[UPLC characteristic chromatographic profile of Poria].
Zhang, Qi; Wang, Zhenzhong; Xiao, Wei; Zhang, Liangqi; Bi, Kaishun; Jia, Ying
2012-04-01
To establish a UPLC characteristic chromatographic profile analysis method to quickly assess Poria quality and provide basis fro controlling Poria quality. The UPLC characteristic chromatographic profiles of fifteen batches of Poria were determined by ACQUITY UPLC, with HSS T3 Column (2.1 mm x 100 mm, 1.8 microm) eluted with the mobile phases of water containing 0.05% phosphoric acid and acetonitrile in gradient mode. The detection wavelength was set at 243 nm. The common mode of the UPLC characteristic chromatographic profile was set up. There were 20 common peaks, seven of which were identified, and the similar degrees of the fifteen samples to the common mode were between 0.787 and 0.974. The method was so time-saving that it can be used for the quality control of Poria.
Liu, Xuemei; Chen, Rui; Zeng, Guanghuai; Gao, Ying; Liu, Xiuping; Zhang, Donglei; Hu, Pei; Wang, Hongyun; Jiang, Ji
2018-06-04
Hemay005 is a novel small-molecule inhibitor of phosphodiesterase-4 developed for the treatment of psoriasis. Measurement of Hemay005 in biological samples is critical for evaluation of its pharmacokinetics in clinical studies. Methodology & results: Plasma and urine samples were extracted and then chromatographed on an Acquity UPLC HSS T3 column with a gradient elution. Detection was performed on a Xevo TQ-S tandem mass spectrometer using negative ESI. For the first time, a sensitive and robust ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was established and validated for the quantitative determination of Hemay005 in human plasma and urine, and it was successfully applied to evaluate the pharmacokinetics of Hemay005 in healthy subjects in a first-in-human study.
Simultaneous identification of synthetic and natural dyes in different food samples by UPLC-MS
NASA Astrophysics Data System (ADS)
Mandal, Badal Kumar; Mathiyalagan, Siva; Dalavai, Ramesh; Ling, Yong-Chien
2017-11-01
Fast foods and variety food items are populating among the food lovers. To improve the appearance of the food product in surviving gigantic competitive environment synthetic or natural food dyes are added to food items and beverages. Although regulatory bodies permit addition of natural colorants due to its safe and nontoxic nature in food, synthetic dyes are stringently controlled in all food products due to their toxicity by regulatory bodies. Artificial colors are need certification from the regulatory bodies for human consumption. To analyze food dyes in different food samples many analytical techniques are available like high pressure liquid chromatography (HPLC), thin layer chromatography (TLC), spectroscopic and gas chromatographic methods. However all these reported methods analyzed only synthetic dyes or natural dyes. Not a single method has analyzed both synthetic and natural dyes in a single run. In this study a robust ultra-performance liquid chromatographic method for simultaneous identification of 6 synthetic dyes (Tartrazine, Indigo carmine, Briliant blue, Fast green, malachite green, sunset yellow) and one natural dye (Na-Cu-Chlorophyllin) was developed using acquitic UPLC system equipped with Mass detector and acquity UPLC HSS T3 column (1.8 μm, 2.1 × 50 mm, 100Å). All the dyes were separated and their masses were determined through fragments’ masses analyses.
Saibaba, B; Vishnuvardhan, Ch; Johnsi Rani, P; Satheesh Kumar, N
2018-01-01
Almotriptan maleate (ALMT), a highly selective 5-hydroxy tryptamine 1B/1D (5-HT1B/1D) receptor agonist used in the treatment of migraine headache was subjected to various ICH (Q1A (R2)) specified guidelines. The drug underwent significant degradation under hydrolytic (acid, base and neutral), oxidative and photolytic stress conditions, while it was stable under thermal stress condition. A total of seven significant degradation products (DPs) were obtained. A simple, selective and reliable UPLC method has been developed for the separation of ALMT and its DPs using Acquity UPLC HSS Cyano (100 × 2.1 mm, 1.8 μm) column with mobile phase consisting of ammonium acetate (10 mM, pH 4.4) buffer and acetonitrile in gradient elution mode. Chromatographic analysis was performed at a flow rate of 0.3 mL/min using a PDA detector at a wavelength of 230 nm. All the DPs (DP-1 to DP-7) were characterized using UHPLC-ESI-QTOF based on mass fragmentation pattern and accurate m/z values. The developed UPLC method was validated in terms of specificity, linearity, precision and accuracy. The developed stability-indicating method helps in quantification of drug in the presence of DPs. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Stebounova, Larissa; Ebert, Scott M; Murry, Logan T; Adams, Christopher M; Murry, Daryl J
2018-04-26
Ultra-performance liquid chromatography (UPLC) interfaced with atmospheric pressure chemical ionization mass-spectrometry was used to separate and quantify ursolic acid (UA) and oleanolic acid (OA) in human plasma. UA and OA were extracted from 0.5 mL human plasma using supported liquid extraction and separated utilizing an Acquity UPLC HSS column. The method has been validated for both UA and OA quantitation with a limit of detection of 0.5 ng/mL. The UPLC separations are carried out with isocratic elution with methanol and 5 mM ammonium acetate in water (85:15) as a mobile phase at a flow rate of 0.4 mL/min. The assay was linear from 1 ng/mL to 100 ng/mL for both analytes. The total analysis time was 7 min with the retention times of 3.25 (internal standard), 3.65 (UA) and 3.85 min (OA). Recovery of drug from plasma ranged from 70% to 115%. Analysis of quality control samples at 3, 30 and 80 ng/mL (n = 14) had an intra-day coefficient of variation of 9.9%, 4.3% and 5.5%, respectively. A proof-of-concept study in human patients who consumed apple peels indicates that this analytical method could be applied to clinical studies of UA and/or OA in human subjects.
Wang, Ludi; Yang, Wei; Wu, Siyang; Wang, Shuyao; Kang, Chen; Ma, Xiaoli; Li, Yingfei; Li, Chuan
2018-05-01
Isochamaejasmin, neochamaejasmin A and daphnoretin derived from Stellera chamaejasme L. are important because of their reported anticancer properties. In this study, a sensitive UPLC-MS/MS method for the determination of isochamaejasmin, neochamaejasmin A and daphnoretin in rat plasma was developed. The analyte and IS were separated on an Acquity UPLC HSS T3 column (100 × 2.1 mm, 1.8 μm) using gradient elution with the mobile phase of aqueous solution (methanol-water, 1:99, v/v, containing 1 mm formic acid) and organic solution (methanol-water, 99:1, v/v, containing 1 mm formic acid) at a flow rate of 0.3 mL/min. Multiple reaction monitoring mode with negative electrospray ionization interface was carried out to detect the components. The method was validated in terms of specificity, linearity, accuracy, precision, stability, etc. Excellent linear behavior was observed over the certain concentration ranges with the correlation coefficient values >0.99. Intra- and inter-day precisions (RSD) were <6.7% and accuracy (RE) ranged from -7.0 to 12.0%. The validated method was successfully applied to investigate the pharmacokinetics of three chemical ingredients after oral administration of S. chamaejasme L. extract to rats. Copyright © 2017 John Wiley & Sons, Ltd.
Bidny, Sergei; Gago, Kim; Chung, Phuong; Albertyn, Desdemona; Pasin, Daniel
2017-04-01
An analytical method using ultra performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry (QTOF-MS) was developed and validated for the targeted toxicological screening and quantification of commonly used pharmaceuticals and drugs of abuse in postmortem blood using 100 µL sample. It screens for more than 185 drugs and metabolites and quantifies more than 90 drugs. The selected compounds include classes of pharmaceuticals and drugs of abuse such as: antidepressants, antipsychotics, analgesics (including narcotic analgesics), anti-inflammatory drugs, benzodiazepines, beta-blockers, amphetamines, new psychoactive substances (NPS), cocaine and metabolites. Compounds were extracted into acetonitrile using a salting-out assisted liquid-liquid extraction (SALLE) procedure. The extracts were analyzed using a Waters ACQUITY UPLC coupled with a XEVO QTOF mass spectrometer. Separation of the analytes was achieved by gradient elution using Waters ACQUITY HSS C18 column (2.1 mm x 150 mm, 1.8 μm). The mass spectrometer was operated in both positive and negative electrospray ionization modes. The high-resolution mass spectrometry (HRMS) data was acquired using a patented Waters MSE acquisition mode which collected low and high energy spectra alternatively during the same acquisition. Positive identification of target analytes was based on accurate mass measurements of the molecular ion, product ion, peak area ratio and retention times. Calibration curves were linear over the concentration range 0.05-2 mg/L for basic and neutral analytes and 0.1-6 mg/L for acidic analytes with the correlation coefficients (r2) > 0.96 for most analytes. The limits of detection (LOD) were between 0.001-0.05 mg/L for all analytes. Good recoveries were achieved ranging from 80% to 100% for most analytes using the SALLE method. The method was validated for sensitivity, selectivity, accuracy, precision, stability, carryover and matrix effects. The developed method was tested on a number of authentic forensic samples producing consistent results that correlated with results obtained from other validated methods. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Jacobs, Bart A W; Rosing, Hilde; de Vries, Niels; Meulendijks, Didier; Henricks, Linda M; Schellens, Jan H M; Beijnen, Jos H
2016-07-15
Quantification of the endogenous dihydropyrimidine dehydrogenase (DPD) substrate uracil (U) and the reaction product dihydrouracil (UH2) in plasma might be suitable for identification of patients at risk of fluoropyrimidine-induced toxicity as a result of DPD deficiency. In this paper, we describe the development and validation of a rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantification of U and UH2 in human plasma. Analytes were extracted by protein precipitation, chromatographically separated on an Acquity UPLC(®) HSS T3 column with gradient elution and analyzed with a tandem mass spectrometer equipped with an electrospray ionization source. U was quantified in the negative ion mode and UH2 in the positive ion mode. Stable isotopes for U and UH2 were used as internal standards. Total chromatographic run time was 5min. Validated concentration ranges for U and UH2 were from 1 to 100ng/mL and 10 to 1000ng/mL, respectively. Inter-assay bias and inter-assay precision for U were within ±2.8% and ≤12.4%. For UH2, inter-assay bias and inter-assay precision were within ±2.9% and ≤7.2%. Adequate stability of U and UH2 in dry extract, final extract, stock solution and plasma was demonstrated. Stability of U and UH2 in whole blood was only satisfactory when stored up to 4hours at 2-8°C, but not at ambient temperatures. An accurate, precise and sensitive UPLC-MS/MS assay for quantification of U and UH2 in plasma was developed. This assay is now applied to support clinical studies with fluoropyrimidine drugs. Copyright © 2016 Elsevier B.V. All rights reserved.
Flint, Robert B; Bahmany, Soma; van der Nagel, Bart C H; Koch, Birgit C P
2018-05-16
A simple and specific UPLC-MS/MS method was developed and validated for simultaneous quantification of fentanyl, sufentanil, cefazolin, doxapram and its active metabolite keto-doxapram. The internal standard was fentanyl-d5 for all analytes. Chromatographic separation was achieved with a reversed phase Acquity UPLC HSS T3 column with a run-time of only 5.0 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol with a total flow rate of 0.4 mL minute -1 . A plasma volume of only 50 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 5 analytes were linear. All analytes were stable for at least 48 hours in the autosampler. The method was validated according to US Food and Drug Administration guidelines. This method allows quantification of fentanyl, sufentanil, cefazolin, doxapram and keto-doxapram, which serves purposes for research, as well as therapeutic drug monitoring, if applicable. The strength of this method is the combination of a small sample volume, a short run-time, a deuterated internal standard, an easy sample preparation method and the ability to simultaneously quantify all analytes in one run. This article is protected by copyright. All rights reserved.
Huang, Mike-Qingtao; Kang, Lijuan; Wang, Weimin; Skee, Donna; Chen, Mu; Lin, Zhongping John; Verhaeghe, Tom; Weng, Naidong
2016-04-01
Previously, because of the difficulty of measuring very low levels (pg/mL) of norgestimate (NGM) due to rapid metabolism to its active and major metabolite, 17-Desacetyl norgestimate (DNGM), only DNGM and the co-administered ethinyl estradiol (EE2) were required to be analyzed in bioequivalence (BE) studies for oral contraceptive NGM/EE2 tablets. Recently, with more sensitive assays available, health authorities have requested that bioequivalence of NGM be also demonstrated in addition to DNGM and EE2. Therefore, it was important to establish a 3-in-1 method for the quantitation of EE2, NGM and DNGM in human plasma. Here a UPLC-MS/MS method for the simultaneous quantitation of EE2, NGM and DNGM in human plasma at low pg/mL range is described. EE2, NGM, DNGM and their isotopic labeled internal standards (IS) EE2-d4, NGM-d6 and DNGM-d6 in 0.4mL of human plasma were extracted with hexane/ethyl acetate. The extracts were evaporated to dryness and derivatized with dansyl chloride, to enhance the mass spec response. The derivatives were reconstituted with methanol and analyzed by UPLC-MS/MS. In order to minimize the ex-vivo conversion of NGM to DNGM, sodium fluoride/potassium oxalate was used as anti-coagulant. To achieve desirable throughput for sample analysis, UPLC-MS/MS with a run time of 4.4min was utilized. The calibration curve ranges were 5-500pg/mL for EE2 and NGM, and 25-2500pg/mL for DNGM, respectively. The chromatographic separation was achieved on a Waters Acquity UPLC HSS T3 (100×2.1mm, 1.8μm) column with a gradient elution. Assay accuracy, precision, linearity, selectivity, sensitivity and analyte stability covering sample storage and analysis were established. This validated UPLC-MS/MS method has been applied to a BE study for the determination of EE2, NGM and DNGM concentrations in human plasma. Copyright © 2016 Elsevier B.V. All rights reserved.
Sadler Simões, Susana; Castañera Ajenjo, Antonio; Dias, Mário João
2018-01-05
A method for the simultaneous determination of 11 illicit drugs, using the dried blood spot (DBS) sampling technique combined with the UPLC-MS/MS technology was developed to study its applicability within the forensic toxicology. The DBS samples, prepared from a blood volume of 50μL and using the Whatman® BFC 180 bloodstain cards, were extracted with a methanol/acetonitrile mixture. The chromatographic separation was performed using an Acquity UPLC ® HSS T3 column (100mm×2.1mm, 1.8μm) and an acetonitrile/2mM ammonium formate (0.1% formic acid) gradient. The detection was accomplished with a TQ Detector, operating in the ESI+ and MRM modes. The method was validated in terms of selectivity, matrix effect, extraction recovery (42%-91%), carryover, LOD and LOQ (0.5-1ng/mL and 1-5ng/mL, respectively), linearity (LOQ to 500ng/mL), intraday and interday precision (3.8-14% and 5.3-13%, respectively), accuracy (-9.3% to 7.9%) and dilution integrity. An eight months stability study at room temperature, 2-8°C and -10°C, was also performed, with the best results obtained at -10°C. The procedure was applied to 64 real samples (92 positive results for substances included in this study). The results were compared with the methodologies routinely applied in the laboratory and the statistical analysis allowed to establish an acceptable correlation. This study permitted to determine that the DBS can represent an alternative or a complement to conventional analytical and sampling techniques, responding to some of the present issues concerning the different forensic toxicology applications. Copyright © 2017 Elsevier B.V. All rights reserved.
De Baere, Siegrid; Croubels, Siska; Novak, Barbara; Bichl, Gerlinde; Antonissen, Gunther
2018-01-31
A sensitive and specific method for the quantitative determination of Fumonisin B1 (FB1), its partially hydrolysed metabolites pHFB1a+b and hydrolysed metabolite HFB1, and Fumonisin B2 (FB2) in broiler chicken plasma using ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS/MS) was developed. The sample preparation was rapid, straightforward and consisted of a deproteinization and phospholipid removal step using an Oasis ® Ostro TM 96-well plate. Chromatography was performed on an Acquity HSS-T3 column, using 0.3% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. The MS/MS instrument was operated in the positive electrospray ionization mode and the two multiple reaction monitoring transitions were monitored for each component for quantification and identification, respectively. The method was validated in-house: matrix-matched calibration graphs were prepared and good linearity (r ≥ 0.99) was achieved over the concentration ranges tested (1-500 ng/mL for FB1 and FB2; 0.86-860 ng/mL for pHFB1a; 0.72-1430 ng/mL for pHFB1b and 2.5-2500 ng/mL for HFB1). Limits of quantification (LOQ) and detection (LOD) in plasma ranged between 0.72 to 2.5 ng/mL and 0.03 to 0.17 ng/mL, respectively. The results for the within-day and between-day precision and accuracy fell within the specified ranges. Moreover, the method was transferred to an UPLC high-resolution mass spectrometry (HR-MS) instrument in order to determine potential metabolites of HFB1, such as N-acyl-HFB1s and phase II metabolites. The method has been successfully applied to investigate the toxicokinetics and biotransformation of HFB1 in broiler chickens.
De Baere, Siegrid; Novak, Barbara; Bichl, Gerlinde
2018-01-01
A sensitive and specific method for the quantitative determination of Fumonisin B1 (FB1), its partially hydrolysed metabolites pHFB1a+b and hydrolysed metabolite HFB1, and Fumonisin B2 (FB2) in broiler chicken plasma using ultra-performance liquid chromatography combined with tandem mass spectrometry (UPLC-MS/MS) was developed. The sample preparation was rapid, straightforward and consisted of a deproteinization and phospholipid removal step using an Oasis® OstroTM 96-well plate. Chromatography was performed on an Acquity HSS-T3 column, using 0.3% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. The MS/MS instrument was operated in the positive electrospray ionization mode and the two multiple reaction monitoring transitions were monitored for each component for quantification and identification, respectively. The method was validated in-house: matrix-matched calibration graphs were prepared and good linearity (r ≥ 0.99) was achieved over the concentration ranges tested (1–500 ng/mL for FB1 and FB2; 0.86–860 ng/mL for pHFB1a; 0.72–1430 ng/mL for pHFB1b and 2.5–2500 ng/mL for HFB1). Limits of quantification (LOQ) and detection (LOD) in plasma ranged between 0.72 to 2.5 ng/mL and 0.03 to 0.17 ng/mL, respectively. The results for the within-day and between-day precision and accuracy fell within the specified ranges. Moreover, the method was transferred to an UPLC high-resolution mass spectrometry (HR-MS) instrument in order to determine potential metabolites of HFB1, such as N-acyl-HFB1s and phase II metabolites. The method has been successfully applied to investigate the toxicokinetics and biotransformation of HFB1 in broiler chickens. PMID:29385109
Dinç, Erdal; Büker, Eda
2012-01-01
A new application of continuous wavelet transform (CWT) to overlapping peaks in a chromatogram was developed for the quantitative analysis of amiloride hydrochloride (AML) and hydrochlorothiazide (HCT) in tablets. Chromatographic analysis was done by using an ACQUITY ultra-performance LC (UPLC) BEH C18 column (50 x 2.1 mm id, 1.7 pm particle size) and a mobile phase consisting of methanol-0.1 M acetic acid (21 + 79, v/v) at a constant flow rate of 0.3 mL/min with diode array detection at 274 nm. The overlapping chromatographic peaks of the calibration set consisting of AML and HCT mixtures were recorded rapidly by using an ACQUITY UPLC H-Class system. The overlapping UPLC data vectors of AML and HCT drugs and their samples were processed by CWT signal processing methods. The calibration graphs for AML and HCT were computed from the relationship between concentration and areas of chromatographic CWT peaks. The applicability and validity of the improved UPLC-CWT approaches were confirmed by recovery studies and the standard addition technique. The proposed UPLC-CWT methods were applied to the determination of AML and HCT in tablets. The experimental results indicated that the suggested UPLC-CWT signal processing provides accurate and precise results for industrial QC and quantitative evaluation of AML-HCT tablets.
Juenke, JoEtta M; Brown, Paul I; Urry, Francis M; Johnson-Davis, Kamisha L; McMillin, Gwendolyn A
2013-08-23
Most antipsychotic drugs that are commonly prescribed in the USA are monitored by liquid and gas chromatographic methods. Method performance has been improved using ultra high pressure liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). A rapid and simple procedure for monitoring haloperidol, thiothixene, fluphenazine, and perphenazine is described here. Antipsychotic drug concentrations in serum and plasma were determined by LCMS/MS (Waters Acquity UPLC TQD). The instrument is operated with an ESI interface, in multiple reaction monitoring (MRM), and positive ion mode. The resolution of both quadrupoles was maintained at unit mass with a peak width at half height of 0.7amu. Data analysis was performed using the Waters Quanlynx software. Serum or plasma samples were thawed at room temperature and a 100μL aliquot was placed in a tube. Then 300μL of precipitating reagent (acetonitrile-methanol [50:50, volume: volume]) containing the internal standard (0.12ng/μL Imipramine-D3) was added to each tube. The samples were vortexed and centrifuged. The supernatant was transferred to an autosampler vial and 8μL was injected into the UPLC-MS/MS. Utilizing a Waters Acquity UPLC HSS T3 1.8μm, 2.1×50mm column at 25ºC, the analytes were separated using a timed, linear gradient of acetonitrile and water, each having 0.1% formic acid added. The column is eluted into the LC-MS/MS to detect imipramine D3 at transition 284.25>89.10, haloperidol at 376.18>165.06, thiothixene at 444.27>139.24, fluphenazine at 438.27>171.11, and perphenazine at 404.19>143.07. Secondary transitions for each analyte are also monitored for imipramine D3 at 284.25>193.10, haloperidol at 376.18>122.97, thiothixene at 444.27>97.93, fluphenazine at 438.27>143.08, and perphenazine at 404.19>171.11. The run-time is 1.8min per injection with baseline resolved chromatographic separation. The analytical measurement range was 0.2 to 12.0ng/mL for fluphenazine and perphenazine, and was 1 to 60.0ng/mL for haloperidol and thiothixene. Intra-assay and inter-assay imprecisions (CV) were less than 15% at two concentrations for each analyte. By utilizing a LC-MS/MS method we combined two previously established analytical assays into one, yielding a 75% time-savings on set-up, and a significantly shortened analytical run-time. These changes reduced the turn-around time for analysis and eliminated interference issues resulting in fewer injections and increased column lifetime. Copyright © 2013 Elsevier B.V. All rights reserved.
Zong, Shi-Yu; Han, Han; Wang, Bing; Li, Ning; Dong, Tina Ting-Xia; Zhang, Tong; Tsim, Karl W K
2015-12-04
A reliable ultra-high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UHPLC-ESI-MS/MS) method for the fast simultaneous determination of 13 nucleosides and nucleobases in Cordyceps sinensis (C. sinensis) with 2-chloroadenosine as internal standard was developed and validated. Samples were ultrasonically extracted in an ice bath thrice, and the optimum analyte separation was performed on an ACQUITY UPLC(TM) HSS C18 column (100 mm × 2.1 mm, 1.8 μm) with gradient elution. All targeted analytes were separated in 5.5 min. Furthermore, all calibration curves showed good linear regression (r > 0.9970) within the test ranges, and the limits of quantitation and detection of the 13 analytes were less than 150 and 75 ng/mL, respectively. The relative standard deviations (RSDs) of intra- and inter-day precisions were <6.23%. Recoveries of the quantified analytes ranged within 85.3%-117.3%, with RSD < 6.18%. The developed UHPLC-ESI-MS/MS method was successfully applied to determine nucleosides and nucleobases in 11 batches of C. sinensis samples from different regions in China. The range for the total content in the analyzed samples was 1329-2057 µg/g.
He, Jie; Gao, Song; Hu, Ming; Chow, Diana S.-L.; Tam, Vincent H.
2013-01-01
Objectives A rapid, sensitive and robust ultra-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of four major polymyxin B components (polymyxin B1, polymyxin B2, polymyxin B3 and isoleucine-polymyxin B1) in serum and epithelial lining fluid (ELF) samples. Methods A Waters Acquity UPLC HSS C18 column was used with 0.1% formic acid in water/acetonitrile as mobile phases. Analysis was performed in a positive ionization mode with multiple-reactions monitoring scan type. Five percent trichloroacetic acid was used to precipitate proteins in biological samples and to increase the sensitivity of detection. Results Our results showed a linear concentration range of 0.0065–3.2 mg/L for all the major polymyxin B components in both serum and ELF, respectively; the interday variation was <10% and the accuracy was 88%–115%. The validated method was used to characterize the pharmacokinetics (serum and ELF) of polymyxin B in mice. Conclusions This is the first report, to date, examining the individual pharmacokinetics of various polymyxin B components in mice. Our results revealed no considerable differences in clearances among the components. The limited exposure of polymyxin B in ELF observed was consistent with the less favourable efficacy of polymyxin B reported for the treatment of pulmonary infections. This method can be used to further examine the pharmacokinetics of polymyxin B in a variety of clinical and experimental settings. PMID:23341128
Davanço, Marcelo Gomes; de Campos, Michel Leandro; Peccinini, Rosângela Gonçalves
2015-07-01
Benznidazole (BNZ) and nifurtimox are the only drugs available for treating Chagas disease. In this work, we validated a bioanalytical method for the quantification of BNZ in plasma aimed at improving sensitivity and time of analysis compared with the assays already published. Furthermore, we demonstrated the application of the method in a preclinical pharmacokinetic study after administration of a single oral dose of BNZ in Wistar rats. A Waters® Acquity UHPLC system equipped with a UV-vis detector was employed. The method was established using an Acquity® UHPLC HSS SB C18 protected by an Acquity® UHPLC HSS SB C18 VanGuard guard column and detection at 324 nm. The mobile phase consisted of ultrapure water-acetonitrile (65:35), and elution was isocratic. The mobile phase flow rate was 0.55 mL/min, the volume of injection was 1 μL, and the run time was just 2 min. The samples were kept at 25°C until injection and the column at 45°C for the chromatographic separation. The sample preparation was performed by a rapid protein precipitation with acetonitrile. The linear concentration range was 0.15-20 µg/mL. The pharmacokinetic parameters of BNZ in rats were determined and the method was considered sensitive, fast and suitable for application in pharmacokinetic studies. Copyright © 2014 John Wiley & Sons, Ltd.
Zhou, Jie; Yi, Huan; Zhao, Zhong-Xiang; Shang, Xue-Ying; Zhu, Ming-Juan; Kuang, Guo-Jun; Zhu, Chen-Chen; Zhang, Lei
2018-06-05
In this study, a systematic method was established for the holistic quality control of Ilex kudingcha C. J. Tseng, a popular functional drink for adjuvant treatment of diabetes, hypertension, obesity and hyperlipidemia. Both qualitative and quantitative analyses were conducted. For qualitative analysis, an ultra high performance liquid chromatography (UHPLC) coupled with an electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-qTOF-MS) method was established for rapid separation and structural identification of the constituents in Ilex kudingcha. Samples were separated on an ACQUITY UPLC HSS T3C 18 column (2.1 mm × 100 mm, 1.8 μm) by gradient elution using 0.1% (v/v) formic acid (solvent A) and acetonitrile (solvent B) as mobile phases at a flow rate of 0.25 mL min -1 . The chromatographic profiling of Ilex kudingcha by UHPLC-qTOF-MS/MS resulted in the characterization of 53 compounds, comprising 18 compounds that were unambiguously identified by comparison with reference standards. For quantitative analysis, 18 major compounds from 15 batches of Ilex kudingcha samples were simultaneously detected by UPLC-DAD at wavelengths of 210 nm, 260 nm, and 326 nm. The method was validated with respect to precision, linearity, repeatability, stability, accuracy, and so on. The contents of the 18 target compounds were applied for hierarchical clustering analysis (HCA) and principal component analysis (PCA) to differentiate between the samples. The results of HCA and PCA were consistent with each other. Sample No. 1 differed significantly based on HCA and PCA, and the differentiating components were confirmed to originate from different batches of samples. Phenolic acids and triterpenes were found to be the main ingredients in Ilex kudingcha. This strategy was effective and straightforward, and provided a potential approach for holistic quality control of Ilex kudingcha. Copyright © 2018. Published by Elsevier B.V.
Liu, Xuemei; Hu, Pei; Wang, Yongsheng; Wang, Xizhu; Huang, Jinghua; Li, Jin; Li, Cheng; Wang, Hongyun; Jiang, Ji
2018-04-10
Monocyte locomotion inhibitory factor (MLIF, Met-Gln-Cys-Asn-Ser), a pentapeptide with anti-inflammatory activity, was developed for neural protection in acute ischemic stroke. Determination of MLIF in human plasma samples is of great importance for pharmacokinetic evaluation in clinical studies. A reliable and sensitive method based on ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was established for the measurement of MLIF in human plasma. Instability of peptide in matrix was the primary challenge in method development, which was properly resolved by addition of acidification reagents like sulfuric acid. Samples were prepared by protein precipitation and then analyzed using a gradient chromatographic separation over an ACQUITY UPLC HSS T 3 column. The mobile phase consisted of acetonitrile containing 0.2% formic acid and water containing 0.2% formic acid and gradient elution was performed at a flow rate of 0.4 mL/min. Detection was carried out on a Xevo TQ-S tandem mass spectrometer and positive electrospray ionization was employed in the multiple reaction monitoring (MRM) mode. This method was fully validated over the concentration range of 0.5-40 ng/mL with a lower limit of quantification (LLOQ) of 0.5 ng/mL. The inter- and intra-batch precision was no more than 8.8% and the accuracy was between 88.7 and 104.2%. The mean extraction recovery was 43.3% and the detection was independent of matrix. Besides, the analyte proved to be stable under various handling processes and storage conditions after acidification. Finally, the method was applied to the first-in-human (FIH) study of MLIF in Chinese healthy subjects. Copyright © 2018. Published by Elsevier B.V.
Azougagh, M; Elkarbane, M; Bakhous, K; Issmaili, S; Skalli, A; Iben Moussad, S; Benaji, B
2016-09-01
An innovative simple, fast, precise and accurate ultra-high performance liquid chromatography (UPLC) method was developed for the determination of diclofenac (Dic) along with its impurities including the new dimer impurity in various pharmaceutical dosage forms. An Acquity HSS T3 (C18, 100×2.1mm, 1.8μm) column in gradient mode was used with mobile phase comprising of phosphoric acid, which has a pH value of 2.3 and methanol. The flow rate and the injection volume were set at 0.35ml·min(-1) and 1μl, respectively, and the UV detection was carried out at 254nm by using photodiode array detector. Dic was subjected to stress conditions from acid, base, hydrolytic, thermal, oxidative and photolytic degradation. The new developed method was successfully validated in accordance to the International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection, limit of quantitation, precision, linearity, accuracy and robustness. The degradation products were well resolved from main peak and its seven impurities, proving the specificity power of the method. The method showed good linearity with consistent recoveries for Dic content and its impurities. The relative percentage of standard deviation obtained for the repeatability and intermediate precision experiments was less than 3% and LOQ was less than 0.5μg·ml(-1) for all compounds. The new proposed method was found to be accurate, precise, specific, linear and robust. In addition, the method was successfully applied for the assay determination of Dic and its impurities in the several pharmaceutical dosage forms. Copyright © 2016 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.
Kumar, Navneet; Sangeetha, D.; Balakrishna, P.
2011-01-01
Background: In pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive, and specific reverse phase ultra-performance liquid chromatographic (UPLC) method was developed for the quantitative determination of duloxetine in cleaning validation swab samples. Material and Methods: The method was validated using an Acquity UPLC™ HSS T3 (100 × 2.1 mm2) 1.8 μm column with a isocratic mobile phase containing a mixture of 0.01 M potassium dihydrogen orthophosphate, pH adjusted to 3.0 with orthophosphoric acid and acetonitrile (60:40 v/v). The flow rate of the mobile phase was 0.4 ml/min with a column temperature of 40°C and detection wavelength at 230 nm. Cotton swabs, moisten with extraction solution (90% methanol and 10% water), were used to remove any residue of drug from stainless steel, glass and silica surfaces, and give recoveries >80% at four concentration levels. Results: The precision of the results, reported as the relative standard deviation, were below 1.5%. The calibration curve was linear over a concentration range from 0.02 to 5.0 μg/ml with a correlation coefficient of 0.999. The detection limit and quantitation limit were 0.006 and 0.02 μg/ml, respectively. The method was validated over a concentration range of 0.05–5.0 μg/ml. Conclusion: The developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781449
Gong, Xiaobin; Yang, Le; Zhang, Feng; Liang, Youtian; Gao, Shouhong; Liu, Ke; Chen, Wansheng
2017-11-01
A fully valid UHPLC-MS/MS method was developed for the determination of etoposide, gemcitabine, vinorelbine and their metabolites (etoposide catechol, 2',2'-difluorodeoxyuridine and 4-O-deacetylvinorelbine) in human plasma. The multiple reaction monitoring mode was performed with an electrospray ionization interface operating in both the positive and negative ion modes per compound. The method required only 100 μL plasma with a one-step simple de-proteinization procedure, and a short run time of 7.5 min per sample. A Waters ACQUITY UPLC HSS T3 column (2.1 × 100 mm, 1.8 μm) provided chromatographic separation of analytes using a binary mobile phase gradient (A, 0.1% formic acid in acetonitrile, v/v; B, 0.1% formic acid in water, v/v). Linear coefficients of correlation were >0.995 for all analytes. The relative deviation of this method was <10% for intra- and inter-day assays and the accuracy ranged between 86.35% and 113.44%. The mean extraction recovery and matrix effect of all the analytes were 62.07-105.46% and 93.67-105.87%, respectively. This method was successfully applied to clinical samples from patients with lung cancer. Copyright © 2017 John Wiley & Sons, Ltd.
Siva Selva Kumar, M; Ramanathan, M
2016-02-01
A simple and sensitive ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of olanzapine (OLZ), risperidone (RIS) and 9-hydroxyrisperidone (9-OHRIS) in human plasma in vitro. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP18 column maintained at 40°C. Quantification was performed on a photodiode array detector set at 277 nm and clozapine was used as internal standard (IS). OLZ, RIS, 9-OHRIS and IS retention times were found to be 0.9, 1.4, .1.8 and 3.1 min, respectively, and the total run time was 4 min. The method was validated for selectivity, specificity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 1-100 ng/mL for OLZ, RIS and 9-OHRIS. Intra- and inter-day precisions for OLZ, RIS and 9-OHRIS were found to be good with the coefficient of variation <6.96%, and the accuracy ranging from 97.55 to 105.41%, in human plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of RIS and 9-OHRIS in human plasma. Copyright © 2015 John Wiley & Sons, Ltd.
Ramanujam, N; Sivaselvakumar, M; Ramalingam, S
2017-11-01
A simple, sensitive and reproducible ultra-performance liquid chromatography (UPLC) method has been developed and validated for simultaneous estimation of polychlorinated biphenyl (PCB) 77 and PCB 180 in mouse plasma. The sample preparation was performed by simple liquid-liquid extraction technique. The analytes were chromatographed on a Waters Acquity H class UPLC system using isocratic mobile phase conditions at a flow rate of 0.3 mL/min and Acquity UPLC BEH shield RP 18 column maintained at 35°C. Quantification was performed on a photodiode array detector set at 215 nm and PCB 101 was used as internal standard (IS). PCB 77, PCB 180, and IS retention times were 2.6, 4.7 and 2.8 min, respectively, and the total run time was 6 min. The method was validated for specificity, selectivity, recovery, linearity, accuracy, precision and sample stability. The calibration curve was linear over the concentration range 10-3000 ng/mL for PCB 77 and PCB 180. Intra- and inter-day precisions for PCBs 77 and 180 were found to be good with CV <4.64%, and the accuracy ranged from 98.90 to 102.33% in mouse plasma. The validated UPLC method was successfully applied to the pharmacokinetic study of PCBs 77 and 180 in mouse plasma. Copyright © 2017 John Wiley & Sons, Ltd.
Hussain, Afzal; AlAjmi, Mohamed F; Ali, Imran
2018-06-01
The pentafluorophenyl (PFP) column is emerging as a new advancement in separation science to analyze a wide range of analytes and, thus, its separation mechanism at supramolecular level is significant. We developed a mechanism for the separation of ibuprofen and omeprazole using different combinations (ranging from 50:50 to 60:40) of water-acetonitrile containing 0.1% formic acid as the mobile phase. The column used was Waters Acquity UPLC HSS PFP (75 × 2.1 mm, 1.8 μm). The reverse order of elution was observed in different combinations of the mobile phases. The docking study indicated hydrogen bonding between ibuprofen and PFP stationary phase (binding energy was -11.30 kJ/mol). Separation at PFP stationary phase is controlled by hydrogen bonding along with π-π interactions. This stationary phase may be used to analyze both aromatic and aliphatic analytes. The developed mechanism will be useful to separate various analytes by considering the possible interactions, leading to saving of energy, time and money. In addition, this work will be highly useful in preparative chromatography where separation is the major problem at a large scale. Moreover, the developed LC-MS-QTOF method may be used to analyze ibuprofen and omeprazole in an unknown sample owing to the low value of detection limits. Copyright © 2018 John Wiley & Sons, Ltd.
Liang, Xiao; Tian, Jinlong; Li, Lingzhi; Gao, Jun; Zhang, Qingyi; Gao, Pinyi; Song, Shaojiang
2014-03-01
A rapid and reliable microwave extraction and the triple quadrupole-linear ion trap mass spectrometry method was developed and validated for the determination of eight alkaloids in Portulaca oleracea L. The optimal microwave extraction (MWE) condition was performed at 60 °C for 12 min with ethanol-water (70:30, v/v) as the extracting solvent, and the solvent to solid ratio was 30:1. The alkaloids were first detected simultaneously by electrospray ionization tandem mass spectrometry under positive-negative conversion multiple reaction monitor ((+/-)MRM) technique. With investigating three different columns, samples were separated in only 8 min on a Waters ACQUITY UPLC HSS T3 (50 × 2.1 mm(2), 1.8 μm) column using acetonitrile and formic acid-water solution as a mobile phase with a flow rate at 0.2 mL/min. All calibration curves showed good linearity (r>0.999) within the test ranges. The method developed was validated with acceptable sensitivity, intra- and inter-day precision, reproducibility, and extraction recoveries. It was successfully applied to the determination of eight alkaloids in Portulaca oleracea L. from different sources and different harvest periods. The method also provide a reference for extraction and determination of alkaloids in other complex systems. © 2013 Elsevier B.V. All rights reserved.
Lou, Qiong; Ye, Xiaolan; Zhou, Yingyi; Li, Hua; Song, Fenyun
2015-06-01
A method incorporating double-wavelength ultra high performance liquid chromatography with quadrupole time-of-flight mass spectrometry was developed for the investigation of the chemical fingerprint of Ganmaoling granule. The chromatographic separations were performed on an ACQUITY UPLC HSS C18 column (2.1 × 50 mm, 1.8 μm) at 30°C using gradient elution with water/formic acid (1%) and acetonitrile at a flow rate of 0.4 mL/min. A total of 11 chemical constituents of Ganmaoling granule were identified from their molecular weight, UV spectra, tandem mass spectrometry data, and retention behavior by comparing the results with those of the reference standards or literature. And 25 peaks were selected as the common peaks for fingerprint analysis to evaluate the similarities among 25 batches of Ganmaoling granule. The results of principal component analysis and orthogonal projection to latent structures discriminant analysis showed that the important chemical markers that could distinguish the different batches were revealed as 4,5-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4-O-caffeoylquinic acid. This is the first report of the ultra high performance liquid chromatography chemical fingerprint and component identification of Ganmaoling granule, which could lay a foundation for further studies of Ganmaoling granule. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Rui, Wen; Chen, Hongyuan; Tan, Yuzhi; Zhong, Yanmei; Feng, Yifan
2010-05-01
A rapid method for the analysis of the main components of the total glycosides of Ranunculus japonicus (TGOR) was developed using ultra-performance liquid chromatography with quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS). The separation analysis was performed on a Waters Acquity UPLC system and the accurate mass of molecules and their fragment ions were determined by Q-TOF MS. Twenty compounds, including lactone glycosides, flavonoid glycosides and flavonoid aglycones, were identified and tentatively deduced on the basis of their elemental compositions, MS/MS data and relevant literature. The results demonstrated that lactone glycosides and flavonoids were the main constituents of TGOR. Furthermore, an effective and rapid pattern was established allowing for the comprehensive and systematic characterization of the complex samples.
Shibata, Mai; Hashi, Sachiyo; Nakanishi, Haruka; Masuda, Satohiro; Katsura, Toshiya; Yano, Ikuko
2012-12-01
The purpose of this study was to develop an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine-10,11-epoxide, clobazam, N-desmethylclobazam, clonazepam, diazepam, N-desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N-desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C₁₈ column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r² < 0.99). The precision and accuracy values for intra- and inter-assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC-MS/MS were lower than those detected by the immunoassays, which might be caused by the cross-reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC-MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.
van der Ham, M; Albersen, M; de Koning, T J; Visser, G; Middendorp, A; Bosma, M; Verhoeven-Duif, N M; de Sain-van der Velden, M G M
2012-01-27
Since vitamin B6 is essential for normal functioning of the central nervous system, there is growing need for sensitive analysis of B6 vitamers in cerebrospinal fluid (CSF). This manuscript describes the development and validation of a rapid, sensitive and accurate method for quantification of the vitamin B6 vitamers pyridoxal (PL), pyridoxamine (PM), pyridoxine (PN), pyridoxic acid (PA), pyridoxal 5'-phosphate (PLP), pyridoxamine 5'-phosphate (PMP) and pyridoxine 5'-phosphate (PNP) in human CSF. The method is based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with a simple sample preparation procedure of protein precipitation using 50 g L(-1) trichloroacetic acid containing stable isotope labeled internal standards: PL-D(3) for PL and PM, PN-(13)C(4) for PN, PA-D(2) for PA and PLP-D(3) for the phosphorylated vitamers. B6 vitamers were separated (Acquity HSS-T3 UPLC column) with a buffer containing acetic acid, heptafluorobutyric acid and acetonitrile. Positive electrospray ionization was used to monitor transitions m/z 168.1→150.1 (PL), 169.1→134.1 (PM), 170.1→134.1 (PN), 184.1→148.1 (PA), 248.1→150.1 (PLP), 249.1→232.1 (PMP) and 250.1→134.1 (PNP). The method was validated at three concentration levels for each B6 vitamer in CSF. Recoveries of the internal standards were between 93% and 96%. Intra- and inter-assay variations were below 20%. Accuracy tests showed deviations from 3% (PN) to 39% (PMP). Limits of quantification were in the range of 0.03-5.37 nM. Poor results were obtained for quantification of PNP. The method was applied to CSF samples of 20 subjects and two patients on pyridoxine supplementation. Using minimal CSF volumes this method is suitable for implementation in a routine diagnostic setting. Copyright © 2011 Elsevier B.V. All rights reserved.
Ezzeldin, Essam; Mostafa, Gamal Ae; Iqbal, Muzaffar; Al-Rashood, Khalid A; Asiri, Yousef; El-Nahhas, Toqa
2018-05-10
Mozavaptan is a nonpeptide vasopressin receptor antagonist approved for the treatment of ectopic antidiuretic hormone secretion syndrome. A simple, rapid and fully validated UPLC/MS-MS method was developed for the quantitation of mozavaptan in rat plasma. The chromatographic separation was conducted on an Acquity UPLC BEH™ C 18 column with an optimum mobile phase of 10 mM ammonium acetate buffer and 0.1% formic acid in acetonitrile (30:70 v/v) at a flow rate of 0.3 ml/min. The multiple reaction monitoring transitions were performed at m/z 428.16→119.03 for mozavaptan and m/z 237.06→179.10 for carbamazepine (internal standard). The method was effectively applied for the determination of mozavaptan pharmacokinetic parameters after the oral administration of 3 mg/kg mozavaptan in rats.
Duan, Shengnan; Qi, Wen; Zhang, Siwen; Huang, Kunkun; Yuan, Dan
2017-10-01
An ultra high performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight mass spectrometry method in both positive and negative ion modes was established in order to comprehensively investigate the major constituents in Wu Ji Bai Feng Pill. Briefly, a Waters ACQUITY UPLC HSS C 18 column was used to separate the aqueous extract of Wu Ji Bai Feng Pill. A total of 0.1% formic acid in acetonitrile and 0.1% aqueous formic acid v/v were used as the mobile phase. All analytes were determined using quadrupole time-of-flight mass spectrometry with electrospray ionization source in positive and negative ion modes. At length, a total of 173 components including flavones and their glycosides, monoterpene glycosides, triterpene saponins, phenethylalchohol glycosides, iridoid glycosides, phthalides, tanshinones, phenolic acids, sesquiterpenoids and cyclopeptides were identified or tentatively characterized in Wu Ji Bai Feng Pill in an analysis of 16.0 min based on the accurate mass and tandem mass spectrometry behaviors. The developed method is rapid and highly sensitive to characterize the chemical constituents of Wu Ji Bai Feng Pill, which could not only be used for chemical standardization and quality control of Wu Ji Bai Feng Pill, but also be helpful for further study in vivo metabolism of Wu Ji Bai Feng Pill. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sun, Zhi; Kong, Xiangzhen; Zuo, Lihua; Kang, Jian; Hou, Lei; Zhang, Xiaojian
2016-02-01
A novel and rapid microwave extraction and ultra high performance liquid chromatography with tandem mass spectrometry method was developed and validated for the simultaneous determination of 25 bioactive constituents (including two new constituents) in Fructus Alpinia oxyphylla. The optimized conditions of the microwave extraction was a microwave power of 300 W, extraction temperature of 80°C, solvent-to-solid ratio of 30 mL/g and extraction time of 8 min. Separation was achieved on a Waters ACQUITY UPLC(®) HSS C18 column (2.1 mm× 50 mm, 1.8 μm) using gradient elution with a mobile phase consisting of acetonitrile and 1 mM ammonium acetate at a flow rate of 0.2 mL/min. This is the first report of the simultaneous determination of 25 bioactive constituents in Fructus Alpinia oxyphylla by ultra high performance liquid chromatography with tandem mass spectrometry. The method was validated with good linearity, acceptable precision and accuracy. The validated method was successfully applied to determine the contents of 25 bioactive constituents in Fructus Alpinia oxyphylla from different sources and the analysis results were classified by hierarchical cluster analysis, which indicated the effect of different cultivation regions on the contents of constituents. This study provides powerful and practical guidance in the quality control of Alpinia oxyphylla and lays the foundation for further research of Alpinia oxyphylla. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Pin; Zhang, Jing; Shi, Ying; Shao, Bing
2015-03-01
An analytical method was developed to simultaneously detect triclosan (TCS) and triclocarban (TCC) in human breast milk using solid-phase extraction (SPE) with ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). Samples were extracted by acetonitrile and purified with C -18 SPE cartridge after enzymolysis with β-glucuronidase/arylsulfatase. The chromatographic separation was performed on a Waters ACQUITY UPLC™ HSS T3 column (100 mm x 2. 1 mm, 1. 8 µm) with gradient elution using methanol and water at a flow rate of 0. 3 ml/min. The target analytes were assayed by triple quadrupole mass spectrometer operating in the negative ion mode. Quantification was performed by isotopic internal standard calibration. Satisfactory linearity (r2 > 0. 999) was obtained over the range of 0. 2 - 20. 0 µg/L and 0. 02 - 2. 0 µg/L for triclosan and triclocarban, respectively, with the limits of quantifications (LOQs) of 0. 41 and 0. 03 µg/kg. Average recoveries of two target compounds (spiked at three concentration levels) ranged from 100. 2% to 119. 3%, with the relative standard deviations (RSDs) between 5. 91% and 11. 31% (n =6). Twenty-five real samples (n = 25) were detected containing TCS and TCC at concentrations of < LOQ - 0. 77 µg/kg and < LOQ - 4. 28 µg/kg, respectively. Due to its high sensitivity and good reproductivity, this method can be applied to analyze TCS and TCC in human breast milk.
Li, Kun-Yan; Zhou, Yan-Gang; Ren, Hua-Yi; Wang, Feng; Zhang, Bi-Kui; Li, Huan-De
2007-05-01
The ultra-performance liquid chromatography-electrospray tandem mass spectrometry (UPLC-ESI-MS/MS) method has been developed to perform the determination of quetiapine, perospirone, aripiprazole and quetiapine sulfoxide in in vitro samples in less than 3 min. The UPLC separation was carried out using an Acquity UPLC BEH C18 column (100 mm x 2.1mm i.d., 1.7 microm particle size) that provided high efficiency and resolution in combination with high linear velocities. The UPLC system was coupled to a Waters Micromass Quattro Premier XE tandem quadrupole mass spectrometer. This system permits high-speed data acquisition without peak intensity degradation, and produces sharp and narrow chromatographic peaks (w(h) about 2.5s) of compounds. The determination was performed in multiple reaction monitoring (MRM) mode. The quantification parameters of the developed method were established, obtaining instrumental LODs lower than 0.005 microg/l and a repeatability at a low concentration level lower than 10% CV (n=10). Finally, the method was successfully applied to the analysis of atypical antipsychotics and some metabolites in in vitro samples.
Nie, Hui; Yan, Hui; Qian, Da-Wei; Duan, Jin-Ao; Ou, Yang-Zhen; Qian, Ye-Fei; Guan, Han-Liang
2013-07-01
To establish the UPLC specific chromatogram of Lily and analyze the specific peaks compositions by ESI-QTOF-MS. The samples were conducted by ACQUITY UPLC BEH C18 Column (2.1 mm x 100 mm, 1.7 microm) and eluted with acetonitrile and 0.1% formic acid at the flow rate of 0.4 mL/min. The detection wavelength was set at 320 nm and column temperature was 35 degrees C. Negative ion mode was chosen for qualitative analysis. The capillary voltage was set at 3.0 kV. The nebulization gas was set to 600 L/h at 350 degrees C, and the source temperature was 120 degrees C. The specific chromatogram of Lily was obtained. There were 19 common peaks. Twelve phenylpropenoid glycerides compositions were identified. Among them, 6 compositions were identified by comparison with the reference substances and others were identified by MS and MS2 data. UPLC specific chromatogram can be used for the quality evaluation of Lily, giving support to quality control comprehensively.
Tang, Ce; Wen, Jian; Wang, Jing; Zhao, Ke-Hui; Fan, Gang; Meng, Xian-Li; Zou, Zhong-Mei; Zhang, Yi
2017-04-01
This study is to develop an UPLC-PDA method for determination of 10 major components in Pterocephalus. The UPLC-PDA assay was performed on a Waters Acquity UPLCR BEH C₁₈(2.1 mm ×100 mm,1.7 μm), and the column temperature was at 30 ℃. The mobile phase consists of water containing 0.2% phosphoric acid (A) and acetonitrile (B) in gradient elution at a flow rate of 0.4 mL•min⁻¹. The detection wave length was set at 237 and 325 nm, and the injection volume was 1 μL in the UPLC system. The linear range of 10 detected compounds were good (r≥0.999 7), and the overall recoveries ranged from 96.30% to 103.0%, with the RSD ranging from 0.72% to 2.9%. The method was simple, accurate and reproducible, which can be used for the simultaneous determination of the content of ten major components in P. hookeri. Copyright© by the Chinese Pharmaceutical Association.
[Serum pharmacochemistry of Qinbai Qingfei concentrated pellets based on UPLC-Q-TOF-MS].
Liu, Ye; Wei, Wen-Feng; Huo, Jin-Hai; Wang, Wei-Ming
2017-02-01
To analyze the main components of Qinbai Qingfei concentrated pellets in rat serum with UPLC-Q-TOF-MS technology and serum pharmacochemistry theory. After gavage administration with Qinbai Qingfei concentrated pellets, blood was collected from hepatic portal vein. ACQUITY UPLC BEH C₁₈(2.1 mm×100 mm, 1.7 μm) was used, with 0.1% formic acid agueous solution(A)-0.1%formic acid and acetonitrile(B) as the mobile phase for gradient elution. The flow rate was 0.3 mL•min⁻¹, the column temperature was maintained at 35 ℃. Through the comparative analysis fingerprints of Qinbai Qingfei concentrated pellets, drug containing-serum and blank serum, and with the help Peakview and Metabolitepilot software, components in serum were defined. A total of 28 compounds were identified, including 18 prototypes and 10 metabolites. As a result, UPLC-Q-TOF-MS technology and serum pharmacochemistry theory were applied to comprehensively expound Qinbai Qingfei concentrated pellets'constituents migrating to rat serum, and provide scientific basis for further studies for in vivo metabolic process and effective material base. Copyright© by the Chinese Pharmaceutical Association.
Ogawa, Tadashi; Hattori, Hideki; Kaneko, Rina; Ito, Kenjiro; Iwai, Masae; Mizutani, Yoko; Arinobu, Tetsuya; Ishii, Akira; Seno, Hiroshi
2011-06-01
In this report, a high-throughput and sensitive method for analysis of eight central-acting muscle relaxants in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) in the positive and negative ionization modes using tolbutamide as internal standard is presented. After pretreatment of a plasma sample by solid-phase extraction with an Oasis HLB cartridge, muscle relaxants were analyzed by UPLC with Acquity UPLC BEH C(18) column and Acquity TQD tandem quadrupole mass spectrometer equipped with an electrospray ionization interface. The calibration curves for muscle relaxants spiked into human plasma equally showed good linearities in the nanogram per milliliter order range. The detection limits (signal-to-noise ratio = 3) was as low as 0.1-2 ng/mL. The method gave satisfactory recovery rates, accuracy, and precision for quality control samples spiked with muscle relaxants. To further validate the present method, 250 mg of chlorphenesin carbamate was orally administered to a healthy male volunteer, and the concentrations of chlorphenesin carbamate in plasma were measured 0.5, 1, 2, 4, 6, and 8 h after dosing; their concentrations in human plasma were between 0.62 and 2.44 μg/mL. To our knowledge, this is the first report describing simultaneous analysis of over more than two central-acting muscle relaxants by liquid chromatography-tandem mass spectrometry. This has been realized by the capability of our instrument for simultaneous multiple reaction monitoring of the target compounds in both positive and negative ionization modes. Therefore, the present method seems very useful in forensic and clinical toxicology and pharmacokinetic studies.
NASA Astrophysics Data System (ADS)
Balaji, Jayagopal; Shivashankar, Murugesh
2017-11-01
The present study describes a simple and robust reverse phase ultra performance liquid chromatography (RP-UPLC) method for the quantification of 5-amino salicyclic acid in 5-amino salicyclic acid rectal capsules. Successful separation of Mesalamine peak from excipient peaks and diluent were achieved on a Acquity C8 (50 × 2.1 mm, 1.7 μm) and UV detector at 254 nm, 0.3 mL/min as a flow rate, and 3 μL as an injection volume. For the RP-UPLC method, phosphate buffer and methanol was used as mobile phases at ratio of 83:17 and the column temperature was 25 °C. Percentage recovery obtained in the range of 98.7 - 99.7 % and the method is linear for Mesalamine for specified concentration range with coefficient of variation (r) not less than 0.99. The proposed RP-UPLC method was found to be specific, linear, precise, accurate and robust.
Qiu, Xiangjun; Zhao, Jian-Long; Hao, Cong; Yuan, Canli; Tian, Nuan; Xu, Zhi-Sheng; Zou, Ruan-Min
2016-05-30
In this study, a sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed to determine mangiferin and neomangiferin in rat plasma simultaneously. Chromatographic separation was carried out on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a Xevo TQD triple quadruple mass spectrometer coupled with an electrospray ionization (ESI) source. The MRM transitions of m/z 423.2 → 303.1 and m/z 585.0 → 273.1 were used to quantify for mangiferin and neomangiferin, respectively. The linearity of this method was found to be within the concentration range of 5-2000 ng/mL for mangiferin, and 2-1000 ng/mL for neomangiferin in rat plasma, respectively. Only 3.0 min was needed for an analytical run. This assay was used to support a preclinical study to investigate the pharmacokinetics of mangiferin and neomangiferin in rats. Copyright © 2016 Elsevier B.V. All rights reserved.
Pietrogrande, Maria Chiara; Dondi, Francesco; Ciogli, Alessia; Gasparrini, Francesco; Piccin, Antonella; Serafini, Mauro
2010-06-25
In this study, a comparative investigation was performed of HPLC Ascentis (2.7 microm particles) columns based on fused-core particle technology and Acquity (1.7 microm particles) columns requiring UPLC instruments, in comparison with Chromolith RP-18e columns. The study was carried out on mother and vegetal tinctures of Passiflora incarnata L. on one single or two coupled columns. The fundamental attributions of the chromatographic profiles are evaluated using a chemometric procedure, based on the AutoCovariance Function (ACVF). Different chromatographic systems are compared in terms of their separation parameters, i.e., number of total chemical components (m(tot)), separation efficiency (sigma), peak capacity (n(c)), overlap degree of peaks and peak purity. The obtained results show the improvements achieved by HPLC columns with narrow size particles in terms of total analysis time and chromatographic efficiency: comparable performance are achieved by Ascentis (2.7 microm particle) column and Acquity (1.7 microm particle) column requiring UPLC instruments. The ACVF plot is proposed as a simplified tool describing the chromatographic fingerprint to be used for evaluating and comparing chemical composition of plant extracts by using the parameters D% - relative abundance of the deterministic component - and c(EACF) - similarity index computed on ACVF. Copyright 2010 Elsevier B.V. All rights reserved.
Sun, Yichun; Xue, Juan; Li, Baimei; Lin, Xiaoting; Wang, Zhibin; Jiang, Hai; Zhang, Hongwei; Wang, Qiuhong; Kuang, Haixue
2016-11-01
A rapid, sensitive, and reliable analytical ultra performance liquid chromatography with tandem mass spectrometry method was developed for the simultaneous determination of Aralia-saponin IV, 3-O-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl-(1→3)-β-d-glucopyranosyl oleanolic acid 28-O-β-d-glucopyranoside, Aralia-saponin A and Aralia-saponin B after the oral administration of total saponin of Aralia elata leaves in rat plasma. Plasma samples were pretreated by protein precipitation with methanol. The analysis was performed on an ACQUITY UPLC HSS T3 column. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring mode using an electrospray ionization source with negative ionization mode. Under the experimental conditions, the calibration curves of four analytes had good linearity values (r > 0.991). The intra- and inter-day precision values of the four analytes were ≤ 11.6%, and the accuracy was between -6.2 and 4.2%.The extraction recoveries of four triterpenoid saponins were in the range of 84.06-91.66% (RSD < 10.5%), and all values of the matrix effect were more than 90.30%. The developed analytical method was successfully applied to pharmacokinetic study on simultaneous determination of the four triterpenoid saponins in rat plasma after oral administration of total saponin of Aralia elata leaves, which helps guiding clinical usage of Aralia elata leaves. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sharma, Upendra K; Sharma, Nandini; Sinha, Arun K; Kumar, Neeraj; Gupta, Ajai P
2009-10-01
In this study, two novel chromatographic methods based on monolithic column high-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were developed for the ultrafast determination of principal flavor compounds namely vanillin, vanillic acid, p-hydroxybenzoic acid, and p-hydroxybenzaldehyde in ethanolic extracts of Vanilla planifolia pods. Good separation was achieved within 2.5 min using Chromolith RP18e column (100 mm x 4.6 mm) for HPLC and Acquity BEH C-18 (100 mm x 2.1 mm, 1.7 microm) column for UPLC. Both methods were compared in terms of total analysis time, mobile phase consumption, sensitivity, and validation parameters like precision, accuracy, LOD, and LOQ. Further, system suitability test data including resolution, capacity factor, theoretical plates, and tailing factor was determined for both the methods by ten replicate injections. Monolithic column based HPLC gave better results for most of the selected parameters while UPLC was found to be more eco-friendly with low mobile phase consumption and better sensitivity. Both methods may be used conveniently for the high throughput analysis of large number of samples in comparison to traditional particulate column.
Qin, Feng; Huang, Jun; Qiu, Xinjian; Hu, Sihang; Huang, Xi
2011-01-01
A simple, sensitive, and reliable ultra-performance liquid chromatography (UPLC) method has been developed for simultaneous determination of 22 major constituents in modified xiaoyao san (MXS), a multiherbal formula. The chromatographic separation was performed on an ACQUITY UPLC BEH C18 column (150 x 2.1 mm, 1.7 microm, particle size), with an aqueous 0.5% acetic acid and acetonitrile mobile phase gradient. The method was validated for linearity (r2 >0.9937), intraday and interday precision (RSD <8.51%), recovery (91.18-107.73%), LOD (0.02-4.17 ng/mL), and LOQ (0.05-12.50 ng/mL). The established method was successfully applied to quantify the 22 marker compounds in MXS, which provided a useful basis of overall evaluation of the quality of MXS.
Zhang, Hui-ye; Xu, Xiao-fei; Huang, Yong; Wamg, De-qin; Deng, Qiao-hua
2014-06-01
To establish an analytical method for characteristic fingerprint and determination of main components of Andrographis paniculata Extract by UPLC. The chromatographic conditions were Waters ACQUITY UPLC BEH-C18 (2. 1 mm x 0 mm,1.7 μm)by gradient elute using acetonitrile-water as mobile phase(0 -2 min,20% ~ 25% A;2 ~ 5 min,25% ~ 35% A;5 ~ 7 min,35% A;7 ~10 min,35%~ 55% A) at a flow rate of 0. 5 min/mL,detecting wavelength at 220 nm. Results:Contents of the andrographolide, neoandrographolide, 14-deoxyandrographolide and 14-deoxy-l11,12-didehydroandrographolide had good resolution with the correlation coefficients exceed 0. 9999 and the average percent recovery lied in 97. 2% to 103.9%, RSD was less than 3.0% (n = 6). The chromatograms of Andrographis paniculata Extract shared seven common peaks in which four of them were recognized by reference standard with the similarities over 0. 9. It is a fast,accurate and validated method,and can be useful in quality evaluations of Andrographis paniculata Extract.
[Determination of terpene lactones in Ginkgo biloba leaves in different ages by UPLC-TQ-MS].
Yao, Xin; Zhou, Gui-Sheng; Tang, Yu-Ping; Qian, Ye-Fei; Shang, Er-Xin; Su, Shu-Lan; Qian, Da-Wei; Duan, Jin-Ao
2013-02-01
To establish an ultra-high performance liquid chromatography coupled with triple quadrupole mass (UPLC-TQ-MS) for determination of four terpene lactones. Chromatographic separation was carried out on a ACQUITY UPLC BEH C18 column (2.1 mm x 100 mm, 1.7 microm) with isocratic elution of 70% methanol at a flow rate of 0.4 mL x min(-1), the column temperature was set at 30 degrees C; Waters Xevo TQ worked in multiple reaction monitoring mode. All calibration curves were linear (r > 0.990 3) over the tested ranges. The average recoveries ranged from 98.83% to 103.9% with RSD value below 3.0%. The contents of total terpene lactones in Ginkgo biloba leaves were significantly different in different ages. The contents in the leaves of young ginkgo tree were higher than that in old tree. The method was simple and fast with high precision, sensitivity and repeatability, which can be used for qualitative and quantitative analysis of terpene lactones in G. biloba leaves.
Determination and pharmacokinetic study of Enasidenib in rat plasma by UPLC-MS/MS.
Pang, Ni-Hong; Liu, Qian; Lu, Xiang-Ran; Yang, Su-Fen; Lin, Dong-Dong; Hu, Guo-Xin
2018-04-27
Enasidenib, an oral product for treating Acute Myeloid Leukemia, has been approved by FDA in Aug, 2017. In this study, we set up an ultra-performance liquid chromatography-mass spectrometry (UPLC-MS/MS) method for measuring Enasidenib and imatinib (internal standard, IS), simultaneously. Enasidenib and imatinib were separated on an ACQUITY UPLC BEH C 18 Column (2.1 mm × 50 mm, 1.7 μm, 132 Å). Mass detection was carried out by electrospray ionization in the position mode, and the multiple reaction monitoring transitions were m/z 474.23 → 456.17 and m/z 494.30 → 394.20 for Enasidenib and imatinib, respectively. Linearity (2 - 500 ng·mL -1 , R 2 > 0.999), precision and accuracy (RE < ± 15%), extraction recovery (≥ 96.69%), matrix effect (≥ 96.47%) and stability (RE < ± 10%) were validated which demonstrated the robustness of our method. This rapid, efficient and reliable UPLC-MS/MS method shows specificity and repeatability of Enasidenib in rat plasma and can be used in further pharmacokinetic studies. Copyright © 2018 Elsevier B.V. All rights reserved.
Tao, Huang; Yun-Hai, Guo; He-Xiang, Liu; Yi, Zhang
2018-04-19
To establish a method for the quantitative determination of serotonin and dopamine in the nervous system of Biomphalaria glabrata by using ultra high performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC MS/MS) . The B. glabrata nervous system was broken in the pure methanol solution after obtaining it by dissecting with microscope. Then, the supernatant containing the target substance after twice high speed centrifugation was got. The extraction was separated on an ACQUITY UPLC BEH Amide column with Waters TQ-XS series mass spectrometry detector, with ESI source and positive electrospray ionization mode when the machine testing. The detection limit of serotonin was 0.03 ng/ml and the limit of quantification was 0.1 ng/ml. The detection limit of dopamine was 0.05 ng/ml and the limit of quantification was 0.15 ng/ml. The recoveries of serotonin ranged from 90.68% to 94.72% over the range of 1 to 40 ng/ml. The recoveries of dopamine ranged from 91.68% to 96.12% over the range of 1.0 ng/ml to 40 ng/ml. The established UPLC MS/MS method is simple, stable and reproducible. It can be used for the quantitative analysis of serotonin and dopamine in the nervous system of B. glabrata snails.
Ultrafast quantification of β-lactam antibiotics in human plasma using UPLC-MS/MS.
Carlier, Mieke; Stove, Veronique; De Waele, Jan J; Verstraete, Alain G
2015-01-26
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a fast ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, cefuroxime, ceftazidime, meropenem and piperacillin with minimal turn around time. Sample clean-up included protein precipitation with acetonitrile containing 5 deuterated internal standards, and subsequent dilution of the supernatant with water after centrifugation. Runtime was only 2.5 min. Chromatographic separation was performed on a Waters Acquity UPLC system using a BEH C18 column (1.7 μm, 100 mm × 2.1 mm) applying a binary gradient elution of water and methanol both containing 0.1% formic acid and 2 mmol/L ammonium acetate on a Water TQD instrument in MRM mode. All compounds were detected in electrospray positive ion mode and could be quantified between 1 and 100 mg/L for amoxicillin and cefuroxime, between 0.5 and 80 mg/L for meropenem and ceftazidime, and between 1 and 150 mg/L for piperacillin. The method was validated in terms of precision, accuracy, linearity, matrix effect and recovery and has been compared to a previously published UPLC-MS/MS method. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Hong; Gao, Yu-Mei; Zhang, Jing; Wang, Lin; Wang, Xiao-Xin
2013-01-01
Objective: To establish an ultra-performance liquid chromatography (UPLC) fingerprinting method for quality control of Phragmitis rhizoma from Baiyangdian. Materials and Methods: Ultrasonic extraction with 70% methanol was performed on 10 samples of P. rhizoma collected from 10 different villages in Baiyangdian. The sample solutions were analyzed by Waters UPLC equipped with the ACQUITY UPLC BEH C18 column and photodiode array (PDA) detector, and gradient eluted with acetonitrile/water as the mobile phase. The flow rate was set to 0.1 mL/min; the column temperature was set to 25°C; and the detection wavelength was set to 285 nm. Results: The chromatograms of the 10 samples showed 27 common peaks, of which one was identified as the ferulic acid standard. The similarity indexes were all above 0.82. Hierarchical cluster analysis showed that the constituents and their quantities differed according to the diameter of the original plant, which is related to its age. Conclusion: The UPLC fingerprinting method had the advantages of being fast, accurate, and highly efficient; this indicated that it can be used for quality control of P. rhizoma produced in Baiyangdian. Also, the relation between the quality and diameter/age of the plant needs to be further investigated. PMID:24124278
Dubey, Sunil Kumar; Saha, R N; Jangala, Hemanth; Pasha, S
2013-12-01
A new ultra-performance liquid chromatography-electrospray ionization mass spectrometry (UPLC-MS/ESI) method for simultaneous determination of venlafaxine (VEN) and its metabolite O-desmethylvenlafaxine (ODV) in rat plasma has been developed and validated using Venlafaxine d6 as the internal standard. The compounds and internal standard were extracted from plasma by solid phase extraction. The UPLC separation of the analytes was performed on ACQUITY UPLC ® BEH Shield RP18 (1.7 µm, 100 mm×2.1 mm) column, using isocratic elution with mobile phase constituted of water (containing 2 mM ammonium acetate): acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. All of the analytes were eluted within 1.5 min. The compounds were ionized in the electrospray ionization (ESI) ion source of the mass spectrometer, operating in multiple reaction monitoring (MRM) and positive ion mode. The precursor to product ion transitions monitored for VEN, ODV and Venlafaxine d6 were m / z 278.3→121.08, 264.2→107.1 and 284.4→121.0, respectively. The developed and validated method was used for the pharmacokinetic study of VEN in rats.
Flint, Robert B; Mian, Paola; van der Nagel, Bart; Slijkhuis, Nuria; Koch, Birgit C P
2017-04-01
Acetaminophen (APAP, paracetamol) is the most commonly used drug for pain and fever in both the United States and Europe and is considered safe when used at registered dosages. Nevertheless, differences between specific populations lead to remarkable changes in exposure to potentially toxic metabolites. Furthermore, extended knowledge is required on metabolite formation after intoxication, to optimize antidote treatment. Therefore, the authors aimed to develop and validate a quick and easy analytical method for simultaneous quantification of APAP, APAP-glucuronide, APAP-sulfate, APAP-cysteine, APAP-glutathione, APAP-mercapturate, and protein-derived APAP-cysteine in human plasma by ultraperformance liquid chromatography-electrospray ionization-tandem mass spectrometry. The internal standard was APAP-D4 for all analytes. Chromatographic separation was achieved with a reversed-phase Acquity ultraperformance liquid chromatography HSS T3 column with a runtime of only 4.5 minutes per injected sample. Gradient elution was performed with a mobile phase consisting of ammonium acetate, formic acid in Milli-Q ultrapure water or in methanol at flow rate of 0.4 mL/minute. A plasma volume of only 10 μL was required to achieve both adequate accuracy and precision. Calibration curves of all 6 analytes were linear. All analytes were stable for at least 48 hours in the autosampler; the high quality control of APAP-glutathione was stable for 24 hours. The method was validated according to the U.S. Food and Drug Administration guidelines. This method allows quantification of APAP and 6 metabolites, which serves purposes for research, as well as therapeutic drug monitoring. The advantage of this method is the combination of minimal injection volume, a short runtime, an easy sample preparation method, and the ability to quantify APAP and all 6 metabolites.
Hu, Fangdi; An, Jing; Li, Wen; Zhang, Zijia; Chen, Wenxia; Wang, Changhong; Wang, Zhengtao
2015-07-01
Eucommiae cortex (EC), the bark of Eucommia ulmoides Oliv., has been traditionally used to treat many diseases in China for more than 2000 years. The pharmacological effects are primarily attributed to the presence of lignans, iridoids and phenolics, which are main active ingredients in EC. First, to investigate the active ingredients that can be absorbed into the rat plasma according to which ingredients exhibit significant correlation of drug concentration-time curve. Second, to establish an efficient ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for simultaneous determination of ingredients absorbed in rat plasma. Finally, to investigate gender effect on the pharmacokinetics of the ingredients absorbed in male and female rats plasma after oral administration with EC extract. 18 ingredients from EC were detected by UPLC-MS/MS, 9 out of 18 ingredients were absorbed into rat plasma. And 5 ingredients exhibit significant correlation of drug concentration-time curve. They were pinoresinol di-O-β-d-glucopyranoside (PDG), geniposide (GE), geniposidic acid (GA), aucubin (AN) and chlorogenic acid (CA). The analytes were extracted from rat plasma via a simple protein precipitation procedure and osalmid was used as the internal standard. Chromatographic separation was achieved on a Waters ACQUITY HSS T3 column (2.1mm×100mm, 1.8μm) using a gradient elution program with acetonitrile and 0.1% formic acid water as the mobile phase, with a flow rate of 0.3mLmin(-1). The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reactions monitoring (MRM) mode in a positive ion mode via electrospray ionization (ESI). The transition monitored were /z 683.00[M+H](+)→235.10 for PDG, / z 389.00[M+H](+)→208.80 for GE, m/z 375.00[M+H](+)→194.79 for GA, m/z 364.00[M+NH4](+)→148.81 for AN, m/z 355.10[M+H](+)→162.84 for CA and m/z 230.03[M+H](+)→120.77 for internal standard. The developed method showed good linearity over a wide concentration range, the lower limits of quantification and higher accuracy and precision for determination of the 5 analytes. Then the method was applied to study the pharmacokinetics in rats, and the results indicated that there were significant differences in pharmacokinetic parameters of the analytes between the male and female rats, and absorptions of these analytes in male group were all significantly higher than those in female group. This study established an efficient, sensitive and selective UPLC-MS/MS method for simultaneous determination of the five ingredients in rat plasma, and it could be successfully applied to the comparative pharmacokinetic studies in male and female rats after oral administration with EC extract. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
[Comparison of chemical composition between fresh and processed Bufonis Venenum by UPLC-TQ-MS].
Wang, Zi-yue; Wang, Hong-lan; Zhou, Jing; Ma, Hong-yue; Gong, Yan; Yan, Wen-li; Qian, Da-wei
2015-10-01
Toad venom is the Bufo bufo gargarizans or B. melanostictus after the ears of the gland secretion, used in the treatment of various cancers in recent years. Research shows that the main anti-tumor components in bufadienolide. Bufadienolide have free type structure and conjunct type structure. To identify and clarify the difference between bufogenin and bufotoxin contained in Bufonis Venenum, which was from B. bufo gargarizans, an UPLC-TQ-MS method has been established. UPLC-TQ-MS method was used to identify and quantify the major bufadienolides in Bufonis Venenum. UPLC-TQ-MS assay with positive ion mode was performed on a Waters ACQUITY UPLC BEH C, (2.1 mm x 100 mm, 1.7 µm) with the mobile phase consisting of 0. 1% aqueous formic and acidacetonitrile in gradient elution at a flow rate of 0.4 mL · min⁻¹ and the column temperature was set at 35 °C. By comparing their retention time and high resolution mass data of Bufonis Venenum extracts, 37 effective components were primarily identified by MS/MS analysis in positive ion mode. Twenty-six of them were free-type bufadienolides (bufogenin), 11 of them were conjugated bufadienolides. There were significant differences in the main composition between fresh and processed Bufonis Venenum. The study found that the chemical composition of toad venom through great changes after processing, conjunct type content is much less, free type content as well change.
Bihan, Kevin; Sauzay, Chloé; Goldwirt, Lauriane; Charbonnier-Beaupel, Fanny; Hulot, Jean-Sebastien; Funck-Brentano, Christian; Zahr, Noël
2015-02-01
Vemurafenib (Zelboraf) is a new tyrosine kinase inhibitor that selectively targets activated BRAF V600E gene and is indicated for the treatment of advanced BRAF mutation-positive melanoma. We developed a simple method for vemurafenib quantification using liquid chromatography-tandem mass spectrometry. A stability study of vemurafenib in human plasma was also performed. (13)C(6)-vemurafenib was used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. Chromatography was performed on an Acquity UPLC system (Waters) with chromatographic separation by the use of an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7-mm particle size; Waters). Quantification was performed using the monitoring of multiple reactions of following transitions: m/z 488.2 → 381.0 for vemurafenib and m/z 494.2 → 387.0 for internal standard. This method was linear over the range from 1.0 to 100.0 mcg/mL. The lower limit of quantification was 0.1 mcg/mL for vemurafenib in plasma. Vemurafenib remained stable for 1 month at all levels tested, when stored indifferently at room temperature (20 °C), at +4 °C, or at -20 °C. This method was used successfully to perform a plasma pharmacokinetic study of vemurafenib in a patient after oral administration at a steady state. This liquid chromatography-tandem mass spectrometry method for vemurafenib quantification in human plasma is simple, rapid, specific, sensitive, accurate, precise, and reliable.
Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G
2012-11-01
There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Qian, Feizhong; Zhu, Libo; Xu, Nengbin; Feng, Jiayong; Hong, Zhengfang; Xu, Lihong; Chen, Zhongquan; Wang, Shengle
2014-05-01
An ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/ MS) method was developed for the determination of picric acid and its reductive transformation product picramic acid in aqueous samples. A hydrophilic interaction liquid chromatography (HILIC) column (Acquity UPLC BEH HILIC; 100 mm x 2.1 mm, 1.7 microm) was used for the separation. Surface water samples could be injected into the UPLC system just after being filtered through a 0.2 microm membrane. The satisfactory recoveries of picric acid and picramic acid were in the range of 89% - 107%. Waste water samples were purified by solid phase extraction (SPE), and then were analyzed. The recoveries of picric acid and picramic acid in waste water were 72%-101%. The reproducibility of the method was good with the RSDs of 4.9% - 14.7%. The limits of detection (LODs) of picric acid and picramic acid were 0.1 microg/L and 0.3 microg/L, respectively. This proposed method is rapid, highly specific and suitable for the confirmation and quantitative determination of picric acid and picramic acid in surface water and waste water.
Miller, Tricia M; Poloyac, Samuel M; Anderson, Kacey B; Waddell, Brooke L; Messamore, Erik; Yao, Jeffrey K
2017-01-18
A rapid and sensitive method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed to simultaneously quantify hydroxyeicosatetraenoic (HETE), dihydroxyeicosatrienoic (DiHETrE), epoxyeicosatrienoic acid (EET), and prostaglandin metabolites of arachidonic acid in human plasma. Sample preparation consisted of solid phase extraction with Oasis HLB (30mg) cartridges for all metabolites. Separation of HETEs, EETs, and DiHETrEs was achieved on an Acquity UPLC BEH C18, 1.7µm (100×2.1mm) reversed-phase column (Waters Corp, Millford, MA) with negative electrospray ionization mass spectrometric detection. A second injection of the same extracted sample allowed for separation and assessment of prostaglandin metabolites under optimized UPLC-MS/MS conditions. Additionally, the endogenous levels of these metabolites in five different matrices were determined in order to select the optimal matrix for assay development. Human serum albumin was shown to have the least amount of endogenous metabolites, a recovery efficiency of 79-100% and a matrix effect of 71 - 100%. Linear calibration curves ranging from 0.416 to 66.67ng/ml were validated. Inter-assay and intra-assay variance was less than 15% at most concentrations. This method was successfully applied to quantify metabolite levels in plasma samples of healthy control subjects receiving niacin administration to evaluate the association between niacin administration and eicosanoid plasma level response. Published by Elsevier Ltd.
Boelaert, Jente; Schepers, Eva; Glorieux, Griet; Eloot, Sunny; Vanholder, Raymond; Lynen, Frédéric
2016-05-13
Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide (NO) synthesis, and its structural isomer symmetric dimethylarginine (SDMA) are uremic toxins accumulating in chronic kidney disease (CKD) patients. The objective of this study was to develop and validate a robust UPLC-MS/MS method for the simultaneous determination of ADMA and SDMA in human serum. Chromatographic separation after butyl ester derivatization was achieved on an Acquity UPLC BEH C18 column, followed by tandem mass spectrometric detection. After validation, the applicability of the method was evaluated by the analysis of serum samples from 10 healthy controls and 77 CKD patients on hemodialysis (CKD5HD). Both ADMA (0.84 ± 0.19 µM vs. 0.52 ± 0.07 µM) and SDMA concentrations (2.06 ± 0.82 µM vs. 0.59 ± 0.13 µM) were significantly (p < 0.001) elevated in CKD5HD patients compared to healthy controls. In general, low degrees of protein binding were found for both ADMA and SDMA. In addition, an established commercially available ELISA kit was utilized on the same samples (n = 87) to compare values obtained both with ELISA and UPLC-MS/MS. Regression analysis between these two methods was significant (p < 0.0001) but moderate for both ADMA (R = 0.78) and SDMA (R = 0.72).
Determination and pharmacokinetic study of pirfenidone in rat plasma by UPLC-MS/MS.
Sun, Wei; Jiang, Zhe-li; Zhou, Lei; Chen, Rui-min; Wang, Zhe; Li, Wan-shu; Jiang, Shuo-min; Hu, Guo-xin; Chen, Rui-jie
2015-02-15
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the determination and pharmacokinetic investigation of pirfenidone in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2 mL of acetonitrile to a 0.1 mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0 min and the elution of pirfenidone was at 1.39 min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 186.2→92.1 for pirfenidone and m/z 237.1→194.2 for carbamazepine (IS), respectively. The calibration curve was linear over the range of 5-2000 ng/mL with a lower limit of quantitation (LLOQ) of 5 ng/mL. Mean recovery of pirfenidone in plasma was in the range of 80.4-84.3%. Intra-day and inter-day precision were both <12.1%. This method was successfully applied in pharmacokinetic study after oral administration of 10.0mg/kg pirfenidone in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Kong, Weijun; Jin, Cheng; Xiao, Xiaohe; Zhao, Yanling; Liu, Wei; Li, Zulun; Zhang, Ping
2010-06-01
A fast ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) method was established for simultaneous quantification of seven components in natural Calculus bovis (C. bovis) and its substitutes or spurious breeds. On a Waters Acquity UPLC BEH C(18) column, seven analytes were efficiently separated using 0.2% aqueous formic acid-acetonitrile as the mobile phase in a gradient program. The evaporator tube temperature of ELSD was set at 100 degrees C with the nebulizing gas flow-rate of 1.9 L/min. The results showed that this established UPLC-ELSD method was validated to be sensitive, precise and accurate with the LODs of seven analytes at 2-11 ng, and the overall intra-day and inter-day variations less than 3.0%. The recovery of the method was in the range of 97.8-101.6%, with RSD less than 3.0%. Further results of PCA on the contents of seven investigated analytes suggested that compounds of cholic acid, deoxycholic acid and chenodeoxycholic acid or cholesterol should be added as chemical markers to UPLC analysis of C. bovis samples for quality control and to discriminate natural C. bovis sample and its substitutes or some spurious breeds, then normalize the use of natural C. bovis and ensure its clinical efficacy.
Avula, Bharathi; Wang, Yan-Hong; Smillie, Troy J; Khan, Ikhlas A
2009-03-01
A UPLC-UV/ELSD method has been developed for analysis of major triterpenoids and formononetin in ACTAEA RACEMOSA L. (family Ranunculaceae) samples. The best results were obtained with an Acquity UPLC BEH C18 (100 mmx2.1 mm, i. d., 1 microm) column system using gradient elution with a mobile phase consisting of water and acetonitrile:methanol (7:3) at a constant flow rate of 0.3 mL/min. Owing to their low UV absorption, the triterpene saponins were detected by evaporative light scattering. Within 5.5 minutes, three main triterpenoid glycosides [cimiracemoside A, 23- EPI-26-deoxyactein, and actein] and an isoflavonoid, formononetin, could be separated, with detection limits of 5, 5, 10, and 0.01 microg/mL, respectively. The method was successfully used to analyze different Actaea racemosa market products as well as to distinguish between two other ACTAEA species. There was a significant variability in the amounts of the selected triterpene glycosides for the products containing black cohosh and rhizomes of black cohosh. The isoflavone formononetin was not detected in the samples analyzed. LC-MS coupled with the electrospray ionization (ESI) interface method is described for the identification of formononetin and triterpenoid glycosides in plant samples and dietary supplements that claim to contain black cohosh and different species of Actaea.
Tian, Jingzhi; Rustum, Abu
2018-02-01
Imidacloprid is used as an active pharmaceutical ingredient (API) in veterinary drugs to control fleas and ticks for dogs and cats. Here we are reporting for the first time a validated stability-indicating reversed-phase UPLC-UV method for the assay of imidacloprid and estimation of its related compounds. The stability-indicating capability of this method has been demonstrated by a forced degradation study. All related compounds including processing impurities, imidacloprid API and degradates from stressed samples were well separated from each other. Structures of major degradates from forced degradation study were elucidated through UPLC-MS/MS and key degradation pathways were proposed from the proposed chemical structures of major degradates. The UPLC-UV method is carried out using an HSS T3 column (C18, 2.1 × 30 mm, 1.8 μm particle size) maintained at 30°C with mobile phase A (0.05% v/v of phosphoric acid in water) and mobile phase B (methanol/acetonitrile 75/25 v/v). Analytes are separated by a gradient elution and detected at 270 nm. The UPLC method is green and fast with only 6.5 min run time and about 3.5 ml mobile phase consumption for each sample analysis. The UPLC-UV method was validated according to ICH guidelines. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula L N; Ramaiah, Parimi Atchuta
2012-01-01
A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one.
Yanamandra, Ramesh; Vadla, Chandra Sekhar; Puppala, Umamaheshwar; Patro, Balaram; Murthy, Yellajyosula. L. N.; Ramaiah, Parimi Atchuta
2012-01-01
A new rapid, simple, sensitive, selective and accurate reversed-phase stability-indicating Ultra Performance Liquid Chromatography (RP-UPLC) technique was developed for the assay of Tolterodine Tartrate in pharmaceutical dosage form, human plasma and urine samples. The developed UPLC method is superior in technology to conventional HPLC with respect to speed, solvent consumption, resolution and cost of analysis. Chromatographic run time was 6 min in reversed-phase mode and ultraviolet detection was carried out at 220 nm for quantification. Efficient separation was achieved for all the degradants of Tolterodine Tartrate on BEH C18 sub-2-μm Acquity UPLC column using Trifluoroacetic acid and acetonitrile as organic solvent in a linear gradient program. The active pharmaceutical ingredient was extracted from tablet dosage form using a mixture of acetonitrile and water as diluent. The calibration graphs were linear and the method showed excellent recoveries for bulk and tablet dosage form. The test solution was found to be stable for 40 days when stored in the refrigerator between 2 and 8 °C. The developed UPLC method was validated and meets the requirements delineated by the International Conference on Harmonization (ICH) guidelines with respect to linearity, accuracy, precision, specificity and robustness. The intra-day and inter-day variation was found be less than 1%. The method was reproducible and selective for the estimation of Tolterodine Tartrate. Because the method could effectively separate the drug from its degradation products, it can be employed as a stability-indicating one. PMID:22396907
Bjørk, Marie Kjærgaard; Simonsen, Kirsten Wiese; Andersen, David Wederkinck; Dalsgaard, Petur Weihe; Sigurðardóttir, Stella Rögn; Linnet, Kristian; Rasmussen, Brian Schou
2013-03-01
An efficient method for analyzing illegal and medicinal drugs in whole blood using fully automated sample preparation and short ultra-high-performance liquid chromatography-tandem mass spectrometry (MS/MS) run time is presented. A selection of 31 drugs, including amphetamines, cocaine, opioids, and benzodiazepines, was used. In order to increase the efficiency of routine analysis, a robotic system based on automated liquid handling and capable of handling all unit operation for sample preparation was built on a Freedom Evo 200 platform with several add-ons from Tecan and third-party vendors. Solid-phase extraction was performed using Strata X-C plates. Extraction time for 96 samples was less than 3 h. Chromatography was performed using an ACQUITY UPLC system (Waters Corporation, Milford, USA). Analytes were separated on a 100 mm × 2.1 mm, 1.7 μm Acquity UPLC CSH C(18) column using a 6.5 min 0.1 % ammonia (25 %) in water/0.1 % ammonia (25 %) in methanol gradient and quantified by MS/MS (Waters Quattro Premier XE) in multiple-reaction monitoring mode. Full validation, including linearity, precision and trueness, matrix effect, ion suppression/enhancement of co-eluting analytes, recovery, and specificity, was performed. The method was employed successfully in the laboratory and used for routine analysis of forensic material. In combination with tetrahydrocannabinol analysis, the method covered 96 % of cases involving driving under the influence of drugs. The manual labor involved in preparing blood samples, solvents, etc., was reduced to a half an hour per batch. The automated sample preparation setup also minimized human exposure to hazardous materials, provided highly improved ergonomics, and eliminated manual pipetting.
Zhao, Ai-qin; Zhao, Ji-hong; Zhang, Shu-qing; Pan, Yong-yang; Huo, Xu-lei
2016-02-05
A rapid, sensitive and selective ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the determination and pharmacokinetic investigation of parthenolide in rat plasma. Sample preparation was accomplished through a simple one-step deproteinization procedure with 0.2mL of acetonitrile containing 30ng/mL of pirfenidone (IS), and to a 0.1mL plasma sample. Plasma samples were separated by UPLC on an Acquity UPLC BEH C18 column using a mobile phase consisting of acetonitrile-0.1% formic acid in water with gradient elution. The total run time was 3.0min and the elution of parthenolide was at 1.33min. The detection was performed on a triple quadrupole tandem mass spectrometer in the multiple reaction-monitoring (MRM) mode using the respective transitions m/z 249.2→231.1 for parthenolide and m/z 186.2→92.1 for pirfenidone (IS), respectively. The calibration curve was linear over the range of 2.0-500ng/mL with a lower limit of quantitation (LLOQ) of 2.0ng/mL. Mean recovery of parthenolide in plasma was in the range of 78.2-86.6%. Intra-day and inter-day precision were both <8.3%. This method was successfully applied in pharmacokinetic study after oral and intravenous administration of parthenolide in rats. Copyright © 2015 Elsevier B.V. All rights reserved.
Qin, Zhen-Xian; Zhang, Yu; Qi, Meng-Die; Zhang, Quan; Liu, Shuang; Li, Ming-Hui; Liu, Yong-Gang; Liu, Yong
2016-04-01
The study is aimed to analyze the chemical components in leaves of Chinese seabuckthorn and Tibetan seabuckthorn qualitatively and compare the differences between them by using ultra performance liquid chromatography coupled with quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS).The chromatographic separation of the components was achieved ona Waters ACQUITY UPLC-T3 column (2.1 mm×100 mm, 1.7 μm)using gradient mobile phase consisting of acetonitrile (A) and aqueous solution (B). The identification of the separated compounds was performed on atandem mass spectrometry (MS/MS)by fragmentation patterns under the negative electrospray ionization. The parameters of ion source were as follows:capillary voltage, 2 000 V; Cone voltage, 40 V. The ion source temperature, 100 ℃; collision gas argon; sheath gas flow rate, 900 L•h⁻¹; sheath gas temperature, 450 ℃. Through the analysis of mass spectrometry data and with the help of literature data, a total of 35 compounds were detected and most of them were flavonoids. Among these compounds, 29 were common components for the two species, two components were unique to Chinese seabuckthorn and 4 were characteristic components of Tibetan seabuckthorn. The results indicated that the compositions of the two kinds of seabuckthorn leaves were quite similar. It is also demonstrated that UPLC/Q-TOF-MS method could be applied to rapidly and effectively analyze and speculate the compounds in leaves of Chinese seabuckthorn and Tibetan seabuckthorn. Copyright© by the Chinese Pharmaceutical Association.
Noser, Jürg; Schneider, Patrick; Rother, Martin; Schmutz, Hansruedi
2011-11-01
An ultra performance liquid chromatography (UPLC)-tandem mass spectrometry (MS/MS) method was developed for the determination of the Alternaria toxins tenuazonic acid, alternariol, alternariol monomethyl ether, altenuene, altertoxin I and tentoxin. Owing to its instability, altenusin could not be determined. The sample preparation includes an acidic acetonitrile/water/methanol extraction, followed by SPE clean-up step, before injection into the UPLC-MS/MS system. The separation was made on an Acquity UPLC column using a water/acetonitrile gradient with ammonium hydrogen carbonate as a modifier. Matrix compounds of real samples led to enhancement as well as suppression of the target compounds, depending on analyte and matrix. The recoveries were between 58 and 109% at a level of 10 μg/kg. Eighty-five tomato products, consisting of peeled and minced tomatoes, soup and sauces, tomato purées and concentrates, ketchup as well as dried and fresh tomatoes, were taken from the Swiss market in 2010. Tenuazonic acid was found most frequently (81 out of 85 samples) and in the highest levels of up to 790 μg/kg. Alternariol and alternariol monomethyl ether were found in lower concentrations, ranging from <1 to 33 μg/kg for alternariol and <5 to 9 μg/kg for alternariol monomethyl ether. Only a few samples were positive for altenuene and tentoxin. Altertoxin I was never detected.
[Rapidly identify oligosaccharides in Morinda officinalis by UPLC-Q-TOF-MSE].
Hao, Qing-Xiu; Kang, Li-Ping; Zhu, Shou-Dong; Yu, Yi; Hu, Ming-Hua; Ma, Fang-Li; Zhou, Jie; Guo, Lan-Ping
2018-03-01
In this paper, an approach was applied for separation and identification of oligosaccharides in Morinda officinalis How by Ultra performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF-MS) with collision energy. The separation was carried out on an ACQUITY UPLC BEH Amide C₁₈(2.1mm×100 mm,1.7 μm) with gradient elution using acetonitrile(A) and water(B) containing 0.1% ammonia as mobile phase at a flow rate of 0.2 mL·min⁻¹. The column temperature was maintained at 40 °C. The information of accurate mass and characteristic fragment ion were acquired by MSE in ESI negative mode in low and high collision energy. The chemical structures and formula of oligosaccharides were obtained and identified by the software of UNIFI and Masslynx 4.1 based on the accurate mass, fragment ions, neutral losses, mass error, reference substance, isotope information, the intensity of fragments, and retention time. A total of 19 inulin oligosaccharide structures were identified including D(+)-sucrose, 1-kestose, nystose, 1F-fructofuranosyl nystose and other inulin oligosaccharides (DP 5-18). This research provided important information about the inulin oligosaccharides in M. officinalis. The results would provide scientific basis for innovative utilization of M. officinalis. Copyright© by the Chinese Pharmaceutical Association.
Qian, Chang-Min; Song, Zhao-Hui; Zhang, Lan-Lan; Zhou, Shui-Ping; Feng, Feng
2013-09-01
An ultra performance liquid chromatography (UPLC) method was established and validated to simultaneously determine the contents of six aconitum alkaloids in mother, daughter and fibrous roots of 19 batches of Aconitum carmichaelii from Sichuan province. The separation of the six alkaloids was achieved on a ACQUITY UPLC BEH C18 (2.1 mm x 100 mm, 1.7 microm) column at 40 degrees C with a mobile phase consisting of acetonitrile in 30 mmol x L(-1) ammonium acetate buffer solution (adjusted to pH 10.0 with aqueous ammonia) in gradient mode. The data and plots showed that the six aconitum alkaloids have different distributions. Four aconitum alkaloids were almost same in mother and daughter root except benzoylmesaconine and mesaconitine, while the fibrous root differed from the other two roots. The comparisons of significant differences of six aconitum alkaloids between the mother and daughter roots definitely demonstrated that benzoylmesaconine and mesaconitine were the representative components. The 38 detecting samples were classified as two clusters by hierarchical clustering analysis (HCA) and principle component analysis (PCA), the results indicated that the mother root was different from the daughter root on chemical material basis. The study might contribute to the reasonable clinical application of A. carmichaelii.
Xiao, Rong; Lin, Yan; Lei, Si-Min; Zhang, Ying; Huang, Jie; Xia, Bo-Hou; Li, Chun; Liao, Duan-Fang; Wu, Ping; Lin, Li-Mei
2017-06-01
To establish a content determination method for 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside (TSG) of the crude/processed root of Polygonum multiflorum from different habitats in China and set up the fingerprint by using UPLC. Various samples were pretreated by macro-porous resin. Then UPLC analysis was performed on Waters ACQUITY UPLC@BEH C18 chromatographic column (2.1 mm×50 mm, 1.7 μm) at (25±5) ℃. A binary gradient elution system was composed of acetonitrile (phase A) and 0.5% acetic acid solution (phase B). Detection was performed at the wavelength of 254 nm, and the mobile flow rate was set at 0.3 mL•min⁻¹. Results showed that the yield of extraction of the 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside from root of P. multiflorum was all over 25.0% after macro-porous resin separation; an exclusive UPLC fingerprint method of the crude/processed root of P. multiflorum from different habitats was successfully set up and 17 chromatographic peaks were calibrated. Cluster analysis can not entirely distinguish the crude one from the processed one, while principal component analysis absolutely can. 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside is the composition that has largest differences in variable importance in projection (VIP) between crude and processed root of P. multiflorum. The separating method can gain high-purity 2,3,5,4'-tetrahydroxy stilbene-2-O-β-D-glucoside, and the determination method is simple, sensitive, reliable and can be used in fast identifying the crude/processed root of P. multiflorum or as a method for overall quality control of root of P. multiflorum. Copyright© by the Chinese Pharmaceutical Association.
Shi, Zhihong; Li, Zhimin; Zhang, Shulan; Fu, Hongna; Zhang, Hongyi
2015-09-01
Based on the phase separation phenomenon of acetonitrile-water system at subzero temperature, a subzero-temperature liquid-liquid extraction coupled with ultra-performance liquid chromatography tandem quadrupole mass spectrometry : UPLC-MS-MS) method was developed for the simultaneous determination of 12 bioactive components in Gegen-Qinlian decoction. After optimization, the extraction conditions were set as follows: 3.0 mL of aqueous sample solution (pH 5.86) was extracted with 2 mL of acetonitrile at -35°C for 35 min. The separated acetonitrile phase was diluted 10-fold with water before UPLC-MS-MS analysis. Separation was performed on a Waters ACQUITY UPLC(®)BEH C18 column (2.1 × 100 mm i.d., 1.7 µm) with ammonium formate buffer solution (20 mmol L(-1), pH 3.2, adjusted by formic acid) and acetonitrile as mobile phase with gradient elution. Twelve target components could be separated within 10 min and quantified in multiple reaction monitoring mode, both positive and negative ionization modes were employed. Limits of detection were in the range of 0.0003-0.0451 μg mL(-1). Relative standard deviation values for intra- and interday precision were <2.71 and 8.94%, respectively. The established method provides a simple and effective framework for the quality control of Gegen-Qinlian decoction and related traditional Chinese medicinal preparations. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
High-speed and high-resolution UPLC separation at zero degrees Celsius
Wales, Thomas E.; Fadgen, Keith E.; Gerhardt, Geoff C.; Engen, John R.
2008-01-01
The conformational properties of proteins can be probed with hydrogen/deuterium exchange mass spectrometry (HXMS). In order to maintain the deuterium label during LC/MS analyses, chromatographic separation must be done rapidly (usually in under 8–10 minutes) and at zero degrees Celsius. Traditional RP-HPLC with ~3 micron particles has shown generally poor chromatographic performance under these conditions and thereby has been prohibitive for HXMS analyses of larger proteins and many protein complexes. Ultra performance liquid chromatography (UPLC) employs particles smaller than 2 microns in diameter to achieve superior resolution, speed, and sensitivity as compared to HPLC. UPLC has previously been shown to be compatible with the fast separation and low temperature requirements of HXMS. Here we present construction and validation of a custom UPLC system for HXMS. The system is based on the Waters nanoACQUITY platform and contains a Peltier-cooled module that houses the injection and switching valves, online pepsin digestion column, and C-18 analytical separation column. Single proteins in excess of 95 kDa and a four-protein mixture in excess of 250 kDa have been used to validate the performance of this new system. Near baseline resolution was achieved in 6 minute separations at 0 °C and displayed a median chromatographic peak width of ~2.7 sec at half height. Deuterium recovery was similar to that obtained using a conventional HPLC and icebath. This new system represents a significant advancement in HXMS technology that is expected to make the technique more accessible and mainstream in the near future. PMID:18672890
Li-Bo, Dai; Miao, Yan; Huan-De, Li; Ping-Fei, Fang; Feng, Wang; Yang, Deng
2013-09-01
A simple and sensitive analytical method based on ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been developed for determination of moclobemide in human brain cell monolayer as an in vitro model of blood-brain barrier. Brucine was employed as the internal standard. Moclobemide and internal standard were extracted from cell supernatant by ethyl acetate after alkalinizing with sodium hydroxide. The UPLC separation was performed on an Acquity UPLC(TM) BEH C18 column (50 × 2.1 mm, 1.7 µm, Waters, USA) with a mobile phase consisting of methanol-water (29.5:70.5, v/v); the water in the mobile phase contained 0.05% ammonium acetate and 0.1% formic acid. Detection of the analytes was achieved using positive ion electrospray via multiple reaction monitoring mode. The mass transitions were m/z 269.16 → 182.01 for moclobemide and m/z 395.24 → 324.15 for brucine. The extraction recovery was 83.0-83.4% and the lower limit of quantitation (LLOQ) was 1.0 ng/mL for moclobemide. The method was validated from LLOQ to 1980 ng/mL with a coefficient of determination greater than 0.999. Intra- and inter-day accuracies of the method at three concentrations ranged from 89.1 to 100.9% for moclobemide with precision of 1.1-9.6%. This validated method was successfully applied to bidirectional transport study of moclobemide blood-brain barrier permeability. Copyright © 2013 John Wiley & Sons, Ltd.
[Content determination of twelve major components in Tibetan medicine Zuozhu Daxi by UPLC].
Qu, Yan; Li, Jin-hua; Zhang, Chen; Li, Chun-xue; Dong, Hong-jiao; Wang, Chang-sheng; Zeng, Rui; Chen, Xiao-hu
2015-05-01
A quantitative analytical method of ultra-high performance liquid chromatography (UPLC) was developed for simultaneously determining twelve components in Tibetan medicine Zuozhu Daxi. SIMPCA 12.0 software was used a principal component analysis PCA) and partial small squares analysis (PLSD-DA) on the twelve components in 10 batches from four pharmaceutical factories. Acquity UPLC BEH C15 column (2.1 mm x 100 mm, 1.7 µm) was adopted at the column temperature of 35 °C and eluted with acetonitrile (A) -0.05% phosphate acid solution (B) as the mobile phase with a flow rate of 0. 3 mL · min(-1). The injection volume was 1 µL. The detection wavelengths were set at 210 nm for alantolactone, isoalantolactone and oleanolic; 260 nm for trychnine and brucine; 288 nm for protopine; 306 nm for protopine, resveratrol and piperine; 370 nm for quercetin and isorhamnetin. The results showed a good separation among index components, with a good linearity relationship (R2 = 0.999 6) within the selected concentration range. The average sample recovery rates ranged between 99.44%-101.8%, with RSD between 0.37%-1.7%, indicating the method is rapid and accurate with a good repeatability and stability. The PCA and PLSD-DA analysis on the sample determination results revealed a great difference among samples from different pharmaceutical factories. The twelve components included in this study contributed significantly to the quantitative determination of intrinsic quality of Zuozhu Daxi. The UPLC established for to the quantitative determination of the twelve components can provide scientific basis for the comprehensive quality evaluation of Zuozhu Daxi.
Yao, Xin; Zhou, Guisheng; Tang, Yuping; Li, Zhenhao; Su, Shulan; Qian, Dawei; Duan, Jin-Ao
2013-03-07
A sensitive and accurate ultra-performance liquid chromatography coupled with triple quadrupole mass (UPLC-MS/MS) method was developed for the determination of quercetin-3-O-β-D-glucopyranoside-(4→1)-α-L-rhamnoside (QGR) in rat plasma using rutin as internal standard. Chromatographic separation was achieved on a Acquity BEH C18 column (100 mm × 2.1 mm, 1.7 μm) with a gradient elution of acetonitrile and 0.10% formic acid (v/v) at a flow rate of 0.4 mL/min. QGR and rutin were detected using electrospray negative ionization mass spectrometry in the multiple reaction monitoring (MRM) mode. The method demonstrated good linearity and did not show any endogenous interference with the QGR and rutin peaks. This method was successfully applied to a pharmacokinetic study of QGR in rats after intravenous (20 mg/kg) and oral (40 mg/kg) administration, and the results showed that the compound was poorly absorbed, with an absolute bioavailability of approximately 3.41%.
Fan, Sai; Zou, Jianhong; Li, Liping; Zhang, Nan; Liu, Wei; Li, Bing; Zhao, Xudong; Wu, Guohua; Xue, Ying; Zhao, Rong
2014-09-01
An ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed to identify and determine 11 industrial antioxidants in the aqueous simulants. A ProElut PLS SPE column was used for the enrichment, and an ACQUITY UPLC BEH C18 UPLC column (100 mm x 2.1 mm, 1.7 μm) was used for separation by the gradient elution with pure water and acetonitrile as the mobile phases. The MS/MS detection was performed with an electrospray ionization (ESI) source in negative mode. The external standard method was used for quantitation in the present study. The linear ranges of the 11 analytes were from 5.0 to 100 μg/L. The coefficients of correlation were greater than 0.995. The recoveries of blank aqueous simulants fortified with the 11 analytes at the levels of 5.0, 10.0 and 20.0 μg/L were 61.4% to 109.4% with the relative standard deviations varied from 3.9% to 18.2% (n = 6). The LODs and LOQs of the 11 analytes in aqueous simulants were 0.2-1.0 μg/L and 0.5-3.0 μg/L, respectively. This method is highly sensitive and accurate, and can be applied to the determination of the 11 trace industrial antioxidants in the aqueous simulants.
Qiu, Xiangjun; Lou, Dan; Su, Ding; Liu, Zebin; Gao, Pengtao; Zhang, Nan-sheng
2015-06-15
An ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated to determine acetaminophen (AAP) and dihydrocodeine (DHC) in human plasma simultaneously. Plasma samples were prepared using protein precipitation with acetonitrile, the two analytes and the internal standard midazolam were separated on an Acquity UPLC BEH C18 column and mass spectrometric analysis was performed using a QTrap5500 mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 151.2→110.0 and m/z 302.3→199.2 were used to quantify for AAP and DHC, respectively. The linearity of this method was found to be within the concentration range of 50-10000ng/mL for AAP, and 1-100ng/mL for DHC in human plasma, respectively. The lower limit of quantification (LLOQ) was 50ng/mL and 1ng/mL for AAP and DHC in human plasma, respectively. The relative standard deviations (RSD) of intra and inter precision were less than 10% for both AAP and DHC. The analysis time of per sample was 1.0min. The developed and validated method was successfully applied to a pharmacokinetic study of AAP (500mg) with DHC (20mg) capsule in Chinese healthy volunteers (N=20). Copyright © 2015 Elsevier B.V. All rights reserved.
Zhang, Ming; Tang, Fangliang; Yu, Yayun; Chen, Feng; Xu, Jianfen; Ye, Yonggen
2014-05-01
A high-throughput detection method has been developed for the determination of sixteen perfluorinated organic compounds (PFCs) in surface water by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The water samples were concentrated and purified through WAX solid phase extraction cartridges. The UPLC separation was performed on an ACQUITY UPLC BEH C18 column utilizing a gradient elution program of methanol (containing 2 mmol/L ammonium acetate) and water (containing 2 mmol/L ammonium acetate) as the mobile phases at a flow rate of 0.4 mL/min. The MS/MS detection was performed under negative electrospray ionization ( ESI ) in multiple reaction monitoring (MRM) mode. Good linearities were observed in the range of 0.5-100 gg/L or 1.0 - 100 microg/L with correlation coefficients from 0.998 7 to 0.999 9. The limits of detection (LODs) for the sixteen perfluorinated organic compounds were in the range of 0.06-0.46 ng/L. The recoveries ranged from 67.6% to 103% with the relative standard deviations between 2.94% and 12.0%. This method was characterized by high sensitivity and precision, extensive range and high speed, and can be applied for the analysis of PFC contaminants in surface water.
Rezk, Mamdouh R; Badr, Kamal A
2018-07-01
A robust, rapid and sensitive UPLC-MS/MS method has been developed, optimized and validated for the determination of amlodipine (AML) and atorvastatin (ATO) in human plasma using eplerenone as an internal standard (IS). Multiple-reaction monitoring in positive electrospray ionization mode was utilized in Xevo TQD LC-MS/MS. Double extraction was used in sample preparation using diethyl ether and ethyl acetate. The prepared samples were analyzed using an Acquity UPLC BEH C 18 (50 × 2.1 mm, 1.7 μm) column. Ammonium formate and acetonitrile, pumped isocraticaly at a flow rate of 0.25 mL/min, were used as a mobile phase. Method validation was done as per the US Food and Drug Administration guidelines. Linearity was achieved in the range of 0.1-10 ng/mL for AML and 0.05-50 ng/mL for ATO. Intra-day and inter-day accuracy and precision were calculated and found to be within the acceptable range. A short run time, of <1.5 min, permits analysis of a large number of plasma samples per batch. The developed and validated method was applied to estimate AML and ATO in a bioequivalence study in healthy human volunteers. Copyright © 2018 John Wiley & Sons, Ltd.
Pandey, Renu; Chandra, Preeti; Srivastava, Mukesh; Mishra, D K; Kumar, Brijesh
2015-01-01
Ocimum sanctum L., with phenolic acids, flavonoids, propenyl phenols and terpenoids as active pharmacological constituents, is a popular medicinal herb and is present as an ingredient in many herbal formulations. Therefore, development of a reliable analytical method for simultaneous determination of the pharmacologically active constituents of O. sanctum is of high importance. To develop and validate a new, rapid, sensitive and selective UPLC-ESI/MS/MS method for simultaneous determination of 23 bioactive markers including phenolic acids, flavonoids, propenyl phenol and terpenoid in the leaf extract and marketed herbal formulations of O. sanctum. An UPLC-ESI/MS/MS method using negative electrospray ionisation (ESI) in multiple-reaction-monitoring (MRM) mode was used for simultaneous determination. Chromatographic separation was achieved on an Acquity UPLC BEH C18 -column using a gradient elution with 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Principal component analysis (PCA) was applied to correlate and discriminate eight geographical collections of O. sanctum based on quantitative data of the analytes. The developed method was validated as per International Conference on Harmonization guidelines and found to be accurate, with overall recovery in the range 95.09-104.84% (RSD ≤ 1.85%), precise (RSD ≤ 1.98%) and linear (r(2) ≥ 0.9971) over the concentration range of 0.5-1000 ng/mL. Ursolic acid was found to be the most abundant marker in all the samples investigated, except for the marketed tablet. The method established is simple, rapid and sensitive, hence it can be reliably utilised for the quality control of O. sanctum and derived herbal formulations. Copyright © 2015 John Wiley & Sons, Ltd.
Zheng, Mengjing; Gu, Shubo; Chen, Jin; Luo, Yongli; Li, Wenqian; Ni, Jun; Li, Yong; Wang, Zhenlin
2017-06-15
A method to determine the lignin monomers (p-hydroxybenzaldehyde, vanillin and syringaldehyde) in plant cell wall of wheat internode was developed and validated using a high-throughput nitrobenzene oxidation step and ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for quantification. UPLC analyses were carried out using an reversed phase C 18 column (ACQUITY UPLC BEH, 1.7μm, 2.1×100mm) and gradient elution with water and acetonitrile. This method was completely validated in terms of analyzing speed, linearity, sensitivity, limits of detection (LODs) and limits of quantification (LOQs).The three lignin monomers were successfully separated within 6min and only 2min were required to regain its equilibrium. The method linearity with regression coefficients values (R2) greater than 0.997. Additionally, LODs ranged from 0.21 to 0.89μgL -1 and LOQs ranged from 0.69 to 2.95μgL -1 . The applicability of this analytical approach for determining the three lignin monomers was confirmed by the successful analysis of real samples of wheat stem internodes. The nitrobenzene oxidation method was used for the analysis of lignin monomers. We have optimized the treatment temperature (170°C, 1h) and realized the high-throughput using the microwave digestion instrument. Recovery of this extraction method ranged from 68.4% to 77.7%. The analysis result showed that the guaiacyl unit (G) was the major component of lignin and there was a higher content of the syringyl unit (S) than that of the hydroxybenzyl unit (H). Copyright © 2017. Published by Elsevier B.V.
Xie, Honglei; Li, Chun; Liu, Ning
2013-08-01
The method for analysing sialic acid in infant formulas by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) has been established. Sialic acid in milk was released via acid hydrolysis, and purified by an HLB solid phase extraction cartridge. The UPLC separation was performed on an ACQUITY UPLC BEH HILIC column (50 mm x 2.1 mm, 1.7 microm) utilizing a gradient elution program of acetonitrile and water (containing 0.1% formic acid) as the mobile phases at a flow rate of 0.25 mL/min. Injection volume and column temperature were set at 5 microL and 30 degrees C, respectively. The identification and quantification were achieved by using electrospray ionisation (ESI)-MS/MS in positive ion mode and multiple reaction monitoring (MRM) mode. The linear range was from 0.05 to 5.0 mg/L for sialic acid and the correlation coefficient (R(2)) was greater than 0.99. The average recoveries spiked at the four concentration levels of 0.1, 0.5, 2.5 and 5.0 mg/L ranged between 84.3% and 98.9% with the relative standard deviations from 4.9% to 8.2%. The limit of detection was 0.01 mg/L. Therefore, this method has the characteristics of simple operation, high reproducibility and sensitivity. It can be widely applied to determine the total contents of sialic acid in infant formula, cow milk and human milk.
Vanol, Pravin G; Singhal, Puran; Shah, Priyanka A; Shah, Jaivik V; Shrivastav, Pranav S; Sanyal, Mallika
2016-08-01
A rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method is described for determination of letrozole in human plasma. Following solid phase extraction (SPE) of letrozole and letrozole-d4 on Orochem DVB-LP cartridges, chromatography was performed on Acquity UPLC BEH C 18 (50 mm×2.1 mm, 1.7 µm) column using methanol-0.1% formic acid in water (85:15, v/v) as the mobile phase. Detection was carried out on a triple quadrupole mass spectrometer with an electrospray source, operated under positive ionization mode. Quantitation of letrozole and letrozole-d4 was done using multiple reaction monitoring (MRM) following the transitions at m/z 286.2→217.0 and m/z 290.2→221.0, respectively. The calibration plots were linear through the concentration range of 0.10-100 ng/mL ( r 2 ≥0.9990) using 100 µL human plasma. The extraction recovery of letrozole ranged from 94.3% to 96.2% and the intra-batch and inter-batch precision was ≤5.2%. The method was successfully applied to a bioequivalence study of letrozole after oral administration of 2.5 mg tablet formulation to 16 healthy postmenopausal Indian women. The assay reproducibility was also established through incurred sample reanalysis (ISR) of 74 subject samples.
NASA Astrophysics Data System (ADS)
Kumar, Nitin; Sangeetha, D.; Kalyanraman, L.
2017-11-01
For determination of process related impurities and degradation products of asenapine maleate in asenapine sublingual Tablets, a reversed phase, stability indicating UPLC method was developed. Acetonitrile, methanol and potassium dihydrogen phosphate buffer with tetra-n- butyl ammonium hydrogen sulphate as ion pair (pH 2.2; 0.01 M) at flow rate of 0.2 ml/min were used in gradient elution mode. Separation was achieved by using acquity BEH Shield RP18 column (1.7 μm, 2.1 mm×100 mm) at 35 ºC. UV detection was performed at 228 nm. Subsequently the liquid chromatography method was validated as per ICH. The drug product was exposed to the stress conditions of acid hydrolysis, base hydrolysis, water hydrolysis, oxidative, thermal, and photolytic. In oxidative stress and thermal stress significant degradation was observed. All the degradation products were well separated from analyte peak and its impurities. Stability indicating nature of the method was proved by demonstrating the peak purity of Asenapine peak in all the stressed samples. The mass balance was found >95% for all the stress conditions. Based on method validation, the method was found specific, linear, accurate, precise, rugged and robust.
Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang
2012-01-25
An ultra-high pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantification of three major ingredients in Chinese lantern preparations (CLP) in rat plasma. Following extraction by ethyl acetate, the analytes were separated on an Acquity UPLC BEH Shield RP C(18) column using a gradient mobile phase system of acetonitrile-water. Electrospray ionization (ESI) tandem interface was employed prior to mass spectrometric detection. The calibration curves were linear over the range of 5.0-500.0 ng/ml for physalin D, 2.3-230.0 ng/ml for physalin G and 0.71-71.0 ng/ml for 4,7-didehydroneophysalin B. The average extraction recoveries, examined at four concentration levels, carried from 57.1% to 76.9%, and the accuracies ranged from 94.0% to 113.3% with precision (RSD) <15%. The validated method was successfully applied to the determination of the three physalins in rat plasma after intragastric administration of CLP suspension. Copyright © 2011 Elsevier B.V. All rights reserved.
Wang, Zhi; Shi, Zongwei; Xi, Cunxian; Wang, Guomin; Cao, Shurui; Zhang, Lei; Tang, Bobin; Mu, Zhaode
2017-12-01
An analytical method was established for the rapid detection of antibiotic growth promoters (AGPs) in bovine muscle, and bovine blood and bovine urine, using ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). After the addition of an aqueous solution of EDTA-Na 2 , the pH of bovine urine samples was directly adjusted to 5.2 by acetic acid-ammonium acetate and purified by HLB solid-phase extraction cartridge; bovine muscle and bovine blood samples processing were extracted with acetonitrile (ACN) and ACNwater (90:10; v/v) without any purification step. The samples were then centrifuged, concentrated and analysed by UPLC-MS/MS on an ACQUITY UPLC® BEH C18 column using gradient elution. The developed method was validated and mean recovery percentages at three spiked levels were 74-119%, 76-115% and 76-119%, respectively, in bovine muscle, bovine blood, and bovine urine. The relative standard deviation (RSD) ranged from 1.0% to 14.7% in spiked bovine muscle, bovine blood and bovine urine. The limits of detection (LOD) of all analytes were in the ranges 0.11-3.82 µg kg -1 , 0.10-2.49 µg kg -1 and 0.06-4.53 µg kg -1 in bovine muscle, bovine blood, and bovine urine, respectively. The method was sensitive, accurate and was applied to monitor real samples. To the best of our knowledge, this is first method available for simultaneous determination of several classes of APGs in bovine muscle, and bovine blood and bovine urine.
2018-01-01
So-Cheong-Ryong-Tang, which is a standardized Korean medicine of the National Health Insurance, is a traditional prescription for the treatment of allergic rhinitis, bronchitis, and bronchial asthma. Simultaneous analysis and development of SCRT is essential for its stability, efficacy, and risk management. In this study, a simple, reliable, and accurate method using ultrahigh-performance liquid chromatography (UPLC) fingerprinting with a diode array detector (DAD) was developed for the simultaneous analysis. The chromatographic separation of the analytes was performed by an ACQUITY UPLC BEH C18 column (1.7 μM, 2.1 × 100 mm, Waters) with a mobile phase of water containing 0.01% (v/v) phosphoric acid and acetonitrile containing 0.01% (v/v) phosphoric acid. The flow rate and detection wavelength were set at 0.4 mL/min and 215, 230, 254, and 280 nm. All calibration curves of the thirteen components showed good linearity (R2 > 0.999). The limit of detection and limit of quantification ranged 0.001–0.360 and 0.004–1.200 µg/mL, respectively. The relative standard deviation (RSD) of intra- and interday was less than 2.60%, and the recoveries were within the range 76.08–103.79% with an RSD value of 0.03–1.50%. The results showed that the developed method was simple, reliable, accurate, sensitive, and precise for the quantification of bioactive components of SCRT. PMID:29854559
Yanamandra, R.; Vadla, C. S.; Puppala, U. M.; Patro, B.; Murthy, Y. L. N.; Parimi, A. R.
2012-01-01
A rapid, simple, sensitive and selective analytical method was developed by using reverse phase ultra performance liquid chromatographic technique for the simultaneous estimation of bambuterol hydrochloride and montelukast sodium in combined tablet dosage form. The developed method is superior in technology to conventional high performance liquid chromatography with respect to speed, resolution, solvent consumption, time, and cost of analysis. Elution time for the separation was 6 min and ultra violet detection was carried out at 210 nm. Efficient separation was achieved on BEH C18 sub-2-μm Acquity UPLC column using 0.025% (v/v) trifluoro acetic acid in water and acetonitrile as organic solvent in a linear gradient program. Resolutions between bambuterol hydrochloride and montelukast sodium were found to be more than 31. The active pharmaceutical ingredient was extracted from tablet dosage from using a mixture of methanol, acetonitrile and water as diluent. The calibration graphs were linear for bambuterol hydrochloride and montelukast sodium in the range of 6.25-37.5 μg/ml. The percentage recoveries for bambuterol hydrochloride and montelukast sodium were found to be in the range of 99.1-100.0% and 98.0-101.6%, respectively. The test solution was found to be stable for 7 days when stored in the refrigerator between 2-8°. Developed UPLC method was validated as per International Conference on Harmonization specifications for method validation. This method can be successfully employed for simultaneous estimation of bambuterol hydrochloride and montelukast sodium in bulk drugs and formulations. PMID:23325991
Jamalapuram, Seshulatha; Vuppala, Pradeep Kumar; Abdelazeem, Ahmed H; McCurdy, Christopher R; Avery, Bonnie A
2013-08-01
Methamphetamine abuse continues as a major problem in the USA owing to its powerful psychological addictive properties. AZ66, 3-[4-(4-cyclohexylpiperazine-1-yl)pentyl]-6-fluorobenzo[d]thiazole-2(3H)-one, an optimized sigma receptor ligand, is a promising therapeutic agent against methamphetamine. To study the in vivo pharmacokinetics of this novel sigma receptor ligand in rats, a sensitive ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method was developed in rat plasma and validated. The developed method requires a small volume of plasma (100 μL) and a simple liquid-liquid extraction. The chromatographic separations were achieved in 3.3 min using an Acquity UPLC BEH Shield RP18 column. The mass spectrophotometric detection was carried out using a Waters Micromass Quattro MicroTM triple-quadrupole system. Multiple reaction monitoring was used for the quantitation with transitions m/z 406 → m/z 181 for AZ66 and m/z 448 → m/z 285 for aripiprazole. The method was validated over a concentration range of 1-3500 ng/mL and the lower limit of quantitation was determined to be 1 ng/mL. Validation of the assay demonstrated that the developed UPLC/MS/MS method was sensitive, accurate and selective for the determination of AZ66 in rat plasma. The present method has been successfully applied to an i.v. pharmacokinetic study in Sprague-Dawley rats. Copyright © 2013 John Wiley & Sons, Ltd.
Bihan, Kevin; Lu, Qin; Enjalbert, Manon; Apparuit, Maxime; Langeron, Olivier; Rouby, Jean-Jacques; Funck-Brentano, Christian; Zahr, Noël
2016-12-01
Colistin is a polypeptide antibiotic from the polymyxin E group used for the treatment of infections caused by multidrug-resistant gram-negative bacteria. The main constituents, accounting for approximately 85% of this mixture, are colistin A (polymyxin E1) and colistin B (polymyxin E2). The aim of this study was to develop and validate new and fast methods of quantification of colistin A and B and its precursors [colistin methanesulfonate sodium (CMS) A and B] by ultraperformance liquid chromatography-tandem mass spectrometry in plasma and urine with short pretreatment and run times. Chromatography was performed on an Acquity UPLC-MS/MS system (WATERS) with a WATERS Acquity UPLC C18 column (4.6 × 150 mm, 3.5 μm particle size). The pretreatment of samples consists of precipitation and extraction into microcolumns plate and HLB 96-well plate 30 μm-30 mg (OASIS) with a Positive Pressure-96 (WATERS). Quantification was performed using a multiple reaction monitoring of the following transitions: m/z 390.9 → 385.1 for colistin A, m/z 386.2 → 101.0 for colistin B, and m/z 602.4 → 241.1 for polymyxin B1 sulfate. In plasma and urine, calibration curves were linear from 30 to 6000 ng/mL for colistin A and from 15 to 3000 ng/mL for colistin B. With an acceptable accuracy and precision, the lower limit of quantification were set at 24.0 ng/mL and 12.0 ng/mL for colistin A and B in plasma, and at 18.0 ng/mL and 9.0 ng/mL for colistin A and B in urine. These LC-MS/MS methods of quantification for colistin A and B and its precursors (CMS A and B) in plasma and urine are fast, simple, specific, sensitive, accurate, precise, and reliable. Furthermore, they are linear and repeatable. These procedures were successfully applied to a pharmacokinetic study of a critically ill patient suffering from ventilator-associated pneumonia, who was treated with nebulized CMS.
Yin, Gang; Cheng, Xiaolan; Tao, Weiwei; Dong, Yu; Bian, Yong; Zang, Wenhua; Tang, Decai
2018-01-30
The herb-pair, Astragali Radix (AR) and Curcumae Rhizoma (CR), often occurs in traditional herbal prescriptions used for cancer treatment in Asian areas. In clinical application, the AR-CR herb pair was often produced by different preparation methods or with raw materials from different sources, which raised a challenge for quality control of the herb-pair medicines. In this paper, ultra high performance liquid chromatography coupled to triple quadrupole tandem mass spectrometry method (UPLC-QQQ-MS) was applied for the first time to simultaneously determine 17 main bioactive components for quality control of AR-CR herb pair. The chromatographic separation was studied on an ACQUITY UPLC BEH C 18 column (100mm×2.1mm, 1.7μm) with a mobile phase composed of 0.1% aqueous formic acid and acetonitrile using a gradient elution in 12min. The proposed method was optimized and validated by good linearity (r 2 >0.9970), limit of detection (0.33-10.78ng/mL), limit of quantification (0.81-2.54ng/mL), intra- and inter-day precisions (RSD≤3.64%, RSD≤5.68%), stability (RSD≤4.29%), repeatability (RSD≤5.98%), recovery (90.20-107.60%). The established method was successfully applied to comparative analysis of main bioactive components in AR-CR herb pair and its single herbs, and quality evaluation of different batches of clinical dispensing granules. Compared to the single herb, the content of most liposoluble constituents such as curcumenol, curdione, isocurcumenol, furanodienone, curcumol, and germacrone were remarkable increased in their herb pair, suggesting mixed preparation produced synergistic effects on promoting the extraction of bioactive ingredients. This study is the first time to report the rapid and simultaneous analysis of 17 compounds in AR-CR herb pair by UPLC-QQQ-MS, and provides a feasible method for holistic quality control of preparations containing AR-CR herb-pair. Copyright © 2017 Elsevier B.V. All rights reserved.
Xu, Pan; Du, Shou-Ying; Lu, Yang; Bai, Jie; Liu, Hui-Min; Du, Qiu; Chen, Zhen-Zhen; Wang, Zhen
2014-06-01
To establish a UPLC-MS/MS method for the simultaneous determination of geniposide, genipin 1-O-beta-D-gentiobioside and geniposidic acid in rat brains and study the brain pharmacokinetics of the three iridoid glycosides in stroke rat after the oral administration of Xingnaojing. In this experiment, brain samples were precipitated with protein for twice. Acquity BEH C18 column was adopted, with acetonitrile-0.1% formic acid-water as the mobile phase for gradient elution. ESI source was adopted for mass spectra; multiple reaction monitoring (MRM) was conducted to detect negative ions. The time for sample analysis was 3.5 min. the results showed good linear relations among the three iridoid glycosides, with the extraction recovery between 99.6% and 114.3%, good intra- and inter-day precisions and accuracies and stability in line with the requirements. The t1/2 and MRT in the three components were similar in brains of stroke rats. Geniposide and genipin 1-O-beta-D-gentiobioside showed double peaks; where as geniposidic acid showed a single peak. In conclusion, the method is so specific, sensitive, accurate and reliable that it can be used to study the brain pharmacokinetics of Xingnaojing oral preparation.
Wang, Yanjuan; Wen, Jing; Zheng, Weihua; Zhao, Longshan; Fu, Xiaohuan; Wang, Zhenzhong; Xiong, Zhili; Li, Famei; Xiao, Wei
2015-01-01
A simple, specific and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was established and validated for simultaneous determination of neochlorogenic acid, chlorogenic acid, cryptochlorogenic acid and geniposide in rat plasma using puerarin as an internal standard (IS). Plasma samples were pretreated by a one-step direct protein precipitation procedure with acetonitrile after acidified using as little as 50 μL plasma. Chromatographic separation was performed on an Acquity BEH C18 column (100 × 2.1 mm, 1.7 µm) at a flow rate of 0.2 mL/min by a gradient elution, using 0.2% acetic acid-methanol as mobile phase. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring via electrospray ionization source with negative ion mode. Calibration curves showed good linearity (r > 0.995) over wide concentration ranges. The intra- and inter-day precisions were <15%, and the accuracy was within ±8.0%. The validated method was successfully applied to a pharmacokinetic study of the four bioactive components in rats after intravenous administration of Reduning injection. Copyright © 2014 John Wiley & Sons, Ltd.
Liang, Jun; Sun, Hui-Min; Wang, Tian-Long
2017-11-24
The Shuang-Huang-Lian (SHL) oral liquid is a combined herbal prescription used in the treatment of acute upper respiratory tract infection, acute bronchitis and pneumonia. Multiple constituents are considered to be responsible for the therapeutic effects of SHL. However, the quantitation of the multi-components from multiple classes is still unsatisfactory because of the high complexity of constituents in SHL. In this study, an accurate, rapid, and specific UPLC-MS/MS method was established for simultaneous quantification of 18 compounds from multiple classes in SHL oral liquid formulations. Chromatographic separation was performed on a HSS T3 (1.8 μm, 2.1 mm × 100 mm) column, using a gradient mobile phase system of 0.1% formic acid in acetonitrile and 0.1% formic acid in water at a flow rate of 0.2 mL·min -1 ; the run time was 23 min. The MS was operated in negative electrospray ionization (ESI - ) for analysis of 18 compounds using multiple reaction monitoring (MRM) mode. UPLC-ESI - -MRM-MS/MS method showed good linear relationships ( R ² > 0.999), repeatability (RSD < 3%), precisions (RSD < 3%) and recovery (84.03-101.62%). The validated method was successfully used to determine multiple classes of hydrophilic and lipophilic components in the SHL oral liquids. Finally, principal component analysis (PCA) was used to classify and differentiate SHL oral liquid samples attributed to different manufacturers of China. The proposed UPLC-ESI - -MRM-MS/MS coupled with PCA has been elucidated to be a simple and reliable method for quality evaluation of SHL oral liquids.
Tylová, Tereza; Kolařík, Miroslav; Olšovská, Jana
2011-07-01
A new simple ultra-high-performance liquid chromatography method with diode array detection (UHPLC-DAD) was developed for chemical fingerprinting analysis of extracellular metabolites in fermentation broth of Geosmithia spp. The SPE method employing Oasis MCX strong cation-exchange mixed-mode polymeric sorbent was chosen for extraction of the metabolites. The analyses were performed on an Acquity UPLC BEH C18 column (100 × 2.1 mm i.d.; particle size, 1.7 μm; Waters) using a gradient elution program with an aqueous solution of trifluoroacetic acid and acetonitrile as the mobile phase. The applicability of the method was proved by analysis of 38 strains produced by different species and isolated from different sources (hosts). The results revealed the correlation of obtained UHPLC-DAD fingerprints with taxonomical identity.
Krishnaiah, Ch; Vishnu Murthy, M; Kumar, Ramesh; Mukkanti, K
2011-03-25
A simple, sensitive and reproducible ultra performance liquid chromatography (UPLC) coupled with a photodiode array detector method was developed for the quantitative determination of olanzapine (OLN) in API and pharmaceutical dosage forms. The method is applicable to the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH 100-mm, 2.1-mm, and 1.7-μm C-18 columns, and the gradient eluted within a short runtime, i.e., within 10.0 min. The eluted compounds were monitored at 250 nm, the flow rate was 0.3 mL/min, and the column oven temperature was maintained at 27°C. The resolution of OLN and eight (potential, bi-products and degradation) impurities was greater than 2.0 for all pairs of components. The high correlation coefficient (r(2)>0.9991) values indicated clear correlations between the investigated compound concentrations and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the RSD, were less than 2.4%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method expressed as relative error was satisfactory. No interference was observed from concomitant substances normally added to the tablets. The drug was subjected to the International Conference on Harmonization (ICH)-prescribed hydrolytic, oxidative, photolytic and thermal stress conditions. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness and robustness. Copyright © 2010 Elsevier B.V. All rights reserved.
Li, Guofei; Cai, Cuifang; Ren, Tianyang; Tang, Xing
2014-01-01
With the purpose to carry out the pharmacokinetic studies of 10-hydroxy camptothecin (10-HCPT) and hydroxyethyl starch (10-HCPT-HES) conjugate, an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated. The analytes, 10-HCPT and the internal standard, Diphenhydramine hydrochloride were extracted with ethyl acetate-isopropanol (95:5, v/v) and separated on an ACQUITY UPLC™ BEH C18 column using a mobile phase composed of acetonitrile and water (containing 0.1% formic acid) with a linear gradient program. With positive ion electrospray ionization (ESI), the analytes were monitored on a triple quadrupole mass spectrometer in the multiple reaction monitoring (MRM) mode. Linear calibration curves were obtained over the concentration ranges of 0.5-2500ng/mL. The intra- and inter-day precisions were less than 9.8% and 10.8%, respectively. The accuracy was within 12.1%. The mean recoveries of 10-HCPT at three concentrations of 2.5, 100, 2000ng/mL were higher than 87.2%. Commercial 10-HCPT injection and 10-HCPT-HES conjugate were administered intravenously at an equal dose of 10-HCPT at 0.5mg/kg. The biological half-life of conjugate was increased significantly from 10min to 3.15h and the bioavailability was 40 times higher than 10-HCPT injection. Consequently, the proposed UPLC-ESI-MS/MS method was proved to be sensitive, specific and reliable to analyze 10-HCPT in biological samples; 10-HCPT and HES conjugate is a promising strategy for delivery of 10-HCPT with prolonged half time and improved bioavailability. Copyright © 2013 Elsevier B.V. All rights reserved.
Zheng, Yunliang; Chen, Yong; Ren, Yiping; Luan, Lianjun; Wu, Yongjiang
2012-01-01
Chinese lantern is the calyx or calyx-with-fruit of the plant Physalis alkekengi .var. franchetii (Solanaceae), and is potential material for the food and pharmaceutical industries. Physalins are the most active and representative secondary metabolites of Chinese lantern. A separation and quantification method based on UPLC-ESI-MS/MS was developed for the quantitative analysis of five active physalins. The transformation products were also detected and identified for the first time. To establish a LC-MS/MS method to quantify five physalins in Chinese lantern for the purpose of quality control, and to identify the transformation products of 4,7-didehydrophysalin B. The separation was carried out on an Acquity UPLC BEH Shield RP C₁₈-column with water and acetonitrile as the mobile phase under gradient conditions. ESI-MS/MS was used as the detector to quantify the five physalins. The transformation products of 4,7-didehydroneophysalin B were detected by UPLC-PDA-ESI-MS/MS and identified through comparing their HRMS and MS² ion fragmentations with corresponding references. All the compounds showed good linearity (R² > 0.998). The recoveries, measured at three concentration levels, varied from 98.8 to 101.4% with RSDs < 4.5%. The total contents of the five physalins in Chinese lantern varied significantly. Three transformation products of 4,7-didehydroneophysalin B were detected and tentatively identified. The present study developed a highly effective analytical method for the quality control of Chinese lantern, and it could provide comprehensive information for quality evaluation and new drug development of Chinese lantern. Copyright © 2011 John Wiley & Sons, Ltd.
Badawi, Nora; Simonsen, Kirsten Wiese; Steentoft, Anni; Bernhoft, Inger Marie; Linnet, Kristian
2009-11-01
The European DRUID (Driving under the Influence of Drugs, Alcohol And Medicines) project calls for analysis of oral fluid (OF) samples, collected randomly and anonymously at the roadside from drivers in Denmark throughout 2008-2009. To analyze these samples we developed an ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and Delta-9-tetrahydrocannabinol. Solid-phase extraction was performed with a Gilson ASPEC XL4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole (positive electrospray ionization mode, multiple reaction monitoring mode). Extraction recoveries were 36%-114% for all analytes, including Delta-9-tetrahydrocannabinol and benzoylecgonine. The lower limit of quantification was 0.5 mug/kg for all analytes. Total imprecision (CV) was 5.9%-19.4%. With the use of deuterated internal standards for most compounds, the performance of the method was not influenced by matrix effects. A preliminary account of OF samples collected at the roadside showed the presence of amphetamine, cocaine, codeine, Delta-9-tetrahydrocannabinol, tramadol, and zopiclone. The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including Delta-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult to incorporate into multicomponent methods.
[Quality control of Guci tablets using UPLC-ELSD fingerprint analysis coupled with chemometrics].
Wang, Ya-Dan; Dai, Zhong; Sun, Cai-Lin; Wu, Xian-Fu; Ma, Shuang-Cheng
2018-03-01
Ultra-performance liquid chromatography-evaporative light scattering detection (UPLC-ELSD) fingerprint analysis method was established for quality control of Guci tablets. Chromatographic separation was performed on Waters Acquity UPLC BEH C₁₈ column (2.1 mm×100 mm, 1.7 μm) at 30 °C of column temperature. Acetonitrile-0.1% formic acid solution was adopted as mobile phase for gradient elution. The flow rate was set at 0.3 mL·min⁻¹, and the injection volume was 3 μL. Detection was carried out on an ELSD with a nitrogen pressure of 0.28 MPa, drift tube temperature of 60 °C, and gain of 400. A total of 39 batches of samples produced by six manufacturers were measured by using the above method and the data were analyzed by ChemPattern software. The peak present in more than 75% of the samples was defined as a common peak, and 30 common peaks were determined. Among them, 19 peaks were identified by rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) method, 16 of which were confirmed by reference substances. The similarity of the tested samples was 0.47-0.98, suggesting that the quality of the samples from different manufacturers varied greatly. Furthermore, principal component analysis (PCA) and hierarchical analysis (HCA) were performed to clarify the main different components in samples. The results indicated that there might be some feeding problems about Paeoniae Radix Alba, Notoginseng Radix et Rhizoma, and Clematidis Radix et Rhizoma in a few manufacturers. This study provided some evidences for the overall quality control of Guci tablets, as well as its quality standard improvements. Copyright© by the Chinese Pharmaceutical Association.
Wang, Jiang; Pavurala, Naresh; Xu, Xiaoming; Krishnaiah, Yellela S R; Faustino, Patrick J
2018-05-04
To evaluate the bioavailability and pharmacokinetic profiles of two novel galantamine formulations as medical countermeasure products, an ultra-performance liquid chromatography-single quadrupole mass spectrometry (UPLC-MS) method was developed and validated for quantifying galantamine in guinea pig plasma using solid-phase extraction with a mixed mode strong cation exchange reversed-phase cartridge. Chromatographic separation was achieved on a Waters Acquity UPLC BEH C 18 column maintained at 40°C. The mobile phases were solution A, acetonitrile-water, 5:95 (v/v) and solution B, acetonitrile-water 90:10 (v/v), both containing 2 mM ammonium formate and 0.2% formic acid. The mobile phase was delivered utilizing a 3 min gradient program start with 95%A-5%B at a flow rate of 0.6 mL/min. The analyte and internal standard, galantamine-d3, were detected by selected ion monitoring mode on a Waters 3100 single quadrupole mass spectrometer with positive electrospray ionization. The method was validated according to the US Food and Drug Administration bioanalytical guidance. The method was selective and was linear over the analytical range of 2-2000 ng/mL. Accuracy and precision were acceptable with intra- and inter-day accuracies between 96.8 and 101% and precisions (RSD) <4.88%. The method was successfully implemented to measure galantamine plasma levels in a series of pre-clinical bioavailability studies for the evaluation of novel galantamine formulations. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
de Loor, Henriette; Poesen, Ruben; De Leger, Wout; Dehaen, Wim; Augustijns, Patrick; Evenepoel, Pieter; Meijers, Björn
2016-09-14
Chronic kidney disease (CKD) is associated with an increased risk of mortality and cardiovascular disease, which is, at least partly, mediated by the accumulation of so-called uremic retention solutes. Although there has been an increasing interest in the behavior of these solutes, derived from both the endogenous and colonic microbial metabolism, methods to simultaneously and accurately measure a broad panel of relevant uremic retention solutes remain scarce. We developed a highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. A high throughput sample preparation was used with extraction of analytes from 50 μl serum using Ostro plate technology. For most solutes, stable isotopes labelled metabolites were used as internal standards. Chromatography was achieved using an Acquity UPLC CSH Fluoro Phenyl column. The total run time was 8 min, the mobile phase was a gradient of 0.1% formic acid in Milli-Q water and pure methanol at a flow rate of 0.5 ml min(-1). Detection was performed using a tandem mass spectrometer with alternated positive and negative electrospray ionization. Calibration curves were linear for all solutes. Precision was assessed according to the NCCLS EP5-T guideline, being below 15% for all metabolites. Mean recoveries were between 83 and 104% for all metabolites. The validated method was successfully applied in a cohort of 488 patients with CKD. We developed and validated a sensitive and robust UPLC-MS/MS method for quantification of 15 uremic retention solutes derived from endogenous and colonic microbial metabolism. This method allows for studying the behavior and relevance of these solutes in patients with CKD. Copyright © 2016 Elsevier B.V. All rights reserved.
Stragierowicz, Joanna; Daragó, Adam; Brzeźnicki, Sławomir; Kilanowicz, Anna
2017-07-26
Glutamate (Glu) and γ-aminobutyric acid (GABA) are the main neurotransmitters in the central nervous system for excitatory and inhibitory processes, respectively. Monitoring these neurotransmitters is an essential tool in establishing pathological functions, among others in terms of occupational exposure to toxic substances. We present modification of the HPLC (high-performance liquid chromatography) to the UPLC (ultra-performance liquid chromatography) method for the simultaneous determination of glutamate and γ-aminobutyric acid in a single injection. The isocratic separation of these neurotransmitter derivatives was performed on Waters Acquity BEH (ethylene bridged hybrid) C18 column with particle size of 1.7 μm at 35°C using a mobile phase consisting of 0.1 M acetate buffer (pH 6.0) and methanol (60:40, v/v) at a flow rate of 0.3 ml/min. The analytes were detected with the fluorescence detector (FLD) using derivatization with o-phthaldialdehyde (OPA), resulting in excitation at 340 nm and emission at 455 nm. Several validation parameters including linearity (0.999), accuracy (101.1%), intra-day precision (1.52-1.84%), inter-day precision (2.47-3.12%), limit of detection (5-30 ng/ml) and quantification (100 ng/ml) were examined. The developed method was also used for the determination of these neurotransmitters in homogenates of selected rat brain structures. The presented UPLC-FLD is characterized by shorter separation time (3.5 min), which is an adaptation of the similar HPLC methods and is an alternative for more expensive references techniques such as liquid chromatography coupled with tandem mass-spectrometry (LC-MS/MS) methods. Med Pr 2017;68(5):583-591. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.
Chen, Wei-Ying; Zhou, Xian-Zhen; Wu, Li-Lan; Wu, Yun-Shan; Wang, Shu-Mei; Liu, Bo; Guo, De-An
2017-07-01
Caesalpinia sappan L. is a traditional medicinal plant which is used for promoting blood circulation and cerebral apoplexy therapy in China. Previous reports showed that the extracts of Caesalpinia sappan L. could exert vasorelaxant activity and anti-inflammation activity. Protosappanin B is a major constituent of C. sappan L., and showed several important bioactivities. The separation was achieved by an Acquity UPLC BEH Symmetry Shield RP 18 column (1.7 μm, 2.1 × 100 mm) column with the gradient mobile phase consisting of 5 mm ammonium acetate aqueous solution and acetonitrile. Detection was carried out by using negative-ion electrospray tandem mass spectrometry via multiple reaction monitoring. Plasma samples were preprocessed by an extraction with ethyl acetate, and apigenin was used as internal standard. The current UPLC-MS/MS assay was validated for linearity, accuracy, intraday and interday precisions, stability, matrix effects and extraction recovery. After oral and intravenous administration, the main pharmacokinetic parameters were as follows: peak concentrations, 83.5 ± 46.2 and 1329.6 ± 343.6 ng/mL; areas under the concentration-time curve, 161.9 ± 69.7 and 264.9 ± 56.3 μg h/L; and half-lives, 3.4 ± 0.9 and 0.3 ± 0.1 h, respectively. The absolute bioavailability in rats of protosappanin B was 12.2%. The method has been successfully applied to a pharmacokinetic and bioavailability study of protosappanin B in rats. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Wabaidur, Saikh Mohammad; Alothman, Zeid Abdullah; Khan, Mohammad Rizwan
2013-05-01
In present study, a rapid and sensitive method using ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet. The optimum chromatographic separation was carried out on a reversed phase Waters® Acquity UPLC BEH C18 column (1.7 μm particle size, 100 mm × 2.1 mm ID) with an isocratic elution profile and mobile phase consisting of 0.1% formic acid in water and acetonitrile (75:25, v/v, pH 3.5) at flow rate of 0.5 mL min-1. The influences of mobile phase composition, flow rate and pH on chromatographic resolution were investigated. The total chromatographic analysis time was as short as 2 min with excellent resolution. Detection and quantification of the target compounds were carried out with a triple quadrupole mass spectrometer using negative electrospray ionization (ESI) and multiple reaction monitoring (MRM) modes. The performance of the method was evaluated and very low limits of detection less than 0.09 μg g-1, excellent coefficient correlation (r2 > 0.999) with liner range over a concentration range of 0.1-1.0 μg g-1 for both L-ascorbic acid and acetylsalicylic acid, and good intraday and interday precisions (relative standard deviations (R.S.D.) <3%), were obtained. Comparison of system performance with traditional liquid chromatography-photo diode array detector (HPLC-PDA) was made with respect to analysis time, sensitivity, linearity and precisions. The proposed UPLC-MS/MS method was found to be reproducible and appropriate for quantitative analysis of L-ascorbic acid and acetylsalicylic acid in aspirin C effervescent tablet.
Prokopenko, Yuliya; Jakštas, Valdas; Žvikas, Vaidotas; Georgiyants, Victoriya; Ivanauskas, Liudas
2018-05-18
The aim of research was to study the content of amino acids using in extracts of Fumaria schleicheri L., Ocimum basilicum L., and Corylus avellana L. by HILIC MS/MS method. Separation of amino acids in the samples was carried out with Acquity H-class UPLC system (Waters, Milford, USA) equipped with SeQuant ZIC-Hilic collumn (2.1 × 150 mm, 3.5 μm) (Merck Millipore, Darmstadt, Germany). The MS/MS fragment ion chromatograms of the test solutions established the presence of 19 amino acids. The obtained results have shown that O. basilicum L. characterized the highest concentrations of different neurogenic amino acids (128.1 mg/kg), comparing with F. schleicheri L. and C. avellana L. (57.72 and 52.91 mg/kg, respectively).
Chen, Mengchun; Zhang, Xiaoqian; Wang, Hao; Lin, Baoli; Wang, Shuanghu; Hu, Guoxin
2015-04-01
A sensitive and rapid ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS-MS) method for the determination of rutin in rat plasma was developed and validated. After addition of tolbutamide as internal standard (IS), protein precipitation by acetonitrile was used as sample preparation. The chromatographic separation was performed on an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7 μm particle size), using acetonitrile-0.1% formic acid as the mobile phase with gradient elution, delivered at a flow-rate of 0.4 mL/min. Mass spectrometric analysis was performed using a XEVO TQD mass spectrometer coupled with an electro-spray ionization (ESI) source in the positive ion mode. The MRM transitions of m/z 610.91→302.98 and m/z 271.2→155.1 were used to quantify for rutin and tolbutamide, respectively. This assay method has been fully validated in terms of specificity, linearity, recovery and matrix effect, accuracy, precision and stability. Calibration curves were linear in the concentration ranges of 25-2000 ng/mL for rutin. Only 3 min was needed for an analytical run. This developed method was successfully used for determination of rutin in rat plasma for pharmacokinetic study. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Zhou, Ying; Liu, Ming; Jiang, Ji; Wang, Hongyun; Hu, Pei
2013-11-15
A sensitive and rapid method based on ultra-performance liquid chromatography coupled with tandem mass spectrometry (UPLC-MS/MS) was developed and validated for the simultaneous determination of blonanserin, its major active metabolite (N-deethyl form) and other three metabolites (N-oxide form, Ethylenediamine form and Carboxylate form) in human plasma. Plasma samples were pre-purified by solid-phase extraction (SPE) and analyzed using a gradient chromatographic separation over an Acquity UPLC CSH C18 column. The mobile phase consisted of acetonitrile-water containing 5mM ammonium formate and 0.1% formic acid at a flow rate of 0.5mL/min. Positive electrospray ionization was employed as the ionization source in the multiple reaction monitoring (MRM) mode. The analysis time was about 3.5min. The method was fully validated over the concentration range of 0.01-1ng/mL for all analytes. The lower limit of quantification (LLOQ) was 0.01ng/mL. Inter- and intra-batch precision was less than 15% and the accuracy was within 85-115%. The mean extraction recoveries of all analytes at two concentration levels were consistent. Selectivity, matrix effect and stability were also validated. The method was applied to the pharmacokinetic study of blonanserin in Chinese healthy subjects. Copyright © 2013 Elsevier B.V. All rights reserved.
Zhou, Yao; Yang, Huiqin; Shi, Yiyin; Chen, Jiaxian; Zhu, Jian; Deng, Xiaojun; Guo, Dehua
2017-09-08
A method was developed for the simultaneous determination of six strobilurin fungicide ( E -metominostrobin, azoxystrobin, kresoxim-methyl, picoxystrobin, pyraclostrobin and trifloxystrobin) residues in orange, banana, apple and pineapple samples by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). The fragmentation routes of all the compounds were explained by the aid of a fragment predicting software ACD Lab/MS Fragmenter. The samples were extracted by acetonitrile, then cleaned up by amino solid phase extraction cartridges (SupelClean LC-NH 2 ). The extracts were separated on a ACQUITY UPLC BEH C 18 column (50 mm×2.1 mm, 1.7 μm) with gradient elution. Acetonitrile containing 0.1% (v/v) formic acid and 10 mmol/L ammonium acetate containing 0.1% (v/v) formic acid were used as mobile phases. The samples were detected by electrospray ionization (ESI)-MS/MS in positive ion and multiple reaction monitoring (MRM) mode, quantified by external standard method. Good linearities were obtained in the range of 5-100 μg/L (for pyraclostrobin, 1-20 μg/L) with correlation coefficients ( r 2 ) greater than 0.999. The recoveries ranged from 60.4% to 120% with the relative standard deviations between 2.15% and 15.1% ( n =6). The developed method can meet the inspection of the six strobilurin residues in the orange, banana, apple and pineapple samples.
Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui
2014-05-01
A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were < or = 10 microg/kg, which can meet the requirements for the actual screening of cosmetic samples. The developed method was applied to screen the hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.
Huang, Xiaochen; Su, Shulan; Cui, Wenxia; Liu, Pei; Duan, Jin-ao; Guo, Jianming; Li, Zhenhao; Shang, Erxin; Qian, Dawei; Huang, Zhijun
2014-07-01
In this present study, a sensitive and rapid UPLC-MS/MS method was developed for simultaneous quantification of paeoniflorin, albiflorin, ferulic acid, tetrahydropalmatine, protopine, typhaneoside and senkyunolide I in Beagle dog plasma after oral administration of the Shao-Fu-Zhu-Yu Decoction. Chloramphenicol and clarithromycin were used as internal standards. Plasma samples were processed by protein precipitation with methanol. The separation was performed on an Acquity BEH C18 column (100mm×2.1mm, 1.7μm) at a flow-rate of 0.4mL/min, using 0.1% formic acid-acetonitrile as mobile phase. Method validation was performed as per Food and Drug Administration guidelines and the results met the acceptance criteria. After validation, this method was successfully applied to a pharmacokinetic study. The results showed that the apparent plasma clearance of paeoniflorin, albiflorin, typhaneoside and senkyunolide I were significantly higher than others. Double peak was observed in plasma concentration curves of tetrahydropalmatine, the ferulic acid had a good absorption in Beagle dog plasma, and senkyunolide I was detected in plasma from the first blood sampling time (15min) and rapidly reached Tmax. The compound of typhaneoside has a low bioavailability according to the results. Copyright © 2014. Published by Elsevier B.V.
Shan, Xiao Mei; Shen, Deng Hui; Wang, Bing Shuang; Lu, Bei Bei; Huang, Fa Yuan
2014-06-01
To establish an analytical method for determination of four bisphenols (BPA, BPB, BPF, and BPS) and two alkylphenols (4-n-OP, 4-n-NP) in water by ultra performance liquid chromatography- tandem mass spectrometry (UPLC/MS/MS). The water samples were extracted and condensed with solid-phase extraction (SPE) using C18 cartridges and eluted by acetonitrile. Separation was carried out with Acquity BEH C8 column and detection were performed by UPLC/MS/MS. Quantification was calculated by using the internal standard BPA-d16 and 4-n-NP-d8. The linear correlation coefficients of these compounds in the range of 1.0-100.0 μg/L were all over 0.999. The minimum detectable concentrations were 0.75-1.0 ng/L, and the recoveries ranged from 87.0% to 106.9%. Relative standard deviations (RSDs) were between 1.26% and 3.67%. Applying this method to detect the source water of Chaohu Lake and drinking water of Hefei, six target compounds were detected in different levels. This method is simple with high sensitivity and selectivity, could be suitable for the determination of these compounds in source and drinking water. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
El-Bagary, Ramzia; Hashem, Hanaa; Fouad, Marwa; Tarek, Sally
2016-09-01
A sensitive, rapid and simple liquid chromatographic-electrospray ionization tandem mass spectrometric (LC-ESI-MS-MS) method was developed for the quantitative determination of vilazodone in human plasma and for the study of the pharmacokinetic behavior of vilazodone in healthy Egyptian volunteers. With escitalopram as internal standard (IS), liquid-liquid extraction was used for the purification and preconcentration of analytes from human plasma matrix using diethyl ether. The separation was performed on an Acquity UPLC BEH shield RP C18 column (1.7 µm, 2.1 × 150 mm). Isocratic elution was applied using methanol-0.2% formic acid (90:10, v/v). Detection was performed on a triple-quadrupole tandem mass spectrometer with multiple reaction monitoring mode via an electrospray ionization source at m/z 442.21 → 155.23 for vilazodone and m/z 325.14 → 109.2 for escitalopram. Linear calibration curves were obtained over the range of 1-200 ng/mL with the lower limit of quantification at 1 ng/mL. The intra- and inter-day precision showed relative standard deviation ≤3.3%. The total run time was 1.5 min. This method was successfully applied for clinical pharmacokinetic investigation, and a preliminary metabolic study was also carried out. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li, Zhe; Xing, Yuping; Guo, Xingjie; Cui, Yan
2017-07-15
There are significant differences in d-amino acid concentrations between healthy people and Alzheimer's disease patients. In order to investigate the potential correlation between d-amino acids and Alzheimer's disease, a simple and sensitive ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed. The method was applied to simultaneous determination of 11 d-amino acids in different regions of rat brain. Rat brain homogenates were firstly pretreated with protein precipitation procedure and then derivatized with (S)-N-(4-nitrophenoxycarbonyl) phenylalanine methoxyethyl ester [(S)-NIFE]. Baseline separation of the derivatives was achieved on an ACQUITY UPLC BEH C 18 column (2.1 mm×50mm, 1.7μm). The mobile phase consisted of acetonitrile and water (containing 8mM ammonium hydrogen carbonate) and the flow rate was 0.6mLmin -1 . The derived analytes were sensitively detected by multiple reaction monitoring in the positive ion mode. The lower limits of quantitation ranged from 0.06 to 10ngmL -1 with excellent linearity (r≥0.9909). The intra- and inter-day RSD were in the range of 3.6-12% and 5.7-12%, respectively. The recovery rate was 82.5%-95.3%. With this UPLC-MS/MS method, the 11 d-amino acids in hippocampus, cerebral cortex, olfactory bulb and cerebellum from Alzheimer's disease rats and age-matched controls could be simultaneously determined. Compared with the normal controls, the concentrations of d-serine, d-alanine, d-leucine, and d-proline in hippocampus and cerebral cortex of Alzheimer's disease rat brain were significantly decreased, while no differences in olfactory bulb and cerebellum of all the d-amino acids were observed. The different amounts and distribution of d-amino acids in brain between the two groups, which regulated by particular pathological changes of Alzheimer's disease, would give new insights into further study in neuropathogenesis and provide novel therapeutic targets of Alzheimer's disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Bergh, Marianne Skov-Skov; Bogen, Inger Lise; Andersen, Jannike Mørch; Øiestad, Åse Marit Leere; Berg, Thomas
2018-01-01
A novel ion pair reversed phase ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of the stress hormones adrenaline, noradrenaline and corticosterone in rodent blood was developed and fully validated. Separations were performed on an Acquity HSS T3 column (2.1mm i.d.×100mm, 1.8μm) with gradient elution and a runtime of 5.5min. The retention of adrenaline and noradrenaline was substantially increased by employing the ion pair reagent heptafluorobutyric acid (HFBA). Ion pair reagents are usually added to the mobile phase only, but we demonstrate for the first time that including HFBA to the sample reconstitution solvent as well, has a major impact on the chromatography of these compounds. The stability of adrenaline and corticosterone in rodent blood was investigated using the surrogate analytes adrenaline-d 3 and corticosterone-d 8 . The applicability of the described method was demonstrated by measuring the concentration of stress hormones in rodent blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Wang, Ying; Xu, Ranchi; Xiao, Juan; Zhang, Jian; Wang, Xinhong; An, Rui; Ma, Yueming
2014-01-01
Banxia Xiexin decoction (BXD) is an effective Chinese Medicinal Prescription in treating gastroenteritis diseases. In this study an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed to separate and determine 18 major active ingredients of BXD in order to guarantee quality. The separation of ten flavonoids, four alkaloids and four saponins was accomplished on an Acquity BEH C18 (2.1mm×100mm, 1.7μm) column using gradient elution with 0.1% (v/v) formic acid water (A) and 0.1% (v/v) formic acid in methanol (B). All the analytes were detected in positive electrospray ionization tandem mass spectrometry by selective reaction monitoring (SRM) mode. A good linear regression relationship for each analyte was obtained over the range from 2.41-438ng/ml to 20.75-4150ng/ml. The precision was evaluated by intra- and inter-day assays with relative standard deviation (RSD) less than 7.7%. The recovery measured at three concentration levels varied from 92.4% to 107.8%. The method sensitivity expressed as LOQ was typically 0.97-4.15ng/ml. The assay was successfully applied for determination of the 18 bioactive compounds in BXD. The results indicated that the new UPLC-MS/MS method was rapid and accurate, and could be reliably utilized as a quality control method for BXD. Copyright © 2013 Elsevier B.V. All rights reserved.
Wang, Haidong; Yang, Guangsheng; Zhou, Jinyu; Pei, Jiang; Zhang, Qiangfeng; Song, Xingfa; Sun, Zengxian
2016-08-01
In this study, a simple and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for quantitation of droxidopa in human plasma for the first time. A simple plasma protein precipitation method using methanol containing 3% formic acid was selected, and the separation was achieved by an Acquity UPLC™ BEH Amide column (2.1mm×50mm, 1.7μm) with a gradient elution using acetonitrile, ammonium formate buffer and formic acid as mobile phase. The detection of droxidopa and benserazide (internal standard, IS) was performed using positive-ion electrospray tandem mass spectrometry via multiple reaction monitoring (MRM). The precursor-to-product ion transitions m/z 214.2→m/z 152.0 for droxidopa, and m/z 258.1→m/z 139.1 for IS were used for quantification. A lower limit of quantification of 5.00ng/mL was achieved and the linear curve range was 5.00-4000ng/mL using a weighted (1/x(2)) linear regression model. Intra-assay and inter-assay precision was less than 10.2%, and the accuracy ranged from 0.1% to 2.1%. Stability, recovery and matrix effects were within the acceptance criteria recommended by the regulatory bioanalytical guidelines. The method was successfully applied to a pharmacokinetic study of droxidopa in healthy Chinese volunteers. Copyright © 2016. Published by Elsevier B.V.
Bala, Manju; Verma, Praveen Kumar; Awasthi, Shiv; Kumar, Neeraj; Lal, Brij; Singh, Bikram
2015-01-01
A rapid, sensitive, and accurate ultra-performance liquid chromatography coupled with mass spectrometric method (UPLC-MS) was developed and validated for simultaneous determination of four bioactive compounds, syringin (3), cordifolioside A (4), magnoflorine (6) and tinocordiside (10) in the stem of Tinospora cordifolia. The analysis was performed using an Acquity C18 column and gradient elution of 0.05% formic acid in water and acetonitrile at a detection wavelength of 267 nm in 5 min. A high correlation coefficient (r2 > 0.998) indicated good correlation between investigated compounds concentration and their peak area within the test ranges. The LODs for compounds 3, 4, 6 and 10 were 1.95, 0.97, 3.90 and 0.97 ng/mL, respectively, and LOQs were 6.64, 3.20, 12.87 and 3.20 ng/mL, respectively. The overall intra- and inter-day variations of the four compounds were less than 1%. The variation of these four bioactive compounds in T. cordifolia hosted on fifteen different trees was also determined. The compounds (3, 4, 6 and 10) were found in high amount in the T. cordifolia hosted on Azadirachta indica and Mangifera indica as compared with other plants. Twelve compounds were identified on the basis of their mass and UV-vis spectra. The NMR fingerprinting of the extract revealed the presence of alkaloids, fatty acid methyl esters, polysaccharides and marker components of T. cordifolia.
Wang, Shuo; Zhang, Xiangming; Zhang, Jing; Shao, Bing; Li, Shuming
2015-07-01
A method for the determination of 54 drugs in drinking water samples was developed by using ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometry (UPLC-ESI MS/MS). The target drugs in drinking water samples were enriched and cleaned-up by HLB solid-phase extraction (SPE) cartridges and then eluted with 5 mL methanol. The elute was collected, concentrated under a gentle stream of nitrogen gas, diluted with 0.4 mL 0.1% formic acid solution, and analyzed by UPLC-ESI MS/MS. The separation of the 54 drugs was performed on an ACQUITY UPLC™ BEH C18 column using mobile phases of 0.1% formic acid and methanol by gradient elution. The multiple reaction monitoring (MRM) mode was employed in mass spectrometry acquisition. The matrix-matched external standard calibration was used for quantitation. The results showed that the average recoveries of the drugs in ground water, tap water and surface water were 58.7%-104.4%, 53.1%-109.5%, and 50.7%-118.8%, respectively, and the corresponding relative standard deviations (RSD, n=6) were 0.3%-12.8%, 1.0%-15.5%, and 0.4%-19.3%, respectively. The method quantification limits (MQL) for target compounds were in the range of 0.002-5.000 ng/L. The developed method was applied to analyze the water samples from Beijing. The results showed that 26 drugs were detected in ground water samples.
Wang, Tianjiao; Wu, Pinggu; Hu, Zhengyan; Wang, Liyuan; Tang, Jun; Jiang, Wei; Wang, Zhiyuan
2016-07-01
To establish a new qualitative and quantitative ultraperformance liquid chromatography-fluorescence detector / photodiode array detector with series double-detector method for the determination of eleven fluorescent whitening agents in paper food packaging materials. The sample was extracted with 40%acetonitrile water solution, separated by Waters ACQUITY UPLC BEH C_(18)column( 1. 7μm, 2. 1 mm × 100 mm) and eluted gradient. The excitation wavelength and emission wavelength of fluorescence detector( FLD) were 350 nm and 430 nm, and the wavelength of photodiode array detector( PDA) was 350 nm. The detectors were used in series to achieve qualitative and quantitative detection. In the substrates of paper cups, paper bowls, paper trays and paper boxes, those eleven fluorescent whitening agents were separated properly. For both detectors, in the linear range of 25- 1000 ng / m L, the correlation coefficient was greater than 0. 99, and the recoveries of spiked recoveries were between 82. 2%- 104. 1% with the RSD less than 10%( n = 6). The detection limits ofthose eleven fluorescent whitening agents were 0. 20- 0. 28 mg / kg for FLD and 1. 4- 2. 5mg / kg for PDA. The eleven fluorescent whitening agents could be separated properly with complete separation, good shapes and high recovery rate. This method is easy to operate also. Thus it's an effective method to detect the fluorescent whitening agents in paper food packaging materials.
Wang, Lijuan; Ke, Runhui; Wang, Bing; Yin, Jianjun; Song, Quanhou
2012-09-01
An ultra performance liquid chromatography-electrospray ionization tandem mass spectrometric (UPLC-ESI-MS/MS) method was established for the direct determination of ethyl carbamate in Chinese rice wine and grape wine. The Chinese rice wine and grape wine samples were diluted with distilled water, filtered through 0. 22 microm microporous membrane. The LC separation was performed on a Waters Acquity UPLC system with a BEH C18 column, acetonitrile and 0. 1% (v/v) acetic acid aqueous solution as the mobile phase. The ethyl carbamate was determined in the mode of electrospray positive ionization (ESI+) and multiple reaction monitoring (MRM). The butyl carbamate (BC) was used as the internal standard for the quantitative determination. The calibration curve showed good linearity in the range of 2 - 500 microg/L with the correlation coefficient greater than 0.995. The limit of detection (LOD) was 1.7 microg/L and the limit of quantification (LOQ) was 5.0 microg/L. The recoveries of the ethyl carbamate in Chinese rice wine and grape wine was in the range of 90% - 102%. The relative standard deviations (RSDs) of intra-day and inter-day determinations were 0. 8% - 4.5% and 1.4% - 5.6% (n = 6). The results indicated that the proposed method is easy, fast, sensitive, and suitable for the determination of ethyl carbamate in Chinese rice wine and grape wine.
Madhukar, Garg; Tamboli, Ennus Tajuddin; Rabea, Parveen; Ansari, S. H.; Abdin, M. Z.; Sayeed, Ahmad
2014-01-01
Background: Adhatoda vasica a perennial herb has been used in Ayurvedic and Unani system of medicines since last 2000 years and has been employed for the treatment of respiratory tract ailments. Objective: To develop and validate new, rapid, and highly sensitive high throughput ultra-performance liquid chromatography/quadrupole-time-of-flight mass-spectrometry (UPLC/Q-TOF-MS) method for the quantitative estimation of vasicine in the leaves and to establish in vitro cultures of Adhatoda vasica for production of vasicine. Materials and Methods: The chromatographic separation was achieved on a Waters ACQUITY UPLC™ BEH C8 (100.0 × 2.1 mm; 1.7 μm) column packing using isocratic mobile phase consisting of acetonitrile: 20 mM ammonium acetate (90:10; v/v) in a multiple reactions monitoring mode using the transitions m/z 189.09 → 171.08 for vasicine. Results: The vasicine was eluted at 2.58 ± 0.05 min and established a dynamic range of linearity over the concentration range of 1-1000 ng/ml (r2 = 0.999 ± 0.0005). The lower limit of detection and quantification was 0.68 and 1.0 ng/ml, respectively. There was no significant difference observed in the content of vasicine (0.92-1.04%w/w) among the eleven samples collected from different locations of India. The in vitro cultures developed showed that addition of extra 28 mM KNO3 and 100 mM NaCl in MS medium supplemented with 2,4-dichlorophenoxyacetic acid (2,4-D) + benzyladenine (BA) + indole acetic acid (IAA) (1 ppm each) produces faster biomass and higher amount of quinazoline alkaloids. Conclusion: Rapid, efficient, and sensitive UPLC/Q-TOF-MS method was developed for the estimation of vasicine and an efficient protocol for development of in vitro cultures was proposed, which can be used at large scale for industrial production of vasicine using bioreactors. PMID:24914304
Ai, Yu; Wu, Yun; Wang, Fenrong; Ma, Wen; Bian, Qiaoxia; Lee, David Y-W; Dai, Ronghua
2015-03-01
The objective of this study was to develop a sensitive and reliable ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneous quantitation of three monoterpene glycosides (paeoniflorin, alibiflorin and oxypaeoniflorin) and four alkaloids (tetrahydropalmatine, corydaline, dehydrocorydaline and berberine), the main active ingredients of Radix Paeoniae Rubra extract (RPE) and Corydalis yanhusuo extract (CYE) in Huo Luo Xiao Ling Dan (HLXLD), and to compare the pharmacokinetics of these active ingredients in normal and arthritic rats orally administrated with HLXLD or RPE/CYE alone. The analytes and internal standard (IS) (geniposide) were separated on a XBridge C18 column (150 × 4.6 mm, 3.5 µm) using gradient elution with the mobile phase consisting of methanol and 0.01% formic acid in water at a flow rate of 0.6 ml/min. The detection of the analytes was performed on Acquity UPLC-MS/MS system with an electrospray ionization and multiple reaction monitoring mode via polarity switching between negative (for monoterpene glycosides) and positive (for alkaloids) ionization mode. The lower limits of quantification were 2.5, 1, 0.5, 0.2, 0.2, 0.02 and 0.01 ng/ml for paeoniflorin, alibiflorin, oxypaeoniflorin, tetrahydropalmatine, corydaline, dehydrocorydaline and berberine, respectively. Intra-day and inter-day precision and accuracy of analytes were well within acceptance criteria (15%). The mean extraction recoveries of analytes and IS from rat plasma were all more than 83.1%. The validated method has been successfully applied to determination of the analytes. Results showed that there were remarkable differences in pharmacokinetic properties of the analytes between herbal formula and single herb group, normal and arthritic group. Copyright © 2015 John Wiley & Sons, Ltd.
A, Vijaya Bhaskar Reddy; Yusop, Zulkifli; Jaafar, Jafariah; Aris, Azmi B; Majid, Zaiton A; Umar, Khalid; Talib, Juhaizah
2016-09-05
In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis. Copyright © 2016 Elsevier B.V. All rights reserved.
Chomchai, Chulathida; Chomchai, Summon; Kitsommart, Ratchada
2016-05-01
Methamphetamine (MA) use by pregnant women remains a growing problem in South East Asia. After delivery, a negative maternal urine MA assay is assumed to reflect the absence of MA in breast milk and marks breastfeeding initiation. To date, no data exist that describe the relationship between the peripartum and postpartum transfer of MA into breast milk and its urinary excretion in women, following recreational use by smoking. This study aimed to determine the pharmacokinetic of smoked MA in breast milk and its relationship to urinary MA excretion in postpartum women who tested positive for MA before delivery. Timed urine and breast milk samples of 33 women who had positive urine drug screens for MA prior to delivery were analyzed for MA using Acquity Ultra Performance Liquid Chromatography (Waters, Milford, Massachusetts, USA) with the ACQUITY UPLC Photodiode Array Detector (Waters). Those participants with 4 or more timed breast milk samples were included for pharmacokinetic calculation using log-linear trapezoidal rule. Pharmacokinetic data from 2 women were analyzed. The half-life values for MA in the breast milk were 11.3 and 40.3 hours. The absolute infant doses were 21.3 and 51.7 µg/kg/day. Methamphetamine disappears from breast milk approximately 1 day before the maternal urine MA becomes negative. Smoked MA shows a similar breast milk pharmacokinetic pattern to previously reported intravenous MA. Breastfeeding can be safely initiated in mothers whose urine MA screen has turned negative for ≥ 24 hours. However, concurrent maternal substance use treatment and screening is necessary for continued promotion of lactation. © The Author(s) 2015.
Wang, Manman; Wang, Lijuan; Sun, Jinghan; Zhang, Lili; Zhao, Longshan; Xiong, Zhili
2018-03-01
A specific, rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometric (UPLC-MS/MS) method was developed for simultaneous determination of vinpocetine (VP) and its active metabolite, apovincaminic acid (AVA) in rat brain regions, such as hypothalamus, striatum, cortex, cerebellum and hippocampus. Phenacetin was used as internal standard (IS). Brain tissue samples were precipitated protein by using 500 μL methanol. The separation was achieved on a Waters ACQUITY UPLC BEH C18 column (100 mm × 2.1 mm, 1.7 μm), using a methanol-water gradient elution at the flow rate of 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reaction monitoring (MRM) mode via positive electrospray ionization source (ESI). The quantification was operated using the transitions of m/z 351 → m/z 280 for VP, m/z 323 → m/z 280 for AVA and m/z 180 → m/z 110 for IS, respectively. The calibration curve was linear in concentration range from 0.100 to 60.0 ng/mL for VP and 0.103 to 6.18 ng/mL for AVA. The intra-day and inter-day precision (relative standard deviation, RSD) values were within 11.8%, the accuracy (relative error, RE) was from -1.7% to 3.0% for VP and 2.7% to 9.5% for AVA at all the three concentration levels of quality-control (QC) samples. The improved UPLC-MS/MS method was specific, rapid and sensitive, which was further successfully applied to simultaneous determination of VP and AVA in different rat brain regions after intragastric administration of 4 mg/kg VP. It was indicated that VP could be eliminated quickly in brain, while the elimination of AVA was slow and it could be maintained for more than 12 h in brain. Moreover, it was found that the contents of VP and AVA were much higher in the hypothalamus, striatum and cortex than those in the cerebellum and hippocampus, which verified the distribution characteristics of VP and AVA in different brain regions from the point of quantitation in rats.
Zhang, Ming; Tang, Fangliang; Xu, Jianfen; Yu, Bo; Zhang, Wei; Yao, Jianliang; Hu, Minhua
2017-10-08
A high-throughput detection method has been developed for the determination of nine perfluorinated compound precursors (PFCPs) in atmospheric precipitation by solid phase extraction-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (SPE-UPLC-ESI-MS/MS). The atmospheric precipitation samples were concentrated and purified with HLB solid phase extraction cartridges. The UPLC separation was performed on an HSS T 3 column (100 mm×2.1 mm, 1.7 μm) utilizing a gradient elution program of methanol and water as the mobile phases at a flow rate of 0.2 mL/min. The MS/MS detection was performed under negative electrospray ionization (ESI - ) in multiple reaction monitoring (MRM) mode. Good linearity was observed in the range of 0.05-5.00 μg/L, 0.50-50.0 μg/L or 5.00-500 μg/L with correlation coefficients from 0.9921 to 0.9995. The limits of detection (LODs) for the nine perfluorinated compound precursors were in the ranges of 0.05-7.9 ng/L. The recoveries ranged from 76.0% to 106% with the relative standard deviations between 0.72% and 13.7%. This method is characterized by high sensitivity and precision, extensive analytical range and quick analytical rate, and can be applied for the analysis of perfluorinated compound precursors in atmospheric precipitation.
Lu, Yuejuan; Li, Ning; Deng, Ying; Zhao, Longshan; Guo, Xingjie; Li, Famei; Xiong, Zhili
2015-07-01
A rapid, sensitive and selective ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed and validated for the simultaneous determination of icariin, naringin and osthole in rat plasma. Plasma samples pretreatment involved a one-step liquid-liquid extraction with a mixture of ethyl acetate-methyl tert-butyl ether (3:1, ν/ν). The separation was performed on an ACQUITY UPLC™ BEH C18 column with a gradient mobile phase system of methanol and water. The detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization (ESI) by multiple reactions monitoring (MRM), with the transitions at m/z 513.3→366.8 (icariin), m/z 579.3→150.9 (naringin), m/z 245.1→189.0 (osthole) and m/z 237.1→194.1 (IS), respectively. A good linear response was observed over the concentration ranges of 1.06-424ng/ml, 2.10-525ng/ml and 1.05-1.05×10(3)ng/ml with lower limit of quantification (LLOQ) of 1.06, 2.10 and 1.05ng/ml for icariin, naringin and osthole, respectively. The intra- and inter-day precisions (R.S.D.) were within 14.3%, and the accuracy (R.E.) ranged from -4.1% to 4.6% at three quality control levels. The sensitive and selective method was applied to a pharmacokinetic study of icarrin, naringin and osthole in rats after oral administration of Gushudan capsule. Copyright © 2015 Elsevier B.V. All rights reserved.
Kryczyk, Agata; Żmudzki, Paweł; Hubicka, Urszula
2016-11-01
A simple and reproducible UPLC-MS/MS method for the determination of itraconazole (ITZ) and its photodegradation products formed during exposure to UV-A radiation was developed. Chromatographic separations were carried out using an Acquity UPLC BEH C 18 column (2.1 × 100 mm, 1.7 μm particle size). The column was maintained at 40°C, and eluted under gradient conditions from 100% to 50% of eluent A over 13 min, at a flow rate of 0.3 mL min -1 . Eluent A was 0.1% (v/v) formic acid in water; eluent B was 0.1% (v/v) formic acid in acetonitrile. The linear regression analysis for the calibration curve showed a good linear correlation over the concentration range 0.0066-0.15 mg mL -1 with determination coefficient > 0.99. The activities of some photocatalysts during degradation process of ITZ were compared. It was found that indirect photodegradation of ITZ was more effective than direct photolysis. Under our experimental conditions the photodegradation rate constant depended on the applied catalysts with catalytic activity decreasing in the following pattern: FeCl 3 > TiO 2 /FeCl 3 > TiO 2 . The kinetic analysis of the photodegradation data revealed that the degradation of the ITZ follows first-order kinetics. The photodegradation products of ITZ were identified, and their fragmentation pathways, derived from MS/MS data, were proposed. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Giménez, Estela; Gay, Marina; Vilaseca, Marta
2017-01-30
Here we demonstrate the potential of nano-UPLC-LTQ-FT-MS and the Byonic™ proteomic search engine for the separation, detection, and identification of N- and O-glycopeptide glycoforms in standard glycoproteins. The use of a BEH C18 nanoACQUITY column allowed the separation of the glycopeptides present in the glycoprotein digest and a baseline-resolution of the glycoforms of the same glycopeptide on the basis of the number of sialic acids. Moreover, we evaluated several acquisition strategies in order to improve the detection and characterization of glycopeptide glycoforms with the maximum number of identification percentages. The proposed strategy is simple to set up with the technology platforms commonly used in proteomic labs. The method allows the straightforward and rapid obtention of a general glycosylated map of a given protein, including glycosites and their corresponding glycosylated structures. The MS strategy selected in this work, based on a gas phase fractionation approach, led to 136 unique peptides from four standard proteins, which represented 78% of the total number of peptides identified. Moreover, the method does not require an extra glycopeptide enrichment step, thus preventing the bias that this step could cause towards certain glycopeptide species. Data are available via ProteomeXchange with identifier PXD003578. We propose a simple and high-throughput glycoproteomics-based methodology that allows the separation of glycopeptide glycoforms on the basis of the number of sialic acids, and their automatic and rapid identification without prior knowledge of protein glycosites or type and structure of the glycans. Copyright © 2016 Elsevier B.V. All rights reserved.
Liu, Ping; Fan, Sai; Wu, Guohua; Zhao, Rong; Liu, Wei; Zhao, Xudong
2016-05-01
A method for the simultaneous determination of 6 plant growth regulator (PGR) residues in bean sprout was developed by ultra high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS). 6-Benzylaminopurine, isopentennyladenine, 4-chlorophenoxyacetic acid, 4-fluorophenoxyacetic acid, indole-3- acetic acid and indole-3-butyric acid were concerned. Bean sprout samples were extracted by acetonitrile and QuEChERS extraction kit, purified by C18 powers. After centrifugation, the sample liquids was diluted 10 times by ultrapure water. The chromatographic analysis was carried out on an waters acquity UPLC BEH C18 column( 100 mm x 2.1 mm, 1.7 microm). The analyzer confirmed and quantified by mass spectrum of triple quadrupole in the multiple reaction monitoring (MRM) mode and quantified by matrix-matched external standard method. The calibration curves showed good linearity in each range with correlation coefficients greater than 0.998. 3 levels spiked recoveries were carried out using blank bean sprout extraction as substrate, the recoveries ranged from 84.2% to 107.5%, the relative standard deviations (RSDs) ranged from 3.08% to 12.71%. The qualitative limits of detections (S/N = 3) were 0.03-3.0 microg/kg and the quantitative limits(S/N = 10) were 0.1-10.0 microg/kg for the 6 PGRs. The method is simple and easy to operate, with less organic reagent, high sensitivity and good stability. It is suitable for the detection of 6 kinds of plant growth regulators in bean sprouts.
Kumar, Namala Durga Atchuta; Babu, K. Sudhakar; Gosada, Ullas; Sharma, Nitish
2012-01-01
Introduction: A selective, specific, and sensitive “Ultra High-Pressure Liquid Chromatography” (UPLC) method was developed for determination of candesartan cilexetil impurities as well asits degradent in tablet formulation. Materials and Methods: The chromatographic separation was performed on Waters Acquity UPLC system and BEH Shield RP18 column using gradient elution of mobile phase A and B. 0.01 M phosphate buffer adjusted pH 3.0 with Orthophosphoric acid was used as mobile phase A and 95% acetonitrile with 5% Milli Q Water was used as mobile phase B. Ultraviolet (UV) detection was performed at 254 nm and 210 nm, where (CDS-6), (CDS-5), (CDS-7), (Ethyl Candesartan), (Desethyl CCX), (N-Ethyl), (CCX-1), (1 N Ethyl Oxo CCX), (2 N Ethyl Oxo CCX), (2 N Ethyl) and any unknown impurity were monitored at 254 nm wavelength, and two process-related impurities, trityl alcohol and MTE impurity, were estimated at 210 nm. Candesartan cilexetil andimpurities were chromatographed with a total run time of 20 min. Results: Calibration showed that the response of impurity was a linear function of concentration over the range limit of quantification to 2 μg/mL (r2≥0.999) and the method was validated over this range for precision, intermediate precision, accuracy, linearity, and specificity. For the precision study, percentage relative standard deviation of each impurity was <15% (n=6). Conclusion: The method was found to be precise, accurate, linear, and specific. The proposed method was successfully employed for estimation of candesartan cilexetil impurities in pharmaceutical preparations. PMID:23781475
Xie, Xiuman; Sun, Wanyang; Miao, Jingzhuo; Huang, Jingyi; Xu, Jingyao; Liu, Xiaolin; Sun, Henry; Tong, Ling; Sun, Guoxiang
2016-06-01
7'(Z)-(8″S, 8‴S)-epi-Salvianolic acid E (compound 1) and (7'R, 8'R, 8″S, 8‴S)-epi-salvianolic acid B (compound 2), two novel analogs of salvianolic acid B (Sal B), have been recently isolated from Salvianolic acid for injection. They both show powerful antioxidant effects, including inducing NQO1 activity and scavenging DPPH free radical, and potential protecting effects for cerebral ischemia. However, no reports have been described the pharmacokinetic study of them. In this study, an ultra-fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS) method was developed and validated for the determination of compound 1, compound 2 and Sal B in rat plasma, respectively. Plasma samples were pretreated by liquid-liquid extraction with ethyl acetate. Chromatographic separation was achieved on a Waters Acquity UPLC(®) HSS T3 column (1.7μm particles, 2.1mm i.d.×100mm) with the mobile phase of 0.1% aqueous formic acid (A)-acetonitrile (B) (65:35, v/v). Quantification was performed on a triple quadruple tandem mass spectrometry with electrospray ionization (ESI) by multiple reaction monitoring (MRM) in the negative ion mode. Monitored transitions were set at m/z 717.0→519.0, 717.1→519.1, 717.2→518.9 and 320.9→152.1 for compound 1, compound 2, Sal B and chloramphenicol (internal standard, IS), respectively. Linear calibration curves were acquired over the concentration range of 2.0-1000ng/mL for the three analytes in rat plasma. The extraction recoveries, matrix effects, intra- and inter-day precisions and accuracies of the three analytes were all within acceptable limits. The validated method was successfully applied to the pharmacokinetic study of compound 1, compound 2 and Sal B after intravenous administration of 6.0mg/kg in rats, respectively. The results indicated that compound 1 and compound 2 were both eliminated more slowly than Sal B. Exposure levels of both compound 1 and Sal B were higher than compound 2 in the same dosage range. This study provided critical reference for the pharmacokinetic study of compound 1 and compound 2. Copyright © 2016 Elsevier B.V. All rights reserved.
Liuzzi, Vania C; Mirabelli, Valentina; Cimmarusti, Maria Teresa; Haidukowski, Miriam; Leslie, John F; Logrieco, Antonio F; Caliandro, Rocco; Fanelli, Francesca; Mulè, Giuseppina
2017-01-25
Members of the fungal genus Fusarium can produce numerous secondary metabolites, including the nonribosomal mycotoxins beauvericin (BEA) and enniatins (ENNs). Both mycotoxins are synthesized by the multifunctional enzyme enniatin synthetase (ESYN1) that contains both peptide synthetase and S-adenosyl-l-methionine-dependent N -methyltransferase activities. Several Fusarium species can produce ENNs, BEA or both, but the mechanism(s) enabling these differential metabolic profiles is unknown. In this study, we analyzed the primary structure of ESYN1 by sequencing esyn1 transcripts from different Fusarium species. We measured ENNs and BEA production by ultra-performance liquid chromatography coupled with photodiode array and Acquity QDa mass detector (UPLC-PDA-QDa) analyses. We predicted protein structures, compared the predictions by multivariate analysis methods and found a striking correlation between BEA/ENN-producing profiles and ESYN1 three-dimensional structures. Structural differences in the β strand's Asn789-Ala793 and His797-Asp802 portions of the amino acid adenylation domain can be used to distinguish BEA/ENN-producing Fusarium isolates from those that produce only ENN.
Xiong, Wei; Zhao, Jiajia; Wang, Ling; Jiang, Xuehua
2017-06-01
Cigarette smoke is known to interact with tamoxifen-metabolizing enzymes and transporters and potentially affect its treatment outcome. 4-(N-nitrosomethylamino)-1-(3-pyridyl)-1-butanol (NNAL) is an important metabolite of 4-(methylnitro-samino)-1-(3-pyridyl)-1-butanone (NNK) because it is frequently used as a biomarker to assess human smoke exposure. In order to study the potential pharmacokinetic interaction between cigarette smoke and tamoxifen in rats a UPLC-MS/MS method for the simultaneous determination of NNAL and tamoxifen along with its metabolites in rat plasma has been developed and validated. Analytes were extracted with methanol and separated on a HSS T3 column by a gradient elution with the mobile phase consisting of acetonitrile and water. The lower limits of quantitation ranged from 0.05 to 0.62 ng/mL. Precisions showed RSD <15.8% and accuracy in the range 80.6-116.0%. Mean analyte recoveries ranged from 76.9 to 108.4%. The method was successfully applied to study the effects of cigarette smoke condensate (CSC), NNK and benzo(a)pyrene pre-treatment on the pharmacokinetics of tamoxifen and its metabolites in rats. Significant effects of CSC, NNK, benzo(a)pyrene were observed on pharmacokinetics of tamoxifen and its metabolites. We also found that plasma NNAL levels are statistically significant correlated with plasma 4-hydroxy-tamoxifen and endoxifen. Copyright © 2016 John Wiley & Sons, Ltd.
Jadhav, Sushant Bhimrao; Kumar, C Kiran; Bandichhor, Rakeshwar; Bhosale, P N
2016-01-25
A new UPLC-TOF/MS compatible, reverse phase-stability indicating method was developed for determination of Omeprazole (OMP) and its related substances in pharmaceutical dosage forms by implementing Design of Experiment (DoE) i.e. two level full factorial Design (2(3)+3 center points=11 experiments) to understand the Critical Method Parameters (CMP) and its relation with Critical Method Attribute (CMA); to ensure robustness of the method. The separation of eleven specified impurities including conversion product of OMP related compound F (13) and G (14) i.e. Impurity-I (1), OMP related compound-I (11) and OMP 4-chloro analog (12) was achieved in a single method on Acquity BEH shield RP18 100 × 2.1 mm, 1.7 μm column, with inlet filter (0.2 μm) using gradient elution and detector wavelength at 305 nm and validated in accordance with ICH guidelines and found to be accurate, precise, reproducible, robust and specific. The drug was found to degrade extensively in heat, humidity and acidic conditions and forms unknown degradation products during stability studies. The same method was used for LC-MS analysis to identify m/z and fragmentation of maximum unknown impurities (Non-Pharmacopoeial) i.e. Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9) formed during stability studies. Based on the results, degradation pathway for the drug has been proposed and synthesis of identified impurities i.e. impurities (Impurity-I (1), Impurity-III (3), Impurity-V (5) and Impurity-VIII (9)) are discussed in detail to ensure in-depth understanding of OMP and its related impurities and optimum performance during lifetime of the product. Copyright © 2015. Published by Elsevier B.V.
Och, Marek; Och, Anna; Cieśla, Łukasz; Kubrak, Tomasz; Pecio, Łukasz; Stochmal, Anna; Kocki, Janusz; Bogucka-Kocka, Anna
2015-06-01
The demand for podophyllotoxin and deoxypodophyllotoxin is still increasing and commercially exploitable sources are few and one of them, Podophyllum hexandrum Royle (Berberidaceae), is a "critically endangered" species. The first aim was to quantify the amount of podophyllotoxin and deoxypodophyllotoxin in 61 Juniperus (Cupressaceae) samples. Cytotoxic activity of podophyllotoxin and ethanolic leaf extracts of Juniperus scopulorum Sarg. "Blue Pacific" and Juniperus communis L. "Depressa Aurea" was examined against different leukemia cell lines. Ultra-performance liquid chromatography (UPLC) analysis was performed with the use of a Waters ACQUITY UPLC(TM) system (Waters Corp., Milford, MA). The peaks of podophyllotoxin and deoxypodophyllotoxin were assigned on the basis of their retention data and mass-to-charge ratio (m/z). Trypan blue assay was performed to obtain IC50 cytotoxicity values against selected leukemia cell lines. Juniperus scopulorum was characterized with the highest level of podophyllotoxin (486.7 mg/100 g DW) while Juniperus davurica Pall. contained the highest amount of deoxypodophyllotoxin (726.8 mg/100 g DW). Podophyllotoxin IC50 cytotoxicity values against J45.01 and CEM/C1 leukemia cell lines were 0.0040 and 0.0286 µg/mL, respectively. Juniperus scopulorum extract examined against J45.01 and HL-60/MX2 leukemia cell lines gave the respective IC50 values: 0.369-9.225 µg/mL. Juniperus communis extract was characterized with the following IC50 cytotoxity values against J45.01 and U-266B1 cell lines: 3.310-24.825 µg/mL. Juniperus sp. can be considered as an alternative source of podophyllotoxin and deoxypodophyllotoxin. Cytotoxic activity of podophyllotoxin and selected leaf extracts of Juniperus sp. against a set of leukemia cell lines was demonstrated.
Bajrai, Amal A; Ezzeldin, Essam; Al-Rashood, Khalid A; Raish, Mohammad; Iqbal, Muzaffar
2016-03-01
Lorcaserin is a novel, potent and highly efficacious 5-HT2C receptor agonist, recently approved by US Food and Drug Administration for the treatment of obesity. It has some abuse potential also and is listed as a Schedule IV drug in the Controlled Substances Act. Herein, a sensitive, selective and reliable UPLC-MS-MS assay was developed and validated for the quantitative analysis of lorcaserin in rat plasma and brain tissue using carbamazepine as an internal standard (IS). After the extraction of samples by protein precipitation, both lorcaserin and IS were separated on an Acquity BEH™ C18 (50 × 2.1 mm, 1.7 µm) column using a mobile phase consisting of acetonitrile-10 mM ammonium acetate-formic acid (85:15:0.1, v/v/v) at a flow rate of 0.25 mL/min. Detection and quantification were performed on a positive electrospray ionization interface in the multiple-reaction monitoring (MRM) mode. The MS-MS ion transitions were monitored at m/z 195.99 > 143.91 for lorcaserin and m/z 237.00 > 178.97 for IS, respectively. The calibration curves were linear over a concentration range of 1.08-500 ng/mL in plasma and 3.07-500 ng/mL in brain tissue homogenates, respectively. All the validation parameters results were within the acceptable range described in guidelines for bioanalytical method validation. The assay was successfully applied in a pharmacokinetic study of lorcaserin after oral administration in rats. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Lu, Baiyi; Ren, Yiping; Huang, Baifen; Liao, Wenqun; Cai, Zengxuan; Tie, Xiaowei
2008-03-01
A novel ultra-performance liquid chromatography electrospray ionization tandem triple quadrupole mass spectrometry method for the simultaneous determination of four water-soluble vitamins, including vitamin B5 (VB5), vitamin B8 (VB8), vitamin B9 (VB9), and vitamin B12 (VB12) in fortified infant foods is developed and validated. A reverse phase UPLC separation system consisting of a Waters ACQUITY UPLC BEH C-18 column (2.1 mm x 100 mm i.d., 1.7 microm) and a binary gradient acetonitrile-water mobile phase is applied for the separation of the four water-soluble vitamins. Formic acid is spiked into the mobile phase to enhance the ionization efficiency. Tandem MS-MS analysis is performed in multi-reaction monitoring mode (MRM). Product-ion traces at m/z 220.1 --> 89.9 for VB5, 245.1 --> 227.1 for VB8, 442.3 --> 295.2 for VB9, and 678.9 --> 147.0 for VB12 are used for quantitation of the corresponding vitamins, and traces at m/z 455.5 --> 308.0 are used for methotrexate (internal standard). Limits of quantitation (LOQs) are 0.016, 0.090, 0.020, and 0.019 microg/L for VB5, VB8, VB9, and VB12, respectively. Intra- and inter-day precisions for the determination of the four vitamins are better than 6.84% and 12.26% in relative standard deviations, and recoveries for the four vitamins are in the range of 86.0~101.5%. The developed approach is applied for the determination of the trace amounts of the vitamins in fortified milk powers and fortified rice powers.
Fernández, P; González, M; Regenjo, M; Ares, A M; Fernández, A M; Lorenzo, R A; Carro, A M
2017-02-17
A miniaturized and simple method based on digitally programmed microextraction by packed sorbent (eVol ® -MEPS) coupled to ultra-performance liquid chromatography (UPLC) has been developed for quantitative determination of three synthetic cathinones and seven conventional drugs of abuse and metabolites. The influence of several extraction parameters, such as washing and elution solvents were tested. In addition important variables affecting MEPS performance, namely sample volume, sorbent drying time, washing solvent volume, elution volume, number of extraction cycles, sorbent phase and pH, were evaluated using an asymmetrical screening design. The optimal experimental conditions involved 300μL of plasma, loading 10×100μL of sample through a C8/SCX sorbent in a MEPS syringe placed in the semi-automatic eVol ® system, washing using 150μL H 2 O:MeOH (90:10, v/v), drying for 0.5min and elution using 200μL dichloromethane:2-propanol:ammonium hydroxide (78:20:2, v/v/v). The drugs separation was achieved using an ACQUITY BEH Shield RP18 column (2.1mm×100mm×1.7μm) in 3min. Under optimized conditions the proposed method was validated in terms of selectivity, linearity, limits of detection (LOD) and quantitation (LOQ), precision and matrix effect, using standard addition calibration. The combination of MEPS and UPLC provides a method for the primary screening of the analytes in 18min with excellent recoveries at three concentration levels, ranging between 80 and 104% (relative standard deviation <11%). The developed methodology has been successfully applied to plasma samples from polydrug abusers. Copyright © 2017 Elsevier B.V. All rights reserved.
Wu, Li-Lan; Wu, Yun-Shan; Chen, Wei-Ying; Zhou, Wen; Tang, Lipeng; Li, Ben; Liu, Bo
2017-07-15
Artemisitene shows a wide variety of pharmacological activities, such as antioxidant protection in vitro and in vivo. It has been identified as a novel Nrf2 inducer. However, there is no report on an ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) method to quantitate artemisitene in rat plasma and its application to a pharmacokinetic profile study. An ACQUITY UPLC™ BEH Symmetry Shield RP18 column (1.7 μm, 2.1 mm × 100 mm) was used at a flow rate of 0.3 mL·min -1 . Mass detection was performed by electrospray ionization tandem mass spectrometry via multiple reaction monitoring (MRM) in positive mode. Plasma samples were pre-treated by a single-step extraction with 0.1% formic acid aqueous solutions-acetonitrile, and tolbutamide was used as internal standard. The calibration curve was from 0.98 to 1000 ng∙mL -1 (r 2 = 0.995). The extraction recoveries were 61.5-79.4% and 81.7-94.6% for artemisitene and tolbutamide, respectively. The lower limit of quantification (LLOQ) was 0.98 ng∙mL -1 . The absolute bioavailability of artemisitene was 3.7% after intravenous and oral administration in rats. The UPLC/MS/MS assay was validated for linearity, accuracy, stability, extraction recovery, matrix effects, and intra-day and inter-day precision. The method, for the first time, achieved some pharmacokinetic parameters and was successfully applied to a pharmacokinetic study Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Effect of aspirin on the pharmacokinetics and absorption of panax notoginseng saponins.
Tian, Zhihao; Pang, Huanhuan; Zhang, Qiang; Du, Shouying; Lu, Yang; Zhang, Lin; Bai, Jie; Li, Pengyue; Li, Danqi; Zhao, Mengdi; Chen, Xiaonan
2018-02-01
Panax notoginseng saponins, a traditional Chinese medicine extraction, and aspirin are both widely used to treat cerebral infarction in China. Good results in clinical practice have been achieved, when Panax notoginseng saponins was taken together with aspirin. To investigate the interaction of the two drugs in vivo, the concentration of notoginsenoside R 1 , ginsenoside Rg 1 , Rb 1 , Re and Rd. in blood were simultaneously measured by UPLC/MS/MS. Sample preparation was carried out by the protein precipitation technique with an internal standard saikosaponin A standard. The separation of six components was achieved by using an ACQUITY UPLC ®BEH C18 column (1.7μm 2.1×100mm) by gradient elution using water (containing 0.2% formic acid) and acetonitrile (containing 0.2% formic acid) as the mobile phase at a flow rate of 0.2mL/min. The pharmacokinetic parameters were determined using non-compartmental analysis. The transport of notoginsenoside R 1 , ginsenoside Rg 1 , Rb 1 , Re and Rd. in MDCK -MDR1 cell monolayer was also used to verify the conclusion of pharmacokinetic drug-drug interaction and study the mechanism of drug interaction. The concentrations of the five components increased in a certain extent when the two drugs administered together in rats. The values of apparent permeability coefficients were significantly increased when the two drugs were used together. Aspirin and salicylic acid could destroy the tight junction protein and open the intercellular space to increase the absorption of Panax notoginseng saponins. Pharmacokinetic drug-drug interaction in vivo existed between Panax notoginseng saponins and aspirin. The drug-drug interaction mainly occurred in the process of absorption. Copyright © 2018 Elsevier B.V. All rights reserved.
Chavarria, Jesus; Rueger, Sandra Y; King, Andrea C
2018-04-16
Alcohol hangovers have been found to be a common and costly consequence of alcohol misuse. However, there is only limited psychometric support for instruments to accurately measure hangovers beyond the college-age years. This study investigated the psychometric properties of the Hangover Symptom Scale (HSS) and the Hangover Symptom Scale-Short Form (HSS-5) including the internal consistency, convergent and discriminant validity, construct validity, and the measurement invariance of these scales between light and heavy drinkers, individuals with a positive and negative family history of alcohol use disorder (AUD), and men and women in a post-college-aged sample. The association of the HSS and HSS-5 with alcohol use problems was also tested. Participants were 294 nonalcoholic light and heavy social drinkers (age range 21 to 35 years; 57.8% male) enrolled in the Chicago Social Drinking Project. They completed the HSS as part of a take-home packet completed outside of the laboratory. The psychometric properties of the HSS and HSS-5 were tested. Stronger psychometric support was found for the HSS-5 relative to the full HSS. While both measures demonstrated strong internal consistency reliability, convergent and discriminant validity, and an association with alcohol use problems, only the HSS-5 showed construct validity as determined by confirmatory factor analysis. Further, only the HSS-5 showed measurement invariance between men and women, light and heavy drinkers, and individuals with a positive and negative family history of AUD. This was the first study to examine the psychometric properties of the HSS and HSS-5 in a post-college-aged sample and the first to investigate the measurement invariance of these measures as a function of sex, drinking history, and family history of AUD. This study supports the use of the HSS-5 as a reliable and valid brief measure of frequency of hangover symptoms. Copyright © 2018 by the Research Society on Alcoholism.
[Determination of aconitine, hypaconitine and mesaconitine in Shenfu injection].
Zhang, Pan-Pan; Zhang, Jun-Zhen; Wang, Zhao-Hong; Lu, Yong-Jiang; Jiang, Ye
2013-05-01
To establish a method for the content determination of indexes for measuring aconitic compounds contained in Shenfu injection, in order to provide basis for the evaluation of the curative effect of monkshood in Shenfu injection. The sample were purified and enriched with HF-LPME. ACQUITY UPLC BEH C18 column (2.1 mm x 50 mm, 1.7 microm) was adopted and eluted with a gradient program, with acetonitrile-10 mmol x L(-1) NH4HCO3 (pH 10) as the mobile phases. The flow rate was 0.45 mL x min(-1). The content was determined with ESI and MRM. The results showed that aconitine, hypaconitine and mesaconitine showed a good linear relationship, with r > 0.999, within the range of 0.1-100 ng x L(-1). The recoveries were detected to be 100.1%, 97.4%, 97.5%, with RSD being 1.2%, 1.1%, 1.5%, respectively. This method was used to prove the safety of Shenfu injection, and provide scientific basis for correct evaluation of curative effect of monkshood, as well as a reliable, simple and practical means for quality control of monkshood-containing Chinese materia medica preparations.
LC-MS/MS assay for the quantitation of the tyrosine kinase inhibitor neratinib in human plasma.
Kiesel, Brian F; Parise, Robert A; Wong, Alvin; Keyvanjah, Kiana; Jacobs, Samuel; Beumer, Jan H
2017-02-05
Neratinib is an orally available tyrosine kinase inhibitor targeting HER2 (ERBB2) and EGFR (ERBB). It is being clinically evaluated for the treatment of breast and other solid tumors types as a single agent or in combination with other chemotherapies. In support of several phase I/II clinical trials investigating neratinib combinations, we developed and validated a novel LC-MS/MS assay for the quantification of neratinib in 100μL of human plasma with a stable isotopic internal standard. Analytes were extracted from plasma using protein precipitation and evaporation of the resulting supernatant followed by resuspension. Chromatographic separation was achieved using an Acquity UPLC BEH Shield RP18 column and a gradient methanol-water mobile phase containing 10% ammonium acetate. An ABI 4000 mass spectrometer and electrospray positive mode ionization were used for detection. The assay was linear from 2 to 1,000ng/mL and proved to be accurate (98.9-106.5%) and precise (<6.2%CV), and met the FDA guidance for bioanalytical method validation. This LC-MS/MS assay will be an essential tool to further define the pharmacokinetics of neratinib. Copyright © 2016 Elsevier B.V. All rights reserved.
Qi, Chao; Cai, Qianqian; Zhao, Pan; Jia, Xiuna; Lu, Nan; He, Lu; Hou, Xiaohong
2016-06-03
Metal-organic framework MIL-101(Cr) was successfully used as an efficient sorbent in a vortex-assisted dispersive solid-phase extraction (VA-DSPE) and applied for the determination and the pharmacokinetic of imatinib mesylate in rat plasma by UPLC-MS/MS. In the enrichment of imatinib from rat plasma, the analyte was efficiently adsorbed on MIL-101(Cr) and simply recovered by using initial mobile phase (0.1% formic acid-methanol (6:4 v/v)) as elution solvent. Meanwhile, the protein in the plasma samples was excluded from the porous structure of MIL-101(Cr), leading to direct extraction of drug molecule from protein-rich biological samples without any other pretreatment procedure. After being removed, the supernatant was filtered and directly injected into the UPLC-MS/MS for the analysis of the target. The experimental parameters, including nature of MOFs, amount of MIL-101(Cr), pH value of aqueous solution, extraction time, type and volume of elution solvent, were systematically optimized. After VA-DSPE, chromatographic separation was performed on an ACQUITY UPLC(®) BEH C18 column (2.1mm×100mm, 1.7μm) with a 3min gradient elution using 0.1% formic acid and methanol as mobile phase at a flow rate of 0.3mL/min. The detection was accomplished on a tandem mass spectrometer via an electrospray ionization (ESI) source by multiple reaction monitoring (MRM) in the positive ionization mode. The lower limit of quantification of 1ng/mL was achieved and the mean recovery of the analyte was higher than 81.2%. Moreover, computational simulation was primarily applied to predict the adsorption behavior and revealed the molecular interactions and free binding energies between MIL-101(Cr) and imatinib with the molecular modeling method, providing certain explanation of the adsorption mechanism. The originally established pretreatment and detection method has some merits, such as less solvent consumption, easy operation, higher sensitivity and lower matrix effect. And the MIL-101(Cr) exhibited a potential as an efficient sorbent in the enrichment of the analyte from complex biosamples. Copyright © 2016 Elsevier B.V. All rights reserved.
Sugiura, Koichi; Min, Jun Zhe; Toyo'oka, Toshimasa; Inagaki, Shinsuke
2008-09-26
The rapid, sensitive and simultaneous determination of six polyamines, i.e., ornithine (ORN), 1,3-diaminopropane (DAP), putrescine (PUT), cadaverine (CAD), spermidine (SPD) and spermine (SPM), in human hairs was performed by ultra-performance liquid chromatography (UPLC) with fluorescence (FL) detection and electrospray-ionization time-of-flight mass spectrometry (ESI-TOF-MS). The primary (-NH(2)) and secondary (-NH) amines in the polyamine structures were first labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 30 min in the mixture of 0.1M borax (pH 9.3) and acetonitrile (CH(3)CN). The resulting derivatives were perfectly separated using an ACQUITY UPLC BEH C(18) column (1.7 microm, 100 mm x 2.1mm i.d.) by a gradient elution with a mixture of water-acetonitrile containing 0.1% formic acid (HCOOH). The separated polyamine derivatives were sensitively detected with both FL and TOF-MS. The detection limits in FL and TOF-MS were 11-86 and 2-5 fmol, respectively. However, the determination of several polyamines by FL detection was interfered with by endogenous substances in the hair. Therefore, the simultaneous determination in hair was carried out by the combination of UPLC separation and the ESI-TOF-MS detection. The structures of the polyamines were identified from the protonated-molecular ions [M+H](+) obtained from the TOF-MS measurement. A good linearity was achieved from the calibration curves, that was obtained by plotting the peak area ratios of the analytes relative to the internal standard (IS), i.e., 1,6-diaminohexane (DAH), against the injected amounts of each polyamine (0.05-50 pmol, r(2)>0.999). The proposed method was applied to the determination in the hairs of healthy volunteers. The mean concentrations of ORN, DAP, PUT, CAD, SPD and SPM in 1mg of human hairs (n=20) were 1.46, 0.18, 1.18, 0.11, 1.97 and 0.98 pmol, respectively. Because the proposed method provides a good mass accuracy and the trace detection of the polyamines in hair, this analytical technique seems to be applicable for the determination of various biological compounds in hair.
Adult correlates of early behavioral maladjustment: a study of injured drivers.
Ryb, Gabriel; Dischinger, Patricia; Smith, Gordon; Soderstrom, Carl
2008-10-01
To establish whether a history of school suspension (HSS) predicts adult driver behavior. 323 injured drivers were interviewed as part of a study of psychoactive substance use disorders (PSUD) and injury. Drivers with a HSS were compared to those without HSS in relation to demographics, SES, PSUD, risky behaviors, trauma history and driving history using student's t test and chi-square. Multiple logistic regression models were constructed to adjust for demographics, SES and PSUD. HSS drivers represented 31% of the population and were younger, more likely to be male and had higher rates of alcohol and drug dependence than drivers without HSS. Educational achievement was worse for drivers with HSS. Drivers with HSS were more likely to have a history of prior vehicular trauma and assault. Seat-belt non-use, drinking and driving, riding with drunk driver, binge drinking, driving fast for the thrill, license suspension and drinking and driving convictions were more common among drivers with HSS. In multiple logistic regression models adjusting for demographics and SES, HSS revealed higher odds ratios for the same outcomes. After adding PSUD to the models HSS remained significant only for seat belt non use, binge drinking and previous assault history. HSS is associated with risky behaviors, repeated vehicular injury, and poor driver history. The association with driver history, however, disappears when PSUD are included in the models. The association of HSS (a marker of early behavioral maladjustment) with behavioral risks suggests that undiagnosed psychopathology may be linked to injury recidivism.
Dong, Kai; Zhang, Hefeng; Yan, Yan; Sun, Jinyao; Dong, Yalin; Wang, Ke; Zhang, Lu; Shi, Xianpeng; Xing, Jianfeng
2017-03-01
Extensive or long-time use of corticosteroids often causes many toxic side-effects. The ion exchange resins and the coating material, Eudragit, can be used in combination to form a new oral delivery system to deliver corticosteroids. The resin microcapsule (DRM) composed by Amberlite 717 and Eudragit S100 was used to target hydrocortisone (HC) to the colon in order to improve its treatment effect on ulcerative colitis (UC) and reduce its toxic side-effects. Hydrocortisone sodium succinate (HSS) was sequentially encapsulated in Amberlite 717 and Eudragit S100 to prepare the HSS-loaded resin microcapsule (HSS-DRM). The scanning electron microscopy (SEM) was employed to investigate the morphology and structure of HSS-DRM. The in vitro release and in vivo studies of pharmacokinetics and intestinal drug residues in rat were used to study the colon-targeting of HSS-DRM. The mouse induced by 2,4,6-trinitrobenzenesulfonic acid was used to study the treatment of HSS-DRM on experimental colitis. SEM study showed good morphology and structure of HSS-DRM. In the in vitro release study, > 80% of HSS was released in the colon environment (pH 7.4). The in vivo studies showed good colon-targeting of HSS-DRM (T max = 0.97 h, C max = 118.28 µg/mL of HSS; T max = 2.16 h, C max = 64.47 µg/mL of HSS-DRM). Moreover, the HSS-DRM could reduce adverse reactions induced by HSS and had good therapeutic effects on the experimental colitis. The resin microcapsule system has good colon-targeting and can be used in the development of colon-targeting preparations.
Synovitis induced by joint lavage with hypertonic saline solutions in healthy dairy calves
Achard, Damien; Francoz, David; Desrochers, André; Girard, Christiane; Piché, Caroline
2012-01-01
The objective of this study was to evaluate the effect of a single joint lavage with 7.2% or 15% hypertonic saline solutions (HSS) on the tarsocrural joints of healthy calves. The tarsi of 10 calves were randomly lavaged with 7.2% HSS, 15% HSS, or isotonic saline. Synovial fluid samples were collected aseptically on days 1 (before joint lavage), 2, 3, 4, and 8 for complete cytological analysis. Lameness, joint swelling, and pain were recorded daily. Calves were euthanized on day 8 for gross and histological analyses of synovial membranes and articular cartilage. Synovitis was evaluated using a scoring system reflecting inflammatory changes in synovial membranes. Joints irrigated with HSS were more distended and painful compared with isotonic control joints. Swelling decreased consistently in the joints lavaged with 7.2% HSS, whereas it remained unchanged in joints lavaged with 15% HSS. Slight to moderate lameness was observed in the joints lavaged with 15% HSS. In comparison to isotonic saline joints, total protein concentration was significantly increased on day 2 and 3 for the joints lavaged with 7.2% HSS (P ≤ 0.01) and on days 2, 3, and 4 in the joints lavaged with 15% HSS (P ≤ 0.0006). Gross and histological findings revealed that synovitis was more severe in the joints lavaged with 15% HSS but variable in the joints lavaged with 7.2% HSS. No significant differences were observed for the articular cartilage. Fifteen percent HSS is not recommended for joint lavage. Although irrigation with 7.2% HSS may induce a variable synovitis, it was found appropriate for joint lavage. Its effects on septic joints remain undetermined. PMID:23024450
Li, Bing; Zhao, Haiyan; Liu, Jing; Liu, Wei; Fan, Sai; Wu, Guohua; Zhao, Rong
2015-12-18
A quick and simple ultra-high performance supercritical fluid chromatography-photodiode array detector method was developed and validated for the simultaneous determination of 9 carotenoids in dietary supplements. The influences of stationary phase, co-solvent, pressure, temperature and flow rate on the separation of carotenoids were evaluated. The separation of the carotenoids was carried out using an Acquity UPC(2) HSS C18 SB column (150mm×3.0mm, 1.8μm) by gradient elution with carbon dioxide and a 1:2 (v:v) methanol/ethanol mixture. The column temperature was set to 35°C and the backpressure was 15.2MPa. Under these conditions, 9 carotenoids and the internal standard, β-apo-8'-carotenal, were successfully separated within 10min. The correlation coefficients (R(2)) of the calibration curves were all above 0.997, the limits of detection for the 9 carotenoids were in the range of 0.33-1.08μg/mL, and the limits of quantification were in the range of 1.09-3.58μg/mL. The mean recoveries were from 93.4% to 109.5% at different spiking levels, and the relative standard deviations were between 0.8% and 6.0%. This method was successfully applied to the determination of 9 carotenoids in commercial dietary supplements. Copyright © 2015 Elsevier B.V. All rights reserved.
Bonaccorsi, Ivana; Cacciola, Francesco; Utczas, Margita; Inferrera, Veronica; Giuffrida, Daniele; Donato, Paola; Dugo, Paola; Mondello, Luigi
2016-09-01
Offline multidimensional supercritical fluid chromatography combined with reversed-phase liquid chromatography was employed for the carotenoid and chlorophyll characterization in different sweet bell peppers (Capsicum annuum L.) for the first time. The first dimension consisted of an Acquity HSS C18 SB (100 × 3 mm id, 1.8 μm particles) column operated with a supercritical mobile phase in an ultra-performance convergence chromatography system, whereas the second dimension was performed in reversed-phase mode with a C30 (250 × 4.6 mm id, 3.0 μm particles) stationary phase combined with photodiode array and mass spectrometry detection. This approach allowed the determination of 115 different compounds belonging to chlorophylls, free xanthophylls, free carotenes, xanthophyll monoesters, and xanthophyll diesters, and proved to be a significant improvement in the pigments determination compared to the conventional one-dimensional liquid chromatography approach so far applied to the carotenoid analysis in the studied species. Moreover, the present study also aimed to investigate and to compare the carotenoid stability and composition in overripe yellow and red bell peppers collected directly from the plant, thus also evaluating whether biochemical changes are linked to carotenoid degradation in the nonclimacteric investigated fruits, for the first time. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Meijun; Shi, Dongbo
2017-01-01
Humanities and Social Sciences (HSS) increasingly absorb knowledge from Hard Sciences, i.e., Science, Technology, Agriculture and Medicine (STAM), as testified by a growing number of citations. However, whether citing more Hard Sciences brings more citations to HSS remains to be investigated. Based on China’s HSS articles indexed by the Web of Science during 1998–2014, this paper estimated two-way fixed effects negative binomial models, with journal effects and year effects. Findings include: (1) An inverse U-shaped curve was observed between the percentage of STAM references to the HSS articles and the number of citations they received; (2) STAM contributed increasing knowledge to China’s HSS, while Science and Technology knowledge contributed more citations to HSS articles. It is recommended that research policy should be adjusted to encourage HSS researchers to adequately integrate STAM knowledge when conducting interdisciplinary research, as over-cited STAM knowledge may jeopardize the readability of HSS articles. PMID:28934277
Liu, Meijun; Shi, Dongbo; Li, Jiang
2017-01-01
Humanities and Social Sciences (HSS) increasingly absorb knowledge from Hard Sciences, i.e., Science, Technology, Agriculture and Medicine (STAM), as testified by a growing number of citations. However, whether citing more Hard Sciences brings more citations to HSS remains to be investigated. Based on China's HSS articles indexed by the Web of Science during 1998-2014, this paper estimated two-way fixed effects negative binomial models, with journal effects and year effects. Findings include: (1) An inverse U-shaped curve was observed between the percentage of STAM references to the HSS articles and the number of citations they received; (2) STAM contributed increasing knowledge to China's HSS, while Science and Technology knowledge contributed more citations to HSS articles. It is recommended that research policy should be adjusted to encourage HSS researchers to adequately integrate STAM knowledge when conducting interdisciplinary research, as over-cited STAM knowledge may jeopardize the readability of HSS articles.
Health systems strengthening: a common classification and framework for investment analysis
Shakarishvili, George; Lansang, Mary Ann; Mitta, Vinod; Bornemisza, Olga; Blakley, Matthew; Kley, Nicole; Burgess, Craig; Atun, Rifat
2011-01-01
Significant scale-up of donors’ investments in health systems strengthening (HSS), and the increased application of harmonization mechanisms for jointly channelling donor resources in countries, necessitate the development of a common framework for tracking donors’ HSS expenditures. Such a framework would make it possible to comparatively analyse donors’ contributions to strengthening specific aspects of countries’ health systems in multi-donor-supported HSS environments. Four pre-requisite factors are required for developing such a framework: (i) harmonization of conceptual and operational understanding of what constitutes HSS; (ii) development of a common set of criteria to define health expenditures as contributors to HSS; (iii) development of a common HSS classification system; and (iv) harmonization of HSS programmatic and financial data to allow for inter-agency comparative analyses. Building on the analysis of these aspects, the paper proposes a framework for tracking donors’ investments in HSS, as a departure point for further discussions aimed at developing a commonly agreed approach. Comparative analysis of financial allocations by the Global Fund to Fight AIDS, Tuberculosis and Malaria and the GAVI Alliance for HSS, as an illustrative example of applying the proposed framework in practice, is also presented. PMID:20952397
Niemüller, Daniel; Reimann, Andreas; Ober, Dietrich
2012-07-01
Homospermidine synthase (HSS) is the first specific enzyme in pyrrolizidine alkaloid (PA) biosynthesis, a pathway involved in the plant's chemical defense. HSS has been shown to be recruited repeatedly by duplication of a gene involved in primary metabolism. Within the lineage of the Boraginales, only one gene duplication event gave rise to HSS. Here, we demonstrate that the tissue-specific expression of HSS in three boraginaceous species, Heliotropium indicum, Symphytum officinale, and Cynoglossum officinale, is unique with respect to plant organ, tissue, and cell type. Within H. indicum, HSS is expressed exclusively in nonspecialized cells of the lower epidermis of young leaves and shoots. In S. officinale, HSS expression has been detected in the cells of the root endodermis and in leaves directly underneath developing inflorescences. In young roots of C. officinale, HSS is detected only in cells of the endodermis, but in a later developmental stage, additionally in the pericycle. The individual expression patterns are compared with those within the Senecioneae lineage (Asteraceae), where HSS expression is reproducibly found in specific cells of the endodermis and the adjacent cortex parenchyma of the roots. The individual expression patterns within the Boraginales species are discussed as being a requirement for the successful recruitment of HSS after gene duplication. The diversity of HSS expression within this lineage adds a further facet to the already diverse patterns of expression that have been observed for HSS in other PA-producing plant lineages, making this PA-specific enzyme one of the most diverse expressed proteins described in the literature.
Niemüller, Daniel; Reimann, Andreas; Ober, Dietrich
2012-01-01
Homospermidine synthase (HSS) is the first specific enzyme in pyrrolizidine alkaloid (PA) biosynthesis, a pathway involved in the plant’s chemical defense. HSS has been shown to be recruited repeatedly by duplication of a gene involved in primary metabolism. Within the lineage of the Boraginales, only one gene duplication event gave rise to HSS. Here, we demonstrate that the tissue-specific expression of HSS in three boraginaceous species, Heliotropium indicum, Symphytum officinale, and Cynoglossum officinale, is unique with respect to plant organ, tissue, and cell type. Within H. indicum, HSS is expressed exclusively in nonspecialized cells of the lower epidermis of young leaves and shoots. In S. officinale, HSS expression has been detected in the cells of the root endodermis and in leaves directly underneath developing inflorescences. In young roots of C. officinale, HSS is detected only in cells of the endodermis, but in a later developmental stage, additionally in the pericycle. The individual expression patterns are compared with those within the Senecioneae lineage (Asteraceae), where HSS expression is reproducibly found in specific cells of the endodermis and the adjacent cortex parenchyma of the roots. The individual expression patterns within the Boraginales species are discussed as being a requirement for the successful recruitment of HSS after gene duplication. The diversity of HSS expression within this lineage adds a further facet to the already diverse patterns of expression that have been observed for HSS in other PA-producing plant lineages, making this PA-specific enzyme one of the most diverse expressed proteins described in the literature. PMID:22566491
Yu, Mingming; Hassan, Hazem E; Ibrahim, Ahmed; Bauer, Kenneth S; Kelly, Deanna L; Wang, Jia Bei
2014-08-15
Currently, there are no FDA approved medications for treatment of cocaine addiction underscoring the dire need to develop such a product. There is an accumulating body of evidence that l-tetrahydropalmatine (l-THP), a non-selective dopamine antagonist, can be used for the treatment of cocaine addiction. Indeed, the FDA recently approved its usage in a Phase I study in cocaine abusers and it was indispensable to develop a simple and sensitive method for the simultaneous determination of l-THP and cocaine in human plasma. We developed a UPLC-FLD method for quantitation of these molecules using an ACQUITY BEH C18 column (2.1 mm × 50mm, 1.7 μm) and a mobile phase that consisted of 10mM ammonium phosphate (pH=4.75), methanol, and acetonitrile (v:v:v, 78:16:6). Venlafaxine was used as the internal standard while hexane was used for the liquid-liquid extraction. The flow rate was 0.4 mL/min with fluorescence detection using an excitation wavelength of 230 nm and emission detection wavelength of 315 nm. This method was selective, linear and sensitive with a lower limit of quantification of 2.5 ng/mL for both cocaine and l-THP. The intra-day precision of cocaine and l-THP was <9.50% while the accuracy was <4.29%. The inter-day precision of cocaine and l-THP was <9.14%, and the accuracy was <12.49%. The recovery for cocaine and l-THP ranged from 43.95 to 50.02% and 54.65 to 58.31%, respectively. In comparison to forty reported cocaine quantitation methods this method is simple, sensitive and cost-effective and can be used for simultaneous quantitation of l-THP and cocaine. This method meets the FDA guidelines and can be used in current and future clinical studies. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhao, Yu; Zhao, Min; Jiang, Qi; Qin, Feng; Wang, Chengying; Xiong, Zhili; Wang, Shaojie; He, Zhonggui; Guo, Xingjie; Zhao, Longshan
2018-06-02
MP3950 is being developed as a gastroprokinetic candidate compound. To illustrate the pharmacokinetic profiles, absolute bioavailability after intravenous administration and oral administration with MP3950 as well as tissue distribution in vivo, an UPLC-MS/MS approach which was rapid and selective was developed to determine MP3950 in plasma and tissue of rat. Sample pre-treatment of plasma sample was one-step protein precipitation. 0.1% formic acid containing 5 mmol/L ammonium acetate-methanol(55/45,v/v) was used for isocratic elution on a Waters ACQUITY UPLC® BEH C18 (50 mm × 2.1 mm, 1.7 μm) to achieve the separation. The analysis was performed in MRM mode via positive ESI mode. LLOQ of the method was 10 ng/mL, and the linearity up to 10,000 ng/mL. The intra-day precision (relative standard deviation, RSD) was 4.0-9.0% and the inter-day precision was 4.2-10.6%. The accuracy (relative error, RE) was -1.2-2.4%. Tissue samples were collected from the brain, heart, liver, spleen, lung, kidney, stomach, duodenum, small intestine, large intestine, appendix and skeletal muscle. The same liquid chromatographic and mass spectrometric conditions were used, and it's proven that this method was feasible to analyze the MP3950 in tissues with good precision and accuracy over the range from 10 to 5000 ng·mL -1 . It was found that the concentration of MP3950 is higher in digestive system. The tissue distribution, pharmacokinetic and bioavailability of MP3950 in rats were carried out by the method for the first time, which can provide enough information for the further development and investigation of MP3950. Copyright © 2018. Published by Elsevier B.V.
Kumar, Manoj; Sharma, Gaurav; Singla, Dinesh; Singh, Sukhjeet; Sahwney, Sudhir; Chauhan, Anurag S; Singh, Gagandeep; Kaur, Indu Pal
2014-03-01
A sensitive ultra-performance liquid chromatography (UPLC) method was developed for simultaneous estimation of all-trans retinoic acid (ATRA) and cholecalciferol (vitamin D3) in rat plasma. The method was validated over the linear range of 1.0-5000ng/ml (r(2)=0.999) for both vitamins with a limit of detection of 0.5ng/ml. Chromatographic separation was achieved using liquid-liquid extraction (LLE) on an Acquity BEH RP 18 column (2.1mm×50mm, I.D. 1.7μm), with mobile phase comprising of acetonitrile:methanol:water (90:8:2, v/v/v), at a flow rate of 0.20ml/min and a total run time of 5min. Intra and inter-day variability (RSD) was ≤3.1%, and the accuracy varied between 95.4-99.9% and 95.3-101.1% respectively, for ATRA and 98.5-100.8% and 99.3-101.7%, respectively for vitamin D3. High recovery of ≥96.0% for ATRA and ≥87.80% for vitamin D3 was achieved. ATRA and vitamin D3 were stable in plasma under different storage and processing conditions. The method was applied to estimate the total drug content and entrapment efficiency of ATRA and vitamin D3 loaded solid lipid nanoparticles (SLNs). Concentration of these two agents was determined in rat plasma after simultaneous subcutaneous administration in free form or when loaded into SLNs thus establishing pharmacokinetic application of the developed procedure. Results indicated an improvement in AUC0-∞ by 5.4 times and 29.4 times for ATRA and vitamin D3, respectively, upon their incorporation into SLNs. Simultaneous administration of these two vitamins and their improved and prolonged bioavailability has scope for their use in treatment and control of tuberculosis. Copyright © 2014 Elsevier B.V. All rights reserved.
Tsai, Feng-Jen; Lee, Howard; Fan, Victoria Y
2016-07-01
This paper aimed to compare the health systems strengthening (HSS) framework of Gavi and WHO and to analyze resource allocation in HSS by Gavi. Among 76 countries which received HSS funding from Gavi from 2006 to 2013, summary reports of 44 countries and approved proposals of 10 countries were collected. After comparing the HSS framework of WHO and Gavi, each activity described in documents was categorized according to Gavi's framework and funding allocation was analyzed. Compared with WHO's HSS framework, Gavi's has a distinctive function within the building block 'Drugs, Equipment, Supplies, Facilities' and a distinctive function of 'providing incentive and bonuses' under the building block 'Human Resource/Performance Management'. Gavi has steadily invested 10% of their total budget on HSS, but 47% were allocated in these categories, whereas 78% were for activities arguably not covered by WHO's HSS framework. In Africa, 70% of Gavi's budget fell under 'Drugs, Equipment, Supplies, Facilities' and 92.8% were for activities arguably not deemed as HSS by WHO. Gavi's HSS support emphasized inputs with short-term measurable outcomes. Harmonization of the concept of HSS and collaboration between Gavi and multilateral international agencies, such as World Bank and WHO, are needed. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Complete temperature profiles in ultra-high-pressure liquid chromatography columns.
Gritti, Fabrice; Guiochon, Georges
2008-07-01
The temperature profiles were calculated along and across seven packed columns (lengths 30, 50, 100, and 150 mm, i.d., 1 and 2.1 mm, all packed with Acquity UPLC, BEH-C 18 particles, average d(p) approximately 1.7 microm) and their stainless steel tubes (o.d. 4.53 and 6.35 mm). These columns were kept horizontal and sheltered from forced air convection (i.e., under still air conditions), at room temperature. They were all percolated with pure acetonitrile, either under the maximum pressure drop (1034 bar) or at the maximum flow rate (2 mL/min) permitted by the chromatograph. The heat balance equation of chromatographic columns was discretized and solved numerically with minimum approximation. Both the compressibility and the thermal expansion of the eluent were taken into account. The boundary conditions were determined from the experimental measurements of the column inlet pressure and of the temperature profile along the column wall, which were made with a precision better than +/-0.1 K. These calculation results provide the 3-D temperature profiles along and across the columns. The axial and radial temperature gradients are discussed in relationship with the experimental conditions used. The temperature map obtained permits a prediction of the chromatographic data obtained under a very high pressure gradient.
Chandra, Preeti; Kannujia, Rekha; Saxena, Ankita; Srivastava, Mukesh; Bahadur, Lal; Pal, Mahesh; Singh, Bhim Pratap; Kumar Ojha, Sanjeev; Kumar, Brijesh
2016-09-10
An ultra-high performance liquid chromatography electrospray ionization tandem mass spectrometry method has been developed and validated for simultaneous quantification of six major bioactive compounds in five varieties of Withania somnifera in various plant parts (leaf, stem and root). The analysis was accomplished on Waters ACQUITY UPLC BEH C18 column with linear gradient elution of water/formic acid (0.1%) and acetonitrile at a flow rate of 0.3mLmin(-1). The proposed method was validated with acceptable linearity (r(2), 0.9989-0.9998), precision (RSD, 0.16-2.01%), stability (RSD, 1.04-1.62%) and recovery (RSD ≤2.45%), under optimum conditions. The method was also successfully applied for the simultaneous determination of six marker compounds in twenty-six marketed formulations. Hierarchical cluster analysis and principal component analysis were applied to discriminate these twenty-six batches based on characteristics of the bioactive compounds. The results indicated that this method is advance, rapid, sensitive and suitable to reveal the quality of Withania somnifera and also capable of performing quality evaluation of polyherbal formulations having similar markers/raw herbs. Copyright © 2016 Elsevier B.V. All rights reserved.
GBF-dependent family genes morphologically suppress the partially active Dictyostelium STATa strain.
Shimada, Nao; Kanno-Tanabe, Naoko; Minemura, Kakeru; Kawata, Takefumi
2008-02-01
Transcription factor Dd-STATa, a functional Dictyostelium homologue of metazoan signal transducers and activators of transcription proteins, is necessary for culmination during development. We have isolated more than 18 putative multicopy suppressors of Dd-STATa using genetic screening. One was hssA gene, whose expression is known to be G-box-binding-factor-dependent and which was specific to prestalk A (pstA) cells, where Dd-STATa is activated. Also, hssA mRNA was expressed in pstA cells in the Dd-STATa-null mutant. At least 40 hssA-related genes are present in the genome and constitute a multigene family. The tagged HssA protein was translated; hssA encodes an unusually high-glycine-serine-rich small protein (8.37 kDa), which has strong homology to previously reported cyclic-adenosine-monophosphate-inducible 2C and 7E proteins. Overexpression of hssA mRNA as well as frame-shifted versions of hssA RNA suppressed the phenotype of the partially active Dd-STATa strain, suggesting that translation is not necessary for suppression. Although overexpression of prespore-specific genes among the family did not suppress the parental phenotype, prestalk-specific family members did. Although overexpression of the hssA did not revert the expression of Dd-STATa target genes, and although its suppression mechanism remains unknown, morphological reversion implies functional relationships between Dd-STATa and hssA.
Krossa, Sebastian; Faust, Annette; Ober, Dietrich; Scheidig, Axel J.
2016-01-01
The highly conserved bacterial homospermidine synthase (HSS) is a key enzyme of the polyamine metabolism of many proteobacteria including pathogenic strains such as Legionella pneumophila and Pseudomonas aeruginosa; The unique usage of NAD(H) as a prosthetic group is a common feature of bacterial HSS, eukaryotic HSS and deoxyhypusine synthase (DHS). The structure of the bacterial enzyme does not possess a lysine residue in the active center and thus does not form an enzyme-substrate Schiff base intermediate as observed for the DHS. In contrast to the DHS the active site is not formed by the interface of two subunits but resides within one subunit of the bacterial HSS. Crystal structures of Blastochloris viridis HSS (BvHSS) reveal two distinct substrate binding sites, one of which is highly specific for putrescine. BvHSS features a side pocket in the direct vicinity of the active site formed by conserved amino acids and a potential substrate discrimination, guiding, and sensing mechanism. The proposed reaction steps for the catalysis of BvHSS emphasize cation-π interaction through a conserved Trp residue as a key stabilizer of high energetic transition states. PMID:26776105
2011-01-01
Hughes-Stovin Syndrome (HSS) is a very rare clinical disorder characterized by thrombophlebitis and multiple pulmonary and/or bronchial aneurysms. Less than 40 published cases of HSS have been described in English medical literature so far. The exact etiology and pathogenesis of HSS is unknown; possible causes include infections and angiodysplasia. HSS has also been considered as a variant of Behcet's disease (BD). Patients with HSS usually present with cough, dyspnea, fever, chest pain and haemoptysis. The management of HSS can either be medical or surgical. Medical management includes the use of steroids and cytotoxic agents. Cyclophosphamide, in particular, is a favored therapeutic agent in this regard. Antibiotics have no proven role in HSS while anticoagulants and thombolytic agents are generally contraindicated due to an increased risk of fatal hemorrhage. However, their use may be considered with great care under special circumstances, for instance, intracardiac thrombi or massive pulmonary embolism. For cases of massive hemoptysis due to large pulmonary aneurysms or those with lesions confined to one segment or one lung, lobectomy or pneumectomy can be carried out. However, surgical risks merit serious consideration and must be discussed with the patient. Transcatheter arterial embolization has emerged as a less invasive alternative to surgery in selected cases of HSS. Overall, patients with HSS have a poor prognosis and aneurysmal rupture is the leading cause of death. However, early diagnosis and timely intervention is crucial in improving the prognosis. There is a need to clearly elucidate the genetic, etiologic and pathologic basis for HSS in the future. Although most of the evidence put forward to refute the role of an infectious agent in the etiology and pathogenesis of HSS is based on negative blood and other body fluid cultures, more robust objective assessment is needed through the use of electron microscopy or 16 sRNA studies. The development of better therapeutic agents is also needed to address and prevent the serious consequences arising from pulmonary arterial aneurysms seen in BD and HSS. Also, the issue of anticoagulation in these patients is challenging and requires further deliberation. PMID:21489283
NASA Astrophysics Data System (ADS)
Darmawan, B.; Kusman, M.; Hamdani, R. A.
2016-04-01
The study aims to compare the performance of two types of material HSS (High Speed Steel) are widely used. It also will be the chemical composition and distribution of carbide particles therein. Two types of HSS are available in the market: HSS from Germany (Bohler) and HSS from China. This research employed the pure experimental design. It consists of two stages. The first, aims to test/operate lathe machines to determine the lifetime and performance of tools based on specified wear criteria. The second, characterization of microstructure using SEM-EDS was conducted. Firstly, grinding of toolss was done so that the toolss could be used for cutting metal in the turning process. Grinding processes of the two types of toolss were done at the same geometry, that is side rake angle (12°-18°), angle of keenness (60°-68°), and side relief angle (10°-12°). Likewise, machining parameters were set in the same machining conditions. Based on the results of the tests, it is found that to reach 0.2 mm wear point, toolss made of HSS from Germany needed 24 minutes, while toolss made of HSS from China needed 8 minutes. Next, microstructure tests using SEM/EDS were done. The results of the SEM tests indicate that the carbide particles of HSS from Germany were more evenly distributed than the carbide particles of HSS from China. Carbide compounds identified in HSS from China were Cr23C6 and Fe4Mo2C. Oxide impurity of Al2O3 was also found in the material. On the other hand, in HSS from Germany, no impurity and other carbide compounds were identified, except Cr23C6 and Fe4Mo2C, also Fe4W2C, and VC or V4C3.
Mimche, Honoré; Squires, Ellen; Miangotar, Yodé; Mokdad, Ali; El Bcheraoui, Charbel
2018-05-01
Despite the increase in Health System Strengthening (HSS) grants, there is no consensus among global health actors about how to maximize the efficiency and sustainability of HSS programs and their resulting gains. To formally analyze and compare the efficiency and sustainability of Gavi's HSS grants, we investigated the factors, events and root causes that increased the time and effort needed to implement HSS grants, decreased expected outcomes and threatened the continuity of activities and the sustainability of the results gained through these grants in Cameron and Chad. We conducted 2 retrospective independent evaluations of Gavi's HSS support in Cameroon and Chad using a mixed methodology. We investigated the chain of events and situations that increased the effort and time required to implement the HSS programs, decreased the value of the funds spent and hindered the sustainability of the implemented activities and gains achieved. Root causes affecting the efficiency and sustainability of HSS grants were common to Cameroon and Chad. Weaknesses in health workforce and leadership/governance of the health system in both countries led to interrupting the HSS grants, reprogramming them, almost doubling their implementation period, shifting their focus during implementation toward procurements and service provision, leaving both countries without solid exit plans to maintain the results gained. To increase the efficiency and sustainability of Gavi's HSS grants, recipient countries need to consider health workforce and leadership/governance prior, or in parallel to strengthening other building blocks of their health systems.
Kaltenegger, Elisabeth; Eich, Eckart; Ober, Dietrich
2013-01-01
Homospermidine synthase (HSS), the first pathway-specific enzyme of pyrrolizidine alkaloid biosynthesis, is known to have its origin in the duplication of a gene encoding deoxyhypusine synthase. To study the processes that followed this gene duplication event and gave rise to HSS, we identified sequences encoding HSS and deoxyhypusine synthase from various species of the Convolvulaceae. We show that HSS evolved only once in this lineage. This duplication event was followed by several losses of a functional gene copy attributable to gene loss or pseudogenization. Statistical analyses of sequence data suggest that, in those lineages in which the gene copy was successfully recruited as HSS, the gene duplication event was followed by phases of various selection pressures, including purifying selection, relaxed functional constraints, and possibly positive Darwinian selection. Site-specific mutagenesis experiments have confirmed that the substitution of sites predicted to be under positive Darwinian selection is sufficient to convert a deoxyhypusine synthase into a HSS. In addition, analyses of transcript levels have shown that HSS and deoxyhypusine synthase have also diverged with respect to their regulation. The impact of protein–protein interaction on the evolution of HSS is discussed with respect to current models of enzyme evolution. PMID:23572540
Tyśkiewicz, Katarzyna; Gieysztor, Roman; Maziarczyk, Izabela; Hodurek, Paweł; Rój, Edward; Skalicka-Woźniak, Krystyna
2018-05-10
In the presented study for the first time a new, optimized, fast SFC (supercritical fluid chromatography) method was applied to separate in one run fat-soluble vitamins from waste fish oil, including cis -and tran s-retinyl palmitate, cis - and trans -retinyl acetate, retinol, α-tocopherol, β-tocopherol, γ‑tocopherol, δ-tocopherol, ergocalciferol (D₂), cholecalciferol (D₃), cis - and trans -phylloquinone (K₁) and menaquinone-4 (K₂-MK4). Vitamins were baseline separated on an Acquity UPC² (ultra performance convergence chromatography) HSS C18 SB (highly strength chemically modified silica) column within 13 min. The influence of the stationary phase, such as Torus 1-AA (1-aminoanthracene), Torus Diol (high density diol), Torus DEA (diethylamine), BEH (silica with no bonding), BEH-2EP (2-ethylpirydine), CSH Fluoro-Phenyl (silica with fluoro-phenyl groups), column temperature, flow rate and back pressure on the separation of the compounds was described. The application of the modified saponification procedure allowed us to increase concentration in the sample prepared for the analysis of γ‑tocopherol from less than 1% (wt %) to 14% for the first time. In addition, α‑tocopherol, γ‑tocopherol, δ‑tocopherol and retinol were identified in waste fish oil. Vitamin purification and analysis in waste fish oil are reported for the first time here. Due to the short time and effectiveness of the proposed method, it can be easily applied in industrial processes.
Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong
2017-01-01
Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time. PMID:28429740
NASA Astrophysics Data System (ADS)
Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong
2017-04-01
Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time.
Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong
2017-04-21
Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time.
Validity and Reliability of the Korean Version of the Hyperthyroidism Symptom Scale.
Lee, Jie Eun; Lee, Dong Hwa; Oh, Tae Jung; Kim, Kyoung Min; Choi, Sung Hee; Lim, Soo; Park, Young Joo; Park, Do Joon; Jang, Hak Chul; Moon, Jae Hoon
2018-03-01
Thyrotoxicosis is a common disease resulting from an excess of thyroid hormones, which affects many organ systems. The clinical symptoms and signs are relatively nonspecific and can vary depending on age, sex, comorbidities, and the duration and cause of the disease. Several symptom rating scales have been developed in an attempt to assess these symptoms objectively and have been applied to diagnosis or to evaluation of the response to treatment. The aim of this study was to assess the reliability and validity of the Korean version of the hyperthyroidism symptom scale (K-HSS). Twenty-eight thyrotoxic patients and 10 healthy subjects completed the K-HSS at baseline and after follow-up at Seoul National University Bundang Hospital. The correlation between K-HSS scores and thyroid function was analyzed. K-HSS scores were compared between baseline and follow-up in patient and control groups. Cronbach's α coefficient was calculated to demonstrate the internal consistency of K-HSS. The mean age of the participants was 34.7±9.8 years and 13 (34.2%) were men. K-HSS scores demonstrated a significant positive correlation with serum free thyroxine concentration and decreased significantly with improved thyroid function. K-HSS scores were highest in subclinically thyrotoxic subjects, lower in patients who were euthyroid after treatment, and lowest in the control group at follow-up, but these differences were not significant. Cronbach's α coefficient for the K-HSS was 0.86. The K-HSS is a reliable and valid instrument for evaluating symptoms of thyrotoxicosis in Korean patients. Copyright © 2018 Korean Endocrine Society.
Validity and Reliability of the Korean Version of the Hyperthyroidism Symptom Scale
Lee, Dong Hwa
2018-01-01
Background Thyrotoxicosis is a common disease resulting from an excess of thyroid hormones, which affects many organ systems. The clinical symptoms and signs are relatively nonspecific and can vary depending on age, sex, comorbidities, and the duration and cause of the disease. Several symptom rating scales have been developed in an attempt to assess these symptoms objectively and have been applied to diagnosis or to evaluation of the response to treatment. The aim of this study was to assess the reliability and validity of the Korean version of the hyperthyroidism symptom scale (K-HSS). Methods Twenty-eight thyrotoxic patients and 10 healthy subjects completed the K-HSS at baseline and after follow-up at Seoul National University Bundang Hospital. The correlation between K-HSS scores and thyroid function was analyzed. K-HSS scores were compared between baseline and follow-up in patient and control groups. Cronbach's α coefficient was calculated to demonstrate the internal consistency of K-HSS. Results The mean age of the participants was 34.7±9.8 years and 13 (34.2%) were men. K-HSS scores demonstrated a significant positive correlation with serum free thyroxine concentration and decreased significantly with improved thyroid function. K-HSS scores were highest in subclinically thyrotoxic subjects, lower in patients who were euthyroid after treatment, and lowest in the control group at follow-up, but these differences were not significant. Cronbach's α coefficient for the K-HSS was 0.86. Conclusion The K-HSS is a reliable and valid instrument for evaluating symptoms of thyrotoxicosis in Korean patients. PMID:29589389
Hypertonic Saline as a Useful Tool for Sputum Induction and Pathogen Detection in Cystic Fibrosis.
Ferreira, Adriana Carolina Marques; Marson, Fernando Augusto Lima; Cohen, Milena Antonelli; Bertuzzo, Carmen Silvia; Levy, Carlos Emilio; Ribeiro, Antonio Fernando; Ribeiro, Jose Dirceu
2017-08-01
The aim of this study was to compare the qualitative and semi-quantitative detection of pathogens in the airway secretions of patients with cystic fibrosis (CF) and the sputum induction capacity before and after inhalation of 7% hypertonic saline solution (HSS). The study enrolled 64 patients with CF. Airway secretions were collected from all enrolled patients with CF before and after inhalation of 7% HSS, and the samples were screened for pathogens. Inhalation of 7% HSS increased the probability of producing sputum from 36 to 52% (p = 0.002) in children with CF. The effect was most in children under 11 years. Inhalation of 7% HSS improved qualitative pathogen identification (p = 0.008). Inhalation of 7% HSS increased the mucoid Pseudomonas aeruginosa (p = 0.002) and non-mucoid P. aeruginosa in the semi-quantitative analysis (p = 0.035). Four new pathogens (Aspergillus fumigatus, Achromobacter xylosoxidans, Ochrobactrum anthropi, and Elizabethkingia meningoseptica) were identified in the sputum samples collected from the airways of patients with CF following 7% HSS. Inhalation of 7% HSS increased sputum production and pathogen identification in children with CF. The inhalation of 7% HSS was feasible and should be implemented for routine pathogen detection in the airways of patients with CF, particularly in those patients who do not produce sputum.
Renal function in hepatosplenic schistosomiasis--an assessment of renal tubular disorders.
Duarte, Daniella Bezerra; Vanderlei, Lucas Alexandre; Bispo, Raianne Kívia de Azevêdo; Pinheiro, Maria Eliete; da Silva, Geraldo Bezerra; Martins, Alice Maria Costa; Meneses, Gdayllon Cavalcante; Daher, Elizabeth De Francesco
2014-01-01
Renal involvement in Schistosoma mansoni infection is not well studied. The aim of this study is to investigate the occurrence of renal abnormalities in patients with hepatosplenic schistosomiasis (HSS), especially renal tubular disorders. This is a cross-sectional study with 20 consecutive patients with HSS followed in a medical center in Maceió, Alagoas, Brazil. Urinary acidification and concentration tests were performed using calcium chloride (CaCl2) after a 12-h period of water and food deprivation. The biomarker monocyte chemoattractant protein 1 (MCP-1) was quantified in urine. Fractional excretion of sodium (FENa+), transtubular potassium gradient (TTKG) and solute-free water reabsorption (TcH2O) were calculated. The HSS group was compared to a group of 17 healthy volunteers. Patients' mean age and gender were similar to controls. Urinary acidification deficit was found in 45% of HSS patients. Urinary osmolality was significantly lower in HSS patients (588 ± 112 vs. 764 ± 165 mOsm/kg, p = 0,001) after a 12-h period of water deprivation. TcH2O was lower in HSS patients (0.72 ± 0.5 vs. 1.1 ± 0.3, p = 0.04). Urinary concentration deficit was found in 85% of HSS patients. The values of MCP-1 were higher in HSS group than in control group (122 ± 134 vs. 40 ± 28 pg/mg-Cr, p = 0.01) and positively correlated with the values of microalbuminuria and proteinuria. HSS is associated with important kidney dysfunction. The main abnormalities found were urinary concentrating ability and incomplete distal acidification defect, demonstrating the occurrence of tubular dysfunction. There was also an increase in urinary MCP-1, which appears to be a more sensitive marker of renal damage than urinary albumin excretion rate.
Maruhashi, Tatsuya; Iwamoto, Yumiko; Kajikawa, Masato; Oda, Nozomu; Kishimoto, Shinji; Matsui, Shogo; Hashimoto, Haruki; Aibara, Yoshiki; Yusoff, Farina Mohamad; Hidaka, Takayuki; Kihara, Yasuki; Chayama, Kazuaki; Noma, Kensuke; Nakashima, Ayumu; Goto, Chikara; Hida, Eisuke; Higashi, Yukihito
2017-12-29
Flow-mediated vasodilation (FMD) of the brachial artery has been used for the assessment of endothelial function. Considering the mechanism underlying the vasodilatory response of the brachial artery to reactive hyperemia, hyperemic shear stress (HSS), a stimulus for FMD; nitroglycerine-induced vasodilation (NID), an index of endothelium-independent vasodilation; and baseline brachial artery diameter (BAD) are also involved in vasodilatory response. The purpose of this study was to investigate the interrelationships among FMD, HSS, NID, baseline BAD, and cardiovascular risk factors. We measured FMD, HSS, NID, and baseline BAD simultaneously in 1033 participants (633 men and 400 women; mean age: 58.6±17.0 years). Framingham risk score was negatively correlated with FMD, HSS, and NID and was positively correlated with baseline BAD. HSS and NID were positively correlated with FMD, and baseline BAD was negatively correlated with FMD. In participants with normal NID, FMD was correlated with HSS, NID, and baseline BAD, all of which were independent variables of FMD in multivariate analysis. In participants with impaired NID, FMD was correlated with NID and baseline BAD, both of which were independent variables of FMD in multivariate analysis, but there was no association between FMD and HSS. NID and baseline BAD were independent variables of FMD regardless of the status of endothelium-independent vasodilation, whereas there was a significant association between FMD and HSS in participants with normal NID but not in those with impaired NID. The influence of HSS on FMD seems to be dependent on the status of endothelium-independent vasodilation. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.
Walsh, Danielle S; Lazorick, Suzanne; Lawson, Luan; Lake, Donna; Garrison, Herbert G; Higginson, Jason; Vos, Paul; Baxley, Elizabeth
2018-05-01
This project aimed to evaluate the effectiveness of a faculty development program in health systems science (HSS)-the Teachers of Quality Academy (TQA). Participants in TQA and a comparison group were evaluated before, during, and 1 year after the program using self-perception questionnaires, tests of HSS knowledge, and tracking of academic productivity and career advancement. Among program completers (n = 27), the mean self-assessed ratings of knowledge and skills of HSS topics immediately after the program, as compared to baseline, increased significantly compared to controls (n = 30). Participants demonstrated progressive improvement of self-perceived skills and attitudes, and retention of HSS knowledge, from baseline to completion of the program. Participants also demonstrated substantially higher HSS scholarly productivity, leadership, and career advancement compared to the comparison group. The TQA effectively created a faculty cadre able to role model, teach, and create a curriculum in HSS competencies for medical students, resident physicians, and other health professionals.
Concerns and Responses for Integrating Health Systems Science Into Medical Education.
Gonzalo, Jed D; Caverzagie, Kelly J; Hawkins, Richard E; Lawson, Luan; Wolpaw, Daniel R; Chang, Anna
2018-06-01
With the aim of improving the health of individuals and populations, medical schools are transforming curricula to ensure physician competence encompasses health systems science (HSS), which includes population health, health policy, high-value care, interprofessional teamwork, leadership, quality improvement, and patient safety. Large-scale, meaningful integration remains limited, however, and a major challenge in HSS curricular transformation efforts relates to the receptivity and engagement of students, educators, clinicians, scientists, and health system leaders. The authors identify several widely perceived challenges to integrating HSS into medical school curricula, respond to each concern, and provide potential strategies to address these concerns, based on their experiences designing and integrating HSS curricula. They identify two broad categories of concerns: the (1) relevance and importance of learning HSS-including the perception that there is inadequate urgency for change; HSS education is too complex and should occur in later years; early students would not be able to contribute, and the roles already exist; and the science is too nascent-and (2) logistics and practicality of teaching HSS-including limited curricular time, scarcity of faculty educators with expertise, lack of support from accreditation agencies and licensing boards, and unpreparedness of evolving health care systems to partner with schools with HSS curricula. The authors recommend the initiation and continuation of discussions between educators, clinicians, basic science faculty, health system leaders, and accrediting and regulatory bodies about the goals and priorities of medical education, as well as about the need to collaborate on new methods of education to reach these goals.
Jiang, Shu-Jun; Li, Wen
2013-01-01
Abstract Hepatic stimulator substance (HSS) has been suggested to protect liver cells from various toxins. However, the precise role of HSS in hepatic ischemia–reperfusion (I/R) injury remains unknown. This study aims to elucidate whether overexpression of HSS could attenuate hepatic ischemia–reperfusion injury and its possible mechanisms. Both in vivo hepatic I/R injury in mice and in vitro hypoxia–reoxygenation (H/R) in a cell model were used to evaluate the effect of HSS protection after adenoviral gene transfer. Moreover, a possible mitochondrial mechanism of HSS protection was investigated. Efficient transfer of the HSS gene into liver inhibited hepatic I/R injury in mice, as evidenced by improvement in liver function tests, the preservation of hepatic morphology, and a reduction in hepatocyte apoptosis. HSS overexpression also inhibited H/R-induced cell death, as detected by cell viability and cell apoptosis assays. The underlying mechanism of this hepatic protection might involve the attenuation of mitochondrial dysfunction and mitochondrial-dependent cell apoptosis, as shown by the good preservation of mitochondrial ultrastructure, mitochondrial membrane potential, and the inhibition of cytochrome c leakage and caspase activity. Moreover, the suppression of H/R-induced mitochondrial ROS production and the maintenance of mitochondrial respiratory chain complex activities may participate in this mechanism. This new function of HSS expands the possibility of its application for the prevention of I/R injury, such as hepatic resection and liver transplantation in clinical practice. PMID:23461564
Rong, Lili; Wu, Xiaohu; Xu, Jun; Dong, Fengshou; Liu, Xingang; Pan, Xinglu; Du, Pengqiang; Wei, Dongmei; Zheng, Yongquan
2018-02-01
We have developed a rapid, multi-compound analytical method for measuring residues of the pesticides thiamethoxam and its metabolite, clothianidin; fipronil and its three metabolites, fipronil sulfone, fipronil sulfide, and fipronil desulfinyl; and pyraclostrobin in unprocessed foods (rice, corn, cucumbers, tomatoes, apples, and bananas) by ultra-performance liquid chromatography coupled to tandem mass spectrometry. Acetonitrile was used as the extraction solvent, and an octadecylsilane-dispersive SPE was used to clean up the analytes, which were then separated through a UPLC HSS T3 column connected to a tandem mass spectrometer via an electrospray ionisation source. The linearity of this method for the target analytes was excellent (R 2 ≥0.990) in the concentration range of 5-1000 μg kg -1 . The average recoveries of the seven compounds at concentrations of 10, 100, and 1000 μg kg -1 from six spiked matrix samples ranged from 73.6 to 110.6%, all with RSD values of ≤19.7%. The limit of quantification was 10 μg kg -1 . The method validated the effectiveness of the method for routine monitoring the residue of these pesticides and their metabolites in foods.
Synthesis of nano grade hollow silica sphere via a soft template method.
Tsai, Ming-Shyong; Li, Miao Ju; Yen, Fu-Hsu
2008-06-01
The nano grade hollow silica sphere (HSS) was synthesized by a novel soft template method. We found that the precipitate of aluminate had a porous structure that could be the soft template for HSS. After mixing the colloidal silica with the aluminate precipitate, the bubble trapped in this porous structure could form the nano grade HSS. The aluminate precipitate was removed by adjusting the pH of the slurry to approximately 1. The outside diameter, the specific surface, and the mean pore size diameter of the forming HSS were 60-90 nm, 571 m2/g, and 3 nm, respectively. The formed HSS was collected by modifying the surface with Si(OCH3)3CHCH2 (VTMO) and then filtrating the precipitated gel in the n-butanol and ethanol solvent system.
Pandey, Renu; Chandra, Preeti; Arya, Kamal Ram; Kumar, Brijesh
2014-12-01
A rapid and sensitive ultra high performance liquid chromatography electrospray ionization tandem mass spectrometry method was developed and validated for the simultaneous determination of 13 flavonoids in leaf, stem, and fruit extracts of male and female trees of Ginkgo biloba to investigate gender- and age-related variations of flavonoids content. Chromatographic separation was accomplished on an Acquity UPLC BEH C18 column (50 mm × 2.1 mm id, 1.7 μm) in 5 min. Quantitation was performed using negative electrospray ionization mass spectrometry in multiple reaction monitoring mode. The calibration curves of all analytes showed a good linear relationship (r(2) ≥ 0.9977) over the concentration range of 1-1000 ng/mL. The precision evaluated by an intra- and interday study showed RSD ≤ 1.98% and good accuracy with overall recovery in the range from 97.90 to 101.09% (RSD ≤ 1.67%) for all analytes. The method sensitivity expressed as the limit of quantitation was typically 0.25-3.57 ng/mL. The results showed that the total content of 13 flavonoids was higher in the leaf extract of an old male Ginkgo tree compared to young female Ginkgo trees. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Lech, Rodziewicz; Jolanta, MasŁOwiecka; Anna, Sadowska; Halina, Car
2017-10-08
Five thyreostats (TSs), namely tapazole, thiouracil, methylthiouracil, propylthiouracil, and phenylthiouracil, were determined in bovine urine using ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) in positive electrospray ionization mode. Extraction and clean-up were achieved using a ChemElut cartridge with tert -butyl methyl ether, without a derivatization step. Separation was achieved on an Acquity UPLC SS T3 column. The mobile phase was acetonitrile and water containing 0.2% (v/v) formic acid. The mass spectrometer was operated in multiple reaction monitoring mode. Urine samples were spiked with TS solution at levels corresponding to 5, 10, 15, and 20 μg/L. The accuracy (internal standard corrected) ranged from 92% to 107%, with a repeatability precision (relative standard deviation, RSD) less than 15% for all five analytes. The RSDs within-laboratory reproducibility was less than 26%. The decision limits (CCα) and detection capabilities (CCβ) were obtained from a calibration curve and were in the ranges of 3.1-6.1 μg/L and 4.0-7.4 μg/L, respectively. The CCα and CCβ values were below the recommended concentration, which was set at 10 μg/L. The results show that the described method is suitable for the direct detection of TSs in bovine urine. This method can also be used to determine TSs in porcine urine.
Li, Guang-Yao; Zhang, Li; Liu, Ji-Zhu; Chen, Shou-Guo; Xiao, Tai-Wu; Liu, Guo-Zhen; Wang, Jing-Xia; Wang, Le-Xin; Hou, Ming
2016-07-01
Pharmacological management of acute leukemia remains a challenge. A seashell protein Haishengsu (HSS) has been found to exert anticancer activities in recent in vitro studies. The aim of this study was to determine whether the addition of HSS to the conventional chemotherapies would increase chemosensitivity and improves quality of life in patients with acute leukemia. Two hundred and forty-eight patients with acute leukemia were enrolled in a double-blind, and placebo-controlled study. In addition to conventional chemotherapy, 142 patients received HSS and 106 received placebo. In an in vitro study, the expression of P-gp was evaluated by flow cytometry in a drug-resistant leukemia cell line (K562/ADM cells). Sorcin was examined by Western blot. The complete remission rates in the HSS treatment group were all higher than in the placebo group with non-relapsing leukemia and relapsed leukemia (p<0.05). Less patients in the HSS group experienced gastrointestinal side effects from chemotherapy, whereas more patients had increased food take and an increase in Karnofsky performance status (KPS) score (p<0.01). In vitro, the expression of P-gp and sorcin in the HSS treated cells were lower than in the control group cells (p<0.01). When added to conventional chemotherapy, HSS improves the complete remission rates and quality of life in patients with acute leukemia. The in vitro findings indicate that suppression of P-gp and sorcin genes in leukemia cells may be involved in the beneficial effects of HSS. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Leal, M L R; Fialho, S S; Cyrillo, F C; Bertagnon, H G; Ortolani, E L; Benesi, F J
2012-01-01
The aim of this study was to compare the efficacy of treating osmotic diarrhea and dehydration in calves with hypertonic saline solution (HSS) IV, isotonic electrolyte solution (IES) PO, and a combination of these 2 solutions (HSS + IES). Eighteen male calves 8-30 days of age were used to evaluate the efficacy of 3 methods of fluid therapy after induction of osmotic diarrhea and dehydration. The diarrhea and dehydration were induced by administration of saccharose, spironolactone, and hydrochlorothiazide for 48 hours. The animals were randomly divided into 3 experimental groups: Group 1: 7.2% hypertonic saline solution-HSS (5 mL/kg IV); Group 2: oral isotonic electrolyte solution IES (60 mL/kg PO); or Group 3: HSS+IES. Clinical signs and laboratory finding observed 48 hours post-induction (Time 0) included diarrhea, dehydration, lethargy, and metabolic acidosis. Calves treated with HSS + IES experienced decreases in hematocrit, total protein concentration, albumin concentration, urea nitrogen concentration, and plasma volume as well as increases in blood pH, blood bicarbonate concentration, and central venous pressure between 1 and 3 hours post-treatment. These findings also were observed in animals treated with IES, however, at a slower rate than in the HSS + IES-treated animals. Animals treated with HSS continued to display signs of dehydration, lethargy, and metabolic acidosis 24 hours post-treatment. Treatment with a combination of HSS and IES produced rapid and sustainable correction of hypovolemia and metabolic acidosis in calves with noninfections diarrhea and dehydration. Copyright © 2012 by the American College of Veterinary Internal Medicine.
Hallermann-Streiff Syndrome: No Evidence for a Link to Laminopathies
Kortüm, F.; Chyrek, M.; Fuchs, S.; Albrecht, B.; Gillessen-Kaesbach, G.; Mütze, U.; Seemanova, E.; Tinschert, S.; Wieczorek, D.; Rosenberger, G.; Kutsche, K.
2011-01-01
Hallermann-Streiff syndrome (HSS) is a rare inherited disorder characterized by malformations of the cranium and facial bones, congenital cataracts, microphthalmia, skin atrophy, hypotrichosis, proportionate short stature, teeth abnormalities, and a typical facial appearance with prominent forehead, small pointed nose, and micrognathia. The genetic cause of this developmental disorder is presently unknown. Here we describe 8 new patients with a phenotype of HSS. Individuals with HSS present with clinical features overlapping with some progeroid syndromes that belong to the laminopathies, such as Hutchinson-Gilford progeria syndrome (HGPS) and mandibuloacral dysplasia (MAD). HGPS is caused by de novo point mutations in the LMNA gene, coding for the nuclear lamina proteins lamin A and C. MAD with type A and B lipodystrophy are recessive disorders resulting from mutations in LMNA and ZMPSTE24, respectively. ZMPSTE24 in addition to ICMT encode proteins involved in posttranslational processing of lamin A. We hypothesized that HSS is an allelic disorder to HGPS and MAD. As the nuclear shape is often irregular in patients with LMNA mutations, we first analyzed the nuclear morphology in skin fibroblasts of patients with HSS, but could not identify any abnormality. Sequencing of the genes LMNA, ZMPSTE24 and ICMT in the 8 patients with HSS revealed the heterozygous missense mutation c.1930C>T (p.R644C) in LMNA in 1 female. Extreme phenotypic diversity and low penetrance have been associated with the p.R644C mutation. In ZMPSTE24 and ICMT, no pathogenic sequence change was detected in patients with HSS. Together, we found no evidence that HSS is another laminopathy. PMID:22570643
Stability-indicating UPLC method for determining related substances and degradants in dronedarone.
Pydimarry, Surya Prakash Rao; Cholleti, Vijay Kumar; Vangala, Ranga Reddy
2014-08-01
A simple, sensitive and reproducible method was developed on ultra-performance liquid chromatography coupled with photodiode array detection for the quantitative determination of dronedarone hydrochloride (DRO) in drug substance and pharmaceutical dosage forms. The method is applicable for the quantification of related substances and assays of drug substances. Chromatographic separation was achieved on Acquity UPLC BEH C8 100 mm, 2.1 mm and 1.7 µm columns, using gradient elution within a short run time of 10.0 min. The eluted compounds were monitored at 288 nm, the flow rate was 0.5 mL/min and the column oven temperature was maintained at 40°C. The resolution of DRO and 11 impurities (potentials and by-products) was greater than 2.0 for all pairs of components. The high correlation coefficient value (>0.9995) indicates the clear correlations between the concentrations of investigated compound and their peak areas within the test ranges. The repeatability and intermediate precision, expressed by the relative standard deviation, were less than 2.5%. The accuracy and validity of the method were further ascertained by performing recovery studies via a spike method. The accuracy of the method, expressed as relative error, was satisfactory. No interference was observed from concomitant substances normally added to the tablets. DRO was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. DRO was found to degrade significantly in acid and base stress conditions and to remain stable in thermal, photolytic degradation, oxidative and hydrolytic conditions. The degradation products were well resolved from primary peak and its impurities, proving that the method is stability indicating. The developed method was validated as per International Conference on Harmonization guidelines with respect to specificity, limit of detection, limit of quantification, linearity, accuracy, precision, solution stability and robustness. This method is also suitable for the determination of DRO drug substance and pharmaceutical dosage forms. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Ultra high pressure liquid chromatography. Column permeability and changes of the eluent properties.
Gritti, Fabrice; Guiochon, Georges
2008-04-11
The behavior of four similar liquid chromatography columns (2.1mm i.d. x 30, 50, 100, and 150 mm, all packed with fine particles, average d(p) approximately 1.7 microm, of bridged ethylsiloxane/silica hybrid-C(18), named BEH-C(18)) was studied in wide ranges of temperature and pressure. The pressure and the temperature dependencies of the viscosity and the density of the eluent (pure acetonitrile) along the columns were also derived, using the column permeabilities and applying the Kozeny-Carman and the heat balance equations. The heat lost through the external surface area of the chromatographic column was directly derived from the wall temperature of the stainless steel tube measured with a precision of +/-0.2 degrees C in still air and +/-0.1 degrees C in the oven compartment. The variations of the density and viscosity of pure acetonitrile as a function of the temperature and pressure was derived from empirical correlations based on precise experimental data acquired between 298 and 373 K and at pressures up to 1.5 kbar. The measurements were made with the Acquity UPLC chromatograph that can deliver a maximum flow rate of 2 mL/min and apply a maximum column inlet pressure of 1038 bar. The average Kozeny-Carman permeability constant of the columns was 144+/-3.5%. The temperature hence the viscosity and the density profiles of the eluent along the column deviate significantly from linear behavior under high-pressure gradients. For a 1000 bar pressure drop, we measured DeltaT=25-30 K, (Deltaeta/eta) approximately 100%, and (Deltarho/rho) approximately 10%. These results show that the radial temperature profiles are never fully developed within 1% for any of the columns, even under still-air conditions. This represents a practical advantage regarding the apparent column efficiency at high flow rates, since the impact of the differential analyte velocity between the column center and the column wall is not maximum. The interpretation of the peak profiles recorded in UPLC is discussed.
Wu, Hao Bin; Lou, Xiong Wen David; Hng, Huey Hoon
2012-02-13
Layered protonated titanates (LPTs), a class of interesting inorganic layered materials, have been widely studied because of their many unique properties and their use as precursors to many important TiO(2)-based functional materials. In this work, we have developed a facile solvothermal method to synthesize hierarchical spheres (HSs) assembled from ultrathin LPT nanosheets. These LPT hierarchical spheres possess a porous structure with a large specific surface area and high stability. Importantly, the size and morphology of the LPT hierarchical spheres are easily tunable by varying the synthesis conditions. These LPT HSs can be easily converted to anatase TiO(2) HSs without significant structural alteration. Depending on the calcination atmosphere of air or N(2), pure anatase TiO(2) HSs or carbon-supported TiO(2) HSs, respectively, can be obtained. Remarkably, both types of TiO(2) HSs manifest excellent cyclability and rate capability when evaluated as anode materials for high-power lithium-ion batteries. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Stegemann, Thomas; Sievert, Christian
2017-01-01
Pyrrolizidine alkaloids (PAs) are toxic secondary metabolites that are found in several distantly related families of the angiosperms. The first specific step in PA biosynthesis is catalyzed by homospermidine synthase (HSS), which has been recruited several times independently by duplication of the gene encoding deoxyhypusine synthase, an enzyme involved in the posttranslational activation of the eukaryotic initiation factor 5A. HSS shows highly diverse spatiotemporal gene expression in various PA-producing species. In comfrey (Symphytum officinale; Boraginaceae), PAs are reported to be synthesized in the roots, with HSS being localized in cells of the root endodermis. Here, we show that comfrey plants activate a second site of HSS expression when inflorescences start to develop. HSS has been localized in the bundle sheath cells of specific leaves. Tracer feeding experiments have confirmed that these young leaves express not only HSS but the whole PA biosynthetic route. This second site of PA biosynthesis results in drastically increased PA levels within the inflorescences. The boost of PA biosynthesis is proposed to guarantee optimal protection especially of the reproductive structures. PMID:28275146
Non-Standard Italian Dialect Heritage Speakers' Acquisition of Clitic Placement in Standard Italian
ERIC Educational Resources Information Center
Chan, Lionel
2014-01-01
This dissertation examines the acquisition of object clitic placement in Standard Italian by heritage speakers (HSs) of non-standard Italian dialects. It compares two different groups of Standard Italian learners--Northern Italian dialect HSs and Southern Italian dialect HSs--whose heritage dialects contrast with each other in clitic word order.…
Cognitive, cultural, and linguistic sources of a handshape distinction expressing agentivity.
Brentari, Diane; Di Renzo, Alessio; Keane, Jonathan; Volterra, Virginia
2015-01-01
In this paper the cognitive, cultural, and linguistic bases for a pattern of conventionalization of two types of iconic handshapes are described. Work on sign languages has shown that handling handshapes (H-HSs: those that represent how objects are handled or manipulated) and object handshapes (O-HSs: those that represent the class, size, or shape of objects) express an agentive/non-agentive semantic distinction in many sign languages. H-HSs are used in agentive event descriptions and O-HSs are used in non-agentive event descriptions. In this work, American Sign Language (ASL) and Italian Sign Language (LIS) productions are compared (adults and children) as well as the corresponding groups of gesturers in each country using "silent gesture." While the gesture groups, in general, did not employ an H-HS/O-HS distinction, all participants (signers and gesturers) used iconic handshapes (H-HSs and O-HSs together) more often in agentive than in no-agent event descriptions; moreover, none of the subjects produced an opposite pattern than the expected one (i.e., H-HSs associated with no-agent descriptions and O-HSs associated with agentive ones). These effects are argued to be grounded in cognition. In addition, some individual gesturers were observed to produce the H-HS/O-HS opposition for agentive and non-agentive event descriptions-that is, more Italian than American adult gesturers. This effect is argued to be grounded in culture. Finally, the agentive/non-agentive handshape opposition is confirmed for signers of ASL and LIS, but previously unreported cross-linguistic differences were also found across both adult and child sign groups. It is, therefore, concluded that cognitive, cultural, and linguistic factors contribute to the conventionalization of this distinction of handshape type. Copyright © 2014 Cognitive Science Society, Inc.
Reimann, Andreas; Nurhayati, Niknik; Backenköhler, Anita; Ober, Dietrich
2004-01-01
Species of several unrelated families within the angiosperms are able to constitutively produce pyrrolizidine alkaloids as a defense against herbivores. In pyrrolizidine alkaloid (PA) biosynthesis, homospermidine synthase (HSS) catalyzes the first specific step. HSS was recruited during angiosperm evolution from deoxyhypusine synthase (DHS), an enzyme involved in the posttranslational activation of eukaryotic initiation factor 5A. Phylogenetic analysis of 23 cDNA sequences coding for HSS and DHS of various angiosperm species revealed at least four independent recruitments of HSS from DHS: one within the Boraginaceae, one within the monocots, and two within the Asteraceae family. Furthermore, sequence analyses indicated elevated substitution rates within HSS-coding sequences after each gene duplication, with an increased level of nonsynonymous mutations. However, the contradiction between the polyphyletic origin of the first enzyme in PA biosynthesis and the structural identity of the final biosynthetic PA products needs clarification. PMID:15466410
Chen, Mengchun; Song, Wenjie; Wang, Shuanghu; Chen, Qiulei; Pan, Peipei; Xu, Tao; Hu, Guoxin; Zheng, Zhiqiang
2016-08-01
A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the simultaneous determination of bosentan (BOS), glimepiride (GLP), hydroxyl bosentan (HYBOS) and hydroxyl glimepiride (M1) in rat plasma using one-step protein precipitation was developed and validated. After addition of ambrisentan as an internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm particle size, Waters Corp., Milford, MA, USA) and inline 0.2 μm stainless steel frit filter (Waters Corp.) with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min with gradient elution. The column temperature was maintained at 40°C. Only 4 min was needed for an analytical run. The retention times were ∼3.29 min for BOS, 3.56 min for GLP, 1.42 min for HYBOS, 1.53 min for M1 and 3.22 min for IS. Electrospray ionization source was employed and operated in positive-ion mode; multiple reaction monitoring mode was applied to target fragment ions m/z 552 → 202, m/z 568 → 202, m/z 491 → 352, m/z 507 → 352 and m/z 379 → 347 for BOS, HYBOS, GLP, M1 and IS, respectively. The assay was validated over concentration ranges of 25-5,000 ng/mL (r(2) = 0.9984) for BOS, 1-200 ng/mL (r(2) = 0.9999) for GLP, 0.5-100 ng/mL (r(2) = 0.9999) for HYBOS and 0.1-20 ng/mL (r(2) = 0.9984) for M1. Intra- and interday precision values for replicate quality control samples were within 14.2% for all analytes during the assay validation. Mean quality control accuracy values were within -3.3 to 14.4% of nominal values for all analytes. The mean recoveries of BOS, GLP, HYBOS, M1 and ambrisentan from the plasma exceeded 90.4%. The analytes were stable in rat plasma for at least 2 h at room temperature, 30 days at -40°C and following at least three freeze-thaw cycles (-40°C to room temperature). This method was successfully applied to a pharmacokinetic study of coadministeration of BOS and GLP in rats. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Tsytsykova, Alla V.; Rajsbaum, Ricardo; Falvo, James V.; Ligeiro, Filipa; Neely, Simon R.; Goldfeld, Anne E.
2007-01-01
Here we provide a mechanism for specific, efficient transcription of the TNF gene and, potentially, other genes residing within multigene loci. We identify and characterize highly conserved noncoding elements flanking the TNF gene, which undergo activation-dependent intrachromosomal interactions. These elements, hypersensitive site (HSS)−9 and HSS+3 (9 kb upstream and 3 kb downstream of the TNF gene, respectively), contain DNase I hypersensitive sites in naive, T helper 1, and T helper 2 primary T cells. Both HSS-9 and HSS+3 inducibly associate with acetylated histones, indicative of chromatin remodeling, bind the transcription factor nuclear factor of activated T cells (NFAT)p in vitro and in vivo, and function as enhancers of NFAT-dependent transactivation mediated by the TNF promoter. Using the chromosome conformation capture assay, we demonstrate that upon T cell activation intrachromosomal looping occurs in the TNF locus. HSS-9 and HSS+3 each associate with the TNF promoter and with each other, circularizing the TNF gene and bringing NFAT-containing nucleoprotein complexes into close proximity. TNF gene regulation thus reveals a mode of intrachromosomal interaction that combines a looped gene topology with interactions between enhancers and a gene promoter. PMID:17940009
Anaerobic decomposition of humic substances by Clostridium from the deep subsurface
Ueno, Akio; Shimizu, Satoru; Tamamura, Shuji; Okuyama, Hidetoshi; Naganuma, Takeshi; Kaneko, Katsuhiko
2016-01-01
Decomposition of humic substances (HSs) is a slow and cryptic but non-negligible component of carbon cycling in sediments. Aerobic decomposition of HSs by microorganisms in the surface environment has been well documented; however, the mechanism of anaerobic microbial decomposition of HSs is not completely understood. Moreover, no microorganisms capable of anaerobic decomposition of HSs have been isolated. Here, we report the anaerobic decomposition of humic acids (HAs) by the anaerobic bacterium Clostridium sp. HSAI-1 isolated from the deep terrestrial subsurface. The use of 14C-labelled polycatechol as an HA analogue demonstrated that the bacterium decomposed this substance up to 7.4% over 14 days. The decomposition of commercial and natural HAs by the bacterium yielded lower molecular mass fractions, as determined using high-performance size-exclusion chromatography. Fourier transform infrared spectroscopy revealed the removal of carboxyl groups and polysaccharide-related substances, as well as the generation of aliphatic components, amide and aromatic groups. Therefore, our results suggest that Clostridium sp. HSAI-1 anaerobically decomposes and transforms HSs. This study improves our understanding of the anaerobic decomposition of HSs in the hidden carbon cycling in the Earth’s subsurface. PMID:26743007
On the Detectability of the X 2A" HSS, HSO, and HOS Radicals in the Interstellar Medium
NASA Astrophysics Data System (ADS)
Fortenberry, Ryan C.; Francisco, Joseph S.
2017-02-01
{\\tilde{X}}2A\\prime\\prime HSS has yet to be observed in the gas phase in the interstellar medium (ISM). HSS has been observed in cometary material and in high abundance. However, its agglomeration to such bodies or dispersal from them has not been observed. Similarly, HSO and HOS have not been observed in the ISM, either, even though models support their formation from reactions of known sulfur monoxide and hydrogen molecules, among other pathways. Consequently, this work provides high-level, quantum chemical rovibrational spectroscopic constants and vibrational frequencies in order to assist in interstellar searches for these radical molecules. Furthermore, the HSO-HOS isomerization energy is determined to be 3.63 kcal mol-1, in line with previous work, and the dipole moment of HOS is 36% larger at 3.87 D than HSO, making the less stable isomer more rotationally intense. Finally, the S-S bond strength in HSS is shown to be relatively weak at 30% of the typical disulfide bond energy. Consequently, HSS may degrade into SH and sulfur atoms, making any ISM abundance of HSS likely fairly low, as recent interstellar surveys have observed.
Narin, Selnur; Unver, Bayram; Bakırhan, Serkan; Bozan, Ozgür; Karatosun, Vasfi
2014-01-01
The purpose of this study was to adapt the English version of the Hospital for Special Surgery (HSS) knee score for use in a Turkish population and to evaluate its validity, reliability and cultural adaptation. Standard forward-back translation of the HSS knee score was performed and the Turkish version was applied in 73 patients. The Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), Mini-Mental State Examination and sit-to-stand test were also performed and analyzed. Internal consistency reliability was tested using Cronbach's alpha. The intraclass correlation coefficient (ICC) was used to calculate the test-retest reliability at one-week intervals. Validity was assessed by calculating the Pearson correlation between the HSS, WOMAC and sit-to-stand test scores. The ICC ranged from 0.98 to 0.99 with high internal consistency (Cronbach's alpha: 0.87). The WOMAC score correlated with total HSS score (r: -0.80, p<0.001) and sit-to-stand score (r: 0.12, p: 0.312). The Turkish version of the HSS knee score is reliable and valid in evaluating the total knee arthroplasty in Turkish patients.
Fan, Victoria Y; Tsai, Feng-Jen J; Shroff, Zubin C; Nakahara, Branden; Vargha, Nabil; Weathers, Scott
2017-01-01
This study aims to understand the determinants of the Global Fund to Fight AIDS, Tuberculosis, and Malaria's dedicated channel for health systems strengthening (HSS) funding across countries and to analyze their health system priorities expressed in budgets and performance indicators. We obtained publicly available data for disease-specific and HSS grants from the Global Fund over 2004-2013 prior to the new funding model. Regression analysis was employed to assess the determinants of dedicated HSS funding across 111 countries. Documents for 27 dedicated HSS grants including budgets and performance indicators were collected, and activities were analyzed by health system functions. HSS funding per capita is significantly associated with TB and HIV funding per capita, but not per capita income and health worker density. Of 27 dedicated HSS grants, 11 had line-item budgets publicly available, in which health workforce and medical products form the majority (89% or US$132 million of US$148 million) of funds. Yet these areas accounted for 41.7% (215) of total 516 performance indicators. Health worker densities were not correlated with HSS funding, despite the emphasis on health workforce in budgets and performance indicators. Priorities in health systems in line-item budgets differ from the numbers of indicators used. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
β-Globin locus control region HS2 and HS3 interact structurally and functionally
Jackson, David A.; McDowell, Jennifer C.; Dean, Ann
2003-01-01
The overall structure of the DNase I hypersensitive sites (HSs) that comprise the β-globin locus control region (LCR) is highly conserved among mammals, implying that the HSs have conserved functions. However, it is not well understood how the LCR HSs, either individually or collectively, activate transcription. We analyzed the interactions of HS2, HS3 and HS4 with the human ε- and β-globin genes in chromatinized episomes in fetal/embryonic K562 cells. Only HS2 activates transcription of the ε-globin gene, while all three HSs activate the β-globin gene. HS3 stimulates the β-globin gene constitutively, but HS2 and HS4 transactivation requires expression of the transcription factor EKLF, which is not present in K562 cells but is required for β-globin expression in vivo. To begin addressing how the individual HSs may interact with one another in a complex, we linked the β-globin gene to both the HS2 and HS3. HS2 and HS3 together resulted in synergistic stimulation of β-globin transcription. Unexpectedly, mutated, inactive forms of HS2 impeded the activation of the β-globin gene by HS3. Thus, there appear to be distinct interactions among the HSs and between the HSs and the globin genes. These preferential, non-exclusive interactions may underlie an important structural and functional cooperativity among the regulatory sequences of the β-globin locus in vivo. PMID:12582237
Desta, Z; Abula, T; Beyene, L; Fantahun, M; Yohannes, A G; Ayalew, S
1997-12-01
A study on rational drug use was undertaken in nine health centres (HCs) and nine health stations (HSs) in Ethiopia. Prescribing, patient care and facility specific factors were measured using drug use indicators. Prescribing patterns of drugs were also assessed. With only few exceptions, the drug use indicators in HCs and HSs and between retrospective and prospective studies were similar despite differences in manpower and facilities. The average consultation time (in minutes) in HSs and HCs was 5.1 +/- 0.8 and 5.8 +/- 1.06, respectively. The dispensing time (in minutes) was 1.5 +/- 0.7 in HSs and 1.9 +/- 0.6 in HCs. Both patient care indicators seem to be adequate to influence patient satisfaction to the overall health service and patient knowledge of important dosage instructions. Most drugs (more than 89% in HCs and 71% in HSs) were actually dispensed from the health facilities and labelling was satisfactory. Prescribing by generic names (average: 75% in HCs and 83% in HSs) was encouraging. While the availability of key drugs was ensured, essential documents were missing in most facilities or they were unpopular for use, and those available required revision and updating. Polypharmacy in which the number of drugs/encounter was < 2.5 was minimal, but that a large proportion of the prescriptions contained two or more drugs could result in adverse drug-drug interactions. The most frequently prescribed drugs were anti-infectives and analgesics accounting for over 76% in HCs and 82% in HSs and in most cases they are probably prescribed with little justification. The exposure of patients to antibiotics (average: 60% in HCs and 65% in HSs) was unacceptably high to justify epidemiological trends. The high exposure of patients to injections, especially in the HSs (over 37%), should be seen from the health and economic points of view. The results revealed priority areas for intervention. They also provide standard references to compare drug use situations and their change over time in different settings, area and time in Ethiopia.
NASA Astrophysics Data System (ADS)
Yurov, D. V.; Prikhod'ko, V. V.
2014-11-01
The features of subcritical hybrid systems (HSs) are discussed in the context of burning up transuranic wastes from the U-Pu nuclear fuel cycle. The advantages of HSs over conventional atomic reactors are considered, and fuel cycle closure alternatives using HSs and fast neutron reactors are comparatively evaluated. The advantages and disadvantages of two HS types with neutron sources (NSs) of widely different natures -- nuclear spallation in a heavy target by protons and nuclear fusion in magnetically confined plasma -- are discussed in detail. The strengths and weaknesses of HSs are examined, and demand for them for closing the U-Pu nuclear fuel cycle is assessed.
Hou, J W
2003-07-01
Hallermann-Streiff syndrome (HSS) is a rare clinic entity of unknown aetiology. Further clinical and metabolic-genetic evaluations are indicated. A 2-mo-old female baby presented with ocular abnormalities and severe failure to thrive since birth. The clinical features were compatible with the diagnosis of HSS. Further imaging, metabolic and cytogenetic examinations were performed. Features characteristic of HSS were dyscephaly with mandibular and nasal cartilage hypoplasia, microphthalmia, bilateral cataracts with congenital glaucoma, natal teeth and proportionate dwarfism. Rare anomalies such as choanal atresia and small cerebellum, very low insulin-like growth factor I level, hypothyroidism, generalized organic aciduria were also noticed. An increased chromosomal breakage rate is suggestive of the existence of some DNA repair defects in HSS patients. The associated anomalies in this patient may broaden the clinical spectrum of HSS. Underlying conditions of organic aciduria, growth factor deficiency and impaired DNA repair are likely to contribute to the progeria-like facies, congenital cataracts and growth failure.
Loera, Barbara; Converso, Daniela; Viotti, Sara
2014-01-01
Background The Maslach Burnout Inventory (MBI) is the mainstream measure for burnout. However, its psychometric properties have been questioned, and alternative measurement models of the inventory have been suggested. Aims Different models for the number of items and factors of the MBI-HSS, the version of the Inventory for the Human Service sector, were tested in order to identify the most appropriate model for measuring burnout in Italy. Methods The study dataset consisted of a sample of 925 nurses. Ten alternative models of burnout were compared using confirmatory factor analysis. The psychometric properties of items and reliability of the MBI-HSS subscales were evaluated. Results Item malfunctioning may confound the MBI-HSS factor structure. The analysis confirmed the factorial structure of the MBI-HSS with a three-dimensional, 20-item assessment. Conclusions The factorial structure underlying the MBI-HSS follows Maslach’s definition when items are reduced from the original 22 to a 20-item set. Alternative models, either with fewer items or with an increased number of latent dimensions in the burnout structure, do not yield better results to justify redefining the item set or theoretically revising the syndrome construct. PMID:25501716
Hallerman-Streiff-like syndrome presenting with laterality and cardiac defects.
Morice-Picard, Fanny; Marlin, Sandrine; Rooryck, Caroline; Fayon, Mickael; Thambo, Jeao-Benoît; Demarquez, Jean-Louis; Fauroux, Brigitte; Denoyelle, Francoise; Lacombe, Didier
2009-04-01
We report two patients considered to have an atypical presentation of Hallerman-Streiff syndrome (HSS) associated with laterality and cardiac defects. Clinical features include typical facial gestalt, atrophy of the skin, and hypotrichosis. Ophthalmologic abnormalities, normally present in HSS, are only found in one of the two patients. Both of them have respiratory problems secondary to the classical narrow upper airway described in this syndrome. Both these patients have laterality defects and one has additional structural cardiac malformations. Cardiac defects have occasionally been reported in the HSS literature, but are not considered as a classical feature of the syndrome. Situs inversus has never been reported in this syndrome. Almost all HSS cases have been sporadic and their origin and inheritance pattern remain unknown.
Cheng, Jian; Di, Liu-Qing; Shan, Jin-Jun; Zhao, Xiao-Li; Kang, An; Bi, Xiao-Lin; Li, Jun-Song
2014-04-01
To study on the effects of Achyranthes bidentata on Tongsaimai pellets main active ingredients chlorogenic acid, isoliquiritin, harpagoside and glycyrrhizin in rats in vivo pharmacokinetic behaviors, a method for the simultaneous determination of chlorogenic acid, isoliquiritin, harpagoside and liquiritigenin in rat plasma was established by UPLC-MS/MS. The analysis was performed on a waters Acquity BEH C18 column (2.1 mm x 100 mm, 1.7 microm) with the mixture of acetonitrile and 0.1% formic acid/water as mobile phase, and the gradient elution at a flow rate of 0.3 mL x min(-1). The analytes were detected by tandem mass spectrometry with the electrospray ionization (ESI) source and in the multiple reaction monitoring (MRM) mode. It turned out that the analytes of Tongsaimai pellets groups C(max) and AUC(Q-infinity) values were higher than that with A. bidentata group, and the C(max) values of chlorogenic acid had significantly difference (P < 0.05), the AUC(0-infinity) values of chlorogenic acid and glycyrrhizin had significantly difference (P < 0.05); The T(max) and CL values of two groups had no significantly difference. Results showed that the established method was specific, rapid, accurate and sensitive for the studies of Tongsaimai pellets four main active ingredients in rat in vivo pharmacokinetic, and A. bidentata have varying degrees of effects on Tongsaimai pellets four main active ingredients in rat in vivo pharmacokinetic behaviors.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Pingili Sunil; Prakash, Lakkireddy
2012-01-01
A novel, sensitive and selective stability-indicating gradient reverse phase ultra performance liquid chromatographic method was developed and validated for the quantitative determination of desloratadine and sodium benzoate in pharmaceutical oral liquid formulation. The chromatographic separation was achieved on Acquity BEH C8 (100 mm × 2.1 mm) 1.7 μm column by using mobile phase containing a gradient mixture of solvent A (0.05 M KH(2)PO(4) and 0.07 M triethylamine, pH 3.0) and B (50:25:25 v/v/v mixture of acetonitrile, methanol and water) at flow rate of 0.4 mL/min. Column temperature was maintained at 40°C and detection was carried out at a wavelength of 272 nm. The described method shows excellent linearity over a range of 0.254 μg/mL to 76.194 μg/mL for desloratadine and 1.006 μg/mL to 301.67 μg/mL for sodium benzoate. The correlation coefficient for desloratadine and sodium benzoate was more than 0.999. To establish stability-indicating capability of the method, drug product was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal and photolytic degradation. The degradation products were well resolved from desloratadine and sodium benzoate. The developed method was validated as per international ICH guidelines with respect to specificity, linearity, LOD, LOQ, accuracy, precision and robustness.
Han, Zheng; Zheng, Yunliang; Chen, Na; Luan, Lianjun; Zhou, Changxin; Gan, Lishe; Wu, Yongjiang
2008-11-28
A new separation and quantification method using liquid chromatography under ultra-high-pressure in combination with tandem mass spectrometry (MS/MS) was developed for simultaneous determination of four alkaloids in Lindera aggregata. The analysis was performed on an Acquity UPLC BEH C(18) column (50mmx2.1mm, 1.7microm particle size; Waters, Milford, MA, USA) utilizing a gradient elution profile and a mobile phase consisting of (A) water containing 10mM ammonium acetate adjusted to pH 3 with acetic acid and (B) acetonitrile. An electrospray ionization (ESI)-tandem interface in the positive mode was employed prior to mass spectrometric detection. The calibration curve was linear over the range of 17.1-856ng for boldine, 42.4-2652ng for norboldine, 6.1-304ng for reticuline and 0.5-50ng for linderegatine, respectively. The average recoveries ranged from 99.2 to 101.4% with RSDs< or =2.7%. Then, four L. aggregata samples from different batches were analyzed using the established method. The results indicated that ultra-high-pressure liquid chromatography-tandem mass spectrometry provided improved chromatographic parameters resulting in significantly increased sample throughput including lower solvent consumption and lower limits of quantitation (LOQs) for most of target analytes compared to previous method employing conventional high-performance liquid chromatography (HPLC) separation. So, the established method was validated, sensitive and reliable for the determination of four alkaloids in L. aggregata.
Han, Miaomiao; Tian, Ying; Li, Zhen; Chen, Yiqiang; Yang, Wenjun; Zhang, Liying
2017-12-01
Chromium picolinate is one of the important Cr 3+ resources and is widely used in animal production. A convenient, reliable and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative determination of chromium picolinate in animal feeds. Feed samples were extracted with acetonitrile and subsequently cleaned up by solid phase extraction cartridges Supelclean™ LC-18. Chromium picolinate was efficiently separated with a Waters ACQUITY UPLC ® BEH C18 column, ionized with electrospray ion source in positive mode (ESI + ), and quantitatively determined by tandem mass spectrometry in multiple reaction monitoring mode. Standard calibration curve of chromium picolinate in the concentration range from 0.5 to 1000ng/mL was obtained with good linearity correlation coefficient (R 2 =0.9982). Average recoveries ranged from 95.37%∼105.54%, as detected by spiking 0.02∼640mg/kg of chromium picolinate in complete feed, concentrated feed and premix. Intra-day and inter-day coefficient of variation were 0.59%∼6.67% and 2.36%∼6.97%, respectively. The limits of quantitation were 0.02mg/kg, 0.025mg/kg, and 2mg/kg for complete feed, concentrated feed, and premix, respectively. Actual sample analysis indicated that the developed method can be an effective tool to monitoring CrPic content in animal feed. Copyright © 2017. Published by Elsevier B.V.
Guo, Zhening; Chen, Yangsheng; Ding, Xiaoliang; Huang, Chenrong; Miao, Liyan
2016-11-01
A rapid, selective and sensitive liquid chromatography-tandem mass spectrometry assay method was developed for simultaneous determination of ambroxol and salbutamol in human plasma using citalopram hydrobromide as internal standard (IS). The sample was alkalinized with ammonia water (33:67, v/v) and extracted by single liquid-liquid extraction with ethyl acetate. Separation was achieved on Waters Acquity UPLC BEH C 18 column using a gradient program at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion multiple reaction monitoring mode by monitoring the ion transitions m/z 378.9 → 263.6 (ambroxol), m/z 240.2 → 147.7 (salbutamol) and m/z 325.0 → 261.7 (IS). The total analytical run time was relatively short (3 min). Calibration curves were linear in the concentration range of 0.5-100.0 ng/mL for ambroxol and 0.2-20.0 ng/mL for salbutamol, with intra- and inter-run precision (relative standard deviation) <15% and accuracy (relative error) ranging from 97.7 to 112.1% for ambroxol and from 94.5 to 104.1% for salbutamol. The method was successfully applied in a clinical pharmacokinetic study of the compound ambroxol and salbutamol tablets. Copyright © 2016 John Wiley & Sons, Ltd.
Shaw, Frances L.; Elliott, Katherine A.; Kinch, Lisa N.; Fuell, Christine; Phillips, Margaret A.; Michael, Anthony J.
2010-01-01
Polyamines are small flexible organic polycations found in almost all cells. They likely existed in the last universal common ancestor of all extant life, and yet relatively little is understood about their biological function, especially in bacteria and archaea. Unlike eukaryotes, where the predominant polyamine is spermidine, bacteria may contain instead an alternative polyamine, sym-homospermidine. We demonstrate that homospermidine synthase (HSS) has evolved vertically, primarily in the α-Proteobacteria, but enzymatically active, diverse HSS orthologues have spread by horizontal gene transfer to other bacteria, bacteriophage, archaea, eukaryotes, and viruses. By expressing diverse HSS orthologues in Escherichia coli, we demonstrate in vivo the production of co-products diaminopropane and N1-aminobutylcadaverine, in addition to sym-homospermidine. We show that sym-homospermidine is required for normal growth of the α-proteobacterium Rhizobium leguminosarum. However, sym-homospermidine can be replaced, for growth restoration, by the structural analogues spermidine and sym-norspermidine, suggesting that the symmetrical or unsymmetrical form and carbon backbone length are not critical for polyamine function in growth. We found that the HSS enzyme evolved from the alternative spermidine biosynthetic pathway enzyme carboxyspermidine dehydrogenase. The structure of HSS is related to lysine metabolic enzymes, and HSS and carboxyspermidine dehydrogenase evolved from the aspartate family of pathways. Finally, we show that other bacterial phyla such as Cyanobacteria and some α-Proteobacteria synthesize sym-homospermidine by an HSS-independent pathway, very probably based on deoxyhypusine synthase orthologues, similar to the alternative homospermidine synthase found in some plants. Thus, bacteria can contain alternative biosynthetic pathways for both spermidine and sym-norspermidine and distinct alternative pathways for sym-homospermidine. PMID:20194510
Eskelinen, Matti; Korhonen, Riika; Selander, Tuomas; Ollonen, Paula
2015-04-01
The relation between scoring for hopelessness/helplessness and the Montgomery-Asberg Depression Rating Scale (MADRS) in healthy study subjects (HSS) and in patients with benign breast disease (BBD) and breast cancer (BC) has not been compared in a prospective study. We, therefore, investigated hopelessness and helplessness scores versus the MADRS in 115 patients. In the Kuopio Breast Cancer Study, 115 women with breast symptoms were evaluated for hopelessness and helplessness, and for the MADRS before any diagnostic procedures were carried out. In the self-rating score (SRS), hopelessness/helplessness versus the MADRS were highly significantly positively correlated in the HSS, BBD and BC groups. In the SRS, the weighted kappa values for hopelessness/helplessness versus the MADRS in the HSS, BBD and BC groups were also statistically significant. There was also a significant positive correlation in the examiner-rating score (ERS) for hopelessness versus the MADRS in the HSS, BBD and BC groups and for helplessness versus the MADRS in the HSS, BBD and BC groups. The unweighted kappa values in the ERS for hopelessness versus the MADRS were statistically highly significant for the HSS, BBD and BC groups and those for helplessness versus the MADRS in the HSS and BBD groups were statistically significant. A new finding with clinical relevance in the present work is the agreement between hopelessness/helplessness scores and MADRS in the SRS and ERS. In the breast cancer diagnostic unit, the identification of hopeless/helpless persons is essential in suicide prevention and it is important to assess and treat hopelessness/helplessness even though an individual may report few depressive symptoms. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Gor, Kira
2014-01-01
Second language learners perform worse than native speakers under adverse listening conditions, such as speech in noise (SPIN). No data are available on heritage language speakers' (early naturalistic interrupted learners') ability to perceive SPIN. The current study fills this gap and investigates the perception of Russian speech in multi-talker babble noise by the matched groups of high- and low-proficiency heritage speakers (HSs) and late second language learners of Russian who were native speakers of English. The study includes a control group of Russian native speakers. It manipulates the noise level (high and low), and context cloze probability (high and low). The results of the SPIN task are compared to the tasks testing the control of phonology, AXB discrimination and picture-word discrimination, and lexical knowledge, a word translation task, in the same participants. The increased phonological sensitivity of HSs interacted with their ability to rely on top-down processing in sentence integration, use contextual cues, and build expectancies in the high-noise/high-context condition in a bootstrapping fashion. HSs outperformed oral proficiency-matched late second language learners on SPIN task and two tests of phonological sensitivity. The outcomes of the SPIN experiment support both the early naturalistic advantage and the role of proficiency in HSs. HSs' ability to take advantage of the high-predictability context in the high-noise condition was mitigated by their level of proficiency. Only high-proficiency HSs, but not any other non-native group, took advantage of the high-predictability context that became available with better phonological processing skills in high-noise. The study thus confirms high-proficiency (but not low-proficiency) HSs' nativelike ability to combine bottom-up and top-down cues in processing SPIN.
Millot, Benjamin; Montoliu, Lluís; Fontaine, Marie-Louise; Mata, Teresa; Devinoy, Eve
2003-01-01
The upstream regulatory regions of the mouse and rabbit whey acidic protein (WAP) genes have been used extensively to target the efficient expression of foreign genes into the mammary gland of transgenic animals. Therefore both regions have been studied to elucidate fully the mechanisms controlling WAP gene expression. Three DNase I-hypersensitive sites (HSS0, HSS1 and HSS2) have been described upstream of the rabbit WAP gene in the lactating mammary gland and correspond to important regulatory regions. These sites are surrounded by variable chromatin structures during mammary-gland development. In the present study, we describe the upstream sequence of the mouse WAP gene. Analysis of genomic sequences shows that the mouse WAP gene is situated between two widely expressed genes (Cpr2 and Ramp3). We show that the hypersensitive sites found upstream of the rabbit WAP gene are also detected in the mouse WAP gene. Further, they encompass functional signal transducer and activator of transcription 5-binding sites, as has been observed in the rabbit. A new hypersensitive site (HSS3), not specific to the mammary gland, was mapped 8 kb upstream of the rabbit WAP gene. Unlike the three HSSs described above, HSS3 is also detected in the liver, but similar to HSS1, it does not depend on lactogenic hormone treatments during cell culture. The region surrounding HSS3 encompasses a potential matrix attachment region, which is also conserved upstream of the mouse WAP gene and contains a functional transcription factor Ets-1 (E26 transformation-specific-1)-binding site. Finally, we demonstrate for the first time that variations in the chromatin structure are dependent on prolactin alone. PMID:12580766
Hemispherical spondylosclerosis - a polyetiologic syndrome
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dihlmann, W.
1981-11-01
Radiologic examination of 43 patients revealed 47 lesions of a type which we have termed hemispherical spondylosclerosis (HSS). This term describes and includes the following essential and possible radiologic findings of the disease: 1) Hemispherical (or dome - or helmet-shaped ) sclerosis of the vertebra above the intervertebral disk. Thus it is a supradiscal HSS. 2) One or more small erosions of the inferior end plate of the vertebra involved. 3) Periosteal apposition on the anterior border of the vertebra along the length of the sclerosis. 4) New bone formation on the inferior end plate. 5) Anterior vertebral osteophytes. 6)more » Narrowing of the disk space below the affected vertebra. HSS occurs not only as a sequel of degenerative disk disease, but also in bacterial (tuberculous and non-tuberculous) spondylitis, ankylosing spondylitis, osteoid osteoma, and metastases of neoplasms. The differential diagnosis between inflammatory and non-inflammatory pathogenesis and etiology of HSS is described. The characteristic shape of HSS, its sites of predilection (L4 >> L5 > L3), and the preponderance of female sufferers from this painful condition are due to factors which, as yet, remain unknown.« less
Formation of Humic Substances in Weathered MSWI Bottom Ash
Zhang, Haixia; Shimaoka, Takayuki
2013-01-01
The study aimed at evaluating the humic substances (HSs) content from municipal solid waste incinerator (MSWI) bottom ash and its variation with time and the effect of temperature on HSs formation. The process suggested by IHSS was applied to extract HSs from two different bottom ash samples, and the extracted efficiency with NaOH and Na4P2O7 was compared. MSWI bottom ash samples were incubated at 37°C and 50°C for 1 year. HSs and nonhumic substances were extracted from the bottom ash sample with different incubated period by 0.1 M NaOH/Na4P2O7. Results show that the rate of humic acid formation increased originally with incubation time, reached a maximum at 12th week under 37°C and at 18th week under 50°C, and then decreased with time. More humic acid in MSWI bottom ash was formed under 50°C incubated condition compared with that incubated under 37°C. Also, the elemental compositions of HSs extracted from bottom ash are reported. PMID:23844394
Symptom rating scale for assessing hyperthyroidism.
Klein, I; Trzepacz, P T; Roberts, M; Levey, G S
1988-02-01
A hyperthyroid symptom scale (HSS) was designed and administered to ten subjects with untreated Graves' disease. All subjects had clinical and chemical evidence of hyperthyroidism and reproducible HSS scores of 20 or more points. During sequential treatments with propranolol hydrochloride (phase 2) followed by propylthiouracil (phase 3) there was a significant decline in the HSS scores at each phase. Accompanying the decrease in HSS scores was a decrease in heart rate, but there was no change in thyroid function test results at phase 2 and a decrease in heart rate, thyroid function test results, and goiter size at phase 3. This new scale includes ten categories of symptoms, it is sensitive to changes in both the adrenergic and metabolic components of hyperthyroidism, and it is useful in the clinical assessment and management of patients with thyrotoxicosis.
Boumrah, Yacine; Humbert, Luc; Phanithavong, Melodie; Khimeche, Kamel; Dahmani, Abdallah; Allorge, Delphine
2016-02-01
One of the main challenges posed by the emergence of new psychoactive substances is their identification in human biological samples. Trying to detect the parent drug could lead to false-negative results when the delay between consumption and sampling has been too long. The identification of their metabolites could then improve their detection window in biological matrices. Oxidative metabolism by cytochromes P450 and glucuronidation are two major detoxification pathways in humans. In order to characterize possible CYP- and UGT-dependent metabolites of the 2-(4-bromo-2,5-dimethoxy-phenyl)-N-[(2-methoxyphenyl)methyl]ethanamine (25B-NBOMe), a synthetic psychoactive drug, analyses of human liver microsome (HLM) incubates were performed using an ultra-high performance liquid chromatography system coupled with a quadrupole-time of flight mass spectrometry detector (UHPLC-Q-TOF/MS). On-line analyses were performed using a Waters OASIS HLB column (30 x 2.1 mm, 20 µm) for the automatic sample loading and a Waters ACQUITY HSS C18 column (150 x 2 mm, 1.8 µm) for the chromatographic separation. Twenty-one metabolites, consisting of 12 CYP-derived and 9 UGT-derived metabolites, were identified. O-Desmethyl metabolites were the most abundant compounds after the phase I process, which appears to be in accordance with data from previously published NBOMe-intoxication case reports. Although other important metabolic transformations, such as sulfation, acetylation, methylation or glutathione conjugation, were not studied and artefactual metabolites might have been produced during the HLM incubation process, the record of all the metabolite MS spectra in our library should enable us to characterize relevant metabolites of 25B-NBOMe and allow us to detect 25B-MBOMe users. Copyright © 2015 John Wiley & Sons, Ltd.
Gritti, Fabrice; McDonald, Thomas; Gilar, Martin
2015-11-13
The impact of the column hardware volume (≃ 1.7 μL) on the optimum reduced plate heights of a series of short 2.1 mm × 50 mm columns (hold-up volume ≃ 80-90 μL) packed with 1.8 μm HSS-T3, 1.7 μm BEH-C18, 1.7 μm CSH-C18, 1.6 μm CORTECS-C18+, and 1.7 μm BEH-C4 particles was investigated. A rapid and non-invasive method based on the reduction of the system dispersion (to only 0.15 μL(2)) of an I-class Acquity system and on the corrected plate heights (for system dispersion) of five weakly retained n-alkanophenones in RPLC was proposed. Evidence for sample dispersion through the column hardware volume was also revealed from the experimental plot of the peak capacities for smooth linear gradients versus the corrected efficiency of a weakly retained alkanophenone (isocratic runs). The plot is built for a constant gradient steepness irrespective of the applied flow rates (0.01-0.30 mL/min) and column lengths (2, 3, 5, and 10 cm). The volume variance caused by column endfittings and frits was estimated in between 0.1 and 0.7 μL(2) depending on the applied flow rate. After correction for system and hardware dispersion, the minimum reduced plate heights of short (5 cm) and narrow-bore (2.1mm i.d.) beds packed with sub-2 μm fully and superficially porous particles were found close to 1.5 and 0.7, respectively, instead of the classical h values of 2.0 and 1.4 for the whole column assembly. Copyright © 2015 Elsevier B.V. All rights reserved.
Drug screening in medical examiner casework by high-resolution mass spectrometry (UPLC-MSE-TOF).
Rosano, Thomas G; Wood, Michelle; Ihenetu, Kenneth; Swift, Thomas A
2013-10-01
Postmortem drug findings yield important analytical evidence in medical examiner casework, and chromatography coupled with nominal mass spectrometry (MS) serves as the predominant general unknown screening approach. We report screening by ultra performance liquid chromatography (UPLC) coupled with hybrid quadrupole time-of-flight mass spectrometer (MS(E)-TOF), with comparison to previously validated nominal mass UPLC-MS and UPLC-MS-MS methods. UPLC-MS(E)-TOF screening for over 950 toxicologically relevant drugs and metabolites was performed in a full-spectrum (m/z 50-1,000) mode using an MS(E) acquisition of both molecular and fragment ion data at low (6 eV) and ramped (10-40 eV) collision energies. Mass error averaged 1.27 ppm for a large panel of reference drugs and metabolites. The limit of detection by UPLC-MS(E)-TOF ranges from 0.5 to 100 ng/mL and compares closely with UPLC-MS-MS. The influence of column recovery and matrix effect on the limit of detection was demonstrated with ion suppression by matrix components correlating closely with early and late eluting reference analytes. Drug and metabolite findings by UPLC-MS(E)-TOF were compared with UPLC-MS and UPLC-MS-MS analyses of postmortem blood in 300 medical examiner cases. Positive findings by all methods totaled 1,528, with a detection rate of 57% by UPLC-MS, 72% by UPLC-MS-MS and 80% by combined UPLC-MS and UPLC-MS-MS screening. Compared with nominal mass screening methods, UPLC-MS(E)-TOF screening resulted in a 99% detection rate and, in addition, offered the potential for the detection of nontargeted analytes via high-resolution acquisition of molecular and fragment ion data.
Resistance to High-Temperature Oxidation and Wear of Various Ferrous Alloys Used in Rolling Mills
NASA Astrophysics Data System (ADS)
Delaunois, Fabienne; Stanciu, Victor Ioan; Sinnaeve, Mario
2018-03-01
Various materials are commonly used to manufacture work rolls for hot rolling mills, such as ICDP (Indefinite Chill Double Pour) cast irons, high-chromium white cast irons, and high speed steels (HSS). Various chemical compositions and microstructures are studied in order to optimize the in-use behavior of those grades of rolls. In this paper, six grades of ferrous alloys (an ICDP cast iron; an ICDP cast iron enriched in vanadium, niobium, and molybdenum; a HSS; a graphitic HSS; a high-chromium white cast iron (Hi-Cr); and a niobium-molybdenum-doped high-chromium white cast iron) were investigated. High-temperature oxidation tests with gravimetric means at 575 °C in water vapor atmosphere and sliding wear tests were carried out. The oxidation kinetics was followed during oxidation test. The microstructure was observed by optical and scanning electron microscopies. The oxides formed on the surface of the samples were analyzed by XRD and EDS. The thickness of the oxide scales and the mass gain were measured after oxidation test. The results showed that the behavior of all the grades differed. The oxide scale of HSS and HSS-G grades was fine and their friction coefficient was low. The weight gain after oxidation test of HSS was high. Hi-Cr and M-Hi-Cr grades presented highly porous oxide layer and an important increase of the friction coefficient during wear test. ICDP and M-ICDP had intermediate behavior.
Binkhorst, Lisette; Mathijssen, Ron H J; Ghobadi Moghaddam-Helmantel, Inge M; de Bruijn, Peter; van Gelder, Teun; Wiemer, Erik A C; Loos, Walter J
2011-12-15
In view of future pharmacokinetic studies, a highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method has been developed for the simultaneous quantification of tamoxifen and three of its main phase I metabolites in human lithium heparinized plasma. The analytical method has been thoroughly validated in agreement with FDA recommendations. Plasma samples of 200 μl were purified by liquid-liquid extraction with 1 ml n-hexane/isopropanol, after deproteination through addition of 50 μl acetone and 50 μl deuterated internal standards in acetonitrile. Tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen were chromatographically separated on an Acquity UPLC(®) BEH C18 1.7 μm 2.1 mm×100 mm column eluted at a flow-rate of 0.300 ml/min on a gradient of 0.2mM ammonium formate and acetonitrile, both acidified with 0.1% formic acid. The overall run time of the method was 10 min, with elution times of 2.9, 3.0, 4.1 and 4.2 min for endoxifen, 4-hydroxy-tamoxifen, N-desmethyl-tamoxifen and tamoxifen, respectively. Tamoxifen and its metabolites were quantified by triple-quadrupole mass spectrometry in the positive ion electrospray ionization mode. The multiple reaction monitoring transitions were set at 372>72 (m/z) for tamoxifen, 358>58 (m/z) for N-desmethyl-tamoxifen, 388>72 (m/z) for 4-hydroxy-tamoxifen and 374>58 (m/z) for endoxifen. The analytical method was highly sensitive with the lower limit of quantification validated at 5.00 nM for tamoxifen and N-desmethyl-tamoxifen and 0.500 nM for 4-hydroxy-tamoxifen and endoxifen, which is equivalent to 1.86, 1.78, 0.194 and 0.187 ng/ml for tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and endoxifen, respectively. The method was also precise and accurate, with within-run and between-run precisions within 12.0% and accuracy ranging from 89.5 to 105.3%. The method has been applied to samples from a clinical study and cross-validated with a validated LC-MS/MS method in serum. Copyright © 2011 Elsevier B.V. All rights reserved.
Quantification of 21 antihypertensive drugs in serum using UHPLC-MS/MS.
Gundersen, Per Ole M; Helland, Arne; Spigset, Olav; Hegstad, Solfrid
2018-04-28
Poor drug adherence in hypertensive patients can lead to treatment failure and increased cardiovascular morbidity, as well as increased costs to society. An analytical method based on ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MSMS) was developed and validated for use in routine therapeutic drug monitoring (TDM). The method includes 21 antihypertensive drugs or active metabolites from the groups beta blockers (n=5), calcium antagonists (n=5), angiotensin II receptor antagonists (n=4), angiotensin converting enzyme (ACE) inhibitors (n=3) and diuretics (n = 3), in addition to one α1-selective alpha blocker. A 200 µL serum sample was handled automatically using a pipetting robot. Protein precipitation was performed with 600 µL of 1% formic acid in acetonitrile (v:v) and phospholipid removal was carried out using a Waters OSTRO™ 96-well plate. After evaporation and reconstitution the eluent was injected thrice with different inlet and mass spectrometric methods to cover the different physico-chemical properties of the drugs and the variations in therapeutic concentration ranges between drugs. Acquity UPLC BEH C18 (2.1x50mm, 1.7 µm) column equipped with a corresponding pre-column was used for chromatographic separation. For every analyte an isotopically labelled analogue served as internal standard, except for lisinopril where enalaprilat-d5 was used. Accuracies were in the range of -13.7 to 13.2% and intra-day and inter-day precisions in the range of 1.1 to 10.5%. The linearity within the calibration ranges expressed as coefficient of determination was higher than 0.995 for all compounds. Matrix effects and recovery efficiencies were within acceptable limits. The limits of quantitation varied from 0.02 to 10.7 µg/L. The stability of the drugs in serum at different conditions was tested. Diltiazem was not stable at 4-8 °C with up to 23.5 % loss after six days. Degradation of atenolol, irbesartan, bendroflumethiazide, hydrochlorothiazide and diltiazem was observed when stored at 30 °C. The suitability of the method was demonstrated in a routine TDM setting, analysing samples from 127 patients undergoing antihypertensive drug treatment. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yang, Hongliang; Zhao, Hao; Xing, Zhongwen
2017-11-01
For the demand of energy conservation and security improvement, high-strength steel (HSS) is increasingly being used to produce safety related automotive components. However, cross-section distortion occurs easily in bending of HSS tube with rectangular section (RS), affecting the forming precision. HSS BR1500HS tube by rotary draw bending is taken as the study object and a description method of cross-section distortion is proposed in this paper. The influence on cross-section precision of geometric parameters including cross-section position, thickness of tube, bend radius etc. are studied by experiment. Besides, simulation of the rotary draw bending of HSS tube with rectangular section by ABAQUS are carried out and compared to the experiment. The results by simulation agree well with the experiment and show that the cross-section is approximately trapezoidal after distortion; the maximum of distortion exists at 45 ∼ 60° of the bending direction; and the absolute and relative distortion values increase with the decreasing of tube thickness or bending radius. Therefore, the results can provide a reference for the design of geometric parameters of HSS tube with rectangular section in rotary draw bending.
Investigations on Heat Treatment of a High-Speed Steel Roll
NASA Astrophysics Data System (ADS)
Fu, Hanguang; Qu, Yinhu; Xing, Jiandong; Zhi, Xiaohui; Jiang, Zhiqiang; Li, Mingwei; Zhang, Yi
2008-08-01
High-carbon high-speed steels (HSS) are very abrasion-resistant materials primarily due to their high hardness MC-type carbide and high hardness martensitic matrix. The effects of quenching and tempering treatment on the microstructure, mechanical properties, and abrasion resistance of centrifugal casting high-carbon HSS roll were studied. Different microstructures and mechanical properties were obtained after the quenching and tempering temperatures of HSS roll were changed. With air-cooling and sodium silicate solution cooling, when the austenitizing temperature reaches 1273 K, the metallic matrix all transforms into the martensite. Afterwards, the eutectic carbides dissolve into the metallic matrix and their continuous network distribution changes into the broken network. The second hardening temperature of high-carbon HSS roll is around 793 K. No significant changes in tensile strength and elongation percentage are observed unless the tempering temperature is beyond 753 K. The tensile strength increases obviously and the elongation percentage decreases slightly beyond 753 K. However, the tensile strength decreases and the elongation percentage increases when the tempering temperature exceeds 813 K. When the tempering temperature excels 773 K, the impact toughness has a slight decrease. Tempering at 793-813 K, high-carbon HSS roll presents excellent abrasion resistance.
Schistosomiasis and hepatopulmonary syndrome: the role of concomitant liver cirrhosis.
Gonçalves-Macedo, Liana; Lopes, Edmundo Pessoa; Domingues, Ana Lucia Coutinho; Markman, Brivaldo; Mota, Vitor Gomes; Luna, Carlos Feitosa
2017-07-01
Hepatopulmonary syndrome (HPS) is defined as an oxygenation defect induced by intrapulmonary vasodilation in patients with liver disease or portal hypertension. It is investigated in patients with liver cirrhosis and less frequently in those with portal hypertension without liver cirrhosis, as may occur in hepatosplenic schistosomiasis (HSS). To investigate the prevalence of HPS in patients with HSS, and to determine whether the occurrence of HPS is influenced by concomitant cirrhosis. We evaluated patients with HSS with or without concomitant liver cirrhosis. All patients underwent laboratory testing, ultrasound, endoscopy, contrast echocardiography, and arterial blood gas analysis. Of the 121 patients with HSS, 64 were also diagnosed with liver cirrhosis. HPS was diagnosed in 42 patients (35%) and was more frequent among patients with concomitant liver cirrhosis than in those without cirrhosis (42% vs. 26%), but the difference was not significant (p = 0.069). HPS was more common in those with spider naevi, Child-Pugh classes B or C and high model for end stage liver disease (MELD) scores (p < 0.05 each). The prevalence of HPS was 35% in this study. The occurrence of liver cirrhosis concomitantly with HSS may have influenced the frequency of patients presenting with HPS.
Zhou, Liqing; Yang, Aiguo; Liu, Zhihong; Wu, Biao; Sun, Xiujun; Lv, Zhenming; Tian, Ji-Teng; Du, Meirong
2017-02-01
The ark shell Scapharca broughtonii is a commercially important shellfish in China. Alserver's solution (AS), modified Alserver's solution (MAS) and Heparin sodium solution (HSS) are common anticoagulants used for shellfish blood. To observe the immune response mediated by its hemocytes, we challenged in vivo S. broughtonii hemolymph with Vibrio anguillarum and dealt with the following three anticoagulants in vitro: Alserver's solution (AS), modified Alserver's solution (MAS) and Heparin sodium solution (HSS). The methodologies we used were immunostimulation with V. anguillarum, Wright-Giemsa staining, micro-examination, and flow cytometric and hydrolyzing enzyme activity analysis. The results showed that all three types of anticoagulants effectively prevented blood clotting in ark shellfish. The morphology of hemocytes did not significantly change 30 h after anticoagulant treatment, except for the shrinking of hemocytes after administering HSS. The size and permeability of hemocytes changed when treated with the anticoagulants and when stimulated with V. anguillarum. Both alkaline phosphatase (AKP) and acid phosphatase (ACP) in hemocytes and Plasma were measured at different times after they were stimulated with V. anguillarum in HSS and MAS. The AKP enzymatic activity in HSS was somewhat higher than in the MAS anticoagulant, but changes in response to V. anguillarum challenge of enzymatic activity were almost the same in HSS and MAS groups. In conclusion, all three types of anticoagulants may be used for ark shell blood preservation. They all changed the cell-surface characteristics of hemocytes to inhibit clot formation. The AS anticoagulant was appropriate for maintaining white and red cell shapes, while MAS was ideal for retaining throbus cell function. Lastly, HSS was appropriate for maintaining enzymatic activity in hemolymph and function of hemocytes. Following this investigation, we gained insight into the changes in hemolymph characteristic during immune response. Copyright © 2016. Published by Elsevier Ltd.
Árnason, Úlfur
2017-09-05
The substantiality of the Out of Africa hypothesis was addressed in the light of recent genomic analysis of extant humans (Homo sapiens sapiens, Hss) and progress in Neanderthal palaeontology. The examination lent no support to the commonly assumed Out of Africa scenario but favoured instead a Eurasian divergence between Neanderthals and Hss (the Askur/Embla hypothesis) and an Out of Asia/Eurasia hypothesis according to which all other parts of the world were colonized by Hss migrations from Asia. The examination suggested furthermore that the ancestors of extant KhoeSan and Mbuti composed the first Hss dispersal(s) into Africa and that the ancestors of Yoruba made up a later wave into the same continent. The conclusions constitute a change in paradigm for the study of human evolution. Copyright © 2017. Published by Elsevier B.V.
Sleep Disorders Among Holocaust Survivors: A Review of Selected Publications.
Lurie, Ido
2017-09-01
After World War II, traumatic after effects often caused persistent sleep disorders for Holocaust survivors (HSs). This is a review of studies reporting on sleep disturbances and nightmares (as primary or secondary outcomes) among HSs between 1939 and 2015, conducted in various countries and contexts (clinical settings, pension claims, community surveys, sleep laboratories). Most studies revealed various sleep disturbances among HSs. Some studies found those disturbances in the absence of clinical disorders. Both men and women reported similar frequencies of sleep disturbances, although posttraumatic stress disorder and depression were more frequent in women. Sleep laboratory studies provided the single most direct and detailed sources of information. Findings included a) long-standing changes in sleep architecture, for example, decreased rapid eye movement (REM) sleep, and b) contrasting patterns of dreaming and recall among better versus poorly adjusted survivors. These results are of importance to both HSs and their families and for medical and mental health professionals.
Gonzalo, Jed D; Baxley, Elizabeth; Borkan, Jeffrey; Dekhtyar, Michael; Hawkins, Richard; Lawson, Luan; Starr, Stephanie R; Skochelak, Susan
2017-01-01
Educators, policy makers, and health systems leaders are calling for significant reform of undergraduate medical education (UME) and graduate medical education (GME) programs to meet the evolving needs of the health care system. Nationally, several schools have initiated innovative curricula in both classroom and workplace learning experiences to promote education in health systems science (HSS), which includes topics such as value-based care, health system improvement, and population and public health. However, the successful implementation of HSS curricula across schools is challenged by issues of curriculum design, assessment, culture, and accreditation, among others. In this report of a working conference using thematic analysis of workshop recommendations and experiences from 11 U.S. medical schools, the authors describe seven priority areas for the successful integration and sustainment of HSS in educational programs, and associated challenges and potential solutions. In 2015, following regular HSS workgroup phone calls and an Accelerating Change in Medical Education consortium-wide meeting, the authors identified the priority areas: partner with licensing, certifying, and accrediting bodies; develop comprehensive, standardized, and integrated curricula; develop, standardize, and align assessments; improve the UME to GME transition; enhance teachers' knowledge and skills, and incentives for teachers; demonstrate value added to the health system; and address the hidden curriculum. These priority areas and their potential solutions can be used by individual schools and HSS education collaboratives to further outline and delineate the steps needed to create, deliver, study, and sustain effective HSS curricula with an eye toward integration with the basic and clinical sciences curricula.
Vyas, S; Enockson, C; Hernandez, L; Valentino, L A
2014-01-01
The phenotypic variability in haemophilia is well documented; however, the biological basis beyond factor VIII and IX activities to explain the differing clinical pictures of the disease remains unclear. It has therefore been of interest to explore other modulators of the disease's variability. Furthermore, a scoring system that reflects the multiple facets of haemophilia symptoms would be useful to compare patients via a comprehensive assessment tool. To this end, Schulman et al., created a measure known as the Haemophilia Severity Score (HSS) as one way to compare phenotypic severity. The aim of this study was to document the differing symptomatology of haemophilia patients using the HSS. Clinical data for 178 haemophilia patients without inhibitors were reviewed and annual incidence of haemarthrosis, orthopaedic joint scores and annual factor usage calculated. Each parameter was then entered into the formula to create the HSS for haemophilia A and B patients with mild, moderate and severe factor deficiencies. Variability in the HSS for patients with the same baseline level of factor was observed for all three deficiency levels and both haemophilia types. In addition, we found that moderate and severe haemophilic B patients tended to have more morbidity based on the above calculations than the haemophilic A counterparts. The HSS is a comprehensive tool that allows for easy numerical comparison of haemophilic patients and elucidates the variable clinical presentation of the disease. The HSS could be used to stratify patients via other possible modulators of haemophilia and discover other aetiologies of the disease. © 2013 John Wiley & Sons Ltd.
Oortwijn, Wija; Sampietro-Colom, Laura; Habens, Fay; Trowman, Rebecca
2018-06-11
For many years, several health technology assessment (HTA) agencies scanned the horizon to identify health technologies that were safe, effective and offer value for money. However, there is limited evidence regarding its impact. The role of horizon scanning in preparing health systems for the uptake of new and emerging health technologies was discussed during the 2018 HTA International (HTAi) Global Policy Forum Meeting. Reflection of the discussion between seventy-two senior representatives from for-profit, not-for-profit organizations, and HTAi leadership. It was informed by a background paper, and presentations from four invited experts and seventeen Policy Forum members. Current horizon scanning systems (HSS) mainly identify health technologies in the late stage of development, aiming to inform topic selection for HTA. Areas for improvement included the need for a clearer definition of the end user(s), purpose, scope, and focus of HSS, the long-term full health system effects, including all relevant stakeholders as early as possible, and considering smart data systems and international collaboration to improve HSS's efficiency. The way in which HSS could be further optimized and better shaped to prepare health systems was also discussed and good practice examples were presented. HSS have not yet reached their full potential in preparing health systems. To improve the current situation, the HTA community could act as convenors, bringing together all relevant stakeholders and providing the information that decision makers need. This would require a new, more integrative approach to define and use HSS and HTA, and requires new skills.
OCCURRENCE OF HIGH-SPEED SOLAR WIND STREAMS OVER THE GRAND MODERN MAXIMUM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mursula, K.; Holappa, L.; Lukianova, R., E-mail: kalevi.mursula@oulu.fi
2015-03-01
In the declining phase of the solar cycle (SC), when the new-polarity fields of the solar poles are strengthened by the transport of same-signed magnetic flux from lower latitudes, the polar coronal holes expand and form non-axisymmetric extensions toward the solar equator. These extensions enhance the occurrence of high-speed solar wind (SW) streams (HSS) and related co-rotating interaction regions in the low-latitude heliosphere, and cause moderate, recurrent geomagnetic activity (GA) in the near-Earth space. Here, using a novel definition of GA at high (polar cap) latitudes and the longest record of magnetic observations at a polar cap station, we calculatemore » the annually averaged SW speeds as proxies for the effective annual occurrence of HSS over the whole Grand Modern Maximum (GMM) from 1920s onward. We find that a period of high annual speeds (frequent occurrence of HSS) occurs in the declining phase of each of SCs 16-23. For most cycles the HSS activity clearly reaches a maximum in one year, suggesting that typically only one strong activation leading to a coronal hole extension is responsible for the HSS maximum. We find that the most persistent HSS activity occurred in the declining phase of SC 18. This suggests that cycle 19, which marks the sunspot maximum period of the GMM, was preceded by exceptionally strong polar fields during the previous sunspot minimum. This gives interesting support for the validity of solar dynamo theory during this dramatic period of solar magnetism.« less
Baxley, Elizabeth G; Lawson, Luan; Garrison, Herbert G; Walsh, Danielle; Lazorick, Suzanne; Lake, Donna; Higginson, Jason
2016-12-01
Although efforts to integrate health systems science (HSS) topics, such as patient safety, quality improvement (QI), interprofessionalism, and population health, into health professions curricula are increasing, the rate of change has been slow. The Teachers of Quality Academy (TQA), Brody School of Medicine at East Carolina University, was established in January 2014 with the dual goal of preparing faculty to lead frontline clinical transformation while becoming proficient in the pedagogy and curriculum design necessary to prepare students in HSS competencies. The TQA included the completion of the Institute for Healthcare Improvement Open School Basic Certificate in Quality and Safety; participation in six 2-day learning sessions on key HSS topics; completion of a QI project; and participation in three online graduate courses. Twenty-seven faculty from four health science programs completed the program. All completed their QI projects. Nineteen (70%) have been formally engaged in the design and delivery of the medical student curriculum in HSS. Early into their training, TQA participants began to apply new knowledge and skills in HSS to the development of educational initiatives beyond the medical student curriculum. Important next steps for TQA participants and program planners include further incorporation as faculty advisors and contributors to the full implementation of the longitudinal HSS curriculum; expanded involvement with the Leaders in Innovative Care Scholars student leadership distinction track; continued in-depth evaluation of the impact of TQA participation on patient care, teaching, and role modeling; and the recruitment of the next cohort of TQA participants.
Method and system to reclaim functional sites on a sorbent contaminated by heat stable salts
Krutka, Holly; Sjostrom, Sharon; Morris, William J.
2016-03-08
The objective of this invention is to develop a method to reclaim functional sites on a CO.sub.2 sorbent that have reacted with an acid gas (other than CO.sub.2) to form heat stable salts (HSS). HSS are a significant concern for dry sorbent based CO.sub.2 capture because over time the buildup of HSS will reduce the overall functionality of the CO.sub.2 sorbent. A chemical treatment can remove the non-CO.sub.2 acid gas and reclaim functional sites that can then be used for further CO.sub.2 adsorption.
NASA Astrophysics Data System (ADS)
Chun, Eun-Joon; Lim, Sung-Sang; Kim, Young-Tae; Nam, Ki-Sung; Kim, Young-Min; Park, Young-Whan; Murugan, Siva Prasad; Park, Yeong-Do
2018-03-01
Resistance nut projection weldability of Al-Si coated hot stamped steel (HSS) was investigated under the viewpoint of weldable current range and joint strength (pull-out load). The microstructural inhomogeneities in the welds were also studied in order to elucidate the factors affecting the joint strength of the welds. The weldability of the given Al-Si coated HSS was compared with the weldability of an identical HSS without the Al-Si coating (Al-Si coating was polished out) and Zn coated dual phase steel. The weldable current range of Al-Si coated HSS was found to be narrower than that of the other materials. Furthermore, the average pull-out load within the weldable current range of the Al-Si coated HSS was the lowest among the three materials. The reason for poor weld mechanical property of the Al-Si coated hot-stamped steel was attributed to the microstructural inhomogeneities such as unmixed Al-Si coating layer at the edge of the nugget and the second phase Fe3(Al, Si) intermetallic compound. The formation of Fe3(Al, Si) phase was attributed to the solidification segregation of Al and Si during the weld solidification and was confirmed with the numerical analysis of solidification segregation.
Tan, Wenbing; Xi, Beidou; Wang, Guoan; Jiang, Jie; He, Xiaosong; Mao, Xuhui; Gao, Rutai; Huang, Caihong; Zhang, Hui; Li, Dan; Jia, Yufu; Yuan, Ying; Zhao, Xinyu
2017-03-21
The electron transfer capacities (ETCs) of soil humic substances (HSs) are linked to the type and abundance of redox-active functional moieties in their structure. Natural temperature can affect the chemical structure of natural organic matter by regulating their oxidative transformation and degradation in soil. However, it is unclear if there is a direct correlation between ETC of soil HS and mean annual temperature. In this study, we assess the response of the electron-accepting and -donating capacities (EAC and EDC) of soil HSs to temperature by analyzing HSs extracted from soil set along glacial-interglacial cycles through loess-palaeosol sequences and along natural temperature gradients through latitude and altitude transects. We show that the EAC and EDC of soil HSs increase and decrease, respectively, with increasing temperature. Increased temperature facilitates the prevalence of oxidative degradation and transformation of HS in soils, thus potentially promoting the preferentially oxidative degradation of phenol moieties of HS or the oxidative transformation of electron-donating phenol moieties to electron-accepting quinone moieties in the HS structure. Consequently, the EAC and EDC of HSs in soil increase and decrease, respectively. The results of this study could help to understand biogeochemical processes, wherein the redox functionality of soil organic matter is involved in the context of increasing temperature.
The GAVI Alliance and the ‘Gates approach’ to health system strengthening
Storeng, Katerini T.
2014-01-01
Lauded for getting specific health issues onto national and international agendas and for their potential to improve value for money and outcomes, public-private global health initiatives (GHIs) have come to dominate global health governance. Yet, they have also been criticised for their negative impact on country health systems. In response, disease-specific GHIs have, somewhat paradoxically, appropriated the aim of health system strengthening (HSS). This article critically analyses this development through an ethnographic case study of the GAVI Alliance, which funds vaccines in poor countries. Despite GAVI's self-proclaimed ‘single-minded’ focus on vaccines, HSS support is fronted as a key principle of GAVI's mission. Yet, its meaning remains unclear and contested understandings of the health systems agenda abound, reflecting competing public health ideologies and professional pressures within the global health field. Contrary to broader conceptualisations of HSS that emphasise social and political dimensions, GAVI's HSS support has become emblematic of the so-called ‘Gates approach’ to global health, focused on targeted technical solutions with clear, measurable outcomes. In spite of adopting rhetoric supportive of ‘holistic’ health systems, GHIs like GAVI have come to capture the global debate about HSS in favour of their disease-specific approach and ethos. PMID:25156323
Marmet, Cynthia; Actis-Goretta, Lucas; Renouf, Mathieu; Giuffrida, Francesca
2014-01-01
Chlorogenic acids and derivatives like phenolic acids are potentially bioactive phenolics, which are commonly found in many foods. Once absorbed, chlorogenic and phenolic acids are highly metabolized by the intestine and the liver, producing glucuronidated and/or sulphated compounds. These metabolites were analyzed in human plasma using a validated liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) method. After protein precipitation, phenolic acids and their metabolites were extracted by using ethanol and chromatographic separation was achieved by reversed-phase using an Acquity UPLC BEH C18 column combined with a gradient elution system using 1% acetic acid aqueous solution and 1% acetic acid with 100% acetonitrile. The method was able to quantify 56 different compounds including 24 phenolic acids, 4 lactones, 15 sulfates and 13 glucuronides metabolites between 5 and 1000nM in plasma for most of them, except for m-dihydrocoumaric acid, 5-ferulloylquinic-glucuronide, 4-methoxycinnamic acid, 3-phenylpropionic acid, 3-(4-methoxyphenyl)propionic acid (25 to 1000nM) and p-dihydrocoumaric acid (50-1000nM). Values of repeatability and intermediate reproducibility were below 15% of deviation in general, and maximum 20% for the lowest concentrations. The validated method was successfully applied to quantify phenolic acids and their metabolites in plasma obtained after oral ingestion of soluble coffee. In conclusion, the developed and validated method is proved to be very sensitive, accurate and precise for the quantification of these possible dietary phenols. Copyright © 2013 Elsevier B.V. All rights reserved.
Rodríguez-Gómez, R; Zafra-Gómez, A; Camino-Sánchez, F J; Ballesteros, O; Navalón, A
2014-07-04
In the present work, two specific, accurate and sensitive methods for the determination of endocrine disrupting chemicals (EDCs) in human breast milk are developed and validated. Bisphenol A and its main chlorinated derivatives, five benzophenone-UV filters and four parabens were selected as target analytes. The method involves a stir-bar sorptive extraction (SBSE) procedure followed by a solvent desorption prior to GC-MS/MS or UHPLC-MS/MS analysis. A derivatization step is also necessary when GC analysis is performed. The GC column used was a capillary HP-5MS with a run time of 26min. For UHPLC analysis, the stationary phase was a non-polar Acquity UPLC(®) BEH C18 column and the run time was 10min. In both cases, the analytes were detected and quantified using a triple quadrupole mass spectrometer (QqQ). Quality parameters such as linearity, accuracy (trueness and precision), sensitivity and selectivity were examined and yielded good results. The limits of quantification (LOQs) ranged from 0.3 to 5.0ngmL(-1) for GC and from 0.2 to 1.0ngmL(-1) for LC. The relative standard deviation (RSD) was lower than 15% and the recoveries ranged from 92 to 114% in all cases, being slightly unfavorable the results obtained with LC. The methods were satisfactorily applied for the determination of target compounds in human milk samples from 10 randomly selected women. Copyright © 2014 Elsevier B.V. All rights reserved.
Rathore, Atul S; Sathiyanarayanan, L; Deshpande, Shreekant; Mahadik, Kakasaheb R
2016-11-01
A rapid and sensitive method for the extraction and determination of four major polyphenolic components in Euphoria longana Lam. seeds is presented for the first time based on matrix solid-phase dispersion extraction followed by ultra high performance liquid chromatography with hybrid triple quadrupole linear ion trap mass spectrometry. Matrix solid-phase dispersion method was designed for the extraction of Euphoria longana seed constituents and compared with microwave-assisted extraction and ultrasonic-assisted extraction methods. An Ultra high performance liquid chromatography with hybrid triple quadrupole linear ion-trap mass spectrometry method was developed for quantitative analysis in multiple-reaction monitoring mode in negative electrospray ionization. The chromatographic separation was accomplished using an ACQUITY UPLC BEH C 18 (2.1 mm × 50 mm, 1.7 μm) column with gradient elution of 0.1% aqueous formic acid and 0.1% formic acid in acetonitrile. The developed method was validated with acceptable linearity (r 2 > 0.999), precision (RSD ≤ 2.22%) and recovery (RSD ≤ 2.35%). The results indicated that matrix solid-phase dispersion produced comparable extraction efficiency compared with other methods nevertheless was more convenient and time-saving with reduced requirements on sample and solvent volumes. The proposed method is rapid and sensitive in providing a promising alternative for extraction and comprehensive determination of active components for quality control of Euphoria longana products. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Daping; Wu, Lei; Chow, Diana S-L; Tam, Vincent H; Rios, Danielle R
2016-01-05
The determination of dopamine facilitates better understanding of the complex brain disorders in the central nervous system and the regulation of endocrine system, cardiovascular functions and renal functions in the periphery. The purpose of this study was to develop a highly sensitive and reliable assay for the quantification of dopamine in human neonate plasma. Dopamine was extracted from human plasma by strong cation exchange (SCX) solid phase extraction (SPE), and subsequently derivatized with propionic anhydride. The derivatized analyte was separated by a Waters Acquity UPLC BEH C18 column using gradient elution at 0.4 ml/min with mobile phases A (0.2% formic acid in water [v/v]) and B (MeOH-ACN [v/v, 30:70]). Analysis was performed under positive electrospray ionization tandem mass spectrometer (ESI-MS/MS) in the multiple reaction monitoring (MRM) mode. The stable and relatively non-polar nature of the derivatized analyte enables reliable quantification of dopamine in the range of 10-1000 pg/ml using 200 μl of plasma sample. The method was validated with intra-day and inter-day precision less than 7%, and the intra-day and inter-day accuracy of 91.9-101.9% and 92.3-102.6%, respectively. The validated assay was applied to quantify dopamine levels in two preterm neonate plasma samples. In conclusion, a sensitive and selective LC-MS/MS method has been developed and validated, and successfully used for the determination of plasma dopamine levels in preterm neonates. Copyright © 2015 Elsevier B.V. All rights reserved.
Zlatković, Milica; Jovanović, Miodrag; Djordjević, Dragana; Vucinić, Slavica
2010-09-01
Analysis of organophosphosphorus compounds and their metabolites in a biological material includes the use of numerous methods, covering both preparation of samples for analysis and their identification that is considered to be very complex. Low concentrations monitoring requires implementation of highly sensitive analytical techniques. The aim of this study was to develop and validate an original and sensitive method for the detection and quantitation of organophosphorus pesticides (dimethoate, diazinon, malathion and malaoxon) in human biological matrices (serum, urine). This method was based on a solid-phase extraction procedure, a chromatographic separation using an ACQUITY UPLC HSST3 column and mass spectrometric detection in the positive ion mode. Mobile phase: was consited of Solvent A (5 mM ammonium formate pH 3.0) and Solvent B (0.1% acetic formate in methanol), in a linear gradient (constant flow-rate 0.3 mL/min). The standard curve was linear in the range of 0.05-5.00 mg/L for malathion and malaoxon, 0.10-5.00 mg/L for dimethoate and 0.05-2.50 mg/L for diazinon. The correlation coefficient was r > or = 0.99. Extraction recoveries were satisfactory and ranged between 90-99%. The limits of detection (LOD) was between 0.007-0.07 mg/L and the limits of quantitation (LOQ) ranged between 0.022-0.085 mg/L. Intra- and interassay precision and accuracy were satisfactory for all of the pesticides analyzed. The method of liquid chromatography-mass spectrometry is simple, accurate, and useful for the determination of organophosphorus pesticides in both clinical and forensic toxicology.
A Nucleotide-Driven Switch Regulates Flanking DNA Length Sensing by a Dimeric Chromatin Remodeler
Leonard, John D.; Narlikar, Geeta J.
2015-01-01
SUMMARY The ATP-dependent chromatin assembly factor (ACF) is a dimeric motor that spaces nucleosomes to promote formation of silent chromatin. Two copies of its ATPase subunit SNF2h bind opposite sides of a nucleosome, but how these protomers avoid competition is unknown. SNF2h senses the length of DNA flanking a nucleosome via its HAND-SANT-SLIDE (HSS) domain, yet it is unclear how this interaction enhances remodeling. Using covalently connected SNF2h dimers we show that dimerization accelerates remodeling and that the HSS contributes to communication between protomers. We further identify a nucleotide-dependent conformational change in SNF2h. In one conformation the HSS binds flanking DNA, and in another conformation the HSS engages the nucleosome core. Based on these results, we propose a model in which DNA length sensing and translocation are performed by two distinct conformational states of SNF2h. Such separation of function suggests that these activities could be independently regulated to affect remodeling outcomes. PMID:25684208
Hofmeister series salts enhance purification of plasmid DNA by non-ionic detergents
Lezin, George; Kuehn, Michael R.; Brunelli, Luca
2011-01-01
Ion-exchange chromatography is the standard technique used for plasmid DNA purification, an essential molecular biology procedure. Non-ionic detergents (NIDs) have been used for plasmid DNA purification, but it is unclear whether Hofmeister series salts (HSS) change the solubility and phase separation properties of specific NIDs, enhancing plasmid DNA purification. After scaling-up NID-mediated plasmid DNA isolation, we established that NIDs in HSS solutions minimize plasmid DNA contamination with protein. In addition, large-scale NID/HSS solutions eliminated LPS contamination of plasmid DNA more effectively than Qiagen ion-exchange columns. Large-scale NID isolation/NID purification generated increased yields of high quality DNA compared to alkali isolation/column purification. This work characterizes how HSS enhance NID-mediated plasmid DNA purification, and demonstrates that NID phase transition is not necessary for LPS removal from plasmid DNA. Specific NIDs such as IGEPAL CA-520 can be utilized for rapid, inexpensive and efficient laboratory-based large-scale plasmid DNA purification, outperforming Qiagen-based column procedures. PMID:21351074
Minge, Daniel; Senkov, Oleg; Kaushik, Rahul; Herde, Michel K.; Tikhobrazova, Olga; Wulff, Andreas B.; Mironov, Andrey; van Kuppevelt, Toin H.; Oosterhof, Arie; Kochlamazashvili, Gaga
2017-01-01
Abstract Heparan sulfate (HS) proteoglycans represent a major component of the extracellular matrix and are critical for brain development. However, their function in the mature brain remains to be characterized. Here, acute enzymatic digestion of HS side chains was used to uncover how HSs support hippocampal function in vitro and in vivo. We found that long-term potentiation (LTP) of synaptic transmission at CA3–CA1 Schaffer collateral synapses was impaired after removal of highly sulfated HSs with heparinase 1. This reduction was associated with decreased Ca2+ influx during LTP induction, which was the consequence of a reduced excitability of CA1 pyramidal neurons. At the subcellular level, heparinase treatment resulted in reorganization of the distal axon initial segment, as detected by a reduction in ankyrin G expression. In vivo, digestion of HSs impaired context discrimination in a fear conditioning paradigm and oscillatory network activity in the low theta band after fear conditioning. Thus, HSs maintain neuronal excitability and, as a consequence, support synaptic plasticity and learning. PMID:28119345
Chen, Kai; Yao, Qiang; Sun, Ju; He, Zhi-Fei; Yao, Lan; Liu, Zhi-Yong
2016-01-01
In recent years, China's healthcare reforms and related studies have drawn particular global attention. The main objective of this study is to evaluate quantitatively the publication trends and collaboration performance of China in healthcare science and services (HSS) research. Scientometric methods and visualization technology were used to survey the growth and development trends of HSS research based on the Web of Science publications during the past 15 years. China's international publications on HSS research increased rapidly compared to those of the global HSS and Chinese scientific studies. Growth trends indicate that collaboration among countries, institutions and authors has also increased. China's leading partners were all developed countries, such as the US, the UK, Australia and Canada, which have contributed to the majority of the joint publications. The academic impact of publications involving partners from European and American countries was relatively higher than those involving partners from Asian countries. Prominent institutions were universities that could be primarily classified into two groups, namely, Mainland China on the one hand and Hong Kong universities and foreign universities on the other. The most prominent actors were elite institutions, such as Peking University, Fudan University, Chinese University of Hong Kong, University of Hong Kong. The papers published by the Chinese Ministry of Health had relatively high academic impact, whereas those published by Mainland China universities alone had a lower academic impact compared to foreign cooperation papers. Issues related to the Chinese healthcare reform, priority diseases (e.g., breast cancer, HIV/AIDS, tuberculosis, etc.), health systems performance, quality of life and measurement tools, aging problems and research methods have been the most popular HSS topics in China in recent years. Despite the extensive achievement of the Chinese HSS reforms and research, gaps and challenges remain to be addressed, including those related to health insurance and the effects of the evaluation of essential medicine systems, human resources training and allocation in the health sector, government hospitals reforms and health services systems remodeling. These findings could help scholars and decision-makers understand the current status and likely future trends of the Chinese HSS research, and help them select the most appropriate collaboration partners and policies.
NASA Astrophysics Data System (ADS)
George, Chandramohan; Genovese, Alessandro; Qiao, Fen; Korobchevskaya, Kseniya; Comin, Alberto; Falqui, Andrea; Marras, Sergio; Roig, Anna; Zhang, Yang; Krahne, Roman; Manna, Liberato
2011-11-01
We report here a simple synthetic route to Au-FexOy heterostructures in which spinel ferrite (FexOy) grows as a nanorod on a spherical gold (Au) seed. The large red shift in the plasmon resonance in the heterostructures could be explained by a dielectric effect (although we could not entirely exclude a contribution due to electron transfer from Au to defect states at the Au-FexOy interface), while the magnetic properties of the Au-FexOy heterostructures were basically the same as those of the corresponding nanocrystals after Au leaching. In films of Au-FexOy heterostructures the electrical conductivity appeared to be mediated by the Au domains.We report here a simple synthetic route to Au-FexOy heterostructures in which spinel ferrite (FexOy) grows as a nanorod on a spherical gold (Au) seed. The large red shift in the plasmon resonance in the heterostructures could be explained by a dielectric effect (although we could not entirely exclude a contribution due to electron transfer from Au to defect states at the Au-FexOy interface), while the magnetic properties of the Au-FexOy heterostructures were basically the same as those of the corresponding nanocrystals after Au leaching. In films of Au-FexOy heterostructures the electrical conductivity appeared to be mediated by the Au domains. Electronic supplementary information (ESI) available: TEM/HRTEM images of (i) aliquots at the earliest stages of the growth of Au-FexOy HSs; (ii) Au-FexOy HSs synthesized at low DDAB concentrations; (iii) spherical iron oxide nanocrystals synthesized under the same conditions as the HSs, but in the absence of Au seeds; (iv) Au-FexOy urchin like nanostructures, also after attempts to leach out Au; (v) Au-FexOy HSs after treatment with hydrazine; (vi) FexOy HSs after Au leaching from Au-FexOy HSs; additional optical absorption spectra; additional I-V curves, also from films made of Au-FexOy dumbbells; and additional SEM images; vii) X-ray diffraction (XRD) pattern of a sample of Au-FexOy HSs. See DOI: 10.1039/c1nr10768b
Risso-Gill, Isabelle; McKee, Martin; Coker, Richard; Piot, Peter; Legido-Quigley, Helena
2014-07-01
Myanmar has undergone a remarkable political transformation in the last 2 years, with its leadership voluntarily transitioning from an isolated military regime to a quasi-civilian government intent on re-engaging with the international community. Decades of underinvestment have left the country underdeveloped with a fragile health system and poor health outcomes. International aid agencies have found engagement with the Myanmar government difficult but this is changing rapidly and it is opportune to consider how Myanmar can engage with the global health system strengthening (HSS) agenda. Nineteen semi-structured, face-to-face interviews were conducted with representatives from international agencies working in Myanmar to capture their perspectives on HSS following political reform. They explored their perceptions of HSS and the opportunities for implementation. Participants reported challenges in engaging with government, reflecting the disharmony between actors, economic sanctions and barriers to service delivery due to health system weaknesses and bureaucracy. Weaknesses included human resources, data and medical products/infrastructure and logistical challenges. Agencies had mixed views of health system finance and governance, identifying problems and also some positive aspects. There is little consensus on how HSS should be approached in Myanmar, but much interest in collaborating to achieve it. Despite myriad challenges and concerns, participants were generally positive about the recent political changes, and remain optimistic as they engage in HSS activities with the government.
Rosas-Hernandez, Hector; Cuevas, Elvis; Escudero-Lourdes, Claudia; Lantz, Susan M; Sturdivant, Nasya M; Imam, Syed Z; Sarkar, Sumit; Slikker, William; Paule, Merle G; Balachandran, Kartik; Ali, Syed F
2018-04-13
Traumatic brain injury (TBI) occurs when external mechanical forces induce brain damage as result of impact, penetration or rapid acceleration/deceleration that causes deformation of brain tissue. Depending on its severity, TBI can be classified as mild, moderate or severe and can lead to blood-brain barrier (BBB) dysfunction. In the present study, we evaluated the effects of uniaxial high-speed stretch (HSS) at 0, 5, 10 and 15% on a pure culture of primary rat brain endothelial cells as an in vitro model of TBI to the BBB. LDH release, viability and apoptosis analysis, expression of tight junction proteins and endothelial permeability were evaluated 24 h after a single stretch episode. HSS slightly increased cell death and apoptosis at 10 and 15%, while LDH release was increased only at 15% stretch. Occludin expression was increased at 10% stretch, while claudin-5 expression was increased at 5% stretch, which also decreased the endothelial permeability. In summary, 15% HSS induced low levels of cell death, consistent with mild TBI and very low percentages of HSS (5%) enhanced the BBB properties, promoting the formation of a stronger barrier. These data support the use of 15% HSS as valuable tool in the study of mild TBI to the BBB in vitro. Published by Elsevier B.V.
Reanalysis in Adult Heritage Language: New Evidence in Support of Attrition
ERIC Educational Resources Information Center
Polinsky, Maria
2011-01-01
This study presents and analyzes the comprehension of relative clauses in child and adult speakers of Russian, comparing monolingual controls with Russian heritage speakers (HSs) who are English-dominant. Monolingual and bilingual children demonstrate full adultlike mastery of relative clauses. Adult HSs, however, are significantly different from…
An Engineering Student's Guide to the Humanities & Social Sciences.
ERIC Educational Resources Information Center
Association of American Colleges, Washington, DC.
Undergraduate engineering students and their advisors are provided with a handbook to help improve the quality and coherence of the humanities and social sciences (H&SS) component of undergraduate engineering education (fostering more purposeful H&SS course selection). The first of this handbook's three sections has an engineering major…
Effect of Sex on Perceived Support and Burnout in University Students
ERIC Educational Resources Information Center
Weckwerth, Amanda C.; Flynn, Deborah M.
2006-01-01
Sex differences in the experience of social support and frequency of burnout were examined in university students from a small Northern Ontario University. An altered version of the Maslach Burnout Inventory Human Services Survey (MBI-HSS) (Maslach & Jackson, 1996) termed the AMBI-HSS, and the Social Provisions Scale (SPS) (Cutrona &…
Minge, Daniel; Senkov, Oleg; Kaushik, Rahul; Herde, Michel K; Tikhobrazova, Olga; Wulff, Andreas B; Mironov, Andrey; van Kuppevelt, Toin H; Oosterhof, Arie; Kochlamazashvili, Gaga; Dityatev, Alexander; Henneberger, Christian
2017-02-01
Heparan sulfate (HS) proteoglycans represent a major component of the extracellular matrix and are critical for brain development. However, their function in the mature brain remains to be characterized. Here, acute enzymatic digestion of HS side chains was used to uncover how HSs support hippocampal function in vitro and in vivo. We found that long-term potentiation (LTP) of synaptic transmission at CA3-CA1 Schaffer collateral synapses was impaired after removal of highly sulfated HSs with heparinase 1. This reduction was associated with decreased Ca2+ influx during LTP induction, which was the consequence of a reduced excitability of CA1 pyramidal neurons. At the subcellular level, heparinase treatment resulted in reorganization of the distal axon initial segment, as detected by a reduction in ankyrin G expression. In vivo, digestion of HSs impaired context discrimination in a fear conditioning paradigm and oscillatory network activity in the low theta band after fear conditioning. Thus, HSs maintain neuronal excitability and, as a consequence, support synaptic plasticity and learning. © The Author 2017. Published by Oxford University Press.
Ghysels, Pieter; Li, Xiaoye S.; Rouet, Francois -Henry; ...
2016-10-27
Here, we present a sparse linear system solver that is based on a multifrontal variant of Gaussian elimination and exploits low-rank approximation of the resulting dense frontal matrices. We use hierarchically semiseparable (HSS) matrices, which have low-rank off-diagonal blocks, to approximate the frontal matrices. For HSS matrix construction, a randomized sampling algorithm is used together with interpolative decompositions. The combination of the randomized compression with a fast ULV HSS factoriz ation leads to a solver with lower computational complexity than the standard multifrontal method for many applications, resulting in speedups up to 7 fold for problems in our test suite.more » The implementation targets many-core systems by using task parallelism with dynamic runtime scheduling. Numerical experiments show performance improvements over state-of-the-art sparse direct solvers. The implementation achieves high performance and good scalability on a range of modern shared memory parallel systems, including the Intel Xeon Phi (MIC). The code is part of a software package called STRUMPACK - STRUctured Matrices PACKage, which also has a distributed memory component for dense rank-structured matrices.« less
Transition from amplitude to oscillation death in a network of oscillators
NASA Astrophysics Data System (ADS)
Nandan, Mauparna; Hens, C. R.; Pal, Pinaki; Dana, Syamal K.
2014-12-01
We report a transition from a homogeneous steady state (HSS) to inhomogeneous steady states (IHSSs) in a network of globally coupled identical oscillators. We perturb a synchronized population of oscillators in the network with a few local negative or repulsive mean field links. The whole population splits into two clusters for a certain number of repulsive mean field links and a range of coupling strength. For further increase of the strength of interaction, these clusters collapse into a HSS followed by a transition to IHSSs where all the oscillators populate either of the two stable steady states. We analytically determine the origin of HSS and its transition to IHSS in relation to the number of repulsive mean-field links and the strength of interaction using a reductionism approach to the model network. We verify the results with numerical examples of the paradigmatic Landau-Stuart limit cycle system and the chaotic Rössler oscillator as dynamical nodes. During the transition from HSS to IHSSs, the network follows the Turing type symmetry breaking pitchfork or transcritical bifurcation depending upon the system dynamics.
Transition from amplitude to oscillation death in a network of oscillators
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nandan, Mauparna; Department of Mathematics, National Institute of Technology, Durgapur 713209; Hens, C. R.
2014-12-01
We report a transition from a homogeneous steady state (HSS) to inhomogeneous steady states (IHSSs) in a network of globally coupled identical oscillators. We perturb a synchronized population of oscillators in the network with a few local negative or repulsive mean field links. The whole population splits into two clusters for a certain number of repulsive mean field links and a range of coupling strength. For further increase of the strength of interaction, these clusters collapse into a HSS followed by a transition to IHSSs where all the oscillators populate either of the two stable steady states. We analytically determinemore » the origin of HSS and its transition to IHSS in relation to the number of repulsive mean-field links and the strength of interaction using a reductionism approach to the model network. We verify the results with numerical examples of the paradigmatic Landau-Stuart limit cycle system and the chaotic Rössler oscillator as dynamical nodes. During the transition from HSS to IHSSs, the network follows the Turing type symmetry breaking pitchfork or transcritical bifurcation depending upon the system dynamics.« less
Malignant melanoma in Chile: different site distribution between private and state patients.
Zemelman, Viviana B; Valenzuela, Carlos Y; Sazunic, Ivo; Araya, Irene
2014-01-01
The body site location of primary Malignant Melanoma (MM) has been correlated with prognosis and survival. Ethnic, genetics, sun exposure factors are related to the anatomical distribution of MM. Low and high socioeconomic strata in Chile differ in ethnic, genetic and cultural conditions. The purpose of this study was to analyze the anatomical MM distribution in the Chilean population in both strata searching for differences due to their ethno-genetic-cultural differences. Records of 1148 MM, 575 cases from state hospitals (Low Socioeconomic Strata, LSS) and 573 cases from private clinics (High Socioeconomic Strata, HSS) were analyzed by body site. Females from LSS showed a higher number of MM in soles, cheeks, and around the eye area. Females from the HSS showed a higher number of MM in dorsal feet and dorsal hands. Males from LSS showed a higher number of MM in soles, around the eye area, and cheeks. However, males from HSS showed a higher number of MM in the trunk, and in the arms. Acral MM was significantly higher in LSS than in the HSS in both sexes. The Chilean population from the HSS and LSS showed differences in the distribution of MM by site. Furthermore, gender differences in the proportion of MM analyzed by anatomical site are observed in both strata. Results show evidence that differential genetics factors, sun exposure, or other environmental or cultural factors of both strata may account for these differences.
Friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes
NASA Astrophysics Data System (ADS)
Deng, Jianxin; Yan, Pei; Wu, Ze
2012-11-01
MoS2 metal composite coatings have been successful used in dry turning, but its suitability for dry drilling has not been yet established. Therefore, it is necessary to study the friction and wear behaviors of MoS2/Zr coated HSS in sliding wear and in drilling processes. In the present study, MoS2/Zr composite coatings are deposited on the surface of W6Mo5Cr4V2 high speed steel(HSS). Microstructural and fundamental properties of these coatings are examined. Ball-on-disc sliding wear tests on the coated discs are carried out, and the drilling performance of the coated drills is tested. Test results show that the MoS2/Zr composite coatings exhibit decreases friction coefficient to that of the uncoated HSS in sliding wear tests. Energy dispersive X-ray(EDX) analysis on the wear surface indicates that there is a transfer layer formed on the counterpart ball during sliding wear processes, which contributes to the decreasing of the friction coefficient between the sliding couple. Drilling tests indicate that the MoS2/Zr coated drills show better cutting performance compared to the uncoated HSS drills, coating delamination and abrasive are found to be the main flank and rake wear mode of the coated drills. The proposed research founds the base of the application of MoS2 metal composite coatings on dry drilling.
Eskelinen, Matti; Ollonen, Paula
2011-01-01
In 1972, Beck introduced an inventory (BDI) for rapid screening of depression. The associations between the BDI and the risk of breast cancer (BC) are rarely considered together in prospective studies. In an extension of the Kuopio Breast Cancer Study, 115 women with breast cancer symptoms were semi-structurally interviewed in-depth as well as asked to complete standardised questionnaires (Forsen, Spielberger, MADRS), and all study variables were obtained before any diagnostic procedures were carried out. BDI was used to evaluate the depression of the study participants. The clinical examinations and biopsies showed BC in 34 patients, benign breast disease (BBD) in 53 patients, and 28 individuals were shown to be healthy (HSS). There was a trend for the women with HSS to have less sadness (BDI mean score, 0.27) than those of the BC (BDI mean score, 0.56) and BBD groups (BDI mean score, 0.49). The HSS group tended to be less pessimistic (BDI mean score, 0.15) than the patients in the BC group (BDI mean score, 0.44) and in the BBD group (BDI mean score, 0.42). The HSS group also had less self-accusation (BDI mean score, 0.19) than the patients in the BC group (BDI mean score, 0.50) and the patients in the BBD group (BDI mean score, 0.62). The HSS group also reported less work inhibition and weight loss than the patients in the BC group and in the BBD group. The mean sum of the scores of BDI variables was significantly lower in the HSS group (BDI mean score, 7.1) than in the BC (BDI mean score, 8.4) or BBD groups (BDI mean score, 8.8). The results of this study do not support a specific link between BDI and breast cancer risk. However, the patients with BC and BBD tended to have an increased risk for depressive symptoms.
Bährs, Hanno; Menzel, Ralph; Kubsch, Georg; Stösser, Reinhardt; Putschew, Anke; Heinze, Tobias; Steinberg, Christian E W
2012-06-01
Dissolved organic matter (DOM) has been shown to affect phytoplankton species directly. These interactions largely depend on the origin and molecular size of DOM and are different in prokaryotes and eukaryotes. In a preceding study, however, two humic substance preparations did not adversely affect coccal green algae or cyanobacterial growth even at high concentrations of dissolved organic carbon (DOC). These results contradicted previous findings, showing a clear, negative response of different phototrophs to much lower DOC concentrations. To test whether or not at least defined building blocks of humic substances (HSs) are effective algicidal structures, we enriched two humic preparations with hydroquinone and p-benzoquinone, respectively, and exposed two different green algae, Pseudokirchneriella subcapitata and Monoraphidium braunii, and two cyanobacterial species, Synechocystis sp. and Microcystis aeruginosa, to the unmodified and enriched HSs. As response variables, growth rates in terms of biomass increase, chlorophyll-a content, and photosynthetic yield were measured. The highest concentration (4.17 mM DOC) of the modified HSs clearly inhibited growth; the cyanobacterial species were much more sensitive than the green algal species. However, realistic ecological concentrations did not adversely affect growth. Aerating the exposure solution for 24 h strongly reduced the inhibitory effect of the modified HSs. The algicidal effect was obviously caused by monomers and not by polymerised high molecular weight HSs themselves. Furthermore, the maximum quantum yield (Φ PSII max) was stimulated in the green algal species by low and medium DOC concentrations, but reduced in the cyanobacterial species upon exposure to higher HS concentrations. The quinone- and phenol-enriched HSs only showed algicidal activity at high concentrations of 4.17 mM DOC and lost their effects over time, presumably by oxidation and subsequent polymerisation. This study confirms that the applied humic substances themselves are not effective algicides even if enriched in effective structures. Copyright © 2012 Elsevier Ltd. All rights reserved.
Eskelinen, Matti; Korhonen, Riika; Selander, Tuomas; Ollonen, Paula
2015-06-01
The relation between suicidal ideation versus hopelessness/helplessness in healthy study subjects (HSS) and in patients with benign breast disease (BBD) and breast cancer (BC) has not been compared to date in a prospective study. We, therefore, investigated suicidal ideation versus hopelessness/helplessness in 115 patients. In the Kuopio Breast Cancer Study, 115 women with breast symptoms were evaluated for hopelessness and helplessness versus suicidal/pessimistic thoughts before any diagnostic procedures were carried-out. In the self-rating score (SRS), hopelessness and the helplessness versus pessimistic thoughts were significantly correlated in the HSS, BBD and BC groups. In the SRS, the weighted kappa-values for hopelessness versus pessimistic thoughts in the BBD group were also statistically significant. There was also a significant positive correlation in the examiner-rating score (ERS) in the hopelessness versus pessimistic thoughts in the HSS, BBD and BC groups, as well as in the ERS, in the helplessness versus pessimistic thoughts in the HSS and BBD groups. In SRS, the hopelessness and the helplessness versus suicidal thoughts were significantly correlated in the HSS, BBD and BC groups. There was also a significant positive correlation in the ERS in the hopelessness versus suicidal thoughts in the HSS, BBD and BC groups, as well as in the ERS, in the helplessness versus suicidal thoughts in the BBD group. A new finding with clinical relevance in the present work is the agreement between hopelessness/helplessness versus suicidal/pessimistic thoughts in the self-rating and examiner-rating. In the breast cancer diagnostic Unit, the identification of suicidal ideation is essential in suicide prevention and it is important to assess and treat depression even though a subject reports little suicidal ideation. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Influence of coronal mass ejections on parameters of high-speed solar wind: a case study
NASA Astrophysics Data System (ADS)
Shugay, Yulia; Slemzin, Vladimir; Rodkin, Denis; Yermolaev, Yuri; Veselovsky, Igor
2018-05-01
We investigate the case of disagreement between predicted and observed in-situ parameters of the recurrent high-speed solar wind streams (HSSs) existing for Carrington rotation (CR) 2118 (December 2011) in comparison with CRs 2117 and 2119. The HSSs originated at the Sun from a recurrent polar coronal hole (CH) expanding to mid-latitudes, and its area in the central part of the solar disk increased with the rotation number. This part of the CH was responsible for the equatorial flank of the HSS directed to the Earth. The time and speed of arrival for this part of the HSS to the Earth were predicted by the hierarchical empirical model based on EUV-imaging and the Wang-Sheeley-Arge ENLIL semi-empirical replace model and compared with the parameters measured in-situ by model. The predicted parameters were compared with those measured in-situ. It was found, that for CR 2117 and CR 2119, the predicted HSS speed values agreed with the measured ones within the typical accuracy of ±100 km s-1. During CR 2118, the measured speed was on 217 km s-1 less than the value predicted in accordance with the increased area of the CH. We suppose that at CR 2118, the HSS overtook and interacted with complex ejecta formed from three merged coronal mass ejections (CMEs) with a mean speed about 400 km s-1. According to simulations of the Drag-based model, this complex ejecta might be created by several CMEs starting from the Sun in the period between 25 and 27 December 2011 and arriving to the Earth simultaneously with the HSS. Due to its higher density and magnetic field strength, the complex ejecta became an obstacle for the equatorial flank of the HSS and slowed it down. During CR 2117 and CR 2119, the CMEs appeared before the arrival of the HSSs, so the CMEs did not influence on the HSSs kinematics.
Development of a nanofiltration method for bone collagen 14C AMS dating
NASA Astrophysics Data System (ADS)
Boudin, Mathieu; Boeckx, Pascal; Buekenhoudt, Anita; Vandenabeele, Peter; Van Strydonck, Mark
2013-01-01
Radiocarbon dating of bones is usually performed on the collagen fraction. However, this collagen can contain exogenous molecules, including humic substances (HSs) and/or other soil components that may have a different age than the bone. Incomplete removal can result in biased 14C dates. Ultrafiltration of collagen, dissolved as gelatin (molecular weight (MW) ∼100,000 Dalton), has received considerable attention to obtain more reliable dates. Ultrafiltration is an effective method of removal of low-molecular weight contaminants from bone collagen but it does not remove high-molecular weight contaminants, such as cross-linked humic collagen complexes. However, comparative dating studies have raised the question whether this cleaning step itself may introduce contamination with carbon from the filters used. In this study, a nanofiltration method was developed using a ceramic filter to avoid a possible extraneous carbon contamination introduced by the filter. This method should be applicable to various protein materials e.g. collagen, silk, wool, leather and should be able to remove low-molecular and high molecular weight HSs. In this study bone collagen was hot acid hydrolyzed to amino acids and nanofiltrated. A filter with a molecular weight cutoff (MWCO) of 450 Dalton was chosen in order to collect the amino acids in the permeate and the HSs in the retentate. Two pilot studies were set up. Two nanofiltration types were tested in pilot study 1: dead end and cross flow filtration. Humic substance (HS)-solutions with fossil carbon and modern hydrolyzed collagen contaminated with HSs were filtrated and analyzed with spectrofluorescence to determine the HS removal. Cross flow nanofiltration showed the most efficient HS removal. A second pilot study based upon these results was set up wherein only cross flow filtration was performed. 14C measurements of the permeates of hydrolyzed modern collagen contaminated with fossil HSs demonstrate a significant but incomplete removal of HSs (between 63% and 85%).
Cservenka, Anita; Herting, Megan M.; Seghete, Kristen L. Mackiewicz; Hudson, Karen A.; Nagel, Bonnie J.
2012-01-01
Previous research has shown that personality characteristics, such as sensation seeking (SS), are strong predictors of risk-taking behavior during adolescence. However, the relationship between levels of SS and brain response has not been studied during this time period. Given the prevalence of risky behavior during adolescence, it is important to understand neurobiological differences in reward sensitivity between youth with high and low SS personalities. To this end, we used functional magnetic resonance imaging (fMRI) to examine differences in brain activity in an adolescent sample that included 27 high (HSS) and 27 low sensation seekers (LSS), defined by the Impulsive Sensation Seeking scale of the Zuckerman-Kuhlman Personality Questionnaire (Zuckerman et al., 1993). In the scanner, participants played a modified Wheel of Fortune decision-making task (Cservenka and Nagel, 2012) that resulted in trials with monetary Wins or No Wins. We compared age- and sex-matched adolescent HSS and LSS (mean age = 13.94 ± 1.05) on brain activity by contrasting Win versus No Win trials. Our findings indicate that HSS show greater bilateral insular and prefrontal cortex (PFC) brain response on Win vs. No Win compared to LSS. Analysis of simple effects showed that while LSS showed comparable brain activity in these areas during Wins and No Wins, HSS showed significant differences in brain response to winning (activation) versus not winning (deactivation), with between-group comparison suggesting significant differences in brain response, largely to reward absence. Group differences in insular activation between reward receipt and absence may suggest weak autonomic arousal to negative outcomes in HSS compared with LSS. Additionally, since the PFC is important for goal-directed behavior and attention, the current results may reflect that HSS allocate fewer attentional resources to negative outcomes than LSS. This insensitivity to reward absence in HSS may lead to a greater likelihood of maladaptive choices when negative consequences are not considered, and may be an early neural marker of decreased loss sensitivity that has been seen in addiction. This neurobiological information may ultimately be helpful in establishing prevention strategies aimed at reducing youth risk-taking and suggests value in further examination of neural associations with personality characteristics during adolescence. PMID:23142276
Gentry, S V; Powers, E F J; Azim, N; Maidrag, M
2018-07-01
Voluntary befriending schemes operate in many countries, promoting public health by supporting vulnerable individuals and families. Use of third sector and voluntary services to complement health and social care provision is increasingly important globally in the context of economic and demographic challenges, but the evidence base around such collaborations is limited. This article reports the results of operational evaluation research seeking to use robust routine work to generate transferable findings for use by those commissioning and providing services. The subject of our evaluation research is 'Home-Start Suffolk' (HSS) in Suffolk County, UK, an example of a third sector organisation commissioned to support the public health offer to local families. This evaluation research used the Donabedian framework, which assesses the structure, process and outcome in delivery of health services. Methods included a cross-sectional stakeholder survey with qualitative and quantitative elements (n = 96), qualitative interviews (n = 41) and quantitative analysis of the service's routine data (5740 visits) for the period from 01 July 2014 to 01 July 2016. Triangulation of data from each component revealed that HSS was perceived by diverse stakeholders to successfully support families in need of additional help. HSS service users perceived the service to offer greater flexibility, to be tailored to their needs and to be more trustworthy and supportive than statutory services. Volunteering with HSS enabled people to feel productive in their community and gain new skills. Managers of social care services perceived that HSS activity decreased burden on their staff. These benefits were facilitated through a long-standing organisational HSS structure and relationships between HSS and social care. Challenges posed by service provision by a third sector organisation included the need for volunteers to negotiate the boundary between being a friend and a professional outside of a professional framework. Quantitative analysis of impact was limited by the poor quality of routinely collected administrative data, highlighting the importance of planning processes for data collection with evaluation in mind. We believe that the results of this evaluation research provide transferrable lessons. They demonstrate how a third sector organisation with a long-standing structure and relationships with statutory services was able to reduce perceived service burden while also offering support in a more flexible and tailored way greatly valued by service users. Copyright © 2018 The Royal Society for Public Health. All rights reserved.
Adolescents' Interest in and Views of Destructive Themes in Rock Music.
ERIC Educational Resources Information Center
Wass, Hannelore; And Others
1989-01-01
Surveyed 694 adolescents concerning rock music preferences and views on homicide, satanism, and suicide (HSS) themes. Nine percent of middle school students, 17 percent of rural and 24percent of urban high school students were HSS rock fans. Three-fourths of fans were male, majority were White. Many students expressed concerns about destructive…
Cadmium Alternatives High Strength Steel JTP
2005-03-01
Cadmium Alternatives HSS JTP Alternative Coatings Selected by JCAT: Primary Repair LHE Cadmium (control) IVD Aluminum (control) Zinc-Nickel, acid...Tin-Zinc Cadmium Alternatives HSS JTP Demonstration Tests Selected by JCAT: Phase I Phase II Hydrogen Embrittlement Hydrogen Re-Embrittlement (NRB...immersion, exposed C-ring (Army)) Bend Adhesion (Q/A) Appearance Throwing Power Composition Uniformity Strippability Galvanic Potential Bend Adhesion
Particle accelerators in the hot spots of radio galaxy 3C 445, imaged with the VLT.
Prieto, M Almudena; Brunetti, Gianfranco; Mack, Karl-Heinz
2002-10-04
Hot spots (HSs) are regions of enhanced radio emission produced by supersonic jets at the tip of the radio lobes of powerful radio sources. Obtained with the Very Large Telescope (VLT), images of the HSs in the radio galaxy 3C 445 show bright knots embedded in diffuse optical emission distributed along the post-shock region created by the impact of the jet into the intergalactic medium. The observations reported here confirm that relativistic electrons are accelerated by Fermi-I acceleration processes in HSs. Furthermore, both the diffuse emission tracing the rims of the front shock and the multiple knots demonstrate the presence of additional continuous re-acceleration processes of electrons (Fermi-II).
Min, Jun Zhe; Shimizu, Yoshiha; Toyo'oka, Toshimasa; Inagaki, Shinsuke; Kikura-Hanajiri, Ruri; Goda, Yukihiro
2008-10-01
To avoid the spreading of illegal drugs, a designated drug regulation system was introduced along with revision of the Pharmaceutical Affairs Law in Japan in 2006, and 32 substances including phenethylamine-type drugs were listed in April 2007. In this study, a new simultaneous determination method, based on ultra-fast liquid chromatography coupled with fluorescence detection (UFLC-FL), was developed for the 11 designated phenethylamine drugs. The phenethylamines were labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 degrees C for 2h in 0.1M borax (pH 9.3). The resulting 11 fluorophores were completely separated by reversed-phase chromatography using an ACQUITY UPLC BEH C(18) column (2.1 mm x 100 mm 1.7 microm) and fluorometrically detected at 550 nm (excitation at 450 nm). The calibration curves obtained from the peak areas versus the injection amounts of the phenethylamines showed a good linearity. The limits of detection (signal-to-noise ratio of 3: S/N=3) on the chromatogram were in the range from 10 fmol (PMMA) to 2.5pmol (MMDA-2). Good accuracy (%) and precision (CV) by intra-day assay and inter-day assay were also obtained using the present procedure. The method was applied to the qualitative and quantitative analyses of phenethylamine in real products obtained from the Japanese market. As the results, BDB (0.24 mg/mg), MMDA-2 (0.98 mg/mL) and 2C-I (0.016 mg/mg) were identified from the different products (powder, liquid and mushroom like). Because the procedure is simple, selective and sensitive, the present method seems to be useful for the qualitative and quantitative analyses of the designated phenethylamines in various samples including biological specimens.
Hou, Xiao-Lin; Chen, Guo; Zhu, Li; Yang, Ting; Zhao, Jian; Wang, Lei; Wu, Yin-Liang
2014-07-01
A simple, sensitive and reliable analytical method was developed for the simultaneous determination of 38 veterinary drugs (18 sulfonamides, 11 quinolones and 9 benzimidazoles) and 8 metabolites of benzimidazoles in bovine milk by ultra high performance liquid chromatography-positive electrospray ionization tandem mass spectrometry (UHPLC-ESI-MS/MS). Samples were extracted with acidified acetonitrile, cleaned up with Oasis(®) MCX cartridges, and analyzed by LC-MS/MS on an Acquity UPLC(®) BEH C18 column with gradient elution. The method allows such multi-analyte measurements within a 13min runtime while the specificity is ensured through the MRM acquisition mode. The method was validated according to the European Commission Decision 2002/657/EC determining specificity, decision limit (CCα), detection capability (CCβ), recovery, precision, linearity and stability. For compounds which have MRLs in bovine milk, the CCα values fall into a range from 11 to 115μg/kg, and the CCβ values fall within a range of 12-125μg/kg. For compounds which have not MRLs in bovine milk, the CCα values fall into a range from 0.01 to 0.08μg/kg, and the CCβ values fall within a range of 0.02-0.11μg/kg. The mean recoveries of the 46 analytes were between 87 and 119%. The calculated RSD values of repeatability and within-laboratory reproducibility experiments were below 11% and 15% for the 46 compounds, respectively. The method was demonstrated to be suitable for the simultaneous determination of sulfonamides, quinolones and benzimidazoles in bovine milk. Copyright © 2014 Elsevier B.V. All rights reserved.
Chen, Xiaopeng; Walter, Kyla M; Miller, Galen W; Lein, Pamela J; Puschner, Birgit
2018-06-01
Environmental toxicants that interfere with thyroid hormone (TH) signaling can impact growth and development in animals and humans. Zebrafish represent a model to study chemically induced TH disruption, prompting the need for sensitive detection of THs. Simultaneous quantification of 3,3',5-triiodo-l-thyronine (T3), thyroxine (T4), 3,3',5'-triiodo-l-thyronine (rT3), 3,5-diiodo-l-thyronine (3,5-T2) and 3,3'-diiodo-l-thyronine (3,3'-T2) in zebrafish larvae was achieved by ultra-performance liquid chromatography-tandem mass spectrometry in positive ion mode. Solid-phase extraction with SampliQ cartridges and derivatization with 3 m hydrochloric acid in n-butanol reduced matrix effects. Derivatized compounds were separated on an Acquity UPLC BEH C 18 column with mobile phases consisting of 0.1% acetic acid in deionized water and 0.1% acetic acid in methanol. The limits of detection ranged from 0.5 to 0.6 pg injected on column. The method was validated by evaluating recovery (77.1-117.2%), accuracy (87.3-123.9%) and precision (0.5-12.4%) using diluted homogenized zebrafish embryos spiked with all target compounds. This method was then applied to zebrafish larvae collected after 114 h of exposure to polychlorinated biphenyls (PCBs), including PCB 28, PCB 66 and PCB 95, or the technical mixture Aroclor 1254. Exposure to PCB 28 and PCB 95 increased the T4:T3 ratio and decreased the T3:rT3 ratio, demonstrating that this method can effectively detect PCB-induced alterations in THs. Copyright © 2018 John Wiley & Sons, Ltd.
Jamalapuram, Seshulatha; Vuppala, Pradeep K.; Mesangeau, Christophe; McCurdy, Christopher R.; Avery, Bonnie A.
2014-01-01
A selective, rapid and sensitive ultra performance liquid chromatography mass spectrometry (UPLC/MS) method was developed and validated to quantitate a highly selective mixed-affinity sigma receptor ligand, CM156 (3-(4-(4-cyclohexylpiperazin-1-yl)butyl)benzo[d] thiazole-2(3H)-thione), in rat plasma. CM156 and the internal standard (aripiprazole) were extracted from plasma samples by a single step liquid–liquid extraction using chloroform. The analysis was carried out on an ACQUITY UPLCTM BEH HILIC column (1.7 µm, 2.1 mm × 50 mm) with isocratic elution at flow rate of 0.2 mL/min using 10 mM ammonium formate in 0.1% formic acid and acetonitrile (10:90) as the mobile phase. The detection of the analyte was performed on a mass spectrometer operated in selected ion recording (SIR) mode with positive electrospray ionization (ESI). The validated analytical method resulted in a run time of 4 min and the retention times observed were 2.6 ± 0.1 and 2.1 ± 0.1 min for CM156 and the IS, respectively. The calibration curve exhibited excellent linearity over a concentration range of 5–4000 ng/mL with the lower limit of quantification of 5 ng/mL. The intra- and inter-day precision values were below 15% and accuracy ranged from −6.5% to 5.0%. The mean recovery of CM156 from plasma was 96.8%. The validated method was applied to a pilot intravenous pharmacokinetic study in rats. PMID:22406103
Zheng, Zhijie; Yan, Tongmeng; Chen, Weiying; Ye, Ling; Tang, Lan; Liu, Zhongqiu
2012-08-01
A rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry method was developed and validated for the determination and quantification of ephedrine in rat plasma samples. An Acquity UPLC BEH C18 column (1.7 μm, 2.1 mm × 50 mm) was used for chromatographic separation. Electrospray ionization in the positive mode was used, and the precursor-fragment ion pairs of m/z 166/148 and m/z 289/97 were adopted to characterize ephedrine and testosterone (internal standard), respectively. The method was validated using 10, 100 and 500 ng/mL of ephedrine. It demonstrated adequate levels of precision and accuracy, matrix effect, extraction recovery and stability. Linearity over the concentration range of 0.5-2000 ng/mL was acceptable with a correlation coefficient (r²) better than 0.990. To determine the pharmacokinetic behaviour of this sympathomimetic compound in the Sprague-Dawley rats, ephedrine hydrochloride, Herba Ephedrae single-herb and Wu Tou Tang decoctions were administered orally, and ephedrine hydrochloride was also administered by intravenous injection, and blood samples were collected over 24 h. Ephedrine was measured in plasma and pharmacokinetic parameters were determined by using the standard non-compartmental method and calculated by using Practical Pharmacokinetic Program-Version 87/97. The AUC(0-t) and T(max) values were significantly different (p < 0.05). Ephedrine AUC(0-t) values were significantly lower following the Wu Tou Tang decoction compared to the other oral treatments, suggesting that some components in the decoction may reduce the bioavailability of ephedrine.
Kumar, Navneet; Sangeetha, Dhanaraj; Reddy, Sunil P
2012-10-01
The objective of the current investigation was to study the degradation behavior of irinotecan hydrochloride under different International Conference on Harmonization (ICH) recommended stress conditions using ultra-performance liquid chromatography and liquid chromatography-mass spectrometry and to establish a validated stability-indicating reverse-phase ultra-performance liquid chromatographic method for the quantitative determination of irinotecan hydrochloride and its seven impurities and degradation products in pharmaceutical dosage forms. Irinotecan hydrochloride was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal and photolytic degradation. Irinotecan hydrochloride was found to degrade significantly in oxidative and base hydrolysis and photolytic degradation conditions. The degradation products were well resolved from the main peak and its impurities, thus proving the stability-indicating power of the method. Chromatographic separation was achieved on a Waters Acquity BEH C8 (100 × 2.1 mm) 1.7-µm column with a mobile phase containing a gradient mixture of solvent A (0.02M KH(2)PO(4) buffer, pH 3.4) and solvent B (a mixture of acetonitrile and methanol in the ratio of 62:38 v/v). The mobile phase was delivered at a flow rate of 0.3 mL/min with ultraviolet detection at 220 nm. The run time was 8 min, within which irinotecan and its seven impurities and degradation products were satisfactorily separated. The developed method was validated as per ICH guidelines with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness. This method was also suitable for the assay determination of irinotecan hydrochloride in pharmaceutical dosage forms.
Lien, Guang-Wen; Wen, Ting-Wen; Hsieh, Wu-Shiun; Wu, Kuen-Yuh; Chen, Chia-Yang; Chen, Pau-Chung
2011-03-15
Perfluorinated compounds (PFCs) can cross the placental barrier and enter fetal circulation. This study aimed at developing a fast and sensitive ultra-high performance liquid chromatography/tandem mass spectrometry method for the determination of twelve perfluorinated compounds in cord blood. Samples were processed with protein precipitation using formic acid and methanol, mixed with stable isotope labeled standard, followed by sonication and centrifugation, and were analyzed using a Waters ACQUITY UPLC coupled with a Waters Quattro Premier XE triple-quadrupole mass spectrometer. The instrument was operated in selected reaction monitoring (SRM) with negative electrospray ionization. Using BEH C(18) column (2.1 mm×50 mm, 1.7 μm) with 10-mM N-methylmorpholine/methanol gradient elution provided a fast chromatographic separation (5.5 min) and sharp peaks. Intra- and inter-day calibration bias was less than 7% and intra- and inter-day calibration of relative standard deviations were within 0.02-8.22% for all the analytes and concentrations. The recoveries of PFCs spiked into bovine serum ranged from 85 to 104% with relative standard deviations from 0.02 to 6.37%. The limits of quantitation (LOQs), defined as a signal-to-noise ratio of ten, ranged from 0.15 to 3.1 ng/mL for the twelve PFCs. Perfluorooctanoic acid (PFOA), perfluorooctyl sulfonate (PFOS), perfluoroundecanoic acid (PFUA) and perfluorononanoic acid (PFNA) were detected in up to 68% of umbilical cord plasma (n=444) in Taiwan Birth Panel Study and the health effect of these chemicals on children developmental deserves further investigation. Copyright © 2011 Elsevier B.V. All rights reserved.
Luque-Muñoz, A; Vílchez, J L; Zafra-Gómez, A
2017-07-21
An analytical method for the analysis of 16 pharmaceuticals and personal care products in compost from sewage sludge is successfully validated. Ultrasound assisted extraction with a mixture of acetonitrile:ethyl acetate (1:1, v/v) containing 10% (v/v) of acetic acid was carried out. Two cycles of extraction of 10min were applied. A clean-up of the extracts using salt-assisted liquid-liquid extraction (SALLE) was also included. Experimental design was used for the optimization of the main parameters involved in the extraction and cleaned-up steps. The chromatographic separation was carried out by ultrahigh performance liquid chromatography using a mobile phase gradient mixture of a 13mM buffer ammonium formate solution (pH 9.25) (solvent A) and methanol (solvent B). An ACQUITY UPLC ® BEH C18 column (1.7μm; 2.1×50mm) column was used. Analytes were separated in less than 11min. The compounds were detected and quantified using single reaction monitoring electrospray tandem mass spectrometry. The limits of detection calculated ranged from 0.5 to 4ngg -1 d.w., and the limits of quantification from 2 to 13ngg -1 d.w. Recoveries from 93% to 111%, with relative standar deviations lower than 11% in all cases, were obtained. The method was applied to natural compost samples. High concentrations of some analytes were found. Ketoprofen (510ngg -1 d.w.), methylparaben (240ngg -1 d.w.), diclofenac (175ngg -1 d.w.) and flufenamic acid (128ngg -1 d.w.) were the most abundant. Copyright © 2017 Elsevier B.V. All rights reserved.
Dong, Hao; Zeng, Xiaofang; Bai, Weidong
2018-08-30
The present study reports an ultra high-performance liquid chromatography tandem mass spectrometry method for the simultaneous determination of six bisphenols (bisphenol A, bisphenol B and bisphenol F) and alkylphenols (4-nonylphenol, 4-n-nonylphenol and octylphenol) in hotpot seasoning. Samples were dispersed in n-hexane after addition of internal standards bisphenol A-d 4 and 4-n-nonylphenol-d 4 . Sample solutions were then centrifuged, and the supernatants purified using solid phase extraction with high polarity Carb/PSA composite fillers. Six target analytes were separated on a Waters ACQUITY BEH C18 column by gradient elution with methanol and 0.05% ammonium hydroxide in water as the mobile phase, and determined under multiple reactions monitoring mode. The limits of detection and quantitation, matrix effect, recovery and precision of the method were investigated. Results were linear in the concentration range 0.1-250 µg/L for all compounds of interest, with R 2 > 0.9950. Limits of detection were in the range 0.1-0.4 μg/kg, and limits of quantitation were between 0.5 μg/kg and 1.0 μg/kg. The mean recoveries for negative samples at three spiked concentrations were in the range 87.9%-102.4%, and the intra-day precision and inter-day precision were in the ranges 2.1-8.2% and 4.8-11.2%, respectively. This method is accurate and sensitive, and had good clean-up characteristics, which might apply to screening and quantitation of target bisphenols and alkylphenols in hotpot seasoning. Copyright © 2018 Elsevier Ltd. All rights reserved.
Swain, Debasish; Patel, Prinesh N; Palaniappan, Ilayaraja; Sahu, Gayatri; Samanthula, Gananadhamu
2015-08-15
Azilsartan medoxomil potassium (AZM) is a new antihypertensive drug introduced in the year 2011. The presence of degradation products not only affects the quality, but also the safety aspects of the drug. Thus, it is essential to develop an efficient analytical method which could be useful to selectively separate and identify the degradation products of azilsartan medoxomil potassium. AZM was subjected to forced degradation under hydrolytic (acid, base and neutral), oxidative, photolytic and thermal stress conditions. Separation of the drug and degradation products was achieved by a liquid chromatography (LC) method using an Acquity UPLC(®) C18 CSH column with mobile phase consisting of 0.02% trifluoroacetic acid and acetonitrile using a gradient method. Identification and characterization of the degradation products was carried out using LC/electrospray ionization quadrupole time-of-flight mass spectrometry (ESI-QTOFMS). A total of five degradation products (DP 1 to DP 5) were formed under various stress conditions and their structures were proposed with the help of tandem mass spectrometry (MS/MS) experiments and accurate mass data. A common degradation product (DP 4) was observed under all the degradation conditions. DP 1, DP 2 and DP 5 were observed under acid hydrolytic conditions whereas DP 3 was observed under alkaline conditions. AZM was found to degrade under hydrolytic, oxidative and photolytic stress conditions. The structures of all the degradation products were proposed. The degradation pathway for the formation of degradation products was also hypothesized. A selective method was developed to quantify the drug in the presence of degradation products which is useful to monitor the quality of AZM. Copyright © 2015 John Wiley & Sons, Ltd.
Leng, Ping; Yang, Zhao; Ma, Baohua; Li, Jing; Sun, Jialin; Xie, Yiming; Sun, Yong
2018-03-05
A compound (WJD-A-1) was previously reported as a candidate prodrug of Am80 (tamibarotene), which was approved in Japan in 2005 as a therapeutic agent for recurrent refractory acute promyelocytic leukaemia. A rapid, selective and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed for the first time to simultaneously determine WJD-A-1 and its major phase-I metabolites AM80 in rat plasma. After a simple sample preparation procedure by protein precipitation with methanol and acetonitrile, WJD-A-1, AM80 and the internal standard were chromatographed on an ACQUITY UPLC TM BEH C 18 column. The mobile phase consisted of methanol-0.1% formic acid (80:20, v/v) and the flow rate was 0.20 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI) source. Each plasma sample was chromatographed within 2.6 min. The linear calibration curves for WJD-A-1 and the AM80 were obtained in the concentration range of 5.40-5.40 × 10 3 and 5.08-5.08 × 10 3 ng/mL, respectively (r ≥ 0.99). The intra- and inter-day precision (relative standard deviation, RSD) values were less than 8% and the accuracy (relative error, RE) was within ±6.8%, determined from quality control (QC) samples for the analytes. The method herein described was fully validated and successfully applied to pharmacokinetic study of WJD-A-1 following an intravenous administration of 300 μg/kg WJD-A-1 to rats.
Karinen, Ritva; Vindenes, Vigdis; Hasvold, Inger; Olsen, Kirsten Midtbøen; Christophersen, Asbjørg S; Øiestad, Elisabeth
2015-07-01
Quantitative determination of anti-epileptic drug concentrations is of great importance in forensic toxicology cases. Although the drugs are not usually abused, they are important post-mortem cases where the question of both lack of compliance and accidental or deliberate poisoning might be raised. In addition these drugs can be relevant for driving under the influence cases. A reversed phase ultra-performance liquid chromatography-tandem mass spectrometry method has been developed for the quantitative analysis of the anti-epileptic compounds carbamazepine, carbamazepine-10,11-epoxide, gabapentin, lamotrigine, levetiracetam, oxcarbazepine, 10-OH-carbazepine, phenobarbital, phenytoin, pregabalin, and topiramate in whole blood, using 0.1 mL sample volume with methaqualone as internal standard. Sample preparation was a simple protein precipitation with acetonitrile and methanol. The diluted supernatant was directly injected into the chromatographic system. Separation was performed on an Acquity UPLC® BEH Phenyl column with gradient elution and a mildly alkaline mobile phase. The mass spectrometric detection was performed in positive ion mode, except for phenobarbital, and multiple reaction monitoring was used for drug quantification. The limits of quantification for the different anti-epileptic drugs varied from 0.064 to 1.26 mg/L in blood, within-day and day-to-day relative standard deviations from 2.2 to 14.7% except for phenobarbital. Between-day variation for phenobarbital was 20.4% at the concentration level of 3.5 mg/L. The biases for all compounds were within ±17.5%. The recoveries ranged between 85 and 120%. The corrected matrix effects were 88-106% and 84-110% in ante-mortem and post-mortem whole blood samples, respectively. Copyright © 2014 John Wiley & Sons, Ltd.
Zhang, Yan; Liu, Peng; Li, Ning; Wu, Di; Feng, Yun; Song, Yuanyuan; Shi, Yuankai; Han, Xiaohong
2016-07-01
To support a novel anthracycline agent - Sabarubicin's pharmacokinetics study in Chinese small cell lung cancer patients, a rapid, sensitive, and high throughput ultra-performance liquid chromatography tandem mass spectrometry method using Doxorubicin hydrochloride as internal standard (IS) was developed and validated for simultaneously quantifying Sabarubicin and its alcohol metabolite M3 in human plasma. Plasma samples were pre-extracted with n-hexane to remove hydrophobic interferences and the target compounds were extracted into a 1ml mixture of chloroform and isopropanol (1:1, v/v) and separated on an ACQUITY UPLC BEH Shield RP18 (100mm×2.1mm, 1.7μm) column with gradient mobile phase composed of acetonitrile and water containing 0.1% formic acid. Detection was performed by electrospray ionization in the positive ionization mode under multiple reaction monitoring of the transitions at m/z 644→130 for Sabarubicin, m/z 646→333.2 for M3, and m/z 544→360 for IS. For Sabarubicin and M3, calibration curves over 2-400ng/ml and 0.5-100ng/ml could achieve excellent linearity respectively(r>0.99). Intra- and inter-day precisions were 1.5%-9.1% and 2.2%-12.8%, and accuracy were -9.6% to 0.7% and -4.8% to 5.9% for Sabarubicin and M3 respectively at four concentration levels. The mean recovery for Sabarubicin was 62.4%, 71.9% for M3, and 58.8% for IS. This method was completely validated and successfully applied in the pharmacokinetics study of Sabarubicin and M3 in Chinese small cell lung cancer patients. Copyright © 2016 Elsevier B.V. All rights reserved.
Ansermot, Nicolas; Brawand-Amey, Marlyse; Kottelat, Astrid; Eap, Chin B
2013-05-31
A sensitive and selective ultra-high performance liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was developed for the fast quantification of ten psychotropic drugs and metabolites in human plasma for the needs of our laboratory (amisulpride, asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, norquetiapine, olanzapine, paliperidone, quetiapine and risperidone). Stable isotope-labeled internal standards were used for all analytes, to compensate for the global method variability, including extraction and ionization variations. Sample preparation was performed by generic protein precipitation with acetonitrile. Chromatographic separation was achieved in less than 3.0min on an Acquity UPLC BEH Shield RP18 column (2.1mm×50mm; 1.7μm), using a gradient elution of 10mM ammonium formate buffer pH 3.0 and acetonitrile at a flow rate of 0.4ml/min. The compounds were quantified on a tandem quadrupole mass spectrometer operating in positive electrospray ionization mode, using multiple reaction monitoring. The method was fully validated according to the latest recommendations of international guidelines. Eight point calibration curves were used to cover a large concentration range 0.5-200ng/ml for asenapine, desmethyl-mirtazapine, iloperidone, mirtazapine, olanzapine, paliperidone and risperidone, and 1-1500ng/ml for amisulpride, norquetiapine and quetiapine. Good quantitative performances were achieved in terms of trueness (93.1-111.2%), repeatability (1.3-8.6%) and intermediate precision (1.8-11.5%). Internal standard-normalized matrix effects ranged between 95 and 105%, with a variability never exceeding 6%. The accuracy profiles (total error) were included in the acceptance limits of ±30% for biological samples. This method is therefore suitable for both therapeutic drug monitoring and pharmacokinetic studies. Copyright © 2013 Elsevier B.V. All rights reserved.
Kim, Ji-Sun; An, Chul Geon; Park, Jong-Suk; Lim, Yong Pyo; Kim, Suna
2016-06-15
In this study, we investigated carotenoid profiles and contents from 27 types of paprika with different colors (red, orange, and yellow), shapes (blocky and conical), and cultivation methods (soil and soilless). We simultaneously analyzed 12 kinds of carotenoids using UPLC equipped with an HSS T3 column for 30 min, and we identified six kinds of carotenoids in red paprika and nine types in orange and yellow paprika. Zeaxanthin concentrations in orange paprika were in the range of 85.06±23.37-151.39±5.94 mg/100 g dry weight (dw), which shows that orange paprika is a great source of zeaxanthin. Generally, red paprika is a great source of capsanthin. However, a new cultivar, 'Mini Goggal Red', contained large amounts of zeaxanthin (121.41±30.10 mg/100 g dw) even though its visible color is red. This is very meaningful considering that consumers have a preference for red color and the potent functional value of zeaxanthin. Carotenoid profiles and concentrations in blocky and conical type paprika were not significantly different in red paprika except the 'Mini Goggal Red' cultivar and yellow paprika. Blocky type orange paprika contains plenty of zeaxanthin, unlike conical type orange paprika. Three new cultivars of the conical type were cultivated in both soil culture and soilless culture in the same province, and carotenoid profiles and concentrations were similar, showing that both cultivations methods can be used. Copyright © 2016. Published by Elsevier Ltd.
Sun, Wanyang; Tong, Ling; Miao, Jingzhuo; Huang, Jingyi; Li, Dongxiang; Li, Yunfei; Xiao, Hongting; Sun, Henry; Bi, Kaishun
2016-01-29
Salvia miltiorrhiza (SM) is one of the most widely used Traditional Chinese Medicine. Active constituents of SM mainly contain hydrophilic phenolic acids (PAs) and lipophilic tanshinones. However, due to the existing of multiple ester bonds and unsaturated bonds in the structures, PAs have numerous chemical conversion products. Many of them are so low-abundant that hard to be separated using conventional methods. In this study, an off-line two-dimensional liquid chromatography (2D-LC) method was developed to separate PAs in SM and its related preparations. In the first dimension, samples were fractionated by hydrophilic interaction chromatography (HILIC) (Acchrom×Amide, 4.6×250mm, 5μm) mainly based on the hydrogen bonding effects. The fractions were then separated on reversed-phase liquid chromatography (RP-LC) (Acquity HSS T3, 2.1×50mm, 1.7μm) according to hydrophobicity. For the selective identification of PAs, diode array detector (DAD) and electrospray ionization tandem ion trap time-of-flight mass spectrometry (ESI-IT-TOF-MS) were employed. Practical and effective peak capacities of all the samples were greater than 2046 and 1130, respectively, with the orthogonalities ranged from 69.7% to 92.8%, which indicated the high efficiency and versatility of this method. By utilizing the data post-processing techniques, including mass defect filter, neutral loss filter and product ion filter, a total of 265 compounds comprising 196 potentially new PAs were tentatively characterized. Twelve kinds of derivatives, mainly including glycosylated compounds, O-alkylated compounds, condensed compounds and hydrolyzed compounds, constituted the novelty of the newly identified PAs. The HILIC×RP-LC/TOF-MS system expanded our understanding on PAs of S. miltiorrhiza and its related preparations, which could also benefit the separation and characterization of polar constituents in complicated herbal extracts. Copyright © 2016. Published by Elsevier B.V.
Guardia-Olmos, Joan; Zarabozo-Hurtado, Daniel; Peró-Cebollero, Maribe; Gudayol-Farré, Esteban; Gómez-Velázquez, Fabiola R; González-Garrido, Andrés
2017-12-04
The study of orthographic errors in a transparent language such as Spanish is an important topic in relation to writing acquisition because in Spanish it is common to write pseudohomophones as valid words. The main objective of the present study was to explore the possible differences in activation patterns in brain areas while processing pseudohomophone orthographic errors between participants with high (High Spelling Skills (HSS)) and low (Low Spelling Skills (LSS)) spelling orthographic abilities. We hypothesize that (a) the detection of orthographic errors will activate bilateral inferior frontal gyri, and that (b) this effect will be greater in the HSS group. Two groups of 12 Mexican participants, each matched by age, were formed based on their results in a group of spelling-related ad hoc tests: HSS and LSS groups. During the fMRI session, two experimental tasks were applied involving correct and pseudohomophone substitution of Spanish words. First, a spelling recognition task and second a letter searching task. The LSS group showed, as expected, a lower number of correct responses (F(1, 21) = 52.72, p <.001, η2 = .715) and higher reaction times compared to the HSS group for the spelling task (F(1, 21) = 60.03, p <.001, η2 = .741). However, this pattern was reversed when the participants were asked to decide on the presence of a vowel in the words, regardless of spelling. The fMRI data showed an engagement of the right inferior frontal gyrus in HSS group during the spelling task. However, temporal, frontal, and subcortical brain regions of the LSS group were activated during the same task.
Performance test of different 3.5 mm drill bits and consequences for orthopaedic surgery.
Clement, Hans; Zopf, Christoph; Brandner, Markus; Tesch, Norbert P; Vallant, Rudolf; Puchwein, Paul
2015-12-01
Drilling of bones in orthopaedic and trauma surgery is a common procedure. There are yet no recommendations about which drill bits/coating should be preferred and when to change a used drill bit. In preliminary studies typical "drilling patterns" of surgeons concerning used spindle speed and feeding force were recorded. Different feeding forces were tested and abrasion was analysed using magnification and a scanning electron microscope (SEM). Acquired data were used for programming a friction stir welding machine (FSWM). Four drill bits (a default AISI 440A, a HSS, an AISI 440B and a Zirconium-oxide drill bit) were analysed for abrasive wear after 20/40/60 machine-guided and hand-driven drilled holes. Additionally different drill coatings [diamond-like carbon/grafitic (DLC), titanium nitride/carbide (Ti-N)] were tested. The mean applied feeding force by surgeons was 45 ± 15.6 Newton (N). HSS bits were still usable after 51 drill holes. Both coated AISI 440A bits showed considerable breakouts of the main cutting edge after 20 hand-driven drilled holes. The coated HSS bit showed very low abrasive wear. The non-coated AISI 440B bit had a similar durability to the HSS bits. The ZrO2 dental drill bit excelled its competitors (no considerable abrasive wear at >100 holes). If the default AISI 440A drill bit cannot be checked by 20-30× magnification after surgery, it should be replaced after 20 hand-driven drilled holes. Low price coated HSS bits could be a powerful alternative.
ERIC Educational Resources Information Center
Li, Yongyan; Flowerdew, John
2009-01-01
It has been recognized that English as the language of international scholarship represents a more complex picture in the humanities and social sciences (HSS) than in science and engineering, with multilingual scholars in the HSS often negotiating international engagement and local commitment by publishing both in English and their first language.…
ERIC Educational Resources Information Center
Jensen, Jakob; Imboden, Kristen; Ivic, Rebecca
2011-01-01
High sensation seekers (HSS) prefer messages that allow them to maintain an optimal level of arousal (i.e., highly arousing messages). Transportation theory suggests that narrative immersion in a story may moderate reader arousal, and thus HSS message selection. To test this idea, a survey was administered to 120 fourth and fifth graders. In…
ERIC Educational Resources Information Center
Stering, Edward
This document shares a vision for a 4-year curriculum for Heritage Speakers of Spanish (HSS)/Spanish for Native Speakers (SNS), describing a course developed for SNS students within Mercy High School in San Francisco, California. The vision foresees an ever-increasing number of HSS and SNS students completing college level degree programs then…
Investigation of DC hybrid circuit breaker based on high-speed switch and arc generator
NASA Astrophysics Data System (ADS)
Wu, Yifei; Rong, Mingzhe; Wu, Yi; Yang, Fei; Li, Mei; Zhong, Jianying; Han, Guohui; Niu, Chunping; Hu, Yang
2015-02-01
A new design of DC hybrid circuit breaker based on high-speed switch (HSS) and arc generator (AG), which can drastically profit from low heat loss in normal state and fast current breaking under fault state, is presented and analyzed in this paper. AG is designed according to the magnetic pinch effect of liquid metal. By utilizing the arc voltage generated across AG, the fault current is rapidly commutated from HSS into parallel connected branch. As a consequence, the arcless open of HSS is achieved. The post-arc conducting resume time (Δ tc) of AG and the commutation original voltage (Uc), two key factors in the commutation process, are investigated experimentally. Particularly, influences of the liquid metal channel diameter (Φ) of AG, fault current rate of rise (di/dt) and Uc on Δ tc are focused on. Furthermore, a suitable Uc is determined during the current commutation process, aiming at the reliable arcless open of HSS and short breaking time. Finally, the fault current breaking test is carried out for the current peak value of 11.8 kA, and the validity of the design is confirmed by the experimental results.
Fetal Heart Sounds Detection Using Wavelet Transform and Fractal Dimension
Koutsiana, Elisavet; Hadjileontiadis, Leontios J.; Chouvarda, Ioanna; Khandoker, Ahsan H.
2017-01-01
Phonocardiography is a non-invasive technique for the detection of fetal heart sounds (fHSs). In this study, analysis of fetal phonocardiograph (fPCG) signals, in order to achieve fetal heartbeat segmentation, is proposed. The proposed approach (namely WT–FD) is a wavelet transform (WT)-based method that combines fractal dimension (FD) analysis in the WT domain for the extraction of fHSs from the underlying noise. Its adoption in this field stems from its successful use in the fields of lung and bowel sounds de-noising analysis. The efficiency of the WT–FD method in fHS extraction has been evaluated with 19 simulated fHS signals, created for the present study, with additive noise up to (3 dB), along with the simulated fPCGs database available at PhysioBank. Results have shown promising performance in the identification of the correct location and morphology of the fHSs, reaching an overall accuracy of 89% justifying the efficacy of the method. The WT–FD approach effectively extracts the fHS signals from the noisy background, paving the way for testing it in real fHSs and clearly contributing to better evaluation of the fetal heart functionality. PMID:28944222
Investigation of DC hybrid circuit breaker based on high-speed switch and arc generator.
Wu, Yifei; Rong, Mingzhe; Wu, Yi; Yang, Fei; Li, Mei; Zhong, Jianying; Han, Guohui; Niu, Chunping; Hu, Yang
2015-02-01
A new design of DC hybrid circuit breaker based on high-speed switch (HSS) and arc generator (AG), which can drastically profit from low heat loss in normal state and fast current breaking under fault state, is presented and analyzed in this paper. AG is designed according to the magnetic pinch effect of liquid metal. By utilizing the arc voltage generated across AG, the fault current is rapidly commutated from HSS into parallel connected branch. As a consequence, the arcless open of HSS is achieved. The post-arc conducting resume time (Δ tc) of AG and the commutation original voltage (Uc), two key factors in the commutation process, are investigated experimentally. Particularly, influences of the liquid metal channel diameter (Φ) of AG, fault current rate of rise (di/dt) and Uc on Δ tc are focused on. Furthermore, a suitable Uc is determined during the current commutation process, aiming at the reliable arcless open of HSS and short breaking time. Finally, the fault current breaking test is carried out for the current peak value of 11.8 kA, and the validity of the design is confirmed by the experimental results.
Problem of unity of measurements in ensuring safety of hydraulic structures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kheifits, V.Z.; Markov, A.I.; Braitsev, V.V.
1994-07-01
Ensuring the safety of hydraulic structures (HSs) is not only an industry but also a national and global concern, since failure of large water impounding structures can entail large losses of lives and enormous material losses related to destruction downstream. The main information on the degree of safety of a structure is obtained by comparing information about the actual state of the structure obtained on the basis of measurements in key zones of the structure with the predicted state on basis of the design model used when designing the structure for given conditions of external actions. Numerous, from hundreds tomore » thousands, string type transducers are placed in large HSs. This system of transducers monitor the stress-strain rate, seepage, and thermal regimes. These measurements are supported by the State Standards Committee which certifies the accuracy of the checking methods. To improve the instrumental monitoring of HSs, the author recommends: Calibration of methods and means of reliable diagnosis for each measuring channel in the HS, improvements to reduce measurement error, support for the system software programs, and development of appropriate standards for the design and examination of HSs.« less
Sandwich-like C@SnO2/Sn/void@C hollow spheres as improved anode materials for lithium ion batteries
NASA Astrophysics Data System (ADS)
Wang, Huijun; Jiang, Xinya; Chai, Yaqin; Yang, Xia; Yuan, Ruo
2018-03-01
As lithium ion batteries (LIBs) anode, SnO2 suffers fast capacity fading due to its large volume expansion during discharge/charge process. To overcome the problem, sandwich-like C@SnO2/Sn/void@C hollow spheres (referred as C@SnO2/Sn/void@C HSs) are prepared by in-situ polymerization and carbonization, using hollow SnO2 as self-template and dopamine as carbon source. The C@SnO2/Sn/void@C HSs possesses the merits of hollow and core/void/shell structure, so that they can accommodate the volume change under discharge/charge process, shorten the transmission distance of Li ions, own more contact area for the electrolyte. Thanks to these advantages, C@SnO2/Sn/void@C HSs display excellent electrochemical performance as anode materials for LIBs, which deliver a high capacity of 786.7 mAh g-1 at the current density of 0.5 A g-1 after 60 cycles. The simple synthesis method for C@SnO2/Sn/void@C HSs with special structure will provide a promising method for preparing other anode materials for LIBs.
Cuya, Teobaldo; Baptista, Leonardo; Celmar Costa França, Tanos
2017-11-23
Components of ginger (Zingiber officinale) extracts have been described as potential new drug candidates against Alzheimer disease (AD), able to interact with several molecular targets related to the AD treatment. However, there are very few theoretical studies in the literature on the possible mechanisms of action by which these compounds can work as potential anti-AD drugs. For this reason, we performed here docking, molecular dynamic simulations and mmpbsa calculations on four components of ginger extracts former reported as active inhibitors of human acetylcholinesterase (HssAChE), and compared our results to the known HssAChE inhibitor and commercial drug in use against AD, donepezil (DNP). Our findings points to two among the compounds studied: (E)-1,7-bis(4-hydroxy-3-methoxyphenyl)hept-4-en-3-on and 1-(3,4-dihydroxy-5-methoxyphenyl)-7-(4-hydroxy-3- ethoxyphenyl) heptane-3,5-diyl diacetate, as promising new HssAChE inhibitors that could be as effective as DNP. We also mapped the binding of the studied compounds in the different binding pockets inside HssAChE and established the preferred interactions to be favored in the design of new and more efficient inhibitors.
Plasma-Mediated Release of Morphine from Synthesized Prodrugs
2013-01-01
UPLC )9 (Waters Inc.) was utilized for measurements of morphine, PDA and PDB. UPLC has the capability to perform rapid (< 10 min) and reproducible...for UPLC versus ~30-50 µL for HPLC. The term “morphine” refers to the free morphine alkaloid base (Malinkrodt, etc.) unless otherwise stated...Baseline UPLC profiles were obtained for phosphate buffered saline (PBS), morphine and PDA in esterase de-activated plasma. Plasma was precipitated by the
Hallermann-Streiff syndrome with hypopituitarism contributing to growth failure.
Pivnick, E K; Burstein, S; Wilroy, R S; Kaufman, R A; Ward, J C
1991-12-15
A 35-month-old black boy with Hallermann-Streiff syndrome (HSS) was evaluated for anterior hypopituitarism when he presented with ketotic hypoglycemia, microgenitalia, and short stature. Endocrine evaluation showed a low T4 and TSH levels, suggesting hypothalamic hypothyroidism; this was confirmed by TRH stimulation. Metyrapone test confirmed ACTH deficiency as a contributing factor to the ketotic hypoglycemia. A superagonist GnRH test suggested hypothalamic GnRH deficiency. Growth hormone provocative testing conclusively demonstrated complete growth hormone deficiency. MRI investigation of the brain suggested hypopituitarism. Although facial findings were not completely classical of the HSS, we suggest these may be somewhat altered due to his racial back-ground. We recommend endocrine evaluation of HSS patients with manifestations suggesting hypopituitarism since treatment of this condition will improve the quality of life of these patients.
Trezza, C; Mazzotta, M; Lorenzetti, D; De Vito, L; Renzini, V
2018-01-01
In the Azienda Ospedaliera Universitaria Policlinico Umberto I in Rome, the Hospital Social Services (HSS) is located within the Directorate of Health, reporting directly to the Chief Medical Officer, providing counselling and supporting clinical services. The HSS is part of a network with its own technical, professional and assessment independence. It often serves as liaison between the hospital and the territory, facilitating the development of services and contributing to public health recovery and maintenance, therefore improving the citizens' standard of living thanks to aid projects and specific interventions. The present Report is based on two different studies carried out in 2008 and 2014, both examining the work of the Hospital Social Service in the "Azienda Ospedaliera Universitaria Policlinico Umberto I" in Rome. The purpose is to compare these surveys and work out the results. The data collection is based on a number of social records from the HSS archives (814 records in 2008 and 790 in 2014). The research project followed subsequent stages: planning a draft of the research, where ethnomethodology was used as empirical evaluation technique; collecting data from the HSS's paper and file archives (biographical, clinical and social data); revising, analysing and elaborating the data which showed relevant changes leading to interesting conclusions. The comparative analysis of data showed a higher demand of HSS healthcare services, despite a smaller number of beds and hospitalisations available in standard regime. Also, it indicated an increase of patients below 18 years and a decrease of the over-65s age group. As for the geographical origin of patients reported to the HSS, there was a decrease in the percentage of Italian citizens, while the percentage of irregular non-EU and EU patients increased by over 5%. Significant results were found comparing the days between the report to the HSS and patient discharge. Data concerning the 'more than 7 days' group was steady over the years, being more consistent for both the variables considered and increasing in 2014. In the comparative analysis, the interventions with more significant differences were those aimed at promoting homecare and entering sheltered housing. In the former cases, a considerable decrease was observed, if compared to the activation of the integrated health and social homecare services, while there were more requests for homecare assistance; in the latter ones the analysis highlighted a sharp decrease in the percentage of the variable called "assessment to enter Extended Care Units". The causes of these changes are remarkable and have to be found in the political, historical and cultural scenario: - a first factor is the increase in the more recent migratory flow from non-EU countries to Italy, which could explain the rising percentage of foreigners taken over by the HSS; - regional policies, economic cuts imposed on healthcare and higher income limits in order to calculate the patient's economic participation in the costs of institutionalisation have affected the above-mentioned changes; - the innovations in the regulatory field of Latium Region have brought structural changes in long-term care facilities and in the level of care in Extended Care Units (ECU).
Comparison of UPLC and HPLC methods for determination of vitamin C.
Klimczak, Inga; Gliszczyńska-Świgło, Anna
2015-05-15
Ultra performance liquid chromatography (UPLC) and high-performance liquid chromatography (HPLC) methods for determination of ascorbic acid (AA) and total AA (TAA) contents (as the sum of AA and dehydroascorbic acid (DHAA) after its reduction to AA) in fruit beverages and in pharmaceutical preparations were compared. Both methods are rapid: total time of analysis was 15 and 6 min for HPLC and UPLC methods, respectively. The methods were validated in terms of linearity, instrument precision, limits of detection (LOD) and quantification (LOQ), accuracy and recovery. Intra- and inter-day instrument precisions for fruit juices, expressed as RSD, were 2.2% and 2.4% for HPLC, respectively, and 1.7% and 1.9% for UPLC, respectively. For vitamin C tablets, inter- and intra-day precisions were 0.4% and 0.5%, respectively (HPLC), and 0.5% and 0.3%, respectively (UPLC). Both methods were sensitive: LOD was 0.049 μg/mL for HPLC and 0.024 μg/mL for UPLC while LOQs were 0.149 and 0.073 μg/mL for HPLC and UPLC, respectively. These methods could be useful in the routine qualitative and quantitative analysis of AA or TAA in pharmaceutical preparations or fruit beverages. However, UPLC method is more sensitive, faster and consumes less eluent. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sydor, O. M.
2016-09-01
The investigations of photoelectric characteristics and photoresponce spectral dependences were carried out for intrinsic oxide-InSe heterostructures (HSs) and their changes induced by bremsstrahlung γ-quanta with an energy of 1-34 MeV at fluences of 1012-1015 cm-2. The thermal oxidation of the p-InSe:Cd substrates was carried out at a temperature of 420 °С. For three selected groups of samples the duration of the process was 15 min, 60 min, and 96 h. At a short-term oxidation (15 and 60 min) a layer of In2O3 appears. The only difference between the samples of these two groups is a higher photosensitivity in the range of energy 1.25-2.8 eV of the HSs obtained after the 60 min oxidation. At the long-term oxidation the photoresponce spectra η(hν) of the obtained HSs are characterized with a sharp short-wavelength decrease at hν≅2.0 eV. It is established that the intrinsic oxide films act as transparent barrier electrodes in the corresponding HSs and are low-sensitive to γ-irradiation in the all range of fluences. The shape of the photoresponce spectra for all the gamma irradiated HSs remains practically the same. However, it was found: (i) some decrease of photosensitivity at the long-wavelength edge, (ii) decreasing the width of η(hν) at half-height, (iii) the appearance of the exciton peak, (iv) the improvement of a slope of the low-energy edge of the photoresponce spectra with increasing irradiation dose whereas at the maximum fluence this parameter decreases, and (v) the slight extension of the spectral sensitivity to the short-wavelength range for the structures obtained after oxidation for 96 h. The photoelectric parameters of the intrinsic oxide-p-InSe HSs, open circuit voltage Voc, short-circuit current Jsc, current SIλmax and voltage SVλmax sensitivities become only improved after irradiation with the fluences 1012-1013 cm-2. At the maximum fluence a small decreasing of the values of Voc and Jsc was detected except for the structures obtained after oxidation for 15 min. An increase of the SIλmax and SVλmax sensitivities in comparison with the initial value were found for all the HSs even at the maximum fluence except for the structures obtained by a long-term oxidation.
Employing the Army Health System Outside the Main Gate
2014-05-22
Publications and Forms , http://armypubs.army.mil/ doctrine/ADRP_1.html (accessed 5 September 2013), 2-10. 9...of the HSS and FHP missions for training, pre-deployment, deployment, and post-deployment operations. The AHS includes all mission support services...performed, provided, or arranged by the AMEDD to support HSS and FHP mission requirements for the Army and as directed, for joint, intergovernmental
From iconic handshapes to grammatical contrasts: longitudinal evidence from a child homesigner
Coppola, Marie; Brentari, Diane
2014-01-01
Many sign languages display crosslinguistic consistencies in the use of two iconic aspects of handshape, handshape type and finger group complexity. Handshape type is used systematically in form-meaning pairings (morphology): Handling handshapes (Handling-HSs), representing how objects are handled, tend to be used to express events with an agent (“hand-as-hand” iconicity), and Object handshapes (Object-HSs), representing an object's size/shape, are used more often to express events without an agent (“hand-as-object” iconicity). Second, in the distribution of meaningless properties of form (morphophonology), Object-HSs display higher finger group complexity than Handling-HSs. Some adult homesigners, who have not acquired a signed or spoken language and instead use a self-generated gesture system, exhibit these two properties as well. This study illuminates the development over time of both phenomena for one child homesigner, “Julio,” age 7;4 (years; months) to 12;8. We elicited descriptions of events with and without agents to determine whether morphophonology and morphosyntax can develop without linguistic input during childhood, and whether these structures develop together or independently. Within the time period studied: (1) Julio used handshape type differently in his responses to vignettes with and without an agent; however, he did not exhibit the same pattern that was found previously in signers, adult homesigners, or gesturers: while he was highly likely to use a Handling-HS for events with an agent (82%), he was less likely to use an Object-HS for non-agentive events (49%); i.e., his productions were heavily biased toward Handling-HSs; (2) Julio exhibited higher finger group complexity in Object- than in Handling-HSs, as in the sign language and adult homesigner groups previously studied; and (3) these two dimensions of language developed independently, with phonological structure showing a sign language-like pattern at an earlier age than morphosyntactic structure. We conclude that iconicity alone is not sufficient to explain the development of linguistic structure in homesign systems. Linguistic input is not required for some aspects of phonological structure to emerge in childhood, and while linguistic input is not required for morphology either, it takes time to emerge in homesign. PMID:25191283
On the Relationship Between High Speed Solar Wind Streams and Radiation Belt Electron Fluxes
NASA Technical Reports Server (NTRS)
Zheng, Yihua
2011-01-01
Both past and recent research results indicate that solar wind speed has a close connection to radiation belt electron fluxes [e.g., Paulikas and Blake, 1979; Reeves et aI., 2011]: a higher solar wind speed is often associated with a higher level of radiation electron fluxes. But the relationship can be very complex [Reeves et aI., 2011]. The study presented here provides further corroboration of this viewpoint by emphasizing the importance of a global perspective and time history. We find that all the events during years 2010 and 2011 where the >0.8 MeV integral electron flux exceeds 10(exp 5) particles/sq cm/sr/s (pfu) at GEO orbit are associated with the high speed streams (HSS) following the onset of the Stream Interaction Region (SIR), with most of them belonging to the long-lasting Corotating Interaction Region (CIR). Our preliminary results indicate that during HSS events, a maximum speed of 700 km/s and above is a sufficient but not necessary condition for the > 0.8 MeV electron flux to reach 10(exp 5) pfu. But in the exception cases of HSS events where the electron flux level exceeds the 10(exp 5) pfu value but the maximum solar wind speed is less than 700 km/s, a prior impact can be noted either from a CME or a transient SIR within 3-4 days before the arrival of the HSS - stressing the importance of time history. Through superposed epoch analysis and studies providing comparisons with the CME events and the HSS events where the flux level fails to reach the 10(exp 5) pfu, we will present the quantitative assessment of behaviors and relationships of various quantities, such as the time it takes to reach the flux threshold value from the stream interface and its dependence on different physical parameters (e.g., duration of the HSS event, its maximum or average of the solar wind speed, IMF Bz, Kp). The ultimate goal is to apply what is derived to space weather forecasting.
Vos, Xander G; Smit, Natalie; Endert, Erik; Brosschot, Jos F; Tijssen, Jan G P; Wiersinga, Wilmar M
2009-02-01
The evidence that stress may provoke Graves' hyperthyroidism in genetically susceptible subjects is substantial. Whether exposure to stress is related to the severity of thyrotoxicosis has not been studied. Advancing age is associated with not only less severe Graves' hyperthyroidism but also self-reported stress. We tested the hypothesis whether advancing age is associated with less exposure to stress, resulting in a lower immunological response, and less severe Graves' hyperthyroidism. Cross-sectional multicenter study. Two hundred and sixty-three consecutive untreated patients with a first episode of Graves' hyperthyroidism were included. The severity of Graves' hyperthyroidism was evaluated biochemically (freeT(4)-index and freeT(3)-index, thyrotropin-binding inhibitory immunoglobulin (TBII)) and clinically by the hyperthyroid symptom scale score (HSS score). Stress exposure was quantitated by three questionnaires. Advancing age was associated with less severe Graves' hyperthyroidism, both biochemically by lower serum freeT(3)-index and freeT(4)-index (P<0.01), lower serum TBII (P=0.05), and clinically by lower HSS scores (P=0.04) and smaller goiter size (P<0.01). FreeT(3)-index and freeT(4)-index were directly associated with HSS scores (P<0.01). Stress scores were associated with HSS scores (P<0.01) but not with biochemical severity of Graves' hyperthyroidism. Advancing age was associated with lower scores for stress exposure. Multivariate regression analysis showed that HSS score was independently related to the tendency to report negative feelings (P<0.01) but not to other stress scores and also not to age. Advancing age is associated with less exposure to stress, lower serum TBII and less severe clinical and biochemical Graves' hyperthyroidism. Because no direct relationship exists between stress exposure and TBII or freeT(3)-index and freeT(4)-index, we reject our hypothesis that less stress is causally related to biochemically less severe Graves' hyperthyroidism in old age. HSS score is primarily determined by negative feelings and not by age.
Xinyinqin: a computer-based heart sound simulator.
Zhan, X X; Pei, J H; Xiao, Y H
1995-01-01
"Xinyinqin" is the Chinese phoneticized name of the Heart Sound Simulator (HSS). The "qin" in "Xinyinqin" is the Chinese name of a category of musical instruments, which means that the operation of HSS is very convenient--like playing an electric piano with the keys. HSS is connected to the GAME I/O of an Apple microcomputer. The generation of sound is controlled by a program. Xinyinqin is used as a teaching aid of Diagnostics. It has been applied in teaching for three years. In this demonstration we will introduce the following functions of HSS: 1) The main program has two modules. The first one is the heart auscultation training module. HSS can output a heart sound selected by the student. Another program module is used to test the student's learning condition. The computer can randomly simulate a certain heart sound and ask the student to name it. The computer gives the student's answer an assessment: "correct" or "incorrect." When the answer is incorrect, the computer will output that heart sound again for the student to listen to; this process is repeated until she correctly identifies it. 2) The program is convenient to use and easy to control. By pressing the S key, it is able to output a slow heart rate until the student can clearly identify the rhythm. The heart rate, like the actual rate of a patient, can then be restored by hitting any key. By pressing the SPACE BAR, the heart sound output can be stopped to allow the teacher to explain something to the student. The teacher can resume playing the heart sound again by hitting any key; she can also change the content of the training by hitting RETURN key. In the future, we plan to simulate more heart sounds and incorporate relevant graphs.
Dassah, Edward Tieru; Adu-Sarkodie, Yaw; Mayaud, Philippe
2016-12-09
Use of treponemal tests to screen for syphilis (caused by Treponema pallidum pallidum) poses challenges with infection status classification, especially in settings where other treponemal infections are endemic. This study aimed to determine the validity of the syphilis surveillance testing strategy implemented since 2004 using two treponemal tests, and estimate the seroprevalence of active syphilis infection in Ghana where yaws (caused by Treponema pallidum pertenue) is endemic. We retested sera from the 2007 HIV sentinel survey (HSS) using a traditional algorithm, quantitative rapid plasma reagin test followed by qualitative Treponema pallidum haemagglutination assay. The adjusted seroprevalence of active syphilis was calculated by applying the proportions of active syphilis within identified categories of HSS samples during the retesting, to the entire population of HSS samples. The 95% confidence intervals (CIs) were calculated for each proportion, and the t-test was used to assess differences in proportions. Of 2,214 samples that were retested, 203 (9.2%) had active syphilis infection, 21 (0.9%) were biological false reactions, 640 (28.9%) were past or treated syphilis infections, and 1,350 (61%) were uninfected. The current syphilis testing strategy overestimated the seroprevalence of active syphilis infection by a third (HSS versus traditional algorithm: 6.0% (95% CI: 5.6-6.3) vs. 4.5% (95% CI: 4.2-4.8); p < 0.001), and had low positive predictive value (16.8%) for detecting active syphilis infection. More than half (51.9%) of HSS syphilis positive cases were actually past/treated treponemal infections, possibly previous exposure to yaws. There is an urgent need to review the current syphilis sentinel surveillance testing strategy in Ghana in the context of concurrent endemic treponematoses, to better inform policy.
Dansereau, Emily; Miangotar, Yodé; Squires, Ellen; Mimche, Honoré; El Bcheraoui, Charbel
2017-11-16
Since 2005, Gavi has provided health system strengthening (HSS) grants to address bottlenecks affecting immunization services. This study is the first to evaluate the Gavi HSS implementation process in either Cameroon or Chad, two countries with significant health system challenges and poor achievement on the child and maternal health Millennium Development Goals. We triangulated quantitative and qualitative data including financial records, document review, field visit questionnaires, and key informant interviews (KII) with representatives from the Ministries of Health, Gavi, and other partners. We conducted a Root Cause Analysis of key implementation challenges, guided by the Consolidated Framework for Implementation Research. We conducted 124 field visits and 43 KIIs in Cameroon, and 57 field visits and 39 KIIs in Chad. Cameroon's and Chad's HSS programs were characterized by delayed disbursements, significant deviations from approved expenditures, and reprogramming of funds. Nearly a year after the programs were intended to be complete, many district and facility-level activities were only partially implemented and significant funds remained unabsorbed. Root causes of these challenges included unpredictable Gavi processes and disbursements, poor communication between the countries and Gavi, insufficient country planning without adequate technical assistance, lack of country staff and leadership, and weak country systems to manage finances and promote institutional memory. Though Chad and Cameroon both critically needed support to strengthen their weak health systems, serious challenges drastically limited implementation of their Gavi HSS programs. Implementation of future HSS programs in these and similar settings can be improved by transparent and reliable procedures and communication from Gavi, proposals that account for countries' programmatic capacity and the potential for delayed disbursements, implementation practices that foster learning and adaptation, and an early emphasis on developing managerial and other human resources.
Gor, Kira
2014-01-01
Second language learners perform worse than native speakers under adverse listening conditions, such as speech in noise (SPIN). No data are available on heritage language speakers’ (early naturalistic interrupted learners’) ability to perceive SPIN. The current study fills this gap and investigates the perception of Russian speech in multi-talker babble noise by the matched groups of high- and low-proficiency heritage speakers (HSs) and late second language learners of Russian who were native speakers of English. The study includes a control group of Russian native speakers. It manipulates the noise level (high and low), and context cloze probability (high and low). The results of the SPIN task are compared to the tasks testing the control of phonology, AXB discrimination and picture-word discrimination, and lexical knowledge, a word translation task, in the same participants. The increased phonological sensitivity of HSs interacted with their ability to rely on top–down processing in sentence integration, use contextual cues, and build expectancies in the high-noise/high-context condition in a bootstrapping fashion. HSs outperformed oral proficiency-matched late second language learners on SPIN task and two tests of phonological sensitivity. The outcomes of the SPIN experiment support both the early naturalistic advantage and the role of proficiency in HSs. HSs’ ability to take advantage of the high-predictability context in the high-noise condition was mitigated by their level of proficiency. Only high-proficiency HSs, but not any other non-native group, took advantage of the high-predictability context that became available with better phonological processing skills in high-noise. The study thus confirms high-proficiency (but not low-proficiency) HSs’ nativelike ability to combine bottom–up and top–down cues in processing SPIN. PMID:25566130
Eskelinen, Matti; Korhonen, Riika; Selander, Tuomas; Ollonen, Paula
2015-03-01
The associations between emotional personality, proximity and authenticity in patient-physician communication during breast cancer (BC) consultations are rarely considered together in a prospective study. We, therefore, investigated emotional personality/proximity versus authenticity in patient-physician communication in healthy study subjects (HSS) and in patients with benign breast disease (BBD) and breast cancer (BC). In the Kuopio Breast Cancer Study, 115 women with breast symptoms were evaluated regarding emotional personality, proximity and authenticity in their a patient-physician communication before any diagnostic procedures were carried-out. The emotional personality and the emotional proximity in patient-physician communication was highly significantly positively correlated in the BBD group. The kappa-values for emotional personality versus emotional proximity in the HSS, BBD and BC groups were statistically significant. There was also a highly significant positive correlation between emotional personality and emotional authenticity in the HSS, BBD and BC groups and the kappa values in the HSS, BBD and BC groups were statistically significant. There was a highly significant positive correlation between emotional proximity and emotional authenticity in the BBD group, and the weighted kappa-values in the BBD group were statistically significant. The results of the present study support a powerful link between emotional personality/proximity and emotional authenticity, and provides new information in patient-physician communication in the HSS, BBD and BC groups. This finding is of clinical importance, since during breast disease consultation, barriers to patient-physician communication may be associated with difficulties in early BC diagnosis in the breast cancer diagnostic unit. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Fabrication of Photocatalytic Paper Using TiO2 Nanoparticles Confined in Hollow Silica Capsules.
Fujiwara, Kensei; Kuwahara, Yasutaka; Sumida, Yuki; Yamashita, Hiromi
2017-01-10
TiO 2 nanoparticles (NPs) encapsulated in hollow silica spheres (TiO 2 @HSSs) show a shielding-effect that can insulate photocatalytically active TiO 2 NPs from the surrounding environment and thus prohibit the self-degradation of organic support materials under ultraviolet (UV)-light irradiation. In this study, photocatalytically active papers were fabricated by combining TiO 2 @HSS and cellulose fibers, and their photocatalytic activities and durability under UV-light irradiation were examined. The yolk-shell nanostructured TiO 2 @HSS, which has an ample void space between inner TiO 2 NPs and an outer silica shell, was synthesized using a facile single-step method utilizing an oil-in-water microemulsion as an organic template. The thus-prepared TiO 2 @HSS particles were deposited onto a cellulose paper either by the chemical adhesion process via ionic bonding or by the physical adhesion process using a dual polymer system. The obtained paper containing TiO 2 @HSS particles with high air permeability exhibited a higher photocatalytic activity in the photocatalytic decomposition of volatile organic compounds than unsupported powdery TiO 2 @HSS particles because of the uniform dispersion on the paper with a reticular fiber network. In addition, the paper was hardly damaged under UV-light irradiation, whereas the paper containing naked TiO 2 NPs showed a marked deterioration with a considerably decreased strength, owing to the ability of the silica shell to prevent direct contact between TiO 2 and organic fibers. This study can offer a promising method to fabricate photocatalytically active papers with a photoresistance property available for real air cleaning.
Naimoli, Joseph F; Saxena, Sweta; Hatt, Laurel E; Yarrow, Kristina M; White, Trenton M; Ifafore-Calfee, Temitayo
2018-01-01
In 2013, Hafner and Shiffman applied Kingdon's public policy process model to explain the emergence of global attention to health system strengthening (HSS). They questioned, however, HSS's sustainability on the global health policy agenda, citing various concerns. Guided by the Grindle and Thomas interactive model of policy implementation, we advance and elaborate a proposition: a confluence of developments will contribute to maintaining HSS's prominent place on the agenda until at least 2030. Those developments include (1) technical, managerial, financial, and political responses to unpredictable public health crises that imperil the routine functioning of health systems, such as the 2014-2015 Ebola virus disease (Ebola) epidemic in West Africa; (2) similar responses to non-crisis situations requiring fully engaged, robust health systems, such as the pursuit of the new Sustainable Development Goal for health (SDG3); and (3) increased availability of new knowledge about system change at macro, meso, and micro levels and its effects on people's health and well-being. To gauge the accuracy of our proposition, we carried out a speculative assessment of credible threats to our premise by discussing all of the Hafner-Shiffman concerns. We conclude that (1) the components of our proposition and other forces that have the potential to promote continuing attention to HSS are of sufficient strength to counteract these concerns, and (2) prospective monitoring of HSS agenda status and further research on agenda sustainability can increase confidence in our threat assessment. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
A novel system for automated propofol sedation: hybrid sedation system (HSS).
Zaouter, Cedrick; Taddei, Riccardo; Wehbe, Mohamad; Arbeid, Erik; Cyr, Shantale; Giunta, Francesco; Hemmerling, Thomas M
2017-04-01
Closed-loop systems for propofol have been demonstrated to be safe and reliable for general anesthesia. However, no study has been conducted using a closed-loop system specifically designed for sedation in patients under spinal anesthesia. We developed an automatic anesthesia sedation system that allows for closed-loop delivery of propofol for sedation integrating a decision support system, called the hybrid sedation system (HSS). The objective of this study is to compare this system with standard practice. One hundred fifty patients were enrolled and randomly assigned to two groups: HSS-Group (N = 75), in which propofol was administered using a closed-loop system; Control Group (N = 75), in which propofol was delivered manually. The clinical performance of the propofol sedation control is defined as efficacy to maintain bispectral index (BIS) near 65. The clinical control was called 'Excellent', 'Good', 'Poor' and 'Inadequate' with BIS values within 10 %, from 11 to 20 %, 21 to 30 %, or greater than 30 % of the BIS target of 65, respectively. The controller performance was evaluated using Varvel's parameters. Data are presented as mean ± standard deviation, groups were compared using t test or Chi square test, P < 0.05. Clinical performance of sedation showed 'Excellent' control in the HSS-group for a significantly longer period of time (49 vs. 26 % in the control group, P < 0.0001). 'Poor' and 'Inadequate' sedation was significantly shorter in the HSS Group compared to the Control Group (11 and 10 % vs. 20 and 18 %, respectively, P < 0.0001). The novel, closed-loop system for propofol sedation showed better maintenance of the target BIS value compared to manual administration.
Sinkala, Edford; Zyambo, Kanekwa; Besa, Ellen; Kaonga, Patrick; Nsokolo, Bright; Kayamba, Violet; Vinikoor, Michael; Zulu, Rabison; Bwalya, Martin; Foster, Graham R; Kelly, Paul
2018-04-01
Cirrhosis is the dominant cause of portal hypertension globally but may be overshadowed by hepatosplenic schistosomiasis (HSS) in the tropics. In Zambia, schistosomiasis seroprevalence can reach 88% in endemic areas. Bacterial translocation (BT) drives portal hypertension in cirrhosis contributing to mortality but remains unexplored in HSS. Rifaximin, a non-absorbable antibiotic may reduce BT. We aimed to explore the influence of rifaximin on BT, inflammation, and fibrosis in HSS. In this phase II open-label trial (ISRCTN67590499), 186 patients with HSS in Zambia were evaluated and 85 were randomized to standard care with or without rifaximin for 42 days. Changes in markers of inflammation, BT, and fibrosis were the primary outcomes. BT was measured using plasma 16S rRNA, lipopolysaccharide-binding protein, and lipopolysaccharide, whereas hyaluronan was used to measure fibrosis. Tumor necrosis factor receptor 1 (TNFR1) and soluble cluster of differentiation 14 (sCD14) assessed inflammation. 16S rRNA reduced from baseline (median 146 copies/µL, interquartile range [IQR] 9, 537) to day 42 in the rifaximin group (median 63 copies/µL, IQR 12, 196), P < 0.01. The rise in sCD14 was lower ( P < 0.01) in the rifaximin group (median rise 122 ng/mL, IQR-184, 783) than in the non-rifaximin group (median rise 832 ng/mL, IQR 530, 967). TNFR1 decreased ( P < 0.01) in the rifaximin group (median -39 ng/mL IQR-306, 563) but increased in the non-rifaximin group (median 166 ng/mL, IQR 3, 337). Other markers remained unaffected. Rifaximin led to a reduction of inflammatory markers and bacterial 16S rRNA which may implicate BT in the inflammation in HSS.
Sinkala, Edford; Zyambo, Kanekwa; Besa, Ellen; Kaonga, Patrick; Nsokolo, Bright; Kayamba, Violet; Vinikoor, Michael; Zulu, Rabison; Bwalya, Martin; Foster, Graham R.; Kelly, Paul
2018-01-01
Abstract. Cirrhosis is the dominant cause of portal hypertension globally but may be overshadowed by hepatosplenic schistosomiasis (HSS) in the tropics. In Zambia, schistosomiasis seroprevalence can reach 88% in endemic areas. Bacterial translocation (BT) drives portal hypertension in cirrhosis contributing to mortality but remains unexplored in HSS. Rifaximin, a non-absorbable antibiotic may reduce BT. We aimed to explore the influence of rifaximin on BT, inflammation, and fibrosis in HSS. In this phase II open-label trial (ISRCTN67590499), 186 patients with HSS in Zambia were evaluated and 85 were randomized to standard care with or without rifaximin for 42 days. Changes in markers of inflammation, BT, and fibrosis were the primary outcomes. BT was measured using plasma 16S rRNA, lipopolysaccharide-binding protein, and lipopolysaccharide, whereas hyaluronan was used to measure fibrosis. Tumor necrosis factor receptor 1 (TNFR1) and soluble cluster of differentiation 14 (sCD14) assessed inflammation. 16S rRNA reduced from baseline (median 146 copies/µL, interquartile range [IQR] 9, 537) to day 42 in the rifaximin group (median 63 copies/µL, IQR 12, 196), P < 0.01. The rise in sCD14 was lower (P < 0.01) in the rifaximin group (median rise 122 ng/mL, IQR-184, 783) than in the non-rifaximin group (median rise 832 ng/mL, IQR 530, 967). TNFR1 decreased (P < 0.01) in the rifaximin group (median -39 ng/mL IQR-306, 563) but increased in the non-rifaximin group (median 166 ng/mL, IQR 3, 337). Other markers remained unaffected. Rifaximin led to a reduction of inflammatory markers and bacterial 16S rRNA which may implicate BT in the inflammation in HSS. PMID:29436337
A portable high-speed camera system for vocal fold examinations.
Hertegård, Stellan; Larsson, Hans
2014-11-01
In this article, we present a new portable low-cost system for high-speed examinations of the vocal folds. Analysis of glottal vibratory parameters from the high-speed recordings is compared with videostroboscopic recordings. The high-speed system is built around a Fastec 1 monochrome camera, which is used with newly developed software, High-Speed Studio (HSS). The HSS has options for video/image recording, contains a database, and has a set of analysis options. The Fastec/HSS system has been used clinically since 2011 in more than 2000 patient examinations and recordings. The Fastec 1 camera has sufficient time resolution (≥4000 frames/s) and light sensitivity (ISO 3200) to produce images for detailed analyses of parameters pertinent to vocal fold function. The camera can be used with both rigid and flexible endoscopes. The HSS software includes options for analyses of glottal vibrations, such as kymogram, phase asymmetry, glottal area variation, open and closed phase, and angle of vocal fold abduction. It can also be used for separate analysis of the left and vocal fold movements, including maximum speed during opening and closing, a parameter possibly related to vocal fold elasticity. A blinded analysis of 32 patients with various voice disorders examined with both the Fastec/HSS system and videostroboscopy showed that the high-speed recordings were significantly better for the analysis of glottal parameters (eg, mucosal wave and vibration asymmetry). The monochrome high-speed system can be used in daily clinical work within normal clinical time limits for patient examinations. A detailed analysis can be made of voice disorders and laryngeal pathology at a relatively low cost. Copyright © 2014 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Modeling free energy availability from Hadean hydrothermal systems to the first metabolism.
Simoncini, E; Russell, M J; Kleidon, A
2011-12-01
Off-axis Hydrothermal Systems (HSs) are seen as the possible setting for the emergence of life. As the availability of free energy is a general requirement to drive any form of metabolism, we ask here under which conditions free energy generation by geologic processes is greatest and relate these to the conditions found at off-axis HSs. To do so, we present a conceptual model in which we explicitly capture the energetics of fluid motion and its interaction with exothermic reactions to maintain a state of chemical disequilibrium. Central to the interaction is the temperature at which the exothermic reactions take place. This temperature not only sets the equilibrium constant of the chemical reactions and thereby the distance of the actual state to chemical equilibrium, but these reactions also shape the temperature gradient that drives convection and thereby the advection of reactants to the reaction sites and the removal of the products that relate to geochemical free energy generation. What this conceptual model shows is that the positive feedback between convection and the chemical kinetics that is found at HSs favors a greater rate of free energy generation than in the absence of convection. Because of the lower temperatures and because the temperature of reactions is determined more strongly by these dynamics rather than an external heat flux, the conditions found at off-axis HSs should result in the greatest rates of geochemical free energy generation. Hence, we hypothesize from these thermodynamic considerations that off-axis HSs seem most conducive for the emergence of protometabolic pathways as these provide the greatest, abiotic generation rates of chemical free energy.
Johnson, Oliver K.; Kurniawan, Christian
2018-02-03
Properties closures delineate the theoretical objective space for materials design problems, allowing designers to make informed trade-offs between competing constraints and target properties. In this paper, we present a new algorithm called hierarchical simplex sampling (HSS) that approximates properties closures more efficiently and faithfully than traditional optimization based approaches. By construction, HSS generates samples of microstructure statistics that span the corresponding microstructure hull. As a result, we also find that HSS can be coupled with synthetic polycrystal generation software to generate diverse sets of microstructures for subsequent mesoscale simulations. Finally, by more broadly sampling the space of possible microstructures, itmore » is anticipated that such diverse microstructure sets will expand our understanding of the influence of microstructure on macroscale effective properties and inform the construction of higher-fidelity mesoscale structure-property models.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Oliver K.; Kurniawan, Christian
Properties closures delineate the theoretical objective space for materials design problems, allowing designers to make informed trade-offs between competing constraints and target properties. In this paper, we present a new algorithm called hierarchical simplex sampling (HSS) that approximates properties closures more efficiently and faithfully than traditional optimization based approaches. By construction, HSS generates samples of microstructure statistics that span the corresponding microstructure hull. As a result, we also find that HSS can be coupled with synthetic polycrystal generation software to generate diverse sets of microstructures for subsequent mesoscale simulations. Finally, by more broadly sampling the space of possible microstructures, itmore » is anticipated that such diverse microstructure sets will expand our understanding of the influence of microstructure on macroscale effective properties and inform the construction of higher-fidelity mesoscale structure-property models.« less
Pseudo-bi-enzyme glucose sensor: ZnS hollow spheres and glucose oxidase concerted catalysis glucose.
Shuai, Ying; Liu, Changhua; Wang, Jia; Cui, Xiaoyan; Nie, Ling
2013-06-07
This work creatively uses peroxidase-like ZnS hollow spheres (ZnS HSs) to cooperate with glucose oxidase (GOx) for glucose determinations. This approach is that the ZnS HSs electrocatalytically oxidate the enzymatically generated H2O2 to O2, and then the O2 circularly participates in the previous glucose oxidation by glucose oxidase. Au nanoparticles (AuNPs) and carbon nanotubes (CNTs) are used as electron transfer and enzyme immobilization matrices, respectively. The biosensor of glucose oxidase-carbon nanotubes-Au nanoparticles-ZnS hollow spheres-gold electrode (GOx-CNT-AuNPs-ZnS HSs-GE) exhibits a rapid response, a low detection limit (10 μM), a wide linear range (20 μM to 7 mM) as well as good anti-interference, long-term longevity and reproducibility.
Residence as a Diagnostic and Therapeutic Area - A Smart Home Approach.
Mielke, Corinna; Voss, Thorsten; Haux, Reinhold
2017-01-01
The "research apartment Halberstadtstraße" (HSS) in Braunschweig, Germany, is the attempt to realize a personal living environment as a room for diagnostics and therapy with the support of health-enabling and ambient assistive technologies (HEAAT). As a research tool, the HSS will enable the efficient implementation of new HEAAT and help in evaluating these under controlled real-life conditions. This new research tool will therefore be the missing link between artificial laboratory and complete real-life conditions. For a defined period, selected subjects can live in the HSS and experience the benefit of such a "Smart Home". The academic support in a real-life controlled living-environment enables continuous monitoring of behavior patterns and habits of healthy and ill persons, evaluation of new HEAAT, and conduction of requirements analysis and acceptance studies.
Lopez, Xavier Moles; Debeir, Olivier; Maris, Calliope; Rorive, Sandrine; Roland, Isabelle; Saerens, Marco; Salmon, Isabelle; Decaestecker, Christine
2012-09-01
Whole-slide scanners allow the digitization of an entire histological slide at very high resolution. This new acquisition technique opens a wide range of possibilities for addressing challenging image analysis problems, including the identification of tissue-based biomarkers. In this study, we use whole-slide scanner technology for imaging the proliferating activity patterns in tumor slides based on Ki67 immunohistochemistry. Faced with large images, pathologists require tools that can help them identify tumor regions that exhibit high proliferating activity, called "hot-spots" (HSs). Pathologists need tools that can quantitatively characterize these HS patterns. To respond to this clinical need, the present study investigates various clustering methods with the aim of identifying Ki67 HSs in whole tumor slide images. This task requires a method capable of identifying an unknown number of clusters, which may be highly variable in terms of shape, size, and density. We developed a hybrid clustering method, referred to as Seedlink. Compared to manual HS selections by three pathologists, we show that Seedlink provides an efficient way of detecting Ki67 HSs and improves the agreement among pathologists when identifying HSs. Copyright © 2012 International Society for Advancement of Cytometry.
Zeng, Fangxinyu; Chen, Jinyao; Yang, Feng; Kang, Jian; Cao, Ya; Xiang, Ming
2018-01-16
In this study, polyamide-aluminum foil-polypropylene (PA-Al-PP) composite films with different orientation status of the PP layer were prepared, and their morphology, tensile, peeling and heat seal behavior were studied. The comparative study of tensile and fracture behaviors of single-layer film of PA, Al and PP, as well as the composite films of PA-Al, PP-Al and PA-Al-PP revealed that in PA-Al-PP composite film, the PA layer with the highest tensile strength can share the tensile stress from the Al layer during stretching, while the PP layer with the lowest tensile strength can prevent further development of the small cracks on boundary of the Al layer during stretching. Moreover, the study of heat seal behavior suggested that both the orientation status and the heat seal conditions were important factors in determining the heat seal strength ( HSS ) and failure behavior of the sample. Four failure types were observed, and a clear correspondence between HSS and failure types was found. The results also elucidated that for the composite film, only in the cases where the tensile stress was efficiently released by each layer during HSS measurement could the composite film exhibit desired high HSS that was even higher than its tensile strength.
Perceived message sensation value (PMSV) and the dimensions and validation of a PMSV scale.
Palmgreen, Philip; Stephenson, Michael T; Everett, Maureen W; Baseheart, John R; Francies, Regina
2002-01-01
Sensation seeking has been linked to drug abuse and risky behaviors, and is positively associated with preferences for messages high in sensation value (i.e., perceived to be highly novel, arousing, dramatic, or intense). This suggests the utility of valid and reliable measures of perceived message sensation value (PMSV) in research on information processing, persuasion, and reducing risk-related behaviors. Dimensions and construct validity of a 17-item PMSV scale were examined via 2 studies: 1 of 368 high school students' reactions to televised antimarijuana public service announcements (PSAs) and one of 444 college students' responses to televised anticocaine PSAs. Exploratory and confirmatory factor analyses indicated 3-dimensional solutions for the PMSV scale were nearly identical for high sensation seeking (HSS) and low sensation seeking (LSS) respondents in Study 1 and HSS respondents in Study 2. Total scale alphas were .87 for Study 1 and .93 for Study 2. The PMSV scale and its dimensions (Emotional Arousal, Dramatic Impact, Novelty) were positively correlated with affective response measures in both studies for HSS and LSS. Study 1 also examined cognitive, narrative, and sensory PSA processing, which were found to be positively associated with total PMSV and the Arousal and Dramatic Impact dimensions of PSMV for both HSS and LSS.
García, Andrés Calderín; de Souza, Luiz Gilberto Ambrosio; Pereira, Marcos Gervasio; Castro, Rosane Nora; García-Mina, José María; Zonta, Everaldo; Lisboa, Francy Junior Gonçalves; Berbara, Ricardo Luis Louro
2016-01-01
Knowledge of the structure-property-function relationship of humic substances (HSs) is key for understanding their role in soil. Despite progress, studies on this topic are still under discussion. We analyzed 37 humic fractions with respect to their isotopic composition, structural characteristics, and properties responsible for stimulating plant root parameters. We showed that regardless of the source of origin of the carbon (C3 or C4), soil-extracted HSs and humic acids (HAs) are structurally similar to each other. The more labile and functionalized HS fraction is responsible for root emission, whereas the more recalcitrant and less functionalized HA fraction is related to root growth. Labile structures promote root stimulation at lower concentrations, while recalcitrant structures require higher concentrations to promote a similar stimulus. These findings show that lability and recalcitrance, which are derived properties of humic fractions, are related to the type and intensity of their bioactivity. In summary, the comparison of humic fractions allowed a better understanding of the relationship between the source of origin of plant carbon and the structure, properties, and type and intensity of the bioactivity of HSs in plants. In this study, scientific concepts are unified and the basis for the agronomic use of HSs is established. PMID:26862010
Churchwell, Mona I; Twaddle, Nathan C; Meeker, Larry R; Doerge, Daniel R
2005-10-25
Recent technological advances have made available reverse phase chromatographic media with a 1.7 microm particle size along with a liquid handling system that can operate such columns at much higher pressures. This technology, termed ultra performance liquid chromatography (UPLC), offers significant theoretical advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometers capable of high-speed acquisitions. This paper explores the differences in LC-MS performance by conducting a side-by-side comparison of UPLC for several methods previously optimized for HPLC-based separation and quantification of multiple analytes with maximum throughput. In general, UPLC produced significant improvements in method sensitivity, speed, and resolution. Sensitivity increases with UPLC, which were found to be analyte-dependent, were as large as 10-fold and improvements in method speed were as large as 5-fold under conditions of comparable peak separations. Improvements in chromatographic resolution with UPLC were apparent from generally narrower peak widths and from a separation of diastereomers not possible using HPLC. Overall, the improvements in LC-MS method sensitivity, speed, and resolution provided by UPLC show that further advances can be made in analytical methodology to add significant value to hypothesis-driven research.
Ludwig, Katelyn R.; Sun, Liangliang; Zhu, Guijie; Dovichi, Norman J.; Hummon, Amanda B.
2015-01-01
Ultra-performance liquid chromatography (UPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) is typically employed for phosphoproteome analysis. Alternatively, capillary zone electrophoresis (CZE) - ESI-MS/MS has great potential for phosphoproteome analysis due to the significantly different migration times of phosphorylated and unphosphorylated forms of peptides. In this work, we systematically compared UPLC-MS/MS and CZE-MS/MS for phosphorylated peptide identifications (IDs) using an enriched phosphoproteome from the MCF-10A cell line. When the sample loading amount of UPLC was 10 times higher than that of CZE (2 μg vs. 200 ng), UPLC generated more phosphorylated peptide IDs than CZE (3,313 vs. 1,783). However, when the same sample loading amounts were used for CZE and UPLC (2–200 ng), CZE-MS/MS consistently and significantly outperformed UPLC-MS/MS in terms of phosphorylated peptide and total peptide IDs. This superior performance is most likely due to the higher peptide intensity generated by CZE-MS/MS. More importantly, compared with UPLC data from 2 μg sample, CZE-MS/MS can identify over 500 unique phosphorylated peptides from 200 ng sample, suggesting that CZE and UPLC are complementary for phosphorylated peptide IDs. With further improved loading capacity via a dynamic pH junction method, 2,313 phosphorylated peptides were identified with single-shot CZE-MS/MS in a 100 min analysis. This number of phosphorylated peptide IDs is over one order of magnitude higher than the number of phosphorylated peptide IDs previously reported by single-shot CZE-MS/MS. PMID:26399161
Miranda, Tiago A; Silva, Pedro H R; Pianetti, Gerson A; César, Isabela C
2015-01-28
Chloroquine and primaquine are the first-line treatment recommended by World Health Organization for malaria caused by Plasmodium vivax. Since the problem of counterfeit or substandard anti-malarials is well established all over the world, the development of rapid and reliable methods for quality control analysis of these drugs is essential. Thus, the aim of this study was to develop and validate a novel UPLC-DAD method for simultaneously quantifying chloroquine and primaquine in tablet formulations. The UPLC separation was carried out using a Hypersil C18 column (50 × 2.1 mm id; 1.9 μm particle size) and a mobile phase composed of acetonitrile (A) and 0.1% aqueous triethylamine, pH 3.0 adjusted with phosphoric acid (B), at a flow rate 0.6 mL/min. Gradient elution was employed. UV detection was performed at 260 nm. UPLC method was fully validated and the results were compared to a conventional HPLC-DAD method for the analysis of chloroquine and primaquine in tablet formulations. UPLC method was shown to be linear (r2 > 0.99), precise (CV < 2.0%), accurate (recovery rates from 98.11 to 99.83%), specific, and robust. No significant differences were observed between the chloroquine and primaquine contents obtained by UPLC and HPLC methods. However, UPLC method promoted faster analyses, better chromatographic performance and lower solvent consumption. The developed UPLC method was shown to be a rapid and suitable technique to quantify chloroquine and primaquine in pharmaceutical preparations and may be successfully employed for quality control analysis.
Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A.; Chen, Hao
2015-01-01
This study presents the development of ultra-performance liquid chromatography/mass spectrometry (UPLC/MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of disulfide bond-containing proteins/peptides. In our approach, a protein/peptide mixture sample undergoes fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and MS/MS analyses. The electrochemical cell is coupled to MS using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, disulfide bond-containing peptides can be differentiated from those without disulfide bonds as the former are electroactive and reducible. Tandem MS analysis of the disulfide-reduced peptide ions provides increased sequence and disulfide linkage pattern information. In a reactive DESI-MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which would be useful in top-down protein structure analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1~2 orders of magnitude by using UPLC for the LC/EC/MS platform, in comparison to the previously used high performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis. PMID:26307715
ERIC Educational Resources Information Center
Johnson, Eboneé T.; Yaghmaian, Rana A.; Best, Andrew; Chan, Fong; Burrell, Reginald, Jr.
2016-01-01
Purpose: The purpose of this study was to validate the 10-item version of the HIV Stigma Scale (HSS-10) in a sample of African Americans with HIV/AIDS. Method: One hundred and ten African Americans living with HIV/AIDS were recruited from 3 case management agencies in Baton Rouge, Louisiana. Measurement structure of the HSS-10 was evaluated using…
A novel isoflavone profiling method based on UPLC-PDA-ESI-MS.
Zhang, Shuang; Zheng, Zong-Ping; Zeng, Mao-Mao; He, Zhi-Yong; Tao, Guan-Jun; Qin, Fang; Chen, Jie
2017-03-15
A novel non-targeted isoflavone profiling method was developed using the diagnostic fragment-ion-based extension strategy, based on ultra-high performance liquid chromatography coupled with photo-diode array detector and electrospray ionization-mass spectrometry (UPLC-PDA-ESI-MS). 16 types of isoflavones were obtained in positive mode, but only 12 were obtained in negative mode due to the absence of precursor ions. Malonyldaidzin and malonylgenistin glycosylated at the 4'-O position or malonylated at the 4″-O position of glucose were indicated by their retention behavior and fragmentation pattern. Three possible quantification methods in one run based on UPLC-PDA and UPLC-ESI-MS were validated and compared, suggesting that methods based on UPLC-ESI-MS possess remarkable selectivity and sensitivity. Impermissible quantitative deviations induced by the linearity calibration with 400-fold dynamic range was observed for the first time and was recalibrated with a 20-fold dynamic range. These results suggest that isoflavones and their stereoisomers can be simultaneously determined by positive-ion UPLC-ESI-MS in soymilk. Copyright © 2016. Published by Elsevier Ltd.
Ok, Hyun Ee; Choi, Sung-Wook; Kim, Meehye; Chun, Hyang Sook
2014-11-15
High-performance liquid chromatography (HPLC) and ultra-performance liquid chromatography (UPLC) were compared to validate a method for determination of zearalenone (ZON) in noodles, cereal snacks, and infant formulas. The limits of detection and quantification in HPLC and UPLC were found to be 4.0 and 13.0 μg kg(-1) and 2.5 and 8.3 μg kg(-1), respectively. The average recoveries of ZON by HPLC and UPLC ranged from 79.1% to 105.3% and from 85.1% to 114.5%, respectively. The measurement uncertainties of the two methods for ZON determination were within the maximum standard uncertainty. The two methods showed that the levels of ZON in 163 naturally contaminated samples ranged from 4.3 to 8.3 μg kg(-1) by HPLC and 3.1 to 17.6 μg kg(-1) by UPLC. These findings indicate that either method is suitable for the determination of ZON in noodles, cereal snacks, and infant formulas, but UPLC gives faster results with better sensitivity. Copyright © 2014 Elsevier Ltd. All rights reserved.
Validation of an ultra-fast UPLC-UV method for the separation of antituberculosis tablets.
Nguyen, Dao T-T; Guillarme, Davy; Rudaz, Serge; Veuthey, Jean-Luc
2008-04-01
A simple method using ultra performance LC (UPLC) coupled with UV detection was developed and validated for the determination of antituberculosis drugs in combined dosage form, i. e. isoniazid (ISN), pyrazinamide (PYR) and rifampicin (RIF). Drugs were separated on a short column (2.1 mm x 50 mm) packed with 1.7 mum particles, using an elution gradient procedure. At 30 degrees C, less than 2 min was necessary for the complete separation of the three antituberculosis drugs, while the original USP method was performed in 15 min. Further improvements were obtained with the combination of UPLC and high temperature (up to 90 degrees C), namely HT-UPLC, which allows the application of higher mobile phase flow rates. Therefore, the separation of ISN, PYR and RIF was performed in less than 1 min. After validation (selectivity, trueness, precision and accuracy), both methods (UPLC and HT-UPLC) have proven suitable for the routine quality control analysis of antituberculosis drugs in combined dosage form. Additionally, a large number of samples per day can be analysed due to the short analysis times.
Iyer, Hari S; Hirschhorn, Lisa R; Nisingizwe, Marie Paul; Kamanzi, Emmanuel; Drobac, Peter C; Rwabukwisi, Felix C; Law, Michael R; Muhire, Andrew; Rusanganwa, Vincent; Basinga, Paulin
2017-01-01
Evaluations of health systems strengthening (HSS) interventions using observational data are rarely used for causal inference due to limited data availability. Routinely collected national data allow use of quasi-experimental designs such as interrupted time series (ITS). Rwanda has invested in a robust electronic health management information system (HMIS) that captures monthly healthcare utilization data. We used ITS to evaluate impact of an HSS intervention to improve primary health care facility readiness on health service utilization in two rural districts of Rwanda. We used controlled ITS analysis to compare changes in healthcare utilization at health centers (HC) that received the intervention (n = 13) to propensity score matched non-intervention health centers in Rwanda (n = 86) from January 2008 to December 2012. HC support included infrastructure renovation, salary support, medical equipment, referral network strengthening, and clinical training. Baseline quarterly mean outpatient visit rates and population density were used to model propensity scores. The intervention began in May 2010 and was implemented over a twelve-month period. We used monthly healthcare utilization data from the national Rwandan HMIS to study changes in the (1) number of facility deliveries per 10,000 women, (2) number of referrals for high risk pregnancy per 100,000 women, and (3) the number of outpatient visits performed per 1,000 catchment population. PHIT HC experienced significantly higher monthly delivery rates post-HSS during the April-June season than comparison (3.19/10,000, 95% CI: [0.27, 6.10]). In 2010, this represented a 13% relative increase, and in 2011, this represented a 23% relative increase. The post-HSS change in monthly rate of high-risk pregnancies referred increased slightly in intervention compared to control HC (0.03/10,000, 95% CI: [-0.007, 0.06]). There was a small immediate post-HSS increase in outpatient visit rates in intervention compared to control HC (6.64/1,000, 95% CI: [-13.52, 26.81]). We failed to find strong evidence of post-HSS increases in outpatient visit rates or referral rates at health centers, which could be explained by small sample size and high baseline nation-wide health service coverage. However, our findings demonstrate that high quality routinely collected health facility data combined with ITS can be used for rigorous policy evaluation in resource-limited settings.
Castejón, Nacho; Cappelleri, Joseph C; Cuervo, Jesús; Lang, Kathryn; Mehta, Priyanka; Mokgokong, Ruth; Mamolo, Carla
2018-04-18
Health state (HS) utility values for patients with acute myeloid leukemia (AML), a hematological malignancy, are not available in the United Kingdom (UK). This study aims to develop clinically sound HSs for previously untreated patients with AML and to assign utility values based on preferences of the general UK population. This study was conducted in the UK and comprised 2 stages. During the first stage, AML HSs were drafted based on evidence from a literature review of AML clinical and health-related quality-of-life studies (published January 2000-June 2016) and patient-reported outcome measures previously used in this population. A panel of UK hematologists with AML experience validated the clinical relevance and accuracy of the HSs. During the second stage, validated HSs were valued in an elicitation survey with a representative UK population sample using the time trade-off (TTO) method. Descriptive statistics and bivariate tests were obtained and performed. A total of eight HSs were developed and clinically validated, including treatment with chemotherapy, consolidation therapy, transplant, graft-vs-host disease (GvHD), remission, relapse, refractory, and functionally cured. In total, 125 adults participated (mean age, 49.6 years [range, 18-87 years], 52.8% female). Mean (95% confidence interval [CI]) TTO preference values (n = 120), ranked from lowest (worst HS) to highest (best HS) were as follows: refractory - 0.11 (- 0.21 to - 0.01), relapse 0.10 (0.00-0.20), transplant 0.28 (0.20-0.37), treatment with chemotherapy 0.36 (0.28-0.43), GvHD 0.43 (0.36-0.50), consolidation 0.46 (0.40-0.53), remission 0.62 (0.57-0.67), and functionally cured 0.76 (0.72-0.79). Mean (95% CI) visual analog scale preference values followed the same rank order, ranging from 0.15 (0.13-0.17) for refractory to 0.71 (0.68-0.73) for functionally cured. To our knowledge, this is the first study to report utility values for AML from the UK societal perspective. Participants were able to distinguish differences in severity among AML HSs, and preference values were consistent with clinical perception of HS severity. HS preference values observed in this study may be useful in future evaluations of treatment benefit, including cost-effectiveness analyses and improved patient well-being.
Iyer, Hari S.; Hirschhorn, Lisa R.; Nisingizwe, Marie Paul; Kamanzi, Emmanuel; Drobac, Peter C.; Rwabukwisi, Felix C.; Law, Michael R.; Muhire, Andrew; Rusanganwa, Vincent; Basinga, Paulin
2017-01-01
Background Evaluations of health systems strengthening (HSS) interventions using observational data are rarely used for causal inference due to limited data availability. Routinely collected national data allow use of quasi-experimental designs such as interrupted time series (ITS). Rwanda has invested in a robust electronic health management information system (HMIS) that captures monthly healthcare utilization data. We used ITS to evaluate impact of an HSS intervention to improve primary health care facility readiness on health service utilization in two rural districts of Rwanda. Methods We used controlled ITS analysis to compare changes in healthcare utilization at health centers (HC) that received the intervention (n = 13) to propensity score matched non-intervention health centers in Rwanda (n = 86) from January 2008 to December 2012. HC support included infrastructure renovation, salary support, medical equipment, referral network strengthening, and clinical training. Baseline quarterly mean outpatient visit rates and population density were used to model propensity scores. The intervention began in May 2010 and was implemented over a twelve-month period. We used monthly healthcare utilization data from the national Rwandan HMIS to study changes in the (1) number of facility deliveries per 10,000 women, (2) number of referrals for high risk pregnancy per 100,000 women, and (3) the number of outpatient visits performed per 1,000 catchment population. Results PHIT HC experienced significantly higher monthly delivery rates post-HSS during the April-June season than comparison (3.19/10,000, 95% CI: [0.27, 6.10]). In 2010, this represented a 13% relative increase, and in 2011, this represented a 23% relative increase. The post-HSS change in monthly rate of high-risk pregnancies referred increased slightly in intervention compared to control HC (0.03/10,000, 95% CI: [-0.007, 0.06]). There was a small immediate post-HSS increase in outpatient visit rates in intervention compared to control HC (6.64/1,000, 95% CI: [-13.52, 26.81]). Conclusion We failed to find strong evidence of post-HSS increases in outpatient visit rates or referral rates at health centers, which could be explained by small sample size and high baseline nation-wide health service coverage. However, our findings demonstrate that high quality routinely collected health facility data combined with ITS can be used for rigorous policy evaluation in resource-limited settings. PMID:28763505
Mei, Shenghui; Wang, Jiaqing; Zhu, Leting; Chen, Ruiling; Li, Xingang; Chen, Kai; Chen, Guangqiang; Zhou, Jianxin; Wang, Qiang; Zhao, Zhigang
2017-08-01
Vancomycin (VCM) is clinically used in treating patients with postoperative intracranial infections. The cerebrospinal fluid (CSF) concentration of VCM varies greatly among patients. To guide the dosage regimens, monitoring of VCM in CSF is needed. However a method for analysis of VCM in human CSF is lacking. An ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) was developed and validated for analysis of VCM in human CSF, and the agreement of UPLC-MS/MS and chemiluminescence immunoassay (CLIA) in the analysis of CSF VCM was evaluated. The ion transitions were m/z 725.5 > 144.1 for VCM and m/z 455.2 > 308.2 for methotrexate (internal standard). The agreement between UPLC-MS/MS and CLIA was evaluated by Bland-Altman plot in 179 samples. The calibration range of the UPLC-MS/MS method was 1-400 mg/L. The inaccuracy and imprecision were -0.69-10.80% and <4.95%. The internal standard normalized recovery and matrix factor were 86.14-99.31 and 85.84-92.07%, respectively. The measurements of CLIA and UPLC-MS/MS were strongly correlated (r > 0.98). The 95% limit of agreement of the ratio of CLIA to UPLC-MS/MS was 61.66-107.40%. Further studies are warranted to confirm the results. Copyright © 2017 John Wiley & Sons, Ltd.
Gaming science innovations to integrate health systems science into medical education and practice
White, Earla J; Lewis, Joy H; McCoy, Lise
2018-01-01
Health systems science (HSS) is an emerging discipline addressing multiple, complex, interdependent variables that affect providers’ abilities to deliver patient care and influence population health. New perspectives and innovations are required as physician leaders and medical educators strive to accelerate changes in medical education and practice to meet the needs of evolving populations and systems. The purpose of this paper is to introduce gaming science as a lens to magnify HSS integration opportunities in the scope of medical education and practice. Evidence supports gaming science innovations as effective teaching and learning tools to promote learner engagement in scientific and systems thinking for decision making in complex scenarios. Valuable insights and lessons gained through the history of war games have resulted in strategic thinking to minimize risk and save lives. In health care, where decisions can affect patient and population outcomes, gaming science innovations have the potential to provide safe learning environments to practice crucial decision-making skills. Research of gaming science limitations, gaps, and strategies to maximize innovations to further advance HSS in medical education and practice is required. Gaming science holds promise to equip health care teams with HSS knowledge and skills required for transformative practice. The ultimate goals are to empower providers to work in complex systems to improve patient and population health outcomes and experiences, and to reduce costs and improve care team well-being.
Stress-strain relationship of high-strength steel (HSS) reinforcing bars
NASA Astrophysics Data System (ADS)
Anggraini, Retno; Tavio, Raka, I. Gede Putu; Agustiar
2018-05-01
The introduction of High-Strength Steel (HSS) reinforcing bars in reinforced concrete members has gained much attention in recent years and led to many advantages such as construction timesaving. It is also more economical since it can reduce the amount of reinforcing steel bars used in concrete members which in turn alleviates the congestion of reinforcement. Up to present, the building codes, e.g. American Concrete Institute (ACI) 318M-14 and Standard National Indonesia (SNI) 2847:2013, still restrict the use of higher-strength steel reinforcing bars for concrete design up to Grade 420 MPa due to the possible suspected brittle behavior of concrete members. This paper evaluates the characteristics of stress-strain relationships of HSS bars if they are comparable to the characteristics of those of Grade 420 MPa. To achieve the objective of the study, a series of steel bars from various grades (420, 550, 650, and 700 MPa) was selected. Tensile tests of these steel samples were conducted under displacement-controlled mode to capture the complete stress-strain curves and particularly the post-yield response of the steel bars. The results indicate that all the steel bars tested had the actual yield strengths greater than the corresponding specified values. The stress-strain curves of HSS reinforcing bars (Grade 550, 650, and 700 MPa) performed slightly different characteristics with those of Grade 420 MPa.
Gaming science innovations to integrate health systems science into medical education and practice.
White, Earla J; Lewis, Joy H; McCoy, Lise
2018-01-01
Health systems science (HSS) is an emerging discipline addressing multiple, complex, interdependent variables that affect providers' abilities to deliver patient care and influence population health. New perspectives and innovations are required as physician leaders and medical educators strive to accelerate changes in medical education and practice to meet the needs of evolving populations and systems. The purpose of this paper is to introduce gaming science as a lens to magnify HSS integration opportunities in the scope of medical education and practice. Evidence supports gaming science innovations as effective teaching and learning tools to promote learner engagement in scientific and systems thinking for decision making in complex scenarios. Valuable insights and lessons gained through the history of war games have resulted in strategic thinking to minimize risk and save lives. In health care, where decisions can affect patient and population outcomes, gaming science innovations have the potential to provide safe learning environments to practice crucial decision-making skills. Research of gaming science limitations, gaps, and strategies to maximize innovations to further advance HSS in medical education and practice is required. Gaming science holds promise to equip health care teams with HSS knowledge and skills required for transformative practice. The ultimate goals are to empower providers to work in complex systems to improve patient and population health outcomes and experiences, and to reduce costs and improve care team well-being.
Chen, Jinyao; Yang, Feng; Kang, Jian; Cao, Ya; Xiang, Ming
2018-01-01
In this study, polyamide-aluminum foil-polypropylene (PA-Al-PP) composite films with different orientation status of the PP layer were prepared, and their morphology, tensile, peeling and heat seal behavior were studied. The comparative study of tensile and fracture behaviors of single-layer film of PA, Al and PP, as well as the composite films of PA-Al, PP-Al and PA-Al-PP revealed that in PA-Al-PP composite film, the PA layer with the highest tensile strength can share the tensile stress from the Al layer during stretching, while the PP layer with the lowest tensile strength can prevent further development of the small cracks on boundary of the Al layer during stretching. Moreover, the study of heat seal behavior suggested that both the orientation status and the heat seal conditions were important factors in determining the heat seal strength (HSS) and failure behavior of the sample. Four failure types were observed, and a clear correspondence between HSS and failure types was found. The results also elucidated that for the composite film, only in the cases where the tensile stress was efficiently released by each layer during HSS measurement could the composite film exhibit desired high HSS that was even higher than its tensile strength. PMID:29337881
Shin, Jung-Youn; Jeong, Jee-Heon; Han, Jin; Bhang, Suk Ho; Jeong, Gun-Jae; Haque, Muhammad R.; Al-Hilal, Taslim A.; Noh, Myungkyung
2015-01-01
Although islet transplantation has been suggested as an alternative therapy for type 1 diabetes, there are efficiency concerns that are attributed to poor engraftment of transplanted islets. Hypoxic condition and delayed vasculogenesis induce necrosis and apoptosis of the transplanted islets. To overcome these limitations in islet transplantation, heterospheroids (HSs), which consist of rat islet cells (ICs) and human bone marrow-derived mesenchymal stem cells (hMSCs), were transplanted to the kidney and liver. The HSs cultured under the hypoxic condition system exhibited a significant increase in antiapoptotic gene expression in ICs. hMSCs in the HSs secreted angiogenic and antiapoptotic proteins. With the HS system, ICs and hMSCs were successfully located in the same area of the liver after transplantation of HSs through the portal vein, whereas the transplantation of islets and the dissociated hMSCs did not result in localization of transplanted ICs and hMSCs in the same area. HS transplantation resulted in an increase in angiogenesis at the transplantation area and a decrease in the apoptosis of transplanted ICs after transplantation into the kidney subcapsule compared with transplantation of islet cell clusters (ICCs). Insulin production levels of ICs were higher in the HS transplantation group compared with the ICC transplantation group. The HS system may be a more efficient transplantation method than the conventional methods for the treatment of type 1 diabetes. PMID:25344077
Process depending morphology and resulting physical properties of TPU
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frick, Achim, E-mail: achim.frick@hs-aalen.de; Spadaro, Marcel, E-mail: marcel.spadaro@hs-aalen.de
2015-12-17
Thermoplastic polyurethane (TPU) is a rubber like material with outstanding properties, e.g. for seal applications. TPU basically provides high strength, low frictional behavior and excellent wear resistance. Though, due to segmented structure of TPU, which is composed of hard segments (HSs) and soft segments (SSs), physical properties depend strongly on the morphological arrangement of the phase separated HSs at a certain ratio of HSs to SSs. It is obvious that the TPU deforms differently depending on its bulk morphology. Basically, the morphology can either consist of HSs segregated into small domains, which are well dispersed in the SS matrix ormore » of few strongly phase separated large size HS domains embedded in the SS matrix. The morphology development is hardly ruled by the melt processing conditions of the TPU. Depending on the morphology, TPU provides quite different physical properties with respect to strength, deformation behavior, thermal stability, creep resistance and tribological performance. The paper deals with the influence of important melt processing parameters, such as temperature, pressure and shear conditions, on the resulting physical properties tested by tensile and relaxation experiments. Furthermore the morphology is studied employing differential scanning calorimeter (DSC), transmission light microscopy (TLM), scanning electron beam microscopy (SEM) and transmission electron beam microscopy (TEM) investigations. Correlations between processing conditions and resulting TPU material properties are elaborated. Flow and shear simulations contribute to the understanding of thermal and flow induced morphology development.« less
Zhu, Hongbin; Wang, Chunyan; Qi, Yao; Song, Fengrui; Liu, Zhiqiang; Liu, Shuying
2013-01-15
A fingerprinting approach was developed by means of UPLC-ESI/MS(n) (ultra-performance liquid chromatography-electrospray ionization/mass spectrometry) for the quality control of processed Radix Aconiti, a widely used toxic traditional herbal medicine. The present fingerprinting approach was based on the two processing methods recorded in Chinese Pharmacopoeia for the purpose of reducing the toxicity and ensuring the clinical therapeutic efficacy. Similarity evaluation, hierarchical cluster analysis and principal component analysis were performed to evaluate the similarity and variation of the samples. The results showed that the well processed, unqualified processed and the raw Radix Aconiti could be clustered reasonably corresponding to the contents of their constituents. The loading plot shows that the main chemical markers having the most influence on the discrimination amongst the qualified and unqualified samples were mainly some monoester diterpenoid aconitines and diester diterpenoid aconitines. Finally, the UPLC-UV and UPLC-ESI/MS(n) characteristic fingerprints were established according to the well processed and purchased qualified samples. At the same time, a complementary quantification method of six Aconitine-type alkaloids was developed using UPLC-UV and UPLC-ESI/MS. The average recovery of the monoester diterpenoid aconitines was 95.4-99.1% and the average recovery of the diester diterpenoid aconitines was 103-112%. The proposed combined quantification method by UPLC-UV and UPLC-ESI/MS allows the samples analyzed in a wide concentration range. Therefore, the established fingerprinting approach in combination with chemometric analysis provides a flexible and reliable method for quality assessment of toxic herbal medicine. Copyright © 2012 Elsevier B.V. All rights reserved.
Garchitorena, Andres; Miller, Ann C; Cordier, Laura F; Rabeza, Victor R; Randriamanambintsoa, Marius; Razanadrakato, Hery-Tiana R; Hall, Lara; Gikic, Djordje; Haruna, Justin; McCarty, Meg; Randrianambinina, Andriamihaja; Thomson, Dana R; Atwood, Sidney; Rich, Michael L; Murray, Megan B; Ratsirarson, Josea; Ouenzar, Mohammed Ali; Bonds, Matthew H
2018-01-01
The Sustainable Development Goals framed an unprecedented commitment to achieve global convergence in child and maternal mortality rates through 2030. To meet those targets, essential health services must be scaled via integration with strengthened health systems. This is especially urgent in Madagascar, the country with the lowest level of financing for health in the world. Here, we present an interim evaluation of the first 2 years of a district-level health system strengthening (HSS) initiative in rural Madagascar, using estimates of intervention coverage and mortality rates from a district-wide longitudinal cohort. We carried out a district representative household survey at baseline of the HSS intervention in over 1500 households in Ifanadiana district. The first follow-up was after the first 2 years of the initiative. For each survey, we estimated maternal, newborn and child health (MNCH) coverage, healthcare inequalities and child mortality rates both in the initial intervention catchment area and in the rest of the district. We evaluated changes between the two areas through difference-in-differences analyses. We estimated annual changes in health centre per capita utilisation from 2013 to 2016. The intervention was associated with 19.1% and 36.4% decreases in under-five and neonatal mortality, respectively, although these were not statistically significant. The composite coverage index (a summary measure of MNCH coverage) increased by 30.1%, with a notable 63% increase in deliveries in health facilities. Improvements in coverage were substantially larger in the HSS catchment area and led to an overall reduction in healthcare inequalities. Health centre utilisation rates in the catchment tripled for most types of care during the study period. At the earliest stages of an HSS intervention, the rapid improvements observed for Ifanadiana add to preliminary evidence supporting the untapped and poorly understood potential of integrated HSS interventions on population health.
Eskelinen, Matti; Korhonen, Riika; Selander, Tuomas; Ollonen, Paula
2015-02-01
The relation between hopelessness/helplessness versus the Beck Depression Inventory (BDI) in healthy study subjects (HSS) and in patients with benign breast disease (BBD) and breast cancer (BC) has not been compared in a prospective study before. We, therefore, investigated hopelessness and helplessness versus the BDI in 115 patients. In the Kuopio Breast Cancer Study, 115 women with breast symptoms were evaluated for hopelessness and helplessness versus the BDI before any diagnostic procedures were carried out. In the self-rating score (SRS), the hopelessness and the helplessness versus the BDI were highly significantly positively correlated in the HSS, BBD and BC groups. In the SRS, the weighted kappa values for hopelessness and helplessness versus the BDI in the HSS, BBD and BC groups were also statistically significant. There was also a significant positive correlation in the examiner-rating score (ERS) in the hopelessness versus the BDI in the BBD and BC groups and in the ERS in helplessness versus the BDI in the HSS and BBD groups. The unweighted kappa values in the ERS for hopelessness versus the BDI in the HSS and BBD groups were statistically highly significant and the unweighted kappa values in the ERS for helplessness versus the BDI in the BBD and BC groups were statistically significant. The results of this study support a powerful link between hopelessness and helplessness versus BDI in the self-rating and examiner-rating. This finding is of clinical importance since, in the breast cancer diagnostic unit, the patients with hopelessness/helplessness characteristics and high BDI score might be associated with a difficulty and delay in reaching BC diagnosis. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.
Tyrosine Phosphorylation of Botulinum Neurotoxin Protease Domains
2012-06-01
trifluoroacetic acid; Tm: melting temperature; TMB, 3,3′,5,5′-tetramethylbenzidine; UPLC , ultra performance liquid chromatography; VAMP, vesicle...activity determination by UPLC . Alternately, in large-scale preparations, phosphoryla- tion reaction was stopped by removing the Src with sepharose beads...peptides. ENZYMATIC ACTIVITY ASSAYS Activity assays were based on UPLC separation and measurement of the cleaved products from a 17-residue SNAP-25
Safety of the HyperSound® Audio System in Subjects with Normal Hearing.
Mehta, Ritvik P; Mattson, Sara L; Kappus, Brian A; Seitzman, Robin L
2015-06-11
The objective of the study was to assess the safety of the HyperSound® Audio System (HSS), a novel audio system using ultrasound technology, in normal hearing subjects under normal use conditions; we considered pre-exposure and post-exposure test design. We investigated primary and secondary outcome measures: i) temporary threshold shift (TTS), defined as >10 dB shift in pure tone air conduction thresholds and/or a decrement in distortion product otoacoustic emissions (DPOAEs) >10 dB at two or more frequencies; ii) presence of new-onset otologic symptoms after exposure. Twenty adult subjects with normal hearing underwent a pre-exposure assessment (pure tone air conduction audiometry, tympanometry, DPOAEs and otologic symptoms questionnaire) followed by exposure to a 2-h movie with sound delivered through the HSS emitter followed by a post-exposure assessment. No TTS or new-onset otological symptoms were identified. HSS demonstrates excellent safety in normal hearing subjects under normal use conditions.
Safety of the HyperSound® Audio System in Subjects with Normal Hearing
Mattson, Sara L.; Kappus, Brian A.; Seitzman, Robin L.
2015-01-01
The objective of the study was to assess the safety of the HyperSound® Audio System (HSS), a novel audio system using ultrasound technology, in normal hearing subjects under normal use conditions; we considered pre-exposure and post-exposure test design. We investigated primary and secondary outcome measures: i) temporary threshold shift (TTS), defined as >10 dB shift in pure tone air conduction thresholds and/or a decrement in distortion product otoacoustic emissions (DPOAEs) >10 dB at two or more frequencies; ii) presence of new-onset otologic symptoms after exposure. Twenty adult subjects with normal hearing underwent a pre-exposure assessment (pure tone air conduction audiometry, tympanometry, DPOAEs and otologic symptoms questionnaire) followed by exposure to a 2-h movie with sound delivered through the HSS emitter followed by a post-exposure assessment. No TTS or new-onset otological symptoms were identified. HSS demonstrates excellent safety in normal hearing subjects under normal use conditions. PMID:26779330
Solar wind iron abundance variations at solar wind speeds up to 600 km s sup -1, 1972 to 1976
NASA Technical Reports Server (NTRS)
Mitchell, D. G.; Roelof, E. C.; Bame, S. J.
1982-01-01
The Fe/H ratios in the peaks of high speed streams (HSS) were analyzed during the decline of Solar Cycle 20 and the following minimum (October 1972 to December 1976). The response of the 50 to 200 keV ion channel of the APL/JHU energetic particle experiment (EPE) on IMP-7 and 8 was utilized to solar wind iron ions at high solar wind speeds (V or = 600 km/sec). Fe measurements with solar wind H and He parameters were compared from the Los Alamos National Laboratory (LANL) instruments on the same spacecraft. In general, the Fe distribution parameters (bulk velocity, flow direction, temperature) are found to be similar to the LANL He parameters. Although the average Fe/H ration in many steady HSS peaks agrees within observational uncertainties with the nominal coronal ratio of 4.7 x 0.00001, abundance variations of a factor of up to 6 are obtained across a given coronal-hole associated HSS.
Major Geomagnetic Storms in Solar Cycle 24
NASA Astrophysics Data System (ADS)
Zheng, Y.
2013-12-01
Solar Cycle 24 has produced 11 major geomagnetic storms (where Dstmin < -100 nT) with three in 2011, six in 2012 and two in 2013 (as of 7 August 2013). Detailed analysis of each event will be given in terms of its solar driver(s): CME, coronal hole high speed solar wind stream (HSS), multiple CMEs or interactions between CME and HSS. While some of these storms are associated with a fast and wide CME, the few cases involving slow or common CMEs and interactions with HSS are particularly interesting. These events pose great challenges for accurate space weather forecasting, since operationally the slower or average CMEs tend to receive less attention and are sometimes overlooked altogether. The characteristics of such challenging, not-so-fast yet geoeffective CME events (such as their coronal signatures and interactions with surrounding solar wind structure(s), etc) will be examined in detail, with the goal of extracting common and telltale features, if any, of these CMEs that distinguish them from CMEs in a similar category.
Lang, Lang; Meng, Zhaorui; Sun, Lan; Xiao, Wei; Zhao, Longshan; Xiong, Zhili
2018-02-01
Guizhi Fuling capsule (GFC), developed from the traditional Chinese prescription of Guizhi Fuling Wan, has been commonly used for the treatment of primary dysmenorrhea (PD). However, the intervention effective mechanism in vivo has not been well elucidated. In this study, an integrated plasma metabonomic strategy based on RP-UPLC-MS coupled with HILIC-UPLC-MS technique has been developed to investigate the global therapeutic effects and intervention mechanisms of GFC on dysmenorrhea rats induced by oxytocin. The 20 potential biomarkers were identified and primarily related to sphingolipid metabolism, steroid hormone biosynthesis, glycerophospholipid metabolism, amino acid metabolism, lipid metabolism and energy metabolism. The results showed that the GFC has therapeutic effects on rats with dysmenorrhea via the regulation of multiple metabolic pathways. Some new potential biomarkers associated with primary dysmenorrhea such as phenylalanine, tryptophan, taurine, carnitine, betaine, creatine and creatinine have been discovered in this study for the first time. This study provides a metabonomic platform based on RP-UPLC-MS complementary to HILIC-UPLC-MS technique to investigate both nonpolar and polar compounds, so as to get a more comprehensive metabolite information to yield insight into the pathophysiology of PD and assessing the efficacy of GFC on PD rats. Copyright © 2017 John Wiley & Sons, Ltd.
Chen, Chu; Xue, Ying; Li, Qing-Miao; Wu, Yan; Liang, Jian; Qing, Lin-Sen
2018-04-01
Amorfrutins with a 2-hydroxybenzoic acid core structure are promising natural PPARγ agonists with potent antidiabetic activity. Owing to the complex matrix and low concentration in botanical material, the identification of unknown amorfrutins remains a challenge. In the present study, a combined application of UPLC-Q-TOF-MS and UPLC-QqQ-MS was developed to discover unknown amorfrutins from fruits of Amorpha fruticosa. First, reference compounds of amorfrutin A (AA), amorfrutin B (AB), and 2-carboxy-3,5-dihydroxy-4-geranylbibenzyl (AC) were analyzed using UPLC-Q-TOF-MS to reveal the characteristic fragment ions and the possible neutral loss. Second, the extract of A. fruticosa was separated and screened by UPLC-QqQ-MS using neutral loss scan to find out suspect compounds associated with the specified neutral fragment Δm/z 44. Third, the extract was re-analyzed by UPLC-Q-TOF-MS to obtain the exact mass of quasi-molecular ion and fragment ions of each suspect compound, and to subsequently calculate their corresponding molecular formulas. Finally, according to the molecular formula of suspect compound and its fragment ions and comparing with literature data, structure elucidation of four unidentified amorfrutins was achieved. The results indicated that the combination of QqQ-MS neutral loss scan and Q-TOF-MS molecular formula calculation was proven to be a powerful tool for unknown natural product identification, and this strategy provides an effective solution to discover natural products or metabolites of trace content. Graphical Abstract ᅟ.
Zhou, Fei; Zhao, Yajing; Peng, Jiyu; Jiang, Yirong; Li, Maiquan; Jiang, Yuan; Lu, Baiyi
2017-07-01
Osmanthus fragrans flowers are used as folk medicine and additives for teas, beverages and foods. The metabolites of O. fragrans flowers from different geographical origins were inconsistent in some extent. Chromatography and mass spectrometry combined with multivariable analysis methods provides an approach for discriminating the origin of O. fragrans flowers. To discriminate the Osmanthus fragrans var. thunbergii flowers from different origins with the identified metabolites. GC-MS and UPLC-PDA were conducted to analyse the metabolites in O. fragrans var. thunbergii flowers (in total 150 samples). Principal component analysis (PCA), soft independent modelling of class analogy analysis (SIMCA) and random forest (RF) analysis were applied to group the GC-MS and UPLC-PDA data. GC-MS identified 32 compounds common to all samples while UPLC-PDA/QTOF-MS identified 16 common compounds. PCA of the UPLC-PDA data generated a better clustering than PCA of the GC-MS data. Ten metabolites (six from GC-MS and four from UPLC-PDA) were selected as effective compounds for discrimination by PCA loadings. SIMCA and RF analysis were used to build classification models, and the RF model, based on the four effective compounds (caffeic acid derivative, acteoside, ligustroside and compound 15), yielded better results with the classification rate of 100% in the calibration set and 97.8% in the prediction set. GC-MS and UPLC-PDA combined with multivariable analysis methods can discriminate the origin of Osmanthus fragrans var. thunbergii flowers. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Integration of electrochemistry with ultra-performance liquid chromatography/mass spectrometry.
Cai, Yi; Zheng, Qiuling; Liu, Yong; Helmy, Roy; Loo, Joseph A; Chen, Hao
2015-01-01
This study presents the development of ultra-performance liquid chromatography (UPLC) mass spectrometry (MS) combined with electrochemistry (EC) for the first time and its application for the structural analysis of proteins/peptides that contain disulfide bonds. In our approach, a protein/peptide mixture sample undergoes a fast UPLC separation and subsequent electrochemical reduction in an electrochemical flow cell followed by online MS and tandem mass spectrometry (MS/MS) analyses. The electrochemical cell is coupled to the mass spectrometer using our recently developed desorption electrospray ionization (DESI) interface. Using this UPLC/EC/DESI-MS method, peptides that contain disulfide bonds can be differentiated from those without disulfide bonds, as the former are electroactive and reducible. MS/MS analysis of the disulfide-reduced peptide ions provides increased information on the sequence and disulfide-linkage pattern. In a reactive DESI- MS detection experiment in which a supercharging reagent was used to dope the DESI spray solvent, increased charging was obtained for the UPLC-separated proteins. Strikingly, upon online electrolytic reduction, supercharged proteins (e.g., α-lactalbumin) showed even higher charging, which will be useful in top- down protein structure MS analysis as increased charges are known to promote protein ion dissociation. Also, the separation speed and sensitivity are enhanced by approximately 1(~)2 orders of magnitude by using UPLC for the liquid chromatography (LC)/EC/MS platform, in comparison to the previously used high- performance liquid chromatography (HPLC). This UPLC/EC/DESI-MS method combines the power of fast UPLC separation, fast electrochemical conversion, and online MS structural analysis for a potentially valuable tool for proteomics research and bioanalysis.
NASA Astrophysics Data System (ADS)
Chen, Chu; Xue, Ying; Li, Qing-Miao; Wu, Yan; Liang, Jian; Qing, Lin-Sen
2018-02-01
Amorfrutins with a 2-hydroxybenzoic acid core structure are promising natural PPARγ agonists with potent antidiabetic activity. Owing to the complex matrix and low concentration in botanical material, the identification of unknown amorfrutins remains a challenge. In the present study, a combined application of UPLC-Q-TOF-MS and UPLC-QqQ-MS was developed to discover unknown amorfrutins from fruits of Amorpha fruticosa. First, reference compounds of amorfrutin A (AA), amorfrutin B (AB), and 2-carboxy-3,5-dihydroxy-4-geranylbibenzyl (AC) were analyzed using UPLC-Q-TOF-MS to reveal the characteristic fragment ions and the possible neutral loss. Second, the extract of A. fruticosa was separated and screened by UPLC-QqQ-MS using neutral loss scan to find out suspect compounds associated with the specified neutral fragment Δm/z 44. Third, the extract was re-analyzed by UPLC-Q-TOF-MS to obtain the exact mass of quasi-molecular ion and fragment ions of each suspect compound, and to subsequently calculate their corresponding molecular formulas. Finally, according to the molecular formula of suspect compound and its fragment ions and comparing with literature data, structure elucidation of four unidentified amorfrutins was achieved. The results indicated that the combination of QqQ-MS neutral loss scan and Q-TOF-MS molecular formula calculation was proven to be a powerful tool for unknown natural product identification, and this strategy provides an effective solution to discover natural products or metabolites of trace content.
Yu, Kate; Little, David; Plumb, Rob; Smith, Brian
2006-01-01
A quantitative Ultra Performance liquid chromatography/tandem mass spectrometry (UPL/MS/MS) protocol was developed for a five-compound mixture in rat plasma. A similar high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) quantification protocol was developed for comparison purposes. Among the five test compounds, three preferred positive electrospray ionization (ESI) and two preferred negative ESI. As a result, both UPLC/MS/MS and HPLC/MS/MS analyses were performed by having the mass spectrometer collecting ESI multiple reaction monitoring (MRM) data in both positive and negative ion modes during a single injection. Peak widths for most standards were 4.8 s for the HPLC analysis and 2.4 s for the UPLC analysis. There were 17 to 20 data points obtained for each of the LC peaks. Compared with the HPLC/MS/MS method, the UPLC/MS/MS method offered 3-fold decrease in retention time, up to 10-fold increase in detected peak height, with 2-fold decrease in peak width. Limits of quantification (LOQs) for both HPLC and UPLC methods were evaluated. For UPLC/MS/MS analysis, a linear range up to four orders of magnitude was obtained with r2 values ranging from 0.991 to 0.998. The LOQs for the five analytes ranged from 0.08 to 9.85 ng/mL. Three levels of quality control (QC) samples were analyzed. For the UPLC/MS/MS protocol, the percent relative standard deviation (RSD%) for low QC (2 ng/mL) ranged from 3.42 to 8.67% (N = 18). The carryover of the UPLC/MS/MS protocol was negligible and the robustness of the UPLC/MS/MS system was evaluated with up to 963 QC injections. Copyright 2006 John Wiley & Sons, Ltd.
Wang, Jian; Leung, Daniel
2012-08-01
This paper discusses the analytical challenges to develop a generic extraction procedure to analyze or screen multi-class veterinary drugs in milk and honey using ultra-high pressure liquid chromatography quadrupole time-of-flight mass spectrometry (UHPLC QqTOF MS). The veterinary drugs in this study included aminoglycosides, endectocides, fluoroquinolones, ionophores, β-lactams or penicillins, macrolides, NSAIDs, phenicols, sulfonamides and tetracyclines. Veterinary drugs were extracted using a QuEChERS (quick, easy, cheap, effective, rugged, and safe) method, which entailed the use of acetonitrile containing 1% acetic acid, sodium acetate, ethylenediaminetetra acetic acid disodium (EDTA) and magnesium sulfate, and no clean-up was performed. Chromatographic separation was achieved on a reversed-phase Acquity UPLC BEH C(18) , 100 × 2.1 mm, 1.7 µm column with 0.1% formic acid and 10 mM ammonium formate in water, and acetonitrile as mobile phases. Due to poor chromatographic retention, aminoglycosides were first dropped from the list, and because of poor extractability, β-lactams and tetracyclines were also excluded from the method. The method was able to quantify 31 or screen up to 54 drugs (unbound) in honey, and to quantify 34 or screen up to 59 drugs in milk. UHPLC QqTOF data were acquired in TOF MS full-scan mode that allowed both quantification and confirmation of veterinary drugs and identification of their degradation products in samples. The method could achieve detection limits as low as 1 µg/kg with analytical range from 1 to 100 µg/kg. The developed method was intended to be used for screening of as many analytes as possible in one single analysis, or unequivocal confirmation of positive findings and degradation product identification based on accurate mass measurement and isotopic patterns. © Her Majesty the Queen in Right of Canada 2012. Reproduced with the permission of the Minister of Agriculture.
Muharem, Muhteber; Yan, Hua; Xu, Shan; Feng, Nan; Hao, Jie; Zhu, Chenqi; Guo, Shuang; Zhang, Zhaohui; Han, Nanyin
2015-11-01
An ultra high liquid chromatography-Q Exactive orbitrap mass spectrometry multi-residue method has been developed for the determination of six anticoccidials residues (dinitlmide, nicarbazin, diclazuril, toltrazuril, monensin and salinomycin) in chicken tissue. Sample preparation was based on QuEChERS method, using 1% (v/v) trichloroacetic acid/acetonitrile aqueous solution (3:7, v/v) as the extraction solvent and salting-out with sodium chloride followed by clean-up with 50 mg/mL primary secondary amine (PSA) +50 mg/mL neutral alumina (Alumina-N) dispersive solid phase extraction (DSPE). The separation of the compounds in liquid chromatography was carried out using a Waters Acquity UPLC BEH C8 column (100 mm x 2.1 mm, 1.7 μm) with mobile phases consisting of methanol-5 mmol/L ammonium acetate aqueous solution in gradient elution. The Q Exactive orbitrap mass spectrometric detection was carried out with positive and negative electrospray ionization simultaneously. The results showed the linear ranges of the six target compounds were as follows: dinitolmide, 1.0-30.0 μg/L; nicarbazin, 0.2-6.0 μg/L; diclazuril and toltrazuril, 2.0-60.0 [μg/L; monensin and salinomycin, 4.0-120.0 μg/L. The external standard method was used for quantification. The spiked recoveries at three levels for the six anticoccidials ranged from 67.7% to 126.8%. The relative standard deviations (RSDs) were ≤ 10.4%. The limits of quantification (LOQs) were as follows: dinitolmide, 2.50 μg/kg; nicarbazin, 0.50 μg/kg; diclazuril and toltrazuril, 5.00 μg/kg; monensin and salinomycin, 20.00 μg/kg. The developed method is easy of operation and of high sensitivity. It can meet the requirements of daily inspection.
Van Poucke, Christof; Van Vossel, Evy; Van Peteghem, Carlos
2008-08-01
For over a decade there has been an intensive debate on the possible natural origin of boldenone (androst-1,4-diene-17beta-ol-3-one, 17beta-boldenone) in calf urine and several alternative markers to discriminate between endogenously formed boldenone and exogenously administered boldenone have been suggested. The currently approved method for proving illegal administration of beta-boldenone(ester) is the detection of beta-boldenone conjugates. In the presented method the sulphate, glucuronide and free fractions are separated from each other during cleanup on a SAX column to be able to determine the conjugated status of the boldenone metabolites. The sulphate and glucuronide fractions are submitted to hydrolysis and all three fractions are further cleaned up on a combination of C18/NH2 solid-phase extraction (SPE) columns. Chromatographic separation of the boldenone metabolites was achieved with a Waters Acquity UPLC instrument using a Sapphire C18 (1.7 microm; 2x50 mm) column within 5 min. Detection of the analytes was achieved by electrospray ionisation tandem mass spectrometry. The decision limits of this method, validated according to Commission Decision 2002/657/EC, were 0.08 ng mL(-1) for androsta-1,4-diene-3,17-dione, 0.13 ng mL(-1) for androst-4-ene-3,17-dione, 0.11 ng mL(-1) for 17alpha-boldenone, 0.07 ng mL(-1) for 17beta-boldenone, 0.24 ng mL(-1) for 5beta-androst-1-en-17beta-ol-3-one and 0.58 ng mL(-1) for 6beta-hydroxy-17beta-boldenone. Because of the fractionation approach used in this method there is no need for conjugated reference standards which often are not available. The disadvantage of needing three analytical runs to determine the conjugated status of each of the metabolites was overcome by using fast chromatography. Copyright (c) 2008 John Wiley & Sons, Ltd.
Yang, Jiwon; Shin, Chang-Yup; Chung, Jin Ho
2018-01-01
BACKGROUND/OBJECTIVES Ultraviolet radiation (UV) is a major cause of skin photoaging. Previous studies reported that ethanol extract (PET) of Prunus persica (L.) Batsch flowers (PPF, peach flowers) and its subfractions, particularly the ethylacetate (PEA) and n-butanol extracts (PBT), have potent antioxidant activity and attenuate the UV-induced matrix metalloproteinase (MMP) expression in human skin cells. In this study, we investigated the protective activity of PPF extract against UV-induced photoaging in a mouse model. MATERIALS/METHODS Hairless mice were treated with PET or a mixture of PEA and PBT either topically or orally along with UV irradiation. Histological changes and biochemical alterations of mouse skin were examined. Major phenolic compounds in PPF extract were analyzed using an ACQUITY UPLC system. RESULTS The overall effects of topical and oral treatments with PPF extract on the UV-induced skin responses exhibited similar patterns. In both experiments, the mixture of PEA and PBT significantly inhibited the UV-induced skin and epidermal thickening, while PET inhibited only the UV-induced epidermal thickening. Treatment of PET or the mixture of PEA and PBT significantly inhibited the UV-induced MMP-13 expression, but not typeⅠ collagen expression. Topical treatment of the mixture of PEA and PBT with UV irradiation significantly elevated catalase, superoxide dismutase (SOD) and glutathione-peroxidase (GPx) activities in the skin compared to those in the UV irradiated control group, while oral treatment of the mixture of PEA and PBT or PET elevated only catalase and SOD activities, but not GPx. Thirteen phytochemical compounds including 4-O-caffeoylquinic acid, cimicifugic acid E and B, quercetin-3-O-rhamnoside and kaempferol glycoside derivatives were identified in the PPF extract. CONCLUSIONS These results demonstrate that treatment with PET or the mixture of PEA and PBT, both topically or orally, attenuates UV-induced photoaging via the cooperative interactions of phenolic components having anti-oxidative and collagen-protective activities. PMID:29399294
Heaney, Liam M; Jones, Donald J L; Mbasu, Richard J; Ng, Leong L; Suzuki, Toru
2016-01-01
Trimethylamine N-oxide (TMAO) has attracted interest as circulating levels have reported prognostic value in patients with cardiovascular conditions, such as heart failure. With continual advances in accurate mass measurements, robust methods that can employ the capabilities of time of flight mass spectrometers would offer additional utility in the analysis of complex clinical samples. A Waters Acquity UPLC was coupled to a Waters Synapt G2-S high-resolution mass spectrometer. TMAO was measured in plasma by stable-isotope dilution-hydrophilic interaction liquid chromatography-time of flight mass spectrometry with multiple reaction monitoring (LC-ToF-MRM). Two transitions were monitored: m/z 76.1 to 58.066/59.073 and m/z 85.1 to 66.116/68.130. The method was assessed for linearity, lower limits of detection and quantitation, and reproducibility. A selected cohort of patients with systolic heart failure (SHF; n = 43) and healthy controls (n = 42) were measured to verify the assay is suitable for the analysis of clinical samples. Quantitative analysis of TMAO using LC-ToF-MRM enabled linearity to be established between 0.1 and 75 μmol/L, with a lower limit of detection of 0.05 μmol/L. Relative standard deviations reported an inter-day variation of ≤20.8% and an intra-day variation of ≤11.4% with an intra-study quality control variation of 2.7%. Run times were 2.5 min. Clinical application of the method reported that TMAO in SHF was elevated compared to that of healthy controls (p < 0.0005). LC-ToF-MRM offers a highly selective method for accurate mass measurement of TMAO with rapid and reproducible results. Applicability of the method was shown in a selected cohort of patient samples.
Lemasson, Elise; Bertin, Sophie; Hennig, Philippe; Boiteux, Hélène; Lesellier, Eric; West, Caroline
2015-08-21
Impurity profiling of organic products that are synthesized as possible drug candidates requires complementary analytical methods to ensure that all impurities are identified. Supercritical fluid chromatography (SFC) is a very useful tool to achieve this objective, as an adequate selection of stationary phases can provide orthogonal separations so as to maximize the chances to see all impurities. In this series of papers, we have developed a method for achiral SFC-MS profiling of drug candidates, based on a selection of 160 analytes issued from Servier Research Laboratories. In the first part of this study, focusing on mobile phase selection, a gradient elution with carbon dioxide and methanol comprising 2% water and 20mM ammonium acetate proved to be the best in terms of chromatographic performance, while also providing good MS response [1]. The objective of this second part was the selection of an orthogonal set of ultra-high performance stationary phases, that was carried out in two steps. Firstly, a reduced set of analytes (20) was used to screen 23 columns. The columns selected were all 1.7-2.5μm fully porous or 2.6-2.7μm superficially porous particles, with a variety of stationary phase chemistries. Derringer desirability functions were used to rank the columns according to retention window, column efficiency evaluated with peak width of selected analytes, and the proportion of analytes successfully eluted with good peak shapes. The columns providing the worst performances were thus eliminated and a shorter selection of columns (11) was obtained. Secondly, based on 160 tested analytes, the 11 columns were ranked again. The retention data obtained on these columns were then compared to define a reduced set of the best columns providing the greatest orthogonality, to maximize the chances to see all impurities within a limited number of runs. Two high-performance columns were thus selected: ACQUITY UPC(2) HSS C18 SB and Nucleoshell HILIC. Copyright © 2015 Elsevier B.V. All rights reserved.
Pauk, Volodymyr; Pluháček, Tomáš; Havlíček, Vladimír; Lemr, Karel
2017-10-09
The ultra-high performance supercritical fluid chromatography-mass spectrometry (UHPSFC/MS) procedure for analysis of native monosaccharides was developed. Chromatographic conditions were investigated to separate a mixture of four hexoses, three pentoses, two deoxyhexoses and two uronic acids. Increasing water content in methanol modifier to 5% and formic acid to 4% improved peak shapes of neutral monosaccharides and allowed complete elution of highly polar uronic acids in a single run. An Acquity HSS C18SB column outperformed other three tested stationary phases (BEH (silica), BEH 2-ethylpyridine, CSH Fluoro-Phenyl) in terms of separation of isomers and analysis time (4.5 min). Limits of detection were in the range 0.01-0.12 ng μL -1 . Owing to separation of anomers, identification of critical pairs (arabinose-xylose and glucose-galactose) was possible. Feasibility of the new method was demonstrated on plant-derived polysaccharide binders. Samples of watercolor paints, painted paper and three plant gums widely encountered in painting media (Arabic, cherry and tragacanth) were decomposed prior the analysis by microwave-assisted hydrolysis at 40 bar initial pressure using 2 mol L -1 trifluoroacetic acid. Among tested temperatures, 120 °C ensured appropriate hydrolysis efficiency for different types of gum and avoided excessive degradation of labile monosaccharides. Procedure recovery tested on gum Arabic was 101% with an RSD below 8%. Aqueous hydrolysates containing monosaccharides in different ratios specific to each type of plant gum were diluted or analyzed directly. Filtration of samples before hydrolysis reduced interferences from a paper support and identification of gum Arabic in watercolor-painted paper samples was demonstrated. Successful identification of pure gum Arabic was confirmed for sample quantities as little as 1 μg. Two classification approaches were compared and principal component analysis was superior to analysis based on peak area ratios of monosaccharides. The proposed procedure using UHPSFC/MS represents an interesting alternative which can compete with other chromatographic methods in the field of saccharide analysis in terms of speed, sensitivity and simplicity of workflow. Copyright © 2017 Elsevier B.V. All rights reserved.
Alépée, N; Barroso, J; De Smedt, A; De Wever, B; Hibatallah, J; Klaric, M; Mewes, K R; Millet, M; Pfannenbecker, U; Tailhardat, M; Templier, M; McNamee, P
2015-06-01
A number of in vitro test methods using Reconstructed human Tissues (RhT) are regulatory accepted for evaluation of skin corrosion/irritation. In such methods, test chemical corrosion/irritation potential is determined by measuring tissue viability using the photometric MTT-reduction assay. A known limitation of this assay is possible interference of strongly coloured test chemicals with measurement of formazan by absorbance (OD). To address this, Cosmetics Europe evaluated use of HPLC/UPLC-spectrophotometry as an alternative formazan measurement system. Using the approach recommended by the FDA guidance for validation of bio-analytical methods, three independent laboratories established and qualified their HPLC/UPLC-spectrophotometry systems to reproducibly measure formazan from tissue extracts. Up to 26 chemicals were then tested in RhT test systems for eye/skin irritation and skin corrosion. Results support that: (1) HPLC/UPLC-spectrophotometry formazan measurement is highly reproducible; (2) formazan measurement by HPLC/UPLC-spectrophotometry and OD gave almost identical tissue viabilities for test chemicals not exhibiting colour interference nor direct MTT reduction; (3) independent of the test system used, HPLC/UPLC-spectrophotometry can measure formazan for strongly coloured test chemicals when this is not possible by absorbance only. It is therefore recommended that HPLC/UPLC-spectrophotometry to measure formazan be included in the procedures of in vitro RhT-based test methods, irrespective of the test system used and the toxicity endpoint evaluated to extend the applicability of these test methods to strongly coloured chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhou, Shujun; Cao, Jiliang; Qiu, Feng; Kong, Weijun; Yang, Shihai; Yang, Meihua
2013-01-01
Glycyrrhizae species are popular ingredients of herbal medicine in most traditional Chinese medicine prescriptions, and they mainly contain flavonoids and triterpene saponins. The contents of these bioactive compounds may vary in different batches and affect the therapeutic effects. Thus comprehensive quality control and monitoring of their herbal formulation are of paramount concern. To establish a rapid, effective pressurised liquid extraction (PLE) and ultra-performance liquid chromatography coupled with photodiode array (UPLC-PDA) method to evaluate the quality of Glycyrrhizae species. Radix Glycyrrhizae was extracted by PLE using 70% ethanol at 100°C for 15 min during three static extraction cycles. Separation was performed using an UPLC system to quantify five bioactive compounds, namely liquiritin apioside, liquiritin, liquiritigenin, glycyrrhizic acid and glycyrrhetinic acid, in 12 batches of samples of different origins in China. Furthermore, the samples were analysed using an ultra-performance liquid chromatography coupled with electrospray ionisation and time-of-flight mass spectrometry (UPLC/ESI-QTOF-MS) system to confirm the results. The calibration curves of all five analytes showed good linearity (R(2) > 0.9997). Accuracy, precision and repeatability were all within required limits. The mean recoveries measured at the three concentrations were higher than 93.7% with RSDs lower than < 3.33% for the targets. The established PLE and UPLC-PDA method could serve as a rapid and effective method for quality evaluation of Radix Glycyrrhizae. The UPLC technique can be considered as an attractive alternative to HPLC in routine quality control of Chinese medicine, especially in situations where high sample throughput and fast analytical speed are required. Copyright © 2013 John Wiley & Sons, Ltd.
High throughput screening of active pharmaceutical ingredients by UPLC.
Al-Sayah, Mohammad A; Rizos, Panagiota; Antonucci, Vincent; Wu, Naijun
2008-07-01
Ultra performance LC (UPLC) was evaluated as an efficient screening approach to facilitate method development for drug candidates. Three stationary phases were screened: C-18, phenyl, and Shield RP 18 with column dimensions of 150 mm x 2.1 mm, 1.7 microm, which should theoretically generate 35,000 plates or 175% of the typical column plate count of a conventional 250 mm x 4.6 mm, 5 microm particle column. Thirteen different active pharmaceutical ingredients (APIs) were screened using this column set with a standardized mobile-phase gradient. The UPLC method selectivity results were compared to those obtained for these compounds via methods developed through laborious trial and error screening experiments using numerous conventional HPLC mobile and stationary phases. Peak capacity was compared for columns packed with 5 microm particles and columns packed with 1.7 microm particles. The impurities screened by UPLC were confirmed by LC/MS. The results demonstrate that simple, high efficiency UPLC gradients are a feasible and productive alternative to more conventional multiparametric chromatographic screening approaches for many compounds in the early stages of drug development.
Gunn, Josh; Kriger, Scott; Terrell, Andrea R
2010-01-01
The simultaneous determination and quantification of cocaine and its major metabolite, benzoylecgonine, in meconium using UPLC-MS/MS is described. Ultra-performance liquid chromatography (UPLC) is an emerging analytical technique which draws upon the principles of chromatography to run separations at higher flow rates for increased speed, while simultaneously achieving superior resolution and sensitivity. Extraction of cocaine and benzoylecgonine from the homogenized meconium matrix was achieved with a preliminary protein precipitation or protein 'crash' employing cold acetonitrile, followed by a mixed mode solid phase extraction (SPE). Following elution from the SPE cartridge, eluents were dried down under nitrogen, reconstituted in 200 microL of DI water:acetonitrile (ACN) (75:25), and injected onto the UPLC/MS/MS for analysis. The increased speed and separation efficiency afforded by UPLC, allowed for the separation and subsequent quantification of both analytes in less than 2 min. Analytes were quantified using multiple reaction monitoring (MRM) and six-point calibration curves constructed in negative blood. Limits of detection for both analytes were 3 ng/g and the lower limit of quantitation (LLOQ) was 30 ng/g.
Farag, Mohamed A; Gad, Haidy A; Heiss, Andreas G; Wessjohann, Ludger A
2014-05-15
Nigella sativa, commonly known as black cumin seed, is a popular herbal supplement that contains numerous phytochemicals including terpenoids, saponins, flavonoids, alkaloids. Only a few of the ca. 15 species in the genus Nigella have been characterized in terms of phytochemical or pharmacological properties. Here, large scale metabolic profiling including UPLC-PDA-MS and GC-MS with further multivariate analysis was utilized to classify 6 Nigella species. Under optimized conditions, we were able to annotate 52 metabolites including 8 saponins, 10 flavonoids, 6 phenolics, 10 alkaloids, and 18 fatty acids. Major peaks in UPLC-MS spectra contributing to the discrimination among species were assigned as kaempferol glycosidic conjugates, with kaempferol-3-O-[glucopyranosyl-(1→2)-galactopyranosyl-(1→2)-glucopyranoside, identified as potential taxonomic marker for N. sativa. Compared with GC-MS, UPLC-MS was found much more efficient in Nigella sample classification based on genetic and geographical origin. Nevertheless, both GC-MS and UPLC-MS support the remote position of Nigella nigellastrum in relation to the other taxa. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zhuang, Bo; Bi, Zhi-Ming; Wang, Zi-Yuan; Duan, Li; Lai, Chang-Jiang-Sheng; Liu, E-Hu
2018-05-30
Platycladi Cacumen (PC) is a traditional Chinese medicine used for the treatment of hemorrhages, cough, asthma and hair loss. To get a better understanding of the chemical constituents in PC, ultra-high performance liquid chromatography coupled with electrospray ionization quadrupole time-of-flight tandem mass spectrometry (UPLC-Q-TOF-MS/MS) and diagnostic ion filtering strategy were firstly employed for chemical profiling of PC. A total of 43 compounds including organic acids and derivatives, flavonoids as well as phenylpropanolds were unambiguously or reasonably identified. Coumarin and lignan were reported for the first time in PC. Chemical variation of 39 batches of PC from different geographical origins and 10 batches of processed product of PC was subsequently investigated by quantitation of nine major flavonoids. The results determined by UPLC coupled with diode array detection (UPLC-DAD) and hierarchical cluster analysis (HCA) indicated that the contents of flavonoids in PC samples differ greatly. This work provides an efficient approach to comprehensively evaluate the quality of PC. Copyright © 2018 Elsevier B.V. All rights reserved.
Mei, Shenghui; Zhu, Leting; Li, Xingang; Wang, Jiaqing; Jiang, Xueyun; Chen, Haiyan; Huo, Jiping; Yang, Li; Lin, Song; Zhao, Zhigang
2017-01-01
Methotrexate (MTX) plasma concentration is routinely monitored to guide the dosage regimen of rescue drugs. This study aims to develop and validate an ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for plasma MTX analysis, and to establish its agreement with the fluorescence polarization immunoassay (FPIA) in patients with high-dose MTX therapy. Separation was achieved by gradient elution with methanol and water (0.05% formic acid) at 40°C with a run time of 3 min. The intra- and inter-day inaccuracy and imprecision of the UPLC-MS/MS method were -4.25 to 3.1 and less than 7.63%, respectively. The IS-normalized recovery and matrix effect were 87.05 to 92.81 and 124.43 to 134.57%. The correlation coefficients between UPLC-MS/MS and FPIA were greater than 0.98. The UPLC-MS/MS method was in agreement with the FPIA at high levels of MTX (1.0 - 100 μmol/L), but not at low levels (0.01 - 1.0 μmol/L). Further studies are warranted to confirm these results.
2013-01-01
Background Nationally, health in Rwanda has been improving since 2000, with considerable improvement since 2005. Despite improvements, rural areas continue to lag behind urban sectors with regard to key health outcomes. Partners In Health (PIH) has been supporting the Rwanda Ministry of Health (MOH) in two rural districts in Rwanda since 2005. Since 2009, the MOH and PIH have spearheaded a health systems strengthening (HSS) intervention in these districts as part of the Rwanda Population Health Implementation and Training (PHIT) Partnership. The partnership is guided by the belief that HSS interventions should be comprehensive, integrated, responsive to local conditions, and address health care access, cost, and quality. The PHIT Partnership represents a collaboration between the MOH and PIH, with support from the National University of Rwanda School of Public Health, the National Institute of Statistics, Harvard Medical School, and Brigham and Women’s Hospital. Description of intervention The PHIT Partnership’s health systems support aligns with the World Health Organization’s six health systems building blocks. HSS activities focus across all levels of the health system — community, health center, hospital, and district leadership — to improve health care access, quality, delivery, and health outcomes. Interventions are concentrated on three main areas: targeted support for health facilities, quality improvement initiatives, and a strengthened network of community health workers. Evaluation design The impact of activities will be assessed using population-level outcomes data collected through oversampling of the demographic and health survey (DHS) in the intervention districts. The overall impact evaluation is complemented by an analysis of trends in facility health care utilization. A comprehensive costing project captures the total expenditures and financial inputs of the health care system to determine the cost of systems improvement. Targeted evaluations and operational research pieces focus on specific programmatic components, supported by partnership-supported work to build in-country research capacity. Discussion Building on early successes, the work of the Rwanda PHIT Partnership approach to HSS has already seen noticeable increases in facility capacity and quality of care. The rigorous planned evaluation of the Partnership’s HSS activities will contribute to global knowledge about intervention methodology, cost, and population health impact. PMID:23819573
Drobac, Peter C; Basinga, Paulin; Condo, Jeanine; Farmer, Paul E; Finnegan, Karen E; Hamon, Jessie K; Amoroso, Cheryl; Hirschhorn, Lisa R; Kakoma, Jean Baptise; Lu, Chunling; Murangwa, Yusuf; Murray, Megan; Ngabo, Fidele; Rich, Michael; Thomson, Dana; Binagwaho, Agnes
2013-01-01
Nationally, health in Rwanda has been improving since 2000, with considerable improvement since 2005. Despite improvements, rural areas continue to lag behind urban sectors with regard to key health outcomes. Partners In Health (PIH) has been supporting the Rwanda Ministry of Health (MOH) in two rural districts in Rwanda since 2005. Since 2009, the MOH and PIH have spearheaded a health systems strengthening (HSS) intervention in these districts as part of the Rwanda Population Health Implementation and Training (PHIT) Partnership. The partnership is guided by the belief that HSS interventions should be comprehensive, integrated, responsive to local conditions, and address health care access, cost, and quality. The PHIT Partnership represents a collaboration between the MOH and PIH, with support from the National University of Rwanda School of Public Health, the National Institute of Statistics, Harvard Medical School, and Brigham and Women's Hospital. The PHIT Partnership's health systems support aligns with the World Health Organization's six health systems building blocks. HSS activities focus across all levels of the health system - community, health center, hospital, and district leadership - to improve health care access, quality, delivery, and health outcomes. Interventions are concentrated on three main areas: targeted support for health facilities, quality improvement initiatives, and a strengthened network of community health workers. The impact of activities will be assessed using population-level outcomes data collected through oversampling of the demographic and health survey (DHS) in the intervention districts. The overall impact evaluation is complemented by an analysis of trends in facility health care utilization. A comprehensive costing project captures the total expenditures and financial inputs of the health care system to determine the cost of systems improvement. Targeted evaluations and operational research pieces focus on specific programmatic components, supported by partnership-supported work to build in-country research capacity. Building on early successes, the work of the Rwanda PHIT Partnership approach to HSS has already seen noticeable increases in facility capacity and quality of care. The rigorous planned evaluation of the Partnership's HSS activities will contribute to global knowledge about intervention methodology, cost, and population health impact.
Eskelinen, Matti; Ollonen, Paula
2011-11-01
The findings of a repressed expression of emotions in cancer patients contributed to the hypothesis developed by Lydia Temoshok of a type C personality ('cancer-prone'). To the Authors' knowledge, the associations between the 'cancer-prone personality' characteristics in commitment test and the risk of breast cancer (BC) have rarely been considered together in a prospective study. In an extension of the Kuopio Breast Cancer Study, 115 women with breast symptoms were evaluated for commitment test before any diagnostic procedures were carried out. The clinical examination and biopsy showed BC in 34 patients, benign breast disease (BBD) in 53 patients and 28 individuals were shown to be healthy study subjects (HSS). The BC group reported significantly more commitment to own children (Function A) (mean Commitment score, 3.14) than the patients in the BBD group (mean Commitment score, 3.51) and in the HSS group (mean Commitment score, 3.77) (p=0.05). The women in the BC group also reported more commitment to own husband (Function B) (mean Commitment score, 3.30) than the patients in the BBD group (mean Commitment score, 3.83) and the patients in the HSS group (mean Commitment score, 3.76). The BC group reported significantly more commitment to own work and own body (Function D and G) (mean Commitment scores, 3.20 and 3.50) than the patients in the BBD group (mean Commitment scores, 3.75 and 3.71) or HSS group (mean Commitment scores, 3.46 and 3.50). The mean sum (mean, SD) of the scores were significantly lower in the BC group (31.1, 5.8) than in the BBD (35.2, 6.9) and HSS group (36.4, 5.6) (p=0.02), showing more commitment in the BC group. In summary, patients with BC tended to have an increased risk for bearing the 'high commitment' characteristic and this pattern could contribute to cancer risk through immune and hormonal pathways.
Queirós, Andréa Simone Siqueira de; Brandão, Simone Cristina Soares; Domingues, Ana Lúcia Coutinho; Macedo, Liana Gonçalves; Ourem, Maira Souto; Lopes, Edmundo Pessoa Almeida
2014-06-01
Portal hypertension is responsible for various complications in patients with schistosomiasis, among them intrapulmonary vascular dilations (IPVD). In cirrhotic patients the presence of IPVD is a sign of poor prognosis, but in patients with hepatosplenic schistosomiasis (HSS) there are no studies assessing the significance of this change. The aim of this study was to evaluate the occurrence of IPVD through 99mTc-MAA scintigraphy in patients with HSS and its relationship with clinical, laboratory, endoscopic and ultrasound parameters. Cross-sectional study evaluating 51 patients with HSS. Patients were diagnosed with IPVD when the brain uptake of 99mTc-MAA was higher than 6%. Subsequently, they were divided according to presence (G1) or absence (G2) of IPVD and variables were compared between groups. Overall, 51 patients with mean age of 56±12 years were assessed. IPVD was observed in 31 patients (60%). There was no statistically significant differences between groups when clinical, laboratory and endoscopic parameters were compared. Regarding ultrasound parameters, the splenic vein diameter was smaller in G1 (0.9 ± 0.3 cm) compared to G2 (1.2 ± 0.4 cm), p=0.029. In patients with HSS, the occurrence of IPVD by 99mTc-MAA scintigraphy was high and was associated with lower splenic vein diameter, which can be a mechanism of vascular protection against portal hypertension. However, more studies are needed to determine the clinical significance of the early diagnosis and natural evolution of IPVD in this population.
Wild, Beate; Stadnitski, Tatjana; Wesche, Daniela; Stroe-Kunold, Esther; Schultz, Jobst-Hendrik; Rudofsky, Gottfried; Maser-Gluth, Christiane; Herzog, Wolfgang; Friederich, Hans-Christoph
2016-04-01
The aim of the study was to investigate the characteristics of the awakening salivary cortisol in patients with anorexia nervosa (AN) using a time series design. We included ten AN inpatients, six with a very low BMI (high symptom severity, HSS group) and four patients with less severe symptoms (low symptom severity, LSS group). Patients collected salivary cortisol daily upon awakening. The number of collected saliva samples varied across patients between n=65 and n=229 (due to the different lengths of their inpatient stay). In addition, before retiring, the patients answered questions daily on the handheld regarding disorder-related psychosocial variables. The analysis of cortisol and diary data was conducted by using a time series approach. Time series showed that the awakening cortisol of the AN patients was elevated as compared to a control group. Cortisol measurements of patients with LSS essentially fluctuated in a stationary manner around a constant mean. The series of patients with HSS were generally less stable; four HSS patients showed a non-stationary cortisol awakening series. Antipsychotic medication did not change awakening cortisol in a specific way. The lagged dependencies between cortisol and depressive feelings became significant for four patients. Here, higher cortisol values were temporally associated with higher values of depressive feelings. Upon awakening, the cortisol of all AN patients was in the standard range but elevated as compared to healthy controls. Patients with HSS appeared to show less stable awakening cortisol time series compared to patients with LSS. Copyright © 2016 Elsevier B.V. All rights reserved.
Grundy, John; Moodie, Rob
2009-01-01
The Democratic Peoples Republic of Korea (DPRK), under the leadership of the Ministry of Public Health (MOPH), undertook the development of a Health System Strengthening (HSS) proposal through the support of the Global Alliance for Vaccines and Immunization (GAVI). The aim of this paper is to outline the approach to the development of the HSS strategy in DPRK, and describe opportunities and challenges associated with its development and future implementation. Sources of information for this review have included national programme plans, in country social sector reviews, information generated through HSS proposal developments and the international literature. Updated assessments in DPRK indicate some recent improvements in the health situation for women and children, but there remain ongoing concerns regarding health management, human resource and physical infrastructure barriers to health services access. In response to this situation, the DPRK developed a health system strengthening strategy, the main elements of which are the strengthening of health management and service delivery systems at the implementing agency levels of county (district) and Ri (sub district). Three success factors were associated with the reaching of consensus on HSS strategy in DPRK. These were partnerships formed between system planners and programme planners, the identification of an overall health sector strategic framework, and high-level leadership of the MOPH. Although DPRK is in the very early stages of health system reconstruction, there are significant and new opportunities to alleviate the health conditions of women and children in DPRK, through implementation of health system strengthening strategies that are nationally coordinated and internationally supported.
The Hospital for Special Surgery 1972–1989; Philip D. Wilson, Jr., Eighth Surgeon-in-Chief
2010-01-01
After nearly a decade as the seventh Surgeon-in-Chief (1963–1972) of The Hospital for Special Surgery (HSS), Robert Lee Patterson, Jr., MD (1907–1994) retired, having repaired adverse relations between HSS and the New York Hospital-Cornell Medical Center. Patterson, who had first joined the staff of The Hospital for the Ruptured and Crippled in 1936 as a Visiting Surgeon, was able to accomplish this very challenging task mainly through his close relationship with Preston Wade, MD (1901–1982), a general surgeon who had served with Patterson as Co-Chief of the combined New York Hospital-HSS Fracture service. The Board of Trustees of the New York Society for the Relief of the Ruptured and Crippled appointed Philip D. Wilson, Jr. MD, as the eighth Surgeon-in-Chief of The Hospital for Special Surgery. He assumed that office on July 1, 1972. Wilson, who had joined the staff as an Orthopaedic Surgeon to the Out-Patient Department in 1951, had trained as an orthopaedic resident at HSS from 1948 to 1950 and in 1951, finished his residency at the University of California Hospital Medical Center, San Francisco. During his 17 years as Surgeon-in-Chief, he led the hospital into the advanced field of implant research and development and building a world-class center for patient care. Additionally, many other orthopaedic services such as Sports Medicine, Scoliosis and Metabolic Bone Diseases became the leaders in their fields. Supporting Departments of Rheumatology, Anesthesia and others were likewise recognized foremost in the country. PMID:21886524
Effect of humic substance photodegradation on bacterial growth and respiration in lake water
Anesio, A.M.; Graneli, W.; Aiken, G.R.; Kieber, D.J.; Mopper, K.
2005-01-01
This study addresses how humic substance (HS) chemical composition and photoreactivity affect bacterial growth, respiration, and growth efficiency (BGE) in lake water. Aqueous solutions of HSs from diverse aquatic environments representing different dissolved organic matter sources (autochthonous and allochthonous) were exposed to artificial solar UV radiation. These solutions were added to lake water passed through a 0.7-??m-pore-size filter (containing grazer-free lake bacteria) followed by dark incubation for 5, 43, and 65 h. For the 5-h incubation, several irradiated HSs inhibited bacterial carbon production (BCP) and this inhibition was highly correlated with H 2O2 photoproduction. The H2O2 decayed in the dark, and after 43 h, nearly all irradiated HSs enhanced BCP (average 39% increase relative to nonirradiated controls, standard error = 7.5%, n = 16). UV exposure of HSs also increased bacterial respiration (by ???18%, standard error = 5%, n = 4), but less than BCP, resulting in an average increase in BGE of 32% (standard error = 10%, n = 4). Photoenhancement of BCP did not correlate to HS bulk properties (i.e., elemental and chemical composition). However, when the photoenhancement of BCP was normalized to absorbance, several trends with HS origin and extraction method emerged. Absorbance-normalized hydrophilic acid and humic acid samples showed greater enhancement of BCP than hydrophobic acid and fulvic acid samples. Furthermore, absorbance-normalized autochthonous samples showed ???10-fold greater enhancement of BCP than allochthonous-dominated samples, indicating that the former are more efficient photoproducers of biological substrates. Copyright ?? 2005, American Society for Microbiology. All Rights Reserved.
Diagnosis and body mass index effects on hippocampal volumes and neurochemistry in bipolar disorder.
Bond, D J; Silveira, L E; MacMillan, E L; Torres, I J; Lang, D J; Su, W; Honer, W G; Lam, R W; Yatham, L N
2017-03-28
We previously reported that higher body mass index (BMI) was associated with greater hippocampal glutamate+glutamine in people with bipolar disorder (BD), but not in non-BD healthy comparator subjects (HSs). In the current report, we extend these findings by examining the impact of BD diagnosis and BMI on hippocampal volumes and the concentrations of several additional neurochemicals in 57 early-stage BD patients and 31 HSs. Using 3-T magnetic resonance imaging and magnetic resonance spectroscopy, we measured bilateral hippocampal volumes and the hippocampal concentrations of four neurochemicals relevant to BD: N-acetylaspartate+N-acteylaspartylglutamate (tNAA), creatine+phosphocreatine (Cre), myoinositol (Ins) and glycerophosphocholine+phosphatidylcholine (Cho). We used multivariate factorial analysis of covariance to investigate the impact of diagnosis (patient vs HS) and BMI category (normal weight vs overweight/obese) on these variables. We found a main effect of diagnosis on hippocampal volumes, with patients having smaller hippocampi than HSs. There was no association between BMI and hippocampal volumes. We found diagnosis and BMI effects on hippocampal neurochemistry, with patients having lower Cre, Ins and Cho, and overweight/obese subjects having higher levels of these chemicals. In patient-only models that controlled for clinical and treatment variables, we detected an additional association between higher BMI and lower tNAA that was absent in HSs. To our knowledge, this was the first study to investigate the relative contributions of BD diagnosis and BMI to hippocampal volumes, and only the second to investigate their contributions to hippocampal chemistry. It provides further evidence that diagnosis and elevated BMI both impact limbic brain areas relevant to BD.
NASA Astrophysics Data System (ADS)
Zhang, Yaoling; Du, Jinzhou; Zhao, Xin; Wu, Wangsuo; Peng, Bo; Zhang, Jing
2014-12-01
To better understand the origin, composition, and reactivity of sedimentary humic substances (HSs) in salt marshes in the Changjiang Estuary, HS samples were isolated from a sediment core that was collected from the Eastern Chongming salt marsh. Chemical and spectroscopic methods were used to analyze the features of these HSs. The results indicate that the studied HSs in the salt marsh sediments are mainly terrestrial-derived and that the sedimentary organic matter (SOM) in the top layer may contain more organic matter from marine sources and/or autochthonous materials due to the dramatic decreasing of the sediment supply as a result of damming. The degradation of labile carbohydrates and proteins and the preservation of refractory lignin components dominate the early diagenetic reactions of SOM in the salt marsh area. The average contents of the carboxylic groups in FAs and HAs are 11.64 ± 1.08 and 7.13 ± 0.16 meq/gC, and those of phenolic groups are 1.95 ± 0.13 and 2.40 ± 0.44 meq/gC, respectively. The content of carboxylic groups increased with increasing depth, while there were no obvious changes in the content of phenolic groups. The average concentration of total proton-binding sites is approximately 12.5 μmol/g sediment for the studied HSs. These values may provide insight into the migration and fate of HS-bound contaminants in sediments and the overlying sea water in the salt marsh areas of the Changjiang Estuary.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghysels, Pieter; Li, Xiaoye S.; Rouet, Francois -Henry
Here, we present a sparse linear system solver that is based on a multifrontal variant of Gaussian elimination and exploits low-rank approximation of the resulting dense frontal matrices. We use hierarchically semiseparable (HSS) matrices, which have low-rank off-diagonal blocks, to approximate the frontal matrices. For HSS matrix construction, a randomized sampling algorithm is used together with interpolative decompositions. The combination of the randomized compression with a fast ULV HSS factoriz ation leads to a solver with lower computational complexity than the standard multifrontal method for many applications, resulting in speedups up to 7 fold for problems in our test suite.more » The implementation targets many-core systems by using task parallelism with dynamic runtime scheduling. Numerical experiments show performance improvements over state-of-the-art sparse direct solvers. The implementation achieves high performance and good scalability on a range of modern shared memory parallel systems, including the Intel Xeon Phi (MIC). The code is part of a software package called STRUMPACK - STRUctured Matrices PACKage, which also has a distributed memory component for dense rank-structured matrices.« less
[Individual differences in strategy use in the Japanese reading span test].
Endo, Kaori; Osaka, Mariko
2012-02-01
Working memory is a system for processing and storing information. The Reading Span Test (RST), developed by Daneman and Carpenter (1980), is well-known for assessing individual difference in working memory. In the present investigation, we used the Japanese version of the RST (Osaka, 2002) and analyzed individual differences in strategy use from the viewpoint of strategy type (rehearsal, chaining, word-image, scene-image, and initial letter) and frequency of use (used in almost all trials, in half the trials, or not used). Data from the participants (N = 132) were assigned to groups according to the scores, for the total number of words correctly recalled and the proportion correct. The results showed that the frequency of word-image strategy use differed significantly between high-scoring subjects (HSS) and low-scoring subjects (LSS). HSS mainly used word-image and chaining strategies, while LSS used rehearsal and chaining strategies. This indicates that HSS used both verbal and visual strategies, whereas LSS relied only on verbal strategies. The use of the word-image is important for effective retention of words in memory.
Zhong, Guangjun; Liang, Zhu; Kan, Jiang; Muheremu, Aikeremujiang
2018-01-01
Objective This study was performed to determine the efficacy of selective peripheral nerve resection for treatment of persistent neuropathic pain after total knee arthroplasty (TKA). Methods Patients who underwent TKA in our department from January 2013 to July 2016 and experienced persistent pain around the knee joint after TKA were retrospectively included in the current study. Sixty patients were divided into experimental and control groups according the treatment they received. The treatment effect was evaluated by the Hospital for Special Surgery (HSS) knee score and visual analog scale (VAS) pain score preoperatively and at 1, 2, 3, 6, and 12 months postoperatively. Results The HSS knee scores were higher in both groups after than before the treatment, and HSS knee scores were significantly higher in the experimental group than in the control group. The VAS pain scores were lower in both groups after than before the treatment, and VAS pain scores were significantly lower in the experimental group than in the control group. Conclusions Selective peripheral nerve resection is an effective treatment method for persistent neuropathic pain after TKA.
Wisniewski, Janna M; Yeager, Valerie A; Diana, Mark L; Hotchkiss, David R
2016-10-01
The number of health systems strengthening (HSS) programs has increased in the last decade. However, a limited number of studies providing robust evidence for the value and impact of these programs are available. This study aims to identify knowledge gaps and challenges that impede rigorous monitoring and evaluation (M&E) of HSS, and to ascertain the extent to which these efforts are informed by existing technical guidance. Interviews were conducted with HSS advisors at United States Agency for International Development-funded missions as well as senior M&E advisors at implementing partner and multilateral organizations. Findings showed that mission staff do not use existing technical resources, either because they do not know about them or do not find them useful. Barriers to rigorous M&E included a lack suitable of indicators, data limitations, difficulty in demonstrating an impact on health, and insufficient funding and resources. Consensus and collaboration between international health partners and local governments may mitigate these challenges. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Gungor, O Erken; Nur, B Guzel; Yalcin, H; Karayilmaz, H; Mihci, E
2015-01-01
Hallermann-Streiff syndrome (HSS) is a genetic disorder characterized by proportionate dwarfism, birdlike facies, hypotrichosis, skin atrophy, dyscephaly, bilateral microphthalmia, congenital cataracts, a narrow, weak, beaked nose, a hypoplastic mandible, and orodental anomalies. Occurrence is sporadic and distinct patterns of inheritance have not been found. This case report describes the dental management of a 3-year-old girl patient with HSS, who had unusual radiographic appearance of teeth. Furthermore, dental treatments and a 30-month follow-up period of the patient with this rare tooth structure malformation have been presented.
Johnson, Caroline H.; Patterson, Andrew D.; Krausz, Kristopher W.; Lanz, Christian; Kang, Dong Wook; Luecke, Hans; Gonzalez, Frank J.; Idle, Jeffrey R.
2011-01-01
Radiation metabolomics has aided in the identification of a number of biomarkers in cells and mice by ultra-performance liquid chromatography-coupled time-of-flight mass spectrometry (UPLC-ESI-QTOFMS) and in rats by gas chromatography-coupled mass spectrometry (GCMS). These markers have been shown to be both dose- and time-dependent. Here UPLC-ESI-QTOFMS was used to analyze rat urine samples taken from 12 rats over 7 days; they were either sham-irradiated or γ-irradiated with 3 Gy after 4 days of metabolic cage acclimatization. Using multivariate data analysis, nine urinary biomarkers of γ radiation in rats were identified, including a novel mammalian metabolite, N-acetyltaurine. These upregulated urinary biomarkers were confirmed through tandem mass spectrometry and comparisons with authentic standards. They include thymidine, 2′-deoxyuridine, 2′deoxyxanthosine, N1-acetylspermidine, N-acetylglucosamine/galactosamine-6-sulfate, N-acetyltaurine, N-hexanoylglycine, taurine and, tentatively, isethionic acid. Of these metabolites, 2′-deoxyuridine and thymidine were previously identified in the rat by GCMS (observed as uridine and thymine) and in the mouse by UPLC-ESI-QTOFMS. 2′Deoxyxanthosine, taurine and N-hexanoylglycine were also seen in the mouse by UPLC-ESI-QTOFMS. These are now unequivocal cross-species biomarkers for ionizing radiation exposure. Downregulated biomarkers were shown to be related to food deprivation and starvation mechanisms. The UPLC-ESI-QTOFMS approach has aided in the advance for finding common biomarkers of ionizing radiation exposure. PMID:21309707
Wang, Shuya; Li, Ding; Pi, Jiaxin; Li, Wen; Zhang, Bing; Qi, Dongli; Li, Nan; Guo, Pan; Liu, Zhidong
2017-11-01
The purpose of this work was to determine and investigate the absorption of ginkgo terpenoids (GT) in plasma and aqueous humour after oral administration of ginkgo biloba extract (GBE) by UPLC-MS/MS method. The UPLC-MS/MS determination of GT employed the multiple reaction monitoring mode using an electrospray negative ionization. The rabbits were orally administered the suspension of GBE at a dose of 500 mg/kg. Serial plasma and dialysate samples were collected at the corresponding time and then analysed by UPLC-MS/MS. In plasma, the mean AUC from 0 to 48 h was 14.12, 12.59, 23.75, 1.51 h μg/ml for GLJ and 5.34 h μg/ml for GLA, GLB, GLC, GLJ and BLL, respectively. In aqueous humour, the five ginkgo terpenoids have been detected. Compared with the other four GT, BLL has better absorption in the eyes. A selective and reproducible UPLC-MS/MS method was developed and validated to determine and investigate the absorption of ginkgo terpenoids in plasma and aqueous humour of rabbits after oral administration of GBE. The main five ginkgo terpenoids could be absorbed into eyes. © 2017 Royal Pharmaceutical Society.
Zhang, Li; Shen, Hong; Xu, Jun; Xu, Jin-Di; Li, Zhen-Ling; Wu, Jie; Zou, Ye-Ting; Liu, Li-Fang; Li, Song-Lin
2018-04-25
In this study, a novel ultra-performance liquid chromatography coupled with quadrupole/time-of-flight mass spectrometry (UPLC-QTOF-MS/MS)-guidance strategy was proposed for preparation of sulfur-containing derivatives in sulfur-fumigated edible herbs. Being versatile in both chromatographic separation and mass spectrometric detection, UPLC-QTOF-MS/MS was inducted into each experimental step for multifaceted purposes including finding, tracking, purity determination and structural elucidation of targeted compounds as well as UPLC-HPLC chromatographic conditions transplantation, whereby the isolation and purification procedures were greatly facilitated. Using this strategy, a new sulfur-containing ginsenoside Rg 1 derivative (named compound I) was obtained from sulfur-fumigated ginseng. The chemical structure of compound I was elucidated to be (3β, 6α, 12β)-3, 12-dihydroxydammar-25-ene-6, 20-diylbis-β-d-glucopyranoside, 24-sulfonic acid by QTOF-MS/MS, 1 H-NMR and 13 C-NMR analysis, and its generation mechanisms by sulfur-fumigation were accordingly discussed. The research deliverable suggests that the UPLC-QTOF-MS/MS-guidance strategy is promising for targeted preparation of sulfur-containing derivatives from sulfur-fumigated edible herbs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Eskelinen, Matti; Ollonen, Paula
2011-05-01
Trait anxiety (T-Anxiety) was assessed using the subscale from the Spielberger State-Trait Anxiety Inventory test (STAI form Y-2), with statements refering to how a person generally feels, and a higher total score reflecting a higher T-Anxiety. To the authors' knowledge, the associations between the STAI test and the risk of breast cancer (BC) are rarely considered together in a prospective study. In an extension of the Kuopio Breast Cancer Study 115 women with breast symptoms were evaluated for anxiety using the STAI form Y-2 test before any diagnostic procedures were carried out. The clinical examination and biopsy showed BC in 34 patients, benign breast disease (BBD) in 53 patients and 28 individuals were shown to be healthy study subjects (HSS). There was a trend for the HSS women to have less severe anxiety in the STAI test (1/28 patients, 3.6%) than those in the BBD (7/53 patients, 13.2%) and BC groups (4/34 patients, 11.8%). The subjects in the HSS group reported being significantly more happy in the STAI test (STAI mean score, 1.54) than the BBD group (STAI mean score, 1.98) and the BC group (STAI mean score, 2.00) (p=0.01). The subjects in the HSS group also reported being more content in the STAI test (STAI mean score, 1.68) than the BBD group (STAI mean score, 1.87) and the BC group (STAI mean score, 1.97). Patients with BC and BBD tend to have more unhappy and uncontent feelings, but no specific link between the STAI test (form Y-2) and breast cancer risk is supported.
Current Therapeutic Approach to Hypertrophic Scars
Mokos, Zrinka Bukvić; Jović, Anamaria; Grgurević, Lovorka; Dumić-Čule, Ivo; Kostović, Krešimir; Čeović, Romana; Marinović, Branka
2017-01-01
Abnormal scarring and its accompanying esthetic, functional, and psychological sequelae still pose significant challe nges. To date, there is no satisfactory prevention or treatment option for hypertrophic scars (HSs), which is mostly due to not completely comprehending the mechanisms underlying their formation. That is why the apprehension of regular and controlled physiological processes of scar formation is of utmost importance when facing hypertrophic scarring, its pathophysiology, prevention, and therapeutic approach. When treating HSs and choosing the best treatment and prevention modality, physicians can choose from a plethora of therapeutic options and many commercially available products, among which currently there is no efficient option that can successfully overcome impaired skin healing. This article reviews current therapeutic approach and emerging therapeutic strategies for the management of HSs, which should be individualized, based on an evaluation of the scar itself, patients’ expectations, and practical, evidence-based guidelines. Clinicians are encouraged to combine various prevention and treatment modalities where combination therapy that includes steroid injections, 5-fluorouracil, and pulsed-dye laser seems to be the most effective. On the other hand, the current therapeutic options are usually empirical and their results are unreliable and unpredictable. Therefore, there is an unmet need for an effective, targeted therapy and prevention, which would be based on an action or a modulation of a particular factor with clarified mechanism of action that has a beneficial effect on wound healing. As the extracellular matrix has a crucial role in cellular and extracellular events that lead to pathological scarring, targeting its components mostly by regulating bone morphogenetic proteins may throw up new therapeutic approach for reduction or prevention of HSs with functionally and cosmetically acceptable outcome. PMID:28676850
Dogan, Didem C; Cho, Seonghun; Hwang, Sun-Mi; Kim, Young-Min; Guim, Hwanuk; Yang, Tae-Hyun; Park, Seok-Hee; Park, Gu-Gon; Yim, Sung-Dae
2016-10-10
Supportless Pt catalysts have several advantages over conventional carbon-supported Pt catalysts in that they are not susceptible to carbon corrosion. However, the need for high Pt loadings in membrane electrode assemblies (MEAs) to achieve state-of-the-art fuel cell performance has limited their application in proton exchange membrane fuel cells. Herein, we report a new approach to the design of a supportless Pt catalyst in terms of catalyst layer architecture, which is crucial for fuel cell performance as it affects water management and oxygen transport in the catalyst layers. Large Pt hollow spheres (PtHSs) 100 nm in size were designed and prepared using a carbon template method. Despite their large size, the unique structure of the PtHSs, which are composed of a thin-layered shell of Pt nanoparticles (ca. 7 nm thick), exhibited a high surface area comparable to that of commercial Pt black (PtB). The PtHS structure also exhibited twice the durability of PtB after 2000 potential cycles (0-1.3 V, 50 mV/s). A MEA fabricated with PtHSs showed significant improvement in fuel cell performance compared to PtB-based MEAs at high current densities (>800 mA/cm 2 ). This was mainly due to the 2.7 times lower mass transport resistance in the PtHS-based catalyst layers compared to that in PtB, owing to the formation of macropores between the PtHSs and high porosity (90%) in the PtHS catalyst layers. The present study demonstrates a successful example of catalyst design in terms of catalyst layer architecture, which may be applied to a real fuel cell system.
Deng, Yao-Tiao; Liu, Jie; Zhang, Jie; Huang, Bo-Yan; Yi, Ting-Wu; Wang, Yu-Qing; Zheng, Bo; Luo, Di; Du, Pei-Xin; Jiang, Yu
2017-08-01
The objective of the study is to develop a novel tool-the Burnout Battery-for briefly screening burnout among oncology professionals in China and assessing its validity. A multicenter study was conducted in doctors and nurses of the oncology departments in China from November 2014 to May 2015. The Burnout Battery was administered with the Maslach Burnout Inventory-Human Services Survey (MBI-HSS) and the Doctors' Job Burnout Questionnaire. Of 538 oncology doctors and nurses who completed all the survey, using MBI-HSS as the standard tool for measuring burnout, 52% had emotional exhaustion, 39.4% had depersonalization, and 59.3% had a low sense of personal accomplishment. Receiver operating characteristic curve analyses showed that the best cut-off of the Burnout Battery was the battery with 3 bars, which yielded best sensitivity and specificity against all the 3 subscales of MBI-HSS. With this cut-off, nearly half of Chinese oncology professionals (46.8%) had burnout. The Burnout Battery correlated significantly with subscales of the MBI-HSS and the Doctors' Job Burnout Questionnaire. In multiple logistic regression analysis, those who worked more than 60 hours per week and who thought clinical work was the most stressful part of their job were more likely to experience burnout. Chinese oncology professionals exhibit high levels of burnout. The Burnout Battery appears to be a simple and useful tool for screening burnout. Working long hours and perceiving clinical work as the most stressful part of the job were the main factors associated with burnout. Copyright © 2016 John Wiley & Sons, Ltd.
Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D
2014-10-01
Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.
Heo, Seok; Yoo, Geum Joo; Choi, Ji Yeon; Park, Hyoung Joon; Do, Jung-Ah; Cho, Sooyeul; Baek, Sun Young; Park, Sung-Kwan
2016-06-01
The primary purpose of this study was to develop and validate a method based on UPLC with UV and UPLC-MS-MS for the simultaneous analysis of different cannabinoids and synthetic cannabinoids in food as well as in herbal and dietary supplements. The limits of detection and quantitation of the method ranged from 0.1 to 0.3 and 0.3 to 0.9 μg/mL by UPLC with UV, respectively. The coefficient of determination was >0.999; the intra- and interday precision of the method were 0.1-3.7 and 0.9-4.1%, respectively. The intra- and interday accuracy were 94.8-103.1 and 98.3-100.9%, respectively. The mean recoveries of nine cannabinoids obtained from tablet samples ranged from 81.1 to 105.4%. The mean extraction recoveries of nine target cannabinoids obtained from various types of samples (tablets, capsules, powders, liquids, cookies and candies) ranged from 82.26 to 112.40%. The relative standard deviation (RSD) of the stability of the prepared sample solutions was <1.80%. Identification and quantification of the nine cannabinoids were accomplished by ion spray UPLC-MS-MS using multiple reaction monitoring. The UPLC-MS-MS method was validated for linearity (R(2) > 0.99); the precision was 0.1-4.0% (intraday) and 0.1-2.8% (interday), and the accuracy was 98.0-103.5% (intraday) and 97.1-103.2% (interday). The mean extraction recoveries of six types of samples were 82.2-114.5% and the RSD of stability was <6.54%, complying with the established international guidelines. The results indicated that the method can be used for rapid and accurate screening of cannabinoids present in food. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Deng, Haishan; Shang, Erxin; Xiang, Bingren; Xie, Shaofei; Tang, Yuping; Duan, Jin-ao; Zhan, Ying; Chi, Yumei; Tan, Defei
2011-03-15
The stochastic resonance algorithm (SRA) has been developed as a potential tool for amplifying and determining weak chromatographic peaks in recent years. However, the conventional SRA cannot be applied directly to ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOFMS). The obstacle lies in the fact that the narrow peaks generated by UPLC contain high-frequency components which fall beyond the restrictions of the theory of stochastic resonance. Although there already exists an algorithm that allows a high-frequency weak signal to be detected, the sampling frequency of TOFMS is not fast enough to meet the requirement of the algorithm. Another problem is the depression of the weak peak of the compound with low concentration or weak detection response, which prevents the simultaneous determination of multi-component UPLC/TOFMS peaks. In order to lower the frequencies of the peaks, an interpolation and re-scaling frequency stochastic resonance (IRSR) is proposed, which re-scales the peak frequencies via linear interpolating sample points numerically. The re-scaled UPLC/TOFMS peaks could then be amplified significantly. By introducing an external energy field upon the UPLC/TOFMS signals, the method of energy gain was developed to simultaneously amplify and determine weak peaks from multi-components. Subsequently, a multi-component stochastic resonance algorithm was constructed for the simultaneous quantitative determination of multiple weak UPLC/TOFMS peaks based on the two methods. The optimization of parameters was discussed in detail with simulated data sets, and the applicability of the algorithm was evaluated by quantitative analysis of three alkaloids in human plasma using UPLC/TOFMS. The new algorithm behaved well in the improvement of signal-to-noise (S/N) compared to several normally used peak enhancement methods, including the Savitzky-Golay filter, Whittaker-Eilers smoother and matched filtration. Copyright © 2011 John Wiley & Sons, Ltd.
Wang, Zhenlei; Jiang, Ji; Hu, Pei; Zhao, Qian
2017-02-01
Fotagliptin is a novel dipeptidyl peptidase IV inhibitor under clinical development for the treatment of Type II diabetes mellitus. The objective of this study was to develop and validate a specific and sensitive ultra-performance liquid chromatography (UPLC)-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine. Methodology & results: After being pretreated using an automatized procedure, the plasma and urine samples were separated and detected using a UPLC-ESI-MS/MS method, which was validated following the international guidelines. A selective and sensitive UPLC-MS/MS method was first developed and validated for quantifying fotagliptin and its metabolite in human plasma and urine. The method was successfully applied to support the clinical study of fotagliptin in Chinese healthy subjects.
Quantitative analysis of boeravinones in the roots of Boerhaavia Diffusa by UPLC/PDA.
Bairwa, Khemraj; Srivastava, Amit; Jachak, Sanjay Madhukar
2014-01-01
Boerhaavia diffusa is a perennial herb belonging to Nyctaginaceae. Various classes of chemical constituents such as phenolics (boeravinones), terpenoids and organic acids have been reported in B. diffusa roots. As boeravinones have been proposed as putative active constituents for the anti-cancer, spasmolytic and anti-inflammatory activities exhibited by B. diffusa extracts, it is worthwhile developing and validating an ultra-performance liquid chromatography (UPLC) method for analysis of boeravinones in B. diffusa roots. To develop and validate a simple, accurate, robust and rapid UPLC analytical method for quality control of B. diffusa roots. Samples for analysis were prepared by refluxing powdered root material with methanol for 2 h. The extracts were concentrated, dried and stored at -20°C until their use. A UPLC with photodiode array (PDA) method was developed and validated for the quantification of boeravinones in the roots of B. diffusa. The separation of boeravinones was achieved using a BEH Shield C18 -column (2.1 × 100 mm, 1.7 µm) with gradient elution of methanol and water (0.1% acetic acid), at a flow rate of 0.4 mL/min and detection was carried out at λmax 273 nm. The UPLC method developed showed good linearity (r(2) ≥ 0.9999), accuracy and precision. The UPLC method developed provided a selective, sensitive and rapid analytical method for the quantification of boeravinones in B. diffusa roots. All the validation parameters were found to be within the permissible limits as per International Conference on Harmonisation guidelines. Copyright © 2014 John Wiley & Sons, Ltd.
Chen, H; Hu, X; Yang, G; Xiang, M
2017-04-01
Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.
Differing HIV vulnerability among female sex workers in a high HIV burden Indian state.
Mamulwar, Megha; Godbole, Sheela; Bembalkar, Shilpa; Kamble, Pranil; Dulhani, Nisha; Yadav, Rajesh; Kadu, Chitra; Kumar, Pradeep; Lalikar, Shivraj; Acharya, Shrikala; Gangakhedkar, Raman; Risbud, Arun; Venkatesh, Srinivas
2018-01-01
The HIV sentinel surveillance [HSS] conducted in 2010-11 among female sex workers [FSW] in the state of Maharashtra, India provided an opportunity to assess characteristics of different types of FSWs and their HIV risk. It is important for India's National AIDS Control Program, to understand the differences in vulnerability among these FSW, in order to define more specific and effective risk reduction intervention strategies. Therefore, we analyzed data from HSS with the objective of understanding the HIV vulnerability among different types of FSW in Maharashtra. Cross sectional data collected as a part of HSS among FSWs in year 2010-11 from 21 sentinel sites in the state of Maharashtra were analyzed to understand the vulnerability and characteristics of different types of female sex workers based on their place of solicitation using multinomial logistic regression. While the HIV prevalence was 6.6% among all FSWs, it was 9.9% among brothel based [BB], 9% among street based [SB] and 3.1% and 3.7% among home based [HB], and bar based [Bar-B] sex workers respectively. SB FSWs were least likely to be located in HIV low burden districts [ANC] [ARRR: 0.61[95% CI: 0.49, 0.77
HLA-A*31:01 and HLA-B*15:02 as genetic markers for carbamazepine hypersensitivity in children
Amstutz, Ursula; Ross, Colin J.D.; Castro-Pastrana, Lucila I.; Rieder, Michael J.; Shear, Neil H.; Hayden, Michael R.; Carleton, Bruce C.
2013-01-01
The occurrence of hypersensitivity reactions including rare but life-threatening Stevens-Johnson syndrome (SJS) and drug-induced hypersensitivity syndrome (HSS) limits the use of the anticonvulsant carbamazepine (CBZ). HLA-B*15:02 and HLA-A*31:01 have been identified as predictive genetic markers for CBZ hypersensitivity in Asian and European patients. To replicate these genetic associations in pediatric patients from North America with a diverse ethnic background, we investigated HLA-A*31:01 and HLA-B*15:02 in 42 children with CBZ hypersensitivity, and 91 CBZ-tolerant children from across Canada. HLA-A*31:01 was significantly associated with CBZ-HSS (odds ratio (OR): 26.4, p=0.0025) and maculopapular exanthems (OR: 8.6, p=0.0037), but not with CBZ-SJS. Conversely, HLA-B*15:02 was associated with CBZ-SJS (OR: 38.6, p=0.002), but not HSS and maculopapular exanthems. This study is the first to demonstrate the association of HLA-A*31:01 with CBZ hypersensitivity in children, providing important replication of this association and highlighting the importance of HLA-A*31:01 as a predictive biomarker across various ancestries. PMID:23588310
Superposed epoch analysis of ion temperatures during CME- and CIR/HSS-driven storms
NASA Astrophysics Data System (ADS)
Keesee, A. M.; Scime, E. E.
2012-12-01
The NASA Two Wide-angle Imaging Neutral atom Spectrometers (TWINS) Mission provides a global view of the magnetosphere with near-continuous coverage. Utilizing a novel technique to calculate ion temperatures from the TWINS energetic neutral atom (ENA) measurements, we generate ion temperature maps of the magnetosphere. These maps can be used to study ion temperature evolution during geomagnetic storms. A superposed epoch analysis of the ion temperature evolution during 48 storms will be presented. Zaniewski et al. [2006] performed a superposed epoch analysis of ion temperatures by storm interval using data from the MENA instrument on the IMAGE mission, demonstrating significant dayside ion heating during the main phase. The TWINS measurements provide more continuous coverage and improved spatial and temporal resolution. Denton and Borovsky [2008] noted differences in ion temperature evolution at geosynchronous orbit between coronal mass ejection (CME)- and corotating interaction region (CIR)/high speed stream (HSS)- driven storms. Using our global ion temperature maps, we have found consistent results for select individual storms [Keesee et al., 2012]. We will present superposed epoch analyses for the subgroups of CME- and CIR/HSS-driven storms to compare global ion temperature evolution during the two types of storms.
Effect of long-term fertilization on humic redox mediators in multiple microbial redox reactions.
Guo, Peng; Zhang, Chunfang; Wang, Yi; Yu, Xinwei; Zhang, Zhichao; Zhang, Dongdong
2018-03-01
This study investigated the effects of different long-term fertilizations on humic substances (HSs), humic acids (HAs) and humins, functioning as redox mediators for various microbial redox biotransformations, including 2,2',4,4',5,5'- hexachlorobiphenyl (PCB 153 ) dechlorination, dissimilatory iron reduction, and nitrate reduction, and their electron-mediating natures. The redox activity of HSs for various microbial redox metabolisms was substantially enhanced by long-term application of organic fertilizer (pig manure). As a redox mediator, only humin extracted from soils with organic fertilizer amendment (OF-HM) maintained microbial PCB 153 dechlorination activity (1.03 μM PCB 153 removal), and corresponding HA (OF-HA) most effectively enhanced iron reduction and nitrate reduction by Shewanella putrefaciens. Electrochemical analysis confirmed the enhancement of their electron transfer capacity and redox properties. Fourier transform infrared analysis showed that C=C and C=O bonds, and carboxylic or phenolic groups in HSs might be the redox functional groups affected by fertilization. This research enhances our understanding of the influence of anthropogenic fertility on the biogeochemical cycling of elements and in situ remediation ability in agroecosystems through microorganisms' metabolisms. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ali, Mubarak; Hamzah, Esah; Ali, Nouman
Titanium nitride (TiN) widely used as hard coating material was coated on tool steels, namely on high-speed steel (HSS) and D2 tool steel by physical vapor deposition method. The goal of this study was to examine the effect of ion etching with and without titanium (Ti) and chromium (Cr) on the adhesion strength of TiN coatings deposited on tool steels. From the scratch tester, it was observed that by increasing Ti ion etching showed an increase in adhesion strength of the deposited coatings. The coatings deposited with Cr ion etching showed poor adhesion compared with the coatings deposited with Ti ion etching. Scratch test measurements showed that the coating deposited with titanium ion etching for 16 min is the most stable coating and maintained even at the critical load of 66 N. The curve obtained via penetration depth along the scratch trace is linear in the case of HSS, whereas is slightly flexible in the case of D2 tool steel. The coatings deposited on HSS exhibit better adhesion compared with those on D2 tool steel.
Chemical Fingerprint Analysis and Quantitative Analysis of Rosa rugosa by UPLC-DAD.
Mansur, Sanawar; Abdulla, Rahima; Ayupbec, Amatjan; Aisa, Haji Akbar
2016-12-21
A method based on ultra performance liquid chromatography with a diode array detector (UPLC-DAD) was developed for quantitative analysis of five active compounds and chemical fingerprint analysis of Rosa rugosa . Ten batches of R. rugosa collected from different plantations in the Xinjiang region of China were used to establish the fingerprint. The feasibility and advantages of the used UPLC fingerprint were verified for its similarity evaluation by systematically comparing chromatograms with professional analytical software recommended by State Food and Drug Administration (SFDA) of China. In quantitative analysis, the five compounds showed good regression (R² = 0.9995) within the test ranges, and the recovery of the method was in the range of 94.2%-103.8%. The similarities of liquid chromatography fingerprints of 10 batches of R. rugosa were more than 0.981. The developed UPLC fingerprint method is simple, reliable, and validated for the quality control and identification of R. rugosa . Additionally, simultaneous quantification of five major bioactive ingredients in the R. rugosa samples was conducted to interpret the consistency of the quality test. The results indicated that the UPLC fingerprint, as a characteristic distinguishing method combining similarity evaluation and quantification analysis, can be successfully used to assess the quality and to identify the authenticity of R. rugosa .
Separation of natural product using columns packed with Fused-Core particles.
Yang, Peilin; Litwinski, George R; Pursch, Matthias; McCabe, Terry; Kuppannan, Krishna
2009-06-01
Three HPLC columns packed with 3 microm, sub-2 microm, and 2.7 microm Fused-Core (superficially porous) particles were compared in separation performance using two natural product mixtures containing 15 structurally related components. The Ascentis Express C18 column packed with Fused-Core particles showed an 18% increase in column efficiency (theoretical plates), a 76% increase in plate number per meter, a 65% enhancement in separation speed and a 19% increase in back pressure compared to the Atlantis T3 C18 column packed with 3 microm particles. Column lot-to-lot variability for critical pairs in the natural product mixture was observed with both columns, with the Atlantis T3 column exhibiting a higher degree of variability. The Ascentis Express column was also compared with the Acquity BEH column packed with sub-2 microm particles. Although the peak efficiencies obtained by the Ascentis Express column were only about 74% of those obtained by the Acquity BEH column, the 50% lower back pressure and comparable separation speed allowed high-efficiency and high-speed separation to be performed using conventional HPLC instrumentation.
Liu, Kuangyi; Song, Yonggui; Liu, Yali; Peng, Mi; Li, Hanyun; Li, Xueliang; Feng, Bingwei; Xu, Pengfei; Su, Dan
2017-05-30
Currently the pharmacokinetic (PK) research of herbal medicines is still limited and facing critical technical challenges on quantitative analysis of multi-components from biological matrices which often accompanied by lacking of authentic standards and low concentration. This present work contributes to the development of an integrated strategy for extensive pharmacokinetics assessments, and a selective and sensitive method independent of authentic standards for multi-components analysis based on the use of ultra-performance liquid chromatography/quadrupole-time-of-flight/MS E (UPLC-TOF-MS E ) and UPLC-TOF-MRM (rnhanced target). Initially, phytochemicals were identified by UPLC-TOF-MS E analysis, subsequently the identified components were matched with authentic standards and pre-classified, and UPLC-QTOF-MRM method optimized and developed. To guarantee reliable results, three rules are necessary: (1) detection with a mass error of less than 5ppm; (2) same class chemical compositions with structural high similarity between analytes with and without authentic reference substance; (3) a matching retention time between TOF-MRM mode and TOF-MS E within 0.2min. The developed and validated method was applied for the simultaneous determination of 12 lignans in rat plasma after administered with wine processed Schisandra Chinensis fructus (WPSCF) extract. Such an approach was found capable of providing extensive pharmacokinetic profiles of multi-components absorbed into blood after oral administrated with WPSCF extract. The results also indicated that significant difference in pharmacokinetics parameters of dibenzocyclooctadiene lignans was observed between schizandrin and gomisin compounds. For lignans, the absorption via gastrointestinal tract were all rapid and maintained relatively long retention time, especially for schisantherin A and schisantherin B with higher plasma exposure. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhao, Xia; Wang, Bo; Xie, Kaizhou; Liu, Jianyu; Zhang, Yangyang; Wang, Yajuan; Guo, Yawen; Zhang, Genxi; Dai, Guojun; Wang, Jinyu
2018-06-15
A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method and an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining eight coccidiostat (halofuginone, lasalocid, maduramicin, monensin, narasin, nigericin, robenidine and salinomycin) residues in beef were developed and compared. Samples were extracted with a mixture of acetic acid, acetonitrile and ethyl acetate and were then purified on a C 18 solid-phase extraction (SPE) column. The purified samples were analyzed by HPLC-MS/MS and UPLC-MS/MS, using 0.1% formic acid-water solution (A) and pure methanol (B) as the mobile phase. The samples were fractionated on a C 18 column using different gradient elution procedures, followed by qualitative analysis using a mass spectrometer operated in multiple reaction monitoring (MRM) mode with positive electrospray ionization; the external standard method was used for quantitation. At spiked levels that ranged from the limit of quantification (LOQ) to 100 μg/kg, the average recoveries were 71.96%-100.32% and 71.24%-89.24%, with relative standard deviations (RSDs) of 2.65%-12.38% and 2.98%-14.86% for UPLC-MS/MS and HPLC-MS/MS, respectively. The limits of detection (LODs) and LOQs of the eight coccidiostats were 0.14-0.32 μg/kg and 0.43-1.21 μg/kg, respectively, for UPLC-MS/MS analysis and 0.16-0.58 μg/kg and 0.53-1.92 μg/kg, respectively, for HPLC-MS/MS analysis. Both methods had good accuracy and precision, but UPLC-MS/MS had higher sensitivity than HPLC-MS/MS. Copyright © 2018 Elsevier B.V. All rights reserved.
Antihepatotoxic Effect and Metabolite Profiling of Panicum turgidum Extract via UPLC-qTOF-MS.
Farag, Mohamed A; El Fishawy, Ahlam M; El-Toumy, Sayed A; Amer, Khadiga F; Mansour, Ahmed M; Taha, Hala E
2016-07-01
Panicum turgidum , desert grass, has not reported any detailed phytochemical or biological study as yet. To establish P. turgidum secondary metabolite profile and to assess its antihepatotoxic effect. Ultra-performance liquid chromatography (UPLC) coupled to quadrupole high-resolution time of flight mass spectrometry (qTOF-MS) was used for large-scale secondary metabolites profiling in P. turgidum extract, alongside assessing median lethal dose (LD 50 ) and hepatoprotective effect against carbon tetrachloride (CCl 4 ) intoxication. A total of 39 metabolites were identified with flavonoids as the major class present as O/C -glycosides of luteolin, apigenin, isorhamnetin and naringenin, most of which are first time to be reported in Panicum sp. Antihepatotoxic effect of P. turgidum crude extract was revealed via improving several biochemical marker levels and mitigation against oxidative stress in the serum and liver tissues, compared with CCl4 intoxicated group and further confirmed by histopathological examination. This study reveals that P. turgidum , enriched in C -flavonoids, presents a novel source of safe antihepatotoxic agents and further demonstrates the efficacy of UPLC-MS metabolomics in the field of natural products drug discovery. UPLC coupled to qTOF-MS was used for large scale secondary metabolites profiling in P. turgidum .A total of 39 metabolites were identified with flavonoids amounting as the major metabolite class.Anti-hepatotoxic effect of P. turgidum extract was revealed via several biochemical markers and histopathological examination.This study reveals that P. turgidum , enriched in C -flavonoids, present a novel source of antihepatotoxic agents. Abbreviations used: UPLC: Ultra-performance liquid chromatography (UPLC), LD50: median lethal dose, MDA: malondialdehyde, GSH: glutathione reductase, CAT: catalase, SOD: superoxide dismutase, ALT: alanine aminotransferase, AST: aspartate aminotransferase, ALP: alkaline phosphatase, TG: triglycerides.
Antihepatotoxic Effect and Metabolite Profiling of Panicum turgidum Extract via UPLC-qTOF-MS
Farag, Mohamed A.; El Fishawy, Ahlam M.; El-Toumy, Sayed A.; Amer, Khadiga F.; Mansour, Ahmed M.; Taha, Hala E.
2016-01-01
Background: Panicum turgidum, desert grass, has not reported any detailed phytochemical or biological study as yet Objective: To establish P. turgidum secondary metabolite profile and to assess its antihepatotoxic effect Materials and Methods: Ultra-performance liquid chromatography (UPLC) coupled to quadrupole high-resolution time of flight mass spectrometry (qTOF-MS) was used for large-scale secondary metabolites profiling in P. turgidum extract, alongside assessing median lethal dose (LD50) and hepatoprotective effect against carbon tetrachloride (CCl4) intoxication Results: A total of 39 metabolites were identified with flavonoids as the major class present as O/C-glycosides of luteolin, apigenin, isorhamnetin and naringenin, most of which are first time to be reported in Panicum sp. Antihepatotoxic effect of P. turgidum crude extract was revealed via improving several biochemical marker levels and mitigation against oxidative stress in the serum and liver tissues, compared with CCl4 intoxicated group and further confirmed by histopathological examination. Conclusion: This study reveals that P. turgidum, enriched in C-flavonoids, presents a novel source of safe antihepatotoxic agents and further demonstrates the efficacy of UPLC-MS metabolomics in the field of natural products drug discovery. SUMMARY UPLC coupled to qTOF-MS was used for large scale secondary metabolites profiling in P. turgidum.A total of 39 metabolites were identified with flavonoids amounting as the major metabolite class.Anti-hepatotoxic effect of P. turgidum extract was revealed via several biochemical markers and histopathological examination.This study reveals that P. turgidum, enriched in C-flavonoids, present a novel source of antihepatotoxic agents. Abbreviations used: UPLC: Ultra-performance liquid chromatography (UPLC), LD50: median lethal dose, MDA: malondialdehyde, GSH: glutathione reductase, CAT: catalase, SOD: superoxide dismutase, ALT: alanine aminotransferase, AST: aspartate aminotransferase, ALP: alkaline phosphatase, TG: triglycerides. PMID:27761073
Reitzle, Lukas; Maier, Barbara; Stojanov, Silvia; Teupser, Daniel; Muntau, Ania C; Vogeser, Michael; Gersting, Søren W
2015-08-01
Mevalonate kinase deficiency, a rare autosomal recessive autoinflammatory disease, is caused by mutations in the MVK gene encoding mevalonate kinase (MK). MK catalyzes the phosphorylation of mevalonic acid to mevalonate-5-phosphate (MVAP) in the pathway of isoprenoid and sterol synthesis. The disease phenotype correlates with residual activity ranging from <0.5% for mevalonic aciduria to 1-7% for the milder hyperimmunoglobulinemia D and periodic fever syndrome (HIDS). Hence, assessment of loss-of-function requires high accuracy measurements. We describe a method using isotope dilution UPLC-MS/MS for precise and sensitive determination of MK activity. Wild-type MK and the variant V261A, which is associated with HIDS, were recombinantly expressed in Escherichia coli. Enzyme activity was determined by formation of MVAP over time quantified by isotope dilution UPLC-MS/MS. The method was validated according to the FDA Guidance for Bioanalytical Method Validation. Sensitivity for detection of MAVP by UPLC-MS/MS was improved by derivatization with butanol-HCl (LLOQ, 5.0 fmol) and the method was linear from 0.5 to 250 μmol/L (R(2) > 0.99) with a precision of ≥ 89% and an accuracy of ± 2.7%. The imprecision of the activity assay, including the enzymatic reaction and the UPLC-MS/MS quantification, was 8.3%. The variant V261A showed a significantly decreased activity of 53.1%. Accurate determination of MK activity was enabled by sensitive and reproducible detection of MVAP using UPLC-MS/MS. The novel method may improve molecular characterization of MVK mutations, provide robust genotype-phenotype correlations, and accelerate compound screening for drug candidates restoring variant MK activity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Dinç, Erdal; Ertekin, Zehra Ceren
2016-01-01
An application of parallel factor analysis (PARAFAC) and three-way partial least squares (3W-PLS1) regression models to ultra-performance liquid chromatography-photodiode array detection (UPLC-PDA) data with co-eluted peaks in the same wavelength and time regions was described for the multicomponent quantitation of hydrochlorothiazide (HCT) and olmesartan medoxomil (OLM) in tablets. Three-way dataset of HCT and OLM in their binary mixtures containing telmisartan (IS) as an internal standard was recorded with a UPLC-PDA instrument. Firstly, the PARAFAC algorithm was applied for the decomposition of three-way UPLC-PDA data into the chromatographic, spectral and concentration profiles to quantify the concerned compounds. Secondly, 3W-PLS1 approach was subjected to the decomposition of a tensor consisting of three-way UPLC-PDA data into a set of triads to build 3W-PLS1 regression for the analysis of the same compounds in samples. For the proposed three-way analysis methods in the regression and prediction steps, the applicability and validity of PARAFAC and 3W-PLS1 models were checked by analyzing the synthetic mixture samples, inter-day and intra-day samples, and standard addition samples containing HCT and OLM. Two different three-way analysis methods, PARAFAC and 3W-PLS1, were successfully applied to the quantitative estimation of the solid dosage form containing HCT and OLM. Regression and prediction results provided from three-way analysis were compared with those obtained by traditional UPLC method. Copyright © 2015 Elsevier B.V. All rights reserved.
Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS.
Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young
2015-11-09
In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry.
Chen, Lin-Wei; Wang, Qin; Qin, Kun-Ming; Wang, Xiao-Li; Wang, Bin; Chen, Dan-Ni; Cai, Bao-Chang; Cai, Ting
2016-02-01
The present study was designed to develop and validate a sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-QTOF/MS) method to separate and identify the chemical constituents of Qixue Shuangbu Tincture (QXSBT), a classic traditional Chinese medicine (TCM) prescription. Under the optimized UPLC and QTOF/MS conditions, 56 components in QXSBT, including chalcones, triterpenoids, protopanaxatriol, flavones and flavanones were identified and tentatively characterized within a running time of 42 min. The components were identified by comparing the retention times, accurate mass, and mass spectrometric fragmentation characteristic ions, and matching empirical molecular formula with that of the published compounds. In conclusion, the established UPLC-QTOF/MS method was reliable for a rapid identification of complicated components in the TCM prescriptions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.
Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS
Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young
2015-01-01
In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry. PMID:26569219
Yang, Yuan-Gui; Zhang, Ji; Zhao, Yan-Li; Zhang, Jin-Yu; Wang, Yuan-Zhong
2017-07-01
A rapid method was developed and validated by ultra-performance liquid chromatography-triple quadrupole mass spectroscopy with ultraviolet detection (UPLC-UV-MS) for simultaneous determination of paris saponin I, paris saponin II, paris saponin VI and paris saponin VII. Partial least squares discriminant analysis (PLS-DA) based on UPLC and Fourier transform infrared (FT-IR) spectroscopy was employed to evaluate Paris polyphylla var. yunnanensis (PPY) at different harvesting times. Quantitative determination implied that the various contents of bioactive compounds with different harvesting times may lead to different pharmacological effects; the average content of total saponins for PPY harvested at 8 years was higher than that from other samples. The PLS-DA of FT-IR spectra had a better performance than that of UPLC for discrimination of PPY from different harvesting times. Copyright © 2016 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Shaik, Firdoz; Zhang, Weiqing; Niu, Wenxin; Lu, Xianmao
2014-10-01
Ligand-free Au nanoparticles with controlled sizes are synthesized via a volume-confined method. In this synthesis, mesoporous hollow silica shells (mHSS) are used as nano-containers for the impregnation of HAuCl4 solution before they are separated from the bulk solution. With a simple heating process, the Au precursor confined within the cavity of the isolated hollow shells is converted into ligand-free Au nanoparticles. The size of the Au nanoparticles can be tuned precisely by loading HAuCl4 solution of different concentrations, or by using mHSS with different cavity volumes. The ligand-free Au nanoparticles demonstrate superior catalytic activity than sodium citrate-capped Au nanoparticles.
Dai, Sheng-Yun; Xu, Bing; Shi, Xin-Yuan; Xu, Xiang; Sun, Ying-Qiang; Qiao, Yan-Jiang
2017-03-01
This study is aimed to propose a continual improvement strategy based on quality by design (QbD). An ultra high performance liquid chromatography (UPLC) method was developed to accomplish the method transformation from HPLC to UPLC of Panax notogineng saponins (PNS) and achieve the continual improvement of PNS based on QbD, for example. Plackett-Burman screening design and Box-Behnken optimization design were employed to further understand the relationship between the critical method parameters (CMPs) and critical method attributes (CMAs). And then the Bayesian design space was built. The separation degree of the critical peaks (ginsenoside Rg₁ and ginsenoside Re) was over 2.0 and the analysis time was less than 17 min by a method chosen from the design space with 20% of the initial concentration of the acetonitrile, 10 min of the isocratic time and 6%•min⁻¹ of the gradient slope. At last, the optimum method was validated by accuracy profile. Based on the same analytical target profile (ATP), the comparison of HPLC and UPLC including chromatograph method, CMA identification, CMP-CMA model and system suitability test (SST) indicated that the UPLC method could shorten the analysis time, improve the critical separation and satisfy the requirement of the SST. In all, HPLC method could be replaced by UPLC for the quantity analysis of PNS. Copyright© by the Chinese Pharmaceutical Association.
Zang, Qing-Ce; Wang, Jia-Bo; Kong, Wei-Jun; Jin, Cheng; Ma, Zhi-Jie; Chen, Jing; Gong, Qian-Feng; Xiao, Xiao-He
2011-12-01
The fingerprints of artificial Calculus bovis extracts from different solvents were established by ultra-performance liquid chromatography (UPLC) and the anti-bacterial activities of artificial C. bovis extracts on Staphylococcus aureus (S. aureus) growth were studied by microcalorimetry. The UPLC fingerprints were evaluated using hierarchical clustering analysis. Some quantitative parameters obtained from the thermogenic curves of S. aureus growth affected by artificial C. bovis extracts were analyzed using principal component analysis. The spectrum-effect relationships between UPLC fingerprints and anti-bacterial activities were investigated using multi-linear regression analysis. The results showed that peak 1 (taurocholate sodium), peak 3 (unknown compound), peak 4 (cholic acid), and peak 6 (chenodeoxycholic acid) are more significant than the other peaks with the standard parameter estimate 0.453, -0.166, 0.749, 0.025, respectively. So, compounds cholic acid, taurocholate sodium, and chenodeoxycholic acid might be the major anti-bacterial components in artificial C. bovis. Altogether, this work provides a general model of the combination of UPLC chromatography and anti-bacterial effect to study the spectrum-effect relationships of artificial C. bovis extracts, which can be used to discover the main anti-bacterial components in artificial C. bovis or other Chinese herbal medicines with anti-bacterial effects. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yan, Xiaojing; Sun, Liangliang; Zhu, Guijie; Cox, Olivia F.; Dovichi, Norman J.
2016-01-01
A tryptic digest generated from Xenopus laevis fertilized embryos was fractionated by reversed phase liquid chromatography. One set of 30 fractions was analyzed by 100-min CZE-ESI-MS/MS separations (50 hr total instrument time), and a second set of 15 fractions was analyzed by 3-hr UPLC-ESI-MS/MS separations (45 hr total instrument time). CZE-MS/MS produced 70% as many protein IDs (4,134 vs. 5,787) and 60% as many peptide IDs (22,535 vs. 36,848) as UPLC-MS/MS with similar instrument time (50 h vs. 45 h) but with 50 times smaller total consumed sample amount (1.5 μg vs. 75 μg). Surprisingly, CZE generated peaks that were 25% more intense than UPLC for peptides that were identified by both techniques, despite the 50-fold lower loading amount; this high sensitivity reflects the efficient ionization produced by the electrokinetically-pumped nanospray interface used in CZE. This report is the first comparison of CZE-MS/MS and UPLC-MS/MS for large-scale eukaryotic proteomic analysis. The numbers of protein and peptide identifications produced by CZE-ESI-MS/MS approach those produced by UPLC-MS/MS, but with nearly two orders of magnitude lower sample amounts. PMID:27723263
Determination of anthelmintic drug residues in milk using UPLC-MS/MS with rapid polarity switching
USDA-ARS?s Scientific Manuscript database
A new UPLC-MS/MS (ultra-performance liquid chromatography coupled to tandem mass spectrometry) method was developed and validated to detect 38 anthelmintic drug residues, consisting of benzimidazoles, avermectins and flukicides. A modified QuEChERS-type extraction method was developed with an added...
Jacquet, Alain; Grolleau, Adeline; Jove, Jérémy; Lassalle, Régis; Moore, Nicholas
2015-02-01
To study the effect of a dietary supplement (TARGET 1®: a combination of casozepine, taurine, Eleutherococcus senticosus and extramel) on burnout symptomatology. A 12-week, double-blind, randomized, placebo-controlled trial was conducted in workers engaged in professional contact with patients, students or clients. All were affected by burnout syndrome based on a score of ≥4 on the Burnout Measure Scale (BMS-10). The primary outcome measure was the change in the BMS-10 score; secondary outcome measures included the change in the Maslach's Burnout Inventory scale-Human Service Survey (MBI-HSS) score and the Beck Depression Inventory. Five scores were evaluated. Eighty-seven participants were enrolled in the study: 44 received the active formulation (verum group); 43 received placebo. After 12 weeks' supplementation, the placebo group showed significant improvements in scores for BMS-10, MBI-HSS fatigue and the Beck Depression Inventory, but MBI-HSS depersonalization and task management were not improved; the verum group showed significant improvements in all five scores. The verum group consistently showed significantly greater improvements in scores than the placebo group. TARGET 1® significantly improved the symptoms of burnout after 12 weeks' use. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Stamatoyannopoulos, J A; Goodwin, A; Joyce, T; Lowrey, C H
1995-01-01
The beta-like globin genes require the upstream locus control region (LCR) for proper expression. The active elements of the LCR coincide with strong erythroid-specific DNase I-hypersensitive sites (HSs). We have used 5' HS4 as a model to study the formation of these HSs. Previously, we identified a 101 bp element that is required for the formation of this HS. This element binds six proteins in vitro. We now report a mutational analysis of the HS4 HS-forming element (HSFE). This analysis indicates that binding sites for the hematopoietic transcription factors NF-E2 and GATA-1 are required for the formation of the characteristic chromatin structure of the HS following stable transfection into murine erythroleukemia cells. Similarly arranged NF-E2 and GATA binding sites are present in the other HSs of the human LCR, as well as in the homologous mouse and goat sequences and the chicken beta-globin enhancer. A combination of DNase I and micrococcal nuclease sensitivity assays indicates that the characteristic erythroid-specific hypersensitivity of HS4 to DNase I is the result of tissue-specific alterations in both nucleosome positioning and tertiary DNA structure. Images PMID:7828582
Matejić, Bojana; Milenović, Miodrag; Kisić Tepavčević, Darija; Simić, Dušica; Pekmezović, Tatjana; Worley, Jody A.
2015-01-01
We report findings from a validation study of the translated and culturally adapted Serbian version of Maslach Burnout Inventory-Human Services Survey (MBI-HSS), for a sample of anesthesiologists working in the tertiary healthcare. The results showed the sufficient overall reliability (Cronbach's α = 0.72) of the scores (items 1–22). The results of Bartlett's test of sphericity (χ 2 = 1983.75, df = 231, p < 0.001) and Kaiser-Meyer-Olkin measure of sampling adequacy (0.866) provided solid justification for factor analysis. In order to increase sensitivity of this questionnaire, we performed unfitted factor analysis model (eigenvalue greater than 1) which enabled us to extract the most suitable factor structure for our study instrument. The exploratory factor analysis model revealed five factors with eigenvalues greater than 1.0, explaining 62.0% of cumulative variance. Velicer's MAP test has supported five-factor model with the smallest average squared correlation of 0,184. This study indicated that Serbian version of the MBI-HSS is a reliable and valid instrument to measure burnout among a population of anesthesiologists. Results confirmed strong psychometric characteristics of the study instrument, with recommendations for interpretation of two new factors that may be unique to the Serbian version of the MBI-HSS. PMID:26090517
NASA Astrophysics Data System (ADS)
Wu, Tianli; Pi, Mingyu; Wang, Xiaodeng; Guo, Weimeng; Zhang, Dingke; Chen, Shijian
2018-01-01
Exploring highly-efficient and low-cost non-noble metal electrocatalyst toward the hydrogen evolution reaction (HER) is highly desired for renewable energy system but remains challenging. In this work, three dimensional hierarchical porous cobalt poly-phosphide hollow spheres (CoP3 HSs) were prepared by topotactic phosphidation of the cobalt-based precursor via vacuum encapsulation technique. As a porous HER cathode, the CoP3 HSs delivers remarkable electrocatalytic performance over the wide pH range. It needs overpotentials of -69 mV and -118 mV with a small Tafel slope of 51 mV dec-1 to obtain current densities of 10 mA cm-2 and 50 mA cm-2, respectively, and maintains its electrocatalytic performance over 30 h in acidic solution. In addition, CoP3 also exhibit superior electrocatalytic performance and stability under neutral and alkaline conditions for the HER. Both experimental measurements and density functional theory (DFT) calculations are performed to explore the mechanism behind the excellent HER performance. The results of our study make the porous CoP3 HSs as a promising electrocatalyst for practical applications toward energy conversion system and present a new way for designing and fabricating HER electrodes through high degree of phosphorization and nano-porous architecture.
Expectations in patients with total knee arthroplasty.
Tekin, Burcu; Unver, Bayram; Karatosun, Vasfi
2012-01-01
The primary objective of total knee arthroplasty (TKA) is to decrease pain and restore functional knee joint. Current hypotheses indicate higher knee flexion is required in terms of life style, culture and expectations in Eastern communities. Therefore, society-specific features related to life style and cultural habits are needed. The objective of this study was to investigate the expectations of patients undergoing TKA. The study included 131 patients (18 male, 113 female; mean age: 66.2 ± 8.3 years) who underwent cemented TKA due to knee osteoarthritis. All patients were operated by the same surgeon using the same implant and surgical technique. Patients were evaluated using the Hospital for Special Surgery (HSS) knee score, a 15-item clinical knee assessment questionnaire and the HSS knee arthroplasty expectation questionnaire. Mean HSS score for the right knee was 89.2 ± 10.5 and for the left knee was 89.6 ± 9.4. The two most expected outcomes were improvements in pain (99.2%) and gait (96.2%) and the two least expected outcomes were improvements in psychological well-being (22.9%) and communicative skills (35.1%). Expectations were not affected by education and working conditions. Patients' most expected outcomes were improvement in pain and restoration of function (gait, climbing stairs and no need of assistive devices), similar to Western and American communities.
Matejić, Bojana; Milenović, Miodrag; Kisić Tepavčević, Darija; Simić, Dušica; Pekmezović, Tatjana; Worley, Jody A
2015-01-01
We report findings from a validation study of the translated and culturally adapted Serbian version of Maslach Burnout Inventory-Human Services Survey (MBI-HSS), for a sample of anesthesiologists working in the tertiary healthcare. The results showed the sufficient overall reliability (Cronbach's α = 0.72) of the scores (items 1-22). The results of Bartlett's test of sphericity (χ(2) = 1983.75, df = 231, p < 0.001) and Kaiser-Meyer-Olkin measure of sampling adequacy (0.866) provided solid justification for factor analysis. In order to increase sensitivity of this questionnaire, we performed unfitted factor analysis model (eigenvalue greater than 1) which enabled us to extract the most suitable factor structure for our study instrument. The exploratory factor analysis model revealed five factors with eigenvalues greater than 1.0, explaining 62.0% of cumulative variance. Velicer's MAP test has supported five-factor model with the smallest average squared correlation of 0,184. This study indicated that Serbian version of the MBI-HSS is a reliable and valid instrument to measure burnout among a population of anesthesiologists. Results confirmed strong psychometric characteristics of the study instrument, with recommendations for interpretation of two new factors that may be unique to the Serbian version of the MBI-HSS.
Martin, Natalia; Patel, Satyakam; Segre, Julia A.
2004-01-01
Mammalian epidermis provides a permeability barrier between an organism and its environment. Under homeostatic conditions, epidermal cells produce structural proteins, which are cross-linked in an orderly fashion to form a cornified envelope (CE). However, under genetic or environmental stress, specific genes are induced to rapidly build a temporary barrier. Small proline-rich (SPRR) proteins are the primary constituents of the CE. Under stress the entire family of 14 Sprr genes is upregulated. The Sprr genes are clustered within the larger epidermal differentiation complex on mouse chromosome 3, human chromosome 1q21. The clustering of the Sprr genes and their upregulation under stress suggest that these genes may be coordinately regulated. To identify enhancer elements that regulate this stress response activation of the Sprr locus, we utilized bioinformatic tools and classical biochemical dissection. Long-range comparative sequence analysis identified conserved noncoding sequences (CNSs). Clusters of epidermal-specific DNaseI-hypersensitive sites (HSs) mapped to specific CNSs. Increased prevalence of these HSs in barrier-deficient epidermis provides in vivo evidence of the regulation of the Sprr locus by these conserved sequences. Individual components of these HSs were cloned, and one was shown to have strong enhancer activity specific to conditions when the Sprr genes are coordinately upregulated. PMID:15574822
Investigation of wear land and rate of locally made HSS cutting tool
NASA Astrophysics Data System (ADS)
Afolalu, S. A.; Abioye, A. A.; Dirisu, J. O.; Okokpujie, I. P.; Ajayi, O. O.; Adetunji, O. R.
2018-04-01
Production technology and machining are inseparable with cutting operation playing important roles. Investigation of wear land and rate of cutting tool developed locally (C=0.56%) with an HSS cutting tool (C=0.65%) as a control was carried out. Wear rate test was carried out using Rotopol -V and Impact tester. The samples (12) of locally made cutting tools and one (1) sample of a control HSS cutting tool were weighed to get the initial weight and grit was fixed at a point for the sample to revolve at a specific time of 10 mins interval. Approach of macro transfer particles that involved mechanism of abrasion and adhesion which was termed as mechanical wear to handle abrasion adhesion processes was used in developing equation for growth wear at flank. It was observed from the wear test that best minimum wear rate of 1.09 × 10-8 and 2.053 × 10-8 for the tools developed and control were measured. MATLAB was used to simulate the wear land and rate under different conditions. Validated results of both the experimental and modeling showed that cutting speed has effect on wear rate while cutting time has predicted measure on wear land. Both experimental and modeling result showed best performances of tools developed over the control.
Stroe-Kunold, Esther; Buckert, Magdalena; Friederich, Hans-Christoph; Wesche, Daniela; Kopf, Stefan; Herzog, Wolfgang; Wild, Beate
2016-01-01
Leptin, a hormone secreted by adipose tissue, appears to play a major role in the homeostasis of body weight and psychobiological processes associated with anorexia nervosa (AN). However, there is scarce data on its exact influence on this disorder, in particular data over time. The present study addresses whether leptin changes during inpatient treatment play a role for treatment outcome and psychological factors in underweight AN patients. In order to understand whether leptin's role differs in relation to AN severity, data were assessed from 11 patients with a very low BMI and a higher chronicity (high severity group; HSS; mean BMI at the beginning of the study = 13.6; mean duration of illness = 5.1 years) vs. nine with less severe symptoms (LSS; mean BMI = 16.2; mean duration of illness = 3.7 years). During the course of treatment, serum leptin concentrations were assessed weekly while weight (BMI) was assessed twice per week. Concomitantly, psychological variables were obtained by means of electronic diaries. Unconditional linear growth models were calculated to evaluate the temporal course of leptin in relation to BMI. For HSS patients, two phases of treatment (BMI < 16 and BMI ≥ 16 kg/m2) were investigated. Leptin increased significantly with BMI in both groups of patients. For HSS patients, the increase of leptin in the first treatment phase did not predict later increases in BMI. Furthermore, the relationship of leptin and psychological factors was modulated by symptom severity. In HSS patients, higher leptin levels were associated with greater feelings of depression, anxiety, and stress whereas in LSS patients a higher leptin level showed the trend to be associated with lower psychological symptom burden. Our results suggest that leptin changes are differently associated with weight gain and psychological symptoms depending on the severity of starvation.
Lilian, Rivka R.; Railton, Jean; Schaftenaar, Erik; Mabitsi, Moyahabo; Grobbelaar, Cornelis J.; Khosa, N. Sellina; Maluleke, Babra H.; Struthers, Helen E.; McIntyre, James A.
2018-01-01
Visual impairment is a significant public health concern, particularly in low- and middle-income countries where eye care is predominantly provided at the primary healthcare (PHC) level, known as primary eye care. This study aimed to perform an evaluation of primary eye care services in three districts of South Africa and to assess whether an ophthalmic health system strengthening (HSS) package could improve these services. Baseline surveys were conducted in Cape Winelands District, Johannesburg Health District and Mopani District at 14, 25 and 36 PHC facilities, respectively. Thereafter, the HSS package, comprising group training, individual mentoring, stakeholder engagement and resource provision, was implemented in 20 intervention sites in Mopani District, with the remaining 16 Mopani facilities serving as control sites. At baseline, less than half the facilities in Johannesburg and Mopani had dedicated eye care personnel or sufficient space to measure visual acuity. Although visual acuity charts were available in most facilities, <50% assessed patients at the correct distance. Median score for availability of nine essential drugs was <70%. Referral criteria knowledge was highest in Cape Winelands and Johannesburg, with poor clinical knowledge across all districts. Several HSS interventions produced successful outcomes: compared to control sites there was a significant increase in the proportion of intervention sites with eye care personnel and resources such as visual acuity charts (p = 0.02 and <0.01, respectively). However, engaging with district pharmacists did not improve availability of essential drugs (p = 0.47). Referral criteria knowledge improved significantly in intervention sites (p<0.01) but there was no improvement in clinical knowledge (p = 0.76). Primary eye care in South Africa faces multiple challenges with regard to organisation of care, resource availability and clinical competence. The HSS package successfully improved some aspects of this care, but further development is warranted together with debate regarding the positioning of eye services at PHC level. PMID:29758069
Teixeira, Maria Glória; Costa, Maria C N; Souza, Luís P F; Nascimento, Estela M R; Barreto, Maurício L; Barbosa, Neusa; Carmo, Eduardo Hage
2012-07-01
To evaluate Brazil's public health surveillance system (HSS), identifying its core capacities, shortcomings, and limitations in dealing with public health emergencies, within the context of the International Health Regulations (IHR 2005). In 2008-2009 an evaluative cross-sectional study was conducted using semistructured questionnaires administered to key informants (municipal, state, and national government officials) to assess Brazilian HSS structure (legal framework and resources) and surveillance and response procedures vis-à-vis compliance with the IHR (2005) requirements for management of public health emergencies of national and international concern. Evaluation criteria included the capacity to detect, assess, notify, investigate, intervene, and communicate. Responses were analyzed separately by level of government (municipal health departments, state health departments, and national Ministry of Health). Overall, at all three levels of government, Brazil's HSS has a well-established legal framework (including the essential technical regulations) and the infrastructure, supplies, materials, and mechanisms required for liaison and coordination. However, there are still some weaknesses at the state level, especially in land border areas and small towns. Professionals in the field need to be more familiar with the IHR 2005 Annex 2 decision tool (designed to increase sensitivity and consistency in the notification process). At the state and municipal level, the capacity to detect, assess, and notify is better than the capacity to investigate, intervene, and communicate. Surveillance activities are conducted 24 hours a day, 7 days a week in 40.7% of states and 35.5% of municipalities. There are shortcomings in organizational activities and methods, and in the process of hiring and training personnel. In general, the core capacities of Brazil's HSS are well established and fulfill most of the requisites listed in the IHR 2005 with respect to both structure and surveillance and response procedures, particularly at the national and state levels.
Iyer, Hari S; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R; Drobac, Peter C
2015-01-01
While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level.
NASA Astrophysics Data System (ADS)
Tillmann, W.; Schaak, C.; Biermann, D.; Aßmuth, R.; Goeke, S.
2017-03-01
Cemented carbide (hard metal) cutting tools are the first choice to machine hard materials or to conduct high performance cutting processes. Main advantages of cemented carbide cutting tools are their high wear resistance (hardness) and good high temperature strength. In contrast, cemented carbide cutting tools are characterized by a low toughness and generate higher production costs, especially due to limited resources. Usually, cemented carbide cutting tools are produced by means of powder metallurgical processes. Compared to conventional manufacturing routes, these processes are more expensive and only a limited number of geometries can be realized. Furthermore, post-processing and preparing the cutting edges in order to achieve high performance tools is often required. In the present paper, an alternative method to substitute solid cemented carbide cutting tools is presented. Cutting tools made of conventional high speed steels (HSS) were coated with thick WC-Co (88/12) layers by means of thermal spraying (HVOF). The challenge is to obtain a dense, homogenous, and near-net-shape coating on the flanks and the cutting edge. For this purpose, different coating strategies were realized using an industrial robot. The coating properties were subsequently investigated. After this initial step, the surfaces of the cutting tools were ground and selected cutting edges were prepared by means of wet abrasive jet machining to achieve a smooth and round micro shape. Machining tests were conducted with these coated, ground and prepared cutting tools. The occurring wear phenomena were analyzed and compared to conventional HSS cutting tools. Overall, the results of the experiments proved that the coating withstands mechanical stresses during machining. In the conducted experiments, the coated cutting tools showed less wear than conventional HSS cutting tools. With respect to the initial wear resistance, additional benefits can be obtained by preparing the cutting edge by means of wet abrasive jet machining.
Iyer, Hari S.; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R.; Drobac, Peter C.
2015-01-01
Background While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. Design The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. Results We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Conclusions Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level. PMID:26140729
Hyman, Steve Alan; Shotwell, Matthew S; Michaels, Damon R; Han, Xue; Card, Elizabeth Borg; Morse, Jennifer L; Weinger, Matthew B
2017-12-01
Burnout affects all medical specialists, and concern about it has become common in today's health care environment. The gold standard of burnout measurement in health care professionals is the Maslach Burnout Inventory-Human Services Survey (MBI-HSS), which measures emotional exhaustion, depersonalization (DP), and personal accomplishment. Besides affecting work quality, burnout is thought to affect health problems, mental health issues, and substance use negatively, although confirmatory data are lacking. This study evaluates some of these effects. In 2011, the American Society of Anesthesiologists and the journal Anesthesiology cosponsored a webinar on burnout. As part of the webinar experience, we included access to a survey using MBI-HSS, 12-item Short Form Health Survey (SF-12), Social Support and Personal Coping (SSPC-14) survey, and substance use questions. Results were summarized using sample statistics, including mean, standard deviation, count, proportion, and 95% confidence intervals. Adjusted linear regression methods examined associations between burnout and substance use, SF-12, SSPC-14, and respondent demographics. Two hundred twenty-one respondents began the survey, and 170 (76.9%) completed all questions. There were 266 registrants total (31 registrants for the live webinar and 235 for the archive event), yielding an 83% response rate. Among respondents providing job titles, 206 (98.6%) were physicians and 2 (0.96%) were registered nurses. The frequency of high-risk responses ranged from 26% to 59% across the 3 MBI-HSS categories, but only about 15% had unfavorable scores in all 3. Mean mental composite score of the SF-12 was 1 standard deviation below normative values and was significantly associated with all MBI-HSS components. With SSPC-14, respondents scored better in work satisfaction and professional support than in personal support and workload. Males scored worse on DP and personal accomplishment and, relative to attending physicians, residents scored worse on DP. There was no significant association between MBI-HSS and substance use. Many anesthesiologists exhibit some high-risk burnout characteristics, and these are associated with lower mental health scores. Personal and professional support were associated with less emotional exhaustion, but overall burnout scores were associated with work satisfaction and professional support. Respondents were generally economically satisfied but also felt less in control at work and that their job kept them from friends and family. The association between burnout and substance use may not be as strong as previously believed. Additional work, perhaps with other survey instruments, is needed to confirm our results.
Objective is to develop analytical methods including SPE and UPLC/MS/MS needed to analyze over 60 human prescription pharamceuticals and metabolites belonging to a multitude of different classes in surface waters and wastewater effluent. The methods will be used in future studies...
Coumarins in horse chestnut flowers: isolation and quantification by UPLC method.
Dudek-Makuch, Marlena; Matławska, Irena
2013-01-01
The coumarins: scopoletin, esculetin and fraxetin were isolated from the flowers of horse chestnut (Aesculus hippocastanum L., Hippocastanaceae) and identified by spectrophotometric methods (UV, 1H, 13C NMR, ESI-MS). Their content, determined using the Ultra Performance Liquid Chromatography (UPLC), was 0.41, 0.13 and 0.05%, respectively.
USDA-ARS?s Scientific Manuscript database
A rapid UPLC method was developed for the simultaneous analysis of five indole alkaloids (harmalol, harmol, harmane, harmaline and harmine) and four flavonoids (orientin, isoorientin, vitexin, and isovitexin) from the aerial parts of Passiflora incarnata L. (Passifloracea), different species of Pass...
USDA-ARS?s Scientific Manuscript database
UPLC with UV detection was used for the quantification of alkaloids from roots of Hydrastis canadensis L. (goldenseal) and dietary supplements claiming to contain goldenseal. The chromatographic run time was less than 6 min. The detection wavelengths used were 290 and 344 nm for '-hydrastine, canadi...
Global metabolic profiling procedures for urine using UPLC-MS.
Want, Elizabeth J; Wilson, Ian D; Gika, Helen; Theodoridis, Georgios; Plumb, Robert S; Shockcor, John; Holmes, Elaine; Nicholson, Jeremy K
2010-06-01
The production of 'global' metabolite profiles involves measuring low molecular-weight metabolites (<1 kDa) in complex biofluids/tissues to study perturbations in response to physiological challenges, toxic insults or disease processes. Information-rich analytical platforms, such as mass spectrometry (MS), are needed. Here we describe the application of ultra-performance liquid chromatography-MS (UPLC-MS) to urinary metabolite profiling, including sample preparation, stability/storage and the selection of chromatographic conditions that balance metabolome coverage, chromatographic resolution and throughput. We discuss quality control and metabolite identification, as well as provide details of multivariate data analysis approaches for analyzing such MS data. Using this protocol, the analysis of a sample set in 96-well plate format, would take ca. 30 h, including 1 h for system setup, 1-2 h for sample preparation, 24 h for UPLC-MS analysis and 1-2 h for initial data processing. The use of UPLC-MS for metabolic profiling in this way is not faster than the conventional HPLC-based methods but, because of improved chromatographic performance, provides superior metabolome coverage.
Tang, Jin-Fa; Li, Wei-Xia; Zhang, Fan; Li, Yu-Hui; Cao, Ying-Jie; Zhao, Ya; Li, Xue-Lin; Ma, Zhi-Jie
2017-01-01
Nowadays, Radix Polygoni Multiflori (RPM, Heshouwu in Chinese) from different geographical origins were used in clinic. In order to characterize the chemical profiles of different geographical origins of RPM samples, ultra-high performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-QTOF/MS) combined with chemometrics (partial least squared discriminant analysis, PLS‑DA) method was applied in the present study. The chromatography, chemical composition and MS information of RPM samples from 18 geographical origins were acquired and profiled by UPLC-QTOF/MS. The chemical markers contributing the differentiation of RPM samples were observed and characterized by supervised PLS‑DA method of chemometrics. The chemical composition differences of RPM samples derived from 18 different geographical origins were observed. Nine chemical markers were tentatively identified which could be used as specific chemical markers for the differentiation of geographical RPM samples. UPLC-QTOF/MS method coupled with chemometrics analysis has potential to be used for discriminating different geographical TCMs. Results will help to develop strategies for conservation and utilization of RPM samples.
Park, Hee-Won; In, Gyo; Kim, Jeong-Han; Cho, Byung-Goo; Han, Gyeong-Ho; Chang, Il-Moo
2013-01-01
Discriminating between two herbal medicines (Panax ginseng and Panax quinquefolius), with similar chemical and physical properties but different therapeutic effects, is a very serious and difficult problem. Differentiation between two processed ginseng genera is even more difficult because the characteristics of their appearance are very similar. An ultraperformance liquid chromatography-quadrupole time-of-flight mass spectrometry (UPLC-QTOF MS)-based metabolomic technique was applied for the metabolite profiling of 40 processed P. ginseng and processed P. quinquefolius. Currently known biomarkers such as ginsenoside Rf and F11 have been used for the analysis using the UPLC-photodiode array detector. However, this method was not able to fully discriminate between the two processed ginseng genera. Thus, an optimized UPLC-QTOF-based metabolic profiling method was adapted for the analysis and evaluation of two processed ginseng genera. As a result, all known biomarkers were identified by the proposed metabolomics, and additional potential biomarkers were extracted from the huge amounts of global analysis data. Therefore, it is expected that such metabolomics techniques would be widely applied to the ginseng research field. PMID:24558312
Chen, Jian; Wu, Hong; Xu, Guo-Bing; Dai, Miao-Miao; Hu, Shun-Li; Sun, Liang-Liang; Wang, Wei; Wang, Rong; Li, Shu-Pin; Li, Guo-Qiang
2015-04-10
A specific, sensitive and high throughput ultra-high performance liquid chromatography-electrospray ionization tandem mass spectrometric method (UHPLC-ESI-MS/MS) was established and validated to assay geniposide (GE), a promising anti-inflammatory drug, in adjuvant arthritis rat plasma: application to pharmacokinetic and oral bioavailability studies and plasma protein binding ability. Plasma samples were processed by de-proteinised with ice-cold methanol and separated on an ACQUITY UPLC™ HSS C18 column (100 mm × 2.1mm i.d., 1.8 μm particle size) at a gradient flow rate of 0.2 mL/min using acetonitrile-0.1% formic acid in water as mobile phase, and the total run time was 9 min. Mass detection was performed in selected reaction monitoring (SRM) mode with negative electro-spray ionization includes the addition of paeoniflorin (Pae) as an internal standard (IS). The mass transition ion-pair was followed as m/z 387.4 → 122.4 for GE and m/z 479.4 → 449.0 for IS. The calibration curves were linear over the concentration range of 2-50,000 ng/mL with lower limit of quantification of 2 ng/mL. The intra-day and inter-day precisions (RSD, %) of the assay were less than 8.4%, and the accuracy was within ± 6.4% in terms of relative error (RE). Extraction recovery, matrix effect and stability were satisfactory in adjuvant arthritis rat plasma. The UHPLC-ESI-MS/MS method was successfully applied to a pharmacokinetic study of GE after oral administration of depurated GE at 33, 66, 132 mg/kg and intravenous injection at 33, 66, 132 mg/kg in adjuvant arthritis (AA) rats. In addition, it was found that GE has rapid absorption and elimination, low absolute bioavailability, high plasma protein binding ability in AA rats after oral administration within the tested dosage range. It suggested that GE showed slow distribution into the intra- and extracellular space, and the binding rate was not proportionally dependent on plasma concentration of GE when the concentration of GE was below 5.0 μg/mL. Copyright © 2015 Elsevier B.V. All rights reserved.
Alépée, N; Hibatallah, J; Klaric, M; Mewes, K R; Pfannenbecker, U; McNamee, P
2016-06-01
Cosmetics Europe recently established HPLC/UPLC-spectrophotometry as a suitable alternative endpoint detection system for measurement of formazan in the MTT-reduction assay of reconstructed human tissue test methods irrespective of the test system involved. This addressed a known limitation for such test methods that use optical density for measurement of formazan and may be incompatible for evaluation of strong MTT reducer and/or coloured chemicals. To build on the original project, Cosmetics Europe has undertaken a second study that focuses on evaluation of chemicals with functionalities relevant to cosmetic products. Such chemicals were primarily identified from the Scientific Committee on Consumer Safety (SCCS) 2010 memorandum (addendum) on the in vitro test EpiSkin™ for skin irritation testing. Fifty test items were evaluated in which both standard photometry and HPLC/UPLC-spectrophotometry were used for endpoint detection. The results obtained in this study: 1) provide further support for Within Laboratory Reproducibility of HPLC-UPLC-spectrophotometry for measurement of formazan; 2) demonstrate, through use a case study with Basazol C Blue pr. 8056, that HPLC/UPLC-spectrophotometry enables determination of an in vitro classification even when this is not possible using standard photometry and 3) addresses the question raised by SCCS in their 2010 memorandum (addendum) to consider an endpoint detection system not involving optical density quantification in in vitro reconstructed human epidermis skin irritation test methods. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhao, Xiangsheng; Wei, Jianhe; Yang, Meihua
2018-05-03
Morinda officinalis is an important herbal medicine and functional food, and its main constituents include anthraquinone and iridoid glycosides. Quantification of the main compounds is a necessary step to understand the quality and therapeutic properties of M. officinalis , but this has not yet been performed based on liquid chromatography/tandem mass spectrometry (LC-MS/MS). Analytes were extracted from M. officinalis by reflux method. Ultrahigh-performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UPLC-QqQ-MS) using multiple reaction monitoring (MRM) mode was applied for quantification. Fragmentation pathways of deacetyl asperulosidic acid and rubiadin were investigated based on UPLC with quadrupole time-of-flight tandem mass spectrometry (Q/TOF-MS) in the MS E centroid mode. The method showed a good linearity over a wide concentration range (R² ≥ 0.9930). The limits of quantification of six compounds ranged from 2.6 to 27.57 ng/mL. The intra- and inter-day precisions of the investigated components exhibited an RSD within 4.5% with mean recovery rates of 95.32⁻99.86%. Contents of selected compounds in M. officinalis varied significantly depending on region. The fragmentation pathway of deacetyl asperulosidic and rubiadin was proposed. A selective and sensitive method was developed for determining six target compounds in M. officinalis by UPLC-MS/MS. Furthermore, the proposed method will be helpful for quality control and identification main compounds of M. officinalis .
Global MHD simulations driven by idealized Alfvenic fluctuations in the solar wind
NASA Astrophysics Data System (ADS)
Claudepierre, S. G.
2017-12-01
High speed solar wind streams (HSSs) and corotating interaction regions (CIRs) often lead to MeV electron flux enhancements the Earth's outer radiation belt. The relevant physical processes responsible for these enhancements are not entirely understood. We investigate the potential role that solar wind Alfvenic fluctuations, intrinsic structures embedded in the HSS/CIRs, play in radiation belt dynamics. In particular, we explore the hypothesis that magnetospheric ultra-low frequency (ULF) pulsations driven by interplanetary magnetic field fluctuations are the intermediary mechanism responsible for the pronounced effect that HSS/CIRs have on the outer electron radiation belt. We examine these effects using global, three-dimensional magnetohydrodynamic (MHD) simulations driven by idealized interplanetary Alfvenic fluctuations, both monochromatic and broadband noise (Kolmogorov turbulence).
Medical Logistics Lessons Observed During Operations Enduring Freedom and Iraqi Freedom.
Dole, Mark J; Kissane, Jonathan M
2016-01-01
Medical Logistics (MEDLOG) is a function of the Army's integrated System for Health that provides the medical products and specialized logistics services required to deliver health protection and care under all operational conditions. In unified land operations, MEDLOG is an inherent function of Health Service Support (HSS), which also includes casualty care and medical evacuation. This paper focuses on a few key lessons observed during Operations Enduring Freedom and Iraqi Freedom with direct implications for the support of HSS in future operations as envisioned in the Army Operating Concept and the Joint Concept for Health Services. It also examines a few key enablers that helped mitigate these challenges that are not yet fully acknowledged in Army Medical Department doctrine, policy, and planning.
Hedaya, Mohsen A; Thomas, Vidhya; Abdel-Hamid, Mohamed E; Kehinde, Elijah O; Phillips, Oludotun A
2017-01-01
Linezolid is the first approved oxazolidinone antibacterial agent, whereas PH027 is a novel compound of the same class that exhibits good in vitro antibacterial activity. The objective of this study was to develop an UPLC-MS/MS assay for the analysis of linezolid and PH027 in plasma and to apply the method for comparative pharmacokinetic and tissue distribution studies of both compounds. Plasma samples and calibrators were extracted with diethyl ether after addition of the internal standard solution. After evaporation of the ether layer, the residue was reconstituted in mobile phase and injected into UPLC-MS/MS. The mobile phase consisted of 2mM ammonium acetate buffer solution and acetonitrile (70:30) at a flow rate of 0.2ml/min. Separation was achieved using UPLC BEH C 18 column, and quantitative determination of the analytes was performed using multiple-reaction monitoring (MRM) scanning mode. The method was validated by analyzing quality control tissue homogenate samples, and was applied to analyze tissue homogenate samples obtained following IV injections of linezolid and PH027 in rabbits. The developed UPLC-MS/MS method was linear in the concentration range of 50-5000ng/ml. Validation of the method proved that the method's precision, selectivity and stability were all within the acceptable limits. Linezolid and PH027 concentrations were accurately determined in the quality control tissue homogenate samples, and analysis of samples obtained following IV administration of the two compounds showed that the tissue to plasma concentration ratio of PH027 was higher than that of linezolid probably due to its higher lipophilicity. The developed UPLC-MS/MS method for the analysis of linezolid and PH027 in rabbit's plasma can accurately determine the concentrations of these compounds in different tissues. Copyright © 2016 Elsevier B.V. All rights reserved.
Kumar, Sunil; Singh, Awantika; Kumar, Brijesh; Singh, Bikarma; Bahadur, Lal; Lal, Mohan
2018-03-20
A rapid, sensitive and reproducible method using ultra-high-performance liquid chromatography coupled with electrospray ionization hybrid triple quadrupole-linear ion trap mass spectrometry (UHPLC-ESI-QqQ LIT -MS/MS) in multiple reaction monitoring (MRM) mode was developed and validated for simultaneous quantitation of anticancer (vincristine, vinblastine, vindesine), antihypertensive (ajmaline, ajmalicine, reserpine), aphrodisiac (yohimbine), sedative (serpentine) agents, dietary supplement (vinpocetine, yohimbine) and precursor of vinblastine (vindoline) from crude extracts of Catharanthus roseus. The precursor to product ion transitions for these compounds were observed at m/z 327 → 144, 355 → 144, 754 → 355, 353 → 144, 349 → 317, 825 → 225, 811 → 224, 458 → 188, 351 → 280 and 609 → 195, respectively in positive ionization mode. Chromatographic separation of all targeted TIAs was performed on ACQUITY UPLC BEH™ C 18 column (1.7 μm, 2.1 mm × 50 mm). The calibration curves were linear within the concentration range 0.5-1000 ng/mL and correlation coefficients (R 2 ) were closer to 1. Limit of detection (LOD) and limit of quantitation (LOQ) ranged from 0.039-0.583 ng/mL and 0.118-1.767 ng/mL, respectively. The intra-day (0.23-2.71% RSD) and inter-day (0.40-2.90% RSD) precision, stability (0.69-3.45% RSD) and recovery (99.63-104.30% ± %RSD ≤ 3.03%) were acceptable indicating good accuracy of the developed method. The method was successfully applied in ethanolic extracts of 39 samples of C. roseus parts (leaf, stem and root) collected from five different locations in India. Serpentine was detected as one of the most abundant TIA. Principal component analysis (PCA) was able to successfully discriminate among C. roseus samples on the basis of content of targeted TIAs. Copyright © 2017 Elsevier B.V. All rights reserved.
Kumar, Sunil; Singh, Awantika; Bajpai, Vikas; Srivastava, Mukesh; Singh, Bhim Pratap; Ojha, Sanjeev; Kumar, Brijesh
2016-09-01
Rauvolfia serpentina is an endangered plant species due to its over-exploitation. It has highly commercial and economic importance due to the presence of bioactive monoterpene indole alkaloids (MIAs) such as ajmaline, yohimbine, ajmalicine, serpentine and reserpine. To develop a validated, rapid, sensitive and selective ultra-high-performance liquid chromatography coupled with hybrid triple quadrupole-linear ion trap mass spectrometry (UHPLC-QqQLIT -MS/MS) method in the multiple reaction monitoring (MRM) mode for simultaneous determination of bioactive MIAs in ethanolic extract of seven Rauvolfia species and herbal formulations. The separation of MIAs was achieved on an ACQUITY UPLC BEH™ C18 column (1.7 μm, 2.1 mm × 50 mm) using a gradient mobile phase (0.1% aqueous formic acid and acetonitrile) at flow rate 0.3 μL/min in 7 min. The validated method showed good linearity (r(2) ≥ 0.9999), limit of detection (LOD) (0.06-0.15 ng/mL), limit of quantitation (LOQ) (0.18-0.44 ng/mL), precisions [intraday: relative standard deviation (RSD) ≤ 2.24%, interday: RSD ≤ 2.74%], stability (RSD ≤ 1.53%) and overall recovery (RSD ≤ 2.23%). The validated method was applied to quantitate MIAs. Root of Rauvolfia vomitoria showed a high content of ajmaline (48.43 mg/g), serpentine (87.77 mg/g) whereas high quantities of yohimbine (100.21 mg/g) and ajmalicine (120.51 mg/g) were detected in R. tetraphylla. High content of reserpine was detected in R. micrantha (35.18 mg/g) and R. serpentina (32.38 mg/g). The encouraging results of this study may lead to easy selection of suitable Rauvolfia species according to the abundance of MIAs. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Musteata, Florin Marcel; Sandoval, Manuel; Ruiz-Macedo, Juan C; Harrison, Kathleen; McKenna, Dennis; Millington, William
2016-08-24
Although solid phase microextraction (SPME) has been used extensively for fingerprinting volatile compounds emitted by plants, there are very few such reports for direct insertion SPME. In this research, direct contact of SPME probes with the interstitial fluid of plants was investigated as a method for phytochemical analysis. Medicinal plants from the Amazon have been the source of numerous drugs used in western medicine. However, a large number of species used in traditional medicine have not been characterized chemically, partly due to the difficulty of field work. In this project, the phytochemical composition of plants from several genera was fingerprinted by combining convenient field sampling by solid phase microextraction (SPME) with laboratory analysis by LC-MS. The new method was compared with classical sampling followed by liquid extraction (LE). SPME probes were prepared by coating stainless steel wires with a mixture of polyacrylonitrile and either RP-amide or HS-F5 silica particles. Sampling was performed by inserting the microextraction probes into various tissues of living plants in their natural environment. After in vivo extraction, the probes were sealed under vacuum and refrigerated until analyzed. The probes were desorbed in mobile phase and analyzed on a Waters Acquity UPLC with triple quadrupole mass spectrometer in positive ion mode. Twenty Amazonian plant species were sampled and unique metabolomic fingerprints were obtained. In addition, quantitative analysis was performed for previously identified compounds in three species. Comparison of the fingerprints obtained by in vivo SPME with those obtained by LE showed that 27% of the chromatographic features were unique to SPME, 57% were unique to LE, and 16% were common to both methods. In vivo SPME caused minimal damage to the plants, was much faster than traditional liquid extraction, and provided unique fingerprints for all investigated plants. SPME revealed unique chromatographic features, undetected by traditional extraction, although it produced only half as many peaks as ethanol extraction. Copyright © 2016 Elsevier B.V. All rights reserved.
Takach, Edward; O'Shea, Thomas; Liu, Hanlan
2014-08-01
Quantifying amino acids in biological matrices is typically performed using liquid chromatography (LC) coupled with fluorescent detection (FLD), requiring both derivatization and complete baseline separation of all amino acids. Due to its high specificity and sensitivity, the use of UPLC-MS/MS eliminates the derivatization step and allows for overlapping amino acid retention times thereby shortening the analysis time. Furthermore, combining UPLC-MS/MS with stable isotope labeling (e.g., isobaric tag for relative and absolute quantitation, i.e., iTRAQ) of amino acids enables quantitation while maintaining sensitivity, selectivity and speed of analysis. In this study, we report combining UPLC-MS/MS analysis with iTRAQ labeling of amino acids resulting in the elution and quantitation of 44 amino acids within 5 min demonstrating the speed and convenience of this assay over established approaches. This chromatographic analysis time represented a 5-fold improvement over the conventional HPLC-MS/MS method developed in our laboratory. In addition, the UPLC-MS/MS method demonstrated improvements in both specificity and sensitivity without loss of precision. In comparing UPLC-MS/MS and HPLC-MS/MS results of 32 detected amino acids, only 2 amino acids exhibited imprecision (RSD) >15% using UPLC-MS/MS, while 9 amino acids exhibited RSD >15% using HPLC-MS/MS. Evaluating intra- and inter-assay precision over 3 days, the quantitation range for 32 detected amino acids in rat plasma was 0.90-497 μM, with overall mean intra-day precision of less than 15% and mean inter-day precision of 12%. This UPLC-MS/MS assay was successfully implemented for the quantitative analysis of amino acids in rat and mouse plasma, along with mouse urine and tissue samples, resulting in the following concentration ranges: 0.98-431 μM in mouse plasma for 32 detected amino acids; 0.62-443 μM in rat plasma for 32 detected amino acids; 0.44-8590μM in mouse liver for 33 detected amino acids; 0.61-1241 μM in mouse kidney for 37 detected amino acids; and 1.39-1,681 μM in rat urine for 34 detected amino acids. The utility of the assay was further demonstrated by measuring and comparing plasma amino acid levels between pre-diabetic Zucker diabetic fatty rats (ZDF/Gmi fa/fa) and their lean littermates (ZDF/Gmi fa/?). Significant differences (P<0.001) in 9 amino acid concentrations were observed, with the majority ranging from a 2- to 5-fold increase in pre-diabetic ZDF rats on comparison with ZDF lean rats, consistent with previous literature reports. Copyright © 2014 Elsevier B.V. All rights reserved.
Zhao, Mingming; Li, Guofei; Qiu, Feng; Sun, Yaxin; Xu, Yinghong; Zhao, Limei
2016-04-01
Valproic acid (VPA), a widely used antiepileptic drug, has a narrow therapeutic range of 50-100 mcg/mL and shows large individual variability. It is very important to monitor the trough concentration of VPA using a reliable method. Therefore, the aim of this study was to develop and validate a rapid ultraperformance liquid chromatographic-mass spectrometry (UPLC-MS) method for quantification of VPA in human serum and to compare with fluorescence polarization immunoassay (FPIA), chemiluminescence microparticle immunoassay (CMIA), and high-performance liquid chromatography (HPLC) methods. The method included extraction of VPA in serum by deproteinization with acetonitrile. The analysis was performed using an EC-C18 column (2.7 μm, 4.6 × 50 mm) under isocratic conditions with a mobile phase of acetonitrile/water (containing 0.1% formic acid) (45/55, vol/vol) at a flow rate of 0.6 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer using an electrospary probe in the negative ionization mode. The method was validated by studies of selectivity, linearity, lower limit of quantification, accuracy, precision, recovery, matrix effect, and stability. Furthermore, all the 4 methods including FPIA, CMIA, and HPLC were subsequently used to assay the VPA concentration in 498 clinical serum samples collected from patients who received VPA. These methods were compared by Deming regression and Bland-Altman analysis. The retention time of VPA was 2.09 minutes. The calibration curve was linear over the concentration range of 1-200 mcg/mL, with a lower limit of quantification of 1 mcg/mL. The interday and intraday precision (RSD %) was less than 4.6% and 4.5%, respectively, and the accuracy (RE %) was below 7.9%. The recoveries and matrix effect of VPA at concentrations of 2, 50, and 160 mcg/mL met the requirement for the analysis of biological samples. No obvious degradation of VPA was observed under various storage conditions including room temperature for 12 hour, 3 freeze-thaw cycles, and -20°C for 3 months. Regression analysis showed that the correlation coefficients for the UPLC-MS versus FPIA, CMIA, and HPLC were 0.989, 0.988, and 0.987, respectively. The results of agreement tests between UPLC-MS and other methods showed that the mean difference of UPLC-MS and FPIA was -1.4 mcg/mL and 95% confidence interval of -7.7 to 4.9 mcg/mL, and the values for UPLC-MS and CMIA were -0.8 mcg/mL and -7.5 to 5.8 mcg/mL, for UPLC-MS and HPLC were 1.1 mcg/mL and -5.7 to 7.9 mcg/mL. The rapid UPLC-MS method we developed showed a good analytical performance required for therapeutic drug monitoring, leading to potential improvements in patient care and laboratory management. Compared with the FPIA, CMIA, and HPLC methods, the UPLC-MS method correlated well and displayed comparable VPA concentrations.
Rapid analysis of lignans from leaves of Podophyllum peltatum l. samples using UPLC-UV-MS
USDA-ARS?s Scientific Manuscript database
A new rapid UPLC-UV-MS method has been developed that permits the analysis of four lignans in P. peltatum L. Podophyllotoxin is a natural lignan that is being used as a precursor for the semi-synthetic anti-cancer drugs etoposide, teniposide and etopophos. The chromatographic separation was achieved...
USDA-ARS?s Scientific Manuscript database
A comparison study of analytical methods including HPLC, UPLC and HPTLC are presented in this paper for the determination of major alkaloid and triterpene saponins from the roots of Caulophyllum thalictroides (L.) Michx. (blue cohosh) and dietary supplements claiming to contain blue cohosh. The meth...
USDA-ARS?s Scientific Manuscript database
We developed a rapid method with ultra-performance liquid chromatography – tandem mass spectrometry (UPLC-MS/MS) for the qualitative and quantitative analysis of plant proanthocyanidins (PAs) directly from crude plant extracts. The method utilizes a range of cone voltages to achieve the depolymeriza...
Rapid analysis of lignans from leaves of Podophyllum peltatum L samples using UPLC-UV-MS
USDA-ARS?s Scientific Manuscript database
A new rapid UPLC-UV-MS method has been developed that permits the analysis of four lignans in P. peltatum L. Podophyllotoxin is a natural lignan that is being used as a precursor for the semi-synthetic anti-cancer drugs etoposide, teniposide and etopophos. The chromatographic separation was achieved...
USDA-ARS?s Scientific Manuscript database
In natural product chemistry, it is often crucial to determine sugar composition as well as the absolute configuration of each monosaccharide in glycosides. An ultra-performance liquid chromatography method using both photodiode array (PDA) and mass spectrometry detectors (UPLC-UV/MS) was developed....
USDA-ARS?s Scientific Manuscript database
A simple, fast UPLC-UV-MS method was developed for the determination of curcuminoids from roots of Curcuma longa L., Curcuma species (C. zedoaria, C. phaecaulis, C. wenyujin and C. kwangsiensis) and dietary supplements claiming to contain C. longa. The total content of curcuminoids (curcumin, desmet...
High precision mass measurements for wine metabolomics
Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis D.; Schmitt-Kopplin, Philippe
2014-01-01
An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS2. In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy. PMID:25431760
High precision mass measurements for wine metabolomics
NASA Astrophysics Data System (ADS)
Roullier-Gall, Chloé; Witting, Michael; Gougeon, Régis; Schmitt-Kopplin, Philippe
2014-11-01
An overview of the critical steps for the non-targeted Ultra-High Performance Liquid Chromatography coupled with Quadrupole Time-of-Flight Mass Spectrometry (UPLC-Q-ToF-MS) analysis of wine chemistry is given, ranging from the study design, data preprocessing and statistical analyses, to markers identification. UPLC-Q-ToF-MS data was enhanced by the alignment of exact mass data from FTICR-MS, and marker peaks were identified using UPLC-Q-ToF-MS². In combination with multivariate statistical tools and the annotation of peaks with metabolites from relevant databases, this analytical process provides a fine description of the chemical complexity of wines, as exemplified in the case of red (Pinot noir) and white (Chardonnay) wines from various geographic origins in Burgundy.
2013-01-01
Background The radix of Angelica sinensis is widely used as a medicinal herbal and metabolomics research of this plant during growth is necessary. Results Principal component analysis of the UPLC-QTOFMS data showed that these 27 samples could be separated into 4 different groups. The chemical markers accounting for these separations were identified from the PCA loadings plot. These markers were further verified by accurate mass tandem mass and retention times of available reference standards. The study has shown that accumulation of secondary metabolites of Angelica sinensis is closely related to the growth periods. Conclusions The UPLC-QTOFMS based metabolomics approach has great potential for analysis of the alterations of secondary metabolites of Angelica sinensis during growth. PMID:23453085
Crack propagation modelling for high strength steel welded structural details
NASA Astrophysics Data System (ADS)
Mecséri, B. J.; Kövesdi, B.
2017-05-01
Nowadays the barrier of applying HSS (High Strength Steel) material in bridge structures is their low fatigue strength related to yield strength. This paper focuses on the fatigue behaviour of a structural details (a gusset plate connection) made from NSS and HSS material, which is frequently used in bridges in Hungary. An experimental research program is carried out at the Budapest University of Technology and Economics to investigate the fatigue lifetime of this structural detail type through the same test specimens made from S235 and S420 steel grades. The main aim of the experimental research program is to study the differences in the crack propagation and the fatigue lifetime between normal and high strength steel structures. Based on the observed fatigue crack pattern the main direction and velocity of the crack propagation is determined. In parallel to the tests finite element model (FEM) are also developed, which model can handle the crack propagation. Using the measured strain data in the tests and the calculated values from the FE model, the approximation of the material parameters of the Paris law are calculated step-by-step, and their calculated values are evaluated. The same material properties are determined for NSS and also for HSS specimens as well, and the differences are discussed. In the current paper, the results of the experiments, the calculation method of the material parameters and the calculated values are introduced.
The effect of diltiazem on the manifestations of hyperthyroidism and thyroid function tests.
Keleştimur, F; Aksu, A
1996-01-01
The aim of this study is to evaluate the effect of diltiazem on the symptoms and signs of hyperthyroidism and thyroid function tests and to assess whether diltiazem can be used associated with an anti-thyroid drug, propylthiouracil. Twenty-two patients with hyperthyroidism were included in a prospective, randomized and placebo controlled study. Group 1 (n:12) patients received diltiazem, 60 mg twice a day, for 30 days. Group 2 (n:10) patients received placebo for 30 days. The patients in both groups were given propylthiouracil, 100 mg three times a day, for the last 20 days of the study period. The patients remained in the hospital during the first 10 days. A standardized hyperthyroid symptom score (HSS) and thyroid function tests including thyroid-stimulating hormone (TSH), free thyroxine (free T4), free triiodothyronine (free T3), total thyroxine (T4) and total triiodothyronine (T3) were evaluated before and after 10 and 30 days of the study period. HSS decreased from 27.80 +/- 4.54 to 22.51 +/- 4.04 after 10 days of diltiazem therapy in Group 1 (p < 0.01). But there was no change in HSS in Group 2 (p > 0.01). No significant changes in thyroid function tests have occurred in both groups after 10 days of treatment. Diltiazem can be used in patients with hyperthyroidism to alleviate adrenergic manifestations. It can also be safely combined with propylthiouracil.
Fabrication and characterization of a biodegradable Mg-2Zn-0.5Ca/1β-TCP composite.
Huang, Yan; Liu, Debao; Anguilano, Lorna; You, Chen; Chen, Minfang
2015-09-01
A biodegradable magnesium matrix and beta-tricalcium phosphate (β-TCP) particles reinforced composite Mg-2Zn-0.5Ca/1beta-TCP (wt.%) was fabricated for biomedical applications by the novel route of combined high shear solidification (HSS) and equal channel angular extrusion (ECAE). The as-cast composite obtained by HSS showed a fine and equiaxed grain structure with globally uniformly distributed β-TCP particles in aggregates of 2-25 μm in size. The ECAE processing at 300 °C resulted in further microstructural refinement and the improvement of β-TCP particle distribution. During ECAE, the β-TCP aggregates were broken into smaller ones or individual particles, forming a dispersion in the matrix. Such fabricated composite exhibited enhanced hardness and in vitro corrosion resistance. The enhanced hardness was attributed to both the addition of β-TCP particles and grain refinement while the development of a Ca-P rich surface layer from β-TCP during corrosion was responsible for the improvement in corrosion resistance. The composite was characterized in terms of microstructural evolution during fabrication, mechanical properties and electrochemical performance during polarization and immersion tests in a simulated body fluid. Discussions are made on the benefits of both HSS and ECAE and the mechanisms responsible for the enhanced corrosion resistance. Copyright © 2015 Elsevier B.V. All rights reserved.
Structural polymorphism at LCR and its role in beta-globin gene regulation.
Kukreti, Shrikant; Kaur, Harpreet; Kaushik, Mahima; Bansal, Aparna; Saxena, Sarika; Kaushik, Shikha; Kukreti, Ritushree
2010-09-01
Information on the secondary structures and conformational manifestations of eukaryotic DNA and their biological significance with reference to gene regulation and expression is limited. The human beta-globin gene Locus Control Region (LCR), a dominant regulator of globin gene expression, is a contiguous piece of DNA with five tissue-specific DNase I-hypersensitive sites (HSs). Since these HSs have a high density of transcription factor binding sites, structural interdependencies between HSs and different promoters may directly or indirectly regulate LCR functions. Mutations and SNPs may stabilize or destabilize the local secondary structures, affecting the gene expression by changes in the protein-DNA recognition patterns. Various palindromic or quasi-palindromic segments within LCR, could cause structural polymorphism and geometrical switching of DNA. This emphasizes the importance of understanding of the sequence-dependent variations of the DNA structure. Such structural motifs might act as regulatory elements. The local conformational variability of a DNA segment or action of a DNA specific protein is key to create and maintain active chromatin domains and affect transcription of various tissue specific beta-globin genes. We, summarize here the current status of beta-globin LCR structure and function. Further structural studies at molecular level and functional genomics might solve the regulatory puzzles that control the beta-globin gene locus. Copyright (c) 2010 Elsevier Masson SAS. All rights reserved.
Bender, M A; Byron, Rachel; Ragoczy, Tobias; Telling, Agnes; Bulger, Michael; Groudine, Mark
2006-08-15
The locus control region (LCR) was thought to be necessary and sufficient for establishing and maintaining an open beta-globin locus chromatin domain in the repressive environment of the developing erythrocyte. However, deletion of the LCR from the endogenous locus had no significant effect on chromatin structure and did not silence transcription. Thus, the cis-regulatory elements that confer the open domain remain unidentified. The conserved DNaseI hypersensitivity sites (HSs) HS-62.5 and 3'HS1 that flank the locus, and the region upstream of the LCR have been implicated in globin gene regulation. The flanking HSs bind CCCTC binding factor (CTCF) and are thought to interact with the LCR to form a "chromatin hub" involved in beta-globin gene activation. Hispanic thalassemia, a deletion of the LCR and 27 kb upstream, leads to heterochromatinization and silencing of the locus. Thus, the region upstream of the LCR deleted in Hispanic thalassemia (upstream Hispanic region [UHR]) may be required for expression. To determine the importance of the UHR and flanking HSs for beta-globin expression, we generated and analyzed mice with targeted deletions of these elements. We demonstrate deletion of these regions alone, and in combination, do not affect transcription, bringing into question current models for the regulation of the beta-globin locus.
Abouleish, Mohamed Y Z; Wells, Martha J M
2015-07-15
Humic substances (HSs) are precursors for the formation of hazardous disinfection by-products (DBPs) during chlorination of water. Various surrogate parameters have been used to investigate the generation of DBPs by HS precursors and the removal of these precursors by activated carbon treatment. Dissolved organic carbon (DOC)- and ultraviolet absorbance (UVA254)-based isotherms are commonly reported and presumed to be good predictors of the trihalomethane formation potential (THMFP). However, THMFP-based isotherms are rarely published such that the three types of parameters have not been compared directly. Batch equilibrium experiments on activated carbon were used to generate constant-initial-concentration sorption isotherms for well-characterized samples obtained from the International Humic Substances Society (IHSS). HSs representing type (fulvic acid [FA], humic acid [HA]), origin (aquatic, terrestrial), and geographical source (Nordic, Suwannee, Peat, Soil) were examined at pH6 and pH9. THMFP-based isotherms were generated and compared to determine if DOC- and UVA254-based isotherms were good predictors of the THMFP. The sorption process depended on the composition of the HSs and the chemical nature of the activated carbon, both of which were influenced by pH. Activated carbon removal of THM-precursors was pH- and HS-dependent. In some instances, the THMFP existed after UVA254 was depleted. Copyright © 2015 Elsevier B.V. All rights reserved.
Tanabe, Kazuhiro; Matsuo, Koji; Miyazawa, Masaki; Hayashi, Masaru; Ikeda, Masae; Shida, Masako; Hirasawa, Takeshi; Sho, Ryuichiro; Mikami, Mikio
2018-05-01
Serum levels of fully sialylated C4-binding protein (FS-C4BP) are remarkably elevated in patients with epithelial ovarian cancer (EOC) and can be used as a marker to distinguish ovarian clear cell carcinoma from endometrioma. This study aimed to develop a stable, robust and reliable liquid chromatography-hybrid mass spectrometry (UPLC-MS/MS) based diagnostic method that would generalize FS-C4BP as a clinical EOC biomarker. Glycopeptides derived from 20 μL of trypsin-digested serum glycoprotein were analyzed via UPLC equipped with an electrospray ionization time-of-flight mass spectrometer. This UPLC-MS/MS-based diagnostic method was optimized for FS-C4BP and validated using sera from 119 patients with EOC and 127 women without cancer. A1958 (C4BP peptide with two fully sialylated biantennary glycans) was selected as a marker of FS-C4BP because its level in serum was highest among FS-C4BP family members. Preparation and UPLC-MS/MS were optimized for A1958, and performance and robustness were significantly improved relative to our previous method. An area under the curve analysis of the FS-C4BP index receiver operating characteristic curve revealed that the ratio between A1958 and A1813 (C4BP peptide with two partially sialylated biantennary glycans) reached 85%. A combination of the FS-C4BP index and carbohydrate antigen-125 levels further enhanced the sensitivity and specificity. © 2017 The Authors. Biomedical Chromatography published by John Wiley & Sons Ltd.
Heo, Ji-Young; Kim, Suna; Kang, Jae-Hyun; Moon, Bokyung
2014-05-01
We aimed to identify the optimum conditions for the extraction of lutein from green tea using accelerated solvent extraction, and achieve improved analytical resolution and sensitivity between lutein and zeaxanthin using an ultra performance liquid chromatography (UPLC) system. The optimized method employed 80% ethanol as the extraction solvent, 160 °C as the temperature, 2 static cycles, and 5 min of static time. In the validation of the UPLC method, recovery was found to be in the range approximately 93.73 to 108.79%, with a correlation coefficient of 0.9974 and a relative standard deviation of <9.29% in inter- and intraday precision analyses. Finally, the lutein contents of green tea and green tea by-products were measured as 32.67 ± 0.70 and 18.18 ± 0.68 mg/100g dw, respectively. Furthermore, we verified that green tea by-products, which are discarded after producing green tea beverages, might be used as a great resource for massive lutein production. We have demonstrated that the common problem of inadequate resolution between lutein and zeaxanthin during carotenoid analyses can be overcome by optimizing the combined techniques of accelerated solvent extraction and ultra performance liquid chromatography (UPLC). UPLC was highly effective for saving time, solvent, and labor, as well as providing better resolution. The results in this study demonstrated that green tea by-products could be used as new sources for industrial lutein production owing to their massive production during the extraction of green tea beverages. © 2014 Institute of Food Technologists®
Li, Jie; Zhang, Ji; Zuo, Zhitian; Huang, Hengyu; Wang, Yuanzhong
2018-05-09
Background : Swertia nervosa (Wall. ex G. Don) C. B. Clarke, a promising traditional herbal medicine for the treatment of liver disorders, is endangered due to its extensive collection and unsustainable harvesting practices. Objective : The aim of this study is to discuss the diversity of metabolites (loganic acid, sweroside, swertiamarin, and gentiopicroside) at different growth stages and organs of Swertia nervosa using the ultra-high-performance LC (UPLC)/UV coupled with chemometric method. Methods : UPLC data, UV data, and data fusion were treated separately to find more useful information by partial least-squares discriminant analysis (PLS-DA). Hierarchical cluster analysis (HCA), an unsupervised method, was then employed for validating the results from PLS-DA. Results : Three strategies displayed different chemical information associated with the sample discrimination. UV information mainly contributed to the classification of different organs; UPLC information was prominently responsible for both organs and growth periods; the data fusion did not perform with apparent superiority compared with single data analysis, although it provided useful information to differentiate leaves that could not be recognized by UPLC. The quantification result showed that the content of swertiamarin was the highest compared with the other three metabolites, especially in leaves at the rooted stage (19.57 ± 5.34 mg/g). Therefore, we speculated that interactive transformations occurred among these four metabolites, facilitated by root formation. Conclusions : This work will contribute to exploitation of bioactive compounds of S. nervosa , as well as its large-scale propagation. Highlights : The roots formation may influence the distribution and accumulation of metabolites.
USDA-ARS?s Scientific Manuscript database
A novel, rapid and sensitive Ultra Performance Liquid-Chromatography tandem Mass-Spectrometry (UPLC-MS/MS) method for the simultaneous determination of several B-vitamins in human milk was developed. Resolution by retention time or multiple reaction monitoring (MRM) for thiamin, riboflavin, flavin a...
USDA-ARS?s Scientific Manuscript database
An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrophotometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. The instrumental detection limit based on signal-to-noise ratio (S/N) > 3, was below 1 pg/µL...
USDA-ARS?s Scientific Manuscript database
An analytical method was developed using ultra performance liquid chromatography-triple quadrupole-tandem mass spectrometry (UPLC-TQ-MS/MS) to simultaneously analyze 14 sulfonamides (SA) in six minutes. Despite the rapidity of the assay the system was properly re-equilibrated in this time. No carryo...
Kellogg, Joshua J; Graf, Tyler N; Paine, Mary F; McCune, Jeannine S; Kvalheim, Olav M; Oberlies, Nicholas H; Cech, Nadja B
2017-05-26
A challenge that must be addressed when conducting studies with complex natural products is how to evaluate their complexity and variability. Traditional methods of quantifying a single or a small range of metabolites may not capture the full chemical complexity of multiple samples. Different metabolomics approaches were evaluated to discern how they facilitated comparison of the chemical composition of commercial green tea [Camellia sinensis (L.) Kuntze] products, with the goal of capturing the variability of commercially used products and selecting representative products for in vitro or clinical evaluation. Three metabolomic-related methods-untargeted ultraperformance liquid chromatography-mass spectrometry (UPLC-MS), targeted UPLC-MS, and untargeted, quantitative 1 HNMR-were employed to characterize 34 commercially available green tea samples. Of these methods, untargeted UPLC-MS was most effective at discriminating between green tea, green tea supplement, and non-green-tea products. A method using reproduced correlation coefficients calculated from principal component analysis models was developed to quantitatively compare differences among samples. The obtained results demonstrated the utility of metabolomics employing UPLC-MS data for evaluating similarities and differences between complex botanical products.
Gao, Boyan; Qin, Fang; Ding, Tingting; Chen, Yineng; Lu, Weiying; Yu, Liangli Lucy
2014-08-13
Ultraperformance liquid chromatography mass spectrometry (UPLC-MS), flow injection mass spectrometry (FIMS), and headspace gas chromatography (headspace-GC) combined with multivariate data analysis techniques were examined and compared in differentiating organically grown oregano from that grown conventionally. It is the first time that headspace-GC fingerprinting technology is reported in differentiating organically and conventionally grown spice samples. The results also indicated that UPLC-MS, FIMS, and headspace-GC-FID fingerprints with OPLS-DA were able to effectively distinguish oreganos under different growing conditions, whereas with PCA, only FIMS fingerprint could differentiate the organically and conventionally grown oregano samples. UPLC fingerprinting provided detailed information about the chemical composition of oregano with a longer analysis time, whereas FIMS finished a sample analysis within 1 min. On the other hand, headspace GC-FID fingerprinting required no sample pretreatment, suggesting its potential as a high-throughput method in distinguishing organically and conventionally grown oregano samples. In addition, chemical components in oregano were identified by their molecular weight using QTOF-MS and headspace-GC-MS.
Zhao, Yu-Jiao; Xu, Wen-Hui; Shen, Xiao-Li; Tian, Jun-Sheng; Qin, Xue-Mei
2017-02-01
This research is to establish TLC and UPLC methods for simultaneous determination of 3 atractylenolides in Atractylodes macrocephala. Silica gel GF254 plate was used for identification of A. macrocephala, and UPLC-PDA gradient elution method was used to simultaneously determine atractylenolide Ⅰ, Ⅱ and Ⅲ. The Waters BEH C₁₈ column(2.1 mm×100 mm,1.7 μm)with acetonitrile-water as mobile phase and the wavelength of UV detector of 235 nm were performed. The quality control study showed that the characteristic for identification by TLC was distinct and highly specific. The method of content determination was in accordance with the regulations. The quantitative evaluation of atractylenolide Ⅰ,Ⅱ and Ⅲ was in good linear range(r>0.999 9), and the average recovery was 93.48%(RSD 1.4%),94.97%(RSD 1.6%),92.71%(RSD 1.2%),respectively. TLC identification was in good specificity and repeatability, and the UPLC-PDA method for the simultaneous determination of 3 atractylenolides was simple and reliable for the quality control of A.macrocephala. Copyright© by the Chinese Pharmaceutical Association.
Chen, Si; Li, Meihong; Zheng, Gongyu; Wang, Tingting; Lin, Jun; Wang, Shanshan; Wang, Xiaxia; Chao, Qianlin; Cao, Shixian; Yang, Zhenbiao; Yu, Xiaomin
2018-01-24
Wuyi Rock tea, well-recognized for rich flavor and long-lasting fragrance, is a premium subcategory of oolong tea mainly produced in Wuyi Mountain and nearby regions of China. The quality of tea is mainly determined by the chemical constituents in the tea leaves. However, this remains underexplored for Wuyi Rock tea cultivars. In this study, we investigated the leaf metabolite profiles of 14 major Wuyi Rock tea cultivars grown in the same producing region using UPLC-QTOF MS and UPLC-QqQ MS with data processing via principal component analysis and cluster analysis. Relative quantitation of 49 major metabolites including flavan-3-ols, proanthocyanidins, flavonol glycosides, flavone glycosides, flavonone glycosides, phenolic acid derivatives, hydrolysable tannins, alkaloids and amino acids revealed clear variations between tea cultivars. In particular, catechins, kaempferol and quercetin derivatives were key metabolites responsible for cultivar discrimination. Information on the varietal differences in the levels of bioactive/functional metabolites, such as methylated catechins, flavonol glycosides and theanine, offers valuable insights to further explore the nutritional values and sensory qualities of Wuyi Rock tea. It also provides potential markers for tea plant fingerprinting and cultivar identification.
Juin, Camille; Bonnet, Antoine; Nicolau, Elodie; Bérard, Jean-Baptiste; Devillers, Romain; Thiéry, Valérie; Cadoret, Jean-Paul; Picot, Laurent
2015-01-01
A fast and high-resolution UPLC-MSE analysis was used to identify phytoplankton pigments in an ethanol extract of Porphyridium purpureum (Pp) devoid of phycobiliproteins. In a first step, 22 standard pigments were analyzed by UPLC-MSE to build a database including retention time and accurate masses of parent and fragment ions. Using this database, seven pigments or derivatives previously reported in Pp were unequivocally identified: β,β-carotene, chlorophyll a, zeaxanthin, chlorophyllide a, pheophorbide a, pheophytin a, and cryptoxanthin. Minor amounts of Divinyl chlorophyll a, a chemotaxonomic pigment marker for prochlorophytes, were also unequivocally identified using the database. Additional analysis of ionization and fragmentation patterns indicated the presence of ions that could correspond to hydroxylated derivatives of chlorophyll a and pheophytin a, produced during the ethanolic extraction, as well as previously described galactosyldiacylglycerols, the thylakoid coenzyme plastoquinone, and gracilamide B, a molecule previously reported in the red seaweed Gracillaria asiatica. These data point to UPLC-MSE as an efficient technique to identify phytoplankton pigments for which standards are available, and demonstrate its major interest as a complementary method for the structural elucidation of ionizable marine molecules. PMID:25913708
Lee, Jae Won; Choi, Bo-Ram; Kim, Young-Chang; Choi, Doo Jin; Lee, Young-Seob; Kim, Geum-Soog; Baek, Nam-In; Kim, Seung-Yu; Lee, Dae Young
2017-12-04
The effective production and usage of ginsenosides, given their distinct pharmacological effects, are receiving increasing amounts of attention. As the ginsenosides content differs in different parts of Panax ginseng, we wanted to assess and compare the ginsenosides content in the ginseng roots, leave, stems, and berries. To extract the ginsenosides, 70% (v/v) methanol was used. The optimal ultra-performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QTOF/MS) method was used to profile various ginsenosides from the different parts of P. ginseng. The datasets were then subjected to multivariate analysis including principal component analysis (PCA) and hierarchical clustering analysis (HCA). A UPLC-QTOF/MS method with an in-house library was constructed to profile 58 ginsenosides. With this method, a total of 39 ginsenosides were successfully identified and quantified in the ginseng roots, leave, stem, and berries. PCA and HCA characterized the different ginsenosides compositions from the different parts. The quantitative ginsenoside contents were also characterized from each plant part. The results of this study indicate that the UPLC-QTOF/MS method can be an effective tool to characterize various ginsenosides from the different parts of P. ginseng.
[Fast identification of constituents of Lagotis brevituba by using UPLC-Q-TOF-MS/MS method].
Xie, Jing; Zhang, Li; Zeng, Jin-Xiang; Li, Min; Wang, Juan; Xie, Xiong-Xiong; Zhong, Guo-Yue; Luo, Guang-Ming; Yuan, Jin-Bin; Liang, Jian
2017-06-01
The chemical constituents of Lagotis brevituba were rapidly determined and analyzed by using ultra performance liquid chromatography tandem quadrupole time of flight mass spectrometry (UPLC-Q-TOF-MS/MS) method, providing material basis for the clinical application of L. brevituba. The separation was performed on UPLC YMC-Triart C₁₈ (2.1 mm×100 mm, 1.9 μm) column, with acetonitrile-water containing 0.2% formic acid as mobile phase for gradient elution. The flow rate was 0.4 mL•min-1 gradient elution and column temperature was 40 ℃, the injection volume was 2 μL. ESI ion source was used to ensure the data collected in a negative ion mode. The chemical components of L. brevituba were identified through retention time, exact relative molecular mass, cleavage fragments of MS/MS and reported data. The results showed that a total of 22 compounds were identified, including 11 flavones, 6 phenylethanoid glycosides, 1 iridoid glucosides, and 4 organic acid. The UPLC-Q-TOF-MS/MS method could fast identify the chemical components of L. brevituba, providing valuable information about L. brevituba for its clinical application. Copyright© by the Chinese Pharmaceutical Association.
2017-01-01
A challenge that must be addressed when conducting studies with complex natural products is how to evaluate their complexity and variability. Traditional methods of quantifying a single or a small range of metabolites may not capture the full chemical complexity of multiple samples. Different metabolomics approaches were evaluated to discern how they facilitated comparison of the chemical composition of commercial green tea [Camellia sinensis (L.) Kuntze] products, with the goal of capturing the variability of commercially used products and selecting representative products for in vitro or clinical evaluation. Three metabolomic-related methods—untargeted ultraperformance liquid chromatography–mass spectrometry (UPLC-MS), targeted UPLC-MS, and untargeted, quantitative 1HNMR—were employed to characterize 34 commercially available green tea samples. Of these methods, untargeted UPLC-MS was most effective at discriminating between green tea, green tea supplement, and non-green-tea products. A method using reproduced correlation coefficients calculated from principal component analysis models was developed to quantitatively compare differences among samples. The obtained results demonstrated the utility of metabolomics employing UPLC-MS data for evaluating similarities and differences between complex botanical products. PMID:28453261
Havener, Robin W; Liang, Yufeng; Brown, Lola; Yang, Li; Park, Jiwoong
2014-06-11
We report a systematic study of the optical conductivity of twisted bilayer graphene (tBLG) across a large energy range (1.2-5.6 eV) for various twist angles, combined with first-principles calculations. At previously unexplored high energies, our data show signatures of multiple van Hove singularities (vHSs) in the tBLG bands as well as the nonlinearity of the single layer graphene bands and their electron-hole asymmetry. Our data also suggest that excitonic effects play a vital role in the optical spectra of tBLG. Including electron-hole interactions in first-principles calculations is essential to reproduce the shape of the conductivity spectra, and we find evidence of coherent interactions between the states associated with the multiple vHSs in tBLG.
Renovation and Expansion of the Caspary Research Building. Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Grassia, V. L.
2004-02-07
Critical to the Hospital's rebuilding efforts have been its public partners at the federal, state, and local government levels who have made a major financial commitment to renovating the Hospital's research infrastructure. To date, the Hospital for Special Surgery (HSS) has been awarded a total of nearly $8.5 million to create and equip new, state-of-the-art laboratories for scientific investigations. The modernization of the Hospital's research facilities was jump-started in 1998 with a $950,000 seed grant from the National Institutes of Health (NIH) to renovate laboratories for immunology research in the Caspary Research Building. Coupled with a matching $5.5 million commitmentmore » from HSS, this infusion of NIH funding laid the groundwork for an overhaul of all of the Hospital's research space.« less
Developing Advanced Human Support Technologies for Planetary Exploration Missions
NASA Technical Reports Server (NTRS)
Berdich, Debra P.; Campbell, Paul D.; Jernigan, J. Mark
2004-01-01
The United States Vision for Space Exploration calls for sending robots and humans to explore the Earth's moon, the planet Mars, and beyond. The National Aeronautics and Space Administration (NASA) is developing a set of design reference missions that will provide further detail to these plans. Lunar missions are expected to provide a stepping stone, through operational research and evaluation, in developing the knowledge base necessary to send crews on long duration missions to Mars and other distant destinations. The NASA Exploration Systems Directorate (ExSD), in its program of bioastronautics research, manages the development of technologies that maintain human life, health, and performance in space. Using a system engineering process and risk management methods, ExSD's Human Support Systems (HSS) Program selects and performs research and technology development in several critical areas and transfers the results of its efforts to NASA exploration mission/systems development programs in the form of developed technologies and new knowledge about the capabilities and constraints of systems required to support human existence beyond Low Earth Orbit. HSS efforts include the areas of advanced environmental monitoring and control, extravehicular activity, food technologies, life support systems, space human factors engineering, and systems integration of all these elements. The HSS Program provides a structured set of deliverable products to meet the needs of exploration programs. These products reduce the gaps that exist in our knowledge of and capabilities for human support for long duration, remote space missions. They also reduce the performance gap between the efficiency of current space systems and the greater efficiency that must be achieved to make human planetary exploration missions economically and logistically feasible. In conducting this research and technology development program, it is necessary for HSS technologists and program managers to develop a common currency for decision making and the allocation of funding. A high level assessment is made of both the knowledge gaps and the system performance gaps across the program s technical project portfolio. This allows decision making that assures proper emphasis areas and provides a key measure of annual technological progress, as exploration mission plans continue to mature.
Howard, Michael D; Willis, Lisa; Wakarchuk, Warren; St Michael, Frank; Cox, Andrew; Horne, William T; Hontecillas, Raquel; Bassaganya-Riera, Josep; Lorenz, Eva; Inzana, Thomas J
2011-11-21
Histophilus somni is an etiologic agent of bovine respiratory and systemic diseases. Most pathogenic strains of H. somni that have been tested (36 of 42) are able to utilize N-acetyl-5-neuraminic acid (Neu5Ac) to sialylate their lipooligosaccharide (LOS). Homologs of all the genes required for transport, metabolism, and regulation of Neu5Ac in Haemophilus influenzae were identified in the sequenced genomes of H. somni. Three open reading frames (ORFs) in H. somni strain 2336 were identified that contained homology to genes required for LOS sialylation in related bacteria. ORF-1 (hssT-I), ORF-2 (hssT-II), and ORF-3 (neuA(Hs)) were predicted to encode for putative proteins with 37% amino acid homology to an α-(2-3)-sialyltransferase in H. influenzae, 43% amino acid homology to an Haemophilus ducreyi sialyltransferase, and 72% amino acid homology to an H. influenzae CMP-Neu5Ac synthetase, respectively. The specific enzyme activity of each ORF was determined using synthetic acceptor substrates. The HssT-I sialyltransferase primarily sialylated N-acetyllactosamine (LacNAc, Gal-β-[1-4]-GlcNAc-R), which is expressed on strain 2336, whereas HssT-II preferentially sialylated lacto-N-biose (LNB, Gal-β-[1-3]-GlcNAc-R), which is expressed on a phase variant of strain 2336: strain 738. Phase variation of the terminal galactose linkage in strain 738 from β-(1-3)-(LNB) to β-(1-4)-(LacNAc) was confirmed using monoclonal antibody reactivity and nuclear magnetic resonance spectroscopy. Sialylated LOS induced significantly less chemokine response from macrophages derived from Toll-like receptor (TLR)-4 knockout mice than from de-sialylated LOS. Furthermore, sialylated LOS induced significantly less NF-κB activity from mouse-derived bone marrow macrophages than de-sialylated LOS. Therefore, sialylation inhibited LOS signaling through TLR-4. In conclusion, H. somni utilizes linkage-specific sialyltransferases to sialylate its LOS to avoid innate host defense mechanisms despite simultaneous epitope phase variation. Copyright © 2011 Elsevier B.V. All rights reserved.
Fabricant, Peter D; Robles, Alex; Downey-Zayas, Timothy; Do, Huong T; Marx, Robert G; Widmann, Roger F; Green, Daniel W
2013-10-01
Having simple and reliable validated outcome measures is vital to conducting high-quality outcomes research in the field of orthopaedic surgery. Activity level is a key prognostic variable for patients with sports injuries. There is a paucity of such activity scales for children and adolescents who are otherwise healthy and athletically active. In addition to frequency and intensity of athletic activity, level of play and coach/trainer supervision are important variables unique to children and adolescents that are not captured in available adult scoring systems. To create and validate a concise and comprehensive activity rating scale for athletically active children and adolescents 10 to 18 years of age. Cohort study (diagnosis); Level of evidence, 2. Item generation was performed with a panel of orthopaedic surgeons and adolescent athletes. Item reduction, pilot testing and scale refinement resulted in a final 8-item instrument, the Hospital for Special Surgery Pediatric Functional Activity Brief Scale (HSS Pedi-FABS). Existing methods were used to determine reliability and validation. The Flesch-Kincaid score was calculated at a 6.6th-grade reading level (approximately 13 years old); therefore, although all subjects provided their own answers, parents were allowed to assist children younger than 13 years with reading the questionnaire. Scale reliability was excellent (test-retest reliability, intraclass correlation coefficient = 0.91; internal consistency, Cronbach alpha = .914), and there were no floor or ceiling effects. There was also robust construct validity: Convergent validity testing revealed positive correlations between the HSS Pedi-FABS and level of competition in athletic activity, number of reported hours of athletic activity per week, and existing comparable adult and pediatric scales. Discriminant validity was shown with age, body mass index, and type of sport as measured by the Daniel scale. The 8-item HSS Pedi-FABS can be used to reliably and accurately evaluate activity level as a prognostic variable for clinical research studies. It is a simple, reliable, and valid metric to assess activity in children and adolescents 10 to 18 years of age. This instrument will lead to better evaluation of posttreatment outcomes and patient-reported activity for child and adolescent athletes.
Wiklander, Maria; Rydström, Lise-Lott; Ygge, Britt-Marie; Navér, Lars; Wettergren, Lena; Eriksson, Lars E
2013-11-14
HIV is a stigmatizing medical condition. The concept of HIV stigma is multifaceted, with personalized stigma (perceived stigmatizing consequences of others knowing of their HIV status), disclosure concerns, negative self-image, and concerns with public attitudes described as core aspects of stigma for individuals with HIV infection. There is limited research on HIV stigma in children. The aim of this study was to test a short version of the 40-item HIV Stigma Scale (HSS-40), adapted for 8-18 years old children with HIV infection living in Sweden. A Swedish version of the HSS-40 was adapted for children by an expert panel and evaluated by think aloud interviews. A preliminary short version with twelve items covering the four dimensions of stigma in the HSS-40 was tested. The psychometric evaluation included inspection of missing values, principal component analysis (PCA), internal consistency, and correlations with measures of health-related quality of life (HRQoL). Fifty-eight children, representing 71% of all children with HIV infection in Sweden meeting the inclusion criteria, completed the 12-item questionnaire. Four items concerning participants' experiences of others' reactions to their HIV had unacceptable rates of missing values and were therefore excluded. The remaining items constituted an 8-item scale, the HIV Stigma Scale for Children (HSSC-8), measuring HIV-related disclosure concerns, negative self-image, and concerns with public attitudes. Evidence for internal validity was supported by a PCA, suggesting a three factor solution with all items loading on the same subscales as in the original HSS-40. The scale demonstrated acceptable internal consistency, with exception for the disclosure concerns subscale. Evidence for external validity was supported in correlational analyses with measures of HRQoL, where higher levels of stigma correlated with poorer HRQoL. The results suggest feasibility, reliability, as well as internal and external validity of the HSSC-8, an HIV stigma scale for children with HIV infection, measuring disclosure concerns, negative self-image, and concerns with public attitudes. The present study shows that different aspects of HIV stigma can be assessed among children with HIV in the age group 8-18.
El Fallah, Rawa; Rouillon, Régis; Vouvé, Florence
2018-06-15
The fate of benzo(a)pyrene (BaP), a ubiquitous contaminant reported to be persistent in the environment, is largely controlled by its interactions with the soil organic matter. In the present study, the spectral characteristics of fluorophores present in the physical fractions of the soil organic matter were investigated in the presence of pure BaP solution. After extraction of humic substances (HSs), and their fractionation into fluvic acid (FA) and humic acid (HA), two fluorescent compounds (C 1 and C 2 ) were identified and characterized in each physical soil fraction, by means of fluorescence excitation-emission matrices (FEEMs) and Parallel Factor Analysis (PARAFAC). Then, to each type of fraction having similar DOC content, was added an increasing volume of pure BaP solution in attempt to assess the behavior of BaP with the fluorophores present in each one. The application of FEEMs-PARAFAC method validated a three-component model that consisted of the two resulted fluorophores from HSs, FA and HA (C 1 and C 2 ) and a BaP-like fluorophore (C 3 ). Spectral modifications were noted for components C 2 HSs (C 2 in humic substances fraction) (λex/λem: 420/490-520 nm), C 2 FA (C 2 in fulvic acid fraction) (λex/λem: 400/487(517) nm) and C 1 HA (C 1 in humic acid fraction) (λex/λem: 350/452(520) nm). We explored the impact of increasing the volume of the added pure BaP solution on the scores of the fluorophores present in the soil fractions. It was found that the scores of C 2 HSs, C 2 FA, and C 1 HA increased when the volume of the added pure BaP solution increased. Superposition of the excitation spectra of these fluorophores with the emission spectrum of BaP showed significant overlaps that might explain the observed interactions between BaP and the fluorescent compounds present in SOM physical fractions. Copyright © 2018 Elsevier B.V. All rights reserved.
Developing Advanced Support Technologies for Planetary Exploration Missions
NASA Technical Reports Server (NTRS)
Berdich, Debra P.; Campbel, Paul D.; Jernigan, J. Mark
2004-01-01
The United States Vision for Space Exploration calls for sending robots and humans to explore the Earth s moon, the planet Mars, and beyond. The National Aeronautics and Space Administration (NASA) is developing a set of design reference missions that will provide further detail to these plans. Lunar missions are expected to provide a stepping stone, through operational research and evaluation, in developing the knowledge base necessary to send crews on long duration missions to Mars and other distant destinations. The NASA Exploration Systems Directorate (ExSD), in its program of bioastronautics research, manages the development of technologies that maintain human life, health, and performance in space. Using a systems engineering process and risk management methods, ExSD s Human Support Systems (HSS) Program selects and performs research and technology development in several critical areas and transfers the results of its efforts to NASA exploration mission/systems development programs in the form of developed technologies and new knowledge about the capabilities and constraints of systems required to support human existence beyond Low Earth Orbit. HSS efforts include the areas of advanced environmental monitoring and control, extravehicular activity, food technologies, life support systems, space human factors engineering, and systems integration of all these elements. The HSS Program provides a structured set of deliverable products to meet the needs of exploration programs. these products reduce the gaps that exist in our knowledge of and capabilities for human support for long duration, remote space missions. They also reduce the performance gap between the efficiency of current space systems and the greater efficiency that must be achieved to make human planetary exploration missions economically and logistically feasible. In conducting this research and technology development program, it is necessary for HSS technologists and program managers to develop a common currency for decision making and the allocation of funding. A high level assessment is made of both the knowledge gaps and the system performance gaps across the program s technical project portfolio. This allows decision making that assures proper emphasis areas and provides a key measure of annual technological progress, as exploration mission plans continue to mature.
NASA Astrophysics Data System (ADS)
El Fallah, Rawa; Rouillon, Régis; Vouvé, Florence
2018-06-01
The fate of benzo(a)pyrene (BaP), a ubiquitous contaminant reported to be persistent in the environment, is largely controlled by its interactions with the soil organic matter. In the present study, the spectral characteristics of fluorophores present in the physical fractions of the soil organic matter were investigated in the presence of pure BaP solution. After extraction of humic substances (HSs), and their fractionation into fluvic acid (FA) and humic acid (HA), two fluorescent compounds (C1 and C2) were identified and characterized in each physical soil fraction, by means of fluorescence excitation-emission matrices (FEEMs) and Parallel Factor Analysis (PARAFAC). Then, to each type of fraction having similar DOC content, was added an increasing volume of pure BaP solution in attempt to assess the behavior of BaP with the fluorophores present in each one. The application of FEEMs-PARAFAC method validated a three-component model that consisted of the two resulted fluorophores from HSs, FA and HA (C1 and C2) and a BaP-like fluorophore (C3). Spectral modifications were noted for components C2HSs (C2 in humic substances fraction) (λex/λem: 420/490-520 nm), C2FA (C2 in fulvic acid fraction) (λex/λem: 400/487(517) nm) and C1HA (C1 in humic acid fraction) (λex/λem: 350/452(520) nm). We explored the impact of increasing the volume of the added pure BaP solution on the scores of the fluorophores present in the soil fractions. It was found that the scores of C2HSs, C2FA, and C1HA increased when the volume of the added pure BaP solution increased. Superposition of the excitation spectra of these fluorophores with the emission spectrum of BaP showed significant overlaps that might explain the observed interactions between BaP and the fluorescent compounds present in SOM physical fractions.
Roncarolo, Federico; Boivin, Antoine; Denis, Jean-Louis; Hébert, Rejean; Lehoux, Pascale
2017-09-08
While there is an extensive literature on Health System (HS) strengthening and on the performance of specific HSs, there are few exhaustive syntheses of the challenges HSs are facing worldwide. This paper reports the findings of a scoping review aiming to classify the challenges of HSs investigated in the scientific literature. Specifically, it determines the kind of research conducted on HS challenges, where it was performed, in which health sectors and on which populations. It also identifies the types of challenge described the most and how they varied across countries. We searched 8 databases to identify scientific papers published in English, French and Italian between January 2000 and April 2016 that addressed HS needs and challenges. The challenges reported in the articles were classified using van Olmen et al.'s dynamic HS framework. Countries were classified using the Human Development Index (HDI). Our analyses relied on descriptive statistics and qualitative content analysis. 292 articles were included in our scoping review. 33.6% of these articles were empirical studies and 60.1% were specific to countries falling within the very high HDI category, in particular the United States. The most frequently researched sectors were mental health (41%), infectious diseases (12%) and primary care (11%). The most frequently studied target populations included elderly people (23%), people living in remote or poor areas (21%), visible or ethnic minorities (15%), and children and adolescents (15%). The most frequently reported challenges related to human resources (22%), leadership and governance (21%) and health service delivery (24%). While health service delivery challenges were more often examined in countries within the very high HDI category, human resources challenges attracted more attention within the low HDI category. This scoping review provides a quantitative description of the available evidence on HS challenges and a qualitative exploration of the dynamic relationships that HS components entertain. While health services research is increasingly concerned about the way HSs can adopt innovations, little is known about the system-level challenges that innovations should address in the first place. Within this perspective, four key lessons are drawn as well as three knowledge gaps.
Peixoto, Maria Paula Garofo; Kaiser, Samuel; Verza, Simone Gasparin; de Resende, Pedro Ernesto; Treter, Janine; Pavei, Cabral; Borré, Gustavo Luís; Ortega, George González
2012-01-01
Ilex paraguariensis A. St. Hil. (mate) is known in several South American countries because of the use of its leaves in stimulant herbal beverages. High saponin contents were reported in mate leaves and unripe fruits that possess a dissimilar composition. Two LC-UV methods previously reported for mate saponins assay focused on mate leaves and the quantification of the less polar saponin fraction in mate fruits. To develop and validate a LC-UV method to assay the total content of saponins in unripe mate fruits and characterise the chemical structure of triterpenic saponins by UPLC/Q-TOF-MS. From unripe fruits of mate a crude ethanolic extract was prepared (EX40) and the mate saponin fraction (MSF) purified by solid phase extraction. The LC-UV method was validated using ilexoside II as external standard. UPLC/Q-TOF-MS was adjusted from the LC-UV method to obtain the fragmentation patterns of the main saponins present in unripe fruits. Both LC-UV and UPLC/Q-TOF-MS methods indicate a wide range of Ilex saponins polarity. The ilexoside II and total saponin content of EX40 were 8.20% (w/w) and 47.60% (w/w), respectively. The total saponin content in unripe fruits was 7.28% (w/w). The saponins present in MSF characterised by UPLC/Q-TOF-MS are derived mainly from ursolic/oleanolic, acetyl ursolic or pomolic acid. The validated LC-UV method was shown to be linear, precise, accurate and to cover several saponins previously isolated from Ilex species and could be applied for the quality control of unripe fruit saponins. Copyright © 2011 John Wiley & Sons, Ltd.