Science.gov

Sample records for action leakage rate

  1. 40 CFR 264.252 - Action leakage rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Action leakage rate. 264.252 Section 264.252 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Waste Piles § 264.252 Action leakage rate. (a)...

  2. 40 CFR 265.222 - Action leakage rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Surface Impoundments § 265.222 Action leakage rate. (a) The owner or operator of surface...) The Regional Administrator shall approve an action leakage rate for surface impoundment units...

  3. 40 CFR 265.222 - Action leakage rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Surface Impoundments § 265.222 Action leakage rate. (a) The owner or operator of surface...) The Regional Administrator shall approve an action leakage rate for surface impoundment units...

  4. 40 CFR 264.222 - Action leakage rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Action leakage rate. 264.222 Section 264.222 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Surface Impoundments § 264.222 Action leakage...

  5. 40 CFR 265.302 - Action leakage rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 26 2011-07-01 2011-07-01 false Action leakage rate. 265.302 Section 265.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Landfills § 265.302 Action...

  6. 40 CFR 265.302 - Action leakage rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Action leakage rate. 265.302 Section 265.302 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Landfills § 265.302 Action...

  7. 40 CFR 265.222 - Action leakage rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Action leakage rate. 265.222 Section 265.222 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... system (LDS) can remove without the fluid head on the bottom liner exceeding 1 foot. The action...

  8. 40 CFR 265.222 - Action leakage rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Action leakage rate. 265.222 Section 265.222 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... system (LDS) can remove without the fluid head on the bottom liner exceeding 1 foot. The action...

  9. 40 CFR 265.222 - Action leakage rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Action leakage rate. 265.222 Section 265.222 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... system (LDS) can remove without the fluid head on the bottom liner exceeding 1 foot. The action...

  10. 40 CFR 264.252 - Action leakage rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Action leakage rate. 264.252 Section 264.252 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... flow rate that the leak detection system (LDS) can remove without the fluid head on the bottom...

  11. 40 CFR 264.252 - Action leakage rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Action leakage rate. 264.252 Section 264.252 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED... flow rate that the leak detection system (LDS) can remove without the fluid head on the bottom...

  12. 40 CFR 264.252 - Action leakage rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Waste... for waste pile units subject to § 264.251(c) or (d). The action leakage rate is the maximum design..., operation, and location of the LDS, waste and leachate characteristics, likelihood and amounts of...

  13. 40 CFR 264.252 - Action leakage rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Waste... for waste pile units subject to § 264.251(c) or (d). The action leakage rate is the maximum design..., operation, and location of the LDS, waste and leachate characteristics, likelihood and amounts of...

  14. 40 CFR 265.255 - Action leakage rates.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Action leakage rates. 265.255 Section 265.255 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) INTERIM STATUS STANDARDS FOR OWNERS AND OPERATORS OF HAZARDOUS WASTE TREATMENT, STORAGE, AND DISPOSAL FACILITIES Waste Piles § 265.255...

  15. 40 CFR 265.255 - Action leakage rates.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... daily flow rate for each sump must be calculated weekly during the active life and closure period....

  16. 40 CFR 265.255 - Action leakage rates.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... daily flow rate for each sump must be calculated weekly during the active life and closure period....

  17. 40 CFR 264.222 - Action leakage rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  18. 40 CFR 265.302 - Action leakage rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  19. 40 CFR 264.302 - Action leakage rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  20. 40 CFR 264.222 - Action leakage rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  1. 40 CFR 264.302 - Action leakage rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  2. 40 CFR 264.302 - Action leakage rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  3. 40 CFR 265.302 - Action leakage rate.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  4. 40 CFR 264.302 - Action leakage rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  5. 40 CFR 265.255 - Action leakage rates.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... daily flow rate for each sump must be calculated weekly during the active life and closure period....

  6. 40 CFR 264.302 - Action leakage rate.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  7. 40 CFR 265.302 - Action leakage rate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  8. 40 CFR 265.255 - Action leakage rates.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... layover and creep of synthetic components of the system, overburden pressures, etc.). (c) To determine if... daily flow rate for each sump must be calculated weekly during the active life and closure period....

  9. 40 CFR 264.222 - Action leakage rate.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  10. 40 CFR 264.222 - Action leakage rate.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and creep of synthetic components of the system, overburden pressures, etc.). (b) To determine if the... average daily flow rate for each sump must be calculated weekly during the active life and closure...

  11. Vacuum test fixture improves leakage rate measurements

    NASA Technical Reports Server (NTRS)

    Maier, H.; Marx, H.

    1966-01-01

    Cylindrical chamber, consisting of two matching halves, forms a vacuum test fixture for measuring leakage rates of individual connections, brazed joints, and entrance ports used in closed fluid flow line systems. Once the chamber has been sufficiently evacuated, atmospheric pressure holds the two halves together.

  12. Measurements of the atmospheric neutron leakage rate

    NASA Technical Reports Server (NTRS)

    Lockwood, J. A.; Ifedili, S. O.; Jenkins, R. W.

    1973-01-01

    The atmospheric neutron leakage rate in the energy range from 0.01 to 10,000,000 eV has been measured as a function of latitude, altitude, and time with a neutron detector on board the Ogo 6 satellite. The latitude dependence of the neutron leakage is in reasonable agreement with that predicted by Lingenfelter (1963) and Light et al. (1973) if the neutron energy spectrum has the shape calculated by Newkirk (1963). The change in the neutron latitude dependence with the cosmic ray modulation agrees with the predictions of Lingenfelter and Light et al. For several solar proton events enhancements were observed in the neutron counting rates at lambda greater than or equal to 70 deg. Such events, however, provide an insignificant injection of protons at E less than or equal to 20 MeV into the radiation belts. An isotropic angular distribution of the neutron leakage in the energy range from 0.1 keV to 10 MeV best fits the observed altitude dependence of the neutron leakage flux.

  13. Estimation of leakage rates through flexible membrane liners

    SciTech Connect

    Murray, G.B.; McBean, E.A.; Sykes, J.F.

    1995-12-31

    Leakage rate calculations for both low-permeability soil liners and composite liners using flexible membrane liners (FMLs) overlying low-permeability soil are developed. Latin-Hypercube simulations with uncertainty assigned to the soil liner hydraulic conductivity value and the spatial frequency of FML holes are used to examine the variability in the liner leakage rats. The low-permeability soil hydraulic conductivity is the parameter with the greatest effect on landfill liner leakages rates. Composite liners have a significant impact on reducing leakage rates through the landfill liner.

  14. A study of leakage rates through mine seals in underground coal mines

    PubMed Central

    Schatzel, Steven J.; Krog, Robert B.; Mazzella, Andrew; Hollerich, Cynthia; Rubinstein, Elaine

    2015-01-01

    The National Institute for Occupational Safety and Health conducted a study on leakage rates through underground coal mine seals. Leakage rates of coal bed gas into active workings have not been well established. New seal construction standards have exacerbated the knowledge gap in our understanding of how well these seals isolate active workings near a seal line. At a western US underground coal mine, we determined seal leakage rates ranged from about 0 to 0.036 m3/s for seven 340 kPa seals. The seal leakage rate varied in essentially a linear manner with variations in head pressure at the mine seals. PMID:26322119

  15. On the Fluid Leakage Rate and Pressure Evaluation of Abandoned Non-Penetrating Wells.

    NASA Astrophysics Data System (ADS)

    Islam, J.; Zhan, H.

    2014-12-01

    Understanding flow leakage through abandoned wells that are potential pathways of contamination due to injecting unwanted fluids in geologically deep storage aquifers have become an intensively investigated subject in the subsurface hydrology and petroleum engineering. This study represents a semi-analytical transient solution for estimating leakage rate by pressure change evaluation through an abandoned non-penetrating well (ANW) coupled with an injection well. The leakage rate can be estimated using the Darcy's law by evaluating pressure change between the upper and the lower aquifers through ANW. The analysis was conducted by solving the diffusivity equations of fluid flow in the aquifer coupled with the pipe flow through ANW. The single-phase flow is considered in this study that is capable of explaining both fluid and CO2 plume flow in an aquifer system by neglecting the variable density effect. The result is compared with that of Avci's (1994) which dealt with an abandoned fully penetrating well. The result indicates the similar type of curve trend, which is observed by applying a range of aquifer properties as well as distance between the injection and leakage pathway. The important finding is that the leakage rate through ANW is about 50% compared to the fully penetrating well of Avci's (1994). The sensitivity analyses indicate that parameter leakage coefficient (A), transmissivity ratio (TD) and radial distance (R) between injection and ANW are the most sensitive to the leakage rate and the rest of the parameters are less sensitive. Because of availability of limited analytical and complex numerical solution, this simple new approach is going to provide a simple means to estimate leakage flow for realistic field condition.

  16. Effect of vadose zone on the steady-state leakage rates from landfill barrier systems

    SciTech Connect

    Celik, B. Rowe, R.K. Unlue, K.

    2009-01-15

    Leakage rates are evaluated for a landfill barrier system having a compacted clay liner (CCL) underlain by a vadose zone of variable thickness. A numerical unsaturated flow model SEEP/W is used to simulate the moisture flow regime and steady-state leakage rates for the cases of unsaturated zones with different soil types and thicknesses. The results of the simulations demonstrate that harmonic mean hydraulic conductivity of coarse textured vadose zones is 3-4 orders of magnitude less than saturated hydraulic conductivity; whereas, the difference is only one order of magnitude for fine textured vadose zones. For both coarse and fine textured vadose zones, the effective hydraulic conductivity of the barrier system and the leakage rate to an underlying aquifer increases with increasing thickness of the vadose zone and ultimately reaches an asymptotic value for a coarse textured vadose zone thickness of about 10 m and a fine textured vadose zone thickness of about 5 m. Therefore, the fine and coarse textured vadose zones thicker than about 5 m and 10 m, respectively, act as an effective part of the barrier systems examined. Although the thickness of vadose zone affects the effective hydraulic conductivity of the overall barrier system, the results demonstrated that the hydraulic conductivity of the CCL is the dominant factor controlling the steady-state leakage rates through barrier systems having single low permeability clay layers.

  17. Vent and relief valve maintains low leakage rate over broad temperature range

    NASA Technical Reports Server (NTRS)

    Weitenbeck, R. G.

    1968-01-01

    Low leakage rate, large diameter vent and relief valve operates satisfactorily over a large temperature range by a design that accommodates waviness and distortions due to thermal gradients. It is based on a fixed sealing member having an inclined lapped surface to which a flexible flow gate conforms.

  18. Fluctuations and the Rate-Limiting Step of Peptide-Induced Membrane Leakage

    PubMed Central

    Mazzuca, C.; Orioni, B.; Coletta, M.; Formaggio, F.; Toniolo, C.; Maulucci, G.; De Spirito, M.; Pispisa, B.; Venanzi, M.; Stella, L.

    2010-01-01

    Peptide-induced vesicle leakage is a common experimental test for the membrane-perturbing activity of antimicrobial peptides. The leakage kinetics is usually very slow, requiring minutes to hours for complete release of vesicle contents, and exhibits a biphasic behavior. We report here that, in the case of the peptaibol trichogin GA IV, all processes involved in peptide-membrane interaction, such as peptide-membrane association, peptide aggregation, and peptide translocation, take place on a timescale much shorter than the leakage kinetics. On the basis of these findings, we propose a stochastic model in which the leakage kinetics is determined by the discrete nature of a vesicle suspension: peptides are continuously exchanging among vesicles, producing significant fluctuations over time in the number of peptide molecules bound to each vesicle, and in the formation of pores. According to this model, the fast initial leakage is caused by vesicles that contain at least one pore after the peptides are randomly distributed among the liposomes, whereas the slower release is associated with the time needed to occasionally reach in an intact vesicle the critical number of bound peptides necessary for pore formation. Fluctuations due to peptide exchange among vesicles therefore represent the rate-limiting step of such a slow mechanism. PMID:20858423

  19. Space Station Freedom delta pressure leakage rate comparison test data analysis report

    NASA Technical Reports Server (NTRS)

    Sorensen, E. B.

    1992-01-01

    Results are provided of a series of tests performed to identify the relationship between gas leakage rates across a seal at various internal to external pressure ratios. The results complement and provide insight into the analysis technique used to obtain the results presented in MSFC SSF/DEV/EL91-008, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study with Delta Pressure Leak Rate Comparison Test Report.'

  20. Decreased leakage rate of colonic anastomoses by tachosil coating: an experimental study.

    PubMed

    Pommergaard, Hans-Christian; Achiam, Michael Patrick; Burcharth, Jakob; Rosenberg, Jacob

    2014-01-01

    Colorectal anastomotic coating has been proposed as a means to lower the leakage rate. Prior to clinical testing, coating materials need thorough experimental evaluation to ensure safety and efficacy. The aim of this study was to evaluate Tachosil as an anastomotic coating agent. Technically insufficient colon anastomoses were created in 80 C57BL/6 mice, and in half of the animals the anastomoses were covered with Tachosil. The animals were examined for clinical signs of anastomotic leakage, and the breaking strength of the anastomoses was evaluated. The number of leakages was reduced by Tachosil coating (10/40 versus 20/40 in controls; P=0.037). However, more cases of large bowel obstruction were found in the Tachosil group (12/40 versus 0/40 in controls; P<0.0005). Breaking strength was comparable between the Tachosil and control groups (0.49 N versus 0.52 N, respectively; P=0.423). Clinical studies are needed to clarify the efficacy of Tachosil anastomotic coating. PMID:25058765

  1. Effects of saline-water flow rate and air speed on leakage current in RTV coatings

    SciTech Connect

    Kim, S.H.; Hackam, R.

    1995-10-01

    Room temperature vulcanizing (RTV) silicone rubber is increasingly being used to coat porcelain and glass insulators in order to improve their electrical performance in the presence of pollution and moisture. A study of the dependence of leakage current, pulse current count and total charge flowing across the surface of RTV on the flow rate of the saline water and on the compressed air pressure used to create the salt-fog is reported. The fog was directed at the insulating rods either from one or two sides. The RTV was fabricated from polydimethylsiloxane polymer, a filler of alumina trihydrate (ATH), a polymerization catalyst and fumed silica reinforcer, all dispersed in 1,1,1-trichloroethane solvent. The saline water flow rate was varied in the range 0.4 to 2.0 l/min. The compressed air pressure at the input of the fog nozzles was varied from 0.20 to 0.63 MPa. The air speed at the surface of the insulating rods was found to depend linearly on the air pressure measured at the inlet to the nozzles and varied in the range 3 to 14 km/hr. The leakage current increased with increasing flow rate and increasing air speed. This is attributed to the increased loss of hydrophobicity with a larger quantity of saline fog and a larger impact velocities of fog droplets interacting with the surface of the RTV coating.

  2. Methane leakage from evolving petroleum systems: Masses, rates and inferences for climate feedback

    NASA Astrophysics Data System (ADS)

    Berbesi, L. A.; di Primio, R.; Anka, Z.; Horsfield, B.; Wilkes, H.

    2014-02-01

    The immense mass of organic carbon contained in sedimentary systems, currently estimated at 1.56×1010 Tg (Des Marais et al., 1992), bears the potential of affecting global climate through the release of thermally or biologically generated methane to the atmosphere. Here we investigate the potential of naturally-occurring gas leakage, controlled by petroleum generation and degradation as a forcing mechanism for climate at geologic time scales. We addressed the potential methane contributions to the atmosphere during the evolution of petroleum systems in two different, petroliferous geological settings: the Western Canada Sedimentary Basin (WCSB) and the Central Graben area of the North Sea. Besides 3D numerical simulation, different types of mass balance and theoretical approaches were applied depending on the data available and the processes taking place in each basin. In the case of the WCSB, we estimate maximum thermogenic methane leakage rates in the order of 10-2-10-3 Tg/yr, and maximum biogenic methane generation rates of 10-2 Tg/yr. In the case of the Central Graben, maximum estimates for thermogenic methane leakage are in the order in 10-3 Tg/yr. Extrapolation of our results to a global scale suggests that, at least as a single process, thermal gas generation in hydrocarbon kitchen areas would not be able to influence climate, although it may contribute to a positive feedback. Conversely, only the sudden release of subsurface methane accumulations, formed over geologic timescales, can possibly allow for petroleum systems to exert an effect on climate.

  3. Space Station Freedom seal leakage rate analysis and testing summary: Air leaks in ambient versus vacuum exit conditions

    NASA Technical Reports Server (NTRS)

    Rodriguez, P. I.; Markovitch, R.

    1992-01-01

    This report is intended to reveal the apparent relationship of air seal leakage rates between 2 atmospheres (atm) to 1 atm and 1 atm to vacuum conditions. Gas dynamics analysis is provided as well as data summarizing the MSFC test report, 'Space Station Freedom (S.S. Freedom) Seal Flaw Study With Delta Pressure Leak Rate Comparison Test Report'.

  4. SU-E-T-628: Effect of Dose Rate and Leakage Correction for Dosimetric Leaf Gap Measurement

    SciTech Connect

    Feng, W; Chu, A; Chi, Y; Hu, J

    2014-06-15

    Purpose: To study the dose rate response of Mapcheck and quantify/correct dose rate/leakage effect on IMRT QA. Evaluate the dose rate/leakage effect on dosimetric leaf gap (DLG) measurement. Methods: Varian Truebeam Linac with HD120 MLC was used for all measurement, it is capable to adjust dose rate from 600MU/min to 5MU/min. Fluke Advanced Therapy Doisemter and PTW 30013 Farmer chamber for chamber measurement; SunNuclear Mapcheck2 with 5cm total buildup for diode measurement. DLG was measured with both chamber and diode.Diode response was measured by varies dose rate, while fixed mapcheck setup and total MU. MLC Leakage was measured with both chamber and diode. Mapcheck measurement was saved as movie file (mcm file), which include measurement updated every 50mSec. The difference between intervals can be converted to dose and dose rate and leakage response correction can be applied to them. Results: DLG measurement results with chamber and diode were showed as follows, the DLG value is 0.36 vs. 0.24mm respectively. Diode dose rate response drops from 100% at 600MU/min to 95.5% at 5MU/min as follows. MLC Leakage measured with diode is 1.021%, which is 9% smaller than 1.112% from chamber measurement. By apply the dose rate and leakage correction, the residue error reduced 2/3. Conclusions: Diode has lower response at lower dose rate, as low as 4.5% for 5MU/min; diode has lower energy response for low energy too, 5% lower for Co-60 than 6MV. It partially explains the leakage difference of 9% between chamber and diode. Lower DLG with diode is because of the lower response at narrower gap, in Eclipse however DLG need to increase to makeup lower response, which is over correction for chamber though. Correction can reduce error by 2/3, the rest 1/3 can be corrected by scatter effect, which is under study.

  5. Comparison of hydraulic and chemical methods for determining hydraulic conductivity and leakage rates in argillaceous aquitards

    NASA Astrophysics Data System (ADS)

    Batlle-Aguilar, Jordi; Cook, Peter G.; Harrington, Glenn A.

    2016-01-01

    The capacity of argillaceous aquitards to effectively separate fresh water aquifers from lower quality waters has been widely studied for several decades using both hydraulic and chemical methods. Hydraulic methods, namely laboratory, field and regional groundwater flow modelling, are used to estimate hydraulic conductivity (K), whereas chemical methods, namely aquitard porewater and aquifer groundwater chemistry, are used to estimate either leakage rates or porewater velocity (V). We reviewed a total of 40 formations where either K or V (or both) have been estimated. Typical vertical hydraulic conductivity (KZ) values in argillaceous materials estimated using hydraulic methods are 10-12-10-9 m s-1. Usual V values, estimated using chemical methods, ranges between 0.01 and 1 mm y-1, although the range is as wide as 10-4-103 mm y-1, when inferred from hydraulic KZ measurements. Based on a Péclet number of 1, we calculated the lower limits of porewater velocity that can be reliably identified for different tracers, in most cases ranging from <1 mm y-1 for 2H, 18O and Cl- to >100 mm y-1 for temperature. Despite the limited number of sites where both methods were applied, comparison between hydraulic and chemical-derived values showed a reasonable correlation, although the range of KZ and V estimated using hydraulic methods is larger than that obtained using chemical methods. Methods applied to the whole aquitard thickness (some field hydraulic methods, regional groundwater flow modelling, aquitard porewater and aquifer chemistry) consistently result in lower KZ values, most probably indicating the presence of very low KZ layers within the aquitard, likely to be missed while using field hydraulic methods that test only a section of the entire thickness. KZ was observed to decrease with depth, presumably due to an increase in consolidation resulting in loss of porosity and smaller aperture of fractures and joints. Multi-disciplinary studies involving the use of

  6. Decreased Rate of CSF Leakage Associated with Complete Reconstruction of Suboccipital Cranial Defects

    PubMed Central

    Stoker, Michael A.; Forbes, Jonathan A.; Hanif, Rimal; Cooper, Calvin; Nian, Hui; Konrad, Peter E.; Neimat, Joseph S.

    2012-01-01

    Background Cerebrospinal fluid (CSF) leakage represents a major source of morbidity following microvascular decompression (MVD) surgery. The objective of this study was to retrospectively assess whether complete versus incomplete reconstruction of the suboccipital cranial defect influences the incidence of CSF leakage following MVD. Methods We reviewed the charts of 100 patients who consecutively underwent MVD for trigeminal neuralgia by two attending neurosurgeons between July 2004 and April 2010. Operative variables including incomplete or complete calvarial reconstruction, primary dural closure or dural closure with adjunct, and use of lumbar drainage were recorded. The effect of complete calvarial reconstruction on the incidence of postoperative CSF leakage was examined using a multivariate logistic regression model. Results Of the 36 patients whose wound closure was reconstructed with a complete cranioplasty, 2 (5.6%) patients experienced a postoperative CSF leak. Of the 64 patients whose wound closure was augmented with an incomplete cranioplasty, 15 (23.4%) experienced a postoperative CSF leak. There was suggestive but inconclusive evidence that the risk of CSF leakage following MVD was smaller with complete reconstruction of calvarial defect than with incomplete reconstruction (two-sided p value = 0.059), after accounting for age, dural closure method, use of lumbar drainage, and previous MVD. Conclusion Complete reconstruction of the suboccipital cranial defect decreases the risk of CSF leakage. PMID:23905005

  7. Transanal drainage tube reduces rate and severity of anastomotic leakage in patients with colorectal anastomosis: A case controlled study

    PubMed Central

    Brandl, A.; Czipin, S.; Mittermair, R.; Weiss, S.; Pratschke, J.; Kafka-Ritsch, R.

    2016-01-01

    Background and aims The aim of this study was to investigate the clinical usefulness of the placement of a transanal drainage tube to prevent anastomotic leakage in colorectal anastomoses. Material and methods This single-center retrospective trial included all patients treated with surgery for benign or malign colorectal disease between January 2009 and December 2012. The transanal drainage tube was immediately placed after colorectal anastomosis until day five and was routinely used since 2010. Patients treated with a transanal drainage tube were compared with the control group. Statistical analysis was performed using Fisher's exact or Chi-square tests for group comparison and a linear regression model for multivariate analysis. Results This study included 242 patients (46% female; median age 63 years; range 18–93); 34% of the patients underwent a laparoscopic procedure, and 57% of the patients received a placement of a transanal drainage tube. Anastomotic leakage occurred in 19 patients (7.9%). Univariate analysis showed a higher rate of anastomotic leakage in patients with an ASA score 4 (p = 0.02) and a lower rate in patients with transanal drainage placement (3.6% vs. 13.6%; p = 0.007). The grading of the complication of anastomotic leakage was reduced with transanal drainage (e.g., Dindo ≧ 3b: 20.0% vs. 92.9%; p = 0.006), and the hospital stay was shortened (17.6 ± 12.5 vs. 22.1 ± 17.6 days; p = 0.02). Multivariate analysis revealed that transanal drainage was the only significant factor (HR = −2.90; −0.168 to −0.032; p = 0.007) affecting anastomotic leakage. Conclusions Placement of a transanal drainage tube in patients with colorectal anastomoses is a safe and simple technique to perform and reduces anastomotic leakage, the severity of the complication and hospital stay. PMID:27158483

  8. Thermal-hydraulic analysis for changing feedwater check valve leakage rate testing methodology

    SciTech Connect

    Fuller, R.; Harrell, J.

    1996-12-01

    The current design and testing requirements for the feedwater check valves (FWCVs) at the Grand Gulf Nuclear Station are established from original licensing requirements that necessitate extremely restrictive air testing with tight allowable leakage limits. As a direct result of these requirements, the original high endurance hard seats in the FWCVs were modified with elastomeric seals to provide a sealing surface capable of meeting the stringent air leakage limits. However, due to the relatively short functional life of the elastomeric seals compared to the hard seats, the overall reliability of the sealing function actually decreased. This degraded performance was exhibited by frequent seal failures and subsequent valve repairs. The original requirements were based on limited analysis and the belief that all of the high energy feedwater vaporized during the LOCA blowdown. These phenomena would have resulted in completely voided feedwater lines and thus a steam environment within the feedwater leak pathway. To challenge these criteria, a comprehensive design basis accident analysis was developed using the RELAP5/MOD3.1 thermal-hydraulic code. Realistic assumptions were used to more accurately model the post-accident fluid conditions within the feedwater system. The results of this analysis demonstrated that no leak path exists through the feedwater lines during the reactor blowdown phase and that sufficient subcooled water remains in various portions of the feedwater piping to form liquid water loop seals that effectively isolate this leak path. These results provided the bases for changing the leak testing requirements of the FWCVs from air to water. The analysis results also established more accurate allowable leakage limits, determined the real effective margins associated with the FWCV safety functions, and led to design changes that improved the overall functional performance of the valves.

  9. Cobalt chloride attenuates hypobaric hypoxia induced vascular leakage in rat brain: Molecular mechanisms of action of cobalt chloride

    SciTech Connect

    Kalpana, S.; Dhananjay, S.; Anju, B. Lilly, G.; Sai Ram, M.

    2008-09-15

    This study reports the efficacy of cobalt preconditioning in preventing hypobaric hypoxia induced vascular leakage (an indicator of cerebral edema) using male Sprague-Dawley rats as model system. Exposure of animals to hypobaric hypoxia led to a significant increase in vascular leakage, reactive oxygen species (ROS), nitric oxide (NO), and vascular endothelial growth factor (VEGF) levels. There was a marked increase in Nuclear Factor {kappa}B (NF{kappa}B) DNA binding activity and levels of pro-inflammatory cytokines such as Monocyte chemoattractant protein (MCP-1), Interferon-{gamma} (IFN-{gamma}), Interleukin-1 (IL-1), and Tumor Necrosis Factor-{alpha} (TNF-{alpha}) and cell adhesion molecules such as Vascular Cell Adhesion Molecule-1 (VCAM-1), and P-selectin. Chemical preconditioning by cobalt for 7 days (12.5 mg Co/kg b.w., oral) significantly attenuated cerebral vascular leakage and the expression of inflammatory mediators induced by hypoxia. Administration of NF{kappa}B inhibitor, curcumin (50 mg/kg b.w.; i.p.) appreciably inhibited hypoxia induced vascular leakage indicating the involvement of NF{kappa}B in causing vascular leakage. Interestingly, cobalt when administered at 12.5 mg Co/kg b.w. (i.p.), 1 h before hypoxia could not prevent the vascular leakage indicating that cobalt per se did not have an effect on NF{kappa}B. The lower levels of NF{kappa}B observed in the brains of cobalt administered animals might be due to higher levels of antioxidant and anti-inflammatory proteins (hemeoxygenase-1 and metallothionein). To conclude cobalt preconditioning inhibited hypobaric hypoxia induced cerebral vascular leakage by lowering NF{kappa}B DNA binding activity and its regulated pro-inflammatory mediators. This is contemplated to be mediated by cobalt induced reduction in ROS/NO and increase in HO-1 and MT.

  10. Quantifying Molecular Hydrogen Emissions and an Industrial Leakage Rate for the South Coast Air Basin of California

    NASA Astrophysics Data System (ADS)

    Irish, M. C.; Schroeder, J.; Beyersdorf, A. J.; Blake, D. R.

    2015-12-01

    The poorly understood atmospheric budget and distribution of molecular hydrogen (H2) have invited further research since the discovery that emissions from a hydrogen-based economy could have negative impacts on the global climate system and stratospheric ozone. The burgeoning fuel cell electric vehicle industry in the South Coast Air Basin of California (SoCAB) presents an opportunity to observe and constrain urban anthropogenic H2 emissions. This work presents the first H2 emissions estimate for the SoCAB and calculates an upper limit for the current rate of leakage from production and distribution infrastructure within the region. A top-down method utilized whole air samples collected during the Student Airborne Research Program (SARP) onboard the NASA DC-8 research aircraft from 23-25 June 2015 to estimate H2 emissions from combustion and non-combustion sources. H2:carbon monoxide (CO) and H2:carbon dioxide ratios from airborne observations were compared with experimentally established ratios from pure combustion source ratios and scaled with the well-constrained CO emissions inventory to yield H2 emissions of 24.9 ± 3.6 Gg a-1 (1σ) from combustion engines and 8.2 ± 4.7 Gg a-1 from non-combustion sources. Total daily production of H2 in the SoCAB was compared with the top-down results to estimate an upper limit leakage rate (5%) where all emissions not accounted for by incomplete combustion in engines were assumed to be emitted from H2 infrastructure. For bottom-up validation, the NOAA Hybrid Single Particle Lagrangian Integrated Trajectory dispersion model was run iteratively with all known stationary sources in attempt to constrain emissions. While this investigation determined that H2 emissions from non-combustion sources in the SoCAB are likely significant, more in-depth analysis is required to better predict the atmospheric implications of a hydrogen economy.

  11. Land-use Leakage

    SciTech Connect

    Calvin, Katherine V.; Edmonds, James A.; Clarke, Leon E.; Bond-Lamberty, Benjamin; Kim, Son H.; Wise, Marshall A.; Thomson, Allison M.; Kyle, G. Page

    2009-12-01

    Leakage occurs whenever actions to mitigate greenhouse gas emissions in one part of the world unleash countervailing forces elsewhere in the world so that reductions in global emissions are less than emissions mitigation in the mitigating region. While many researchers have examined the concept of industrial leakage, land-use policies can also result in leakage. We show that land-use leakage is potentially as large as or larger than industrial leakage. We identify two potential land-use leakage drivers, land-use policies and bioenergy. We distinguish between these two pathways and run numerical experiments for each. We also show that the land-use policy environment exerts a powerful influence on leakage and that under some policy designs leakage can be negative. International “offsets” are a potential mechanism to communicate emissions mitigation beyond the borders of emissions mitigating regions, but in a stabilization regime designed to limit radiative forcing to 3.7 2/m2, this also implies greater emissions mitigation commitments on the part of mitigating regions.

  12. 40 CFR 265.224 - Response actions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow rate into the leak detection system exceeds the...

  13. 40 CFR 265.224 - Response actions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow rate into the leak detection system exceeds the...

  14. 40 CFR 265.224 - Response actions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow rate into the leak detection system exceeds the...

  15. Quantifying canal leakage rates using a mass-balance approach and heat-based hydraulic conductivity estimates in selected irrigation canals, western Nebraska, 2007 through 2009

    USGS Publications Warehouse

    Hobza, Christopher M.; Andersen, Michael J.

    2010-01-01

    The water supply in areas of the North Platte River Basin in the Nebraska Panhandle has been designated as fully appropriated or overappropriated by the Nebraska Department of Natural Resources (NDNR). Enacted legislation (Legislative Bill 962) requires the North Platte Natural Resources District (NPNRD) and the NDNR to develop an Integrated Management Plan (IMP) to balance groundwater and surface-water supply and demand in the NPNRD. A clear understanding of the groundwater and surface-water systems is critical for the development of a successful IMP. The primary source of groundwater recharge in parts of the NPNRD is from irrigation canal leakage. Because canal leakage constitutes a large part of the hydrologic budget, spatially distributing canal leakage to the groundwater system is important to any management strategy. Surface geophysical data collected along selected reaches of irrigation canals has allowed for the spatial distribution of leakage on a relative basis; however, the actual magnitude of leakage remains poorly defined. To address this need, the U.S. Geological Survey, in cooperation with the NPNRD, established streamflow-gaging stations at upstream and downstream ends from two selected canal reaches to allow a mass-balance approach to be used to calculate daily leakage rates. Water-level and sediment temperature data were collected and simulated at three temperature monitoring sites to allow the use of heat as a tracer to estimate the hydraulic conductivity of canal bed sediment. Canal-leakage rates were estimated by applying Darcy's Law to modeled vertical hydraulic conductivity and either the estimated or measured hydraulic gradient. This approach will improve the understanding of the spatial and temporal variability of canal leakage in varying geologic settings identified in capacitively coupled resistivity surveys. The high-leakage potential study reach of the Tri-State Canal had two streamflow-gaging stations and two temperature monitoring

  16. Using Sulfur Hexafluoride to Quantify the Gas Leakage Rate within the Landscape Evolution Observatory (LEO) and the Diffusion Coefficient of the Crushed Basalt

    NASA Astrophysics Data System (ADS)

    Barta, J.; Costa, M.; Van Haren, J. L. M.; Pangle, L. A.; Troch, P. A. A.

    2014-12-01

    In order to understand the biological processes taking place on an experimental hillslope with vegetation, it is important to know the amount of gasses such as oxygen and carbon dioxide being produced and consumed. When studying the gas exchange rates in a closed system like the Landscape Evolution Observatory (LEO), one must take into account gas that is being lost or gained from other sources. Aside from biogeochemical processes, gas concentrations in the LEO atmosphere may change due to leakage to the outside environment and diffusion into the soil. To quantify these fluxes, two constants must be determined experimentally: the gas leakage constant L and the coefficient of diffusion for the hillslope soil. To accomplish this, a tracer gas, sulfur hexafluoride, was injected into the sealed east bay chamber and syringes were used to take samples periodically from the airspace and from the hillslope soil. The relative sulfur hexafluoride concentrations were then analyzed with a SRI 8610c gas chromatograph. By analyzing both the the airspace concentration decay as well as the concentration in the soil, the chamber's leakage constant was determined to be and the soil diffusion coefficient was also determined. Once these values are experimentally quantified, they can be used in equations to quantify the rate of gas leakage and soil diffusion of more important gases such as carbon dioxide and oxygen.

  17. 40 CFR 265.303 - Response actions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....301(a) must develop and keep on site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  18. 40 CFR 264.304 - Response actions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow...

  19. 40 CFR 265.259 - Response actions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... § 265.254 must develop and keep on-site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  20. 40 CFR 264.223 - Response actions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 264.221 (c) or (d) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section....

  1. 40 CFR 265.259 - Response actions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... § 265.254 must develop and keep on-site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  2. 40 CFR 265.259 - Response actions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... § 265.254 must develop and keep on-site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  3. 40 CFR 264.253 - Response actions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) or (d) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the...

  4. 40 CFR 265.259 - Response actions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... § 265.254 must develop and keep on-site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  5. 40 CFR 264.223 - Response actions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 264.221 (c) or (d) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section....

  6. 40 CFR 264.304 - Response actions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow...

  7. 40 CFR 264.304 - Response actions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow...

  8. 40 CFR 264.223 - Response actions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... § 264.221 (c) or (d) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section....

  9. 40 CFR 265.259 - Response actions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... § 265.254 must develop and keep on-site until closure of the facility a response action plan. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of...

  10. 40 CFR 264.304 - Response actions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow...

  11. 40 CFR 264.304 - Response actions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) must have an approved response action plan before receipt of waste. The response action plan must set forth the actions to be taken if the action leakage rate has been exceeded. At a minimum, the response action plan must describe the actions specified in paragraph (b) of this section. (b) If the flow...

  12. Semi-analytical solution for pressure change and leakage rate through aquifer leaks or fractures considering both Darcy and non-Darcy phenomena

    NASA Astrophysics Data System (ADS)

    Islam, J.; Zhan, H.

    2013-12-01

    Study of potential leakage of hazardous liquid waste into deep aquifer or abandoned wells is very important research work in recent days. CO2 sequestration into the brine media is not an exception of that. The saline aquifer is always overlain by a leaky aquitard or seal which may allow the migration of the injected CO2 or any kind of hazardous liquid waste to the upper aquifer through some leaks or fractures. The scope of study includes how the migration through the seal or aquitard causes the pressure change in the upper aquifer because of that injection into the target storage aquifer. Such pressure change is used to infer the leakage pathway location and characteristics of the leak or fractures. In this complex issue both Darcian and non-Darcian flow has been taken care of combindly. The Izbash equation has been used to describe the non-Darcian flow in the aquifer. A semi-analytical solution is obtained in Laplace domain and finally it has been solved numerically. Afterwards different parameters have been evaluated (leak or fracture size, injection rate, conductivity) to see how they directly affect the upper aquifer pressure and leakage rate independently.

  13. Augmented PMMA distribution: improvement of mechanical property and reduction of leakage rate of a fenestrated pedicle screw with diameter-tapered perforations.

    PubMed

    Tan, Quan-Chang; Wu, Jian-Wei; Peng, Fei; Zang, Yuan; Li, Yang; Zhao, Xiong; Lei, Wei; Wu, Zi-Xiang

    2016-06-01

    OBJECTIVE This study investigated the optimum injection volume of polymethylmethacrylate (PMMA) to augment a novel fenestrated pedicle screw (FPS) with diameter-tapered perforations in the osteoporotic vertebral body, and how the distribution characteristics of PMMA affect the biomechanical performance of this screw. METHODS Two types of FPSs were designed (FPS-A, composed of 6 perforations with an equal diameter of 1.2 mm; and FPS-B, composed of 6 perforations each with a tapered diameter of 1.5 mm, 1.2 mm, and 0.9 mm from tip to head. Each of 28 human cadaveric osteoporotic vertebrae were randomly assigned to 1 of 7 groups: FPS-A1.0: FPS-A+1.0 ml PMMA; FPS-A1.5: FPS-A+1.5 ml PMMA; FPS-A2.0: FPS-A+2.0 ml PMMA; FPS-B1.0: FPS-B+1.0 ml PMMA; FPS-B1.5: FPS-B+1.5 ml PMMA; FPS-B2.0: FPS-B+2.0 ml PMMA; and conventional pedicle screws (CPSs) without PMMA. After the augmentation, 3D CT was performed to assess the cement distribution characteristics and the cement leakage rate. Axial pullout tests were performed to compare the maximum pullout force thereafter. RESULTS The CT construction images showed that PMMA bone cement formed a conical mass around FPS-A and a cylindrical mass around FPS-B. When the injection volume was increased from 1.0 ml to 2.0 ml, the distribution region of the PMMA cement was enlarged, the PMMA was distributed more posteriorly, and the risk of leakage was increased. When the injection volume reached 2.0 ml, the risk of cement leakage was lower for screws having diameter-tapered perforations. The pullout strengths of the augmented FPS-A groups and FPS-B groups were higher than that of the CPS group (p < 0.0001). All FPS-B groups had a higher pullout strength than the FPS-A groups. CONCLUSIONS The diameter of the perforations affects the distribution of PMMA cement. The diameter-tapered design enabled PMMA to form larger bone-PMMA interfaces and achieve a relatively higher pullout strength, although statistical significance was not reached. Study

  14. Leakage currents in SOI MOSFETS

    SciTech Connect

    Annamala, N.K.; Biwer, M.C.

    1988-12-01

    Total dose response of both NMOS and PMOS FETs fabricated on SOI substrates was studied. Two types of back-channel leakage currents were identified. A back-channel leakage due to MOSFET action uses the substrate bias as the gate bias. The other component is due to soft reverse characteristics of the body-drain junction. The back-channel leakage due to MOSFET action varies with the substrate bias and hence varies with irradiation due to threshold voltage shift. The soft reverse characteristics are a function of drain-body voltage and hence vary with substrate bias and irradiation. I-V characteristics and subthreshold currents of both front and back channels as a function of total dose were obtained.

  15. Flows with tip leakage

    NASA Astrophysics Data System (ADS)

    Moore, John

    The flow development within the tip gap and the flow tip leakage, applying Navier-Stokes codes, are discussed. The loss production, the turbine inefficiency and the heat transfer to the blade tip, are considered. The measurements and calculations used demonstrate features of the flow, such as separation and reattachment on the blade tip, shock formation in the tip gap, and formation and dissipation of tip gap secondary kinetic energy. A procedure for calculating turbine blade tip temperatures is included. The results for a centrifugal compressor show the interaction of the tip leakage and passage flows. The radial blackflow near the shroud wall at low off-design flow rates is considered. The calculations demonstrate the potential use of a computational fluid dynamics code for predicting a centrifugal compressor map.

  16. Rates of Student Disciplinary Action in Australian Universities

    ERIC Educational Resources Information Center

    Lindsay, Bruce

    2010-01-01

    Although a growing body of research has been conducted on student misconduct in universities, quantitative data on disciplinary action undertaken by institutions against student transgressions are largely absent from the literature. This paper provides baseline quantitative data on disciplinary action against students in the universities. It is…

  17. Evaluating effective reaction rates of kinetically driven solutes in large-scale, anisotropic media: human health risk implications in CO2 leakage

    NASA Astrophysics Data System (ADS)

    Siirila, E. R.; Maxwell, R. M.

    2011-12-01

    The role of high and low hydraulic conductivity (K) regions in heterogeneous, stratified and non-stratified flow fields and the subsequent effect of rate dependent geochemical reactions are investigated with regards to mobilized arsenic from CO2 leakage at a Carbon Capture and Storage (CCS) site. Following the methodology of previous work, human health risk is used as an endpoint for comparison via a two-stage or nested Monte Carlo scheme, explicitly considering joint uncertainty and variability for a hypothetical population of individuals. This study identifies geo-hydrologic conditions where solute reactions are either rate limited (non-reactive), in equilibrium (linear equilibrium assumption, LEA, is appropriate), or are sensitive to time-dependent kinetic reaction rates. Potential interplay between multiple parameters (i.e. positive or negative feedbacks) is shown utilizing stochastic ensembles. In particular, the effect of preferential flow pathways and solute mixing on the field-scale (macrodispersion) and sub-grid (local dispersion) is examined for varying degrees of stratification and regional groundwater velocities. Results show effective reaction rates of kinetic ensembles are dissimilar from LEA ensembles with the inclusion of local dispersion, resulting in an additive tailing effect of the solute plume, a retarded peak time, and an increased cancer risk. This discrepancy between kinetic and LEA ensembles is augmented in highly anisotropic media, especially at intermediate regional groundwater velocities. The distribution, magnitude, and associated uncertainty of cancer risk are controlled by these factors, but are also strongly dependent on the regional groundwater velocity. We demonstrate a higher associated uncertainty of cancer risk in stratified domains is linked to higher aquifer connectivity and less macrodispersion in the flow field. This study has implications in CCS site selection and groundwater driven risk assessment modeling.

  18. 38 CFR 17.162 - Eligibility for Class II dental treatment without rating action.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... dental treatment without rating action. 17.162 Section 17.162 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Dental Services § 17.162 Eligibility for Class II dental treatment without rating action. When an application has been made for class II dental treatment under §...

  19. 38 CFR 17.162 - Eligibility for Class II dental treatment without rating action.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... dental treatment without rating action. 17.162 Section 17.162 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Dental Services § 17.162 Eligibility for Class II dental treatment without rating action. When an application has been made for class II dental treatment under §...

  20. Robust characterization of leakage errors

    NASA Astrophysics Data System (ADS)

    Wallman, Joel J.; Barnhill, Marie; Emerson, Joseph

    2016-04-01

    Leakage errors arise when the quantum state leaks out of some subspace of interest, for example, the two-level subspace of a multi-level system defining a computational ‘qubit’, the logical code space of a quantum error-correcting code, or a decoherence-free subspace. Leakage errors pose a distinct challenge to quantum control relative to the more well-studied decoherence errors and can be a limiting factor to achieving fault-tolerant quantum computation. Here we present a scalable and robust randomized benchmarking protocol for quickly estimating the leakage rate due to an arbitrary Markovian noise process on a larger system. We illustrate the reliability of the protocol through numerical simulations.

  1. 40 CFR 91.324 - Analyzer leakage check.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the...

  2. 40 CFR 91.324 - Analyzer leakage check.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the...

  3. 40 CFR 91.324 - Analyzer leakage check.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the...

  4. 40 CFR 91.324 - Analyzer leakage check.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the...

  5. 40 CFR 91.324 - Analyzer leakage check.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the...

  6. Report of the Build Subsidized Child Care Rate Policy Task Force: Recommendations for Action

    ERIC Educational Resources Information Center

    Stoney, Louise

    2004-01-01

    In the Fall of 2003, the Pennsylvania Build Initiative convened a Rate Policy Task Force to broadly examine the issue of child care rates and make recommendations for action. The Task Force goal was two-fold: (1) to suggest ways that the rate and payment process currently used by the Pennsylvania Department of Public Welfare (DPW) can better…

  7. Reserves in Context: Planning for Leakage from Protected Areas

    PubMed Central

    Renwick, Anna R.; Bode, Michael; Venter, Oscar

    2015-01-01

    When protected areas reduce threats within their boundaries, they often displace a portion of these threats into adjacent areas through a process known as ‘leakage’, undermining conservation objectives. Using theoretical models and a case study of terrestrial mammals in Indonesia, we develop the first theoretical explanation of how leakage impacts conservation actions, and highlight conservation strategies that mitigate these impacts. Although leakage is a socio-economic process, we demonstrate that its negative impacts are also affected by the distribution of species, with leakage having larger impacts in landscapes with homogeneous distribution of species richness. Moreover, leakage has a greater negative effect when conservation strategies are implemented opportunistically, even creating the potential for perversely negative consequences from protected area establishment. Leakage thereby increases the relative benefits of systematic conservation planning over opportunism, especially in areas with high leakage and heterogeneously distributed species. Although leakage has the potential to undermine conservation actions, conservation planning can minimize this risk. PMID:26053163

  8. Action Recognition Using Rate-Invariant Analysis of Skeletal Shape Trajectories.

    PubMed

    Ben Amor, Boulbaba; Su, Jingyong; Srivastava, Anuj

    2016-01-01

    We study the problem of classifying actions of human subjects using depth movies generated by Kinect or other depth sensors. Representing human body as dynamical skeletons, we study the evolution of their (skeletons’) shapes as trajectories on Kendall’s shape manifold. The action data is typically corrupted by large variability in execution rates within and across subjects and, thus, causing major problems in statistical analyses. To address that issue, we adopt a recently-developed framework of Su et al. [1], [2] to this problem domain. Here, the variable execution rates correspond to re-parameterizations of trajectories, and one uses a parameterization-invariant metric for aligning, comparing, averaging, and modeling trajectories. This is based on a combination of transported square-root vector fields (TSRVFs) of trajectories and the standard Euclidean norm, that allows computational efficiency. We develop a comprehensive suite of computational tools for this application domain: smoothing and denoising skeleton trajectories using median filtering, up- and down-sampling actions in time domain, simultaneous temporal-registration of multiple actions, and extracting invertible Euclidean representations of actions. Due to invertibility these Euclidean representations allow both discriminative and generative models for statistical analysis. For instance, they can be used in a SVM-based classification of original actions, as demonstrated here using MSR Action-3D, MSR Daily Activity and 3D Action Pairs datasets. Using only the skeletal information, we achieve state-of-the-art classification results on these datasets. PMID:27030844

  9. 24 CFR 985.107 - Required actions for PHA with troubled performance rating.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... administrative fee reserve for other housing purposes (see 24 CFR 982.155(b)). (f) Upgrading poor performance... troubled performance rating. 985.107 Section 985.107 Housing and Urban Development Regulations Relating to... § 985.107 Required actions for PHA with troubled performance rating. (a) On-site reviews—(1)...

  10. 49 CFR 385.17 - Change to safety rating based upon corrective actions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... (a) A motor carrier that has taken action to correct the deficiencies that resulted in a proposed or final rating of “conditional” or “unsatisfactory” may request a rating change at any time. (b) A motor...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER...

  11. 49 CFR 385.17 - Change to safety rating based upon corrective actions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    .... (a) A motor carrier that has taken action to correct the deficiencies that resulted in a proposed or final rating of “conditional” or “unsatisfactory” may request a rating change at any time. (b) A motor...) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER...

  12. Predicting Leakage in Labyrinth Seals

    NASA Technical Reports Server (NTRS)

    Morrison, G. L.; Rhode, D. L.; Cogan, K. C.; Chi, D.; Demko, J.

    1985-01-01

    Analytical and empirical methods evaluated. 264-page report presents comprehensive information on leakage in labyrinth seals. Summarizes previous analyses of leakage, reviews leakage tests conducted by authors and evaluates various analytical and experimental methods of determining leakage and discusses leakage prediction techniques.

  13. Shroud leakage flow discouragers

    DOEpatents

    Bailey, Jeremy Clyde; Bunker, Ronald Scott

    2002-01-01

    A turbine assembly includes a plurality of rotor blades comprising a root portion, an airfoil having a pressure sidewall and a suction sidewall, and a top portion having a cap. An outer shroud is concentrically disposed about said rotor blades, said shroud in combination with said tip portions defining a clearance gap. At least one circumferential shroud leakage discourager is disposed within the shroud. The leakage discourager(s) increase the flow resistance and thus reduce the flow of hot gas flow leakage for a given pressure differential across the clearance gap to improve overall turbine efficiency.

  14. Measuring the rate of local evaporation from the liquid surface under the action of gas flow

    NASA Astrophysics Data System (ADS)

    Lyulin, Yu. V.; Feoktistov, D. V.; Afanas'ev, I. A.; Chachilo, E. S.; Kabov, O. A.; Kuznetsov, G. V.

    2015-07-01

    The dynamics of evaporation from the surface of a liquid layer under the action of a gas flow has been studied. Correlation dependences of the rate of liquid evaporation on the gas flow rate and temperature for the ethanol-air system have been obtained and compared to other published experimental data. It is established that, for the two-phase systems studied, the evaporation rate growth with increasing temperature exhibits an almost identical character independently of the thermal properties of particular liquids and gases. In contrast, the character of the evaporation rate growth with increasing gas flow velocity significantly depends on these properties.

  15. Mechanism of Action of Melaleuca alternifolia (Tea Tree) Oil on Staphylococcus aureus Determined by Time-Kill, Lysis, Leakage, and Salt Tolerance Assays and Electron Microscopy

    PubMed Central

    Carson, Christine F.; Mee, Brian J.; Riley, Thomas V.

    2002-01-01

    The essential oil of Melaleuca alternifolia (tea tree) has broad-spectrum antimicrobial activity. The mechanisms of action of tea tree oil and three of its components, 1,8-cineole, terpinen-4-ol, and α-terpineol, against Staphylococcus aureus ATCC 9144 were investigated. Treatment with these agents at their MICs and two times their MICs, particularly treatment with terpinen-4-ol and α-terpineol, reduced the viability of S. aureus. None of the agents caused lysis, as determined by measurement of the optical density at 620 nm, although cells became disproportionately sensitive to subsequent autolysis. Loss of 260-nm-absorbing material occurred after treatment with concentrations equivalent to the MIC, particularly after treatment with 1,8-cineole and α-terpineol. S. aureus organisms treated with tea tree oil or its components at the MIC or two times the MIC showed a significant loss of tolerance to NaCl. When the agents were tested at one-half the MIC, only 1,8-cineole significantly reduced the tolerance of S. aureus to NaCl. Electron microscopy of terpinen-4-ol-treated cells showed the formation of mesosomes and the loss of cytoplasmic contents. The predisposition to lysis, the loss of 260-nm-absorbing material, the loss of tolerance to NaCl, and the altered morphology seen by electron microscopy all suggest that tea tree oil and its components compromise the cytoplasmic membrane. PMID:12019108

  16. Improving Indigenous Completion Rates in Mainstream TAFE: An Action Research Approach

    ERIC Educational Resources Information Center

    Balatti, Jo; Gargano, Lyn; Goldman, Martha; Wood, Gary; Woodlock, Julie

    2004-01-01

    Indigenous engagement with vocational education and training (VET) has improved significantly, but successful Indigenous completion rates are lower nationally when compared to the overall population. This report, based on an action research project, examines intra-institutional factors at four Queensland TAFE (technical and further education)…

  17. 49 CFR 385.17 - Change to safety rating based upon corrective actions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 5 2013-10-01 2013-10-01 false Change to safety rating based upon corrective actions. 385.17 Section 385.17 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION FEDERAL MOTOR CARRIER SAFETY REGULATIONS SAFETY FITNESS PROCEDURES General...

  18. Leakage Suppression in the Toric Code

    NASA Astrophysics Data System (ADS)

    Suchara, Martin; Cross, Andrew; Gambetta, Jay

    2015-03-01

    Quantum codes excel at correcting local noise but fail to correct leakage faults that excite qubits to states outside the computational space. Aliferis and Terhal have shown that an accuracy threshold exists for leakage faults using gadgets called leakage reduction units (LRUs). However, these gadgets reduce the threshold and increase experimental complexity, and the costs have not been thoroughly understood. We explore a variety of techniques for leakage resilience in topological codes. Our contributions are threefold. First, we develop a leakage model that differs in critical details from earlier models. Second, we use Monte-Carlo simulations to survey several syndrome extraction circuits. Third, given the capability to perform 3-outcome measurements, we present a dramatically improved syndrome processing algorithm. Our simulations show that simple circuits with one extra CNOT per qubit reduce the accuracy threshold by less than a factor of 4 when leakage and depolarizing noise rates are comparable. This becomes a factor of 2 when the decoder uses 3-outcome measurements. Finally, when the physical error rate is less than 2 ×10-4 , placing LRUs after every gate may achieve the lowest logical error rate. We expect that the ideas may generalize to other topological codes.

  19. Building trust: Heart rate synchrony and arousal during joint action increased by public goods game.

    PubMed

    Mitkidis, Panagiotis; McGraw, John J; Roepstorff, Andreas; Wallot, Sebastian

    2015-10-01

    The physiological processes underlying trust are subject of intense interest in the behavioral sciences. However, very little is known about how trust modulates the affective link between individuals. We show here that trust has an effect on heart rate arousal and synchrony, a result consistent with research on joint action and experimental economics. We engaged participants in a series of joint action tasks which, for one group of participants, was interleaved with a PGG, and measured their heart synchrony and arousal. We found that the introduction of the economic game shifted participants' attention to the dynamics of the interaction. This was followed by increased arousal and synchrony of heart rate profiles. Also, the degree of heart rate synchrony was predictive of participants' expectations regarding their partners in the economic game. We conclude that the above changes in physiology and behavior are shaped by the valuation of other people's social behavior, and ultimately indicate trust building process. PMID:26037635

  20. Changes in search rate but not in the dynamics of exogenous attention in action videogame players.

    PubMed

    Hubert-Wallander, Bjorn; Green, C Shawn; Sugarman, Michael; Bavelier, Daphne

    2011-11-01

    Many previous studies have shown that the speed of processing in attentionally demanding tasks seems enhanced following habitual action videogame play. However, using one of the diagnostic tasks for efficiency of attentional processing, a visual search task, Castel and collaborators (Castel, Pratt, & Drummond, Acta Psychologica 119:217-230, 2005) reported no difference in visual search rates, instead proposing that action gaming may change response execution time rather than the efficiency of visual selective attention per se. Here we used two hard visual search tasks, one measuring reaction time and the other accuracy, to test whether visual search rate may be changed by action videogame play. We found greater search rates in the gamer group than in the nongamer controls, consistent with increased efficiency in visual selective attention. We then asked how general the change in attentional throughput noted so far in gamers might be by testing whether exogenous attentional cues would lead to a disproportional enhancement in throughput in gamers as compared to nongamers. Interestingly, exogenous cues were found to enhance throughput equivalently between gamers and nongamers, suggesting that not all mechanisms known to enhance throughput are similarly enhanced in action videogamers. PMID:21901575

  1. Zero leakage sealings

    NASA Astrophysics Data System (ADS)

    Kotesovec, Bernhard; Steinrück, Herbert

    2010-11-01

    The piston rod of a reciprocating compressor is sealed with elastic cylindrical sealing elements. Across the sealings the pressure drops from the operating pressure to the ambient pressure. The lubrication gap between the elastic sealing and reciprocating piston rod is studied with the aim to find conditions of a leakage free sealing. The flow in the lubrication gap and the elastic deformation of the sealing are determined simultaneously. The net-flow during one cycle of the reciprocating piston rod is calculated. It turns out that maintaining zero leakage is very sensible. Indeed the outbound flow during out-stroke has to be equal the inbound flow during the in-stroke. By prescribing a special shape of the undeformed sealing zero leakage can be attained - at least theoretically for certain operating conditions. It turns out that temperature dependent material data and a model for cavitation is necessary. The model, its numerical implementation and results will be discussed.

  2. Heart rate variability effect on the myocyte action potential duration restitution: insights from switched systems theory.

    PubMed

    Dvir, Hila; Zlochiver, Sharon

    2011-01-01

    The physiological heart rate presents a stochastic behavior known as heart rate variability (HRV). In this framework the influence of HRV on the action potential duration (APD) of the atrial myocyte is analyzed in a computer model. We have found that introducing HRV into the myocyte action potential model decreases the APD of the extra beat S2 in an S1-S2 protocol compared to constant heart rate. A possible theoretical explanation for this is also presented and is derived from switched systems theory. It is suggested to consider the myocyte action potential phase 4 and phase 2 as two operation modes of a switching system and analyze the stability of switching between them. Since random switching is known to have a stabilization effect on a switching system, this might explain why HRV has a stabilization effect on the myocyte APD restitution. Implications of this finding include reduced system stability for conditions with low HRV. A possible application for this phenomenon regards artificial pacemakers, where a preset added HRV is predicted to reduce susceptibility to arrhythmias. PMID:22254402

  3. 40 CFR 89.316 - Analyzer leakage and response time.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Equipment Provisions § 89.316 Analyzer leakage and response time. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for...

  4. 40 CFR 89.316 - Analyzer leakage and response time.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Equipment Provisions § 89.316 Analyzer leakage and response time. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for...

  5. 40 CFR 90.324 - Analyzer leakage check.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Provisions § 90.324 Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for the portion of the system being...

  6. 40 CFR 89.316 - Analyzer leakage and response time.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Equipment Provisions § 89.316 Analyzer leakage and response time. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for...

  7. 40 CFR 90.324 - Analyzer leakage check.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Provisions § 90.324 Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for the portion of the system being...

  8. 40 CFR 90.324 - Analyzer leakage check.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Provisions § 90.324 Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for the portion of the system being...

  9. 40 CFR 90.324 - Analyzer leakage check.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Provisions § 90.324 Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for the portion of the system being...

  10. 40 CFR 89.316 - Analyzer leakage and response time.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Equipment Provisions § 89.316 Analyzer leakage and response time. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for...

  11. 40 CFR 90.324 - Analyzer leakage check.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Provisions § 90.324 Analyzer leakage check. (a) Vacuum side leak check. (1) Check any location within the analysis system where a vacuum leak could affect the test results. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for the portion of the system being...

  12. 40 CFR 89.316 - Analyzer leakage and response time.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Equipment Provisions § 89.316 Analyzer leakage and response time. (a) Vacuum side leak check. (1) Any location within the analysis system where a vacuum leak could affect the test results must be checked. (2) The maximum allowable leakage rate on the vacuum side is 0.5 percent of the in-use flow rate for...

  13. Determination of leakage areas in nuclear piping

    SciTech Connect

    Keim, E.

    1997-04-01

    For the design and operation of nuclear power plants the Leak-Before-Break (LBB) behavior of a piping component has to be shown. This means that the length of a crack resulting in a leak is smaller than the critical crack length and that the leak is safely detectable by a suitable monitoring system. The LBB-concept of Siemens/KWU is based on computer codes for the evaluation of critical crack lengths, crack openings, leakage areas and leakage rates, developed by Siemens/KWU. In the experience with the leak rate program is described while this paper deals with the computation of crack openings and leakage areas of longitudinal and circumferential cracks by means of fracture mechanics. The leakage areas are determined by the integration of the crack openings along the crack front, considering plasticity and geometrical effects. They are evaluated with respect to minimum values for the design of leak detection systems, and maximum values for controlling jet and reaction forces. By means of fracture mechanics LBB for subcritical cracks has to be shown and the calculation of leakage areas is the basis for quantitatively determining the discharge rate of leaking subcritical through-wall cracks. The analytical approach and its validation will be presented for two examples of complex structures. The first one is a pipe branch containing a circumferential crack and the second one is a pipe bend with a longitudinal crack.

  14. Sodium sulfate impacts feeding, specific dynamic action, and growth rate in the freshwater bivalve Corbicula fluminea.

    PubMed

    Soucek, David John

    2007-08-01

    Sodium sulfate is a ubiquitous salt that reaches toxic concentrations due to mining and other industrial activities, yet is currently unregulated at the Federal level in the United States. Previous studies have documented reduced growth of clams downstream of sulfate-dominated effluents, altered bioenergetics in filter-feeding invertebrates, and interactions between sulfate and other toxicants. Therefore, the purpose of this study was to determine if sodium sulfate affects the bioenergetics of the filter-feeding, freshwater bivalve, Corbicula fluminea, and the mechanism by which the effects are elicited. In addition to measuring effects on feeding, respiration and growth rates, I evaluated the relative sensitivity of a green algae consumed by clams to determine if top-down or bottom-up effects might be exhibited under field conditions. This study demonstrated that sodium sulfate had no effect on basal metabolic rates, but significantly reduced the feeding, post-feeding metabolic, and growth rates of C. fluminea. The proposed mechanism for these impacts is that filtering rates are reduced upon exposure, resulting in reduced food consumption and therefore, preventing increased metabolic rates normally associated with post-feeding specific dynamic action (SDA). In the field, these effects may cause changes in whole stream respiration rates and organic matter dynamics, as well as alter uptake rates of other food-associated contaminants like selenium, the toxicity of which is known to be antagonized by sulfate, in filter-feeding bivalves. PMID:17590452

  15. Residential Forced Air System Cabinet Leakage and Blower Performance

    SciTech Connect

    Walker, Iain S.; Dickerhoff, Darryl J.; Delp, William W.

    2010-03-01

    This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit ? indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called"ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment". The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823"Performance Standard for air handlers in residential space conditioning systems".

  16. Geologic Carbon Sequestration: Leakage Potential and Policy Implications

    NASA Astrophysics Data System (ADS)

    Bielicki, J. M.; Peters, C. A.; Fitts, J. P.; Wilson, E. J.

    2014-12-01

    The geologic reservoirs that could be used for long-term sequestration of carbon dioxide (CO2) may have natural or manmade pathways that allow injected CO2, or the brine it displaces, to leak into overlying formations. Using a basin-scale leakage estimation model, we investigated the geophysical parameters that govern this leakage, and the resulting accumulations of leaked fluids in overlying formations. The results are discussed in the context of two polices aimed at governing long-term sequestration and protecting groundwater: the U.S. DOE guideline for storage permanence and the U.S. EPA UIC Program Class VI Rule. For a case study of CO2 injection into the Mt. Simon sandstone in the Michigan sedimentary basin, we showed that (1) the U.S. DOE guideline would allow for more leakage from larger injection projects than for smaller ones; (2) leakage amounts are determined mostly by well leakage permeability rather than by variation in formation permeabilities; (3) numerous leaking wells with anomalously high leakage permeabilities are necessary in order to achieve substantial leakage rates; (4) leakage can reach potable groundwater but intervening stratigraphic traps reduce the amount to be multiple orders of magnitude less than the leakage out of the reservoir, and (5) this leakage can reduce the Area of Review that is defined by the U.S. EPA as the area within which leakage can threaten groundwater. In summary, leakage that exceeds the U.S. DOE storage permanence goal would occur only under extreme conditions, the amount that reaches shallow potable groundwater may be inconsequential from a pollution standpoint, and leakage may be beneficial. Future federal policies should be harmonized to achieve the dual goals of protecting groundwater while allowing for adaptive management that incorporates uncertainties and imperfections inherent in geologic reservoirs.

  17. Air leakage in residential solar heating systems

    NASA Astrophysics Data System (ADS)

    Shingleton, J. G.; Cassel, D. E.; Overton, R. L.

    1981-02-01

    A series of computer simulations was performed to evaluate the effects of component air leakage on system thermal performance for a typical residential solar heating system, located in Madison, Wisconsin. Auxiliary energy required to supplement solar energy for space heating was determined using the TRNSYS computer program, for a range of air leakage rates at the solar collector and pebble bed storage unit. The effects of heat transfer and mass transfer between the solar equipment room and the heated building were investigated. The effect of reduced air infiltration into the building due to pressurized by the solar air heating system were determined. A simple method of estimating the effect of collector array air leakage on system thermal performance was evaluated, using the f CHART method.

  18. Electrical leakage detection circuit

    DOEpatents

    Wild, Arthur

    2006-09-05

    A method is provided for detecting electrical leakage between a power supply and a frame of a vehicle or machine. The disclosed method includes coupling a first capacitor between a frame and a first terminal of a power supply for a predetermined period of time. The current flowing between the frame and the first capacitor is limited to a predetermined current limit. It is determined whether the voltage across the first capacitor exceeds a threshold voltage. A first output signal is provided when the voltage across the capacitor exceeds the threshold voltage.

  19. Evaluation of Impacts of Permeability and Porosity of Storage Formations on Leakage Risk of Deep Groundwater and Carbon Dioxide Due to Geologic Carbon Dioxide Storage

    NASA Astrophysics Data System (ADS)

    Lee, S.; Park, J. Y.; Park, S. U.; Kim, J. M.; Kihm, J. H.

    2014-12-01

    proportional to them. In addition, the leakage rate and amount of CO2 are more sensitive to permeability than porosity of the storage formation. This work was supported by the Geo-Advanced Innovative Action (GAIA) Program funded by the Korea Environmental Industry and Technology Institute (KEITI), Ministry of Environment, Republic of Korea.

  20. Endoscopic Treatment of Stump Leakage Related to the Ileal Conduit

    PubMed Central

    Odemis, Bulent; Oztas, Erkin; Akpinar, Muhammet Yener; Olcucuoglu, Erkan; Kayacetin, Ertugrul

    2016-01-01

    Abstract Background: Ileal conduit with leakage from either the anastomotic site or the stump is associated with high morbidity and mortality rates. The standard treatment of stump leakage is surgery. Case Presentation: A 60-year-old male patient was admitted to our hospital with complaint of hematuria and bladder carcinoma was diagnosed. After performing radical cystectomy and ileal conduit, he developed fever with abdominal pain within the first week of surgery. Stump leakage was diagnosed by endoscopic examination performed through a gastroscope. After two over-the-scope clips (OTSCs) were applied to the stump, vinyl mesh was inserted into the space between the OTSCs. Later, cyanoacrylat and lipiodol were repelled on the OTSCs and vinyl mesh. Subsequently, stump leakage was resolved. Conclusion: This is the first case of stump leakage related to ileal conduit that has been treated endoscopically, according to the current literature. PMID:27579432

  1. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-01-01

    Duct leakage often needs to be measured to demonstrate compliance with requirements or to determine energy or Indoor Air Quality (IAQ) impacts. Testing is often done using standards such as ASTM E1554 (ASTM 2013) or California Title 24 (California Energy Commission 2013 & 2013b), but there are several choices of methods available within the accepted standards. Determining which method to use or not use requires an evaluation of those methods in the context of the particular needs. Three factors that are important considerations are the cost of the measurement, the accuracy of the measurement and the repeatability of the measurement. The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards.

  2. Duct Leakage Repeatability Testing

    SciTech Connect

    Walker, Iain; Sherman, Max

    2014-08-01

    The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

  3. Multifamily Envelope Leakage Model

    SciTech Connect

    Faakye, Omari; Griffiths, Dianne

    2015-05-08

    “The cost for blower testing is high, because it is labor intensive, and it may disrupt occupants in multiple units. This high cost and disruption deter program participants, and dissuade them from pursuing energy improvements that would trigger air leakage testing, such as improvements to the building envelope.” This statement found in a 2012 report by Heschong Mahone Group for several California interests emphasizes the importance of reducing the cost and complexity of blower testing in multifamily buildings. Energy efficiency opportunities are being bypassed. The cost of single blower testing is on the order of $300. The cost for guarded blower door testing—the more appropriate test for assessing energy savings opportunities—could easily be six times that, and that’s only if you have the equipment and simultaneous access to multiple apartments. Thus, the proper test is simply not performed. This research seeks to provide an algorithm for predicting the guarded blower door test result based upon a single, total blower door test.

  4. System-Level Analysis Modeling of Impacts of Operation Schemes of Geologic Carbon Dioxide Storage on Deep Groundwater and Carbon Dioxide Leakage Risk

    NASA Astrophysics Data System (ADS)

    Park, S.; Lee, S.; Park, J.; Kim, J.; Kihm, J.

    2013-12-01

    The objectives of this study are to predict quantitatively groundwater and carbon dioxide flow in deep saline sandstone aquifers under various carbon dioxide injection schemes (injection rate, injection period) and to analyze integratively impacts of such carbon dioxide injection schemes on deep groundwater (brine) and carbon dioxide leakage risk through abandoned wells or faults. In order to achieve the first objective, a series of process-level prediction modeling of groundwater and carbon dioxide flow in a deep saline sandstone aquifer under several carbon dioxide injection schemes was performed using a multiphase thermo-hydrological numerical model TOUGH2 (Pruess et al., 1999). The prediction modeling results show that the extent of carbon dioxide plume is significantly affected by such carbon dioxide injection schemes. In order to achieve the second objective, a series of system-level analysis modeling of deep groundwater and carbon dioxide leakage risk through an abandoned well or a fault under several carbon dioxide injection schemes was then performed using a brine and carbon dioxide leakage risk analysis model CO2-LEAK (Kim, 2012). The analysis modeling results show that the rates and amounts of deep groundwater and carbon dioxide leakage through an abandoned well or a fault increase as the carbon dioxide injection rate increases. However, the rates and amounts of deep groundwater and carbon dioxide leakage through an abandoned well or a fault decrease as the carbon dioxide injection period increases. These system-level analysis modeling results for deep groundwater and carbon dioxide leakage risk can be utilized as baseline data for establishing guidelines to mitigate anticipated environmental adverse effects on shallower groundwater systems (aquifers) when deep groundwater and carbon dioxide leakage occur. This work was supported by the Geo-Advanced Innovative Action (GAIA) Program funded by the Korea Environmental Industry and Technology Institute

  5. Insulin transport across capillaries is rate limiting for insulin action in dogs.

    PubMed Central

    Yang, Y J; Hope, I D; Ader, M; Bergman, R N

    1989-01-01

    This study examined the relationship between transcapillary insulin transport and insulin action in vivo. During euglycemic clamps (n = 7) in normal conscious dogs we simultaneously measured plasma and thoracic duct lymph insulin and glucose utilization (Rd). Clamps consisted of an activation phase with constant insulin infusion (0.6 mU/kg per min) and a deactivation phase. [14C]Inulin was infused as a passively transported control substance. While [14C]inulin reached an equilibrium between plasma and lymph, steady-state (ss) plasma insulin was higher than lymph (P less than 0.05) and the ratio of 3:2 was maintained during basal, activation, and deactivation phases: 18 +/- 2 vs. 12 +/- 1, 51 +/- 2 vs. 32 +/- 1, and 18 +/- 3 vs. 13 +/- 1 microU/ml. In addition, it took longer for lymph insulin to reach ss than plasma insulin during activation and deactivation: 11 +/- 2 vs. 31 +/- 5 and 8 +/- 2 vs. 32 +/- 6 min (P less than 0.02). Rd increased from 2.6 +/- 0.1 to a ss of 6.6 +/- 0.4 mg/kg per min within 50 +/- 8 min. There was a remarkable similarity in the dynamics of insulin in lymph and Rd: the time to reach ss for Rd was not different from lymph insulin (P greater than 0.1), and the relative increases of the two measurements were similar, 164 +/- 45% and 189 +/- 29% (P greater than 0.05). While there was only a modest correlation (r = 0.78, P less than 0.01) between Rd and plasma insulin, the dynamic changes of lymph insulin and Rd showed a strong correlation (r = 0.95, P less than 0.01). The intimate relationship between lymph insulin and Rd suggests that the transcapillary insulin transport is primarily responsible for the delay in Rd. Thus, transcapillary transport may be rate limiting for insulin action, and if altered, it could be an important component of insulin resistance in obesity and diabetes mellitus. PMID:2681272

  6. Neutrino Leakage and Supernova Explosion

    NASA Astrophysics Data System (ADS)

    Liao, Dao-Bing; Zhang, Miao-Jing; Li, Yan; Pan, Jiang-Hong; Chen, Xiu

    2015-04-01

    In the process of supernova explosion the leakage of neutrinos is very important. Adopting an one-dimensional spherically symmetrical model, and under the different neutrino leakage modes, the explosion processes of type II supernovae with masses of 12 M⊙, 14 M⊙, and 15 M⊙ are simulated numerically. The results indicate that all these different neutrino leakage modes have influences on the supernova collapse, shock propagation, and supernova explosion. The best values of the related parameters which are propitious for the type II supernova explosion are given. In addition, the impacts of the equation of state and the compression modulus on the simulated results are discussed.

  7. Photomovement in Dunaliella salina: Fluence rate-response curves and action spectra.

    PubMed

    Wayne, R; Kadota, A; Watanabe, M; Furuya, M

    1991-07-01

    We determined the action spectra of the photophobic responses as well as the phototactic response in Dunaliella salina (Volvocales) using both single cells and populations. The action spectra of the photophobic responses have maxima at 510 nm, the spectrum for phototaxis has a maximum at 450-460 nm. These action spectra are not compatible with the hypothesis that flavoproteins are the photoreceptor pigments, and we suggest that carotenoproteins or rhodopsins act as the photoreceptor pigments. We also conclude that the phototactic response in Dunaliella is an elementary response, quite independent of the step-up and step-down photophobic responses. We also determined the action spectra of the photoaccumulation response in populations of cells adapted to two different salt conditions. Both action spectra have a peak a 490 nm. The photoaccumulation response may be a complex response composed of the phototactic and photophobic responses. Blue or blue-green light does not elicit a photokinetic response in Dunaliella. PMID:24194242

  8. TWO NEW DUCT LEAKAGE TESTS

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  9. Two New Duct Leakage Tests

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    Two variations on the tests for duct leakage currently embodied in ASHRAE Standard 152P (Method of Test for Determining the Design and Seasonal Efficiencies of Residential Thermal Distribution Systems) are presented. Procedures are derived for calculating supply and return duct leakage to/from outside using these new variations. Results of these tests are compared with the original ones in Standard 152P on the basis of data collected in three New York State homes.

  10. Temperature-Induced Leakage from Chilling-Sensitive and Chilling-Resistant Plants 12

    PubMed Central

    Paull, Robert E.

    1981-01-01

    Leakage rates were determined from leaf cells loaded with rubidium and [3H]leucine. There was a differential response between leucine and rubidium leakage depending upon the species used. The rate of leucine leakage shows a small decline below 5 C for two altitudinal variants of Lycopersicon hirsutum Humb. and Bonpl., whereas Lycopersicon esculentum L. showed a marked increase below 5 C. Rubidium showed a marked increase in leakage rate below 10 C with the altitudinal variants, with only a slight increase for the L. esculentum species. A rough relationship existed between rubidium leakage rate at 1 C and the altitude of origin of the L. hirsutum race, the low altitudinal forms having higher leakage rates than the higher altitudinal variants. The L. esculentum lines show a rubidium leakage response similar to that of the high altitude L. hirsutum variants. Higher leakage rates were obtained if the calcium concentration in the medium was less than 1 millimolar and upon addition of metabolic poisons and detergents. The results are consistent with the view that chilling injury causes changes in the membrane and that cell leakage is an early symptom of this change in some species. Some chilling-sensitive species have increased leakage within 1 hour of exposure to chilling temperature. PMID:16661859

  11. Basin-Scale Leakage Risks from Geologic Carbon Sequestration: Impact on Carbon Capture and Storage Energy Market Competitiveness

    SciTech Connect

    Peters, Catherine; Fitts, Jeffrey; Wilson, Elizabeth; Pollak, Melisa; Bielicki, Jeffrey; Bhatt, Vatsal

    2013-03-13

    This three-year project, performed by Princeton University in partnership with the University of Minnesota and Brookhaven National Laboratory, examined geologic carbon sequestration in regard to CO{sub 2} leakage and potential subsurface liabilities. The research resulted in basin-scale analyses of CO{sub 2} and brine leakage in light of uncertainties in the characteristics of leakage processes, and generated frameworks to monetize the risks of leakage interference with competing subsurface resources. The geographic focus was the Michigan sedimentary basin, for which a 3D topographical model was constructed to represent the hydrostratigraphy. Specifically for Ottawa County, a statistical analysis of the hydraulic properties of underlying sedimentary formations was conducted. For plausible scenarios of injection into the Mt. Simon sandstone, leakage rates were estimated and fluxes into shallow drinking-water aquifers were found to be less than natural analogs of CO{sub 2} fluxes. We developed the Leakage Impact Valuation (LIV) model in which we identified stakeholders and estimated costs associated with leakage events. It was found that costs could be incurred even in the absence of legal action or other subsurface interference because there are substantial costs of finding and fixing the leak and from injection interruption. We developed a model framework called RISCS, which can be used to predict monetized risk of interference with subsurface resources by combining basin-scale leakage predictions with the LIV method. The project has also developed a cost calculator called the Economic and Policy Drivers Module (EPDM), which comprehensively calculates the costs of carbon sequestration and leakage, and can be used to examine major drivers for subsurface leakage liabilities in relation to specific injection scenarios and leakage events. Finally, we examined the competiveness of CCS in the energy market. This analysis, though qualitative, shows that financial

  12. Reducing Uncertainty for the DeltaQ Duct Leakage Test

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.; Dickerhoff, Darryl J.

    2004-05-01

    The thermal distribution system couples the HVAC components to the building envelope, and shares many properties of the buildings envelope including moisture, conduction and most especially air leakage performance. Duct leakage has a strong influence on air flow rates through building envelopes (usually resulting in much greater flows than those due to natural infiltration) because unbalanced duct air flows and leaks result in building pressurization and depressurization. As a tool to estimate this effect, the DeltaQ duct leakage test has been developed over the past several years as an improvement to existing duct pressurization tests. It focuses on measuring the air leakage flows to outside at operating conditions that are required for envelope infiltration impacts and energy loss calculations for duct systems. The DeltaQ test builds on the standard envelope tightness blower door measurement techniques by repeating the tests with the system air handler off and on. The DeltaQ test requires several assumptions to be made about duct leakage and its interaction with the duct system and building envelope in order to convert the blower door results into duct leakage at system operating conditions. This study examined improvements to the DeltaQ test that account for some of these assumptions using a duct system and building envelope in a test laboratory. The laboratory measurements used a purpose-built test chamber coupled to a duct system typical of forced air systems in US homes. Special duct leaks with controlled air-flow were designed and installed into an airtight duct system. This test apparatus allowed the systematic variation of the duct and envelope leakage and accurate measurement of the duct leakage flows for comparison to DeltaQ test results. This paper will discuss the laboratory test apparatus design, construction and operation, the various analysis techniques applied to the calculation procedure and present estimates of uncertainty in measured duct

  13. Photomovement in Dunaliella salina: fluence rate-response curves and action spectra.

    PubMed

    Wayne, R; Kadota, A; Watanabe, M; Furuya, M

    1991-01-01

    We determined the action spectra of the photophobic responses as well as the phototactic response in Dunaliella salina (Volvocales) using both single cells and populations. The action spectra of the photophobic responses have maxima at 510 nm, the spectrum for phototaxis has a maximum at 450-460 nm. These action spectra are not compatible with the hypothesis that flavo-proteins are the photoreceptor pigments, and we suggest that carotenoproteins or rhodopsins act as the photoreceptor pigments. We also conclude that the phototactic response in Dunaliella is an elementary response, quite independent of the step-up and step-down photophobic responses. We also determined the action spectra of the photoaccumulation response in populations of cells adapted to two different salt conditions. Both action spectra have a peak at 490 nm. The photoaccumulation response may be a complex response composed of the phototactic and photophobic responses. Blue or blue-green light does not elicit a photokinetic response in Dunaliella. PMID:11538118

  14. Cement Leakage into Adjacent Vertebral Body Following Percutaneous Vertebroplasty

    PubMed Central

    Park, Jae Hoo; Kim, Hyeun Sung

    2016-01-01

    Percutaneous vertebroplasty (PV) is a minimally invasive procedure for osteoporotic vertebral compression fractures that fail to respond to conventional conservative treatment. It significantly improves intolerable back pain within hours, and has a low complication rate. Although rare, PV is not free of complications, most of which are directly related to cement leakage. Because of its association with new adjacent fracture, the importance of cement leakage into the adjacent disc space is paramount. Here, we report an interesting case of cement leakage into the adjacent upper vertebral body as well as disc space following PV. To the best of our knowledge, there has been no report of cement leakage into the adjacent vertebral body following PV. This rare case is presented along with a review of the literature. PMID:27437018

  15. Wall surface leakage effects on MHD power generator performance

    SciTech Connect

    Pian, C.C.P.; Schmitt, E.W.

    1994-12-31

    Internal surface leakage effects on the MHD generator performance were studied using a combined experimental and analytical approach. A method to determine the wall resistances and slag layer conductivities from seed shut-off test data is introduced. These measured resistance values are then utilized in generator performance analyses. Calculated results were compared with measured data from MHD generator tests to verify the modeling approach. Finally, these calculated results were used to investigate the distribution of internal leakage currents as a function of generator size, generator operating conditions, and iron oxide injection rates. An advantage of this analysis methodology is the ability to differentiate between wall leakage and apparent leakage effects in the measured test data.

  16. ANALYSIS OF MEASUREMENT UNCERTAINTIES IN THE NULLING TEST FOR AIR LEAKAGE FROM RESIDENTIAL DUCTS.

    SciTech Connect

    ANDREWS,J.W.

    2001-04-01

    An analysis of measurement uncertainties in a recently proposed method of measuring air leakage in residential duct systems has been carried out. The uncertainties in supply and return leakage rates are expressed in terms of the value of the envelope leakage flow coefficient and the uncertainties in measured pressures and air flow rates. Results of the analysis are compared with data published by two research groups.

  17. The SSME seal test program: Leakage tests for helically-grooved seals

    NASA Technical Reports Server (NTRS)

    Childs, D. W.

    1983-01-01

    Helically grooved annular seal configurations were tested in highly turbulent flow to determine if reduced leakage and enhanced stability would result from the pumping action of the seal. It was found that: (1) leakage of a helically grooved seals decreases with running speed; (2) leakage reduction due to increased running speed is greater at lower values of R sub a; (3) an asymptote for leakage reduction is indicated with increasing running speed; (4) leakage is reduced by reducing the ridge (minimum) and average clearances; (5) leakage increases with increasing pitch angles and with increasing groove depth. Plain seals with smooth rotors and stators will leak more than a helically grooved seal. It was also found that plain seals with a rough rotor and a rough stator leak less than a properly designed helically grooved seal. A properly designed helically grooved seal consumes at least twice as much power as a conventional annular seal.

  18. Experimental and numerical investigations on the leakage flow characteristics of labyrinth seals

    NASA Astrophysics Data System (ADS)

    Li, Jun; Wen, Kesong; Wang, Shizhu; Jiang, Shengke; Kong, Xianglin

    2013-07-01

    Experimental measurements and numerical simulations were conducted to analyze the leakage flow characteristics of the labyrinth seals in this work. Rotating seal test rig was used to measure the leakage flow rate of the labyrinth seals. The detailed leakage flow fields of the labyrinth seals at the experimental measurement conditions were investigated by solving three-dimensional Reynolds-Averaged Navier-Stokes (RANS) equations and k- turbulent model. Effects of the pressure ratio and rotational speed on the leakage flow characteristics of labyrinth seals were studied using the experimental and numerical approaches. The obtained results show that the rotational speed has little influence on the leakage flow rate of the labyrinth seal. The leakage flow rate of the labyrinth seal linearly increase with increasing the pressure ratio at the same sealing clearance and rotational speed. The flow pattern of the labyrinth seal was also illustrated.

  19. THE CARBON DIOXIDE LEAKAGE FROM CHAMBERS MEASURED USING SULFUR HEXAFLUORIDE

    EPA Science Inventory

    In plant chamber studies, if Co2 leaking from a chamber is not quantified, it can lead to an overestimate of assimilation rates and an underestimate of respiration rates: consequently, it is critical that Co2 leakage be determined. Sulfur Hexafluoride (SF6) was introduced into t...

  20. Air-leakage control manual

    SciTech Connect

    Maloney, J.

    1991-05-01

    This manual is for builders and designers who are interested in building energy-efficient homes. The purpose of the manual is to provide the ``how and why`` of controlling air leakage by means of a system called the ``Simple Caulk and Seal`` (SIMPLE{center_dot}CS) system. This manual provides an overview of the purpose and contents of the manual; It discusses the forces that affect air leakage in homes and the benefits of controlling air leakage. Also discussed are two earlier approaches for controlling air leakage and the problems with these approaches. It describes the SIMPLE-{center_dot}CS system. It outlines the standard components of the building envelope that require sealing and provides guidelines for sealing them. It outlines a step-by-step procedure for analyzing and planning the sealing effort. The procedure includes (1) identifying areas to be sealed, (2) determining the most effective and convenient stage of construction in which to do the sealing, and (3) designating the appropriate crew member or trade to be responsible for the sealing.

  1. Air-Leakage Control Manual.

    SciTech Connect

    Maloney, Jim; Washington State Energy Office; United States. Bonneville Power Administration.

    1991-05-01

    This manual is for builders and designers who are interested in building energy-efficient homes. The purpose of the manual is to provide the how and why'' of controlling air leakage by means of a system called the Simple Caulk and Seal'' (SIMPLE{center dot}CS) system. This manual provides an overview of the purpose and contents of the manual; It discusses the forces that affect air leakage in homes and the benefits of controlling air leakage. Also discussed are two earlier approaches for controlling air leakage and the problems with these approaches. It describes the SIMPLE-{center dot}CS system. It outlines the standard components of the building envelope that require sealing and provides guidelines for sealing them. It outlines a step-by-step procedure for analyzing and planning the sealing effort. The procedure includes (1) identifying areas to be sealed, (2) determining the most effective and convenient stage of construction in which to do the sealing, and (3) designating the appropriate crew member or trade to be responsible for the sealing.

  2. Expedient methods of respiratory protection. II. Leakage tests. Final report

    SciTech Connect

    Cooper, D.W.; Hinds, W.C.; Price, J.M.; Weker, R.; Yee, H.S.

    1983-07-01

    The following readily-available materials were tested on a manikin connected to a breathing simulator to determine the fraction of an approximately 2-..mu..m-diameter aerosol that would leak around the seal of the materials to the manikin's face: cotton/polyester shirt material, cotton handkerchief material, toweling (a wash cloth), a surgical mask (Johnson and Johnson Co., model HRI 8137), and a NIOSH-approved disposable face mask (3M, model number 8710). The leakage tests were performed to supplement the measurements of penetration through the materials, conducted as the first phase of this investigation. The leakage tests were performed with the materials held on to the face by three methods, leakage fractions being determined from comparisons with the penetration of the same aerosol for the materials fully taped to the face. At a breathing rate of 37 liters per minute, mean leakages ranged from 0.0 percent to 63 percent. Mean penetrations exclusive of leakage ranged from 0.6 percent to 39 percent. Use of nylon hosiery material (panty hose) to hold the handkerchief material or the disposable face mask to the face was found to be very effective in preventing leakage. Such a combination could be expected to reduce leakage around the handkerchief to about ten percent or less in practice, and around the mask to less than one percent, offering substantial protection from accidentally generated aerosols. The reduction in leakage around the mask provided by the hosiery material suggests the adaptation and use of such an approach in regular industrial hygiene practice. The third and final phase of this investigation is underway, in which the penetration of the materials by particles with diameters between 0.05 and 0.5 ..mu..m is being measured and the effectiveness of the methods for dose reduction in the presence of radioactive aerosols is being modeled.

  3. The vascular actions of insulin control its delivery to muscle and regulate the rate-limiting step in skeletal muscle insulin action

    PubMed Central

    Barrett, EJ; Eggleston, EM; Inyard, AC; Wang, H; Li, G; Chai, W; Liu, Z

    2009-01-01

    Evidence suggests that insulin delivery to skeletal muscle interstitium is the rate-limiting step in insulin-stimulated muscle glucose uptake and that this process is impaired by insulin resistance. In this review we examine the basis for the hypothesis that insulin acts on the vasculature at three discrete steps to enhance its own delivery to muscle: (1) relaxation of resistance vessels to increase total blood flow; (2) relaxation of pre-capillary arterioles to increase the microvascular exchange surface perfused within skeletal muscle (microvascular recruitment); and (3) the trans-endothelial transport (TET) of insulin. Insulin can relax resistance vessels and increase blood flow to skeletal muscle. However, there is controversy as to whether this occurs at physiological concentrations of, and exposure times to, insulin. The microvasculature is recruited more quickly and at lower insulin concentrations than are needed to increase total blood flow, a finding consistent with a physiological role for insulin in muscle insulin delivery. Microvascular recruitment is impaired by obesity, diabetes and nitric oxide synthase inhibitors. Insulin TET is a third potential site for regulating insulin delivery. This is underscored by the consistent finding that steady-state insulin concentrations in plasma are approximately twice those in muscle interstitium. Recent in vivo and in vitro findings suggest that insulin traverses the vascular endothelium via a trans-cellular, receptor-mediated pathway, and emerging data indicate that insulin acts on the endothelium to facilitate its own TET. Thus, muscle insulin delivery, which is rate-limiting for its metabolic action, is itself regulated by insulin at multiple steps. These findings highlight the need to further understand the role of the vascular actions of insulin in metabolic regulation. PMID:19283361

  4. Ratios between acute aquatic toxicity and effects on population growth rates in relation to toxicant mode of action

    SciTech Connect

    Roex, E.W.M.; Gestel, C.A.M. Van; Wezel, A.P. Van; Straalen, N.M. Van

    2000-03-01

    Environmental risk assessment of chemicals is mostly based on the results of standardized toxicity tests. To obtain environmental quality criteria, extrapolation factors are used that depend on the amount and quality of available data. These extrapolation factors do not, however, take into account the mode of action of the compound tested or the life history of the test organism. In this study, the authors analyzed the variability in acute-to-chronic ratios (ACRs) for various chemicals in relation to their mode of action. Chemicals were classified as nonpolar narcotics, polar narcotics, specifically acting compounds, and heavy metals. As an acute endpoint, the LC50 was used; as a chronic endpoint, the lowest test concentration at which the natural rate of population increase (r) is affected, or LOEC(r), was used. Data were derived from the on-line literature. Nonpolar narcotic chemicals demonstrate the smallest variation in ACRs, and acute tests can be used to derive chronic endpoints for this class. For the other classes, the variation in ACRs is larger. Fish species especially show a relatively large ACR. For heavy metals, differences in the mode of action may play an important role in explaining differences in ACRs. For the other three classes, however, it is less reliable to predict chronic toxicity using the results of acute tests. In general, differences in species sensitivity rather than in mode of action for the chemical seem to determine differences in ACRs.

  5. 49 CFR 229.59 - Leakage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Leakage from the main air reservoir and related piping may not exceed an average of 3 pounds per square... shall remain applied at least 5 minutes. (d) Leakage from control air reservoir, related piping,...

  6. 49 CFR 229.59 - Leakage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...) Leakage from the main air reservoir and related piping may not exceed an average of 3 pounds per square... shall remain applied at least 5 minutes. (d) Leakage from control air reservoir, related piping,...

  7. Monetizing Leakage Risk of Geologic CO2 Storage using Wellbore Permeability Frequency Distributions

    NASA Astrophysics Data System (ADS)

    Bielicki, Jeffrey; Fitts, Jeffrey; Peters, Catherine; Wilson, Elizabeth

    2013-04-01

    Carbon dioxide (CO2) may be captured from large point sources (e.g., coal-fired power plants, oil refineries, cement manufacturers) and injected into deep sedimentary basins for storage, or sequestration, from the atmosphere. This technology—CO2 Capture and Storage (CCS)—may be a significant component of the portfolio of technologies deployed to mitigate climate change. But injected CO2, or the brine it displaces, may leak from the storage reservoir through a variety of natural and manmade pathways, including existing wells and wellbores. Such leakage will incur costs to a variety of stakeholders, which may affect the desirability of potential CO2 injection locations as well as the feasibility of the CCS approach writ large. Consequently, analyzing and monetizing leakage risk is necessary to develop CCS as a viable technological option to mitigate climate change. Risk is the product of the probability of an outcome and the impact of that outcome. Assessment of leakage risk from geologic CO2 storage reservoirs requires an analysis of the probabilities and magnitudes of leakage, identification of the outcomes that may result from leakage, and an assessment of the expected economic costs of those outcomes. One critical uncertainty regarding the rate and magnitude of leakage is determined by the leakiness of the well leakage pathway. This leakiness is characterized by a leakage permeability for the pathway, and recent work has sought to determine frequency distributions for the leakage permeabilities of wells and wellbores. We conduct a probabilistic analysis of leakage and monetized leakage risk for CO2 injection locations in the Michigan Sedimentary Basin (USA) using empirically derived frequency distributions for wellbore leakage permeabilities. To conduct this probabilistic risk analysis, we apply the RISCS (Risk Interference of Subsurface CO2 Storage) model (Bielicki et al, 2013a, 2012b) to injection into the Mt. Simon Sandstone. RISCS monetizes leakage risk

  8. "Geyser" leakage on fluorescein angiography.

    PubMed

    Levy, Jaime; Fagan, Xavier J; Lifshitz, Tova; Schneck, Marina

    2013-01-01

    An 82-year-old patient with diabetes was followed up due to moderate nonproliferative diabetic retinopathy with macular edema in the right eye. Visual acuity was 6/36. Focal macular laser was conducted (A). Three years later, the patient presented with blurry vision in the right eye. Visual acuity was 3/60. Vitreous hemorrhage was observed (B), and neovascularization of the disc was suspected (C). Fluorescein angiography (D, mid venous phase; E-F, recirculation phase) confirmed neovascularization of the disc and depicted a striking vertical leakage. Panretinal photocoagulation was started. Possible explanations for the "geyser" leakage may be either a partial posterior vitreous detachment allowing the fluorescein to track upwards but not elsewhere or a pocket of syneretic vitreous allowing the fluorescein passage in which to diffuse, much like the passage the blood would have taken. PMID:24548789

  9. Nondestructive quantification of leakage at the tooth-composite interface and its correlation with material performance parameters.

    PubMed

    Sun, Jirun; Fang, Rui; Lin, Nancy; Eidelman, Naomi; Lin-Gibson, Sheng

    2009-09-01

    Current methods to determine debonding/leakage at the tooth-composite interface are qualitative or semi-quantitative. Our previous work introduced a 3D imaging technique to determine and visualize leakage and its distribution at the interface of cavity wall and composite restoration in model cavities. In this study, an automated program was developed to quantify leakage in terms of area and volume. 3D leakage distribution obtained via the image analysis program was shown to have excellent agreement with leakage visualized by dye penetration. The relationship between leakage and various material performance parameters including processability, shrinkage, stress, and shrinkage strain-rate was determined using a series of experimental composites containing different filler contents. Results indicate that the magnitude of leakage correlated well with polymerization stress, confirming the validity of the common approach utilizing polymerization stress to predict bonding durability. 3D imaging and image analysis provide insight to help understand the relations between leakage and material properties. PMID:19515419

  10. Action Potential Energetics at the Organismal Level Reveal a Trade-Off in Efficiency at High Firing Rates

    PubMed Central

    Gilmour, Kathleen M.; Moorhead, Mayron J.; Perry, Steve F.; Markham, Michael R.

    2014-01-01

    The energetic costs of action potential (AP) production constrain the evolution of neural codes and brain networks. Cellular-level estimates of AP-related costs are typically based on voltage-dependent Na+ currents that drive active transport by the Na+/K+ ATPase to maintain the Na+ and K+ ion concentration gradients necessary for AP production. However, these estimates of AP cost have not been verified at the organismal level. Electric signaling in the weakly electric fish Eigenmannia virescens requires that specialized cells in an electric organ generate APs with large Na+ currents at high rates (200–600 Hz). We measured these currents using a voltage-clamp protocol and then estimated the energetic cost at the cellular level using standard methods. We then used this energy-intensive signaling behavior to measure changes in whole-animal energetics for small changes in electric discharge rate. At low rates, the whole-animal measure of AP cost was similar to our cellular-level estimates. However, AP cost increased nonlinearly with increasing firing rates. We show, with a biophysical model, that this nonlinearity can arise from the increasing cost of maintaining AP amplitude at high rates. Our results confirm that estimates of energetic costs based on Na+ influx are appropriate for low baseline firing rates, but that extrapolating to high firing rates may underestimate true costs in cases in which AP amplitude does not decrease. Moreover, the trade-off between energetic cost and firing rate suggests an additional constraint on the evolution of high-frequency signaling in neuronal systems. PMID:24381281

  11. Method of detecting leakage from geologic formations used to sequester CO.sub.2

    SciTech Connect

    White, Curt; Wells, Arthur; Diehl, J. Rodney; Strazisar, Brian

    2010-04-27

    The invention provides methods for the measurement of carbon dioxide leakage from sequestration reservoirs. Tracer moieties are injected along with carbon dioxide into geological formations. Leakage is monitored by gas chromatographic analyses of absorbents. The invention also provides a process for the early leak detection of possible carbon dioxide leakage from sequestration reservoirs by measuring methane (CH.sub.4), ethane (C.sub.2H.sub.6), propane (C.sub.3H.sub.8), and/or radon (Rn) leakage rates from the reservoirs. The invention further provides a method for branding sequestered carbon dioxide using perfluorcarbon tracers (PFTs) to show ownership.

  12. Semianalytical solution for CO2 leakage through an abandoned well.

    PubMed

    Nordbotten, Jan Martin; Celia, Michael A; Bachu, Stefan; Dahle, Helge K

    2005-01-15

    Capture and subsequent injection of carbon dioxide into deep geological formations is being considered as a means to reduce anthropogenic emissions of CO2 to the atmosphere. If such a strategy is to be successful, the injected CO2 must remain within the injection formation for long periods of time, at least several hundred years. Because mature continental sedimentary basins have a century-long history of oil and gas exploration and production, they are characterized by large numbers of existing oil and gas wells. For example, more than 1 million such wells have been drilled in the state of Texas in the United States. These existing wells represent potential leakage pathways for injected CO2. To analyze leakage potential, modeling tools are needed that predict leakage rates and patterns in systems with injection and potentially leaky wells. A new semianalytical solution framework allows simple and efficient prediction of leakage rates for the case of injection of supercritical CO2 into a brine-saturated deep aquifer. The solution predicts the extent of the injected CO2 plume, provides leakage rates through an abandoned well located at an arbitrary distance from the injection well, and estimates the CO2 plume extent in the overlying aquifer into which the fluid leaks. Comparison to results from a numerical multiphase flow simulator show excellent agreement. Example calculations show the importance of outer boundary conditions, the influence of both density and viscosity contrasts in the resulting solutions, and the potential importance of local upconing around the leaky well. While several important limiting assumptions are required, the new semianalytical solution provides a simple and efficient procedure for estimation of CO2 leakage for problems involving one injection well, one leaky well, and multiple aquifers separated by impermeable aquitards. PMID:15707061

  13. A possible approach for setting a mercury risk-based action level based on tribal fish ingestion rates.

    PubMed

    Harper, Barbara L; Harris, Stuart G

    2008-05-01

    Risks from mercury and other contaminants in fish for a large Columbia River dataset are evaluated in this paper for a range of consumption rates. Extensive ethnohistorical, nutritional, recent ethnographic surveys, and other documentation was reviewed to confirm previous determinations that the traditional subsistence fish consumption rate is 500 pounds per capita annually, or 620 g per day (gpd). Lower comtemporary consumption rates for other population subsets are also discussed. The causes of the current suppression of fish consumption are discussed and the cultural, educational, social, and trade and economic impacts of the loss of fish are considered. Action levels for mercury for riverine Tribes in the Columbia Basin are suggested at 0.1 ppm or less based on the combined risk from mercury plus other contaminants, the higher fish consumption rates, the existing cultural deficit due to loss of salmon and other stressors, the health benefits of fish, and the cultural and economic importance of fish. The goal of fish advisories is to reduce fish consumption even further, which shifts the burden of avoiding risk to the very people who already bear the burdens of contaminant exposure, socio-economic impacts and cultural loss. However, because Tribal communities often do not have the choice of giving up more food, income, religion, culture, and heritage in order to avoid contamination, they are forced into choosing between culture and health. Many tribal members choose to incur chemical risk rather than giving up their culture and religion. We believe that lowering the action level for mercury is part of the federal fiduciary responsibility to American Indian Tribes. PMID:17631290

  14. Effect of mental challenge induced by movie clips on action potential duration in normal human subjects independent of heart rate

    PubMed Central

    Child, Nicholas; Hanson, Ben; Bishop, Martin; Rinaldi, Christopher A; Bostock, Julian; Western, David; Cooklin, Michael; O’Neil, Mark; Wright, Matthew; Razavi, Reza; Gill, Jaswinder; Taggart, Peter

    2014-01-01

    Background Mental stress and emotion have long been associated with ventricular arrhythmias and sudden death in animal models and humans. The effect of mental challenge on ventricular action potential duration (APD) in conscious healthy humans has not been reported. Methods and Results Activation recovery intervals (ARI) measured from unipolar electrograms as a surrogate for APD (n=19) were recorded from right and left ventricular endocardium during steady state pacing while subjects watched an emotionally charged film clip. To assess the possible modulating role of altered respiration on APD, the subjects then repeated the same breathing pattern they had during the stress, but without the movie clip. Haemodynamic parameters (mean, systolic, and diastolic blood pressure, and rate of pressure increase) and respiration rate increased during the stressful part of the film clip (p=0.001). APD decreased during the stressful parts of the film clip, eg for global RV ARI at end of film clip 193.8ms (SD 14) vs 198.0ms (SD13) during the matched breathing control (end film LV 199.8ms (SD16) vs control 201.6ms (SD15), p=0.004. Respiration rate increased during the stressful part of the film clip (by 2 breaths/minute), and was well matched in the respective control period without any haemodynamic or ARI changes. Conclusions Our results document for the first time direct recordings of the effect of a mental challenge protocol on ventricular action potential duration in conscious humans. The effect of mental challenge on APD was not secondary to emotionally-induced altered respiration or heart rate. PMID:24833641

  15. Amniotic Fluid or Its Fatty Acids Produce Actions Similar to Diazepam on Lateral Septal Neurons Firing Rate

    PubMed Central

    Gutiérrez-García, Ana G.; Vásquez-Hernández, Diana Idania

    2013-01-01

    Human amniotic fluid (AF) contains eight fatty acids (FATs), and both produce anxiolytic-like effects in adult rats and appetitive responses in human newborns. The medial amygdala and lateral septal nucleus function are related to social behavior, but the action of AF or its FATs in this circuit is known. We obtained 267 single-unit extracellular recordings in Wistar rats treated with vehicle (1 mL, s.c.; n = 12), human AF (1 mL, s.c.; n = 12), a FAT mixture (1 mL, s.c.; n = 13), diazepam (1 mg/kg, i.p.; n = 11), and fluoxetine (1 mg/kg, p.o.; n = 12). Compared with the vehicle group, the spontaneous septal firing rate in the AF, FAT mixture, and diazepam groups was the lowest and in the fluoxetine group the highest. Cumulative peristimulus histograms indicated that the significant change in septal firing occurred only in the AF and FAT mixture groups and exclusively in those neurons that increased their firing rate during amygdala stimulation. We conclude that human AF and its FATs produce actions comparable to anxiolytic drugs and are able to modify the responsivity of a circuit involved in social behavior, suggesting facilitation of social recognition processes by maternal-fetal fluids. PMID:23864826

  16. Effects of the number of players and game type constraints on heart rate, rating of perceived exertion, and technical actions of small-sided soccer games.

    PubMed

    Abrantes, Catarina I; Nunes, Marta I; Maçãs, Victor M; Leite, Nuno M; Sampaio, Jaime E

    2012-04-01

    The purpose of this study was to identify the variation of heart rate (HR), rating of perceived exertion (RPE), and technical actions between 2 soccer small-sided games (SSGs; 3 × 3 and 4 × 4) in 3 game type constraints (when playing only offense [OFF], playing only defense [DEF], and both situations [GAME]). Sixteen high-level young male players were analyzed (age 15.75 ± 0.45 years; height 172.4 ± 4.83 cm; body mass 64.5 ± 6.44 kg; HRmax199.1 ± 9.08 b·min(-1); and 8.06 ± 1.98 years of soccer practice). All tasks were performed in 4 periods of 4 minutes interspersed with 2 minutes of active recovery. The HR was measured continuously and then analyzed by the time spent into 4 training zones according to individual %HRmax (zone 1 <75%; zone 2 75-84.9%; zone 3 85-89.9%; and zone 4 ≥90%). Results identified that players were most frequently in zones 2 and 3. The 3 × 3 SSGs elicited higher HR and RPE and the most intense situation was GAME. Despite the known higher frequencies from technical actions in SSGs with fewer players, player effectiveness in 3 × 3 and 4 × 4 was identical. The use of GAME, OFF, and DEF game type constraints should be carefully planned. Using the 3 × 3 format seems more adequate when aiming for aerobic performance optimal effects; however, DEF situations should only be used to promote aerobic recovery effects. The inclusion of an additional player in SSGs had different interactions in game type constraints, and only GAME presented adequate intensity. PMID:22446670

  17. Microvascular leakage of plasma proteins after PUVA and UVA

    SciTech Connect

    Staberg, B.; Worm, A.M.; Rossing, N.; Brodthagen, H.

    1982-04-01

    The transcapillary escape rate of albumin (TERalb), is a parameter of the leakage of macromolecules from the total microvasculature. In patients with psoriasis short-term PUVA treatment induces an increase in TERalb. In this study TERalb was measured in 3 groups of normal humans treated with PUVA, UVA and 8-methoxypsoralen. Treatment with PUVA and UVA caused a statistically significant increase in TERalb, whereas treatment with 8-methoxypsoralen did not induce any measurable changes. It is concluded that the UVA irradiation causes the abnormal leakage of macromolecules, whereas psoralen is not the responsible component. Furthermore the phenomenon can be elicited in normals and is not based on a preexisting psoriasis.

  18. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study.

    PubMed

    Berlet, Thomas; Marchon, Mathias

    2016-01-01

    This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema. PMID:27073395

  19. Leakage Characteristics of Dual-Cannula Fenestrated Tracheostomy Tubes during Positive Pressure Ventilation: A Bench Study

    PubMed Central

    2016-01-01

    This study compared the leakage characteristics of different types of dual-cannula fenestrated tracheostomy tubes during positive pressure ventilation. Fenestrated Portex® Blue Line Ultra®, TRACOE® twist, or Rüsch® Traceofix® tracheostomy tubes equipped with nonfenestrated inner cannulas were tested in a tracheostomy-lung simulator. Transfenestration pressures and transfenestration leakage rates were measured during positive pressure ventilation. The impact of different ventilation modes, airway pressures, temperatures, and simulated static lung compliance settings on leakage characteristics was assessed. We observed substantial differences in transfenestration pressures and transfenestration leakage rates. The leakage rates of the best performing tubes were <3.5% of the delivered minute volume. At body temperature, the leakage rates of these tracheostomy tubes were <1%. The tracheal tube design was the main factor that determined the leakage characteristics. Careful tracheostomy tube selection permits the use of fenestrated tracheostomy tubes in patients receiving positive pressure ventilation immediately after stoma formation and minimises the risk of complications caused by transfenestration gas leakage, for example, subcutaneous emphysema. PMID:27073395

  20. Leakage testing of packagings with three-O-ring closure seals

    SciTech Connect

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-10-01

    Both the American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) and the ISO 12807:1996 Safe Transport of Radioactive Materials--Leakage Testing on Packages provide guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements; both also provide guidance for determining appropriate acceptance criteria. Recent radioactive packaging designs have incorporated three-O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results in leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests, in order to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can have two causes: a large leakage in the containment seal or leakage in the inner seal. This paper describes the problem, together with possible solutions and areas that should be addressed in a Safety Analysis Report for Packaging (SARP) before a particular packaging design can be certified for transport. Ultimately, the SARP should provide justification that the requirements for leakage rate testing procedures, including the length of time needed to conduct the tests, will ensure that the containment closure seal is properly tested.

  1. System-Level Numerical Simulation of Geologic Storage of Carbon Dioxide Using a Brine and Carbon Dioxide Leakage Risk Analysis Model

    NASA Astrophysics Data System (ADS)

    Park, S.; Kihm, J.; Kim, J.

    2012-12-01

    A series of system-level numerical simulations of geologic storage of carbon dioxide was performed using a brine and carbon dioxide leakage risk analysis model. This model is composed of three parts as a system. The first part is a process-level simulation of multiphase fluid flow and heat transport in a target storage formation. A multiphase thermo-hydrological numerical model TOUGH2 is implemented for the first part. The second part is a process-level simulation of brine and carbon dioxide leakage toward overlying aquifers and ground surfaces through wells and/or faults. A semi-analytical leakage model ELSA (Princeton Model) is implemented for the second part. The third part is a system-level probabilistic simulation of rates and amounts of brine and carbon dioxide leakage toward overlying aquifers and ground surfaces through wells and/or faults. A Monte Carlo probabilistic model is implemented for the third part. This model is applied to three different cases of hypothetical layered aquifer systems with alternation of sandstone (aquifer) and shale (aquitard). The first aquifer system is horizontal and has 100 abandoned wells. The second aquifer system is horizontal and has 100 abandoned wells and a fault. The third aquifer system is inclined and has 100 abandoned wells. For each case of the aquifer systems, the total simulation time period is set equal to 1,000 years including the carbon dioxide injection period of 50 years. The system-level numerical simulation results show that the carbon dioxide injection results in pore fluid pressure increase and thus causes brine and carbon dioxide leakage through the abandoned wells and/or fault. During the early time period, the pore fluid pressure increases in the target storage formation, and brine begins to leak through the abandoned wells and/or fault. Later, when the carbon dioxide plume reaches the bottom of the abandoned wells and/or fault, carbon dioxide begins to leak, and the brine leakage decreases. In

  2. SSRI enhances sensitivity to background outcomes and modulates response rates: A randomized double blind study of instrumental action and depression.

    PubMed

    Msetfi, Rachel M; Kumar, Poornima; Harmer, Catherine J; Murphy, Robin A

    2016-05-01

    Serotonin reuptake inhibitors (SSRIs) have immediate effects on synaptic levels of serotonin but their therapeutic effects are often delayed. This delay has been suggested to reflect time required for new learning and therefore that SSRIs might be having effects on the learning process. We examined the effects of elevating serotonin levels, through short-term SSRI administration (escitalopram), on learning about perceptions of instrumental control. A randomised double blind procedure was used to allocate healthy people, categorised as mildly depressed (high BDI⩾10: n=76) or not depressed (low BDI⩽5: n=78) to either a drug (escitalopram, 10mg/7days) or placebo control group. Following treatment, participants were trained with a simple task that involved learning the effectiveness of an instrumental action (key press) and the background context at eliciting an outcome (auditory cue) where there was no programmed contingency. The effects of the drug were (i) to moderate response rates and (ii) to enhance sensitivity to the background or context rate of occurrence of the outcome. These findings suggest that serotonin modulates learning about the long-term rate of outcomes, which supports perception of instrumental control, and that this may provide a clue to the mechanism for supporting the development of the therapeutic effects of the drug. PMID:26976091

  3. Zero leakage separable and semipermanent ducting joints

    NASA Technical Reports Server (NTRS)

    Mischel, H. T.

    1973-01-01

    A study program has been conducted to explore new methods of achieving zero leakage, separable and semipermanent, ducting joints for space flight vehicles. The study consisted of a search of literature of existing zero leakage methods, the generation of concepts of new methods of achieving the desired zero leakage criteria and the development of detailed analysis and design of a selected concept. Other techniques of leak detection were explored with a view toward improving this area.

  4. Improving stopping construction to minimize leakage

    PubMed Central

    Grau, Roy H.; Mazzella, Andrew L.; Martikainen, Anu L.

    2015-01-01

    The proper sealing of stoppings is an important step in reducing leakage from the intake to the return airways. Leakage and the subsequent loss of ventilation resulting from improperly sealed stoppings can lead to unhealthy and unsafe working conditions. The research presented in this paper investigates the total leakage of a stopping, including air leakage through the stopping, at the stopping perimeter, and through the coalbed. The study also examines sealing considerations for stoppings that are constructed under roof control screen, the effects that wooden wedges had on inhibiting efficient application of polyurethane foam sealant, and airflow leakage through the surrounding coal. The work involved building a stopping in a dead end room of the NIOSH Safety Research Coal Mine and then pressurising the room using compressed air. Stopping leakage was evaluated by measuring air pressure loss in the enclosed room due to the air leakage. Part of the research utilises a diluted soap solution that was applied to the stopping and the surrounding coal to detect air leakage signified by bubble formations. The results show that stopping leakage can be minimised with proper sealing PMID:26379366

  5. Leakage-current properties of encapsulants

    NASA Technical Reports Server (NTRS)

    Wen, L. C.

    1986-01-01

    A theoretical modeling of leakage current in ethylene vinyl acetate (EVA) and polyvinyl butyral (PVB) modules is being developed and is described. The modeling effort derives mathematical relationships for the bulk and surface conductivites of EVA and PVB, the surface conductivities of glass and polymeric films, and the EVA and PVB pottants, all as functions of environmental parameters. Results from the modeling indicate that for glass/EVA, the glass surface controls the interfacial conductivity, although EVA bulk conductivity controls total leakage current. For PVB/glass, the interface conductivity controls leakage currents for relative humidity (RH) less than 40 to 50%, but PVB bulk conductivity controls leakage current above 50% RH.

  6. Critical Care staffs' attitudes, confidence levels and educational needs correlate with countries' donation rates: data from the Donor Action database.

    PubMed

    Roels, Leo; Spaight, Caroline; Smits, Jacqueline; Cohen, Bernard

    2010-08-01

    To investigate on the impact of Critical Care (CC) staffs' attitudes to donation, their acceptance of the brain death (BD) concept, their confidence with donation-related tasks and educational needs on national donation rates. Donor Action (DA) Hospital Attitude Survey (HAS) data were collected from 19 537 CC staff in 11 countries, including personal attitudes to donation, self-reported knowledge, involvement and comfort levels with donation-related tasks and educational requirements. Countries' donation performance was expressed as Procurement Efficiency Index (PEI) (organs procured and transplanted/deaths from eligible causes). National PEI rates correlated well with CC staffs' average support to donation (R = 0.700, P = 0.014), acceptance of the BD concept (R = 0.742, P = 0.007), confidence levels (R = 0.796, P = 0.002) and average educational requirements with donation-related tasks (R = -0.661, P = 0.025). Nurses reported significantly lower positive attitudes (P < 0.0001), acceptance of the BD concept (P < 0.0001), comfort levels (P < 0.0001) and requested more education (P = 0.0025) than medical staff members. DA's HAS is a powerful, standardized tool to assess CC staffs' attitudes and donation-related skills in different environments. Measures to improve countries' donation performance should focus on guidance and education of CC staff so as to ensure that all practitioners have sufficient knowledge and feel comfortable with donation-related issues. PMID:20210934

  7. [Effects of different growth rates in weaned piglets, starvation and hormonal action, on various metabolic parameters in the blood plasma].

    PubMed

    Dvorák, M

    1979-05-01

    Changes in concentrations of metabolites of the main nutrients in the blood plasma, caused by weaning and by different body weight gains, by starvation, exogenous adrenaline and ASTH administration were studied in 141 weaned piglets of the Large White breed at an age of 26 to 69 days. After weaning, the total protein level showed a faster decrease in the intensively growing piglets than in those with lower growth rates. This rapid decrease was induced by adrenaline. The post-weaning levels of glucose decreased irrespective of the growth rate of the piglets. Adrenaline caused hyperglycaemia and, after 48 hours of starvation, hypoglycaemia. Urea levels significantly increased after weaning. During starvation they remained unchanged, even under exposure to hormonal effects. Cholesterol concentration decreased after weaning, after ACTH and adrenaline administration also showed a decrease. The concentration of non-esterified fatty acids decreased after weaning, the decrease being more pronounced in the piglets with less intensive growth. The action of adrenaline, ACTH, together with an increased level of glucocorticoids, increased the concentration of these acids even in the state of starvation. It is assumed that early piglet weaning implies great metabolic changes which need not impair growth if their character is transient. The author evaluates the suitability of the starter used and parameters chosen for the determination of the metabolic profile of pigs. PMID:223271

  8. An updated computational model of rabbit sinoatrial action potential to investigate the mechanisms of heart rate modulation

    PubMed Central

    Severi, Stefano; Fantini, Matteo; Charawi, Lara A; DiFrancesco, Dario

    2012-01-01

    The cellular basis of cardiac pacemaking is still debated. Reliable computational models of the sinoatrial node (SAN) action potential (AP) may help gain a deeper understanding of the phenomenon. Recently, novel models incorporating detailed Ca2+-handling dynamics have been proposed, but they fail to reproduce a number of experimental data, and more specifically effects of ‘funny’ (If) current modifications. We therefore developed a SAN AP model, based on available experimental data, in an attempt to reproduce physiological and pharmacological heart rate modulation. Cell compartmentalization and intracellular Ca2+-handling mechanisms were formulated as in the Maltsev–Lakatta model, focusing on Ca2+-cycling processes. Membrane current equations were revised on the basis of published experimental data. Modifications of the formulation of currents/pumps/exchangers to simulate If blockers, autonomic modulators and Ca2+-dependent mechanisms (ivabradine, caesium, acetylcholine, isoprenaline, BAPTA) were derived from experimental data. The model generates AP waveforms typical of rabbit SAN cells, whose parameters fall within the experimental ranges: 352 ms cycle length, 80 mV AP amplitude, −58 mV maximum diastolic potential (MDP), 108 ms APD50, and 7.1 V s−1 maximum upstroke velocity. Rate modulation by If-blocking drugs agrees with experimental findings: 20% and 22% caesium-induced (5 mm) and ivabradine-induced (3 μm) rate reductions, respectively, due to changes in diastolic depolarization (DD) slope, with no changes in either MDP or take-off potential (TOP). The model consistently reproduces the effects of autonomic modulation: 20% rate decrease with 10 nm acetylcholine and 28% increase with 1 μm isoprenaline, again entirely due to increase in the DD slope, with no changes in either MDP or TOP. Model testing of BAPTA effects showed slowing of rate, −26%, without cessation of beating. Our up-to-date model describes satisfactorily experimental data

  9. A novel micropump with fixed-geometry valves and low leakage flow

    NASA Astrophysics Data System (ADS)

    Hwang, Il-Han; An, Jae-Yong; Ko, Kwang-Hee; Shin, Sang-Mo; Lee, Jong-Hyun

    2007-08-01

    A novel micropump with fixed-geometry valves was designed and tested with a leakage barrier to reduce leakage flow. Conventional micropumps with fixed-geometry valves have achieved net positive fluid flow from different fluid resistances in diffuser/nozzle channels. However, those micropumps are susceptible to leakage flow even at low pressure differences between the inlet and the outlet because the channels remain normally open state when the pumps are not in operation. Therefore, a leakage barrier in the chamber was designed to reduce leakage flow without interfering with the net positive fluid flow of the diffuser/nozzle channels. The diffuser/nozzle channels, the chamber and the leakage barrier were fabricated on the silicon substrate by KOH etching and the silicon substrate was anodically bonded with a Pyrex glass plate. A PZT disk was bonded on the glass plate by epoxy and was actuated to oscillate the glass diaphragm for flow generation. When the micropump is not operating, the leakage barrier removes most of the gap between the glass plate and the bottom of the chamber. It was experimentally confirmed that the leakage barrier reduced the leakage flow by 96% compared to the case of no leakage barrier at a pressure difference of -400 Pa. Moreover, by applying the holding dc voltage to the PZT disk, a smaller gap can be obtained reducing the leakage flow further down to 0.043 µL min-1 at a holding dc voltage of 100 V. The maximum flow rate was 3.9 µL min-1 at a peak-to-peak driving voltage of 150 V at 20 Hz with a maximum back pressure of around 800 Pa. The approximate device size was 18 × 25 mm2.

  10. 16 CFR 1507.5 - Pyrotechnic leakage.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Pyrotechnic leakage. 1507.5 Section 1507.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.5 Pyrotechnic leakage. The pyrotechnic chamber in fireworks devices shall be...

  11. 16 CFR 1507.5 - Pyrotechnic leakage.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Pyrotechnic leakage. 1507.5 Section 1507.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.5 Pyrotechnic leakage. The pyrotechnic chamber in fireworks devices shall be...

  12. 16 CFR 1507.5 - Pyrotechnic leakage.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Pyrotechnic leakage. 1507.5 Section 1507.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.5 Pyrotechnic leakage. The pyrotechnic chamber in fireworks devices shall be...

  13. 16 CFR 1507.5 - Pyrotechnic leakage.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Pyrotechnic leakage. 1507.5 Section 1507.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.5 Pyrotechnic leakage. The pyrotechnic chamber in fireworks devices shall be...

  14. 16 CFR 1507.5 - Pyrotechnic leakage.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Pyrotechnic leakage. 1507.5 Section 1507.5 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FEDERAL HAZARDOUS SUBSTANCES ACT REGULATIONS FIREWORKS DEVICES § 1507.5 Pyrotechnic leakage. The pyrotechnic chamber in fireworks devices shall be...

  15. 49 CFR 236.735 - Current, leakage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Current, leakage. 236.735 Section 236.735 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Current, leakage. A stray electric current of relatively small value which flows through or across...

  16. 49 CFR 236.735 - Current, leakage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Current, leakage. 236.735 Section 236.735 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Current, leakage. A stray electric current of relatively small value which flows through or across...

  17. 49 CFR 236.735 - Current, leakage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Current, leakage. 236.735 Section 236.735 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Current, leakage. A stray electric current of relatively small value which flows through or across...

  18. 49 CFR 236.735 - Current, leakage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Current, leakage. 236.735 Section 236.735 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Current, leakage. A stray electric current of relatively small value which flows through or across...

  19. 49 CFR 236.735 - Current, leakage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Current, leakage. 236.735 Section 236.735 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Current, leakage. A stray electric current of relatively small value which flows through or across...

  20. Predicting Envelope Leakage in Attached Dwellings

    SciTech Connect

    Faakye, O.; Arena, L.; Griffiths, D.

    2013-07-01

    The most common method for measuring air leakage is to use a single blower door to pressurize and/or depressurize the test unit. In detached housing, the test unit is the entire home and the single blower door measures air leakage to the outside. In attached housing, this 'single unit', 'total', or 'solo' test method measures both the air leakage between adjacent units through common surfaces as well air leakage to the outside. Measuring and minimizing this total leakage is recommended to avoid indoor air quality issues between units, reduce energy losses to the outside, reduce pressure differentials between units, and control stack effect. However, two significant limitations of the total leakage measurement in attached housing are: for retrofit work, if total leakage is assumed to be all to the outside, the energy benefits of air sealing can be significantly over predicted; for new construction, the total leakage values may result in failing to meet an energy-based house tightness program criterion. The scope of this research is to investigate an approach for developing a viable simplified algorithm that can be used by contractors to assess energy efficiency program qualification and/or compliance based upon solo test results.

  1. Bag Test Measures Leakage From Insulated Pipe

    NASA Technical Reports Server (NTRS)

    Schock, Kent D.; Easter, Barry P.

    1994-01-01

    Test quantifies leakage of gas from pipe even though pipe covered with insulation. Involves use of helium analyzer to measure concentration of helium in impermeable bag around pipe. Test administered after standard soap-solution bubble test indicates presence and general class of leakage.

  2. 49 CFR 230.78 - Leakage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Steam Locomotives and Tenders Brake and Signal Equipment § 230.78 Leakage. (a) Main reservoirs and related piping. Leakage from main reservoir and related piping shall be tested at every 92 service day inspection and shall not exceed an...

  3. 49 CFR 230.78 - Leakage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Steam Locomotives and Tenders Brake and Signal Equipment § 230.78 Leakage. (a) Main reservoirs and related piping. Leakage from main reservoir and related piping shall be tested at every 92 service day inspection and shall not exceed an...

  4. A two-dimensional simulation of plasma leakage due to dengue infection

    NASA Astrophysics Data System (ADS)

    Nuraini, N.; Windarto, Jayanti, Swarna; Soewono, Edy

    2014-03-01

    Dengue Hemorrhagic Fever (DHF) is a disease caused by Dengue virus infection. One major characteristic in a patient with DHF is the occurrence of plasma leakage. Plasma leakage is a consequence of the immune system mechanism which activates cytokine. As a result, permeability of vascular will increase. Another characteristic in a DHF patient is hypoalbuminea (decreasing of albumin concentration). Plasma leakage can be modelled by constructing mathematical model of albumin concentration in plasma blood due to increasing of cytokine. In this paper, decreasing of albumin concentration in blood plasma is modelled using diffusion equation. In addition, two-dimensional numerical simulations of albumin concentration are also presented. From the simulation, it is found that the greater leakage rate or the wider leakage area, the greater decreasing albumin concentration will be. Furthermore, when time t increases, the albumin concentration decreases to zero.

  5. Effects of Bulk Microdefects and Metallic Impurities on p-n Junction Leakage Currents in Silicon

    NASA Astrophysics Data System (ADS)

    Kim, Kwang-Salk; Moon, Byeong-sam; Kang, Hee-Bok; Park, Jea-gun; Lee, Bo-Young

    2010-03-01

    The effects of bulk microdefects and metallic impurities on leakage currents at p-n junctions have been evaluated quantitatively by relating leakage currents with bulk defects and metallic impurities, and the results are reported. Bulk defects and metallic impurities, which were introduced by appropriate thermal treatment and intentional contamination by spin-coating metal ion solutions onto the silicon surfaces, were shown to induce heavy leakage currents at p-n junctions, which had been manufactured by boron implantation and phosphorus diffusion. We found the bulk microdefects to be critical in causing leakage currents to flow and propose that their measurements be used as a means for the determination of the bulk defect densities. Die failure rates were also used for the evaluation of the effects of metallic impurities such as Cu, Ni, and Fe on the leakage currents.

  6. Leakage Currents and Gas Generation in Advanced Wet Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2015-01-01

    Currently, military grade, established reliability wet tantalum capacitors are among the most reliable parts used for space applications. This has been achieved over the years by extensive testing and improvements in design and materials. However, a rapid insertion of new types of advanced, high volumetric efficiency capacitors in space systems without proper testing and analysis of degradation mechanisms might increase risks of failures. The specifics of leakage currents in wet electrolytic capacitors is that the conduction process is associated with electrolysis of electrolyte and gas generation resulting in building up of internal gas pressure in the parts. The risk associated with excessive leakage currents and increased pressure is greater for high value advanced wet tantalum capacitors, but it has not been properly evaluated yet. In this work, in Part I, leakages currents in various types of tantalum capacitors have been analyzed in a wide range of voltages, temperatures, and time under bias. Gas generation and the level of internal pressure have been calculated in Part II for different case sizes and different hermeticity leak rates to assess maximal allowable leakage currents. Effects related to electrolyte penetration to the glass seal area have been studied and the possibility of failures analyzed in Part III. Recommendations for screening and qualification to reduce risks of failures have been suggested.

  7. The Gas Leakage Analysis in C/C Composites

    NASA Astrophysics Data System (ADS)

    Nishiyama, Yuichi; Hatta, Hiroshi; Bando, Takamasa; Sugibayashi, Toshio

    Gas leakage through carbon fiber reinforcement carbon composites, C/Cs, was discussed so as to apply C/Cs to heat exchangers in an engine system for a future space-plane. Since C/Cs include many cracks and pores, gas easily leaks through C/Cs. To predict and to prevent the gas flow through a C/C, leakage rate was measured as a function of pressure and gas flow path was identified by micro-observation of the C/C. Then, several analytical models were examined to clarify principal mechanism yielding gas flow resistance. It was found that laminar flow models gave far small flow resistance compared with experimental results, but a model based on adiabatic expansion and compression flow, used for gas leak through labyrinth seals, resulted in reasonable agreement. Finally, Si impregnation in a C/C was examined to minimize the gas leakage. This treatment was shown to be an excellent measure to reduce the gas leakage through C/C.

  8. Preoperative Nutritional Therapy Reduces the Risk of Anastomotic Leakage in Patients with Crohn's Disease Requiring Resections

    PubMed Central

    Guo, Zhen; Guo, Dong; Gong, Jianfeng; Zhu, Weiming; Zuo, Lugen; Sun, Jing; Li, Ning; Li, Jieshou

    2016-01-01

    Background. The rate of anastomotic leakage is high in surgeries for Crohn's disease, and therefore a temporary diverting stoma is often needed. We conducted this study to investigate whether preoperative nutritional therapy could reduce the risk of anastomotic leakage while decreasing the frequency of temporary stoma formation. Methods. This was a retrospective study. Patients requiring bowel resections due to Crohn's disease were reviewed. The rate of anastomotic leakage and temporary diverting stoma was compared between patients who received preoperative nutritional therapy and those on a normal diet before surgery. Possible predictive factors for anastomotic leakage were also analyzed. Results. One hundred and fourteen patients undergoing 123 surgeries were included. Patients in nutritional therapy (NT) group had a significantly lower level of C-reactive protein on the day before surgery. Patients in NT group suffered less anastomotic leakage (2.3% versus 17.9%, P = 0.023) and less temporary diverting stoma (22.8% versus 40.9%, P = 0.036). Serum albumin of the day before surgery ≤35 g/L and preoperative nutritional therapy were identified as factors which independently affected the rate of anastomotic leakage. Conclusion. Preoperative nutritional therapy reduced the risk of anastomotic leakage and the frequency of temporary diverting stoma formation in patients with Crohn's disease requiring resections. PMID:26858749

  9. Differential action for ethanol on baroreceptor reflex control of heart rate and sympathetic efferent discharge in rats

    SciTech Connect

    Xin, Z.; Abdel-Rahman, A.R.A.; Wooles, W.R.

    1988-01-01

    The acute effects of ethanol (0.33, 0.66, or 1 g/kg) on baroreflex control of heart rate (HR) and sympathetic efferent discharge (SED) were investigated in rats. The two higher doses of ethanol caused a progressive and significant increase in baseline SED and a slight increase in HR. The findings suggest that the sensitivity of the reflex control of SED was preserved whereas that of HR was impaired after acute ethanol administration. Since these findings were obtained in the same animals, the data suggest that acute ethanol has a differential action on reflex control of SED and HR. Further, the significant increase in SED after moderate and high doses of ethanol suggests an increased central sympathetic tone as recordings were made from preganglionic nerve fibers (splanchnic nerve). The absence of an increase in baseline MAP, in spite of a significant increase in baseline SED following acute ethanol injection, could be explained, at least in part, by an ethanol-evoked reduction in pressor responsiveness to phenylephrine, an ..cap alpha..-adrenergic agonist.

  10. Review on water leakage control in distribution networks and the associated environmental benefits.

    PubMed

    Xu, Qiang; Liu, Ruiping; Chen, Qiuwen; Li, Ruonan

    2014-05-01

    Water supply is the primary element of an urban system. Due to rapid urbanization and water scarcity, maintaining a stable and safe water supply has become a challenge to many cities, whereas a large amount of water is lost from the pipes of distribution systems. Water leakage is not only a waste of water resources, but also incurs great socio-economic costs. This article presents a comprehensive review on the potential water leakage control approaches and specifically discusses the benefits of each to environmental conservation. It is concluded that water leakage could be further reduced by improving leakage detection capability through a combination of predictive modeling and monitoring instruments, optimizing pipe maintenance strategy, and developing an instant pressure regulation system. The environment could benefit from these actions because of water savings and the reduction of energy consumption as well as greenhouse gas emissions. PMID:25079625

  11. Air leakage of newly instaled residential windows

    SciTech Connect

    Weidt, J.; Weidt, J.

    1980-06-01

    The air-leakage characteristics of five major window designs were measured in a field survey conducted in Twin Cities, Minnesota. A total of 192 windows (16 manufacturers) were tested at 58 sites representing a cross-section of single-family homes, townhouses, low- and high-rise apartments, and condominiums. Air-leakage measurements of the installed windows were compared with the current standard used by industry and government of 0.50 ft/sup 3//min/linear ft of crack. Other parameters studied were: effect of sash and frame material, effect of leakage between window frame and wall, differences among the product lines of a single manufacturer and between manufacturers, effect of installation practices, effect of cold weather on performance, change in performance over time for older windows, and performance of fixed glazing. Based on industry and government standards, 40% of all windows tested showed air-leakage characteristics higher than the 0.50 cfm/lfc standard, and 60% exceeded manufacturers' specifications for performance which in some cases were lower than the general industry standard. Analysis of the impact of various parameters on air-leakage performance showed that the operational design of the window was the most critical determinant although the ranking changes if performance is expressed in cfm/unit area or cfm/opening area. Air leakage was measured using a portable pressurization chamber. Smoke pencils, thermographic techniques and extensive photographic documentation provided additional data as to the location and cause of air leakage problems.

  12. The energy impact of air leakage through insulated walls

    SciTech Connect

    Bhattacharyya, S.; Claridge, D.E.

    1995-08-01

    Infiltration is customarily assumed to increase the heating and cooling load of a building by an amount equal to the mass flow rate of the infiltration times the enthalpy difference between the inside and outside air--with the latent portion of the enthalpy difference sometimes neglected. An experimental and analytical investigation has been conducted on the actual energy impact of air leakage on a well-characterized insulated stud-cavity wall specimen. Calorimetric measurements conducted on the specimen with measured amounts of air leakage introduced under a variety of controlled conditions and configurations verify earlier test cell measurements showing that infiltration heat exchange can lead to a much smaller change in the energy load due to infiltration than is customarily calculated and show the dependence of infiltration heat exchange on flow rate and path length. A analytical model based on fundamental heat and mass transfer principles has been developed and the predicted values of Infiltration Heat Exchange Effectiveness, {var_epsilon}, as a function of air flow rates and effective path length for five study-cavity wall specimen test configurations were consistent with the experimental results. Significant experimental results include: (i) {epsilon} values in the 0.16--0.7 range in the stud-cavity and (ii) {epsilon} values of 0.16 to 0.34 for air exiting the stud-cavity directly across from the entry. These results indicate that significant heat recovery is probable for most leakage occurring through insulated stud cavities.

  13. Self-augmentation of the lengthening of repolarization is related to the shape of the cardiac action potential: implications for reverse rate dependency

    PubMed Central

    Virág, László; Acsai, Károly; Hála, Ottó; Zaza, Antonio; Bitay, Miklós; Bogáts, Gábor; Papp, Julius Gy; Varró, András

    2009-01-01

    Background and purpose: The aims of the present work were to study the mechanism of the reverse rate dependency of different interventions prolonging cardiac action potential duration (APD). Experimental approach: The reverse rate-dependent lengthening effect of APD-prolonging interventions and the possible involvement of IKr (rapid component of the delayed rectifier potassium current) and IK1 (inward rectifier potassium current) were studied by using the standard microelectrode and the whole-cell patch-clamp techniques in dog multicellular ventricular preparations and in myocytes isolated from undiseased human and dog hearts. Key results: All applied drugs – dofetilide (1 µmol·L−1), BaCl2 (10 µmol·L−1), BAY-K-8644 (1 µmol·L−1), veratrine (1 µg·mL−1) – lengthened APD in a reverse rate-dependent manner regardless of their mode of action, suggesting that reverse rate dependency may not represent a specific mechanism of APD prolongation. The E-4031-sensitive current (IKr) and the Ba2+-sensitive current (IK1) were recorded during repolarizing voltage ramps having various steepness and also during action potential waveforms with progressively prolonged APD. Gradually delaying repolarization results in smaller magnitude of IKr and IK1 currents at an isochronal phase of the pulses. This represents a positive feedback mechanism, which appears to contribute to the reverse rate-dependent prolongation of action potentials. Conclusions and implications: Action potential configuration may influence the reverse rate-dependent APD prolongation due to the intrinsic properties of IKr and IK1 currents. Drugs lengthening repolarization by decreasing repolarizing outward, or increasing depolarizing inward, currents are expected to cause reverse rate-dependent APD lengthening with high probability, regardless of which current they modify. PMID:19226285

  14. Urban leakage of liquefied petroleum gas and its impact on Mexico City air quality

    SciTech Connect

    Blake, D.R.; Rowland, F.S.

    1995-08-18

    Alkane hydrocarbons (propane, isobutane, and n-butane) from liquefied petroleum gas (LPG) are present in major quantities throughout Mexico City air because of leakage of the unburned gas from numerous urban sources. These hydrocarbons, together with olefinic minor LPG components, furnish substantial amounts of hydroxyl radical reactivity, a major precursor to formation of the ozone component of urban smog. The combined processes of unburned leakage and incomplete combustion of LPG play significant role in causing the excessive ozone characteristic of Mexico City. Reductions in ozone levels should be possible through changes in LPG composition and lowered rates of leakage. 23 refs., 3 tabs.

  15. Numerical and experimental evaluation of a new low-leakage labyrinth seal

    NASA Technical Reports Server (NTRS)

    Rhode, D. L.; Ko, S. H.; Morrison, G. L.

    1988-01-01

    The effectiveness of a recently developed leakage model for evaluating new design features of most seals is demonstrated. A preliminary assessment of the present stator groove feature shows that it gives approximately a 20 percent leakage reduction with no shaft speed effects. Also, detailed distributions of predicted streamlines, axial velocity, relative pressure and turbulence energy enhance one's physical insight. In addition, the interesting measured effect of axial position of the rotor/stator pair on leakage rate and stator wall axial pressure distribution is examined.

  16. Multigas Leakage Correction in Static Environmental Chambers Using Sulfur Hexafluoride and Raman Spectroscopy.

    PubMed

    Jochum, Tobias; von Fischer, Joseph C; Trumbore, Susan; Popp, Jürgen; Frosch, Torsten

    2015-11-01

    In static environmental chamber experiments, the precision of gas flux measurements can be significantly improved by a thorough gas leakage correction to avoid under- or overestimation of biological activity such as respiration or photosynthesis. Especially in the case of small biological net gas exchange rates or gas accumulation phases during long environmental monitoring experiments, gas leakage fluxes could distort the analysis of the biogenic gas kinetics. Here we propose and demonstrate a general protocol for online correction of diffusion-driven gas leakage in plant chambers by simultaneous quantification of the inert tracer sulfur hexafluoride (SF6) and the investigated biogenic gases using enhanced Raman spectroscopy. By quantifying the leakage rates of carbon dioxide (CO2), methane (CH4), and hydrogen (H2) simultaneously with SF6 in the test chamber, their effective diffusivity ratios of approximately 1.60, 1.96, and 5.65 were determined, each related to SF6. Because our experiments suggest that the effective diffusivity ratios are reproducible for an individual static environmental chamber, even under varying concentration gradients and slight changes of the chamber sealing, an experimental method to quantify gas leakage fluxes by using effective diffusivity ratios and SF6 leakage fluxes is proposed. The method is demonstrated by quantifying the CO2 net exchange rate of a plant-soil ecosystem (Mirabilis jalapa). By knowing the effective chamber diffusivity ratio CO2/SF6 and the measured SF6 leakage rate during the experiment, the leakage contribution to the total CO2 exchange rate could be calculated and the biological net CO2 concentration change within the chamber atmosphere determined. PMID:26492154

  17. Early Alzheimer's Linked to Brain 'Leakage'

    MedlinePlus

    ... https://medlineplus.gov/news/fullstory_159116.html Early Alzheimer's Linked to Brain 'Leakage' Normally, blood-brain barrier ... HealthDay News) -- People in the early stages of Alzheimer's disease may have more "leaks" in the barrier ...

  18. Composite seal reduces alkaline battery leakage

    NASA Technical Reports Server (NTRS)

    Clatterbuck, C. H.; Plitt, K. F.

    1965-01-01

    Composite seal consisting of rubber or plastic washers and a metal washer reduces alkaline battery leakage. Adhesive is applied to each washer interface, and the washers are held together mechanically.

  19. Early Alzheimer's Linked to Brain 'Leakage'

    MedlinePlus

    ... news/fullstory_159116.html Early Alzheimer's Linked to Brain 'Leakage' Normally, blood-brain barrier prevents this from happening To use the ... more "leaks" in the barrier that separates the brain from the bloodstream, a small study suggests. Known ...

  20. Apparatus for detecting leakage of liquid sodium

    DOEpatents

    Himeno, Yoshiaki

    1978-01-01

    An apparatus for detecting the leakage of liquid sodium includes a cable-like sensor adapted to be secured to a wall of piping or other equipment having sodium on the opposite side of the wall, and the sensor includes a core wire electrically connected to the wall through a leak current detector and a power source. An accidental leakage of the liquid sodium causes the corrosion of a metallic layer and an insulative layer of the sensor by products resulted from a reaction of sodium with water or oxygen in the atmospheric air so as to decrease the resistance between the core wire and the wall. Thus, the leakage is detected as an increase in the leaking electrical current. The apparatus is especially adapted for use in detecting the leakage of liquid sodium from sodium-conveying pipes or equipment in a fast breeder reactor.

  1. Leakage test concerns for packagings with three-O-ring closure seals

    SciTech Connect

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-07-01

    Recent radioactive packagings with three-O-ring closure seals, the middle O-ring being the containment seal, have the potential for false positive results from leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests, to reduce both the amount of helium used and the time for the tests. False positive results can be caused by either a large leakage in the containment sea/l or a leakage in the inner seal. This paper describes the problem, together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packaging.

  2. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2007-01-01

    Seal leakage decreases with increasing surface speed due to reduced clearances from disk centrifugal growth. Annular and labyrinth seal leakage are 2-3 times greater than brush and finger seal leakage. Seal leakage rates increase with increasing temperature because of seal clearance growth due to different coefficients of thermal expansion between the seal and test disk. Seal power loss is not strongly affected by inlet temperature. Seal power loss increases with increasing surface speed, seal pressure differential, mass flow rate or flow factor, and radial clearance. The brush and finger seals had nearly the same power loss. Annular and labyrinth seal power loss were higher than finger or brush seal power loss. The brush seal power loss was the lowest and 15-30% lower than annular and labyrinth seal power loss.

  3. Measuring Heat-Exchanger Water Leakage

    NASA Technical Reports Server (NTRS)

    Zampiceni, J.

    1986-01-01

    Water leakage in heat exchanger measured directly with help of electroytic hygrometer. In new technique, flow of nitrogen gas set up in one loop of heat exchanger. Other loop filled with water under pressure. Water concentration produced by leakage of water into nitrogen flow measured by hygrometer. New measurement method determines water concentrations up to 2,000 parts per million with accuracy of +/- 5 percent.

  4. Technology evaluation for space station atmospheric leakage

    SciTech Connect

    Lemon, D.K.; Friesel, M.A.; Griffin, J.W.; Skorpik, J.R.; Shepard, C.L.; Antoniak, Z.I.; Kurtz, R.J.

    1990-02-01

    A concern in operation of a space station is leakage of atmosphere through seal points and through the walls as a result of damage from particle (space debris and micrometeoroid) impacts. This report describes a concept for a monitoring system to detect atmosphere leakage and locate the leak point. The concept is based on analysis and testing of two basic methods selected from an initial technology survey of potential approaches. 18 refs., 58 figs., 5 tabs.

  5. Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings

    SciTech Connect

    Price, P.N.; Shehabi, A.; Chan, R.W.; Gadgil, A.J.

    2006-06-01

    We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematic variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.

  6. Analyzing a database of residential air leakage in the United States

    NASA Astrophysics Data System (ADS)

    Chan, Wanyu R.; Nazaroff, William W.; Price, Phillip N.; Sohn, Michael D.; Gadgil, Ashok J.

    We analyzed more than 70,000 air leakage measurements in houses across the United States to relate leakage area—the effective size of all penetrations of the building shell—to readily available building characteristics such as building size, year built, geographic region, and various construction characteristics. After adjusting for the lack of statistical representativeness of the data, we found that the distribution of leakage area normalized by floor area is approximately lognormal. Based on a classification tree analysis, year built and floor area are the two most significant predictors of leakage area: older and smaller houses tend to have higher normalized leakage areas than newer and larger ones. Multivariate regressions of normalized leakage are presented with respect to these two factors for three house classifications: low-income households, energy program houses, and conventional houses. We demonstrate a method of applying the regression model to housing characteristics from the American Housing Survey to derive a leakage-area distribution for all single-family houses in the US. The air exchange rates implied by these estimates agree reasonably well with published measurements.

  7. Analysis of anastomotic leakage after rectal surgery: A case-control study

    PubMed Central

    Tanaka, Junichiro; Nishikawa, Takeshi; Tanaka, Toshiaki; Kiyomatsu, Tomomichi; Hata, Keisuke; Kawai, Kazushige; Kazama, Shinsuke; Nozawa, Hiroaki; Yamaguchi, Hironori; Ishihara, Soichiro; Sunami, Eiji; Kitayama, Joji; Watanabe, Toshiaki

    2015-01-01

    Background The incidence of anastomotic leakage in rectal surgery is around 10 percent. Poor blood supply to the anastomosis, high anastomotic pressure and tension, increased operative blood loss, long operative time, and male sex are risk factors of anastomotic leakage. In the present study, we examined anastomotic leakage cases in rectal surgery at our institute and tried to ascertain the risk factors. Methods Three hundred fifty-seven consecutive patients who underwent rectal resection with anastomosis between January 2008 and October 2013 were included in the study. Patients were divided into two groups according to the existence of anastomotic leakage. Clinicopathological features, operative procedures, and intraoperative outcomes were compared between the two groups. Regarding intraoperative procedure, we focused on the ligation level of the inferior mesenteric artery, installing a transanal drainage tube in the rectum, and constructing a diverting stoma. Results Anastomotic leakage occurred in eight patients. All of them were male (p = 0.0284). There were no statistical differences in other characteristics of the patients or tumors, in operative procedures, or in intraoperative outcomes. Conclusions In the present study, no statistically significant risk factors for anastomotic leakage in rectal surgery were detected, except for male sex. However, the rate of anastomotic leakage at our institute was revealed to be rather low. Our exertion to preserve good blood flow and to prevent high tension and pressure on the anastomosis in operation may have led to this result. PMID:26042185

  8. Regulatory concerns for leakage testing of packagings with three O-ring closure seals

    SciTech Connect

    Oras, J.J.; Towell, R.H.; Wangler, M.E.

    1997-09-01

    The American National Standard for Radioactive Materials--Leakage Tests on Packages for Shipment (ANSI N14.5) provides guidance for leakage rate testing to show that a particular packaging complies with regulatory requirements and also provides guidance in determining appropriate acceptance criteria. Recent radioactive packagings designs have incorporated three O-ring closure seals, the middle O-ring being the containment seal. These designs have the potential for false positive results of leakage rate tests. The volume between the containment O-ring and the inner O-ring is used for the helium gas required for the leakage rate tests to reduce both the amount of helium used and the time required to conduct the tests. A leak detector samples the evacuated volume between the outer O-ring and the containment O-ring. False positive results can be caused in two ways, a large leakage in the containment seal or leakage in the inner seal. This paper will describe the problem together with possible solutions/areas that need to be addressed in a Safety Analysis Report for Packagings before a particular packaging design can be certified for transport.

  9. Rate and extent of leakage of a magnetic resonance contrast agent tend to be lower under isoflurane anesthesia in comparison to halothane in a rat model of embolic stroke.

    PubMed

    Bezerra, Francisco J; Brown, Morris; Alarcon, William; Karki, Kishor; Knight, Robert A; Keenan, Kelly A; Nagaraja, Tavarekere N

    2014-09-01

    Cerebral blood flow (CBF) and blood-brain barrier (BBB) permeability by arterial spin labeling (ASL)- and dynamic contrast enhanced (DCE)-magnetic resonance imaging (MRI), respectively were repeatedly measured under either halothane (N  =  5) or isoflurane (N  =  5) anesthesia in a rat stroke model of embolic occlusion of middle cerebral artery (MCA). Cerebral blood flow measurements were made after MCA embolization, following intravenous recombinant tissue plasminogen activator (rtPA) treatment at 3 hours post-ictus and again at 48 hours. Blood-brain barrier opening was examined after rtPA infusion and again at 48 hours. Data were analyzed using paired t-tests and significance considered at P < 0·05. The extent and magnitude of CBF reduction due to stroke did not differ between the two groups. Blood-to-brain forward rate constant, K(trans), a measure of BBB permeability, for an MRI contrast agent gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA), was elevated in the ipsilateral hemisphere in both cohorts. However, isoflurane-anesthetized rats exhibited a trend of lower K(trans) values at 48 hours (P  =  0·06) indicating reduced BBB damage in the ipsilateral hemisphere. The area of BBB opening followed a similar trend with the isoflurane-anesthetized group exhibiting a smaller area of BBB damage acutely and at 48 hours compared to the halothane-anesthetized group. PMID:24601723

  10. Total inward leakage of nanoparticles through filtering facepiece respirators.

    PubMed

    Rengasamy, Samy; Eimer, Benjamin C

    2011-04-01

    Nanoparticle (<100 nm size) exposure in workplaces is a major concern because of the potential impact on human health. National Institute for Occupational Safety and Health (NIOSH)-approved particulate respirators are recommended for protection against nanoparticles based on their filtration efficiency at sealed conditions. Concerns have been raised on the lack of information for face seal leakage of nanoparticles, compromising respiratory protection in workplaces. To address this issue, filter penetration and total inward leakage (TIL) through artificial leaks were measured for NIOSH-approved N95 and P100 and European certified Conformit'e Europe'en-marked FFP2 and FFP3 filtering facepiece respirator models sealed to a breathing manikin kept inside a closed chamber. Monodisperse sucrose aerosols (8-80 nm size) generated by electrospray or polydisperse NaCl aerosols (20-1000 nm size) produced by atomization were passed into the chamber. Filter penetration and TIL were measured at 20, 30, and 40 l min(-1) breathing flow rates. The most penetrating particle size (MPPS) was ∼50 nm and filter penetrations for 50 and 100 nm size particles were markedly higher than the penetrations for 8 and 400 nm size particles. Filter penetrations increased with increasing flow rates. With artificially introduced leaks, the TIL values for all size particles increased with increasing leak sizes. With relatively smaller size leaks, the TIL measured for 50 nm size particles was ∼2-fold higher than the values for 8 and 400 nm size particles indicating that the TIL for the most penetrating particles was higher than for smaller and larger size particles. The data indicate that higher concentration of nanoparticles could occur inside the breathing zone of respirators in workplaces where nanoparticles in the MPPS range are present, when leakage is minimal compared to filter penetration. The TIL/penetration ratios obtained for 400 nm size particles were larger than the ratios obtained for

  11. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Distribution systems: Leakage surveys. 192.723... Distribution systems: Leakage surveys. (a) Each operator of a distribution system shall conduct periodic leakage surveys in accordance with this section. (b) The type and scope of the leakage control...

  12. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Distribution systems: Leakage surveys. 192.723... Distribution systems: Leakage surveys. (a) Each operator of a distribution system shall conduct periodic leakage surveys in accordance with this section. (b) The type and scope of the leakage control...

  13. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Distribution systems: Leakage surveys. 192.723... Distribution systems: Leakage surveys. (a) Each operator of a distribution system shall conduct periodic leakage surveys in accordance with this section. (b) The type and scope of the leakage control...

  14. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Distribution systems: Leakage surveys. 192.723... Distribution systems: Leakage surveys. (a) Each operator of a distribution system shall conduct periodic leakage surveys in accordance with this section. (b) The type and scope of the leakage control...

  15. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  16. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  17. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  18. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  19. 21 CFR 870.2640 - Portable leakage current alarm.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Portable leakage current alarm. 870.2640 Section... leakage current alarm. (a) Identification. A portable leakage current alarm is a device used to measure the electrical leakage current between any two points of an electrical system and to sound an alarm...

  20. Detection rate of actionable mutations in diverse cancers using a biopsy-free (blood) circulating tumor cell DNA assay

    PubMed Central

    Schwaederle, Maria; Husain, Hatim; Fanta, Paul T.; Piccioni, David E.; Kesari, Santosh; Schwab, Richard B.; Banks, Kimberly C.; Lanman, Richard B.; Talasaz, AmirAli; Parker, Barbara A.; Kurzrock, Razelle

    2016-01-01

    Analysis of cell-free DNA using next-generation sequencing (NGS) is a powerful tool for the detection/monitoring of alterations present in circulating tumor DNA (ctDNA). Plasma extracted from 171 patients with a variety of cancers was analyzed for ctDNA (54 genes and copy number variants (CNVs) in three genes (EGFR, ERBB2 and MET)). The most represented cancers were lung (23%), breast (23%), and glioblastoma (19%). Ninety-nine patients (58%) had at least one detectable alteration. The most frequent alterations were TP53 (29.8%), followed by EGFR (17.5%), MET (10.5%), PIK3CA (7%), and NOTCH1 (5.8%). In contrast, of 222 healthy volunteers, only one had an aberration (TP53). Ninety patients with non-brain tumors had a discernible aberration (65% of 138 patients; in 70% of non-brain tumor patients with an alteration, the anomaly was potentially actionable). Interestingly, nine of 33 patients (27%) with glioblastoma had an alteration (6/33 (18%) potentially actionable). Overall, sixty-nine patients had potentially actionable alterations (40% of total; 69.7% of patients (69/99) with alterations); 68 patients (40% of total; 69% of patients with alterations), by a Food and Drug Administration (FDA) approved drug. In summary, 65% of diverse cancers (as well as 27% of glioblastomas) had detectable ctDNA aberration(s), with the majority theoretically actionable by an approved agent. PMID:26848768

  1. Using Group Counseling to Improve the Attendance of Elementary School Students with High Rates of Absenteeism: An Action Research Study

    ERIC Educational Resources Information Center

    Webb-Landman, Eleanor

    2012-01-01

    The foundations of academic and social learning are laid in the early years of school, and attendance is critical to school success. However, research suggests that chronic absenteeism is a significant problem at the elementary school level (Chang & Romero, 2008; Romero & Lee, 2007). This paper presents the results of an action research study…

  2. Thermally Induced Leakage from Vibrio marinus, an Obligately Psychrophilic Marine Bacterium1

    PubMed Central

    Haight, Roger D.; Morita, Richard Y.

    1966-01-01

    Haight, Rodger D. (Oregon State University, Corvallis), and Richard Y. Morita. Thermally induced leakage from Vibrio marinus, an obligately psychrophilic bacterium. J. Bacteriol. 92:1388–1393. 1966.—Leakage of various cellular components into the surrounding menstruum occurred when Vibrio marinus was subjected to temperatures above 20 C (organism's maximal growth temperature). These materials, listed in decreasing rates of leakage, were identified as protein, deoxyribonucleic acid, ribonucleic acid, and amino acids. The amount of polar amino acids increased as the time and temperature of heat treatment were increased, whereas the nonpolar amino acids decreased. The ribonucleic acid in the supernatant fluid resulting from heat treatment was both polymeric and nonpolymeric. Leakage of cellular components may be one of the reasons that V. marinus MP-1 loses viability when exposed to temperatures above its maximal temperature for growth. PMID:5924270

  3. Component external leakage and rupture frequency estimates

    SciTech Connect

    Eide, S.A.; Khericha, S.T.; Calley, M.B.; Johnson, D.A.; Marteeny, M.L.

    1991-11-01

    In order to perform detailed internal flooding risk analyses of nuclear power plants, external leakage and rupture frequencies are needed for various types of components - piping, valves, pumps, flanges, and others. However, there appears to be no up-to-date, comprehensive source for such frequency estimates. This report attempts to fill that void. Based on a comprehensive search of Licensee Event Reports (LERs) contained in Nuclear Power Experience (NPE), and estimates of component populations and exposure times, component external leakage and rupture frequencies were generated. The remainder of this report covers the specifies of the NPE search for external leakage and rupture events, analysis of the data, a comparison with frequency estimates from other sources, and a discussion of the results.

  4. Multicenter Analysis of Long-Term Oncologic Impact of Anastomotic Leakage After Laparoscopic Total Mesorectal Excision

    PubMed Central

    Kang, Jeonghyun; Choi, Gyu-Seog; Oh, Jae Hwan; Kim, Nam Kyu; Park, Jun Seok; Kim, Min Jung; Lee, Kang Young; Baik, Seung Hyuk

    2015-01-01

    Abstract This study aims to validate the oncologic outcomes of anastomotic leakage (AL) after laparoscopic total mesorectal excision (TME) in a large multicenter cohort. The impact of AL after laparoscopic TME for rectal cancer surgery has not yet been clearly described. This was a multicenter retrospective study of 1083 patients who underwent laparoscopic TME for nonmetastatic rectal cancer (stage 0–III). AL was defined as an anastomotic complication within 30 days of surgery irrespective of requiring a reoperation or interventional radiology. Estimated local recurrence (LR), disease-free survival (DFS), and overall survival (OS) were compared between the leakage group and the no leakage group using the log-rank method. Multivariate Cox-regression analysis was used to adjust confounding for survival. The incidence of AL was 6.4%. Mortality within 30 days of surgery occurred in 1 patient (1.4%) in the leakage group and 2 patients (0.2%) in the no leakage group. The leakage group showed a higher LR rate (6.4% vs 1.8%, P = 0.011). Five-year DFS and OS were significantly lower in the leakage group than the no leakage group (DFS 71.7% vs 82.1%, P = 0.016, OS 81.8% vs 93.5%, P = 0.007). Multivariate analysis showed that AL was an independent poor prognostic factor for DFS and OS (hazard ratio [HR] = 1.6; 95% confidence intervals [CI]: 1.0–2.6; P = 0.042, HR = 2.1; 95% CI: 1.0–4.2; P = 0.028, respectively). AL after laparoscopic TME was significantly associated with an increased rate of LR, systemic recurrence and poor OS. PMID:26200636

  5. Accounting for geochemical alterations of caprock fracture permeability in basin-scale models of leakage from geologic CO2 reservoirs

    NASA Astrophysics Data System (ADS)

    Guo, B.; Fitts, J. P.; Dobossy, M.; Bielicki, J. M.; Peters, C. A.

    2012-12-01

    Climate mitigation, public acceptance and energy, markets demand that the potential CO2 leakage rates from geologic storage reservoirs are predicted to be low and are known to a high level of certainty. Current approaches to predict CO2 leakage rates assume constant permeability of leakage pathways (e.g., wellbores, faults, fractures). A reactive transport model was developed to account for geochemical alterations that result in permeability evolution of leakage pathways. The one-dimensional reactive transport model was coupled with the basin-scale Estimating Leakage Semi-Analytical (ELSA) model to simulate CO2 and brine leakage through vertical caprock pathways for different CO2 storage reservoir sites and injection scenarios within the Mt. Simon and St. Peter sandstone formations of the Michigan basin. Mineral dissolution in the numerical reactive transport model expands leakage pathways and increases permeability as a result of calcite dissolution by reactions driven by CO2-acidified brine. A geochemical model compared kinetic and equilibrium treatments of calcite dissolution within each grid block for each time step. For a single fracture, we investigated the effect of the reactions on leakage by performing sensitivity analyses of fracture geometry, CO2 concentration, calcite abundance, initial permeability, and pressure gradient. Assuming that calcite dissolution reaches equilibrium at each time step produces unrealistic scenarios of buffering and permeability evolution within fractures. Therefore, the reactive transport model with a kinetic treatment of calcite dissolution was coupled to the ELSA model and used to compare brine and CO2 leakage rates at a variety of potential geologic storage sites within the Michigan basin. The results are used to construct maps based on the susceptibility to geochemically driven increases in leakage rates. These maps should provide useful and easily communicated inputs into decision-making processes for siting geologic CO2

  6. Leakage Sign for Primary Intracerebral Hemorrhage

    PubMed Central

    Hirohata, Masaru; Nakamura, Yukihiko; Takeshige, Nobuyuki; Aoki, Takachika; Hattori, Gousuke; Sakata, Kiyohiko; Abe, Toshi; Uchiyama, Yuusuke; Sakamoto, Teruo; Morioka, Motohiro

    2016-01-01

    Background and Purpose— Recent studies of intracerebral hemorrhage treatments have highlighted the need to identify reliable predictors of hematoma expansion. Several studies have suggested that the spot sign on computed tomographic angiography (CTA) is a sensitive radiological predictor of hematoma expansion in the acute phase. However, the spot sign has low sensitivity for hematoma expansion. In this study, we evaluated the usefulness of a novel predictive method, called the leakage sign. Methods— We performed CTA for 80 consecutive patients presenting with spontaneous intracerebral hemorrhage. Two scans were completed: CTA phase and delayed phase (5 minutes after the CTA phase). By comparing the CTA phase images, we set a region of interest with a 10-mm diameter and calculated the Hounsfield units. We defined a positive leakage sign as a >10% increase in Hounsfield units in the region of interest. Additionally, hematoma expansion was determined on plain computed tomography at 24 hours in patients who did not undergo emergent surgery. Results— Positive spot signs and leakage signs were present in 18 (22%) patients and 35 (43%) patients, respectively. The leakage sign had higher sensitivity (93.3%) and specificity (88.9%) for hematoma expansion than the spot sign. The leakage sign, but not the spot sign, was significantly related with poor outcomes (severely disabled, vegetative state, and death) in all of the patients (P=0.03) and in patients with a hemorrhage in the putamen (P=0.0016). Conclusions— The results indicate that the leakage sign is a useful and sensitive method to predict hematoma expansion. PMID:26931155

  7. The effect of pressure drop on respirator faceseal leakage.

    PubMed

    Janssen, Larry; Weber, Robert

    2005-07-01

    Users of particulate air-purifying respirators are typically told to change their filters when breathing resistance becomes uncomfortable. It has been proposed that a noticeable increase in breathing resistance (pressure drop) may increase airflow through respirator faceseal leaks. This logic has been extended to suggest that respirator user exposure to contaminants may increase because of this theoretical increase in air leakage. Procedures similar to those of previous investigators were used to study this issue. Repeated faceseal leak rate measurements were made at -5.6 through -20.1 mm water pressure drops across the faceseal. Subjects were divided into two groups, representing acceptable fit or unacceptable fit, based on leak rate criteria prescribed by the Occupational Safety and Health Administration (OSHA). Subjects with acceptable fit did not experience an increase in faceseal leak rate with increased pressure drop. Leak rates for subjects with unacceptable fit were highly variable and did not show an association with pressure drop. Results of this study do not support the concept of increased faceseal leakage with increased pressure drop. The evidence does not suggest increased risk of contaminant exposure through the face seal as pressure drop increases. PMID:16020096

  8. Inward leakage in tight-fitting PAPRs.

    PubMed

    Koh, Frank C; Johnson, Arthur T; Rehak, Timothy E

    2011-01-01

    A combination of local flow measurement techniques and fog flow visualization was used to determine the inward leakage for two tight-fitting powered air-purifying respirators (PAPRs), the 3M Breathe-Easy PAPR and the SE 400 breathing demand PAPR. The PAPRs were mounted on a breathing machine head form, and flows were measured from the blower and into the breathing machine. Both respirators leaked a little at the beginning of inhalation, probably through their exhalation valves. In both cases, the leakage was not enough for fog to appear at the mouth of the head form. PMID:21647352

  9. Inward Leakage in Tight-Fitting PAPRs

    PubMed Central

    Koh, Frank C.; Johnson, Arthur T.; Rehak, Timothy E.

    2011-01-01

    A combination of local flow measurement techniques and fog flow visualization was used to determine the inward leakage for two tight-fitting powered air-purifying respirators (PAPRs), the 3M Breathe-Easy PAPR and the SE 400 breathing demand PAPR. The PAPRs were mounted on a breathing machine head form, and flows were measured from the blower and into the breathing machine. Both respirators leaked a little at the beginning of inhalation, probably through their exhalation valves. In both cases, the leakage was not enough for fog to appear at the mouth of the head form. PMID:21647352

  10. A method to investigate inter-aquifer leakage using hydraulics and multiple environmental tracers

    NASA Astrophysics Data System (ADS)

    Priestley, Stacey; Love, Andrew; Wohling, Daniel; Post, Vincent; Shand, Paul; Kipfer, Rolf; Tyroller, Lina

    2016-04-01

    Informed aquifer management decisions regarding sustainable yields or potential exploitation require an understanding of the groundwater system (Alley et al. 2002, Cherry and Parker 2004). Recently, the increase in coal seam gas (CSG) or shale gas production has highlighted the need for a better understanding of inter-aquifer leakage and contaminant migration. In most groundwater systems, the quantity or location of inter-aquifer leakage is unknown. Not taking into account leakage rates in the analysis of large scale flow systems can also lead to significant errors in the estimates of groundwater flow rates in aquifers (Love et al. 1993, Toth 2009). There is an urgent need for robust methods to investigate inter-aquifer leakage at a regional scale. This study builds on previous groundwater flow and inter-aquifer leakage studies to provide a methodology to investigate inter-aquifer leakage in a regional sedimentary basin using hydraulics and a multi-tracer approach. The methodology incorporates geological, hydrogeological and hydrochemical information in the basin to determine the likelihood and location of inter-aquifer leakage. Of particular benefit is the analysis of hydraulic heads and environmental tracers at nested piezometers, or where these are unavailable bore couplets comprising bores above and below the aquitard of interest within a localised geographical area. The proposed methodology has been successful in investigating inter-aquifer leakage in the Arckaringa Basin, South Australia. The suite of environmental tracers and isotopes used to analyse inter-aquifer leakage included the stable isotopes of water, radiocarbon, chloride-36, 87Sr/86Sr and helium isotopes. There is evidence for inter-aquifer leakage in the centre of the basin ~40 km along the regional flow path. This inter-aquifer leakage has been identified by a slight draw-down in the upper aquifer during pumping in the lower aquifer, overlap in Sr isotopes, δ2H, δ18O and chloride

  11. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    SciTech Connect

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Warme und Feuchte instationar Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  12. Moisture Risk in Unvented Attics Due to Air Leakage Paths

    SciTech Connect

    Prahl, D.; Shaffer, M.

    2014-11-01

    IBACOS completed an initial analysis of moisture damage potential in an unvented attic insulated with closed-cell spray polyurethane foam. To complete this analysis, the research team collected field data, used computational fluid dynamics to quantify the airflow rates through individual airflow (crack) paths, simulated hourly flow rates through the leakage paths with CONTAM software, correlated the CONTAM flow rates with indoor humidity ratios from Building Energy Optimization software, and used Wärme und Feuchte instationär Pro two-dimensional modeling to determine the moisture content of the building materials surrounding the cracks. Given the number of simplifying assumptions and numerical models associated with this analysis, the results indicate that localized damage due to high moisture content of the roof sheathing is possible under very low airflow rates. Reducing the number of assumptions and approximations through field studies and laboratory experiments would be valuable to understand the real-world moisture damage potential in unvented attics.

  13. 40 CFR 86.166-12 - Method for calculating emissions due to air conditioning leakage.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determine a refrigerant leakage rate in grams per year from vehicle-based air conditioning units. The... using the following equation: Grams/YRTOT = Grams/YRRP + Grams/YRSP + Grams/YRFH + Grams/YRMC + Grams/YRC Where: Grams/YRTOT = Total air conditioning system emission rate in grams per year and rounded...

  14. Imaging inflammatory plasma leakage in vivo.

    PubMed

    Kenne, E; Lindbom, L

    2011-05-01

    Increased vascular permeability and consequent plasma leakage from postcapillary venules is a cardinal sign of inflammation. Although the movement of plasma constituents from the vasculature to the affected tissue aids in clearing the inflammatory stimulus, excessive plasma extravasation can lead to hospitalisation or death in cases such as influenza-induced pneumonia, burns or brain injury. The use of intravital imaging has significantly contributed to the understanding of the mechanisms controlling the vascular permeability alterations that occur during inflammation. Today, intravital imaging can be performed using optical and non-optical techniques. Optical techniques, which are generally used in experimental settings, include traditional intravital fluorescence microscopy and near-infrared fluorescence imaging. Magnetic resonance (MRI) and radioisotopic imaging are used mainly in the clinical setting, but are increasingly used in experimental work, and can detect plasma leakage without optics. Although these methods are all able to visualise inflammatory plasma leakage in vivo, the spatial and temporal resolution differs between the techniques. In addition, they vary with regards to invasiveness and availability. This overview discusses the use of imaging techniques in the visualisation of inflammatory plasma leakage. PMID:21437352

  15. 49 CFR 230.78 - Leakage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... of 3 psi per minute in a test of 3 minutes duration that is made after the pressure has been reduced to 60 percent of the maximum operating pressure. (b) Brake cylinders. Leakage from brake cylinders... pipe pressure, and with communication to the brake cylinders closed, the brakes on the steam...

  16. 49 CFR 230.78 - Leakage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... of 3 psi per minute in a test of 3 minutes duration that is made after the pressure has been reduced to 60 percent of the maximum operating pressure. (b) Brake cylinders. Leakage from brake cylinders... pipe pressure, and with communication to the brake cylinders closed, the brakes on the steam...

  17. The concept of leakage in threat assessment.

    PubMed

    Meloy, J Reid; O'Toole, Mary Ellen

    2011-01-01

    Leakage in the context of threat assessment is the communication to a third party of an intent to do harm to a target. Third parties are usually other people, but the means of communication vary, and include letters, diaries, journals, blogs, videos on the internet, emails, voice mails, and other social media forms of transmission. Leakage is a type of warning behavior that typically infers a preoccupation with the target, and may signal the research, planning, and implementation of an attack. Nomothetic data suggest that leakage occurs in a majority of cases of attacks on and assassinations of public figures, adult mass murders, adolescent mass murders, and school or campus shootings: very low-frequency, but catastrophic acts of intended and targeted violence. Idiographic or case data illustrate the various permutations of leakage. We discuss the operational importance of the concept, place it in the context of other warning behaviors, emphasize the need for further research, and outline risk management strategies for the mitigation of such acts of violence in both law enforcement and clinical mental health settings. PMID:21710573

  18. Control of Air Leakage in Buildings.

    ERIC Educational Resources Information Center

    Wilson, A. Grant

    This discussion of air leakage emphasizes cause and provides suggestions for elimination of undesirable effects. Cause parameters described are--(1) pressure differential, (2) building shape, (3) temperature differential, (4) opening sizes, (5) mechanical system pressures, and (6) climatic factors. Effects discussed are--(1) increased mechanical…

  19. An Advanced Leakage Scheme for Neutrino Treatment in Astrophysical Simulations

    NASA Astrophysics Data System (ADS)

    Perego, A.; Cabezón, R. M.; Käppeli, R.

    2016-04-01

    We present an Advanced Spectral Leakage (ASL) scheme to model neutrinos in the context of core-collapse supernovae (CCSNe) and compact binary mergers. Based on previous gray leakage schemes, the ASL scheme computes the neutrino cooling rates by interpolating local production and diffusion rates (relevant in optically thin and thick regimes, respectively) separately for discretized values of the neutrino energy. Neutrino trapped components are also modeled, based on equilibrium and timescale arguments. The better accuracy achieved by the spectral treatment allows a more reliable computation of neutrino heating rates in optically thin conditions. The scheme has been calibrated and tested against Boltzmann transport in the context of Newtonian spherically symmetric models of CCSNe. ASL shows a very good qualitative and a partial quantitative agreement for key quantities from collapse to a few hundreds of milliseconds after core bounce. We have proved the adaptability and flexibility of our ASL scheme, coupling it to an axisymmetric Eulerian and to a three-dimensional smoothed particle hydrodynamics code to simulate core collapse. Therefore, the neutrino treatment presented here is ideal for large parameter-space explorations, parametric studies, high-resolution tests, code developments, and long-term modeling of asymmetric configurations, where more detailed neutrino treatments are not available or are currently computationally too expensive.

  20. Pipeline leakage detection using distributed fibre optical temperature sensing

    NASA Astrophysics Data System (ADS)

    Grosswig, S.; Hurtig, E.; Luebbecke, S.; Vogel, B.

    2005-05-01

    The leakage detection system based on the distributed fibre optical temperature measurement method is an analysing method for continuous detection and localization of leakages at pipelines in the steady and unsteady operation states according to the German rules for pipelines TRbF 301/TRFL which is valid in Germany since April 2003. The leakage detection system is useable under the precondition that there is a sufficient large temperature gradient between the leakage area and the unaffected environment. This can be caused by the medium itself or through a physical effect due to the leakage, e.g. gas expansion, evaporation. It's a very sensitive method, so also creeping leakages can be detected.

  1. The Contribution of Ionic Currents to Rate-Dependent Action Potential Duration and Pattern of Reentry in a Mathematical Model of Human Atrial Fibrillation

    PubMed Central

    Lee, Young-Seon; Hwang, Minki; Song, Jun-Seop; Li, Changyong; Joung, Boyoung; Sobie, Eric A.; Pak, Hui-Nam

    2016-01-01

    Persistent atrial fibrillation (PeAF) in humans is characterized by shortening of action potential duration (APD) and attenuation of APD rate-adaptation. However, the quantitative influences of particular ionic current alterations on rate-dependent APD changes, and effects on patterns of reentry in atrial tissue, have not been systematically investigated. Using mathematical models of human atrial cells and tissue and performing parameter sensitivity analysis, we evaluated the quantitative contributions to action potential (AP) shortening and APD rate-adaptation of ionic current remodeling seen with PeAF. Ionic remodeling in PeAF was simulated by reducing L-type Ca2+ channel current (ICaL), increasing inward rectifier K+ current (IK1) and modulating five other ionic currents. Parameter sensitivity analysis, which quantified how each ionic current influenced APD in control and PeAF conditions, identified interesting results, including a negative effect of Na+/Ca2+ exchange on APD only in the PeAF condition. At high pacing rate (2 Hz), electrical remodeling in IK1 alone accounts for the APD reduction of PeAF, but at slow pacing rate (0.5 Hz) both electrical remodeling in ICaL alone (-70%) and IK1 alone (+100%) contribute equally to the APD reduction. Furthermore, AP rate-adaptation was affected by IKur in control and by INaCa in the PeAF condition. In a 2D tissue model, a large reduction (-70%) of ICaL becomes a dominant factor leading to a stable spiral wave in PeAF. Our study provides a quantitative and unifying understanding of the roles of ionic current remodeling in determining rate-dependent APD changes at the cellular level and spatial reentry patterns in tissue. PMID:26964092

  2. Deformation of Fluid Column by Action of Axial Vibration and Some Aspects of High-Rate Thermocapillary Convection

    NASA Technical Reports Server (NTRS)

    Feonychev, Alexander I.; Kalachinskaya, Irina S.; Pokhilko, Victor I.

    1996-01-01

    The deformation of the fluid column by an action of a low-frequency vibration is considered. It is shown that behavior of the free fluid surface depends on the frequency of applied vibration and its amplitude. In the area of very low frequencies when fluid has time to comment on travel of bounding solid walls limiting column, the harmonical oscillations of free surface with given frequency are observed. With increase of vibration frequency the steady-state relief on free fluid surface is formed. If the amplitude of vibration is very small and the frequency corresponding to the first peak in the vibration spectrum on the Mir orbital station, the deformation of free surface tends to zero. Fluid flow induced thermocapillary effect on deformed free surface is more unstable as in the case of smooth cylindrical surface. It was shown that width of heating zone affects very essentially the flow pattern and transition to oscillatory regime of thermocapillary convection.

  3. Structural and leakage integrity of tubes affected by circumferential cracking

    SciTech Connect

    Hernalsteen, P.

    1997-02-01

    In this paper the author deals with the notion that circumferential cracks are generally considered unacceptable. He argues for the need to differentiate two facets of such cracks: the issue of the size and growth rate of a crack; and the issue of the structural strength and leakage potential of the tube in the presence of the crack. In this paper the author tries to show that the second point is not a major concern for such cracks. The paper presents data on the structural strength or burst pressure characteristics of steam generator tubes derived from models and data bases of experimental work. He also presents a leak rate model, and compares the performance of circumferential and axial cracks as far as burst strength and leak rate. The final conclusion is that subject to improvement in NDE capabilities (sizing, detection, growth), that Steam Generator Defect Specific Management can be used to allow circumferentially degraded tubes to remain in service.

  4. A national program for energy-efficient mortgages and home energy rating systems: A blueprint for action. Review draft

    SciTech Connect

    Not Available

    1992-03-01

    This Review Draft reports findings and recommendations of the National Collaborative on Home Energy Rating Systems and Mortgage Incentives for Energy Efficiency. The US Department of Energy, in cooperation with the US Department of Housing and Urban Development, formed this National Collaborative as a National Energy Strategy initiative. Participating in the Collaborative were representatives of the primary and secondary mortgage markets, builder and remodeler organizations, real estate and appraiser associations, the home energy rating system industry, utility associations, consumer and public interest groups, state and local government interest groups, and environmental organizations. The Collaborative`s purpose was to develop a voluntary national program encouraging energy efficiency in homes through mortgage incentives linked to home energy ratings.

  5. A national program for energy-efficient mortgages and home energy rating systems: A blueprint for action

    SciTech Connect

    Not Available

    1992-03-01

    This Review Draft reports findings and recommendations of the National Collaborative on Home Energy Rating Systems and Mortgage Incentives for Energy Efficiency. The US Department of Energy, in cooperation with the US Department of Housing and Urban Development, formed this National Collaborative as a National Energy Strategy initiative. Participating in the Collaborative were representatives of the primary and secondary mortgage markets, builder and remodeler organizations, real estate and appraiser associations, the home energy rating system industry, utility associations, consumer and public interest groups, state and local government interest groups, and environmental organizations. The Collaborative's purpose was to develop a voluntary national program encouraging energy efficiency in homes through mortgage incentives linked to home energy ratings.

  6. Regulating emotions uniquely modifies reaction time, rate of force production, and accuracy of a goal-directed motor action.

    PubMed

    Beatty, Garrett F; Fawver, Bradley; Hancock, Gabriella M; Janelle, Christopher M

    2014-02-01

    We investigated how emotion regulation (ER) strategies influence the execution of a memory guided, ballistic pinch grip. Participants (N=33) employed ER strategies (expressive suppression, emotional expression, and attentional deployment) while viewing emotional stimuli (IAPS images). Upon stimulus offset, participants produced a targeted pinch force aimed at 10% of their maximum voluntary contraction. Performance measures included reaction time (RT), rate of force production, and performance accuracy. As hypothesized, attentional deployment resulted in the slowest RT, largest rate of force production, and poorest performance accuracy. In contrast, expressive suppression reduced the rate of force production and increased performance accuracy relative to emotional expression and attentional deployment. Findings provide evidence that emotion regulation strategies uniquely influence human movement. Future work should further delineate the interacting role that emotion regulation strategies have in modulating both affective experience and motor performance. PMID:24576703

  7. Engine panel seals for hypersonic engine applications: High temperature leakage assessments and flow modelling

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Mutharasan, Rajakkannu; Du, Guang-Wu; Miller, Jeffrey H.; Ko, Frank

    1992-01-01

    A critical mechanical system in advanced hypersonic engines is the panel-edge seal system that seals gaps between the articulating horizontal engine panels and the adjacent engine splitter walls. Significant advancements in seal technology are required to meet the extreme demands placed on the seals, including the simultaneous requirements of low leakage, conformable, high temperature, high pressure, sliding operation. In this investigation, the seal concept design and development of two new seal classes that show promise of meeting these demands will be presented. These seals include the ceramic wafer seal and the braided ceramic rope seal. Presented are key elements of leakage flow models for each of these seal types. Flow models such as these help designers to predict performance-robbing parasitic losses past the seals, and estimate purge coolant flow rates. Comparisons are made between measured and predicted leakage rates over a wide range of engine simulated temperatures and pressures, showing good agreement.

  8. Trending of Overboard Leakage of ISS Cabin Atmosphere

    NASA Technical Reports Server (NTRS)

    Schaezler, Ryan N.; Cook, Anthony J.; Leonard, Daniel J.; Ghariani, Ahmed

    2011-01-01

    The International Space Station (ISS) overboard leakage of cabin atmosphere is continually tracked to identify new or aggravated leaks and to provide information for planning of nitrogen supply to the ISS. The overboard leakage is difficult to trend with various atmosphere constituents being added and removed. Changes to nitrogen partial pressure is the nominal means of trending the overboard leakage. This paper summarizes the method of the overboard leakage trending and presents findings from the trending.

  9. Real-time relationship between PKA biochemical signal network dynamics and increased action potential firing rate in heart pacemaker cells: Kinetics of PKA activation in heart pacemaker cells.

    PubMed

    Yaniv, Yael; Ganesan, Ambhighainath; Yang, Dongmei; Ziman, Bruce D; Lyashkov, Alexey E; Levchenko, Andre; Zhang, Jin; Lakatta, Edward G

    2015-09-01

    cAMP-PKA protein kinase is a key nodal signaling pathway that regulates a wide range of heart pacemaker cell functions. These functions are predicted to be involved in regulation of spontaneous action potential (AP) generation of these cells. Here we investigate if the kinetics and stoichiometry of increase in PKA activity match the increase in AP firing rate in response to β-adrenergic receptor (β-AR) stimulation or phosphodiesterase (PDE) inhibition, that alters the AP firing rate of heart sinoatrial pacemaker cells. In cultured adult rabbit pacemaker cells infected with an adenovirus expressing the FRET sensor AKAR3, the EC50 in response to graded increases in the intensity of β-AR stimulation (by Isoproterenol) the magnitude of the increases in PKA activity and the spontaneous AP firing rate were similar (0.4±0.1nM vs. 0.6±0.15nM, respectively). Moreover, the kinetics (t1/2) of the increases in PKA activity and spontaneous AP firing rate in response to β-AR stimulation or PDE inhibition were tightly linked. We characterized the system rate-limiting biochemical reactions by integrating these experimentally derived data into a mechanistic-computational model. Model simulations predicted that phospholamban phosphorylation is a potent target of the increase in PKA activity that links to increase in spontaneous AP firing rate. In summary, the kinetics and stoichiometry of increases in PKA activity in response to a physiological (β-AR stimulation) or pharmacological (PDE inhibitor) stimuli match those of changes in the AP firing rate. Thus Ca(2+)-cAMP/PKA-dependent phosphorylation limits the rate and magnitude of increase in spontaneous AP firing rate. PMID:26241846

  10. Anastomotic leakage after anterior resection for rectal cancer with mesorectal excision: incidence, risk factors, and management.

    PubMed

    Tortorelli, Antonio Pio; Alfieri, Sergio; Sanchez, Alejandro Martin; Rosa, Fausto; Papa, Valerio; Di Miceli, Dario; Bellantone, Chiara; Doglietto, Giovanni Battista

    2015-01-01

    We investigated risk factors and prognostic implications of symptomatic anastomotic leakage after anterior resection for rectal cancer, and the influence of a diverting stoma. Our retrospective review of prospective collected data analyzed 475 patients who underwent anterior resection for rectal cancer. Uni- and multivariate analysis was made between anastomotic leakage and patient, tumor, and treatment variables, either for the overall group (n = 475) and in the midlow rectal cancer subgroup (n = 291). Overall rate of symptomatic leakage was 9 per cent (43 of 475) with no related postoperative mortality. At univariate analysis, significant factors for leak were a tumor less than 6 cm from the anal verge (13.7 vs 6.6%; P = 0.011) and intraoperative transfusions (16.9 vs 4.3%; P = 0.001). Similar results were observed in the midlow rectal cancer subgroup. At multivariate analysis, no parameter resulted in being an independent prognostic factor for risk of leakage. In patients with a leakage, a temporary enterostomy considerably reduced the need for reoperation (12.5 vs 77.8%; P < 0.0001) and the risk of a permanent stoma (18.7 vs 28.5%; P = 0.49). The incidence of anastomotic failure increases for lower tumors, whereas it is not influenced by radiotherapy. Defunctioning enterostomy does not influence the leak rate, but it mitigates clinical consequences. PMID:25569064

  11. Radiation induced inter-device leakage degradation

    NASA Astrophysics Data System (ADS)

    Hu, Zhi-Yuan; Liu, Zhang-Li; Shao, Hua; Zhang, Zheng-Xuan; Ning, Bing-Xu; Chen, Ming; Bi, Da-Wei; Zou, Shi-Chang

    2011-08-01

    The evolution of inter-device leakage current with total ionizing dose in transistors in 180 nm generation technologies is studied with an N-type poly-gate field device (PFD) that uses the shallow trench isolation as an effective gate oxide. The overall radiation response of these structures is determined by the trapped charge in the oxide. The impacts of different bias conditions during irradiation on the inter-device leakage current are studied for the first time in this work, which demonstrates that the worst condition is the same as traditional NMOS transistors. Moreover, the two-dimensional technology computer-aided design simulation is used to understand the bias dependence.

  12. Agglomeration rate and action forces between atomized particles of agglomerator and inhaled-particles from coal combustion.

    PubMed

    Wei, Feng; Zhang, Jun-ying; Zheng, Chu-guang

    2005-01-01

    In order to remove efficiently haled-particles emissions from coal combustions, a new way was used to put forward the process of agglomeration and the atomization was produced by the nozzle and then sprayed into the flue before precipitation devices of power station boiler in order to make inhaled-particles agglomerate into bigger particles, which can be easily removed but not change existing running conditions of boiler. According to this idea, a model is set up to study agglomeration rate and effect forces between fly ash inhaled-particles and atomized agglomerator particles. The developed agglomeration rate was expressed by relative particle number decreasing speed per unit volume. The result showed that viscosity force and flow resistance force give main influences on agglomeration effect of inhaled-particles, while springiness force and gravity have little effect on agglomeration effect of theirs. Factors influencing the agglomeration rate and effect forces are studied, including agglomerator concentration, agglomerator flux and agglomerator density, atomized-particles diameters and inhaled-particles diameter and so on. PMID:16295917

  13. 42 CFR 84.92 - Exhalation valve leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test. 84.92 Section 84.92... Breathing Apparatus § 84.92 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be...) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute....

  14. 42 CFR 84.92 - Exhalation valve leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Exhalation valve leakage test. 84.92 Section 84.92... Breathing Apparatus § 84.92 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be...) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute....

  15. 42 CFR 84.92 - Exhalation valve leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Exhalation valve leakage test. 84.92 Section 84.92... Breathing Apparatus § 84.92 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be...) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute....

  16. 42 CFR 84.92 - Exhalation valve leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test. 84.92 Section 84.92... Breathing Apparatus § 84.92 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be...) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute....

  17. 42 CFR 84.92 - Exhalation valve leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Exhalation valve leakage test. 84.92 Section 84.92... Breathing Apparatus § 84.92 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be...) Leakage between the valve and the valve seat shall not exceed 30 milliliters per minute....

  18. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  19. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  20. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  1. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  2. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  3. 3DHZETRN: Neutron leakage in finite objects

    NASA Astrophysics Data System (ADS)

    Wilson, John W.; Slaba, Tony C.; Badavi, Francis F.; Reddell, Brandon D.; Bahadori, Amir A.

    2015-11-01

    The 3DHZETRN formalism was recently developed as an extension to HZETRN with an emphasis on 3D corrections for neutrons and light ions. Comparisons to Monte Carlo (MC) simulations were used to verify the 3DHZETRN methodology in slab and spherical geometry, and it was shown that 3DHZETRN agrees with MC codes to the degree that various MC codes agree among themselves. One limitation of such comparisons is that all of the codes (3DHZETRN and three MC codes) utilize different nuclear models/databases; additionally, using a common nuclear model is impractical due to the complexity of the software. It is therefore difficult to ascertain if observed discrepancies are caused by transport code approximations or nuclear model differences. In particular, an important simplification in the 3DHZETRN formalism assumes that neutron production cross sections can be represented as the sum of forward and isotropic components, where the forward component is subsequently solved within the straight-ahead approximation. In the present report, previous transport model results in specific geometries are combined with additional results in related geometries to study neutron leakage using the Webber 1956 solar particle event as a source boundary condition. A ratio is defined to quantify the fractional neutron leakage at a point in a finite object relative to a semi-infinite slab geometry. Using the leakage ratio removes some of the dependence on the magnitude of the neutron production and clarifies the effects of angular scattering and absorption with regard to differences between the models. Discussion is given regarding observed differences between the MC codes and conclusions drawn about the need for further code development. Although the current version of 3DHZETRN is reasonably accurate compared to MC simulations, this study shows that improved leakage estimates can be obtained by replacing the isotropic/straight-ahead approximation with more detailed descriptions.

  4. 3DHZETRN: Neutron leakage in finite objects.

    PubMed

    Wilson, John W; Slaba, Tony C; Badavi, Francis F; Reddell, Brandon D; Bahadori, Amir A

    2015-11-01

    The 3DHZETRN formalism was recently developed as an extension to HZETRN with an emphasis on 3D corrections for neutrons and light ions. Comparisons to Monte Carlo (MC) simulations were used to verify the 3DHZETRN methodology in slab and spherical geometry, and it was shown that 3DHZETRN agrees with MC codes to the degree that various MC codes agree among themselves. One limitation of such comparisons is that all of the codes (3DHZETRN and three MC codes) utilize different nuclear models/databases; additionally, using a common nuclear model is impractical due to the complexity of the software. It is therefore difficult to ascertain if observed discrepancies are caused by transport code approximations or nuclear model differences. In particular, an important simplification in the 3DHZETRN formalism assumes that neutron production cross sections can be represented as the sum of forward and isotropic components, where the forward component is subsequently solved within the straight-ahead approximation. In the present report, previous transport model results in specific geometries are combined with additional results in related geometries to study neutron leakage using the Webber 1956 solar particle event as a source boundary condition. A ratio is defined to quantify the fractional neutron leakage at a point in a finite object relative to a semi-infinite slab geometry. Using the leakage ratio removes some of the dependence on the magnitude of the neutron production and clarifies the effects of angular scattering and absorption with regard to differences between the models. Discussion is given regarding observed differences between the MC codes and conclusions drawn about the need for further code development. Although the current version of 3DHZETRN is reasonably accurate compared to MC simulations, this study shows that improved leakage estimates can be obtained by replacing the isotropic/straight-ahead approximation with more detailed descriptions. PMID:26553635

  5. Remote Sensing And Surface Hydrocarbon Leakage

    NASA Astrophysics Data System (ADS)

    Matthews, M. D.; Jones, V. T.; Richers, D. M.

    1984-08-01

    The Geosat oil and gas test site program stimulated interest in the interaction between surface hydrocarbon concentrations and interpretation of remote sensing data. The test case results suggested that lineaments correspond to avenues of preferential hydrocarbon seepage and that this seepage affects vegetation health and populations at Patrick Draw field in Wyoming and potentially at Lost River field, West Virginia. These two areas were selected for additional surface hydrocarbon surveys in order to test these hypotheses. The Patrick Draw study shows that a zone of stressed vegetation, visible on thematic mapper data, definitely coincides with an area of marked leakage of hydrocarbons and that the composition of these gases would predict an intermediate type oil and gas reservoir such as exists in the area. The study further indicates that the leakage is in large part controlled by the presence of fractures/faults recognized as lineaments on the remote sensing images. The Lost River study specifically investigated the possible existence of hydrocarbon leakage causing anomalous populations of maple trees in a climax oak forest. These maples were first recognized by study of thematic mapper simulator data. The soil gas hydrocarbon concentrations are above average in several of the maple anomalies over the field. This supports the inference that the maples are present because they are more tolerant of soil conditions where hydrocarbon seepage is active. The crest of the field has low soil gas magnitudes, but high values occur to the updip eastern edge of the field along a fault/fracture that was detected in the seismic data. The conclusion that preferential pathways of hydrocarbon leakage are recognized in spectral and textural analysis of remote sensing data is supported by other studies and integrated into a suggested exploration/hydrocarbon migration model.

  6. Determination of Nitrogen, Phosphorus, and Potassium Release Rates of Slow- and Controlled-Release Fertilizers: Single-Laboratory Validation, First Action 2015.15.

    PubMed

    Thiex, Nancy

    2016-01-01

    A previously validated method for the determination of nitrogen release patterns of slow- and controlled-release fertilizers (SRFs and CRFs, respectively) was submitted to the Expert Review Panel (ERP) for Fertilizers for consideration of First Action Official Method(SM) status. The ERP evaluated the single-laboratory validation results and recommended the method for First Action Official Method status and provided recommendations for achieving Final Action. The 180 day soil incubation-column leaching technique was demonstrated to be a robust and reliable method for characterizing N release patterns from SRFs and CRFs. The method was reproducible, and the results were only slightly affected by variations in environmental factors such as microbial activity, soil moisture, temperature, and texture. The release of P and K were also studied, but at fewer replications than for N. Optimization experiments on the accelerated 74 h extraction method indicated that temperature was the only factor found to substantially influence nutrient-release rates from the materials studied, and an optimized extraction profile was established as follows: 2 h at 25°C, 2 h at 50°C, 20 h at 55°C, and 50 h at 60°C. PMID:26987312

  7. Atomic Oxygen Effects on Seal Leakage

    NASA Technical Reports Server (NTRS)

    Christensen, John R.; Underwood, Steve D.; Kamenetzky, Rachel R.; Vaughn, Jason A.

    1999-01-01

    Common Berthing Mechanism (CBM provides the structural interface between separate International Space Station (ISS) elements, such as the Laboratory and Node modules. The CBM consists of an active and a passive half that join together with structural bolts. The seal at this interface is the CBM-to-CBM molded seal. The CBM-to-CBM interface is assembled on orbit, thus the seals can be exposed to the space environment for up to 65 hours. Atomic Oxygen/Vacuum Ultraviolet radiation (AO/VUV) in space is a potential hazard to the seals. Testing was conducted to determine the effect on leakage of the CBM-to-CBM seal material exposed to AO/VUV. The sealing materials were S383 silicone and V835 fluorocarbon material. Control samples, which were not exposed to the AO/VUV environment, were used to ensure that ff any changes in leakage occurred, they could be attributed to the AO/VUV exposure. After exposure to the AO/VUV environment the leakage increase was dramatic for the fluorocarbon. This testing was a major contributing factor in selecting silicone as the CBM-to-CBM seal material.

  8. Time reversal technique for gas leakage detection.

    PubMed

    Maksimov, A O; Polovinka, Yu A

    2015-04-01

    The acoustic remote sensing of subsea gas leakage traditionally uses sonars as active acoustic sensors and hydrophones picking up the sound generated by a leak as passive sensors. When gas leaks occur underwater, bubbles are produced and emit sound at frequencies intimately related to their sizes. The experimental implementation of an acoustic time-reversal mirror (TRM) is now well established in underwater acoustics. In the basic TRM experiment, a probe source emits a pulse that is received on an array of sensors, time reversed, and re-emitted. After time reversal, the resulting field focuses back at the probe position. In this study, a method for enhancing operation of the passive receiving system has been proposed by using it in the regime of TRM. Two factors, the local character of the acoustic emission signal caused by the leakage and a resonant nature of the bubble radiation at their birth, make particularly effective scattering with the conjugate wave (CW). Analytical calculations are performed for the scattering of CW wave on a single bubble when CW is formed by bubble birthing wail received on an array, time reversed, and re-emitted. The quality of leakage detection depends on the spatio-temporal distribution of ambient noise. PMID:25920866

  9. Gaseous hydrogen leakage optical fibre detection system

    NASA Astrophysics Data System (ADS)

    Trouillet, Alain; Veillas, Colette; Sigronde, E.; Gagnaire, Henri; Clement, Michel

    2004-06-01

    Liquid hydrogen has been intensively used in aerospace applications during the past forty years and is of great interest for fuel cells technologies and future automotive applications. Following upon major explosive risks due to the use of hydrogen in air, previous studies were carried out in our laboratory in order to develop optical fiber sensors for the detection of hydrogen leakage. This communication is aimed towards a prototype optical fiber system designed for the detection of gaseous hydrogen leakage near the conecting flanges of the liquid hydrogen pipes on the test bench of the engine Vulcain of the rocket ARIANE V. Depending on the configuration, the prototype sensor provides a two-level alarm signal and the detection of gaseous hydrogen leakage is possible for concentrations lower than the lower explosive limit in air (between 0.1 and 4%) with alarm response times lower than 10 seconds in a wide range of temperatures between -35°C and 300°C. The sensing principle based on palladium-hydrogen interaction is presented as well as the detection system composed of an optical fiber probe and an optoelectronic device.

  10. Atomic Oxygen Effects on Seal Leakage

    NASA Technical Reports Server (NTRS)

    Christensen, John R.; Underwood, Steve D.; Kamenetzky, Rachel R.; Vaughn, Jason A.

    1998-01-01

    Common Berthing Mechanism (CBM) provides the structural interface between separate International Space Station (ISS) elements, such as the Laboratory and Node modules. The CBM consists of an active and a passive half that join together with structural bolts. The seal at this interface is the CBM-to-CBM molded seal. The CBM-to-CBM interface is assembled on orbit, thus the seals can be exposed to the space environment for up to 65 hours. Atomic Oxygen/Vacuum Ultraviolet radiation (AO/VUV) in space is a potential hazard to the seals. Testing was conducted to determine the effect on leakage of the CBM-to-CBM seal material exposed to AO/VUV. The sealing materials were S383 silicone and V835 fluorocarbon material. Control samples, which were not exposed to the AO/VUV environment, were used to ensure that if any changes in leakage occurred, they could be attributed to the AO/VUV exposure. After exposure to the AO/VUV environment the leakage increase was dramatic for the fluorocarbon. This testing was a major contributing factor in selecting silicone as the CBM-to-CBM seal material.

  11. Chemical stress and metabolic rate in aquatic invertebrates: Threshold, dose-response relationships, and mode of toxic action

    SciTech Connect

    Penttinen, O.P.; Kukkonen, J.

    1998-01-01

    Four automatic compounds were evaluated in laboratory studies to investigate their accumulation and toxicant-induced changes in the rate of heat dissipation in the freshwater invertebrates Chironomus riparius and Lumbriculus variegatus. The sublethal energetic response detected by direct calorimetry was related to tissue chemical concentration by the threshold model and an attempt was made to apply the critical body residue (CBR) concept. Below the compound-specific tissue threshold concentration or CBR, no correlations were found between the dose and the metabolic rate, and the slopes of the regression were close to zero. Above the threshold, depending on the chemical, metabolic rate either increased or decreased. An increase in heat output produced by 2,4-dinitrophenol (2,4-DNP), pentachlorophenol (PCP), and 2,4,5-trichlorophenol (2,4,5-TCP) was closely correlated with the dose. The order of toxicity for these phenols was 2,4-DNP = PCP > 2,4,5-TCP, which reflects the interaction of compounds` lipophilicities and acidities and their combined influence on bioaccumulation and effects on the energy-transducing membrane by uncoupling oxidative phosphorylation. A decrease in the heat output caused by 1,2,4-trichlorobenzene (1,2,4-TCB) was more variable relative to dose. Also, 1,2,4-TCB required a much higher molar tissue threshold concentration ({approximately}2.0 {micro}mol/g wet weight) than required by phenols to generate the response. Both the metabolic response and the chemical threshold value were those expected to result from narcosis. Results suggest that calorimetric measures can identify not only the integrated physiologic response but also have some resolution of the mechanism of toxic effects.

  12. A Clinical Parameters-Based Model Predicts Anastomotic Leakage After a Laparoscopic Total Mesorectal Excision

    PubMed Central

    Hu, Xiang; Cheng, Yong

    2015-01-01

    Abstract Anastomotic leakage after colorectal surgery is a major and life-threatening complication that occurs more frequently than expected. Intraoperative judgment in predicting potential leakage has shown extremely low sensitivity and specificity. The lack of a model for predicting anastomotic leakage might explain this insufficient judgment. We aimed to propose a clinical parameters-based model to predict anastomotic leakage after laparoscopic total mesorectal excision (TME). This study was a retrospective analysis of a prospectively designed colorectal cancer dataset. In total, 1968 patients with a laparoscopic TME were enrolled from November 1, 2010, to March 20, 2014. The independent risk factors for anastomotic leakage were identified, from which the parameters-based model for leakage was developed. Anastomotic leakage was noted in 63 patients (3.2%). Male sex, a low level of anastomosis, intraoperative blood loss, diabetes, the duration time of the surgery, and low temperature were significantly associated by the bivariate analysis and the Cochran–Mantel–Haenszel test with an increased risk. From these factors, the logistic regression model identified the following 4 independent predictors: male sex (risk ratio [RR] = 1.85, 95% confidence interval [CI]: 1.13–4.87), diabetes (RR = 2.08, 95% CI: 1.19–5.8), a lower anastomosis level (RR = 3.41, 95% CI: 1.17–6.71), and a high volume of blood loss (RR = 1.03, 95% CI: 1.01–1.05). The locally weighted scatterplot smoothing regression showed an anastomosis within 5 cm from the anus and intraoperative blood loss of >100 mL as the cutoff values for a significantly increased risk of leakage. Based on these independent factors, a parameters-based model was established by the regression coefficients. The high and low-risk groups were classified according to scores of 3–5 and 0–2, with leakage rates of 8.57% and 1.66%, respectively (P < 0.001). This parameters-based model could

  13. The influence of muscle action on heart rate, RPE, and affective responses after upper-body resistance exercise.

    PubMed

    Miller, Paul C; Hall, Eric E; Chmelo, Elizabeth A; Morrison, Jeffrey M; DeWitt, Rachel E; Kostura, Christine M

    2009-03-01

    Ratings of perceived exertion (RPE) are routinely used to monitor, assess, and prescribe aerobic exercise. Heart rate (HR) is another measure used to evaluate exercise intensity. Additionally, affective responses to aerobic exercise have been studied and seem to be influenced by the intensity of the exercise. The perceptual, HR, and affective responses to resistance exercise have not been effectively established. The purpose of this study was to examine whether differences in affect, RPE, and HR exist among college-aged women (n = 31) performing three different modes of resistance training: concentric (CE), eccentric (EE), and traditional concentric/eccentric (TE) performed at varying resistances. The women were asked to complete four sessions of resistance training on variable resistance machines: chest press, seated row, overhead press, and biceps curl. The first session was used to establish the 10-repetition maximum (RM) load for each station. Subsequent sessions involved the execution of training in one of the three test conditions: CE, EE, or TE. The participants performed three sets of each lift at 80% 10-RM, 100% 10-RM, and 120% 10-RM. The data revealed lower RPE during EE than the other test conditions. Similarly, EE elicited more mild HR response than either CE or TE. This finding is potentially important for the establishment of training programs, especially for those individuals recovering from an illness, who had been previously sedentary, and who are involved in rehabilitation of an injury. PMID:19204573

  14. Heparin Leakage in Central Venous Catheters by Hemodynamic Transport

    NASA Astrophysics Data System (ADS)

    Barbour, Michael; McGah, Patrick; Gow, Kenneth; Aliseda, Alberto

    2014-11-01

    Central venous catheters (CVCs), placed in the superior vena cava for hemodialysis, are routinely filled with heparin, an anticoagulant, while not in use to maintain patency and prevent thrombus formation at the catheter tip. However, the heparin-lock procedure places the patient at risk for systemic bleeding incidences, as heparin is known to leak into the blood stream. We propose that the driving mechanism behind heparin leakage is advective-diffusive transport due to the pulsatile blood flow surrounding the catheter tip. This novel hypothesis is based on Planar Laser Induced Fluorescence (PLIF) measurements of heparin transport from a CVC placed inside an in vitro pulsatile flow loop and validated with CFD simulations. The results show an initial, fast (<10s), advection-dominated phase that rapidly depletes the concentration of heparin at the CVC tip, followed by a slow, diffusion-limited phase inside the catheter lumen, where concentration is still high, that is insufficient at replenishing the lost heparin at the tip. These results, which estimate leakage rates consistent with published in vivo data, predict that the concentration of heparin at the catheter tip is effectively zero for the majority of the interdialytic phase, rendering the heparin lock ineffective.

  15. A reactive transport model for the geochemical response, detection and potential mitigation of CO2 leakage into a confined aquifer

    NASA Astrophysics Data System (ADS)

    Maher, K.; Druhan, J. L.; Vialle, S.; Benson, S. M.; Agarwal, A.

    2013-12-01

    Long-term storage of anthropogenic CO2 in the subsurface generally assumes that caprock formations will serve as physical barriers to upward migration of CO2. Stability and coherence of the caprocks are thus important criteria for site selection, but caprock integritycannot be guaranteed with total certainty over the lifetime of the project. As a result, carbon capture and storage projects require reliable techniques to monitor geologic storage sites for newly formed leaks, and the ability to rapidly deploy mitigation measures should leakage occur. Here, we present two-dimensional reactive transport simulations to evaluate the hydrogeochemical characteristics of a newly formed CO2 leak into an overlying reservoir. Simulations use the ToughReact multi-component reactive transport code and hypothetical reservoir characteristics. We focus on the comparatively short time period of days to months following formation of the leak to consider (1) geochemical shifts in formation water indicative of the leak, (2) hydrodynamics of pumping wells in the vicinity of the leak, and (3) delivery of a sealant to the leak through an adjacent well bore. Our results suggest that characteristic shifts in pH and dissolved inorganic carbon might be detected in down-gradient mentoring wells prior to the breakthrough of CO2, and could offer a potential means of identifying small and newly formed leaks. Injecting water into the aquifer through pumping wells in the vicinity of the leak provides a hydrodynamic control that can prevent CO2 from reaching the top of the reservoir, but this action will likely have only minor influence on the rate of leakage through the caprock defect. Injection of a hypothetical sealant through an adjacent pumping well is considered using an aqueous solute with pH-dependent equilibrium constraints such that the species is soluble in the basic pH range but forms a precipitate at neutral to acidic pH conditions associated with CO2-rich water. Injection of this

  16. Antimicrobial Peptide Lactoferricin B-Induced Rapid Leakage of Internal Contents from Single Giant Unilamellar Vesicles.

    PubMed

    Moniruzzaman, Md; Alam, Jahangir Md; Dohra, Hideo; Yamazaki, Masahito

    2015-09-29

    Enzymatic digestion of bovine lactoferrin generates lactoferricin B (Lfcin B), a 25-mer peptide with strong antimicrobial activity of unknown mechanism. To elucidate the mechanistic basis of Lfcin B bactericidal activity, we investigated the interaction of Lfcin B with Escherichia coli and liposomes of lipid membranes. Lfcin B induced the influx of a membrane-impermeant fluorescent probe, SYTOX green, from the outside of E. coli into its cytoplasm. Lfcin B induced gradual leakage of calcein from large unilamellar vesicles (LUVs) of dioleoylphosphatidylglycerol (DOPG)/dioleoylphosphatidylcholine (DOPC) membranes. To clarify the cause of Lfcin B-induced leakage of calcein from the LUVs, we used the single giant unilamellar vesicle (GUV) method to investigate the interaction of Lfcin B with calcein-containing DOPG/DOPC-GUVs. We observed that a rapid leakage of calcein from a GUV started stochastically; statistical analysis provided a rate constant for Lfcin B-induced pore formation, kp. On the other hand, phase-contrast microscopic images revealed that Lfcin B induced a rapid leakage of sucrose from the single GUVs with concomitant appearance of a spherical GUV of smaller diameter. Because of the very fast leakage, and at the present time resolution of the experiments (33 ms), we could not follow the evolution of pore nor the process of the structural changes of the GUV. Here we used the term "local rupture" to express the rapid leakage of sucrose and determined the rate constant of local rupture, kL. On the basis of the comparison between kp and kL, we concluded that the leakage of calcein from single GUVs occurred as a result of a local rupture in the GUVs and that smaller pores inducing leakage of calcein were not formed before the local rupture. The results of the effect of the surface charge density of lipid membranes and that of salt concentration in buffer on kp clearly show that kp increases with an increase in the extent of electrostatic interactions due to

  17. A quantitative methodology to assess the risks to human health from CO 2 leakage into groundwater

    NASA Astrophysics Data System (ADS)

    Siirila, Erica R.; Navarre-Sitchler, Alexis K.; Maxwell, Reed M.; McCray, John E.

    2012-02-01

    Leakage of CO 2 and associated gases into overlying aquifers as a result of geologic carbon capture and sequestration may have adverse impacts on aquifer drinking-water quality. Gas or aqueous-phase leakage may occur due to transport via faults and fractures, through faulty well bores, or through leaky confining materials. Contaminants of concern include aqueous salts and dissolved solids, gaseous or aqueous-phase organic contaminants, and acidic gas or aqueous-phase fluids that can liberate metals from aquifer minerals. Here we present a quantitative risk assessment framework to predict potential human health risk from CO 2 leakage into drinking water aquifers. This framework incorporates the potential release of CO 2 into the drinking water aquifer; mobilization of metals due to a decrease in pH; transport of these metals down gradient to municipal receptors; distributions of contaminated groundwater to multiple households; and exposure and health risk to individuals using this water for household purposes. Additionally, this framework is stochastic, incorporates detailed variations in geological and geostatistical parameters and discriminates between uncertain and variable parameters using a two-stage, or nested, Monte Carlo approach. This approach is demonstrated using example simulations with hypothetical, yet realistic, aquifer characteristics and leakage scenarios. These example simulations show a greater risk for arsenic than for lead for both cancer and non-cancer endpoints, an unexpected finding. Higher background groundwater gradients also yield higher risk. The overall risk and the associated uncertainty are sensitive to the extent of aquifer stratification and the degree of local-scale dispersion. These results all highlight the importance of hydrologic modeling in risk assessment. A linear relationship between carcinogenic and noncarcinogenic risk was found for arsenic and suggests action levels for carcinogenic risk will be exceeded in exposure

  18. FELERION: a new approach for leakage power reduction

    NASA Astrophysics Data System (ADS)

    R, Anjana; Somkuwar, Ajay

    2014-12-01

    The circuit proposed in this paper simultaneously reduces the sub threshold leakage power and saves the state of art aspect of the logic circuits. Sleep transistors and PMOS-only logic are used to further reduce the leakage power. Sleep transistors are used as the keepers to reduce the sub threshold leakage current providing the low resistance path to the output. PMOS-only logic is used between the pull up and pull down devices to mitigate the leakage power further. Our proposed fast efficient leakage reduction circuit not only reduces the leakage current but also reduces the power dissipation. Power and delay are analyzed at the 32 nm BSIM4 model for a chain of four inverters, NAND, NOR and ISCAS-85 c17 benchmark circuits using DSCH3 and the Microwind tool. The simulation results reveal that our proposed approach mitigates leakage power by 90%-94% as compared to the conventional approach.

  19. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Delgado, Irebert R.

    2004-01-01

    Advanced brush and finger seal technologies offer reduced leakage rates over conventional labyrinth seals used in gas turbine engines. To address engine manufacturers concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature Turbine Seal Test Rig. Leakage and power loss test results are compared for these competing seals for operating conditions up to 922 K (1200 F) inlet air temperature, 517 KPa (75 psid) across the seal, and surface velocities up to 366 m/s (1200 ft/s).

  20. Can intraluminal devices prevent or reduce colorectal anastomotic leakage: A review

    PubMed Central

    Morks, Annelien N; Havenga, Klaas; Ploeg, Rutger J

    2011-01-01

    Colorectal anastomotic leakage is a serious complication of colorectal surgery, leading to high morbidity and mortality rates. In recent decades, many strategies aimed at lowering the incidence of anastomotic leakage have been examined. The focus of this review will be on mechanical aids protecting the colonic anastomosis against leakage. A literature search was performed using MEDLINE, EMBASE, and The Cochrane Collaborative library for all papers related to prevention of anastomotic leakage by placement of a device in the colon. Devices were categorised as decompression devices, intracolonic devices, and biodegradable devices. A decompression device functions by keeping the anal sphincter open, thereby lowering the intraluminal pressure and lowering the pressure on the anastomosis. Intracolonic devices do not prevent the formation of dehiscence. However, they prevent the faecal load from contacting the anastomotic site, thereby preventing leakage of faeces into the peritoneal cavity. Many attempts have been made to find a device that decreases the incidence of AL; however, to date, none of the devices have been widely accepted. PMID:22110276

  1. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    NASA Technical Reports Server (NTRS)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in.), a fence height of 0.0635 cm (0.025 in.), and 1800 bristles/cm circumference (4500 bristles/in. circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approximately the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  2. Brush seal leakage performance with gaseous working fluids at static and low rotor speed conditions

    NASA Technical Reports Server (NTRS)

    Carlile, Julie A.; Hendricks, Robert C.; Yoder, Dennis A.

    1992-01-01

    The leakage performance of a brush seal with gaseous working fluids at static and low rotor speed conditions was studied. The leakage results are included for air, helium, and carbon dioxide at several bristle/rotor interferences. Also, the effects of packing a lubricant into the bristles and also of reversing the pressure drop across the seal were studied. Results were compared to that of an annular seal at similar operating conditions. In order to generalize the results, they were correlated using corresponding state theory. The brush seal tested had a bore diameter of 3.792 cm (1.4930 in), a fence height of 0.0635 cm (0.025 in), and 1800 bristles/cm circumference (4500 bristles/in circumference). Various bristle/rotor radial interferences were achieved by using a tapered rotor. The brush seal reduced the leakage in comparison to the annular seal, up to 9.5 times. Reversing the pressure drop across the brush seal produced leakage rates approx. the same as that of the annular seal. Addition of a lubricant reduced the leakage by 2.5 times. The air and carbon dioxide data were successfully correlated using corresponding state theory. However, the helium data followed a different curve than the air and carbon dioxide data.

  3. Extensive paternal mtDNA leakage in natural populations of Drosophila melanogaster

    PubMed Central

    Nunes, Maria D S; Dolezal, Marlies; Schlötterer, Christian

    2013-01-01

    Strict maternal inheritance is considered a hallmark of animal mtDNA. Although recent reports suggest that paternal leakage occurs in a broad range of species, it is still considered an exceptionally rare event. To evaluate the impact of paternal leakage on the evolution of mtDNA, it is essential to reliably estimate the frequency of paternal leakage in natural populations. Using allele-specific real-time quantitative PCR (RT-qPCR), we show that heteroplasmy is common in natural populations with at least 14% of the individuals carrying multiple mitochondrial haplotypes. However, the average frequency of the minor mtDNA haplotype is low (0.8%), which suggests that this pervasive heteroplasmy has not been noticed before due to a lack of power in sequencing surveys. Based on the distribution of mtDNA haplotypes in the offspring of heteroplasmic mothers, we found no evidence for strong selection against one of the haplotypes. We estimated that the rate of paternal leakage is 6% and that at least 100 generations are required for complete sorting of mtDNA haplotypes. Despite the high proportion of heteroplasmic individuals in natural populations, we found no evidence for recombination between mtDNA molecules, suggesting that either recombination is rare or recombinant haplotypes are counter-selected. Our results indicate that evolutionary studies using mtDNA as a marker might be biased by paternal leakage in this species. PMID:23452233

  4. Sex-specific action of insulin to acutely increase the metabolic clearance rate of dehydroepiandrosterone in humans.

    PubMed Central

    Nestler, J E; Kahwash, Z

    1994-01-01

    To test the hypothesis that insulin acutely enhances the metabolic clearance rate (MCR) of dehydroepiandrosterone in humans, the effect of a short-term insulin infusion on the MCR of dehydroepiandrosterone was assessed in 10 men and 7 women. After an overnight fast, dehydroepiandrosterone was infused at 3.47 mumol/h for 6.5 h. At 240 min, a hyperinsulinemic-euglycemic clamp was begun by infusing insulin at 21.5 pmol/kg per min for 2.5 h. MCR of dehydroepiandrosterone was calculated at baseline (210-240 min) and during the insulin infusion (360-390 min). A control study was conducted at least 1 wk later, in which 0.45% saline was substituted for the hyperinsulinemic-euglycemic clamp. During the insulin clamp study, serum insulin rose from 34 +/- 2 to 1084 +/- 136 pmol/liter (P = 0.0001) in men and from 40 +/- 5 to 1357 +/- 175 pmol/liter (P = 0.0003) in women, while serum glucose remained constant in both groups. MCR of dehydroepiandrosterone rose in men during the insulin infusion from 2443 +/- 409 to 3599 +/- 500 liters/24 h (P = 0.003), but did not change during the control saline infusion. In contrast, MCR of dehydroepiandrosterone in women did not change in the insulin clamp study during insulin infusion (2526 +/- 495 liters/24 h at baseline vs. 2442 +/- 491 liters/24 h during insulin infusion; P = 0.78). These findings suggest that insulin acutely increases the MCR of dehydroepiandrosterone in men but not in women. PMID:7929824

  5. A ray tracing study of shock leakage in a model supersonic jet

    NASA Astrophysics Data System (ADS)

    Shariff, Karim; Manning, Ted A.

    2013-07-01

    Recent work has described screech noise from a supersonic jet as being due to leakage of a wave that is otherwise trapped in the jet's interior. In that work, the simplest of many techniques used is ray tracing for a single shear-layer modeled as a row of Stuart vortices. In the present work, a lower row of vortices is added to form a plane jet. Instead of plotting ray paths, a technique of visualization analogous to streaklines is used that better corresponds to instantaneous density fields as observed, for instance, by the Schlieren method. This produces striking images that show leakage of waves at each internal reflection resulting in a row of acoustic sources as envisioned since the 1950s. However, the sources are not isotropic and each has a zone of silence in the downstream direction. Leakage creates a fold in the wave pattern internal to the jet which leads to fine scale features. Reported experiments have also observed fine scale features (described as splitting) in the shock-cell pattern; they may be related to those observed here. Internally reflected rays also undergo a diffusive process as they propagate down the jet. In particular, each successive internal reflection at an unsteady shear-layer scatters rays along a wider range of wave angle and makes them more susceptible to leakage at the next reflection. It also causes more downstream directivity for the more downstream sources. An important result is that as the Mach number Mj is varied, maxima in leakage rate and mean acoustic amplitude occur at (near) resonances between the Mach-wave and shear-layer periods. Maxima in sound pressure level versus Mj have also been reported for laboratory round jets. Finally, as the shear-layer thickness is increased, a minimum in the rate of leakage (correlated with a minimum in radiation amplitude) occurs due to the competing effects of increased shear-layer penetration versus reduced eddy passage frequency.

  6. EVA Suit Microbial Leakage Investigation Project

    NASA Technical Reports Server (NTRS)

    Falker, Jay; Baker, Christopher; Clayton, Ronald; Rucker, Michelle

    2016-01-01

    The objective of this project is to collect microbial samples from various EVA suits to determine how much microbial contamination is typically released during simulated planetary exploration activities. Data will be released to the planetary protection and science communities, and advanced EVA system designers. In the best case scenario, we will discover that very little microbial contamination leaks from our current or prototype suit designs, in the worst case scenario, we will identify leak paths, learn more about what affects leakage--and we'll have a new, flight-certified swab tool for our EVA toolbox.

  7. Continued Investigation of Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    NASA Technical Reports Server (NTRS)

    Delgado, Irebert R.; Proctor, Margaret P.

    2006-01-01

    Secondary seal leakage in jet engine applications results in power losses to the engine cycle. Likewise, seal power loss in jet engines not only result in efficiency loss but also increase the heat input into the engine resulting in reduced component lives. Experimental work on labyrinth and annular seals was performed at NASA Glenn Research Center to quantify seal leakage and power loss at various temperatures, seal pressure differentials, and surface speeds. Data from annular and labyrinth seals are compared with previous brush and finger seal test results. Data are also compared to literature. Annular and labyrinth seal leakage rates are 2 to 3 times greater than brush and finger seal rates. Seal leakage decreases with increasing speed but increases with increasing test temperature due to thermal expansion mismatch. Also seal power loss increases with surface speed, seal pressure differential, mass flow rate, and radial clearance. Annular and labyrinth seal power losses were higher than those of brush or finger seal data. The brush seal power loss was 15 to 30 percent lower than annular and labyrinth seal power loss.

  8. Predicting Envelope Leakage in Attached Dwellings (Fact Sheet)

    SciTech Connect

    Not Available

    2013-11-01

    The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this "solo" test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. Although minimizing leakage to neighboring units is highly recommended to avoid indoor air quality issues between units, reduce pressure differentials between units, and control stack effect, the energy benefits of air sealing can be significantly overpredicted if the solo air leakage number is used in the energy analysis. Guarded blower door testing is more appropriate for isolating and measuring leakage to the outside in attached housing. This method uses multiple blower doors to depressurize adjacent spaces to the same level as the unit being tested. Maintaining a neutral pressure across common walls, ceilings, and floors acts as a "guard" against air leakage between units. The resulting measured air leakage in the test unit is only air leakage to the outside. Although preferred for assessing energy impacts, the challenges of performing guarded testing can be daunting.

  9. On leakage and seepage from geological carbon sequestration sites

    SciTech Connect

    Oldenburg, C.M.; Unger, A.J.A.; Hepple, R.P.; Jordan, P.D.

    2002-07-18

    Geologic carbon sequestration is one strategy for reducing the rate of increase of global atmospheric carbon dioxide (CO{sub 2} ) concentrations (IEA, 1997; Reichle, 2000). As used here, the term geologic carbon sequestration refers to the direct injection of supercritical CO{sub 2} deep into subsurface target formations. These target formations will typically be either depleted oil and gas reservoirs, or brine-filled permeable formations referred to here as brine formations. Injected CO{sub 2} will tend to be trapped by one or more of the following mechanisms: (1) permeability trapping, for example when buoyant supercritical CO{sub 2} rises until trapped by a confining caprock; (2) solubility trapping, for example when CO{sub 2} dissolves into the aqueous phase in water-saturated formations, or (3) mineralogic trapping, such as occurs when CO{sub 2} reacts to produce stable carbonate minerals. When CO{sub 2} is trapped in the subsurface by any of these mechanisms, it is effectively sequestered away from the atmosphere where it would otherwise act as a greenhouse gas. The purpose of this report is to summarize our work aimed at quantifying potential CO{sub 2} seepage due to leakage from geologic carbon sequestration sites. The approach we take is to present first the relevant properties of CO{sub 2} over the range of conditions from the deep subsurface to the vadose zone (Section 2), and then discuss conceptual models for how leakage might occur (Section 3). The discussion includes consideration of gas reservoir and natural gas storage analogs, along with some simple estimates of seepage based on assumed leakage rates. The conceptual model discussion provides the background for the modeling approach wherein we focus on simulating transport in the vadose zone, the last potential barrier to CO{sub 2} seepage (Section 4). Because of the potentially wide range of possible properties of actual future geologic sequestration sites, we carry out sensitivity analyses by

  10. Circadian response of annual weeds in a natural setting to high and low application rates of four herbicides with different modes of actions.

    PubMed

    Miller, Ryan P; Martinson, Krishona B; Sothern, Robert B; Durgan, Beverly R; Gunsolus, Jeffrey L

    2003-03-01

    Four herbicides [glyphosate (GLYT), an amino acid synthesis inhibitor; glufosinate (GLUF), a glutamine synthetase inhibitor; fomesafen (FOME), a protoporphyrinogen oxidase inhibitor, and chlorimuron ethyl (CLIM), an acetolactate synthase inhibitor] were used to examine the influence of time of day of application on the control of a variety of annual broadleaf weeds in field studies conducted in Minnesota (five studies on GLYT and GLUF, three studies on FOME and CLIM). All herbicides were applied with an adjuvant at recommended high and low (half or quarter strength) rates every 3h between 06:00 and 24:00h local time. Visual ratings of percent weed control evaluated at 14d were analyzed by herbicide and application rate for each study and across studies for time-of-day effect by analysis of variance (ANOVA) and single cosinor. A circadian response to each herbicide was found, with greatest weed control observed between 09:00 and 18:00h. Increasing the herbicide application rate did not overcome the time-of-day effect (ANOVA: p < or = 0.008 for time-of-day effect for each herbicide and application rate). The least-squares fit of a 24h cosine was significant (p < or = 0.001) for each herbicide and application rate, with double amplitudes of 18-82% (units = % visual control) and estimated peaks (acrophases) near midday between 12:40 and 13:35h. Analysis of residuals obtained from multiple regression that included weed height, herbicide rate, temperature, and relative humidity as independent factors also found a significant time-effect by both ANOVA and cosinor for each herbicide and rate, with acrophases advancing significantly by 3 to 7h for GLYT and GLUF, but not for FOME or CLIM. These results suggest that the four herbicides, while belonging to different families with different modes of action, may reveal different peak times of efficacy when adjusting for environmental factors. Nonetheless, each displays similar circadian patterns when influenced by these factors

  11. EM information leakage from display unit and visual inspection for its leakage source

    NASA Astrophysics Data System (ADS)

    Watanabe, Takashi; Sako, Hiroshi

    2013-05-01

    Display unit emits a small amount of electromagnetic wave. Although it is weak enough to prevent interference with human body, information leaks through it. This paper presents an experiment on exploring the leakage source by visually inspecting the screen images reconstructed from captured electromagnetic waves. Additionally, some countermeasures are investigated to avoid the problem.

  12. Apical leakage of four endodontic sealers.

    PubMed

    Pommel, Ludovic; About, Imad; Pashley, David; Camps, Jean

    2003-03-01

    The purpose of this study was to evaluate the sealing properties of four root canal sealers. Forty-eight maxillary central incisors were instrumented with Profile rotary instruments. They were randomly divided into four groups (n = 12) and filled using lateral condensation with one of the four sealers: Sealapex, Pulp Canal Sealer, AH 26, and Ketac-Endo. The apical leakage was measured with a fluid filtration method and expressed as L s(-1) KPa(-1). The teeth filled with Sealapex displayed a higher apical leakage (8.42 +/- 4.2 10(-11) L s(-1) KPa(-1)) than those filled with AH 26 (2.10 +/- 1.39 10(-11) L s(-1) KPa(-1)), Pulp Canal Sealer (0.17 +/- 0.09 10(-11) L s(-1) KPa(-1)) or Ketac-Endo (0.32 +/- 0.24 10(-1) L s(-1) KPa(-1)) (p < 0.01). No statistically significant difference was found among AH 26, Pulp Canal Sealer, and Ketac-Endo. No correlation was found between the sealing efficiency of the four sealers and their adhesive properties recorded in a previous study. PMID:12669883

  13. Optical imaging to map blood-brain barrier leakage

    NASA Astrophysics Data System (ADS)

    Jaffer, Hayder; Adjei, Isaac M.; Labhasetwar, Vinod

    2013-11-01

    Vascular leakage in the brain is a major complication associated with brain injuries and certain pathological conditions due to disruption of the blood-brain barrier (BBB). We have developed an optical imaging method, based on excitation and emission spectra of Evans Blue dye, that is >1000-fold more sensitive than conventional ultraviolet spectrophotometry. We used a rat thromboembolic stroke model to validate the usefulness of our method for vascular leakage. Optical imaging data show that vascular leakage varies in different areas of the post-stroke brain and that administering tissue plasminogen activator causes further leakage. The new method is quantitative, simple to use, requires no tissue processing, and can map the degree of vascular leakage in different brain locations. The high sensitivity of our method could potentially provide new opportunities to study BBB leakage in different pathological conditions and to test the efficacy of various therapeutic strategies to protect the BBB.

  14. Bystander Effects Induced by Continuous Low-Dose-Rate {sup 125}I Seeds Potentiate the Killing Action of Irradiation on Human Lung Cancer Cells In Vitro

    SciTech Connect

    Chen, H.H. Jia, R.F.; Yu, L.; Zhao, M.J.; Shao, C.L.; Cheng, W.Y.

    2008-12-01

    Purpose: To investigate bystander effects of low-dose-rate (LDR) {sup 125}I seed irradiation on human lung cancer cells in vitro. Methods and Materials: A549 and NCI-H446 cell lines of differing radiosensitivity were directly exposed to LDR {sup 125}I seeds irradiation for 2 or 4 Gy and then cocultured with nonirradiated cells for 24 hours. Induction of micronucleus (MN), {gamma}H2AX foci, and apoptosis were assayed. Results: After 2 and 4 Gy irradiation, micronucleus formation rate (MFR) and apoptotic rate of A549 and NCI-H446 cells were increased, and the MFR and apoptotic rate of NCI-H446 cells was 2.1-2.8 times higher than that of A549 cells. After coculturing nonirradiated bystander cells with {sup 125}I seed irradiated cells for 24 hours, MFR and the mean number of {gamma}H2AX foci/cells of bystander A549 and NCI-H446 cells were similar and significantly higher than those of control (p <0.05), although they did not increase with irradiation dose. However, the proportion of bystander NCI-H446 cells with MN numbers {>=}3 and {gamma}H2AX foci numbers 15-19 and 20-24 was higher than that of bystander A549 cells. In addition, dimethyl sulfoxide (DMSO) treatment could completely suppress the bystander MN of NCI-H446 cells, but it suppressed only partly the bystander MN of A549 cells, indicating that reactive oxygen species are involved in the bystander response to NCI-H446 cells, but other signaling factors may contribute to the bystander response of A549 cells. Conclusions: Continuous LDR irradiation of {sup 125}I seeds could induce bystander effects, which potentiate the killing action on tumor cells and compensate for the influence of nonuniform distribution of radiation dosage on therapeutic outcomes.

  15. Respirator leakage in the pharmaceutical industry of northwest England.

    PubMed

    Burgess, G L; Mashingaidze, M T

    1999-11-01

    Field qualitative fit tests were conducted at 10 separate companies in the Northwest of England to determine the proportion of leaking respirators in a cross-section of pharmaceutical manufacturing industries. The 3 M FT-10 Qualitative Fit Test Apparatus was used to test a total of 211 half-face particulate respirator wearers. Participants wore their own respirators and were asked to don them as they would normally. In all cases, no specific intervention had occurred prior to testing. Results indicated a failure rate of 69% (of the 211 subjects tested, 145 respirators were leaking). Successful results were not associated with the frequency of use (p = 0.71) or years of experience wearing respirators (p = 0.59). Similarly, successful results were not associated with respirator training in the current job (p = 0.38) or training in previous jobs (p = 0.49). Leakage was not consistent across the 10 companies, with two companies exhibiting a 100% failure rate while another company had 26 successful tests in 50 wearers (52% pass rate). Only 35 of the 211 participants performed a negative pressure test. Of these, 80% successfully passed the test, which was significantly greater than the 22% pass rate among those who had not performed the pressure test (p < 0.001). PMID:10616324

  16. Study on the leakage flow through a clearance gap between two stationary walls

    NASA Astrophysics Data System (ADS)

    Zhao, W.; Billdal, J. T.; Nielsen, T. K.; Brekke, H.

    2012-11-01

    In the present paper, the leakage flow in the clearance gap between stationary walls was studied experimentally, theoretically and numerically by the computational fluid dynamics (CFD) in order to find the relationship between leakage flow, pressure difference and clearance gap. The experimental set-up of the clearance gap between two stationary walls is the simplification of the gap between the guide vane faces and facing plates in Francis turbines. This model was built in the Waterpower laboratory at Norwegian University of Science and Technology (NTNU). The empirical formula for calculating the leakage flow rate between the two stationary walls was derived from the empirical study. The experimental model is simulated by computational fluid dynamics employing the ANSYS CFX commercial software in order to study the flow structure. Both numerical simulation results and empirical formula results are in good agreement with the experimental results. The correction of the empirical formula is verified by experimental data and has been proven to be very useful in terms of quickly predicting the leakage flow rate in the guide vanes for hydraulic turbines.

  17. Postoperative Cerebrospinal Fluid Leakage Associated With Total En Bloc Spondylectomy.

    PubMed

    Yokogawa, Noriaki; Murakami, Hideki; Demura, Satoru; Kato, Satoshi; Yoshioka, Katsuhito; Hayashi, Hiroyuki; Ishii, Takayoshi; Igarashi, Takashi; Fang, Xiang; Tsuchiya, Hiroyuki

    2015-07-01

    Cerebrospinal fluid (CSF) leakage is a serious postoperative complication associated with total en bloc spondylectomy. The authors examined the risk factors for CSF leakage after this procedure. A total of 72 patients underwent total en bloc spondylectomy at the authors' institution between May 2010 and April 2013. Postoperative CSF leakage was observed in 17 of the 72 patients (23.6%). The results of univariate analysis suggested that age 54 years or older, preoperative surgical site irradiation, resection of 3 or more vertebral bodies, and dural injury were significant risk factors for postoperative CSF leakage after total en bloc spondylectomy. Multivariate analysis showed that preoperative surgical site irradiation was the only significant risk factor for postoperative CSF leakage (adjusted odds ratio, 5.22; 95% confidence interval, 1.03-26.45, P=.046). The authors also assessed the course of treatment for postoperative CSF leakage in each patient. Of 17 patients with postoperative CSF leakage, 13 recovered without further complications, but 4 required reoperation (2 for wound dehiscence, 1 for surgical site infection, and 1 for severe intracranial hypotension). All 4 patients who required reoperation had a history of surgical site irradiation. Thus, this study suggests that careful consideration should be given to postoperative CSF leakage in patients with a history of surgical site irradiation. These findings may contribute to the management of postoperative CSF leakage associated with total en bloc spondylectomy and supplement the information given to the patient in the process of obtaining informed consent. PMID:26186316

  18. The Effects of Propofol on Local Field Potential Spectra, Action Potential Firing Rate, and Their Temporal Relationship in Humans and Felines

    PubMed Central

    Hanrahan, Sara J.; Greger, Bradley; Parker, Rebecca A.; Ogura, Takahiro; Obara, Shinju; Egan, Talmage D.; House, Paul A.

    2013-01-01

    Propofol is an intravenous sedative hypnotic, which, acting as a GABAA agonist, results in neocortical inhibition. While propofol has been well studied at the molecular and clinical level, less is known about the effects of propofol at the level of individual neurons and local neocortical networks. We used Utah Electrode Arrays (UEAs) to investigate the effects of propofol anesthesia on action potentials (APs) and local field potentials (LFPs). UEAs were implanted into the neocortex of two humans and three felines. The two human patients and one feline received propofol by bolus injection, while the other two felines received target-controlled infusions. We examined the changes in LFP power spectra and AP firing at different levels of anesthesia. Increased propofol concentration correlated with decreased high-frequency power in LFP spectra and decreased AP firing rates, and the generation of large-amplitude spike-like LFP activity; however, the temporal relationship between APs and LFPs remained relatively consistent at all levels of propofol. The probability that an AP would fire at this local minimum of the LFP increased with propofol administration. The propofol-induced suppression of neocortical network activity allowed LFPs to be dominated by low-frequency spike-like activity, and correlated with sedation and unconsciousness. As the low-frequency spike-like activity increased and the AP–LFP relationship became more predictable firing rate encoding capacity is impaired. This suggests a mechanism for decreased information processing in the neocortex that accounts for propofol-induced unconsciousness. PMID:23576977

  19. A harmonic pulse testing method for leakage detection in deep subsurface storage formations

    NASA Astrophysics Data System (ADS)

    Sun, Alexander Y.; Lu, Jiemin; Hovorka, Susan

    2015-06-01

    Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy-to-implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant-rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT-based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time-lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single-phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT-based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost-effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

  20. Estimating sewer leakage from continuous tracer experiments.

    PubMed

    Rieckermann, Jörg; Bares, Vojtech; Kracht, Oliver; Braun, Daniel; Gujer, Willi

    2007-05-01

    Direct measurements of sewer leakage with continuous dosing of tracers are often considered too imprecise for practical applications. However, no mathematical framework for data analysis is reported in literature. In this paper, we present an improved experimental design and data analysis procedure together with a comprehensive framework for uncertainty assessment. Test runs in a 700 m-long watertight sewer showed no significant bias and a very high precision of the methodology. The standard error in the results was assessed to 2.6% of the labeled flow with a simplified model. It could be reduced to 1.2% when a dynamic data analysis procedure was applied. The major error contribution was caused by transient transport phenomena, which suggests that careful choosing of the experimental time is more important than the choice of a very specific tracer substance. Although the method is not intended to replace traditional CCTV inspections, it can provide complementary information for rational rehabilitation planning. PMID:17363025

  1. Torque Transmission Device at Zero Leakage

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Mullen, R. L.

    2005-01-01

    In a few critical applications, mechanical transmission of power by rotation at low speed is required without leakage at an interface. Herein we examine a device that enables torque to be transmitted across a sealed environmental barrier. The barrier represents the restraint membrane through which the torque is transmitted. The power is transferred through elastic deformation of a circular tube into an elliptical cross-section. Rotation of the principle axis of the ellipse at one end results in a commensurate rotation of an elliptical cross section at the other end of the tube. This transfer requires no rigid body rotation of the tube allowing a membrane to seal one end from the other. Both computational and experimental models of the device are presented.

  2. Fluid leakage near the percolation threshold

    PubMed Central

    Dapp, Wolf B.; Müser, Martin H.

    2016-01-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again. PMID:26839261

  3. Fluid leakage near the percolation threshold

    NASA Astrophysics Data System (ADS)

    Dapp, Wolf B.; Müser, Martin H.

    2016-02-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal—applying common assumptions of elasticity, contact mechanics, and fluid dynamics—show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again.

  4. Information Leakage Analysis by Abstract Interpretation

    NASA Astrophysics Data System (ADS)

    Zanioli, Matteo; Cortesi, Agostino

    Protecting the confidentiality of information stored in a computer system or transmitted over a public network is a relevant problem in computer security. The approach of information flow analysis involves performing a static analysis of the program with the aim of proving that there will not be leaks of sensitive information. In this paper we propose a new domain that combines variable dependency analysis, based on propositional formulas, and variables' value analysis, based on polyhedra. The resulting analysis is strictly more accurate than the state of the art abstract interpretation based analyses for information leakage detection. Its modular construction allows to deal with the tradeoff between efficiency and accuracy by tuning the granularity of the abstraction and the complexity of the abstract operators.

  5. Fluid leakage near the percolation threshold.

    PubMed

    Dapp, Wolf B; Müser, Martin H

    2016-01-01

    Percolation is a concept widely used in many fields of research and refers to the propagation of substances through porous media (e.g., coffee filtering), or the behaviour of complex networks (e.g., spreading of diseases). Percolation theory asserts that most percolative processes are universal, that is, the emergent powerlaws only depend on the general, statistical features of the macroscopic system, but not on specific details of the random realisation. In contrast, our computer simulations of the leakage through a seal--applying common assumptions of elasticity, contact mechanics, and fluid dynamics--show that the critical behaviour (how the flow ceases near the sealing point) solely depends on the microscopic details of the last constriction. It appears fundamentally impossible to accurately predict from statistical properties of the surfaces alone how strongly we have to tighten a water tap to make it stop dripping and also how it starts dripping once we loosen it again. PMID:26839261

  6. Nonideal rotations in nuclear magnetic resonance: Estimation of coherence transfer leakage

    SciTech Connect

    Jerschow, Alexej

    2000-07-15

    When spherical tensors are rotated by certain angles, coherence transfer selection rules may apply. For example, a {pi} rotation cleanly inverts the coherence order. A {pi}/2 rotation of a T{sub 0}{sup 1} tensor creates only T{sub {+-}}{sub 1}{sup 1} tensors. In this work estimations are given for the coherence transfer leakage under the action of rotations with small errors in the rotation angle or axis. Although the theory is stated with particular applications to NMR (nuclear magnetic resonance) in mind it is equally applicable wherever nonideal rotations of spherical tensors are considered (e.g., quantum computing and relaxation theory). In NMR it is useful for the estimation of coherence transfer leakage, especially in pulse sequences with many n{pi} pulses. The results are also applicable to spinors and half-integer representations of the rotation group. (c) 2000 American Institute of Physics.

  7. Midcourse correction to a clinical trial when the event rate is underestimated: the Look AHEAD (Action for Health in Diabetes) Study.

    PubMed

    Brancati, Frederick L; Evans, Mary; Furberg, Curt D; Geller, Nancy; Haffner, Steven; Kahn, Steven E; Kaufmann, Peter G; Lewis, Cora E; Nathan, David M; Pitt, Bertram; Safford, Monika M

    2012-02-01

    The Look AHEAD (Action for Health in Diabetes) Study is a long-term clinical trial that aims to determine the cardiovascular disease (CVD) benefits of an intensive lifestyle intervention (ILI) in obese adults with type 2 diabetes. The study was designed to have 90% statistical power to detect an 18% reduction in the CVD event rate in the ILI Group compared to the Diabetes Support and Education (DSE) Group over 10.5 years of follow-up. The original power calculations were based on an expected CVD rate of 3.125% per year in the DSE group; however, a much lower-than-expected rate in the first 2 years of follow-up prompted the Data and Safety Monitoring Board (DSMB) to recommend that the Steering Committee undertake a formal blinded evaluation of these design considerations. The Steering Committee created an Endpoint Working Group (EPWG) that consisted of individuals masked to study data to examine relevant issues. The EPWG considered two primary options: (1) expanding the definition of the primary endpoint and (2) extending follow-up of participants. Ultimately, the EPWG recommended that the Look AHEAD Steering Committee approve both strategies. The DSMB accepted these modifications, rather than recommending that the trial continue with inadequate statistical power. Trialists sometimes need to modify endpoints after launch. This decision should be well justified and should be made by individuals who are fully masked to interim results that could introduce bias. This article describes this process in the Look AHEAD study and places it in the context of recent articles on endpoint modification and recent trials that reported endpoint modification. PMID:22334468

  8. A catchment-scale groundwater model including sewer pipe leakage in an urban system

    NASA Astrophysics Data System (ADS)

    Peche, Aaron; Fuchs, Lothar; Spönemann, Peter; Graf, Thomas; Neuweiler, Insa

    2016-04-01

    Keywords: pipe leakage, urban hydrogeology, catchment scale, OpenGeoSys, HYSTEM-EXTRAN Wastewater leakage from subsurface sewer pipe defects leads to contamination of the surrounding soil and groundwater (Ellis, 2002; Wolf et al., 2004). Leakage rates at pipe defects have to be known in order to quantify contaminant input. Due to inaccessibility of subsurface pipe defects, direct (in-situ) measurements of leakage rates are tedious and associated with a high degree of uncertainty (Wolf, 2006). Proposed catchment-scale models simplify leakage rates by neglecting unsaturated zone flow or by reducing spatial dimensions (Karpf & Krebs, 2013, Boukhemacha et al., 2015). In the present study, we present a physically based 3-dimensional numerical model incorporating flow in the pipe network, in the saturated zone and in the unsaturated zone to quantify leakage rates on the catchment scale. The model consists of the pipe network flow model HYSTEM-EXTAN (itwh, 2002), which is coupled to the subsurface flow model OpenGeoSys (Kolditz et al., 2012). We also present the newly developed coupling scheme between the two flow models. Leakage functions specific to a pipe defect are derived from simulations of pipe leakage using spatially refined grids around pipe defects. In order to minimize computational effort, these leakage functions are built into the presented numerical model using unrefined grids around pipe defects. The resulting coupled model is capable of efficiently simulating spatially distributed pipe leakage coupled with subsurficial water flow in a 3-dimensional environment. References: Boukhemacha, M. A., Gogu, C. R., Serpescu, I., Gaitanaru, D., & Bica, I. (2015). A hydrogeological conceptual approach to study urban groundwater flow in Bucharest city, Romania. Hydrogeology Journal, 23(3), 437-450. doi:10.1007/s10040-014-1220-3. Ellis, J. B., & Revitt, D. M. (2002). Sewer losses and interactions with groundwater quality. Water Science and Technology, 45(3), 195

  9. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... adjacent cargo tanks empty and at atmospheric pressure. Each closure, except pressure relief devices and... 49 Transportation 3 2012-10-01 2012-10-01 false Pressure and leakage tests. 178.345-13 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a)...

  10. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... adjacent cargo tanks empty and at atmospheric pressure. Each closure, except pressure relief devices and... 49 Transportation 3 2011-10-01 2011-10-01 false Pressure and leakage tests. 178.345-13 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a)...

  11. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... adjacent cargo tanks empty and at atmospheric pressure. Each closure, except pressure relief devices and... 49 Transportation 3 2013-10-01 2013-10-01 false Pressure and leakage tests. 178.345-13 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a)...

  12. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... adjacent cargo tanks empty and at atmospheric pressure. Each closure, except pressure relief devices and... 49 Transportation 3 2014-10-01 2014-10-01 false Pressure and leakage tests. 178.345-13 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and leakage tests. (a)...

  13. A CONCEPTUAL UNDERSTANDING OF LEAKAGE DURING SOIL-GAS SAMPLING

    EPA Science Inventory

    A heuristic model is developed to develop a conceptual understanding of leakage during soil-gas sampling. Leakage is shown to be simply a function of the permeability contrast between the formation and borehole and geometric factors. As the ratio of formation to borehole permea...

  14. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Pressure and leakage test. 178.348-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  15. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Pressure and leakage test. 178.347-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  16. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pressure and leakage test. 178.347-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  17. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Pressure and leakage test. 178.348-5 Section 178... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b)...

  18. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... is equipped with vapor recovery equipment may be leakage tested in accordance with 40 CFR 63.425(e). To satisfy the leakage test requirements of this paragraph, the test specified in 40 CFR 63.425(e)(1) must be conducted using air. The hydrostatic test alternative permitted under Appendix A to 40 CFR...

  19. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... is equipped with vapor recovery equipment may be leakage tested in accordance with 40 CFR 63.425(e). To satisfy the leakage test requirements of this paragraph, the test specified in 40 CFR 63.425(e)(1) must be conducted using air. The hydrostatic test alternative permitted under Appendix A to 40 CFR...

  20. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Pressure and leakage test. 178.347-5 Section 178... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b)...

  1. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Pressure and leakage test. 178.347-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  2. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... is equipped with vapor recovery equipment may be leakage tested in accordance with 40 CFR 63.425(e). To satisfy the leakage test requirements of this paragraph, the test specified in 40 CFR 63.425(e)(1) must be conducted using air. The hydrostatic test alternative permitted under Appendix A to 40 CFR...

  3. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Pressure and leakage test. 178.348-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  4. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... is equipped with vapor recovery equipment may be leakage tested in accordance with 40 CFR 63.425(e). To satisfy the leakage test requirements of this paragraph, the test specified in 40 CFR 63.425(e)(1) must be conducted using air. The hydrostatic test alternative permitted under Appendix A to 40 CFR...

  5. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Pressure and leakage test. 178.348-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  6. 49 CFR 178.348-5 - Pressure and leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Pressure and leakage test. 178.348-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.348-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  7. 49 CFR 178.347-5 - Pressure and leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Pressure and leakage test. 178.347-5 Section 178... Specifications for Containers for Motor Vehicle Transportation § 178.347-5 Pressure and leakage test. (a) Each cargo tank must be tested in accordance with § 178.345-13 and this section. (b) Pressure test....

  8. 42 CFR 84.158 - Exhalation valve leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Exhalation valve leakage test. 84.158 Section 84... Respirators § 84.158 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be... between the valve and valve seat shall not exceed 30 milliliters per minute....

  9. 42 CFR 84.158 - Exhalation valve leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Exhalation valve leakage test. 84.158 Section 84... Respirators § 84.158 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be... between the valve and valve seat shall not exceed 30 milliliters per minute....

  10. 42 CFR 84.158 - Exhalation valve leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Exhalation valve leakage test. 84.158 Section 84... Respirators § 84.158 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be... between the valve and valve seat shall not exceed 30 milliliters per minute....

  11. 42 CFR 84.158 - Exhalation valve leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test. 84.158 Section 84.158 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Supplied-Air Respirators § 84.158 Exhalation valve leakage...

  12. 42 CFR 84.158 - Exhalation valve leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test. 84.158 Section 84... Respirators § 84.158 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be subjected to a suction of 25 mm. water-column height while in a normal operating position. (b)...

  13. 75 FR 29699 - Total Inward Leakage Requirements for Respirators

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-27

    ... Inward Leakage Requirements for Respirators on Friday, October 30, 2009 (74 FR 56141). NIOSH held a... Federal Register on Friday, October 30, 2009 (74 FR 56141). The purpose of the meeting is to allow... process in the area of filtering facepiece or other half-mask respirator inward leakage measurement,...

  14. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY....123 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be subjected to...

  15. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY....123 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be subjected to...

  16. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY....123 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be subjected to...

  17. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY....123 Exhalation valve leakage test. (a) Dry exhalation valves and valve seats will be subjected to...

  18. Key Molecular Mechanisms of Chaiqinchengqi Decoction in Alleviating the Pulmonary Albumin Leakage Caused by Endotoxemia in Severe Acute Pancreatitis Rats.

    PubMed

    Wu, Wei; Luo, Ruijie; Lin, Ziqi; Xia, Qing; Xue, Ping

    2016-01-01

    To reveal the key molecular mechanisms of Chaiqinchengqi decoction (CQCQD) in alleviating the pulmonary albumin leakage caused by endotoxemia in severe acute pancreatitis (SAP) rats. Rats models of SAP endotoxemia-induced acute lung injury were established, the studies in vivo provided the important evidences that the therapy of CQCQD significantly ameliorated the increases in plasma levels of lipopolysaccharide (LPS), sCd14, and Lbp, the elevation of serum amylase level, the enhancements of systemic and pulmonary albumin leakage, and the depravation of airways indicators, thus improving respiratory dysfunction and also pancreatic and pulmonary histopathological changes. According to the analyses of rats pulmonary tissue microarray and protein-protein interaction network, c-Fos, c-Src, and p85α were predicted as the target proteins for CQCQD in alleviating pulmonary albumin leakage. To confirm these predictions, human umbilical vein endothelial cells were employed in in vitro studies, which provide the evidences that (1) LPS-induced paracellular leakage and proinflammatory cytokines release were suppressed by pretreatment with inhibitors of c-Src (PP1) or PI3K (LY294002) or by transfection with siRNAs of c-Fos; (2) fortunately, CQCQD imitated the actions of these selective inhibitions agents to inhibit LPS-induced high expressions of p-Src, p-p85α, and c-Fos, therefore attenuating paracellular leakage and proinflammatory cytokines release. PMID:27413385

  19. Key Molecular Mechanisms of Chaiqinchengqi Decoction in Alleviating the Pulmonary Albumin Leakage Caused by Endotoxemia in Severe Acute Pancreatitis Rats

    PubMed Central

    Wu, Wei; Luo, Ruijie; Lin, Ziqi; Xia, Qing

    2016-01-01

    To reveal the key molecular mechanisms of Chaiqinchengqi decoction (CQCQD) in alleviating the pulmonary albumin leakage caused by endotoxemia in severe acute pancreatitis (SAP) rats. Rats models of SAP endotoxemia-induced acute lung injury were established, the studies in vivo provided the important evidences that the therapy of CQCQD significantly ameliorated the increases in plasma levels of lipopolysaccharide (LPS), sCd14, and Lbp, the elevation of serum amylase level, the enhancements of systemic and pulmonary albumin leakage, and the depravation of airways indicators, thus improving respiratory dysfunction and also pancreatic and pulmonary histopathological changes. According to the analyses of rats pulmonary tissue microarray and protein-protein interaction network, c-Fos, c-Src, and p85α were predicted as the target proteins for CQCQD in alleviating pulmonary albumin leakage. To confirm these predictions, human umbilical vein endothelial cells were employed in in vitro studies, which provide the evidences that (1) LPS-induced paracellular leakage and proinflammatory cytokines release were suppressed by pretreatment with inhibitors of c-Src (PP1) or PI3K (LY294002) or by transfection with siRNAs of c-Fos; (2) fortunately, CQCQD imitated the actions of these selective inhibitions agents to inhibit LPS-induced high expressions of p-Src, p-p85α, and c-Fos, therefore attenuating paracellular leakage and proinflammatory cytokines release. PMID:27413385

  20. Leakage performance of the GM + CCL liner system for the MSW landfill.

    PubMed

    Jingjing, Fan

    2014-01-01

    The contaminants in the landfill leachate press pose a grave threat to environment of the soil and the groundwater beneath the landfill. Despite there being strict requirements in relevant provisions of both domestic and foreign countries for the design of the bottom liner system. Pollution of the soil and the groundwater still took place in a number of landfills because of the leakage. To investigate the leakage rate of the liner systems, the minimum design requirements of the liner systems are summarized according to the provisions of four countries, including China, USA, Germany, and Japan. Comparative analyses using one-dimensional transport model are conducted to study the leakage performance of these liner systems composed of geomembrance (GM) and compacted clay layer (CCL) meeting the relevant minimum design requirements. Then parametric analyses are conducted to study the effects of the hydraulic head, the thickness of GM, the hydraulic conductivity of CCL, and so forth on the leakage performance of the liner system. It is concluded that the liner system designed according to the minimum design requirements of Germany provide the best antileakage performance, while that of Japan performs the lowest. The key parameters affecting the failure time of the liner system are summarized. Finally, some suggestions for the design of the liner systems are made according to the analyses. PMID:24719569

  1. Leakage Performance of the GM + CCL Liner System for the MSW Landfill

    PubMed Central

    Jingjing, Fan

    2014-01-01

    The contaminants in the landfill leachate press pose a grave threat to environment of the soil and the groundwater beneath the landfill. Despite there being strict requirements in relevant provisions of both domestic and foreign countries for the design of the bottom liner system. Pollution of the soil and the groundwater still took place in a number of landfills because of the leakage. To investigate the leakage rate of the liner systems, the minimum design requirements of the liner systems are summarized according to the provisions of four countries, including China, USA, Germany, and Japan. Comparative analyses using one-dimensional transport model are conducted to study the leakage performance of these liner systems composed of geomembrance (GM) and compacted clay layer (CCL) meeting the relevant minimum design requirements. Then parametric analyses are conducted to study the effects of the hydraulic head, the thickness of GM, the hydraulic conductivity of CCL, and so forth on the leakage performance of the liner system. It is concluded that the liner system designed according to the minimum design requirements of Germany provide the best antileakage performance, while that of Japan performs the lowest. The key parameters affecting the failure time of the liner system are summarized. Finally, some suggestions for the design of the liner systems are made according to the analyses. PMID:24719569

  2. Geochemical Implications of Gas Leakage Associated with Geologic CO2 Storage - A Qualitative Review

    SciTech Connect

    Harvey, Omar R.; Qafoku, Nikolla; Cantrell, Kirk J.; Lee, Gie Hyeon; Amonette, James E.; Brown, Christopher F.

    2013-01-01

    Leakage from deep storage reservoirs is considered the major risk factor associated with geologic sequestration of CO2. Different schools of thought exist concerning the potential implications of such leakage for near-surface environments. We reviewed the current literature on how CO2 leakage (from storage reservoirs) would likely impact the geochemistry of overlying potable aquifers. Results from experimental and modeling studies point to the potential for both beneficial (e.g. contaminant immobilization) and deleterious (e.g. contaminant mobilization) consequences of CO2 intrusion into potable groundwater. However, there are significant discrepancies between studies particularly concerning, what contaminants are of concern and the geochemical processes involved. These discrepancies reflected the lack of a consensus on CO2-induced changes in subsurface geochemical processes and subsequent effects on groundwater chemistry. The development of consistent experimental protocols and the identification of pertinent factors driving CO2-induced geochemical changes in the subsurface were identified as key research needs. Geochemical modeling was used to systematically highlight why a standardization of experimental protocols and the consideration of experimental factors such as gas leakage rates, redox status and the influence of co-transported gases are pertinent. The role of analog studies, reactions occurring in the vadose zone, and the influence of organic contaminants are also discussed.

  3. Comparing Natural Gas Leakage Detection Technologies Using an Open-Source "Virtual Gas Field" Simulator.

    PubMed

    Kemp, Chandler E; Ravikumar, Arvind P; Brandt, Adam R

    2016-04-19

    We present a tool for modeling the performance of methane leak detection and repair programs that can be used to evaluate the effectiveness of detection technologies and proposed mitigation policies. The tool uses a two-state Markov model to simulate the evolution of methane leakage from an artificial natural gas field. Leaks are created stochastically, drawing from the current understanding of the frequency and size distributions at production facilities. Various leak detection and repair programs can be simulated to determine the rate at which each would identify and repair leaks. Integrating the methane leakage over time enables a meaningful comparison between technologies, using both economic and environmental metrics. We simulate four existing or proposed detection technologies: flame ionization detection, manual infrared camera, automated infrared drone, and distributed detectors. Comparing these four technologies, we found that over 80% of simulated leakage could be mitigated with a positive net present value, although the maximum benefit is realized by selectively targeting larger leaks. Our results show that low-cost leak detection programs can rely on high-cost technology, as long as it is applied in a way that allows for rapid detection of large leaks. Any strategy to reduce leakage should require a careful consideration of the differences between low-cost technologies and low-cost programs. PMID:27007771

  4. Esophagojejunal anastomosis leakage after total gastrectomy for esophagogastric junction adenocarcinoma: options of treatment

    PubMed Central

    Valle, Mario; Federici, Orietta; Levi Sandri, Giovanni Battista; Camperchioli, Ida; Lapenta, Rocco; Assisi, Daniela; Garofalo, Alfredo

    2016-01-01

    Background Esophagojejunal anastomosis leakage after total gastrectomy (TG) for esophagogastric junction (EGJ) adenocarcinoma (ADC) constitutes one of the most serious and sometimes life-threatening complications. Management remains controversial and still challenging. Methods A total of 198 patients operated for type I and II EGJ ADC were reviewed. Diagnosis of leakage was based on a combination of clinical and radiological findings. It was classified including objective endoscopic and clinical parameters requiring different type of treatment. Results Anastomotic leakage was diagnosed in 14 patients (7%). Two cases recovered with conservative therapy. Six cases underwent endoscopy with clips placement in 2 and partially covered self-expandable metal stent placement in 4. Other two cases underwent reoperation with reconstruction of anastomosis and primary repair respectively. In the last four cases emergency surgery with total esophagectomy and diversion was required. Mortality occurred only in 3 of these patients and overall treatment was successful in 11 patients (78.5%). Conclusions No consensus has been reached on the best method of esophagojejunal anastomosis leakage management and the rate of failure remains significant. Different options of treatment are available but early detection and multidisciplinary approaches are the keys to obtain successful results irrespective of the employed strategy. PMID:27563440

  5. Suppressing leakage by localized doping in Si nanotransistor channels.

    PubMed

    Maassen, Jesse; Guo, Hong

    2012-12-28

    By first principles atomistic analysis we demonstrate how controlled localized doping distributions in nanoscale Si transistors can suppress leakage currents. We consider dopants (B and P atoms) to be randomly confined to a ≈1  nm width doping region in the channel. If this region is located away from the electrodes, roughly 20% of the channel length L, the tunneling leakage is reduced 2× compared to the case of uniform doping and shows little variation. Oppositely, we find the leakage current increases by orders of magnitude and may result in large device variability. We calculate the maximum and minimum conductance ratio that characterizes the tunnel leakage for various values of L. We conclude that doping engineering provides a possible approach to resolve the critical issue of leakage current in nanotransistors. PMID:23368599

  6. Technology Solutions Case Study: Predicting Envelope Leakage in Attached Dwellings

    SciTech Connect

    2013-11-01

    The most common method of measuring air leakage is to perform single (or solo) blower door pressurization and/or depressurization test. In detached housing, the single blower door test measures leakage to the outside. In attached housing, however, this “solo” test method measures both air leakage to the outside and air leakage between adjacent units through common surfaces. In an attempt to create a simplified tool for predicting leakage to the outside, Building America team Consortium for Advanced Residential Buildings (CARB) performed a preliminary statistical analysis on blower door test results from 112 attached dwelling units in four apartment complexes. Although the subject data set is limited in size and variety, the preliminary analyses suggest significant predictors are present and support the development of a predictive model. Further data collection is underway to create a more robust prediction tool for use across different construction types, climate zones, and unit configurations.

  7. Simulation of permeability evolution of leakage pathway in carbonate-rich caprocks in carbon sequestration

    NASA Astrophysics Data System (ADS)

    Guo, B.; Fitts, J. P.; Dobossy, M. E.; Peters, C. A.

    2013-12-01

    Geologic carbon sequestration in deep saline aquifers is a promising strategy for mitigating climate change. A major concern is the possibility of brine and CO2 migration through the caprock such as through fractures and faults. In this work, we examine the extent to which mineral dissolution will substantially alter the porosity and permeability of caprock leakage pathways as CO2-acidified brine flows through them. Three models were developed. Firstly, a reactive transport model, Permeability Evolution of Leakage pathway (PEL), was developed to simulate permeability evolution of a leakage pathway during the injection period, and assumes calcite is the only reactive mineral. The system domain is a 100 m long by 0.2 m diameter cylindrical flow path with fixed boundaries containing a rock matrix with an initial porosity of 30% and initial permeability of 1×10-13 m2. One example result is for an initial calcite volume fraction (CVF) of 0.20, in which all the calcite is dissolved after 50 years and the permeability reaches 3.2×10-13 m2. For smaller values of CVF, the permeability reaches its final value earlier but the increase in permeability is minimal. For a large value of CVF such as 0.50, the permeability could eventually reach 1×10-12 m2, but the large amount of dissolved calcium buffers the solution and slows the reaction. After 50 years the permeability change is negligible. Thus, there is a non-monotonic relationship between the amount of calcite in the rock and the resulting permeability change because of the competing dynamics of calcite dissolution and alkalinity build-up. In the second model, PEL was coupled to an existing basin-scale multiphase flow model, Princeton's Estimating Leakage Semi-Analytical (ELSA) model. The new model, ELSA-PEL, estimates the brine and CO2 leakage rates during the injection period under conditions of permeability evolution. The scenario considered in this work is for 50 years of CO2 injection into the Mt. Simon formation in

  8. Postoperative non-steroidal anti-inflammatory drugs and colorectal anastomotic leakage. NSAIDs and anastomotic leakage.

    PubMed

    Klein, Mads

    2012-03-01

    Anastomotic leakage (AL) is the most important and one of the most serious complications after colorectal resections with primary anastomosis. Any factors that contribute to increase the risk of AL should be identified and--if possible--eliminated. Non-steroidal anti-inflammatory drugs (NSAIDs) are often used for treating pain after surgical procedures, among these also colorectal resections. The objective of this Ph.d. thesis was to investigate whether the use of NSAIDs in the postoperative period increases the risk of AL, and investigate the effect on pathophysiological mechanisms. In order to achieve this, the following studies were performed. Study I was a retrospective, case-control study in 75 patients undergoing laparoscopic colorectal resection for colorectal cancer. 33 of these patients received the NSAID diclofenac in the postoperative period; the remaining 42 did not receive any NSAID. There were significantly more ALs among the patients receiving diclofenac (7/33 vs. 1/42, p=0.018). In uni- and multivariate logistic regression analyses, diclofenac was the only factor associated with increased AL rate. This study functioned as a hypothesis generating study and laid the ground for the subsequent studies. Study II was an experimental, randomized, case-control study in 32 Wistar rats. The rats had a colonic anastomosis performed and were randomized to diclofenac or placebo treatment. After three days, the rats were sacrificed and the anastomoses were harvested. First, the anastomotic strengths were tested by longitudinal; subsequently, the levels of the enzyme cyclooxygenase-2 (COX-2) in the anastomotic tissues were measured. There was no difference among the groups with regard to anastomotic strength, but the animals treated with diclofenac had significantly lower COX-2 levels (median (range) 1.30 (0.42-3.31) ng/mg vs. 2.44 (0.88 - 18.94) ng/mg, p<0.001). This study showed that the used dose of diclofenac was sufficient and relevant, but did not show a

  9. Atmospheric leakage and condensate production in NASA's biomass production chamber. Effect of diurnal temperature cycles

    NASA Technical Reports Server (NTRS)

    Wheeler, Raymond M.; Drese, John H.; Sager, John C.

    1991-01-01

    A series of tests were conducted to monitor atmospheric leakage rate and condensate production in NASA's Biomass Production Chamber (BPC). Water was circulated through the 64 plant culture trays inside the chamber during the tests but no plants were present. Environmental conditions were set to a 12-hr photoperiod with either a matching 26 C (light)/20 C (dark) thermoperiod, or a constant 23 C temperature. Leakage, as determined by carbon dioxide decay rates, averaged about 9.8 percent for the 26 C/20 C regime and 7.3 percent for the constant 23 C regime. Increasing the temperature from 20 C to 26 C caused a temporary increase in pressure (up to 0.5 kPa) relative to ambient, while decreasing the temperature caused a temporary decrease in pressure of similar magnitude. Little pressure change was observed during transition between 23 C (light) and 23 C (dark). The lack of large pressure events under isothermal conditions may explain the lower leakage rate observed. When only the plant support inserts were placed in the culture trays, condensate production averaged about 37 liters per day. Placing acrylic germination covers over the tops of culture trays reduced condensate production to about 7 liters per day. During both tests, condensate production from the lower air handling system was 60 to 70 percent greater than from the upper system, suggesting imbalances exist in chilled and hot water flows for the two air handling systems. Results indicate that atmospheric leakage rates are sufficiently low to measure CO2 exchange rates by plants and the accumulation of certain volatile contaminants (e.g., ethylene). Control system changes are recommended in order to balance operational differences (e.g., humidity and temperature) between the two halves of the chamber.

  10. Actionable Nuggets

    PubMed Central

    McColl, Mary Ann; Aiken, Alice; Smith, Karen; McColl, Alexander; Green, Michael; Godwin, Marshall; Birtwhistle, Richard; Norman, Kathleen; Brankston, Gabrielle; Schaub, Michael

    2015-01-01

    Abstract Objective To present the results of a pilot study of an innovative methodology for translating best evidence about spinal cord injury (SCI) for family practice. Design Review of Canadian and international peer-reviewed literature to develop SCI Actionable Nuggets, and a mixed qualitative-quantitative evaluation to determine Nuggets’ effect on physician knowledge of and attitudes toward patients with SCI, as well as practice accessibility. Setting Ontario, Newfoundland, and Australia. Participants Forty-nine primary care physicians. Methods Twenty Actionable Nuggets (pertaining to key health issues associated with long-term SCI) were developed. Nugget postcards were mailed weekly for 20 weeks to participating physicians. Prior knowledge of SCI was self-rated by participants; they also completed an online posttest to assess the information they gained from the Nugget postcards. Participants’ opinions about practice accessibility and accommodations for patients with SCI, as well as the acceptability and usefulness of Nuggets, were assessed in interviews. Main findings With Actionable Nuggets, participants’ knowledge of the health needs of patients with SCI improved, as knowledge increased from a self-rating of fair (58%) to very good (75%) based on posttest quiz results. The mean overall score for accessibility and accommodations in physicians’ practices was 72%. Participants’ awareness of the need for screening and disease prevention among this population also increased. The usefulness and acceptability of SCI Nugget postcards were rated as excellent. Conclusion Actionable Nuggets are a knowledge translation tool designed to provide family physicians with concise, practical information about the most prevalent and pressing primary care needs of patients with SCI. This evidence-based resource has been shown to be an excellent fit with information consumption processes in primary care. They were updated and adapted for distribution by the Canadian

  11. The effect of inhalation resistance on facepiece leakage.

    PubMed

    Nelson, T J; Colton, C E

    2000-01-01

    Air purifying respirators use filters to remove particulate air contaminants. Resistance to airflow generally increases as the filter loads and a "filter cake" is formed. It has been recommended by ANSI and the Occupational Safety and Health Administration that filters should be replaced when the wearer notices they are hard to breathe through. Repeated faceseal leak rate measurements were made during respiratory wear over a range of simulated breathing resistances from 5.6 to 19.6 mm (0.22 to 0.77 inches) of water. The measured faceseal leak rates increased as the breathing resistance increased and varied depending on the initial leak rate at the 5.6 mm pressure. The increase in faceseal leak rate from 5.6 to 19.6 mm breathing resistance was as high as a factor of 4. Theoretically, a person with an initial respirator penetration of 2.5% could have that value increase to 10% as filter loading increased breathing resistance by 14 mm. Some research has shown that breathing resistances between 60 and 140 mm of water would be "noticeable but well tolerated." It is not known if workers would be able to detect an increase in breathing resistance that would lead to a significant increase in faceseal leakage. These data suggest a need to establish a replacement schedule for all filters used in the workplace. How often a filter should be replaced is difficult to determine. Breathing resistance would vary depending on the individual filter and aerosol loading characteristics, the concentration of the aerosol in the workplace, and breathing rates. PMID:10772622

  12. Mode of action of metabolites from Bacillus sp. strain IBA 33 on Geotrichum citri-aurantii arthroconidia.

    PubMed

    Gordillo, María Antonieta; Navarro, Antonio R; Maldonado, María Cristina

    2015-11-01

    Geotrichum citri-aurantii is a postharvest phytopathogenic fungus of lemons. We studied the mode of action of antifungal metabolites from Bacillus sp. strain IBA 33 on arthroconidia of G. citri-aurantii. These metabolites are lipopeptides belonging to the iturin family. Membrane permeabilization of G. citri-aurantii was analyzed and mitochondrial respiratory rate was evaluated. Disturbance of the plasma membrane promotes the leakage of many cellular components into the surrounding media, and mitochondrial membrane disorganization promotes the inhibition of the respiratory rate. Our findings provide insights into the ability of lipopeptides to suppress plant fungal pathogens and their possible agronomical applications. PMID:26394707

  13. Eddy covariance mapping and quantification of surface CO2 leakage fluxes

    SciTech Connect

    Lewicki, J.L.; Hilley, G.E.

    2009-08-01

    We present eddy covariance measurements of net CO{sub 2} flux (F{sub c}) made during a controlled release of CO{sub 2} (0.3 t d{sup -1} from 9 July to 7 August 2008) from a horizontal well {approx}100 m in length and {approx}2.5 m in depth located in an agricultural field in Bozeman, MT. We isolated fluxes arising from the release (F{sub cr}) by subtracting fluxes corresponding to a model for net ecosystem exchange from F{sub c}. A least-squares inversion of 611 F{sub cr} and corresponding modeled footprint functions recovered the location, length, and magnitude of the surface CO{sub 2} flux leakage signal, although high wavenumber details of the signal were poorly resolved. The estimated total surface CO{sub 2} leakage rate (0.32 t d{sup ?1}) was within 7% of the release rate.

  14. thin films toward less leakage currents

    NASA Astrophysics Data System (ADS)

    Yao, Zhao; Wang, Cong; Li, Yang; Kim, Hong-Ki; Kim, Nam-Young

    2014-08-01

    To prepare high-density integrated capacitors with low leakage currents, 0.2-μm-thick BaTiO3 thin films were successfully deposited on integrated semiconductor substrates at room temperature by the aerosol deposition (AD) method. In this study, the effects of starting powder size were considered in an effort to remove macroscopic defects. A surface morphology of 25.3 nm and an interface roughness of less than 50 nm were obtained using BT-03B starting powder. The nano-crystalline thin films achieved after deposition were annealed at various temperatures to promote crystallization and densification. Moreover, the influence of rapid thermal annealing process on the surface morphology and crystal growth was evaluated. As the annealing temperature increased from room temperature to 650°C, the root mean square (RMS) roughness decreased from 25.3 to 14.3 nm. However, the surface was transformed into rough performance at 750°C, which agreed well with the surface microstructure trend. Moreover, the crystal growth also reveals the changes in surface morphology via surface energy analysis.

  15. Quantum Speed Limits for Leakage and Decoherence

    NASA Astrophysics Data System (ADS)

    Marvian, Iman; Lidar, Daniel A.

    2015-11-01

    We introduce state-independent, nonperturbative Hamiltonian quantum speed limits for population leakage and fidelity loss, for a gapped open system interacting with a reservoir. These results hold in the presence of initial correlations between the system and the reservoir, under the sole assumption that their interaction and its commutator with the reservoir Hamiltonian are norm bounded. The reservoir need not be thermal and can be time dependent. We study the significance of energy mismatch between the system and the local degrees of freedom of the reservoir that directly interact with the system. We demonstrate that, in general, by increasing the system gap we may reduce this energy mismatch, and, consequently, drive the system and the reservoir into resonance; this can accelerate fidelity loss, irrespective of the thermal properties or state of the reservoir. This implies that quantum error suppression strategies based on increasing the gap are not uniformly beneficial. Our speed limits also yield an elementary lower bound on the relaxation time of spin systems.

  16. Quantum Speed Limits for Leakage and Decoherence.

    PubMed

    Marvian, Iman; Lidar, Daniel A

    2015-11-20

    We introduce state-independent, nonperturbative Hamiltonian quantum speed limits for population leakage and fidelity loss, for a gapped open system interacting with a reservoir. These results hold in the presence of initial correlations between the system and the reservoir, under the sole assumption that their interaction and its commutator with the reservoir Hamiltonian are norm bounded. The reservoir need not be thermal and can be time dependent. We study the significance of energy mismatch between the system and the local degrees of freedom of the reservoir that directly interact with the system. We demonstrate that, in general, by increasing the system gap we may reduce this energy mismatch, and, consequently, drive the system and the reservoir into resonance; this can accelerate fidelity loss, irrespective of the thermal properties or state of the reservoir. This implies that quantum error suppression strategies based on increasing the gap are not uniformly beneficial. Our speed limits also yield an elementary lower bound on the relaxation time of spin systems. PMID:26636833

  17. Thermal image analysis for detecting facemask leakage

    NASA Astrophysics Data System (ADS)

    Dowdall, Jonathan B.; Pavlidis, Ioannis T.; Levine, James

    2005-03-01

    Due to the modern advent of near ubiquitous accessibility to rapid international transportation the epidemiologic trends of highly communicable diseases can be devastating. With the recent emergence of diseases matching this pattern, such as Severe Acute Respiratory Syndrome (SARS), an area of overt concern has been the transmission of infection through respiratory droplets. Approved facemasks are typically effective physical barriers for preventing the spread of viruses through droplets, but breaches in a mask"s integrity can lead to an elevated risk of exposure and subsequent infection. Quality control mechanisms in place during the manufacturing process insure that masks are defect free when leaving the factory, but there remains little to detect damage caused by transportation or during usage. A system that could monitor masks in real-time while they were in use would facilitate a more secure environment for treatment and screening. To fulfill this necessity, we have devised a touchless method to detect mask breaches in real-time by utilizing the emissive properties of the mask in the thermal infrared spectrum. Specifically, we use a specialized thermal imaging system to detect minute air leakage in masks based on the principles of heat transfer and thermodynamics. The advantage of this passive modality is that thermal imaging does not require contact with the subject and can provide instant visualization and analysis. These capabilities can prove invaluable for protecting personnel in scenarios with elevated levels of transmission risk such as hospital clinics, border check points, and airports.

  18. Combined actions of multiple hairpin loop structures and sites of rate-limiting endonucleolytic cleavage determine differential degradation rates of individual segments within polycistronic puf operon mRNA.

    PubMed Central

    Klug, G; Cohen, S N

    1990-01-01

    Differential expression of the genes within the puf operon of Rhodobacter capsulatus is accomplished in part by differences in the rate of degradation of different segments of the puf transcript. We report here that decay of puf mRNA sequences specifying the light-harvesting I (LHI) and reaction center (RC) photosynthetic membrane peptides is initiated endoribonucleolytically within a discrete 1.4-kilobase segment of the RC-coding region. Deletion of this segment increased the half-life of the RC-coding region from 8 to 20 min while not affecting decay of LHI-coding sequences upstream from an intercistronic hairpin loop structure shown previously to impede 3'-to-5' degradation. Prolongation of RC segment half-life was dependent on the presence of other hairpin structures 3' to the RC region. Inserting the endonuclease-sensitive sites into the LHI-coding segment markedly accelerated its degradation. Our results suggest that differential degradation of the RC- and LHI-coding segments of puf mRNA is accomplished at least in part by the combined actions of RC region-specific endonuclease(s), one or more exonucleases, and several strategically located exonuclease-impeding hairpins. Images PMID:2394682

  19. Effect of Viscosity on Fuel Leakage Between Lapped Plungers and Sleeves and on the Discharge from a Pump-Injection System

    NASA Technical Reports Server (NTRS)

    Rothrock, A M; Marsh, E T

    1935-01-01

    Test data and analysis show that the rate of fuel leakage between a lapped plunger and sleeve varies directly with the density of the fuel, the diameter of the plunger, the pressure producing the leakage, and the cube of the mean clearance between the plunger and sleeve. The rate varies inversely as the length of the lapped fit and the viscosity of the fuel. With a mean clearance between the plunger and sleeve of 0.0001 inch the leakage amounts to approximately 0.2 percent of the fuel injected with gasoline and as low as 0.01 percent with diesel fuel oils. With this mean clearance an effective seal is obtained when the length of the lap is three times the diameter of the lap. The deformation of the sleeve and plunger under pressure is sufficient to change the rate of leakage appreciably from that which would be obtained if the clearance was constant under pressure.

  20. Tropical nature reserves are losing their buffer zones, but leakage is not to blame.

    PubMed

    Lui, Gillian V; Coomes, David A

    2016-05-01

    Tropical forests provide important ecosystem services to humanity, yet are threatened by habitat loss resulting from deforestation and land-use change. Although reserves are considered the cornerstones of conservation efforts in the tropics, their efficacy remains equivocal. One question that remains unresolved is whether leakage - the unanticipated displacement of deforestation from inside reserves into the unrestricted zones just beyond a reserve's administrative boundary - is common around tropical forest reserves, or whether the zones are acting as buffers between the protected area and the outside world. To resolve this question, we used the Landsat-derived Global Forest Change dataset to estimate deforestation rates between 2000 and 2012 inside and outside of 60 nature reserves spread across the tropics. Deforestation rates inside reserves (within 5km of the administrative boundary) were generally lower than those immediately outside the reserves (i.e. in buffer zones 0-10km from the boundary), suggesting that reserves are effective at protecting forests. We hypothesised that leakage would result in greater deforestation rates in reserve buffer zones than in the broader reserve landscapes, but such a pattern was observed in only five African sites, suggesting that leakage does not often occur on the edge of established reserves. However, roughly 80% of reserves experienced deforestation rates that increased gradually from their interiors to the outer periphery of their buffer zones. Thus, while leakage may not be a pervasive phenomenon around tropical reserves worldwide, tropical reserves are often losing their buffer zones, resulting in increased isolation that could have ramifications for ecosystem services provisioning and tropical conservation strategies. PMID:26632993

  1. Quantifying the leakage of quantum protocols for classical two-party cryptography

    NASA Astrophysics Data System (ADS)

    Salvail, Louis; Schaffner, Christian; Sotáková, Miroslava

    2015-12-01

    We study quantum protocols among two distrustful parties. By adopting a rather strict definition of correctness — guaranteeing that honest players obtain their correct outcomes only — we can show that every strictly correct quantum protocol implementing a non-trivial classical primitive necessarily leaks information to a dishonest player. This extends known impossibility results to all non-trivial primitives. We provide a framework for quantifying this leakage and argue that leakage is a good measure for the privacy provided to the players by a given protocol. Our framework also covers the case where the two players are helped by a trusted third party. We show that despite the help of a trusted third party, the players cannot amplify the cryptographic power of any primitive. All our results hold even against quantum honest-but-curious adversaries who honestly follow the protocol but purify their actions and apply a different measurement at the end of the protocol. As concrete examples, we establish lower bounds on the leakage of standard universal two-party primitives such as oblivious transfer.

  2. Quantifying the leakage of quantum protocols for classical two-party cryptography

    NASA Astrophysics Data System (ADS)

    Salvail, Louis; Schaffner, Christian; Sotáková, Miroslava

    2014-12-01

    We study quantum protocols among two distrustful parties. By adopting a rather strict definition of correctness — guaranteeing that honest players obtain their correct outcomes only — we can show that every strictly correct quantum protocol implementing a non-trivial classical primitive necessarily leaks information to a dishonest player. This extends known impossibility results to all non-trivial primitives. We provide a framework for quantifying this leakage and argue that leakage is a good measure for the privacy provided to the players by a given protocol. Our framework also covers the case where the two players are helped by a trusted third party. We show that despite the help of a trusted third party, the players cannot amplify the cryptographic power of any primitive. All our results hold even against quantum honest-but-curious adversaries who honestly follow the protocol but purify their actions and apply a different measurement at the end of the protocol. As concrete examples, we establish lower bounds on the leakage of standard universal two-party primitives such as oblivious transfer.

  3. Uncertainty Quantification and Risk Mitigation of CO2 Leakage in Groundwater Aquifers

    NASA Astrophysics Data System (ADS)

    Sun, Y.; Tong, C.; Mansoor, K.; Carroll, S.

    2013-12-01

    The risk of CO2 leakage into shallow aquifers through various pathways such as faults and abandoned wells is a concern of CO2 geological sequestration. If a leak is detected in an aquifer system, a contingency plan is required to manage the CO2 storage and to protect the groundwater source. Among many remediation and mitigation strategies, the simplest is to stop CO2 leakage at a wellbore. Therefore, it is necessary to address whether and when the CO2 leaks should be sealed, and how much risk can be mitigated. In the presence of various uncertainties, including geological-structure uncertainty and parametric uncertainty, the risk of CO2 leakage into an aquifer needs to be assessed with probabilistic distributions of uncertain parameters. In this study, we developed an integrated model to simulate multiphase flow of CO2 and brine in a deep storage reservoir, through a leaky well at an uncertain location, and subsequently multicomponent reactive transport in a shallow aquifer. Each sub-model covers its domain-specific physics. Uncertainties of geological structure and parameters are considered together with decision variables (CO2 injection rate and mitigation time) for risk assessment of leakage-impacted aquifer volume. High-resolution and less-expensive reduced-order models (ROMs) of risk profiles are approximated as polynomial functions of decision variables and all uncertain parameters. These reduced-order models are then used in the place of computationally-expensive numerical models for future decision-making on if and when the leaky well is sealed. The tradeoff between CO2 storage capacity in the reservoir and the leakage-induced risk in the aquifer is evaluated. This work performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.

  4. [Role of pelvi-perineal rehabilitation in the treatment of cavernous venous leakage].

    PubMed

    Schouman, M; Lacroix, P

    1991-01-01

    The pathophysiological mechanisms, investigation and treatment of erectile dysfunction related to venous leakage are highly controversial. Although surgery appears to be the most logical treatment, the results obtained are very uncertain, regardless of the technique, and long-term improvements are rare. In this study, the authors propose an original management based on classical pelvi-perineal rehabilitation techniques combined with low-dose intracavernous injections. The preliminary results appear encouraging with about 50% improvement (improved or cured patients) in the various treated groups with a lasting result. The mechanism of action of rehabilitation is unclear, but this non-invasive technique should be considered prior to more aggressive management. PMID:2064366

  5. Numerical simulation of tip clearance leakage vortex flow characteristic in axial flow pump

    NASA Astrophysics Data System (ADS)

    Shi, W. D.; Li, T. T.; Zhang, D. S.; Tian, F.; Zhang, G. J.

    2012-11-01

    Tip Leakage Vortex (TLV) in axial flow pump is mainly cased by the leakage flow entraining with the main stream of the blade suction side, which could interfere with the main flow field of the whole passage and the performance of pump. The low pressure area of vortex nuclear also cause the cavitation, which often induce the noise, vibration and cavitation erosion on the end wall of the impeller. The steady turbulent flow fields of the tip clearance region at different conditions with different blade tip clearance sizes (0.15 mm, 0.50 mm, 1.50 mm and 3.00mm) were simulated based on the ANSYS CFX software. The application of the different turbulent models were compared and analyzed in the whole passage flow simulation and choose a turbulent model which can adapt the tip leakage vortex flow in the axial flow pump. Furthermore, the flow fields under different tip clearance sizes were simulated, the relationship of the flow field structure and size of the tip clearance was analyzed. The numerical results show that: The SST k-ω turbulent model can predict the energy characteristics of the model pump accurately, adapt the shear flow of the adverse pressure gradient and predict the tip leakage flow very well; With the increase of the mass flow, the start position of the tip leakage vortex cores remove from near the leading edge to the trailing edge along the shroud of the blade, and the strength of the vortex cores decreased; The energy characteristic decrease with the increase of the tip clearance; The positive-slope point arrive earlier when the tip above the 1.5mm; With the increase of the tip clearance, the start position of the tip leakage vortex cores remove from near the leading edge to the trailing edge along the shroud of the blade, the pressure of the vortex cores decrease, the strength of the vortex entrainment is bigger; The leakage vortex within the tip clearance of the axial flow pump enhances as the blade tip clearance size is more than 0.50 mm, and the

  6. Duct leakage impacts on VAV system performance in California large commercial buildings

    SciTech Connect

    Wray, Craig P.; Matson, Nance E.

    2003-10-01

    The purpose of this study is to evaluate the variability of duct leakage impacts on air distribution system performance for typical large commercial buildings in California. Specifically, a hybrid DOE-2/TRNSYS sequential simulation approach was used to model the energy use of a low-pressure terminal-reheat variable-air-volume (VAV) HVAC system with six duct leakage configurations (tight to leaky) in nine prototypical large office buildings (representing three construction eras in three California climates where these types of buildings are common). Combined fan power for the variable-speed-controlled supply and return fans at design conditions was assumed to be 0.8 W/cfm. Based on our analyses of the 54 simulation cases, the increase in annual fan energy is estimated to be 40 to 50% for a system with a total leakage of 19% at design conditions compared to a tight system with 5% leakage. Annual cooling plant energy also increases by about 7 to 10%, but reheat energy decreases (about 3 to 10%). In combination, the increase in total annual HVAC site energy is 2 to 14%. The total HVAC site energy use includes supply and return fan electricity consumption, chiller and cooling tower electricity consumption, boiler electricity consumption, and boiler natural gas consumption. Using year 2000 average commercial sector energy prices for California ($0.0986/kWh and $7.71/Million Btu), the energy increases result in 9 to 18% ($7,400 to $9,500) increases in HVAC system annual operating costs. Normalized by duct surface area, the increases in annual operating costs are 0.14 to 0.18 $/ft{sup 2}. Using a suggested one-time duct sealing cost of $0.20 per square foot of duct surface area, these results indicate that sealing leaky ducts in VAV systems has a simple payback period of about 1.3 years. Even with total leakage rates as low as 10%, duct sealing is still cost effective. This suggests that duct sealing should be considered at least for VAV systems with 10% or more total duct

  7. Treatment of esophagojejunal anastomosis leakage: a systematic review from the last two decades.

    PubMed

    Aurello, Paolo; Magistri, Paolo; D'Angelo, Francesco; Valabrega, Stefano; Sirimarco, Dario; Tierno, Simone Maria; Nava, Andrea Kazemi; Ramacciato, Giovanni

    2015-05-01

    Esophagojejunal anastomosis leakage is one of the major complications after total gastrectomy for gastric cancer and is an independent predictor of survival. Our aim is to systematically review the literature and discuss the reported therapeutic approaches to identify the best therapeutic approach. Pubmed, EMbase, Cochrane Library, CILEA Archive, BMJ Clinical Evidence, and Up ToDate databases were screened limiting the research to articles written in English from January 1992 through December 2013. This way a total of 474 manuscripts were retrieved for furthermore evaluation. Eleven manuscripts were considered eligible and the study is focused on those works. We analyzed a total of 3,893 patients and 114 cases of esophagojejunal anastomosis leakage. Different treatments were grouped into three main categories: conservative approach (66 cases), endoscopic approach (21 cases), and surgical approach (27 cases). The overall mortality rate is 26.32 per cent and surgical approach showed the higher rate. According to the reported data, a complete resolution of the leakage can be achieved in an interval ranging from 7 to 28 days in the group treated conservatively. Conservative approach should always be considered as the treatment of choice. Reoperation may be necessary in case of wide dehiscence or when other treatments fail; therefore, the high mortality rate related to this procedure is due to the comorbidities of patients undergoing relaparotomy. Finally, endoscopic approach with endoclips seems promising but needs furthermore studies. PMID:25975326

  8. A quantitative methodology to assess the risks to human health from CO2 leakage into groundwater

    NASA Astrophysics Data System (ADS)

    Siirila, E.; Sitchler, A.; Maxwell, R. M.; McCray, J. E.

    2010-12-01

    suggests action levels for carcinogenic risk will be exceeded in exposure situations before noncarcinogenic action levels, a reflection of the ratio of cancer and non-cancer toxicity values. Finally, implications for ranking aquifer vulnerability due to geologic configuration, aquifer mineralogy, and leakage scenarios are discussed.

  9. Atlantic multi-decadal oscillation covaries with Agulhas leakage

    NASA Astrophysics Data System (ADS)

    Biastoch, Arne; Durgadoo, Jonathan V.; Morrison, Adele K.; van Sebille, Erik; Weijer, Wilbert; Griffies, Stephen M.

    2015-12-01

    The interoceanic transfer of seawater between the Indian Ocean and the Atlantic, `Agulhas leakage', forms a choke point for the overturning circulation in the global ocean. Here, by combining output from a series of high-resolution ocean and climate models with in situ and satellite observations, we construct a time series of Agulhas leakage for the period 1870-2014. The time series demonstrates the impact of Southern Hemisphere westerlies on decadal timescales. Agulhas leakage shows a correlation with the Atlantic Multi-decadal Oscillation on multi-decadal timescales; the former leading by 15 years. This is relevant for climate in the North Atlantic.

  10. Theory and Application of Magnetic Flux Leakage Pipeline Detection

    PubMed Central

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-01-01

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted. PMID:26690435

  11. Atlantic multi-decadal oscillation covaries with Agulhas leakage

    PubMed Central

    Biastoch, Arne; Durgadoo, Jonathan V.; Morrison, Adele K.; van Sebille, Erik; Weijer, Wilbert; Griffies, Stephen M.

    2015-01-01

    The interoceanic transfer of seawater between the Indian Ocean and the Atlantic, ‘Agulhas leakage', forms a choke point for the overturning circulation in the global ocean. Here, by combining output from a series of high-resolution ocean and climate models with in situ and satellite observations, we construct a time series of Agulhas leakage for the period 1870–2014. The time series demonstrates the impact of Southern Hemisphere westerlies on decadal timescales. Agulhas leakage shows a correlation with the Atlantic Multi-decadal Oscillation on multi-decadal timescales; the former leading by 15 years. This is relevant for climate in the North Atlantic. PMID:26656850

  12. Atlantic multi-decadal oscillation covaries with Agulhas leakage.

    PubMed

    Biastoch, Arne; Durgadoo, Jonathan V; Morrison, Adele K; van Sebille, Erik; Weijer, Wilbert; Griffies, Stephen M

    2015-01-01

    The interoceanic transfer of seawater between the Indian Ocean and the Atlantic, 'Agulhas leakage', forms a choke point for the overturning circulation in the global ocean. Here, by combining output from a series of high-resolution ocean and climate models with in situ and satellite observations, we construct a time series of Agulhas leakage for the period 1870-2014. The time series demonstrates the impact of Southern Hemisphere westerlies on decadal timescales. Agulhas leakage shows a correlation with the Atlantic Multi-decadal Oscillation on multi-decadal timescales; the former leading by 15 years. This is relevant for climate in the North Atlantic. PMID:26656850

  13. Theory and Application of Magnetic Flux Leakage Pipeline Detection.

    PubMed

    Shi, Yan; Zhang, Chao; Li, Rui; Cai, Maolin; Jia, Guanwei

    2015-01-01

    Magnetic flux leakage (MFL) detection is one of the most popular methods of pipeline inspection. It is a nondestructive testing technique which uses magnetic sensitive sensors to detect the magnetic leakage field of defects on both the internal and external surfaces of pipelines. This paper introduces the main principles, measurement and processing of MFL data. As the key point of a quantitative analysis of MFL detection, the identification of the leakage magnetic signal is also discussed. In addition, the advantages and disadvantages of different identification methods are analyzed. Then the paper briefly introduces the expert systems used. At the end of this paper, future developments in pipeline MFL detection are predicted. PMID:26690435

  14. Cerebrospinal Fluid Leakage after Thoracic Decompression

    PubMed Central

    Hu, Pan-Pan; Liu, Xiao-Guang; Yu, Miao

    2016-01-01

    Objective: The objective of this study is to review cerebrospinal fluid leakage (CSFL) after thoracic decompression and describe its regular and special features. Data Sources: Literature cited in this review was retrieved from PubMed and Medline and was primarily published during the last 10 years. “Cerebrospinal fluid”, “leakage”, “dural tears”, and “thoracic decompression” were the indexed terms. Relevant citations in the retrieved articles were also screened to include more data. Study Selection: All retrieved literature was scrutinized, and four categories were recorded: incidence and risk factors, complications, treatment modalities, and prognosis. Results: CSFL is much more frequent after thoracic decompression than after cervical and lumbar spinal surgeries. Its occurrence is related to many clinical factors, especially the presence of ossified ligaments and the adhesion of the dural sac. While its impact on the late neurological recovery is currently controversial, CSFL increases the risk of other perioperative complications, such as low intracranial pressure symptoms, infection, and vascular events. The combined use of primary repairs during the operation and conservative treatment postoperatively is generally effective for most CSFL cases, whereas lumbar drains and reoperations should be implemented as rescue options for refractory cases only. Conclusions: CSFL after thoracic decompression has not been specifically investigated, so the present study provides a systematic and comprehensive review of the issue. CSFL is a multi-factor-related complication, and pathological factors play a decisive role. The importance of CSFL is in its impact on the increased risk of other complications during the postoperative period. Methods to prevent these complications are in need. In addition, though the required treatment resources are not special for CSFL after thoracic decompression, most CSFL cases are conservatively curable, and surgeons should be

  15. Key factors for determining groundwater impacts due to leakage from geologic carbon sequestration reservoirs

    SciTech Connect

    Carroll, Susan A.; Keating, Elizabeth; Mansoor, Kayyum; Dai, Zhenxue; Sun, Yunwei; Trainor-Guitton, Whitney; Brown, Chris; Bacon, Diana

    2014-09-07

    are the most likely conduits for brine and CO2 leaks. Leakage uncertainty was based on hypothetical injection of CO2 for 50 years at a rate of 5 million tons per year into a depleted oil/gas reservoir with high permeability and, one or more wells provided leakage pathways from the storage reservoir to the overlying aquifer. This scenario corresponds to a storage site with historical oil/gas production and some poorly completed legacy wells that went undetected through site evaluation, operations, and post-closure. For the aquifer systems and leakage scenarios studied here, CO2 and brine leakage are likely to drive pH below and increase total dissolved solids (TDS) above the “no-impact thresholds;” and the subsequent plumes, although small, are likely to persist for long periods of time in the absence of remediation. In these scenarios, however, risk to human health may not be significant for two reasons. First, our simulated plume volumes are much smaller than the average inter-well spacing for these representative aquifers, so the impacted groundwater would be unlikely to be pumped for drinking water. Second, even within the impacted plume volumes little water exceeds the primary maximum contamination levels.

  16. Key factors for determining groundwater impacts due to leakage from geologic carbon sequestration reservoirs

    DOE PAGESBeta

    Carroll, Susan A.; Keating, Elizabeth; Mansoor, Kayyum; Dai, Zhenxue; Sun, Yunwei; Trainor-Guitton, Whitney; Brown, Chris; Bacon, Diana

    2014-09-07

    conduits for brine and CO2 leaks. Leakage uncertainty was based on hypothetical injection of CO2 for 50 years at a rate of 5 million tons per year into a depleted oil/gas reservoir with high permeability and, one or more wells provided leakage pathways from the storage reservoir to the overlying aquifer. This scenario corresponds to a storage site with historical oil/gas production and some poorly completed legacy wells that went undetected through site evaluation, operations, and post-closure. For the aquifer systems and leakage scenarios studied here, CO2 and brine leakage are likely to drive pH below and increase total dissolved solids (TDS) above the “no-impact thresholds;” and the subsequent plumes, although small, are likely to persist for long periods of time in the absence of remediation. In these scenarios, however, risk to human health may not be significant for two reasons. First, our simulated plume volumes are much smaller than the average inter-well spacing for these representative aquifers, so the impacted groundwater would be unlikely to be pumped for drinking water. Second, even within the impacted plume volumes little water exceeds the primary maximum contamination levels.« less

  17. Response surfaces for CO2 leakage from geologic storage along abandoned wellbores

    NASA Astrophysics Data System (ADS)

    Jordan, A.; Carey, J. W.; Pawar, R. J.; Stauffer, P. H.

    2011-12-01

    The storage of carbon dioxide (CO2) in geologic reservoirs that have previously been drilled for oil and gas exploration is under investigation worldwide as an option for reducing the amount of anthropogenic carbon introduced to the atmosphere. Reservoirs that have already been tapped for hydrocarbon production have several benefits over development of new sites: they tend to be geologically well-understood, with existing wellbore data to help further characterize the local geologic framework; are known to be conducive to trapping buoyant or pressurized fluids; may have infrastructure in place; and are likely to be already impacted ecologically as compared to pristine sites. One downside to using depleted hydrocarbon reservoirs is the potential for CO2 leakage along pre-existing wellbores that were either not designed for CO2 sequestration or have been improperly plugged and abandoned. The primary goal of this study is to develop estimates of possible wellbore leakage rates of CO2 from storage reservoirs to the surface and/or into overlaying aquifers, as a function of wellbore properties and the surrounding geologic framework. The Finite Element Heat and Mass transfer code (FEHM) was used to perform Monte Carlo simulations of multiphase flow along wellbores across a wide range of geologic and wellbore parameters. Several wellbore scenarios were studied, including a simple wellbore between the CO2 storage reservoir and the surface; a wellbore intersecting a saline aquifer ("thief zone"); and a wellbore intersecting both a thief zone and a freshwater aquifer. The Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE) software was used to analyze results and produce response surfaces for the estimation of wellbore flow rate as a function of the primary factors that influence leakage. These results will be used to develop abstractions for leakage rates to be incorporated in performance assessments of geologic CO2 storage, which will help

  18. A Semi-Analytical Solution for Large-Scale Injection-Induced PressurePerturbation and Leakage in a Laterally Bounded Aquifer-AquitardSystem

    SciTech Connect

    Zhou, Quanlin; Birkholzer, Jens T.; Tsang, Chin-Fu

    2008-07-15

    A number of (semi-)analytical solutions are available to drawdown analysis and leakage estimation of shallow aquifer-aquitard systems. These solutions assume that the systems are laterally infinite. When a large-scale pumping from (or injection into) an aquifer-aquitard system of lower specific storativity occurs, induced pressure perturbation (or hydraulic head drawdown/rise) may reach the lateral boundary of the aquifer. We developed semi-analytical solutions to address the induced pressure perturbation and vertical leakage in a 'laterally bounded' system consisting of an aquifer and an overlying/underlying aquitard. A one-dimensional radial flow equation for the aquifer was coupled with a one-dimensional vertical flow equation for the aquitard, with a no-flow condition imposed on the outer radial boundary. Analytical solutions were obtained for (1) the Laplace-transform hydraulic head drawdown/rise in the aquifer and in the aquitard, (2) the Laplace-transform rate and volume of leakage through the aquifer-aquitard interface integrated up to an arbitrary radial distance, (3) the transformed total leakage rate and volume for the entire interface, and (4) the transformed horizontal flux at any radius. The total leakage rate and volume depend only on the hydrogeologic properties and thicknesses of the aquifer and aquitard, as well as the duration of pumping or injection. It was proven that the total leakage rate and volume are independent of the aquifer's radial extent and wellbore radius. The derived analytical solutions for bounded systems are the generalized solutions of infinite systems. Laplace-transform solutions were numerically inverted to obtain the hydraulic head drawdown/rise, leakage rate, leakage volume, and horizontal flux for given hydrogeologic and geometric conditions of the aquifer-aquitard system, as well as injection/pumping scenarios. Application to a large-scale injection-and-storage problem in a bounded system was demonstrated.

  19. Cement leakage in pedicle screw augmentation: a prospective analysis of 98 patients and 474 augmented pedicle screws.

    PubMed

    Mueller, Jan U; Baldauf, Joerg; Marx, Sascha; Kirsch, Michael; Schroeder, Henry W S; Pillich, Dirk T

    2016-07-01

    OBJECTIVE Loosening and pullout of pedicle screws are well-known problems in pedicle screw fixation surgery. Augmentation of pedicle screws with bone cement, first described as early as 1975, increases the pedicle-screw interface and pullout force in osteoporotic vertebrae. The aim of the present study was to identify cement leakage and pulmonary embolism rates in a large prospective single-center series of pedicle screw augmentations. METHODS All patients who underwent cement-augmented pedicle screw placement between May 2006 and October 2010 at the authors' institution were included in this prospective cohort study. Perivertebral cement leakage and pulmonary cement embolism were evaluated with a CT scan of the area of operation and with a radiograph of the chest, respectively. RESULTS A total of 98 patients underwent placement of cement-augmented pedicle screws; 474 augmented screws were inserted in 237 vertebrae. No symptomatic perivertebral cement leakage or symptomatic pulmonary cement embolism was observed, but asymptomatic perivertebral cement leakage was seen in 88 patients (93.6%) and in 165 augmented vertebrae (73.3%). Cement leakage most often occurred in the perivertebral venous system. Clinically asymptomatic pulmonary cement embolism was found in 4 patients (4.1%). CONCLUSIONS Perivertebral cement leakage often occurs in pedicle screw augmentation, but in most cases, it is clinically asymptomatic. Cement augmentation should be performed under continuous fluoroscopy to avoid high-volume leakage. Alternative strategies, such as use of expandable screws, should be examined in more detail for patients at high risk of screw loosening. PMID:26943258

  20. Induced seismicity and CO2 leakage through fault zones during large-scale underground injection in a multilayered sedimentary system

    NASA Astrophysics Data System (ADS)

    Rinaldi, A.; Rutqvist, J.; Jeanne, P.; Cappa, F.

    2013-12-01

    The importance of geomechanics including the potential for reactivating faults associated with large-scale geologic carbon sequestration operations has recently become more widely recognized. However, not withstanding the potential for triggering notable (felt) seismic events, the potential for buoyancy-driven CO2 to reach potable groundwater and the ground surface is more important from safety and storage-efficiency perspectives. In this context, this work extends previous studies on the geomechanical modeling of fault responses during underground carbon dioxide injection, focusing on short-term integrity of the sealing caprock, and hence of potential leakage of either brine or CO2 to shallow groundwater aquifers during active injection. We account for a stress/strain-dependent permeability and study the leakage through a fault zone as its permeability changes during a reactivation, also causing seismicity. We analyze several scenarios related to the injected amount of CO2 (and hence as a function of the overpressure) both involving minor and major faults, and analyze the profile risks of leakage for different stress/strain permeability coupling functions, as well as increasing the complexity of the fault zone in terms of hydromechanical heterogeneities. We conclude that whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. The presence of hydromechanical heterogeneity influences the pressure diffusion, as well as the effective normal and shear stress evolution. Hydromechanical heterogeneities (i) strengthen the fault zone resulting in earthquake of small magnitude, and (ii) prevent a good fluid migration upward along the fault. We also study the effects of the caprock and aquifer thickness on the resulting induced seismicity and CO2 leakage, both in heterogeneous and homogeneous fault zone. Results show that a thin caprock or aquifer allows smaller events

  1. Degradation of Leakage Currents and Reliability Prediction for Tantalum Capacitors

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander

    2016-01-01

    Two types of failures in solid tantalum capacitors, catastrophic and parametric, and their mechanisms are described. Analysis of voltage and temperature reliability acceleration factors reported in literature shows a wide spread of results and requires more investigation. In this work, leakage currents in two types of chip tantalum capacitors were monitored during highly accelerated life testing (HALT) at different temperatures and voltages. Distributions of degradation rates were approximated using a general log-linear Weibull model and yielded voltage acceleration constants B = 9.8 +/- 0.5 and 5.5. The activation energies were Ea = 1.65 eV and 1.42 eV. The model allows for conservative estimations of times to failure and was validated by long-term life test data. Parametric degradation and failures are reversible and can be annealed at high temperatures. The process is attributed to migration of charged oxygen vacancies that reduce the barrier height at the MnO2/Ta2O5 interface and increase injection of electrons from the MnO2 cathode. Analysis showed that the activation energy of the vacancies' migration is 1.1 eV.

  2. LABORATORY EVALUATION OF THE DELTA Q TEST FOR DUCT LEAKAGE

    SciTech Connect

    ANDREWS,J.W.

    2003-05-01

    Using a residential-size duct system in a controlled laboratory setting, the repeatability and accuracy of the Delta Q test for air leakage in residential duct systems have been measured. More than 100 Delta Q tests were performed. These were compared with results using fan pressurization and also with results of a procedure (Delta Q Plus) that uses leakage hole-size information to select the leakage pressures to be used in the Delta Q algorithm. The average error in supply or return leakage for the fan-pressurization test was 6.4% of system fan flow. For the Delta Q test it was 3.4% of fan flow, while for Delta Q Plus it was 1.9% of fan flow.

  3. Biliary leakage after urgent cholecystectomy: Optimization of endoscopic treatment

    PubMed Central

    Ljubičić, Neven; Bišćanin, Alen; Pavić, Tajana; Nikolić, Marko; Budimir, Ivan; Mijić, August; Đuzel, Ana

    2015-01-01

    AIM: To investigate the results of endoscopic treatment of postoperative biliary leakage occurring after urgent cholecystectomy with a long-term follow-up. METHODS: This is an observational database study conducted in a tertiary care center. All consecutive patients who underwent endoscopic retrograde cholangiography (ERC) for presumed postoperative biliary leakage after urgent cholecystectomy in the period between April 2008 and April 2013 were considered for this study. Patients with bile duct transection and biliary strictures were excluded. Biliary leakage was suspected in the case of bile appearance from either percutaneous drainage of abdominal collection or abdominal drain placed at the time of cholecystectomy. Procedural and main clinical characteristics of all consecutive patients with postoperative biliary leakage after urgent cholecystectomy, such as indication for cholecystectomy, etiology and type of leakage, ERC findings and post-ERC complications, were collected from our electronic database. All patients in whom the leakage was successfully treated endoscopically were followed-up after they were discharged from the hospital and the main clinical characteristics, laboratory data and common bile duct diameter were electronically recorded. RESULTS: During a five-year period, biliary leakage was recognized in 2.2% of patients who underwent urgent cholecystectomy. The median time from cholecystectomy to ERC was 6 d (interquartile range, 4-11 d). Endoscopic interventions to manage biliary leakage included biliary stent insertion with or without biliary sphincterotomy. In 23 (77%) patients after first endoscopic treatment bile flow through existing surgical drain ceased within 11 d following biliary therapeutic endoscopy (median, 4 d; interquartile range, 2-8 d). In those patients repeat ERC was not performed and the biliary stent was removed on gastroscopy. In seven (23%) patients repeat ERC was done within one to fourth week after their first ERC

  4. The effect of base/liner use on restoration leakage.

    PubMed

    von Fraunhofer, J A; Marshall, K R; Holman, B G

    2006-01-01

    Central to the success of a restoration is the quality of the restoration-dentin interfacial seal; any compromise of the seal can lead to secondary or recurrent decay. Class V restorations have a high leakage propensity and this study evaluates the effect of base/liner placement on leakage behavior. Class V intracoronal half enamel/half dentin preparations (3.0 x 2.0 x 2.0 mm) were cut in four groups (n = 10) of extracted human teeth with a new bur used for each cavity preparation. All teeth were single-rooted, single-canal anterior teeth. Base/liner usage differed between each group. The first group of teeth had no liner or base, while a liner was placed in the second group of teeth prior to conditioning and restoration. A base was placed in the third group of cavity preparations and both the base and liner were placed in the fourth group. After preparation, a small diameter bare-end PVC-insulated copper wire was inserted within the root canal of each tooth from the apex to firm contact with the pulp chamber roof. The tooth-wire interface and root surface was sealed and leakage was followed electrochemically for 35 days in 0.9% NaCl solution. All of the teeth leaked to some degree; however, teeth that were restored without liner or base demonstrated the smallest amount of leakage. The greatest leakage was noted in teeth restored with both a base and a liner; teeth restored with only a base showed greater leakage than those restored with only a liner. The findings indicate that the presence of a base and/or a liner results in greater leakage compared with intracoronal Class V preparations that were conditioned and restored only. The data suggest that placing both a base and a liner increases restoration leakage significantly. PMID:16689065

  5. Characterizing inward leakage in a pressure-demand, self-contained breathing apparatus.

    PubMed

    Bryant, Rodney A; Mensch, Amy

    2011-07-01

    An analytical model of the flow across a resistive flow path such as an orifice or pipe was applied to predict the inward leakage in the facepiece of a self-contained breathing apparatus (SCBA) during a steady below-ambient facepiece pressure. The model was used to estimate leakage rates with respect to the size of the leak and for below-ambient (negative) pressure conditions reflective of measured occurrences. Results of the model were also used to make quantitative estimates of the protection level of the respirator. Experiments were designed to induce a continuous below-ambient pressure inside the facepiece of a pressure-demand SCBA mounted on a headform. Negative facepiece pressure measured in the presence of a leak correlated with the measured particle concentration ratio. Results show that the analytical model generated reasonable estimates of leakage rates during conditions of negative pressure inside the facepiece. Thus, the analytical model performed well for constant flow conditions, demonstrating the capability to predict a momentary compromise in respirator protection during momentary negative facepiece pressure conditions. PMID:21667373

  6. Agulhas leakage as a key process in the modes of Quaternary climate changes.

    PubMed

    Caley, Thibaut; Giraudeau, Jacques; Malaizé, Bruno; Rossignol, Linda; Pierre, Catherine

    2012-05-01

    Heat and salt transfer from the Indian Ocean to the Atlantic Ocean (Agulhas leakage) has an important effect on the global thermohaline circulation and climate. The lack of long transfer record prevents elucidation of its role on climate changes throughout the Quaternary. Here, we present a 1,350-ka accumulation rate record of the planktic foraminiferal species Globorotalia menardii. We demonstrate that, according to previous assumptions, the presence and reseeding of this fauna in the subtropical southeast Atlantic was driven by interocean exchange south of Africa. The Agulhas transfer strengthened at glacial ice-volume maxima for every glacial-interglacial transition, with maximum reinforcements organized according to a 400-ka periodicity. The long-term dynamics of Agulhas leakage may have played a crucial role in regulating meridional overturning circulation and global climate changes during the Mid-Brunhes event and the Mid-Pleistocene transition, and could also play an important role in the near future. PMID:22508999

  7. Acute Alcohol Intoxication-Induced Microvascular Leakage

    PubMed Central

    Doggett, Travis M.; Breslin, Jerome W.

    2014-01-01

    Background Alcohol intoxication can increase inflammation and worsen injury, yet the mechanisms involved are not clear. We investigated whether acute alcohol intoxication elevates microvascular permeability, and investigated potential signaling mechanisms in endothelial cells that may be involved. Methods Conscious rats received a 2.5 g/kg alcohol bolus via gastric catheters to produce acute intoxication. Microvascular leakage of intravenously administered FITC-albumin from the mesenteric microcirculation was assessed by intravital microscopy. Endothelial-specific mechanisms were studied using cultured endothelial cell monolayers. Transendothelial electrical resistance (TER) served as an index of barrier function, before and after treatment with alcohol or its metabolite acetaldehyde. Pharmacologic agents were used to test the roles of alcohol metabolism, oxidative stress, p38 mitogen-activated protein (MAP) kinase, myosin light chain kinase (MLCK), rho kinase (ROCK), and exchange protein activated by cAMP (Epac). VE-cadherin localization was investigated to assess junctional integrity. Rac1 and RhoA activation were assessed by ELISA assays. Results Alcohol significantly increased FITC-albumin extravasation from the mesenteric microcirculation. Alcohol also significantly decreased TER and disrupted VE-cadherin organization at junctions. Acetaldehyde significantly decreased TER, but inhibition of ADH or application of a superoxide dismutase mimetic failed to prevent alcohol-induced decreases in TER. Inhibition of p38 MAP kinase, but not MLCK or ROCK, significantly attenuated the alcohol-induced barrier dysfunction. Alcohol rapidly decreased GTP-bound Rac1 but not RhoA during the drop in TER. Activation of Epac increased TER, but did not prevent alcohol from decreasing TER. However, activation of Epac after initiation of alcohol-induced barrier dysfunction quickly resolved TER to baseline levels. Conclusions Our results suggest that alcohol intoxication increases

  8. Development and Application of the Reactor Coolant On-Line Leakage Evaluation Model for Pressurized Water Reactors

    SciTech Connect

    Liang, Thomas K.S.; Hung, H.-J.; Chang, C.-J.

    2001-12-15

    With the consideration of mass unbalance, coolant shrinking, and compressibility, a model for reactor coolant leakage evaluation has been developed to quantify on-line the system leakage rate with conventional system measurements, regardless of where the leak occurs. This model has been derived from the system of total continuity, and it divides the reactor coolant system (RCS) into two regions, namely, the saturated and subcooled regions. The pressurizer is considered as a saturated region, and the remaining part of the RCS is regarded as a subcooled region. Taking the on-line measurements of the RCS including the RCS pressure, temperature, pressurizer water level, and charging and letdown flow rates, this model can directly evaluate on-line the RCS leakage rate. It is noted that this model is applicable only if the RCS remains subcooled. To verify the applicability of this model, data generated by RELAP5/MOD3 simulation and experimental measurements from the Institute of Nuclear Energy Research, Taiwan, Integral System Test Facility were adopted to assess this model. With further on-line verification against the Maanshan training simulator, this model was finally delivered to the Maanshan nuclear power plant (a three-looped Westinghouse pressurized water reactor) to assist the operator training and on-line evaluation of the RCS leakage rate. The smallest amount of leak flow that can be detected by the ROCK model is 3 gal/min.

  9. Field size dependent mapping of medical linear accelerator radiation leakage

    NASA Astrophysics Data System (ADS)

    Vũ Bezin, Jérémi; Veres, Attila; Lefkopoulos, Dimitri; Chavaudra, Jean; Deutsch, Eric; de Vathaire, Florent; Diallo, Ibrahima

    2015-03-01

    The purpose of this study was to investigate the suitability of a graphics library based model for the assessment of linear accelerator radiation leakage. Transmission through the shielding elements was evaluated using the build-up factor corrected exponential attenuation law and the contribution from the electron guide was estimated using the approximation of a linear isotropic radioactive source. Model parameters were estimated by a fitting series of thermoluminescent dosimeter leakage measurements, achieved up to 100 cm from the beam central axis along three directions. The distribution of leakage data at the patient plane reflected the architecture of the shielding elements. Thus, the maximum leakage dose was found under the collimator when only one jaw shielded the primary beam and was about 0.08% of the dose at isocentre. Overall, we observe that the main contributor to leakage dose according to our model was the electron beam guide. Concerning the discrepancies between the measurements used to calibrate the model and the calculations from the model, the average difference was about 7%. Finally, graphics library modelling is a readily and suitable way to estimate leakage dose distribution on a personal computer. Such data could be useful for dosimetric evaluations in late effect studies.

  10. Energy Efficient High-Pressure Turbine Leakage Technology Report

    NASA Technical Reports Server (NTRS)

    Gardner, W. B.

    1980-01-01

    The leakage test program was one of such supporting technology programs structured to provide guidance to the Energy Efficient Engine High Pressure Turbine Component Design Effort. Leakage reduction techniques were identified and evaluated. Test models were used to simulate component leak paths and to evaluate leakage reduction techniques. These models simulated the blade/disk attachment, the vane inner platform attachment, and the vane outer platform attachment combined with the blade outer airseal. Disk blade attachment testing indicated that leakage in this area could be reduced to very low levels by paying careful attention to the tolerances along the contact surface between the blade vibration damper and the blade platform contact surface. The aim of feather seal testing was to achieve a goal for an effective leakage gap of one mil (.001 inch) per inch of feather seal length. Results indicated that effective gaps even below the goal level were achievable by (1) maintaining close tolerances between feather seals and their slots to minimize end gaps and limit seal rotation, (2) avoiding feather seal overlap, and (3) minimizing feather seal intersections. W seals were shown to be effective leakage control devices. Wire rope, in its present state of development, was shown not to be an effective sealing concept for application to the component design.

  11. INDEP approach for leakage reduction in nanoscale CMOS circuits

    NASA Astrophysics Data System (ADS)

    Sharma, Vijay Kumar; Pattanaik, Manisha; Raj, Balwinder

    2015-02-01

    Complementary metal oxide semiconductor (CMOS) technology scaling for improving speed and functionality turns leakage power one of the major concerns for nanoscale circuits design. The minimization of leakage power is a rising challenge for the design of the existing and future nanoscale CMOS circuits. This paper presents a novel, input-dependent, transistor-level, low leakage and reliable INput DEPendent (INDEP) approach for nanoscale CMOS circuits. INDEP approach is based on Boolean logic calculations for the input signals of the extra inserted transistors within the logic circuit. The gate terminals of extra inserted transistors depend on the primary input combinations of the logic circuits. The appropriate selection of input gate voltages of INDEP transistors are reducing the leakage current efficiently along with rail to rail output voltage swing. The important characteristic of INDEP approach is that it works well in both active as well as standby modes of the circuits. This approach overcomes the limitations created by the prevalent current leakage reduction techniques. The simulation results indicate that INDEP approach mitigates 41.6% and 35% leakage power for 1-bit full adder and ISCAS-85 c17 benchmark circuit, respectively, at 32 nm bulk CMOS technology node.

  12. LASER APPLICATIONS AND OTHER TOPICS IN QUANTUM ELECTRONICS: Remote laser detection of natural gas leakages from pipelines

    NASA Astrophysics Data System (ADS)

    Petukhov, V. O.; Gorobets, V. A.; Andreev, Yu M.; Lanskii, G. V.

    2010-02-01

    A differential absorption lidar based on a tunable TEA CO2 laser emitting at 42 lines of the 'hot' 0111 — 1110 band in the range from 10.9 to 11.4 μm is developed for detecting natural gas leakages from oil pipelines by measuring the ethane content in the atmosphere. The ethane detection sensitivity is 0.9 ppm km. The presence of methane does not distort the measurement results. The developed lidar can detect the natural gas leakage from kilometre heights at the flying velocities up to 200 km h-1 and a probe pulse repetition rate of 5 Hz.

  13. Repair and prevention of cerebrospinal fluid leakage in transsphenoidal surgery: a sphenoid sinus mucosa technique.

    PubMed

    Amano, Kosaku; Hori, Tomokatsu; Kawamata, Takakazu; Okada, Yoshikazu

    2016-01-01

    Cerebrospinal fluid (CSF) leakage is a common but sometimes serious complication after transsphenoidal surgery (TSS). To avoid this postsurgical complication, we usually repair the CSF leaking area using an autologous material, such as fat, fascia, or muscle graft and sometimes nasonasal septal flap. In this report, we propose a technique using a novel autologous material, sphenoid sinus mucosa (SSM), to repair intraoperative CSF leakage or prevent it postoperatively. On 26 February 2007, we introduced the technique of using SSM to repair or prevent CSF leakage in TSS. Until 30th of June 2014, we performed 500 TSSs for patients with pituitary or parasellar lesions. They were 195 men and 305 women with a mean age of 48.5 years (range, 5-85 years). We used SSM for patching or suturing the arachnoid laceration or dural defect, in lieu of fat or fascia harvested from abdomen or thigh, or made pedicle flap of SSM instead of nasonasal septal flap to cover the sellar floor. Comparing the previous 539 cases not using these techniques before 26 February 2007, intraoperative CSF leakage increased from 49 to 69.4% (p < 0.0001) due to more aggressive surgical technique, mainly related to more extensive approaches and lesion removals, but the rate of using fat was reduced significantly from 35.5 to 19.4% (p = 0.00021) in small or moderate CSF leaks during TSS without increasing the reoperation rate for postoperative CSF leaks (1.86 vs 1.2%, p = 0.45). The technique of using SSM to repair intraoperative CSF leaks or prevent them postoperatively in TSS was considered useful, effective, less invasive, easier for graft harvesting (same surgical field), and providing natural anatomical reconstruction, without potential donor site morbidity. We can recommend it as a standard method for CSF leaks repair and prevention in TSS. PMID:26338198

  14. Integrated Framework for Assessing Impacts of CO₂ Leakage on Groundwater Quality and Monitoring-Network Efficiency: Case Study at a CO₂ Enhanced Oil Recovery Site.

    PubMed

    Yang, Changbing; Hovorka, Susan D; Treviño, Ramón H; Delgado-Alonso, Jesus

    2015-07-21

    This study presents a combined use of site characterization, laboratory experiments, single-well push-pull tests (PPTs), and reactive transport modeling to assess potential impacts of CO2 leakage on groundwater quality and leakage-detection ability of a groundwater monitoring network (GMN) in a potable aquifer at a CO2 enhanced oil recovery (CO2 EOR) site. Site characterization indicates that failures of plugged and abandoned wells are possible CO2 leakage pathways. Groundwater chemistry in the shallow aquifer is dominated mainly by silicate mineral weathering, and no CO2 leakage signals have been detected in the shallow aquifer. Results of the laboratory experiments and the field test show no obvious damage to groundwater chemistry should CO2 leakage occur and further were confirmed with a regional-scale reactive transport model (RSRTM) that was built upon the batch experiments and validated with the single-well PPT. Results of the RSRTM indicate that dissolved CO2 as an indicator for CO2 leakage detection works better than dissolved inorganic carbon, pH, and alkalinity at the CO2 EOR site. The detection ability of a GMN was assessed with monitoring efficiency, depending on various factors, including the natural hydraulic gradient, the leakage rate, the number of monitoring wells, the aquifer heterogeneity, and the time for a CO2 plume traveling to the monitoring well. PMID:26052928

  15. Direct Measurement of Pore Dynamics and Leakage Induced by a Model Antimicrobial Peptide in Single Vesicles and Cells.

    PubMed

    Burton, Matthew G; Huang, Qi M; Hossain, Mohammed A; Wade, John D; Palombo, Enzo A; Gee, Michelle L; Clayton, Andrew H A

    2016-06-28

    Antimicrobial peptides are promising therapeutic alternatives to counter growing antimicrobial resistance. Their precise mechanism of action remains elusive, however, particularly with respect to live bacterial cells. We investigated the interaction of a fluorescent melittin analogue with single giant unilamellar vesicles, giant multilamellar vesicles, and bilamellar Gram-negative Escherichia coli (E. coli) bacteria. Time-lapse fluorescence lifetime imaging microscopy was employed to determine the population distribution of the fluorescent melittin analogue between pore state and membrane surface state, and simultaneously measure the leakage of entrapped fluorescent species from the vesicle (or bacterium) interior. In giant unilamellar vesicles, leakage from vesicle interior was correlated with an increase in level of pore states, consistent with a stable pore formation mechanism. In giant multilamellar vesicles, vesicle leakage occurred more gradually and did not appear to correlate with increased pore states. Instead pore levels remained at a low steady-state level, which is more in line with coupled equilibria. Finally, in single bacterial cells, significant increases in pore levels were observed over time, which were correlated with only partial loss of cytosolic contents. These observations suggested that pore formation, as opposed to complete dissolution of membrane, was responsible for the leakage of contents in these systems, and that the bacterial membrane has an adaptive capacity that resists peptide attack. We interpret the three distinct pore dynamics regimes in the context of the increasing physical and biological complexity of the membranes. PMID:27281288

  16. Air-leakage effects on stone cladding panels

    NASA Astrophysics Data System (ADS)

    Colantonio, Antonio

    1995-03-01

    This paper looks at the effects of air leakage on insulated stone clad precast panels used in present day construction of large commercial buildings. The building investigated was a newly built twenty story office building in a high density urban setting. Air leakage was suspected as a possible cause for thermal comfort complaints at isolated locations within the perimeter zones of the building. During the warrantee period the building owner asked for a quality control inspection of the air barrier assembly of the building envelope. Infrared thermography was used to locate areas of suspected air leakage within the building envelope. In order to differentiate thermal patterns produced by air leakage, conduction and convection as well as radiation from external sources, the building was inspected from the exterior; (1) after being pressurized for three hours, (2) one hour after the building was depressurized and (3) two and a half hours after total building depressurization was maintained by the building mechanical systems. Thermal images from similar locations were correlated for each time and pressure setting to verify air leakage locations within the building envelope. Areas exhibiting air leakage were identified and contractors were requested to carry out the necessary repairs. The pressure differential across the building envelope needs to be known in order to properly carry out an inspection to identify all locations of air leakage within a building envelope. As well the direction of the air movement and the density of the cladding material need to be accounted for in the proper inspection of these types of wall assemblies.

  17. Midcourse correction to a clinical trial when the event rate is underestimated: The Look AHEAD (Action of health in diabetes) study

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The Look AHEAD (Action for Health in Diabetes) Study is a long-term clinical trial that aims to determine the cardiovascular disease (CVD) benefits of an intensive lifestyle intervention (ILI) in obese adults with type 2 diabetes. The study was designed to have 90% statistical power to detect an 18%...

  18. Measured river leakages using conventional streamflow techniques: The case of Souhegan River, New Hampshire, USA

    USGS Publications Warehouse

    Harte, P.T.; Kiah, R.G.

    2009-01-01

    Multiple streamflow measurements were made at coupled discharge measurement stations to quantify rates of aquifer recharge and discharge on two reaches of the Souhegan River, New Hampshire, USA, flowing within a glacial-drift river-valley aquifer. The reaches included a predominantly losing (aquifer recharge) reach and a variable (aquifer recharge and discharge) reach located downstream of the former reach. River leakage, the differential between coupled upstream and downstream streamflow measurements along a reach, varied by almost 30 cubic feet per second (ft3/s) (0.85 m3/s) along the two reaches. The upper reach averaged 3.94 ft3/s (0.11 m3/s) loss whereas the lower reach averaged 4.85 ft3/s (0.14 m3/s) gain. At the upper reach, 13 losses were measured out of 19 coupled measurements. At the lower reach, ten out of 13 coupled measurements indicated gains in flow and suggest that this reach is primarily a gaining river reach. An important factor in river leakage appears to be antecedent trends in river stage. At the upper reach, gains were measured only during periods of declining river stage. Conversely, at the lower reach, streamflow loss was measured primarily during periods of rising river stage. Although some tendencies exist, several factors complicate the analysis of river leakage, most notably the inaccuracies in computed stream discharge. ?? Springer-Verlag 2008.

  19. Geochemical Implications of CO2 Leakage Associated with Geologic Storage: A Review

    SciTech Connect

    Harvey, Omar R.; Qafoku, Nikolla; Cantrell, Kirk J.; Brown, Christopher F.

    2012-07-09

    Leakage from deep storage reservoirs is a major risk factor associated with geologic sequestration of carbon dioxide (CO2). Different scientific theories exist concerning the potential implications of such leakage for near-surface environments. The authors of this report reviewed the current literature on how CO2 leakage (from storage reservoirs) would likely impact the geochemistry of near surface environments such as potable water aquifers and the vadose zone. Experimental and modeling studies highlighted the potential for both beneficial (e.g., CO2 re sequestration or contaminant immobilization) and deleterious (e.g., contaminant mobilization) consequences of CO2 intrusion in these systems. Current knowledge gaps, including the role of CO2-induced changes in redox conditions, the influence of CO2 influx rate, gas composition, organic matter content and microorganisms are discussed in terms of their potential influence on pertinent geochemical processes and the potential for beneficial or deleterious outcomes. Geochemical modeling was used to systematically highlight why closing these knowledge gaps are pivotal. A framework for studying and assessing consequences associated with each factor is also presented in Section 5.6.

  20. An experimental investigation on the tip leakage noise in axial-flow fans with rotating shroud

    NASA Astrophysics Data System (ADS)

    Canepa, Edward; Cattanei, Andrea; Mazzocut Zecchin, Fabio; Milanese, Gabriele; Parodi, Davide

    2016-08-01

    The tip leakage noise generated by a shrouded rotor of an axial-flow fan has been experimentally studied. The measurements have been taken at high flow rate and at the design point in a hemi-anechoic chamber, at constant rotational speed and during speed ramps. A test plenum designed according to ISO 10302 has been employed to modify the operating conditions and different inlet configurations, ducted and unducted with standard and reduced tip gap, have been considered. The basic features of the inflow have been studied by means of aerodynamic measurements taken upstream of the rotor. To separate the noise generating mechanisms from the acoustic propagation effects, the acoustic response function of the test configuration has been computed employing the spectral decomposition method, and then it has been compared with the velocity-scaled, constant-Strouhal number SPL. In this way, the noise components related to the tip leakage flow have been identified and their connection with geometry have been highlighted. The broadband part of the spectra and the peaks related to the tip leakage flow are affected by the same propagation effects, but show a different dependence on the rotational speed and on the operating point. The upstream geometry affects the radiated noise much more than the performance and even a strong reduction in the tip-gap cannot completely eliminate the related noise.

  1. Percutaneous Extraction of Cement Leakage After Vertebroplasty Under CT and Fluoroscopy Guidance: A New Technique

    SciTech Connect

    Amoretti, Nicolas Huwart, Laurent

    2012-12-15

    Purpose: We report a new minimally invasive technique of extraction of cement leakage following percutaneous vertebroplasty in adults. Methods: Seven adult patients (five women, two men; mean age: 81 years) treated for vertebral compression fractures by percutaneous vertebroplasty had cement leakage into perivertebral soft tissues along the needle route. Immediately after vertebroplasty, the procedure of extraction was performed under computed tomography (CT) and fluoroscopy guidance: a Chiba needle was first inserted using the same route as the vertebroplasty until contact was obtained with the cement fragment. This needle was then used as a guide for an 11-gauge Trocar t'am (Thiebaud, France). After needle withdrawal, a 13-gauge endoscopy clamp was inserted through the cannula to extract the cement fragments. The whole procedure was performed under local anesthesia. Results: In each patient, all cement fragments were withdrawn within 10 min, without complication. Conclusions: This report suggests that this CT- and fluoroscopy-guided percutaneous technique of extraction could reduce the rate of cement leakage-related complications.

  2. Eccentricity effects on leakage of a brush seal at low speeds

    NASA Technical Reports Server (NTRS)

    Schlumberger, Julie A.; Proctor, Margaret P.; Hendricks, Robert C.

    1991-01-01

    The effects of eccentricity on brush seal leakage at low rotational speeds were investigated. Included are the leakage results for ambient temperature air and nearly saturated streams at three different rotor eccentricities at both 0 and 400 rpm. A brush seal with a nominal bore diameter of 13.647 cm. (5.3730 in.) was used. It had a radial concentric interference of 0.071 cm (0.0028 in.) and a fence height of 0.0927 cm (0.0365 in.). There were 1060 bristles per centimeter of circumference (2690 bristles per inch of circumference). Rotor eccentricities of 0.003, 0.010, 0.038, and 0.043 cm (0.001, 0.004, 0.015, and 0.017 in.) were achieved by using bushings with different offsets. The results were compared with an annular seal model (FLOWCAL) for air and to a standard labyrinth seal model for steam. The annular seal model was also compared with a bulk flow model of a concentric brush seal in air. Large eccentricities did not damage the brush seals or their Haynes 25 bristles. However, the 304 stainless steel rotor did not show wear, indicating a harder surface is needed. Only the stream data showed hysteresis and were affected by shaft rotation. The brush seal had lower leakage rates than those predicted for comparable annular and labyrinth seals (conventional) because of the large clearances those seals require to accommodate large shaft excursions.

  3. Degradation of Leakage Currents in Solid Tantalum Capacitors Under Steady-State Bias Conditions

    NASA Technical Reports Server (NTRS)

    Teverovsky, Alexander A.

    2010-01-01

    Degradation of leakage currents in various types of solid tantalum capacitors under steady-state bias conditions was investigated at temperatures from 105 oC to 170 oC and voltages up to two times the rated voltage. Variations of leakage currents with time under highly accelerated life testing (HALT) and annealing, thermally stimulated depolarization currents, and I-V characteristics were measured to understand the conduction mechanism and the reason for current degradation. During HALT the currents increase gradually up to three orders of magnitude in some cases, and then stabilize with time. This degradation is reversible and annealing can restore the initial levels of leakage currents. The results are attributed to migration of positively charged oxygen vacancies in tantalum pentoxide films that diminish the Schottky barrier at the MnO2/Ta2O5 interface and increase electron injection. A simple model allows for estimation of concentration and mobility of oxygen vacancies based on the level of current degradation.

  4. Measured river leakages using conventional streamflow techniques: the case of Souhegan River, New Hampshire, USA

    NASA Astrophysics Data System (ADS)

    Harte, Philip T.; Kiah, Richard G.

    2009-03-01

    Multiple streamflow measurements were made at coupled discharge measurement stations to quantify rates of aquifer recharge and discharge on two reaches of the Souhegan River, New Hampshire, USA, flowing within a glacial-drift river-valley aquifer. The reaches included a predominantly losing (aquifer recharge) reach and a variable (aquifer recharge and discharge) reach located downstream of the former reach. River leakage, the differential between coupled upstream and downstream streamflow measurements along a reach, varied by almost 30 cubic feet per second (ft3/s) (0.85 m3/s) along the two reaches. The upper reach averaged 3.94 ft3/s (0.11 m3/s) loss whereas the lower reach averaged 4.85 ft3/s (0.14 m3/s) gain. At the upper reach, 13 losses were measured out of 19 coupled measurements. At the lower reach, ten out of 13 coupled measurements indicated gains in flow and suggest that this reach is primarily a gaining river reach. An important factor in river leakage appears to be antecedent trends in river stage. At the upper reach, gains were measured only during periods of declining river stage. Conversely, at the lower reach, streamflow loss was measured primarily during periods of rising river stage. Although some tendencies exist, several factors complicate the analysis of river leakage, most notably the inaccuracies in computed stream discharge.

  5. Suppression and control of leakage field in electromagnetic helical microwiggler

    SciTech Connect

    Ohigashi, N.; Tsunawaki, Y.; Imasaki, K.

    1995-12-31

    Shortening the period of electromagnetic wiggler introduces both the radical increase of the leakage field and the decrease of the field in the gap region. The leakage field is severer problem in planar electromagnetic wiggler than in helical wiggler. Hence, in order to develop a short period electromagnetic wiggler, we have adopted {open_quotes}three poles per period{close_quotes} type electromagnetic helical microwiggler. In this work, we inserted the permanent magnet (PM) blocks with specific magnetized directions in the space between magnetic poles, for suppressing the leakage field flowing out from a pole face to the neighboring pole face. These PM-blocks must have higher intrinsic coersive force than saturation field of pole material. The gap field due to each pole is adjustable by controlling the leakage fields, that is, controlling the position of each iron screw set in each retainer fixing the PM-blocks. At present time, a test wiggler with period 7.8mm, periodical number 10 and gap length 4.6mm has been manufactured. Because the ratio of PM-block aperture to gap length is important parameter to suppress the leakage field, the parameter has been surveyed experimentally for PM-blocks with several dimensions of aperture. The field strength of 3-5kG (K=0.2-0.4) would be expected in the wiggler.

  6. The Leakage Risk Monetization Model for Geologic CO2 Storage.

    PubMed

    Bielicki, Jeffrey M; Pollak, Melisa F; Deng, Hang; Wilson, Elizabeth J; Fitts, Jeffrey P; Peters, Catherine A

    2016-05-17

    We developed the Leakage Risk Monetization Model (LRiMM) which integrates simulation of CO2 leakage from geologic CO2 storage reservoirs with estimation of monetized leakage risk (MLR). Using geospatial data, LRiMM quantifies financial responsibility if leaked CO2 or brine interferes with subsurface resources, and estimates the MLR reduction achievable by remediating leaks. We demonstrate LRiMM with simulations of 30 years of injection into the Mt. Simon sandstone at two locations that differ primarily in their proximity to existing wells that could be leakage pathways. The peak MLR for the site nearest the leakage pathways ($7.5/tCO2) was 190x larger than for the farther injection site, illustrating how careful siting would minimize MLR in heavily used sedimentary basins. Our MLR projections are at least an order of magnitude below overall CO2 storage costs at well-sited locations, but some stakeholders may incur substantial costs. Reliable methods to detect and remediate leaks could further minimize MLR. For both sites, the risk of CO2 migrating to potable aquifers or reaching the atmosphere was negligible due to secondary trapping, whereby multiple impervious sedimentary layers trap CO2 that has leaked through the primary seal of the storage formation. PMID:27052112

  7. Radio frequency leakage current from unipolar laparoscopic electrocoagulators.

    PubMed

    DiNovo, J A

    1983-09-01

    Radio frequency (RF) leakage current has been suspected of causing accidental tissue burns associated with laparoscopic electrocoagulation used for tubal sterilization. A study was done to determine the levels of capacitively coupled RF leakage current from six unipolar laparoscopes manufactured by five companies. Leakage current values ranging from less than 100 mA to over 550 mA were measured at electrosurgical unit power settings of up to 150 w into 1,000 ohms. These levels represent 24-62% of the total electrosurgical current generated by the electrosurgical units. Using a criterion for tissue injury of 100 mA/sq cm applied for ten seconds, leakage current levels exceeding 400 mA are capable of producing burns either at the abdominal wall or to internal organs that accidentally come into contact with the body of the laparoscope. One of the six devices tested had leakage current levels higher than 400 mA at power settings lower than 100 w. Capacitance measurements between the unipolar laparoscope body and the forceps ranged from 53 to 140 picofarads. PMID:6226780

  8. Percutaneous Management of Postoperative Duodenal Stump Leakage with Foley Catheter

    SciTech Connect

    Oh, Jung Suk Lee, Hae Giu Chun, Ho Jong; Choi, Byung Gil; Lee, Sang Hoon; Hahn, Seong Tai; Ohm, Joon Young

    2013-10-15

    Purpose: This study was designed to evaluate retrospectively the safety and efficacy of the percutaneous management of duodenal stump leakage with a Foley catheter after subtotal gastrectomy. Methods: Ten consecutive patients (M:F = 9:1, median age: 64 years) were included in this retrospective study. The duodenal stump leakages were diagnosed in all the patients within a median of 10 days (range, 6-20). At first, the patients underwent percutaneous drainage on the day of or the day after confirmation of the presence of duodenal stump leakage, and then the Foley catheters were replaced at a median of 9 days (range, 6-38) after the percutaneous drainage. Results: Foley catheters were placed successfully in the duodenal lumen of all the patients under a fluoroscopic guide. No complication was observed during and after the procedures in all the patients. All of the patients started a regular diet 1 day after the Foley catheter placement. The patients were discharged at a median of 7 days (range, 5-14) after the Foley catheter placement. The catheters were removed in an outpatient clinic 10-58 days (median, 28) after the Foley catheter placement. Conclusions: Fluoroscopy-guided percutaneous Foley catheter placement may be a safe and effective treatment option for postoperative duodenal stump leakage and may allow for shorter hospital stays, earlier oral intake, and more effective control of leakage sites.

  9. Controlling leakage losses in subwavelength grating silicon metamaterial waveguides.

    PubMed

    Sarmiento-Merenguel, J Darío; Ortega-Moñux, Alejandro; Fédéli, Jean-Marc; Wangüemert-Pérez, J Gonzalo; Alonso-Ramos, Carlos; Durán-Valdeiglesias, Elena; Cheben, Pavel; Molina-Fernández, Íñigo; Halir, Robert

    2016-08-01

    Subwavelength gratings (SWG) are photonic structures with a period small enough to suppress diffraction, thereby acting as artificial dielectric materials, also called all-dielectric metamaterials. This property has been exploited in many high-performance photonic integrated devices in the silicon-on-insulator (SOI) platform. While SWG waveguides are theoretically lossless, they may exhibit leakage penalty to the substrate due to a combination of reduced modal confinement and finite thickness of the buried oxide (BOX) layer. In this Letter, for the first time, to the best of our knowledge, we analyze substrate leakage losses in SWG waveguides. We establish a direct relation between the effective index of the waveguide mode and the leakage losses which, remarkably, is independent of the geometric parameters of the SWG waveguide. This universal relation is demonstrated both numerically and experimentally, and it provides practical design guidelines to mitigate leakage losses. For BOX thicknesses of 2 and 3 μm, we find negligible leakage losses when the mode effective index is higher than 1.65 and 1.55, respectively. PMID:27472589

  10. Understanding instrumental Stokes leakage in Murchison Widefield Array polarimetry

    NASA Astrophysics Data System (ADS)

    Sutinjo, A.; O'Sullivan, J.; Lenc, E.; Wayth, R. B.; Padhi, S.; Hall, P.; Tingay, S. J.

    2015-01-01

    This paper offers an electromagnetic, more specifically array theory, perspective on understanding strong instrumental polarization effects for planar low-frequency "aperture arrays" with the Murchison Widefield Array (MWA) as an example. A long-standing issue that has been seen here is significant instrumental Stokes leakage after calibration, particularly in Stokes Q at high frequencies. A simple model that accounts for interelement mutual coupling is presented which explains the prominence of Q leakage seen when the array is scanned away from zenith in the principal planes. On these planes, the model predicts current imbalance in the X (E-W) and Y (N-S) dipoles and hence the Q leakage. Although helpful in concept, we find that this model is inadequate to explain the full details of the observation data. This finding motivates further experimentation with more rigorous models that account for both mutual coupling and embedded element patterns. Two more rigorous models are discussed: the "full" and "average" embedded element patterns. The viability of the full model is demonstrated by simulating current MWA practice of using a Hertzian dipole model as a Jones matrix estimate. We find that these results replicate the observed Q leakage to approximately 2 to 5%. Finally, we offer more direct indication for the level of improvement expected from upgrading the Jones matrix estimate with more rigorous models. Using the average embedded pattern as an estimate for the full model, we find that Q leakage of a few percent is achievable.

  11. Gas-path leakage seal for a gas turbine

    DOEpatents

    Wolfe, Christopher E.; Dinc, Osman S.; Bagepalli, Bharat S.; Correia, Victor H.; Aksit, Mahmut F.

    1996-01-01

    A gas-path leakage seal for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the "plane" of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member.

  12. Gas-path leakage seal for a gas turbine

    DOEpatents

    Wolfe, C.E.; Dinc, O.S.; Bagepalli, B.S.; Correia, V.H.; Aksit, M.F.

    1996-04-23

    A gas-path leakage seal is described for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a gas turbine (such as combustor casing segments). The seal includes a generally imperforate foil-layer assemblage which is generally impervious to gas and is located in the leakage-gap. The seal also includes a cloth-layer assemblage generally enclosingly contacting the foil-layer assemblage. In one seal, the first edge of the foil-layer assemblage is left exposed, and the foil-layer assemblage resiliently contacts the first member near the first edge to reduce leakage in the ``plane`` of the cloth-layer assemblage under conditions which include differential thermal growth of the two members. In another seal, such leakage is reduced by having a first weld-bead which permeates the cloth-layer assemblage, is attached to the metal-foil-layer assemblage near the first edge, and unattachedly contacts the first member. 4 figs.

  13. Vadose Zone Remediation of CO2 Leakage from Geologic CO2 Storage Sites

    SciTech Connect

    Zhang, Yingqi; Oldenburg, Curtis M.; Benson, Sally M.

    2004-03-03

    In the unlikely event that CO2 leakage from deep geologic CO2 sequestration sites reaches the vadose zone, remediation measures for removing the CO2 gas plume may have to be undertaken. Carbon dioxide leakage plumes are similar in many ways to volatile organic compound (VOC) vapor plumes, and the same remediation approaches are applicable. We present here numerical simulation results of passive and active remediation strategies for CO2 leakage plumes in the vadose zone. The starting time for the remediation scenarios is assumed to be after a steady-state CO2 leakage plume is established in the vadose zone, and the source of this plume has been cut off. We consider first passive remediation, both with and without barometric pumping. Next, we consider active methods involving extraction wells in both vertical and horizontal configurations. To compare the effectiveness of the various remediation strategies, we define a half-life of the CO2 plume as a convenient measure of the CO2 removal rate. For CO2 removal by passive remediation approaches such as barometric pumping, thicker vadose zones generally require longer remediation times. However, for the case of a thin vadose zone where a significant fraction of the CO2 plume mass resides within the high liquid saturation region near the water table, the half-life of the CO2 plume without barometric pumping is longer than for somewhat thicker vadose zones. As for active strategies, results show that a combination of horizontal and vertical wells is the most effective among the strategies investigated, as the performance of commonly used multiple vertical wells was not investigated.

  14. Analytical Assessment of a Gross Leakage Event Within the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS)

    NASA Technical Reports Server (NTRS)

    Holt, James M.; Clanton, Stephen E.

    2001-01-01

    Results of the International Space Station (ISS) Node 2 Internal Active Thermal Control System (IATCS) gross leakage analysis are presented for evaluating total leakage flow rates and volume discharge caused by a gross leakage event (i.e. open boundary condition). A Systems Improved Numerical Differencing Analyzer and Fluid Integrator (SINDA85/FLUINT) thermal hydraulic mathematical model (THMM) representing the Node 2 IATCS was developed to simulate system performance under steady-state nominal conditions as well as the transient flow effect resulting from an open line exposed to ambient. The objective of the analysis was to determine the adequacy of the leak detection software in limiting the quantity of fluid lost during a gross leakage event to within an acceptable level.

  15. Choosing Actions

    PubMed Central

    Rosenbaum, David A.; Chapman, Kate M.; Coelho, Chase J.; Gong, Lanyun; Studenka, Breanna E.

    2013-01-01

    Actions that are chosen have properties that distinguish them from actions that are not. Of the nearly infinite possible actions that can achieve any given task, many of the unchosen actions are irrelevant, incorrect, or inappropriate. Others are relevant, correct, or appropriate but are disfavored for other reasons. Our research focuses on the question of what distinguishes actions that are chosen from actions that are possible but are not. We review studies that use simple preference methods to identify factors that contribute to action choices, especially for object-manipulation tasks. We can determine which factors are especially important through simple behavioral experiments. PMID:23761769

  16. Geomechanical effects on CO2 leakage through fault zones during large-scale underground injection

    SciTech Connect

    Rinaldi, Antonio P.; Rutqvist, Jonny; Cappa, Frédéric

    2013-12-01

    The importance of geomechanics—including the potential for faults to reactivate during large-scale geologic carbon sequestration operations—has recently become more widely recognized. However, notwithstanding the potential for triggering notable (felt) seismic events, the potential for buoyancy-driven CO2 to reach potable groundwater and the ground surface is actually more important from public safety and storage-efficiency perspectives. In this context, this paper extends the previous studies on the geomechanical modeling of fault responses during underground carbon dioxide injection, focusing on the short-term integrity of the sealing caprock, and hence on the potential for leakage of either brine or CO2 to reach the shallow groundwater aquifers during active injection. We consider stress/strain-dependent permeability and study the leakage through the fault zone as its permeability changes during a reactivation, also causing seismicity. We analyze several scenarios related to the volume of CO2 injected (and hence as a function of the overpressure), involving both minor and major faults, and analyze the profile risks of leakage for different stress/strain-permeability coupling functions. We conclude that whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. Moreover, our analysis shows that induced seismicity associated with fault reactivation may not necessarily open up a new flow path for leakage. Results show a poor correlation between magnitude and amount of fluid leakage, meaning that a single event is generally not enough to substantially change the permeability along the entire fault length. Finally, and consequently, even if some changes in permeability occur, this does not mean that the CO2 will migrate up along the entire fault, breaking through the caprock to enter the overlying aquifer.

  17. Dynamic sealing principles. [design configurations for fluid leakage control

    NASA Technical Reports Server (NTRS)

    Zuk, J.

    1976-01-01

    The fundamental principles governing dynamic sealing operation are discussed. Different seals are described in terms of these principles. Despite the large variety of detailed construction, there appear to be some basic principles, or combinations of basic principles, by which all seals function. They are: (1) selection and control of seal geometry, (2) control of leakage fluid properties, and (3) control of forces acting on leakage fluids. Theoretical and practical considerations in the application of these principles are discussed. Advantages, disadvantages, limitations, and application examples of various conventional and special seals are presented. Fundamental equations governing liquid and gas flows in thin-film seals, which enable leakage calculations to be made, are also presented.

  18. Air Leakage of U.S. Homes: Model Prediction

    SciTech Connect

    Sherman, Max H.; McWilliams, Jennifer A.

    2007-01-01

    Air tightness is an important property of building envelopes. It is a key factor in determining infiltration and related wall-performance properties such as indoor air quality, maintainability and moisture balance. Air leakage in U.S. houses consumes roughly 1/3 of the HVAC energy but provides most of the ventilation used to control IAQ. The Lawrence Berkeley National Laboratory has been gathering residential air leakage data from many sources and now has a database of more than 100,000 raw measurements. This paper uses a model developed from that database in conjunction with US Census Bureau data for estimating air leakage as a function of location throughout the US.

  19. Crack detection and leakage monitoring on reinforced concrete pipe

    NASA Astrophysics Data System (ADS)

    Feng, Qian; Kong, Qingzhao; Huo, Linsheng; Song, Gangbing

    2015-11-01

    Reinforced concrete underground pipelines are some of the most widely used types of structures in water transportation systems. Cracks and leakage are the leading causes of pipeline structural failures which directly results in economic losses and environmental hazards. In this paper, the authors propose a piezoceramic based active sensing approach to detect the cracks and the further leakage of concrete pipelines. Due to the piezoelectric properties, piezoceramic material can be utilized as both the actuator and the sensor in the active sensing approach. The piezoceramic patch, which is sandwiched between protective materials called ‘smart aggregates,’ can be safely embedded into concrete structures. Circumferential and axial cracks were investigated. A wavelet packet-based energy analysis was developed to distinguish the type of crack and determine the further leakage based on different stress wave energy attenuation propagated through the cracks.

  20. An Investigation of Tendon Corrosion-Inhibitor Leakage into Concrete

    SciTech Connect

    Costello, J.F.; Naus, D.J.; Oland, C.B.

    1999-07-05

    During inspections performed at US nuclear power plants several years ago, some of the prestressed concrete containment had experienced leakage of the tendon sheathing filler. A study was conducted to indicate the extent of the leakage into the concrete and its potential effects on concrete properties. Concrete core samples were obtained from the Trojan Nuclear Plant. Examination and testing of the core samples indicated that the appearance of tendon sheathing filler on the surface was due to leakage of the filler from the conduits and its subsequent migration to the concrete surface through cracks that were present. Migration of the tendon sheathing filler was confined to the cracks with no perceptible movement into the concrete. Results of compressive strength tests indicated that the concrete quality was consistent in the containment and that the strength had increased relative to the strength at 28 days age.

  1. Multicenter Analysis of Long-Term Oncologic Impact of Anastomotic Leakage After Laparoscopic Total Mesorectal Excision: The Korean Laparoscopic Colorectal Surgery Study Group.

    PubMed

    Kang, Jeonghyun; Choi, Gyu-Seog; Oh, Jae Hwan; Kim, Nam Kyu; Park, Jun Seok; Kim, Min Jung; Lee, Kang Young; Baik, Seung Hyuk

    2015-07-01

    This study aims to validate the oncologic outcomes of anastomotic leakage (AL) after laparoscopic total mesorectal excision (TME) in a large multicenter cohort. The impact of AL after laparoscopic TME for rectal cancer surgery has not yet been clearly described. This was a multicenter retrospective study of 1083 patients who underwent laparoscopic TME for nonmetastatic rectal cancer (stage 0-III). AL was defined as an anastomotic complication within 30 days of surgery irrespective of requiring a reoperation or interventional radiology. Estimated local recurrence (LR), disease-free survival (DFS), and overall survival (OS) were compared between the leakage group and the no leakage group using the log-rank method. Multivariate Cox-regression analysis was used to adjust confounding for survival. The incidence of AL was 6.4%. Mortality within 30 days of surgery occurred in 1 patient (1.4%) in the leakage group and 2 patients (0.2%) in the no leakage group. The leakage group showed a higher LR rate (6.4% vs 1.8%, P = 0.011). Five-year DFS and OS were significantly lower in the leakage group than the no leakage group (DFS 71.7% vs 82.1%, P = 0.016, OS 81.8% vs 93.5%, P = 0.007). Multivariate analysis showed that AL was an independent poor prognostic factor for DFS and OS (hazard ratio [HR] = 1.6; 95% confidence intervals [CI]: 1.0-2.6; P = 0.042, HR = 2.1; 95% CI: 1.0-4.2; P = 0.028, respectively). AL after laparoscopic TME was significantly associated with an increased rate of LR, systemic recurrence and poor OS. PMID:26200636

  2. An efficient numerical simulation of coupled thermal-hydro-mechanical process in CO2 leakage through fractured caprocks

    NASA Astrophysics Data System (ADS)

    Wu, Y. S.; Huang, Z.; Winterfeld, P. H.

    2014-12-01

    The safety of CO2 sequestration in geological formations relies on the integrity of the caprock. However, the elevated fluid pressure during CO2 injection changes the stress states in the caprock, and may lead to reactivate pre-existing fractures or even fracture the caprock. It is necessary to develop an efficient and practical monitor technology to detect and identify CO2 leakage pathways. To this end, we should understand the transport behavior of CO2 coupled with geomechanical effects during injection. In this work, we first developed an efficient parallel fully-coupled thermal-hydro-mechanical simulator to model CO2 transport in geological formations. The numerical model was verified through classical problems with analytical solutions. Then, based on this simulator, we investigated the fluid flow behavior when CO2 leakage occurs through fluid-driven fracturing zones. We proposed an implicit, physics-based model to simulate the fluid-driven fracturing process by using several practical correlations, including fracturing pressure functions, porosity/permeability-stress relationships, which can be obtained by lab experiments. A set of numerical simulations have been conducted by considering various scenarios, such as different injection rates, locations and distributions of fracture zones, and initial fracture permeability. The numerical results show that there are several characteristics can be used to detect CO2 leakage pathways, and it is possible to develop an advanced inverse modeling and monitoring technology to identify leakage locations, times and rates using measured pressure data of permanent downhole gauges and our simulator.

  3. Antifreeze glycoproteins inhibit leakage from liposomes during thermotropic phase transitions.

    PubMed Central

    Hays, L M; Feeney, R E; Crowe, L M; Crowe, J H; Oliver, A E

    1996-01-01

    Antifreeze glycoproteins (AFGPs), found in the blood of polar fish at concentrations as high as 35 g/liter, are known to prevent ice crystal growth and depress the freezing temperature of the blood. Previously, Rubinsky et al. [Rubinsky, B., Mattioli, M., Arav, A., Barboni, B. & Fletcher, G. L. (1992) Am. J. Physiol. 262, R542-R545] provided evidence that AFGPs block ion fluxes across membranes during cooling, an effect that they ascribed to interactions with ion channels. We investigated the effects of AFGPs on the leakage of a trapped marker from liposomes during chilling. As these liposomes are cooled through the transition temperature, they leak approximately 50% of their contents. Addition of less than 1 mg/ml of AFGP prevents up to 100% of this leakage, both during chilling and warming through the phase transition. This is a general effect that we show here applies to liposomes composed of phospholipids with transition temperatures ranging from 12 degrees C to 41 degrees C. Because these results were obtained with liposomes composed of phospholipids alone, we conclude that the stabilizing effects of AFGPs on intact cells during chilling reported by Rubinsky et al. may be due to a nonspecific effect on the lipid components of native membranes. There are other proteins that prevent leakage, but only under specialized conditions. For instance, antifreeze proteins, bovine serum albumin, and ovomucoid all either have no effect or actually induce leakage. Following precipitation with acetone, all three proteins inhibited leakage, although not to the extent seen with AFGPs. Alternatively, there are proteins such as ovotransferrin that have no effect on leakage, either before or after acetone precipitation. PMID:8692905

  4. An Explanation of the Varied Measurements of Gas Field Methane Leakage

    NASA Astrophysics Data System (ADS)

    Evans, W. F.; McHugh, M. J.

    2014-12-01

    In situ engineering measurements of natural gas well sites indicate leakage rates with a mean rate of 1.5% of the gas production rate from individual wells. These have been made at several gas basins using in situ measurements. These in situ engineering measurements are reported as the fugitive emission rates to the UNCCC by the EPA. On the other hand, atmospheric measurements at altitudes above the surface by several atmospheric groups indicate that gas fields are leaking at an average rate of over 9 %. Papers have been published in several highly reputable journals by government and university scientists. Both groups have been criticizing the methodologies of the opposite group. We propose that a more likely explanation is that both groups are correct. Although this appears as a direct conflict with one group on each side, a careful analysis shows that the two groups are measuring different air parcels. This is the only explanation which will explain the apparent conflicting situation. This can be understood if the basins in which the wells are sited are actually leaking from the bed rock formations in which the wells are drilled. If the geology of the natural gas basins is examined in detail, then the situation becomes understandable. Many basins contain gas in fault traps. These faults often leak, particularly if there is a small earthquake. The leaks can follow tilted layers, resulting in vertical transport of gas along the slanted layer cracks. This leakage may emerge into the atmosphere at large distances from the actual gas well under measurement. Fracking can obviously increase the leakage from a valley gas field. The methane leaks could alter the budgets of greenhouse gases reported by various gas producing countries by significant amounts. The potential increases and altered budgets for various countries as reported to the UNCCC are estimated and reported in this presentation. The fraction of these unreported leaks which should be reported will have to

  5. Measured effect of step axial location on labyrinth seal leakage

    SciTech Connect

    Morrison, G.L.; Rhode, D.L. )

    1992-12-01

    An advanced, finite volume code has been extensively used in a parametric design study of simple stepped seals, in order to ascertain a leakage-minimizing optimal design and test it, in conjunction with the baseline case of the wear-ring seal of a high pressure pump. It is found that a significant leakage effect arises from this shifting of the rotor and stator sealing surfaces; at extremely low rpm, a significant shaft speed effect occurs for the optimized design in some shaft locations. 3 refs.

  6. Measured effect of step axial location on labyrinth seal leakage

    NASA Astrophysics Data System (ADS)

    Morrison, G. L.; Rhode, D. L.

    1992-12-01

    An advanced, finite volume code has been extensively used in a parametric design study of simple stepped seals, in order to ascertain a leakage-minimizing optimal design and test it, in conjunction with the baseline case of the wear-ring seal of a high pressure pump. It is found that a significant leakage effect arises from this shifting of the rotor and stator sealing surfaces; at extremely low rpm, a significant shaft speed effect occurs for the optimized design in some shaft locations.

  7. Measured effect of step axial location on labyrinth seal leakage

    NASA Technical Reports Server (NTRS)

    Morrison, G. L.; Rhode, D. L.

    1992-01-01

    An advanced, finite volume code has been extensively used in a parametric design study of simple stepped seals, in order to ascertain a leakage-minimizing optimal design and test it, in conjunction with the baseline case of the wear-ring seal of a high pressure pump. It is found that a significant leakage effect arises from this shifting of the rotor and stator sealing surfaces; at extremely low rpm, a significant shaft speed effect occurs for the optimized design in some shaft locations.

  8. Leakage detection of oil pipeline using distributed fiber optic sensor

    NASA Astrophysics Data System (ADS)

    Shan, Song; Wang, Li; Zhou, Jinfeng

    2007-07-01

    A system of distributed optical fiber sensor has presented based on the optical fiber sensor technology and detected the oil pipeline leakage using Mach-Zehnder optical interferometer. There are two interferential signals from sensor and reference light to put in computer has been analyzed using the analysis software LabVIEW of National Instruments' that can operate for the cross-correlation function, then compare the correlation peak to obtain the disturbance of oil leakage location, the detection precision 200m at around 50km for pipeline in the high speed sampling and data signal processing has obtained.

  9. Leakage detection using fiber optics distributed temperature monitoring

    NASA Astrophysics Data System (ADS)

    Nikles, Marc; Vogel, Bernhard H.; Briffod, Fabien; Grosswig, Stephan; Sauser, Florian; Luebbecke, Steffen; Bals, Andre; Pfeiffer, Thomas

    2004-07-01

    The monitoring of temperature profiles over long distance by means of optical fibers represents a highly efficient way to perform leakage detection along pipelines, in dams, dykes, or tanks... Different techniques have been developed taking advantages of the fiber geometry and of optical time domain analysis for the localization of the information. Among fiber optics distributed temperature sensing techniques, Brillouin-based systems have demonstrated to have the best potential for applications over distances up to several tens of kilometers. The key features and performances are reviewed in the present article and a 55km pipeline equipped with a fiber optics leakage detection system is presented as a case study.

  10. Atlantic multi-decadal oscillation covaries with Agulhas leakage

    SciTech Connect

    Biastoch, Arne; Durgadoo, Jonathan V.; Morrison, Adele K.; van Sebille, Erik; Weijer, Wilbert; Griffies, Stephen M.

    2015-12-10

    The interoceanic transfer of seawater between the Indian Ocean and the Atlantic, ‘Agulhas leakage’, forms a choke point for the overturning circulation in the global ocean. Here, by combining output from a series of high-resolution ocean and climate models with in situ and satellite observations, we construct a time series of Agulhas leakage for the period 1870–2014. The time series demonstrates the impact of Southern Hemisphere westerlies on decadal timescales. Agulhas leakage shows a correlation with the Atlantic Multi-decadal Oscillation on multi-decadal timescales; the former leading by 15 years. Lastly, this is relevant for climate in the North Atlantic.

  11. Leakage neutron radiation in a medical electron accelerator

    NASA Astrophysics Data System (ADS)

    Paredes, Lydia; Balcazar, Miguel; Genis, Roberto; Ortiz, Raúl

    2001-10-01

    A simple method was used for the calculation of neutron yield produced by main components of medical electron accelerator head, using a simplified geometric model with spherical-shell for the head shielding made of different materials. The leakage neutron radiation on the patient plane and outside the patient plane at one meter from the x-ray target for a Varian accelerator model Clinac 2100C was evaluated experimentally, using Panasonic UD-802 and UD-809 thermoluminescent dosimeters and CR-39 nuclear track dosimeters. The measured values of leakage neutron radiation were lower than the limits specified in the NCRP-102 and IEC 60601-2-1-Ed.2.0 reports.

  12. Quadrature Mixer LO Leakage Suppression Through Quadrature DC Bias

    SciTech Connect

    BALDWIN, JESSE G; DUBBERT, DALE F.

    2002-05-01

    A new concept has been developed which allows direct-to-RF conversion of digitally synthesized waveforms. The concept named Quadrature Error Corrected Digital Waveform Synthesis (QECDWS) employs quadrature amplitude and phase predistortion to the complex waveform to reduce the undesirable quadrature image. Another undesirable product of QECDWS-based RF conversion is the Local Oscillator (LO) leakage through the quadrature upconverter (mixer). A common technique for reducing this LO leakage is to apply a quadrature bias to the mixer I and Q inputs. This report analyzes this technique through theory, lab measurement, and data analysis for a candidate quadrature mixer for Synthetic Aperture Radar (SAR) applications.

  13. Experimental study of heterogeneity-induced capillary trapping in the context of leakage from geologic carbon sequestration sites

    NASA Astrophysics Data System (ADS)

    Liang, B.; Clarens, A. F.

    2014-12-01

    Leakage of CO2 from geologic carbon sequestration sites could undermine the long-term goal of reducing emissions to the atmosphere. Despite this, leakage processes, especially the vertical transport of gases through geologic formations overlaying target repositories, are poorly characterized. The goal of this work was to experimentally assess how sub-basin scale heterogeneity in overlaying formations could reduce CO2 leakage. High-pressure columns packed with sand and glass beads of different sizes were used to create a capillary barrier, which is an analog of low-permeability inter-beds. Transport of the resulting plume was recorded in real time using electrical resistivity. The effect of pressure, temperature, permeability, surface wettability, and CO2 flow rate were all assessed. Real-time monitoring and quantification of CO2 saturation suggests that capillary heterogeneity trapping is primarily controlled by permeability contrast, pressure, temperature and water/CO2 wettability on mineral surfaces. The amount of trapping was considerably enhanced when permeability contrasted increased, showing a good agreement with equilibrium capillary pressure - saturation analysis in the literature. Temperature and pressure controlled experiments demonstrated the sensitivity of capillary trapping to geothermal and pressure gradient. Wettability alterations also increased initial trapping when more CO2-philic materials is presented and a much greater increase in residual trapping (defined as 10 pore volume water re-imbibition). Variation of leakage rate was not shown to result in significant difference in the overall saturation values, but the stability of the trapped plume was reduced at high CO2 injection rates. These results suggest that local capillary trapping could contribute to secondary trapping and slow the buoyancy-driven rise of CO2. These measurements could have important implications for minimizing risk associated with leakage from carbon sequestration sites.

  14. Intentional Action and Action Slips.

    ERIC Educational Resources Information Center

    Heckhausen, Heinz; Beckmann, Jurgen

    1990-01-01

    An explanation of action slips is offered that examines controlled actions in the context of an intentional behavior theory. Actions are considered guided by mentally represented intentions, subdivided into goal intentions and contingent instrumental intentions. Action slips are categorized according to problem areas in the enactment of goal…

  15. Controls on hydrocarbon generation and leakage in South Atlantic conjugate margins: A comparative approach.

    NASA Astrophysics Data System (ADS)

    Marcano, Gabriela; Anka, Zahie; di Primio, Rolando

    2013-04-01

    We present a regional comparative analysis of the possible first-order internal and external factors controlling source rock (SR) maturation and hydrocarbon (HC) generation and leakage in two pairs of conjugate margins across the South Atlantic: the Brazil (Campos Basin)-Angola (Lower Congo Basin) margins located in the "central segment", and the Argentina (Colorado Basin)-South Africa (Orange Basin) in the "southern segment". Our approach is based on the analysis and integration of borehole data, numerical modeling, 2D seismic reflection data, and published reports. Coupling of modeling results, sedimentation rate calculation and seal-bypass system analysis reveals that: (1) oil window is reached by syn-rift SRs in the southern segment during the Early to Late Cretaceous when thermal subsidence is still active, whilst in the central segment they reach it in Late-Cretaceous- Neogene during a salt remobilization phase, and (2) early HC generation from post-rift SRs in the southern segment and from all SRs in the central segment appears controlled mainly by episodes of increased sedimentation rates. These latter seem associated to the Andes uplift history for the western South Atlantic basins (Campos and Colorado) and to a possibly climate-driven response for the eastern South Atlantic basins (Orange and Lower Congo). Interestingly, Paleogene leakage indicators, which were identified in the Argentina-South Africa conjugate margins, occur contemporaneously to low sedimentation rates periods. Nonetheless, present-day leakage indicators, which were also identified in both pair of conjugate margins, might be related to seal failure events associated to eustatic sea-level drops.

  16. The simulated effects of wastewater-management actions on the hydrologic system and nitrogen-loading rates to wells and ecological receptors, Popponesset Bay Watershed, Cape Cod, Massachusetts

    USGS Publications Warehouse

    Walter, Donald A.

    2013-01-01

    The discharge of excess nitrogen into Popponesset Bay, an estuarine system on western Cape Cod, has resulted in eutrophication and the loss of eel grass habitat within the estuaries. Septic-system return flow in residential areas within the watershed is the primary source of nitrogen. Total Maximum Daily Loads (TMDLs) for nitrogen have been assigned to the six estuaries that compose the system, and local communities are in the process of implementing the TMDLs by the partial sewering, treatment, and disposal of treated wastewater at wastewater-treatment facilities (WTFs). Loads of waste-derived nitrogen from both current (1997–2001) and future sources can be estimated implicitly from parcel-scale water-use data and recharge areas delineated by a groundwater-flow model. These loads are referred to as “instantaneous” loads because it is assumed that the nitrogen from surface sources is delivered to receptors instantaneously and that there is no traveltime through the aquifer. The use of a solute-transport model to explicitly simulate the transport of mass through the aquifer from sources to receptors can improve implementation of TMDLs by (1) accounting for traveltime through the aquifer, (2) avoiding limitations associated with the estimation of loads from static recharge areas, (3) accounting more accurately for the effect of surface waters on nitrogen loads, and (4) determining the response of waste-derived nitrogen loads to potential wastewater-management actions. The load of nitrogen to Popponesset Bay on western Cape Cod, which was estimated by using current sources as input to a solute-transport model based on a steady-state flow model, is about 50 percent of the instantaneous load after about 7 years of transport (loads to estuary are equal to loads discharged from sources); this estimate is consistent with simulated advective traveltimes in the aquifer, which have a median of 5 years. Model-calculated loads originating from recharge areas reach 80

  17. USAF bioenvironmental noise data handbook. Volume 168: MB-3 tester, pressurized cabin leakage, aircraft

    NASA Astrophysics Data System (ADS)

    Rau, T. H.

    1982-06-01

    The MB-3 Tester is an electric motor-driven cabin leakage tester designed to furnish pressurized air to the aircraft at controlled pressures and temperatures during ground pressurization of aircraft cockpits and pressurized compartments. This report provides measured data defining the bioacoustic environments produced by this unit operating at a normal rated/load condition. Near-field data are reported for 37 locations in a wide variety of physical and psychoacoustic measures: overall and band sound pressure levels, C-weighted and A-weighted sound levels, preferred speech interference level, perceived noise level, and limiting times for total daily exposure of personnel with and without standard Air Force ear protectors.

  18. Using the Bongwana natural CO2 release to understand leakage processes and develop monitoring

    NASA Astrophysics Data System (ADS)

    Jones, David; Johnson, Gareth; Hicks, Nigel; Bond, Clare; Gilfillan, Stuart; Kremer, Yannick; Lister, Bob; Nkwane, Mzikayise; Maupa, Thulani; Munyangane, Portia; Robey, Kate; Saunders, Ian; Shipton, Zoe; Pearce, Jonathan; Haszeldine, Stuart

    2016-04-01

    Natural CO2 leakage along the Bongwana Fault in South Africa is being studied to help understand processes of CO2 leakage and develop monitoring protocols. The Bongwana Fault crops out over approximately 80 km in KwaZulu-Natal province, South Africa. In outcrop the fault is expressed as a broad fracture corridor in Dwyka Tillite, with fractures oriented approximately N-S. Natural emissions of CO2 occur at various points along the fault, manifest as travertine cones and terraces, bubbling in the rivers and as gas fluxes through soil. Exposed rock outcrop shows evidence for Fe-staining around fractures and is locally extensively kaolinitised. The gas has also been released through a shallow water well, and was exploited commercially in the past. Preliminary studies have been carried out to better document the surface emissions using near surface gas monitoring, understand the origin of the gas through major gas composition and stable and noble gas isotopes and improve understanding of the structural controls on gas leakage through mapping. In addition the impact of the leaking CO2 on local water sources (surface and ground) is being investigated, along with the seismic activity of the fault. The investigation will help to build technical capacity in South Africa and to develop monitoring techniques and plans for a future CO2 storage pilot there. Early results suggest that CO2 leakage is confined to a relatively small number of spatially-restricted locations along the weakly seismically active fault. Fracture permeability appears to be the main method by which the CO2 migrates to the surface. The bulk of the CO2 is of deep origin with a minor contribution from near surface biogenic processes as determined by major gas composition. Water chemistry, including pH, DO and TDS is notably different between CO2-rich and CO2-poor sites. Soil gas content and flux effectively delineates the fault trace in active leakage sites. The fault provides an effective testing ground for

  19. BRIEF COMMUNICATIONS: Dynamic method for measurement of rate constants of heterogeneous chemical reactions taking place under the action of laser radiation

    NASA Astrophysics Data System (ADS)

    Kirichenko, N. A.; Luk'yanchuk, B. S.; Sapetskiĭ, A. N.

    1981-10-01

    A new dynamic method is proposed for determination of the rate constants of heterogeneous reactions. This involves measuring the temperature and its derivative during laser heating of solid targets, and also the finite thickness of the layer of the chemical compound being formed. The method can be used to find the rate constants obeying an arbitrary kinetic law and differs from traditional methods of measurement in being more accurate and less laborious.

  20. Can paternal leakage maintain sexually antagonistic polymorphism in the cytoplasm?

    PubMed Central

    Kuijper, B; Lane, N; Pomiankowski, A

    2015-01-01

    A growing number of studies in multicellular organisms highlight low or moderate frequencies of paternal transmission of cytoplasmic organelles, including both mitochondria and chloroplasts. It is well established that strict maternal inheritance is selectively blind to cytoplasmic elements that are deleterious to males – ’mother's curse’. But it is not known how sensitive this conclusion is to slight levels of paternal cytoplasmic leakage. We assess the scope for polymorphism when individuals bear multiple cytoplasmic alleles in the presence of paternal leakage, bottlenecks and recurrent mutation. When fitness interactions among cytoplasmic elements within an individual are additive, we find that sexually antagonistic polymorphism is restricted to cases of strong selection on males. However, when fitness interactions among cytoplasmic elements are nonlinear, much more extensive polymorphism can be supported in the cytoplasm. In particular, mitochondrial mutants that have strong beneficial fitness effects in males and weak deleterious fitness effects in females when rare (i.e. ’reverse dominance’) are strongly favoured under paternal leakage. We discuss how such epistasis could arise through preferential segregation of mitochondria in sex-specific somatic tissues. Our analysis shows how paternal leakage can dampen the evolution of deleterious male effects associated with predominant maternal inheritance of cytoplasm, potentially explaining why ’mother's curse’ is less pervasive than predicted by earlier work. PMID:25653025

  1. Osmotic Stressing, Membrane Leakage, and Fluorescence: An Introductory Biochemistry Demonstration

    ERIC Educational Resources Information Center

    Seu, Kalani J.

    2015-01-01

    A fluorescence demonstration is described that incorporates several fundamental aspects of an introductory biochemistry course. A variation of a known leakage assay is utilized to prepare vesicles containing a quenched fluorophore. The vesicles are exposed to several osmotic environments ranging from isotonic to hypotonic. The degree of vesicle…

  2. 49 CFR 178.345-13 - Pressure and leakage tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... be tested with the adjacent cargo tanks empty and at atmospheric pressure. Each closure, except... 49 Transportation 2 2010-10-01 2010-10-01 false Pressure and leakage tests. 178.345-13 Section 178... PACKAGINGS Specifications for Containers for Motor Vehicle Transportation § 178.345-13 Pressure and...

  3. 49 CFR 178.346-5 - Pressure and leakage tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... CFR 63.425(e). To satisfy the leakage test requirements of this paragraph, the test specified in 40 CFR 63.425(e)(1) must be conducted using air. The hydrostatic test alternative permitted under Appendix A to 40 CFR Part 60 (“Method 27—Determination of Vapor Tightness of Gasoline Delivery Tank...

  4. Pacemaker failures characterized by continuous direct current leakage.

    PubMed

    Fisher, J D; Furman, S; Parker, B; Escher, D J

    1976-06-01

    Pulse generator failure caused by continuous leakage of direct current through an output capacitor has not previously been appreciated. Routine post-explant electronic evaluation has identified the defect in six implanted and one external pulse generator. The constant direct current in the implantable units, 0.14 to 0.26 milliamperes, is in the range that produces ventricular arrhythmias in dogs although this did not occur in our patients. Evidence of local myocardial damage existed in four cases and of electrode deterioration in three. The implant failures occurred without warning and in four cases within 2 weeks of demonstrated normal function, blunting the predictive benefits of pacemaker monitoring programs. Capacitor discharge circuits used in many pacers are inherently capable of developing direct current leakage in the event of output capacitor short circuit. In one model of pacemakers such continuous direct current leakage caused 8.3 percent (3 of 36) of pulse generator failures, widely scattered in time at 23, 27 and 46 months after implant. Capacitor short circuit causing constant direct current leakage can masquerade as primary battery failure and should be suspected when cessation of pacer function is associated with increased threshold or poor myocardial electrogram without evidence of wire break or displacement. PMID:1274862

  5. 42 CFR 84.123 - Exhalation valve leakage test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test. 84.123 Section 84.123 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Gas Masks §...

  6. Thresholds of information leakage for speech security outside meeting rooms.

    PubMed

    Robinson, Matthew; Hopkins, Carl; Worrall, Ken; Jackson, Tim

    2014-09-01

    This paper describes an approach to provide speech security outside meeting rooms where a covert listener might attempt to extract confidential information. Decision-based experiments are used to establish a relationship between an objective measurement of the Speech Transmission Index (STI) and a subjective assessment relating to the threshold of information leakage. This threshold is defined for a specific percentage of English words that are identifiable with a maximum safe vocal effort (e.g., "normal" speech) used by the meeting participants. The results demonstrate that it is possible to quantify an offset that links STI with a specific threshold of information leakage which describes the percentage of words identified. The offsets for male talkers are shown to be approximately 10 dB larger than for female talkers. Hence for speech security it is possible to determine offsets for the threshold of information leakage using male talkers as the "worst case scenario." To define a suitable threshold of information leakage, the results show that a robust definition can be based upon 1%, 2%, or 5% of words identified. For these percentages, results are presented for offset values corresponding to different STI values in a range from 0.1 to 0.3. PMID:25190390

  7. 49 CFR 192.723 - Distribution systems: Leakage surveys.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution systems: Leakage surveys. 192.723 Section 192.723 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE...

  8. Detectivity of gas leakage based on electromagnetic radiation transfer

    NASA Astrophysics Data System (ADS)

    Long, Yunting; Wang, Lingxue; Li, Jiakun; Zhang, Changxing; Zhang, Bei

    2011-05-01

    Standoff detection of gas leakage is a fundamental need in petrochemical and power industries. The passive gas imaging system using thermal imager has been proven to be efficient to visualize leaking gas which is not visible to the naked eye. The detection probability of gas leakage is the basis for designing a gas imaging system. Supposing the performance parameters of the thermal imager are known, the detectivity based on electromagnetic radiation transfer model to image gas leakage is analyzed. This model takes into consideration a physical analysis of the gas plume spread in the atmosphere-the interaction processes between the gas and its surrounding environment, the temperature of the gas and the background, the background surface emissivity, and also gas concentration, etc. Under a certain environmental conditions, through calculating the radiation reaching to the detector from the camera's optical field of view, we obtain an entity "Gas Equivalent Blackbody Temperature Difference (GEBTD)" which is the radiation difference between the on-plume and off-plume regions. Comparing the GEBTD with the Noise Equivalent Temperature Difference (NETD) of the thermal imager, we can know whether the system can image the gas leakage. At last, an example of detecting CO2 gas by JADE MWIR thermal imager with a narrow band-pass filter is presented.

  9. Visual Inspection of Water Leakage from Ground Penetrating Radar Radargram

    NASA Astrophysics Data System (ADS)

    Halimshah, N. N.; Yusup, A.; Mat Amin, Z.; Ghazalli, M. D.

    2015-10-01

    Water loss in town and suburban is currently a significant issue which reflect the performance of water supply management in Malaysia. Consequently, water supply distribution system has to be maintained in order to prevent shortage of water supply in an area. Various techniques for detecting a mains water leaks are available but mostly are time-consuming, disruptive and expensive. In this paper, the potential of Ground Penetrating Radar (GPR) as a non-destructive method to correctly and efficiently detect mains water leaks has been examined. Several experiments were designed and conducted to prove that GPR can be used as tool for water leakage detection. These include instrument validation test and soil compaction test to clarify the maximum dry density (MDD) of soil and simulation studies on water leakage at a test bed consisting of PVC pipe burying in sand to a depth of 40 cm. Data from GPR detection are processed using the Reflex 2D software. Identification of water leakage was visually inspected from the anomalies in the radargram based on GPR reflection coefficients. The results have ascertained the capability and effectiveness of the GPR in detecting water leakage which could help avoiding difficulties with other leak detection methods.

  10. Blower-door techniques for measuring interzonal leakage

    SciTech Connect

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  11. Exploitation of Unintentional Information Leakage from Integrated Circuits

    ERIC Educational Resources Information Center

    Cobb, William E.

    2011-01-01

    The information leakage of electronic devices, especially those used in cryptographic or other vital applications, represents a serious practical threat to secure systems. While physical implementation attacks have evolved rapidly over the last decade, relatively little work has been done to allow system designers to effectively counter the…

  12. Lidar technologies application to leakage detection in oil product pipelines

    NASA Astrophysics Data System (ADS)

    Petoukhov, Valery M.; Petoukhova, Zaytuna K.; Akhtiamov, Rishad A.; Il'in, German I.; Morozov, Oleg G.; Pol'ski, Yuri E.

    1999-02-01

    Most of oil product pipelines have a design life from 20 till 25 years. The first attributes of their destruction are leakage of oil products. In our paper we try to discuss advantages and disadvantages of one of the main nondestructive techniques to oil product pipelines testing-- lidar technologies and its application to leakage detection. We consider applications of two basical lidars--IR-cw--LFM lidar (DIAL-system) for methane determining and pulsed lidar based on YAG:Nd3+ laser for registration of liquid oil products fluoristation. Set-ups for both lidars were made in Tupolev Kazan State Technical University and were used on the area of Sredne-Volgsk TransNefteProduct oil company for pipelines testing. Theoretical considerations and experimental results are presented. Some technical problems of specified lidars and their decisions are discussed. Particularly we present two frequency technique for He-Ne-DIAL-system and peculiarities of pumping source with high repetition range for pulsed laser. Its allow to improve characteristics of lidars. Possibilities of computerized leak detection system based on two specified lidars are discussed. It is shown that system can analyze leakage of different oil products, can determine leakage location (the second function of lidars-laser locator), can evaluate degree of damages. The structure of system and its peculiarities are shown.

  13. Hydrogeology from 10,000 ft below: lessons learned in applying pulse testing for leakage detection in a carbon sequestration formation

    NASA Astrophysics Data System (ADS)

    Sun, A. Y.; Lu, J.; Hovorka, S. D.; Freifeld, B. M.; Islam, A.

    2015-12-01

    Monitoring techniques capable of deep subsurface detection are desirable for early warning and leakage pathway identification in geologic carbon storage formations. This work investigates the feasibility of a leakage detection technique based on pulse testing, which is a traditional hydrogeological characterization tool. In pulse testing, the monitoring reservoir is stimulated at a fixed frequency and the acquired pressure perturbation signals are analyzed in the frequency domain to detect potential deviations in the reservoir's frequency domain response function. Unlike traditional time-domain analyses, the frequency-domain analysis aims to minimize the interference of reservoir noise by imposing coded injection patterns such that the reservoir responses to injection can be uniquely determined. We have established the theoretical basis of the approach in previous work. Recently, field validation of this pressure-based, leakage detection technique was conducted at a CO2-EOR site located in Mississippi, USA. During the demonstration, two sets of experiments were performed using 90-min and 150-min pulsing periods, for both with and without leak scenarios. Because of the lack of pre-existing leakage pathways, artificial leakage CO2 was simulated by rate-controlled venting from one of the monitoring wells. Our results show that leakage events caused a significant deviation in the amplitude of the frequency response function, indicating that pulse testing may be used as a cost-effective monitoring technique with a strong potential for automation.

  14. Comparison of natural aquifer geochemical variability with uncertainty from model-predicted CO2 induced geochemical changes: How detectable is leakage from carbon sequestration sites?

    NASA Astrophysics Data System (ADS)

    Navarre-Sitchler, A. K.; Moore, J.

    2012-12-01

    in hydrologic parameters and leakage rates was quantified using stochastic approaches in reactive transport models. Comparison of the model results to groundwater variability provides guidance for the development of geochemical monitoring of CO2 leakage into shallow aquifers.

  15. Environmental Action.

    ERIC Educational Resources Information Center

    Lott, Jesse; Allen, Rodney F.

    This booklet, a general guide to citizen eco-action, discusses a plan of action on community environmental problems. It offers factors to be considered in any community eco-action situation, but it is not a rigid set of rules. An overview identifies seven key ideas of environmental issues, including the universal participation of all humans in the…

  16. Systematic Method for Evaluating Extraction and Injection Flow Rates for 100-KR-4 and 100-HR-3 Groundwater Operable Unit Pump-and-Treat Interim Actions for Hydraulic Containment

    SciTech Connect

    Spiliotopoulos, Alexandros A.

    2013-03-20

    This document describes a systematic method to develop flow rate recommendations for Pump-and-Treat (P&T) extraction and injection wells in 100-KR-4 and 100-HR-3 Groundwater Operable Units (OU) of the Hanford Site. Flow rate recommendations are developed as part of ongoing performance monitoring and remedy optimization of the P&T interim actions to develop hydraulic contairnnent of the dissolved chromium plume in groundwater and protect the Columbia River from further discharges of groundwater from inland. This document details the methodology and data required to infer the influence of individual wells near the shoreline on hydraulic containment and river protection and develop flow rate recommendations to improve system performance and mitigate potential shortcomings of the system configuration in place.

  17. Determining vertical leakage from the Great Artesian Basin, Australia, through up-scaling field estimates of phreatic evapotranspiration

    NASA Astrophysics Data System (ADS)

    Costelloe, J. F.; Matic, V.; Western, A. W.; Walker, J. P.; Tyler, M.

    2015-10-01

    Understanding the water balance of large groundwater systems is fundamental for the sustainable management of the resource. The vertical leakage (i.e. discharge to upper aquifers or the unconfined water table) component of the Great Artesian Basin (GAB) is an example of a poorly constrained but large component of the water balance of Australia's largest groundwater resource. Field estimates of phreatic evapotranspiration (ET) were made at discharge zones along the southwestern margin of the GAB using eddy covariance station and micro-lysimeter measurements, and inversion of chloride/isotope soil profile measurements. The field estimates were assigned to three major landforms associated with areas of increasingly higher evaporative discharge and progressively decreasing depths to the water table. These landforms were mapped using remote sensing and digital elevation data, with characteristically higher soil moisture, salt precipitation, and lower surface temperature compared to areas distal to discharge zones. Based on the field measurements, broad ranges of phreatic ET (0.5-10, 10-100 and 100-300 mm y-1) were assigned to the major land-types. The higher phreatic ET discharge zones mapped by supervised classification of satellite data are 8-28% of the total regional vertical leakage component estimated by numerical modelling of the GAB. In comparison, the higher discharge zones estimated by landform mapping are 73-251% of the total vertical leakage component estimated by modelling. The mapped distribution of the high discharge areas has important implications for modelling of the GAB. In the western sub-basin, most of the estimated recharge can be accounted for by phreatic ET in the high discharge zones located around the Basin margins, implying that vertical leakage rates distal to the margins are very low and that discharge may exceed current recharge. In contrast, the results for the eastern sub-basin suggest that vertical leakage rates around the South

  18. Depression of the Thoracolumbar Posterior Vertebral Body on the Estimation of Cement Leakage in Vertebroplasty and Kyphoplasty Operations

    PubMed Central

    Chen, Hao; Jia, Pu; Bao, Li; Feng, Fei; Yang, He; Li, Jin-Jun; Tang, Hai

    2015-01-01

    Background: The cross-section of thoracolumbar vertebral body is kidney-shaped with depressed posterior boundary. The anterior wall of the vertebral canal is separated from the posterior wall of the vertebral body on the lateral X-ray image. This study was designed to determine the sagittal distance between the anterior border of the vertebral canal and the posterior border of the vertebral body (DBCV) and to analyze the potential role of DBCV in the estimation of cement leakage during percutaneous vertebroplasty (PVP) or percutaneous kyphoplasty (PKP). Methods: We retrospectively recruited 233 patients who had osteoporotic vertebral compression fractures and were treated with PVP or PKP. Computed tomography images of T11–L2 normal vertebrae were measured to obtain DBCV. The distance from cement to the posterior wall of the vertebral body (DCPW) of thoracolumbar vertebrae was measured from C-arm images. The selected vertebrae were divided into two groups according to DCPW, with the fracture levels, fracture grades and leakage rates of the two groups compared. A relative operating characteristic (ROC) curve was applied to determine whether the DCPW difference can be used to estimate the degree of cement leakage. The data were processed by statistical software SPSS version 21.0 using independent sample t-test and Chi-square tests. Results: The maximum DBCV was 6.40 mm and the average DBCV was 3.74 ± 0.95 mm. DBCV appeared to be longer in males than in females, but the difference was not statistically significant. The average DCPW of type-B leakage vertebrae (2.59 ± 1.20 mm) was shorter than that of other vertebrae (7.83 ± 2.38 mm, P < 0.001). The leakage rate of group DCPW ≤6.40 mm was lower than that of group DCPW >6.40 mm for type-C and type-S, but much higher for type-B. ROC curve revealed that DCPW only has a predictive value for type-B leakage (area under the curve: 0.98, 95% confidence interval: 0.95–0.99, P < 0.001), and when the cut-off value was 4

  19. Induced seismicity and CO2 leakage through fault zones during large-scale underground injection in a multilayered sedimentary system

    NASA Astrophysics Data System (ADS)

    Pio Rinaldi, Antonio; Rutqvist, Jonny; Jeanne, Pierre; Cappa, Frederic; Guglielmi, Yves

    2014-05-01

    whereas it is very difficult to predict how much fault permeability could change upon reactivation, this process can have a significant impact on the leakage rate. Moreover, our analysis shows that induced seismicity associated with fault reactivation may not necessarily open up a new flow path for leakage. Results show a poor correlation between magnitude and amount of fluid leakage, meaning that a single event is generally not enough to substantially change the permeability along the entire fault length. In the second part of this work we address the three following questions: (1) is there a link between fault-zone architecture and fault reactivation by CO2 injection? (2) what is the impact of the fault architecture on the induced seismicity and on CO2 leakage? and (3) how do caprock and reservoir thickness impact the results? We analyze the hydromechanical behavior of a fault zone represented either by: (i) a continuous damage zone, or by a discontinuous damage zone caused by (ii) variations in lithology of the different layers (shale caprock and limestone aquifers), and also by (iii) the initial properties of the sedimentary layers within the injection reservoir itself. We use the model to estimate the moment magnitude associated with a sudden fault slip event as well as the amount of CO2 migrating from the injection aquifer and upwards across the primary caprock located just above the injection aquifer after a long-term post-injection period. We recognize that such migration out of the injection aquifer may not formally constitute CO2 leakage up into potable shallow aquifers, if for example there is leak-off into intervening aquifers or multiple overlying low permeability formations that prevent further upward migration of the CO2. Finally, results show that a thin caprock or aquifer allows smaller events, but a much higher percentage of leakage in the upper aquifer. The elevate amount of leakage reduces drastically by assuming a multi-caprock, multi-aquifer system.

  20. Numerical investigation of methane and formation fluid leakage along the casing of a decommissioned shale gas well

    NASA Astrophysics Data System (ADS)

    Nowamooz, A.; Lemieux, J.-M.; Molson, J.; Therrien, R.

    2015-06-01

    Methane and brine leakage rates and associated time scales along the cemented casing of a hypothetical decommissioned shale gas well have been assessed with a multiphase flow and multicomponent numerical model. The conceptual model used for the simulations assumes that the target shale formation is 200 m thick, overlain by a 750 m thick caprock, which is in turn overlain by a 50 m thick surficial sand aquifer, the 1000 m geological sequence being intersected by a fully penetrating borehole. This succession of geological units is representative of the region targeted for shale gas exploration in the St. Lawrence Lowlands (Québec, Canada). The simulations aimed at assessing the impact of well casing cementation quality on methane and brine leakage at the base of a surficial aquifer. The leakage of fluids can subsequently lead to the contamination of groundwater resources and/or, in the case of methane migration to ground surface, to an increase in greenhouse gas emissions. The minimum reported surface casing vent flow (measured at ground level) for shale gas wells in Quebec (0.01 m3/d) is used as a reference to evaluate the impact of well casing cementation quality on methane and brine migration. The simulations suggest that an adequately cemented borehole (with a casing annulus permeability kc≤ 1 mD) can prevent methane and brine leakage over a time scale of up to 100 years. However, a poorly cemented borehole (kc≥ 10 mD) could yield methane leakage rates at the base of an aquifer ranging from 0.04 m3/d to more than 100 m3/d, depending on the permeability of the target shale gas formation after abandonment and on the quantity of mobile gas in the formation. These values are compatible with surface casing vent flows reported for shale gas wells in the St. Lawrence Lowlands (Quebec, Canada). The simulated travel time of methane from the target shale formation to the surficial aquifer is between a few months and 30 years, depending on cementation quality and

  1. Evaluation of particulate filtering respirators using inward leakage (IL) or total inward leakage (TIL) testing--Korean experience.

    PubMed

    Han, Don-Hee; Lee, Jinheon

    2005-10-01

    Korean certification regulation for particulate filtering respirators requires inward leakage (IL) or total inward leakage (TIL) testing according to European Standard EN 13274-1, and the standard levels of compliance are similar to those of the European Standard. This study was conducted to evaluate particulate filtering respirators being commercially used in the Korean market using an IL or TIL test and the validity of standard level in Korea. Three half masks and 10 filtering facepieces (two top class, four 1st class and four 2nd class)-a total of 13 brand name respirators-were selected for the test with panels of 10 subjects. Each subject was classified with nine facial dimension grid squares in accordance with face length and lip length. IL or TIL testing was conducted at the laboratory of the 3M Innovation Center in which the experimental instruments and systems were established in compliance with European standards. The testing procedure followed EN 13274-1 (2001). As expected, leakages of half masks were less than those of filtering facepieces and the latter were significantly different among brands. TILs of the 1st class filtering facepieces were found to be much more than those of the 2nd class and the result may cause a wearer to get confused when selecting a mask. The main route leakage for filtering facepieces may not be the filter medium but the face seal. Therefore, it is necessary to develop well-fitting filtering facepieces for Koreans. Because leakages were significantly different for different facial dimensions, a defined test panel for IL or TIL testing according to country or race should be developed. A more precise method to demonstrate fit, for example, fit testing such as in the US regulations, will be needed before IL or TIL testing or when selecting a respirator. Another finding implies that geometric mean of five exercises for IL or TIL may be better than arithmetic mean to establish a standard individual subject mean. PMID:16126767

  2. Leakage of radioactive particle systems from a synovial joint studied with a gamma camera. Its application to radiation synovectomy

    SciTech Connect

    Noble, J.; Jones, A.G.; Davies, M.A.; Sledge, C.B.; Kramer, R.I.; Livni, E.

    1983-03-01

    We have determined rates of leakage of radioactivity from a rabbit synovial pouch in vivo for a number of particle systems of varying sizes and differing resistance to degradation. The estimates were made using a gamma scintillation camera and without killing the test animals. The lowest leakage at twenty-four hours was seen with inert carbonized microspheres and the highest rates were seen with surface-labeled particles of biodegradable denatured human serum albumin and with erythrocytes. The carbonized microspheres had no adverse long-term effects on the health of the animals' articular cartilage. Clinical Relevance: Results obtained with inert particles indicate that reducing the biodegradability of the particle or increasing its diameter, or both, reduces radioactivity losses from the knee joint. Large (twenty-five-micrometer-diameter) microspheres of human serum albumin incorporating the radioactivity and carbonized microspheres are suggested as potential carriers of isotopes for human radiation synovectomy.

  3. Constraining Effects of Brine Leakage from Carbon Sequestration Sites

    NASA Astrophysics Data System (ADS)

    Wunsch, A.; Navarre-Sitchler, A. K.; McCray, J. E.

    2011-12-01

    Research has shown that pressure build up associated with injection of CO2 into a deep saline aquifer has the potential to promote brine leakage into overlying formations. In order to understand and quantify chemical changes in an underground source of drinking water (USDW) invaded by deep saline brines, we analyzed over 90,000 brine geochemical data entries from the NETL NATCARB brine database to identify potential brine constituents of concern. Using a variety of statistical methods and EPA regulatory levels or standards (RLS) we narrowed the list of brine constituents of potential concern to USDWs to TDS, thallium, chloride, sulfate and arsenic. Somewhat surprisingly, the distribution of reported pH had a fairly narrow distribution around a median value of 7.4, with over 78% of values complying with EPA recommended secondary standard for drinking water acidity. The pH distribution implies that unlike pure CO2 leakage, far-field brine leakage (i.e., brine not in contact with CO2) is not expected to bear a low-pH signature, thus suggesting use of other means of geochemical monitoring for brine leakage, such as electrical conductivity. Geochemical mixing models of brine and dilute water were used to constrain mixing ratios where RLS values are exceeded for the TDS, thallium and chloride. TDS and chloride exceed the EPA secondary standards at a brine/USDW mixing ratio of 0.012 and 0.459, respectively. The thallium maximum contaminant level (MCL) is exceeded at a brine/USDW mixing ratio of 0.3753, smaller than the chloride mixing ratio. However, sorption and/or desorption processes may alter thallium concentrations along a leakage pathway resulting in lower concentrations in the aquifer than predicted by simple mixing models. While leakage into USDWs has received considerable attention, brine contamination of groundwater used for irrigation of agricultural crops is also an important area of research. Our calculations suggest that almost all crops grown in the United

  4. Experimental Investigation of Elastomer Docking Seal Compression Set, Adhesion, and Leakage

    NASA Technical Reports Server (NTRS)

    Daniels, Christopher C.; Oswald, Jay J.; Bastrzyk, Marta B.; Smith, Ian; Dunlap, Patrick H., Jr.; Steinetz, Bruce M.

    2008-01-01

    A universal docking and berthing system is being developed by the National Aeronautics and Space Administration (NASA) to support all future space exploration missions to low-Earth orbit (LEO), to the Moon, and to Mars. An investigation of the compression set of two seals mated in a seal-on-seal configuration and the force required to separate the two seals after periods of mating was conducted. The leakage rates of seals made from two silicone elastomer compounds, S0383-70 and S0899-50, configured in seal-on-seal mating were quantified. The test specimens were sub-scale seals with representative cross-sections and a 12 inch outside diameter. The leakage rate of the seals manufactured from S0899-50 was higher than that of the seals made from S0383-70 by a factor of 1.8. Similarly, the adhesion of the 50 durometer elastomer was significantly higher than that of the 70 durometer compound. However, the compression set values of the S0899-50 material were observed to be significantly lower than those for the S0383-70.

  5. The measured energy impact of air leakage on frame wall systems

    SciTech Connect

    Bhattacharyya, S.

    1991-06-01

    Infiltration is customarily assumed to increase the heating and cooling load of a building by an amount equal to the mass flow rate of the infiltration times the enthalpy difference between the inside and outside air -- with the latent portion of the enthalpy difference sometimes neglected. An experimental and analytical investigation has been conducted on the actual energy impact of air leakage on frame wall systems. Calorimetric measurements conducted on a small test cell and on a well characterized stud-cavity wall specimen with measured amounts of air leakage introduced under a variety of controlled conditions and configurations show convincingly that infiltration can lead to a much smaller change in the energy load than is customarily calculated. The data also suggest that the phenomenon occurs in full-sized houses as well. Infiltration Heat Exchange Effectiveness (IHEE),{var epsilon}, is introduced as a measure of the effectiveness of a building in recovering'' heat otherwise lost (or gained) because of infiltration. Measurements show that {var epsilon} increases as: (a) flow rate decreases; (b) flow path length increases; and, (c) hole/crack size decreases.

  6. The measured energy impact of air leakage on frame wall systems. Final report

    SciTech Connect

    Bhattacharyya, S.

    1991-06-01

    Infiltration is customarily assumed to increase the heating and cooling load of a building by an amount equal to the mass flow rate of the infiltration times the enthalpy difference between the inside and outside air -- with the latent portion of the enthalpy difference sometimes neglected. An experimental and analytical investigation has been conducted on the actual energy impact of air leakage on frame wall systems. Calorimetric measurements conducted on a small test cell and on a well characterized stud-cavity wall specimen with measured amounts of air leakage introduced under a variety of controlled conditions and configurations show convincingly that infiltration can lead to a much smaller change in the energy load than is customarily calculated. The data also suggest that the phenomenon occurs in full-sized houses as well. Infiltration Heat Exchange Effectiveness (IHEE),{var_epsilon}, is introduced as a measure of the effectiveness of a building in ``recovering`` heat otherwise lost (or gained) because of infiltration. Measurements show that {var_epsilon} increases as: (a) flow rate decreases; (b) flow path length increases; and, (c) hole/crack size decreases.

  7. Classifying fractionated electrograms in human atrial fibrillation using monophasic action potentials and activation mapping: Evidence for localized drivers, rate acceleration, and nonlocal signal etiologies

    PubMed Central

    Narayan, Sanjiv M.; Wright, Matthew; Derval, Nicolas; Jadidi, Amir; Forclaz, Andrei; Nault, Isabelle; Miyazaki, Shinsuke; Sacher, Frédéric; Bordachar, Pierre; Clémenty, Jacques; Jaïs, Pierre; Haïssaguerre, Michel; Hocini, Mélèze

    2011-01-01

    BACKGROUND Complex fractionated electrograms (CFAEs) detected during substrate mapping for atrial fibrillation (AF) reflect etiologies that are difficult to separate. Without knowledge of local refractoriness and activation sequence, CFAEs may represent rapid localized activity, disorganized wave collisions, or far-field electrograms. OBJECTIVE The purpose of this study was to separate CFAE types in human AF, using monophasic action potentials (MAPs) to map local refractoriness in AF and multipolar catheters to map activation sequence. METHODS MAP and adjacent activation sequences at 124 biatrial sites were studied in 18 patients prior to AF ablation (age 57 ± 13 years, left atrial diameter 45 ± 8 mm). AF cycle length, bipolar voltage, and spectral dominant frequency were measured to characterize types of CFAE. RESULTS CFAE were observed at 91 sites, most of which showed discrete MAPs and (1) pansystolic local activity (8%); (2) CFAE after AF acceleration, often with MAP alternans (8%); or (3) nonlocal (far-field) signals (67%). A fourth CFAE pattern lacked discrete MAPs (17%), consistent with spatial disorganization. CFAE with discrete MAPs and pansystolic activation (consistent with rapid localized AF sites) had shorter cycle length (P <.05) and lower voltage (P <.05) and trended to have higher dominant frequency than other CFAE sites. Many CFAEs, particularly at the septa and coronary sinus, represented far-field signals. CONCLUSION CFAEs in human AF represent distinct functional types that may be separated using MAPs and activation sequence. In a minority of cases, CFAEs indicate localized rapid AF sites. The majority of CFAEs reflect far-field signals, AF acceleration, or disorganization. These results may help to interpret CFAE during AF substrate mapping. PMID:20955820

  8. Gas-path leakage seal for a turbine

    DOEpatents

    Bagepalli, Bharat Sampathkumaran; Aksit, Mahmut Faruk; Farrell, Thomas Raymond

    1999-01-01

    A gas-path leakage seal for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a turbine (such as combustor casing segments of a gas turbine). The seal includes a flexible and generally imperforate metal sheet assemblage having opposing first and second surfaces and two opposing raised edges extending a generally identical distance above and below the surfaces. A first cloth layer assemblage has a thickness generally equal to the previously-defined identical distance and is superimposed on the first surface between the raised edges. A second cloth layer assemblage is generally identical to the first cloth layer assemblage and is superimposed on the second surface between the raised edges.

  9. Mission analysis report for single-shell tank leakage mitigation

    SciTech Connect

    Cruse, J.M.

    1994-09-01

    This document provides an analysis of the leakage mitigation mission applicable to past and potential future leakage from the Hanford Site`s 149 single-shell high-level waste tanks. This mission is a part of the overall missions of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineers principles are being applied to this effort. Mission analysis supports early decision making by clearly defining program objectives. This documents identifies the initial conditions and acceptable final conditions, defines the programmatic and physical interfaces and constraints, estimates the resources to carry out the mission, and establishes measures of success. The results of the mission analysis provide a consistent basis for subsequent systems engineering work.

  10. New ac microammeter for leakage current measurement of biomedical equipment

    NASA Astrophysics Data System (ADS)

    Branca, F. P.; Del Prete, Z.; Marinozzi, F.

    1993-11-01

    A new inexpensive current probe for on-line leakage current measurement of biomedical devices in hospital environment is described. The prototype is designed to detect and measure leakage currents on the ground wire of the device's power cord so that its integrity can be monitored in real time. Realized with a sensing coil specially matched to a low-noise op amp, this probe adds only negligible impedance on the monitored ground lines. From this preliminary study about the device's metrological performances, a sensitivity of 10 nArms for a current range 1-500 μArms has emerged, together with a mean linearity error of 0.03% and a frequency response flat within 1% of gain from 50 to 2000 Hz.

  11. Leakage current measurements of a pixelated polycrystalline CVD diamond detector

    NASA Astrophysics Data System (ADS)

    Zain, R. M.; Maneuski, D.; O'Shea, V.; Bates, R.; Blue, A.; Cunnigham, L.; Stehl, C.; Berderman, E.; Rahim, R. A.

    2013-01-01

    Diamond has several desirable features when used as a material for radiation detection. With the invention of synthetic growth techniques, it has become feasible to look at developing diamond radiation detectors with reasonable surface areas. Polycrystalline diamond has been grown using a chemical vapour deposition (CVD) technique by the University of Augsburg and detector structures fabricated at the James Watt Nanofabrication Centre (JWNC) in the University of Glasgow in order to produce pixelated detector arrays. The anode and cathode contacts are realised by depositing gold to produce ohmic contacts. Measurements of I-V characteristics were performed to study the material uniformity. The bias voltage is stepped from -1000V to 1000V to investigate the variation of leakage current from pixel to pixel. Bulk leakage current is measured to be less than 1nA.

  12. A spectral-geophysical approach for detecting pipeline leakage

    NASA Astrophysics Data System (ADS)

    van der Meijde, M.; van der Werff, H. M. A.; Jansma, P. F.; van der Meer, F. D.; Groothuis, G. J.

    2009-02-01

    Leakage of hydrocarbon has a large economic and environmental impact. Traditional methods for investigating leakage and resulting pollution, such as drilling, are destructive, time consuming and expensive. Remote sensing is an alternative that is non-destructive and has been been tested extensively for exploration of onshore hydrocarbon reservoirs and detection of hydrocarbons at the Earth's surface. In this research, a leaking pipeline is investigated through field reflectance spectrometry and the findings are validated with traditional drilling and geophysical measurements. The measurements show a significant increase of vegetation anomalies on the pipeline with respect to areas further away. The observed anomalies are positively related to hydrocarbon pollution through chemical analysis of drillings. Subsurface geophysical measurements show a large correlation with observed surface vegetation stress, enhancing the identification of hydrocarbon-related vegetation stress through spectroscopy.

  13. Turbocharger with sliding piston, and having vanes and leakage dams

    DOEpatents

    Roberts, Quentin; Alnega, Ahmed

    2011-12-06

    A turbocharger having a sliding piston for regulating exhaust gas flow into the turbine wheel includes a set of first vanes mounted on a fixed first wall of the turbine nozzle and projecting axially toward an opposite second wall of the nozzle, and/or a set of second vanes mounted on the end of the piston and projecting in an opposite axial direction toward the first wall of the nozzle. For the/each set of vanes, there are leakage dams formed on the wall that is adjacent the vane tips when the piston is closed. The leakage dams are closely adjacent the vane tips and discourage exhaust gas from leaking in a generally radial direction past the vane tips as the piston just begins to open from its fully closed position.

  14. Gas-path leakage seal for a turbine

    DOEpatents

    Bagepalli, B.S.; Aksit, M.F.; Farrell, T.R.

    1999-08-10

    A gas-path leakage seal for generally sealing a gas-path leakage-gap between spaced-apart first and second members of a turbine (such as combustor casing segments of a gas turbine). The seal includes a flexible and generally imperforate metal sheet assemblage having opposing first and second surfaces and two opposing raised edges extending a generally identical distance above and below the surfaces. A first cloth layer assemblage has a thickness generally equal to the previously-defined identical distance and is superimposed on the first surface between the raised edges. A second cloth layer assemblage is generally identical to the first cloth layer assemblage and is superimposed on the second surface between the raised edges. 5 figs.

  15. Evaluation of leakage from a metal machining center using tracer gas methods: a case study.

    PubMed

    Heitbrink, W A; Earnest, G S; Mickelsen, R L; Mead, K R; D'Arcy, J B

    1999-01-01

    To evaluate the efficacy of engineering controls in reducing worker exposure to metalworking fluids, an evaluation of an enclosure for a machining center during face milling was performed. The enclosure was built around a vertical metal machining center with an attached ventilation system consisting of a 25-cm diameter duct, a fan, and an air-cleaning filter. The evaluation method included using sulfur hexafluoride (SF6) tracer gas to determine the ventilation system's flow rate and capture efficiency, a respirable aerosol monitor (RAM) to identify aerosol leak locations around the enclosure, and smoke tubes and a velometer to evaluate air movement around the outside of the enclosure. Results of the tracer gas evaluation indicated that the control system was approximately 98% efficient at capturing tracer gas released near the spindle of the machining center. This result was not significantly different from 100% efficiency (p = 0.2). The measured SF6 concentration when released directly into the duct had a relative standard deviation of 2.2%; whereas, when releasing SF6 at the spindle, the concentration had a significantly higher relative standard deviation of 7.8% (p = 0.016). This increased variability could be due to a cyclic leakage at a small gap between the upper and lower portion of the enclosure or due to cyclic stagnation. Leakage also was observed with smoke tubes, a velometer, and an aerosol photometer. The tool and fluid motion combined to induce a periodic airflow in and out of the enclosure. These results suggest that tracer gas methods could be used to evaluate enclosure efficiency. However, smoke tubes and aerosol instrumentation such as optical particle counters or aerosol photometers also need to be used to locate leakage from enclosures. PMID:10635544

  16. 42 CFR 84.204 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test; minimum requirements... Chemical Cartridge Respirators § 84.204 Exhalation valve leakage test; minimum requirements. (a) Dry... normal operating position. (b) Leakage between the valve and valve seat shall not exceed 30...

  17. 42 CFR 84.1150 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test; minimum requirements... Combination Gas Masks § 84.1150 Exhalation valve leakage test; minimum requirements. (a) Dry exhalation valves... operating position. (b) Leakage between the valve and valve seat shall not exceed 30 milliliters per minute....

  18. 42 CFR 84.182 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Exhalation valve leakage test; minimum requirements...-Powered Air-Purifying Particulate Respirators § 84.182 Exhalation valve leakage test; minimum requirements... height while in a normal operating position. (b) Leakage between the valve and valve seat shall...

  19. 42 CFR 84.204 - Exhalation valve leakage test; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Exhalation valve leakage test; minimum requirements... Chemical Cartridge Respirators § 84.204 Exhalation valve leakage test; minimum requirements. (a) Dry... normal operating position. (b) Leakage between the valve and valve seat shall not exceed 30...

  20. The use of tracers to assess leakage from the sequestration of CO2 in a depleted oil reservoir, New Mexico, USA

    SciTech Connect

    Wells, A.W.; Diehl, J.R.; Bromhal, G.S.; Strazisar, B.R.; Wilson, T.H.; White, C.M.

    2007-05-01

    Geological sequestration of CO2 in depleted oil reservoirs is a potentially useful strategy for greenhouse gas management and can be combined with enhanced oil recovery. Development of methods to estimate CO2 leakage rates is essential to assure that storage objectives are being met at sequestration facilities. Perfluorocarbon tracers (PFTs) were added as three 12 h slugs at about one week intervals during the injection of 2090 tons of CO2 into the West Pearl Queen (WPQ) depleted oil formation, sequestration pilot study site located in SE New Mexico. The CO2 was injected into the Permian Queen Formation. Leakage was monitored in soil–gas using a matrix of 40 capillary adsorbent tubes (CATs) left in the soil for periods ranging from days to months. The tracers, perfluoro-1,2-dimethylcyclohexane (PDCH), perfluorotrimethylcyclohexane (PTCH) and perfluorodimethylcyclobutane (PDCB), were analyzed using thermal desorption, and gas chromatography with electron capture detection. Monitoring was designed to look for immediate leakage, such as at the injection well bore and at nearby wells, and to develop the technology to estimate overall CO2 leak rates based on the use of PFTs. Tracers were detected in soil–gas at the monitoring sites 50 m from the injection well within days of injection. Tracers continued to escape over the following years. Leakage appears to have emanated from the vicinity of the injection well in a radial pattern to about 100 m and in directional patterns to 300 m. Leakage rates were estimated for the 3 tracers from each of the 4 sets of CATs in place following the start of CO2 injection. Leakage was fairly uniform during this period. As a first approximation, the CO2 leak rate was estimated at about 0.0085% of the total CO2 sequestered per annum.

  1. Tension-induced pore formation and leakage in adhering vesicles

    NASA Astrophysics Data System (ADS)

    Lenz, P.; Johnson, J. M.; Chan, Y.-H. M.; Boxer, S. G.

    2006-08-01

    The influence of inclusion-induced tension on pore formation is studied theoretically and experimentally. It is shown that fluorescently labeled lipids can enhance pore formation and induce leakage of adhering vesicles. These effects are more pronounced for smaller vesicles. The theoretical predictions are confirmed by experimental two-color fluorescent data. Finally, the influence of the pore formation dynamics on rupture processes of vesicles is analyzed yielding a new picture of the transition to bilayer disks.

  2. Alternative magnetic flux leakage modalities for pipeline inspection

    SciTech Connect

    Katragadda, G.; Lord, W.; Sun, Y.S.; Udpa, S.; Udpa, L.

    1996-05-01

    Increasing quality consciousness is placing higher demands on the accuracy and reliability of inspection systems used in defect detection and characterization. Nondestructive testing techniques often rely on using multi-transducer approaches to obtain greater defect sensitivity. This paper investigates the possibility of taking advantage of alternative modalities associated with the standard magnetic flux leakage tool to obtain additional defect information, while still using a single excitation source.

  3. Lymphangiography to Treat Postoperative Lymphatic Leakage: A Technical Review

    PubMed Central

    Lee, Edward Wolfgang; Ko, Heung Kyu; Park, Jihong; Kim, Soo Hwan; Sung, Kyu-Bo

    2014-01-01

    In addition to imaging the lymphatics and detecting various types of lymphatic leakage, lymphangiography is a therapeutic option for patients with chylothorax, chylous ascites, and lymphatic fistula. Percutaneous thoracic duct embolization, transabdominal catheterization of the cisterna chyli or thoracic duct, and subsequent embolization of the thoracic duct is an alternative to surgical ligation of the thoracic duct. In this pictorial review, we present the detailed technique, clinical applications, and complications of lymphangiography and thoracic duct embolization. PMID:25469083

  4. CO2 leakage risk in 3D heterogeneous formations

    NASA Astrophysics Data System (ADS)

    Hou, Z.; Murray, C. J.; Rockhold, M. L.

    2011-12-01

    In this study we use a stochastic sensitivity analysis framework to evaluate the impact of 3D spatial heterogeneity in permeability on CO2 leakage risk. The leakage is defined as the total mass of CO2 moving into the overburden through the caprock-overburden interface, in both gaseous and liquid (dissolved) phases. The entropy-based framework has the ability to quantify the uncertainty associated with the input parameters/factors in the form of prior pdfs (probability density functions). Effective sampling of the prior pdfs enables us to explore the parameter space and systematically evaluate the individual and combined effects of the factors/parameters of interest on CO2 leakage risk. The parameters that are considered in the study include: mean, variance, and horizontal to vertical spatial anisotropy ratio for caprock permeability, and those same parameters for reservoir permeability. Given the sampled spatial variogram parameters, multiple realizations of permeability fields were generated using GSLIB subroutines. For each permeability field, a numerical simulator STOMP (water-salt-CO2-energy operational mode) is used to simulate the CO2 migration within the reservoir and caprock up to 50 years after injection. Due to intensive computational demand, a scalable version simulator, eSTOMP, is run on the Jaguar supercomputer. We then perform statistical analyses and summarize the relationships between the parameters of interest (mean/variance/anisotropy ratio of caprock/reservoir permeability) and CO2 leakage ratio. We will also present the effects of those parameters on CO2 plume radius and reservoir injectivity.

  5. Limiting production rates in C-steel pipes. Removal of inhibitors/corrosion products by fatigue/yield action of liquid or gas/liquid

    SciTech Connect

    Soentvedt, T.

    1996-08-01

    The objective of this paper has been to form a link between the limiting production rates and the strength of the corrosion product formed on carbon steel. This paper has studied the available experimental data related to the failure of corrosion products with and without strengthening by inhibitors. Corrosion products in smooth pipes, bends and weldlike obstacles have been investigated. A model has been developed based on these observations which connects the strength of the corrosion product with the wall shear stress in both liquid and multiphase flow. Given the chemistry, temperature and metallurgy of the material the model allows the transformation from simple liquid tests to different flow conditions in the field. Thus limiting production rates in a field can be determined based on simple model tests. Relationships for the wall shear stress amplitudes, frequencies and mean values for various flow regimes have been developed. These relations are required in the model simulating the strength of the corrosion product. The paper shows why bends and weldlike obstacles constitute exposed areas. This study is the first of its kind. Thus the models developed lack detailed experimental verifications. The paper therefore briefly describes further work which has been initiated in order to verify the hypothesis formed.

  6. Surface Leakage Mechanisms in III-V Infrared Barrier Detectors

    NASA Astrophysics Data System (ADS)

    Sidor, D. E.; Savich, G. R.; Wicks, G. W.

    2016-09-01

    Infrared detector epitaxial structures employing unipolar barriers exhibit greatly reduced dark currents compared to simple pn-based structures. When correctly positioned within the structure, unipolar barriers are highly effective at blocking bulk dark current mechanisms. Unipolar barriers are also effective at suppressing surface leakage current in infrared detector structures employing absorbing layers that possess the same conductivity type in their bulk and at their surface. When an absorbing layer possesses opposite conductivity types in its bulk and at its surface, unipolar barriers are not solutions to surface leakage. This work reviews empirically determined surface band alignments of III-V semiconductor compounds and modeled surface band alignments of both gallium-free and gallium-containing type-II strained layer superlattice material systems. Surface band alignments are used to predict surface conductivity types in several detector structures, and the relationship between surface and bulk conductivity types in the absorbing layers of these structures is used as the basis for explaining observed surface leakage characteristics.

  7. Capillary leakage in inflammation. A study by vascular labeling.

    PubMed Central

    Joris, I.; Cuénoud, H. F.; Doern, G. V.; Underwood, J. M.; Majno, G.

    1990-01-01

    The local injection of pure inflammatory mediators induces venular leakage. To test the effect of endogenous mediators from dying tissue on vascular leakage, the authors devised an experimental model simulating an infarct, whereby living vessels would be exposed to fragments of organs undergoing aseptic necrosis. Tissues from donor rats were implanted aseptically in the cremasteric sac. Control rats were implanted with materials deemed to be as close as possible to nonirritating: boiled tissues and spheres of Teflon or glass. At different points the rats were injected intravenously with carbon black and killed an hour later. Whole cremaster mounts showed that vascular labeling was strictly venular up to 8 hours, mixed with capillary labeling between 12 and 24 hours, and mainly or exclusively capillary at 48 hours. Histology showed an acute inflammatory infiltrate in the labeled areas. A similar but weaker labeling pattern accompanied by milder inflammation was seen in controls. These results indicate that the vascular leakage in aseptic inflammation is biphasic, first venular, then capillary; and that the capillary phase is induced by the inflammatory reaction itself, possibly through a form of diffuse angiogenesis. Images Figure 2 Figure 3 Figure 5 Figure 6 PMID:2260625

  8. A new approach for stabilizing labyrinth seal leakage

    NASA Astrophysics Data System (ADS)

    Rhode, D. L.; Guidry, M. J.

    1993-04-01

    A parametric study of geometrical effects on labyrinth seal leakage resistance was conducted using a recently developed Navier-Stokes finite difference code. Previously unavailable design data in terms of an effective cavity friction factor was obtained. Also, a new leakage stability design approach was found, and the parametric study data was used accordingly in designing a seal with nonuniform cavities for the new high-pressure oxygen turbo-pump of the space shuttle main engine. The leakage resistance showed significantly greater stability over an extremely wide range of rotor axial position. Further, an enhanced basic understanding of the effect of sharp knife corners on cavity friction factor is obtained from contours of intense turbulence generation. The location of these contours shows that it is the sharp streamline curvature at high velocity slightly upstream of the vena contracta which provides the primary intense turbulent friction. This is a departure from the previous belief that the large turbulent stresses near the edge of the vena contracta are primarily responsible. This finding is expected to be helpful in designing more advanced knife configurations.

  9. Management of excluded segmental bile duct leakage following liver resection

    PubMed Central

    Honoré, Charles; Vibert, Eric; Hoti, Emir; Azoulay, Daniel; Adam, René; Castaing, Denis

    2009-01-01

    Background: Postoperative bile leak secondary to a fistula is a known complication of hepatic surgery. Four different biliary fistula sub-types have been described: type A refers to minor leakage from the bile duct stump; type B to major leakage caused by insufficient closure of the bile duct stump; type C to major leakage caused by injury to the bile duct, and type D (the rarest) to the division and exclusion of a bile duct. This complication results from functional liver parenchyma in which bile drainage is excluded from the main duct. Methods: A retrospective review of the database for 163 patients diagnosed with post-hepatic surgery bile leak from April 1992 to June 2007 was performed. Results: Three patients were found to have type D biliary fistula, with durations of 3–21 months. The bile leak developed after a right hepatectomy in two patients and a right hepatectomy extending to segment IV in one patient. All three patients were rescheduled for surgical exploration, following failure of medical treatment. The procedure consisted of repeat resection of the independent liver parenchyma containing the fistula. One patient developed a postoperative leak from a hepaticojejunal anastomosis (treated conservatively) and the other two patients had an uneventful recovery. No recurrence of bile leak was encountered during their follow-up. Conclusions: Our experience indicates that conservative treatment is deceptive and not efficacious. For this condition, surgical intervention is the treatment of choice because it is very effective and is associated with a low morbidity. PMID:19718366

  10. Air Leakage and Air Transfer Between Garage and Living Space

    SciTech Connect

    Rudd, Armin

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  11. Analysis of main steam isolation valve leakage in design basis accidents using MELCOR 1.8.6 and RADTRAD.

    SciTech Connect

    Salay, Michael; Kalinich, Donald A.; Gauntt, Randall O.; Radel, Tracy E.

    2008-10-01

    Analyses were performed using MELCOR and RADTRAD to investigate main steam isolation valve (MSIV) leakage behavior under design basis accident (DBA) loss-of-coolant (LOCA) conditions that are presumed to have led to a significant core melt accident. Dose to the control room, site boundary and LPZ are examined using both approaches described in current regulatory guidelines as well as analyses based on best estimate source term and system response. At issue is the current practice of using containment airborne aerosol concentrations as a surrogate for the in-vessel aerosol concentration that exists in the near vicinity of the MSIVs. This study finds current practice using the AST-based containment aerosol concentrations for assessing MSIV leakage is non-conservative and conceptually in error. A methodology is proposed that scales the containment aerosol concentration to the expected vessel concentration in order to preserve the simplified use of the AST in assessing containment performance under assumed DBA conditions. This correction is required during the first two hours of the accident while the gap and early in-vessel source terms are present. It is general practice to assume that at {approx}2hrs, recovery actions to reflood the core will have been successful and that further core damage can be avoided. The analyses performed in this study determine that, after two hours, assuming vessel reflooding has taken place, the containment aerosol concentration can then conservatively be used as the effective source to the leaking MSIV's. Recommendations are provided concerning typical aerosol removal coefficients that can be used in the RADTRAD code to predict source attenuation in the steam lines, and on robust methods of predicting MSIV leakage flows based on measured MSIV leakage performance.

  12. A Clinical Parameters-Based Model Predicts Anastomotic Leakage After a Laparoscopic Total Mesorectal Excision: A Large Study With Data From China.

    PubMed

    Hu, Xiang; Cheng, Yong

    2015-07-01

    Anastomotic leakage after colorectal surgery is a major and life-threatening complication that occurs more frequently than expected. Intraoperative judgment in predicting potential leakage has shown extremely low sensitivity and specificity. The lack of a model for predicting anastomotic leakage might explain this insufficient judgment. We aimed to propose a clinical parameters-based model to predict anastomotic leakage after laparoscopic total mesorectal excision (TME).This study was a retrospective analysis of a prospectively designed colorectal cancer dataset. In total, 1968 patients with a laparoscopic TME were enrolled from November 1, 2010, to March 20, 2014. The independent risk factors for anastomotic leakage were identified, from which the parameters-based model for leakage was developed.Anastomotic leakage was noted in 63 patients (3.2%). Male sex, a low level of anastomosis, intraoperative blood loss, diabetes, the duration time of the surgery, and low temperature were significantly associated by the bivariate analysis and the Cochran-Mantel-Haenszel test with an increased risk. From these factors, the logistic regression model identified the following 4 independent predictors: male sex (risk ratio [RR] = 1.85, 95% confidence interval [CI]: 1.13-4.87), diabetes (RR = 2.08, 95% CI: 1.19-5.8), a lower anastomosis level (RR = 3.41, 95% CI: 1.17-6.71), and a high volume of blood loss (RR = 1.03, 95% CI: 1.01-1.05). The locally weighted scatterplot smoothing regression showed an anastomosis within 5 cm from the anus and intraoperative blood loss of >100 mL as the cutoff values for a significantly increased risk of leakage. Based on these independent factors, a parameters-based model was established by the regression coefficients. The high and low-risk groups were classified according to scores of 3-5 and 0-2, with leakage rates of 8.57% and 1.66%, respectively (P < 0.001).This parameters-based model could predict the risk of anastomotic leakage following

  13. Dosimetry of a thyroid uptake detected in seed migration survey following a patient's iodine-125 prostate implant and in vitro measurements of intentional seed leakages

    SciTech Connect

    Chen Qinsheng; Russell, John L. Jr.; Macklis, Roger R.; Weinhous, Martin S.; Blair, Henry F.

    2006-07-15

    leakage rates were observed. Considering the body fluid is more complex than saline, the in vivo leakage half-life, in case a source leak is encountered, may vary significantly from what is presented in this paper due to chemical reactions. In vivo measurements thus may produce a more accurate estimation of leakage half-life and thyroid uptake dose.

  14. SENSITIVITY OF THE HOUSE PRESSURE TEST FOR DUCT LEAKAGE TO VARIATIONS IN THE DISTRIBUTION OF AIR LEAKAGE IN THE HOUSE ENVELOPE

    SciTech Connect

    ANDREWS,J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  15. Sensitivity of the house pressure test for duct leakage to variations in the distribution of air leakage in the house envelope

    SciTech Connect

    Andrews, J.W.

    1998-12-01

    The house pressure test for air leakage in ducts calculates the signed difference between the supply and return leakage from the response of the air pressure in the house to operation of the system fan. The currently accepted version of this calculation was based on particular assumptions about how the house envelope leakage is distributed between the walls, ceiling, and floor. This report generalizes the equation to account for an arbitrary distribution of envelope leakage. It concludes that the currently accepted equation is usually accurate to within {+-}5%, but in a small proportion of cases the results may diverge by 50% or more.

  16. Leakage detection of Marcellus Shale natural gas at an Upper Devonian gas monitoring well: a 3-d numerical modeling approach.

    PubMed

    Zhang, Liwei; Anderson, Nicole; Dilmore, Robert; Soeder, Daniel J; Bromhal, Grant

    2014-09-16

    Potential natural gas leakage into shallow, overlying formations and aquifers from Marcellus Shale gas drilling operations is a public concern. However, before natural gas could reach underground sources of drinking water (USDW), it must pass through several geologic formations. Tracer and pressure monitoring in formations overlying the Marcellus could help detect natural gas leakage at hydraulic fracturing sites before it reaches USDW. In this study, a numerical simulation code (TOUGH 2) was used to investigate the potential for detecting leaking natural gas in such an overlying geologic formation. The modeled zone was based on a gas field in Greene County, Pennsylvania, undergoing production activities. The model assumed, hypothetically, that methane (CH4), the primary component of natural gas, with some tracer, was leaking around an existing well between the Marcellus Shale and the shallower and lower-pressure Bradford Formation. The leaky well was located 170 m away from a monitoring well, in the Bradford Formation. A simulation study was performed to determine how quickly the tracer monitoring could detect a leak of a known size. Using some typical parameters for the Bradford Formation, model results showed that a detectable tracer volume fraction of 2.0 × 10(-15) would be noted at the monitoring well in 9.8 years. The most rapid detection of tracer for the leak rates simulated was 81 days, but this scenario required that the leakage release point was at the same depth as the perforation zone of the monitoring well and the zones above and below the perforation zone had low permeability, which created a preferred tracer migration pathway along the perforation zone. Sensitivity analysis indicated that the time needed to detect CH4 leakage at the monitoring well was very sensitive to changes in the thickness of the high-permeability zone, CH4 leaking rate, and production rate of the monitoring well. PMID:25144442

  17. Low-dose-rate high-let radiation cytogenetic effects on mice in vivo as model of space radiation action on mammalian

    NASA Astrophysics Data System (ADS)

    Sorokina, Svetlana; Zaichkina, Svetlana; Rozanova, Olga; Aptikaeva, Gella; Romanchenko, Sergei; Smirnova, Helene; Dyukina, Alsu; Peleshko, Vladimir

    At present time little is known concerning the biological effects of low-dose-rate high-LET radiation exposure in space. The currently available experimental data on the biological effect of low doses of chronic radiation with high-LET values, which occur under the conditions of aircraft and space flights, have been primarily obtained in the examinations of pilots and astronauts after flights. Another way of obtaining this kind of evidence is the simulation of irradiation conditions during aircraft and space flights on high-energy accelerators and the conduction of large-scale experiments on animals under these conditions on Earth. In the present work, we investigated the cytogenetic effects of low-dose-rate high-LET radiation in the dose ranges of 0.2-30 cGy (1 cGy/day) and 0.5-16 cGy (0.43 cGy/day) in the radiation field behind the concrete shield of the Serpukhov accelerator of 70 GeV protons that simulates the spectral and component composition of radiation fields formed in the conditions of high-altitude flights on SHK mice in vivo. The dose dependence, adaptive response (AR) and the growth of solid tumor were examined. For induction of AR, two groups of mice were exposed to adapting doses of 0.2-30 cGy and the doses of 0.5-16 cGy of high-LET radiation. For comparison, third group of mice from unirradiated males was chronically irradiated with X-rays at adapting doses of 10 cGy (1 cGy/day). After a day, the mice of all groups were exposed to a challenging dose of 1.5 Gy of X-rays (1 Gy/min). After 28 h, the animals of all groups were killed by the method of cervical dislocation. Bone marrow specimens for calculating micronuclei (MN) in polychromatic erythrocytes (PCE) were prepared by a conventional method with minor modifications. The influence of adapting dose of 16 cGy on the growth of solid tumor of Ehrlich ascite carcinoma was estimated by measuring the size of the tumor at different times after the inoculation of ascitic cells s.c. into the femur. It was

  18. Action Learning.

    ERIC Educational Resources Information Center

    1996

    These four papers were presented at a symposium on action learning moderated by Lex Dilworth at the 1996 conference of the Academy of Human Resource Development. "Developing an Infrastructure for Individual and Organizational Change: Transfer of Learning from an Action Reflection Learning (ARL) Program" (ARL Inquiry) reports findings from a study…

  19. Eddy covariance observations of surface leakage during shallow subsurface CO2 releases

    SciTech Connect

    Lewicki, J. L.; Hilley, G.E.; Fischer, M.L.; Pan, L.; Oldenburg, C.M.; Dobeck, L.; Spangler, L.

    2009-04-01

    We tested the ability of eddy covariance (EC) to detect, locate, and quantify surface CO{sub 2} flux leakage signals within a background ecosystem. For 10 days starting on 07/09/2007, and for seven days starting on 08/03/2007, 0.1 (Release 1) and 0.3 (Release 2) t CO{sub 2}d{sup -1}, respectively, were released from a horizontal well {approx}100 m in length and {approx}2.5 m in depth located in an agricultural field in Bozeman, MT. An EC station measured net CO{sub 2} flux (F{sub c}) from 06/08/2006 to 09/04/2006 (mean and standard deviation = -12.4 and 28.1 g m{sup -2} d{sup -1}, respectively) and from 05/28/2007 to 09/04/2007 (mean and standard deviation = -12.0 and 28.1 g m{sup -2} d{sup -1}, respectively). The Release 2 leakage signal was visible in the F{sub c} time series, whereas the Release 1 signal was difficult to detect within variability of ecosystem fluxes. To improve detection ability, we calculated residual fluxes (F{sub cr}) by subtracting fluxes corresponding to a model for net ecosystem exchange from F{sub c}. F{sub cr} had reduced variability and lacked the negative bias seen in corresponding F{sub c} distributions. Plotting the upper 90th percentile F{sub cr} versus time enhanced the Release 2 leakage signal. However, values measured during Release 1 fell within the variability assumed to be related to unmodeled natural processes. F{sub cr} measurements and corresponding footprint functions were inverted using a least-squares approach to infer the spatial distribution of surface CO{sub 2} fluxes during Release 2. When combined with flux source area evaluation, inversion results roughly located the CO{sub 2} leak, while resolution was insufficient to quantify leakage rate.

  20. Fault-tolerant quantum computation for singlet-triplet qubits with leakage errors

    NASA Astrophysics Data System (ADS)

    Mehl, Sebastian; Bluhm, Hendrik; DiVincenzo, David P.

    2015-02-01

    We describe and analyze leakage errors of singlet-triplet qubits. Even though leakage errors are a natural problem for spin qubits encoded using quantum dot arrays, they have obtained little attention in previous studies. We describe the realization of leakage correction protocols that can be implemented together with the quantum error correction protocol of the surface code. Furthermore we construct explicit leakage reduction units that need, in the ideal setup, as few as three manipulation steps. Our study shows that leakage errors can be corrected without the need of measurements and at the cost of only a few additional ancilla qubits and gate operations compared to standard quantum error correction codes.