Science.gov

Sample records for acquity uplc column

  1. A Fast and Reliable UPLC-PAD Fingerprint Analysis of Chimonanthus salicifolius Combined with Chemometrics Methods.

    PubMed

    Liang, Xianrui; Zhao, Cui; Su, Weike

    2016-08-01

    A novel fingerprinting approach was developed by means of ultra-high-performance liquid chromatography with photodiode array detector (UPLC-PAD) for the quality control of Chimonanthus salicifolius (C. salicifolius). All UPLC analyses were carried out on a Waters Acquity BEH Phenyl column (2.1 × 50 mm, 1.7 μm particle size) at 48°C, with a gradient mobile phase composed of 0.1% aqueous phosphoric acid and acetonitrile at a flow rate of 0.2 mL/min. The method validation results demonstrated the developed method possessing desirable precision [<0.88% relative standard deviation (RSD)], reproducibility (<1.87% RSD), stability (<1.42% RSD) and allowing fingerprint analysis in one chromatographic run within 21 min. The quality assessment was achieved by using chemometrics methods including similarity analysis, hierarchical clustering analysis and principal component analysis. The developed method can be used for further quality control of C. salicifolius.

  2. Simultaneous Quantification of Ten Active Components in Traditional Chinese Formula Sijunzi Decoction Using a UPLC-PDA Method.

    PubMed

    An, Kang; Jin-Rui, Guo; Zhen, Zhang; Xiao-Long, Wang

    2014-01-01

    Sijunzi decoction (SJZT), a traditional Chinese formula (TCMF) consisting of four herbs, has been widely used for the treatment of various gastrointestinal symptoms. However, its modernization process is hindered by the lack of a powerful quality control method that covers the major active components in the formula. The aim of this study was to establish a UPLC method for the quantitative determination of ten active components in Sijunzi decoction including ginsenoside Rg1, Re, Rb1, liquiritin, liquiritigenin, glycyrrhizic acid, atractylenolide I, atractylenolide II, atractylenolide III, and pachymic acid. Separation was achieved using an ACQUITY UPLC BEHC18 column (2.1 mm × 100 mm, 1.7  μ m) with a gradient elution program consisting of acetonitrile and 0.1% phosphoric acid solution. The detection wavelengths were set at 203, 254, 222, and 267 nm. The method was validated for linearity, accuracy, precision, limit of detection, and limit of quantification. The validated method was successfully applied to the simultaneous quantification of ten active compounds from several finished batches of SJZT. This validated that UPLC method is expected to provide a new basis for the quality control of SJZT.

  3. A rapid UPLC-MS/MS assay for eicosanoids in human plasma: Application to evaluate niacin responsivity.

    PubMed

    Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K

    2017-01-18

    A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response.

  4. Determination of Asymmetric and Symmetric Dimethylarginine in Serum from Patients with Chronic Kidney Disease: UPLC-MS/MS versus ELISA

    PubMed Central

    Boelaert, Jente; Schepers, Eva; Glorieux, Griet; Eloot, Sunny; Vanholder, Raymond; Lynen, Frédéric

    2016-01-01

    Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide (NO) synthesis, and its structural isomer symmetric dimethylarginine (SDMA) are uremic toxins accumulating in chronic kidney disease (CKD) patients. The objective of this study was to develop and validate a robust UPLC-MS/MS method for the simultaneous determination of ADMA and SDMA in human serum. Chromatographic separation after butyl ester derivatization was achieved on an Acquity UPLC BEH C18 column, followed by tandem mass spectrometric detection. After validation, the applicability of the method was evaluated by the analysis of serum samples from 10 healthy controls and 77 CKD patients on hemodialysis (CKD5HD). Both ADMA (0.84 ± 0.19 µM vs. 0.52 ± 0.07 µM) and SDMA concentrations (2.06 ± 0.82 µM vs. 0.59 ± 0.13 µM) were significantly (p < 0.001) elevated in CKD5HD patients compared to healthy controls. In general, low degrees of protein binding were found for both ADMA and SDMA. In addition, an established commercially available ELISA kit was utilized on the same samples (n = 87) to compare values obtained both with ELISA and UPLC-MS/MS. Regression analysis between these two methods was significant (p < 0.0001) but moderate for both ADMA (R = 0.78) and SDMA (R = 0.72). PMID:27187471

  5. UPLC method for the determination of vitamin E homologues and derivatives in vegetable oils, margarines and supplement capsules using pentafluorophenyl column.

    PubMed

    Wong, Yong Foo; Makahleh, Ahmad; Saad, Bahruddin; Ibrahim, Mohamad Nasir Mohamad; Rahim, Afidah Abdul; Brosse, Nicolas

    2014-12-01

    A sensitive and rapid reversed-phase ultra performance liquid chromatographic (UPLC) method for the simultaneous determination of tocopherols (α-, β-, γ-, δ-), tocotrienols (α-, β-, γ-, δ-), α-tocopherol acetate and α-tocopherol nicotinate is described. The separation was achieved using a Kinetex pentafluorophenyl (PFP) column (150 × 2.1mm, 2.6 µm) with both photodiode array (PDA) and fluorescence (FL) detectors that were connected in series. Column was thermostated at 42°C. Under a gradient system consisting of methanol and water at a constant flow rate of 0.38 mL min(-1), all the ten analytes were well separated in less than 9.5 min. The method was validated in terms of linearity, limits of detection and quantitation, precision and recoveries. Calibration curves of the ten compounds were well correlated (r(2)>0.999) within the range of 100 to 25,000 μg L(-1) for α-tocopherol acetate and α-tocopherol nicotinate, 10 to 25,000 μg L(-1) for α-tocotrienol and 5 to 25,000 μg L(-1) for the other components. The method is simple and sensitive with detection limits (S/N, 3) of 1.0 to 3.0 μg L(-1) (FL detection) and 30 to 74 μg L(-1) (PDA detection). Relative standard deviations for intra- and inter-day retention times (<1%) and peak areas (≤ 4%) were obtained. The method was successfully applied to the determination of vitamin E in vegetable oils (extra virgin olive, virgin olive, pomace olive, blended virgin and refined olive, sunflower, soybean, palm olein, carotino, crude palm, walnut, rice bran and grape seed), margarines and supplements.

  6. High-speed and high-resolution UPLC separation at zero degrees Celsius.

    PubMed

    Wales, Thomas E; Fadgen, Keith E; Gerhardt, Geoff C; Engen, John R

    2008-09-01

    The conformational properties of proteins can be probed with hydrogen/deuterium exchange mass spectrometry (HXMS). In order to maintain the deuterium label during LC/MS analyses, chromatographic separation must be done rapidly (usually in under 8-10 min) and at 0 degrees C. Traditional RP-HPLC with approximately 3-mum particles has shown generally poor chromatographic performance under these conditions and thereby has been prohibitive for HXMS analyses of larger proteins and many protein complexes. Ultraperformance liquid chromatography (UPLC) employs particles smaller than 2 mum in diameter to achieve superior resolution, speed, and sensitivity as compared to HPLC. UPLC has previously been shown to be compatible with the fast separation and low temperature requirements of HXMS. Here we present construction and validation of a custom UPLC system for HXMS. The system is based on the Waters nanoACQUITY platform and contains a Peltier-cooled module that houses the injection and switching valves, online pepsin digestion column, and C-18 analytical separation column. Single proteins in excess of 95 kDa and a four-protein mixture in excess of 250 kDa have been used to validate the performance of this new system. Near-baseline resolution was achieved in 6-min separations at 0 degrees C and displayed a median chromatographic peak width of approximately 2.7 s at half-height. Deuterium recovery was similar to that obtained using a conventional HPLC and ice bath. This new system represents a significant advancement in HXMS technology that is expected to make the technique more accessible and mainstream in the near future.

  7. [Optimization of processing technology for xanthii fructus by UPLC fingerprint technique and contents of toxicity ingredient].

    PubMed

    Han, Yan-Quan; Hong, Yan; Xia, Lun-Zhu; Gao, Jia-Rong; Wang, Yong-Zhong; Sun, Yan-Hua; Yi, Jin-Hai

    2014-04-01

    The experiment's aim was to optimize the processing technology of Xanthii Fructus which through comparing the difference of UPLC fingerprint and contents of toxicity ingredient in water extract of 16 batches of processed sample. The determination condition of UPLC chromatographic and contents of toxicity ingredient were as follows. UPLC chromatographic: ACQUITY BEH C18 column (2.1 mm x 100 mm, 1.7 microm) eluted with the mobile phases of acetonitrile and 0.1% phosphoric acidwater in gradient mode, the flow rate was 0.25 mL x min(-1) and the detection wavelength was set at 327 nm. Contents of toxicity ingredient: Agilent TC-C18 column (4.6 mm x 250 mm, 5 microm), mobile phase was methanol-0.01 mol x L(-1) sodium dihydrogen phosphate (35: 65), flow rate was 1.0 mL x min(-1), and detection wavelength was 203 nm. The chromatographic fingerprints 16 batches of samples were analyzed in using the similarity evaluation system of chromatographic, fingerprint of traditional Chinese medicine, SPSS16.0 and SIMCA13.0 software, respectively. The similarity degrees of the 16 batches samples were more than 0.97, all the samples were classified into four categories, and the PCA showed that the peak area of chlorogenic acid, 3,5-dicaffeoylquinic acid and caffeic acid were significantly effect index in fingerprint of processed Xanthii Fructus sample. The outcome of determination showed that the toxicity ingredient contents of all samples reduced significantly after processing. This method can be used in optimizing the processing technology of Xanthii Fructus.

  8. Determination of galangin in rat plasma by UPLC and pharmacokinetic study.

    PubMed

    Feng, Wei-hua; Zhang, Hang-hang; Zhang, Yun; Sun, Ming; Niu, Jun-long

    2015-08-15

    In this study, a simple, sensitive, and robust analytical method based on ultra-performance liquid chromatography (UPLC) has been developed for the determination of galangin in rat plasma using diazepam as internal standard (IS). After sample preparation by a simple liquid-liquid extraction, chromatography was performed on an Acquity UPLC BEH C18 column (2.1mm×50mm, 1.7μm particle size) and ultraviolet detection set at a wavelength of 360nm. The method was linear over the concentration range 10-1000ng/mL with a lower limit of quantification (LLOQ) of 10ng/mL. Inter- and intra-day precision (RSD %) were all within 9.5% and the accuracy (RE %) was equal or lower than 8.9%. Recoveries of galangin and IS were more than 78.3%. Stability studies showed that galangin was stable under a variety of storage conditions. The method was successfully applied to a pharmacokinetic study involving oral administration of galangin to rats.

  9. An UPLC-MS/MS method for the quantitation of vortioxetine in rat plasma: Application to a pharmacokinetic study.

    PubMed

    Gu, Er-min; Huang, Chengke; Liang, Bingqing; Yuan, Lingjing; Lan, Tian; Hu, Guoxin; Zhou, Hongyu

    2015-08-01

    In this work, a simple, sensitive and fast ultra performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the quantitative determination of vortioxetine in rat plasma. Plasma samples were processed with a protein precipitation. The separation was achieved by an Acquity UPLC BEH C18 column (2.1mm×50mm, 1.7μm) column with a gradient mobile phase consisting of 0.1% formic acid in water and acetonitrile. Detection was carried out using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The validated method had an excellent linearity in the range of 0.05-20ng/mL (R(2)>0.997) with a lower limit of quantification (0.05ng/mL). The extraction recovery was in the range of 78.3-88.4% for vortioxetine and 80.3% for carbamazepine (internal standard, IS). The intra- and inter-day precision was below 8.5% and accuracy was from -11.2% to 9.5%. No notable matrix effect and astaticism was observed for vortioxetine. The method has been successfully applied to a pharmacokinetic study of vortioxetine in rats for the first time, which provides the basis for the further development and application of vortioxetine.

  10. Sensitive UPLC-MS-MS assay for 21 benzodiazepine drugs and metabolites, zolpidem and zopiclone in serum or plasma.

    PubMed

    Marin, Stephanie J; Roberts, Mark; Wood, Michelle; McMillin, Gwendolyn A

    2012-09-01

    This paper reports an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method to quantitate 21 benzodiazepines, zolpidem and zopiclone in serum and plasma. After liquid-liquid extraction, an Acquity UPLC with a TQ Detector and BEH C18 column was used (Waters, Milford, MA). The injection-to-injection run time was 7.5 min. Forty-eight authentic serum and plasma patient specimens were analyzed and results compared to those obtained using a previously published method. Average r(2) values for linearity (1 to 1,000 ng/mL over five days) were all above 0.995, except α-hydroxytriazolam (0.993). Intra-day and inter-day relative standard deviation values were within ± 15% and the percent deviation from the expected concentrations were within ± 11%. Recovery ranged from 62 to 89%. Matrix effects ranged from -28% to +6%. The limits of detection were 1 ng/mL, except for lorazepam, nordiazepam, oxazepam and temazepam (5 ng/mL). Ion ratios were ± 15% for all analytes. For authentic patient specimens (n = 48, 76 positive results), there was excellent correlation between the UPLC-MS-MS results and the previous method. The best least-squares fit had an equation of y = 1.0708x + 1.6521, r(2) = 0.9822. This UPLC-MS-MS method is suitable for the quantification of benzodiazepines and hypnotics in serum and plasma, and offers fast, reliable and sensitive results.

  11. Stability-indicating UPLC method for determination of Imatinib Mesylate and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms.

    PubMed

    Nageswari, A; Reddy, K V S R Krishna; Mukkanti, K

    2012-07-01

    A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for quantitative determination of purity of Imatinib Mesylate (IMM) drug substance and drug products in the presence of its process related impurities, and degradation products. The proposed RP-UPLC method utilizes Acquity UPLC BEH 50-mm, 2.1mm and 1.7 μm C-18 column at 30 °C, with a gradient program of 9.0 min at a flow rate of 0.3 mL/min. The compounds of interest were monitored at 237 nm. Resolution for Imatinib and eight related components was found to be greater than 1.5 for any pair of components. The correlation coefficients (r(2)>0.9990) obtained indicate clear correlations between the concentrations and their peak areas for the investigated compounds. RSD obtained for the repeatability and intermediate precision experiments, was less than 5.0%. Accuracy of the method was further ascertained by performing recovery studies through spiking experiments. The drug substance was subjected to hydrolytic, oxidative, photolytic and thermal stress conditions as per ICH. The developed method was validated according to the current ICH guidelines for specificity, limit of detection, limit of quantitation, linearity, accuracy, precision, ruggedness and robustness. The method is also suitable for the assay determination of IMM in pharmaceutical dosage forms.

  12. Development and validation of a stability-indicating RP-UPLC method for the quantitative analysis of nabumetone in tablet dosage form.

    PubMed

    Sethi, Neha; Anand, Ankit; Chandrul, Kaushal K; Jain, Garima; Srinivas, Kona S

    2012-02-01

    High efficiency and less run time are the basic requirements of high-speed chromatographic separations. To fulfill these requirements, a new separation technique, ultra-performance liquid chromatography (UPLC), has shown promising developments. A rapid, specific, sensitive, and precise reverse-phase UPLC method is developed for the determination of nabumetone in tablet dosage form. In this work, a new isocratic chromatographic method is developed. The newly developed method is applicable for assay determination of the active pharmaceutical ingredient. The chromatographic separation is achieved on a Waters Acquity BEH column (100 mm, i.d., 2.1 mm, 1.7 µm) within a short runtime of 2 min using a mobile phase of 5 mM ammonium acetate-acetonitrile (25:75, v/v), at a flow rate of 0.3 mL/min at an ambient temperature. Quantification is achieved with photodiode array detection at 230 nm, over the concentration range of 0.05-26 µg/mL. Forced degradation studies are also performed for nabumetone bulk drug samples to demonstrate the stability-indicating power of the UPLC method. Comparison of system performance with conventional high-performance liquid chromatography is made with respect to analysis time, efficiency, and sensitivity. The method is validated according to the ICH guidelines and is applied successfully for the determination of nabumetone in tablets.

  13. Development and Validation of a Stability-Indicating RP-UPLC Method for Determination of Rosuvastatin and Related Substances in Pharmaceutical Dosage Form.

    PubMed

    Trivedi, Harshal Kanubhai; Patel, Mukesh C

    2012-01-01

    A stability-indicating reversed phase ultra performance liquid chromatographic (RP-UPLC) method was developed for the determination of related substances in rosuvastatin calcium (ROSV) tablet dosage form. The chromatographic separation was achieved on an Acquity BEH C18 (100 mm × 2.1 mm, 1.7 μm) column with mobile phase containing a gradient mixture of solvent-A (0.1% trifluoroacetic acid) and solvent-B (methanol). The eluted compounds were monitored at 240 nm and the run time was 10.0 min. Degradation behavior of the ROSV was studied under various degradation stress conditions. Four major unknown degradation products (late eluting impurities) were found in acid stress condition and two unknown degradation products were found in oxidative stress condition. The developed method separates (six) unknown impurities, (three) known impurities and ROSV substance from each other, providing the stability-indicating power of the method. The developed RP-UPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. The developed and validated RP-UPLC method is LC-MS compatible and can be applied for identification of eluted unknown impurities of ROSV.

  14. UPLC-MS/MS determination of phentolamine in human plasma and its application to a pharmacokinetic study.

    PubMed

    Kan, X; Zheng, S-L; Zhou, C-Y

    2014-11-01

    A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine phentolamine in human plasma. Sample preparation was accomplished through a simple liquid-liquid extraction with ethyl acetate. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column using an isocratic mobile phase system composed of acetonitrile and 1% formic acid in water (33:67, v/v) at a flow rate of 0.45 mL/min. Mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 282.1 → 212.0 and m/z 237.1 → 194.2 were used to quantify for phentolamine and carbamazepine (internal standard, IS), respectively. The linearity of this method was found to be within the concentration range of 0.5-100.0 ng/mL with a lower limit of quantification of 0.5 ng/mL. Only 1.0 min was needed for an analytical run. This fully validated method was successfully applied to the pharmacokinetic study after oral administration of 60 mg phentolamine to 20 Chinese healthy male volunteers.

  15. Determination of Sertraline in Human Plasma by UPLC-MS/MS and its Application to a Pharmacokinetic Study.

    PubMed

    Yue, Xiao-Hong; Wang, Zhen; Tian, Dong-Dong; Zhang, Jian-Wei; Zhu, Kang; Ye, Qiang

    2016-02-01

    A sensitive and rapid ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method was developed to determine sertraline in human plasma. Sample preparation was accomplished through a simple liquid-liquid extraction with ethyl acetate. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column using a gradient mobile phase system composed of acetonitrile and 1% formic acid in water at a flow rate of 0.40 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electrospray ionization source in the positive ion mode. The multiple reaction monitoring transitions of m/z 306.3 → 275.2 and 326.2 → 291.1 were used to quantify for sertraline and midazolam (internal standard), respectively. The linearity of this method was found to be within the concentration range of 1.0-100.0 ng/mL with a lower limit of quantification of 1.0 ng/mL. Only 2.0 min was needed for an analytical run. This fully validated method was successfully applied to the pharmacokinetic study after an oral administration of 100 mg sertraline to 20 Chinese healthy male volunteers.

  16. Development and validation of a systematic UPLC-MS/MS method for simultaneous determination of three phenol impurities in ritonavir.

    PubMed

    Venugopal, N; Vijaya Bhaskar Reddy, A; Madhavi, G

    2014-03-01

    A stability indicating gradient reverse phase UPLC-MS/MS method was developed and validated for the simultaneous determination of three phenol impurities in ritonavir drug substance. The chromatographic separation was performed on Acquity UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 μm) using gradient elution of 0.05% ammonia in methanol and 5.0 mM ammonium acetate buffer (30:70, v/v) at a flow rate of 0.2 mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously for the quantification of three phenol impurities. The total run time was 11 min, within which ritonavir and its three impurities were well separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. The calibration curves showed a good linearity over the concentration range of 0.3-1.5 ppm for phenol and 0.1-1.5 ppm for both 4-nitrophenol and N-phenoxycarbonyl-L-valine (NPV). The determination coefficient obtained was >0.9998 in each case. The method had very low limit of detection (LOD) and limit of quantification (LOQ) and the accuracy lies between 97.8% and 103.2% for all the three phenol impurities. The developed method was successfully applied for five formulation batches of ritonavir to determine its phenol impurities.

  17. Rapid determination of eight oxoisoaporphine alkaloids in Rhizoma Menispermi by the optimal homogenate extraction followed by UPLC-MS/MS.

    PubMed

    Wei, Jinxia; Jiang, Zhen; Cui, Zhi; Guo, Xingjie

    2015-07-01

    The objective of this study was to develop a rapid and reliable homogenate extraction (HGE) and ultra high-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method for simultaneous analysis of eight bioactive oxoisoaporphine alkaloids (including two new alkaloids) in Rhizoma Menispermi. HGE was optimized by response surface methodology (RSM) to obtain the maximum extraction efficiency of eight alkaloids. Separation was achieved on a Waters ACQUITY UPLC® BEH C18 column (50 × 2.1 mm(2), 1.7 μm) using gradient elution with a mobile phase consisting of acetonitrile and 0.2% formic acid in water. Quantification was performed with multiple reaction monitoring (MRM) mode using positive ESI as an interface. This is the first report of the simultaneous analysis of eight oxoisoaporphine alkaloids in Rhizoma Menispermi using a UPLC-MS/MS method; this analysis afforded good linearity, precision, and accuracy. Then, the method was successfully applied to determine the alkaloids in Rhizoma Menispermi from different sources.

  18. Force degradation behavior of glucocorticoid deflazacort by UPLC: isolation, identification and characterization of degradant by FTIR, NMR and mass analysis

    PubMed Central

    Deshmukh, Rajesh; Sharma, Lata; Tekade, Muktika; Kesharwani, Prashant; Trivedi, Piyush; Tekade, Rakesh K.

    2016-01-01

    Abstract In this investigation, sensitive and reproducible methods are described for quantitative determination of deflazacort in the presence of its degradation product. The method was based on high performance liquid chromatography of the drug from its degradation product on reverse phase using Acquity UPLC BEH C18 columns (1.7 µm, 2.1 mm × 150 mm) using acetonitrile and water (40:60 V/V) at a flow rate of 0.2 mL/minute in UPLC. UV detection was performed at 240.1 nm. Deflazacort was subjected to oxidative, acid, base, hydrolytic, thermal and photolytic degradation. The drug was found to be stable in water and thermal stress, as well as under neutral stress conditions. However, forced-degradation study performed on deflazacort showed that the drug degraded under alkaline, acid and photolytic stress. The degradation products were well resolved from the main peak, which proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to accuracy, linearity, limit of detection, limit of quantification, accuracy, precision and robustness, selectivity and specificity. Apart from the aforementioned, the results of the present study also emphasize the importance of isolation characterization and identification of degradant. Hence, an attempt was made to identify the degradants in deflazacort. One of the degradation products of deflazacort was isolated and identified by the FTIR, NMR and LC-MS study. PMID:28276670

  19. Subzero-Temperature Liquid-Liquid Extraction Coupled with UPLC-MS-MS for the Simultaneous Determination of 12 Bioactive Components in Traditional Chinese Medicine Gegen-Qinlian Decoction.

    PubMed

    Shi, Zhihong; Li, Zhimin; Zhang, Shulan; Fu, Hongna; Zhang, Hongyi

    2015-09-01

    Based on the phase separation phenomenon of acetonitrile-water system at subzero temperature, a subzero-temperature liquid-liquid extraction coupled with ultra-performance liquid chromatography tandem quadrupole mass spectrometry : UPLC-MS-MS) method was developed for the simultaneous determination of 12 bioactive components in Gegen-Qinlian decoction. After optimization, the extraction conditions were set as follows: 3.0 mL of aqueous sample solution (pH 5.86) was extracted with 2 mL of acetonitrile at -35°C for 35 min. The separated acetonitrile phase was diluted 10-fold with water before UPLC-MS-MS analysis. Separation was performed on a Waters ACQUITY UPLC(®)BEH C18 column (2.1 × 100 mm i.d., 1.7 µm) with ammonium formate buffer solution (20 mmol L(-1), pH 3.2, adjusted by formic acid) and acetonitrile as mobile phase with gradient elution. Twelve target components could be separated within 10 min and quantified in multiple reaction monitoring mode, both positive and negative ionization modes were employed. Limits of detection were in the range of 0.0003-0.0451 μg mL(-1). Relative standard deviation values for intra- and interday precision were <2.71 and 8.94%, respectively. The established method provides a simple and effective framework for the quality control of Gegen-Qinlian decoction and related traditional Chinese medicinal preparations.

  20. SPE-UPLC-MS/MS method for sensitive and rapid determination of aripiprazole in human plasma to support a bioequivalence study.

    PubMed

    Patel, Daxesh P; Sharma, Primal; Sanyal, Mallika; Shrivastav, Pranav S

    2013-04-15

    An improved and rugged UPLC-MS/MS method has been developed and validated for sensitive and rapid determination of aripiprazole in human plasma using aripiprazole-d8 as the internal standard (IS). The analyte and IS were extracted from 100 μL of human plasma by solid-phase extraction using Phenomenex Strata-X (30 mg, 1 cc) cartridges. Chromatography was achieved on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 μm) analytical column using methanol: 10mM ammonium formate (85:15, v/v) as the mobile phase with isocratic elution. Quantitation was done using multiple reaction monitoring in the positive ionization mode. The linearity of the method was established in the concentration range 0.05-80 ng/mL. The mean extraction recovery was greater than 96% across QC levels, while intra- and inter batch accuracy and precision (% CV) values ranged from 97.4 to 101.9% and from 1.20 to 3.72% respectively. The relative matrix effect in eight different lots of plasma samples, expressed as % CV for the calculated slopes of calibration curves was 1.08%. The stability of aripiprazole was studied under different storage conditions. The validated method was used to support a bioequivalence study of 10mg aripiprazole formulation in 36 healthy Indian subjects.

  1. Development and validation of sensitive and rapid UPLC-MS/MS method for quantitative determination of daclatasvir in human plasma: Application to a bioequivalence study.

    PubMed

    Rezk, Mamdouh R; Bendas, Ehab R; Basalious, Emad B; Karim, Iman A

    2016-09-05

    A rapid and sensitive UPLC-MS/MS method was developed and validated for determination of daclatasvir (DAC) in human plasma using sofosbuvir (SOF) as an internal standard (IS). The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Precipitation with acetonitrile was used in sample preparation. The prepared samples were chromatographed on Acquity UPLC HSS C18 (50×2.1mm, 1.8μm) column by pumping 10mM ammonium formate (pH 3.5) and acetonitrile in an isocratic mode at a flow rate of 0.30ml/min. Method validation was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 5-4000ng/ml for DAC. The intra-day and inter-day precision and accuracy results were within the acceptable limits. A very short run time of 1.2min made it possible to analyze more than 500 human plasma samples per day. The wider range of quantification of DAC allowed the applicability of the developed method for its determination in a bioequivalence study in human volunteers.

  2. Development and Validation of an UPLC-Q-TOF-MS Method for Quantification of Fuziline in Beagle Dog After Intragastric and Intravenous Administration.

    PubMed

    Gong, Xiao-hong; Li, Yan; Li, Yun-xia; Yuan, An; Zhao, Meng-jie; Zhang, Ruo-qi; Zeng, Dai-wen; Peng, Cheng

    2016-03-01

    A specific and sensitive UPLC-Q-TOF-MS method operated in the positive ion mode was developed and validated for the quantification of Fuziline in Beagle dog plasma. Fuziline and Neoline internal standard were separated on an Acquity UPLC BEH C18 column with the total running time of 4 min using gradient elution at the flow rate of 0.25 mL/min. The calibration curves for Fuziline showed good linearity in the concentrations ranging from 2 to 400 ng/mL with correlation coefficients (r) greater than 0.9971. The lower limit of quantification was 0.8 ng/mL. Intra- and interbatch relative standard deviations ranged from 2.11 to 3.11% and 3.12 to 3.81%, respectively. Fuziline was stable under different sample storage and processing conditions. The developed method was successfully applied to the comparative pharmacokinetic study of Fuziline in Beagle dog after intravenous and oral administration. Low absolute bioavailability of Fuziline (1.45 ± 0.76%) suggested a significant metabolism transformation extent in Beagle dog.

  3. Quantification of carbamazepine and its 10,11-epoxide metabolite in rat plasma by UPLC-UV and application to pharmacokinetic study.

    PubMed

    Beig, Avital; Dahan, Arik

    2014-07-01

    A rapid, selective and sensitive UPLC-UV method was developed and validated for the quantitative analysis of carbamazepine and its epoxide metabolite in rat plasma. A relatively small volume of plasma sample (200 μL) is required for the described analytical method. The method includes simple protein precipitation, liquid-liquid extraction, evaporation, and reconstitution steps. Samples were separated on a Waters Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 100 mm) with a gradient mobile phase consisted of 60:40 going to 40:60 (v/v) water-acetonitrile at a flow rate of 0.5 mL/min. The total run time was as low as 6 min, representing a significant improvement in comparison to existing methods. Excellent linearity (r(2)  > 0.999) was achieved over a wide concentration range. Close to complete recovery, short analysis time, high stability, accuracy, precision and reproducibility, and low limit of quantitation were demonstrated. Finally, we successfully applied this analytical method to a pre-clinical oral pharmacokinetic study, revealing the plasma profiles of both carbamazepine and carbamazepine-10,11-epoxide following oral administration of carbamazepine to rats. The advantages demonstrated in this work make this analytical method both time- and cost-efficient approach for drug and metabolite monitoring in the pre-clinical/clinical laboratory.

  4. A novel reverse phase stability indicating RP-UPLC method for the quantitative determination of fifteen related substances in Ranolazine drug substance and drug product.

    PubMed

    Malati, Vakamulla; Reddy, Anumala Raghupati; Mukkanti, K; Suryanarayana, M V

    2012-08-15

    A gradient reverse-phase ultra performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of Ranolazine and potential process-related impurities (starting materials, positional isomers, degradants and byproducts) at the level of 0.1 μg mL(-1) to 0.3 μg mL(-1). Fifteen potential impurities were identified in the crude samples during the process development. Tentative structures for all the impurities were assigned based on m/z values from LC-MS/MS analysis. This method can be used for the quality control of both drug substance and drug product. All these impurities were separated with a gradient UPLC method by using a polar embedded Waters Acquity BEH RP18 100 mm × 2.1 mm,1.7 μm column, monobasic sodium buffer, a basic organic modifier and acetonitrile in the mobile phase. Further, this method is also capable of separating a major oxidative degradant Di-N-oxide. Impurities having electron donating groups(+I effect) on the phenyl ring increased the retention by improved п-п interactions. The drug was subjected to the International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness.

  5. Simultaneous Determination of Typhaneoside and Isorhamnetin-3-O-Neohesperidoside in Rats After Oral Administration of Pollen Typhae Extract by UPLC-MS/MS.

    PubMed

    Cao, Sali; Ni, Boran; Feng, Lijun; Yin, Xingbin; Dou, Haoran; Fu, Jing; Lin, Longfei; Ni, Jian

    2015-07-01

    For the first time, a selective and rapid ultra-performance liquid chromatography method with tandem mass spectrometric (UPLC-MS/MS) detection for simultaneous determination of typhaneoside and isorhamnetin-3-O-neohesperidoside in rat plasma was developed and validated, which was applied to the pharmacokinetic study of Pollen Typhae extract. The separation was carried out on an ACQUITY UPLC(TM) BEH C18 column with gradient elution using mobile phase including acetonitrile and water (containing 0.1% formic acid). The flow rate was 0.4 mL/min. The detection was conducted by means of electrospray ionization mass spectrometry in negative ion mode with multiple reaction monitoring. The assays were linear over the concentration range of 0.5-100 ng/mL, and the lower limit of quantification was 0.5 ng/mL for typhaneoside and isorhamnetin-3-O-neohesperidoside. The method was validated in terms of intra- and interday precision (<9.37%), accuracy (within ±10.91%), linearity, specificity and stability, and has been successfully applied to a pharmacokinetic study of Pollen Typhae extract in rats after oral administration.

  6. Complete temperature profiles in ultra-high-pressure liquid chromatography columns.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-07-01

    The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C 18 particles, average d(p) approximately 1.7 microm) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than +/-0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.

  7. Determination of N-nitrosodiethanolamine, NDELA in cosmetic ingredients and products by mixed mode solid phase extraction and UPLC-tandem mass spectrometry with porous graphitic carbon column through systemic sample pre-cleanup procedure.

    PubMed

    Joo, Kyung-Mi; Shin, Mi-Sook; Jung, Ji-hee; Kim, Boo-Min; Lee, John-Whan; Jeong, Hye-Jin; Lim, Kyung-Min

    2015-05-01

    A rapid, sensitive, accurate and specific ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) method for the detection of N-nitrosodiethanolamine (NDELA), a highly toxic contaminant in cosmetic raw materials and products was developed and validated. Systematized sample preparation steps were developed according to product types. Various SPE cartridges and columns were examined to establish the condition of SPE and chromatographic separation for NDELA. Sample cleanup steps consisting of solvent and liquid-liquid extraction tailored to the various sample matrix types were established prior to mixed mode SPE (Bond Elut AccuCAT). Chromatographic separation was achieved within 7 min on a porous graphitic carbon (PGC) column using a gradient elution with the mobile phase of 1mM ammonium acetate containing 0.1% acetic acid and methanol. NDELA was monitored using an electrospray positive ionization mass spectrometry in the multiple reaction monitoring (MRM) mode (m/z 134.9>103.7(quantifier) and 73.7(qualifier ion)) with d8-NDELA (m/z 143.1>111.0) as internal standard. The standard curves were linear over the concentration range of 1-100 ng/mL with a correlation coefficient higher than 0.99. The limit of detection (LOD) and the limit of quantification (LOQ) was 10 and 20 μg/kg, respectively (0.5 and 1 ng/mL in standard solution). The intra- and inter-day precisions were estimated to be below 11.1% and accuracies were within the range of 90.8-115.8%. The validated method was successfully applied to the analysis of real samples including raw materials, skin care, make-up, shampoos and hair products.

  8. UPLC-MS/MS assay for the simultaneous determination of ethinyl estradiol, norgestimate and 17-Desacetyl norgestimate at low pg/mL in human plasma.

    PubMed

    Huang, Mike-Qingtao; Kang, Lijuan; Wang, Weimin; Skee, Donna; Chen, Mu; Lin, Zhongping John; Verhaeghe, Tom; Weng, Naidong

    2016-04-01

    Previously, because of the difficulty of measuring very low levels (pg/mL) of norgestimate (NGM) due to rapid metabolism to its active and major metabolite, 17-Desacetyl norgestimate (DNGM), only DNGM and the co-administered ethinyl estradiol (EE2) were required to be analyzed in bioequivalence (BE) studies for oral contraceptive NGM/EE2 tablets. Recently, with more sensitive assays available, health authorities have requested that bioequivalence of NGM be also demonstrated in addition to DNGM and EE2. Therefore, it was important to establish a 3-in-1 method for the quantitation of EE2, NGM and DNGM in human plasma. Here a UPLC-MS/MS method for the simultaneous quantitation of EE2, NGM and DNGM in human plasma at low pg/mL range is described. EE2, NGM, DNGM and their isotopic labeled internal standards (IS) EE2-d4, NGM-d6 and DNGM-d6 in 0.4mL of human plasma were extracted with hexane/ethyl acetate. The extracts were evaporated to dryness and derivatized with dansyl chloride, to enhance the mass spec response. The derivatives were reconstituted with methanol and analyzed by UPLC-MS/MS. In order to minimize the ex-vivo conversion of NGM to DNGM, sodium fluoride/potassium oxalate was used as anti-coagulant. To achieve desirable throughput for sample analysis, UPLC-MS/MS with a run time of 4.4min was utilized. The calibration curve ranges were 5-500pg/mL for EE2 and NGM, and 25-2500pg/mL for DNGM, respectively. The chromatographic separation was achieved on a Waters Acquity UPLC HSS T3 (100×2.1mm, 1.8μm) column with a gradient elution. Assay accuracy, precision, linearity, selectivity, sensitivity and analyte stability covering sample storage and analysis were established. This validated UPLC-MS/MS method has been applied to a BE study for the determination of EE2, NGM and DNGM concentrations in human plasma.

  9. Automatic and rapid identification of glycopeptides by nano-UPLC-LTQ-FT-MS and proteomic search engine.

    PubMed

    Giménez, Estela; Gay, Marina; Vilaseca, Marta

    2017-01-30

    Here we demonstrate the potential of nano-UPLC-LTQ-FT-MS and the Byonic™ proteomic search engine for the separation, detection, and identification of N- and O-glycopeptide glycoforms in standard glycoproteins. The use of a BEH C18 nanoACQUITY column allowed the separation of the glycopeptides present in the glycoprotein digest and a baseline-resolution of the glycoforms of the same glycopeptide on the basis of the number of sialic acids. Moreover, we evaluated several acquisition strategies in order to improve the detection and characterization of glycopeptide glycoforms with the maximum number of identification percentages. The proposed strategy is simple to set up with the technology platforms commonly used in proteomic labs. The method allows the straightforward and rapid obtention of a general glycosylated map of a given protein, including glycosites and their corresponding glycosylated structures. The MS strategy selected in this work, based on a gas phase fractionation approach, led to 136 unique peptides from four standard proteins, which represented 78% of the total number of peptides identified. Moreover, the method does not require an extra glycopeptide enrichment step, thus preventing the bias that this step could cause towards certain glycopeptide species. Data are available via ProteomeXchange with identifier PXD003578.

  10. Development and validation of UPLC-MS/MS method for simultaneous determination of gestodene and ethinyl estradiol in rat plasma.

    PubMed

    Xiong, Zhili; Sun, Xiaohong; Huo, Taoguang; Li, Ning; Zheng, Yan; Sun, Yi

    2010-02-01

    A selective and sensitive ultra-performance liquid chromatography method with tandem mass spectrometric detection for simultaneous determination of gestodene (GES) and ethinyl estradiol (EE) in rat plasma was developed and validated. GES, EE and the internal standard, norgestrel, were extracted with ethyl acetate, derivatized (EE only) with dansyl chloride and then back-extracted into diethyl ether-hexane (2:1, v/v). The separation was performed on an ACQUITY UPLC BEH C(18) column with gradient elution using mobile phase consisting of acetonitrile and water (both containing 0.1% formic acid). The detection was carried out by means of electrospray ionization (ESI) mass spectrometry in positive ion mode with multiple-reaction monitoring. Calibration curves of GES and EE were linear (r(2) >or= 0.99) over the concentration ranges 1.59-159 and 0.196-78.4 ng/mL, respectively. The intra- and inter-day precisions were not more than 6.9 and 12.9% for GES and 10.6 and 9.0% for EE, and the accuracies were -2.5-8.0% for GES, and -7.2-0.19% for EE, respectively. The method herein described was superior to previous methods and was applicable to the pharmacokinetic study of GES and EE in rats.

  11. Novel and sensitive UPLC-MS/MS method for quantification of sofosbuvir in human plasma: application to a bioequivalence study.

    PubMed

    Rezk, Mamdouh R; Basalious, Emad B; Amin, Mohammed E

    2016-09-01

    A novel and sensitive LC-MS/MS method was developed and validated for determination of sofosbuvir (SF) using eplerenone as an internal standard. The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Extraction with tert-butyl methyl ether was used in sample preparation. The prepared samples were chromatographed on Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 μm) column by pumping 0.1% formic acid and acetonitrile in an isocratic mode at a flow rate of 0.35 mL/min. Method validation was performed as per the US Food and Drug Administration guidelines and the standard curves were found to be linear in the range of 0.25-3500 ng/mL for SF. The intra- and inter-day precision and accuracy results were within the acceptable limits. A very short run time of 1 min made it possible to analyze more than 500 human plasma samples per day. A very low quantification limit of SF allowed the applicability of the developed method for determination of SF in a bioequivalence study in human volunteers. Copyright © 2016 John Wiley & Sons, Ltd.

  12. Definitive Drug and Metabolite Screening in Urine by UPLC-MS-MS Using a Novel Calibration Technique.

    PubMed

    Rosano, Thomas G; Ohouo, Patrice Y; LeQue, John J; Freeto, Scott M; Wood, Michelle

    2016-10-01

    Drug screening is an essential analytical tool for detection of therapeutic, illicit and emerging drug use. Presumptive immunoassay screening is widely used, while initial definitive testing by chromatography-coupled mass spectrometry is hampered due to complex pre-analysis steps, long chromatography time and matrix effects. The aim of this study is to develop and validate a definitive test for rapid and threshold accurate screening of 33 drugs or metabolites (analytes) in urine. Sample preparation in a 96-well plate format involves rapid glucuronidase hydrolysis followed by dilution, filtration and ultra-performance liquid chromatography-MS-MS analysis. Chromatographic separation, on an ACQUITY UPLC(®) BEH phenyl column is optimized for a 3-min MS-MS ion acquisition. Matrix effect was normalized by an innovative technique called threshold accurate calibration employing an additional analysis with an analyte spike as an internal standard undergoing the same matrix effect as an analyte in a drug-positive donor specimen. Accuracy and precision, at above and below threshold concentrations, were determined by replicate analysis of control urine pools containing 50, 75, 125 and 150% of threshold concentrations. Accuracy and selectivity were further demonstrated by concordant findings in proficiency and confirmatory testing. The study shows the applicability of definitive testing as an alternative to immunoassay screening and demonstrates a new approach to normalization of matrix effect.

  13. Automated liquid-liquid extraction based on 96-well plate format in conjunction with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the quantitation of methoxsalen in human plasma.

    PubMed

    Yadav, Manish; Contractor, Pritesh; Upadhyay, Vivek; Gupta, Ajay; Guttikar, Swati; Singhal, Puran; Goswami, Sailendra; Shrivastav, Pranav S

    2008-09-01

    A sensitive, specific and high throughput bioanalytical method using automated sample processing via 96-well plate liquid-liquid extraction and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of methoxsalen in human plasma. Plasma samples with ketoconazole as internal standard (IS) were prepared by employing 0.2 mL human plasma in ethyl acetate:dichloromethane (80:20, v/v). The chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 column using isocratic mobile phase, consisting of 10 mM ammonium formate and acetonitrile (60:40, v/v), at a flow rate of 0.5 mL/min. The linear dynamic range was established over the concentration range 1.1-213.1 ng/mL for methoxsalen. The method was rugged and rapid with a total run time of 1.5 min. It was successfully applied to a pivotal bioequivalence study in 12 healthy human subjects after oral administration of 10 mg extended release methoxsalen formulation under fasting condition.

  14. Development of a Stability-Indicating RP-UPLC Method for Rapid Determination of Metaxalone and its Degradation Products in Solid Oral Dosage Form

    PubMed Central

    Trivedi, Rakshit Kanubhai; Patel, Mukesh C.

    2012-01-01

    A simple, sensitive and reproducible reversed phase ultra performance liquid chromatography (RP-UPLC) coupled with a photodiode array detector method was developed for the quantitative determination of metaxalone (META) in pharmaceutical dosage forms. The method is applicable to the quantification of related substances and assay of drug product. Chromatographic separation was achieved on an Acquity® HSS-T3 (100 mm x 2.1 mm, 1.7 μm) column. The optimized isocratic mobile phase consists of a mixture of water, methanol, acetonitrile and triethylamine in the ratio of 50:25:25:0.1 % v/v (pH adjusted to 6.3 with orthophosphoric acid). The eluted compounds were monitored at 230 nm for META assay and 205 nm for related substances, the flow rate was 0.3 mL/min, and the column oven temperature was maintained at 45°C. The developed method separated META from its two known and two unknown impurities within 6.0 min. Metaxalone was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Metaxalone was found to degrade significantly in base stress condition, degrade slightly in oxidative stress condition and remain stable in acid, hydrolytic, thermal and photolytic degradation conditions. All impurities were well resolved from each other and from the main peak, showing the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH) guidelines. PMID:22896822

  15. Development of a stability-indicating UPLC method for determining olanzapine and its associated degradation products present in active pharmaceutical ingredients and pharmaceutical dosage forms.

    PubMed

    Krishnaiah, Ch; Vishnu Murthy, M; Kumar, Ramesh; Mukkanti, K

    2011-03-25

    A simple, sensitive and reproducible ultra performance liquid chromatography (UPLC) coupled with a photodiode array detector method was developed for the quantitative determination of olanzapine (OLN) in API and pharmaceutical dosage forms. The method is applicable to the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH 100-mm, 2.1-mm, and 1.7-μm C-18 columns, and the gradient eluted within a short runtime, i.e., within 10.0 min. The eluted compounds were monitored at 250 nm, the flow rate was 0.3 mL/min, and the column oven temperature was maintained at 27°C. The resolution of OLN and eight (potential, bi-products and degradation) impurities was greater than 2.0 for all pairs of components. The high correlation coefficient (r(2)>0.9991) values indicated clear correlations between the investigated compound concentrations and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the RSD, were less than 2.4%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method expressed as relative error was satisfactory. No interference was observed from concomitant substances normally added to the tablets. The drug was subjected to the International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness.

  16. Analysis of 21-hydroxy deflazacort in human plasma by UPLC-MS/MS: application to a bioequivalence study in healthy volunteers.

    PubMed

    Patel, Daxesh P; Sharma, Primal; Patel, Bhargav M; Sanyal, Mallika; Singhal, Puran; Shrivastav, Pranav S

    2013-11-01

    A sensitive and rapid ultra performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method has been developed for the determination of 21-hydroxy deflazacort in human plasma using betamethasone as the internal standard (IS). After solid-phase extraction from 100 μL human plasma, the analyte and IS were analyzed on Waters Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 μm) column using acetonitrile-4.0mM ammonium formate, pH 3.5 (90:10, v/v) as the mobile phase. The protonated analyte was quantified by selected reaction monitoring in the positive ionization mode by triple quadrupole mass spectrometer. The calibration plots were linear over the concentration range 0.50-500 ng/mL. Intra-batch and inter-batch precision (% CV) and accuracy (%) for five quality control samples ranged within 1.40-4.82% and 98.0-102.0% respectively. The overall mean extraction recovery of 21-hydroxy deflazacort from plasma ranged from 95.3 to 97.3%. Matrix effect was assessed by post-column analyte infusion and the extraction recovery was >95.0% across four quality control levels for the analyte and IS. Stability was evaluated under different conditions like bench top, autosampler, processed sample (at room temperature and in cooling chamber), freeze-thaw and long term stability. The method was applied to support a bioequivalence study of 30 mg deflazacort tablet formulation in 28 healthy subjects. Assay reproducibility was demonstrated by reanalysis of 115 incurred samples.

  17. Application of a UPLC-MS/MS method for the analysis of alosetron in human plasma to support a bioequivalence study in healthy males and females.

    PubMed

    Chaudhary, Darshan V; Patel, Daxesh P; Shah, Jaivik V; Shah, Priyanka A; Sanyal, Mallika; Shrivastav, Pranav S

    2015-10-01

    A simple, rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the determination of alosetron (ALO) in human plasma. The assay method involved solid-phase extraction of ALO and ALO 13C-d3 as internal standard (IS) on a LichroSep DVB-HL (30 mg, 1 cm(3) ) cartridge. The chromatography was performed on an Acquity UPLC BEH C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile and 2.0 mm ammonium formate, pH 3.0 adjusted with 0.1% formic acid (80:20, v/v) as the mobile phase in an isocratic mode. For quantitative analysis, the multiple reaction monitoring transitions studied were m/z 295.1/201.0 for ALO and m/z 299.1/205.1 for IS in the positive ionization mode. The method was validated over a concentration range of 0.01-10.0 ng/mL for ALO. Post-column infusion experiment showed no positive or negative peaks in the elution range of the analyte and IS after injection of extracted blank plasma. The extent of ion-suppression/enhancement, expressed as IS-normalized matrix factor, varied from 0.96 to 1.04. The assay recovery was within 97-103% for ALO and IS. The method was successfully applied to support a bioequivalence study of 1.0 mg alosetron tablets in 28 healthy Indian male and female subjects.

  18. A UPLC/MS/MS method for determination of protosappanin B in rat plasma and its application of a pharmacokinetic and bioavailability study.

    PubMed

    Chen, Wei-Ying; Zhou, Xian-Zhen; Wu, Li-Lan; Wu, Yun-Shan; Wang, Shu-Mei; Liu, Bo; Guo, De-An

    2016-12-14

    Caesalpinia sappan L. is a traditional medicinal plant which is used for promoting blood circulation and cerebral apoplexy therapy in China. Previous reports showed that the extracts of Caesalpinia sappan L. could exert vasorelaxant activity and anti-inflammation activity. Protosappanin B is a major constituent of C. sappan L., and showed several important bioactivities. The separation was achieved by an Acquity UPLC BEH Symmetry Shield RP18 column (1.7 μm, 2.1 × 100 mm) column with the gradient mobile phase consisting of 5 mm ammonium acetate aqueous solution and acetonitrile. Detection was carried out by using negative-ion electrospray tandem mass spectrometry via multiple reaction monitoring. Plasma samples were preprocessed by an extraction with ethyl acetate, and apigenin was used as internal standard. The current UPLC-MS/MS assay was validated for linearity, accuracy, intraday and interday precisions, stability, matrix effects and extraction recovery. After oral and intravenous administration, the main pharmacokinetic parameters were as follows: peak concentrations, 83.5 ± 46.2 and 1329.6 ± 343.6 ng/mL; areas under the concentration-time curve, 161.9 ± 69.7 and 264.9 ± 56.3 μg h/L; and half-lives, 3.4 ± 0.9 and 0.3 ± 0.1 h, respectively. The absolute bioavailability in rats of protosappanin B was 12.2%. The method has been successfully applied to a pharmacokinetic and bioavailability study of protosappanin B in rats.

  19. Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.

    PubMed

    Gritti, Fabrice; Guiochon, Georges

    2008-04-11

    The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in

  20. Development and validation of a selective, sensitive and stability indicating UPLC-MS/MS method for rapid, simultaneous determination of six process related impurities in darunavir drug substance.

    PubMed

    A, Vijaya Bhaskar Reddy; Yusop, Zulkifli; Jaafar, Jafariah; Aris, Azmi B; Majid, Zaiton A; Umar, Khalid; Talib, Juhaizah

    2016-09-05

    In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis.

  1. Simultaneous determination of ledipasvir, sofosbuvir and its metabolite in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Pan, Chenwei; Chen, Yongping; Chen, Weilai; Zhou, Guangyao; Jin, Lingxiang; Zheng, Yi; Lin, Wei; Pan, Zhenzhen

    2016-01-01

    In this work, a rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the determination of ledipasvir, sofosbuvir and its metabolite GS-331007 in rat plasma was developed. The analytes and the internal standard (diazepam) were separated on an Acquity UPLC BEH C18 chromatography column (2.1mm×50mm, 1.7μm) using gradient elution with a mobile phase of acetonitrile and 0.1% formic acid in water at a flow rate of 0.4mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode to monitor the precursor-to-product ion transitions of m/z 889.8→130.1 for ledipasvir, m/z 530.3→243.1 for sofosbuvir, m/z 261.5→113.1 for GS-331007 and m/z 285.2→193.1 for diazepam (IS) using a positive electrospray ionization interface. The method was validated over a concentration range of 2-500ng/mL for ledipasvir, 10-2000ng/mL for sofosbuvir and 10-2000ng/mL for GS-331007. Total time for each chromatography was 3.0min. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD)<10.2% and the accuracy values ranged from -9.8% to 11.2%. The method was successfully applied to a pharmacokinetic study of ledipasvir, sofosbuvir and GS-331007 in rats.

  2. Simultaneous quantification of vortioxetine, carvedilol and its active metabolite 4-hydroxyphenyl carvedilol in rat plasma by UPLC-MS/MS: Application to their pharmacokinetic interaction study.

    PubMed

    Huang, Yi; Zheng, Shuangli; Pan, Yongyang; Li, Tao; Xu, Zhi-Sheng; Shao, Meng-Meng

    2016-09-05

    To establish a rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the determination of vortioxetine, carvedilol and its metabolite 4-hydroxyphenyl carvedilol in rat plasma. The analytes and the internal standard (diazepam) were separated on an Acquity UPLC BEH C18 chromatography column (2.1mm×50mm, 1.7μm) using gradient elution with a mobile phase of acetonitrile and 0.1% formic acid in water at a flow rate of 0.4mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode to monitor the precursor-to-product ion transitions of m/z 299.2→150.1 for vortioxetine, m/z 407.2→100.3 for carvedilol, m/z 423.2→100.1 for 4-hydroxyphenyl carvedilol and m/z 285.2→193.1 for diazepam (IS) using a positive electrospray ionization interface. The method was validated over a concentration range of 0.5-100ng/mL for vortioxetine, 0.5-1000ng/mL for carvedilol and 0.1-50ng/mL for 4-hydroxyphenyl carvedilol. Total time for each chromatograph was 3.0min. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD)<11.6% and the accuracy values ranged from -12.2% to 11.3%. The analytical method was successfully applied to a pharmacokinetic interaction study of vortioxetine and carvedilol after oral administration vortioxetine and carvedilol in rats. Results suggested that the co-administration of vortioxetine and carvedilol results in a significant drug interaction in rats.

  3. Development and Validation of a Rapid RP-UPLC Method for the Simultaneous Estimation of Bambuterol Hydrochloride and Montelukast Sodium from Tablets

    PubMed Central

    Yanamandra, R.; Vadla, C. S.; Puppala, U. M.; Patro, B.; Murthy, Y. L. N.; Parimi, A. R.

    2012-01-01

    A rapid, simple, sensitive and selective analytical method was developed by using reverse phase ultra performance liquid chromatographic technique for the simultaneous estimation of bambuterol hydrochloride and montelukast sodium in combined tablet dosage form. The developed method is superior in technology to conventional high performance liquid chromatography with respect to speed, resolution, solvent consumption, time, and cost of analysis. Elution time for the separation was 6 min and ultra violet detection was carried out at 210 nm. Efficient separation was achieved on BEH C18 sub-2-μm Acquity UPLC column using 0.025% (v/v) trifluoro acetic acid in water and acetonitrile as organic solvent in a linear gradient program. Resolutions between bambuterol hydrochloride and montelukast sodium were found to be more than 31. The active pharmaceutical ingredient was extracted from tablet dosage from using a mixture of methanol, acetonitrile and water as diluent. The calibration graphs were linear for bambuterol hydrochloride and montelukast sodium in the range of 6.25-37.5 μg/ml. The percentage recoveries for bambuterol hydrochloride and montelukast sodium were found to be in the range of 99.1-100.0% and 98.0-101.6%, respectively. The test solution was found to be stable for 7 days when stored in the refrigerator between 2-8°. Developed UPLC method was validated as per International Conference on Harmonization specifications for method validation. This method can be successfully employed for simultaneous estimation of bambuterol hydrochloride and montelukast sodium in bulk drugs and formulations. PMID:23325991

  4. Stability-Indicating UPLC Method for Tramadol HCl Impurities in the Tramadol Injection after Dilution by Infusion Fluids (5% Dextrose and 0.9% Sodium Chloride).

    PubMed

    Binnor, Anil K; Mukkanti, Khagga; Suryanarayana, Mulukutla V; Roy, Sunilendu B

    2013-01-01

    A novel, rapid, and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated as per ICH guidelines for the determination of tramadol HCl impurities in the tramadol HCl injection after reconstitution by infusion fluids (5% dextrose and 0.9% sodium chloride). The tramadol HCl injection is for the treatment of patients with moderate-to-severe pain. The stability of the reconstituted solution is critical before intravenous injection. The literature search resulted in few published articles on assays of tramadol in infusion fluids by conventional HPLC. No attempts have yet been made to determine the impurities in infusion fluids, as the concentration of tramadol after reconstitution is extremely low (0.4 mg/mL) and that of impurities is even lower. The proposed method is novel as it allows the quantitation of the impurities of tramadol HCl and is based on modern chromatographic techniques like UPLC. The method was developed using the Waters Acquity BEH C18 column with a mobile phase consisting of a gradient mixture of solvent A (trifluroacetic acid buffer) and solvent B (methanol: acetonitrile). The model stability study was designed by diluting the tramadol HCl injection in the 5% dextrose injection and 0.9% sodium chloride injection. Each mixture was kept under storage at room temperature (25 ± 2°C) for testing at initial, 2, 4, 8, 12, 18 & 24 hours. The validation study illustrates that the proposed method is suitable for the determination of tramadol and its impurities. The proposed method makes use of the LC-MS-compatible mobile phase. It can be useful for the determination of tramadol HCl and its impurities in plasma samples and other pharmaceutical dosage forms.

  5. Clenbuterol determination in calf hair by UPLC-MS-MS: case report of a fraudulent use for cattle growth.

    PubMed

    Salquèbre, Guillaume; Bresson, Marie; Villain, Marion; Cirimele, Vincent; Kintz, Pascal

    2007-03-01

    A method for clenbuterol determination in hair has been developed. Hair specimens collected from two calves were decontaminated using hot water followed by methylene chloride. Hair was cut into small pieces, and 100 mg was incubated in 1 mL 0.1M hydrochloric acid overnight at 45 degrees C in the presence of 1 ng acebutolol used as internal standard. After neutralization with 1 mL 0.1M NaOH, 2 mL of bicarbonate buffer (pH 8.6) were added and the preparation was then purified using solid-phase extraction with an Isolute C18 column. Methanolic eluent was evaporated to dryness and the residue was reconstituted with 50 microL methanol. A 5-microL portion was injected onto an ACQUITY UPLC BEH C18 column (2.1 x 50 mm, 1.7 microm) and separation was achieved using a gradient of acetonitrile and formate buffer delivered at a flow rate of 0.6 mL/min. Detection was done on a Waters Micromass Quattro Micro API triple-quadrupole mass spectrometer. Ionization was achieved using electrospray in positive mode. Clenbuterol was identified by two transitions (m/z 277.1 > 203.2 and m/z 277.1 > 132.1). Quantitation was performed with the most intensive transition (m/z 277.1 > 203.2) versus the internal standard monitored using the transition (m/z 337.3 > 116.1). When compared with gas chromatography methods that are generally used for the determination of beta-adrenergics, the major advantages of this method were the sensitivity, a shorter run time, and the absence of a derivatization step. The analysis of two hair samples from calves suspected of drug administration showed low clenbuterol concentrations at 3.6 and 4.8 pg/mg.

  6. Development of a sensitive UPLC-ESI-MS/MS method for quantification of sofosbuvir and its metabolite, GS-331007, in human plasma: Application to a bioequivalence study.

    PubMed

    Rezk, Mamdouh R; Basalious, Emad B; Karim, Iman A

    2015-10-10

    A rapid and simple LC-MS/MS method was developed and validated for the simultaneous estimation of sofosbuvir (SF) and its metabolite GS-331007 (GS) using famotidine as an internal standard (IS). The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Extraction with ethyl acetate was used in sample preparation. The prepared samples were chromatographed on Acquity UPLC HSS C₁₈ (50 mm × 2.1 mm, 1.8 μm) column by pumping 0.1% formic acid and acetonitrile (50:50, v/v) in an isocratic mode at a flow rate of 0.3 ml/min. Method validation was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 10-2500 ng/ml for both SF and its metabolite. The intra-day and inter-day precision and accuracy results were within the acceptable limits. A very short run time of 1.2 min made it possible to analyze more than 300 human plasma samples per day. The developed assay method was successfully applied to a bioequivalence study in human volunteers.

  7. Development and Validation of a New Stability-Indicating RP-UPLC Method for the Quantitative Determination of Bromfenac Sodium and Its Impurities in an Ophthalmic Dosage Form.

    PubMed

    Koppala, Srinivasarao; Reddy, V Ranga; Anireddy, Jaya Shree

    2016-06-06

    A new rapid stability-indicating reversed-phase UPLC method was developed and validated for the determination of Bromfenac sodium and its impurities in Bromfenac ophthalmic solution. During literature search, only a few publications were found about Bromfenac sodium. There is no official monograph in the pharmacopoeias about Bromfenac sodium. Chromatographic separation has been achieved on a polar-embedded Waters Acquity BEH Shield RP18 (100 mm × 2.1 mm, 1.7 μm) column under gradient elution by using a binary mixture of potassium dihydrogen phosphate (0.01 M, pH 3.3) and acetonitrile (ACN) at a flow rate of 0.5 mL/min. Chromatogram was monitored at 265 nm using a photodiode array detector (PDA). The drug and its related impurities are eluted within 13 min. Resolution of Bromfenac sodium and all eight potential impurities have been achieved greater than 4.0 for all pairs of compounds. To prove the stability-indicating power of the method, the drug was subjected to hydrolytic (acid, alkaline and water), oxidative, photolytic and thermal stress, and the major degradation products were identified based on LC-MS analysis. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, precision, accuracy and robustness.

  8. Validation of an UPLC-MS-MS Method for Quantitative Analysis of Vincristine in Human Urine After Intravenous Administration of Vincristine Sulfate Liposome Injection.

    PubMed

    Yang, Fen; Wang, Hongyun; Hu, Pei; Jiang, Ji

    2015-07-01

    Vincristine sulfate liposome injection (VSLI) is a liposomal formulation of vincristine (VCR) sulfate, being developed for the systemic treatment of cancer. In this paper, we have developed and validated a method to quantify VCR in human urine to obtain the urinary excretion of VCR after intravenous administration of VSLI. The analyte was extracted from urine samples using liquid-liquid extraction after addition of vinblastine (VBL, used as internal standard) and chromatographed on an Acquity UPLC HSS T3 column with a gradient mobile phase at a flow rate of 0.4 mL/min. The multiple reactions monitoring transitions of m/z 413.2 → 353.2 and m/z 406.2 → 271.6 were used to quantify VCR and VBL, respectively. The lower limit of quantification was 0.5 ng/mL with a precision (RSD%) of 5.7% and an accuracy (RE%) of 6.7%. The calibration curve was linear up to 100.0 ng/mL. Intraday precision and accuracy ranged from 0.8 to 11.0% and from -12.4 to 11.3%, respectively. Interassay precision and accuracy ranged from 8.0 to 10.1% and from -7.7 to 3.6%, respectively. No significant matrix effect was observed for VCR. The method was successfully applied for pharmacokinetic study of VSLI to investigate the route and extent of VCR urinary excretion in Chinese subjects with lymphoma.

  9. Quantification of sofosbuvir and ledipasvir in human plasma by UPLC-MS/MS method: Application to fasting and fed bioequivalence studies.

    PubMed

    Rezk, Mamdouh R; Bendas, Ehab R; Basalious, Emad B; Karim, Iman A

    2016-08-15

    A rapid and sensitive LC-MS/MS method was developed, optimized and validated for quantification of sofosbuvir (SF) and ledipasvir (LD) in human plasma using eplerenone as an internal standard (IS). Analytes and IS were extracted from plasma by simple liquid-liquid extraction technique using methyl tertiary butyl ether. The prepared samples were chromatographed on Acquity UPLC BEH C18 column. Separation was done using a mobile phase formed of 0.1% formic acid and acetonitrile (50:50, v/v) in an isocratic mode at a flow rate of 0.4ml/min. The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. A full validation of the method was performed according to the FDA guidelines. Linearity was found to be in the range of 0.25-3500ng/ml for SF and 5-2000ng/ml for LD. The intra-day and inter-day precision and accuracy results were within the acceptable limits. A short run time of 2min allows analysis of more than 400 plasma samples per day. The developed method was successfully applied to both fasting and fed bioequivalence studies in healthy human volunteers.

  10. A UPLC-MS/MS method for simultaneous quantitation of three monoterpene glycosides and four alkaloids in rat plasma: application to a comparative pharmacokinetic study of Huo Luo Xiao Ling Dan and single herb extract.

    PubMed

    Ai, Yu; Wu, Yun; Wang, Fenrong; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua

    2015-03-01

    The objective of this study was to develop a sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantitation of three monoterpene glycosides (paeoniflorin, alibiflorin and oxypaeoniflorin) and four alkaloids (tetrahydropalmatine, corydaline, dehydrocorydaline and berberine), the main active ingredients of Radix Paeoniae Rubra extract (RPE) and Corydalis yanhusuo extract (CYE) in Huo Luo Xiao Ling Dan (HLXLD), and to compare the pharmacokinetics of these active ingredients in normal and arthritic rats orally administrated with HLXLD or RPE/CYE alone. The analytes and internal standard (IS) (geniposide) were separated on a XBridge C18 column (150 × 4.6 mm, 3.5 µm) using gradient elution with the mobile phase consisting of methanol and 0.01% formic acid in water at a flow rate of 0.6 ml/min. The detection of the analytes was performed on Acquity UPLC-MS/MS system with an electrospray ionization and multiple reaction monitoring mode via polarity switching between negative (for monoterpene glycosides) and positive (for alkaloids) ionization mode. The lower limits of quantification were 2.5, 1, 0.5, 0.2, 0.2, 0.02 and 0.01 ng/ml for paeoniflorin, alibiflorin, oxypaeoniflorin, tetrahydropalmatine, corydaline, dehydrocorydaline and berberine, respectively. Intra-day and inter-day precision and accuracy of analytes were well within acceptance criteria (15%). The mean extraction recoveries of analytes and IS from rat plasma were all more than 83.1%. The validated method has been successfully applied to determination of the analytes. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes between herbal formula and single herb group, normal and arthritic group.

  11. A novel, sensitive and selective method of UPLC/MS-MS for rapid simultaneous determination of midodrine and its active metabolite desglymidodrine in human plasma: Application to support bioequivalence study in healthy human volunteers.

    PubMed

    Patel, Daxesh P; Nair, Sneha; Suhagia, Bhanubhai N; Patel, Bhargav M

    2016-11-30

    A specific, rapid, sensitive and selective ultra-performance liquid chromatography - tandem mass spectrometry has been developed for the simultaneous determination of midodrine and desglymidodrine in human plasma. The analytes and its deuterated analogs were quantitatively extracted from 100μL of human plasma by solid phase extraction technique. Separation of analytes was achieved on the Waters Acquity UPLC BEH C18 (50×2.1mm, 1.7μm) column using acetonitrile-4.0mM ammonium formate, pH 2.5(90:10, v/v) as mobile phase. The protonated analytes were quantified by selected reaction monitoring in the positive ionization mode by triple quadrupole mass spectrometer. The calibration plots were linear over the concentration range of 0.050-50.0ng/mL. The intra-batch and inter-batch precision (%CV) across quality control levels was <4.0 and the% mean relative recovery was ≥96%. Various other parameters like stability in different conditions; matrix effect and reproducibility of the method were performed in accordance with the guidelines specified by the USFDA for bioanalytical method development and validation. The developed method was successfully administered to the pharmacokinetics study of 5 mg midodrine tablet in 12 healthy subjects. Reproducibility of assay was proved by reanalysis of 48 incurred samples.

  12. Development, optimization and validation of a highly sensitive UPLC-ESI-MS/MS method for simultaneous quantification of amlodipine, benazeprile and benazeprilat in human plasma: application to a bioequivalence study.

    PubMed

    Rezk, Mamdouh R; Badr, Kamal A

    2014-09-01

    A rapid, simple, sensitive and specific LC-MS/MS method has been developed and validated for the simultaneous estimation of amlodipine (AML), benazepril (BEN) and benazeprilat (BNT) using eplerenone and torsemide as internal standards (IS). The Xevo TQD LC-MS/MS was operated under the multiple-reaction monitoring mode using electrospray ionization. Sample preparation involves both extraction and precipitation techniques. The reconstituted samples were chromatographed on Acquity UPLC BEH C18 (50mm×2.1mm, 1.7μm) column by pumping 0.1% formic acid and acetonitrile in a gradient mode at a flow rate of 0.45ml/min. A detailed validation of the method was performed as per the FDA guidelines and the standard curves were found to be linear in the range of 0.1-5ng/ml for AML; 5-1200ng/ml for both BEN and BNT. The intra-day and inter-day precision and accuracy results were within the acceptable limits. A run time of 2.5min for each sample made it possible to analyze more than 300 human plasma samples per day. The developed assay method was successfully applied to a bioequivalence study in human volunteers.

  13. Simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma by UPLC-MS/MS and its application to a pharmacokinetic study after administration of Reduning injection.

    PubMed

    Wang, Yanjuan; Wen, Jing; Zheng, Weihua; Zhao, Longshan; Fu, Xiaohuan; Wang, Zhenzhong; Xiong, Zhili; Li, Famei; Xiao, Wei

    2015-01-01

    A simple, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one-step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid-methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra- and inter-day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection.

  14. Simultaneous determination of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside, senkyunolide I in Beagle dogs plasma by UPLC-MS/MS and its application to a pharmacokinetic study after Oral Administration of Shaofu Zhuyu Decoction.

    PubMed

    Huang, Xiaochen; Su, Shulan; Cui, Wenxia; Liu, Pei; Duan, Jin-ao; Guo, Jianming; Li, Zhenhao; Shang, Erxin; Qian, Dawei; Huang, Zhijun

    2014-07-01

    In this present study, a sensitive and rapid UPLC-MS/MS method was developed for simultaneous quantification of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside and senkyunolide I in Beagle dog plasma after oral administration of the Shao-Fu-Zhu-Yu Decoction. Chloramphenicol and clarithromycin were used as internal standards. Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100mm×2.1mm, 1.7μm) at a flow-rate of 0.4mL/min, using 0.1% formic acid-acetonitrile as mobile phase. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. After validation, this method was successfully applied to a pharmacokinetic study. The results showed that the apparent plasma clearance of paeoniflorin, albiflorin, typhaneoside and senkyunolide I were significantly higher than others. Double peak was observed in plasma concentration curves of tetrahydropalmatine, the ferulic acid had a good absorption in Beagle dog plasma, and senkyunolide I was detected in plasma from the first blood sampling time (15min) and rapidly reached Tmax. The compound of typhaneoside has a low bioavailability according to the results.

  15. Rapid analysis of the main components of the total glycosides of Ranunculus japonicus by UPLC/Q-TOF-MS.

    PubMed

    Rui, Wen; Chen, Hongyuan; Tan, Yuzhi; Zhong, Yanmei; Feng, Yifan

    2010-05-01

    A rapid method for the analysis of the main components of the total glycosides of Ranunculus japonicus (TGOR) was developed using ultra-performance liquid chromatography with quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS). The separation analysis was performed on a Waters Acquity UPLC system and the accurate mass of molecules and their fragment ions were determined by Q-TOF MS. Twenty compounds, including lactone glycosides, flavonoid glycosides and flavonoid aglycones, were identified and tentatively deduced on the basis of their elemental compositions, MS/MS data and relevant literature. The results demonstrated that lactone glycosides and flavonoids were the main constituents of TGOR. Furthermore, an effective and rapid pattern was established allowing for the comprehensive and systematic characterization of the complex samples.

  16. Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma by UPLC-MS-MS and its Application to Pharmacokinetic Study.

    PubMed

    Chen, Mengchun; Song, Wenjie; Wang, Shuanghu; Chen, Qiulei; Pan, Peipei; Xu, Tao; Hu, Guoxin; Zheng, Zhiqiang

    2016-08-01

    A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the simultaneous determination of bosentan (BOS), glimepiride (GLP), hydroxyl bosentan (HYBOS) and hydroxyl glimepiride (M1) in rat plasma using one-step protein precipitation was developed and validated. After addition of ambrisentan as an internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm particle size, Waters Corp., Milford, MA, USA) and inline 0.2 μm stainless steel frit filter (Waters Corp.) with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min with gradient elution. The column temperature was maintained at 40°C. Only 4 min was needed for an analytical run. The retention times were ∼3.29 min for BOS, 3.56 min for GLP, 1.42 min for HYBOS, 1.53 min for M1 and 3.22 min for IS. Electrospray ionization source was employed and operated in positive-ion mode; multiple reaction monitoring mode was applied to target fragment ions m/z 552 → 202, m/z 568 → 202, m/z 491 → 352, m/z 507 → 352 and m/z 379 → 347 for BOS, HYBOS, GLP, M1 and IS, respectively. The assay was validated over concentration ranges of 25-5,000 ng/mL (r(2) = 0.9984) for BOS, 1-200 ng/mL (r(2) = 0.9999) for GLP, 0.5-100 ng/mL (r(2) = 0.9999) for HYBOS and 0.1-20 ng/mL (r(2) = 0.9984) for M1. Intra- and interday precision values for replicate quality control samples were within 14.2% for all analytes during the assay validation. Mean quality control accuracy values were within -3.3 to 14.4% of nominal values for all analytes. The mean recoveries of BOS, GLP, HYBOS, M1 and ambrisentan from the plasma exceeded 90.4%. The analytes were stable in rat plasma for at least 2 h at room temperature, 30 days at -40°C and following at least three freeze-thaw cycles (-40°C to room temperature). This method was

  17. UPLC-MS-MS method for simultaneous determination of caffeine, tolbutamide, metoprolol, and dapsone in rat plasma and its application to cytochrome P450 activity study in rats.

    PubMed

    Liu, Yan; Li, Xiang; Yang, Chunjuan; Tai, Sheng; Zhang, Xiangning; Liu, Gaofeng

    2013-01-01

    A specific ultra-performance liquid chromatography tandem mass spectrometry method has been described for the simultaneous determination of caffeine, tolbutamide, metoprolol and dapsone in rat plasma, which are the four probe drugs of the four cytochrome P450 (CYP450) isoforms CYP1A2, CYP2C9, CYP2D6 and CYP3A4. The chromatographic separation was achieved using a Waters Acquity UPLC BEH HILIC C(18) column (2.1 × 50 mm, 1.7 µm). The mobile phase consisted of acetonitrile and water (containing 0.1% formic acid) (15:85, v/v). The triple quadrupole mass spectrometric detection was operated by positive electrospray ionization. Phenacetin was chosen as internal standard. Plasma samples were extracted with dichloromethane-butanol (10:1, v/v). The recoveries ranged from 67.5% to 98.5%. The calibration curves in plasma were linear in the range of 2.5-1,000 ng/mL for caffeine and dapsone, 5-5,000 ng/mL for tolbutamide and 2.5-250 ng/mLfor metoprolol, with correlation coefficient (r(2)) of 0.9936, 0.9966, 0.9990 and 0.9998, respectively. The method was successfully applied to pharmacokinetic studies of the four probe drugs of the four CYP450 isoforms and used to evaluate the effects of breviscapine on the activities of CYP1A2, CYP2C9, CYP2D6 and CYP3A4 in rats.

  18. Simultaneous determination of the bioactive components in rat plasma by UPLC-MS/MS and application in pharmacokinetic studies after oral administration of Radix scutellariae extract.

    PubMed

    Tao, Jin-Hua; Xu, Jun; Jiang, Shu; Ling, Yong; Wang, Dong-Geng

    2017-02-16

    A highly sensitive and rapid ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed and validated for simultaneous quantification of the four main bioactive compounds, i.e., baicalin, baicalein, wogonoside and wogonin in rat plasma after oral administration of Radix scutellariae extract. Clarithromycin was used as an internal standard (IS). Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 µm) at a flow rate of 0.4 mL/min, using 0.1% formic acid-acetonitrile as mobile phase. The MS/MS ion transit ions monitored were 447.5 → 270.1 for baicalin, 270.1 → 168.1 for baicalein, 461.2 → 284.0 for wogonoside, 284.2 → 168.1 for wogonin and 748.5 → 158.1 for IS. Method validation was performed according to Food and Drug Administration guidelines and the results met the acceptance criteria. The lower limit of quantification (LLOQ) achieved was 1.13 ng/mL for baicalin, 1.23 ng/mL for baicalein, 0.82 ng/mL for wogonoside and 0.36 ng/mL for wogonin, respectively. The calibration curves obtained were linear (r > 0.99) over the concentration range approximately 1-1000 ng/mL. The intra- and inter-day precision was less than 15% and the accuracy was within ±14.7%. After validation, this method was successfully applied to a pharmacokinetic study of Radix scutellariae extract.

  19. A novel stability-indicating UPLC method development and validation for the determination of seven impurities in various diclofenac pharmaceutical dosage forms.

    PubMed

    Azougagh, M; Elkarbane, M; Bakhous, K; Issmaili, S; Skalli, A; Iben Moussad, S; Benaji, B

    2016-09-01

    An innovative simple, fast, precise and accurate ultra-high performance liquid chromatography (UPLC) method was developed for the determination of diclofenac (Dic) along with its impurities including the new dimer impurity in various pharmaceutical dosage forms. An Acquity HSS T3 (C18, 100×2.1mm, 1.8μm) column in gradient mode was used with mobile phase comprising of phosphoric acid, which has a pH value of 2.3 and methanol. The flow rate and the injection volume were set at 0.35ml·min(-1) and 1μl, respectively, and the UV detection was carried out at 254nm by using photodiode array detector. Dic was subjected to stress conditions from acid, base, hydrolytic, thermal, oxidative and photolytic degradation. The new developed method was successfully validated in accordance to the International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection, limit of quantitation, precision, linearity, accuracy and robustness. The degradation products were well resolved from main peak and its seven impurities, proving the specificity power of the method. The method showed good linearity with consistent recoveries for Dic content and its impurities. The relative percentage of standard deviation obtained for the repeatability and intermediate precision experiments was less than 3% and LOQ was less than 0.5μg·ml(-1) for all compounds. The new proposed method was found to be accurate, precise, specific, linear and robust. In addition, the method was successfully applied for the assay determination of Dic and its impurities in the several pharmaceutical dosage forms.

  20. A New Method to Quantify Ifosfamide Blood Levels Using Dried Blood Spots and UPLC-MS/MS in Paediatric Patients with Embryonic Solid Tumours

    PubMed Central

    Chávez-Pacheco, Juan L.; Navas, Carlos F.; Demetrio, Joel A.; Alemón-Medina, Radamés; Trujillo, Francisca; Pérez, Martín; Zapata, Martha M.; Cárdenas, Rocío; Salinas, Citlaltepetl; Aquino, Arnoldo; Velázquez-Cruz, Rafael; Castillejos, Manuel-de-Jesús

    2015-01-01

    Ifosfamide blood concentrations are necessary to monitor its therapeutic response, avoiding any adverse effect. We developed and validated an analytical method by UPLC-MS/MS to quantify ifosfamide in dried blood spots (DBS). Blood samples were collected on Whatman 903® filter paper cards. Five 3 mm disks were punched out from each dried blood spot. Acetonitrile and ethyl acetate were used for drug extraction. Chromatographic separation was carried out in an Acquity UPLC equipment with a BEH-C18 column, 2.1 x 100 mm, 1.7 μm (Waters®). The mobile phase consisted in 5 mM ammonium formate and methanol:acetonitrile (40:48:12 v/v/v) at 0.2 mL/min. LC-MS/MS detection was done by ESI+ and multiple reaction mode monitoring, ionic transitions were m/z1+ 260.99 > 91.63 for ifosfamide and 261.00 > 139.90 for cyclophosphamide (internal standard). This method was linear within a 100–10000 ng/mL range and it was accurate, precise and selective. Ifosfamide samples in DBS were stable for up to 52 days at -80°C. The procedure was tested in 14 patients, ages 1 month to 17 years (9 males and 5 females), with embryonic tumours treated with ifosfamide, alone or combined, at a public tertiary referral hospital. Ifosfamide blood levels ranged from 11.1 to 39.7 μmol/L at 12 hours after the last infusion, while 24-hour levels ranged from 0.7–19.7 μmol/L. The median at 12 hours was 19.5 μmol/L (Q25 14.4–Q75 29.0) and 3.8 μmol/L (Q25 1.5–Q75 9.9) at 24 hours, p<0.001. This method is feasible to determine ifosfamide plasma levels in paediatric patients. PMID:26600181

  1. Simultaneous determination of harmine, harmaline and their metabolites harmol and harmalol in beagle dog plasma by UPLC-ESI-MS/MS and its application to a pharmacokinetic study.

    PubMed

    Zhang, Lei; Teng, Liang; Gong, Can; Liu, Wei; Cheng, Xuemei; Gu, Shenghua; Deng, Zhongping; Wang, Zhengtao; Wang, Changhong

    2013-11-01

    Harmine (HAR) and harmaline (HAL) were metabolized by demethylation to form harmol (HOL) and harmalol (HAM) both in vivo and in vitro. It has been demonstrated tremendous value of HAR, HAL and their metabolites in the therapy of Alzheimer's disease. A rapid, selective and sensitive UPLC-ESI-MS/MS method was firstly developed and validated for the simultaneous determination of HAR, HAL, HOL, and HAM in beagle dog plasma with 9-aminoacridine as the internal standard (IS). After protein precipitation with acetonitrile, the analytes were separated within 4.5 min on an ACQUITY UPLC BEH C18 column with a gradient elution system composed of 0.1% formic acid and acetonitrile at a flow rate of 0.4 ml/min. Detection was performed using multiple reactions monitoring mode under a positive ionization condition. The calibration curves of four analytes showed good linearity (r(2)>0.9959) within the tested concentration ranges. The low limit of quantification for HAR, HAL, HOL, and HAM were all 1.00 ng/ml. The mean accuracy of the analytes was within the range of 94.56-112.23%, the R.S.D. values of intra-day and the inter-day precision were less than 6.26% and 7.51%, respectively. Matrix effects and extraction recoveries of the analytes from the beagle dog plasma were within the range of 94.48-105.77% and 89.07-101.44%, respectively. The validated method was successfully applied to a pharmacokinetic study of HAR, HAL, HOL, and HAM in beagle dogs after intravenous administration of HAR and HAL both of 1.0mg/kg. The main pharmacokinetic parameters of Cmax, Vd, CL, AUC and MRT, except Ke and t1/2 values, showed significant difference between the two parent drug HAR and HAL, respectively (p<0.05-0.001). Because of the different metabolic rate of HAR and HAL in vivo, the two metabolites, HOL and HAM, exhibited unique pharmacokinetic properties.

  2. A New Method to Quantify Ifosfamide Blood Levels Using Dried Blood Spots and UPLC-MS/MS in Paediatric Patients with Embryonic Solid Tumours.

    PubMed

    Torres, Luz-María; Rivera-Espinosa, Liliana; Chávez-Pacheco, Juan L; Navas, Carlos F; Demetrio, Joel A; Alemón-Medina, Radamés; Trujillo, Francisca; Pérez, Martín; Zapata, Martha M; Cárdenas, Rocío; Salinas, Citlaltepetl; Aquino, Arnoldo; Velázquez-Cruz, Rafael; Castillejos, Manuel-de-Jesús

    2015-01-01

    Ifosfamide blood concentrations are necessary to monitor its therapeutic response, avoiding any adverse effect. We developed and validated an analytical method by UPLC-MS/MS to quantify ifosfamide in dried blood spots (DBS). Blood samples were collected on Whatman 903® filter paper cards. Five 3 mm disks were punched out from each dried blood spot. Acetonitrile and ethyl acetate were used for drug extraction. Chromatographic separation was carried out in an Acquity UPLC equipment with a BEH-C18 column, 2.1 x 100 mm, 1.7 μm (Waters®). The mobile phase consisted in 5 mM ammonium formate and methanol:acetonitrile (40:48:12 v/v/v) at 0.2 mL/min. LC-MS/MS detection was done by ESI+ and multiple reaction mode monitoring, ionic transitions were m/z1+ 260.99 > 91.63 for ifosfamide and 261.00 > 139.90 for cyclophosphamide (internal standard). This method was linear within a 100-10000 ng/mL range and it was accurate, precise and selective. Ifosfamide samples in DBS were stable for up to 52 days at -80°C. The procedure was tested in 14 patients, ages 1 month to 17 years (9 males and 5 females), with embryonic tumours treated with ifosfamide, alone or combined, at a public tertiary referral hospital. Ifosfamide blood levels ranged from 11.1 to 39.7 μmol/L at 12 hours after the last infusion, while 24-hour levels ranged from 0.7-19.7 μmol/L. The median at 12 hours was 19.5 μmol/L (Q25 14.4-Q75 29.0) and 3.8 μmol/L (Q25 1.5-Q75 9.9) at 24 hours, p<0.001. This method is feasible to determine ifosfamide plasma levels in paediatric patients.

  3. Development and validation of an UPLC-MS/MS assay for quantitative analysis of the ghrelin receptor inverse agonist PF-5190457 in human or rat plasma and rat brain.

    PubMed

    Ghareeb, Mwlod; Leggio, Lorenzo; El-Kattan, Ayman; Akhlaghi, Fatemeh

    2015-07-01

    PF-5190457 is a ghrelin receptor inverse agonist that is currently undergoing clinical development for the treatment of alcoholism. Our aim was to develop and validate a simple and sensitive assay for quantitative analysis of PF-5190457 in human or rat plasma and rat brain using liquid chromatography-tandem mass spectrometry. The analyte and stable isotope internal standard were extracted from 50 μL plasma or rat brain homogenate by protein precipitation using 0.1% formic acid in acetonitrile. Chromatography was carried out on an Acquity UPLC BEH C18 (2.1 mm × 50 mm) column with 1.7 μm particle size and 130 Å pore size. The flow rate was 0.5 mL/min and total chromatographic run time was 2.2 min. The mobile phase consisted of a gradient mixture of water: acetonitrile 95:5% (v/v) containing 0.1% formic acid (solvent A) and 100% acetonitrile containing 0.1% formic acid (solvent B). Multiple reaction monitoring was carried out in positive electro-spray ionization mode using m/z 513.35 → 209.30 for PF-5190457 and m/z 518.47 → 214.43 for the internal standard. The recovery ranged from 102 to 118% with coefficient of variation (CV) less than 6% for all matrices. The calibration curves for all matrices were linear over the studied concentration range (R(2) ≥ 0.998, n = 3). The lower limit of quantification was 1 ng/mL in rat or human plasma and 0.75 ng/g in rat brain. Intra- and inter-run mean percent accuracies were between 85 and 115% and percent imprecision was ≤15%. The assays were successfully utilized to measure the concentration of PF-5190457 in pre-clinical and clinical pharmacology studies of the compound.

  4. Development of RP UPLC-TOF/MS, stability indicating method for omeprazole and its related substances by applying two level factorial design; and identification and synthesis of non-pharmacopoeial impurities.

    PubMed

    Jadhav, Sushant Bhimrao; Kumar, C Kiran; Bandichhor, Rakeshwar; Bhosale, P N

    2016-01-25

    A new UPLC-TOF/MS compatible, reverse phase-stability indicating method was developed for determination of Omeprazole (OMP) and its related substances in pharmaceutical dosage forms by implementing Design of Experiment (DoE) i.e. two level full factorial Design (2(3)+3 center points=11 experiments) to understand the Critical Method Parameters (CMP) and its relation with Critical Method Attribute (CMA); to ensure robustness of the method. The separation of eleven specified impurities including conversion product of OMP related compound F (13) and G (14) i.e. Impurity-I (1), OMP related compound-I (11) and OMP 4-chloro analog (12) was achieved in a single method on Acquity BEH shield RP18 100 × 2.1 mm, 1.7 μm column, with inlet filter (0.2 μm) using gradient elution and detector wavelength at 305 nm and validated in accordance with ICH guidelines and found to be accurate, precise, reproducible, robust and specific. The drug was found to degrade extensively in heat, humidity and acidic conditions and forms unknown degradation products during stability studies. The same method was used for LC-MS analysis to identify m/z and fragmentation of maximum unknown impurities (Non-Pharmacopoeial) i.e. Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9) formed during stability studies. Based on the results, degradation pathway for the drug has been proposed and synthesis of identified impurities i.e. impurities (Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9)) are discussed in detail to ensure in-depth understanding of OMP and its related impurities and optimum performance during lifetime of the product.

  5. Validated UPLC method for the fast and sensitive determination of steroid residues in support of cleaning validation in formulation area.

    PubMed

    Fekete, Szabolcs; Fekete, Jeno; Ganzler, Katalin

    2009-04-05

    An ultra performance liquid chromatographic (UPLC) method was developed for simultaneous determination of seven steroid (dienogest, finasteride, gestodene, levonorgestrel, estradiol, ethinylestradiol, and norethisterone acetate) active pharmaceutical ingredient (API) residues. A new, generic method is presented, with which it is possible to verify the cleaning process of a steroid producing equipment line used for the production of various pharmaceuticals. The UPLC method was validated using an UPLC BEH C18 column with a particle size of 1.7 microm (50 mm x 2.1 mm) and acetonitrile-water (48:52, v/v) as mobile phase at a flow rate of 0.55 ml/min. Method development and method validation for cleaning control analysis are described. The rapid UPLC method is suitable for cleaning control assays within good manufacturing practices (GMP) of the pharmaceutical industry.

  6. [Study on chemical constituents in stems of Nelumbo nucifera by UPLC-ESI/Q-TOF-MS/MS].

    PubMed

    Shan, Feng; Yuan, Yuan; Kang, Li-ping; Huang, Lu-qi

    2015-08-01

    This paper employed UPLC-Electrospray Ionization /Quadrupole-Time of Flight-Mass /Mass Spectrometry( UPLC-ESI/Q-TOF-MS/MS) to analyze the chemical constituents in the stems of Nelumbo nucifera. The stems of N. nucifera were extracted with 75% methanol, and we applied an Agilent Zorbax SB-Aq column (2.1 mm x 100 mm, 1.8 μm) to UPLC analysis with water methanol-water( containing 0.05% formic acid) in gradient as mobile phase. The eluates were then detected by ESI-Q-TOF-MS/MS. Results indicated that 22 benzylisoquinoline alkaloids were indendified. Among them, one alkaloid may be a new compound and a component was found in the Lotus for the first time. We fully identify the composition of the Lotus stems for the first time, Which could provides theoretical foundation for further study and utilization of the medicinal resources.

  7. Determination and validation of six sunscreen agents in suncare products by UPLC and HPLC.

    PubMed

    Lee, So-Mi; Jeong, Hye-Jin; Chang, Ih Seop

    2008-01-01

    Methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine are sunscreen agents that have hydrophobic behaviors in common. They were not normally assayed with the following four sunscreen agents that have hydrophilic behaviors in a single chromatographic run: ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. For that reason, methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine require much time in order to assay products with those materials. A rapid, selective, and reproducible determination method needs to be developed for the simultaneous examination of methylene bis-benzotriazolyl tetramethyl butylphenol and bis-ethylhexyloxy phenol methoxyphenyl triazine with the sunscreen agents, ethylhexyl methoxycinnamate, isoamyl p-methoxycinnamate, ethylhexyl salicylate, and ethylhexyl triazone. This new technique could reduce time in examining the sunscreen agents and be effective for quality control of suncare products. In this paper, the HPLC and UPLC system is used for developing the determination of the sunscreen agents. Several evaluations of some mixtures of eluents and columns were obtained for the optimal condition of separation. In HPLC, the optimal peak resolution was obtained through ethanol-water gradient elution and a 75-mm C18 column with a 3.5-microm-sized particle on a flow rate of 1.0 ml/min. In UPLC, the most distinctive peak resolution was obtained through methanol-water gradient elution and a 50-mm C18 column with a 1.7-microm-sized particle on a flow rate 0.4 ml/min. Both of those chromatographic determination methods could be used in the examination of six types of sunscreen agents without any interference from other product excipients in the agents. The proposed determination methods were validated for specificity, linearity, repeatability, system stability, intermediate precision, and accuracy

  8. UPLC: a preeminent technique in pharmaceutical analysis.

    PubMed

    Kumar, Ashok; Saini, Gautam; Nair, Anroop; Sharma, Rishbha

    2012-01-01

    The pharmaceutical companies today are driven to create novel and more efficient tools to discover, develop, deliver and monitor the drugs. In this contest the development of rapid chromatographic method is crucial for the analytical laboratories. In precedent decade, substantial technological advances have been done in enhancing particle chemistry performance, improving detector design and in optimizing the system, data processors and various controls of chromatographic techniques. When all was blended together, it resulted in the outstanding performance via ultra-high performance liquid chromatography (UPLC), which holds back the principle of HPLC technique. UPLC shows a dramatic enhancement in speed, resolution as well as the sensitivity of analysis by using particle size less than 2 pm and the system is operational at higher pressure, while the mobile phase could be able to run at greater linear velocities as compared to HPLC. This technique is considered as a new focal point in field of liquid chromatographic studies. This review focuses on the basic principle, instrumentation of UPLC and its advantages over HPLC, furthermore, this article emphasizes various pharmaceutical applications of this technique.

  9. Evaluation of superficially porous and fully porous columns for analysis of drugs in plasma samples by UHPLC-MS/MS.

    PubMed

    Acquaro, Vinicius Ricardo; Lanças, Fernando Mauro; Queiroz, Maria Eugênia Costa

    2017-03-24

    This work compares the performance of recently introduced C18 superficially porous columns (four columns) and C18 fully porous columns (two columns), with different particle sizes, during the analysis of drugs in plasma samples by MS/MS detection. The following chromatographic parameters were evaluated for all the columns: reduced plate height (h) vs reduced linear velocity (v), impedance vs v, chromatographic run time vs flow rate (mLmin(-1)), backpressure vs flow rate (mLmin(-1)), resolution, peak capacity, asymmetry, and retention factor. By using DAD detection, hydrophobicity, silanol activity, and metal impurities were also assessed for the columns. The columns with charged surface displayed improved chromatographic efficiency for the drugs in their ionized form. The columns with particles smaller than 2μm (Cortecs 1.6μm, Acquity 1.7μm, and Kinetex 1.7μm) presented higher chromatographic efficiency for the drugs, which were in their partially ionized form. The generated mathematical models were able to predict the backpressure and chromatographic run time at different flow rates for all the columns. Considering the efficiency, impedance, resolution, peak capacity, retention factor, and hydrophobicity, Cortecs 1.6μm and Acquity 1.7μm were the columns that given the best performance during analysis of the target drugs in plasma samples.

  10. Therapeutic monitoring of amphotericin B in Saudi ICU patients using UPLC MS/MS assay.

    PubMed

    Al-Quadeib, Bushra T; Radwan, Mahasen A; Siller, Lidija; Mutch, Elaine; Horrocks, Ben; Wright, Matthew; Alshaer, Abdulaziz

    2014-12-01

    Amphotericin B (AmB) is the first-line agent for the treatment of life-threatening invasive fungal infections. The aim of this study was to monitor AmB in critically ill Saudi patients in ICU after i.v. administration of 0.68 ± 0.1 mg/kg/day Fungizone®. A selective, sensitive and precise UPLC MS/MS method was developed to measure AmB concentrations in these patients. Seven ICU patients with creatinine clearance (ClCr) >40 mL/min were included. AmB levels were analyzed using a Waters Aquity UPLC MS/MS system, a BEH Shield RP18 column and detection via electrospray ionization source with positive ionization mode. The precision and accuracy of the developed UPLC method in the concentration range of 200-4000 ng/mL show no significant difference among inter- and-intra-day analysis (p > 0.05). Linearity was observed over the investigated range with correlation coefficient, r > 0.995 (n = 6/day). The pharmacokinetics of AmB in these patients, at steady state, showed a high terminal half-life of 124.6 ± 73.4 h, with a highest concentration of 513.9 ± 281.1 ng/mL, a lowest concentration 316.4 ± 129.0 ng/mL and a mean clearance 91.1 ± 39.2 mL/h/kg. The pharmacokinetics of AmB in critically ill Saudi patients in ICU was studied using a fully validated assay. A weak correlation (r = -0.22) of AmB Cl with ClCr was obtained, which suggests the need for further investigation in a larger population.

  11. [Simultaneous determination of 11 mycotoxins in malt by isotope internal standard-UPLC-MS/MS].

    PubMed

    Wang, Sha; Kong, Wei-jun; Yang, Mei-hua

    2016-01-01

    A suitable ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of 11 mycotoxins with isotope internal standard in malt. The mycotoxins in malt were extracted and purified by one-step ultrasonic extraction procedure using acetonitrile/water/acetic acid (80 : 19 : 1), and then detected and confirmed by UPLC-MS/MS, and quantified by isotope labeled AFB1 ([13C17]-AFB1) and ZEN ([13C18]-ZEN) internal standards. Rapid separation of the 11 mycotoxins was successfully achieved on a Phenomenex Kinetex C18 column (100 mm x 2.1 mm, 2.6 μm) with gradient elution using the mobile phase of methanol containing 0.1% formic acid and 2 mmol x L(-1) ammonium acetate in water. Simultaneous acquisition was performed in multiple reaction monitoring (MRM) mode with electrospray ionization (ESI) source operated in both positive and negative ionization modes. The established method provided a good linearity for the 11 mycotoxins within their respective linear ranges with correlation coefficients all higher than 0.999 1. The average recoveries ranged from 75.0% to 117.0% with relative standard deviations (RSDs) below 5.1%. The limits of detection (LODs) and quantitation (LOQs) ranged from 0.05 to 30 μg x kg(-1) and 0.15 to 87.5 μg x kg(-1), respectively, which were below the maximum residue levels (MRLs) set by the European Union. Twenty malt samples were analyzed and nine samples were detected with mycotoxins, which were confirmed according to the same fragment ions found in positive samples and the standards at the same retention time. This study has demonstrated that the one-step extraction procedure of mycotoxins from complex matrices coupled to UPLC-MS/MS method is simple, quick, accurate and sensitive for quantitative and qualitative analysis of multiple mycotoxins in malt.

  12. Tissue distribution study of salvianolic acid B long-circulating liposomes in mice by UPLC-MS/MS determination.

    PubMed

    Pi, Jiaxin; Liu, Zhidong; Shu, Lexin; Li, Lin; Wang, Ying; Li, Nan; Li, Jiawei

    2015-01-01

    In targeting delivery system research on salvianolic acid B, it's vital but hard to evaluate the tissue distribution for its low concentrations in tissues. So the simple, rapid, selective and sensitive UPLC-MS/MS method was provided hereby to determine the concentration of salvianolic acid B in mice tissues after intravenous administration of salvianolic acid B injections, conventional liposomes and long-circulating liposomes. The UPLC was conducted by a C(18) column with a gradient mobile phase consisting of acetonitrile and water containing 0.1% formic acid. The tandem mass spectrometry was operated in negative-electrospray ionization selected-reaction-monitoring mode, and the optimized characteristic precursor to product ion transition m/z 717.3→519.1 was selected. The biosamples were homogenized and treated with a protein precipitation, which led to an acceptable matrix effect and extraction recovery. The linear calibration curves were plotted in the given concentration ranges. The intra-day and inter-day precisions were less than 13.9% and the accuracies were in the range of 86.3-109.2%. The tissue distribution results determined by UPLC-MS/MS we developed showed that the conventional and long-circulating liposomes we made had succeeded in prolonging the retention time and increasing the level of salvianolic acid B in certain distribution tissues such as liver, kidney and brain.

  13. UPLC and HPLC of caffeoyl esters in wild and cultivated Arctium lappa L.

    PubMed

    Haghi, Ghasem; Hatami, Alireza; Mehran, Mehdi

    2013-05-01

    Analytical methods including ultra-performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) with photodiode array (PDA) detector were developed for the analysis of caffeoylquinic acid derivatives in seeds, leaves and roots of Arctium lappa L. Separation was performed on C(18) column utilising 5% (v/v) acetic acid in water and acetonitrile at 330 nm. Both methodologies were validated in terms of linearity, precision, and recovery. The results showed that the major advantages of UPLC, over HPLC were the fast analysis, narrow peaks, high sensitivity, and reduction of solvent consumption. Subsequently the methods were applied for the identification and quantification of chlorogenic acid (5-CQA) and 1,5-dicaffeoylquinic acid (1,5-DCQA) as main compounds in samples. The total phenolic content of samples ranged from 3.93 to 14.13 g of 5-CQA equivalent/100g dry weight (DW). There was a significant variability from 89 to 571 mg/100g for 5-CQA and 48 to 486 mg/100g for 1,5-DCQA in dry material.

  14. Simultaneous Determination of Sitagliptin Phosphate Monohydrate and Metformin Hydrochloride in Tablets by a Validated UPLC Method.

    PubMed

    Malleswararao, Chellu S N; Suryanarayana, Mulukutla V; Mukkanti, Khagga

    2012-01-01

    A novel approach was used to develop and validate a rapid, specific, accurate and precise reverse phase ultra performance liquid chromatographic (UPLC) method for the simultaneous determination of Sitagliptin phosphate monohydrate and Metformin hydrochloride in pharmaceutical dosage forms. The chromatographic separation was achieved on Aquity UPLC BEH C8 100 × 2.1 mm, 1.7 μm, column using a buffer consisting of 10 mM potassium dihydrogen phosphate and 2 mM hexane-1-sulfonic acid sodium salt (pH adjusted to 5.50 with diluted phosphoric acid) and acetonitrile as organic solvent in a gradient program. The flow rate was 0.2 mL min(-1) and the detection wavelength was 210 nm. The limit of detection (LOD) for Sitagliptin phosphate monohydrate and Metformin hydrochloride was 0.2 and 0.06 μg mL(-1), respectively. The limit of quantification (LOQ) for Sitagliptin phosphate monohydrate and Metformin hydrochloride was 0.7 and 0.2 μg mL(-1), respectively. This method was validated with respect to linearity, accuracy, precision, specificity and robustness. The method was also found to be stability-indicating.

  15. Analysis of phenolic compounds in Matricaria chamomilla and its extracts by UPLC-UV.

    PubMed

    Haghi, G; Hatami, A; Safaei, A; Mehran, M

    2014-01-01

    Chamomile (Matricaria chamomilla L.) is a widely used medicinal plant possessing several pharmacological effects due to presence of active compounds. This study describes a method of using ultra performance liquid chromatography (UPLC) coupled with photodiode array (PDA) detector for the separation of phenolic compounds in M. chamomilla and its crude extracts. Separation was conducted on C18 column (150 mm × 2 mm, 1.8 μm) using a gradient elution with a mobile phase consisting of acetonitrile and 4% aqueous acetic acid at 25°C. The method proposed was validated for determination of free and total apigenin and apigenin 7-glucoside contents as bioactive compounds in the extracts by testing sensitivity, linearity, precision and recovery. In general, UPLC produced significant improvements in method sensitivity, speed and resolution. Extraction was performed with methanol, 70% aqueous ethanol and water solvents. Total phenolic and total flavonoid contents ranged from 1.77 to 50.75 gram (g) of gallic acid equivalent (GAE)/100 g and 0.82 to 36.75 g quercetin equivalent (QE)/100 g in dry material, respectively. There was a considerable difference from 40 to 740 mg/100 g for apigenin and 210 to 1110 mg/100 g for apigenin 7-glucoside in dry material.

  16. Column performance study of different variants of liquid chromatographic technique: an application on pharmaceutical ternary mixtures containing tetryzoline.

    PubMed

    Salem, Hesham; Hassan, Nagiba Y; Lotfy, Hayam M; Saleh, Sarah S

    2015-01-01

    High-performance liquid chromatography (HPLC), ultra-performance liquid chromatography (UPLC) and rapid resolution liquid chromatographic (RRLC) methods have been developed and validated for the separation and quantitation of both or either of two ternary mixtures present in ophthalmic solutions. The first mixture contains chloramphenicol, dexamethasone sodium phosphate and tetryzoline HCl (TZH); while the second one contains ofloxacin, prednisolone acetate and TZH. Both preparations contain benzalkonium chloride as a preservative. The columns used were a HPLC column (C18 5 µm particle size), a RRLC column (C18 2.6 µm particle size) and a UPLC column (C18 1.7 µm particle size). A comparative study was conducted to illustrate the effect of the change in column particle size and dimensions on the other chromatographic conditions, backpressure and the separation of both ternary mixtures. The methods were validated as per ICH guidelines where accuracy, repeatability, interday precision and robustness were found to be within the acceptable limits. The RRLC column provided shorter run time and better resolution than HPLC, while the UPLC column gave the shortest run time for all columns. The RRLC column resulted in minimum backpressure, so it could be used with any HPLC instrument, which makes the method more practical and economic. The results obtained from the proposed methods were statistically compared with official ones where no significant difference was observed.

  17. Development and validation of a UPLC method for rapid and simultaneous analysis of proton pump inhibitors.

    PubMed

    Addo, Richard T; Davis, Kenneth; Ubale, Ruhi; Owen, Joel S; Watkins, E Blake

    2015-02-01

    Proton pump inhibitors (PPIs) are used extensively for the relief of gastroesophageal reflux, peptic ulcers, and other hypersecretory conditions. Some of the commonly used PPIs-omeprazole, esomeprazole, lansoprazole, pantoprazole, and rabeprazole-were used in this study with the aim of developing a rapid ultra performance liquid chromatography (UPLC) method for detecting each and allowing separation and quantification of a mixture of PPIs. An analysis of samples was performed on a UPLC system equipped with a quaternary solvent delivery system, a refrigerated sample manager, a column heater, a photo diode array detector scanning from 210 to 400 nm, and a C18 analytical column (50 mm × 3.0 mm, 1.7-μm particle size). The chromatographic analysis of the PPI samples and standards was performed using gradient elution with acetonitrile and water. The calibration curve range varied for each of the PPIs ranging from a lower limit of 0.75-1.78 μg/mL to a maximum concentration of 200 μg/mL with a regression coefficient (r (2)) of ≥0.98. The accuracy and precision were calculated, and the %RSD was determined to be ≤0.21% (intraday) and ≤5% (interday). The LOD was 0.23-0.59 μg/mL and the LOQ was 0.71-1.78 μg/mL for each of the drugs analyzed. The method was capable of detecting and quantifying each drug in a mixture with good resolution and a total run time of less than 5 min. Herein, we report an efficient and rapid analytical method for the simultaneous detection of multiple PPIs in a mixture.

  18. Burdach's column.

    PubMed

    Pearce, J M S

    2006-01-01

    After the Greek physicians Herophilus and Galen, the major anatomical advances in the anatomy of the spinal cord were made possible by the microtome devised by Benedikt Stilling in January 1842. This enabled him to cut the frozen, thin sections and examine them, unstained,with the microscope. The technique founded future investigation of the cord's anatomy. Brown-Séquard, Türck, Clarke, Lissauer, Goll, and Flechsig all contributed. An important result of these progressing anatomical experiments was the identification of the posterior columns. In 1826, the German physiologist Karl Friedrich Burdach (1776-1847) described, from macroscopic study, the fasciculus cuneatus, known as the tract of Burdach: the lateral portion of the posterior columns of the cord that terminate in the nucleus cuneatus of the medulla.

  19. A Novel, Rapid, and Validated Stability-Indicating UPLC Method for the Estimation of Drotaverine Hydrochloride and Ibuprofen Impurities in Oral Solid Dosage Form

    PubMed Central

    Vijay Kumar, Rekulapally; Rao, Vinay U.; Anil Kumar, N.; Venkata Subbaiah, B.

    2015-01-01

    A novel, stability-indicating, reversed-phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of pure drotaverine hydrochloride and ibuprofen in the presence of their impurities and degradation products. The method was developed using a Waters UPLC BEH C18, 100 × 2.1 mm, 1.7 µm column with a flow rate of 0.3 mL/min and detector wavelength at 210 nm. The mobile phase consisted of potassium dihydrogen orthophosphate buffer and acetonitrile. Drotaverine hydrochloride and ibuprofen were subjected to the stress conditions of oxidative, acid, base, photolytic, and thermal degradation. Degradation products resulting from the stress studies were well-resolved, thus confirming the test method as stability-indicating. Validation of the method was carried out as per International Conference on Harmonization guidelines. PMID:26839839

  20. Separation of hexabromocyclododecane diastereomers: Application of C18 and phenyl-hexyl ultra-performance liquid chromatography columns.

    PubMed

    Baek, Song-Yee; Lee, Sunyoung; Kim, Byungjoo

    2017-03-10

    This study was performed to establish the proper liquid chromatographic conditions for the separation of hexabromocyclododecane (HBCD) diastereomers. Column selectivity towards HBCD diastereomers was evaluated for C18 and phenyl-hexyl stationary phases. First, the baseline separation of the primary HBCDs (α-, β-, and γ-HBCD) was obtained using the ultra-performance liquid chromatography (UPLC) column with C18 stationary phase chosen in most previous studies for HBCD analysis; however, co-elution of δ- and ε-HBCD with the primary HBCD diastereomers was observed. To prevent the interference from δ- and ε-HBCD, we adopted a phenyl-hexyl UPLC column to resolve the HBCD diastereomers. The phenyl-hexyl UPLC column showed significantly different selectivity for the HBCD diastereomers compared with the C18 column, which allowed the clear isolation of δ-HBCD and ε-HBCD from the primary HBCD diastereomers. In addition, by checking the retention times of all HBCD diastereomers using both C18 and phenyl-hexyl columns, we confirmed the presence of δ-, ε-, η-, and θ-HBCDs in two technical HBCD mixtures.

  1. Orthogonal extraction/chromatography and UPLC, two powerful new techniques for bioanalytical quantitation of desloratadine and 3-hydroxydesloratadine at 25 pg/mL.

    PubMed

    Shen, Jim X; Wang, Haiping; Tadros, Samy; Hayes, Roger N

    2006-02-24

    Validation of the bioanalytical method for determination of desloratadine and 3-hydroxydesloratadine was conducted using ultra high pressure liquid chromatography (UPLC) in conjunction with mix mode solid phase extraction. The dynamic range of the assay was from 0.025 ng/mL to 10 ng/mL using 96-well solid phase extraction. On an UPLC system, the inter-run accuracy was better than 94.7% for desloratadine (n = 18) and 94.0% for 3-hydroxydesloratadine (n = 18). The between-run precision (%CV) ranged from 2.6% to 9.8% for desloratadine (n = 18) and 3.1% to 11.1% for 3-hydroxydesloratadine (n = 18). The limit of quantitation represented 0.478 pg and 0.525 pg of extracted material injected on-column for desloratadine and 3-hydroxydesloratadine, respectively. The total run time was slightly over 2 min per sample. The approach of orthogonal extraction/chromatography and UPLC significantly improves assay performance while also increasing sample throughput for drug development studies.

  2. Pharmacokinetic properties of isorhamnetin, kaempferol and quercetin after oral gavage of total flavones of Hippophae rhamnoides L. in rats using a UPLC-MS method.

    PubMed

    Li, Guowen; Zeng, Xiaoli; Xie, Yan; Cai, Zhenzhen; Moore, Jeffrey C; Yuan, Xiurong; Cheng, Zhihong; Ji, Guang

    2012-01-01

    An ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method was developed to investigate the pharmacokinetic properties of isorhamnetin, kaempferol and quercetin from a total flavone extract of Hippophae rhamnoides L. (TFH) after single dose oral administration. Rat plasma samples were pretreated using liquid-liquid extraction, and chromatographic separation was performed on a C(18) column using a linear gradient of methanol and formic acid (0.1%). The pharmacokinetic parameters of isorhamnetin, kaempferol and quercetin from TFH in rats were quantitatively determined by UPLC with photodiode array detection (PDA). The qualitative detection of the three flavones was accomplished by selected ion monitoring in negative ion mode ESI-MS. Results of the pharmacokinetic study indicate that the three flavones in TFH were absorbed by passive diffusion in rats, and no "double-peak" phenomenon was observed in C-t curves of the three flavones from TFH except for quercetin. Results of this study indicate that the pharmacokinetic behaviors of isorhamnetin, kaempferol and quercetin when administered together in a complex herbal extract might be different than the individual behaviors of the same compounds administered in their pure forms. Results of this study also demonstrate that UPLC-MS is a rapid and practical method to determine the pharmacokinetic parameters of flavones present in an herbal extract.

  3. A New UPLC Method with Chemometric Design-Optimization Approach for the Simultaneous Quantitation of Brimonidine Tartrate and Timolol Maleate in an Eye Drop Preparation.

    PubMed

    Büker, Eda; Dinç, Erdal

    2017-02-01

    A new ultra-performance liquid chromatography (UPLC) with photodiode array was proposed for the quantitation of Brimonidine Tartrate (BRI) and Timolol Maleate (TIM) in eye drop using experimental design and optimization methodology. A 3(3) full factorial design was applied to uncover the effects of the selected factors and their interactions on the chromatographic response function for the optimization of experimental conditions in the development of a new UPLC method. As a result, the optimal chromatographic conditions giving a better separation and short analysis time were found to be 49.2°C for column temperature; 0.38 mL/min for flow rate and 56.7 % (v/v) for 0.1 M CH3COOH used in mobile phase. The elution of BRI and TIM was reported as 0.508 and 0.652 min within a short runtime of 1.5 min, respectively. Calibration graphs for BRI and TIM were obtained by the regression of the concentration on the peak area, which was detected at 246 and 298 nm, respectively. The method validation was performed by the analysis of the synthetic mixtures, intra-day and inter-day samples and standard addition samples. This study shows that the optimized and validated UPLC method is very promising and available for the quantification of BRI and TIM in an eye drop formulation.

  4. Development and validation of a stability indicating RP-UPLC method for determination of quetiapine in pharmaceutical dosage form.

    PubMed

    Trivedi, Rakshit Kanubhai; Patel, Mukesh C

    2011-01-01

    The present work reports a stability indicating reversed phase ultra performance liquid chromatography (RP-UPLC) method for the quantitative determination of quetiapine in pharmaceutical dosage form. The chromatographic separation is performed on an Agilent Eclipse Plus C18, RRHD 1.8 μm (50 mm x 2.1 mm) column using gradient elution. The optimized mobile phase consists of 0.1 % aqueous triethylamine (pH 7.2) as a solvent-A and 80:20 v/v mixture of acetonitrile and methanol as solvent-B. The eluted compounds are monitored at 252 nm wavelength using a UV detector. The developed method separates quetiapine from its five impurities/degradation products within a run time of 5 min. Stability indicating capability of the developed method is established by analyzing forced degradation samples in which the spectral purity of quetiapine is ascertained along with the separation of degradation products from analyte peak. The developed RP-UPLC method is validated as per International Conference on Harmonization (ICH) guidelines with respect to system suitability, specificity, precision, accuracy, linearity, robustness and filter compatibility.

  5. A rapid UPLC method for simultaneous determination of eleven components in ‘Ge-Gen-Qin-Lian’ decoction

    PubMed Central

    An, Rui; You, Lisha; Zhang, Yizhu; Wang, Xinhong; Ma, Yuemin

    2014-01-01

    Background: ‘Ge-Gen-Qin-Lian’ Decoction derived from ‘Shang-Han-Lun’ compiled by Zhang Zhongjing. It is widely used in the treatment of acute gastroenteritis, bacillary dysentery, virus diarrhea. This paper describes a sensitive and specific assay for the determination of the 11-marker compounds using ultra performance liquid chromatography (UPLC). Objective: To develop an UPLC method for simultaneous determination of 11 bioactive compounds in ‘Ge-Gen-Qin-Lian’ preparations. Materials and Methods: The chromatography analysis was performed on an Agilent Proshell 120 EC-C18 column (4.6 × 50 mm, 2.7 μm) at 30°C with a gradient elution of methanol, 0.5% formic acid and 0.5% ammonium acetate at a flow rate 1.0 ml/min and UV detected at 270 nm. Results: All calibration curves showed good linear regression (r ≥ 0.9993) within tested ranges. Limits of detection (LOD) and limits of quantification (LOQ) fell in the range between 0.0691-1.04 μg/ml and 0.23–3.43 μg/ml, respectively. The mean recovery of each herbal medicine ranged from 96.60 to 102.11%. Conclusion: The method was validated for repeatability, precision, stability, accuracy, and selectivity. The validated method was successfully applied to simultaneous analysis of these active components in ‘Ge-Gen-Qin-Lian’ decoction. PMID:25422547

  6. Simultaneous Determination of Rutin, Luteolin, Quercetin, and Betulinic Acid in the Extract of Disporopsis pernyi (Hua) Diels by UPLC

    PubMed Central

    Wang, Yanqi; Li, Shuyi; Han, Dandan; Meng, Kehan; Wang, Miao; Zhao, Chunjie

    2015-01-01

    Disporopsis pernyi (Hua) Diels, which belongs to genus Disporopsis, has been widely used for the treatment of abnormal sweating, chronic cough, and so forth. An ultra-performance liquid chromatography (UPLC) analysis was developed for the determination of rutin, luteolin, quercetin, and betulinic acid in Disporopsis pernyi (Hua) Diels roots. UPLC analysis was conducted by using a Shim-pack XR-ODS column with gradient elution with the mobile phase of acetonitrile and water containing 0.1% formic acid and with a flow rate of 0.2 mL/min, detected at 210, 254, and 280 nm. The method was precise, with relative standard deviation < 2.0%. The recoveries for the four components in Disporopsis pernyi (Hua) Diels were between 98.5 and 100.9%. The average contents of rutin, luteolin, quercetin, and betulinic acid in roots were 5.63, 2.51, 3.87, and 2.41 μg/g, respectively. The method was accurate and reproducible and it can provide a quantitative basis for quality control of Disporopsis pernyi (Hua) Diels. PMID:26798553

  7. Determination of trimethylamine-N-oxide in combination with L-carnitine and γ-butyrobetaine in human plasma by UPLC/MS/MS.

    PubMed

    Grinberga, Solveiga; Dambrova, Maija; Latkovskis, Gustavs; Strele, Ieva; Konrade, Ilze; Hartmane, Dace; Sevostjanovs, Eduards; Liepinsh, Edgars; Pugovics, Osvalds

    2015-11-01

    An ultra-high-performance liquid chromatography-mass spectrometry (UPLC/MS/MS) method was developed and validated for the quantification of trimethylamine-N-oxide (TMAO) simultaneously with TMAO-related molecules L-carnitine and γ-butyrobetaine (GBB) in human blood plasma. The separation of analytes was achieved using a Hydrophilic interaction liquid chromatography (HILIC)-type column with ammonium acetate-acetonitrile as the mobile phase. TMAO determination was validated according to valid US Food and Drug Administration guidelines. The developed method was successfully applied to plasma samples from healthy volunteers.

  8. A single reversed-phase UPLC method for quantification of levofloxacin in aqueous humour and pharmaceutical dosage forms.

    PubMed

    Gupta, Himanshu; Aqil, M; Khar, R K; Ali, Asgar; Chander, Prakash

    2010-07-01

    An attempt was made to develop a single, rapid, specific, and sensitive gradient reversed-phase ultra-performance liquid chromatographic method for quantitative analysis of levofloxacin. The single method thus developed is applied for the quantification of levofloxacin both in aqueous humour as well as pharmaceutical dosage forms (i.e., tablets and eye drops). The newly developed method is applicable for pharmacokinetic studies of eye formulations. The chromatographic separation of levofloxacin was achieved on a Waters Acquity HSS T-3 column (100 x 2.1 mm, 1.8 microm) within a short run-time of 5 min. The method was validated according to the ICH guidelines with respect to system suitability, linearity, limit of quantitation and detection, precision, accuracy, robustness, and specificity. Forced degradation studies were also performed in levofloxacin bulk drug samples to demonstrate the stability-indicating power of the developed ultra-performance liquid chromatography method. The developed method was then successfully applied for the ocular pharmacokinetic study of levofloxacin eye formulations and assay of levofloxacin pharmaceutical dosage form.

  9. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation

    PubMed Central

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M.; Nording, Malin L.

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 < R2 < 0.9996), limit of detection (0.0005–2.1 pg on column), limit of quantification (0.0005–4.2 pg on column), inter- and intraday accuracy (85–115%) and precision (< 5%), recovery (40–109%) and stability (40–105%). Forty-seven of fifty-two bioactive lipids were detected in plasma samples at fasting and in the postprandial state (0.5, 1, and 3 hours after the meal). Multivariate analysis showed a significant shift of bioactive lipid profiles in the postprandial state due to inclusion of dairy products in the diet, which was in line with univariate analysis revealing seven compounds (NAGly, 9-HODE, 13-oxo-ODE, 9(10)-EpOME, 12(13)-EpOME, 20-HETE, and 11,12-DHET) that were significantly different between background diets in the postprandial state (but not at fasting). The only change in baseline levels at fasting

  10. Simultaneous quantification of Amaryllidaceae alkaloids from Zephyranthes grandiflora by UPLC-DAD/ESI-MS/MS.

    PubMed

    Katoch, Deepali; Kumar, Shiv; Kumar, Neeraj; Singh, Bikram

    2012-12-01

    A rapid, simple and sensitive ultra performance liquid chromatography-diode array detection method (UPLC-DAD) was developed and validated for quantification of four biologically important Amaryllidaceae alkaloids viz. lycoramine, hamayne, haemanthamine and tortuosine in Zephyranthes grandiflora. The method employed BEH C(18) column (2.1mm×100mm, 1.7μm particle size) with linear gradient elution of acetonitrile and water (0.05% formic acid) in a flow rate of 0.3mL/min and at λ(max) 280nm. Standard calibration curve for the analytes were linear (r(2)≥0.9999), precise (intra-day RSDs<1.33% and inter-day RSDs<2.67%) and accurate (97.8-105.3%). The developed method was applied to the quality assessment of samples collected during different seasons and showed significant variation with an optimum amounts of these alkaloids in rainy season. The method was also applied for identification of Amaryllidaceae alkaloids in the plant and overall, seventeen Amaryllidaceae alkaloids of different structural types lycorine, haemanthamine, galanthamine, narciclasine were characterised. This study provides a qualitative and quantitative method for analysis of Amaryllidaceae alkaloids.

  11. A validated stability-indicating UPLC method for desloratadine and its impurities in pharmaceutical dosage forms.

    PubMed

    Rao, Dantu Durga; Satyanarayana, N V; Malleswara Reddy, A; Sait, Shakil S; Chakole, Dinesh; Mukkanti, K

    2010-02-05

    A novel stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the determination of purity of desloratadine in presence of its impurities and forced degradation products. The method was developed using Waters Aquity BEH C18 column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 280nm. The run time was 8min within which desloratadine and its five impurities were well separated. Desloratadine was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Desloratadine was found to degrade significantly in oxidative and thermal stress conditions and stable in acid, base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, thus proved the stability-indicating power of the method. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of desloratadine in pharmaceutical dosage forms.

  12. Chromatographic Analysis of a Multicomponent Mixture of B1, B6, B12, Benfotiamine, and Diclofenac; Part I: HPLC and UPLC Methods for the Simultaneous Quantification of These Five Components in Tablets and Capsules.

    PubMed

    Fayed, Ahmed Salah; Hegazy, Maha Abdel-Monem; Wahab, Nada Sayed Abdel

    2016-11-01

    New, simple, highly sensitive, precise, and accurate gradient reversed-phase chromatographic methods were developed using HPLC and ultra-HPLC (UPLC) systems for the determination of five components, namely thiamine, pyridoxine, cyanocobalamin, benfotiamine, and diclofenac in tablets and capsules. The methods were compared for their efficiency in the separation and determination of these five compounds using two different C18 columns (250 × 4.6 mm, 5 μm; and 100 × 4.6 mm, 2.6 μm) for HPLC and UPLC, respectively. Chromatographic separation was performed with a mobile phase containing acetonitrile and 0.025 M phosphate buffer (pH 3.5), with a gradient program and a flow rate of 1.5 and 1.0 mL/min for both methods, respectively. The methods were validated according to International Conference on Harmonization guidelines. Linearity was achieved in the range of 5.00 to 150.00 μg/mL for each of the five compounds. Ruggedness and intermediate precision were confirmed by different analysts on different columns on different days. Moreover, the components were subjected to an accelerated stability study under acidic, alkaline, and oxidative stress conditions and no interfering peaks were observed. The five compounds were efficiently separated in <20 min by HPLC, whereas for UPLC, separation was achieved in <8 min, which dramatically decreased the consumption of organic solvents.

  13. Development and Validation of a Stability-Indicating RP-UPLC Method for the Estimation of Impurities in Cinacalcet Hydrochloride API and its Formulation.

    PubMed

    Sunil Reddy, Pingili; Raju, Thummala Veera Raghava; Raju, Penmetsa Satyanarayana; Varma, Nadimpalli Sunil; Babu, Kondra Sudhakar

    2015-01-01

    A sensitive, stability-indicating, gradient reversed-phase ultra-performance liquid chromatography method has been developed for the quantitative estimation of cinacalcet hydrochloride impurities in active pharmaceutical ingredients and pharmaceutical formulations. Efficient chromatographic separation was achieved on an Acquity BEH Shield RP18, 100 × 2.1 mm, 1.7 µm column with the mobile phase containing pH 6.6 phosphate buffer and acetonitrile. The flow rate of the mobile phase was 0.3 mL min(-1) with a column temperature of 35°C and detection wavelength at 223 nm. The relative response factor values of (+)-R-1-(1-Naphthyl)ethylamine, regioisomer, diastereomer isomer-1, and diastereomer isomer-2 were 1.79, 0.99, 0.89, and 0.88, respectively. The cinacalcet hydrochloride formulation sample was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal, humidity, and photolytic degradation. Cinacalcet hydrochloride was found to degrade significantly under the peroxide stress conditions. The degradation products were well-resolved from cinacalcet hydrochloride and its impurities. The peak purity test results confirmed that the cinacalcet hydrochloride peak was homogenous in all stress samples and the mass balance was found to be more than 96%, thus proving the stability-indicating power of the method. The developed method was validated according to ICH guidelines.

  14. Development and Validation of a Stability-Indicating RP-UPLC Method for the Estimation of Impurities in Cinacalcet Hydrochloride API and its Formulation

    PubMed Central

    Sunil Reddy, Pingili; Raju, Thummala Veera Raghava; Raju, Penmetsa Satyanarayana; Varma, Nadimpalli Sunil; Babu, Kondra Sudhakar

    2015-01-01

    A sensitive, stability-indicating, gradient reversed-phase ultra-performance liquid chromatography method has been developed for the quantitative estimation of cinacalcet hydrochloride impurities in active pharmaceutical ingredients and pharmaceutical formulations. Efficient chromatographic separation was achieved on an Acquity BEH Shield RP18, 100 × 2.1 mm, 1.7 µm column with the mobile phase containing pH 6.6 phosphate buffer and acetonitrile. The flow rate of the mobile phase was 0.3 mL min−1 with a column temperature of 35°C and detection wavelength at 223 nm. The relative response factor values of (+)-R-1-(1-Naphthyl)ethylamine, regioisomer, diastereomer isomer-1, and diastereomer isomer-2 were 1.79, 0.99, 0.89, and 0.88, respectively. The cinacalcet hydrochloride formulation sample was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal, humidity, and photolytic degradation. Cinacalcet hydrochloride was found to degrade significantly under the peroxide stress conditions. The degradation products were well-resolved from cinacalcet hydrochloride and its impurities. The peak purity test results confirmed that the cinacalcet hydrochloride peak was homogenous in all stress samples and the mass balance was found to be more than 96%, thus proving the stability-indicating power of the method. The developed method was validated according to ICH guidelines. PMID:26839840

  15. Analytical methods for determination of magnoflorine and saponins from roots of Caulophyllum thalictroides (L.) Michx. using UPLC, HPLC and HPTLC.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Rumalla, Chidananda Swamy; Ali, Zulfiqar; Smillie, Troy J; Khan, Ikhlas A

    2011-12-15

    Analytical methods including HPLC, UPLC and HPTLC are presented for the determination of major alkaloid and triterpene saponins from the roots of Caulophyllum thalictroides (L.) Michx. (blue cohosh) and dietary supplements claiming to contain blue cohosh. A separation by LC was achieved using a reversed phase column, PDA with ELS detection, and ammonium acetate/acetonitrile gradient as the mobile phase. Owing to their low UV absorption, the triterpene saponins were detected by evaporative light scattering. The eight triterpene saponins (cauloside H, leonticin D, cauloside G, cauloside D, cauloside B, cauloside C, cauloside A and saponin PE) and the alkaloid magnoflorine could be separated within 35 min using HPLC method and within 8.0 min using UPLC method with detection limits of 10 μg/mL for saponins and 1 μg/mL for magnoflorine. The detection wavelength was 320 nm for magnoflorine and ELS detection was used for the eight saponins. The methods were also successfully applied to analyze different dietary supplements. For the products claiming to contain blue cohosh, there was a significant variability in the amounts of triterpene saponins detected. Calculations based on the analysis results for dietary supplements showed that maximum daily intake of alkaloid and saponins vary with the form (solids/liquids) and recommended doses according to the products label. Intakes varied from 0.57 to 15.8 mg/day for magnoflorine and from 5.97 to 302.4 mg/day for total saponins. LC-mass spectrometry coupled with electrospray ionization (ESI) method is described for the identification and confirmation of nine compounds in plant samples and dietary products. A HPTLC method was also developed for the fast chemical fingerprint analysis of C. thalictroides samples.

  16. EtG and EtS in Autopsy Blood Samples With and Without Putrefaction Using UPLC-MS-MS.

    PubMed

    Hegstad, Solfrid; Kristoffersen, Lena; Liane, Veronica H; Spigset, Olav

    2017-03-01

    Analytical challenges related to postmortem specimens are well known. The degree of putrefaction of the corpse will influence the quality of the blood samples, and both the efficiency of sample preparation and the subsequent chromatographic performance can be affected. An ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method was developed and validated for the determination of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in postmortem whole blood. Sample preparation prior to UPLC-MS-MS analysis consisted of protein precipitation and filtration through a phospholipid removal plate. Chromatography was achieved using an HSS T3 column and gradient elution with formic acid in water in combination with methanol. The injection volume was 0.5 µL. Negative electrospray ionization was performed in the multiple reaction monitoring mode. Two transitions were monitored for the analytes and one for the internal standards. The between-assay relative standard deviations were in the range of 1.7-7.0% and the limits of quantification were 0.025 and 0.009 mg/L for EtG and EtS, respectively. Recovery was 51-55% and matrix effects ranged from 98% to 106% (corrected with internal standard). Blood samples from nine autopsy cases with various extents of putrefaction were analyzed. The sample preparation efficiently removed the phospholipids from the blood specimens. The samples were clean and the analytical quality of the chromatographic performance was satisfactory for both analytes irrespective of the degree of putrefaction.

  17. Column Liquid Chromatography.

    ERIC Educational Resources Information Center

    Majors, Ronald E.; And Others

    1984-01-01

    Reviews literature covering developments of column liquid chromatography during 1982-83. Areas considered include: books and reviews; general theory; columns; instrumentation; detectors; automation and data handling; multidimensional chromatographic and column switching techniques; liquid-solid chromatography; normal bonded-phase, reversed-phase,…

  18. Identification of ginsenoside markers from dry purified extract of Panax ginseng by a dereplication approach and UPLC-QTOF/MS analysis.

    PubMed

    Yang, Heejung; Lee, Dong Young; Kang, Kyo Bin; Kim, Jeom Yong; Kim, Sun Ok; Yoo, Young Hyo; Sung, Sang Hyun

    2015-05-10

    A dry purified extract of Panax ginseng (PEG) was prepared using a manufacturing process that includes column chromatography, acid hydrolysis, and an enzyme reaction. During the manufacturing process, the more polar ginsenosides were altered into less polar forms via cleavage of their sugar chains and structural modifications of the aglycones, such as hydroxylation and dehydroxylation. The structural changes of ginsenosides during the intermediate steps from dried ginseng extract (DGE) to PEG were monitored by ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectroscopy (UPLC-QTOF/MS). 22 ginsenosides isolated from PEG were used as the reference standards for determining of unknown ginsenosides and further suggesting of the metabolic markers. The elution order of 22 ginsenosides based on the type of aglycones, and the location and number of sugar chains can be used for the structural elucidation of unknown ginsenosides. This information could be used in a dereplication process for quick and efficient identification of ginsenoside derivatives in ginseng preparations. A dereplication approach helped the identification of the metabolic markers in the UPLC-QTOF/MS chromatograms during the conversion process with multivariate analyses, including principal component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA) plots. These metabolic markers were identified by comparing with the dereplication information of the reference standards of 22 ginsenosides, or they were assigned using the pattern of the MS/MS fragmented ions. Consequently, the developed metabolic profiling approach using UPLC-QTOF/MS and multivariate analysis represents a new method for providing quality control as well as useful criteria for a similarity evaluation of the manufacturing process of ginseng preparations.

  19. A Rapid, Stability Indicating RP-UPLC Method for Simultaneous Determination of Ambroxol Hydrochloride, Cetirizine Hydrochloride and Antimicrobial Preservatives in Liquid Pharmaceutical Formulation

    PubMed Central

    Trivedi, Rakshit Kanubhai; Patel, Mukesh C.; Jadhav, Sushant B.

    2011-01-01

    A stability indicating reversed phase ultra performance liquid chromatography (RP-UPLC) method was developed for simultaneous determination of ambroxol hydrochloride (AMB), cetirizine hydrochloride (CTZ), methylparaben (MP) and propylparaben (PP) in liquid pharmaceutical formulation. The desired chromatographic separation was achieved on an Agilent Eclipse plus C18, 1.8 μm (50 × 2.1 mm) column using gradient elution at 237 nm detector wavelength. The optimized mobile phase consists of a mixture of 0.01 M phosphate buffer and 0.1 % triethylamine as a solvent-A and acetonitrile as a solvent-B. The developed method separates AMB, CTZ, MP and PP in presence of twelve known impurities/degradation products and one unknown degradation product within 3.5 min. Stability indicating capability was established by forced degradation experiments and seperation of known and unknown degradation products. The lower limit of quantification was established for AMB, CTZ, MP and PP. The developed RP-UPLC method was validated according to the International Conference on Harmonization (ICH) guidelines. This validated method is applied for simultaneous estimation of AMB, CTZ, MP and PP in commercially available syrup samples. Further, the method can be extended for estimation of AMB, CTZ, MP, PP and levo-cetirizine (LCTZ) in various commercially available dosage forms. PMID:21886901

  20. Validation of a confirmatory method of salbutamol in sheep hair by UPLC-MS/MS and its application to pharmacokinetic study.

    PubMed

    Decheng, Suo; Wei, Zhang; Yu, Zhang; Genlong, Zhao; Ruigou, Wang; PeiLong, Wang; Xiaoou, Su

    2015-10-10

    A new method for determining salbutamol in hair of sheep by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was established. Samples were extracted with 0.1M of HCl solution. The mixture was heated to 60 °C in a water bath and kept at this temperature for 4h. The extracts were purified through SPE method and then dried with nitrogen. Residues were redissolved in mobile phase. The target compound was determined by UPLC-MS/MS with BEH-C18 column. The usefulness and feasibility of different treatment procedures of hair containing salbutamol were evaluated. The range of linearity was 1-100 ng/g. The LOD was 0.3 ng/g, and the LOQ was 1 ng/g. Recoveries were 89-106%, and coefficients of variation were 3.2-13.9%. Pharmacokinetics of salbutamol was studied in healthy sheep after oral administration of 150 μg/kg body weight salbutamol for 21 consecutive days. Salbutamol residues in hair were still detected after 21 days of administration.

  1. Determination of polyphenols in Mentha longifolia and M. piperita field-grown and in vitro plant samples using UPLC-TQ-MS.

    PubMed

    Krzyzanowska, Justyna; Janda, Bogdan; Pecio, Lukasz; Stochmal, Anna; Oleszek, Wieslaw; Czubacka, Anna; Przybys, Marcin; Doroszewska, Teresa

    2011-01-01

    Nine polyphenols in the aerial parts of Mentha longifolia have been separated by chromatographic techniques. Their structures have been confirmed by HPLC/electrospray ionization-MS/MS. The compounds identified included rosmarinic acid, salvianolic acid L, dedihydro-salvianolic acid, luteolin-glucuronide, luteolin-diglucuronide, luteolin-glucopyranosyl-rhamnopyranoside, and eriodictyol-glucopyranosyl-rhamnopyranoside. The extracts of M. longifolia and M. piperita field plants, in vitro plants, callus tissues, and cell suspension cultures were profiled, and their polyphenol composition was compared in different tissues and quantified using ultra-performance column liquid chromatography (UPLC)/triple-quadrupole-MS in the selected-ion recording detection mode. Determination of desired compounds was based on calibration curves obtained for standards, which were previously isolated from M. longifolia aerial parts. The UPLC profiles revealed considerable differences in the synthesis of secondary metabolites among samples coming from field plants, in vitro plants, callus tissues, and cell suspension cultures. Plant tissues coming from field cultivation (for both M. piperita and M. longifolia) contained several phenolic compounds (flavonoids and phenolic acids), whereas plants from in vitro conditions, callus tissues, and suspension cultures contained only a few of them. Rosmarinic acid dominated in all of these samples. These results show that under in vitro conditions, the metabolism of phenolics undergoes a fundamental change.

  2. Simultaneous determination of alkaloids and flavonoids from aerial parts of Passiflora species and dietary supplements using UPLC-UV-MS and HPTLC.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Rumalla, Chidananda Swamy; Smillie, Troy J; Khan, Ikhlas A

    2012-09-01

    A rapid UPLC method was developed for the simultaneous analysis of five indole alkaloids (harmalol, harmol, harmane, harmaline and harmine) and four flavonoids (orientin, isoorientin, vitexin, and isovitexin) from the aerial parts of Passiflora incarnata L. (Passifloraceae), other species of Passiflora (P. violacea Veil., P. edulis Sims., P. suberosa L., P. morifolia Mast. and P. quadrangularis L.), Peganum harmala, and dietary supplements that claim to contain Passiflora. The separation was achieved within eight minutes by using C-18 column, a water/acetonitrile mobile phase, both containing formic acid, using a gradient system and a temperature of 35 degrees C. The method was validated for linearity, repeatability, limits of detection (LOD), and limits of quantification (LOQ). The wavelength used for quantification with the diode array detector was 340 nm for flavonoids and alkaloids. The developed method is simple, economic, fast and especially suitable for quality control analysis of flavonoids and alkaloids in plant samples and dietary supplements. The compounds (including isoschaftoside and schaftoside) in plant samples and commercial products of Passiflora were identified and confirmed by UPLC-MS. A HPTLC method was also developed for the chemical fingerprint analysis of Passiflora samples.

  3. UPLC-MS method for quantification of pterostilbene and its application to comparative study of bioavailability and tissue distribution in normal and Lewis lung carcinoma bearing mice.

    PubMed

    Deng, Li; Li, Yongzhi; Zhang, Xinshi; Chen, Bo; Deng, Yulin; Li, Yujuan

    2015-10-10

    A UPLC-MS method was developed for determination of pterostilbene (PTS) in plasma and tissues of mice. PTS was separated on Agilent Zorbax XDB-C18 column (50 × 2.1 mm, 1.8 μm) with gradient mobile phase at the flow rate of 0.2 ml/min. The detection was performed by negative ion electrospray ionization in multiple reaction monitoring mode. The linear calibration curve of PTS in mouse plasma and tissues ranged from 1.0 to 5000 and 0.50 to 500 ng/ml (r(2)>0.9979), respectively, with lowest limits of quantification (LLOQ) were between 0.5 and 2.0 ng/ml, respectively. The accuracy and precision of the assay were satisfactory. The validated method was applied to the study of bioavailability and tissue distribution of PTS in normal and Lewis lung carcinoma (LLC) bearing mice. The bioavailability of PTS (dose 14, 28 and 56 mg/kg) in normal mice were 11.9%, 13.9% and 26.4%, respectively; and the maximum level (82.1 ± 14.2 μg/g) was found in stomach (dose 28 mg/kg). The bioavailability, peak concentration (Cmax), time to peak concentration (Tmax) of PTS in LLC mice was increased compared with normal mice. The results indicated the UPLC-MS method is reliable and bioavailability and tissue distribution of PTS in normal and LLC mice were dramatically different.

  4. Separation of microcystins and nodularins by ultra performance liquid chromatography.

    PubMed

    Spoof, Lisa; Neffling, Milla-Riina; Meriluoto, Jussi

    2009-11-15

    Four ultra performance liquid chromatography (UPLC) columns with different reversed-phase characteristics were tested in the chromatographic separation of 10 microcystins and three nodularins, cyanobacterial peptide toxins. The columns had been designed by the manufacturer to withstand the ultra-high pressure generated by sub-2microm stationary phase particles and the Waters ACQUITY UPLC system in ultra-fast separations. The gradient mobile phase consisted of water and acetonitrile, both acidified with trifluoroacetic acid, with three gradient rise times: 1, 1.5 and 2min. The UV detection of the toxins was performed by a photodiode array detector. The chromatographic performance was evaluated both visually and by calculating chromatographic parameters such as capacity factor, resolution, peak width at half height, selectivity and peak asymmetry. The best chromatographic performance as judged by visual inspection was given by the ACQUITY BEH Shield RP18 and ACQUITY BEH Phenyl columns. The BEH Shield RP18 column showed excellent selectivity and resolution of chosen peak pairs considered as critical. A further advantage of the UPLC system was the high sample throughput with a total analysis time of 3.12min (injection-to-injection) equalling to 461 separations per 24h.

  5. Inelastic column behavior

    NASA Technical Reports Server (NTRS)

    Duberg, John E; Wilder, Thomas W , III

    1952-01-01

    The significant findings of a theoretical study of column behavior in the plastic stress range are presented. When the behavior of a straight column is regarded as the limiting behavior of an imperfect column as the initial imperfection (lack of straightness) approaches zero, the departure from the straight configuration occurs at the tangent-modulus load. Without such a concept of the behavior of a straight column, one is led to the unrealistic conclusion that lateral deflection of the column can begin at any load between the tangent-modulus value and the Euler load, based on the original elastic modulus. A family of curves showing load against lateral deflection is presented for idealized h-section columns of various lengths and of various materials that have a systematic variation of their stress-strain curves.

  6. Distillation Column Modeling Tools

    SciTech Connect

    2001-09-01

    Advanced Computational and Experimental Techniques will Optimize Distillation Column Operation. Distillation is a low thermal efficiency unit operation that currently consumes 4.8 quadrillion BTUs of energy...

  7. A rapid and simple UPLC-MS-MS method for determination of glipizide in human plasma and its application to bioequivalence study.

    PubMed

    Qiu, Xiangjun; Zheng, Shuang-li; Wang, Yingfei; Wang, Rong; Ye, Lei

    2015-01-01

    In this study, a simple, rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry method is described for the determination of glipizide in human plasma samples using carbamazepine as the internal standard (IS) from bioequivalence assays. Sample preparation was accomplished through protein precipitation with methanol, and chromatographic separation was performed on an Acquity BEH C18 column (2.1 mm × 50 mm, 1.7 μm) with gradient profile at a flow rate of 0.4 mL/min. Mass spectrometric analysis was performed using an QTrap5500 mass spectrometer coupled with an electrospray ionization source in the positive ion mode. The multiple reaction monitoring transitions of m/z 446.1 → 321.0 and m/z 237.1 → 194.2 were used to quantify for glipizide and IS. The linearity of this method was found to be within the concentration range of 10-1,500 ng/mL for glipizide in human plasma. Only 1.0 min was needed for an analytical run. The method was applied to a bioequivalence study of two drug products containing glipizide in human plasma samples.

  8. Development and validation of a sensitive UPLC-MS/MS method for the analysis of narcotic analgesics in urine and whole blood in forensic context.

    PubMed

    Verplaetse, Ruth; Tytgat, Jan

    2012-02-10

    Narcotic analgesics are widely (ab) used and sometimes only occur in low concentrations in biological samples. Therefore, a highly sensitive liquid chromatography tandem mass spectrometry method was developed for simultaneous analysis of 9 narcotic analgesics and metabolites (buprenorphine, O-desmethyltramadol, fentanyl, norbuprenorphine, norfentanyl, pethidine, piritramide, tilidine and tramadol) in urine and whole blood. Sample preparation was performed on a mixed-mode cation exchange solid phase extraction cartridge with an additional alkaline wash step to decrease matrix effects and thus increase sensitivity. Ionization with electrospray ionization was found to be more efficient than atmospheric pressure chemical ionization. The use of a mobile phase of high pH resulted in higher electrospray ionization signals than the conventional low pH mobile phases. In the final method, gradient elution with 10mM ammonium bicarbonate (pH 9) and methanol was performed on a small particle column (Acquity C18, 1.7 μm, 2.1 mm × 50 mm). Selectivity, matrix effects, recovery, linearity, sensitivity, precision, accuracy and stability were validated in urine and whole blood. All parameters were successfully evaluated and the method showed very high sensitivity, which was the major aim of this study. The applicability of the method was demonstrated by analysis of several forensic cases involving narcotic analgesics.

  9. Development and validation of a simple, sensitive, selective and stability-indicating RP-UPLC method for the quantitative determination of ritonavir and its related compounds.

    PubMed

    Koppala, Srinivasarao; Panigrahi, Bibhuranjan; Raju, S V N; Padmaja Reddy, K; Ranga Reddy, V; Anireddy, Jaya Shree

    2015-01-01

    A simple, sensitive, selective and reproducible stability-indicating ultra-performance liquid chromatographic method was developed for the quantitative determination of degradation products and process-related impurities of Ritonavir in a pharmaceutical dosage form. Chromatographic separation was achieved on a polar embedded Waters Acquity BEH Shield RP18 (100 × 2.1 mm, 1.7 μm) column thermostated at 50°C under gradient elution by using a binary mixture of potassium dihydrogen phosphate (0.01 M, pH 3.5) and acetonitrile at a flow rate of 0.5 mL/min. Chromatogram was monitored at 240 nm using a photodiode array detector. The drug and its related impurities are eluted within 20 min. To prove the stability-indicating power of the method, the drug was subjected to hydrolytic (acid, alkaline and water), oxidative, photolytic and thermal stress conditions. The unknown degradants were identified by the LC-MS-MS method, which revealed protonated molecular ion peaks [M + H](+) at m/z 551.40 for hydrolytic degradants, and m/z 737.60 and m/z 753.40 for photolytic degradants. A plausible mechanism for the formation of degradation and process impurities was proposed. The performance of the method was validated according to the International Conference on Harmonization guidelines.

  10. Screening analysis for medicinal drugs and drugs of abuse in whole blood using ultra-performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS)--toxicological findings in cases of alleged sexual assault.

    PubMed

    Birkler, Rune Isak Dupont; Telving, Rasmus; Ingemann-Hansen, Ole; Charles, Annie Vesterby; Johannsen, Mogens; Andreasen, Mette Findal

    2012-10-10

    An ultra-performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) method for simultaneous screening of 46 medicinal drugs and drugs of abuse in whole blood was developed and validated. The method includes most of the commonly used and abused drugs such as amphetamines, cocaine, benzodiazepines, and opioids. Chromatographic separation of the targeted drugs was achieved using a Waters ACQUITY UPLC coupled to a Waters Micromass LCT Premier XE time-of-flight mass spectrometer. The total chromatographic run time was 13.5 min injection to injection. The estimated method LOQ is in the range of 0.06-27 ng/g, which is below the therapeutic levels for each of the drugs analyzed but LSD. The extraction recovery ranged from 6% to 197% with median value 95% and mean value 82%. Matrix effect ranged from 81% suppression to 29% enhancement of the signals compared to signals obtained in the absence of biological matrix. The method was tested on 55 authentic forensic toxicology samples confirming the same positive results as found using the routine analytical procedures as well as some additional compounds. Recently there has been considerable attention paid to drug-facilitated sexual assault and the toxicological findings in these cases. As part of a pilot study to investigate the prevalence of medicinal drugs, drugs of abuse, and alcohol in victims of alleged sexual assault, biological specimens were obtained from 167 victims being examined at the Sexual Assault Center in Aarhus, Denmark. The obtained blood samples were analyzed using the novel screening method supported by additional analyses for e.g. THC and alcohol. 124 victims reported they have been drinking alcohol prior to the assault (74%). Alcohol analyses revealed 59 positive findings (48%). 35 of the cases were found positive for one or more drugs excluding alcohol (21%). 20 of the victims reported they have been subject to a drug-facilitated sexual assault (12%). For the victims suspecting drug

  11. Column flotation '88

    SciTech Connect

    Sastry, K.V.S.

    1988-01-01

    This book contains 34 selections. Some of the titles are: Column flotation of ultrafine coal: experience at BHP-Utah Coal Limited's Riverside mine; Measurement of rate data in flotation columns; Factors influencing the structure of a 3-phase coal flotation froth; and Microbubble flotation of fine coal.

  12. Inflatable Column Structure

    NASA Technical Reports Server (NTRS)

    Hedgepeth, J. M.

    1985-01-01

    Lightweight structural member easy to store. Billowing between circumferential loops of fiber inflated column becomes series of cells. Each fiber subjected to same tension along entire length (though tension is different in different fibers). Member is called "isotensoid" column. Serves as jack for automobiles or structures during repairs. Also used as support for temporary bleachers or swimming pools.

  13. Measuring Ochratoxin A Concentrations in Coffee Beverages with Immunoaffinity Columns and Ultra-Performance Liquid Chromatography/Tandem Mass Spectrometry.

    PubMed

    Chen, Wen-Ling; Chang, Chiung-Wen; Chen, Chia-Yang

    2016-01-01

    This study developed and validated a method for measuring concentrations of ochratoxin A (OTA) in coffee beverages, not coffee beans. The new method involved extraction using immunoaffinity columns and ultra-performance LC (UPLC)-MS/MS using isotope-dilution techniques. The combination of a fused-core column and UPLC significantly shortened chromatographic time to 3 min compared to reported UPLC methods. The method was sensitive, with an LOD and LOQ of 0.52 and 1.73 pg/mL, respectively. Quantitative intraday (n = 4) and interday (n = 4) biases and RSD were both below 15%. The OTA levels in 40 samples of freshly brewed coffee from chain stores, 24 samples of canned ready-to-drink coffee, and 6 beverages made from instant coffee granules ranged from 1.60 to 93.2 pg/mL (90% positive), 6.00 to 131 pg/mL (100% positive), and 21.8 to 59.0 pg/mL (100% positive), respectively. Based on published tolerable daily intake, men and women in Taiwan should consume no more than 6.3 and 5.1 fifteen gram packages of instant coffee per day, respectively. Specific suggestions were not made for brewed coffee and canned coffee because of their large variation in OTA concentrations. This study should be more relevant to actual human exposure than those studying OTA in green, roasted, and ground coffee beans alone.

  14. Modeling of column flotation

    SciTech Connect

    Luttrell, G.H.; Adel, G.T.; Yoon, R.H.

    1987-01-01

    Many investigators believe that column flotation cells offer significant advantages over standard mechanical machines for the flotation of fine particles. However, because of their unique design and operation, conventional techniques for flotation cell scale-up and design cannot be applied to columns. In an attempt to help alleviate this problem, a population balance model based on first principles has been developed for fine particle flotation in a column. Two different terms have been considered in the model, i.e., transport and rate. Transport terms, incorporating fluid flow and buoyancy, are used to describe the movement of air bubbles, unattached particles and bubble-particle aggregates along the length of the column. Rate terms, which describe the bubble-particle attachment process, have been derived from first principle considerations. Because the model is based on first principles, it can be useful for the design, control, optimization and scale-up of column flotation cells. 9 refs., 12 figs.

  15. Glass-silicon column

    DOEpatents

    Yu, Conrad M.

    2003-12-30

    A glass-silicon column that can operate in temperature variations between room temperature and about 450.degree. C. The glass-silicon column includes large area glass, such as a thin Corning 7740 boron-silicate glass bonded to a silicon wafer, with an electrode embedded in or mounted on glass of the column, and with a self alignment silicon post/glass hole structure. The glass/silicon components are bonded, for example be anodic bonding. In one embodiment, the column includes two outer layers of silicon each bonded to an inner layer of glass, with an electrode imbedded between the layers of glass, and with at least one self alignment hole and post arrangement. The electrode functions as a column heater, and one glass/silicon component is provided with a number of flow channels adjacent the bonded surfaces.

  16. JCE Feature Columns

    NASA Astrophysics Data System (ADS)

    Holmes, Jon L.

    1999-05-01

    The Features area of JCE Online is now readily accessible through a single click from our home page. In the Features area each column is linked to its own home page. These column home pages also have links to them from the online Journal Table of Contents pages or from any article published as part of that feature column. Using these links you can easily find abstracts of additional articles that are related by topic. Of course, JCE Online+ subscribers are then just one click away from the entire article. Finding related articles is easy because each feature column "site" contains links to the online abstracts of all the articles that have appeared in the column. In addition, you can find the mission statement for the column and the email link to the column editor that I mentioned above. At the discretion of its editor, a feature column site may contain additional resources. As an example, the Chemical Information Instructor column edited by Arleen Somerville will have a periodically updated bibliography of resources for teaching and using chemical information. Due to the increase in the number of these resources available on the WWW, it only makes sense to publish this information online so that you can get to these resources with a simple click of the mouse. We expect that there will soon be additional information and resources at several other feature column sites. Following in the footsteps of the Chemical Information Instructor, up-to-date bibliographies and links to related online resources can be made available. We hope to extend the online component of our feature columns with moderated online discussion forums. If you have a suggestion for an online resource you would like to see included, let the feature editor or JCE Online (jceonline@chem.wisc.edu) know about it. JCE Internet Features JCE Internet also has several feature columns: Chemical Education Resource Shelf, Conceptual Questions and Challenge Problems, Equipment Buyers Guide, Hal's Picks, Mathcad

  17. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    PubMed Central

    Salazar, Carolina; Armenta, Jenny M.; Shulaev, Vladimir

    2012-01-01

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The

  18. Metabolomic Analysis of Key Central Carbon Metabolism Carboxylic Acids as Their 3-Nitrophenylhydrazones by UPLC/ESI-MS

    PubMed Central

    Han, Jun; Gagnon, Susannah; Eckle, Tobias; Borchers, Christoph H.

    2014-01-01

    Multiple hydroxy-, keto-, di-, and tri-carboxylic acids are among the cellular metabolites of central carbon metabolism (CCM). Sensitive and reliable analysis of these carboxylates is important for many biological and cell engineering studies. In this work, we examined 3-nitrophenylhydrazine as a derivatizing reagent and optimized the reaction conditions for the measurement of ten CCM related carboxylic compounds, including glycolate, lactate, malate, fumarate, succinate, citrate, isocitrate, pyruvate, oxaloacetate, and α-ketoglutarate as their 3-nitrophenylhydrazones using LC/MS with electrospray ionization. With the derivatization protocol which we have developed, and using negative-ion multiple reaction monitoring on a triple-quadrupole instrument, all of the carboxylates showed good linearity within a dynamic range of ca. 200 to more than 2000. The on-column limits of detection and quantitation were from high femtomoles to low picomoles. The analytical accuracies for eight of the ten analytes were determined to be between 89.5 to 114.8% (CV≤7.4%, n=6). Using a quadrupole time-of-flight instrument, the isotopic distribution patterns of these carboxylates, extracted from a 13C-labeled mouse heart, were successfully determined by UPLC/MS with full-mass detection, indicating the possible utility of this analytical method for metabolic flux analysis. In summary, this work demonstrates an efficient chemical derivatization LC/MS method for metabolomic analysis of these key CCM intermediates in a biological matrix. PMID:23580203

  19. Identification of phospholipids classes and molecular species in different types of egg yolk by using UPLC-Q-TOF-MS.

    PubMed

    Ali, Abdelmoneim H; Zou, Xiaoqiang; Lu, Jian; Abed, Sherif M; Yao, Yunping; Tao, Guanjun; Jin, Qingzhe; Wang, Xingguo

    2017-04-15

    Egg phospholipids (PLs) are currently the products of greatest commercial interest with major area of importance in various fields. Therefore, in this study, duck, hen and quail egg yolk PLs were isolated by solvent extraction with chilled acetone precipitation, and subsequently separated and identified by using ultra-performance liquid chromatography with quadrupole-time-of-flight mass spectrometry (UPLC-Q-TOF-MS). Egg PLs were separated on hydrophilic interaction liquid chromatography (HILIC) with ethylene bridged hybrid (BEH) column by gradient elution using acetonitrile/ammonium formate as a mobile phase, and detected by mass spectrometry (MS) under electrospray ionization in positive and negative ion mode. Structural characterizations of 57 molecular species of egg yolk PLs were identified based on MS/MS fragment ion information and elemental composition in MassLynx 4.1 software. The obtained results showed that phosphatidylcholine (16:0-18:1), phosphatidylethanolamine (18:0-20:4), phosphatidylinositol (18:0-18:2), phosphatidylserine (18:0-18:2), sphingomyelin (d18:1/16:0) and lysophosphatidylcholine (16:0) were the predominant species among the different classes of egg yolk phospholipids.

  20. Interferon-alpha 2b quantification in inclusion bodies using reversed phase-ultra performance liquid chromatography (RP-UPLC).

    PubMed

    Cueto-Rojas, H F; Pérez, N O; Pérez-Sánchez, G; Ocampo-Juárez, I; Medina-Rivero, E

    2010-04-15

    Interferon-alpha 2b (IFN-alpha 2b) is a recombinant therapeutic cytokine produced as inclusion bodies using a strain of Escherichia coli as expression system. After fermentation and recovery, it is necessary to know the amount of recombinant IFN-alpha 2b, in order to determine the yield and the load for solubilization, and chromatographic protein purification steps. The present work details the validation of a new short run-time and fast sample-preparation method to quantify IFN-alpha 2b in inclusion bodies using Reversed Phase-Ultra Performance Liquid Chromatography (RP-UPLC). The developed method demonstrated an accuracy of 100.28%; the relative standard deviations for method precision, repeatability and inter-day precision tests were found to be 0.57%, 1.54% and 1.83%, respectively. Linearity of the method was assessed in the range of concentrations from 0.05 mg/mL to 0.5 mg/mL, the curve obtained had a determination coefficient (r(2)) of 0.9989. Detection and quantification limits were found to be 0.008 mg/mL and 0.025 mg/mL, respectively. The method also demonstrated robustness for changes in column temperature, and specificity against host proteins and other recombinant protein expressed in the same E. coli strain.

  1. Simultaneous determination of toltrazuril and its metabolites in chicken and pig skin+fat by UPLC-UV method.

    PubMed

    Zheng, Wenli; Jiang, Zhaoling; Zhang, Lifang; Zhang, Chong; Zhang, Xiao; Fei, Chenzhong; Zhang, Keyu; Wang, Xiaoyang; Wang, Mi; Li, Tao; Xiao, Sui; Wang, Chunmei; Xue, Feiqun

    2014-12-01

    A reliable method for the simultaneous determination of toltrazuril and its main metabolites (toltrazuril sulphone and toltrazuril sulphoxide) in chicken and pig skin+fat was developed and validated. Analytes were extracted from skin+fat with acetonitrile. The crude extracts were subjected to liquid-liquid extraction with n-hexane, and then further cleaned using primary secondary amine and Oasis™ MAX solid phase extraction cartridges. Chromatographic separation by UPLC-UV was performed on a C18+ reversed-phase column with gradient elution. Relative recovery from the spiked samples ranged from 84.8% to 109.1%. Limits of detection and quantification for the analytes were within 25-37.5μgkg(-1) and 50-75μgkg(-1), respectively. The developed method has been successfully applied to the depletion study of toltrazuril drug residues in chicken skin+fat. The recommended withdrawal period with oral administration based on our research is 24.18 days.

  2. A novel UPLC-MS/MS method for simultaneous determination of 10 effective constituents in the Jixingshizhen preparation.

    PubMed

    Cui, Kunna; Sun, Shuo; Wang, Ping; Luo, Linda; Yu, Jia; Guo, Xingjie

    2017-04-01

    A novel, reliable and reproducible UPLC-MS/MS method was developed and validated to determine simultaneously the 10 bioactive constituents (baicalin, baicalein, wogonoside, wogonin, luteoloside, dictamnine, fraxinellone, obacunone, geniposidic acid and glycyrrhizic acid) in Jixingshizhen (JXSZ) preparation. Briefly, chromatographic separation was achieved on a Waters BEH C18 column with gradient elution employing a mobile phase composed of acetonitrile and 0.1% formic acid at a flow rate of 0.3 mL/min. All analytes containing internal standard (verapamil) were detected without interference in the multiple reaction monitoring mode with positive electrospray ionization. Further, a comprehensive validation of the method was rigorously executed according to the guidelines of the International Conference on Harmonization and Chinese Pharmacopoeia (2015 Edition). The results indicated that the validated method afforded desired linearity, precision, accuracy, sensitivity and stability. At length, the newly established method was successfully applied to quantify the 10 effective ingredients in JXSZ granules from different production batches, indicating the proposed method in this paper was particularly preferable for the routine analysis of JXSZ preparation as well as the quality control, particularly in situations where high sample throughput and fast analytical speed are required.

  3. Distillation Column Flooding Predictor

    SciTech Connect

    George E. Dzyacky

    2010-11-23

    The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid

  4. Nuclear reactor control column

    DOEpatents

    Bachovchin, Dennis M.

    1982-01-01

    The nuclear reactor control column comprises a column disposed within the nuclear reactor core having a variable cross-section hollow channel and containing balls whose vertical location is determined by the flow of the reactor coolant through the column. The control column is divided into three basic sections wherein each of the sections has a different cross-sectional area. The uppermost section of the control column has the greatest cross-sectional area, the intermediate section of the control column has the smallest cross-sectional area, and the lowermost section of the control column has the intermediate cross-sectional area. In this manner, the area of the uppermost section can be established such that when the reactor coolant is flowing under normal conditions therethrough, the absorber balls will be lifted and suspended in a fluidized bed manner in the upper section. However, when the reactor coolant flow falls below a predetermined value, the absorber balls will fall through the intermediate section and into the lowermost section, thereby reducing the reactivity of the reactor core and shutting down the reactor.

  5. Column continuous transition functions

    NASA Astrophysics Data System (ADS)

    Li, Yangrong

    2007-04-01

    A column continuous transition function is by definition a standard transition function P(t) whose every column is continuous for t[greater-or-equal, slanted]0 in the norm topology of bounded sequence space l[infinity]. We will prove that it has a stable q-matrix and that there exists a one-to-one relationship between column continuous transition functions and increasing integrated semigroups on l[infinity]. Using the theory of integrated semigroups, we give some necessary and sufficient conditions under which the minimal q-function is column continuous, in terms of its generator (of the Markov semigroup) as well as its q-matrix. Furthermore, we will construct all column continuous Q-functions for a conservative, single-exit and column bounded q-matrix Q. As applications, we find that many interesting continuous-time Markov chains (CTMCs), say Feller-Reuter-Riley processes, monotone processes, birth-death processes and branching processes, etc., have column continuity.

  6. A Validated Stability-Indicating RP-UPLC Method for Simultaneous Determination of Desloratadine and Sodium Benzoate in Oral Liquid Pharmaceutical Formulations

    PubMed Central

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy

    2012-01-01

    A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH2PO4 and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness. PMID:22396911

  7. A Validated Stability-Indicating RP-UPLC Method for Simultaneous Determination of Desloratadine and Sodium Benzoate in Oral Liquid Pharmaceutical Formulations.

    PubMed

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy

    2012-01-01

    A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.

  8. UPLC-MS/MS determination of florfenicol and florfenicol amine antimicrobial residues in tilapia muscle.

    PubMed

    Orlando, Eduardo Adilson; Costa Roque, Aline Gabriela; Losekann, Marcos Eliseu; Colnaghi Simionato, Ana Valéria

    2016-11-01

    Despite the benefits to fish farmers, the use of antimicrobials in aquaculture has concerned consumers and competent authorities. The indiscriminate use of such substances promotes the emergence of resistant microorganisms, decreases the effectiveness of treatments, and causes possible toxic effects in humans. In Brazil, florfenicol is the only antimicrobial registered for use in aquaculture and is often used in tilapia in cage creation. Thus, this study aimed to develop a method for determination of florfenicol residues and its metabolite florfenicol amine in tilapia fillet by UPLC-MS/MS. Analytes were extracted with ethyl acetate, followed by liquid-liquid partition clean-up with hexane and SPE. The sorbents C18, phenyl and HLB-Oasis were evaluated by SPE. Phenyl sorbent showed the best results, and the extraction conditions were optimized in the sample matrix with fractional factorial design 2(4-1). The analytes were separated on a C18 chromatographic column (50×2.1mm×1.7μm) using water (A) and acetonitrile (B) as mobile phase at a flow rate of 0.3mLmin(-1) with a linear gradient (in% B): 0-2.0min: 20%; 2.0-2.5min: increase to 90%; 2.5-3.5min: 90%; 3.0-3.5min: decrease to 20%; 4.0-5.0min: 20%. The analytes were monitored in a MS/MS triple quadrupole system by MRM mode with transitions at m/z 356.1>336.1 (florfenicol) and m/z 248.1>130.1 (florfenicol amine). The optimized method was validated obtaining LOQ values of 3 and 25ngg(-1) for florfenicol and florfenicol amine, respectively, precision between 20 and 36%, absolute extraction efficiency between 38 and 80%, and adequate linearity. The method was applied to samples intended for human consumption, and within the 15 evaluated samples, only one showed florfenicol residue at 30ngg(-1), which is below the maximum residue limit established in Brazil.

  9. Simultaneous UPLC-MS/MS analysis of native catechins and procyanidins and their microbial metabolites in intestinal contents and tissues of male Wistar Furth inbred rats.

    PubMed

    Goodrich, Katheryn M; Neilson, Andrew P

    2014-05-01

    Procyanidins have been extensively investigated for their potential health protective activities. However, the potential bioactivities of procyanidins are limited by their poor bioavailability. The majority of the ingested dose remains unabsorbed and reaches the colon where extensive microbial metabolism occurs. Most existing analytical methods measure either native compounds (catechins and procyanidins), or their microbial metabolites. The objectives of this study were to develop a high-throughput extraction and UPLC-MS/MS method for simultaneous measurement of both native procyanidins and their metabolites, facilitating high-throughput analysis of native and metabolite profiles in various regions of the colon. The present UPLC-MS/MS method facilitates simultaneous resolution and detection of authentic standards of 14 native catechin monomers and procyanidins, as well as 24 microbial metabolites. Detection and resolution of an additional 3 procyanidin dimers and 10 metabolites for which standards were not available was achieved. Elution and adequate resolution of both native compounds and metabolites were achieved within 10min. The intraday repeatability for native compounds was between 1.1 and 16.5%, and the interday repeatability for native compounds was between 2.2 and 25%. Intraday and interday repeatability for metabolites was between 0.6 and 24.1% and 1 and 23.9%, respectively. Observed lower limits of quantification for native compounds were ∼9-350fmol on-column, and for the microbial metabolites were ∼0.8-12,000fmol on-column. Observed lower limits of detection for native compounds were ∼4.5-190fmol on-column, and for metabolites were 0.304-6020fmol on-column. For native monomers and procyanidins, extraction recoveries ranged from 38 to 102%. Extraction recoveries for the 9 microbial metabolites tested ranged from 41 to 95%. Data from tissue analysis of rats gavaged with grape seed extract indicate fairly high accumulation of native compounds

  10. An integrated strategy using UPLC-QTOF-MS(E) and UPLC-QTOF-MRM (enhanced target) for pharmacokinetics study of wine processed Schisandra Chinensis fructus in rats.

    PubMed

    Liu, Kuangyi; Song, Yonggui; Liu, Yali; Peng, Mi; Li, Hanyun; Li, Xueliang; Feng, Bingwei; Xu, Pengfei; Su, Dan

    2017-02-27

    Currently the pharmacokinetic (PK) research of herbal medicines is still limited and facing critical technical challenges on quantitative analysis of multi-components from biological matrices which often accompanied by lacking of authentic standards and low concentration. This present work contributes to the development of an integrated strategy for extensive pharmacokinetics assessments, and a selective and sensitive method independent of authentic standards for multi-components analysis based on the use of ultra-performance liquid chromatography/quadrupole-time-of-flight/MS(E) (UPLC-TOF-MS(E)) and UPLC-TOF-MRM (rnhanced target). Initially, phytochemicals were identified by UPLC-TOF-MS(E) analysis, subsequently the identified components were matched with authentic standards and pre-classified, and UPLC-QTOF-MRM method optimized and developed. To guarantee reliable results, three rules are necessary: (1) detection with a mass error of less than 5ppm; (2) same class chemical compositions with structural high similarity between analytes with and without authentic reference substance; (3) a matching retention time between TOF-MRM mode and TOF-MS(E) within 0.2min. The developed and validated method was applied for the simultaneous determination of 12 lignans in rat plasma after administered with wine processed Schisandra Chinensis fructus (WPSCF) extract. Such an approach was found capable of providing extensive pharmacokinetic profiles of multi-components absorbed into blood after oral administrated with WPSCF extract. The results also indicated that significant difference in pharmacokinetics parameters of dibenzocyclooctadiene lignans was observed between schizandrin and gomisin compounds. For lignans, the absorption via gastrointestinal tract were all rapid and maintained relatively long retention time, especially for schisantherin A and schisantherin B with higher plasma exposure.

  11. Eruption column physics

    SciTech Connect

    Valentine, G.A.

    1997-03-01

    In this paper the author focuses on the fluid dynamics of large-scale eruption columns. The dynamics of these columns are rooted in multiphase flow phenomena, so a major part of the paper sets up a foundation on that topic that allows one to quickly assess the inherent assumptions made in various theoretical and experimental approaches. The first part is centered on a set of complex differential equations that describe eruption columns, but the focus is on a general understanding of important physical processes rather than on the mathematics. The author discusses briefly the relative merits and weaknesses of different approaches, emphasizing that the largest advances in understanding are made by combining them. He then focuses on dynamics of steady eruption columns and then on transient phenomena. Finally he briefly reviews the effects of varying behavior of the ambient medium through which an eruption column moves. These final sections will emphasize concepts and a qualitative understanding of eruption dynamics. This paper relies on principles of continuum mechanics and transport processes but does not go into detail on the development of those principles. 36 refs., 36 figs., 3 tabs.

  12. Determination of anthelmintic drug residues in milk using UPLC-MS/MS with rapid polarity switching

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A new UPLC-MS/MS (ultra-performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added...

  13. Chemical Fingerprint Analysis and Quantitative Analysis of Rosa rugosa by UPLC-DAD.

    PubMed

    Mansur, Sanawar; Abdulla, Rahima; Ayupbec, Amatjan; Aisa, Haji Akbar

    2016-12-21

    A method based on ultra performance liquid chromatography with a diode array detector (UPLC-DAD) was developed for quantitative analysis of five active compounds and chemical fingerprint analysis of Rosa rugosa. Ten batches of R. rugosa collected from different plantations in the Xinjiang region of China were used to establish the fingerprint. The feasibility and advantages of the used UPLC fingerprint were verified for its similarity evaluation by systematically comparing chromatograms with professional analytical software recommended by State Food and Drug Administration (SFDA) of China. In quantitative analysis, the five compounds showed good regression (R² = 0.9995) within the test ranges, and the recovery of the method was in the range of 94.2%-103.8%. The similarities of liquid chromatography fingerprints of 10 batches of R. rugosa were more than 0.981. The developed UPLC fingerprint method is simple, reliable, and validated for the quality control and identification of R. rugosa. Additionally, simultaneous quantification of five major bioactive ingredients in the R. rugosa samples was conducted to interpret the consistency of the quality test. The results indicated that the UPLC fingerprint, as a characteristic distinguishing method combining similarity evaluation and quantification analysis, can be successfully used to assess the quality and to identify the authenticity of R. rugosa.

  14. Antihepatotoxic Effect and Metabolite Profiling of Panicum turgidum Extract via UPLC-qTOF-MS

    PubMed Central

    Farag, Mohamed A.; El Fishawy, Ahlam M.; El-Toumy, Sayed A.; Amer, Khadiga F.; Mansour, Ahmed M.; Taha, Hala E.

    2016-01-01

    Background: Panicum turgidum, desert grass, has not reported any detailed phytochemical or biological study as yet Objective: To establish P. turgidum secondary metabolite profile and to assess its antihepatotoxic effect Materials and Methods: Ultra-performance liquid chromatography (UPLC) coupled to quadrupole high-resolution time of flight mass spectrometry (qTOF-MS) was used for large-scale secondary metabolites profiling in P. turgidum extract, alongside assessing median lethal dose (LD50) and hepatoprotective effect against carbon tetrachloride (CCl4) intoxication Results: A total of 39 metabolites were identified with flavonoids as the major class present as O/C-glycosides of luteolin, apigenin, isorhamnetin and naringenin, most of which are first time to be reported in Panicum sp. Antihepatotoxic effect of P. turgidum crude extract was revealed via improving several biochemical marker levels and mitigation against oxidative stress in the serum and liver tissues, compared with CCl4 intoxicated group and further confirmed by histopathological examination. Conclusion: This study reveals that P. turgidum, enriched in C-flavonoids, presents a novel source of safe antihepatotoxic agents and further demonstrates the efficacy of UPLC-MS metabolomics in the field of natural products drug discovery. SUMMARY UPLC coupled to qTOF-MS was used for large scale secondary metabolites profiling in P. turgidum.A total of 39 metabolites were identified with flavonoids amounting as the major metabolite class.Anti-hepatotoxic effect of P. turgidum extract was revealed via several biochemical markers and histopathological examination.This study reveals that P. turgidum, enriched in C-flavonoids, present a novel source of antihepatotoxic agents. Abbreviations used: UPLC: Ultra-performance liquid chromatography (UPLC), LD50: median lethal dose, MDA: malondialdehyde, GSH: glutathione reductase, CAT: catalase, SOD: superoxide dismutase, ALT: alanine aminotransferase, AST: aspartate

  15. Columns in Clay

    ERIC Educational Resources Information Center

    Leenhouts, Robin

    2010-01-01

    This article describes a clay project for students studying Greece and Rome. It provides a wonderful way to learn slab construction techniques by making small clay column capitols. With this lesson, students learn architectural vocabulary and history, understand the importance of classical architectural forms and their influence on today's…

  16. Preparation and characterization of an immunoaffinity column for the selective extraction of aflatoxin B1 in 13 kinds of foodstuffs.

    PubMed

    Xie, Jie; Peng, Tao; He, Jian-Li; Shao, Yu; Fan, Chun-Lin; Chen, Ying; Jiang, Wen-Xiao; Chen, Min; Wang, Qi; Pei, Xing-Yao; Ding, Shuang-Yang; Jiang, Hai-Yang

    2015-08-15

    A rapid and reliable immunoaffinity column (IAC) clean-up based ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of aflatoxin B1 (AFB1) in cereals, peanuts, vegetable oils and Chinese traditional food products like sufu and lobster sauce. The immunoaffinity column of AFB1 (AFB1-IAC) was prepared by coupling CNBr-activated Sepharose-4B with the anti-AFB1 monoclonal antibody. The column capacity of IAC was over 260ng/mL gel. Samples were extracted with methanol-water (60:40, v/v) and the extracts were then purified on an AFB1-IAC before UPLC-MS/MS analysis. The average recoveries of AFB1 in spiked samples at levels of 1.0, 5.0 and 10.0μg/kg ranged from 72% to 98%, with the relative standard deviations of 1.2-9.3% (n=6). The limits of qualification ranged from 0.07 to 0.23μg/kg, which were below the MRLs of AFB1 in the matrices evaluated. In this work, the developed method was suitable for the determination of trace AFB1 residues in 13 kinds of foodstuffs.

  17. Folate analysis in foods by UPLC-MS/MS: development and validation of a novel, high throughput quantitative assay; folate levels determined in Australian fortified breads.

    PubMed

    Chandra-Hioe, Maria V; Bucknall, Martin P; Arcot, Jayashree

    2011-08-01

    An ultra-performance liquid chromatography-tandem mass spectrometry method was developed, optimised and validated for the quantification of synthetic folic acid (FA), also called pteroyl-L: -glutamic acid or vitamin B9 and naturally occurring 5-methyltetrahydrofolate (5-MTHF) found in folate-fortified breads. Optimised sample preparation prior to analysis involved addition of (13)C(5) labelled internal standards, treatments with α-amylase and rat serum, solid-phase extraction using aromatic-selective cartridges and ultra-filtration. Analytes were separated on a Waters ACQUITY HSS T3 column during a 6-min run and analysed by positive ion electrospray selected reaction monitoring MS/MS. Standard calibration curves for the two analytes were linear over the range of 0.018-14 μg FA/g of fresh bread (r(2) = 0.997) and 9.3-900 ng 5-MTHF/g of fresh bread (r(2) = 0.999). The absolute recoveries were 90% and 76% for FA and 5-MTHF, respectively. Intra-day coefficients of variation were 3% for FA and 18% for 5-MTHF. The limit of detection was 9.0 ng/g for FA and 4.3 ng/g for 5-MTHF, determined using pre-extracted tapioca starch as the blank matrix. The assay is rugged, fast, accurate and sensitive, applicable to a variety of food matrices and is capable of the detection and quantification of the naturally occurring low levels of 5-MTHF in wheat breads. The findings of this study revealed that the FA range in Australian fortified breads was 79-110 μg/100 g of fresh bread and suggest that the flour may not have the mandated FA fortification level (200-300 μg/100 g of flour), though this cannot be determined conclusively from experimental bread data alone, as variable baking losses have been documented by other authors.

  18. Development of UPLC Fingerprint with Multi-Component Quantitative Analysis for Quality Consistency Evaluation of Herbal Medicine “Hyangsapyeongwisan”

    PubMed Central

    Sharma, Dipak Kumar; Kim, Se-Gun; Lamichhane, Ramakanta; Lee, Kyung-Hee; Poudel, Amrit; Jung, Hyun-Ju

    2016-01-01

    Hyangsapyeongwisan (HSPWS), known as traditional herbal medicine, has been used in the treatment of gastric disease. Standardization of HSPWS is a necessary step for the establishment of a consistent biological activity for the production and manufacturing of HSPWS herbal preparations. A simple, sensitive and accurate method using ultra-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed and validated for systematic quality evaluation of HSPWS. Separation conditions were optimized using a Halo C18 2.7 µm, 4.6 × 100 mm column with a mobile phase of 0.1% phosphoric acid and acetonitrile, and detection wavelengths of 215, 250 and 350 nm. Validation of the analytical method was evaluated by tests of linearity, precision, accuracy and robustness. All calibration curves of components showed good linearity (R2 > 0.9996). The limit of detection (LOD) and limit of quantification (LOQ) were within the ranges of 0.004–0.134 and 0.012–0.406 µg/mL, respectively. The relative standard deviation (RSD) values of intra- and inter-day testing were within the range of 0.01–3.84%. The result of the recovery test was 96.82–104.62% with an RSD value of 0.14–3.84%. Robustness values of all parameters as well as the stability test of analytical solutions were within the standard limit. It showed that the developed method was simple, specific, sensitive, accurate, precise, reproducible and robust for the quantification of active components of HSPWS. Chromatographic fingerprinting with quantitative analysis of marker compounds in HSPWS prepared by different methods and commercial formulation was also evaluated successfully. PMID:26711584

  19. Ultrasound-assisted hydrolysis of conjugated parabens in human urine and their determination by UPLC-MS/MS and UPLC-HRMS.

    PubMed

    Schlittenbauer, Linda; Seiwert, Bettina; Reemtsma, Thorsten

    2016-02-01

    Parabens are preservatives widely used in personal care products, pharmaceutical formulations as well as in food, and they are considered endocrine disruptors. For application in biomonitoring studies we developed a method for the determination of eight parabens from human urine. Sample preparation was enhanced and simplified by the combination of ultrasound-assisted enzymatic hydrolysis of conjugates (glucuronide and sulfate) followed by an extraction-free cleanup step. Quantification, using deuterated parabens as internal standards, was performed by ultrahigh-performance liquid chromatography coupled to either triple-quadrupole (UPLC-QqQ) or time-of-flight (UPLC-QqTOF) mass spectrometry. Full chromatographic separation of three butyl paraben isomers was achieved. Limits of quantification for both mass analyzers ranged from 0.1 to 0.5 μg/L for methyl, ethyl, n-/isopropyl, n-/isobutyl, and benzyl paraben in 200 μL of urine sample. The method was tested for applicability and showed high precision (intra- and interday 0.9-14.5%) as well as high accuracy (relative recovery 95-132%). A total of 39 urine samples were analyzed by both mass analyzers. The results agreed well, with a trend to higher deviation at low concentrations (less than 10 μg/L). Methyl, ethyl, and n-propyl paraben were detected most frequently (in more than 87% of the samples) with median concentrations ranging from 0.8 to 16.6 μg/L. Female urine showed higher median concentrations for all parabens, which may indicate higher exposure due to lifestyle. This method permits accurate and high-throughput analysis of parabens for epidemiological studies. Further, the UPLC-QqTOF approach provides additional information on human exposure to other compounds by post-acquisition analysis.

  20. Slurry bubble column hydrodynamics

    NASA Astrophysics Data System (ADS)

    Rados, Novica

    Slurry bubble column reactors are presently used for a wide range of reactions in both chemical and biochemical industry. The successful design and scale up of slurry bubble column reactors require a complete understanding of multiphase fluid dynamics, i.e. phase mixing, heat and mass transport characteristics. The primary objective of this thesis is to improve presently limited understanding of the gas-liquid-solid slurry bubble column hydrodynamics. The effect of superficial gas velocity (8 to 45 cm/s), pressure (0.1 to 1.0 MPa) and solids loading (20 and 35 wt.%) on the time-averaged solids velocity and turbulent parameter profiles has been studied using Computer Automated Radioactive Particle Tracking (CARPT). To accomplish this, CARPT technique has been significantly improved for the measurements in highly attenuating systems, such as high pressure, high solids loading stainless steel slurry bubble column. At a similar set of operational conditions time-averaged gas and solids holdup profiles have been evaluated using the developed Computed Tomography (CT)/Overall gas holdup procedure. This procedure is based on the combination of the CT scans and the overall gas holdup measurements. The procedure assumes constant solids loading in the radial direction and axially invariant cross-sectionally averaged gas holdup. The obtained experimental holdup, velocity and turbulent parameters data are correlated and compared with the existing low superficial gas velocities and atmospheric pressure CARPT/CT gas-liquid and gas-liquid-solid slurry data. The obtained solids axial velocity radial profiles are compared with the predictions of the one dimensional (1-D) liquid/slurry recirculation phenomenological model. The obtained solids loading axial profiles are compared with the predictions of the Sedimentation and Dispersion Model (SDM). The overall gas holdup values, gas holdup radial profiles, solids loading axial profiles, solids axial velocity radial profiles and solids

  1. Impact of the column hardware volume on resolution in very high pressure liquid chromatography non-invasive investigations.

    PubMed

    Gritti, Fabrice; McDonald, Thomas; Gilar, Martin

    2015-11-13

    The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18, 1.7 μm CSH-C18, 1.6 μm CORTECS-C18+, and 1.7 μm BEH-C4 particles was investigated. A rapid and non-invasive method based on the reduction of the system dispersion (to only 0.15 μL(2)) of an I-class Acquity system and on the corrected plate heights (for system dispersion) of five weakly retained n-alkanophenones in RPLC was proposed. Evidence for sample dispersion through the column hardware volume was also revealed from the experimental plot of the peak capacities for smooth linear gradients versus the corrected efficiency of a weakly retained alkanophenone (isocratic runs). The plot is built for a constant gradient steepness irrespective of the applied flow rates (0.01-0.30 mL/min) and column lengths (2, 3, 5, and 10 cm). The volume variance caused by column endfittings and frits was estimated in between 0.1 and 0.7 μL(2) depending on the applied flow rate. After correction for system and hardware dispersion, the minimum reduced plate heights of short (5 cm) and narrow-bore (2.1mm i.d.) beds packed with sub-2 μm fully and superficially porous particles were found close to 1.5 and 0.7, respectively, instead of the classical h values of 2.0 and 1.4 for the whole column assembly.

  2. Evaluation of size exclusion chromatography columns packed with sub-3μm particles for the analysis of biopharmaceutical proteins.

    PubMed

    Goyon, Alexandre; Beck, Alain; Colas, Olivier; Sandra, Koen; Guillarme, Davy; Fekete, Szabolcs

    2016-11-27

    The aim of this study was to evaluate the practical possibilities and limitations of several recently introduced size exclusion chromatographic (SEC) columns of 150×4.6mm, sub-3μm (Agilent AdvanceBioSEC 2.7μm, Tosoh TSKgel UP-SW3000 2.0μm, Phenomenex Yarra SEC X-150 1.8μm and Waters Acquity BEH200 1.7μm) for the separation of biopharmaceutical proteins. For this purpose, some model proteins were tested, as well as several commercial therapeutic monoclonal antibodies (mAbs) and antibody-drug-conjugates (ADCs). Calibration curves were drawn to highlight the applicability of these new SEC columns for the separation of mAbs, ADCs and their aggregates, despite some differences in their nominal pore diameter (vary from 150 to 300Å). The kinetic performance (van Deemter curves and kinetic pots) was evaluated. Columns packed with 1.7-2.0μm particles improved the plate count by a factor of 1.5-2 compared to 2.7μm particles, which is in agreement with theoretical expectations. Finally, possible secondary hydrophobic and/or electrostatic interactions between the SEC stationary phases and biopharmaceutical proteins were systematically studied. Significant differences in nonspecific interactions were observed, with hydrophobic interactions generally exerting more influence than electrostatic interactions. The use of a novel bond chemistry with the AdvanceBioSEC column was found highly effective to limit non-specific interactions and pave the way to further improvements for column provider. At the end, the average resolutions achieved on the four sub-3μm SEC columns between monomer and dimer structures were comparable for ten approved mAbs products.

  3. Metabolic fingerprinting of Angelica sinensis during growth using UPLC-TOFMS and chemometrics data analysis

    PubMed Central

    2013-01-01

    Background The radix of Angelica sinensis is widely used as a medicinal herbal and metabolomics research of this plant during growth is necessary. Results Principal component analysis of the UPLC-QTOFMS data showed that these 27 samples could be separated into 4 different groups. The chemical markers accounting for these separations were identified from the PCA loadings plot. These markers were further verified by accurate mass tandem mass and retention times of available reference standards. The study has shown that accumulation of secondary metabolites of Angelica sinensis is closely related to the growth periods. Conclusions The UPLC-QTOFMS based metabolomics approach has great potential for analysis of the alterations of secondary metabolites of Angelica sinensis during growth. PMID:23453085

  4. Classification of illicit heroin by UPLC-Q-TOF analysis of acidic and neutral manufacturing impurities.

    PubMed

    Liu, Cuimei; Hua, Zhendong; Bai, Yanping

    2015-12-01

    The illicit manufacture of heroin results in the formation of trace levels of acidic and neutral manufacturing impurities that provide valuable information about the manufacturing process used. In this work, a new ultra performance liquid chromatography-quadrupole-time of flight mass spectrometry (UPLC-Q-TOF) method; that features high resolution, mass accuracy and sensitivity for profiling neutral and acidic heroin manufacturing impurities was developed. After the UPLC-Q-TOF analysis, the retention times and m/z data pairs of acidic and neutral manufacturing impurities were detected, and 19 peaks were found to be evidently different between heroin samples from "Golden Triangle" and "Golden Crescent". Based on the data set of these 19 impurities in 150 authentic heroin samples, classification of heroin geographic origins was successfully achieved utilizing partial least squares discriminant analysis (PLS-DA). By analyzing another data set of 267 authentic heroin samples, the developed discrimiant model was validated and proved to be accurate and reliable.

  5. [Research on UPLC-PDA fingerprint of andrographis paniculata and quantitative determination of 4 major constituents].

    PubMed

    Huang, Jing-Yi; Liu, Xiao-Lin; Zhou, Shui-Ping; Tong, Ling; Ding, Li

    2014-11-01

    Andrographis paniculata from different parts and origins were analyzed by UPLC-PDA fingerprint to provide refererice for related preparation technology. Using the peak of andrographolide as reference, 27 common peaks were identified, and digitized UPLC-PDA fingerprints for 23 batches of andrographis paniculata were established in this research. Principal component analysis (PCA) was carried out after feature extraction. The contents of andrographolide, neoandrographolide, deoxyandrographolide, dehydroandrographolide were determined by external standard method. The Plackett-Burman design combined with pareto chart was used to analyze the factors influencing the robustness of the method. It was found that the medicinal part has a more remarkable influence on the quality of andrographis paniculata than the origin. The contents of the 4 lactones the differ greatly in the different parts of andrographis paniculata, and the pH of the mobile phase is an important factor that influenced the robustness of the method.

  6. Metabolite Profiling of Justicia gendarussa Burm. f. Leaves Using UPLC-UHR-QTOF-MS.

    PubMed

    Ningsih, Indah Yulia; Purwanti, Diah Intan; Wongso, Suwidji; Prajogo, Bambang E W; Indrayanto, Gunawan

    2015-01-01

    An ultra-performance liquid chromatography ultra-high-resolution quadrupole-time-of-flight-mass spectrometry (UPLC-UHR-QTOF-MS) metabolite profiling ofxs Justicia gendarussa Burm. f. leaves was performed. PCA and HCA analyses were applied to observe the clustering patterns and inter-sample relationships. It seemed that the concentrations of Ca, P, and Cu in the soil could affect the metabolite profiles of Justicia gendarussa. Six significant metabolites were proposed.

  7. A UPLC-MS/MS approach for simultaneous determination of eight flavonoids in rat plasma, and its application to pharmacokinetic studies of Fu-Zhu-Jiang-Tang tablet in rats.

    PubMed

    Tao, Yi; Chen, Xi; Jiang, Yanhui; Cai, Baochang

    2017-03-01

    The purpose of this study is to establish and validate a UPLC-MS/MS approach to determine eight flavonoids in biological samples and apply the method to pharmacokinetic study of Fu-Zhu-Jiang-Tang tablet. A Waters BEH C18 UPLC column was employed with methanol/0.1% formic acid-water as mobile phases. The mass analysis was carried out in a triple quadrupole mass spectrometer using multiple reaction monitoring with negative scan mode. A one-step protein precipitation by methanol was used to extract the analytes from blood. Eight major flavonoids were selected as markers. Our results showed that calibration curves for 3'-hydroxypuerarin, mirificin, puerarin, 3'-methoxypuerarin, daidzin, rutin, astragalin and daidzein displayed good linear regression (r(2)  > 0.9986). The intra-day and inter-day precisions (RSD) of the eight flavonoids at high, medium and low levels were <8.03% and the bias of the accuracies ranged from -5.20 to 6.75%.The extraction recoveries of the eight flavonoids were from 91.4 to 100.5% and the matrix effects ranged from 89.8 to 103.8%. The validated approach was successfully applied to a pharmacokinetic study in Sprague-Dawley rats after oral administration of FZJT tablet. Double peaks were emerged in curves of mean plasma concentration for 3'-methoxypuerarin, which was reported for the first time.

  8. UPLC-MS/MS determination of ephedrine, methylephedrine, amygdalin and glycyrrhizic acid in Beagle plasma and its application to a pharmacokinetic study after oral administration of Ma Huang Tang.

    PubMed

    Yan, Tianhua; Fu, Qiang; Wang, Jing; Ma, Shiping

    2015-02-01

    An ultra performance liquid chromatography-mass spectrometric (UPLC-MS) method was developed to investigate the pharmacokinetic properties of ephedrine, methylephedrine, amygdalin, and glycyrrhizic acid after oral gavage of Ma Huang Tang (MHT) in Beagles. Beagle plasma samples were pretreated using liquid-liquid extraction, and chromatographic separation was performed on a C18 column using a linear gradient of water-formic acid mixture (0.1%). The pharmacokinetic parameters of ephedrine, methylephedrine, amygdalin, and glycyrrhizic acid from MHT in Beagles were quantitatively determined by UPLC with tandem mass detector. The qualitative detection of the four compounds was accomplished by selected ion monitoring in negative/positive ion modes electrospray ionization-mass spectrometry (ESI-MS). Detection was based on multiple reaction monitoring with the precursor-to-product ion transitions m/z 166.096-116.983 (ephedrine), m/z 179.034-146.087 (methylephedrine), m/z 456.351-323.074 (amygdalin), and m/z 821.606-351.062 (glycyrrhizic acid). The selectivity, sensitivity, linearity, accuracy, precision, extraction recovery, ion suppression, and stability were within the acceptable ranges. The method described was successfully applied to reveal the pharmacokinetic properties of ephedrine, methylephedrine, amygdalin, and glycyrrhizic acid after oral gavage of MHT in Beagles.

  9. UPLC-MS(E) application in disease biomarker discovery: the discoveries in proteomics to metabolomics.

    PubMed

    Zhao, Ying-Yong; Lin, Rui-Chao

    2014-05-25

    In the last decade, proteomics and metabolomics have contributed substantially to our understanding of different diseases. Proteomics and metabolomics aims to comprehensively identify proteins and metabolites to gain insight into the cellular signaling pathways underlying disease and to discover novel biomarkers for screening, early detection and diagnosis, as well as for determining prognoses and predicting responses to specific treatments. For comprehensive analysis of cellular proteins and metabolites, analytical methods of wider dynamic range higher resolution and good sensitivity are required. Ultra performance liquid chromatography-mass spectrometry(Elevated Energy) (UPLC-MS(E)) is currently one of the most versatile techniques. UPLC-MS(E) is an established technology in proteomics studies and is now expanding into metabolite research. MS(E) was used for simultaneous acquisition of precursor ion information and fragment ion data at low and high collision energy in one analytical run, providing similar information to conventional MS(2). In this review, UPLC-MS(E) application in proteomics and metabolomics was highlighted to assess protein and metabolite changes in different diseases, including cancer, neuropsychiatric pharmacology studies from clinical trials and animal models. In addition, the future prospects for complete proteomics and metabolomics are discussed.

  10. Development and validation of a sample stabilization strategy and a UPLC-MS/MS method for the simultaneous quantitation of acetylcholine (ACh), histamine (HA), and its metabolites in rat cerebrospinal fluid (CSF).

    PubMed

    Zhang, Yanhua; Tingley, F David; Tseng, Elaine; Tella, Max; Yang, Xin; Groeber, Elizabeth; Liu, Jianhua; Li, Wenlin; Schmidt, Christopher J; Steenwyk, Rick

    2011-07-15

    A UPLC-MS/MS assay was developed and validated for simultaneous quantification of acetylcholine (ACh), histamine (HA), tele-methylhistamine (t-mHA), and tele-methylimidazolacetic acid (t-MIAA) in rat cerebrospinal fluid (CSF). The biological stability of ACh in rat CSF was investigated. Following fit-for-purpose validation, the method was applied to monitor the drug-induced changes in ACh, HA, t-mHA, and t-MIAA in rat CSF following administration of donepezil or prucalopride. The quantitative method utilizes hydrophilic interaction chromatography (HILIC) Core-Shell HPLC column technology and a UPLC system to achieve separation with detection by positive ESI LC-MS/MS. This UPLC-MS/MS method does not require extraction or derivatization, utilizes a stable isotopically labeled internal standard (IS) for each analyte, and allows for rapid throughput with a 4 min run time. Without an acetylcholinesterase (AChE) inhibitor present, ACh was found to have 1.9±0.4 min in vitro half life in rat CSF. Stability studies and processing modification, including the use of AChE inhibitor eserine, extended this half life to more than 60 min. The UPLC-MS/MS method, including stabilization procedure, was validated over a linear concentration range of 0.025-5 ng/mL for ACh and 0.05-10 ng/mL for HA, t-mHA, and t-MIAA. The intra-run precision and accuracy for all analytes were 1.9-12.3% CV and -10.2 to 9.4% RE, respectively, while inter-run precision and accuracy were 4.0-16.0% CV and -5.3 to 13.4% RE, respectively. By using this developed and validated method, donepezil caused increases in ACh levels at 0.5, 1, 2, and 4h post dose as compared to the corresponding vehicle group, while prucalopride produced approximately 1.6- and 3.1-fold increases in the concentrations of ACh and t-mHA at 1h post dose, respectively, compared to the vehicle control. Overall, this methodology enables investigations into the use of CSF ACh and HA as biomarkers in the study of these neurotransmitter systems

  11. The lateral column lengthening and medial column stabilization procedures.

    PubMed

    Chi, T D; Toolan, B C; Sangeorzan, B J; Hansen, S T

    1999-08-01

    The results of medial column stabilization, lateral column lengthening, and combined medial and lateral procedures were reviewed in the treatment of adult acquired flatfoot secondary to posterior tibialis tendon insufficiency. All bony procedures were accompanied by transfer of the flexor digitorum longus tendon to the medial cuneiform or stump of the posterior tibialis tendon and tendoachilles lengthening or gastrocnemius recession. Medial column fusion was performed for naviculocuneiform and cuneiform first metatarsal sag; lateral column lengthening was performed for calcaneovalgus deformity with a flat pitch angle; and combined procedures were performed for complex combined deformities. At 1 to 4 year followup of 65 feet, 88% of the feet that had lateral column lengthening, 80% that had medial column stabilization, and 88% of the feet that had medial and lateral procedures had a decrease in pain or were pain free. The lateral talar first metatarsal angle improved by 16 degrees in the patients in the lateral column lengthening group, 20 degrees in the patients in the medial column stabilization group, and 24 degrees in the patients in the combined medial and lateral procedures group. The anteroposterior talonavicular coverage angle improved by 14 degrees in the patients in the lateral column lengthening group, 10 degrees in the patients in the medial column stabilization group, and 14 degrees in the patients in the combined medial and lateral procedures group. These techniques effectively correct deformity without disrupting the essential joints of the hindfoot and midfoot.

  12. Why Hexagonal Basalt Columns?

    PubMed

    Hofmann, Martin; Anderssohn, Robert; Bahr, Hans-Achim; Weiß, Hans-Jürgen; Nellesen, Jens

    2015-10-09

    Basalt columns with their preferably hexagonal cross sections are a fascinating example of pattern formation by crack propagation. Junctions of three propagating crack faces rearrange such that the initial right angles between them tend to approach 120°, which enables the cracks to form a pattern of regular hexagons. To promote understanding of the path on which the ideal configuration can be reached, two periodically repeatable models are presented here involving linear elastic fracture mechanics and applying the principle of maximum energy release rate. They describe the evolution of the crack pattern as a transition from rectangular start configuration to the hexagonal pattern. This is done analytically and by means of three-dimensional finite element simulation. The latter technique reproduces the curved crack path involved in this transition.

  13. UPLC-MS/MS assay for the simultaneous quantification of carvedilol and its active metabolite 4'-hydroxyphenyl carvedilol in human plasma to support a bioequivalence study in healthy volunteers.

    PubMed

    Patel, Daxesh P; Sharma, Primal; Sanyal, Mallika; Singhal, Puran; Shrivastav, Pranav S

    2013-08-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed for the simultaneous determination of carvedilol and its pharmacologically active metabolite 4'-hydroxyphenyl carvedilol in human plasma using their deuterated internal standards (IS). Samples were prepared by solid-phase extraction using 100 μL human plasma. Chromatographic separation of analytes was achieved on UPLC C18 (50 × 2.1 mm, 1.7 µm) column using acetonitrile-4.0 mM ammonium formate, pH 3.0 adjusted with 0.1% formic acid (78:22, v/v) as the mobile phase. The multiple reaction monitoring transitions for both the analytes and IS were monitored in the positive electrospray ionization mode. The method was validated over a concentration range of 0.05-50 ng/mL for carvedilol and 0.01-10 ng/mL for 4'-hydroxyphenyl carvedilol. Intra- and inter-batch precision (% CV) and accuracy for the analytes varied from 0.74 to 3.88 and 96.4 to 103.3% respectively. Matrix effect was assessed by post-column analyte infusion and by calculation of precision values (coefficient of variation) in the measurement of the slope of calibration curves from eight plasma batches. The assay recovery was within 94-99% for both the analytes and IS. The method was successfully applied to support a bioequivalence study of 12.5 mg carvedilol tablets in 34 healthy subjects.

  14. Buckling of a holey column.

    PubMed

    Pihler-Puzović, D; Hazel, A L; Mullin, T

    2016-09-14

    We report the results from a combined experimental and numerical investigation of buckling in a novel variant of an elastic column under axial load. We find that including a regular line of centred holes in the column can prevent conventional, global, lateral buckling. Instead, the local microstructure introduced by the holes allows the column to buckle in an entirely different, internal, mode in which the holes are compressed in alternate directions, but the column maintains the lateral reflection symmetry about its centreline. The internal buckling mode can be accommodated within a smaller external space than the global one; and it is the preferred buckling mode over an intermediate range of column lengths for sufficiently large holes. For very short or sufficiently long columns a modification of the classical, global, lateral buckling is dominant.

  15. Compact electron beam focusing column

    SciTech Connect

    Persaud, Arun; Leung, Ka-Ngo; Reijonen, Jani

    2001-07-13

    A novel design for an electron beam focusing column has been developed at LBNL. The design is based on a low-energy spread multicusp plasma source which is used as a cathode for electron beam production. The focusing column is 10 mm in length. The electron beam is focused by means of electrostatic fields. The column is designed for a maximum voltage of 50 kV. Simulations of the electron trajectories have been performed by using the 2-D simulation code IGUN and EGUN. The electron temperature has also been incorporated into the simulations. The electron beam simulations, column design and fabrication will be discussed in this presentation.

  16. A high-throughput multicomponent screening method for diuretics, masking agents, central nervous system (CNS) stimulants and opiates in human urine by UPLC-MS/MS.

    PubMed

    Thörngren, John-Olof; Ostervall, Fredrik; Garle, Mats

    2008-07-01

    A simple and rapid multicomponent screening method of 130 substances for direct injections of urine samples has been developed. The fully automated method based on ultra-performance liquid chromatography (UPLC) and tandem mass spectrometry (MS/MS) is used for three different classes of doping agents: diuretics, central nervous system stimulants (CNS stimulants) and opiates. The samples are diluted with buffer containing internal standards (IS) by a pipetting robot system into 96-well plates. Samples are injected on a reversed phase sub 2-microm particle column connected to a fast polarity switching and rapid scanning tandem mass spectrometer with an electrospray interface. The software used to evaluate the results produced reports containing a small-sized window for each component and a data table list with flags to indicate any adverse analytical findings in the sample. The report can also be processed automatically using an application software, which interpret the data and indicate if there is a suspicious sample. One 96-well plate can be analyzed within 16 h.

  17. Ultrapressure liquid chromatography-tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for quantification of 4-methoxydiphenylmethane in pharmacokinetic evaluation.

    PubMed

    Farhan, Nashid; Fitzpatrick, Sean; Shim, Yun M; Paige, Mikell; Chow, Diana Shu-Lian

    2016-09-05

    4-Methoxydiphenylmethane (4-MDM), a selective augmenter of Leukotriene A4 Hydrolase (LTA4H), is a new anti-inflammatory compound for potential treatment of chronic obstructive pulmonary disease (COPD). Currently, there is no liquid chromatography tandem mass spectrometric (LC-MS/MS) method for the quantification of 4-MDM. A major barrier for developing the LC-MS/MS method is the inability of electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) to ionize 4-MDM due to its hydrophobicity and lack of any functional group for ionization. With the advent of atmospheric pressure photoionization (APPI) technique, many hydrophobic compounds have been demonstrated to ionize by charge transfer reactions. In this study, a highly sensitive ultrapressure liquid chromatography tandem mass spectrometry assay using atmospheric pressure photoionization (UPLC-APPI-MS/MS) for the quantifications of 4-MDM in rat plasma has been developed and validated. 4-MDM was extracted from the plasma by solid phase extraction (SPE) and separated chromatographically using a reverse phase C8 column. The photoionization (PI) was achieved by introducing anisole as a dopant to promote the reaction of charge transfer. The assay with a linear range of 5 (LLOQ)-400ngmL(-1) met the regulatory requirements for accuracy, precision and stability. The validated assay was employed to quantify the plasma concentrations of 4-MDM after an oral dosing in Sprague Dawley (SD) rats.

  18. Simultaneous determination of 30 hormones illegally added to anti-ageing functional foods using UPLC-MS/MS coupled with SPE clean-up.

    PubMed

    He, Xiaoqin; Xi, Cunxian; Tang, Bobin; Wang, Guomin; Chen, Dongdong; Peng, Tao; Mu, Zhaode

    2014-01-01

    A novel analytical method employing solid-phase extraction (SPE) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 30 hormones in anti-ageing functional foods (capsules, powders and tablets). The analytes were extracted with acetic acid-acetonitrile (1-99 v/v), methanol and acetone, respectively. The extract was purified using a combined column, followed by analyte detection with electrospray ionisation in positive- or negative-ion modes. The results indicated that the 30 compounds had good linear correlations in the range of 1-1000 μg kg⁻¹, and the correlation coefficients were above 0.99. The limits of detection (LOD) and limits of quantification (LOQ) were 0.03-2 and 0.1-5 μg kg⁻¹, respectively. The average recovery of 30 compounds at the three spiked levels varied from 74.7% to 124.1%, and the relative standard deviation (RSD) was 2.4-15.0%. This method was applied to the analysis of hormones in 14 real samples of which seven hormones (such as estrone, dienestrol) were detected in four samples, but the remainder of the hormones were not detected. The developed method is sensitive, efficient, reliable and applicable to real samples.

  19. Quantitative and qualitative analysis of the novel antitumor 1,3,4-oxadiazole derivative (GLB) and its metabolites using HPLC-UV and UPLC-QTOF-MS.

    PubMed

    Li, Pu; Wang, Xin; Li, Jian; Meng, Zhi-Yun; Li, Shu-Chun; Li, Zhong-Jun; Lu, Ying-Yuan; Ren, Hong; Lou, Ya-Qing; Lu, Chuang; Dou, Gui-Fang; Zhang, Guo-Liang

    2015-07-07

    Fructose-based 3-acetyl-2,3-dihydro-1,3,4-oxadiazole (GLB) is a novel antitumor agent and belongs to glycosylated spiro-heterocyclic oxadiazole scaffold derivative. This research first reported a simple, specific, sensitive and stable high performance liquid chromatography-ultraviolet detector (HPLC-UV) method for the quantitative determination of GLB in plasma. In this method, the chromatographic separation was achieved with a reversed phase C18 column. The calibration curve for GLB was linear at 300 nm. The lower limit of quantification was 10 ng/mL. The precision, accuracy and stability of the method were validated adequately. This method was successfully applied to the pharmacokinetic study in rats for detection of GLB after oral administration. Moreover, the structures of parent compound GLB and its two major metabolites M1 and M2 were identified in plasma using an ultra performance liquid chromatography-electrospray ionization-quadrupole-time of flight- mass spectrometry (UPLC-ESI-QTOF-MS) method. Our results indicated that the di-hydroxylation (M1) and hydroxylation (M2) of GLB are the major metabolites. In conclusion, the present study provided valuable information on an analytical method for the determination of GLB and its metabolites in rats, can be used to support further developing of this antitumor agent.

  20. Stability-indicating UPLC method for determination of Valsartan and their degradation products in active pharmaceutical ingredient and pharmaceutical dosage forms.

    PubMed

    Krishnaiah, Ch; Reddy, A Raghupathi; Kumar, Ramesh; Mukkanti, K

    2010-11-02

    A simple, precise, accurate stability-indicating gradient reverse phase ultra-performance liquid chromatographic (RP-UPLC) method was developed for the quantitative determination of purity of Valsartan drug substance and drug products in bulk samples and pharmaceutical dosage forms in the presence of its impurities and degradation products. The method was developed using Waters Aquity BEH C18 (100 mm x 2.1 mm, 1.7 microm) column with mobile phase containing a gradient mixture of solvents A and B. The eluted compounds were monitored at 225 nm, the run time was within 9.5 min, which Valsartan and its seven impurities were well separated. Valsartan was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Valsartan was found to degrade significantly in acid and oxidative stress conditions and stable in base, hydrolytic and photolytic degradation conditions. The degradation products were well resolved from main peak and its impurities, proving the stability-indicating power of the method. The developed method was validated as per international conference on harmonization (ICH) guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of Valsartan in pharmaceutical dosage forms.

  1. Rapid separation of seed gliadins by reversed-phase ultra performance liquid chromatography (RP-UPLC) and its application in wheat cultivar and germplasm identification.

    PubMed

    Han, Caixia; Lu, Xaiobing; Yu, Zitong; Li, Xiaohui; Ma, Wujun; Yan, Yueming

    2015-01-01

    To separate gliadin from wheat flour, a novel and stability-indicating reversed-phase ultra performance liquid chromatography (RP-UPLC) method is established and optimized. A comparative analysis of routine capillary electrophoresis (CE), reversed-phase high-performance liquid chromatography (RP-HPLC), and RP-UPLC was performed and the results showed that the resolution and efficiency of RP-UPLC were significantly higher than those of CE and RP-HPLC. Characteristic RP-UPLC patterns of different bread wheat variety and related species were readily identified. These results demonstrated that our RP-UPLC procedure resulted in significant improvements in sensitivity, speed, and resolution, and thus is highly useful in wheat cultivar and germplasm identification.

  2. Comprehensive screening and quantification of veterinary drugs in milk using UPLC-ToF-MS.

    PubMed

    Stolker, A A M; Rutgers, P; Oosterink, E; Lasaroms, J J P; Peters, R J B; van Rhijn, J A; Nielen, M W F

    2008-07-01

    Ultra-performance liquid chromatography combined with time-of-flight mass spectrometry (UPLC-ToF-MS) has been used for screening and quantification of more than 100 veterinary drugs in milk. The veterinary drugs represent different classes including benzimidazoles, macrolides, penicillins, quinolones, sulphonamides, pyrimidines, tetracylines, nitroimidazoles, tranquillizers, ionophores, amphenicols and non-steroidal anti-inflammatory agents (NSAIDs). After protein precipitation, centrifugation and solid-phase extraction (SPE), the extracts were analysed by UPLC-ToF-MS. From the acquired full scan data the drug-specific ions were extracted for construction of the chromatograms and evaluation of the results. The analytical method was validated according to the EU guidelines (2002/657/EC) for a quantitative screening method. At the concentration level of interest (MRL level) the results for repeatability (%RSD < 20% for 86% of the compounds), reproducibility (%RSD < 40% for 96% of the compounds) and the accuracy (80-120% for 88% of the compounds) were satisfactory. Evaluation of the CCbeta values and the linearity results demonstrates that the developed method shows adequate sensitivity and linearity to provide quantitative results. Furthermore, the method is accurate enough to differentiate between suspected and negative samples or drug concentrations below or above the MRL. A set of 100 samples of raw milk were screened for residues. No suspected (positive) results were obtained except for the included blind reference sample containing sulphamethazine (88 microg/l) that tested positive for this compound. UPLC-ToF-MS combines high resolution for both LC and MS with high mass accuracy which is very powerful for the multi-compound analysis of veterinary drugs. The technique seems to be powerful enough for the analysis of not only veterinary drugs but also organic contaminants like pesticides, mycotoxins and plant toxins in one single method.

  3. Dorsal column stimulator applications

    PubMed Central

    Yampolsky, Claudio; Hem, Santiago; Bendersky, Damián

    2012-01-01

    Background: Spinal cord stimulation (SCS) has been used to treat neuropathic pain since 1967. Following that, technological progress, among other advances, helped SCS become an effective tool to reduce pain. Methods: This article is a non-systematic review of the mechanism of action, indications, results, programming parameters, complications, and cost-effectiveness of SCS. Results: In spite of the existence of several studies that try to prove the mechanism of action of SCS, it still remains unknown. The mechanism of action of SCS would be based on the antidromic activation of the dorsal column fibers, which activate the inhibitory interneurons within the dorsal horn. At present, the indications of SCS are being revised constantly, while new applications are being proposed and researched worldwide. Failed back surgery syndrome (FBSS) is the most common indication for SCS, whereas, the complex regional pain syndrome (CRPS) is the second one. Also, this technique is useful in patients with refractory angina and critical limb ischemia, in whom surgical or endovascular treatment cannot be performed. Further indications may be phantom limb pain, chronic intractable pain located in the head, face, neck, or upper extremities, spinal lumbar stenosis in patients who are not surgical candidates, and others. Conclusion: Spinal cord stimulation is a useful tool for neuromodulation, if an accurate patient selection is carried out prior, which should include a trial period. Undoubtedly, this proper selection and a better knowledge of its underlying mechanisms of action, will allow this cutting edge technique to be more acceptable among pain physicians. PMID:23230533

  4. Quantitative determination of alkaloids from roots of Hydrastis canadensis L. and dietary supplements using ultra-performance liquid chromatography with UV detection.

    PubMed

    Avula, Bharathi; Wang, Yan-Hong; Khan, Ikhlas A

    2012-01-01

    Ultra-performance liquid chromatography (UPLC) with UV detection was used for the quantification of alkaloids from roots of Hydrastis canadensis L. (goldenseal) and dietary supplements claiming to contain goldenseal. The analysis was performed on a Waters Acquity UPLC system with an Acquity UPLC BEH Shield RP18 column using gradient elution with ammonium formate and acetonitrile containing formic acid. The chromatographic run time was less than 6 min. The detection wavelength used for beta-hydrastine and canadine was 290 nm; for hydrastinine, coptisine, jatrorrhizine, palmatine, and berberine, it was 344 nm. A total of five different extraction solvents, including 100% methanol, 90% methanol, 90% methanol + 1% acetic acid, 90% acetonitrile + 0.1% phosphoric acid, and 100% acetonitrile, were tested for recovery of the major compounds. The samples extracted with the 90% methanol + 1% acetic acid displayed the best recovery (>97%). The analytical method was validated for linearity, repeatability, LOD, and LOQ. The RSDs for intraday and interday experiments were less than 3.5%, and the recovery was 98-103%. UPLC/MS with a quadrupole mass analyzer and electrospray ionization source was used to confirm the identity of seven alkaloids. The analytical method was successfully applied to confirm the identification of seven alkaloids from the roots of H. canadensis, dietary supplements that claimed to contain goldenseal, and possible adulterant species.

  5. Concurrent determination of olanzapine, risperidone and 9-hydroxyrisperidone in human plasma by ultra performance liquid chromatography with diode array detection method: application to pharmacokinetic study.

    PubMed

    Siva Selva Kumar, M; Ramanathan, M

    2016-02-01

    A simple and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9-hydroxyrisperidone (9-OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9-OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1-100 ng/mL for OLZ, RIS and 9-OHRIS. Intra- and inter-day precisions for OLZ, RIS and 9-OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9-OHRIS in human plasma.

  6. Automatic connector joins structural columns

    NASA Technical Reports Server (NTRS)

    Jacquemin, G. G.

    1980-01-01

    Connector snap-locks over toothed bolthead mounted on column end, forming rigid joint that will not bend or twist. Connector is used in conventional construction to install temporary structures or as mechanical coupler. Up to nine receptacles can be clustered in one node to join up to nine converging columns.

  7. An Undergraduate Column Chromatography Experiment.

    ERIC Educational Resources Information Center

    Danot, M.; And Others

    1984-01-01

    Background information, list of materials needed, and procedures used are provided for an experiment designed to introduce undergraduate students to the theoretical and technical aspects of column chromatography. The experiment can also be shortened to serve as a demonstration of the column chromatography technique. (JN)

  8. A UPLC-MSMS method for the analysis of olanzapine in serum-with particular emphasis on drug stability testing.

    PubMed

    Andreassen, Trine Naalsund; Falch, Berit Margrethe Hasle; Spigset, Olav

    2015-12-01

    A method including a rapid and automated extraction of olanzapine from serum followed by ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) has been developed and validated. Serum aliquots (100μL) and internal standard (olanzapine-d3, 25μL) were pipetted onto an Ostro(TM) 96-well filtration plate and protein precipitated with acidic acetonitrile (300μL) before removal of endogenous phospholipids by filtration followed by analysis. Chromatography was achieved using an HSST 3 (2.1×100mm, 1.8μm) column and gradient elution with acidic water in combination with methanol at a flow rate of 0.5mL/min. The runtime was 1.5min. The mass spectrometer was monitored in positive mode and multiple reaction monitoring (MRM). The m/z 313.1>256.1 and 313.1>198.0 transitions were monitored for olanzapine (m/z 316.1>256.1 for olanzapine-d3). The quadratic calibration curves ranged from 5 to 500nM (R(2)≥0.999). Limit of quantification was 0.5nM (CV 9.6%, accuracy 110%). Within-assay and between-assay inaccuracies were 2.6-11.9% (CV≤4.8%). Recovery was 84-95% (CV≤1.4%) and matrix effects ranged from 100 to 103% (CV≤2.6%). Extensive stability testing showed that at ambient temperature, olanzapine in patient serum samples were stable for at least seven hours on the laboratory bench and for at least 48h in darkness. When exposed to 3000lux, however, significant degradation had occurred after 48h. Notably, olanzapine in spiked serum was unstable already after four hours when exposed to 3000 lux. At 4-8°C and exposure to 550lux, both patient serum and spiked serum were stable for more than 48h but less than a week, whereas in darkness, the samples were stable for at least 14 days. The cumulative light exposure causing significant degradation of olanzapine in patient serum was 50,000-100,000lux-h. In some individual samples, however, the effect of light exposure was more pronounced. Therefore, it seems pertinent to recommend protecting all samples from

  9. Simultaneous determination of erlotinib and tamoxifen in rat plasma using UPLC-MS/MS: Application to pharmacokinetic interaction studies.

    PubMed

    Maher, Hadir M; Alzoman, Nourah Z; Shehata, Shereen M

    2016-08-15

    Tamoxifen (TAM) is a non-steroidal estrogen receptor antagonist that enhances erlotinib (ERL)-induced cytotoxicity in the treatment of NSCLC. ERL and TAM are metabolized by CYP3A4 enzymes. In addition, both drugs have the potential of altering the enzymatic activity through either inhibition (ERL) or induction (TAM). Thus it was expected that pharmacokinetics (PK) drug-drug interactions (DDIs) could be encountered following their co-administration. In this respect, a bioanalytical UPLC-MS/MS method has been developed and validated for the simultaneous determination of ERL and TAM in rat plasma samples, using ondansetron (OND) as an internal standard (IS). Plasma samples were prepared using mixed mode cationic solid phase extraction (SPE) STRATA™ -X-C 33μm cartridges with good extraction recovery of both drugs from rat plasma (Er% from -13.92 to -3.32). The drugs were separated on a Waters BEH™ C18 column with an isocratic elution using a mobile phase composed of a mixture of acetonitrile and water, each with 0.15% formic acid, in the ratio of 80: 20, v/v. Quantitation was carried out using the positive ionization mode with multiple reaction monitoring (MRM) at m/z 394.20>278.04 (ERL), m/z 372.25>72.01 (TAM), and m/z 294.18>170.16 (OND). The method was fully validated as per the FDA guidelines over the concentration range of 0.2-50ng/mL with very low lower limit of quantification (LLOQ) of 0.2ng/mL for both ERL and TAM. The intra- and inter-day assay precision (in terms of relative standard deviation, RSD) and accuracy (in terms of percentage relative error, % Er) were evaluated for both drugs and the calculated values evaluated at four different concentration levels were within the acceptable limits (<15%) for concentrations other than LLOQ and 20% for LLOQ. The method was successfully applied to the study of possible PK-DDI following the oral administration of ERL and TAM in a combination, compared to their single administration.

  10. Comparison of column flotation cells

    SciTech Connect

    Honaker, R.Q.; Mohanty, M.K.; Ho, K.

    1995-08-01

    Six commercial column flotation technologies, i.e., Canadian, Flotaire, Jameson, Microcel, Packed-Column, and Turbo-air, were tested for the treatment of Illinois Basin fine coal and the results from each column compared based on separation performance and throughout capacity. The separation performance achieved by each cell approached and, in some cases, exceeded the ultimate performance predicted by release analysis. A comparison of the test results indicates differences in the selectivity obtained by each flotation column on the basis of both ash and sulfur rejection. This finding may be due to variations in cell hydrodynamics and the ability to support a deep froth phase among the different column cells. In addition, throughput capacity of each cell was found to differ, apparently due to the differences in the bubble-particle attachment environment, bubble size, and bubble population. Variations in the operating characteristics, such as reagent additions, aeration rate and wash water rate, were also noted and summarized in this publication.

  11. Mush Column Magma Chambers

    NASA Astrophysics Data System (ADS)

    Marsh, B. D.

    2002-12-01

    Magma chambers are a necessary concept in understanding the chemical and physical evolution of magma. The concept may well be similar to a transfer function in circuit or time series analysis. It does what needs to be done to transform source magma into eruptible magma. In gravity and geodetic interpretations the causative body is (usually of necessity) geometrically simple and of limited vertical extent; it is clearly difficult to `see' through the uppermost manifestation of the concentrated magma. The presence of plutons in the upper crust has reinforced the view that magma chambers are large pots of magma, but as in the physical representation of a transfer function, actual magma chambers are clearly distinct from virtual magma chambers. Two key features to understanding magmatic systems are that they are vertically integrated over large distances (e.g., 30-100 km), and that all local magmatic processes are controlled by solidification fronts. Heat transfer considerations show that any viable volcanic system must be supported by a vertically extensive plumbing system. Field and geophysical studies point to a common theme of an interconnected stack of sill-like structures extending to great depth. This is a magmatic Mush Column. The large-scale (10s of km) structure resembles the vertical structure inferred at large volcanic centers like Hawaii (e.g., Ryan et al.), and the fine scale (10s to 100s of m) structure is exemplified by ophiolites and deeply eroded sill complexes like the Ferrar dolerites of the McMurdo Dry Valleys, Antarctica. The local length scales of the sill reservoirs and interconnecting conduits produce a rich spectrum of crystallization environments with distinct solidification time scales. Extensive horizontal and vertical mushy walls provide conditions conducive to specific processes of differentiation from solidification front instability to sidewall porous flow and wall rock slumping. The size, strength, and time series of eruptive behavior

  12. Comparative UPLC-QTOF-MS-based metabolomics and bioactivities analyses of Garcinia oblongifolia.

    PubMed

    Li, Ping; AnandhiSenthilkumar, Harini; Wu, Shi-biao; Liu, Bo; Guo, Zhi-yong; Fata, Jimmie E; Kennelly, Edward J; Long, Chun-lin

    2016-02-01

    Garcinia oblongifolia Champ. ex Benth. (Clusiaceae) is a well-known medicinal plant from southern China, with edible fruits. However, the phytochemistry and bioactivity of the different plant parts of G. oblongifolia have not been studied extensively. Comparative metabolic profiling and bioactivities of the leaf, branch, and fruit of G. oblongifolia were investigated. A total of 40 compounds such as biflavonoids, xanthones, and benzophenones were identified using UPLC-QTOF-MS and MS(E), including 15 compounds reported for the first time from this species. Heatmap analyses found that benzophenones, xanthones, and biflavonoids were predominately found in branches, with benzophenones present in relatively high concentrations in all three plant parts. Xanthones were found to have limited distribution in fruit while biflavonoids were present at only low levels in leaves. In addition, the cytotoxic (MCF-7 breast cancer cell line) and antioxidant (ABTS and DPPH chemical tests) activities of the crude extracts of G. oblongifolia indicate that the branch extract exhibits greater bioactivity than either the leaf or the fruit extracts. Orthogonal partial least squares discriminate analysis was used to find 12 marker compounds, mainly xanthones, from the branches, including well-known antioxidants and cytotoxic agents. These G. oblongifolia results revealed that the variation in metabolite profiles can be correlated to the differences in bioactivity of the three plant parts investigated. This UPLC-QTOF-MS strategy can be useful to identify bioactive constituents expressed differentially in the various plant parts of a single species.

  13. Identification and quantitation of new glutamic acid derivatives in soy sauce by UPLC/MS/MS.

    PubMed

    Frerot, Eric; Chen, Ting

    2013-10-01

    Glutamic acid is an abundant amino acid that lends a characteristic umami taste to foods. In fermented foods, glutamic acid can be found as a free amino acid formed by proteolysis or as a non-proteolytic derivative formed by microorganisms. The aim of the present study was to identify different structures of glutamic acid derivatives in a typical fermented protein-based food product, soy sauce. An acidic fraction was prepared with anion-exchange solid-phase extraction (SPE) and analyzed by UPLC/MS/MS and UPLC/TOF-MS. α-Glutamyl, γ-glutamyl, and pyroglutamyl dipeptides, as well as lactoyl amino acids, were identified in the acidic fraction of soy sauce. They were chemically synthesized for confirmation of their occurrence and quantified in the selected reaction monitoring (SRM) mode. Pyroglutamyl dipeptides accounted for 770 mg/kg of soy sauce, followed by lactoyl amino acids (135 mg/kg) and γ-glutamyl dipeptides (70 mg/kg). In addition, N-succinoylglutamic acid was identified for the first time in food as a minor compound in soy sauce (5 mg/kg).

  14. Determination of buprenorphine, fentanyl and LSD in whole blood by UPLC-MS-MS.

    PubMed

    Berg, Thomas; Jørgenrud, Benedicte; Strand, Dag Helge

    2013-04-01

    A sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method has been developed and validated for the quantification of buprenorphine, fentanyl and lysergic acid diethylamide (LSD) in whole blood. Sample preparation was performed by liquid-liquid extraction (LLE) with methyl tert-butyl ether. UPLC-MS-MS analysis was performed with a mobile phase consisting of ammonium formate (pH 10.2) and methanol. Positive electrospray ionization MS-MS detection was performed with two multiple reaction monitoring transitions for each of the analytes and the deuterium labeled internal standards. Limit of detection values of buprenorphine, fentanyl and LSD were 0.28, 0.044 and 0.0097 ng/mL and limit of quantification values were 0.94, 0.14 and 0.036 ng/mL, respectively. Most phospholipids were removed during LLE. No or only minor matrix effects were observed. The method has been routinely used at the Norwegian Institute of Public Health since September 2011 for qualitative and quantitative detections of buprenorphine, fentanyl and/or LSD in more than 400 whole blood samples with two replicates per sample.

  15. Multimycotoxin UPLC-MS/MS for tea, herbal infusions and the derived drinkable products.

    PubMed

    Monbaliu, Sofie; Wu, Aibo; Zhang, Dabing; Van Peteghem, Carlos; De Saeger, Sarah

    2010-12-22

    In recent years the consumption of tea and herbal infusions has increased. These hot drinks are consumed as daily drinks as well as for medicinal purposes. All tea varieties (white, yellow, green, oolong, black and puerh) originate from the leaves of the tea plant, Camellia sinensis. All extracts made of plant or herbal materials which do not contain Camellia sinensis are referred as herbal infusions or tisanes. During processing and manufacturing fungal contamination of the plant materials is possible, enabling contamination of these products with mycotoxins. In this study a multimycotoxin UPLC-MS/MS method was developed and validated for the analysis of the raw tea and herbal infusion materials as well as for their drinkable products. The samples were analyzed by ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), with a mobile phase consisting of variable mixtures of water and methanol with 0.3% formic acid. The limits of detection for the different mycotoxins varied between 2.1 μg/kg and 121 μg/kg for raw materials and between 0.4 μg/L and 46 μg/L for drinkable products. Afterward 91 different tea and herbal infusion samples were analyzed. Only in one sample, Ceylon melange, 76 μg/kg fumonisin B(1) was detected. No mycotoxins were detected in the drinkable products.

  16. Novel strategy for herbal species classification based on UPLC-HRMS oligosaccharide profiling.

    PubMed

    Tie, Cai; Hu, Ting; Guo, Baolin; Zhang, Jinlan

    2015-01-01

    Oligosaccharides, which exist widely in herbs, present diverse important pharmacological activities. However, the complexity of oligosaccharides seriously challenges their profiling, quality control, and elucidation of activity. In this paper, a novel oligosaccharide analytical method based on a new derivatization pretreatment and ultra-performance liquid chromatography coupled with high resolution tandem mass spectrometry (UPLC-HRMS) procedure was developed to rapidly profile and identify the oligosaccharides of Epimedium. Oligosaccharides are easily derivatized by 2,4-bis(diethylamino)-6-hydrazino-1,3,5-triazine under convenient and mild conditions. Without any further purification steps, oligosaccharides were analyzed by an established UPLC-HRMS/MS method with high sensitivity, good separation efficiency and speed. Benefitting from the derivatization, the oligosaccharides generated a response in the MS two orders of magnitude higher than that of the free oligosaccharide. Oligosaccharides of 52 Epimedium samples were profiled and identified based on the high-resolution mass spectral data. A total of 66 oligosaccharide compounds detected in 52 Epimedium herbs were relatively quantified and statistically processed by principal component analysis (PCA). The 52 Epimedium herbs could be classified into different species based on their oligosaccharide composition and content. Thirteen oligosaccharide compounds demonstrated potential as markers for Epimedium species classification, and their structures were preliminarily identified using MS/MS spectra.

  17. Comparative study of three Plumbago L. species (Plumbaginaceae) by microscopy, UPLC-UV and HPTLC.

    PubMed

    Galal, Ahmed M; Raman, Vijayasankar; Avula, Bharathi; Wang, Yan-Hong; Rumalla, Chidananda Swamy; Weerasooriya, Aruna Dharmapriya; Khan, Ikhlas A

    2013-07-01

    This paper presents a comparative study of anatomy of leaves, stems and roots of three species of Plumbago, namely P. auriculata Lam., P. indica L. and P. zeylanica L. by light microscopy. The paper also provides qualitative and quantitative analysis of the naphthoquinone, plumbagin-a major constituent present in these species-using UPLC-UV. Microscopic examinations revealed the presence of distinctive differences in the anatomical features of the leaf, stem and root of the three species, and these can thus be used for identification and authentication of these species. UPLC-UV analysis showed the highest concentration of plumbagin in the roots of P. zeylanica (1.62% w/w) followed by the roots of P. indica (0.97% w/w) and then P. auriculata (0.33-0.53% w/w). In contrast, plumbagin was not detected in the stems and leaves of P. indica and in the leaves of P. auriculata, whereas very low concentrations (<0.02% w/w) of plumbagin were detected in the stems and leaves of P. zeylanica and in the stems of P. auriculata. HPTLC fingerprints of the leaf and root of the three species exhibited distinguishable profiles, while those of the stems were undifferentiated.

  18. Quantification of sialic acids in red meat by UPLC-FLD using indoxylsialosides as internal standards.

    PubMed

    Yao, Hong L; Conway, Louis P; Wang, Mao M; Huang, Kun; Liu, Li; Voglmeir, Josef

    2016-04-01

    Herein we describe a UPLC-FLD-based method for the quantification of the sialic acid content of red meat, using a synthetic neuraminic acid derivative as an internal standard. X-Gal-α-2,6-N-propionylneuraminic acid was synthesized via a chemoenzymatic pathway and its hydrolytic stability was characterized. Known quantities of this compound were incubated with samples of red meat under sialic acid-releasing conditions. The released sialic acids were derivatized, analyzed by UPLC-FLD, and the Neu5Ac/Neu5Gc content of the meat sample was determined by comparison with the internal standard. A number of red meats were analyzed by this method with the following results (Neu5Ac μg/g tissue, Neu5Gc μg/g tissue ± s.d.): pork (68 ± 3, 15.2 ± 0.7), beef (69 ± 8, 36 ± 5), lamb (46 ± 2, 33 ± 1), rabbit (59 ± 2, 0.4 ± 0.4), and hare (50 ± 4, 1 ± 1). We envisage that this methodology will find application in investigating the health effects of dietary Neu5Gc. Graphical abstract ᅟ.

  19. Comparative Metabolism of Cyclophosphamide and Ifosfamide in the Mouse Using UPLC-ESI-QTOFMS-Based Metabolomics

    PubMed Central

    Li, Fei; Patterson, Andrew D.; Höfer, Constance C.; Krausz, Kristopher W.; Gonzalez, Frank J.; Idle, Jeffrey R.

    2010-01-01

    Ifosfamide (IF) and cyclophosphamide (CP) are common chemotherapeutic agents. Interestingly, while the two drugs are isomers, only IF treatment is known to cause nephrotoxicity and neurotoxicity. Therefore, it was anticipated that a comparison of IF and CP drug metabolites in the mouse would reveal reasons for this selective toxicity. Drug metabolites were profiled by ultra-performance liquid chromatography-linked electrospray ionization quadrupole time-of-flight mass spectrometry (UPLC-ESI-QTOFMS), and the results analyzed by multivariate data analysis. Of the total 23 drug metabolites identified by UPLC-ESI-QTOFMS for both IF and CP, five were found to be novel. Ifosfamide preferentially underwent N-dechloroethylation, the pathway yielding 2-chloroacetaldehyde, while cyclophosphamide preferentially underwent ring-opening, the pathway yielding acrolein (AC). Additionally, S-carboxymethylcysteine and thiodiglycolic acid, two downstream IF and CP metabolites, were produced similarly in both IF- and CP-treated mice. This may suggest that other metabolites, perhaps precursors of thiodiglycolic acid, may be responsible for IF encephalopathy and nephropathy. PMID:20541539

  20. Seismic behavior of lightweight concrete columns

    NASA Astrophysics Data System (ADS)

    Rabbat, B. G.; Daniel, J. I.; Weinmann, T. L.; Hanson, N. W.

    1982-09-01

    Sixteen full-scale, column-beam assemblies, which represented a portion of a frame subjected to simulated seismic loading, were tested. Controlled test parameters included concrete type, column size, amount of main column steel, size and spacing of column confining hoops, and magnitude of column axial load. The columns were subjected to constant axial load and slow moment reversals at increasing inelastic deformations. Test data showed that properly designed lightweight concrete columns maintained ductility and strength when subjected to large inelastic deformations from load reversals. Confinement requirements for normal weight concrete columns were shown to be applicable to lightweight concrete columns up to thirty percent of the design strength.

  1. Quantitative determination of alkaloids from roots of Hydrastis canadensis L. and dietary supplements using UPLC-UV-MS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    UPLC with UV detection was used for the quantification of alkaloids from roots of Hydrastis canadensis L. (goldenseal) and dietary supplements claiming to contain goldenseal. The chromatographic run time was less than 6 min. The detection wavelengths used were 290 and 344 nm for '-hydrastine, canadi...

  2. Determination of sotolon content in South African white wines by two novel HPLC-UV and UPLC-MS methods.

    PubMed

    Gabrielli, Mario; Buica, Astrid; Fracassetti, Daniela; Stander, Marietjie; Tirelli, Antonio; du Toit, Wessel J

    2015-02-15

    Sotolon has been reported to play an important role in the atypical ageing and aroma character of many wines. A number of analytical techniques for sotolon analysis in wine have been reported, but these often require extensive sample preparation. In this work we report a HPLC-UV method and a novel UPLC-MS method to determine sotolon concentrations in white wines with little sample preparation applied for the first time for the evaluation of sotolon levels in South African wines. The validation showed that the instrumental methods had good accuracy, repeatability and linearity, but the UPLC-MS method proved more sensitive. For both methods, quantification limits were lower than the sotolon odour threshold in wine (10μg/L), 0.86μg/L and 0.013μg/L, for HPLC-UV and UPLC-MS methods, respectively. Sotolon levels in 65 South African white wines were often found to be lower than the reported odour threshold, with the highest concentration being 9.11μg/L. However, for low levels (<1μg/L), unknown interferences in certain wines led to sotolon not being quantified with the HPLC-UV method, which made the UPLC-MS method more suitable.

  3. DETERMINATION OF ECOLOGICALLY RELEVANT PHARMACEUTICALS AND THEIR SELECTED METABOLITES IN EFFLUENT AND SURFACE WATER USING UPLC/MS/MS

    EPA Science Inventory

    Objective is to develop analytical methods including SPE and UPLC/MS/MS needed to analyze over 60 human prescription pharamceuticals and metabolites belonging to a multitude of different classes in surface waters and wastewater effluent. The methods will be used in future studies...

  4. Analytical methods for determination of alkaloids and saponins from roots of Caulophyllum thalictroids (L) Michx using UPLC HPLC and HPTLC

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A comparison study of analytical methods including HPLC, UPLC and HPTLC are presented in this paper for the determination of major alkaloid and triterpene saponins from the roots of Caulophyllum thalictroides (L.) Michx. (blue cohosh) and dietary supplements claiming to contain blue cohosh. The meth...

  5. Self-regenerating column chromatography

    DOEpatents

    Park, W.K.

    1995-05-30

    The present invention provides a process for treating both cations and anions by using a self-regenerating, multi-ionic exchange resin column system which requires no separate regeneration steps. The process involves alternating ion-exchange chromatography for cations and anions in a multi-ionic exchange column packed with a mixture of cation and anion exchange resins. The multi-ionic mixed-charge resin column works as a multi-function column, capable of independently processing either cationic or anionic exchange, or simultaneously processing both cationic and anionic exchanges. The major advantage offered by the alternating multi-function ion exchange process is the self-regeneration of the resins.

  6. Telescoping columns. [parabolic antenna support

    NASA Technical Reports Server (NTRS)

    Mazur, J. T. (Inventor)

    1980-01-01

    An extendable column is described which consists of several axially elongated rigid structural sections nested within one another. Each section includes a number of rotatably attached screws running along its length. The next inner section includes threaded lugs oriented to threadingly engage the screws. The column is extended or retracted upon rotation of the screws. The screws of each section are selectively rotated by a motor and an engagement mechanism.

  7. LIQUID-LIQUID EXTRACTION COLUMNS

    DOEpatents

    Thornton, J.D.

    1957-12-31

    This patent relates to liquid-liquid extraction columns having a means for pulsing the liquid in the column to give it an oscillatory up and down movement, and consists of a packed column, an inlet pipe for the dispersed liquid phase and an outlet pipe for the continuous liquid phase located in the direct communication with the liquid in the lower part of said column, an inlet pipe for the continuous liquid phase and an outlet pipe for the dispersed liquid phase located in direct communication with the liquid in the upper part of said column, a tube having one end communicating with liquid in the lower part of said column and having its upper end located above the level of said outlet pipe for the dispersed phase, and a piston and cylinder connected to the upper end of said tube for applying a pulsating pneumatic pressure to the surface of the liquid in said tube so that said surface rises and falls in said tube.

  8. Identification and Quantitation of Anthocyanins in Purple-Fleshed Sweet Potatoes Cultivated in China by UPLC-PDA and UPLC-QTOF-MS/MS.

    PubMed

    He, Wei; Zeng, Maomao; Chen, Jie; Jiao, Yuzhi; Niu, Fuxiang; Tao, Guanjun; Zhang, Shuang; Qin, Fang; He, Zhiyong

    2016-01-13

    The identification and quantitation of the anthocyanins in 12 purple-fleshed sweet potato (PFSP) cultivars ('Jihei 1', 'Xuzi 3', 'Xuzi 6', 'Zhezi 4', 'Ningzi 1', 'Ningzi 2', 'Ningzi 3', 'Ning 2-2', 'Ning 6-8', 'Guangzi 1', 'Ziluolan', and 'Qinzi 1') in China were carried out using a combination of ultraperformance liquid chromatography-photodiode array (UPLC-PDA), quadrupole-time-of-flight mass spectrometry (QTOF-MS), and tandem mass spectrometry (MS/MS) analyses. Thirteen acylated anthocyanins were tentatively characterized, including two new PFSP anthocyanins, cyanidin 3-caffeoyl-vanilloyl sophoroside-5-glucoside and peonidin 3-caffeoyl-vanilloyl sophoroside-5-glucoside. The quantitative analyses of these anthocyanins were conducted using cyanidin 3-O-glucoside as a standard. The total anthocyanin content of the PFSPs depended on the cultivar. The five PFSP cultivars with the highest content of anthocyanins were 'Jihei 1', 'Xuzi 3', 'Zhezi 4', 'Ziluolan', and 'Qinzi 1'. This is the first report of the 'Ningzi 2', 'Ningzi 3', and 'Ning 2-2' PFSP cultivars containing only diacylated anthocyanins and of the 'Xuzi 6' cultivar containing single anthocyanidin-based anthocyanins.

  9. Rapid screening of mycotoxins in liquid milk and milk powder by automated size-exclusion SPE-UPLC-MS/MS and quantification of matrix effects over the whole chromatographic run.

    PubMed

    Wang, Xiupin; Li, Peiwu

    2015-04-15

    An automated, size-exclusion solid phase extraction (SPE)-UPLC-MS/MS protocol without pre-treatment of samples was developed to screen for four mycotoxins (OTA, ZEN, AFB1, and AFM1) in liquid milk and milk powder. Firstly, a mixed macropore-silica gel cartridge was established as a size-exclusion SPE column. The proposed methodology could be a candidate in green analytical chemistry because it saves on manpower and organic solvent. Permanent post-column infusion of mycotoxin standards was used to quantify matrix effects throughout the chromatographic run. Matrix-matched calibration could effectively compensate for matrix effects, which may be caused by liquid milk or milk powder matrix. Recovery of the four mycotoxins in fortified liquid milk was in the range 89-120% and RSD 2-9%. The LOD for the four mycotoxins in liquid milk and milk powder were 0.05-2 ng L(-1) and 0.25-10 ng kg(-1), respectively. The LOQ for the four mycotoxins in liquid milk and milk powder were 0.1-5 ng L(-1) and 0.5-25 ng kg(-1), respectively.

  10. Novel identification strategy for ground coffee adulteration based on UPLC-HRMS oligosaccharide profiling.

    PubMed

    Cai, Tie; Ting, Hu; Jin-Lan, Zhang

    2016-01-01

    Coffee is one of the most common and most valuable beverages. According to International Coffee Organization (ICO) reports, the adulteration of coffee for financial reasons is regarded as the most serious threat to the sustainable development of the coffee market. In this work, a novel strategy for adulteration identification in ground coffee was developed based on UPLC-HRMS oligosaccharide profiling. Along with integrated statistical analysis, 17 oligosaccharide composition were identified as markers for the identification of soybeans and rice in ground coffee. This strategy, validated by manual mixtures, optimized both the reliability and authority of adulteration identification. Rice and soybean adulterants present in ground coffee in amounts as low as 5% were identified and evaluated. Some commercial ground coffees were also successfully tested using this strategy.

  11. Free amino acid profiling in the giant puffball mushroom (Calvatia gigantea) using UPLC-MS/MS.

    PubMed

    Kıvrak, İbrahim; Kıvrak, Şeyda; Harmandar, Mansur

    2014-09-01

    Wild edible and medicinal mushroom, Calvatia gigantea, was quantitatively analyzed for the determination of its free amino acids using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The concentrations of total free amino acids, essential and non-essential amino acids were 199.65 mg/100 g, 113.69 mg/100 g, and 85.96 mg/100 g in C. gigantea, respectively. This study showed that C. gigantea, so called a giant puffball mushroom, has free amino acids content. The essential amino acids: tryptophan, isoleucine, valine, phenylalanine, leucine, threonine, lysine, histidine, methionine, and the non-essential amino acids: tyrosine, 4-hyrdroxy proline, arginine, proline, glycine, serine, alanine, glutamine, glutamic acid, aspargine, aspartic acid were detected.

  12. Rapid and reproducible determination of active gibberellins in citrus tissues by UPLC/ESI-MS/MS.

    PubMed

    Manzi, Matías; Gómez-Cadenas, Aurelio; Arbona, Vicent

    2015-09-01

    Phytohormone determination is crucial to explain the physiological mechanisms during growth and development. Therefore, rapid and precise methods are needed to achieve reproducible determination of phytohormones. Among many others, gibberellins (GAs) constitute a family of complex analytes as most of them share similar structure and chemical properties although only a few hold biological activity (namely GA1; GA3; GA4 and GA7). A method has been developed to extract GAs from plant tissues by mechanical disruption using ultrapure water as solvent and, in this way, ion suppression was reduced whereas sensitivity increased. Using this methodology, the four active GAs were separated and quantified by UPLC coupled to MS/MS using the isotope-labeled internal standards [(2)H2]-GA1 and [(2)H2]-GA4. To sum up, the new method provides a fast and reproducible protocol to determine bioactive GAs at low concentrations, using minimal amounts of sample and reducing the use of organic solvents.

  13. [Characterization and comparison of interferon reference standards using UPLC-MS].

    PubMed

    Tao, Lei; Pei, De-ning; Han, Chun-mei; Chen, Wei; Rao, Chun-ming; Wang, Jun-zhi

    2015-01-01

    The study aims to characterize and compare interferon reference standards from 5 manufacturers. By testing molecular mass and trypsin-digested peptide mass mapping, the amino acid sequence was verified and post-translational modifications such as disulfide bond were identified. Results show that the molecular mass and amino acid sequence were consistent with theory; the disulfide bonds of 4 lots of interferon were Cys1-Cys98/Cys29-Cys138, 1 lot was Cys29-Cys139/Cys86-Cys99; N-terminal "+Met", acetyl N-terminal and Met oxidation were identified in part of the sample. UPLC-MS can be used to characterize and compare interferon reference standards from different manufacturers.

  14. Rapid analysis of avenacosides in grain and husks of oats by UPLC-TQ-MS.

    PubMed

    Pecio, Łukasz; Wawrzyniak-Szołkowska, Aleksandra; Oleszek, Wiesław; Stochmal, Anna

    2013-12-01

    Avenacosides A (AA) and B (AB) as well as 26-desglucoavenacoside A (26dAA) were quantified in oats using rapid and sensitive method utilising UPLC-TQ-MS. In the grain, AA and AB were revealed as the primary saponins, whereas in the husks, dAA was predominant. Inconsistent with the published data, observed concentrations of AA and AB in the grain were very similar. Presumably, this is due to higher sensitivity and better selectivity of the mass spectrometry-based quantification method, thus allowing for more precise measurements. Elevated level of an active fungicidal form of saponin, dAA in the husks possibly indicates they are more prone to fungal attacks.

  15. A UPLC-MS Method for Simultaneous Determination of Geniposidic Acid, Two Lignans and Phenolics in Rat Plasma and its Application to Pharmacokinetic Studies of Eucommia ulmoides Extract in Rats.

    PubMed

    Li, Yongjun; Gong, Zipeng; Cao, Xu; Wang, Yonglin; Wang, Aimin; Zheng, Lin; Huang, Yong; Lan, Yanyu

    2016-10-01

    The bark of Eucommia ulmoides is a well-known Chinese herbal medicine that is used to regulate blood pressure and reduce blood sugar and fats, as well as an antioxidant and antimicrobial agent. Here we describe the development of a sensitive ultrahigh performance liquid chromatography-tandem mass spectrum method for the simultaneous determination of five major active ingredients of E. ulmoides bark extract, namely, geniposidic acid (GA), protocatechuic acid (PCA), chlorogenic acid (CA), (+)-pinoresinol di-O-β-D-glucopyranoside (PDG) and (+)-pinoresinol 4'-O-β-D-glucopyranoside (PG), in rat plasma. The preliminary steps in the plasma analysis were the addition of an internal standard and acidification (0.1 % formic acid), followed by protein precipitation with methanol. Separation of the active ingredients was performed on an ACQUITY UPLC® BEH C18 column (2.1 × 50 mm; internal diameter 1.7 µm) at a flow rate of 0.35 mL/min, with acetonitrile/water containing 0.1 % formic acid as the mobile phase. Detection was performed on a triple quadrupole tandem mass spectrometer via electrospray ionization source with positive and negative ionization modes. All calibration curves showed good linearity (r ≥ 0.997) over the concentration range with the low limit of quantification between 4.45 and 54.9 ng/mL. Precision was evaluated by intra- and inter-day assays, and the percentages of the relative standard deviation were all within 15 %. Extraction efficiency and matrix effect were 84.3-102.4 % and 98.1-112.2 %, respectively. The validated method was successfully applied to the pharmacokinetic study in rats after oral administration of E. ulmoides extract. The results indicate that the pharmacokinetic properties of GA differ from those of PCA, CA, PDG and PG, respectively.

  16. UPLC and LC-MS studies on degradation behavior of irinotecan hydrochloride and development of a validated stability-indicating ultra-performance liquid chromatographic method for determination of irinotecan hydrochloride and its impurities in pharmaceutical dosage forms.

    PubMed

    Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Sunil P

    2012-10-01

    The objective of the current investigation was to study the degradation behavior of irinotecan hydrochloride under different International Conference on Harmonization (ICH) recommended stress conditions using ultra-performance liquid chromatography and liquid chromatography-mass spectrometry and to establish a validated stability-indicating reverse-phase ultra-performance liquid chromatographic method for the quantitative determination of irinotecan hydrochloride and its seven impurities and degradation products in pharmaceutical dosage forms. Irinotecan hydrochloride was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Irinotecan hydrochloride was found to degrade significantly in oxidative and base hydrolysis and photolytic degradation conditions. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating power of the method. Chromatographic separation was achieved on a Waters Acquity BEH C8 (100 × 2.1 mm) 1.7-µm column with a mobile phase containing a gradient mixture of solvent A (0.02M KH(2)PO(4) buffer, pH 3.4) and solvent B (a mixture of acetonitrile and methanol in the ratio of 62:38 v/v). The mobile phase was delivered at a flow rate of 0.3 mL/min with ultraviolet detection at 220 nm. The run time was 8 min, within which irinotecan and its seven impurities and degradation products were satisfactorily separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of irinotecan hydrochloride in pharmaceutical dosage forms.

  17. Determination of cannabinoids in whole blood by UPLC-MS-MS.

    PubMed

    Jamey, Carole; Szwarc, Esther; Tracqui, Antoine; Ludes, Bertrand

    2008-06-01

    An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method was developed and validated for the simultaneous determination of Delta(9)-tetrahydrocannabinol (THC), 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH) in whole blood. Samples were prepared by protein precipitation followed by solid-phase extraction. Data were acquired using positive electrospray ionization and multiple reaction monitoring. Two transitions were selected for THC (m/z 315.0 > 193.0 and m/z 315.0 > 122.7) and THC-COOH (m/z 345.0 > 299.0 and m/z 345.0 > 327.0), and one transition was chosen for 11-OH-THC (m/z 331.0 > 313.0). Deuterated analogues of each analyte were used as internal standards for quantification. Run time was 10 min. Limits of quantification (LOQ) were 0.05 ng/mL for THC, 0.1 ng/mL for 11-OH-THC, and 0.2 ng/mL for THC-COOH. Linearity was established from LOQ to 50 ng/mL for each substance (r(2) always > 0.999). Accuracy ranged from 96 to 106%, and imprecision was less than 10% for all analytes. The UPLC-MS-MS method was found to be sensitive, specific, and rapid because it requires no derivatization step. It can be an alternative to gas chromatography-mass spectrometry for the determination of cannabinoids in whole blood.

  18. UPLC-UV method for determination of risedronate in human urine.

    PubMed

    Seo, Young Hwan; Chung, Yoon Hee; Lim, Cheol-Hee; Jeong, Ji Hoon

    2014-08-01

    This study was designed to develop a sensitive and rapid method for the quantitation of risedronate in human urine using ultra-performance liquid chromatography with ultra-violet detector (UPLC-UV) and to compare bioavailability parameter of 5, 35 and 150 mg risedronate. The mobile phase consisted of sodium phosphate buffer, 1 mM etidronate-acetonitrile (95:5, v/v), pH 9.0, and was pumped at a flow rate of 0.3 mL/min. Detection of risedronate in human urine by the UPLC-UV was accurate and precise from 20 ng/mL to 5 μg/mL (a correlation coefficient of 0.99) with 97.16% in mean recovery. The intra-day accuracy was 89.17-110.43% with precision of 0.04-3.16% and the inter-day accuracy was 89.23-110.19% with precision of 1.63-9.72%. Aet (accumulated excretion amount) of risedronate in the urine after 5, 35 and 150 mg administration was 35.08, 246.67 and 1.413.85 μg within 36 h and Umax (maximal excretion rate) was 12.11, 77.7 and 374.24 μg/h, respectively. The assessed dose proportionality of Umax and Aet with three single doses of risedronate was found in an approximately linear manner. These results indicate that the developed simple, rapid and robust assay enables the complete processing of large samples for pharmacokinetic studies of risedronate in biological fluid.

  19. A selective and sensitive method based on UPLC-MS/MS for quantification of momordin Ic in rat plasma: application to a pharmacokinetic study.

    PubMed

    Yan, Huiyu; Song, Yanqing; Zhou, Wei; Zhang, Sixi

    2015-11-10

    A selective and sensitive method was developed and validated based on ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). This method was applied to quantify momordin Ic in rat plasma. Chromatographic separation was performed on a Hypersil GOLD HPLC C18 column (150mm×4.6mm, 5μm) using an isocratic mobile phase of acetonitrile/water (80:20, v/v) at a flow rate of 0.6mL/min. An electrospray ionization source was applied and operated in negative ion mode; selected reaction monitoring (SRM) mode was used for quantification by monitoring the precursor-to-product ion transitions of m/z 763.4→m/z 455.3 for momordin Ic, and m/z 649.4→m/z 487.3 for IS. Calibration curves showed good linearity over the range of 22.0-2200ng/mL for momordin Ic in rat plasma. The developed method was applied to a pharmacokinetic study of momordin Ic in rats after single intravenous doses at 0.52, 1.56, and 4.67mg/kg. The elimination half-life (t1/2) values were 1.22±0.39, 1.14±0.10, and 1.83±0.39h, respectively. The plasma concentration at 2min (C2min) and area under the curve (AUC) for the intravenous doses of momordin Ic were approximately dose proportional.

  20. Development of a rapid and sensitive UPLC-MS/MS assay for the determination of TM-2 in beagle dog plasma and its application to a pharmacokinetic study.

    PubMed

    Lin, Hongli; Zhao, Yunli; Men, Lei; Yang, Mingjing; Liu, Hui; Shao, Yanjie; Wang, Pei; Tang, Xing; Yu, Zhiguo

    2015-01-01

    A simple and sensitive method based on ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of TM-2, which was a novel semi-synthetic taxane derivative in beagle dog plasma. Cabazitaxel was chosen as internal standard. Following extraction by methyl tert-butyl ether, the chromatographic separation was achieved on a Thermo Syncronis C18 column (50 × 2.1 mm, 1.7 µm) by gradient elution within a runtime of 3.5 min. The mobile phase consisted of (A) acetonitrile and (B) 2 mmol/L ammonium acetate in water. The detection was accomplished using positive ion electrospray ionization in multiple reaction monitoring mode. The MS/MS ion transitions were monitored at m/z 812.39 → 551.35 for TM-2 and 836.36 → 555.26 for IS, respectively. The method was linear for TM-2 (r = 0.9924) ranging from 2.5 to 1000 ng/mL. The intra-day and inter-day precisions (relative standard deviation) were within 8.0 and 17.6%, respectively, and the accuracy (relative error) was less than 2.3%. The extraction recovery ranged from 83.1 to 97.1%. The reliable method was successfully applied to a pharmacokinetic study of TM-2 in beagle dogs after intravenous drip with different doses of 0.6, 1.2, and 2.4 mg/kg, respectively.

  1. Simultaneous determination of four furostanol glycosides in rat plasma by UPLC-MS/MS and its application to PK study after oral administration of Dioscorea nipponica extracts.

    PubMed

    Liao, Min; Dai, Cong; Liu, Mengping; Chen, Jiefeng; Chen, Zuanguang; Xie, Zhiyong; Yao, Meicun

    2016-01-05

    A novel, sensitive and rapid ultra-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method for simultaneous quantification of four furostanol glycosides in rat plasma was established and validated. Ginsenoside Rb1 was used as an internal standard. Plasma samples were pretreated by liquid-liquid extraction with n-butanol and chromatographed on a C18 column (2.1×50 mm i.d., 2.6 μm) using a gradient elution program consisting of acetonitrile and water (containing 0.03% formic acid and 0.1 mM lithium acetate) at a flow rate of 0.4 mL/min. Lithium adduct ions were employed to enhance the response of the analytes in electrospray positive ionization mode and multiple reaction monitoring transitions were performed for detection. All calibration curves exhibited good linearity (r>0.999) over the range of 10-20,000 ng/mL for protodioscin and 2-4000 ng/mL for protogracillin, pseudoprotodioscin and pseudoprotogracillin. The recoveries of the whole analytes were more than 80.3% and exhibited no severe matrix effect. Meanwhile, the intra- and inter-day precisions were all less than 10.7% and accuracies were within the range of -8.1-12.9%. The four saponins showed rapid excretion and relative high plasma concentrations when the validated method was applied to the PK study of Dioscorea nipponica extracts by intragastric administration at low, medium and high dose to rats. Moreover, the T(1/2) and AUC(0-t) of each compound turned out to behave in a dose-dependent pattern by comparing them at different dose levels.

  2. FRACTIONATING COLUMN PRODUCT COLLECTOR CONTROL

    DOEpatents

    Paxson, G.D. Jr.

    1964-03-10

    Means for detecting minute fluid products from a chemical separation column and for advancing a collector tube rack in order to automatically separate and collect successive fractionated products are described. A charge is imposed on the forming drops at the column orifice to create an electric field as the drop falls in the vicinity of a sensing plate. The field is detected by an electrometer tube coupled to the plate causing an output signal to actuate rotation of a collector turntable rack, thereby positioning new collectors under the orifice. The invention provides reliable automatic collection independent of drop size, rate of fall, or chemical composition. (AEC)

  3. Chromatographic properties PLOT multicapillary columns.

    PubMed

    Nikolaeva, O A; Patrushev, Y V; Sidelnikov, V N

    2017-03-10

    Multicapillary columns (MCCs) for gas chromatography make it possible to perform high-speed analysis of the mixtures of gaseous and volatile substances at a relatively large amount of the loaded sample. The study was performed using PLOT MCCs for gas-solid chromatography (GSC) with different stationary phases (SP) based on alumina, silica and poly-(1-trimethylsilyl-1-propyne) (PTMSP) polymer as well as porous polymers divinylbenzene-styrene (DVB-St), divinylbenzene-vinylimidazole (DVB-VIm) and divinylbenzene-ethylene glycol dimethacrylate (DVB-EGD). These MCCs have the efficiency of 4000-10000 theoretical plates per meter (TP/m) and at a column length of 25-30cm can separate within 10-20s multicomponent mixtures of substances belonging to different classes of chemical compounds. The sample amount not overloading the column is 0.03-1μg and depends on the features of a porous layer. Examples of separations on some of the studied columns are considered.

  4. Determination of Curcuminoids in Curcuma longa Linn. by UPLC/Q-TOF-MS: An Application in Turmeric Cultivation.

    PubMed

    Ashraf, Kamran; Mujeeb, Mohd; Ahmad, Altaf; Ahmad, Niyaz; Amir, Mohd

    2015-09-01

    Cucuma longa Linn. (Fam-Zingiberaceae) is a valued medicinal plant contains curcuminoids (curcumin, demethoxycurcumin and bisdemethoxycurcumin) as major bioactive constituents. Previously reported analytical methods for analysis of curcuminoids were found to suffer from low resolution, lower sensitivity and longer analytical times. In this study, a rapid, sensitive, selective high-throughput ultra high performance liquid chromatography-tandem mass spectrometry (UPLC/Q-TOF-MS) method was developed and validated for the quantification of curcuminoids with an aim to reduce analysis time and enhance efficiency. UPLC/Q-TOF-MS analysis showed large variation (1.408-5.027% w/w) of curcuminoids among different samples with respect to their occurrence of metabolite and their concentration. The results showed that Erode (south province) contains highest quantity of curcuminoids and concluded to be the superior varieties. The results obtained here could be valuable for devising strategies for cultivating this medicinal plant.

  5. [Authentication and ultra performance liquid chromatography (UPLC)/MS analysis of magic mint, Salvia divinorum and its related plants].

    PubMed

    Maruyama, Takuro; Kamakura, Hiroyuki; Kikura-Hanajiri, Ruri; Goda, Yukihiro

    2008-01-01

    Ultra performance liquid chromatography (UPLC)/mass spectrometry (MS) analysis was performed to investigate whether commercial Salvia cultivars available in the Japanese market contain salvinorin A (1), which is an hallucinogen present in magic mint (Salvia divinorum) prior to the regulation of S. divinorum by the Japanese Pharmaceutical Affairs Law. In addition, a previously reported method to authenticate S. divinorum, utilizing an amplification refractory mutation system (ARMS) was applied to the same samples to estimate the method's accuracy. As a result of the UPLC/MS analysis, it was clear that none of the tested cultivars possessed 1 while S. divinorum leaves and its processed products "concentrated salvia" contained 1 in the range from 0.19% to 0.58%. Furthermore, the ARMS method could clearly distinguish S. divinorum from the tested cultivars. In conclusion, the authentication method is considered to be useful for the practical regulation of S. divinorum due to its simplicity and accuracy.

  6. Quantitative determination of betamethasone sodium phosphate and betamethasone dipropionate in human plasma by UPLC-MS/MS and a bioequivalence study.

    PubMed

    Chen, Man-Yun; Tang, Yong-Jun; Wang, Yi-Cheng; Wang, Chong-Zhi; Yuan, Chun-Su; Chen, Yao; Tan, Zhi-Rong; Huang, Wei-Hua; Zhou, Hong-Hao

    2016-05-07

    The compound medicine of betamethasone sodium phosphate (BSP) and betamethasone dipropionate (BDP) is widely used for diverse glucocorticoid-sensitive acute and chronic diseases such as asthma, rheumatoid arthritis and systemic lupus erythematosus. It will be useful and beneficial to validate sensitive method for the determination of BSP, BDP and their metabolites for their pharmacokinetic study. Hereby, an ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been validated for the determination of BSP, BDP and their metabolites betamethasone (BOH), betamethasone 17-monodipropionate (B17P) and betamethasone 21-monodipropionate (B21P) in human plasma. Liquid-liquid extraction with ether and n-hexane (v/v, 4:1) was used for sample preparation of BDP, BOH, B17P and B21P with beclomethasone dipropionate as internal standard (IS), while solid phase extraction was adopted for sample preparation of BSP using prednisolone as IS. The chromatographic separation was performed on a Hypurity C18 column (150 mm×2.1 mm, 5 μm) for BOH, BDP, B21P and B17P, and a Luna C18 (2) column (150 mm×2.0 mm, 5 μm) for BSP. Electrospray ionization interfaced with positive multiple reaction monitoring (MRM) scan mode was used for mass spectrometric detection. The standard calibration curves were linear within the range of 2.525 × 10(-9)-403.9 × 10(-9) mol·dm(-3) for BSP, 0.125 × 10(-9)-55.81 × 10(-9) mol·dm(-3) for BDP, 0.278 × 10(-9)-74.95 × 10(-9) mol·dm(-3) for BOH, 0.098 × 10(-9)-4.688 × 10(-9) mol·dm(-3) for B17P and 0.226 × 10(-9)-5.411 × 10(-9) mol·dm(-3) for B21P, respectively. The validated method was successfully applied to a bioequivalence study in 23 healthy subjects after they were injected with this compound medicine BSP and BDP.

  7. Quantitative determination of betamethasone sodium phosphate and betamethasone dipropionate in human plasma by UPLC-MS/MS and a bioequivalence study

    PubMed Central

    Chen, Man-Yun; Tang, Yong-Jun; Wang, Yi-Cheng; Wang, Chong-Zhi; Yuan, Chun-Su; Chen, Yao; Tan, Zhi-Rong; Huang, Wei-Hua; Zhou, Hong-Hao

    2016-01-01

    The compound medicine of betamethasone sodium phosphate (BSP) and betamethasone dipropionate (BDP) is widely used for diverse glucocorticoid-sensitive acute and chronic diseases such as asthma, rheumatoid arthritis and systemic lupus erythematosus. It will be useful and beneficial to validate sensitive method for the determination of BSP, BDP and their metabolites for their pharmacokinetic study. Hereby, an ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been validated for the determination of BSP, BDP and their metabolites betamethasone (BOH), betamethasone 17-monodipropionate (B17P) and betamethasone 21-monodipropionate (B21P) in human plasma. Liquid-liquid extraction with ether and n-hexane (v/v, 4:1) was used for sample preparation of BDP, BOH, B17P and B21P with beclomethasone dipropionate as internal standard (IS), while solid phase extraction was adopted for sample preparation of BSP using prednisolone as IS. The chromatographic separation was performed on a Hypurity C18 column (150 mm×2.1 mm, 5 μm) for BOH, BDP, B21P and B17P, and a Luna C18 (2) column (150 mm×2.0 mm, 5 μm) for BSP. Electrospray ionization interfaced with positive multiple reaction monitoring (MRM) scan mode was used for mass spectrometric detection. The standard calibration curves were linear within the range of 2.525 × 10−9−403.9 × 10−9 mol·dm−3 for BSP, 0.125 × 10−9−55.81 × 10−9 mol·dm−3 for BDP, 0.278 × 10−9−74.95 × 10−9 mol·dm−3 for BOH, 0.098 × 10−9−4.688 × 10−9 mol·dm−3 for B17P and 0.226 × 10−9−5.411 × 10−9 mol·dm−3 for B21P, respectively. The validated method was successfully applied to a bioequivalence study in 23 healthy subjects after they were injected with this compound medicine BSP and BDP. PMID:27695531

  8. Quantitative and chemical fingerprint analysis for quality control of rhizoma Coptidischinensis based on UPLC-PAD combined with chemometrics methods.

    PubMed

    Kong, Wei-Jun; Zhao, Yan-Ling; Xiao, Xiao-He; Jin, Cheng; Li, Zu-Lun

    2009-10-01

    To control the quality of rhizoma Coptidis, a method based on ultra performance liquid chromatography with photodiode array detector (UPLC-PAD) was developed for quantitative analysis of five active alkaloids and chemical fingerprint analysis. In quantitative analysis, the five alkaloids showed good regression (R > 0.9992) within test ranges and the recovery of the method was in the range of 98.4-100.8%. The limit of detections and quantifications for five alkaloids in PAD were less than 0.07 and 0.22 microg/ml, respectively. In order to compare the UPLC fingerprints between rhizoma Coptidis from different origins, the chemometrics procedures, including similarity analysis (SA), hierarchical clustering analysis (HCA), principal component analysis (PCA) were applied to classify the rhizoma Coptidis samples according to their cultivated origins. Consistent results were obtained to show that rhizoma Coptidis samples could be successfully grouped in accordance with the province of origin. Furthermore, five marker constituents were screened out to be the main chemical marker, which could be applied to accurate discrimination and quality control for rhizoma Coptidis by quantitative analysis. This study revealed that UPLC-PAD method was simple, sensitive and reliable for quantitative and chemical fingerprint analysis, moreover, for the quality evaluation and control of rhizoma Coptidis.

  9. Column

    ERIC Educational Resources Information Center

    Education in Chemistry, 1973

    1973-01-01

    Articles are included concerning industry and schools, science and mathematics award scheme, teaching and research, safety, inservice training, Ugandan chemistry, plastics, and 19th century Nuffield. (DF)

  10. Evaluation of the content variation of anthraquinone glycosides in rhubarb by UPLC-PDA

    PubMed Central

    2013-01-01

    Background Rhubarb is an important Chinese medicinal herb with a long history of over 2000 years and has been commonly used as a laxative. It is the radix and rhizome of Rheum officinale Baill., R. palmatum L. and R. tanguticum Maxim, all of which are mainly distributed in a broad region in the Tibetan plateau. Anthraquinone glycosides are a series of major active ingredients found in all three species. They are key intermediates in the anthraquinone secondary metabolism and the sennnoside biosynthesis. The variation of the anthraquinone glycoside content in rhubarb in response to specific factors remains an attractive topic. Results A simple and sensitive Ultra Performance Liquid Chromatography with Photo-Diode Array (UPLC-PDA) detector was developed for the simultaneous determination of six anthraquinone glycosides in rhubarb, i.e., aloeemodin-8-O-glucoside, rhein-8-O-glucoside, chrysophanol-1-O-glucoside, emodin-1-O-glucoside, chrysophanol-8-O-glucoside, emodin-8-O-glucoside. Twenty-seven batches from three species were submitted to the multi-component analysis. The results showed that the anthraquinone glycoside content varied significantly even within the same species. The results showed that the anthraquinone glycoside content varied significantly within the same species but not between different species. The PCA and content analysis results confirmed that the plant species has no obvious effect on the content variation. Neither was any significant correlation observed between the anthraquinone glycoside content and the geographic distribution of the rhubarb. Through correlational analysis, altitude was found to be the main factor that affects the anthraquinone glycoside content in rhubarb. Rhubarb grown at higher altitude has higher anthraquinone glycoside content. Conclusions This work provides a rapid, sensitive and accurate UPLC-PDA method for the simultaneous determination of six anthraquinone glycosides in rhubarb. The anthraquinone glycoside content

  11. Beam Studies with Electron Columns

    SciTech Connect

    Shiltsev, V.; Valishev, A.; Kuznetsov, G.; Kamerdzhiev, V.; Romanov, A.; /Novosibirsk, IYF

    2009-04-01

    We report preliminary results of experimental studies of 'electron columns' in the Tevatron and in a specialized test setup. In the Tevatron, a beam of 150 GeV protons ionizes residual gas and ionization electrons are stored in an electrostatic trap immersed into strong longitudinal magnetic field. Shifts of proton betatron frequencies are observed. In the test setup, we observe effects pointing to accumulation and escape of ionization electrons.

  12. Stability of elastically supported columns

    NASA Technical Reports Server (NTRS)

    Niles, Alfred S; Viscovich, Steven J

    1942-01-01

    A criterion is developed for the stiffness required of elastic lateral supports at the ends of a compression member to provide stability. A method based on this criterion is then developed for checking the stability of a continuous beam-column. A related method is also developed for checking the stability of a member of a pin-jointed truss against rotation in the plane of the truss.

  13. Method for packed column separations and purifications

    DOEpatents

    Holman, David A.; Bruckner-Lea, Cynthia J.; Brockman, Fred J.; Chandler, Darrell P.

    2006-08-15

    The invention encompasses a method of packing and unpacking a column chamber. A mixture of a fluid and a matrix material are introduced through a column chamber inlet so that the matrix material is packed within a column chamber to form a packed column. The column chamber having the column chamber inlet or first port for receiving the mixture further has an outlet port and an actuator port. The outlet port is partially closed for capturing the matrix material and permitting the fluid to flow therepast by rotating relative one to the other of a rod placed in the actuator port. Further rotation relative one to the other of the rod and the column chamber opens the outlet and permits the matrix material and the fluid to flow therethrough thereby unpacking the matrix material from the column chamber.

  14. UPLC-ESI-TOF MS-Based Metabolite Profiling of the Antioxidative Food Supplement Garcinia buchananii.

    PubMed

    Stark, Timo D; Lösch, Sofie; Wakamatsu, Junichiro; Balemba, Onesmo B; Frank, Oliver; Hofmann, Thomas

    2015-08-19

    Comparative antioxidative analyses of aqueous ethanolic extracts from leaf, root, and stem of Garcinia buchananii revealed high activity of all three organs. To investigate the metabolite composition of the different parts of G. buchananii, an untargeted metabolomics approach using UPLC-ESI-TOF MS with simultaneous acquisition of low- and high-collision energy mass spectra (MS(e)) was performed. Unsupervised statistics (PCA) highlighted clear differences in the metabolomes of the three organs. OPLS-DA revealed (2R,3S,2″R,3″R)-GB-1, (2R,3S)-morelloflavone, and (2R,3S)-volkensiflavone as the most decisive marker compounds discriminating leaf from root and stem extract. Leaves represent the best source to isolate GB-1, morelloflavone, and volkensiflavone. Root extract is the best organ to isolate xanthones and stem bark extract the best source to isolate (2R,3S,2″R,3″R)-manniflavanone; the identified polyisoprenylated benzophenones are characteristic compounds for the leaf organ. Morelloflavone, volkensiflavone, and garcicowin C were isolated for the first time from G. buchananii, identified via MS, NMR, and CD spectroscopy, and showed in H2O2 scavenging, H/L-TEAC, and H/L-ORAC assays moderate to strong in vitro antioxidative activities.

  15. Photocatalytic degradation of hexazinone and its determination in water via UPLC-MS/MS.

    PubMed

    Mei, Mei; Du, Zhenxia; Xu, Ruifen; Chen, Yun; Zhang, Haojie; Qu, Shuping

    2012-06-30

    Degradation of hexazinone has been investigated by means of photocatalysis of mixed-phase crystal nano-TiO(2). Influences of adsorption, amount of nano-TiO(2), pH and irradiation time on the photocatalytic process are studied. Results show that hexazinone is totally degraded within 40min of irradiation under pH neutral conditions. This compares favorably with Degussa P25 TiO(2) when conducted under the same experimental conditions. Preliminary photocatalytic kinetic information for hexazinone degradation is proposed. First order kinetics is obtained for the adsorption and photocatalytic degradation reactions, which fit the Langmuir-Hinshelwood model. A rapid, sensitive and accurate UPLC-MS/MS technique is developed and utilized to determine the level of hexazinone in water in support of the degradation kinetics study. The results indicate a limit of detection (LOD) at 0.05μg/l and the recoveries between 90.2 and 98.5% with relative standard deviations (RSD) lower than 12%. A LC-MS/MS technique is used to trace the degradation process. Complete degradation is achieved into final products including nontoxic water, carbon dioxide and urea. A probable pathway for the total photocatalytic degradation of hexazinone is proposed.

  16. Quantification of flavonol glycosides in Camellia sinensis by MRM mode of UPLC-QQQ-MS/MS.

    PubMed

    Wu, Yahui; Jiang, Xiaolan; Zhang, Shuxiang; Dai, Xinlong; Liu, Yajun; Tan, Huarong; Gao, Liping; Xia, Tao

    2016-04-01

    Phenolic compounds are major components of tea flavour, in which catechins and flavonol glycosides play important roles in the astringent taste of tea infusion. However, the flavonol glycosides are difficult to quantify because of the large variety, as well as the inefficient seperation on chromatography. In this paper, a total of 15 flavonol glycosides in the tea plant (Camellia sinensis) were identified by the high performance liquid chromatography (HPLC) coupled to a time-of-flight mass spectrometer (TOF-MS), and a quantitative method was established based on multiple reaction monitoring (MRM) mode of ultra-high performance liquid chromatography (UPLC) coupled to a triple quadrupole mass spectrometer (QQQ-MS/MS). It provided the limit of detection and quantification to the order of picogram, which was more sensitive than the HPLC detection of the order of nanogram. The relative standard deviations of the intra- and inter-day variations in retention time and signal intensity (peak area) of six analytes were less than 0.26% and 4%, respectively. The flavonol glycosides of four tea cultivars were relatively quantified using the signal intensity (peak area) of product ion, in which six flavonol glycosides were quantified by the authentic standards. The results showed that the flavonol mono-, di- and tri-glycoside mostly accumulated in young leaves of the four tea cultivars. Notably, the myricetin 3-O-galactoside was the major component among the six flavonol glycosides detected.

  17. UPLC Separation and QTof–MS Identification of Major Alkaloids in Plumula Nelumbinis

    PubMed Central

    Lin, Zongtao; Yang, Ruinan; Guan, Zheng; Chen, Ailiang; Li, Wei

    2016-01-01

    Introduction As an essential medicine and tea source in many countries, Plumula Nelumbinis potentially exerts its major biological activities through its alkaloids. However, its activities are not fully understood due to the lack of studies on its chemical components. Objective To establish an Ultra Performance Liquid Chromatography–Diode-Array Detector (UPLC–DAD) method, combined with an Electrospray Ionization–Quadrupole Time-of-flight Mass Spectrometry (ESI–QTof MS), for the separation and identification of Plumula Nelumbinis alkaloids. Methods The eluant from an UPLC separation of an ethanol extract of Plumula Nelumbinis was directly infused into an ESI–QTof MS system. Both positive and negative ion modes of ESI with low and high Collision Energy (CE) were used to obtain sufficient MS information. Results 21 alkaloids were tentatively identified based on their chromatographic characteristics, UV spectra, exact mass, MS fragments, and literature reports. They consist of 6 bis-1-benzyltetrahydroisoquinoline, 11 benzyltetrahydroisoquinoline (containing 2 glycoalkaloids and 2 quaternary ammoniums), 2 aporphine, one proaporphine, and one indole alkaloids. Eleven were identified in Plumula Nelumbinis for the first time and 7 were firstly reported in Nelumbo nucifera Gaertn. Five compounds, namely norcoclaurine-4′-O-glucoside, norcoclaurine-6-O-glucoside, isolotusine, 6-demethyl-4′-methyl-N-methylcoclaurine and N-norisoliensinine, were characterized and proposed as new compounds. Conclusion The established UPLC–DAD–ESI–QTof–MS method is efficient for systematic identification of the alkaloids in Plumula Nelumbinis extract. PMID:24733684

  18. Alkaloids in Erythrina by UPLC-ESI-MS and In Vivo Hypotensive Potential of Extractive Preparations

    PubMed Central

    Merlugo, Liara; Santos, Marí C.; Sant'Anna, Liane S.; Cordeiro, Everson W. F.; Batista, Luiz A. C.; Miotto, Silvia T. S.; Garcia, Cássia V.; Moreira, Cleci M.; Mendez, Andreas S. L.

    2015-01-01

    Erythrina species are used in popular medicine as sedative, anxiolytic, anti-inflammatory, and antihypertensive. In this work, we investigated the chemical composition of extracts obtained from leaves of E. falcata and E. crista-galli. The hypotensive potential of E. falcata and the mechanism of action were also studied. The extracts were obtained by maceration and infusion. The total content of phenolic compounds and flavonoids was estimated by spectrophotometric methods. The chemical constituents were studied performing a chromatographic analysis by UPLC-ESI-MS. For in vivo protocols, blood pressure and heart rate were measured by the invasive hemodynamic monitoring method. Different concentrations of extracts and drugs such as L-NAME, losartan, hexamethonium, and propranolol were administrated i.v. The results of total phenolic contents for E. falcata and E. crista-galli were 1.3193–1.4989 mgGAE/mL for maceration and 0.8771–0.9506 mgGAE/mL for infusion. In total flavonoids, the content was 7.7829–8.1976 mg RE/g for maceration and 9.3471–10.4765 RE mg/g for infusion. The chemical composition was based on alkaloids, suggesting the presence of erythristemine, 11β-methoxyglucoerysodine, erysothiopine, 11β-hydroxyerysodine-glucose, and 11-hydroxyerysotinone-rhamnoside. A potent dose-dependent hypotensive effect was observed for E. falcata, which may be related to the route of β-adrenergic receptors. PMID:26356581

  19. Analysis of phospholipids in microalga Nitzschia closterium by UPLC-Q-TOF-MS

    NASA Astrophysics Data System (ADS)

    Yan, Xiaojun; Li, Haiying; Xu, Jilin; Zhou, Chengxu

    2010-01-01

    Precise structural identification of phospholipids in the microalga Nitzschia closterium has been established using ultra performance liquid chromatography-electrospray ionization-quadrupole-time of flight-mass spectrometry (UPLC-ESI-Q-TOF-MS) for direct analysis of total lipid extracts. Mass spectrometry was performed in reflective time-of-flight using electron spraying ionization in negative mode. Phospholipid molecular species identification was based on the characteristic product ions and neutral loss yielded by different phospholipids under ESI-MS/MS mode. The molecular species were confirmed by the carboxylate anions produced by phospholipids in negative mode; the regiospecificity of the two acyl chains was determined from the ratio of sn-1 to sn-2 carboxylate anion abundances. As a result, 18 lipid molecular species were identified for the first time in this microalga, comprising seven phosphatidylcholines (PC), two phosphatidylethanolamines (PE), two phosphatidylinositols (PI), and seven phosphatidylglycerols (PG). Lipid standards of PC, PE, PI, and PG were added to the total lipids as internal standards for semiquantitative analysis, revealing concentrations of phospholipids in this species between 0.09 and 3.37 nmol/mg. This method can produce a full structural profile of intact phospholipid molecular species and can be used for study of the physiological and ecological functions of lipids by monitoring their individual changes over time.

  20. Qualitative and quantitative analyses of alkaloids in Uncaria species by UPLC-ESI-Q-TOF/MS.

    PubMed

    Wang, Hai-Bo; Qi, Wen; Zhang, Lin; Yuan, Dan

    2014-01-01

    An ultra performance liquid chromatography (UPLC) coupled with quadrupole time-of-flight mass spectrometry (Q-TOF/MS) method has been optimized and established for the rapid analysis of the alkaloids in 22 samples originating from five Uncaria (U.) species. The accurate mass measurement of all the protonated molecules and subsequent fragment ions offers higher quality structural information for the interpretation of fragmentation pathways of the various groups of alkaloids. A total of 19 oxindole alkaloids, 16 indole alkaloids and 1 flavone were identified by co-chromatography of the sample extract with authentic standards, comparison of the retention time, characteristic molecular ions and fragment ions, or were tentatively identified by MS/MS determination. Moreover, the method was validated for the simultaneous quantification of the 24 components within 10.5 min. The potential chemical markers were identified for classification of the U. species samples by principal component analysis (PCA) and orthogonal partial least squared discriminant analysis (OPLS-DA). The results demonstrate the similarity and differences in alkaloids among the five U. species, which is helpful for the standardization and quality control of the medical materials of the U. Ramulus Cum Unics (URCU). Furthermore, with multivariate statistical analysis, the determined markers are more definite and useful for chemotaxonomy of the U. genus.

  1. Classification of Opium by UPLC-Q-TOF Analysis of Principal and Minor Alkaloids.

    PubMed

    Liu, Cuimei; Hua, Zhendong; Bai, Yanping

    2016-11-01

    Opium is the raw material for the production of heroin, and the characterization of opium seizures through laboratory analysis is a valuable tool for law enforcement agencies to trace clandestine opium production and trafficking. In this work, a method for opium profiling based on the relative content of five principal and 14 minor opium alkaloids was developed and validated. UPLC-Q-TOF was adopted in alkaloid analysis for its high selectivity and sensitivity, which facilitated the sample preparation and testing. The authentic sample set consisted of 100 "Myanmar" and 45 "Afghanistan" opium seizures; based on the data set of the 19 alkaloid variables in them, a partial least squares discriminant analysis classification model was successfully achieved. Minor alkaloids were found to be vitally important for opium profiling, although combined use of both principal and minor alkaloids resulted in the best geographical classification result. The developed method realized a simple and accurate way to differentiate opium from Myanmar and Afghanistan, which may find wide application in forensic laboratories.

  2. Comparative analysis of diosgenin in Dioscorea species and related medicinal plants by UPLC-DAD-MS

    PubMed Central

    2014-01-01

    Background Dioscorea is a genus of flowering plants, and some Dioscorea species are known and used as a source for the steroidal sapogenin diosgenin. To screen potential resource from Dioscorea species and related medicinal plants for diosgenin extraction, a rapid method to compare the contents of diosgenin in various plants is crucial. Results An ultra-performance liquid chromatography (UPLC) coupled with diode array detection (DAD) and electrospray ionization mass spectrometry (ESI-MS) method was developed for identification and determination of diosgenin in various plants. A comprehensive validation of the developed method was conducted. Twenty-four batches of plant samples from four Dioscorea species, one Smilax species and two Heterosmilax species were analyzed by using the developed method. The present method presented good sensitivity, precision and accuracy. Diosgenin was found in three Dioscorea species and one Heterosmilax species, namely D. zingiberensis, D. septemloba, D. collettii and H. yunnanensis. Conclusion The method is suitable for the screening of diosgenin resources from plants. D. zingiberensis is an important resource for diosgenin harvesting. PMID:25107333

  3. Degradation Pathway for Eplerenone by Validated Stability Indicating UP-LC Method.

    PubMed

    Sudhakar Babu, Kondru; Madireddy, Venkataramanna; Indukuri, Venkata Somaraju

    2012-01-01

    Degradation pathway for eplerenone is established as per ICH recommendations by validated and stability-indicating reverse phase liquid chromatographic method. Eplerenone is subjected to stress conditions of acid, base, oxidation, and thermal and photolysis. Significant degradation is observed in acid and base stress conditions. Four impurities are studied and the major degradant (RRT about 0.31) was identified by LC-MS and spectral analysis. The stress samples are assayed against a qualified reference standard and the mass balance is found close to 99.5%. Efficient chromatographic separation is achieved on a Waters symmetry C18 stationary phase with simple mobile phase combination delivered in gradient mode and quantification is carried at 240 nm at a flow rate of 1.0 mL min(-1). In the developed LC method the resolution between eplerenone and four potential impurities (imp-1, imp-2, imp-3, and imp-4) is found to be greater than 4.0. Regression analysis shows an r value (correlation coefficient) of greater than 0.999 for eplerenone and four potential impurities. This method is capable to detect the impurities of eplerenone at a level of 0.020% with respect to test concentration of 1.0 mg mL(-1) for a 20 μL injection volume. The developed UPLC method is validated with respect to specificity, linearity and range, accuracy, precision, and robustness for impurities and assay determination.

  4. Identification of astilbin metabolites produced by human intestinal bacteria using UPLC-Q-TOF/MS.

    PubMed

    Zhao, Min; Xu, Jun; Qian, Dawei; Guo, Jianming; Jiang, Shu; Shang, Er-xin; Duan, Jin-ao

    2014-07-01

    Astilbin, mainly isolated from a commonly used herbal medicine, Smilax glabra Roxb (SGR), exhibits a variety of pharmacological activities and biological effects. It is metabolized by intestinal bacteria after oral administration which leads to the variation of ethnopharmacological profile of this traditional medicine. However, little is known on the interactions of this active compound with intestinal bacteria, which would be very helpful in unravelling how SGR works. In this study, different pure bacteria from human feces were isolated and were used to investigate their conversion capability of astilbin. Ultra-performance liquid chromatography/quadrupole-time-of-flight mass spectrometry (UPLC-Q-TOF/MS) technique combined with Metabolynx(TM) software was used to analyze astilbin and its metabolites. The parent compound and two metabolites (quercetin and eriodictyol) were detected in the isolated bacterial samples compared with blank samples. Quercetin was present in Enterococcus sp. 8B, 8-2 and 9-2 samples. Eriodictyol was only identified in Enterococcus sp. 8B sample. The metabolic routes and metabolites of astilbin produced by the different intestinal bacteria are reported for the first time. This will be useful for the investigation of the pharmacokinetic study of astilbin in vivo and the role of different intestinal bacteria in the metabolism of natural compounds.

  5. Temperature programmable microfabricated gas chromatography column

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.

    2003-12-23

    A temperature programmable microfabricated gas chromatography column enables more efficient chemical separation of chemical analytes in a gas mixture by the integration of a resistive heating element and temperature sensing on the microfabricated column. Additionally, means are provided to thermally isolate the heated column from their surroundings. The small heat capacity and thermal isolation of the microfabricated column improves the thermal time response and power consumption, both important factors for portable microanalytical systems.

  6. [Simultaneous determination of artificial sweeteners in beverage by ultra performance liquid chromatography].

    PubMed

    Ji, Chao; Sun, Yanyan; Li, Xiuqin; Chu, Xiaogang; Chen, Zhengxing

    2009-01-01

    An ultra performance liquid chromatographic (UPLC) method for the simultaneous separation and determination of four artificial sweeteners (sodium saccharin, aspartame, acesulfame and neotame) in a single injection was developed. The separation was performed on an ACQUITY UPLC BEH C18 column with gradient program and detection at 220 nm. The good linearities between the concentrations of all analytes and peak area responses were achieved over the range from 0.5 to 20.0 mg/L. The average recoveries in samples were 80.5% - 95.2% with the relative standard deviations of 0.50% - 8.7%. The method has been successfully applied to the determination of the four sweeteners in drinks and powdered tabletop sweeteners.

  7. Dry-Column Flash Chromatography

    NASA Astrophysics Data System (ADS)

    Shusterman, Alan J.; McDougal, Patrick G.; Glasfeld, Arthur

    1997-10-01

    Dry-column flash chromatography is a safe, powerful, yet easily learned preparative chromatography technique. It has proven useful in research, and an adaptation of the technique for use in large teaching laboratories (general chemistry, organic chemistry) is described here. The student version is similar to vacuum filtration, uses the same compact, readily available glassware, and inexpensive and safe solvents (ethyl acetate and hexane) and adsorbent (Merck grade 60 silica gel). The technique is sufficiently simple and powerful that a beginning student can successfully resolve diastereomers on sample scales ranging from 100 mg to >1 g.

  8. Elastic stability of non-uniform columns

    NASA Astrophysics Data System (ADS)

    Lee, S. Y.; Kuo, Y. H.

    1991-07-01

    A simple and efficient method is proposed to investigate the elastic stability of three different tapered columns subjected to uniformly distributed follower forces. The influences of the boundary conditions and taper ratio on critical buckling loads are investigated. The critical buckling loads of columns of rectangular cross section with constant depth and linearly varied width ( T1), constant width and linearly varied depth ( T2) and double taper ( T3) are investigated. Among the three different non-uniform columns considered, taper ratio has the greatest influence on the critical buckling load of column T3 and the lowest influence on that of column T1. The types of instability mechanisms for hinged-hinged and cantilever non-uniform columns are divergence and flutter respectively. However, for clamped-hinged and clamped-clamped non-uniform columns, the type of instability mechanism for column T1 is divergence, while that for columns T2 and T3 is divergence only when the taper ratio of the columns is greater than certain critical values and flutter for the rest value of taper ratio. When the type of instability mechanism changes from divergence to flutter, there is a finite jump for the critical buckling load. The influence of taper ratio on the elastic stability of cantilever column T3 is very sensitive for small values of the taper ratio and there also exist some discontinieties in the critical buckling loads of flutter instability. For a hinged-hinged non-uniform column ( T2 or T3) with a rotational spring at the left end of the column, when the taper ratio is less than the critical value the instability mechanism changes from divergence to flutter as the rotational spring constant is increased. For a clamped-elastically supported non-uniform column, when the taper ratio is greater than the critical value the instability mechanism changes from flutter to divergence as the translational spring constant is increased.

  9. Quantitative UPLC-MS/MS assay of urinary 2,8-dihydroxyadenine for diagnosis and management of adenine phosphoribosyltransferase deficiency.

    PubMed

    Thorsteinsdottir, Margret; Thorsteinsdottir, Unnur A; Eiriksson, Finnur F; Runolfsdottir, Hrafnhildur L; Agustsdottir, Inger M Sch; Oddsdottir, Steinunn; Sigurdsson, Baldur B; Hardarson, Hordur K; Kamble, Nilesh R; Sigurdsson, Snorri Th; Edvardsson, Vidar O; Palsson, Runolfur

    2016-11-15

    Adenine phosphoribosyltransferase (APRT) deficiency is a hereditary disorder that leads to excessive urinary excretion of 2,8-dihydroxyadenine (DHA), causing nephrolithiasis and chronic kidney disease. Treatment with allopurinol or febuxostat reduces DHA production and attenuates the renal manifestations. Assessment of DHA crystalluria by urine microscopy is used for therapeutic monitoring, but lacks sensitivity. We report a high-throughput assay based on ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) for quantification of urinary DHA. The UPLC-MS/MS assay was optimized by a chemometric approach for absolute quantification of DHA, utilizing isotopically labeled DHA as an internal standard. Experimental screening was conducted with D-optimal design and optimization of the DHA response was performed with central composite face design and related to the peak area of DHA using partial least square regression. Acceptable precision and accuracy of the DHA concentration were obtained over a calibration range of 100 to 5000ng/mL on three different days. The intra- and inter-day accuracy and precision coefficients of variation were well within ±15% for quality control samples analyzed in replicates of six at three concentration levels. Absolute quantification of DHA in urine samples from patients with APRT deficiency was achieved wihtin 6.5min. Measurement of DHA in 24h urine samples from three patients with APRT deficiency, diluted 1:15 (v/v) with 10mM ammonium hydroxide (NH4OH), yielded a concentration of 3021, 5860 and 10563ng/mL and 24h excretion of 816, 1327 and 1649mg, respectively. A rapid and robust UPLC-MS/MS assay for absolute quantification of DHA in urine was successfully developed. We believe this method will greatly facilitate diagnosis and management of patients with APRT deficiency.

  10. Optimisation of ultra-performance LC conditions using response surface methodology for rapid separation and quantitative determination of phenolic compounds in Artemisia minor.

    PubMed

    Zhou, Yan; Fung-Kei Choi, Franky; He, Zhi Zhou; Song, Jing-Zheng; Qiao, Chun-Feng; Liu, Xin; Ding, Li-Sheng; Gesang, Suo-Lang; Xu, Hong-Xi

    2010-12-01

    A method that couples rapid, sensitive, reproducible and accurate ultra-performance LC (UPLC) with quadrupole-TOF-MS was established for the first simultaneous qualitative and quantitative analysis of phenolic compounds in Artemisia minor. Box-Behnken designs (BBDs) were applied as an effective tool to optimise major parameters that influence the resolution of UPLC, including three gradient steps and column temperature. Under optimal UPLC conditions, a total of 23 phenolic compounds in the crude methanol extracts of A. minor were well separated on a Waters Acquity UPLC BEH C(18) column (100×2.1 mm, 1.7 μm particle size) within 16.5 min, and the compounds were unequivocally or tentatively identified via comparisons with authentic standards and literature. In this study, a total of six major phenolic compounds were quantified in A. minor and the method was validated to be sensitive, precise and accurate within the LOD from 1.24 to 5.27 μg/mL, and the overall intra- and inter-day variations in detection were less than 3.76%. The recovery of the method ranged from 97.9 to 103.8% with RSDs that were less than 5.8%. These results demonstrate that this approach has the potential for quality control of A. minor and other Tibetan herbal medicines.

  11. Identification of in vitro and in vivo metabolites of alantolactone by UPLC-TOF-MS/MS.

    PubMed

    Yao, Donggui; Li, Zhe; Huo, Changhong; Wang, Yufang; Wu, Yibing; Zhang, Manli; Li, Ligeng; Shi, Qingwen; Kiyota, Hiromasa; Shi, Xiaowei

    2016-10-15

    Alantolactone (AL), an active sesquiterpene originating from Inula helenium, is a potential anticancer and anti-inflammatory agent. However so far, studies on AL metabolism have not been reported. In the present study, we have investigated for the first time the in vivo and in vitro metabolites of AL using ultra performance liquid chromatography combined with time of flight mass spectrometry (UPLC-TOF-MS/MS). A unique on-line information-dependent acquisition (IDA) method multiple mass defect filter (MMDF) combined with dynamic background subtraction (DBS) was applied to trace all of the probable metabolites of AL. Five MMDF templates were set according to the core structure of AL and the general metabolite biotransformation patterns, and other five sulfur-containing dimer filter templates were first established on the basis of structural elucidation of AL metabolites obtained from rat intestinal bacteria biotransformation. As a result, 44 metabolites were characterized: 41 metabolites from rat urine, bile and feces after oral administration of AL, and 13 metabolites from AL biotransformation by rat intestinal bacteria. Particularly, 26 metabolites were identified as novel sulfur-containing products. The results indicated that addition of double bond at Δ((11,13)) and oxidization were the main metabolic reactions of AL. A new metabolism pathway to produce addition products of H2S to AL and further generate a series of sulfur-containing dimers of AL was revealed. This study significantly enriched our knowledge about AL metabolism, which will lead to a better understanding of the safety and efficacy of AL. At the same time, the established methodology can be widely applied for the structural determination of the metabolites of other sesquiterpene containing α-methylene-γ-lactone moiety.

  12. Methylmalonic acid quantification in low serum volumes by UPLC-MS/MS.

    PubMed

    Pedersen, Theresa L; Keyes, William R; Shahab-Ferdows, Setareh; Allen, Lindsay H; Newman, John W

    2011-06-01

    Methylmalonic acid (MMA) is a metabolic intermediate transformed to succinic acid (SA) by a vitamin B(12)-dependent catalytic step, and is broadly used as a clinical biomarker of functional vitamin B12 status. However, reported methods use between 100 and 1000 μL of serum or plasma making them sub-optimal for sample-limited studies, including those with neonates and infants. LC-MS/MS based protocols to measure MMA as n-butyl esters in the presence of tri-deuterated MMA (MMA-d(3)) were modified for use with 25 μL of human serum by scaling down sample processing volumes and analysis by UPLC-MS/MS. Plasma-based calibration solutions were found to be unnecessary, and chromatographic resolution and peak shape of SA and MMA was optimized in <4 min with isocratic 53:47 methanol/1.67 mM (pH 6.5) ammonium formate. Additionally, 1-cyclohexyl-urido-3-dodecanoic acid (CUDA) was included as internal standard allowing direct assessment of MMA recovery. Sample concentrations in the low normal range produced a signal:noise of >100:1. MMA intra- and inter-assay variability was under 10%. MMA-d(3) surrogate recovery averaged 93±14%. MMA stability exceeded three years in frozen samples and was unaffected by up to five freeze/thaw cycles. In conclusion, we report that methylmalonic acid can be measured with 25 μL of serum using water based standards. The assay signal:noise per concentration indicates that the method could perform as implemented with as little as 5 μL of serum. The reported method is applicable for studies of functional B12 status in sample limited experiments including investigations of nutritional status in neonates and in studies where low normal MMA levels are expected.

  13. [Analysis on component difference in Citrus reticulata before and after being processed with salt by UPLC-Q-TOF/MS].

    PubMed

    Zeng, Rui; Fu, Juan; Wu, La-Bin; Huang, Lin-Fang

    2013-07-01

    To analyze components of Citrus reticulata and salt-processed C. reticulata by ultra-performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry (UPLC-Q-TOF/MS), and compared the changes in components before and after being processed with salt. Principal component analysis (PCA) and partial least squares discriminant analysis (OPLS-DA) were adopted to analyze the difference in fingerprint between crude and processed C. reticulata, showing increased content of eriocitrin, limonin, nomilin and obacunone increase in salt-processed C. reticulata. Potential chemical markers were identified as limonin, obacunone and nomilin, which could be used for distinguishing index components of crude and processed C. reticulata.

  14. Partial least-squares-discriminant analysis differentiating Chinese wolfberries by UPLC-MS and flow injection mass spectrometric (FIMS) fingerprints.

    PubMed

    Lu, Weiying; Jiang, Qianqian; Shi, Haiming; Niu, Yuge; Gao, Boyan; Yu, Liangli Lucy

    2014-09-17

    Lycium barbarum L. fruits (Chinese wolfberries) were differentiated for their cultivation locations and the cultivars by ultraperformance liquid chromatography coupled with mass spectrometry (UPLC-MS) and flow injection mass spectrometric (FIMS) fingerprinting techniques combined with chemometrics analyses. The partial least-squares-discriminant analysis (PLS-DA) was applied to the data projection and supervised learning with validation. The samples formed clusters in the projected data. The prediction accuracies by PLS-DA with bootstrapped Latin partition validation were greater than 90% for all models. The chemical profiles of Chinese wolfberries were also obtained. The differentiation techniques might be utilized for Chinese wolfberry authentication.

  15. Axisymmetric collapses of granular columns

    NASA Astrophysics Data System (ADS)

    Lube, Gert; Huppert, Herbert E.; Sparks, R. Stephen J.; Hallworth, Mark A.

    2004-06-01

    Experimental observations of the collapse of initially vertical columns of small grains are presented. The experiments were performed mainly with dry grains of salt or sand, with some additional experiments using couscous, sugar or rice. Some of the experimental flows were analysed using high-speed video. There are three different flow regimes, dependent on the value of the aspect ratio a {=} h_i/r_i, where h_i and r_i are the initial height and radius of the granular column respectively. The differing forms of flow behaviour are described for each regime. In all cases a central, conically sided region of angle approximately 59(°) , corresponding to an aspect ratio of 1.7, remains undisturbed throughout the motion. The main experimental results for the final extent of the deposit and the time for emplacement are systematically collapsed in a quantitative way independent of any friction coefficients. Along with the kinematic data for the rate of spread of the front of the collapsing column, this is interpreted as indicating that frictional effects between individual grains in the bulk of the moving flow only play a role in the last instant of the flow, as it comes to an abrupt halt. For a {<} 1.7, the measured final runout radius, r_infty, is related to the initial radius by r_infty {=} r_i(1 {+} 1.24a); while for 1.7 {<} a the corresponding relationship is r_infty {=} r_i(1 {+} 1.6a(1/2) ). The time, t_infty, taken for the grains to reach r_infty is given by t_infty {=} 3(h_i/g)(1/2} {=} 3(r_i/g)({1/2}a^{1/2)) , where g is the gravitational acceleration. The insights and conclusions gained from these experiments can be applied to a wide range of industrial and natural flows of concentrated particles. For example, the observation of the rapid deposition of the grains can help explain details of the emplacement of pyroclastic flows resulting from the explosive eruption of volcanoes.

  16. A new, rapid, stability-indicating UPLC method for separation and determination of impurities in amlodipine besylate, valsartan and hydrochlorothiazide in their combined tablet dosage form.

    PubMed

    Vojta, Jiří; Jedlička, Aleš; Coufal, Pavel; Janečková, Lucie

    2015-05-10

    A new rapid stability-indicating UPLC method for separation and determination of impurities in amlodipine besylate, valsartan and hydrochlorothiazide in their combined tablet dosage form was developed. The separation of Ph. Eur. related substances of amlodipine besylate (A, B, D, E, F, G), hydrochlorothiazide (A, B, C), valsartan (B, C), two other valsartan impurities (S)-2-(N-{[2'-cyanobiphenyl-4-yl]methyl}pentanamido)-3-methylbutanoic acid and (S)-3-methyl-2-{[2'-(1H-tetrazol-5-yl)biphenyl-4-yl]methylamino}butanoic acid and several unknown impurities was achieved by reversed phase liquid chromatography with UV detection. The detection wavelengths were set as follows: 225nm for valsartan, its impurities and for the impurity D of amlodipine, 271nm for hydrochlorothiazide and its impurities and 360nm for amlodipine and its impurities except for impurity D. Zorbax Eclipse C8 RRHD (100mm×3.0mm, 1.8μm) was used as a separation column and the analytes were eluted within 11min by a programmed gradient mixture of 0.01M phosphate buffer pH 2.5 and acetonitrile. The method was successfully validated in accordance to the International Conference of Harmonization (ICH) guidelines for amlodipine besylate and its impurity D, valsartan and its impurity C and hydrochlorothiazide and its impurities A, B and C. The triple-combined tablets were exposed to thermal, higher humidity, acid, alkaline, oxidative and photolytic stress conditions. Stressed samples were analyzed by the proposed method. All the significant degradation products and impurities were satisfactory separated from each other and from the principal peaks of drug substances. The peak purity test complied for peaks of amlodipine, valsartan and hydrochlorothiazide in all the stressed samples and indicated no co-elution of degradation products. The method was found to be precise, linear, accurate, sensitive, specific, robust and stability-indicating and could be used as a routine purity test method for amlodipine

  17. Oscillating water column structural model

    SciTech Connect

    Copeland, Guild; Bull, Diana L; Jepsen, Richard Alan; Gordon, Margaret Ellen

    2014-09-01

    An oscillating water column (OWC) wave energy converter is a structure with an opening to the ocean below the free surface, i.e. a structure with a moonpool. Two structural models for a non-axisymmetric terminator design OWC, the Backward Bent Duct Buoy (BBDB) are discussed in this report. The results of this structural model design study are intended to inform experiments and modeling underway in support of the U.S. Department of Energy (DOE) initiated Reference Model Project (RMP). A detailed design developed by Re Vision Consulting used stiffeners and girders to stabilize the structure against the hydrostatic loads experienced by a BBDB device. Additional support plates were added to this structure to account for loads arising from the mooring line attachment points. A simplified structure was designed in a modular fashion. This simplified design allows easy alterations to the buoyancy chambers and uncomplicated analysis of resulting changes in buoyancy.

  18. Development and validation of an UPLC-MS/MS method for the quantification of irinotecan, SN-38 and SN-38 glucuronide in plasma, urine, feces, liver and kidney: Application to a pharmacokinetic study of irinotecan in rats.

    PubMed

    Basu, Sumit; Zeng, Min; Yin, Taijun; Gao, Song; Hu, Ming

    2016-03-15

    The objective of this research is to develop and validate a sensitive and reproducible UPLC-MS/MS method to quantify irinotecan, its active metabolite SN-38 and SN-38 glucuronide (phase II metabolite of SN-38) simultaneously in different bio-matrices (plasma, urine, feces), tissues (liver and kidney) and to use the method to investigate its pharmacokinetic behavior in rats. Irinotecan, SN-38 and SN-38 glucuronide has been resolved and separated by C18 column using acetonitrile and 0.1% formic acid in water used as the mobile phases. Triple quadruple mass spectrometer using multiple reaction monitoring (MRM) with positive scan mode were employed to perform mass analysis. The results showed that the linear response range of irinotecan and SN-38 in plasma, feces, liver and kidney is 4.88-10000 nM, 39-5000 nM, 48.8-6250 nM and 48.8-6250 nM, respectively (R(2)>0.99). In case of SN-38 glucuronide, the standard curves were linear in the concentration range of 6.25-2000 nM, 4.88-1250 nM, 9.8-1250 nM and 9.8-1250 nM in plasma, feces, liver and kidney homogenates, respectively. The lower limit of detection (LLOD) of irinotecan, SN-38 and SN-38 glucuronide was determined to be less than 25 nM in all bio-matrices as well as tissue homogenates. Recoveries of irinotecan, SN-38 and SN-38 glucuronide at three different concentrations (low, medium and high) were not less than 85% at three different concentrations in plasma and feces. The percentage matrix factors in different bio-matrices and tissues were within 20%. The UPLC-MS/MS method was validated with intra-day and inter-day precision of less than 15% in plasma, feces, liver and kidney. Owing to the high sensitivity of this method, only 20 μl of plasma, urine and homogenates of liver, kidney and feces is needed. The validated method has been successfully employed for pharmacokinetic evaluation of irinotecan in male wistar rats to quantify irinotecan, SN-38 and SN-38 glucuronide in plasma, feces, and urine samples.

  19. Simultaneous determination of bioactive components of Radix Angelicae Sinensis-Radix Paeoniae Alba herb couple in rat plasma and tissues by UPLC-MS/MS and its application to pharmacokinetics and tissue distribution.

    PubMed

    Luo, Niancui; Li, Zhenhao; Qian, Dawei; Qian, Yefei; Guo, Jianming; Duan, Jin-Ao; Zhu, Min

    2014-07-15

    A highly sensitive and rapid ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed and validated for simultaneous quantification of seven components in rat plasma and five components in rat tissues after oral administration of the extracts of different combination Radix Angelicae Sinensis-Radix Paeoniae Alba herb couple and has been applied to compare the different pharmacokinetics and tissue distribution properties of these bioactive components. The extracts of Radix Angelicae Sinensis (RAS), Radix Paeoniae Alba (RPA) and Radix Angelicae Sinensis-Radix Paeoniae Alba herb couple (RRHC) were orally administrated to rats, respectively. The concentrations of ferulic acid, caffeic acid, vanillic acid, ligustilide, paeoniflorin, albiflorin and oxypaeoniflorin in rat plasma and the concentrations of ferulic acid, vanillic acid, paeoniflorin, albiflorin and oxypaeoniflorin in tissues were determined by UPLC-MS/MS. The plasma samples were pretreated by protein precipitation with methanol and the tissue samples were homogenated with water and pretreated by protein precipitation with methanol. Chromatographic separation was performed on a C18 column using 0.1% formic acid-acetonitrile as mobile phase for gradient elution. A triple quadrupole (TQ) tandem mass spectrometry equipped with an electrospray ionization source was used as detector operating both in positive and negative ionization mode and operated by multiple-reaction monitoring (MRM) scanning. Noncompartmental pharmacokinetic parameters were calculated by DAS 2.0 program. The differences between each group were compared by SPSS 16.0 with Independent-Samples T-test. The pharmacokinetic parameters (such as Cmax, Tmax, T1/2, AUC0-T, MRT0-T, Vz/F or CLz/F) of all the detected components between the single herb (RAS or RPA) and herb pair (RRHP) showed significant differences (P<0.05). It indicated that the compatibility of RAS and RPA could alter the pharmacokinetics features

  20. Stage-frit: A straightforward sub-2 μm nano-liquid chromatography column fabrication for proteomic analysis.

    PubMed

    Hsieh, Ming-Yueh; Hsiao, He-Hsuan

    2015-07-30

    In this work we demonstrated a facile method for the fabrication of C18 coordination polymer gel in a capillary, called stage-frit, which was efficiently applied to pack sub-2 μm C18 beads into the capillary by a high pressure bomb for the online separation of proteolytic peptides. The back pressure of the column with 10 cm × 75 μm i.d. is regularly lower than 170 bar at a flow rate of 300 nl/min, which could be operated on a common nanoLC system instead of nanoUPLC system due to the good permeability, low back pressure and high mechanical stress of the frit that will totally reduce the cost for the purchase of instrument. The stage-frit allows long-term continuous flow of the solvent and no significant beads loss or pressure instability was observed during the period. The repeatability of retention time for fifteen BSA tryptic peaks was found to be less than 1.08% (RSD) in six time nanoLC-ESI-MS/MS experiments. The average full width at half maximum (FWHM) of peptide peaks is 5.87 s. The sub-2 μm stage-frit nanoLC column showed better sensitivity than the commercial available for large scale proteomic analysis of total tissue proteins from human spleen. The number of identified peptides is approximately 0.4-fold and 0.2-fold higher than that obtained by utilizing commercial columns packed with 3 μm and 1.8 μm C18 materials, respectively. In the field of analytical chemistry, particularly the use of nanoLC systems, stage-frit nanoLC column offers a great potential for the separation of complex mixtures.

  1. The jet flotation column control system

    SciTech Connect

    Xu Zhiqiang; Ming Shangzhi; Liu Lijian; Huangfu Jinghua; Huo Sen; Zhang Rongzeng; Yang Hongjun

    1998-12-31

    Compared with the conventional mechanical flotation column, the jet flotation column has the advantages of high selectivity of separation, low investment and production cost, low floor space requirement, low dosage of reagent, easy control; it is more suitable to process fine particles. Recently, many new types of flotation columns have been developed with new methods. Mineral Processing Dept., China University of Mining and Technology (Beijing) designed an aerated, double-jet flotation column in the lab and the industrial trial will be put into operation. One of the significant characteristics of the new type of flotation column is high selectivity of separation, fast bubble mineralization speed. As it is sensitive to various factors, a control system for flotation column has been developed to stabilize the working condition, and this set of control system has been operated in the lab experiment.

  2. REDISTRIBUTOR FOR LIQUID-LIQUID EXTRACTION COLUMNS

    DOEpatents

    Bradley, J.G.

    1957-10-29

    An improved baffle plate construction to intimately mix immiscible liquid solvents for solvent extraction processes in a liquid-liquid pulse column is described. To prevent the light and heavy liquids from forming separate continuous homogeneous vertical channels through sections of the column, a baffle having radially placed rectangular louvers with deflection plates opening upon alternate sides of the baffle is placed in the column, normal to the axis. This improvement substantially completely reduces strippiig losses due to poor mixing.

  3. Soil column leaching of pesticides.

    PubMed

    Katagi, Toshiyuki

    2013-01-01

    In this review, I address the practical and theoretical aspects of pesticide soil mobility.I also address the methods used to measure mobility, and the factors that influence it, and I summarize the data that have been published on the column leaching of pesticides.Pesticides that enter the unsaturated soil profile are transported downwards by the water flux, and are adsorbed, desorbed, and/or degraded as they pass through the soil. The rate of passage of a pesticide through the soil depends on the properties of the pesticide, the properties of the soil and the prevailing environmental conditions.Because large amounts of many different pesticides are used around the world, they and their degradates may sometimes contaminate groundwater at unacceptable levels.It is for this reason that assessing the transport behavior and soil mobility of pesticides before they are sold into commerce is important and is one indispensable element that regulators use to assess probable pesticide safety. Both elementary soil column leaching and sophisticated outdoor lysimeter studies are performed to measure the leaching potential for pesticides; the latter approach more reliably reflects probable field behavior, but the former is useful to initially profile a pesticide for soil mobility potential.Soil is physically heterogeneous. The structure of soil varies both vertically and laterally, and this variability affects the complex flow of water through the soil profile, making it difficult to predict with accuracy. In addition, macropores exist in soils and further add to the complexity of how water flow occurs. The degree to which soil is tilled, the density of vegetation on the surface, and the type and amounts of organic soil amendments that are added to soil further affect the movement rate of water through soil, the character of soil adsorption sites and the microbial populations that exist in the soil. Parameters that most influence the rate of pesticide mobility in soil are

  4. Coumarin and furanocoumarin quantitation in citrus peel via ultraperformance liquid chromatography coupled with mass spectrometry (UPLC-MS).

    PubMed

    Dugrand, Audray; Olry, Alexandre; Duval, Thibault; Hehn, Alain; Froelicher, Yann; Bourgaud, Frédéric

    2013-11-13

    Coumarins and furanocoumarins are secondary metabolites commonly found in citrus plants. These molecules are allelochemical compounds in plants that have controversial effects on humans, such as phototoxicity and the commonly described interactions with drugs, referred to as the "grapefruit juice effect". Thus, it is important to develop a reliable method to identify and quantitate the coumarins and furanocoumarins in citrus extracts. For this purpose, we herein describe an ultraperformance liquid chromatography coupled with mass spectrometry (UPLC-MS)-based method. We first developed a rapid UPLC method (20 min) to separate the isomers of each furanocoumarin. A subsequent single ion monitoring MS detection method was performed to distinguish between the molecules, which were possibly coeluting but had different molecular weights. The method was successfully used to separate and quantitate 6 coumarins and 21 furanocoumarins in variable amounts within peel extracts (flavedo and albedo) of 6 varieties of Citrus (sweet orange, lemon, grapefruit, bergamot, pummelo, and clementine). This method combines high selectivity and sensitivity in a rapid analysis and is useful for fingerprinting Citrus species via their coumarin and furanocoumarin contents.

  5. Metabolome classification of commercial Hypericum perforatum (St. John's Wort) preparations via UPLC-qTOF-MS and chemometrics.

    PubMed

    Farag, Mohamed A; Wessjohann, Ludger A

    2012-03-01

    The growing interest in the efficacy of phytomedicines and herbal supplements but also the increase in legal requirements for safety and reliable contents of active principles drive the development of analytical methods for the quality control of complex, multicomponent mixtures as found in plant extracts of value for the pharmaceutical industry. Here, we describe an ultra-performance liquid chromatography method (UPLC) coupled with quadrupole time of flight mass spectrometry (qTOF-MS) measurements for the large scale analysis of H. perforatum plant material and its commercial preparations. Under optimized conditions, we were able to simultaneously quantify and identify 21 metabolites including 4 hyperforins, 3 catechins, 3 naphthodianthrones, 5 flavonoids, 3 fatty acids, and a phenolic acid. Principal component analysis (PCA) was used to ensure good analytical rigorousness and define both similarities and differences among Hypericum samples. A selection of batches from 9 commercially available H. perforatum products available on the German and Egyptian markets showed variable quality, particularly in hyperforins and fatty acid content. PCA analysis was able to discriminate between various preparations according to their global composition, including differentiation between various batches from the same supplier. To the best of our knowledge, this study provides the first approach utilizing UPLC-MS-based metabolic fingerprinting to reveal secondary metabolite compositional differences in Hypericum extract.

  6. Varietal classification and antioxidant activity prediction of Osmanthus fragrans Lour. flowers using UPLC-PDA/QTOF-MS and multivariable analysis.

    PubMed

    Zhou, Fei; Peng, Jiyu; Zhao, Yajing; Huang, Weisu; Jiang, Yirong; Li, Maiquan; Wu, Xiaodan; Lu, Baiyi

    2017-02-15

    This study was aimed to classify the varieties and predict the antioxidant activity of Osmanthus fragrans flowers by UPLC-PDA/QTOF-MS and multivariable analysis. The PLS-DA model successfully classified the four varieties based on both the 21 identified compounds and the effective compounds. For the antioxidant activity prediction, PLS performed well to predict the antioxidant activity of O. fragrans flowers. Furthermore, acteoside, suspensaside A, ligustroside, forsythoside A, phillygenin and caffeic acid were selected as effective compounds by UVE-SPA for prediction. On the basis of effective compounds, PLS, MLR and PCR were applied to establish the calibration models. The UVE-SPA-MLR model was the optimal method to predict the antioxidant activity values with Rp of 0.9200, 0.9010 and 0.8905 for DPPH, ABTS and FRAP assays, respectively. The results revealed that the UPLC-PDA/QTOF-MS combined with chemometrics could be a new method to classify the varieties and predict the antioxidant activity of O. fragrans flowers.

  7. Secondary metabolite profiling of Curcuma species grown at different locations using GC/TOF and UPLC/Q-TOF MS.

    PubMed

    Lee, Jueun; Jung, Youngae; Shin, Jeoung-Hwa; Kim, Ho Kyoung; Moon, Byeong Cheol; Ryu, Do Hyun; Hwang, Geum-Sook

    2014-07-04

    Curcuma, a genus of rhizomatous herbaceous species, has been used as a spice, traditional medicine, and natural dye. In this study, the metabolite profile of Curcuma extracts was determined using gas chromatography-time of flight mass spectrometry (GC/TOF MS) and ultrahigh-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC/Q-TOF MS) to characterize differences between Curcuma aromatica and Curcuma longa grown on the Jeju-do or Jin-do islands, South Korea. Previous studies have performed primary metabolite profiling of Curcuma species grown in different regions using NMR-based metabolomics. This study focused on profiling of secondary metabolites from the hexane extract of Curcuma species. Principal component analysis (PCA) and partial least-squares discriminant analysis (PLS-DA) plots showed significant differences between the C. aromatica and C. longa metabolite profiles, whereas geographical location had little effect. A t-test was performed to identify statistically significant metabolites, such as terpenoids. Additionally, targeted profiling using UPLC/Q-TOF MS showed that the concentration of curcuminoids differed depending on the plant origin. Based on these results, a combination of GC- and LC-MS allowed us to analyze curcuminoids and terpenoids, the typical bioactive compounds of Curcuma, which can be used to discriminate Curcuma samples according to species or geographical origin.

  8. Programmable selectivity for GC with series-coupled columns using pulsed heating of the second column.

    PubMed

    Whiting, Joshua; Sacks, Richard

    2003-05-15

    A series-coupled ensemble of a nonpolar dimethyl polysiloxane column and a polar trifluoropropylmethyl polysiloxane column with independent at-column heating is used to obtain pulsed heating of the second column. For mixture component bands that are separated by the first column but coelute from the column ensemble, a temperature pulse is initiated after the first of the two components has crossed the column junction point and is in the second column, while the other component is still in the first column. This accelerates the band for the first component. If the second column cools sufficiently prior to the second component band crossing the junction, the second band experiences less acceleration, and increased separation is observed for the corresponding peaks in the ensemble chromatogram. High-speed at-column heating is obtained by wrapping the fused-silica capillary column with resistance heater wire and sensor wire. Rapid heating for a temperature pulse is obtained with a short-duration linear heating ramp of 1000 degrees C/min. During a pulse, the second-column temperature increases by 20-100 degrees C in a few seconds. Using a cold gas environment, cooling to a quiescent temperature of 30 degrees C can be obtained in approximately 25 s. The effects of temperature pulse initiation time and amplitude on ensemble peak separation and resolution are described. A series of appropriately timed temperature pulses is used to separate three coeluting pairs of components in a 13-component mixture.

  9. Effect of column dimension on observed column efficiency in very high pressure liquid chromatography.

    PubMed

    Wu, Naijun; Bradley, Ashley C

    2012-10-26

    The effect of extra-column volume on observed linear velocity was investigated for columns of various internal diameters in very high pressure liquid chromatography. The results showed that the observed linear velocities were approximately 4.5, 9.5, 16.8, and 39.5% lower than the linear velocities corrected for the extra-column volume contribution for 4.6, 3.0, 2.1, and 1.0mm internal diameter columns, respectively. An empirical relationship between extra-column band broadening and extra-column volume was obtained using 50 cm long tubings of various internal diameters. The peak variance from the extra-column volume is near linearly proportional to the square of the extra-column volume for tubings with 0.0635-0.178 mm (0.025-0.07 in.) i.d. using a 50/50 acetonitrile/water mobile phase at flow rates greater than 0.3 mL/min. The effect of column internal diameter and column length on observed efficiency was studied using 50mm columns with four different column internal diameters and 2.1mm i.d columns with three different lengths. The results showed that the observed column efficiencies for 3.0, 2.1, and 1.0mm internal diameter columns were 18, 33, and 73% lower than that for a 4.6mm internal diameter column for benzophenone (k=5.5), respectively. An approximate 20% decrease in theoretical plate number was observed for propiophenone (k=3.3) using a 50 mm × 2.1 mm column packed with 1.7 μm particles compared to a 150 mm × 2.1 mm column packed with 5.0 μm particles, while the former column provided 9 fold faster separation. It is the column to extra column volume ratio instead of absolute extra-column volume that determines the degree of extra-column band-broadening in VHPLC.

  10. Synthesis of Ion Microbeam Column

    NASA Astrophysics Data System (ADS)

    Mui, Peter Hon-Fung

    1995-01-01

    Electrostatic lenses have traditionally been designed by analyzing and combining different electrode configurations. Computational complexity typically limits such systems to a few geometrically simple elements, where the component interactions are neglected and not exploited to combat the various aberrations. Recently, Szilagyi and Szep have demonstrated that an axially symmetric column of circular plates, with the electrode potentials optimized for focusing, can surpass the typical conventional designs by many times in performance. Following the footsteps of pioneers like Burfoot and Hawkes, we partition the plates in order to transcend the limitations set by Scherzer's theorem on the chromatic and spherical aberrations of axially symmetric structures. Two algorithms, one based upon integral asymptotics and one upon the Levinson algorithm. for Toeplitz matrix inversion, are developed to complement the charge-density method in analyzing the new column structures. Various optimization schemes are combined to avoid shallow minima at a reasonable computational cost. With each plate partitioned into four sectors, we show that the interactions between the monopole and the quadrupole components can increase the output current density by more than 400% over the axially symmetric structure. By adjusting the sector potentials, we can realize systems capable of both focusing and deflecting the beam. In comparison to some existing designs, our systems excel in both performance and compactness, sometimes by many hundred percents. We then further partition the plates to generate the "octupole" deflectors and correctors. We show that the "octupole" deflectors can drastically slow down the beam degradation with deflection distance and that the correctors can further increase the output current density by more than 300%. Finally, we apply linear system theories to the study of the first-order properties of optical systems with different symmetries. We showed, without resorting to

  11. Assessment of cosmetic ingredients in the in vitro reconstructed human epidermis test method EpiSkin™ using HPLC/UPLC-spectrophotometry in the MTT-reduction assay.

    PubMed

    Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P

    2016-06-01

    Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods.

  12. Simultaneous determination of the absolute configuration of twelve monosaccharide enantiomers from natural products in a single injection by UPLC-UV/MS method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In natural product chemistry, it is often crucial to determine sugar composition as well as the absolute configuration of each monosaccharide in glycosides. An ultra-performance liquid chromatography method using both photodiode array (PDA) and mass spectrometry detectors (UPLC-UV/MS) was developed....

  13. Development of an UPLC-MS/MS Sulfonamide Multi-residue Method and It's Application to Water, Manure Slurry, and Soils from Swine Rearing Facilities

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrophotometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. The instrumental detection limit based on signal-to-noise ratio (S/N) > 3, was below 1 pg/µL...

  14. Quantitative determination of curcuminoids from the Roots of Curcuma longa, Curcuma species and dietary supplements using an UPLC-UV-MS method

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A simple, fast UPLC-UV-MS method was developed for the determination of curcuminoids from roots of Curcuma longa L., Curcuma species (C. zedoaria, C. phaecaulis, C. wenyujin and C. kwangsiensis) and dietary supplements claiming to contain C. longa. The total content of curcuminoids (curcumin, desmet...

  15. Simultaneous determination of alkaloids and flavonoids from aerial parts of Passiflora species and dietary supplements using UPLC-UV-MS and HPTLC

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A rapid UPLC method was developed for the simultaneous analysis of five indole alkaloids (harmalol, harmol, harmane, harmaline and harmine) and four flavonoids (orientin, isoorientin, vitexin, and isovitexin) from the aerial parts of Passiflora incarnata L. (Passifloracea), different species of Pass...

  16. Rapid qualitative and quantitative analysis of proanthocyanidin oligomers and polymers by ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...

  17. Qualitative and quantitative analysis of major constituents from Dazhu Hongjingtian capsule by UPLC/Q-TOF-MS/MS combined with UPLC/QQQ-MS/MS.

    PubMed

    Liu, Guang-Da; Zhao, Yi-Wu; Li, Yan-Jing; Wang, Xue-Jing; Si, Hai-Hong; Huang, Wen-Zhe; Wang, Zhen-Zhong; Ma, Shi-Ping; Xiao, Wei

    2016-11-09

    In this work, a sensitive and efficient method was established and validated for qualitative and quantitative analysis of major bioactive constituents in Dazhu Hongjingtian capsule by liquid chromatography tandem mass spectrometry. A total of 32 compounds were tentatively identified using ultra-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry. Furthermore, 12 constituents, namely gallic acid, 3,4-dihydroxybenzoic acid, salidroside, p-coumaric acid-4-O-β-d-glucopyranoside, bergeninum, 4-hydroxybenzoic acid, 4-hydroxyphenylacetic acid, syringate, 6''-O-galloylsalidroside, rhodiosin, rhodionin and kaempferol-7-O-α-l-rhamnoside, were simultaneously quantified by the developed ultra-performance liquid chromatography coupled with a triple quadrupole mass spectrometry method in 9 min. All of them were analyzed on an Agilent ZorBax SB-C18 column (3.0 × 100 mm, 1.8 μm) with linear gradient elution of methanol-0.1% formic acid water. The proposed method was applied to analyze three batches of samples with acceptable linearity (R, 0.9979-0.9997), precision (RSD, 1.3-4.7%), repeatability (RSD, 1.7-4.9%), stability (RSD, 2.2-4.9%) and recovery (RSD, 0.6-4.4%) of the 12 compounds. As a result, the analytical method possessing high throughput and sensitivity is suitable for the quality control of Dazhu Hongjingtian capsule.

  18. Circulation in gas-slurry column reactors

    SciTech Connect

    Clark, N.; Kuhlman, J.; Celik, I.; Gross, R.; Nebiolo, E.; Wang, Yi-Zun.

    1990-08-15

    Circulation in bubble columns, such as those used in fischer-tropsch synthesis, detracts from their performance in that gas is carried on average more rapidly through the column, and the residence time distribution of the gas in the column is widened. Both of these factors influence mass-transfer operations in bubble columns. Circulation prediction and measurement has been undertaken using probes, one-dimensional models, laser Doppler velocimetry, and numerical modeling. Local void fraction was measured using resistance probes and a newly developed approach to determining air/water threshold voltage for the probe. A tall column of eight inch diameter was constructed of Plexiglas and the distributor plate was manufactured to distribute air evenly through the base of the column. Data were gathered throughout the volume at three different gas throughputs. Bubble velocities proved difficult to measure using twin probes with cross-correlation because of radial bubble movement. A series of three-dimensional mean and RMS bubble and liquid velocity measurements were also obtained for a turbulent flow in a laboratory model of a bubble column. These measurements have been made using a three-component laser Doppler velocimeter (LDV), to determine velocity distributions non-intrusively. Finally, the gas-liquid flow inside a vertically situated circular isothermal column reactor was simulated numerically. 74 refs., 170 figs., 5 tabs.

  19. 29 CFR 1926.755 - Column anchorage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Steel Erection § 1926.755 Column anchorage. (a... field-modified without the approval of the project structural engineer of record. (2) Prior to the erection of a column, the controlling contractor shall provide written notification to the steel erector...

  20. Maintenance of column performance at scale.

    PubMed

    William, Alan; Taylor, Kathy; Dambuleff, Kyril; Persson, Owe; Kennedy, Robert M

    2002-01-25

    Pack-in-place column packing methods were developed for Q Sepharose Big Beads at 40 cm I.D. and scaled up to 200 cm I.D. in Chromaflow columns. The efficiency and asymmetry of the packed bed were evaluated as a function of test velocity and sample volume. The performance of the packed beds at both scales approached the theoretical limits of column performance (Hred =2 and Af=1) expected in small analytical columns. The packing strategy was effective for scale up and the stability of the packed beds, the effectiveness of the column design with respect to the mobile phase distribution system and the stability of the media to the pack-in-place technology, are presented.

  1. Newborn screening for galactosemia by a second-tier multiplex enzyme assay using UPLC-MS/MS in dried blood spots.

    PubMed

    Ko, Dae-Hyun; Jun, Sun-Hee; Park, Kyoung Un; Song, Sang Hoon; Kim, Jin Q; Song, Junghan

    2011-04-01

    Galactosemia is one of the most important inherited metabolic disorders detected by newborn screening tests. Abnormal results during screening should be confirmed by enzyme activity assays. Recently, we developed a multiplex enzyme assay for galactosemia in erythrocytes using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). In this study, we proposed a second-tier multiplex enzyme assay for galactosemia that can be directly applied to dried blood spots (DBSs). Supernatants from two rehydrated-punched 3.2-mm DBSs were incubated with a reaction mixture containing [¹³C6]galactose, [¹³C2]galactose-1-phosphate, and UDP-glucose as substrates for three galactose-metabolizing enzymes. After a 4-hour incubation, the end products from the combined reaction mixture, [¹³C6]galactose-1-phosphate, UDP-[¹³C2]galactose, and UDP-galactose, were simultaneously measured using UPLC-MS/MS. Substrates, products, and internal standards from the mixture of the three enzyme reactions were clearly separated in the UPLC-MS/MS system, with an injection cycle time of 10 min. Intra- and inter-assay imprecisions of the UPLC-MS/MS were 8.4-14.8% and 13.2-15.7% CV, respectively. Enzyme activities in DBSs from 37 normal individuals and 10 patients with enzyme deficiencies were analyzed. DBSs from galactosemia patients showed consistently lower enzyme activities as compared to those of normal individuals. In conclusion, multiplex enzyme assays using UPLC-MS/MS can be successfully applied to DBS analysis. This method allows a fast and effective second-tier test for newborns showing abnormal screening results.

  2. Chlorpromazine quantification in human plasma by UPLC-electrospray ionization tandem mass spectrometry. Application to a comparative pharmacokinetic study.

    PubMed

    Borges, Ney Carter; Rezende, Vinicius Marcondes; Santana, Jose Marcos; Moreira, Ricardo Pereira; Moreira, Roberto Fernandes; Moreno, Patrícia; Borges, Diego Carter; Donato, José Luiz; Moreno, Ronilson Agnaldo

    2011-12-01

    In the present study a method to quantify chlorpromazine in human plasma using cyclobenzaprine as the internal standard (IS) is described. The analyte and the IS were extracted from human plasma by a liquid-liquid extraction with diethyl ether/dichloromethane (70/30, v/v) and analyzed by an ultra performance liquid chromatography (UPLC) coupled to an electrospray tandem triple quadrupole mass spectrometer in positive mode (UPLC-ES(+)-MS/MS). Chromatography was performed isocratically on an Aquity UPLC BEH C18 1.7 μm (50 mm × 2.1 mm i.d.) operating at 40°C. The mobile phase was a mixture of 65% water+1% formic acid and 35% of acetonitrile at a flow-rate of 0.5 mL/min. The lowest concentration quantified was 0.5 ng/mL and a linear calibration curve over the range 0.5-200 ng/mL was obtained, showing intra-assay precisions from 2.4 to 5.8%, and inter-assay precisions from 3.6 to 9.9%. The intra-assay accuracies ranged from 96.9 to 102.5%, while the inter-assay accuracies ranged from 94.1 to 100.3%. This analytical method was applied in a relative bioavailability study in order to compare a test chlorpromazine 100 mg simple dose formulation versus a reference in 57 volunteers of both sexes. The study was conducted in an open randomized two-period crossover design and with a fourteen days washout period. Plasma samples were obtained over a 144-h interval. Since the 90% CI for both C(max), AUC(last) and AUC(0-inf) were within the 80-125% interval proposed by the Food and Drug Administration and ANVISA, it was concluded that chlorpromazine 100 mg/dose was bioequivalent to the reference formulation, according to both the rate and extent of absorption.

  3. On-line coupling of macroporous resin column chromatography with direct analysis in real time mass spectrometry utilizing a surface flowing mode sample holder.

    PubMed

    Zeng, Shanshan; Wang, Lu; Chen, Teng; Qu, Haibin

    2014-02-06

    A surface flowing mode sample holder was designed as an alternative sampling strategy for direct analysis in real time mass spectrometry (DART-MS). With the sample holder, the on-line coupling of macroporous resin column chromatography with DART-MS was explored and the new system was employed to monitor the column chromatography elution process of Panax notoginseng. The effluent from macroporous resin column was first diluted and mixed with a derivatization reagent on-line, and the mixture was then directly transferred into the ionization region of DART-MS by the sample holder. Notoginsenosides were methylated and ionized in a metastable helium gas stream, and was introduced into MS for detection. The on-line system showed reasonable repeatability with a relative standard deviation of 12.3% for the peak area. Three notoginsenosides, i.e. notoginsenoside R1, ginsenoside Rb1 and ginsenoside Rg1, were simultaneously determined during the eluting process. The alteration of the chemical composition in the effluent was accurately identified in 9 min, agreeing well with the off-line analysis. The presented technique is more convenient compared to the traditional UPLC method. These results suggest that the surface flowing mode DART-MS has a good potential for the on-line process monitoring in the pharmaceutical industry.

  4. Determination of multicomponent contents in Calculus bovis by ultra-performance liquid chromatography-evaporative light scattering detection and its application for quality control.

    PubMed

    Kong, Weijun; Jin, Cheng; Xiao, Xiaohe; Zhao, Yanling; Liu, Wei; Li, Zulun; Zhang, Ping

    2010-06-01

    A fast ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) method was established for simultaneous quantification of seven components in natural Calculus bovis (C. bovis) and its substitutes or spurious breeds. On a Waters Acquity UPLC BEH C(18) column, seven analytes were efficiently separated using 0.2% aqueous formic acid-acetonitrile as the mobile phase in a gradient program. The evaporator tube temperature of ELSD was set at 100 degrees C with the nebulizing gas flow-rate of 1.9 L/min. The results showed that this established UPLC-ELSD method was validated to be sensitive, precise and accurate with the LODs of seven analytes at 2-11 ng, and the overall intra-day and inter-day variations less than 3.0%. The recovery of the method was in the range of 97.8-101.6%, with RSD less than 3.0%. Further results of PCA on the contents of seven investigated analytes suggested that compounds of cholic acid, deoxycholic acid and chenodeoxycholic acid or cholesterol should be added as chemical markers to UPLC analysis of C. bovis samples for quality control and to discriminate natural C. bovis sample and its substitutes or some spurious breeds, then normalize the use of natural C. bovis and ensure its clinical efficacy.

  5. Analysis of steroidal alkaloids and saponins in Solanaceae plant extracts using UPLC-qTOF mass spectrometry.

    PubMed

    Heinig, Uwe; Aharoni, Asaph

    2014-01-01

    Plants of the Solanaceae family are renowned for the production of cholesterol-derived steroidal glycosides, including the nitrogen containing glycoalkaloids and steroidal saponins. In this chapter we describe the use of UPLC (Ultra Performance Liquid Chromatography) coupled with qTOF (Quadrupole Time-of-Flight) mass spectrometry for profiling of these two large classes of semipolar metabolites. The presented method includes an optimized sample preparation protocol, a procedure for high resolution chromatographic separation and metabolite detection using the TOF mass spectrometer which provides high resolution and mass accuracy. A detailed description for non-targeted data analysis and a strategy for putative identification of steroidal glycosides from complex extracts based on interpretation of mass fragmentation patterns is also provided. The described methodology allows profiling and putative identification of multiple steroidal glycoside compounds from the assortment of Solanaceae species producing these molecules.

  6. Phenylethanoid Glycoside Profiles and Antioxidant Activities of Osmanthus fragrans Lour. Flowers by UPLC/PDA/MS and Simulated Digestion Model.

    PubMed

    Jiang, Yirong; Mao, Shuqin; Huang, Weisu; Lu, Baiyi; Cai, Zengxuan; Zhou, Fei; Li, Maiquan; Lou, Tiantian; Zhao, Yajing

    2016-03-30

    Variations of phenylethanoid glycoside profiles and antioxidant activities in Osmanthus fragrans flowers through the digestive tract were evaluated by a simulated digestion model and UPLC/PDA/MS. Major phenylethanoid glycosides and phenolic acids, namely, salidroside, acteoside, isoacteoside, chlorogenic acid, and caffeic acid, were identified in four cultivars of O. fragrans flowers, and the concentration of acteoside was the highest, being up to 71.79 mg/g dry weight. After simulated digestion, total phenylethanoid glycoside contents and antioxidant activities were significantly decreased. Acteoside was identified as decomposing into caffeic acid, whereas salidroside was found to be stable during simulated digestion. According to Pearson's correlation analysis, acteoside contents showed good correlations with antioxidant activities during simulated digestion (R(2) = 0.994, P < 0.01). In conclusion, acteoside was the major contributor to the antioxidant activity of O. fragrans flowers, and salidroside was considered as the major antioxidant compound of O. fragrans flowers in vivo.

  7. Lipidomics profiling of goat milk, soymilk and bovine milk by UPLC-Q-Exactive Orbitrap Mass Spectrometry.

    PubMed

    Li, Qiangqiang; Zhao, Yan; Zhu, Dan; Pang, Xiumei; Liu, Yue; Frew, Russell; Chen, Gang

    2017-06-01

    Lipids are very important for human health and milk is a rich dietary source of lipids. In this study, the lipid content in three types of milk (goat, soy and bovine) were determined by using UPLC-Q-Exactive Orbitrap Mass Spectrometry. A total of 13 classes of lipids (including Cer, SM, LPC, PC, PE, DG, TG, PA, PG, PI, PS, LPE, FA) were measured. Moreover, lipid profiles differed significantly between the different milk types. Soymilk is rich in phospholipids including PC, PE, PS, PG, while goat milk is rich in medium chain triglycerides (MCT), USFA, ω-6 FA and ω-3 FA, especially EPA and DHA. Furthermore, a PLS model was established for differentiation of milk types based on the lipid profiles. A total of 14 lipids were identified as biomarkers for differentiation of milk types, thus providing a basis for milk authentication and detection of adulteration.

  8. Detection and expression analysis of recombinant proteins in plant-derived complex mixtures using nanoUPLC-MS(E).

    PubMed

    Murad, André M; Souza, Gustavo H M F; Garcia, Jerusa S; Rech, Elíbio L

    2011-10-01

    The use of mass spectrometry to identify recombinant proteins that are expressed in total soluble proteins (TSPs) from plant extracts is necessary to accelerate further processing steps. For example, the method consists of TSP sample preparation and trypsin digestion prior to the preliminary characterization using nanoUPLC-MS(E) analysis of the recombinant proteins that are expressed in TSP samples of transgenic soybean seeds. A TSP sample as small as 50 μg can be effectively analyzed. In this study, transgenic soybean seeds that expressed recombinant cancer testis antigen (CTAG) were used. The procedure covered 30% of the protein sequence and was quantified at 0.26 ng, which corresponded to 0.1% of the TSP sample. A comparative proteomic profile was generated by the comparison of a negative control and sample that showed a unique expression pattern of CTAG in a transgenic line. The experimental data from the TSP extraction, sample preparation and data analysis are discussed herein.

  9. Differentiating Milk and Non-milk Proteins by UPLC Amino Acid Fingerprints Combined with Chemometric Data Analysis Techniques.

    PubMed

    Lu, Weiying; Lv, Xiaxia; Gao, Boyan; Shi, Haiming; Yu, Liangli Lucy

    2015-04-22

    Amino acid fingerprinting combined with chemometric data analysis was used to differentiate milk and non-milk proteins in this study. Microwave-assisted hydrolysis and ultraperformance liquid chromatography (UPLC) were used to obtain the amino acid fingerprints. Both univariate and multivariate chemometrics methods were applied for differentiation. The confidence boundary of amino acid concentration, principal component analysis (PCA), and partial least-squares-discriminant analysis (PLS-DA) of the amino acid fingerprints demonstrated that there were significant differences between milk proteins and inexpensive non-milk protein powders from other biological sources including whey, peanut, corn, soy, fish, egg yolk, beef extract, collagen, and cattle bone. The results indicate that the amino acid compositions with the chemometric techniques could be applied for the detection of potential protein adulterants in milk.

  10. An improved UPLC method for the detection of undeclared horse meat addition by using myoglobin as molecular marker.

    PubMed

    Di Giuseppe, Antonella M A; Giarretta, Nicola; Lippert, Martina; Severino, Valeria; Di Maro, Antimo

    2015-02-15

    In 2013, following the scandal of the presence of undeclared horse meat in various processed beef products across the Europe, several researches have been undertaken for the safety of consumer health. In this framework, an improved UPLC separation method has been developed to detect the presence of horse myoglobin in raw meat samples. The separation of both horse and beef myoglobins was achieved in only seven minutes. The methodology was improved by preparing mixtures with different composition percentages of horse and beef meat. By using myoglobin as marker, low amounts (0.50mg/0.50g, w/w; ∼0.1%) of horse meat can be detected and quantified in minced raw meat samples with high reproducibility and sensitivity, thus offering a valid alternative to conventional PCR techniques.

  11. Myoglobin as marker in meat adulteration: a UPLC method for determining the presence of pork meat in raw beef burger.

    PubMed

    Giaretta, Nicola; Di Giuseppe, Antonella M A; Lippert, Martina; Parente, Augusto; Di Maro, Antimo

    2013-12-01

    The identification of meat animal species used in raw burgers is very important with respect to economic and religious considerations. Therefore, international supervisory bodies have implemented procedures to control the employed meat species. In this paper we propose myoglobin as a powerful molecular marker to evaluate the presence of non-declared meat addition in raw beef burgers by using ultra-performance liquid chromatography (UPLC) for the separation and identification of edible animal species (beef, chicken, horse, ostrich, pig and water buffalo). Meat samples were pre-treated with sodium nitrite to transform oxymyoglobin and deoxymyoglobin to the more stable metmyoglobin. The developed method was validated, preparing mixtures with different percentages of pork and beef minced meat. The obtained results show that using myoglobin as marker, 5% (25 mg/500 mg) of pork or beef meat can be detected in premixed minced meat samples.

  12. Ultra performance liquid chromatography PDA method for determination of tigecycline in human plasma.

    PubMed

    D'Avolio, Antonio; Peila, Emanuela; Simiele, Marco; Pensi, Debora; Baietto, Lorena; Cusato, Jessica; Cinnirella, Giacoma; De Rosa, Francesco; Di Perri, Giovanni

    2013-12-01

    : A simple ultra performance liquid chromatography with photodiode array method for the quantification of human plasma concentrations of tigecycline was developed and validated. Quinaxoline, used as an internal standard, was added to 500 μL of plasma before adding 1 mL of protein precipitation solution. The extracts were dried in a vacuum centrifuge system at 60°C and reconstituted with 60 μL of water and acetonitrile (95:5, vol/vol), and 5 μL was injected onto an ACQUITY UPLC H-Class system. Chromatographic separation was performed on a C18 ACQUITY UPLC HSS T3 column using a gradient of potassium phosphate buffer (pH 3.2) and acetonitrile. Detection was performed using a photodiode array detector at 350 nm. Relative error at 3 quality control concentrations ranged from -2.49% to -8.74%. Intraday and interday (percent relative standard error) precision ranged from 3.93% to 12.27% and from 9.53% to 13.32%, respectively. Limit of quantification and limit of detection were 0.024 and 0.006 μg/mL, respectively. Mean recovery was 95%. The calibration curve was linear up to 6 μg/mL. This concentration range proved to be adequate to measure tigecycline concentrations in patients treated with the drug, therefore this method would be suitable for therapeutic drug monitoring.

  13. Early development of the vertebral column.

    PubMed

    Scaal, Martin

    2016-01-01

    The segmental organization of the vertebrate body is most obviously visible in the vertebral column, which consists of a series of vertebral bones and interconnecting joints and ligaments. During embryogenesis, the vertebral column derives from the somites, which are the primary segments of the embryonic paraxial mesoderm. Anatomical, cellular and molecular aspects of vertebral column development have been of interest to developmental biologists for more than 150 years. This review briefly summarizes the present knowledge on early steps of vertebral column development in amniotes, starting from sclerotome formation and leading to the establishment of the anatomical bauplan of the spine composed of vertebral bodies, vertebral arches, intervertebral discs and ribs, and their specific axial identities along the body axis.

  14. Tests on duralumin columns for aircraft construction

    NASA Technical Reports Server (NTRS)

    Lee, John G

    1924-01-01

    The following paper is based on the results of tests, upon duralumin columns, contained in two theses presented to the Department of Civil and Sanitary Engineering of the Massachusetts Institute of Technology.

  15. AVIRIS Spectrometer Maps Total Water Vapor Column

    NASA Technical Reports Server (NTRS)

    Conel, James E.; Green, Robert O.; Carrere, Veronique; Margolis, Jack S.; Alley, Ronald E.; Vane, Gregg A.; Bruegge, Carol J.; Gary, Bruce L.

    1992-01-01

    Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) processes maps of vertical-column abundances of water vapor in atmosphere with good precision and spatial resolution. Maps provide information for meteorology, climatology, and agriculture.

  16. A Versatile, Automatic Chromatographic Column Packing Device

    ERIC Educational Resources Information Center

    Barry, Eugene F.; And Others

    1977-01-01

    Describes an inexpensive apparatus for packing liquid and gas chromatographic columns of high efficiency. Consists of stainless steel support struts, an Automat Getriebmotor, and an associated three-pulley system capable of 10, 30, and 300 rpm. (MLH)

  17. Axisymmetric Column Collapse in a Rotating System

    NASA Astrophysics Data System (ADS)

    Warnett, Jay; Thomas, Peter; Dennisenko, Petr

    2012-11-01

    We discuss experimental and computational results of a study investigating the collapse of an initially axisymmetric cylindrical column of granular material within a rotating environment of air or liquids. In industry this type of granular column collapse that is subject to background rotation is encountered, for instance, in the context of the spreading of powders and fertilizers. In comparison to its non-rotating counterpart the physical characteristics of the column collapse in a rotating system are expected to be modified by effects arising from centrifugal forces and Coriolis forces. We compare our new results for the rotating flow to data available in the literature for the collapse of granular columns in non-rotating systems to highlight the differences observed.

  18. Modeling Tropical Precipitation in a Single Column.

    NASA Astrophysics Data System (ADS)

    Sobel, Adam H.; Bretherton, Christopher S.

    2000-12-01

    A modified formulation of the traditional single column model for representing a limited area near the equator is proposed. This formulation can also be considered a two-column model in the limit as the area represented by one of the columns becomes very large compared to the other. Only a single column is explicitly modeled, but its free tropospheric temperature, rather than its mean vertical velocity, is prescribed. This allows the precipitation and vertical velocity to be true prognostic variables, as in prior analytical theories of tropical precipitation. Two models developed by other authors are modified according to the proposed formulation. The first is the intermediate atmospheric model of J. D. Neelin and N. Zeng, but with the horizontal connections between columns broken, rendering it a set of disconnected column models. The second is the column model of N. O. Rennó, K. A. Emanuel, and P. H. Stone. In the first model, the set of disconnected column models is run with a fixed temperature that is uniform in the Tropics, and insolation, SST, and surface wind speed taken from a control run of the original model. The column models produce a climatological precipitation field that is grossly similar to that of the control run, despite that the circulation implied by the column models is not required to conserve mass. The addition of horizontal moisture advection by the wind from the control run substantially improves the simulation in dry regions. In the second model the sensitivity of the modeled steady-state precipitation and relative humidity to varying SST and wind speed is examined. The transition from shallow to deep convection is simulated in a `Lagrangian' calculation in which the column model is subjected to an SST that increases in time. In this simulation, the onset of deep convection is delayed to a higher SST than in the steady-state case, due to the effect of horizontal moisture advection (viewed in a Lagrangian reference frame). In both of the

  19. Commander prepares glass columns for electrophoresis experiment

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Commander Jack Lousma prepares on of the glass columns for the electrophoresis test in the middeck area of the Columbia. The experiment, deployed in an L-shaped mode in upper right corner, consists of the processing unit with glass columns in which the separation takes place; a camera (partially obscurred by Lousma's face) to document the process; and a cryogenic freezer to freeze and store the samples after separation.

  20. Development and application of a UPLC-MS/MS method for simultaneous determination of fenofibric acid and berberine in rat plasma: application to the drug-drug pharmacokinetic interaction study of fenofibrate combined with berberine after oral administration in rats.

    PubMed

    Li, Guofei; Yang, Fan; Liu, Mei; Su, Xianying; Zhao, Mingming; Zhao, Limei

    2016-07-01

    With the purpose of carrying out pharmacokinetic interaction studies ofnberberine (BBR) and fenofibrate (FBT), an UPLC-MS/MS method has been developed and validated. The analytes, BBR and fenofibric acid (FBA, metabolite of FBT) and the internal standard, tetrahydropalmatine, were extracted with dichloromethane-diethyl ether (3:2, v/v) and separated on an Agilent Eclipse XDB C18 column using a mobile phase composed of acetonitrile and water. With positive ion electrospray ionization, the analytes were monitored on a triple quadrupole mass spectrometer in multiple reaction monitoring mode. Linear calibration curves were obtained over the concentration ranges of 0.1-100.0 ng/mL for BBR and 10.0-50,000.0 ng/mL for FBA. For BBR and FBA, the intra- and inter-day precisions were <11.5 and 11.9%, respectively. The accuracy was within 11.7% and 11.3%. The mean recoveries of BBR at three concentrations of 0.2, 20.0, 80.0 ng/mL were >85.6%, and those of FBA at three concentrations of 20.0, 2500.0, 40,000.0 ng/mL were >87.9%. Consequently, the proposed method was applied to the pharmacokinetic interaction study of FBT combined with BBR after oral administration in rats and was proved to be sensitive, specific and reliable to analyze BBR and FBA in biological samples simultaneously. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Development and validation of a sensitive UPLC-MS/MS method for the quantitation of [(13)C]sucrose in rat plasma, blood, and brain: Its application to the measurement of blood-brain barrier permeability.

    PubMed

    Miah, Mohammad K; Bickel, Ulrich; Mehvar, Reza

    2016-03-15

    Accurate and reproducible measurement of blood-brain barrier (BBB) integrity is critical in the assessment of the pathophysiology of the central nervous system disorders and in monitoring therapeutic effects. The widely-used low molecular weight marker [(14)C]sucrose is non-specific in the absence of chromatographic separation. The purpose of this study was to develop and validate a sensitive and reproducible LC-MS/MS method for the analysis of stable isotope-modified [(13)C12]sucrose in brain, plasma, and blood to determine BBB permeability to sucrose. After addition of internal standard (IS, [(13)C6]sucrose), the marker and IS were recovered from diluted rat blood, plasma, and brain homogenate by protein precipitation using acetonitrile. The recovery of the marker and IS was almost quantitative (90-106%) for all three matrices. The recovered samples were directly injected into an isocratic UPLC system with a run time of 6 min. Mass spectrometry was conducted using multiple reaction monitoring in negative mode. The method was linear (r(2)≥0.99) in the concentration ranges tested for the diluted blood and plasma (10-1000 ng/mL) and brain homogenate (1-200 ng/mL). The lower limit of quantitation of the assay was 0.5 pg injected on column. The assay was validated (n=5) based on acceptable intra- and inter-run accuracy and precision values. The method was successfully used for the measurement of serial blood and plasma and terminal brain concentrations of [(13)C12]sucrose after a single intravenous dose (10 mg/kg) of the marker to rats. As expected, the apparent brain uptake clearance values of [(13)C12]sucrose were low in healthy rats. The method may be useful for determination of the BBB integrity in animal models.

  2. Simultaneous determination of triamcinolone acetonide palmitate and triamcinolone acetonide in beagle dog plasma by UPLC-MS/MS and its application to a long-term pharmacokinetic study of triamcinolone acetonide palmitate lipid emulsion injection.

    PubMed

    Liu, Hui; Yang, Mingjing; Wu, Panpan; Guan, Jiao; Men, Lei; Lin, Hongli; Tang, Xing; Zhao, Yunli; Yu, Zhiguo

    2015-02-01

    In order to investigate the pharmacokinetics of triamcinolone acetonide palmitate (TAP) which is a lipid-soluble prodrug of triamcinolone acetonide (TA), a rapid, simple, sensitive and reproducible UPLC-MS/MS method has been developed and validated for the simultaneous determination of TAP and TA in beagle dog plasma. After simple liquid-liquid extraction, the analytes and internal standard (dexamethasone, DEX) were separated on Phenomenex Luna C18 column (50 mm × 2.1mm, 1.7 μm) using a mobile phase consisting of solvent A (acetonitrile) and solvent B (0.1% ammonia solution) at a flow rate of 0.2 ml/min with gradient elution. Acquisition of mass spectrometric data was performed in multiple reaction monitoring (MRM) mode via positive electrospray ionization using the ion transitions of m/z 673.5→397.3, 435.3→415.3 and 393.3→355.3 for TAP, TA and IS, respectively. The method was of satisfactory specificity, sensitivity, precision and accuracy over the concentration range of 1-1,000 ng/ml for TAP and 0.5-500 ng/ml for TA. The intra- and inter-day precisions for both TAP and TA were 3.2% to 18.7% and the accuracy was in the range of -8.4% to 6.8%. The mean recoveries of TAP, TA and IS were 86.7-104.7%. The method was successfully applied to a long-term pharmacokinetic study of TAP and TA after 28-day repeated intravenous administration of TAP lipid emulsion injection to beagle dogs.

  3. A UPLC-MS/MS Method for Simultaneous Determination of Free and Total Forms of a Phenolic Acid and Two Flavonoids in Rat Plasma and Its Application to Comparative Pharmacokinetic Studies of Polygonum capitatum Extract in Rats.

    PubMed

    Huang, Yong; Sun, Hui-Yuan; Qin, Xiao-Li; Li, Yong-Jun; Liao, Shang-Gao; Gong, Zi-Peng; Lu, Yuan; Wang, Yong-Lin; Wang, Ai-Min; Lan, Yan-Yu; Zheng, Lin

    2017-02-25

    The principal active constituents of Polygonum capitatum are phenolic acids and flavonoids, such as gallic acid, quercitrin, and quercetin. The aim of this study was to develop and validate a method to determine the three constituents and the corresponding conjugated metabolites of Polygonum capitatum in vivo and to conduct pharmacokinetic studies on the herb, a well-known Miao medicinal plant in China. Gallic acid, quercitrin, and quercetin were analysed by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS). Protein precipitation in plasma samples was performed using methanol. For the determination of total forms of analytes, an additional process of hydrolysis was conducted using β-glucuronidase and sulphatase. The analytes were separated on a BEH C18 column (50 mm × 2.1 mm; i.d., 1.7 μm) and quantified by multiple reaction monitoring (MRM) mode. The linear regression showed high linearity over a 729-fold dynamic range for the three analytes. The relative standard deviations of intra- and inter-day measurements were less than 9.5%, and the method was accurate to within -11.1% to 12.5%. The extraction recoveries for gallic acid, quercitrin, and quercetin were 94.3%-98.8%, 88.9%-98.8%, and 95.7%-98.5%, respectively. All samples were stable under short- and long-term storage conditions. The validated method was successfully applied to a comparative pharmacokinetic study of gallic acid, quercitrin, and quercetin in their free and total forms in rat plasma. The study revealed significantly higher exposure of the constituents in total forms for gallic acid and quercetin, while quercitrin was detected mainly in its corresponding free form in vivo. The established method was rapid and sensitive for the simultaneous quantification of free and total forms of multiple constituents of Polygonum capitatum extract in plasma.

  4. The handedness of historiated spiral columns.

    PubMed

    Couzin, Robert

    2016-11-17

    Trajan's Column in Rome (AD 113) was the model for a modest number of other spiral columns decorated with figural, narrative imagery from antiquity to the present day. Most of these wind upwards to the right, often with a congruent spiral staircase within. A brief introductory consideration of antique screw direction in mechanical devices and fluted columns suggests that the former may have been affected by the handedness of designers and the latter by a preference for symmetry. However, for the historiated columns that are the main focus of this article, the determining factor was likely script direction. The manner in which this operated is considered, as well as competing mechanisms that might explain exceptions. A related phenomenon is the reversal of the spiral in a non-trivial number of reproductions of the antique columns, from Roman coinage to Renaissance and baroque drawings and engravings. Finally, the consistent inattention in academic literature to the spiral direction of historiated columns and the repeated publication of erroneous earlier reproductions warrants further consideration.

  5. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    NASA Technical Reports Server (NTRS)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  6. Use of HPLC/UPLC-spectrophotometry for detection of formazan in in vitro Reconstructed human Tissue (RhT)-based test methods employing the MTT-reduction assay to expand their applicability to strongly coloured test chemicals.

    PubMed

    Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P

    2015-06-01

    A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals.

  7. Mass transfer model liquid phase catalytic exchange column simulation applicable to any column composition profile

    SciTech Connect

    Busigin, A.

    2015-03-15

    Liquid Phase Catalytic Exchange (LPCE) is a key technology used in water detritiation systems. Rigorous simulation of LPCE is complicated when a column may have both hydrogen and deuterium present in significant concentrations in different sections of the column. This paper presents a general mass transfer model for a homogenous packed bed LPCE column as a set of differential equations describing composition change, and equilibrium equations to define the mass transfer driving force within the column. The model is used to show the effect of deuterium buildup in the bottom of an LPCE column from non-negligible D atom fraction in the bottom feed gas to the column. These types of calculations are important in the design of CECE (Combined Electrolysis and Catalytic Exchange) water detritiation systems.

  8. [Evaluation of capillary chromatographic columns packed by electrokinetic packing method].

    PubMed

    Li, Z; You, H; Hu, S; Wei, W; Luo, G

    1997-01-01

    In this paper, a method for electrokinetic packing capillary columns is reported. A higher column effeciency was obtained by performing electrochromatography on electrokinetic packing columns. The highest column efficiency in number of theoretical plate per meter was more than 200000, corresponding to reduced plate height less than 2. The reproducibilities of the same column in different intervals and different columns prepared from the same or different batches were compared. The relative standard deviations of the number of theoretical plate and retention time were less than 10% and 8%, respectively. The results indicated that high column efficiency and good reproducibility can be obtained on these new capillary packed columns.

  9. Column selectivity in reversed-phase liquid chromatography. IV. Type-B alkyl-silica columns.

    PubMed

    Gilroy, Jonathan J; Dolan, John W; Snyder, Lloyd R

    2003-06-06

    Columns for reversed-phase HPLC (RP-LC) can be characterized by five, retention-related parameters: H (hydrophobicity), S (steric selectivity), A (hydrogen-bond acidity), B (hydrogen-bond basicity), and C (cation-exchange behavior). In the present study, values of the latter parameters have been measured for 92 type-B (low metals content)alkyl-silica columns and compared to column properties such as ligand length,ligand concentration, pore diameter, and the presence or absence of end-capping. With the exception of five columns of unusual design, retention factors, k, for 16 representative test compounds were correlated with values of H, S, etc., within an average +/- 1.2% (1 standard deviation, SD), suggesting that all significant solute-column interactions are recognized by these five column parameters. A single-valued function F(s) is proposed to measure differences in selectivity for any two RP-LC columns whose values of H, S, etc., are known. This allows the easy selection of columns whose selectivity is desired to be either similar to or different from a starting column, for application in either routine analysis or method development.

  10. Identification of chemical ingredients of peanut stems and leaves extracts using UPLC-QTOF-MS coupled with novel informatics UNIFI platform.

    PubMed

    Deng, Lei; Shi, Ai-Min; Liu, Hong-Zhi; Meruva, Naren; Liu, Li; Hu, Hui; Yang, Ying; Huang, Chun; Li, Peng; Wang, Qiang

    2016-12-01

    Peanut stems and leaves have been used traditionally as both herbal medicines and special food in Asia. In this study, the main functional compounds of peanut stems and leaves extracts were identified using UPLC separation coupled to high resolution mass spectrometry (QTOF-MS), and a traditional medicine library. Three different extraction solvents (ethyl acetate, petroleum ether and n-butanol) were evaluated to prepare the extracts of peanut stems and leaves. A total of 283 chemical compounds were identified in peanut stems and leaves extracts, of which 207 compounds are tentatively new identifications in Genus Arachis. The integration of data acquisition and processing with the traditional medicine library provides a simple, efficient process to effectively facilitate the identification of chemical ingredients in complex natural product extracts. The integrated workflow for separation, detection and identification of functional compounds in natural products using UPLC/QTOF-MS greatly improves productivity for development of traditional herbal medicines. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Comparison of sample preparation methods, validation of an UPLC-MS/MS procedure for the quantification of tetrodotoxin present in marine gastropods and analysis of pufferfish.

    PubMed

    Nzoughet, Judith Kouassi; Campbell, Katrina; Barnes, Paul; Cooper, Kevin M; Chevallier, Olivier P; Elliott, Christopher T

    2013-02-15

    Tetrodotoxin (TTX) is one of the most potent marine neurotoxins reported. The global distribution of this toxin is spreading with the European Atlantic coastline now being affected. Climate change and increasing pollution have been suggested as underlying causes for this. In the present study, two different sample preparation techniques were used to extract TTX from Trumpet shells and pufferfish samples. Both extraction procedures (accelerated solvent extraction (ASE) and a simple solvent extraction) were shown to provide good recoveries (80-92%). A UPLC-MS/MS method was developed for the analysis of TTX and validated following the guidelines contained in the Commission Decision 2002/657/EC for chemical contaminant analysis. The performance of this procedure was demonstrated to be fit for purpose. This study is the first report on the use of ASE as a mean for TTX extraction, the use of UPLC-MS/MS for TTX analysis, and the validation of this method for TTX in gastropods.

  12. Rapid and Sensitive Determination of Major Active Ingredients and Toxic Components in GinkgoBiloba Leaves Extract (EGb 761) by a Validated UPLC-MS-MS Method.

    PubMed

    Wang, Yao; Liu, Yuan; Wu, Qi; Yao, Xin; Cheng, Zongqi

    2017-01-08

    An accurate, precise and sensitive ultra-performance liquid chromatography tandem mass spectrometric (UPLC-MS-MS) method was developed for the determination of flavonoids, terpene lactones, together with ginkgolic acids in Ginkgo biloba leaves extract (EGb 761). This is the first report of the simultaneous analysis of major active ingredients and toxic components in EGb 761 using UPLC-MS-MS. This analysis afforded good linearity, precision, repeatability and accuracy. In addition, the content of those major bioactive components in EGb 761 prepared by different manufacturers of China was determined to establish the effectiveness of the method. The results indicated that the quantification analysis could be readily utilized as a quality control method for EGb 761 and its other related products using flavonoids, terpene lactones and ginkgolic acids as markers.

  13. Ultra performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry for high-sensitivity and high-throughput analysis of U.S. Environmental Protection Agency 16 priority pollutants polynuclear aromatic hydrocarbons.

    PubMed

    Cai, Sheng-Suan; Syage, Jack A; Hanold, Karl A; Balogh, Michael P

    2009-03-15

    In this work, we demonstrate the utility of ultra performance liquid chromatography-atmospheric pressure photoionization-tandem mass spectrometry (UPLC-APPI-MS/MS) for high-sensitivity and high-throughput analysis of United States Environmental Protection Agency (U.S. EPA) 16 priority pollutants polycyclic aromatic hydrocarbons (PAHs). Analyses were performed on a Waters Acquity-TQD equipped with Syagen's PhotoMate APPI source. All 16 PAHs were analyzed on column in approximately 3.5 min with excellent chromatographic separation for all PAH isomers and with low picogram detection limits on column for all analytes using chlorobenzene as a dopant. Dynamic linear ranges were evaluated and found to cover at least 3-4 orders of magnitude. In comparison with the existing U.S. EPA methods, this approach improves instrument sample throughput by at least 10-fold.

  14. A new ultra-pressure liquid chromatography method for the determination of biogenic amines in cheese.

    PubMed

    Mayer, H K; Fiechter, G; Fischer, E

    2010-05-07

    A fast and reliable ultra-performance liquid chromatography (UPLC) method for the determination of biogenic amines (ethanolamine, methylamine, agmatine, histamine, dimethylamine, ethylamine, octopamine, pyrrolidine, dopamine, isopropylamine, propylamine, tyramine, putrescine, butylamine, cadaverine, tryptamine, 2-phenylethylamine, 3-methylbutylamine, spermidine, spermine) in cheese was established. After pre-column derivatization with 6-aminoquinolyl-N-hydroxy-succinimidyl carbamate (AQC), 20 primary and secondary biogenic amines were separated on an Acquity UPLC column (BEH C(18), 1.7 microm; 2.1 mm x 50 mm) within 9 min. Limits of detection (mg/100g cheese) ranged from 0.04 (ethanolamine) to 1.62 (spermine), and limits of quantification were between 0.16 (ethanolamine) and 6.09 (spermine). The UPLC method was applied to the analysis of 58 cheese samples as retailed in Austria. About 13.8% of samples had a histamine content above 10mg/100g, and 22.4% had a tyramine content above 10mg/100g. Moreover, 8.6% of samples had a putrescine or cadaverine content higher than 10mg/100g. The total concentration of biogenic amines in two cheese samples was about 194 mg/100g. Thus, obligatory monitoring of biogenic amines should be considered to ensure quality of cheese in future.

  15. Purification of matrix metalloproteinases by column chromatography.

    PubMed

    Imai, Kazushi; Okada, Yasunori

    2008-01-01

    Matrix metalloproteinases (MMPs) are zinc endopeptidases composed of 23 members in humans, which belong to a subfamily of the metzincin superfamily. They play important roles in many pathophysiological events including development, organogenesis, angiogenesis, tissue remodeling and destruction, and cancer cell proliferation and progression by degradation of extracellular matrix (ECM) and non-ECM proteins and interaction with various molecules. Here, we present standard protocols for purification of native proMMPs (proMMP-1, -2, -3, -7, -9 and -10) and recombinant MT1-MMP (MMP-14) using conventional column chromatography. Purification steps comprise the initial common step [diethylaminoethyl (DEAE)-cellulose, Green A Dyematrex gel and gelatin-Sepharose columns], the second step for removal of nontarget proMMPs by immunoaffinity columns (anti-MMP-1 and/or anti-MMP-3 IgG-Sepharose columns) and the final step for further purification (IgG-Sepharose, DEAE-cellulose, Zn2+-chelate-Sepharose and/or gel filtration columns). Purified proMMPs and MMP are functionally active and suitable for biochemical analyses. The basic protocol for the purification from culture media takes approximately 7-10 d.

  16. Modeling of rotating disc contactor (RDC) column

    NASA Astrophysics Data System (ADS)

    Ismail, Wan Nurul Aiffah; Zakaria, Siti Aisyah; Noor, Nor Fashihah Mohd; Sulong, Ibrahim; Arshad, Khairil Anuar

    2014-12-01

    Liquid-liquid extraction is one of the most important separation processes. Different kinds of liquid-liquid extractor such as Rotating Disc Contactor (RDC) Column being used in industries. The study of liquid-liquid extraction in an RDC column has become a very important subject to be discussed not just among chemical engineers but mathematician as well. In this research, the modeling of small diameter RDC column using the chemical system involving cumene/isobutryric asid/water are analyzed by the method of Artificial Neural Network (ANN). In the previous research, we begin the process of analyzed the data using methods of design of the experiments (DOE) to identify which factor and their interaction factor are significant and to determine the percentage of contribution of the variance for each factor. From the result obtained, we continue the research by discussed the development and validation of an artificial neural network model in estimating the concentration of continuous and concentration of dispersed outlet for an RDC column. It is expected that an efficient and reliable model will be formed to predict RDC column performance as an alternative to speed up the simulation process.

  17. Analysis of E. rutaecarpa Alkaloids Constituents In Vitro and In Vivo by UPLC-Q-TOF-MS Combined with Diagnostic Fragment

    PubMed Central

    Yang, Shenshen; Tian, Meng; Yuan, Lei; Deng, Haoyue; Wang, Lei; Li, Aizhu; Hou, Zhiguo; Li, Yubo

    2016-01-01

    Evodia rutaecarpa (Juss.) Benth. (Rutaceae) dried ripe fruit is used for dispelling colds, soothing liver, and analgesia. Pharmacological research has proved that alkaloids are the main active ingredients of E. rutaecarpa. This study aimed to rapidly classify and identify the alkaloids constituents of E. rutaecarpa by using UPLC-Q-TOF-MS coupled with diagnostic fragments. Furthermore, the effects of the material base of E. rutaecarpa bioactive ingredients in vivo were examined such that the transitional components in the blood of rats intragastrically given E. rutaecarpa were analyzed and identified. In this study, the type of alcohol extraction of E. rutaecarpa and the corresponding blood sample were used for the analysis by UPLC-Q-TOF-MS in positive ion mode. After reviewing much of the literature and collected information on the fragments, we obtained some diagnostic fragments of the alkaloids. Combining the diagnostic fragments with the technology of UPLC-Q-TOF-MS, we identified the compounds of E. rutaecarpa and blood samples and compared the ion fragment information with that of the alkaloids in E. rutaecarpa. A total of 17 alkaloids components and 6 blood components were identified. The proposed method was rapid, accurate, and sensitive. Therefore, this technique can reliably and practically analyze the chemical constituents in traditional Chinese medicine (TCM). PMID:27446630

  18. Qualitative and quantitative analysis data of the major constituents of Ilex paraguariensis leaves by UPLC-PDA and QTOF-MS.

    PubMed

    Blum-Silva, Carlos Henrique; Luz, Ana Beatriz Gobbo; Nascimento, Marcus Vinicius P S; de Campos Facchin, Bruno Matheus; Baratto, Bruna; Fröde, Tânia Silvia; Sandjo, Louis Pergaud; Dalmarco, Eduardo Monguilhott; Reginatto, Flávio Henrique

    2016-09-01

    Ilex paraguariensis A. St. Hil. is a native plant of South America widely consumed as beverages for its ethno pharmacological properties, such as antioxidant, anti-inflammatory, hypocholesterolemic as well as its benefits on the cardiovascular system. Since these properties are related to its chemical composition, the identification and quantification of the major compounds of I. paraguariensis extracts still remains relevant. The data described in this article supports previous results on the anti-inflammatory effect of I. paraguariensis A. St. Hil (Mate), "The anti-inflammatory effect of I. paraguariensis A. St. Hil (Mate) in a murine model of pleurisy" [1]. The present data article reports on nine major compounds identified in I. paraguariensis extracts and its related fractions by using UPLC-PDA and UPLC-QTOF. Identification of the constituents was based on their retention times, UV absorption spectra and mass spectra data, as well as by comparison with authentic samples. The validated parameters show that the quantification by UPLC-PDA methodology developed is sensitive, precise and accurate.

  19. Simultaneous quantification method for comparative pharmacokinetics studies of two major metabolites from geniposide and genipin by online mircrodialysis-UPLC-MS/MS.

    PubMed

    Zhang, Xueju; Liu, Shu; Pi, Zifeng; Liu, Zhiqiang; Song, Fengrui

    2017-01-15

    Genipin-1-o-glucuronic acid and genipin-monosulfate are two major metabolites from geniposide and genipin. Based on diabetic rat model, we developed a simultaneous quantification method to investigate their comparative pharmacokinetics by online mircrodialysis-ultra performance liquid chromatography-mass spectrometry (MD-UPLC-MS/MS) without their standard compounds. Online microdialysis sampling could avoid unexpected contamination or degradation of the analytes during the storage and transfer steps. Combined with good sensitivity, selectivity and selectivity of UPLC-MS/MS, online MD-UPLC-MS/MS method could real-timely monitor metabolites in rat blood for quantitative analysis. Our research found that AUC0→t of genipin-1-o-glucuronic acid and genipin-monosulfate in blood of diabetic group were 17.68 and 7.58 times than those in normal group, respectively, and AUC0→t of genipin-1-o-glucuronic acid was 2.28 times than that of genipin-monosulfate in blood of diabetic group, which revealed the effect of diabetes on the pharmacokinetic properties of the two metabolites. This study not only provides an approach for pharmacokinetic studies for various metabolites from herb medicines, but also can predict druggability of their bioactive metabolites. The insight obtained should facilitate drug development and toxicity research.

  20. Comparison of the kinetic performance of different columns for fast liquid chromatography, emphasizing the contributions of column end structure.

    PubMed

    Lambert, Nándor; Miyazaki, Shota; Ohira, Masayoshi; Tanaka, Nobuo; Felinger, Attila

    2016-11-18

    The kinetic performance of five chromatographic columns designed for fast liquid chromatography with different column packing materials - including fully porous (2.0 and 1.9μm particles), core-shell (2.6μm particles) or monolithic packings - with identical column dimensions (2.1×50mm) was tested. Since the tested monolithic column showed systematically better efficiency for early eluting compounds than the packed columns, an additional band broadening effect was suspected for the packed columns. The effects of the presence of the frits and the bed heterogeneity of the columns near the frits were characterized by a column-reversal method. It has been shown that significant differences - even 20-25% difference in efficiency - can exist between the two ends of the packed columns, while the monolithic column shows rather similar performance at either column end.

  1. Methylmercury production in the marine water column

    NASA Astrophysics Data System (ADS)

    Topping, G.; Davies, I. M.

    1981-03-01

    Although the biosynthesis of methylmercury in sediments is well established1, this is not necessarily the exclusive natural source of methylmercury entering the marine food chain, particularly commercial fish and shellfish species for human consumption. An examination of mercury levels in freshwater fish2, collected from a lake with a history of industrial mercury contamination, suggested that levels in fish are controlled in part by mercury in suspension and it followed that methylation should occur in the water column. Although methylmercury is present in seawater in coastal areas receiving discharges of waste containing either inorganic mercury3 or methylmercury4 there is no evidence that methylmercury is actually formed in the water column. We now present data which demonstrate that inorganic mercury can be methylated in the water column and we compare this production with that known to occur in marine sediments.

  2. Non-planar microfabricated gas chromatography column

    DOEpatents

    Lewis, Patrick R.; Wheeler, David R.

    2007-09-25

    A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

  3. Neutron camera employing row and column summations

    SciTech Connect

    Clonts, Lloyd G.; Diawara, Yacouba; Donahue, Jr, Cornelius; Montcalm, Christopher A.; Riedel, Richard A.; Visscher, Theodore

    2016-06-14

    For each photomultiplier tube in an Anger camera, an R.times.S array of preamplifiers is provided to detect electrons generated within the photomultiplier tube. The outputs of the preamplifiers are digitized to measure the magnitude of the signals from each preamplifier. For each photomultiplier tube, a corresponding summation circuitry including R row summation circuits and S column summation circuits numerically add the magnitudes of the signals from preamplifiers for each row and for each column to generate histograms. For a P.times.Q array of photomultiplier tubes, P.times.Q summation circuitries generate P.times.Q row histograms including R entries and P.times.Q column histograms including S entries. The total set of histograms include P.times.Q.times.(R+S) entries, which can be analyzed by a position calculation circuit to determine the locations of events (detection of a neutron).

  4. Final Report, Distillation Column Flooding Predictor

    SciTech Connect

    George E. Dzyacky

    2003-05-31

    The Flooding Predictor is an advanced process control strategy comprising a patented pattern-recognition methodology that identifies pre-flood patterns discovered to precede flooding events in distillation columns. The grantee holds a U.S. patent on the modeling system. The technology was validated at the Separations Research Program, The University of Texas at Austin under a grant from the U. S. Department of Energy, Inventions & Innovation Program. Distillation tower flooding occurs at abnormally high vapor and/or liquid rates. The loss in tray efficiencies is attributed to unusual behavior of liquid inventories inside the column leading to conditions of flooding of the space in between trays with liquid. Depending on the severity of the flood condition, consequences range from off spec products to equipment damage and tower shutdown. This non-intrusive pattern recognition methodology, processes signal data obtained from existing column instrumentation. Once the pattern is identified empirically, it is modeled and coded into the plant's distributed control system. The control system is programmed to briefly "unload" the tower each time the pattern appears. The unloading takes the form of a momentary reduction in column severity, e.g., decrease bottom temperature, reflux or tower throughput. Unloading the tower briefly at the pre-flood state causes long-term column operation to become significantly more stable - allowing an increase in throughput and/or product purity. The technology provides a wide range of value between optimization and flooding. When a distillation column is not running at capacity, it should be run in such a way ("pushed") that optimal product purity is achieved. Additional benefits include low implementation and maintenance costs, and a high level of console operator acceptance. The previous commercial applications experienced 98% uptime over a four-year period. Further, the technology is unique in its ability to distinguish between different

  5. Desulfurization of coal by microbial column flotation.

    PubMed

    Ohmura, N; Saiki, H

    1994-06-05

    Twenty-three strains capable of oxidizing iron were isolated from coal and ore storage sites as well as coal and ore mines, volcanic areas, and hot spring. Four strains were found to have high iron-oxidizing activity. One strain (T-4) was selected for this experiment since the strain showed the fastest leaching rate of iron and sulfate from pyrite among the four strains. The T-4 strain was assigned for Thiobacillus ferrooxidans from its cultural and morphological characteristics.Bacterial treatment was applied to column flotation. An increase of cell density in the microbial column flotation resulted in the increase of pyrite removal from a coal-pyrite mixture (high sulfur imitated coal) with corresponding decrease of coal recovery. The addition of kerosene into the microbial column flotation increased the recovery of the imitated coal from 55% (without kerosene) to 81% (with 50 microL/L kerosene) with the reduction of pyrite sulfur content from 11% (feed coal) to 3.9% (product coal). The kerosene addition could reduce the pyritic sulfur content by collecting the coal in the recovery. However, the addition could not enhance separation of pyrite from the coal-pyrite mixture, since pyrite rejection was not affected by the increase of the kerosene addition. An excellent separation was obtained by the microbial flotation using a long column which had a length-diameter (L/D) ratio of 12.7. The long column flotation reduced the pyritic sulfur content from 11% (feed coal) to 1.8% (product coal) when 80% of the feed coal was recovered without the kerosene addition. The long column flotation not only attained an excellent separation but also reduced the amount of cells for desulfurization to as little as one-tenth of the reported amount.

  6. CUB DI (Deionization) column control system

    SciTech Connect

    K. C. Seino

    1999-07-02

    For the old MR (Main Ring), deionization was done with two columns in CUB, using an ion exchange process. Typically 65 GPM of LCW flew through a column, and the resistivity was raised from 3 Mohm-cm to over 12 Mohm-cm. After a few weeks, columns lost their effectiveness and had to be regenerated in a process involving backwashing and adding hydrochloric acid and sodium hydroxide. For normal MR operations, LCW returned from the ring and passed through the two columns in parallel for deionization, although the system could have been operated satisfactorily with only one in use. A 3000 gallon reservoir (the Spheres) provided a reserve of LCW for allowing water leaks and expansions in the MR. During the MI (Main Injector) construction period, the third DI column was added to satisfy requirements for the MI. When the third column was added, the old regeneration controller was replaced with a new controller based on an Allen-Bradley PLC (i.e., SLC-5/04). The PLC is widely used and well documented, and therefore it may allow us to modify the regeneration programs in the future. In addition to the above regeneration controller, the old control panels (which were used to manipulate pumps and valves to supply LCW in Normal mode and to do Int. Recir. (Internal Recirculation) and Makeup) were replaced with a new control system based on Sixtrak Gateway and I/O modules. For simplicity, the new regeneration controller is called as the US Filter system, and the new control system is called as the Fermilab system in this writing.

  7. Optical Measurement Technique for Space Column Characterization

    NASA Technical Reports Server (NTRS)

    Barrows, Danny A.; Watson, Judith J.; Burner, Alpheus W.; Phelps, James E.

    2004-01-01

    A simple optical technique for the structural characterization of lightweight space columns is presented. The technique is useful for determining the coefficient of thermal expansion during cool down as well as the induced strain during tension and compression testing. The technique is based upon object-to-image plane scaling and does not require any photogrammetric calibrations or computations. Examples of the measurement of the coefficient of thermal expansion are presented for several lightweight space columns. Examples of strain measured during tension and compression testing are presented along with comparisons to results obtained with Linear Variable Differential Transformer (LVDT) position transducers.

  8. Complex osteotomies vertebral column resection and decancellation.

    PubMed

    Obeid, Ibrahim; Bourghli, Anouar; Boissière, Louis; Vital, Jean-Marc; Barrey, Cédric

    2014-07-01

    Pedicle subtraction osteotomy (PSO) is nowadays widely used to treat sagittal imbalance. Some complex malalignment cases cannot be treated by a PSO, whereas the imbalance is coronal or mixed or the sagittal imbalance is major and cannot be treated by a single PSO. The aim of this article was to review these complex situations--coronal imbalance, mixed imbalance, two-level PSO, vertebral column resection, and vertebral column decancellation, and to focus on their specificities. It wills also to evoke the utility of navigation in these complex cases.

  9. Physical model studies of water column separation

    NASA Astrophysics Data System (ADS)

    Autrique, R.; Rodal, E.; Sánchez, A.; Carmona, L.

    2012-11-01

    Results of physical model studies of water column separation following an upstream valve closure in a horizontal pipe are presented, using three dimensionless parameters: the magnitude of the transient, M, or the ratio between the Joukowsky pressure and the initial absolute head; ΔHr, or the ratio between the maximum overpressure and the Joukowsky pressure, and tcr, the duration of the vapor cavity relative to the pipeline period. Conclusions are derived, aiming to a better understanding of water column separation extreme pressures and to the establishment of useful preliminary design guidelines.

  10. Laboratory studies of water column separation

    NASA Astrophysics Data System (ADS)

    Autrique, R.; Rodal, E.

    2013-12-01

    Results of experimental studies of water column separation following an upstream valve closure are presented. Different geometrical arrangements with transparent PVC pipes are installed immediately downstream of the closing valve, namely, horizontal pipes, vertical pipes flowing down, and humpback profile pipes, the last two being used in order to obtain full pipe section vapor cavities. Maximum over pressures at water column rejoining, and maximum cavity lengths and duration, are compared with theoretical values and with previous experiments with horizontal pipes. Good agreement is found between theory and experiments, and interesting visual material is obtained.

  11. The industrial practice and development of flotation column in China

    SciTech Connect

    Liu Jiongtian; Zhang Shuangquan

    1997-12-31

    This paper reviewed the developing course of the flotation column since the 1960`s in China. Based on the practical data from several coal preparation plants, two types of flotation columns (the pressure aerated column and the jetting-cyclone column) were compared by their operation, performance and the reasons why they succeeded in the coal industry in China. The paper points out that the flotation column has come into commercial use and has good application prospects in China.

  12. Column selectivity in reversed-phase liquid chromatography. VI. Columns with embedded or end-capping polar groups.

    PubMed

    Wilson, N S; Gilroy, J; Dolan, J W; Snyder, L R

    2004-02-13

    A previous model of column selectivity for reversed-phase liquid chromatography (RP-LC) has been applied to an additional 21 columns with embedded or end-capping polar groups (EPGs). Embedded-polar-group columns exhibit a significantly different selectivity vs. non-EPG, type-B columns, generally showing preferential retention of hydrogen-bond donors, as well as decreased retention for hydrogen-bond acceptors or ionized bases. EPG-columns are also generally less hydrophobic (more polar) than are non-EPG-columns. Interestingly, columns with polar end-capping tend to more closely resemble non-EPG columns, suggesting that the polar group has less effect on column selectivity when used to end-cap the column versus the case of an embedded polar group. Column selectivity data reported here for EPG-columns can be combined with previously reported values for non-EPG columns to provide a database of 154 different columns. This enables a comparison of any two of these columns in terms of selectivity. However, comparisons that involve EPG columns are more approximate.

  13. Systems for column-based separations, methods of forming packed columns, and methods of purifying sample components

    DOEpatents

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.

    2000-01-01

    The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.

  14. Systems For Column-Based Separations, Methods Of Forming Packed Columns, And Methods Of Purifying Sample Components.

    DOEpatents

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.

    2004-08-24

    The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.

  15. Systems For Column-Based Separations, Methods Of Forming Packed Columns, And Methods Of Purifying Sample Components

    DOEpatents

    Egorov, Oleg B.; O'Hara, Matthew J.; Grate, Jay W.; Chandler, Darrell P.; Brockman, Fred J.; Bruckner-Lea, Cynthia J.

    2006-02-21

    The invention encompasses systems for column-based separations, methods of packing and unpacking columns and methods of separating components of samples. In one aspect, the invention includes a method of packing and unpacking a column chamber, comprising: a) packing a matrix material within a column chamber to form a packed column; and b) after the packing, unpacking the matrix material from the column chamber without moving the column chamber. In another aspect, the invention includes a system for column-based separations, comprising: a) a fluid passageway, the fluid passageway comprising a column chamber and a flow path in fluid communication with the column chamber, the flow path being obstructed by a retaining material permeable to a carrier fluid and impermeable to a column matrix material suspended in the carrier fluid, the flow path extending through the column chamber and through the retaining material, the flow path being configured to form a packed column within the column chamber when a suspension of the fluid and the column matrix material is flowed along the flow path; and b) the fluid passageway extending through a valve intermediate the column chamber and the retaining material.

  16. Optimization and simulation of tandem column supercritical fluid chromatography separations using column back pressure as a unique parameter.

    PubMed

    Wang, Chunlei; Tymiak, Adrienne A; Zhang, Yingru

    2014-04-15

    Tandem column supercritical fluid chromatography (SFC) has demonstrated to be a useful technique to resolve complex mixtures by serially coupling two columns of different selectivity. The overall selectivity of a tandem column separation is the retention time weighted average of selectivity from each coupled column. Currently, the method development merely relies on extensive screenings and is often a hit-or-miss process. No attention is paid to independently adjust retention and selectivity contributions from individual columns. In this study, we show how tandem column SFC selectivity can be optimized by changing relative dimensions (length or inner diameter) of the coupled columns. Moreover, we apply column back pressure as a unique parameter for SFC optimization. Continuous tuning of tandem column SFC selectivity is illustrated through column back pressure adjustments of the upstream column, for the first time. In addition, we show how and why changing coupling order of the columns can produce dramatically different separations. Using the empirical mathematical equation derived in our previous study, we also demonstrate a simulation of tandem column separations based on a single retention time measurement on each column. The simulation compares well with experimental results and correctly predicts column order and back pressure effects on the separations. Finally, considerations on instrument and column hardware requirements are discussed.

  17. On Row Rank Equal Column Rank

    ERIC Educational Resources Information Center

    Khalili, Parviz

    2009-01-01

    We will prove a well-known theorem in Linear Algebra, that is, for any "m x n" matrix the dimension of row space and column space are the same. The proof is based on the subject of "elementary matrices" and "reduced row-echelon" form of a matrix.

  18. Desulfurization of coal by microbial column flotation

    SciTech Connect

    Ohmura, Naoya; Saiki, Hiroshi . Dept. of Biotechnology)

    1994-06-05

    Twenty-three strains capable of oxidizing iron were isolated from coal and ore storage sites as well as coal and ore mines, volcanic areas, and hot spring. Four strains were found to have high iron-oxidizing activity. One strain (T-4) was selected for this experiment since the strain showed the fastest leaching rate of iron and sulfate from pyrite among the four strains. The T-4 strain was assigned for Thiobacillus ferrooxidans from its cultural and morphological characteristics. Bacterial treatment was applied to column flotation. An increase of cell density in the microbial column flotation resulted in the increase of pyrite removal from a coal-pyrite mixture with corresponding decrease of coal recovery. The addition of kerosene into the microbial column flotation increased the recovery of the imitated coal from 55% (without kerosene) to 81% (with 50 [mu]L/L kerosene) with the reduction of pyrite sulfur content from11% (feed coal) to 3.9% (product coal). An excellent separation was obtained by the microbial flotation using a long column which had a length-diameter (L/D) ratio of 12.7.

  19. Column densities of interstellar molecular hydrogen

    NASA Technical Reports Server (NTRS)

    Spitzer, L., Jr.; Cochran, W. D.; Hirshfeld, A.

    1974-01-01

    Equivalent widths of some 50 lines in the 0-0 to 5-0 Lyman bands of H2 are reported in the spectra of 28 stars. Curves of growth are given and column densities for levels from J = 0 to J = 5 are tabulated, with a few values and upper limits for N(6) and N(7), together with values for b, the velocity spread parameter. In three Orion stars and in rho Leo pairs of components are detected, the difference in radial velocity is determined, and column densities are measured or estimated; tentative identifications are made with the components observed by Hobbs (1969) in the Na D-lines. Column densities for HD are given for 13 stars. Upper limits for column densities in the first and second vibrational levels are listed for several stars; the ratio of N(J = 0) in the v double prime = 1 level to that in the ground vibrational level is less than 2.4 x 10 to the minus 8th power in zeta Oph. Values of a rotational excitation temperature for the higher J levels are given for all the stars. Data are presented which show an apparent increase of velocity dispersion with J for a number of stars, as measured both from the curves of growth and from line widths.

  20. Water Column Variability in Coastal Regions

    DTIC Science & Technology

    2016-06-07

    biomass. This paper is in press in Marine Ecology Progress Series. Figure 1. SST image on 8 July 1999 of waters Figure 2. Buoy for water column...Remote sensing observation of winter phytoplankton blooms southwest of the Luzon Strait. Marine Ecology Progress Series, In Press. Tang, D.L., Ni, I.-H

  1. WATER COLUMN DATA AND SPECTRAL IRRADIANCE MODEL

    EPA Science Inventory

    Water samples collected monthly, for 18 months, from six sites in the Laguna Madre were analyzed to identify and quantify phytopigments using High Performance Liquid Chromatography (HPLC). In addition, water column pigment and nutrient data were acquired at 12 stations in Upper ...

  2. Constrained optimal design of columns against buckling.

    NASA Technical Reports Server (NTRS)

    Frauenthal, J. C.

    1972-01-01

    The buckling loads of straight, simply supported columns, loaded by axial thrust are maximized, subject to the restriction that the available volume of structural material is specified. In addition, a constraint is placed upon the maximum allowable prebuckling stress. Analytic solutions are presented for a variety of different cross-sectional geometries.

  3. Inklings: Collected Columns on Leadership and Creativity.

    ERIC Educational Resources Information Center

    Campbell, David P.

    This book brings together 35 of David P. Campbell's essays originally published as a regular column in a quarterly publication called "Issues and Observations." The articles deal with topics ranging from leadership issues such as risk-taking, executive motivation, decision making, and corporate taboos, to more general concerns such as…

  4. Contexts for Column Addition and Subtraction

    ERIC Educational Resources Information Center

    Lopez Fernandez, Jorge M.; Velazquez Estrella, Aileen

    2011-01-01

    In this article, the authors discuss their approach to column addition and subtraction algorithms. Adapting an original idea of Paul Cobb and Erna Yackel's from "A Contextual Investigation of Three-Digit Addition and Subtraction" related to packing and unpacking candy in a candy factory, the authors provided an analogous context by…

  5. "Dry-column" chromatography of plant pigments

    NASA Technical Reports Server (NTRS)

    Woeller, F. H.; Lehwalt, M. F.; Oyama, V. I.

    1973-01-01

    Separation of plant pigments which can be accomplished on thin-layer silica plates with mixture of petroleum ether, halocarbon, acetone, and polar solvent can be readily translated into dry-column technique that yields reproducible chromatograms after elution in fashion of liquid chromatography with fluorimeter as detector. Best solvent system was found to be mixture of petroleum ether, dichloromethane, acetone, and ethyl acetate.

  6. Pilot scale benzene stripping column testing: Review of test data and application to the ITP columns

    SciTech Connect

    Georgeton, G.K.; Gaughan, T.P.; Taylor, G.A.

    1993-09-10

    Radioactive cesium will be removed from aqueous high level waste (HLW) solutions by precipitation with sodium tetraphenyl borate (TPB) in the In-Tank Precipitation (ITP) process. Benzene is generated due to the radiolysis of TPB, and dissolves into the decontaminated salt solution (DSS) and into the water used to wash (WW) the precipitate. These solutions will be processed through stripping columns to reduce the benzene concentration to satisfy limits for disposal of the DSS and for temporary storage of the WW. A pilot scale testing program to evaluate the stripping column operation in support of ITP startup activities has been completed. Equipment and test plans were developed so that data obtained from the pilot scale testing would be directly applicable to full scale column operation and could be used to project hydraulic performance and stripping efficiency of both columns. A review of the test data indicate that the ITP stripping columns will be capable of reducing benzene concentrations in salt solutions to satisfy Saltstone and Tank 22 acceptance limits. An antifoam (AF) will be required to maintain the column differential pressure below the vendor recommendation of 40 inches wc so that design feed rates can be achieved. Additionally, the testing program indicated that the nitrogen rate can be decreased from the ITP column design rates and still satisfy benzene concentration requirements in the product.

  7. A method for determining the column curve from tests of columns with equal restraints against rotation on the ends

    NASA Technical Reports Server (NTRS)

    Lundquist, Eugene E; Rossman, Carl A; Houbolt, John C

    1943-01-01

    The results are presented of a theoretical study for the determination of the column curve from tests of column specimens having ends equally restrained against rotation. The theory of this problem is studied and a curve is shown relating the fixity coefficient c to the critical load, the length of the column, and the magnitude of the elastic restraint. A method of using this curve for the determination of the column curve for columns with pin ends from tests of columns with elastically restrained ends is presented. The results of the method as applied to a series of tests on thin-strip columns of stainless steel are also given.

  8. Simultaneous detection and comparative pharmacokinetics of amoxicillin, clavulanic acid and prednisolone in cows' milk by UPLC-MS/MS.

    PubMed

    Liu, Yuan; Zhu, Kui; Wang, Jianfen; Huang, Xiaoyong; Wang, Guanlin; Li, Congying; Cao, Jie; Ding, Shuangyang

    2016-01-01

    Amoxicillin (AMOX), clavulanic acid (CLAV) and prednisolone (PSL) are widely used in combination for the treatment of mastitis in lactating dairy cows. However, no method has been reported to detect these three chemicals in milk in a single assay. In the present work, a reliable and sensitive UPLC-MS/MS method was developed and validated for simultaneous determination of AMOX, CLAV and PSL in cow's milk. The analytes were determined by a positive and negative ionization electrospray mass spectrometer via multiple reaction monitoring. The linear ranges of AMOX, CLAV and PSL were from 2 to 1000ng/mL, 20-1000ng/mL and 1-1000ng/mL, respectively, with the correlation coefficients greater than 0.999. The limits of quantification (LOQs) were 2ng/mL (AMOX), 20ng/mL (CLAV) and 1ng/mL (PSL). Recoveries of the analytes of interest in milk samples were in the ranges of 84.2-101.4%. The intra-day and inter-day precisions ranged from 1.8% to 11.9%. This method was successfully applied to investigate the pharmacokinetics of AMOX, CLAV and PSL in milk from healthy and mastitic cows. The elimination times of AMOX and PSL in mastitic cows were longer than that in healthy cows, but the elimination times of CLAV did not show significant difference.

  9. Investigation on metabolism and pharmacokinetics of triclosan in rat plasma by using UPLC-triple quadrupole MS.

    PubMed

    Wu, Jianlin; Yue, Hao; Cai, Zongwei

    2009-09-01

    Triclosan has been widely used as a disinfectant in human health care products. Although this particular chemical is less toxic, its biotransformation products might have toxicity to human. Therefore, understanding the pharmacokinetics and metabolism of triclosan in animal and human body is important. Plasma samples from SD rats collected after the oral administration of 5 mg/kg triclosan were analyzed by ultra performance liquid chromatography (UPLC)-triple quadrupole mass spectrometry (TQMS) to support the pharmacokinetic study of triclosan. The method development was conducted with selected-ion-recording (SIR, also called SIM for selected-ion-monitoring) mode in ESI-MS and multiple-ion-monitoring (MRM) mode in MS/MS and the obtained results were compared. While MRM provided lower detection limits, its other method validation parameters were worse than those of SIR due to the poor fragmentation of triclosan. The developed SIR method provided limit of quantification of 10.8 ng/mL in plasma. The recovery, accuracy, precision and repeatability were satisfactory. The pharmacokinetic data of triclosan in the rats were presented including the half time of elimination that was (48.5 +/- 10.5) h, indicating that the elimination of triclosan in the rat was slow. Two hydroxylated and sulfonated triclosan, one glucuronidated triclosan, and one sulfonated triclosan were identified in the rat plasma samples.

  10. In Vivo Metabolism Study of Xiamenmycin A in Mouse Plasma by UPLC-QTOF-MS and LC-MS/MS

    PubMed Central

    Lei, Feng; Gao, Du; Zhang, Xi; Xu, Jun; Xu, Min-Juan

    2015-01-01

    Xiamenmycin A is an antifibrotic leading compound with a benzopyran skeleton that is isolated from mangrove-derived Streptomyces xiamenensis. As a promising small molecule for fibrotic diseases, less information is known about its metabolic characteristics in vivo. In this study, the time-course of xiamenmycin A in mouse plasma was investigated by relative quantification. After two types of administration of xiamenmycin A at a single dose of 10 mg/kg, the plasma concentrations were measured quantitatively by LC-MS/MS. The dynamic changes in the xiamenmycin A concentration showed rapid absorption and quick elimination in plasma post-administration. Four metabolites (M1–M4) were identified in blood by UPLC-QTOF-MS, and xiamenmycin B (M3) is the principal metabolite in vivo, as verified by comparison of the authentic standard sample. The structures of other metabolites were identified based on the characteristics of their MS and MS/MS data. The newly identified metabolites are useful for understanding the metabolism of xiamenmycin A in vivo, aiming at the development of an anti-fibrotic drug candidate for the therapeutic treatment of excessive fibrotic diseases. PMID:25636156

  11. UPLC-DAD/Q-TOF-MS Based Ingredients Identification and Vasorelaxant Effect of Ethanol Extract of Jasmine Flower.

    PubMed

    Yin, Yongqiang; Ying, Xuhui; Luan, Hairong; Zhao, Zhenying; Lou, Jianshi; Wang, Deli; Li, Hailin; Wu, Hong

    2014-01-01

    Chinese people commonly make jasmine tea for recreation and health care. Actually, its medicinal value needs more exploration. In this study, vasorelaxant effect of ethanol extract of jasmine flower (EEJ) on isolated rat thoracic aorta rings was investigated and [Ca(2+)] was determined in vascular smooth muscle cells by laser scanning confocal microscope (LSCM). The result of aorta rings showed that EEJ could cause concentration-dependent relaxation of endothelium-intact rings precontracted with phenylephrine or KCl which was attenuated after preincubation of the rings with L-NAME and three different K(+) channel inhibitors; however, indomethacin and glibenclamide did not affect the vasodilatation of EEJ. In addition, EEJ could inhibit contraction induced by PE on endothelium-denuded rings in Ca(2+)-free medium as well as by accumulation of Ca(2+) in Ca(2+)-free medium with high K(+). LSCM also showed that EEJ could lower the elevated level of [Ca(2+)] induced by KCl. These indicate that the vasodilation of EEJ is in part related to causing the release of nitric oxide, activation of K(+) channels, inhibition of influx of excalcium, and release of calcium from sarcoplasmic reticulum. A total of 20 main ingredients, were identified in EEJ by UPLC-DAD/Q-TOF-MS. The vasodilation activity should be attributed to the high content of flavonoid glycosides and iridoid glycosides found in EEJ.

  12. UPLC TOF MS for sensitive quantification of naturally occurring pyrrolizidine alkaloids in Petasites hybridus extract (Ze 339).

    PubMed

    Schenk, Alexander; Siewert, Beate; Toff, Stephan; Drewe, Jürgen

    2015-08-01

    Due to increasing regulatory awareness of their hepatotoxic, genotoxic and possibly carcinogenic potential, pyrrolizidine alkaloid (PA) content has to be thoroughly monitored in herbal medicinal preparations. Recently, new very low PA regulatory threshold concentrations have been requested by the authorities. Therefore, a highly sensitive and reproducible UPLC TOF MS method for the quantification of the PAs senkirkine, senecionine, seneciphylline, senecionine-N-oxide and seneciphylline-N-oxide in a CO2-extract of Petasites hybridus leaves (Ze 339) has been developed. The limit of quantification (LOQ) was 2ppb for all PAs. Recovery at the LOQ was between 88.9 and 141.9%, the repeatability precision between 3.5 and 13.6%. Linearity of the five PAs showed correlation coefficients between 0.9995 and 0.9998 and coefficients of variation between 7.44 and 8.56%. A working range between 2 ppb and 200 ppb could be fixed. In the tested batches of the P. hybridus extract Ze 339, the absence of PAs could be demonstrated. In conclusion, this assay allows to determine trace PA concentrations in P. hybridus extract Ze 339, making it suitable for analytical PA monitoring in accordance with regulatory requirements.

  13. Monitoring sea lamprey pheromones and their degradation using rapid stream-side extraction coupled with UPLC-MS/MS

    USGS Publications Warehouse

    Wang, Huiyong; Johnson, Nicholas; Bernardy, Jeffrey; Hubert, Terry; Li, Weiming

    2013-01-01

    Pheromones guide adult sea lamprey (Petromyzon marinus) to suitable spawning streams and mates, and therefore, when quantified, can be used to assess population size and guide management. Here, we present an efficient sample preparation method where 100 mL of river water was spiked with deuterated pheromone as an internal standard and underwent rapid field-based SPE and elution in the field. The combination of field extraction with laboratory UPLC-MS/MS reduced the sample consumption from 1 to 0.1 L, decreased the sample process time from more than 1 h to 10 min, and increased the precision and accuracy. The sensitivity was improved more than one order of magnitude compared with the previous method. The influences of experimental conditions were assessed to optimize the separation and peak shapes. The analytical method has been validated by studies of stability, selectivity, precision, and linearity and by the determination of the limits of detection and quantification. The method was used to quantify pheromone concentration from five streams tributary to Lake Ontario and to estimate that the environmental half-life of 3kPZS is about 26 h.

  14. Immunoadjuvant activity, toxicity assays, and determination by UPLC/Q-TOF-MS of triterpenic saponins from Chenopodium quinoa seeds.

    PubMed

    Verza, Simone G; Silveira, Fernando; Cibulski, Samuel; Kaiser, Samuel; Ferreira, Fernando; Gosmann, Grace; Roehe, Paulo M; Ortega, George G

    2012-03-28

    The adjuvant activity of Chenopodium quinoa (quinoa) saponins on the humoral and cellular immune responses of mice subcutaneously immunized with ovalbumin (OVA) was evaluated. Two quinoa saponin fractions were obtained, FQ70 and FQ90, and 10 saponins were determined by UPLC/Q-TOF-MS. Mice were immunized subcutaneously with OVA alone or adjuvanted with Quil A (adjuvant control), FQ70, or FQ90. FQ70 and FQ90 significantly enhanced the amount of anti-OVA-specific antibodies in serum (IgG, IgG1, and IgG2b) in immunized mice. The adjuvant effect of FQ70 was significantly greater than that of FQ90. However, delayed type hypersensitivity responses were higher in mice immunized with OVA adjuvanted with FQ90 than mice treated with FQ70. Concanavalin A (Con A)-, lipopolysaccharide-, and OVA-stimulated splenocyte proliferation were measured, and FQ90 significantly enhanced the Con A-induced splenocyte proliferation. The results suggested that the two quinoa saponin fractions enhanced significantly the production of humoral and cellular immune responses to OVA in mice.

  15. Serum Pharmacochemistry Analysis Using UPLC-Q-TOF/MS after Oral Administration to Rats of Shenfu Decoction

    PubMed Central

    He, Jia-le; Zhao, Jia-wei; Ma, Zeng-chun; Wang, Yu-guang; Liang, Qian-de; Tan, Hong-ling; Xiao, Cheng-rong; Tang, Xiang-lin; Gao, Yue

    2015-01-01

    The purpose of this study was to study the serum pharmacochemistry of SFD as well as the material basis through analyzing the constituents absorbed in blood. The SFD was orally administrated to Wistar rats at 20 g·kg−1, and Ultra Performance Liquid Chromatography (UPLC) fingerprints of SFD were created. Serum samples were collected for analysis, and further data processing used MarkerLynx XS software. 19 ginsenosides and 16 alkaloids were detected in SFD. The absorption of alkaloids (mainly monoester diterpenoid alkaloids) increased when Aconitum carmichaeli Debx. was combined with Panax ginseng, while the ginsenosides remained stable. Diester diterpenoid alkaloids were not present in the serum samples. A suitable serum pharmacochemistry method was successfully established to study pharmacological effects and potential improvements in formulation. This may also be useful for toxicity reduction. We suspect that the increased absorption of the monoester diterpenoid alkaloids from the mixture of Panax and Radix, compared to the Panax only extract, may be the reason for the combination of the two herbs in popular medicine formulas in China. PMID:26273317

  16. Global Profiling of Metabolite and Lipid Soluble Microbial Products in Anaerobic Wastewater Reactor Supernatant Using UPLC-MS(E).

    PubMed

    Tipthara, Phornpimon; Kunacheva, Chinagarn; Soh, Yan Ni Annie; Wong, Stephen C C; Pin, Ng Sean; Stuckey, David C; Boehm, Bernhard O

    2017-02-03

    Identification of soluble microbial products (SMPs) released during bacterial metabolism in mixed cultures in bioreactors is essential to understanding fundamental mechanisms of their biological production. SMPs constitute one of the main foulants (together with colloids and bacterial flocs) in membrane bioreactors widely used to treat and ultimately recycle wastewater. More importantly, the composition and origin of potentially toxic, carcinogenic, or mutagenic SMPs in renewable/reused water supplies must be determined and controlled. Certain classes of SMPs have previously been studied by GC-MS, LC-MS, and MALDI-ToF MS; however, a more comprehensive LC-MS-based method for SMP identification is currently lacking. Here we develop a UPLC-MS approach to profile and identify metabolite SMPs in the supernatant of an anaerobic batch bioreactor. The small biomolecules were extracted into two fractions based on their polarity, and separate methods were then used for the polar and nonpolar metabolites in the aqueous and lipid fractions, respectively. SMPs that increased in the supernatant after feed addition were identified primarily as phospholipids, ceramides, with cardiolipins in the highest relative abundance, and these lipids have not been previously reported in wastewater effluent.

  17. A Fast One Step Extraction and UPLC-MS/MS Analysis for E2/D2 Series Prostaglandins and Isoprostanes

    PubMed Central

    Brose, Stephen A.; Baker, Andrew G.; Golovko, Mikhail Y.

    2013-01-01

    Prostaglandins (PG) and isoprostanes (iso-PG) may be derived through cyclooxygenase or free radical pathways and are important signaling molecules that are also robust biomarkers of oxidative stress. Their quantification is important for understanding many biological processes where PG, iso-PG, or oxidative stress are involved. One of the common methods for PG and iso-PG quantifications is LC-MS/MS that allows a highly selective, sensitive, simultaneous analysis for prostanoids without derivatization. However, the currently used LC-MS/MS methods require a multi-step extraction and a long (within an hour) LC separation to achieve simultaneous separation and analysis of the major iso-PG. The developed and validated for brain tissue analysis one-step extraction protocol and UPLC-MS/MS method significantly increases the recovery of the PG extraction up to 95%, and allows for a much faster (within 4 min) major iso-PGE2 and -PGD2 separation with 5 times narrower chromatographic peaks as compared to previously used methods. In addition, it decreases the time and cost of analysis due to one-step extraction approach performed in disposable centrifuge tubes. All together, this significantly increases the sensitivity, and the time and cost efficiency of the PG and iso-PG analysis. PMID:23400687

  18. Determination of microcystin-LR in drinking water using UPLC tandem mass spectrometry-matrix effects and measurement.

    PubMed

    Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis

    2011-10-01

    A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.

  19. Metabolomic Analysis of Diet-Induced Type 2 Diabetes Using UPLC/MS Integrated with Pattern Recognition Approach

    PubMed Central

    Sun, Hui; Zhang, Shuxiang; Zhang, Aihua; Yan, Guangli; Wu, Xiuhong; Han, Ying; Wang, Xijun

    2014-01-01

    Metabolomics represents an emerging discipline concerned with comprehensive assessment of small molecule endogenous metabolites in biological systems and provides a powerful approach insight into the mechanisms of diseases. Type 2 diabetes (T2D), called the burden of the 21st century, is growing with an epidemic rate. However, its precise molecular mechanism has not been comprehensively explored. In this study, we applied urinary metabolomics based on the UPLC/MS integrated with pattern recognition approaches to discover differentiating metabolites, to characterize and explore metabolic pathway disruption in an experimental model for high-fat-diet induced T2D. Six differentiating urinary metabolites were found in the negative mode, and two (2-(4-hydroxy-3-methoxy-phenyl) acetaldehyde sulfate, 2-phenylethanol glucuronide) of which were identified involving the key metabolic pathways linked to pentose and glucuronate interconversions, starch, sucrose metabolism and tyrosine metabolism. Our study provides new insight into pathophysiologic mechanisms and may enhance the understanding of T2D pathogenesis. PMID:24671089

  20. Development of an UPLC-MS/MS method for the determination of antibiotic ertapenem on dried blood spots.

    PubMed

    la Marca, Giancarlo; Giocaliere, Elisa; Villanelli, Fabio; Malvagia, Sabrina; Funghini, Silvia; Ombrone, Daniela; Filippi, Luca; De Gaudio, Marina; De Martino, Maurizio; Galli, Luisa

    2012-03-05

    Ertapenem (Invanz) is a newly developed carbapenem β-lactam antimicrobial agent. The drug usage in pediatric age needs an accurate drug monitoring for effective patient management. The aim of this study was to evaluate the use of dried blood spot (DBS) specimens to measure ertapenem concentration during treatment. The analysis was performed by UPLC-MS/MS operating in multiple reaction monitoring (MRM) mode. The calibration curve in matrix was linear in the concentration range of 0.5-100 mg/L with correlation coefficient value higher than 0.997. Performance parameters of this method like lower limit of detection (LLOD, 0.2 mg/L), lower limit of quantification (LLOQ, 0.5 mg/L), matrix effect (20%), intra- and inter-day imprecision (CV within than 15%) and accuracy (between 94 and 155%) of drug concentrations have been evaluated. The drug stability at different temperatures was tested for one month, to evaluate the risks of sample delivery at different climatic conditions. The reported method allows now ertapenem analysis and offers many advantages for patients including the possibility of collecting samples at home. This new assay is both precise and accurate and is especially suitable for therapeutic drug monitoring and pharmacokinetic studies in neonates in whom obtaining larger blood samples is not convenient or possible.

  1. Food Fingerprinting: Metabolomic Approaches for Geographical Origin Discrimination of Hazelnuts (Corylus avellana) by UPLC-QTOF-MS.

    PubMed

    Klockmann, Sven; Reiner, Eva; Bachmann, René; Hackl, Thomas; Fischer, Markus

    2016-12-07

    Ultraperformance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) was used for geographical origin discrimination of hazelnuts (Corylus avellana L.). Four different LC-MS methods for polar and nonpolar metabolites were evaluated with regard to best discrimination abilities. The most suitable method was used for analysis of 196 authentic samples from harvest years 2014 and 2015 (Germany, France, Italy, Turkey, Georgia), selecting and identifying 20 key metabolites with significant differences in abundancy (5 phosphatidylcholines, 3 phosphatidylethanolamines, 4 diacylglycerols, 7 triacylglycerols, and γ-tocopherol). Classification models using soft independent modeling of class analogy (SIMCA), linear discriminant analysis based on principal component analysis (PCA-LDA), support vector machine classification (SVM), and a customized statistical model based on confidence intervals of selected metabolite levels were created, yielding 99.5% training accuracy at its best by combining SVM and SIMCA. Forty nonauthentic hazelnut samples were subsequently used to estimate as realistically as possible the prediction capacity of the models.

  2. Simultaneous quantitation of sphingoid bases by UPLC-ESI-MS/MS with identical (13)C-encoded internal standards.

    PubMed

    Mirzaian, M; Wisse, P; Ferraz, M J; Marques, A R A; Gaspar, P; Oussoren, S V; Kytidou, K; Codée, J D C; van der Marel, G; Overkleeft, H S; Aerts, J M

    2017-03-01

    Free sphingoid bases (lysosphingolipids) of primary storage sphingolipids are increased in tissues and plasma of several sphingolipidoses. As shown earlier by us, sphingoid bases can be accurately quantified using UPLC-ESI-MS/MS, particularly in combination with identical (13)C-encoded internal standards. The feasibility of simultaneous quantitation of sphingoid bases in plasma specimens spiked with a mixture of such standards is here described. The sensitivity and linearity of detection is excellent for all examined sphingoid bases (sphingosine, sphinganine, hexosyl-sphingosine (glucosylsphingosine), hexosyl2-sphingosine (lactosylsphingosine), hexosyl3-sphingosine (globotriaosylsphingosine), phosphorylcholine-sphingosine) in the relevant concentration range and the measurements show very acceptable intra- and inter-assay variation (<10% average). Plasma samples of a series of male and female Gaucher Disease and Fabry Disease patients were analyzed with the multiplex assay. The obtained data compare well to those earlier determined for plasma globotriaosylsphingosine and glucosylsphingosine in GD and FD patients. The same approach can be also applied to measure sphingolipids in the same sample. Following extraction of sphingolipids from the same sample these can be converted to sphingoid bases by microwave exposure and subsequently quantified using (13)C-encoded internal standards.

  3. Development and validation of an ultra-high-performance liquid chromatography tandem mass spectrometric method for the simultaneous determination of free and conjugated Alternaria toxins in cereal-based foodstuffs.

    PubMed

    Walravens, Jeroen; Mikula, Hannes; Rychlik, Michael; Asam, Stefan; Ediage, Emmanuel Njumbe; Di Mavungu, José Diana; Van Landschoot, Anita; Vanhaecke, Lynn; De Saeger, Sarah

    2014-10-31

    A UPLC-ESI(+/-)-MS/MS method for the simultaneous determination of free (alternariol, alternariol monomethyl ether, altenuene, tenuazonic acid, tentoxin, altertoxin-I) and conjugated (sulfates and glucosides of alternariol and alternariol monomethyl ether) Alternaria toxins in cereals and cereal products (rice, oat flakes and barley) was developed. Optimization of the sample preparation and extraction methodology was achieved through experimental design, using full factorial design for extraction solvent composition optimization and fractional factorial design to identify the critical factors in the sample preparation protocol, which were in turn subjected to optimization. Final extracts were analysed using an Waters Acquity UPLC system coupled to a Quattro Premier XE mass spectrometer equipped with an electrospray interface operated in both positive and negative ionization mode. Chromatographic separation was achieved using an Acquity UPLC HSS T3 column, and the applied gradient elution programme allowed for the simultaneous determination of 10 Alternaria toxins in a one-step chromatographic run with a total run time of only 7min. Subsequently, the method, applying isotopically labelled internal standards ([(2)H4]-alternariol monomethyl ether and [(13)C6,(15)N]-tenuazonic acid), was validated for several parameters such as linearity, apparent recovery, limit of detection, limit of quantification, precision, measurement uncertainty and specificity (in agreement with the criteria mentioned in Commission Regulation No. 401/2006/EC and Commission Decision No. 2002/657/EC). During validation, quality of the bioanalytical data was improved by counteracting the observed heteroscedasticity through the application of weighted least squares linear regression (WLSLR). Finally, 24 commercially available cereal-based foodstuffs were subjected to analysis, revealing the presence of tenuazonic acid in both rice and oat flake samples (

  4. Design procedures for fiber composite structural components: Rods, columns and beam columns

    NASA Technical Reports Server (NTRS)

    Chamis, C. C.

    1983-01-01

    Step by step procedures are described which are used to design structural components (rods, columns, and beam columns) subjected to steady state mechanical loads and hydrothermal environments. Illustrative examples are presented for structural components designed for static tensile and compressive loads, and fatigue as well as for moisture and temperature effects. Each example is set up as a sample design illustrating the detailed steps that are used to design similar components.

  5. How to select equivalent and complimentary reversed phase liquid chromatography columns from column characterization databases.

    PubMed

    Borges, Endler M

    2014-01-07

    Three RP-LC column characterization protocols [Tanaka et al. (1989), Snyder et al. (PQRI, 2002), and NIST SRM 870 (2000)] were evaluated using both Euclidian distance and Principal Components Analysis to evaluate effectiveness at identifying equivalent columns. These databases utilize specific chromatographic properties such as hydrophobicity, hydrogen bonding, shape/steric selectivity, and ion exchange capacity of stationary phases. The chromatographic parameters of each test were shown to be uncorrelated. Despite this, the three protocols were equally successful in identifying similar and/or dissimilar stationary phases. The veracity of the results has been supported by some real life pharmaceutical separations. The use of Principal Component Analysis to identify similar/dissimilar phases appears to have some limitations in terms of loss of information. In contrast, the use of Euclidian distances is a much more convenient and reliable approach. The use of auto scaled data is favoured over the use of weighted factors as the former data transformation is less affected by the addition or removal of columns from the database. The use of these free databases and their corresponding software tools shown to be valid for identifying similar columns with equivalent chromatographic selectivity and retention as a "backup column". In addition, dissimilar columns with complimentary chromatographic selectivity can be identified for method development screening strategies.

  6. Modeling of Crystalline Silicotitanate Ion Exchange Columns

    SciTech Connect

    Walker, D.D.

    1999-03-09

    Non-elutable ion exchange is being considered as a potential replacement for the In-Tank Precipitation process for removing cesium from Savannah River Site (SRS) radioactive waste. Crystalline silicotitanate (CST) particles are the reference ion exchange medium for the process. A major factor in the construction cost of this process is the size of the ion exchange column required to meet product specifications for decontaminated waste. To validate SRS column sizing calculations, SRS subcontracted two reknowned experts in this field to perform similar calculations: Professor R. G. Anthony, Department of Chemical Engineering, Texas A&038;M University, and Professor S. W. Wang, Department of Chemical Engineering, Purdue University. The appendices of this document contain reports from the two subcontractors. Definition of the design problem came through several meetings and conference calls between the participants and SRS personnel over the past few months. This document summarizes the problem definition and results from the two reports.

  7. Solar Cycle Variability in Tropical Column Ozone

    NASA Astrophysics Data System (ADS)

    Yung, Y. L.; Liang, M.; Li, K.; Jiang, X.; Camp, C. D.

    2011-12-01

    Using an empirical orthogonal function (EOF) method [Camp et al., 2003], we analyzed the Merged Ozone Data (MOD) set from late 1978 to the present. The decadal variability of column ozone in the tropics follows that of the sun over three solar cycles. The peak-to-peak amplitude is about 10 DU (Dobson Units), consistent with the conclusion of Camp et al. [2003], who analyzed the MOD data up to and including 2000. Previous attempts to model the amplitude of the observed solar cycle in ozone were unsuccessful, as models tended to underestimate the solar cycle effect. Using the Whole Atmosphere Community Climate Model (WACCM) in combination with the latest satellite measurements of solar variability in the UV [McClintock et al., 2005; Harder et al., 2009], we correctly simulate the solar cycle signal in the total column ozone for the first time. The implications for solar forcing on middle atmosphere chemistry are discussed.

  8. LC-MS/MS method using unbonded silica column and aqueous/methanol mobile phase for the simultaneous quantification of a drug candidate and co-administered metformin in rat plasma.

    PubMed

    Discenza, Lorell; D'Arienzo, Celia; Olah, Timothy; Jemal, Mohammed

    2010-06-01

    BMS-754807 and metformin were co-administered in drug discovery studies which required the quantitation of both compounds in plasma. Since the two compounds are chemically and structurally dissimilar, developing a single bioanalytical method presented a number of chromatographic challenges including the achievement of appropriate retention times and peak shapes on a single analytical column. To address this chromatographic challenge, we investigated different LC columns under different gradient elution schemes using aqueous/organic mobile phases. Using unbonded silica column and aqueous/methanol mobile phase, we were able to obtain robust and well-resolving chromatographic conditions to support the development and implementation of a single LC-MS/MS bioanalytical method. The use of sub-2 micron particle sizes and a high flow rate, which are attainable with UPLC systems, enhanced the method. The method performance evaluation showed that the method easily met the normally used acceptance criteria for bioanalytical methods, namely a deviation of +/-15% from the nominal concentration except at lower limit of quantitation (LLOQ), where +/-20% is accepted. The reported LLOQ of 7.8 ng/ml, for both BMS-754807 and metformin, was adequate to support the pharmacokinetic studies.

  9. Column flotation of coal with fluorosurfactants

    SciTech Connect

    Not Available

    1989-10-01

    Laboratory tests were carried out by the US Bureau of Mines, Salt Lake City Research Center to evaluate the potential of column flotation technology, coupled with novel fluorosurfactant collectors, for the selective flotation of fine coal from pyritic sulfur and mineral matter. The results on flotation feeds of both {minus}100 and {minus}400 mesh Middle Kittaning seam coal samples are presented. 4 refs., 23 figs., 9 tabs.

  10. Plant practices in fine coal column flotation

    SciTech Connect

    Davis, V.L. Jr.; Bethell, P.J.; Stanley, F.L.; Luttrell, G.H.

    1995-10-01

    Five 3 m (10 ft) diameter Microcel{trademark} flotation columns were installed at Clinchfield Coal Company`s Middle Fork preparation facility in order to reduce product ash and increase recovery and plant capacity. The Middle Fork facility is utilized for the recovery of fine coal from a feed stream that consists primarily of 1.5 mm x 0 material. The columns replaced conventional flotation cells for the treatment of the minus 150 {micro}m fraction while spirals are used to upgrade the plus 150 {micro}m material in the plant feed. The addition of the column flotation circuit resulted in an increase in plant capacity in excess of 20 percent while reducing the flotation product ash content by approximately 7 percentage points. Flotation circuit combustible recovery wa increased by 17 percentage points. This paper discusses circuit design, commissioning, and sparging system design. Circuit instrumentation, level control, reagent system control, performance comparisons with conventional flotation, and general operating procedures are also discussed.

  11. Modular evolution of the Cetacean vertebral column.

    PubMed

    Buchholtz, Emily A

    2007-01-01

    Modular theory predicts that hierarchical developmental processes generate hierarchical phenotypic units that are capable of independent modification. The vertebral column is an overtly modular structure, and its rapid phenotypic transformation in cetacean evolution provides a case study for modularity. Terrestrial mammals have five morphologically discrete vertebral series that are now known to be coincident with Hox gene expression patterns. Here, I present the hypothesis that in living Carnivora and Artiodactyla, and by inference in the terrestrial ancestors of whales, the series are themselves components of larger precaudal and caudal modular units. Column morphology in a series of fossil and living whales is used to predict the type and sequence of developmental changes responsible for modification of that ancestral pattern. Developmental innovations inferred include independent meristic additions to the precaudal column in basal archaeocetes and basilosaurids, stepwise homeotic reduction of the sacral series in protocetids, and dissociation of the caudal series into anterior tail and fluke subunits in basilosaurids. The most dramatic change was the novel association of lumbar and anterior caudal vertebrae in a module that crosses the precaudal/caudal boundary. This large unit is defined by shared patterns of vertebral morphology, count, and size in all living whales (Neoceti).

  12. Employing anatomical knowledge in vertebral column labeling

    NASA Astrophysics Data System (ADS)

    Yao, Jianhua; Summers, Ronald M.

    2009-02-01

    The spinal column constitutes the central axis of human torso and is often used by radiologists to reference the location of organs in the chest and abdomen. However, visually identifying and labeling vertebrae is not trivial and can be timeconsuming. This paper presents an approach to automatically label vertebrae based on two pieces of anatomical knowledge: one vertebra has at most two attached ribs, and ribs are attached only to thoracic vertebrae. The spinal column is first extracted by a hybrid method using the watershed algorithm, directed acyclic graph search and a four-part vertebra model. Then curved reformations in sagittal and coronal directions are computed and aggregated intensity profiles along the spinal cord are analyzed to partition the spinal column into vertebrae. After that, candidates for rib bones are detected using features such as location, orientation, shape, size and density. Then a correspondence matrix is established to match ribs and vertebrae. The last vertebra (from thoracic to lumbar) with attached ribs is identified and labeled as T12. The rest of vertebrae are labeled accordingly. The method was tested on 50 CT scans and successfully labeled 48 of them. The two failed cases were mainly due to rudimentary ribs.

  13. Quantitative determination and evaluation of Paris polyphylla var. yunnanensis with different harvesting times using UPLC-UV-MS and FT-IR spectroscopy in combination with partial least squares discriminant analysis.

    PubMed

    Yang, Yuan-Gui; Zhang, Ji; Zhao, Yan-Li; Zhang, Jin-Yu; Wang, Yuan-Zhong

    2016-12-09

    A rapid method was developed and validated by ultra-performance liquid chromatography-triple quadrupole mass spectroscopy with ultraviolet detection (UPLC-UV-MS) for simultaneous determination of paris saponin I, paris saponin II, paris saponin VI and paris saponin VII. Partial least squares discriminant analysis (PLS-DA) based on UPLC and Fourier transform infrared (FT-IR) spectroscopy was employed to evaluate Paris polyphylla var. yunnanensis (PPY) at different harvesting times. Quantitative determination implied that the various contents of bioactive compounds with different harvesting times may lead to different pharmacological effects; the average content of total saponins for PPY harvested at 8 years was higher than that from other samples. The PLS-DA of FT-IR spectra had a better performance than that of UPLC for discrimination of PPY from different harvesting times.

  14. Comparison of monolithic silica and polymethacrylate capillary columns for LC.

    PubMed

    Moravcová, Dana; Jandera, Pavel; Urban, Jiri; Planeta, Josef

    2004-07-01

    Organic polymer monolithic capillary columns were prepared in fused-silica capillaries by radical co-polymerization of ethylene dimethacrylate and butyl methacrylate monomers with azobisisobutyronitrile as initiator of the polymerization reaction in the presence of various amounts of porogenic solvent mixtures and different concentration ratios of monomers and 1-propanol, 1,4-butanediol, and water. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica-based particulate and monolithic capillary and analytical HPLC columns. The tests included the determination of H-u curves, column permeabilities, pore distribution by inversed-SEC measurements, methylene and polar selectivities, and polar interactions with naphthalenesulphonic acid test samples. Organic polymer monolithic capillary columns show similar retention behaviour to chemically bonded alkyl silica columns for compounds with different polarities characterized by interaction indices, Ix, but have lower methylene selectivities and do not show polar interactions with sulphonic acids. The commercial capillary and analytical silica gel-based monolithic columns showed similar selectivities and provided symmetrical peaks, indicating no significant surface heterogeneities. To allow accurate characterization of the properties of capillary monolithic columns, the experimental data should be corrected for extra-column contributions. With 0.3 mm ID capillary columns, corrections for extra-column volume contributions are sufficient, but to obtain true information on the efficiency of 0.1 mm ID capillary columns, the experimental bandwidths should be corrected for extra-column contributions to peak broadening.

  15. Identification of a ligand for tumor necrosis factor receptor from Chinese herbs by combination of surface plasmon resonance biosensor and UPLC-MS.

    PubMed

    Cao, Yan; Li, Ying-Hua; Lv, Di-Ya; Chen, Xiao-Fei; Chen, Lang-Dong; Zhu, Zhen-Yu; Chai, Yi-Feng; Zhang, Jun-Ping

    2016-07-01

    Identification of bioactive compounds directly from complex herbal extracts is a key issue in the study of Chinese herbs. The present study describes the establishment and application of a sensitive, efficient, and convenient method based on surface plasmon resonance (SPR) biosensors for screening active ingredients targeting tumor necrosis factor receptor type 1 (TNF-R1) from Chinese herbs. Concentration-adjusted herbal extracts were subjected to SPR binding assay, and a remarkable response signal was observed in Rheum officinale extract. Then, the TNF-R1-bound ingredients were recovered, enriched, and analyzed by UPLC-QTOF/MS. As a result, physcion-8-O-β-D-monoglucoside (PMG) was identified as a bioactive compound, and the affinity constant of PMG to TNF-R1 was determined by SPR affinity analysis (K D  = 376 nM). Pharmacological assays revealed that PMG inhibited TNF-α-induced cytotoxicity and apoptosis in L929 cells via TNF-R1. Although PMG was a trace component in the chemical constituents of the R. officinale extract, it had considerable anti-inflammatory activities. It was found for the first time that PMG was a ligand for TNF receptor from herbal medicines. The proposed SPR-based screening method may prove to be an effective solution to analyzing bioactive components of Chinese herbs and other complex drug systems. Graphical abstract Scheme of the method based on SPR biosensor for screening and recovering active ingredients from complex herbal extracts and UPLC-MS for identifying them. Scheme of the method based on SPR biosensor for screening and recovering active ingredients from complex herbal extracts and UPLC-MS for identifying them.

  16. Using UHPLC Q-Trap/MS as a complementary technique to in-depth mine UPLC Q-TOF/MS data for identifying modified nucleosides in urine.

    PubMed

    Lu, Zhiwei; Wang, Qing; Wang, Meiling; Fu, Shuang; Zhang, Qingqing; Zhang, Zhixin; Zhao, Huizhen; Liu, Yuehong; Huang, Zhenhai; Xie, Ziye; Yu, Honghong; Gao, Xiaoyan

    2017-03-12

    Modified nucleosides, metabolites of RNA, are potential biomarkers of cancer before the appearance of morphological abnormalities. It is of great significance to comprehensively detect and identify nucleosides in human urine for discovery of cancer biomarkers. However, the lower abundance, the greater polarity and the matrix effects make it difficult to detect urinary nucleosides. In this paper, an integrated method consisted of sample preparation followed by ultraperformance liquid chromatography quadrupole time-of-flight mass spectrometry (UPLC Q-TOF/MS) detection and primary identification, then ultra-high performance liquid chromatography coupled with hybrid triple quadrupole linear ion trap mass spectrometer (UHPLC Q-Trap/MS) further identification and validation were introduced. Firstly, to enrich the nucleosides and eliminate the urine matrix effects, different sorbent materials of solid phase extraction (SPE) and the elution conditions were screened. Secondly, UPLC Q-TOF/MS was used to acquire mass data in MS(E) mode. The structural formulas of nucleosides in urine sample were primarily identified according to retention time, accurate mass precursor ions and fragment ions from in-house database and online database. Thirdly, the preliminary identified nucleoside structures lacking of characteristic fragment ions were verified by UHPLC Q-Trap/MS in multiple reaction monitoring trigger enhanced product ion scan (MRM-EPI) and neutral loss scan (NL). At last, phenylboronic acid (PBA)-based SPE was utilized due to its higher MS signal and weaker matrix effects under optimized extraction conditions. Fifty-five nucleosides were primarily identified by UPLC Q-TOF/MS, among which 50 nucleosides were confirmed by UHPLC Q-Trap/MS. Five nucleosides, namely 4',5'-didehydro-5'-deoxyadenosine, 4',5'-didehydro-5'-deoxyinosine, isonicotinamide riboside, peroxywybutosine and hydroxywybutosine, were found from urine for the first time. The results will expand the Human

  17. Exploratory urinary metabolic biomarkers and pathways using UPLC-Q-TOF-HDMS coupled with pattern recognition approach.

    PubMed

    Zhang, Aihua; Sun, Hui; Han, Ying; Yuan, Ye; Wang, Ping; Song, Gaochen; Yuan, Xiaoxia; Zhang, Miao; Xie, Ning; Wang, Xijun

    2012-09-21

    Metabolomics represents an emerging and powerful discipline concerned with the comprehensive analysis of small molecules and provides a powerful approach to discover biomarkers in biological systems. Recent development of biomarkers for diagnosis and therapeutic monitoring of liver-stagnation and spleen-deficiency syndrome (LSS)-type disease remains challenging. This study was undertaken to discover novel potential biomarkers for the non-invasive early diagnosis of human LSS. Urine samples which are potentially a rich source of metabolites were collected from patients with LSS, together with healthy control samples. Metabolite profiling was performed by ultra-performance liquid-chromatography/electrospray-ionization synapt high-definition mass spectrometry (UPLC-Q-TOF-HDMS) in conjunction with multivariate data analysis and ingenuity pathway analysis that were used to select the metabolites to be used for the non-invasive diagnosis of LSS. Twelve urinary differential metabolites contributing to the complete separation of LSS patients from matched healthy controls were identified involving several key metabolic pathways such as pentose and glucuronate interconversions, ascorbate, aldarate, cysteine, methionine, tyrosine, tryptophan, amino sugar and nucleotide sugar metabolism. More importantly, of the 12 differential metabolites, 4 metabolite markers, prolylhydroxyproline, L-homocystine, 2-octenoylcarnitine and α-N-phenylacetyl-L-glutamine, were effective for the diagnosis of human LSS, with an achieved sensitivity of 93.0%. These results demonstrate that robust metabolomics has the potential as a non-invasive strategy and promising screening tool to evaluate the potential of these metabolites in the early diagnosis of LSS patients and provides new insight into pathophysiological mechanisms.

  18. Seasonal and Species Variation of the Hepatotoxin Indospicine in Australian Indigofera Legumes As Measured by UPLC-MS/MS.

    PubMed

    Tan, Eddie T T; Materne, Christopher M; Silcock, Richard G; D'Arcy, Bruce R; Al Jassim, Rafat; Fletcher, Mary T

    2016-08-31

    Livestock industries have maintained a keen interest in pasture legumes because of the high protein content and nutritive value. Leguminous Indigofera plant species have been considered as having high feeding values to be utilized as pasture, but the occurrence of the toxic constituent indospicine in some species has restricted this utility. Indospicine has caused both primary and secondary hepatotoxicosis and also reproductive losses, but has only previously been determined in a small number of Indigofera species. This paper validates a high-throughput ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method to determine the indospicine content of various Indigofera species found in Australian pasture. Twelve species of Indigofera together with Indigastrum parviflorum plants were collected and analyzed. Of the 84 samples analyzed, *I. spicata (the asterisk indicates a naturalized species) contained the highest indospicine level (1003 ± 328 mg/kg DM, n = 4) followed by I. linnaei (755 ± 490 mg/kg DM, n = 51). Indospicine was not detected in 9 of the remaining 11 species and at only low levels (<10 mg/kg DM) in 2 of 8 I. colutea specimens and in 1 of 5 I. linifolia specimens. Indospicine concentrations were below quantitation levels for other Indigofera spp. (I. adesmiifolia, I. georgei, I. hirsuta, I. leucotricha, *I. oblongifolia, I. australis, and I. trita) and Indigastrum parviflorum. One of the more significant findings to emerge from this study is that the indospicine content of I. linnaei is highly variable (from 159 to 2128 mg/kg DM, n = 51) and differs across both regions and seasons. Its first regrowth after spring rain has a higher (p < 0.01) indospicine content than growth following more substantial summer rain. The species collected include the predominant Indigofera in Australia pasture, and of these, only *I. spicata and I. linnaei contain high enough levels of indospicine to pose a potential toxic threat to grazing

  19. Development and validation of a UPLC-MS/MS method to monitor cephapirin excretion in dairy cows following intramammary infusion.

    PubMed

    Ray, Partha; Knowlton, Katharine F; Shang, Chao; Xia, Kang

    2014-01-01

    Cephapirin, a cephalosporin antibiotic, is used by the majority of dairy farms in the US. Fecal and urinary excretion of cephapirin could introduce this compound into the environment when manure is land applied as fertilizer, and may cause development of bacterial resistance to antibiotics critical for human health. The environmental loading of cephapirin by the livestock industry remains un-assessed, largely due to a lack of appropriate analytical methods. Therefore, this study aimed to develop and validate a cephapirin quantification method to capture the temporal pattern of cephapirin excretion in dairy cows following intramammary infusion. The method includes an extraction with phosphate buffer and methanol, solid-phase extraction (SPE) clean-up, and quantification using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The LOQ values of the developed method were 4.02 µg kg(-1) and 0.96 µg L(-1) for feces and urine, respectively. This robust method recovered >60% and >80% cephapirin from spiked blank fecal and urine samples, respectively, with acceptable intra- and inter-day variation (<10%). Using this method, we detected trace amounts (µg kg(-1)) of cephapirin in dairy cow feces, and cephapirin in urine was detected at very high concentrations (133 to 480 µg L(-1)). Cephapirin was primarily excreted via urine and its urinary excretion was influenced by day (P = 0.03). Peak excretion (2.69 mg) was on day 1 following intramammary infusion and decreased sharply thereafter (0.19, 0.19, 0.08, and 0.17 mg on day 2, 3, 4, and 5, respectively) reflecting a quadratic pattern of excretion (Quadratic: P = 0.03). The described method for quantification of cephapirin in bovine feces and urine is sensitive, accurate, and robust and allowed to monitor the pattern of cephapirin excretion in dairy cows. This data will help develop manure segregation and treatment methods to minimize the risk of antibiotic loading to the environment from dairy

  20. A Simple, Rapid Method for Determination of Melatonin in Plant Tissues by UPLC Coupled with High Resolution Orbitrap Mass Spectrometry

    PubMed Central

    Ye, Tiantian; Hao, Yan-Hong; Yu, Lei; Shi, Haitao; Reiter, Russel J.; Feng, Yu-Qi

    2017-01-01

    Melatonin (MLT) was involved in regulating various stages of plant growth and development. However, due to the low concentration and complex matrixes of plant, the analysis of MLT is a challenging task. In this study, we developed a rapid and efficient method with simplified sample preparation by employing UPLC coupled with a high resolution Orbitrap mass spectrometry, and stable isotope-labeled MLT (MLT-d4) was first used as internal standard in the developed analytical method. In the developed method, we used one-step liquid–liquid extraction to purify the crude extracts both from shoot and root of rice for the analysis, which remarkably simplify the sample preparation process. The method exhibits high specificity and recovery yield (>96.4%). Good linearities were obtained for MLT ranging from 0.01 to 20 ng/ mL with determination coefficient (R2) of 0.9991. The limit of detection for MLT was 0.03 pg. Reproducibility of the method was evaluated by intra-day and inter-day measurements and the results showed that relative standard deviations were less than 7.2%. Moreover, MLT quantification was accomplished by using only 100 mg fresh plant tissues. Additionally, the established method was successfully applied to investigate the spatiotemporal distributions of MLT in rice under cadmium (Cd) stress condition. We found that the content of MLT in shoot and root of rice increased under Cd stress, suggesting that MLT would play a crucial role in modulating the responses to Cd stress in different plant tissues. PMID:28179912

  1. A comprehensive understanding of thioTEPA metabolism in the mouse using UPLC-ESI-QTOFMS-based metabolomics.

    PubMed

    Li, Fei; Patterson, Andrew D; Höfer, Constance C; Krausz, Kristopher W; Gonzalez, Frank J; Idle, Jeffrey R

    2011-04-15

    ThioTEPA, an alkylating agent with anti-tumor activity, has been used as an effective anticancer drug since the 1950s. However, a complete understanding of how its alkylating activity relates to clinical efficacy has not been achieved, the total urinary excretion of thioTEPA and its metabolites is not resolved, and the mechanism of formation of the potentially toxic metabolites S-carboxymethylcysteine (SCMC) and thiodiglycolic acid (TDGA) remains unclear. In this study, the metabolism of thioTEPA in a mouse model was comprehensively investigated using ultra-performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight mass spectrometry (UPLC-ESI-QTOFMS) based-metabolomics. The nine metabolites identified in mouse urine suggest that thioTEPA underwent ring-opening, N-dechloroethylation, and conjugation reactions in vivo. SCMC and TDGA, two downstream thioTEPA metabolites, were produced from thioTEPA from two novel metabolites 1,2,3-trichloroTEPA (VII) and dechloroethyltrichloroTEPA (VIII). SCMC and TDGA excretion were increased about 4-fold and 2-fold, respectively, in urine following the thioTEPA treatment. The main mouse metabolites of thioTEPA in vivo were TEPA (II), monochloroTEPA (III) and thioTEPA-mercapturate (IV). In addition, five thioTEPA metabolites were detected in serum and all shared similar disposition. Although thioTEPA has a unique chemical structure which is not maintained in the majority of its metabolites, metabolomic analysis of its biotransformation greatly contributed to the investigation of thioTEPA metabolism in vivo, and provides useful information to understand comprehensively the pharmacological activity and potential toxicity of thioTEPA in the clinic.

  2. Trace detection of the chlorohydrins of epoxidized soybean oil in foodstuffs by UPLC-ESI-MS/MS.

    PubMed

    Suman, Michele; De Dominicis, Emiliano; Commissati, Italo

    2010-09-01

    Epoxidized soybean oil (ESBO) is used as an authorized plasticizer and a stabilizer for plastic polymers such as poly(vinyl chloride) (PVC). Recently, however, there has been a concrete effort devoted to its substitution for other plasticizers such as polyadipates. ESBO is exploited particularly in food closure gaskets for metal lids used to seal glass jars and bottles. The closure gaskets form an airtight seal necessary to prevent microbiological contamination. Thus, there are potential uses for food sterilization and storage. Additionally, the main pathway of PVC degradation involves the elimination of HCl, which can react with the epoxy groups of ESBO to give mono-, polychlorohydrins and/or other cyclic derivatives. The European Food Safety Authority noted that not enough analytical and toxicological data exist to express a formal opinion on the significance for the health effects of such derivatives. At present in the scientific literature, there are only a few indicative results of direct measurements of ESBO derivatives and there are no official analytical methods available for the determination of chlorohydrins directly from foodstuffs. This study presents the first example of the analysis of commercial food sauces for the detection of ESBO-chlorohydrins (as methyl esters). The results are obtained by a dedicated development of an ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) method. Sample preparation was based on the following main steps: organic extraction, transesterification and solid-phase extraction clean up. In particular, four isomers for 18-E-OHCl chlorohydrin and eight isomers for 18-2OHCl chlorohydrin were separated and identified. Different food sauces samples closed in glass jars with twist-off caps were subjected to qualitative determination, which yielded positive results for 18-E-OHCl, whereas no traces of 18-2OHCl were found.

  3. Determination of ω-6 and ω-3 PUFA metabolites in human urine samples using UPLC/MS/MS.

    PubMed

    Sasaki, Ai; Fukuda, Hayato; Shiida, Narumi; Tanaka, Nobuaki; Furugen, Ayako; Ogura, Jiro; Shuto, Satoshi; Mano, Nariyasu; Yamaguchi, Hiroaki

    2015-02-01

    The ω-6 and ω-3 polyunsaturated fatty acids (PUFAs) such as arachidonic acid (AA), eicosapentaenoic acid (EPA), and docosahexaenoic acid (DHA) are the precursors of various bioactive lipid mediators including prostaglandins, thromboxanes, leukotrienes, hydroxyeicosatetraenoic acid, isoprostanes, lipoxins, and resolvins (Rvs). These lipid mediators play important roles in various physiological and pathological processes. The quantitative determination of PUFA metabolites seems necessary for disease research and for developing biomarkers. However, there is a paucity of analytical methods for the quantification of ω-6 and ω-3 PUFA metabolites—the specialized pro-resolving mediators (SPMs) present in the human urine. We developed a method for the quantification of ω-6 and ω-3 PUFA metabolites present in human urine using ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS). The developed method shows good linearity, with a correlation coefficient >0.99 for all of the analytes. The validation results indicate that our method is adequately reliable, accurate, and precise. The method was successfully used to examine urine samples obtained from 43 healthy volunteers. We could identify 20 PUFA metabolites, and this is the first report of the quantitative determination of RvD1, 17(R)-RvD1, 11-dehydro thromboxane B3, RvE2, and 5(S)-HETE in human urine. The urinary 8-iso PGF(2α) and PGE2 levels were significantly higher in the men smokers than in the men nonsmokers (p < 0.05). In this study, we developed an accurate, precise, and novel analytical method for estimating the ω-6 and ω-3 PUFA metabolites, and this is the first report that the SPMs derived from EPA and DHA are present in human urine.

  4. A validated UPLC-MS/MS method for the surveillance of ten aquatic biotoxins in European brackish and freshwater systems.

    PubMed

    Greer, Brett; McNamee, Sara E; Boots, Bas; Cimarelli, Lucia; Guillebault, Delphine; Helmi, Karim; Marcheggiani, Stefania; Panaiotov, Stefan; Breitenbach, Ulrich; Akçaalan, Reyhan; Medlin, Linda K; Kittler, Katrin; Elliott, Christopher T; Campbell, Katrina

    2016-05-01

    Over the past few decades, there has been an increased frequency and duration of cyanobacterial Harmful Algal Blooms (HABs) in freshwater systems globally. These can produce secondary metabolites called cyanotoxins, many of which are hepatotoxins, raising concerns about repeated exposure through ingestion of contaminated drinking water or food or through recreational activities such as bathing/swimming. An ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) multi-toxin method has been developed and validated for freshwater cyanotoxins; microcystins-LR, -YR, -RR, -LA, -LY and -LF, nodularin, cylindrospermopsin, anatoxin-a and the marine diatom toxin domoic acid. Separation was achieved in around 9min and dual SPE was incorporated providing detection limits of between 0.3 and 5.6ng/L of original sample. Intra- and inter-day precision analysis showed relative standard deviations (RSD) of 1.2-9.6% and 1.3-12.0% respectively. The method was applied to the analysis of aquatic samples (n=206) from six European countries. The main class detected were the hepatotoxins; microcystin-YR (n=22), cylindrospermopsin (n=25), microcystin-RR (n=17), microcystin-LR (n=12), microcystin-LY (n=1), microcystin-LF (n=1) and nodularin (n=5). For microcystins, the levels detected ranged from 0.001 to 1.51μg/L, with two samples showing combined levels above the guideline set by the WHO of 1μg/L for microcystin-LR. Several samples presented with multiple toxins indicating the potential for synergistic effects and possibly enhanced toxicity. This is the first published pan European survey of freshwater bodies for multiple biotoxins, including two identified for the first time; cylindrospermopsin in Ireland and nodularin in Germany, presenting further incentives for improved monitoring and development of strategies to mitigate human exposure.

  5. 19. Detail of builtup 5" x 13" column at fruit ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Detail of built-up 5" x 13" column at fruit and vegetable storage room; note ledger plates bolted to top of column - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  6. 20. Detail of 8" square solid wood column at fruit ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Detail of 8" square solid wood column at fruit and vegetable storage room; note ledger plates bolted to top of column - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  7. Method to fabricate silicon chromatographic column comprising fluid ports

    DOEpatents

    Manginell, Ronald P.; Frye-Mason, Gregory C.; Heller, Edwin J.; Adkins, Douglas R.

    2004-03-02

    A new method for fabricating a silicon chromatographic column comprising through-substrate fluid ports has been developed. This new method enables the fabrication of multi-layer interconnected stacks of silicon chromatographic columns.

  8. 6. HISTORIC AMERICAN BUILDINGS SURVEY, INTERIOR SHOWING ORIGINAL GRANITE COLUMNS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. HISTORIC AMERICAN BUILDINGS SURVEY, INTERIOR SHOWING ORIGINAL GRANITE COLUMNS AND COLUMN BRICKFACED AFTER THE GREAT FIRE 1904 - Old U.S. Appraisers Stores, Gay & Lombard Streets, Baltimore, Independent City, MD

  9. A Convenient Method for Comparison of Efficiency of Fractionating Columns.

    ERIC Educational Resources Information Center

    Higgins, Robert H.

    1990-01-01

    Presented is a method for demonstrating the use of various fractionating columns to resolve mixtures into individual components and to correlate the resolving powers of column packings to their "hold-up" volumes. Fractions were analyzed using refractive indices. (KR)

  10. 14. Detail view of columns, capitals and beams at south ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    14. Detail view of columns, capitals and beams at south end of north section of mill. Note the transition from deep pocket to shallow pocket column capitals. - Lowe Mill, Eighth Avenue, Southwest, Huntsville, Madison County, AL

  11. 3. Detail of beam splice and column capital on the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. Detail of beam splice and column capital on the second floor of the Cloth Room Building/Old Bleach House, Monadnock Mills. Beam and column edges are chamfered. - Monadnock Mills, 15 Water Street, Claremont, Sullivan County, NH

  12. CAR MACHINE SHOP, FIRST FLOOR, DETAIL OF WOOD COLUMN AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    CAR MACHINE SHOP, FIRST FLOOR, DETAIL OF WOOD COLUMN AND INVERTED KING-POST TRUSS TO PROVIDE INCREASED SPAN BETWEEN COLUMNS, LOOKING SOUTH. - Southern Pacific, Sacramento Shops, Car Machine Shop, 111 I Street, Sacramento, Sacramento County, CA

  13. Rapid determination of oxidized methionine residues in recombinant human basic fibroblast growth factor by ultra-performance liquid chromatography and electrospray ionization quadrupole time-of-flight mass spectrometry with in-source collision-induced dissociation.

    PubMed

    Ohkubo, Tsutomu; Inagaki, Shinsuke; Min, Jun Zhe; Kamiya, Daiki; Toyo'oka, Toshimasa

    2009-07-01

    The primary structure of the deteriorated recombinant human basic fibroblast growth factor (rhbFGF) was determined by ultra-performance liquid chromatography and electrospray ionization quadrupole time-of-flight mass spectrometry (UPLC/ESI-QTOF-MS) with in-source collision-induced dissociation (CID). The rhbFGFs before and after treatment with hydrogen peroxide (H(2)O(2)) were separated using an ACQUITY UPLC BEH300 C18 column (1.7 microm, 150 mm x 2.1 mm i.d.) with a gradient elution of a mixture of water/acetonitrile containing 0.1% formic acid. The separated proteins were then detected by a SYNAPT High Definition Mass Spectrometry system (SYNAPT-MS). Two methionine (Met) residues in the rhbFGF structure were oxidized to Met-sulfoxide (Met-O) in 0.03% H(2)O(2) at pH 2.0. As the result, three peaks, except for the peak of rhbFGF, appeared on the chromatogram. The three proteins corresponding to each peak were estimated as the denatured rhbFGFs including the Met-O residue(s) with TOF-MS. Furthermore, the position of the Met-O residue(s) was efficiently identified by UPLC/ESI-QTOF-MS using the in-source CID technique. The proposed method seems to be very useful for the structural elucidation of proteins, because the oxidized Met residues in rhbFGF were easily and rapidly identified.

  14. Simultaneous determination of 21 preservatives in cosmetics by ultra performance liquid chromatography.

    PubMed

    Wu, T; Wang, C; Wang, X; Ma, Q

    2008-10-01

    An ultra performance liquid chromatography (UPLC) method has been developed for the simultaneous determination of 21 preservatives: 2-methyl-4-isothiazoline-3-ketone, bronopol, 5-chloro-2-methyl-4-isothiazoline-3-ketone, benzyl alcohol, 2-phenoxyethanol, methyl-p-hydroxy benzoate, ethyl-p-hydroxy benzoate, methyl benzoate, 4-hydroxybenzoic acid iso-propyl ester, propyl-p-hydroxy benzoate, 4-chloro-3-methylphenol, ethyl benzoate, 2-phenylphenol, 4-hydroxybenzoic acid iso-butyl ester, butyl-p-hydroxy benzoate, 4-chloro-3,5-dimethylphenol, phenyl benzoate, 2,4-dichloro-3,5-dimethylphenol, 2-benzyl-4-chlorophenol, triclocarban and triclosan in cosmetics. A Waters ACQUITY UPLC BEH C(18) column was used with 0.1% formic acid solution as the mobile phase under the condition of gradient elution. Preservatives were extracted with methanol by ultrasonicator, and then they were analysed by UPLC-PDA detector. All these preservatives were baseline separated in 8.5 min. The pre-treatment method of samples and the chromatographic condition of analysis were critically examined in this study. The recoveries ranged from 90.5 to 97.8%, with RSD values below 3.2%, and all correlation coefficients (r) were no less than 0.9997. Thus, this method could be used for analysing the preservatives in cosmetic products.

  15. Validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of flecainide in human plasma and its clinical application.

    PubMed

    Mano, Yuji; Asakawa, Yoshiki; Kita, Kenji; Ishii, Takuho; Hotta, Koichiro; Kusano, Kazutomi

    2015-09-01

    A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope-labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 µm) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra- and inter-batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC-MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method.

  16. [Analysis of seven compounds in mainstream cigarette smoke by ultra performance liquid chromatography using a beta-cyclodextrin mobile phase additive].

    PubMed

    Li, Zhonghao; Tang, Gangling; Pang, Yongqiang; Jiang, Xingyi; Chen, Zaigen; Hu, Qingyuan

    2010-08-01

    A rapid method for the analysis of hydroquinone, resorcinol, catechol, phenol, p-cresol, m-cresol, and o-cresol in mainstream cigarette smoke by ultra performance liquid chromatography (UPLC) using a beta-cyclodextrin (beta-CD) mobile phase additive was developed. The seven major phenolic compounds in mainstream smoke were collected with YC/T 255-2008 standard method. The extract was filtrated with 0.22 microm filtration film and then subjected to UPLC analysis. The separation was performed on an ACQUITY UPLC BEH Shield RP18 column, and the mobile phase with 4 g/L beta-CD additive was used. The fluorescence detection condition was optimized. The analysis time was 10 mm for one sample. Comparing with the high performance liquid chromatography (HPLC) methods published, the p-cresol and m-cresol were completely separated. In addition, the effect of beta-CD on fluorescence enhancement for seven major phenolic compounds was significant. The linearity were good between the peak area and the concentration in the linear ranges of seven phenolic compounds, and the correlation coefficients were greater than 0.999 9. The limits of detection of the method were 4 - 14 ng/cig, and the recoveries were 95.5% - 103.5% with relative standard deviations (RSDs) less than 4%.

  17. [Determination of pesticide residues from seed coating reagent in agricultural products using ultra performance liquid chromatography-tandem mass spectrometry].

    PubMed

    Chen, Yue; Wang, Jinhua; Lu, Xiaoyu; Wang, Wanchun; Huang, Mei; Xu, Chaoyi

    2008-11-01

    An ultra performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) has been developed for the simultaneous determination of eight pesticide residues from seed coating in fruits, vegetable and grain. The sample was extracted by methanol-water (1:1, v/v) and determined by ultra performance liquid chromatography-electrospray ionization tandem mass spectrometry in positive mode (ESI+) and multiple reaction monitoring (MRM) mode. The UPLC analyses were performed on an Acquity UPLC C18 column with gradient eluation. The utility of the method was demonstrated by the analysis of crude extracts, with no sample clean up, from soybean. The linear range was 1 - 200 microg/L. The correlation coefficients (r) were under 0.997. The average recoveries of eight pesticides in samples (from 0.006 to 1.2 mg/kg) ranged from 60% to 110%, and the relative standard deviations (RSDs) were less than 10%. The results indicate that the method is easier, faster, more sensitive, and suitable for the qualitative and quantitative confirmation of pesticide residues from seed coating reagent in fruit, vegetable and grain samples.

  18. Cross flow cyclonic flotation column for coal and minerals beneficiation

    SciTech Connect

    Lai, R.W.; Patton, R.A.

    2000-05-02

    An apparatus and process are disclosed for the separation of coal from pyritic impurities using a modified froth flotation system. The froth flotation column incorporates a helical track about the inner wall of the column in a region intermediate between the top and base of the column. A standard impeller located about the central axis of the column is used to generate a centrifugal force thereby increasing the separation efficiency of coal from the pyritic particles and hydrophilic tailings.

  19. Cross flow flotation column for coal and minerals beneficiation

    SciTech Connect

    Lai, Ralph W.; Patton, Robert A.

    1997-12-01

    An apparatus and process are disclosed for the separation of coal from pyritic impurities using a modified froth flotation system. The froth flotation column incorporates a helical track about the inner wall of the column in a region intermediate between the top and base of the column. A standard impeller located about the central axis of the column is used to generate a centrifugal force thereby increasing the separation efficiency of coal from the pyritic particles and hydrophilic tailings.

  20. Cross flow cyclonic flotation column for coal and minerals beneficiation

    DOEpatents

    Lai, Ralph W.; Patton, Robert A.

    2000-01-01

    An apparatus and process for the separation of coal from pyritic impurities using a modified froth flotation system. The froth flotation column incorporates a helical track about the inner wall of the column in a region intermediate between the top and base of the column. A standard impeller located about the central axis of the column is used to generate a centrifugal force thereby increasing the separation efficiency of coal from the pyritic particles and hydrophillic tailings.

  1. 24. DETAIL VIEW OF COLUMN #072 DEVIATING FROM VERTICAL IN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. DETAIL VIEW OF COLUMN #072 DEVIATING FROM VERTICAL IN ROW OF INTACT COLUMNS, LOOKING NORTHEAST TO SOUTHWEST. (NOTE BOLTED BLOCK SCABBED TO COLUMN AS JOIST/TRUSS SUPPORT) - Oakland Army Base, Transit Shed, East of Dunkirk Street & South of Burma Road, Oakland, Alameda County, CA

  2. UPLC-MS-ELSD-PDA as a powerful dereplication tool to facilitate compound identification from small molecule natural product libraries

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Generation of natural product libraries containing column fractions, each with only a few small molecules, by a high throughput, automated fractionation system has made it possible to implement an improved dereplication strategy for selection and prioritization of hits in a natural product discovery...

  3. UFLC-MS/MS determination and pharmacokinetic studies of six Saikosaponins in rat plasma after oral administration of Bupleurum Dropping Pills.

    PubMed

    Guan, Xiufeng; Wang, Xiangyang; Yan, Kaijing; Chu, Yang; Li, Shuming; Li, Wei; Yan, Xueying; Ma, Xiaohui; Zhou, Shuiping; Sun, He; Liu, Changxiao

    2016-05-30

    A rapid and sensitive ultra fast liquid chromatography tandem mass spectrometry method (UFLC-MS/MS) was developed and validated for the simultaneous determination of six Saikosaponins (SSs) (SSa, SSb1, SSb2, SSd, SSc, SSf) of Bupleurum Dropping Pills (BDP) in rat plasma using chloramphenicol as the internal standard (IS). The SSs were separated using an ACQUITY UPLC(®) BEH C18 column (50 mm × 2.1mm, 1.7 μm) and detection of these compounds were done by using a Qtrap 5500 mass spectrometer coupled with negative electrospray ionization (ESI) source under the multiple reaction monitoring (MRM) mode. According to regulatory guidelines, the established method was fully validated and results were showed within acceptable limits. The lower limit of quantifications (LLOQs) of all analytes were 0.2 ng/mL. The validated method was successfully applied into a pharmacokinetic study of orally administered BDP in rats.

  4. Growing Cobalt Silicide Columns In Silicon

    NASA Technical Reports Server (NTRS)

    Fathauer, Obert W.

    1991-01-01

    Codeposition by molecular-beam epitaxy yields variety of structures. Proposed fabrication process produces three-dimensional nanometer-sized structures on silicon wafers. Enables control of dimensions of metal and semiconductor epitaxial layers in three dimensions instead of usual single dimension (perpendicular to the plane of the substrate). Process used to make arrays of highly efficient infrared sensors, high-speed transistors, and quantum wires. For fabrication of electronic devices, both shapes and locations of columns controlled. One possible technique for doing this electron-beam lithography, see "Making Submicron CoSi2 Structures on Silicon Substrates" (NPO-17736).

  5. OH vertical column abundance - Tropical measurements

    NASA Astrophysics Data System (ADS)

    Burnett, Clyde R.; Minschwaner, Kenneth R.; Burnett, Elizabeth B.

    1990-09-01

    Measurements of the vertical column abundance of atmospheric hydroxyl (OH) have been made during the period 1987-1989 at the National Weather Service (NWS) station at Moen, Truk, Federated States of Micronesia (7 deg N, 152 deg E). A total of 384 independent data sets was obtained. Tropical OH abundance levels average about 22 percent above corresponding mid-latitude values, with OH levels during late winter and early spring up to 50 percent above those observed at 40 deg N. Stratospheric wind and temperature data obtained from the daily NWS radiosonde data are examined for correlations with the OH results.

  6. OH vertical column abundance - Tropical measurements

    NASA Technical Reports Server (NTRS)

    Burnett, Clyde R.; Minschwaner, Kenneth R.; Burnett, Elizabeth B.

    1990-01-01

    Measurements of the vertical column abundance of atmospheric hydroxyl (OH) have been made during the period 1987-1989 at the National Weather Service (NWS) station at Moen, Truk, Federated States of Micronesia (7 deg N, 152 deg E). A total of 384 independent data sets was obtained. Tropical OH abundance levels average about 22 percent above corresponding mid-latitude values, with OH levels during late winter and early spring up to 50 percent above those observed at 40 deg N. Stratospheric wind and temperature data obtained from the daily NWS radiosonde data are examined for correlations with the OH results.

  7. A review of oscillating water columns.

    PubMed

    Heath, T V

    2012-01-28

    This paper considers the history of oscillating water column (OWC) systems from whistling buoys to grid-connected power generation systems. The power conversion from the wave resource through to electricity via pneumatic and shaft power is discussed in general terms and with specific reference to Voith Hydro Wavegen's land installed marine energy transformer (LIMPET) plant on the Scottish island of Islay and OWC breakwater systems. A report on the progress of other OWC systems and power take-off units under commercial development is given, and the particular challenges faced by OWC developers reviewed.

  8. 9. Detail view of columns on first floor. This row ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Detail view of columns on first floor. This row of columns indicates the former location of the exterior mill wall before World War II era expansion. The unusual column and beam connection was a key part of the mill structural system patented by Providence, Rhode Island engineers Charles Praray and Charles Makepeace in 1894. Each column was originally located in the apex of triangular window bay, but not connected to the exterior wall. Modifications on the right side of each column support the beams of the addition. - Dixie Cotton Mill, 710 Greenville Street, La Grange, Troup County, GA

  9. Enhanced column flotation of fine and ultrafine coal

    SciTech Connect

    Slomka, B.J.; Buttermore, W.H.; Birlingmair, D.H.; Dawson, M.R.; Pollard, J.L.; Enustun, B.V.

    1992-12-01

    A 2-inch diameter, twenty-foot tall, glass laboratory flotation column was modified to incorporate digital control of critical operating parameters. Different column control strategies were explored including location of the froth interface, and manipulation of volumetric flow ratios. Column flotation tests were performed with both fine (-250{mu}m) and ultrafine (-5{mu}m) Pittsburgh seam coal. Both moisture- and ash-free (MAF) recovery, and ash rejection were improved when the partition of the column`s liquid content into froth and tailings was directly controlled. MAF recovery and ash rejection were also enhanced by brief exposure of the coarser feed to pulsed sonic energy.

  10. UPLC-PDA-QTOFMS-guided isolation of prenylated xanthones and benzoylphloroglucinols from the leaves of Garcinia oblongifolia and their migration-inhibitory activity

    PubMed Central

    Zhang, Hong; Dan, Zheng; Ding, Zhi-Jie; Lao, Yuan-Zhi; Tan, Hong-Sheng; Xu, Hong-Xi

    2016-01-01

    A UPLC-PDA-QTOFMS-guided isolation strategy was employed to screen and track potentially new compounds from Garcinia oblongifolia. As a result, two new prenylated xanthones, oblongixanthones D and E (1–2), six new prenylated benzoylphloroglucinol derivatives, oblongifolins V–Z (3–7) and oblongifolin AA (8), as well as a known compound oblongifolin L (9), were isolated from the EtOAc-soluble fraction of an acetone extract of the leaves of Garcinia oblongifolia guided by UPLC-PDA-QTOFMS analysis. The structures of the new compounds were elucidated by 1D- and 2D-NMR spectroscopic analysis and mass spectrometry. Experimental and calculated ECD spectra were used to determine the absolute configurations. The results of wound healing and transwell migration assay showed that oblongixanthones D (1), E (2), and oblongifolin L (9) have the ability to inhibit cancer cell migration in lower cytotoxic concentrations. Western blotting results showed that these compounds exhibited an anti-metastasis effect mainly through downregulating RAF protein levels. In addition, 2 and 9 could inhibit phospho-MEK and phospho-ERK at downstream. Moreover, 1, 2, and 9 could inhibit snail protein level, suggesting that they could regulate the EMT pathway. PMID:27767059

  11. Screening of lignan patterns in Schisandra species using ultrasonic assisted temperature switch ionic liquid microextraction followed by UPLC-MS/MS analysis.

    PubMed

    Dong, Wei; Yu, Shuijing; Deng, Yangwu; Pan, Tao

    2016-01-01

    The ultrasonic assisted temperature-switch ionic liquid microextraction (UATS-ILME) has been successfully applied in extracting of seven lignans from Schisandra. 1-Butyl-3-methylimidazolium tetrafluoroborate ([C4MIM][BF4]) aqueous solution was selected for extracting the target analytes in raw material at 80°C. The lignans were deposited into a single drop by in situ forming 1-butyl-3-methylimidazolium hexafluorophosphate ([C4MIM][PF6]) by cooling down to 0°C and centrifuging for 10min. The extracts were analyzed by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in a robust multiple-reaction monitoring (MRM) mode in five minutes. Meanwhile, the proposed method was validated and successfully applied to the determination of seven lignans in twelve Schisandra species. The results indicated that UATS-ILME combined with UPLC-MS/MS is a powerful and practical tool, which has great potential for comprehensive quality control of herbal medicines.

  12. New UPLC coupled to mass spectrometry approaches for screening of non-volatile compounds as potential migrants from adhesives used in food packaging materials.

    PubMed

    Canellas, E; Nerín, C; Moore, R; Silcock, P

    2010-05-07

    The objective of this study was to identify the non-volatile compounds as potential migrants from adhesives used in food packaging. A number of the current acrylic adhesive formulations were extracted and prepared for analysis. The extracts were screened using ultra-performance liquid chromatography coupled to a time-of-flight mass spectrometer detector (UPLC-TOF-MS). This approach allowed the identification of several components by a combination of exact mass and in-source collision induced dissociation (CID). Due to the lack of freely available information on adhesive formulations further analyses were undertaken using ultra-performance liquid chromatography coupled to high definition mass spectrometry (UPLC-HDMS). Using the Mass Fragment tool to interrogate fragmentation data, a wide series of compounds were identified, demonstrating the usefulness and importance of these tools for difficult problems. Moreover, using several packaging materials containing adhesives, qualitative migration tests were performed with Tenax as a food simulant. Several non-volatile compounds were identified as well in the Tenax which emphasizes the importance of this work and demonstrates that even the non-volatile compounds have the potential to migrate into food which is in contact with packaging materials. The main characteristics of the screening study and the results obtained are shown and discussed.

  13. Rapid and selective quantification of L-theanine in ready-to-drink teas from Chinese market using SPE and UPLC-UV.

    PubMed

    Chen, Guoqiang; Wang, Yun; Song, Weiqi; Zhao, Bo; Dou, Yuling

    2012-11-15

    An ultra performance liquid chromatography (UPLC) method combined with solid phase extraction (SPE) sample pre-treatment was developed and validated for the rapid quantification of L-theanine in ready-to-drink (RTD) teas. UPLC analysis of twenty-seven RTD teas from the Chinese market revealed that the L-theanine levels in various types of RTD teas were significantly different. RTD green teas were found to contain highest mean L-theanine level (37.85±20.54 mg/L), followed by jasmine teas (36.60±12.08 mg/L), Tieguanying teas (18.54±3.46 mg/L) black teas (16.89±6.56), Pu-erh teas (11.31±0.90 mg/L) and oolong teas (3.85±2.27 mg/L). The ratio of total polyphenols content to L-theanine content could be used as a featured parameter for differentiating RTD teas. L-theanine in RTD teas could be a reliable quality parameter that is complementary to total polyphenols.

  14. Association between Oxidative DNA Damage and Risk of Colorectal Cancer: Sensitive Determination of Urinary 8-Hydroxy-2‧-deoxyguanosine by UPLC-MS/MS Analysis

    NASA Astrophysics Data System (ADS)

    Guo, Cheng; Li, Xiaofen; Wang, Rong; Yu, Jiekai; Ye, Minfeng; Mao, Lingna; Zhang, Suzhan; Zheng, Shu

    2016-09-01

    Oxidative DNA damage plays crucial roles in the pathogenesis of numerous diseases including cancer. 8-hydroxy-2‧-deoxyguanosine (8-OHdG) is the most representative product of oxidative modifications of DNA, and urinary 8-OHdG is potentially the best non-invasive biomarker of oxidative damage to DNA. Herein, we developed a sensitive, specific and accurate method for quantification of 8-OHdG in human urine. The urine samples were pretreated using off-line solid-phase extraction (SPE), followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis. By the use of acetic acid as an additive to the mobile phase, we improved the UPLC-MS/MS detection of 8-OHdG by 2.7‑5.3 times. Using the developed strategy, we measured the contents of 8-OHdG in urine samples from 142 healthy volunteers and 84 patients with colorectal cancer (CRC). We observed increased levels of urinary 8-OHdG in patients with CRC and patients with tumor metastasis, compared to healthy controls and patients without tumor metastasis, respectively. Additionally, logistic regression analysis and receiver operator characteristic (ROC) curve analysis were performed. Our findings implicate that oxidative stress plays important roles in the development of CRC and the marked increase of urinary 8-OHdG may serve as a potential liquid biomarker for the risk estimation, early warning and detection of CRC.

  15. UPLC-PDA-QTOFMS-guided isolation of prenylated xanthones and benzoylphloroglucinols from the leaves of Garcinia oblongifolia and their migration-inhibitory activity

    NASA Astrophysics Data System (ADS)

    Zhang, Hong; Dan, Zheng; Ding, Zhi-Jie; Lao, Yuan-Zhi; Tan, Hong-Sheng; Xu, Hong-Xi

    2016-10-01

    A UPLC-PDA-QTOFMS-guided isolation strategy was employed to screen and track potentially new compounds from Garcinia oblongifolia. As a result, two new prenylated xanthones, oblongixanthones D and E (1–2), six new prenylated benzoylphloroglucinol derivatives, oblongifolins V–Z (3–7) and oblongifolin AA (8), as well as a known compound oblongifolin L (9), were isolated from the EtOAc-soluble fraction of an acetone extract of the leaves of Garcinia oblongifolia guided by UPLC-PDA-QTOFMS analysis. The structures of the new compounds were elucidated by 1D- and 2D-NMR spectroscopic analysis and mass spectrometry. Experimental and calculated ECD spectra were used to determine the absolute configurations. The results of wound healing and transwell migration assay showed that oblongixanthones D (1), E (2), and oblongifolin L (9) have the ability to inhibit cancer cell migration in lower cytotoxic concentrations. Western blotting results showed that these compounds exhibited an anti-metastasis effect mainly through downregulating RAF protein levels. In addition, 2 and 9 could inhibit phospho-MEK and phospho-ERK at downstream. Moreover, 1, 2, and 9 could inhibit snail protein level, suggesting that they could regulate the EMT pathway.

  16. Analysis of 2-(2-Phenylethyl)chromones by UPLC-ESI-QTOF-MS and Multivariate Statistical Methods in Wild and Cultivated Agarwood.

    PubMed

    Li, Yuanbin; Sheng, Nan; Wang, Lingli; Li, Shijie; Chen, Jiannan; Lai, Xiaoping

    2016-05-23

    Agarwood is the fragrant resinous material mainly formed from species of Aquilaria. 2-(2-phenylethyl)chromones, especially the highly oxidized 5,6,7,8-tetrahydro-2-(2-phenylethyl)chromones, are the main representative compounds from agarwood. It is important to determine whether agarwood in trade is from cultivated trees or natural trees in the Convention on the International Trade in Endangered Species (CITES). We characterized the 2-(2-phenylethyl)chromones in agarwood by ultra-performance liquid chromatography coupled with electrospray ionization mass spectrometry (UPLC-ESI-QTOF-MS) and differentiated wild from cultivated agarwood by metabolomic analysis. A total of 141 chromones including 50 potentially new compounds were evaluated as belonging to four structural classes (unoxidized 2-(2-phenylethyl)chromones, 5,6,7,8-tetrahydro-2-(2-phenylethyl)-chromones, bi-2-(2-phenylethyl)chromones, and tri-2-(2-phenylethyl)chromones). The metabolic difference between wild and cultivated agarwood was analyzed by component analysis (PCA) and orthogonal partial least squares discriminant analysis (OPLS-DA). Fourteen markers of metabolisms in wild and cultivated agarwood were constructed (e.g., 6,7-dimethoxy-2-(2-phenylethyl)chromone, 6,8-dihydroxy-2-(2-phenylethyl)chromone, 6-methoxy-2-(2-phenylethyl)chromone, etc.). These results indicated that UPLC-ESI-QTOF-MS-based metabonomics analysis in agarwood may be useful for distinguishing wild agarwood from cultivated agarwood.

  17. Characterization of the Principal Constituents of Danning Tablets, a Chinese Formula Consisting of Seven Herbs, by an UPLC-DAD-MS/MS Approach.

    PubMed

    Zhan, Changsen; Xiong, Aizhen; Shen, Danping; Yang, Li; Wang, Zhengtao

    2016-05-14

    Danning Tablets are a traditional Chinese formula showing broad clinical applications in hepatobiliary diseases and containing a diversity of bioactive chemicals. However, the chemical profiling of the formula, which serves as the material foundation of its efficacy, is really a big challenge as Danning Tablets consist of seven herbs from different origins. An ultra-performance liquid chromatography coupled to diode array detection and electrospray ionization mass spectrometry (UPLC-DAD-ESI-MS/MS) approach was developed to characterize the principal polyphenol constituents in the formula. As a result, a total of 32 constituents, including 14 anthraquinones and their glucosides, four anthrones, two naphthalene glycosides, two stilbenes and 10 flavonoids were identified based on their retention time, UV absorption and MS/MS fragmentation patterns. The sources of these compounds were also illustrated. Most of the bioactive anthraquinone derivatives were found in Rhei Radix et Rhizoma or Polygoni Cuspidati Rhizoma et Radix, which are the Emperor drugs in the formula for its clinic usage. These findings indicate the merit of using this integrated UPLC-DAD-ESI-MS/MS approach to rapidly illustrate the chemical foundation of complex formulas. The present study will facilitate the quality control of Danning Tablet formulas as well as the individual herbs.

  18. Chemical differentiation of Da-Cheng-Qi-Tang, a Chinese medicine formula, prepared by traditional and modern decoction methods using UPLC/Q-TOFMS-based metabolomics approach.

    PubMed

    Wan, Jian-Bo; Bai, Xu; Cai, Xiu-Jiang; Rao, Yi; Wang, Yue-Sheng; Wang, Yi-Tao

    2013-09-01

    In order to evaluate chemical consistency between traditional and modern decoctions of Da-Cheng-Qi-Tang (DCQT), a classical Chinese medicine formula commonly used in the treatment of digestive diseases, an ultra performance liquid chromatography-electrospray ionization-quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q-TOFMS) combined with multivariate statistical analysis was established to globally characterize the chemical profile and discover differentiating chemical markers. Two kinds of decoctions, namely traditional decoction (multi-step decoction of constituent herbs), and modern decoction (one-step decoction of all herbs), were prepared and subjected to UPLC-MS analysis, the datasets of tR-m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis (OPLS-DA) to comprehensively compare the chemical difference between these two kinds of decoction samples. The global chemical difference was found between traditional and modern decoctions, and rhein, sennoside A/B, diosmetin, magnoloside B and naringin were the components contributing most to these differences. Based on the fact that traditional decoction of DCQT presents the higher concentration of rhein and sennoside A/B, mainly contributed to laxative activity of DCQT, the purgative effect of traditional decoction might be more potent, compared with modern decoction. However, the comparative study on purgative effect of traditional and modern DCQT remains to be further investigated using pharmacological approaches. Our findings also provide the early scientific evidence of traditional decoction method of DCQT.

  19. Metabolomic Approach for Discrimination of Four- and Six-Year-Old Red Ginseng (Panax ginseng) Using UPLC-QToF-MS.

    PubMed

    Shin, Jung-Sub; Park, Hee-Won; In, Gyo; Seo, Hyun Kyu; Won, Tae Hyung; Jang, Kyoung Hwa; Cho, Byung-Goo; Han, Chang Kyun; Shin, Jongheon

    2016-09-01

    Panax ginseng C.A. MEYER is one of the most popular medicinal herbs in Asia and the chemical constituents are changed by processing methods such as steaming or sun drying. Metabolomic analysis was performed to distinguish age discrimination of four- and six-year-old red ginseng using ultra-performance liquid chromatography quadruple time of flight mass spectrometry (UPLC-QToF-MS) with multivariate statistical analysis. Principal component analysis (PCA) showed clear discrimination between extracts of red ginseng of different ages and suggest totally six discrimination markers (two for four-year-old and four for six-year-old red ginseng). Among these, one marker was isolated and the structure determined by NMR spectroscopic analysis was 13-cis-docosenamide (marker 6-1) from six-year-old red ginseng. This is the first report of a metabolomic study regarding the age differentiation of red ginseng using UPLC-QToF-MS and determination of the structure of the marker. These results will contribute to the quality control and standardization as well as provide a scientific basis for pharmacological research on red ginseng.

  20. Fast UPLC/PDA determination of squalene in Sicilian P.D.O. pistachio from Bronte: Optimization of oil extraction method and analytical characterization.

    PubMed

    Salvo, Andrea; La Torre, Giovanna Loredana; Di Stefano, Vita; Capocchiano, Valentina; Mangano, Valentina; Saija, Emanuele; Pellizzeri, Vito; Casale, Katia Erminia; Dugo, Giacomo

    2017-04-15

    A fast reversed-phase UPLC method was developed for squalene determination in Sicilian pistachio samples that entry in the European register of the products with P.D.O. In the present study the SPE procedure was optimized for the squalene extraction prior to the UPLC/PDA analysis. The precision of the full analytical procedure was satisfactory and the mean recoveries were 92.8±0.3% and 96.6±0.1% for 25 and 50mgL(-1) level of addition, respectively. Selected chromatographic conditions allowed a very fast squalene determination; in fact it was well separated in ∼0.54min with good resolution. Squalene was detected in all the pistachio samples analyzed and the levels ranged from 55.45-226.34mgkg(-1). Comparing our results with those of other studies it emerges that squalene contents in P.D.O. Sicilian pistachio samples, generally, were higher than those measured for other samples of different geographic origins.

  1. Identification of NF-κB inhibitors in Qishenyiqi dropping pills for myocardial infarction treatment based on bioactivity-integrated UPLC-Q/TOF MS.

    PubMed

    Han, Yanqi; Zhou, Mengge; Xing, Lu; Jiang, Min; Bai, Gang; Luo, Guoan

    2015-10-01

    Qishenyiqi dropping pills (QSYQ) are a type of standardized cardiovascular multiherb medicine for the treatment of myocardial infarction (MI). Knowledge concerning the systemic identification of nuclear factor-kappa B (NF-κB) inhibitors of QSYQ is generally lacking. Therefore, it is necessary to establish an effective method to screen the bioactive components of NF-κB inhibition. In the present study, a rat model of coronary artery ligation was used to assess the cardioprotective effects of QSYQ. The electrocardiograms, histopathology of heart tissues and serum biochemical indicators, such as brain natriuretic peptide, cardiac troponin I and inflammatory cytokines, were measured. Subsequently, ultra-performance liquid chromatography quadrupole/time-of-flight mass spectrometry (UPLC-Q/TOF MS) combined with the NF-κB luciferase reporter assay system was applied to screen the potential anti-inflammatory compounds in QSYQ. The results revealed that the administration of QSYQ could improve heart function, ameliorate neutrophil infiltration and diminish the levels of inflammatory cytokines in MI rats. Furthermore, 22 compounds were determined to be potential NF-κB inhibitors. In conclusion, NF-κB inactivation and cytokine suppression might be the main mechanisms of QSYQ for MI treatment. The method of UPLC-Q/TOF MS combined with a bioactive human cell functional evaluation system was proved to be a simple and effective strategy for screening bioactive compounds in traditional Chinese medicine prescriptions.

  2. Association between Oxidative DNA Damage and Risk of Colorectal Cancer: Sensitive Determination of Urinary 8-Hydroxy-2′-deoxyguanosine by UPLC-MS/MS Analysis

    PubMed Central

    Guo, Cheng; Li, Xiaofen; Wang, Rong; Yu, Jiekai; Ye, Minfeng; Mao, Lingna; Zhang, Suzhan; Zheng, Shu

    2016-01-01

    Oxidative DNA damage plays crucial roles in the pathogenesis of numerous diseases including cancer. 8-hydroxy-2′-deoxyguanosine (8-OHdG) is the most representative product of oxidative modifications of DNA, and urinary 8-OHdG is potentially the best non-invasive biomarker of oxidative damage to DNA. Herein, we developed a sensitive, specific and accurate method for quantification of 8-OHdG in human urine. The urine samples were pretreated using off-line solid-phase extraction (SPE), followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) analysis. By the use of acetic acid as an additive to the mobile phase, we improved the UPLC-MS/MS detection of 8-OHdG by 2.7−5.3 times. Using the developed strategy, we measured the contents of 8-OHdG in urine samples from 142 healthy volunteers and 84 patients with colorectal cancer (CRC). We observed increased levels of urinary 8-OHdG in patients with CRC and patients with tumor metastasis, compared to healthy controls and patients without tumor metastasis, respectively. Additionally, logistic regression analysis and receiver operator characteristic (ROC) curve analysis were performed. Our findings implicate that oxidative stress plays important roles in the development of CRC and the marked increase of urinary 8-OHdG may serve as a potential liquid biomarker for the risk estimation, early warning and detection of CRC. PMID:27585556

  3. Rapid determination of alkaloids in Macleaya cordata using ionic liquid extraction followed by multiple reaction monitoring UPLC-MS/MS analysis.

    PubMed

    Li, Linqiu; Huang, Mingyuan; Shao, Junli; Lin, Bokun; Shen, Qing

    2017-02-20

    The ultrasonic-assisted extraction (UAE) and ionic liquid based dispersive liquid-liquid microextraction (IL-DLLME) have been successfully applied in extracting of six alkaloids from M. cordata. 1-hexyl-3-methylimidazolium tetrafluoroborate ([C6MIM][BF4]) aqueous solution was used as extraction solvent. The target analytes in raw material were deposited into a single drop of 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]), which was in situ formed by mixing [C6MIM][BF4] and potassium hexafluorophosphate ([K][PF6]. Afterwards, the extract was analyzed by ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) in multiple-reaction monitoring (MRM) mode. The proposed method was fully validated in terms of linearity (0.9983-0.9992), LOD (0.080ngmL(-1)), LOQ (0.25ngmL(-1)), intra-day precision (<5.46%), inter-day precision (<6.36%), and recovery (86.42-112.48%). The results indicate that the approach of combining IL-DLLME with UPLC-MS/MS is powerful and practical for analyzing alkaloids in M. cordata., and it also has great potential for comprehensive quality control of other herbal medicines.

  4. Ionic liquids monolithic columns for protein separation in capillary electrochromatography.

    PubMed

    Liu, Cui-Cui; Deng, Qi-Liang; Fang, Guo-Zhen; Liu, Hui-Lin; Wu, Jian-Hua; Pan, Ming-Fei; Wang, Shuo

    2013-12-04

    A series of ionic liquids (ILs) monolithic capillary columns based on 1-vinyl-3-octylimidazolium (ViOcIm(+)) were prepared by two approaches ("one-pot" approach and "anion-exchange" approach). The effects of different anions (bromide, Br(-); tetrafluoroborate, BF4(-); hexafluorophosphate, PF6(-); and bis-trifluoromethanesulfonylimide, NTf2(-)) on chromatography performance of all the resulting columns were investigated systematically under capillary electrochromatography (CEC) mode. The results indicated that all these columns could generate a stable reversed electroosmotic flow (EOF) over a wide pH range from 2.0 to 12.0. For the columns prepared by "one-pot" approach, the EOF decreased in the order of ViOcIm(+)Br(-)>ViOcIm(+)BF4(-)>ViOcIm(+)PF6(-)>ViOcIm(+)NTf2(-) under the same CEC conditions; the ViOcIm(+)Br(-) based column exhibited highest column efficiencies for the test small molecules; the ViOcIm(+)NTf2(-) based column possessed the strongest retention for aromatic hydrocarbons; and baseline separation of four standard proteins was achieved on ViOcIm(+)NTf2(-) based column corresponding to the highest column efficiency of 479,000 N m(-1) for cytochrome c (Cyt c). These results indicated that the property of ILs based columns could be tuned successfully by changing anions, which gave these columns potential to separate both small molecules and macro biomolecules.

  5. Curvature ductility of reinforced and prestressed concrete columns

    SciTech Connect

    Suprenant, B.A.

    1984-01-01

    Engineers are concerned with the survival of reinforced and prestressed concrete columns during earthquakes. The prediction of column survival can be deduced from moment-curvature curves of the column section. An analytical approach is incorporated into a computer model. The computer program is based on assumed stress-strain relations for confined and unconfined concrete, nonprestressed and prestressing steel. The results of studies on reinforced and prestressed concrete columns indicate that reinforced concrete columns may be designed to resist earthquakes, while prestressed concrete columns may not. The initial reduction in moment capacity, after concrete cover spalling, of a prestressed concrete column could be as much as 50%. Analyses indicate that the bond between concrete and prestressing strand after concrete cover spalling is not critical.

  6. Interactions of evaportranspiration between two parallel columns

    NASA Astrophysics Data System (ADS)

    Sun, D.; Zhu, J.

    2010-12-01

    Moisture flux across the land-atmosphere boundary (through soil evaporation and plant transpiration) is an important component of many large-scale hydrological processes, which were often quantified through simulation of multiple realizations (stream tubes) of independent one-dimensional local scale flow. A major problem of this approach is that it ignores the interactions among different stream tubes. Lateral flows might be prominent for long and narrow tubes and heterogeneous hydraulic properties and plant covers. This study is to investigate whether using this stream tube modeling will produce unacceptable errors for large scale evapotranspiration simulations. Instead of using convenient parallel column models of independent hydrologic processes, this study simulates two-dimensional transpiration and evaporation in two parallel columns which allow lateral interactions. The impact of both plant characteristics and soil hydraulic properties on evapotranspitration is addressed and discussed in comparison to those of independent stream tube models. The results provide applicable guidance for applications of stream tube models to simulate large scale evapotranspiration in a heterogeneous landscape.

  7. Microparticle column geometry in acoustic stationary fields.

    PubMed

    Hancock, Andrew; Insana, Michael F; Allen, John S

    2003-01-01

    Particles suspended in a fluid will experience forces from stationary acoustic fields. The magnitude of the force depends on the time-averaged energy density of the field and the material properties of the particles and fluid. Forces acting on known particles smaller than 20 microm were studied. Within a 500 kHz acoustic beam generated by a plane-piston circular source, observations were made of the geometry of the particle column that is formed. Varying the acoustic energy altered the column width in a manner predicted by equations for the primary acoustic radiation force from scattering of particles in the long-wavelength limit. The minimum pressures required to trap gas, solid, and liquid particles in a water medium at room temperature were also estimated to within 12%. These results highlight the ability of stationary acoustic fields from a plane-piston radiator to impose nano-Newton-scale forces onto fluid particles with properties similar to biological cells, and suggest that it is possible to accurately quantify these forces.

  8. Monolithic columns in plant proteomics and metabolomics.

    PubMed

    Rigobello-Masini, Marilda; Penteado, José Carlos Pires; Masini, Jorge Cesar

    2013-03-01

    Since "omics" techniques emerged, plant studies, from biochemistry to ecology, have become more comprehensive. Plant proteomics and metabolomics enable the construction of databases that, with the help of genomics and informatics, show the data obtained as a system. Thus, all the constituents of the system can be seen with their interactions in both space and time. For instance, perturbations in a plant ecosystem as a consequence of application of herbicides or exposure to pollutants can be predicted by using information gathered from these databases. Analytical chemistry has been involved in this scientific evolution. Proteomics and metabolomics are emerging fields that require separation, identification, and quantification of proteins, peptides, and small molecules of metabolites in complex biological samples. The success of this work relies on efficient chromatographic and electrophoretic techniques, and on mass spectrometric detection. This paper reviews recent developments in the use of monolithic columns, focusing on their applications in "top-down" and "bottom-up" approaches, including their use as supports for immobilization of proteolytic enzymes and their use in two-dimensional and multidimensional chromatography. Whereas polymeric columns have been predominantly used for separation of proteins and polypeptides, silica-based monoliths have been more extensively used for separation of small molecules of metabolites. Representative applications in proteomics and in analysis of plant metabolites are given and summarized in tables.

  9. Ultrasensitive UPLC-MS/MS method for analysis of etheno-DNA adducts in human white blood cells.

    PubMed

    Li, H; Cui, S; Wang, S; Jiang, X; Zhang, S; Zhang, R; Fu, P P; Sun, X

    2015-01-01

    Etheno-DNA adducts are generated by interaction of cellular DNA with exogenous environmental carcinogens and end products of lipid peroxidation. It has been determined that 1,N(6)-etheno-2'-deoxyadenosine (εdA) and 3,N(4)-etheno-2'-deoxycytidine (εdC) adducts formed in human white blood cells can be used to serve as biomarkers of genetic damage mediated by oxidative stress. In this study, we developed an ultrasensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method used to detect and quantify εdA and dC adducts in human white blood cells. The percent recoveries of εdA and dC adducts were found to be 88.9% ± 2.8 and 95.7% ± 3.7, respectively. The detection limits were ∼ 1.45 fmol for εdA and ∼ 1.27 fmol for εdC in 20 μg of human white blood cell DNA samples, both εdA and εdC adducts could be detected using only ∼ 5 μg of DNA per sample. For validation of the method, 34 human blood cell DNA samples were assayed and the results revealed a significant difference (P < 0.01) between levels (fmol/μg DNA) of 0.82 ± 0.83 (standard deviation [SD]) (range: 0.15-3.11) for εdA, 3.28 ± 3.15 (SD) (range: 0.05-9.6) for εdC in benzene-exposed workers; and 0.04 ± 0.08 (SD) (range: 0.0-0.27) for εdA and 0.77 ± 1.02 (SD) (range: 0.10-4.11) for εdC in non-benzene-exposed workers. Our method shows a high sensitivity and specificity when applied to small amounts of human white blood cell DNA samples; background levels of εdA and εdC could be reproducibly detected. The ultrasensitive and simple detection method is thus suitable for applications in human biomonitoring and molecular epidemiology studies.

  10. Development and Validation of a UPLC-MS/MS Method to Monitor Cephapirin Excretion in Dairy Cows following Intramammary Infusion

    PubMed Central

    Ray, Partha; Knowlton, Katharine F.; Shang, Chao; Xia, Kang

    2014-01-01

    Cephapirin, a cephalosporin antibiotic, is used by the majority of dairy farms in the US. Fecal and urinary excretion of cephapirin could introduce this compound into the environment when manure is land applied as fertilizer, and may cause development of bacterial resistance to antibiotics critical for human health. The environmental loading of cephapirin by the livestock industry remains un-assessed, largely due to a lack of appropriate analytical methods. Therefore, this study aimed to develop and validate a cephapirin quantification method to capture the temporal pattern of cephapirin excretion in dairy cows following intramammary infusion. The method includes an extraction with phosphate buffer and methanol, solid-phase extraction (SPE) clean-up, and quantification using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The LOQ values of the developed method were 4.02 µg kg−1 and 0.96 µg L−1 for feces and urine, respectively. This robust method recovered >60% and >80% cephapirin from spiked blank fecal and urine samples, respectively, with acceptable intra- and inter-day variation (<10%). Using this method, we detected trace amounts (µg kg−1) of cephapirin in dairy cow feces, and cephapirin in urine was detected at very high concentrations (133 to 480 µg L−1). Cephapirin was primarily excreted via urine and its urinary excretion was influenced by day (P = 0.03). Peak excretion (2.69 mg) was on day 1 following intramammary infusion and decreased sharply thereafter (0.19, 0.19, 0.08, and 0.17 mg on day 2, 3, 4, and 5, respectively) reflecting a quadratic pattern of excretion (Quadratic: P = 0.03). The described method for quantification of cephapirin in bovine feces and urine is sensitive, accurate, and robust and allowed to monitor the pattern of cephapirin excretion in dairy cows. This data will help develop manure segregation and treatment methods to minimize the risk of antibiotic loading to the environment

  11. Reliable quantification of bisphenol A and its chlorinated derivatives in human urine using UPLC-MS/MS method.

    PubMed

    Venisse, N; Grignon, C; Brunet, B; Thévenot, S; Bacle, A; Migeot, V; Dupuis, A

    2014-07-01

    Bisphenol A (BPA), a widespread man-made chemical classified as an endocrine disruptor, is increasingly considered as a major cause of concern for human health. Chlorine present in drinking water may react with BPA to form chlorinated derivatives (ClxBPA), which have demonstrated a heightened level of estrogenic activity. If many epidemiological studies report that more than 90% of people have detectable BPA levels in their urine, then no such study has been undertaken regarding ClxBPA. The purpose of this work is to propose a highly sensitive and accurate analytical method adapted to large-scale biomonitoring studies aimed at assessing exposure to BPA and ClxBPA through the use of human urine. To achieve this, we have comprehensively validated a method using salting-out assisted liquid/liquid extraction (SALLE) coupled to UPLC-MS/MS and isotope dilution quantification, to measure unconjugated BPA and ClxBPA in human urine according to the accepted guidelines. Deutered BPA as well as deutered 2,2'-DCBPA was used as internal standards. The matrix calibration curve ranged from 0.05 to 1.60 ng mL(-1) and from 0.5 to 16.0 ng mL(-1) for ClxBPA and BPA respectively, and provided good linearity (r²>0.99). This method was precise (the intra- and inter-day coefficients of variation were <20% at three different concentrations: 0.05 ng mL(-1), 0.2 ng mL(-1), 0.8 ng mL(-1) and 0.5 ng mL(-1), 2 ng mL(-1), 8 ng mL(-1) for ClxBPA and BPA, respectively) and accurate (bias ranged from -13% to +12%). The limit of quantification, validated at 0.05 ng mL(-1) and 0.5 ng mL(-1) for ClxBPA and BPA respectively when using 300 µL of urine, was found to be suitable for the concentration existing in real samples. The matrix effect and the BPA cross-contamination were also investigated in this study. The analytical method developed in this study is in accordance with the requirements applicable to biomonitoring of BPA and ClxBPA in human urine.

  12. Comparison of automated pre-column and post-column analysis of amino acid oligomers

    NASA Technical Reports Server (NTRS)

    Chow, J.; Orenberg, J. B.; Nugent, K. D.

    1987-01-01

    It has been shown that various amino acids will polymerize under plausible prebiotic conditions on mineral surfaces, such as clays and soluble salts, to form varying amounts of oligomers (n = 2-6). The investigations of these surface reactions required a quantitative method for the separation and detection of these amino acid oligomers at the picomole level in the presence of nanomole levels of the parent amino acid. In initial high-performance liquid chromatography (HPLC) studies using a classical postcolumn o-phthalaldehyde (OPA) derivatization ion-exchange HPLC procedure with fluorescence detection, problems encountered included lengthy analysis time, inadequate separation and large relative differences in sensitivity for the separated species, expressed as a variable fluorescent yield, which contributed to poor quantitation. We have compared a simple, automated, pre-column OPA derivatization and reversed-phase HPLC method with the classical post-column OPA derivatization and ion-exchange HPLC procedure. A comparison of UV and fluorescent detection of the amino acid oligomers is also presented. The conclusion reached is that the pre-column OPA derivatization, reversed-phase HPLC and UV detection produces enhanced separation, improved sensitivity and faster analysis than post-column OPA derivatization, ion-exchange HPLC and fluorescence detection.

  13. Ultra-performance liquid chromatography tandem mass-spectrometry (uplc-ms/ms) for the rapid, simultaneous analysis of thiamin, riboflavin, flavin adenine dinucleotide, nicotinamide and pyridoxal in human milk

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...

  14. Comparison of two column characterisation systems based on pharmaceutical applications.

    PubMed

    Haghedooren, Erik; Németh, Tamás; Dragovic, Sanja; Noszál, Béla; Hoogmartens, Jos; Adams, Erwin

    2008-05-02

    A useful column characterisation system should help chromatographers to select the most appropriate column to use, e.g. when a particular chromatographic column is not available or when facing the dilemma of selecting a suitable column for analysis according to an official monograph. Official monographs of the European Pharmacopoeia and the United States Pharmacopeia are not allowed to mention the brand name of the stationary phase used for the method development. Also given the overwhelming offer of several hundreds of commercially available reversed-phase liquid chromatographic columns, the choice of a suitable column could be difficult sometimes. To support rational column selection, a column characterisation study was started in our laboratory in 2000. In the same period, Euerby et al. also developed a column characterisation system, which is now released as Column Selector by ACD/Labs. The aim of this project was to compare the two existing column characterisation systems, i.e. the KUL system and the Euerby system. Other research groups active in this field will not be discussed here. Euerby et al. developed a column characterisation system based on 6 test parameters, while the KUL system is based on 4 chromatographic parameters. Comparison was done using a set of 63 columns. For 7 different pharmaceutical separations (fluoxetine, gemcitabine, erythromycin, tetracycline, tetracaine, amlodipine and bisacodyl), a ranking was built based on an F-value (KUL method) or Column Difference Factor value (Euerby method) versus a (virtual) reference column. Both methods showed a similar ranking. The KUL and Euerby methods do not perfectly match, but they yield very similar results, allowing with a relatively high certainty, the selection of similar or dissimilar columns as compared to a reference column. An analyst that uses either of the two methods, will end up with a similar ranking. From a practical point of view, it must be noted that the KUL method only includes 4

  15. Heat Transfer Analysis for a Fixed CST Column

    SciTech Connect

    Lee, S.Y.

    2004-02-19

    In support of a small column ion exchange (SCIX) process for the Savannah River Site waste processing program, a transient two-dimensional heat transfer model that includes the conduction process neglecting the convection cooling mechanism inside the crystalline silicotitanate (CST) column has been constructed and heat transfer calculations made for the present design configurations. For this situation, a no process flow condition through the column was assumed as one of the reference conditions for the simulation of a loss-of-flow accident. A series of the modeling calculations has been performed using a computational heat transfer approach. Results for the baseline model indicate that transit times to reach 130 degrees Celsius maximum temperature of the CST-salt solution column are about 96 hours when the 20-in CST column with 300 Ci/liter heat generation source and 25 degrees Celsius initial column temperature is cooled by natural convection of external air as a primary heat transfer mechanism. The modeling results for the 28-in column equipped with water jacket systems on the external wall surface of the column and water coolant pipe at the center of the CST column demonstrate that the column loaded with 300 Ci/liter heat source can be maintained non-boiling indefinitely. Sensitivity calculations for several alternate column sizes, heat loads of the packed column, engineered cooling systems, and various ambient conditions at the exterior wall of the column have been performed under the reference conditions of the CST-salt solution to assess the impact of those parameters on the peak temperatures of the packed column for a given transient time. The results indicate that a water-coolant pipe at the center of the CST column filled with salt solution is the most effective one among the potential design parameters related to the thermal energy dissipation of decay heat load. It is noted that the cooling mechanism at the wall boundary of the column has significant

  16. Enhanced reductive dechlorination in columns treated with edible oil emulsion

    NASA Astrophysics Data System (ADS)

    Long, Cameron M.; Borden, Robert C.

    2006-09-01

    The effect of edible oil emulsion treatment on enhanced reductive dechlorination was evaluated in a 14 month laboratory column study. Experimental treatments included: (1) emulsified soybean oil and dilute HCl to inhibit biological activity; (2) emulsified oil only; (3) emulsified oil and anaerobic digester sludge; and (4) continuously feeding soluble substrate. A single application of emulsified oil was effective in generating strongly reducing, anaerobic conditions for over 14 months. PCE was rapidly reduced to cis-DCE in all three live columns. Bioaugmentation with a halorespiring enrichment culture resulted in complete dechlorination of PCE to ethene in the soluble substrate column (yeast extract and lactate). However, an additional treatment with a pulse of yeast extract and bioaugmentation culture was required to stimulate complete dechlorination in the emulsion treated columns. Once the dechlorinating population was established, the emulsion only column degraded PCE from 90-120 μM to below detection with concurrent ethene production in a 33 day contact time. The lower biodegradation rates in the emulsion treated columns compared to the soluble substrate column suggest that emulsified oil barriers may require a somewhat longer contact time for effective treatment. In the HCl inhibited column, partitioning of PCE to the retained oil substantially delayed PCE breakthrough. However, reduction of PCE to more soluble degradation products ( cis-DCE, VC and ethene) greatly reduced the impact of oil-water partitioning in live columns. There was only a small decline in the hydraulic conductivity ( K) of column #1 (low pH + emulsion, Kfinal/ Kinitial = 0.57) and column #2 (live + emulsion, Kfinal/ Kinitial = 0.73) indicating emulsion injection did not result in appreciable clogging of the clayey sand. However, K loss was greater in column #3 (sludge +emulsion, Kfinal/ Kinitial = 0.12) and column #4 (soluble substrate, Kfinal/ Kinitial = 0.03) indicating clogging due

  17. The vertebral column of Australopithecus sediba.

    PubMed

    Williams, Scott A; Ostrofsky, Kelly R; Frater, Nakita; Churchill, Steven E; Schmid, Peter; Berger, Lee R

    2013-04-12

    Two partial vertebral columns of Australopithecus sediba grant insight into aspects of early hominin spinal mobility, lumbar curvature, vertebral formula, and transitional vertebra position. Au. sediba likely possessed five non-rib-bearing lumbar vertebrae and five sacral elements, the same configuration that occurs modally in modern humans. This finding contrasts with other interpretations of early hominin regional vertebral numbers. Importantly, the transitional vertebra is distinct from and above the last rib-bearing vertebra in Au. sediba, resulting in a functionally longer lower back. This configuration, along with a strongly wedged last lumbar vertebra and other indicators of lordotic posture, would have contributed to a highly flexible spine that is derived compared with earlier members of the genus Australopithecus and similar to that of the Nariokotome Homo erectus skeleton.

  18. The flotation column as a froth separator

    SciTech Connect

    Schultz, C.W.; Mehta, R.K.; Bates, J.B. )

    1991-12-01

    The Mineral Resources Institute, The University of Alabama, has for the past three years been engaged in a program to develop a beneficiation system for eastern (Devonian) oil shales. One objective of that program was to evaluate advanced technologies for effecting a kerogen-mineral matter separation. Column flotation was among the advanced technologies selected for evaluation. One observation made in the course of optimization testing was that introducing the feed into the froth (above the pulp- froth interface) resulted in an improved combination of concentrate grade and kerogen recovery. This observation was reported in a previous paper. Because the practice of maintaining the pulp froth interface below the feed point is contrary to conventional practice, it was decided to subject the observation to a systematic series of tests. This paper describes a recent series of tests and the results that were obtained.

  19. Optimization of monolithic columns for microfluidic devices

    NASA Astrophysics Data System (ADS)

    Pagaduan, Jayson V.; Yang, Weichun; Woolley, Adam T.

    2011-06-01

    Monolithic columns offer advantages as solid-phase extractors because they offer high surface area that can be tailored to a specific function, fast mass transport, and ease of fabrication. Porous glycidyl methacrylate-ethylene glycol dimethacrylate monoliths were polymerized in-situ in microfluidic devices, without pre-treatment of the poly(methyl methacrylate) channel surface. Cyclohexanol, 1-dodecanol and Tween 20 were used to control the pore size of the monoliths. The epoxy groups on the monolith surface can be utilized to immobilize target-specific probes such as antibodies, aptamers, or DNA for biomarker detection. Microfluidic devices integrated with solid-phase extractors should be useful for point-of-care diagnostics in detecting specific biomarkers from complex biological fluids.

  20. Dynamic CT scanning of spinal column trauma

    SciTech Connect

    Brown, B.M.; Brant-Zawadzki, M.; Cann, C.E.

    1982-12-01

    Dynamic sequential computed tomographic scanning with automatic table incrementation uses low milliampere-second technique to eliminate tube cooling delays between scanning slices and, thus, markedly shortens examination times. A total of 25 patients with spinal column trauma involving 28 levels were studied with dynamic scans and retrospectively reviewed. Dynamic studies were considerably faster than conventional spine examinations and yielded reliable diagnosis. Bone disruption and subluxation was accurately evaluated, and the use of intrathecal metrizamide in low doses allowed direct visualization of spinal cord or radicular compromise. Multiplanar image reformation was aided by the dynamic incrementation technique, since motion between slices (and the resulting misregistration artifact on image reformation) was minimized. A phantom was devised to test spatial resolution of computed tomography for objects 1-3 mm in size and disclosed minimal differences for dynamic and conventional computed tomographic techniques in resolving medium-to-high-contrast objects.

  1. Ewing's sarcoma of the vertebral column

    SciTech Connect

    Pilepich, M.V.; Vietti, T.J.; Nesbit, M.E.; Tefft, M.; Kissane, J.; Burgert, O.; Pritchard, D.; Gehan, E.A.

    1981-01-01

    Twenty-two patients with vertebral primaries were registered in the Intergroup Ewing's Sarcoma Study between 1973 and 1977. The radiation doses to the primary tumors ranged between 3800 and 6200 rad. All patients received intensive combination chemotherapy. After a followup ranging between 14 and 62 months, 14 patients remained disease-free. All patients with primary tumor of the cervical and dorsal spine remained disease-free. Of eight patients with lesions in the distal spine, (sacrococcygeal region) six developed recurrence, in three a local recurrence was observed despite doses of 6000 rad or higher. Doses of 5000 rad or less (in addition to combination chemotherapy as used in the Intergroup Ewing's Study) appear adequate in controlling the primary tumors of the proximal segments of the spinal column.

  2. Rapid Column Extraction Methods for Urine

    SciTech Connect

    Maxwell, S.L. III

    2000-06-09

    A new fecal analysis method that dissolves plutonium oxide was developed at the Westinghouse Savannah River Site. Diphonix Resin (Eichrom Industries), is used to pre-concentrate the actinides from digested fecal samples. A rapid microwave digestion technique is used to remove the actinides from the Diphonix Resin, which effectively extracts plutonium and americium from acidic solutions containing hydrofluoric acid. After resin digestion, the plutonium and americium are recovered in a small volume of nitric acid that is loaded onto small extraction chromatography columns, TEVA Resin and TRU Resin (Eichrom Industries). The method enables complete dissolution of plutonium oxide and provides high recovery of plutonium and americium with good removal of thorium isotopes such as thorium-228.

  3. Micro-column plasma emission liquid chromatograph

    DOEpatents

    Gay, Don D.

    1984-01-01

    In a direct current plasma emission spectrometer for use in combination with a micro-column liquid chromatograph, an improved plasma source unit. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  4. Three-way analysis of the UPLC-PDA dataset for the multicomponent quantitation of hydrochlorothiazide and olmesartan medoxomil in tablets by parallel factor analysis and three-way partial least squares.

    PubMed

    Dinç, Erdal; Ertekin, Zehra Ceren

    2016-01-01

    An application of parallel factor analysis (PARAFAC) and three-way partial least squares (3W-PLS1) regression models to ultra-performance liquid chromatography-photodiode array detection (UPLC-PDA) data with co-eluted peaks in the same wavelength and time regions was described for the multicomponent quantitation of hydrochlorothiazide (HCT) and olmesartan medoxomil (OLM) in tablets. Three-way dataset of HCT and OLM in their binary mixtures containing telmisartan (IS) as an internal standard was recorded with a UPLC-PDA instrument. Firstly, the PARAFAC algorithm was applied for the decomposition of three-way UPLC-PDA data into the chromatographic, spectral and concentration profiles to quantify the concerned compounds. Secondly, 3W-PLS1 approach was subjected to the decomposition of a tensor consisting of three-way UPLC-PDA data into a set of triads to build 3W-PLS1 regression for the analysis of the same compounds in samples. For the proposed three-way analysis methods in the regression and prediction steps, the applicability and validity of PARAFAC and 3W-PLS1 models were checked by analyzing the synthetic mixture samples, inter-day and intra-day samples, and standard addition samples containing HCT and OLM. Two different three-way analysis methods, PARAFAC and 3W-PLS1, were successfully applied to the quantitative estimation of the solid dosage form containing HCT and OLM. Regression and prediction results provided from three-way analysis were compared with those obtained by traditional UPLC method.

  5. Dispersion characteristics in column flotation of fine coal

    SciTech Connect

    Peng, F.F.; Lili, L.

    1995-10-01

    The dispersion model of nonideal flow was applied to describe the hydrodynamic state within the flotation column. Residence time distribution (RTD) data of a laboratory flotation column were measured to determine the parameters of the model. The effects of operating variables and column geometry on the Peclet number which reflects the extent of axial dispersion were investigated and a semi-empirical expression of Pe was formulated. The dispersion model was validated for the column flotation of ultrafines coal. Under the conditions of sufficient aeration rate and frother addition, a good agreement between the measured recoveries and predicted data was obtained. The dispersion model with first-order flotation rate process of the flotation column developed in this study is useful in predicting the collection zone recovery of fine coal, and for the flotation column scale-up.

  6. Commercial applications of the packed column froth separator

    SciTech Connect

    Yang, D.C.; Mengxiong Guo; Xusin Shao; Zexue Du

    1993-12-31

    The packed column flotation technology is commercially proven in processing a variety of coal and mineral fines. It incorporates the packing design to overcome most of the problems encountered by conventional columns or open vessel type cells. The packing elements break up air bubbles through small tortuous passages and support an unlimited froth depth inside the column where nearly all separation takes place. Thus, the packed column is actually a froth separator. The first commercial packed column for coal application was installed at the Pingdingshan Mine, China in 1989. This unit (1.5 m ID {times} 7 m tall) has been used to recover clean coal ({approximately}6% ash) from the black water (10--15% ash) with 82--88% coal yield. The capacity of the unit is 10--12 TPH. Some modifications of the column are being considered to improve product quality and to simplify control strategy.

  7. Temperature-compensated 8-bit column driver for AMLCD

    NASA Astrophysics Data System (ADS)

    Dingwall, Andrew G. F.; Lin, Mark L.

    1995-06-01

    An all-digital, 5 V input, 50 Mhz bandwidth, 10-bit resolution, 128- column, AMLCD column driver IC has been designed and tested. The 10-bit design can enhance display definition over 6-bit nd 8-bit column drivers. Precision is realized with on-chip, switched-capacitor DACs plus transparently auto-offset-calibrated, opamp outputs. Increased resolution permits multiple 10-bit digital gamma remappings in EPROMs over temperature. Driver IC features include externally programmable number of output column, bi-directional digital data shifting, user- defined row/column/pixel/frame inversion, power management, timing control for daisy-chained column drivers, and digital bit inversion. The architecture uses fewer reference power supplies.

  8. Parallel array of independent thermostats for column separations

    DOEpatents

    Foret, Frantisek; Karger, Barry L.

    2005-08-16

    A thermostat array including an array of two or more capillary columns (10) or two or more channels in a microfabricated device is disclosed. A heat conductive material (12) surrounded each individual column or channel in array, each individual column or channel being thermally insulated from every other individual column or channel. One or more independently controlled heating or cooling elements (14) is positioned adjacent to individual columns or channels within the heat conductive material, each heating or cooling element being connected to a source of heating or cooling, and one or more independently controlled temperature sensing elements (16) is positioned adjacent to the individual columns or channels within the heat conductive material. Each temperature sensing element is connected to a temperature controller.

  9. Targeted toxicological screening for acidic, neutral and basic substances in postmortem and antemortem whole blood using simple protein precipitation and UPLC-HR-TOF-MS.

    PubMed

    Telving, Rasmus; Hasselstrøm, Jørgen Bo; Andreasen, Mette Findal

    2016-09-01

    A broad targeted screening method based on broadband collision-induced dissociation (bbCID) ultra-performance liquid chromatography high-resolution time-of-flight mass spectrometry (UPLC-HR-TOF-MS) was developed and evaluated for toxicological screening of whole blood samples. The acidic, neutral and basic substances covered by the method were identified in postmortem and antemortem whole blood samples from forensic autopsy cases, clinical forensic cases and driving under the influence of drugs (DUID) cases by a reverse target database search. The screening method covered 467 substances. Validation was performed on spiked whole blood samples and authentic postmortem and antemortem whole blood samples. For most of the basic drugs, the established cut-off limits were very low, ranging from 0.25ng/g to 50ng/g. The established cut-off limits for most neutral and acidic drugs, were in the range from 50ng/g to 500ng/g. Sample preparation was performed using simple protein precipitation of 300μL of whole blood with acetonitrile and methanol. Ten microliters of the reconstituted extract were injected and separated within a 13.5min UPLC gradient reverse-phase run. Positive electrospray ionization (ESI) was used to generate the ions in the m/z range of 50-1000. Fragment ions were generated by bbCID. Identification was based on retention time, accurate mass, fragment ion(s) and isotopic pattern. A very sensitive broad toxicological screening method using positive electrospray ionization UPLC-HR-TOF-MS was achieved in one injection. This method covered basic substances, substances traditionally analyzed in negative ESI (e.g., salicylic acid), small highly polar substances such as beta- and gamma-hydroxybutyric acid (BHB and GHB, respectively) and highly non-polar substances such as amiodarone. The new method was shown to combine high sensitivity with a very broad scope that has not previously been reported in toxicological whole blood screening when using only one injection.

  10. Development and validation of an UPLC-MS/MS method for the quantification of tamoxifen and its main metabolites in human scalp hair.

    PubMed

    Drooger, Jan C; Jager, Agnes; Lam, Mei-Ho; den Boer, Mathilda D; Sleijfer, Stefan; Mathijssen, Ron H J; de Bruijn, Peter

    2015-10-10

    The aim of this study was to validate an earlier developed high-performance highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for quantification of tamoxifen and its three main metabolites (N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen) in scalp hair. This non-invasive method might, by segmental analysis of hair, be useful in the determination of the concentration of drugs and its metabolites over time, which can be used to study a wide variety of clinical relevant questions. Hair samples (150-300 hair strands, cut as close to the scalp as possible from the posterior vertex region of the head) were collected from female patients taking tamoxifen 20mg daily (n=19). The analytes were extracted using a liquid-liquid extraction procedure with carbonate buffer at pH 8.8 and a mixture of n-hexane/isopropranol method, followed by UPLC-MS/MS chromatography, based on an earlier validated method. The calibration curves were linear in the range of 1.00-200 pmol for tamoxifen and N-desmethyl-tamoxifen, with lower limit of quantitation of 1.00 pmol and 0.100-20.0 pmol with lower limit of quantitation of 0.100 pmol for endoxifen and 4-hydroxy-tamoxifen. Assay performance was fair with a within-run and between-run variability less than 9.24 at the three quality control samples and less than 15.7 for the lower limit of quantitation. Importantly, a steep linear decline was observed from distal to proximal hair segments. Probably, this is due to UV exposure as we showed degradation of tamoxifen and its metabolites after exposure to UV-light. Furthermore, higher concentrations of tamoxifen were found in black hair samples compared to blond and brown hair samples. We conclude that measurement of the concentration of tamoxifen and its main metabolites in hair is possible, with the selective, sensitive, accurate and precise UPLC-MS/MS method. However, for tamoxifen, it seems not possible to determine

  11. Residual Strength of Blast Damaged Reinforced Concrete Columns

    DTIC Science & Technology

    2010-07-01

    both reinforced concrete columns and shear walls during seismic investigations [14]. 4.2.3. Effect of longitudinal reinforcement ratio As the...Residual strength of blast damaged reinforced concrete columns Xiaoli Bao, Bing Li* School of Civil and Environmental Engineering, Nanyang...DATES COVERED - 4. TITLE AND SUBTITLE Residual strength of blast damaged reinforced concrete columns 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c

  12. Communication Avoiding Rank Revealing QR Factorization with Column Pivoting

    DTIC Science & Technology

    2013-05-03

    parallel computer. Research performed in the recent years has shown that most of the classic algorithms in direct dense linear algebra transfer more...O(2n). A strong RRQR factorization is computed by performing first a QR factorization with column pivoting followed by additional swaps of columns...notation. At each node of the reduction tree, f(Aij) returns the first b columns obtained after performing (strong) RRQR of Aij . The input matrix Aij

  13. In-plant testing of microbubble column flotation

    SciTech Connect

    Luttrell, G.H.; Mankosa, M.J.; Adel, G.T.; Yoon, R.H.

    1990-01-01

    This report describes progress in two areas: advanced instrumentation and column installation. The project is working with both 30-inch and 8-foot columns for coal flotation. The paper describes installation of the instrument package, the control loops, and the data acquisition system. Under the second area of study, a test plan was developed for a parametric study of the 8-foot column operating conditions (feed flow rate, gas flow rate, wash water flow rate, and froth addition) that were determined to influence separation efficiency on the 30-inch column. Results to date are discussed. 7 refs., 4 tabs. (CK)

  14. Enhanced column flotation of fine and ultrafine coal

    SciTech Connect

    Slomka, B.J.; Buttermore, W.H.; Birlingmair, D.H.; Dawson, M.R.; Pollard, J.L.; Enustun, B.V.

    1992-01-01

    A 2-inch diameter, twenty-foot tall, glass laboratory flotation column was modified to incorporate digital control of critical operating parameters. Different column control strategies were explored including location of the froth interface, and manipulation of volumetric flow ratios. Column flotation tests were performed with both fine (-250[mu]m) and ultrafine (-5[mu]m) Pittsburgh seam coal. Both moisture- and ash-free (MAF) recovery, and ash rejection were improved when the partition of the column's liquid content into froth and tailings was directly controlled. MAF recovery and ash rejection were also enhanced by brief exposure of the coarser feed to pulsed sonic energy.

  15. Mini-columns for Conducting Breakthrough Experiments. Design and Construction

    SciTech Connect

    Dittrich, Timothy M.; Reimus, Paul William; Ware, Stuart Douglas

    2015-06-11

    Experiments with moderately and strongly sorbing radionuclides (i.e., U, Cs, Am) have shown that sorption between experimental solutions and traditional column materials must be accounted for to accurately determine stationary phase or porous media sorption properties (i.e., sorption site density, sorption site reaction rate coefficients, and partition coefficients or Kd values). This report details the materials and construction of mini-columns for use in breakthrough columns to allow for accurate measurement and modeling of sorption parameters. Material selection, construction techniques, wet packing of columns, tubing connections, and lessons learned are addressed.

  16. Monolithic capillary columns based on pentaerythritol tetraacrylate for peptide analysis

    NASA Astrophysics Data System (ADS)

    Kucherenko, E. V.; Melnik, D. M.; Korolev, A. A.; Kanateva, A. Yu.; Pirogov, A. V.; Kurganov, A. A.

    2015-09-01

    Monolythic medium-polar capillary columns based on pentaerythritol tetraacrylate were optimized for separation of peptides. The synthesis temperature and time, the fraction of monomer in the initial polymerization mixture, and the nature of alcohol contained in the complex porogen were chosen as optimization parameters. The highest efficiency was attained for columns obtained with 33 and 34% monomer at a polymerization time of 75 min and a temperature of 75°C. The columns with the optimum structure were effective in separation of a model mixture of five peptides. The sensitivity of the method was 200 ng of peptide per column.

  17. Stability of leaning column at Devils Tower National Monument, Wyoming

    USGS Publications Warehouse

    Harp, Edwin L.; Lindsay, Charles R.

    2006-01-01

    In response to reports from climbers that an 8-meter section (referred to as the leaning column) of the most popular climbing route on Devils Tower in northeastern Wyoming is now moving when being climbed, scientists from the U.S. Geological Survey inspected the site to determine the stability of the column and the underlying column that serves as a support pedestal. Evidence of a recent tensile spalling failure was observed on the pedestal surface immediately beneath the contact with the overlying leaning column. The spalling of a flake-shaped piece of the pedestal, probably due to the high stress concentration exerted by the weight of the leaning column along a linear contact with the pedestal, is likely causing the present movement of the leaning column. Although it is unlikely that climbers will dislodge the leaning column by their weight alone, the possibility exists that additional spalling failures may occur from the pedestal surface and further reduce the stability of the leaning column and result in its toppling. To facilitate detection of further spalling failures from the pedestal, its surface has been coated with a layer of paint. Any new failures from the pedestal could result in the leaning column toppling onto the climbing route or onto the section of the Tower trail below.

  18. Halo columns: new generation technology for high speed liquid chromatography.

    PubMed

    Ali, Imran; Gaitonde, Vinay D; Grahn, Anders

    2010-01-01

    Fast speed and high sample loading and the pressing demands of industries and researchers are compelling scientists and manufacturers to explore the new horizons in column technology. Recently, superficially porous silica particle columns are manufactured with some salient features such as super fast speed, sharp peaks, good sample loading, and low backpressure. The commercially available columns are Halo (Advanced Material Technology, Wilmington, DE), Express (Supelco, Bellefonte, PA), and Proshell 120 (Agilent, Santa Clara, CA). Halo columns are of C(8), C(18), RP Amide, and HILIC types with 2.7 microm over all diameters, 0.5 microm porous thick layers containing 90 A as pore diameter, and 150 m(2)/g surface area. These columns have been used for fast separation of low molecular weight compounds with some exception for large molecules such as protein, peptides, and DNA. The present article describes the importance of these state-of-the-art superficially porous silica particles based columns with special emphasis on Halo columns. The different aspects of these columns such as structures, mechanism of separations, applications, and comparison, with conventional columns have been discussed.

  19. 13. Detail showing canopy at southeast corner; note single column ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    13. Detail showing canopy at southeast corner; note single column supporting structure - Fort Hood, World War II Temporary Buildings, Cold Storage Building, Seventeenth Street, Killeen, Bell County, TX

  20. Boston Column Network: Compact Solar-Tracking Spectrometers and Differential Column Measurements

    NASA Astrophysics Data System (ADS)

    Chen, J.; Samra, J.; Gottlieb, E.; Budney, J.; Daube, C.; Daube, B. C.; Hase, F.; Gerbig, C.; Chance, K.; Wofsy, S. C.

    2014-12-01

    In urban environments, the surface concentration is influenced by both the dynamics of the planetary boundary layer (PBL) height and by emissions. Path-integrated measurements that integrate through the entire mixed layer are valuable complements to surface data, compatible with the scale of the atmospheric models and therefore help reduce the representation errors in data assimilation studies of surface emission rates. Here we present a ground-based column sensor network in metro Boston. The network extends the existing surface sensor network to the vertical dimension in order to help quantify the concentration gradients across a city using a differential strategy: by measuring the "total column" of greenhouse gases (CO2, CH4, H2O etc.) and pollutants (NO2, O3, CH2O etc.) simultaneously inside and upwind of the urban core. Each stationary network site has a Fourier transform infrared spectrometer (Bruker, EM27Sun), a UV-visible grating spectrometer (Pandora) and a LIDAR (Sigma Space, Mini MPL) to provide PBL height. Two EM27Sun Fourier transform spectrometers at fixed locations are complemented by our self-developed solar-tracking Fourier transform spectrometer (Nicolet) to be used as a mobile unit to acquire cross-sectional slices of total column burdens across the urban dome. In additional to O2, CO2, CH4, H2O measurements, this system is also capable of measuring CO and N2O. This compact, inexpensive instrument uses a diffuser as a part of the tracking optics, which results in a rugged and simplified system. A novel camera-based active tracking schema is developed: the sun image on the diffuser is always regulated to the same position to ensure an accurate tracking. In this paper we will show comparisons between the self-developed solar-tracking system and the commercial Bruker EM27Sun. In addition, initial data for the retrieved column concentrations in and outside of the Boston urban dome will be presented.

  1. Fluid Dynamic Experiments on Mush Column Magmatism

    NASA Astrophysics Data System (ADS)

    Flanagan-Brown, R. E.; Marsh, B. D.

    2001-05-01

    A vertically extensive stack of sills interconnected by pipe-like conduits extending from the mantle through the lithosphere and capped by a volcanic center is a magmatic mush column. At any instant at various locations it contains fractionated and primitive melts as pools of nearly crystal-free magma, pools of crystal-rich magma, thick beds of cumulates, open conduits, and conduits congested by cognate and wall debris. All boundaries of the system are sheathed by solidification fronts. With the wide range of local, characteristic length scales there is a commensurate range of solidification time scales. This creates a complicated series of resistances to magma flow and provides a variety of distinct local physical environments for the chemical modification of magma. The system is driven by over-pressure from the addition of new melt from below. The over-pressure propagates upward by moving magma which flushes conduits, disrupts cumulate beds, and pools or purges sills. A critical aspect of this process is the entrainment, transport, and deposition of crystals throughout the system. Picritic lavas charges with entrained (tramp) olivine of a wide compositional range erupted at many systems (e.g. Jan Mayen, Kilauea, Reunion, etc.) are the final expression of this process. That the size and abundance of these crystals is correlated with eruptive flux (Murata & Richter, AJS, 1966) suggests an important indicator of the overall dynamics of the mush column. A mush column of this basic nature is observed is observed in the McMurdo Dry Valleys region of Antarctica and is inferred beneath Hawaii and the ocean ridges. We have attempted to model this process by studying the entrainment, transport, and deposition of particles in a vertical stack of sills (Plexiglas tanks) connected by resistive conduits (check valves), over-pressured from the base, and open at the top. The system is about two meters in height with water and oil as fluids and particles with Reynolds numbers

  2. Determination of BPA, BPB, BPF, BADGE and BFDGE in canned energy drinks by molecularly imprinted polymer cleaning up and UPLC with fluorescence detection.

    PubMed

    Gallo, Pasquale; Di Marco Pisciottano, Ilaria; Esposito, Francesco; Fasano, Evelina; Scognamiglio, Gelsomina; Mita, Gustavo Damiano; Cirillo, Teresa

    2017-04-01

    A new method for simultaneous determination of five bisphenols in canned energy drinks by UPLC with fluorescence detection, after clean up on molecularly imprinted polymers, is herein described. The method was validated at two concentration levels, calculating trueness, repeatability and within-laboratory reproducibility, specificity, linearity of detector response, the limits of quantifications and the limits of detection for each bisphenol. The method is specific, reliable and very sensitive, allowing for determination of bisphenol F diglycidyl ether (BFDGE), bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol A diglycidyl ether (BADGE) down to 0.50ng/mL; it was employed to determine contamination levels from these bisphenols in forty energy drinks of different brands, collected from the market in Naples. BPA was detected in 17 out of 40 samples (42.5%); in some energy drinks also BPF, BADGE and BFDGE were determined.

  3. Tocochromanols composition in kernels recovered from different apricot varieties: RP-HPLC/FLD and RP-UPLC-ESI/MS(n) study.

    PubMed

    Górnaś, Paweł; Mišina, Inga; Grāvīte, Ilze; Soliven, Arianne; Kaufmane, Edīte; Segliņa, Dalija

    2015-01-01

    Composition of tocochromanols in kernels recovered from 16 different apricot varieties (Prunus armeniaca L.) was studied. Three tocopherol (T) homologues, namely α, γ and δ, were quantified in all tested samples by an RP-HPLC/FLD method. The γ-T was the main tocopherol homologue identified in apricot kernels and constituted approximately 93% of total detected tocopherols. The RP-UPLC-ESI/MS(n) method detected trace amounts of two tocotrienol homologues α and γ in the apricot kernels. The concentration of individual tocopherol homologues in kernels of different apricots varieties, expressed in mg/100 g dwb, was in the following range: 1.38-4.41 (α-T), 42.48-73.27 (γ-T) and 0.77-2.09 (δ-T). Moreover, the ratio between individual tocopherol homologues α:γ:δ was nearly constant in all varieties and amounted to approximately 2:39:1.

  4. An approach for simultaneous determination for geographical origins of Korean Panax ginseng by UPLC-QTOF/MS coupled with OPLS-DA models.

    PubMed

    Song, Hyuk-Hwan; Kim, Doo-Young; Woo, Soyeun; Lee, Hyeong-Kyu; Oh, Sei-Ryang

    2013-07-01

    Identification of the origins of Panax ginseng has been issued in Korea scientifically and economically. We describe a metabolomics approach used for discrimination and prediction of ginseng roots from different origins in Korea. The fresh ginseng roots from six ginseng cooperative associations (Gangwon, Gaeseong, Punggi, Chungbuk, Jeonbuk, and Anseong) were analyzed by UPLC-MS-based approach combined with orthogonal projections to latent structure-discriminant analysis multivariate analysis. The ginsengs from Gangwon and Gaeseong were easily differentiated. We further analyzed the metabolomics results in subgroups. Punggi, Chungbuk, Jeonbuk, and Anseong ginseng could be easily differentiated by the first two orthogonal components. As a validation of the discrimination model, we performed blind prediction tests of sample origins using an external test set. Our model predicted their geographical origins as 99.7% probability. The robust discriminatory power and statistical validity of our method suggest its general applicability for determining the origins of P. ginseng samples.

  5. Serum pharmacochemistry for tracking bioactive components by UPLC-Q-TOF-MS/MS combined chromatographic fingerprint for quality assessment of Sanziguben Granule.

    PubMed

    Zhang, Chenxue; Lian, Ruixin; Mahmoodurrahman, Mohammed; Lai, Sisi; Zhao, Zhongxiang; Yu, Yang

    2016-09-01

    To more reasonably and effectively control the quality of Sanziguben Granule, chromatographic fingerprinting and serum pharmacochemistry of this traditional Chinese medicine compound were performed. A comprehensive comparison and evaluation of 15 batches of Sanziguben Granule was successfully conducted by using high performance liquid chromatography (HPLC) fingerprint analysis. After administering a set amount of Sanziguben Granule orally to rats, blood samples were collected and tested 4 times at intervals of 30min, 1h, 2h, and 4h using UPLC-Q-TOF-MS/MS. The blood showed presence of gallic acid and corilagin indicating the pharmacological significance of these two chemical compounds. According to the result, above mentional chemical compounds were designated biomarkers for quality control of Sanziguben Granule. Therefore, a purposeful and efficient method for quality control of Sanziguben Granule was established in the present study.

  6. Numerical method for the estimation of column radial heterogeneity and of the actual column efficiency from tailing peak profiles.

    PubMed

    Miyabe, Kanji; Guiochon, Georges

    2011-01-01

    It is probably impossible to prepare high-performance liquid chromatography (HPLC) columns that have a completely homogeneous packing structure. Many reports in the literature show that the radial distributions of the mobile phase flow velocity and the local column efficiency are not flat, even in columns considered as good. A degree of radial heterogeneity seems to be a common property of all HPLC columns and an important source of peak tailing, which prevents the derivation of accurate information on chromatographic behavior from a straightforward analysis of elution peak profiles. This work reports on a numerical method developed to derive from recorded peak profiles the column efficiency at the column center, the degree of column radial heterogeneity, and the polynomial function that best represents the radial distributions of the flow velocity and the column efficiency. This numerical method was applied to two concrete examples of tailing peak profiles previously described. It was demonstrated that this numerical method is effective to estimate important parameters characterizing the radial heterogeneity of chromatographic columns.

  7. First Detection of Tetrodotoxin in Greek Shellfish by UPLC-MS/MS Potentially Linked to the Presence of the Dinoflagellate Prorocentrum minimum

    PubMed Central

    Vlamis, Aristidis; Katikou, Panagiota; Rodriguez, Ines; Rey, Verónica; Alfonso, Amparo; Papazachariou, Angelos; Zacharaki, Thetis; Botana, Ana M.; Botana, Luis M.

    2015-01-01

    During official shellfish control for the presence of marine biotoxins in Greece in year 2012, a series of unexplained positive mouse bioassays (MBA) for lipophilic toxins with nervous symptomatology prior to mice death was observed in mussels from Vistonikos Bay–Lagos, Rodopi. This atypical toxicity coincided with (a) absence or low levels of regulated and some non-regulated toxins in mussels and (b) the simultaneous presence of the potentially toxic microalgal species Prorocentrum minimum at levels up to 1.89 × 103 cells/L in the area’s seawater. Further analyses by different MBA protocols indicated that the unknown toxin was hydrophilic, whereas UPLC-MS/MS analyses revealed the presence of tetrodotoxins (TTXs) at levels up to 222.9 μg/kg. Reviewing of official control data from previous years (2006–2012) identified a number of sample cases with atypical positive to asymptomatic negative MBAs for lipophilic toxins in different Greek production areas, coinciding with periods of P. minimum blooms. UPLC-MS/MS analysis of retained sub-samples from these cases revealed that TTXs were already present in Greek shellfish since 2006, in concentrations ranging between 61.0 and 194.7 μg/kg. To our knowledge, this is the earliest reported detection of TTXs in European bivalve shellfish, while it is also the first work to indicate a possible link between presence of the toxic dinoflagellate P. minimum in seawater and that of TTXs in bivalves. Confirmed presence of TTX, a very heat-stable toxin, in filter-feeding mollusks of the Mediterranean Sea, even at lower levels to those inducing symptomatology to humans, indicates that this emerging risk should be seriously taken into account by the EU to protect the health of shellfish consumers. PMID:26008234

  8. Quantitative analysis of unconjugated and total bisphenol A in human urine using solid-phase extraction and UPLC-MS/MS: method implementation, method qualification and troubleshooting.

    PubMed

    Buscher, Brigitte; van de Lagemaat, Dick; Gries, Wolfgang; Beyer, Dieter; Markham, Dan A; Budinsky, Robert A; Dimond, Stephen S; Nath, Rajesh V; Snyder, Stephanie A; Hentges, Steven G

    2015-11-15

    The aim of the presented investigation was to document challenges encountered during implementation and qualification of a method for bisphenol A (BPA) analysis and to develop and discuss precautions taken to avoid and to monitor contamination with BPA during sample handling and analysis. Previously developed and published HPLC-MS/MS methods for the determination of unconjugated BPA (Markham et al. Journal of Analytical Toxicology, 34 (2010) 293-303) [17] and total BPA (Markham et al. Journal of Analytical Toxicology, 38 (2014) 194-203) [20] in human urine were combined and transferred into another laboratory. The initial method for unconjugated BPA was developed and evaluated in two independent laboratories simultaneously. The second method for total BPA was developed and evaluated in one of these laboratories to conserve resources. Accurate analysis of BPA at sub-ppb levels is a challenging task as BPA is a widely used material and is ubiquitous in the environment at trace concentrations. Propensity for contamination of biological samples with BPA is reported in the literature during sample collection, storage, and/or analysis. Contamination by trace levels of BPA is so pervasive that even with extraordinary care, it is difficult to completely exclude the introduction of BPA into biological samples and, consequently, contamination might have an impact on BPA biomonitoring data. The applied UPLC-MS/MS method was calibrated from 0.05 to 25ng/ml. The limit of quantification was 0.1ng/ml for unconjugated BPA and 0.2ng/ml for total BPA, respectively, in human urine. Finally, the method was applied to urine samples derived from 20 volunteers. Overall, BPA can be analyzed in human urine with acceptable recovery and repeatability if sufficient measures are taken to avoid contamination throughout the procedure from sample collection until UPLC-MS/MS analysis.

  9. UPLC-QTOF analysis reveals metabolomic changes in the flag leaf of wheat (Triticum aestivum L.) under low-nitrogen stress.

    PubMed

    Zhang, Yang; Ma, Xin-Ming; Wang, Xiao-Chun; Liu, Ji-Hong; Huang, Bing-Yan; Guo, Xiao-Yang; Xiong, Shu-Ping; La, Gui-Xiao

    2017-02-01

    Wheat is one of the most important grain crop plants worldwide. Nitrogen (N) is an essential macronutrient for the growth and development of wheat and exerts a marked influence on its metabolites. To investigate the influence of low nitrogen stress on various metabolites of the flag leaf of wheat (Triticum aestivum L.), a metabolomic analysis of two wheat cultivars under different induced nitrogen levels was conducted during two important growth periods based on large-scale untargeted metabolomic analysis using ultra-performance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QTOF). Multivariate analyses-such as principle components analysis (PCA) and orthogonal partial least square discriminant analysis (OPLS-DA)-were used for data analysis. PCA yielded distinctive clustering information among the samples, classifying the wheat flag samples into two categories: those under normal N treatment and low N treatment. By processing OPLS-DA, eleven secondary metabolites were shown to be responsible for classifying the two groups. The secondary metabolites may be considered potential biomarkers of low nitrogen stress. Chemical analyses showed that most of the identified secondary metabolites were flavonoids and their related derivatives, such as iso-vitexin, iso-orientin and methylisoorientin-2″-O-rhamnoside, etc. This study confirmed the effect of low nitrogen stress on the metabolism of wheat, and revealed that the accumulation of secondary metabolites is a response to abiotic stresses. Meanwhile, we aimed to identify markers which could be used to monitor the nitrogen status of wheat crops, presumably to guide appropriate fertilization regimens. Furthermore, the UPLC-QTOF metabolic platform technology can be used to study metabolomic variations of wheat under abiotic stresses.

  10. Using UPLC-QTOF-MS to analyze the chemical changes between traditional and dispensing granule decoctions of San-Ao-Tang.

    PubMed

    Ma, Chunhua; Qian, Yefei; Fan, Xinsheng; Shang, ErXin; Yao, Xin; Ma, Shiping

    2014-04-01

    In the present study, a chemical profiling approach based on ultra-performance liquid chromatography coupled with photodiode array detection and time-of-flight mass spectrometry (UPLC-PDA-TOF-MS) was proposed to rapidly evaluate the chemical consistency between traditional and dispensing granule decoctions of traditional medicine combinatorial formulae and validated using San-Ao-Tang (SAT) as a model combinatorial formula. SAT is an effective traditional Chinese medicine, which is usually used in treating asthma and other diseases of the respiratory system. Two decoctions were prepared: traditional decoction, which is a water extract of three mixed constituent herbs of SAT; and dispensing granule decoction, which is a mixed water extract of each individual herb of SAT. Batches of these two decoction samples were subjected to UPLC-PDA-TOF-MS analysis and the data sets of t(R)-m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis to holistically compare their differences. Once a clear classification trend was found in the score plot, further statistics were performed to generate points at the two ends of S, and the components that correlated to these ions were regarded as the most changed components during decoction of the combinatorial formula. The changed components were identified by comparing the mass/ultraviolet spectra and retention times with those of reference compounds and/or tentatively assigned by matching empirical molecular formulae with those of the known compounds published in the literature. Using the proposed approach, global chemical differences were found between traditional and dispensing granule decoctions, like ephedrine, pseudoephedrine, norpseudoephedrine, licorice saponine H2, licorice saponine G2 and amygdalin.

  11. Evidence of non-extractable florfenicol residues: development and validation of a confirmatory method for total florfenicol content in kidney by UPLC-MS/MS.

    PubMed

    Faulkner, Dermot; Cantley, Margaret; Walker, Matthew; Crooks, Steven; Kennedy, David; Elliott, Christopher

    2016-06-01

    The parent compound florfenicol (FF) is a broad-spectrum antibacterial compound licensed in the UK for use in cattle, pigs and the aquaculture industry. The analysis of porcine tissues in this study demonstrates that significant amounts of solvent non-extractable FF-related residues are present in incurred tissues (kidney and muscle) from treated animals. The results indicate that methods based on solvent extraction alone may carry a significant risk of reporting false-negative results. The use of a strong acid hydrolysis step prior to solvent extraction of tissue samples is necessary for an accurate estimate of the total tissue FF content. A robust and sensitive method for the determination of total FF residue content in kidney samples by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed and validated. This method covers the synthetic amphenicol drug FF and its metabolites, measured as the marker residue florfenicol amine (FFA) as per Commission Regulation (EU) No. 37/2010. Non-extractable and intermediate metabolites are converted to the hydrolysis product FFA, and then partitioned into ethyl acetate. Extracts are solvent exchanged prior to a dispersive solid-phase extraction step, then analysed using an alkaline reverse-phase gradient separation by UPLC-MS/MS. The method was validated around the maximum residue levels (MRLs) set out in Regulation (EU) No. 37/2010 for bovine kidney in accordance with Commission Decision No. 2002/657/EC. The following method performance characteristics were assessed during a single laboratory validation study: selectivity, specificity, sensitivity, linearity, matrix effects, accuracy and precision (decision limit (CCα) and detection capability (CCβ) were determined).

  12. Seismogenic frictional melting in the magmatic column

    NASA Astrophysics Data System (ADS)

    Kendrick, J. E.; Lavallée, Y.; Hess, K.-U.; De Angelis, S.; Ferk, A.; Gaunt, H. E.; Meredith, P. G.; Dingwell, D. B.; Leonhardt, R.

    2014-04-01

    Lava dome eruptions subjected to high extrusion rates commonly evolve from endogenous to exogenous growth and limits to their structural stability hold catastrophic potential as explosive eruption triggers. In the conduit, strain localisation in magma, accompanied by seismogenic failure, marks the onset of brittle magma ascent dynamics. The rock record of exogenous dome structures preserves vestiges of cataclastic processes and thermal anomalies, key to unravelling subsurface processes. Here, a combined structural, thermal and magnetic investigation of a shear band crosscutting a large block erupted in 2010 at Soufrière Hills volcano (SHV) reveals evidence of faulting and frictional melting within the magmatic column. The mineralogy of this pseudotachylyte vein offers confirmation of complete recrystallisation, altering the structure, porosity and permeability of the material, and the magnetic signature typifies local electric currents in faults. Such melting events may be linked to the step-wise extrusion of magma accompanied by repetitive long-period (LP) drumbeat seismicity at SHV. Frictional melting of Soufrière Hills andesite in a high velocity rotary shear apparatus highlights the small slip distances (< 15 cm) thought to be required to bring 800 °C magma to melting point at upper conduit stress conditions (10 MPa). We conclude that frictional melting is a common consequence of seismogenic magma fracture during dome building eruptions and that it may govern the ascent of magma in the upper conduit.

  13. Seismogenic frictional melting in the magmatic column

    NASA Astrophysics Data System (ADS)

    Kendrick, J. E.; Lavallée, Y.; Hess, K.-U.; De Angelis, S.; Ferk, A.; Gaunt, H. E.; Dingwell, D. B.; Leonhardt, R.

    2013-10-01

    Lava dome eruptions subjected to high extrusion rates commonly evolve from endogenous to exogenous growth and limits to their structural stability hold catastrophic potential as explosive eruption triggers. In the conduit, strain localisation in magma, accompanied by seismogenic failure, marks the onset of brittle magma ascent dynamics. The rock record of exogenous dome structures preserves vestiges of cataclastic processes (Cashman et al., 2008; Kennedy and Russell, 2011) and of thermal anomalies (Kendrick et al., 2012), key to unravelling subsurface processes. Here, a combined structural, thermal and magnetic investigation of a shear band crosscutting a large block erupted in 2010 at Soufrière Hills volcano (SHV) reveals evidence of faulting and frictional melting within the magmatic column. The mineralogy of this pseudotachylyte vein offers confirmation of complete recrystallisation with an isothermal remanent magnetisation signature that typifies local electric currents in faults. The pseudotachylyte presents an impermeable barrier, which is thought to have influenced the degassing pathway. Such melting events may be linked to the step-wise extrusion of magma accompanied by repetitive long-period (LP) drumbeat seismicity at SHV (Neuberg et al., 2006). Frictional melting of SHV andesite in a high velocity rotary shear apparatus highlights the small slip distances (< 15 cm) required to bring 800 °C magma to melting point at upper conduit stress conditions (10 MPa). We conclude that frictional melting is an inevitable consequence of seismogenic, conduit-dwelling magma fracture during dome building eruptions and that it may have an important influence on magma ascent dynamics.

  14. Stirring a slightly magnetized column of plasma

    NASA Astrophysics Data System (ADS)

    Désangles, Victor; Bousselin, Guillaume; Poyé, Alexandre; Moulin, Marc; de Poucques, Ludovic; Plihon, Nicolas; Physique statistique, Hydrodynamique, Non-Linéarités Team; Département Chimie et Physique des Solides et des Surfaces Team

    2016-10-01

    The von-Kàrmàn plasma experiment (VKP) is a cylindrical, low pressure, high density plasma experiment which confines the plasma thanks to an axial magnetic field. Currents are radially driven between a hot emissive cathode and an anode which apply a Lorentz force on the plasma together with the magnetic field. We demonstrate that current driven radially sets the plasma into rotation. LIF technique at 668.43 nm as well as Mach probes measurements have been developed and used in different regimes in order to measure the velocity of plasma and relate it to the current driven between the electrodes. The LIF signal shows an important widening which corresponds to doppler shift effect due to the velocity of the ions. This widening can be related to the Mach probes signals. In the long term views, each end of the plasma column will be rotating in an opposite direction, such as to create a large shear-layer, resulting in a von-Kàrmàn-type flow.

  15. Kelvin waves in total column ozone

    NASA Astrophysics Data System (ADS)

    Ziemke, J. R.; Stanford, J. L.

    1994-01-01

    Tropical Kelvin waves have been observed previously in ozone mixing ratio data from the SBUV (Solar Backscatter Ultraviolet) and LIMS (Limb Infrared Monitor of the Stratosphere) instruments on board the Nimbus-7 satellite. The present study investigates Kelvin wave features in total column ozone, using version 6 data from the Total Ozone Mapping Spectrometer (TOMS) instrument (also on Nimbus-7). Results show eastward-propagating zonal waves 1-2 with periods approx. 5-15 days, amplitudes approx. 3-5 Dobson Units (1-2% of the time mean), and latitudinal symmetry typical of Kelvin waves. The analyses and a linear model in this study suggest that the primary source of the perturbations is slow Kelvin waves in the lower-to-middle stratosphere. Maximum Kelvin wave signatures occur in conjunction with westward lower-to-middle stratospheric equatorial zonal winds (a quasi-biennial oscillation (QBO) wind modulation effect). The significance of these results is that the TOMS data are shown to be useful for investigations with global coverage of a major component of tropical stratospheric dynamics, Kelvin waves. The TOMS data set with its excellent coverage and high quality should be useful in validating model studies in the relatively data sparse and dynamically difficult tropical region.

  16. SPR Hydrostatic Column Model Verification and Validation.

    SciTech Connect

    Bettin, Giorgia; Lord, David; Rudeen, David Keith

    2015-10-01

    A Hydrostatic Column Model (HCM) was developed to help differentiate between normal "tight" well behavior and small-leak behavior under nitrogen for testing the pressure integrity of crude oil storage wells at the U.S. Strategic Petroleum Reserve. This effort was motivated by steady, yet distinct, pressure behavior of a series of Big Hill caverns that have been placed under nitrogen for extended period of time. This report describes the HCM model, its functional requirements, the model structure and the verification and validation process. Different modes of operation are also described, which illustrate how the software can be used to model extended nitrogen monitoring and Mechanical Integrity Tests by predicting wellhead pressures along with nitrogen interface movements. Model verification has shown that the program runs correctly and it is implemented as intended. The cavern BH101 long term nitrogen test was used to validate the model which showed very good agreement with measured data. This supports the claim that the model is, in fact, capturing the relevant physical phenomena and can be used to make accurate predictions of both wellhead pressure and interface movements.

  17. Chain/column evolution and corresponding electrorheological effect

    NASA Astrophysics Data System (ADS)

    Wen, Weijia; Zheng, D. W.; Tu, K. N.

    1999-01-01

    We present an investigation about chain/column evolution and the corresponding electrorheological (ER) effect performed with glass/oil ER fluid. Our results demonstrate that once the field applied to the ER fluids surpasses a certain time period, the particles begin aggregating to form chains. These chains then coarsen and eventually form columns in the direction of the external field. We found that different column structures can be obtained depending on how the electric field is applied to the ER fluid. Only a loose column structure can be achieved if a square pulse field is applied to the ER fluid, yet a compact column is formed when the field strength is increased slowly. We have measured the ER effect with a sensitive yield stress testing device as the structure varies. The results indicate that there exist three increasing tendencies of interaction among particles corresponding to three processes of sequential transition between states; they are (1) random spatial configuration to chain, (2) chain to metastable column, and (3) metastable column to stable column.

  18. COLUMN EXPERIMENTS AND ANOMALOUS CONDUCTIVITY IN HYDROCARBON-IMPACTED SOILS

    EPA Science Inventory

    A laboratory experiment was designed to increase the understanding of the geoelectric effects of microbial " degradation of hydrocarbons. Eight large columns were were paired to provide a replicate of each of four experiments. These large-volume columns contained "sterilized" soi...

  19. 46 CFR 174.085 - Flooding on column stabilized units.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the unit, and within 5 feet (1.5 meters) of an outer surface of a column or footing on the periphery... feet (1.5 meters) of the unit's waterline before damage causing flooding must be assumed to be subject... distance between the vertical watertight bulkheads, measured at the column periphery, is equal to or...

  20. Taxicab Correspondence Analysis of Contingency Tables with One Heavyweight Column

    ERIC Educational Resources Information Center

    Choulakian, V.

    2008-01-01

    The aim of this paper is to study the analysis of contingency tables with one heavyweight column or one heavyweight entry by taxicab correspondence analysis (TCA). Given that the mathematics of TCA is simpler than the mathematics of correspondence analysis (CA), the influence of one heavyweight column on the outputs of TCA is studied explicitly…

  1. Exploring the Sulfur Nutrient Cycle Using the Winogradsky Column

    ERIC Educational Resources Information Center

    Rogan, Brian; Lemke, Michael; Levandowsky, Michael; Gorrell, Thomas

    2005-01-01

    The Winogradsky column demonstrates how the metabolic diversity of prokaryotes transforms sulfur to different forms with varying redox states and hence, supplies nutrients and/or energy to the organism. The Winogardsky column is an excellent way to show that not all bacteria are pathogens and they have an important role in the geochemical cycling…

  2. Stationary phases for packed-column supercritical fluid chromatography.

    PubMed

    Poole, Colin F

    2012-08-10

    The properties of silica-based, chemically bonded, packed column stationary phases used in supercritical fluid chromatography are described with a focus on column design and retention mechanisms. Supercritical fluid chromatography has benefited substantially from innovations in column design for liquid chromatography even if the separation conditions employed are generally quite different. The mobile phase composition and column operating conditions play an interactive role in modifying selectivity in supercritical fluid chromatography by altering analyte solubility in the mobile phase and through selective solvation of the stationary phase resulting in a wider range and intensity of intermolecular interactions with the analyte. The solvation parameter model is used to identify the main parameters that affect retention in supercritical fluid chromatography using carbon dioxide-methanol as a mobile phase and as a basis for column characterization to facilitate the identification of stationary phases with different separation characteristics for method development. As a caution it is pointed out that these column characterization methods are possibly a product of both the stationary phase chemistry and the column operating conditions and are suitable for use only when columns of similar design and with similar operating conditions are used.

  3. A Better Method for Filling Pasteur Pipet Chromatography Columns

    ERIC Educational Resources Information Center

    Ruekberg, Ben

    2006-01-01

    An alternative method for the preparation of Pasteur pipet chromatography columns is presented that allows the column to be filled with solvent without bubbles and allows greater control of fluid flow while the materials to be separated are added. Students are required to wear gloves and goggles and caution should be used while handling glass…

  4. An Automated Distillation Column for the Unit Operations Laboratory

    ERIC Educational Resources Information Center

    Perkins, Douglas M.; Bruce, David A.; Gooding, Charles H.; Butler, Justin T.

    2005-01-01

    A batch distillation apparatus has been designed and built for use in the undergraduate unit operations laboratory course. The column is fully automated and is accompanied by data acquisition and control software. A mixture of 1­-propanol and 2-­propanol is separated in the column, using either a constant distillate rate or constant composition…

  5. 29 CFR 1926.756 - Beams and columns.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) General. (1) During the final placing of solid web structural members, the load shall not be released from... bracing. Solid web structural members used as diagonal bracing shall be secured by at least one bolt per.... (c) (1) Double connections at columns and/or at beam webs over a column. When two structural...

  6. 29 CFR 1926.756 - Beams and columns.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) General. (1) During the final placing of solid web structural members, the load shall not be released from... bracing. Solid web structural members used as diagonal bracing shall be secured by at least one bolt per.... (c) (1) Double connections at columns and/or at beam webs over a column. When two structural...

  7. 29 CFR 1926.756 - Beams and columns.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) General. (1) During the final placing of solid web structural members, the load shall not be released from... bracing. Solid web structural members used as diagonal bracing shall be secured by at least one bolt per.... (c) (1) Double connections at columns and/or at beam webs over a column. When two structural...

  8. SURFACTANT ENHANCED REMEDIATION OF SOIL COLUMNS CONTAMINATED BY RESIDUAL TETRACHLOROETHYLENE

    EPA Science Inventory

    The ability of aqueous surfactant solutions to recover tetrachloroethylene (PCE) entrapped in Ottawa sand was evaluated in four column experiments. Residual PCE was emplaced by injecting 14C-labeled PCE into water-saturated soil columns and displacing the free product ...

  9. In-plant testing of microbubble column flotation

    SciTech Connect

    Luttrell, G.H.; Mankosa, M.J.; Adel, G.T.; Yoon, R.H.

    1991-01-01

    Testing of micro-bubble column flotation continued. Work during this time frame was concentrated on completion of the automated control and data acquisition system and the factorial test plan for evaluating the performance of the 8-foot column (Tasks 2.5 and 3.3). Preliminary results obtained from the factorial test program indicate that higher frother addition and aeration rates result in a higher separation efficiency. Furthermore, an increase in collector dosage results in higher column yields under most conditions. The Allen-Bradley PLC has been installed and program development completed for control of the 8-foot column. A completely automated start-up and shut-down sequence has been developed. This sequence can be initiated by the operator from a plant floor industrial interface. Instrumentation of the 30-inch column has also been completed. Testing of this instrumentation is currently underway. 11 figs., 5 tabs.

  10. Design, testing, and simulation of microscale gas chromatography columns

    SciTech Connect

    Hudson, M.L.; Kottenstette, R.; Matzke, C.M.; Frye-Mason, G.C.; Shollenberger, K.A.; Adkins, D.R.; Wong, C.C.

    1998-08-01

    A microscale gas chromatography column is one component in a microscale chemistry laboratory for detecting chemical agents. Several columns were fabricated using the Bosch etch process which allows deep, high aspect ratio channels of rectangular cross-section. A design tool, based on analytical models, was developed to evaluate the effects of operating conditions and column specifications on separation resolution and time. The effects of slip flow, channel configuration, and cross-sectional shape were included to evaluate the differences between conventional round, straight columns and the microscale rectangular, spiral columns. Experimental data were obtained and compared with the predicted flowrates and theoretical number of plates. The design tool was then employed to select more optimum channel dimensions and operating conditions for high resolution separations.

  11. Assessment of column selection systems using Partial Least Squares.

    PubMed

    Žuvela, Petar; Liu, J Jay; Plenis, Alina; Bączek, Tomasz

    2015-11-13

    Column selection systems based on calculation of a scalar measure based on Euclidean distance between chromatographic columns, suffer from the same issue. For diverse values of their parameters, identical or near-identical values can be calculated. Proper use of chemometric methods can not only provide a remedy, but also reveal underlying correlation between them. In this work, parameters of a well-established column selection system (CSS) developed at Katholieke Universiteit Leuven (KUL CSS) have been directly correlated to parameters of selectivity (retention time, resolution, and peak/valley ratio) toward pharmaceuticals, by employing Partial Least Squares (PLS). Two case studies were evaluated, separation of alfuzosin, lamotrigine, and their impurities, respectively. Within them, comprehensive correlation structure was revealed, which was thoroughly interpreted, confirming a causal relationship between KUL parameters and parameters of column performance. Furthermore, it was shown that the developed methodology can be applied to any distance-based column selection system.

  12. HEAT TRANSFER ANALYSIS FOR ION-EXCHANGE COLUMN SYSTEM

    SciTech Connect

    Lee, S.; King, W.

    2011-05-23

    Models have been developed to simulate the thermal characteristics of Crystalline Silicotitanate (CST) ion exchange media fully loaded with radioactive cesium in a column configuration and distributed within a waste storage tank. This work was conducted to support the Small Column Ion Exchange (SCIX) program which is focused on processing dissolved, high-sodium salt waste for the removal of specific radionuclides (including Cs-137, Sr-90, and actinides) within a High Level Waste (HLW) storage tank at the Savannah River Site. The SCIX design includes CST columns inserted and supported in the tank top risers for cesium removal. Temperature distributions and maximum temperatures across the column were calculated with a focus on process upset conditions. A two-dimensional computational modeling approach for the in-column ion-exchange domain was taken to include conservative, bounding estimates for key parameters such that the results would provide the maximum centerline temperatures achievable under the design configurations using a feed composition known to promote high cesium loading on CST. The current full-scale design for the CST column includes one central cooling pipe and four outer cooling tubes. Most calculations assumed that the fluid within the column was stagnant (i.e. no buoyancy-induced flow) for a conservative estimate. A primary objective of these calculations was to estimate temperature distributions across packed CST beds immersed in waste supernate or filled with dry air under various accident scenarios. Accident scenarios evaluated included loss of salt solution flow through the bed, inadvertent column drainage, and loss of active cooling in the column. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature.

  13. Applicability of ultra-performance liquid chromatography-tandem mass spectrometry for heroin profiling.

    PubMed

    Lurie, Ira S; Toske, Steven G

    2008-04-25

    The applicability of ultra- performance liquid chromatography tandem-mass spectrometry (UPLC-MS/MS) for heroin profiling is described. The coupling of the high separation power of UPLC with the highly selective and sensitive detection of MS/MS is well suited for heroin profiling. An Acquity UPLC BEH C18 1.7 microm particle column (100 mm x 2.1mm) with binary gradients containing 1% formic acid (pH 2.0) or 10 mM ammonium bicarbonate (pH 10.0)/acetonitrile mixtures was investigated for the profiling. For MS/MS detection, an atmospheric pressure positive electrospray source was employed with multiple reaction monitoring (MRM). MRMs for individual basic impurities were generated for heroin profiling using low and high pH mobile phases, while MRMs for neutral impurities were generated using a high pH mobile phase. Compared to a pH 2.2 mobile phase, the use of a pH 10 mobile phase allowed for significantly greater sample loading, major selectivity differences, and lower MRM sensitivity. UPLC-MS/MS allowed for the highly selective and sensitive detection of many of the targeted solutes in seized heroin exhibits. Basic impurities detected included morphine, codeine, noscapine, papaverine and the previously unreported solutes reticuline, reticuline monoacetate (2 products), reticuline diacetate, narceine, codamine, laudanidine, cryptopine, laudanosine, and norlaudanosine. Neutral impurities found included N,3,6-triacetylnormorphine, N-acetylnorcodeine, N-acetylnornarcotine, 3,6-dimethoxy-4-acetyloxy-5-[2-(N-methylacetamido)]-ethylphenanthrene, and cis-n-acetylanhydronornarceine. The detection of these impurities, at levels as low as 10(-6)% w/w should allow for greatly enhanced heroin profiles.

  14. Column Grid Array Rework for High Reliability

    NASA Technical Reports Server (NTRS)

    Mehta, Atul C.; Bodie, Charles C.

    2008-01-01

    Due to requirements for reduced size and weight, use of grid array packages in space applications has become common place. To meet the requirement of high reliability and high number of I/Os, ceramic column grid array packages (CCGA) were selected for major electronic components used in next MARS Rover mission (specifically high density Field Programmable Gate Arrays). ABSTRACT The probability of removal and replacement of these devices on the actual flight printed wiring board assemblies is deemed to be very high because of last minute discoveries in final test which will dictate changes in the firmware. The questions and challenges presented to the manufacturing organizations engaged in the production of high reliability electronic assemblies are, Is the reliability of the PWBA adversely affected by rework (removal and replacement) of the CGA package? and How many times can we rework the same board without destroying a pad or degrading the lifetime of the assembly? To answer these questions, the most complex printed wiring board assembly used by the project was chosen to be used as the test vehicle, the PWB was modified to provide a daisy chain pattern, and a number of bare PWB s were acquired to this modified design. Non-functional 624 pin CGA packages with internal daisy chained matching the pattern on the PWB were procured. The combination of the modified PWB and the daisy chained packages enables continuity measurements of every soldered contact during subsequent testing and thermal cycling. Several test vehicles boards were assembled, reworked and then thermal cycled to assess the reliability of the solder joints and board material including pads and traces near the CGA. The details of rework process and results of thermal cycling are presented in this paper.

  15. Novel techniques for slurry bubble column hydrodynamics

    SciTech Connect

    Dudukovic, M.P.

    1999-05-14

    The objective of this cooperative research effort between Washington University, Ohio State University and Exxon Research Engineering Company was to improve the knowledge base for scale-up and operation of slurry bubble column reactors for syngas conversion and other coal conversion processes by increased reliance on experimentally verified hydrodynamic models. During the first year (July 1, 1995--June 30, 1996) of this three year program novel experimental tools (computer aided radioactive particle tracking (CARPT), particle image velocimetry (PIV), heat probe, optical fiber probe and gamma ray tomography) were developed and tuned for measurement of pertinent hydrodynamic quantities, such as velocity field, holdup distribution, heat transfer and bubble size. The accomplishments were delineated in the First Technical Annual Report. The second year (July, 1996--June 30, 1997) was spent on further development and tuning of the novel experimental tools (e.g., development of Monte Carlo calibration for CARPT, optical probe development), building up the hydrodynamic data base using these tools and comparison of the two techniques (PIV and CARPT) for determination of liquid velocities. A phenomenological model for gas and liquid backmixing was also developed. All accomplishments were summarized in the Second Annual Technical Report. During the third and final year of the program (July 1, 1997--June 30, 1998) and during the nine months no cost extension, the high pressure facility was completed and a set of data was taken at high pressure conditions. Both PIV, CT and CARPT were used. More fundamental hydrodynamic modeling was also undertaken and model predictions were compared to data. The accomplishments for this period are summarized in this report.

  16. Static column and its industrial application in China

    SciTech Connect

    Lu, M.; Wang, F.; Liu, W.; Xu, E.; Xu, Q.

    1999-07-01

    The column, as an advanced fine coal cleaning equipment, has been developed for more than 20 years. The Microcel, Jameson cell and other types of columns have been used in the coal industry. Since 1990, the cyclonic micro-bubble flotation column has been developed. The test of 1.5 M packed column is underway in the Shitai coal preparation plant. Chinese fine coal is quite difficult to separate. Its native ash content is high and the floatability is difficult. There is not compressed air available in the small coal mine. The high cost for waste-water treatment limited the usage of wash water. It is necessary to study the column under Chinese conditions. Laboratory tests have been done for five coals. Conventional flotation tests were also done in a one-liter flotation cell in order to compare with the results of static column. Compared with a conventional flotation cell, lower ash content and higher combustion recovery are obtained from the static column. In addition, the static column can produce super-low-ash clean coal and treat very fine and high ash content slurry, which is difficult for conventional flotation cell to separate. Test results also show that the construction of the bubble generator and the aeration rate are important for the performance of the static column. An one-meter diameter by six-meter high FXZ-1 static column has been used in four coal preparation plants for more than one year. The results are satisfactory. An additional three columns with the diameter of 1 M and 1.25 M in another 3 coal mines have been fabricated and will be put into use soon. The three-meter column has been designed for MaTou coal preparation plant and is in the course of fabrication now. The static column does not need any high-pressure air and usually does not use wash-water. The power consumption is very low and manual operation is easy. The investment and operating cost is low. In addition, the separation results are quite satisfactory. It has been recommended to be

  17. Miniaturized ultra-high performance liquid chromatography coupled to electrochemical detection: Investigation of system performance for neurochemical analysis.

    PubMed

    Van Schoors, Jolien; Maes, Katrien; Van Wanseele, Yannick; Broeckhoven, Ken; Van Eeckhaut, Ann

    2016-01-04

    The interest in implementation of miniaturized ultra-high performance liquid chromatography (UHPLC) in neurochemical research is growing because of the need for faster, more selective and more sensitive neurotransmitter analyses. The instrument performance of a tailor designed microbore UHPLC system coupled to electrochemical detection (ECD) is investigated, focusing on the quantitative monoamine determination in in vivo microdialysis samples. The use of a microbore column (1.0mm I.D.) requires miniaturization of the entire instrument, though a balance between extra-column band broadening and injection volume must be considered. This is accomplished through the user defined Performance Optimizing Injection Sequence, whereby 5 μL sample is injected on the column with a measured extra-column variance of 4.5-9.0 μL(2) and only 7 μL sample uptake. Different sub-2 μm and superficially porous particle stationary phases are compared by means of the kinetic plot approach. Peak efficiencies of about 16000-35000 theoretical plates are obtained for the Acquity UPLC BEH C18 column within 13 min analysis time. Furthermore, the coupling to ECD is shown suitable for microbore UHPLC analysis thanks to the miniaturized flow cell design, sufficiently fast data acquisition and mathematical data filtering. Ultimately, injection of in vivo samples demonstrates the applicability of the system for microdialysis analysis.

  18. Miniature Distillation Column for Producing LOX From Air

    NASA Technical Reports Server (NTRS)

    Rozzi, Jay C.

    2006-01-01

    The figure shows components of a distillation column intended for use as part of a system that produces high-purity liquid oxygen (LOX) from air by distillation. (The column could be easily modified to produce high-purity liquid nitrogen.) Whereas typical industrial distillation columns for producing high-purity liquid oxygen and/or nitrogen are hundreds of feet tall, this distillation column is less than 3 ft (less than about 0.9 m) tall. This column was developed to trickle-charge a LOX-based emergency oxygen system (EOS) for a large commercial aircraft. A description of the industrial production of liquid oxygen and liquid nitrogen by distillation is prerequisite to a meaningful description of the present miniaturized distillation column. Typically, such industrial production takes place in a chemical processing plant in which large quantities of high-pressure air are expanded in a turboexpander to (1) recover a portion of the electrical power required to compress the air and (2) partially liquefy the air. The resulting two-phase flow of air is sent to the middle of a distillation column. The liquid phase is oxygen-rich, and its oxygen purity increases as it flows down the column. The vapor phase is nitrogen-rich and its nitrogen purity increases as it flows up the column. A heater or heat exchanger, commonly denoted a reboiler, is at the bottom of the column. The reboiler is so named because its role is to reboil some of the liquid oxygen collected at the bottom of the column to provide a flow of oxygen-rich vapor. As the oxygen-rich vapor flows up the column, it absorbs the nitrogen in the down-flowing liquid by mass transfer. Once the vapor leaves the lower portion of the column, it interacts with down-flowing nitrogen liquid that has been condensed in a heat exchanger, commonly denoted a condenser, at the top of the column. Liquid oxygen and liquid nitrogen products are obtained by draining some of the purified product at the bottom and top of the column

  19. Orientation and color columns in monkey visual cortex.

    PubMed

    Dow, Bruce M

    2002-10-01

    The literature on orientation and color columns in monkey visual cortex is reviewed. The orientation column model most consistent with existing data is one containing 'stripes' of alternating positive and negative orientation 'singularities' (cytochrome oxidase blobs) which run along the centers of ocular dominance (OD) columns, with horizontal and vertical orientations alternating at interblob centers. Evidence is summarized suggesting that color is mapped continuously across the monkey's primary visual cortex, with the ends of the spectrum located at 'red' and 'blue' cytochrome oxidase blobs and extra-spectral purple located between adjacent red and blue blobs in the same OD column. In the orientation column model, the 'linear zones' of Obermayer and Blasdel have the appearance of the lines on a pumpkin. A pinwheel model of color columns, consistent with existing data, includes spectral and extra-spectral colors as spokes. Spectral iso-color lines run across iso-orientation lines in linear zones, while extra-spectral iso-color lines occupy the 'saddle points' of Obermayer and Blasdel. The color column model accounts for closure of the perceptual color circle, as proposed by Isaac Newton in 1704, but does not account for color opponency.

  20. In-plant testing of microbubble column flotation

    SciTech Connect

    Yoon, R.H.; Luttrell, G.H.; Adel, G.T.

    1989-01-01

    A project to evaluate the performance of the Virginia Tech Microbubble Column Flotation (MCF) process in an operating coal preparation plant was initiated during this past quarter. The project is concerned with the collection of process operating data using a 30-inch diameter column, and using this data to scale-up to a prototype, full-scale plant column. The work is being carried out at the Marrowbone Preparation Plant owned by the Shell Mining Corporation. Work has primarily concentrated on finalizing the project work plan (Task 2.1 -- Project Planning), instrumenting the 30-inch diameter column (Task 2.2 -- Advanced Instrumentation) and conducting a preliminary parametric study to evaluate the performance of the column (Task 2.3 -- Detailed Testing). To date, the column has been consistently capable of producing a 9.5% ash product at a 61% combustible recovery from a -150 mesh classifying cyclone overflow containing 55--60% ash at 3--5% solids. Tests conducted over an extended period of time indicate that the column consistently maintains grade in spite of fluctuations in the feed characteristics. 12 figs.

  1. Weir plate stripping column for alcohol production. Final report

    SciTech Connect

    Ross, J.D.; Sharpe, S.

    1984-01-01

    This project consisted of the design, construction and test of a new concept for an alcohol stripping column. The concept involved the use of a series of dams and weirs in an inclined tube to produce the effects of plates in a conventional column. A secondary objective was to test the use of plastic as a construction material. It was felt that the concept would lead to a low cost system that would have application in small farm systems for the production of alcohol fuel. It was also felt that the stability of the system would be ideal for systems that would use solar power for a heat source. A plastic stripping tower containing 25 plates was tested on a beer from fermented corn meal. The column produced 140 proof alcohol, and in general, worked as expected. The relative low proof of the output and the lack of a steep gradient along the tube, indicated that the column is not as efficient as conventional columns. The test indicated that CPVC plastic could be used in the construction of a column; however, sealing problems and its cost make it questionable that the use of this type material would lead to a lower cost column. 7 figures.

  2. Sources of Variability in the Stratospheric Column of Nitrogen Dioxide

    NASA Technical Reports Server (NTRS)

    Douglass, Anne; Gleason, James; Chin, Mian; Einaudi, Franco (Technical Monitor)

    2001-01-01

    Instruments such as the Global Ozone Monitoring Experiment (GOME, on the European Remote Sensing Satellite (ERS-2), launched 1995), the Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY, on ENVISAT, to be launched July 2001) and the Ozone Monitoring Instrument (OMI on EOS Aura, to be launched 2003) make measurements of the total column of NO2. There is interest in separating the stratospheric and tropospheric contributions to the column, as the tropospheric column provides a measure of pollution. We are using a 3D chemistry and transport model driven by winds from the Goddard Space Flight Center Data Assimilation System to examine variability in the stratospheric NO2 column. Model results for NOx = NO + NO2 + 2N2O5 will be shown to compare well with sunset observations from the Halogen Occultation Experiment on the Upper Atmosphere Research Satellite, and to exhibit similar temporal and spatial dependence. Partitioning between NO, NO2, and N2O5 is also shown to compare well with observations. This good agreement supports the use of simulated fields in the stratosphere to derive the tropospheric column from the total column. Preliminary comparisons of the tropospheric column with model simulations for the troposphere will also be shown.

  3. Analysis of Cordyceps by multi-column liquid chromatography.

    PubMed

    Qian, Zhengming; Li, Shaoping

    2017-03-01

    Cordyceps is a famous traditional Chinese medicine (TCM) that has been used in China for hundreds of years. In the present study a multi-column liquid chromatography (MC-LC) system was developed for the qualitative analysis of macromolecules and micromolecules in Cordyceps. The MC-LC system includes a size exclusion pre-column, a size exclusion column (SEC) and a reversed phase column (RP) which were controlled by column-switching valves. The sample was separated by the size exclusion pre-column into two fractions (macromolecules and micromolecules). These fractions were further separated on SEC and RP columns, respectively. A diode array detector (DAD) and a mass spectrometer (MS) were used to detect the components. This MC-LC method was utilized for analysis of Cordyceps samples. Two macromolecular peaks and 15 micromolecular peaks were found in Cordyceps, and 11 of the micromolecular peaks were identified as adenosine-5'-monophosphate (AMP), phenylalanine, uridine, hypoxanthine, inosine, guanine, guanosine, deoxyadenosine-5'-monophosphate (dAMP), adenosine, adenine and cordycepin (or its isomer). This method is useful for quality control of Cordyceps.

  4. Investigation of Gas Holdup in a Vibrating Bubble Column

    NASA Astrophysics Data System (ADS)

    Mohagheghian, Shahrouz; Elbing, Brian

    2015-11-01

    Synthetic fuels are part of the solution to the world's energy crisis and climate change. Liquefaction of coal during the Fischer-Tropsch process in a bubble column reactor (BCR) is a key step in production of synthetic fuel. It is known from the 1960's that vibration improves mass transfer in bubble column. The current study experimentally investigates the effect that vibration frequency and amplitude has on gas holdup and bubble size distribution within a bubble column. Air (disperse phase) was injected into water (continuous phase) through a needle shape injector near the bottom of the column, which was open to atmospheric pressure. The air volumetric flow rate was measured with a variable area flow meter. Vibrations were generated with a custom-made shaker table, which oscillated the entire column with independently specified amplitude and frequency (0-30 Hz). Geometric dependencies can be investigated with four cast acrylic columns with aspect ratios ranging from 4.36 to 24, and injector needle internal diameters between 0.32 and 1.59 mm. The gas holdup within the column was measured with a flow visualization system, and a PIV system was used to measure phase velocities. Preliminary results for the non-vibrating and vibrating cases will be presented.

  5. Interpreting satellite column observations of formaldehyde over tropical South America.

    PubMed

    Palmer, Paul I; Barkley, Michael P; Kurosu, Thomas P; Lewis, Alastair C; Saxton, Julie E; Chance, Kelly; Gatti, Luciana V

    2007-07-15

    Space-borne column measurements of formaldehyde (HCHO), a high-yield oxidation product of volatile organic compounds (VOCs), represent important constraints for quantifying net regional fluxes of VOCs. Here, we interpret observed distributions of HCHO columns from the Global Ozone Monitoring Experiment (GOME) over tropical South America during 1997-2001. We present the first comparison of year-long in situ isoprene concentrations and fire-free GOME HCHO columns over a tropical ecosystem. GOME HCHO columns and in situ isoprene concentrations are elevated in the wet and dry seasons, with the highest values in the dry season. Previous analysis of the in situ data highlighted the possible role of drought in determining the elevated concentrations during the dry season, inferring the potential of HCHO columns to provide regional-scale constraints for estimating the role of drought on isoprene emissions. The agreement between the observed annual cycles of GOME HCHO columns and Along-Track Scanning Radiometer firecount data over the Amazon basin (correlations typically greater than 0.75 for a particular year) illustrates the potential of HCHO column to provide quantitative information about biomass burning emissions.

  6. Miniature electron microscope beam column optics

    NASA Astrophysics Data System (ADS)

    Loyd, Jody Stuart

    This investigation is in the area of electrostatic lens design with the overarching goal of contributing to the creation of a miniaturized scanning electron microscope (SEM) for use in mineralogical analysis or detection of signs of life on the surface of Mars. Such an instrument could also have application in the exploration of Earth's moon, planetary moons, asteroids, or comets. Other embodiments could include tabletop or field portable SEMs for use on Earth. The scope of this research is in the design of a beam column that attains focusing, demagnification, and aberration control within the smallest achievable package. The goals of planetary exploration and of spaceflight in general impose severe constraints on the instrument's mass and electrical power consumption, while favoring a robust design of small size and high rigidity that is also simple to align. To meet these requirements a design using electrostatic lenses was favored because of the lower power requirement and mass of electrostatic versus magnetic lenses, their relatively simple construction, as well as inherently easier shielding from extraneous fields. In modeling the lens field, a hybrid of a Boundary Element Method (BEM) and a Fourier series solution was employed, whereby an initial solution from the BEM is used to derive the bounding potential of a cylindrical subdomain for the subsequent Fourier series solution. The approach is applicable to many problems in physics and combines the inherent precision of this series solution with the flexibility of BEM to describe practical, non-idealized electrode shapes. The resulting lens field in the Fourier series subdomain is of higher precision, thereby allowing smaller errors in subsequent calculations of electron ray paths. The effects of aberrations are thus easier to observe in tracing non-paraxial rays. A significant speed increase in tracing rays is also observed. The modeling technique has been validated by reproducing example ray-traces through

  7. Separation of donor and recipient bacteria by column chromatography.

    PubMed

    Zsigray, R M; Fulk, G E; Lawton, W D

    1970-08-01

    When donor and recipient strains of Escherichia coli were added to columns containing Cellex-P (a cation-exchange cellulose), more than 80% of the female cells passed through the column but only 11% or less of the male cells were eluted. However, when donor strains were blended before their addition to the column, the majority of these cells were eluted. These results indicated that the filamentous appendages termed F pili (which are removed by blending) were the structures responsible for the adherence of donor cells to the cellulose.

  8. Buckling Instability of Self-Assembled Colloidal Columns

    NASA Astrophysics Data System (ADS)

    Swan, James W.; Vasquez, Paula A.; Furst, Eric M.

    2014-09-01

    Suspended, slender self-assembled domains of magnetically responsive colloids are observed to buckle in microgravity. Upon cessation of the magnetic field that drives their assembly, these columns expand axially and buckle laterally. This phenomenon resembles the buckling of long beams due to thermal expansion; however, linear stability analysis predicts that the colloidal columns are inherently susceptible to buckling because they are freely suspended in a Newtonian fluid. The dominant buckling wavelength increases linearly with column thickness and is quantitatively described using an elastohydrodynamic model and the suspension thermodynamic equation of state.

  9. Modeling Cooling Rates of Martian Flood Basalt Columns

    NASA Astrophysics Data System (ADS)

    Weiss, D. K.; Jackson, B.; Milazzo, M. P.; Barnes, J. W.

    2011-12-01

    Columnar jointing in large basalt flows have been extensively studied and can provide important clues about the emplacement conditions and cooling history of a basalt flow. The recent discovery of basalt columns on Mars in crater walls near Marte Vallis provides an opportunity to infer conditions on early Mars when the Martian basalt flows were laid down. Comparison of the Martian columns to Earth analogs allows us to gain further insight into the early Martian climate, and among the best terrestrial analogs are the basalt columns in the Columbia River Basalt Group (CRBG) in eastern Washington. The CRBG is one of the youngest (< 17 Myrs old) and most extensively studied basalt provinces in the world, extending over 163,700 square km with total thickness exceeding 1 km in some places. The morphologies and textures of CRBG basalt columns suggest that in many places flows ~100 m thick cooled at uniform rates, even deep in the flow interior. Such cooling seems to require the presence of water in the column joints since the flow interiors should have cooled much more slowly than the flow margins if conductive cooling dominated. Secondary features, such pillow basalts, likewise suggest the basalt flows were in direct contact with standing water in many places. At the resolution provided by the orbiting HiRISE camera (0.9 m), the Martian basalt columns resemble the CRBG columns in many respects, and so, subject to important caveats, inferences linking the morphologies of the CRBG columns to their thermal histories can be extended in some respects to the Martian columns. In this presentation, we will describe our analysis of the HiRISE images of the Martian columns and what can be reasonably inferred about their thermal histories and the conditions under which they were emplaced. We will also report on a field expedition to the CRBG in eastern Washington State. During that expedition, we surveyed basalt column outcrops on the ground and from the air using Unmanned Aerial

  10. MODELING AND SIMULATION OF SOLID FLUIDIZATION IN A RESIN COLUMN

    SciTech Connect

    Lee, S.

    2014-06-24

    The objective of the present work is to model the resin particles within the column during fluidization and sedimentation processes using computation fluid dynamics (CFD) approach. The calculated results will help interpret experimental results, and they will assist in providing guidance on specific details of testing design and establishing a basic understanding of particle’s hydraulic characteristics within the column. The model is benchmarked against the literature data and the test data (2003) conducted at Savannah River Site (SRS). The paper presents the benchmarking results and the modeling predictions of the SRS resin column using the improved literature correlations applicable for liquid-solid granular flow.

  11. SENSITIVITY ANALYSIS FOR SALTSTONE DISPOSAL UNIT COLUMN DEGRADATION ANALYSES

    SciTech Connect

    Flach, G.

    2014-10-28

    PORFLOW related analyses supporting a Sensitivity Analysis for Saltstone Disposal Unit (SDU) column degradation were performed. Previous analyses, Flach and Taylor 2014, used a model in which the SDU columns degraded in a piecewise manner from the top and bottom simultaneously. The current analyses employs a model in which all pieces of the column degrade at the same time. Information was extracted from the analyses which may be useful in determining the distribution of Tc-99 in the various SDUs throughout time and in determining flow balances for the SDUs.

  12. Differentiating organically and conventionally grown oregano using ultraperformance liquid chromatography mass spectrometry (UPLC-MS), headspace gas chromatography with flame ionization detection (headspace-GC-FID), and flow injection mass spectrum (FIMS) fingerprints combined with multivariate data analysis.

    PubMed

    Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy

    2014-08-13

    Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.

  13. Ion chromatographic separation of inorganic ions using a combination of hydrophilic interaction chromatographic column and cation-exchange resin column.

    PubMed

    Arai, Kaori; Mori, Masanobu; Hironaga, Takahiro; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2012-04-01

    A combination of hydrophilic interaction chromatographic (HILIC) column and a weakly acidic cation-exchange resin (WCX) column was used for simultaneous separation of inorganic anions and cations by ion chromatography (IC). Firstly, the capability of HILIC column for the separation of analyte ions was evaluated under acidic eluent conditions. The columns used were SeQuant ZIC-HILIC (ZIC-HILIC) with a sulfobetaine-zwitterion stationary phase (ZIC-HILIC) and Acclaim HILIC-10 with a diol stationary phase (HILIC-10). When using tartaric acid as the eluent, the HILIC columns indicated strong retentions for anions, based on ion-pair interaction. Especially, HILIC-10 could strongly retain anions compared with ZIC-HILIC. The selectivity for analyte anions of HILIC-10 with 5 mmol/L tartaric acid eluent was in the order of I(-) > NO3(-) > Br(-) > Cl(-) > H2PO4(-). However, since HILIC-10 could not separate analyte cations, a WCX column (TSKgel Super IC-A/C) was connected after the HILIC column in series. The combination column system of HILIC and WCX columns could successfully separate ten ions (Na+, NH4+, K+, Mg2+, Ca2+, H2PO4(-), Cl(-), Br(-), NO3(-) and I(-)) with elution of 4 mmol/L tartaric acid plus 8 mmol/L 18-crown-6. The relative standard deviations (RSDs) of analyte ions by the system were in the ranges of 0.02% - 0.05% in retention times and 0.18% - 5.3% in peak areas through three-time successive injections. The limits of detection at signal-to-noise ratio of 3 were 0.24 - 0.30 micromol/L for the cations and 0.31 - 1.2 micromol/L for the anions. This system was applied for the simultaneous determination of the cations and the anions in a vegetable juice sample with satisfactory results.

  14. East side, showing ruin of brownstone column capital that originally ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    East side, showing ruin of brownstone column capital that originally supported the east side portico, a feature that was destroyed in the 1886 earthquake - William Ravenel House, 13 East Battery Street, Charleston, Charleston County, SC

  15. 19. VIEW SOUTH, NORTH ELEVATION AT DOUBLE COLUMN CONCRETE EXPANSION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. VIEW SOUTH, NORTH ELEVATION AT DOUBLE COLUMN CONCRETE EXPANSION JOINT AT PIER NUMBER 112 - Route 1 Extension, South Street Viaduct, Spanning Conrail & Wheeler Point Road at South Street, Newark, Essex County, NJ

  16. 27. VIEW WEST, TYPICAL DOUBLE CONCRETE COLUMN AT EXPANSION JOINT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. VIEW WEST, TYPICAL DOUBLE CONCRETE COLUMN AT EXPANSION JOINT - Route 1 Extension, Southbound Viaduct, Spanning Conrail Yards, Wilson Avenue, Delancy Street, & South Street on Routes 1 & 9 Southbound, Newark, Essex County, NJ

  17. A parametric study of fine coal cleaning using column flotation

    SciTech Connect

    Parekh, B.K.; Groppo, J.G.; Bland, A.E.

    1986-01-01

    Recovery of fine coal is becoming an important and integral part of coal cleaning plants. Conventional froth flotation, which is commonly used in the coal industry, is inefficient at cleaning fine coal which contains large amounts of ultrafine ash or clays. The Kentucky Center for Energy Research Laboratory (KCERL) has been investigating an alternative method, counter-current column flotation, which is widely used in the mineral industry. Through an advanced cell design and counter-current wash of the froth, column flotation can produce a low-ash, clean coal product without sacrificing combustible recovery. An experimental program was conducted using a 2-inch internal diameter Canadian column flotation cell to examine the effect of various operating parameters on clean coal recovery and quality. The study investigated six operational parameters: feed rate, frother concentration, air flow rate, column height, pulp density and wash water rate.

  18. DETAIL OF THE FRONT PORCH SHOWING THE SQUARE COLUMN, COVED ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF THE FRONT PORCH SHOWING THE SQUARE COLUMN, COVED CEILING, AND STAINED CONCRETE FLOOR. VIEW FACING NORTHWEST. - Hickam Field, Officers' Housing Type H, 208 Sixth Street, Honolulu, Honolulu County, HI

  19. INTERIOR FOURTH FLOOR, SOUTH HALF, LOOKING SOUTH. NOTE MUSHROOM COLUMNS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    INTERIOR FOURTH FLOOR, SOUTH HALF, LOOKING SOUTH. NOTE MUSHROOM COLUMNS AND CEILING HAS WOODEN NAILERS. - Colt Fire Arms Company, North Armory, 36-150 Huyshope Avenue, 17-170 Van Dyke Avenue, 49 Vredendale Avenue, Hartford, Hartford County, CT

  20. View of first level from north showing interstitial structural columns ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of first level from north showing interstitial structural columns for the Shuttle assemble configuration. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL