Science.gov

Sample records for acs wide field

  1. Post-Flash Calibration Darks for the Advanced Camera for Surveys Wide Field Channel (ACS/WFC)

    NASA Astrophysics Data System (ADS)

    Ogaz, S.; Anderson, J.; Golimowski, D.

    2015-06-01

    We present a summary and analysis of the changes made to the ACS/WFC dark reference files. As of January 15, 2015 the ACS team has begun to produce post- flashed dark reference files for the Wide Field Channel (WFC). This change was made to combat the charge transfer efficiency (CTE) losses caused by radiation damage that the two WFC CCDs have suffered since being put into orbit by artificially increasing the background in the dark images. This has resulted in several changes to the reference file pipeline, and an improved calibration dark.

  2. AC electric field induced dielectrophoretic assembly behavior of gold nanoparticles in a wide frequency range

    NASA Astrophysics Data System (ADS)

    Liu, Weiyu; Wang, Chunhui; Ding, Haitao; Shao, Jinyou; Ding, Yucheng

    2016-05-01

    In this work, we focus on frequency-dependence of pearl chain formations (PCF) of gold nanoparticles driven by AC dielectrophoresis (DEP), especially in a low field-frequency range, where induced double-layer charging effect at ideally polarizable surfaces on particle DEP behavior and surrounding liquid motion need not be negligible. As field frequency varies, grown features of DEP assembly structures ranging from low-frequency non-bridged gap to high-frequency single gold nanoparticle-made nanowires bridging the electrodes are demonstrated experimentally. Specifically, at 10 kHz, a kind of novel channel-like structure with parallel opposing banks is formed at the center of interelectrode gap. In stark contrast, at 1 MHz, thin PCF with diameter of 100 nm is created along the shortest distance of the isolation spacing. Moreover, a particular conductive path of nanoparticle chains is produced at 1 MHz in a DEP device embedded with multiple floating electrodes. A theoretical framework taking into account field-induced double-layer polarization at both the particle/electrolyte and electrode/electrolyte interface is developed to correlate these experimental observations with induced-charge electrokinetic (ICEK) phenomenon. And a RC circuit model is helpful in accounting for the formation of this particular non-bridged channel-like structure induced by a low-frequency AC voltage. As compared to thin PCF formed at high field frequency that effectively short circuits the electrode pair, though it is difficult for complete PCF bridging to occur at low frequency, the non-bridged conducting microstructure has potential to further miniaturize the size of electrode gap fabricated by standard micromachining process and may find useful application in biochemical sensing.

  3. Refining the Search for Suitable KBOs: Calibration of the HST/ACS Wide Field Camera Ramp Filters.

    NASA Astrophysics Data System (ADS)

    Trafton, Laurence M.

    2014-11-01

    After the New Horizons flyby of Pluto, the spacecraft will travel on to fly by one or more KBO objects. These are yet to be determined; searches are currently underway to locate suitable candidates. Once some candidates are identified, further observations are likely in order to decide on the actual targets; e.g., spectra or narrow-band observations vs. rotational phase to determine the presence of frozen volatiles. With its wide field, clear and broad band B and I filters, and its suite of medium band filters (9% FWHM), the ACS WFC camera on board HST is useful for searches over the CCD wavelength range. Moreover, its suite of narrow band (2%) ramp filters, which are also distributed over this wavelength range, are potentially useful for identifying the signature of spectral features, such as solid methane bands, for KBOs as dim as V = +25. However, the transmission of these ramp filters is uncertain since it was never calibrated. We report the calibration of 9 ACS/WFC ramp filters at 15 selected central wavelengths. A comparison of the calibrated transmissions to the existing uncalibrated ramp filters is presented. Corrective flats have been submitted for insertion into the ACS data reduction pipeline.This program was supported through HST-AR-10981.01-A.

  4. AC photovoltaic module magnetic fields

    SciTech Connect

    Jennings, C.; Chang, G.J.; Reyes, A.B.; Whitaker, C.M.

    1997-12-31

    Implementation of alternating current (AC) photovoltaic (PV) modules, particularly for distributed applications such as PV rooftops and facades, may be slowed by public concern about electric and magnetic fields (EMF). This paper documents magnetic field measurements on an AC PV module, complementing EMF research on direct-current PV modules conducted by PG and E in 1993. Although not comprehensive, the PV EMF data indicate that 60 Hz magnetic fields (the EMF type of greatest public concern) from PV modules are comparable to, or significantly less than, those from household appliances. Given the present EMF research knowledge, AC PV module EMF may not merit considerable concern.

  5. Manipulating Flames with AC Electric Fields

    NASA Astrophysics Data System (ADS)

    Bishop, Kyle

    2013-11-01

    Time-oscillating electric fields applied to plasmas present in flames create steady flows of gas capable of shaping, directing, enhancing, or even extinguishing flames. Interestingly, electric winds induced by AC electric fields can be stronger that those due to static fields of comparable magnitude. Furthermore, unlike static fields, the electric force due to AC fields is localized near the surface of the flame. Consequently, the AC response depends only on the local field at the surface of the flame - not on the position of the electrodes used to generate the field. These results suggest that oscillating electric fields can be used to manipulate and control combustion processes at a distance. To characterize and explain these effects, we investigate a simple experimental system comprising a laminar methane-air flame positioned between two parallel-plate electrodes. We quantify both the electric and hydrodynamic response of the flame as a function of frequency and magnitude of the applied field. A theoretical model shows how steady gas flows emerge from the time-averaged electrical force due to the field-induced motion of ions generated within the flame and by their disappearance by recombination. These results provide useful insights into the application of AC fields to direct combustion processes.

  6. Wide-Field Plate Database

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M. K.; Stavrev, K. Y.; Tsvetkova, K. P.; Semkov, E. H.; Mutatov, A. S.

    The Wide-Field Plate Database (WFPDB) and the possibilities for its application as a research tool in observational astronomy are presented. Currently the WFPDB comprises the descriptive data for 400 000 archival wide field photographic plates obtained with 77 instruments, from a total of 1 850 000 photographs stored in 269 astronomical archives all over the world since the end of last century. The WFPDB is already accessible for the astronomical community, now only in batch mode through user requests sent by e-mail. We are working on on-line interactive access to the data via INTERNET from Sofia and parallel from the Centre de Donnees Astronomiques de Strasbourg. (Initial information can be found on World Wide Web homepage URL http://www.wfpa.acad.bg.) The WFPDB may be useful in studies of a variety of astronomical objects and phenomena, andespecially for long-term investigations of variable objects and for multi-wavelength research. We have analysed the data in the WFPDB in order to derive the overall characteristics of the totality of wide-field observations, such as the sky coverage, the distributions by observation time and date, by spectral band, and by object type. We have also examined the totality of wide-field observations from point of view of their quality, availability and digitisation. The usefulness of the WFPDB is demonstrated by the results of identification and investigation of the photometrical behaviour of optical analogues of gamma-ray bursts.

  7. Wide field of view telescope

    DOEpatents

    Ackermann, Mark R.; McGraw, John T.; Zimmer, Peter C.

    2008-01-15

    A wide field of view telescope having two concave and two convex reflective surfaces, each with an aspheric surface contour, has a flat focal plane array. Each of the primary, secondary, tertiary, and quaternary reflective surfaces are rotationally symmetric about the optical axis. The combination of the reflective surfaces results in a wide field of view in the range of approximately 3.8.degree. to approximately 6.5.degree.. The length of the telescope along the optical axis is approximately equal to or less than the diameter of the largest of the reflective surfaces.

  8. Wide Field Imager for Athena

    NASA Astrophysics Data System (ADS)

    Meidinger, Norbert; Nandra, Kirpal; Rau, Arne; Plattner, Markus; WFI proto-Consortium

    2015-09-01

    The Wide Field Imager focal plane instrument on ATHENA will combine unprecedented survey power through its large field of view of 40 arcmin with a high count-rate capability (> 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.1 keV to 15 keV. At energy of 6 keV for example, the full width at half maximum of the line shall be not worse than 150 eV until the end of the mission. The performance is accomplished by a set of DEPFET active pixel sensor matrices with a pixel size well suited to the angular resolution of 5 arc sec (on-axis) of the mirror system.Each DEPFET pixel is a combined detector-amplifier structure with a MOSFET integrated onto a fully depleted 450 micron thick silicon bulk. Two different types of DEPFET sensors are planned for the WFI instrument: A set of large-area sensors to cover the physical size of 14 cm x 14 cm in the focal plane and a single gateable DEPFET sensor matrix optimized for the high count rate capability of the instrument. An overview will be given about the presently developed instrument concept and design, the status of the technology development, and the expected performance. An outline of the project organization, the model philosophy as well as the schedule will complete the presentation about the Wide Field Imager for Athena.

  9. Wide Field Instrument Adjutant Scientist

    NASA Astrophysics Data System (ADS)

    Spergel, David

    As Wide Field Instrument Adjutant Scientist, my goal will be to maximize the science capability of the mission in a cost-contained environment. I hope to work with the HQ, project and the FSWG to assure mission success. I plan to play a leadership role in communicating the WFIRST science capabilities to the astronomy community , obtain input from both science teams and the broader community that help derive performance requirements and calibration metrics. I plan to focus on developing the observing program for the deep fields and focus on using them to calibrate instrument performance and capabilities. I plan to organize workshops that will bring together WFIRST team members with astronomers working on LSST, Euclid, JWST, and the ELTs to maximize combined science return. I am also eager to explore the astrometric and stellar seismology capabilities of the instrument with a goal of maximizing science return without affecting science requirements.

  10. ROSAT wide field camera mirrors.

    PubMed

    Willingale, R

    1988-04-15

    The ROSAT wide field camera (WFC) is an XUV telescope operating in the 12-250-eV energy band. The mirror system utilizes Wolter-Schwarzschild type I (WS I) grazing incidence optics with a focal length of 525 mm, comprised of three nested aluminum shells with an outermost diameter of 576 mm providing a geometric aperture area of 456 cm(2). The reflecting surfaces are electroless nickel plated and coated with gold to enhance their reflectivity in the XUV. The mirrors have undergone full aperture optical testing, narrow beam XUV testing, and full aperture XUV testing. Measurements of the reflectivity are compared to theoretical values derived from the optical constants of gold in the XUV range. Analysis of the focused distribution is used to estimate the surface roughness and figuring errors of the polished surfaces. The results are compared to the mechanical metrology data collected during manufacture of the shells and the power spectral density of the reflecting surfaces is found to have a power-law form. PMID:20531591

  11. Development and application of setup for ac magnetic field in neutron scattering experiments.

    PubMed

    Klimko, Sergey; Zhernenkov, Kirill; Toperverg, Boris P; Zabel, Hartmut

    2010-10-01

    We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm(3) and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed. PMID:21034083

  12. Development and application of setup for ac magnetic field in neutron scattering experiments

    SciTech Connect

    Klimko, Sergey; Zhernenkov, Kirill; Toperverg, Boris P.; Zabel, Hartmut

    2010-10-15

    We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm{sup 3} and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed.

  13. A wide-frequency range AC magnetometer to measure the specific absorption rate in nanoparticles for magnetic hyperthermia

    NASA Astrophysics Data System (ADS)

    Garaio, E.; Collantes, J. M.; Garcia, J. A.; Plazaola, F.; Mornet, S.; Couillaud, F.; Sandre, O.

    2014-11-01

    Measurement of specific absorption rate (SAR) of magnetic nanoparticles is crucial to assert their potential for magnetic hyperthermia. To perform this task, calorimetric methods are widely used. However, those methods are not very accurate and are difficult to standardize. In this paper, we present AC magnetometry results performed with a lab-made magnetometer that is able to obtain dynamic hysteresis-loops in the AC magnetic field frequency range from 50 kHz to 1 MHz and intensities up to 24 kA m-1. In this work, SAR values of maghemite nanoparticles dispersed in water are measured by AC magnetometry. The so-obtained values are compared with the SAR measured by calorimetric methods. Both measurements, by calorimetry and magnetometry, are in good agreement. Therefore, the presented AC magnetometer is a suitable way to obtain SAR values of magnetic nanoparticles.

  14. The wide field/planetary camera

    NASA Technical Reports Server (NTRS)

    Westphal, J. A.; Baum, W. A.; Code, A. D.; Currie, D. G.; Danielson, G. E.; Gunn, J. E.; Kelsall, T. F.; Kristian, J. A.; Lynds, C. R.; Seidelmann, P. K.

    1982-01-01

    A wide site of potential astronomical and solar system scientific studies using the wide field planetary camera on space telescope are described. The expected performance of the camera as it approaches final assembly and testing is also detailed.

  15. Stereoscopic wide field of view imaging system

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F. (Inventor); Sedwick, Raymond J. (Inventor); Jonas, Eric M. (Inventor)

    2011-01-01

    A stereoscopic imaging system incorporates a plurality of imaging devices or cameras to generate a high resolution, wide field of view image database from which images can be combined in real time to provide wide field of view or panoramic or omni-directional still or video images.

  16. Absorption of ac fields in amorphous indium-oxide films

    NASA Astrophysics Data System (ADS)

    Ovadyahu, Z.

    2014-08-01

    Absorption data from applied ac fields in Anderson-localized amorphous indium-oxide (InxO) films are shown to be frequency and disorder dependent. The absorption shows a roll-off at a frequency which is much lower than the electron-electron scattering rate of the material when it is in the diffusive regime. This is interpreted as evidence for discreteness of the energy spectrum of the deeply localized regime. This is consistent with recent many-body localization scenarios. As the metal-insulator transition is approached, the absorption shifts to higher frequencies. Comparing with the previously obtained results on the crystalline version of indium-oxide (In2O3-x) implies a considerably higher inelastic electron-phonon scattering rate in the amorphous material. The range over which the absorption versus frequency decreases may indicate that a wide distribution of localization length is a common feature in these systems.

  17. IOT Overview: Wide-Field Imaging

    NASA Astrophysics Data System (ADS)

    Selman, F. J.

    The Wide Field Imager (WFI) instrument at La Silla has been the workhorse of wide-field imaging instruments at ESO for several years. In this contribution I will summarize the issues relating to its productivity for the community both in terms of the quality and quantity of data that has come out of it. Although only surveys of limited scope have been completed using WFI, it is ESO's stepping-stone to the new generation of survey telescopes.

  18. Critical field measurements in superconductors using ac inductive techniques

    NASA Astrophysics Data System (ADS)

    Campbell, S. A.; Ketterson, J. B.; Crabtree, G. W.

    1983-09-01

    The ac in-phase and out-of-phase response of type II superconductors is discussed in terms of dc magnetization curves. Hysteresis in the dc magnetization is shown to lead to a dependence of the ac response on the rate at which an external field is swept. This effect allows both Hc1 and Hc2 to be measured by ac techniques. A relatively simple mutual inductance bridge for making such measurements is described in the text, and factors affecting bridge sensitivity are discussed in the Appendix. Data for the magnetic superconductor ErRh4B4 obtained using this bridge are reported.

  19. Wide field corrector for the KMTNet telescope

    NASA Astrophysics Data System (ADS)

    Lee, Yongseok; Cha, Sang-Mok; Poteet, Wade; Lam, Philip; Lee, Chung-Uk; Kim, Seung-Lee; Park, Byeong-Gon; Buchroeder, Richard A.; Jin, Ho

    2014-07-01

    We present the design, assembly, alignment, and verification process of the wide field corrector for the Korea Microlensing Telescope Network (KMTNet) 1.6 meter optical telescope. The optical configuration of the KMTNet telescope is prime focus, having a wide field corrector and the CCD camera on the topside of Optical Tube Assembly (OTA). The corrector is made of four lenses designed to have all spherical surfaces, being the largest one of 552 mm physical diameter. Combining with a purely parabolic primary mirror, this optical design makes easier to fabricate, to align, and to test the wide field optics. The centering process of the optics in the lens cell was performed on a precision rotary table using an indicator. After the centering, we mounted three large and heavy lenses on each cell by injecting the continuous Room Temperature Vulcanizing (RTV) silicon rubber bonding via a syringe.

  20. Achieving High Performance in AC-Field Driven Organic Light Sources

    PubMed Central

    Xu, Junwei; Carroll, David L.; Smith, Gregory M.; Dun, Chaochao; Cui, Yue

    2016-01-01

    Charge balance in organic light emitting structures is essential to simultaneously achieving high brightness and high efficiency. In DC-driven organic light emitting devices (OLEDs), this is relatively straight forward. However, in the newly emerging, capacitive, field-activated AC-driven organic devices, charge balance can be a challenge. In this work we introduce the concept of gating the compensation charge in AC-driven organic devices and demonstrate that this can result in exceptional increases in device performance. To do this we replace the insulator layer in a typical field-activated organic light emitting device with a nanostructured, wide band gap semiconductor layer. This layer acts as a gate between the emitter layer and the voltage contact. Time resolved device characterization shows that, at high-frequencies (over 40 kHz), the semiconductor layer allows for charge accumulation in the forward bias, light generating part of the AC cycle and charge compensation in the negative, quiescent part of the AC cycle. Such gated AC organic devices can achieve a non-output coupled luminance of 25,900 cd/m2 with power efficiencies that exceed both the insulator-based AC devices and OLEDs using the same emitters. This work clearly demonstrates that by realizing balanced management of charge, AC-driven organic light emitting devices may well be able to rival today’s OLEDs in performance. PMID:27063414

  1. Achieving High Performance in AC-Field Driven Organic Light Sources.

    PubMed

    Xu, Junwei; Carroll, David L; Smith, Gregory M; Dun, Chaochao; Cui, Yue

    2016-01-01

    Charge balance in organic light emitting structures is essential to simultaneously achieving high brightness and high efficiency. In DC-driven organic light emitting devices (OLEDs), this is relatively straight forward. However, in the newly emerging, capacitive, field-activated AC-driven organic devices, charge balance can be a challenge. In this work we introduce the concept of gating the compensation charge in AC-driven organic devices and demonstrate that this can result in exceptional increases in device performance. To do this we replace the insulator layer in a typical field-activated organic light emitting device with a nanostructured, wide band gap semiconductor layer. This layer acts as a gate between the emitter layer and the voltage contact. Time resolved device characterization shows that, at high-frequencies (over 40 kHz), the semiconductor layer allows for charge accumulation in the forward bias, light generating part of the AC cycle and charge compensation in the negative, quiescent part of the AC cycle. Such gated AC organic devices can achieve a non-output coupled luminance of 25,900 cd/m(2) with power efficiencies that exceed both the insulator-based AC devices and OLEDs using the same emitters. This work clearly demonstrates that by realizing balanced management of charge, AC-driven organic light emitting devices may well be able to rival today's OLEDs in performance. PMID:27063414

  2. Achieving High Performance in AC-Field Driven Organic Light Sources

    NASA Astrophysics Data System (ADS)

    Xu, Junwei; Carroll, David L.; Smith, Gregory M.; Dun, Chaochao; Cui, Yue

    2016-04-01

    Charge balance in organic light emitting structures is essential to simultaneously achieving high brightness and high efficiency. In DC-driven organic light emitting devices (OLEDs), this is relatively straight forward. However, in the newly emerging, capacitive, field-activated AC-driven organic devices, charge balance can be a challenge. In this work we introduce the concept of gating the compensation charge in AC-driven organic devices and demonstrate that this can result in exceptional increases in device performance. To do this we replace the insulator layer in a typical field-activated organic light emitting device with a nanostructured, wide band gap semiconductor layer. This layer acts as a gate between the emitter layer and the voltage contact. Time resolved device characterization shows that, at high-frequencies (over 40 kHz), the semiconductor layer allows for charge accumulation in the forward bias, light generating part of the AC cycle and charge compensation in the negative, quiescent part of the AC cycle. Such gated AC organic devices can achieve a non-output coupled luminance of 25,900 cd/m2 with power efficiencies that exceed both the insulator-based AC devices and OLEDs using the same emitters. This work clearly demonstrates that by realizing balanced management of charge, AC-driven organic light emitting devices may well be able to rival today’s OLEDs in performance.

  3. Wide field imaging problems in radio astronomy

    NASA Astrophysics Data System (ADS)

    Cornwell, T. J.; Golap, K.; Bhatnagar, S.

    2005-03-01

    The new generation of synthesis radio telescopes now being proposed, designed, and constructed face substantial problems in making images over wide fields of view. Such observations are required either to achieve the full sensitivity limit in crowded fields or for surveys. The Square Kilometre Array (SKA Consortium, Tech. Rep., 2004), now being developed by an international consortium of 15 countries, will require advances well beyond the current state of the art. We review the theory of synthesis radio telescopes for large fields of view. We describe a new algorithm, W projection, for correcting the non-coplanar baselines aberration. This algorithm has improved performance over those previously used (typically an order of magnitude in speed). Despite the advent of W projection, the computing hardware required for SKA wide field imaging is estimated to cost up to $500M (2015 dollars). This is about half the target cost of the SKA. Reconfigurable computing is one way in which the costs can be decreased dramatically.

  4. Aspects of thermal field by wide burnishing

    NASA Astrophysics Data System (ADS)

    Bobrovskij, N. M.; Melnikov, P. A.; Grigoriev, S. N.; Bobrovskij, I. N.

    2015-09-01

    This research features 3D model of development of thermal fields by wide burnishing. By development of 3D model the source of heat build-up is represented as additive aggregate of connecting by width of spot heat sources, operating on the surface of the tool.

  5. Aligned Immobilization of Proteins Using AC Electric Fields.

    PubMed

    Laux, Eva-Maria; Knigge, Xenia; Bier, Frank F; Wenger, Christian; Hölzel, Ralph

    2016-03-01

    Protein molecules are aligned and immobilized from solution by AC electric fields. In a single-step experiment, the enhanced green fluorescent proteins are immobilized on the surface as well as at the edges of planar nanoelectrodes. Alignment is found to follow the molecules' geometrical shape with their longitudinal axes parallel to the electric field. Simultaneous dielectrophoretic attraction and AC electroosmotic flow are identified as the dominant forces causing protein movement and alignment. Molecular orientation is determined by fluorescence microscopy based on polarized excitation of the proteins' chromophores. The chromophores' orientation with respect to the whole molecule supports X-ray crystal data. PMID:26779699

  6. Exchange anisotropy determined by magnetic field dependence of ac susceptibility

    NASA Astrophysics Data System (ADS)

    Rodríguez-Suárez, R. L.; Vilela Leão, L. H.; de Aguiar, F. M.; Rezende, S. M.; Azevedo, A.

    2003-10-01

    ac susceptibility measurements of ferromagnetic/antiferromagnetic (FM/AF) bilayers are usually performed as a function of the temperature. In this work we describe measurements of transverse biased ac susceptibility (χt) of FM/AF bilayers as a function of the applied magnetic field H0. The measurements were carried out at room temperature by means of an ac magneto-optical Kerr effect susceptometer. The χt-1(H0) dependence, at the saturation magnetization regime, exhibits a linear behavior with the applied field parallel and perpendicular to the exchange bias direction. The linear extrapolation of χt-1 versus H0 cuts the abscissa at asymmetrical values of field due to the exchange bias coupling. The inverse susceptibility is calculated in the saturation regime by a model, which takes into account the free energy of both layers plus a term corresponding to the interfacial coupling. The exchange coupling field (HE) and uniaxial anisotropy (HU) are extracted from the best fit to the experimental results. The results obtained are crosschecked by those obtained from ferromagnetic resonance (FMR) and dc magnetometry. The measurements of the exchange bias and the uniaxial field in all of the three analyzed bilayers gave values that are consistently lower when measured by FMR than those obtained by ac and dc magnetometry. It is argued that the apparently discrepant values of HE and HU, obtained by different techniques, might be explained by existence of unstable AF grains at the AF/FM interface.

  7. AC Electrostatic Field Study : Final Report.

    SciTech Connect

    Lebby, Gary L.

    1990-08-28

    The phenomenon of fast transients propagating to the outer sheath of a gas insulated substation (GIS) during switching and disconnect operations as well as the distortion of the electric field gradient around an electric transmission line in the presence of field measuring equipment are examples of electrostatic and electromagnetic field problems that are very much on the minds of both power engineers and maintenance personnel alike. Maintenance personnel working on high voltage equipment want to know the areas that have the highest electric field strength gradients and they want to reduce the risk of being shocked when touching a conventionally 60 Hz grounded GIS enclosure due to fast transients initiated by faults and switching operations. In studying these phenomena during the performance period of this grant, tower configurations for the electric field strength gradient measurements were tested with the ESURF3D program acquired from BPA and gas insulated substation test pole (GISTP) models were tested using the Alternative Transients Program (ATP) version Electromagnets Transients Program (EMTP). The results of these two modeling paradigms are presented in this report not as the last word on these subjects, but as a couple of the many ways one can approach two classical electromagnetic waves problems. 19 refs., 13 figs., 3 tabs.

  8. Astrometry in Wide-Field Surveys

    NASA Astrophysics Data System (ADS)

    Pál, A.; Bakos, G. Á.

    2007-07-01

    We present a general two-dimensional catalog matching algorithm that can efficiently be applied for wide-field astrometry where the acquired images are strained by distortions due to the large field-of-view. The algorithm is able to derive the transformations between a reference catalogue and the images up to arbitrary polynomial order. Our method is applied successfully in the Hungarian-made Automated Telescope Network \\citep[HATNet, see][]{bakos04} project both in real-time astrometrical guiding of the telescopes as well as during the reduction of the data. In this paper we summarize the key points of the newly developed parts of the algorithms as well as the performance on large set of wide FOV images taken by the telescopes of HATNet.

  9. Wide-field Infrared Survey Explorer

    NASA Technical Reports Server (NTRS)

    Padgett, Deborah

    2012-01-01

    We present WISE (Wide-field Infrared Survey Explorer) mid-infrared photometry of young stellar object candidates in the Canis Majoris clouds at a distance of 1 kpc. WISE has identified 682 objects with apparent 12 and 22 micron excess emission in a 7 deg x 10 deg field around the CMa Rl cloud . While a substantial fraction of these candidates are likely galaxies, AGB stars, and artifacts from confusion along the galactic plane, others are part of a spectacular cluster of YSOs imaged by WISE along a dark filament in the R1 cloud. Palomar Double Spectrograph observations of several sources in this cluster confirm their identity as young A and B stars with strong emission lines. In this contribution, we plot the optical -mid-infrared spectral energy distribution for the WISE YSO candidates and discuss potential contaminants to the sample . The data demonstrate the utility of WISE in performing wide-area surveys for young stellar objects.

  10. WIDE-FIELD ASTRONOMICAL MULTISCALE CAMERAS

    SciTech Connect

    Marks, Daniel L.; Brady, David J.

    2013-05-15

    In order to produce sufficiently low aberrations with a large aperture, telescopes have a limited field of view. Because of this narrow field, large areas of the sky at a given time are unobserved. We propose several telescopes based on monocentric reflective, catadioptric, and refractive objectives that may be scaled to wide fields of view and achieve 1.''1 resolution, which in most locations is the practical seeing limit of the atmosphere. The reflective and Schmidt catadioptric objectives have relatively simple configurations and enable large fields to be captured at the expense of the obscuration of the mirror by secondary optics, a defect that may be managed by image plane design. The refractive telescope design does not have an obscuration but the objective has substantial bulk. The refractive design is a 38 gigapixel camera which consists of a single monocentric objective and 4272 microcameras. Monocentric multiscale telescopes, with their wide fields of view, may observe phenomena that might otherwise be unnoticed, such as supernovae, glint from orbital space debris, and near-earth objects.

  11. Lensless imaging for wide field of view

    NASA Astrophysics Data System (ADS)

    Nagahara, Hajime; Yagi, Yasushi

    2015-02-01

    It is desirable to engineer a small camera with a wide field of view (FOV) because of current developments in the field of wearable cameras and computing products, such as action cameras and Google Glass. However, typical approaches for achieving wide FOV, such as attaching a fisheye lens and convex mirrors, require a trade-off between optics size and the FOV. We propose camera optics that achieve a wide FOV, and are at the same time small and lightweight. The proposed optics are a completely lensless and catoptric design. They contain four mirrors, two for wide viewing, and two for focusing the image on the camera sensor. The proposed optics are simple and can be simply miniaturized, since we use only mirrors for the proposed optics and the optics are not susceptible to chromatic aberration. We have implemented the prototype optics of our lensless concept. We have attached the optics to commercial charge-coupled device/complementary metal oxide semiconductor cameras and conducted experiments to evaluate the feasibility of our proposed optics.

  12. The Wide-Field Infrared Explorer

    NASA Technical Reports Server (NTRS)

    Schember, Helene; Hacking, Perry

    1993-01-01

    More than 30% of current star formation is taking place ingalaxies known as starburst galaxies. Do starburst galaxies play a central role in the evolution of all galaxies, and can they lead us to the birth of galaxies and the source of quasars? We have proposed to build the Wide Field Infrared Explorer (WIRE), capable of detecting typical starburst galaxies at a redshift of 0.5, ultraluminous infrared galaxies behond a redshift of 2, and luminous protogalaxies beyond a redshift of 5.

  13. Wide-field microscopy using microcamera arrays

    NASA Astrophysics Data System (ADS)

    Marks, Daniel L.; Youn, Seo Ho; Son, Hui S.; Kim, Jungsang; Brady, David J.

    2013-02-01

    A microcamera is a relay lens paired with image sensors. Microcameras are grouped into arrays to relay overlapping views of a single large surface to the sensors to form a continuous synthetic image. The imaged surface may be curved or irregular as each camera may independently be dynamically focused to a different depth. Microcamera arrays are akin to microprocessors in supercomputers in that both join individual processors by an optoelectronic routing fabric to increase capacity and performance. A microcamera may image ten or more megapixels and grouped into an array of several hundred, as has already been demonstrated by the DARPA AWARE Wide-Field program with multiscale gigapixel photography. We adapt gigapixel microcamera array architectures to wide-field microscopy of irregularly shaped surfaces to greatly increase area imaging over 1000 square millimeters at resolutions of 3 microns or better in a single snapshot. The system includes a novel relay design, a sensor electronics package, and a FPGA-based networking fabric. Biomedical applications of this include screening for skin lesions, wide-field and resolution-agile microsurgical imaging, and microscopic cytometry of millions of cells performed in situ.

  14. Absorption of ac fields in amorphous indium-oxide films

    SciTech Connect

    Ovadyahu, Z.

    2014-08-20

    Absorption data from applied ac fields in Anderson-localized amorphous indium-oxide (In{sub x}O) films are shown to be frequency and disorder dependent. The absorption shows a roll-off at a frequency which is much lower than the electron-electron scattering rate of the material when it is in the diffusive regime. This is interpreted as evidence for discreteness of the energy spectrum of the deeply localized regime. This is consistent with recent many-body localization scenarios. As the metal-insulator transition is approached, the absorption shifts to higher frequencies. Comparing with the previously obtained results on the crystalline version of indium-oxide (In{sub 2}O{sub 3−x}) implies a considerably higher inelastic electron-phonon scattering rate in the amorphous material. The range over which the absorption versus frequency decreases may indicate that a wide distribution of localization length is a common feature in these systems.

  15. The DESI Wide Field Corrector Optics

    SciTech Connect

    Doel, Peter; Sholl, Michael J.; Liang, Ming; Brooks, David; Flaugher, Brenna; Gutierrez, Gaston; Kent, Stephen; Lampton, Michael; Miller, Timothy; Sprayberry, David

    2014-01-01

    The Dark Energy Spectroscopic instrument (DESI) is a 5000 fiber multi-object spectrometer system under development for installation on the National Optical Astronomy Observatory (NOAO) Kitt Peak 4m telescope (the Mayall telescope). DESI is designed to perform a 14,000˚ (square) galaxy and Quasi-Stellar Object (QSO) redshift survey to improve estimates of the dark energy equation of state. The survey design imposes numerous constraints on a prime focus corrector design, including field of view, geometrical blur, stability, fiber injection efficiency, zenith angle, mass and cost. The DESI baseline wide-field optical design described herein provides a 3.2˚ diameter field of view with six 0.8- 1.14m diameter lenses and an integral atmospheric dispersion compensator.

  16. ``Superfast'' and ``Hyperfast'' Electrophoresis in DC and AC Electric Fields

    NASA Astrophysics Data System (ADS)

    Demekhin, Evgeny; Korovyakovsky, Alex

    2006-11-01

    Movement of a small conducting spherical granule in an electrolyte solution under force of DC and AC fields is considered. The problem is described by strongly coupled nonlinear PDE system. The fact that it has two small parameters, the ratio of the ion double layer to the diffusion layer and the ratio of the diffusion layer to the granule's diameter, makes the problem unique and extremely difficult to solve. This is the reason why only solutions for some particular cases have been known. In this work for the first time, combining asymptotic and numerical methods, a complete theory of electrophoresis in DC and AC fields is developed. By special decomposition method the system is transformed to new variables. Analytical solution in the inner region results in the nonlinear Smoluchowski slip velocity. In the intermediate region convection-diffusion equation is solved numerically. In tern, the intermediate solution is matched with the outer solution of Laplace equation to complete the statement. For a strong DC field (``superfast'' electrophoresis) the theory predicts, in agreement with experiments, the granule's velocity to be proportional to the granule's size and squared external field; there is a large elongated vortex behind the granule and a small one near its equator. There is an excellent agreement with available experimental data. Granule's velocity for AC field becomes even larger than for DC, it has a maximum with respect to the field's frequency (``hyperfast'' electrophoresis).

  17. Imaging spectrometer wide field catadioptric design

    DOEpatents

    Chrisp; Michael P.

    2008-08-19

    A wide field catadioptric imaging spectrometer with an immersive diffraction grating that compensates optical distortions. The catadioptric design has zero Petzval field curvature. The imaging spectrometer comprises an entrance slit for transmitting light, a system with a catadioptric lens and a dioptric lens for receiving the light and directing the light, an immersion grating, and a detector array. The entrance slit, the system for receiving the light, the immersion grating, and the detector array are positioned wherein the entrance slit transmits light to the system for receiving the light and the system for receiving the light directs the light to the immersion grating and the immersion grating receives the light and directs the light through the system for receiving the light to the detector array.

  18. Electrohydrodynamic instabilities in thin viscoelastic films: AC and DC fields

    NASA Astrophysics Data System (ADS)

    Espin, Leonardo; Corbett, Andrew; Kumar, Satish; Kumar Research Group Team

    2012-11-01

    Electrohydrodynamic instabilities in thin liquid films are a promising route for the self-assembly of well-defined topographical features on the surfaces of materials. Here, we study the effect of viscoelasticity on these instabilities under the influence of AC and DC electric fields. Viscoelasticity is incorporated via a Jeffreys model and both perfect and leaky dielectric materials are considered. In the case of DC fields, asymptotic methods are employed to shed light on the nature of a singularity that arises when solvent viscosity is neglected (i.e., the Maxwell-fluid limit). In the case of AC fields, we apply a numerical procedure based on Floquet theory to determine the maximum growth rate and corresponding wavenumber as a function of the oscillation amplitude and frequency. Elasticity is found to increase both the maximum growth rate and the corresponding wavenumber, with the effects being the most pronounced when the oscillation period is comparable to the fluid relaxation time.

  19. AC Electric Field Communication for Human-Area Networking

    NASA Astrophysics Data System (ADS)

    Kado, Yuichi; Shinagawa, Mitsuru

    We have proposed a human-area networking technology that uses the surface of the human body as a data transmission path and uses an AC electric field signal below the resonant frequency of the human body. This technology aims to achieve a “touch and connect” intuitive form of communication by using the electric field signal that propagates along the surface of the human body, while suppressing both the electric field radiating from the human body and mutual interference. To suppress the radiation field, the frequency of the AC signal that excites the transmitter electrode must be lowered, and the sensitivity of the receiver must be raised while reducing transmission power to its minimally required level. We describe how we are developing AC electric field communication technologies to promote the further evolution of a human-area network in support of ubiquitous services, focusing on three main characteristics, enabling-transceiver technique, application-scenario modeling, and communications quality evaluation. Special attention is paid to the relationship between electro-magnetic compatibility evaluation and regulations for extremely low-power radio stations based on Japan's Radio Law.

  20. Extending membrane pore lifetime with AC fields: A modeling study

    NASA Astrophysics Data System (ADS)

    Garner, Allen L.; Bogdan Neculaes, V.

    2012-07-01

    AC (sinusoidal) fields with frequencies from kilohertz to gigahertz have been used for gene delivery. To understand the impact of AC fields on electroporation dynamics, we couple a nondimensionalized Smoluchowski equation to an exact representation of the cell membrane voltage obtained solving the Laplace equation. The slope of the pore energy function, dφ/dr, with respect to pore radius is critical in predicting pore dynamics in AC fields because it can vary from positive, inducing pore shrinkage, to negative, driving pore growth. Specifically, the net sign of the integral of dφ/dr over time determines whether the average pore size grows (negative), shrinks (positive), or oscillates (zero) indefinitely about a steady-state radius, rss. A simple analytic relationship predicting the amplitude of the membrane voltage necessary for this behavior agrees well with simulation for frequencies from 500 kHz to 5 MHz for rss < 10 nm. For larger pore size (rss > 10 nm), dφ/dr oscillates about a negative value, suggesting that a net creation of pores may be necessary to maintain a constant pore size. In both scenarios, the magnitude of rss depends only upon the amplitude of the membrane voltage and not directly upon the applied field frequency other than the relationship between the amplitudes of the applied field and membrane voltage.

  1. Hubble Space Telescope, Wide Field Planetary Camera

    NASA Technical Reports Server (NTRS)

    1981-01-01

    This illustration is a diagram of the Hubble Space Telescope's (HST's), Wide Field Planetary Camera (WF/PC), one of the five Scientific Instruments. The WF/PC uses a four-sided pyramid mirror to split a light image into quarters. It then focuses each quadrant onto one of two sets of four sensors. The sensors are charge-coupled detectors and function as the electronic equivalent of extremely sensitive photographic plates. The WF/PC operates in two modes. The Wide-Field mode that will view 7.2-arcmin sections of the sky, and the Planetary mode that will look at narrower fields of view, such as planets or areas within other galaxies. The purpose of the HST, the most complex and sensitive optical telescope ever made, is to study the cosmos from a low-Earth orbit. By placing the telescope in space, astronomers are able to collect data that is free of the Earth's atmosphere. The HST detects objects 25 times fainter than the dimmest objects seen from Earth and provides astronomers with an observable universe 250 times larger than visible from ground-based telescopes, perhaps as far away as 14 billion light-years. The HST views galaxies, stars, planets, comets, possibly other solar systems, and even unusual phenomena such as quasars, with 10 times the clarity of ground-based telescopes. The HST was deployed from the Space Shuttle Discovery (STS-31 mission) into Earth orbit in April 1990. The Marshall Space Flight Center had responsibility for design, development, and construction of the HST. The Perkin-Elmer Corporation, in Danbury, Cornecticut, developed the optical system and guidance sensors.

  2. Wide field-of-view bifocal eyeglasses

    NASA Astrophysics Data System (ADS)

    Barbero, Sergio; Rubinstein, Jacob

    2015-09-01

    When vision is affected simultaneously by presbyopia and myopia or hyperopia, a solution based on eyeglasses implies a surface with either segmented focal regions (e.g. bifocal lenses) or a progressive addition profile (PALs). However, both options have the drawback of reducing the field-of-view for each power position, which restricts the natural eye-head movements of the wearer. To avoid this serious limitation we propose a new solution which is essentially a bifocal power-adjustable optical design ensuring a wide field-of-view for every viewing distance. The optical system is based on the Alvarez principle. Spherical refraction correction is considered for different eccentric gaze directions covering a field-of-view range up to 45degrees. Eye movements during convergence for near objects are included. We designed three bifocal systems. The first one provides 3 D for far vision (myopic eye) and -1 D for near vision (+2 D Addition). The second one provides a +3 D addition with 3 D for far vision. Finally the last system is an example of reading glasses with +1 D power Addition.

  3. Wide field camera observations of Baade's Window

    NASA Technical Reports Server (NTRS)

    Holtzman, Jon A.; Light, R. M.; Baum, William A.; Worthey, Guy; Faber, S. M.; Hunter, Deidre A.; O'Neil, Earl J., Jr.; Kreidl, Tobias J.; Groth, E. J.; Westphal, James A.

    1993-01-01

    We have observed a field in Baade's Window using the Wide Field Camera (WFC) of the Hubble Space Telescope (HST) and obtain V- and I-band photometry down to V approximately 22.5. These data go several magnitudes fainter than previously obtained from the ground. The location of the break in the luminosity function suggests that there are a significant number of intermediate age (less than 10 Gyr) stars in the Galactic bulge. This conclusion rests on the assumptions that the extinction towards our field is similar to that seen in other parts of Baade's Window, that the distance to the bulge is approximately 8 kpc, and that we can determine fairly accurate zero points for the HST photometry. Changes in any one of these assumptions could increase the inferred age, but a conspiracy of lower reddening, a shorter distance to the bulge, and/or photometric zero-point errors would be needed to imply a population entirely older than 10 Gyr. We infer an initial mass function slope for the main-sequence stars, and find that it is consistent with that measured in the solar neighborhood; unfortunately, the slope is poorly constrained because we sample only a narrow range of stellar mass and because of uncertainties in the observed luminosity function at the faint end.

  4. AC Magnetic Field Frequency Dependence of Magnetoacoustic Emission

    NASA Technical Reports Server (NTRS)

    Namkung, M.; Wincheski, B.; Fulton, J. P.; DeNale, R.

    1992-01-01

    Our recent study has proved a strong correlation between the low-frequency AC applied magnetic field amplitude dependence of the asymmetry of the magnetoacoustic emission (MAE) burst and the strength of the domain wall-defect interaction in iron-base ferromagnets. For the present study the AC magnetic field frequency dependence of the asymmetry has been investigated in the range of 1 to 200 Hz. When represented by the third moment of the rectified acoustic emission pulses, the asymmetry becomes a bell-shaped function of frequency with its center located around 25 Hz. This experiment has been performed with low carbon, high yield stress steel specimens of three different levels of domain wall-defect interaction strength. The results show that the increase in the interaction strength causes a vertical down shift of the asymmetry in the entire frequency range investigated.

  5. Okayama astrophysical observatory wide field camera

    NASA Astrophysics Data System (ADS)

    Yanagisawa, Kenshi; Shimizu, Yasuhiro; Okita, Kiichi; Kuroda, Daisuke; Koyano, Hisashi; Tsutsui, Hironori; Toda, Hiroyuki; Izumiura, Hideyuki; Yoshida, Michitoshi; Ohta, Kouji; Kawai, Nobuyuki; Yamamuro, Tomoyasu

    2014-08-01

    Okayama Astrophysical Observatory Wide Field Camera: OAOWFC is a near-infrared (0.9-2.5 μm) survey telescope, whose aperture is 0.91m. It works at Y, J, H, and Ks bands. The optics are consisted of forward Cassegrain and quasi Schmidt which yield the image circle of Φ 52 mm or Φ 1.3 deg at the focal plane. The overall F-ratio is F/2.51 which is one of the fastest among near infrared imagers in the world. A HAWAII-1 detector array placed at the focal plane cuts the central 0.48 deg. x 0.48 deg. with a pixel scale of 1.67 arcsec/pix. It will be used to survey the Galactic plane for variability and search for transients such as Gamma-ray burst afterglows optical counterpart of gravitational wave sources.

  6. A Wide Field of View Plasma Spectrometer

    DOE PAGESBeta

    Skoug, Ruth M.; Funsten, Herbert O.; Moebius, Eberhard; Harper, Ron W.; Kihara, Keith H.; Bower, Jonathan S.

    2016-07-23

    Here we present a fundamentally new type of space plasma spectrometer, the wide field of view plasma spectrometer, whose field of view is >1.25π ster using fewer resources than traditional methods. The enabling component is analogous to a pinhole camera with an electrostatic energy-angle filter at the image plane. Particle energy-per-charge is selected with a tunable bias voltage applied to the filter plate relative to the pinhole aperture plate. For a given bias voltage, charged particles from different directions are focused by different angles to different locations. Particles with appropriate locations and angles can transit the filter plate and aremore » measured using a microchannel plate detector with a position-sensitive anode. Full energy and angle coverage are obtained using a single high-voltage power supply, resulting in considerable resource savings and allowing measurements at fast timescales. Lastly, we present laboratory prototype measurements and simulations demonstrating the instrument concept and discuss optimizations of the instrument design for application to space measurements.« less

  7. Lipid Bilayer Vesicle Dynamics in AC Electric Fields

    NASA Astrophysics Data System (ADS)

    McConnell, Lane; Vlahovska, Petia; Miksis, Michael

    2014-11-01

    Vesicles are closed, fluid-filled lipid bilayers which are mechanically similar to biological cells and which undergo shape transitions in the presence of electric fields. Here we model the vesicle membrane as an infinitely thin, capacitive, area-incompressible interface with the surrounding fluids acting as charge-advecting leaky dielectrics. We then implement the boundary integral method to numerically investigate the dynamics of a vesicle in various AC electric field profiles. Our numerical results are then compared with recent small deformation theory and experimental data. We also note our observation of a new theoretical vesicle behavior that has yet to be observed experimentally.

  8. A new AC susceptibility instrument for detecting frequency dependence over a wide range of frequencies

    NASA Astrophysics Data System (ADS)

    Kodama, K.

    2008-12-01

    A unique equipment was developed for measuring low-field AC susceptibility over a frequency spectrum ranging from 10 Hz to 4 kHz. The coil system consists of a primary coil for applying an excitation field, and a set of pickup coils linked in series and wound oppositely for compensation. The number of turns for the primary coil is 6,000 and that for the pickup coils is 4,400, using 0.1 mm thick copper wire, wound around a quartz-glass tube of 36 mm in diameter, allowing to measure conventional 10cc samples. The excitation field is produced by a commercial function generator with two independent outputs, capable of generating sinusoidal current with frequencies of 0 to 10 MHz. A mutual inductor coil is connected in series, to which the wave generator supplies, through the second output, a small current that can be adjusted in phase and magnitude to compensate the out-of-balance of the pickup coils. The resulting signal output voltage is fed to a digital rock-in amplifier. The AC frequency spans practically from 10 Hz to 4 kHz due to the limitation of the lock-in amplifier, but can be swept over the entire range with a constant amplitude of the applied field, which is changeable from 0.4 to 1.0 Oe. The outputs from the lock-in amplifier, in both magnitude and phase, are transferred to a PC to obtain the frequency dependence spectrum of both real and imaginary parts of AC susceptibility. The system calibration was made using a paramagnetic Gd2O3 powder as well as several natural samples that have ever been used for inter-laboratory calibrations.

  9. Adaptive wide-field optical tomography

    NASA Astrophysics Data System (ADS)

    Venugopal, Vivek; Intes, Xavier

    2013-03-01

    We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increases the number of measurements collected with high photon counts resulting in a dataset with improved tomographic information. Herein, this imaging technique is applied to time-resolved fluorescence molecular tomography for preclinical studies. First, the merit of this approach is tested by in silico studies in a synthetic small animal model for typical illumination patterns. Second, the applicability of this approach in tomographic imaging is validated in vitro using a small animal phantom with two fluorescent capillaries occluded by a highly absorbing inclusion. The simulation study demonstrates an improvement of signal transmitted (˜2 orders of magnitude) through the central portion of the small animal model for all patterns considered. A corresponding improvement in the signal at the emission wavelength by 1.6 orders of magnitude demonstrates the applicability of this technique for fluorescence molecular tomography. The successful discrimination and localization (˜1 mm error) of the two objects with higher resolution using the optimized patterns compared with nonoptimized illumination establishes the improvement in reconstruction performance when using this technique.

  10. Wide-angle flat field telescope

    NASA Technical Reports Server (NTRS)

    Hallam, K. L.; Howell, B. J.; Wilson, M. E.

    1986-01-01

    Described is an unobscured three mirror wide angle telescopic imaging system comprised of an input baffle which provides a 20 deg (Y axis) x 30 deg (X axis) field of view, a primary mirror having a convex spherical surface, a secondary mirror having a concave ellipsoidal reflecting surface, a tertiary mirror having a concave spherical reflecting surface. The mirrors comprise mirror elements which are offset segments of parent mirrors whose axes and vertices commonly lie on the system's optical axis. An iris diaphragm forming an aperture stop is located between the secondary and tertiary mirror with its center also being coincident with the optical axis and being further located at the beam waist of input light beams reflected from the primary and secondary mirror surfaces. At the system focus following the tertiary mirror is located a flat detector which may be, for example, a TV imaging tube or a photographic film. When desirable, a spectral transmission filter is placed in front of the detector in close proximity thereto.

  11. Collapse of DNA in a.c. electric fields

    PubMed Central

    Zhou, Chunda; Reisner, Walter W.; Staunton, Rory J.; Ashan, Amir; Austin, Robert H.; Riehn, Robert

    2013-01-01

    We report that double-stranded DNA collapses in presence of a.c. electric fields at frequencies of a few hundred Hertz, and does not stretch as commonly assumed. In particular, we show that confinement-stretched DNA can collapse to about one quarter of its equilibrium length. We propose that this effect is based on finite relaxation times of the counterion cloud, and the subsequent partitioning of the molecule into mutually attractive units. We discuss alternative models of those attractive units. PMID:21770604

  12. The wide field imager instrument for Athena

    NASA Astrophysics Data System (ADS)

    Meidinger, Norbert; Nandra, Kirpal; Plattner, Markus; Porro, Matteo; Rau, Arne; Santangelo, Andrea E.; Tenzer, Chris; Wilms, Jörn

    2014-07-01

    The "Hot and Energetic Universe" has been selected as the science theme for ESA's L2 mission, scheduled for launch in 2028. The proposed Athena X-ray observatory provides the necessary capabilities to achieve the ambitious goals of the science theme. The X-ray mirrors are based on silicon pore optics technology and will have a 12 m focal length. Two complementary camera systems are foreseen which can be moved in and out of the focal plane by an interchange mechanism. These instruments are the actively shielded micro-calorimeter spectrometer X-IFU and the Wide Field Imager (WFI). The WFI will combine an unprecedented survey power through its large field of view of 40 arcmin with a high countrate capability (approx. 1 Crab). It permits a state-of-the-art energy resolution in the energy band of 0.1 keV to 15 keV during the entire mission lifetime (e.g. FWHM <= 150 eV at 6 keV). This performance is accomplished by a set of DEPFET active pixel sensor matrices with a pixel size matching the angular resolution of 5 arcsec (on-axis) of the mirror system. Each DEPFET pixel is a combined detector-amplifier structure with a MOSFET integrated onto a fully depleted 450 micron thick silicon bulk. The signal electrons generated by an X-ray photon are collected in a so-called internal gate below the transistor channel. The resulting change of the conductivity of the transistor channel is proportional to the number of electrons and thus a measure for the photon energy. DEPFETs have already been developed for the "Mercury Imaging X-ray Spectrometer" on-board of ESA's BepiColombo mission. For Athena we develop enhanced sensors with integrated electronic shutter and an additional analog storage area in each pixel. These features improve the peak-to-background ratio of the spectra and minimize dead time. The sensor will be read out with a new, fast, low-noise multi-channel analog signal processor with integrated sequencer and serial analog output. The architecture of sensor and readout

  13. Field-dependence of AC susceptibility in titanomagnetites

    USGS Publications Warehouse

    Jackson, M.; Moskowitz, B.; Rosenbaum, J.; Kissel, Catherie

    1998-01-01

    AC susceptibility measurements as a function of field amplitude Hac and of frequency show a strong field dependence for a set of synthetic titanomagnetites (Fe3-xTixO4) and for certain basalts from the SOH-1 Hawaiian drill hole and from Iceland. In-phase susceptibility is constant below fields of about 10-100 A/m, and then increases by as much as a factor of two as Hsc is increased to 2000 A/m. Both the initial field-independent susceptibilities and field-dependence of susceptibility are systematically related to composition: initial susceptibility is 3 SI for a single-crystal sphere of TMO (x = 0) and decreases with increasing titanium content; field-dependence is nearly zero for TM0 and increases systematically to a maximum near TM60 (x = 0.6). This field dependence can in some cases be mistaken for frequency dependence, and leaf to incorrect interpretations of magnetic grain size and composition when titanomagnetite is present.

  14. Resonant tunneling of interacting electrons in an AC electric field

    SciTech Connect

    Elesin, V. F.

    2013-11-15

    The problem of the effect of electron-electron interaction on the static and dynamic properties of a double-barrier nanostructure (resonant tunneling diode (RTD)) is studied in terms of a coherent tunneling model, which includes a set of Schrödinger and Poisson equations with open boundary conditions. Explicit analytical expressions are derived for dc and ac potentials and reduced (active and reactive) currents in the quasi-classical approximation over a wide frequency range. These expressions are used to analyze the frequency characteristics of RTD. It is shown that the interaction can radically change the form of these expressions, especially in the case of a hysteretic I-V characteristic. In this case, the active current and the ac potentials can increase sharply at both low and high frequencies. For this increase to occur, it is necessary to meet quantum regime conditions and to choose a proper working point in the I-V characteristic of RTD. The possibility of appearance of specific plasma oscillations, which can improve the high-frequency characteristics of RTD, is predicted. It is found that the active current can be comparable with the resonant dc current of RTD.

  15. AC magnetic field losses in BSCCO-2223 superconducting tapes

    SciTech Connect

    Lelovic, M.; Mench, S.; Deis, T.

    1997-09-01

    The AC magnetic losses at power frequencies (60 Hz) were investigated for mono- and multifilament Ag-sheathed (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (BSCCO-2223) tapes with similar transport critical current (I{sub c}) values at 77 K. The multifilament sample exhibited higher losses than the monofilament under the same conditions. Loss peaks are discussed in terms of intergranular, intragranular and eddy current losses. Because of BSCCO`s anisotropy, field orientation has a large effect on the magnitude of these peaks, even at relatively small angles. Losses for fields applied parallel to the c-axis of the textured BSCCO grains are larger by more than one order of magnitude than those applied perpendicular.

  16. Wide-Angle, Flat-Field Telescope

    NASA Technical Reports Server (NTRS)

    Hallam, K. L.; Howell, B. J.; Wilson, M. E.

    1987-01-01

    All-reflective system unvignetted. Wide-angle telescope uses unobstructed reflecting elements to produce flat image. No refracting elements, no chromatic aberration, and telescope operates over spectral range from infrared to far ultraviolet. Telescope used with such image detectors as photographic firm, vidicons, and solid-state image arrays.

  17. ac-Field-induced fluid pumping in microsystems with asymmetric temperature gradients.

    PubMed

    Holtappels, Moritz; Stubbe, Marco; Gimsa, Jan

    2009-02-01

    We present two different designs of electrohydrodynamic micropumps for microfluidic systems. The micropumps have no movable parts, and their simple design allows for fabrication by microsystems technology. The pumps are operated by ac voltages from 1 to 60 V and were tested with aqueous solutions in the conductivity range of 1-112 mS m(-1). The pump effect is induced by an ac electric field across a fluid medium with an inhomogeneous temperature distribution. It is constant over a wide range of the ac field frequency with a conductivity-dependent drop-off at high frequencies. The temperature-dependent conductivity and permittivity distributions in the fluid induce space charges that interact with the electric field and induce fluid motion. The temperature distribution can be generated either by Joule heating in the medium or by external heating. We present experimental results obtained with two prototypes featuring Joule heating and external heating by a heating filament. Experimental and numerical results are compared with an analytical model. PMID:19391842

  18. Wide Area Wind Field Monitoring Status & Results

    SciTech Connect

    Alan Marchant; Jed Simmons

    2011-09-30

    Volume-scanning elastic has been investigated as a means to derive 3D dynamic wind fields for characterization and monitoring of wind energy sites. An eye-safe volume-scanning lidar system was adapted for volume imaging of aerosol concentrations out to a range of 300m. Reformatting of the lidar data as dynamic volume images was successfully demonstrated. A practical method for deriving 3D wind fields from dynamic volume imagery was identified and demonstrated. However, the natural phenomenology was found to provide insufficient aerosol features for reliable wind sensing. The results of this study may be applicable to wind field measurement using injected aerosol tracers.

  19. Hierarchical assembly of anisotropic particles in AC electric fields

    NASA Astrophysics Data System (ADS)

    Torres Diaz, Isaac; Rupp, Bradley; Hua, Xiaoqing; Yang, Yuguang; Bevan, Michael A.

    Hierarchical microstructures composed of colloids are of great interest for technological applications and advanced materials such as metamaterials and microfluidic devices. The dynamics of spherical colloidal particles has been analyzed previously for several systems, and has led to the control of the formation of perfect crystals using AC electric fields. However, spherical particles do not have a dependence on its orientation as anisotropic particles. Recently, researchers reported experiments showing the capabilities of anisotropic particles to assemble in different configurations, yet a detailed understanding of the mechanism and control is lacking. This work shows both theoretical and experimental results of the control of a colloidal system composed of anisotropic colloidal particles with a tri-axial ellipsoidal shape subjected to a non-uniform electric field close to a planar wall. We show that particles pack into different structures and orientations as a function of the applied electric field amplitude and frequency by taking into account dipole-field, dipole-dipole, and colloidal interactions. This analysis provides a theoretical framework for the equilibrium and non-equilibrium structures that can be formed via field mediated interaction, which are validated by experimental microscopy results, and can ultimately be used to engineer the hierarchical assembly of anisotropic particles.

  20. Wide field strip-imaging optical system

    NASA Technical Reports Server (NTRS)

    Vaughan, Arthur H. (Inventor)

    1994-01-01

    A strip imaging wide angle optical system is provided. The optical system is provided with a 'virtual' material stop to avoid aberrational effects inherent in wide angle optical systems. The optical system includes a spherical mirror section for receiving light from a 180-degree strip or arc of a target image. Light received by the spherical mirror section is reflected to a frusto-conical mirror section for subsequent rereflection to a row of optical fibers. Each optical fiber transmits a portion of the received light to a detector. The optical system exploits the narrow cone of acceptance associated with optical fibers to substantially eliminate vignetting effects inherent in wide-angle systems. Further, the optical system exploits the narrow cone of acceptance of the optical fibers to substantially limit spherical aberration. The optical system is ideally suited for any application wherein a 180-degree strip image need be detected, and is particularly well adapted for use in hostile environments such as in planetary exploration.

  1. Electrohydrodynamics of suspension of liquid drops in AC fields

    NASA Astrophysics Data System (ADS)

    Abdul Halim, Md.; Esmaeeli, Asghar

    2012-11-01

    Manipulation of liquid drops by an externally applied electric field is currently the focus of increased attention because of its relevance in a broad range of industrial processes. The effect of a uniform DC electric field on a solitary drop is well studied; however, less is know about the impact of electric field on suspension of liquid drops, and very little information is available on the impact of AC field on a single or a suspension of drops. Here we report the results of Direct Numerical Simulations of electrohydrodynamics of suspension of liquid drops. The governing equations are solved using a front tracking/finite difference technique, in conjunction with Taylor's leaky dielectric model. The imposed electric potential comprises of two parts, a time-independent base and a time-dependent part. The goal is to explore the relative importance of these two components in setting the statistically steady state behavior of the suspension. To this end, we report the results of three sets of simulations, where (i) the time-dependent part act as a perturbation on the base potential, (ii) the two components are of the same order, and (iii) the time-dependent part is much larger than the base potential. The problem is studied as a function of the governing nondimensional parameters.

  2. Constructive and destructive interferences of Stark resonances induced by an ac field in atomic hydrogen

    SciTech Connect

    Pawlak, Mariusz; Bylicki, Miroslaw; Moiseyev, Nimrod; Sindelka, Milan

    2010-12-15

    We study theoretically the problem of a hydrogen atom exposed both to a static dc field and to a monochromatic ac field. We show that, in the presence of an ac field, a constructive (or destructive) interference occurs between the excited (Rydberg) Stark resonance states and the hydrogenic ground state. This mechanism is responsible for dramatic enhancement (or suppression) of the corresponding photoionization rates.

  3. AC Electric Field Activated Shape Memory Polymer Composite

    NASA Technical Reports Server (NTRS)

    Kang, Jin Ho; Siochi, Emilie J.; Penner, Ronald K.; Turner, Travis L.

    2011-01-01

    Shape memory materials have drawn interest for applications like intelligent medical devices, deployable space structures and morphing structures. Compared to other shape memory materials like shape memory alloys (SMAs) or shape memory ceramics (SMCs), shape memory polymers (SMPs) have high elastic deformation that is amenable to tailored of mechanical properties, have lower density, and are easily processed. However, SMPs have low recovery stress and long response times. A new shape memory thermosetting polymer nanocomposite (LaRC-SMPC) was synthesized with conductive fillers to enhance its thermo-mechanical characteristics. A new composition of shape memory thermosetting polymer nanocomposite (LaRC-SMPC) was synthesized with conductive functionalized graphene sheets (FGS) to enhance its thermo-mechanical characteristics. The elastic modulus of LaRC-SMPC is approximately 2.7 GPa at room temperature and 4.3 MPa above its glass transition temperature. Conductive FGSs-doped LaRC-SMPC exhibited higher conductivity compared to pristine LaRC SMP. Applying an electric field at between 0.1 Hz and 1 kHz induced faster heating to activate the LaRC-SMPC s shape memory effect relative to applying DC electric field or AC electric field at frequencies exceeding1 kHz.

  4. Universal features of particle motion in ac electric fields

    NASA Astrophysics Data System (ADS)

    Niemeyer, L.; Seeger, M.

    2015-11-01

    Mobile particles present as contaminants in high voltage gas insulated switchgear (GIS) may constitute a risk for insulation failure. The understanding of their motion in the electric field of the insulation gap is therefore essential for quality control in manufacturing, commissioning and in service monitoring. Published research on particle motion in ac electric fields has shown that this rather complex process depends on numerous parameters, many of which remain unknown under practical conditions. This renders modelling, generalization of experimental data and practical application difficult. The scope of this paper therefore is to develop a unified description of particle motion which minimizes the number of controlling parameters, enables the comparison of experimental data and allows simple interpretation relations to be derived. This is achieved by making the controlling equations dimensionless with an appropriate choice of reference values and by using simplifying assumptions for the specific conditions prevailing in GIS. The resulting generalized description of the process can then be summarized in the form of 2D patterns (dynamic maps). Approximate scaling relations are derived between specific features of these patterns and particle-related parameters. A reference case is discussed in detail. The non-linear character of the equation of motion suggests that the particle motion may be a deterministic process with chaotic features. This is confirmed by a preliminary chaos-theoretical analysis of the process.

  5. Rapid magnetic microfluidic mixer utilizing AC electromagnetic field.

    PubMed

    Wen, Chih-Yung; Yeh, Cheng-Peng; Tsai, Chien-Hsiung; Fu, Lung-Ming

    2009-12-01

    This paper presents a novel simple micromixer based on stable water suspensions of magnetic nanoparticles (i.e. ferrofluids). The micromixer chip is built using standard microfabrication and simple soft lithography, and the design can be incorporated as a subsystem into any chemical microreactor or a miniaturized biological sensor. An electromagnet driven by an AC power source is used to induce transient interactive flows between a ferrofluid and Rhodamine B. The alternative magnetic field causes the ferrofluid to expand significantly and uniformly toward Rhodamine B, associated with a great number of extremely fine fingering structures on the interface in the upstream and downstream regions of the microchannel. These pronounced fingering patterns, which have not been observed by other active mixing methods utilizing only magnetic force, increase the mixing interfacial length dramatically. Along with the dominant diffusion effects occurring around the circumferential regions of the fine finger structures, the mixing efficiency increases significantly. The miscible fingering instabilities are observed and applied in the microfluidics for the first time. This work is carried with a view to developing functionalized ferrofluids that can be used as sensitive pathogen detectors and the present experimental results demonstrate that the proposed micromixer has excellent mixing capabilities. The mixing efficiency can be as high as 95% within 2.0 s and a distance of 3.0 mm from the inlet of the mixing channel, when the applied peak magnetic field is higher than 29.2 Oe and frequency ranges from 45 to 300 Hz. PMID:19921677

  6. Concentrating membrane proteins using asymmetric traps and AC electric fields.

    PubMed

    Cheetham, Matthew R; Bramble, Jonathan P; McMillan, Duncan G G; Krzeminski, Lukasz; Han, Xiaojun; Johnson, Benjamin R G; Bushby, Richard J; Olmsted, Peter D; Jeuken, Lars J C; Marritt, Sophie J; Butt, Julea N; Evans, Stephen D

    2011-05-01

    Membrane proteins are key components of the plasma membrane and are responsible for control of chemical ionic gradients, metabolite and nutrient transfer, and signal transduction between the interior of cells and the external environment. Of the genes in the human genome, 30% code for membrane proteins (Krogh et al. J. Mol. Biol.2001, 305, 567). Furthermore, many FDA-approved drugs target such proteins (Overington et al. Nat. Rev. Drug Discovery 2006, 5, 993). However, the structure-function relationships of these are notably sparse because of difficulties in their purification and handling outside of their membranous environment. Methods that permit the manipulation of membrane components while they are still in the membrane would find widespread application in separation, purification, and eventual structure-function determination of these species (Poo et al. Nature 1977, 265, 602). Here we show that asymmetrically patterned supported lipid bilayers in combination with AC electric fields can lead to efficient manipulation of charged components. We demonstrate the concentration and trapping of such components through the use of a "nested trap" and show that this method is capable of yielding an approximately 30-fold increase in the average protein concentration. Upon removal of the field, the material remains trapped for several hours as a result of topographically restricted diffusion. Our results indicate that this method can be used for concentrating and trapping charged membrane components while they are still within their membranous environment. We anticipate that our approach could find widespread application in the manipulation and study of membrane proteins. PMID:21476549

  7. Optical design of interferometric telescopes with wide fields of view.

    PubMed

    Sabatke, Erin E; Burge, James H; Hinz, Philip

    2006-11-01

    The performance of wide-field multiple-aperture imaging systems is dominated by easily understood, low-order errors. Each aperture produces an individual image, each pair of apertures produces a set of fringes under a diffraction envelope, and the system bandwidth produces a coherence envelope. For wide-field imaging, each of these elements must be coincident in the image plane as the field angle changes. We explore the causes of image degradation, derive first-order rules for preserving image quality across field, and give an example design that enforces some of the rules to achieve a relatively wide-field interferometric imaging telescope. PMID:17068543

  8. Particle Agglomeration in Bipolar Barb Agglomerator Under AC Electric Field

    NASA Astrophysics Data System (ADS)

    Huang, Chao; Ma, Xiuqin; Sun, Youshan; Wang, Meiyan; Zhang, Changping; Lou, Yueya

    2015-04-01

    The development of an efficient technology for removing fine particles in flue gas is essential as the haze is becoming more and more serious. To improve agglomeration effectiveness of fine particles, a dual zone electric agglomeration device consisting of a charging chamber and an agglomeration chamber with bipolar barb electrodes was developed. The bipolar barb electric agglomerator with a polar distance of 200 mm demonstrates good agglomeration effectiveness for particles with a size less than 8.0 μm under applied AC electric field. An optimal condition for achieving better agglomeration effectiveness was found to be as follows: flue gas flow velocity of 3.00 m/s, particle concentration of 2.00 g/m3, output voltage of 35 kV and length of the barb of 16 mm. In addition, 4.0-6.0 μm particles have the best effectiveness with the variation of particle volume occupancy of -3.2. supported by the Key Technology R&D Program of Hebei, China (No. 13211207D)

  9. Absorption and Attenuation Coefficients Using the WET Labs ac-s in the Mid-Atlantic Bight: Field Measurements and Data Analysis

    NASA Technical Reports Server (NTRS)

    Ohi, Nobuaki; Makinen, Carla P.; Mitchell, Richard; Moisan, Tiffany A.

    2008-01-01

    Ocean color algorithms are based on the parameterization of apparent optical properties as a function of inherent optical properties. WET Labs underwater absorption and attenuation meters (ac-9 and ac-s) measure both the spectral beam attenuation [c (lambda)] and absorption coefficient [a (lambda)]. The ac-s reports in a continuous range of 390-750 nm with a band pass of 4 nm, totaling approximately 83 distinct wavelengths, while the ac-9 reports at 9 wavelengths. We performed the ac-s field measurements at nine stations in the Mid-Atlantic Bight from water calibrations to data analysis. Onboard the ship, the ac-s was calibrated daily using Milli Q-water. Corrections for the in situ temperature and salinity effects on optical properties of water were applied. Corrections for incomplete recovery of the scattered light in the ac-s absorption tube were performed. The fine scale of spectral and vertical distributions of c (lambda) and a (lambda) were described from the ac-s. The significant relationships between a (674) and that of spectrophotometric analysis and chlorophyll a concentration of discrete water samples were observed.

  10. Resonant transport through a carbon nanotube junction exposed to an ac field.

    PubMed

    Shafranjuk, S E

    2011-12-14

    The electron transport through a carbon nanotube (CNT) double barrier junction exposed to an external electromagnetic field is studied. The electron spectrum in the quantum well (QW) formed by the junction bears relativistic features. We examine how the ac field affects the level quantization versus the ac field parameters and chirality. We find that the transport through the junction changes dramatically versus the ac field frequency and amplitude. These changes are pronounced in the junction's differential conductance, which allows judgment about the role of relativistic effects in the CNT QW structures. PMID:22109843

  11. The Wide-Field Imaging Interferometry Testbed: Recent Progress

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.

    2010-01-01

    The Wide-Field Imaging Interferometry Testbed (WIIT) at NASA's Goddard Space Flight Center was designed to demonstrate the practicality and application of techniques for wide-field spatial-spectral ("double Fourier") interferometry. WIIT is an automated system, and it is now producing substantial amounts of high-quality data from its state-of-the-art operating environment, Goddard's Advanced Interferometry and Metrology Lab. In this paper, we discuss the characterization and operation of the testbed and present the most recent results. We also outline future research directions. A companion paper within this conference discusses the development of new wide-field double Fourier data analysis algorithms.

  12. Patterns driven by combined ac and dc electric fields in nematic liquid crystals.

    PubMed

    Krekhov, Alexei; Decker, Werner; Pesch, Werner; Eber, Nándor; Salamon, Péter; Fekete, Balázs; Buka, Agnes

    2014-05-01

    The effect of superimposed ac and dc electric fields on the formation of electroconvection and flexoelectric patterns in nematic liquid crystals was studied. For selected ac frequencies, an extended standard model of the electrohydrodynamic instabilities was used to characterize the onset of pattern formation in the two-dimensional parameter space of the magnitudes of the ac and dc electric field components. Numerical as well as approximate analytical calculations demonstrate that depending on the type of patterns and on the ac frequency, the combined action of ac and dc fields may either enhance or suppress the formation of patterns. The theoretical predictions are qualitatively confirmed by experiments in most cases. Some discrepancies, however, seem to indicate the need to extend the theoretical description. PMID:25353815

  13. Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields

    SciTech Connect

    Duckworth, Robert C; Zhang, Yifei; Ha, Tam T; Gouge, Michael J

    2011-01-01

    In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

  14. Frequency characteristics of field electron emission from long carbon nanofilaments/nanotubes in a weak AC electric field

    NASA Astrophysics Data System (ADS)

    Izrael'yants, K. R.; Orlov, A. P.; Musatov, A. L.; Blagov, E. V.

    2016-05-01

    Frequency characteristics of field electron emission from long carbon nanofilaments/nanotubes in strong dc and weak ac electric fields have been investigated. A series of narrow peaks with a quality factor of up to 1100 has been discovered in the frequency range of hundreds of kilohertz. The analysis has shown that these peaks are probably associated with mechanical oscillations of the carbon nanofilaments/nanotubes driven by the ac electric field.

  15. Instrumental Direction-dependent Effects in Wide-field Wide-band Interferometric Imaging

    NASA Astrophysics Data System (ADS)

    Bhatnagar, Sanjay; Rau, U.; Golap, K.

    2014-04-01

    Many next generation radio telescopes, some now in operation, offer significant improvement in the sensitivity and angular resolution compared to the telescopes operated in the past decades. This improvement in sensitivity is achieved with the use of wide-band receivers and larger collecting area. The effects of wide instantaneous fractional bandwidths that classical calibration and imaging algorithms ignore, lead to errors higher than the sensitivity that these new telescopes offer. Examples, relevant for some of the telescopes already in operation include the effects of time and frequency variant primary beams, frequency dependence of the emission from the sky and antenna pointing errors. The effects of wide fractional bandwidth and ionospheric phase screen limit the imaging performance below ~1 GHz. Additionally, significant variations in the shape of the wide-band primary beams (PB) for aperture array telescopes leads to errors of similar magnitude. Corrections for these effects increases the required computing power by many orders of magnitude. Furthermore, both wide fractional bandwidths and larger collecting area lead to many orders of magnitude increase in the data volume also, putting severe constraints on the run-time performance of the algorithms for calibration and imaging. In this talk, I will review the state-of-the-art algorithms for wide-field wide-band imaging and the run-time costs of the different approaches for correction of various direction-dependent effects and discuss the computational challenges in thermal noise-limited wide-field imaging with current and future radio telescopes.

  16. C/NOFS Observations of AC Electric Field Fields Associated with Equatorial Spread-F

    NASA Technical Reports Server (NTRS)

    Pfaff, R.; Liebrecht, C.

    2009-01-01

    The Vector Electric Field Investigation (VEFI) on the C/NOFS equatorial satellite provides a unique data set in which to acquire detailed knowledge of irregularities associated with the equatorial ionosphere and in particular with spread-F depletions. We present vector AC electric field observations, primarily gathered within the ELF band (1 Hz to 250 Hz) on C/NOFS that address a variety of key questions regarding how plasma irregularities, from meter to kilometer scales, are created and evolve. The data will be used to explore the anisotropy/isotropy of the waves, their wavelength and phase velocity, as well as their spectral distributions. When analyzed in conjunction with the driving DC electric fields and detailed plasma number density measurements, the combined data reveal important information concerning the instability mechanisms themselves. We also present high resolution, vector measurements of intense lower hybrid waves that have been detected on numerous occasions by the VEFI burst memory VLF electric field channels.

  17. Optical Design of WFIRST-AFTA Wide-Field Instrument

    NASA Technical Reports Server (NTRS)

    Pasquale, Bert; Content, Dave; Kruk, Jeffrey; Vaughn, David; Gong, Qian; Howard, Joseph; Jurling, Alden; Mentzell, Eric; Armani, Nerses; Kuan, Gary

    2014-01-01

    The WFIRSTAFTA Wide-Field Infrared Survey Telescope TMA optical design provides 0.28-sq FOV at 0.11 pixel scale, operating between 0.6 2.4m, including a spectrograph mode (1.3-1.95m.) An IFU provides a discrete 3x3.15 field at 0.15 sampling.

  18. Production Of Multi-magnetron Plasma By Using Polyphase Ac Glow Discharge In An Improved Multi-pole Magnetic Field

    NASA Astrophysics Data System (ADS)

    Matsumoto, Kazunori; Motoki, Kentaro; Miyamoto, Masahiro; Uetani, Yasuhiro

    1998-10-01

    Effects of an improved multi-pole magnetic field on a plasma production generated by a polyphase ac glow discharge with multiple electrodes have been investigated. Conventional configuration of the multi-pole magnetic filed has been modified to suppress plasma losses at both ends of the chamber due to ExB drift motion. The modified multi-pole magnetic field has enabled us to produce a multiple magnetron-plasma at a considerably low pressure less than mTorr. The low temperature plasma has been widely used as the fine processing technology of a dry etching and as the thin film formation technology of a sputtering coating. Large-scale plasmas which can be generated at a low gas-pressure have been desired for more wider dry etching and greater sputter coating. The purpose of this study is to develop a large-scale and low-cost plasma generator by using a polyphase ac power source with the low frequency. In this session, we will present the experimental result as to a multiple magnetron-plasma generated in the modified twenty-four poles magnetic field by using the twenty-four-phase ac power source with the commercial electric power frequency of 60Hz. The ac power is supplied to twenty-four electrodes which are fixed to the water-cooled chamber-wall through sheet insulators so that the electrodes can be cooled indirectly.

  19. Nonlinear magnetization relaxation of superparamagnetic nanoparticles in superimposed ac and dc magnetic bias fields

    NASA Astrophysics Data System (ADS)

    Titov, Serguey V.; Déjardin, Pierre-Michel; El Mrabti, Halim; Kalmykov, Yuri P.

    2010-09-01

    The nonlinear ac response of the magnetization M(t) of a uniaxially anisotropic superparamagnetic nanoparticle subjected to both ac and dc bias magnetic fields of arbitrary strengths and orientations is determined by averaging Gilbert’s equation augmented by a random field with Gaussian white-noise properties in order to calculate exactly the relevant statistical averages. It is shown that the magnetization dynamics of the uniaxial particle driven by a strong ac field applied at an angle to the easy axis of the particle (so that the axial symmetry is broken) alters drastically leading to different nonlinear effects due to coupling of the thermally activated magnetization reversal mode with the precessional modes of M(t) via the driving ac field.

  20. PERSPECTIVE: Toward a wide-field retinal prosthesis

    NASA Astrophysics Data System (ADS)

    Ameri, Hossein; Ratanapakorn, Tanapat; Ufer, Stefan; Eckhardt, Helmut; Humayun, Mark S.; Weiland, James D.

    2009-06-01

    The purpose of this paper is to present a wide field electrode array that may increase the field of vision in patients implanted with a retinal prosthesis. Mobility is often impaired in patients with low vision, particularly in those with peripheral visual loss. Studies on low vision patients as well as simulation studies on normally sighted individuals have indicated a strong correlation between the visual field and mobility. In addition, it has been shown that an increased visual field is associated with a significant improvement in visual acuity and object discrimination. Current electrode arrays implanted in animals or human vary in size; however, the retinal area covered by the electrodes has a maximum projected visual field of about 10°. We have designed wide field electrode arrays that could potentially provide a visual field of 34°, which may significantly improve the mobility. Tests performed on a mechanical eye model showed that it was possible to fix 10 mm wide flexible polyimide dummy electrode arrays onto the retina using a single retinal tack. They also showed that the arrays could conform to the inner curvature of the eye. Surgeries on an enucleated porcine eye model demonstrated feasibility of implantation of 10 mm wide arrays through a 5 mm eye wall incision.

  1. Inhomogeneous superconductor in an a.c. field: Application to the pseudogap region

    SciTech Connect

    Ovchinnikov, Yu.N.; Kresin, V.Z.

    2002-02-01

    The behavior of an inhomogeneous superconductor in an external a.c. field is studied. General equations describing the a.c. response are formulated. Special attention is paid to the case of a layered conductor containing superconducting ''islands''. A system of this type displays ''pseudogap'' properties. The surface impedance Z is evaluated. It is shown that the ReZ {ne} |ImZ| and their difference {Delta}Z {proportional_to} {omega}{sup -1/2}, {omega} is the frequency of the a.c. field.

  2. Effect of Interfacial Resistance on AC Loss as a Function of Applied AC Field in YBCO Filamentary Conductors

    SciTech Connect

    Duckworth, Robert C; List III, Frederick Alyious; Zhang, Yifei

    2009-01-01

    To reduce ac loss in Y-Ba-Cu-O (YBCO) coated conductors while maintaining current sharing between filaments, an attempt was made to introduce an interfacial resistance between the YBCO filaments and a continuous silver cap layer. The YBCO filaments were produced via laser scribing of MOCVD YBCO films deposited on standard Ion Beam Assisted Deposition (IBAD) templates. After laser scribing, the filaments were exposed to air at room temperature to degrade the YBCO surface. A three micron thick silver cap layer was then and each sample was oxygen annealed at different temperature to produce different interface resistance at the interface between the silver and YBCO. Measurements of the ac loss was measured as a function of applied perpendicular field and frequency revealed a correlation between the reduction in coupling loss and the oxygen annealing temperature.

  3. Magnetic flux penetration into twisted multifilamentary coated superconductors subjected to ac transverse magnetic fields

    NASA Astrophysics Data System (ADS)

    Amemiya, Naoyuki; Sato, Susumu; Ito, Takeshi

    2006-12-01

    ac losses in superconductors are generated by the magnetic flux and current penetration into them. To reveal the magnetic flux and current penetration processes in twisted multifilamentary coated superconductors in which the thin superconductor layer is subdivided into filaments and then twisted as a whole for ac loss reduction, a theoretical model for electromagnetic field analysis was developed based on the power law E-J (electric-field-current-density) characteristic for the superconductor and a thin strip approximation of the conductor. The developed theoretical model was implemented into a numerical code using the finite element method to calculate and visualize the current and magnetic flux distributions. The magnetization losses in twisted multifilamentary coated superconductors exposed to ac transverse magnetic fields were calculated from the temporal evolutions of the current distribution to demonstrate the effect of the twisted multifilamentary architecture on ac loss reduction.

  4. Wide Field and Planetary Camera for Space Telescope

    NASA Technical Reports Server (NTRS)

    Lockhart, R. F.

    1982-01-01

    The Space Telescope's Wide Field and Planetary Camera instrument, presently under construction, will be used to map the observable universe and to study the outer planets. It will be able to see 1000 times farther than any previously employed instrument. The Wide Field system will be located in a radial bay, receiving its signals via a pick-off mirror centered on the optical axis of the telescope assembly. The external thermal radiator employed by the instrument for cooling will be part of the exterior surface of the Space Telescope. In addition to having a larger (1200-12,000 A) wavelength range than any of the other Space Telescope instruments, its data rate, at 1 Mb/sec, exceeds that of the other instruments. Attention is given to the operating modes and projected performance levels of the Wide Field Camera and Planetary Camera.

  5. Calorimetric method of ac loss measurement in a rotating magnetic field.

    PubMed

    Ghoshal, P K; Coombs, T A; Campbell, A M

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-T(c) superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines. PMID:20687748

  6. Calorimetric method of ac loss measurement in a rotating magnetic field

    NASA Astrophysics Data System (ADS)

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-01

    A method is described for calorimetric ac-loss measurements of high-Tc superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  7. Calorimetric method of ac loss measurement in a rotating magnetic field

    SciTech Connect

    Ghoshal, P. K.; Coombs, T. A.; Campbell, A. M.

    2010-07-15

    A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

  8. Wide-Field Sky Monitoring - Optical and X-rays

    NASA Astrophysics Data System (ADS)

    Hudec, R.; BART Teams; Ondrejov Observatory Lobster Eye Team

    We report on selected projects in wide-field sky imaging. This includes the recent efforts to digitize the astronomical sky plate archives and to apply these data for various scientific projects. We also address and discuss the status of the development of related algorithms and software programs. These data may easily provide very long term monitoring over very extended time intervals (up to more than 100 years) with limiting magnitudes between 12 and 23. The further experiments include CCD sky monitors, OMC camera onboard the ESA Integral satellite, robotic telescopes, and innovative wide-field X-ray telescopes.

  9. Paramagnetic shimming for wide-range variable-field NMR.

    PubMed

    Ichijo, Naoki; Takeda, Kazuyuki; Takegoshi, K

    2014-09-01

    We propose a new passive shimming strategy for variable-field NMR experiments, in which the magnetic field produced by paramagnetic shim pieces placed inside the magnet bore compensates the inhomogeneity of a variable-field magnet for a wide range of magnet currents. Paramagnetic shimming is demonstrated in (7)Li, (87)Rb, and (45)Sc NMR of a liquid solution sample in magnetic fields of 3.4, 4.0, and 5.4T at a fixed carrier frequency of 56.0MHz. Since both the main-field inhomogeneity and the paramagnetic magnetization are proportional to the main-magnet current, the resonance lines are equally narrowed by the improved field homogeneity with an identical configuration of the paramagnetic shim pieces. Paramagnetic shimming presented in this work opens the possibility of high-resolution variable-field NMR experiments. PMID:25080372

  10. Analyze and experiment on AC magnetic field's effect to fiber optic gyroscopes in compact stabilization control systems

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Mao, Yao; Tian, Jing; Li, Zhijun

    2015-10-01

    Fiber optic gyroscopes (FOG) are getting more and more attention in areas such as stabilization control systems as they are all solid state and have a wide bandwidth. In stabilization systems that require wide bandwidth control, motors are usually used as actuating mechanism for active disturbance restrain. Voice coil motors (VCMs) are usually used in compact stabilization systems that require large torque and fast response. However, AC magnetic field, which can affect the output of FOG due to Faraday effect, will be generated during operation of VCMs. The frequency range affected by the AC magnetic field to the FOG's output is the same as VCMs drive signal frequency range, which is also exactly the stabilization system's working range. Therefore the effect of the AC magnetic field to FOGs must be evaluated to verify the feasibility of a stable system design that uses both FOGs and VCMs. In this article, the basic structure and operating principle of stabilization system is introduced. The influence of AC magnetic field to FOG is theoretically analyzed. The magnetic field generated by VCMs is numerically simulated based on the theory deduction of the magnetic field near energized wires. To verify the influence of the VCM generated magnetic field to the FOGs in practical designs, a simplified random fiber coil model is built for it's hard to accurately test the exact polarize axis's twisting rate in a fiber coil. The influence to the FOG's output of different random coil model is simulated and the result shows a same trend that the influence of the VCM's magnetic field to the FOG is reduced as the distance between the VCM and the FOG increasing. The influence of a VCM to a FOG with the same parameters is experimentally tested. In the Fourier transformed FOG data the same frequency point as the VCM drive signal frequency can be read. The result fit simulated result that as the distance increases, the influence decreases. The amplitude of the frequency point is just

  11. Approach for Wide Use of Diagnostic Method for XLPE Cables Using Harmonics in AC Loss Current

    NASA Astrophysics Data System (ADS)

    Tsujimoto, Tomiyuki; Nakade, Masahiko; Yagi, Yukihiro; Ishii, Noboru

    Water tree is one of the degradation aspects of XLPE cables used for under-ground distribution or transmission lines. We have developed the loss current method using 3rd harmonic in AC loss current for cable diagnosis. Harmonic components in loss current arise as a result of the non-linear voltage-current characteristics of water trees. We confirmed that the 3rd harmonic in AC loss current had good correlation with water tree growth and break down strength. After that, we have applied this method to the actual 66kV XLPE cable lines. Up to now, the number of the application results is more than 130 lines. In case of cable lines terminated at gas-insulated switchgear (GIS), we have to remove the lightning arrestor (LA) and the potential transformer (PT) out of the test circuit. The reason is that we are afraid that each of LA and PT disturbs the degradation signal from cable lines. It takes extra time (1 or 2 days) and costs more to remove LA and PT in GIS out of a circuit. In order to achieve easy and reasonable diagnosis, we have developed a new method for cable lines terminated at GIS, by utilizing a technique, which enables to reduce signal of LA and PT from disturbed signal of cable lines. We confirmed the effect of the new method by experiments with actual cables.

  12. Electric field in an AC dielectric barrier discharge overlapped with a nanosecond pulse discharge

    NASA Astrophysics Data System (ADS)

    Goldberg, Benjamin M.; Shkurenkov, Ivan; Adamovich, Igor V.; Lempert, Walter R.

    2016-08-01

    The effect of ns discharge pulses on the AC barrier discharge in hydrogen in plane-to-plane geometry is studied using time-resolved measurements of the electric field in the plasma. The AC discharge was operated at a pressure of 300 Torr at frequencies of 500 and 1750 Hz, with ns pulses generated when the AC voltage was near zero. The electric field vector is measured by ps four-wave mixing technique, which generates coherent IR signal proportional to the square of electric field. Absolute calibration was done using an electrostatic (sub-breakdown) field applied to the discharge electrodes, when no plasma was generated. The results are compared with one-dimensional kinetic modeling of the AC discharge and the nanosecond pulse discharge, predicting behavior of both individual micro-discharges and their cumulative effect on the electric field distribution in the electrode gap, using stochastic averaging based on the experimental micro-discharge temporal probability distribution during the AC period. Time evolution of the electric field in the AC discharge without ns pulses, controlled by a superposition of random micro-discharges, exhibits a nearly ‘flat top’ distribution with the maximum near breakdown threshold, reproduced quite well by kinetic modeling. Adding ns pulse discharges on top of the AC voltage waveform changes the AC discharge behavior in a dramatic way, inducing transition from random micro-discharges to a more regular, near-1D discharge. In this case, reproducible volumetric AC breakdown is produced at a well-defined moment after each ns pulse discharge. During the reproducible AC breakdown, the electric field in the plasma exhibits a sudden drop, which coincides in time with a well-defined current pulse. This trend is also predicted by the kinetic model. Analysis of kinetic modeling predictions shows that this effect is caused by large-volume ionization and neutralization of surface charges on the dielectrics by ns discharge pulses. The present

  13. Wide-Field MAXI - Wide-Field Soft X-ray Transient Monitor on the ISS

    NASA Astrophysics Data System (ADS)

    Kawai, Nobuyuki

    WF-MAXI is a mission to detect and localize X-ray transients including GRBs and XRFs, X-ray binaries, and hopefully tidal disruption events and supernova shockbreakouts. We are designing WF-MAXI to be ready for the initial operational phase of the next generation GW telescopes: Adv-LIGO, VIRGO and KAGRA, which are expected to be operational in 2-4 years. It will be sensitive to soft extended emission of short GRBs. It will also succeed the current MAXI mission, which is providing alerts for outbursts of X-ray sources to the community. We chose to use flight-proven or qualified technologies developed for MAXI, ASTRO-H, and TSUBAME for a fast development of the mission. The main instrument is Soft X-ray Large-sky Cameras (SLC), pairs of criss-cross coded aperture cameras using CCD as one-dimensional fast-readout detectors covering 20% of the sky in the 0.7-12 keV band. The Hard X-ray Monitor share the same field as SLC in the hard X-ray band. We are proposing this mission for the ISS/JEM AO in this year aiming to start operations in 2018.

  14. Study of effect of AC and DC magnetic fields on growth of Pisum sativum seeds

    NASA Astrophysics Data System (ADS)

    Bahar, Mahmood; Yasaie Mehrjardi, Yasaman; Sojoodi, Jaleh; Bayani, Hosien; Kazem Salem, Mohammad

    2013-08-01

    This paper concentrates on the effect of the AC and DC magnetic fields on plant growth. The effect of AC magnetic field with intensities of 2.25, 1.66 and 1.49 mT and DC magnetic field with intensities of 3.6, 2.41 and 2.05 mT in exposure durations of 2, 4, 6, 8, 10 and 12 min on two groups of dry and wet Pisum sativum seedlings was studied. In each experiment 10 seeds were used; the experiments were repeated three times for each group and there was a sham exposed group for comparison purposes. The light cycle was 12 h light/12 h darkness and the temperature was 25 ± 1° C. The index of growth is considered to be the root and stem elongation on the sixth day. It was observed that AC magnetic field has a positive effect on the growth in all durations and intensities. Moreover, it is highlighted that during the experiments, the mean growth of dry seedlings significantly increased by a factor of 11 in AC magnetic field with the lowest intensity of 1.49 mT (p < 0.05). It was also shown that AC magnetic fields had a more positive effect on the growth of plants in comparison to DC magnetic fields.

  15. Acquisition of Cry1Ac Protein by Non-Target Arthropods in Bt Soybean Fields

    PubMed Central

    Yu, Huilin; Romeis, Jörg; Li, Yunhe; Li, Xiangju; Wu, Kongming

    2014-01-01

    Soybean tissue and arthropods were collected in Bt soybean fields in China at different times during the growing season to investigate the exposure of arthropods to the plant-produced Cry1Ac toxin and the transmission of the toxin within the food web. Samples from 52 arthropod species/taxa belonging to 42 families in 10 orders were analysed for their Cry1Ac content using enzyme-linked immunosorbent assay (ELISA). Among the 22 species/taxa for which three samples were analysed, toxin concentration was highest in the grasshopper Atractomorpha sinensis and represented about 50% of the concentration in soybean leaves. Other species/taxa did not contain detectable toxin or contained a concentration that was between 1 and 10% of that detected in leaves. These Cry1Ac-positive arthropods included a number of mesophyll-feeding Hemiptera, a cicadellid, a curculionid beetle and, among the predators, a thomisid spider and an unidentified predatory bug belonging to the Anthocoridae. Within an arthropod species/taxon, the Cry1Ac content sometimes varied between life stages (nymphs/larvae vs. adults) and sampling dates (before, during, and after flowering). Our study is the first to provide information on Cry1Ac-expression levels in soybean plants and Cry1Ac concentrations in non-target arthropods in Chinese soybean fields. The data will be useful for assessing the risk of non-target arthropod exposure to Cry1Ac in soybean. PMID:25110881

  16. Acquisition of Cry1Ac protein by non-target arthropods in Bt soybean fields.

    PubMed

    Yu, Huilin; Romeis, Jörg; Li, Yunhe; Li, Xiangju; Wu, Kongming

    2014-01-01

    Soybean tissue and arthropods were collected in Bt soybean fields in China at different times during the growing season to investigate the exposure of arthropods to the plant-produced Cry1Ac toxin and the transmission of the toxin within the food web. Samples from 52 arthropod species/taxa belonging to 42 families in 10 orders were analysed for their Cry1Ac content using enzyme-linked immunosorbent assay (ELISA). Among the 22 species/taxa for which three samples were analysed, toxin concentration was highest in the grasshopper Atractomorpha sinensis and represented about 50% of the concentration in soybean leaves. Other species/taxa did not contain detectable toxin or contained a concentration that was between 1 and 10% of that detected in leaves. These Cry1Ac-positive arthropods included a number of mesophyll-feeding Hemiptera, a cicadellid, a curculionid beetle and, among the predators, a thomisid spider and an unidentified predatory bug belonging to the Anthocoridae. Within an arthropod species/taxon, the Cry1Ac content sometimes varied between life stages (nymphs/larvae vs. adults) and sampling dates (before, during, and after flowering). Our study is the first to provide information on Cry1Ac-expression levels in soybean plants and Cry1Ac concentrations in non-target arthropods in Chinese soybean fields. The data will be useful for assessing the risk of non-target arthropod exposure to Cry1Ac in soybean. PMID:25110881

  17. Wide-Field Raman Imaging of Dental Lesions

    PubMed Central

    Yang, Shan; Li, Bolan; Akkus, Anna; Akkus, Ozan; Lang, Lisa

    2014-01-01

    Detection of dental caries at the onset remains as a great challenge in dentistry. Raman spectroscopy could be successfully applied towards detecting caries since it is sensitive to the amount of the Raman active mineral crystals, the most abundant component of enamel. Effective diagnosis requires full examination of a tooth surface via a Raman mapping. Point-scan Raman mapping is not clinically relevant (feasible) due to lengthy data acquisition time. In this work, a wide-field Raman imaging system was assembled based on a high-sensitivity 2D CCD camera for imaging the mineralization status of teeth with lesions. Wide-field images indicated some lesions to be hypomineralized and others to be hypermineralized. The observations of wide-field Raman imaging were in agreement with point-scan Raman mapping. Therefore, sound enamel and lesions can be discriminated by Raman imaging of the mineral content. In conclusion, wide-field Raman imaging is a potentially useful tool for visualization of dental lesions in the clinic. PMID:24781363

  18. Michelson wide-field stellar interferometry: principles and experimental verification.

    PubMed

    Montilla, I; Pereira, S F; Braat, J J M

    2005-01-20

    A new interferometric technique for Michelson wide-field interferometry is presented that consists of a Michelson pupil-plane combination scheme in which a wide field of view can be achieved in one shot. This technique uses a stair-shaped mirror in the intermediate image plane of each telescope in the array, allowing for simultaneous correction of the differential delay for the on-axis and off-axis image positions. Experimental results in a laboratory setup show that it is possible to recover the fringes of on-axis and off-axis stars with an angular separation of 1 arc min simultaneously and with a similar contrast. This new technique represents a considerable extension of the field of view of an interferometer without the need for extra observation time. PMID:15717821

  19. Miniature wide field-of-view star trackers for spacecraft attitude sensing and navigation

    NASA Technical Reports Server (NTRS)

    Mccarty, William; Curtis, Eric; Hull, Anthony; Morgan, William

    1993-01-01

    Introducing a family of miniature, wide field-of-view star trackers for low cost, high performance spacecraft attitude determination and navigation applications. These devices, derivative of the WFOV Star Tracker Camera developed cooperatively by OCA Applied Optics and the Lawrence Livermore National Laboratory for the Brilliant Pebbles program, offer a suite of options addressing a wide range of spacecraft attitude measurement and control requirements. These sensors employ much wider fields than are customary (ranging between 20 and 60 degrees) to assure enough bright stars for quick and accurate attitude determinations without long integration intervals. The key benefit of this approach are light weight, low power, reduced data processing loads and high information carrier rates for wide ACS bandwidths. Devices described range from the proven OCA/LLNL WFOV Star Tracker Camera (a low-cost, space-qualified star-field imager utilizing the spacecraft's own computer and centroiding and position-finding), to a new autonomous subsystem design featuring dual-redundant cameras and completely self-contained star-field data processing with output quaternion solutions accurate to 100 micro-rad, 3 sigma, for stand-alone applications.

  20. Efficacy of an AC sinusoidal electric field for apoptosis induction in lung carcinoma cells (A549)

    NASA Astrophysics Data System (ADS)

    Park, Hyoun-Hyang; Lee, Seung S.; Hoon Lee, Dae

    2012-08-01

    An AC sinusoidal electric field was applied to lung carcinoma cells for the induction of apoptosis. The occurrence of apoptosis was determined by analysis of Annexin V/PI and DNA fragmentation. Additional evidence of apoptosis was confirmed by caspase-3 cleavage and disruption of mitochondrial membrane potential. These results demonstrated that the expression of apoptosis can be controlled by varying the magnitude and the duration of the field, and that the application of an AC electric field can stimulate the apoptosis via mitochondria-mediated pathway.

  1. High-Resolution ac Measurements of the Hall Effect in Organic Field-Effect Transistors

    NASA Astrophysics Data System (ADS)

    Chen, Y.; Yi, H. T.; Podzorov, V.

    2016-03-01

    We describe a high resolving power technique for Hall-effect measurements, efficient in determining Hall mobility and carrier density in organic field-effect transistors and other low-mobility systems. We utilize a small low-frequency ac magnetic field (Brms<0.25 T ) and a phase-sensitive (lock-in) detection of Hall voltage, with the necessary corrections for Faraday induction. This method significantly enhances the signal-to-noise ratio and eliminates the necessity of using high magnetic fields in Hall-effect studies. With the help of this method, we are able to obtain the Hall mobility and carrier density in organic transistors with a mobility as low as μ ˜0.3 cm2 V-1 s-1 by using a compact desktop apparatus and low magnetic fields. We find a good agreement between Hall-effect and electric-field-effect measurements, indicating that, contrary to the common belief, certain organic semiconductors with mobilities below 1 cm2 V-1 s-1 can still exhibit a fully developed, band-semiconductor-like Hall effect, with the Hall mobility and carrier density matching those obtained in longitudinal transistor measurements. This suggests that, even when μ <1 cm2 V-1 s-1 , charges in organic semiconductors can still behave as delocalized coherent carriers. This technique paves the way to ubiquitous Hall-effect studies in a wide range of low-mobility materials and devices, where it is typically very difficult to resolve the Hall effect even in very high dc magnetic fields.

  2. Wide-field in vivo oral OCT imaging

    PubMed Central

    Lee, Anthony M. D.; Cahill, Lucas; Liu, Kelly; MacAulay, Calum; Poh, Catherine; Lane, Pierre

    2015-01-01

    We have built a polarization-sensitive swept source Optical Coherence Tomography (OCT) instrument capable of wide-field in vivo imaging in the oral cavity. This instrument uses a hand-held side-looking fiber-optic rotary pullback catheter that can cover two dimensional tissue imaging fields approximately 2.5 mm wide by up to 90 mm length in a single image acquisition. The catheter spins at 100 Hz with pullback speeds up to 15 mm/s allowing imaging of areas up to 225 mm2 field-of-view in seconds. A catheter sheath and two optional catheter sheath holders have been designed to allow imaging at all locations within the oral cavity. Image quality of 2-dimensional image slices through the data can be greatly enhanced by averaging over the orthogonal dimension to reduce speckle. Initial in vivo imaging results reveal a wide-field view of features such as epithelial thickness and continuity of the basement membrane that may be useful in clinic for chair-side management of oral lesions. PMID:26203389

  3. Calorimetric AC loss measurement of MgB2 superconducting tape in an alternating transport current and direct magnetic field

    NASA Astrophysics Data System (ADS)

    See, K. W.; Xu, X.; Horvat, J.; Cook, C. D.; Dou, S. X.

    2012-11-01

    Applications of MgB2 superconductors in electrical engineering have been widely reported, and various studies have been made to define their alternating current (AC) losses. However, studies on the transport losses with an applied transverse DC magnetic field have not been conducted, even though this is one of the favored conditions in applications of practical MgB2 tapes. Methods and techniques used to characterize and measure these losses have so far been grouped into ‘electrical’ and ‘calorimetric’ approaches with external conditions set to resemble the application conditions. In this paper, we present a new approach to mounting the sample and employ the calorimetric method to accurately determine the losses in the concurrent application of AC transport current and DC magnetic fields that are likely to be experienced in practical devices such as generators and motors. This technique provides great simplification compared to the pickup coil and lock-in amplifier methods and is applied to a long length (˜10 cm) superconducting tape. The AC loss data at 20 and 30 K will be presented in an applied transport current of 50 Hz under external DC magnetic fields. The results are found to be higher than the theoretical predictions because of the metallic fraction of the tape that contributes quite significantly to the total losses. The data, however, will allow minimization of losses in practical MgB2 coils and will be used in the verification of numerical coil models.

  4. Wide band fiber Bragg grating accelerometer for rotating AC machinery condition monitoring

    NASA Astrophysics Data System (ADS)

    Vilchis-Rodriguez, Damian S.; Djurovic, Sinisa; Kung, Peter; Comanici, Maria I.; Scepanovic, S.; Tshiloz, Kavul; Smith, Alexander C.

    2014-09-01

    This paper investigates the use of fiber Bragg grating (FBG) accelerometers for wide band vibration monitoring in a wound rotor induction generator. The sensor performance is assessed in a series of experiments on a laboratory test rig comprising a 30kW induction machine operating under steady state and variable speed regimes. Vibration measurements are investigated in the frequency domain for generator fault specific electromagnetically induced vibration components. The fiber optic sensor effectiveness in detection of wide band spectral effects (<1kHz) in the vibration signal is compared with that of a commercial piezoelectric based solution. The potential and limitations of the prototype wide band FBG accelerometer are evaluated for use in vibration monitoring applications.

  5. Field of Bachelor's Degree in the United States: 2009. American Community Survey Reports. ACS-18

    ERIC Educational Resources Information Center

    Siebens, Julie; Ryan, Camille L.

    2012-01-01

    This report provides information on fields of bachelor's degrees in the United States using data from the 2009 American Community Survey (ACS). It includes estimates of fields of bachelor's degree by demographic characteristics including age, sex, race, Hispanic origin, nativity, and educational attainment. This report also looks at geographic and…

  6. Satellite Detection in AdvancedCamera for Surveys/Wide Field Channel Images

    NASA Astrophysics Data System (ADS)

    Borncamp, D.; Lim, Pey-Lian

    2016-01-01

    This document explains the process by which satellite trails can be found within individual chips of an Advanced Camera for Surveys (ACS) Wide Field Channel (WFC) image. Since satellites are transient and sporadic events, we used the Hubble Frontier Fields (HFF) dataset which is manually checked for satellite trails has been used as a truth set to verify that the method in this document does a complete job without a high false positive rate. This document also details the process of producing a mask that will update data quality information to inform users where the trail traverses the image and properly account for the affected pixels. Along with this document, the Python source code used to detect and mask satellite trails will be released to users with as a stand-alone product within the STSDAS acstools package.

  7. Science with the Second Wide Field and Planetary Camera

    NASA Astrophysics Data System (ADS)

    Trauger, J.

    1992-07-01

    With the commencement of Cycle 4 observations, the General Observor community will have access to the second Wide Field and Planetary Camera (WFPC2), a replacement for the orginal WFPC instrument. WFPC2, a wide-field photometric camera which covers the spectrum from 12000 to 10000 Angstroms, will be installed in the Hubble radial bay during the currently manifested December 1993 Shuttle servicing mission. Besides optical correction for the aberrated Hubble primary mirror, the WFPC2 incorporates evolutionary improvement in photometric imaging capabilities. The CCD sensors, signal chain electronics, filter set, FUV performance, internal calibrations, and operational efficiency have all been improved through new technologies and lessons learned from WFPC operations and Hubble experience since launch. Here we provide an overview of the new instrument, beginning with the assumption that the reader is already familiar with the original WFPC now in service.

  8. A wide-field soft X-ray camera

    NASA Technical Reports Server (NTRS)

    Petre, R.

    1981-01-01

    A wide-field soft X-ray camera (WFSXC) sensitive in the 50 to 250 eV band is described. The camera features Wolter-Schwarzschild optics with an 8 degree field of view and 300 cu cu collecting area. The focal plane instrument is a microchannel plate detector. Broad-band energy discrimination is provided by thin-film filters mounted immediately in front of the focal plane. The WFSXC is capable of detecting sources with intensities greater than 5 percent of HZ 43 during typical sounding rocket exposures, and it would approach the same sensitivity range as EUVE during a typical exposure from the Shuttle.

  9. Time Delay Integration: A Wide-Field Survey Technique

    NASA Astrophysics Data System (ADS)

    Lapointe, Robert; Hill, E.; Leimer, L.; McMillian, K.; Miller, A.; Prindle, A.

    2009-05-01

    The Advanced Placement Physics class of Orange Lutheran High School has conducted a survey-imaging pro-ject using a Time Delay Integration (TDI) technique. TDI enables very wide-field images to be collected in the form of long strips of the sky. A series of five consecutive nights were captured, calibrated and compared to re-veal possible transient phenomena such as supernovae, asteroids, and other events that have a noticeable change over 24-hour intervals.

  10. In-Flight Performance of Wide Field Camera 3

    NASA Technical Reports Server (NTRS)

    Kimble, Randy

    2010-01-01

    Wide Field Camera 3 (WFC3), a powerful new UVNisible/IR imager, was installed into HST during Servicing Mission 4. After a successful commissioning in the Servicing Mission Orbital Verification program, WFC3 has been engaged in an exciting program of scientific observations. I review here the in-flight scientific performance of the instrument, addressing such topics as image quality, sensitivity, detector performance, and stability.

  11. High-Resolution, Wide-Field-of-View Scanning Telescope

    NASA Technical Reports Server (NTRS)

    Sepulveda, Cesar; Wilson, Robert; Seshadri, Suresh

    2007-01-01

    A proposed telescope would afford high resolution over a narrow field of view (<0.10 ) while scanning over a total field of view nominally 16 wide without need to slew the entire massive telescope structure. The telescope design enables resolution of a 1-m-wide object in a 50- km-wide area of the surface of the Earth as part of a 200-km-wide area field of view monitored from an orbit at an altitude of 700 km. The conceptual design of this telescope could also be adapted to other applications both terrestrial and extraterrestrial in which there are requirements for telescopes that afford both wide- and narrow-field capabilities. In the proposed telescope, the scanning would be effected according to a principle similar to that of the Arecibo radio telescope, in which the primary mirror is stationary with respect to the ground and a receiver is moved across the focal surface of the primary mirror. The proposed telescope would comprise (1) a large spherical primary mirror that would afford high resolution over a narrow field of view and (2) a small displaceable optical relay segment that would be pivoted about the center of an aperture stop to effect the required scanning (see figure). Taken together, both comprise a scanning narrow-angle telescope that does not require slewing the telescope structure. In normal operation, the massive telescope structure would stare at a fixed location on the ground. The inner moveable relay optic would be pivoted to scan the narrower field of view over the wider one, making it possible to retain a fixed telescope orientation, while obtaining high-resolution images over multiple target areas during an interval of 3 to 4 minutes in the intended orbit. The pivoting relay segment of the narrow-angle telescope would include refractive and reflective optical elements, including two aspherical mirrors, to counteract the spherical aberration of the primary mirror. Overall, the combination of the primary mirror and the smaller relay optic

  12. Physical aspects of magnetic hyperthermia: Low-frequency ac field absorption in a magnetic colloid

    NASA Astrophysics Data System (ADS)

    L. Raikher, Yu.; Stepanov, V. I.

    2014-11-01

    A uniaxially anisotropic superparamagnetic particle suspended in a viscous fluid and subjected to an ac field is considered. Consistently taking into account both internal (Néel) and external (Brownian) magnetic relaxations, a simple expression for the dynamic susceptibility is obtained. This result, with regard to the ac field energy absorption, is compared to the common heuristic approach. This is done for a model polydisperse colloid containing maghemite nanoparticles, which are assumed to posses either bulk or surface magnetic anisotropy. It is shown that viscous losses caused by the particle motion in a fluid matrix make important contribution to the full magnetic response of a ferrocolloid and, thus, its ability to absorb the ac field energy. The obtained exact expression, which takes in both dissipation mechanisms, paves the way to correct optimization of the nanoparticle-mediated heating effect.

  13. Encouragement of Enzyme Reaction Utilizing Heat Generation from Ferromagnetic Particles Subjected to an AC Magnetic Field

    PubMed Central

    Suzuki, Masashi; Aki, Atsushi; Mizuki, Toru; Maekawa, Toru; Usami, Ron; Morimoto, Hisao

    2015-01-01

    We propose a method of activating an enzyme utilizing heat generation from ferromagnetic particles under an ac magnetic field. We immobilize α-amylase on the surface of ferromagnetic particles and analyze its activity. We find that when α-amylase/ferromagnetic particle hybrids, that is, ferromagnetic particles, on which α-amylase molecules are immobilized, are subjected to an ac magnetic field, the particles generate heat and as a result, α-amylase on the particles is heated up and activated. We next prepare a solution, in which α-amylase/ferromagnetic particle hybrids and free, nonimmobilized chitinase are dispersed, and analyze their activities. We find that when the solution is subjected to an ac magnetic field, the activity of α-amylase immobilized on the particles increases, whereas that of free chitinase hardly changes; in other words, only α-amylase immobilized on the particles is selectively activated due to heat generation from the particles. PMID:25993268

  14. Quantitative phase imaging by wide field lensless digital holographic microscope

    NASA Astrophysics Data System (ADS)

    Adinda-Ougba, A.; Koukourakis, N.; Essaidi, A.; Ger­hardt, N. C.; Hofmann, M. R.

    2015-05-01

    Wide field, lensless microscopes have been developed for telemedicine and for resource limited setting [1]. They are based on in-line digital holography which is capable to provide amplitude and phase information resulting from numerical reconstruction. The phase information enables achieving axial resolution in the nanometer range. Hence, such microscopes provide a powerful tool to determine three-dimensional topologies of microstructures. In this contribution, a compact, low-cost, wide field, lensless microscope is presented, which is capable of providing topological profiles of microstructures in transparent material. Our setup consist only of two main components: a CMOSsensor chip and a laser diode without any need of a pinhole. We use this very simple setup to record holograms of microobjects. A wide field of view of ~24 mm², and a lateral resolution of ~2 μm are achieved. Moreover, amplitude and phase information are obtained from the numerical reconstruction of the holograms using a phase retrieval algorithm together with the angular spectrum propagation method. Topographic information of highly transparent micro-objects is obtained from the phase data. We evaluate our system by recording holograms of lines with different depths written by a focused laser beam. A reliable characterization of laser written microstructures is crucial for their functionality. Our results show that this system is valuable for determination of topological profiles of microstructures in transparent material.

  15. Wide Integral Field Infrared Spectroscopic Survey of Nearby Galaxies

    NASA Astrophysics Data System (ADS)

    Sivanandam, Suresh; Moon, Dae-Sik; Zaritsky, Dennis F.; Chou, Richard; Meyer, Elliot; Ma, Ke; Jarvis, Miranda; Eisner, Joshua A.

    2015-01-01

    We are constructing a novel infrared integral field spectrograph with a large field of view (~50'x20') that will be available on the Kitt Peak 90' Bok telescope this spring. This wide integral field infrared spectrograph (WIFIS) operates over two wavelength ranges, zJ-band (0.9-1.35 microns) and H-band (1.5-1.8 microns), and has moderate spectral resolving power, 3,000 in zJ-band and 2,200 in H-band, respectively. WIFIS' field-of-view is comparable to current optical integral field spectrographs that are carrying out large galaxy surveys, e.g. SAMI, CALIFA, and MaNGA. We are designing a large nearby galaxy survey to complement the data already been taken by these optical integral field spectroscopic surveys. The near-infrared window provides a sensitive probe of the initial mass functions of stellar populations, the OB stellar fractions in massive star forming regions, and the kinematics of and obscured star formation within merging systems. This will be the first large scale infrared integral field spectroscopic survey of nearby galaxies.

  16. The development of WIFIS: a wide integral field infrared spectrograph

    NASA Astrophysics Data System (ADS)

    Sivanandam, Suresh; Chou, Richard C. Y.; Moon, Dae-Sik; Ma, Ke; Millar-Blanchaer, Maxwell; Eikenberry, Stephen S.; Chun, Moo-Young; Kim, Sang Chul; Raines, Steven N.; Eisner, Joshua

    2012-09-01

    We present the current results from the development of a wide integral field infrared spectrograph (WIFIS). WIFIS offers an unprecedented combination of etendue and spectral resolving power for seeing-limited, integral field observations in the 0.9 - 1.8 μm range and is most sensitive in the 0.9 - 1.35 μ,m range. Its optical design consists of front-end re-imaging optics, an all-reflective image slicer-type, integral field unit (IFU) called FISICA, and a long-slit grating spectrograph back-end that is coupled with a HAWAII 2RG focal plane array. The full wavelength range is achieved by selecting between two different gratings. By virtue of its re-imaging optics, the spectrograph is quite versatile and can be used at multiple telescopes. The size of its field-of-view is unrivalled by other similar spectrographs, offering a 4.511x 1211 integral field at a 10-meter class telescope (or 2011 x 5011 at a 2.3-meter telescope). The use of WIFIS will be crucial in astronomical problems which require wide-field, two-dimensional spectroscopy such as the study of merging galaxies at moderate redshift and nearby star/planet-forming regions and supernova remnants. We discuss the final optical design of WIFIS, and its predicted on-sky performance on two reference telescope platforms: the 2.3-m Steward Bok telescope and the 10.4-m Gran Telescopio Canarias. We also present the results from our laboratory characterization of FISICA. IFU properties such as magnification, field-mapping, and slit width along the entire slit length were measured by our tests. The construction and testing of WIFIS is expected to be completed by early 2013. We plan to commission the instrument at the 2.3-m Steward Bok telescope at Kitt Peak, USA in Spring 2013.

  17. Calibrating Wide Field Channel Imagery for the Post-SM4 Advanced Camera for Surveys

    NASA Astrophysics Data System (ADS)

    Armstrong, Amber; Grogin, N.; Lim, P.; Golimowski, D.; Smith, L.

    2011-01-01

    The Wide Field Channel detector of the Advanced Camera for Surveys on board the Hubble Space Telescope was restored to operation during HST Servicing Mission 4 in May 2009. With new control electronics and almost nine years in low Earth orbit, the ACS WFC presents a variety of calibration challenges both old and new. These include mode-dependent bias gradients, bias striping noise, bad columns, cold columns, hot pixels, bad pixels, "scarring,” read-out amplifier crosstalk, and substantial charge-transfer inefficiency. Fortunately, most of these detector irregularities are already corrected or flagged by the existing ACS WFC calibration pipeline, designed prior to the WFC failure. However, our close inspection of post-SM4 calibration images, including bias frames, dark exposures, and astronomical reference fields has motivated us to modernize the WFC calibration pipeline so that we may continue to deliver images of the highest possible quality to the HST observer. We provide a quantitative summary of the various post-SM4 WFC image calibration issues, as well as our strategies for addressing them both within the automated calibration pipeline and outside the pipeline as optional stand-alone calibration utilities available to the HST user community.

  18. The Wide-Field Imager for Solar Probe Plus (WISPR)

    NASA Astrophysics Data System (ADS)

    Vourlidas, Angelos; Howard, Russell A.; Plunkett, Simon P.; Korendyke, Clarence M.; Thernisien, Arnaud F. R.; Wang, Dennis; Rich, Nathan; Carter, Michael T.; Chua, Damien H.; Socker, Dennis G.; Linton, Mark G.; Morrill, Jeff S.; Lynch, Sean; Thurn, Adam; Van Duyne, Peter; Hagood, Robert; Clifford, Greg; Grey, Phares J.; Velli, Marco; Liewer, Paulett C.; Hall, Jeffrey R.; DeJong, Eric M.; Mikic, Zoran; Rochus, Pierre; Mazy, Emanuel; Bothmer, Volker; Rodmann, Jens

    2015-02-01

    The Wide-field Imager for Solar PRobe Plus (WISPR) is the sole imager aboard the Solar Probe Plus (SPP) mission scheduled for launch in 2018. SPP will be a unique mission designed to orbit as close as 7 million km (9.86 solar radii) from Sun center. WISPR employs a 95∘ radial by 58∘ transverse field of view to image the fine-scale structure of the solar corona, derive the 3D structure of the large-scale corona, and determine whether a dust-free zone exists near the Sun. WISPR is the smallest heliospheric imager to date yet it comprises two nested wide-field telescopes with large-format (2 K × 2 K) APS CMOS detectors to optimize the performance for their respective fields of view and to minimize the risk of dust damage, which may be considerable close to the Sun. The WISPR electronics are very flexible allowing the collection of individual images at cadences up to 1 second at perihelion or the summing of multiple images to increase the signal-to-noise when the spacecraft is further from the Sun. The dependency of the Thomson scattering emission of the corona on the imaging geometry dictates that WISPR will be very sensitive to the emission from plasma close to the spacecraft in contrast to the situation for imaging from Earth orbit. WISPR will be the first `local' imager providing a crucial link between the large-scale corona and the in-situ measurements.

  19. Fiber - Optic Devices as Temperature Sensors for Temperature Measurements in AC Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Rablau, Corneliu; Lafrance, Joseph; Sala, Anca

    2007-10-01

    We report on the investigation of several fiber-optic devices as potential sensors for temperature measurements in AC magnetic fields. Common temperature sensors, such as thermocouples, thermistors or diodes, will create random and/or systematic errors when placed in a magnetic field. A DC magnetic field is susceptible to create a systematic offset to the measurement, while in an AC magnetic field of variable frequency random errors which cannot be corrected for can also be introduced. Fiber-Bragg-gratings and thin film filters have an inherent temperature dependence. Detrimental for their primary applications, the same dependence allows one to use such devices as temperature sensors. In an AC magnetic field, they present the advantage of being immune to electromagnetic interference. Moreover, for fiber-Bragg-gratings, the shape factor and small mass of the bare-fiber device make it convenient for temperature measurements on small samples. We studied several thin-film filters and fiber-Bragg-gratings and compared their temperature measurement capabilities in AC magnetic fields of 0 to 150 Gauss, 0 to 20 KHz to the results provided by off-the-shelf thermocouples and thermistor-based temperature measurement systems.

  20. Dynamic speckle illumination wide-field reflection phase microscopy

    PubMed Central

    Choi, Youngwoon; Hosseini, Poorya; Choi, Wonshik; Dasari, Ramachandra R.; So, Peter T. C.; Yaqoob, Zahid

    2014-01-01

    We demonstrate a quantitative reflection-phase microscope based on time-varying speckle-field illumination. Due to the short spatial coherence length of the speckle field, the proposed imaging system features superior lateral resolution, 520 nm, as well as high-depth selectivity, 1.03 µm. Off-axis interferometric detection enables wide-field and single-shot imaging appropriate for high-speed measurements. In addition, the measured phase sensitivity of this method, which is the smallest measurable axial motion, is more than 40 times higher than that available using a transmission system. We demonstrate the utility of our method by successfully distinguishing the motion of the top surface from that of the bottom in red blood cells. The proposed method will be useful for studying membrane dynamics in complex eukaryotic cells. PMID:25361156

  1. Wide-field surveys from the SNAP mission

    SciTech Connect

    agkim@lbl.gov

    2002-07-23

    The Supernova/Acceleration Probe (SNAP) is a proposed space-borne observatory that will survey the sky with a wide-field optical/NIR imager. The images produced by SNAP will have an unprecedented combination of depth, solid-angle, angular resolution, and temporal sampling. Two 7.5 square-degree fields will be observed every four days over 16 months to a magnitude depth of AB = 27.7 in each of nine filters. Co-adding images over all epochs will give an AB = 30.3 per filter. A 300 square-degree field will be surveyed with no repeat visits to AB = 28 per filter. The nine filters span 3500-17000 {angstrom}. Although the survey strategy is tailored for supernova and weak gravitational lensing observations, the resulting data supports a broad range of auxiliary science programs.

  2. Design of a robust modulation controller over a wide range of load characteristics for ac/dc systems

    SciTech Connect

    Choudry, M.A.; Reza, M.A. . Dept. of Electrical Engineering); Ellithy, K.A. )

    1990-02-01

    This paper presents a method to design a robust modulation controller to improve the dynamic performance of ac/dc systems. Static load is modeled as a nonlinear function of load bus voltage and dynamic load is modeled by an equivalent induction motor. Reactive power and dc power are considered for the modulation control. Static var compensator (SVC) is used for the reactive power modulation. The rotor speed and angle deviations of the synchronous generator are used as a stabilizing signal to the SVC. The controller gains are selected based on the eigenvalue sensitivity of electromechanical mode of the closed loop system with respect to load characteristic. Eigenvalue analysis and simulation results show that the proposed reactive power modulation control improves the system response over a wide range of voltage dependent load characteristic as compared with the control using only the rotor speed deviation.

  3. ACS Flat Field Corrections from Observations of 47 Tucanae

    NASA Astrophysics Data System (ADS)

    Mack, J.; Bohlin, R. C.; Gilliland, R. L.; van der Marel, R.; Blakeslee, J. P.; de Marchi, G.

    2002-12-01

    The uniformity of the WFC and HRC detector response has been assessed using multiple dithered pointings of 47 Tucanae. By placing the same stars over different portions of the detector and measuring relative changes in brightness, low frequency spatial variations in the response of each detector have been measured. The original WFC and HRC laboratory flat fields produce photometric errors of 5 to 18 percent from corner-to-corner. The required low-order correction (L-flat) has been applied to the lab flats, and new flat fields have been delivered for use in the calibration pipeline. Initial results suggest the photometric response for a given star is now the same to 1 for any position in the field of view. As a further test, the improved flat fields are compared with observations of the bright earth at UV wavelengths (F330W) and with skyflats from ERO data at long wavelengths (F775W).

  4. The Wide Field Spectrograph (WiFeS)

    NASA Astrophysics Data System (ADS)

    Dopita, Michael; Hart, John; McGregor, Peter; Oates, Patrick; Bloxham, Gabe; Jones, Damien

    2007-08-01

    This paper describes the Wide Field Spectrograph (WiFeS) under construction at the Research School of Astronomy and Astrophysics (RSAA) of the Australian National University (ANU) for the ANU 2.3 m telescope at the Siding Spring Observatory. WiFeS is a powerful integral field, double-beam, concentric, image-slicing spectrograph designed to deliver excellent throughput, wavelength stability, spectrophotometric performance and superb image quality along with wide spectral coverage throughout the 320 950 nm wavelength region. It provides a 25×38 arcsec field with 0.5 arcsec sampling along each of twenty five 38×1 arcsec slitlets. The output format is optimized to match the 4096×4096 pixel CCD detectors in each of two cameras individually optimized for the blue and the red ends of the spectrum, respectively. A process of “interleaved nod-and-shuffle” will be applied to permit quantum noise-limited sky subtraction. Using VPH gratings, spectral resolutions of 3000 and 7000 are provided. The full spectral range is covered in a single exposure at R=3000, and in two exposures in the R=7000 mode. The use of transmissive coated optics, VPH gratings and optimized mirror coatings ensures a throughput (including telescope atmosphere and detector) >30% over a wide spectral range. The concentric image-slicer design ensures an excellent and uniform image quality across the full field. To maximize scientific return, the whole instrument is configured for remote observing, pipeline data reduction, and the accumulation of calibration image libraries.

  5. The Wide-Field Imaging Interferometry Testbed: Progress and Plans

    NASA Technical Reports Server (NTRS)

    Rinehart, S. A.; Leisawitz, D.; Leviton, D.; Martino, A.; Maynard, W.; Mundy, L. G.; Zhang, X.

    2004-01-01

    We describe the technique of wide field mosaic imaging for optical/IR interferometers and present early experimental results from a laboratory instrument designed to validate, experiment with, and refine the technique. A conventional single-detector stellar interferometer operating with narrow bandwidth at center wavelength lambda is limited in its field of view to the primary beam of the individual telescope apertures, or approx. lambda/D(sub tel) radians, where is the telescope diameter. Such a field is too small for many applications; often one wishes to image extended sources. We are developing and testing a technique analogous to the mosaic method employed in millimeter and radio astronomy, but applicable to optical/IR Michelson interferometers, in which beam combination is done in the pupil plane. An N(sub pix) x N(sub pix) detector array placed in the image plane of the interferometer is used to record simultaneously the fringe patterns from many contiguous telescope fields, effectively multiplying the field size by N(sub pix)/2, where the factor 2 allows for Nyquist sampling. This mosaic imaging technique will be especially valuable for far IR and submillimeter interferometric space observatories such as the Space Infrared Interferometric Telescope (SPIRIT) and the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). SPIRIT and SPECS will be designed to provide sensitive, high angular resolution observations of fields several arcminutes in diameter, and views of the universe complementary to those provided by HST, NGST, and ALMA.

  6. Science with a wide-field UV transient explorer

    SciTech Connect

    Sagiv, I.; Gal-Yam, A.; Ofek, E. O.; Waxman, E.; Trakhtenbrot, B.; Topaz, J.; Aharonson, O.; Kulkarni, S. R.; Phinney, E. S.; Nakar, E.; Maoz, D.; Beichman, C.; Murthy, J.; Worden, S. P.

    2014-04-01

    The time-variable electromagnetic sky has been well-explored at a wide range of wavelengths. In contrast, the ultra-violet (UV) variable sky is relatively poorly explored, even though it offers exciting scientific prospects. Here, we review the potential scientific impact of a wide-field UV survey on the study of explosive and other transient events, as well as known classes of variable objects, such as active galactic nuclei and variable stars. We quantify our predictions using a fiducial set of observational parameters which are similar to those envisaged for the proposed ULTRASAT mission. We show that such a mission would be able to revolutionize our knowledge about massive star explosions by measuring the early UV emission from hundreds of events, revealing key physical parameters of the exploding progenitor stars. Such a mission would also detect the UV emission from many tens of tidal-disruption events of stars by supermassive black holes at galactic nuclei and enable a measurement of the rate of such events. The overlap of such a wide-field UV mission with existing and planned gravitational-wave and high-energy neutrino telescopes makes it especially timely.

  7. WIDE-FIELD WIDE-BAND INTERFEROMETRIC IMAGING: THE WB A-PROJECTION AND HYBRID ALGORITHMS

    SciTech Connect

    Bhatnagar, S.; Rau, U.; Golap, K. E-mail: rurvashi@nrao.edu

    2013-06-20

    Variations of the antenna primary beam (PB) pattern as a function of time, frequency, and polarization form one of the dominant direction-dependent effects at most radio frequency bands. These gains may also vary from antenna to antenna. The A-Projection algorithm, published earlier, accounts for the effects of the narrow-band antenna PB in full polarization. In this paper, we present the wide-band A-Projection algorithm (WB A-Projection) to include the effects of wide bandwidth in the A-term itself and show that the resulting algorithm simultaneously corrects for the time, frequency, and polarization dependence of the PB. We discuss the combination of the WB A-Projection and the multi-term multi-frequency synthesis (MT-MFS) algorithm for simultaneous mapping of the sky brightness distribution and the spectral index distribution across a wide field of view. We also discuss the use of the narrow-band A-Projection algorithm in hybrid imaging schemes that account for the frequency dependence of the PB in the image domain.

  8. Wide-field wide-band Interferometric Imaging: The WB A-Projection and Hybrid Algorithms

    NASA Astrophysics Data System (ADS)

    Bhatnagar, S.; Rau, U.; Golap, K.

    2013-06-01

    Variations of the antenna primary beam (PB) pattern as a function of time, frequency, and polarization form one of the dominant direction-dependent effects at most radio frequency bands. These gains may also vary from antenna to antenna. The A-Projection algorithm, published earlier, accounts for the effects of the narrow-band antenna PB in full polarization. In this paper, we present the wide-band A-Projection algorithm (WB A-Projection) to include the effects of wide bandwidth in the A-term itself and show that the resulting algorithm simultaneously corrects for the time, frequency, and polarization dependence of the PB. We discuss the combination of the WB A-Projection and the multi-term multi-frequency synthesis (MT-MFS) algorithm for simultaneous mapping of the sky brightness distribution and the spectral index distribution across a wide field of view. We also discuss the use of the narrow-band A-Projection algorithm in hybrid imaging schemes that account for the frequency dependence of the PB in the image domain.

  9. Wide field-of-view microscopy with Talbot pattern illumination

    NASA Astrophysics Data System (ADS)

    Wu, Jigang; Liu, Guangshuo

    2012-12-01

    Wide field-of-view (FOV) microscopy is useful for high-throughput applications because of the capability to obtain large amount of information from a single image. One way to implement a wide FOV microscope is to scan the sample with a two-dimensional focus grid. The transmission or reflection of the focal spots can then be used to reconstruct the sample image. This scheme is effectively a parallel scanning optical microscope (SOM), where the FOV depends on the area of the focus grid and the imaging resolution depends on the spot size of the foci. We use the Talbot image of a twodimensional aperture grid as the focus grid and developed a wide FOV microscope. Preliminary experimental results show the capability of our microscope to acquire wide FOV images of US air force target and MCF-7 cancer cell samples. Fluorescence images of fluorescence beads are also acquired. Because the diffraction of incident beam by the aperture grid contains complicated angular frequencies, the focal spots in Talbot pattern cannot be approximated as Gaussian beams as in conventional SOM. We characterized the focal spots in Talbot pattern and studied the evolution of the full width at half maximum (FWHM). We also simulated the SOM imaging under Talbot pattern illumination using the razor blade as the sample objects.

  10. Superposition of an AC field improves the discrimination between peptides in nanopore analysis.

    PubMed

    Jakova, Elisabet; Lee, Jeremy S

    2015-07-21

    In standard nanopore analysis a constant DC voltage is used to electrophoretically drive small molecules and peptides towards a pore. Superposition of an AC voltage at particular frequencies causes molecules to oscillate as they approach the pore which can alter the event parameters, the blockade current (I) and blockade time (T). Four peptides with similar structures were studied. Alpha-helical peptides A10 (FmocDDA10KK), A14, A18 and retro-inverso A10. It was shown that the ratio of translocations to bumping events could be manipulated by a combination of AC voltages and frequencies. In particular, A10 could be studied without interference from retro-inverso A10. Similarly, a large, intrinsically disordered protein of 140 amino acids, α-synuclein, which translocates the pore readily in a DC field could be prevented from doing so by application of an AC field of 200 mV at 100 MHz. PMID:25699656

  11. Study of DC and AC electric field effect on Pisum sativum seeds growth

    NASA Astrophysics Data System (ADS)

    Mahmood, Bahar; Jaleh, Sojoodi; Yasaman, Yasaie

    2014-07-01

    In this research the effect of electric field on two groups of wet and dry Pisum sativum seeds growth was studied. To generate the required electric field a parallel-plate capacitor with round copper plates of 30 cm diameter was used. The experiments were performed once in fixed exposure duration of 8 min in variable DC electric field of 0.25-1.5 kV/m. The other experiments were performed in variable fields of 50-125 kV/m in fixed exposure duration of 8 min, in two groups of AC and DC electric fields. The experiments were repeated three times. In each experiment 10 seeds were used and there was a sham exposed group for comparison, too. After application of electric field, the seeds were kept for six days in the same growth chamber with the temperature of 25 ± 1 °C and 12 h light/12 h darkness. On the 6th day length of stems and height of roots were measured. After doing statistical analysis, in low intensities of DC electric field, the highest significant increase of mean growth (The average of stem length and the height of roots) was seen in 1.5 kV/m in wet seeds. In high intensities of DC and AC electric fields, the highest significant increase of mean growth was seen in AC electric field of 100 kV/m in wet seeds.

  12. OAOWFC: Okayama Astrophysical Observatory NIR Wide-Field Camera

    NASA Astrophysics Data System (ADS)

    Yoshida, M.; Yanagisawa, K.; Shimizu, Y.; Okita, K.; Nagayama, S.; Toda, H.; Ohta, K.; Kawai, N.

    2008-05-01

    In order to detect and trace the early phase of near-infrared (NIR) afterglows of Gamma Ray Bursts (GRBs) quickly, we are now developing the Okayama Astrophysical Observatory Wide-Field Camera, OAOWFC. The aperture size of OAOWFC is 91 cm. The focal plane is covered by a 2K×2K HAWAII2-RG detector with a pixel size of 18.5 μm×18.5 μm, resulting 0.95×0.95 deg2 field of view with an image scale of 1.6 arcsec/pixel. OAOWFC is designed to be a fully robotic instrument. This camera forms a part of Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME), a multi telescope system dedicated to optical-NIR follow-up observations of GRB afterglows. Very wide field of view of OAOWFC enables us to catch GRB afterglows under less accurate localization sometimes given by the first alert. OAOWFC has an ability to detect bright GRB afterglow located at z = 10 easily, and it might be detectable at z = 18 if the conditions are met.

  13. OAOWFC: Okayama Astrophysical Observatory NIR Wide-Field Camera

    SciTech Connect

    Yoshida, M.; Yanagisawa, K.; Shimizu, Y.; Okita, K.; Nagayama, S.; Toda, H.; Ohta, K.; Kawai, N.

    2008-05-22

    In order to detect and trace the early phase of near-infrared (NIR) afterglows of Gamma Ray Bursts (GRBs) quickly, we are now developing the Okayama Astrophysical Observatory Wide-Field Camera, OAOWFC. The aperture size of OAOWFC is 91 cm. The focal plane is covered by a 2Kx2K HAWAII2-RG detector with a pixel size of 18.5 {mu}mx18.5 {mu}m, resulting 0.95x0.95 deg{sup 2} field of view with an image scale of 1.6 arcsec/pixel. OAOWFC is designed to be a fully robotic instrument. This camera forms a part of Multicolor Imaging Telescopes for Survey and Monstrous Explosions (MITSuME), a multi telescope system dedicated to optical-NIR follow-up observations of GRB afterglows. Very wide field of view of OAOWFC enables us to catch GRB afterglows under less accurate localization sometimes given by the first alert. OAOWFC has an ability to detect bright GRB afterglow located at z = 10 easily, and it might be detectable at z = 18 if the conditions are met.

  14. Metrology systems of Hobby-Eberly Telescope wide field upgrade

    NASA Astrophysics Data System (ADS)

    Lee, Hanshin; Hill, Gary J.; Cornell, Mark E.; Vattiat, Brian L.; Perry, Dave M.; Rafferty, Tom H.; Taylor, Trey; Hart, Michael; Rafal, Marc D.; Savage, Richard D.

    2012-09-01

    The Hobby-Eberly Telescope (HET) Wide-Field Upgrade (WFU) will be equipped with new closed-loop metrology systems to actively control the optical alignment of the new four-mirror Wide-Field Corrector (WFC) as it tracks sidereal motion with respect to the fixed primary mirror. These systems include a tip/tilt camera (TTCam), distance measuring interferometers (DMI), guide probes (GP), and wavefront sensors (WFS). While the TTCam and DMIs are to monitor the mechanical alignment of the WFC, the WFSs and GPs will produce direct measurement of the optical alignment of the WFC with respect to the HET primary mirror. Together, these systems provide fully redundant alignment and pointing information for the telescope, thereby keeping the WFC in focus and suppressing alignment driven field aberrations. In addition to these closed-loop metrology systems, we will have a pupil viewing camera (PVCam) and a calibration wavefront sensor (CWFS). The PVCam will be used for occasional reflectance measurement of the HET primary mirror segments in the standard R,G,B colors. The CWFS will provide the reference wavefront signal against which the other two WFS are calibrated. We describe the current snapshot of these systems and discuss lab/on-sky performance test results of the systems.

  15. Facility calibration unit of Hobby Eberly Telescope wide field upgrade

    NASA Astrophysics Data System (ADS)

    Lee, Hanshin; Hill, Gary J.; Vattiat, Brian L.; Smith, Michael P.; Haeuser, Marco

    2012-09-01

    The Hobby-Eberly Telescope (HET) Wide-Field Upgrade (WFU) will be equipped with new Facility Calibration Unit (FCU). The FCU is in support of VIRUS and the facility instruments and consists of the head and source box. The FCU head, connected to the source box through two liquid light guides, is attached to the bottom of the WFU Wide-Field Corrector (WFC) and can be deployed into the beam to inject calibration light through the WFC whenever calibration is needed. A set of Fresnel lenses is used in the FCU head to mimic the caustics of M1 as much as possible to re-produce the telescope’s focal plane illumination pattern. Various imaging/non-imaging optical components (e.g. Compound Parabolic Concentrators, cone reflectors, condenser lenses) are used for efficient coupling between different types of calibration lamps and light guides, covering wavelengths from 350nm to 1800nm. In addition, we developed an efficient and tunable Light-Emitting Diode (LED) based source and coupler for UV and Visible spectral flat field calibration. This paper presents the designs, prototypes, and as-built components / subsystems of the FCU.

  16. The Spitzer Deep, Wide-Field Survey (SDWFS)

    NASA Astrophysics Data System (ADS)

    Ashby, Matthew; Stern, D.; Brodwin, M.; Griffith, R.; Eisenhardt, P.; Kozlowski, S.; Kochanek, C. S.; Bock, J.; Borys, C.; Brand, K.; Brown, M. J. I.; Cool, R.; Cooray, A.; Croft, S.; Dey, A.; Eisenstein, D.; Gonzalez, A.; Gorjian, V.; Grogin, N.; Ivison, R.; Jacob, J.; Jannuzi, B.; Mainzer, A.; Moustakas, L.; Rottgering, H.; Seymour, N.; Smith, H.; Stanford, A.; Stauffer, J. R.; Sullivan, I.; van Breugel, W.; Wright, E. L.; Willner, S. P.

    2009-05-01

    The Spitzer Deep, Wide-Field Survey (SDWFS) is four-epoch infrared survey of ten square degrees in the Bootes field of the NOAO Deep Wide-Field Survey using the IRAC instrument on the Spitzer Space Telescope. The four epochs, which span the interval from 2003 to 2008, make it possible to identify nearby, high-proper-motion targets, as well as infrared-variable objects. SDWFS is a Spitzer Cycle 4 Legacy program (PID 40839). The SDWFS catalogs are publicly available, and contain roughly 7e5, 5e5, 1e5, and 1e5 distinct sources brighter than the 5-sigma survey limits of 19.8, 18.8, 16.5, and 15.8 Vega magnitudes at 3.6, 4.5, 5.8, and 8.0 microns, respectively. In this contribution we describe the SDWFS survey and some initial findings. This work was supported by NASA grant number 1314516, administered by JPL.

  17. Wide-Field Plate Database: Included Ukrainian Plate Catalogues

    NASA Astrophysics Data System (ADS)

    Tsvetkova, Katya; Sergeeva, Tetyana

    2007-08-01

    We present the basic information for the archives of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine, included into the Wide-Field Plate Database last two years with total number of plates - 11260. The plates were obtained with the 0.40m Double Wide-angle Astrograph (DWA); 10cm, 11cm and 15cm Three Cameras Astrograph (TCA) and 12 cm Double Short focus Astrograph (DSA) in the period 1949-1998 in the frames of the following observing programmes: Photographic Survey of the Northern Sky; Investigation of the kinematics and the structure in the main meridian section of the Galaxy; selection of reference stars, minor planets observations, comet investigations.

  18. Non-mydriatic, wide field, fundus video camera

    NASA Astrophysics Data System (ADS)

    Hoeher, Bernhard; Voigtmann, Peter; Michelson, Georg; Schmauss, Bernhard

    2014-02-01

    We describe a method we call "stripe field imaging" that is capable of capturing wide field color fundus videos and images of the human eye at pupil sizes of 2mm. This means that it can be used with a non-dilated pupil even with bright ambient light. We realized a mobile demonstrator to prove the method and we could acquire color fundus videos of subjects successfully. We designed the demonstrator as a low-cost device consisting of mass market components to show that there is no major additional technical outlay to realize the improvements we propose. The technical core idea of our method is breaking the rotational symmetry in the optical design that is given in many conventional fundus cameras. By this measure we could extend the possible field of view (FOV) at a pupil size of 2mm from a circular field with 20° in diameter to a square field with 68° by 18° in size. We acquired a fundus video while the subject was slightly touching and releasing the lid. The resulting video showed changes at vessels in the region of the papilla and a change of the paleness of the papilla.

  19. The Wide-Field Imaging Interferometry Testbed: Recent Results

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen

    2006-01-01

    We present recent results from the Wide-Field Imaging Interferometry Testbed (WIIT). The data acquired with the WIIT is "double Fourier" data, including both spatial and spectral information within each data cube. We have been working with this data, and starting to develop algorithms, implementations, and techniques for reducing this data. Such algorithms and tools are of great importance for a number of proposed future missions, including the Space Infrared Interferometric Telescope (SPIRIT), the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS), and the Terrestrial Planet Finder Interferometer (TPF-I)/Darwin. Recent results are discussed and future study directions are described.

  20. 'Virtual triple Schmidt' - Wide field two-stage optics

    NASA Technical Reports Server (NTRS)

    Manhart, Paul K.

    1989-01-01

    The design concept of an unobscured-wide-field two-stage optical system based on a virtual triple Schmidt (VTS) configuration is presented. It is pointed out that the single large aperture and field-partitioning capability of two-stage systems can lower material and fabrication costs, making the VTS optics suitable for ground-based and space telescopes. The VTS design combines a Schmidt-camera first stage and a second stage comprising two back-to-back Schmidt systems as a 1:1 relay. Aspheric Schmidt correction is achieved at the relayed pupil location for all three systems. The effects of the separation between the error-producing surface and the aperture stop are discussed; the performance of the wavefront-correction system is analyzed; and extensive diagrams, drawings, and graphs of projected performance data are provided.

  1. Design and development of a wide field telescope

    NASA Astrophysics Data System (ADS)

    Moon, Il; Lee, Sangon; Lim, Juhee; Yang, Ho-Soon; Rhee, Hyug-Gyo; Song, Jae Bong; Lee, Yun Woo; Lee, Jong Ung; Jin, Ho

    2012-09-01

    A prototype of large wide field telescope is a Cassegrain telescope which covers 2° field of view with two hyperbolic mirrors, a 0.5 m primary mirror and a 0.2 m secondary mirror with multiple correction lenses. To fulfill the optical and mechanical performance requirements in design and development phase extensive finite element analyses using NX NASTRAN and optical analyses with CODE V and PCFRINGE have been conducted for the structure of optical system. Analyses include static deformation (gravity and thermal), frequency, dynamic response analysis, and optical performance evaluations for minimum optical deformation. Image motion is also calculated based on line of sight sensitivity equations integrated in finite element models. A parametric process was performed for the design optimization to produce highest fundamental frequency for a given weight, as well as to deal with the normal concerns about global performance.

  2. Wide-field Fizeau imaging telescope: experimental results.

    PubMed

    Kendrick, R L; Aubrun, Jean-Noel; Bell, Ray; Benson, Robert; Benson, Larry; Brace, David; Breakwell, John; Burriesci, Larry; Byler, Eric; Camp, John; Cross, Gene; Cuneo, Peter; Dean, Peter; Digumerthi, Ramji; Duncan, Alan; Farley, John; Green, Andy; Hamilton, Howard H; Herman, Bruce; Lauraitis, Kris; de Leon, Erich; Lorell, Kenneth; Martin, Rob; Matosian, Ken; Muench, Tom; Ni, Mel; Palmer, Alice; Roseman, Dennis; Russell, Sheldon; Schweiger, Paul; Sigler, Rob; Smith, John; Stone, Richard; Stubbs, David; Swietek, Gregg; Thatcher, John; Tischhauser, C; Wong, Harvey; Zarifis, Vassilis; Gleichman, Kurt; Paxman, Rick

    2006-06-20

    A nine-aperture, wide-field Fizeau imaging telescope has been built at the Lockheed-Martin Advanced Technology Center. The telescope consists of nine, 125 mm diameter collector telescopes coherently phased and combined to form a diffraction-limited image with a resolution that is consistent with the 610 mm diameter of the telescope. The phased field of view of the array is 1 murad. The measured rms wavefront error is 0.08 waves rms at 635 nm. The telescope is actively controlled to correct for tilt and phasing errors. The control sensing technique is the method known as phase diversity, which extracts wavefront information from a pair of focused and defocused images. The optical design of the telescope and typical performance results are described. PMID:16778931

  3. AC Electric Field-Induced Trapping of Microparticles in Pinched Microconfinements.

    PubMed

    Dey, Ranabir; Shaik, Vaseem Akram; Chakraborty, Debapriya; Ghosal, Sandip; Chakraborty, Suman

    2015-06-01

    The trapping of charged microparticles under confinement in a converging-diverging microchannel, under a symmetric AC field of tunable frequency, is studied. We show that at low frequencies, the trapping characteristics stem from the competing effects of positive dielectrophoresis and the linear electrokinetic phenomena of electroosmosis and electrophoresis. It is found, somewhat unexpectedly, that electroosmosis and electrophoresis significantly affect the concentration profile of the trapped analyte, even for a symmetric AC field. However, at intermediate frequencies, the microparticle trapping mechanism is predominantly a consequence of positive dielectrophoresis. We substantiate our experimental results for the microparticle concentration distribution, along the converging-diverging microchannel, with a detailed theoretical analysis that takes into account all of the relevant frequency-dependent electrokinetic phenomena. This study should be useful in understanding the response of biological components such as cells to applied AC fields. Moreover, it will have potential applications in the design of efficient point-of-care diagnostic devices for detecting biomarkers and also possibly in some recent strategies in cancer therapy using AC fields. PMID:25954982

  4. Wide-field Ca2+ imaging reveals visually evoked activity in the retrosplenial area

    PubMed Central

    Murakami, Tomonari; Yoshida, Takashi; Matsui, Teppei; Ohki, Kenichi

    2015-01-01

    Due to recent advances of genetic manipulation, mouse brain has become a useful model for studying brain function, which demands whole brain functional mapping techniques in the mouse brain. In the present study, to finely map visual responsive areas in the mouse brain, we combined high-resolution wide-field optical imaging with transgenic mice containing the genetically encoded Ca2+ indicator, GCaMP3. With the high signal amplitude of GCaMP3 expressing in excitatory neurons, this system allowed neural activity to be observed with relatively fine spatial resolution and cell-type specificity. To evaluate this system, we examined whether non-visual areas exhibited a visual response over the entire surface of the mouse hemisphere. We found that two association areas, the retrosplenial area (RS) and secondary motor/anterior cingulate area (M2/AC), were significantly responsive to drifting gratings. Examination using gratings with distinct spatiotemporal frequency parameters revealed that the RS strongly responded to high-spatial and low-temporal frequency gratings. The M2/AC exhibited a response property similar to that of the RS, though it was not statistically significant. Finally, we performed cellular imaging using two-photon microscopy to examine orientation and direction selectivity of individual neurons, and found that a minority of neurons in the RS clearly showed visual responses sharply selective for orientation and direction. These results suggest that neurons in RS encode visual information of fine spatial details in images. Thus, the present study shows the usefulness of the functional mapping method using a combination of wide-field and two-photon Ca2+ imaging, which allows for whole brain mapping with high spatiotemporal resolution and cell-type specificity. PMID:26106292

  5. A wide bandwidth electrostatic field sensor for lightning research

    NASA Technical Reports Server (NTRS)

    Zaepfel, Klaus P.

    1989-01-01

    Data obtained from UHF radar observation of direct-lightning strikes to the NASA F-106B aircraft have indicated that most of the 690 strikes acquired during direct-strike lightning tests were triggered by the aircraft. As an aid in understanding the triggered lightning process, a wide bandwidth electric field measuring system was designed for the F-106B by implementing a clamped-detection signal processing concept originated at the Air Force Cambridge Research Lab in 1953. The detection scheme combines the signals from complementary stator pairs clamped to zero bolts at the exact moment when each stator pair is maximally shielded by the rotor, a process that restores the dc level lost by the charge amplifier. The system was implemented with four shutter-type field mills located at strategic points on the aircraft. The bandwidth of the system was determined in the laboratory to be from dc to over 100 Hz, whereas past designs had upper limits of 10 to 100 Hz. To obtain the undisturbed electric field vector and total aircraft charge, the airborne field mill system is calibrated by using techniques involving results from ground and flight calibrations of the F-106B, laboratory tests of a metallized model, and a finite difference time-domain electromagnetic computer code.

  6. A wide bandwidth electrostatic field sensor for lightning research

    NASA Technical Reports Server (NTRS)

    Zaepfel, K. P.

    1986-01-01

    Data obtained from UHF Radar observation of direct-lightning strikes to the NASA F-106B airplane have indicated that most of the 690 strikes acquired during direct-strike lightning tests were triggered by the aircraft. As an aid in understanding the triggered lightning process, a wide bandwidth electric field measuring system was designed for the F-106B by implementing a clamped-detection signal processing concept originated at the Air Force Cambridge Research Lab in 1953. The detection scheme combines the signals from complementary stator pairs clamped to zero volts at the exact moment when each stator pair is maximally shielded by the rotor, a process that restores the dc level lost by the charge amplifier. The new system was implemented with four shutter-type field mills located at strategic points on the airplane. The bandwidth of the new system was determined in the laboratory to be from dc to over 100 Hz, whereas past designs had upper limits of 10 Hz to 100 Hz. To obtain the undisturbed electric field vector and total aircraft charge, the airborne field mill system is calibrated by using techniques involving results from ground and flight calibrations of the F-106B, laboratory tests of a metallized model, and a finite-difference time-domain electromagnetic computer code.

  7. HST Wide Field and Planetary Camera II Status Update

    NASA Astrophysics Data System (ADS)

    Heyer, I.; Biretta, J.; Baggett, S.; Gonzaga, S.; Koekemoer, A.; Lubin, L.; Mack, J.; McMaster, M.; Platais, V.; Schultz, A.

    2001-12-01

    We review the status of the Wide Field and Planetary Camera II (WFPC2) onboard the Hubble Space Telescope, as well as recent enhancements to calibration and user support. The photometric, flat field, and PSF stabilities continue to be excellent. Charge Transfer Efficiency (CTE) in the CCDs remains a concern; we discuss the latest results from on-going monitor programs, as well as the latest correction procedures. Work is underway to update the entire set of flat fields; we discuss the new flats, as well as the low-noise flat fields corrections released last summer. The "On-the-Fly-Reprocessing" system continues to perform well, though we mention issues affecting a few images. The WFPC2 Exposure Time Calculator has been updated, and is available on our website. A new WFPC2 Pointings Search Interface tool for the HST Archive has been released. The WFPC2 Instrument Handbook has been updated for Cycle 11, and a new edition of the HST Data Handbook is currently in progress. The next Servicing Mission (SM3b) is slated for February 2002; and we summarize the post-SM tests which are planned for WFPC2. These and other issues will be discussed.

  8. Mitigating fluorescence spectral overlap in wide-field endoscopic imaging

    PubMed Central

    Hou, Vivian; Nelson, Leonard Y.; Seibel, Eric J.

    2013-01-01

    Abstract. The number of molecular species suitable for multispectral fluorescence imaging is limited due to the overlap of the emission spectra of indicator fluorophores, e.g., dyes and nanoparticles. To remove fluorophore emission cross-talk in wide-field multispectral fluorescence molecular imaging, we evaluate three different solutions: (1) image stitching, (2) concurrent imaging with cross-talk ratio subtraction algorithm, and (3) frame-sequential imaging. A phantom with fluorophore emission cross-talk is fabricated, and a 1.2-mm ultrathin scanning fiber endoscope (SFE) is used to test and compare these approaches. Results show that fluorophore emission cross-talk could be successfully avoided or significantly reduced. Near term, the concurrent imaging method of wide-field multispectral fluorescence SFE is viable for early stage cancer detection and localization in vivo. Furthermore, a means to enhance exogenous fluorescence target-to-background ratio by the reduction of tissue autofluorescence background is demonstrated. PMID:23966226

  9. The Wide-Field Imaging Interferometry Testbed: Progress and Plans

    NASA Astrophysics Data System (ADS)

    Leisawitz, D.; Leviton, D.; Martino, A.; Maynard, W.; Mundy, L. G.; Rinehart, S. A.; Zhang, X.; WIIT Science and Technical Advisory Group Team

    2001-12-01

    We describe the technique of wide field mosaic imaging for optical/IR interferometers and present early experimental results from a laboratory instrument designed to validate, experiment with, and refine the technique. A conventional single-detector stellar interferometer operating with narrow bandwidth at center wavelength λ is limited in its field of view to the primary beam of the individual telescope apertures, or ~ λ / Dtel radians, where Dtel is the telescope diameter. Such a field is too small for many applications; often one wishes to image extended sources. We are developing and testing a technique analogous to the mosaicing method employed in millimeter and radio astronomy, but applicable to optical/IR Michelson interferometers, in which beam combination is done in the pupil plane. An Npix x Npix array detector placed in the image plane of the interferometer is used to record simultaneously the fringe patterns from many contiguous telescope fields, effectively multiplying the field size by Npix/2, where the factor 2 allows for Nyquist sampling. This technology will be especially valuable for far IR and submillimeter interferometric space observatories such as the Space Infrared Interferometric Telescope (SPIRIT) and the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). SPIRIT and SPECS will be designed to provide sensitive, high angular resolution observations of fields several arcminutes in diameter, and views of the universe complementary to those provided by HST, NGST, and ALMA. Funding for WIIT is provided by NASA Headquarters through the ROSS/SARA Program and by the Goddard Space Flight Center through its IR&D Program.

  10. Wide-field Infrared Polarimetry of the ρ Ophiuchi Cloud Core

    NASA Astrophysics Data System (ADS)

    Kwon, Jungmi; Tamura, Motohide; Hough, James H.; Nakajima, Yasushi; Nishiyama, Shogo; Kusakabe, Nobuhiko; Nagata, Tetsuya; Kandori, Ryo

    2015-09-01

    We conducted wide and deep simultaneous JHKs-band imaging polarimetry of the ρ Ophiuchi cloud complex. Aperture polarimetry in the JHKs band was conducted for 2136 sources in all three bands, of which 322 sources have significant polarizations in all the JHKs bands and have been used for a discussion of the core magnetic fields. There is a positive correlation between degrees of polarization and H - Ks color up to H - Ks ≈ 3.5. The magnetic field structures in the core region are revealed up to at least AV ≈ 47 mag and are unambiguously defined in each sub-region (core) of Oph-A, Oph-B, Oph-C, Oph-E, Oph-F, and Oph-AC. Their directions, degrees of polarization, and polarization efficiencies differ but their changes are gradual; thus, the magnetic fields appear to be connected from core to core, rather than as a simple overlap of the different cloud core components. Comparing our results with the large-scale field structures obtained from previous optical polarimetric studies, we suggest that the magnetic field structures in the core were distorted by the cluster formation in this region, which may have been induced by shock compression due to wind/radiation from the Scorpius-Centaurus association.

  11. Genome-wide bioinformatics analysis of steroid metabolism-associated genes in Nocardioides simplex VKM Ac-2033D.

    PubMed

    Shtratnikova, Victoria Y; Schelkunov, Mikhail I; Fokina, Victoria V; Pekov, Yury A; Ivashina, Tanya; Donova, Marina V

    2016-08-01

    Actinobacteria comprise diverse groups of bacteria capable of full degradation, or modification of different steroid compounds. Steroid catabolism has been characterized best for the representatives of suborder Corynebacterineae, such as Mycobacteria, Rhodococcus and Gordonia, with high content of mycolic acids in the cell envelope, while it is poorly understood for other steroid-transforming actinobacteria, such as representatives of Nocardioides genus belonging to suborder Propionibacterineae. Nocardioides simplex VKM Ac-2033D is an important biotechnological strain which is known for its ability to introduce ∆(1)-double bond in various 1(2)-saturated 3-ketosteroids, and perform convertion of 3β-hydroxy-5-ene steroids to 3-oxo-4-ene steroids, hydrolysis of acetylated steroids, reduction of carbonyl groups at C-17 and C-20 of androstanes and pregnanes, respectively. The strain is also capable of utilizing cholesterol and phytosterol as carbon and energy sources. In this study, a comprehensive bioinformatics genome-wide screening was carried out to predict genes related to steroid metabolism in this organism, their clustering and possible regulation. The predicted operon structure and number of candidate gene copies paralogs have been estimated. Binding sites of steroid catabolism regulators KstR and KstR2 specified for N. simplex VKM Ac-2033D have been calculated de novo. Most of the candidate genes grouped within three main clusters, one of the predicted clusters having no analogs in other actinobacteria studied so far. The results offer a base for further functional studies, expand the understanding of steroid catabolism by actinobacteria, and will contribute to modifying of metabolic pathways in order to generate effective biocatalysts capable of producing valuable bioactive steroids. PMID:26832142

  12. AC current distribution and losses in multifilamentary superconductors exposed to longitudinal magnetic field

    SciTech Connect

    Le Naour, S.; Lacaze, A.; Laumond, Y.; Estop, P.; Verhaege, T.

    1996-07-01

    The current distribution and also AC losses, in a multifilamentary superconductor carrying a transport current, are influenced by the self and the external magnetic field. By using the Maxwell equations, a model has been developed in order to calculate the temporal evolution of current distribution in a single wire exposed or not to external magnetic field. This model is based on the actual relationship of electrical field E with current density J and takes into account the twist pitch of the wire. AC losses are calculated by adding all local losses through the cross section. This paper presents calculations of the influence of the cable twist coupled with the longitudinal magnetic field, and also gives some ideas how to decrease losses.

  13. Stability of the ACS CCD: geometry, flat fielding, photometry

    NASA Astrophysics Data System (ADS)

    De Marchi, Guido

    2002-07-01

    A moderately crowded stellar field, located 6' West of the centre of the cluster 47 Tuc, is observed repeatedly {every three weeks with the WFC, every other month with the HRC} in various filters, spending 1 orbit per epoch. Different filters will be used every time, so that over the course of the year all filters will have been employed at least twice. The most common filters will be checked more frequently. The same field has been observed in the course of the SMOV phase and the positions and magnitudes of the most prominent stars have been accurately measured. Although the field is neither a proper astrometric nor a proper photometric standard one, the positions and magnitudes of the objects in it can be used to monitor any local and large scale variations in the platescale and sensitivity of the detectors. It should be noted that for the filters which have already been used during the SMOV phase it will be sufficient to take one single image, without CR-SPLIT, since the exposure time is always short {20-30 sec} and there will be so many stars that the few of them which are affected by cosmic rays can be discarded as outliers in the photometry. For narrow and medium band filters not exercised on this target in the SMOV phase, however, a baseline will have to be set. This expenditure of time will apply to the current cycle only. At variance with the approach used in SMOV, there is no need for large telescope slews to place the same objects on opposite sides of the detectors, thence allowing the programme to remain compact and efficient. All exposure level parameters are set to their default values, except for the amplifier gain of the WFC exposures in the F606W band, which will be collected with the gain value of 2 for the WFC for compatibility with the SMOV observations. The exposure time is typically 30 seconds for the WFC, 60 sec for the HRC. No attempt will be made to attain a predefined or the same orientation on the sky amongst different epochs. Typically

  14. Wide-field-of-view (WFOV) night vision goggle

    NASA Astrophysics Data System (ADS)

    Isbell, Wayne; Estrera, Joseph P.

    2003-09-01

    The United States' armed forces continue to be presented with increased challenges in adverse operational environments with increasing risk and complexity - especially at night. To ensure continued operational success and battlefield superiority during darkness, our armed forces must be equipped with night vision (NV) systems providing increased situational awareness. Doing so will significantly enhance threat detection and engagement, as well as survivability, thus ensuring greater mission success. Northrop Grumman Electro-Optical Systems (EOS) continues to develop its Wide Field of View (WFOV) image intensification (I2) night vision system for ground forces. This system will provide a significant increase in visual coverage enabling US forces to continue "to own the night". Until now, NV systems have typically been limited to a 40-degree field of view (FOV), vertically and horizontally. This limited FOV reduces off-axis detection, restricts an individual soldier's recognition and engagement capabilities and hinders added peripheral vision. To counter this operational deficiency, EOS proposes the Wide Field of View (WFOV) night vision binocular. The WFOV system will have a 70-degree horizontal FOV, with a 55-degree vertical FOV. The increased FOV will result in increased situational awareness of soldiers' surrounding environment (including terrain, hazards, threat, etc) during normal night operations. It will also allow for rapid and safer movement, especially in MOUT operations. Additionally, the increased visual coverage of large areas will enable soldiers to detect and engage targets faster and with greater reliability. The WFOV binocular will significantly enhance survivability, threat detection and engagement, and hence, greater mission success rate.

  15. Wide-Field-of-View, High-Resolution, Stereoscopic Imager

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F.; Sedwick, Raymond J.

    2010-01-01

    A device combines video feeds from multiple cameras to provide wide-field-of-view, high-resolution, stereoscopic video to the user. The prototype under development consists of two camera assemblies, one for each eye. One of these assemblies incorporates a mounting structure with multiple cameras attached at offset angles. The video signals from the cameras are fed to a central processing platform where each frame is color processed and mapped into a single contiguous wide-field-of-view image. Because the resolution of most display devices is typically smaller than the processed map, a cropped portion of the video feed is output to the display device. The positioning of the cropped window will likely be controlled through the use of a head tracking device, allowing the user to turn his or her head side-to-side or up and down to view different portions of the captured image. There are multiple options for the display of the stereoscopic image. The use of head mounted displays is one likely implementation. However, the use of 3D projection technologies is another potential technology under consideration, The technology can be adapted in a multitude of ways. The computing platform is scalable, such that the number, resolution, and sensitivity of the cameras can be leveraged to improve image resolution and field of view. Miniaturization efforts can be pursued to shrink the package down for better mobility. Power savings studies can be performed to enable unattended, remote sensing packages. Image compression and transmission technologies can be incorporated to enable an improved telepresence experience.

  16. DMD-based programmable wide field spectrograph for Earth observation

    NASA Astrophysics Data System (ADS)

    Zamkotsian, Frédéric; Lanzoni, Patrick; Liotard, Arnaud; Viard, Thierry; Costes, Vincent; Hébert, Philippe-Jean

    2015-03-01

    In Earth Observation, Universe Observation and Planet Exploration, scientific return could be optimized in future missions using MOEMS devices. In Earth Observation, we propose an innovative reconfigurable instrument, a programmable wide-field spectrograph where both the FOV and the spectrum could be tailored thanks to a 2D micromirror array (MMA). For a linear 1D field of view (FOV), the principle is to use a MMA to select the wavelengths by acting on intensity. This component is placed in the focal plane of a first grating. On the MMA surface, the spatial dimension is along one side of the device and for each spatial point, its spectrum is displayed along the perpendicular direction: each spatial and spectral feature of the 1D FOV is then fully adjustable dynamically and/or programmable. A second stage with an identical grating recomposes the beam after wavelengths selection, leading to an output tailored 1D image. A mock-up has been designed, fabricated and tested. The micromirror array is the largest DMD in 2048 x 1080 mirrors format, with a pitch of 13.68μm. A synthetic linear FOV is generated and typical images have been recorded o at the output focal plane of the instrument. By tailoring the DMD, we could modify successfully each pixel of the input image: for example, it is possible to remove bright objects or, for each spatial pixel, modify the spectral signature. The very promising results obtained on the mock-up of the programmable wide-field spectrograph reveal the efficiency of this new instrument concept for Earth Observation.

  17. A Genome-Wide Association Study Identifies Two Novel Promising Candidate Genes Affecting Escherichia coli F4ab/F4ac Susceptibility in Swine

    PubMed Central

    Lu, Xin; Niu, Xiao-Yan; Ding, Xiang-Dong; Liu, Jian-Feng; Zhang, Qin

    2012-01-01

    Enterotoxigenic Escherichia coli (ETEC) expressing F4 fimbria is the major pathogenic bacteria causing diarrhoea in neonatal and post-weaning piglets. Previous studies have revealed that the susceptibility to ETEC F4ab/F4ac is an autosomal Mendelian dominant trait and the loci controlling the F4ab/F4ac receptor are located on SSC13q41, between markers SW207 and S0283. To pinpoint these loci and further validate previous findings, we performed a genome-wide association study (GWAS) using a two generation family-based population, consisting of 301 piglets with phenotypes of susceptibility to ETEC F4ab/F4ac by the vitro adhesion test. The DNA of all piglets and their parents was genotyped using the Illumina PorcineSNP60 BeadChip, and 50,972 and 50,483 SNPs were available for F4ab and F4ac susceptibility, respectively, in the association analysis after quality control. In summary, 28 and 18 significant SNPs (p<0.05) were detected associated with F4ab and F4ac susceptibility respectively at genome-wide significance level. From these significant findings, two novel candidate genes, HEG1 and ITGB5, were firstly identified as the most promising genes underlying F4ab/F4ac susceptibility in swine according to their functions and positions. Our findings herein provide a novel evidence for unravelling genetic mechanism of diarrhoea risk in piglets. PMID:22457712

  18. Deepest Wide-Field Colour Image in the Southern Sky

    NASA Astrophysics Data System (ADS)

    2003-01-01

    LA SILLA CAMERA OBSERVES CHANDRA DEEP FIELD SOUTH ESO PR Photo 02a/03 ESO PR Photo 02a/03 [Preview - JPEG: 400 x 437 pix - 95k] [Normal - JPEG: 800 x 873 pix - 904k] [HiRes - JPEG: 4000 x 4366 pix - 23.1M] Caption : PR Photo 02a/03 shows a three-colour composite image of the Chandra Deep Field South (CDF-S) , obtained with the Wide Field Imager (WFI) camera on the 2.2-m MPG/ESO telescope at the ESO La Silla Observatory (Chile). It was produced by the combination of about 450 images with a total exposure time of nearly 50 hours. The field measures 36 x 34 arcmin 2 ; North is up and East is left. Technical information is available below. The combined efforts of three European teams of astronomers, targeting the same sky field in the southern constellation Fornax (The Oven) have enabled them to construct a very deep, true-colour image - opening an exceptionally clear view towards the distant universe . The image ( PR Photo 02a/03 ) covers an area somewhat larger than the full moon. It displays more than 100,000 galaxies, several thousand stars and hundreds of quasars. It is based on images with a total exposure time of nearly 50 hours, collected under good observing conditions with the Wide Field Imager (WFI) on the MPG/ESO 2.2m telescope at the ESO La Silla Observatory (Chile) - many of them extracted from the ESO Science Data Archive . The position of this southern sky field was chosen by Riccardo Giacconi (Nobel Laureate in Physics 2002) at a time when he was Director General of ESO, together with Piero Rosati (ESO). It was selected as a sky region towards which the NASA Chandra X-ray satellite observatory , launched in July 1999, would be pointed while carrying out a very long exposure (lasting a total of 1 million seconds, or 278 hours) in order to detect the faintest possible X-ray sources. The field is now known as the Chandra Deep Field South (CDF-S) . The new WFI photo of CDF-S does not reach quite as deep as the available images of the "Hubble Deep Fields

  19. Numerical and theoretical evaluations of AC losses for single and infinite numbers of superconductor strips with direct and alternating transport currents in external AC magnetic field

    NASA Astrophysics Data System (ADS)

    Kajikawa, K.; Funaki, K.; Shikimachi, K.; Hirano, N.; Nagaya, S.

    2010-11-01

    AC losses in a superconductor strip are numerically evaluated by means of a finite element method formulated with a current vector potential. The expressions of AC losses in an infinite slab that corresponds to a simple model of infinitely stacked strips are also derived theoretically. It is assumed that the voltage-current characteristics of the superconductors are represented by Bean’s critical state model. The typical operation pattern of a Superconducting Magnetic Energy Storage (SMES) coil with direct and alternating transport currents in an external AC magnetic field is taken into account as the electromagnetic environment for both the single strip and the infinite slab. By using the obtained results of AC losses, the influences of the transport currents on the total losses are discussed quantitatively.

  20. Calibration Status and Results for Wide Field Camera 3

    NASA Technical Reports Server (NTRS)

    Kimble, Randy A.

    2006-01-01

    Wide Field Camera 3 (WFC3) is a general-purpose imager in development for installation in HST Servicing Mission 4 (SM4). Covering the wavelength range of 200-1700 nm in two observing channels, WFC3 offers powerful new capabilities, particularly in the near-ultraviolet and near-infrared bands. During 2004, the instrument was integrated and underwent a substantial suite of end-to-end characterization and performance tests. In this paper, we present a brief overview of the design and scientific purpose of WFC3, summarize the results of its test program to date, and highlight some recent developments in detector technology that will further enhance the performance of WFC3 s IR channel.

  1. Wide-Field Astronomical Surveys in the Next Decade

    SciTech Connect

    Strauss, Michael A.; Tyson, J.Anthony; Anderson, Scott F.; Axelrod, T.S.; Becker, Andrew C.; Bickerton, Steven J.; Blanton, Michael R.; Burke, David L.; Condon, J.J.; Connolly, A.J.

    2009-03-01

    Wide-angle surveys have been an engine for new discoveries throughout the modern history of astronomy, and have been among the most highly cited and scientifically productive observing facilities in recent years. This trend is likely to continue over the next decade, as many of the most important questions in astrophysics are best tackled with massive surveys, often in synergy with each other and in tandem with the more traditional observatories. We argue that these surveys are most productive and have the greatest impact when the data from the surveys are made public in a timely manner. The rise of the 'survey astronomer' is a substantial change in the demographics of our field; one of the most important challenges of the next decade is to find ways to recognize the intellectual contributions of those who work on the infrastructure of surveys (hardware, software, survey planning and operations, and databases/data distribution), and to make career paths to allow them to thrive.

  2. Wide-Field Astronomical Surveys in the Next Decade

    SciTech Connect

    Strauss, Michael A.; Tyson, J.Anthony; Anderson, Scott F.; Axelrod, T.S.; Becker, Andrew C.; Bickerton, Steven J.; Blanton, Michael R.; Burke, David L.; Condon, J.J.; Connolly, A.J.; Cooray, Asantha R.; Covey, Kevin R.; Csabai, Istvan; Ferguson, Henry C.; Ivezic, Zeljko; Kantor, Jeffrey; Kent, Stephen M.; Knapp, G.R.; Myers, Steven T.; Neilsen, Eric H., Jr.; Nichol, Robert C.; /Portsmouth U., ICG /Harish-Chandra Res. Inst. /Caltech, IPAC /Potsdam, Max Planck Inst. /Harvard U. /Hawaii U. /UC, Berkeley, Astron. Dept. /Baltimore, Space Telescope Sci. /NOAO, Tucson /Carnegie Mellon U. /Chicago U., Astron. Astrophys. Ctr.

    2011-11-14

    Wide-angle surveys have been an engine for new discoveries throughout the modern history of astronomy, and have been among the most highly cited and scientifically productive observing facilities in recent years. This trend is likely to continue over the next decade, as many of the most important questions in astrophysics are best tackled with massive surveys, often in synergy with each other and in tandem with the more traditional observatories. We argue that these surveys are most productive and have the greatest impact when the data from the surveys are made public in a timely manner. The rise of the 'survey astronomer' is a substantial change in the demographics of our field; one of the most important challenges of the next decade is to find ways to recognize the intellectual contributions of those who work on the infrastructure of surveys (hardware, software, survey planning and operations, and databases/data distribution), and to make career paths to allow them to thrive.

  3. Wide Field X-Ray Telescope Mission Concept Study Results

    NASA Technical Reports Server (NTRS)

    Hopkins, R. C.; Thomas, H. D.; Fabisinski, L. L.; Baysinger, M.; Hornsby, L. S.; Maples, C. D.; Purlee, T. E.; Capizzo, P. D.; Percy, T. K.

    2014-01-01

    The Wide Field X-Ray Telescope (WFXT) is an astrophysics mission concept for detecting and studying extra-galactic x-ray sources, including active galactic nuclei and clusters of galaxies, in an effort to further understand cosmic evolution and structure. This Technical Memorandum details the results of a mission concept study completed by the Advanced Concepts Office at NASA Marshall Space Flight Center in 2012. The design team analyzed the mission and instrument requirements, and designed a spacecraft that enables the WFXT mission while using high heritage components. Design work included selecting components and sizing subsystems for power, avionics, guidance, navigation and control, propulsion, structures, command and data handling, communications, and thermal control.

  4. Prospects for a Wide Field CCD Camera Aboard NGST

    NASA Astrophysics Data System (ADS)

    Golimowski, D. A.; Ford, H. C.; Tsvetanov, Z. I.; Burrows, C. J.; Krist, J. E.; White, R. L.; Clampin, M.; Rafal, M.; Hartig, G.

    1998-05-01

    The importance of a Next Generation Space Telescope (NGST) for studying the infrared universe has often overshadowed NGST's potential benefit to optical astronomy. As currently envisioned, NGST could also provide views of the visible universe with resolution and sensitivity that are unmatched by any existing ground- or space-based observatory. We discuss the scientific advantages and technical feasibility of placing a wide-field CCD camera aboard NGST. Using simulated data, we compare the imaging performance of such a camera with that achieved or expected with the Keck Telescope and the HST Advanced Camera for Surveys. Finally, we discuss the technical challenges of temperature regulation and radiation shielding for a CCD camera in the NGST environment.

  5. Data Reduction Algorithm for Optical Wide Field Patrol (OWL)

    NASA Astrophysics Data System (ADS)

    Park, S.; Park, Y.; Yim, H.; Jo, J.; Moon, H.; Bae, Y.; Lim, Y.; Choi, J.; Choi, Y.; Park, J.; Son, J.

    2014-09-01

    OWL (Optical Wide-field Patrol) has a detector system which has the chopper which consists of 4 blades in front of the CCD camera to acquire efficiently the position and time information of moving objects such as artificial satellites. Using this system, it is possible to get more position data by splitting the streaks of the moving object into many pieces with fast rotating blades during tracking. At the same time, the time data of the rotating chopper can be acquired by the time tagger connected to the photo diode. In order to derive the orbits of the targets, we need a sequential data reduction procedure including the calculation of WCS (World Coordinate System) solution to transform the positions into equatorial coordinate systems, and the combination of the time data from the time tagger and the position data. We present such a data reduction procedure and the preliminary results after applying this procedure to the observation images.

  6. Wide-Field InfraRed Survey Telescope WFIRST

    NASA Technical Reports Server (NTRS)

    Green, J.; Schechter, P.; Baltay, C.; Bean, R.; Bennett, D.; Brown, R.; Conselice, C.; Donahue, M.; Fan, X.; Rauscher, B.; Rhodes, J.; Roellig, T.; Stern, D.; Gehrels, N.; Sambruna, R.; Traub, W.; Barry, R. K.; Content, D.; Goullioud, R.; Grady, K.; Kruk, J.; Melton, M.; Peddie, C.; Rioux, N.; Seiffert, M.

    2012-01-01

    In December 2010, NASA created a Science Definition Team (SDT) for WFIRST, the Wide Field Infra-Red Survey Telescope, recommended by the Astro 2010 Decadal Survey as the highest priority for a large space mission. The SDT was chartered to work with the WFIRST Project Office at GSFC and the Program Office at JPL to produce a Design Reference Mission (DRM) for WFIRST. Part of the original charge was to produce an interim design reference mission by mid-2011. That document was delivered to NASA and widely circulated within the astronomical community. In late 2011 the Astrophysics Division augmented its original charge, asking for two design reference missions. The first of these, DRM1, was to be a finalized version of the interim DRM, reducing overall mission costs where possible. The second of these, DRM2, was to identify and eliminate capabilities that overlapped with those of NASA's James Webb Space Telescope (henceforth JWST), ESA's Euclid mission, and the NSF's ground-based Large Synoptic Survey Telescope (henceforth LSST), and again to reduce overall mission cost, while staying faithful to NWNH. This report presents both DRM1 and DRM2.

  7. Astro-WISE Processing of Wide-field Images and Other Data

    NASA Astrophysics Data System (ADS)

    Buddelmeijer, H.; Williams, O. R.; McFarland, J. P.; Belikov, A.

    2012-09-01

    Astro-WISE (Vriend et al. 2012) is the Astronomical Wide-field Imaging System for Europe (Valentijn et al. 2007). It is a scientific information system which consists of hardware and software federated over about a dozen institutes throughout Europe. It has been developed to exploit the ever increasing avalanche of data produced by astronomical surveys and data intensive scientific experiments in general. The demo explains the architecture of the Astro-WISE information system and shows the use of Astro-WISE interfaces. Wide-field astronomical images are derived from the raw image to the final catalog according to the user's request. The demo is based on the standard Astro-WISE guided tour, which can be accessed from the Astro-WISE website. The typical Astro-WISE data processing chain is shown, which can be used for data handling for a variety of different instruments, currently 14, including OmegaCAM, MegaCam, WFI, WFC, ACS/HST, etc.

  8. PILOT: a wide-field telescope for the Antarctic plateau

    NASA Astrophysics Data System (ADS)

    Saunders, Will; Gillingham, Peter; McGrath, Andrew; Haynes, Roger; Brzeski, Jurek; Storey, John; Lawrence, Jon

    2008-07-01

    PILOT (the Pathfinder for an International Large Optical Telescope) is a proposed Australian/European optical/infrared telescope for Dome C on the Antarctic Plateau, with target first light in 2012. The telescope is 2.4m diameter, with overall focal ratio f/10, and a 1 degree field-of-view. It is mounted on a 30m tower to get above most of the turbulent surface layer, and has a tip-tilt secondary for fast guiding. In median seeing conditions, it delivers 0.3" FWHM wide-field image quality, from 0.7-2.5 microns. In the best quartile of conditions, it delivers diffraction-limited imaging down to 1 micron, or even less with lucky imaging. The major challenges have been (a) preventing frost-laden external air reaching the optics, (b) overcoming residual surface layer turbulence, (c) keeping mirror, telescope and dome seeing to acceptable levels in the presence of large temperature variations with height and time, (d) designing optics that do justice to the site conditions. The most novel feature of the design is active thermal and humidity control of the enclosure, to closely match the temperature of external air while preventing its ingress.

  9. Wide Field-of-View Fluorescence Imaging of Coral Reefs

    PubMed Central

    Treibitz, Tali; Neal, Benjamin P.; Kline, David I.; Beijbom, Oscar; Roberts, Paul L. D.; Mitchell, B. Greg; Kriegman, David

    2015-01-01

    Coral reefs globally are declining rapidly because of both local and global stressors. Improved monitoring tools are urgently needed to understand the changes that are occurring at appropriate temporal and spatial scales. Coral fluorescence imaging tools have the potential to improve both ecological and physiological assessments. Although fluorescence imaging is regularly used for laboratory studies of corals, it has not yet been used for large-scale in situ assessments. Current obstacles to effective underwater fluorescence surveying include limited field-of-view due to low camera sensitivity, the need for nighttime deployment because of ambient light contamination, and the need for custom multispectral narrow band imaging systems to separate the signal into meaningful fluorescence bands. Here we describe the Fluorescence Imaging System (FluorIS), based on a consumer camera modified for greatly increased sensitivity to chlorophyll-a fluorescence, and we show high spectral correlation between acquired images and in situ spectrometer measurements. This system greatly facilitates underwater wide field-of-view fluorophore surveying during both night and day, and potentially enables improvements in semi-automated segmentation of live corals in coral reef photographs and juvenile coral surveys. PMID:25582836

  10. Development of stable monolithic wide-field Michelson interferometers.

    PubMed

    Wan, Xiaoke; Ge, Jian; Chen, Zhiping

    2011-07-20

    Bulk wide-field Michelson interferometers are very useful for high precision applications in remote sensing and astronomy. A stable monolithic Michelson interferometer is a key element in high precision radial velocity (RV) measurements for extrasolar planets searching and studies. Thermal stress analysis shows that matching coefficients of thermal expansion (CTEs) is a critical requirement for ensuring interferometer stability. This requirement leads to a novel design using BK7 and LAK7 materials, such that the monolithic interferometer is free from thermal distortion. The processes of design, fabrication, and testing of interferometers are described in detail. In performance evaluations, the field angle is typically 23.8° and thermal sensitivity is typically -2.6×10(-6)/°C near 550 nm, which corresponds to ∼800 m/s/°C in the RV scale. Low-cost interferometer products have been commissioned in multiple RV instruments, and they are producing high stability performance over long term operations. PMID:21772398

  11. Wide Field-of-View Fluorescence Imaging of Coral Reefs

    NASA Astrophysics Data System (ADS)

    Treibitz, Tali; Neal, Benjamin P.; Kline, David I.; Beijbom, Oscar; Roberts, Paul L. D.; Mitchell, B. Greg; Kriegman, David

    2015-01-01

    Coral reefs globally are declining rapidly because of both local and global stressors. Improved monitoring tools are urgently needed to understand the changes that are occurring at appropriate temporal and spatial scales. Coral fluorescence imaging tools have the potential to improve both ecological and physiological assessments. Although fluorescence imaging is regularly used for laboratory studies of corals, it has not yet been used for large-scale in situ assessments. Current obstacles to effective underwater fluorescence surveying include limited field-of-view due to low camera sensitivity, the need for nighttime deployment because of ambient light contamination, and the need for custom multispectral narrow band imaging systems to separate the signal into meaningful fluorescence bands. Here we describe the Fluorescence Imaging System (FluorIS), based on a consumer camera modified for greatly increased sensitivity to chlorophyll-a fluorescence, and we show high spectral correlation between acquired images and in situ spectrometer measurements. This system greatly facilitates underwater wide field-of-view fluorophore surveying during both night and day, and potentially enables improvements in semi-automated segmentation of live corals in coral reef photographs and juvenile coral surveys.

  12. Wide-field, high-resolution Fourier ptychographic microscopy

    PubMed Central

    Zheng, Guoan; Horstmeyer, Roarke; Yang, Changhuei

    2014-01-01

    In this article, we report an imaging method, termed Fourier ptychographic microscopy (FPM), which iteratively stitches together a number of variably illuminated, low-resolution intensity images in Fourier space to produce a wide-field, high-resolution complex sample image. By adopting a wavefront correction strategy, the FPM method can also correct for aberrations and digitally extend a microscope’s depth-of-focus beyond the physical limitations of its optics. As a demonstration, we built a microscope prototype with a resolution of 0.78 μm, a field-of-view of ~120 mm2, and a resolution-invariant depth-of-focus of 0.3 mm (characterized at 632 nm). Gigapixel colour images of histology slides verify FPM’s successful operation. The reported imaging procedure transforms the general challenge of high-throughput, high-resolution microscopy from one that is coupled to the physical limitations of the system’s optics to one that is solvable through computation. PMID:25243016

  13. Wide Field Survey for Sub-Second Optical Variability

    NASA Astrophysics Data System (ADS)

    O'Donnell, Liam; Pollacco, Don

    2008-02-01

    An Andor Ixon+EMCCD was used to monitor stellar variability and search, in the optical, for transient astronomical events at high time resolution (<1 sec) over a relatively large (9-degree) area of sky. A monitoring program, which targeted a 9-degree field in Lyra, was conducted during July 2006. The detector was equipped with a wide-angle lens and mounted piggyback on a commercial telescope located at the Roque de los Muchachos observing site on the island of La Palma. The field was monitored for 5 consecutive nights with a time resolution of a tenth of a second and an unfiltered limiting magnitude of 10. At present only a handful of astronomical objects have been monitored at this time resolution and there is limited survey data for large areas of sky. It is hoped the experiment will provide statistical analysis of optical variability of astronomical sources on sub-second timescales and potentially discover high-energy transient sources. The experiment will also investigate the applicability of the current generation of EMCCD detectors for such astronomical projects.

  14. WiFeS: the wide field spectrograph

    NASA Astrophysics Data System (ADS)

    Dopita, Michael A.; Waldron, Liam E.; McGregor, Peter; Conroy, Peter; Doolan, Matthew C.; Zhelem, Ross; Bloxham, Gabe; Saunders, Will; Jones, Damien; Pfitzner, Lee

    2004-09-01

    WiFeS is a powerful integral field, double-beam, concentric, image-slicing spectrograph designed to deliver excellent thoughput, precision spectrophotometric performance and superb image quality along with wide spectral coverage throughout the 320-1000 nm wavelength region. It is currently under construction at the Research School of Astronomy and Astrophysics of the Australian National University (ANU), and will be mounted on the ANU 2.3m telescope at Siding Spring Observatory. It will provide a 25x31 arc sec field with 0.5 arc sec sampling along each of twenty five 31x1.0 arc sec slitlets. The output format is arranged to match the 4096x4096 pixel CCD detectors in each of two cameras individually optimized for the blue and the red ends of the spectrum, respectively. A process of "interleaved nod-and-shuffle" will be applied to permit quantum noise-limited sky subtraction. Using VPH gratings, spectral resolutions modes of 3000 and 7000 will be provided. The full spectral range is covered in a single exposure in the R=3000 mode, and in two exposures in the R=7000 mode. The use of transmissive coated optics, VPH gratings and optimized mirror coatings ensures a throughput (including telescope and atmosphere) that peaks above 30%. The concentric image-slicer design ensures an excellent and uniform image quality across the full field. To maximize the scientific return, the whole instrument is configured for remote observing, pipeline data reduction, and the accumulation of calibration image libraries.

  15. AC electric field induced droplet deformation in a microfluidic T-junction.

    PubMed

    Xi, Heng-Dong; Guo, Wei; Leniart, Michael; Chong, Zhuang Zhi; Tan, Say Hwa

    2016-08-01

    We present for the first time an experimental study on the droplet deformation induced by an AC electric field in droplet-based microfluidics. It is found that the deformation of the droplets becomes stronger with increasing electric field intensity and frequency. The measured electric field intensity dependence of the droplet deformation is consistent with an early theoretical prediction for stationary droplets. We also proposed a simple equivalent circuit model to account for the frequency dependence of the droplet deformation. The model well explains our experimental observations. In addition, we found that the droplets can be deformed repeatedly by applying an amplitude modulation (AM) signal. PMID:27173587

  16. Wide-Field Infrared Survey Telescope (WFIRST) Interim Report

    NASA Technical Reports Server (NTRS)

    Green, J.; Schechter, P.; Baltay, C.; Bean, R.; Bennett, D.; Brown, R.; Conselice, C.; Donahue, M.; Gaudi, S.; Lauer, T.; Perlmutter, S.; Rauscher, B.; Rhodes, J.; Roellig, T.; Stern, D.; Sumi, T.; Gerhels, N.; Sambruna, R.; Barry, R. K.; Content, D.; Grady, K; Jackson, C.; Kruk, J.; Melton, M.; Rioux, N.

    2011-01-01

    The New Worlds, New Horizons (NWNH) in Astronomy and Astrophysics 2010 Decadal Survey prioritized the community consensus for ground-based and space-based observatories. Recognizing that many of the community s key questions could be answered with a wide-field infrared survey telescope in space, and that the decade would be one of budget austerity, WFIRST was top ranked in the large space mission category. In addition to the powerful new science that could be accomplished with a wide-field infrared telescope, the WFIRST mission was determined to be both technologically ready and only a small fraction of the cost of previous flagship missions, such as HST or JWST. In response to the top ranking by the community, NASA formed the WFIRST Science Definition Team (SDT) and Project Office. The SDT was charged with fleshing out the NWNH scientific requirements to a greater level of detail. NWNH evaluated the risk and cost of the JDEM-Omega mission design, as submitted by NASA, and stated that it should serve as the basis for the WFIRST mission. The SDT and Project Office were charged with developing a mission optimized for achieving the science goals laid out by the NWNH re-port. The SDT and Project Office opted to use the JDEM-Omega hardware configuration as an initial start-ing point for the hardware implementation. JDEM-Omega and WFIRST both have an infrared imager with a filter wheel, as well as counter-dispersed moderate resolution spectrometers. The primary advantage of space observations is being above the Earth's atmosphere, which absorbs, scatters, warps and emits light. Observing from above the atmosphere enables WFIRST to obtain precision infrared measurements of the shapes of galaxies for weak lensing, infrared light-curves of supernovae and exoplanet microlensing events with low systematic errors, and infrared measurements of the H hydrogen line to be cleanly detected in the 1

  17. Propagation of magnetic avalanches in Mn12Ac at high field sweep rates.

    PubMed

    Decelle, W; Vanacken, J; Moshchalkov, V V; Tejada, J; Hernández, J M; Macià, F

    2009-01-16

    Time-resolved measurements of the magnetization reversal in single crystals of Mn12Ac in pulsed magnetic fields, at magnetic field sweep rates from 1.5 kT/s up to 7 kT/s, suggest a new process that cannot be scaled onto a deflagrationlike propagation driven by heat diffusion. The sweep rate dependence of the propagation velocity, increasing from a few 100 m/s up to the speed of sound in Mn12Ac, indicates the existence of two new regimes at the highest sweep rates, with a transition around 4 kT/s that can be understood as a magnetic deflagration-to-detonation transition. PMID:19257315

  18. PRIMO: A Wide Field Prime Focus Infrared Mosaic Camera

    NASA Astrophysics Data System (ADS)

    Fischer, D.; Bally, J.; Green, J.; Morse, J.; Probst, R.; Green, R.; Joyce, R.; Liang, M.; Arentz, R.; Reitsema, H.; Marriott, J.

    2000-12-01

    We describe a proposal for a major new facility infrared camera for the NOAO 4-m telescopes. With a half-degree field of view at prime focus, a refractive collimator-camera design, and a 1-2.5 um range, PRIMO will enable deep, wide-field infrared surveys. The need for surveys which bridge the five-magnitude gap between 2MASS and 8-10 m spectroscopic sensitivity is well established. PRIMO will enable high-latitude broadband surveys to trace the luminosity and clustering evolution of galaxies, investigations into the composition and history of young stellar populations throughout the total volume of star-forming complexes, narrow-band imaging surveys of star forming regions, and of nebulae formed in late stellar evolutionary stages. The NOAO 4-m telescopes are well suited to this role, and PRIMO will also empower US investment in Gemini and other new generation very large telescopes. By leveraging this instrument with the previous NSF investment in these telescopes, we will provide the US community with a survey facility comparable to the UK VISTA project at a fraction of the latter's cost. This project will be carried out through teaming of an accomplished university group, CU-Boulder, a national center, NOAO, and an aerospace industry partner, Ball Aerospace & Technologies Corp. Our approach is a new model for developing major ground-based astronomical instruments. The instrument concept has been developed and costed, and we meet our performance goals with a straightforward, low-risk design. The project schedule is aggressive: two years from start of funding to first light.

  19. Astrometric Calibration of Digitized Wide-Field Photographic Plates

    NASA Astrophysics Data System (ADS)

    Boyce, Peter B.; Truong, P. N.

    2006-12-01

    8000 photographic plates originally taken at Maria Mitchell Observatory from 1913 to 1996 were scanned and digitized in 2002-2003. The resulting scans are stored in TIFF format. We have investigated the use of currently existing tools to convert plate coordinates to RA and Dec to ready the scans for inclusion in the National Virtual Observatory. This involves converting the scans to FITS format and adding WCS headers. Five of the digitized images, with slightly different centers, covering 13° x 16° in Cygnus, were calibrated using the CDS Aladin program version 3.6. An initial Tangent Plane fit was produced by entering parameters applicable for the MMO plates. The images were first calibrated by parameters. The calibration was refined by matching stars images with their positions by overlaying the positions from the Bright Star Catalog. Once a reasonably accurate calibration has been determined, additional star catalogs can be used to refine the calibration. We find that the accuracy of the calibration for a Tangent Plane is not heavily dependent upon the number of stars used. Using a simple Tangent Plane model on these wide-field plates, the coordinates of objects near the edges of the plate often differ from coordinates of objects in the catalog by up to an arcminute. As a check, we also used the WCS Tools programs written by Doug Mink at the Harvard-Smithsonian CfA, and they yield the same results. A satisfactory astrometric calibration which covers the whole field will require the use of higher order polynomials. This project was supported by the NSF/REU grant AST-0354056, the NASA/AAS Small Research Grant Program and the Nantucket Maria Mitchell Association.

  20. PSF reconstruction for MUSE in wide field mode

    NASA Astrophysics Data System (ADS)

    Villecroze, R.; Fusco, Thierry; Bacon, Roland; Madec, Pierre-Yves

    2012-07-01

    The resolution of ground-based telescopes is dramatically limited by the atmospheric turbulence.. Adaptative optics (AO) is a real-time opto-mechanical approach which allows to correct for the turbulence effect and to reach the ultimate diffraction limit astronomical telescopes and their associated instrumentation. Nevertheless, the AO correction is never perfect especially when it has to deal with large Field of View (FoV). Hence, a posteriori image processing really improves the final estimation of astrophysical data. Such techniques require an accurate knowledge of the system response at any position in the FoV The purpose of this work is then the estimation of the AO response in the particular case of the MUSE [1] /GALACSI [2] instrument (a 3D mult-object spectrograph combined with a Laser-assisted wide field AO system which will be installed at the VLT in 2013). Using telemetry data coming from both AO Laser and natural guide stars, a Point Spread Function (PSF) is derived at any location of the FoV and for every wavelength of the MUSE spectrograph. This document presents the preliminary design of the MUSE WFM PSF reconstruction process. The various hypothesis and approximations are detailed and justified. A first description of the overall process is proposed. Some alternative strategies to improve the performance (in terms of computation time and storage) are described and have been implemented. Finally, after a validation of the proposed algorithm using end-to-end models, a performance analysis is conducted (with the help of a full end-to-end model). This performance analysis will help us to populate an exhaustive error budget table.

  1. Update on the Wide-field Infrared Survey Explorer (WISE)

    NASA Technical Reports Server (NTRS)

    Mainzer, Amanda K.; Eisenhardt, Peter; Wright, Edward L.; Liu, Feng-Chuan; Irace, William; Heinrichsen, Ingolf; Cutri, Roc; Duval, Valerie

    2006-01-01

    The Wide-field Infrared Survey Explorer (WISE), a NASA MIDEX mission, will survey the entire sky in four bands from 3.3 to 23 microns with a sensitivity 1000 times greater than the IRAS survey. The WISE survey will extend the Two Micron All Sky Survey into the thermal infrared and will provide an important catalog for the James Webb Space Telescope. Using 1024(sup 2) HgCdTe and Si:As arrays at 3.3, 4.7, 12 and 23 microns, WISE will find the most luminous galaxies in the universe, the closest stars to the Sun, and it will detect most of the main belt asteroids larger than 3 km. The single WISE instrument consists of a 40 cm diamond-turned aluminum afocal telescope, a two-stage solid hydrogen cryostat, a scan mirror mechanism, and reimaging optics giving 5 resolution (full-width-half-maximum). The use of dichroics and beamsplitters allows four color images of a 47' x47' field of view to be taken every 8.8 seconds, synchronized with the orbital motion to provide total sky coverage with overlap between revolutions. WISE will be placed into a Sun-synchronous polar orbit on a Delta 7320-10 launch vehicle. The WISE survey approach is simple and efficient. The three-axis-stabilized spacecraft rotates at a constant rate while the scan mirror freezes the telescope line of sight during each exposure. WISE has completed its mission Preliminary Design Review and its NASA Confirmation Review, and the project is awaiting confirmation from NASA to proceed to the Critical Design phase. Much of the payload hardware is now complete, and assembly of the payload will occur over the next year. WISE is scheduled to launch in late 2009; the project web site can be found at www.wise.ssl.berkeley.edu.

  2. Development of the wide field imager for Athena

    NASA Astrophysics Data System (ADS)

    Meidinger, Norbert; Eder, Josef; Fürmetz, Maria; Nandra, Kirpal; Pietschner, Daniel; Plattner, Markus; Rau, Arne; Reiffers, Jonas; Strecker, Rafael; Barbera, Marco; Brand, Thorsten; Wilms, Jörn

    2015-08-01

    The WFI (Wide Field Imager) instrument is planned to be one of two complementary focal plane cameras on ESA's next X-ray observatory Athena. It combines unprecedented survey power through its large field of view of 40 arcmin x 40 arcmin together with excellent count-rate capability (>= 1 Crab). The energy resolution of the silicon sensor is state-of-the-art in the energy band of interest from 0.2 keV to 15 keV, e.g. the full width at half maximum of a line at 6 keV will be <= 150 eV until the end of the nominal mission phase. This performance is accomplished by using DEPFET active pixel sensors with a pixel size of 130 μm x 130 μm well suited to the on-axis angular resolution of 5 arcsec of the mirror system. Each DEPFET pixel is a combined detector-amplifier structure with a MOSFET integrated onto a fully depleted 450 μm thick silicon bulk. Two different types of DEPFET sensors are planned for the WFI instrument: A set of four large-area sensors to cover the physical size of 14 cm x 14 cm in the focal plane and a single smaller gateable DEPFET sensor matrix optimized for high count-rate observations. Here we present the conceptual design of the instrument with focus on the critical subsystems and describe the instrument performance expectations. An outline of the model philosophy and the project organization completes the presentation.

  3. Theoretical study of electromagnetic electron cyclotron waves in the presence of AC field in Uranian magnetosphere

    NASA Astrophysics Data System (ADS)

    Pandey, R. S.; Kaur, Rajbir

    2015-10-01

    Electromagnetic electron cyclotron (EMEC) waves with temperature anisotropy in the magnetosphere of Uranus have been studied in present work. EMEC waves are investigated using method of characteristic solution by kinetic approach, in presence of AC field. In 1986, Voyager 2 encounter with Uranus revealed that magnetosphere of Uranus exhibit non-Maxwellian high-energy tail distribution. So, the dispersion relation, real frequency and growth rate are evaluated using Lorentzian Kappa distribution function. Effect of temperature anisotropy, AC frequency and number density of particles is found. The study is also extended to oblique propagation of EMEC waves in presence and absence of AC field. Through comprehensive mathematical analysis it is found that when EMEC wave propagates parallel to intrinsic magnetic field of Uranus, its growth is more enhanced than in case of oblique propagation. Results are also discussed in context to magnetosphere of Earth and also gives theoretical explanation to existence of high energetic particles observed by Voyager 2 in the magnetosphere of Uranus. The results can present a further insight into the nature of electron-cyclotron instability condition for the whistler mode waves in the outer radiation belts of Uranus or other space plasmas.

  4. Wide-Field Slitless Spectroscopy with JWST/NIRISS

    NASA Astrophysics Data System (ADS)

    Dixon, William V.; Ravindranath, Swara; Willott, Chris

    2015-08-01

    The Near Infrared Imager and Slitless Spectrograph (NIRISS) aboard the James Webb Space Telescope (JWST) will offer wide-field slitless spectroscopy (WFSS) with a resolving power R = 150 at wavelengths from 0.8 to 2.25 microns. In this band, NIRISS will be sensitive to Lyman-alpha emission lines and continuum breaks in the spectra of galaxies with redshifts 6 < z < 17, allowing it to probe the first stars and ionizing sources in the early universe. NIRISS observations of the high-redshift universe will provide a wealth of information on foreground objects, creating a unique library of optical emission-line spectra from the faintest galaxies at lower redshifts. To explore its ability to identify and characterize galaxies at all redshifts, we have modeled NIRISS observations of a massive strong-lensing galaxy cluster and analyzed the synthetic images using standard software tools. Our simulations demonstrate that WFSS with NIRISS will provide a powerful tool for the exploration of galaxies near and far.NIRISS is provided to the JWST project by the Canadian Space Agency under the leadership of René Doyon of the Université de Montréal. The prime contractor is COM DEV Canada.

  5. Metrology of confined flows using wide field nanoparticle velocimetry

    PubMed Central

    Ranchon, Hubert; Picot, Vincent; Bancaud, Aurélien

    2015-01-01

    The manipulation of fluids in micro/nanofabricated systems opens new avenues to engineer the transport of matter at the molecular level. Yet the number of methods for the in situ characterization of fluid flows in shallow channels is limited. Here we establish a simple method called nanoparticle velocimetry distribution analysis (NVDA) that relies on wide field microscopy to measure the flow rate and channel height based on the fitting of particle velocity distributions along and across the flow direction. NVDA is validated by simulations, showing errors in velocity and height determination of less than 1% and 8% respectively, as well as with experiments, in which we monitor the behavior of 200 nm nanoparticles conveyed in channels of ~1.8 μm in height. We then show the relevance of this assay for the characterization of flows in bulging channels, and prove its suitability to characterize the concentration of particles across the channel height in the context of visco-elastic focusing. Our method for rapid and quantitative flow characterization has therefore a broad spectrum of applications in micro/nanofluidics, and a strong potential for the optimization of Lab-on-Chips modules in which engineering of confined transport is necessary. PMID:25974654

  6. Hubble Space Telescope, Wide Field and Planetary Camera

    NASA Technical Reports Server (NTRS)

    1985-01-01

    In this photograph, engineers and technicians prepare the Hubble Space Telescope's (HST's) Wide Field and Planetary Camera (WF/PC) for installation at the Lockheed Missile and Space Company. The WF/PC is designed to investigate the age of the universe and to search for new planetary systems around young stars. It takes pictures of large numbers of galaxies and close-ups of planets in our solar system. The HST is the first of NASA's great observatories and the most complex and sensitive optical telescope ever made. The purpose of the HST is to study the cosmos from a low-Earth orbit by placing the telescope in space, enabling astronomers to collect data that is free of the Earth's atmosphere. The HST was deployed from the Space Shuttle Discovery (STS-31 mission) into Earth orbit in April 1990. The Marshall Space Flight Center had overall responsibility for design, development, and construction of the HST. The Perkin-Elmer Corporation, in Danbury, Cornecticut, developed the optical system and guidance sensors. The Lockheed Missile and Space Company, Sunnyvale, California, produced the protective outer shroud and spacecraft systems, and assembled and tested the finished telescope.

  7. Wide field of view multifocal scanning microscopy with sparse sampling

    NASA Astrophysics Data System (ADS)

    Wang, Jie; Wu, Jigang

    2016-02-01

    We propose to use sparsely sampled line scans with a sparsity-based reconstruction method to obtain images in a wide field of view (WFOV) multifocal scanning microscope. In the WFOV microscope, we used a holographically generated irregular focus grid to scan the sample in one dimension and then reconstructed the sample image from line scans by measuring the transmission of the foci through the sample during scanning. The line scans were randomly spaced with average spacing larger than the Nyquist sampling requirement, and the image was recovered with sparsity-based reconstruction techniques. With this scheme, the acquisition data can be significantly reduced and the restriction for equally spaced foci positions can be removed, indicating simpler experimental requirement. We built a prototype system and demonstrated the effectiveness of the reconstruction by recovering microscopic images of a U.S. Air Force target and an onion skin cell microscope slide with 40, 60, and 80% missing data with respect to the Nyquist sampling requirement.

  8. Wide-Field Slitless Spectroscopy with JWST/NIRISS

    NASA Astrophysics Data System (ADS)

    Dixon, William V.

    2013-01-01

    The Near Infrared Imager and Slitless Spectrograph (NIRISS) is one of four scientific instruments that will fly aboard the James Webb Space Telescope (JWST) later in this decade. Among its capabilities, NIRISS offers wide-field slitless spectroscopy (WFSS) with a resolving power R = 150 over the wavelength range 1.0 to 2.25 microns using a pair of grisms that disperse light in orthogonal directions. Employing the software packages aXe and Source Extractor, we have developed the configuration files needed to model WFSS observations with NIRISS and to extract and calibrate the resulting spectra. These files, together with a cookbook detailing their use, are available on the JWST/NIRISS web site at STScI. Using these tools, we construct synthetic images of the near-IR sky, identify and extract the spectra of individual sources, and demonstrate that NIRISS can observe galaxies with redshifts up to z = 17. NIRISS is provided to the JWST project by the Canadian Space Agency under the leadership of René Doyon of the Université de Montréal. The prime contractor is COM DEV Canada.

  9. Super-resolution high sensitivity AC Magnetic Field Imaging with NV Centers in Diamond

    NASA Astrophysics Data System (ADS)

    Bauch, Erik; Jaskula, Jean-Christophe; Trifonov, Alexei; Walsworth, Ronald

    2015-05-01

    The Nitrogen-Vacancy center in diamond (NV center), a defect consisting of a nitrogen atom next to a missing atom, has been successfully applied to sense magnetic field, electric field, temperature and can also be used as fluorescence marker and single photon emitter. We will present super-resolution imaging of NV centers and simultaneous sensing of AC magnetic fields with high sensitivity. To demonstrate the applicability of super-resolution magnetic field imaging, we resolve several NV centers with an optical resolution smaller than 20 nm and probe locally the gradient of a externally applied magnetic field. Additionally, we demonstrate the detection of magnetic field signals from 1H protons with subdiffraction image resolution. We will also show that our super-resolution magnetometer will benefit from a new readout method based on a spin-to-charge mapping that we have developed to increase the readout contrast.

  10. Keratinocyte galvanotaxis in combined DC and AC electric fields supports an electromechanical transduction sensing mechanism.

    PubMed

    Hart, Francis X; Laird, Mhairi; Riding, Aimie; Pullar, Christine E

    2013-02-01

    Sedentary keratinocytes at the edge of a skin wound migrate into the wound, guided by the generation of an endogenous electric field (EF) generated by the collapse of the transepithelial potential. The center of the wound quickly becomes more negative than the surrounding tissue and remains the cathode of the endogenous EF until the wound is completely re-epithelialized. This endogenous guidance cue can be studied in vitro. When placed in a direct current (DC) EF of physiological strength, 100 V/m, keratinocytes migrate directionally toward the cathode in a process known as galvanotaxis. Although a number of membrane-bound (e.g., epidermal growth factor receptor (EGFR), integrins) and cytosolic proteins (cAMP, ERK, PI3K) are known to play a role in the downstream signaling mechanisms underpinning galvanotaxis, the initial sensing mechanism for this response is not understood. To investigate the EF sensor, we studied the migration of keratinocytes in a DC EF of 100 V/m, alternating current (AC) EFs of 40 V/m at either 1.6 or 160 Hz, and combinations of DC and AC EFs. In the AC EFs alone, keratinocytes migrated randomly. The 1.6 Hz AC EF combined with the DC EF suppressed the direction of migration but had no effect on speed. In contrast, the 160 Hz AC EF combined with the DC EF did not affect the direction of migration but increased the migration speed compared to the DC EF alone. These results can be understood in terms of an electromechanical transduction model, but not an electrodiffusion/osmosis or a voltage-gated channel model. PMID:22907479

  11. Analysis of resistance to Cry1Ac in field-collected pink bollworm, Pectinophora gossypiella (Lepidoptera:Gelechiidae), populations.

    PubMed

    Ojha, Abhishek; Sree, K Sowjanya; Sachdev, Bindiya; Rashmi, M A; Ravi, K C; Suresh, P J; Mohan, Komarlingam S; Bhatnagar, Raj K

    2014-01-01

    High survivorship of pink bollworrm, Pectinophora gossypiella in bolls of Bollgard® cotton hybrids and resistance to Cry1Ac protein, expressed in Bollgard cotton were reported in field-populations collected from the state of Gujarat (western India) in 2010. We have found Cry1Ac-resistance in pink bollworm populations sourced from Bollgard and non-Bt cotton fields in the adjoining states of Maharashtra and Madhya Pradesh in Central India. Further, we observed reduced binding of labeled Cry1Ac protein to receptors localized on the brush-border membrane of pink bollworm larval strains with high tolerance to Cry1Ac. These strains were sourced from Bollgard and conventional cotton fields. A pooled Cry1Ac-resistant strain, further selected on Cry1Ac diet also showed significantly reduced binding to Cry1Ac protein. The reduced binding of Cry1Ac to receptors could be an underlying mechanism for the observed resistance in pink bollworm populations feeding on Bollgard hybrids. PMID:25523173

  12. Spin superconductivity and ac-Josephson effect in Graphene system under strong magnetic field

    NASA Astrophysics Data System (ADS)

    Liu, Haiwen; Jiang, Hua; Sun, Qing-Feng; Xie, X. C.; Collaborative Innovation Center of Quantum Matter, Beijing, China Collaboration

    We study the spin superconductivity in Graphene system under strong magnetic field. From the microscopically Gor'kov method combined with the Aharonov-Casher effect, we derive the effective Landau-Ginzburg free energy and analyze the time evolution of order parameter, which is confirmed to be the off-diagonal long range order. Meanwhile, we compare the ground state of spin superconductivity to the canted-antiferromagnetic state, and demonstrate the equivalence between these two states. Moreover, we give out the pseudo-field flux quantization condition of spin supercurrent, and propose an experimental measurable ac-Josephson effect of spin superconductivity in this system.

  13. WISH: Wide-field Imaging Durvayor for High-redshift

    NASA Astrophysics Data System (ADS)

    Yamada, Toru

    2015-08-01

    We introduce the concept and current status of WISH project and discuss the science cases. WISH is a proposed space science mission for JAXA, which is dedicated for the deep and wide-field near-infrared imaging surveys. The mission contains the 1.5m cooled telescope as well as the imager with the FoV of ~850 square arcmin. The main goal of WISH is to detect and study galaxies at z=8-15 in the earliest history of structure formation in the universe. The key feature is to conduct WISH Ultra Deep Survey, which images in total of 100 square degrees in 6 broad-band filters at 0.9-4.5 micron down to 28AB magnitude. While more than 10^5 galaxies at z=8-9, 10^4 galaxies at z=11-12 will be detected, WISH-UDS is designed to constrain UV luminosity function at z=15. Depending on the models of the earliest evolution history, 1-1000 galaxies at z~15 (~100 galaxies for the moderate cases) will be detected. The UV spectral properties as well as the clustering properties of galaxies at z=8-15 can be studied as well; UV slope can be measured up to z=15, and the stellar and dark-matter-halo masses can be obtained up to z=9. WISH UDS can provide excellent opportunities for studying SNe at high redshift. Up to ~7000 type Ia SNe at z>1 can be detected and the distance modulus can be constrained with the precision of 0.9-1.5% at z>1.5. More than 100 Super Luminous SNe at z>6, and 10 SLSN at z>10 can also be detected, which allow us to study the earliest history of massive star formation in the universe. WISH imaging surveys as well as WISHSpec, which is an optional parallel-operation simple IFU spectrograph, also provide unique opportunities in various astronomical fields. WISH mission proposal was submitted to JAXA in February 2015 for the first down selection of JAXA Large Strategic Science Mission targeting the launch date in 2020-22. International collaborations including SAO (G.Fazio et al.), LAM (D. Burgarella et al.) and Canada (M.Sawicki et al.) are also actively coordinated.

  14. AC-field-induced quantum phase transitions in density of states

    NASA Astrophysics Data System (ADS)

    Yang, Kai-Hua; Liu, Kai-Di; Wang, Huai-Yu; Qin, Chang-Dong

    2016-02-01

    We investigate the joint effects of the intralead electron interaction and an external alternating gate voltage on the time-averaged local density of states (DOSs) of a quantum dot coupled to two Luttinger-liquid leads in the Kondo regime. A rich dependence of the DOSs on the driving amplitude and intralead interaction is demonstrated. We show that the feature is quite different for different interaction strengths in the presence of the ac field. It is shown that the photon-assisted transport processes cause an additional splitting of the Kondo peak or dip, which exhibits photon-assisted single-channel (1CK) or two-channel Kondo (2CK) physics behavior. The phase transition between photon-assisted 1CK and 2CK physics occurs when the interaction strength is moderately strong. The inelastic channels associated with photon-assisted electron tunneling can dominate electron transport for weak interaction when the ac amplitude is greater than the frequency by one order of magnitude. In the limit of strong interaction the DOSs scale as a power-law behavior which is strongly affected by the ac field.

  15. Dynamic melting and impurity particle tracking in continuously adjustable AC magnetic field

    NASA Astrophysics Data System (ADS)

    Bojarevics, V.; Pericleous, K.

    2016-07-01

    The analysis of semi-levitation melting is extended to account for the presence of particles (impurities, broken metal dendrite agglomerates, bubbles) during the full melting cycle simulated numerically using the pseudo-spectral schemes. The AC coil is dynamically moving with the melt front progress, while the generated Joule heat serves to enhance the melting rate. The electromagnetic force is decomposed into the time average and the oscillating parts. The time average effects on the particle transport are investigated previously using approximations derived for a locally uniform magnetic field. This paper presents expressions for the skin-layer type of the AC force containing also the pulsating part which contributes to the particle drag by the ‘history’ and ‘added mass’ contributions. The intense turbulence in the bulk of molten metal additionally contributes to the particle dispersion. The paper attempts to demonstrate the importance of each of the mentioned effects onto the particle transport during the melting until the final pouring stage. The method could be extended to similar AC field controlled melting/solidification processes.

  16. MIRIS: A Compact Wide-field Infrared Space Telescope

    NASA Astrophysics Data System (ADS)

    Han, Wonyong; Lee, Dae-Hee; Jeong, Woong-Seob; Park, Youngsik; Moon, Bongkon; Park, Sung-Joon; Pyo, Jeonghyun; Kim, Il-Joong; Park, Won-Kee; Lee, Dukhang; Seon, Kwang-Il; Nam, Uk-Won; Cha, Sang-Mok; Park, Kwijong; Park, Jang-Hyun; Yuk, In-Soo; Ree, Chang Hee; Jin, Ho; Choel Yang, Sun; Park, Hong-Young; Shin, Goo-Hwan; Seo, Joung-Ki; Rhee, Seung-Wu; Park, Jong-Oh; Lee, Hyung Mok; Murakami, Hiroshi; Matsumoto, Toshio

    2014-09-01

    A compact infrared space telescope called MIRIS (Multi-purpose Infra-Red Imaging System) was developed by the Korea Astronomy and Space Science Institute (KASI), and launched onboard the Science and Technology Satellite-3 of Korea (STSAT-3) in 2013 November. The main mission of MIRIS is the Paschen-α emission line survey along the Galactic plane and the cosmic infrared background (CIB) observation, particularly around the north ecliptic pole region. For these missions, a wide field of view (3.67 × 3.67°) with an angular resolution of 51.6'' and wavelength coverage from 0.9 ~ 2.0 μm have been adopted for MIRIS, having optical components consisting of a 80 mm main lens and four other lenses with F/2 focal ratio optics. The opto-mechanical system was carefully designed to minimize any effects from shock during the launch process and thermal variation. Also, the telescope was designed to use a passive cooling technique to maintain the temperature around 200 K in order to reduce thermal noise. A micro Stirling cooler was used to cool down the Teledyne PICNIC infrared array to 90 K, which was equipped in a dewar with four filters for infrared passbands of I, H, and Paschen-α and a dual-band continuum line filter. MIRIS system was integrated into the STSAT-3 as its primary payload and successfully passed required tests in the laboratory, such as thermal-vacuum, vibration, and shock tests. MIRIS is now operating in sun synchronous orbits for initial tests and has observed its first images successfully.

  17. 3D defect detection using optical wide-field microscopy

    NASA Astrophysics Data System (ADS)

    Tympel, Volker; Schaaf, Marko; Srocka, Bernd

    2007-06-01

    We report a method to detect signed differences in two similar data sets representing 3-dimensional intensity profiles recorded by optical wide-field microscopes. The signed differences describe missing or unexpected intensity values, defined as defects. In technical applications like wafer and mask inspection, data sets often represent surfaces. The reported method is able to describe the size and position especially in relation to the neighboring surface and is called Three-Dimension-Aberration (TDA)-Technology. To increase the tool performance and to handle different sizes of defects a scaled bottom-up method is implemented and started with high reduced data sets for the search of large defects. Each analysis contains three steps. The first step is a correlation to calculate the displacement vector between the similar data sets. In the second step a new data set is created. The new data set consists of intensity differences. Extreme values in the data set represent the position of defects. By the use of linear and non-linear filters the stability of detection can be improved. If all differences are below a threshold the bottom-up method starts with the next larger scaled data set. In the other case it is assumed that the defect is detected and step three starts with the detection of the convex hull of the defect and the search of the neighboring surface. As a result the defect is described by a parameter set including the relative position. Because of the layered structure of the data set and the bottom-up technique the method is suitable for multi-core processor architectures.

  18. Wide-Field Optic for Autonomous Acquisition of Laser Link

    NASA Technical Reports Server (NTRS)

    Page, Norman A.; Charles, Jeffrey R.; Biswas, Abhijit

    2011-01-01

    An innovation reported in Two-Camera Acquisition and Tracking of a Flying Target, NASA Tech Briefs, Vol. 32, No. 8 (August 2008), p. 20, used a commercial fish-eye lens and an electronic imaging camera for initially locating objects with subsequent handover to an actuated narrow-field camera. But this operated against a dark-sky background. An improved solution involves an optical design based on custom optical components for the wide-field optical system that directly addresses the key limitations in acquiring a laser signal from a moving source such as an aircraft or a spacecraft. The first challenge was to increase the light collection entrance aperture diameter, which was approximately 1 mm in the first prototype. The new design presented here increases this entrance aperture diameter to 4.2 mm, which is equivalent to a more than 16 times larger collection area. One of the trades made in realizing this improvement was to restrict the field-of-view to +80 deg. elevation and 360 azimuth. This trade stems from practical considerations where laser beam propagation over the excessively high air mass, which is in the line of sight (LOS) at low elevation angles, results in vulnerability to severe atmospheric turbulence and attenuation. An additional benefit of the new design is that the large entrance aperture is maintained even at large off-axis angles when the optic is pointed at zenith. The second critical limitation for implementing spectral filtering in the design was tackled by collimating the light prior to focusing it onto the focal plane. This allows the placement of the narrow spectral filter in the collimated portion of the beam. For the narrow band spectral filter to function properly, it is necessary to adequately control the range of incident angles at which received light intercepts the filter. When this angle is restricted via collimation, narrower spectral filtering can be implemented. The collimated beam (and the filter) must be relatively large to

  19. The Software Design for the Wide-Field Infrared Explorer Attitude Control System

    NASA Technical Reports Server (NTRS)

    Anderson, Mark O.; Barnes, Kenneth C.; Melhorn, Charles M.; Phillips, Tom

    1998-01-01

    The Wide-Field Infrared Explorer (WIRE), currently scheduled for launch in September 1998, is the fifth of five spacecraft in the NASA/Goddard Small Explorer (SMEX) series. This paper presents the design of WIRE's Attitude Control System flight software (ACS FSW). WIRE is a momentum-biased, three-axis stabilized stellar pointer which provides high-accuracy pointing and autonomous acquisition for eight to ten stellar targets per orbit. WIRE's short mission life and limited cryogen supply motivate requirements for Sun and Earth avoidance constraints which are designed to prevent catastrophic instrument damage and to minimize the heat load on the cryostat. The FSW implements autonomous fault detection and handling (FDH) to enforce these instrument constraints and to perform several other checks which insure the safety of the spacecraft. The ACS FSW implements modules for sensor data processing, attitude determination, attitude control, guide star acquisition, actuator command generation, command/telemetry processing, and FDH. These software components are integrated with a hierarchical control mode managing module that dictates which software components are currently active. The lowest mode in the hierarchy is the 'safest' one, in the sense that it utilizes a minimal complement of sensors and actuators to keep the spacecraft in a stable configuration (power and pointing constraints are maintained). As higher modes in the hierarchy are achieved, the various software functions are activated by the mode manager, and an increasing level of attitude control accuracy is provided. If FDH detects a constraint violation or other anomaly, it triggers a safing transition to a lower control mode. The WIRE ACS FSW satisfies all target acquisition and pointing accuracy requirements, enforces all pointing constraints, provides the ground with a simple means for reconfiguring the system via table load, and meets all the demands of its real-time embedded environment (16 MHz Intel

  20. The ac and dc electric field meters developed for the US Department of Energy

    NASA Technical Reports Server (NTRS)

    Kirkham, H.; Johnston, A.; Jackson, S.; Sheu, K.

    1987-01-01

    Two space-potential electric field meters developed at the Jet Propulsion Laboratory under the auspices of the U.S. Department of Energy are described. One of the meters was designed to measure dc fields, the other ac fields. Both meters use fiber optics to couple a small measuring probe to a remote readout device, so as to minimize field perturbation due to the presence of the probe. By using coherent detection, it has been possible to produce instruments whose operating range extends from about 10 V/m up to about 2.5 kV/cm, without the need for range switching on the probe. The electrical and mechanical design of both meters are described in detail. Data from laboratory tests are presented, as well as the results of the tests at the National Bureau of Standards and the Electric Power Research Institute's High Voltage Transmission Research Facility.

  1. Hot electrons injection in carbon nanotubes under the influence of quasi-static ac-field

    NASA Astrophysics Data System (ADS)

    Amekpewu, M.; Mensah, S. Y.; Musah, R.; Mensah, N. G.; Abukari, S. S.; Dompreh, K. A.

    2016-07-01

    The theory of hot electrons injection in carbon nanotubes (CNTs) where both dc electric field (Ez), and a quasi-static ac field exist simultaneously (i.e. when the frequency ω of ac field is much less than the scattering frequency v (ω ≪ v or ωτ ≪ 1, v =τ-1) where τ is relaxation time) is studied. The investigation is done theoretically by solving semi-classical Boltzmann transport equation with and without the presence of the hot electrons source to derive the current densities. Plots of the normalized current density versus dc field (Ez) applied along the axis of the CNTs in the presence and absence of hot electrons reveal ohmic conductivity initially and finally negative differential conductivity (NDC) provided ωτ ≪ 1 (i.e. quasi- static case). With strong enough axial injection of the hot electrons, there is a switch from NDC to positive differential conductivity (PDC) about Ez ≥ 75 kV / cm and Ez ≥ 140 kV / cm for a zigzag CNT and an armchair CNT respectively. Thus, the most important tough problem for NDC region which is the space charge instabilities can be suppressed due to the switch from the NDC behaviour to the PDC behaviour predicting a potential generation of terahertz radiations whose applications are relevance in current-day technology, industry, and research.

  2. Self-field ac losses in biaxially aligned Y{endash}Ba{endash}Cu{endash}O tape conductors

    SciTech Connect

    Iijima, Y.; Hosaka, M.; Sadakata, N.; Saitoh, T.; Kohno, O.; Takeda, K.

    1997-11-01

    Self-field ac losses were measured by the conventional ac four-probe method in biaxially aligned Y{endash}Ba{endash}Cu{endash}O tapes using polycrystalline Hastelloy tapes with textured yttria-stabilized-zirconia buffer layers. The ac losses increased in proportion to the fourth power of transport current in the high J{sub c} sample, and agreed well with Norris{close_quote} equation for thin strip conductors. However, the low J{sub c} sample had rather higher losses than Norris{close_quote} prediction, suggesting excessive magnetic flux penetration caused by percolated current paths. The results confirmed Norris{close_quote} prediction of the low ac losses for thin strip conductors, and indicated the importance of removing percolated structures of current paths to avoid higher ac losses than the theoretical predictions based on uniform conductors. {copyright} {ital 1997 American Institute of Physics.}

  3. Stretching of long DNA molecules in the microvortex induced by laser and ac electric field

    NASA Astrophysics Data System (ADS)

    Nakano, Michihiko; Kurita, Hirofumi; Komatsu, Jun; Mizuno, Akira; Katsura, Shinji

    2006-09-01

    A microvortex is generated around an infrared laser focus where an intense ac electric field is applied. The authors used this optoelectrostatic microvortex for stretching individual long DNAs. When λ-or T4-phage DNA molecules were introduced into the optoelectrostatic microvortex, they were stretched around the laser focus. In addition, especially for longer T4 DNA molecules, it was possible to keep it in stretching form for more than 30s. Using this method, length of DNA molecules can be measured without fixing to a substrate. This method can be applied to DNA molecules longer than about 10μm.

  4. Magnetic fluid hyperthermia (MFH): Cancer treatment with AC magnetic field induced excitation of biocompatible superparamagnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Jordan, Andreas; Scholz, Regina; Wust, Peter; Fähling, Horst; Felix, Roland

    1999-07-01

    The story of hyperthermia with small particles in AC magnetic fields started in the late 1950s, but most of the studies were unfortunately conducted with inadequate animal systems, inexact thermometry and poor AC magnetic field parameters, so that any clinical implication was far behind the horizon. More than three decades later, it was found, that colloidal dispersions of superparamagnetic (subdomain) iron oxide nanoparticles exhibit an extraordinary specific absorption rate (SAR [ W/ g]), which is much higher at clinically tolerable H 0 f combinations in comparison to hysteresis heating of larger multidomain particles. This was the renaissance of a cancer treatment method, which has gained more and more attention in the last few years. Due to the increasing number of randomized clinical trials preferentially in Europe with conventional E-field hyperthermia systems, the general medical and physical experience in hyperthermia application is also rapidly growing. Taking this increasing clinical experience carefully into account together with the huge amount of new biological data on heat response of cells and tissues, the approach of magnetic fluid hyperthermia (MFH) is nowadays more promising than ever before. The present contribution reviews the current state of the art and some of the future perspectives supported by advanced methods of the so-called nanotechnology.

  5. AC transport in p-Ge/GeSi quantum well in high magnetic fields

    SciTech Connect

    Drichko, I. L.; Malysh, V. A.; Smirnov, I. Yu.; Golub, L. E.; Tarasenko, S. A.; Suslov, A. V.; Mironov, O. A.; Kummer, M.; Känel, H. von

    2014-08-20

    The contactless surface acoustic wave technique is implemented to probe the high-frequency conductivity of a high-mobility p-Ge/GeSi quantum well structure in the regime of integer quantum Hall effect (IQHE) at temperatures 0.3–5.8 K and magnetic fields up to 18 T. It is shown that, in the IQHE regime at the minima of conductivity, holes are localized and ac conductivity is of hopping nature and can be described within the “two-site” model. The analysis of the temperature and magnetic-field-orientation dependence of the ac conductivity at odd filing factors enables us to determine the effective hole g-factor, |g{sub zz}|≈4.5. It is shown that the in-plane component of the magnetic field leads to a decrease in the g-factor as well as increase in the cyclotron mass, which is explained by orbital effects in the complex valence band of germanium.

  6. Enhancement of the thermoelectric figure of merit in a quantum dot due to external ac field

    NASA Astrophysics Data System (ADS)

    Chen, Qiao; Wang, Zhi-yong; Xie, Zhong-Xiang

    2013-08-01

    We investigate the figure of merit of a quantum dot (QD) system irradiated with an external microwave filed by nonequilibrium Green's function (NGF) technique. Results show that the frequency of microwave field influence the figure of merit ZT significantly. At low temperature, a sharp peak can be observed in the figure of merit ZT as the frequency of ac field increases. As the frequency varies, several zero points and resonant peaks emerge in the figure of merit ZT. By adjusting the frequency of the microwave field, we can obtain high ZT. The figure of merit ZT increases with the decreasing of linewidth function Γ. In addition, Wiedemann-Franz law does not hold, particularly in the low frequency region due to multi-photon emission and absorption. Some novel thermoelectric properties are also found in two-level QD system.

  7. Orientation and Pearl-Chain Formation of Paramecia Induced by AC Electric Field

    NASA Astrophysics Data System (ADS)

    Hatakeyama, Toyomasa; Tanji, Ayafumi; Yagi, Hiroshi

    1987-11-01

    Paramecium deciliated with ethanol is able to orient itself in a parallel (positive orientation) or perpendicular direction (negative orientation) to an AC electric field, depending upon the applied frequency. We found that this turnover frequency is between 1 and 10 MHz in a non-electrolyte solution for the cells. The cells also aggregate with one another by the mutual dielectrophoresis in the electric field, provided the distance between the two cells is shorter than about half their length. The two critical field intensities for the orientation and for the aggregation cannot be clearly distinguished. Consequently, when the cell density in the solution is sufficiently high, a positive or negative pearl-chain of the cells is formed, depending upon the applied frequency.

  8. Test Results of the AC Field Measurements of Fermilab Booster Corrector Magnets

    SciTech Connect

    DiMarco, E.Joseph; Harding, D.J.; Kashikhin, V.S.; Kotelnikov, S.K.; Lamm, M.J.; Makulski, A.; Nehring, R.; Orris, D.F.; Schlabach, P.; Sylvester, C.; Tartaglia, Michael Albert; /Fermilab

    2008-06-25

    Multi-element corrector magnets are being produced at Fermilab that enable correction of orbits and tunes through the entire cycle of the Booster, not just at injection. The corrector package includes six different corrector elements--normal and skew orientations of dipole, quadrupole, and sextupole--each independently powered. The magnets have been tested during typical AC ramping cycles at 15Hz using a fixed coil system to measure the dynamic field strength and field quality. The fixed coil is comprised of an array of inductive pick-up coils around the perimeter of a cylinder which are sampled simultaneously at 100 kHz with 24-bit ADC's. The performance of the measurement system and a summary of the field results are presented and discussed.

  9. SHELS: Complete Redshift Surveys of Two Widely Separated Fields

    NASA Astrophysics Data System (ADS)

    Geller, Margaret J.; Hwang, Ho Seong; Dell’Antonio, Ian P.; Zahid, Harus Jabran; Kurtz, Michael J.; Fabricant, Daniel G.

    2016-05-01

    The Smithsonian Hectospec Lensing Survey (SHELS) is a complete redshift survey covering two well-separated fields (F1 and F2) of the Deep Lens Survey (DLS). Both fields are more than 94% complete to a Galactic extinction corrected R 0 = 20.2. Here, we describe the redshift survey of the F1 field centered at R.A.2000 = 00h53m25.ˢ3 and decl.2000 = 12°33‧55″ like F2, the F1 field covers ˜4 deg2. The redshift survey of the F1 field includes 9426 new galaxy redshifts measured with Hectospec on the MMT (published here). As a guide to future uses of the combined survey, we compare the mass metallicity relation and the distributions of D n 4000 as a function of stellar mass and redshift for the two fields. The mass–metallicity relations differ by an insignificant 1.6σ. For galaxies in the stellar mass range 1010–1011 M ⊙, the increase in the star-forming fraction with redshift is remarkably similar in the two fields. The seemingly surprising 31%–38% difference in the overall galaxy counts in F1 and F2 is probably consistent with the expected cosmic variance given the subtleties of the relative systematics in the two surveys. We also review the DLS cluster detections in the two fields: poorer photometric data for F1 precluded secure detection of the single massive cluster at z = 0.35 that we find in SHELS. Taken together, the two fields include 16,055 redshifts for galaxies with {R}0≤slant 20.2 and 20,754 redshifts for galaxies with R ≤ 20.6. These dense surveys in two well-separated fields provide a basis for future investigations of galaxy properties and large-scale structure.

  10. SHELS: Complete Redshift Surveys of Two Widely Separated Fields

    NASA Astrophysics Data System (ADS)

    Geller, Margaret J.; Hwang, Ho Seong; Dell’Antonio, Ian P.; Zahid, Harus Jabran; Kurtz, Michael J.; Fabricant, Daniel G.

    2016-05-01

    The Smithsonian Hectospec Lensing Survey (SHELS) is a complete redshift survey covering two well-separated fields (F1 and F2) of the Deep Lens Survey (DLS). Both fields are more than 94% complete to a Galactic extinction corrected R 0 = 20.2. Here, we describe the redshift survey of the F1 field centered at R.A.2000 = 00h53m25.ˢ3 and decl.2000 = 12°33‧55″ like F2, the F1 field covers ∼4 deg2. The redshift survey of the F1 field includes 9426 new galaxy redshifts measured with Hectospec on the MMT (published here). As a guide to future uses of the combined survey, we compare the mass metallicity relation and the distributions of D n 4000 as a function of stellar mass and redshift for the two fields. The mass–metallicity relations differ by an insignificant 1.6σ. For galaxies in the stellar mass range 1010–1011 M ⊙, the increase in the star-forming fraction with redshift is remarkably similar in the two fields. The seemingly surprising 31%–38% difference in the overall galaxy counts in F1 and F2 is probably consistent with the expected cosmic variance given the subtleties of the relative systematics in the two surveys. We also review the DLS cluster detections in the two fields: poorer photometric data for F1 precluded secure detection of the single massive cluster at z = 0.35 that we find in SHELS. Taken together, the two fields include 16,055 redshifts for galaxies with {R}0≤slant 20.2 and 20,754 redshifts for galaxies with R ≤ 20.6. These dense surveys in two well-separated fields provide a basis for future investigations of galaxy properties and large-scale structure.

  11. Influence of the ac magnetic field frequency on the magnetoimpedance of amorphous wire

    NASA Astrophysics Data System (ADS)

    Chen, A. P.; García, C.; Zhukov, A.; Domínguez, L.; Blanco, J. M.; González, J.

    2006-05-01

    Experimental and theoretical studies on the influence of ac magnetic field frequency on the axial diagonal (ζzz) and off-diagonal (ζphiz) components of the magnetoimpedance (MI) tensor in (Co0.94Fe0.06)72.5Si12.5B15 amorphous wires have been performed. The frequency (f) of an ac current flowing along the wire was varied from 1 to 20 MHz with the current amplitude less than 15 mA. In order to enhance the ζphiz component, the amorphous wire was submitted to torsion annealing for developing and preserving a helical magnetic anisotropy in the surface of the wire. The experimental measurements show that the value of the impedance is proportional to the square-root of the ac current frequency, \\sqrt f , in the vicinity of Hex < HK and this increase is due to the contribution of the resistance (real part of the impedance). The measurements also indicate that the peaks of the MI curve shift slightly towards higher field values with increasing f. In a theoretical study the magnetoimpedance expressions ζzz and ζphiz have been deduced using the Faraday law in combination with the solutions of the Maxwell and Landau-Lifshitz-Gilbert (LLG) equations. By analysing quantitatively the spectra of ζzz and ζphiz, the phenomenon of the shift in the peaks of the MI curve with f has been considered as a characteristic of the helical anisotropy in the domain structure of the wire surface.

  12. A fast, wide field of view, catadioptric telescope for Whipple

    NASA Astrophysics Data System (ADS)

    McGuire, James P.

    2014-12-01

    We describe the optical design of a spaceborne f/1.3 catadioptric telescope with a 9 degree field and 77 cm aperture that is being proposed to study objects in the Kuiper belt, Sedna Region, and Oort cloud.

  13. Simulation of thermal fields using different types of wide burnishing

    NASA Astrophysics Data System (ADS)

    Bobrovskij, N. M.; Melnikov, P. A.; Grigoriev, S. N.; Bobrovskij, I. N.

    2015-09-01

    The article features simulation of heat build-up in the tool while treatment using different types wide burnishing. The understanding of conditions of heat build-up and heat distribution and the quantitative estimation on the finishing stages of part's treatment is always challenging, because there is a possibility of negative and nonreciprocal effect onto the development of performance properties of treated parts. This issue gains particular importance during treatment, including burnishing using no means of lubrication.

  14. Fokker-Planck equation with arbitrary dc and ac fields: continued fraction method.

    PubMed

    Lee, Chee Kong; Gong, Jiangbin

    2011-07-01

    The continued fraction method (CFM) is used to solve the Fokker-Planck equation with arbitrary dc and ac fields. With an appropriate choice of basis functions, the Fokker-Planck equation is converted into a set of linear algebraic equations with short-ranged coupling and then CFM is implemented to obtain numerical solutions with high efficiency. Both a proposed perturbative CFM and the numerically exact matrix CFM are used to study the nonlinear response of driven systems, with their results compared to assess the validity regime of the perturbative approach. The proposed perturbative CFM approach needs scalar quantities only and hence is more efficient within its validity regime. Two nonlinear systems of different nature are used as examples: molecular dipole (rotational Brownian motion) and particle in a periodic potential (translational Brownian motion). The associated full dynamics is presented in the compact form of hysteresis loops. It is observed that as the strength of an AC driving field increases, pronounced nonlinear effects are manifested in the deformation of the hysteresis loops. PMID:21867110

  15. Development of the wide-field IFU PPak

    NASA Astrophysics Data System (ADS)

    Kelz, Andreas; Verheijen, Marc; Roth, Martin M.; Laux, Uwe; Bauer, Svend-Marian

    2004-09-01

    PPak is a new fiber-bundle, developed at the Astrophysical Institute Potsdam for the existing PMAS 3D-instrument. The intention of PPak is to provide a large integral field-of-view in combination with a large collecting area per fiber for the study of extended low-surface brightness objects. The PPak system consists of a focal reducer lens and a fiber bundle, featuring an innovative design with object, sky and calibration fibers. With a field-of-view of 74 x 65 arcseconds, PPak currently is the world's widest integral field unit that provides a semi-contiguous regular sampling of extended astronomical objects. Its pre-optics and fiber-diameter, combined with the versatility and efficiency of the PMAS spectrograph, allows PPak to make a unique trade-off between total light-collecting power and spectral resolution.

  16. Modeling of Nanoparticle-Mediated Electric Field Enhancement Inside Biological Cells Exposed to AC Electric Fields

    NASA Astrophysics Data System (ADS)

    Tiwari, Pawan K.; Kang, Sung Kil; Kim, Gon Jun; Choi, Jun; Mohamed, A.-A. H.; Lee, Jae Koo

    2009-08-01

    We present in this article the effect of alternating electric field at kilohertz (kHz) and megahertz (MHz) frequencies on the biological cells in presence and absence of nanoparticles. The induced electric field strength distribution in the region around cell membrane and nucleus envelope display different behavior at kHz and MHz frequencies. The attachment of gold nanoparticles (GNPs), especially gold nanowires around the surface of nucleus induce enhanced electric field strengths. The induced field strengths are dependent on the length of nanowire and create varying field regions when the length of nanowire is increased from 2 to 4 µm. The varying nanowire length increased the induced field strengths inside nucleoplasm and region adjacent to the nucleus in the cytoplasm. We investigated a process of electrostatic disruption of nucleus membrane when the induced electric field strength across the nucleus exceeds its tensile strength.

  17. Field Evolved Resistance in Helicoverpa armigera (Lepidoptera: Noctuidae) to Bacillus thuringiensis Toxin Cry1Ac in Pakistan

    PubMed Central

    Alvi, Anwaar H. K.; Sayyed, Ali H.; Naeem, Muhammad; Ali, Muhammad

    2012-01-01

    Helicoverpa armigera (Hübner) is one of the most destructive pests of several field and vegetable crops, with indiscriminate use of insecticides contributing to multiple instances of resistance. In the present study we assessed whether H. armigera had developed resistance to Bt cotton and compared the results with several conventional insecticides. Furthermore, the genetics of resistance was also investigated to determine the inheritance to Cry1Ac resistance. To investigate the development of resistance to Bt cotton, and selected foliar insecticides, H. armigera populations were sampled in 2010 and 2011 in several cotton production regions in Pakistan. The resistance ratios (RR) for Cry1Ac, chlorpyrifos, profenofos, cypermethrin, spinosad, indoxacarb, abamectin and deltamethrin were 580-fold, 320-, 1110-, 1950-, 200-, 380, 690, and 40-fold, respectively, compared with the laboratory susceptible (Lab-PK) population. Selection of the field collected population with Cry1Ac in 2010 for five generations increased RR to 5440-fold. The selection also increased RR for deltamethrin, chlorpyrifos, profenofos, cypermethrin, spinosad, indoxacarb, abamectin to 125-folds, 650-, 2840-, 9830-, 370-, 3090-, 1330-fold. The estimated LC50s for reciprocal crosses were 105 µg/ml (Cry1Ac-SEL female × Lab-PK male) and 81 g µg/ml (Lab-PK female × Cry1Ac-SEL male) suggesting that the resistance to Cry1Ac was autosomal; the degree of dominance (DLC) was 0.60 and 0.57 respectively. Mixing of enzyme inhibitors significantly decreased resistance to Cry1Ac suggesting that the resistance to Cry1Ac and other insecticides tested in the present study was primarily metabolic. Resistance to Cry1Ac was probably due to a single but unstable factor suggesting that crop rotation with non-Bt cotton or other crops could reduce the selection pressure for H. armigera and improve the sustainability of Bt cotton. PMID:23077589

  18. Field evolved resistance in Helicoverpa armigera (Lepidoptera: Noctuidae) to Bacillus thuringiensis toxin Cry1Ac in Pakistan.

    PubMed

    Alvi, Anwaar H K; Sayyed, Ali H; Naeem, Muhammad; Ali, Muhammad

    2012-01-01

    Helicoverpa armigera (Hübner) is one of the most destructive pests of several field and vegetable crops, with indiscriminate use of insecticides contributing to multiple instances of resistance. In the present study we assessed whether H. armigera had developed resistance to Bt cotton and compared the results with several conventional insecticides. Furthermore, the genetics of resistance was also investigated to determine the inheritance to Cry1Ac resistance. To investigate the development of resistance to Bt cotton, and selected foliar insecticides, H. armigera populations were sampled in 2010 and 2011 in several cotton production regions in Pakistan. The resistance ratios (RR) for Cry1Ac, chlorpyrifos, profenofos, cypermethrin, spinosad, indoxacarb, abamectin and deltamethrin were 580-fold, 320-, 1110-, 1950-, 200-, 380, 690, and 40-fold, respectively, compared with the laboratory susceptible (Lab-PK) population. Selection of the field collected population with Cry1Ac in 2010 for five generations increased RR to 5440-fold. The selection also increased RR for deltamethrin, chlorpyrifos, profenofos, cypermethrin, spinosad, indoxacarb, abamectin to 125-folds, 650-, 2840-, 9830-, 370-, 3090-, 1330-fold. The estimated LC(50s) for reciprocal crosses were 105 µg/ml (Cry1Ac-SEL female × Lab-PK male) and 81 g µg/ml (Lab-PK female × Cry1Ac-SEL male) suggesting that the resistance to Cry1Ac was autosomal; the degree of dominance (D(LC)) was 0.60 and 0.57 respectively. Mixing of enzyme inhibitors significantly decreased resistance to Cry1Ac suggesting that the resistance to Cry1Ac and other insecticides tested in the present study was primarily metabolic. Resistance to Cry1Ac was probably due to a single but unstable factor suggesting that crop rotation with non-Bt cotton or other crops could reduce the selection pressure for H. armigera and improve the sustainability of Bt cotton. PMID:23077589

  19. Wide field snapshot imaging polarimeter using modified Savart plates

    NASA Astrophysics Data System (ADS)

    Saito, Naooki; Odate, Satoru; Otaki, Katsura; Kubota, Masahiro; Kitahara, Rintaro; Oka, Kazuhiko

    2013-09-01

    Without moving parts, the snapshot imaging polarimeter utilizing Savart plates is capable of stable and fast measurements of spatiallly distributed Stokes parameters. To increase feasibility of the optical design, we propose modi cations that enable a wider eld-of view. By changing the Savar plates' con guration and improving the calibration procedure, the unwanted effects associated with the increase in the eld of view can be reduced. We carried out the veri cation experiments of the wide eld of view snapshot imaging polarimeter.

  20. Fundamental study of flow field generated by rotorcraft blades using wide-field shadowgraph

    NASA Technical Reports Server (NTRS)

    Parthasarathy, S. P.; Cho, Y. I.; Back, L. H.

    1985-01-01

    The vortex trajectory and vortex wake generated by helicopter rotors are visualized using a wide-field shadowgraph technique. Use of a retro-reflective Scotchlite screen makes it possible to investigate the flow field generated by full-scale rotors. Tip vortex trajectories are visible in shadowgraphs for a range of tip Mach number of 0.38 to 0.60. The effect of the angle of attack is substantial. At an angle of attack greater than 8 degrees, the visibility of the vortex core is significant even at relatively low tip Mach numbers. The theoretical analysis of the sensitivity is carried out for a rotating blade. This analysis demonstrates that the sensitivity decreases with increasing dimensionless core radius and increases with increasing tip Mach number. The threshold value of the sensitivity is found to be 0.0015, below which the vortex core is not visible and above which it is visible. The effect of the optical path length is also discussed. Based on this investigation, it is concluded that the application of this wide-field shadowgraph technique to a large wind tunnel test should be feasible. In addition, two simultaneous shadowgraph views would allow three-dimensional reconstruction of vortex trajectories.

  1. ac losses and field and current density distribution during a full cycle of a stack of superconducting tapes

    NASA Astrophysics Data System (ADS)

    Yuan, Weijia; Campbell, A. M.; Coombs, T. A.

    2010-05-01

    Starting from an existing model by Clem et al., this paper has analyzed how the current density and magnetic field distribution of a stack of superconducting tapes with ac transport currents or applied fields will change in a full cycle. This paper assumes when the ac current or field starts to change in the other direction, a new penetrated region will begin to penetrate from the superconductor surface. If we assume Jc is constant in the critical region, this paper demonstrates that the Claassen formula (7) can be used to calculate the exact ac losses. If Jc depends on local Bz, we can use Eq. (9) to quickly predict the ac losses. This approach does not need to calculate a complete ac cycle. This saves considerably computation time while gives a result which is in close agreement with that calculated from a complete ac cycle. The calculation method can be applied for calculating a superconducting pancake coil if the coil radius is much larger than the tape width.

  2. Coherence-population-trapping transients induced by an ac magnetic field

    NASA Astrophysics Data System (ADS)

    Margalit, L.; Rosenbluh, M.; Wilson-Gordon, A. D.

    2012-06-01

    Coherent-population-trapping transients induced by an ac magnetic field are investigated theoretically for a realistic three-level Λ system in the D1 line of 87Rb. The contributions to the transient probe absorption from the various subsystems that compose the realistic atomic system are examined and the absorption of each Λ subsystem is compared to that of a simple Λ system. The population redistribution due to optical pumping is shown to be the dominant cause of the difference between the contributions of the various subsystems to the oscillatory character of the probe absorption. We also discuss the series of transients that reappear every half-cycle time of a modulated magnetic field when the system is in two-photon resonance, and we study the transient behavior as a function of the probe detuning. The effect of a buffer gas on the amplitude and shape of the transients is considered.

  3. Accelerated Detection of Viral Particles by Combining AC Electric Field Effects and Micro-Raman Spectroscopy

    PubMed Central

    Tomkins, Matthew Robert; Liao, David Shiqi; Docoslis, Aristides

    2015-01-01

    A detection method that combines electric field-assisted virus capture on antibody-decorated surfaces with the “fingerprinting” capabilities of micro-Raman spectroscopy is demonstrated for the case of M13 virus in water. The proof-of-principle surface mapping of model bioparticles (protein coated polystyrene spheres) captured by an AC electric field between planar microelectrodes is presented with a methodology for analyzing the resulting spectra by comparing relative peak intensities. The same principle is applied to dielectrophoretically captured M13 phage particles whose presence is indirectly confirmed with micro-Raman spectroscopy using NeutrAvidin-Cy3 as a labeling molecule. It is concluded that the combination of electrokinetically driven virus sampling and micro-Raman based signal transduction provides a promising approach for time-efficient and in situ detection of viruses. PMID:25580902

  4. Human aquaporin 4 gating dynamics in dc and ac electric fields: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Garate, J.-A.; English, Niall J.; MacElroy, J. M. D.

    2011-02-01

    Water self-diffusion within human aquaporin 4 has been studied using molecular dynamics (MD) simulations in the absence and presence of external ac and dc electric fields. The computed diffusive (pd) and osmotic (pf) permeabilities under zero-field conditions are (0.718 ± 0.24) × 10-14 cm3 s-1 and (2.94 ± 0.47) × 10-14 cm3 s-1, respectively; our pf agrees with the experimental value of (1.50 ± 0.6) × 10-14 cm3 s-1. A gating mechanism has been proposed in which side-chain dynamics of residue H201, located in the selectivity filter, play an essential role. In addition, for nonequilibrium MD in external fields, it was found that water dipole orientation within the constriction region of the channel is affected by electric fields (e-fields) and that this governs the permeability. It was also found that the rate of side-chain flipping motion of residue H201 is increased in the presence of e-fields, which influences water conductivity further.

  5. Design of a wide field of view infrared scene projector

    NASA Astrophysics Data System (ADS)

    Jiang, Zhenyu; Li, Lin; Huang, YiFan

    2008-03-01

    In order to make the projected scene cover the seeker's field-of-view promptly the conventional projection optical systems used for hardware-in-the-loop simulation test usually depend on the 5 axes flight-motion-simulator. Those flight-motion-simulator tables are controlled via servomechanisms. The servomechanism needs many axis position transducers and many electromechanical devices. The structure and controlling procedure of the system are complicated. It is hard to avoid the mechanical motion and controlling errors absolutely. The target image jitter will be induced by the vibration of mechanical platform, and the frequency response is limited by the structural performance. To overcome these defects a new infrared image simulating projection system for hardware-in-the-loop simulation test is presented in this paper. The system in this paper consists of multiple lenses joined side by side on a sphere surface. Each single lens uses one IR image generator or resistor array etc. Every IR image generator displays special IR image controlled by the scene simulation computer. The scene computer distributes to every IR image generator the needed image. So the scene detected by the missile seeker is integrated and uninterrupted. The entrance pupil of the seeker lies in the centre of the sphere. Almost semi-sphere range scene can be achieved by the projection system, and the total field of view can be extended by increasing the number of the lenses. However, the luminance uniformity in the field-of-view will be influenced by the joint between the lenses. The method of controlling the luminance uniformity of field-of-view is studied in this paper. The needed luminous exitance of each resist array is analyzed. The experiment shows that the new method is applicable for the hardware-in-the-loop simulation test.

  6. A Compact, Fast, Wide-Field Imaging Spectrometer System

    NASA Technical Reports Server (NTRS)

    Mouroulis, Pantazis; VanGorp, Byron E.; White, Victor E.; Mumolo, Jason M.; Hebert, Daniel; Feldman, Martin

    2011-01-01

    We present test results from a compact, fast (F/1.4) imaging spectrometer system with a 33 degree field of view, operating in the 450-1650 nm wavelength region with an extended response InGaAs detector array. The system incorporates a simple two-mirror telescope and a steeply concave bilinear groove diffraction grating made with gray scale x-ray lithography techniques. High degree of spectral and spatial uniformity (97%) is achieved.

  7. Engineering a highly segmented very wide-field spectrograph

    NASA Astrophysics Data System (ADS)

    Ragazzoni, R.; Fontana, A.; Maccagni, D.; Baruffolo, A.; Bianco, A. G.; diPaola, A.; Farinato, J.; Gentile, G.; Giallongo, E.; Pedichini, F.; Speziali, R.; Testa, V.

    2010-07-01

    The concept of segmenting the focal plane of an existing 8m class telescope in order to fill it with an array of several fast cameras has been developed further and in this work the status of an engineering program aimed to produce a design qualified for the construction, and to assess its cost estimates is presented. The original concept of just having simple cameras with all identical optical components other than a pupil plane corrector to remove the fixed aberrations at the off-axis field of a telescope has been extended to introduce a spectroscopic capability and to assess a trade-off between a very large number (of the order of thousand) of cameras with a small single Field of View with a smaller number of cameras able to compensate the aberration on a much larger Field of View with a combination of different optical elements and different ways to mount and align them. The scientific target of a few thousands multi-slit spectra over a Field of View of a few square degrees, combined with the ambition to mount this on an existing 8m class telescope makes the scientific rationale of such an instrument a very interesting one. In the paper we describe the different options for a possible optical design, the trade off between variations on the theme of the large segmentation and we describe briefly the way this kind of instrument can handle a multi-slit configuration. Finally, the feasibility of the components and a brief description of how the cost analysis is being performed are given. Perspectives on the construction of this spectrograph are given as well.

  8. Wide Field Imaging of the Hubble Deep Field-South Region III: Catalog

    NASA Technical Reports Server (NTRS)

    Palunas, Povilas; Collins, Nicholas R.; Gardner, Jonathan P.; Hill, Robert S.; Malumuth, Eliot M.; Rhodes, Jason; Teplitz, Harry I.; Woodgate, Bruce E.

    2002-01-01

    We present 1/2 square degree uBVRI imaging around the Hubble Deep Field - South. These data have been used in earlier papers to examine the QSO population and the evolution of the correlation function in the region around the HDF-S. The images were obtained with the Big Throughput Camera at CTIO in September 1998. The images reach 5 sigma limits of u approx. 24.4, B approx. 25.6, V approx. 25.3, R approx. 24.9 and I approx. 23.9. We present a catalog of approx. 22,000 galaxies. We also present number-magnitude counts and a comparison with other observations of the same field. The data presented here are available over the world wide web.

  9. Wide-field high-performance geosynchronous imaging

    NASA Astrophysics Data System (ADS)

    Wood, H. John; Jenstrom, Del; Wilson, Mark; Hinkal, Sanford; Kirchman, Frank

    1998-01-01

    The NASA Mission to Planet Earth (MTPE) Program and the National Oceanographic and Atmospheric Administration (NOAA) are sponsoring the Advanced Geosynchronous Studies (AGS) to develop technologies and system concepts for Earth observation from geosynchronous orbit. This series of studies is intended to benefit both MTPE science and the NOAA GOES Program. Within the AGS program, advanced imager trade studies have investigated two candidate concepts for near-term advanced geosynchronous imagers. One concept uses a scan mirror to direct the line of sight from a 3-axis stabilized platform. Another eliminates the need for a scan mirror by using an agile spacecraft bus to scan the entire instrument. The purpose of this paper is to discuss the optical design trades and system issues encountered in evaluating the two scanning approaches. The imager design started with a look at first principles: what is the most efficient way to image the Earth in those numerous spectral bands of interest to MTPE scientists and NOAA weather forecasters. Optical design trades included rotating filter wheels and dispersive grating instruments. The design converged on a bandpass filter instrument using four focal planes to cover the spectral range 0.45 to 13.0 micrometers. The first imager design uses a small agile spacecraft supporting an afocal optical telescope. Dichroic beamsplitters feed refractive objectives to four focal planes. The detectors are a series of long linear and rectangular arrays which are scanned in a raster fashion over the 17 degree Earth image. The use of the spacecraft attitude control system to raster the imager field-of-view (FOV) back and forth over the Earth eliminates the need for a scan mirror. However, the price paid is significant energy and time required to reverse the spacecraft slew motions at the end of each scan line. Hence, it is desired to minimize the number of scan lines needed to cover the full Earth disk. This desire, coupled with the ground

  10. Wide-field high-performance geosynchronous imaging

    SciTech Connect

    Wood, H. John; Jenstrom, Del; Wilson, Mark; Hinkal, Sanford; Kirchman, Frank

    1998-01-15

    The NASA Mission to Planet Earth (MTPE) Program and the National Oceanographic and Atmospheric Administration (NOAA) are sponsoring the Advanced Geosynchronous Studies (AGS) to develop technologies and system concepts for Earth observation from geosynchronous orbit. This series of studies is intended to benefit both MTPE science and the NOAA GOES Program. Within the AGS program, advanced imager trade studies have investigated two candidate concepts for near-term advanced geosynchronous imagers. One concept uses a scan mirror to direct the line of sight from a 3-axis stabilized platform. Another eliminates the need for a scan mirror by using an agile spacecraft bus to scan the entire instrument. The purpose of this paper is to discuss the optical design trades and system issues encountered in evaluating the two scanning approaches. The imager design started with a look at first principles: what is the most efficient way to image the Earth in those numerous spectral bands of interest to MTPE scientists and NOAA weather forecasters. Optical design trades included rotating filter wheels and dispersive grating instruments. The design converged on a bandpass filter instrument using four focal planes to cover the spectral range 0.45 to 13.0 micrometers. The first imager design uses a small agile spacecraft supporting an afocal optical telescope. Dichroic beamsplitters feed refractive objectives to four focal planes. The detectors are a series of long linear and rectangular arrays which are scanned in a raster fashion over the 17 degree Earth image. The use of the spacecraft attitude control system to raster the imager field-of-view (FOV) back and forth over the Earth eliminates the need for a scan mirror. However, the price paid is significant energy and time required to reverse the spacecraft slew motions at the end of each scan line. Hence, it is desired to minimize the number of scan lines needed to cover the full Earth disk. This desire, coupled with the ground

  11. Wide-field Raman imaging for bone detection in tissue.

    PubMed

    Papour, Asael; Kwak, Jin Hee; Taylor, Zach; Wu, Benjamin; Stafsudd, Oscar; Grundfest, Warren

    2015-10-01

    Inappropriate bone growth in soft tissue can occur after trauma to a limb and can cause a disruption to the healing process. This is known as Heterotopic Ossification (HO) in which regions in the tissue start to mineralize and form microscopic bone-like structures. These structures continue to calcify and develop into large, non-functional bony masses that cause pain, limit limb movement, and expose the tissue to reoccurring infections; in the case of open wounds this can lead to amputation as a result of a failed wound. Both Magnetic Resonance Imaging (MRI) and X-ray imaging have poor sensitivity and specificity for the detection of HO, thus delaying therapy and leading to poor patient outcomes. We present a low-power, fast (1 frame per second) optical Raman imaging system with a large field of view (1 cm(2)) that can differentiate bone tissue from soft tissue without spectroscopy, this in contrast to conventional Raman microscopy systems. This capability may allow for the development of instrumentation which permits bedside diagnosis of HO. PMID:26504639

  12. Mesoscopic turbulence and local order in Janus particles self-propelling under an ac electric field

    NASA Astrophysics Data System (ADS)

    Nishiguchi, Daiki; Sano, Masaki

    2015-11-01

    To elucidate mechanisms of mesoscopic turbulence exhibited by active particles, we experimentally study turbulent states of nonliving self-propelled particles. We realize an experimental system with dense suspensions of asymmetrical colloidal particles (Janus particles) self-propelling on a two-dimensional surface under an ac electric field. Velocity fields of the Janus particles in the crowded situation can be regarded as a sort of turbulence because it contains many vortices and their velocities change abruptly. Correlation functions of their velocity field reveal the coexistence of polar alignment and antiparallel alignment interactions, which is considered to trigger mesoscopic turbulence. Probability distributions of local order parameters for polar and nematic orders indicate the formation of local clusters with particles moving in the same direction. A broad peak in the energy spectrum of the velocity field appears at the spatial scales where the polar alignment and the cluster formation are observed. Energy is injected at the particle scale and conserved quantities such as energy could be cascading toward the larger clusters.

  13. Mesoscopic turbulence and local order in Janus particles self-propelling under an ac electric field.

    PubMed

    Nishiguchi, Daiki; Sano, Masaki

    2015-11-01

    To elucidate mechanisms of mesoscopic turbulence exhibited by active particles, we experimentally study turbulent states of nonliving self-propelled particles. We realize an experimental system with dense suspensions of asymmetrical colloidal particles (Janus particles) self-propelling on a two-dimensional surface under an ac electric field. Velocity fields of the Janus particles in the crowded situation can be regarded as a sort of turbulence because it contains many vortices and their velocities change abruptly. Correlation functions of their velocity field reveal the coexistence of polar alignment and antiparallel alignment interactions, which is considered to trigger mesoscopic turbulence. Probability distributions of local order parameters for polar and nematic orders indicate the formation of local clusters with particles moving in the same direction. A broad peak in the energy spectrum of the velocity field appears at the spatial scales where the polar alignment and the cluster formation are observed. Energy is injected at the particle scale and conserved quantities such as energy could be cascading toward the larger clusters. PMID:26651697

  14. Deformation and Interaction of Droplet Pairs in a Microchannel Under ac Electric Fields

    NASA Astrophysics Data System (ADS)

    Chen, Xiaodong; Song, Yongxin; Li, Dongqing; Hu, Guoqing

    2015-08-01

    The deformation and interaction of a droplet pair in an electric field determine the success of droplet coalescence. Electric intensity and initial droplet separation are crucial parameters in this process. In this work, a combined theoretical and numerical analysis is performed to study the electrohydrodynamics of confined droplet pairs in a rectangular microchannel under ac electric fields. We develop a theoretical model to predict the relationship between critical electric intensity and droplet separation. A geometrical model relating the initial droplet separation to the cone angle is also established to determine the critical separation for partial coalescence. These models are validated by comparisons with existing experimental observations. According to the initial separation and electric intensity, five regimes of droplet interactions are classified by direct numerical simulations, namely noncoalescence, coalescence, partial coalescence, ejection after coalescence, and ejection with partial coalescence. According to their controlling mechanisms, the five regimes are distinguished by three well-defined boundaries. The detailed dynamics of the partial coalescence phenomenon is resolved when the droplet separation exceeds the critical value. A dynamic liquid bridge between the droplets is sustained by the competition between surface tension and electric stress. The dynamics of ejected microjets at the exterior ends are also addressed to show their responses to the oscillating electric field. The full understanding of the droplet dynamics under electric fields can be used to predict the droplet fusion behaviors and thus to facilitate the design of droplet-based microfluidic devices.

  15. Standard and nonstandard nematic electrohydrodynamic convection in the presence of asymmetric ac electric fields

    NASA Astrophysics Data System (ADS)

    Low, Jonathan; Hogan, S. John

    2008-10-01

    In planar nematic electrohydrodynamic convection (EHC), a microscopic liquid crystal cell is driven by a homogeneous ac electric field, which, if strong enough, causes the fluid to destabilize into a regular pattern-forming state. We consider asymmetric electric fields E(t)=E(t+T)≠-E(t+T/2) , which leads to the possibility of three different types of instabilities at onset: conductive, dielectric, and subharmonic. The first two are already well known as they are easily produced when the system is driven by symmetric electric fields; the third can only occur when the electric field symmetry is broken. We present theoretical results on EHC using linear stability analysis and Floquet theory. We consider rigid and free boundary conditions, extending the model to two Fourier modes in the vertical plane, the inclusion of flexoelectricity, and using standard (nematic electric conductivity σa>0 and dielectric anisotorpy γa<0 ) and nonstandard (σa<0) material parameters. We make full use of a three-dimensional linear model where two mutually perpendicular planar wave numbers q and p can be varied. Our results show that there is a qualitative difference between the boundary conditions used, which is also dependent on how many vertical Fourier modes were used in the model. We have obtained threshold values favoring oblique rolls in subharmonic and dielectric regimes in parameter space. For the nonstandard EHC parameter values, both conduction and subharmonic regimes disappear and only the dielectric threshold exists.

  16. The effect of dissipation on the torque and force experienced by nanoparticles in an AC field

    NASA Astrophysics Data System (ADS)

    Claro, F.; Fuchs, R.; Robles, P.; Rojas, R.

    2015-09-01

    We discuss the force and torque acting on spherical particles in an ensemble in the presence of a uniform AC electric field. We show that for a torque causing particle rotation to appear the particle must be absorptive. Our proof includes all electromagnetic excitations, which in the case of two or more particles gives rise to one or more resonances in the spectrum of force and torque depending on interparticle distance. Several peaks are found in the force and torque between two spheres at small interparticle distances, which coalesce to just one as the separation grows beyond three particle radii. We also show that in the presence of dissipation the force on each particle is nonconservative and may not be derived from the classical interaction potential energy as has been done in the past.

  17. External dc bias field effects in the nonlinear ac stationary response of permanent dipoles in a uniaxial potential

    NASA Astrophysics Data System (ADS)

    Wei, Nijun; Coffey, William T.; Déjardin, Pirre-Michel; Kalmykov, Yuri P.

    External dc bias field effects on the nonlinear dielectric relaxation and dynamic Kerr effect of a system of permanent dipoles in a uniaxial mean field potential are studied via the rotational Brownian motion model. Postulated in terms of the infinite hierarchy of differential-recurrence equations for the statistical moments (the expectation value of the Legendre polynomials), the dielectric and Kerr effect ac stationary responses may be evaluated for arbitrary dc bias field strength via perturbation theory in the ac field. We have given two complementary approaches for treating the nonlinear effects. The first is based on perturbation theory allowing one to calculate the nonlinear ac stationary responses using powerful matrix methods. The second approach based on the accurate two-mode approximation [D.A. Garanin, Phys. Rev. E. 54, 3250 (1996)] effectively generalizes the existing results for dipolar systems in superimposed ac and dc fields to a mean field potential. The results apply both to nonlinear dielectric relaxation and dynamic Kerr effect of nematics and to magnetic birefringence relaxation of ferrofluids. Furthermore, the given methods of the solution of infinite hierarchies of multi-term recurrence relations are quite general and can be applied to analogous nonlinear response problems.

  18. Geometry of the Hubble Space Telescope Wide Field/Planetary Camera field

    NASA Technical Reports Server (NTRS)

    Gould, Andrew; Yanny, Brian

    1994-01-01

    We present a solution for the relative positions and orientations of the four charge coupled device (CCD) chips on the Hubble Space Telescope (HST) Planetary Camera (PC). An accurate solution is required when matching HST images with ground-based images or with one another. The solution is accurate to about 2/3 PC pixel or about .03 sec, a tenfold improvement over the best previous solution. The CCDs are rotated relative to one another by up to 1 deg. The solution is based on images taken between December 1990 and June 1992 and is stable over that entire period. We also present a solution for the relative positions and orientations of the four CCD chips on the HST Wide Field Camera (WFC). This solution is accurate to about 1/2 WFC pixel or about .05 sec.

  19. Effects of low-intensity AC and/or DC electromagnetic fields on cell attachment and induction of apoptosis

    SciTech Connect

    Blumenthal, N.C.; Ricci, J.; Breger, L.; Zychlinsky, A.; Solomon, H.; Chen, G.G.; Kuznetsov, D.; Dorfman, R.

    1997-05-01

    Rat tendon fibroblast (RTF) and rat bone marrow (RBM) osteoprogenitor cells were cultured and exposed to AC and/or DC magnetic fields in a triaxial Helmholtz coil in an incubator for up to 13 days. The AC fields were at 60 and 1,000 Hz and up to 0.25 mT peak to peak, and the DC fields were up to 0.25 mT. At various combinations of field strengths and frequencies, AC and/or DC fields resulted in extensive detachment of preattached cells and prevented the normal attachment of cells not previously attached to substrates. In addition, the fields resulted in altered cell morphologies. When RTF and RBM cells were removed from the fields after several days of exposure, they partially reattached and assumed more normal morphologies. An additional set of experiments described in the Appendix corroborates these findings and also shows that low-frequency EMF also initiates apoptosis, i.e., programmed cell death, at the onset of cell detachment. Taken together, these results suggest that the electromagnetic fields result in significant alterations in cell metabolism and cytoskeleton structure. Further work is required to determine the relative effect of the electric and magnetic fields on these phenomena. The research has implications for understanding the role of fields in affecting bone healing in fracture nonunions, in cell detachment in cancer metastasis, and in the effect of EMF on organisms generally.

  20. Edge pinch instability of liquid metal sheet in a transverse high-frequency ac magnetic field.

    PubMed

    Priede, Jānis; Etay, Jacqueline; Fautrelle, Yves

    2006-06-01

    We analyze the linear stability of the edge of a thin liquid metal layer subject to a transverse high-frequency ac magnetic field. The layer is treated as a perfectly conducting liquid sheet that allows us to solve the problem analytically for both a semi-infinite geometry with a straight edge and a thin disk of finite radius. It is shown that the long-wave perturbations of a straight edge are monotonically unstable when the wave number exceeds the critical value k(c) = F0/(gamma l0), which is determined by the linear density of the electromagnetic force F0 acting on the edge, the surface tension gamma, and the effective arclength of edge thickness l0. Perturbations with wavelength shorter than critical are stabilized by the surface tension, whereas the growth rate of long-wave perturbations reduces as similar to k for k --> 0. Thus, there is the fastest growing perturbation with the wave number k max = 2/3 k(c). When the layer is arranged vertically, long-wave perturbations are stabilized by the gravity, and the critical perturbation is characterized by the capillary wave number k(c) = square root of (g rho/gamma), where g is the acceleration due to gravity and rho is the density of metal. In this case, the critical linear density of electromagnetic force is F(0,c) = 2k(c)l0 gamma, which corresponds to the critical current amplitude I(0,c) = 4 square root of (pi k(c) l0L gamma/mu 0) when the magnetic field is generated by a straight wire at the distance L directly above the edge. By applying the general approach developed for the semi-infinite sheet, we find that a circular disk of radius R0 placed in a transverse uniform high-frequency ac magnetic field with the induction amplitude B0 becomes linearly unstable with respect to exponentially growing perturbation with the azimuthal wave number m = 2 when the magnetic Bond number exceeds Bm(c) = B(0)2 R(0)2 / (2 mu 0 l0 gamma) = 3 pi. For Bm > Bm(c), the wave number of the fastest growing perturbation is m(max) = [2

  1. A very wide field wavefront sensor for a very narrow field interferometer

    NASA Astrophysics Data System (ADS)

    Viotto, V.; Ragazzoni, R.; Arcidiacono, C.; Bergomi, M.; Brunelli, A.; Dima, M.; Farinato, J.; Gentile, G.; Magrin, D.; Cosentino, G.; Diolaiti, E.; Foppiani, I.; Lombini, M.; Schreiber, L.; Bertram, T.; Bizenberger, P.; De Bonis, F.; Gässler, W.; Herbst, T.; Kuerster, M.; Meschke, D.; Mohr, L.; Rohloff, R.-R.

    2010-07-01

    The LINC-NIRVANA wavefront sensors are in their AIT phase. The first Ground-layerWavefront Sensor (GWS) is shaping in the Adaptive Optics laboratory of the Astronomical Observatory of Padova, while both the Mid- High Wavefront Sensors (MHWSs) have been aligned and tested as stand-alone units in the Observatory of Bologna (MHWS#1 aligned to LINC-NIRVANA post focal relay optics). LINC-NIRVANA is a Fizeau infrared interferometer equipped with advanced, MultiConjugated Adaptive Optics (MCAO) for the Large Binocular Telescope. The aim of the instrument is to allow true interferometric imagery over a 10" square Field of View (FoV), getting the sensitivity of a 12m telescope and the spatial resolution of a 22.8m one. Thanks to the MCAO concept, LINC-NIRVANA will use up to 20 Natural Guide Stars (NGS) which are divided, according to Layer-Oriented Multiple Field of View technique, between the GWSs and the MHWSs. To find such a large number of references, the AO systems will use a wide FoV of 6' in diameter and the light coming from the references used by each WFS will optically sum on its CCD camera. The MHWSs will detect the deformations due to the high layers and will select up to 8 NGSs in the inner 2' FoV. The GWSs, instead, will reconstruct the deformations introduced by the lower atmosphere, which was found out to be the main source of seeing. Their peculiarity is the highest number of references (up to 12) ever used in a single instrument, selected in an annular 2'-6' FoV.

  2. In vitro cytotoxicity of Selol-loaded magnetic nanocapsules against neoplastic cell lines under AC magnetic field activation

    NASA Astrophysics Data System (ADS)

    Falqueiro, A. M.; Siqueira-Moura, M. P.; Jardim, D. R.; Primo, F. L.; Morais, P. C.; Mosiniewicz-Szablewska, E.; Suchocki, P.; Tedesco, A. C.

    2012-04-01

    The goals of this study are to evaluate invitro compatibility of magnetic nanomaterials and their therapeutic potential against cancer cells. Highly stable ionic magnetic fluid sample (maghemite, γ-Fe2O3) and Selol were incorporated into polymeric nanocapsules by nanoprecipitation method. The cytotoxic effect of Selol-loaded magnetic nanocapsules was assessed on murine melanoma (B16-F10) and oral squamous cell carcinoma (OSCC) cell lines following AC magnetic field application. The influence of different nanocapsules on cell viability was investigated by colorimetric MTT 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide assay. In the absence of AC magnetic field Selol-loaded magnetic nanocapsules, containing 100 µg/mL Selol plus 5 × 1012 particle/mL, showed antitumoral activity of about 50% on B16-F10 melanoma cells while OSCC carcinoma cells demonstrated drug resistance at all concentrations of Selol and magnetic fluid (range of 100-500 µg/mL Selol and 5 × 1012-2.5 × 1013 particle/mL). On the other hand, under AC applied fields (1 MHz and 40 Oe amplitude) B16-F10 cell viability was reduced down to 40.5% (±3.33) at the highest concentration of nanoencapsulated Selol. The major effect, however, was observed on OSCC cells since the cell viability drops down to about 33.3% (±0.38) under application of AC magnetic field. These findings clearly indicate that the Selol-loaded magnetic nanocapsules present different toxic effects on neoplastic cell lines. Further, the cytotoxic effect was maximized under AC magnetic field application on OSCC, which emphasizes the effectiveness of the magnetohyperthermia approach.

  3. Thermodynamics of the Mn12-ac molecule in a skew magnetic field at T \\gtrsim 21 K

    NASA Astrophysics Data System (ADS)

    Rojas, Onofre; Thomaz, M. T.; Corrêa Silva, E. V.; de Souza, S. M.

    2009-01-01

    We derive the high-temperature expansion of the Helmholtz free energy of the quantum and classical models for the Mn12-ac molecule in the presence of a skew magnetic field, including the transverse term in the Hamiltonians, for T \\gtrsim 21 K. In this region of temperature, we show that the transverse term can give a measurable contribution to the x component of the magnetization. We obtain the specific heat per site of a powder sample of Mn12-ac under a constant magnetic field. For strong skew magnetic fields (h/D>1), the specific heat differs up to 20% from its value of a crystal sample under purely longitudinal magnetic fields. Finally, we obtain that in the limit T \\rightarrow \\infty , the values of the classical and quantum specific heat differ; in particular, for \\vec {h}= \\vec 0 this difference is 0.96%.

  4. Study of the Dependence on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

    NASA Technical Reports Server (NTRS)

    Bandler, Simon

    2011-01-01

    At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in the AC bias configuration. For x-ray photons at 6keV the AC biased pixel shows a best energy resolution of 3.7eV, which is about a factor of 2 worse than the energy resolution observed in identical DC-biased pixels. To better understand the reasons of this discrepancy, we investigated the detector performance as a function of temperature, bias working point and applied magnetic field. A strong periodic dependence of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recent weak-link behaviour observed inTES microcalorimeters.

  5. Effects of AC/DC magnetic fields, frequency, and nanoparticle aspect ratio on cellular transfection of gene vectors

    NASA Astrophysics Data System (ADS)

    Ford, Kris; Mair, Lamar; Fisher, Mike; Rowshon Alam, Md.; Juliano, Rudolph; Superfine, Richard

    2008-10-01

    In order to make non-viral gene delivery a useful tool in the study and treatment of genetic disorders, it is imperative that these methodologies be further refined to yield optimal results. Transfection of magnetic nanoparticles and nanorods are used as non-viral gene vectors to transfect HeLa EGFP-654 cells that stably express a mutated enhanced green fluorescent protein (EGFP) gene. We deliver antisense oligonucleotides to these cells designed to correct the aberrant splicing caused by the mutation in the EGFP gene. We also transfect human bronchial endothelial cells and immortalized WI-38 lung cells with pEGFP-N1 vectors. To achieve this we bind the genes to magnetic nanoparticles and nanorods and introduce magnetic fields to effect transfection. We wish to examine the effects of magnetic fields on the transfection of these particles and the benefits of using alternating (AC) magnetic fields in improving transfection rates over direct (DC) magnetic fields. We specifically look at the frequency dependence of the AC field and particle aspect ratio as it pertains to influencing transfection rate. We posit that the increase in angular momentum brought about by the AC field and the high aspect ratio of the nanorod particles, is vital to generating the force needed to move the particle through the cell membrane.

  6. Oblique electromagnetic electron cyclotron waves for Kappa distribution with AC field in planetary magnetospheres

    NASA Astrophysics Data System (ADS)

    Pandey, R. S.; Kaur, Rajbir

    2015-08-01

    The dispersion relation for obliquely propagating relativistic electromagnetic electron cyclotron (EMEC) waves in collision-less magnetoplasma is obtained. Investigations for EMEC waves in magnetosphere of Jupiter, Saturn and Uranus have been done, in presence of perpendicular AC electric field for Kappa distribution function. The relativistic temporal growth rate is calculated using method of characteristic solution. Using the data provided by spacecrafts like Cassini, Voyager 1 and 2, while exploring the magnetosphere of Jupiter, Saturn and Uranus, is used to plot graphs showing growth rate being effected by various parameters. Comprehensive parametric analysis have been done at different radial distances of the planets. It is concluded that beside huge difference in magnetospheric configuration, temperature anisotropy remains the main source of energy in case of Jupiter and Uranus. While studying EMEC waves in magnetosphere of Saturn, it is inferred that growth rate attains maximum magnitude when angle of propagation increases. Also, the results and its interpretations explain how the growth of EMEC wave modifies in different magnetospheric conditions.

  7. Generation of liquid metal structures of high aspect ratio by application of an ac magnetic field

    NASA Astrophysics Data System (ADS)

    Andreev, Oleg; Pothérat, Alban; Thess, André

    2010-06-01

    We study how the shape of parts obtained through the LASER cladding process can be controlled by application of an ac magnetic field by means of two simple physical models: a numerical and an experimental one. More specifically, we show that straight metallic joints of high aspect ratio can be obtained by using inductors of triangular cross-section that concentrate electromagnetic forces at the bottom of the joint. The effect is first demonstrated on a numerical model for an infinitely long joint such as: we illustrate how the joint shape can be controlled by varying the inclination of the inductor and for a magnetic Bond number Bom=60 (which measures the ratio of electromagnetic to capillary forces), we obtain a joint of aspect ratio up to 7.2. We further find that inductor angles in the range 15°-25° lead to joint side faces that are close to vertical. These findings are then verified experimentally by placing a liquid metal drop in a purpose built inductor of triangular cross-section. We find a good agreement between the theoretical prediction of our two-dimensional model and the real three-dimensional drop. For the highest magnetic Bond number our generator could deliver, Bom=20.19, we achieved a drop aspect ratio of 2.73.

  8. Experience with wavefront sensor and deformable mirror interfaces for wide-field adaptive optics systems

    NASA Astrophysics Data System (ADS)

    Basden, A. G.; Atkinson, D.; Bharmal, N. A.; Bitenc, U.; Brangier, M.; Buey, T.; Butterley, T.; Cano, D.; Chemla, F.; Clark, P.; Cohen, M.; Conan, J.-M.; de Cos, F. J.; Dickson, C.; Dipper, N. A.; Dunlop, C. N.; Feautrier, P.; Fusco, T.; Gach, J. L.; Gendron, E.; Geng, D.; Goodsell, S. J.; Gratadour, D.; Greenaway, A. H.; Guesalaga, A.; Guzman, C. D.; Henry, D.; Holck, D.; Hubert, Z.; Huet, J. M.; Kellerer, A.; Kulcsar, C.; Laporte, P.; Le Roux, B.; Looker, N.; Longmore, A. J.; Marteaud, M.; Martin, O.; Meimon, S.; Morel, C.; Morris, T. J.; Myers, R. M.; Osborn, J.; Perret, D.; Petit, C.; Raynaud, H.; Reeves, A. P.; Rousset, G.; Sanchez Lasheras, F.; Sanchez Rodriguez, M.; Santos, J. D.; Sevin, A.; Sivo, G.; Stadler, E.; Stobie, B.; Talbot, G.; Todd, S.; Vidal, F.; Younger, E. J.

    2016-06-01

    Recent advances in adaptive optics (AO) have led to the implementation of wide field-of-view AO systems. A number of wide-field AO systems are also planned for the forthcoming Extremely Large Telescopes. Such systems have multiple wavefront sensors of different types, and usually multiple deformable mirrors (DMs). Here, we report on our experience integrating cameras and DMs with the real-time control systems of two wide-field AO systems. These are CANARY, which has been operating on-sky since 2010, and DRAGON, which is a laboratory AO real-time demonstrator instrument. We detail the issues and difficulties that arose, along with the solutions we developed. We also provide recommendations for consideration when developing future wide-field AO systems.

  9. Problems with twilight/supersky flat-field for wide-field robotic telescopes and the solution

    NASA Astrophysics Data System (ADS)

    Wei, Peng; Shang, Zhaohui; Ma, Bin; Zhao, Cheng; Hu, Yi; Liu, Qiang

    2014-08-01

    Twilight/night sky images are often used for flat-fielding CCD images, but the brightness gradient in twilight/ night sky causes problems of accurate flat-field correction in astronomical images for wide-field telescopes. Using data from the Antarctic Survey Telescope (AST3), we found that when the sky brightness gradient is minimum and stable, there is still a gradient of 1% across AST3's field-of-view of 4.3 square degrees. We tested various approaches to remove the varying gradients in individual flat-field images. Our final optimal method can reduce the spatially dependent errors caused by the gradient to the negligible level. We also suggest a guideline of flat-fielding using twilight/night sky images for wide-field robotic autonomous telescopes.

  10. Wide field/planetary camera optics study. [for the large space telescope

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Design feasibility of the baseline optical design concept was established for the wide field/planetary camera (WF/PC) and will be used with the space telescope (ST) to obtain high angular resolution astronomical information over a wide field. The design concept employs internal optics to relay the ST image to a CCD detector system. Optical design performance predictions, sensitivity and tolerance analyses, manufacturability of the optical components, and acceptance testing of the two mirror Cassegrain relays are discussed.

  11. ACS Data Handbook v.6.0

    NASA Astrophysics Data System (ADS)

    Gonzaga, S.; et al.

    2011-03-01

    ACS was designed to provide a deep, wide-field survey capability from the visible to near-IR using the Wide Field Camera (WFC), high resolution imaging from the near-UV to near-IR with the now-defunct High Resolution Camera (HRC), and solar-blind far-UV imaging using the Solar Blind Camera (SBC). The discovery efficiency of ACS's Wide Field Channel (i.e., the product of WFC's field of view and throughput) is 10 times greater than that of WFPC2. The failure of ACS's CCD electronics in January 2007 brought a temporary halt to CCD imaging until Servicing Mission 4 in May 2009, when WFC functionality was restored. Unfortunately, the high-resolution optical imaging capability of HRC was not recovered.

  12. The attenuation of the levitation force of HTS bulk exposed to AC magnetic field on the above NdFeB guideway

    NASA Astrophysics Data System (ADS)

    Liu, Minxian; Wang, Yan

    2012-01-01

    In the present High Temperature Superconducting (HTS) maglev vehicle system, the air gaps between the adjacent permanent magnets make the magnetic fields above the NdFeB guideway non-uniform. So it is required to study the characteristics of levitation force of the HTS bulk affected by the non-uniform applied magnetic fields along the moving direction. In this paper, we have studied the characteristics of the levitation force relaxation by an experiment in which AC magnetic field generated by an electromagnet is used to simulate the time-varying magnetic field caused by the inhomogeneity of the NdFeB guideway. From the experiment results, it is found that the levitation force is attenuated with the application of the AC field, and the attenuation is increased with the amplitude of the AC field, but the attenuation is almost independent of the frequency the AC magnetic field.

  13. The magnetisation profiles and ac magnetisation losses in a single layer YBCO thin film caused by travelling magnetic field waves

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Coombs, Timothy

    2015-05-01

    This paper studies the magnetisation and ac magnetisation losses caused by a travelling magnetic wave on a single-layer YBCO thin film. This work provides thorough investigations on how the critical magnetic field gradient has been changed by the application of a travelling wave. Several conditions were studied such as zero-field cooling (ZFC), field cooling (FC) and a delta-shaped trapped field. It was found that the travelling wave tends to attenuate the existing critical magnetic field gradients in all these conditions. This interesting magnetic behaviour can be well predicted by the finite element (FEM) software with the E-J power law and Maxwell’s equations. The numerical simulations show that the existing critical current density has been compromised after applying the travelling wave. The magnetisation profile caused by the travelling wave is very different from the standing wave, while the magnetisation based on the standing wave can be interpreted by the Bean model and constant current density assumption. Based on the numerical method, which has reliability that has been solidly proven in the study, we have extended the study to the ac magnetisation losses. Comparisons were made between the travelling wave and the standing wave for this specific YBCO sample. It was found that by applying the magnetic wave of the same amplitude, the ac magnetisation loss caused by the travelling wave is about 1/3 of that caused by the standing wave. These results are helpful in understanding the general magnetism problems and ac magnetisation loss in the travelling magnetic wave conditions such as inside a high temperature superconducting (HTS) rotating machine, etc.

  14. Deep, wide-field, global VLBI observations of the Hubble deep field north (HDF-N) and flanking fields (HFF)

    NASA Astrophysics Data System (ADS)

    Chi, S.; Barthel, P. D.; Garrett, M. A.

    2013-02-01

    Context. Dust is commonly present in weakly radio emitting star-forming galaxies and this dust may obscure the signatures of accreting black holes in these objects. Aims: We aim to uncover weak active galactic nuclei, AGN, in the faint radio source population by means of deep high-resolution radio observations. Methods: VLBI observations with a world-wide array at unparallelled sensitivity are carried out to assess the nature of the faint radio source population in the Hubble deep field north and its flanking fields. Results: Images of twelve compact, AGN-driven radio sources are presented. These represent roughly one quarter of the detectable faint radio source sample. Most, but not all of these low power AGN have X-ray detections. Conclusions: The majority of the faint radio source population must be star-forming galaxies. Faint AGN occur in a variety of (distant) host galaxies, and these are often accompanied by a dust-obscured starburst. Deep, high-resolution VLBI is a unique, powerful technique to assess the occurrence of faint AGN.

  15. A Fast-sampling, Planar Array for Measuring the AC Field of Fermilab Pulsed Extraction Magnets

    SciTech Connect

    DiMarco, E.Joseph; Johnstone, C.; Kiemschies, O.; Kotelnikov, S.K.; Lamm, M.J.; Makulski, A.; Nehring, R.; Orris, D.F.; Russell, A.D.; Tartaglia, Michael Albert; Velev, G.; /Fermilab

    2008-06-25

    A system employing a planar array of inductive pick-up coils has been developed for measurements of the rapidly changing dipole field in pulsed extraction magnets for the Fermilab MuCool project. The magnets are of C-type and deigned to support a peak field of 0.65 T during 8.33 millisecond half-sine pulse at a 15 Hz repetition rate. The coils of the measurement system are fabricated on a single, 97.5 mm wide, 2-layer circuit board. The array of coils is simultaneously sampled at data rates of up to 100 kHz with 10 kHz bandwidth using 24-bit ADC's. A detailed overview of the system and data analysis is presented, along with a characterization of results and system performance.

  16. Simultaneous ac and dc magnetic field measurements in residential areas: Implications for resonance theories of biological effects

    SciTech Connect

    Wong, P.S.; Sastre, A.

    1995-10-01

    The goal of this study was to obtain data that could be used to evaluate the applicability of ``resonance`` theories of biological effects in residential settings. The authors first describe a measurement system which allows the study of ac and dc magnetic fields simultaneously in space and in time. Sample measurements were taken near two power lines, two objects and in two residential homes. The results show that the earth`s (dc) magnetic field was unaffected near power lines. The compass orientation of the power line influenced the relative values of the ac components parallel and perpendicular to the dc field. The electric heating system greatly affected the ac field levels in the home, causing the levels to increase from less than 1 mG to a maximum of 7.5 mG during heating. The magnitudes of the dc field in the two homes varied from about 380 to 650 mG, with the larger variations near metallic or magnetic objects such as the refrigerator or a metallic air duct. The earth`s field was elevated above its natural level within a distance of 8 feet from a subcompact passenger car, e.g., the level changed from about 540 to 1,100 mG beside the headlight. A steel chair changed the earth`s field by up to 60 mG within a distance of one foot. These results suggest that some of the narrow ``resonances`` described in laboratory studies may be difficult to observe against the variations in do field amplitude and direction resulting from the presence of everyday metallic objects.

  17. Angular Dependence of Transport AC Losses in Superconducting Wire with Position-Dependent Critical Current Density in a DC Magnetic Field

    NASA Astrophysics Data System (ADS)

    Su, Xing-liang; Xiong, Li-ting; Gao, Yuan-wen; Zhou, You-he

    2013-07-01

    Transport AC losses play a very important role in high temperature superconductors (HTSs), which usually carry AC transport current under applied magnetic field in typical application-like conditions. In this paper, we propose the analytical formula for transport AC losses in HTS wire by considering critical current density of both inhomogeneous and anisotropic field dependent. The angular dependence of critical current density is described by effective mass theory, and the HTS wire has inhomogeneous distribution cross-section of critical current density. We calculate the angular dependence of normalized AC losses under different DC applied magnetic fields. The numerical results of this formula agree well with the experiment data and are better than the results of Norris formula. This analytical formula can explain the deviation of experimental transport current losses from the Norris formula and apply to calculate transport AC losses in realistic practical condition.

  18. A Wide-Field NV Diamond Magnetic Imager for Highly Parallel Detection of Rare Biological Targets

    NASA Astrophysics Data System (ADS)

    Glenn, David; Lee, Kyungheon; Lee, Hakho; Walsworth, Ronald

    2014-05-01

    We have developed a wide-field magnetic imaging device based on Nitrogen Vacancy centers in diamond, optimized for the detection of rare, immunomagnetically labeled biological targets such as circulating tumor cells. The new imager allows simultaneous magnetic imaging over a ~ 1 mm2 field of view, approximately two orders of magnitude larger than previous implementations. We describe experiments to detect cancer cells tagged with superparamagnetic nanoparticles, including validation studies for a cell detection assay and technical considerations associated magnetic imaging over very wide fields of view.

  19. Effect of electric field configuration on streamer and partial discharge phenomena in a hydrocarbon insulating liquid under AC stress

    NASA Astrophysics Data System (ADS)

    Liu, Z.; Liu, Q.; Wang, Z. D.

    2016-05-01

    This paper concerns pre-breakdown phenomena, including streamer characteristics from a fundamental perspective and partial discharge (PD) measurements from an industrial perspective, in a hydrocarbon insulating liquid. The aim was to investigate the possible changes of the liquid’s streamer and PD characteristics and their correlations when the uniformity of the AC electric field varies. In the experiments, a plane-to-plane electrode system incorporating a needle protrusion was used in addition to a needle-to-plane electrode system. When the applied electric field became more uniform, fewer radial branches occurred and streamer propagation towards the ground electrode was enhanced. The transition from streamer propagation dominated breakdown in divergent fields to streamer initiation dominated breakdown in uniform fields was evidenced. Relationships between streamer and PD characteristics were established, which were found to be electric field dependent. PD of the same apparent charge would indicate longer streamers if the electric field is more uniform.

  20. Scalable wide-field optical coherence tomography-based angiography for in vivo imaging applications

    PubMed Central

    Xu, Jingjiang; Wei, Wei; Song, Shaozhen; Qi, Xiaoli; Wang, Ruikang K.

    2016-01-01

    Recent advances in optical coherence tomography (OCT)-based angiography have demonstrated a variety of biomedical applications in the diagnosis and therapeutic monitoring of diseases with vascular involvement. While promising, its imaging field of view (FOV) is however still limited (typically less than 9 mm2), which somehow slows down its clinical acceptance. In this paper, we report a high-speed spectral-domain OCT operating at 1310 nm to enable wide FOV up to 750 mm2. Using optical microangiography (OMAG) algorithm, we are able to map vascular networks within living biological tissues. Thanks to 2,048 pixel-array line scan InGaAs camera operating at 147 kHz scan rate, the system delivers a ranging depth of ~7.5 mm and provides wide-field OCT-based angiography at a single data acquisition. We implement two imaging modes (i.e., wide-field mode and high-resolution mode) in the OCT system, which gives highly scalable FOV with flexible lateral resolution. We demonstrate scalable wide-field vascular imaging for multiple finger nail beds in human and whole brain in mice with skull left intact at a single 3D scan, promising new opportunities for wide-field OCT-based angiography for many clinical applications. PMID:27231630

  1. Decay Characteristics of Levitation Force of YBCO Bulk Exposed to AC Magnetic Field above NdFeB Guideway

    NASA Astrophysics Data System (ADS)

    Liu, Minxian; Lu, Yiyun; Wang, Suyu; Ma, Guangtong

    2011-04-01

    The superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the nonuniformity of the magnetic field along the movement direction above the NdFeB guideway is inevitable due to the assembly error and inhomogeneity of the material property of the NdFeB magnet. So it is required to study the characteristics of levitation force of the bulks affected by the non-uniform applied magnetic fields along the moving direction. In this paper, we will study the characteristics of the levitation force relaxation between the HTS bulk and the NdFeB guideway by an experiment in which AC external magnetic field generated by an electromagnet is used to simulate the time-varying external magnetic field caused by the inhomogeneity of the guideway. From the experimental results, it has found that the levitation force is decreasing with the application of the AC external magnetic field, and the decay increasing with the amplitude of the applied magnetic field and is almost independent of the frequency.

  2. Superconductor-Mediated Modification of Gravity? AC Motor Experiments with Bulk YBCO Disks in Rotating Magnetic Fields

    NASA Technical Reports Server (NTRS)

    Noever, David A.; Koczor, Ronald J.; Roberson, Rick

    1998-01-01

    We have previously reported results using a high precision gravimeter to probe local gravity changes in the neighborhood of large bulk-processed high-temperature superconductors. Podkietnov, et al (Podkietnov, E. and Nieminen, R. (1992) A Possibility of Gravitational Force Shielding by Bulk YBa2 Cu3 O7-x Superconductor, Physica C, C203:441-444.) have indicated that rotating AC fields play an essential role in their observed distortion of combined gravity and barometric pressure readings. We report experiments on large (15 cm diameter) bulk YBCO ceramic superconductors placed in the core of a three-phase, AC motor stator. The applied rotating field produces up to a 12,000 revolutions per minute magnetic field. The field intensity decays rapidly from the maximum at the outer diameter of the superconducting disk (less than 60 Gauss) to the center (less than 10 Gauss). This configuration was applied with and without a permanent DC magnetic field levitating the superconducting disk, with corresponding gravity readings indicating an apparent increase in observed gravity of less than 1 x 10(exp -6)/sq cm, measured above the superconductor. No effect of the rotating magnetic field or thermal environment on the gravimeter readings or on rotating the superconducting disk was noted within the high precision of the observation. Implications for propulsion initiatives and power storage flywheel technologies for high temperature superconductors will be discussed for various spacecraft and satellite applications.

  3. Direct design of two freeform optical surfaces for wide field of view line imaging applications

    NASA Astrophysics Data System (ADS)

    Nie, Yunfeng; Thienpont, Hugo; Duerr, Fabian

    2016-04-01

    In this paper, we propose a multi-fields direct design method aiming to calculate two freeform surfaces with an entrance pupil incorporated for wide field of view on-axis line imaging applications. Both infinite and finite conjugate objectives can be designed with this approach. Since a wide angle imaging system requires more than few discrete perfect imaging points, the multi-fields design approach is based on partial coupling of multiple fields, which guarantees a much more balanced imaging performance over the full field of view. The optical path lengths (OPLs) and image points of numerous off-axis fields are calculated during the procedure, thus very few initial parameters are needed. The procedure to calculate such a freeform lens is explained in detail. We have designed an exemplary monochromatic single lens to demonstrate the functionality of the design method. A rotationally symmetric counterpart following the same specifications is compared in terms of RMS spot radius to demonstrate the clear benefit that freeform lens brings to on-axis line imaging systems. In addition, a practical achromatic wide angle objective is designed by combining our multi-fields design method with classic optical design strategies, serving as a very good starting point for further optimization in a commercial optical design program. The results from the perspective of aberrations plots and MTF values show a very good and well balanced performance over the full field of view.

  4. Wide-Field Imaging Interferometry Spatial-Spectral Image Synthesis Algorithms

    NASA Technical Reports Server (NTRS)

    Lyon, Richard G.; Leisawitz, David T.; Rinehart, Stephen A.; Memarsadeghi, Nargess; Sinukoff, Evan J.

    2012-01-01

    Developed is an algorithmic approach for wide field of view interferometric spatial-spectral image synthesis. The data collected from the interferometer consists of a set of double-Fourier image data cubes, one cube per baseline. These cubes are each three-dimensional consisting of arrays of two-dimensional detector counts versus delay line position. For each baseline a moving delay line allows collection of a large set of interferograms over the 2D wide field detector grid; one sampled interferogram per detector pixel per baseline. This aggregate set of interferograms, is algorithmically processed to construct a single spatial-spectral cube with angular resolution approaching the ratio of the wavelength to longest baseline. The wide field imaging is accomplished by insuring that the range of motion of the delay line encompasses the zero optical path difference fringe for each detector pixel in the desired field-of-view. Each baseline cube is incoherent relative to all other baseline cubes and thus has only phase information relative to itself. This lost phase information is recovered by having point, or otherwise known, sources within the field-of-view. The reference source phase is known and utilized as a constraint to recover the coherent phase relation between the baseline cubes and is key to the image synthesis. Described will be the mathematical formalism, with phase referencing and results will be shown using data collected from NASA/GSFC Wide-Field Imaging Interferometry Testbed (WIIT).

  5. Depth-resolved incoherent and coherent wide-field high-content imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    So, Peter T.

    2016-03-01

    Recent advances in depth-resolved wide-field imaging technique has enabled many high throughput applications in biology and medicine. Depth resolved imaging of incoherent signals can be readily accomplished with structured light illumination or nonlinear temporal focusing. The integration of these high throughput systems with novel spectroscopic resolving elements further enable high-content information extraction. We will introduce a novel near common-path interferometer and demonstrate its uses in toxicology and cancer biology applications. The extension of incoherent depth-resolved wide-field imaging to coherent modality is non-trivial. Here, we will cover recent advances in wide-field 3D resolved mapping of refractive index, absorbance, and vibronic components in biological specimens.

  6. Role of peroxide in AC electrical field exposure effects on Friend murine erythroleukemia cells during dielectrophoretic manipulations

    PubMed Central

    Wang, Xujing; Yang, Jun; Gascoyne, Peter R.C.

    2009-01-01

    The effects of AC field exposure on the viability and proliferation of mammalian cells under conditions appropriate for their dielectrophoretic manipulation and sorting were investigated using DS19 murine erythroleukemia cells as a model system. The frequency range 100 Hz-10 MHz and medium conductivities of 10 mS/m, 30 mS/m and 56 mS/m were studied for fields generated by applying signals of up to 7V peak to peak (p-p) to a parallel electrode array having equal electrode widths and gaps of 100 μm. Between 1 kHz and 10 MHz, cell viability after up to 40 min of field exposure was found to be above 95% and cells were able to proliferate. However, cell growth lag phase was extended with decreasing field frequency and with increasing voltage, medium conductivity and exposure duration. Modified growth behavior was not passed on to the next cell passage, indicating that field exposure did not cause permanent alterations in cell proliferation characteristics. Cell membrane potentials induced by field exposure were calculated and shown to be well below values typically associated with cell damage. Furthermore, medium treated by field exposure and then added to untreated cells produced the same modifications of growth as exposing cells directly, and these modifications occurred only when the electrode polarization voltage exceeded a threshold of ~0.4 V p-p. These findings suggested that electrochemical products generated during field exposure were responsible for the changes in cell growth. Finally, it was found that hydrogen peroxide was produced when sugar-containing media were exposed to fields and that normal cell growth could be restored by addition of catalase to the medium, whether or not field exposure occurred in the presence of cells. These results show that AC fields typically used for dielectrophoretic manipulation and sorting of cells do not damage DS19 cells and that cell alterations arising from electrochemical effects can be completely mitigated. PMID

  7. Study of the Dependency on Magnetic Field and Bias Voltage of an AC-Biased TES Microcalorimeter

    NASA Technical Reports Server (NTRS)

    Gottardi, L.; Bruijn, M.; denHartog, R.; Hoevers, H.; deKorte, P.; vanderKuur, J.; Linderman, M.; Adams, J.; Bailey, C.; Bandler, S.; Chervenak, J.; Eckart, M.; Finkbeiner, F.; Kelley, R.; Kilbourne, C.; Porter, F.; Sadlier, J.; Smith, S.

    2012-01-01

    At SRON we are studying the performance of a Goddard Space Flight Center single pixel TES microcalorimeter operated in an AC bias configuration. For x-ray photons at 6 keV the pixel shows an x-ray energy resolution Delta E(sub FWHM) = 3.7 eV, which is about a factor 2 worse than the energy resolution observed in an identical DC-biased pixel. In order to better understand the reasons for this discrepancy we characterized the detector as a function of temperature, bias working point and applied perpendicular magnetic field. A strong periodic dependency of the detector noise on the TES AC bias voltage is measured. We discuss the results in the framework of the recently observed weak-link behaviour of a TES microcalorimeter.

  8. The Wide-Field Imaging Interferometry Testbed (WIIT): Recent Progress and Results

    NASA Technical Reports Server (NTRS)

    Rinehart, Stephen A.; Frey, Bradley J.; Leisawitz, David T.; Lyon, Richard G.; Maher, Stephen F.; Martino, Anthony J.

    2008-01-01

    Continued research with the Wide-Field Imaging Interferometry Testbed (WIIT) has achieved several important milestones. We have moved WIIT into the Advanced Interferometry and Metrology (AIM) Laboratory at Goddard, and have characterized the testbed in this well-controlled environment. The system is now completely automated and we are in the process of acquiring large data sets for analysis. In this paper, we discuss these new developments and outline our future research directions. The WIIT testbed, combined with new data analysis techniques and algorithms, provides a demonstration of the technique of wide-field interferometric imaging, a powerful tool for future space-borne interferometers.

  9. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy.

    PubMed

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-01-01

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10(-20) A m(2), respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution. PMID:26932357

  10. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy

    PubMed Central

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-01-01

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10−20 A m2, respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution. PMID:26932357

  11. Quantitatively probing the magnetic behavior of individual nanoparticles by an AC field-modulated magnetic force microscopy

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Lu, Wei; Song, Yiming; Wang, Yuxin; Chen, Aiying; Yan, Biao; Yoshimura, Satoru; Saito, Hitoshi

    2016-03-01

    Despite decades of advances in magnetic imaging, obtaining direct, quantitative information with nanometer scale spatial resolution remains an outstanding challenge. Current approaches, for example, Hall micromagnetometer and nitrogen-vacancy magnetometer, are limited by highly complex experimental apparatus and a dedicated sample preparation process. Here we present a new AC field-modulated magnetic force microscopy (MFM) and report the local and quantitative measurements of the magnetic information of individual magnetic nanoparticles (MNPs), which is one of the most iconic objects of nanomagnetism. This technique provides simultaneously a direct visualization of the magnetization process of the individual MNPs, with spatial resolution and magnetic sensitivity of about 4.8 nm and 1.85 × 10-20 A m2, respectively, enabling us to separately estimate the distributions of the dipolar fields and the local switching fields of individual MNPs. Moreover, we demonstrate that quantitative magnetization moment of individual MNPs can be routinely obtained using MFM signals. Therefore, it underscores the power of the AC field-modulated MFM for biological and biomedical applications of MNPs and opens up the possibility for directly and quantitatively probing the weak magnetic stray fields from nanoscale magnetic systems with superior spatial resolution.

  12. An EUV Wide-Field Imager and Spectrometer for the ISS

    NASA Technical Reports Server (NTRS)

    Golub, Leon; Savage, Sabrina

    2016-01-01

    The Coronal Spectrographic Imager in the EUV, COSIE, combines a wide-field solar coronal EUV imager (EUVC) and an on-disk EUV imaging spectrometer (EUVS). Located on the International Space Station (ISS), the goal of the mission is to enhance our understanding of the dynamics of the Transition Corona (the region in which the coronal magnetic field transitions from closed to open), and to provide improved detection and tracking of solar eruptive events for space weather research.

  13. Comparison of AC losses, magnetic field/current distributions and critical currents of superconducting circular pancake coils and infinitely long stacks using coated conductors

    NASA Astrophysics Data System (ADS)

    Yuan, Weijia; Campbell, A. M.; Hong, Z.; Ainslie, M. D.; Coombs, T. A.

    2010-08-01

    A model is presented for calculating the AC losses, magnetic field/current density distribution and critical currents of a circular superconducting pancake coil. The assumption is that the magnetic flux lines will lie parallel to the wide faces of tapes in the unpenetrated area of the coil. Instead of using an infinitely long stack to approximate the circular coil, this paper gives an exact circular coil model using elliptic integrals. A new efficient numerical method is introduced to yield more accurate and fast computation. The computation results are in good agreement with the assumptions. For a small value of the coil radius, there is an asymmetry along the coil radius direction. As the coil radius increases, this asymmetry will gradually decrease, and the AC losses and penetration depth will increase, but the critical current will decrease. We find that if the internal radius is equal to the winding thickness, the infinitely long stack approximation overestimates the loss by 10% and even if the internal radius is reduced to zero, the error is still only 60%. The infinitely long stack approximation is therefore adequate for most practical purposes. In addition, the comparison result shows that the infinitely long stack approximation saves computation time significantly.

  14. Optical system of large relative aperture and wide field using aspheric corrector for detecting

    NASA Astrophysics Data System (ADS)

    Ming, Ming; Wang, Jianli; Zhang, Jingxu

    2009-05-01

    The magnitude requirement of space target detecting determines that the image of detecting telescope should have several performances: small spots, small 80% encircled energy diameter and good MTF(Modulation transfer function). So the aperture and field of view of optical system have some demands accordingly. The larger aperture, the more energy that telescope collects and higher magnitude the telescope detects; the wider field of view, the more extensive range which the telescope searches. Now most of ground telescopes whose apertures are from 500mm to 1000mm is on-axis optical system, so wide field of view becomes the most importance problem. To obtain large relative aperture and wide field of view, the paper introduces a catadioptric telescope with small aperture aspheric refractive corrector, whose conic surface will be used to remove the aberrations due to large relative aperture and wide field of view. As to the optical system, there is only one aspheric refractive corrector, and it is relatively easy for manufacturing because of its concave figure and normal material. The paper gives the example, and optimizes this optical system with ZEMAX program. And then the paper provides a specific analysis program for testing the aspheric refractive corrector. The aperture of this optical system is 750mm, and its relative aperture is 0.82, and the field of view is 3.6° diameter(diagonal). Its structure is simple and the image quality is also very good.

  15. Adaptive optics scanning laser ophthalmoscope with integrated wide-field retinal imaging and tracking

    PubMed Central

    Ferguson, R. Daniel; Zhong, Zhangyi; Hammer, Daniel X.; Mujat, Mircea; Patel, Ankit H.; Deng, Cong; Zou, Weiyao; Burns, Stephen A.

    2010-01-01

    We have developed a new, unified implementation of the adaptive optics scanning laser ophthalmoscope (AOSLO) incorporating a wide-field line-scanning ophthalmoscope (LSO) and a closed-loop optical retinal tracker. AOSLO raster scans are deflected by the integrated tracking mirrors so that direct AOSLO stabilization is automatic during tracking. The wide-field imager and large-spherical-mirror optical interface design, as well as a large-stroke deformable mirror (DM), enable the AOSLO image field to be corrected at any retinal coordinates of interest in a field of >25 deg. AO performance was assessed by imaging individuals with a range of refractive errors. In most subjects, image contrast was measurable at spatial frequencies close to the diffraction limit. Closed-loop optical (hardware) tracking performance was assessed by comparing sequential image series with and without stabilization. Though usually better than 10 μm rms, or 0.03 deg, tracking does not yet stabilize to single cone precision but significantly improves average image quality and increases the number of frames that can be successfully aligned by software-based post-processing methods. The new optical interface allows the high-resolution imaging field to be placed anywhere within the wide field without requiring the subject to re-fixate, enabling easier retinal navigation and faster, more efficient AOSLO montage capture and stitching. PMID:21045887

  16. Resonant vibration of a droplet located on a superhydrophobic surface under the vertical and horizontal ac field

    NASA Astrophysics Data System (ADS)

    Higashiyama, Y.; Ohuchi, T.; Sugimoto, T.

    2015-10-01

    A water droplet under an ac electric field with resonant frequency changes drastically its shape repeating extension and shrinkage, alternatively. To develop an electrostatic mixing method of small amount of liquid, resonant vibrating motion of a water droplet was investigated. Both horizontal and vertical fields were applied to the droplet placed on a super-hydrophobic plate with a contact angle of 150 degrees. From the video images of the droplet, the degree of deformation of the droplet shape was evaluated by deformation rate. Under the two-directional electric field, the deformation ratio at shrinkage was increased significantly. The height of the droplet varies from 1.2 to 1.8 times larger than that of the original droplet during vibrating motion. Furthermore, the deformation rate at shrinkage varies with time periodically due to rotating motion of the droplet. The vertical electric field might be effective to cause the turbulent flow inside of the droplet.

  17. The status of NASA's wide-field meteor camera network and preliminary results

    NASA Astrophysics Data System (ADS)

    Blaauw, R.; Cooke, W.; Kingery, A.; Suggs, R.

    2014-04-01

    NASA's Meteoroid Environment Office (MEO) recently established two wide-field cameras to detect meteors in the millimeter-size-range. This paper outlines the concepts of the system, the hardware and software, and results of 3,440 orbits seen from December 13, 2012 until May 14, 2014.

  18. Interferometric Imaging with the 32 Element Murchison Wide-Field Array

    NASA Astrophysics Data System (ADS)

    Ord, S. M.; Mitchell, D. A.; Wayth, R. B.; Greenhill, L. J.; Bernardi, G.; Gleadow, S.; Edgar, R. G.; Clark, M. A.; Allen, G.; Arcus, W.; Benkevitch, L.; Bowman, J. D.; Briggs, F. H.; Bunton, J. D.; Burns, S.; Cappallo, R. J.; Coles, W. A.; Corey, B. E.; deSouza, L.; Doeleman, S. S.; Derome, M.; Deshpande, A.; Emrich, D.; Goeke, R.; Gopalakrishna, M. R.; Herne, D.; Hewitt, J. N.; Kamini, P. A.; Kaplan, D. L.; Kasper, J. C.; Kincaid, B. B.; Kocz, J.; Kowald, E.; Kratzenberg, E.; Kumar, D.; Lonsdale, C. J.; Lynch, M. J.; McWhirter, S. R.; Madhavi, S.; Matejek, M.; Morales, M. F.; Morgan, E.; Oberoi, D.; Pathikulangara, J.; Prabu, T.; Rogers, A. E. E.; Roshi, A.; Salah, J. E.; Schinkel, A.; Udaya Shankar, N.; Srivani, K. S.; Stevens, J.; Tingay, S. J.; Vaccarella, A.; Waterson, M.; Webster, R. L.; Whitney, A. R.; Williams, A.; Williams, C.

    2010-11-01

    The Murchison Wide-Field Array (MWA) is a low-frequency radio telescope, currently under construction, intended to search for the spectral signature of the epoch of reionization (EOR) and to probe the structure of the solar corona. Sited in western Australia, the full MWA will comprise 8192 dipoles grouped into 512 tiles and will be capable of imaging the sky south of 40° declination, from 80 MHz to 300 MHz with an instantaneous field of view that is tens of degrees wide and a resolution of a few arcminutes. A 32 station prototype of the MWA has been recently commissioned and a set of observations has been taken that exercise the whole acquisition and processing pipeline. We present Stokes I, Q, and U images from two ~4 hr integrations of a field 20° wide centered on Pictoris A. These images demonstrate the capacity and stability of a real-time calibration and imaging technique employing the weighted addition of warped snapshots to counter extreme wide-field imaging distortions.

  19. Estimating crop production in Iowa from Advanced Wide Field Sensor (AWiFS) data

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Indian National Remote Sensing Agency ResourceSat-1 Advanced Wide Field Sensor (AWiFS) data for the USA is being provided online by the USDA Foreign Agricultural Service (FAS) and Arctic Slope Regional Corporation – Management Services (ASRC-MS). Because of the frequent revisit time and pixel sizes...

  20. The Status of NASA's Wide-Field Meteor Camera Network and Preliminary Results

    NASA Technical Reports Server (NTRS)

    Blaauw, R.; Cooke, W.; Kingery, A.; Suggs, R.

    2014-01-01

    NASA's Meteoroid Environment Office (MEO) recently established two wide-field cameras to detect meteors in the millimeter-size-range. This paper outlines the concepts of the system, the hardware and software, and results of 3,440 orbits seen from December 13, 2012 until May 14, 2014.

  1. Application of the wide-field shadowgraph technique to rotor wake visualization

    NASA Technical Reports Server (NTRS)

    Norman, Thomas R.; Light, Jeffrey S.

    1989-01-01

    The wide field shadowgraph technique is reviewed along with its application to the visualization of rotor wakes. In particular, current experimental methods and data reduction requirements are discussed. Sample shadowgraphs are presented. These include shadowgraphs of model-scale helicopter main rotors and tilt rotors, and full scale tail rotors, both in hover and in forward flight.

  2. Wide-field three-dimensional optical imaging using temporal focusing for holographically trapped microparticles.

    PubMed

    Spesyvtsev, Roman; Rendall, Helen A; Dholakia, Kishan

    2015-11-01

    A contemporary challenge across the natural sciences is the simultaneous optical imaging or stimulation of small numbers of cells or colloidal particles organized into arbitrary geometries. We demonstrate the use of temporal focusing with holographic optical tweezers in order to achieve depth-resolved two-photon imaging of trapped objects arranged in arbitrary three-dimensional (3D) geometries using a single objective. Trapping allows for the independent position control of multiple objects by holographic beam shaping. Temporal focusing of ultrashort pulses provides the wide-field two-photon depth-selective activation of fluorescent samples. We demonstrate the wide-field depth-resolved illumination of both trapped fluorescent beads and trapped HL60 cells in suspension with full 3D positioning control. These approaches are compatible with implementation through scattering media and can be beneficial for emergent studies in colloidal science and particularly optogenetics, offering targeted photoactivation over a wide area with micrometer-precision depth control. PMID:26512465

  3. The Wide-Field Imaging Interferometry Testbed: Enabling Techniques for High Angular Resolution Astronomy

    NASA Technical Reports Server (NTRS)

    Rinehart, S. A.; Armstrong, T.; Frey, Bradley J.; Jung, J.; Kirk, J.; Leisawitz, David T.; Leviton, Douglas B.; Lyon, R.; Maher, Stephen; Martino, Anthony J.; Pauls, T.

    2007-01-01

    The Wide-Field Imaging Interferometry Testbed (WIIT) was designed to develop techniques for wide-field of view imaging interferometry, using "double-Fourier" methods. These techniques will be important for a wide range of future spacebased interferometry missions. We have provided simple demonstrations of the methodology already, and continuing development of the testbed will lead to higher data rates, improved data quality, and refined algorithms for image reconstruction. At present, the testbed effort includes five lines of development; automation of the testbed, operation in an improved environment, acquisition of large high-quality datasets, development of image reconstruction algorithms, and analytical modeling of the testbed. We discuss the progress made towards the first four of these goals; the analytical modeling is discussed in a separate paper within this conference.

  4. Image quality criteria for wide-field x-ray imaging applications

    NASA Astrophysics Data System (ADS)

    Thompson, Patrick L.; Harvey, James E.

    1999-10-01

    For staring, wide-field applications, such as a solar x-ray imager, the severe off-axis aberrations of the classical Wolter Type-I grazing incidence x-ray telescope design drastically limits the 'resolution' near the solar limb. A specification upon on-axis fractional encircled energy is thus not an appropriate image quality criterion for such wide-angle applications. A more meaningful image quality criterion would be a field-weighted-average measure of 'resolution.' Since surface scattering effects from residual optical fabrication errors are always substantial at these very short wavelengths, the field-weighted-average half- power radius is a far more appropriate measure of aerial resolution. If an ideal mosaic detector array is being used in the focal plane, the finite pixel size provides a practical limit to this system performance. Thus, the total number of aerial resolution elements enclosed by the operational field-of-view, expressed as a percentage of the n umber of ideal detector pixels, is a further improved image quality criterion. In this paper we describe the development of an image quality criterion for wide-field applications of grazing incidence x-ray telescopes which leads to a new class of grazing incidence designs described in a following companion paper.

  5. Design of four-mirror afocal principal system for wide field multichannel infrared imaging

    NASA Astrophysics Data System (ADS)

    Hu, Bin; Huang, Ying; Li, Yan

    2015-08-01

    The image space scanning system is widely used for multichannel infrared imaging to overcome the absence of large infrared focal plane array. The field of view of afocal system directly influences the time resolution of the image space scanning system. The field of view of afocal system is generally less than 7°. Therefore, it is significant to design larger field of view of afocal system for increasing time resolution. The method of four-mirror afocal system design based on primary aberration is explored. The structural parameters are calculated according to magnification and obscuration ratio of each mirror. The conic parameters are calculated according to primary aberration coefficients. The procedure for calculating initial structural parameters is programmed. Then a four-mirror afocal system is designed with an entrance pupil diameter of 200mm, a field of view of 20°×1°, the operating wave band of 3~12μm, compression ratio of 2.5 times and the distance of exit pupil of 620mm. The results indicate that the maximum root mean square (RMS) wavefront error is less than 0.042λ(λ=7.5μm), the maximum optical path difference(OPD) is less than λ/4(λ=3~12μm). It has high imaging quality and the modulation transfer function (MTF) is approached to the diffraction limit. The method of afocal system design can be widely used for wide field multichannel infrared imaging.

  6. Automated motion correction using parallel-strip registration for wide-field en face OCT angiogram

    PubMed Central

    Zang, Pengxiao; Liu, Gangjun; Zhang, Miao; Dongye, Changlei; Wang, Jie; Pechauer, Alex D.; Hwang, Thomas S.; Wilson, David J.; Huang, David; Li, Dengwang

    2016-01-01

    We propose an innovative registration method to correct motion artifacts for wide-field optical coherence tomography angiography (OCTA) acquired by ultrahigh-speed swept-source OCT (>200 kHz A-scan rate). Considering that the number of A-scans along the fast axis is much higher than the number of positions along slow axis in the wide-field OCTA scan, a non-orthogonal scheme is introduced. Two en face angiograms in the vertical priority (2 y-fast) are divided into microsaccade-free parallel strips. A gross registration based on large vessels and a fine registration based on small vessels are sequentially applied to register parallel strips into a composite image. This technique is extended to automatically montage individual registered, motion-free angiograms into an ultrawide-field view. PMID:27446709

  7. Prime focus wide-field corrector designs with lossless atmospheric dispersion correction

    SciTech Connect

    Saunders, Will; Gillingham, Peter; Smith, Greg; Kent, Steve; Doel, Peter

    2014-07-18

    Wide-Field Corrector designs are presented for the Blanco and Mayall telescopes, the CFHT and the AAT. The designs are Terezibh-style, with 5 or 6 lenses, and modest negative optical power. They have 2.2-3 degree fields of view, with curved and telecentric focal surfaces suitable for fiber spectroscopy. Some variants also allow wide-field imaging, by changing the last WFC element. Apart from the adaptation of the Terebizh design for spectroscopy, the key feature is a new concept for a 'Compensating Lateral Atmospheric Dispersion Corrector', with two of the lenses being movable laterally by small amounts. This provides excellent atmospheric dispersion correction, without any additional surfaces or absorption. A novel and simple mechanism for providing the required lens motions is proposed, which requires just 3 linear actuators for each of the two moving lenses.

  8. Automated motion correction using parallel-strip registration for wide-field en face OCT angiogram.

    PubMed

    Zang, Pengxiao; Liu, Gangjun; Zhang, Miao; Dongye, Changlei; Wang, Jie; Pechauer, Alex D; Hwang, Thomas S; Wilson, David J; Huang, David; Li, Dengwang; Jia, Yali

    2016-07-01

    We propose an innovative registration method to correct motion artifacts for wide-field optical coherence tomography angiography (OCTA) acquired by ultrahigh-speed swept-source OCT (>200 kHz A-scan rate). Considering that the number of A-scans along the fast axis is much higher than the number of positions along slow axis in the wide-field OCTA scan, a non-orthogonal scheme is introduced. Two en face angiograms in the vertical priority (2 y-fast) are divided into microsaccade-free parallel strips. A gross registration based on large vessels and a fine registration based on small vessels are sequentially applied to register parallel strips into a composite image. This technique is extended to automatically montage individual registered, motion-free angiograms into an ultrawide-field view. PMID:27446709

  9. Metrology systems for active alignment control of the Hobby-Eberly Telescope wide field corrector

    NASA Astrophysics Data System (ADS)

    Lee, Hanshin; Hill, Gary J.; Hart, Michael; Cornell, Mark E.; Savage, Richard; Vattiat, Brian; Perry, Dave; Moller, William M.; Rafferty, Tom; Taylor, Trey; Rafal, Marc D.

    2010-07-01

    The Hobby-Eberly Telescope (HET) Wide-Field Upgrade (WFU) will be equipped with new metrology systems to actively control the optical alignment of the new four-mirror Wide-Field Corrector (WFC) as it tracks sidereal motion with respect to the fixed primary mirror. These systems include a tip/tilt sensor (TTS), distance measuring interferometers (DMI), guide probes (GP), and wavefront sensors (WFS). While the TTS and DMIs are to monitor the mechanical alignment of the WFC, the WFSs and GPs will produce direct measurement of the optical alignment of the WFC with respect to the HET primary mirror. Together, these systems provide fully redundant alignment and pointing information for the telescope, thereby keeping the WFC in focus and suppressing alignment-driven field aberrations. We describe the current snapshot of these systems and discuss their roles, expected performance, and operation plans.

  10. Concerning the Development of the Wide-Field Optics for WFXT Including Methods of Optimizing X-Ray Optical Prescriptions for Wide-Field Applications

    NASA Technical Reports Server (NTRS)

    Weisskopf, M. C.; Elsner, R. F.; O'Dell, S. L.; Ramsey, B. D.

    2010-01-01

    We present a progress report on the various endeavors we are undertaking at MSFC in support of the Wide Field X-Ray Telescope development. In particular we discuss assembly and alignment techniques, in-situ polishing corrections, and the results of our efforts to optimize mirror prescriptions including polynomial coefficients, relative shell displacements, detector placements and tilts. This optimization does not require a blind search through the multi-dimensional parameter space. Under the assumption that the parameters are small enough so that second order expansions are valid, we show that the performance at the detector can be expressed as a quadratic function with numerical coefficients derived from a ray trace through the underlying Wolter I optic. The optimal values for the parameters are found by solving the linear system of equations creating by setting derivatives of this function with respect to each parameter to zero.

  11. Advanced wide-field broad-passband refracting field correctors for large telescopes

    NASA Technical Reports Server (NTRS)

    Epps, H. W.; Angel, J. R. P.; Anderson, E.

    1984-01-01

    Design objectives, constraints, and optical data are presented for specific corrector designs under consideration for several large telescope projects. These include a preliminary 30-arcmin prime focus (f/2.0) refracting field corrector system for the University of California Ten-Meter Telescope (UC TMT); a compact 40-arcmin internal Cassegrain (f/1.75 hyperbola to f/5.0) broad-passband (3300 A to 1.0 micron) corrector suitable for imaging and multi-object spectroscopy at the UC TMT; three 60-arcmin Cassegrain correctors for 300-inch f/1.8 and f/2.0 parabolic primary mirrors suitable for a Fifteen-Meter NNTT/MMT; and a 300-inch 40-arcmin external Cassegrain (f/1.0 parabola to f/4.0) broad-passband (3300 A to 1.0 micron) corrector with ADC.

  12. Field_ac: a research project on ocean modelling in coastal areas. The experience in the Catalan Sea.

    NASA Astrophysics Data System (ADS)

    Grifoll, Manel; Pallarès, Elena; Tolosana-Delgado, Raimon; Fernandez, Juan; Lopez, Jaime; Mosso, Cesar; Hermosilla, Fernando; Espino, Manuel; Sanchez-Arcilla, Agustín

    2013-04-01

    The EU founded Field_ac project has investigated during the last three years methods and strategies for improving operational services in coastal areas. The objective has been to generate added value for shelf and regional scale predictions from GMES Marine Core Services. In this sense the experience in the Catalan Sea site has allowed to combine high-resolution numerical modeling tools nested into regional GMES services, data from intensive field campaigns or local observational networks and remote sensing products. Multi-scale coupled models have been implemented to evaluate different temporal and spatial scales of the dominant physical processes related with waves, currents, continental/river discharges or sediment transport. In this sense the experience of the Field_ac project in the Catalan Sea has permit to "connect" GMES marine core service results to the coastal (local) anthropogenic forcing (e.g. causes of morphodynamic evolution and ecosystem degradation) and will support a knowledge-based assessment of decisions in the coastal zone. This will contribute to the implementation of EU directives (e.g., the Water Framework Directive for water quality at beaches near harbour entrances or the Risk or Flood Directives for waves and sea-level at beach/river-mouth scales).

  13. Dc to ac field conversion due to leaky-wave excitation in a plasma slab behind an ionization front

    NASA Astrophysics Data System (ADS)

    Kostin, V. A.; Vvedenskii, N. V.

    2015-03-01

    We present a way for generating coherent tunable electromagnetic radiation through dc to ac field conversion by an ionization front. The conversion is caused by the excitation of leaky waves behind the transversely limited ionization front propagating in a uniform electrostatic field. This differs significantly from the well-known dc-to-ac-radiation-converter models which consider Doppler-like frequency conversion by a transversely unlimited ionization front propagating in a spatially periodic electric field. We explore the dispersion properties and excitation of these leaky waves radiated through the transverse plasma boundary at the Cherenkov angle to the direction of propagation of a superluminal ionization front as dependent on the parameters of the plasma produced and on the speed of the ionization front. It is shown that not only the center frequency but also the duration and waveform of the generated pulse may significantly depend on the speed of the ionization front. The results indicate the possibility of using such converters based on planar photoconductive antennas to create sources of microwave and terahertz radiation with controllable waveforms that are transformed from video to radio pulse when the angle of incident ionizing radiation is tuned.

  14. An all-reflective wide-angle flat-field telescope for space

    NASA Technical Reports Server (NTRS)

    Hallam, K. L.; Howell, B. J.; Wilson, M. E.

    1984-01-01

    An all-reflective wide-angle flat-field telescope (WAFFT) designed and built at Goddard Space Flight Center demonstrates the markedly improved wide-angle imaging capability which can be achieved with a design based on a recently announced class of unobscured 3-mirror optical systems. Astronomy and earth observation missions in space dictate the necessity or preference for wide-angle all-reflective systems which can provide UV through IR wavelength coverage and tolerate the space environment. An initial prototype unit has been designed to meet imaging requirements suitable for monitoring the ultraviolet sky from space. The unobscured f/4, 36 mm efl system achieves a full 20 x 30 deg field of view with resolution over a flat focal surface that is well matched for use with advanced ultraviolet image array detectors. Aspects of the design and fabrication approach, which have especially important bearing on the system solution, are reviewed; and test results are compared with the analytic performance predictions. Other possible applications of the WAFFT class of imaging system are briefly discussed. The exceptional wide-angle, high quality resolution, and very wide spectral coverage of the WAFFT-type optical system could make it a very important tool for future space research.

  15. Direction detectable static magnetic field imaging by frequency-modulated magnetic force microscopy with an AC magnetic field driven soft magnetic tip

    NASA Astrophysics Data System (ADS)

    Saito, Hitoshi; Ito, Ryoichi; Egawa, Genta; Li, Zhenghua; Yoshimura, Satoru

    2011-04-01

    Direction detectable static magnetic field imaging, which directly distinguishes the up and down direction of static perpendicular magnetic field from a sample surface and the polarity of magnetic charges on the surface, was demonstrated for CoCrPt-SiO2 perpendicular magnetic recording media based on a frequency-modulated magnetic force microscopy (FM-MFM), which uses a frequency modulation of the cantilever oscillation induced by an alternating force from the tip-sample magnetic interaction. In this study, to generate the alternating force, we used a NiFe soft magnetic tip driven by the ac magnetic field of a soft ferrite core and imaged the direction and the amplitude of the static magnetic field from the recorded bits. This method enables measurement of the static magnetic field near a sample surface, which is masked by short range forces of the surface. The present method will be effective in analyzing the microscopic magnetic domain structure of hard magnetic samples.

  16. Design of a wide-field imaging optical system with super-resolution reconstruction

    NASA Astrophysics Data System (ADS)

    Shao, Xiaopeng; Xu, Jie; Wang, Jiaoyang; Chen, Xiaodong; Gong, Rui; Bi, Xiangli

    2015-05-01

    The need for a portable image acquiring system has become as strong as the extension of digital imaging technology, for this, a new mono-centric wide-field optical system is proposed. Recently, some high-resolution and wide-field imaging systems have been raised already, with which fairly clear and wide field of view (FOV) images could be easily obtained, however, their sizes are comparatively too large to be conveniently carried . With ZEMAX, a new optical design is emulated by scaling the structure of current wide-field optical systems and introducing the proposed lens-let arrays, the size of the whole system is comparatively smaller with the structure consisting of a two-glass mono-centric lens, lens-let array (the lenses in the array can be different), and a specific detector. Lens-let array is used to make the image plane from curve to almost flat. This hardware is small enough to apply to helmets and computers and the FOV of which is wide. Verified by a series of merit function, this optical design is found to have an acceptable imaging resolution and the computational imaging method is applied to this system to acquire a higher imaging resolution. From each lens-let a series of low resolution images are obtained and in this system a high-resolution image can be retrieved from multiple low-resolution images with super-resolution reconstruction method. Compared from the size and the imaging resolution, this new optical design is much smaller and has a higher imaging resolution.

  17. Single layer retarder with negative dispersion of birefringence and wide field-of-view.

    PubMed

    Hwang, Jiyong; Yang, Seungbin; Choi, Yu-Jin; Lee, Yumin; Jeong, Kwang-Un; Lee, Ji-Hoon

    2016-08-22

    A single layer retarder possessing negative dispersion (ND) of birefringence as well as wide field-of-view (FOV) was long-term objective in optical science. We synthesized new guest reactive monomers with x-shape and mixed them with the host smectic reactive mesogen. The host-guest molecules formed two dimensionally self-organized nanostructure and showed both the ND of birefringence and wide FOV properties. We simulated the antireflection property of a circular polarizer using the optical properties of the retarder. The average reflectance of the retarder was 0.52% which was much smaller than that of the commercial single layer ND retarder 1.83%. PMID:27557268

  18. Wide-field in vivo background free imaging by selective magnetic modulation of nanodiamond fluorescence

    PubMed Central

    Sarkar, Susanta K.; Bumb, Ambika; Wu, Xufeng; Sochacki, Kem A.; Kellman, Peter; Brechbiel, Martin W.; Neuman, Keir C.

    2014-01-01

    The sensitivity and resolution of fluorescence-based imaging in vivo is often limited by autofluorescence and other background noise. To overcome these limitations, we have developed a wide-field background-free imaging technique based on magnetic modulation of fluorescent nanodiamond emission. Fluorescent nanodiamonds are bright, photo-stable, biocompatible nanoparticles that are promising probes for a wide range of in vitro and in vivo imaging applications. Our readily applied background-free imaging technique improves the signal-to-background ratio for in vivo imaging up to 100-fold. This technique has the potential to significantly improve and extend fluorescent nanodiamond imaging capabilities on diverse fluorescence imaging platforms. PMID:24761300

  19. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches.

    PubMed

    Ma, Ying; Shaik, Mohammed A; Kim, Sharon H; Kozberg, Mariel G; Thibodeaux, David N; Zhao, Hanzhi T; Yu, Hang; Hillman, Elizabeth M C

    2016-10-01

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results.This article is part of the themed issue 'Interpreting BOLD: a dialogue between cognitive and cellular neuroscience'. PMID:27574312

  20. Wide-Field Fundus Autofluorescence for Retinitis Pigmentosa and Cone/Cone-Rod Dystrophy.

    PubMed

    Oishi, Akio; Oishi, Maho; Ogino, Ken; Morooka, Satoshi; Yoshimura, Nagahisa

    2016-01-01

    Retinitis pigmentosa and cone/cone-rod dystrophy are inherited retinal diseases characterized by the progressive loss of rod and/or cone photoreceptors. To evaluate the status of rod/cone photoreceptors and visual function, visual acuity and visual field tests, electroretinogram, and optical coherence tomography are typically used. In addition to these examinations, fundus autofluorescence (FAF) has recently garnered attention. FAF visualizes the intrinsic fluorescent material in the retina, which is mainly lipofuscin contained within the retinal pigment epithelium. While conventional devices offer limited viewing angles in FAF, the recently developed Optos machine enables recording of wide-field FAF. With wide-field analysis, an association between abnormal FAF areas and visual function was demonstrated in retinitis pigmentosa and cone-rod dystrophy. In addition, the presence of "patchy" hypoautofluorescent areas was found to be correlated with symptom duration. Although physicians should be cautious when interpreting wide-field FAF results because the peripheral parts of the image are magnified significantly, this examination method provides previously unavailable information. PMID:26427426

  1. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging

    PubMed Central

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.

    2015-01-01

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ±70∘ external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT. PMID:26740737

  2. Application of a wide-field phantom eye for optical coherence tomography and reflectance imaging

    NASA Astrophysics Data System (ADS)

    Corcoran, Anthony; Muyo, Gonzalo; van Hemert, Jano; Gorman, Alistair; Harvey, Andrew R.

    2015-12-01

    Optical coherence tomography (OCT) and reflectance imaging are used in clinical practice to measure the thickness and transverse dimensions of retinal features. The recent trend towards increasing the field of view (FOV) of these devices has led to an increasing significance of the optical aberrations of both the human eye and the device. We report the design, manufacture and application of the first phantom eye that reproduces the off-axis optical characteristics of the human eye, and allows the performance assessment of wide-field ophthalmic devices. We base our design and manufacture on the wide-field schematic eye, [Navarro, R. J. Opt. Soc. Am. A, 1985, 2.] as an accurate proxy to the human eye and enable assessment of ophthalmic imaging performance for a ? external FOV. We used multi-material 3D-printed retinal targets to assess imaging performance of the following ophthalmic instruments: the Optos 200Tx, Heidelberg Spectralis, Zeiss FF4 fundus camera and Optos OCT SLO and use the phantom to provide an insight into some of the challenges of wide-field OCT.

  3. Wide-field spatio-spectral interferometry for far-infrared space applications: A progress report

    NASA Astrophysics Data System (ADS)

    Leisawitz, David; Armstrong, J. T.; Bolcar, M. R.; Lyon, R.; Maher, S. F.; Memarsadeghi, N.; Rinehart, S.; Sinukoff, E.

    2014-01-01

    The NASA Astrophysics Roadmap Committee adopted the far-IR community’s vision and recommended far-IR interferometry as a needed capability in the 15 - 30 year time frame. The three major enabling technologies for such a mission are low-noise, high-speed detectors in small arrays; a demonstrated capability to cool optical system components to 4 K and focal planes to tens of mK with cryo-coolers; and the spatio-spectral interferometry (“double Fourier”) technique through which wide-field integral field spectroscopic data are derived from interferometric measurements. This paper reports on the current status of wide-field spatio-spectral interferometry and plans for maturation of the technique to space-flight readiness. Relatively simple spatial-spectral test patterns have been observed with the Wide-Field Imaging Interferometry Testbed at NASA’s Goddard Space Flight Center, and data cubes representing the observed scenes have been constructed based on the measured interferograms. A critical future milestone is the construction of an astronomically relevant, spatially and spectrally complex scene.

  4. A Panchromatic Catalog of Early-type Galaxies at Intermediate Redshift in the Hubble Space Telescope Wide Field Camera 3 Early Release Science Field

    NASA Astrophysics Data System (ADS)

    Rutkowski, M. J.; Cohen, S. H.; Kaviraj, S.; O'Connell, R. W.; Hathi, N. P.; Windhorst, R. A.; Ryan, R. E., Jr.; Crockett, R. M.; Yan, H.; Kimble, R. A.; Silk, J.; McCarthy, P. J.; Koekemoer, A.; Balick, B.; Bond, H. E.; Calzetti, D.; Disney, M. J.; Dopita, M. A.; Frogel, J. A.; Hall, D. N. B.; Holtzman, J. A.; Paresce, F.; Saha, A.; Trauger, J. T.; Walker, A. R.; Whitmore, B. C.; Young, E. T.

    2012-03-01

    In the first of a series of forthcoming publications, we present a panchromatic catalog of 102 visually selected early-type galaxies (ETGs) from observations in the Early Release Science (ERS) program with the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST) of the Great Observatories Origins Deep Survey-South (GOODS-S) field. Our ETGs span a large redshift range, 0.35 lsim z lsim 1.5, with each redshift spectroscopically confirmed by previous published surveys of the ERS field. We combine our measured WFC3 ERS and Advanced Camera for Surveys (ACS) GOODS-S photometry to gain continuous sensitivity from the rest-frame far-UV to near-IR emission for each ETG. The superior spatial resolution of the HST over this panchromatic baseline allows us to classify the ETGs by their small-scale internal structures, as well as their local environment. By fitting stellar population spectral templates to the broadband photometry of the ETGs, we determine that the average masses of the ETGs are comparable to the characteristic stellar mass of massive galaxies, 1011 < M *[M ⊙]<1012. By transforming the observed photometry into the Galaxy Evolution Explorer FUV and NUV, Johnson V, and Sloan Digital Sky Survey g' and r' bandpasses we identify a noteworthy diversity in the rest-frame UV-optical colors and find the mean rest-frame (FUV-V) = 3.5 and (NUV-V) = 3.3, with 1σ standard deviations sime1.0. The blue rest-frame UV-optical colors observed for most of the ETGs are evidence for star formation during the preceding gigayear, but no systems exhibit UV-optical photometry consistent with major recent (lsim50 Myr) starbursts. Future publications which address the diversity of stellar populations likely to be present in these ETGs, and the potential mechanisms by which recent star formation episodes are activated, are discussed.

  5. VizieR Online Data Catalog: MYStIX Wide-Field NIR data: crowded fields (King+, 2013)

    NASA Astrophysics Data System (ADS)

    King, R. R.; Naylor, T.; Broos, P. S.; Getman, K. V.; Feigelson, E. D.

    2014-01-01

    The data were obtained using WFCAM, the IR wide-field camera on UKIRT in Hawaii for 11 regions (DR 21, Eagle Nebula, Lagoon Nebula, M 17, NGC 1893, NGC 2264, NGC 2362, NGC 6334, NGC 6357, Rosette Nebula and the Trifid Nebula). Roughly half the fields were observed as part of the Galactic Plane Survey (GPS; Lucas et al. 2008, Cat. II/316) component of UKIDSS with the remainder being obtained in Director's Discretionary Time (DDT) using identical observing procedures. (1 data file).

  6. Distinctive receptive field and physiological properties of a wide-field amacrine cell in the macaque monkey retina

    PubMed Central

    Puller, Christian; Rieke, Fred; Neitz, Jay; Neitz, Maureen

    2015-01-01

    At early stages of visual processing, receptive fields are typically described as subtending local regions of space and thus performing computations on a narrow spatial scale. Nevertheless, stimulation well outside of the classical receptive field can exert clear and significant effects on visual processing. Given the distances over which they occur, the retinal mechanisms responsible for these long-range effects would certainly require signal propagation via active membrane properties. Here the physiology of a wide-field amacrine cell—the wiry cell—in macaque monkey retina is explored, revealing receptive fields that represent a striking departure from the classic structure. A single wiry cell integrates signals over wide regions of retina, 5–10 times larger than the classic receptive fields of most retinal ganglion cells. Wiry cells integrate signals over space much more effectively than predicted from passive signal propagation, and spatial integration is strongly attenuated during blockade of NMDA spikes but integration is insensitive to blockade of NaV channels with TTX. Thus these cells appear well suited for contributing to the long-range interactions of visual signals that characterize many aspects of visual perception. PMID:26133804

  7. SpIOMM and SITELLE: Wide-field Imaging FTS for the Study of Galaxy Evolution

    NASA Astrophysics Data System (ADS)

    Drissen, Laurent; Bernier, Anne-Pier; Robert, Carmelle; Robert

    2011-12-01

    SpIOMM, a wide-field Imaging Fourier Transform Spectrometer attached to the Mont Mégantic 1.6-m telescope, is capable of obtaining the visible spectrum of every source of light in a 12 arcminute field of view, with a spectral resolution ranging from R = 1 (wide-band image) to R = 25 000, resulting in 1.7 million spectra with a spatial resolution of one arcsecond. SITELLE will be a similar instrument attached to the Canada-France-Hawaii telescope, and will be in operation in early 2013. We present a short description of these instruments and illustrate their capabilities to study nearby galaxies with the results of a data cube of M51.

  8. A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

    NASA Technical Reports Server (NTRS)

    Toland, Ronald W.

    2003-01-01

    The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the performance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques.

  9. A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

    NASA Technical Reports Server (NTRS)

    Toland, Ronald W.

    2003-01-01

    The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the pefiormance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques. Finally, the use of the cathetometers on the flight optical bench and measurement results are given.

  10. Simultaneous multicolor imaging of wide-field epi-fluorescence microscopy with four-bucket detection

    PubMed Central

    Park, Kwan Seob; Kim, Dong Uk; Lee, Jooran; Kim, Geon Hee; Chang, Ki Soo

    2016-01-01

    We demonstrate simultaneous imaging of multiple fluorophores using wide-field epi-fluorescence microscopy with a monochrome camera. The intensities of the three lasers are modulated by a sinusoidal waveform in order to excite each fluorophore with the same modulation frequency and a different time-delay. Then, the modulated fluorescence emissions are simultaneously detected by a camera operating at four times the excitation frequency. We show that two different fluorescence beads having crosstalk can be clearly separated using digital processing based on the phase information. In addition, multiple organelles within multi-stained single cells are shown with the phase mapping method, demonstrating an improved dynamic range and contrast compared to the conventional fluorescence image. These findings suggest that wide-field epi-fluorescence microscopy with four-bucket detection could be utilized for high-contrast multicolor imaging applications such as drug delivery and fluorescence in situ hybridization. PMID:27375944

  11. Wide field-of-view soft X-ray imaging for solar wind-magnetosphere interactions

    NASA Astrophysics Data System (ADS)

    Walsh, B. M.; Collier, M. R.; Kuntz, K. D.; Porter, F. S.; Sibeck, D. G.; Snowden, S. L.; Carter, J. A.; Collado-Vega, Y.; Connor, H. K.; Cravens, T. E.; Read, A. M.; Sembay, S.; Thomas, N. E.

    2016-04-01

    Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

  12. System and methods for wide-field quantitative fluorescence imaging during neurosurgery.

    PubMed

    Valdes, Pablo A; Jacobs, Valerie L; Wilson, Brian C; Leblond, Frederic; Roberts, David W; Paulsen, Keith D

    2013-08-01

    We report an accurate, precise and sensitive method and system for quantitative fluorescence image-guided neurosurgery. With a low-noise, high-dynamic-range CMOS array, we perform rapid (integration times as low as 50 ms per wavelength) hyperspectral fluorescence and diffuse reflectance detection and apply a correction algorithm to compensate for the distorting effects of tissue absorption and scattering. Using this approach, we generated quantitative wide-field images of fluorescence in tissue-simulating phantoms for the fluorophore PpIX, having concentrations and optical absorption and scattering variations over clinically relevant ranges. The imaging system was tested in a rodent model of glioma, detecting quantitative levels down to 20 ng/ml. The resulting performance is a significant advance on existing wide-field quantitative imaging techniques, and provides performance comparable to a point-spectroscopy probe that has previously demonstrated significant potential for improved detection of malignant brain tumors during surgical resection. PMID:23903142

  13. Development of a wide-field spherical aberration corrector for the Hobby Eberly Telescope

    NASA Astrophysics Data System (ADS)

    Burge, James H.; Benjamin, S.; Dubin, M.; Manuel, A.; Novak, M.; Oh, C. J.; Valente, M.; Zhao, C.; Booth, J. A.; Good, J. M.; Hill, Gary J.; Lee, H.; MacQueen, P. J.; Rafal, M.; Savage, R.; Smith, M. P.; Vattiat, B.

    2010-07-01

    A 4-mirror prime focus corrector is under development to provide seeing-limited images for the 10-m aperture Hobby- Eberly Telescope (HET) over a 22 arcminute wide field of view. The HET uses an 11-m fixed elevation segmented spherical primary mirror, with pointing and tracking performed by moving the prime focus instrument package (PFIP) such that it rotates about the virtual center of curvature of the spherical primary mirror. The images created by the spherical primary mirror are aberrated with 13 arcmin diameter point spread function. The University of Arizona is developing the 4-mirror wide field corrector to compensate the aberrations from the primary mirror and present seeing limited imaged to the pickoffs for the fiber-fed spectrographs. The requirements for this system pose several challenges, including optical fabrication of the aspheric mirrors, system alignment, and operational mechanical stability.

  14. Wide-field optical coherence tomography based microangiography for retinal imaging

    NASA Astrophysics Data System (ADS)

    Zhang, Qinqin; Lee, Cecilia S.; Chao, Jennifer; Chen, Chieh-Li; Zhang, Thomas; Sharma, Utkarsh; Zhang, Anqi; Liu, Jin; Rezaei, Kasra; Pepple, Kathryn L.; Munsen, Richard; Kinyoun, James; Johnstone, Murray; van Gelder, Russell N.; Wang, Ruikang K.

    2016-02-01

    Optical coherence tomography angiography (OCTA) allows for the evaluation of functional retinal vascular networks without a need for contrast dyes. For sophisticated monitoring and diagnosis of retinal diseases, OCTA capable of providing wide-field and high definition images of retinal vasculature in a single image is desirable. We report OCTA with motion tracking through an auxiliary real-time line scan ophthalmoscope that is clinically feasible to image functional retinal vasculature in patients, with a coverage of more than 60 degrees of retina while still maintaining high definition and resolution. We demonstrate six illustrative cases with unprecedented details of vascular involvement in retinal diseases. In each case, OCTA yields images of the normal and diseased microvasculature at all levels of the retina, with higher resolution than observed with fluorescein angiography. Wide-field OCTA technology will be an important next step in augmenting the utility of OCT technology in clinical practice.

  15. Whole-cell-analysis of live cardiomyocytes using wide-field interferometric phase microscopy

    PubMed Central

    Shaked, Natan T.; Satterwhite, Lisa L.; Bursac, Nenad; Wax, Adam

    2010-01-01

    We apply wide-field interferometric microscopy techniques to acquire quantitative phase profiles of ventricular cardiomyocytes in vitro during their rapid contraction with high temporal and spatial resolution. The whole-cell phase profiles are analyzed to yield valuable quantitative parameters characterizing the cell dynamics, without the need to decouple thickness from refractive index differences. Our experimental results verify that these new parameters can be used with wide field interferometric microscopy to discriminate the modulation of cardiomyocyte contraction dynamics due to temperature variation. To demonstrate the necessity of the proposed numerical analysis for cardiomyocytes, we present confocal dual-fluorescence-channel microscopy results which show that the rapid motion of the cell organelles during contraction preclude assuming a homogenous refractive index over the entire cell contents, or using multiple-exposure or scanning microscopy. PMID:21258502

  16. Wide Field Infra-Red Survey Telescope (WFIRST) 2.4-Meter Mission Study

    NASA Technical Reports Server (NTRS)

    Content, D.; Aaron, K.; Alplanalp, L.; Anderson, K.; Capps, R.; Chang, Z.; Dooley, J.; Egerman, R.; Goullioud, R.; Klein, D.; Kruk, J.; Kuan, G.; Melton, M.; Ruffa, J.; Underhill, M.; Buren, D. Van

    2013-01-01

    The most recent study of the Wide Field Infrared Survey Telescope (WFIRST) mission is based on reuse of an existing 2.4m telescope. This study was commissioned by NASA to examine the potential science return and cost effectiveness of WFIRST by using this significantly larger aperture telescope. We review the science program envisioned by the WFIRST 2012-2013 Science Definition Team (SDT), an overview of the mission concept, and the telescope design and status. Comparisons against the previous 1.3m and reduced cost 1.1m WFIRST design concepts are discussed. A significant departure from past point designs is the option for serviceability and the geostationary orbit location which enables servicing and replacement instrument insertion later during mission life. Other papers at this conference provide more in depth discussion of the wide field instrument and the optional exoplanet imaging coronagraph instrument.

  17. Wide-field optical coherence tomography based microangiography for retinal imaging

    PubMed Central

    Zhang, Qinqin; Lee, Cecilia S.; Chao, Jennifer; Chen, Chieh-Li; Zhang, Thomas; Sharma, Utkarsh; Zhang, Anqi; Liu, Jin; Rezaei, Kasra; Pepple, Kathryn L.; Munsen, Richard; Kinyoun, James; Johnstone, Murray; Van Gelder, Russell N.; Wang, Ruikang K.

    2016-01-01

    Optical coherence tomography angiography (OCTA) allows for the evaluation of functional retinal vascular networks without a need for contrast dyes. For sophisticated monitoring and diagnosis of retinal diseases, OCTA capable of providing wide-field and high definition images of retinal vasculature in a single image is desirable. We report OCTA with motion tracking through an auxiliary real-time line scan ophthalmoscope that is clinically feasible to image functional retinal vasculature in patients, with a coverage of more than 60 degrees of retina while still maintaining high definition and resolution. We demonstrate six illustrative cases with unprecedented details of vascular involvement in retinal diseases. In each case, OCTA yields images of the normal and diseased microvasculature at all levels of the retina, with higher resolution than observed with fluorescein angiography. Wide-field OCTA technology will be an important next step in augmenting the utility of OCT technology in clinical practice. PMID:26912261

  18. Wide-field optical coherence tomography based microangiography for retinal imaging.

    PubMed

    Zhang, Qinqin; Lee, Cecilia S; Chao, Jennifer; Chen, Chieh-Li; Zhang, Thomas; Sharma, Utkarsh; Zhang, Anqi; Liu, Jin; Rezaei, Kasra; Pepple, Kathryn L; Munsen, Richard; Kinyoun, James; Johnstone, Murray; Van Gelder, Russell N; Wang, Ruikang K

    2016-01-01

    Optical coherence tomography angiography (OCTA) allows for the evaluation of functional retinal vascular networks without a need for contrast dyes. For sophisticated monitoring and diagnosis of retinal diseases, OCTA capable of providing wide-field and high definition images of retinal vasculature in a single image is desirable. We report OCTA with motion tracking through an auxiliary real-time line scan ophthalmoscope that is clinically feasible to image functional retinal vasculature in patients, with a coverage of more than 60 degrees of retina while still maintaining high definition and resolution. We demonstrate six illustrative cases with unprecedented details of vascular involvement in retinal diseases. In each case, OCTA yields images of the normal and diseased microvasculature at all levels of the retina, with higher resolution than observed with fluorescein angiography. Wide-field OCTA technology will be an important next step in augmenting the utility of OCT technology in clinical practice. PMID:26912261

  19. Wide-field fluorescence molecular tomography with compressive sensing based preconditioning

    PubMed Central

    Yao, Ruoyang; Pian, Qi; Intes, Xavier

    2015-01-01

    Wide-field optical tomography based on structured light illumination and detection strategies enables efficient tomographic imaging of large tissues at very fast acquisition speeds. However, the optical inverse problem based on such instrumental approach is still ill-conditioned. Herein, we investigate the benefit of employing compressive sensing-based preconditioning to wide-field structured illumination and detection approaches. We assess the performances of Fluorescence Molecular Tomography (FMT) when using such preconditioning methods both in silico and with experimental data. Additionally, we demonstrate that such methodology could be used to select the subset of patterns that provides optimal reconstruction performances. Lastly, we compare preconditioning data collected using a normal base that offers good experimental SNR against that directly acquired with optimal designed base. An experimental phantom study is provided to validate the proposed technique. PMID:26713202

  20. Simultaneous multicolor imaging of wide-field epi-fluorescence microscopy with four-bucket detection.

    PubMed

    Park, Kwan Seob; Kim, Dong Uk; Lee, Jooran; Kim, Geon Hee; Chang, Ki Soo

    2016-06-01

    We demonstrate simultaneous imaging of multiple fluorophores using wide-field epi-fluorescence microscopy with a monochrome camera. The intensities of the three lasers are modulated by a sinusoidal waveform in order to excite each fluorophore with the same modulation frequency and a different time-delay. Then, the modulated fluorescence emissions are simultaneously detected by a camera operating at four times the excitation frequency. We show that two different fluorescence beads having crosstalk can be clearly separated using digital processing based on the phase information. In addition, multiple organelles within multi-stained single cells are shown with the phase mapping method, demonstrating an improved dynamic range and contrast compared to the conventional fluorescence image. These findings suggest that wide-field epi-fluorescence microscopy with four-bucket detection could be utilized for high-contrast multicolor imaging applications such as drug delivery and fluorescence in situ hybridization. PMID:27375944

  1. Wide-field Monitoring of the Galactic Plane in the K- and the H-band

    NASA Astrophysics Data System (ADS)

    Yanagisawa, K.; Nakada, Y.; Izumiura, H.; Watanabe, E.; Shimizu, Y.; Okada, N.; Okita, K.; Norimoto, K.; Okata, T.; Koyano, H.; Yoshida, M.

    The Okayama Astrophysical Observatory of NAOJ started the monitoring program of mass-losing AGB stars using an imaging camera named Okayama Astrophysical Observatory Wide Field Camera. The fast optics yields a field of view of 1¡ß1 deg2 and the pixel resolution of 2 arcsec at the focus of the 91-cm telescope. A HAWAII2 array will be installed inside the camera reaching the limiting magnitude of K=13 with a 45-s exposure. In 2003 the monitoring will start covering the Galactic plane from l=0 to 270 deg every three weeks.

  2. Wide-field prime focus corrector for the Anglo-Australian telescope.

    PubMed

    Jones, D J

    1994-11-01

    A wide-field (2°) prime focus corrector has been designed and built for the Anglo-Australian Telescope. The corrector incorporates an atmospheric dispersion compensator for the spectral range 365-1014 nm. A four-element lens system is the basis of the corrector, and it provides a satisfactory state of correction over a full field of 2°. The design of the lens system is described. The choice of layout is related directly to the intrinsic properties of each component. PMID:20941295

  3. Scanner-Free and Wide-Field Endoscopic Imaging by Using a Single Multimode Optical Fiber

    NASA Astrophysics Data System (ADS)

    Choi, Youngwoon; Yoon, Changhyeong; Kim, Moonseok; Yang, Taeseok Daniel; Fang-Yen, Christopher; Dasari, Ramachandra R.; Lee, Kyoung Jin; Choi, Wonshik

    2012-11-01

    A single multimode fiber is considered an ideal optical element for endoscopic imaging due to the possibility of direct image transmission via multiple spatial modes. However, the wave distortion induced by the mode dispersion has been a fundamental limitation. In this Letter, we propose a method for eliminating the effect of mode dispersion and therefore realize wide-field endoscopic imaging by using only a single multimode fiber with no scanner attached to the fiber. Our method will potentially revolutionize endoscopy in various fields encompassing medicine and industry.

  4. Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy

    PubMed Central

    Greenbaum, Alon; Luo, Wei; Su, Ting-Wei; Göröcs, Zoltán; Xue, Liang; Isikman, Serhan O; Coskun, Ahmet F; Mudanyali, Onur; Ozcan, Aydogan

    2012-01-01

    We discuss unique features of lens-free computational imaging tools and report some of their emerging results for wide-field on-chip microscopy, such as the achievement of a numerical aperture (NA) of ~0.8–0.9 across a field of view (FOV) of more than 20 mm2 or an NA of ~0.1 across a FOV of ~18 cm2, which corresponds to an image with more than 1.5 gigapixels. We also discuss the current challenges that these computational on-chip microscopes face, shedding light on their future directions and applications. PMID:22936170

  5. Wide field-of-view lens-free fluorescent imaging on a chip

    PubMed Central

    Coskun, Ahmet F.; Su, Ting-Wei

    2010-01-01

    We demonstrate an on-chip fluorescent detection platform that can simultaneously image fluorescent micro-objects or labeled cells over an ultra-large field-of-view of 2.5 cm × 3.5 cm without the use of any lenses, thin-film filters and mechanical scanners. Such a wide field-of-view lensless fluorescent imaging modality, despite its limited resolution, might be very important for high-throughput screening applications as well as for detection and counting of rare cells within large-area microfluidic devices. PMID:20379564

  6. An optical design for a wide-field optical spectrograph for TMT

    NASA Astrophysics Data System (ADS)

    Bernstein, Rebecca A.; Bigelow, Bruce C.

    2008-07-01

    We describe a preliminary optical design for a multi-object, wide-field, optical echellette spectrograph that is intended to serve a broad range of science. It will produce low-resolution, single-order spectra for survey-mode programs targeting as many objects as possible and also moderate-resolution, multiple-order spectra for a reduced number of targets. The design uses all refracting optics. The first optical element of the spectrograph is a wide-field corrector for the telescope that causes the chief rays to be perpendicular to the focal plane. The collimator, which has been designed on-axis, can then be duplicated to target multiple, off-axis fields in a multiple-barrel configuration. The collimator optics include an achromatic field lens group that forms a sharp pupil over the full optical band-pass (320-1000 nm), followed by a dichroic which splits the beam into a red and a blue channel. All remaining optical elements of the collimator, the gratings, the cameras, and the detectors are then optimized for red or blue wavelengths. Both red and blue channels of each beam of the spectrograph use reflection gratings to produce either a single-order spectrum at resolutions around R=λ/Δλ=1000 or a five-order, R>5000 echellette spectrum with prism cross-dispersion. Both modes can target objects anywhere in the collimated field of view. A direct imaging mode will also be provided.

  7. Electrowetting liquid lens array on curved substrates for wide field of view image sensor

    NASA Astrophysics Data System (ADS)

    Bang, Yousung; Lee, Muyoung; Won, Yong Hyub

    2016-03-01

    In this research, electrowetting liquid lens array on curved substrates is developed for wide field of view image sensor. In the conventional image sensing system, this lens array is usually in the form of solid state. However, in this state, the lens array which is similar to insect-like compound eyes in nature has several limitations such as degradation of image quality and narrow field of view because it cannot adjust focal length of lens. For implementation of the more enhanced system, the curved array of lenses based on electrowetting effect is developed in this paper, which can adjust focal length of lens. The fabrication of curved lens array is conducted upon the several steps, including chamber fabrication, electrode & dielectric layer deposition, liquid injection, and encapsulation. As constituent materials, IZO coated convex glass, UV epoxy (NOA 68), DI water, and dodecane are used. The number of lenses on the fabricated panel is 23 by 23 and each lens has 1mm aperture with 1.6mm pitch between adjacent lenses. When the voltage is applied on the device, it is observed that each lens is changed from concave state to convex state. From the unique optical characteristics of curved array of liquid lenses such as controllable focal length and wide field of view, we can expect that it has potential applications in various fields such as medical diagnostics, surveillance systems, and light field photography.

  8. Inductive heat property of Fe3O4/polymer composite nanoparticles in an ac magnetic field for localized hyperthermia.

    PubMed

    Zhao, Dong-Lin; Zhang, Hai-Long; Zeng, Xian-Wei; Xia, Qi-Sheng; Tang, Jin-Tian

    2006-12-01

    The magnetite (Fe(3)O(4)) nanoparticles were prepared by coprecipitation of Fe(3+) and Fe(2+) with an aqueous NaOH solution. The Fe(3)O(4)/polyaniline (PANI) magnetic composite nanoparticles with a core-shell structure with a diameter of 30-50 nm were prepared via an in situ polymerization of aniline in an aqueous solution containing the Fe(3)O(4) magnetic fluid. The inductive heat property of Fe(3)O(4)/PANI composite nanoparticles in an alternating current (ac) magnetic field was investigated. The potential of Fe(3)O(4)/PANI nanoparticles was evaluated for localized hyperthermia treatment of cancers. The saturation magnetization, M(s), and coercivity, H(c), are 50.05 emu g(-1) and 137 Oe for Fe(3)O(4) nanoparticles and 26.34 emu g(-1) and 0 Oe for Fe(3)O(4)/PANI composite nanoparticles, respectively. Exposed in the ac magnetic field for 29 min, the temperatures of physiological saline suspensions containing Fe(3)O(4) nanoparticles or Fe(3)O(4)/PANI composite nanoparticles are 63.6 degrees C and 52.4 degrees C, respectively. The Fe(3)O(4)/PANI composite nanoparticles would be useful as good thermoseeds for localized hyperthermia treatment of cancers. PMID:18458406

  9. Applied AC and DC magnetic fields cause alterations in the mitotic cycle of early sea urchin embryos

    SciTech Connect

    Levin, M.; Ernst, S.G.

    1995-09-01

    This study demonstrates that exposure to 60 Hz magnetic fields (3.4--8.8 mt) and magnetic fields over the range DC-600 kHz (2.5--6.5 mT) can alter the early embryonic development of sea urchin embryos by inducing alterations in the timing of the cell cycle. Batches of fertilized eggs were exposed to the fields produced by a coil system. Samples of the continuous cultures were taken and scored for cell division. The times of both the first and second cell divisions were advanced by ELF AC fields and by static fields. The magnitude of the 60 Hz effect appears proportional to the field strength over the range tested. the relationship to field frequency was nonlinear and complex. For certain frequencies above the ELF range, the exposure resulted in a delay of the onset of mitosis. The advance of mitosis was also dependent on the duration of exposure and on the timing of exposure relative to fertilization.

  10. Hubble Space Telescope: Wide field and planetary camera instrument handbook. Version 2.1

    NASA Technical Reports Server (NTRS)

    Griffiths, Richard (Editor)

    1990-01-01

    An overview is presented of the development and construction of the Wide Field and Planetary Camera (WF/PC). The WF/PC is a duel two dimensional spectrophotometer with rudimentary polarimetric and transmission grating capabilities. The instrument operates from 1150 to 11000 A with a resolution of 0.1 arcsec per pixel or 0.043 arcsec per pixel. Data products and standard calibration methods are briefly summarized.

  11. High-resolution wide-field Raman imaging through a fiber bundle

    NASA Astrophysics Data System (ADS)

    Doronina-Amitonova, Lyubov V.; Fedotov, Il'ya V.; Fedotov, Andrey B.; Zheltikov, Aleksei M.

    2013-04-01

    Wide-field Raman imaging with a spatial resolution of a few micrometers is demonstrated using bundles of thousands of hexagonally packed optical fibers. Raman images are synthesized pixel by pixel, by sequentially coupling the laser pump into individual fibers of the bundle with a galvanometric scanner and collecting the Raman response from the laser-excited region of the sample within the entire aperture of the distal end of the same fiber bundle.

  12. A description of a wide beam saddle field ion source used for nuclear target applications

    SciTech Connect

    Greene, J.P.; Schiel, S.L.; Thomas, G.E.

    1997-07-01

    A description is given of a new, wide beam saddle field sputter source used for the preparation of targets applied in nuclear physics experiments. The ion source characteristics are presented and compared with published results obtained with other sources. Deposition rates acquired utilizing this source are given for a variety of target materials encountered in nuclear target production. New applications involving target thinning and ion milling are discussed.

  13. Sensors for the Hubble Space Telescope wide field and planetary cameras (1 and 2)

    NASA Technical Reports Server (NTRS)

    Trauger, John T.

    1990-01-01

    The technology of the wide field planetary camera (WFPC-2) CCD technology is examined with reference to the WFPC-1 experience. Strategies are presented for elimination of quantum efficiency (QE) hysteresis and implementation of maintenance-free QE stability, improved far-UV performance, on-orbit photometric calibrations, refinements in CCD electronics, and anticipated CCD particle radiation effects. Absorption depth vs. wavelength in silicon and a cross section of the CCD membrane are shown.

  14. Wide Field Infrared Survey Telescope [WFIRST]: Telescope Design and Simulated Performance

    NASA Technical Reports Server (NTRS)

    Goullioud, R.; Content, D. A.; Kuan, G. M.; Moore, J. D.; Chang, Z.; Sunada, E. T.; Villalvazo, J.; Hawk, J. P.; Armani, N. V.; Johnson, E. L.; Powell, C. A.

    2012-01-01

    The ASTRO2010 Decadal Survey proposed multiple missions with NIR focal planes and 3 mirror wide field telescopes in the 1.5m aperture range. None of them would have won as standalone missions WFIRST is a combination of these missions, created by Astro 2010 committee. WFIRST Science Definition Team (SDT) tasked to examine the design. Project team is a GSFC-JPL-Caltech collaboration. This interim mission design is a result of combined work by the project team with the SDT.

  15. The second generation Wide-Field/Planetary Camera on the Hubble Space Telescope

    NASA Technical Reports Server (NTRS)

    Leschly, Kim; Allestad, David; Herrell, Linda

    1991-01-01

    The general design and principal features of the second generation Wide-Field/Planetary Camera (WFPC-2) for the Hubble Space Telescope are reviewed. The discussion covers the background of WFPC-2 development, science capabilities, key performance parameters, optical and electronic equipment, mechanisms, thermal control, and contamination control. Attention is also given to on-orbit operations, including commanding and telemetry and on-orbit servicing.

  16. Using APART for wall visibility calculations in the calibration channel of wide field planetary camera II

    NASA Technical Reports Server (NTRS)

    Scholl, James W.; Scholl, Marija S.

    1993-01-01

    The cone visibility from the CCD detector array plane in the calibration channel of wide field planetary camera II (WFPC II) is analyzed, using APART, for three representative wavelengths as characterized by indices of refraction. The light pipe walls are visible from the corners of the equivalent CCD detector array when imaging with the smallest index of refraction, n = 1.375. Painting the inside of the light pipe walls will result in a decrease in their visibility.

  17. Wide field fluorescence imaging in narrow passageways using scanning fiber endoscope technology

    NASA Astrophysics Data System (ADS)

    Lee, Cameron M.; Chandler, John E.; Seibel, Eric J.

    2010-02-01

    An ultrathin scanning fiber endoscope (SFE) has been developed for high resolution imaging of regions in the body that are commonly inaccessible. The SFE produces 500 line color images at 30 Hz frame rate while maintaining a 1.2-1.7 mm outer diameter. The distal tip of the SFE houses a 9 mm rigid scan engine attached to a highly flexible tether (minimum bend radius < 8 mm) comprised of optical fibers and electrical wires within a protective sheath. Unlike other ultrathin technologies, the unique characteristics of this system have allowed the SFE to navigate narrow passages without sacrificing image quality. To date, the SFE has been used for in vivo imaging of the bile duct, esophagus and peripheral airways. In this study, the standard SFE operation was tailored to capture wide field fluorescence images and spectra. Green (523 nm) and blue (440 nm) lasers were used as illumination sources, while the white balance gain values were adjusted to accentuate red fluorescence signal. To demonstrate wide field fluorescence imaging of small lumens, the SFE was inserted into a phantom model of a human pancreatobiliary tract and navigated to a custom fluorescent target. Both wide field fluorescence and standard color images of the target were captured to demonstrate multimodal imaging.

  18. The Method of Measurements of Celestial Coordinates in Wide-Field TV-Frames

    NASA Astrophysics Data System (ADS)

    Kartashova, Anna P.

    2012-06-01

    We present a method for calculations of equatorial coordinates of any point in the single frame of the wide-field TV systems. This method can be applying for the different television systems [wide-field cameras, all-sky cameras, the cameras with the hybrid TV-system (the system with coupled of the Image Intensifier) et al.]. In that system the calculations of distortions are difficult. Therefore, we devised this method which helps decrease errors (due to distortion and the electro-optical system).The method can be used for measuring of equatorial coordinates of meteor tracks under difficult conditions during the observations such as partial cloudiness, small number of stars and large distortions of the coordinate grid in the frame. These restrictions cannot be overcome by other methods. In the case of the small number of stars the present method using of the reference stars received on a series of frames during the observation period. The accuracy of the method has been estimated to be 4'-8' (for cameras with fov 50° × 40° at the CCD 720 × 576 pixels) for maximum number of reference points in the frame. The method used 3 reference points for calculation of the equatorial coordinates of the object. One can use this method if the camera was re-oriented as well. We use this method for our wide field of view cameras.

  19. Design and implementation of coating hardware for the Hobby-Eberly Telescope wide-field corrector

    NASA Astrophysics Data System (ADS)

    Good, John; Lee, Hanshin; Hill, Gary J.; Vattiat, Brian; Perry, David; Kriel, Herman; Savage, Richard

    2014-07-01

    A major upgrade of the HET is in progress that will substantially increase the pupil size to 10 meters and the field of view to 22 arc-minutes by replacing the spherical aberration corrector. The new Wide Field Corrector is a 4-element assembly weighing 750kg and measuring 1.34 meters diameter by 2.1 meter in length. Special fixtures were required in order to support the mirrors of the Wide-Field Corrector and adapt them to the coaters chamber, during the vacuum coating process. For the 1 meter-class mirrors, the only suitable support interface was located on a 80mm wide cylindrical surface on the periphery of each mirror. The vacuum compatible system had to support the mirrors with the surface facing downward, and accommodate thermal ranges from ambient to 100C without inducing stresses in the substrate. The fixture also had to accommodate washing, as well as support of witness samples during testing and production runs, and provide masking for alignment fixtures in the center apertures of each mirror. Design principles, materials, implementation details, as well as lessons learned are covered*.

  20. Intra-familial Similarity of Wide-Field Fundus Autofluorescence in Inherited Retinal Dystrophy.

    PubMed

    Furutani, Yuka; Ogino, Ken; Oishi, Akio; Gotoh, Norimoto; Makiyama, Yukiko; Oishi, Maho; Kurimoto, Masafumi; Yoshimura, Nagahisa

    2016-01-01

    To examine the similarity of wide-field fundus autofluorescence (FAF) imaging in inherited retinal dystrophy between siblings and between parents and their children. The subjects included 17 siblings (12 with retinitis pigmentosa and 5 with cone rod dystrophy) and 10 parent-child pairs (8 with retinitis pigmentosa and 2 with cone rod dystrophy). We quantified the similarity of wide-field FAF using image processing techniques of cropping, binarization, superimposition, and subtraction. The estimated similarity of the siblings was compared with that of the parent-child pairs and that of the age-matched unrelated patients. The similarity between siblings was significantly higher that of parent-child pairs or that of age-matched unrelated patients (P = 0.004 and P = 0.049, respectively). Wide-field FAF images were similar between siblings with inherited retinal dystrophy but different between parent-child pairs. This suggests that aging is a confounding factor in genotype-phenotype correlation studies. PMID:26427425

  1. Wide-field heterodyne interferometric vibrometry for two-dimensional surface vibration measurement

    NASA Astrophysics Data System (ADS)

    Choi, Samuel; Maruyama, Yuta; Suzuki, Takamasa; Nin, Fumiaki; Hibino, Hiroshi; Sasaki, Osami

    2015-12-01

    Conventional laser Doppler vibrometry and heterodyne interferometry suffer during the simultaneous measurement of the spatial distribution of vibration parameters such as the amplitude, frequency and phase in a wide field of view. Although demand is increasing for methods that can measure vibrations over a wide field of view for a wide range of applications from industrial product inspections to biological measurements, full-field (FF) techniques for high-speed vibration measurements without a spatial scan are untapped. We propose a new method for high-speed FF vibration measurement that can easily be combined with profilometry and tomographic interferometry using a conventional CCD or CMOS camera. In principle, the measurable vibration frequency is unrestricted because the heterodyne signal produced by the modulated interferogram can be controlled to accommodate the CCD frame rate. The validity of the proposed method and the measurement accuracy of the spatial vibration amplitude were evaluated through simulations and experiments. In experiments, the spatial vibration parameters of a mirror vibrated at a frequency of 1 kHz and amplitude of approximately 5-65 nm were successfully measured with a spatial fluctuation of 3%-6.5%.

  2. Wide field-of-view dual-band multispectral muzzle flash detection

    NASA Astrophysics Data System (ADS)

    Montoya, J.; Melchor, J.; Spiliotis, P.; Taplin, L.

    2013-06-01

    Sensor technologies are undergoing revolutionary advances, as seen in the rapid growth of multispectral methodologies. Increases in spatial, spectral, and temporal resolution, and in breadth of spectral coverage, render feasible sensors that function with unprecedented performance. A system was developed that addresses many of the key hardware requirements for a practical dual-band multispectral acquisition system, including wide field of view and spectral/temporal shift between dual bands. The system was designed using a novel dichroic beam splitter and dual band-pass filter configuration that creates two side-by-side images of a scene on a single sensor. A high-speed CMOS sensor was used to simultaneously capture data from the entire scene in both spectral bands using a short focal-length lens that provided a wide field-of-view. The beam-splitter components were arranged such that the two images were maintained in optical alignment and real-time intra-band processing could be carried out using only simple arithmetic on the image halves. An experiment related to limitations of the system to address multispectral detection requirements was performed. This characterized the system's low spectral variation across its wide field of view. This paper provides lessons learned on the general limitation of key hardware components required for multispectral muzzle flash detection, using the system as a hardware example combined with simulated multispectral muzzle flash and background signatures.

  3. Wide-field four-channel fluorescence imager for biological applications

    NASA Astrophysics Data System (ADS)

    Thakur, Madhuri; Melnik, Dmitry; Barnett, Heather; Daly, Kevin; Moran, Christine H.; Chang, Wei-Shun; Link, Stephan; Bucher, Christopher Theodore; Kittrell, Carter; Curl, Robert

    2010-03-01

    A wide-field four-channel fluorescence imager has been developed. The instrument uses four expanded laser beams to image a large section (6 mm×9 mm). An object can be sequentially illuminated with any combination of 408-, 532-, 658-, and 784-nm lasers for arbitrary (down to 1 ms) exposure times for each laser. Just two notch filters block scattered light from all four lasers. The design approach described here offers great flexibility in treatment of objects, very good sensitivity, and a wide field of view at low cost. There appears to be no commercial instrument capable of simultaneous fluorescence imaging of a wide field of view with four-laser excitation. Some possible applications are following events such as flow and mixing in microchannel systems, the transmission of biological signals across a culture, and following simulations of biological membrane diffusion. It can also be used in DNA sequencing by synthesis to follow the progress of the photolytic removal of dye and terminator. Without utilizing its time resolution, it can be used to obtain four independent images of a single tissue section stained with four targeting agents, with each coupled to a different dye matching one of the lasers.

  4. HST/ACS Observations of RR Lyrae Stars in Six Ultra-Deep Fields of M31

    NASA Technical Reports Server (NTRS)

    Jeffery, E. J.; Smith, E.; Brown, T. M.; Sweigart, A. V.; Kalirai, J. S.; Ferguson, H. C.; Guhathakurta, P.; Renzini, A.; Rich, R. M.

    2010-01-01

    We present HST/ACS observations of RR Lyrae variable stars in six ultra deep fields of the Andromeda galaxy (M31), including parts of the halo, disk, and giant stellar stream. Past work on the RR Lyrae stars in M31 has focused on various aspects of the stellar populations that make up the galaxy s halo, including their distances and metallicities. This study builds upon this previous work by increasing the spatial coverage (something that has been lacking in previous studies) and by searching for these variable stars in constituents of the galaxy not yet explored. Besides the 55 RR Lyrae stars we found in our initial field located 11kpc from the galactic nucleus, we find additional RR Lyrae stars in four of the remaining five ultra deep fields as follows: 21 in the disk, 24 in the giant stellar stream, 3 in the halo field 21kpc from the galactic nucleus, and 5 in one of the halo fields at 35kpc. No RR Lyrae were found in the second halo field at 35kpc. The RR Lyrae populations of these fields appear to mostly be of Oosterhoff I type, although the 11kpc field appears to be intermediate or mixed. We will discuss the properties of these stars including period and reddening distributions. We calculate metallicities and distances for the stars in each of these fields using different methods and compare the results, to an extent that has not yet been done. We compare these methods not just on RR Lyrae in our M31 fields, but also on a data set of Milky Way field RR Lyrae stars.

  5. HST/ACS OBSERVATIONS OF RR LYRAE STARS IN SIX ULTRA-DEEP FIELDS OF M31

    SciTech Connect

    Jeffery, E. J.; Smith, E.; Brown, T. M.; Kalirai, J. S.; Ferguson, H. C.; Sweigart, A. V.; Rich, R. M.

    2011-05-15

    We present HST/ACS observations of RR Lyrae variable stars in six ultra-deep fields of the Andromeda galaxy (M31), including parts of the halo, disk, and giant stellar stream. Past work on the RR Lyrae stars in M31 has focused on various aspects of the stellar populations that make up the galaxy's halo, including their distances and metallicities. This study builds upon this previous work by increasing the spatial coverage (something that has been lacking in previous studies) and by searching for these variable stars in constituents of the galaxy not yet explored. Besides the 55 RR Lyrae stars we found in our initial field located 11 kpc from the galactic nucleus, we find additional RR Lyrae stars in four of the remaining five ultra-deep fields as follows: 21 in the disk, 24 in the giant stellar stream, three in the halo field 21 kpc from the galactic nucleus, and five in one of the halo fields at 35 kpc. No RR Lyrae stars were found in the second halo field at 35 kpc. The RR Lyrae populations of these fields appear to be mostly of Oosterhoff I type, although the 11 kpc field appears to be intermediate or mixed. We will discuss the properties of these stars including period and reddening distributions. We calculate metallicities and distances for the stars in each of these fields using different methods and compare the results, to an extent that has not yet been done. We compare these methods not just on RR Lyrae stars in our M31 fields, but also on a data set of Milky Way field RR Lyrae stars.

  6. A Wide-Field Survey in the Chandra Deep Field-South Region: A Combined GTO + GO Approach

    NASA Astrophysics Data System (ADS)

    Garmire, Gordon

    2013-09-01

    We propose to perform a wide-field (2.2 square degree) survey around the Chandra Deep Field-South (CDF-S) and Extended Chandra Deep Field-South (E-CDF-S). This survey will complement the large observational investments made in multi-square-degree surveys in the CDF-S region by Spitzer, Herschel, the Australia Telescope Compact Array, PRIMUS, Pan-STARRS, DES, LSST, and other facilities. It will allow us to identify the most-luminous active galaxies to z = 1.5-2 and to investigate large-scale structures in the CDF-S region. This is the GTO component of a GTO + GO project; the associated GO observations will be proposed as a Cycle 15 Large Project.

  7. KOALA: a wide-field 1000 element integral-field unit for the Anglo-Australian Telescope

    NASA Astrophysics Data System (ADS)

    Ellis, S. C.; Ireland, M.; Lawrence, J. S.; Tims, J.; Staszak, N.; Brzeski, J.; Parker, Q. A.; Sharp, R.; Bland-Hawthorn, J.; Case, S.; Colless, M.; Croom, S.; Couch, W.; De Marco, O.; Glazebrook, K.; Saunders, W.; Webster, R.; Zucker, D. B.

    2012-09-01

    KOALA, the Kilofibre Optimised Astronomical Lenslet Array, is a wide-field, high efficiency integral field unit being designed for use with the bench mounted AAOmega spectrograph on the AAT. KOALA will have 1000 fibres in a rectangular array with a selectable field of view of either 1390 or 430 sq. arcseconds with a spatial sampling of 1.25" or 0.7" respectively. To achieve this KOALA will use a telecentric double lenslet array with interchangeable fore-optics. The IFU will feed AAOmega via a 31m fibre run. The efficiency of KOALA is expected to be ≍ 52% at 3700A and ≍ 66% at 6563°Å with a throughput of > 52% over the entire wavelength range.

  8. Wide field fluorescent imaging of extracellular spatiotemporal potassium dynamics in vivo.

    PubMed

    Bazzigaluppi, Paolo; Dufour, Suzie; Carlen, Peter L

    2015-01-01

    Potassium homeostasis is fundamental for the physiological functioning of the brain. Increased [K(+)] in the extracellular fluid has a major impact on neuronal physiology and can lead to ictal events. Compromised regulation of extracellular [K(+)] is involved in generation of seizures in animal models and potentially also in humans. For this reason, the investigation of K(+) spatio-temporal dynamics is of fundamental importance for neuroscientists in the field of epilepsy and other related pathologies. To date, the majority of studies investigating changes in extracellular K(+) have been conducted using a micropipette filled with a K(+) sensitive solution. However, this approach presents a major limitation: the area of the measurement is circumscribed to the tip of the pipette and it is not possible to know the spatiotemporal distribution or origin of the focally measured K(+) signal. Here we propose a novel approach, based on wide field fluorescence, to measure extracellular K(+) dynamics in neural tissue. Recording the local field potential from the somatosensory cortex of the mouse, we compared responses obtained from a K(+)-sensitive microelectrode to the spatiotemporal increases in fluorescence of the fluorophore, Asante Potassium Green-2, in physiological conditions and during 4-AP induced ictal activity. We conclude that wide field imaging is a valuable and versatile tool to measure K(+) dynamics over a large area of the cerebral cortex and is capable of capturing fast dynamics such as during ictal events. Moreover, the present technique is potentially adaptable to address questions regarding spatiotemporal dynamics of other ionic species. PMID:25312775

  9. A comparison of super wide field microscopy systems in mohs surgery.

    PubMed

    Goldsberry, Anne; Hanke, C William; Countryman, Nicholas B

    2014-12-01

    Microscopic frozen section interpretation is one of the cornerstones of Mohs surgery. The recent development of super wide field (SWF) microscopy can improve accuracy and efficiency while reading microscope sections, and also decrease the physician's musculoskeletal and ocular strain. Super wide field microscopy systems increase viewable field area (VA) by combining low magnification objectives, eg, 1x or 2x (Figure 1), with eyepieces that have a higher field number. This article reviews 3 SWF microscopy systems: Leica DM2000 (Leica Microsystems, Wetzlar, Germany), Nikon Eclipse Ni (Nikon Instruments Inc., Melville, NY), and Olympus BX43 (Olympus, Center Valley, PA). The Leica DM2000's 1.25x objective results in a VA of 314.16 mm2. The Nikon Eclipse Ni's 1x objective results in a VA of 490.87 mm2. The Olympus BX43's 1.25x objective results in a VA of 352.99 mm2. The maximum VA at the lowest objective for Nikon is nearly 40% greater than for the Olympus and over 50% greater than for the Leica. The Nikon Eclipse Ni has a significantly higher maximum VA than the other 2 systems. PMID:25607789

  10. The 64 Mpixel wide field imager for the Wendelstein 2m telescope: design and calibration

    NASA Astrophysics Data System (ADS)

    Kosyra, Ralf; Gössl, Claus; Hopp, Ulrich; Lang-Bardl, Florian; Riffeser, Arno; Bender, Ralf; Seitz, Stella

    2014-11-01

    The Wendelstein Observatory of Ludwig Maximilians University of Munich has recently been upgraded with a modern 2m robotic telescope. One Nasmyth port of the telescope has been equipped with a wide-field corrector which preserves the excellent image quality (<0.8 " median seeing) of the site (Hopp et al. 2008) over a field of view of 0.7 degrees diameter. The available field is imaged by an optical imager (WWFI, the Wendelstein Wide Field Imager) built around a customized 2×2 mosaic of 4 k×4 k 15 μm e2v CCDs from Spectral Instruments. This paper provides an overview of the design and the WWFI's performance. We summarize the system mechanics (including a structural analysis), the electronics (and its electromagnetic interference (EMI) protection) and the control software. We discuss in detail detector system parameters, i.e. gain and readout noise, quantum efficiency as well as charge transfer efficiency (CTE) and persistent charges. First on sky tests yield overall good predictability of system throughput based on lab measurements.

  11. Prototyping results for a wide-field fiber positioner for the Giant Segmented Mirror Telescope

    NASA Astrophysics Data System (ADS)

    Moore, Anna M.; McGrath, Andrew J.

    2004-07-01

    Given the physical size of the GSMT prime focus field is approximately equivalent to that of the Subaru telescope it is possible to directly apply current technology developed for the Fiber Multi-Object Spectrograph instrument (FMOS, to be commissioned in 2005) and substantially reduce the risk associated with developing a new solution for wide-field multi-object spectroscopy on an ELT. The Anglo-Australian Observatory has recently completed a design study for an ~1000 fiber, Echidna-style positioner for the prime focus of the Giant Segmented Mirror Telescope (GSMT). The positioner forms part of the wide-field Multi-Object Multi-Fiber Optical Spectrograph (MOMFOS), an ELT prime focus instrument offering a minimum of 800 fibers patrolling the corrected 20 arcmin field. The design study identified 2 components of an equivalent MOMFOS positioner design that required prototyping. Firstly, a higher spine packing density is required to satisfy the proposed scientific program. Secondly, the fiber position measurement system adopted for FMOS cannot be simply scaled and applied to MOMFOS given space constraints in the top end unit. As such a new and, if possible, simpler system was required. Prototyping results for both components are presented.

  12. Grazing-incidence hyperboloid-hyperboloid designs for wide-field x-ray imaging applications.

    PubMed

    Harvey, J E; Krywonos, A; Thompson, P L; Saha, T T

    2001-01-01

    The classical Wolter type I grazing-incidence x-ray telescope consists of a paraboloidal primary mirror and a confocal hyperboloidal secondary mirror. This design exhibits stigmatic imaging on-axis but suffers from coma, astigmatism, field curvature, and higher-order aberrations such as oblique spherical aberration. Wolter-Schwarzschild designs have been developed that strictly satisfy the Abbe sine condition and thus exhibit no spherical aberration or coma. However, for wide-field applications such as the solar x-ray imager (SXI), there is little merit in a design with stigmatic imaging on-axis. Instead, one needs to optimize some area-weighted-average measure of resolution over the desired operational field of view. This has traditionally been accomplished by mere despacing of the focal plane of the classical Wolter type I telescope. Here we present and evaluate in detail a family of hyperboloid-hyperboloid grazing-incidence x-ray telescope designs whose wide-field performance is much improved over that of an optimally despaced Wolter type I and even somewhat improved over that of an optimally despaced Wolter-Schwarzschild design. PMID:18356984

  13. Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects

    PubMed Central

    Coskun, Ahmet F.; Sencan, Ikbal; Su, Ting-Wei; Ozcan, Aydogan

    2010-01-01

    We demonstrate the use of a compressive sampling algorithm for on-chip fluorescent imaging of sparse objects over an ultra-large field-of-view (>8 cm2) without the need for any lenses or mechanical scanning. In this lensfree imaging technique, fluorescent samples placed on a chip are excited through a prism interface, where the pump light is filtered out by total internal reflection after exciting the entire sample volume. The emitted fluorescent light from the specimen is collected through an on-chip fiber-optic faceplate and is delivered to a wide field-of-view opto-electronic sensor array for lensless recording of fluorescent spots corresponding to the samples. A compressive sampling based optimization algorithm is then used to rapidly reconstruct the sparse distribution of fluorescent sources to achieve ~10 µm spatial resolution over the entire active region of the sensor-array, i.e., over an imaging field-of-view of >8 cm2. Such a wide-field lensless fluorescent imaging platform could especially be significant for high-throughput imaging cytometry, rare cell analysis, as well as for micro-array research. PMID:20588904

  14. Simulation studies of wide and medium field of view earth radiation data analysis

    NASA Technical Reports Server (NTRS)

    Green, R. N.

    1978-01-01

    A parameter estimation technique is presented to estimate the radiative flux distribution over the earth from radiometer measurements at satellite altitude. The technique analyzes measurements from a wide field of view (WFOV), horizon to horizon, nadir pointing sensor with a mathematical technique to derive the radiative flux estimates at the top of the atmosphere for resolution elements smaller than the sensor field of view. A computer simulation of the data analysis technique is presented for both earth-emitted and reflected radiation. Zonal resolutions are considered as well as the global integration of plane flux. An estimate of the equator-to-pole gradient is obtained from the zonal estimates. Sensitivity studies of the derived flux distribution to directional model errors are also presented. In addition to the WFOV results, medium field of view results are presented.

  15. Deconvolution of wide field-of-view radiometer measurements of earth-emitted radiation. I - Theory

    NASA Technical Reports Server (NTRS)

    Smith, G. L.; Green, R. N.

    1981-01-01

    The theory of deconvolution of wide field-of-view (WFOV) radiometer measurements of earth-emitted radiation provides a technique by which the resolution of such measurements can be enhanced to provide radiant exitance at the top of the atmosphere with a finer resolution than the field of view. An analytical solution for the earth-emitted radiant exitance in terms of WFOV radiometer measurements is derived for the nonaxisymmetric (or regional) case, in which the measurements and radiant exitance are considered to be functions of both latitude and longitude. This solution makes it possible to deconvolve a set of WFOV radiometer measurements of earth-emitted radiation and obtain information with a finer resolution than the instantaneous field of view of the instrument. It is shown that there are tradeoffs involved in the selection between WFOV and scanning radiometers.

  16. WISPIR: A Wide-Field Imaging SPectrograph for the InfraRed for the SPICA Observatory

    NASA Technical Reports Server (NTRS)

    Benford, Dominic J.; Mundy, Lee G.

    2010-01-01

    We have undertaken a study of a far infrared imaging spectrometer based on a Fourier transform spectrometer that uses well-understood, high maturity optics, cryogenics, and detectors to further our knowledge of the chemical and astrophysical evolution of the Universe as it formed planets, stars, and the variety of galaxy morphologies that we observe today. The instrument, Wide-field Imaging Spectrometer for the InfraRed (WISPIR), would operate on the SPICA observatory, and will feature a spectral range from 35 - 210 microns and a spectral resolving power of R=1,000 to 6,000, depending on wavelength. WISPIR provides a choice of full-field spectral imaging over a 2'x2' field or long-slit spectral imaging along a 2' slit for studies of astrophysical structures in the local and high-redshift Universe. WISPIR in long-slit mode will attain a sensitivity two orders of magnitude better than what is currently available.

  17. Current status of the Hobby-Eberly Telescope wide-field upgrade

    NASA Astrophysics Data System (ADS)

    Savage, Richard; Booth, John; Cornell, Mark; Good, John; Hill, Gary J.; Lee, Hanshin; MacQueen, Phillip; Rafal, Marc; Vattiat, Brian; Gebhardt, Karl; Beno, Joseph; Zierer, Joseph; Perry, Dave; Rafferty, Tom; Ramiller, Chuck; Taylor, Charles, III; Beets, Timothy; Hayes, Richard; Heisler, James; Hinze, Sarah; Soukup, Ian; Jackson, John; Mock, Jason; Worthington, Michael; Mollison, Nicholas; Molina, Omar; South, Brian; Wardell, Douglas; Wedeking, Gregory

    2010-07-01

    The Hobby-Eberly Telescope (HET) is an innovative large telescope of 9.2 meter aperture, located in West Texas at the McDonald Observatory (MDO). The HET operates with a fixed segmented primary and has a tracker which moves the four-mirror corrector and prime focus instrument package to track the sidereal and non-sidereal motions of objects. A major upgrade of the HET is in progress that will increase the pupil size to 10 meters and the field of view to 22' by replacing the corrector, tracker and prime focus instrument package. In addition to supporting the existing suite of instruments, this wide field upgrade will feed a revolutionary new integral field spectrograph called VIRUS, in support of the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX‡). This paper discusses the current status of this upgrade.

  18. Current status of the Hobby-Eberly Telescope wide field upgrade

    NASA Astrophysics Data System (ADS)

    Hill, Gary J.; Booth, John A.; Cornell, Mark E.; Good, John M.; Gebhardt, Karl; Kriel, Herman J.; Lee, Hanshin; Leck, Ron; Moreira, Walter; MacQueen, Phillip J.; Perry, Dave M.; Rafal, Marc D.; Rafferty, Tom H.; Ramiller, Chuck; Savage, Richard D.; Taylor, Charles A.; Vattiat, Brian L.; Ramsey, Lawrence W.; Beno, Joseph H.; Beets, Timothy A.; Esguerra, Jorge D.; Häuser, Marco; Hayes, Richard J.; Heisler, James T.; Soukup, Ian M.; Zierer, Joseph J.; Worthington, Michael S.; Mollison, Nicholas T.; Wardell, Douglas R.; Wedeking, Gregory A.

    2012-09-01

    The Hobby-Eberly Telescope (HET) is an innovative large telescope of 9.2 meter aperture, located in West Texas at the McDonald Observatory (MDO). The HET operates with a fixed segmented primary and has a tracker which moves the four-mirror corrector and prime focus instrument package to track the sidereal and non-sidereal motions of objects. A major upgrade of the HET is in progress that will increase the pupil size to 10 meters and the field of view to 22' by replacing the corrector, tracker and prime focus instrument package. In addition to supporting the existing suite of instruments, this wide field upgrade will feed a revolutionary new integral field spectrograph called VIRUS, in support of the Hobby-Eberly Telescope Dark Energy Experiment (HETDEXχ). This paper discusses the current status of this upgrade.

  19. Current status of the Hobby-Eberly Telescope wide field upgrade and VIRUS

    NASA Astrophysics Data System (ADS)

    Savage, Richard D.; Booth, John A.; Gebhardt, Karl; Good, John M.; Hill, Gary J.; MacQueen, Phillip J.; Rafal, Marc D.; Smith, Michael P.; Vattiat, Brian L.

    2008-07-01

    The Hobby-Eberly Telescope (HET) is an innovative large telescope of 9.2 meter aperture, located in West Texas at the McDonald Observatory. The HET operates with a fixed segmented primary and has a tracker which moves the fourmirror corrector and prime focus instrument package to track the sidereal and non-sidereal motions of objects. A major upgrade of the HET is in progress that will substantially increase the field of view by replacing the corrector, tracker and prime focus instrument package. In addition to supporting the existing suite of instruments, this wide field upgrade will feed a revolutionary new integral field spectrograph called VIRUS, in support of the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX). This paper discusses the current status of this upgrade.

  20. Wide field x-ray telescopes: Detecting x-ray transients/afterglows related to GRBs

    SciTech Connect

    Hudec, Rene; Pina, Ladislav; Inneman, Adolf; Gorenstein, Paul

    1998-05-16

    The recent discovery of X-ray afterglows of GRBs opens the possibility of analyses of GRBs by their X-ray detections. However, imaging X-ray telescopes in current use mostly have limited fields of view. Alternative X-ray optics geometries achieving very large fields of view have been theoretically suggested in the 70's but not constructed and used so far. We review the geometries and basic properties of the wide-field X-ray optical systems based on one- and two-dimensional lobster-eye geometry and suggest technologies for their development and construction. First results of the development of double replicated X-ray reflecting flats for use in one-dimensional X-ray optics of lobster-eye type are presented and discussed. The optimum strategy for locating GRBs upon their X-ray counterparts is also presented and discussed.

  1. The Wide-Field Nearby Galaxy-Cluster Survey (WINGS) and Its Extension OMEGAWINGS

    NASA Astrophysics Data System (ADS)

    Poggianti, B. M.; Fasano, G.; Bettoni, D.; Cava, A.; Couch, W.; D'Onofrio, M.; Dressler, A.; Fritz, J.; Kjaergaard, P.; Gullieuszik, M.; Moles, M.; Moretti, A.; Omizzolo, A.; Paccagnella, A.; Varela, J.; Vulcani, B.

    WINGS is a wide-field multi-wavelength survey of 76 X-ray selected clusters at low redshift. The WINGS database has been used for a variety of cluster and cluster galaxy studies, investigating galaxy star formation, morphologies, structure, stellar mass functions and other properties. We present the recent wider-field extension of WINGS, OMEGAWINGS, conducted with OmegaCAM@VST and AAOmega@AAT. We show two of our latest results regarding jellyfish galaxies and galaxy sizes. OMEGAWINGS has allowed the first systematic search of galaxies with signs of ongoing ram pressure stripping (jellyfishes), yielding a catalog of ˜ 240 galaxies in 41 clusters. We discuss the first results obtained from this sample and the prospects for integral field data. Finally, we summarize our results regarding the discovery of compact massive galaxies at low redshift, their properties, dependence on environment and the implications for the evolution of galaxy sizes from high- to low-z.

  2. Characterization of spatially varying aberrations for wide field-of-view microscopy

    PubMed Central

    Zheng, Guoan; Ou, Xiaoze; Horstmeyer, Roarke; Yang, Changhuei

    2013-01-01

    We describe a simple and robust approach for characterizing the spatially varying pupil aberrations of microscopy systems. In our demonstration with a standard microscope, we derive the location-dependent pupil transfer functions by first capturing multiple intensity images at different defocus settings. Next, a generalized pattern search algorithm is applied to recover the complex pupil functions at ~350 different spatial locations over the entire field-of-view. Parameter fitting transforms these pupil functions into accurate 2D aberration maps. We further demonstrate how these aberration maps can be applied in a phase-retrieval based microscopy setup to compensate for spatially varying aberrations and to achieve diffraction-limited performance over the entire field-of-view. We believe that this easy-to-use spatially-varying pupil characterization method may facilitate new optical imaging strategies for a variety of wide field-of-view imaging platforms. PMID:23842300

  3. All-spherical catadioptric telescope design for wide-field imaging.

    PubMed

    Bahrami, Mehdi; Goncharov, Alexander V

    2010-10-20

    The current trend in building medium-size telescopes for wide-field imaging is to use a Ritchey-Chrétien (RC) design with a multilens corrector near the focus. Our goal is to find a cost-effective alternative design to the RC system for seeing-limited observations. We present an f/4.5 all-spherical catadioptric system with a 1.5° field of view. The system consists of a 0.8 m spherical primary and 0.4 m flat secondary mirror combined with a meniscus lens and followed by a three-lens field corrector. The optical performance is comparable to an equivalent f/4.5 RC system. We conclude that, for telescopes with apertures up to 2 m, the catadioptric design is a good alternative to the RC system. PMID:20962933

  4. Wide-field direct CCD observations supporting the Astro-1 Space Shuttle mission's Ultraviolet Imaging Telescope

    NASA Technical Reports Server (NTRS)

    Hintzen, Paul; Angione, Ron; Talbert, Freddie; Cheng, K.-P.; Smith, Eric; Stecher, Theodore P.

    1993-01-01

    Wide field direct CCD observations are being obtained to support and complement the vacuum-ultraviolet (VUV) images provided by Astro's Ultraviolet Imaging Telescope (UIT) during a Space Shuttle flight in December 1990. Because of the wide variety of projects addressed by UIT, the fields observed include (1) galactic supernova remnants such as the Cygnus Loop and globular clusters such as Omega Cen and M79; (2) the Magellanic Clouds, M33, M81, and other galaxies in the Local Group; and (3) rich clusters of galaxies, principally the Perseus cluster and Abell 1367. Ground-based observations have been obtained for virtually all of the Astro-1 UIT fields. The optical images allow identification of individual UV sources in each field and provide the long baseline in wavelength necessary for accurate analysis of UV-bright sources. To facilitate use of our optical images for analysis of UIT data and other projects, we plan to archive them, with the UIT images, at the National Space Science Data Center (NSSDC), where they will be universally accessible via anonymous FTP. The UIT, one of three telescopes comprising the Astro spacecraft, is a 38-cm f/9 Ritchey-Chretien telescope on which high quantum efficiency, solar-blind image tubes are used to record VUV images on photographic film. Five filters with passbands centered between 1250A and 2500A provide both VUV colors and a measurement of extinction via the 2200A dust feature. The resulting calibrated VUV pictures are 40 arcminutes in diameter at 2.5 arcseconds resolution. The capabilities of UIT, therefore, complement HST's WFPC: the latter has 40 times greater collecting area, while UIT's usable field has 170 times WFPC's field area.

  5. Tools and Setups for Experiments with AC and Rotating Magnetic Fields

    ERIC Educational Resources Information Center

    Ponikvar, D.

    2010-01-01

    A rotating magnetic field is the basis for the transformation of electrical energy to mechanical energy. School experiments on the rotating magnetic field are rare since they require the use of specially prepared mechanical setups and/or relatively large, three-phase power supplies to achieve strong magnetic fields. This paper proposes several…

  6. A wide field-of-view microscope based on holographic focus grid

    NASA Astrophysics Data System (ADS)

    Wu, Jigang; Cui, Xiquan; Zheng, Guoan; Lee, Lap Man; Yang, Changhuei

    2010-02-01

    We have developed a novel microscope technique that can achieve wide field-of-view (FOV) imaging and yet possess resolution that is comparable to conventional microscope. The principle of wide FOV microscope system breaks the link between resolution and FOV magnitude of traditional microscopes. Furthermore, by eliminating bulky optical elements from its design and utilizing holographic optical elements, the wide FOV microscope system is more cost-effective. In our system, a hologram was made to focus incoming collimated beam into a focus grid. The sample is put in the focal plane and the transmissions of the focuses are detected by an imaging sensor. By scanning the incident angle of the incoming beam, the focus grid will scan across the sample and the time-varying transmission can be detected. We can then reconstruct the transmission image of the sample. The resolution of microscopic image is limited by the size of the focus formed by the hologram. The scanning area of each focus spot is determined by the separation of the focus spots and can be made small for fast imaging speed. We have fabricated a prototype system with a 2.4-mm FOV and 1-μm resolution. The prototype system was used to image onion skin cells for a demonstration. The preliminary experiments prove the feasibility of the wide FOV microscope technique, and the possibility of a wider FOV system with better resolution.

  7. Influence of electrical fields (AC and DC) on phytoremediation of metal polluted soils with rapeseed (Brassica napus) and tobacco (Nicotiana tabacum).

    PubMed

    Bi, Ran; Schlaak, Michael; Siefert, Eike; Lord, Richard; Connolly, Helen

    2011-04-01

    The combined use of electrokinetic remediation and phytoremediation to decontaminate soil polluted with heavy metals has been demonstrated in a laboratory-scale experiment. The plants species selected were rapeseed and tobacco. Three kinds of soil were used: un-contaminated soil from forest area (S1), artificially contaminated soil with 15mgkg(-1) Cd (S2) and multi-contaminated soil with Cd, Zn and Pb from an industrial area (S3). Three treatment conditions were applied to the plants growing in the experimental vessels: control (no electrical field), alternating current electrical field (AC, 1Vcm(-1)) and direct current electrical field (DC, 1Vcm(-1)) with switching polarity every 3h. The electrical fields were applied for 30d for rapeseed and 90d for tobacco, each experiment had three replicates. After a total of 90d growth for rapeseed and of 180d for tobacco, the plants were harvested. The pH variation from anode to cathode was eliminated by switching the polarity of the DC field. The plants reacted differently under the applied electrical field. Rapeseed biomass was enhanced under the AC field and no negative effect was found under DC field. However, no enhancement of the tobacco biomass under the AC treatment was found. The DC field had a negative influence on biomass production on tobacco plants. In general, Cd content was higher in both species growing in S2 treated with AC field compared to the control. Metal uptake (Cd, Cu, Zn and Pb) per rapeseed plant shoot was enhanced by the application of AC field in all soils. PMID:21237480

  8. Hyperboloid-hyperboloid grazing incidence x-ray telescope designs for wide-field imaging applications

    NASA Astrophysics Data System (ADS)

    Harvey, James E.; Thompson, Patrick L.; Krywonos, Andrey

    2000-07-01

    The classical Wolter Type 1 X-ray telescope consists of two grazing incidence mirrors, a confocal paraboloid and hyperboloid. This design exhibits perfect geometric imaging on-axis (i.e., no spherical aberration) but suffers from severe field curvature, coma, astigmatism, and higher-order aberrations such as oblique spherical aberration. The Wolter-Schwarzschild design, consisting of two general aspheric grazing incidence surfaces, is corrected for both spherical aberration and coma, thus yielding very good geometrical performance at small field angles that becomes severely degraded at large field angles. The image quality criterion for stellar (small-field) X-ray telescopes is frequently expressed in terms of an on-axis fractional encircled energy, with the off-axis performance being dictated by the field-dependent aberrations characteristic of the design. A more appropriate image quality criterion for wide-angle applications is some area-weighted-average measure of resolution that maximizes the number of spatial resolution elements over a given operational field-of-view (OFOV). In practice, scattering effects from residual optical fabrication errors and detector effects (finite pixel size and charge spreading) dominate geometrical aberrations for small field angles whereas the geometrical aberrations dominate the image degradation at large field angles. Under these conditions, there is little merit in a telescope design corrected for coma (or even spherical aberration). Our new image quality criterion has led us to a whole new class of generalized Wolter Type I (hyperboloid- hyperboloid) designs that can be optimized for a given OFOV. A specific design and its predicted systems performance for the Solar X-ray Imager mission are described in detail.

  9. NOTE: Multileaf collimator end leaf leakage: implications for wide-field IMRT

    NASA Astrophysics Data System (ADS)

    Hardcastle, N.; Metcalfe, P.; Ceylan, A.; Williams, M. J.

    2007-11-01

    The multi-leaf collimator (MLC) of a particular linear accelerator vendor (Millennium MLC, Varian Medical Systems, Palo Alto, CA, USA) has a maximum leaf extension of 14.5 cm. To achieve intensity modulated radiotherapy (IMRT) for fields wider than 14.5 cm all closed leaf pairs are restricted to placement inside the field. Due to the rounded leaf end design of the MLC end leaf leakage will occur in the treatment field. The implementation of direct aperture optimization in the IMRT module of a radiotherapy treatment planning system (Pinnacle, Philips Radiation Oncology Systems, Milpitas, CA) has facilitated the delivery of IMRT fields wider than 14.5 cm. The end leaf leakage of the Millennium MLC has been characterized for 6 MV photons using gafchromic and radiographic film, and the accuracy of the planning system verified. The maximum leakage measured for a single field was 0.39 cGy MU-1 for a 0 mm leaf gap and 0.51 cGy MU-1 for a 0.6 mm leaf gap. For a clinical IMRT field leaf end leakage contributed an additional 2-3 Gy over the course of treatment. The planning system underestimated the magnitude of end leaf leakage by 20-40%. The ability to deliver IMRT fields wider than 14.5 cm with the Millennium MLC has improved the efficiency and flexibility of IMRT treatments; however, significant extra dose can be introduced due to end leaf leakage. Caution should be exercised when delivering wide field IMRT as it is not a complete panacea. Any significant occurrences of end leaf leakage predicted by the planning system should be independently verified prior to delivery.

  10. Microlensing Surveys of M31 in the Wide Field Imaging ERA

    SciTech Connect

    Baltz, E.

    2004-10-27

    The Andromeda Galaxy (M31) is the closest large galaxy to the Milky Way, thus it is an important laboratory for studying massive dark objects in galactic halos (MACHOs) by gravitational microlensing. Such studies strongly complement the studies of the Milky Way halo using the Large and Small Magellanic Clouds. We consider the possibilities for microlensing surveys of M31 using the next generation of wide field imaging telescopes with fields of view in the square degree range. We consider proposals for such imagers both on the ground and in space. For concreteness, we specialize to the SNAP proposal for a space telescope and the LSST proposal for a ground based telescope. We find that a modest space-based survey of 50 visits of one hour each is considerably better than current ground based surveys covering 5 years. Crucially, systematic effects can be considerably better controlled with a space telescope because of both the infrared sensitivity and the angular resolution. To be competitive, 8 meter class wide-field ground based imagers must take exposures of several hundred seconds with several day cadence.

  11. Wide-field optical coherence microscopy of the mouse brain slice.

    PubMed

    Min, Eunjung; Lee, Junwon; Vavilin, Andrey; Jung, Sunwoo; Shin, Sungwon; Kim, Jeehyun; Jung, Woonggyu

    2015-10-01

    The imaging capability of optical coherence microscopy (OCM) has great potential to be used in neuroscience research because it is able to visualize anatomic features of brain tissue without labeling or external contrast agents. However, the field of view of OCM is still narrow, which dilutes the strength of OCM and limits its application. In this study, we present fully automated wide-field OCM for mosaic imaging of sliced mouse brains. A total of 308 segmented OCM images were acquired, stitched, and reconstructed as an en-face brain image after intensive imaging processing. The overall imaging area was 11.2×7.0  mm (horizontal×vertical), and the corresponding pixel resolution was 1.2×1.2  μm. OCM images were compared to traditional histology stained with Nissl and Luxol fast blue (LFB). In particular, the orientation of the fibers was analyzed and quantified in wide-field OCM. PMID:26421546

  12. New wide field camera for Subaru Telescope: Hyper Suprime-Cam

    NASA Astrophysics Data System (ADS)

    Miyazaki, Satoshi

    2015-08-01

    Hyper Suprime-Cam (HSC) is a new wide field optical imaging camera built for 8.2 m Subaru telescope. The field of view is 1.5 degree in diameter and the nearly 50 cm image circle was paved by 116 fully depleted CCDs (2k x 4k 15 micron square pixels). To realize a seeing limit imaging at Mauna Kea, the specification on the overall instrument PSF is set as 0.32 arc-second (FWHM). This is crucial for our primary scientific objectives: weak gravitational lensing survey to probe dark matter distribution. We started building the camera in 2006 and had a first light in 2012. The delivered image quality turned out to be mostly seeing limited as designed. We once observed the seeing size of 0.43 arc-second (median value over the field of view) in Y-band with 300 seconds exposure. Our 300 nights observing proposal has been accepted. The program started in March 2014 and continues over 5 years. The wide survey plans to cover 1,400 square degree with the limiting magnitude of i_AB = 26 (5 sigma, 2 arcsec aperture). General observer programs are carried out in parallel. In this talk, we will present the design and the actual performance of the camera as well as how we implement the massive (1.6 GByte/exposure) data management system.

  13. Palm-size wide-field Fourier spectroscopic imager with uncooled infrared microbolometer arrays for smartphone

    NASA Astrophysics Data System (ADS)

    Kawashima, Natsumi; Suzuki, Yo; Qi, Wei; Hosono, Satsuki; Saito, Tsubasa; Ogawa, Satoshi; Sato, Shun; Fujiwara, Masaru; Nishiyama, Akira; Wada, Kenji; Tanaka, Naotaka; Ishimaru, Ichiro

    2015-03-01

    We proposed the imaging-type 2-dimensional Fourier spectroscopy that is a near-common-path interferometer with strong robustness against mechanical vibrations. We introduced the miniature uncooled infrared microbolometer arrays for smartphone (e.g. product name: FILR ONE price: around 400USD). And we constructed the phase-shifter with the piezo impact drive mechanism (maker: Technohands.co.Ltd., stroke: 4.5mm, resolution: 0.01μm, size: 20mm, price: around 800USD). Thus, we realized the palm-size mid-infrared spectroscopic imager [size: L56mm×W69mm×H43mm weight: 500g]. And by using wide-angle lens as objective lens, the proposed method can obtain the wide-field 2- dimensional middle-infrared (wavelength: 7.5-13.5[μm]) spectroscopic imaging of radiation lights emitted from human bodies itself

  14. Readout electronics for the Wide Field of view Cherenkov/Fluorescence Telescope Array

    NASA Astrophysics Data System (ADS)

    Zhang, J.; Zhang, S.; Zhang, Y.; Zhou, R.; Bai, L.; Zhang, J.; Huang, J.; Yang, C.; Cao, Z.

    2015-08-01

    The aim of the Large High Altitude Air Shower Observatory (LHAASO), supported by IHEP of the Chinese Academy of Sciences, is a multipurpose project with a complex detectors array for high energy gamma ray and cosmic ray detection. The Wide Field of view Cherenkov Telescope Array (WFCTA), as one of the components of the LHAASO project, aim to tag each primary particle that causes an air shower. The WFCTA is a portable telescope array used to detect cosmic ray spectra. The design of the readout electronics of the WFCTA is described in this paper Sixteen photomultiplier tubes (PMTs), together with their readout electronics are integrated into a single sub-cluster. To maintain good resolution and linearity over a wide dynamic range, a dual-gain amplification configuration on an analog board is used The digital board contains two 16channel 14-bit, 50 Msps analog-to-digital converters (ADC) and its power consumption, noise level, and relative deviation are all tested.

  15. Wide field of view laser beacon system for three-dimensional aircraft position measurement

    NASA Technical Reports Server (NTRS)

    Sweet, L. M.; Miles, R. B.; Webb, S. G.; Wong, E. Y.

    1981-01-01

    This paper presents a new wide field of view laser beacon system for measurement, in three dimensions, of aircraft or other remote objects. The system is developed for aircraft collision hazard warning independent of ground-based hardware, as well as for flight research, helicopter-assisted construction and rescue, and robotic manipulation applications. Accurate information describing the relative range, elevation, and azimuth of the aircraft are generated by the sweep of a low-power fan-shaped rotating laser beacon past an array of optical detectors. The system achieves a wide angle of acceptance of laser beacon light through use of compound parabolic concentrators, which collimate the light for spectral filtering to minimize solar interference. An on-board microprocessor system converts the pulse sequence to aircraft position in real time. System reliability and performance are enhanced through narrow pass filtering of the pulse signals, digital logic design to mask spurious signals, and adaptive modulation of trigger threshold levels.

  16. Measurements on magnetized GdBCO pellets subjected to small transverse ac magnetic fields at very low frequency: Evidence for a slowdown of the magnetization decay

    NASA Astrophysics Data System (ADS)

    Fagnard, Jean-Francois; Kirsch, Sébastien; Morita, Mitsuru; Teshima, Hidekazu; Vanderheyden, Benoit; Vanderbemden, Philippe

    2015-05-01

    Due to their ability to trap large magnetic inductions, superconducting bulk materials can be used as powerful permanent magnets. The permanent magnetization of such materials, however, can be significantly affected by the application of several cycles of a transverse variable magnetic field. In this work, we study, at T = 77 K, the long term influence of transverse ac magnetic fields of small amplitudes (i.e. much smaller than the full penetration field) on the axial magnetization of a bulk single grain superconducting GdBCO pellet over a wide range of low frequencies (1 mHz-20 Hz). Thermocouples are placed against the pellet surface to probe possible self-heating of the material during the experiments. A high sensitivity cryogenic Hall probe is placed close to the surface to record the local magnetic induction normal to the surface. The results show first that, for a given number of applied triangular transverse cycles, higher values of dBapp/dt induce smaller magnetization decays. An important feature of practical interest is that, after a very large number of cycles which cause the loss of a substantial amount of magnetization (depending on the amplitude and the frequency of the field), the rate of the magnetization decay goes back to its initial value, corresponding to the relaxation of the superconducting currents due to flux creep only. In the amplitude and frequency range investigated, the thermocouples measurements and a 2D magneto-thermal modelling show no evidence of sufficient self-heating to affect the magnetization so that the effect of the transverse magnetic field cycles on the trapped magnetic moment is only attributed to a redistribution of superconducting currents in the volume of the sample and not to a thermal effect.

  17. Wide field-of-view fluorescence image deconvolution with aberration-estimation from Fourier ptychography

    PubMed Central

    Chung, Jaebum; Kim, Jinho; Ou, Xiaoze; Horstmeyer, Roarke; Yang, Changhuei

    2016-01-01

    This paper presents a method to simultaneously acquire an aberration-corrected, wide field-of-view fluorescence image and a high-resolution coherent bright-field image using a computational microscopy method. First, the procedure applies Fourier ptychographic microscopy (FPM) to retrieve the amplitude and phase of a sample, at a resolution that significantly exceeds the cutoff spatial frequency of the microscope objective lens. At the same time, redundancy within the set of acquired FPM bright-field images offers a means to estimate microscope aberrations. Second, the procedure acquires an aberrated fluorescence image, and computationally improves its resolution through deconvolution with the estimated aberration map. An experimental demonstration successfully improves the bright-field resolution of fixed, stained and fluorescently tagged HeLa cells by a factor of 4.9, and reduces the error caused by aberrations in a fluorescence image by up to 31%, over a field of view of 6.2 mm by 9.3 mm. For optimal deconvolution, we show the fluorescence image needs to have a signal-to-noise ratio of at least ~18. PMID:26977345

  18. Wide field-of-view fluorescence image deconvolution with aberration-estimation from Fourier ptychography.

    PubMed

    Chung, Jaebum; Kim, Jinho; Ou, Xiaoze; Horstmeyer, Roarke; Yang, Changhuei

    2016-02-01

    This paper presents a method to simultaneously acquire an aberration-corrected, wide field-of-view fluorescence image and a high-resolution coherent bright-field image using a computational microscopy method. First, the procedure applies Fourier ptychographic microscopy (FPM) to retrieve the amplitude and phase of a sample, at a resolution that significantly exceeds the cutoff spatial frequency of the microscope objective lens. At the same time, redundancy within the set of acquired FPM bright-field images offers a means to estimate microscope aberrations. Second, the procedure acquires an aberrated fluorescence image, and computationally improves its resolution through deconvolution with the estimated aberration map. An experimental demonstration successfully improves the bright-field resolution of fixed, stained and fluorescently tagged HeLa cells by a factor of 4.9, and reduces the error caused by aberrations in a fluorescence image by up to 31%, over a field of view of 6.2 mm by 9.3 mm. For optimal deconvolution, we show the fluorescence image needs to have a signal-to-noise ratio of at least ~18. PMID:26977345

  19. Calibration of Wide-Field Deconvolution Microscopy for Quantitative Fluorescence Imaging

    PubMed Central

    Lee, Ji-Sook; Wee, Tse-Luen (Erika); Brown, Claire M.

    2014-01-01

    Deconvolution enhances contrast in fluorescence microscopy images, especially in low-contrast, high-background wide-field microscope images, improving characterization of features within the sample. Deconvolution can also be combined with other imaging modalities, such as confocal microscopy, and most software programs seek to improve resolution as well as contrast. Quantitative image analyses require instrument calibration and with deconvolution, necessitate that this process itself preserves the relative quantitative relationships between fluorescence intensities. To ensure that the quantitative nature of the data remains unaltered, deconvolution algorithms need to be tested thoroughly. This study investigated whether the deconvolution algorithms in AutoQuant X3 preserve relative quantitative intensity data. InSpeck Green calibration microspheres were prepared for imaging, z-stacks were collected using a wide-field microscope, and the images were deconvolved using the iterative deconvolution algorithms with default settings. Afterwards, the mean intensities and volumes of microspheres in the original and the deconvolved images were measured. Deconvolved data sets showed higher average microsphere intensities and smaller volumes than the original wide-field data sets. In original and deconvolved data sets, intensity means showed linear relationships with the relative microsphere intensities given by the manufacturer. Importantly, upon normalization, the trend lines were found to have similar slopes. In original and deconvolved images, the volumes of the microspheres were quite uniform for all relative microsphere intensities. We were able to show that AutoQuant X3 deconvolution software data are quantitative. In general, the protocol presented can be used to calibrate any fluorescence microscope or image processing and analysis procedure. PMID:24688321

  20. The development of a wide-field, high-resolution UV Raman hyperspectral imager

    NASA Astrophysics Data System (ADS)

    Gomer, Nathaniel R.; Nelson, Matthew P.; Angel, S. M.

    2015-05-01

    Raman spectroscopy is a valuable tool for the investigation and analysis of explosive and biological analytes because it provides a unique molecular fingerprint that allows for unambiguous target identification. Raman can be advantageous when utilized with deep UV excitation, but typical deep UV Raman systems have numerous limitations that hinder their performance and make their potential integration onto a field portable platform difficult. These systems typically offer very low throughput, are physically large and heavy, and can only probe an area the size of a tightly focused laser, severely diminishing the ability of the system to investigate large areas efficiently. The majority of these limitations are directly related to a system's spectrometer, which is typically dispersive grating based and requires a very narrow slit width and long focal length optics to achieve high spectral resolution. To address these shortcomings, ChemImage Sensor Systems (CISS), teaming with the University of South Carolina, are developing a revolutionary wide-field Raman hyperspectral imaging system capable of providing wide-area, high resolution measurements with greatly increased throughput in a small form factor, which would revolutionize the way Raman is conducted and applied. The innovation couples a spatial heterodyne spectrometer (SHS), a novel slit-less spectrometer that operates similar to Michelson interferometer, with a fiber array spectral translator (FAST) fiber array, a two-dimensional imaging fiber for hyperspectral imagery. This combination of technologies creates a novel wide-field, high throughput Raman hyperspectral imager capable of yielding very high spectral resolution measurements using defocused excitation, giving the system a greater area coverage and faster search rate than traditional Raman systems. This paper will focus on the need for an innovative UV Raman system, provide an overview of spatial heterodyne Raman spectroscopy, and discuss the development

  1. Wide-range Vacuum Measurements from MWNT Field Emitters Grown Directly on Stainless Steel Substrates.

    PubMed

    Zhang, Jian; Li, Detian; Zhao, Yangyang; Cheng, Yongjun; Dong, Changkun

    2016-12-01

    The field emission properties and the vacuum measurement application are investigated from the multi-walled carbon nanotubes (MWNTs) grown directly on catalytic stainless steel substrates. The MWNT emitters present excellent emission properties after the acid treatment of the substrate. The MWNT gauge is able to work down to the extreme-high vacuum (XHV) range with linear measurement performance in wide range from 10(-11) to 10(-6) Torr. A modulating grid is attempted with improved gauge sensitivity. The extension of the lower pressure limit is attributed largely to low outgassing effect due to direct growth of MWNTs and justified design of the electron source. PMID:26738501

  2. Micrometeoroid Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Larger Particles

    NASA Technical Reports Server (NTRS)

    Kearsley, A. T.; Grime, G. W.; Webb, R. P.; Jeynes, C.; Palitsin, V.; Colaux, J. L.; Ross, D. K.; Anz-Meador, P.; Liou, J. C.; Opiela, J.; Griffin, G. T.; Gerlach, L.; Wozniakiewicz, P. J.; Price, M. C.; Burchell, M. J.; Cole, M. J.

    2014-01-01

    The Wide Field and Planetary Camera 2 (WFPC2) was returned from the Hubble Space Telescope (HST) by shuttle mission STS-125 in 2009. In space for 16 years, the surface accumulated hundreds of impact features on the zinc orthotitanate paint, some penetrating through into underlying metal. Larger impacts were seen in photographs taken from within the shuttle orbiter during service missions, with spallation of paint in areas reaching 1.6 cm across, exposing alloy beneath. Here we describe larger impact shapes, the analysis of impactor composition, and the micrometeoroid (MM) types responsible.

  3. Range performance of the DARPA AWARE wide field-of-view visible imager.

    PubMed

    Nichols, J M; Judd, K P; Olson, C C; Novak, K; Waterman, J R; Feller, S; McCain, S; Anderson, J; Brady, D

    2016-06-01

    In a prior paper, we described a new imaging architecture that addresses the need for wide field-of-view imaging combined with the resolution required to identify targets at long range. Over the last two years substantive improvements have been made to the system, both in terms of the size, weight, and power of the camera as well as to the optics and data management software. The result is an overall improvement in system performance, which we demonstrate via a maritime target identification experiment. PMID:27411206

  4. Wide-range Vacuum Measurements from MWNT Field Emitters Grown Directly on Stainless Steel Substrates

    NASA Astrophysics Data System (ADS)

    Zhang, Jian; Li, Detian; Zhao, Yangyang; Cheng, Yongjun; Dong, Changkun

    2016-01-01

    The field emission properties and the vacuum measurement application are investigated from the multi-walled carbon nanotubes (MWNTs) grown directly on catalytic stainless steel substrates. The MWNT emitters present excellent emission properties after the acid treatment of the substrate. The MWNT gauge is able to work down to the extreme-high vacuum (XHV) range with linear measurement performance in wide range from 10-11 to 10-6 Torr. A modulating grid is attempted with improved gauge sensitivity. The extension of the lower pressure limit is attributed largely to low outgassing effect due to direct growth of MWNTs and justified design of the electron source.

  5. DWARF IRREGULAR GALAXY LEO A: SUPRIME-CAM WIDE-FIELD STELLAR PHOTOMETRY

    SciTech Connect

    Stonkutė, Rima; Narbutis, Donatas; Vansevičius, Vladas; Arimoto, Nobuo; Hasegawa, Takashi; Tamura, Naoyuki

    2014-10-01

    We have surveyed a complete extent of Leo A—an apparently isolated gas-rich low-mass dwarf irregular galaxy in the Local Group. The B, V, and I passband CCD images (typical seeing ∼0.''8) were obtained with the Subaru Telescope equipped with the Suprime-Cam mosaic camera. The wide-field (20' × 24') photometry catalog of 38,856 objects (V ∼ 16-26 mag) is presented. This survey is also intended to serve as ''a finding chart'' for future imaging and spectroscopic observation programs of Leo A.

  6. Far ultraviolet wide field imaging with a SPARTAN /Experiment of Opportunity/ Payload

    NASA Technical Reports Server (NTRS)

    Carruthers, G. R.; Heckathorn, H. M.; Opal, C. B.

    1982-01-01

    A wide-field electrographic Schmidt camera, sensitive in the far UV (1230-2000 A), has been developed and utilized in three sounding rocket flights. It is now being prepared for Shuttle flight as an Experiment of Opportunity Payload (EOP) (recently renamed as the SPARTAN program). In this paper, we discuss (1) design of the instrument and payload, particularly as influenced by our experience in rocket flights; (2) special problems of EOP in comparison to sounding rocket missions; (3) relationship of this experiment to, and special capabilities in comparison to, other space astronomy instruments such as Space Telescope; and (4) a tentative observing plan for an EOP mission.

  7. Far ultraviolet wide field imaging and photometry - Spartan-202 Mark II Far Ultraviolet Camera

    NASA Technical Reports Server (NTRS)

    Carruthers, George R.; Heckathorn, Harry M.; Opal, Chet B.; Witt, Adolf N.; Henize, Karl G.

    1988-01-01

    The U.S. Naval Research Laboratory' Mark II Far Ultraviolet Camera, which is expected to be a primary scientific instrument aboard the Spartan-202 Space Shuttle mission, is described. This camera is intended to obtain FUV wide-field imagery of stars and extended celestial objects, including diffuse nebulae and nearby galaxies. The observations will support the HST by providing FUV photometry of calibration objects. The Mark II camera is an electrographic Schmidt camera with an aperture of 15 cm, a focal length of 30.5 cm, and sensitivity in the 1230-1600 A wavelength range.

  8. Estimating the Supernova Cosmological Constraints Possible With the Wide-Field Infrared Survey Telescope

    NASA Astrophysics Data System (ADS)

    Currie, Miles; Rubin, David; Aldering, Greg Scott; Baltay, Charles; Fagrelius, Parker; Law, David R.; Perlmutter, Saul; Pontoppidan, Klaus

    2016-01-01

    The proposed Wide-Field Infrared Survey Telescope (WFIRST) supernova survey will measure precision distances continuously in redshift to 1.7 with excellent systematics control. However, the Science Definition Team report presented a idealized version of the survey, and we now work to add realism. Using SNe from HST programs, we investigate the expected contamination from the host-galaxy light to estimate required exposure times. We also present estimates of purity and completeness, generated by degrading well-measured nearby SN spectra to WFIRST resolution and signal-to-noise. We conclude with a more accurate prediction of the cosmological constraints possible with WFIRST SNe.

  9. Real-time monitoring of graphene patterning with wide-field four-wave mixing microscopy

    NASA Astrophysics Data System (ADS)

    Koivistoinen, Juha; Aumanen, Jukka; Hiltunen, Vesa-Matti; Myllyperkiö, Pasi; Johansson, Andreas; Pettersson, Mika

    2016-04-01

    The single atom thick two-dimensional graphene is a promising material for various applications due to its extraordinary electronic, optical, optoelectronic, and mechanical properties. The demand for developing graphene based applications has entailed a requirement for development of methods for fast imaging techniques for graphene. Here, we demonstrate imaging of graphene with femtosecond wide-field four-wave mixing microscopy. The method provides a sensitive, non-destructive approach for rapid large area characterization of graphene. We show that the method is suitable for online following of a laser patterning process of microscale structures on single-layer graphene.

  10. Developments of wide field submillimeter optics and lens antenna-coupled MKID cameras

    NASA Astrophysics Data System (ADS)

    Sekimoto, Y.; Nitta, T.; Karatsu, K.; Sekine, M.; Sekiguchi, S.; Okada, T.; Shu, S.; Noguchi, T.; Naruse, M.; Mitsui, K.; Okada, N.; Tsuzuki, T.; Dominjon, A.; Matsuo, H.

    2014-07-01

    Wide field cryogenic optics and millimeter-wave Microwave Kinetic Inductance Detector (MKID) cameras with Si lens array have been developed. MKID is a Cooper-pair breaking photon detector and consists of supercon- ducting resonators which enable microwave (~GHz) frequency multiplexing. Antenna-coupled Aluminum CPW resonators are put in a line on a Si substrate to be read by a pair of coaxial cables. A 220 GHz - 600 pixels MKID camera with anti-reflection (AR) coated Si lens has been demonstrated in an 0.1 K cryostat. A compact cryogenic system with high refractive index materials has been developed for the MKID camera.

  11. The First Hundred Brown Dwarfs Discovered by the Wide-Field Infrared Survey Explorer (WISE)

    NASA Technical Reports Server (NTRS)

    Kirkpatrick, J. Davy; Cushing, Michael C.; Gelino, Christopher R.; Griffith, Roger L.; Skrutskie, Michael F.; Marsh, Kenneth A.; Wright, Edward L.; Mainzer, Amanda K.; Eisenhardt, Peter R.; McLean, Ian S.; Bauer, James M.; Benford, Dominic J.; Lake, Sean E.; Petty, Sara M.; Tsai, Chao-Wei; Beichman, Charles; Stapelfeldt, Karl R.; Stern, Daniel; Vacca, William D.

    2011-01-01

    We present ground-based spectroscopic verification of six Y dwarfs also Cushing et al.), eighty-nine T dwarfs, eight L dwarfs, and one M dwarf identified by the Wide-field Infrared Survey Explorer (WISE). Eighty of these are cold brown dwarfs with spectral types > or =T6, six of which have been announced earlier in Mainzer et al. and I3urgasser et al. We present color-color and colortype diagrams showing the locus of M, L, T, and Y dwarfs in WISE color space. "

  12. On the Design of Wide-Field X-ray Telescopes

    NASA Technical Reports Server (NTRS)

    Elsner, Ronald F.; O'Dell, Stephen L.; Ramsey, Brian D.; Weiskopf, Martin C.

    2009-01-01

    X-ray telescopes having a relatively wide field-of-view and spatial resolution vs. polar off-axis angle curves much flatter than the parabolic dependence characteristic of Wolter I designs are of great interest for surveys of the X-ray sky and potentially for study of the Sun s X-ray emission. We discuss the various considerations affecting the design of such telescopes, including the possible use of polynomial mirror surface prescriptions, a method of optimizing the polynomial coefficients, scaling laws for mirror segment length vs. intersection radius, the loss of on-axis spatial resolution, and the positioning of focal plane detectors.

  13. Wide-field compact catadioptric telescope spanning 0.7-14 μm wavelengths.

    PubMed

    Marks, Daniel L; Hagen, Nathan; Durham, Mark; Brady, David J

    2013-06-20

    We present a wide-field compact f-1.2, f-1.6 effective illumination catadioptric telescope that spans the wavelengths 0.7-14.0 μm. Such a telescope replaces several telescopes designed for different infrared bands, while having a track length shorter than most single-band telescopes. Incorporated with a suitable multiband focal plane array, many wavelength bands may be imaged simultaneously in the same instrument. We have constructed and tested prototypes of the telescopes and found the performance is near the predicted values. PMID:23842177

  14. Wide Field Camera 3: A Powerful New Imager for the Hubble Space Telescope

    NASA Technical Reports Server (NTRS)

    Kimble, Randy

    2008-01-01

    Wide Field Camera 3 (WFC3) is a powerful UV/visible/near-infrared camera in development for installation into the Hubble Space Telescope during upcoming Servicing Mission 4. WFC3 provides two imaging channels. The UVIS channel incorporates a 4096 x 4096 pixel CCD focal plane with sensitivity from 200 to 1000 nm. The IR channel features a 1024 x 1024 pixel HgCdTe focal plane covering 850 to 1700 nm. We report here on the design of the instrument, the performance of its flight detectors, results of the ground test and calibration program, and the plans for the Servicing Mission installation and checkout.

  15. The NOAO Deep Wide-Field Survey Image Cutout Web Service

    NASA Astrophysics Data System (ADS)

    Davis, Lindsey E.; Fitzpatrick, Mike; Tody, Doug

    A Web service for extracting multi-band science grade image cutouts from the NOAO Deep Wide-Field Survey (NDWFS) is described. The NDWFS data is stored as a multi-band database of large images on the NDWFS archive server. Given a cutout center and size the NDWFS image cutout service creates cutout images on-the-fly. The service provides high performance access to the survey data and isolates the client from the details of how the survey data is stored in the archive.

  16. Linearity of the Faraday-rotation-type ac magnetic-field sensor with a ferrimagnetic or ferromagnetic rotator film

    NASA Astrophysics Data System (ADS)

    Mori, Hiroshi; Asahara, Yousuke

    1996-03-01

    We analyze the linearity and modulation depth of ac magnetic-field sensors or current sensors, using a ferrimagnetic or ferromagnetic film as the Faraday rotator and employing the detection of only the zeroth-order optical diffraction component from the rotator. It is theoretically shown that for this class of sensor the condition of a constant modulation depth and that of a constant ratio error give an identical series of curves for the relationship between Faraday rotation angle greater than or equals V and polarizer/analyzer relative angle Phi . We give some numerical examples to demonstrate the usefulness of the result with reference to a rare-earth iron garnet film as the rotator.

  17. A wide field-of-view scanning endoscope for whole anal canal imaging.

    PubMed

    Han, Chao; Huangfu, Jiangtao; Lai, Lily L; Yang, Changhuei

    2015-02-01

    We report a novel wide field-of-view (FOV) scanning endoscope, the AnCam, which is based on contact image sensor (CIS) technology used in commercialized business card scanners. The AnCam can capture the whole image of the anal canal within 10 seconds with a resolution of 89 μm, a maximum FOV of 100 mm × 120 mm, and a depth-of-field (DOF) of 0.65 mm at 5.9 line pairs per mm (lp/mm). We demonstrate the performance of the AnCam by imaging the entire anal canal of pigs and tracking the dynamics of acetowhite testing. We believe the AnCam can potentially be a simple and convenient solution for screening of the anal canal for dysplasia and for surveillance in patients following treatment for anal cancer. PMID:25780750

  18. Stellar photometry with the Hubble Space Telescope Wide-field/Planetary camera - A progress report

    NASA Technical Reports Server (NTRS)

    Holtzman, Jon A.; Hunter, Deidre; Groth, Edward J.; Light, Robert M.; Faber, S. M.

    1991-01-01

    The prospects for the use of the Wide-Field/Planetary Camera (WFPC) for stellar photometry are described. The large halos of the point-spread function (PSF) resulting from spherical aberration and from spatial, temporal, and color variations of the PSF are the main limitations to accurate photometry. Degradations caused by crowding are exacerbated by the halos of the PSF. An attempt is made to quantify these effects and determine the current accuracy of stellar photometry with the WFPC. In realistic cases, the brighter stars in crowded fields have 0.09 mag errors; fainter stars have larger errors depending on the degree of crowding. It is shown that measuring Cepheids in Virgo Cluster galaxies is not currently possible without inordinate increases in exposure times.

  19. Developing Wide-Field Spatio-Spectral Interferometry for Far-Infrared Space Applications

    NASA Technical Reports Server (NTRS)

    Leisawitz, David; Bolcar, Matthew R.; Lyon, Richard G.; Maher, Stephen F.; Memarsadeghi, Nargess; Rinehart, Stephen A.; Sinukoff, Evan J.

    2012-01-01

    Interferometry is an affordable way to bring the benefits of high resolution to space far-IR astrophysics. We summarize an ongoing effort to develop and learn the practical limitations of an interferometric technique that will enable the acquisition of high-resolution far-IR integral field spectroscopic data with a single instrument in a future space-based interferometer. This technique was central to the Space Infrared Interferometric Telescope (SPIRIT) and Submillimeter Probe of the Evolution of Cosmic Structure (SPECS) space mission design concepts, and it will first be used on the Balloon Experimental Twin Telescope for Infrared Interferometry (BETTII). Our experimental approach combines data from a laboratory optical interferometer (the Wide-field Imaging Interferometry Testbed, WIIT), computational optical system modeling, and spatio-spectral synthesis algorithm development. We summarize recent experimental results and future plans.

  20. Wide-field endoscopic fluorescence imaging for gastrointestinal tumor detection with glucose analogue

    NASA Astrophysics Data System (ADS)

    He, Yun; Qu, Yawei; Bai, Jing; Liu, Haifeng

    2014-05-01

    The lack of functional information and targeted imaging in conventional white-light endoscopy leads to a high miss-rate of gastrointestinal tumor. The combination of near-infrared fluorescence imaging and endoscopy presents a promising approach. Here we introduce a new endoscopy method employing a home-made flexible wide-field epi-fluorescence endoscope, that can be inserted through the biopsy channel of a gastrointestinal endoscope, with the glucose analogue 2- DeoxyGlucosone as the near-infrared fluorescent probe. System characterization indicates a good sensitivity and linearity over a large field of view. Its capability of tumor identification and location is demonstrated with in-vivo imaging of xenografted tumor model.

  1. Continuous wide-field characterization of drug release from skin substitute using off-axis interferometry.

    PubMed

    Gabai, Haniel; Baranes-Zeevi, Maya; Zilberman, Meital; Shaked, Natan T

    2013-08-15

    We achieved continuous, noncontact wide-field imaging and characterization of drug release from a polymeric device in vitro by uniquely using off-axis interferometric imaging. Unlike the current gold-standard methods in this field, which are usually based on chromatography and spectroscopy, our method requires no user intervention during the experiment and involves less lab consumable instruments. Using a simplified interferometric imaging system, we experimentally demonstrate the characterization of anesthetic drug release (Bupivacaine) from a soy-based protein matrix, which is used as a skin substitute for wound dressing. Our results demonstrate the potential of interferometric imaging as an inexpensive and easy-to-use alternative for characterization of drug release in vitro. PMID:24104636

  2. A wide field-of-view scanning endoscope for whole anal canal imaging

    PubMed Central

    Han, Chao; Huangfu, Jiangtao; Lai, Lily L.; Yang, Changhuei

    2015-01-01

    We report a novel wide field-of-view (FOV) scanning endoscope, the AnCam, which is based on contact image sensor (CIS) technology used in commercialized business card scanners. The AnCam can capture the whole image of the anal canal within 10 seconds with a resolution of 89 μm, a maximum FOV of 100 mm × 120 mm, and a depth-of-field (DOF) of 0.65 mm at 5.9 line pairs per mm (lp/mm). We demonstrate the performance of the AnCam by imaging the entire anal canal of pigs and tracking the dynamics of acetowhite testing. We believe the AnCam can potentially be a simple and convenient solution for screening of the anal canal for dysplasia and for surveillance in patients following treatment for anal cancer. PMID:25780750

  3. OP09O-OP404-9 Wide Field Camera 3 CCD Quantum Efficiency Hysteresis

    NASA Technical Reports Server (NTRS)

    Collins, Nick

    2009-01-01

    The HST/Wide Field Camera (WFC) 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. At the nominal operating temperature of -83C, the QEH feature contrast was typically 0.1-0.2% or less. The behavior was replicated using flight spare detectors. A visible light flat-field (540nm) with a several times full-well signal level can pin the detectors at both optical (600nm) and near-UV (230nm) wavelengths, suppressing the QEH behavior. We are characterizing the timescale for the detectors to become unpinned and developing a protocol for flashing the WFC3 CCDs with the instrument's internal calibration system in flight. The HST/Wide Field Camera 3 UV/visible channel CCD detectors have exhibited an unanticipated quantum efficiency hysteresis (QEH) behavior. The first observed manifestation of QEH was the presence in a small percentage of flat-field images of a bowtie-shaped contrast that spanned the width of each chip. At the nominal operating temperature of -83C, the contrast observed for this feature was typically 0.1-0.2% or less, though at warmer temperatures contrasts up to 5% (at -50C) have been observed. The bowtie morphology was replicated using flight spare detectors in tests at the GSFC Detector Characterization Laboratory by power cycling the detector while cold. Continued investigation revealed that a clearly-related global QE suppression at the approximately 5% level can be produced by cooling the detector in the dark; subsequent flat-field exposures at a constant illumination show asymptotically increasing response. This QE "pinning" can be achieved with a single high signal flat-field or a series of lower signal flats; a visible light (500-580nm) flat-field with a signal level of several hundred thousand electrons per pixel is sufficient for QE pinning at both optical (600nm) and near-UV (230nm) wavelengths. We are characterizing the timescale for the detectors to become unpinned and developing a

  4. Integration of wide field-of-view imagery functions in a detector dewar cooler assembly

    NASA Astrophysics Data System (ADS)

    Druart, Guillaume; de la Barriere, Florence; Guerineau, Nicolas; Lasfargues, Gilles; Fendler, Manuel; Lhermet, Nicolas; Taboury, Jean; Reibel, Yann; Moullec, Jean-Baptiste

    2012-06-01

    Today, both military and civilian applications require miniaturized optical systems in order to give an imagery function to vehicles with small payload capacity. After the development of megapixel focal plane arrays (FPA) with micro-sized pixels, this miniaturization will become feasible with the integration of optical functions in the detector area. In the field of cooled infrared imaging systems, the detector area is the Detector-Dewar-Cooler Assembly (DDCA). A dewar is a sealed environment where the detector is cooled on a cold plate. We show in this paper that wide field of view imagery functions can be simply added to the dewar. We investigate two ways of integration and make two demonstrators. The first one called FISBI consists in replacing the window by a fish-eye lens and in integrating a lens in the cold shield. This optical system has a field of view of 180°. The second one, called IR-Cam-on-Chip, consists in integrating the optics directly on the focal plane array. This optical system has a field of view of 120°. The additional mass of the optics is sufficiently small to be compatible with the cryogenic environment of the DDCA. The performance of these cameras will be discussed and several evolutions of these cameras will be introduced too.

  5. Wide Field Collimator 2 (WFC2) for GOES Imager and Sounder

    NASA Technical Reports Server (NTRS)

    Etemad, Shahriar; Bremer, James C.; Zukowski, Barbara J.; Pasquale, Bert A.; zukowski, Tmitri J.; Prince, Robert E.; O'Neill, Patrick A.; Ross, Robert W.

    2004-01-01

    Two of the GOES instruments, the Imager and the Sounder, perform scans of the Earth to provide a full disc picture of the Earth. To verify the entire scan process, an image of a target that covers an 18 deg. circular field-of-view is collimated and projected into the field of regard of each instrument. The Wide Field Collimator 2 (WFC2) has many advantages over its predecessor, WFC1, including lower thermal dissipation higher fir field MTF, smaller package, and a more intuitive (faster) focusing process. The illumination source is an LED array that emits in a narrow spectral band centered at 689 nm, within the visible spectral bands of the Imager and Sounder. The illumination level can be continuously adjusted electronically. Lower thermal dissipation eliminates the need for forced convection cooling and minimizes time to reach thermal stability. The lens system has been optimized for the illumination source spectral output and athernalized to remain in focus during bulk temperature changes within the laboratory environment. The MTF of the lens is higher than that of the WFC1 at the edge of FOV. The target is focused in three orthogonal motions, controlled by an ergonomic system that saves substantial time and produces a sharper focus. Key words: Collimator, GOES, Imager, Sounder, Projector

  6. Enhanced signal coupling in wide-field fiber-coupled imagers.

    PubMed

    Arianpour, Ashkan; Motamedi, Nojan; Agurok, Ilya P; Ford, Joseph E

    2015-02-23

    Some high-performance imaging systems, including wide angle "monocentric" lenses made of concentric spherical shells, form a deeply curved image surface coupled to focal plane sensors by optical fiber bundles with a curved input and flat output face. However, refraction at the angled input facet limits the range of input angles, even for fiber bundles with numerical aperture 1. Here we investigate using a curved beam deflector near the focal surface to increase the field of view and improve spatial resolution at the edges of the field of view. We show the field of view of such an imager can be increased from approximately 60° (full width at half maximum intensity) to over 90° using an embossed refractive microprism array, where the prism angle varies across the aperture to maintain coupling. We describe a proof-of-principle experiment using a f = 17.8mm fiber-coupled monocentric singlet lens, and show that a local region of microprisms embossed into a thin layer of SU-8 photopolymer can increase the field of view by 50%. PMID:25836560

  7. Electrolocation-based underwater obstacle avoidance using wide-field integration methods.

    PubMed

    Dimble, Kedar D; Faddy, James M; Humbert, J Sean

    2014-03-01

    Weakly electric fish are capable of efficiently performing obstacle avoidance in dark and navigationally challenging aquatic environments using electrosensory information. This sensory modality enables extraction of relevant proximity information about surrounding obstacles by interpretation of perturbations induced to the fish's self-generated electric field. In this paper, reflexive obstacle avoidance is demonstrated by extracting relative proximity information using spatial decompositions of the perturbation signal, also called an electric image. Electrostatics equations were formulated for mathematically expressing electric images due to a straight tunnel to the electric field generated with a planar electro-sensor model. These equations were further used to design a wide-field integration based static output feedback controller. The controller was implemented in quasi-static simulations for environments with complicated geometries modelled using finite element methods to demonstrate sense and avoid behaviours. The simulation results were confirmed by performing experiments using a computer operated gantry system in environments lined with either conductive or non-conductive objects acting as global stimuli to the field of the electro-sensor. The proposed approach is computationally inexpensive and readily implementable, making underwater autonomous navigation in real-time feasible. PMID:24451219

  8. Field and long-term demonstration of a wide area quantum key distribution network.

    PubMed

    Wang, Shuang; Chen, Wei; Yin, Zhen-Qiang; Li, Hong-Wei; He, De-Yong; Li, Yu-Hu; Zhou, Zheng; Song, Xiao-Tian; Li, Fang-Yi; Wang, Dong; Chen, Hua; Han, Yun-Guang; Huang, Jing-Zheng; Guo, Jun-Fu; Hao, Peng-Lei; Li, Mo; Zhang, Chun-Mei; Liu, Dong; Liang, Wen-Ye; Miao, Chun-Hua; Wu, Ping; Guo, Guang-Can; Han, Zheng-Fu

    2014-09-01

    A wide area quantum key distribution (QKD) network deployed on communication infrastructures provided by China Mobile Ltd. is demonstrated. Three cities and two metropolitan area QKD networks were linked up to form the Hefei-Chaohu-Wuhu wide area QKD network with over 150 kilometers coverage area, in which Hefei metropolitan area QKD network was a typical full-mesh core network to offer all-to-all interconnections, and Wuhu metropolitan area QKD network was a representative quantum access network with point-to-multipoint configuration. The whole wide area QKD network ran for more than 5000 hours, from 21 December 2011 to 19 July 2012, and part of the network stopped until last December. To adapt to the complex and volatile field environment, the Faraday-Michelson QKD system with several stability measures was adopted when we designed QKD devices. Through standardized design of QKD devices, resolution of symmetry problem of QKD devices, and seamless switching in dynamic QKD network, we realized the effective integration between point-to-point QKD techniques and networking schemes. PMID:25321550

  9. A novel genome-wide polyadenylation sites recognition system based on condition random field.

    PubMed

    Han, Jiuqiang; Zhang, Shanxin; Liu, Jun; Liu, Ruiling

    2014-01-01

    Polyadenylation including the cleavage of pre-mRNA and addition of a stretch of adenosines to the 3'-end is an essential step of pre-mRNA processing in eukayotes. The known regulatory role of polyadenylation in mRNA localization, stability, and translation and the emerging link between poly(A) and disease states underline the necessary to fully characterize polyadenylation sites. Several artificial intelligence methods have been proposed for poly(A) sites recognition. However, these methods are suitable to small subsets of genome sequences. It is necessary to propose a method for genome-wide recognition of poly(A) sites. Recent efforts have found a lot of poly(A) related factors on DNA level. Here, we proposed a novel genome-wide poly(A) recognition method based on the Condition Random Field (CRF) by integrating multiple features. Compared with the polya_svm (the most accurate program for prediction of poly(A) sites till date), our method had a higher performance with the area under ROC curve(0.8621 versus 0.6796). The result suggests that our method is an effective method in genome wide poly(A) sites recognition. PMID:25571055

  10. Fast multicamera video stitching for underwater wide field-of-view observation

    NASA Astrophysics Data System (ADS)

    Li, Qing-Zhong; Zhang, Yang; Zang, Feng-Ni

    2014-03-01

    Underwater robots equipped with a single forward-looking camera usually have a very limited visual range or field-of-view (FOV) due to the light absorption and scattering effects in the underwater environment, which greatly limit their applications for underwater video-based inspection, navigation, and so on. Although underwater robots using multicamera imaging systems can achieve wide FOV of surroundings, parallax distortion and time-consuming stitching computation are encountered, especially for short-distance observation. To overcome these problems, we present a fast multicamera video-stitching algorithm based on adaptive adjustment of image transformation matrix between adjacent images. The proposed method uses a fast and adaptive optimization algorithm to search the optimal parameters of transformation matrix that can minimize the parallax distortion due to short-distance imaging and maximize the matching degree between adjacent overlapping image areas. The advantage of the proposed stitching method lies in that it avoids the complex and time-consuming computations for feature-point extraction and matching. The experimental results show that the proposed method can construct multicamera-based wide FOV video effectively and meets the real-time requirement of wide FOV video observation for both indoor and underwater scenes.

  11. Wide-field computational color imaging using pixel super-resolved on-chip microscopy

    PubMed Central

    Greenbaum, Alon; Feizi, Alborz; Akbari, Najva; Ozcan, Aydogan

    2013-01-01

    Lens-free holographic on-chip imaging is an emerging approach that offers both wide field-of-view (FOV) and high spatial resolution in a cost-effective and compact design using source shifting based pixel super-resolution. However, color imaging has remained relatively immature for lens-free on-chip imaging, since a ‘rainbow’ like color artifact appears in reconstructed holographic images. To provide a solution for pixel super-resolved color imaging on a chip, here we introduce and compare the performances of two computational methods based on (1) YUV color space averaging, and (2) Dijkstra’s shortest path, both of which eliminate color artifacts in reconstructed images, without compromising the spatial resolution or the wide FOV of lens-free on-chip microscopes. To demonstrate the potential of this lens-free color microscope we imaged stained Papanicolaou (Pap) smears over a wide FOV of ~14 mm2 with sub-micron spatial resolution. PMID:23736466

  12. Identification of boundaries in the cometary environment from AC electric field measurements

    NASA Astrophysics Data System (ADS)

    Mogilevsky, M.; Mikhailov, Y.; Molchanov, O.; Grard, R.; Pedersen, A.; Trotignon, J. G.; Beghin, C.; Formisano, V.; Shapiro, V.; Shevchenko, V.

    1986-12-01

    Electric fields are measured with the AVP-V experiment in the frequency range 8 Hz - 300 kHz. The field amplitude increases significantly, first at a distance of 2×105km, then at distances of 1.2 - 1.5×105km, and 5 - 7×104km from the nucleus. These phenomena have been observed both on VEGA-1 and VEGA-2. The electric field measurements are compared with data obtained from dust and plasma experiments; possible mechanisms responsible for the existence of these boundaries are discussed.

  13. Wide-Field InfraRed Survey Telescope (WFIRST) Slitless Spectrometer: Design, Prototype, and Results

    NASA Technical Reports Server (NTRS)

    Gong, Qian; Content, David; Dominguez, Margaret; Emmett, Thomas; Griesmann, Ulf; Hagopian, John; Kruk, Jeffrey; Marx, Catherine; Pasquale, Bert; Wallace, Thomas; Whipple, Arthur

    2016-01-01

    The slitless spectrometer plays an important role in the Wide-Field InfraRed Survey Telescope (WFIRST) mission for the survey of emission-line galaxies. This will be an unprecedented very wide field, HST quality 3D survey of emission line galaxies. The concept of the compound grism as a slitless spectrometer has been presented previously. The presentation briefly discusses the challenges and solutions of the optical design, and recent specification updates, as well as a brief comparison between the prototype and the latest design. However, the emphasis of this paper is the progress of the grism prototype: the fabrication and test of the complicated diffractive optical elements and powered prism, as well as grism assembly alignment and testing. Especially how to use different tools and methods, such as IR phase shift and wavelength shift interferometry, to complete the element and assembly tests. The paper also presents very encouraging results from recent element tests to assembly tests. Finally we briefly touch the path forward plan to test the spectral characteristic, such as spectral resolution and response.

  14. WSCLEAN: an implementation of a fast, generic wide-field imager for radio astronomy

    NASA Astrophysics Data System (ADS)

    Offringa, A. R.; McKinley, B.; Hurley-Walker, N.; Briggs, F. H.; Wayth, R. B.; Kaplan, D. L.; Bell, M. E.; Feng, L.; Neben, A. R.; Hughes, J. D.; Rhee, J.; Murphy, T.; Bhat, N. D. R.; Bernardi, G.; Bowman, J. D.; Cappallo, R. J.; Corey, B. E.; Deshpande, A. A.; Emrich, D.; Ewall-Wice, A.; Gaensler, B. M.; Goeke, R.; Greenhill, L. J.; Hazelton, B. J.; Hindson, L.; Johnston-Hollitt, M.; Jacobs, D. C.; Kasper, J. C.; Kratzenberg, E.; Lenc, E.; Lonsdale, C. J.; Lynch, M. J.; McWhirter, S. R.; Mitchell, D. A.; Morales, M. F.; Morgan, E.; Kudryavtseva, N.; Oberoi, D.; Ord, S. M.; Pindor, B.; Procopio, P.; Prabu, T.; Riding, J.; Roshi, D. A.; Shankar, N. Udaya; Srivani, K. S.; Subrahmanyan, R.; Tingay, S. J.; Waterson, M.; Webster, R. L.; Whitney, A. R.; Williams, A.; Williams, C. L.

    2014-10-01

    Astronomical wide-field imaging of interferometric radio data is computationally expensive, especially for the large data volumes created by modern non-coplanar many-element arrays. We present a new wide-field interferometric imager that uses the w-stacking algorithm and can make use of the w-snapshot algorithm. The performance dependences of CASA's w-projection and our new imager are analysed and analytical functions are derived that describe the required computing cost for both imagers. On data from the Murchison Widefield Array, we find our new method to be an order of magnitude faster than w-projection, as well as being capable of full-sky imaging at full resolution and with correct polarization correction. We predict the computing costs for several other arrays and estimate that our imager is a factor of 2-12 faster, depending on the array configuration. We estimate the computing cost for imaging the low-frequency Square Kilometre Array observations to be 60 PetaFLOPS with current techniques. We find that combining w-stacking with the w-snapshot algorithm does not significantly improve computing requirements over pure w-stacking. The source code of our new imager is publicly released.

  15. Experimental comparison of Wide Field AO control schemes using the Homer AO bench.

    NASA Astrophysics Data System (ADS)

    Parisot, Amélie; Petit, Cyril; Fusco, Thierry

    2011-09-01

    Wide Field Adaptive Optics (WFAO) concepts, such as Laser Tomography AO (LTAO) or Multi-Conjugate AO (MCAO) have been developed in order to overcome the anisoplanatism limit of classical AO. Most of the future AO-assisted instruments of ELTs rely on such concepts which have raised critical challenges such as tomographic estimation and from laser and natural guide star combined with efficient DM(s) control. In that context, the experimental validation of the various clever control solutions proposed by several teams in the past years is now essential to reach a level of maturity compatible with their implementation in future WFAO developments for ELT. The ONERA wide field AO facility (HOMER bench) has been developed for these very issues. Gathering a 3D turbulence generator, laser and natural guide stars, two deformable mirrors with variable altitude positions and a PC-based flexible and user-friendly RTC , HOMER allows the implementation and comparison of control schemes from the simplest least-square to the optimal Linear Quadratic Gaussian solutions including Virtual DM and Pseudo-closed loop approaches. After a description of the bench internal calibrations and ultimate performance, all the control schemes are compared experimentally. Their evolutions as a function of wavefront sensors SNR as well as their robustness to calibration / model errors are particularly emphasised. Finally, we derive from the previous works some specific calibrations and identifications procedures ensuring both robustness and efficiency of WFAO systems and we extrapolate their applications to the future ELT AO systems.

  16. Wide-field medium-repetition-rate multiphoton microscopy reduces photodamage of living cells.

    PubMed

    Macias-Romero, C; Zubkovs, V; Wang, S; Roke, S

    2016-04-01

    Demands of higher spatial and temporal resolutions in linear and nonlinear imaging keep pushing the limits of optical microscopy. We showed recently that a multiphoton microscope with 200 kHz repetition rate and wide-field illumination has a 2-3 orders of magnitude improved throughput compared to a high repetition rate confocal scanning microscope. Here, we examine the photodamage mechanisms and thresholds in live cell imaging for both systems. We first analyze theoretically the temperature increase in an aqueous solution resulting from illuminating with different repetition rates (keeping the deposited energy and irradiated volume constant). The analysis is complemented with photobleaching experiments of a phenolsulfonphthalein (phenol red) solution. Combining medium repetition rates and wide-field illumination promotes thermal diffusivity, which leads to lower photodamage and allows for higher peak intensities. A three day proliferation assay is also performed on living cells to confirm these results: dwell times can be increased by a factor of 3×10(6) while still preserving cell proliferation. By comparing the proliferation data with the endogenous two-photon fluorescence decay, we propose to use the percentage of the remaining endogenous two-photon fluorescence after exposure as a simple in-situ viability test. These findings enable the possibility of long-term imaging and reduced photodamage. PMID:27446668

  17. Wide-field medium-repetition-rate multiphoton microscopy reduces photodamage of living cells

    PubMed Central

    Macias-Romero, C.; Zubkovs, V.; Wang, S.; Roke, S.

    2016-01-01

    Demands of higher spatial and temporal resolutions in linear and nonlinear imaging keep pushing the limits of optical microscopy. We showed recently that a multiphoton microscope with 200 kHz repetition rate and wide-field illumination has a 2–3 orders of magnitude improved throughput compared to a high repetition rate confocal scanning microscope. Here, we examine the photodamage mechanisms and thresholds in live cell imaging for both systems. We first analyze theoretically the temperature increase in an aqueous solution resulting from illuminating with different repetition rates (keeping the deposited energy and irradiated volume constant). The analysis is complemented with photobleaching experiments of a phenolsulfonphthalein (phenol red) solution. Combining medium repetition rates and wide-field illumination promotes thermal diffusivity, which leads to lower photodamage and allows for higher peak intensities. A three day proliferation assay is also performed on living cells to confirm these results: dwell times can be increased by a factor of 3×106 while still preserving cell proliferation. By comparing the proliferation data with the endogenous two-photon fluorescence decay, we propose to use the percentage of the remaining endogenous two-photon fluorescence after exposure as a simple in-situ viability test. These findings enable the possibility of long-term imaging and reduced photodamage.

  18. Wide-field profiling of smooth steep surfaces by structured illumination

    NASA Astrophysics Data System (ADS)

    Wang, Hongting; Tan, Jiubin; Liu, Chenguang; Liu, Jian; Li, Yong

    2016-05-01

    We propose sectioning structured illumination wide-field microscopy (SSIWM) combined with the coating of a readily removable thin fluorescent film (RTFF) for smooth steep surfaces. The profiling of smooth steep surfaces is difficult to achieve using conventional optical systems because these surfaces reflect lights away from the collective lens. In particular, when the angle between optical axis and the normal line of the surface is larger than sin-1(NA), no light reflected from the area can be collected by the collective lens. The proposed method employing an RTFF to the SSIWM can overcome the poor collection barrier and be used to measure the shape of the surface owing to the isotropic incoherent scattering property. Additionally, conventional SSIWM is a promising wide-field imaging technique with high axial sectioning ability and low cost; however, it cannot be introduced to measure a reflective surface because of the non-sectioning characteristic in using a laser (coherent). However, the proposed method can extend the application scope of SSIWM owing to the incoherent property of the coating surface. Simulations and experimental results are presented to show the validity of the proposed method.

  19. Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

    NASA Technical Reports Server (NTRS)

    Fazio, Giovanni G.

    1988-01-01

    The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

  20. Generalized mesh-based Monte Carlo for wide-field illumination and detection via mesh retessellation

    PubMed Central

    Yao, Ruoyang; Intes, Xavier; Fang, Qianqian

    2015-01-01

    Monte Carlo methods are commonly used as the gold standard in modeling photon transport through turbid media. With the rapid development of structured light applications, an accurate and efficient method capable of simulating arbitrary illumination patterns and complex detection schemes over large surface area is in great need. Here we report a generalized mesh-based Monte Carlo algorithm to support a variety of wide-field illumination methods, including spatial-frequency-domain imaging (SFDI) patterns and arbitrary 2-D patterns. The extended algorithm can also model wide-field detectors such as a free-space CCD camera. The significantly enhanced flexibility of source and detector modeling is achieved via a fast mesh retessellation process that combines the target domain and the source/detector space in a single tetrahedral mesh. Both simulations of complex domains and comparisons with phantom measurements are included to demonstrate the flexibility, efficiency and accuracy of the extended algorithm. Our updated open-source software is provided at http://mcx.space/mmc. PMID:26819826

  1. Using Wide-Field Meteor Cameras to Actively Engage Students in Science

    NASA Astrophysics Data System (ADS)

    Kuehn, D. M.; Scales, J. N.

    2012-08-01

    Astronomy has always afforded teachers an excellent topic to develop students' interest in science. New technology allows the opportunity to inexpensively outfit local school districts with sensitive, wide-field video cameras that can detect and track brighter meteors and other objects. While the data-collection and analysis process can be mostly automated by software, there is substantial human involvement that is necessary in the rejection of spurious detections, in performing dynamics and orbital calculations, and the rare recovery and analysis of fallen meteorites. The continuous monitoring allowed by dedicated wide-field surveillance cameras can provide students with a better understanding of the behavior of the night sky including meteors and meteor showers, stellar motion, the motion of the Sun, Moon, and planets, phases of the Moon, meteorological phenomena, etc. Additionally, some students intrigued by the possibility of UFOs and "alien visitors" may find that actual monitoring data can help them develop methods for identifying "unknown" objects. We currently have two ultra-low light-level surveillance cameras coupled to fish-eye lenses that are actively obtaining data. We have developed curricula suitable for middle or high school students in astronomy and earth science courses and are in the process of testing and revising our materials.

  2. Bilocal visual noise as a probe of wide field motion computation.

    PubMed

    Roy, Suva; de Ruyter van Steveninck, Rob

    2016-05-01

    Using an apparent visual motion stimulus with motion energies limited to specific separations in space and time, we study the computational structure of wide-field motion sensitive neurons in the fly visual brain. There is ample experimental evidence for correlation-based motion computation in many biological systems, but one of its central properties, namely that the response is proportional to the product of two bilocal signal amplitudes, remains to be tested. The design of the apparent motion stimuli used here allows us to manipulate the amplitudes of the bilocal input signals that serve as inputs to the computation. We demonstrate that the wide-field motion response of H1 and V1 neurons indeed shows bilinear behavior, even under contrast sign reversal, as predicted. But the response also varies inversely with contrast variance, an effect not described by the correlator operation. We also quantify the correlator contributions for different spatial and temporal separations. With suitable modification, the apparent motion stimuli used here can be applied to a broad range of neurophysiological as well as human psychophysical studies on motion perception. PMID:27177388

  3. Wide field OCT based microangiography in living human eye (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Zhang, Qinqin; Chen, Chieh-Li; Chu, Zhongdi; Zhang, Anqi; An, Lin; Durbin, Mary; Sharma, Utkarsh; Rosenfeld, Philip J.; Wang, Ruikang K.

    2016-03-01

    To investigate the application of optical microangiography (OMAG) in living human eye. Patients with different macular diseases were recruited, including diabetic retinopathy (DR), geographic atrophy (GA), retinitis pigmentosa (RP), and venous occlusion, et al. Wide field OCT angiography images can be generated by montage scanning protocol based on the tracking system. OMAG algorithm based on complex differentiation was used to extract the blood flow and removed the bulk motion by 2D cross-correlation method. The 3D angiography was segmented into 3 layers in the retina and 2 layers in the choroid. The en-face maximum projection was used to obtain 2-dimensional angiograms of different layers coded with different colors. Flow and structure images were combined for cross-sectional view. En face OMAG images of different macular diseases showed a great agreement with FA. Meanwhile, OMAG gave more distinct vascular network visions that were less affected by hemorrhage and leakage. The MAs were observed in both superficial and middle retinal layers based on OMAG angiograms in different layers of DR patients. The contour line of FAZ was extracted as well, which can be quantitative the retinal diseases. For GA patient, the damage of RPE layer enhanced the penetration of light and enabled the acquisition of choriocapillaries and choroidal vessels. The wide field OMAG angiogram enabled the capability of capturing the entire geographic atrophy. OMAG provides depth-resolved information and detailed vascular images of DR and GA patients, providing a better visualization of vascular network compared to FA.

  4. EXOPLANETS FROM THE ARCTIC: THE FIRST WIDE-FIELD SURVEY AT 80 Degree-Sign N

    SciTech Connect

    Law, Nicholas M.; Sivanandam, Suresh; Carlberg, Raymond; Salbi, Pegah; Ngan, Wai-Hin Wayne; Kerzendorf, Wolfgang; Ahmadi, Aida; Steinbring, Eric; Murowinski, Richard

    2013-03-15

    Located within 10 Degree-Sign of the North Pole, northern Ellesmere Island offers continuous darkness in the winter months. This capability can greatly enhance the detection efficiency of planetary transit surveys and other time domain astronomy programs. We deployed two wide-field cameras at 80 Degree-Sign N, near Eureka, Nunavut, for a 152 hr observing campaign in 2012 February. The 16 megapixel camera systems were based on commercial f/1.2 lenses with 70 mm and 42 mm apertures, and they continuously imaged 504 and 1295 deg{sup 2}, respectively. In total, the cameras took over 44,000 images and produced better than 1% precision light curves for approximately 10,000 stars. We describe a new high-speed astrometric and photometric data reduction pipeline designed for the systems, test several methods for the precision flat fielding of images from very-wide-angle cameras, and evaluate the cameras' image qualities. We achieved a scintillation-limited photometric precision of 1%-2% in each 10 s exposure. Binning the short exposures into 10 minute chunks provided a photometric stability of 2-3 mmag, sufficient for the detection of transiting exoplanets around the bright stars targeted by our survey. We estimate that the cameras, when operated over the full Arctic winter, will be capable of discovering several transiting exoplanets around bright (m{sub V} < 9.5) stars.

  5. Cone of Darkness: Finding Blank-sky Positions for Multi-object Wide-field Observations

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.

    2014-05-01

    We present the Cone of Darkness, an application to automatically configure blank-sky positions for a series of stacked, wide-field observations, such as those carried out by the SAMI instrument on the Anglo-Australian Telescope (AAT). The Sydney-AAO Multi-object Integral field spectrograph (SAMI) uses a plug-plate to mount its 13×61 core imaging fibre bundles (hexabundles) in the optical plane at the telescope's prime focus. To make the most efficient use of each plug-plate, several observing fields are typically stacked to produce a single plate. When choosing blank-sky positions for the observations it is most effective to select these such that one set of 26 holes gives valid sky positions for all fields on the plate. However, when carried out manually this selection process is tedious and includes a significant risk of error. The Cone of Darkness software aims to provide uniform blank-sky position coverage over the field of observation, within the limits set by the distribution of target positions and the chosen input catalogs. This will then facilitate the production of the best representative median sky spectrum for use in sky subtraction. The application, written in C++, is configurable, making it usable for a range of instruments. Given the plate characteristics and the positions of target holes, the software segments the unallocated space on the plate and determines the position which best fits the uniform distribution requirement. This position is checked, for each field, against the selected catalog using a TAP ADQL search. The process is then repeated until the desired number of sky positions is attained.

  6. A Class of Visual Neurons with Wide-Field Properties Is Required for Local Motion Detection.

    PubMed

    Fisher, Yvette E; Leong, Jonathan C S; Sporar, Katja; Ketkar, Madhura D; Gohl, Daryl M; Clandinin, Thomas R; Silies, Marion

    2015-12-21

    Visual motion cues are used by many animals to guide navigation across a wide range of environments. Long-standing theoretical models have made predictions about the computations that compare light signals across space and time to detect motion. Using connectomic and physiological approaches, candidate circuits that can implement various algorithmic steps have been proposed in the Drosophila visual system. These pathways connect photoreceptors, via interneurons in the lamina and the medulla, to direction-selective cells in the lobula and lobula plate. However, the functional architecture of these circuits remains incompletely understood. Here, we use a forward genetic approach to identify the medulla neuron Tm9 as critical for motion-evoked behavioral responses. Using in vivo calcium imaging combined with genetic silencing, we place Tm9 within motion-detecting circuitry. Tm9 receives functional inputs from the lamina neurons L3 and, unexpectedly, L1 and passes information onto the direction-selective T5 neuron. Whereas the morphology of Tm9 suggested that this cell would inform circuits about local points in space, we found that the Tm9 spatial receptive field is large. Thus, this circuit informs elementary motion detectors about a wide region of the visual scene. In addition, Tm9 exhibits sustained responses that provide a tonic signal about incoming light patterns. Silencing Tm9 dramatically reduces the response amplitude of T5 neurons under a broad range of different motion conditions. Thus, our data demonstrate that sustained and wide-field signals are essential for elementary motion processing. PMID:26670999

  7. Review of russian literature on biological action of DC and low-frequency AC magnetic fields.

    PubMed

    Zhadin, M N

    2001-01-01

    This review considers the Russian scientific literature on the influence of weak static and of low-frequency alternating magnetic fields on biological systems. The review covers the most interesting works and the main lines of investigation during the period 1900 to the present. Shown here are the historical roots, beginning with the ideas of V. Vernadsky and A. Chizhevsky, which led in the field of Russian biology to an increasing interest in magnetic fields, based on an intimate connection between solar activity and life on the Earth, and which determined the peculiar development of Russian magnetobiology. The variety of studies on the effects of magnetic storms and extremely low-frequency, periodic variations of the geomagnetic field on human beings and animals as well as on social phenomena are described. The diverse experiments involving artificial laboratory magnetic fields acting on different biological entities under different conditions are also considered. A series of theoretical advances are reviewed that have paved the way for a step-by-step understanding of the mechanisms of magnetic field effects on biological systems. The predominantly unfavorable influence of magnetic fields on living beings is shown, but the cases of favorable influence of magnetic fields on human beings and lower animals are demonstrated as well. The majority of Russian investigations in this area of science has been unknown among the non-Russian speaking audience for many reasons, primarily because of a language barrier. Therefore, it is hoped that this review may be of interest to the international scientific community. PMID:11122491

  8. A slowly rotating coil system for AC field measurements of Fermilab booster correctors

    SciTech Connect

    Velev, G.; DiMarco, J.; Harding, David J.; Kashikhin, V.; Lamm, Michael J.; Schlabach, P.; Tartaglia, Michael Albert; Tompkins, John C.; /Fermilab

    2007-06-01

    A method for measurement of rapidly changing magnetic fields has been developed and applied to the testing of new room temperature corrector packages designed for the Fermilab Booster Synchrotron. The method is based on fast digitization of a slowly rotating tangential coil probe, with analysis combining the measured coil voltages across a set of successive magnet current cycles. This paper presents results on the field quality measured for the normal and skew dipole, quadrupole, and sextupole elements in several of these corrector packages.

  9. Mimir: A Near-Infrared Wide-Field Imager, Spectrometer and Polarimeter

    NASA Astrophysics Data System (ADS)

    Clemens, D. P.; Sarcia, D.; Grabau, A.; Tollestrup, E. V.; Buie, M. W.; Dunham, E.; Taylor, B.

    2007-12-01

    Mimir, a new facility-class near-infrared instrument for the 1.8 m Perkins telescope on Anderson Mesa outside Flagstaff, Arizona, was commissioned and has been operating for three years. Mimir is multifunction, performing wide-field (F/5) and narrow-field (F/17) imaging, long-slit spectroscopy, and imaging polarimetry. The F/5 mode images at 0.59" per pixel onto the 1024 × 1024 pixel ALADDIN III InSb array detector, giving a 10' × 10' field of view. In the F/17 mode, the plate scale is 0.18" per pixel. Optically, Mimir is a refractive reimager for the F/17.5 Perkins beam. A six-lens collimator produces an achromatic 25 mm pupil, which is imaged by a five-lens camera (F/5), a four-lens camera (F/17), or a two-lens pupil viewer onto the detector. Three filter wheels precede the pupil, one follows the pupil. The wheels contain a rotating half-wave plate, broadband filters, narrowband filters, grisms, long-pass filters, a wire grid, and thermal IR blockers. The first telescope focus is within Mimir, where a slit and decker unit, consisting of two linear motion cars, selects one of 13 slit scenes. The slit and decker cars, the four filter wheels, the half-wave plate rotation, and the camera selector are all driven by stepper motors within the cold vacuum space. Cooling is provided by a CTI 1050 two-stage, closed-cycle helium refrigerator, keeping the optics, filters, and internal surfaces between 65 and 75 K and the detector at 33.5 K. Switching between Mimir's different modes takes only a few seconds, making it a versatile tool for conducting a wide range of investigations and for quickly reacting to changing observing conditions. Mimir on the Perkins telescope achieves imaging sensitivities 2-4 mag deeper than 2MASS, moderate resolution (R ˜ 700) JHK spectra of virtually any 2MASS source, high-precision wide-field imaging polarimetry, and L' and M' band imaging and spectroscopy.

  10. A Very Wide-Field Hybrid (Focusing/Coded Mask) X-Ray Telescope Concept

    NASA Astrophysics Data System (ADS)

    Gorenstein, Paul

    2011-09-01

    The success of Swift at detecting and positioning variable hard X-ray sources, most notably gamma-ray bursts (GRBs), demonstrates that investigations with a very wide field telescope should continue permanently, like the continuing search for supernovas, and its scope expanded. The softer X-ray band is likely to be an even richer arena in which to search for ever more distant GRBs. The X-ray component of their spectra will be enriched by the redshift especially at large distances where the redshift increases very rapidly with distance. Furthermore most GRBs are likely to have an X-ray afterglow, which a very wide field telescope would detect from its birth. Multiple X-ray afterglows can be studied simultaneously. Some GRB models predict that X-ray afterglows will be more numerous than GRBs because they are less narrowly beamed. In addition many other types of variable X-ray sources can be monitored even more effectively than by scanning instruments. There are three possible approaches to a very wide field X-ray telescope, a 2D coded mask like Swift, a 2D lobster-eye telescope, and a hybrid that is a lobster-eye telescope in one dimension and a coded mask in the other. For the same field of view and the same focal length all three could use the same detector system including an omni-directional gamma-ray detector. We offer reasons why the hybrid, which is composed of identical flat mirrors, is the best of the three. It has much less background from diffuse X-rays and known X-ray sources than the 2D coded mask, and has substantially more area and bandwidth than the 2D lobster-eye. While positions are expected to be an arc minute or better, a small number of the mirrors used to fabricate the hybrid can be configured as a KB telescope that when pointed refines positions to arc second precision.

  11. Cost-effective and compact wide-field fluorescent imaging on a cell-phone†

    PubMed Central

    Zhu, Hongying; Yaglidere, Oguzhan; Su, Ting-Wei; Tseng, Derek

    2011-01-01

    We demonstrate wide-field fluorescent and darkfield imaging on a cell-phone with compact, light-weight and cost-effective optical components that are mechanically attached to the existing camera unit of the cell-phone. For this purpose, we used battery powered light-emitting diodes (LEDs) to pump the sample of interest from the side using butt-coupling, where the pump light was guided within the sample cuvette to uniformly excite the specimen. The fluorescent emission from the sample was then imaged using an additional lens that was positioned right in front of the existing lens of the cell-phone camera. Because the excitation occurs through guided waves that propagate perpendicular to our detection path, an inexpensive plastic colour filter was sufficient to create the dark-field background required for fluorescent imaging, without the need for a thin-film interference filter. We validate the performance of this platform by imaging various fluorescent micro-objects in 2 colours (i.e., red and green) over a large field-of-view (FOV) of ~81 mm2 with a raw spatial resolution of ~20 μm. With additional digital processing of the captured cell-phone images, through the use of compressive sampling theory, we demonstrate ~2 fold improvement in our resolving power, achieving ~10 μm resolution without a trade-off in our FOV. Further, we also demonstrate darkfield imaging of non-fluorescent specimen using the same interface, where this time the scattered light from the objects is detected without the use of any filters. The capability of imaging a wide FOV would be exceedingly important to probe large sample volumes (e.g., >0.1 mL) of e.g., blood, urine, sputum or water, and for this end we also demonstrate fluorescent imaging of labeled white-blood cells from whole blood samples, as well as water-borne pathogenic protozoan parasites such as Giardia Lamblia cysts. Weighing only ~28 g (~1 ounce), this compact and cost-effective fluorescent imaging platform attached to a

  12. A PANCHROMATIC CATALOG OF EARLY-TYPE GALAXIES AT INTERMEDIATE REDSHIFT IN THE HUBBLE SPACE TELESCOPE WIDE FIELD CAMERA 3 EARLY RELEASE SCIENCE FIELD

    SciTech Connect

    Rutkowski, M. J.; Cohen, S. H.; Windhorst, R. A.; Kaviraj, S.; Crockett, R. M.; Silk, J.; O'Connell, R. W.; Hathi, N. P.; McCarthy, P. J.; Ryan, R. E. Jr.; Koekemoer, A.; Bond, H. E.; Yan, H.; Kimble, R. A.; Balick, B.; Calzetti, D.; Disney, M. J.; Dopita, M. A.; Frogel, J. A.; Hall, D. N. B.; and others

    2012-03-01

    In the first of a series of forthcoming publications, we present a panchromatic catalog of 102 visually selected early-type galaxies (ETGs) from observations in the Early Release Science (ERS) program with the Wide Field Camera 3 (WFC3) on the Hubble Space Telescope (HST) of the Great Observatories Origins Deep Survey-South (GOODS-S) field. Our ETGs span a large redshift range, 0.35 {approx}< z {approx}< 1.5, with each redshift spectroscopically confirmed by previous published surveys of the ERS field. We combine our measured WFC3 ERS and Advanced Camera for Surveys (ACS) GOODS-S photometry to gain continuous sensitivity from the rest-frame far-UV to near-IR emission for each ETG. The superior spatial resolution of the HST over this panchromatic baseline allows us to classify the ETGs by their small-scale internal structures, as well as their local environment. By fitting stellar population spectral templates to the broadband photometry of the ETGs, we determine that the average masses of the ETGs are comparable to the characteristic stellar mass of massive galaxies, 10{sup 11} < M{sub *}[M{sub Sun }]<10{sup 12}. By transforming the observed photometry into the Galaxy Evolution Explorer FUV and NUV, Johnson V, and Sloan Digital Sky Survey g' and r' bandpasses we identify a noteworthy diversity in the rest-frame UV-optical colors and find the mean rest-frame (FUV-V) = 3.5 and (NUV-V) = 3.3, with 1{sigma} standard deviations {approx_equal}1.0. The blue rest-frame UV-optical colors observed for most of the ETGs are evidence for star formation during the preceding gigayear, but no systems exhibit UV-optical photometry consistent with major recent ({approx}<50 Myr) starbursts. Future publications which address the diversity of stellar populations likely to be present in these ETGs, and the potential mechanisms by which recent star formation episodes are activated, are discussed.

  13. Wide-field computational imaging of pathology slides using lens-free on-chip microscopy.

    PubMed

    Greenbaum, Alon; Zhang, Yibo; Feizi, Alborz; Chung, Ping-Luen; Luo, Wei; Kandukuri, Shivani R; Ozcan, Aydogan

    2014-12-17

    Optical examination of microscale features in pathology slides is one of the gold standards to diagnose disease. However, the use of conventional light microscopes is partially limited owing to their relatively high cost, bulkiness of lens-based optics, small field of view (FOV), and requirements for lateral scanning and three-dimensional (3D) focus adjustment. We illustrate the performance of a computational lens-free, holographic on-chip microscope that uses the transport-of-intensity equation, multi-height iterative phase retrieval, and rotational field transformations to perform wide-FOV imaging of pathology samples with comparable image quality to a traditional transmission lens-based microscope. The holographically reconstructed image can be digitally focused at any depth within the object FOV (after image capture) without the need for mechanical focus adjustment and is also digitally corrected for artifacts arising from uncontrolled tilting and height variations between the sample and sensor planes. Using this lens-free on-chip microscope, we successfully imaged invasive carcinoma cells within human breast sections, Papanicolaou smears revealing a high-grade squamous intraepithelial lesion, and sickle cell anemia blood smears over a FOV of 20.5 mm(2). The resulting wide-field lens-free images had sufficient image resolution and contrast for clinical evaluation, as demonstrated by a pathologist's blinded diagnosis of breast cancer tissue samples, achieving an overall accuracy of ~99%. By providing high-resolution images of large-area pathology samples with 3D digital focus adjustment, lens-free on-chip microscopy can be useful in resource-limited and point-of-care settings. PMID:25520396

  14. Temporally focused wide-field two-photon microscopy: paraxial to vectorial.

    PubMed

    Yew, Elijah Y S; Sheppard, Colin J R; So, Peter T C

    2013-05-20

    Temporal focusing allows for optically sectioned wide-field microscopy. The optical sectioning arises because this method takes a pulsed input beam, stretches the pulses by diffracting off a grating, and focuses the stretched pulses such that only at the focal plane are the pulses re-compressed. This approach generates nonlinear optical processes at the focal plane and results in depth discrimination. Prior theoretical models of temporal focusing processes approximate the contributions of the different spectral components by their mean. This is valid for longer pulses that have narrower spectral bandwidth but results in a systematic deviation when broad spectrum, femtosecond pulses are used. Further, prior model takes the paraxial approximation but since these pulses are focused with high numerical aperture (NA) objectives, the effects of the vectorial nature of light should be considered. In this paper we present a paraxial and a vector theory of temporal focusing that takes into account the finite spread of the spectrum. Using paraxial theory we arrive at an analytical solution to the electric field at the focus for temporally focused wide-field two-photon (TF2p) microscopy as well as in the case of a spectrally chirped input beam. We find that using paraxial theory while accounting for the broad spectral spread gives results almost twice vector theory. Experiment results agree with predictions of the vector theory giving an axial full-width half maximum (FWHM) of 2.1 μmand1.8 μmrespectively as long as spectral spread is taken into account. Using our system parameters, the optical sectioning of the TF2p microscope is found to be 8 μm. The optical transfer function (OTF) of a TF2p microscope is also derived and is found to pass a significantly more limited band of axial frequencies than a point scanning two-photon (2p) microscope or a single photon (1p) confocal microscope. PMID:23736515

  15. Proto-Type Development of Optical Wide-field Patrol Network and Test Observation

    NASA Astrophysics Data System (ADS)

    Park, J.; Choi, Y.; Jo, J.; Moon, H.; Yim, H.; Park, Y.; Hae, Y.; Park, S.; Choi, J.; Son, J.

    2014-09-01

    We present a prototype system developed for optical satellite tracking and its early test observation results. The main objective of the OWL (Optical Wide-field patroL) network is to get orbital information for Korean domestic satellites using optical means only and to maintain their orbital elements. The network is composed of 5 small wide-field telescopes deployed over the world. Each observing station is operated in fully robotic manner from receiving observation schedule to reporting the result, and controlled by the headquarter located in Daejeon, Korea, where orbit calculation and observation strategy will be determined. We developed a compact telescope system for robotic observation and easy maintenance. The telescope is 0.5m of aperture diameter with Rechey-Cretian configuration and its field of view is 1.1 deg. It is equipped with 4K CCD with 9um pixel size, and its pixel scale is 1.2 arcsec/pixel. A chopper wheel with variable speed is adopted to get more points in a single shot. The CCD camera and all the rotating parts (chopper wheel, de-rotator, and filter wheel) are integrated into one compact component called a wheel station. Each observing station is equipped with a fully automatic dome and heavy duty environment monitoring system. We could get an image every 20 seconds and up to ~100 trail points in a single exposure. Each point is time-tagged by ~1/1000 second precision. For one of best cases, we could estimate satellite position with RMS ~ 0.5km accuracy in the along-track with only 4 exposures (~100 points). The first system was installed at the Mongolian site after completing verification test at the testbed site in Daejeon, Korea. The second and third system will be installed in the end of this year.

  16. Influence of Critical Current Density on Guidance Force Decay of HTS Bulk Exposed to AC Magnetic Field Perturbation in a Maglev Vehicle System

    NASA Astrophysics Data System (ADS)

    Longcai, Zhang; Jianguo, Kong

    2012-07-01

    Superconducting maglev vehicle is one of the most promising applications of HTS bulks. In such a system, the HTS bulks are always exposed to AC external magnetic field, which is generated by the inhomogeneous surface magnetic field of the NdFeB guideway. In our previous work, we studied the guidance force decay of the YBCO bulk over the NdFdB guideway used in the High-temperature superconducting maglev vehicle system with the application of the AC external magnetic field, and calculated the guidance force decay as a function of time based on an analytic model. In this paper, we investigated the influence of the critical current density on the guidance force decay of HTS bulk exposed to AC field perturbation in the maglev vehicle system and try to adopt a method to suppress the decay. From the results, it was found that the guidance force decay rate was higher for the bulk with lower critical current density. Therefore, we could suppress the guidance force decay of HTS bulk exposed to AC external magnetic field perturbation in the maglev vehicle system by improving critical current density of the bulk.

  17. Simulation of fluid flow induced by opposing ac magnetic fields in a continuous casting mold

    SciTech Connect

    Chang, F.C.; Hull, J.R.; Beitelman, L.

    1995-07-01

    A numerical simulation was performed for a novel electromagnetic stirring system employing two rotating magnetic fields. The system controls stirring flow in the meniscus region of a continuous casting mold independently from the stirring induced within the remaining volume of the mold by a main electromagnetic stirrer (M-EMS). This control is achieved by applying to the meniscus region an auxiliary electromagnetic field whose direction of rotation is opposite to that of the main magnetic field produced by the M-EMS. The model computes values and spatial distributions of electromagnetic parameters and fluid flow in the stirred pools of mercury in cylindrical and square geometries. Also predicted are the relationships between electromagnetics and fluid flows pertinent to a dynamic equilibrium of the opposing stirring swirls in the meniscus region. Results of the numerical simulation compared well with measurements obtained from experiments with mercury pools.

  18. AC field measurements of Fermilab Booster correctors using a rotating coil system

    SciTech Connect

    Velev, G.V.; DiMarco, J.; Harding, D.J.; Kashikhin, V.; Lamm, M.; Makulski, A.; Orris, D.; Schlabach, P.; Sylvester, C.; Tartaglia, M.; Tompkins, J.; /Fermilab

    2006-07-01

    The first prototype of a new corrector package for the Fermilab Booster Synchrotron is presently in production. This water-cooled package includes normal and skew dipole, quadrupole and sextupole elements to control orbit, tune and chromaticity of the beam over the full range of Booster energies (0.4-8 GeV). These correctors operate at the 15 Hz excitation cycle of the main synchrotron magnets, but must also make more rapid excursions, in some cases even switching polarity in approximately 1 ms at transition crossing. To measure the dynamic field changes during operation, a new method based on a relatively slow rotating coil system is proposed. The method pieces together the measured voltages from successive current cycles to reconstruct the field harmonics. This paper describes the method and presents initial field quality measurements from a Tevatron corrector.

  19. The DECam NEO Survey: A sensitive, wide-field search for near-Earth asteroids

    NASA Astrophysics Data System (ADS)

    Allen, Lori; Trilling, David; Valdes, Frank; Fuentes, Cesar; James, David; Herrera, David; Rajagopal, Jayadev; Burt, Brian; Axelrod, Tim

    2014-11-01

    We report preliminary results from a survey for near-Earth asteroids with the Dark Energy Camera. DECam is a facility-class 520 Megapixel wide-field imager on the 4m Blanco telescope at Cerro Tololo Inter-american Observatory. It has a 3.2 square degree field of view, and a focal plane consisting of 62 2Kx4K red-optimized CCDs. In spite of its large number of pixels, DECam reads out in less than 30 seconds, making it possible to cover a large area of sky efficiently. Compared to the largest aperture of the currently most productive NEO searches, the Blanco has an aperture that is several times larger and a comparable field of view. Our goal is to measure the size distribution of NEOs well below 140m, and we have been allocated 30 nights through the NOAO Survey program to achieve it. Here we report on results from the first 10 nights of our survey.

  20. Large-field-of-view wide-spectrum artificial reflecting superposition compound eyes

    NASA Astrophysics Data System (ADS)

    Huang, Chi-Chieh

    The study of the imaging principles of natural compound eyes has become an active area of research and has fueled the advancement of modern optics with many attractive design features beyond those available with conventional technologies. Most prominent among all compound eyes is the reflecting superposition compound eyes (RSCEs) found in some decapods. They are extraordinary imaging systems with numerous optical features such as minimum chromatic aberration, wide-angle field of view (FOV), high sensitivity to light and superb acuity to motion. Inspired by their remarkable visual system, we were able to implement the unique lens-free, reflection-based imaging mechanisms into a miniaturized, large-FOV optical imaging device operating at the wide visible spectrum to minimize chromatic aberration without any additional post-image processing. First, two micro-transfer printing methods, a multiple and a shear-assisted transfer printing technique, were studied and discussed to realize life-sized artificial RSCEs. The processes exploited the differential adhesive tendencies of the microstructures formed between a donor and a transfer substrate to accomplish an efficient release and transfer process. These techniques enabled conformal wrapping of three-dimensional (3-D) microstructures, initially fabricated in two-dimensional (2-D) layouts with standard fabrication technology onto a wide range of surfaces with complex and curvilinear shapes. Final part of this dissertation was focused on implementing the key operational features of the natural RSCEs into large-FOV, wide-spectrum artificial RSCEs as an optical imaging device suitable for the wide visible spectrum. Our devices can form real, clear images based on reflection rather than refraction, hence avoiding chromatic aberration due to dispersion by the optical materials. Compared to the performance of conventional refractive lenses of comparable size, our devices demonstrated minimum chromatic aberration, exceptional

  1. The Wide Field/Planetary Camera 2 (WFPC-2) molecular adsorber

    NASA Technical Reports Server (NTRS)

    Barengoltz, Jack; Moore, Sonya; Soules, David; Voecks, Gerald

    1995-01-01

    A device has been developed at the Jet Propulsion Laboratory, California Institute of Technology, for the adsorption of contaminants inside a space instrument during flight. The molecular adsorber was developed for use on the Wide Field Planetary Camera 2, and it has been shown to perform at its design specifications in the WFPC-2. The basic principle of the molecular adsorber is a zeolite-coated ceramic honeycomb. The arrangement is efficient for adsorption and also provides the needed rigidity to retain the special zeolite coating during the launch vibrational environment. The adsorber, on other forms, is expected to be useful for all flight instruments sensitive to internal sources of contamination. Typically, some internal contamination is unavoidable. A common design solution is to increase the venting to the exterior. However, for truly sensitive instruments, the external contamination environment is more severe. The molecular adsorber acts as a one-way vent to solve this problem. Continued development is planned for this device.

  2. FINDING PERSISTENT SOURCES WITH THE BeppoSAX/WIDE FIELD CAMERA: AN IN-DEPTH ANALYSIS

    SciTech Connect

    Capitanio, F.; Fiocchi, M.; Ubertini, P.; Bird, A. J.; Scaringi, S.

    2011-07-01

    During the operational life of the Italian/Dutch X-ray satellite (1996-2002), BeppoSAX, its two Wide Field Cameras (WFCs) performed observations that covered the full sky at different epochs. Although the majority of analysis performed on BeppoSAX WFC data concentrated on the detection of transient sources, we have now applied the same techniques developed for the INTEGRAL/IBIS survey to produce the same work with the BeppoSAX WFC data. This work represents the first unbiased source list compilation produced from the overall WFC data set optimized for faint persistent source detection. This approach recovered 182 more sources compared to the previous WFC catalog reported in Verrecchia et al. The catalog contains 404 sources detected between 3 and 17 keV, 10 of which are yet to be seen by the new generation of telescopes.

  3. Micrometeoroid Impacts on the Hubble Space Telescope Wide Field and Planetary Camera 2: Smaller Particle Impacts

    NASA Technical Reports Server (NTRS)

    Ross, D. K.; Anz-Meador, P.; Liou, J.C.; Opiela, J.; Kearsley, A. T.; Grime, G.; Webb, R.; Jeynes, C.; Palitsin, V.; Colaux, J.; Griffin, T.; Gerlach, L.; Wozniakiewicz, P. J.; Price, M. C.; Burchell, M. J.; Cole, M. J.

    2014-01-01

    The radiator shield on the Wide Field and Planetary Camera 2 (WFPC2) was subject to optical inspection following return from the Hubble Space Telescope (HST) in 2009. The survey revealed over 600 impact features of > 300 micrometers diameter, from exposure in space for 16 years. Subsequently, an international collaborative programme of analysis was organized to determine the origin of hypervelocity particles responsible for the damage. Here we describe examples of the numerous smaller micrometeoroid (MM) impact features (< 700 micrometers diameter) which excavated zinc orthotitanate (ZOT) paint from the radiator surface, but did not incorporate material from underlying Al alloy; larger impacts are described by [3]. We discuss recognition and interpretation of impactor remains, and MM compositions found on WFPC2.

  4. Morphological analysis of Bacillux polymyxa colonies: digital image analysis in wide-field microscopy

    NASA Astrophysics Data System (ADS)

    Guerrero, Lina M.; Plata G., Arturo; Rincón C., Giovanna; Gutiérrez A., Henry; Plata, Alexandra

    2013-11-01

    In the last twenty years the growth of bacterial colonies has been studied experimentally using images with different growth patterns, but the resolution of those images is in areas of tenths of microns without range information. On the other hand, theoretical studies considering the bacteria as systems with collective behavior controlled by a reduced number of parameters have been developed. The present work aims to study morphological and dynamic growth of Bacillus polymyxa colonies by the technique of digital image analysis in wide-field microscopy, which provides high resolution, both in texture and topography. Getting a three-dimensional behavior of dynamic biological systems is useful to create structures and materials with different physical and biological properties for industrial applications.

  5. Wide-field depth-sectioning fluorescence microscopy using projector-generated patterned illumination.

    PubMed

    Delica, Serafin; Blanca, Carlo Mar

    2007-10-10

    We present a simple and cost-effective wide-field, depth-sectioning, fluorescence microscope utilizing a commercial multimedia projector to generate excitation patterns on the sample. Highly resolved optical sections of fluorescent pollen grains at 1.9 microm axial resolution are constructed using the structured illumination technique. This requires grid excitation patterns to be scanned across the sample, which is straightforwardly implemented by creating slideshows of gratings at different phases, projecting them onto the sample, and synchronizing camera acquisition with slide transition. In addition to rapid dynamic pattern generation, the projector provides high illumination power and spectral excitation selectivity. We exploit these properties by imaging mouse neural cells in cultures multistained with Alexa 488 and Cy3. The spectral and structural neural information is effectively resolved in three dimensions. The flexibility and commercial availability of this light source is envisioned to open multidimensional imaging to a broader user base. PMID:17932535

  6. Wide-window angular spectrum method for optical field propagation through ABCD systems

    NASA Astrophysics Data System (ADS)

    Li, Yuanyang; Guo, Jin; Liu, Lisheng; Wang, Tingfeng; Shao, Junfeng

    2014-10-01

    The wide-window angular spectrum (WWAS) method is proposed to simulate field propagation through paraxial optical systems, mainly based on the Collins formula and the scaled Fourier transform (SFT). The application of the SFT algorithm makes the sampling processes in the input space, output space and spatial-frequency domains completely independent, and as a result, we can choose a larger calculation window size for simulating long-distance propagation without increasing the calculation burden. The sampling criteria are derived analytically and used in the numerical simulations to present the correctness and effectiveness of the WWAS algorithm. The advantages of the algorithm are shown by making a comparison with other angular spectrum methods for the free-space propagation case.

  7. Methods of Optimizing X-Ray Optical Prescriptions for Wide-Field Applications

    NASA Technical Reports Server (NTRS)

    Elsner, R. F.; O'Dell, S. L.; Ramsey, B. D.; Weisskopf, M. C.

    2010-01-01

    We are working on the development of a method for optimizing wide-field x-ray telescope mirror prescriptions, including polynomial coefficients, mirror shell relative displacements, and (assuming 4 focal plane detectors) detector placement and tilt that does not require a search through the multi-dimensional parameter space. Under the assumption that the parameters are small enough that second order expansions are valid, we show that the performance at the detector surface can be expressed as a quadratic function of the parameters with numerical coefficients derived from a ray trace through the underlying Wolter I optic. The best values for the parameters are found by solving the linear system of equations creating by setting derivatives of this function with respect to each parameter to zero. We describe the present status of this development effort.

  8. Quantitative microscopy and nanoscopy of sickle red blood cells performed by wide field digital interferometry

    NASA Astrophysics Data System (ADS)

    Shaked, Natan T.; Satterwhite, Lisa L.; Telen, Marilyn J.; Truskey, George A.; Wax, Adam

    2011-03-01

    We have applied wide-field digital interferometry (WFDI) to examine the morphology and dynamics of live red blood cells (RBCs) from individuals who suffer from sickle cell anemia (SCA), a genetic disorder that affects the structure and mechanical properties of RBCs. WFDI is a noncontact, label-free optical microscopy approach that can yield quantitative thickness profiles of RBCs and measurements of their membrane fluctuations at the nanometer scale reflecting their stiffness. We find that RBCs from individuals with SCA are significantly stiffer than those from a healthy control. Moreover, we show that the technique is sensitive enough to distinguish classes of RBCs in SCA, including sickle RBCs with apparently normal morphology, compared to the stiffer crescent-shaped sickle RBCs. We expect that this approach will be useful for diagnosis of SCA and for determining efficacy of therapeutic agents.

  9. Strategy for contamination control to improve Wide-Field/Planetary Camera far-ultraviolet performance

    NASA Technical Reports Server (NTRS)

    Leschly, Kim; Taylor, Daniel M.; Jenkins, Teresa; Barengoltz, Jack B.

    1990-01-01

    A multifaceted contamination control strategy has been developed for the second generated Wide-Field and Planetary Camera (WFPC-2) to improve the FUV stability by several orders of magnitude, compared to the first camera (WFPC-1). The strategy involves: improved on-orbit boil-off capability of the detector optics, added internal shielding and instrument venting, in-process subassembly vacuum bakeout at elevated temperatures, material substitution, sample testing in ultraclean vacuum facility, and internal instrument contamination-transport modeling. A science performance goal of 1 percent photometric accuracy at 1470 A over an extended time (of at least 30 days) has been established as a contamination control target for WFPC-2. The WFPC-2 is currently planned to be launched by the Shuttle in mid-1993 and replace the WFPC-1 which was recently launched with the HST.

  10. Sampling and Analysis of Impact Crater Residues Found on the Wide Field Planetary Camera-2 Radiator

    NASA Astrophysics Data System (ADS)

    Anz-Meador, P. D.; Liou, J.-C.; Ross, D.; Robinson, G. A.; Opiela, J. N.; Kearsley, A. T.; Grime, G. W.; Colaux, J. L.; Jeynes, C.; Palitsin, V. V.; Webb, R. P.; Griffin, T. J.; Reed, B. B.; Gerlach, L.

    2013-08-01

    After nearly 16 years in low Earth orbit (LEO), the Wide Field Planetary Camera-2 (WFPC2) was recovered from the Hubble Space Telescope (HST) in May 2009, during the 12 day shuttle mission designated STS-125. The WFPC-2 radiator had been struck by approximately 700 impactors producing crater features 300 μ m and larger in size. Following optical inspection in 2009, agreement was reached for joint NASA-ESA study of crater residues, in 2011. Over 480 impact features were extracted at NASA Johnson Space Center's (JSC) Space Exposed Hardware clean-room and curation facility during 2012, and were shared between NASA and ESA. We describe analyses conducted using scanning electron microscopy (SEM) - energy dispersive X-ray spectrometry (EDX): by NASA at JSC's Astromaterials Research and Exploration Science (ARES) Division; and for ESA at the Natural History Museum (NHM), with Ion beam analysis (IBA) using a scanned proton microbeam at the University of Surrey Ion Beam Centre (IBC).

  11. Science yield estimate with the Wide-Field Infrared Survey Telescope coronagraph

    NASA Astrophysics Data System (ADS)

    Traub, Wesley A.; Breckinridge, James; Greene, Thomas P.; Guyon, Olivier; Jeremy Kasdin, N.; Macintosh, Bruce

    2016-01-01

    The coronagraph instrument (CGI) on the Wide-Field Infrared Survey Telescope will directly image and spectrally characterize planets and circumstellar disks around nearby stars. Here we estimate the expected science yield of the CGI for known radial-velocity (RV) planets and potential circumstellar disks. The science return is estimated for three types of coronagraphs: the hybrid Lyot and shaped pupil are the currently planned designs, and the phase-induced amplitude apodizing complex mask coronagraph is the backup design. We compare the potential performance of each type for imaging as well as spectroscopy. We find that the RV targets can be imaged in sufficient numbers to produce substantial advances in the science of nearby exoplanets. To illustrate the potential for circumstellar disk detections, we estimate the brightness of zodiacal-type disks, which could be detected simultaneously during RV planet observations.

  12. Curvature wavefront sensing performance simulations for active correction of the Javalambre wide-field telescopes

    NASA Astrophysics Data System (ADS)

    Chueca, Sergio; Marín-Franch, Antonio; Cenarro, Andrés. Javier; Varela, Jesús; Ederoclite, Alessandro; Cristóbal-Hornillos, David; Hernández-Monteagudo, Carlos; Gruel, Nicolás.; Moles, Mariano; Yanes, Axel; Rueda, Fernando; Rueda, Sergio; Luis-Simoes, Roberto; Hernández-Fuertes, Javier; López-Sainz, Angel; Maícas-Sacristán, Natalio; Lamadrid, José Luis; Díaz-Martín, Miguel Chioare; Taylor, Keith

    2012-09-01

    In order to maintain image quality during Javalambre wide field telescope operations, deformations and rigid body motions must be actively controlled to minimize optical disturbances. For JST/T250 the aberrations of the telescope will be measured with four curvature sensors at the focal plane. To correct the measured distortions, the secondary mirror position (with a hexapod support) and the camera position can be modified in a control closed loop. Multiple software tools have been developed to accomplish this goal, constituting the "Observatorio Astrofísico de Javalambre" (OAJ) Active Optics Pipeline. We present a comprehensive analysis of the wave-front sensing system, including the availability of reference stars, pupil registration, wavefront estimators and the iteration matrix evaluation techniques. Some preliminary simulations have been made using a telescope model with a Optical Ray Tracing Software.

  13. Lessons Learned from the Wide Field Camera 3 TV1 Test Campaign and Correlation Effort

    NASA Technical Reports Server (NTRS)

    Peabody, Hume; Stavley, Richard; Bast, William

    2007-01-01

    In January 2004, shortly after the Columbia accident, future servicing missions to the Hubble Space Telescope (HST) were cancelled. In response to this, further work on the Wide Field Camera 3 instrument was ceased. Given the maturity level of the design, a characterization thermal test (TV1) was completed in case the mission was re-instated or an alternate mission found on which to fly the instrument. This thermal test yielded some valuable lessons learned with respect to testing configurations and modeling/correlation practices, including: 1. Ensure that the thermal design can be tested 2. Ensure that the model has sufficient detail for accurate predictions 3. Ensure that the power associated with all active control devices is predicted 4. Avoid unit changes for existing models. This paper documents the difficulties presented when these recommendations were not followed.

  14. The NOAA-9 Earth Radiation Budget Experiment Wide Field-of-View Data Set

    NASA Technical Reports Server (NTRS)

    Bush, Kathryn A.; Smith, G. Louis; Young, David F.

    1999-01-01

    The Earth Radiation Budget Experiment (ERBE) consisted of wide field-of-view (WFOV) radiometers and scanning radiometers for measuring outgoing longwave radiation and solar radiation reflected from the Earth. These instruments were carried by the dedicated Earth Radiation Budget Satellite (ERBS) and by the NOAA-9 and -10 operational spacecraft. The WFOV radiometers provided data from which instantaneous fluxes at the top of the atmosphere (TOA) are computed by use of a numerical filter algorithm. Monthly mean fluxes over a 5-degree equal angle grid are computed from the instantaneous TOA fluxes. The WFOV radiometers aboard the NOAA-9 spacecraft operated from February 1985 through December 1992, at which time a failure of the shortwave radiometer ended the usable data after nearly 8 years. This paper examines the monthly mean products from that data set.

  15. Sampling and Analysis of Impact Crater Residues Found on the Wide Field Planetary Camera-2 Radiator

    NASA Technical Reports Server (NTRS)

    Kearsley, A. T.; Grime, G. W.; Colaux, J. L.; Jeynes, C.; Palitsin, V. V.; Webb, R, P.; Griffin, T. J.; Reed, B. B.; Anz-Meador, P. D.; Kou, J.-C.; Robinson, G. A.; Opiela, J. N.; Gerlach, L.

    2013-01-01

    After nearly 16 years in low Earth orbit (LEO), the Wide Field Planetary Camera-2 (WFPC2) was recovered from the Hubble Space Telescope (HST) in May 2009, during the 12 day shuttle mission designated STS-125. The WFPC-2 radiator had been struck by approximately 700 impactors producing crater features 300 microns and larger in size. Following optical inspection in 2009, agreement was reached for joint NASA-ESA study of crater residues, in 2011. Over 480 impact features were extracted at NASA Johnson Space Center's (JSC) Space Exposed Hardware clean-room and curation facility during 2012, and were shared between NASA and ESA. We describe analyses conducted using scanning electron microscopy (SEM) - energy dispersive X-ray spectrometry (EDX): by NASA at JSC's Astromaterials Research and Exploration Science (ARES) Division; and for ESA at the Natural History Museum (NHM), with Ion beam analysis (IBA) using a scanned proton microbeam at the University of Surrey Ion Beam Centre (IBC).

  16. An optimal numerical filter for wide-field-of-view measurements of earth-emitted radiation

    NASA Technical Reports Server (NTRS)

    Smith, G. L.; House, F. B.

    1981-01-01

    A technique is described in which all data points along an arc of the orbit may be used in an optimal numerical filter for wide-field-of-view measurements of earth emitted radiation. The statistical filter design is derived whereby the filter is required to give a minimum variance estimate of the radiative exitance at discrete points along the ground track of the satellite. An equation for the optimal numerical filter is given by minimizing the estimate error variance equation with respect to the filter weights, resulting in a discrete form of the Wiener-Hopf equation. Finally, variances of the errors in the radiant exitance can be computed along the ground track and in the cross track directions.

  17. Optical Design Trade Study for the Wide Field Infrared Survey Telescope [WFIRST

    NASA Technical Reports Server (NTRS)

    Content, David A.; Goullioud, R.; Lehan, John P.; Mentzell, John E.

    2011-01-01

    The Wide Field Infrared Survey Telescope (WFIRST) mission concept was ranked first in new space astrophysics mission by the Astro2010 Decadal Survey incorporating the Joint Dark Energy Mission (JDEM)-Omega payload concept and multiple science white papers. This mission is based on a space telescope at L2 studying exoplanets [via gravitational microlensing], probing dark energy, and surveying the near infrared sky. Since the release of NWNH, the WFIRST project has been working with the WFIRST science definition team (SDT) to refine mission and payload concepts. We present the driving requirements. The current interim reference mission point design, based on the use of a 1.3m unobscured aperture three mirror anastigmat form, with focal imaging and slitless spectroscopy science channels, is consistent with the requirements, requires no technology development, and out performs the JDEM-Omega design.

  18. Tomographic reconstruction for wide-field adaptive optics systems: Fourier domain analysis and fundamental limitations.

    PubMed

    Neichel, Benoit; Fusco, Thierry; Conan, Jean-Marc

    2009-01-01

    Several wide-field-of-view adaptive optics (WFAO) concepts such as multi-conjugate AO (MCAO), multi-object AO (MOAO), and ground-layer AO (GLAO) are currently being studied for the next generation of Extremely Large Telescopes (ELTs). All these concepts will use atmospheric tomography to reconstruct the turbulent-phase volume. In this paper, we explore different reconstruction algorithms and their fundamental limitations, conducting this analysis in the Fourier domain. This approach allows us to derive simple analytical formulations for the different configurations and brings a comprehensive view of WFAO limitations. We then investigate model and statistical errors and their effect on the phase reconstruction. Finally, we show some examples of different WFAO systems and their expected performance on a 42 m telescope case. PMID:19109619

  19. Signal-to-noise ratio for the wide field-planetary camera of the Space Telescope

    NASA Technical Reports Server (NTRS)

    Zissa, D. E.

    1984-01-01

    Signal-to-noise ratios for the Wide Field Camera and Planetary Camera of the Space Telescope were calculated as a function of integration time. Models of the optical systems and CCD detector arrays were used with a 27th visual magnitude point source and a 25th visual magnitude per arc-sq. second extended source. A 23rd visual magnitude per arc-sq. second background was assumed. The models predicted signal-to-noise ratios of 10 within 4 hours for the point source centered on a signal pixel. Signal-to-noise ratios approaching 10 are estimated for approximately 0.25 x 0.25 arc-second areas within the extended source after 10 hours integration.

  20. Wide field adaptive optics laboratory demonstration with closed-loop tomographic control.

    PubMed

    Costille, Anne; Petit, Cyril; Conan, Jean-Marc; Kulcsár, Caroline; Raynaud, Henri-François; Fusco, Thierry

    2010-03-01

    HOMER, the new bench developed at ONERA devoted to wide field adaptive optics (WFAO) laboratory research, has allowed the first experimental validations of multi-conjugate adaptive optics (MCAO) and laser tomography adaptive optics (LTAO) concepts with a linear quadratic Gaussian (LQG) control approach. Results obtained in LTAO in closed loop show the significant gain in performance brought by LQG control, which allows tomographic reconstruction. We present a calibration and model identification strategy. Experimental results are shown to be consistent with end-to-end simulations. These results are very encouraging and demonstrate robustness of performance with respect to inevitable experimental uncertainties. They represent a first step for the study of very large telescope (VLT) and extremely large telescopes (ELT) instruments. PMID:20208937

  1. Wide-field FTIR microscopy using mid-IR pulse shaping.

    PubMed

    Serrano, Arnaldo L; Ghosh, Ayanjeet; Ostrander, Joshua S; Zanni, Martin T

    2015-07-13

    We have developed a new table-top technique for collecting wide-field Fourier transform infrared (FTIR) microscopic images by combining a femtosecond pulse shaper with a mid-IR focal plane array. The pulse shaper scans the delay between a pulse pair extremely rapidly for high signal-to-noise, while also enabling phase control of the individual pulses to under-sample the interferograms and subtract background. Infrared absorption images were collected for a mixture of W(CO)₆ or Mn₂(CO)₁₀ absorbed polystyrene beads, demonstrating that this technique can spatially resolve chemically distinct species. The images are sub-diffraction limited, as measured with a USAF test target patterned on CaF₂ and verified with scalar wave simulations. We also find that refractive, rather than reflective, objectives are preferable for imaging with coherent radiation. We discuss this method with respect to conventional FTIR microscopes. PMID:26191843

  2. WFC3RED: A HST Wide Field Camera 3 Image Processing Pipeline

    NASA Astrophysics Data System (ADS)

    Magee, D. K.; Bouwens, R. J.; Illingworth, G. D.

    2011-07-01

    WFC3RED is a pipeline for automatically processing imaging data taken with the Wide Field Camera 3 instrument on the Hubble Space Telescope (HST). The pipeline currently supports processing of imaging data from both the IR and UVIS channels and is written in Python and C. The automated processing steps include cosmic-ray removal (UVIS), super-sky subtraction, user defined artifact masking, robust alignment and registration for large mosaics, weight map generation, and drizzling onto a final image mosaic. WFC3RED can combined data across different HST observations, visits and proposals without the need for any pre-defined associations. WFC3RED can create imaging products with a signal-to-noise ratio that matches the most careful step-by-step manual WFC3 reductions.

  3. Wide-field FTIR microscopy using mid-IR pulse shaping

    PubMed Central

    Serrano, Arnaldo L.; Ghosh, Ayanjeet; Ostrander, Joshua S.; Zanni, Martin T.

    2015-01-01

    We have developed a new table-top technique for collecting wide-field Fourier transform infrared (FTIR) microscopic images by combining a femtosecond pulse shaper with a mid-IR focal plane array. The pulse shaper scans the delay between a pulse pair extremely rapidly for high signal-to-noise, while also enabling phase control of the individual pulses to under-sample the interferograms and subtract background. Infrared absorption images were collected for a mixture of W(CO)6 or Mn2(CO)10 absorbed polystyrene beads, demonstrating that this technique can spatially resolve chemically distinct species. The images are sub-diffraction limited, as measured with a USAF test target patterned on CaF2 and verified with scalar wave simulations. We also find that refractive, rather than reflective, objectives are preferable for imaging with coherent radiation. We discuss this method with respect to conventional FTIR microscopes. PMID:26191843

  4. A Powerful New Imager for HST: Performance and Early Science Results from Wide Field Camera 3

    NASA Technical Reports Server (NTRS)

    Kimble, Randy

    2009-01-01

    Wide Field Camera 3 (WFC3) was installed into the Hubble Space Telescope during the highly successful Servicing Mission 4 in May, 2009. WFC3 offers sensitive, high resolution imaging over a broad wavelength range from the near UV through the visible to the near IR (200nm - 1700nm). Its capabilities in the near UV and near IR ends of that range represent particularly large advances vs. those of previous HST instruments. In this talk, I will review the purpose and design of the instrument, describe its performance in flight, and highlight some of the initial scientific results from the instrument, including its use in deep infrared surveys in search of galaxies at very high redshift, in investigations of the global processes of star formation in nearby galaxies, and in the study of the recent impact on Jupiter.

  5. Progress Report on Optimizing X-ray Optical Prescriptions for Wide-Field Applications

    NASA Technical Reports Server (NTRS)

    Elsner, R. F.; O'Dell, S. L.; Ramsey, B. D.; Weisskopf, M. C.

    2011-01-01

    We report on the present status of our continuing efforts to develop a method for optimizing wide-field nested x-ray telescope mirror prescriptions. Utilizing extensive Monte-Carlo ray trace simulations, we find an analytic form for the root-mean-square dispersion of rays from a Wolter I optic on the surface of a flat focal plane detector as a function of detector tilt away from the nominal focal plane and detector displacement along the optical axis. The configuration minimizing the ray dispersion from a nested array of Wolter I telescopes is found by solving a linear system of equations for tilt and individual mirror pair displacement. Finally we outline our initial efforts at expanding this method to include higher order polynomial terms in the mirror prescriptions.

  6. Wide field of view two-photon excited fluorescence imaging, theory and applications

    NASA Astrophysics Data System (ADS)

    Stoltzfus, Caleb Ray

    Two-photon excited fluorescence (2PEF) is a unique photophysical process that has benefited many diverse areas of science. Imaging the 2PEF signal offers numerous intrinsic benefits, including low background scattering, high sample photo-stability, and high excitation selectivity. The 2PEF signal has a nonlinear dependence on excitation intensity, which has proven to be extremely useful for high resolution, three dimensional microscopy. This same nonlinear dependence, in conjunction with the typically low probability of two-photons being simultaneously absorbed, also makes 2PEF imaging difficult to scale, leaving most two-photon microscopes with a field of view (FOV) limited to less than a few mm2. This effectively limits the benefits of the unique properties of 2PEF imaging to microscopic applications. This dissertation explores the development and application of a wide FOV 2PEF imaging technique, where a FOV as large as 10 cm2 is achieved by increasing the peak photon flux of the excitation source, and expanding the illumination region. The use of this imaging technique for the in depth characterization and optimization of fluorescent proteins (FPs), as well as taking high contrast images of fingermarks is described. This new wide FOV 2PEF imaging technique greatly expands the usefulness of the unique photophysical properties of 2PEF and allows for sensitive, high contrast 2PEF imaging on a much larger scale than was previously possible.

  7. Preliminary Results from the Wide-field Infrared Survey Explorer's NEOWISE Search for Minor Planets

    NASA Astrophysics Data System (ADS)

    Mainzer, A.; Bauer, J. M.; Grav, T.; Masiero, J.; McMillan, R. S.; Walker, R.; Tholen, D. J.; Wright, E.; Eisenhardt, P.; Cutri, R.; Neowise Team

    2011-12-01

    The Wide-Field Infrared Survey Explorer (WISE) imaged the entire sky twice between January, 2010 and January, 2011 at four wavelengths spanning the near through mid-IR at sensitivities hundreds of times greater than previous surveys [1]. The WISE band-passes (3.4, 4.6, 12 and 22mm) sample the flux from most inner-solar-system bodies near the peak of their thermal emission. Overlapping sky regions were sampled repeatedly at 3 hour intervals. The same region of sky was observed a minimum of 8 times. While the primary WISE science objectives focus on ultra-luminous infrared galaxies and brown dwarfs, additions to the baseline WISE pipeline (collectively known as "NEOWISE") have enabled the detection of undiscovered moving objects, as well as previously known bodies [2]. NEOWISE has detected more than 155,000 minor planets, including more than 500 near-Earth objects (NEOs), ~2000 Jupiter Trojans, ~120 comets, and ~20 outer Solar System objects such as Centaurs. The survey has discovered ~34,000 new minor planets, including 130 new NEOs and 20 new comets. The NEOWISE data will drive a wide range of new Solar System investigations. NEOWISE allows precise determination of IR-derived diameters and albedos for minor planets throughout the Solar System [3],[4]. We will summarize the latest results from the project, including studies of the statistical properties of asteroid populations such as the NEOs, and comparisons between albedo and asteroid taxonomic classification.

  8. Wide Field CO Mapping in the Region of IRAS 19312+1950

    NASA Astrophysics Data System (ADS)

    Nakashima, Jun-ichi; Ladeyschikov, Dmitry A.; Sobolev, Andrej M.; Zhang, Yong; Hsia, Chih-Hao; Yung, Bosco H. K.

    2016-07-01

    We report the results of wide field CO mapping in the region of IRAS 19312+1950. This Infrared Astronomical Satellite (IRAS) object exhibits SiO/H2O/OH maser emission, and is embedded in a chemically rich molecular component, the origin of which is still unknown. In order to reveal the entire structure and gas mass of the surrounding molecular component for the first time, we have mapped a wide region around IRAS 19312+1950 in the 12CO J = 1–0, 13CO J = 1–0 and C18O J = 1–0 lines using the Nobeyama 45 m telescope. In conjunction with archival CO maps, we investigated a region up to 20‧ × 20‧ in size around this IRAS object. We calculated the CO gas mass assuming local thermal equilibrium, the stellar velocity through the interstellar medium assuming an analytic model of bow shock, and the absolute luminosity, using the latest archival data and trigonometric parallax distance. The derived gas mass (225 M ⊙–478 M ⊙) of the molecular component and the relatively large luminosity (2.63 × 104 L ⊙) suggest that the central SiO/H2O/OH maser source is a red supergiant rather than an asymptotic giant branch (AGB) star or post-AGB star.

  9. Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone.

    PubMed

    Zhu, Hongying; Ozcan, Aydogan

    2013-01-01

    Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. - 10 μm over a very large field-of-view of - 81 mm(2). This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water. PMID:23603893

  10. Cortical activation following chronic passive implantation of a wide-field suprachoroidal retinal prosthesis

    NASA Astrophysics Data System (ADS)

    Villalobos, Joel; Fallon, James B.; Nayagam, David A. X.; Shivdasani, Mohit N.; Luu, Chi D.; Allen, Penelope J.; Shepherd, Robert K.; Williams, Chris E.

    2014-08-01

    Objective. The research goal is to develop a wide-field retinal stimulating array for prosthetic vision. This study aimed at evaluating the efficacy of a suprachoroidal electrode array in evoking visual cortex activity after long term implantation. Approach. A planar silicone based electrode array (8 mm × 19 mm) was implanted into the suprachoroidal space in cats (ntotal = 10). It consisted of 20 platinum stimulating electrodes (600 μm diameter) and a trans-scleral cable terminated in a subcutaneous connector. Three months after implantation (nchronic = 6), or immediately after implantation (nacute = 4), an electrophysiological study was performed. Electrode total impedance was measured from voltage transients using 500 μs, 1 mA pulses. Electrically evoked potentials (EEPs) and multi-unit activity were recorded from the visual cortex in response to monopolar retinal stimulation. Dynamic range and cortical activation spread were calculated from the multi-unit recordings. Main results. The mean electrode total impedance in vivo following 3 months was 12.5 ± 0.3 kΩ. EEPs were recorded for 98% of the electrodes. The median evoked potential threshold was 150 nC (charge density 53 μC cm-2). The lowest stimulation thresholds were found proximal to the area centralis. Mean thresholds from multiunit activity were lower for chronic (181 ± 14 nC) compared to acute (322 ± 20 nC) electrodes (P < 0.001), but there was no difference in dynamic range or cortical activation spread. Significance. Suprachoroidal stimulation threshold was lower in chronic than acute implantation and was within safe charge limits for platinum. Electrode-tissue impedance following chronic implantation was higher, indicating the need for sufficient compliance voltage (e.g. 12.8 V for mean impedance, threshold and dynamic range). The wide-field suprachoroidal array reliably activated the retina after chronic implantation.

  11. Reaching the Diffraction Limit - Differential Speckle and Wide-Field Imaging for the WIYN Telescope

    NASA Technical Reports Server (NTRS)

    Scott, Nic J.; Howell, Steve; Horch, Elliott

    2016-01-01

    Speckle imaging allows telescopes to achieve diffraction limited imaging performance. The technique requires cameras capable of reading out frames at a very fast rate, effectively 'freezing out' atmospheric seeing. The resulting speckles can be correlated and images reconstructed that are at the diffraction limit of the telescope. These new instruments are based on the successful performance and design of the Differential Speckle Survey Instrument (DSSI).The instruments are being built for the Gemini-N and WIYN telescopes and will be made available to the community via the peer review proposal process. We envision their primary use to be validation and characterization of exoplanet targets from the NASA, K2 and TESS missions and RV discovered exoplanets. Such targets will provide excellent follow-up candidates for both the WIYN and Gemini telescopes. We expect similar data quality in speckle imaging mode with the new instruments. Additionally, both cameras will have a wide-field mode and standard SDSS filters. They will be highly versatile instruments and it is that likely many other science programs will request time on the cameras. The limiting magnitude for speckle observations will remain around 13-14th at WIYN and 16-17th at Gemini, while wide-field, normal CCD imaging operation should be able to go to much fainter, providing usual CCD imaging and photometric capabilities. The instruments will also have high utility as scoring cameras for telescope engineering purposes, or other applications where high time resolution is needed. Instrument support will be provided, including a software pipeline that takes raw speckle data to fully reconstructed images.

  12. Wide-field Fluorescent Microscopy and Fluorescent Imaging Flow Cytometry on a Cell-phone

    PubMed Central

    Zhu, Hongying; Ozcan, Aydogan

    2013-01-01

    Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. ~ 10 μm over a very large field-of-view of ~ 81 mm2. This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water. PMID:23603893

  13. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    NASA Astrophysics Data System (ADS)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  14. Automatic Processing of Chinese GF-1 Wide Field of View Images

    NASA Astrophysics Data System (ADS)

    Zhang, Y.; Wan, Y.; Wang, B.; Kang, Y.; Xiong, J.

    2015-04-01

    The wide field of view (WFV) imaging instrument carried on the Chinese GF-1 satellite includes four cameras. Each camera has 200km swath-width that can acquire earth image at the same time and the observation can be repeated within only 4 days. This enables the applications of remote sensing imagery to advance from non-scheduled land-observation to periodically land-monitoring in the areas that use the images in such resolutions. This paper introduces an automatic data analysing and processing technique for the wide-swath images acquired by GF-1 satellite. Firstly, the images are validated by a self-adaptive Gaussian mixture model based cloud detection method to confirm whether they are qualified and suitable to be involved into the automatic processing workflow. Then the ground control points (GCPs) are quickly and automatically matched from the public geo-information products such as the rectified panchromatic images of Landsat-8. Before the geometric correction, the cloud detection results are also used to eliminate the invalid GCPs distributed in the cloud covered areas, which obviously reduces the ratio of blunders of GCPs. The geometric correction module not only rectifies the rational function models (RFMs), but also provides the self-calibration model and parameters for the non-linear distortion, and it is iteratively processed to detect blunders. The maximum geometric distortion in WFV image decreases from about 10-15 pixels to 1-2 pixels when compensated by self-calibration model. The processing experiments involve hundreds of WFV images of GF-1 satellite acquired from June to September 2013, which covers the whole mainland of China. All the processing work can be finished by one operator within 2 days on a desktop computer made up by a second-generation Intel Core-i7 CPU and a 4-solid-State-Disk array. The digital ortho maps (DOM) are automatically generated with 3 arc second Shuttle Radar Topography Mission (SRTM). The geometric accuracies of the

  15. Low ac loss geometries in YBCO coated conductors and impact on conductor stability

    SciTech Connect

    Duckworth, Robert C; List III, Frederick Alyious; Paranthaman, Mariappan Parans; Rupich, M. W.; Zhang, W.; Xie, Y. Y.; Selvamanickam, V.

    2007-01-01

    Reduction of ac losses in applied ac fields can be accomplished through either the creation of filaments and bridging in YBCO coated conductors or an assembly of narrow width YBCO tapes. The ac losses for each of these geometries were measured at 77 K in perpendicular ac fields up to 100 mT. While ac loss reduction was achieved with YBCO filaments created through laser scribing and inkjet deposition, the assembly of stacked YBCO conductor provides an alternative method of ac loss reduction. When compared to a 4-mm wide YBCO coated conductor with a critical current of 60 A, the ac loss in a stack of 2-mm wide YBCO coated conductors with a similar total critical current was reduced. While the reduction in ac loss in a 2-mm wide stack coincided with the reduction in the engineering current density of the conductor, further reduction of ac loss was obtained through the splicing of the 2-mm wide tapes with low resistance solders. To better determine the practicality of these methods from a stability point of view, a numerical analysis was carried out to determine the influence of bridging and splicing on stability of a YBCO coated conductor for both liquid nitrogen-cooled and conduction cooled geometries.

  16. High-resolution LCD projector for extra-wide-field-of-view head-up display

    NASA Astrophysics Data System (ADS)

    Brown, Robert D.; Modro, David H.; Quast, Gerhardt A.; Wood, Robert B.

    2003-09-01

    LCD projection-based cockpit displays are beginning to make entry into military and commercial aircraft. Customers for commercial Head-Up Displays (HUDs)(including airframe manufacturers) are now interested in the adaptation of the technology into existing and future HUD optical systems. LCD projection can improve mean-time-between-failure rates because the LCDs are very robust and the light sources can be replaced with scheduled maintenance by the customer without the need for re-calibration. LCD projectors promise to lower the cost of the HUD because the cost of these displays continues to drop while the cost of CRTs remain stable. LCD projectors provide the potential for multi-colors, higher brightness raster, and all-digital communication between the flight computer and display unit. Another potential benefit of LCD projection is the ability to increase field of view and viewing eyebox without exceeding existing power budgets or reducing display lifetime and reliability compared to the capabilities provided by CRTs today. This paper describes the performance requirements and improved performance of a third-generation LCD projection image source for use in a wide field of view head-up display (HUD) optical system. This paper will focus on new HUD requirements and the application of various technologies such as LCOS microdisplays, arc lamps, and rear-projection screens. Measured performance results are compared to the design requirements.

  17. Characterization of flight detector arrays for the wide-field infrared survey explorer

    NASA Astrophysics Data System (ADS)

    Mainzer, Amy; Larsen, Mark; Stapelbroek, Maryn G.; Hogue, Henry; Garnett, James; Zandian, Majid; Mattson, Reed; Masterjohn, Stacy; Livingston, John; Lingner, Nicole; Alster, Natali; Ressler, Michael; Masci, Frank

    2008-07-01

    The Wide-field Infrared Survey Explorer is a NASA Midex mission launching in late 2009 that will survey the entire sky at 3.3, 4.7, 12, and 23 microns (PI: Ned Wright, UCLA). Its primary scientific goals are to find the nearest stars (actually most likely to be brown dwarfs) and the most luminous galaxies in the universe. WISE uses three dichroic beamsplitters to take simultaneous images in all four bands using four 1024×1024 detector arrays. The 3.3 and 4.7 micron channels use HgCdTe arrays, and the 12 and 23 micron bands employ Si:As arrays. In order to make a 1024×1024 Si:As array, a new multiplexer had to be designed and produced. The HgCdTe arrays were developed by Teledyne Imaging Systems, and the Si:As array were made by DRS. All four flight arrays have been delivered to the WISE payload contractor, Space Dynamics Laboratory. We present initial ground-based characterization results for the WISE arrays, including measurements of read noise, dark current, flat field and latent image performance, etc. These characterization data will be useful in producing the final WISE data product, an all-sky image atlas and source catalog.

  18. Static and predictive tomographic reconstruction for wide-field multi-object adaptive optics systems.

    PubMed

    Correia, C; Jackson, K; Véran, J-P; Andersen, D; Lardière, O; Bradley, C

    2014-01-01

    Multi-object adaptive optics (MOAO) systems are still in their infancy: their complex optical designs for tomographic, wide-field wavefront sensing, coupled with open-loop (OL) correction, make their calibration a challenge. The correction of a discrete number of specific directions in the field allows for streamlined application of a general class of spatio-angular algorithms, initially proposed in Whiteley et al. [J. Opt. Soc. Am. A15, 2097 (1998)], which is compatible with partial on-line calibration. The recent Learn & Apply algorithm from Vidal et al. [J. Opt. Soc. Am. A27, A253 (2010)] can then be reinterpreted in a broader framework of tomographic algorithms and is shown to be a special case that exploits the particulars of OL and aperture-plane phase conjugation. An extension to embed a temporal prediction step to tackle sky-coverage limitations is discussed. The trade-off between lengthening the camera integration period, therefore increasing system lag error, and the resulting improvement in SNR can be shifted to higher guide-star magnitudes by introducing temporal prediction. The derivation of the optimal predictor and a comparison to suboptimal autoregressive models is provided using temporal structure functions. It is shown using end-to-end simulations of Raven, the MOAO science, and technology demonstrator for the 8 m Subaru telescope that prediction allows by itself the use of 1-magnitude-fainter guide stars. PMID:24561945

  19. Demonstration of the Wide-Field Imaging Interferometer Testbed Using a Calibrated Hyperspectral Image Projector

    NASA Technical Reports Server (NTRS)

    Bolcar, Matthew R.; Leisawitz, David; Maher, Steve; Rinehart, Stephen

    2012-01-01

    The Wide-field Imaging Interferometer testbed (WIIT) at NASA's Goddard Space Flight Center uses a dual-Michelson interferometric technique. The WIIT combines stellar interferometry with Fourier-transform interferometry to produce high-resolution spatial-spectral data over a large field-of-view. This combined technique could be employed on future NASA missions such as the Space Infrared Interferometric Telescope (SPIRIT) and the Sub-millimeter Probe of the Evolution of Cosmic Structure (SPECS). While both SPIRIT and SPECS would operate at far-infrared wavelengths, the WIIT demonstrates the dual-interferometry technique at visible wavelengths. The WIIT will produce hyperspectral image data, so a true hyperspectral object is necessary. A calibrated hyperspectral image projector (CHIP) has been constructed to provide such an object. The CHIP uses Digital Light Processing (DLP) technology to produce customized, spectrally-diverse scenes. CHIP scenes will have approximately 1.6-micron spatial resolution and the capability of . producing arbitrary spectra in the band between 380 nm and 1.6 microns, with approximately 5-nm spectral resolution. Each pixel in the scene can take on a unique spectrum. Spectral calibration is achieved with an onboard fiber-coupled spectrometer. In this paper we describe the operation of the CHIP. Results from the WIIT observations of CHIP scenes will also be presented.

  20. Water-Immersible MEMS scanning mirror designed for wide-field fast-scanning photoacoustic microscopy

    NASA Astrophysics Data System (ADS)

    Yao, Junjie; Huang, Chih-Hsien; Martel, Catherine; Maslov, Konstantin I.; Wang, Lidai; Yang, Joon-Mo; Gao, Liang; Randolph, Gwendalyn; Zou, Jun; Wang, Lihong V.

    2013-03-01

    By offering images with high spatial resolution and unique optical absorption contrast, optical-resolution photoacoustic microscopy (OR-PAM) has gained increasing attention in biomedical research. Recent developments in OR-PAM have improved its imaging speed, but have sacrificed either the detection sensitivity or field of view or both. We have developed a wide-field fast-scanning OR-PAM by using a water-immersible MEMS scanning mirror (MEMS-ORPAM). Made of silicon with a gold coating, the MEMS mirror plate can reflect both optical and acoustic beams. Because it uses an electromagnetic driving force, the whole MEMS scanning system can be submerged in water. In MEMS-ORPAM, the optical and acoustic beams are confocally configured and simultaneously steered, which ensures uniform detection sensitivity. A B-scan imaging speed as high as 400 Hz can be achieved over a 3 mm scanning range. A diffraction-limited lateral resolution of 2.4 μm in water and a maximum imaging depth of 1.1 mm in soft tissue have been experimentally determined. Using the system, we imaged the flow dynamics of both red blood cells and carbon particles in a mouse ear in vivo. By using Evans blue dye as the contrast agent, we also imaged the flow dynamics of lymphatic vessels in a mouse tail in vivo. The results show that MEMS-OR-PAM could be a powerful tool for studying highly dynamic and time-sensitive biological phenomena.

  1. Revisiting Earth Radiation Budget from ERBE Wide-Field-of-View Nonscanner

    NASA Astrophysics Data System (ADS)

    Shrestha, A. K.; Kato, S.; Wong, T.; Stackhouse, P. W.; Smith, G. L.; Rose, F. G.; Miller, W. F.; Bush, K.; Rutan, D. A.; Minnis, P.; Doelling, D.

    2014-12-01

    Earth Radiation Budget Experiment (ERBE) wide-field-of-view (WFOV) nonscanner on Earth Radiation Budget Satellite (ERBS) and NOAA-9/NOAA-10 provided broadband shortwave and longwave irradiances from 1985 to 1998. The observations from nonscanner at satellite altitude are converted to TOA flux by inversion processes, which involve applying so-called shape factors. However, the nonscanner processing used only one partly cloudy scene type to determine the shape factor. In addition, it does not consider spectral dependent shortwave filter degradation. Based on knowledge from recent developments in the CERES process, we propose to revise inversion processes for ERBS, NOAA9, and NoAA10 WFOV nonscanners. We will consider spectral dependent degradation of the shortwave filter transmissivity and apply scene type dependent shape factors. In the proposed inversion process, we will use imager derived cloud fraction to identify the scene type over the field of view of nonscanner instruments. In this presentation, we will present proposed inversion processes and some preliminary results.

  2. LAIWO: a new wide-field CCD camera for Wise Observatory

    NASA Astrophysics Data System (ADS)

    Baumeister, Harald; Afonso, Cristina; Marien, Karl-Heinz; Klein, Ralf

    2006-06-01

    LAIWO is a new CCD wide-field camera for the 40-inch Ritchey-Chretien telescope at Wise Observatory in Mitzpe Ramon/Israel. The telescope is identical to the 40-in. telescope at Las Campanas Observatory, Chile, which is described in [2]. LAIWO was designed and built at Max-Planck-Institute for Astronomy in Heidelberg, Germany. The scientific aim of the instrument is to detect Jupiter-sized extra-solar planets around I=14-15 magnitude stars with the transit method, which relies on the temporary drop in brightness of the parent star harboring the planet. LAIWO can observe a 1.4 x 1.4 degree field-of-view and has four CCDs with 4096*4096 pixels each The Fairchild Imaging CCDs have a pixel size of 15 microns. Since they are not 2-side buttable, they are arranged with spacings between the chips that is equal to the size of a single CCD minus a small overlap. The CCDs are cooled by liquid nitrogen to a temperature of about -100 °C. The four science CCDs and the guider CCD are mounted on a common cryogenic plate which can be adjusted in three degrees of freedom. Each of these detectors can also be adjusted independently by a similar mechanism. The instrument contains large shutter and filter mechanisms, both designed in a modular way for fast exchange and easy maintenance.

  3. The silicon micro-strip detector plane for the LOFT/wide-field monitor

    NASA Astrophysics Data System (ADS)

    Goldwurm, A.; Ferrando, P.; Götz, D.; Laurent, P.; Lebrun, F.; Limousin, O.; Basa, S.; Bertoli, W.; Delagnes, Eric; Dolgorouky, Y.; Gevin, O.; Gros, A.; Gouiffes, C.; Jeanneau, F.; Lachaud, C.; Llored, M.; Olivetto, C.; Prevot, G.; Renaud, D.; Rodriguez, J.; Rossin, C.; Schanne, S.; Soldi, S.; Varniere, P.

    2012-09-01

    The main objective of the Wide Field Monitor (WFM) on the LOFT mission is to provide unambiguous detection of the high-energy sources in a large field of view, in order to support science operations of the LOFT primary instrument, the LAD. The monitor will also provide by itself a large number of results on the timing and spectral behavior of hundreds of galactic compact objects, Active Galactic Nuclei and Gamma-Ray Bursts. The WFM is based on the coded aperture concept where a position sensitive detector records the shadow of a mask projected by the celestial sources. The proposed WFM detector plane, based on Double Sided micro-Strip Silicon Detectors (DSSD), will allow proper 2-dimensional recording of the projected shadows. Indeed the positioning of the photon interaction in the detector with equivalent fine resolution in both directions insures the best imaging capability compatible with the allocated budgets for this telescope on LOFT. We will describe here the overall configuration of this 2D-WFM and the design and characteristics of the DSSD detector plane including its imaging and spectral performances. We will also present a number of simulated results discussing the advantages that this configuration offers to LOFT. A DSSD-based WFM will in particular reduce significantly the source confusion experienced by the WFM in crowded regions of the sky like the Galactic Center and will in general increase the observatory science capability of the mission.

  4. Performance verification testing for HET wide-field upgrade tracker in the laboratory

    NASA Astrophysics Data System (ADS)

    Good, John; Hayes, Richard; Beno, Joseph; Booth, John; Cornell, Mark E.; Hill, Gary J.; Lee, Hanshin; Mock, Jason; Rafal, Marc; Savage, Richard; Soukup, Ian

    2010-07-01

    To enable the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX), the McDonald Observatory (MDO) and the Center for Electro-mechanics (CEM) at the University of Texas at Austin are developing a new HET tracker in support of the Wide-Field Upgrade (WFU) and the Visible Integral-Field Replicable Unit Spectrograph (VIRUS). The precision tracker is required to maintain the position of a 3,100 kg payload within ten microns of its desired position relative to the telescope's primary mirror. The hardware system to accomplish this has ten precision controlled actuators. Prior to installation on the telescope, full performance verification is required of the completed tracker in CEM's lab, without a primary mirror or the telescope's final instrument package. This requires the development of a laboratory test stand capable of supporting the completed tracker over its full range of motion, as well as means of measurement and methodology that can verify the accuracy of the tracker motion over full travel (4m diameter circle, 400 mm deep, with 9 degrees of tip and tilt) at a cost and schedule in keeping with the HET WFU requirements. Several techniques have been evaluated to complete this series of tests including: photogrammetry, laser tracker, autocollimator, and a distance measuring interferometer, with the laser tracker ultimately being identified as the most viable method. The design of the proposed system and its implementation in the lab is presented along with the test processes, predicted accuracy, and the basis for using the chosen method*.

  5. Broadband and Wide Field-of-view Plasmonic Metasurface-enabled Waveplates

    NASA Astrophysics Data System (ADS)

    Jiang, Zhi Hao; Lin, Lan; Ma, Ding; Yun, Seokho; Werner, Douglas H.; Liu, Zhiwen; Mayer, Theresa S.

    2014-12-01

    Quasi two-dimensional metasurfaces composed of subwavelength nanoresonator arrays can dramatically alter the properties of light in an ultra-thin planar geometry, enabling new optical functions such as anomalous reflection and refraction, polarization filtering, and wavefront modulation. However, previous metasurface-based nanostructures suffer from low efficiency, narrow bandwidth and/or limited field-of-view due to their operation near the plasmonic resonance. Here we demonstrate plasmonic metasurface-based nanostructures for high-efficiency, angle-insensitive polarization transformation over a broad octave-spanning bandwidth. The structures are realized by optimizing the anisotropic response of an array of strongly coupled nanorod resonators to tailor the interference of light at the subwavelength scale. Nanofabricated reflective half-wave and quarter-wave plates designed using this approach have measured polarization conversion ratios and reflection magnitudes greater than 92% over a broad wavelength range from 640 to 1290 nm and a wide field-of-view up to +/-40°. This work outlines a versatile strategy to create metasurface-based photonics with diverse optical functionalities.

  6. Wide-field observations in the SDSS Stripe 82 with the European VLBI Network

    NASA Astrophysics Data System (ADS)

    Cao, H.-M.; Gurvits, L. I.; Yang, J.; Hong, X.-Y.; Frey, S.; Paragi, Z.; Deller, A. T.; Ivezić, Ž.

    2014-07-01

    We observed an area of sky located within the SDSS Stripe 82 field at 1.6 GHz with the European VLBI Network (EVN). There are fifteen mJy/sub-mJy radio sources within the primary beam of a typical 30-m class EVN radio telescope. Our aim was to obtain information on compact radio structures of all VLBI-detectable sources within this primary beam area. The source of particular interest is the recently identified radio quasar J222843.54+011032.2 (J2228+0110) at z = 5.95. The data correlation was performed at the EVN software correlator at JIVE (SFXC). Three targets (J2228+0110, J222851.45+011203.4, J222941.76+011428.5) were detected, all three with position offsets not exceeding the 3σ accuracy of the original low-resolution radio surveys. The detection rate of 20% is consistent with other wide-field VLBI experiments carried out recently (e.g. Middelberg et al. 2013). The project presented here demonstrates the ability of EVN in multiple-phase-centre experiments and paves the way for future large-scale EVN surveys of compact structures in extragalactic radio sources using the multiple-phase-centre VLBI technique.

  7. Broadband and Wide Field-of-view Plasmonic Metasurface-enabled Waveplates

    PubMed Central

    Jiang, Zhi Hao; Lin, Lan; Ma, Ding; Yun, Seokho; Werner, Douglas H.; Liu, Zhiwen; Mayer, Theresa S.

    2014-01-01

    Quasi two-dimensional metasurfaces composed of subwavelength nanoresonator arrays can dramatically alter the properties of light in an ultra-thin planar geometry, enabling new optical functions such as anomalous reflection and refraction, polarization filtering, and wavefront modulation. However, previous metasurface-based nanostructures suffer from low efficiency, narrow bandwidth and/or limited field-of-view due to their operation near the plasmonic resonance. Here we demonstrate plasmonic metasurface-based nanostructures for high-efficiency, angle-insensitive polarization transformation over a broad octave-spanning bandwidth. The structures are realized by optimizing the anisotropic response of an array of strongly coupled nanorod resonators to tailor the interference of light at the subwavelength scale. Nanofabricated reflective half-wave and quarter-wave plates designed using this approach have measured polarization conversion ratios and reflection magnitudes greater than 92% over a broad wavelength range from 640 to 1290 nm and a wide field-of-view up to ±40°. This work outlines a versatile strategy to create metasurface-based photonics with diverse optical functionalities. PMID:25524830

  8. Broadband and wide field-of-view plasmonic metasurface-enabled waveplates.

    PubMed

    Jiang, Zhi Hao; Lin, Lan; Ma, Ding; Yun, Seokho; Werner, Douglas H; Liu, Zhiwen; Mayer, Theresa S

    2014-01-01

    Quasi two-dimensional metasurfaces composed of subwavelength nanoresonator arrays can dramatically alter the properties of light in an ultra-thin planar geometry, enabling new optical functions such as anomalous reflection and refraction, polarization filtering, and wavefront modulation. However, previous metasurface-based nanostructures suffer from low efficiency, narrow bandwidth and/or limited field-of-view due to their operation near the plasmonic resonance. Here we demonstrate plasmonic metasurface-based nanostructures for high-efficiency, angle-insensitive polarization transformation over a broad octave-spanning bandwidth. The structures are realized by optimizing the anisotropic response of an array of strongly coupled nanorod resonators to tailor the interference of light at the subwavelength scale. Nanofabricated reflective half-wave and quarter-wave plates designed using this approach have measured polarization conversion ratios and reflection magnitudes greater than 92% over a broad wavelength range from 640 to 1290 nm and a wide field-of-view up to ± 40°. This work outlines a versatile strategy to create metasurface-based photonics with diverse optical functionalities. PMID:25524830

  9. An Automatic Technique for Finding Faint Moving Objects in Wide Field CCD Images

    NASA Astrophysics Data System (ADS)

    Hainaut, O. R.; Meech, K. J.

    1996-09-01

    The traditional method used to find moving objects in astronomical images is to blink pairs or series of frames after registering them to align the background objects. While this technique is extremely efficient in terms of the low signal-to-noise ratio that the human sight can detect, it proved to be extremely time-, brain- and eyesight-consuming. The wide-field images provided by the large CCD mosaic recently built at IfA cover a field of view of 20 to 30' over 8192(2) pixels. Blinking such images is an enormous task, comparable to that of blinking large photographic plates. However, as the data are available digitally (each image occupying 260Mb of disk space), we are developing a set of computer codes to perform the moving object identification in sets of frames. This poster will describe the techniques we use in order to reach a detection efficiency as good as that of a human blinker; the main steps are to find all the objects in each frame (for which we rely on ``S-Extractor'' (Bertin & Arnouts (1996), A&ASS 117, 393), then identify all the background objects, and finally to search the non-background objects for sources moving in a coherent fashion. We will also describe the results of this method applied to actual data from the 8k CCD mosaic. {This work is being supported, in part, by NSF grant AST 92-21318.}

  10. Recent progress in the simulation and synthesis of Wide Field Imaging Interferometry Testbed (WIIT) data

    NASA Astrophysics Data System (ADS)

    Juanola-Parramon, Roser; Leisawitz, David; Bolcar, Matthew R.; Iacchetta, Alexander; Maher, Stephen F.; Rinehart, Stephen

    2016-06-01

    The Wide-field Imaging Interferometry Testbed (WIIT) is a double Fourier interferometer (DF) operating at optical wavelengths, and provides data that are highly representative of those from a space-based far-infrared interferometer like the Space Infrared Interferometric Telescope (SPIRIT). Developed at NASA’s Goddard Space Flight Center, this testbed produces high-quality interferometric data and is capable of observing spatially and spectrally complex hyperspectral test scenes, from geometrically simple to astronomically representative test scenes.Here we present the simulation of recent WIIT measurements using the Far-infrared Interferometer Instrument Simulator (FIInS). This simulation enables us to compare a synthesized spatial-spectral data cube based on FIInS-generated DF data with the input hyperspectral test scene. FIInS has been modified to perform the calculations at optical wavelengths and to include an extended field of view due to the presence of a detector array. The results from FIInS are compared with the results obtained from recent measurements with WIIT. For this current study, the test scene under consideration spatially consists of four reference point sources intended for spectral and spatial calibration, and six science sources, comprised of binary systems. Each binary pair member has a unique spectrum. Our results demonstrate that FIInS accurately describes the performance of a real double Fourier interferometer, and that the expected hyperspectral data cube can be reconstructed from synthetic or real interferometric data.

  11. The Wide-Area X-ray Survey in the Legacy Stripe 82 Field

    NASA Astrophysics Data System (ADS)

    LaMassa, S.; Urry, M.; Cappelluti, N.; Comastri, A.; Glikman, E.; Richards, G.; B"ohringer, H.

    2016-06-01

    We are carrying out a wide-area X-ray survey in the Sloan Digital Sky Survey Stripe 82 field to uncover how luminous, obscured AGN evolve over cosmic time and the role they play in galaxy evolution. Stripe 82 is a legacy field with a high level of spectroscopic completeness and rich multi-wavelength coverage from the ultraviolet to far-infrared, including Spitzer and Herschel imaging. Our Stripe 82X survey currently reaches 31 deg^{2}, with ˜6200 X-ray point sources detected at ≥5σ level. I will review the characteristics of this survey, on-going programs to target obscured AGN candidates, and how we can use the lessons learned from the synergistic multi-wavelength coverage to develop strategic plans for future surveys and missions. Finally, I will comment on how extending the Stripe 82X survey area to 100 deg^{2} will provide unprecedented insight into the high-L (Lx > 10^{45} erg/s), high-z (z > 2) AGN population.

  12. THE WIDE-AREA ENERGY STORAGE AND MANAGEMENT SYSTEM PHASE II Final Report - Flywheel Field Tests

    SciTech Connect

    Lu, Ning; Makarov, Yuri V.; Weimar, Mark R.; Rudolph, Frank; Murthy, Shashikala; Arseneaux, Jim; Loutan, Clyde; Chowdhury, S.

    2010-08-31

    This research was conducted by Pacific Northwest National Laboratory (PNNL) operated for the U.S. department of Energy (DOE) by Battelle Memorial Institute for Bonneville Power Administration (BPA), California Institute for Energy and Environment (CIEE) and California Energy Commission (CEC). A wide-area energy management system (WAEMS) is a centralized control system that operates energy storage devices (ESDs) located in different places to provide energy and ancillary services that can be shared among balancing authorities (BAs). The goal of this research is to conduct flywheel field tests, investigate the technical characteristics and economics of combined hydro-flywheel regulation services that can be shared between Bonneville Power Administration (BPA) and California Independent System Operator (CAISO) controlled areas. This report is the second interim technical report for Phase II of the WAEMS project. This report presents: 1) the methodology of sharing regulation service between balancing authorities, 2) the algorithm to allocate the regulation signal between the flywheel and hydro power plant to minimize the wear-and-tear of the hydro power plants, 3) field results of the hydro-flywheel regulation service (conducted by the Beacon Power), and 4) the performance metrics and economic analysis of the combined hydro-flywheel regulation service.

  13. Wide-field lensless fluorescent microscopy using a tapered fiber-optic faceplate on a chip†

    PubMed Central

    Coskun, Ahmet F.; Sencan, Ikbal; Su, Ting-Wei; Ozcan, Aydogan

    2011-01-01

    We demonstrate lensless fluorescent microscopy over a large field-of-view of ~60 mm2 with a spatial resolution of <4 μm. In this on-chip fluorescent imaging modality, the samples are placed on a fiber-optic faceplate that is tapered such that the density of the fiber-optic waveguides on the top facet is >5 fold larger than the bottom one. Placed on this tapered faceplate, the fluorescent samples are pumped from the side through a glass hemisphere interface. After excitation of the samples, the pump light is rejected through total internal reflection that occurs at the bottom facet of the sample substrate. The fluorescent emission from the sample is then collected by the smaller end of the tapered faceplate and is delivered to an opto-electronic sensor-array to be digitally sampled. Using a compressive sampling algorithm, we decode these raw lensfree images to validate the resolution (<4 μm) of this on-chip fluorescent imaging platform using microparticles as well as labeled Giardia muris cysts. This wide-field lensfree fluorescent microscopy platform, being compact and high-throughput, might provide a valuable tool especially for cytometry, rare cell analysis (involving large area microfluidic systems) as well as for microarray imaging applications. PMID:21283900

  14. Electro-phoretic rotation and orientation of polarizable spheroidal particles in AC fields

    NASA Astrophysics Data System (ADS)

    Miloh, Touvia; Goldstein, Ben Weis

    2015-02-01

    A theoretical study is provided for determining the angular rotation rate of an ideally polarized (metallic) spheroidal particle freely suspended in a symmetric electrolyte under general alternating current ambient electric excitations. In particular, we discuss cases of electro-rotation (ROT) and electro-orientation (EOR) of such nano/micro particles incited by two orthogonal electric field components which may be out of phase. The analysis is carried under the Poisson-Nernst-Planck approximation and the "weak" field model. The analytic expressions thus obtained are valid for a conducting prolate spheroid with arbitrary eccentricity including the limiting cases of isotropic spheres and infinitely long cylindrical rods. The total dipolophoretic (DIP) angular velocity is decomposed from contributions due to dielectrophoresis (DEP) induced by the dipole-moment within the particle and by the induced-charge electrophoresis (ICEP) mechanism near the conducting surface. It is demonstrated that the explicit expressions for the DIP angular velocities reduce to the well-known ROT solution for the sphere as well as to the recently found expressions (based on slender-body approximation) for both ROT and EOR of metal nanowires [Arcenegui et al., "Electro-orientation and electrorotation of metal nanowires," Phys. Rev. E 88(6), 063018 (2013)]. Some comparisons with available experimental data are also provided for slender spheroidal geometries including a detailed discussion of DEP and ICEP effects and their relative contributions to the overall DIP rotational velocity.

  15. AC electric field for rapid assembly of nanostructured polyaniline onto microsized gap for sensor devices.

    PubMed

    La Ferrara, Vera; Rametta, Gabriella; De Maria, Antonella

    2015-07-01

    Interconnected network of nanostructured polyaniline (PANI) is giving strong potential for enhancing device performances than bulk PANI counterparts. For nanostructured device processing, the main challenge is to get prototypes on large area by requiring precision, low cost and high rate assembly. Among processes meeting these requests, the alternate current electric fields are often used for nanostructure assembling. For the first time, we show the assembly of nanostructured PANI onto large electrode gaps (30-60 μm width) by applying alternate current electric fields, at low frequencies, to PANI particles dispersed in acetonitrile (ACN). An important advantage is the short assembly time, limited to 5-10 s, although electrode gaps are microsized. That encouraging result is due to a combination of forces, such as dielectrophoresis (DEP), induced-charge electrokinetic (ICEK) flow and alternate current electroosmotic (ACEO) flow, which speed up the assembly process when low frequencies and large electrode gaps are used. The main achievement of the present study is the development of ammonia sensors created by direct assembling of nanostructured PANI onto electrodes. Sensors exhibit high sensitivity to low gas concentrations as well as excellent reversibility at room temperature, even after storage in air. PMID:26009866

  16. Frequency-dependent electrodeformation of giant phospholipid vesicles in AC electric field

    PubMed Central

    2010-01-01

    A model of vesicle electrodeformation is described which obtains a parametrized vesicle shape by minimizing the sum of the membrane bending energy and the energy due to the electric field. Both the vesicle membrane and the aqueous media inside and outside the vesicle are treated as leaky dielectrics, and the vesicle itself is modeled as a nearly spherical shape enclosed within a thin membrane. It is demonstrated (a) that the model achieves a good quantitative agreement with the experimentally determined prolate-to-oblate transition frequencies in the kilohertz range and (b) that the model can explain a phase diagram of shapes of giant phospholipid vesicles with respect to two parameters: the frequency of the applied alternating current electric field and the ratio of the electrical conductivities of the aqueous media inside and outside the vesicle, explored in a recent paper (S. Aranda et al., Biophys J 95:L19–L21, 2008). A possible use of the frequency-dependent shape transitions of phospholipid vesicles in conductometry of microliter samples is discussed. PMID:21886342

  17. Refined Adaptive Optics simulation with wide field of view for the ELT.

    NASA Astrophysics Data System (ADS)

    Chebbo, M.; Fusco, T.; Sauvage, J.-F.; Conan, J.-M.; Meimon, S.; Le Roux, B.

    2011-09-01

    Refined simulation tools for wide field AO systems (such as MOAO, MCAO or LTAO) on ELTs present new challenges. Increasing the number of degrees of freedom (scales as the square of the telescope diameter) makes the standard codes useless due to the huge number of operations to be performed at each step of the AO loop process. This computational burden requires new approaches in the computation of the DM voltages from WFS data. The classical matrix inversion and the matrix vector multiplication have to be replaced by a cleverer iterative resolution of the Least Square or Minimum Mean Square Error criterion (based on sparse matrices approaches). Moreover, for this new generation of AO systems, concepts themselves will become more complex: data fusion coming from multiple Laser and natural guide stars will have to be optimized, mirrors covering all the field of view associated to dedicated mirrors inside the scientific instrument itself will have to be coupled with split or integrated tomography schemes, differential pupil or/and field rotations will have to be considered, etc ... All these new entries should be carefully simulated, analysed and quantified in terms of performance before any implementation in AO systems. In this paper we present a new E2E simulator, developed to deal with all these specific ELT challenges. It is based on an iterative resolution of the linear model with high number of degrees of freedom (using the sparse matrix) and includes new concepts of filtering and coupling between LGS and NGS to effectively manage modes such as tip / tilt and defocus in the entire process of tomographic reconstruction. The first application of this tool in the frame of the EAGLE project, a flagship instrument of the future E-ELT combining all these issues, is presented.

  18. Wide field imager instrument for the Advanced Telescope for High Energy Astrophysics

    NASA Astrophysics Data System (ADS)

    Meidinger, Norbert; Nandra, Kirpal; Plattner, Markus; Porro, Matteo; Rau, Arne; Santangelo, Andrea; Tenzer, Chris; Wilms, Jörn

    2015-01-01

    The Advanced Telescope for High Energy Astrophysics (Athena) has been selected for ESA's L2 mission, scheduled for launch in 2028. It will provide the necessary capabilities to achieve the ambitious goals of the science theme "The Hot and Energetic Universe." Athena's x-ray mirrors will be based on silicon pore optics technology with a 12-m focal length. Two complementary focal plane camera systems are foreseen, which can be moved interchangeably to the focus of the mirror system: the actively shielded micro-calorimeter spectrometer X-IFU and the wide field imager (WFI). The WFI camera will provide an unprecedented survey power through its large field of view of 40 arc min with a high count-rate capability (˜1 Crab). It permits a state-of-the-art energy resolution in the energy band of 0.1 to 15 keV during the entire mission lifetime (e.g., full width at half maximum ≤150 eV at 6 keV). This performance is accomplished by a set of depleted P-channel field effect transistor (DEPFET) active pixel sensor matrices with a pixel size well suited to the angular resolution of 5 arc sec (on-axis) of the mirror system. Each DEPFET pixel is a combined detector-amplifier structure with a MOSFET integrated onto a fully depleted 450-μm-thick silicon bulk. This manuscript will summarize the current instrument concept and design, the status of the technology development, and the envisaged baseline performance.

  19. DC-like Phase Space Manipulation and Particle Acceleration Using Chirped AC Fields

    SciTech Connect

    P.F. Schmit and N.J. Fisch

    2009-06-17

    Waves in plasmas can accelerate particles that are resonant with the wave. A DC electric field also accelerates particles, but without a resonance discrimination, which makes the acceleration mechanism profoundly different. We investigate the effect on a Hamiltonian distribution of an accelerating potential waveform, which could, for example, represent the average ponderomotive effect of two counterpropagating electromagnetic waves. In particular, we examine the apparent DC-like time-asymptotic response of the distribution in regimes where the potential structure is accelerated adiabatically. A highly resonant population within the distribution is always present, and we characterize its nonadiabatic response during wave-particle resonance using an integral method in the noninertial reference frame moving with the wave. Finally, we show that in the limit of infinitely slow acceleration of the wave, these highly resonant particles disappear and the response

  20. Cooling Floor AC Systems

    NASA Astrophysics Data System (ADS)

    Jun, Lu; Hao, Ding; Hong, Zhang; Ce, Gao Dian

    The present HVAC equipments for the residential buildings in the Hot-summer-and-Cold-winter climate region are still at a high energy consuming level. So that the high efficiency HVAC system is an urgently need for achieving the preset government energy saving goal. With its advantage of highly sanitary, highly comfortable and uniform of temperature field, the hot-water resource floor radiation heating system has been widely accepted. This paper has put forward a new way in air-conditioning, which combines the fresh-air supply unit and such floor radiation system for the dehumidification and cooling in summer or heating in winter. By analyze its advantages and limitations, we found that this so called Cooling/ Heating Floor AC System can improve the IAQ of residential building while keep high efficiency quality. We also recommend a methodology for the HVAC system designing, which will ensure the reduction of energy cost of users.