based on ''groups'' of devices. Emphases and optimizations appropriate for fusion diagnostic system designs are provided. An off-line data reduction computer system is under development.

  2. Language Acquisition and Language Learning: Developing the System of External and Internal Perspectives

    ERIC Educational Resources Information Center

    Zascerinska, Jelena

    2010-01-01

    Introduction. The use of three-five languages is of the greatest importance in order to form varied cooperative networks for the creation of new knowledge. Aim of the paper is to analyze the synergy between language acquisition and language learning. Materials and Methods. The search for the synergy between language acquisition and language…

  3. Feasibility of developing a portable driver performance data acquisition system for human factors research: Technical tasks. Volume 1

    SciTech Connect

    Carter, R.J.; Barickman, F.S.; Spelt, P.F.; Schmoyer, R.L.; Kirkpatrick, J.R.

    1998-01-01

    A two-phase, multi-year research program entitled ``development of a portable driver performance data acquisition system for human factors research`` was recently completed. The primary objective of the project was to develop a portable data acquisition system for crash avoidance research (DASCAR) that will allow drive performance data to be collected using a large variety of vehicle types and that would be capable of being installed on a given vehicle type within a relatively short-time frame. During phase 1 a feasibility study for designing and fabricating DASCAR was conducted. In phase 2 of the research DASCAR was actually developed and validated. This technical memorandum documents the results from the feasibility study. It is subdivided into three volumes. Volume one (this report) addresses the last five items in the phase 1 research and the first issue in the second phase of the project. Volumes two and three present the related appendices, and the design specifications developed for DASCAR respectively. The six tasks were oriented toward: identifying parameters and measures; identifying analysis tools and methods; identifying measurement techniques and state-of-the-art hardware and software; developing design requirements and specifications; determining the cost of one or more copies of the proposed data acquisition system; and designing a development plan and constructing DASCAR. This report also covers: the background to the program; the requirements for the project; micro camera testing; heat load calculations for the DASCAR instrumentation package in automobile trunks; phase 2 of the research; the DASCAR hardware and software delivered to the National Highway Traffic Safety Administration; and crash avoidance problems that can be addressed by DASCAR.

  4. Development and application of a model for the analysis of trades between space launch system operations and acquisition costs

    NASA Astrophysics Data System (ADS)

    Nix, Michael B.

    2005-12-01

    Early design decisions in the development of space launch systems determine the costs to acquire and operate launch systems. Some sources indicate that as much as 90% of life cycle costs are fixed by the end of the critical design review phase. System characteristics determined by these early decisions are major factors in the acquisition cost of flight hardware elements and facilities and influence operations costs through the amount of maintenance and support labor required to sustain system function. Operations costs are also dependent on post-development management decisions regarding how much labor will be deployed to meet requirements of market demand and ownership profit. The ability to perform early trade-offs between these costs is vital to the development of systems that have the necessary capacity to provide service and are profitable to operate. An Excel-based prototype model was developed for making early analyses of trade-offs between the costs to operate a space launch system and to acquire the necessary assets to meet a given set of operational requirements. The model, integrating input from existing models and adding missing capability, allows the user to make such trade-offs across a range of operations concepts (required flight rates, staffing levels, shifts per workday, workdays per week and per year, unreliability, wearout and depot maintenance) and the number, type and capability of assets (flight hardware elements, processing and supporting facilities and infrastructure). The costs and capabilities of hypothetical launch systems can be modeled as a function of interrelated turnaround times and labor resource levels, and asset loss and retirement. The number of flight components and facilities required can be calculated and the operations and acquisition costs compared for a specified scenario. Findings, based on the analysis of a hypothetical two stage to orbit, reusable, unmanned launch system, indicate that the model is suitable for the

  5. Standard GANIL data acquisition system

    NASA Astrophysics Data System (ADS)

    Raine, B.; Tripon, M.; Piquet, B.

    1994-02-01

    We report on the GANIL general data acquisition system based on VME crates distributed in several experiments areas, linked to a VAX cluster by optical fibers and Ethernet for control and storage. Acquisition buses are CAMAC, FERA and VXI. We present the system configuration, experiments description procedure, and adaptation for VXI and remote controls for the 4 INDRA detector. We also discus the INDRA asynchronous electronics trigger.

  6. Evolving U.S. Department of Defense (DoD) unmanned systems research, development, test, acquisition, and evaluation (RDTA&E)

    NASA Astrophysics Data System (ADS)

    Laird, Robin T.

    2009-05-01

    As research, development, test, acquisition and evaluation (RDTA&E) of unmanned systems experiences increased attention by the Department of Defense (DoD), elements within the acquisition community are responding by mapping out changes to management systems, including fundamental policy shifts, to support the expanding role of robots on the battlefield. Unmanned systems - air, land, and sea - are increasing in complexity and capability such that their use is becoming pervasive in mission areas such as explosives ordnance disposal and aerial surveillance. This paper reviews the state of unmanned systems RDTA&E within the context of Defense Acquisition, highlighting existing and emerging public policy, relevant acquisition reform, the resulting organizational adaptations, and the success with which one enterprise has brought together the sometimes competing values found within the major elements of the larger acquisition system.

  7. Development and Evaluation of an Educational Data Acquisition System for Use in Secondary Schools. Technical Note 411.

    ERIC Educational Resources Information Center

    Jernstedt, G. Christian; And Others

    The purpose of this research was to design, create a prototype, and evaluate an Educational Data Acquisition System (EDAS) for use in secondary school science laboratories. The prototype of EDAS consisted of a microcomputer, data acquisition interface, sensors, software, and documentation. It provided the teacher and students with a…

  8. Rotor fatigue monitoring data acquisition system

    NASA Technical Reports Server (NTRS)

    Smith, Scott M.

    1993-01-01

    The 40 by 80 Foot Wind Tunnel of the National Full Scale Aerodynamics Complex (NFAC) had a requirement to monitor rotor fatigue during a test. This test subjected various rotor components to stress levels higher than their structural fatigue limits. A data acquisition system was developed to monitor the cumulative fatigue damage of rotor components using National Instruments hardware and LabVIEW software. A full description of the data acquisition system including its configuration and salient features, is presented in this paper.

  9. Development of a novel antimicrobial screening system targeting the pyoverdine-mediated iron acquisition system and xenobiotic efflux pumps.

    PubMed

    Sato, Kazuki; Ushioda, Kenichi; Akiba, Keiji; Matsumoto, Yoshimi; Maseda, Hideaki; Ando, Tasuke; Isogai, Emiko; Nakae, Taiji; Yoneyama, Hiroshi

    2015-01-01

    The iron acquisition systems in Pseudomonas aeruginosa are inducible in response to low-iron conditions and important for growth of this organism under iron limitation. OprM is the essential outer membrane subunit of the MexAB-OprM xenobiotic efflux pump. We designed and constructed a new model antimicrobial screening system targeting both the iron-uptake system and xenobiotic efflux pumps. The oprM gene was placed immediately downstream of the ferri-pyoverdine receptor gene, fpvA, in the host lacking chromosomal oprM and the expression of oprM was monitored by an antibiotic susceptibility test under iron depleted and replete conditions. The recombinant cells showed wild-type susceptibility to pump substrate antibiotics, e.g., aztreonam, under iron limitation and became supersusceptible to them under iron repletion, suggesting that expression of oprM is under control of the iron acquisition system. Upon screening of a chemical library comprising 2952 compounds using this strain, a compound-ethyl 2-(1-acetylpiperidine-4-carboxamido)-4,5,6,7-tetrahydrobenzo[b]thiophene-3-carboxylate-was found to enhance the efficacy of aztreonam under iron limitation, suggesting that the compound inhibits either the iron acquisition system or the MexAB-OprM efflux pump. This compound was subsequently found to inhibit the growth of wild-type cells in the presence of sublethal amounts of aztreonam, regardless of the presence or absence of dipyridyl, an iron-chelator. The compound was eventually identified to block the function of the MexAB-OprM efflux pump, showing the validity of this new method. PMID:25939068

  10. SHARP's systems engineering challenge: rectifying integrated product team requirements with performance issues in an evolutionary spiral development acquisition

    NASA Astrophysics Data System (ADS)

    Kuehl, C. Stephen

    2003-08-01

    Completing its final development and early deployment on the Navy's multi-role aircraft, the F/A-18 E/F Super Hornet, the SHAred Reconnaissance Pod (SHARP) provides the war fighter with the latest digital tactical reconnaissance (TAC Recce) Electro-Optical/Infrared (EO/IR) sensor system. The SHARP program is an evolutionary acquisition that used a spiral development process across a prototype development phase tightly coupled into overlapping Engineering and Manufacturing Development (EMD) and Low Rate Initial Production (LRIP) phases. Under a tight budget environment with a highly compressed schedule, SHARP challenged traditional acquisition strategies and systems engineering (SE) processes. Adopting tailored state-of-the-art systems engineering process models allowd the SHARP program to overcome the technical knowledge transition challenges imposed by a compressed program schedule. The program's original goal was the deployment of digital TAC Recce mission capabilities to the fleet customer by summer of 2003. Hardware and software integration technical challenges resulted from requirements definition and analysis activities performed across a government-industry led Integrated Product Team (IPT) involving Navy engineering and test sites, Boeing, and RTSC-EPS (with its subcontracted hardware and government furnished equipment vendors). Requirements development from a bottoms-up approach was adopted using an electronic requirements capture environment to clarify and establish the SHARP EMD product baseline specifications as relevant technical data became available. Applying Earned-Value Management (EVM) against an Integrated Master Schedule (IMS) resulted in efficiently managing SE task assignments and product deliveries in a dynamically evolving customer requirements environment. Application of Six Sigma improvement methodologies resulted in the uncovering of root causes of errors in wiring interconnectivity drawings, pod manufacturing processes, and avionics

  11. Design and Development of a High-Speed Data-Acquisition System for the Korean VLBI Network

    NASA Astrophysics Data System (ADS)

    Oh, Se-Jin; Roh, Duk-Gyoo; Wajima, Kiyoaki; Kawaguchi, Noriyuki; Byun, Do-Young; Yeom, Jae-Hwan; Je, Do-Heung; Han, Seog-Tae; Iguchi, Satoru; Kawakami, Kazuyuki; Ozeki, Kensuke; Kobayashi, Hideyuki; Sasao, Tetsuo; Sohn, Bongwon; Kim, Jaeheon; Miyazaki, Atsushi; Oyama, Tomoaki; Kurayama, Tomoharu

    2011-12-01

    A new high-speed Data Acquisition System (DAS) has been developed for the millimeter-wave VLBI array newly constructed in Korea, the Korean VLBI Network (KVN). The KVN DAS is specially designed to support the most distinctive feature of the KVN, that is simultaneous reception of multiple frequency bands (22, 43, 86 and 129-GHz bands in the current KVN system) for realizing multi-frequency phase referencing, which is the key technology for successful millimeter-wave VLBI observations toward active galactic nuclei and astronomical maser sources. Although the basic functions of the KVN DAS succeed technological elements originally developed in the VERA (VLBI Exploration of Radio Astrometry) Project, essentially new designs have been introduced for the simultaneous processing of four data streams in the optical data-transmission system, the digital filter, and the digital spectrometer. The KVN DAS system consists of four Gigabit Samplers (GBS), Optical Transmission System (OTS), Digital Filter Bank (DFB), Digital Spectrometer (DSM), and the data recorder. The DFB realizes very flexible and phase-stable channelization of up to four data streams. The DSM facilitates quick look of power and cross-power spectra of observed data. The VLBI output data from the DFB are recorded to the Mark5B recorder with a maximum rate of 1-Gbps. We discuss in the present paper the primary specifications, designs, and experimental results of the KVN DAS system.

  12. Two Demonstrations with a New Data-Acquisition System

    ERIC Educational Resources Information Center

    Kraftmakher, Yaakov

    2014-01-01

    Nowadays, the use of data-acquisition systems in undergraduate laboratories is routine. Many computer-assisted experiments became possible with the PASCO scientific data-acquisition system based on the 750 Interface and DataStudio software. A new data-acquisition system developed by PASCO includes the 850 Universal Interface and Capstone software.…

  13. Systems in Development: Motor Skill Acquisition Facilitates 3D Object Completion

    PubMed Central

    Soska, Kasey C.; Adolph, Karen E.; Johnson, Scott P.

    2009-01-01

    How do infants learn to perceive the backs of objects that they see only from a limited viewpoint? Infants’ 3D object completion abilities emerge in conjunction with developing motor skills—independent sitting and visual-manual exploration. Twenty-eight 4.5- to 7.5-month-old infants were habituated to a limited-view object and tested with volumetrically complete and incomplete (hollow) versions of the same object. Parents reported infants’ sitting experience, and infants’ visual-manual exploration of objects was observed in a structured play session. Infants’ self-sitting experience and visual-manual exploratory skills predicted looking to the novel, incomplete object on the habituation task. Further analyses revealed that self-sitting facilitated infants’ visual inspection of objects while they manipulated them. The results are framed within a developmental systems approach, wherein infants’ sitting skill, multimodal object exploration, and object knowledge are linked in developmental time. PMID:20053012

  14. Systems in development: motor skill acquisition facilitates three-dimensional object completion.

    PubMed

    Soska, Kasey C; Adolph, Karen E; Johnson, Scott P

    2010-01-01

    How do infants learn to perceive the backs of objects that they see only from a limited viewpoint? Infants' 3-dimensional object completion abilities emerge in conjunction with developing motor skills--independent sitting and visual-manual exploration. Infants at 4.5 to 7.5 months of age (n = 28) were habituated to a limited-view object and tested with volumetrically complete and incomplete (hollow) versions of the same object. Parents reported infants' sitting experience, and infants' visual-manual exploration of objects was observed in a structured play session. Infants' self-sitting experience and visual-manual exploratory skills predicted looking at the novel, incomplete object on the habituation task. Further analyses revealed that self-sitting facilitated infants' visual inspection of objects while they manipulated them. The results are framed within a developmental systems approach, wherein infants' sitting skill, multimodal object exploration, and object knowledge are linked in developmental time. PMID:20053012

  15. WRATS Integrated Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Piatak, David J.

    2008-01-01

    The Wing and Rotor Aeroelastic Test System (WRATS) data acquisition system (DAS) is a 64-channel data acquisition display and analysis system specifically designed for use with the WRATS 1/5-scale V-22 tiltrotor model of the Bell Osprey. It is the primary data acquisition system for experimental aeroelastic testing of the WRATS model for the purpose of characterizing the aeromechanical and aeroelastic stability of prototype tiltrotor configurations. The WRATS DAS was also used during aeroelastic testing of Bell Helicopter Textron s Quad-Tiltrotor (QTR) design concept, a test which received international attention. The LabVIEW-based design is portable and capable of powering and conditioning over 64 channels of dynamic data at sampling rates up to 1,000 Hz. The system includes a 60-second circular data archive, an integrated model swashplate excitation system, a moving block damping application for calculation of whirl flutter mode subcritical damping, a loads and safety monitor, a pilot-control console display, data analysis capabilities, and instrumentation calibration functions. Three networked computers running custom-designed LabVIEW software acquire data through National Instruments data acquisition hardware. The aeroelastic model (see figure) was tested with the DAS at two facilities at NASA Langley, the Transonic Dynamics Tunnel (TDT) and the Rotorcraft Hover Test Facility (RHTF). Because of the need for seamless transition between testing at these facilities, DAS is portable. The software is capable of harmonic analysis of periodic time history data, Fast Fourier Transform calculations, power spectral density calculations, and on-line calibration of test instrumentation. DAS has a circular buffer archive to ensure critical data is not lost in event of model failure/incident, as well as a sample-and-hold capability for phase-correct time history data.

  16. Development of a simple, self-contained flight test data acquisition system

    NASA Technical Reports Server (NTRS)

    Clarke, R.; Shane, D.; Roskam, J.; Rummer, D. I.

    1982-01-01

    The flight test system described combines state-of-the-art microprocessor technology and high accuracy instrumentation with parameter identification technology which minimize data and flight time requirements. The system was designed to avoid permanent modifications of the test airplane and allow quick installation. It is capable of longitudinal and lateral-directional stability and control derivative estimation. Details of this system, calibration and flight test procedures, and the results of the Cessna 172 flight test program are presented. The system proved easy to install, simple to operate, and capable of accurate estimation of stability and control parameters in the Cessna 172 flight tests.

  17. Common Data Acquisition Systems (DAS) Software Development for Rocket Propulsion Test (RPT) Test Facilities - A General Overview

    NASA Technical Reports Server (NTRS)

    Hebert, Phillip W., Sr.; Hughes, Mark S.; Davis, Dawn M.; Turowski, Mark P.; Holladay, Wendy T.; Marshall, PeggL.; Duncan, Michael E.; Morris, Jon A.; Franzl, Richard W.

    2012-01-01

    The advent of the commercial space launch industry and NASA's more recent resumption of operation of Stennis Space Center's large test facilities after thirty years of contractor control resulted in a need for a non-proprietary data acquisition system (DAS) software to support government and commercial testing. The software is designed for modularity and adaptability to minimize the software development effort for current and future data systems. An additional benefit of the software's architecture is its ability to easily migrate to other testing facilities thus providing future commonality across Stennis. Adapting the software to other Rocket Propulsion Test (RPT) Centers such as MSFC, White Sands, and Plumbrook Station would provide additional commonality and help reduce testing costs for NASA. Ultimately, the software provides the government with unlimited rights and guarantees privacy of data to commercial entities. The project engaged all RPT Centers and NASA's Independent Verification & Validation facility to enhance product quality. The design consists of a translation layer which provides the transparency of the software application layers to underlying hardware regardless of test facility location and a flexible and easily accessible database. This presentation addresses system technical design, issues encountered, and the status of Stennis' development and deployment.

  18. Data acquisition system for SLD

    SciTech Connect

    Sherden, D.J.

    1985-05-01

    This paper describes the data acquisition system planned for the SLD detector which is being constructed for use with the SLAC Linear Collider (SLC). An exclusively FASTBUS front-end system is used together with a VAX-based host system. While the volume of data transferred does not challenge the band-width capabilities of FASTBUS, extensive use is made of the parallel processing capabilities allowed by FASTBUS to reduce the data to a size which can be handled by the host system. The low repetition rate of the SLC allows a relatively simple software-based trigger. The principal components and overall architecture of the hardware and software are described.

  19. Development of a portable electrical impedance tomography data acquisition system for near-real-time spatial sensing

    NASA Astrophysics Data System (ADS)

    Huang, Shieh-Kung; Loh, Kenneth J.

    2015-04-01

    The main goal of this study was to develop and validate the performance of a miniature and portable data acquisition (DAQ) system designed for interrogating carbon nanotube (CNT)-based thin films for real-time spatial structural sensing and damage detection. Previous research demonstrated that the electrical properties of CNT-based thin film strain sensors were linearly correlated with applied strains. When coupled with an electrical impedance tomography (EIT) algorithm, the detection and localization of damage was possible. In short, EIT required that the film or "sensing skin" be interrogated along its boundaries. Electrical current was injected across a pair of boundary electrodes, and voltage was simultaneously recorded along the remaining electrode pairs. This was performed multiple times to obtain a large dataset needed for solving the EIT spatial conductivity mapping inverse problem. However, one of the main limitations of this technique was the large amount of time required for data acquisition. In order to facilitate the adoption of this technology and for field implementation purposes, a miniature DAQ that could interrogate these CNT-based sensing skins at high sampling rates was designed and tested. The prototype DAQ featured a Howland current source that could generate stable and controlled direct current. Measurement of boundary electrode voltages and the switching of the input, output, and measurement channels were achieved using multiplexer units. The DAQ prototype was fabricated on a two-layer printed circuit board, and it was designed for integration with a prototype wireless sensing system, which is the next phase of this research.

  20. Enhanced Data-Acquisition System

    NASA Technical Reports Server (NTRS)

    Mustain, Roy W.

    1990-01-01

    Time-consuming, costly digitization of analog signals on magnetic tape eliminated. Proposed data-acquisition system provides nearly immediate access to data in incoming signals by digitizing and recording them both on magnetic tape and on optical disk. Tape and/or disk later played back to reconstruct signals in analog or digital form for analysis. Of interest in industrial and scientific applications in which necessary to digitize, store, and/or process large quantities of experimental data.

  1. Development of a pointing, acquisition, and tracking system for a CubeSat optical communication module

    NASA Astrophysics Data System (ADS)

    Nguyen, Tam; Riesing, Kathleen; Kingsbury, Ryan; Cahoy, Kerri

    2015-03-01

    Miniaturized satellites such as CubeSats continue to improve their capabilities to enable missions that can produce significant amounts of data. For most CubeSat missions, data must be downlinked during short low-earth orbit ground station passes, a task currently performed using traditional radio systems. Free-space optical communications take advantage of the high gain of a narrow optical beam to achieve better link efficiency, allowing more valuable data to be downlinked over the mission lifetime. We present the Nanosatellite Optical Downlink Experiment (NODE) design, capable of providing a typical 3U (30 x 10 x 10 cm) CubeSat with a comparatively high data-rate downlink. The NODE optical communication module is designed to fit within a 5 x 10 x 10 cm volume, weigh less than 1 kg, and consume no more than 10Wof power during active communication periods. Our design incorporates a fine-steering mechanism and beacon-tracking system to achieve a 10 Mbps link rate. We describe the system-level requirements and designs for key components, including a transmitter, a beacon tracking camera, and a fast-steering mirror. We present simulation results of the uplink beacon tracking and fine steering of the downlink beam, including the effects of atmospheric fading and on-orbit environmental disturbances to demonstrate the feasibility of this approach.

  2. NASA Data Acquisitions System (NDAS) Software Architecture

    NASA Technical Reports Server (NTRS)

    Davis, Dawn; Duncan, Michael; Franzl, Richard; Holladay, Wendy; Marshall, Peggi; Morris, Jon; Turowski, Mark

    2012-01-01

    The NDAS Software Project is for the development of common low speed data acquisition system software to support NASA's rocket propulsion testing facilities at John C. Stennis Space Center (SSC), White Sands Test Facility (WSTF), Plum Brook Station (PBS), and Marshall Space Flight Center (MSFC).

  3. DATA ACQUISITION SYSTEM FOR RAPID KINETIC EXPERIMENTS

    EPA Science Inventory

    A data acquisition system has been developed to collect, analyze and store large volumes of rapid kinetic data measured from a stopped-flow spectrophotometer. A digital minicomputer, with an A/D converter, tape drive unit and formatter, analog recorder, oscilloscope, and input/ou...

  4. A New Data Acquisition System for TDPAC

    NASA Astrophysics Data System (ADS)

    Zuo, Yi; Yuan, Daqing; Zheng, Yongnan; Wang, Zhiqian; Fan, Ping; Zhou, Dongmei; Wu, Yongle; Zhu, Jiliang; Zhu, Shengyun

    2010-03-01

    A new data acquisition system for TDPAC measurements with a 6 BaF2-detectors spectrometer has been developed using multi-channel TDC and ADC. The major advantage of this system is that most of functions is implemented by the software instead of the hardware, so that the electronics of the system is rather simple and easily adjusted. Also, there is no limit on the numbers of energy windows, and it is easy to add more detectors.

  5. On Shaft Data Acquisition System (OSDAS)

    NASA Technical Reports Server (NTRS)

    Pedings, Marc; DeHart, Shawn; Formby, Jason; Naumann, Charles

    2012-01-01

    On Shaft Data Acquisition System (OSDAS) is a rugged, compact, multiple-channel data acquisition computer system that is designed to record data from instrumentation while operating under extreme rotational centrifugal or gravitational acceleration forces. This system, which was developed for the Heritage Fuel Air Turbine Test (HFATT) program, addresses the problem of recording multiple channels of high-sample-rate data on most any rotating test article by mounting the entire acquisition computer onboard with the turbine test article. With the limited availability of slip ring wires for power and communication, OSDAS utilizes its own resources to provide independent power and amplification for each instrument. Since OSDAS utilizes standard PC technology as well as shared code interfaces with the next-generation, real-time health monitoring system (SPARTAA Scalable Parallel Architecture for Real Time Analysis and Acquisition), this system could be expanded beyond its current capabilities, such as providing advanced health monitoring capabilities for the test article. High-conductor-count slip rings are expensive to purchase and maintain, yet only provide a limited number of conductors for routing instrumentation off the article and to a stationary data acquisition system. In addition to being limited to a small number of instruments, slip rings are prone to wear quickly, and introduce noise and other undesirable characteristics to the signal data. This led to the development of a system capable of recording high-density instrumentation, at high sample rates, on the test article itself, all while under extreme rotational stress. OSDAS is a fully functional PC-based system with 48 channels of 24-bit, high-sample-rate input channels, phase synchronized, with an onboard storage capacity of over 1/2-terabyte of solid-state storage. This recording system takes a novel approach to the problem of recording multiple channels of instrumentation, integrated with the test

  6. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor, Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2005-01-01

    A measurement acquisition method that alleviates many shortcomings of traditional measurement systems is presented in this paper. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed.

  7. Data Acquisition for Modular Biometric Monitoring System

    NASA Technical Reports Server (NTRS)

    Chmiel, Alan J. (Inventor); Humphreys, Bradley T. (Inventor); Grodsinsky, Carlos M. (Inventor)

    2014-01-01

    A modular system for acquiring biometric data includes a plurality of data acquisition modules configured to sample biometric data from at least one respective input channel at a data acquisition rate. A representation of the sampled biometric data is stored in memory of each of the plurality of data acquisition modules. A central control system is in communication with each of the plurality of data acquisition modules through a bus. The central control system is configured to collect data asynchronously, via the bus, from the memory of the plurality of data acquisition modules according to a relative fullness of the memory of the plurality of data acquisition modules.

  8. Development and operation of a real-time data acquisition system for the NASA, Langley Research Center Differential Absorption Lidar

    NASA Technical Reports Server (NTRS)

    Butler, C.; Kindle, E. C.

    1984-01-01

    The capabilities of the DIAL data acquisition system (DAS) for the remote measurement of atmospheric trace gas concentrations from ground and aircraft platforms were extended through the purchase and integration of other hardware and the implementation of improved software. An operational manual for the current system is presented. Hardware and peripheral device registers are outlined only as an aid in debugging any DAS problems which may arise.

  9. The ALICE data acquisition system

    NASA Astrophysics Data System (ADS)

    Carena, F.; Carena, W.; Chapeland, S.; Chibante Barroso, V.; Costa, F.; Dénes, E.; Divià, R.; Fuchs, U.; Grigore, A.; Kiss, T.; Simonetti, G.; Soós, C.; Telesca, A.; Vande Vyvre, P.; von Haller, B.

    2014-03-01

    In this paper we describe the design, the construction, the commissioning and the operation of the Data Acquisition (DAQ) and Experiment Control Systems (ECS) of the ALICE experiment at the CERN Large Hadron Collider (LHC). The DAQ and the ECS are the systems used respectively for the acquisition of all physics data and for the overall control of the experiment. They are two computing systems made of hundreds of PCs and data storage units interconnected via two networks. The collection of experimental data from the detectors is performed by several hundreds of high-speed optical links. We describe in detail the design considerations for these systems handling the extreme data throughput resulting from central lead ions collisions at LHC energy. The implementation of the resulting requirements into hardware (custom optical links and commercial computing equipment), infrastructure (racks, cooling, power distribution, control room), and software led to many innovative solutions which are described together with a presentation of all the major components of the systems, as currently realized. We also report on the performance achieved during the first period of data taking (from 2009 to 2013) often exceeding those specified in the DAQ Technical Design Report.

  10. The NIFFTE Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Qu, Hai; Niffte Collaboration

    2011-10-01

    The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) will employ a novel, high granularity, pressurized Time Projection Chamber to measure fission cross-sections of the major actinides to high precision over a wide incident neutron energy range. These results will improve nuclear data accuracy and benefit the fuel cycle in the future. The NIFFTE data acquisition system (DAQ) has been designed and implemented on the prototype TPC. Lessons learned from engineering runs have been incorporated into some design changes that are being implemented before the next run cycle. A fully instrumented sextant of EtherDAQ cards (16 sectors, 496 channels) will be used for the next run cycle. The Maximum Integrated Data Acquisition System (MIDAS) has been chosen and customized to configure and run the experiment. It also meets the requirement for remote control and monitoring of the system. The integration of the MIDAS online database with the persistent PostgreSQL database has been implemented for experiment usage. The detailed design and current status of the DAQ system will be presented.

  11. Implementation of Remote Acquisition and Storage System

    NASA Technical Reports Server (NTRS)

    Hess, Jason R.

    1995-01-01

    The existing system for gathering and processing acoustical test data had several shortcomings and limitations in the areas of microphone array size, sampling rate, and background noise. A new Remote Acquisition and Storage System (RASS) is being designed for applications not suited for the existing acquisition system. One of the first tasks in the design of the RASS was to redesign the microprocessor card of the existing system to include RS-232 serial ports to accept communications through the radio modem used in the RF link. Cost and parts availability comparisons were made between the newly designed board and commercially available models, and a commercially made model was selected. This model was tested for basic I/0 operations. The prototype of the RF telemetry system was set up and tested. Plans are now being developed for integrating the RF telemetry system with the other RASS subsystems.

  12. Data Acquisition and Control Systems Laboratory

    NASA Technical Reports Server (NTRS)

    Holland, Randy; Jensen, Scott; Burrel, Terrence; Spooner, Richard

    2002-01-01

    The Data Acquisition and Control Systems (DACS) Laboratory is a facility at Stennis Space Center that provides an off test-stand capability to develop data-acquisition and control systems for rocket-engine test stands. It is also used to train new employees in state-of-the-art systems, and provides a controlled environment for troubleshooting existing systems, as well as the ability to evaluate the application of new technologies and process improvements. With the SSC propulsion testing schedules, without the DACS Laboratory, it would have been necessary to perform most of the development work on actual test systems, thereby subjecting both the rocket-engine testing and development programs to substantial interference in the form of delays, restrictions on modifications of equipment, and potentially compromising software configuration control. The DACS Laboratory contains a versatile assortment of computer hardware and software, digital and analog electronic control and data-acquisition equipment, and standard electronic bench test equipment and tools. Recently completed Control System development and software verification projects include support to the joint NASA/Air Force Integrated Powerhead Demonstration (IPD) LOX & LH2 PreBurner and Turbopump ground testing programs. In other recent activities, the DACS Laboratory equipment and expertise have supported the off-stand operation of high-pressure control valves to correct valve leak problems prior to installation on the test stand. Future plans include expanding the Laboratory's capabilities to provide cryogenic control valve characterization prior to installation, thereby reducing test stand activation time.

  13. Local Technical Resources for Development of Seismic Monitoring in Caucasus and Central Asia - GMSys2009 Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Chkhaidze, D.; Basilaia, G.; Elashvili, M.; Shishlov, D.; Bidzinashvili, G.

    2012-12-01

    Caucasus and Central Asia represents regions of high seismic activity, composing a significant part of Alpine-Himalayan continental collision zone. Natural catastrophic events cause significant damage to the infrastructure worldwide, among these approximately ninety percent of the annual loss is due to earthquakes. Monitoring of Seismic Activity in these regions and adequate assessment of Seismic Hazards represents indispensible condition for safe and stable development. Existence of critical engineering constructions in the Caucasus and Central Asia such as oil and gas pipelines, high dams and nuclear power plants dramatically raises risks associated with natural hazards and eliminates necessity of proper monitoring systems. Our initial efforts were focused on areas that we are most familiar; the geophysical community in the greater Caucuses and Central Asia experiencing many of the same problems with the monitoring equipment. As a result, during the past years GMSys2009 was develop at the Institute of Earth Sciences of Ilia State University. Equipment represents a cost-effective, multifunctional Geophysical Data Acquisition System (DAS) to monitor seismic waves propagating in the earth and related geophysical parameters. Equipment best fits local requirements concerning power management, environmental protection and functionality, the same time competing commercial units available on the market. During past several years more than 30 units were assembled and what is most important installed in Georgia, Armenia, Azerbaijan and Tajikistan. GMSys2009 utilizes standard MiniSEED data format and data transmission protocols, making it possible online waveform data sharing between the neighboring Countries in the region and international community. All the mentioned installations were technically supported by the group of engineers from the Institute of Earth Sciences, on site trainings for local personnel in Armenia, Azerbaijan and Tajikistan was provided creating a

  14. A Description of the Development, Capabilities, and Operational Status of the Test SLATE Data Acquisition System at the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Cramer, Christopher J.; Wright, James D.; Simmons, Scott A.; Bobbitt, Lynn E.; DeMoss, Joshua A.

    2015-01-01

    The paper will present a brief background of the previous data acquisition system at the National Transonic Facility (NTF) and the reasoning and goals behind the upgrade to the current Test SLATE (Test Software Laboratory and Automated Testing Environments) data acquisition system. The components, performance characteristics, and layout of the Test SLATE system within the NTF control room will be discussed. The development, testing, and integration of Test SLATE within NTF operations will be detailed. The operational capabilities of the system will be outlined including: test setup, instrumentation calibration, automatic test sequencer setup, data recording, communication between data and facility control systems, real time display monitoring, and data reduction. The current operational status of the Test SLATE system and its performance during recent NTF testing will be highlighted including high-speed, frame-by-frame data acquisition with conditional sampling post-processing applied. The paper concludes with current development work on the system including the capability for real-time conditional sampling during data acquisition and further efficiency enhancements to the wind tunnel testing process.

  15. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor,Bryant D.; Shams, Qamar A.; Fox, Robert L.

    2007-01-01

    This paper presents a measurement acquisition method that alleviates many shortcomings of traditional measurement systems. The shortcomings are a finite number of measurement channels, weight penalty associated with measurements, electrical arcing, wire degradations due to wear or chemical decay and the logistics needed to add new sensors. Wire degradation has resulted in aircraft fatalities and critical space launches being delayed. The key to this method is the use of sensors designed as passive inductor-capacitor circuits that produce magnetic field responses. The response attributes correspond to states of physical properties for which the sensors measure. Power is wirelessly provided to the sensing element by using Faraday induction. A radio frequency antenna produces a time-varying magnetic field used to power the sensor and receive the magnetic field response of the sensor. An interrogation system for discerning changes in the sensor response frequency, resistance and amplitude has been developed and is presented herein. Multiple sensors can be interrogated using this method. The method eliminates the need for a data acquisition channel dedicated to each sensor. The method does not require the sensors to be near the acquisition hardware. Methods of developing magnetic field response sensors and the influence of key parameters on measurement acquisition are discussed. Examples of magnetic field response sensors and the respective measurement characterizations are presented. Implementation of this method on an aerospace system is discussed.

  16. Reconfigurable Embedded System for Electrocardiogram Acquisition.

    PubMed

    Kay, Marcel Seiji; Iaione, Fábio

    2015-01-01

    Smartphones include features that offers the chance to develop mobile systems in medical field, resulting in an area called mobile-health. One of the most common medical examinations is the electrocardiogram (ECG), which allows the diagnosis of various heart diseases, leading to preventative measures and preventing more serious problems. The objective of this study was to develop a wireless reconfigurable embedded system using a FPAA (Field Programmable Analog Array), for the acquisition of ECG signals, and an application showing and storing these signals on Android smartphones. The application also performs the partial FPAA reconfiguration in real time (adjustable gain). Previous studies using FPAA usually use the development boards provided by the manufacturer (high cost), do not allow the reconfiguration in real time, use no smartphone and communicate via cables. The parameters tested in the acquisition circuit and the quality of ECGs registered in an individual were satisfactory. PMID:26262018

  17. Acquisition systems for heat transfer measurement

    SciTech Connect

    De Witt, R.J.

    1983-01-01

    Practical heat transfer data acquisition systems are normally characterized by the need for high-resolution, low-drift, low-speed recording devices. Analog devices such as strip chart or circular recorders and FM analog magnetic tape have excellent resolution and work well when data will be presented in temperature versus time format only and need not be processed further. Digital systems are more complex and require an understanding of the following components: digitizing devices, interface bus types, processor requirements, and software design. This paper discusses all the above components of analog and digital data acquisition, as they are used in current practice. Additional information on thermocouple system analysis will aid the user in developing accurate heat transfer measuring systems.

  18. Development of a Transformation System for Chlamydia trachomatis: Restoration of Glycogen Biosynthesis by Acquisition of a Plasmid Shuttle Vector

    PubMed Central

    Wang, Yibing; Kahane, Simona; Cutcliffe, Lesley T.; Skilton, Rachel J.; Lambden, Paul R.; Clarke, Ian N.

    2011-01-01

    Chlamydia trachomatis remains one of the few major human pathogens for which there is no transformation system. C. trachomatis has a unique obligate intracellular developmental cycle. The extracellular infectious elementary body (EB) is an infectious, electron-dense structure that, following host cell infection, differentiates into a non-infectious replicative form known as a reticulate body (RB). Host cells infected by C. trachomatis that are treated with penicillin are not lysed because this antibiotic prevents the maturation of RBs into EBs. Instead the RBs fail to divide although DNA replication continues. We have exploited these observations to develop a transformation protocol based on expression of β-lactamase that utilizes rescue from the penicillin-induced phenotype. We constructed a vector which carries both the chlamydial endogenous plasmid and an E.coli plasmid origin of replication so that it can shuttle between these two bacterial recipients. The vector, when introduced into C. trachomatis L2 under selection conditions, cures the endogenous chlamydial plasmid. We have shown that foreign promoters operate in vivo in C. trachomatis and that active β-lactamase and chloramphenicol acetyl transferase are expressed. To demonstrate the technology we have isolated chlamydial transformants that express the green fluorescent protein (GFP). As proof of principle, we have shown that manipulation of chlamydial biochemistry is possible by transformation of a plasmid-free C. trachomatis recipient strain. The acquisition of the plasmid restores the ability of the plasmid-free C. trachomatis to synthesise and accumulate glycogen within inclusions. These findings pave the way for a comprehensive genetic study on chlamydial gene function that has hitherto not been possible. Application of this technology avoids the use of therapeutic antibiotics and therefore the procedures do not require high level containment and will allow the analysis of genome function by

  19. Development of a transformation system for Chlamydia trachomatis: restoration of glycogen biosynthesis by acquisition of a plasmid shuttle vector.

    PubMed

    Wang, Yibing; Kahane, Simona; Cutcliffe, Lesley T; Skilton, Rachel J; Lambden, Paul R; Clarke, Ian N

    2011-09-01

    Chlamydia trachomatis remains one of the few major human pathogens for which there is no transformation system. C. trachomatis has a unique obligate intracellular developmental cycle. The extracellular infectious elementary body (EB) is an infectious, electron-dense structure that, following host cell infection, differentiates into a non-infectious replicative form known as a reticulate body (RB). Host cells infected by C. trachomatis that are treated with penicillin are not lysed because this antibiotic prevents the maturation of RBs into EBs. Instead the RBs fail to divide although DNA replication continues. We have exploited these observations to develop a transformation protocol based on expression of β-lactamase that utilizes rescue from the penicillin-induced phenotype. We constructed a vector which carries both the chlamydial endogenous plasmid and an E.coli plasmid origin of replication so that it can shuttle between these two bacterial recipients. The vector, when introduced into C. trachomatis L2 under selection conditions, cures the endogenous chlamydial plasmid. We have shown that foreign promoters operate in vivo in C. trachomatis and that active β-lactamase and chloramphenicol acetyl transferase are expressed. To demonstrate the technology we have isolated chlamydial transformants that express the green fluorescent protein (GFP). As proof of principle, we have shown that manipulation of chlamydial biochemistry is possible by transformation of a plasmid-free C. trachomatis recipient strain. The acquisition of the plasmid restores the ability of the plasmid-free C. trachomatis to synthesise and accumulate glycogen within inclusions. These findings pave the way for a comprehensive genetic study on chlamydial gene function that has hitherto not been possible. Application of this technology avoids the use of therapeutic antibiotics and therefore the procedures do not require high level containment and will allow the analysis of genome function by

  20. TARA control, data acquisition and analysis system

    SciTech Connect

    Gaudreau, M.P.J.; Sullivan, J.D.; Fredian, T.W.; Karcher, C.A.; Sevillano, E.; Stillerman, J.; Thomas, P.

    1983-12-01

    The MIT tandem mirror (TARA) control, data acquisition and analysis system consists of two major parts: (1) a Gould 584 industrial programmable controller (PC) to control engineering functions; and (2) a VAX 11/750 based data acquisition and analysis system for physics analysis. The PC is designed for use in harsh industrial environments and has proven to be a reliable and cost-effective means for automated control. The PC configuration is dedicated to control tasks on the TARA magnet, vacuum, RF, neutral beam, diagnostics, and utility systems. The data transfer functions are used to download system operating parameters from menu selectable tables. Real time status reports are provided to video terminals and as blocks of data to the host computer for storage. The data acquisition and analysis system for TARA was designed to provide high throughput and ready access to data from earlier runs. The adopted design uses pre-existing software packages in a system which is simple, coherent, fast, and which requires a minimum of new software development. The computer configuration is a VAX 11/750 running VMS with 124 M byte massbus disk and 1.4 G byte unibus disk subsystem.

  1. Open, reconfigurable cytometric acquisition system: ORCAS.

    PubMed

    Naivar, Mark A; Parson, Jimmie D; Wilder, Mark E; Habbersett, Robert C; Edwards, Bruce S; Sklar, Larry; Nolan, John P; Graves, Steven W; Martin, John C; Jett, James H; Freyer, James P

    2007-11-01

    A digital signal processing (DSP)-based digital data acquisition system has been developed to support novel flow cytometry efforts. The system flexibility includes how it detects, captures, and processes event data. Custom data capture boards utilizing analog to digital converters (ADCs) and field programmable gate arrays (FPGA) detect events and capture correlated event data. A commercial DSP board processes the captured data and sends the results over the IEEE 1394 bus to the host computer that provides a user interface for acquisition, display, analysis, and storage. The system collects list mode data, correlated pulse shapes, or streaming data from a variety of detector types using Linux, Mac OS X, and Windows host computers. It extracts pulse features not found on commercial systems with excellent sensitivity and linearity over a wide dynamic range. List mode data are saved in FCS 3.0 formatted files while streaming or correlated waveform data are saved in custom format files for postprocessing. Open, reconfigurable cytometric acquisition system is compact, scaleable, flexible, and modular. Programmable feature extraction algorithms have exciting possibilities for both new and existing applications. The recent availability of a commercial data capture board will enable general availability of similar systems. PMID:17680705

  2. CEBAF Distributed Data Acquisition System

    SciTech Connect

    Trent Allison; Thomas Powers

    2005-05-01

    There are thousands of signals distributed throughout Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) that are useful for troubleshooting and identifying instabilities. Many of these signals are only available locally or monitored by systems with small bandwidths that cannot identify fast transients. The Distributed Data Acquisition (Dist DAQ) system will sample and record these signals simultaneously at rates up to 40 Msps. Its primary function will be to provide waveform records from signals throughout CEBAF to the Experimental Physics and Industrial Control System (EPICS). The waveforms will be collected after the occurrence of an event trigger. These triggers will be derived from signals such as periodic timers or accelerator faults. The waveform data can then be processed to quickly identify beam transport issues, thus reducing down time and increasing CEBAF performance. The Dist DAQ system will be comprised of multiple standalone chassis distributed throughout CEBAF. They will be interconnected via a fiber optic network to facilitate the global triggering of events. All of the chassis will also be connected directly to the CEBAF Ethernet and run EPICS locally. This allows for more flexibility than the typical configuration of a single board computer and other custom printed circuit boards (PCB) installed in a card cage.

  3. Wavelets for full reconfigurable ECG acquisition system

    NASA Astrophysics Data System (ADS)

    Morales, D. P.; García, A.; Castillo, E.; Meyer-Baese, U.; Palma, A. J.

    2011-06-01

    This paper presents the use of wavelet cores for a full reconfigurable electrocardiogram signal (ECG) acquisition system. The system is compound by two reconfigurable devices, a FPGA and a FPAA. The FPAA is in charge of the ECG signal acquisition, since this device is a versatile and reconfigurable analog front-end for biosignals. The FPGA is in charge of FPAA configuration, digital signal processing and information extraction such as heart beat rate and others. Wavelet analysis has become a powerful tool for ECG signal processing since it perfectly fits ECG signal shape. The use of these cores has been integrated in the LabVIEW FPGA module development tool that makes possible to employ VHDL cores within the usual LabVIEW graphical programming environment, thus freeing the designer from tedious and time consuming design of communication interfaces. This enables rapid test and graphical representation of results.

  4. MSG-SEVIRI and EOS-MODIS LST Product Validation by Using a Developed Thermal-Infrared Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Niclòs, Raquel; Valiente, José Antonio; Jesús Barberà, María; Sánchez, Juan Manuel

    2014-05-01

    Multidirectional thermal infrared (TIR) measurements are convenient to describe the radiative characteristics of natural surfaces and to obtain accurate Land Surface Temperature (LST). An autonomous system for field angular thermal-infrared (TIR) radiometric data acquisition was developed with the aim of being easily deployed at any traditional meteorological tower station. The device scans land and sky hemispheres at several angular steps to attain remotely sensed land and sky temperatures by means of a single infrared radiometer. Apogee radiometers were selected to be included in the prototype not only by their reduced size and easy functioning but also by their measurement accuracies as proved in calibrations against NIST blackbodies (± 0.2 K at 293-303 K). During the 2012 summer, a prototype of the device was deployed at an extensive, homogeneous and flat cultivated-rice area widely used in experimental CAL/VAL campaigns of satellite TIR sensors (39.274°N, -0.317°E in WGS-84; 2.5 m above sea level). The measured TIR data were processed to obtain ground-truth LST and compared with the operational LST products provided by two satellite TIR instruments: MODIS on board EOS-Terra and EOS-Aqua platforms and SEVIRI on board of the geostationary MSG. Both the MSG-SEVIRI and the EOS-MODIS LST products were shown to work with uncertainties within those expected, but a general overestimation was observed for the MSG-SEVIRI product (with a median between product and ground LST data of + 0.6 K and a robust standard deviation (RSD) of ± 1.0K) and a slight underestimation, especially for off-nadir observation angles, was observed for the EOS-MODIS LST product (i.e., a median of -0.10 K and a RSD of ± 1.2K for all the MODIS-viewing angles, but a median of -0.7 K and a RSD of ± 1.5 K for angles larger than 40°). Satellite LST product validation will be extended by using data collected by the autonomous and angular system setup at different sites in Eastern Spain. This

  5. Jefferson Lab Data Acquisition Run Control System

    SciTech Connect

    Vardan Gyurjyan; Carl Timmer; David Abbott; William Heyes; Edward Jastrzembski; David Lawrence; Elliott Wolin

    2004-10-01

    A general overview of the Jefferson Lab data acquisition run control system is presented. This run control system is designed to operate the configuration, control, and monitoring of all Jefferson Lab experiments. It controls data-taking activities by coordinating the operation of DAQ sub-systems, online software components and third-party software such as external slow control systems. The main, unique feature which sets this system apart from conventional systems is its incorporation of intelligent agent concepts. Intelligent agents are autonomous programs which interact with each other through certain protocols on a peer-to-peer level. In this case, the protocols and standards used come from the domain-independent Foundation for Intelligent Physical Agents (FIPA), and the implementation used is the Java Agent Development Framework (JADE). A lightweight, XML/RDF-based language was developed to standardize the description of the run control system for configuration purposes.

  6. New-generation data acquisition and control system for continuum radio-astronomic observations with RATAN-600 radio telescope: Development, observations, and measurements

    NASA Astrophysics Data System (ADS)

    Tsybulev, P. G.

    2011-01-01

    A new Data Acquisition and Control System for performing continuum radio-astronomical observations with the RATAN-600 radio telescope is presented. One of the "building blocks" of the system is the Embedded Radiometric Data Acquisition System (ER-DAS) developed at the RATAN-600. It is a measurement facility meant for digitizing and reducing radiometer signals and for transmitting the result of these operations via Ethernet networks. ER-DAS system is shown to have a low self-noise level and to lack 1/ f-type noise. The measurement facility is shown to operate efficiently in radio-astronomical observations. Radiometric measurements of the parameters of high-sensitivity radiometers are illustrated in the case of the measurements of radiometer gain fluctuations.

  7. Multiple channel data acquisition system

    DOEpatents

    Crawley, H. Bert; Rosenberg, Eli I.; Meyer, W. Thomas; Gorbics, Mark S.; Thomas, William D.; McKay, Roy L.; Homer, Jr., John F.

    1990-05-22

    A multiple channel data acquisition system for the transfer of large amounts of data from a multiplicity of data channels has a plurality of modules which operate in parallel to convert analog signals to digital data and transfer that data to a communications host via a FASTBUS. Each module has a plurality of submodules which include a front end buffer (FEB) connected to input circuitry having an analog to digital converter with cache memory for each of a plurality of channels. The submodules are interfaced with the FASTBUS via a FASTBUS coupler which controls a module bus and a module memory. The system is triggered to effect rapid parallel data samplings which are stored to the cache memories. The cache memories are uploaded to the FEBs during which zero suppression occurs. The data in the FEBs is reformatted and compressed by a local processor during transfer to the module memory. The FASTBUS coupler is used by the communications host to upload the compressed and formatted data from the module memory. The local processor executes programs which are downloaded to the module memory through the FASTBUS coupler.

  8. Multiple channel data acquisition system

    DOEpatents

    Crawley, H.B.; Rosenberg, E.I.; Meyer, W.T.; Gorbics, M.S.; Thomas, W.D.; McKay, R.L.; Homer, J.F. Jr.

    1990-05-22

    A multiple channel data acquisition system for the transfer of large amounts of data from a multiplicity of data channels has a plurality of modules which operate in parallel to convert analog signals to digital data and transfer that data to a communications host via a FASTBUS. Each module has a plurality of submodules which include a front end buffer (FEB) connected to input circuitry having an analog to digital converter with cache memory for each of a plurality of channels. The submodules are interfaced with the FASTBUS via a FASTBUS coupler which controls a module bus and a module memory. The system is triggered to effect rapid parallel data samplings which are stored to the cache memories. The cache memories are uploaded to the FEBs during which zero suppression occurs. The data in the FEBs is reformatted and compressed by a local processor during transfer to the module memory. The FASTBUS coupler is used by the communications host to upload the compressed and formatted data from the module memory. The local processor executes programs which are downloaded to the module memory through the FASTBUS coupler. 25 figs.

  9. Modeling of the DZero data acquisition system

    SciTech Connect

    Angstadt, R.; Johnson, M. Manning, I.L. ); Wightman, J.A. . Dept. of Physics)

    1992-08-01

    A queuing theory model was used in the initial design of the DZero data acquisition system. It was mainly used for the front end electronic systems. Since then the model has been extended to include the entire data path for the tracking system. The tracking system generates the most data so we expect this system to determine the overall transfer rate. The model was developed using both analytical and simulation methods for solving a series of single server queues. This paper describes the model and the methods used to develop it. The authors present results form the original models, updated calculations representing the system as built and comparisons with measurements made with the hardware in place for the cosmic ray test run.

  10. Modeling of the DZero data acquisition system

    SciTech Connect

    Angstadt, R.; Johnson, M.; Manning, I.L.; Wightman, J.A. |

    1991-12-01

    A queuing theory model was used in the initial design of the D0 data acquisition system. It was mainly used for the front end electronic systems. Since then the model has been extended to include the entire data path for the tracking system. The tracking system generates the most data so we expect this system to determine the overall transfer rate. The model was developed using both analytical and simulation methods for solving a series of single server queues. We describe the model and the methods used to develop it. We also present results from the original models, updated calculations representing the system as built and comparisons with measurements made with the hardware in place for the cosmic ray test run. 3 refs.

  11. Increasingly automated procedure acquisition in dynamic systems

    NASA Technical Reports Server (NTRS)

    Mathe, Nathalie; Kedar, Smadar

    1992-01-01

    Procedures are widely used by operators for controlling complex dynamic systems. Currently, most development of such procedures is done manually, consuming a large amount of paper, time, and manpower in the process. While automated knowledge acquisition is an active field of research, not much attention has been paid to the problem of computer-assisted acquisition and refinement of complex procedures for dynamic systems. The Procedure Acquisition for Reactive Control Assistant (PARC), which is designed to assist users in more systematically and automatically encoding and refining complex procedures. PARC is able to elicit knowledge interactively from the user during operation of the dynamic system. We categorize procedure refinement into two stages: diagnosis - diagnose the failure and choose a repair - and repair - plan and perform the repair. The basic approach taken in PARC is to assist the user in all steps of this process by providing increased levels of assistance with layered tools. We illustrate the operation of PARC in refining procedures for the control of a robot arm.

  12. Miniature infrared data acquisition and telemetry system

    NASA Technical Reports Server (NTRS)

    Stokes, J. H.; Ward, S. M.

    1985-01-01

    The Miniature Infrared Data Acquisition and Telemetry (MIRDAT) Phase 1 study was performed to determine the technical and commercial feasibility of producing a miniaturized electro-optical telemetry system. This system acquires and transmits experimental data from aircraft scale models for realtime monitoring in wind tunnels. During the Phase 1 study, miniature prototype MIRDAT telemetry devices were constructed, successfully tested in the laboratory and delivered to the user for wind tunnel testing. A search was conducted for commercially available components and advanced hybrid techniques to further miniaturize the system during Phase 2 development. A design specification was generated from laboratory testing, user requirements and discussions with component manufacturers. Finally, a preliminary design of the proposed MIRDAT system was documented for Phase 2 development.

  13. Design and development of an automated, portable and handheld tablet personal computer-based data acquisition system for monitoring electromyography signals during rehabilitation.

    PubMed

    Ahamed, Nizam U; Sundaraj, Kenneth; Poo, Tarn S

    2013-03-01

    This article describes the design of a robust, inexpensive, easy-to-use, small, and portable online electromyography acquisition system for monitoring electromyography signals during rehabilitation. This single-channel (one-muscle) system was connected via the universal serial bus port to a programmable Windows operating system handheld tablet personal computer for storage and analysis of the data by the end user. The raw electromyography signals were amplified in order to convert them to an observable scale. The inherent noise of 50 Hz (Malaysia) from power lines electromagnetic interference was then eliminated using a single-hybrid IC notch filter. These signals were sampled by a signal processing module and converted into 24-bit digital data. An algorithm was developed and programmed to transmit the digital data to the computer, where it was reassembled and displayed in the computer using software. Finally, the following device was furnished with the graphical user interface to display the online muscle strength streaming signal in a handheld tablet personal computer. This battery-operated system was tested on the biceps brachii muscles of 20 healthy subjects, and the results were compared to those obtained with a commercial single-channel (one-muscle) electromyography acquisition system. The results obtained using the developed device when compared to those obtained from a commercially available physiological signal monitoring system for activities involving muscle contractions were found to be comparable (the comparison of various statistical parameters) between male and female subjects. In addition, the key advantage of this developed system over the conventional desktop personal computer-based acquisition systems is its portability due to the use of a tablet personal computer in which the results are accessible graphically as well as stored in text (comma-separated value) form. PMID:23662342

  14. Collection Development/Acquisitions: Collaboration or Conflict?

    ERIC Educational Resources Information Center

    Clement, Mercedes

    At the Daytona Beach Community College (DBCC) Library, collection development, selection, and acquisitions function as levels of a hierarchy. The highest level is collection development, which constitutes the planning function. Meetings are held annually to assess user needs, evaluate the present collection, discuss budget considerations, plan for…

  15. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a...

  16. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a...

  17. 48 CFR 1401.7001-4 - Acquisition performance measurement systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Acquisition performance measurement systems. 1401.7001-4 Section 1401.7001-4 Federal Acquisition Regulations System DEPARTMENT OF THE... Acquisition performance measurement systems. (a) The acquisition performance measurement system is a...

  18. SSC/BCD data acquisition system proposal

    SciTech Connect

    Barsotti, E.; Bowden, M.; Swoboda, C.

    1989-04-01

    The proposed new data acquisition system architecture takes event fragments off a detector over fiber optics and to a parallel event building switch. The parallel event building switch concept, taken from the telephone communications industry, along with expected technology improvements in fiber-optic data transmission speeds over the next few years, should allow data acquisition system rates to increase dramatically and exceed those rates needed for the SSC. This report briefly describes the switch architecture and fiber optics for a SSC data acquisition system.

  19. Thermal (Silicon Diode) Data Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Wright, Ernest; Kegley, Jeff

    2008-01-01

    Marshall Space Flight Center s X-ray Cryogenic Facility (XRCF) has been performing cryogenic testing to 20 Kelvin since 1999. Two configurations for acquiring data from silicon diode temperature sensors have been implemented at the facility. The facility's environment is recorded via a data acquisition system capable of reading up to 60 silicon diodes. Test article temperature is recorded by a second data acquisition system capable of reading 150+ silicon diodes. The specifications and architecture of both systems will be presented.

  20. Thermal (Silicon Diode) Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey

    2008-01-01

    Marshall Space Flight Center's X-ray Calibration Facility (XRCF) has been performing cryogenic testing to 20 Kelvin since 1999. Two configurations for acquiring data from silicon diode temperature sensors have been implemented at the facility. The facility's environment is recorded via a data acquisition system capable of reading up to 60 silicon diodes. Test article temperature is recorded by a second data acquisition system capable of reading 150+ silicon diodes. The specifications and architecture of both systems will be presented.

  1. Scalable multichannel MRI data acquisition system.

    PubMed

    Bodurka, Jerzy; Ledden, Patrick J; van Gelderen, Peter; Chu, Renxin; de Zwart, Jacco A; Morris, Doug; Duyn, Jeff H

    2004-01-01

    A scalable multichannel digital MRI receiver system was designed to achieve high bandwidth echo-planar imaging (EPI) acquisitions for applications such as BOLD-fMRI. The modular system design allows for easy extension to an arbitrary number of channels. A 16-channel receiver was developed and integrated with a General Electric (GE) Signa 3T VH/3 clinical scanner. Receiver performance was evaluated on phantoms and human volunteers using a custom-built 16-element receive-only brain surface coil array. At an output bandwidth of 1 MHz, a 100% acquisition duty cycle was achieved. Overall system noise figure and dynamic range were better than 0.85 dB and 84 dB, respectively. During repetitive EPI scanning on phantoms, the relative temporal standard deviation of the image intensity time-course was below 0.2%. As compared to the product birdcage head coil, 16-channel reception with the custom array yielded a nearly 6-fold SNR gain in the cerebral cortex and a 1.8-fold SNR gain in the center of the brain. The excellent system stability combined with the increased sensitivity and SENSE capabilities of 16-channel coils are expected to significantly benefit and enhance fMRI applications. PMID:14705057

  2. The use of machine learning program LERS-LB 2.5 in knowledge acquisition for expert system development in nursing.

    PubMed

    Woolery, L; Grzymala-Busse, J; Summers, S; Budihardjo, A

    1991-01-01

    LERS-LB (Learning from Examples using Rough Sets Lower Boundaries) is a computer program based on rough set theory for knowledge acquisition, which extracts patterns from real-world data in generating production rules for expert system development. From LERS-LB evaluation of an SPSS-X data file containing data for recovery room patients, it was concluded that both statistical data files and existing databases can be converted to decision-table format needed by LERS-LB, but it is less desirable to work with statistical files than a well-developed database. It was also concluded that choosing a well-developed database and checking it thoroughly for accuracy and completeness should be done before running LERS-LB, or other learning programs, to avoid problems with data errors. Using rough set theory and a technique called 'dropping conditions' LERS-LB offers, at least in theory, a possible method for identifying which data items are critical to nursing practice. Further research and continued LERS-LB program enhancements still may help with identifying critical data items versus redundant data for nursing practice. LERS-LB, and other learning programs, offer techniques which will help reduce the knowledge acquisition bottleneck in nursing expert system development. It is doubtful, however, that learning programs will eliminate the need for involving domain experts in evaluating rules and expert systems for clinical decision support. PMID:1747822

  3. 48 CFR 27.406-3 - Major system acquisition.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Major system acquisition. 27.406-3 Section 27.406-3 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... Major system acquisition. (a) The clause at 52.227-21, Technical Data Declaration, Revision,...

  4. Bagless Transfer System Welder Data Acquisition Software

    SciTech Connect

    Collins, Susan L.

    2003-09-30

    The Bagless Transfer System Welder Data Acquisition Software (BTS DAS) was developed by SRTC to replace a strip chart recorder that has been in place since the design of the BTS. During the welding process, critical weld parameters such as weld current and voltage, can give valuable information about the weld. In the past, weld data from the TID welding process, has been monitored using strip chart recorders. The data from the weld process, recorded on the strip chart recorder traces, are reviewed to analyze the weld. The BTS DAS improves this technology by digitizing the weld data which allows for automation of the analysis process. Also, the data files are now stored digitally as well as a hard copy printout, so they can be reanalyzed if needed. The BTS DAS performs the necessary functions to perform the data acquisition functions during the BTS Welding Process. It is important to monitor the critical weld parameters, current and voltage, during a weld as they can be used to set acceptance criteria for weld acceptance. The software monitors and records the weld current, voltage, and RPM data. The welder DAS is a passive device and does not control the welder. The BTS control system interfaces directly with the welder and the BTS DAS. Digital handshaking is used between the BTS DAS and the BTS control system to ensure that the DAS is ready to weld prior to allowing the operator to initiate the welding process.

  5. Bagless Transfer System Welder Data Acquisition Software

    2003-09-30

    The Bagless Transfer System Welder Data Acquisition Software (BTS DAS) was developed by SRTC to replace a strip chart recorder that has been in place since the design of the BTS. During the welding process, critical weld parameters such as weld current and voltage, can give valuable information about the weld. In the past, weld data from the TID welding process, has been monitored using strip chart recorders. The data from the weld process, recordedmore » on the strip chart recorder traces, are reviewed to analyze the weld. The BTS DAS improves this technology by digitizing the weld data which allows for automation of the analysis process. Also, the data files are now stored digitally as well as a hard copy printout, so they can be reanalyzed if needed. The BTS DAS performs the necessary functions to perform the data acquisition functions during the BTS Welding Process. It is important to monitor the critical weld parameters, current and voltage, during a weld as they can be used to set acceptance criteria for weld acceptance. The software monitors and records the weld current, voltage, and RPM data. The welder DAS is a passive device and does not control the welder. The BTS control system interfaces directly with the welder and the BTS DAS. Digital handshaking is used between the BTS DAS and the BTS control system to ensure that the DAS is ready to weld prior to allowing the operator to initiate the welding process.« less

  6. Control And Data Acquisition System Of Tokamak KTM

    SciTech Connect

    Baystrukov, K. I.; Pavlov, V. M.; Sharnin, A. V.; Obhodskij, A. V.; Merkulov, S. V.; Golobokov, Y. N.; Mezentsev, A. A.; Ovchinnikov, A. V.; Tazhibaeva, I. L.

    2008-04-07

    The preliminary results of control and data acquisition system (CODAS) development for Kazakhstan tokamak for material testing (KTM) [1] are presented. The KTM CODAS is completely new system optimized for KTM facility and its regimes of operation. Its development is carrying out in Tomsk Polytechnic University by Russian specialists. The first KTM launching under the control of CODAS is planed on 2008 year. The base functionality of CODAS is presented, including short description of its subsystems, such as control system of conditioning process, plasma control system, digital control system of power supplies, protection and timing system, data acquisition system.

  7. Strategic petroleum reserve data acquisition system

    SciTech Connect

    Merillat, P D; Bauer, A G

    1980-10-01

    The Strategic Petroleum Reserve Data Acquisition System is a general purpose, digital data acquisition system designed for field use in the DOE's Strategic Petroleum Reserve testing and monitoring program. The system is computer driven, under the control of an operator. The system is designed to allow the operator to perform pre-test system configuration; test monitoring and control; and post test analysis. This document is a system description and an operator users manual. Topics covered include: configuration and running on-line tests, software documentation, and maintenance programming information.

  8. 48 CFR 470.202 - Acquisition of commodities for United States Agency for International Development (USAID) programs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 4 2011-10-01 2011-10-01 false Acquisition of commodities for United States Agency for International Development (USAID) programs. 470.202 Section 470.202 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE FOOD ASSISTANCE PROGRAMS COMMODITY ACQUISITIONS 470.202 Acquisition of commodities...

  9. Optical image acquisition system for colony analysis

    NASA Astrophysics Data System (ADS)

    Wang, Weixing; Jin, Wenbiao

    2006-02-01

    For counting of both colonies and plaques, there is a large number of applications including food, dairy, beverages, hygiene, environmental monitoring, water, toxicology, sterility testing, AMES testing, pharmaceuticals, paints, sterile fluids and fungal contamination. Recently, many researchers and developers have made efforts for this kind of systems. By investigation, some existing systems have some problems since they belong to a new technology product. One of the main problems is image acquisition. In order to acquire colony images with good quality, an illumination box was constructed as: the box includes front lightning and back lightning, which can be selected by users based on properties of colony dishes. With the illumination box, lightning can be uniform; colony dish can be put in the same place every time, which make image processing easy. A digital camera in the top of the box connected to a PC computer with a USB cable, all the camera functions are controlled by the computer.

  10. Measurement and Controls Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Hall, Rick; Daniel, Alice; Batts, Frank E., Sr.

    2006-01-01

    Measurement and Controls Data Acquisition System (MCDAS) is an application program that integrates the functions of two stand-alone programs: one for acquisition of data, the other for controls. MCDAS facilitates and improves testing of complex engineering systems by helping to perform calibration and setup of test systems and acquisition, dissemination, and processing of data. Features of MCDAS include an intuitive, user-friendly graphical user interface, a capability for acquiring data at rates greater than previously possible, cooperation between the data-acquisition software subsystem and alarm-checking and analytical components of the control software subsystem, and a capability for dissemination of data through fiber optics and virtual and wide-area networks, including networks that contain hand-held display units. The integration of the data acquisition and control software offers a safety advantage by making alarm information available to the control software in a more timely manner. By enabling the use of hand-held devices, MCDAS reduces the time spent by technicians asking for screen updates to determine effects of setup actions. Previously recorded data can be processed without interruption to current acquisition of data. Analysts can continue to view test parameters while test-data files are being generated.

  11. Performance confirmation data acquisition system

    SciTech Connect

    McAffee, D.A.; Raczka, N.T.

    1997-12-31

    As part of the Viability Assessment (VA) work, this QAP-3-9 document presents and evaluates a comprehensive set of viable concepts for collecting Performance Confirmation (PC) related data. The concepts include: monitoring subsurface repository air temperatures, humidity levels and gaseous emissions via the subsurface ventilation systems, and monitoring the repository geo-technical parameters and rock mass from bore-holes located along the perimeter main drifts and throughout a series of human-rated Observation Drifts to be located in a plane 25 meters above the plane of the emplacement drifts. A key element of this document is the development and analysis of a purposed multi-purpose Remote Inspection Gantry that would provide direct, real-time visual, thermal, and radiological monitoring of conditions inside operational emplacement drifts and close-up observations of in-situ Waste Packages. Preliminary finite-element analyses are presented that indicate the technological feasibility of operating an inspection gantry inside the operational emplacement drifts for short inspection missions lasting 2--3 hours. Overall reliability, availability, and maintainability of the PC data collection concepts are discussed. Preliminary concepts for PC data collection network are also provided.

  12. DAQMAN - A flexible configurable data acquisition system

    SciTech Connect

    Sivertz, Michael; Larry Hoff, Seth Nemesure

    2012-08-01

    DAQMAN is a flexible configurable interface that allows the user to build and operate a VME-based data acquisition system on a Linux workstation. It consists of two parts: a Java-based Graphical User Interface to configure the system, and a C-based utility that reads out the data and creates the output ASCII data file, with two levels of diagnostic tools. The data acquisition system requires a CAEN CONET-VME Bridge to communicate between the hardware in the VME crate and the Linux workstation. Data acquisition modules, such as ADCs, TDC, Scalers, can be loaded into the system, or removed easily. The GUI allows users to activate modules, and channels within modules by clicking on icons. Running configurations are stored; data are collected and can be viewed either as raw numbers, or by charts and histograms that update as the data are accumulated. Data files are written to disk in ASCII format, with a date and time stamp.

  13. Development of an AutoFlat program for the acquisition of effective flat images in the automated observation system

    NASA Astrophysics Data System (ADS)

    Yoon, Joh-Na; Kim, Yonggi; Kim, Dong-Heun; Yim, Hong-Suh

    2013-12-01

    The purpose of this study is to develop an observation program for obtaining effective flat images that are necessary for photometric observation. The development of the program was achieved by improving the existing method for obtaining twilight flat images. The existing method for obtaining twilight flat images acquires flat images by observing the sky light after sunset or light before sunrise. The decision of when to observe flat images at each night is solely dependent on the judgment of an observer, and thus the obtained flat images for particular nights may not be clean. Especially, in the case of the observatories where an automated observation system is in operation, there is a difficulty that an observer should pay attention during sunrise and sunset in order to obtain flat images. In this study, a computer program is developed to improve this inconvenience and to efficiently perform photometric observation in the observatories where an automated observation system is applied. This program can obtain flat images by calculating the time for obtaining flat images automatically and the exposure time using a numerically calculated function. When obtaining twilight flat images at dusk and at dawn, the developed program performs automated observation and provides effective flat images by acquiring appropriate exposure time considering the sunrise and sunset times that vary depending on the day of observation. The code for performing this task was added to Obs Tool II (Yoon et al. 2006), which is the automated observation system of the Chungbuk National University Observatory, and the usefulness of the developed program was examined by performing an actual automated observation. If this program is applied to other observatories where automated observation is in operation, it is expected that stable and highquality flat images could be obtained, which can be used for the pre-processing of photometric observation data.

  14. Infrared Mueller matrix acquisition and preprocessing system.

    PubMed

    Carrieri, Arthur H; Owens, David J; Schultz, Jonathan C

    2008-09-20

    An analog Mueller matrix acquisition and preprocessing system (AMMS) was developed for a photopolarimetric-based sensor with 9.1-12.0 microm optical bandwidth, which is the middle infrared wavelength-tunable region of sensor transmitter and "fingerprint" spectral band for chemical-biological (analyte) standoff detection. AMMS facilitates delivery of two alternate polarization-modulated CO(2) laser beams onto subject analyte that excite/relax molecular vibrational resonance in its analytic mass, primes the photoelastic-modulation engine of the sensor, establishes optimum throughput radiance per backscattering cross section, acquires Mueller elements modulo two laser beams in hexadecimal format, preprocesses (normalize, subtract, filter) these data, and formats the results into digitized identification metrics. Feed forwarding of formatted Mueller matrix metrics through an optimally trained and validated neural network provides pattern recognition and type classification of interrogated analyte. PMID:18806864

  15. Knowledge acquisition for autonomous systems

    NASA Technical Reports Server (NTRS)

    Lum, Henry; Heer, Ewald

    1988-01-01

    Knowledge-based capabilities for autonomous aerospace systems, such as the NASA Space Station, must encompass conflict-resolution functions comparable to those of human operators, with all elements of the system working toward system goals in a concurrent, asynchronous-but-coordinated fashion. Knowledge extracted from a design database will support robotic systems by furnishing geometric, structural, and causal descriptions required for repair, disassembly, and assembly. The factual knowledge for these databases will be obtained from a master database through a technical management information system, and it will in many cases have to be augmented by domain-specific heuristic knowledge acquired from domain experts.

  16. A digital imaging photometry system for cometary data acquisition

    NASA Technical Reports Server (NTRS)

    Clifton, K. S.; Benson, C. M.; Gary, G. A.

    1986-01-01

    This report describes a digital imaging photometry system developed in the Space Science Laboratory at the Marshall Space Flight center. The photometric system used for cometary data acquisition is based on an intensified secondary electron conduction (ISEC) vidicon coupled to a versatile data acquisition system which allows real-time interactive operation. Field tests on the Orion and Rosette nebulas indicate a limiting magnitude of approximately m sub v = 14 over the 40 arcmin field-of-view. Observations were conducted of Comet Giacobini-Zinner in August 1985. The resulting data are discussed in relation to the capabilities of the digital analysis system. The development program concluded on August 31, 1985.

  17. A Fully Implantable 96-channel Neural Data Acquisition System

    PubMed Central

    Rizk, Michael; Bossetti, Chad A; Jochum, Thomas A; Callender, Stephen H; Nicolelis, Miguel A L; Turner, Dennis A; Wolf, Patrick D

    2009-01-01

    A fully implantable neural data acquisition system is a key component of a clinically viable brain-machine interface. This type of system must communicate with the outside world and obtain power without the use of wires that cross through the skin. We present a 96-channel fully implantable neural data acquisition system. This system performs spike detection and extraction within the body and wirelessly transmits data to an external unit. Power is supplied wirelessly through the use of inductively-coupled coils. The system was implanted acutely in sheep and successfully recorded, processed, and transmitted neural data. Bidirectional communication between the implanted system and an external unit was successful over a range of 2 m. The system is also shown to integrate well into a brain-machine interface. This demonstration of a high channel-count fully implanted neural data acquisition system is a critical step in the development of a clinically viable brain-machine interface. PMID:19255459

  18. The data acquisition system for SLD

    SciTech Connect

    Sherden, D.J.

    1986-10-01

    This paper describes the data acquisition system planned for the SLD detector, which is being constructed for use with the SLAC Linear Collider (SLC). Analog electronics, heavily incorporating hybrid and custom VLSI circuitry, is mounted on the detector itself. Extensive use is made of multiplexing through optical fibers to a FASTBUS readout system. The low repetition rate of the SLC allows a relatively simple software-based trigger. Hardware and software processors within the acquisition modules are used to reduce the large volume of data per event and to calibrate the electronics. A farm of microprocessors is used for full reconstruction of a sample of events prior to transmission to the host.

  19. The data acquisition system for SLD

    SciTech Connect

    Sherden, D.J.

    1987-04-01

    This paper describes the data acquisition system planned for the SLD detector, which is being constructed for use with the SLAC Linear Collider (SLC). Analog electronics, heavily incorporating hybrid and custom VLSI circuitry, is mounted on the detector itself. Extensive use is made of multiplexing through optical fibers to a FASTBUS readout system. The low repetition rate of the SLC allows a relatively simple software-based trigger. Hardware and software processors within the acquisition modules are used to reduce the large volume of data per event and to calibrate the electronics. A farm of microprocessors is used for full reconstruction of a sample of events prior to transmission to the host.

  20. Acquisition and display systems of FTV (free-viewpoint television)

    NASA Astrophysics Data System (ADS)

    Fujii, Toshiaki; Tanimoto, Masayuki

    2003-11-01

    Free-viewpoint TeleVision (FTV) is a next generation television where users can move their viewpoints freely. In the previous paper, we reported an FTV system based on the Ray-Space representation. In this paper, we focus on acquisition and display system for the FTV. As an acquisition system, we investigated two configurations: (1) multiple cameras with interpolation, and (2) a single high-speed camera with optical scanning system. As a display system, we developed a display with head tracking, where the position of a user is detected by image processing.

  1. Knowledge-Acquisition Tool For Expert System

    NASA Technical Reports Server (NTRS)

    Disbrow, James D.; Duke, Eugene L.; Regenie, Victoria A.

    1988-01-01

    Digital flight-control systems monitored by computer program that evaluates and recommends. Flight-systems engineers for advanced, high-performance aircraft use knowlege-acquisition tool for expert-system flight-status monitor suppling interpretative data. Interpretative function especially important in time-critical, high-stress situations because it facilitates problem identification and corrective strategy. Conditions evaluated and recommendations made by ground-based engineers having essential knowledge for analysis and monitoring of performances of advanced aircraft systems.

  2. Driver performance data acquisition system for ergonomics research

    SciTech Connect

    Carter, R.J.; Goodman, M.J.

    1994-12-31

    A portable ergonomics data acquisition system consisting of state-of-the-art hardware being designed is described here. It will be employed to record driver, vehicle, and environment parameter data from a wide range of vehicles and trucks. The system will be unobtrusive to the driver and inconspicuous to the outside world. It will have three modes of data gathering and provide for extended periods of data collection. Modularity, flexibility, and cost will be key drivers in the development effort. The ergonomics data acquisition system project is being conducted in two phases--a feasibility study and a development, construction, and validation phase.

  3. Cardiopulmonary data-acquisition system

    NASA Technical Reports Server (NTRS)

    Crosier, W. G.; Reed, R. A.

    1981-01-01

    Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.

  4. The Yersinia pestis Siderophore, Yersiniabactin, and the ZnuABC system both contribute to Zinc acquisition and the development of lethal septicemic plague in mice

    PubMed Central

    Bobrov, Alexander G.; Kirillina, Olga; Fetherston, Jacqueline D.; Miller, M. Clarke; Burlison, Joseph A.; Perry, Robert D.

    2014-01-01

    Summary Bacterial pathogens must overcome host sequestration of zinc (Zn2+), an essential micronutrient, during the infectious disease process. While the mechanisms to acquire chelated Zn2+ by bacteria are largely undefined, many pathogens rely upon the ZnuABC family of ABC transporters. Here we show that in Yersinia pestis, irp2, a gene encoding the synthetase (HMWP2) for the siderophore yersiniabactin (Ybt) is required for growth under Zn2+-deficient conditions in a strain lacking ZnuABC. Moreover, growth stimulation with exogenous, purified apo-Ybt provides evidence that Ybt may serve as a zincophore for Zn2+ acquisition. Studies with the Zn2+-dependent transcriptional reporter znuA∷lacZ indicate that the ability to synthesize Ybt affects the levels of intracellular Zn2+. However, the outer membrane receptor Psn and TonB as well as the inner membrane (IM) ABC transporter YbtPQ, that are required for Fe3+ acquisition by Ybt, are not needed for Ybt-dependent Zn2+ uptake. In contrast, the predicted IM protein YbtX, a member of the Major Facilitator Superfamily, was essential for Ybt-dependent Zn2+ uptake. Finally, we show that the ZnuABC system and the Ybt synthetase HMWP2, presumably by Ybt synthesis, both contribute to the development of a lethal infection in a septicemic plague mouse model. PMID:24979062

  5. 7 CFR 1980.340 - Acquisition, construction, and development.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 14 2010-01-01 2009-01-01 true Acquisition, construction, and development. 1980.340... Acquisition, construction, and development. (a) Acquisition of property. The Lender is responsible for seeing... paragraph IV C of exhibit D of subpart A of part 1924. (c) Development. The Lender and borrower...

  6. 7 CFR 1980.340 - Acquisition, construction, and development.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 14 2011-01-01 2011-01-01 false Acquisition, construction, and development. 1980.340... Acquisition, construction, and development. (a) Acquisition of property. The Lender is responsible for seeing... paragraph IV C of exhibit D of subpart A of part 1924. (c) Development. The Lender and borrower...

  7. 7 CFR 1980.340 - Acquisition, construction, and development.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 14 2012-01-01 2012-01-01 false Acquisition, construction, and development. 1980.340... Acquisition, construction, and development. (a) Acquisition of property. The Lender is responsible for seeing... paragraph IV C of exhibit D of subpart A of part 1924. (c) Development. The Lender and borrower...

  8. 7 CFR 1980.340 - Acquisition, construction, and development.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 14 2014-01-01 2014-01-01 false Acquisition, construction, and development. 1980.340... Acquisition, construction, and development. (a) Acquisition of property. The Lender is responsible for seeing... paragraph IV C of exhibit D of subpart A of part 1924. (c) Development. The Lender and borrower...

  9. 7 CFR 1980.340 - Acquisition, construction, and development.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 14 2013-01-01 2013-01-01 false Acquisition, construction, and development. 1980.340... Acquisition, construction, and development. (a) Acquisition of property. The Lender is responsible for seeing... paragraph IV C of exhibit D of subpart A of part 1924. (c) Development. The Lender and borrower...

  10. Precision cryogenic temperature data acquisition system

    NASA Astrophysics Data System (ADS)

    Farah, Y.; Sondericker, J. H.

    1985-08-01

    A Multiplexed Temperature Data Acquisition System with an overall precision of + or - 25 ppM has been designed using state-of-the-art electronics to accurately read temperature between 2.4 K and 600 K from pre-calibrated transducers such as germanium, silicon diode, thermistor or platinum temperature sensors.

  11. An intelligent data acquisition system for fluid mechanics research

    NASA Technical Reports Server (NTRS)

    Cantwell, E. R.; Zilliac, G.; Fukunishi, Y.

    1989-01-01

    This paper describes a novel data acquisition system for use with wind-tunnel probe-based measurements, which incorporates a degree of specific fluid dynamics knowledge into a simple expert system-like control program. The concept was developed with a rudimentary expert system coupled to a probe positioning mechanism operating in a small-scale research wind tunnel. The software consisted of two basic elements, a general-purpose data acquisition system and the rulebased control element to take and analyze data and supplying decisions as to where to measure, how many data points to take, and when to stop. The system was validated in an experiment involving a vortical flow field, showing that it was possible to increase the resolution of the experiment or, alternatively, reduce the total number of data points required, to achieve parity with the results of most conventional data acquisition approaches.

  12. The CDMS II data acquisition system

    SciTech Connect

    Bauer, D.A.; Burke, S.; Cooley, J.; Crisler, M.; Cushman, P.; DeJongh, F.; Duong, L.; Ferril, R.; Golwala, S.R.; Hall, J.; Holmgren, D.; /Fermilab /Texas A-M

    2011-01-01

    The Data Acquisition System for the CDMS II dark matter experiment was designed and built when the experiment moved to its new underground installation at the Soudan Lab. The combination of remote operation and increased data load necessitated a completely new design. Elements of the original LabView system remained as stand-alone diagnostic programs, but the main data processing moved to a VME-based system with custom electronics for signal conditioning, trigger formation and buffering. The data rate was increased 100-fold and the automated cryogenic system was linked to the data acquisition. A modular server framework with associated user interfaces was implemented in Java to allow control and monitoring of the entire experiment remotely.

  13. An accelerated forth data-acquisition system

    NASA Technical Reports Server (NTRS)

    Bowhill, S. A.; Rennier, A. D.

    1986-01-01

    A new data acquisition system was put into operation at Urbana in August 1984. It uses a standard Apple 2 microcomputer with 48 k RAM and a standard 5 1/4 inch floppy disk. Design criteria for the system is given. The system was implemented using fig-FORTH, a threaded interpretive language which permits easy interfacing to machine code. The throughput of this system is better by a factor of 6 than the PDP-15 minicomputer system previously used, and it has the real time display feature and provides the data in much more convenient form. The features which contribute to this improved performance is listed.

  14. Optoelectronic date acquisition system based on FPGA

    NASA Astrophysics Data System (ADS)

    Li, Xin; Liu, Chunyang; Song, De; Tong, Zhiguo; Liu, Xiangqing

    2015-11-01

    An optoelectronic date acquisition system is designed based on FPGA. FPGA chip that is EP1C3T144C8 of Cyclone devices from Altera corporation is used as the centre of logic control, XTP2046 chip is used as A/D converter, host computer that communicates with the date acquisition system through RS-232 serial communication interface are used as display device and photo resistance is used as photo sensor. We use Verilog HDL to write logic control code about FPGA. It is proved that timing sequence is correct through the simulation of ModelSim. Test results indicate that this system meets the design requirement, has fast response and stable operation by actual hardware circuit test.

  15. Isothermal thermogravimetric data acquisition analysis system

    NASA Technical Reports Server (NTRS)

    Cooper, Kenneth, Jr.

    1991-01-01

    The description of an Isothermal Thermogravimetric Analysis (TGA) Data Acquisition System is presented. The system consists of software and hardware to perform a wide variety of TGA experiments. The software is written in ANSI C using Borland's Turbo C++. The hardware consists of a 486/25 MHz machine with a Capital Equipment Corp. IEEE488 interface card. The interface is to a Hewlett Packard 3497A data acquisition system using two analog input cards and a digital actuator card. The system provides for 16 TGA rigs with weight and temperature measurements from each rig. Data collection is conducted in three phases. Acquisition is done at a rapid rate during initial startup, at a slower rate during extended data collection periods, and finally at a fast rate during shutdown. Parameters controlling the rate and duration of each phase are user programmable. Furnace control (raising and lowering) is also programmable. Provision is made for automatic restart in the event of power failure or other abnormal terminations. Initial trial runs were conducted to show system stability.

  16. DAQMAN - A flexible configurable data acquisition system

    2012-08-01

    DAQMAN is a flexible configurable interface that allows the user to build and operate a VME-based data acquisition system on a Linux workstation. It consists of two parts: a Java-based Graphical User Interface to configure the system, and a C-based utility that reads out the data and creates the output ASCII data file, with two levels of diagnostic tools. The data acquisition system requires a CAEN CONET-VME Bridge to communicate between the hardware in themore » VME crate and the Linux workstation. Data acquisition modules, such as ADCs, TDC, Scalers, can be loaded into the system, or removed easily. The GUI allows users to activate modules, and channels within modules by clicking on icons. Running configurations are stored; data are collected and can be viewed either as raw numbers, or by charts and histograms that update as the data are accumulated. Data files are written to disk in ASCII format, with a date and time stamp.« less

  17. A WBAN based cableless ECG acquisition system.

    PubMed

    Pan, Rui; Chua, Dingjuan; Pathmasuntharam, Jaya Shankar; Xu, Yong Ping

    2014-01-01

    A Wireless Body Area Network (WBAN) based 3-lead cableless electrocardiography (ECG) acquisition system is described. To enable truly cableless ECG monitoring, a new ECG measurement configuration and method that acquires ECG signals at individual lead locations referenced to a localized ground is proposed. The synthesized ECG signals are evaluated against the standard wired 3-lead configuration on the same test subject. Average Pearson correlation coefficients of 0.82, 0.95 and 0.86 have been achieved for Lead I, II and III signals respectively, demonstrating a high degree of similarity in the synthesized signals. Measurements are obtained via a custom wireless network platform utilizing a TDMA-based MAC protocol supporting the star topology and a proprietary front-end ECG acquisition system. PMID:25570107

  18. Smart data acquisition system for utilities metering

    NASA Astrophysics Data System (ADS)

    Ileana, I.; Risteiu, M.; Tulbure, A.; Rusu, M.

    2009-01-01

    The paper approaches the task of automatically reading and recognition of registered data on the utility meters of the users and is a part of a more complex project of our team concerning the remote data acquisition from industrial processes. A huge amount of utility meters in our country is of mechanical type without remote acquiring facilities and as an intermediate solution we propose an intelligent optical acquisition system which will store the read values in desktop and mobile devices. The main requirements of such a system are: portability, data reading accuracy, fast processing and energy independence. The paper analyses several solutions (including Artificial Neural Networks approach) tested by our team and present the experimental results and our conclusions.

  19. Evaluating Student-Teacher Linkage Data in Teacher Incentive Fund (TIF) Sites: Acquisition, Verification, and System Development. The Harvesting Project

    ERIC Educational Resources Information Center

    Watson, Jeffery; Witham, Peter; St. Louis, Timothy

    2010-01-01

    The U.S. Department of Education Teacher Incentive Fund (TIF) seeks to transform education compensation systems so that principal and teacher performance (measured through classroom productivity measures) connects to compensation. Classroom-level productivity measures require robust student-teacher linkage data. Organizations such as the…

  20. The HyperCP data acquisition system

    SciTech Connect

    Kaplan, D.M.; E871 Collaboration

    1997-06-01

    For the HyperCP experiment at Fermilab, we have assembled a data acquisition system that records on up to 45 Exabyte 8505 tape drives in parallel at up to 17 MB/s. During the beam spill, data are acquired from the front-end digitization systems at {approx} 60 MB/s via five parallel data paths. The front-end systems achieve typical readout deadtime of {approx} 1 {micro}s per event, allowing operation at 75-kHz trigger rate with {approx_lt}30% deadtime. Event building and tapewriting are handled by 15 Motorola MVME167 processors in 5 VME crates.

  1. Major system acquisitions process (A-109)

    NASA Technical Reports Server (NTRS)

    Saric, C.

    1991-01-01

    The Major System examined is a combination of elements (hardware, software, facilities, and services) that function together to produce capabilities required to fulfill a mission need. The system acquisition process is a sequence of activities beginning with documentation of mission need and ending with introduction of major system into operational use or otherwise successful achievement of program objectives. It is concluded that the A-109 process makes sense and provides a systematic, integrated management approach along with appropriate management level involvement and innovative and 'best ideas' from private sector in satisfying mission needs.

  2. Embedded data acquisition system for neutron monitors

    NASA Astrophysics Data System (ADS)

    Población, Ó. G.; Blanco, J. J.; Gómez-Herrero, R.; Steigies, C. T.; Medina, J.; Tejedor, I. G.; Sánchez, S.

    2014-08-01

    This article presents the design and implementation of a new data acquisition system to be used as replacement for the old ones that have been in use with neutron monitors for the last decades and, which are eventually becoming obsolete. This new system is also intended to be used in new installations, enabling these scientific instruments to use today's communication networks to send data and receive commands from the operators. This system is currently running in two stations: KIEL2, in the Christian-Albrechts-Universität zu Kiel, Kiel, Germany, and CALMA, in the Castilla-La Mancha Neutron Monitor, Guadalajara, Spain.

  3. Small parachute flight data acquisition system

    SciTech Connect

    Ryerson, D.E.; Hauser, G.C.

    1989-01-01

    Sandia National Laboratories does extensive parachute design and testing. In support of that work, Sandia's Telemetry Department has designed and fielded a small, inexpensive data acquisition system. The system has been used in over fifty parachute and water entry tests. It consists of a microprocessor controlled unit which digitizes up to eight channels of signal-conditioned analog data and stores the data in memory for readout after the test. The system is also capable of doing control functions such as releasing the parachute at a predetermined time after unit release. 4 refs., 7 figs.

  4. Auxiliary DCP data acquisition system. [airborne system

    NASA Technical Reports Server (NTRS)

    Snyder, R. V.

    1975-01-01

    An airborne DCP Data Aquisition System has been designed to augment the ERTS satellite data recovery system. The DCP's are data collection platforms located at pertinent sites. With the appropriate sensors they are able to collect, digitally encode and transmit environmental parameters to the ERTS satellite. The satellite in turn relays these transmissions to a ground station for processing. The satellite is available for such relay duty a minimum of two times in a 24-hour period. The equipment is to obtain continuous DCP data during periods of unusual environmental activity--storms, floods, etc. Two circumstances contributed to the decision to design such a system; (1) Wallops Station utilizes surveillance aircraft in support of rocket launches and also in support of earth resources activities; (2) the area in which Wallops is located, the Delaware and Chesapeake Bay areas, are fertile areas for DCP usage. Therefore, by developing an airborne DCP receiving station and installing it on aircraft more continuous DCP data can be provided from sites in the surrounding areas at relatively low cost.

  5. The DECam data acquisition and control system

    NASA Astrophysics Data System (ADS)

    Honscheid, K.; Eiting, J.; Elliott, A.; Annis, J.; Bonati, M.; Buckley-Geer, E.; Castander, F.; da Costa, L.; Haney, M.; Hanlon, W.; Karliner, I.; Kuehn, K.; Kuhlmann, S.; Marshall, S.; Meyer, M.; Neilsen, E.; Ogando, R.; Roodman, A.; Schalk, T.; Schumacher, G.; Selen, M.; Serrano, S.; Thaler, J.; Wester, W.

    2010-07-01

    In this paper we describe the data acquisition and control system of the Dark Energy Camera (DECam), which will be the primary instrument used in the Dark Energy Survey (DES). DES is a high precision multibandpath wide area survey of 5000 square degrees of the southern sky. DECam currently under construction at Fermilab will be a 3 square degree mosaic camera mounted at the prime focus of the Blanco 4m telescope at the Cerro-Tololo International Observatory (CTIO). The DECam data acquisition system (SISPI) is implemented as a distributed multi-processor system with a software architecture built on the Client-Server and Publish-Subscribe design patterns. The underlying message passing protocol is based on PYRO, a powerful distributed object technology system written entirely in Python. A distributed shared variable system was added to support exchange of telemetry data and other information between different components of the system. In this paper we discuss the SISPI infrastructure software, the image pipeline, the observer interface and quality monitoring system, and the instrument control system.

  6. A simulation of data acquisition system for SSC experiments

    SciTech Connect

    Watase, Y.; Ikeda, H.

    1989-04-01

    A simulation on some parts of the data acquisition system was performed using a general purpose simulation language GPSS. Several results of the simulation are discussed for the data acquisition system for the SSC experiment.

  7. Magnetic Field Response Measurement Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E. (Inventor); Taylor, Bryant D. (Inventor); Shams, Qamar A. (Inventor); Fox, Robert L. (Inventor); Fox, Christopher L. (Inventor); Fox, Melanie L. (Inventor); Bryant, Robert G. (Inventor)

    2006-01-01

    Magnetic field response sensors designed as passive inductor-capacitor circuits produce magnetic field responses whose harmonic frequencies correspond to states of physical properties for which the sensors measure. Power to the sensing element is acquired using Faraday induction. A radio frequency antenna produces the time varying magnetic field used for powering the sensor, as well as receiving the magnetic field response of the sensor. An interrogation architecture for discerning changes in sensor s response kequency, resistance and amplitude is integral to the method thus enabling a variety of measurements. Multiple sensors can be interrogated using this method, thus eliminating the need to have a data acquisition channel dedicated to each sensor. The method does not require the sensors to be in proximity to any form of acquisition hardware. A vast array of sensors can be used as interchangeable parts in an overall sensing system.

  8. Automated data acquisition technology development:Automated modeling and control development

    NASA Technical Reports Server (NTRS)

    Romine, Peter L.

    1995-01-01

    This report documents the completion of, and improvements made to, the software developed for automated data acquisition and automated modeling and control development on the Texas Micro rackmounted PC's. This research was initiated because a need was identified by the Metal Processing Branch of NASA Marshall Space Flight Center for a mobile data acquisition and data analysis system, customized for welding measurement and calibration. Several hardware configurations were evaluated and a PC based system was chosen. The Welding Measurement System (WMS), is a dedicated instrument strickly for use of data acquisition and data analysis. In addition to the data acquisition functions described in this thesis, WMS also supports many functions associated with process control. The hardware and software requirements for an automated acquisition system for welding process parameters, welding equipment checkout, and welding process modeling were determined in 1992. From these recommendations, NASA purchased the necessary hardware and software. The new welding acquisition system is designed to collect welding parameter data and perform analysis to determine the voltage versus current arc-length relationship for VPPA welding. Once the results of this analysis are obtained, they can then be used to develop a RAIL function to control welding startup and shutdown without torch crashing.

  9. The wireless data acquisition system based on Bluetooth

    NASA Astrophysics Data System (ADS)

    Cheng, En; Xu, Xiao-na; Wu, Si-long

    2013-03-01

    Bluetooth is one of the wireless communication technology, which is developing rapidly in recent years. As a result of low cost and short distance, Bluetooth can set up a special connection for portable electronic devices and stationary electronic equipment communication environment. The paper studies a data acquisition system based on Bluetooth. The system can collect the angle of motor rotation and send it to the Receiver through the Bluetooth. The results show that the system can be run normal.[1

  10. Real-Time Wireless Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Valencia, Emilio J.; Perotti, Jose; Lucena, Angel; Mata, Carlos

    2007-01-01

    Current and future aerospace requirements demand the creation of a new breed of sensing devices, with emphasis on reduced weight, power consumption, and physical size. This new generation of sensors must possess a high degree of intelligence to provide critical data efficiently and in real-time. Intelligence will include self-calibration, self-health assessment, and pre-processing of raw data at the sensor level. Most of these features are already incorporated in the Wireless Sensors Network (SensorNet(TradeMark)), developed by the Instrumentation Group at Kennedy Space Center (KSC). A system based on the SensorNet(TradeMark) architecture consists of data collection point(s) called Central Stations (CS) and intelligent sensors called Remote Stations (RS) where one or more CSs can be accommodated depending on the specific application. The CS's major function is to establish communications with the Remote Stations and to poll each RS for data and health information. The CS also collects, stores and distributes these data to the appropriate systems requiring the information. The system has the ability to perform point-to-point, multi-point and relay mode communications with an autonomous self-diagnosis of each communications link. Upon detection of a communication failure, the system automatically reconfigures to establish new communication paths. These communication paths are automatically and autonomously selected as the best paths by the system based on the existing operating environment. The data acquisition system currently under development at KSC consists of the SensorNet(TradeMark) wireless sensors as the remote stations and the central station called the Radio Frequency Health Node (RFHN). The RFF1N is the central station which remotely communicates with the SensorNet(TradeMark) sensors to control them and to receive data. The system's salient feature is the ability to provide deterministic sensor data with accurate time stamps for both time critical and non

  11. Data acquisition and instrument control system for neutron spectrometers

    NASA Astrophysics Data System (ADS)

    Naik, S. S.; Kotwal, Ismat; Chandak, R. M.; Gaonkar, V. G.

    2004-08-01

    A personal computer (PC)-based data acquisition and instrument control system has been developed for neutron spectrometers in Dhruva reactor hall and Guide Tube laboratory. Efforts have been made to make the system versatile so that it can be used for controlling various neutron spectrometers using single end-on detector in step scan mode. Commercially available PC add-on cards have been used for input--output and timer-counter operations. An interface card and DC motor driver card have been developed indigenously. Software for the system has been written in Visual C++ language using MS Windows operating system. This data acquisition and instrument control system is successfully controlling four spectrometers at Dhruva reactor.

  12. Implementation of High Speed Distributed Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Raju, Anju P.; Sekhar, Ambika

    2012-09-01

    This paper introduces a high speed distributed data acquisition system based on a field programmable gate array (FPGA). The aim is to develop a "distributed" data acquisition interface. The development of instruments such as personal computers and engineering workstations based on "standard" platforms is the motivation behind this effort. Using standard platforms as the controlling unit allows independence in hardware from a particular vendor and hardware platform. The distributed approach also has advantages from a functional point of view: acquisition resources become available to multiple instruments; the acquisition front-end can be physically remote from the rest of the instrument. High speed data acquisition system transmits data faster to a remote computer system through Ethernet interface. The data is acquired through 16 analog input channels. The input data commands are multiplexed and digitized and then the data is stored in 1K buffer for each input channel. The main control unit in this design is the 16 bit processor implemented in the FPGA. This 16 bit processor is used to set up and initialize the data source and the Ethernet controller, as well as control the flow of data from the memory element to the NIC. Using this processor we can initialize and control the different configuration registers in the Ethernet controller in a easy manner. Then these data packets are sending to the remote PC through the Ethernet interface. The main advantages of the using FPGA as standard platform are its flexibility, low power consumption, short design duration, fast time to market, programmability and high density. The main advantages of using Ethernet controller AX88796 over others are its non PCI interface, the presence of embedded SRAM where transmit and reception buffers are located and high-performance SRAM-like interface. The paper introduces the implementation of the distributed data acquisition using FPGA by VHDL. The main advantages of this system are high

  13. AZ-101 Mixer Pump Demonstration Data Acquisition System and Gamma Cart Data Acquisition Control System Software Configuration Management Plan

    SciTech Connect

    WHITE, D.A.

    1999-12-29

    This Software Configuration Management Plan (SCMP) provides the instructions for change control of the AZ1101 Mixer Pump Demonstration Data Acquisition System (DAS) and the Sludge Mobilization Cart (Gamma Cart) Data Acquisition and Control System (DACS).

  14. Small multipurpose stored data acquisition system

    SciTech Connect

    Hauser, G.C.; Ryerson, D.E.

    1990-01-01

    Sandia National Laboratories Telemetry Department has designed and is fielding a small, inexpensive multipurpose stored data acquisition system in tests ranging from 6000 meters below the ocean surface in seafloor penetrators to 40,000 meters above sea level in gamma ray telescope balloons. The systems consists of a simple microprocessor-controlled unit which digitizes analog data stores the data in memory for readout after the test by a portable personal compute. The system has been used in over ninety tests consisting of parachute drops, water entry test, vehicle environmental monitoring, and seafloor penetration tests. Data typically recorded with the system are acceleration, strain, temperature, pressure, and angular velocity. The system is also capable of generating control functions such as parachute release. 5 refs., 6 figs.

  15. L-C Measurement Acquisition Method for Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Woodard, Stanley E.; Taylor, B. Douglas; Shams, Qamar A.; Fox, Robert L.

    2003-01-01

    This paper describes a measurement acquisition method for aerospace systems that eliminates the need for sensors to have physical connection to a power source (i.e., no lead wires) or to data acquisition equipment. Furthermore, the method does not require the sensors to be in proximity to any form of acquisition hardware. Multiple sensors can be interrogated using this method. The sensors consist of a capacitor, C(p), whose capacitance changes with changes to a physical property, p, electrically connected to an inductor, L. The method uses an antenna to broadcast electromagnetic energy that electrically excites one or more inductive-capacitive sensors via Faraday induction. This method facilitates measurements that were not previously possible because there was no practical means of providing power and data acquisition electrical connections to a sensor. Unlike traditional sensors, which measure only a single physical property, the manner in which the sensing element is interrogated simultaneously allows measurement of at least two unrelated physical properties (e.g., displacement rate and fluid level) by using each constituent of the L-C element. The key to using the method for aerospace applications is to increase the distance between the L-C elements and interrogating antenna; develop all key components to be non-obtrusive and to develop sensing elements that can easily be implemented. Techniques that have resulted in increased distance between antenna and sensor will be presented. Fluid-level measurements and pressure measurements using the acquisition method are demonstrated in the paper.

  16. Secure Video Surveillance System Acquisition Software

    SciTech Connect

    2009-12-04

    The SVSS Acquisition Software collects and displays video images from two cameras through a VPN, and store the images onto a collection controller. The software is configured to allow a user to enter a time window to display up to 2 1/2, hours of video review. The software collects images from the cameras at a rate of 1 image per second and automatically deletes images older than 3 hours. The software code operates in a linux environment and can be run in a virtual machine on Windows XP. The Sandia software integrates the different COTS software together to build the video review system.

  17. An Effective 3D Ear Acquisition System

    PubMed Central

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  18. Secure Video Surveillance System Acquisition Software

    2009-12-04

    The SVSS Acquisition Software collects and displays video images from two cameras through a VPN, and store the images onto a collection controller. The software is configured to allow a user to enter a time window to display up to 2 1/2, hours of video review. The software collects images from the cameras at a rate of 1 image per second and automatically deletes images older than 3 hours. The software code operates in amore » linux environment and can be run in a virtual machine on Windows XP. The Sandia software integrates the different COTS software together to build the video review system.« less

  19. INO prototype detector and data acquisition system

    NASA Astrophysics Data System (ADS)

    Behere, Anita; Bhatia, M. S.; Chandratre, V. B.; Datar, V. M.; Mukhopadhyay, P. K.; Jena, Satyajit; Viyogi, Y. P.; Bhattacharya, Sudeb; Saha, Satyajit; Bhide, Sarika; Kalmani, S. D.; Mondal, N. K.; Nagaraj, P.; Nagesh, B. K.; Rao, Shobha K.; Reddy, L. V.; Saraf, M.; Satyanarayana, B.; Shinde, R. R.; Upadhya, S. S.; Verma, P.; Biswas, Saikat; Chattopadhyay, Subhasish; Sarma, P. R.

    2009-05-01

    India-based Neutrino Observatory (INO) collaboration is proposing to build a 50 kton magnetised iron calorimetric (ICAL) detector in an underground laboratory to be located in South India. Glass resistive plate chambers (RPCs) of about 2 m×2 m in size will be used as active elements for the ICAL detector. As a first step towards building the ICAL detector, a 35 ton prototype of the same is being set up over ground to track cosmic muons. Design and construction details of the prototype detector and its data acquisition system will be discussed. Some of the preliminary results from the detector stack will also be highlighted.

  20. An Effective 3D Ear Acquisition System.

    PubMed

    Liu, Yahui; Lu, Guangming; Zhang, David

    2015-01-01

    The human ear is a new feature in biometrics that has several merits over the more common face, fingerprint and iris biometrics. It can be easily captured from a distance without a fully cooperative subject. Also, the ear has a relatively stable structure that does not change much with the age and facial expressions. In this paper, we present a novel method of 3D ear acquisition system by using triangulation imaging principle, and the experiment results show that this design is efficient and can be used for ear recognition. PMID:26061553

  1. Goddard Space Flight Center's Structural Dynamics Data Acquisition System

    NASA Technical Reports Server (NTRS)

    McLeod, Christopher

    2004-01-01

    Turnkey Commercial Off The Shelf (COTS) data acquisition systems typically perform well and meet most of the objectives of the manufacturer. The problem is that they seldom meet most of the objectives of the end user. The analysis software, if any, is unlikely to be tailored to the end users specific application; and there is seldom the chance of incorporating preferred algorithms to solve unique problems. Purchasing a customized system allows the end user to get a system tailored to the actual application, but the cost can be prohibitive. Once the system has been accepted, future changes come with a cost and response time that's often not workable. When it came time to replace the primary digital data acquisition system used in the Goddard Space Flight Center's Structural Dynamics Test Section, the decision was made to use a combination of COTS hardware and in-house developed software. The COTS hardware used is the DataMAX II Instrumentation Recorder built by R.C. Electronics Inc. and a desktop Pentium 4 computer system. The in-house software was developed using MATLAB from The MathWorks. This paper will describe the design and development of the new data acquisition and analysis system.

  2. Goddard Space Flight Center's Structural Dynamics Data Acquisition System

    NASA Technical Reports Server (NTRS)

    McLeod, Christopher

    2004-01-01

    Turnkey Commercial Off The Shelf (COTS) data acquisition systems typically perform well and meet most of the objectives of the manufacturer. The problem is that they seldom meet most of the objectives of the end user. The analysis software, if any, is unlikely to be tailored to the end users specific application; and there is seldom the chance of incorporating preferred algorithms to solve unique problems. Purchasing a customized system allows the end user to get a system tailored to the actual application, but the cost can be prohibitive. Once the system has been accepted, future changes come with a cost and response time that's often not workable. When it came time to replace the primary digital data acquisition system used in the Goddard Space Flight Center's Structural Dynamics Test Section, the decision was made to use a combination of COTS hardware and in-house developed software. The COTS hardware used is the DataMAX II Instrumentation Recorder built by R.C. Electronics Inc. and a desktop Pentium 4 computer system. The in-house software was developed using MATLAF3 from The Mathworks. This paper will describe the design and development of the new data acquisition and analysis system.

  3. Reducing acquisition risk through integrated systems of systems engineering

    NASA Astrophysics Data System (ADS)

    Gross, Andrew; Hobson, Brian; Bouwens, Christina

    2016-05-01

    In the fall of 2015, the Joint Staff J7 (JS J7) sponsored the Bold Quest (BQ) 15.2 event and conducted planning and coordination to combine this event into a joint event with the Army Warfighting Assessment (AWA) 16.1 sponsored by the U.S. Army. This multipurpose event combined a Joint/Coalition exercise (JS J7) with components of testing, training, and experimentation required by the Army. In support of Assistant Secretary of the Army for Acquisition, Logistics, and Technology (ASA(ALT)) System of Systems Engineering and Integration (SoSE&I), Always On-On Demand (AO-OD) used a system of systems (SoS) engineering approach to develop a live, virtual, constructive distributed environment (LVC-DE) to support risk mitigation utilizing this complex and challenging exercise environment for a system preparing to enter limited user test (LUT). AO-OD executed a requirements-based SoS engineering process starting with user needs and objectives from Army Integrated Air and Missile Defense (AIAMD), Patriot units, Coalition Intelligence, Surveillance and Reconnaissance (CISR), Focused End State 4 (FES4) Mission Command (MC) Interoperability with Unified Action Partners (UAP), and Mission Partner Environment (MPE) Integration and Training, Tactics and Procedures (TTP) assessment. The SoS engineering process decomposed the common operational, analytical, and technical requirements, while utilizing the Institute of Electrical and Electronics Engineers (IEEE) Distributed Simulation Engineering and Execution Process (DSEEP) to provide structured accountability for the integration and execution of the AO-OD LVC-DE. As a result of this process implementation, AO-OD successfully planned for, prepared, and executed a distributed simulation support environment that responsively satisfied user needs and objectives, demonstrating the viability of an LVC-DE environment to support multiple user objectives and support risk mitigation activities for systems in the acquisition process.

  4. An advanced data-acquisition system for wind energy projects

    SciTech Connect

    Simms, D.A. ); Cousineau, K.L. )

    1992-10-01

    NREL has subcontracted with Zond Systems, Inc. to develop an advanced data-acquisition system (ADAS) for wind energy projects. The ADAS can be used to simplify the process of making accurate measurements and analyzing. The system utilizes state-of-the-art electronics and telemetry to provide distributed multi-source, multi-channel data acquisition. Local stand-alone microprocessor-based data acquisition modules (DAMs) can be located near sources of measurement. These allow analog data values to be digitized close to the measurement source, thus eliminating the need for long data runs and slip rings. Signals from digital sensors and transducers can also be directly input to the local DAMS. A PC-based ground station is used to coordinate data transmission to and from all remote DAMS, display real-time values, archive data sets, and process and analyze results. The system is capable of acquiring synchronized time-series data from sensors and transducers under a variety of test configurations in an operational wind-park environment. Data acquisition needs of the wind industry differ significantly from those of most other technologies. Most conventional system designs do not handle data coming from multiple distributed sources, nor do they provide telemetry or the ability to mesh multiple incoming digital data streams. This paper describes the capabilities of the ADAS, and how its design and cost objectives are geared to meet anticipated US wind industry needs.

  5. Commissioning of the ALICE data acquisition system

    NASA Astrophysics Data System (ADS)

    Anticic, T.; Barroso, V.; Carena, F.; Carena, W.; Chapeland, S.; Cobanoglu, O.; Dénes, E.; Divià, R.; Fuchs, U.; Kiss, T.; Makhlyueva, I.; Ozok, F.; Roukoutakis, F.; Schossmaier, K.; Soós, C.; Vyvre, P. V.; Vergara, S.

    2008-07-01

    ALICE (A Large Ion Collider Experiment) is the heavy-ion detector designed to study the physics of strongly interacting matter and the quark-gluon plasma at the CERN Large Hadron Collider (LHC). A flexible, large bandwidth Data Acquisition System (DAQ) has been designed and deployed to collect sufficient statistics in the short running time foreseen per year for heavy ions and to accommodate very different requirements originated from the 18 sub-detectors. The Data Acquisition and Test Environment (DATE) is the software framework handling the data from the detector electronics up to the mass storage. This paper reviews the DAQ software and hardware architecture, including the latest features of the final design, such as the handling of the numerous calibration procedures in a common framework. We also discuss the large scale tests conducted on the real hardware to assess the standalone DAQ performances, its interfaces with the other online systems and the extensive commissioning performed in order to be ready for cosmics data taking scheduled to start in November 2007. The test protocols followed to integrate and validate each sub-detector with DAQ and Trigger hardware synchronized by the Experiment Control System are described. Finally, we give an overview of the experiment logbook, and some operational aspects of the deployment of our computing facilities. The implementation of a Transient Data Storage able to cope with the 1.25 GB/s recorded by the event-building machines and the data quality monitoring framework are covered in separate papers.

  6. The DISTO data acquisition system at SATURNE

    SciTech Connect

    Balestra, F.; Bedfer, Y.; Bertini, R.

    1998-06-01

    The DISTO collaboration has built a large-acceptance magnetic spectrometer designed to provide broad kinematic coverage of multiparticle final states produced in pp scattering. The spectrometer has been installed in the polarized proton beam of the Saturne accelerator in Saclay to study polarization observables in the {rvec p}p {yields} pK{sup +}{rvec Y} (Y = {Lambda}, {Sigma}{sup 0} or Y{sup *}) reaction and vector meson production ({psi}, {omega} and {rho}) in pp collisions. The data acquisition system is based on a VME 68030 CPU running the OS/9 operating system, housed in a single VME crate together with the CAMAC interface, the triple port ECL memories, and four RISC R3000 CPU. The digitization of signals from the detectors is made by PCOS III and FERA front-end electronics. Data of several events belonging to a single Saturne extraction are stored in VME triple-port ECL memories using a hardwired fast sequencer. The buffer, optionally filtered by the RISC R3000 CPU, is recorded on a DLT cassette by DAQ CPU using the on-board SCSI interface during the acceleration cycle. Two UNIX workstations are connected to the VME CPUs through a fast parallel bus and the Local Area Network. They analyze a subset of events for on-line monitoring. The data acquisition system is able to read and record 3,500 ev/burst in the present configuration with a dead time of 15%.

  7. Shigella Iron Acquisition Systems and their Regulation

    PubMed Central

    Wei, Yahan; Murphy, Erin R.

    2016-01-01

    Survival of Shigella within the host is strictly dependent on the ability of the pathogen to acquire essential nutrients, such as iron. As an innate immune defense against invading pathogens, the level of bio-available iron within the human host is maintained at exceeding low levels, by sequestration of the element within heme and other host iron-binding compounds. In response to sequestration mediated iron limitation, Shigella produce multiple iron-uptake systems that each function to facilitate the utilization of a specific host-associated source of nutrient iron. As a mechanism to balance the essential need for iron and the toxicity of the element when in excess, the production of bacterial iron acquisition systems is tightly regulated by a variety of molecular mechanisms. This review summarizes the current state of knowledge on the iron-uptake systems produced by Shigella species, their distribution within the genus, and the molecular mechanisms that regulate their production. PMID:26904516

  8. Instrumentation & Data Acquisition System (D AS) Engineer

    NASA Technical Reports Server (NTRS)

    Jackson, Markus Deon

    2015-01-01

    The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

  9. 75 FR 25161 - Defense Federal Acquisition Regulation Supplement; Presumption of Development at Private Expense

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... Acquisition Regulation Supplement; Presumption of Development at Private Expense AGENCY: Defense Acquisition... validation of a contractor's or subcontractor's asserted restrictions on technical data and computer software... the presumption of development at private expense for major systems; and section 815(a)(2) of the...

  10. CCD image data acquisition system for optical astronomy.

    NASA Astrophysics Data System (ADS)

    Bhat, P. N.; Patnaik, K.; Kembhavi, A. K.; Patnaik, A. R.; Prabhu, T. P.

    1990-11-01

    A complete image processing system based on a charge coupled device (CCD) has been developed at TIFR, Bombay, for use in optical astronomy. The system consists of a P-8600/B GEC CCD chip, a CCD controller, a VAX 11/725 mini-computer to carry out the image acquisition and display on a VS-11 monitor. All the necessary software and part of the hardware were developed locally, integrated together and installed at the Vainu Bappu Observatory at Kavalur. CCD as an imaging device and its advantages over the conventional photographic plate is briefly reviewed. The acquisition system is described in detail. The preliminary results are presented and the future research programme is outlined.

  11. Simulation Based Acquisition for NASA's Office of Exploration Systems

    NASA Technical Reports Server (NTRS)

    Hale, Joe

    2004-01-01

    In January 2004, President George W. Bush unveiled his vision for NASA to advance U.S. scientific, security, and economic interests through a robust space exploration program. This vision includes the goal to extend human presence across the solar system, starting with a human return to the Moon no later than 2020, in preparation for human exploration of Mars and other destinations. In response to this vision, NASA has created the Office of Exploration Systems (OExS) to develop the innovative technologies, knowledge, and infrastructures to explore and support decisions about human exploration destinations, including the development of a new Crew Exploration Vehicle (CEV). Within the OExS organization, NASA is implementing Simulation Based Acquisition (SBA), a robust Modeling & Simulation (M&S) environment integrated across all acquisition phases and programs/teams, to make the realization of the President s vision more certain. Executed properly, SBA will foster better informed, timelier, and more defensible decisions throughout the acquisition life cycle. By doing so, SBA will improve the quality of NASA systems and speed their development, at less cost and risk than would otherwise be the case. SBA is a comprehensive, Enterprise-wide endeavor that necessitates an evolved culture, a revised spiral acquisition process, and an infrastructure of advanced Information Technology (IT) capabilities. SBA encompasses all project phases (from requirements analysis and concept formulation through design, manufacture, training, and operations), professional disciplines, and activities that can benefit from employing SBA capabilities. SBA capabilities include: developing and assessing system concepts and designs; planning manufacturing, assembly, transport, and launch; training crews, maintainers, launch personnel, and controllers; planning and monitoring missions; responding to emergencies by evaluating effects and exploring solutions; and communicating across the OEx

  12. An integrated, multi-vendor distributed data acquisition system

    SciTech Connect

    Butner, D.N.; Drlik, M.; Meyer, W.H.; Moller, J.M.; Preckshot, G.G.

    1988-03-03

    A distributed data acquisition system that uses various computer hardware and software is being developed to support magnetic fusion experiments at Lawrence Livermore National Laboratory (LLNL). The experimental sequence of operations is controlled by a supervisory program, which coordinates software running on Digital Equipment Corporation (DEC) VAX computers, Hewlett-Packard (HP) UNIX-based workstations, and HP BASIC desktop computers. An interprocess communication system (IPCS) allows programs to communicate with one another in a standard manner regardless of program location in the network or of operating system and hardware differences. We discuss the design and implementation of this data acquisition system with particular emphasis on the coordination model and the IPCS. 5 refs., 3 figs.

  13. Nike Facility Diagnostics and Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Chan, Yung; Aglitskiy, Yefim; Karasik, Max; Kehne, David; Obenschain, Steve; Oh, Jaechul; Serlin, Victor; Weaver, Jim

    2013-10-01

    The Nike laser-target facility is a 56-beam krypton fluoride system that can deliver 2 to 3 kJ of laser energy at 248 nm onto targets inside a two meter diameter vacuum chamber. Nike is used to study physics and technology issues related to laser direct-drive ICF fusion, including hydrodynamic and laser-plasma instabilities, material behavior at extreme pressures, and optical and x-ray diagnostics for laser-heated targets. A suite of laser and target diagnostics are fielded on the Nike facility, including high-speed, high-resolution x-ray and visible imaging cameras, spectrometers and photo-detectors. A centrally-controlled, distributed computerized data acquisition system provides robust data management and near real-time analysis feedback capability during target shots. Work supported by DOE/NNSA.

  14. Multiple channel optical data acquisition system

    DOEpatents

    Fasching, G.E.; Goff, D.R.

    1985-02-22

    A multiple channel optical data acquisition system is provided in which a plurality of remote sensors monitoring specific process variable are interrogated by means of a single optical fiber connecting the remote station/sensors to a base station. The remote station/sensors derive all power from light transmitted through the fiber from the base station. Each station/sensor is individually accessed by means of a light modulated address code sent over the fiber. The remote station/sensors use a single light emitting diode to both send and receive light signals to communicate with the base station and provide power for the remote station. The system described can power at least 100 remote station/sensors over an optical fiber one mile in length.

  15. A middle man approach to knowledge acquisition in expert systems

    NASA Technical Reports Server (NTRS)

    Jordan, Janice A.; Lin, Min-Jin; Mayer, Richard J.; Sterle, Mark E.

    1990-01-01

    The Weed Control Advisor (WCA) is a robust expert system that has been successfully implemented on an IBM AT class microcomputer in CLIPS. The goal of the WCA was to demonstrate the feasibility of providing an economical, efficient, user friendly system through which Texas rice producers could obtain expert level knowledge regarding herbicide application for weed control. During the development phase of the WCA, an improved knowledge acquisition method which we call the Middle Man Approach (MMA) was applied to facilitate the communication process between the domain experts and the knowledge engineer. The MMA served to circumvent the problems associated with the more traditional forms of knowledge acquisition by placing the Middle Man, a semi-expert in the problem domain with some computer expertise, at the site of system development. The middle man was able to contribute to system development in two major ways. First, the Middle Man had experience working in rice production and could assume many of the responsibilities normally performed by the domain experts such as explaining the background of the problem domain and determining the important relations. Second, the Middle Man was familiar with computers and worked closely with the system developers to update the rules after the domain experts reviewed the prototype, contribute to the help menus and explanation portions of the expert system, conduct the testing that is required to insure that the expert system gives the expected results answer questions in a timely way, help the knowledge engineer structure the domain knowledge into a useable form, and provide insight into the end user's profile which helped in the development of the simple user friendly interface. The final results were not only that both time expended and costs were greatly reduced by using the MMA, but the quality of the system was improved. This papa will introduce the WCA system and then discuss traditional knowledge acquisition along with

  16. The ADIS advanced data acquisition, imaging, and storage system

    SciTech Connect

    Flaherty, J.W.

    1986-01-01

    The design and development of Automated Ultrasonic Scanning Systems (AUSS) by McDonnell Aircraft Company has provided the background for the development of the ADIS advanced data acquisition, imaging, and storage system. The ADIS provides state-of-the-art ultrasonic data processing and imaging features which can be utilized in both laboratory and production line composite evaluation applications. System features, such as, real-time imaging, instantaneous electronic rescanning, multitasking capability, histograms, and cross-sections, provide the tools necessary to inspect and evaluate composite parts quickly and consistently.

  17. The Dark Energy Camera Data Acquisition and Control System

    NASA Astrophysics Data System (ADS)

    Buckley-Geer, Elizabeth J.; Annis, J.; Bonati, M.; Eiting, J.; Elliot, A.; Haney, M.; Hanlon, W.; Honscheid, K.; Karliner, I.; Kuehn, K. W.; Kuhlmann, S. E.; Marshall, S.; Roodman, A. J.; Schalk, T.; Schumacher, G.; Thaler, J.; Wester, W.

    2011-01-01

    The Dark Energy Camera (DECam) data acquisition and control system is called the Survey Image System Process Integration (SISPI). Implemented as a distributed multi-processor system, SISPI consists of a set of processes that will coordinate and perform image acquisition and deliver images to the data management system for processing. Separate processes for instrument control, image building and analysis, image acquisition and observatory control are built on top of an infrastructure layer that provides message passing and communications. Additional system components include a flexible configuration system and the facility database. The command protocol is implemented in Python using a client-server design pattern derived from the SML and SCLN communications software developed at CTIO. A publish-subscribe model has been added to support the distribution of telemetry data and alarm messages. The design of the graphical user interfaces follows the Model-View-Controller approach to distinguish between the actual information and the graphical representation of the data. We will present the software architecture of the SISPI system and report on the current status of the project.

  18. Timing for distribution and interrupt control for the TOPAZ Data Acquisition System

    SciTech Connect

    Ikeda, H.; Enomoto, R.; Kawabata, S.; Yamauchi, M.; Imanishi, A.; Ishii, T.; Maruyama, K.; Masuda, H.; Okumo, H.; Ukai, K.

    1987-02-01

    In order to provide a standardized control for the data acquisition system for the TOPAZ detector, a Timing Server/Receiver scheme was developed. The entire system is under control of the Interrupt Control Section, which manages an integral operation of the data acquisition system in the FASTBUS environment.

  19. Run control techniques for the Fermilab DART data acquisition system

    SciTech Connect

    Oleynik, G.; Engelfried, J.; Mengel, L.

    1995-10-01

    DART is the high speed, Unix based data acquisition system being developed by the Fermilab Computing Division in collaboration with eight High Energy Physics Experiments. This paper describes DART run-control which implements flexible, distributed, extensible and portable paradigms for the control and monitoring of data acquisition systems. We discuss the unique and interesting aspects of the run-control - why we chose the concepts we did, the benefits we have seen from the choices we made, as well as our experiences in deploying and supporting it for experiments during their commissioning and sub-system testing phases. We emphasize the software and techniques we believe are extensible to future use, and potential future modifications and extensions for those we feel are not.

  20. FATIMA; A data acquisition system for medium scale experiments

    SciTech Connect

    Watzlawik, K.H.; Nellen, R.; Noll, T.; Karnadi, M.; Machner, H. )

    1992-04-01

    This paper discusses the data acquisition system FATIMA (Fera Amplitude and Time Multiparameter Analyzer) utilizing CAMAC, FERA and a VAX-Station, designed and built for nuclear physics experiments like subthreshold {pi}{sup 0}-production in Heavy Ion Collisions. The major features of the system are fast data readout of up to 352 ADCs and/or TDCs in conjunction with data reduction, event buffering, high speed data transfer and simple interfacing to any workstation. For on-line acquisition, recording and analysis of data as well as experiment control a modular program system was developed on VAX/VMS. Data analysis comprises on-line sort of real and pseudo channels and graphical representation of sorted data.

  1. Single transmission line data acquisition system

    DOEpatents

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  2. Design of propellant acquisition systems for advanced cryogenic space propulsion systems

    NASA Technical Reports Server (NTRS)

    Burge, G. W.; Blackmon, J. B.; Castle, J. N.

    1973-01-01

    This paper presents results of work conducted to expand the technology base and evolve practical propellant surface tension acquisition system designs for future cryogenic space vehicles. Surface tension screen device channel flow analysis and supporting tests showed that reasonable mesh sizes could provide the required retention performance. Integrated subsystem studies and development showed that practical and effective screen surface tension acquisition devices could be designed for typical applications, but that other interfacing feed subsystems are often constrained by the design of the particular acquisition device. These constraints may dominate the total feed system performance.

  3. System design of the METC automatic data acquisition and control system

    SciTech Connect

    Goff, D. R.; Armstrong, D. L.

    1982-02-01

    A system of computer programs and hardware was developed by the Instrumentation Branch of the Morgantown Energy Technology Center (METC) to provide data acquisition and control features for research projects at the site. The Automatic Data Acquisition and Control System (ADACS) has the capability of servicing up to eight individual projects simultaneously, providing data acquisition, data feedback, and process control where needed. Several novel software features - including a data table driven program, extensive feedback in real time, free format English commands, and high reliability - were incorporated to provide these functions.

  4. 48 CFR 470.202 - Acquisition of commodities for United States Agency for International Development (USAID) programs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 4 2012-10-01 2012-10-01 false Acquisition of commodities for United States Agency for International Development (USAID) programs. 470.202 Section 470.202 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE FOOD ASSISTANCE PROGRAMS...

  5. 48 CFR 470.202 - Acquisition of commodities for United States Agency for International Development (USAID) programs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 4 2013-10-01 2013-10-01 false Acquisition of commodities for United States Agency for International Development (USAID) programs. 470.202 Section 470.202 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE FOOD ASSISTANCE PROGRAMS...

  6. 48 CFR 470.202 - Acquisition of commodities for United States Agency for International Development (USAID) programs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Acquisition of commodities for United States Agency for International Development (USAID) programs. 470.202 Section 470.202 Federal Acquisition Regulations System DEPARTMENT OF AGRICULTURE FOOD ASSISTANCE PROGRAMS...

  7. Advanced Video Data-Acquisition System For Flight Research

    NASA Technical Reports Server (NTRS)

    Miller, Geoffrey; Richwine, David M.; Hass, Neal E.

    1996-01-01

    Advanced video data-acquisition system (AVDAS) developed to satisfy variety of requirements for in-flight video documentation. Requirements range from providing images for visualization of airflows around fighter airplanes at high angles of attack to obtaining safety-of-flight documentation. F/A-18 AVDAS takes advantage of very capable systems like NITE Hawk forward-looking infrared (FLIR) pod and recent video developments like miniature charge-couple-device (CCD) color video cameras and other flight-qualified video hardware.

  8. Meta-tools for software development and knowledge acquisition

    NASA Technical Reports Server (NTRS)

    Eriksson, Henrik; Musen, Mark A.

    1992-01-01

    The effectiveness of tools that provide support for software development is highly dependent on the match between the tools and their task. Knowledge-acquisition (KA) tools constitute a class of development tools targeted at knowledge-based systems. Generally, KA tools that are custom-tailored for particular application domains are more effective than are general KA tools that cover a large class of domains. The high cost of custom-tailoring KA tools manually has encouraged researchers to develop meta-tools for KA tools. Current research issues in meta-tools for knowledge acquisition are the specification styles, or meta-views, for target KA tools used, and the relationships between the specification entered in the meta-tool and other specifications for the target program under development. We examine different types of meta-views and meta-tools. Our current project is to provide meta-tools that produce KA tools from multiple specification sources--for instance, from a task analysis of the target application.

  9. Panoramic dynamic data acquisition system based on unmanned helicopter

    NASA Astrophysics Data System (ADS)

    Yao, Yigang; Zhao, Shuguang; Lin, Zhaorong; Wen, Gaojin; Zhang, Qian; Zhang, Weiwei

    2012-10-01

    In recent years, the archaeological tourism has rapidly been developed all over the world, and it has become more and more popular. However, the scope of the human activities has been restricted by complicated geographical terrain, and the popularization of archaeological tourism has been hampered. For the purpose of solving the above problem, the archaeological tourism system of the panoramic dynamic data acquisition system based on unmanned helicopter is designed, and we got the image of the Chinese Ming Dynasty Great Wall realtime 360˚ panoramic dynamic monitor. The applying of this system will increase the scope of the archaeological tourism activities.

  10. VME-Macintosh data acquisition system with ECL readout

    NASA Astrophysics Data System (ADS)

    Anzalone, A.; Manno, C. M. Iacono; Ferrera, F.; Barbagallo, G.; Cali, C.; Yingmei, Gu.; Giustolist, F.

    1994-02-01

    A new data acquisition system has been developed at LNS to match the experimental request of handling hundreds of parameters and spectra with a input event frequency of a few kHz. Both the traditional CAMAC and a few faster ECL readout dataways are supported. To enhance the system flexibility three different kinds of CAMAC ADCs can be used (GAN'ELEC QDC1612F, FERA 43008, SILENA ADC4418/V). Two HSM8170 interfaces are adopted between the EXB-8200 tape unit is connected to the system for off-line processing data storage.

  11. A VME-Macintosh data acquisition system with ECL readout

    SciTech Connect

    Anzalone, A.; Manno, C.M.I.; Ferrera, F.; Barbagallo, G.; Cali, C. . Lab. Nazionali del Sud); Yingmei, G. . Inst. of Nuclear Research); Giustolisi, F. . Dipt. di Fisica)

    1994-02-01

    A new Data Acquisition System has been developed at LNS to match the experimental request of handling hundreds of parameters and spectra with an input event frequency of a few kHz. Both the traditional CAMAC and a new faster ECL readout dataways are supported. To enhance the system flexibility three different kinds of CAMAC ADCs can be used (GAN'ELEC QDC1612F, FERA 4300B, SILENA ADC4418/V.) Two HSM8170 interfaces are adopted between the ECLbus and the VMEbus as ECL-VME buffers. An EXB-8200 tape unit is connected to the system for off-line processing data storage.

  12. The Nuclotron internal target control and data acquisition system

    NASA Astrophysics Data System (ADS)

    Isupov, A. Yu.; Krasnov, V. A.; Ladygin, V. P.; Piyadin, S. M.; Reznikov, S. G.

    2013-01-01

    The new control system of the Nuclotron (JINR, Dubna) internal target is described in both hardware and software aspects. The CAMAC hardware is based on the use of the standard CAMAC modules developed and manufactured at JINR. The internal target control and data acquisition (IntTarg CDAQ) system software is implemented using the ngdp framework under the Unix-like operating system (OS) FreeBSD to allow easy network distribution of the online data collected from internal target and accompanying detectors, as well as the internal target remote control.

  13. The PAN-DA data acquisition system

    SciTech Connect

    Petravick, D.; Berg, D.; Berman, E.; Bernett, M.; Constanta-Fanourakis, P.; Dorries, T.; Haire, M.; Kaczar, K; MacKinnon, B.; Moore, C.; Nicinski, T.; Oleynik, G.; Pordes, R.; Sergey, G.; Votava, M.; White, V.

    1989-05-01

    The Online and Data Acquisition software groups at Fermi National Accelerator Laboratory have extended the VAXONLINE data acquisition package to include a VME based data path. The resulting environment, PAN-DA, provides a high throughput for logging, filtering, formatting and selecting events. 10 refs., 1 fig.

  14. A triggerless digital data acquisition system for nuclear decay experiments

    SciTech Connect

    Agramunt, J.; Tain, J. L.; Albiol, F.; Algora, A.; Estevez, E.; Giubrone, G.; Jordan, M. D.; Molina, F.; Rubio, B.; Valencia, E.

    2013-06-10

    In nuclear decay experiments an important goal of the Data Acquisition (DAQ) system is to allow the reconstruction of time correlations between signals registered in different detectors. Classically DAQ systems are based in a trigger that starts the event acquisition, and all data related with the event of that trigger are collected as one compact structure. New technologies and electronics developments offer new possibilities to nuclear experiments with the use of sampling ADC-s. This type of ADC-s is able to provide the pulse shape, height and a time stamp of the signal. This new feature (time stamp) allows new systems to run without an event trigger. Later, the event can be reconstructed using the time stamp information. In this work we present a new DAQ developed for {beta}-delayed neutron emission experiments. Due to the long moderation time of neutrons, we opted for a self-trigger DAQ based on commercial digitizers. With this DAQ a negligible acquisition dead time was achieved while keeping a maximum of event information and flexibility in time correlations.

  15. DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM

    SciTech Connect

    YENG,Y.GASSNER,D.HOFF,L.WITKOVER,R.

    2003-10-13

    The Spallation Neutron Source (SNS) beam loss monitor system uses VME based electronics to measure the radiation produced by lost beam. Beam loss signals from cylindrical argon-filled ion chambers and neutron detectors will be conditioned in analog front-end (AFE) circuitry. These signals will be digitized and further processed in a dedicated VME crate. Fast beam inhibit and low-level, long-term loss warnings will be generated to provide machine protection. The fast loss data will have a bandwidth of 35kHz. While the low level, long-term loss data will have much higher sensitivity. This is further complicated by the 3 decade range of intensity as the Ring accumulates beam. Therefore a bandwidth of 100kHz and dynamic range larger than 21 bits data acquisition system will be required for this purpose. Based on the evaluation of several commercial ADC modules in preliminary design phase, a 24 bits Sigma-Delta data acquisition VME bus card was chosen as the SNS BLM digitizer. An associated vxworks driver and EPICS device support module also have been developed at BNL. Simulating test results showed this system is fully qualified for both fast loss and low-level, long-term loss application. The first prototype including data acquisition hardware setup and EPICS software (running database and OPI clients) will be used in SNS Drift Tube Linac (DTL) system commissioning.

  16. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound data acquisition system. (a) Systems...

  17. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound data acquisition system. (a) Systems...

  18. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound data acquisition system. (a) Systems...

  19. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Sound data acquisition system. 205.54-2 Section 205.54-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound data acquisition system. (a) Systems...

  20. The new digital data acquisition system for Gammasphere

    NASA Astrophysics Data System (ADS)

    Carpenter, M. P.; Albers, M.; Anderson, J. T.; Ayangeakaa, A.; David, H. M.; Hoffman, C. R.; Janssens, R. V. F.; Lauritsen, T.; Madden, T.; Oberling, M.; Seweryniak, D.; Wilt, P.; Zhu, S.

    2015-10-01

    A new digital-based data acquisition system (DAQ) for Gammasphere has been developed. This system leverages the electronics designed for the GRETINA collaboration. At the center of this development are the GRETINA 10-channel digitizer modules which handle the Ge preamp signals at a 100MHz rate, and master trigger and router modules which allow triggers to be constructed from information obtained from the digitizer channels. The new DAQ increases event throughput significantly over the existing system while addressing multiple repair and maintenance issues. New hardware and firmware to integrate the DAQ with Gammasphere and its suite of ancillary detectors has been developed allowing for a seamless changeover from the analog DAQ to the new digital system. An overview of the system and illustrative results from several recent experiments will be presented. This material is based on work supported by the DOE, Office of Science, Office of Nuclear Physics under Contract No. DE-AC02-06CH11357.

  1. Acoustic imaging systems (for robotic object acquisition)

    NASA Astrophysics Data System (ADS)

    Richardson, J. M.; Martin, J. F.; Marsh, K. A.; Schoenwald, J. S.

    1985-03-01

    The long-term objective of the effort is to establish successful approaches for 3D acoustic imaging of dense solid objects in air to provide the information required for acquisition and manipulation of these objects by a robotic system. The objective of this first year's work was to achieve and demonstrate the determination of the external geometry (shape) of such objects with a fixed sparse array of sensors, without the aid of geometrical models or extensive training procedures. Conventional approaches for acoustic imaging fall into two basic categories. The first category is used exclusively for dense solid objects. It involves echo-ranging from a large number of sensor positions, achieved either through the use of a larger array of transducers or through extensive physical scanning of a small array. This approach determines the distance to specular reflection points from each sensor position; with suitable processing an image can be inferred. The second category uses the full acoustic waveforms to provide an image, but is strictly applicable only to weak inhomogeneities. The most familiar example is medical imaging of the soft tissue portions of the body where the range of acoustic impedance is relatively small.

  2. Software for Digital Acquisition System and Application to Environmental Monitoring

    NASA Technical Reports Server (NTRS)

    Copeland, G. E.

    1975-01-01

    Criteria for selection of a minicomputer for use as a core resident acquisition system were developed for the ODU Mobile Air Pollution Laboratory. A comprehensive data acquisition program named MONARCH was instituted in a DEC-8/E-8K 12-bit computer. Up to 32 analog voltage inputs are scanned sequentially, converted to BCD, and then to actual numbers. As many as 16 external devices (valves or any other two-state device) are controlled independently. MONARCH is written as a foreground-background program, controlled by an external clock which interrupts once per minute. Transducer voltages are averaged over user specified time intervals and, upon completion of any desired time sequence, outputted are: day, hour, minute, second; state of external valves; average value of each analogue voltage (E Format); as well as standard deviations of these values. Output is compatible with any serially addressed media.

  3. Multi-Channel Data Acquisition System for Nuclear Pulse Processing

    SciTech Connect

    Myjak, Mitchell J.; Ma, Ding; Robinson, Dirk J.; La Rue, George S.

    2009-11-13

    We have developed a compact, inexpensive electronics package that can digitize pulse-mode or current-mode data from 32 detector outputs in parallel. The electronics package consists of two circuit boards: a custom acquisition board and an off-the-shelf processing board. The acquisition board features a custom-designed integrated circuit that contains an array of charge-to-pulse-width converters. The processing board contains a field programmable gate array that digitizes the pulse widths, performs event discrimination, constructs energy histograms, and executes any user-defined software. Together, the two boards cost around $1000. The module can transfer data to a computer or operate entirely as a standalone system. The design achieves 0.20% nonlinearity and 0.18% FWHM precision at full scale. However, the overall performance could be improved with some modifications to the integrated circuit.

  4. A high-speed transputer-based data acquisition system

    NASA Astrophysics Data System (ADS)

    Loureiro, C. F. M.; Santos, J. M. G. B.; Simões, J. B.; Correia, C. M. B. A.; Zilker, M.

    1996-01-01

    A 250 MHz 8-bit transputer-based data acquisition VME bus module is described. This module has been designed as the acquisition node of a transputer-based real-time processing and data reduction system for the reflectometry diagnostic in the ASDEX Upgrade tokamak experiment. The architecture of the board is detailed, emphasizing the advantages of using recently delivered devices, like fast synchronous FIFOs, in a mixed ECL/TTL data acquisition architecture. It is shown that the implemented architecture leads naturally to the implementation of hardware triggers that allow the acquisition channels to operate as stand-alone modules in a self-triggered, self-timed, data acquisition mode. The advantages of using transputers as local control and processing units are discussed. The use of the board in the reflectometry diagnostic and the general processing goals of the system are presented together with data characterizing the performance of the acquisition channels.

  5. Monitoring and Acquisition Real-time System (MARS)

    NASA Technical Reports Server (NTRS)

    Holland, Corbin

    2013-01-01

    MARS is a graphical user interface (GUI) written in MATLAB and Java, allowing the user to configure and control the Scalable Parallel Architecture for Real-Time Acquisition and Analysis (SPARTAA) data acquisition system. SPARTAA not only acquires data, but also allows for complex algorithms to be applied to the acquired data in real time. The MARS client allows the user to set up and configure all settings regarding the data channels attached to the system, as well as have complete control over starting and stopping data acquisition. It provides a unique "Test" programming environment, allowing the user to create tests consisting of a series of alarms, each of which contains any number of data channels. Each alarm is configured with a particular algorithm, determining the type of processing that will be applied on each data channel and tested against a defined threshold. Tests can be uploaded to SPARTAA, thereby teaching it how to process the data. The uniqueness of MARS is in its capability to be adaptable easily to many test configurations. MARS sends and receives protocols via TCP/IP, which allows for quick integration into almost any test environment. The use of MATLAB and Java as the programming languages allows for developers to integrate the software across multiple operating platforms.

  6. Information management system breadboard data acquisition and control system.

    NASA Technical Reports Server (NTRS)

    Mallary, W. E.

    1972-01-01

    Description of a breadboard configuration of an advanced information management system based on requirements for high data rates and local and centralized computation for subsystems and experiments to be housed on a space station. The system is to contain a 10-megabit-per-second digital data bus, remote terminals with preprocessor capabilities, and a central multiprocessor. A concept definition is presented for the data acquisition and control system breadboard, and a detailed account is given of the operation of the bus control unit, the bus itself, and the remote acquisition and control unit. The data bus control unit is capable of operating under control of both its own test panel and the test processor. In either mode it is capable of both single- and multiple-message operation in that it can accept a block of data requests or update commands for transmission to the remote acquisition and control unit, which in turn is capable of three levels of data-handling complexity.

  7. Linking Parser Development to Acquisition of Syntactic Knowledge

    ERIC Educational Resources Information Center

    Omaki, Akira; Lidz, Jeffrey

    2015-01-01

    Traditionally, acquisition of syntactic knowledge and the development of sentence comprehension behaviors have been treated as separate disciplines. This article reviews a growing body of work on the development of incremental sentence comprehension mechanisms and discusses how a better understanding of the developing parser can shed light on two…

  8. MIRAGE: The data acquisition, analysis, and display system

    NASA Technical Reports Server (NTRS)

    Rosser, Robert S.; Rahman, Hasan H.

    1993-01-01

    Developed for the NASA Johnson Space Center and Life Sciences Directorate by GE Government Services, the Microcomputer Integrated Real-time Acquisition Ground Equipment (MIRAGE) system is a portable ground support system for Spacelab life sciences experiments. The MIRAGE system can acquire digital or analog data. Digital data may be NRZ-formatted telemetry packets of packets from a network interface. Analog signal are digitized and stored in experimental packet format. Data packets from any acquisition source are archived to a disk as they are received. Meta-parameters are generated from the data packet parameters by applying mathematical and logical operators. Parameters are displayed in text and graphical form or output to analog devices. Experiment data packets may be retransmitted through the network interface. Data stream definition, experiment parameter format, parameter displays, and other variables are configured using spreadsheet database. A database can be developed to support virtually any data packet format. The user interface provides menu- and icon-driven program control. The MIRAGE system can be integrated with other workstations to perform a variety of functions. The generic capabilities, adaptability and ease of use make the MIRAGE a cost-effective solution to many experimental data processing requirements.

  9. Improvements and modifications to the NASA microwave signature acquisition system

    NASA Technical Reports Server (NTRS)

    Jean, B. R.; Newton, R. W.; Warren, G. L.; Clark, B. V.; Zajicek, J. L.

    1978-01-01

    A user oriented description of the modified and upgraded Microwave Signature Acquisition System is provided. The present configuration of the sensor system and its operating characteristics are documented and a step-by-step operating procedure provides instruction for mounting the antenna truss assembly, readying the system for data acquisition, and for controlling the system during the data collection sequence. The resulting data products are also identified.

  10. The data acquisition system for the aCORN experiment

    NASA Astrophysics Data System (ADS)

    Dewey, Maynard; aCORN Collaboration

    2015-10-01

    The aCORN experiment measures the angular correlation between the electron and neutrino emitted in free neutron beta decay, via an electron-proton momentum correlation asymmetry. Doing so requires detecting neutron beta decay protons and electrons in coincidence. Protons are detected with a surface barrier detector while electrons are detected with a large scintillator whose light output is parceled into 19 photomultiplier tubes. Additionally there are eight scintillators that detect backscattered electrons so that these events may be removed from the data stream. This talk will discuss the novel data acquisition system (both hardware and software) that has been developed to handle the high throughput rates observed. NIST, DOE and NSF.

  11. Systolic time interval data acquisition system. Specialized cardiovascular studies

    NASA Technical Reports Server (NTRS)

    Baker, J. T.

    1976-01-01

    The development of a data acquisition system for noninvasive measurement of systolic time intervals is described. R-R interval from the ECG determines instantaneous heart rate prior to the beat to be measured. Total electromechanical systole (Q-S2) is measured from the onset of the ECG Q-wave to the onset of the second heart sound (S2). Ejection time (ET or LVET) is measured from the onset of carotid upstroke to the incisure. Pre-ejection period (PEP) is computed by subtracting ET from Q-S2. PEP/ET ratio is computed directly.

  12. 29. Perimeter acquisition radar building room #318, data processing system ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    29. Perimeter acquisition radar building room #318, data processing system area; data processor maintenance and operations center, showing data processing consoles - Stanley R. Mickelsen Safeguard Complex, Perimeter Acquisition Radar Building, Limited Access Area, between Limited Access Patrol Road & Service Road A, Nekoma, Cavalier County, ND

  13. A method for knowledge acquisition in diagnostic expert system.

    PubMed

    Li, Weishi; Li, Aiping; Li, Shudong

    2015-01-01

    Knowledge acquisition plays very important role in the diagnostic expert system. It usually takes a long period to acquire disease knowledge using the traditional methods. To solve this problem, this paper describes relations between rough set theory and rule-based description of diseases, which corresponds to the process of knowledge acquisition of diagnostic expert system. Then the exclusive rules, inclusive rules and disease images of disease are built based on the PDES diagnosis model, and the definition of probability rule is put forward. At last, the paper presents the rule-based automated induction reasoning method, including exhaustive search, post-processing procedure, estimation for statistic test and the bootstrap and resampling methods. We also introduce automated induction of the rule-based description, which is used in our diseases diagnostic expert system. The experimental results not only show that rough set theory gives a very suitable framework to represent processes of uncertain knowledge extraction, but also that this method induces diagnostic rules correctly. This method can act as the assistant tool for development of diagnosis expert system, and has an extensive application in intelligent information systems. PMID:26410329

  14. Modeling the target acquisition performance of active imaging systems.

    PubMed

    Espinola, Richard L; Jacobs, Eddie L; Halford, Carl E; Vollmerhausen, Richard; Tofsted, David H

    2007-04-01

    Recent development of active imaging system technology in the defense and security community have driven the need for a theoretical understanding of its operation and performance in military applications such as target acquisition. In this paper, the modeling of active imaging systems, developed at the U.S. Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate, is presented with particular emphasis on the impact of coherent effects such as speckle and atmospheric scintillation. Experimental results from human perception tests are in good agreement with the model results, validating the modeling of coherent effects as additional noise sources. Example trade studies on the design of a conceptual active imaging system to mitigate deleterious coherent effects are shown. PMID:19532626

  15. Modeling the target acquisition performance of active imaging systems

    NASA Astrophysics Data System (ADS)

    Espinola, Richard L.; Jacobs, Eddie L.; Halford, Carl E.; Vollmerhausen, Richard; Tofsted, David H.

    2007-04-01

    Recent development of active imaging system technology in the defense and security community have driven the need for a theoretical understanding of its operation and performance in military applications such as target acquisition. In this paper, the modeling of active imaging systems, developed at the U.S. Army RDECOM CERDEC Night Vision & Electronic Sensors Directorate, is presented with particular emphasis on the impact of coherent effects such as speckle and atmospheric scintillation. Experimental results from human perception tests are in good agreement with the model results, validating the modeling of coherent effects as additional noise sources. Example trade studies on the design of a conceptual active imaging system to mitigate deleterious coherent effects are shown.

  16. Language Sound Systems and Second Language Acquisition.

    ERIC Educational Resources Information Center

    Skaer, Peter M.

    A language typology based on common errors made in pronunciation of English by speakers of other languages is presented and discussed. The classification system was developed from the concept of interlanguage, the intermediate step between a language learner's native and target languages, and the notion that interference in learning a new language…

  17. Value-informed space systems design and acquisition

    NASA Astrophysics Data System (ADS)

    Brathwaite, Joy

    Investments in space systems are substantial, indivisible, and irreversible, characteristics that make them high-risk, especially when coupled with an uncertain demand environment. Traditional approaches to system design and acquisition, derived from a performance- or cost-centric mindset, incorporate little information about the spacecraft in relation to its environment and its value to its stakeholders. These traditional approaches, while appropriate in stable environments, are ill-suited for the current, distinctly uncertain, and rapidly changing technical and economic conditions; as such, they have to be revisited and adapted to the present context. This thesis proposes that in uncertain environments, decision-making with respect to space system design and acquisition should be value-based, or at a minimum value-informed. This research advances the value-centric paradigm by providing the theoretical basis, foundational frameworks, and supporting analytical tools for value assessment of priced and unpriced space systems. For priced systems, stochastic models of the market environment and financial models of stakeholder preferences are developed and integrated with a spacecraft-sizing tool to assess the system's net present value. The analytical framework is applied to a case study of a communications satellite, with market, financial, and technical data obtained from the satellite operator, Intelsat. The case study investigates the implications of the value-centric versus the cost-centric design and acquisition choices. Results identify the ways in which value-optimal spacecraft design choices are contingent on both technical and market conditions, and that larger spacecraft for example, which reap economies of scale benefits, as reflected by their decreasing cost-per-transponder, are not always the best (most valuable) choices. Market conditions and technical constraints for which convergence occurs between design choices under a cost-centric and a value

  18. Cognitive Development and the Acquisition of Language.

    ERIC Educational Resources Information Center

    Moore, Timothy E., Ed.

    This volume deals with various aspects of the relationship between linguistic ability and general cognitive development. It presents original, up-to-date research for child psychologists, linguists, psycholinguists, scholars, teachers, and students interested in this field and interprets the findings in the context of contemporary linguistic…

  19. Wireless Data-Acquisition System for Testing Rocket Engines

    NASA Technical Reports Server (NTRS)

    Lin, Chujen; Lonske, Ben; Hou, Yalin; Xu, Yingjiu; Gang, Mei

    2007-01-01

    A prototype wireless data-acquisition system has been developed as a potential replacement for a wired data-acquisition system heretofore used in testing rocket engines. The traditional use of wires to connect sensors, signal-conditioning circuits, and data acquisition circuitry is time-consuming and prone to error, especially when, as is often the case, many sensors are used in a test. The system includes one master and multiple slave nodes. The master node communicates with a computer via an Ethernet connection. The slave nodes are powered by rechargeable batteries and are packaged in weatherproof enclosures. The master unit and each of the slave units are equipped with a time-modulated ultra-wide-band (TMUWB) radio transceiver, which spreads its RF energy over several gigahertz by transmitting extremely low-power and super-narrow pulses. In this prototype system, each slave node can be connected to as many as six sensors: two sensors can be connected directly to analog-to-digital converters (ADCs) in the slave node and four sensors can be connected indirectly to the ADCs via signal conditioners. The maximum sampling rate for streaming data from any given sensor is about 5 kHz. The bandwidth of one channel of the TM-UWB radio communication system is sufficient to accommodate streaming of data from five slave nodes when they are fully loaded with data collected through all possible sensor connections. TM-UWB radios have a much higher spatial capacity than traditional sinusoidal wave-based radios. Hence, this TM-UWB wireless data-acquisition can be scaled to cover denser sensor setups for rocket engine test stands. Another advantage of TM-UWB radios is that it will not interfere with existing wireless transmission. The maximum radio-communication range between the master node and a slave node for this prototype system is about 50 ft (15 m) when the master and slave transceivers are equipped with small dipole antennas. The range can be increased by changing to

  20. An OS9-UNIX data acquisition system with ECL readout

    SciTech Connect

    Ziem, P.; Beschorner, C.; Bohne, W.; Drescher, B.; Friese, T.; Kiehne, T.; Kluge, C.

    1996-02-01

    A new data acquisition system has been developed at the Hahn-Meitner-Institut to handle almost 550 parameters of nuclear physics experiments. The system combines a UNIX host running a portable data buffer router and a VME front-end based on the OS9 real time operating system. Different kinds of pulse analyzers are located in several CAMAC crates which are controlled by the VME system via a VICbus connection. Data readout is performed by means of an ECL daisy chain. Besides controlling CAMAC the main purpose of the VME front-end is event data formatting and histogramming. Using TCP/IP services, the UNIX host receives formatted data packages for data storage and display. During a beam time at the antiproton accelerator LEAR/CERN, the PS208 experiment has accumulated about 100 Gbyte of event data.

  1. Data acquisition system for operational earth observation missions

    NASA Technical Reports Server (NTRS)

    Deerwester, J. M.; Alexander, D.; Arno, R. D.; Edsinger, L. E.; Norman, S. M.; Sinclair, K. F.; Tindle, E. L.; Wood, R. D.

    1972-01-01

    The data acquisition system capabilities expected to be available in the 1980 time period as part of operational Earth observation missions are identified. By data acquisition system is meant the sensor platform (spacecraft or aircraft), the sensors themselves and the communication system. Future capabilities and support requirements are projected for the following sensors: film camera, return beam vidicon, multispectral scanner, infrared scanner, infrared radiometer, microwave scanner, microwave radiometer, coherent side-looking radar, and scatterometer.

  2. Remote data acquisition system based on DataSocket technology

    NASA Astrophysics Data System (ADS)

    Li, Haitao; Yang, Le-Ping

    2003-09-01

    The paper discusses a design of a remote data acquisition system based on DataSocket technology, the main idea of this system is that using the abilities of high speed live data publishing and data sharing of DataSocket technology to transmit the control commands of DAQ cards and measurement data. This system resolves the problems of using RDA technology to realize remote data acquisition.

  3. Infant Language Development Is Related to the Acquisition of Walking

    ERIC Educational Resources Information Center

    Walle, Eric A.; Campos, Joseph J.

    2014-01-01

    The present investigation explored the question of whether walking onset is related to infant language development. Study 1 used a longitudinal design (N = 44) to assess infant locomotor and language development every 2 weeks from 10 to 13.5 months of age. The acquisition of walking was associated with a significant increase in both receptive and…

  4. The DOE/NASA wind turbine data acquisition system. Part 3: Unattended power performance monitor

    NASA Technical Reports Server (NTRS)

    Halleyy, A.; Heidkamp, D.; Neustadter, H.; Olson, R.

    1983-01-01

    Software documentation, operational procedures, and diagnostic instructions for development version of an unattended wind turbine performance monitoring system is provided. Designed to be used for off line intelligent data acquisition in conjunction with the central host computer.

  5. Data Acquisition And Control For Horizontal Weiss Balance With An Embedded System

    NASA Astrophysics Data System (ADS)

    Tunyagi, A. R.; Pop, V.

    2007-04-01

    A data acquisition and control system was developed for a Weiss balance. Using a high resolution LVDT position sensor and an embedded fuzzy-engine a real-time compensation and a long time stability was achieved.

  6. Data acquisition system for an advanced x-ray imaging crystal spectrometer using a segmented position-sensitive detector.

    PubMed

    Nam, U W; Lee, S G; Bak, J G; Moon, M K; Cheon, J K; Lee, C H

    2007-10-01

    A versatile time-to-digital converter based data acquisition system for a segmented position-sensitive detector has been developed. This data acquisition system was successfully demonstrated to a two-segment position-sensitive detector. The data acquisition system will be developed further to support multisegmented position-sensitive detector to improve the photon count rate capability of the advanced x-ray imaging crystal spectrometer system. PMID:17979416

  7. A data acquisition system for marine and ecological research.

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1971-01-01

    Description of a self-contained portable data acquisition system for use in marine and ecological research. The compact lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing. Currently undergoing component performance upgrading, the prototype system has been utilized in several environmental science investigations associated with air pollution investigations and weather modification and is currently being used for marine data acquisition.

  8. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    SciTech Connect

    Wheat, Jr., Robert Mitchell; Dalmas, Dale A.; Dale, Gregory E.

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

  9. 48 CFR 1.102 - Statement of guiding principles for the Federal Acquisition System.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Statement of guiding principles for the Federal Acquisition System. 1.102 Section 1.102 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION GENERAL FEDERAL ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 1.102 Statement of guiding principles...

  10. Computer Systems Acquisition and the Use of Letters of Credit.

    ERIC Educational Resources Information Center

    Wernick, Alan S.

    1988-01-01

    Describes letters of credit and their usefulness in financing computer systems acquisition. Relevant legal policies and the different types and applications of letters of credit are discussed. (1 reference) (MES)

  11. A novel time stamping technique for distributed data acquisition systems.

    PubMed

    Subramaniam, E T

    2012-12-01

    In this paper, we discuss the design and implementation of a synchronizing technique for data acquisition systems, which can effectively use the normal, standard local area network cables to provide a time stamp, with a range up to 32 days, resolution of 10 ns, and synchronization within ± 5 ns. This system may be used to synchronize data being collected by independent heterogeneous data acquisition modules, that acquire events independently. Such distributed systems are generally designed with a tree-like structure or independent self-triggered acquisition boxes. These leaf edges are connected through branches to the root node, via non-bus based inter-connecting links. The present system has been tested with a set of self-triggered digital signal processing based data acquisition engines, having a 100 MHz analog to digital converter front end. PMID:23277988

  12. Latency in Distributed Acquisition and Rendering for Telepresence Systems.

    PubMed

    Ohl, Stephan; Willert, Malte; Staadt, Oliver

    2015-12-01

    Telepresence systems use 3D techniques to create a more natural human-centered communication over long distances. This work concentrates on the analysis of latency in telepresence systems where acquisition and rendering are distributed. Keeping latency low is important to immerse users in the virtual environment. To better understand latency problems and to identify the source of such latency, we focus on the decomposition of system latency into sub-latencies. We contribute a model of latency and show how it can be used to estimate latencies in a complex telepresence dataflow network. To compare the estimates with real latencies in our prototype, we modify two common latency measurement methods. This presented methodology enables the developer to optimize the design, find implementation issues and gain deeper knowledge about specific sources of latency. PMID:26529463

  13. Data Acquisition System for Russian Arctic Magnetometer Network

    NASA Astrophysics Data System (ADS)

    Janzhura, A.; Troshichev, O. A.; Takahashi, K.

    2010-12-01

    Monitoring of magnetic activity in the auroral zone is very essential for space weather problem. The big part of northern auroral zone lies in the Russian sector of Arctica. The Russian auroral zone stations are located far from the proper infrastructure and communications, and getting the data from the stations is complicated and nontrivial task. To resolve this problem a new acquisition system for magnetometers was implemented and developed in last few years, with the magnetic data transmission in real time that is important for many forecasting purpose. The system, based on microprocessor modules, is very reliable in hush climatic conditions. The information from the magnetic sensors transmits to AARI data center by satellite communication system and is presented at AARI web pages. This equipment upgrading of Russian polar magnetometer network is supported by the international RapidMag program.

  14. Spent Fuel Test - Climax data acquisition system operations manual

    SciTech Connect

    Nyholm, R.A.

    1983-01-01

    The Spent Fuel Test-Climax (SFT-C) is a test of the retrievable, deep geologic storage of commercially generated, spent nuclear reactor fuel in granite rock. Eleven spent fuel assemblies, together with 6 electrical simulators and 20 guard heaters, are emplaced 420 m below the surface in the Climax granite at the US Department of Energy Nevada Test Site. On June 2, 1978, Lawrence Livermore National Laboratory (LLNL) secured funding for the SFT-C, and completed spent fuel emplacement May 28, 1980. The multi-year duration test is located in a remote area and is unattended much of the time. An extensive array of radiological safety and geotechnical instrumentation is deployed to monitor the test performance. A dual minicomputer-based data acquisition system (DAS) collects and processes data from more than 900 analog instruments. This report documents the software element of the LLNL developed SFT-C Data Acquisition System. It defines the operating system and hardware interface configurations, the special applications software and data structures, and support software.

  15. Designer crops: optimal root system architecture for nutrient acquisition.

    PubMed

    Kong, Xiangpei; Zhang, Maolin; De Smet, Ive; Ding, Zhaojun

    2014-12-01

    Plant root systems are highly plastic in response to environmental stimuli. Improved nutrient acquisition can increase fertilizer use efficiency and is critical for crop production. Recent analyses of field-grown crops highlighted the importance of root system architecture (RSA) in nutrient acquisition. This indicated that it is feasible in practice to exploit genotypes or mutations giving rise to optimal RSA for crop design in the future, especially with respect to plant breeding for infertile soils. PMID:25450041

  16. Quantitative knowledge acquisition for expert systems

    NASA Technical Reports Server (NTRS)

    Belkin, Brenda L.; Stengel, Robert F.

    1991-01-01

    A common problem in the design of expert systems is the definition of rules from data obtained in system operation or simulation. While it is relatively easy to collect data and to log the comments of human operators engaged in experiments, generalizing such information to a set of rules has not previously been a direct task. A statistical method is presented for generating rule bases from numerical data, motivated by an example based on aircraft navigation with multiple sensors. The specific objective is to design an expert system that selects a satisfactory suite of measurements from a dissimilar, redundant set, given an arbitrary navigation geometry and possible sensor failures. The systematic development is described of a Navigation Sensor Management (NSM) Expert System from Kalman Filter convariance data. The method invokes two statistical techniques: Analysis of Variance (ANOVA) and the ID3 Algorithm. The ANOVA technique indicates whether variations of problem parameters give statistically different covariance results, and the ID3 algorithms identifies the relationships between the problem parameters using probabilistic knowledge extracted from a simulation example set. Both are detailed.

  17. 15 CFR 921.21 - Initial acquisition and development awards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Initial acquisition and development awards. 921.21 Section 921.21 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT NATIONAL...

  18. Acquisition of Scientific Literature in Developing Countries. 1: Bangladesh.

    ERIC Educational Resources Information Center

    Saddique, Abu Bakr

    1989-01-01

    Summarizes the development of scientific and technological libraries and document centers in Bangladesh and describes the problems of acquiring scientific literature through purchase, gift, and exchange programs. The effectiveness of cooperative acquisition programs and international sources of document supply are examined, and plans for future…

  19. 15 CFR 921.31 - Supplemental acquisition and development awards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 3 2011-01-01 2011-01-01 false Supplemental acquisition and development awards. 921.31 Section 921.31 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT...

  20. 15 CFR 921.31 - Supplemental acquisition and development awards.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Supplemental acquisition and development awards. 921.31 Section 921.31 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE...

  1. Suprasegmental Phonology Development and Reading Acquisition: A Longitudinal Study

    ERIC Educational Resources Information Center

    Calet, Nuria; Gutiérrez-Palma, Nicolás; Simpson, Ian C.; González-Trujillo, M. Carmen; Defior, Sylvia

    2015-01-01

    Previous studies implicate suprasegmental phonology in reading acquisition. However, little is known about how suprasegmental sensitivity develops or how it contributes to reading. Here, 130 Spanish primary-school children participated in this 2-year longitudinal study. Nonlinguistic rhythm, lexical-stress sensitivity and metrical-stress…

  2. Reference Frames during the Acquisition and Development of Spatial Memories

    ERIC Educational Resources Information Center

    Kelly, Jonathan W.; McNamara, Timothy P.

    2010-01-01

    Four experiments investigated the role of reference frames during the acquisition and development of spatial knowledge, when learning occurs incrementally across views. In two experiments, participants learned overlapping spatial layouts. Layout 1 was first studied in isolation, and Layout 2 was later studied in the presence of Layout 1. The…

  3. Development of data acquisition and analysis software for multichannel detectors

    SciTech Connect

    Chung, Y.

    1988-06-01

    This report describes the development of data acquisition and analysis software for Apple Macintosh computers, capable of controlling two multichannel detectors. With the help of outstanding graphics capabilities, easy-to-use user interface, and several other built-in convenience features, this application has enhanced the productivity and the efficiency of data analysis. 2 refs., 6 figs.

  4. 15 CFR 921.31 - Supplemental acquisition and development awards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 15 Commerce and Foreign Trade 3 2014-01-01 2014-01-01 false Supplemental acquisition and development awards. 921.31 Section 921.31 Commerce and Foreign Trade Regulations Relating to Commerce and Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN AND COASTAL RESOURCE MANAGEMENT...

  5. The Wireless Data Acquisition System for the Vibration Table

    NASA Astrophysics Data System (ADS)

    Teng, Y. T.; Hu, X.

    2014-12-01

    The vibration table is a large-scaled tool used for inspecting the performance of seismometers. The output from a seismometer on the table can be directly monitored when the vibration table moves in certain pattern. Compared with other inspection methods, inspecting seismometers' performance indicators (frequency response, degree of linearity, sensitivity, lateral inhibition and dynamic range etc). using vibration tables is more intuitive. Therefore, the vibration tables are an essential testing part in developing new seismometers and seismometer quality control. Whereas, in practice, a cable is needed to connect the seismometer to the ground equipments for its signal outputs and power supply, that means adding a time-varying nonlinear spring between the vibration table and ground. The cable adds nonlinear feature to the table, distorts the table-board movement and bring extra errors to the inspecting work and affected the testing accuracy and precision. In face of this problem, we developed a wireless acquiring system for the vibration table. The system is consisted of a three-channel analog-to-digital conversion, an acquisition control part, local data storage, network interface, wireless router and power management, etc. The analog-to-digital conversion part uses a 24-digit high-precision converter, which has a programmable amplifier at the front end of its artificial circuit, with the function of matching outputs with different amplifier from the vibration table. The acquisition control part uses a 32 bit ARM processor, with low-power dissipation, minute extension and high performance. The application software platform is written in Linux to make the system convenient for multitasking work. Large volume local digital storage is achieved by a 32G SD card, which is used for saving real time acquired data. Data transmission is achieved by network interface and wireless router, which can simplify the application software by the supported TCP/IP protocol. Besides

  6. ACQUIRE: A data acquisition system for CAMAC on SUN workstations

    SciTech Connect

    Kouzes, R.T. ); Lowry, M.M. )

    1994-02-01

    The data acquisition software package ACQUIRE has been used for many years by the Princeton University Cyclotron Laboratory for nuclear physics research applications. This code has been ported to the SUN Sparc workstation and is fully functional, including block data transfers using an in crate Event Handler. A SCSI interface to CAMAC is utilized, and the device handling software has been developed in such a way that little modification was needed in the ACQUIRE code for the SUN implementation. The Higz X windows graphics package from CERN is used for data display. ACQUIRE will be used for test and development of CAMAC based systems within the Molecular Science Research Center at Pacific Northwest Laboratory.

  7. Effect of Vibration on Retention Characteristics of Screen Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Tegart, J. R.; Park, A. C.

    1977-01-01

    An analytical and experimental investigation of the effect of vibration on the retention characteristics of screen acquisition systems was performed. The functioning of surface tension devices using fine-mesh screens requires that the pressure differential acting on the screen be less than its pressure retention capability. When exceeded, screen breakdown will occur and gas-free expulsion of propellant will no longer be possible. An analytical approach to predicting the effect of vibration was developed. This approach considers the transmission of the vibration to the screens of the device and the coupling of the liquid and the screen in establishing the screen response. A method of evaluating the transient response of the gas/liquid interface within the screen was also developed.

  8. Computer-assisted knowledge acquisition for hypermedia systems

    NASA Technical Reports Server (NTRS)

    Steuck, Kurt

    1990-01-01

    The usage of procedural and declarative knowledge to set up the structure or 'web' of a hypermedia environment is described. An automated knowledge acquisition tool was developed that helps a knowledge engineer elicit and represent an expert's knowledge involved in performing procedural tasks. The tool represents both procedural and prerequisite, declarative knowledge that supports each activity performed by the expert. This knowledge is output and subsequently read by a hypertext scripting language to generate the link between blank, but labeled cards. Each step of the expert's activity and each piece of supporting declarative knowledge is set up as an empty node. An instructional developer can then enter detailed instructional material concerning each step and declarative knowledge into these empty nodes. Other research is also described that facilitates the translation of knowledge from one form into a form more readily useable by computerized systems.

  9. Multinode data acquisition and control system for the 4-element TACTIC telescope array

    NASA Astrophysics Data System (ADS)

    Yadav, K. K.; Chouhan, N.; Kaul, S. R.; Koul, R.

    2002-03-01

    An interrupt driven multinode data acquisition and control system has been developed for the 4-element gamma-ray telescope array, TACTIC. Computer networking technology and the CAMAC bus have been integrated to develop this icon-based, userfriendly failsafe system. The paper describes the salient features of the system.

  10. Data Acquisition System for Electric Vehicle's Driving Motor Test Bench Based on VC++

    NASA Astrophysics Data System (ADS)

    Qiang, Song; Chenguang, Lv

    In order to solve such problems as great labor intensity, high cost, low efficiency and accuracy during the performance experiment for driving motor system of electric vehicles, and realize data acquisition automatically and synchronously, a data acquisition system for driving motor test bench based on visual instruments is designed. This data acquisition system can be used to obtain the driving motor's parameters of currents and voltages at the same time. This system's hardware is based on electric vehicle's motor test bench in Beijing Institute of Technology, and combined with PXI2010 data acquisition card from ADLINK Company. Visual c++ software is adopted as development tool. In this paper, the design and realization of the hardware and software are presented. Experiment results show that this system improves the efficiency and quality of testing task with high utility. And experiment data can be obtained accurately.

  11. 77 FR 187 - Federal Acquisition Regulation; Transition to the System for Award Management (SAM)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-03

    ... pertaining to three procurement systems included in the Integrated Acquisition Environment--the Central... Certifications Application. These three Integrated Acquisition Environment systems and the Disaster Response.... Background The Integrated Acquisition Environment (IAE) is an electronic- Government initiative. The IAE...

  12. Review of digital fingerprint acquisition systems and wavelet compression

    NASA Astrophysics Data System (ADS)

    Hopper, Thomas

    2003-04-01

    Over the last decade many criminal justice agencies have replaced their fingerprint card based systems with electronic processing. We examine these new systems and find that image acquisition to support the identification application is consistently a challenge. Image capture and compression are widely dispersed and relatively new technologies within criminal justice information systems. Image quality assurance programs are just beginning to mature.

  13. Review of Supervisory Control and Data Acquisition (SCADA) Systems

    SciTech Connect

    Reva Nickelson; Briam Johnson; Ken Barnes

    2004-01-01

    A review using open source information was performed to obtain data related to Supervisory Control and Data Acquisition (SCADA) systems used to supervise and control domestic electric power generation, transmission, and distribution. This report provides the technical details for the types of systems used, system disposal, cyber and physical security measures, network connections, and a gap analysis of SCADA security holes.

  14. A design of camera simulator for photoelectric image acquisition system

    NASA Astrophysics Data System (ADS)

    Cai, Guanghui; Liu, Wen; Zhang, Xin

    2015-02-01

    In the process of developing the photoelectric image acquisition equipment, it needs to verify the function and performance. In order to make the photoelectric device recall the image data formerly in the process of debugging and testing, a design scheme of the camera simulator is presented. In this system, with FPGA as the control core, the image data is saved in NAND flash trough USB2.0 bus. Due to the access rate of the NAND, flash is too slow to meet the requirement of the sytsem, to fix the problem, the pipeline technique and the High-Band-Buses technique are applied in the design to improve the storage rate. It reads image data out from flash in the control logic of FPGA and output separately from three different interface of Camera Link, LVDS and PAL, which can provide image data for photoelectric image acquisition equipment's debugging and algorithm validation. However, because the standard of PAL image resolution is 720*576, the resolution is different between PAL image and input image, so the image can be output after the resolution conversion. The experimental results demonstrate that the camera simulator outputs three format image sequence correctly, which can be captured and displayed by frame gather. And the three-format image data can meet test requirements of the most equipment, shorten debugging time and improve the test efficiency.

  15. Evolutionary analysis of iron (Fe) acquisition system in Marchantia polymorpha.

    PubMed

    Lo, Jing-Chi; Tsednee, Munkhtsetseg; Lo, Ying-Chu; Yang, Shun-Chung; Hu, Jer-Ming; Ishizaki, Kimitsune; Kohchi, Takayuki; Lee, Der-Chuen; Yeh, Kuo-Chen

    2016-07-01

    To acquire appropriate iron (Fe), vascular plants have developed two unique strategies, the reduction-based strategy I of nongraminaceous plants for Fe(2+) and the chelation-based strategy II of graminaceous plants for Fe(3+) . However, the mechanism of Fe uptake in bryophytes, the earliest diverging branch of land plants and dominant in gametophyte generation is less clear. Fe isotope fractionation analysis demonstrated that the liverwort Marchantia polymorpha uses reduction-based Fe acquisition. Enhanced activities of ferric chelate reductase and proton ATPase were detected under Fe-deficient conditions. However, M. polymorpha did not show mugineic acid family phytosiderophores, the key components of strategy II, or the precursor nicotianamine. Five ZIP (ZRT/IRT-like protein) homologs were identified and speculated to be involved in Fe uptake in M. polymorpha. MpZIP3 knockdown conferred reduced growth under Fe-deficient conditions, and MpZIP3 overexpression increased Fe content under excess Fe. Thus, a nonvascular liverwort, M. polymorpha, uses strategy I for Fe acquisition. This system may have been acquired in the common ancestor of land plants and coopted from the gametophyte to sporophyte generation in the evolution of land plants. PMID:26948158

  16. Advanced Data Acquisition Systems with Self-Healing Circuitry

    NASA Technical Reports Server (NTRS)

    Larson, William E.; Ihlefeld, Curtis M.; Medelius, Pedro J.; Delgado, H. (Technical Monitor)

    2001-01-01

    Kennedy Space Center's Spaceport Engineering & Technology Directorate has developed a data acquisition system that will help drive down the cost of ground launch operations. This system automates both the physical measurement set-up function as well as configuration management documentation. The key element of the system is a self-configuring, self-calibrating, signal-conditioning amplifier that automatically adapts to any sensor to which it is connected. This paper will describe the core technology behind this device and the automated data system in which it has been integrated. The paper will also describe the revolutionary enhancements that are planned for this innovative measurement technology. All measurement electronics devices contain circuitry that, if it fails or degrades, requires the unit to be replaced, adding to the cost of operations. Kennedy Space Center is now developing analog circuits that will be able to detect their own failure and dynamically reconfigure their circuitry to restore themselves to normal operation. This technology will have wide ranging application in all electronic devices used in space and ground systems.

  17. Data acquisition system for KOMAC beam monitoring using EPICS middleware

    NASA Astrophysics Data System (ADS)

    Song, Young-Gi

    2015-10-01

    The beam diagnostics instrument used to measure the beam properties is one of the important devices for the 100-MeV proton linear accelerator of the KOrea Multi-purpose Accelerator Complex (KOMAC). A data acquisition system (DAQ) is required to collect the output beam signals conditioned in the analog front-end circuitry of a beam loss monitor (BLM) and a beam position monitor (BPM). The electrical beam signal must be digitized, and the sampling has to be synchronized to a global timing system that produces a pulse signal for the pulsed beam operation. The digitized data must be accessible by the experimental physics and industrial control system (EPICS)-based control system, which manages all accelerator control. An input output controller (IOC), which runs Linux on a central process unit (CPU) module with a peripheral component interconnect (PCI) express-based Analog-to-digital converter (ADC) card, has been adopted to satisfy the requirements. An associated Linux driver and EPICS device support module have also been developed. The IOC meets the requirements, and the development and maintenance of software for the IOC is very efficient. In this paper, the details of the DAQ system for the BLM and the BPM with the introduction of the KOMAC beam-diagnostics devices, along with the performance, are described.

  18. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring.

    PubMed

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-01-01

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro. PMID:26295394

  19. Use of Low-Cost Acquisition Systems with an Embedded Linux Device for Volcanic Monitoring

    PubMed Central

    Moure, David; Torres, Pedro; Casas, Benito; Toma, Daniel; Blanco, María José; Del Río, Joaquín; Manuel, Antoni

    2015-01-01

    This paper describes the development of a low-cost multiparameter acquisition system for volcanic monitoring that is applicable to gravimetry and geodesy, as well as to the visual monitoring of volcanic activity. The acquisition system was developed using a System on a Chip (SoC) Broadcom BCM2835 Linux operating system (based on DebianTM) that allows for the construction of a complete monitoring system offering multiple possibilities for storage, data-processing, configuration, and the real-time monitoring of volcanic activity. This multiparametric acquisition system was developed with a software environment, as well as with different hardware modules designed for each parameter to be monitored. The device presented here has been used and validated under different scenarios for monitoring ocean tides, ground deformation, and gravity, as well as for monitoring with images the island of Tenerife and ground deformation on the island of El Hierro. PMID:26295394

  20. A High Performance Virtualized Seismic Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Davis, G. A.; Eakins, J. A.; Reyes, J. C.; Franke, M.; Sánchez, R. F.; Cortes Muñoz, P.; Busby, R. W.; Vernon, F.; Barrientos, S. E.

    2014-12-01

    As part of a collaborative effort with the Incorporated Research Institutions for Seismology, a virtualized seismic data acquisition and processing system was recently installed at the Centro Sismológical Nacional (CSN) at the Universidad de Chile for use as part of their early warning system. Using lessons learned from the Earthscope Transportable Array project, the design of this system consists of dedicated acquisition, processing and data distribution nodes hosted on a high availability hypervisor cluster. Data is exchanged with the IRIS Data Management Center and the existing processing infrastructure at the CSN. The processing nodes are backed by 20 TB of hybrid Solid State Disk (SSD) and spinning disk storage with automatic tiering of data between the disks. As part of the installation, best practices for station metadata maintenance were discussed and applied to the existing IRIS sponsored stations, as well as over 30 new stations being added to the early warning network. Four virtual machines (VM) were configured with distinctive tasks. Two VMs are dedicated to data acquisition, one to the real-time data processing, and one as relay between data acquisition and processing systems with services for the existing earthquake revision and dissemination infrastructure. The first acquisition system connects directly to Basalt dataloggers and Q330 digitizers, managing them, and acquiring seismic data as well as state-of-health (SOH) information. As newly deployed stations become available (beyond the existing 30), this VM is configured to acquire data from them and incorporate the additonal data. The second acquisition system imports the legacy network of CSN and data streams provided by other data centers. The processing system is connected to the production and archive databases. The relay system merges all incoming data streams and obtains the processing results. Data and processing packets are available for subsequent review and dissemination by the CSN. Such

  1. The performance of a sequential acquisition system for PN codes

    NASA Astrophysics Data System (ADS)

    Kerr, R. W.; Arakaki, E. M.; Huang, M. Y.

    Direct sequence spread spectrum techniques are being applied in an increasing number of advanced communication systems where anti-jam (AJ), low probability of intercept (LPI), or code division multiple access (CDMA) capabilities are required. In all these systems, rapid acquisition of long PN code is a system necessity. Generally, acquisition of long PN codes is accomplished by correlation measurements of the incoming sequence with a locally generated code sequence. However, instead of utilizing fixed integration times, a sequential acquisition technique could also be used for active correlation, which results in greatly reduced acquisition times. TRW has designed and completed a limited production of 33 spread spectrum receivers for use with the NASA Tracking Data Relay Satellite System (TDRSS). The receivers provide multiple access and ranging capability while simultaneously decreasing the transmitted power flux density to meet CCIR restrictions. This paper presents the analysis, hardware description, and performance of the sequential code acquisition system implemented on these receivers. A unique noise calibration process, which holds the key to successful operation of these receivers, is described in detail.

  2. The UCR gamma ray telescope data acquisition system

    NASA Technical Reports Server (NTRS)

    O'Neill, T. J.; Sweeney, W. E.; Tumer, O. T.; Zych, A. D.; White, R. S.

    1988-01-01

    A description is given of an electronics system based on the DEC Falcon SBC-11/23+, which has been designed and built to support a balloon-borne double Compton gamma-ray telescope. The system provides support for commands, data acquisition, data routing and compression, and photomultiplier tube gain control. The software consists of a number of interrupt-driven routines of differing priorities to handle each system task. This includes two circular buffers for onboard processing and bit encoding before transmission of the information to the ground computer. Acquisition of gamma-ray events at rates above the 200-Hz telemetry constraint is easily achieved.

  3. Generic model for smart-sensor-based data acquisition system

    NASA Astrophysics Data System (ADS)

    Ehrlich, Jacques; Zerrouki, Amal; Galisson, Arnaud; Demassieux, Nicolas

    1996-05-01

    Smart sensor is a recent concept presenting numerous advantages such as versatility, strong electromagnetic immunity, reduction of the connectivity, high computation power, etc. In civil engineering smart sensor based systems are well suited due to the large amount of spatially distant transducers and the need of large computational power. However, such systems require long development time, especially in their software part, and beside the multitude of instrumentation problems encountered, the need of a generic model is strong. The aim of the model is the design of a software generator for distributed data acquisition system. The key of our system is in the description of an instrumentation plane under the form of a data dependence graph (DDG). The goal of the generator is to map and 'execute' that DDG on the physical architecture according to the number of transducers, their affectation to the smart sensors and a PC based system controller. In this paper, after an outline of the smart sensor concept, we describe the DDG based representation of the instrumentation plan. An example of bridge monitoring is then described. Finally, the smart sensor, the system controller and the network modelization are outlined and their ability to allow the DDG mapping with the help of local or remote variable is shown.

  4. Data acquisition and control system for high-performance large-area CCD systems

    NASA Astrophysics Data System (ADS)

    Afanasieva, I. V.

    2015-04-01

    Astronomical CCD systems based on second-generation DINACON controllers were developed at the SAO RAS Advanced Design Laboratory more than seven years ago and since then have been in constant operation at the 6-meter and Zeiss-1000 telescopes. Such systems use monolithic large-area CCDs. We describe the software developed for the control of a family of large-area CCD systems equipped with a DINACON-II controller. The software suite serves for acquisition, primary reduction, visualization, and storage of video data, and also for the control, setup, and diagnostics of the CCD system.

  5. Data acquisition system for the BESS-Polar experiment

    NASA Astrophysics Data System (ADS)

    Orito, Reiko

    The Balloon-borne experiment with a superconducting spectrometer on a long duration balloon flight in Antarctica (BESS-Polar) has been carried out to investigate elementary particle phenomena in the early universe through the measurement of cosmic-ray antiparticles[1]. To realize the long term observation over 20 days, the data acquisition system(DAQ) for the BESS-Polar spectrometer has been newly developed with a base of previous BESS-DAQ[2]. The BESS-Polar DAQ system consists of low-power front end electronics(FEE)[3], high speed processors, large capacity data storage, telemetry communicating system, monitors for the spectrometer, and the solar-panel power supply system. The data from the FEEs(TDCs, QDCs, FADCs) are converted to USB2.0 signal and sent to the dual core processor with a CompactPCI bus. The event is built(˜3k byte/event) and recorded to the data storage with an array of sixteen 1TB-HDDs. The data recording system is installed in the compact pressurized data vessel with a proper thermal treatment. The dead time of data acquisition was below 20% at 2.5kHz trigger rate during the flight. The total power consumption of the BESS- Polar spectrometer was 500W. The power lines from the solar panels to the spectrometer are controlled by the programmable TOSHIBA Neuron chips and the low-power PC104 system. The monitor data and the telemetry are also received by original modules on the PC104 system. This system was operated during the scientific run for 24.5 days over Antarctica and successfully recorded 4.6 billion cosmic-ray events during the solar minimum period in 2007-2008. All the DAQ system was well operated without any critical problem. In this presentation, the DAQ system for the BESS-Polar experiment and its performances will be reported. References: [1] A.Yamamoto et al., Nuclear Physics B, Vol.166, 2007, pp.62-67 [2] Y. Ajima et al., Nucl. Instr. and Methods , A 443, 2000, pp.71-100 [3] M.Sasaki et al., 29th ICRC, Pune (2005) 3, pp.421-424

  6. [Audio capture in the hybrid system of nursing training: contribution to the acquisition of knowledge for the development of professional skills].

    PubMed

    Hoyelle-Pierre, Stéphanie; Villemonteix, François

    2015-12-01

    This article deals with the results of a probing study in the framework of the education and technology master of research in educational science of the university of Cergy-Pontoise. This study focuses on the use of audio capture by first year nursing students in the development of their knowledge and therefore in the development of their professional skills. By using the model of the unified theory of acceptance and use of technology (UTAUT), the results of this study have helped to identify the levers (easy-to-use digital resources, computer skilled learners, multiplicity of computer equipment of the learners) and bridles (the relative gain when using this resource, the lack of human interaction, a resource which is time consuming) in the use of audio capture. A more extensive study could focus on these bridles in order to promote the use of audio capture by learners in the hybrid system of nursing training. PMID:26946809

  7. Knowledge-acquisition tools for medical knowledge-based systems.

    PubMed

    Lanzola, G; Quaglini, S; Stefanelli, M

    1995-03-01

    Knowledge-based systems (KBS) have been proposed to solve a large variety of medical problems. A strategic issue for KBS development and maintenance are the efforts required for both knowledge engineers and domain experts. The proposed solution is building efficient knowledge acquisition (KA) tools. This paper presents a set of KA tools we are developing within a European Project called GAMES II. They have been designed after the formulation of an epistemological model of medical reasoning. The main goal is that of developing a computational framework which allows knowledge engineers and domain experts to interact cooperatively in developing a medical KBS. To this aim, a set of reusable software components is highly recommended. Their design was facilitated by the development of a methodology for KBS construction. It views this process as comprising two activities: the tailoring of the epistemological model to the specific medical task to be executed and the subsequent translation of this model into a computational architecture so that the connections between computational structures and their knowledge level counterparts are maintained. The KA tools we developed are illustrated taking examples from the behavior of a KBS we are building for the management of children with acute myeloid leukemia. PMID:9082135

  8. S3DACS - SPACE SIMULATOR SYSTEM DATA ACQUISITION AND CONTROL

    NASA Technical Reports Server (NTRS)

    De, Freitas Bart F.

    1994-01-01

    The S3 Data Acquisition and Control System, S3DACS, was developed for the Environmental Test Laboratory and Space Simulator at NASA's Jet Propulsion Laboratory. The program is used for monitoring, controlling, and recording information acquired during tests and presenting this information in various formats for easy access by a large number of users. All testing is initiated by a setup procedure that defines what will be tested, limits to be checked, formulas to use, etc. Test results (e.g. temperature, resistance) are then automatically stored in a database for real time display and for future reference. Measurements obtained may be used in various computations defined for the test and selectively presented in tabular, graphical, or electronic representation. Reports may show current or historical events. The S3DACS network software is written in FoxPro/LAN 1.02 and 80386 Assembler for IBM PC and compatibles running MS-DOS 3.31 or higher. Machine requirements include: an 80386 33MHz machine with 10Mb RAM set up as a file server; an 80386 33MHz machine with 4Mb RAM connected to a FLUKE 2240B or 2280 data acquisition device; and an 80386 20MHz machine with 5Mb RAM used as a workstation. Also needed is a National Instruments General Purpose Interface Bus-compatible (GP-IB) Board to enable S3DACS to communicate with IEEE-488 control instruments. Software requirements include: Novell Netware 386 for network management; FoxPro/LAN 1.02 for database management; QEMM 386 version 5.0 for memory management; and DGE version 4, Saywhat, Viewlib, and DBSHOW for graphics and screen displays. The previous list of hardware is the minimum configuration which will allow installation of S3DACS. The addition of workstations and data acquisition devices can occur transparently. S3DACS is distributed on one 5.25 inch 1.2Mb MS-DOS format diskette. The extensive documentation includes a Quick Reference Guide, a Software User's Manual, a Computer Systems Operator's Manual, and a Software

  9. Internal Control, Auditing, and the Automated Acquisitions System.

    ERIC Educational Resources Information Center

    Hawks, Carol Pitts

    1990-01-01

    Discusses issues and procedures involved in auditing the automated acquisitions system at Ohio State University Libraries. The audit process is explained, internal controls within the system are identified, general control mechanisms such as limited electronic access are discussed, and application control mechanisms that relate to specific…

  10. The ATLAS Data Acquisition and High Level Trigger system

    NASA Astrophysics Data System (ADS)

    The ATLAS TDAQ Collaboration

    2016-06-01

    This paper describes the data acquisition and high level trigger system of the ATLAS experiment at the Large Hadron Collider at CERN, as deployed during Run 1. Data flow as well as control, configuration and monitoring aspects are addressed. An overview of the functionality of the system and of its performance is presented and design choices are discussed.

  11. College Bibliocentre Acquisition and Accounting System Description Manual.

    ERIC Educational Resources Information Center

    College Bibliocentre, Don Mills (Ontario).

    The Acquisition and Accounting System is a complex designed to perform all functions in the following areas: (1) ordering; (2) receipt, shipment and cancellation; (3) accounts payable, (4) invoicing, (5) order status, (6) inventory, (7) college budgeting and (8) management information reports. Some of the benefits that accrue from the system are:…

  12. Migrating Legacy Systems in the Global Merger & Acquisition Environment

    ERIC Educational Resources Information Center

    Katerattanakul, Pairin; Kam, Hwee-Joo; Lee, James J.; Hong, Soongoo

    2009-01-01

    The MetaFrame system migration project at WorldPharma, while driven by merger and acquisition, had faced complexities caused by both technical challenges and organizational issues in the climate of uncertainties. However, WorldPharma still insisted on instigating this post-merger system migration project. This project served to (1) consolidate the…

  13. 15 CFR 921.31 - Supplemental acquisition and development awards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN... the environment. Acquisition awards for the acquisition of lands or waters, or interests therein,...

  14. 15 CFR 921.31 - Supplemental acquisition and development awards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Foreign Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN... the environment. Acquisition awards for the acquisition of lands or waters, or interests therein,...

  15. A flexible computerized system for environmental data acquisition and transmission

    NASA Astrophysics Data System (ADS)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  16. High frequency data acquisition system for space shuttle main engine testing

    NASA Technical Reports Server (NTRS)

    Lewallen, Pat

    1987-01-01

    The high frequency data acquisition system developed for the Space Shuttle Main Engine (SSME) single engine test facility at the National Space Technology Laboratories is discussed. The real time system will provide engineering data for a complete set of SSME instrumentation (approx. 100 measurements) within 4 hours following engine cutoff, a decrease of over 48 hours from the previous analog tape based system.

  17. Waste retrieval sluicing system data acquisition system acceptance test report

    SciTech Connect

    Bevins, R.R.

    1998-07-31

    This document describes the test procedure for the Project W-320 Tank C-106 Sluicing Data Acquisition System (W-320 DAS). The Software Test portion will test items identified in the WRSS DAS System Description (SD), HNF-2115. Traceability to HNF-2115 will be via a reference that follows in parenthesis, after the test section title. The Field Test portion will test sensor operability, analog to digital conversion, and alarm setpoints for field instrumentation. The W-320 DAS supplies data to assist thermal modeling of tanks 241-C-106 and 241-AY-102. It is designed to be a central repository for information from sources that would otherwise have to be read, recorded, and integrated manually. Thus, completion of the DAS requires communication with several different data collection devices and output to a usable PC data formats. This test procedure will demonstrate that the DAS functions as required by the project requirements stated in Section 3 of the W-320 DAS System Description, HNF-2115.

  18. An Overview of Advanced Data Acquisition System (ADAS)

    NASA Technical Reports Server (NTRS)

    Mata, Carlos T.; Steinrock, T. (Technical Monitor)

    2001-01-01

    The paper discusses the following: 1. Historical background. 2. What is ADAS? 3. R and D status. 4. Reliability/cost examples (1, 2, and 3). 5. What's new? 6. Technical advantages. 7. NASA relevance. 8. NASA plans/options. 9. Remaining R and D. 10. Applications. 11. Product benefits. 11. Commercial advantages. 12. intellectual property. Aerospace industry requires highly reliable data acquisition systems. Traditional Acquisition systems employ end-to-end hardware and software redundancy. Typically, redundancy adds weight, cost, power consumption, and complexity.

  19. Automatic Speech Acquisition and Recognition for Spacesuit Audio Systems

    NASA Technical Reports Server (NTRS)

    Ye, Sherry

    2015-01-01

    NASA has a widely recognized but unmet need for novel human-machine interface technologies that can facilitate communication during astronaut extravehicular activities (EVAs), when loud noises and strong reverberations inside spacesuits make communication challenging. WeVoice, Inc., has developed a multichannel signal-processing method for speech acquisition in noisy and reverberant environments that enables automatic speech recognition (ASR) technology inside spacesuits. The technology reduces noise by exploiting differences between the statistical nature of signals (i.e., speech) and noise that exists in the spatial and temporal domains. As a result, ASR accuracy can be improved to the level at which crewmembers will find the speech interface useful. System components and features include beam forming/multichannel noise reduction, single-channel noise reduction, speech feature extraction, feature transformation and normalization, feature compression, and ASR decoding. Arithmetic complexity models were developed and will help designers of real-time ASR systems select proper tasks when confronted with constraints in computational resources. In Phase I of the project, WeVoice validated the technology. The company further refined the technology in Phase II and developed a prototype for testing and use by suited astronauts.

  20. LBL Magnetic-Measurements Data-Acquisition System

    SciTech Connect

    Green, M.I.; Nelson, D.H.

    1983-03-01

    The LBL Magnetic Measurements Engineering (MME) Group has developed a Real-Time Data Acquisition System (DAS) for magnetic measurements. The design objective was for a system that was versatile, portable, modular, expandable, quickly and easily reconfigurable both in hardware and software, and inexpensive. All objectives except the last were attained. An LSI 11/23 microcomputer is interfaced to a clock-calendar, printer, CRT control terminal, plotter with hard copy, floppy and hard disks, GPIB, and CAMAC buses. Off-the-shelf hardware and software have been used where possible. Operational capabilities include: (1) measurement of high permeability materials; (2) harmonic error analysis of (a) superconducting dipoles and (b) rare earth cobalt (REC) and conventional quadrupole magnets; and (3) 0.1% accuracy x-y mapping with Hall probes. Results are typically presented in both tabular and graphical form during measurements. Only minutes are required to switch from one measurement capability to another. Brief descriptions of the DAS capabilities, some of the special instrumentation developed to implement these capabilities, and planned developments are given below.

  1. A role for the developing lexicon in phonetic category acquisition

    PubMed Central

    Feldman, Naomi H.; Griffiths, Thomas L.; Goldwater, Sharon; Morgan, James L.

    2013-01-01

    Infants segment words from fluent speech during the same period when they are learning phonetic categories, yet accounts of phonetic category acquisition typically ignore information about the words in which sounds appear. We use a Bayesian model to illustrate how feedback from segmented words might constrain phonetic category learning by providing information about which sounds occur together in words. Simulations demonstrate that word-level information can successfully disambiguate overlapping English vowel categories. Learning patterns in the model are shown to parallel human behavior from artificial language learning tasks. These findings point to a central role for the developing lexicon in phonetic category acquisition and provide a framework for incorporating top-down constraints into models of category learning. PMID:24219848

  2. Rotary Percussive Sample Acquisition Tool (SAT): Hardware Development and Testing

    NASA Technical Reports Server (NTRS)

    Klein, Kerry; Badescu, Mircea; Haddad, Nicolas; Shiraishi, Lori; Walkemeyer, Phillip

    2012-01-01

    In support of a potential Mars Sample Return (MSR) mission an Integrated Mars Sample Acquisition and Handling (IMSAH) architecture has been proposed to provide a means for Rover-based end-to-end sample capture and caching. A key enabling feature of the architecture is the use of a low mass sample Acquisition Tool (SAT) that is capable of drilling and capturing rock cores directly within a sample tube in order to maintain sample integrity and prevent contamination across the sample chain. As such, this paper will describe the development and testing of a low mass rotary percussive SAT that has been shown to provide a means for core generation, fracture, and capture.

  3. Efficient Lossy Compression for Compressive Sensing Acquisition of Images in Compressive Sensing Imaging Systems

    PubMed Central

    Li, Xiangwei; Lan, Xuguang; Yang, Meng; Xue, Jianru; Zheng, Nanning

    2014-01-01

    Compressive Sensing Imaging (CSI) is a new framework for image acquisition, which enables the simultaneous acquisition and compression of a scene. Since the characteristics of Compressive Sensing (CS) acquisition are very different from traditional image acquisition, the general image compression solution may not work well. In this paper, we propose an efficient lossy compression solution for CS acquisition of images by considering the distinctive features of the CSI. First, we design an adaptive compressive sensing acquisition method for images according to the sampling rate, which could achieve better CS reconstruction quality for the acquired image. Second, we develop a universal quantization for the obtained CS measurements from CS acquisition without knowing any a priori information about the captured image. Finally, we apply these two methods in the CSI system for efficient lossy compression of CS acquisition. Simulation results demonstrate that the proposed solution improves the rate-distortion performance by 0.4∼2 dB comparing with current state-of-the-art, while maintaining a low computational complexity. PMID:25490597

  4. Experimental acquisition system for impedance tomography with active electrode approach.

    PubMed

    Rigaud, B; Shi, Y; Chauveau, N; Morucci, J P

    1993-11-01

    An experimental system for impedance tomography has been constructed. The acquisition system uses 16 multifunctional active electrodes, each including a current source and a voltage buffer. Images of active and reactive parts of different target impedances in a phantom filled with liquid have been obtained. The system performance has been compared with those of other systems using either a mesh phantom or rods as point sources used for the determination of the modulation transfer function. PMID:8145585

  5. New Iron Acquisition System in Bacteroidetes

    PubMed Central

    Manfredi, Pablo; Lauber, Frédéric; Renzi, Francesco; Hack, Katrin; Hess, Estelle

    2014-01-01

    Capnocytophaga canimorsus, a dog mouth commensal and a member of the Bacteroidetes phylum, causes rare but often fatal septicemia in humans that have been in contact with a dog. Here, we show that C. canimorsus strains isolated from human infections grow readily in heat-inactivated human serum and that this property depends on a typical polysaccharide utilization locus (PUL), namely, PUL3 in strain Cc5. PUL are a hallmark of Bacteroidetes, and they encode various products, including surface protein complexes that capture and process polysaccharides or glycoproteins. The archetype system is the Bacteroides thetaiotaomicron Sus system, devoted to starch utilization. Unexpectedly, PUL3 conferred the capacity to acquire iron from serotransferrin (STF), and this capacity required each of the seven encoded proteins, indicating that a whole Sus-like machinery is acting as an iron capture system (ICS), a new and unexpected function for Sus-like machinery. No siderophore could be detected in the culture supernatant of C. canimorsus, suggesting that the Sus-like machinery captures iron directly from transferrin, but this could not be formally demonstrated. The seven genes of the ICS were found in the genomes of several opportunistic pathogens from the Capnocytophaga and Prevotella genera, in different isolates of the severe poultry pathogen Riemerella anatipestifer, and in strains of Bacteroides fragilis and Odoribacter splanchnicus isolated from human infections. Thus, this study describes a new type of ICS that evolved in Bacteroidetes from a polysaccharide utilization system and most likely represents an important virulence factor in this group. PMID:25368114

  6. New iron acquisition system in Bacteroidetes.

    PubMed

    Manfredi, Pablo; Lauber, Frédéric; Renzi, Francesco; Hack, Katrin; Hess, Estelle; Cornelis, Guy R

    2015-01-01

    Capnocytophaga canimorsus, a dog mouth commensal and a member of the Bacteroidetes phylum, causes rare but often fatal septicemia in humans that have been in contact with a dog. Here, we show that C. canimorsus strains isolated from human infections grow readily in heat-inactivated human serum and that this property depends on a typical polysaccharide utilization locus (PUL), namely, PUL3 in strain Cc5. PUL are a hallmark of Bacteroidetes, and they encode various products, including surface protein complexes that capture and process polysaccharides or glycoproteins. The archetype system is the Bacteroides thetaiotaomicron Sus system, devoted to starch utilization. Unexpectedly, PUL3 conferred the capacity to acquire iron from serotransferrin (STF), and this capacity required each of the seven encoded proteins, indicating that a whole Sus-like machinery is acting as an iron capture system (ICS), a new and unexpected function for Sus-like machinery. No siderophore could be detected in the culture supernatant of C. canimorsus, suggesting that the Sus-like machinery captures iron directly from transferrin, but this could not be formally demonstrated. The seven genes of the ICS were found in the genomes of several opportunistic pathogens from the Capnocytophaga and Prevotella genera, in different isolates of the severe poultry pathogen Riemerella anatipestifer, and in strains of Bacteroides fragilis and Odoribacter splanchnicus isolated from human infections. Thus, this study describes a new type of ICS that evolved in Bacteroidetes from a polysaccharide utilization system and most likely represents an important virulence factor in this group. PMID:25368114

  7. RECENT DEVELOPMENTS IN ALTERNATIVES TO CAMAC FOR DATA ACQUISITION AT DIII-D

    SciTech Connect

    KELLMAN,D.H; CAMPBELL,G.L; FERRON,J.R; PIGLOWSKI,D.A; AUSTIN,M.E; MCKEE,G.R

    2003-10-01

    OAK-B135 For over twenty years, data acquisition hardware at DIII-D has been based on the CAMAC platform. These rugged and reliable systems, however, are gradually becoming obsolete due to end-of-life issues, ever-decreasing industry support of older hardware, and the availability of modern alternative hardware with superior performance. Efforts are underway at DIII-D to adopt new data acquisition solutions which exploit modern technologies and surpass the limitations of the CAMAC standard. These efforts have involved the procurement and development of data acquisition systems based on the PCI and Compact-PCI platform standards. These systems are comprised of rack-mount computers containing data acquisition boards (digitizers), Ethernet connectivity, and the drivers and software necessary for control. Each digitizer contains analog-to-digital converters, control circuitry, firmware and memory to collect, store, and transfer waveform data acquired using internal or external triggers and clocks. Software has been developed which allows DIII-D computers to program the operational parameters of the digitizers, as well as to upload acquired data into the DIII-D acquisition database. All communication between host computers and the new acquisition systems occurs via standard Ethernet connections, a vast improvement over the slower, serial loop highways used for control and data transfer with CAMAC systems. In addition, the capabilities available in modern integrated and printed circuit manufacture result in digitizers with high channel count and memory density. Cost savings are also realized by utilizing a platform based on standards of the personal computer industry. Details of the new systems at DIII-D are presented, along with initial experience with their use, and plans for future expansion and improvement.

  8. An Economical Astronomical Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Tucker, R. A.

    2003-05-01

    The MOTESS (Moving Object and Transient Event Search System) instrument has been in operation since April of 2001. This system consists of three tempera- ture-compensated, 14-inch aperture, f/5 Newtonian telescopes. Each telescope is equipped with a thinned, back-illuminated 1024x1024 CCD camera at the focus. Images are acquired using the scan-mode method of operation. Approxi- mately 12 square degrees per hour are recorded by each telescope revealing stars as faint as about magnitude 20.5. During the past two years of opera- tion, this facility has demonstrated its capability for asteroid observations by being the world's ninth most productive asteroid astrometry station. Ef- forts are now being made to photometrically analyze the accumulated imagery data to search for variable stars, extragalactic supernovae, and extrasolar planets. This instrument may be an excellent example of how abundant astro- nomical data may be reliably acquired at a modest cost.

  9. Beacon data acquisition and display system

    DOEpatents

    Skogmo, D.G.; Black, B.D.

    1991-12-17

    A system for transmitting aircraft beacon information received by a secondary surveillance radar through telephone lines to a remote display includes a digitizer connected to the radar for preparing a serial file of data records containing position and identification information of the beacons detected by each sweep of the radar. This information is transmitted through the telephone lines to a remote computer where it is displayed. 6 figures.

  10. Beacon data acquisition and display system

    DOEpatents

    Skogmo, David G.; Black, Billy D.

    1991-01-01

    A system for transmitting aircraft beacon information received by a secondary surveillance radar through telephone lines to a remote display includes a digitizer connected to the radar for preparing a serial file of data records containing position and identification information of the beacons detected by each sweep of the radar. This information is transmitted through the telephone lines to a remote computer where it is displayed.

  11. The upgraded HADES trigger and data acquisition system

    NASA Astrophysics Data System (ADS)

    Michel, J.; Böhmer, M.; Kajetanowicz, M.; Korcyl, G.; Maier, L.; Palka, M.; Stroth, J.; Tarantola, A.; Traxler, M.; Ugur, C.; Yurevich, S.

    2011-12-01

    The HADES experiment is a High Acceptance Di-Electron Spectrometer located at GSI in Darmstadt, Germany. Recently, its trigger and data acquisition system was upgraded. The main goal was to substantially increase the event rate capability by a factor of up to 20 to reach 100 kHz in light and 20 kHz in heavy ion reaction systems. The total data rate written to storage is about 400 MByte/s in peak. In this context, the complete read-out system was exchanged to FPGA-based platforms using optical communication. For data transport a general-purpose real-time network protocol was developed to meet the strong requirements of the system. In particular, trigger information has to reach all front-end modules with latencies of less than 5 μs through up to 10 intermediate hubs in a star-like network setup. Monitoring and slow control features as well as readout and trigger distribution were joined in a single network protocol made up by three virtual channels with inherent arbitration by priority and a typical switching time of 100 ns. The full DAQ system includes about 550 FPGAs distributed over the complete detector system. For control and monitoring a virtual address space spanning the whole network is provided. Data are merged by the network hubs into data streams and passed on to a server farm using an Ethernet infrastructure. Due to the electromagnetic noise environment, several transmission error detection and correction features were included. In collaboration with groups from experiments of the FAIR accelerator complex, further developments based on the versatile hardware and communication protocol are being pursued.

  12. 48 CFR 3001.102 - Statement of Guiding Principles for the Federal Acquisition System.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Statement of Guiding Principles for the Federal Acquisition System. 3001.102 Section 3001.102 Federal Acquisition Regulations... ACQUISITION REGULATIONS SYSTEM Purpose, Authority, Issuance 3001.102 Statement of Guiding Principles for...

  13. 48 CFR 3046.790 - Use of warranties in major systems acquisitions by the USCG (USCG).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 7 2010-10-01 2010-10-01 false Use of warranties in major systems acquisitions by the USCG (USCG). 3046.790 Section 3046.790 Federal Acquisition Regulations System DEPARTMENT OF HOMELAND SECURITY, HOMELAND SECURITY ACQUISITION REGULATION (HSAR) CONTRACT MANAGEMENT...

  14. The NA62 spectrometer acquisition system

    NASA Astrophysics Data System (ADS)

    Azorskiy, N.; Ceccucci, A.; Bendotti, J.; Danielsson, H.; Degrange, J.; Dixon, N.; Elsha, V.; Enik, T.; Glonti, L.; Gusakov, Y.; Kakurin, S.; Kekelidze, V.; Kislov, E.; Kolesnikov, A.; Koval, M.; Lichard, P.; Madigozhin, D.; Morant, J.; Movchan, S.; Perez Gomez, F.; Palladino, V.; Polenkevich, I.; Potrebenikov, Y.; Ruggiero, G.; Samsonov, V.; Shkarovskiy, S.; Sotnikov, A.

    2016-02-01

    The NA62 low mass spectrometer consists of 7000 straw tubes operating in vacuum. The front-end electronics is directly mounted on the detector and connected by a flexible PCB. The front-end board provides the amplification, shaping, discrimination and time measurements of the analogue signals from 16 channels. After digitisation the data is sent to a VME 9U read-out board. The data, once matched with the trigger, is sent to the next step and used by the trigger level 1 algorithm. The front-end and read-out systems of the detector will be presented along with the first results of the detector performances.

  15. Modular Wireless Data-Acquisition and Control System

    NASA Technical Reports Server (NTRS)

    Perotti, Jose; Lucena, Angel; Medelius, Pedro; Mata, Carlos; Eckhoff, Anthony; Blalock, Norman

    2004-01-01

    A modular wireless data-acquisition and control system, now in operation at Kennedy Space Center, offers high performance at relatively low cost. The system includes a central station and a finite number of remote stations that communicate with each other through low-power radio frequency (RF) links. Designed to satisfy stringent requirements for reliability, integrity of data, and low power consumption, this system could be reproduced and adapted to use in a broad range of settings.

  16. VME multiprocessor system for data acquisition at OSIRIS

    SciTech Connect

    Ziem, P.; Kiehne, T.; Beschorner, C.; Drescher, B.; Zahn, J.

    1987-08-01

    A VME multiprocessor system for data acquisition and data display utilizing several MC68XXX based CPUs and VMEbuses is described. The design of the VME system was stimulated by the data handling requirements of experiments using the anti-Compton spectrometer OSIRIS, i.e. data storage on optical disks and on-line accumulation of large 2-dimensional histograms (4096 x 4096 channels). Due to the general approach the VME system is easily applicable for other nuclear physics experiments.

  17. 40 CFR 205.54-2 - Sound data acquisition system.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Sound data acquisition system. 205.54... ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.54-2 Sound... established as equivalent to a Type I—ANSI S1.4-1971 sound level meter for use in determining compliance...

  18. Automated data acquisition and reduction system for torsional braid analyzer

    NASA Technical Reports Server (NTRS)

    Carl, G. L.; Inge, A. T.; Johnston, N. J.; Dalal, S. K.

    1975-01-01

    Automated Data Acquisition and Reduction System (ADAR) evaluates damping coefficient and relative rigidity by storing four successive peaks of waveform and time period between two successive peaks. Damping coefficient and relative rigidity are then calculated and plotted against temperature or time in real time.

  19. A status report on the SLD data acquisition system

    SciTech Connect

    Not Available

    1988-11-01

    The basic design of the SLD data acquisition system and its present status are reviewed. Aspects of the design that take particular advantage of the relatively low e/sup +/e/sup /minus// cross section and the low beam crossing rate of a linear collider are explained. 14 refs., 8 figs.

  20. Data acquisition system used in radiation induced electrical degradation experiments

    SciTech Connect

    White, D.P.

    1995-04-01

    Radiation induced electrical degradation (RIED) of ceramic materials has recently been reported and is the topic of much research at the present time. The object of this report is to describe the data acquisition system for an experiment designed to study RIED at the High Flux Beam Reactor (HFBR) at Brookhaven National Laboratory.

  1. Auto-Routable, Configurable, Daisy Chainable Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Shuler, Robert L. (Inventor)

    2005-01-01

    A method and apparatus for an acquisition system includes a plurality of sensor input signal lines. At least one of the plurality of sensor input signal lines operatively connects to at least one of a plurality of amplifier circuits. At least one of the plurality of amplifier circuits operatively connects to at least one of a plurality of filter circuits.

  2. Bell Laboratories Book Acquisition, Accounting and Cataloging System (BELLTIP).

    ERIC Educational Resources Information Center

    Sipfle, William K.

    BELLTIP is an on-line library processing system concerned with book acquisitions, cataloging, and financial accounting for a newwork of 26 technical libraries. At its center is an interactively updated and queried set of files concerned with all items currently in process. Principal products include all purchase orders, claims, and cancellations;…

  3. Experiences with the application of LAN emulation in a data acquisition system

    SciTech Connect

    Laat, C.T.A.M. de; Kuijer, P.G.; Olthuis, H.P.; Giesing, V.J.; Venema, J.

    1997-08-01

    Distributed data-acquisition and run-control system was developed for controlling and monitoring all experiments in the Nuclear Physics Department at Utrecht University, The Netherlands. The system consists of two almost independent parts: the readout hardware and real-time software system UDAQ, and the monitoring and control software Utrecht Measurement Analysis and Control utility (UMAC). The authors applied for the first time the ATM technology and the LAN Emulation protocol in an existing data acquisition system. The distributed data acquisition system, based on standard host computers connected via TCP/IP over ethernet to processors in VME crates was upgraded using ethernet to ATM bridges and ATM switches. The maximum data rates in the new situation are a factor of five higher than in the previous architecture because the VME processors have individual bottleneck-free network connections to the host computer. This system scales with the available ATM network bandwidth and host computer CPU power.

  4. The Data Acquisition System for a Kinetic Inductance Detector

    NASA Astrophysics Data System (ADS)

    Branchini, P.; Budano, A.; Capasso, L.; Marchetti, D.

    2015-12-01

    The Data Acquisition System (DAQ) and the Front-End electronics for an array of Kinetic Inductance Detectors (KIDs) are described. KIDs are superconductive detectors, in which electrons are organized in Cooper pairs. Any incident radiation could break a pair generating a couple of quasi-particles that increase the inductance of the detector. The DAQ system we developed is a hardware/software co-design, based on state machines and on a microprocessor embedded into an FPGA. A commercial DAC/ADC board is used to interface the FPGA to the array of KIDs. The DAQ system generates a Stimulus signal suitable for an array of up to 128 KIDs. Such signal is up-mixed with a 3 GHz carrier wave and it then excites the KIDs array. The read-out signal from the detector is down-mixed with respect to the 3 GHz sine wave and recovered Stimulus is read back by the ADC device. The microprocessor stores read out data via a PCI express bus (PCIe) into an external disk. It also computes the Fast Fourier Transform of the acquired read out signal: this allows extrapolating which KID interacted and the energy of the impinging radiation. Simulations and tests have been performed successfully and experimental results are presented.

  5. Bridge monitoring based on smart sensor data acquisition system

    NASA Astrophysics Data System (ADS)

    Ehrlich, Jacques; Eymard, Robert; Coche, Georges

    1996-04-01

    The knowledge of loads applied to bridges has to be enhanced in order to actualize national and international codes, like Eurocodes. The nature of traffic loads is extremely complex including such phenomena as dynamic effects, random distribution of damping techniques over the actual trucks, multiple non-linear visco-elastic links in mechanical description of a given truck. For all these reasons, a system of monitoring bridges has been preferred to an unrigorous modelling, in order to get a statistical knowledge of the traffic loads applied to the bridge over large periods. This knowledge under the form of histograms will be useful in order to evaluate extreme load effects and fatigue load effects over the lifetime of the bridge. To achieve these goals, a data acquisition system based on smart sensors extracting and classifying extrema in the traffic loads signal has been developed. At each measurement site a small microsystem is dedicated to the tasks of signal conditioning and sampling, calculation and communication. Each smart sensor can communicate through a numerical data link with its neighbors or with a PC based system controller. In this paper an outline of the problem, the proposed solution based on the smart sensor paradigm, and the results which have been obtained are presented.

  6. Online Monitor Framework for Network Distributed Data Acquisition Systems

    NASA Astrophysics Data System (ADS)

    Konno, Tomoyuki; Cabrera, Anatael; Ishitsuka, Masaki; Kuze, Masahiro; Sakamoto, Yasunobu; the Double Chooz Collaboration

    Data acquisition (DAQ) systems for recent high energy physics experiments consist of lots of subsystems distributed in the local area network. Therefore, scalability for the number of connections from subsystems and availability of access via the Internet are required. "Online monitor framework" is a general software framework for online data monitoring, which provides a way to collect monitoring information distributed in the network and pass them though the firewalls. The framework consists of two subsystems; "Monitor Sever" and "Monitor Viewer". Monitor Server is a core system of the framework. The server collects monitoring information from the DAQ subsystems to provide them to Monitor Viewer. Monitor Viewer is a graphical user interface of the monitor framework, which displays plots in itself. We adapted two types of technologies; Java and HTML5 with Google Web Toolkit, which are independent of operating systems or plugin-libraries like ROOT and contain some functionalities of communicating via the Internet and drawing graphics. The monitoring framework was developed for the Double Chooz reactor neutrino oscillation experiment but is general enough for other experiments. This document reports the structure of the online monitor framework with some examples from the adaption to the Double Chooz experiment.

  7. Web-based data acquisition and management system for GOSAT validation Lidar data analysis

    NASA Astrophysics Data System (ADS)

    Okumura, Hiroshi; Takubo, Shoichiro; Kawasaki, Takeru; Abdullah, Indra N.; Uchino, Osamu; Morino, Isamu; Yokota, Tatsuya; Nagai, Tomohiro; Sakai, Tetsu; Maki, Takashi; Arai, Kohei

    2012-11-01

    An web-base data acquisition and management system for GOSAT (Greenhouse gases Observation SATellite) validation lidar data analysis is developed. The system consists of data acquisition sub-system (DAS) and data management sub-system (DMS). DAS written in Perl language acquires AMeDAS ground-level meteorological data, Rawinsonde upper-air meteorological data, ground-level oxidant data, skyradiometer data, skyview camera images, meteorological satellite IR image data and GOSAT validation lidar data. DMS written in PHP language demonstrates satellite-pass date and all acquired data.

  8. Electronics and data acquisition system for the ICAL prototype detector of India-based neutrino observatory

    NASA Astrophysics Data System (ADS)

    Behere, A.; Bhuyan, M.; Chandratre, V. B.; Dasgupta, S.; Datar, V. M.; Kalmani, S. D.; Lahamge, S. M.; Mondal, N. K.; Mukhopadhyay, P. K.; Nagaraj, P.; Nagesh, B. K.; Pal, S.; Rao, Shobha K.; Samuel, D.; Saraf, M. N.; Satyanarayana, B.; Shastrakar, R. S.; Shinde, R. R.; Sudheer, K. M.; Upadhya, S. S.; Verma, P.

    2013-02-01

    The India-based Neutrino Observatory (INO) collaboration has proposed to build a 50 kton magnetized Iron Calorimeter (ICAL) detector with the primary goal to study neutrino oscillations, employing Resistive Plate Chambers (RPCs) as active detector elements. A prototype of the ICAL detector has been built in order to develop and characterize the intrinsic sub-systems, like RPCs, gas system, electronics and data acquisition system, etc. This paper describes in detail the readout electronics as well as the VME-based data acquisition system for the prototype detector.

  9. Portable High-Frequency Data-Acquisition System

    NASA Technical Reports Server (NTRS)

    Mustain, Roy W.

    1990-01-01

    Compact unit made of readily available solid-state components. Proposed system for acquisition of rapidly changing data self-contained and portable. Conceived for monitoring such aerodynamic effects as flutter, vibration, shock, sound, and pressure. Offers precise and fast acquisition of data and large data-storage capacity: has maximum sampling rate of 125 kHz, access time of 15 ns, and 1-million-bit memory. Measures time with "smart" (microprocessor-controlled) watch that maintains calendar time for more than 10 years without external power. Provides standby power from "smart" battery furnishing up to 1 ampere-hour of charge if power from main batteries lost.

  10. Context-specific comparison of sleep acquisition systems in Drosophila

    PubMed Central

    Garbe, David S.; Bollinger, Wesley L.; Vigderman, Abigail; Masek, Pavel; Gertowski, Jill; Sehgal, Amita; Keene, Alex C.

    2015-01-01

    ABSTRACT Sleep is conserved across phyla and can be measured through electrophysiological or behavioral characteristics. The fruit fly, Drosophila melanogaster, provides an excellent model for investigating the genetic and neural mechanisms that regulate sleep. Multiple systems exist for measuring fly activity, including video analysis and single-beam (SB) or multi-beam (MB) infrared (IR)-based monitoring. In this study, we compare multiple sleep parameters of individual flies using a custom-built video-based acquisition system, and commercially available SB- or MB-IR acquisition systems. We report that all three monitoring systems appear sufficiently sensitive to detect changes in sleep duration associated with diet, age, and mating status. Our data also demonstrate that MB-IR detection appeared more sensitive than the SB-IR for detecting baseline nuances in sleep architecture, while architectural changes associated with varying life-history and environment were generally detected across all acquisition types. Finally, video recording of flies in an arena allowed us to measure the effect of ambient environment on sleep. These experiments demonstrate a robust effect of arena shape and size as well as light levels on sleep duration and architecture, and highlighting the versatility of tracking-based sleep acquisition. These findings provide insight into the context-specific basis for choosing between Drosophila sleep acquisition systems, describe a novel cost-effective system for video tracking, and characterize sleep analysis using the MB-IR sleep analysis. Further, we describe a modified dark-place preference sleep assay using video tracking, confirming that flies prefer to sleep in dark locations. PMID:26519516

  11. Ultimate visible band panorama acquisition system

    NASA Astrophysics Data System (ADS)

    Brown, Wade W.; Thomas, David J.; Reynolds, William R.

    2002-08-01

    The current state of the art in synthetic radiometrically accurate scene generation for visual signatures remains immature. Even more difficult is creating composite images of photo-realistic synthetic images placed into images of real scenes. A potential solution to this problem is to use measured background data to drive the target rendering process. This approach has the advantage of deriving synthetic images with sufficient fidelity for inputs into the visual laboratory and performance codes. Since scene luminance can change rapidly, especially during partly cloudy conditions, all measurements must be obtained nearly simultaneously. This paper will explore the requirements for a visual predictive code and meeting these requirements with a background measurement process. A prototype measurement system will be described along with results from measurements.

  12. Development and application of General Purpose Data Acquisition Shell (GPDAS) at advanced photon source

    SciTech Connect

    Chung, Youngjoo; Kim, Keeman.

    1991-01-01

    An operating system shell GPDAS (General Purpose Data Acquisition Shell) on MS-DOS-based microcomputers has been developed to provide flexibility in data acquisition and device control for magnet measurements at the Advanced Photon Source. GPDAS is both a command interpreter and an integrated script-based programming environment. It also incorporates the MS-DOS shell to make use of the existing utility programs for file manipulation and data analysis. Features include: alias definition, virtual memory, windows, graphics, data and procedure backup, background operation, script programming language, and script level debugging. Data acquisition system devices can be controlled through IEEE488 board, multifunction I/O board, digital I/O board and Gespac crate via Euro G-64 bus. GPDAS is now being used for diagnostics R D and accelerator physics studies as well as for magnet measurements. Their hardware configurations will also be discussed. 3 refs., 3 figs.

  13. Harpoon-based sample Acquisition System

    NASA Astrophysics Data System (ADS)

    Bernal, Javier; Nuth, Joseph; Wegel, Donald

    2012-02-01

    Acquiring information about the composition of comets, asteroids, and other near Earth objects is very important because they may contain the primordial ooze of the solar system and the origins of life on Earth. Sending a spacecraft is the obvious answer, but once it gets there it needs to collect and analyze samples. Conceptually, a drill or a shovel would work, but both require something extra to anchor it to the comet, adding to the cost and complexity of the spacecraft. Since comets and asteroids are very low gravity objects, drilling becomes a problem. If you do not provide a grappling mechanism, the drill would push the spacecraft off the surface. Harpoons have been proposed as grappling mechanisms in the past and are currently flying on missions such as ROSETTA. We propose to use a hollow, core sampling harpoon, to act as the anchoring mechanism as well as the sample collecting device. By combining these two functions, mass is reduced, more samples can be collected and the spacecraft can carry more propellant. Although challenging, returning the collected samples to Earth allows them to be analyzed in laboratories with much greater detail than possible on a spacecraft. Also, bringing the samples back to Earth allows future generations to study them.

  14. CAPTAN: A hardware architecture for integrated data acquisition, control, and analysis for detector development

    SciTech Connect

    Turqueti, Marcos; Rivera, Ryan A.; Prosser, Alan; Andresen, Jeffry; Chramowicz, John; /Fermilab

    2008-11-01

    The Electronic Systems Engineering Department of the Computing Division at the Fermi National Accelerator Laboratory has developed a data acquisition system flexible and powerful enough to meet the needs of a variety of high energy physics applications. The system described in this paper is called CAPTAN (Compact And Programmable daTa Acquisition Node) and its architecture and capabilities are presented in detail here. The three most important characteristics of this system are flexibility, versatility and scalability. These three main features are supported by key architectural features; a vertical bus that permits the user to stack multiple boards, a gigabit Ethernet link that permits high speed communications to the system and the core group of boards that provide specific capabilities for the system. In this paper, we describe the system architecture, give an overview of its capabilities and point out possible applications.

  15. The application of windows multithread in high-speed continual large-capacity data acquisition system

    NASA Astrophysics Data System (ADS)

    Wang, Tai-Yong; Zeng, Ju-Xiang; He, Hui-Long; Deng, Hui

    2005-12-01

    Three modes of Windows Multithread techniques in data acquisition system are explored in this paper. In the first mode, data acquisition is in one thread while the processing and display of data and the large-capacity data saving share another thread. In the second mode, data acquisition and the data processing and display are in one thread, and the large-capacity data saving in another thread. In the third mode, double level buffer queue technology is added based on the first mode technique. Experiments on the data acquisition system reveal that the third mode is the optimal alternative. It fully utilizes the capacity of data acquisition card and makes access to high-speed continual data acquisition and large-capacity data saving. The monitoring system which adopts the third mode has been developed and applied to some urban waterworks in Shanghai which has been in good mode during the past two years and saved a vast sum of costs on system maintenance and monitoring.

  16. Acquisition of thermotolerance during development of Blastocladiella emersonii.

    PubMed

    Silva, A M; Juliani, M H; da Costa, J J; Bonato, M C

    1987-04-14

    In the fungus Blastocladiella emersonii the synthesis of heat-shock proteins is developmentally regulated; particular subsets of heat-shock proteins are induced by heat shock during sporulation, germination and growth and some heat shock-related proteins are spontaneously expressed during sporulation (Bonato et al., 1987, Eur. J. Biochem., in press). Nevertheless, acquisition of thermotolerance can be induced at any stage of the life cycle. The development of thermotolerance is correlated with the enhanced synthesis of some heat-shock proteins: hsp 82a, hsp 82b, hsp 76, hsp 70, hsp 60, hsp 25, hsp 17b. Other hsps are not specifically involved in thermotolerance. PMID:3579921

  17. All-around convergent view acquisition system using ellipsoidal mirrors

    NASA Astrophysics Data System (ADS)

    Takeda, Gentaro; Yendo, Tomohiro; Tehrani, Mehrdad Panahpour; Fujii, Toshiaki; Tanimoto, Masayuki

    2010-04-01

    In this paper, we present a new image acquisition system for FTV (Free-viewpoint TV). The proposed system can capture the dynamic scene from all-around views. The proposed system consists of two ellipsoidal mirrors, a high-speed camera, and a rotating aslope mirror. As for two ellipsoidal mirrors, the size and the ellipticity are mutually different. The object is set in the focus of ellipsoidal mirror. The size of this system is smaller than that of early system since ellipsoidal mirrors can reduce virtual images. High-speed camera can acquire multi viewpoint images by mirror scanning. Here, we simulated this system with ray tracing and confirmed the principle.

  18. Naval Underwater Systems Center torpedo data acquisition system design update

    SciTech Connect

    Adams, D.J.; Beshears, D.L.; Capps, G.J.; Jordan, J.K.; Napier, R.W.; Ott, G.W.; Scudiere, M.B.; White, C.P.; Nodine, R.N.; Todd, R.A.

    1988-10-01

    In the process of developing technology for torpedo applications, the Naval Underwater Systems Center test vehicles are instrumented with sensors (and signal processors), and their outputs are recorded during in water exercises. This paper defines the design for both the wet'' and dry'' systems. The wet system will be the on-board torpedo equipment used to monitor and record a multitude of transducer of transducer signals. The dry system will be used for programming the wet system, handling the test data, and performing quick-look signal analyses. The system will be used to monitor, record, and analyze an enormous volume of data from transducer signals during either routine or development in-water exercises. 24 figs.

  19. DDS-Suite - A Dynamic Data Acquisition, Processing, and Analysis System for Wind Tunnel Testing

    NASA Technical Reports Server (NTRS)

    Burnside, Jathan J.

    2012-01-01

    Wind Tunnels have optimized their steady-state data systems for acquisition and analysis and even implemented large dynamic-data acquisition systems, however development of near real-time processing and analysis tools for dynamic-data have lagged. DDS-Suite is a set of tools used to acquire, process, and analyze large amounts of dynamic data. Each phase of the testing process: acquisition, processing, and analysis are handled by separate components so that bottlenecks in one phase of the process do not affect the other, leading to a robust system. DDS-Suite is capable of acquiring 672 channels of dynamic data at rate of 275 MB / s. More than 300 channels of the system use 24-bit analog-to-digital cards and are capable of producing data with less than 0.01 of phase difference at 1 kHz. System architecture, design philosophy, and examples of use during NASA Constellation and Fundamental Aerodynamic tests are discussed.

  20. Multi-tier approach for data acquisition programming in the TJ-II remote participation system

    NASA Astrophysics Data System (ADS)

    Vega, J.; Sánchez, E.; Portas, A.; Ruiz, M.; Barrera, E.; López, S.

    2004-10-01

    Programming software to setup acquisition channels during device operation has been developed for the TJ-II remote participation system. The software follows a three-tier model. A first tier (client tier) groups client software containing only user interface code. A second tier (middle tier) includes code for authorization, authentication, and query processing. A third tier (data tier) consists of a relational database server for managing configurations. Multi-platform characteristics are provided by web browsers (client tier) and web servers (middle tier). This architecture avoids that data acquisition system controllers provide access control, database support, or graphic user interface resources. Therefore, computation capabilities of these systems can mainly be devoted to data handling. LabView (from National Instruments) has been used as programming language in the acquisition systems. This design allows a very transparent management of signals, independently on hardware modules and systems.

  1. New developments in electron microscopy for serial image acquisition of neuronal profiles.

    PubMed

    Kubota, Yoshiyuki

    2015-02-01

    Recent developments in electron microscopy largely automate the continuous acquisition of serial electron micrographs (EMGs), previously achieved by laborious manual serial ultrathin sectioning using an ultramicrotome and ultrastructural image capture process with transmission electron microscopy. The new systems cut thin sections and capture serial EMGs automatically, allowing for acquisition of large data sets in a reasonably short time. The new methods are focused ion beam/scanning electron microscopy, ultramicrotome/serial block-face scanning electron microscopy, automated tape-collection ultramicrotome/scanning electron microscopy and transmission electron microscope camera array. In this review, their positive and negative aspects are discussed. PMID:25564566

  2. Data acquisition system for phase-2 KGF proton decay experiment

    NASA Technical Reports Server (NTRS)

    Krishnaswamy, M. R.; Menon, M. G. K.; Ito, N.; Kawakami, S.; Mondal, N. K.; Narasimham, V. S.; Sreekantan, B. V.; Hayashi, Y.; Miyake, S.

    1985-01-01

    Phase-2 of KGF proton decay experiment using 4000 proportional counters will start operating from middle of 1985. The detection systems, in addition to measuring the time information to an accuracy of 200 n see, also records ionization in the hit counters. It also monitors different characteristics of the counters like pulse height spectrum, pulse width spectrum and counting rate. The acquisition system is discussed.

  3. Acquisition and sources. [documents for scientific and technical information systems

    NASA Technical Reports Server (NTRS)

    Eckert, P. F.

    1978-01-01

    Suggestions and ideas for acquiring documents or their surrogates for a planned or fledgling information system are offered. The problems of selectivity of documents or their surrogates, both in superabundant quantities, and duplicate checking are highlighted. Acquisitioning flow, a semiautomated duplicate search technique, and alerting methods for prospective documentation are described. Appendices include two category systems, selected definitions and acronyms, and a selected address list for document procurement.

  4. A flexible computerized system for environmental data acquisition and transmission

    NASA Astrophysics Data System (ADS)

    Zappalà, G.

    2009-04-01

    In recent years increasing importance has been addressed to the knowledge of the marine environment, either to help detecting and understanding global climate change phenomena, or to protect and preserve those coastal areas, where multiple interests converge (linked to the tourism, recreational or productive activities…) and which suffer greater impact from anthropogenic activities; this has in turn stimulated the start of research programs devoted to the monitoring and surveillance of these particular zones, coupling the needs for knowledge, sustainable development and exploitation of natural resources. There is an increasing need to have data available in real time or near real time in order to intervene in emergency situations. Cabled or wireless data transmission can be used. The first allows the transmission of a higher amount of data only in coastal sites, while the second gives a bigger flexibility in terms of application to different environments; more, using mobile phone services (either terrestrial or satellite), it is possible to allocate the data centre in the most convenient place, without any need of proximity to the sea. Traditional oceanographic techniques, based on ship surveys, hardly fit the needs of operational oceanography, because of their high cost and fragmentary nature, both in spatial and temporal domains. To obtain a good synopticity, it is necessary to complement traditional ship observations with measurements from fixed stations (buoys moored in sites chosen to be representative of wider areas, or to constitute a sentinel against the arrival of pollutants), satellite observations, use of ships of opportunity and of newly developed instruments, like the gliders, or towed sliding devices, like the SAVE. Modern instruments rely on an electronic heart; an integrated hardware-software system developed in Messina is here presented, used in various versions to control data acquisition and transmission on buoys or on ship

  5. State transition storyboards: A tool for designing the Goldstone solar system radar data acquisition system user interface software

    NASA Technical Reports Server (NTRS)

    Howard, S. D.

    1987-01-01

    Effective user interface design in software systems is a complex task that takes place without adequate modeling tools. By combining state transition diagrams and the storyboard technique of filmmakers, State Transition Storyboards were developed to provide a detailed modeling technique for the Goldstone Solar System Radar Data Acquisition System human-machine interface. Illustrations are included with a description of the modeling technique.

  6. TDAS: The Thermal Expert System (TEXSYS) data acquisition system

    NASA Technical Reports Server (NTRS)

    Hack, Edmund C.; Healey, Kathleen J.

    1987-01-01

    As part of the NASA Systems Autonomy Demonstration Project, a thermal expert system (TEXSYS) is being developed. TEXSYS combines a fast real time control system, a sophisticated human interface for the user and several distinct artificial intelligence techniques in one system. TEXSYS is to provide real time control, operations advice and fault detection, isolation and recovery capabilities for the space station Thermal Test Bed (TTB). TEXSYS will be integrated with the TTB and act as an intelligent assistant to thermal engineers conducting TTB tests and experiments. The results are presented from connecting the real time controller to the knowledge based system thereby creating an integrated system. Special attention will be paid to the problem of filtering and interpreting the raw, real time data and placing the important values into the knowledge base of the expert system.

  7. Acquisition of arbitrary conditional discriminations by young normally developing children.

    PubMed Central

    Pilgrim, C; Jackson, J; Galizio, M

    2000-01-01

    Three experiments investigated conditions designed to facilitate acquisition of arbitrary conditional discriminations in 3- to 6-year-old normally developing children. In Experiment 1, 6 subjects failed to master the arbitrary match-to-sample task under conditions of differential reinforcement alone, but 7 subjects did so when instructions or instructions and sample naming were added. In Experiment 2, sample naming introduced in a blocked-trial arrangement resulted in acquisition, but only when the sample name was a nonsense syllable provided by the experimenter (5 of 7 subjects) and not when the sample name was generated by the subject (0 of 5 subjects). Experiment 3 demonstrated the effectiveness of a training sequence involving thematically related stimuli as an intermediate step facilitating the transition from identity to novel arbitrary relations. The difficulties in mastering arbitrary conditional discriminations shown here imply that further analyses with young children will be particularly important in efforts to investigate the development of theoretically important stimulus relations. PMID:10784008

  8. Acquisition of Scientific Literature in Developing Countries. 2: Malaysia.

    ERIC Educational Resources Information Center

    Taib, Rosna

    1989-01-01

    Describes the acquisition of scientific literature by academic libraries in Malaysia. The discussion covers the impact of government policies, library acquisition policies, the selection process, acquisition of special materials, the role of gifts and exchanges, and problems with customs clearance and censorship. Progress in cooperative…

  9. Acquisition and tracking performance measurements for a high speed area array detector system

    NASA Technical Reports Server (NTRS)

    Short, R. C.; Cosgrove, M.; Clark, D. L.; Martino, A.; Park, H.; Seery, B.

    1991-01-01

    A proof-of-concept (POC) demonstration system has been developed which demonstrates acquisition, tracking and point-ahead angle sensing for a space optical communications terminal utilizing a single high speed area array detector. The detector is the 128 x 128 pixel Kodak HS-40 photodiode array. It has 64 parallel readout channels and can operate at frames rates up to 40,000 frames/sec with rms readout noise of 20 photoelectrons. A windowing scheme and special purpose digital signal processing electronics are employed to implement acquisition and tracking algorithms. The system operates at greater than 1 kHz sample (frame) rates. Acquisition can be performed in as little as 30 milliseconds with less than 1 picowatt of 0.85 micron beacon power on the detector. At the same power level, the rms tracking accuracy is approximately 1/16 pixel. Results of system analysis and measurements using the POC system are presented.

  10. A Data Acquisition System (DAS) for marine and ecological research from aerospace technology

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1972-01-01

    The efforts of researchers at Mississippi State University to utilize space-age technology in the development of a self-contained, portable data acquisition system for use in marine and ecological research are presented. The compact, lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing.

  11. Sample Acquisition and Handling System from a Remote Platform

    NASA Technical Reports Server (NTRS)

    Badescu, Mircea; Sherrit, Stewart; Jones, Jack A.

    2011-01-01

    A system has been developed to acquire and handle samples from a suspended remote platform. The system includes a penetrator, a penetrator deployment mechanism, and a sample handler. A gravity-driven harpoon sampler was used for the system, but other solutions can be used to supply the penetration energy, such as pyrotechnic, pressurized gas, or springs. The deployment mechanism includes a line that is attached to the penetrator, a spool for reeling in the line, and a line engagement control mechanism. The penetrator has removable tips that can collect liquid, ice, or solid samples. The handling mechanism consists of a carousel that can store a series of identical or different tips, assist in penetrator reconfiguration for multiple sample acquisition, and deliver the sample to a series of instruments for analysis. The carousel sample handling system was combined with a brassboard reeling mechanism and a penetrator with removable tips. It can attach the removable tip to the penetrator, release and retrieve the penetrator, remove the tip, and present it to multiple instrument stations. The penetrator can be remotely deployed from an aerobot, penetrate and collect the sample, and be retrieved with the sample to the aerobot. The penetrator with removable tips includes sample interrogation windows and a sample retainment spring for unconsolidated samples. The line engagement motor can be used to control the penetrator release and reeling engagement, and to evenly distribute the line on the spool by rocking between left and right ends of the spool. When the arm with the guiding ring is aligned with the spool axis, the line is free to unwind from the spool without rotating the spool. When the arm is perpendicular to the spool axis, the line can move only if the spool rotates.

  12. A personal computer-based, multitasking data acquisition system

    NASA Technical Reports Server (NTRS)

    Bailey, Steven A.

    1990-01-01

    A multitasking, data acquisition system was written to simultaneously collect meteorological radar and telemetry data from two sources. This system is based on the personal computer architecture. Data is collected via two asynchronous serial ports and is deposited to disk. The system is written in both the C programming language and assembler. It consists of three parts: a multitasking kernel for data collection, a shell with pull down windows as user interface, and a graphics processor for editing data and creating coded messages. An explanation of both system principles and program structure is presented.

  13. The data acquisition system for the crystal ball at LNS

    NASA Astrophysics Data System (ADS)

    Finocchiaro, P.; Maiolino, C.; Piattelli, P.

    1988-09-01

    In this paper we describe the actual status of the data acquisition system for the Crystal Ball 4π detector to be installed at LNS. We describe in some detail the open architecture required to ensure the possible future extensions of the system. Noticeable is the fact that this system is not bound to any particular kind of computer or software: the only fixed components of the architecture are the VME-bus for the computer systems and the FERA-bus for the fast transfer of the digitalized data.

  14. Number-Concept Acquisition and General Vocabulary Development

    PubMed Central

    Negen, James; Sarnecka, Barbara W.

    2012-01-01

    How is number-concept acquisition related to overall language development? Experiments 1 and 2 measured number-word knowledge and general vocabulary in a total of 59 children, ages 30 to 60 months. A strong correlation was found between number-word knowledge and vocabulary, independent of the child’s age, contrary to previous results (Ansari et al., 2003). This result calls into question arguments that (a) the number-concept creation process is scaffolded mainly by visuo-spatial development, and (b) that language only becomes integrated after the concepts are created (ibid). Instead, this may suggest that having a larger nominal vocabulary helps children learn number words. Experiment 3 shows that the differences with previous results are likely due to changes in how the data were analyzed. PMID:22803603

  15. Modeling the development of pronunciation in infant speech acquisition.

    PubMed

    Howard, Ian S; Messum, Piers

    2011-01-01

    Pronunciation is an important part of speech acquisition, but little attention has been given to the mechanism or mechanisms by which it develops. Speech sound qualities, for example, have just been assumed to develop by simple imitation. In most accounts this is then assumed to be by acoustic matching, with the infant comparing his output to that of his caregiver. There are theoretical and empirical problems with both of these assumptions, and we present a computational model- Elija-that does not learn to pronounce speech sounds this way. Elija starts by exploring the sound making capabilities of his vocal apparatus. Then he uses the natural responses he gets from a caregiver to learn equivalence relations between his vocal actions and his caregiver's speech. We show that Elija progresses from a babbling stage to learning the names of objects. This demonstrates the viability of a non-imitative mechanism in learning to pronounce. PMID:21339516

  16. A research of a high precision multichannel data acquisition system

    NASA Astrophysics Data System (ADS)

    Zhong, Ling-na; Tang, Xiao-ping; Yan, Wei

    2013-08-01

    The output signals of the focusing system in lithography are analog. To convert the analog signals into digital ones which are more flexible and stable to process, a desirable data acquisition system is required. The resolution of data acquisition, to some extent, affects the accuracy of focusing. In this article, we first compared performance between the various kinds of analog-to-digital converters (ADC) available on the market at the moment. Combined with the specific requirements (sampling frequency, converting accuracy, numbers of channels etc) and the characteristics (polarization, amplitude range etc) of the analog signals, the model of the ADC to be used as the core chip in our hardware design was determined. On this basis, we chose other chips needed in the hardware circuit that would well match with ADC, then the overall hardware design was obtained. Validation of our data acquisition system was verified through experiments and it can be demonstrated that the system can effectively realize the high resolution conversion of the multi-channel analog signals and give the accurate focusing information in lithography.

  17. Two Axis Pointing System (TAPS) attitude acquisition, determination, and control

    NASA Technical Reports Server (NTRS)

    Azzolini, John D.; Mcglew, David E.

    1990-01-01

    The Two Axis Pointing System (TAPS) is a 2 axis gimbal system designed to provide fine pointing of Space Transportation System (STS) borne instruments. It features center-of-mass instrument mounting and will accommodate instruments of up to 1134 kg (2500 pounds) which fit within a 1.0 by 1.0 by 4.2 meter (40 by 40 by 166 inch) envelope. The TAPS system is controlled by a microcomputer based Control Electronics Assembly (CEA), a Power Distribution Unit (PDU), and a Servo Control Unit (SCU). A DRIRU-II inertial reference unit is used to provide incremental angles for attitude propagation. A Ball Brothers STRAP star tracker is used for attitude acquisition and update. The theory of the TAPS attitude determination and error computation for the Broad Band X-ray Telescope (BBXRT) are described. The attitude acquisition is based upon a 2 star geometric solution. The acquisition theory and quaternion algebra are presented. The attitude control combines classical position, integral and derivative (PID) control with techniques to compensate for coulomb friction (bias torque) and the cable harness crossing the gimbals (spring torque). Also presented is a technique for an adaptive bias torque compensation which adjusts to an ever changing frictional torque environment. The control stability margins are detailed, with the predicted pointing performance, based upon simulation studies. The TAPS user interface, which provides high level operations commands to facilitate science observations, is outlined.

  18. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    SciTech Connect

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  19. LoFASM's FPGA-based Digital Acquisition System

    NASA Astrophysics Data System (ADS)

    Dartez, Louis P.; Jenet, F.; Creighton, T. D.; Ford, A. J.; Hicks, B.; Hinojosa, J.; Kassim, N. E.; Price, R. H.; Stovall, K.; Ray, P. S.; Taylor, G. B.

    2014-01-01

    The Low Frequency All Sky Monitor (LoFASM) is a distributed array of dipole antennas that are sensitive to radio frequencies from 10 to 88 MHz. LoFASM consists of antennas and front end electronics that were originally developed for the Long Wavelength Array (LWA) by the U.S. Naval Research Lab, the University of New Mexico, Virginia Tech, and the Jet Propulsion Laboratory. LoFASM, funded by the U.S. Department of Defense, will initially consist of 4 stations, each consisting of 12 dual-polarization dipole antenna stands. The primary science goals of LoFASM will be the detection and study of low-frequency radio transients, a high priority science goal as deemed by the National Research Council's decadal survey. The data acquisition system for the LoFASM antenna array will be using Field Programmable Gate Array (FPGA) technology to implement a real time full Stokes spectrometer and data recorder. This poster presents an overview of the current design and digital architecture of a single station of the LoFASM array as well as the status of the entire project.

  20. Novel Aspects of the DESI Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Beaufore, Lucas; Honscheid, Klaus; Elliott, Ann; Dark Energy Spectroscopic Instrument Collaboration

    2015-04-01

    The Dark Energy Spectroscopic Instrument (DESI) will measure the effect of dark energy on the expansion of the universe. It will obtain optical spectra for tens of millions of galaxies and quasars, constructing a 3-dimensional map spanning the nearby universe to 10 billion light years. The survey will be conducted on the Mayall 4-meter telescope at Kitt Peak National Observatory starting in 2018. In order to achieve these scientific goals the DESI collaboration is building a high throughput spectrograph capable of observing thousands of spectra simultaneously. In this presentation we discuss the DESI instrument control and data acquisition system that is currently being developed to operate the 5,000 fiber positioners in the focal plane, the 10 spectrographs each with three CDD cameras and every other aspect of the instrument. Special emphasis will be given to novel aspects of the design including the use of inexpensive Linux-based microcontrollers such as the Raspberry PI to control a number of DESI hardware components.

  1. Teaching Skill Acquisition and Development in Dental Education.

    PubMed

    Lyon, Lucinda J; Hoover, Terry E; Giusti, Lola; Booth, Mark T; Mahdavi, Elham

    2016-08-01

    Development of dental faculty members is paramount to providing outstanding education and role modeling for students. With the large number of second career educators in dental schools, an efficient method of acquiring teaching skills is important for new faculty members. Knowing the skill progression and learning experiences identified by dental educators of varying rank may lead to more efficient, effective faculty development. The aims of this study were to identify the perceptions of a group of faculty members about the knowledge, skills, attitudes, and learning experiences that contribute to developing teaching expertise and to compare and contrast the perceptions of new and more senior faculty members on these subjects. The Dreyfus skill acquisition continuum of novice to expert performance was used as a construct reference. The study used a mixed-methods approach in which qualitative and quantitative data were collected concurrently in an electronic survey of faculty members at one U.S. dental school. Of the 492 total faculty members, 80 survey responses were received, for a 16% response rate. Open coding and analysis of responses revealed some common themes. Building rich content knowledge and learning varied methodologies for teaching and assessment, supported by an awareness of peer role models, were perceived to be features of early growth. Content prioritization, clarity, and customization appropriate for the learner characterized mid growth. As theorized in the Dreyfus model, more experienced faculty members described a fluid, less structured teaching process, increased reflection, and appreciation of the strength of the educational community. The results of this study may help increase dental educators' understanding of teaching skill acquisition and inform faculty development and support. PMID:27480710

  2. Data acquisition system for X-ray free-electron laser experiments at SACLA

    PubMed Central

    Joti, Yasumasa; Kameshima, Takashi; Yamaga, Mitsuhiro; Sugimoto, Takashi; Okada, Kensuke; Abe, Toshinori; Furukawa, Yukito; Ohata, Toru; Tanaka, Ryotaro; Hatsui, Takaki; Yabashi, Makina

    2015-01-01

    A data acquisition system for X-ray free-electron laser experiments at SACLA has been developed. The system has been designed for reliable shot-to-shot data storage with a high data stream greater than 4 Gbps and massive data analysis. Configuration of the system and examples of prompt data analysis during experiments are presented. Upgrade plans for the system to extend flexibility are described. PMID:25931070

  3. Multi-channel data acquisition system with absolute time synchronization

    NASA Astrophysics Data System (ADS)

    Włodarczyk, Przemysław; Pustelny, Szymon; Budker, Dmitry; Lipiński, Marcin

    2014-11-01

    We present a low-cost, stand-alone global-time-synchronized data acquisition system. Our prototype allows recording up to four analog signals with a 16-bit resolution in variable ranges and a maximum sampling rate of 1000 S/s. The system simultaneously acquires readouts of external sensors e.g. magnetometer or thermometer. A complete data set, including a header containing timestamp, is stored on a Secure Digital (SD) card or transmitted to a computer using Universal Serial Bus (USB). The estimated time accuracy of the data acquisition is better than ±200 ns. The device is intended for use in a global network of optical magnetometers (the Global Network of Optical Magnetometers for Exotic physics - GNOME), which aims to search for signals heralding physics beyond the Standard Model, that can be generated by ordinary spin coupling to exotic particles or anomalous spin interactions.

  4. Development of a single-shot CCD-based data acquisition system for time-resolved X-ray photoelectron spectroscopy at an X-ray free-electron laser facility.

    PubMed

    Oura, Masaki; Wagai, Tatsuya; Chainani, Ashish; Miyawaki, Jun; Sato, Hiromi; Matsunami, Masaharu; Eguchi, Ritsuko; Kiss, Takayuki; Yamaguchi, Takashi; Nakatani, Yasuhiro; Togashi, Tadashi; Katayama, Tetsuo; Ogawa, Kanade; Yabashi, Makina; Tanaka, Yoshihito; Kohmura, Yoshiki; Tamasaku, Kenji; Shin, Shik; Ishikawa, Tetsuya

    2014-01-01

    In order to utilize high-brilliance photon sources, such as X-ray free-electron lasers (XFELs), for advanced time-resolved photoelectron spectroscopy (TR-PES), a single-shot CCD-based data acquisition system combined with a high-resolution hemispherical electron energy analyzer has been developed. The system's design enables it to be controlled by an external trigger signal for single-shot pump-probe-type TR-PES. The basic performance of the system is demonstrated with an offline test, followed by online core-level photoelectron and Auger electron spectroscopy in 'single-shot image', 'shot-to-shot image (image-to-image storage or block storage)' and `shot-to-shot sweep' modes at soft X-ray undulator beamline BL17SU of SPring-8. In the offline test the typical repetition rate for image-to-image storage mode has been confirmed to be about 15 Hz using a conventional pulse-generator. The function for correcting the shot-to-shot intensity fluctuations of the exciting photon beam, an important requirement for the TR-PES experiments at FEL sources, has been successfully tested at BL17SU by measuring Au 4f photoelectrons with intentionally controlled photon flux. The system has also been applied to hard X-ray PES (HAXPES) in `ordinary sweep' mode as well as shot-to-shot image mode at the 27 m-long undulator beamline BL19LXU of SPring-8 and also at the SACLA XFEL facility. The XFEL-induced Ti 1s core-level spectrum of La-doped SrTiO3 is reported as a function of incident power density. The Ti 1s core-level spectrum obtained at low power density is consistent with the spectrum obtained using the synchrotron source. At high power densities the Ti 1s core-level spectra show space-charge effects which are analysed using a known mean-field model for ultrafast electron packet propagation. The results successfully confirm the capability of the present data acquisition system for carrying out the core-level HAXPES studies of condensed matter induced by the XFEL. PMID:24365935

  5. Proposal to upgrade the MIPP data acquisition system

    SciTech Connect

    Baker, W.; Carey, D.; Johnstone, C.; Kostin, M.; Meyer, H.; Raja, R.; /Fermilab

    2005-03-01

    The MIPP TPC is the largest contributor to the MIPP event size by far. Its readout system and electronics were designed in the 1990's and limit it to a readout rate of 60 Hz in simple events and {approx} 20 Hz in complicated events. With the readout chips designed for the ALICE collaboration at the LHC, we propose a low cost effective scheme of upgrading the MIPP data acquisition speed to 3000 Hz.

  6. Design and implementation of telemetry seismic data acquisition system based on embedded P2P Ethernet

    NASA Astrophysics Data System (ADS)

    Zhang, L.; Lin, J.; Chen, Z.

    2011-12-01

    A new design of telemetry seismic data acquisition system is presented which uses embedded, point to point (P2P) Ethernet networks. In our presentation, we explain the idea and motivation behind the use of P2P Ethernet topology and show the problems when such topology is used in seismic acquisition system. The presented paper focuses on the network protocols developed by us which include the generation of route table and dynamic IP address management. This new design has been implemented based on ARM and FPGA, which we have tested in laboratory and seismic exploration.

  7. High speed COMS image acquisition and transmission system based on USB

    NASA Astrophysics Data System (ADS)

    Cui, Yundong; Jiang, Jie; Zhang, Guangjun

    2008-10-01

    A high speed CMOS image acquisition and transmission system, which is composed of CMOS image sensor IBIS5-A-1300, USB 2.0 interface chip EZ-USB FX2 and FPGA (Field Programmable Gate Array), is designed and developed. The design of IBIS5-A-1300 driving timing, USB interface chip timing, firmware and application program are introduced. Experiments show that the system possesses the advantage of high resolution and high frame rate, supports single frame acquisition and video preview and fits the criterion of USB2.0 and the demand of real-time data transmission.

  8. Dual cameras acquisition and display system of retina-like sensor camera and rectangular sensor camera

    NASA Astrophysics Data System (ADS)

    Cao, Nan; Cao, Fengmei; Lin, Yabin; Bai, Tingzhu; Song, Shengyu

    2015-04-01

    For a new kind of retina-like senor camera and a traditional rectangular sensor camera, dual cameras acquisition and display system need to be built. We introduce the principle and the development of retina-like senor. Image coordinates transformation and interpolation based on sub-pixel interpolation need to be realized for our retina-like sensor's special pixels distribution. The hardware platform is composed of retina-like senor camera, rectangular sensor camera, image grabber and PC. Combined the MIL and OpenCV library, the software program is composed in VC++ on VS 2010. Experience results show that the system can realizes two cameras' acquisition and display.

  9. Knowledge acquisition environment for the design of a decision support system: application in blood transfusion.

    PubMed Central

    Achour, S. L.; Dojat, M.; Rieux, C.; Bierling, P.; Lepage, E.

    1999-01-01

    Blood transfusion is a medical domain where decision support systems (DSSs) could be very helpful to the physicians but must easily and continuously be maintained. We have developed a knowledge acquisition tool that allows the construction and the maintenance of such a system by the domain expert. The methodology used could be applied to another highly evolutive medical domain. In this paper, we detail our knowledge acquisition tool, its use and the final DSS obtained, which is fully integrated into our hospital information network. Images Figure 5 PMID:10566346

  10. Crosscutting Development- EVA Tools and Geology Sample Acquisition

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Exploration to all destinations has at one time or another involved the acquisition and return of samples and context data. Gathered at the summit of the highest mountain, the floor of the deepest sea, or the ice of a polar surface, samples and their value (both scientific and symbolic) have been a mainstay of Earthly exploration. In manned spaceflight exploration, the gathering of samples and their contextual information has continued. With the extension of collecting activities to spaceflight destinations comes the need for geology tools and equipment uniquely designed for use by suited crew members in radically different environments from conventional field geology. Beginning with the first Apollo Lunar Surface Extravehicular Activity (EVA), EVA Geology Tools were successfully used to enable the exploration and scientific sample gathering objectives of the lunar crew members. These early designs were a step in the evolution of Field Geology equipment, and the evolution continues today. Contemporary efforts seek to build upon and extend the knowledge gained in not only the Apollo program but a wealth of terrestrial field geology methods and hardware that have continued to evolve since the last lunar surface EVA. This paper is presented with intentional focus on documenting the continuing evolution and growing body of knowledge for both engineering and science team members seeking to further the development of EVA Geology. Recent engineering development and field testing efforts of EVA Geology equipment for surface EVA applications are presented, including the 2010 Desert Research and Technology Studies (Desert RATs) field trial. An executive summary of findings will also be presented, detailing efforts recommended for exotic sample acquisition and pre-return curation development regardless of planetary or microgravity destination.

  11. An isolated data acquisition system for high voltage applications

    SciTech Connect

    Waitz, A.; Donaldson, A.

    1985-10-01

    This report describes the design and operation of a microcomputer controlled system for acquisition of both analog and binary data within the high voltage stages of a linac modulator. The system is comprised of a microprocessor Controller which communicates with the remote data Acquisition circuits via an optical bus. The bus, which uses a 1 MHz Manchester II format, is configured as a loop, starting at the Controller, daisy-chaining the remote cards and terminating back at the Controller. Upon receiving a linac timing pulse, the Controller sends addressed commands to the individual remote cards and receives data back. It then passes this data to the linac control system through a Multibus connection. Each remote circuit can return 16 binary sense and 7 (12 bit) analog parameters within 270 us. This speed is possible because of a pipelined design where one word is transmitted while another is being converted. A data conversion cycle is initiated when a remote data acquisition card receives the proper command and address from the controller.

  12. Isolated data acquisition system for high voltage applications

    SciTech Connect

    Waitz, A.; Donaldson, A.

    1985-06-01

    This report describes the design and operation of a microcomputer controlled system for acquisition of both analog and binary data within the high voltage stages of a linac modulator. The system is comprised of a microprocessor Controller which communicates with the remote data Acquisition circuits via an optical bus. The bus, which uses a 1 MHz Manchester II format, is configured as a loop, starting at the Controller, daisy-chaining the remote cards and terminating back at the Controller. Upon receiving a linac timing pulse, the Controller sends addressed commands to the individual remote cards and receives data back. It then passes this data to the linac control system through a Multibus connection. Each remote circuit can return 16 binary sense and 7 (12 bit) analog parameters within 270 us. This speed is possible because of a pipelined design where one word is transmitted while another is being converted. A data conversion cycle is initiated when a remote data acquisition card receives the proper command and address from the controller.

  13. A microcomputer based data acquisition system and experiment controller

    NASA Technical Reports Server (NTRS)

    Ganz, M. W.

    1981-01-01

    A data acquisition system is described. The system monitors and records the signal strength of a radio beacon sent to Earth from a geosynchronous satellite. It acquires data from several devices such as a radar, a radiometer, and a rain gauge which monitor the meteorological conditions along the Earth space propagation path. The acquired data are stored in digital format on magnetic tape for analysis at the computer center. A detailed description of the design and operation of the system's various hardware components is given. Schematic diagrams, the theory of operation, and normal operating procedures are presented.

  14. LASL-ORNL fast digital data acquisition system

    SciTech Connect

    Hendricks, R.W.; Seeger, P.A.; Scheer, J.W.; Suehiro, S.

    1980-06-01

    A data acquisition system for recording multi-parameter digital data into a large memory array at 1 MHz is described. The system consists of a MOSTEK MK8600 2048K x 24-bit memory system, I/0 ports to various external devices including the CAMAC dataway, a memory incrementer and a daisy-chain of experiment-specific modules which calculate the memory address which is to be incremented. The design of the daisy-chain permits multiple modules and provides for easy modification as experimental needs change. Several specific examples are described.

  15. Fast data acquisition system for the spectrometer SMART at RIKEN

    NASA Astrophysics Data System (ADS)

    Okamura, H.

    2000-03-01

    A new data acquisition system has been introduced for experiments using the spectrometer SMART at RIKEN. It is about ten times as fast as the previous system based on the standard CAMAC (Ichihara et al., IEEE Trans. Nucl. Sci. 36 (1989) 1628), but is dedicated to the use of LeCroy FERA and FERA-compatible modules. Data are accumulated in a VME memory module through the FERA bus and then DMA-transferred to a personal computer running a free Unix-clone, Linux. Since no CPU or peripheral is required on VME, the system is very cost-effective and suitable for experiments already using FERA.

  16. Advanced Self-Calibrating, Self-Repairing Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Medelius, Pedro J. (Inventor); Eckhoff, Anthony J. (Inventor); Angel, Lucena R. (Inventor); Perotti, Jose M. (Inventor)

    2002-01-01

    An improved self-calibrating and self-repairing Data Acquisition System (DAS) for use in inaccessible areas, such as onboard spacecraft, and capable of autonomously performing required system health checks, failure detection. When required, self-repair is implemented utilizing a "spare parts/tool box" system. The available number of spare components primarily depends upon each component's predicted reliability which may be determined using Mean Time Between Failures (MTBF) analysis. Failing or degrading components are electronically removed and disabled to reduce power consumption, before being electronically replaced with spare components.

  17. Modifying the Crystal Ball and Developing Data Acquisition Software

    NASA Astrophysics Data System (ADS)

    Strakovsky, Alexey; Oussena, Baya

    2010-11-01

    This poster describes work done with the A2 Collaboration at the Johannes Gutenberg Universitaet (JGU) in Mainz, Germany. In 2009, we modified the cabling of the Crystal Ball detector, housed at the Mainzer Mikrotron facility (MAMI) at JGU. This reduced the length of the 672 signal cables by approximately 43.68 km to reduce weight on the frame of the detector and make room for a frozen-spin hydrogen target. This involved cutting cables in half and resoldering the ends to new interface cards and photomultiplier tube connectors. More recently in 2010, our focus has been to develop new data acquisition software to replace the one currently in use. The new version, AcquDAQ, is based on C++ rather than the old C programming language. When completed, AcquDAQ will control and read data from the new electronics hardware utilized at MAMI, including the Crystal Ball.

  18. Data Acquisition and Image Reconstruction Systems from the miniPET Scanners to the CARDIOTOM Camera

    SciTech Connect

    Valastvan, I.; Imrek, J.; Hegyesi, G.; Molnar, J.; Novak, D.; Bone, D.; Kerek, A.

    2007-11-26

    Nuclear imaging devices play an important role in medical diagnosis as well as drug research. The first and second generation data acquisition systems and the image reconstruction library developed provide a unified hardware and software platform for the miniPET-I, miniPET-II small animal PET scanners and for the CARDIOTOM{sup TM}.

  19. PC-based Data Acquisition System for X-ray Crystal Spectrometer

    NASA Astrophysics Data System (ADS)

    Nam, U. W.; Kong, K. N.; Park, Y. S.; Kim, Y. J.; Lee, S. G.; Bak, J. G.; Bitter, M.; Hill, K.; Moon, M. K.; Cheon, J. K.; Lee, C. H.

    2003-10-01

    A PC-based data acquisition system for an X-ray crystal spectrometer has been developed in order to measure the ion and electron temperature profile measurements on tokamak plasmas. The system can detect a 2D image of the plasma from a gas-filled delay line readout position-sensitive 2D detector and spherically-bent crystal in connection with N110 time to digital converter developed in European Synchrotron Radiation Facility. The N110 interface module with TMS320VC33 digital signal processor, and 16 Mbytes static memory and its supporting Windows OS image software are used for the PC-based data acquisition system. An USB (Universal Serial Bus) interface of the PC was used to get image data from the system with higher than 10 Mbytes/s throughput rate because of its simplicity and high-speed communication capability. The system has two acquisition modes - a static and dynamic modes - which can build 256 x 256, 512 x 512, 1024 x 1024 and 2048 x2048 image frames. The dynamic mode is designed to obtain and store the position and time information of each photon events simultaneously with the maximum count-rate capability up to 500 kHz. An overview and demonstration of the PC-based data acquisition system will be presented.

  20. Design of area array CCD image acquisition and display system based on FPGA

    NASA Astrophysics Data System (ADS)

    Li, Lei; Zhang, Ning; Li, Tianting; Pan, Yue; Dai, Yuming

    2014-09-01

    With the development of science and technology, CCD(Charge-coupled Device) has been widely applied in various fields and plays an important role in the modern sensing system, therefore researching a real-time image acquisition and display plan based on CCD device has great significance. This paper introduces an image data acquisition and display system of area array CCD based on FPGA. Several key technical challenges and problems of the system have also been analyzed and followed solutions put forward .The FPGA works as the core processing unit in the system that controls the integral time sequence .The ICX285AL area array CCD image sensor produced by SONY Corporation has been used in the system. The FPGA works to complete the driver of the area array CCD, then analog front end (AFE) processes the signal of the CCD image, including amplification, filtering, noise elimination, CDS correlation double sampling, etc. AD9945 produced by ADI Corporation to convert analog signal to digital signal. Developed Camera Link high-speed data transmission circuit, and completed the PC-end software design of the image acquisition, and realized the real-time display of images. The result through practical testing indicates that the system in the image acquisition and control is stable and reliable, and the indicators meet the actual project requirements.

  1. Implementation of a versatile research data acquisition system using a commercially available medical ultrasound scanner.

    PubMed

    Hemmsen, Martin Christian; Nikolov, Svetoslav Ivanov; Pedersen, Mads Møller; Pihl, Michael Johannes; Enevoldsen, Marie Sand; Hansen, Jens Munk; Jensen, Jørgen Arendt

    2012-07-01

    This paper describes the design and implementation of a versatile, open-architecture research data acquisition system using a commercially available medical ultrasound scanner. The open architecture will allow researchers and clinicians to rapidly develop applications and move them relatively easy to the clinic. The system consists of a standard PC equipped with a camera link and an ultrasound scanner equipped with a research interface. The ultrasound scanner is an easy-to-use imaging device that is capable of generating high-quality images. In addition to supporting the acquisition of multiple data types, such as B-mode, M-mode, pulsed Doppler, and color flow imaging, the machine provides users with full control over imaging parameters such as transmit level, excitation waveform, beam angle, and focal depth. Beamformed RF data can be acquired from regions of interest throughout the image plane and stored to a file with a simple button press. For clinical trials and investigational purposes, when an identical image plane is desired for both an experimental and a reference data set, interleaved data can be captured. This form of data acquisition allows switching between multiple setups while maintaining identical transducer, scanner, region of interest, and recording time. Data acquisition is controlled through a graphical user interface running on the PC. This program implements an interface for third-party software to interact with the application. A software development toolkit is developed to give researchers and clinicians the ability to utilize third-party software for data analysis and flexible manipulation of control parameters. Because of the advantages of speed of acquisition and clinical benefit, research projects have successfully used the system to test and implement their customized solutions for different applications. Three examples of system use are presented in this paper: evaluation of synthetic aperture sequential beamformation, transverse

  2. Study of tracking and data acquisition system for the 1990's. Volume 4: TDAS space segment architecture

    NASA Technical Reports Server (NTRS)

    Orr, R. S.

    1984-01-01

    Tracking and data acquisition system (TDAS) requirements, TDAS architectural goals, enhanced TDAS subsystems, constellation and networking options, TDAS spacecraft options, crosslink implementation, baseline TDAS space segment architecture, and treat model development/security analysis are addressed.

  3. Caregivers' Suffix Frequencies and Suffix Acquisition by Language Impaired, Late Talking, and Typically Developing Children

    ERIC Educational Resources Information Center

    Warlaumont, Anne S.; Jarmulowicz, Linda

    2012-01-01

    Acquisition of regular inflectional suffixes is an integral part of grammatical development in English and delayed acquisition of certain inflectional suffixes is a hallmark of language impairment. We investigate the relationship between input frequency and grammatical suffix acquisition, analyzing 217 transcripts of mother-child (ages 1 ; 11-6 ;…

  4. Low-power triggered data acquisition system and method

    NASA Technical Reports Server (NTRS)

    Champaigne, Kevin (Inventor); Sumners, Jonathan (Inventor)

    2012-01-01

    A low-power triggered data acquisition system and method utilizes low-powered circuitry, comparators, and digital logic incorporated into a miniaturized device interfaced with self-generating transducer sensor inputs to detect, identify and assess impact and damage to surfaces and structures wherein, upon the occurrence of a triggering event that produces a signal greater than a set threshold changes the comparator output and causes the system to acquire and store digital data representative of the incoming waveform on at least one triggered channel. The sensors may be disposed in an array to provide triangulation and location of the impact.

  5. Wearable System for Acquisition and Monitoring of Biological Signals

    NASA Astrophysics Data System (ADS)

    Piccinini, D. J.; Andino, N. B.; Ponce, S. D.; Roberti, MA; López, y. N.

    2016-04-01

    This paper presents a modular, wearable system for acquisition and wireless transmission of biological signals. Configurable slaves for different signals (such as ECG, EMG, inertial sensors, and temperature) based in the ADS1294 Medical Analog Front End are connected to a Master, based in the CC3200 microcontroller, both from Texas Instruments. The slaves are configurable according to the specific application, providing versatility to the wearable system. The battery consumption is reduced, through a couple of Li-ion batteries and the circuit has also a battery charger. A custom made box was designed and fabricated in a 3D printer, preserving the requirements of low cost, low weight and safety recommendations.

  6. Acquisition system testing with superfluid helium. [cryopumping for space

    NASA Technical Reports Server (NTRS)

    Anderson, John E.; Fester, Dale A.; Dipirro, Michael J.

    1988-01-01

    Minus one-g outflow tests were conducted with superfluid helium in conjunction with a thermomechanical pump setup in order to study the use of capillary acquisition systems for NASA's Superfluid Helium On-Orbit Transfer (SHOOT) flight experiment. Results show that both fine mesh screen and porous sponge systems are capable of supplying superfluid helium to the thermomechanical pump inlet against a one-g head up to 4 cm, fulfilling the SHOOT requirements. Sponge results were found to be reproducible, while the screen results were not.

  7. Timing accuracy of the GEO 600 data acquisition system

    NASA Astrophysics Data System (ADS)

    Kötter, K.; Hewitson, M.; Ward, H.

    2004-03-01

    This paper describes the tests done for validating the timing accuracy of the GEO 600 data acquisition system. Correct time stamping of the recorded data is required for a number of search algorithms for gravitational wave signals (coincidence analysis, targeted pulsar searches, etc). Tests on the current system determined the absolute timing offset to be 15.89 µs with a standard deviation of 63 ns. Both offset and jitter were measured against an external reference clock. Additional analysis of data recorded during the S1 data taking run was done to validate the timing accuracy during this period.

  8. The Tara control, monitoring, data acquisition and analysis system

    SciTech Connect

    Sullivan, J.D.; Gaudreau, M.P.J.; Blanter, B.; Fredian, T.W.; Irby, J.H.; Karcher, C.A.; Rameriz, R.; Sevillano, E.; Stillerman, J.; Thomas, P.

    1986-09-01

    Experiments at the MIT Tara Tandem Mirror utilize an integrated system for control, monitoring, data acquisition, physics analysis, and archiving. This system consists of two distinct parts with narrowly defined information interchange; one to provide automated control and real time monitoring of engineering functions and one to acquire, analyze, and display data for physics in near real time. Typical machine operation achieves a total cycle time of 3 to 8 minutes with 5 to 7 Mbytes of data stored and with approx.160 individual signals displayed in hardcopy on approx.10 pages.

  9. Effect of transient liquid flow on retention characteristics of screen acquisition systems. [design of Space Shuttle feed system

    NASA Technical Reports Server (NTRS)

    Cady, E. C.

    1977-01-01

    A design analysis, is developed based on experimental data, to predict the effects of transient flow and pressure surges (caused either by valve or pump operation, or by boiling of liquids in warm lines) on the retention performance of screen acquisition systems. A survey of screen liquid acquisition system applications was performed to determine appropriate system environment and classification. A screen model was developed which assumed that the screen device was a uniformly distributed composite orthotropic structure, and which accounted for liquid inflow/outflow, gas ingestion quality, screen stress, and liquid spill. A series of 177 tests using 13 specimens (5 screen meshes, 4 screen device construction/backup methods, and 2 orientations) with three test fluids (isopropyl alcohol, Freon 114, and LH2) provided data which verified important features of the screen model and resulted in a design tool which could accurately predict the transient startup performance acquisition devices.

  10. System design description for mini-dacs data acquisition and control system

    SciTech Connect

    Vargo, F.G. Jr.; Trujillo, L.T.; Smith, S.O.

    1994-09-30

    This document describes the hardware computer system, for the mini data acquisition and control system (DACS) that was fabricated by Los Alamos National Laboratory (LANL), to support the testing of the spare mixer pump for SY-101.

  11. Nonredundant Roles of Iron Acquisition Systems in Vibrio cholerae

    PubMed Central

    Peng, Eric D.; Wyckoff, Elizabeth E.; Mey, Alexandra R.; Fisher, Carolyn R.

    2015-01-01

    Vibrio cholerae, the causative agent of the severe diarrheal disease cholera, thrives in both marine environments and the human host. To do so, it must encode the tools necessary to acquire essential nutrients, including iron, under these vastly different conditions. A number of V. cholerae iron acquisition systems have been identified; however, the precise role of each system is not fully understood. To test the roles of individual systems, we generated a series of mutants in which only one of the four systems that support iron acquisition on unsupplemented LB agar, Feo, Fbp, Vct, and Vib, remains functional. Analysis of these mutants under different growth conditions showed that these systems are not redundant. The strain carrying only the ferrous iron transporter Feo grew well at acidic, but not alkaline, pH, whereas the ferric iron transporter Fbp promoted better growth at alkaline than at acidic pH. A strain defective in all four systems (null mutant) had a severe growth defect under aerobic conditions but accumulated iron and grew as well as the wild type in the absence of oxygen, suggesting the presence of an additional, unidentified iron transporter in V. cholerae. In support of this, the null mutant was only moderately attenuated in an infant mouse model of infection. While the null mutant used heme as an iron source in vitro, we demonstrate that heme is not available to V. cholerae in the infant mouse intestine. PMID:26644383

  12. 48 CFR 34.004 - Acquisition strategy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the...

  13. 48 CFR 434.004 - Acquisition strategy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Acquisition strategy. 434... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 434.004 Acquisition strategy. (a) The program manager will develop, in coordination with the Acquisition Executive or Major Information...

  14. 48 CFR 34.004 - Acquisition strategy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the...

  15. 48 CFR 34.004 - Acquisition strategy.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the...

  16. 48 CFR 34.004 - Acquisition strategy.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the...

  17. 48 CFR 34.004 - Acquisition strategy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Acquisition strategy. 34... CATEGORIES OF CONTRACTING MAJOR SYSTEM ACQUISITION General 34.004 Acquisition strategy. The program manager, as specified in agency procedures, shall develop an acquisition strategy tailored to the...

  18. System control and data acquisition of the two new FWCD RF systems at DIII-D

    SciTech Connect

    Harris, T.E.; Allen, J.C.; Cary, W.P.; Petty, C.C.; Pinsker, R.I.; Ferguson, S.W.

    1995-12-31

    The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the transmitters utilizes VXI technology to communicate with the transmitter`s digital interface. A GPIB network allows for communication with various instruments and CAMAC crate controllers. CAMAC crates are located at each phase-shifter/stub-tuner station and are used to digitize transmission line parameters along with transmission line fault detection during RF transmission. The phase-shifter/stub-tuner stations are located throughout the DIII-D facility and are controlled from the FWCD operator console via the workstation`s Serial port. The Sun workstation has an Ethernet connection allowing for the utilization of the DIII-D data acquisition Open System architecture and of course providing communication with the rest of the world.

  19. System control and data acquisition of the two new FWCD RF systems at DIII-D

    SciTech Connect

    Harris, T.E.; Allen, J.C.; Cary, W.P. Petty, C.C.

    1995-10-01

    The Fast Wave Current Drive (FWCD) system at DIII-D has increased its available radio frequency (RF) power capabilities with the addition of two new high power transmitters along with their associated transmission line systems. A Sun Sparc-10 workstation, functioning as the FWCD operator console, is being used to control transmitter operating parameters and transmission line tuning parameters, along with acquiring data and making data available for integration into the DIII-D data acquisition system. Labview, a graphical user interface application, is used to manage and control the above processes. This paper will discuss the three primary branches of the FWCD computer control system: transmitter control, transmission line tuning control, and FWCD data acquisition. The main control program developed uses VXI, GPIB, CAMAC, Serial, and Ethernet protocols to blend the three branches together into one cohesive system. The control of the transmitters utilizes VXI technology to communicate with the transmitter`s digital interface. A GPIB network allows for communication with various instruments and CAMAC crate controllers. CAMAC crates are located at each phase-shifter/stub-tuner station and are used to digitize transmission line parameters along with transmission line fault detection during RF transmission. The phase-shifter/stub-tuner stations are located through out the DIII-D facility and are controlled from the FWCD operator console via the workstation`s Serial port. The Sun workstation has an Ethernet connection allowing for the utilization of the DIII-D data acquisition {open_quotes}Open System{close_quotes} architecture and of course providing communication with the rest of the world.

  20. Low cost open data acquisition system for biomedical applications

    NASA Astrophysics Data System (ADS)

    Zabolotny, Wojciech M.; Laniewski-Wollk, Przemyslaw; Zaworski, Wojciech

    2005-09-01

    In the biomedical applications it is often necessary to collect measurement data from different devices. It is relatively easy, if the devices are equipped with a MIB or Ethernet interface, however often they feature only the asynchronous serial link, and sometimes the measured values are available only as the analog signals. The system presented in the paper is a low cost alternative to commercially available data acquisition systems. The hardware and software architecture of the system is fully open, so it is possible to customize it for particular needs. The presented system offers various possibilities to connect it to the computer based data processing unit - e.g. using the USB or Ethernet ports. Both interfaces allow also to use many such systems in parallel to increase amount of serial and analog inputs. The open source software used in the system makes possible to process the acquired data with standard tools like MATLAB, Scilab or Octave, or with a dedicated, user supplied application.

  1. The research of data acquisition system for Raman spectrometer

    NASA Astrophysics Data System (ADS)

    Cui, Xiao; Guo, Pan; Zhang, Yinchao; Chen, Siying; Chen, He; Chen, Wenbo

    2011-11-01

    Raman spectrometer has been widely used as an identification tool for analyzing material structure and composition in many fields. However, Raman scattering echo signal is very weak, about dozens of photons at most in one laser plus signal. Therefore, it is a great challenge to design a Raman spectrum data acquisition system which could accurately receive the weak echo signal. The system designed in this paper receives optical signals with the principle of photon counter and could detect single photon. The whole system consists of a photoelectric conversion module H7421-40 and a photo counting card including a field programmable gate array (FPGA) chip and a PCI9054 chip. The module H7421-40 including a PMT, an amplifier and a discriminator has high sensitivity on wavelength from 300nm to 720nm. The Center Wavelength is 580nm which is close to the excitation wavelength (532nm), QE 40% at peak wavelength, Count Sensitivity is 7.8*105(S-1PW-1) and Count Linearity is 1.5MHZ. In FPGA chip, the functions are divided into three parts: parameter setting module, controlling module, data collection and storage module. All the commands, parameters and data are transmitted between FPGA and computer by PCI9054 chip through the PCI interface. The result of experiment shows that the Raman spectrum data acquisition system is reasonable and efficient. There are three primary advantages of the data acquisition system: the first one is the high sensitivity with single photon detection capability; the second one is the high integrated level which means all the operation could be done by the photo counting card; and the last one is the high expansion ability because of the smart reconfigurability of FPGA chip.

  2. High Speed Data Acquisition System for Three-Dimensional X-Ray and Neutron Computed Tomography

    SciTech Connect

    Davis, A.W.; Claytor, T.N.; Sheats, M.J.

    1999-07-01

    Computed tomography for nondestructive evaluation applications has been limited by system cost, resolution, and time requirements for three-dimensional data sets. FlashCT (Flat panel Amorphous Silicon High-Resolution Computed Tomography) is a system developed at Los Alamos National Laboratory to address these three problems. Developed around a flat panel amorphous silicon detector array, FlashCT is suitable for low to medium energy x-ray and neutron computed tomography at 127-micron resolution. Overall system size is small, allowing rapid transportation to a variety of radiographic sources. System control software was developed in LabVIEW for Windows NT to allow multithreading of data acquisition, data correction, and staging motor control. The system control software simplifies data collection and allows fully automated control of the data acquisition process, leading toward remote or unattended operation. The first generation of the FlashCT Data Acquisition System was completed in Au gust 1998, and since that time the system has been tested using x-ray sources ranging in energy from 60 kV to 20MV. The system has also been used to collect data for thermal neutron computed tomography at Los Alamos Neutron Science Center (LANSCE). System improvements have been proposed to provide faster data collection and greater dynamic range during data collection.

  3. A versatile data acquisition system and the ISOL facility TRISTAN

    NASA Astrophysics Data System (ADS)

    Gill, R. L.; Stelts, M. L.; Chrien, R. E.; Manzella, V.; Liou, H.; Shostak, S.

    The on-line mass separator, TRISTAN, is located at Brookhaven's High Flux Beam Reactor. A Nielsen-type ion source, which can contain up to 8g of 235U in an external beam with a flux of ˜2 × 10 9n/cm 2/s is used to generate short-lived fission products. Experiments have been constructed on two of the five available beam lines to measure β-γ and γ-γ coincidences, γ-γ angular correlations and delayed neutron emissions. A Users Group has been formed to coordinate research between University groups and BNL. Developments planned for TRISTAN include FEBIAD, surface ionization and negative-surface ionization-type ion sources, and a He-jet system as well as construction of new experimental facilities. An off-line separator, ISTU, is available for the development program. We have constructed a versatile, modular data acquisition system to service experiments on TRISTAN and other nuclear research facilities at the HFBR using CAMAC interfacing. Standard, commercially-available electronic instruments and computer programs, such as FORTRAN and system routines, are used throughout. Simple interfaces have been built to adapt non-CAMAC equipment to CAMAC input registers. Up to eight different experiments can be multiplexed on the branch highway by a fast microprogrammed branch driver with a 4096 word memory. The branch driver delivers pre-processed data to a bus which links devices such as a central processor, 1 megaword core memory, tape drives, discs, display processor and terminal. The following features are offered: two 8192 channel pulse height analyzers, a 3-parameter coincidence unit, 4 multiscalers, a timed sequence of delayed γ-ray spectra (33 spectra of 4096 channels each), a 2-parameter (pulse height versus time-of-flight) analyzer, 16 scalers and 24 experimental interlocks. Up to 100 different spectra are available to users for display during an experiment. Event mode recording on magnetic tape and direct sorting into the 1 megaword array are used as

  4. Spent fuel test. Climax data acquisition system integration report

    SciTech Connect

    Nyholm, R.A.; Brough, W.G.; Rector, N.L.

    1982-06-01

    The Spent Fuel Test - Climax (SFT-C) is a test of the retrievable, deep geologic storage of commercially generated, spent nuclear reactor fuel in granitic rock. Eleven spent fuel assemblies, together with 6 electrical simulators and 20 guard heaters, are emplaced 420 m below the surface in the Climax granite at the Nevada Test Site. On June 2, 1978, Lawrence Livermore National Laboratory (LLNL) secured funding for the SFT-C, and completed spent fuel emplacement May 28, 1980. This multi-year duration test is located in a remote area and is unattended much of the time. An extensive array of radiological safety and geotechnical instrumentation is deployed to monitor the test performance. A dual minicomputer-based data acquisition system collects and processes data from more than 900 analog instruments. This report documents the design and functions of the hardware and software elements of the Data Acquisition System and describes the supporting facilities which include environmental enclosures, heating/air-conditioning/humidity systems, power distribution systems, fire suppression systems, remote terminal stations, telephone/modem communications, and workshop areas. 9 figures.

  5. The LUX experiment - trigger and data acquisition systems

    NASA Astrophysics Data System (ADS)

    Druszkiewicz, Eryk

    2013-04-01

    The Large Underground Xenon (LUX) detector is a two-phase xenon time projection chamber designed to detect interactions of dark matter particles with the xenon nuclei. Signals from the detector PMTs are processed by custom-built analog electronics which provide properly shaped signals for the trigger and data acquisition (DAQ) systems. During calibrations, both systems must be able to handle high rates and have large dynamic ranges; during dark matter searches, maximum sensitivity requires low thresholds. The trigger system uses eight-channel 64-MHz digitizers (DDC-8) connected to a Trigger Builder (TB). The FPGA cores on the digitizers perform real-time pulse identification (discriminating between S1 and S2-like signals) and event localization. The TB uses hit patterns, hit maps, and maximum response detection to make trigger decisions, which are reached within few microseconds after the occurrence of an event of interest. The DAQ system is comprised of commercial digitizers with customized firmware. Its real-time baseline suppression allows for a maximum event acquisition rate in excess of 1.5 kHz, which results in virtually no deadtime. The performance of the trigger and DAQ systems during the commissioning runs of LUX will be discussed.

  6. Colorized linear CCD data acquisition system with automatic exposure control

    NASA Astrophysics Data System (ADS)

    Li, Xiaofan; Sui, Xiubao

    2014-11-01

    Colorized linear cameras deliver superb color fidelity at the fastest line rates in the industrial inspection. It's RGB trilinear sensor eliminates image artifacts by placing a separate row of pixels for each color on a single sensor. It's advanced design minimizes distance between rows to minimize image artifacts due to synchronization. In this paper, the high-speed colorized linear CCD data acquisition system was designed take advantages of the linear CCD sensor μpd3728. The hardware and software design of the system based on FPGA is introduced and the design of the functional modules is performed. The all system is composed of CCD driver module, data buffering module, data processing module and computer interface module. The image data was transferred to computer by Camera link interface. The system which automatically adjusts the exposure time of linear CCD, is realized with a new method. The integral time of CCD can be controlled by the program. The method can automatically adjust the integration time for different illumination intensity under controlling of FPGA, and respond quickly to brightness changes. The data acquisition system is also offering programmable gains and offsets for each color. The quality of image can be improved after calibration in FPGA. The design has high expansibility and application value. It can be used in many application situations.

  7. The Data Acquisition System for the BGOegg experiment

    NASA Astrophysics Data System (ADS)

    Mizutani, Keigo; Ishikawa, Takatsugu; Hamano, Hirotomo; Miyabe, Manabu; Yamazaki, Ryuji; Masumoto, Shinichi; Tsuchikawa, Yusuke; Muramatsu, Norihito; LEPS2/BGOegg Collaboration

    2014-09-01

    The BGOegg experiment has started in December 2013 at SPring-8/LEPS2 facility. The aim of the experiment is to study hadron properties via photo-production using high-intensity and linear-polarized photon beam generated by backward Compton scattering with 8-GeV electrons in SPring-8 and photons from external lasers. The event rate of this experiment is expected to be about 1 kHz. In order to take data with the efficiency over 90% for 1 kHz trigger rate, we have constructed the data acquisition system mainly consisting of FERA-UIO and VME-TDC subsystems. The BGOegg detector system consists of a beam tagging counter, the BGOegg electromagnetic calorimeter, a cylindrical drift chamber, inner plastic scintillators, a forward drift chamber, and forward TOF-RPCs. The tagging counter and the BGOegg participate in the trigger. The number of readout channels is over 2500 in total. For the readout of these detectors with short dead time, we use 16 collector VME CPUs distributed over TCP/IP networks. We will present details and the performance of the BGOegg data acquisition system. The BGOegg experiment has started in December 2013 at SPring-8/LEPS2 facility. The aim of the experiment is to study hadron properties via photo-production using high-intensity and linear-polarized photon beam generated by backward Compton scattering with 8-GeV electrons in SPring-8 and photons from external lasers. The event rate of this experiment is expected to be about 1 kHz. In order to take data with the efficiency over 90% for 1 kHz trigger rate, we have constructed the data acquisition system mainly consisting of FERA-UIO and VME-TDC subsystems. The BGOegg detector system consists of a beam tagging counter, the BGOegg electromagnetic calorimeter, a cylindrical drift chamber, inner plastic scintillators, a forward drift chamber, and forward TOF-RPCs. The tagging counter and the BGOegg participate in the trigger. The number of readout channels is over 2500 in total. For the readout of these

  8. Magnetic-Field-Response Measurement-Acquisition System

    NASA Technical Reports Server (NTRS)

    Woodward, Stanley E.; Shams, Qamar A.; Fox, Robert L.; Taylor, Bryant D.

    2006-01-01

    A measurement-acquisition system uses magnetic fields to power sensors and to acquire measurements from sensors. The system alleviates many shortcomings of traditional measurement-acquisition systems, which include a finite number of measurement channels, weight penalty associated with wires, use limited to a single type of measurement, wire degradation due to wear or chemical decay, and the logistics needed to add new sensors. Eliminating wiring for acquiring measurements can alleviate potential hazards associated with wires, such as damaged wires becoming ignition sources due to arcing. The sensors are designed as electrically passive inductive-capacitive or passive inductive-capacitive-resistive circuits that produce magnetic-field-responses. One or more electrical parameters (inductance, capacitance, and resistance) of each sensor can be variable and corresponds to a measured physical state of interest. The magnetic-field- response attributes (frequency, amplitude, and bandwidth) of the inductor correspond to the states of physical properties for which each sensor measures. For each sensor, the measurement-acquisition system produces a series of increasing magnetic-field harmonics within a frequency range dedicated to that sensor. For each harmonic, an antenna electrically coupled to an oscillating current (the frequency of which is that of the harmonic) produces an oscillating magnetic field. Faraday induction via the harmonic magnetic fields produces an electromotive force and therefore a current in the sensor. Once electrically active, the sensor produces its own harmonic magnetic field as the inductor stores and releases magnetic energy. The antenna of the measurement- acquisition system is switched from a transmitting to a receiving mode to acquire the magnetic-field response of the sensor. The rectified amplitude of the received response is compared to previous responses to prior transmitted harmonics, to ascertain if the measurement system has detected a

  9. VETA x ray data acquisition and control system

    NASA Technical Reports Server (NTRS)

    Brissenden, R. J. V.; Jones, M. T.; Ljungberg, M.; Nguyen, D. T.; Roll, J. B., Jr.

    1992-01-01

    We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the x-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of x-ray data were acquired, analyzed, and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping, and proportional counter window uniformity data. The system architecture will be presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity, and system extensibility. The VETA test data archive are also described.

  10. VETA X-ray Data Acquisition and Control System

    NASA Technical Reports Server (NTRS)

    Brissenden, Roger J. V.; Jones, Mark T.; Ljungberg, Malin; Nguyen, Dan T.; Roll, John B., Jr.

    1993-01-01

    We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

  11. VETA x ray data acquisition and control system

    NASA Technical Reports Server (NTRS)

    Brissenden, Roger J. V.; Jones, Mark T.; Ljungberg, Malin; Nguyen, Dan T.; Roll, John B., Jr.

    1992-01-01

    We describe the X-ray Data Acquisition and Control System (XDACS) used together with the X-ray Detection System (XDS) to characterize the X-ray image during testing of the AXAF P1/H1 mirror pair at the MSFC X-ray Calibration Facility. A variety of X-ray data were acquired, analyzed and archived during the testing including: mirror alignment, encircled energy, effective area, point spread function, system housekeeping and proportional counter window uniformity data. The system architecture is presented with emphasis placed on key features that include a layered UNIX tool approach, dedicated subsystem controllers, real-time X-window displays, flexibility in combining tools, network connectivity and system extensibility. The VETA test data archive is also described.

  12. Control and data acquisition systems for high field superconducting wigglers

    NASA Astrophysics Data System (ADS)

    Batrakov, A.; Ilyin, I.; Karpov, G.; Kozak, V.; Kuzin, M.; Kuper, E.; Mamkin, V.; Mezentsev, N.; Repkov, V.; Selivanov, A.; Shkaruba, V.

    2001-07-01

    This paper describes the control and DAQ system of superconducting wigglers with magnetic field range up to 10.3 T. The first version of the system controls a 7 T superconducting wiggler prepared for installation at Bessy-II (Germany). The second one controls a 10 T wiggler which is under testing now at the SPring-8 site (Japan). Both systems are based on VME apparatus. The set of specialized VME modules is elaborated to arrange wiggler power supply control, full time wiggler monitoring, and magnetic field high accuracy measurement and field stabilization. The software for the control of the wigglers is written in C language for VxWorks operation system for a Motorola-162 VME controller. The task initialization, stops and acquisition of the data can be done from the nearest personal computer (FTP host for VME), or from the remote system as well.

  13. Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

    SciTech Connect

    Alves de Oliveira, Juliano; Assis de Melo, Marco Antônio; Guazzelli da Silveira, Marcilei A.; Medina, Nilberto H.

    2014-11-11

    In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.

  14. Electronic system for data acquisition to study radiation effects on operating MOSFET transistors

    NASA Astrophysics Data System (ADS)

    de Oliveira, Juliano Alves; de Melo, Marco Antônio Assis; da Silveira, Marcilei A. Guazzelli; Medina, Nilberto H.

    2014-11-01

    In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.

  15. EWLMII: a measurement and data-acquisition system for radon daughters

    SciTech Connect

    Keefe, D.J.; McDowell, W.P.; Groer, P.G.

    1981-01-01

    Development of new methods and instruments for the measurement of WL and Rn-daughter concentrations has been in progress for several years. However, efficient methods of data acquisition has not been the primary thrust of this research. If large volumes of data from automated instruments are to be efficiently analyzed, a built in data acquisition system is needed. One such instrument, the EWLMII, is described. The need for accelerated research for the understanding and control of Rn-daughters can be enhanced by such an instrument.

  16. The collection and analysis of transient test data using the mobile instrumentation data acquisition system (MIDAS)

    SciTech Connect

    Uncapher, W.L.; Arviso, M.

    1995-12-31

    Packages designed to transport radioactive materials are required to survive exposure to environments defined in Code of Federal Regulations. Cask designers can investigate package designs through structural and thermal testing of full-scale packages, components, or representative models. The acquisition of reliable response data from instrumentation measurement devices is an essential part of this testing activity. Sandia National Laboratories, under the sponsorship of the US Department of Energy (DOE), has developed the Mobile Instrumentation Data Acquisition System (MIDAS) dedicated to the collection and processing of structural and thermal data from regulatory tests.

  17. Floating data acquisition system for microwave calorimeter measurements on MTX

    SciTech Connect

    Sewall, N.R.; Meassick, S. )

    1989-09-13

    A microwave calorimeter has been designed for making 140-GHz absorption measurements on the MTX. Measurement of the intensity and spatial distribution of the FEL-generated microwave beam on the inner wall will indicate the absorption characteristics of the plasma when heated with a 140 GHz FEL pulse. The calorimeter works by monitoring changes of temperature in silicon carbide tiles located on the inner wall of the tokamak. Thermistors are used to measure the temperature of each tile. The tiles are located inside the tokamak about 1 cm outside of the limiter radius at machine potential. The success of this measurement depends on our ability to float the data acquisition system near machine potential and isolate it from the rest of the vault ground system. Our data acquisition system has 48 channels of thermistor signal conditioning, a multiplexer and digitizer section, a serial data formatter, and a fiber-optic transmitter to send the data out. Additionally, we bring timing signals to the interface through optical fibers to tell it when to begin measurement, while maintaining isolation. The receiver is an HP 200 series computer with a serial data interface; the computer provides storage and local display for the shot temperature profile. Additionally, the computer provides temporary storage of the data until it can be passed to a shared resource management system for archiving. 2 refs., 6 figs.

  18. Data Acquisition and Processing System for Airborne Wind Profiling with a Pulsed, 2-Micron, Coherent-Detection, Doppler Lidar System

    NASA Technical Reports Server (NTRS)

    Beyon, J. Y.; Koch, G. J.; Kavaya, M. J.

    2010-01-01

    A data acquisition and signal processing system is being developed for a 2-micron airborne wind profiling coherent Doppler lidar system. This lidar, called the Doppler Aerosol Wind Lidar (DAWN), is based on a Ho:Tm:LuLiF laser transmitter and 15-cm diameter telescope. It is being packaged for flights onboard the NASA DC-8, with the first flights in the summer of 2010 in support of the NASA Genesis and Rapid Intensification Processes (GRIP) campaign for the study of hurricanes. The data acquisition and processing system is housed in a compact PCI chassis and consists of four components such as a digitizer, a digital signal processing (DSP) module, a video controller, and a serial port controller. The data acquisition and processing software (DAPS) is also being developed to control the system including real-time data analysis and display. The system detects an external 10 Hz trigger pulse and initiates the data acquisition and processing process, and displays selected wind profile parameters such as Doppler shift, power distribution, wind directions and velocities. Doppler shift created by aircraft motion is measured by an inertial navigation/GPS sensor and fed to the signal processing system for real-time removal of aircraft effects from wind measurements. A general overview of the system and the DAPS as well as the coherent Doppler lidar system is presented in this paper.

  19. Apercu de certains developpements recents des recherches sur l'acquisition du langage (Recent Developments in Language Acquisition Research)

    ERIC Educational Resources Information Center

    Berthoz-Proux, Michelle

    1975-01-01

    The goal of this article is to give a survey of the literature and theoretical trends relevant to language acquisition. Developments in the fields of psychology, psycholinguistics, sociology, sociolinguistics and in various interdisciplinary studies are discussed. (Text is in French.) (CLK)

  20. Tracking and data relay satellite system - NASA's new spacecraft data acquisition system

    NASA Technical Reports Server (NTRS)

    Schneider, W. C.; Garman, A. A.

    1979-01-01

    This paper describes NASA's new spacecraft acquisition system provided by the Tracking and Data Relay Satellite System (TDRSS). Four satellites in geostationary orbit and a ground terminal will provide complete tracking, telemetry, and command service for all of NASA's orbital satellites below a 12,000 km altitude. Western Union will lease the system, operate the ground terminal and provide operational satellite control. NASA's network control center will be the focal point for scheduling user services and controlling the interface between TDRSS and the NASA communications network, project control centers, and data processing. TDRSS single access user spacecraft data systems will be designed for time shared data relay support, and reimbursement policy and rate structure for non-NASA users are being developed.

  1. System Description for Tank 241-AZ-101 Waste Retrieval Data Acquisition System

    SciTech Connect

    ROMERO, S.G.

    2000-01-10

    Describes the hardware and software for the AZ-101 Mixer Pump Data Acquisition System. The purpose of the tank 241-AZ-101 retrieval system Data Acquisition System (DAS) is to provide monitoring and data acquisition of key parameters in order to confirm the effectiveness of the mixer pumps utilized for suspending solids in the tank. The suspension of solids in Tank 241-AZ-101 is necessary for pretreatment of the neutralized current acid waste (NCAW), and eventual disposal as glass via the Hanford Waste Vitrification Plant.

  2. WIND TURBINE DRIVETRAIN TEST FACILITY DATA ACQUISITION SYSTEM

    SciTech Connect

    Mcintosh, J.

    2012-01-03

    The Wind Turbine Drivetrain Test Facility (WTDTF) is a state-of-the-art industrial facility used for testing wind turbine drivetrains and generators. Large power output wind turbines are primarily installed for off-shore wind power generation. The facility includes two test bays: one to accommodate turbine nacelles up to 7.5 MW and one for nacelles up to 15 MW. For each test bay, an independent data acquisition system (DAS) records signals from various sensors required for turbine testing. These signals include resistance temperature devices, current and voltage sensors, bridge/strain gauge transducers, charge amplifiers, and accelerometers. Each WTDTF DAS also interfaces with the drivetrain load applicator control system, electrical grid monitoring system and vibration analysis system.

  3. The D0 level three data acquisition system

    SciTech Connect

    D. Chapin et al.

    2004-03-17

    The DZERO experiment located at Fermilab has recently started RunII with an upgraded detector. The RunII physics program requires the Data Acquisition to readout the detector at a rate of 1 KHz. Events fragments, totaling 250 KB, are readout from approximately 60 front end crates and sent to a particular farm node for Level 3 Trigger processing. A scalable system, capable of complex event routing, has been designed and implemented based on commodity components: VMIC 7750 Single Board Computers for readout, a Cisco 6509 switch for data flow, and close to 100 Linux-based PCs for high-level event filtering.

  4. Wind tunnel real-time data acquisition system

    NASA Technical Reports Server (NTRS)

    Cole, P.

    1979-01-01

    The hardware configuration is described for the data acquisition system (DAS) which consists of an analog front end that can process up to 260 channels of data, a multichannel analog-to-digital subsystem that can process up to 50,000 samples of data per second, and a digital computer with standard and nonstandard devices, including graphics capability. Also described are the software configuration of the DAS and complex hardware/software interfaces providing, for example, automatic amplifier gain and offset adjustment for each data channel. Specific DAS applications are summarized, including the real time processing of dynamic deflection data, unsteady pressure measurements, and flutter and buffet data.

  5. Data acquisition in a wireless diabetic and cardiac monitoring system.

    PubMed

    Harvey, Paul; Woodward, Bryan; Datta, Sekharjit; Mulvaney, David

    2011-01-01

    A telemedicine system is described for monitoring the vital signs and general health indicators of patients with cardiac and diabetic conditions. Telemetry from wireless sensors and readings from other instruments are combined into a comprehensive patient health dataset. The data can be stored, accessed and displayed using mobile Internet communications with a server. The paper concentrates on the data acquisition process, using an alternative sensor network protocol to Bluetooth and manual data entry into a smartphone application and HTML5 web browser. PMID:22255009

  6. Knowledge Acquisition, Validation, and Maintenance in a Planning System for Automated Image Processing

    NASA Technical Reports Server (NTRS)

    Chien, Steve A.

    1996-01-01

    A key obstacle hampering fielding of AI planning applications is the considerable expense of developing, verifying, updating, and maintainting the planning knowledge base (KB). Planning systems must be able to compare favorably in terms of software lifecycle costs to other means of automation such as scripts or rule-based expert systems. This paper describes a planning application of automated imaging processing and our overall approach to knowledge acquisition for this application.

  7. Research into the development of a knowledge acquisition taxonomy

    NASA Technical Reports Server (NTRS)

    Fink, Pamela K.

    1991-01-01

    Monthly progress reports for September 1990 to January 1991 are given. Topics that are briefly covered include problem solving and learning taxonomies, knowledge acquisition techniques, software design, air traffic control, and space shuttle flight control.

  8. 77 FR 39125 - Defense Acquisition Regulations System; Defense Federal Acquisition Regulation Supplement; Only...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-29

    ... at 76 FR 44293 on July 25, 2011, to address acquisitions using competitive procedures in which only..., 2011 (76 FR 59623) through October 7, 2011. DoD received comments on the proposed rule from...

  9. Real-time data acquisition and control system for the measurement of motor and neural data.

    PubMed

    Bryant, Christopher L; Gandhi, Neeraj J

    2005-03-30

    This paper outlines a powerful, yet flexible real-time data acquisition and control system for use in the triggering and measurement of both analog and digital events. Built using the LabVIEW development architecture (version 7.1) and freely available, this system provides precisely timed auditory and visual stimuli to a subject while recording analog data and timestamps of neural activity retrieved from a window discriminator. The system utilizes the most recent real-time (RT) technology in order to provide not only a guaranteed data acquisition rate of 1 kHz, but a much more difficult to achieve guaranteed system response time of 1 ms. The system interface is windows-based and easy to use, providing a host of configurable options for end-user customization. PMID:15698659

  10. Study of a Tracking and Data Acquisition System (TDAS) in the 1990's

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Progress in concept definition studies, operational assessments, and technology demonstrations for the Tracking and Data Acquisition System (TDAS) is reported. The proposed TDAS will be the follow-on to the Tracking and Data Relay Satellite System and will function as a key element of the NASA End-to-End Data System, providing the tracking and data acquisition interface between user accessible data ports on Earth and the user's spaceborne equipment. Technical activities of the "spacecraft data system architecture' task and the "communication mission model' task are emphasized. The objective of the first task is to provide technology forecasts for sensor data handling, navigation and communication systems, and estimate corresponding costs. The second task is concerned with developing a parametric description of the required communication channels. Other tasks with significant activity include the "frequency plan and radio interference model' and the "Viterbi decoder/simulator study'.

  11. New CAMAC based data acquisition and beam control system for Lund nuclear microprobe

    NASA Astrophysics Data System (ADS)

    Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Pallon, Jan; Sjöland, Anders; Utui, Rogerio; Yang, Changyi

    1997-07-01

    A new CAMAC based data acquisition system has been installed at the Lund Nuclear Microprobe facility. This paper reports on the development and present status of the data acquisition system. The system is a true multiparameter CAMAC based system with fast Fera bus readout and in crate memory buffer. The user interface is based on Sparrow Kmax software for a Power Macintosh platform. The system read out and tag the event data with position on-line, which make fast on-line monitoring of spectra or element maps possible.Simultaneously, all data can be saved event by event for off-line analysis. The beam scanning part is software controlled through a timed D/A converter, this allows fast scanning of the beam. With a CCD-camera and video card the area to be analysed could be defined directly from the image, and the sample position can be moved. Any kind of irregular scan patterns could be defined.

  12. Knowledge acquisition and representation for the Systems Test and Operations Language (STOL) Intelligent Tutoring System (ITS)

    NASA Technical Reports Server (NTRS)

    Seamster, Thomas L.; Eike, David R.; Ames, Troy J.

    1990-01-01

    This presentation concentrates on knowledge acquisition and its application to the development of an expert module and a user interface for an Intelligent Tutoring System (ITS). The Systems Test and Operations Language (STOL) ITS is being developed to assist NASA control center personnel in learning a command and control language as it is used in mission operations rooms. The objective of the tutor is to impart knowledge and skills that will permit the trainee to solve command and control problems in the same way that the STOL expert solves those problems. The STOL ITS will achieve this object by representing the solution space in such a way that the trainee can visualize the intermediate steps, and by having the expert module production rules parallel the STOL expert's knowledge structures.

  13. Data acquisition systems for the Sloan Digital Sky Survey

    SciTech Connect

    Petravick, D.; Berman, E.; MacKinnon, B.; Nicinski, T.; Pordes, R.; Sergey, G.; Rechenmacher, R.; Annis, J.; Kent, S.; McKay, T.; Stoughton, C.; Husby, D.

    1994-03-01

    The Sloan Digital Sky Survey (SDSS) will image {Pi} steradians about the north galactic cap in five filters, and acquire one million spectra using a dedicated 2.5 meter telescope at the Apache Point Observatory in New Mexico. The authors describe the data acquisition system for the survey`s three main detectors: an imaging camera, mounting 54 Tektronix charge-coupled devices (CCD); a pair of spectrographs, each mounting a pair of CCDs; and a smaller monitor telescope camera. The authors describe the system`s hardware and software architecture, and relate it to the survey`s special requirements for high reliability and need to understand its instrumentation in order to produce a consistent survey over a five year period.

  14. System and method for acquisition management of subject position information

    DOEpatents

    Carrender, Curt

    2007-01-23

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  15. System and method for acquisition management of subject position information

    DOEpatents

    Carrender, Curt

    2005-12-13

    A system and method for acquisition management of subject position information that utilizes radio frequency identification (RF ID) to store position information in position tags. Tag programmers receive position information from external positioning systems, such as the Global Positioning System (GPS), from manual inputs, such as keypads, or other tag programmers. The tag programmers program each position tag with the received position information. Both the tag programmers and the position tags can be portable or fixed. Implementations include portable tag programmers and fixed position tags for subject position guidance, and portable tag programmers for collection sample labeling. Other implementations include fixed tag programmers and portable position tags for subject route recordation. Position tags can contain other associated information such as destination address of an affixed subject for subject routing.

  16. Multispectral data acquisition and classification - Statistical models for system design

    NASA Technical Reports Server (NTRS)

    Huck, F. O.; Park, S. K.

    1978-01-01

    In this paper we relate the statistical processes that are involved in multispectral data acquisition and classification to a simple radiometric model of the earth surface and atmosphere. If generalized, these formulations could provide an analytical link between the steadily improving models of our environment and the performance characteristics of rapidly advancing device technology. This link is needed to bring system analysis tools to the task of optimizing remote sensing and (real-time) signal processing systems as a function of target and atmospheric properties, remote sensor spectral bands and system topology (e.g., image-plane processing), radiometric sensitivity and calibration accuracy, compensation for imaging conditions (e.g., atmospheric effects), and classification rates and errors.

  17. NASA activities and plans. [on satellite tracking, data acquisition, communication and mission control systems and capabilities

    NASA Technical Reports Server (NTRS)

    Smylie, R. E.

    1981-01-01

    An overview is provided of the NASA tracking, data acquisition, communications, and mission control systems and capabilities. These systems include the NASA Spaceflight Tracking and Data Network (STDN) which supports earth-orbital spacecraft, the Deep Space Network (DSN) which supports the planetary exploration and deep space missions, and the Tracking and Data Relay Satellite System (TDRSS) currently under development and scheduled to come into service in 1983. TDRSS will then displace STDN for support of low earth orbital spacecraft. A description is presented of the current status of the considered systems, and plans are discussed for future developments and new capabilities.

  18. Computer system design description for the spare pump mini-dacs data acquisition and control system

    SciTech Connect

    Vargo, G.F. Jr.

    1994-09-29

    The attached document outlines the computer software design for the mini data acquisition and control system (DACS), that supports the testing of the spare pump for Tank 241-SY-101, at the maintenance and storage facility (MASF).

  19. Integrated Component-based Data Acquisition Systems for Aerospace Test Facilities

    NASA Technical Reports Server (NTRS)

    Ross, Richard W.

    2001-01-01

    The Multi-Instrument Integrated Data Acquisition System (MIIDAS), developed by the NASA Langley Research Center, uses commercial off the shelf (COTS) products, integrated with custom software, to provide a broad range of capabilities at a low cost throughout the system s entire life cycle. MIIDAS combines data acquisition capabilities with online and post-test data reduction computations. COTS products lower purchase and maintenance costs by reducing the level of effort required to meet system requirements. Object-oriented methods are used to enhance modularity, encourage reusability, and to promote adaptability, reducing software development costs. Using only COTS products and custom software supported on multiple platforms reduces the cost of porting the system to other platforms. The post-test data reduction capabilities of MIIDAS have been installed at four aerospace testing facilities at NASA Langley Research Center. The systems installed at these facilities provide a common user interface, reducing the training time required for personnel that work across multiple facilities. The techniques employed by MIIDAS enable NASA to build a system with a lower initial purchase price and reduced sustaining maintenance costs. With MIIDAS, NASA has built a highly flexible next generation data acquisition and reduction system for aerospace test facilities that meets customer expectations.

  20. Dynamic high-speed acquisition system design of transmission error with USB based on LabVIEW and FPGA

    NASA Astrophysics Data System (ADS)

    Zheng, Yong; Chen, Yan

    2013-10-01

    To realize the design of dynamic acquisition system for real-time detection of transmission chain error is very important to improve the machining accuracy of machine tool. In this paper, the USB controller and FPGA is used for hardware platform design, combined with LabVIEW to design user applications, NI-VISA is taken for develop USB drivers, and ultimately achieve the dynamic acquisition system design of transmission error

  1. A first-generation software product line for data acquisition systems in astronomy

    NASA Astrophysics Data System (ADS)

    López-Ruiz, J. C.; Heradio, Rubén; Cerrada Somolinos, José Antonio; Coz Fernandez, José Ramón; López Ramos, Pablo

    2008-07-01

    This article presents a case study on developing a software product line for data acquisition systems in astronomy based on the Exemplar Driven Development methodology and the Exemplar Flexibilization Language tool. The main strategies to build the software product line are based on the domain commonality and variability, the incremental scope and the use of existing artifacts. It consists on a lean methodology with little impact on the organization, suitable for small projects, which reduces product line start-up time. Software Product Lines focuses on creating a family of products instead of individual products. This approach has spectacular benefits on reducing the time to market, maintaining the know-how, reducing the development costs and increasing the quality of new products. The maintenance of the products is also enhanced since all the data acquisition systems share the same product line architecture.

  2. Developing and implementing a data acquisition strategy for global agricultural monitoring: an inter-agency initiative

    NASA Astrophysics Data System (ADS)

    Justice, C. O.; Whitcraft, A. K.; Becker-Reshef, I.; Killough, B.

    2013-12-01

    In 2011, in response to global food crises, the G20 Agricultural Ministers launched a satellite-based global agricultural monitoring initiative to develop the Group on Earth Observations Global Agriculture Monitoring (GEOGLAM) system. The GEO is aimed at enhancing the availability and use of both satellite and in situ data for societal benefit. This initiative builds on the observation requirements developed by the GEO Agricultural Community of Practice, the understanding that no one satellite system can currently provide all the data needed for agricultural monitoring and the resulting recommendation for improved acquisition and availability of data by the World's space agencies. Implicit in this recommendation is the fact that certain regions of the Earth are imagery rich while others are imagery poor, leaving knowledge gaps about agricultural processes and food supply for certain areas of the World. In order to respond to these knowledge gaps and to strengthen national, regional, and global agricultural monitoring networks, GEOGLAM is working with the Committee on Earth Observations (CEOS), the space arm of GEO, to develop a coordinated global acquisition strategy. A key component of GEOGLAM is an effort to articulate the temporal and spatial Earth Observation (EO) requirements for monitoring; second, the identification of current and planned missions which are capable of fulfilling these EO requirements; and third, the development of a multi-agency, multi-mission image acquisition strategy for agricultural monitoring. CEOS engineers and GEOGLAM scientists have been collaborating on the EO requirements since 2012, and are now beginning the first implementation phase of the acquisition strategy. The goal is to put in place an operational system of systems using a virtual constellation of satellite-based sensors acquiring data to meet the needs for monitoring and early warning of shortfalls in agricultural production, a goal that was articulated in the 1970's

  3. Identification and Characterization of Cronobacter Iron Acquisition Systems

    PubMed Central

    Grim, C. J.; Kothary, M. H.; Gopinath, G.; Jarvis, K. G.; Beaubrun, J. Jean-Gilles; McClelland, M.; Tall, B. D.

    2012-01-01

    Cronobacter spp. are emerging pathogens that cause severe infantile meningitis, septicemia, or necrotizing enterocolitis. Contaminated powdered infant formula has been implicated as the source of Cronobacter spp. in most cases, but questions still remain regarding the natural habitat and virulence potential for each strain. The iron acquisition systems in 231 Cronobacter strains isolated from different sources were identified and characterized. All Cronobacter spp. have both the Feo and Efe systems for acquisition of ferrous iron, and all plasmid-harboring strains (98%) have the aerobactin-like siderophore, cronobactin, for transport of ferric iron. All Cronobacter spp. have the genes encoding an enterobactin-like siderophore, although it was not functional under the conditions tested. Furthermore, all Cronobacter spp. have genes encoding five receptors for heterologous siderophores. A ferric dicitrate transport system (fec system) is encoded specifically by a subset of Cronobacter sakazakii and C. malonaticus strains, of which a high percentage were isolated from clinical samples. Phylogenetic analysis confirmed that the fec system is most closely related to orthologous genes present in human-pathogenic bacterial strains. Moreover, all strains of C. dublinensis and C. muytjensii encode two receptors, FcuA and Fct, for heterologous siderophores produced by plant pathogens. Identification of putative Fur boxes and expression of the genes under iron-depleted conditions revealed which genes and operons are components of the Fur regulon. Taken together, these results support the proposition that C. sakazakii and C. malonaticus may be more associated with the human host and C. dublinensis and C. muytjensii with plants. PMID:22706064

  4. Identification and characterization of Cronobacter iron acquisition systems.

    PubMed

    Grim, C J; Kothary, M H; Gopinath, G; Jarvis, K G; Beaubrun, J Jean-Gilles; McClelland, M; Tall, B D; Franco, A A

    2012-09-01

    Cronobacter spp. are emerging pathogens that cause severe infantile meningitis, septicemia, or necrotizing enterocolitis. Contaminated powdered infant formula has been implicated as the source of Cronobacter spp. in most cases, but questions still remain regarding the natural habitat and virulence potential for each strain. The iron acquisition systems in 231 Cronobacter strains isolated from different sources were identified and characterized. All Cronobacter spp. have both the Feo and Efe systems for acquisition of ferrous iron, and all plasmid-harboring strains (98%) have the aerobactin-like siderophore, cronobactin, for transport of ferric iron. All Cronobacter spp. have the genes encoding an enterobactin-like siderophore, although it was not functional under the conditions tested. Furthermore, all Cronobacter spp. have genes encoding five receptors for heterologous siderophores. A ferric dicitrate transport system (fec system) is encoded specifically by a subset of Cronobacter sakazakii and C. malonaticus strains, of which a high percentage were isolated from clinical samples. Phylogenetic analysis confirmed that the fec system is most closely related to orthologous genes present in human-pathogenic bacterial strains. Moreover, all strains of C. dublinensis and C. muytjensii encode two receptors, FcuA and Fct, for heterologous siderophores produced by plant pathogens. Identification of putative Fur boxes and expression of the genes under iron-depleted conditions revealed which genes and operons are components of the Fur regulon. Taken together, these results support the proposition that C. sakazakii and C. malonaticus may be more associated with the human host and C. dublinensis and C. muytjensii with plants. PMID:22706064

  5. A Web-Remote/Robotic/Scheduled Astronomical Data Acquisition System

    NASA Astrophysics Data System (ADS)

    Denny, Robert

    2011-03-01

    Traditionally, remote/robotic observatory operating systems have been custom made for each observatory. While data reduction pipelines need to be tailored for each investigation, the data acquisition process (especially for stare-mode optical images) is often quite similar across investigations. Since 1999, DC-3 Dreams has focused on providing and supporting a remote/robotic observatory operating system which can be adapted to a wide variety of physical hardware and optics while achieving the highest practical observing efficiency and safe/secure web browser user controls. ACP Expert consists of three main subsystems: (1) a robotic list-driven data acquisition engine which controls all aspects of the observatory, (2) a constraint-driven dispatch scheduler with a long-term database of requests, and (3) a built-in "zero admin" web server and dynamic web pages which provide a remote capability for immediate execution and monitoring as well as entry and monitoring of dispatch-scheduled observing requests. No remote desktop login is necessary for observing, thus keeping the system safe and consistent. All routine operation is via the web browser. A wide variety of telescope mounts, CCD imagers, guiding sensors, filter selectors, focusers, instrument-package rotators, weather sensors, and dome control systems are supported via the ASCOM standardized device driver architecture. The system is most commonly employed on commercial 1-meter and smaller observatories used by universities and advanced amateurs for both science and art. One current project, the AAVSO Photometric All-Sky Survey (APASS), uses ACP Expert to acquire large volumes of data in dispatch-scheduled mode. In its first 18 months of operation (North then South), 40,307 sky images were acquired in 117 photometric nights, resulting in 12,107,135 stars detected two or more times. These stars had measures in 5 filters. The northern station covered 754 fields (6446 square degrees) at least twice, the southern

  6. Control and acquisition system for SWIR focal plane arrays from SOFRADIR

    NASA Astrophysics Data System (ADS)

    Beaufort, T.; Duvet, L.

    2009-07-01

    We report on the design, testing and characterization of a control and acquisition system developed for SWIR detectors from SOFRADIR. These detectors are MCT arrays developed for SWIR (Short Wavelength Infra Red) and hyperspectral applications;. The ROIC (Readout integrated circuitry) of each FPA (Focal Plane Array) delivers multiple analog outputs buffered and converted in the digital domain by dedicated board designed by SOFRADIR. These boards perform a time multiplexing of the digitized signals, leading to high data throughputs. Each FPA has its own dedicated Stirling micro-cooler. The control and acquisition system developed by our team is able to handle the high data throughput (up to 1.6 Gbit/s) thanks to a high speed acquisition board from National Instruments embedded in a PXI system. A standard DAQ card is used to acquire the house-keepings, control the different power supplies and clock generators while an SPI adapter enables the configuration of the FPA. The overall system is managed under the Labview environment with a flexible and comprehensive interface to the user with extensive logging of all operational parameters. The purpose of this paper is to describe the architecture of the overall system and to detail its performances.

  7. A low cost concept for data acquisition systems applied to decentralized renewable energy plants.

    PubMed

    Jucá, Sandro C S; Carvalho, Paulo C M; Brito, Fábio T

    2011-01-01

    The present paper describes experiences of the use of monitoring and data acquisition systems (DAS) and proposes a new concept of a low cost DAS applied to decentralized renewable energy (RE) plants with an USB interface. The use of such systems contributes to disseminate these plants, recognizing in real time local energy resources, monitoring energy conversion efficiency and sending information concerning failures. These aspects are important, mainly for developing countries, where decentralized power plants based on renewable sources are in some cases the best option for supplying electricity to rural areas. Nevertheless, the cost of commercial DAS is still a barrier for a greater dissemination of such systems in developing countries. The proposed USB based DAS presents a new dual clock operation philosophy, in which the acquisition system contains two clock sources for parallel information processing from different communication protocols. To ensure the low cost of the DAS and to promote the dissemination of this technology in developing countries, the proposed data acquisition firmware and the software for USB microcontrollers programming is a free and open source software, executable in the Linux and Windows® operating systems. PMID:22346600

  8. A Low Cost Concept for Data Acquisition Systems Applied to Decentralized Renewable Energy Plants

    PubMed Central

    Jucá, Sandro C. S.; Carvalho, Paulo C. M.; Brito, Fábio T.

    2011-01-01

    The present paper describes experiences of the use of monitoring and data acquisition systems (DAS) and proposes a new concept of a low cost DAS applied to decentralized renewable energy (RE) plants with an USB interface. The use of such systems contributes to disseminate these plants, recognizing in real time local energy resources, monitoring energy conversion efficiency and sending information concerning failures. These aspects are important, mainly for developing countries, where decentralized power plants based on renewable sources are in some cases the best option for supplying electricity to rural areas. Nevertheless, the cost of commercial DAS is still a barrier for a greater dissemination of such systems in developing countries. The proposed USB based DAS presents a new dual clock operation philosophy, in which the acquisition system contains two clock sources for parallel information processing from different communication protocols. To ensure the low cost of the DAS and to promote the dissemination of this technology in developing countries, the proposed data acquisition firmware and the software for USB microcontrollers programming is a free and open source software, executable in the Linux and Windows® operating systems. PMID:22346600

  9. Data acquisition/reduction system for flight testing general aviation aircraft

    NASA Technical Reports Server (NTRS)

    Rummer, D. I.; Mosser, M. A.; Renz, R. R. L.

    1982-01-01

    The development of a data acquisition/reduction system for use in the flight testing of general aviation aircraft is described. Design objectives for the system are adequate accuracy, ease of installation and removal from aircraft, simplicity of operation, and low cost. A 16-channel working system has been constructed, and tested in the collection of flight test data from a Cessna 172 aircraft, which uses as the basis of its design an AIM65 microcomputer. Data is reduced with a MINC minicomputer system. Attention is given to the onboard installation of computer, battery and transducer modules incorporated by the system.

  10. Position-Controlled Data Acquisition Embedded System for Magnetic NDE of Bridge Stay Cables

    PubMed Central

    Maldonado-Lopez, Rocio; Christen, Rouven

    2011-01-01

    This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ) system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges and the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented. PMID:22346572

  11. Position-controlled data acquisition embedded system for magnetic NDE of bridge stay cables.

    PubMed

    Maldonado-Lopez, Rocio; Christen, Rouven

    2011-01-01

    This work presents a custom-tailored sensing and data acquisition embedded system, designed to be integrated in a new magnetic NDE inspection device under development at Empa, a device intended for routine testing of large diameter bridge stay cables. The data acquisition (DAQ) system fulfills the speed and resolution requirements of the application and is able to continuously capture and store up to 2 GB of data at a sampling rate of 27 kS/s, with 12-bit resolution. This paper describes the DAQ system in detail, including both hardware and software implementation, as well as the key design challenges and the techniques employed to meet the specifications. Experimental results showing the performance of the system are also presented. PMID:22346572

  12. A direct-to-drive neural data acquisition system

    PubMed Central

    Kinney, Justin P.; Bernstein, Jacob G.; Meyer, Andrew J.; Barber, Jessica B.; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T.; Kopell, Nancy J.; Boyden, Edward S.

    2015-01-01

    Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future. PMID:26388740

  13. System of acquisition and processing of images of dynamic speckle

    NASA Astrophysics Data System (ADS)

    Vega, F.; >C Torres,

    2015-01-01

    In this paper we show the design and implementation of a system to capture and analysis of dynamic speckle. The device consists of a USB camera, an isolated system lights for imaging, a laser pointer 633 nm 10 mw as coherent light source, a diffuser and a laptop for processing video. The equipment enables the acquisition and storage of video, also calculated of different descriptors of statistical analysis (vector global accumulation of activity, activity matrix accumulation, cross-correlation vector, autocorrelation coefficient, matrix Fujji etc.). The equipment is designed so that it can be taken directly to the site where the sample for biological study and is currently being used in research projects within the group.

  14. A direct-to-drive neural data acquisition system.

    PubMed

    Kinney, Justin P; Bernstein, Jacob G; Meyer, Andrew J; Barber, Jessica B; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T; Kopell, Nancy J; Boyden, Edward S

    2015-01-01

    Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future. PMID:26388740

  15. Acquisition/expulsion system for earth orbital propulsion system study. Volume 5: Earth storable design

    NASA Technical Reports Server (NTRS)

    1973-01-01

    A comprehensive analysis and parametric design effort was conducted under the earth-storable phase of the program. Passive Acquisition/expulsion system concepts were evaluated for a reusable Orbital Maneuvering System (OMS) application. The passive surface tension technique for providing gas free liquid on demand was superior to other propellant acquisition methods. Systems using fine mesh screens can provide the requisite stability and satisfy OMS mission requirements. Both fine mesh screen liner and trap systems were given detailed consideration in the parametric design, and trap systems were selected for this particular application. These systems are compatible with the 100- to 500-manned mission reuse requirements.

  16. Data acquisition system based on the Nios II for a CCD camera

    NASA Astrophysics Data System (ADS)

    Li, Binhua; Hu, Keliang; Wang, Chunrong; Liu, Yangbing; He, Chun

    2006-06-01

    The FPGA with Avalon Bus architecture and Nios soft-core processor developed by Altera Corporation is an advanced embedded solution for control and interface systems. A CCD data acquisition system with an Ethernet terminal port based on the TCP/IP protocol is implemented in NAOC, which is composed of a piece of interface board with an Altera's FPGA, 32MB SDRAM and some other accessory devices integrated on it, and two packages of control software used in the Nios II embedded processor and the remote host PC respectively. The system is used to replace a 7200 series image acquisition card which is inserted in a control and data acquisition PC, and to download commands to an existing CCD camera and collect image data from the camera to the PC. The embedded chip in the system is a Cyclone FPGA with a configurable Nios II soft-core processor. Hardware structure of the system, configuration for the embedded soft-core processor, and peripherals of the processor in the PFGA are described. The C program run in the Nios II embedded system is built in the Nios II IDE kits and the C++ program used in the PC is developed in the Microsoft's Visual C++ environment. Some key techniques in design and implementation of the C and VC++ programs are presented, including the downloading of the camera commands, initialization of the camera, DMA control, TCP/IP communication and UDP data uploading.

  17. Neurophysiological indices of strategy development and skill acquisition.

    PubMed

    Smith, M E; McEvoy, L K; Gevins, A

    1999-01-01

    In order to examine neurophysiological changes associated with the development of cognitive and visuomotor strategies and skills, spectral features of the EEG were measured as participants learned to perform new tasks. In one experiment eight individuals practiced working memory tasks that required development of either spatial or verbal rehearsal and updating strategies. In a second experiment six individuals practiced a video game with a difficult visuomotor tracking component. The alpha rhythm, which is attenuated by functional cortical activation, was affected by task practice. In both experiments, a lower-frequency, centrally distributed alpha component increased between practice sessions in a task-independent fashion, reflecting an overall decrease in the extent of cortical activation after practice. A second, higher-frequency, posterior component of the alpha rhythm displayed task-specific practice effects. Practice in the verbal working memory task resulted in an increase of this signal over right posterior regions, an effect not seen after practice with the spatial working memory task or with the video game. This between-task difference presumably reflects a continued involvement of the posterior region of the right hemisphere in tasks that invoke visuospatial processes. This finding thus provides neurophysiological evidence for the formation of a task-specific neurocognitive strategy. In the second experiment a third component of the alpha rhythm, localized over somatomotor cortex, was enhanced in conjunction with acquisition of tracking skill. These alpha band results suggest that cortical regions not necessary for task performance become less active as skills develop. In both experiments the frontal midline (Fm) theta rhythm also displayed increases over the course of test sessions. This signal is associated with states of focused concentration, and its enhancement might reflect the conscious control over attention associated with maintenance of a task

  18. 75 FR 49016 - County of Greenville, S.C.-Acquisition Exemption-Greenville County Economic Development Corporation

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-12

    ... Greenville County Economic Development Corporation (GCEDC) approximately 11.8 miles of rail line between... accordance with the National Trails System Act, 16 U.S.C. 1247(d). See Greenville County Economic Development... Surface Transportation Board County of Greenville, S.C.--Acquisition Exemption--Greenville County...

  19. RF and data acquisition systems for Fermilab's ILC SRF cavity vertical test stand

    SciTech Connect

    Ozelis, Joseph P.; Nehring, Roger; Grenoble, Christiana; Powers, Thomas J.; /Jefferson Lab

    2007-06-01

    Fermilab is developing a facility for vertical testing of SRF cavities as part of its ILC program. The RF system for this facility is based on the proven production cavity test systems used at Jefferson Lab for CEBAF and SNS cavity testing. The design approach is modular in nature, using commercial-off-the-shelf (COTS) components. This yields a system that can be easily debugged and modified, and with ready availability of spares. Comprehensive data acquisition and control is provided by a PXI-based hardware platform in conjunction with software developed in the LabView programming environment.

  20. VME-based data acquisition system for the India-based Neutrino Observatory prototype detector

    NASA Astrophysics Data System (ADS)

    Bhuyan, M.; Chandratre, V. B.; Dasgupta, S.; Datar, V. M.; Kalmani, S. D.; Lahamge, S. M.; Mondal, N. K.; Nagaraj, P.; Pal, S.; Rao, S. K.; Redij, A.; Samuel, D.; Saraf, M. N.; Satyanarayana, B.; Shinde, R. R.; Upadhya, S. S.

    2012-01-01

    The India-based Neutrino Observatory (INO) collaboration has proposed to build a 50 kton Iron-Calorimeter (ICAL) to study neutrino oscillations. About 28,800 Resistive Plate Chambers will be used as active detector elements in this experiment. Preliminary studies are currently underway and as a part of it, a prototype detector was developed which now serves as a cosmic-ray telescope and as a test-bench to study the indigenously built RPCs. A VME-based data acquisition system was designed for this prototype system. Modern software tools were used in the designing of the DAQ software. The design and development of this DAQ system are discussed.

  1. Diagnostic-management system and test pulse acquisition for WEST plasma measurement system

    NASA Astrophysics Data System (ADS)

    Wojenski, A.; Kasprowicz, G.; Pozniak, K. T.; Byszuk, A.; Juszczyk, B.; Zabolotny, W.; Zienkiewicz, P.; Chernyshova, M.; Czarski, T.; Mazon, D.; Malard, P.

    2014-11-01

    This paper describes current status of electronics, firmware and software development for new plasma measurement system for use in WEST facility. The system allows to perform two dimensional plasma visualization (in time) with spectrum measurement. The analog front-end is connected to Gas Electron Multiplier detector (GEM detector). The system architecture have high data throughput due to use of PCI-Express interface, Gigabit Transceivers and sampling frequency of ADC integrated circuits. The hardware is based on several years of experience in building X-ray spectrometer system for Joint European Torus (JET) facility. Data streaming is done using Artix7 FPGA devices. The system in basic configuration can work with up to 256 channels, while the maximum number of measurement channels is 2048. Advanced firmware for the FPGA is required in order to perform high speed data streaming and analog signal sampling. Diagnostic system management has been developed in order to configure measurement system, perform necessary calibration and prepare hardware for data acquisition.

  2. Design of a Second Generation Firewire Based Data Acquisition System for Small Animal PET Scanners

    PubMed Central

    Lewellen, T.K.; Miyaoka, R.S.; MacDonald, L.R.; Haselman, M.; DeWitt, D.; Hunter, William; Hauck, S.

    2009-01-01

    The University of Washington developed a Firewire based data acquisition system for the MiCES small animal PET scanner. Development work has continued on new imaging scanners that require more data channels and need to be able to operate within a MRI imaging system. To support these scanners, we have designed a new version of our data acquisition system that leverages the capabilities of modern field programmable gate arrays (FPGA). The new design preserves the basic approach of the original system, but puts almost all functions into the FPGA, including the Firewire elements, the embedded processor, and pulse timing and pulse integration. The design has been extended to support implementation of the position estimation and DOl algorithms developed for the cMiCE detector module. The design is centered around an acquisition node board (ANB) that includes 65 ADC channels, Firewire 1394b support, the FPGA, a serial command bus and signal lines to support a rough coincidence window implementation to reject singles events from being sent on the Firewire bus. Adapter boards convert detector signals into differential paired signals to connect to the ANB. PMID:20228958

  3. Infrared spectrometry studies: Spectral digital data acquisition system (1971 version)

    NASA Technical Reports Server (NTRS)

    Lu, L.; Lyon, R. J. P.

    1971-01-01

    The construction of the Stanford Spectral Digital Data Acquisition System is described. The objective of the system is to record both the spectral distribution of incoming radiation from the rock samples measured by the spectroradiometer (Exotech Model 10-34 Circular Variable Filter Infrared Spectroradiometer) together with other weather information. This system is designed for both laboratory and field measurement programs. The multichannel inputs (8 channels) of the system are as follows: Ch 1 the Spectro-radiometer, Ch 2 the radiometer (PRT-5), and Ch 3 to Ch 8 for the weather information. The system records data from channel 1 and channel 2 alternately for 48 times, before a fast sweep across the six weather channels, to form a single scan in the scan counter. The operation is illustrated in a block diagram, and the theory of operation is described. The outputs are written on a 7-track magnetic tape with IBM compatible form. The format of the tape and the playback computer programs are included. The micro-pac digital modules and a CIPHER model 70 tape recorder (Cipher Data Products) are used. One of the major characteristics of this system is that it is externally clocked by the spectroradiometer instead of taking data at intervals of various wavelengths by using internal-clocking.

  4. ASRC Aerospace Corporation Selects Dynamically Reconfigurable Anadigm(Registered Trademark) FPAA For Advanced Data Acquisition System

    NASA Technical Reports Server (NTRS)

    Mata, Carlos T.

    2003-01-01

    Anadigm(registered trademark) today announced that ASRC Aerospace Corporation has designed Anadigm's dynamically reconfigurable Field Programmable Analog Array (FPAA) technology into an advanced data acquisition system developed under contract for NASA. ASRC Aerospace designed in the Anadigm(registered trademark) FPAA to provide complex analog signal conditioning in its intelligent, self-calibrating, and self-healing advanced data acquisition system (ADAS). The ADAS has potential applications in industrial, manufacturing, and aerospace markets. This system offers highly reliable operation while reducing the need for user interaction. Anadigm(registered trademark)'s dynamically reconfigurable FPAAs can be reconfigured in-system by the designer or on the fly by a microprocessor. A single device can thus be programmed to implement multiple analog functions and/or to adapt on-the-fly to maintain precision operation despite system degradation and aging. In the case of the ASRC advanced data acquisition system, the FPAA helps ensure that the system will continue to operating at 100% functionality despite changes in the environment, component degradation, and/or component failures.

  5. The Data Acquisition and Control Systems of the Jet Noise Laboratory at the NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Jansen, B. J., Jr.

    1998-01-01

    The features of the data acquisition and control systems of the NASA Langley Research Center's Jet Noise Laboratory are presented. The Jet Noise Laboratory is a facility that simulates realistic mixed flow turbofan jet engine nozzle exhaust systems in simulated flight. The system is capable of acquiring data for a complete take-off assessment of noise and nozzle performance. This paper describes the development of an integrated system to control and measure the behavior of model jet nozzles featuring dual independent high pressure combusting air streams with wind tunnel flow. The acquisition and control system is capable of simultaneous measurement of forces, moments, static and dynamic model pressures and temperatures, and jet noise. The design concepts for the coordination of the control computers and multiple data acquisition computers and instruments are discussed. The control system design and implementation are explained, describing the features, equipment, and the experiences of using a primarily Personal Computer based system. Areas for future development are examined.

  6. Low-power analog integrated circuits for wireless ECG acquisition systems.

    PubMed

    Tsai, Tsung-Heng; Hong, Jia-Hua; Wang, Liang-Hung; Lee, Shuenn-Yuh

    2012-09-01

    This paper presents low-power analog ICs for wireless ECG acquisition systems. Considering the power-efficient communication in the body sensor network, the required low-power analog ICs are developed for a healthcare system through miniaturization and system integration. To acquire the ECG signal, a low-power analog front-end system, including an ECG signal acquisition board, an on-chip low-pass filter, and an on-chip successive-approximation analog-to-digital converter for portable ECG detection devices is presented. A quadrature CMOS voltage-controlled oscillator and a 2.4 GHz direct-conversion transmitter with a power amplifier and upconversion mixer are also developed to transmit the ECG signal through wireless communication. In the receiver, a 2.4 GHz fully integrated CMOS RF front end with a low-noise amplifier, differential power splitter, and quadrature mixer based on current-reused folded architecture is proposed. The circuits have been implemented to meet the specifications of the IEEE 802.15.4 2.4 GHz standard. The low-power ICs of the wireless ECG acquisition systems have been fabricated using a 0.18 μm Taiwan Semiconductor Manufacturing Company (TSMC) CMOS standard process. The measured results on the human body reveal that ECG signals can be acquired effectively by the proposed low-power analog front-end ICs. PMID:22374371

  7. Research into the development of a knowledge acquisition taxonomy

    NASA Technical Reports Server (NTRS)

    Fink, Pamela K.; Herren, L. Tandy

    1991-01-01

    The focus of the research was on the development of a problem solving taxonomy that can support and direct the knowledge engineering process during the development of an intelligent tutoring system. The results of the research are necessarily general. Being only a small initial attempt at a fundamental problem in artificial intelligence and cognitive psychology, the process has had to be bootstrapped and the results can only provide pointers to further, more formal research designs.

  8. The Development of Theories of Second Language Acquisition

    ERIC Educational Resources Information Center

    Myles, Florence

    2010-01-01

    Second language acquisition (SLA) is a relatively new field of enquiry. Before the late 1960s, educators did write about L2 learning, but very much as an adjunct of language teaching pedagogy, underpinned by behaviourism, the then-dominant learning theory in psychology. In this view, the task facing learners of foreign languages was to rote-learn…

  9. DEVELOPMENT OF MARKETABLE TYPING SKILL--SENSORY PROCESSES UNDERLYING ACQUISITION.

    ERIC Educational Resources Information Center

    WEST, LEONARD J.

    THE PROJECT ATTEMPTED TO PROVIDE FURTHER DATA ON THE DOMINANT HYPOTHESIS ABOUT THE SENSORY MECHANISMS UNDERLYING SKILL ACQUISITION IN TYPEWRITING. IN SO DOING, IT PROPOSED TO FURNISH A BASIS FOR IMPORTANT CORRECTIVES TO SUCH CONVENTIONAL INSTRUCTIONAL PROCEDURES AS TOUCH TYPING. SPECIFICALLY, THE HYPOTHESIS HAS BEEN THAT KINESTHESIS IS NOT…

  10. 15 CFR 921.21 - Initial acquisition and development awards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the state, as provided by Department of Commerce regulations at 15 CFR part 24, and Uniform Relocation Assistance and Real Property Acquisition for Federal and Federally assisted programs at 15 CFR part 11. (f... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN...

  11. 15 CFR 921.21 - Initial acquisition and development awards.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the state, as provided by Department of Commerce regulations at 15 CFR part 24, and Uniform Relocation Assistance and Real Property Acquisition for Federal and Federally assisted programs at 15 CFR part 11. (f... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN...

  12. 15 CFR 921.21 - Initial acquisition and development awards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the state, as provided by Department of Commerce regulations at 15 CFR part 24, and Uniform Relocation Assistance and Real Property Acquisition for Federal and Federally assisted programs at 15 CFR part 11. (f... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN...

  13. Downsizings, Mergers, and Acquisitions: Perspectives of Human Resource Development Practitioners

    ERIC Educational Resources Information Center

    Shook, LaVerne; Roth, Gene

    2011-01-01

    Purpose: This paper seeks to provide perspectives of HR practitioners based on their experiences with mergers, acquisitions, and/or downsizings. Design/methodology/approach: This qualitative study utilized interviews with 13 HR practitioners. Data were analyzed using a constant comparative method. Findings: HR practitioners were not involved in…

  14. 15 CFR 921.21 - Initial acquisition and development awards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the state, as provided by Department of Commerce regulations at 15 CFR part 24, and Uniform Relocation Assistance and Real Property Acquisition for Federal and Federally assisted programs at 15 CFR part 11. (f... Trade (Continued) NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE OCEAN...

  15. Wearable data acquisition system of multimodal physiological signals for personal health care.

    PubMed

    Annus, Paul; Samieipour, Ali; Rist, Marek; Ruiso, Indrek; Krivoshei, Andrei; Land, Raul; Parve, Toomas; Min, Mart

    2013-01-01

    The paper proposes a wearable multimodal data acquisition system for biological signals. The system enables logging of electrical bioimpedance signals from multiple electrodes, electrocardiographic signals (ECG), acceleration signals from multiple locations, and spirometric data from a moving object. Later it will be used to conduct field measurements for characterizing health of the object under investigation. Main goal is to acquire enough data for development, refinement, and simplification of signal processing algorithms. The system is center part of the new wearable compact data acquisition modules ZCardio. Those modules enable multichannel impedance spectroscopy by logging ECG signals and data from the spirometric sensor. Initial reference measurements were conducted. Alternatively, tests were performed using Plessey Semiconductors capacitive sensors. Acceleration signals are gathered. PMID:23739367

  16. Knowledge acquisition and rapid protyping of an expert system: Dealing with real world problems

    NASA Technical Reports Server (NTRS)

    Bailey, Patrick A.; Doehr, Brett B.

    1988-01-01

    The knowledge engineering and rapid prototyping phases of an expert system that does fault handling for a Solid Amine, Water Desorbed CO2 removal assembly for the Environmental Control and Life Support System for space based platforms are addressed. The knowledge acquisition phase for this project was interesting because it could not follow the textbook examples. As a result of this, a variety of methods were used during the knowledge acquisition task. The use of rapid prototyping and the need for a flexible prototype suggested certain types of knowledge representation. By combining various techniques, a representative subset of faults and a method for handling those faults was achieved. The experiences should prove useful for developing future fault handling expert systems under similar constraints.

  17. A hybrid data acquisition system for magnetic measurements of accelerator magnets

    SciTech Connect

    Wang, X.; Hafalia, R.; Joseph, J.; Lizarazo, J.; Martchevsky, M.; Sabbi, G. L.

    2011-06-03

    A hybrid data acquisition system was developed for magnetic measurement of superconducting accelerator magnets at LBNL. It consists of a National Instruments dynamic signal acquisition (DSA) card and two Metrolab fast digital integrator (FDI) cards. The DSA card records the induced voltage signals from the rotating probe while the FDI cards records the flux increment integrated over a certain angular step. This allows the comparison of the measurements performed with two cards. In this note, the setup and test of the system is summarized. With a probe rotating at a speed of 0.5 Hz, the multipole coefficients of two magnets were measured with the hybrid system. The coefficients from the DSA and FDI cards agree with each other, indicating that the numerical integration of the raw voltage acquired by the DSA card is comparable to the performance of the FDI card in the current measurement setup.

  18. The Los Alamos Neutron Scattering Center data acquisition system

    SciTech Connect

    Nelson, R.O.; Cort, G.; Gjovig, A.; Goldstone, J.A.; McMillan, D.E.; Ross, J.; Seal, J.; Machen, D.R.

    1987-05-20

    The FASTBUS subsystem of the LANSCE data acquisition system consists of a single FASTBUS crate segment with four custom modules and a QPI interface for the VAX. Since experiments at the LANSCE facility always include a time-of-flight parameter for the detected neutron and may optionally include additional position parameters characterizing the event, a time stamp is generated for each event by the Programmable Master Clock (PMC) module. The time and any position information are latched into the Time-Of-Flight buffer (TOF) module. After all events associated with a single neutron burst have been captured in a frame buffer internal to the TOF module, each event is analyzed by the MAPPER module and reduced to a histogram address to increment in the BULKSTORE module. Software access to the histogram is provided through the QPI interface.

  19. Single transmission line interrogated multiple channel data acquisition system

    DOEpatents

    Fasching, George E.; Keech, Jr., Thomas W.

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  20. Advanced Signal Conditioners for Data-Acquisition Systems

    NASA Technical Reports Server (NTRS)

    Lucena, Angel; Perotti, Jose; Eckhoff, Anthony; Medelius, Pedro

    2004-01-01

    Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the

  1. Integration of the Trigger and Data Acquisition Systems in ATLAS

    SciTech Connect

    Abolins, M.; Adragna, P.; Aleksandrov, E.; Aleksandrov, I.; Amorim, A.; Anderson, K.; Anduaga, X.; Aracena, I.; Asquith, L.; Avolio, G.; Backlund, S.; Badescu, E.; Baines, J.; Barria, P.; Bartoldus, R.; Batreanu, S.; Beck, H.P.; Bee, C.; Bell, P.; Bell, W.H.; Bellomo, M.; /more authors..

    2011-11-09

    During 2006 and the first half of 2007, the installation, integration and commissioning of trigger and data acquisition (TDAQ) equipment in the ATLAS experimental area have progressed. There have been a series of technical runs using the final components of the system already installed in the experimental area. Various tests have been run including ones where level 1 preselected simulated proton-proton events have been processed in a loop mode through the trigger and dataflow chains. The system included the readout buffers containing the events, event building, level 2 and event filter trigger algorithms. The scalability of the system with respect to the number of event building nodes used has been studied and quantities critical for the final system, such as trigger rates and event processing times, have been measured using different trigger algorithms as well as different TDAQ components. This paper presents the TDAQ architecture, the current status of the installation and commissioning and highlights the main test results that validate the system.

  2. 75 FR 32635 - Defense Acquisition Regulations System; Defense Federal Acquisition Regulation Supplement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... Regulation Supplement; Balance of Payments Program Exemption for Commercial Information Technology... Defense Federal Acquisition Regulation Supplement (DFARS) to implement the exemption from the Balance of... implement in the clauses at 252.225-7044, Balance of Payments Program--Construction Material, and...

  3. Sensors and Data Acquisition Development Efforts at KSC

    NASA Technical Reports Server (NTRS)

    Perotti, Jose M.; Delgado, H. (Technical Monitor)

    2002-01-01

    This viewgraph presentation describes efforts at Kennedy Space Center (KSC) to develop spacecraft sensors and instruments which meet the expected needs of potential clients on a budget. Sensors are profiled, and the topics covered include systems health monitoring, smart structures, software algorithms, and testing.

  4. New methodology of designing inexpensive hybrid control-acquisition systems for mechatronic constructions.

    PubMed

    Augustyn, Jacek

    2013-01-01

    This article presents a new methodology for designing a hybrid control and acquisition system consisting of a 32-bit SoC microsystem connected via a direct Universal Serial Bus (USB) with a standard commercial off-the-shelf (COTS) component running the Android operating system. It is proposed to utilize it avoiding the use of an additional converter. An Android-based component was chosen to explore the potential for a mobile, compact and energy efficient solution with easy to build user interfaces and easy wireless integration with other computer systems. This paper presents results of practical implementation and analysis of experimental real-time performance. It covers closed control loop time between the sensor/actuator module and the Android operating system as well as the real-time sensor data stream within such a system. Some optimisations are proposed and their influence on real-time performance was investigated. The proposed methodology is intended for acquisition and control of mechatronic systems, especially mobile robots. It can be used in a wide range of control applications as well as embedded acquisition-recording devices, including energy quality measurements, smart-grids and medicine. It is demonstrated that the proposed methodology can be employed without developing specific device drivers. The latency achieved was less than 0.5 ms and the sensor data stream throughput was on the order of 750 KB/s (compared to 3 ms latency and 300 KB/s in traditional solutions). PMID:24351633

  5. New Methodology of Designing Inexpensive Hybrid Control-Acquisition Systems for Mechatronic Constructions

    PubMed Central

    Augustyn, Jacek

    2013-01-01

    This article presents a new methodology for designing a hybrid control and acquisition system consisting of a 32-bit SoC microsystem connected via a direct Universal Serial Bus (USB) with a standard commercial off-the-shelf (COTS) component running the Android operating system. It is proposed to utilize it avoiding the use of an additional converter. An Android-based component was chosen to explore the potential for a mobile, compact and energy efficient solution with easy to build user interfaces and easy wireless integration with other computer systems. This paper presents results of practical implementation and analysis of experimental real-time performance. It covers closed control loop time between the sensor/actuator module and the Android operating system as well as the real-time sensor data stream within such a system. Some optimisations are proposed and their influence on real-time performance was investigated. The proposed methodology is intended for acquisition and control of mechatronic systems, especially mobile robots. It can be used in a wide range of control applications as well as embedded acquisition-recording devices, including energy quality measurements, smart-grids and medicine. It is demonstrated that the proposed methodology can be employed without developing specific device drivers. The latency achieved was less than 0.5 ms and the sensor data stream throughput was on the order of 750 KB/s (compared to 3 ms latency and 300 KB/s in traditional solutions). PMID:24351633

  6. Digital data-acquisition system for use with a proton-precession base-station magnetometer

    SciTech Connect

    McPherron, R.L.

    1982-08-26

    At UCLA the base station magnetometer is a Scintrex MB -2 which uses a two inch wide chart record scaled to 100 nT. The magnetometer is also equipped with a digital readout. This is available in BCD format on a 37 pin connector at the back of the instrument. This reading may be recorded digitally if an appropriate data acquisition and storage system is available. The recent development of inexpensive microcomputers and audio cassette recorders provided motivation for our exploration group to develop a digital data acquisition system for the existing base station magnetometer. A block diagram of the data acquisition system is presented. The microcomputer utilizes a R6502 as the central processor. Data are entered into the computer via a 12 key keypad and are displayed on a 6 digit liquid crystal display. Data from the Scintrex base magnetometer is passed to the microcomputer via a 37 line connector. One line of this connector is used to signal the status of the internally controlled sampling circuit in the base station magnetometer. Digital data are stored temporarily in RAM memory until an output buffer is filled. When this occurs power is applied to the audio cassette tape transport mechanism and after a short delay a block of data is written onto tape. The tape interface implements the Kansas City standard which is nearly universally used for microcomputer recording on audio cassette recorders. The entire system is powered by the same 12V dc battery used by the base station magnetometer. (WHK)

  7. A wireless data acquisition system for acoustic emission testing

    NASA Astrophysics Data System (ADS)

    Zimmerman, A. T.; Lynch, J. P.

    2013-01-01

    As structural health monitoring (SHM) systems have seen increased demand due to lower costs and greater capabilities, wireless technologies have emerged that enable the dense distribution of transducers and the distributed processing of sensor data. In parallel, ultrasonic techniques such as acoustic emission (AE) testing have become increasingly popular in the non-destructive evaluation of materials and structures. These techniques, which involve the analysis of frequency content between 1 kHz and 1 MHz, have proven effective in detecting the onset of cracking and other early-stage failure in active structures such as airplanes in flight. However, these techniques typically involve the use of expensive and bulky monitoring equipment capable of accurately sensing AE signals at sampling rates greater than 1 million samples per second. In this paper, a wireless data acquisition system is presented that is capable of collecting, storing, and processing AE data at rates of up to 20 MHz. Processed results can then be wirelessly transmitted in real-time, creating a system that enables the use of ultrasonic techniques in large-scale SHM systems.

  8. 75 FR 41097 - Homeland Security Acquisition Regulation; Lead System Integrators [HSAR Case 2009-003

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-15

    ... Acquisition Regulation; Lead System Integrators AGENCY: Office of the Chief Procurement Officer, DHS. ACTION... lead system integrators in the acquisition of DHS major systems if they have direct financial interests... 6 U.S.C. 396; hereinafter ``Section 396''), limits firms that can serve as lead system...

  9. LOLA; Library On-Line Acquisitions Sub-System, Washington State University.

    ERIC Educational Resources Information Center

    Burgess, T.; Ames, L.

    The Acquisitions System is just one segment of an overall system design that was made for the entire Technical Services System of the Washington State University Library. After an overall study of the Technical Services System was conducted, a detailed study was made of work in the Acquisitions Department, and the Telecommunications Control…

  10. A wireless high-speed data acquisition system for geotechnical centrifuge model testing

    NASA Astrophysics Data System (ADS)

    Gaudin, C.; White, D. J.; Boylan, N.; Breen, J.; Brown, T.; DeCatania, S.; Hortin, P.

    2009-09-01

    This paper describes a novel high-speed wireless data acquisition system (WDAS) developed at the University of Western Australia for operation onboard a geotechnical centrifuge, in an enhanced gravitational field of up to 300 times Earth's gravity. The WDAS system consists of up to eight separate miniature units distributed around the circumference of a 0.8 m diameter drum centrifuge, communicating with the control room via wireless Ethernet. Each unit is capable of powering and monitoring eight instrument channels at a sampling rate of up to 1 MHz at 16-bit resolution. The data are stored within the logging unit in solid-state memory, but may also be streamed in real-time at low frequency (up to 10 Hz) to the centrifuge control room, via wireless transmission. The high-speed logging runs continuously within a circular memory (buffer), allowing for storage of a pre-trigger segment of data prior to an event. To suit typical geotechnical modelling applications, the system can record low-speed data continuously, until a burst of high-speed acquisition is triggered when an experimental event occurs, after which the system reverts back to low-speed acquisition to monitor the aftermath of the event. Unlike PC-based data acquisition solutions, this system performs the full sequence of amplification, conditioning, digitization and storage on a single circuit board via an independent micro-controller allocated to each pair of instrumented channels. This arrangement is efficient, compact and physically robust to suit the centrifuge environment. This paper details the design specification of the WDAS along with the software interface developed to control the units. Results from a centrifuge test of a submarine landslide are used to illustrate the performance of the new WDAS.

  11. Secondary particle acquisition system for the CERN beam wire scanners upgrade

    NASA Astrophysics Data System (ADS)

    Sirvent, J. L.; Dehning, B.; Emery, J.; Diéguez, A.

    2015-04-01

    The increasing requirements of CERN experiments make essential the upgrade of beam instrumentation in general, and high accuracy beam profile monitors in particular. The CERN Beam Instrumentation Group has been working during the last years on the Wire Scanners upgrade. These systems cross a thin wire through a circulating beam, the resulting secondary particles produced from beam/wire interaction are detected to reconstruct the beam profile. For the new secondary shower acquisition system, it is necessary to perform very low noise measurements with high dynamic range coverage. The aim is to design a system without tuneable parameters and compatible for any beam wire scanner location at the CERN complex. Polycrystalline chemical vapour deposition diamond detectors (pCVD) are proposed as new detectors for this application because of their radiation hardness, fast response and linearity over a high dynamic range. For the detector readout, the acquisition electronics must be designed to exploit the detector capabilities and perform bunch by bunch measurements at 40MHz. This paper describes the design challenges of such a system, analysing different acquisition possibilities from the signal integrity point of view. The proposed system architecture is shown in detail and the development status presented.

  12. Improvement of web-based data acquisition and management system for GOSAT validation lidar data analysis

    NASA Astrophysics Data System (ADS)

    Okumura, Hiroshi; Takubo, Shoichiro; Kawasaki, Takeru; Abdullah, Indra Nugraha; Uchino, Osamu; Morino, Isamu; Yokota, Tatsuya; Nagai, Tomohiro; Sakai, Tetsu; Maki, Takashi; Arai, Kohei

    2013-01-01

    A web-base data acquisition and management system for GOSAT (Greenhouse gases Observation SATellite) validation lidar data-analysis has been developed. The system consists of data acquisition sub-system (DAS) and data management sub-system (DMS). DAS written in Perl language acquires AMeDAS (Automated Meteorological Data Acquisition System) ground-level local meteorological data, GPS Radiosonde upper-air meteorological data, ground-level oxidant data, skyradiometer data, skyview camera images, meteorological satellite IR image data and GOSAT validation lidar data. DMS written in PHP language demonstrates satellite-pass date and all acquired data. In this article, we briefly describe some improvement for higher performance and higher data usability. GPS Radiosonde upper-air meteorological data and U.S. standard atmospheric model in DAS automatically calculate molecule number density profiles. Predicted ozone density prole images above Saga city are also calculated by using Meteorological Research Institute (MRI) chemistry-climate model version 2 for comparison to actual ozone DIAL data.

  13. Hybrid control and data acquisition system for geographically distributed sensors for environmental monitoring

    NASA Astrophysics Data System (ADS)

    Garufi, Fabio; Acernese, Fausto; Boiano, Alfonso; De Rosa, Rosario; Romano, Rocco; Barone, Fabrizio

    2007-10-01

    In this paper we describe the architecture and the performances of a hybrid modular acquisition and control system prototype for environmental monitoring and geophysics. The system, an improvement of a VME-UDP/IP based system we developed for interferometric detectors of gravitational waves, is based on a dual-channel 18-bit low noise ADC, a 16-bit DAC module at 1MHz, and a 20-bit slower ADC necessary for the acquisition of an external calibration signal. The module can be configured as stand-alone or mounted on a motherboard as mezzanine in parallel with other modules. Both the modules and the motherboard can send/receive the configuration and the acquired/correction data for control through a standard EPP parallel port to a standard PC, where the real-time computation is performed. Experimental tests have demonstrated that the distributed control systems implemented with this architecture exihibit a delay time of less than 25 μs on a single channel, that is a sustained sampling frequency of more than 40kHz. The system is now under extensive test in two different experiments: the remote control and data acquisition of a set of seismometers, velocimeters and accelerometers to simulate a geophysics networks of sensors and the remote control of the end mirrors of a suspended Michelson interferometer through electrostatic actuators for interferometric detectors of gravitational waves.

  14. Feasibility of a driver performance data acquisition system

    SciTech Connect

    Carter, R.J.; Spelt, P.F.; Goodman, M.J.

    1994-06-01

    The National Highway Traffic Safety Administration (NHTSA) envisions many future situations in which the effectiveness and consequences of new intelligent vehicle-highway systems technologies will need to be studied in actual production vehicles. Such studies will enable evaluations in vehicles which are familiar to drivers. These studies would be future enhanced by the availability of an instrumentation package that can be easily installed in these vehicles to enable specific vehicle configurations of interest to be evaluated, thereby increasing the variety of vehicle options that are available for study. Ideally, an approach is needed that would allow data collection from a variety of vehicle models and types, and would address the issue of driver familiarity. Such an approach is embodied in the concept of a driver performance data acquisition system that could be installed in a wide range of vehicles within a relatively short period of time. As a universally adaptable system, it would provide researchers with the ability to manually input data as well as directly record information on driver, vehicle, roadway, and environmental parameters. Furthermore, it would enable the measurement of driver performance in the driver`s own vehicle, thereby ensuring vehicle familiarity. In addition, it would be possible to measure driver performance in relation to any vehicle design characteristic at relatively little expense and effort, and would make it easy to update existing models of driver/vehicle behavior to reflect performance characteristics in vehicles of current manufacture.

  15. 77 FR 47797 - Federal Acquisition Regulation; Small Business Set Asides for Research and Development Contracts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-10

    ... 9000-AM33 Federal Acquisition Regulation; Small Business Set Asides for Research and Development... to amend the Federal Acquisition Regulation (FAR) to clarify that contracting officers shall set... revise paragraph (b)(2) of FAR 19.502-2, ``Total small business set-asides,'' to clarify that...

  16. Data acquisition system with pulse height capability for the TOFED time-of-flight neutron spectrometer

    SciTech Connect

    Chen, Z. J.; Peng, X. Y.; Zhang, X.; Du, T. F.; Hu, Z. M.; Cui, Z. Q.; Ge, L. J.; Xie, X. F.; Yuan, X.; Li, X. Q.; Zhang, G. H.; Chen, J. X.; Fan, T. S.; Gorini, G.; Nocente, M.; Tardocchi, M.; Hu, L. Q.; Zhong, G. Q.; Lin, S. Y.; Wan, B. N.

    2014-11-15

    A new time-of-flight neutron spectrometer TOFED has been constructed for installation at Experimental Advanced Superconducting Tokamak. A data acquisition system combining measurements of flight time and energy from the interaction of neutrons with the TOFED scintillators has been developed. The data acquisition system can provide a digitizing resolution better than 1.5% (to be compared with the >10% resolution of the recoil particle energy in the plastic scintillators) and a time resolution <1 ns. At the same time, it is compatible with high count rate event recording, which is an essential feature to investigate phenomena occurring on time scales faster than the slowing down time (≈100 ms) of the beam ions in the plasma. Implications of these results on the TOFED capability to resolve fast ion signatures in the neutron spectrum from EAST plasmas are discussed.

  17. [A rapid fetal ECG acquisition system based on FT245RL].

    PubMed

    Fu, Binggen; Yang, Zuyuan; Cai, Kun; Xie, Shengli

    2014-11-01

    A rapid fetal ECG signal acquisition system is designed, which includes three modules: a front-end signal acquisition module, a micro control module and a PC software application module. The first two modules are accomplished through the ADS1294 and the STM32F103 chips, respectively, and the third one is developed in VC++ platform. By using the FT245RL chip, the proposed system implements the serial-parallel conversion communication between ARM and PC, improving the data transmission rate largely. Also, it has a simple structure, with low power consumption and high precision. Furthermore, it can collect fetal ECG signals from mother's abdominal wall and convert them into the 24-bit digital signals. PMID:25980129

  18. In application specific integrated circuit and data acquisition system for digital X-ray imaging

    NASA Astrophysics Data System (ADS)

    Beuville, E.; Cederström, B.; Danielsson, M.; Luo, L.; Nygren, D.; Oltman, E.; Vestlund, J.

    1998-02-01

    We have developed an Application Specific Integrated Circuit (ASIC) and data acquisition system for digital X-ray imaging. The chip consists of 16 parallel channels, each containing preamplifier, shaper, comparator and a 16 bit counter. We have demonstrated noiseless single-photon counting over a threshold of 7.2 keV using Silicon detectors and are presently capable of maximum counting rates of 2 MHz per channel. The ASIC is controlled by a personal computer through a commercial PCI card, which is also used for data acquisition. The content of the 16 bit counters are loaded into a shift register and transferred to the PC at any time at a rate of 20 MHz. The system is non-complicated, low cost and high performance and is optimised for digital X-ray imaging applications.

  19. A prototype data acquisition and processing system for Schumann resonance measurements

    NASA Astrophysics Data System (ADS)

    Tatsis, Giorgos; Votis, Constantinos; Christofilakis, Vasilis; Kostarakis, Panos; Tritakis, Vasilis; Repapis, Christos

    2015-12-01

    In this paper, a cost-effective prototype data acquisition system specifically designed for Schumann resonance measurements and an adequate signal processing method are described in detail. The implemented system captures the magnetic component of the Schumann resonance signal, using a magnetic antenna, at much higher sampling rates than the Nyquist rate for efficient signal improvement. In order to obtain the characteristics of the individual resonances of the SR spectrum a new and efficient software was developed. The processing techniques used in this software are analyzed thoroughly in the following. Evaluation of system's performance and operation is realized using preliminary measurements taken in the region of Northwest Greece.

  20. ICH rf system data acquisition and real time control using a microcomputer system

    SciTech Connect

    Cary, W.P.; Allen, J.A.; Pinsker, R.I.; Petty, C.C.

    1993-10-01

    On the basis of the rapidly increasing power, speed, and decreasing cost of the personal computer (microcomputer) it was felt that a real time data acquisition and control system could be configured quickly and very cost effectively. It was further felt that by using a high level or object-oriented programming language that considerable time and expense could be saved and at the same time increase system flexibility. This paper will attempt to address the desired system requirements and performance for both the control of the high power transmitters and for the data acquisition and presentation of the information.