Sample records for activation instrumental analysis

  1. Neutron activation analysis: trends in developments and applications

    NASA Astrophysics Data System (ADS)

    de Goeij, J. J.; Bode, P.

    1995-03-01

    New developments in instrumentation for, and methodology of, Instrumental Neutron Activation Analysis (INAA) may lead to new niches for this method of elemental analysis. This paper describes the possibilities of advanced detectors, automated irradiation and counting stations, and very large sample analysis. An overview is given of some typical new fields of application.

  2. Instrumental Neutron Activation Analysis and Multivariate Statistics for Pottery Provenance

    NASA Astrophysics Data System (ADS)

    Glascock, M. D.; Neff, H.; Vaughn, K. J.

    2004-06-01

    The application of instrumental neutron activation analysis and multivariate statistics to archaeological studies of ceramics and clays is described. A small pottery data set from the Nasca culture in southern Peru is presented for illustration.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year 1990. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis. The Chemical Analysis Group uses wet-chemical and instrumental methods for elemental, compositional, and isotopic analyses of solid, liquid, and gaseous samples and provides specialized analytical services. The Instrumental Analysis Group uses nuclear counting techniques in radiochemical analyses over a wide range of sample types from low-level environmental samples to samples of high radioactivity. The Organic Analysis Group uses amore » number of complementary techniques to separate and to quantitatively and qualitatively analyze complex organic mixtures and compounds at the trace level, including synthetic fuels, toxic substances, fossil-fuel residues and emissions, pollutants, biologically active compounds, pesticides, and drugs. The Environmental Analysis Group performs analyses of inorganic environmental and hazardous waste and coal samples.« less

  4. Short version of the "instrument for assessment of stress in nursing students" in the Brazilian reality.

    PubMed

    Costa, Ana Lúcia Siqueira; Silva, Rodrigo Marques da; Mussi, Fernanda Carneiro; Serrano, Patrícia Maria; Graziano, Eliane da Silva; Batista, Karla de Melo

    2018-01-08

    validate a short version of the Instrument for assessment of stress in nursing students in the Brazilian reality. Methodological study conducted with 1047 nursing students from five Brazilian institutions, who answered the 30 items initially distributed in eight domains. Data were analyzed in the R Statistical Package and in the latent variable analysis, using exploratory and confirmatory factor analyses, Cronbach's alpha and item-total correlation. The short version of the instrument had 19 items distributed into four domains: Environment, Professional Training, Theoretical Activities and Performance of Practical Activities. The confirmatory analysis showed absolute and parsimony fit to the proposed model with satisfactory residual levels. Alpha values ​​per factor ranged from 0.736 (Environment) to 0.842 (Performance of Practical Activities). The short version of the instrument has construct validity and reliability for application to Brazilian nursing undergraduates at any stage of the course.

  5. A field instrument for quantitative determination of beryllium by activation analysis

    USGS Publications Warehouse

    Vaughn, William W.; Wilson, E.E.; Ohm, J.M.

    1960-01-01

    A low-cost instrument has been developed for quantitative determinations of beryllium in the field by activation analysis. The instrument makes use of the gamma-neutron reaction between gammas emitted by an artificially radioactive source (Sb124) and beryllium as it occurs in nature. The instrument and power source are mounted in a panel-type vehicle. Samples are prepared by hand-crushing the rock to approximately ?-inch mesh size and smaller. Sample volumes are kept constant by means of a standard measuring cup. Instrument calibration, made by using standards of known BeO content, indicates the analyses are reproducible and accurate to within ? 0.25 percent BeO in the range from 1 to 20 percent BeO with a sample counting time of 5 minutes. Sensitivity of the instrument maybe increased somewhat by increasing the source size, the sample size, or by enlarging the cross-sectional area of the neutron-sensitive phosphor normal to the neutron flux.

  6. Cultural adaptation of an instrument to assess physical fitness in cardiac patients.

    PubMed

    Domingues, Gabriela de Barros Leite; Gallani, Maria Cecília; Gobatto, Claudio Alexandre; Miura, Cinthya Tamie Passos; Rodrigues, Roberta Cunha Matheus; Myers, Jonathan

    2011-04-01

    To validate the content and to evaluate the reliability of the Veterans Specific Activity Questionnaire instrument, culturally adapted for use in the Brazilian population of cardiac patients. The instrument was translated and back-translated and subsequently analyzed by a committee of judges to evaluate its semantic-idiomatic and cultural equivalences. Physical activities were replaced when indicated in the instrument, but uncommon in the daily life of the target population. Another committee of specialists analyzed the metabolic equivalence of replaced activities. The proportion of agreement of evaluation of the judges was quantified by the Content Validity Index. The pre-test was performed in two stages (n1 and n2=15). Reliability was assessed using the test-retest (interval of 7-15 days, n = 50). In the evaluation of semantic-idiomatic and cultural equivalences, items with a Content Validity Index < 1 were reviewed until consensus among the judges was obtained. The second committee found 100% of agreement in the analysis of metabolic equivalence between original and replaced activities. Test-retest analysis indicated a Kappa coefficient of agreement (k = 0.86; (p<0.001), suggesting temporal stability of the instrument. The Brazilian version of the Veterans Specific Activity Questionnaire showed evidence of reliability, according to the temporal stability criterion and adequate cultural content.

  7. Instrumental activation analysis of coal and fly ash with thermal and epithermal neutrons and short-lived nuclides

    USGS Publications Warehouse

    Steinnes, E.; Rowe, J.J.

    1976-01-01

    Instrumental neutron activation analysis is applied to the determination of about 25 elements in coals and fly ash by means of nuclides with half-lives of less than 48 h ; thermal and epithermal irradiations are used. The results indicate that epithermal activation is preferable for twelve of the elements (Ga, As, Br, Sr, In, Cs, Ba, La, Sm, Ho, W and U). Data for SRM 1632 (coal) and SRM 1633 (fly ash) compare favorably with the results obtained by other investigators. ?? 1976.

  8. 30 CFR 280.30 - What activities will not require environmental analysis?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... additional environmental analysis. The types of activities include: (a) Gravity and magnetometric... oceanographic observations and measurements, including the setting of instruments; (g) Sampling by box core or...

  9. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Sierra, O.; Parrado, G.; Cañón, Y.; Porras, A.; Alonso, D.; Herrera, D. C.; Peña, M.; Orozco, J.

    2016-07-01

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in sample density between samples and standards.

  10. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    PubMed

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (<0.1 ms) followed by several lower force (30 to 100 N), longer duration impulses (1 to 5 ms). The force profile was highly reproducible in terms of the peak impulse forces delivered to the beam structure (<8% variance). Spectrum analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving point impedance at the resonant frequency were high (67%) compared with the transfer impedance measurements obtained with the electronic PCB impact hammer, which had a more uniform force spectrum and was more repeatable (<10% variation). The addition of a preload-control frame to the Activator Adjusting Instrument improved the characteristics of the force frequency spectrum and repeatability of the driving point impedance measurements. These findings indicate that the Activator Adjusting Instrument combined with an integral load cell and accelerometer was able to obtain an accurate description of a steel beam with readily identifiable geometric and dynamic mechanical properties. These findings support the rationale for using the device to assess the dynamic mechanical behavior of the vertebral column. Such information would be useful for SMT and may ultimately be used to evaluate the [corrected] biomechanical effectiveness of various manipulative, surgical, and rehabilitative spinal procedures.

  11. Reinforcement and substitution in humans: a multiple-response analysis1

    PubMed Central

    Bernstein, Daniel J.; Ebbesen, Ebbe B.

    1978-01-01

    Three adult human subjects engaged in activities such as reading, sewing, artwork, and candlemaking while living alone in a laboratory apartment 24 hours per day for several weeks. After a baseline period in which the activities were fully available, access to a particular activity (contingent response) was made dependent on engaging in another less-preferred activity (instrumental response). The contingencies produced substantial increases in instrumental responding, and responding decreased toward baseline levels when the dependency was removed. Under the contingent conditions, time earned for the concurrent activity was always less than the baseline level. To determine the contribution of this reduction to the instrumental increase, access to the contingent activity was restricted in the absence of any dependency. The results indicated that increases among responses that filled the newly available time could be selective, e.g., artwork increased when reading was restricted but candlemaking did not. It was concluded that the reductions in the contingent response that accompany contingencies usually do not exclusively determine instrumental increases, but selective increases can contribute to the increase in time devoted to the instrumental response. PMID:16812105

  12. The PROactive instruments to measure physical activity in patients with chronic obstructive pulmonary disease

    PubMed Central

    Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A.; Hopkinson, Nicholas S.; Polkey, Michael I.; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I.; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A.; Karlsson, Niklas

    2015-01-01

    No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD. Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts. 236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled “amount” and “difficulty”. After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test–retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity. Daily and clinical visit “PROactive physical activity in COPD” instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. PMID:26022965

  13. The PROactive instruments to measure physical activity in patients with chronic obstructive pulmonary disease.

    PubMed

    Gimeno-Santos, Elena; Raste, Yogini; Demeyer, Heleen; Louvaris, Zafeiris; de Jong, Corina; Rabinovich, Roberto A; Hopkinson, Nicholas S; Polkey, Michael I; Vogiatzis, Ioannis; Tabberer, Maggie; Dobbels, Fabienne; Ivanoff, Nathalie; de Boer, Willem I; van der Molen, Thys; Kulich, Karoly; Serra, Ignasi; Basagaña, Xavier; Troosters, Thierry; Puhan, Milo A; Karlsson, Niklas; Garcia-Aymerich, Judith

    2015-10-01

    No current patient-centred instrument captures all dimensions of physical activity in chronic obstructive pulmonary disease (COPD). Our objective was item reduction and initial validation of two instruments to measure physical activity in COPD.Physical activity was assessed in a 6-week, randomised, two-way cross-over, multicentre study using PROactive draft questionnaires (daily and clinical visit versions) and two activity monitors. Item reduction followed an iterative process including classical and Rasch model analyses, and input from patients and clinical experts.236 COPD patients from five European centres were included. Results indicated the concept of physical activity in COPD had two domains, labelled "amount" and "difficulty". After item reduction, the daily PROactive instrument comprised nine items and the clinical visit contained 14. Both demonstrated good model fit (person separation index >0.7). Confirmatory factor analysis supported the bidimensional structure. Both instruments had good internal consistency (Cronbach's α>0.8), test-retest reliability (intraclass correlation coefficient ≥0.9) and exhibited moderate-to-high correlations (r>0.6) with related constructs and very low correlations (r<0.3) with unrelated constructs, providing evidence for construct validity.Daily and clinical visit "PROactive physical activity in COPD" instruments are hybrid tools combining a short patient-reported outcome questionnaire and two activity monitor variables which provide simple, valid and reliable measures of physical activity in COPD patients. Copyright ©ERS 2015.

  14. Determination of twenty-nine elements in eight argonne premium coal samples by instrumental neutron activation analysis

    USGS Publications Warehouse

    Palmer, C.A.

    1990-01-01

    Twenty-nine elements have been determined in triplicate splits of the eight Argonne National Laboratory Premium Coal Samples by instrumental neutron activtaion analysis. Data for control samples NBS 1633 (fly ash) and NBS 1632b are also reported. The factors that could lead to errors in analysis for these samples, such as spectral overlaps, low sensitivity, and interfering nuclear reactions, are discussed.

  15. EASY-An Instrument for Surveillance of Physical Activity in Youth.

    PubMed

    Pate, Russell R; McIver, Kerry; Dowda, Marsha; Schenkelberg, Michaela A; Beets, Michael; DiStefano, Christine

    2018-01-23

    Physical activity (PA) promotion among youth is a public health priority and there is a need for robust surveillance systems to help support such initiatives. Existing youth PA self-report instruments that are used for surveillance lack information regarding the types and contexts of activity. Further, these instruments have limited validity with accelerometry. The purpose of the present study was to develop a self-report instrument, with sound psychometric properties, for monitoring compliance with PA guidelines in youth. In focus groups, 162 middle school students identified 30 forms of PA that are highly prevalent in that age group. We incorporated these activities into three preliminary forms of a self-report instrument. An independent sample of middle school students (n = 537) was randomly assigned to complete one of the three preliminary versions of the instrument. Rasch analysis was applied to the responses to the three formats, and a yes/no plus frequency format emerged as the preferred method. A third sample of 342 middle school students then completed the yes/no plus frequency instrument twice following a seven-day period during which they wore an accelerometer. Using both Rasch analysis and traditional correlational methods, validity and reliability of a 14-item instrument were established. Data were collected during 2012 - 2015. Spearman correlation coefficient for the association between the cumulative score for the 14 items and minutes per day of accelerometry-derived moderate-to-vigorous physical activity (MVPA) was 0.33 (95% CI 0.22, 0.43; p<.001). Sensitivity and specificity of the 14-item instrument was 0.90 and 0.44, respectively. The study produced a PA self-report instrument for youth that was found to be reliable (r=0.91), valid versus accelerometry (r=0.33), and acceptably specific and sensitive in detecting compliance with PA guidelines.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

  16. Characterization of HPGe gamma spectrometric detectors systems for Instrumental Neutron Activation Analysis (INAA) at the Colombian Geological Survey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sierra, O., E-mail: osierra@sgc.gov.co; Parrado, G., E-mail: gparrado@sgc.gov.co; Cañón, Y.

    This paper presents the progress made by the Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey (SGC in its Spanish acronym), towards the characterization of its gamma spectrometric systems for Instrumental Neutron Activation Analysis (INAA), with the aim of introducing corrections to the measurements by variations in sample geometry. Characterization includes the empirical determination of the interaction point of gamma radiation inside the Germanium crystal, through the application of a linear model and the use of a fast Monte Carlo N-Particle (MCNP) software to estimate correction factors for differences in counting efficiency that arise from variations in samplemore » density between samples and standards.« less

  17. [Development of an instrument to measure psychosocial determinants of physical activity behavior among coronary heart disease patients].

    PubMed

    Mendez, Roberto Della Rosa; Rodrigues, Roberta Cunha Matheus; Cornélio, Marilia Estevam; Gallani, Maria Cecília Bueno Jayme; Godin, Gaston

    2010-09-01

    The aim of this study was to report the development and the analysis of content validity and reliability of the Psychosocial Determinants of Physical Activity among Coronary Heart Disease Patients Questionnaire, based on an extension of the Theory of Planned Behavior. In the content validity step, three experts evaluated the instrument which was, afterwards, pre-tested with five subjects in order to obtain a conceptually appropriate and easily understood instrument. Fifty-one patients participated in the evaluation of internal consistency of the reviewed instrument. Cronbach's alpha coefficients above 0.75 were observed for the constructs: Intention, Attitude, Subjective Norm, Self-efficacy and Habit. The new instrument demonstrated acceptable evidence of content validity and reliability.

  18. Aerobic Exercise Sustains Performance of Instrumental Activities of Daily Living in Early-Stage Alzheimer Disease.

    PubMed

    Vidoni, Eric D; Perales, Jaime; Alshehri, Mohammed; Giles, Abdul-Mannaan; Siengsukon, Catherine F; Burns, Jeffrey M

    2017-12-28

    Individuals with Alzheimer disease (AD) experience progressive loss of independence-performing activities of daily living. Identifying interventions to support independence and reduce the economic and psychosocial burden of caregiving for individuals with AD is imperative. The purpose of this analysis was to examine functional disability and caregiver time in individuals with early-stage AD. This was a secondary analysis of a randomized controlled trial of 26 weeks of aerobic exercise (AEx) versus stretching and toning (ST). We measured functional dependence using the Disability Assessment for Dementia, informal caregiver time required using the Resources Utilization in Dementia Lite, and cognition using a standard cognitive battery. We saw a stable function in the AEx group compared with a significant decline in the ST group (4%; F = 4.2, P = .04). This was especially evident in more complex, instrumental activities of daily living, with individuals in the AEx group increasing 1% compared with an 8% loss in the ST group over 26 weeks (F = 8.3, P = .006). Change in memory was a significant predictor of declining instrumental activities of daily living performance (r = 0.28, 95% confidence interval = 0.08 ∞, P = .01). Informal caregiver time was not different between the AEx and ST groups. Our analysis extends recent work by revealing specific benefits for instrumental activities of daily living for individuals in the early stages of AD and supports the value of exercise for individuals with cognitive impairment.

  19. Edward's sword? - A non-destructive study of a medieval king's sword

    NASA Astrophysics Data System (ADS)

    Segebade, Chr.

    2013-04-01

    Non-destructive and instrumental methods including photon activation analysis were applied in an examination of an ancient sword. It was tried to find indication of forgery or, if authentic, any later processing and alteration. Metal components of the hilt and the blade were analysed by instrumental photon activation. Non-destructive metallurgical studies (hardness measurements, microscopic microstructure analysis) are briefly described, too. The results of these investigations did not yield indication of non-authenticity. This stood in agreement with the results of stylistic and scientific studies by weapon experts.

  20. Edward's sword? - A non-destructive study of a medieval king's sword

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Segebade, Chr.

    2013-04-19

    Non-destructive and instrumental methods including photon activation analysis were applied in an examination of an ancient sword. It was tried to find indication of forgery or, if authentic, any later processing and alteration. Metal components of the hilt and the blade were analysed by instrumental photon activation. Non-destructive metallurgical studies (hardness measurements, microscopic microstructure analysis) are briefly described, too. The results of these investigations did not yield indication of non-authenticity. This stood in agreement with the results of stylistic and scientific studies by weapon experts.

  1. Comparative Analysis of Various Aspects of Plateletpheresis on the Fenwal Amicus and Fresenius COM.TEC Cell Separator Instruments.

    PubMed

    Philip, Joseph; Biswas, Amit Kumar; Chatterjee, Tathagata; Mallhi, Rajiv Singh

    2014-01-01

    To compare the Fenwal Amicus and the Fresenius COM.TEC apheresis instruments regarding donor peripheral blood parameters, operational variables of the instruments, and quality control parameters of the product obtained. We performed 100 platelet collections from 100 voluntary donors using the 2 studied devices. We measured platelet count using an automated analyzer and analyzed the activation statuses using a flow cytometer. The median time needed to perform the procedures was significantly longer with the COM.TEC. However, the product we obtained using the Amicus instrument showed higher degrees of platelet-activation. All products we obtained with both instruments had white blood cell counts of less than 5 × 10(6) per bag. We observed no statistical difference regarding collection efficiency and collection rates between the devices. Both instruments collected platelets efficiently, with minimal donor discomfort. Compared with the COM.TEC instrument, the Amicus reached the platelet target yield more quickly; however, it displayed an increase in platelet activation. Copyright© by the American Society for Clinical Pathology (ASCP).

  2. Quantitative Analysis of Heavy Metals in Children's Toys and Jewelry: A Multi-Instrument, Multitechnique Exercise in Analytical Chemistry and Public Health

    ERIC Educational Resources Information Center

    Finch, Lauren E.; Hillyer, Margot M.; Leopold, Michael C.

    2015-01-01

    For most chemistry curricula, laboratory-based activities in quantitative and instrumental analysis continue to be an important aspect of student development/training, one that can be more effective if conceptual understanding is delivered through an inquiry-based process relating the material to relevant issues of public interest and student…

  3. Evaluation of Beeswax Influence on Physical Properties of Lipstick Using Instrumental and Sensory Methods.

    PubMed

    Kasparaviciene, Giedre; Savickas, Arunas; Kalveniene, Zenona; Velziene, Saule; Kubiliene, Loreta; Bernatoniene, Jurga

    2016-01-01

    The aim of this study was to optimize the lipsticks formulation according to the physical properties and sensory attributes and investigate the relationship between instrumental and sensory analyses and evaluate the influence of the main ingredients, beeswax and oil, with analysis of lipsticks properties. Central composite design was used to optimize the mixture of oils and beeswax and cocoa butter for formulation of lipsticks. Antioxidant activity was evaluated by DPPH free radical scavenging method spectrophotometrically. Physical properties of lipsticks melting point were determined in a glass tube; the hardness was investigated with texture analyzer. Sensory analysis was performed with untrained volunteers. The optimized mixture of sea buckthorn oil and grapeseed oil mixture ratio 13.96 : 6.18 showed the highest antioxidative activity (70 ± 0.84%) and was chosen for lipstick formulation. According to the sensory and instrumental analysis results, optimal ingredients amounts for the lipstick were calculated: 57.67% mixture of oils, 19.58% beeswax, and 22.75% cocoa butter. Experimentally designed and optimized lipstick formulation had good physical properties and high scored sensory evaluation. Correlation analysis showed a significant relationship between sensory and instrumental evaluations.

  4. Evaluation of Beeswax Influence on Physical Properties of Lipstick Using Instrumental and Sensory Methods

    PubMed Central

    Kasparaviciene, Giedre; Savickas, Arunas; Kalveniene, Zenona; Velziene, Saule; Kubiliene, Loreta

    2016-01-01

    The aim of this study was to optimize the lipsticks formulation according to the physical properties and sensory attributes and investigate the relationship between instrumental and sensory analyses and evaluate the influence of the main ingredients, beeswax and oil, with analysis of lipsticks properties. Central composite design was used to optimize the mixture of oils and beeswax and cocoa butter for formulation of lipsticks. Antioxidant activity was evaluated by DPPH free radical scavenging method spectrophotometrically. Physical properties of lipsticks melting point were determined in a glass tube; the hardness was investigated with texture analyzer. Sensory analysis was performed with untrained volunteers. The optimized mixture of sea buckthorn oil and grapeseed oil mixture ratio 13.96 : 6.18 showed the highest antioxidative activity (70 ± 0.84%) and was chosen for lipstick formulation. According to the sensory and instrumental analysis results, optimal ingredients amounts for the lipstick were calculated: 57.67% mixture of oils, 19.58% beeswax, and 22.75% cocoa butter. Experimentally designed and optimized lipstick formulation had good physical properties and high scored sensory evaluation. Correlation analysis showed a significant relationship between sensory and instrumental evaluations. PMID:27994631

  5. Establishment of gold-quartz standard GQS-1

    USGS Publications Warehouse

    Millard, Hugh T.; Marinenko, John; McLane, John E.

    1969-01-01

    A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.

  6. Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

    NASA Astrophysics Data System (ADS)

    Takatsuka, Toshiko; Hirata, Kouichi; Kobayashi, Yoshinori; Kuroiwa, Takayoshi; Miura, Tsutomu; Matsue, Hideaki

    2008-11-01

    Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 1015 atoms/cm2 with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

  7. Bullet identification: a case of a fatal hunting accident resolved by comparison of lead shot using instrumental neutron activation analysis.

    PubMed

    Capannesi, G; Sedda, A F

    1992-03-01

    Bullet identification by chemical analysis often provides a powerful clue in forensic science. A case is reported in which a hunting accident was resolved by using instrumental neutron activation analysis (INAA) for direct comparison of the trace element content in lead shot. Different preparation batches of lead shot appear to have a high within-group composition homogeneity, and good differentiation is achieved between different batches. Determination of the nickel and antimony content on a bush branch demonstrated that the branch had been perforated by one of the shot pellets, and this helped the detectives in reconstruction of the crime scene.

  8. Application of instrumental neutron activation and X-ray fluorescence analysis to the examination of objects of art

    NASA Astrophysics Data System (ADS)

    Panczyk, E.; Ligeza, M.; Walis, L.

    1999-01-01

    In the Institute of Nuclear Chemistry and Technology in Warsaw in collaboration with the Department of Preservation and Restoration of Works of Art of the Academy of Fine Arts in Cracow and National Museum in Warsaw systematic studies using nuclear methods, particulary instrumental neutron activation analysis and X-ray fluorescence analysis, have been carried out on the panel paintings from the Krakowska- Nowosadecka School and Silesian School of the period from the XIV-XVII century, Chinese and Thai porcelains and mummies fillings of Egyptian sarcophagi. These studies will provide new data to the existing data base, will permit to compare materials used by various schools and individual artists.

  9. Specific cognitive functions and depressive symptoms as predictors of activities of daily living in older adults with heterogeneous cognitive backgrounds

    PubMed Central

    de Paula, Jonas J.; Diniz, Breno S.; Bicalho, Maria A.; Albuquerque, Maicon Rodrigues; Nicolato, Rodrigo; de Moraes, Edgar N.; Romano-Silva, Marco A.; Malloy-Diniz, Leandro F.

    2015-01-01

    Cognitive functioning influences activities of daily living (ADL). However, studies reporting the association between ADL and neuropsychological performance show inconsistent results regarding what specific cognitive domains are related to each specific functional domains. Additionally, whether depressive symptoms are associated with a worse functional performance in older adults is still under explored. We investigated if specific cognitive domains and depressive symptoms would affect different aspects of ADL. Participants were 274 older adults (96 normal aging participants, 85 patients with mild cognitive impairment, and 93 patients probable with mild Alzheimer’s disease dementia) with low formal education (∼4 years). Measures of ADL included three complexity levels: Self-care, Instrumental-Domestic, and Instrumental-Complex. The specific cognitive functions were evaluated through a factorial strategy resulting in four cognitive domains: Executive Functions, Language/Semantic Memory, Episodic Memory, and Visuospatial Abilities. The Geriatric Depression Scale measured depressive symptoms. Multiple linear regression analysis showed executive functions and episodic memory as significant predictors of Instrumental-Domestic ADL, and executive functions, episodic memory and language/semantic memory as predictors of Instrumental-Complex ADL (22 and 28% of explained variance, respectively). Ordinal regression analysis showed the influence of specific cognitive functions and depressive symptoms on each one of the instrumental ADL. We observed a heterogeneous pattern of association with explained variance ranging from 22 to 38%. Different instrumental ADL had specific cognitive predictors and depressive symptoms were predictive of ADL involving social contact. Our results suggest a specific pattern of influence depending on the specific instrumental daily living activity. PMID:26257644

  10. Comparing the Psychometric Properties of Two Physical Activity Self-Efficacy Instruments in Urban, Adolescent Girls: Validity, Measurement Invariance, and Reliability

    PubMed Central

    Voskuil, Vicki R.; Pierce, Steven J.; Robbins, Lorraine B.

    2017-01-01

    Aims: This study compared the psychometric properties of two self-efficacy instruments related to physical activity. Factorial validity, cross-group and longitudinal invariance, and composite reliability were examined. Methods: Secondary analysis was conducted on data from a group randomized controlled trial investigating the effect of a 17-week intervention on increasing moderate to vigorous physical activity among 5th–8th grade girls (N = 1,012). Participants completed a 6-item Physical Activity Self-Efficacy Scale (PASE) and a 7-item Self-Efficacy for Exercise Behaviors Scale (SEEB) at baseline and post-intervention. Confirmatory factor analyses for intervention and control groups were conducted with Mplus Version 7.4 using robust weighted least squares estimation. Model fit was evaluated with the chi-square index, comparative fit index, and root mean square error of approximation. Composite reliability for latent factors with ordinal indicators was computed from Mplus output using SAS 9.3. Results: Mean age of the girls was 12.2 years (SD = 0.96). One-third of the girls were obese. Girls represented a diverse sample with over 50% indicating black race and an additional 19% identifying as mixed or other race. Both instruments demonstrated configural invariance for simultaneous analysis of cross-group and longitudinal invariance based on alternative fit indices. However, simultaneous metric invariance was not met for the PASE or the SEEB instruments. Partial metric invariance for the simultaneous analysis was achieved for the PASE with one factor loading identified as non-invariant. Partial metric invariance was not met for the SEEB. Longitudinal scalar invariance was achieved for both instruments in the control group but not the intervention group. Composite reliability for the PASE ranged from 0.772 to 0.842. Reliability for the SEEB ranged from 0.719 to 0.800 indicating higher reliability for the PASE. Reliability was more stable over time in the control group for both instruments. Conclusions: Results suggest that the intervention influenced how girls responded to indicator items. Neither of the instruments achieved simultaneous metric invariance making it difficult to assess mean differences in PA self-efficacy between groups. PMID:28824487

  11. Measuring heterosexual LGBT ally development: a Rasch analysis.

    PubMed

    Ji, Peter; Fujimoto, Ken

    2013-01-01

    An instrument was developed that measured heterosexual persons' level of lesbian, gay, bisexual, and transgender (LGBT) ally identity. Using a Rasch analysis, 2 dimensions were observed: (a) internal and interpersonal and (b) activity. Persons with high levels of LGBT ally identities endorsed items about having LGBT knowledge, attitudes, and skills; having interpersonal experiences with LGBT communities; and including LGBT ally as part of their identities. The instrument met criteria for the content, substantive, structural, generalizability, and responsiveness validity. The instrument can be used to assist persons to develop their abilities to support and advocate for equality for LGBT communities.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Heinrich, R.R.; Jensen, K.J.

    Technical and administrative activities of the Analytical Chemistry Laboratory (ACL) are reported for fiscal year 1984. The ACL is a full-cost-recovery service center, with the primary mission of providing a broad range of technical support services to the scientific and engineering programs at ANL. In addition, ACL conducts a research program in analytical chemistry, works on instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL is administratively within the Chemical Technology Division, the principal user, but provides technical support for all of the technical divisions and programs at ANL. The ACL has threemore » technical groups - Chemical Analysis, Instrumental Analysis, and Organic Analysis. Under technical activities 26 projects are briefly described. Under professional activities, a list is presented for publications and reports, oral presentations, awards and meetings attended. 6 figs., 2 tabs.« less

  13. Space and Earth Sciences, Computer Systems, and Scientific Data Analysis Support, Volume 1

    NASA Technical Reports Server (NTRS)

    Estes, Ronald H. (Editor)

    1993-01-01

    This Final Progress Report covers the specific technical activities of Hughes STX Corporation for the last contract triannual period of 1 June through 30 Sep. 1993, in support of assigned task activities at Goddard Space Flight Center (GSFC). It also provides a brief summary of work throughout the contract period of performance on each active task. Technical activity is presented in Volume 1, while financial and level-of-effort data is presented in Volume 2. Technical support was provided to all Division and Laboratories of Goddard's Space Sciences and Earth Sciences Directorates. Types of support include: scientific programming, systems programming, computer management, mission planning, scientific investigation, data analysis, data processing, data base creation and maintenance, instrumentation development, and management services. Mission and instruments supported include: ROSAT, Astro-D, BBXRT, XTE, AXAF, GRO, COBE, WIND, UIT, SMM, STIS, HEIDI, DE, URAP, CRRES, Voyagers, ISEE, San Marco, LAGEOS, TOPEX/Poseidon, Pioneer-Venus, Galileo, Cassini, Nimbus-7/TOMS, Meteor-3/TOMS, FIFE, BOREAS, TRMM, AVHRR, and Landsat. Accomplishments include: development of computing programs for mission science and data analysis, supercomputer applications support, computer network support, computational upgrades for data archival and analysis centers, end-to-end management for mission data flow, scientific modeling and results in the fields of space and Earth physics, planning and design of GSFC VO DAAC and VO IMS, fabrication, assembly, and testing of mission instrumentation, and design of mission operations center.

  14. Cutting efficiency of Reciproc and waveOne reciprocating instruments.

    PubMed

    Plotino, Gianluca; Giansiracusa Rubini, Alessio; Grande, Nicola M; Testarelli, Luca; Gambarini, Gianluca

    2014-08-01

    The aim of the present study was to evaluate the cutting efficiency of 2 new reciprocating instruments, Reciproc and WaveOne. Twenty-four new Reciproc R25 and 24 new WaveOne Primary files were activated by using a torque-controlled motor (Silver Reciproc) and divided into 4 groups (n = 12): group 1, Reciproc activated by Reciproc ALL program; group 2, Reciproc activated by WaveOne ALL program; group 3, WaveOne activated by Reciproc ALL program; and group 4, WaveOne activated by WaveOne ALL program. The device used for the cutting test consisted of a main frame to which a mobile plastic support for the handpiece is connected and a stainless steel block containing a Plexiglas block (inPlexiglass, Rome, Italy) against which the cutting efficiency of the instruments was tested. The length of the block cut in 1 minute was measured in a computerized program with a precision of 0.1 mm. Means and standard deviations of each group were calculated, and data were statistically analyzed with 1-way analysis of variance and Bonferroni test (P < .05). Reciproc R25 displayed greater cutting efficiency than WaveOne Primary for both the movements used (P < .05); in particular, Reciproc instruments used with their proper reciprocating motion presented a statistically significant higher cutting efficiency than WaveOne instruments used with their proper reciprocating motion (P < .05). There was no statistically significant difference between the 2 movements for both instruments (P > .05). Reciproc instruments demonstrated statistically higher cutting efficiency than WaveOne instruments. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  15. Alignment of Outcome Instruments Used in Hand Therapy With the Occupational Therapy Practice Framework: Domain and Process and the International Classification of Functioning, Disability and Health: A Scoping Review.

    PubMed

    Lesher, Danielle Ann-Marie; Mulcahey, M J; Hershey, Peter; Stanton, Donna Breger; Tiedgen, Andrea C

    We sought to identify outcome instruments used in rehabilitation of the hand and upper extremity; to determine their alignment with the constructs of the International Classification of Functioning, Disability and Health (ICF) and the Occupational Therapy Practice Framework: Domain and Process; and to report gaps in the constructs measured by outcome instruments as a basis for future research. We searched CINAHL, MEDLINE, OTseeker, and the Cochrane Central Register of Controlled Trials using scoping review methodology and evaluated outcome instruments for concordance with the ICF and the Framework. We identified 18 outcome instruments for analysis. The findings pertain to occupational therapists' focus on body functions, body structures, client factors, and activities of daily living; a gap in practice patterns in use of instruments; and overestimation of the degree to which instruments used are occupationally based. Occupational therapy practitioners should use outcome instruments that embody conceptual frameworks for classifying function and activity. Copyright © 2017 by the American Occupational Therapy Association, Inc.

  16. Transportation forecasting : analysis and quantitative methods

    DOT National Transportation Integrated Search

    1983-01-01

    This Record contains the following papers: Development of Survey Instruments Suitable for Determining Non-Home Activity Patterns; Sequential, History-Dependent Approach to Trip-Chaining Behavior; Identifying Time and History Dependencies of Activity ...

  17. Psychometric Properties of the Arabic Version of the Summary of Diabetes Self-Care Activities Instrument.

    PubMed

    Sukkarieh-Haraty, Ola; Howard, Elizabeth

    2016-01-01

    Translation of instruments needs to ensure equivalence between the source and the target language to establish the psychometric properties of the translated version. The purpose of this study was to examine the psychometric properties of the Arabic version of the Summary of Diabetes Self-Care Activities (SDSCA) instrument. The 12-item English version of the SDSCA was translated into Arabic using back translation on a sample of 140 Lebanese participants with Type 2 diabetes. Construct validity was measured using exploratory factor analysis with varimax rotation. Multitrait scaling analysis was used to test for item convergent and discriminant validity based on item-scale correlations. Conceptual and content validity were examined by an expert panel in diabetes. Internal consistency reliability R was assessed using interitem correlations. The average interitem correlation for the four subscales ranged between--.05 for Diet and .66 for Glucose Testing. Factor analysis identified four factors which accounted for 60% of the variance. The preliminary results of Summary of Diabetes Self-Care Activities-Arabic Version (SDSCA-Ar) are comparable to the psychometric properties the original SDSCA. SDSCA-Ar is a valid measure of diabetes self-care in Lebanese patients with diabetes.

  18. A Virtual Instrument System for Determining Sugar Degree of Honey

    PubMed Central

    Wu, Qijun; Gong, Xun

    2015-01-01

    This study established a LabVIEW-based virtual instrument system to measure optical activity through the communication of conventional optical instrument with computer via RS232 port. This system realized the functions for automatic acquisition, real-time display, data processing, results playback, and so forth. Therefore, it improved accuracy of the measurement results by avoiding the artificial operation, cumbersome data processing, and the artificial error in optical activity measurement. The system was applied to the analysis of the batch inspection on the sugar degree of honey. The results obtained were satisfying. Moreover, it showed advantages such as friendly man-machine dialogue, simple operation, and easily expanded functions. PMID:26504615

  19. 30 CFR 280.30 - What activities will not require environmental analysis?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... types of activities include: (a) Gravity and magnetometric observations and measurements; (b) Bottom and..., including the setting of instruments; (g) Sampling by box core or grab sampler to determine seabed...

  20. Highly efficient, very low-thrust transfer to geosynchronous orbit - Exact and approximate solutions

    NASA Astrophysics Data System (ADS)

    Redding, D. C.

    1984-04-01

    An overview is provided of the preflight, postflight, and accuracy analysis of the Titan IIIC launch vehicle that injects payloads into geosynchronous orbits. The postflight trajectory reconstruction plays an important role in determining payload injection accuracy. Furthermore, the postflight analysis provides useful information about the characteristics of measuring instruments subjected to a flight environment. Suitable approaches for meeting mission specifications, trajectory requirements, and instrument constraints are considered, taking into account the importance of preflight trajectory analysis activities. Gimbal flip avoidance algorithms in the flight software, and considerable beta gimbal analysis ensures a singularity-free trajectory.

  1. The Efficacy of Problem-Based Learning in an Instrumental Analyse Laboratory

    ERIC Educational Resources Information Center

    Seyhan, Hatice Güngör

    2016-01-01

    In the context of the study, an instrumental analysis laboratory course offering Problem-Based Learning (PBL) was designed as an alternative to traditional laboratory practices. The study was conducted with a total of 36 volunteer, prospective chemistry teachers consisting of fourth year undergraduates and graduates. While PBL activities were…

  2. Application of epithermal neutron activation in multielement analysis of silicate rocks employing both coaxial Ge(Li) and low energy photon detector systems

    USGS Publications Warehouse

    Baedecker, P.A.; Rowe, J.J.; Steinnes, E.

    1977-01-01

    The instrumental activation analysis of silicate rocks using epithermal neutrons has been studied using both high resolution coaxial Ge(Li) detectors and low energy photon detectors, and applied to the determination of 23 elements in eight new U.S.G.S. standard rocks. The analytical use X-ray peaks associated with electron capture or internal conversion processes has been evaluated. Of 28 elements which can be considered to be determinable by instrumental means, the epithermal activation approach is capable of giving improved sensitivity and precision in 16 cases, over the normal INAA procedure. In eleven cases the use of the low energy photon detector is thought to show advantages over convertional coaxial Ge(Li) spectroscopy. ?? 1977 Akade??miai Kiado??.

  3. The relationship between thoracic hyperkyphosis and the Scoliosis Research Society outcomes instrument.

    PubMed

    Petcharaporn, Maty; Pawelek, Jeff; Bastrom, Tracey; Lonner, Baron; Newton, Peter O

    2007-09-15

    A retrospective chart review and radiographic analysis. To evaluate the association between thoracic hyperkyphosis and patient quality of life measures as determined by the Scoliosis Research Society (SRS) outcomes instrument. Although validated outcomes questionnaires (e.g., Pediatric Outcomes Data Collection Instrument and SRS) have been used to evaluate patients with scoliosis, there has been little written about the effects of sagittal plane alignment on these functional outcome measurements. Data from the SRS outcomes instrument were collected from patients with thoracic hyperkyphosis as well as those with normal spinal alignment. A total of 50 patients with thoracic kyphosis >or=45 degrees were compared with 50 normal patients with thoracic kyphosis <45 degrees . Correlation analysis was performed to identify significant relationships between the magnitude of the major kyphotic curve and the 4 SRS outcome questionnaire domains (Total Pain, General Self-Image, General Function, and Activity). Lower SRS scores indicate an increase in symptoms. The average age of the subjects was 14 +/- 4 years (range, 8-18 years). The thoracic kyphosis varied between 11 degrees and 95 degrees for all subjects. Significant negative correlations were found between kyphosis magnitude and the total pain, general self-image, general function, overall level of activity, and total SRS scores (P < 0.0001). Of the 4 domains, self-image had the highest correlation with kyphosis magnitude while activity had the lowest. These findings indicate that higher kyphosis magnitudes were associated with increased pain, lower self-image, and decreased function and activity. Patients with thoracic hyperkyphosis were significantly more symptomatic than normal subjects in all domains. The r values for this analysis of kyphosis (0.40-0.66), in fact were substantially greater than those previously reported for scoliosis magnitude versus SRS Questionnaire scores (0.16-0.26), suggesting this instrument may be even better suited for the evaluation of hyperkyphosis patients.

  4. Measuring physical activity and sports participation after autologous cartilage implantation: a systematic review.

    PubMed

    Santos-Magalhaes, Andre Filipe; Hambly, Karen

    2014-08-01

    The assessment of physical activity and return to sport and exercise activities is an important component in the overall evaluation of outcome after autologous cartilage implantation (ACI). To identify the patient-report instruments that are commonly used in the evaluation of physical activity and return to sport after ACI and provide a critical analysis of these instruments from a rehabilitative perspective. A computerized search was performed in January 2013 and repeated in March 2013. Criteria for inclusion required that studies (1) be written in English and published between 1994 and 2013; (2) be clinical studies where knee ACI cartilage repair was the primary treatment, or comparison studies between ACI and other techniques or between different ACI generations; (3) report postoperative physical activity and sport participation outcomes results, and (4) have evidence level of I-III. Twenty-six studies fulfilled the inclusion criteria. Three physical activity scales were identified: the Tegner Activity Scale, Modified Baecke Questionnaire, and Activity Rating Scale. Five knee-specific instruments were identified: the Lysholm Knee Function Scale, International Knee Documentation Committee Score Subjective Form, Knee Injury and Osteoarthritis Outcome Score, Modified Cincinnati Knee Score, and Stanmore-Bentley Functional Score. Considerable heterogeneity exists in the reporting of physical activity and sports participation after ACI. Current instruments do not fulfill the rehabilitative needs in the evaluation of physical activity and sports participation.

  5. An Integrated Approach to Thermal Analysis of Pharmaceutical Solids

    ERIC Educational Resources Information Center

    Riley, Shelley R. Rabel

    2015-01-01

    A three-tiered experiment for undergraduate Instrumental Analysis students is presented in which students characterize the solid-state thermal behavior of an active pharmaceutical ingredient (acetaminophen) and excipient (a-lactose hydrate) using differential scanning calorimetry, thermogravimetric analysis, and thermal microscopy. Students are…

  6. Instrumental neutron activation analysis data for cloud-water particulate samples, Mount Bamboo, Taiwan

    USGS Publications Warehouse

    Lin, Neng-Huei; Sheu, Guey-Rong; Wetherbee, Gregory A.; Debey, Timothy M.

    2013-01-01

    Cloud water was sampled on Mount Bamboo in northern Taiwan during March 22-24, 2002. Cloud-water samples were filtered using 0.45-micron filters to remove particulate material from the water samples. Filtered particulates were analyzed by instrumental neutron activation analysis (INAA) at the U.S. Geological Survey National Reactor Facility in Denver, Colorado, in February 2012. INAA elemental composition data for the particulate materials are presented. These data complement analyses of the aqueous portion of the cloud-water samples, which were performed earlier by the Department of Atmospheric Sciences, National Central University, Taiwan. The data are intended for evaluation of atmospheric transport processes and air-pollution sources in Southeast Asia.

  7. Italy INAF Analysis Center Report

    NASA Technical Reports Server (NTRS)

    Negusini, M.; Sarti, P.

    2013-01-01

    This report summarizes the activity of the Italian INAF VLBI Analysis Center. Our Analysis Center is located in Bologna, Italy and belongs to the Institute of Radioastronomy, which is part of the National Institute of Astrophysics. IRA runs the observatories of Medicina and Noto, where two 32-m VLBI AZ-EL telescopes are situated. This report contains the AC's VLBI data analysis activities and shortly outlines the investigations into the co-locations of space geodetic instruments.

  8. Characterisation and optimisation of the new Prompt Gamma-ray Activation Analysis (PGAA) facility at FRM II

    NASA Astrophysics Data System (ADS)

    Canella, Lea; Kudějová, Petra; Schulze, Ralf; Türler, Andreas; Jolie, Jan

    2011-04-01

    At the research reactor Forschungs-Neutronenquelle Heinz Maier-Leibnitz (FRM II) a new Prompt Gamma-ray Activation Analysis (PGAA) facility was installed. The instrument was originally built and operating at the spallation source at the Paul Scherrer Institute in Switzerland. After a careful re-design in 2004-2006, the new PGAA instrument was ready for operation at FRM II. In this paper the main characteristics and the current operation conditions of the facility are described. The neutron flux at the sample position can reach up 6.07×1010 [cm-2 s-1], thus the optimisation of some parameters, e.g. the beam background, was necessary in order to achieve a satisfactory analytical sensitivity for routine measurements. Once the optimal conditions were reached, detection limits and sensitivities for some elements, like for example H, B, C, Si, or Pb, were calculated and compared with other PGAA facilities. A standard reference material was also measured in order to show the reliability of the analysis under different conditions at this instrument.

  9. International Instrumentation Symposium, 32nd, Seattle, WA, May 5-8, 1986, Proceedings

    NASA Astrophysics Data System (ADS)

    The conference presents papers on blast, shock, and vibration instrumentation; wind tunnel instrumentation and controls; electrooptic and fiber optic instrumentation; special test facilities; reentry vehicle testing; and nondestructive test and acoustic test instrumentation. Other topic include real time systems, flight test and avionics instrumentation, data aquisition and analysis systems, thermal measurements, and advances in measurement technology. Particular attention is given to an automated fringe counting laser interferometer for low frequency vibration measurements, dynamic pressure measurements in pneumatic lines, optically interfaced sensor system for aerospace applications, the picobalance for single microparticle measurements, ellipsometric film thickness, nanometer wear measurement by ultrathin surface layer activation, a rugged electronic scanner designed for turbine test, failure mechanism characterization of platinum alloy, and the thick film strain gage.

  10. Organizational member involvement in physical activity coalitions across the United States: development and testing of a novel survey instrument for assessing coalition functioning.

    PubMed

    Bornstein, Daniel B; Pate, Russell R; Beets, Michael W; Saunders, Ruth P; Blair, Steven N

    2015-06-01

    Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement in physical activity coalitions. The study was carried out in three phases: (a) developing a draft survey, (b) assessing the content validity of the draft survey, and (c) assessing the underlying factor structure, reliability, and validity of the survey. A cross-sectional design was employed. In Phase 1, a team of experts in survey development produced a draft survey. In Phase 2, the content validity of the draft survey was evaluated by a panel of individuals with expertise in physical activity coalitions. In Phase 3, the survey was administered to 120 individuals on local-, state-, and national-level physical activity coalitions. Responses were subjected to an exploratory factor analysis in order to determine the survey's underlying factor structure, reliability, and validity. Phases 1 and 2yielded a survey instrument with demonstrated content validity. Phase 3 yielded a three-factor model with three subscales: Strategic Alignment, Organizational Alignment, and Providing Input. Each subscale demonstrated high internal consistency reliability and construct validity. The survey instrument developed here demonstrated sound psychometric properties and provides new insight into organizational member involvement in physical activity coalitions. This instrument may be an important tool in developing a more complete picture of coalition functioning in physical activity coalitions specifically and health-based coalitions overall. © 2014 Society for Public Health Education.

  11. Synthesis of 4-aminophenyl substituted indole derivatives for the instrumental analysis and molecular docking evaluation studies

    NASA Astrophysics Data System (ADS)

    Singh, Navneet; Kumar, Keshav

    2017-07-01

    The Indole has been known to maintain celebrity status since so many decades and has been a centre point at the spectrum of pharmacological research. The present work stimulates an idea of generating a pool of library of lead compounds. The data collected can be used for the mapping of biologically active compounds. The reported derivatives of 4-aminophenyl substituted Indole were prepared by the methods of Fischer Indole synthesis and Vilsemeier reaction followed by screening for instrumental analysis and molecular docking studies. The synthesized compounds 4-(1-(2-phenylhydrazono)ethyl)aniline, 1, 4-(1H-indol-2-yl)aniline, 2 and 2-(4-aminophenyl)-1H-indole-3-carbaldehyde, 3 were found to have remarkable yield and instrumental data analysis and also showed remarkable docked characteristic. The molecular docking studies revealed that ligand (amino acids) of comp. 1, 2 and 3 had been docked successfully on the binding site of the 3JUS protein selected from PDB with H bonding. The molecular docking data showed that compound 1, would possess remarkable biological activity and compd. 2 and 3 would possess mild to moderate biological activity. Thus this research work paves the way to synthesize new derivatives and thus to develop new compounds in future with accurate prediction.

  12. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 4; Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giuletta S. (Editor); McClain, Charles R. (Editor); Pegau, Scott; Zaneveld, J. Ronald V.; Mitchell, B. Gregg; Kahru, Mati; Wieland, John; Stramska, Malgorzat

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  13. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4, Volume IV: Inherent Optical Properties: Instruments, Characterizations, Field Measurements and Data Analysis Protocols

    NASA Technical Reports Server (NTRS)

    Mueller, J. L.; Fargion, G. S.; McClain, C. R. (Editor); Pegau, S.; Zanefeld, J. R. V.; Mitchell, B. G.; Kahru, M.; Wieland, J.; Stramska, M.

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparision and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background, and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 is entirely superseded by the six volumes of Revision 4 listed above.

  14. Leisure Activity Patterns and Their Associations with Overweight: A Prospective Study among Adolescents

    ERIC Educational Resources Information Center

    Lajunen, Hanna-Reetta; Keski-Rahkonen, Anna; Pulkkinen, Lea; Rose, Richard J.; Rissanen, Aila; Kaprio, Jaakko

    2009-01-01

    We examined longitudinal associations between individual leisure activities (television viewing, video viewing, computer games, listening to music, board games, musical instrument playing, reading, arts, crafts, socializing, clubs or scouts, sports, outdoor activities) and being overweight using logistic regression and latent class analysis in a…

  15. The development of PROQOL-HIV: an international instrument to assess the health-related quality of life of persons living with HIV/AIDS.

    PubMed

    Duracinsky, Martin; Herrmann, Susan; Berzins, Baiba; Armstrong, Andrew R; Kohli, Rewa; Le Coeur, Sophie; Diouf, Assane; Fournier, Isabelle; Schechter, Mauro; Chassany, Olivier

    2012-04-15

    Health-related quality of life (HRQL) is an important outcome in HIV/AIDS infection and treatment. However, most existing HIV-HRQL instruments miss important issues (eg, sleeping problems, lipodystrophy). They were developed before highly active antiretroviral therapy (pre-HAART), and in a single language. We sought to develop a contemporary HIV-HRQL instrument (PROQOL-HIV) in multiple languages that accounts for HAART treatment and side effects. This article details the 3-stage content validation phase of PROQOL-HIV. In stage 1, we developed a conceptual model of HIV-HRQL and questionnaire item bank from thematic analysis of 152 patient interviews conducted simultaneously across 9 countries. In stage 2, pilot items were selected by an expert panel to form the pilot instrument. Stage 3 involved linguistic validation and harmonization of selected items to form an equivalent instrument in 9 target languages. Analysis of 3375 pages of interview text revealed 11 underlying themes: general health perception, social relationships, emotions, energy/fatigue, sleep, cognitive functioning, physical and daily activity, coping, future, symptoms, and treatment. Seven issues new to HIV-HRQL measurement were subsumed by these themes: infection fears, future concerns, satisfaction with care, self-esteem problems, sleep problems, work disruption, and treatment issues. Of the 442 theme-related items banked, 70 items met the retention criteria and formed the pilot PROQOL-HIV instrument. HIV patients across 11 countries attributed a wide range of physical, mental, and social issues to their condition, many of which were not measured by existing HIV-HRQL instruments. The pilot PROQOL-HIV instrument captures these issues, is sensitive to sociocultural context, disease stage, and HAART.

  16. Experimental parameters optimization of instrumental neutron activation analysis in order to determine selected elements in some industrial soils in Turkey

    NASA Astrophysics Data System (ADS)

    Haciyakupoglu, Sevilay; Nur Esen, Ayse; Erenturk, Sema

    2014-08-01

    The purpose of this study is optimization of the experimental parameters for analysis of soil matrix by instrumental neutron activation analysis and quantitative determination of barium, cerium, lanthanum, rubidium, scandium and thorium in soil samples collected from industrialized urban areas near Istanbul. Samples were irradiated in TRIGA MARK II Research Reactor of Istanbul Technical University. Two types of reference materials were used to check the accuracy of the applied method. The achieved results were found to be in compliance with certified values of the reference materials. The calculated En numbers for mentioned elements were found to be less than 1. The presented data of element concentrations in soil samples will help to trace the pollution as an impact of urbanization and industrialization, as well as providing database for future studies.

  17. Characterization of ancient glass excavated in Enez (Ancient Ainos) Turkey by combined Instrumental Neutron Activation Analysis and Fourier Transform Infrared spectrometry techniques

    NASA Astrophysics Data System (ADS)

    Akyuz, Sevim; Akyuz, Tanil; Mukhamedshina, Nuranya M.; Mirsagatova, A. Adiba; Basaran, Sait; Cakan, Banu

    2012-05-01

    Ancient glass fragments excavated in the archaeological district Enez (Ancient Ainos)-Turkey were investigated by combined Instrumental Neutron Activation Analysis (INAA) and Fourier Transform Infrared (FTIR) spectrometry techniques. Multi-elemental contents of 15 glass fragments that belong to Hellenistic, Roman, Byzantine, and Ottoman Periods, were determined by INAA. The concentrations of twenty six elements (Na, K, Ca, Sc, Cr, Mn, Fe, Co, Cu, Zn, As, Rb, Sr, Sb, Cs, Ba, Ce, Sm, Eu, Tb, Yb, Lu, Hf, Ta, Au and Th), which might be present in the samples as flux, stabilizers, colorants or opacifiers, and impurities, were examined. Chemometric treatment of the INAA data was performed and principle component analysis revealed presence of 3 distinct groups. The thermal history of the glass samples was determined by FTIR spectrometry.

  18. Determination of Interesting Toxicological Elements in PM2.5 by Neutron and Photon Activation Analysis

    PubMed Central

    Capannesi, Geraldo; Lopez, Francesco

    2013-01-01

    Human activities introduce compounds increasing levels of many dangerous species for environment and population. In this way, trace elements in airborne particulate have a preeminent position due to toxic element presence affecting the biological systems. The main problem is the analytical determination of such species at ultratrace levels: a very specific methodology is necessary with regard to the accuracy and precision and contamination problems. Instrumental Neutron Activation Analysis and Instrumental Photon Activation Analysis assure these requirements. A retrospective element analysis in airborne particulate collected in the last 4 decades has been carried out for studying their trend. The samples were collected in urban location in order to determine only effects due to global aerosol circulation; semiannual samples have been used to characterize the summer/winter behavior of natural and artificial origin. The levels of natural origin element are higher than those in other countries owing to geological and meteorological factors peculiar to Central Italy. The levels of artificial elements are sometimes less than those in other countries, suggesting a less polluted general situation for Central Italy. However, for a few elements (e.g., Pb) the levels measured are only slight lower than those proposed as air ambient standard. PMID:23878525

  19. Sampled control stability of the ESA instrument pointing system

    NASA Astrophysics Data System (ADS)

    Thieme, G.; Rogers, P.; Sciacovelli, D.

    Stability analysis and simulation results are presented for the ESA Instrument Pointing System (IPS) that is to be used in Spacelab's second launch. Of the two IPS plant dynamic models used in the ESA and NASA activities, one is based on six interconnected rigid bodies that represent the IPS and plant dynamic models used in the ESA and NASA activities, one is based on six interconnected rigid bodies that represent the IPS and its payload, while the other follows the NASA practice of defining an IPS-Spacelab 2 plant configuration through a structural finite element model, which is then used to generate modal data for various pointing directions. In both cases, the IPS dynamic plant model is truncated, then discretized at the sampling frequency and interfaces to a PID-based control law. A stability analysis has been carried out in discrete domain for various instrument pointing directions, taking into account suitable parameter variation ranges. A number of time simulations are presented.

  20. CV 990 interface test and procedure analysis of the monkey restraint, support equipment, and telemetry electronics proposed for Spacelab

    NASA Technical Reports Server (NTRS)

    Newsom, B. D.

    1978-01-01

    A biological system proposed to restrain a monkey in the Spacelab was tested under operational conditions using typical metabolic and telemetered cardiovascular instrumentation. Instrumentation, interfaced with other electronics, and data gathering during a very active operational mission were analyzed for adequacy of procedure and success of data handling by the onboard computer.

  1. Department of Defense In-House RDT and E Activities

    DTIC Science & Technology

    1976-10-30

    BALLISTIC TESTS.FAC AVAL FCR TESIS OF SP ELELTRONIC’ FIl’ CON EQUIP 4 RELATED SYSTEMS E COMPONFNTZ, 35 INSTALLATION: MEDICAL BIOENGINEERINC- R&D LABORATORY...ANALYSIS OF CHEMICAL AND METALLOGRAPHIC EFFECTS, MICROBIOLOGICAL EFFECTS, CLIMATIC ENVIRONMENTAL EFFECTS. TEST AND EVALUATE WARHEADS AND SPECIAL...CCMMUNICATI’N SYST:M INSTRUMENTED DROP ZONES ENGINEERING TEST FACILITY INSTRUMENTATION CALIBRATICN FACILITY SCIENTIFIC COMPUTER CENTER ENVIRONMENTAL TESY

  2. Ames collaborative study of cosmic ray neutrons

    NASA Technical Reports Server (NTRS)

    Hewitt, J. E.; Hughes, L.; Mccaslin, J. B.; Stephens, L. D.; Rindi, A.; Smith, A. R.; Thomas, R. H.; Griffith, R. V.; Welles, C. G.; Baum, J. W.

    1976-01-01

    The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

  3. SNS Sample Activation Calculator Flux Recommendations and Validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McClanahan, Tucker C.; Gallmeier, Franz X.; Iverson, Erik B.

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples.more » The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.« less

  4. Using Remote Access to Scientific Instrumentation to Create Authentic Learning Activities in Pharmaceutical Analysis

    PubMed Central

    Albon, Simon P.; Cancilla, Devon A.; Hubball, Harry

    2006-01-01

    Objectives To pilot test and evaluate a gas chromatography-mass spectrometry (GCMS) case study as a teaching and learning tool. Design A case study incorporating remote access to a GCMS instrument through the Integrated Laboratory Network (ILN) at Western Washington University was developed and implemented. Student surveys, faculty interviews, and examination score data were used to evaluate learning. Assessment While the case study did not impact final examination scores, approximately 70% of students and all faculty members felt the ILN-supported case study improved student learning about GCMS. Faculty members felt the “live” instrument access facilitated more authentic teaching. Students and faculty members felt the ILN should continue to be developed as a teaching tool. Conclusion Remote access to scientific instrumentation can be used to modify case studies to enhance student learning and teaching practice in pharmaceutical analysis. PMID:17149450

  5. Automatic classification of minimally invasive instruments based on endoscopic image sequences

    NASA Astrophysics Data System (ADS)

    Speidel, Stefanie; Benzko, Julia; Krappe, Sebastian; Sudra, Gunther; Azad, Pedram; Müller-Stich, Beat Peter; Gutt, Carsten; Dillmann, Rüdiger

    2009-02-01

    Minimally invasive surgery is nowadays a frequently applied technique and can be regarded as a major breakthrough in surgery. The surgeon has to adopt special operation-techniques and deal with difficulties like the complex hand-eye coordination and restricted mobility. To alleviate these constraints we propose to enhance the surgeon's capabilities by providing a context-aware assistance using augmented reality techniques. To analyze the current situation for context-aware assistance, we need intraoperatively gained sensor data and a model of the intervention. A situation consists of information about the performed activity, the used instruments, the surgical objects, the anatomical structures and defines the state of an intervention for a given moment in time. The endoscopic images provide a rich source of information which can be used for an image-based analysis. Different visual cues are observed in order to perform an image-based analysis with the objective to gain as much information as possible about the current situation. An important visual cue is the automatic recognition of the instruments which appear in the scene. In this paper we present the classification of minimally invasive instruments using the endoscopic images. The instruments are not modified by markers. The system segments the instruments in the current image and recognizes the instrument type based on three-dimensional instrument models.

  6. Disability Measurement for Korean Community-Dwelling Adults With Stroke: Item-Level Psychometric Analysis of the Korean Longitudinal Study of Ageing

    PubMed Central

    2018-01-01

    Objective To investigate the psychometric properties of the activities of daily living (ADL) instrument used in the analysis of Korean Longitudinal Study of Ageing (KLoSA) dataset. Methods A retrospective study was carried out involving 2006 KLoSA records of community-dwelling adults diagnosed with stroke. The ADL instrument used for the analysis of KLoSA included 17 items, which were analyzed using Rasch modeling to develop a robust outcome measure. The unidimensionality of the ADL instrument was examined based on confirmatory factor analysis with a one-factor model. Item-level psychometric analysis of the ADL instrument included fit statistics, internal consistency, precision, and the item difficulty hierarchy. Results The study sample included a total of 201 community-dwelling adults (1.5% of the Korean population with an age over 45 years; mean age=70.0 years, SD=9.7) having a history of stroke. The ADL instrument demonstrated unidimensional construct. Two misfit items, money management (mean square [MnSq]=1.56, standardized Z-statistics [ZSTD]=2.3) and phone use (MnSq=1.78, ZSTD=2.3) were removed from the analysis. The remaining 15 items demonstrated good item fit, high internal consistency (person reliability=0.91), and good precision (person strata=3.48). The instrument precisely estimated person measures within a wide range of theta (−4.75 logits < θ < 3.97 logits) and a reliability of 0.9, with a conceptual hierarchy of item difficulty. Conclusion The findings indicate that the 15 ADL items met Rasch expectations of unidimensionality and demonstrated good psychometric properties. It is proposed that the validated ADL instrument can be used as a primary outcome measure for assessing longitudinal disability trajectories in the Korean adult population and can be employed for comparative analysis of international disability across national aging studies. PMID:29765888

  7. Transportable, Low-Dose Active Fast-Neutron Imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mihalczo, John T.; Wright, Michael C.; McConchie, Seth M.

    2017-08-01

    This document contains a description of the method of transportable, low-dose active fast-neutron imaging as developed by ORNL. The discussion begins with the technique and instrumentation and continues with the image reconstruction and analysis. The analysis discussion includes an example of how a gap smaller than the neutron production spot size and detector size can be detected and characterized depending upon the measurement time.

  8. Cost prediction model for various payloads and instruments for the Space Shuttle Orbiter

    NASA Technical Reports Server (NTRS)

    Hoffman, F. E.

    1984-01-01

    The following cost parameters of the space shuttle were undertaken: (1) to develop a cost prediction model for various payload classes of instruments and experiments for the Space Shuttle Orbiter; and (2) to show the implications of various payload classes on the cost of: reliability analysis, quality assurance, environmental design requirements, documentation, parts selection, and other reliability enhancing activities.

  9. Physical Behavior in Older Persons during Daily Life: Insights from Instrumented Shoes.

    PubMed

    Moufawad El Achkar, Christopher; Lenoble-Hoskovec, Constanze; Paraschiv-Ionescu, Anisoara; Major, Kristof; Büla, Christophe; Aminian, Kamiar

    2016-08-03

    Activity level and gait parameters during daily life are important indicators for clinicians because they can provide critical insights into modifications of mobility and function over time. Wearable activity monitoring has been gaining momentum in daily life health assessment. Consequently, this study seeks to validate an algorithm for the classification of daily life activities and to provide a detailed gait analysis in older adults. A system consisting of an inertial sensor combined with a pressure sensing insole has been developed. Using an algorithm that we previously validated during a semi structured protocol, activities in 10 healthy elderly participants were recorded and compared to a wearable reference system over a 4 h recording period at home. Detailed gait parameters were calculated from inertial sensors. Dynamics of physical behavior were characterized using barcodes that express the measure of behavioral complexity. Activity classification based on the algorithm led to a 93% accuracy in classifying basic activities of daily life, i.e., sitting, standing, and walking. Gait analysis emphasizes the importance of metrics such as foot clearance in daily life assessment. Results also underline that measures of physical behavior and gait performance are complementary, especially since gait parameters were not correlated to complexity. Participants gave positive feedback regarding the use of the instrumented shoes. These results extend previous observations in showing the concurrent validity of the instrumented shoes compared to a body-worn reference system for daily-life physical behavior monitoring in older adults.

  10. Determination of minor and trace elements concentration in kidney stones using elemental analysis techniques

    NASA Astrophysics Data System (ADS)

    Srivastava, Anjali

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. The X-ray fluorescence (XRF) and neutron activation analysis (NAA) experiments were performed and different kidney stones were analyzed. The interactions of X-ray photons and neutrons with matter are complementary in nature, resulting in distinctly different materials detection. This is the first approach to utilize combined X-ray fluorescence and neutron activation analysis for a comprehensive analysis of the kideny stones. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. The use of open source program Python Multi-Channel Analyzer was utilized to unfold the XRF spectrum. A new type of experimental set-up was developed and utilized for XRF and NAA analysis of the kidney stone. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF and NAA technique. The elements which were identified from XRF technique are Br, Cu, Ga, Ge, Mo, Nb, Ni, Rb, Se, Sr, Y, Zr. And, by using Neutron Activation Analysis (NAA) are Au, Br, Ca, Er, Hg, I, K, Na, Pm, Sb, Sc, Sm, Tb, Yb, Zn. This thesis presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF and NAA instrumental activation analysis techniques.

  11. Assessing research activity and capacity of community-based organizations: development and pilot testing of an instrument.

    PubMed

    Humphries, Debbie L; Carroll-Scott, Amy; Mitchell, Leif; Tian, Terry; Choudhury, Shonali; Fiellin, David A

    2014-01-01

    Although awareness of the importance of the research capacity of community-based organizations (CBOs) is growing, a uniform framework of the research capacity domains within CBOs has not yet been developed. To develop a framework and instrument (the Community REsearch Activity assessment Tool [CREAT]) for assessing the research activity and capacity of CBOs that incorporates awareness of the different data collection and analysis priorities of CBOs. We conducted a review of existing tools for assessing research capacity to identify key capacity domains. Instrument items were developed through an iterative process with CBO representatives and community researchers. The CREAT was then pilot tested with 30 CBOs. The four primary domains of the CREAT framework include 1) organizational support for research, 2) generalizable experiences, 3) research specific experiences, and 4) funding. Organizations reported a high prevalence of activities in the research-specific experiences domain, including conducting literature reviews (70%), use of research terminology (83%), and primary data collection (100%). Respondents see research findings as important to improve program and service delivery, and to seek funds for new programs and services. Funders, board members, and policymakers are the most important dissemination audiences. The work reported herein advances the field of CBO research capacity by developing a systematic framework for assessing research activity and capacity relevant to the work of CBOs, and by developing and piloting an instrument to assess activity in these domains.

  12. SpecViz: Interactive Spectral Data Analysis

    NASA Astrophysics Data System (ADS)

    Earl, Nicholas Michael; STScI

    2016-06-01

    The astronomical community is about to enter a new generation of scientific enterprise. With next-generation instrumentation and advanced capabilities, the need has arisen to equip astronomers with the necessary tools to deal with large, multi-faceted data. The Space Telescope Science Institute has initiated a data analysis forum for the creation, development, and maintenance of software tools for the interpretation of these new data sets. SpecViz is a spectral 1-D interactive visualization and analysis application built with Python in an open source development environment. A user-friendly GUI allows for a fast, interactive approach to spectral analysis. SpecViz supports handling of unique and instrument-specific data, incorporation of advanced spectral unit handling and conversions in a flexible, high-performance interactive plotting environment. Active spectral feature analysis is possible through interactive measurement and statistical tools. It can be used to build wide-band SEDs, with the capability of combining or overplotting data products from various instruments. SpecViz sports advanced toolsets for filtering and detrending spectral lines; identifying, isolating, and manipulating spectral features; as well as utilizing spectral templates for renormalizing data in an interactive way. SpecViz also includes a flexible model fitting toolset that allows for multi-component models, as well as custom models, to be used with various fitting and decomposition routines. SpecViz also features robust extension via custom data loaders and connection to the central communication system underneath the interface for more advanced control. Incorporation with Jupyter notebooks via connection with the active iPython kernel allows for SpecViz to be used in addition to a user’s normal workflow without demanding the user drastically alter their method of data analysis. In addition, SpecViz allows the interactive analysis of multi-object spectroscopy in the same straight-forward, consistent way. Through the development of such tools, STScI hopes to unify astronomical data analysis software for JWST and other instruments, allowing for efficient, reliable, and consistent scientific results.

  13. Mercury and gold concentrations of highly polluted environmental samples determined using prompt gamma-ray analysis and instrument neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Osawa, Takahito; Hatsukawa, Yuichi; Appel, Peter W. U.; Matsue, Hideaki

    2011-04-01

    The authors have established a method of determining mercury and gold in severely polluted environmental samples using prompt gamma-ray analysis (PGA) and instrumental neutron activation analysis (INAA). Since large amounts of mercury are constantly being released into the environment by small-scale gold mining in many developing countries, the mercury concentration in tailings and water has to be determined to mitigate environmental pollution. Cold-vapor atomic absorption analysis, the most pervasive method of mercury analysis, is not suitable because tailings and water around mining facilities have extremely high mercury concentrations. On the other hand, PGA can determine high mercury concentrations in polluted samples as it has an appropriate level of sensitivity. Moreover, gold concentrations can be determined sequentially by using INAA after PGA. In conclusion, the analytical procedure established in this work using PGA and INAA is the best way to evaluate the degree of pollution and the tailing resource value. This method will significantly contribute to mitigating problems in the global environment.

  14. Item-Level Psychometrics of the Glasgow Outcome Scale: Extended Structured Interviews.

    PubMed

    Hong, Ickpyo; Li, Chih-Ying; Velozo, Craig A

    2016-04-01

    The Glasgow Outcome Scale-Extended (GOSE) structured interview captures critical components of activities and participation, including home, shopping, work, leisure, and family/friend relationships. Eighty-nine community dwelling adults with mild-moderate traumatic brain injury (TBI) were recruited (average = 2.7 year post injury). Nine items of the 19 items were used for the psychometrics analysis purpose. Factor analysis and item-level psychometrics were investigated using the Rasch partial-credit model. Although the principal components analysis of residuals suggests that a single measurement factor dominates the measure, the instrument did not meet the factor analysis criteria. Five items met the rating scale criteria. Eight items fit the Rasch model. The instrument demonstrated low person reliability (0.63), low person strata (2.07), and a slight ceiling effect. The GOSE demonstrated limitations in precisely measuring activities/participation for individuals after TBI. Future studies should examine the impact of the low precision of the GOSE on effect size. © The Author(s) 2016.

  15. Data evaluation, analysis, and scientific study

    NASA Technical Reports Server (NTRS)

    Wu, S. T.

    1991-01-01

    Extensive work was performed in data analysis and modeling of solar active phenomena. The work consisted in the study of UV data from the Ultraviolet Spectrometer and Polarimeter (UVSP) instrument on board the Solar Maximum Mission satellite. These data were studied in conjunction with X-rays from the Hard X-ray Imaging Spectrometer (HXIS) instrument, and with H-alpha and magnetographic data from ground-based observatories. The processes we studied are the active phenomena which result from the interaction of the solar magnetic fields with the plasma in the outer regions of the solar atmosphere. These processes include some very dynamic processes such as the prominence eruptions and the 'microflares'. Our research aimed at characterizing the following: the observed phenomena, the possible physical models, and the relevance to the chromospheric and coronal heating.

  16. Teaching Group Work with "The Great Debaters"

    ERIC Educational Resources Information Center

    Moe, Jeffry; Autry, Linda; Olson, Joann S.; Johnson, Kaprea F.

    2014-01-01

    An experiential learning activity, based on the film "The Great Debaters" (Washington, D., 2007), was used during a group work class. Description and preliminary evaluation of the activity is provided, including analysis of participant scores on the group leader self-efficacy instrument at multiple points. Implications and future…

  17. Measuring Disability: Application of the Rasch Model to Activities of Daily Living (ADL/IADL).

    ERIC Educational Resources Information Center

    Sheehan, T. Joseph; DeChello, Laurie M.; Garcia, Ramon; Fifield, Judith; Rothfield, Naomi; Reisine, Susan

    2001-01-01

    Performed a comparative analysis of Activities of Daily Living (ADL) items administered to 4,430 older adults and Instrumental Activities of Daily Living administered to 605 people with rheumatoid arthritis scoring both with Likert and Rasch measurement models. Findings show the superiority of the Rasch approach over the Likert method. (SLD)

  18. Partial pressure analysis in space testing

    NASA Technical Reports Server (NTRS)

    Tilford, Charles R.

    1994-01-01

    For vacuum-system or test-article analysis it is often desirable to know the species and partial pressures of the vacuum gases. Residual gas or Partial Pressure Analyzers (PPA's) are commonly used for this purpose. These are mass spectrometer-type instruments, most commonly employing quadrupole filters. These instruments can be extremely useful, but they should be used with caution. Depending on the instrument design, calibration procedures, and conditions of use, measurements made with these instruments can be accurate to within a few percent, or in error by two or more orders of magnitude. Significant sources of error can include relative gas sensitivities that differ from handbook values by an order of magnitude, changes in sensitivity with pressure by as much as two orders of magnitude, changes in sensitivity with time after exposure to chemically active gases, and the dependence of the sensitivity for one gas on the pressures of other gases. However, for most instruments, these errors can be greatly reduced with proper operating procedures and conditions of use. In this paper, data are presented illustrating performance characteristics for different instruments and gases, operating parameters are recommended to minimize some errors, and calibrations procedures are described that can detect and/or correct other errors.

  19. Risk factors for unavoidable removal of instrumentation after surgical site infection of spine surgery

    PubMed Central

    Tominaga, Hiroyuki; Setoguchi, Takao; Kawamura, Hideki; Kawamura, Ichiro; Nagano, Satoshi; Abematsu, Masahiko; Tanabe, Fumito; Ishidou, Yasuhiro; Yamamoto, Takuya; Komiya, Setsuro

    2016-01-01

    Abstract Surgical site infection (SSI) after spine instrumentation is difficult to treat, and often requires removal of instrumentation. The removal of instrumentation after spine surgery is a severe complication that can lead to the deterioration of activities of daily living and poor prognosis. Although there are many reports on SSI after spine surgery, few reports have investigated the risk factors for the removal of instrumentation after spine surgery SSI. This study aimed to identify the risk factors for unavoidable removal of instrumentation after SSI of spine surgery. We retrospectively reviewed 511 patients who underwent spine surgery with instrumentation at Kagoshima University Hospital from January 2006 to December 2014. Risk factors associated with SSI were analyzed via multiple logistic regression analysis. Parameters of the group that needed instrumentation removal were compared with the group that did not require instrumentation removal using the Mann–Whitney U and Fisher's exact tests. The posterior approach was used in most cases (453 of 511 cases, 88.6%). SSI occurred in 16 of 511 cases (3.14%) of spine surgery with instrumentation. Multivariate logistic regression analysis identified 2 significant risk factors for SSI: operation time, and American Society of Anesthesiologists physical status classification ≥ 3. Twelve of the 16 patients with SSI (75%) were able to keep the instrumentation after SSI. Pseudarthrosis occurred in 2 of 4 cases (50%) after instrumentation removal. Risk factors identified for instrumentation removal after spine SSI were a greater number of past surgeries, low preoperative hemoglobin, high preoperative creatinine, high postoperative infection treatment score for the spine, and the presence of methicillin-resistant Staphylococcus aureus. In these high risk cases, attempts should be made to decrease the risk factors preoperatively, and careful postoperative monitoring should be conducted. PMID:27787365

  20. Risk factors for unavoidable removal of instrumentation after surgical site infection of spine surgery: A retrospective case-control study.

    PubMed

    Tominaga, Hiroyuki; Setoguchi, Takao; Kawamura, Hideki; Kawamura, Ichiro; Nagano, Satoshi; Abematsu, Masahiko; Tanabe, Fumito; Ishidou, Yasuhiro; Yamamoto, Takuya; Komiya, Setsuro

    2016-10-01

    Surgical site infection (SSI) after spine instrumentation is difficult to treat, and often requires removal of instrumentation. The removal of instrumentation after spine surgery is a severe complication that can lead to the deterioration of activities of daily living and poor prognosis. Although there are many reports on SSI after spine surgery, few reports have investigated the risk factors for the removal of instrumentation after spine surgery SSI. This study aimed to identify the risk factors for unavoidable removal of instrumentation after SSI of spine surgery. We retrospectively reviewed 511 patients who underwent spine surgery with instrumentation at Kagoshima University Hospital from January 2006 to December 2014. Risk factors associated with SSI were analyzed via multiple logistic regression analysis. Parameters of the group that needed instrumentation removal were compared with the group that did not require instrumentation removal using the Mann-Whitney U and Fisher's exact tests. The posterior approach was used in most cases (453 of 511 cases, 88.6%). SSI occurred in 16 of 511 cases (3.14%) of spine surgery with instrumentation. Multivariate logistic regression analysis identified 2 significant risk factors for SSI: operation time, and American Society of Anesthesiologists physical status classification ≥ 3. Twelve of the 16 patients with SSI (75%) were able to keep the instrumentation after SSI. Pseudarthrosis occurred in 2 of 4 cases (50%) after instrumentation removal. Risk factors identified for instrumentation removal after spine SSI were a greater number of past surgeries, low preoperative hemoglobin, high preoperative creatinine, high postoperative infection treatment score for the spine, and the presence of methicillin-resistant Staphylococcus aureus. In these high risk cases, attempts should be made to decrease the risk factors preoperatively, and careful postoperative monitoring should be conducted.

  1. Using confirmatory factor analysis to validate the Chamberlin affective instrument for mathematical problem solving with academically advanced students.

    PubMed

    Chamberlin, Scott A; Moore, Alan D; Parks, Kelly

    2017-09-01

    Student affect plays a considerable role in mathematical problem solving performance, yet is rarely formally assessed. In this manuscript, an instrument and its properties are discussed to enable educational psychologists the opportunity to assess student affect. The study was conducted to norm the CAIMPS (instrument) with gifted students. In so doing, educational psychologists are informed of the process and the instrument's properties. The sample was comprised of 160 middle-grade (7 and 8) students, identified as gifted, in the United States. After completing one of four model-eliciting activities (MEAs), all participants completed the CAIMPS (Chamberlin Affective Instrument for Mathematical Problem Solving). Data were analysed using confirmatory factor analysis to ascertain the number of factors in the instrument. The normed fit index (0.6939), non-normed fit index (0.8072), and root mean square error approximation (.076) were at or near the acceptable levels. Alpha levels for factors were also robust (.637-.923). Data suggest that the instrument was a good fit for use with mathematics students in middle grades when solving problems. Perhaps the most impressive characteristic of the instrument was that the four factors (AVI: anxiety, value, and interest), SS (self-efficacy and self-esteem), ASP (aspiration), and ANX (anxiety) did not correlate highly with one another, which defies previous hypotheses in educational psychology. © 2017 The British Psychological Society.

  2. DAN instrument for NASA`s MSL mission: fast science data processing and instrument commanding for Mars surface operations and for field tests

    NASA Astrophysics Data System (ADS)

    Vostrukhin, A.; Kozyrev, A.; Litvak, M.; Malakhov, A.; Mitrofanov, I.; Mokrousov, M.; Sanin, A.; Tretyakov, V.

    2009-04-01

    The Dynamic Albedo of Neutrons (DAN) instrument is contributed by Russian Space Agency to NASA for Mars Science Laboratory mission which was originally scheduled for 2009 and now is shifted to 2011. The design of DAN instrument is partially inherited from HEND instrument for NASA's Mars Odyssey, which now successfully operates providing global mapping of martian neutron albedo, searching the distribution of martian water and observing the martian seasonal cycles. DAN is specially designed as an active neutron instrument for surface operations onboard mobile platforms. It is able to focus science investigations on local surface area around rover with horizontal resolution about 1 meter and vertical penetration about 0.5 m. The primary goal of DAN is the exploration of the hydrogen content of the bulk Martian subsurface material. This data will be used to estimate the content of chemically bound water in the hydrated minerals. The concept of DAN operations is based on combination of neutron activation analysis and neutron well logging tequnique, which are commonly used in the Earth geological applications. DAN consists blocks of Detectors and Electronics (DE) and Pulse Neutron Generator (PNG). The last one is used to irradiate the martian subsurface by pulses of 14MeV neutrons with changeable frequency up to 10 Hz. The first one detects post-pulse afterglow of neutrons, as they were thermalized down to epithermal and thermal energies within the martian subsurface. The result of detections are so called die away curves of neutrons afterglow, which show flux and time profile of thermalized neutrons and bring to us the observational signature of layering structure of martian regolith in part of depth distribution of Hydrogen (most effective element for thermalization of neutrons). In this study we focus on the development, verification and validation of DAN fast data processing and commanding. It is necessary to perform deconvolution from counting statistic in DAN detectors (raw data) to the real science products such as estimated average content of Hydrgen content or its depth distribution along the rover trace. For the rover surface operations it is necessary to provide real time data analysis to combine DAN data with data from all another science instruments and to develop the best observation strategy for the future periods of operation activity. In our approach we use: 1) Onboard FPGA data processing for recording neutron die away curves for epthermal and thermal neutrons of post-pulse afterglow 2) Getting raw data of DAN at the Mission operation center 3) Validation of instrument parameters and operational performance 4) Fast first level science data processing (statistical analysis, background subtraction, normalization) 5) Fast deconvolution of detector counts into the Hydrogen content (including numerical simulation, comparison with the known standard models of regolith), 6) Comparison with known information obtained with another instruments 7) Development of the near-term and long-term strategy for next DAN operations onboard MSL. 8) Generation and testing commanding sequences for the next period of MSL autonomous operations All this activity shall be adjusted in the real time, so the steps 2-8 shall not exceed 2-3 hours. Before launch we plan to validate this approach trough the instrument calibrations, field tests and MSL science group activity. The first experience will be presented of fast data analysis and commanding for the field tests of DAN, which were performed in the testing facility of the Joint Institute of Nuclear Research (Russia). Also, we will discuss our plans of DAN operations for coming field tests in Antarctica.

  3. Cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments in artificial canals.

    PubMed

    Higuera, Oscar; Plotino, Gianluca; Tocci, Luigi; Carrillo, Gabriela; Gambarini, Gianluca; Jaramillo, David E

    2015-06-01

    The purpose of this study was to evaluate the cyclic fatigue resistance of 3 different nickel-titanium reciprocating instruments. A total of 45 nickel-titanium instruments were tested and divided into 3 experimental groups (n = 15): group 1, WaveOne Primary instruments; group 2, Reciproc R25 instruments; and group 3, Twisted File (TF) Adaptive M-L1 instruments. The instruments were then subjected to cyclic fatigue test on a static model consisting of a metal block with a simulated canal with 60° angle of curvature and a 5-mm radius of curvature. WaveOne Primary, Reciproc R25, and TF Adaptive instruments were activated by using their proprietary movements, WaveOne ALL, Reciproc ALL, and TF Adaptive, respectively. All instruments were activated until fracture occurred, and the time to fracture was recorded visually for each file with a 1/100-second chronometer. Mean number of cycles to failure and standard deviations were calculated for each group, and data were statistically analyzed (P < .05). Instruments were also observed through scanning electron microscopy to evaluate type of fracture. Cyclic fatigue resistance of Reciproc R25 and TF Adaptive M-L1 was significantly higher than that of WaveOne Primary (P = .009 and P = .002, respectively). The results showed no statistically significant difference between TF Adaptive M-L1 and Reciproc R25 (P = .686). Analysis of the fractured portion under scanning electron microscopy indicated that all instruments showed morphologic characteristics of ductile fracture that were due to accumulation of metal fatigue. No statistically significant differences were found between the instruments tested except for WaveOne Primary, which showed the lowest resistance to cyclic fatigue. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  4. Space radiation studies

    NASA Technical Reports Server (NTRS)

    Gregory, J. C.

    1986-01-01

    Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

  5. Decision-Making by Handball Referees: Design of an ad hoc Observation Instrument and Polar Coordinate Analysis.

    PubMed

    Morillo, Juan P; Reigal, Rafael E; Hernández-Mendo, Antonio; Montaña, Alejandro; Morales-Sánchez, Verónica

    2017-01-01

    Referees are essential for sports such as handball. However, there are few tools available to analyze the activity of handball referees. The aim of this study was to design an instrument for observing the behavior of referees in handball competitions and to analyze the resulting data by polar coordinate analysis. The instrument contained 6 criteria and 18 categories and can be used to monitor and describe the actions of handball referees according to their role/position on the playing court. For the data quality control analysis, we calculated Pearson's (0.99), Spearman's (0.99), and Tau Kendall's (1.00) correlation coefficients and Cohen's kappa (entre 0.72 y 0.75) and Phi (entre 0.83 y 0.87) coefficients. In the generalizability analysis, the absolute and relative generalizability coefficients were 0.99 in both cases. Polar coordinate analysis of referee decisions showed that correct calls were more common for central court and 7-meter throw calls. Likewise, calls were more likely to be incorrect (in terms of both errors of omission and commission) when taken from the goal-line position.

  6. Decision-Making by Handball Referees: Design of an ad hoc Observation Instrument and Polar Coordinate Analysis

    PubMed Central

    Morillo, Juan P.; Reigal, Rafael E.; Hernández-Mendo, Antonio; Montaña, Alejandro; Morales-Sánchez, Verónica

    2017-01-01

    Referees are essential for sports such as handball. However, there are few tools available to analyze the activity of handball referees. The aim of this study was to design an instrument for observing the behavior of referees in handball competitions and to analyze the resulting data by polar coordinate analysis. The instrument contained 6 criteria and 18 categories and can be used to monitor and describe the actions of handball referees according to their role/position on the playing court. For the data quality control analysis, we calculated Pearson's (0.99), Spearman's (0.99), and Tau Kendall's (1.00) correlation coefficients and Cohen's kappa (entre 0.72 y 0.75) and Phi (entre 0.83 y 0.87) coefficients. In the generalizability analysis, the absolute and relative generalizability coefficients were 0.99 in both cases. Polar coordinate analysis of referee decisions showed that correct calls were more common for central court and 7-meter throw calls. Likewise, calls were more likely to be incorrect (in terms of both errors of omission and commission) when taken from the goal-line position. PMID:29104553

  7. Development of an instrument to analyze organizational characteristics in multidisciplinary care pathways; the case of colorectal cancer.

    PubMed

    Pluimers, Dorine J; van Vliet, Ellen J; Niezink, Anne Gh; van Mourik, Martijn S; Eddes, Eric H; Wouters, Michel W; Tollenaar, Rob A E M; van Harten, Wim H

    2015-04-09

    To analyze the organization of multidisciplinary care pathways such as colorectal cancer care, an instrument was developed based on a recently published framework that was earlier used in analyzing (monodisciplinary) specialist cataract care from a lean perspective. The instrument was constructed using semi-structured interviews and direct observation of the colorectal care process based on a Rapid Plant Assessment. Six lean aspects that were earlier established that highly impact process design, were investigated: operational focus, autonomous work cell, physical lay-out of resources, multi-skilled team, pull planning and non-value adding activities. To test reliability, clarity and face validity of the instrument, a pilot study was performed in eight Dutch hospitals. In the pilot it proved feasible to apply the instrument and generate the intended information. The instrument consisted of 83 quantitative and 24 qualitative items. Examples of results show differences in operational focus, number of patient visits needed for diagnosis, numbers of staff involved with treatment, the implementation of protocols and utilization of one-stop-shops. Identification of waste and non-value adding activities may need further attention. Based on feedback from involved clinicians the face validity was acceptable and the results provided useful feedback- and benchmark data. The instrument proved to be reliable and valid for broader implementation in Dutch health care. The limited number of cases made statistical analysis not possible and further validation studies may shed better light on variation. This paper demonstrates the use of an instrument to analyze organizational characteristics in colorectal cancer care from a lean perspective. Wider use might help to identify best organizational practices for colorectal surgery. In larger series the instrument might be used for in-depth research into the relation between organization and patient outcomes. Although we found no reason to adapt the underlying framework, recommendations were made for further development to enable use in different tumor- and treatment modalities and in larger (international) samples that allow for more advanced statistical analysis. Waste from defective care or from wasted human potential will need further elaboration of the instrument.

  8. Reliability and construct validity of the Participation in Life Activities Scale for children and adolescents with asthma: an instrument evaluation study.

    PubMed

    Kintner, Eileen K; Sikorskii, Alla

    2008-06-04

    The purpose of this study was to evaluate the reliability and construct validity of the Participation in Life Activities Scale, an instrument designed to measure older school-age child and early adolescent level of involvement in chosen pursuits. A cross-sectional design was used. The convenience sample consisted of 313 school-age children and early adolescents with asthma, ages 9-15 years. The self-report summative scale of interest is a 3-indicator survey. Higher scores are reflective of higher levels of participation. Internal consistency reliability and construct validity for the entire sample and sub groups of the sample were evaluated. The instrument was deemed sound for the entire sample as well as sub groups based on sex, race, age, socioeconomic status, and severity of illness. Cronbach's alpha coefficient for internal consistency reliability for the entire sample was .74. Exploratory factor analysis indicated a single component solution (loadings .79-.85) accounting for 66% of the explained variance. Construct validity was established by testing the posed relationship between participation in life activities scores and severity of illness. Confirmatory factor analysis revealed a good fit between the data and specified model, chi2(10, n = 302) = 8.074, p = .62. This instrument could be used (a) in clinical settings to diagnose restricted participation in desired activities, guide decision-making about treatment plans to increase participation, and motivate behavioral change in the management of asthma; and (b) in research settings to explore factors influencing and consequences of restricted and unrestricted participation, and as an outcome measure to evaluate the effectiveness of programs designed to foster child and early adolescent management of asthma.

  9. Executive summary: Mod-1 wind turbine generator analysis and design report

    NASA Technical Reports Server (NTRS)

    1979-01-01

    Activities leading to the detail design of a wind turbine generator having a nominal rating of 1.8 megawatts are reported. Topics covered include (1) system description; (2) structural dynamics; (3) stability analysis; (4) mechanical subassemblies design; (5) power generation subsystem; and (6) control and instrumentation subsystem.

  10. Gamma Ray Astronomy

    NASA Technical Reports Server (NTRS)

    Wu, S. T.

    2000-01-01

    The project has progressed successfully during this period of performance. The highlights of the Gamma Ray Astronomy teams efforts are: (1) Support daily BATSE data operations, including receipt, archival and dissemination of data, quick-look science analysis, rapid gamma-ray burst and transient monitoring and response efforts, instrument state-of-health monitoring, and instrument commanding and configuration; (2) On-going scientific analysis, including production and maintenance of gamma-ray burst, pulsed source and occultation source catalogs, gamma-ray burst spectroscopy, studies of the properties of pulsars and black holes, and long-term monitoring of hard x-ray sources; (3) Maintenance and continuous improvement of BATSE instrument response and calibration data bases; (4) Investigation of the use of solid state detectors for eventual application and instrument to perform all sky monitoring of X-Ray and Gamma sources with high sensitivity; and (5) Support of BATSE outreach activities, including seminars, colloquia and World Wide Web pages. The highlights of this efforts can be summarized in the publications and presentation list.

  11. Chemical characterization of gas- and oil-bearing shales by instrumental neutron activation analysis

    USGS Publications Warehouse

    Frost, J.K.; Koszykowski, R.F.; Klemm, R.C.

    1982-01-01

    The concentration of As, Ba, Ca, Co, Cr, Cs, Dy, Eu, Fe, Ga, Hf, K, La, Lu, Mn, Mo, Na, Ni, Rb, Sb, Sc, Se, Sm, Sr, Ta, Tb, Th, U, Yb, and Zn were determined by instrumental neutron activation analysis in block shale samples of the New Albany Group (Devonian-Mississippian) in the in the Illinois Basin. Uranium content of the samples was as high as 75 ppm and interfered in the determination of samarium, molybdenum, barium and cerium. In the determination of selenium a correction was made for interference from tantalum. U, As, Co, Mo, Ni and Sb as well as Cu, V and pyritic sulphur which were determined by other methods, were found to correlate positively with the organic carbon content of the samples. ?? 1982 Akade??miai Kiado??.

  12. Hybrid architecture active wavefront sensing and control system, and method

    NASA Technical Reports Server (NTRS)

    Feinberg, Lee D. (Inventor); Dean, Bruce H. (Inventor); Hyde, Tristram T. (Inventor)

    2011-01-01

    According to various embodiments, provided herein is an optical system and method that can be configured to perform image analysis. The optical system can comprise a telescope assembly and one or more hybrid instruments. The one or more hybrid instruments can be configured to receive image data from the telescope assembly and perform a fine guidance operation and a wavefront sensing operation, simultaneously, on the image data received from the telescope assembly.

  13. Continued reduction and analysis of data from the Dynamics Explorer Plasma Wave Instrument

    NASA Technical Reports Server (NTRS)

    Gurnett, Donald A.; Weimer, Daniel R.

    1994-01-01

    The plasma wave instrument on the Dynamics Explorer 1 spacecraft provided measurements of the electric and magnetic components of plasma waves in the Earth's magnetosphere. Four receiver systems processed signals from five antennas. Sixty-seven theses, scientific papers and reports were prepared from the data generated. Data processing activities and techniques used to analyze the data are described and highlights of discoveries made and research undertaken are tabulated.

  14. Development of a Portable, Ground-Based Ozone Lidar Instrument for Tropospheric Ozone Research and Educational Training

    NASA Technical Reports Server (NTRS)

    Chyba, Thomas; Zenker, Thomas

    1998-01-01

    The objective of this project is to develop a portable, eye-safe, ground-based ozone lidar instrument specialized for ozone differential absorption lidar (DIAL) measurements in the troposphere. This prototype instrument is intended to operate at remote field sites and to serve as the basic unit for monitoring projects requiring multi-instrument networks, such as that discussed in the science plan for the Global Tropospheric Ozone Project (GTOP). This instrument will be based at HU for student training in lidar technology as well as atmospheric ozone data analysis and interpretation. It will be also available for off-site measurement campaigns and will serve as a test bed for further instrument development. Later development beyond this grant to extend the scientific usefulness of the instrument may include incorporation of an aerosol channel and upgrading the laser to make stratospheric ozone measurements. Undergraduate and graduate students have been and will be active participants in this research effort.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Boparai, A.S.; Bowers, D.L.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for fiscal year (FY) 1995 (October 1994 through September 1995). This annual report is the twelfth for the ACL and describes work on 54 continuing and new projects and contributions of the ACL staff to various programs at ANL. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis.

  16. Soft Particle Spectrometer, Langmuir Probe, and Data Analysis for Aerospace Magnetospheric/Thermospheric Coupling Rocket Program

    NASA Technical Reports Server (NTRS)

    Sharber, J. R.; Frahm, R. A.; Scherrer, J. R.

    1997-01-01

    Under this grant two instruments, a soft particle spectrometer and a Langmuir probe, were refurbished and calibrated, and flown on three instrumented rocket payloads as part of the Magnetosphere/Thermosphere Coupling program. The flights took place at the Poker Flat Research Range on February 12, 1994 (T(sub o) = 1316:00 UT), February 2, 1995 (T(sub o) = 1527:20 UT), and November 27, 1995 (T(sub o) = 0807:24 UT). In this report the observations of the particle instrumentation flown on all three of the flights are described, and brief descriptions of relevant geophysical activity for each flight are provided. Calibrations of the particle instrumentation for all ARIA flights are also provided.

  17. LEISURE ACTIVITY PATTERNS AND THEIR ASSOCIATIONS WITH OVERWEIGHT: A PROSPECTIVE STUDY AMONG ADOLESCENTS

    PubMed Central

    Lajunen, Hanna-Reetta; Keski-Rahkonen, Anna; Pulkkinen, Lea; Rose, Richard J.; Rissanen, Aila; Kaprio, Jaakko

    2009-01-01

    We examined longitudinal associations between individual leisure activities (television viewing, video viewing, computer games, listening to music, board games, musical instrument playing, reading, arts, crafts, socializing, clubs or scouts, sports, outdoor activities) and being overweight using logistic regression and latent class analysis in a cohort of Finnish twins responding to self-report questionnaires at 11–12 (N=5184), 14, and 17 years. We also studied activity patterns (“Active and sociable”, “Active but less sociable”, “Passive but sociable”, “Passive and solitary”) thought to represent different lifestyles. Among boys, activity patterns did not predict becoming overweight, but sports and playing an instrument reduced the risk and arts and listening to music increased it. Among girls, few individual leisure activities predicted becoming overweight. However, girls in the “Passive and solitary” cluster carried the greatest risk of becoming overweight in late adolescence. Studying leisure activities related to overweight may help focus specific interventions on high risk groups. PMID:19345989

  18. Study of the structure changes caused by volcanic activity in Mexico applying the lineament analysis to the Aster (Terra) satellite data.

    NASA Astrophysics Data System (ADS)

    Arellano-Baeza, A. A.; Garcia, R. V.; Trejo-Soto, M.; Molina-Sauceda, E.

    Mexico is one of the most volcanically active regions in North America Volcanic activity in central Mexico is associated with the subduction of the Cocos and Rivera plates beneath the North American plate Periods of enhanced microseismic activity associated with the volcanic activity of the Colima and Popocapetl volcanoes are compared to some periods of low microseismic activity We detected changes in the number and orientation of lineaments associated with the microseismic activity due to lineament analysis of a temporal sequence of high resolution satellite images of both volcanoes 15 m resolution multispectral images provided by the ASTER VNIR instrument were used The Lineament Extraction and Stripes Statistic Analysis LESSA software package was employed for the lineament extraction

  19. 6-Methylsulfinylhexyl isothiocyanate and its homologues as food-originated compounds with antibacterial activity against Escherichia coli and Staphylococcus aureus.

    PubMed

    Ono, H; Tesaki, S; Tanabe, S; Watanabe, M

    1998-02-01

    Cruciferae plants, banana and coriander each showed antibacterial activity. The highest activity among the food-stuffs tested was found in the stems of wasabi. An ethereal extract from wasabi stems had potent antibacterial activity and we isolated the active compound from the extract. Instrumental analysis identified the compound as 6-methylsulfinylhexyl isothiocyanate. Some homologues of 6-methylsulfinylhexyl isothiocyanate were also active against Escherichia coli and Staphylococcus aureus.

  20. Quantitative morphometric analysis for the tectonic characterisation of northern Tunisia.

    NASA Astrophysics Data System (ADS)

    Camafort, Miquel; Pérez-Peña, José Vicente; Booth-Rea, Guillermo; Ranero, César R.; Gràcia, Eulàlia; Azañón, José Miguel; Melki, Fetheddine; Ouadday, Mohamed

    2016-04-01

    Northern Tunisia is characterized by low deformation rates and low to moderate seismicity. Although instrumental seismicity reaches maximum magnitudes of Mw 5.5, some historical earthquakes have occurred with catastrophic consequences in this region. Aiming to improve our knowledge of active tectonics in Tunisia, we carried out both a quantitative morphometric analysis and field study in the north-western region. We applied different morphometric tools, like river profiles, knickpoint analysis, hypsometric curves and integrals and drainage pattern anomalies in order to differentiate between zones with high or low recent tectonic activity. This analysis helps identifying uplift and subsidence zones, which we relate to fault activity. Several active faults in a sparse distribution were identified. A selected sector was studied with a field campaign to test the results obtained with the quantitative analysis. During the fieldwork we identified geological evidence of recent activity and a considerable seismogenic potential along El Alia-Teboursouk (ETF) and Dkhila (DF) faults. The ETF fault could be responsible of one of the most devastating historical earthquakes in northern Tunisia that destroyed Utique in 412 A.D. Geological evidence include fluvial terraces folded by faults, striated and cracked pebbles, clastic dikes, sand volcanoes, coseismic cracks, etc. Although not reflected in the instrumental seismicity, our results support an important seismic hazard, evidenced by the several active tectonic structures identified and the two seismogenic faults described. After obtaining the current active tectonic framework of Tunisia we discuss our results within the western Mediterranean trying to contribute to the understanding of the western Mediterranean tectonic context. With our results, we suggest that the main reason explaining the sparse and scarce seismicity of the area in contrast with the adjacent parts of the Nubia-Eurasia boundary is due to its extended continental platform and its lack of proto-oceanic crust northward.

  1. Microscopic Analysis of Plankton, Periphyton, and Activated Sludge. Training Manual.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC. Office of Water Programs.

    This manual is intended for professional personnel in the fields of water pollution control, limnology, water supply and waste treatment. Primary emphasis is given to practice in the identification and enumeration of microscopic organisms which may be encountered in water and activated sludge. Methods for the chemical and instrumental evaluation…

  2. The ADL taxonomy for persons with mental disorders - adaptation and evaluation.

    PubMed

    Holmqvist, Kajsa Lidström; Holmefur, Marie

    2018-05-03

    There is a lack of occupation-focused instruments to assess Activities of Daily Living (ADL) that are intended for persons with mental disorders. The ADL Taxonomy is an instrument that is widely-used within clinical practice for persons with physical impairment. The aim of this study was to adapt the ADL Taxonomy for persons with mental disorders and evaluate its validity. An expert group of Occupational Therapists (OTs) from psychiatric care adapted the ADL Taxonomy to fit the client group, including creating three new items. OTs in psychiatric care collected client data and evaluated the instrument for usability. Rasch analysis was used to evaluate the contruct validity of 16 activities separately. The OTs collected 123 assessments from clients with various mental disorders. Ten activities had excellent, and four had acceptable, psychometric properties with regard to item and person fit and unidimensionality. The activity managing the day/time gave complex results and would benefit from further development. The OTs found the test version intelligible, relevant and easy to use. The ADL Taxonomy for persons with mental disorders has 16 activities with three to six actions each, and is now ready for clinical use.

  3. Instrumental neutron activation analysis for studying size-fractionated aerosols

    NASA Astrophysics Data System (ADS)

    Salma, Imre; Zemplén-Papp, Éva

    1999-10-01

    Instrumental neutron activation analysis (INAA) was utilized for studying aerosol samples collected into a coarse and a fine size fraction on Nuclepore polycarbonate membrane filters. As a result of the panoramic INAA, 49 elements were determined in an amount of about 200-400 μg of particulate matter by two irradiations and four γ-spectrometric measurements. The analytical calculations were performed by the absolute ( k0) standardization method. The calibration procedures, application protocol and the data evaluation process are described and discussed. They make it possible now to analyse a considerable number of samples, with assuring the quality of the results. As a means of demonstrating the system's analytical capabilities, the concentration ranges, median or mean atmospheric concentrations and detection limits are presented for an extensive series of aerosol samples collected within the framework of an urban air pollution study in Budapest. For most elements, the precision of the analysis was found to be beyond the uncertainty represented by the sampling techniques and sample variability.

  4. Active Neutron and Gamma-Ray Instrumentation for In Situ Planetary Science Applications

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Bodnarik, J.; Evans, L.; Floyd, A.; Lim, L.; McClanahan, T.; Namkung, M.; Nowicki, S.; Schweitzer, J.; Starr, R.; hide

    2011-01-01

    We describe the development of an instrument capable of detailed in situ bulk geochemical analysis of the surface of planets, moons, asteroids, and comets. This instrument technology uses a pulsed neutron generator to excite the solid materials of a planet and measures the resulting neutron and gamma-ray emission with its detector system. These time-resolved neutron and gamma-ray data provide detailed information about the bulk elemental composition, chemical context, and density distribution of the soil within 50 cm of the surface. While active neutron scattering and neutron-induced gamma-ray techniques have been used extensively for terrestrial nuclear well logging applications, our goal is to apply these techniques to surface instruments for use on any solid solar system body. As described, experiments at NASA Goddard Space Flight Center use a prototype neutron-induced gamma-ray instrument and the resulting data presented show the promise of this technique for becoming a versatile, robust, workhorse technology for planetary science, and exploration of any of the solid bodies in the solar system. The detection of neutrons at the surface also provides useful information about the material. This paper focuses on the data provided by the gamma-ray detector.

  5. Validation of an instrument to measure students' motivation and self-regulation towards technology learning

    NASA Astrophysics Data System (ADS)

    Liou, Pey-Yan; Kuo, Pei-Jung

    2014-05-01

    Background:Few studies have examined students' attitudinal perceptions of technology. There is no appropriate instrument to measure senior high school students' motivation and self-regulation toward technology learning among the current existing instruments in the field of technology education. Purpose:The present study is to validate an instrument for assessing senior high school students' motivation and self-regulation towards technology learning. Sample:A total of 1822 Taiwanese senior high school students (1020 males and 802 females) responded to the newly developed instrument. Design and method:The Motivation and Self-regulation towards Technology Learning (MSRTL) instrument was developed based on the previous instruments measuring students' motivation and self-regulation towards science learning. Exploratory and confirmatory factor analyses were utilized to investigate the structure of the items. Cronbach's alpha was applied for measuring the internal consistency of each scale. Furthermore, multivariate analysis of variance was used to examine gender differences. Results:Seven scales, including 'Technology learning self-efficacy,' 'Technology learning value,' 'Technology active learning strategies,' 'Technology learning environment stimulation,' 'Technology learning goal-orientation,' 'Technology learning self-regulation-triggering,' and 'Technology learning self-regulation-implementing' were confirmed for the MSRTL instrument. Moreover, the results also showed that male and female students did not present the same degree of preference in all of the scales. Conclusions:The MSRTL instrument composed of seven scales corresponding to 39 items was shown to be valid based on validity and reliability analyses. While male students tended to express more positive and active performance in the motivation scales, no gender differences were found in the self-regulation scales.

  6. Shortening of an existing generic online health-related quality of life instrument for dogs.

    PubMed

    Reid, J; Wiseman-Orr, L; Scott, M

    2017-10-11

    Development, initial validation and reliability testing of a shortened version of a web-based questionnaire instrument to measure generic health-related quality of life in companion dogs, to facilitate smartphone and online use. The original 46 items were reduced using expert judgment and factor analysis. Items were removed on the basis of item loadings and communalities on factors identified through factor analysis of responses from owners of healthy and unwell dogs, intrafactor item correlations, readability of items in the UK, USA and Australia and ability of individual items to discriminate between healthy and unwell dogs. Validity was assessed through factor analysis and a field trial using a "known groups" approach. Test-retest reliability was assessed using intraclass correlation coefficients. The new instrument comprises 22 items, each of which was rated by dog owners using a 7-point Likert scale. Factor analysis revealed a structure with four health-related quality of life domains (energetic/enthusiastic, happy/content, active/comfortable, and calm/relaxed) accounting for 72% of the variability in the data compared with 64% for the original instrument. The field test involving 153 healthy and unwell dogs demonstrated good discriminative properties and high intraclass correlation coefficients. The 22-item shortened form is superior to the original instrument and can be accessed via a mobile phone app. This is likely to increase the acceptability to dog owners as a routine wellness measure in health care packages and as a therapeutic monitoring tool. © 2017 British Small Animal Veterinary Association.

  7. Multi-element analysis of emeralds and associated rocks by k(o) neutron activation analysis

    PubMed

    Acharya; Mondal; Burte; Nair; Reddy; Reddy; Reddy; Manohar

    2000-12-01

    Multi-element analysis was carried out in natural emeralds, their associated rocks and one sample of beryl obtained from Rajasthan, India. The concentrations of 21 elements were assayed by Instrumental Neutron Activation Analysis using the k0 method (k0 INAA method) and high-resolution gamma ray spectrometry. The data reveal the segregation of some elements from associated (trapped and host) rocks to the mineral beryl forming the gemstones. A reference rock standard of the US Geological Survey (USGS BCR-1) was also analysed as a control of the method.

  8. Development of the Computer-Adaptive Version of the Late-Life Function and Disability Instrument

    PubMed Central

    Tian, Feng; Kopits, Ilona M.; Moed, Richard; Pardasaney, Poonam K.; Jette, Alan M.

    2012-01-01

    Background. Having psychometrically strong disability measures that minimize response burden is important in assessing of older adults. Methods. Using the original 48 items from the Late-Life Function and Disability Instrument and newly developed items, a 158-item Activity Limitation and a 62-item Participation Restriction item pool were developed. The item pools were administered to a convenience sample of 520 community-dwelling adults 60 years or older. Confirmatory factor analysis and item response theory were employed to identify content structure, calibrate items, and build the computer-adaptive testings (CATs). We evaluated real-data simulations of 10-item CAT subscales. We collected data from 102 older adults to validate the 10-item CATs against the Veteran’s Short Form-36 and assessed test–retest reliability in a subsample of 57 subjects. Results. Confirmatory factor analysis revealed a bifactor structure, and multi-dimensional item response theory was used to calibrate an overall Activity Limitation Scale (141 items) and an overall Participation Restriction Scale (55 items). Fit statistics were acceptable (Activity Limitation: comparative fit index = 0.95, Tucker Lewis Index = 0.95, root mean square error approximation = 0.03; Participation Restriction: comparative fit index = 0.95, Tucker Lewis Index = 0.95, root mean square error approximation = 0.05). Correlation of 10-item CATs with full item banks were substantial (Activity Limitation: r = .90; Participation Restriction: r = .95). Test–retest reliability estimates were high (Activity Limitation: r = .85; Participation Restriction r = .80). Strength and pattern of correlations with Veteran’s Short Form-36 subscales were as hypothesized. Each CAT, on average, took 3.56 minutes to administer. Conclusions. The Late-Life Function and Disability Instrument CATs demonstrated strong reliability, validity, accuracy, and precision. The Late-Life Function and Disability Instrument CAT can achieve psychometrically sound disability assessment in older persons while reducing respondent burden. Further research is needed to assess their ability to measure change in older adults. PMID:22546960

  9. Phobos/Harp post launch support

    NASA Technical Reports Server (NTRS)

    Nagy, Andrew

    1993-01-01

    The activity under this grant concentrated on: (1) post-launch calibration of the HARP instrument; and (2) analysis and interpretation of the data from the HARP and other related instruments. The HARP was taken by scientists and engineers from the Hungarian Central Research Institute for Physics (CRIP) to NASA/MSFC for calibration in their plasma chamber, with partial support of this grant. This electron and ion calibration of the HARP, helped in transforming measured currents to actual flux values. The analysis and interpretation of the data, carried out jointly by our Russian and Hungarian colleagues and us, led to a number of journal publications and presentations at scientific meetings.

  10. Mineralogy and Elemental Composition of Wind Drift Soil at Rocknest, Gale Crater

    NASA Technical Reports Server (NTRS)

    Blake, D. F.; Bish, D. L.; Morris, R. V.; Downs, R. T.; Trieman, A. H.; Morrison, S. M.; Chipera, S. J.; Ming, D. W.; Yen, A. S.; Vaniman, D. T.; hide

    2013-01-01

    The Mars Science Laboratory rover Curiosity has been exploring Mars since August 5, 2012, conducting engineering and first-time activities with its mobility system, arm, sample acquisition and processing system (SA/SPaH-CHIMRA) and science instruments. Curiosity spent 54 sols at a location named "Rocknest," collecting and processing five scoops of loose, unconsolidated materials ("soil") acquired from an aeolian bedform (Fig. 1). The Chemistry and Mineralogy (CheMin) instrument analyzed portions of scoops 3, 4, and 5, to obtain the first quantitative mineralogical analysis of Mars soil, and to provide context for Sample Analysis at Mars (SAM) measurements of volatiles, isotopes and possible organic materials.

  11. Relationship between physical activity level and psychosocial and socioeconomic factors and issues in children and adolescents with asthma: a scoping review.

    PubMed

    Westergren, Thomas; Berntsen, Sveinung; Ludvigsen, Mette Spliid; Aagaard, Hanne; Hall, Elisabeth O C; Ommundsen, Yngvar; Uhrenfeldt, Lisbeth; Fegran, Liv

    2017-08-01

    Asthma is a heterogeneous chronic airway disease which may reduce capability for physical activity. In healthy peers, physical activity is influenced by psychosocial and socioeconomic factors. Knowledge about the role of these factors has not been mapped in children and adolescents with asthma. The main objective of this scoping review was to identify psychosocial and socioeconomic factors associated with physical activity level in children and adolescents with asthma in the literature. The specific objectives were to map the instruments used to measure these factors, report on the construction and validation of these instruments, map psychosocial and socioeconomic issues related to physical activity level reported in qualitative studies, and identify gaps in knowledge about the relationship between psychosocial and socioeconomic factors and physical activity level in children and adolescents with asthma. Children and adolescents with asthma aged six to 18 years. Psychosocial and socioeconomic factors related to physical activity level and participation. All physical activity contexts. Quantitative and qualitative primary studies in English, with no date limit. The databases searched included nine major databases for health and sports science, and five databases for unpublished studies. After screening and identification of studies, the reference lists of all identified reports were searched, and forward citation searches were conducted using four databases. The following data were extracted: (a) relevant study characteristics and assessment of physical activity level, (b) instruments used to assess psychosocial and socioeconomic factors, (c) association between physical activity level and these factors, (d) construction and validation of instruments, and (e) psychosocial and socioeconomic issues related to physical activity participation. Twenty-one quantitative and 13 qualitative studies were included. In cross-sectional studies, enjoyment, physical self-concept, self-efficacy, attitudes and beliefs about physical activity and health, psychological distress, health-related quality of life, and social support were more often reported as being correlated with physical activity level. In three studies, the construct validity was assessed by factor analysis and construct reliability tests for the study population. Qualitative studies reported 10 issues related to physical activity participation, and capability and being like peers were most commonly reported. There was no direct evidence that qualitative research informed the development or adjustment of instruments in quantitative studies. Seven psychosocial factors correlated with physical activity level; capability and being like peers were the most commonly reported issues. Reports of the construction and validation of instruments were sparse.

  12. Lightning Instrumentation at KSC

    NASA Technical Reports Server (NTRS)

    Colon, Jose L.; Eng, D.

    2003-01-01

    This report summarizes lightning phenomena with a brief explanation of lightning generation and lightning activity as related to KSC. An analysis of the instrumentation used at launching Pads 39 A&B for measurements of lightning effects is included with alternatives and recommendations to improve the protection system and upgrade the actual instrumentation system. An architecture for a new data collection system to replace the present one is also included. A novel architecture to obtain lightning current information from several sensors using only one high speed recording channel while monitoring all sensors to replace the actual manual lightning current recorders and a novel device for the protection system are described.

  13. The impact of extracurricular activities participation on youth delinquent behaviors: An instrumental variables approach.

    PubMed

    Han, Sehee; Lee, Jonathan; Park, Kyung-Gook

    2017-07-01

    The purpose of this study was to examine the association between extracurricular activities (EA) participation and youth delinquency while tackling an endogeneity problem of EA participation. Using survey data of 12th graders in South Korea (n = 1943), this study employed an instrumental variables approach to address the self-selection problem of EA participation as the data for this study was based on an observational study design. We found a positive association between EA participation and youth delinquency based on conventional regression analysis. By contrast, we found a negative association between EA participation and youth delinquency based on an instrumental variables approach. These results indicate that caution should be exercised when we interpret the effect of EA participation on youth delinquency based on observational study designs. Copyright © 2017 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  14. Evidence on the validity and reliability of the German, French and Italian nursing home version of the Basel Extent of Rationing of Nursing Care instrument.

    PubMed

    Zúñiga, Franziska; Schubert, Maria; Hamers, Jan P H; Simon, Michael; Schwendimann, René; Engberg, Sandra; Ausserhofer, Dietmar

    2016-08-01

    To develop and test psychometrically the Basel Extent of Rationing of Nursing Care for Nursing Homes instrument, providing initial evidence on the validity and reliability of the German, French and Italian-language versions. In the hospital setting, implicit rationing of nursing care is defined as the withholding of nursing activities due to lack of resources, such as staffing or time. No instrument existed to measure this concept in nursing homes. Cross-sectional study. We developed the instrument in three phases: (1) adaption and translation; (2) content validity testing; and (3) initial validity and reliability testing. For phase 3, we analysed survey data from 4748 care workers collected between May 2012-April 2013 from a randomly selected sample of 162 nursing homes in the German-, French- and Italian-speaking regions of Switzerland to provide evidence from response processes (e.g. missing), internal structure (exploratory factor analysis), inter-item inconsistencies (e.g. Cronbach's alpha) and interscorer differences (e.g. within-group agreement). Exploratory factor analysis revealed a four-factor structure with good fit statistics. Rationing of nursing care was structured in four domains: (1) activities of daily living; (2) caring, rehabilitation and monitoring; (3) documentation; and (4) social care. Items of the social care subscale showed lower content validity and more missing values than items of other subscales. First evidence indicates that the new instrument can be recommended for research and practice to measure implicit rationing of nursing care in nursing homes. Further refinements of single items are needed. © 2016 John Wiley & Sons Ltd.

  15. Incorporation of Consumer Products in the Teaching of Analytical Chemistry.

    ERIC Educational Resources Information Center

    Lieu, Van T.; Kalbus, Gene E.

    1988-01-01

    Describes eight experiments involving the use of common consumer products that could be incorporated into quantitative and instrumental analysis laboratories. Discusses these activities in terms of illustration of principles, awareness, and critical thinking. (CW)

  16. Determination and distribution of rare earth elements in beach rock samples using instrumental neutron activation analysis (INAA)

    NASA Astrophysics Data System (ADS)

    Ravisankar, R.; Manikandan, E.; Dheenathayalu, M.; Rao, Brahmaji; Seshadreesan, N. P.; Nair, K. G. M.

    2006-10-01

    Beach rocks are a peculiar type of formation when compared to other types of rocks. Rare earth element (REE) concentrations in beach rock samples collected from the South East Coast of Tamilnadu, India, have been measured using the instrumental neutron activation analysis (INAA) single comparator K0 method. The irradiations were carried out using a thermal neutron flux of ˜10 11 n cm -2 s -1 at 20 kW power using the Kalpakkam mini reactor (KAMINI), IGCAR, Kalpakkam, Tamilnadu. Accuracy and precision were evaluated by assaying irradiated standard reference material (SRM 1646a estuarine sediment). The results being found to be in good agreement with certified values. REE elements have been determined from 15 samples using high-resolution gamma spectrometry. The geochemical behavior of REE in beach rock, in particular REE (chondrite-normalized) pattern has been studied.

  17. Development and psychometric properties of a belief-based Physical Activity Questionnaire for Diabetic Patients (PAQ-DP).

    PubMed

    Ghazanfari, Zeinab; Niknami, Shamsaddin; Ghofranipour, Fazlollah; Hajizadeh, Ebrahim; Montazeri, Ali

    2010-11-09

    This study carried out to develop a scale for assessing diabetic patients' perceptions about physical activity and to test its psychometric properties (The Physical Activity Questionnaire for Diabetic Patients-PAQ-DP). An item pool extracted from the Theory of Planned Behavior literature was generated. Then an expert panel evaluated the items by assessing content validity index and content validity ratio. Consequently exploratory factor analysis (EFA) was performed to indicate the scale constructs. In addition reliability analyses including internal consistency and test-retest analysis were carried out. In all a sample of 127 women with diabetes participated in the study. Twenty-two items were initially extracted from the literature. A six-factor solution (containing 19 items) emerged as a result of an exploratory factor analysis namely: instrumental attitude, subjective norm, perceived behavioral control, affective attitude, self-identity, and intention explaining 60.30% of the variance observed. Additional analyses indicated satisfactory results for internal consistency (Cronbach's alpha ranging from 0.54 to 0.8) and intraclass correlation coefficients (ranging from 0.40 to 0.92). The Physical Activity Questionnaire for Diabetic Patients (PAQ-DP) is the first instrument that applies the Theory of Planned Behavior in its constructs. The findings indicated that the PAQ-DP is a reliable and valid measure for assessing physical activity perceptions and now is available and can be used in future studies.

  18. Development and psychometric properties of a belief-based Physical Activity Questionnaire for Diabetic Patients (PAQ-DP)

    PubMed Central

    2010-01-01

    Background This study carried out to develop a scale for assessing diabetic patients' perceptions about physical activity and to test its psychometric properties (The Physical Activity Questionnaire for Diabetic Patients-PAQ-DP). Methods An item pool extracted from the Theory of Planned Behavior literature was generated. Then an expert panel evaluated the items by assessing content validity index and content validity ratio. Consequently exploratory factor analysis (EFA) was performed to indicate the scale constructs. In addition reliability analyses including internal consistency and test-retest analysis were carried out. Results In all a sample of 127 women with diabetes participated in the study. Twenty-two items were initially extracted from the literature. A six-factor solution (containing 19 items) emerged as a result of an exploratory factor analysis namely: instrumental attitude, subjective norm, perceived behavioral control, affective attitude, self-identity, and intention explaining 60.30% of the variance observed. Additional analyses indicated satisfactory results for internal consistency (Cronbach's alpha ranging from 0.54 to 0.8) and intraclass correlation coefficients (ranging from 0.40 to 0.92). Conclusions The Physical Activity Questionnaire for Diabetic Patients (PAQ-DP) is the first instrument that applies the Theory of Planned Behavior in its constructs. The findings indicated that the PAQ-DP is a reliable and valid measure for assessing physical activity perceptions and now is available and can be used in future studies. PMID:21062466

  19. An instrument to measure job satisfaction of nursing home administrators

    PubMed Central

    Castle, Nicholas G

    2006-01-01

    Background The psychometric properties of the nursing home administrator job satisfaction questionnaire (NHA-JSQ) are presented, and the steps used to develop this instrument. Methods The NHA-JSQ subscales were developed from pilot survey activities with 93 administrators, content analysis, and a research panel. The resulting survey was sent to 1,000 nursing home administrators. Factor analyses were used to determine the psychometric properties of the instrument. Results Of the 1,000 surveys mailed, 721 usable surveys were returned (72 percent response rate). The factor analyses show that the items were representative of six underlying factors (i.e., coworkers, work demands, work content, work load, work skills, and rewards). Conclusion The NHA-JSQ represents a short, psychometrically sound job satisfaction instrument for use in nursing homes. PMID:17029644

  20. Department of Defense In-House RDT&E Activities

    DTIC Science & Technology

    1984-10-30

    PRODUCTION. QC & NOT EQUIPMENT, ULTRASONICS, XRAY & NEUTRON RADIOGRAPHY , SPECTROSCOPY, HOLOGRAPHY, CHEMICAL ANALYSIS, METALLOGRAPTY & OPTICS. OTHER:U & BE...IMPORTANT PROGRAMS OTNl1O9A XM40 MASK OTNI033 RADAR WARNING RECEIVER AN/APR-39A 0TN966 AIRCREW SURVIVAL VEST 0TN876 SELF- PROPELLED ELEVATED MAINTENANCE...FACILITY FOR PROPELLANT FLAME ANALYSIS; COMPUTED TOMOGRAPHY FOR BALLISTIC EVENTS; PROPELLANT FRACTURE MECHANICS ANALYSIS FACILITY; INSTRUMENTED INDOOR

  1. Analysis of temperature rise and the use of coolants in the dissipation of ultrasonic heat buildup during post removal.

    PubMed

    Davis, Stephen; Gluskin, Alan H; Livingood, Philip M; Chambers, David W

    2010-11-01

    This study was designed to calculate probabilities for tissue injury and to measure effectiveness of various coolant strategies in countering heat buildup produced by dry ultrasonic vibration during post removal. A simulated biological model was used to evaluate the cooling efficacy of a common refrigerant spray, water spray, and air spray in the recovery of post temperatures deep within the root canal space. The data set consisted of cervical and apical measures of temperature increase at 1-second intervals from baseline during continuous ultrasonic instrumentation until a 10 °C increase in temperature at the cervical site was registered, wherein instrumentation ceased, and the teeth were allowed to cool under ambient conditions or with the assistance of 4 coolant methods. Data were analyzed with analysis of variance by using the independent variables of time of ultrasonic application (10, 15, 20 seconds) and cooling method. In addition to the customary means, standard deviations, and analysis of variance tests, analyses were conducted to determine probabilities that procedures would reach or exceed the 10 °C threshold. Both instrumentation time and cooling agent effects were significant at P <.0001. Under the conditions of this study, it was shown that injurious heat transfer occurs in less than 1 minute during dry ultrasonic instrumentation of metallic posts. Cycles of short instrumentation times with active coolants were effective in reducing the probability of tissue damage when teeth were instrumented dry. With as little as 20 seconds of continuous dry ultrasonic instrumentation, the consequences of thermal buildup to an individual tooth might contribute to an injurious clinical outcome. Copyright © 2010 American Association of Endodontists. All rights reserved.

  2. Validation of an instrument to evaluate health promotion at schools

    PubMed Central

    Pinto, Raquel Oliveira; Pattussi, Marcos Pascoal; Fontoura, Larissa do Prado; Poletto, Simone; Grapiglia, Valenca Lemes; Balbinot, Alexandre Didó; Teixeira, Vanessa Andina; Horta, Rogério Lessa

    2016-01-01

    ABSTRACT OBJECTIVE To validate an instrument designed to assess health promotion in the school environment. METHODS A questionnaire, based on guidelines from the World Health Organization and in line with the Brazilian school health context, was developed to validate the research instrument. There were 60 items in the instrument that included 40 questions for the school manager and 20 items with direct observations made by the interviewer. The items’ content validation was performed using the Delphi technique, with the instrument being applied in 53 schools from two medium-sized cities in the South region of Brazil. Reliability (Cronbach’s alpha and split-half) and validity (principal component analysis) analyses were performed. RESULTS The final instrument remained composed of 28 items, distributed into three dimensions: pedagogical, structural and relational. The resulting components showed good factorial loads (> 0.4) and acceptable reliability (> 0.6) for most items. The pedagogical dimension identifies educational activities regarding drugs and sexuality, violence and prejudice, auto care and peace and quality of life. The structural dimension is comprised of access, sanitary structure, and conservation and equipment. The relational dimension includes relationships within the school and with the community. CONCLUSIONS The proposed instrument presents satisfactory validity and reliability values, which include aspects relevant to promote health in schools. Its use allows the description of the health promotion conditions to which students from each educational institution are exposed. Because this instrument includes items directly observed by the investigator, it should only be used during periods when there are full and regular activities at the school in question. PMID:26982958

  3. Analysis of standard reference materials by absolute INAA

    NASA Astrophysics Data System (ADS)

    Heft, R. E.; Koszykowski, R. F.

    1981-07-01

    Three standard reference materials: flyash, soil, and ASI 4340 steel, are analyzed by a method of absolute instrumental neutron activation analysis. Two different light water pool-type reactors were used to produce equivalent analytical results even though the epithermal to thermal flux ratio in one reactor was higher than that in the other by a factor of two.

  4. Simultaneous collection of airborne particulate matter on several collection substrates with a high-volume cascade impactor

    NASA Astrophysics Data System (ADS)

    Chan, Y. C.; Vowles, P. D.; McTainsh, G. H.; Simpson, R. W.; Cohen, D. D.; Bailey, G. M.; McOrist, G. D.

    This paper describes a method for the simultaneous collection of size-fractionated aerosol samples on several collection substrates, including glass-fibre filter, carbon tape and silver tape, with a commercially available high-volume cascade impactor. This permitted various chemical analysis procedures, including ion beam analysis (IBA), instrumental neutron activation analysis (INAA), carbon analysis and scanning electron microscopy (SEM), to be carried out on the samples.

  5. An ontology-based exploration of the concepts and relationships in the activities and participation component of the international classification of functioning, disability and health.

    PubMed

    Della Mea, Vincenzo; Simoncello, Andrea

    2012-02-28

    The International Classification of Functioning, Disability and Health (ICF) is a classification of health and health-related issues, aimed at describing and measuring health and disability at both individual and population levels. Here we discuss a preliminary qualitative and quantitative analysis of the relationships used in the Activities and Participation component of ICF, and a preliminary mapping to SUMO (Suggested Upper Merged Ontology) concepts. The aim of the analysis is to identify potential logical problems within this component of ICF, and to understand whether activities and participation might be defined more formally than in the current version of ICF. In the relationship analysis, we used four predicates among those available in SUMO for processes (Patient, Instrument, Agent, and subProcess). While at the top level subsumption was used in most cases (90%), at the lower levels the percentage of other relationships rose to 41%. Chapters were heterogeneous in the relationships used and some of the leaves of the tree seemed to represent properties or parts of the parent concept rather than subclasses. Mapping of ICF to SUMO proved partially feasible, with the activity concepts being mapped mostly (but not totally) under the IntentionalProcess concept in SUMO. On the other hand, the participation concept has not been mapped to any upper level concept. Our analysis of the relationships within ICF revealed issues related to confusion between classes and their properties, incorrect classifications, and overemphasis on subsumption, confirming what already observed by other researchers. However, it also suggested some properties for Activities that could be included in a more formal model: number of agents involved, the instrument used to carry out the activity, the object of the activity, complexity of the task, and an enumeration of relevant subtasks.

  6. Analysing exoplanetary data using unsupervised machine-learning

    NASA Astrophysics Data System (ADS)

    Waldmann, I. P.

    2012-04-01

    The field of transiting extrasolar planets and especially the study of their atmospheres is one of the youngest and most dynamic subjects in current astrophysics. Permanently at the edge of technical feasibility, we are successfully discovering and characterising smaller and smaller planets. To study exoplanetary atmospheres, we typically require a 10-4 to 10-5 level of accuracy in flux. Achieving such a precision has become the central challenge to exoplanetary research and is often impeded by systematic (nongaussian) noise from either the instrument, stellar activity or both. Dedicated missions, such as Kepler, feature an a priori instrument calibration plan to the required accuracy but nonetheless remain limited by stellar systematics. More generic instruments often lack a sufficiently defined instrument response function, making it very hard to calibrate. In these cases, it becomes interesting to know how well we can calibrate the data without any additional or prior knowledge of the instrument or star. In this conference, we present a non-parametric machine-learning algorithm, based on the concept of independent component analysis, to de-convolve the systematic noise and all non-Gaussian signals from the desired astrophysical signal. Such a 'blind' signal de-mixing is commonly known as the 'Cocktail Party problem' in signal-processing. We showcase the importance and broad applicability of unsupervised machine learning in exoplanetary data analysis by discussing: 1) the removal of instrument systematics in a re-analysis of an HD189733b transmission spectrum obtained with Hubble/NICMOS; 2) the removal of time-correlated stellar noise in individual lightcurves observed by the Kepler mission.

  7. Time-location analysis for exposure assessment studies of children using a novel global positioning system instrument.

    PubMed Central

    Elgethun, Kai; Fenske, Richard A; Yost, Michael G; Palcisko, Gary J

    2003-01-01

    Global positioning system (GPS) technology is used widely for business and leisure activities and offers promise for human time-location studies to evaluate potential exposure to environmental contaminants. In this article we describe the development of a novel GPS instrument suitable for tracking the movements of young children. Eleven children in the Seattle area (2-8 years old) wore custom-designed data-logging GPS units integrated into clothing. Location data were transferred into geographic information systems software for map overlay, visualization, and tabular analysis. Data were grouped into five location categories (in vehicle, inside house, inside school, inside business, and outside) to determine time spent and percentage reception in each location. Additional experiments focused on spatial resolution, reception efficiency in typical environments, and sources of signal interference. Significant signal interference occurred only inside concrete/steel-frame buildings and inside a power substation. The GPS instruments provided adequate spatial resolution (typically about 2-3 m outdoors and 4-5 m indoors) to locate subjects within distinct microenvironments and distinguish a variety of human activities. Reception experiments showed that location could be tracked outside, proximal to buildings, and inside some buildings. Specific location information could identify movement in a single room inside a home, on a playground, or along a fence line. The instrument, worn in a vest or in bib overalls, was accepted by children and parents. Durability of the wiring was improved early in the study to correct breakage problems. The use of GPS technology offers a new level of accuracy for direct quantification of time-location activity patterns in exposure assessment studies. PMID:12515689

  8. Dynamics-A explorer RIMS data analysis

    NASA Technical Reports Server (NTRS)

    Banks, P. M.; Clauer, C. R.

    1985-01-01

    Activities of the RIMS instrument during the extended mission are planned. The modes of operation for RIMS to achieve the science requirements utilizing the new and exciting information on the composition and dynamics of the low energy (0-50eV) ions in the Earth's ionosphere and magnetosphere are determined. The specific science problems and the required RIMS operational modes needed to acquire the desired data are identified. The analysis was performed on the RIMS data to achieve the science results and this new information was used in determining RIMS operations during the latter part of the mission. Necessary sensitivity tests of RIMS operating modes and instrument performance was suggested. The inflight results was compared with theoretical models.

  9. Determination of silicon in biological and botanical reference materials by epithermal INAA and Compton suppression

    NASA Astrophysics Data System (ADS)

    Landsberger, S.; Peshev, S.; Becker, D. A.

    1994-12-01

    Silicon determination in sixteen botanical and biological standard reference materials is described using the 29Si(n, p) 29Al reaction through instrumental epithermal neutron activation analysis and Compton suppression gamma-ray spectroscopy. By simultaneous utilization of both cadmium and boron epithermal filters along with anticoincidence gamma-counting, detection limits as low as 12 ppm were obtained for certain matrices, much lower than previously reported values for this type of analysis. The method is applicable to many botanical and biological matrices and is attractive with its interference free, purely instrumental nature, compared with methods using the 28Si(n, p) 28Al reaction or chemical separation techniques.

  10. Compact Microwave Fourier Spectrum Analyzer

    NASA Technical Reports Server (NTRS)

    Savchenkov, Anatoliy; Matsko, Andrey; Strekalov, Dmitry

    2009-01-01

    A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

  11. Cosmic ray composition investigations using ICE/ISEE-3

    NASA Technical Reports Server (NTRS)

    Wiedenbeck, Mark E.

    1992-01-01

    The analysis of data from the high energy cosmic experiment on ISEE-3 and associated modeling and interpretation activities are discussed. The ISEE-3 payload included two instruments capable of measuring the composition of heavy cosmic rays. The designs of these two instruments incorporated innovations which made it possible, for the first time, to measure isotopic as well as the chemical composition for a wide range of elements. As the result of the demonstrations by these two instruments of the capability to resolve individual cosmic ray isotopes, a new generation of detectors was developed using very similar designs, but having improved reliability and increased sensitive area. The composition measurements which were obtained from the ISEE-3 experiment are summarized.

  12. Physical activity measurement instruments for children with cerebral palsy: a systematic review.

    PubMed

    Capio, Catherine M; Sit, Cindy H P; Abernethy, Bruce; Rotor, Esmerita R

    2010-10-01

    this paper is a systematic review of physical activity measurement instruments for field-based studies involving children with cerebral palsy (CP). database searches using PubMed Central, MEDLINE, CINAHL Plus, PsycINFO, EMBASE, Cochrane Library, and PEDro located 12 research papers, identifying seven instruments that met the inclusion criteria of (1) having been developed for children aged 0 to 18 years, (2) having been used to evaluate a physical activity dimension, and (3) having been used in a field-based study involving children with CP. The instruments reviewed were the Activities Scale for Kids - Performance version (ASKp), the Canada Fitness Survey, the Children's Assessment of Participation and Enjoyment/Preferences for Activities of Children (CAPE/PAC), the Compendium of Physical Activities, the Physical Activity Questionnaire - Adolescents (PAQ-A), StepWatch, and the Uptimer. Second-round searches yielded 11 more papers, providing reliability and validity evidence for the instruments. the instruments measure physical activity frequency, mode, domain, and duration. Although most instruments demonstrated adequate reliability and validity, only the ASKp and CAPE/PAC have established reliability and validity for children with physical disabilities; the Uptimer has established concurrent validity. No instrument measuring intensity in free-living has been validated or found reliable for children with CP. the findings suggest that further studies are needed to examine the methodological properties of physical activity measurement in children with CP. Combining subjective and objective instruments is recommended to achieve better understanding of physical activity participation.

  13. Development and initial evaluation of an instrument to assess physiotherapists' clinical reasoning focused on clients' behavior change.

    PubMed

    Elvén, Maria; Hochwälder, Jacek; Dean, Elizabeth; Söderlund, Anne

    2018-05-01

    A systematically developed and evaluated instrument is needed to support investigations of physiotherapists' clinical reasoning integrated with the process of clients' behavior change. This study's aim was to develop an instrument to assess physiotherapy students' and physiotherapists' clinical reasoning focused on clients' activity-related behavior and behavior change, and initiate its evaluation, including feasibility and content validity. The study was conducted in three phases: 1) determination of instrument structure and item generation, based on a model, guidelines for assessing clinical reasoning, and existing measures; 2) cognitive interviews with five physiotherapy students to evaluate item understanding and feasibility; and 3) a Delphi process with 18 experts to evaluate content relevance. Phase 1 resulted in an instrument with four domains: Physiotherapist; Input from client; Functional behavioral analysis; and Strategies for behavior change. The instrument consists of case scenarios followed by items in which key features are identified, prioritized, or interpreted. Phase 2 resulted in revisions of problems and approval of feasibility. Phase 3 demonstrated high level of consensus regarding the instrument's content relevance. This feasible and content-validated instrument shows potential for use in investigations of physiotherapy students' and physiotherapists' clinical reasoning, however continued development and testing are needed.

  14. Depression and Daydreaming: An Analysis Based on Self-Ratings

    ERIC Educational Resources Information Center

    Giambra, Leonard M.; Traynor, Thomas D.

    1978-01-01

    Investigated the relationship between depression and daydreaming characteristics in a non-hospitalized sample. Use was made of self-report psychometric instruments that measure depression and aspects of depression and other activity such as mindwandering, boredom, distractibility, and curiosity. (Editor/RK)

  15. Analytical techniques and instrumentation: A compilation

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Technical information on developments in instrumentation is arranged into four sections: (1) instrumentation for analysis; (2) analysis of matter; (3) analysis of electrical and mechanical phenomena; and (4) structural analysis. Patent information for two of the instruments described is presented.

  16. The N2N instrument to evaluate healthy work environments: an Italian validation.

    PubMed

    Palese, Alvisa; Dante, Angelo; Tonzar, Laura; Balboni, Bernardo

    2014-02-01

    The aims of the study were to (a) validate N2N Healthy Work Environment tool, (b) assess the healthiness of work environments as perceived by nurses themselves and (c) identify the factors associated with Italian nurses' perception of work environment healthiness. The linguistic and cultural adaptation of USA-N2N Healthy Work Environments was achieved through a process of forward/backward translation. Content validity was assessed by three expert nurses. The stability of the instrument was checked with a test/retest evaluation. The instrument psychometric properties, the confirmatory factor analysis as well the healthiness of the work environment and its determinant factors were evaluated with a sample of 294 nurses. The content and face validity of the N2N Healthy Work Environment instrument was confirmed. The instrument demonstrated good internal consistency (α of 0.82), excellent stability values (ρ > 0.70) and high levels of acceptability (response rate: 96.4 %). The confirmatory factor analysis has corroborated the existence of two factors as documented in the original instrument (Mays et al. in J Nurs Manag 19:18-26, 2011). Eighty-seven (29.6 %) nurses perceived the work environment where they work as "healthy". Working under a functional model of care delivery (χ(2) 24.856, p 0.000) and being responsible for one project or more (χ(2) 5.256, p 0.021) were associated with healthy environments. The instrument--valid and reliable, short in the number of items, easy to understand and based on international standards--allows a systematic assessment of the healthiness of the environment and might provide not only the opportunity to evaluate the effects of new organizational models and interventions, but also the possibility to activate a process of self-analysis and a process of ongoing review. The instrument can be used to systematically check the healthiness of Italian working environments, allowing for organizational diagnosis, targeted interventions and international comparisons.

  17. Corongraphic Observations and Analyses of The Ultraviolet Solar Corona

    NASA Technical Reports Server (NTRS)

    Kohl, John L.

    2000-01-01

    The activities supported under NASA Grant NAG5-613 included the following: 1) reduction and scientific analysis of data from three sounding rocket flights of the Rocket Ultraviolet Coronagraph Spectrometer, 2) development of ultraviolet spectroscopic diagnostic techniques to provide a detailed empirical description of the extended solar corona, 3) extensive upgrade of the rocket instrument to become the Ultraviolet Coronal Spectrometer (UVCS) for Spartan 201,4) instrument scientific calibration and characterization, 5) observation planning and mission support for a series of five Spartan 201 missions (fully successful except for STS 87 where the Spartan spacecraft was not successfully deployed and the instruments were not activated), and 6) reduction and scientific analysis of the UVCS/Spartan 201 observational data. The Ultraviolet Coronal Spectrometer for Spartan 201 was one unit of a joint payload and the other unit was a White Light Coronagraph (WLC) provided by the High Altitude Observatory and the Goddard Space Flight Center. The two instruments were used in concert to determine plasma parameters describing structures in the extended solar corona. They provided data that could be used individually or jointly in scientific analyses. The WLC provided electron column densities in high spatial resolution and high time resolution. UVCS/Spartan provided hydrogen velocity distributions, and line of sight hydrogen velocities. The hydrogen intensities from UVCS together with the electron densities from WLC were used to determine hydrogen outflow velocities. The UVCS also provided O VI intensities which were used to develop diagnostics for velocity distributions and outflow velocities of minor ions.

  18. Instrument for evaluation of sedentary lifestyle in patients with high blood pressure.

    PubMed

    Lopes, Marcos Venícios de Oliveira; da Silva, Viviane Martins; de Araujo, Thelma Leite; Guedes, Nirla Gomes; Martins, Larissa Castelo Guedes; Teixeira, Iane Ximenes

    2015-01-01

    this article describes the diagnostic accuracy of the International Physical Activity Questionnaire to identify the nursing diagnosis of sedentary lifestyle. a diagnostic accuracy study was developed with 240 individuals with established high blood pressure. The analysis of diagnostic accuracy was based on measures of sensitivity, specificity, predictive values, likelihood ratios, efficiency, diagnostic odds ratio, Youden index, and area under the receiver-operating characteristic curve. statistical differences between genders were observed for activities of moderate intensity and for total physical activity. Age was negatively correlated with activities of moderate intensity and total physical activity. the analysis of area under the receiver-operating characteristic curve for moderate intensity activities, walking, and total physical activity showed that the International Physical Activity Questionnaire present moderate capacity to correctly classify individuals with and without sedentary lifestyle.

  19. Bringing the light to high throughput screening: use of optogenetic tools for the development of recombinant cellular assays

    NASA Astrophysics Data System (ADS)

    Agus, Viviana; Di Silvio, Alberto; Rolland, Jean Francois; Mondini, Anna; Tremolada, Sara; Montag, Katharina; Scarabottolo, Lia; Redaelli, Loredana; Lohmer, Stefan

    2015-03-01

    The use of light-activated proteins represents a powerful tool to control biological processes with high spatial and temporal precision. These so called "optogenetic" technologies have been successfully validated in many recombinant systems, and have been widely applied to the study of cellular mechanisms in intact tissues or behaving animals; to do that, complex, high-intensity, often home-made instrumentations were developed to achieve the optimal power and precision of light stimulation. In our study we sought to determine if this optical modulation can be obtained also in a miniaturized format, such as a 384-well plate, using the instrumentations normally dedicated to fluorescence analysis in High Throughput Screening (HTS) activities, such as for example the FLIPR (Fluorometric Imaging Plate Reader) instrument. We successfully generated optogenetic assays for the study of different ion channel targets: the CaV1.3 calcium channel was modulated by the light-activated Channelrhodopsin-2, the HCN2 cyclic nucleotide gated (CNG) channel was modulated by the light activated bPAC adenylyl cyclase, and finally the genetically encoded voltage indicator ArcLight was efficiently used to measure potassium, sodium or chloride channel activity. Our results showed that stable, robust and miniaturized cellular assays can be developed using different optogenetic tools, and efficiently modulated by the FLIPR instrument LEDs in a 384-well format. The spatial and temporal resolution delivered by this technology might enormously advantage the early stages of drug discovery, leading to the identification of more physiological and effective drug molecules.

  20. Superconducting gravimeters reveal unprecedented details of changes related to volcanic processes

    NASA Astrophysics Data System (ADS)

    Carbone, Daniele; Greco, Filippo; Cannavò, Flavio

    2017-04-01

    Continuous gravity measurements have been successfully carried out at a number of volcanoes around the world using spring gravimeters. Nevertheless, these instruments do not provide reliable measurements when used in continuous mode for weeks or more, because they are influenced by environmental factors and are subject to instrumental drift. Accordingly, most studies of continuous gravity at active volcanoes have focused on the analysis of changes over time-scales of minutes to a few days. An alternative to spring gravimeters for continuous measurements is given by superconducting gravimeters (SGs) that feature a much higher precision and stability than spring gravimeters. However, even the most portable SGs (e.g., the iGrav® by GWR) are not ideal for installation in the vicinity of active volcanic structures. Indeed, they require AC power at the installation site and some kind of hut or vault to house the instrumentation. At Mt. Etna, the installation of a mini-array of three SGs (distances of 3.5 to 15.5 km from the active craters) was begun in September 2014. To our knowledge, these are the first SGs ever installed on an active volcano. Signals from these instruments show hydrologically-induced components superimposed on small (a few microGal) gravity changes that are related to volcanic processes. Such changes, occurring over periods of minutes to weeks, would not be observable by spring gravimeters due to their intrinsic limitations regarding precision and long-term stability.

  1. Development of a simple 12-item theory-based instrument to assess the impact of continuing professional development on clinical behavioral intentions.

    PubMed

    Légaré, France; Borduas, Francine; Freitas, Adriana; Jacques, André; Godin, Gaston; Luconi, Francesca; Grimshaw, Jeremy

    2014-01-01

    Decision-makers in organizations providing continuing professional development (CPD) have identified the need for routine assessment of its impact on practice. We sought to develop a theory-based instrument for evaluating the impact of CPD activities on health professionals' clinical behavioral intentions. Our multipronged study had four phases. 1) We systematically reviewed the literature for instruments that used socio-cognitive theories to assess healthcare professionals' clinically-oriented behavioral intentions and/or behaviors; we extracted items relating to the theoretical constructs of an integrated model of healthcare professionals' behaviors and removed duplicates. 2) A committee of researchers and CPD decision-makers selected a pool of items relevant to CPD. 3) An international group of experts (n = 70) reached consensus on the most relevant items using electronic Delphi surveys. 4) We created a preliminary instrument with the items found most relevant and assessed its factorial validity, internal consistency and reliability (weighted kappa) over a two-week period among 138 physicians attending a CPD activity. Out of 72 potentially relevant instruments, 47 were analyzed. Of the 1218 items extracted from these, 16% were discarded as improperly phrased and 70% discarded as duplicates. Mapping the remaining items onto the constructs of the integrated model of healthcare professionals' behaviors yielded a minimum of 18 and a maximum of 275 items per construct. The partnership committee retained 61 items covering all seven constructs. Two iterations of the Delphi process produced consensus on a provisional 40-item questionnaire. Exploratory factorial analysis following test-retest resulted in a 12-item questionnaire. Cronbach's coefficients for the constructs varied from 0.77 to 0.85. A 12-item theory-based instrument for assessing the impact of CPD activities on health professionals' clinical behavioral intentions showed adequate validity and reliability. Further studies could assess its responsiveness to behavior change following CPD activities and its capacity to predict health professionals' clinical performance.

  2. Development of a Simple 12-Item Theory-Based Instrument to Assess the Impact of Continuing Professional Development on Clinical Behavioral Intentions

    PubMed Central

    Légaré, France; Borduas, Francine; Freitas, Adriana; Jacques, André; Godin, Gaston; Luconi, Francesca; Grimshaw, Jeremy

    2014-01-01

    Background Decision-makers in organizations providing continuing professional development (CPD) have identified the need for routine assessment of its impact on practice. We sought to develop a theory-based instrument for evaluating the impact of CPD activities on health professionals' clinical behavioral intentions. Methods and Findings Our multipronged study had four phases. 1) We systematically reviewed the literature for instruments that used socio-cognitive theories to assess healthcare professionals' clinically-oriented behavioral intentions and/or behaviors; we extracted items relating to the theoretical constructs of an integrated model of healthcare professionals' behaviors and removed duplicates. 2) A committee of researchers and CPD decision-makers selected a pool of items relevant to CPD. 3) An international group of experts (n = 70) reached consensus on the most relevant items using electronic Delphi surveys. 4) We created a preliminary instrument with the items found most relevant and assessed its factorial validity, internal consistency and reliability (weighted kappa) over a two-week period among 138 physicians attending a CPD activity. Out of 72 potentially relevant instruments, 47 were analyzed. Of the 1218 items extracted from these, 16% were discarded as improperly phrased and 70% discarded as duplicates. Mapping the remaining items onto the constructs of the integrated model of healthcare professionals' behaviors yielded a minimum of 18 and a maximum of 275 items per construct. The partnership committee retained 61 items covering all seven constructs. Two iterations of the Delphi process produced consensus on a provisional 40-item questionnaire. Exploratory factorial analysis following test-retest resulted in a 12-item questionnaire. Cronbach's coefficients for the constructs varied from 0.77 to 0.85. Conclusion A 12-item theory-based instrument for assessing the impact of CPD activities on health professionals' clinical behavioral intentions showed adequate validity and reliability. Further studies could assess its responsiveness to behavior change following CPD activities and its capacity to predict health professionals' clinical performance. PMID:24643173

  3. INTRODUCTION TO THE USE OF THE COPING ANALYSIS SCHEDULE FOR EDUCATIONAL SETTINGS (CASES) AND THE SPAULDING TEACHER ACTIVITY RATING SCHEDULE (STARS).

    ERIC Educational Resources Information Center

    SPAULDING, ROBERT L.

    THIS BOOKLET INTRODUCES TWO MEASUREMENT INSTRUMENTS FOCUSING ON CLASS MANAGEMENT. THE COPING ANALYSIS SCHEDULE FOR EDUCATIONAL SETTINGS PERMITS THE CODIFICATION OF ALL OPERANT BEHAVIOR OBSERVED IN THE CLASSROOM, INTO ONE OF THIRTEEN CATEGORIES. ALL BUT ONE OF THE THIRTEEN CATEGORIES ARE DESIGNED TO CHARACTERIZE THE CHILD'S ECONOMY WITH THE…

  4. Wavelet analysis of stellar differential rotation. III. The Sun in white light

    NASA Astrophysics Data System (ADS)

    Hempelmann, A.

    2003-02-01

    Future space projects like KEPLER will deliver a vast quantity of high precision light curves of stars. This paper describes a test concerning the observability of rotation and even differential rotation of slowly rotating stars from such data. Two published light curves of solar total irradiance measures are investigated: the Nimbus-7 Earth Radiation Budget (ERB) observations between 1978 and 1993 and the Active Cavity Radiometer Irradiance Monitor I (ACRIM I) measurements between 1980 and 1989. Light curve analysis show that oscillations on time-scales comparable to solar rotation but of a complex pattern are visible. Neither Fourier analysis nor time-frequency Wavelet analysis yield the true rotation period during the more active phases of the solar cycle. The true rotation period dominates only for a short time during solar minimum. In the light of this study even space-born broad band photometry may turn out an inappropriate instrument to study stellar butterfly diagrams of stars rotating as slow as the Sun. However, it was shown in Papers I and II of this series that chromospheric tracers like Lyman alpha , Mg II h+k and CaII H+K are appropriate instruments to perform this task.

  5. The Planned Soil Moisture Active Passive (SMAP) Mission L-Band Radar/Radiometer Instrument

    NASA Technical Reports Server (NTRS)

    Spencer, Michael; Wheeler, Kevin; Chan, Samuel; Piepmeier, Jeffrey; Hudson, Derek; Medeiros, James

    2011-01-01

    The Soil Moisture Active/Passive (SMAP) mission is a NASA mission identified by the NRC 'decadal survey' to measure both soil moisture and freeze/thaw state from space. The mission will use both active radar and passive radiometer instruments at L-Band. In order to achieve a wide swath at sufficiently high resolution for both active and passive channels, an instrument architecture that uses a large rotating reflector is employed. The instrument system has completed the preliminary design review (PDR) stage, and detailed instrument design has begun. In addition to providing an overview of the instrument design, two recent design modifications are discussed: 1) The addition of active thermal control to the instrument spun side to provide a more stable, settable thermal environment for the radiometer electronics, and 2) A 'sequential transmit' strategy for the two radar polarization channels which allows a single high-power amplifier to be used.

  6. Soil moisture mapping for aquarius

    USDA-ARS?s Scientific Manuscript database

    Aquarius is the first satellite to provide both passive and active L-band observations of the Earth. In addition, the instruments on Satelite de Aplicaciones Cientificas-D (SAC-D) provide complementary information for analysis and retrieval algorithms. Our research focuses on the retrieval of soil m...

  7. [Approaches to medical training among physicians who teach; analysis of two different educational strategies].

    PubMed

    Loría-Castellanos, Jorge; Rivera-lbarra, Doris Beatriz; Márquez-Avila, Guadalupe

    2009-01-01

    Compare the outreach of a promotional educational strategy that focuses on active participation and compare it with a more traditional approach to medical training. A quasi-experimental design was approved by the research committee. We compared the outreach of two different approaches to medical training. We administered a validated instrument that included 72 items that analyze statements used to measure educational tasks in the form of duplets through 3 indicators. A group that included seven physicians that were actively participating in teaching activities was stratified according to teaching approaches. One of the approaches was a traditional one and the other included a promotional strategy aimed at increasing participation. All participants signed informed consent before answering the research instruments. Statistical analysis was done using non-parametric tests. Mann-Whitney results did not show differences among the group in the preliminary analysis. A second analysis with the same test after the interventions found significant differences (p d" 0.018) in favor of those subjects that had participated in the promotional approach mainly in the indicator measuring "consequence". The Wilcoxon test showed that all participants in the promotional approach increased significantly (pd" 0.018) in 3 main indicators as compared with the control group. A promotional strategy aimed at increasing physician participation constitutes a more profitable approach when compared with traditional teaching methods.

  8. Instruments for Planetary Exploration with CubeSats and SmallSats

    NASA Astrophysics Data System (ADS)

    Raymond, Carol; Jaumann, Ralf; Vane, Gregg; Baker, John; Castillo-Rogez, Julie; Yano, Hajime

    2016-07-01

    Planetary sensors and instruments are undergoing a revolutionary transformation as solid-state electronics and advanced detectors allow drastic reductions in size, mass and power relative to instruments flown in the past. Given their reduced resource needs, these capable new systems are potentially compatible with use on smallsats. New built-in processing techniques further enable increased science return in constrained resource environments. In the summer of 2014 an international group of scientists, engineers, and technologists started a study to define investigations to be carried out by nano-spacecraft, and instruments that would enable breakthrough science from these small platforms were identified. The possibilities include passive remote sensing instruments such as imagers, spectrometers, magnetometers, dust analyzers; active instruments such as radar, lidar, laser-induced breakdown spectroscopy (LIBS), muonography, projectiles; and landed packages and in-situ probes such as instrumented penetrators, seismometers, and in-situ sample analysis packages. Many of the passive and active instruments could be used in-situ for very high-resolution measurements over limited areas. Smallsats lend themselves to observing strategies that allow dense spatial and temporal sampling using multiple flight system elements, covering a range of observing conditions, and multi-scale measurements with concurrent surface and remote observations. The lower cost of smallsats allows visiting a large range of targets and provides an architecture for cooperating distributed networks of sensors. The current state-of-the-art in smallsat payloads includes instrument suites on the Philae lander (Rosetta), and the MINERVA-II rovers and MASCOT on Hayabusa-2. Many Cubesat form factor instruments are either built or in development, including impactors and penetrators, and several new technologies are making their debut in the smallsat arena. The Philae payload included the CONSERT active radar experiment, MUPUS hammer and heat flow probes, magnetometer, ROLIS cameras and ROSINA mass spectrometer. MASCOT carries MicrOmega (NIR spectrometer), magnetometer, camera, and radiometer. The INSPIRE Cubesat mission carries a 1/2U Vector Helium Magnetometer. An intelligent camera maturing for flight in 2018 on the NEA Scout Cubesat mission promises to deliver a low-cost dual-use navigation and science capability at Cubesat scale. Cubesat versions of VIS-IR imaging spectrometers, neutron and gamma-ray spectrometers, mass spectrometers, tunable laser diode spectrometer and active radar are under development. Acknowledgements: This study is sponsored by the International Academy of Astronautics (IAA). Part of this work is being carried out at the Jet Propulsion Lab, California Institute of Technology, under contract to NASA.

  9. OISI dynamic end-to-end modeling tool

    NASA Astrophysics Data System (ADS)

    Kersten, Michael; Weidler, Alexander; Wilhelm, Rainer; Johann, Ulrich A.; Szerdahelyi, Laszlo

    2000-07-01

    The OISI Dynamic end-to-end modeling tool is tailored to end-to-end modeling and dynamic simulation of Earth- and space-based actively controlled optical instruments such as e.g. optical stellar interferometers. `End-to-end modeling' is meant to denote the feature that the overall model comprises besides optical sub-models also structural, sensor, actuator, controller and disturbance sub-models influencing the optical transmission, so that the system- level instrument performance due to disturbances and active optics can be simulated. This tool has been developed to support performance analysis and prediction as well as control loop design and fine-tuning for OISI, Germany's preparatory program for optical/infrared spaceborne interferometry initiated in 1994 by Dornier Satellitensysteme GmbH in Friedrichshafen.

  10. Neutron activation analysis on the surface of the Moon and other terrestrial planets

    NASA Astrophysics Data System (ADS)

    Golovin, Dmitry; Litvak, Maxim; Kozyrev, S. Alexander; Tretiyakov, Vladislav; Sanin, Anton; Vostrukhin, Andrey; Mitrofanov, Igor; Malakhov, Alexey

    Determine of elements composition of the planet subsurface in situ is important scientific task for understanding of origin and formation processes of terrestrial planets, moons and asteroids. Also this study will be very perspective in terms of utilization of mineral resources for future lunar base. Creation of such outpost will open doors for robotic and human exploration in the distant parts of Solar System. ADRON instrument onboard landing platforms Russian near-pole lunar missions (Glob and Resource) will be first example of using Neutron Activation method in space. It will measure nuclear composition of the lunar regolith in the landing sites up to 1 m depth. This instrument is able to use for different planets and conditions. For Venus surface, taking into account short lifetime of spacecraft one or two hours of operation will be enough to perform such measurements. Another good opportunity is using similar instrument on Lunar or Martian rovers for searching of important minerals.

  11. Standard-less analysis of Zircaloy clad samples by an instrumental neutron activation method

    NASA Astrophysics Data System (ADS)

    Acharya, R.; Nair, A. G. C.; Reddy, A. V. R.; Goswami, A.

    2004-03-01

    A non-destructive method for analysis of irregular shape and size samples of Zircaloy has been developed using the recently standardized k0-based internal mono standard instrumental neutron activation analysis (INAA). The samples of Zircaloy-2 and -4 tubes, used as fuel cladding in Indian boiling water reactors (BWR) and pressurized heavy water reactors (PHWR), respectively, have been analyzed. Samples weighing in the range of a few tens of grams were irradiated in the thermal column of Apsara reactor to minimize neutron flux perturbations and high radiation dose. The method utilizes in situ relative detection efficiency using the γ-rays of selected activation products in the sample for overcoming γ-ray self-attenuation. Since the major and minor constituents (Zr, Sn, Fe, Cr and/or Ni) in these samples were amenable to NAA, the absolute concentrations of all the elements were determined using mass balance instead of using the concentration of the internal mono standard. Concentrations were also determined in a smaller size Zircaloy-4 sample by irradiating in the core position of the reactor to validate the present methodology. The results were compared with literature specifications and were found to be satisfactory. Values of sensitivities and detection limits have been evaluated for the elements analyzed.

  12. Psychometric Evaluation of the Summary of Diabetes Self-Care Activities-Arabic (SDSCA-Arabic): Translation and Analysis Process.

    PubMed

    AlJohani, Khalid A; Kendall, Garth E; Snider, Paul D

    2016-01-01

    To translate and examine the psychometric properties of the Arabic version of the Summary of Diabetes Self-Care Activities. An instrument translation and validation study. A total of 243 participants (33 first sample and 210 second sample) diagnosed with type 2 diabetes mellitus were recruited from four primary health care centers in Saudi Arabia. The study was guided by the World Health Organization guidelines for translation and validation of instrument. Translation indicators showed satisfactory outcomes for each included process in the forward-translation, an expert panel, and back-translation stages. Reliability and validity outcomes were as follows: test-retest, r = .912 and p < .001; split-half = .9; and Cronbach's alpha (α) = .76. The alpha scores for the subscales were as follows: diet, .89; exercise, .83; blood glucose testing, .92; and foot care, .77. Principal component analysis revealed the presence of four components with eigenvalues greater than 1.0, explaining 34.4, 16.4, 15.4, and 11.2% of the variance in everyday practices for these items, respectively (accumulated = 77.1%). The translation and validation processes revealed acceptable psychometric properties. The instrument could evaluate diabetes self-care in Saudi Arabia and has the potential to be used in other Arabic-speaking populations. © The Author(s) 2014.

  13. JOVE

    NASA Technical Reports Server (NTRS)

    Schiller, Stephen

    1997-01-01

    The focus of our JOVE research has been to develop a field instrument that provides high quality data for atmospheric corrections and in-flight calibration of airborne and satellite remote sensing imaging systems. The instrument package is known as the Portable Ground-based Atmospheric Monitoring System or PGAMS. PGAMS collects a comprehensive set of spectroscopic/radiometric observations that describe the optical properties of the atmosphere and reflectance of a target area on the earth's surface at the time of the aircraft or satellite overpass. To date, the PGAMS instrument system and control software has been completed and used for data collection in several NASA field experiments across the continental US and Puerto Rico. Where do you see your JOVE research going after the initial JOVE Funding Expires? Our JOVE initiated research will continue to be very active in supporting validation and calibration activities in remote sensing involving NASA, DOE, DOD, NSF, and possibly commercial supported programs. Future effort will focus on projects related to NASA's Mission to Planet Earth. This will include field work using PGAMS and data analysis that evaluates sensor calibration and atmospheric effects in images recorded by ASTER, MODIS, and MISR instruments aboard the AM-1 platform.

  14. Application of six sigma and AHP in analysis of variable lead time calibration process instrumentation

    NASA Astrophysics Data System (ADS)

    Rimantho, Dino; Rahman, Tomy Abdul; Cahyadi, Bambang; Tina Hernawati, S.

    2017-02-01

    Calibration of instrumentation equipment in the pharmaceutical industry is an important activity to determine the true value of a measurement. Preliminary studies indicated that occur lead-time calibration resulted in disruption of production and laboratory activities. This study aimed to analyze the causes of lead-time calibration. Several methods used in this study such as, Six Sigma in order to determine the capability process of the calibration instrumentation of equipment. Furthermore, the method of brainstorming, Pareto diagrams, and Fishbone diagrams were used to identify and analyze the problems. Then, the method of Hierarchy Analytical Process (AHP) was used to create a hierarchical structure and prioritize problems. The results showed that the value of DPMO around 40769.23 which was equivalent to the level of sigma in calibration equipment approximately 3,24σ. This indicated the need for improvements in the calibration process. Furthermore, the determination of problem-solving strategies Lead Time Calibration such as, shortens the schedule preventive maintenance, increase the number of instrument Calibrators, and train personnel. Test results on the consistency of the whole matrix of pairwise comparisons and consistency test showed the value of hierarchy the CR below 0.1.

  15. Analysis of RFI Statistics for Aquarius RFI Detection and Mitigation Improvements

    NASA Technical Reports Server (NTRS)

    de Matthaeis, Paolo; Soldo, Yan; Le Vine, David M.

    2016-01-01

    Aquarius is an L-band active/passive sensor designed to globally map sea surface salinity from space. Two instruments, a radar scatterometer and a radiometer, observe the same surface footprint almost simultaneously. The radiometer is the primary instrument for sensing sea surface salinity (SSS), while the scatterometer is included to provide a correction for sea surface roughness, which is a primary source of error in the salinity retrieval. Although the primary objective is the measurement of SSS, the instrument combination operates continuously, acquiring data over land and sea ice as well. An important feature of the data processing includes detection and mitigation of Radio Frequency Interference (RFI) which is done separately for both active and passive instruments. Correcting for RFI is particularly critical over ocean because of the high accuracy required in the brightness temperature measurements for SSS retrieval. It is also necessary for applications of the Aquarius data over land, where man-made interference is widespread, even though less accuracy is required in this case. This paper will provide an overview of the current status of the Aquarius RFI processing and an update on the ongoing work on the improvement of the RFI detection and mitigation performance.

  16. Study of dietary supplements compositions by neutron activation analysis at the VR-1 training reactor

    NASA Astrophysics Data System (ADS)

    Stefanik, Milan; Rataj, Jan; Huml, Ondrej; Sklenka, Lubomir

    2017-11-01

    The VR-1 training reactor operated by the Czech Technical University in Prague is utilized mainly for education of students and training of various reactor staff; however, R&D is also carried out at the reactor. The experimental instrumentation of the reactor can be used for the irradiation experiments and neutron activation analysis. In this paper, the neutron activation analysis (NAA) is used for a study of dietary supplements containing the zinc (one of the essential trace elements for the human body). This analysis includes the dietary supplement pills of different brands; each brand is represented by several different batches of pills. All pills were irradiated together with the standard activation etalons in the vertical channel of the VR-1 reactor at the nominal power (80 W). Activated samples were investigated by the nuclear gamma-ray spectrometry technique employing the semiconductor HPGe detector. From resulting saturated activities, the amount of mineral element (Zn) in the pills was determined using the comparative NAA method. The results show clearly that the VR-1 training reactor is utilizable for neutron activation analysis experiments.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keepin, G.R.

    Over the years the Los Alamos safeguards program has developed, tested, and implemented a broad range of passive and active nondestructive analysis (NDA) instruments (based on gamma and x-ray detection and neutron counting) that are now widely employed in safeguarding nuclear materials of all forms. Here very briefly, the major categories of gamma ray and neutron based NDA techniques, give some representative examples of NDA instruments currently in use, and cite a few notable instances of state-of-the-art NDA technique development. Historical aspects and a broad overview of the safeguards program are also presented.

  18. Family Engagement in Literacy Activities: Revised Factor Structure for the Familia--An Instrument Examining Family Support for Early Literacy Development

    ERIC Educational Resources Information Center

    Buhs, Eric S.; Welch, Greg; Burt, Jennifer; Knoche, Lisa

    2011-01-01

    This study evaluated a data-set drawn using "The Familia"--a measure originally developed to evaluate shared-reading activities. A newly developed set of conceptual supports and a confirmatory factor analysis (CFA) were applied to a new factor structure/model. Data were drawn from 219 young children and their families (mean age = 43…

  19. Mercury concentrations in museum specimens of tuna and swordfish

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, G.E.; Grant, P.M.; Kishore, R.

    1972-03-10

    The mercury levels of museum specimens of seven tuna caught 62 to 93 years ago and a swordfish caught 25 years ago have been determined by instrumental neutron activation analysis. These levels are in the same range as those found in specimens caught recently.

  20. Airborne Oceanographic Lidar (AOL) (Global Carbon Cycle)

    NASA Technical Reports Server (NTRS)

    2003-01-01

    This bimonthly contractor progress report covers the operation, maintenance and data management of the Airborne Oceanographic Lidar and the Airborne Topographic Mapper. Monthly activities included: mission planning, sensor operation and calibration, data processing, data analysis, network development and maintenance and instrument maintenance engineering and fabrication.

  1. Carbohydrate Structure Database: tools for statistical analysis of bacterial, plant and fungal glycomes

    PubMed Central

    Egorova, K.S.; Kondakova, A.N.; Toukach, Ph.V.

    2015-01-01

    Carbohydrates are biological blocks participating in diverse and crucial processes both at cellular and organism levels. They protect individual cells, establish intracellular interactions, take part in the immune reaction and participate in many other processes. Glycosylation is considered as one of the most important modifications of proteins and other biologically active molecules. Still, the data on the enzymatic machinery involved in the carbohydrate synthesis and processing are scattered, and the advance on its study is hindered by the vast bulk of accumulated genetic information not supported by any experimental evidences for functions of proteins that are encoded by these genes. In this article, we present novel instruments for statistical analysis of glycomes in taxa. These tools may be helpful for investigating carbohydrate-related enzymatic activities in various groups of organisms and for comparison of their carbohydrate content. The instruments are developed on the Carbohydrate Structure Database (CSDB) platform and are available freely on the CSDB web-site at http://csdb.glycoscience.ru. Database URL: http://csdb.glycoscience.ru PMID:26337239

  2. Design of Instrument Control Software for Solar Vector Magnetograph at Udaipur Solar Observatory

    NASA Astrophysics Data System (ADS)

    Gosain, Sanjay; Venkatakrishnan, P.; Venugopalan, K.

    2004-04-01

    A magnetograph is an instrument which makes measurement of solar magnetic field by measuring Zeeman induced polarization in solar spectral lines. In a typical filter based magnetograph there are three main modules namely, polarimeter, narrow-band spectrometer (filter), and imager(CCD camera). For a successful operation of magnetograph it is essential that these modules work in synchronization with each other. Here, we describe the design of instrument control system implemented for the Solar Vector Magnetograph under development at Udaipur Solar Observatory. The control software is written in Visual Basic and exploits the Component Object Model (COM) components for a fast and flexible application development. The user can interact with the instrument modules through a Graphical User Interface (GUI) and can program the sequence of magnetograph operations. The integration of Interactive Data Language (IDL) ActiveX components in the interface provides a powerful tool for online visualization, analysis and processing of images.

  3. Comparison of 3 measures of physical activity and associations with blood pressure, HDL, and body composition in a sample of adolescents.

    PubMed

    Hearst, Mary O; Sirard, John R; Lytle, Leslie; Dengel, Donald R; Berrigan, David

    2012-01-01

    The association of physical activity (PA), measured 3 ways, and biomarkers were compared in a sample of adolescents. PA data were collected on 2 cohorts of adolescents (N = 700) in the Twin Cities, Minnesota, 2007-2008. PA was measured using 2 survey questions [Modified Activity Questionnaire (MAQ)], the 3-Day Physical Activity Recall (3DPAR), and accelerometers. Biomarkers included systolic (SBP) and diastolic blood pressure (DBP), lipids, percent body fat (%BF), and body mass index (BMI) percentile. Bivariate relationships among PA measures and biomarkers were examined followed by generalized estimating equations for multivariate analysis. The 3 measures were significantly correlated with each other (r = .22-.36, P < .001). Controlling for study, puberty, age, and gender, all 3 PA measures were associated with %BF (MAQ = -1.93, P < .001; 3DPAR = -1.64, P < .001; accelerometer = -1.06, P = .001). The MAQ and accelerometers were negatively associated with BMI percentile. None of the 3 PA measures were significantly associated with SBP or lipids. The percentage of adolescents meeting the national PA recommendations varied by instrument. All 3 instruments demonstrated consistent findings when estimating associations with %BF, but were different for prevalence estimates. Researchers must carefully consider the intended use of PA data when choosing a measurement instrument.

  4. Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Lichte, F.E.; Meier, A.L.; Crock, J.G.

    1987-01-01

    A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.

  5. Simulation Studies of Satellite Laser CO2 Mission Concepts

    NASA Technical Reports Server (NTRS)

    Kawa, Stephan Randy; Mao, J.; Abshire, J. B.; Collatz, G. J.; Sun X.; Weaver, C. J.

    2011-01-01

    Results of mission simulation studies are presented for a laser-based atmospheric CO2 sounder. The simulations are based on real-time carbon cycle process modeling and data analysis. The mission concept corresponds to ASCENDS as recommended by the US National Academy of Sciences Decadal Survey. Compared to passive sensors, active (lidar) sensing of CO2 from space has several potentially significant advantages that hold promise to advance CO2 measurement capability in the next decade. Although the precision and accuracy requirements remain at unprecedented levels of stringency, analysis of possible instrument technology indicates that such sensors are more than feasible. Radiative transfer model calculations, an instrument model with representative errors, and a simple retrieval approach complete the cycle from "nature" run to "pseudodata" CO2. Several mission and instrument configuration options are examined, and the sensitivity to key design variables is shown. Examples are also shown of how the resulting pseudo-measurements might be used to address key carbon cycle science questions.

  6. Apps of Steel: Are Exercise Apps Providing Consumers with Realistic Expectations?: A Content Analysis of Exercise Apps for Presence of Behavior Change Theory

    ERIC Educational Resources Information Center

    Cowan, Logan T.; Van Wagenen, Sarah A.; Brown, Brittany A.; Hedin, Riley J.; Seino-Stephan, Yukiko; Hall, P. Cougar; West, Joshua H.

    2013-01-01

    Objective. To quantify the presence of health behavior theory constructs in iPhone apps targeting physical activity. Methods. This study used a content analysis of 127 apps from Apple's (App Store) "Health & Fitness" category. Coders downloaded the apps and then used an established theory-based instrument to rate each app's inclusion of…

  7. Analysis of an Air Conditioning Coolant Solution for Metal Contamination Using Atomic Absorption Spectroscopy: An Undergraduate Instrumental Analysis Exercise Simulating an Industrial Assignment

    ERIC Educational Resources Information Center

    Baird, Michael J.

    2004-01-01

    A real-life analytical assignment is presented to students, who had to examine an air conditioning coolant solution for metal contamination using an atomic absorption spectroscopy (AAS). This hands-on access to a real problem exposed the undergraduate students to the mechanism of AAS, and promoted participation in a simulated industrial activity.

  8. NAA For Human Serum Analysis: Comparison With Conventional Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oliveira, Laura C.; Zamboni, Cibele B.; Medeiros, Jose A. G.

    2010-08-04

    Instrumental and Comparator methods of Neutron Activation Analysis (NAA) were applied to determine elements of clinical relevancy in serum samples of adult population (Sao Paulo city, Brazil). A comparison with the conventional analyses, Colorimetric for calcium, Titrymetric for chlorine and Ion Specific Electrode for sodium and potassium determination were also performed permitting a discussion about the performance of NAA methods for clinical chemistry research.

  9. Compositions of Three Lunar Meteorites: Meteorite Hills 01210, Northeast Africa 001, and Northwest Africa 3136

    NASA Technical Reports Server (NTRS)

    Korotev, R. L.; Irving, A. J.

    2005-01-01

    We report on compositions obtained by instrumental neutron activation analysis on three new lunar meteorites, MET 01210 (Meteorite Hills, Antarctica; 23 g), NEA 001 (Northeast Africa, Sudan; 262 g), and NWA 3136 (Northwest Africa, Algeria or Morocco; 95 g). As in previous similar studies, we divided our samples into many (8-9) small (approximately 30 mg) subsamples prior to analysis.

  10. Research in Observations of Oceanic Air/Sea Interaction

    NASA Technical Reports Server (NTRS)

    Long, David G.; Arnold, David V.

    1995-01-01

    The primary purpose of this research has been: (1) to develop an innovative research radar scatterometer system capable of directly measuring both the radar backscatter and the small-scale and large-scale ocean wave field simultaneously and (2) deploy this instrument to collect data to support studies of air/sea interaction. The instrument has been successfully completed and deployed. The system deployment lasted for six months during 1995. Results to date suggest that the data is remarkably useful in air/sea interaction studies. While the data analysis is continuing, two journal and fifteen conference papers have been published. Six papers are currently in review with two additional journal papers scheduled for publication. Three Master's theses on this research have been completed. A Ph.D. student is currently finalizing his dissertation which should be completed by the end of the calendar year. We have received additional 'mainstream' funding from the NASA oceans branch to continue data analysis and instrument operations. We are actively pursuing results from the data expect additional publications to follow. This final report briefly describes the instrument system we developed and results to-date from the deployment. Additional detail is contained in the attached papers selected from the bibliography.

  11. Supercritical fluid chromatography for GMP analysis in support of pharmaceutical development and manufacturing activities.

    PubMed

    Hicks, Michael B; Regalado, Erik L; Tan, Feng; Gong, Xiaoyi; Welch, Christopher J

    2016-01-05

    Supercritical fluid chromatography (SFC) has long been a preferred method for enantiopurity analysis in support of pharmaceutical discovery and development, but implementation of the technique in regulated GMP laboratories has been somewhat slow, owing to limitations in instrument sensitivity, reproducibility, accuracy and robustness. In recent years, commercialization of next generation analytical SFC instrumentation has addressed previous shortcomings, making the technique better suited for GMP analysis. In this study we investigate the use of modern SFC for enantiopurity analysis of several pharmaceutical intermediates and compare the results with the conventional HPLC approaches historically used for analysis in a GMP setting. The findings clearly illustrate that modern SFC now exhibits improved precision, reproducibility, accuracy and robustness; also providing superior resolution and peak capacity compared to HPLC. Based on these findings, the use of modern chiral SFC is recommended for GMP studies of stereochemistry in pharmaceutical development and manufacturing. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. The International Space Weather Initiative

    NASA Technical Reports Server (NTRS)

    Nat, Gopalswamy; Joseph, Davila; Barbara, Thompson

    2010-01-01

    The International Space Weather Initiative (ISWI) is a program of international cooperation aimed at understanding the external drivers of space weather. The ISWI program has its roots in the successful International Heliophysical Year (IHY) program that ran during 2007 - 2009 and will continue with those aspects that directly affect life on Earth. The primary objective of the ISWI program is to advance the space weather science by a combination of instrument deployment, analysis and interpretation of space weather data from the deployed instruments in conjunction with space data, and communicate the results to the public and students. Like the IHY, the ISWI will be a grass roots organization with key participation from national coordinators in cooperation with an international steering committee. This presentation outlines the ISWI program including its organizational aspects and proposed activities. The ISWI observatory deployment and outreach activities are highly complementary to the CAWSES II activities of SCOSTEP.

  13. Biological instrumentation for the Viking 1975 mission to Mars.

    PubMed

    Klein, H P; Vishniac, W

    1972-01-01

    A brief introduction is given on why Mars is of interest from a biological point of view, along with an overview of the Viking 1975 mission. Details are given about the four biology instruments aboard the spacecraft and the experiments for which they are to be used. These are: the carbon assimilation experiment to determine whether the soil is biologically active, by incubation in presence of 14C-labelled CO and CO2 (known to be present in the Martian atmosphere); the label release experiment to detect metabolic activity by the release of radioactive CO2, from 14C-labelled simple organic substrates; the gas exchange experiment to detect biological activity by repeated gas chromatography analysis of soil samples; the light scattering experiment, where increase of scattering and decrease of light transmission would indicate the growth of organisms. Examples are given of data obtained with terrestrial soils in these experiments.

  14. Predictors of quality of life and depression in older people living in temporary houses 13 months after the Wenchuan earthquake in western China: A cross-sectional study.

    PubMed

    Xie, Xia; Chen, Yanling; Chen, Hong; Au, Alma; Guo, Hongxia

    2017-06-01

    In this study, we explored the predictors of quality of life and depressive features in older people living in temporary housing 13 months after the Wenchuan earthquake in western China. Anonymous data were collected via questionnaires in a cross-sectional survey of 189 older people living in temporary housing 13 months after the earthquake. To explore the predictors of the outcomes of interest, Pearson correlation and multiple linear regression analysis were used. The results indicated that interests/hobbies, subjective support, and family function were positive predictors of quality of life, whereas instrumental activities of daily living and depressive symptoms were its negative predictors. In addition, we found that a higher level of instrumental activities of daily living predicted a greater likelihood of depression. These results suggested that developing strategies to decrease the instrumental activities of daily living score of these people helps improve their quality of life and depression. To enhance the quality of life of these individuals, healthcare providers should also focus on developing their interests/hobbies and provide them with adequate social support, especially subjective support. © 2017 John Wiley & Sons Australia, Ltd.

  15. Solar Dynamics Observatory Launch and Commissioning

    NASA Technical Reports Server (NTRS)

    O'Donnell, James R., Jr.; Kristin, D.; Bourkland, L.; Hsu, Oscar C.; Liu, Kuo-Chia; Mason, Paul A. C.; Morgenstern, Wendy M.; Russo, Angela M.; Starin, Scott R.; Vess, Melissa F.

    2011-01-01

    The Solar Dynamics Observatory (SDO) was launched on February 11, 2010. Over the next three months, the spacecraft was raised from its launch orbit into its final geosynchronous orbit and its systems and instruments were tested and calibrated in preparation for its desired ten year science mission studying the Sun. A great deal of activity during this time involved the spacecraft attitude control system (ACS); testing control modes, calibrating sensors and actuators, and using the ACS to help commission the spacecraft instruments and to control the propulsion system as the spacecraft was maneuvered into its final orbit. This paper will discuss the chronology of the SDO launch and commissioning, showing the ACS analysis work performed to diagnose propellant slosh transient and attitude oscillation anomalies that were seen during commissioning, and to determine how to overcome them. The simulations and tests devised to demonstrate correct operation of all onboard ACS modes and the activities in support of instrument calibration will be discussed and the final maneuver plan performed to bring SDO on station will be shown. In addition to detailing these commissioning and anomaly resolution activities, the unique set of tests performed to characterize SDO's on-orbit jitter performance will be discussed.

  16. Active coherent laser spectrometer for remote detection and identification of chemicals

    NASA Astrophysics Data System (ADS)

    MacLeod, Neil A.; Weidmann, Damien

    2012-10-01

    Currently, there exists a capability gap for the remote detection and identification of threat chemicals. We report here on the development of an Active Coherent Laser Spectrometer (ACLaS) operating in the thermal infrared and capable of multi-species stand-off detection of chemicals at sub ppm.m levels. A bench top prototype of the instrument has been developed using distributed feedback mid-infrared quantum cascade lasers as spectroscopic sources. The instrument provides active eye-safe illumination of a topographic target and subsequent spectroscopic analysis through optical heterodyne detection of the diffuse backscattered field. Chemical selectivity is provided by the combination of the narrow laser spectral bandwidth (typically < 2 MHz) and frequency tunability that allows the recording of the full absorption spectrum of any species within the instrument line of sight. Stand-off detection at distances up to 12 m has been demonstrated on light molecules such as H2O, CH4 and N2O. A physical model of the stand-off detection scenario including ro-vibrational molecular absorption parameters was used in conjunction with a fitting algorithm to retrieve quantitative mixing ratio information on multiple absorbers.

  17. Effect of a multimodal exercise program on sleep disturbances and instrumental activities of daily living performance on Parkinson's and Alzheimer's disease patients.

    PubMed

    Nascimento, Carla Manuela Crispim; Ayan, Carlos; Cancela, Jose Maria; Gobbi, Lilian Teresa Bucken; Gobbi, Sebastião; Stella, Florindo

    2014-04-01

    To assess the contribution of a multimodal exercise program on the sleep disturbances (SD) and on the performance of instrumental activities daily living (IADL) in patients with clinical diagnosis of Alzheimer's disease (AD) and Parkinson's disease patients (PD). A total of 42 consecutive patients (23 training group, 19 control group) with PD and 35 demented patients with AD (19 trained group, 16 control group) were recruited. Participants in both training groups carried out three 1-h sessions per week of a multimodal exercise program for 6 months. The Pfeffer Questionnaire for Instrumental Activities and the Mini-Sleep Questionnaire were used to assess the effects of the program on IADL and SD respectively. Two-way ancova showed interactions in IADL and SD. Significant improvements were observed for these variables in both intervention groups, and maintenance or worsening was observed in control groups. The analysis of effect size showed these improvements. The present study results show that a mild to moderate intensity of multimodal physical exercises carried out on a regular basis over 6 months can contribute to reducing IADL deficits and attenuating SD. © 2013 Japan Geriatrics Society.

  18. Analytical Chemistry Laboratory Progress Report for FY 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, D.W.; Boparai, A.S.; Bowers, D.L.

    The purpose of this report is to summarize the activities of the Analytical Chemistry Laboratory (ACL) at Argonne National Laboratory (ANL) for Fiscal Year (FY) 1994 (October 1993 through September 1994). This annual report is the eleventh for the ACL and describes continuing effort on projects, work on new projects, and contributions of the ACL staff to various programs at ANL. The Analytical Chemistry Laboratory is a full-cost-recovery service center, with the primary mission of providing a broad range of analytical chemistry support services to the scientific and engineering programs at ANL. The ACL also has a research program inmore » analytical chemistry, conducts instrumental and methods development, and provides analytical services for governmental, educational, and industrial organizations. The ACL handles a wide range of analytical problems. Some routine or standard analyses are done, but it is common for the Argonne programs to generate unique problems that require significant development of methods and adaption of techniques to obtain useful analytical data. The ACL has four technical groups -- Chemical Analysis, Instrumental Analysis, Organic Analysis, and Environmental Analysis -- which together include about 45 technical staff members. Talents and interests of staff members cross the group lines, as do many projects within the ACL. The Chemical Analysis Group uses wet- chemical and instrumental methods for elemental, compositional, and isotopic determinations in solid, liquid, and gaseous samples and provides specialized analytical services. Major instruments in this group include an ion chromatograph (IC), an inductively coupled plasma/atomic emission spectrometer (ICP/AES), spectrophotometers, mass spectrometers (including gas-analysis and thermal-ionization mass spectrometers), emission spectrographs, autotitrators, sulfur and carbon determinators, and a kinetic phosphorescence uranium analyzer.« less

  19. Reduction of interferences in the analysis of Children's Dimetapp using ultraviolet spectroscopy data and target factor analysis

    NASA Astrophysics Data System (ADS)

    Msimanga, Huggins Z.; Lam, Truong Thach Ho; Latinwo, Nathaniel; Song, Mihyang Kristy; Tavakoli, Newsha

    2018-03-01

    A calibration matrix has been developed and successfully applied to quantify actives in Children's Dimetapp®, a cough mixture whose active components suffer from heavy spectral interference. High-performance liquid chromatography/photodiode array instrument was used to identify the actives and any other UV-detectable excipients that might contribute to interferences. The instrument was also used to obtain reference data on the actives, instead of relying on the manufacturer's claims. Principal component analysis was used during the developmental stages of the calibration matrix to highlight any mismatch between the calibration and sample spectra, making certain that "apples" were not compared with "oranges". The prediction model was finally calculated using target factor analysis and partial least squares regression. In addition to the actives in Children's Dimetapp® (brompheniramine maleate, phenylephrine hydrogen chloride, and dextromethorphan hydrogen bromide), sodium benzoate was identified as the major and FD&C Blue #1, FD&C Red #40, and methyl anthranilate as minor spectral interferences. Model predictions were compared before and after the interferences were included into the calibration matrix. Before including interferences, the following results were obtained: brompheniramine maleate = 481.3 mg L- 1 ± 134% RE; phenylephrine hydrogen chloride = 1041 mg L- 1 ± 107% RE; dextromethorphan hydrogen bromide = 1571 mg L- 1 ± 107% RE, where % RE = percent relative error based on the reference HPLC data. After including interferences, the results were as follows: brompheniramine maleate = 196.3 mg L- 1 ± 4.4% RE; phenylephrine hydrogen chloride = 501.3 mg L- 1 ± 0.10% RE; dextromethorphan hydrogen bromide = 998.7 mg L- 1 ± 1.6% RE as detailed in Table 6.

  20. Baseline dental plaque activity, mutans streptococci culture, and future caries experience in children.

    PubMed

    Hallett, Kerrod B; O'Rourke, Peter K

    2013-01-01

    The purpose of this study was to evaluate a chairside caries risk assessment protocol utilizing a caries prediction instrument, adenosine triphosphate (ATP) activity in dental plaque, mutans streptococci (MS) culture, and routine dental examination in five- to 10-year-old children at two regional Australian schools with high caries experience. Clinical indicators for future caries were assessed at baseline examination using a standardized prediction instrument. Plaque ATP activity was measured directly in relative light units (RLU) using a bioluminescence meter, and MS culture data were recorded. Each child's dentition was examined clinically and radiographically, and caries experience was recorded using enamel white spot lesions and decayed, missing, and filled surfaces for primary and permanent teeth indices. Univariate one-way analysis of variance between selected clinical indicators, ATP activity, MS count at baseline, and future new caries activity was performed, and a generalized linear model for prediction of new caries activity at 24 months was constructed. Future new caries activity was significantly associated with the presence of visible cavitations, reduced saliva flow, and orthodontic appliances at baseline (R(2)=0.2, P<.001). Baseline plaque adenosine triphosphate activity and mutans streptococci counts were not significantly associated with caries activity at 24 months.

  1. Stress Be Not Proud: The Myth of Burnout.

    ERIC Educational Resources Information Center

    DeMoulin, Donald F.

    1991-01-01

    Analysis of data from 827 professional educators, using the Career Awareness Index and the Instrument Summary Assessment Program, indicates that "burnout" may be an inappropriate descriptor of low to moderate levels of self-efficacy and personal productivity. Professional development activities should be specifically designed to match individual…

  2. Experiential Education: Enhancing the Liberal Arts Curriculum

    ERIC Educational Resources Information Center

    Graff, Elissa R.

    2013-01-01

    This mixed-methods study combined a survey instrument, the Learning Style Inventory (LSI), with a selected group of follow-up interviews for the purpose of determining how experiential practices affected student engagement and learning. Quantitative data analysis established students' preferences for more active involvement in learning practices…

  3. Elemental analysis of granite by instrumental neutron activation analysis (INAA) and X-ray fluorescence analysis (XRF).

    PubMed

    El-Taher, A

    2012-01-01

    The instrumental neutron activation analysis technique (INAA) was used for qualitative and quantitative analysis of granite samples collected from four locations in the Aswan area in South Egypt. The samples were prepared together with their standards and simultaneously irradiated in a neutron flux of 7×10(11)n/cm(2)s in the TRIGA Mainz research reactor. Gamma-ray spectra from an hyper-pure germanium detector were analyzed. The present study provides the basic data of elemental concentrations of granite rocks. The following elements have been determined Na, Mg, K, Fe, Mn, Sc, Cr, Ti, Co, Zn, Ga, Rb, Zr, Nb, Sn, Ba, Cs, La, Ce, Nd, Sm, Eu, Yb, Lu, Hf, Ta, Th and U. The X-ray fluorescence (XRF) was used for comparison and to detect elements, which can be detected only by XRF such as F, S, Cl, Co, Cu, Mo, Ni, Pb, Se and V. The data presented here are our contribution to understanding the elemental composition of the granite rocks. Because there are no existing databases for the elemental analysis of granite, our results are a start to establishing a database for the Egyptian granite. It is hoped that the data presented here will be useful to those dealing with geochemistry, granite chemistry and related fields. Copyright © 2011 Elsevier Ltd. All rights reserved.

  4. On the signatures of flare-induced global waves in the Sun: GOLF and VIRGO observations

    NASA Astrophysics Data System (ADS)

    Kumar, Brajesh; Mathur, Savita; García, Rafael A.; Jiménez, Antonio

    2017-11-01

    Recently, several efforts have been made to identify the seismic signatures of flares and magnetic activity in the Sun and Sun-like stars. In this work, we have analysed the disc-integrated velocity and intensity observations of the Sun obtained from the Global Oscillations at Low Frequencies (GOLF) and Variability of solar IRradiance and Gravity Oscillations/Sun photometers (VIRGO/SPM) instruments, respectively, on board the Solar and Heliospheric Observatory space mission covering several successive flare events, for the period from 2011 February 11 to 2011 February 17, of which 2011 February 11 remained a relatively quiet day and served as a `null test' for the investigation. Application of the spectral analysis to these disc-integrated Sun-as-a-star velocity and intensity signals indicates that there is enhanced power of the global modes of oscillations in the Sun during the flares, as compared to the quiet day. The GOLF instrument obtains velocity observations using the Na I D lines which are formed in the upper solar photosphere, while the intensity data used in our analysis are obtained by VIRGO/SPM instrument at 862 nm, which is formed within the solar photosphere. Despite the fact that the two instruments sample different layers of the solar atmosphere using two different parameters (velocity versus intensity), we have found that both these observations show the signatures of flare-induced global waves in the Sun. These results could suffice in identifying the asteroseismic signatures of stellar flares and magnetic activity in the Sun-like stars.

  5. Development and Psychometric Evaluation of the Instrument: Attitudes Towards Organ Donor Advocacy Scale (ATODAS)

    PubMed Central

    Flodén, Anne; Lennerling, Annette; Fridh, Isabell; Rizell, Magnus; Forsberg, Anna

    2011-01-01

    The consequences of advocacy in nursing are critical when caring for a potential organ donor. No specific instrument has been available to measure attitudes toward organ donor advocacy. The aim of this study was to develop and psychometrically evaluate an instrument for measuring intensive and critical care (ICU) nurses’ attitudes toward organ donor advocacy. The study was conducted in two stages: instrument development and instrument evaluation and refinement. A questionnaire was developed (Attitude Toward Organ Donor Advocacy Scale (ATODAS)), which was sent to half of all nurses working in ICUs (general-, neuro-, thoracic- or paediatric-) in Sweden (n=1180). The final response rate was 42.5% (n=502). In order to explore validity and reliability, the expected scale dimensionality of the questionnaire was examined both by explorative principal component analysis (with oblique, varimax rotation) and by confirmatory multi-trait analysis. The confirmatory factor analysis indicated that the ATODAS could best be explained by five factors; Attitudes toward championing organ donation at a structural hospital level; Attitudes toward championing organ donation at a political and research level; Attitudes toward actively and personally safeguarding the will and wishes of the potential organ donor, Attitudes toward safeguarding the potential donor’s will and wishes by a professional approach and Attitudes toward safeguarding the will and wishes of the relatives. This initial testing indicated that the ATODAS has good psychometric properties and can be used in future research to explore if interventions may influence attitudes and behaviors related to organ donor advocacy. PMID:22046210

  6. Cloud and aerosol studies using combined CPL and MAS data

    NASA Astrophysics Data System (ADS)

    Vaughan, Mark A.; Rodier, Sharon; Hu, Yongxiang; McGill, Matthew J.; Holz, Robert E.

    2004-11-01

    Current uncertainties in the role of aerosols and clouds in the Earth's climate system limit our abilities to model the climate system and predict climate change. These limitations are due primarily to difficulties of adequately measuring aerosols and clouds on a global scale. The A-train satellites (Aqua, CALIPSO, CloudSat, PARASOL, and Aura) will provide an unprecedented opportunity to address these uncertainties. The various active and passive sensors of the A-train will use a variety of measurement techniques to provide comprehensive observations of the multi-dimensional properties of clouds and aerosols. However, to fully achieve the potential of this ensemble requires a robust data analysis framework to optimally and efficiently map these individual measurements into a comprehensive set of cloud and aerosol physical properties. In this work we introduce the Multi-Instrument Data Analysis and Synthesis (MIDAS) project, whose goal is to develop a suite of physically sound and computationally efficient algorithms that will combine active and passive remote sensing data in order to produce improved assessments of aerosol and cloud radiative and microphysical properties. These algorithms include (a) the development of an intelligent feature detection algorithm that combines inputs from both active and passive sensors, and (b) identifying recognizable multi-instrument signatures related to aerosol and cloud type derived from clusters of image pixels and the associated vertical profile information. Classification of these signatures will lead to the automated identification of aerosol and cloud types. Testing of these new algorithms is done using currently existing and readily available active and passive measurements from the Cloud Physics Lidar and the MODIS Airborne Simulator, which simulate, respectively, the CALIPSO and MODIS A-train instruments.

  7. Psychometric properties of the Greek version of Jacelon Attributed Dignity Scale.

    PubMed

    Papastavrou, Evridiki; Charitou, Paraskevi; Kouta, Christiana

    2017-08-01

    Maintaining dignity is important for successful aging, but there is lack of validated research instruments in the nursing literature to investigate dignity as perceived by the old people. This is a methodological study aiming to investigate the psychometric properties of the Greek version of Jacelon Attributed Dignity Scale as translated in the Greek language. A methodological approach consisting of translation, adaptation, and cross-cultural validation. A sample of 188 Greek-speaking old Cypriot persons drawn from the Hospital outpatient departments was asked to complete the Greek versions of Jacelon Attributed Dignity Scale and the Instrumental Activities of Daily Living. Data analyses included internal consistency reliability (Cronbach's alpha coefficient), item analysis, and exploratory factor analysis using principal component method with orthogonal varimax rotation. Ethical considerations: The study protocol was approved by the National Bioethics committee according to the national legislation. Permission to use the research instrument was granted from the author. Information about the aim and the benefits of the study was included in the information letter. Cronbach's alpha for Greek version of Jacelon Attributed Dignity Scale was 0.90. Four factors emerged explaining 65.28% of the total variance, and item to total correlation values ranged from 0.25 to 0.74 indicating high internal consistency and homogeneity. Mean item score in Instrumental Activities of Daily Living was 5.6 (standard deviation = 1.7) for men and 6.7 (standard deviation = 1.7) for women, and the correlations between demographics, Instrumental Activities of Daily Living, and the four factors of the Greek version of Jacelon Attributed Dignity Scale were low; also in multiple linear regression, the values of R 2 are presented low. Demographic characteristics and degree of functionality seem to be associated with some of the dimensions of dignity but with low correlations; therefore, they cannot predict attributed dignity. The Greek version of Jacelon Attributed Dignity Scale is a valid and reliable tool to measure attributed dignity in Greek-speaking older adults, but further testing of the psychometric properties and other potential factors that may affect the attributed dignity is needed.

  8. Alkylphenols, polycyclic aromatic hydrocarbons, and organochlorines in sediment from Lake Shihwa, Korea: Instrumental and bioanalytical characterization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khim, J.S.; Villeneuve, D.L.; Kannan, K.

    1999-11-01

    Lake Shihwa is an artificial lake, located on the west coast of Korea, that has experienced environmental deterioration since 1994, when it was formed by construction of a sea dike. This study used instrumental analysis and in vitro bioassays to characterize organic contaminants in sediment collected from 11 stations on Lake Shihwa. Alkylphenol (AP) concentrations in Lake Shihwa sediment ranged from 20.2 to 1,820 ng/g nonylphenol and from 4.69 to 50.5 ng/g octylphenol, on a dry weight basis. Maximum concentrations of polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides, and polychlorinated biphenyls (PCBs) were 30.8, 2.26, and 12.3 ng/g (dry weight), respectively.more » Significant estrogenic activity was associated with fractions containing APs. Mass-balance analysis suggested that reported concentrations of APs account for less than 20% of the estrogenic activity observed. No significant dioxin like activity was associated with fractions containing classic aryl hydrocarbon receptor agonists, such as PCBs, but the mid-polarity fractions containing PAHs and most polar fractions yielded significant dioxin like activity. Overall, most of the in vitro bioassay responses appear to have been caused by unidentified and/or undetectable compounds associated with Lake Shihwa sediment.« less

  9. High Energy Astrophysics Program

    NASA Technical Reports Server (NTRS)

    1996-01-01

    This report reviews activities performed-by members of the USRA contract team during the six months of the reporting period and projected activities during the coming six months. Activities take place at the Goddard Space Flight Center, visiting the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in Astrophysics. Missions supported include: Advanced Satellite for Cosmology and Astrophysics (ASCA); X-ray Timing Experiment (XTE); X-ray Spectrometer (XRS); Astro-E; High Energy Astrophysics Science Archive Research Center (HEASARC), and others.

  10. High Energy Astrophysics Research and Programmatic Support

    NASA Technical Reports Server (NTRS)

    Angelini, Lorella

    1998-01-01

    This report reviews activities performed by members of the USRA contract team during the six months of the reporting period and projected activities during the coming six months. Activities take place at the Goddard Space Flight Center, within the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in Astrophysics. Missions supported include: Advanced Satellite for Cosmology and Astrophysics (ASCA), X-ray Timing Experiment (XTE), X-ray Spectrometer (XRS), Astro-E, High Energy Astrophysics Science Archive Research Center (HEASARC), and others.

  11. High Energy Astrophysics Program (HEAP)

    NASA Technical Reports Server (NTRS)

    Angelini, Lorella; Corcoran, Michael; Drake, Stephen; McGlynn, Thomas A.; Snowden, Stephen; Mukai, Koji; Cannizzo, John; Lochner, James; Rots, Arnold; Christian, Eric; hide

    1998-01-01

    This report reviews activities performed by the members of the USRA contract team during the 6 months of the reporting period and projected activities during the coming 6 months. Activities take place at the Goddard Space Flight Center, within the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in astrophysics. Supported missions include advanced Satellite for Cosmology and Astrophysics (ASCA), X-Ray Timing Experiment (XTE), X-Ray Spectrometer (XRS), Astro-E, High Energy Astrophysics Science Archive Research Center (HEASARC) and others.

  12. High Energy Astrophysics Program (HEAP)

    NASA Technical Reports Server (NTRS)

    Angelini, L.

    1998-01-01

    This report reviews activities performed by members of the USRA contract team during the six months of the reporting period and projected activities during the coming six months. Activities take place at the Goddard Space Flight Center, within the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in Astrophysics Missions supported include: Advanced Satellite for Cosmology and Astrophysics (ASCA), X-ray Timing Experiment (XTE), X-ray Spectrometer (XRS), Astro-E, High Energy Astrophysics Science Archive Research Center (HEASARC), and others.

  13. High Energy Astrophysics Research and Programmatic Support

    NASA Technical Reports Server (NTRS)

    Angelini, L. (Editor)

    1997-01-01

    This report reviews activities performed by members of the USRA contract team during the six months of the reporting period and projected activities during the coming six months. Activities take place at the Goddard Space Flight Center, within the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in Astrophysics. Missions supported include: Advanced Satellite for Cosmology and Astrophysics (ASCA), X-ray Timing Experiment (XTE), X-ray Spectrometer (XRS), Astro-E, High Energy Astrophysics Science Archive Research Center (HEASARC), and others.

  14. Developing a workplace resilience instrument.

    PubMed

    Mallak, Larry A; Yildiz, Mustafa

    2016-05-27

    Resilience benefits from the use of protective factors, as opposed to risk factors, which are associated with vulnerability. Considerable research and instrument development has been conducted in clinical settings for patients. The need existed for an instrument to be developed in a workplace setting to measure resilience of employees. This study developed and tested a resilience instrument for employees in the workplace. The research instrument was distributed to executives and nurses working in the United States in hospital settings. Five-hundred-forty completed and usable responses were obtained. The instrument contained an inventory of workplace resilience, a job stress questionnaire, and relevant demographics. The resilience items were written based on previous work by the lead author and inspired by Weick's [1] sense-making theory. A four-factor model yielded an instrument having psychometric properties showing good model fit. Twenty items were retained for the resulting Workplace Resilience Instrument (WRI). Parallel analysis was conducted with successive iterations of exploratory and confirmatory factor analyses. Respondents were classified based on their employment with either a rural or an urban hospital. Executives had significantly higher WRI scores than nurses, controlling for gender. WRI scores were positively and significantly correlated with years of experience and the Brief Job Stress Questionnaire. An instrument to measure individual resilience in the workplace (WRI) was developed. The WRI's four factors identify dimensions of workplace resilience for use in subsequent investigations: Active Problem-Solving, Team Efficacy, Confident Sense-Making, and Bricolage.

  15. Requirements and Design Reference Mission for the WFIRST-AFTA Coronagraph Instrument

    NASA Technical Reports Server (NTRS)

    Demers, Richard T.; Dekens, Frank; Calvet, Rob; Chang, Zensheu; Effinger, Robert; Ek, Eric; Hovland, Larry; Jones, Laura; Loc, Anthony; Nemati, Bijan; hide

    2015-01-01

    The WFIRST-AFTA coronagraph instrument take s advantage of AFTA s 2.4 -meter aperture to provide novel exoplanet imaging science at approximately the same instrument cost as an Explorer mission. The AFTA coronagraph also matures direct imaging technologies to high TRL for an Exo-Earth Imager in the next decade. The coronagraph Design Reference Mission (DRM) optical design is based on the highly successful High Contrast Imaging Testbed (HCIT), with modifications to accommodate the AFTA telescope design, service-ability, volume constraints, and the addition of an Integral Field Spectrograph (IFS). In order to optimally satisfy the three science objectives of planet imaging, planet spectral characterization and dust debris imaging, the coronagraph is designed to operate in two different modes : Hybrid Lyot Coronagraph or Shaped Pupil Coronagraph. Active mechanisms change pupil masks, focal plane masks, yot masks, and bandpass filters to shift between modes. A single optical beam train can thus operate alternatively as two different coronagraph architecture s. Structural Thermal Optical Performance (STOP) analysis predict s the instrument contrast with the Low Order Wave Front Control loop closed. The STOP analysis was also used to verify that the optical/structural/thermal design provides the extreme stability required for planet characterization in the presence of thermal disturbances expected in a typical observing scenario. This paper describes the instrument design and the flow down from science requirements to high level engineering requirements.

  16. The brain in time: insights from neuromagnetic recordings.

    PubMed

    Hari, Riitta; Parkkonen, Lauri; Nangini, Cathy

    2010-03-01

    The millisecond time resolution of magnetoencephalography (MEG) is instrumental for investigating the brain basis of sensory processing, motor planning, cognition, and social interaction. We review the basic principles, recent progress, and future potential of MEG in noninvasive tracking of human brain activity. Cortical activation sequences from tens to hundreds of milliseconds can be followed during, e.g., perception, motor action, imitation, and language processing by recording both spontaneous and evoked brain signals. Moreover, tagging of sensory input can be used to reveal neuronal mechanisms of binaural interaction and perception of ambiguous images. The results support the emerging ideas of multiple, hierarchically organized temporal scales in human brain function. Instrumentation and data analysis methods are rapidly progressing, enabling attempts to decode the four-dimensional spatiotemporal signal patterns to reveal correlates of behavior and mental contents.

  17. Imaging flow cytometry for phytoplankton analysis.

    PubMed

    Dashkova, Veronika; Malashenkov, Dmitry; Poulton, Nicole; Vorobjev, Ivan; Barteneva, Natasha S

    2017-01-01

    This review highlights the concepts and instrumentation of imaging flow cytometry technology and in particular its use for phytoplankton analysis. Imaging flow cytometry, a hybrid technology combining speed and statistical capabilities of flow cytometry with imaging features of microscopy, is rapidly advancing as a cell imaging platform that overcomes many of the limitations of current techniques and contributed significantly to the advancement of phytoplankton analysis in recent years. This review presents the various instrumentation relevant to the field and currently used for assessment of complex phytoplankton communities' composition and abundance, size structure determination, biovolume estimation, detection of harmful algal bloom species, evaluation of viability and metabolic activity and other applications. Also we present our data on viability and metabolic assessment of Aphanizomenon sp. cyanobacteria using Imagestream X Mark II imaging cytometer. Herein, we highlight the immense potential of imaging flow cytometry for microalgal research, but also discuss limitations and future developments. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Ocean Optics Protocols for Satellite Ocean Color Sensor Validation. Volume 6; Special Topics in Ocean Optics Protocols and Appendices; Revised

    NASA Technical Reports Server (NTRS)

    Mueller, J. L. (Editor); Fargion, Giulietta S. (Editor); McClain, Charles R. (Editor)

    2003-01-01

    This document stipulates protocols for measuring bio-optical and radiometric data for the Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) Project activities and algorithm development. The document is organized into 6 separate volumes as Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 4. Volume I: Introduction, Background and Conventions; Volume II: Instrument Specifications, Characterization and Calibration; Volume III: Radiometric Measurements and Data Analysis Methods; Volume IV: Inherent Optical Properties: Instruments, Characterization, Field Measurements and Data Analysis Protocols; Volume V: Biogeochemical and Bio-Optical Measurements and Data Analysis Methods; Volume VI: Special Topics in Ocean Optics Protocols and Appendices. The earlier version of Ocean Optics Protocols for Satellite Ocean Color Sensor Validation, Revision 3 (Mueller and Fargion 2002, Volumes 1 and 2) is entirely superseded by the six volumes of Revision 4 listed above.

  19. Hubble Space Telescope servicing mission scientific instrument protective enclosure design requirements and contamination controls

    NASA Technical Reports Server (NTRS)

    Hansen, Patricia A.; Hughes, David W.; Hedgeland, Randy J.; Chivatero, Craig J.; Studer, Robert J.; Kostos, Peter J.

    1994-01-01

    The Scientific Instrument Protective Enclosures were designed for the Hubble Space Telescope Servicing Missions to provide a beginning environment to a Scientific Instrument during ground and on orbit activities. The Scientific Instruments required very stringent surface cleanliness and molecular outgassing levels to maintain ultraviolet performance. Data from the First Servicing Mission verified that both the Scientific Instruments and Scientific Instrument Protective Enclosures met surface cleanliness level requirements during ground and on-orbit activities.

  20. Index of Refraction without Geometry

    ERIC Educational Resources Information Center

    Farkas, N.; Henriksen, P. N.; Ramsier, R. D.

    2006-01-01

    This article presents several activities that permit students to determine the index of refraction of transparent solids and liquids using simple equipment without the need for geometrical relationships, special lighting or optical instruments. Graphical analysis of the measured data is shown to be a useful method for determining the index of…

  1. 78 FR 33837 - Agency Information Collection Activities; Submission to the Office of Management and Budget for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-05

    ... specific information/performance data for analysis of the experiments. This effort will assist the... Sites Data Collection Instrument AGENCY: Federal Student Aid (FSA), Department of Education (ED). ACTION... understand the Department's information collection requirements and provide the requested data in the desired...

  2. The Moss Techniques for Air Pollution Study in Bulgaria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marinova, S.; Marinov, A.; Frontasyeva, M.

    2010-01-21

    The paper presents new results on atmospheric deposition of 41 elements in four areas of Bulgaria during the European moss survey in 2005. The results have been obtained by the moss biomonitoring technique. Ninety seven moss samples were analyzed by instrumental neutron activation analysis (ENAA) and atomic absorption spectrometry (AAS).

  3. Review of analytical methods for the quantification of iodine in complex matrices.

    PubMed

    Shelor, C Phillip; Dasgupta, Purnendu K

    2011-09-19

    Iodine is an essential element of human nutrition. Nearly a third of the global population has insufficient iodine intake and is at risk of developing Iodine Deficiency Disorders (IDD). Most countries have iodine supplementation and monitoring programs. Urinary iodide (UI) is the biomarker used for epidemiological studies; only a few methods are currently used routinely for analysis. These methods either require expensive instrumentation with qualified personnel (inductively coupled plasma-mass spectrometry, instrumental nuclear activation analysis) or oxidative sample digestion to remove potential interferences prior to analysis by a kinetic colorimetric method originally introduced by Sandell and Kolthoff ~75 years ago. The Sandell-Kolthoff (S-K) method is based on the catalytic effect of iodide on the reaction between Ce(4+) and As(3+). No available technique fully fits the needs of developing countries; research into inexpensive reliable methods and instrumentation are needed. There have been multiple reviews of methods used for epidemiological studies and specific techniques. However, a general review of iodine determination on a wide-ranging set of complex matrices is not available. While this review is not comprehensive, we cover the principal developments since the original development of the S-K method. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Generic patient-reported outcomes in child health research: a review of conceptual content using World Health Organization definitions.

    PubMed

    Fayed, Nora; de Camargo, Olaf Kraus; Kerr, Elizabeth; Rosenbaum, Peter; Dubey, Ankita; Bostan, Cristina; Faulhaber, Markus; Raina, Parminder; Cieza, Alarcos

    2012-12-01

    Our aims were to (1) describe the conceptual basis of popular generic instruments according to World Health Organization (WHO) definitions of functioning, disability, and health (FDH), and quality of life (QOL) with health-related quality of life (HRQOL) as a subcomponent of QOL; (2) map the instruments to the International Classification of Functioning, Disability and Health (ICF); and (3) provide information on how the analyzed instruments were used in the literature. This should enable users to make valid choices about which instruments have the desired content for a specific context or purpose. Child health-based literature over a 5-year period was reviewed to find research employing health status and QOL/HRQOL instruments. WHO definitions of FDH and QOL were applied to each item of the 15 most used instruments to differentiate measures of FDH and QOL/HRQOL. The ICF was used to describe the health and health-related content (if any) in those instruments. Additional aspects of instrument use were extracted from these articles. Many instruments that were used to measure QOL/HRQOL did not reflect WHO definitions of QOL. The ICF domains within instruments were highly variable with respect to whether body functions, activities and participation, or environment were emphasized. There is inconsistency among researchers about how to measure HRQOL and QOL. Moreover, when an ICF content analysis is applied, there is variability among instruments in the health components included and emphasized. Reviewing content is important for matching instruments to their intended purpose. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.

  5. Smartphone Analytics: Mobilizing the Lab into the Cloud for Omic-Scale Analyses.

    PubMed

    Montenegro-Burke, J Rafael; Phommavongsay, Thiery; Aisporna, Aries E; Huan, Tao; Rinehart, Duane; Forsberg, Erica; Poole, Farris L; Thorgersen, Michael P; Adams, Michael W W; Krantz, Gregory; Fields, Matthew W; Northen, Trent R; Robbins, Paul D; Niedernhofer, Laura J; Lairson, Luke; Benton, H Paul; Siuzdak, Gary

    2016-10-04

    Active data screening is an integral part of many scientific activities, and mobile technologies have greatly facilitated this process by minimizing the reliance on large hardware instrumentation. In order to meet with the increasingly growing field of metabolomics and heavy workload of data processing, we designed the first remote metabolomic data screening platform for mobile devices. Two mobile applications (apps), XCMS Mobile and METLIN Mobile, facilitate access to XCMS and METLIN, which are the most important components in the computer-based XCMS Online platforms. These mobile apps allow for the visualization and analysis of metabolic data throughout the entire analytical process. Specifically, XCMS Mobile and METLIN Mobile provide the capabilities for remote monitoring of data processing, real time notifications for the data processing, visualization and interactive analysis of processed data (e.g., cloud plots, principle component analysis, box-plots, extracted ion chromatograms, and hierarchical cluster analysis), and database searching for metabolite identification. These apps, available on Apple iOS and Google Android operating systems, allow for the migration of metabolomic research onto mobile devices for better accessibility beyond direct instrument operation. The utility of XCMS Mobile and METLIN Mobile functionalities was developed and is demonstrated here through the metabolomic LC-MS analyses of stem cells, colon cancer, aging, and bacterial metabolism.

  6. Smartphone Analytics: Mobilizing the Lab into the Cloud for Omic-Scale Analyses

    PubMed Central

    2016-01-01

    Active data screening is an integral part of many scientific activities, and mobile technologies have greatly facilitated this process by minimizing the reliance on large hardware instrumentation. In order to meet with the increasingly growing field of metabolomics and heavy workload of data processing, we designed the first remote metabolomic data screening platform for mobile devices. Two mobile applications (apps), XCMS Mobile and METLIN Mobile, facilitate access to XCMS and METLIN, which are the most important components in the computer-based XCMS Online platforms. These mobile apps allow for the visualization and analysis of metabolic data throughout the entire analytical process. Specifically, XCMS Mobile and METLIN Mobile provide the capabilities for remote monitoring of data processing, real time notifications for the data processing, visualization and interactive analysis of processed data (e.g., cloud plots, principle component analysis, box-plots, extracted ion chromatograms, and hierarchical cluster analysis), and database searching for metabolite identification. These apps, available on Apple iOS and Google Android operating systems, allow for the migration of metabolomic research onto mobile devices for better accessibility beyond direct instrument operation. The utility of XCMS Mobile and METLIN Mobile functionalities was developed and is demonstrated here through the metabolomic LC-MS analyses of stem cells, colon cancer, aging, and bacterial metabolism. PMID:27560777

  7. Smartphone Analytics: Mobilizing the Lab into the Cloud for Omic-Scale Analyses

    DOE PAGES

    Montenegro-Burke, J. Rafael; Phommavongsay, Thiery; Aisporna, Aries E.; ...

    2016-08-25

    Active data screening is an integral part of many scientific activities, and mobile technologies have greatly facilitated this process by minimizing the reliance on large hardware instrumentation. In order to meet with the increasingly growing field of metabolomics and heavy workload of data processing, we designed the first remote metabolomic data screening platform for mobile devices. Two mobile applications (apps), XCMS Mobile and METLIN Mobile, facilitate access to XCMS and METLIN, which are the most important components in the computer-based XCMS Online platforms. These mobile apps allow for the visualization and analysis of metabolic data throughout the entire analytical process.more » Specifically, XCMS Mobile and METLIN Mobile provide the capabilities for remote monitoring of data processing, real time notifications for the data processing, visualization and interactive analysis of processed data (e.g., cloud plots, principle component analysis, box-plots, extracted ion chromatograms, and hierarchical cluster analysis), and database searching for metabolite identification. These apps, available on Apple iOS and Google Android operating systems, allow for the migration of metabolomic research onto mobile devices for better accessibility beyond direct instrument operation. The utility of XCMS Mobile and METLIN Mobile functionalities was developed and is demonstrated here through the metabolomic LC-MS analyses of stem cells, colon cancer, aging, and bacterial metabolism.« less

  8. Smartphone Analytics: Mobilizing the Lab into the Cloud for Omic-Scale Analyses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Montenegro-Burke, J. Rafael; Phommavongsay, Thiery; Aisporna, Aries E.

    Active data screening is an integral part of many scientific activities, and mobile technologies have greatly facilitated this process by minimizing the reliance on large hardware instrumentation. In order to meet with the increasingly growing field of metabolomics and heavy workload of data processing, we designed the first remote metabolomic data screening platform for mobile devices. Two mobile applications (apps), XCMS Mobile and METLIN Mobile, facilitate access to XCMS and METLIN, which are the most important components in the computer-based XCMS Online platforms. These mobile apps allow for the visualization and analysis of metabolic data throughout the entire analytical process.more » Specifically, XCMS Mobile and METLIN Mobile provide the capabilities for remote monitoring of data processing, real time notifications for the data processing, visualization and interactive analysis of processed data (e.g., cloud plots, principle component analysis, box-plots, extracted ion chromatograms, and hierarchical cluster analysis), and database searching for metabolite identification. These apps, available on Apple iOS and Google Android operating systems, allow for the migration of metabolomic research onto mobile devices for better accessibility beyond direct instrument operation. The utility of XCMS Mobile and METLIN Mobile functionalities was developed and is demonstrated here through the metabolomic LC-MS analyses of stem cells, colon cancer, aging, and bacterial metabolism.« less

  9. Fiscal Year (FY) 2017 Activities for the Spent Fuel Nondestructive Assay Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trellue, Holly Renee; Trahan, Alexis Chanel; McMath, Garrett Earl

    The main focus of research in the NA-241 spent fuel nondestructive assay (NDA) project in FY17 has been completing the fabrication and testing of two prototype instruments for upcoming spent fuel measurements at the Clab interim storage facility in Sweden. One is a passive instrument: Differential Die-away Self Interrogation-Passive Neutron Albedo Reactivity (DDSI), and one is an active instrument: Differential Die-Away-Californium Interrogation with Prompt Neutron (DDA). DDSI was fabricated and tested with fresh fuel at Los Alamos National Laboratory in FY15 and FY16, then shipped to Sweden at the beginning of FY17. Research was performed in FY17 to simplify resultsmore » from the data acquisition system, which is complex because signals from 56 different 3He detectors must be processed using list mode data. The DDA instrument was fabricated at the end of FY16. New high count rate electronics better suited for a spent fuel environment (i.e., KM-200 preamplifiers) were built specifically for this instrument in FY17, and new Tygon tubing to house electrical cables was purchased and installed. Fresh fuel tests using the DDA instrument with numerous configurations of fuel rods containing depleted uranium (DU), low enriched uranium (LEU), and LEU with burnable poisons (Gd) were successfully performed and compared to simulations.1 Additionally, members of the spent fuel NDA project team travelled to Sweden for a “spent fuel characterization and decay heat” workshop involving simulations of spent fuel and analysis of uncertainties in decay heat calculations.« less

  10. ANALOG I/O MODULE TEST SYSTEM BASED ON EPICS CA PROTOCOL AND ACTIVEX CA INTERFACE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    YENG,YHOFF,L.

    2003-10-13

    Analog input (ADC) and output (DAC) modules play a substantial role in device level control of accelerator and large experiment physics control system. In order to get the best performance some features of analog modules including linearity, accuracy, crosstalk, thermal drift and so on have to be evaluated during the preliminary design phase. Gain and offset error calibration and thermal drift compensation (if needed) may have to be done in the implementation phase as well. A natural technique for performing these tasks is to interface the analog VO modules and GPIB interface programmable test instruments with a computer, which canmore » complete measurements or calibration automatically. A difficulty is that drivers of analog modules and test instruments usually work on totally different platforms (vxworks VS Windows). Developing new test routines and drivers for testing instruments under VxWorks (or any other RTOS) platform is not a good solution because such systems have relatively poor user interface and developing such software requires substantial effort. EPICS CA protocol and ActiveX CA interface provide another choice, a PC and LabVIEW based test system. Analog 110 module can be interfaced from LabVIEW test routines via ActiveX CA interface. Test instruments can be controlled via LabVIEW drivers, most of which are provided by instrument vendors or by National Instruments. Labview also provides extensive data analysis and process functions. Using these functions, users can generate powerful test routines very easily. Several applications built for Spallation Neutron Source (SNS) Beam Loss Monitor (BLM) system are described in this paper.« less

  11. Instrument characterization for the detection of long-term changes in stratospheric ozone - An analysis of the SBUV/2 radiometer

    NASA Technical Reports Server (NTRS)

    Frederick, J. E.; Heath, D. F.; Cebula, R. P.

    1986-01-01

    The scientific objective of unambiguously detecting subtle global trends in upper stratospheric ozone requires that one maintains a thorough understanding of the satellite-based remote sensors intended for this task. The instrument now in use for long term ozone monitoring is the SBUV/2 being flown on NOAA operational satellites. A critical activity in the data interpretation involves separating small changes in measurement sensitivity from true atmospheric variability. By defining the specific issues that must be addressed and presenting results derived early in the mission of the first SBUV/2 flight model, this work serves as a guide to the instrument investigations that are essential in the attempt to detect long-term changes in the ozone layer.

  12. Lightning Protection and Instrumentation at Kennedy Space Center

    NASA Technical Reports Server (NTRS)

    Colon, Jose L.

    2005-01-01

    Lightning is a natural phenomenon, but can be dangerous. Prevention of lightning is a physical impossibility and total protection requires compromises on costs and effects, therefore prediction and measurements of the effects that might be produced by iightn:ing is a most at locat:ions where people or sensitive systems and equipment are exposed. This is the case of the launching pads for the Space Shuttle at Kennedy Space Center (KSC) of the National Aeronautics and Space Administration. This report summarizes lightring phenomena with a brief explanation of lightning generation and lightning activity as related to KSC. An analysis of the instrumentation used at the launching pads for measurements of lightning effects with alternatives to improve the protection system and up-grade the actual instrumentation system is indicated.

  13. Common observations of solar X-rays from SPHINX/CORONAS-PHOTON and XRS/MESSENGER

    NASA Astrophysics Data System (ADS)

    Kepa, Anna; Sylwester, Janusz; Sylwester, Barbara; Siarkowski, Marek; Mrozek, Tomasz; Gryciuk, Magdalena; Phillips, Kenneth

    SphinX was a soft X-ray spectrophotometer constructed in the Space Research Centre of Polish Academy of Sciences. The instrument was launched on 30 January 2009 aboard CORONAS-PHOTON satellite as a part of TESIS instrument package. SphinX measured total solar X-ray flux in the energy range from 1 to 15 keV during the period of very low solar activity from 20 February to 29 November 2009. For these times the solar detector (X-ray Spectrometer - XRS) onboard MESSENGER also observed the solar X-rays from a different vantage point. XRS measured the radiation in similar energy range. We present results of the comparison of observations from both instruments and show the preliminary results of physical analysis of spectra for selected flares.

  14. Comparison of Collisional and Electron-Based Dissociation Modes for Middle-Down Analysis of Multiply Glycosylated Peptides

    NASA Astrophysics Data System (ADS)

    Khatri, Kshitij; Pu, Yi; Klein, Joshua A.; Wei, Juan; Costello, Catherine E.; Lin, Cheng; Zaia, Joseph

    2018-04-01

    Analysis of singly glycosylated peptides has evolved to a point where large-scale LC-MS analyses can be performed at almost the same scale as proteomics experiments. While collisionally activated dissociation (CAD) remains the mainstay of bottom-up analyses, it performs poorly for the middle-down analysis of multiply glycosylated peptides. With improvements in instrumentation, electron-activated dissociation (ExD) modes are becoming increasingly prevalent for proteomics experiments and for the analysis of fragile modifications such as glycosylation. While these methods have been applied for glycopeptide analysis in isolated studies, an organized effort to compare their efficiencies, particularly for analysis of multiply glycosylated peptides (termed here middle-down glycoproteomics), has not been made. We therefore compared the performance of different ExD modes for middle-down glycopeptide analyses. We identified key features among the different dissociation modes and show that increased electron energy and supplemental activation provide the most useful data for middle-down glycopeptide analysis. [Figure not available: see fulltext.

  15. Trace-element analysis of 1000 environmental samples per year using instrumental neutron activation analysis

    NASA Technical Reports Server (NTRS)

    Sheibley, D. W.

    1974-01-01

    The technology and methods developed at the Plum Brook Reactor to analyze 1000 samples per year and report data on as many as 56 elements are described. The manpower for the complete analysis of 20 to 24 samples per week required only 3 to 3.5 hours per sample. The solutions to problems encountered in sample preparation, irradiation, and counting are discussed. The automation of data reduction is described. Typical data on various sample matrices are presented.

  16. Miniature Neutron-Alpha Activation Spectrometer

    NASA Astrophysics Data System (ADS)

    Rhodes, E.; Goldsten, J.

    2001-01-01

    We are developing a miniature neutron-alpha activation spectrometer for in situ analysis of samples including rocks, fines, ices, and drill cores, suitable for a lander or Rover platform, that would meet the severe mass, power, and environmental constraints of missions to the outer planets. In the neutron-activation mode, a gamma-ray spectrometer will first perform a penetrating scan of soil, ice, and loose material underfoot (depths to 10 cm or more) to identify appropriate samples. Chosen samples will be analyzed in bulk in neutron-activation mode, and then the sample surfaces will be analyzed in alpha-activation mode using Rutherford backscatter and x-ray spectrometers. The instrument will provide sample composition over a wide range of elements, including rock-forming elements (such as Na, Mg, Si, Fe, and Ca), rare earths (Sm and Eu for example), radioactive elements (K, Th, and U), and light elements present in water, ices, and biological materials (mainly H, C, O, and N). The instrument is expected to have a mass of about l kg and to require less than 1 W power. Additional information is contained in the original extended abstract.

  17. Measurement of activity limitations and participation restrictions: examination of ICF-linked content and scale properties of the FIM and PC-PART instruments.

    PubMed

    Darzins, Susan W; Imms, Christine; Di Stefano, Marilyn

    2017-05-01

    To explore the operationalization of activity and participation-related measurement constructs through comparison of item phrasing, item response categories and scoring (scale properties) for two separate instruments targeting activities of daily living. Personal Care Participation Assessment and Resource Tool (PC-PART) item content was linked to ICF categories using established linking rules. Previously reported ICF-linked FIM content categories and ICF-linked PC-PART content categories were compared to identify common ICF categories between the instruments. Scale properties of both instruments were compared using a patient scenario to explore the instruments' separate measurement constructs. The PC-PART and FIM shared 15 of the 53 level two ICF-linked categories identified across both instruments. Examination of the instruments' scale properties for items with overlapping ICF content, and exploration through a patient scenario, provided supportive evidence that the instruments measure different constructs. While the PC-PART and FIM share common ICF-linked content, they measure separate constructs. Measurement construct was influenced by the instruments' scale properties. The FIM was observed to measure activity limitations and the PC-PART measured participation restrictions. Scrutiny of instruments' scale properties in addition to item content is critical in the operationalization of activity and participation-related measurement constructs. Implications for Rehabilitation When selecting outcome measures for use in rehabilitation it is necessary to examine both the content of the instruments' items and item phrasing, response categories and scoring, to clarify the construct being measured. Measurement of activity limitations as well as participation restrictions in activities of daily living required for community life provides a more comprehensive measurement of rehabilitation outcomes than measurement of either construct alone. To measure the effects of interventions used in rehabilitation, it is necessary to select measures with relevant content and scale properties that enable evaluation of change in the constructs that are expected to change, as a result of the rehabilitation intervention.

  18. Determination of 30 elements in coal and fly ash by thermal and epithermal neutron-activation analysis

    USGS Publications Warehouse

    Rowe, J.J.; Steinnes, E.

    1977-01-01

    Thirty elements are determined in coal and fly ash by instrumental neutron-activation analysis using both thermal and epithermal irradiation. Gamma-ray spectra were recorded 7 and 20 days after the irradiations. The procedure is applicable to the routine analysis of coals and fly ash. Epithermal irradiation was found preferable for the determination of Ni, Zn, As, Se, Br, Rb, Sr, Mo, Sb, Cs, Ba, Sm, Tb, Hf, Ta, W, Th and U, whereas thermal irradiation was best for Sc, Cr, Fe, Co, La, Ce, Nd, Eu, Yb and Lu. Results for SRM 1632 (coal) and SRM 1633 (fly ash) agree with those of other investigators. ?? 1977.

  19. Perception of competence in middle school physical education: instrument development and validation.

    PubMed

    Scrabis-Fletcher, Kristin; Silverman, Stephen

    2010-03-01

    Perception of Competence (POC) has been studied extensively in physical activity (PA) research with similar instruments adapted for physical education (PE) research. Such instruments do not account for the unique PE learning environment. Therefore, an instrument was developed and the scores validated to measure POC in middle school PE. A multiphase design was used consisting of an intensive theoretical review, elicitation study, prepilot study, pilot study, content validation study, and final validation study (N=1281). Data analysis included a multistep iterative process to identify the best model fit. A three-factor model for POC was tested and resulted in root mean square error of approximation = .09, root mean square residual = .07, goodness offit index = .90, and adjusted goodness offit index = .86 values in the acceptable range (Hu & Bentler, 1999). A two-factor model was also tested and resulted in a good fit (two-factor fit indexes values = .05, .03, .98, .97, respectively). The results of this study suggest that an instrument using a three- or two-factor model provides reliable and valid scores ofPOC measurement in middle school PE.

  20. Systematic Refinement of a Health Information Technology Time and Motion Workflow Instrument for Inpatient Nursing Care using a Standardized Interface Terminology

    PubMed Central

    Zhang, Yi; Monsen, Karen A; Adam, Terrence J; Pieczkiewicz, David S; Daman, Megan; Melton, Genevieve B

    2011-01-01

    Time and motion (T&M) studies provide an objective method to measure the expenditure of time by clinicians. While some instruments for T&M studies have been designed to evaluate health information technology (HIT), these instruments have not been designed for nursing workflow. We took an existing open source HIT T&M study application designed to evaluate physicians in the ambulatory setting and rationally adapted it through empiric observations to record nursing activities in the inpatient setting and linked this instrument to an existing interface terminology, the Omaha System. Nursing activities involved several dimensions and could include multiple activities occurring simultaneously, requiring significant instrument redesign. 94% of the activities from the study instrument mapped adequately to the Omaha System. T&M study instruments require customization in design optimize them for different environments, such as inpatient nursing, to enable optimal data collection. Interface terminologies show promise as a framework for recording and analyzing T&M study data. PMID:22195228

  1. Using Hierarchical Models of Studying To Evaluate the Character of Students' Study Activities.

    ERIC Educational Resources Information Center

    Warkentin, Robert W.; And Others

    An instrument was developed to measure students' engagement in various classes of study activities within multiple study contexts. This instrument is to be used in a large, ongoing research project investigating the underpinnings of student study activities and effects on academic achievement. The computer-administered instrument used--the Study…

  2. Characterization of a new qQq-FTICR mass spectrometer for post-translational modification analysis and top-down tandem mass spectrometry of whole proteins.

    PubMed

    Jebanathirajah, Judith A; Pittman, Jason L; Thomson, Bruce A; Budnik, Bogdan A; Kaur, Parminder; Rape, Michael; Kirschner, Marc; Costello, Catherine E; O'Connor, Peter B

    2005-12-01

    The use of a new electrospray qQq Fourier transform ion cyclotron mass spectrometer (qQq-FTICR MS) instrument for biologic applications is described. This qQq-FTICR mass spectrometer was designed for the study of post-translationally modified proteins and for top-down analysis of biologically relevant protein samples. The utility of the instrument for the analysis of phosphorylation, a common and important post-translational modification, was investigated. Phosphorylation was chosen as an example because it is ubiquitous and challenging to analyze. In addition, the use of the instrument for top-down sequencing of proteins was explored since this instrument offers particular advantages to this approach. Top-down sequencing was performed on different proteins, including commercially available proteins and biologically derived samples such as the human E2 ubiquitin conjugating enzyme, UbCH10. A good sequence tag was obtained for the human UbCH10, allowing the unambiguous identification of the protein. The instrument was built with a commercially produced front end: a focusing rf-only quadrupole (Q0), followed by a resolving quadrupole (Q1), and a LINAC quadrupole collision cell (Q2), in combination with an FTICR mass analyzer. It has utility in the analysis of samples found in substoichiometric concentrations, as ions can be isolated in the mass resolving Q1 and accumulated in Q2 before analysis in the ICR cell. The speed and efficacy of the Q2 cooling and fragmentation was demonstrated on an LCMS-compatible time scale, and detection limits for phosphopeptides in the 10 amol/muL range (pM) were demonstrated. The instrument was designed to make several fragmentation methods available, including nozzle-skimmer fragmentation, Q2 collisionally activated dissociation (Q2 CAD), multipole storage assisted dissociation (MSAD), electron capture dissociation (ECD), infrared multiphoton induced dissociation (IRMPD), and sustained off resonance irradiation (SORI) CAD, thus allowing a variety of MS(n) experiments. A particularly useful aspect of the system was the use of Q1 to isolate ions from complex mixtures with narrow windows of isolation less than 1 m/z. These features enable top-down protein analysis experiments as well structural characterization of minor components of complex mixtures.

  3. Risk prediction in the community: A systematic review of case-finding instruments that predict adverse healthcare outcomes in community-dwelling older adults.

    PubMed

    O'Caoimh, Rónán; Cornally, Nicola; Weathers, Elizabeth; O'Sullivan, Ronan; Fitzgerald, Carol; Orfila, Francesc; Clarnette, Roger; Paúl, Constança; Molloy, D William

    2015-09-01

    Few case-finding instruments are available to community healthcare professionals. This review aims to identify short, valid instruments that detect older community-dwellers risk of four adverse outcomes: hospitalisation, functional-decline, institutionalisation and death. Data sources included PubMed and the Cochrane library. Data on outcome measures, patient and instrument characteristics, and trial quality (using the Quality In Prognosis Studies [QUIPS] tool), were double-extracted for derivation-validation studies in community-dwelling older adults (>50 years). Forty-six publications, representing 23 unique instruments, were included. Only five were externally validated. Mean patient age range was 64.2-84.6 years. Most instruments n=18, (78%) were derived in North America from secondary analysis of survey data. The majority n=12, (52%), measured more than one outcome with hospitalisation and the Probability of Repeated Admission score the most studied outcome and instrument respectively. All instruments incorporated multiple predictors. Activities of daily living n=16, (70%), was included most often. Accuracy varied according to instruments and outcomes; area under the curve of 0.60-0.73 for hospitalisation, 0.63-0.78 for functional decline, 0.70-0.74 for institutionalisation and 0.56-0.82 for death. The QUIPS tool showed that 5/23 instruments had low potential for bias across all domains. This review highlights the present need to develop short, reliable, valid instruments to case-find older adults at risk in the community. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  4. Psychometric Principles in Measurement for Geoscience Education Research: A Climate Change Example

    NASA Astrophysics Data System (ADS)

    Libarkin, J. C.; Gold, A. U.; Harris, S. E.; McNeal, K.; Bowles, R.

    2015-12-01

    Understanding learning in geoscience classrooms requires that we use valid and reliable instruments aligned with intended learning outcomes. Nearly one hundred instruments assessing conceptual understanding in undergraduate science and engineering classrooms (often called concept inventories) have been published and are actively being used to investigate learning. The techniques used to develop these instruments vary widely, often with little attention to psychometric principles of measurement. This paper will discuss the importance of using psychometric principles to design, evaluate, and revise research instruments, with particular attention to the validity and reliability steps that must be undertaken to ensure that research instruments are providing meaningful measurement. An example from a climate change inventory developed by the authors will be used to exemplify the importance of validity and reliability, including the value of item response theory for instrument development. A 24-item instrument was developed based on published items, conceptions research, and instructor experience. Rasch analysis of over 1000 responses provided evidence for the removal of 5 items for misfit and one item for potential bias as measured via differential item functioning. The resulting 18-item instrument can be considered a valid and reliable measure based on pre- and post-implementation metrics. Consideration of the relationship between respondent demographics and concept inventory scores provides unique insight into the relationship between gender, religiosity, values and climate change understanding.

  5. Inflight proton activation and damage on a CdTe detection plane

    NASA Astrophysics Data System (ADS)

    Simões, N.; Maia, J. M.; Curado da Silva, R. M.; Ghithan, S.; Crespo, P.; do Carmo, S. J. C.; Alves, Francisco; Moita, M.; Auricchio, N.; Caroli, E.

    2018-01-01

    Future high-energy space telescope missions require further analysis of orbital environment induced activation and radiation damage on main instruments. A scientific satellite is exposed to the charged particles harsh environment, mainly geomagnetically trapped protons (up to ∼300 MeV) that interact with the payload materials, generating nuclear activation background noise within instruments' operational energy range and causing radiation damage in detector material. As a consequence, instruments' performances deteriorate during the mission time-frame. In order to optimize inflight operational performances of future CdTe high-energy telescope detection planes under orbital radiation environment, we measured and analyzed the effects generated by protons on CdTe ACRORAD detectors with 2.56 cm2 sensitive area and 2 mm thickness. To carry-out this study, several sets of measurements were performed under a ∼14 MeV cyclotron proton beam. Nuclear activation radionuclides' identification was performed. Estimation of activation background generated by short-lived radioisotopes during one day was less than ∼1.3 ×10-5 counts cm-2 s-1 keV-1 up to 800 keV. A noticeable gamma-rays energy resolution degradation was registered (∼60% @ 122 keV, ∼14% @ 511 and ∼2.2% @ 1275 keV) after an accumulated proton fluence of 4.5 ×1010 protons cm-2, equivalent to ∼22 years in-orbit fluence. One year later, the energy resolution of the irradiated prototype showed a good level of performancerecovery.

  6. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments.

    PubMed

    Pasternak, Braulio; Sousa Neto, Manoel Damião de; Dionísio, Valdeci Carlos; Pécora, Jesus Djalma; Silva, Ricardo Gariba

    2012-02-01

    This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.

  7. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments

    PubMed Central

    PASTERNAK-JÚNIOR, Braulio; de SOUSA NETO, Manoel Damião; DIONÍSIO, Valdeci Carlos; PÉCORA, Jesus Djalma; SILVA, Ricardo Gariba

    2012-01-01

    Objective This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques. PMID:22437679

  8. Perceptual Characterization and Analysis of Aroma Mixtures Using Gas Chromatography Recomposition-Olfactometry

    PubMed Central

    Johnson, Arielle J.; Hirson, Gregory D.; Ebeler, Susan E.

    2012-01-01

    This paper describes the design of a new instrumental technique, Gas Chromatography Recomposition-Olfactometry (GC-R), that adapts the reconstitution technique used in flavor chemistry studies by extracting volatiles from a sample by headspace solid-phase microextraction (SPME), separating the extract on a capillary GC column, and recombining individual compounds selectively as they elute off of the column into a mixture for sensory analysis (Figure 1). Using the chromatogram of a mixture as a map, the GC-R instrument allows the operator to “cut apart" and recombine the components of the mixture at will, selecting compounds, peaks, or sections based on retention time to include or exclude in a reconstitution for sensory analysis. Selective recombination is accomplished with the installation of a Deans Switch directly in-line with the column, which directs compounds either to waste or to a cryotrap at the operator's discretion. This enables the creation of, for example, aroma reconstitutions incorporating all of the volatiles in a sample, including instrumentally undetectable compounds as well those present at concentrations below sensory thresholds, thus correcting for the “reconstitution discrepancy" sometimes noted in flavor chemistry studies. Using only flowering lavender (Lavandula angustifola ‘Hidcote Blue’) as a source for volatiles, we used the instrument to build mixtures of subsets of lavender volatiles in-instrument and characterized their aroma qualities with a sensory panel. We showed evidence of additive, masking, and synergistic effects in these mixtures and of “lavender' aroma character as an emergent property of specific mixtures. This was accomplished without the need for chemical standards, reductive aroma models, or calculation of Odor Activity Values, and is broadly applicable to any aroma or flavor. PMID:22912722

  9. Perceptual characterization and analysis of aroma mixtures using gas chromatography recomposition-olfactometry.

    PubMed

    Johnson, Arielle J; Hirson, Gregory D; Ebeler, Susan E

    2012-01-01

    This paper describes the design of a new instrumental technique, Gas Chromatography Recomposition-Olfactometry (GC-R), that adapts the reconstitution technique used in flavor chemistry studies by extracting volatiles from a sample by headspace solid-phase microextraction (SPME), separating the extract on a capillary GC column, and recombining individual compounds selectively as they elute off of the column into a mixture for sensory analysis (Figure 1). Using the chromatogram of a mixture as a map, the GC-R instrument allows the operator to "cut apart" and recombine the components of the mixture at will, selecting compounds, peaks, or sections based on retention time to include or exclude in a reconstitution for sensory analysis. Selective recombination is accomplished with the installation of a Deans Switch directly in-line with the column, which directs compounds either to waste or to a cryotrap at the operator's discretion. This enables the creation of, for example, aroma reconstitutions incorporating all of the volatiles in a sample, including instrumentally undetectable compounds as well those present at concentrations below sensory thresholds, thus correcting for the "reconstitution discrepancy" sometimes noted in flavor chemistry studies. Using only flowering lavender (Lavandula angustifola 'Hidcote Blue') as a source for volatiles, we used the instrument to build mixtures of subsets of lavender volatiles in-instrument and characterized their aroma qualities with a sensory panel. We showed evidence of additive, masking, and synergistic effects in these mixtures and of "lavender' aroma character as an emergent property of specific mixtures. This was accomplished without the need for chemical standards, reductive aroma models, or calculation of Odor Activity Values, and is broadly applicable to any aroma or flavor.

  10. Physical activity and adolescents: an exploratory randomized controlled trial investigating the influence of affective and instrumental text messages.

    PubMed

    Sirriyeh, Reema; Lawton, Rebecca; Ward, Jane

    2010-11-01

    The present study attempts to develop and pilot the feasibility and efficacy of a novel intervention using affective messages as a strategy to increase physical activity (PA) levels in adolescents. Design An exploratory pilot randomized control trial was used to compare behaviour change over 2 weeks. A modified form of the International Physical Activity Questionnaire was used to assess PA behaviour. A total of 120 adolescents (16-19 years) from 4 sixth forms in West Yorkshire completed the field-based study. Participants were randomly assigned to one of three experimental conditions, or the control condition (N=28). Participants in experimental conditions received 1 short messaging service (SMS) text message per day over the 2 weeks, which included manipulations of either affective beliefs (enjoyable/unenjoyable; N=31), instrumental beliefs (beneficial/harmful; N=30), or a combination of these (N=31). Control participants received one SMS text message per week. Outcomes were measured at baseline and at the end of the 2 week intervention. PA levels increased by the equivalent of 31.5  minutes of moderate (four metabolic equivalent) activity per week during the study. Main effects of condition (p=.049), and current physical activity level (p=.002) were identified, along with a significant interaction between condition and current activity level (p=.006). However, when the sample was split at baseline into active and inactive participants, a main effect of condition remained for inactive participants only (p=.001). Post hoc analysis revealed that inactive participants who received messages targeting affective beliefs increased their activity levels significantly more than the instrumental (p=.012), combined (p=.002), and control groups (p=.018). Strategies based on affective associations may be more effective for increasing PA levels in inactive individuals.

  11. Costs and effects in lumbar spinal fusion. A follow-up study in 136 consecutive patients with chronic low back pain

    PubMed Central

    Christensen, Finn Bjarke; Christiansen, Terkel; Bünger, Cody

    2006-01-01

    Although cost-effectiveness is becoming the foremost evaluative criterion within health service management of spine surgery, scientific knowledge about cost-patterns and cost-effectiveness is limited. The aims of this study were (1) to establish an activity-based method for costing at the patient-level, (2) to investigate the correlation between costs and effects, (3) to investigate the influence of selected patient characteristics on cost-effectiveness and, (4) to investigate the incremental cost-effectiveness ratio of (a) posterior instrumentation and (b) intervertebral anterior support in lumbar spinal fusion. We hypothesized a positive correlation between costs and effects, that determinants of effects would also determine cost-effectiveness, and that posterolateral instrumentation and anterior intervertebral support are cost-effective adjuncts in posterolateral lumbar fusion. A cohort of 136 consecutive patients with chronic low back pain, who were surgically treated from January 2001 through January 2003, was followed until 2 years postoperatively. Operations took place at University Hospital of Aarhus and all patients had either (1) non-instrumented posterolateral lumbar spinal fusion, (2) instrumented posterolateral lumbar spinal fusion, or (3) instrumented posterolateral lumbar spinal fusion + anterior intervertebral support. Analysis of costs was performed at the patient-level, from an administrator’s perspective, by means of Activity-Based-Costing. Clinical effects were measured by means of the Dallas Pain Questionnaire and the Low Back Pain Rating Scale at baseline and 2 years postoperatively. Regression models were used to reveal determinants for costs and effects. Costs and effects were analyzed as a net-benefit measure to reveal determinants for cost-effectiveness, and finally, adjusted analysis (for non-random allocation of patients) was performed in order to reveal the incremental cost-effectiveness ratios of (a) posterior instrumentation and (b) anterior support. The costs of non-instrumented posterolateral spinal fusion were estimated at DKK 88,285(95% CI 81,369;95,546), instrumented posterolateral spinal fusion at DKK 94,396(95% CI 89,865;99,574) and instrumented posterolateral lumbar spinal fusion + anterior intervertebral support at DKK 120,759(95% CI 111,981;133,738). The net-benefit of the regimens was significantly affected by smoking and functional disability in psychosocial life areas. Multi-level fusion and surgical technique significantly affected the net-benefit as well. Surprisingly, no correlation was found between treatment costs and treatment effects. Incremental analysis suggested that the probability of posterior instrumentation being cost-effective was limited, whereas the probability of anterior intervertebral support being cost-effective escalates as willingness-to-pay per effect unit increases. This study reveals useful and hitherto unknown information both about cost-patterns at the patient-level and determinants of cost-effectiveness. The overall conclusion of the present investigation is a recommendation to focus further on determinants of cost-effectiveness. For example, patient characteristics that are modifiable at a relatively low expense may have greater influence on cost-effectiveness than the surgical technique itself—at least from an administrator’s perspective. PMID:16871387

  12. The development and exploratory analysis of the Back Pain Attitudes Questionnaire (Back-PAQ)

    PubMed Central

    Darlow, Ben; Perry, Meredith; Mathieson, Fiona; Stanley, James; Melloh, Markus; Marsh, Reginald; Baxter, G David; Dowell, Anthony

    2014-01-01

    Objectives To develop an instrument to assess attitudes and underlying beliefs about back pain, and subsequently investigate its internal consistency and underlying structures. Design The instrument was developed by a multidisciplinary team of clinicians and researchers based on analysis of qualitative interviews with people experiencing acute and chronic back pain. Exploratory analysis was conducted using data from a population-based cross-sectional survey. Setting Qualitative interviews with community-based participants and subsequent postal survey. Participants Instrument development informed by interviews with 12 participants with acute back pain and 11 participants with chronic back pain. Data for exploratory analysis collected from New Zealand residents and citizens aged 18 years and above. 1000 participants were randomly selected from the New Zealand Electoral Roll. 602 valid responses were received. Measures The 34-item Back Pain Attitudes Questionnaire (Back-PAQ) was developed. Internal consistency was evaluated by the Cronbach α coefficient. Exploratory analysis investigated the structure of the data using Principal Component Analysis. Results The 34-item long form of the scale had acceptable internal consistency (α=0.70; 95% CI 0.66 to 0.73). Exploratory analysis identified five two-item principal components which accounted for 74% of the variance in the reduced data set: ‘vulnerability of the back’; ‘relationship between back pain and injury’; ‘activity participation while experiencing back pain’; ‘prognosis of back pain’ and ‘psychological influences on recovery’. Internal consistency was acceptable for the reduced 10-item scale (α=0.61; 95% CI 0.56 to 0.66) and the identified components (α between 0.50 and 0.78). Conclusions The 34-item long form of the scale may be appropriate for use in future cross-sectional studies. The 10-item short form may be appropriate for use as a screening tool, or an outcome assessment instrument. Further testing of the 10-item Back-PAQ's construct validity, reliability, responsiveness to change and predictive ability needs to be conducted. PMID:24860003

  13. Cassini Camera Contamination Anomaly: Experiences and Lessons Learned

    NASA Technical Reports Server (NTRS)

    Haemmerle, Vance R.; Gerhard, James H.

    2006-01-01

    We discuss the contamination 'Haze' anomaly for the Cassini Narrow Angle Camera (NAC), one of two optical telescopes that comprise the Imaging Science Subsystem (ISS). Cassini is a Saturn Orbiter with a 4-year nominal mission. The incident occurred in 2001, five months after Jupiter encounter during the Cruise phase and ironically at the resumption of planned maintenance decontamination cycles. The degraded optical performance was first identified by the Instrument Operations Team with the first ISS Saturn imaging six weeks later. A distinct haze of varying size from image to image marred the images of Saturn. A photometric star calibration of the Pleiades, 4 days after the incident, showed stars with halos. Analysis showed that while the halo's intensity was only 1 - 2% of the intensity of the central peak of a star, the halo contained 30 - 70% of its integrated flux. This condition would impact science return. In a review of our experiences, we examine the contamination control plan, discuss the analysis of the limited data available and describe the one-year campaign to remove the haze from the camera. After several long conservative heating activities and interim analysis of their results, the contamination problem as measured by the camera's point spread function was essentially back to preanomaly size and at a point where there would be more risk to continue. We stress the importance of the flexibility of operations and instrument design, the need to do early infight instrument calibration and continual monitoring of instrument performance.

  14. SeaSat-A Satellite Scatterometer (SASS) Validation and Experiment Plan

    NASA Technical Reports Server (NTRS)

    Schroeder, L. C. (Editor)

    1978-01-01

    This plan was generated by the SeaSat-A satellite scatterometer experiment team to define the pre-and post-launch activities necessary to conduct sensor validation and geophysical evaluation. Details included are an instrument and experiment description/performance requirements, success criteria, constraints, mission requirements, data processing requirement and data analysis responsibilities.

  15. Constructing Social Inclusion through Further Education--The Dangers of Instrumentalism

    ERIC Educational Resources Information Center

    Williams, Joanna

    2008-01-01

    This article explores, through an analysis of key policy documents, the construction of the political concepts of social exclusion and inclusion through further education (FE). During the first decade of the New Labour government the concepts of social exclusion and inclusion have undergone a process of active construction. In between "The…

  16. A Comparative Analysis of the Audience for Broadcast Sports and In-Person Sports.

    ERIC Educational Resources Information Center

    Melton, Gary Warren; Galician, Mary-Lou

    A study examined the uses and functions of broadcast sports programming as compared with in-person attendance of sporting events by focusing on the motivations, behavior, and attitudes of audiences toward such activities. Subjects, 219 students from a major western university, completed a survey instrument. Findings indicated that: (1) sports…

  17. 77 FR 28399 - Agency Information Collection Activities: Submission for OMB Review; Comment Request, National...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... standardized reporting methods to collect and analyze fire incident data at the Federal, State, and local levels. Data analysis helps local fire departments and States to focus on current problems, predict..., effort and resources used by respondents to respond) and cost, and the actual data collection instruments...

  18. Formation of Siderite in Lunar Regolith Particles During Irradiation for Instrumental Neutron Activation Analysis

    NASA Technical Reports Server (NTRS)

    Zeigler, R. A.; Haskin, L. A.; Jolliff, B. L.; Wang, A.; Korotev, R. L.

    2002-01-01

    Last year we reported on siderite in an Apollo 16 regolith particle. We ascribed this to vapor deposition on the surface of the Moon by cometary or meteorite impact. Subsequent experiments have shown the siderite to be terrestrial contamination. Additional information is contained in the original extended abstract.

  19. The FOXSI sounding rocket: Latest analysis and results

    NASA Astrophysics Data System (ADS)

    Buitrago-Casas, Juan Camilo; Glesener, Lindsay; Christe, Steven; Krucker, Sam; Ishikawa, Shin-Nosuke; Takahashi, Tadayuki; Ramsey, Brian; Han, Raymond

    2016-05-01

    Hard X-ray (HXR) observations are a linchpin for studying particle acceleration and hot thermal plasma emission in the solar corona. Current and past indirectly imaging instruments lack the sensitivity and dynamic range needed to observe faint HXR signatures, especially in the presences of brighter sources. These limitations are overcome by using HXR direct focusing optics coupled with semiconductor detectors. The Focusing Optics X-ray Solar Imager (FOXSI) sounding rocket experiment is a state of the art solar telescope that develops and applies these capabilities.The FOXSI sounding rocket has successfully flown twice, observing active regions, microflares, and areas of the quiet-Sun. Thanks to its far superior imaging dynamic range, FOXSI performs cleaner hard X-ray imaging spectroscopy than previous instruments that use indirect imaging methods like RHESSI.We present a description of the FOXSI rocket payload, paying attention to the optics and semiconductor detectors calibrations, as well as the upgrades made for the second flight. We also introduce some of the latest FOXSI data analysis, including imaging spectroscopy of microflares and active regions observed during the two flights, and the differential emission measure distribution of the nonflaring corona.

  20. Chemical analysis and antioxidant activity in vitro of polysaccharides extracted from Boletus edulis.

    PubMed

    Zhang, Anqiang; Xiao, Nannan; He, Pengfei; Sun, Peilong

    2011-12-01

    Boletus edulis is a well-known delicious mushroom. In this study, three crude polysaccharides (BEPF30, BEPF60 and BEPF80) were isolated from the fruiting bodies of B. edulis with boiling water. Chemical and physical characteristics of the three crude polysaccharides were investigated by the combination of chemical and instrumental analysis methods. Their antioxidant activities were investigated in vitro systems including hydroxyl assay, superoxide radical assay, reducing power and chelating activity. Among these three polysaccharides, BEPF60 showed more significant reducing power and chelating activity; and highest inhibitory effects on superoxide radical and hydroxyl radical. These results indicated that polysaccharides extracted from B. edulis might be employed as ingredients in healthy and functional food to alleviate the oxidative stress. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Intonation and compensation of fretted string instruments

    NASA Astrophysics Data System (ADS)

    Varieschi, Gabriele; Gower, Christina

    2011-04-01

    We discuss theoretical and physical models that are useful for analyzing the intonation of musical instruments such as guitars and mandolins and can be used to improve the tuning on these instruments. The placement of frets on the fingerboard is designed according to mathematical rules and the assumption of an ideal string. The analysis becomes more complicated when we include the effects of deformation of the string and inharmonicity due to other string characteristics. As a consequence, perfect intonation of all the notes on the instrument cannot be achieved, but complex compensation procedures can be introduced to minimize the problem. To test the validity of these procedures, we performed extensive measurements using standard monochord sonometers and other acoustical devices, confirming the correctness of our theoretical models. These experimental activities can be integrated into acoustics courses and laboratories and can become a more advanced version of basic experiments with monochords and sonometers. This work was supported by a grant from the Frank R. Seaver College of Science and Engineering, Loyola Marymount University.

  2. Optimized merging of search coil and fluxgate data for MMS

    NASA Astrophysics Data System (ADS)

    Fischer, David; Magnes, Werner; Hagen, Christian; Dors, Ivan; Chutter, Mark W.; Needell, Jerry; Torbert, Roy B.; Le Contel, Olivier; Strangeway, Robert J.; Kubin, Gernot; Valavanoglou, Aris; Plaschke, Ferdinand; Nakamura, Rumi; Mirioni, Laurent; Russell, Christopher T.; Leinweber, Hannes K.; Bromund, Kenneth R.; Le, Guan; Kepko, Lawrence; Anderson, Brian J.; Slavin, James A.; Baumjohann, Wolfgang

    2016-11-01

    The Magnetospheric Multiscale mission (MMS) targets the characterization of fine-scale current structures in the Earth's tail and magnetopause. The high speed of these structures, when traversing one of the MMS spacecraft, creates magnetic field signatures that cross the sensitive frequency bands of both search coil and fluxgate magnetometers. Higher data quality for analysis of these events can be achieved by combining data from both instrument types and using the frequency bands with best sensitivity and signal-to-noise ratio from both sensors. This can be achieved by a model-based frequency compensation approach which requires the precise knowledge of instrument gain and phase properties. We discuss relevant aspects of the instrument design and the ground calibration activities, describe the model development and explain the application on in-flight data. Finally, we show the precision of this method by comparison of in-flight data. It confirms unity gain and a time difference of less than 100 µs between the different magnetometer instruments.

  3. Preliminary feasibility analysis of a pressure modulator radiometer for remote sensing of tropospheric constituents

    NASA Technical Reports Server (NTRS)

    Orr, H. D., III; Rarig, P. L.

    1981-01-01

    A pressure modulator radiometer operated in a nadir viewing mode from the top of a midlatitude summer model of the atmosphere was theoretically studied for monitoring the mean volumetric mixing ratio of carbon monoxide in the troposphere. The mechanical characteristics of the instrument on the Nimbus 7 stratospheric and mesospheric sounder experiment are assumed and CO is assumed to be the only infrared active constituent. A line by line radiative transfer computer program is used to simulate the upwelling radiation reaching the top of the atmosphere. The performance of the instrument is examined as a function of the mean pressure in and the length of the instrument gas correlation cell. Instrument sensitivity is described in terms of signal to noise ratio for a 10 percent change in CO mixing ratio. Sensitivity to mixing ratio changes is also studied. It is concluded that tropospheric monitoring requires a pressure modulator drive having a larger swept volume and producing higher compression ratios at higher mean cell pressures than the Nimbus 7 design.

  4. Analysis instruments for the performance of Advanced Practice Nursing.

    PubMed

    Sevilla-Guerra, Sonia; Zabalegui, Adelaida

    2017-11-29

    Advanced Practice Nursing has been a reality in the international context for several decades and recently new nursing profiles have been developed in Spain as well that follow this model. The consolidation of these advanced practice roles has also led to of the creation of tools that attempt to define and evaluate their functions. This study aims to identify and explore the existing instruments that enable the domains of Advanced Practice Nursing to be defined. A review of existing international questionnaires and instruments was undertaken, including an analysis of the design process, the domains/dimensions defined, the main results and an exploration of clinimetric properties. Seven studies were analysed but not all proved to be valid, stable or reliable tools. One included tool was able to differentiate between the functions of the general nurse and the advanced practice nurse by the level of activities undertaken within the five domains described. These tools are necessary to evaluate the scope of advanced practice in new nursing roles that correspond to other international models of competencies and practice domains. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  5. Development of a disease-specific instrument to measure quality of life in patients with alopecia areata.

    PubMed

    Endo, Yuichiro; Miyachi, Yoshiki; Arakawa, Akiko

    2012-01-01

    Alopecia areata (AA) is a common hair loss disorder that frequently follows a chronic course. Although AA is apparently associated with disturbance of quality of life (QoL), no disease-specific instrument to measure the QoL has been developed. This study was conducted to develop a disease-specific self-administered instrument to measure AA patients' QoL (AAQ). A two-step cross-sectional study was conducted. Items were generated from qualitative interviews with five patients with AA (two men and three women, age 28±6.4 years). Then, a preliminary questionnaire was produced and delivered to the patients (n=122). The AAQ was examined in terms of statistical performance. The AAQ included 7 items in the following three subscales: 'restriction of activity', 'concealment' and 'adaptation'. The reliability of internal consistency was fair with Cronbach's alpha coefficients of 0.59-81 for each subscale. Confirmatory factor analysis and correlation analysis demonstrated that the AAQ had good construct validity. Interestingly, the AAQ was only correlated with subjective severity scores as rated by the patients, but not with objective disease severity assessed by investigators.

  6. The illusive sound of a Bundengan string

    NASA Astrophysics Data System (ADS)

    Parikesit, Gea O. F.; Kusumaningtyas, Indraswari

    2017-09-01

    The acoustics of a vibrating string is frequently used as a simple example of how physics can be applied in the field of art. In this paper we describe a simple experiment and analysis using a clipped string. This experiment can generate scientific curiosity among students because the sound generated by the string seem surprising to our senses. The first surprise comes from the gong-like sounds produced by the string, which we usually associate with metallic instruments rather than string instruments. The second surprise comes from the fact that when we shift the clip we perceive an increase of pitch, even though the measured value of the frequency with the maximum amplitude is actually decreased. We use high-speed video recording as well as audio spectral analysis to elucidate the physics behind these two surprises. A set of student activities is prepared to help them follow up their curiosity. Students can make their own clipped string, which is found in Indonesia in an instrument called Bundengan, by setting up their own prepared piano as invented by John Cage.

  7. Functional Status Assessment of COPD Based on Ability to Perform Daily Living Activities: A Systematic Review of Paper and Pencil Instruments.

    PubMed

    Monjazebi, Fateme; Dalvandi, Asghar; Ebadi, Abbas; Khankeh, Hamid Reza; Rahgozar, Mehdi; Richter, Jörg

    2015-08-06

    Activity of daily living (ADL) is an important predictor of mortality in patients with chronic obstructive pulmonary disease (COPD). Increasing ADL is important in patients with COPD and assessment of ADL is one of the best ways to evaluate the status of COPD patients. The objective of this systematic review was to provide an overview of the psychometric properties of paper and pencil instruments measuring ADL in patients with COPD. English papers published from 1980 to 2014 regarding ADL in patients with COPD were searched in  Web of Science, MEDLINE, Google Scholar, Cochrane, PubMed, ProQuest, and CINAHL databases using the following keywords: "COPD", "ADL", "activities of daily living", "daily activities", "instrument", "questionnaire", "paper-and-pencil instruments", and "measure". Following the Internet search, manual search was also done to find article references. A total of 186 articles were found. Of those, 31 met the inclusion criteria. Full texts of articles meeting the inclusion criteria were studied. Consensus-based standards for the selection of health measurement instruments"(COSMIN) were used to assess the quality of the studies. Data extraction form based on research aims developed by researchers and psychometric experts, with 17 questions was used. In these articles, 14 pen and paper instruments were identified for examining ADL in patients with COPD; of which, 4 dealt directly with ADL while 9 assessed other criteria i.e. dyspnea as ADL indicator. The majority of instruments only dealt with two main dimensions of ADL: Basic Activities of Daily Living (BADL) and Instrumental Activities of Daily Living (IADL), and did not consider Advanced Activities of Daily Living (AADL), which is influenced by cultural and motivational factors. Despite several ADL instruments identified, complete psychometric processes have only been done in a few of them. Selection of the appropriate instrument should focus on the aim of the study and the target construct.

  8. Reduced Gray Matter Volume Is Associated With Poorer Instrumental Activities of Daily Living Performance in Heart Failure.

    PubMed

    Alosco, Michael L; Brickman, Adam M; Spitznagel, Mary Beth; Narkhede, Atul; Griffith, Erica Y; Cohen, Ronald; Sweet, Lawrence H; Josephson, Richard; Hughes, Joel; Gunstad, John

    2016-01-01

    Heart failure patients require assistance with instrumental activities of daily living in part because of the high rates of cognitive impairment in this population. Structural brain insult (eg, reduced gray matter volume) is theorized to underlie cognitive dysfunction in heart failure, although no study has examined the association among gray matter, cognition, and instrumental activities of daily living in heart failure. The aim of this study was to investigate the associations among gray matter volume, cognitive function, and functional ability in heart failure. A total of 81 heart failure patients completed a cognitive test battery and the Lawton-Brody self-report questionnaire to assess instrumental activities of daily living. Participants underwent magnetic resonance imaging to quantify total gray matter and subcortical gray matter volume. Impairments in instrumental activities of daily living were common in this sample of HF patients. Regression analyses controlling for demographic and medical confounders showed that smaller total gray matter volume predicted decreased scores on the instrumental activities of daily living composite, with specific associations noted for medication management and independence in driving. Interaction analyses showed that reduced total gray matter volume interacted with worse attention/executive function and memory to negatively impact instrumental activities of daily living. Smaller gray matter volume is associated with greater impairment in instrumental activities of daily living in persons with heart failure, possibly via cognitive dysfunction. Prospective studies are needed to clarify the utility of clinical correlates of gray matter volume (eg, cognitive dysfunction) in identifying heart failure patients at risk for functional decline and determine whether interventions that target improved brain and cognitive function can preserve functional independence in this high-risk population.

  9. Data Analysis for the LISA Pathfinder Mission

    NASA Technical Reports Server (NTRS)

    Thorpe, James Ira

    2009-01-01

    The LTP (LISA Technology Package) is the core part of the Laser Interferometer Space Antenna (LISA) Pathfinder mission. The main goal of the mission is to study the sources of any disturbances that perturb the motion of the freely-falling test masses from their geodesic trajectories as well as 10 test various technologies needed for LISA. The LTP experiment is designed as a sequence of experimental runs in which the performance of the instrument is studied and characterized under different operating conditions. In order to best optimize subsequent experimental runs, each run must be promptly analysed to ensure that the following ones make best use of the available knowledge of the instrument ' In order to do this, all analyses must be designed and tested in advance of the mission and have sufficient built-in flexibility to account for unexpected results or behaviour. To support this activity, a robust and flexible data analysis software package is also required. This poster presents two of the main components that make up the data analysis effort: the data analysis software and the mock-data challenges used to validate analysis procedures and experiment designs.

  10. High Energy Astrophysics Program

    NASA Technical Reports Server (NTRS)

    1996-01-01

    This report reviews activities performed by members of the USRA (Universities Space Research Association) contract team during the six months during the reporting period (10/95 - 3/96) and projected activities during the coming six months. Activities take place at the Goddard Space Flight Center, within the Laboratory for High Energy Astrophysics. Developments concern instrumentation, observation, data analysis, and theoretical work in Astrophysics. Missions supported include: Advanced Satellite for Cosmology and Astrophysics (ASCA), X-ray Timing Experiment (XTE), X-ray Spectrometer (XRS), Astro-E, High Energy Astrophysics Science, Archive Research Center (HEASARC), and others.

  11. Moving your laboratories to the field – Advantages and limitations of the use of field portable instruments in environmental sample analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gałuszka, Agnieszka, E-mail: Agnieszka.Galuszka@ujk.edu.pl; Migaszewski, Zdzisław M.; Namieśnik, Jacek

    The recent rapid progress in technology of field portable instruments has increased their applications in environmental sample analysis. These instruments offer a possibility of cost-effective, non-destructive, real-time, direct, on-site measurements of a wide range of both inorganic and organic analytes in gaseous, liquid and solid samples. Some of them do not require the use of reagents and do not produce any analytical waste. All these features contribute to the greenness of field portable techniques. Several stationary analytical instruments have their portable versions. The most popular ones include: gas chromatographs with different detectors (mass spectrometer (MS), flame ionization detector, photoionization detector),more » ultraviolet–visible and near-infrared spectrophotometers, X-ray fluorescence spectrometers, ion mobility spectrometers, electronic noses and electronic tongues. The use of portable instruments in environmental sample analysis gives a possibility of on-site screening and a subsequent selection of samples for routine laboratory analyses. They are also very useful in situations that require an emergency response and for process monitoring applications. However, quantification of results is still problematic in many cases. The other disadvantages include: higher detection limits and lower sensitivity than these obtained in laboratory conditions, a strong influence of environmental factors on the instrument performance and a high possibility of sample contamination in the field. This paper reviews recent applications of field portable instruments in environmental sample analysis and discusses their analytical capabilities. - Highlights: • Field portable instruments are widely used in environmental sample analysis. • Field portable instruments are indispensable for analysis in emergency response. • Miniaturization of field portable instruments reduces resource consumption. • In situ analysis is in agreement with green analytical chemistry principles. • Performance requirements in field analysis stimulate technological progress.« less

  12. Radioactivity observed in scintillation counters during the HEAO-1 mission

    NASA Technical Reports Server (NTRS)

    Gruber, D. E.; Jung, G. V.; Matteson, J. L.

    1989-01-01

    Results are reported from an analysis of radioactivity induced in the NaI medium-energy detector of the hard X-ray and low-energy gamma-ray experiment during the HEAO-1 satellite mission (1977-1978). Consideration is given to the instrument characteristics, the origin and variability of background, and the separation of cosmic-ray activity from the internal activity due to South Atlantic Anomaly trapped protons. Energy spectra and tables listing the nuclide identifications are provided.

  13. [Construction and validation of a short scale of perception of barriers for the physical activity in adolescents].

    PubMed

    Cabanas-Sánchez, Verónica; Tejero-González, Carlos M; Veiga, Oscar L

    2012-01-01

    One of the main problems of health in the first world is the increase of physical inactivity. In this respect, adolescence has been identified as a critic period with high decline of physical activity. Therefore, a relevant line of research is the understanding of this social phenomenon. The aim of this study was to design a scale to assess perceived barriers to physical activity on adolescents. A convenience sample of 160 Spanish adolescents (84 girls), between 12 and 18 years old, was recruited for this study. Firstly, there were designed 40 items whose pertinence was evaluated through content validation by experts. Later, the participants were divided in two randomized groups, and Exploratory Factor Analysis and Confirmatory Factor Analysis were performed to define a short scale of 12 items. Cronbach Alfa Coefficent was used to evaluate internal consistence of the instrument. The scale reports four dimensions: incompatibility barriers (2 items), self-concept barriers (4 items), amotivation barriers (4 items) and social barriers (2 items). The scale showed enough construct validity (χ2=60.78; d.f.=48; p=0.100; GFI=0.88; CFI=0.94; RMSEA=0.58) and high internal reliability (α=0.80). Moreover, the scale was able to explain 67% of the data variance. The Short Scale of Perceived Barriers to Physical Activity in Adolescents is a valid and reliable instrument.

  14. Halo Coronal Mass Ejections during Solar Cycle 24: reconstruction of the global scenario and geoeffectiveness

    NASA Astrophysics Data System (ADS)

    Scolini, Camilla; Messerotti, Mauro; Poedts, Stefaan; Rodriguez, Luciano

    2018-02-01

    In this study we present a statistical analysis of 53 fast Earth-directed halo CMEs observed by the SOHO/LASCO instrument during the period Jan. 2009-Sep. 2015, and we use this CME sample to test the capabilities of a Sun-to-Earth prediction scheme for CME geoeffectiveness. First, we investigate the CME association with other solar activity features by means of multi-instrument observations of the solar magnetic and plasma properties. Second, using coronagraphic images to derive the CME kinematical properties at 0.1 AU, we propagate the events to 1 AU by means of the WSA-ENLIL+Cone model. Simulation results at Earth are compared with in-situ observations at L1. By applying the pressure balance condition at the magnetopause and a solar wind-Kp index coupling function, we estimate the expected magnetospheric compression and geomagnetic activity level, and compare them with global data records. The analysis indicates that 82% of the CMEs arrived at Earth in the next 4 days. Almost the totality of them compressed the magnetopause below geosynchronous orbits and triggered a geomagnetic storm. Complex sunspot-rich active regions associated with energetic flares result the most favourable configurations from which geoeffective CMEs originate. The analysis of related SEP events shows that 74% of the CMEs associated with major SEPs were geoeffective. Moreover, the SEP production is enhanced in the case of fast and interacting CMEs. In this work we present a first attempt at applying a Sun-to-Earth geoeffectiveness prediction scheme - based on 3D simulations and solar wind-geomagnetic activity coupling functions - to a statistical set of potentially geoeffective halo CMEs. The results of the prediction scheme are in good agreement with geomagnetic activity data records, although further studies performing a fine-tuning of such scheme are needed.

  15. Application of sodium carbonate prevents sulphur poisoning of catalysts in automated total mercury analysis

    NASA Astrophysics Data System (ADS)

    McLagan, David S.; Huang, Haiyong; Lei, Ying D.; Wania, Frank; Mitchell, Carl P. J.

    2017-07-01

    Analysis of high sulphur-containing samples for total mercury content using automated thermal decomposition, amalgamation, and atomic absorption spectroscopy instruments (USEPA Method 7473) leads to rapid and costly SO2 poisoning of catalysts. In an effort to overcome this issue, we tested whether the addition of powdered sodium carbonate (Na2CO3) to the catalyst and/or directly on top of sample material increases throughput of sulphur-impregnated (8-15 wt%) activated carbon samples per catalyst tube. Adding 5 g of Na2CO3 to the catalyst alone only marginally increases the functional lifetime of the catalyst (31 ± 4 g of activated carbon analyzed per catalyst tube) in relation to unaltered catalyst of the AMA254 total mercury analyzer (17 ± 4 g of activated carbon). Adding ≈ 0.2 g of Na2CO3 to samples substantially increases (81 ± 17 g of activated carbon) catalyst life over the unaltered catalyst. The greatest improvement is achieved by adding Na2CO3 to both catalyst and samples (200 ± 70 g of activated carbon), which significantly increases catalyst performance over all other treatments and enables an order of magnitude greater sample throughput than the unaltered samples and catalyst. It is likely that Na2CO3 efficiently sequesters SO2, even at high furnace temperatures to produce Na2SO4 and CO2, largely negating the poisonous impact of SO2 on the catalyst material. Increased corrosion of nickel sampling boats resulting from this methodological variation is easily resolved by substituting quartz boats. Overall, this variation enables an efficient and significantly more affordable means of employing automated atomic absorption spectrometry instruments for total mercury analysis of high-sulphur matrices.

  16. A new method for monitoring global volcanic activity. [Alaska, Hawaii, Washington, California, Iceland, Guatemala, El Salvador, and Nicaragua

    NASA Technical Reports Server (NTRS)

    Ward, P. L.; Endo, E.; Harlow, D. H.; Allen, R.; Eaton, J. P.

    1974-01-01

    The ERTS Data Collection System makes it feasible for the first time to monitor the level of activity at widely separated volcanoes and to relay these data rapidly to one central office for analysis. While prediction of specific eruptions is still an evasive goal, early warning of a reawakening of quiescent volcanoes is now a distinct possibility. A prototypical global volcano surveillance system was established under the ERTS program. Instruments were installed in cooperation with local scientists on 15 volcanoes in Alaska, Hawaii, Washington, California, Iceland, Guatemala, El Salvador and Nicaragua. The sensors include 19 seismic event counters that count four different sizes of earthquakes and six biaxial borehole tiltmeters that measure ground tilt with a resolution of 1 microradian. Only seismic and tilt data are collected because these have been shown in the past to indicate most reliably the level of volcano activity at many different volcanoes. Furthermore, these parameters can be measured relatively easily with new instrumentation.

  17. Development of automation software for neutron activation analysis process in Malaysian nuclear agency

    NASA Astrophysics Data System (ADS)

    Yussup, N.; Rahman, N. A. A.; Ibrahim, M. M.; Mokhtar, M.; Salim, N. A. A.; Soh@Shaari, S. C.; Azman, A.

    2017-01-01

    Neutron Activation Analysis (NAA) process has been established in Malaysian Nuclear Agency (Nuclear Malaysia) since 1980s. Most of the procedures established especially from sample registration to sample analysis are performed manually. These manual procedures carried out by the NAA laboratory personnel are time consuming and inefficient. Hence, a software to support the system automation is developed to provide an effective method to replace redundant manual data entries and produce faster sample analysis and calculation process. This paper describes the design and development of automation software for NAA process which consists of three sub-programs. The sub-programs are sample registration, hardware control and data acquisition; and sample analysis. The data flow and connection between the sub-programs will be explained. The software is developed by using National Instrument LabView development package.

  18. Astro-H/Hitomi data analysis, processing, and archive

    NASA Astrophysics Data System (ADS)

    Angelini, Lorella; Terada, Yukikatsu; Dutka, Michael; Eggen, Joseph; Harrus, Ilana; Hill, Robert S.; Krimm, Hans; Loewenstein, Michael; Miller, Eric D.; Nobukawa, Masayoshi; Rutkowski, Kristin; Sargent, Andrew; Sawada, Makoto; Takahashi, Hiromitsu; Yamaguchi, Hiroya; Yaqoob, Tahir; Witthoeft, Michael

    2018-01-01

    Astro-H is the x-ray/gamma-ray mission led by Japan with international participation, launched on February 17, 2016. Soon after launch, Astro-H was renamed Hitomi. The payload consists of four different instruments (SXS, SXI, HXI, and SGD) that operate simultaneously to cover the energy range from 0.3 keV up to 600 keV. On March 27, 2016, JAXA lost contact with the satellite and, on April 28, they announced the cessation of the efforts to restore mission operations. Hitomi collected about one month's worth of data with its instruments. This paper presents the analysis software and the data processing pipeline created to calibrate and analyze the Hitomi science data, along with the plan for the archive. These activities have been a collaborative effort shared between scientists and software engineers working in several institutes in Japan and United States.

  19. Socially supportive activity inventory: reliability and validity of a social activity instrument for long-term care institutions.

    PubMed

    Hsu, Ya-Chuan

    2011-09-01

    : Diverse social and recreational activities in elder care institutions have been provided to enrich a person's mental well-being amidst what is a relatively monotonous life. However, few instruments that measure the social activities of long-term care residents are available. : This study was designed to develop a culturally sensitive instrument (Socially Supportive Activity Inventory, SSAI) to assess quantity and quality of social activities for long-term care institutions and validate the instrument's psychometric properties. : The SSAI was developed on the basis of the social support theory, a synthesis of literature, and Taiwanese cultural mores. The instrument was rigorously subjected to a two-stage process to evaluate its reliability and validity. In Stage 1, six experts from diverse backgrounds were recruited to evaluate instrument items and estimate the content validity of the instrument using a content validity questionnaire. Items were modified and refined on the basis of the responses of the expert panel and a set of criteria. After obtaining approval from a university institutional review board, in the second stage of evaluating test-retest reliability, a convenience sample of 10 Taiwanese institutionalized elders in a pilot study, recruited from a nursing home, completed the revised instrument at two separate times over 2 weeks. : Results showed a content validity of .96. Test-retest reliability from a sample of 10 participants yielded stability coefficients of .76-1.00. The stability coefficient was 1.00 for the component of frequency, .76-1.00 for the component of meaningfulness, and .78-1.00 for the component of enjoyment. : The SSAI is a highly relevant and reliable culturally based instrument that can measure social activity in long-term care facilities. Because of the pilot nature of this study, future directions include further exploration of the SSAI instrument's psychometric properties. This should be done by enlarging the sample size to include more long-term care facilities and individual participants. Future studies can utilize diverse measures of social activity for comparison and validation of the SSAI.

  20. Industrial Instrument Mechanic. Occupational Analyses Series.

    ERIC Educational Resources Information Center

    Dean, Ann; Zagorac, Mike; Bumbaka, Nick

    This analysis covers tasks performed by an industrial instrument mechanic, an occupational title some provinces and territories of Canada have also identified as industrial instrumentation and instrument mechanic. A guide to analysis discusses development, structure, and validation method; scope of the occupation; trends; and safety. To facilitate…

  1. Reuse of disposable laparoscopic instruments: cost analysis*

    PubMed Central

    DesCôteaux, Jean-Gaston; Tye, Lucille; Poulin, Eric C.

    1996-01-01

    Objective To evaluate the cost benefits of reusing disposable laparoscopic instruments. Design A cost-analysis study based on a review of laparoscopic and thoracoscopic procedures performed between August 1990 and January 1994, including analysis of disposable instrument use, purchase records, and reprocessing costs for each instrument. Setting The general surgery department of a 461-bed teaching hospital where disposable laparoscopic instruments are routinely reused according to internally validated reprocessing protocols. Methods Laparoscopic and thoracoscopic interventions performed between August 1990 and January 1994 for which the number and types of disposable laparoscopic instruments were standardized. Main Outcome Measures Reprocessing cost per instrument, the savings realized by reusing disposable laparoscopic instruments and the cost-efficient number of reuses per instrument. Results The cost of reprocessing instruments varied from $2.64 (Can) to $4.66 for each disposable laparoscopic instrument. Purchases of 10 commonly reused disposable laparoscopic instruments totalled $183 279, and the total reprocessing cost was estimated at $35 665 for the study period. Not reusing disposable instruments would have cost $527 575 in instrument purchases for the same period. Disposable laparoscopic instruments were reused 1.7 to 68 times each. Conclusions Under carefully monitored conditions and strict guidelines, reuse of disposable laparoscopic and thoracoscopic instruments can be cost-effective. PMID:8769924

  2. Instrument Synthesis and Analysis Laboratory

    NASA Technical Reports Server (NTRS)

    Wood, H. John

    2004-01-01

    The topics addressed in this viewgraph presentation include information on 1) Historic instruments at Goddard; 2) Integrated Design Capability at Goddard; 3) The Instrument Synthesis and Analysis Laboratory (ISAL).

  3. Experimental active and passive dosimetry systems for the NASA Skylab program

    NASA Technical Reports Server (NTRS)

    Schneider, M. F.; Janni, J. F.; Ainsworth, G. C.

    1972-01-01

    Active and passive dosimetry instrumentation to measure absorbed dose, charged particle spectra, and linear energy transfer spectra inside the command module and orbital workshop on the Skylab program were developed and tested. The active dosimetry system consists of one integral unit employing both a tissue equivalent ionization chamber and silicon solid state detectors. The instrument measures dose rates from 0.2 millirad/hour to 25 rads/hour, linear energy transfer spectra from 2.8 to 42.4 Kev/micron, and the proton and alpha particle energy spectra from 0.5 to 75 Mev. The active dosimeter is equipped with a portable radiation sensor for use in astronaut on-body and spacecraft shielding surveys during passage of the Skylab through significant space radiations. Data are transmitted in real time or are recorded by onboard spacecraft tape recorder for rapid evaluation of the radiation levels. The passive dosimetry systems consist of twelve (12) hard-mounted assemblies, each containing a variety of passive radiation sensors which are recoverable at the end of the mission for analysis.

  4. Power calculator for instrumental variable analysis in pharmacoepidemiology

    PubMed Central

    Walker, Venexia M; Davies, Neil M; Windmeijer, Frank; Burgess, Stephen; Martin, Richard M

    2017-01-01

    Abstract Background Instrumental variable analysis, for example with physicians’ prescribing preferences as an instrument for medications issued in primary care, is an increasingly popular method in the field of pharmacoepidemiology. Existing power calculators for studies using instrumental variable analysis, such as Mendelian randomization power calculators, do not allow for the structure of research questions in this field. This is because the analysis in pharmacoepidemiology will typically have stronger instruments and detect larger causal effects than in other fields. Consequently, there is a need for dedicated power calculators for pharmacoepidemiological research. Methods and Results The formula for calculating the power of a study using instrumental variable analysis in the context of pharmacoepidemiology is derived before being validated by a simulation study. The formula is applicable for studies using a single binary instrument to analyse the causal effect of a binary exposure on a continuous outcome. An online calculator, as well as packages in both R and Stata, are provided for the implementation of the formula by others. Conclusions The statistical power of instrumental variable analysis in pharmacoepidemiological studies to detect a clinically meaningful treatment effect is an important consideration. Research questions in this field have distinct structures that must be accounted for when calculating power. The formula presented differs from existing instrumental variable power formulae due to its parametrization, which is designed specifically for ease of use by pharmacoepidemiologists. PMID:28575313

  5. Improvement of analytical capabilities of neutron activation analysis laboratory at the Colombian Geological Survey

    NASA Astrophysics Data System (ADS)

    Parrado, G.; Cañón, Y.; Peña, M.; Sierra, O.; Porras, A.; Alonso, D.; Herrera, D. C.; Orozco, J.

    2016-07-01

    The Neutron Activation Analysis (NAA) laboratory at the Colombian Geological Survey has developed a technique for multi-elemental analysis of soil and plant matrices, based on Instrumental Neutron Activation Analysis (INAA) using the comparator method. In order to evaluate the analytical capabilities of the technique, the laboratory has been participating in inter-comparison tests organized by Wepal (Wageningen Evaluating Programs for Analytical Laboratories). In this work, the experimental procedure and results for the multi-elemental analysis of four soil and four plant samples during participation in the first round on 2015 of Wepal proficiency test are presented. Only elements with radioactive isotopes with medium and long half-lives have been evaluated, 15 elements for soils (As, Ce, Co, Cr, Cs, Fe, K, La, Na, Rb, Sb, Sc, Th, U and Zn) and 7 elements for plants (Br, Co, Cr, Fe, K, Na and Zn). The performance assessment by Wepal based on Z-score distributions showed that most results obtained |Z-scores| ≤ 3.

  6. Operational CryoSat Product Quality Assessment

    NASA Astrophysics Data System (ADS)

    Mannan, Rubinder; Webb, Erica; Hall, Amanda; Bouzinac, Catherine

    2013-12-01

    The performance and quality of the CryoSat data products are routinely assessed by the Instrument Data quality Evaluation and Analysis Service (IDEAS). This information is then conveyed to the scientific and user community in order to allow them to utilise CryoSat data with confidence. This paper presents details of the Quality Control (QC) activities performed for CryoSat products under the IDEAS contract. Details of the different QC procedures and tools deployed by IDEAS to assess the quality of operational data are presented. The latest updates to the Instrument Processing Facility (IPF) for the Fast Delivery Marine (FDM) products and the future update to Baseline-C are discussed.

  7. Oceanography from space

    NASA Technical Reports Server (NTRS)

    Stewart, R. H.

    1982-01-01

    Active and passive spaceborne instruments that can observe the sea are discussed. Attention is given to satellite observations of ocean surface temperature and heating, wind speed and direction, ocean currents, wave height, ocean color, and sea ice. Specific measurements now being made from space are described, the accuracy of various instruments is considered, and problems associated with the analysis of satellite data are examined. It is concluded that the satellites and techniques used by different nations should be sufficiently standard that data from one satellite can be directly compared with data from another and that accurate calibration and overlap of satellite data are necessary to confirm the continuity and homogeneity of the data.

  8. Statistical analysis of tiny SXR flares observed by SphinX

    NASA Astrophysics Data System (ADS)

    Gryciuk, Magdalena; Siarkowski, Marek; Sylwester, Janusz; Kepa, Anna; Gburek, Szymon; Mrozek, Tomasz; Podgórski, Piotr

    2015-08-01

    The Solar Photometer in X-rays (SphinX) was designed to observe soft X-ray solar emission in the energy range between ~1 keV and 15 keV with the resolution better than 0.5 keV. The instrument operated from February until November 2009 aboard CORONAS-Photon satellite, during the phase of exceptionally low minimum of solar activity. Here we use SphinX data for analysis of micro-flares and brightenings. Despite a very low activity more than a thousand small X-ray events have been recognized by semi-automatic inspection of SphinX light curves. A catalogue of temporal and physical characteristics of these events is shown and discussed and results of the statistical analysis of the catalogue data are presented.

  9. Determination of element composition and extraterrestrial material occurrence in moss and lichen samples from King George Island (Antarctica) using reactor neutron activation analysis and SEM microscopy.

    PubMed

    Mróz, Tomasz; Szufa, Katarzyna; Frontasyeva, Marina V; Tselmovich, Vladimir; Ostrovnaya, Tatiana; Kornaś, Andrzej; Olech, Maria A; Mietelski, Jerzy W; Brudecki, Kamil

    2018-01-01

    Seven lichens (Usnea antarctica and U. aurantiacoatra) and nine moss samples (Sanionia uncinata) collected in King George Island were analyzed using instrumental neutron activation analysis, and concentration of major and trace elements was calculated. For some elements, the concentrations observed in moss samples were higher than corresponding values reported from other sites in the Antarctica, but in the lichens, these were in the same range of concentrations. Scanning electron microscopy (SEM) and statistical analysis showed large influence of volcanic-origin particles. Also, the interplanetary cosmic particles (ICP) were observed in investigated samples, as mosses and lichens are good collectors of ICP and micrometeorites.

  10. ADCS Prevention Instrument Project: assessment of instrumental activities of daily living for community-dwelling elderly individuals in dementia prevention clinical trials.

    PubMed

    Galasko, Douglas; Bennett, David A; Sano, Mary; Marson, Daniel; Kaye, Jeff; Edland, Steven D

    2006-01-01

    In primary prevention trials for Alzheimer disease, the inception cohort typically has normal or minimally impaired complex activities of daily living (ADL). ADL change during a trial could trigger detailed evaluation or serve as an outcome measure. A brief, easily administered, and reliable ADL rating scale would assist prevention studies. To develop an ADL scale for prevention trials that allows self-rating or completion by informants. The Activities of Daily Living-Prevention Instrument (ADL-PI) was developed, comprising 15 ADL and 5 physical function questions. Six hundred forty-four elderly subjects participating in the Prevention Instrument Project completed a self-rated version of the ADL-PI, and informants for 632 subjects completed an informant version. Informants also completed a Mild Cognitive Impairment (MCI) ADL questionnaire to allow comparisons. Subjects performed well on all ADL scales at baseline. Completion of the ADL-PI questionnaires at home or in-clinic yielded comparable information. Scores from baseline to 3 months had good reliability. The ADL-PI, obtained from either self-report or informants, discriminated between subjects rated as CDR 0 and CDR 0.5. Subjects with worse baseline cognitive performance also had slightly worse ADL-PI scores. Preliminary analysis indicates that subjects who triggered cognitive evaluations had slightly lower baseline ADL-PI scores by both self and informant reports. The ADL-PI can be completed at home or in clinic, and has adequate reliability. The utility of self-administered and informant versions and predictive value of reported deficits requires further follow-up.

  11. Fluid Mechanics Experiments as a Unifying Theme in the Physics Instrumentation Laboratory Course

    NASA Astrophysics Data System (ADS)

    Borrero-Echeverry, Daniel

    2017-11-01

    We discuss the transformation of a junior-level instrumentation laboratory course from a sequence of cookbook lab exercises to a semester-long, project-based course. In the original course, students conducted a series of activities covering the usual electronics topics (amplifiers, filters, oscillators, logic gates, etc.) and learned basic LabVIEW programming for data acquisition and analysis. Students complained that these topics seemed disconnected and not immediately applicable to ``real'' laboratory work. To provide a unifying theme, we restructured the course around the design, construction, instrumentation of a low-cost Taylor-Couette cell where fluid is sheared between rotating coaxial cylinders. The electronics labs were reworked to guide students from fundamental electronics through the design and construction of a stepper motor driver, which was used to actuate the cylinders. Some of the legacy labs were replaced with a module on computer-aided design (CAD) in which students designed parts for the apparatus, which they then built in the departmental machine shop. Signal processing topics like spectral analysis were introduced in the context of time-series analysis of video data acquired from flow visualization. The course culminated with a capstone project in which students conducted experiments of their own design on a variety of topics in rheology and nonlinear dynamics.

  12. GFZ Wireless Seismic Array (GFZ-WISE), a Wireless Mesh Network of Seismic Sensors: New Perspectives for Seismic Noise Array Investigations and Site Monitoring

    PubMed Central

    Picozzi, Matteo; Milkereit, Claus; Parolai, Stefano; Jaeckel, Karl-Heinz; Veit, Ingo; Fischer, Joachim; Zschau, Jochen

    2010-01-01

    Over the last few years, the analysis of seismic noise recorded by two dimensional arrays has been confirmed to be capable of deriving the subsoil shear-wave velocity structure down to several hundred meters depth. In fact, using just a few minutes of seismic noise recordings and combining this with the well known horizontal-to-vertical method, it has also been shown that it is possible to investigate the average one dimensional velocity structure below an array of stations in urban areas with a sufficient resolution to depths that would be prohibitive with active source array surveys, while in addition reducing the number of boreholes required to be drilled for site-effect analysis. However, the high cost of standard seismological instrumentation limits the number of sensors generally available for two-dimensional array measurements (i.e., of the order of 10), limiting the resolution in the estimated shear-wave velocity profiles. Therefore, new themes in site-effect estimation research by two-dimensional arrays involve the development and application of low-cost instrumentation, which potentially allows the performance of dense-array measurements, and the development of dedicated signal-analysis procedures for rapid and robust estimation of shear-wave velocity profiles. In this work, we present novel low-cost wireless instrumentation for dense two-dimensional ambient seismic noise array measurements that allows the real–time analysis of the surface-wavefield and the rapid estimation of the local shear-wave velocity structure for site response studies. We first introduce the general philosophy of the new system, as well as the hardware and software that forms the novel instrument, which we have tested in laboratory and field studies. PMID:22319298

  13. Validation of the Dementia Care Assessment Packet-Instrumental Activities of Daily Living

    PubMed Central

    Lee, Seok Bum; Park, Jeong Ran; Yoo, Jeong-Hwa; Park, Joon Hyuk; Lee, Jung Jae; Yoon, Jong Chul; Jhoo, Jin Hyeong; Lee, Dong Young; Woo, Jong Inn; Han, Ji Won; Huh, Yoonseok; Kim, Tae Hui

    2013-01-01

    Objective We aimed to evaluate the psychometric properties of the IADL measure included in the Dementia Care Assessment Packet (DCAP-IADL) in dementia patients. Methods The study involved 112 dementia patients and 546 controls. The DCAP-IADL was scored in two ways: observed score (OS) and predicted score (PS). The reliability of the DCAP-IADL was evaluated by testing its internal consistency, inter-rater reliability and test-retest reliability. Discriminant validity was evaluated by comparing the mean OS and PS between dementia patients and controls by ANCOVA. Pearson or Spearman correlation analysis was performed with other instruments to assess concurrent validity. Receiver operating characteristics curve analysis was performed to examine diagnostic accuracy. Results Chronbach's α coefficients of the DCAP-IADL were above 0.7. The values in dementia patients were much higher (OS=0.917, PS=0.927), indicating excellent degrees of internal consistency. Inter-rater reliabilities and test-retest reliabilities were statistically significant (p<0.05). PS exhibited higher reliabilities than OS. The mean OS and PS of dementia patients were significantly higher than those of the non-demented group after controlling for age, sex and education level. The DCAP-IADL was significantly correlated with other IADL instruments and MMSE-KC (p<0.001). Areas under the curves of the DCAP-IADL were above 0.9. Conclusion The DCAP-IADL is a reliable and valid instrument for evaluating instrumental ability of daily living for the elderly, and may also be useful for screening dementia. Moreover, administering PS may enable the DCAP-IADL to overcome the differences in gender, culture and life style that hinders accurate evaluation of the elderly in previous IADL instruments. PMID:24302946

  14. Medial Amygdala Lesions Selectively Block Aversive Pavlovian–Instrumental Transfer in Rats

    PubMed Central

    McCue, Margaret G.; LeDoux, Joseph E.; Cain, Christopher K.

    2014-01-01

    Pavlovian conditioned stimuli (CSs) play an important role in the reinforcement and motivation of instrumental active avoidance (AA). Conditioned threats can also invigorate ongoing AA responding [aversive Pavlovian–instrumental transfer (PIT)]. The neural circuits mediating AA are poorly understood, although lesion studies suggest that lateral, basal, and central amygdala nuclei, as well as infralimbic prefrontal cortex, make key, and sometimes opposing, contributions. We recently completed an extensive analysis of brain c-Fos expression in good vs. poor avoiders following an AA test (Martinez et al., 2013, Learning and Memory). This analysis identified medial amygdala (MeA) as a potentially important region for Pavlovian motivation of instrumental actions. MeA is known to mediate defensive responding to innate threats as well as social behaviors, but its role in mediating aversive Pavlovian–instrumental interactions is unknown. We evaluated the effect of MeA lesions on Pavlovian conditioning, Sidman two-way AA conditioning (shuttling) and aversive PIT in rats. Mild footshocks served as the unconditioned stimulus in all conditioning phases. MeA lesions had no effect on AA but blocked the expression of aversive PIT and 22 kHz ultrasonic vocalizations in the AA context. Interestingly, MeA lesions failed to affect Pavlovian freezing to discrete threats but reduced freezing to contextual threats when assessed outside of the AA chamber. These findings differentiate MeA from lateral and central amygdala, as lesions of these nuclei disrupt Pavlovian freezing and aversive PIT, but have opposite effects on AA performance. Taken together, these results suggest that MeA plays a selective role in the motivation of instrumental avoidance by general or uncertain Pavlovian threats. PMID:25278858

  15. Assessing collaborative computing: development of the Collaborative-Computing Observation Instrument (C-COI)

    NASA Astrophysics Data System (ADS)

    Israel, Maya; Wherfel, Quentin M.; Shehab, Saadeddine; Ramos, Evan A.; Metzger, Adam; Reese, George C.

    2016-07-01

    This paper describes the development, validation, and uses of the Collaborative Computing Observation Instrument (C-COI), a web-based analysis instrument that classifies individual and/or collaborative behaviors of students during computing problem-solving (e.g. coding, programming). The C-COI analyzes data gathered through video and audio screen recording software that captures students' computer screens as they program, and their conversations with their peers or adults. The instrument allows researchers to organize and quantify these data to track behavioral patterns that could be further analyzed for deeper understanding of persistence and/or collaborative interactions. The article provides a rationale for the C-COI including the development of a theoretical framework for measuring collaborative interactions in computer-mediated environments. This theoretical framework relied on the computer-supported collaborative learning literature related to adaptive help seeking, the joint problem-solving space in which collaborative computing occurs, and conversations related to outcomes and products of computational activities. Instrument development and validation also included ongoing advisory board feedback from experts in computer science, collaborative learning, and K-12 computing as well as classroom observations to test out the constructs in the C-COI. These processes resulted in an instrument with rigorous validation procedures and a high inter-rater reliability.

  16. A study of electro-mechanical and infrastructure instrumentation facilities in environmental laboratory.

    PubMed

    Dhawangale, R M; Kawale, S M; Waghmare, Maya; Pandya, G H; Kondawar, V K

    2006-01-01

    Environmental laboratories carry out measurement and analysis of a number of physical, chemical and biological parameters. Each parameter requires some sort of instrument for its determination. Providing efficient instrumentation services to various departments of the Institute is an stupendous task. Instrumentation services in the form of installation, operation, repair and maintenanace of electro-mechanical equipment requires an in-depth experience and knowledge of the working, fabrication, design and repair of similar type of instruments so that the need of space, installation pre-requisites, budget constraints, availability of essential spares parts could be assessed. The paper discusses the operation of an environmental instrument repairs and maintenance, and audio-visual facilities. Suggestions for drafting of the proper specifications for procurement of laboratory equipments, such as ovens, furnaces, refrigerators, blowers, audio visual aids, and spares and accessories are given in this paper. The paper also gives the detailed information on various aspects that are needed for checking and testing of the equipment against specification before putting it in operational use. Development of a preventive maintenance program involving QC checks and keeping an inventory of essential spares required are also discussed in this paper. It is felt that such services are essential in providing smooth support to carry out research and development activities of the Institute.

  17. The relationship among multiple patient-reported outcomes measures for patients with ulcerative colitis receiving treatment with MMX ® formulated delayed-release mesalamine.

    PubMed

    Yarlas, Aaron; Yen, Linnette; Hodgkins, Paul

    2015-03-01

    Ulcerative colitis (UC) is associated with impaired health-related quality of life (HRQL) and work-related outcomes (WRO). This analysis examined correspondences among measures of HRQL and WRO in patients with UC, as well as the magnitude of each measure's responsiveness to disease activity and treatment. An open-label, prospective trial of delayed-release mesalamine tablets formulated with MMX(®) technology included 8 weeks of treatment for patients with active mild-to-moderate UC (n = 137) and 12 months of maintenance treatment for patients with quiescent UC (n = 206). Spearman correlations (ρ) measured inter-domain associations across measures of generic HRQL [12-item Short-Form Health Survey (SF-12v2)], disease-specific HRQL [Short Inflammatory Bowel Disease Questionnaire (SIBDQ)], and disease-specific WRO [Work Productivity and Activity Impairment for Specific Health Problems (WPAI:SHP)]. Responsiveness to disease activity and treatment was assessed for each instrument. Changes in scores from baseline to week 8 were moderately correlated across all instrument domains: 65 of 80 (81 %) between-instrument inter-domain correlations were of moderate magnitude (0.30 < ρ < 0.70), with an average magnitude of 0.42 [95 % confidence interval (CI) 0.38-0.46]. Associations between symptom measures were stronger for SIBDQ (|average ρ| = 0.41; 95 % CI 0.34-0.48) and WPAI:SHP (0.40; 0.30-0.47) than SF-12v2 (0.30; 0.27-0.34). SIBDQ was most sensitive to treatment [effect size (d z ) for change from baseline to week 8 = 0.62; 95 % CI 0.35-0.89], followed by WPAI:SHP (d z = 0.43; 0.32-0.54) and SF-12v2 (d z = 0.33; 0.27-0.39). While the SIBDQ showed the greatest overall responsiveness to disease activity and treatment, all three patient-reported outcomes instruments provided complementary interpretive information regarding the impact of UC treatment.

  18. Lessons Learned From the Analysis of the SAFOD Downhole Instrument Package.

    NASA Astrophysics Data System (ADS)

    Johnson, Wade; Mencin, David; Mattioli, Glen

    2013-04-01

    In September of 2008 a downhole instrument package (DIP) consisting of a string of seismometers and tilt meters in isolated pressure vessels (PODs) was installed in the SAFOD main borehole. This package was designed to protect the sensors from the corrosive borehole environment and to operate for two years. The SAFOD borehole is not sealed at the bottom allowing borehole gasses and fluids infiltratration. Previous short-term installations of instruments in the SAFOD main borehole had also failed as a result of corrosion of the wireline cable head. The average failure time for these installations was two weeks. The use of stainless steel tubing connected to the pressure vessels through gas tight fittings was designed to block borehole fluid and gas infiltration of the individual instruments within the PODs. Unfortunately, the DIP completely failed within a month of its installation. In October of 2010, the DIP was removed from the borehole and a failure analysis was performed. This analysis involved to following steps: 1. Analysis of data to understand timeline of failure 2. Remove instrument safely, maintaining integrity of spliced section and documenting any external clues. Test instrument at surface 3. Open PODs in a way that allows for sampling and avoids damaging instruments. 4. Chemical analysis of fluids recovered from splices and PODs. 5. Instrument failure analysis by the instrument manufacturers. The analysis found that there were several design flaws in the DIP. This included the use of motor oil to take up air space in the individual PODs, use of a large number of gas tight seals, lack of internal seals, poorly done solder joints, use of non-temperature rated sensors, and lack of management oversight. The lessons learned from the attempts to instrument the SAFOD borehole are critical to the success of future deep borehole projects.

  19. Exploring PCK ability of prospective science teachers in reflective learning on heat and transfer

    NASA Astrophysics Data System (ADS)

    Nurmatin, S.; Rustaman, N. Y.

    2016-02-01

    Learning can be planned by the person him/herself when he or she tries to reflect his/her learning. A study involving prospective science teachers in junior secondary schools was carried out to analyze their ability on Pedagogical Content Knowledge (PCK) in reflective learning after teaching practice. The study was focused especially in creating Pedagogical and Professional Repertoires (PaP-eRs) as part of resource-folios. PaP-eRs as a narrative writing in the learning activities are created by prospective science teachers after lesson plan implementation. Making the narrative writing is intended that prospective science teachers can reflect their learning in teaching. Research subjects are six prospective science teachers who are implementing "Program Pengalaman Lapangan" (PPL) in two junior secondary schools in Bandung, West Java, Indonesia. All of them were assigned by supervisor teachers to teach VII grade students on certain topic "heat and its transfer". Instruments used as a means of collecting data in this study is PaP-eRs. Collected PaP-eRs were then analyzed using PaP-eRs analysis format as instruments for analysis. The result of analyzing PaP-eRs indicates that learning activities, which narrated, involve initial activities, core activities and final activities. However, any activity, which is narrated just superficial as its big line so the narration cannot be, used as reflective learning. It indicates that PCK ability of prospective science teachers in creating narrative writing (PaP-eRs) for reflective learning is still low.

  20. Is food-related lifestyle (FRL) able to reveal food consumption patterns in non-Western cultural environments? Its adaptation and application in urban China.

    PubMed

    Grunert, Klaus G; Perrea, Toula; Zhou, Yanfeng; Huang, Guang; Sørensen, Bjarne T; Krystallis, Athanasios

    2011-04-01

    Research related to food-related behaviour in China is still scarce, one reason being the fact that food consumption patterns in East Asia do not appear to be easily analyzed by models originating in Western cultures. The objective of the present work is to examine the ability of the food related lifestyle (FRL) instrument to reveal food consumption patterns in a Chinese context. Data were collected from 479 respondents in 6 major Chinese cities using a Chinese version of the FRL instrument. Analysis of reliability and dimensionality of the scales resulted in a revised version of the instrument, in which a number of dimensions of the original instrument had to be omitted. This revised instrument was tested for statistical robustness and used as a basis for the derivation of consumer segments. Construct validity of the instrument was then investigated by profiling the segments in terms of consumer values, attitudes and purchase behaviour, using frequency of consumption of pork products as an example. Three consumer segments were identified: concerned, uninvolved and traditional. This pattern replicates partly those identified in Western cultures. Moreover, all three segments showed consistent value-attitude-behaviour profiles. The results also suggest which dimensions may be missing in the instrument in a more comprehensive instrument adapted to Chinese conditions, most notably a broader treatment of eating out activities. Copyright © 2010 Elsevier Ltd. All rights reserved.

  1. COMET: a planned airborne mission to simultaneously measure CO2 and CH4 columns using airborne remote sensing and in-situ techniques

    NASA Astrophysics Data System (ADS)

    Fix, A.; Amediek, A.; Büdenbender, C.; Ehret, G.; Wirth, M.; Quatrevalet, M.; Rapp, M.; Gerilowski, K.; Bovensmann, H.; Gerbig, C.; Pfeilsticker, K.; Zöger, M.; Giez, A.

    2013-12-01

    To better predict future trends in the cycles of the most important anthropogenic greenhouse gases, CO2 and CH4, there is a need to measure and understand their distribution and variation on various scales. To address these requirements it is envisaged to deploy a suite of state-of-the-art airborne instruments that will be capable to simultaneously measure the column averaged dry-air mixing ratios (XGHG) of both greenhouse gases along the flight path. As the measurement platform serves the research aircraft HALO, a modified Gulfstream G550, operated by DLR. This activity is dubbed CoMet (CO2 and Methane Mission). The instrument package of CoMet will consist of active and passive remote sensors as well as in-situ instruments to complement the column measurements by highly-resolved profile information. As an active remote sensing instrument CHARM-F, the integrated-path differential absorption lidar currently under development at DLR, will provide both, XCO2 and XCH4, below flight altitude. The lidar instrument will be complemented by MAMAP which is a NIR/SWIR absorption spectrometer developed by University of Bremen and which is also capable to derive XCH4 and XCO2. As an additional passive instrument, mini-DOAS operated by University of Heidelberg will contribute with additional context information about the investigated air masses. In order to compare the remote sensing instruments with integrated profile information, in-situ instrumentation is indispensable. The in-situ package will therefore comprise wavelength-scanned Cavity-Ring-Down Spectroscopy (CRDS) for the detection of CO2, CH4, CO and H2O and a flask sampler for collection of atmospheric samples and subsequent laboratory analysis. Furthermore, the BAsic HALO Measurement And Sensor System (BAHAMAS) will provide an accurate set of meteorological and aircraft state parameters for each scientific flight. Within the frame of the first CoMet mission scheduled for the 2015 timeframe it is planned to concentrate on small to sub-continental scale variations of the greenhouse gases. This does not only allow to identify local emission sources of GHGs, but also opens up the opportunity to use important remote sensing and in-situ data information for the inverse modeling approach for regional budgeting. CoMet is also targeting at providing a validation platform of future spaceborne GHG missions in particular the upcoming French-German methane mission MERLIN. CHARM-F was devised as an airborne demonstrator for MERLIN, and, as such will be a key instrument for MERLIN validation.

  2. Occupational Education Program, Image of the World of Work. Description and Analysis of Teacher Orientation Activities (August 1968).

    ERIC Educational Resources Information Center

    Colorado State Univ., Ft. Collins. Human Factors Research Lab.

    A project was conducted to determine the relationship between changes in attitudes toward work of seventh grade pupils and specified instructional practices of their social studies or language arts teachers. The study encompassed: (1) developing and administering instruments to students and instructors to asess attitudes toward work, (2)…

  3. An Analysis of Educational Outreach by Ohio Theatres.

    ERIC Educational Resources Information Center

    Leptak, Jeffrey; Heimlich, Joe E.

    A descriptive research study of the educational outreach activities conducted by Ohio theatres used a mail questionnaire to survey the 36 professional and large community theatres within the state. Thirty responded, for a response rate of 83.3 percent. For each theatre, the instrument sought information on the kind of theatre, the number of staff,…

  4. Assembly of a Modular Fluorimeter and Associated Software: Using LabVIEW in an Advanced Undergraduate Analytical Chemistry Laboratory

    ERIC Educational Resources Information Center

    Algar, W. Russ; Massey, Melissa; Krull, Ulrich J.

    2009-01-01

    A laboratory activity for an upper-level undergraduate course in instrumental analysis has been created around LabVIEW. Students learn rudimentary programming and interfacing skills during the construction of a fluorimeter assembled from common modular components. The fluorimeter consists of an inexpensive data acquisition module, LED light…

  5. Simultaneous Determination of Caffeine and Vitamin B6 in Energy Drinks by High-Performance Liquid Chromatography (HPLC)

    ERIC Educational Resources Information Center

    Leacock, Rachel E.; Stankus, John J.; Davis, Julian M.

    2011-01-01

    A high-performance liquid chromatography experiment to determine the concentration of caffeine and vitamin B6 in sports energy drinks has been developed. This laboratory activity, which is appropriate for an upper-level instrumental analysis course, illustrates the standard addition method and simultaneous determination of two species. (Contains 1…

  6. Stratigraphy and geochemistry of the Stone mountain core (64001/2)

    NASA Astrophysics Data System (ADS)

    Korotev, R. L.; Morris, R. V.; Lauer, H. V.

    1984-11-01

    Ferromagnetic resonance and magnetic data measured on both sections of the double drive tube cord 64001/2 collected on Stone mountain, station four, Apollo 16 are reported, along with instrumental neutron activation analysis data measured on the lower section. These data provide insight into the depositional and irradiational history and the geochemical provenances of the core.

  7. Stratigraphy and geochemistry of the Stone mountain core (64001/2)

    NASA Technical Reports Server (NTRS)

    Korotev, R. L.; Morris, R. V.; Lauer, H. V., Jr.

    1984-01-01

    Ferromagnetic resonance and magnetic data measured on both sections of the double drive tube cord 64001/2 collected on Stone mountain, station four, Apollo 16 are reported, along with instrumental neutron activation analysis data measured on the lower section. These data provide insight into the depositional and irradiational history and the geochemical provenances of the core.

  8. The Relationship between Music Participation and Mathematics Achievement in Middle School Students

    ERIC Educational Resources Information Center

    Boyd, Joshua Robert

    2013-01-01

    A comparative analysis was used to study the results from a descriptive survey of selected middle school students in Grades 6, 7, and 8. Student responses to the survey tool was used to compare multiple variables of music participation and duration of various musical activities, such as singing and performing on instruments, to the mathematics…

  9. Qualitative analysis of the contributions of nutritionists to the development of an online instrument for monitoring the food intake of schoolchildren

    USDA-ARS?s Scientific Manuscript database

    The Consumo Alimentar e Atividade Fisica de Escolares (CAAFE) questionnaire is an online research tool that has been developed to enable the self-report of physical activity and diet by Brazilian schoolchildren aged 7–10 years. Formative research was conducted with nutritionists during the developme...

  10. Generational Differences among Community College Students in Their Evaluation of Academic Cheating

    ERIC Educational Resources Information Center

    Wotring, Kathleen E.; Bol, Linda

    2011-01-01

    This study examined how community college students (n = 650) vary by generation and other characteristics in their evaluation of academic activities as cheating. A Likert-type instrument was developed based on the literature, pilot tested, and subjected to factor analysis. Results of MANOVA found no difference by generation in the evaluation of…

  11. Determination of accurate vertical atmospheric profiles of extinction and turbulence

    NASA Astrophysics Data System (ADS)

    Hammel, Steve; Campbell, James; Hallenborg, Eric

    2017-09-01

    Our ability to generate an accurate vertical profile characterizing the atmosphere from the surface to a point above the boundary layer top is quite rudimentary. The region from a land or sea surface to an altitude of 3000 meters is dynamic and particularly important to the performance of many active optical systems. Accurate and agile instruments are necessary to provide measurements in various conditions, and models are needed to provide the framework and predictive capability necessary for system design and optimization. We introduce some of the path characterization instruments and describe the first work to calibrate and validate them. Along with a verification of measurement accuracy, the tests must also establish each instruments performance envelope. Measurement of these profiles in the field is a problem, and we will present a discussion of recent field test activity to address this issue. The Comprehensive Atmospheric Boundary Layer Extinction/Turbulence Resolution Analysis eXperiment (CABLE/TRAX) was conducted late June 2017. There were two distinct objectives for the experiment: 1) a comparison test of various scintillometers and transmissometers on a homogeneous horizontal path; 2) a vertical profile experiment. In this paper we discuss only the vertical profiling effort, and we describe the instruments that generated data for vertical profiles of absorption, scattering, and turbulence. These three profiles are the core requirements for an accurate assessment of laser beam propagation.

  12. The role of MEXART in the National Space Weather Laboratory of Mexico: Detection of solar wind, CMEs, ionosphere, active regions and flares.

    NASA Astrophysics Data System (ADS)

    Mejia-Ambriz, J.; Gonzalez-Esparza, A.; De la Luz, V.; Villanueva-Hernandez, P.; Andrade, E.; Aguilar-Rodriguez, E.; Chang, O.; Romero Hernandez, E.; Sergeeva, M. A.; Perez Alanis, C. A.; Reyes-Marin, P. A.

    2017-12-01

    The National Space Weather Laboratory - Laboratorio Nacional de Clima Espacial (LANCE) - of Mexico has different ground based instruments to study and monitor the space weather. One of these instruments is the Mexican Array Radio Telescope (MEXART) which is principally dedicated to remote sensing the solar wind and coronal mass ejections (CMEs) at 140 MHz, the instrument can detect solar wind densities and speeds from about 0.4 to 1 AU by modeling observations of interplanetary scintillation (IPS). MEXART is also able to detect ionospheric disturbances associated with transient space weather events by the analysis of ionospheric scintillation (IONS) . Additionally, MEXART has followed the Sun since the beginning of the current Solar Cycle 24 with records of 8 minutes per day, and occasionally, has partially detected the process of strong solar flares. Here we show the contributions of MEXART to the LANCE by reporting recent detections of CMEs by IPS, the arrive of transient events at Earth by IONS, the influence of active regions in the flux of the Sun at 140 MHz and the detection of a M6.5 class flare. Furthermore we report the status of a near real time analysis of IPS data for forecast purposes and the potential contribution to the Worldwide IPS Stations network (WIPSS), which is an effort to achieve a better coverage of the solar wind observations in the inner heliosphere.

  13. Dynamics Explorer 2: Continued FPI and NACS instrument data analysis and associated scientific activity at the University of Michigan

    NASA Technical Reports Server (NTRS)

    Burns, Alan; Killeen, T. L.

    1993-01-01

    The grant entitled 'Dynamics Explorer 2 - continued FPI and NACS instrument data analysis and associated scientific activity at the University of Michigan' is a continuation of a grant that began with instrument development for the Dynamics Explorer 2 (DE 2) satellite. Over the years, many publications and presentations at scientific meetings have occurred under the aegis of this grant. This present report details the progress that has been made in the final three years of the grant. In these last 4 years of the grant 26 papers have been published or are in press and about 10 more are in preparation or have been submitted. A large number of presentations have been made in the same time span: 36 are listed in Appendix 2. Evidence of the high educational utility of this research is indicated by the list of Ph. D. and M. S. theses that have been completed in the last 3 years that have involved work connected with NAG5-465. The structure of this report is as follows: a brief synopsis of the aims of the grant NAG5-465 is given in the next section; then there is a summary of the scientific accomplishments that have occurred over the grant period; last, we make some brief concluding remarks. Reprints of articles that have recently appeared in refereed journals are appended to the end of this document.

  14. Position requirements for space station personnel and linkages to portable microcomputer performance assessment

    NASA Technical Reports Server (NTRS)

    Jeanneret, P. R.

    1988-01-01

    The development and use of a menu of performance tests that can be self-administered on a portable microcomputer are investigated. In order to identify, develop, or otherwise select the relevant human capabilities/attributes to measure and hence include in the performance battery, it is essential that an analysis be conducted of the jobs or functions that will be performed throughout a space shuttle mission. The primary job analysis instrument, the Position Analysis Questionnaire (PAQ), is discussed in detail so the reader will have sufficient background for understanding the application of the instrument to the various work activities included within the scope of the study, and the derivation of the human requirements (abilities/attributes) from the PAQ analyses. The research methodology is described and includes the procedures used for gathering the PAQ data. The results are presented in detail with specific emphasis on identifying critical requirements that can be measured with a portable computerized assessment battery. A discussion of the results is given with implications for future research.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gilliland, Ronald L.; Ramsey, Lawrence W.; Chaplin, William J.

    An earlier study of the Kepler Mission noise properties on timescales of primary relevance to detection of exoplanet transits found that higher than expected noise followed, to a large extent, from the stars rather than instrument or data analysis performance. The earlier study over the first six quarters of Kepler data is extended to the full four years ultimately comprising the mission. Efforts to improve the pipeline data analysis have been successful in reducing noise levels modestly as evidenced by smaller values derived from the current data products. The new analyses of noise properties on transit timescales show significant changesmore » in the component attributed to instrument and data analysis, with essentially no change in the inferred stellar noise. We also extend the analyses to timescales of several days, instead of several hours to better sample stellar noise that follows from magnetic activity. On the longer timescale there is a shift in stellar noise for solar-type stars to smaller values in comparison to solar values.« less

  16. Senior high school students’ need analysis of Three-Tier Multiple Choice (3TMC) diagnostic test about acid-base and solubility equilibrium

    NASA Astrophysics Data System (ADS)

    Ardiansah; Masykuri, M.; Rahardjo, S. B.

    2018-05-01

    Students’ conceptual understanding is the most important comprehension to obtain related comprehension. However, they held their own conception. With this need analysis, we will elicit student need of 3TMC diagnostic test to measure students’ conception about acid-base and solubility equilibrium. The research done by a mixed method using questionnaire analysis based on descriptive of quantitative and qualitative. The research subject was 96 students from 4 senior high schools and 4 chemistry teachers chosen by random sampling technique. Data gathering used a questionnaire with 10 questions for student and 28 questions for teachers. The results showed that 97% of students stated that the development this instrument is needed. In addition, there were several problems obtained in this questionnaire include learning activity, teacher’s test and guessing. In conclusion, this is necessary to develop the 3TMC instrument that can diagnose and measure the student’s conception in acid-base and solubility equilibrium.

  17. Instrumentation of sampling aircraft for measurement of launch vehicle effluents

    NASA Technical Reports Server (NTRS)

    Wornom, D. E.; Woods, D. C.; Thomas, M. E.; Tyson, R. W.

    1977-01-01

    An aircraft was selected and instrumented to measure effluents emitted from large solid propellant rockets during launch activities. The considerations involved in aircraft selection, sampling probes, and instrumentation are discussed with respect to obtaining valid airborne measurements. Discussions of the data acquisition system used, the instrument power system, and operational sampling procedures are included. Representative measurements obtained from an actual rocket launch monitoring activity are also presented.

  18. A Content Analysis of Functional Recovery Strategies of Breast Cancer Survivors

    PubMed Central

    Lyons, Kathleen D.; Svensborn, Ingrid A.; Kornblith, Alice B.; Hegel, Mark T.

    2015-01-01

    Seventeen breast cancer survivors completed a six-week, telephone-delivered, Behavioral Activation/Problem-solving intervention designed to reduce participation restrictions. A content analysis of the session data was conducted to identify the goals and patterns of goal attainment, in order to understand what women were trying to achieve in their recovery. The 17 women set 141 goals. Sixty-six (47%) of the goals reflected a desire to add a new activity to their routine and 75 (53%) of the goals reflected a desire to perform a routine activity more efficiently. The women set goals to address challenges in exercising (24%), work (13%), nutrition (11%), instrumental activities of daily living (IADLs; 10%), stress management (9%), and social activities (9%). The women set an average of 8 goals and met 71% of their goals. The intervention shows promise in helping women set and achieve a number of functional goals as part of breast cancer recovery. PMID:26460469

  19. Design and validation of a standards-based science teacher efficacy instrument

    NASA Astrophysics Data System (ADS)

    Kerr, Patricia Reda

    National standards for K--12 science education address all aspects of science education, with their main emphasis on curriculum---both science subject matter and the process involved in doing science. Standards for science teacher education programs have been developing along a parallel plane, as is self-efficacy research involving classroom teachers. Generally, studies about efficacy have been dichotomous---basing the theoretical underpinnings on the work of either Rotter's Locus of Control theory or on Bandura's explanations of efficacy beliefs and outcome expectancy. This study brings all three threads together---K--12 science standards, teacher education standards, and efficacy beliefs---in an instrument designed to measure science teacher efficacy with items based on identified critical attributes of standards-based science teaching and learning. Based on Bandura's explanation of efficacy being task-specific and having outcome expectancy, a developmental, systematic progression from standards-based strategies and activities to tasks to critical attributes was used to craft items for a standards-based science teacher efficacy instrument. Demographic questions related to school characteristics, teacher characteristics, preservice background, science teaching experience, and post-certification professional development were included in the instrument. The instrument was completed by 102 middle level science teachers, with complete data for 87 teachers. A principal components analysis of the science teachers' responses to the instrument resulted in two components: Standards-Based Science Teacher Efficacy: Beliefs About Teaching (BAT, reliability = .92) and Standards-Based Science Teacher Efficacy: Beliefs About Student Achievement (BASA, reliability = .82). Variables that were characteristic of professional development activities, science content preparation, and school environment were identified as members of the sets of variables predicting the BAT and BASA subscales. Correlations were computed for BAT, BASA, and demographic variables to identify relationships between teacher efficacy, teacher characteristics, and school characteristics. Further research is recommended to refine the instrument and apply its use to a larger sample of science teachers. Its further development also has significance for the enhancement of science teacher education programs.

  20. Low activated incore instrument

    DOEpatents

    Ekeroth, Douglas E.

    1994-01-01

    Instrumentation for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials.

  1. Preliminary Results for the PAR-PRO: A Measure of Home and Community Participation

    PubMed Central

    Ostir, Glenn V.; Granger, Carl V.; Black, Terrie; Roberts, Pamela; Burgos, Laura; Martinkewiz, Paula; Ottenbacher, Kenneth J.

    2007-01-01

    Objective To develop a measure of home and community participation related to the World Health Organization’s International Classification of Functioning, Disability and Health. Design Cross-sectional analysis of survey data. Setting Nine medical inpatient rehabilitation facilities from 6 states. Participants A total of 594 patients of mixed impairment type admitted for inpatient rehabilitation in 2002. Mean age was 74.0 years and 61.4% were women. Interventions Not applicable. Main Outcome Measures Reliability and validity of the participation instrument. Results A 20-item instrument of home and community participation was developed (PAR-PRO). The instrument showed good internal consistency and good Rasch person and item fit statistics. Four subfactors were identified beyond the unidimensional construct of participation including domestic management, socialization, physical vigor, and generative activities. The PAR-PRO total participation score correlated inversely with age (r=−.31, P<.001) but did not differ by sex. Conclusions The 20-item PAR-PRO instrument of home and community participation displayed good psychometric characteristics. The instrument shows promise as a broad measure of home and community involvement for persons with disabilities. Further work is needed to support its application for people without disability. PMID:16876548

  2. Student mathematical imagination instruments: construction, cultural adaptation and validity

    NASA Astrophysics Data System (ADS)

    Dwijayanti, I.; Budayasa, I. K.; Siswono, T. Y. E.

    2018-03-01

    Imagination has an important role as the center of sensorimotor activity of the students. The purpose of this research is to construct the instrument of students’ mathematical imagination in understanding concept of algebraic expression. The researcher performs validity using questionnaire and test technique and data analysis using descriptive method. Stages performed include: 1) the construction of the embodiment of the imagination; 2) determine the learning style questionnaire; 3) construct instruments; 4) translate to Indonesian as well as adaptation of learning style questionnaire content to student culture; 5) perform content validation. The results stated that the constructed instrument is valid by content validation and empirical validation so that it can be used with revisions. Content validation involves Indonesian linguists, english linguists and mathematics material experts. Empirical validation is done through a legibility test (10 students) and shows that in general the language used can be understood. In addition, a questionnaire test (86 students) was analyzed using a biserial point correlation technique resulting in 16 valid items with a reliability test using KR 20 with medium reability criteria. While the test instrument test (32 students) to find all items are valid and reliability test using KR 21 with reability is 0,62.

  3. Reduction in bacterial counts in infected root canals after rotary or hand nickel-titanium instrumentation--a clinical study.

    PubMed

    Rôças, I N; Lima, K C; Siqueira, J F

    2013-07-01

    To compare the antibacterial efficacy of two instrumentation techniques, one using hand nickel-titanium (NiTi) instruments and the other using rotary NiTi instruments, in root canals of teeth with apical periodontitis. Root canals from single-rooted teeth were instrumented using either hand NiTi instruments in the alternated rotation motion technique or rotary BioRaCe instruments. The irrigant used in both groups was 2.5% NaOCl. DNA extracts from samples taken before and after instrumentation were subjected to quantitative analysis by real-time polymerase chain reaction (qPCR). Qualitative analysis was also performed using presence/absence data from culture and qPCR assays. Bacteria were detected in all S1 samples by both methods. In culture analysis, 45% and 35% of the canals were still positive for bacterial presence after hand and rotary NiTi instrumentation, respectively (P > 0.05). Rotary NiTi instrumentation resulted in significantly fewer qPCR-positive cases (60%) than hand NiTi instrumentation (95%) (P = 0.01). Intergroup comparison of quantitative data showed no significant difference between the two techniques. There was no significant difference in bacterial reduction in infected canals after instrumentation using hand or rotary NiTi instruments. In terms of incidence of positive results for bacteria, culture also showed no significant differences between the groups, but the rotary NiTi instrumentation resulted in more negative results in the more sensitive qPCR analysis. © 2013 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  4. Tutorial in Biostatistics: Instrumental Variable Methods for Causal Inference*

    PubMed Central

    Baiocchi, Michael; Cheng, Jing; Small, Dylan S.

    2014-01-01

    A goal of many health studies is to determine the causal effect of a treatment or intervention on health outcomes. Often, it is not ethically or practically possible to conduct a perfectly randomized experiment and instead an observational study must be used. A major challenge to the validity of observational studies is the possibility of unmeasured confounding (i.e., unmeasured ways in which the treatment and control groups differ before treatment administration which also affect the outcome). Instrumental variables analysis is a method for controlling for unmeasured confounding. This type of analysis requires the measurement of a valid instrumental variable, which is a variable that (i) is independent of the unmeasured confounding; (ii) affects the treatment; and (iii) affects the outcome only indirectly through its effect on the treatment. This tutorial discusses the types of causal effects that can be estimated by instrumental variables analysis; the assumptions needed for instrumental variables analysis to provide valid estimates of causal effects and sensitivity analysis for those assumptions; methods of estimation of causal effects using instrumental variables; and sources of instrumental variables in health studies. PMID:24599889

  5. Evaluation of low-cost, objective instruments for assessing physical activity in 10-11-year-old children.

    PubMed

    Hart, Teresa L; Brusseau, Timothy; Kulinna, Pamela Hodges; McClain, James J; Tudor-Locke, Catrine

    2011-12-01

    This study compared step counts detected by four, low-cost, objective, physical-activity-assessment instruments and evaluated their ability to detect moderate-to-vigorous physical activity (MVPA) compared to the ActiGraph accelerometer (AG). Thirty-six 10-11-year-old children wore the NL-1000, Yamax Digiwalker SW 200, Omron HJ-151, and Walk4Life MVP concurrently with the AG during school hours on a single day. AG MVPA was derived from activity count data using previously validated cut points. Two of the evaluated instruments provided similar group mean MVPA and step counts compared to AG (dependent on cut point). Low-cost instruments may be useful for measurement of both MVPA and steps in children's physical activity interventions and program evaluation.

  6. Multitrait-Multimethod Analyses of Two Self-Concept Instruments.

    ERIC Educational Resources Information Center

    Marsh, Herbert W.; Smith, Ian D.

    1982-01-01

    The multidimensionality of self-concept and the use of factor analysis in the development of self-concept instruments are supported in multitrait-multimethod analyses of the Sears and Coopersmith instruments. Convergent validity and discriminate validity of subscales in factor analysis and multitrait-multimethod analysis of longitudinal data are…

  7. Schematic of Sample Analysis at Mars SAM Instrument

    NASA Image and Video Library

    2011-01-18

    This schematic illustration for NASA Mars Science Laboratory Sample Analysis at Mars SAM instrument shows major components of the microwave-oven-size instrument, which will examine samples of Martian rocks, soil and atmosphere.

  8. Creating and validating an instrument to identify the workload at an oncology and hematology outpatient service

    PubMed Central

    Martin, Lelia Gonçalves Rocha; Gaidzinski, Raquel Rapone

    2014-01-01

    Objective Construct and to validate an instrument for measuring the time spent by nursing staff in the interventions/activities in Outpatient Oncology and Hematology, interventions based on Nursing Interventions Classification (NIC), for key areas of Pediatric Oncology and Oncology Nursing. Methods Cross-sectional study divided into two steps: (1) construction of an instrument to measure the interventions/Nursing activities and (2) validation of this instrument. Results We selected 32 essential interventions from NIC for Pediatric Oncology and Oncology Nursing areas. The judges agreed with removing 13 and including 6 interventions in the instrument, beyond personal activity. Conclusion The choice of essential interventions from NIC is justified by the gain time on research. PMID:25295454

  9. Acquisition of an instrumental activity of daily living in patients with Korsakoff's syndrome: a comparison of trial and error and errorless learning.

    PubMed

    Oudman, Erik; Nijboer, Tanja C W; Postma, Albert; Wijnia, Jan W; Kerklaan, Sandra; Lindsen, Karen; Van der Stigchel, Stefan

    2013-01-01

    Patients with Korsakoff's syndrome show devastating amnesia and executive deficits. Consequently, the ability to perform instrumental activities such as making coffee is frequently diminished. It is currently unknown whether patients with Korsakoff's syndrome are able to (re)learn instrumental activities. A good candidate for an effective teaching technique in Korsakoff's syndrome is errorless learning as it is based on intact implicit memory functioning. Therefore, the aim of the current study was two-fold: to investigate whether patients with Korsakoff's syndrome are able to (re)learn instrumental activities, and to compare the effectiveness of errorless learning with trial and error learning in the acquisition and maintenance of an instrumental activity, namely using a washing machine to do the laundry. Whereas initial learning performance in the errorless learning condition was superior, both intervention techniques resulted in similar improvement over eight learning sessions. Moreover, performance in a different spatial layout showed a comparable improvement. Notably, in follow-up sessions starting after four weeks without practice, performance was still elevated in the errorless learning condition, but not in the trial and error condition. The current study demonstrates that (re)learning and maintenance of an instrumental activity is possible in patients with Korsakoff's syndrome.

  10. Assessing Learning Outcomes: An Analysis of the Goals-2 Instrument

    ERIC Educational Resources Information Center

    Sabbag, Anelise Guimaraes; Zieffler, Andrew

    2015-01-01

    The test instrument GOALS-2 was designed primarily to evaluate the effectiveness of the CATALST curriculum. The purpose of this study was to perform a psychometric analysis of this instrument. Undergraduate students from six universities in the United States (n = 289) were administered the instrument. Three measurement models were fit and…

  11. Authentic Performance in the Instrumental Analysis Laboratory: Building a Visible Spectrophotometer Prototype

    ERIC Educational Resources Information Center

    Wilson, Mark V.; Wilson, Erin

    2017-01-01

    In this work we describe an authentic performance project for Instrumental Analysis in which students designed, built, and tested spectrophotometers made from simple components. The project addressed basic course content such as instrument design principles, UV-vis spectroscopy, and spectroscopic instrument components as well as skills such as…

  12. [Factors Influencing Physical Activity among Community-dwelling Older Adults with Type 2 Diabetes: A Path Analysis].

    PubMed

    Jang, Sun Joo; Park, Hyunju; Kim, Hyunjung; Chang, Sun Ju

    2015-06-01

    The purpose of the study was to identify factors influencing physical activity among community-dwelling older adults with type 2 diabetes. The study design was based on the Theory of Triadic Influence. A total of 242 older adults with type 2 diabetes participated in this study. Six variables related to physical activity in older adults, including self-efficacy, social normative belief, attitudes, intention, experience, and level of physical activity, were measured using reliable instruments. Data were analyzed using descriptive statistics, Pearson's correlation analyses, and a path analysis. The mean physical activity score was 104.2, range from zero to 381.21. The path analysis showed that self-efficacy had the greatest total effect on physical activity. Also, experience had direct and total effects on physical activity as well as mediated the paths of social normative beliefs to attitudes and intention to physical activity. These factors accounted for 10% of the total variance, and the fit indices of the model satisfied the criteria of fitness. The findings of the study reveal the important role of self-efficacy and past experience in physical activity in older adults with type 2 diabetes.

  13. Radiofrequency energy antenna coupling to common laparoscopic instruments: practical implications.

    PubMed

    Jones, Edward L; Robinson, Thomas N; McHenry, Jennifer R; Dunn, Christina L; Montero, Paul N; Govekar, Henry R; Stiegmann, Greg V

    2012-11-01

    Electromagnetic coupling can occur between the monopolar "Bovie" instrument and other laparoscopic instruments without direct contact by a phenomenon termed antenna coupling. The purpose of this study was to determine if, and to what extent, radiofrequency energy couples to other common laparoscopic instruments and to describe practical steps that can minimize the magnitude of antenna coupling. In a laparoscopic simulator, monopolar radiofrequency energy was delivered to an L-hook. The tips of standard, nonelectrical laparoscopic instruments (either an unlit 10 mm telescope or a 5 mm grasper) were placed adjacent to bovine liver tissue and were never in contact with the active electrode. Thermal imaging quantified the change in tissue temperature nearest the tip of the telescope or grasper at the end of a 5 s activation of the active electrode. A 5 s activation (30 watts, coagulation mode, 4 cm separation between instruments) increased tissue temperature compared with baseline adjacent to the grasper tip (2.2 ± 2.2 °C; p = 0.013) and telescope tip (38.2 ± 8.0 °C; p < 0.001). The laparoscopic telescope tip increased tissue temperature more than the laparoscopic grasper tip (p < 0.001). Lowering the generator power from 30 to 15 Watts decreased the heat generated at the telescope tip (38.2 ± 8.0 vs. 13.5 ± 7.5 °C; p < 0.001). Complete separation of the camera/light cords and the active electrode cord decreased the heat generated near the telescope tip compared with parallel bundling of the cords (38.2 ± 8.0 vs. 15.7 ± 11.6 °C; p < 0.001). Commonly used laparoscopic instruments couple monopolar radiofrequency energy without direct contact with the active electrode, a phenomenon that results in heat transfer from a nonelectrically active instrument tip to adjacent tissue. Practical steps to minimize heat transfer resulting from antenna coupling include reducing the monopolar generator power setting and avoiding of parallel bundling of the telescope and active electrode cords.

  14. Superconducting gravity gradiometer mission. Volume 1: Study team executive summary

    NASA Technical Reports Server (NTRS)

    Morgan, Samuel H. (Editor); Paik, Ho Jung (Editor)

    1989-01-01

    An executive summary is presented based upon the scientific and engineering studies and developments performed or directed by a Study Team composed of various Federal and University activities involved with the development of a three-axis Superconducting Gravity Gradiometer integrated with a six-axis superconducting accelerometer. This instrument is being developed for a future orbital mission to make precise global gravity measurements. The scientific justification and requirements for such a mission are discussed. This includes geophysics, the primary mission objective, as well as secondary objectives, such as navigation and tests of fundamental laws of physics, i.e., a null test of the inverse square law of gravitation and tests of general relativity. The instrument design and status along with mission analysis, engineering assessments, and preliminary spacecraft concepts are discussed. In addition, critical spacecraft systems and required technology advancements are examined. The mission requirements and an engineering assessment of a precursor flight test of the instrument are discussed.

  15. The Hessdalen Luminous Phenomenon: A Data Analysis

    NASA Astrophysics Data System (ADS)

    Teodorani, M.; Strand, E. P.

    1998-08-01

    In the period 21 January - 26 February 1984, a group of research engineers belonging to "Project Hessdalen", carried out instrumental investigations on a luminous atmospheric phenomenon occurring with strong recurrence in the area of Hessdalen in Norway. Several multi-mode instruments were used in order to monitor the phenomenon. In the present work, an analytical attempt, based on the data achieved during the 1984 investigation period, has been done in order to explain such a phenomenon. The following main results are presented: (1) the luminous phenomenon occurs with a periodicity of about one day and is approximately coincident with some peculiar magnetic pulsations and, more scarcely, with some components of radio emission; (2) magnetometric data, radar data and some components of radiometric data show some slight correlation with daily solar activity. Hypothesis regarding formation of solar-driven plasmoids acquiring self-governing EM and magnetic fields, is further ventured and discussed. Technical requirements for future instrumental research are presented as well.

  16. Superconducting gravity gradiometer mission. Volume 2: Study team technical report

    NASA Technical Reports Server (NTRS)

    Morgan, Samuel H. (Editor); Paik, Ho Jung (Editor)

    1988-01-01

    Scientific and engineering studies and developments performed or directed by a Study Team composed of various Federal and University activities involved with the development of a three-axis superconducting gravity gradiometer integrated with a six-axis superconducting accelerometer are examined. This instrument is being developed for a future orbital mission to make precise global gravity measurements. The scientific justification and requirements for such a mission are discussed. This includes geophysics, the primary mission objective, as well as secondary objective, such as navigation and feats of fundamental laws of physics, i.e., a null test of the inverse square law of gravitation and tests of general relativity. The instrument design and status along with mission analysis, engineering assessments, and preliminary spacecraft concepts are discussed. In addition, critical spacecraft systems and required technology advancements are examined. The mission requirements and an engineering assessment of a precursor flight test of the instrument are discussed.

  17. Thermodynamic Performance of the 3-Stage ADR for the Astro-H Soft X-Ray Spectrometer Instrument

    NASA Technical Reports Server (NTRS)

    Shirron, Peter J.; Kimball, Mark O.; James, Bryan L.; Muench, Theodore; DiPirro, Michael J.; Bialas, Thomas G.; Sneiderman, Gary A.; Porter, Frederick S.; Kelley, Richard L.

    2015-01-01

    The Soft X-ray Spectrometer (SXS) instrument[1] on Astro-H[2] will use a 3-stage ADR[3] to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at =1.20 K as the heat sink[4]. In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and singleshot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

  18. Nitrifying bacterial biomass and nitrification activity evaluated by FISH and an automatic on-line instrument at full-scale Fusina (Venice, Italy) WWTP.

    PubMed

    Badoer, S; Miana, P; Della Sala, S; Marchiori, G; Tandoi, V; Di Pippo, F

    2015-12-01

    In this study, monthly variations in biomass of ammonia-oxidizing bacteria (AOB) and nitrite-oxidizing bacteria (NOB) were analysed over a 1-year period by fluorescence in situ hybridization (FISH) at the full-scale Fusina WWTP. The nitrification capacity of the plant was also monitored using periodic respirometric batch tests and by an automated on-line titrimetric instrument (TITrimetric Automated ANalyser). The percentage of nitrifying bacteria in the plant was the highest in summer and was in the range of 10-15 % of the active biomass. The maximum nitrosation rate varied in the range 2.0-4.0 mg NH4 g(-1) VSS h(-1) (0.048-0.096 kg TKN kg(-1) VSS day(-1)): values obtained by laboratory measurements and the on-line instrument were similar and significantly correlated. The activity measurements provided a valuable tool for estimating the maximum total Kjeldahl nitrogen (TKN) loading possible at the plant and provided an early warning of whether the TKN was approaching its limiting value. The FISH analysis permitted determination of the nitrifying biomass present. The main operational parameter affecting both the population dynamics and the maximum nitrosation activity was mixed liquor volatile suspended solids (MLVSS) concentration and was negatively correlated with ammonia-oxidizing bacteria (AOB) (p = 0.029) and (NOB) (p = 0.01) abundances and positively correlated with maximum nitrosation rates (p = 0.035). Increases in concentrations led to decreases in nitrifying bacteria abundance, but their nitrosation activity was higher. These results demonstrate the importance of MLVSS concentration as key factor in the development and activity of nitrifying communities in wastewater treatment plants (WWTPs). Operational data on VSS and sludge volume index (SVI) values are also presented on 11-year basis observations.

  19. Developing a multisource feedback tool for postgraduate medical educational supervisors.

    PubMed

    Archer, Julian; Swanwick, Tim; Smith, Daniel; O'Keeffe, Catherine; Cater, Nerys

    2013-01-01

    Supervisors play a key role in the development of postgraduate medical trainees both in the oversight of their day-to-day clinical practice but also in the support of their learning experiences. In the UK, there has been a clear distinction made between these two activities. In this article, we report on the development of a web-based multisource feedback (MSF) tool for educational supervisors in the London Deanery, an organisation responsible for 20% of the UK's doctors and dentists in training. A narrative review of the literature generated a question framework for a series of focus groups. Data were analysed using an interpretative thematic approach and the resulting instrument piloted online. Instrument performance was analysed using a variety of tools including factor analysis, generalisability theory and analysis of performance in the first year of implementation. Two factors were initially identified. Three questions performed inadequately and were subsequently discarded. Educational supervisors scored well, generally rating themselves lower than they were by their trainees. The instrument was launched in July 2010, requiring five respondents to generate a summated report, with further validity evidence collated over the first year if implementation. Arising out of a robust development process, the London Deanery MSF instrument for educational supervisors is a tool that demonstrates considerable evidence of validity and can provide supervisors with useful evidence of their effectiveness.

  20. Surgical instrument similarity metrics and tray analysis for multi-sensor instrument identification

    NASA Astrophysics Data System (ADS)

    Glaser, Bernhard; Schellenberg, Tobias; Franke, Stefan; Dänzer, Stefan; Neumuth, Thomas

    2015-03-01

    A robust identification of the instrument currently used by the surgeon is crucial for the automatic modeling and analysis of surgical procedures. Various approaches for intra-operative surgical instrument identification have been presented, mostly based on radio-frequency identification (RFID) or endoscopic video analysis. A novel approach is to identify the instruments on the instrument table of the scrub nurse with a combination of video and weight information. In a previous article, we successfully followed this approach and applied it to multiple instances of an ear, nose and throat (ENT) procedure and the surgical tray used therein. In this article, we present a metric for the suitability of the instruments of a surgical tray for identification by video and weight analysis and apply it to twelve trays of four different surgical domains (abdominal surgery, neurosurgery, orthopedics and urology). The used trays were digitized at the central sterile services department of the hospital. The results illustrate that surgical trays differ in their suitability for the approach. In general, additional weight information can significantly contribute to the successful identification of surgical instruments. Additionally, for ten different surgical instruments, ten exemplars of each instrument were tested for their weight differences. The samples indicate high weight variability in instruments with identical brand and model number. The results present a new metric for approaches aiming towards intra-operative surgical instrument detection and imply consequences for algorithms exploiting video and weight information for identification purposes.

  1. Masticatory muscle activity assessment and reliability of a portable electromyographic instrument.

    PubMed

    Bowley, J F; Marx, D B

    2001-03-01

    Masticatory muscle hyperactivity is thought to produce muscle pain and tension headaches and can cause excessive wear or breakage of restorative dental materials used in the treatment of prosthodontic patients. The quantification and identification of this type of activity is an important consideration in the preoperative diagnosis and treatment planning phase of prosthodontic care. This study investigated the quantification process in complete denture/overdenture patients with natural mandibular tooth abutments and explored the reliability of instrumentation used to assess this parafunctional activity. The nocturnal EMG activity in asymptomatic complete denture/overdenture subjects was assessed with and without prostheses worn during sleep. Because of the large variance within and between subjects, the investigators evaluated the reliability of the 3 instruments used to test nocturnal EMG activity in the sample. Electromyographic activity data of denture/overdenture subjects revealed no differences between prostheses worn versus not worn during sleep but demonstrated a very large variance factor. Further investigation of the instrumentation demonstrated a consistent in vitro as well as in vivo reliability in controlled laboratory studies. The portable EMG instrumentation used in this study revealed a large, uncontrollable variance factor within and between subjects that greatly complicated the diagnosis of parafunctional activity in prosthodontic patients.

  2. Instrumental and bioanalytical measures of dioxin-like compounds and activities in sediments of the Pohang Area, Korea.

    PubMed

    Hong, Seongjin; Khim, Jong Seong; Park, Jinsoon; Kim, Sunmi; Lee, Sangwoo; Choi, Kyungho; Kim, Chul-Su; Choi, Sung-Deuk; Park, Jeongim; Ryu, Jongseong; Jones, Paul D; Giesy, John P

    2014-02-01

    Pohang is a mid-sized city in which Korea's largest manufacturer of steel is located. The Hyeongsan River, which runs through Pohang and empties into Yeongil Bay, is therefore expected to be affected by various municipal and industrial inputs. In order to characterize aryl hydrocarbon receptor (AhR)-mediated activities in sediments from the Pohang area, a total of eight locations along the Hyeongsan River were chosen and 16 sediment samples were collected during two sampling campaigns in 2010. Organic extracts of sediments were characterized by both quantitative chemical analyses of dioxin-like chemicals and the in vitro H4IIE-luc bioassay. Significant dioxin-like activities were observed in sediments from industrial and municipal areas, which indicates that most of the dioxin-like chemicals were associated with surrounding anthropogenic sources. In general, responses of the H4IIE-luc assay were significantly correlated with concentrations of target compounds including dioxins, furans, co-planar PCBs, and dioxin-like PAHs. A potency balance analysis indicated that instrumentally derived TCDD equivalents (TEQs) explained about 77% of the bioassay-derived TCDD equivalents (TCDD-EQs). Among the target chemicals measured, certain penta-chlorinated dioxin and furan compounds accounted for the majority of dioxin-like activities associated with sediments. Compositional analysis of target chemicals the sources of such dioxin-like activities were mainly derived from the local activities such as the iron and steel industries. Concentrations and activities of AhR agonists were similar to what was measured approximately 10 years ago. Thus, while AhR agonists seem to be persistent in sediments there seem to have been no large increases in these chemicals in the Pohang area. © 2013. Published by Elsevier B.V. All rights reserved.

  3. Energy and Environment Division annual report, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camp, J.A.

    1978-01-01

    Research activities of this Division are reported under nine separate programs, namely: Energy Analysis; Solar Energy; Energy-Efficient Buildings; Chemical Process Research and Development; Environmental Research; Atmospheric Aerosol Research; Oil Shale Research; Instrumentation Development; and Combustion Research. A separate abstract was prepared for each of the nine programs, each of which contained several individual research summaries, with responsible researchers listed. All of the abstracts will appear in Energy Research Abstracts (ERA), and five will appear in Energy Abstracts for Policy Analysis (EAPA).

  4. Correcting for the effects of pupil discontinuities with the ACAD method

    NASA Astrophysics Data System (ADS)

    Mazoyer, Johan; Pueyo, Laurent; N'Diaye, Mamadou; Mawet, Dimitri; Soummer, Rémi; Norman, Colin

    2016-07-01

    The current generation of ground-based coronagraphic instruments uses deformable mirrors to correct for phase errors and to improve contrast levels at small angular separations. Improving these techniques, several space and ground based instruments are currently developed using two deformable mirrors to correct for both phase and amplitude errors. However, as wavefront control techniques improve, more complex telescope pupil geometries (support structures, segmentation) will soon be a limiting factor for these next generation coronagraphic instruments. The technique presented in this proceeding, the Active Correction of Aperture Discontinuities method, is taking advantage of the fact that most future coronagraphic instruments will include two deformable mirrors, and is proposing to find the shapes and actuator movements to correct for the effect introduced by these complex pupil geometries. For any coronagraph previously designed for continuous apertures, this technique allow to obtain similar performance in contrast with a complex aperture (with segmented and secondary mirror support structures), with high throughput and flexibility to adapt to changing pupil geometry (e.g. in case of segment failure or maintenance of the segments). We here present the results of the parametric analysis realized on the WFIRST pupil for which we obtained high contrast levels with several deformable mirror setups (size, separation between them), coronagraphs (Vortex charge 2, vortex charge 4, APLC) and spectral bandwidths. However, because contrast levels and separation are not the only metrics to maximize the scientific return of an instrument, we also included in this study the influence of these deformable mirror shapes on the throughput of the instrument and sensitivity to pointing jitters. Finally, we present results obtained on another potential space based telescope segmented aperture. The main result of this proceeding is that we now obtain comparable performance than the coronagraphs previously designed for WFIRST. First result from the parametric analysis strongly suggest that the 2 deformable mirror set up (size and distance between them) have a important impact on the performance in contrast and throughput of the final instrument.

  5. Comparison of soil pollution concentrations determined using AAS and portable XRF techniques.

    PubMed

    Radu, Tanja; Diamond, Dermot

    2009-11-15

    Past mining activities in the area of Silvermines, Ireland, have resulted in heavily polluted soils. The possibility of spreading pollution to the surrounding areas through dust blow-offs poses a potential threat for the local communities. Conventional environmental soil and dust analysis techniques are very slow and laborious and consequently there is a need for fast and accurate analytical methods, which can provide real-time in situ pollution mapping. Laboratory-based aqua regia acid digestion of the soil samples collected in the area followed by the atomic absorption spectrophotometry (AAS) analysis confirmed very high pollution, especially by Pb, As, Cu, and Zn. In parallel, samples were analyzed using portable X-ray fluorescence radioisotope and miniature tube powered (XRF) NITON instruments and their performance was compared. Overall, the portable XRF instrument gave excellent correlation with the laboratory-based reference AAS method.

  6. Expression microdissection adapted to commercial laser dissection instruments

    PubMed Central

    Hanson, Jeffrey C; Tangrea, Michael A; Kim, Skye; Armani, Michael D; Pohida, Thomas J; Bonner, Robert F; Rodriguez-Canales, Jaime; Emmert-Buck, Michael R

    2016-01-01

    Laser-based microdissection facilitates the isolation of specific cell populations from clinical or animal model tissue specimens for molecular analysis. Expression microdissection (xMD) is a second-generation technology that offers considerable advantages in dissection capabilities; however, until recently the method has not been accessible to investigators. This protocol describes the adaptation of xMD to commonly used laser microdissection instruments and to a commercially available handheld laser device in order to make the technique widely available to the biomedical research community. The method improves dissection speed for many applications by using a targeting probe for cell procurement in place of an operator-based, cell-by-cell selection process. Moreover, xMD can provide improved dissection precision because of the unique characteristics of film activation. The time to complete the protocol is highly dependent on the target cell population and the number of cells needed for subsequent molecular analysis. PMID:21412274

  7. Study on bending behaviour of nickel–titanium rotary endodontic instruments by analytical and numerical analyses

    PubMed Central

    Tsao, C C; Liou, J U; Wen, P H; Peng, C C; Liu, T S

    2013-01-01

    Aim To develop analytical models and analyse the stress distribution and flexibility of nickel–titanium (NiTi) instruments subject to bending forces. Methodology The analytical method was used to analyse the behaviours of NiTi instruments under bending forces. Two NiTi instruments (RaCe and Mani NRT) with different cross-sections and geometries were considered. Analytical results were derived using Euler–Bernoulli nonlinear differential equations that took into account the screw pitch variation of these NiTi instruments. In addition, the nonlinear deformation analysis based on the analytical model and the finite element nonlinear analysis was carried out. Numerical results are obtained by carrying out a finite element method. Results According to analytical results, the maximum curvature of the instrument occurs near the instrument tip. Results of the finite element analysis revealed that the position of maximum von Mises stress was near the instrument tip. Therefore, the proposed analytical model can be used to predict the position of maximum curvature in the instrument where fracture may occur. Finally, results of analytical and numerical models were compatible. Conclusion The proposed analytical model was validated by numerical results in analysing bending deformation of NiTi instruments. The analytical model is useful in the design and analysis of instruments. The proposed theoretical model is effective in studying the flexibility of NiTi instruments. Compared with the finite element method, the analytical model can deal conveniently and effectively with the subject of bending behaviour of rotary NiTi endodontic instruments. PMID:23173762

  8. Quality of life of pediatric oncology patients: Do patient-reported outcome instruments measure what matters to patients?

    PubMed

    Anthony, Samantha J; Selkirk, Enid; Sung, Lillian; Klaassen, Robert J; Dix, David; Klassen, Anne F

    2017-02-01

    The assessment of quality of life (QOL) is key within pediatric oncology and requires a clearly defined construct of QOL. The purpose of our study was: (1) to conduct a qualitative study to inform the theoretical underpinnings of QOL and (2) to determine the appropriateness of patient-reported outcome (PRO) instruments to assess and evaluate QOL in pediatric cancer patients and survivors. The study used an interpretative description approach. Children diagnosed with childhood cancer, aged 8-18 years, were recruited from four Canadian hospitals. Semi-structured interviews were completed, transcribed verbatim and coded through methods of constant comparison. In-depth analysis facilitated a comparison between emerging themes and the content of commonly used PRO instruments. Thirty-seven children (19 females; 51 %) participated. The mean age was 13 years, and 19 (51 %) participants were post-treatment. Participant experiences reflected notions of positive and negative duality, including: maintaining physical functioning but longing for the ability to participate in activities; experiencing a new level of intimacy with family and friends amidst isolation; and developing positivity amidst anger, sadness and lingering worry. Analysis showed that existing PRO instruments are missing concerns specific to this population and contain content not reflective of the QOL experiences of childhood cancer patients and survivors. Our research highlights important problems with content validity of existing PRO scales, indicating that the tools we have to date have limited utility in research and clinical practice. The development of a new PRO instrument should be considered to ensure that content validity is achieved.

  9. Quantification of Daily Physical Activity

    NASA Technical Reports Server (NTRS)

    Whalen, Robert; Breit, Greg; Quintana, Jason

    1994-01-01

    The influence of physical activity on the maintenance and adaptation of musculoskeletal tissue is difficult to assess. Cumulative musculoskeletal loading is hard to quantify and the attributes of the daily tissue loading history affecting bone metabolism have not been completely identified. By monitoring the vertical component of the daily ground reaction force (GRFz), we have an indirect measure of cumulative daily lower limb musculoskeletal loading to correlate with bone density and structure. The objective of this research is to develop instrumentation and methods of analysis to quantify activity level in terms of the daily history of ground reaction forces.

  10. A compact ECG R-R interval, respiration and activity recording system.

    PubMed

    Yoshimura, Takahiro; Yonezawa, Yoshiharu; Maki, Hiromichi; Ogawa, Hidekuni; Hahn, Allen W; Thayer, Julian F; Caldwell, W Morton

    2003-01-01

    An ECG R-R interval, respiration and activity recording system has been developed for monitoring variability of heart rate and respiratory frequency during daily life. The recording system employs a variable gain instrumentation amplifier, an accelerometer, a low power 8-bit single-chip microcomputer and a 1024 KB EEPROM. It is constructed on three ECG chest electrodes. The R-R interval and respiration are detected from the ECG. Activity during walking and running is calculated from an accelerator. The detected data are stored in an EEPROM and after recording, are downloaded to a desktop computer for analysis.

  11. Planetary Geochemistry Using Active Neutron and Gamma Ray Instrumentation

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    The Pulsed Neutron Generator-Gamma Ray And Neutron Detector (PNG-GRAND) experiment is an innovative application of the active neutron-gamma ray technology so successfully used in oil field well logging and mineral exploration on Earth, The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring the PNG-GRAND instrument to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asterOIds, comets and the satellites of the outer planets, Gamma-Ray Spectrometers have been incorporated into numerous orbital planetary science missions and, especially in the case of Mars Odyssey, have contributed detailed maps of the elemental composition over the entire surface of Mars, Neutron detectors have also been placed onboard orbital missions such as the Lunar Reconnaissance Orbiter and Lunar Prospector to measure the hydrogen content of the surface of the moon, The DAN in situ experiment on the Mars Science Laboratory not only includes neutron detectors, but also has its own neutron generator, However, no one has ever combined the three into one instrument PNG-GRAND combines a pulsed neutron generator (PNG) with gamma ray and neutron detectors to produce a landed instrument that can determine subsurface elemental composition without drilling. We are testing PNG-GRAND at a unique outdoor neutron instrumentation test facility recently constructed at NASA/GSFC that consists of a 2 m x 2 m x 1 m granite structure in an empty field, We will present data from the operation of PNG-GRAND in various experimental configurations on a known sample in a geometry that is identical to that which can be achieved on a planetary surface. We will also compare the material composition results inferred from our experiments to both an independent laboratory elemental composition analysis and MCNPX computer modeling results,

  12. Active Region Soft X-Ray Spectra as Observed Using Sounding Rocket Measurements from the Solar Aspect Monitor (SAM), - a Modified SDO/EVE Instrument

    NASA Astrophysics Data System (ADS)

    Wieman, S. R.; Didkovsky, L. V.; Woods, T. N.; Jones, A. R.; Caspi, A.; Warren, H. P.

    2015-12-01

    Observations of solar active regions (ARs) in the soft x-ray spectral range (0.5 to 3.0 nm) were made on sounding rocket flight NASA 36.290 using a modified Solar Aspect Monitor (SAM), a pinhole camera on the EUV Variability Experiment (EVE) sounding rocket instrument. The suite of EVE rocket instruments is designed for under-flight calibrations of the orbital EVE on SDO. While the sounding rocket EVE instrument is for the most part a duplicate of the EVE on SDO, the SAM channel on the rocket version was modified in 2012 to include a free-standing transmission grating so that it could provide spectrally resolved images of the solar disk with the best signal to noise ratio for the brightest features on it, such as ARs. Calibrations of the EVE sounding rocket instrument at the National Institute of Standards and Technology Synchrotron Ultraviolet Radiation Facility (NIST SURF) have provided a measurement of the SAM absolute spectral response function and a mapping of wavelength separation in the grating diffraction pattern. For solar observations, this spectral separation is on a similar scale to the spatial size of the AR on the CCD, so dispersed AR images associated with emission lines of similar wavelength tend to overlap. Furthermore, SAM shares a CCD detector with MEGS-A, a separate EVE spectrometer channel, and artifacts of the MEGS-A signal (a set of bright spectral lines) appear in the SAM images. For these reasons some processing and analysis of the solar images obtained by SAM must be performed in order to determine spectra of the observed ARs. We present a method for determining AR spectra from the SAM rocket images and report initial soft X-ray spectra for two of the major active regions (AR11877 and AR11875) observed on flight 36.290 on 21 October 2013 at about 18:30 UT. We also compare our results with concurrent measurements from other solar soft x-ray instrumentation.

  13. Low activated incore instrument

    DOEpatents

    Ekeroth, D.E.

    1994-04-19

    Instrumentation is described for nuclear reactor head-mounted incore instrumentation systems fabricated of low nuclear cross section materials (i.e., zirconium or titanium). The instrumentation emits less radiation than that fabricated of conventional materials. 9 figures.

  14. Promoting Active Learning by Practicing the "Self-Assembly" of Model Analytical Instruments

    ERIC Educational Resources Information Center

    Algar, W. Russ; Krull, Ulrich J.

    2010-01-01

    In our upper-year instrumental analytical chemistry course, we have developed "cut-and-paste" exercises where students "build" models of analytical instruments from individual schematic images of components. These exercises encourage active learning by students. Instead of trying to memorize diagrams, students are required to think deeply about…

  15. Dopamine D1 and D2 Receptors in the Nucleus Accumbens Core and Shell Mediate Pavlovian-Instrumental Transfer

    ERIC Educational Resources Information Center

    Lex, Anja; Hauber, Wolfgang

    2008-01-01

    Pavlovian stimuli previously paired with food can markedly elevate the rate of food-reinforced instrumental responding. This effect, termed Pavlovian-instrumental transfer (PIT), depends both on general activating and specific cueing properties of Pavlovian stimuli. Recent evidence suggests that the general activating properties of Pavlovian…

  16. Physical Activity Measurement Instruments for Children with Cerebral Palsy: A Systematic Review

    ERIC Educational Resources Information Center

    Capio, Catherine M.; Sit, Cindy H. P.; Abernethy, Bruce; Rotor, Esmerita R.

    2010-01-01

    Aim: This paper is a systematic review of physical activity measurement instruments for field-based studies involving children with cerebral palsy (CP). Method: Database searches using PubMed Central, MEDLINE, CINAHL Plus, PsycINFO, EMBASE, Cochrane Library, and PEDro located 12 research papers, identifying seven instruments that met the inclusion…

  17. 17 CFR 240.3b-14 - Definition of cash management securities activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... derivative instruments or other financial instruments; (b) Cash management, in connection with any securities... § 240.15a-1 or any non-securities activities that involve eligible OTC derivative instruments or other... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Definition of cash management...

  18. Near Real Time website for IASI observations of atmospheric anomalies

    NASA Astrophysics Data System (ADS)

    Hayer, Catherine; Grainger, Don; Marsh, Kevin; Carboni, Elisa; Ventress, Lucy; Smith, Andrew

    2014-05-01

    Rapid analysis of satellite observations of the state of the atmosphere and the contaminant levels within it can be used for pollution monitoring, forest fire detection and volcanic activity monitoring. There are numerous operational satellite instruments for which this is possible. The IASI instruments, currently flying on board the MetOp-A and MetOp-B satellite platforms, are used to produce Near Real Time (NRT) data using analysis algorithms developed by Oxford University. The data is then displayed on a website within 3 hours of measurement. This allows for the semi-continuous monitoring of the state of the atmosphere over most of the globe, both in daylight and at night. Global coverage is achieved 4 times per day, which is a significant advantage over most of the alternatives, either geostationary, giving limited spatial coverage, or UV instruments which are only able to observe during the daylight side of the orbit. The website includes flags for atmospheric contaminants detectable by IASI, including dust, biomass burning-derived species and volcanic ash and SO2. In the near future, the website will be developed to also include a quantitative estimate of the mass loading of SO2 contained within any volcanic cloud. Emissions of volcanic products, such as ash and SO2, are useful indicators of a change in the activity level of a volcano. Since many volcanoes are only monitored by remote sensing methods, such as satellite instruments, this can be the only such indicator available. These emissions are also dangerous to passing aircraft, causing damage to external surfaces of the plane and to the engines, sometimes leading to failure. Evacuation of regions surrounding volcanoes, and cessation or diversion of air traffic around actively erupting volcanoes is costly and highly disruptive but is sometimes required. Up to date information is of critical importance as to when to make these sensitive decisions. An archive of data will be available to allow for easy comparison with previous related events, such as large dust storms, forest fires or volcanic eruptions over the whole of the IASI lifetime. The website is being developed in conjunction with the Centre for Environmental Data Archival (CEDA).

  19. Active Neutron and Gamma Ray Instrumentation for In Situ Planetary Science Applications

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Bodnarik, J.; Evans, L.; Floyd, S.; Lim, L.; McClanahan, T.; Namkung, M.; Schweitzer, J.; Starr, R.; Trombka, J.

    2010-01-01

    The Pulsed Neutron Generator-Gamma Ray And Neutron Detectors (PNG-GRAND) experiment is an innovative application of the active neutron-gamma ray technology so successfully used in oil field well logging and mineral exploration on Earth. The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA-GSFC) is to bring the PNG-GRAND instrument to the point where it can be flown on a variety of surface lander or rover missions to the Moon, Mars, Menus, asteroids, comets and the satellites of the outer planets. Gamma-Ray Spectrometers (GRS) have been incorporated into numerous orbital planetary science missions and, especially its the case of the Mars Odyssey GRS, have contributed detailed maps of the elemental composition over the entire surface of Mars. However, orbital gamma ray measurements have low spatial sensitivity (100's of km) due to their low surface emission rates from cosmic rays and subsequent need to be averaged over large surface areas. PNG-GRAND overcomes this impediment by incorporating a powerful neutron excitation source that permits high sensitivity surface and subsurface measurements of bulk elemental compositions. PNG-GRAND combines a pulsed neutron generator (PNG) with gamma ray and neutron detectors to produce a landed instrument to determine subsurface elemental composition without needing to drill into a planet's surface a great advantage in mission design. We are currently testing PNG-GRAND prototypes at a unique outdoor neutron instrumentation test facility recently constructed at NASA/GSFC that consists of a 2 m x 2 in x 1 m granite structure placed outdoors in an empty field. Because an independent trace elemental analysis has been performed on the material, this granite sample is a known standard with which to compare both Monte Carlo simulations and our experimentally measured elemental composition data. We will present data from operating PNG-GRAND in various experimental configurations on a known sample in a geometry that is identical to that on a planetary surface. We will also illustrate the use of gamma ray timing techniques to improve sensitivity and will compare the material composition results from our experiments to both an independent laboratory elemental composition analysis and MCNPX computer modeling results.

  20. Instrumentation at Paranal Observatory: maintaining the instrument suite of five large telescopes and its interferometer alive

    NASA Astrophysics Data System (ADS)

    Gillet, Gordon; Alvarez, José Luis; Beltrán, Juan; Bourget, Pierre; Castillo, Roberto; Diaz, Álvaro; Haddad, Nicolás; Leiva, Alfredo; Mardones, Pedro; O'Neal, Jared; Ribes, Mauricio; Riquelme, Miguel; Robert, Pascal; Rojas, Chester; Valenzuela, Javier

    2010-07-01

    This presentation provides interesting miscellaneous information regarding the instrumentation activities at Paranal Observatory. It introduces the suite of 23 instruments and auxiliary systems that are under the responsibility of the Paranal Instrumentation group, information on the type of instruments, their usage and downtime statistics. The data is based on comprehensive data recorded in the Paranal Night Log System and the Paranal Problem Reporting System whose principles are explained as well. The work organization of the 15 team members around the high number of instruments is laid out, which includes: - Maintaining older instruments with obsolete components - Receiving new instruments and supporting their integration and commissioning - Contributing to future instruments in their developing phase. The assignments of the Instrumentation staff to the actual instruments as well as auxiliary equipment (Laser Guide Star Facility, Mask Manufacturing Unit, Cloud Observation Tool) are explained with respect to responsibility and scheduling issues. The essential activities regarding hardware & software are presented, as well as the technical and organizational developments within the group towards its present and future challenges.

  1. Teaching Students to Be Instrumental in Analysis: Peer-Led Team Learning in the Instrumental Laboratory

    ERIC Educational Resources Information Center

    Williams, Jacob L.; Miller, Martin E.; Avitabile, Brianna C.; Burrow, Dillon L.; Schmittou, Allison N.; Mann, Meagan K.; Hiatt, Leslie A.

    2017-01-01

    Many instrumental analysis students develop limited skills as the course rushes through different instruments to ensure familiarity with as many methodologies as possible. This broad coverage comes at the expense of superficiality of learning and a lack of student confidence and engagement. To mitigate these issues, a peer-led team learning model…

  2. Instrumental Analysis in Environmental Chemistry - Gas Phase Detection Systems

    ERIC Educational Resources Information Center

    Stedman, Donald H.; Meyers, Philip A.

    1974-01-01

    Discusses advances made in chemical analysis instrumentation used in environmental monitoring. This first of two articles is concerned with analytical instrumentation in which detection and dispersion depend ultimately on the properties of gaseous molecules. (JR)

  3. Derivation of Design Loads and Random Vibration specifications for Spacecraft Instruments and Sub-Units

    NASA Astrophysics Data System (ADS)

    Fransen, S.; Yamawaki, T.; Akagi, H.; Eggens, M.; van Baren, C.

    2014-06-01

    After a first estimation based on statistics, the design loads for instruments are generally estimated by coupled spacecraft/instrument sine analysis once an FE-model of the spacecraft is available. When the design loads for the instrument have been derived, the next step in the process is to estimate the random vibration environment at the instrument base and to compute the RMS load at the centre of gravity of the instrument by means of vibro-acoustic analysis. Finally the design loads of the light-weight sub-units of the instrument can be estimated through random vibration analysis at instrument level, taking into account the notches required to protect the instrument interfaces in the hard- mounted random vibration test. This paper presents the aforementioned steps of instrument and sub-units loads derivation in the preliminary design phase of the spacecraft and identifies the problems that may be encountered in terms of design load consistency between low-frequency and high-frequency environments. The SpicA FAR-infrared Instrument (SAFARI) which is currently developed for the Space Infrared Telescope for Cosmology and Astrophysics (SPICA) will be used as a guiding example.

  4. Characterizing the transplanar and in-plane water transport properties of fabrics under different sweat rate: Forced Flow Water Transport Tester

    PubMed Central

    Tang, K. P. M.; Chau, K. H.; Kan, C. W.; Fan, J. T.

    2015-01-01

    The water absorption and transport properties of fabrics are critical to wear comfort, especially for sportswear and protective clothing. A new testing apparatus, namely Forced Flow Water Transport Tester (FFWTT), was developed for characterizing the transplanar and in-plane wicking properties of fabrics based on gravimetric and image analysis technique. The uniqueness of this instrument is that the rate of water supply is adjustable to simulate varying sweat rates with reference to the specific end-use conditions ranging from sitting, walking, running to other strenuous activities. This instrument is versatile in terms of the types of fabrics that can be tested. Twenty four types of fabrics with varying constructions and surface finishes were tested. The results showed that FFWTT was highly sensitive and reproducible in differentiating these fabrics and it suggests that water absorption and transport properties of fabrics are sweat rate-dependent. Additionally, two graphic methods were proposed to map the direction of liquid transport and its relation to skin wetness, which provides easy and direct comparison among different fabrics. Correlation analysis showed that FFWTT results have strong correlation with subjective wetness sensation, implying validity and usefulness of the instrument. PMID:26593699

  5. VIMOS Instrument Control Software Design: an Object Oriented Approach

    NASA Astrophysics Data System (ADS)

    Brau-Nogué, Sylvie; Lucuix, Christian

    2002-12-01

    The Franco-Italian VIMOS instrument is a VIsible imaging Multi-Object Spectrograph with outstanding multiplex capabilities, allowing to take spectra of more than 800 objects simultaneously, or integral field spectroscopy mode in a 54x54 arcsec area. VIMOS is being installed at the Nasmyth focus of the third Unit Telescope of the European Southern Observatory Very Large Telescope (VLT) at Mount Paranal in Chile. This paper will describe the analysis, the design and the implementation of the VIMOS Instrument Control System, using UML notation. Our Control group followed an Object Oriented software process while keeping in mind the ESO VLT standard control concepts. At ESO VLT a complete software library is available. Rather than applying waterfall lifecycle, ICS project used iterative development, a lifecycle consisting of several iterations. Each iteration consisted in : capture and evaluate the requirements, visual modeling for analysis and design, implementation, test, and deployment. Depending of the project phases, iterations focused more or less on specific activity. The result is an object model (the design model), including use-case realizations. An implementation view and a deployment view complement this product. An extract of VIMOS ICS UML model will be presented and some implementation, integration and test issues will be discussed.

  6. Characterizing the transplanar and in-plane water transport properties of fabrics under different sweat rate: Forced Flow Water Transport Tester

    NASA Astrophysics Data System (ADS)

    Tang, K. P. M.; Chau, K. H.; Kan, C. W.; Fan, J. T.

    2015-11-01

    The water absorption and transport properties of fabrics are critical to wear comfort, especially for sportswear and protective clothing. A new testing apparatus, namely Forced Flow Water Transport Tester (FFWTT), was developed for characterizing the transplanar and in-plane wicking properties of fabrics based on gravimetric and image analysis technique. The uniqueness of this instrument is that the rate of water supply is adjustable to simulate varying sweat rates with reference to the specific end-use conditions ranging from sitting, walking, running to other strenuous activities. This instrument is versatile in terms of the types of fabrics that can be tested. Twenty four types of fabrics with varying constructions and surface finishes were tested. The results showed that FFWTT was highly sensitive and reproducible in differentiating these fabrics and it suggests that water absorption and transport properties of fabrics are sweat rate-dependent. Additionally, two graphic methods were proposed to map the direction of liquid transport and its relation to skin wetness, which provides easy and direct comparison among different fabrics. Correlation analysis showed that FFWTT results have strong correlation with subjective wetness sensation, implying validity and usefulness of the instrument.

  7. Characterizing the transplanar and in-plane water transport properties of fabrics under different sweat rate: Forced Flow Water Transport Tester.

    PubMed

    Tang, K P M; Chau, K H; Kan, C W; Fan, J T

    2015-11-23

    The water absorption and transport properties of fabrics are critical to wear comfort, especially for sportswear and protective clothing. A new testing apparatus, namely Forced Flow Water Transport Tester (FFWTT), was developed for characterizing the transplanar and in-plane wicking properties of fabrics based on gravimetric and image analysis technique. The uniqueness of this instrument is that the rate of water supply is adjustable to simulate varying sweat rates with reference to the specific end-use conditions ranging from sitting, walking, running to other strenuous activities. This instrument is versatile in terms of the types of fabrics that can be tested. Twenty four types of fabrics with varying constructions and surface finishes were tested. The results showed that FFWTT was highly sensitive and reproducible in differentiating these fabrics and it suggests that water absorption and transport properties of fabrics are sweat rate-dependent. Additionally, two graphic methods were proposed to map the direction of liquid transport and its relation to skin wetness, which provides easy and direct comparison among different fabrics. Correlation analysis showed that FFWTT results have strong correlation with subjective wetness sensation, implying validity and usefulness of the instrument.

  8. Making Sense of Plant Health

    NASA Technical Reports Server (NTRS)

    2001-01-01

    Ciencia, Inc. created a new device, known as a Portable Photosynthesis Analyzer, or Phase Fluorometer, that provides real-time data about the photochemical efficiency of phytoplankton and other plant forms. The commercial version of this technology is used for photosynthesis research and offers major benefits to the field of life science. This new instrument is the first portable instrument of its kind. Through a license agreement with Ciencia, Oriel Instruments, of Stratford, Connecticut, manufactures and markets the commercial version of the instrument under the name LifeSense.TMLifeSense is a 70 MHz single-frequency fluorometer that offers unrivaled capabilities for fluorescence lifetime sensing and analysis. LifeSense provides information about all varieties of photosynthetic systems. Photosynthesis research contributes important health assessments about the plant, be it phytoplankton or a higher form of plant life. With its unique sensing capabilities, LifeSense furnishes data regarding the yield of a plant's photochemistry, as well as its levels of photosynthetic activity. The user can then gain an extremely accurate estimate of the plant's chlorophyll biomass, primary production rates, and a general overview of the plant's physiological condition.

  9. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    PubMed

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  10. A Comprehensive Approach Towards Optimizing the Xenon Plasma Focused Ion Beam Instrument for Semiconductor Failure Analysis Applications.

    PubMed

    Subramaniam, Srinivas; Huening, Jennifer; Richards, John; Johnson, Kevin

    2017-08-01

    The xenon plasma focused ion beam instrument (PFIB), holds significant promise in expanding the applications of focused ion beams in new technology thrust areas. In this paper, we have explored the operational characteristics of a Tescan FERA3 XMH PFIB instrument with the aim of meeting current and future challenges in the semiconductor industry. A two part approach, with the first part aimed at optimizing the ion column and the second optimizing specimen preparation, has been undertaken. Detailed studies characterizing the ion column, optimizing for high-current/high mill rate activities, have been described to support a better understanding of the PFIB. In addition, a novel single-crystal sacrificial mask method has been developed and implemented for use in the PFIB. Using this combined approach, we have achieved high-quality images with minimal artifacts, while retaining the shorter throughput times of the PFIB. Although the work presented in this paper has been performed on a specific instrument, the authors hope that these studies will provide general insight to direct further improvement of PFIB design and applications.

  11. Solvent extraction of oil-sand components for determination of trace elements by neutron activation analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobs, F.S.; Filby, R.H.

    Instrumental neutron activation analysis was used to measure the concentrations of 30 elements in Athabasca oil sands and oil-sand components. The oil sands were separated into solid residue, bitumen, and fines by Soxhlet extraction with toluene-bitumen extract. The mineral content of the extracted bitumen was dependent on the treatment of the oil sand prior to extraction. The geochemically important and organically associated trace element contents of the bitumen (and asphaltenes) were determined by subtracting the mineral contributions from the total measured concentrations. The method allows analysis of the bitumen without the necessity of ultracentrifugation or membrane filtration, which might removemore » geochemically important components of the bitumen. The method permits classification of trace elements into organic and inorganic combinations.« less

  12. The impact of heavy metals from environmental tobacco smoke on indoor air quality as determined by Compton suppression neutron activation analysis.

    PubMed

    Landsberger, S; Wu, D

    1995-12-01

    The method of instrumental neutron activation analysis (NAA) has been improved for air filter samples in the determination of low level heavy metals in indoor air. By using the techniques of epithermal neutron irradiation in conjunction with Compton suppression, the detection limits of cadmium, arsenic and antimony measurements have been dramatically reduced to 2 ng for Cd, 0.2 ng for As, and 0.03 ng for Sb. The determination of these heavy metals in particulate material generated from cigarette smoking in indoor environments has been conducted. Other elements, Br, Cl, Na, K, Zn were also found at elevated levels.

  13. Image Accumulation in Pixel Detector Gated by Late External Trigger Signal and its Application in Imaging Activation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jakubek, J.; Cejnarova, A.; Platkevic, M.

    Single quantum counting pixel detectors of Medipix type are starting to be used in various radiographic applications. Compared to standard devices for digital imaging (such as CCDs or CMOS sensors) they present significant advantages: direct conversion of radiation to electric signal, energy sensitivity, noiseless image integration, unlimited dynamic range, absolute linearity. In this article we describe usage of the pixel device TimePix for image accumulation gated by late trigger signal. Demonstration of the technique is given on imaging coincidence instrumental neutron activation analysis (Imaging CINAA). This method allows one to determine concentration and distribution of certain preselected element in anmore » inspected sample.« less

  14. Dust analysis on board the Destiny+ mission to 3200 Phaethon

    NASA Astrophysics Data System (ADS)

    Krüger, H.; Kobayashi, M.; Arai, T.; Srama, R.; Sarli, B. V.; Kimura, H.; Moragas-Klostermeyer, G.; Soja, R.; Altobelli, N.; Grün, E.

    2017-09-01

    The Japanese Destiny+ spacecraft will be launched to the active asteroid 3200 Phaethon in 2022. Among the proposed core payload is an in-situ dust instrument based on the Cassini Cosmic Dust Analyzer. We use the ESA Interplanetary Meteoroid Engineering Model (IMEM), to study detection conditions and fluences of interplanetary and interstellar dust with a dust analyzer on board Destiny+.

  15. The State of Teacher Evaluation Reform: State Education Agency Capacity and the Implementation of New Teacher-Evaluation Systems

    ERIC Educational Resources Information Center

    McGuinn, Patrick

    2012-01-01

    The Obama administration's Race to the Top competitive grant program initiated an unprecedented wave of state teacher-evaluation reform across the country. To date, most of the scholarly analysis of this activity has focused on the design of the evaluation instruments or the implementation of the new evaluations by districts and schools. But…

  16. Development of CO2 laser Doppler instrumentation for detection of clear air turbulence, volume 1

    NASA Technical Reports Server (NTRS)

    Harris, C. E.; Jelalian, A. V.

    1979-01-01

    Modification, construction, test and operation of an advanced airborne carbon dioxide laser Doppler system for detecting clear air turbulence are described. The second generation CAT program and those auxiliary activities required to support and verify such a first-of-a-kind system are detailed: aircraft interface; ground and flight verification tests; data analysis; and laboratory examinations.

  17. Qualitative analysis of the contributions of nutritionists to the development of an online instrument for monitoring the food intake of schoolchildren

    USDA-ARS?s Scientific Manuscript database

    The Consumo Alimentar e Atividade Fisica de Escolares (CAAFE) questionnaire is an online research tool that has been developed to enable the self-report of physical activity and diet by Brazilian school children aged 7–10 years. Formative research was conducted with nutritionists during the developm...

  18. Asking Students Their Opinions of the Learning Environment: An Empirical Analysis of Elementary Classroom Climate

    ERIC Educational Resources Information Center

    Kearney, W. Sean; Smith, Page A.; Maika, Sean

    2016-01-01

    There is currently a lack of research into classroom climate as perceived by the students themselves. This article presents a new classroom climate evaluation instrument which is designed to gauge student perceptions of their own level of engagement in academic activities, their relationships with peers, and the level of support they feel from…

  19. Thyroid hormone disrupting activities associated with phthalate esters in water sources from Yangtze River Delta.

    PubMed

    Shi, Wei; Zhang, Feng-Xian; Hu, Guan-Jiu; Hao, Ying-Qun; Zhang, Xiao-Wei; Liu, Hong-Ling; Wei, Si; Wang, Xin-Ru; Giesy, John P; Yu, Hong-Xia

    2012-07-01

    Thyroid hormone disrupting compounds in water sources is a concern. Thyroid hormone (TH) agonist and antagonist activities of water sources from the Yangtze River, Huaihe River, Taihu Lake and ground water in the Yangtze River Delta region were evaluated by use of a TH reporter gene assay based on the green monkey kidney fibroblast (CV-1). While weak TH receptor (TR) agonist potency was observed in only one of 15 water sources, antagonist potency was present in most of the water sources. TR antagonist equivalents could be explained by the presence of dibutyl phthalate (DBP), with concentrations ranging from 2.8×10(1) to 1.6×10(3) μg DBP /L (ATR-EQ(50)s). None of the ground waters exhibited TH agonist potencies while all of the samples from Taihu Lake displayed notable TR antagonist potencies. To identify the responsible thyroid active compounds, instrumental analysis was conducted to measure a list of potential thyroid-disrupting chemicals, including organochlorine (OC) pesticides and phthalate esters. Combining the results of the instrumental analysis with those of the bioassay, DBP was determined to account for 17% to 144% of ATR-EQ(50)s in water sources. Furthermore, ATR-EQ(20-80) ranges for TR antagonist activities indicated that samples from locations WX-1 and WX-2 posed the greatest health concern and the associated uncertainty may warrant further investigation. Copyright © 2011 Elsevier Ltd. All rights reserved.

  20. Development and Psychometric Properties of the Instrumental Activities of Daily Living: Compensation Scale

    PubMed Central

    Schmitter-Edgecombe, Maureen; Parsey, Carolyn; Lamb, Richard

    2014-01-01

    The Instrumental Activities of Daily Living – Compensation (IADL-C) scale was developed to capture early functional difficulties and to quantify compensatory strategy use that may mitigate functional decline in the aging population. The IADL-C was validated in a sample of cognitively healthy older adults (N=184) and individuals with mild cognitive impairment (MCI; N=92) and dementia (N=24). Factor analysis and Rasch item analysis led to the 27-item IADL-C informant questionnaire with four functional domain subscales (money and self-management, home daily living, travel and event memory, and social skills). The subscales demonstrated good internal consistency (Rasch reliability 0.80 to 0.93) and test-retest reliability (Spearman coefficients 0.70 to 0.91). The IADL-C total score and subscales showed convergent validity with other IADL measures, discriminant validity with psychosocial measures, and the ability to discriminate between diagnostic groups. The money and self management subscale showed notable difficulties for individuals with MCI, whereas difficulties with home daily living became more prominent for dementia participants. Compensatory strategy use increased in the MCI group and decreased in the dementia group. PMID:25344901

  1. Research Trend of Physical Skill Science --Towards Elucidation of Physical Skill--

    NASA Astrophysics Data System (ADS)

    Furukawa, Koichi; Ueno, Ken; Ozaki, Tomonobu; Kamisato, Shihoko; Kawamoto, Ryuji; Shibuya, Koji; Shiratori, Naruhiko; Suwa, Masaki; Soga, Masato; Taki, Hirokazu; Fujinami, Tsutomu; Hori, Satoshi; Motomura, Yoichi; Morita, Souhei

    Physical skills and language skills are both fundamental intelligent abilities of human being. In this paper, we focus our attention to such sophisticated physical skills as playing sports and playing instruments and introduce research activities aiming at elucidating and verbalizing them. This research area has been launched recently. We introduce approaches from physical modeling, measurements and data analysis, cognitive science and human interface. We also discuss such issues as skill acquisition and its support systems. Furthermore, we consider a fundamental issue of individual differences occurring in every application of skill elucidation. Finally we introduce several attempts of skill elucidation in the fields of dancing, manufacturing, playing string instruments, sports science and medical care.

  2. Aerial Radiological Measuring System (ARMS): systems, procedures and sensitivity (1976)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyns, P K

    1976-07-01

    This report describes the Aerial Radiological Measuring System (ARMS) designed and operated by EG and G, Inc., for the Energy Research and Development Administration's (ERDA) Division of Operational Safety with the cooperation of the Nuclear Regulatory Commission. Designed to rapidly survey large areas for low-level man-made radiation, the ARMS has also proven extremely useful in locating lost radioactive sources of relatively low activity. The system consists of sodium iodide scintillation detectors, data formatting and recording equipment, positioning equipment, meteorological instruments, direct readout hardware, and data analysis equipment. The instrumentation, operational procedures, data reduction techniques and system sensitivities are described, togethermore » with their applications and sample results.« less

  3. The effect of piezoelectric ultrasonic instrumentation on titanium discs: a microscopy and trace elemental analysis in vitro study.

    PubMed

    Tawse-Smith, A; Atieh, M A; Tompkins, G; Duncan, W J; Reid, M R; Stirling, C H

    2016-08-01

    To evaluate in vitro topographical and composition changes by piezoelectric ultrasonic instrumentation with metallic and plastic tips on machined and moderately roughened titanium surfaces. Twenty machined and moderately roughened laser-marked titanium discs were ultrasonically instrumented with metallic and plastic tips. Surface instrumentation was carried out with controlled pressure for 20 and 30 seconds at two power settings. For each time and power setting, instrumentation was repeated four times with one instrumentation per disc quadrant. Surface topography analysis was performed using scanning electron microscopy (SEM) and confocal laser scanning microscopy (CLSM). Surface roughness measurements were compared between instrumented and non-instrumented surfaces. Surface element composition and rinsing solutions were evaluated using energy-dispersive spectroscopy (EDS) and trace elemental analysis using inductively coupled plasma mass spectrometry (ICPMS), respectively. SEM photomicrographs and CLSM 3D surface plot images of instrumented machined and moderately roughened surfaces demonstrated severe surface topographical alterations with metallic tips and mild to moderate changes for plastic tip instrumented sites. ICPMS analysis of the rinsing solutions identified titanium and other metal traces with the use of metallic tips, and mainly titanium and carbon when plastic tips were used. Surface EDS analysis showed elemental traces of the ultrasonic tips. Ultrasonic instrumentation with metallic or plastic tips created surface topographical and compositional changes. Different changes in surface topography were noted between the surfaces, as the roughness of the machined surfaces increased while the extent of roughness of the moderately roughened surfaces decreased. The clinical relevance of these changes is yet to be determined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Development of TPS flight test and operational instrumentation

    NASA Technical Reports Server (NTRS)

    Carnahan, K. R.; Hartman, G. J.; Neuner, G. J.

    1975-01-01

    Thermal and flow sensor instrumentation was developed for use as an integral part of the space shuttle orbiter reusable thermal protection system. The effort was performed in three tasks: a study to determine the optimum instruments and instrument installations for the space shuttle orbiter RSI and RCC TPS; tests and/or analysis to determine the instrument installations to minimize measurement errors; and analysis using data from the test program for comparison to analytical methods. A detailed review of existing state of the art instrumentation in industry was performed to determine the baseline for the departure of the research effort. From this information, detailed criteria for thermal protection system instrumentation were developed.

  5. The International development of PROQOL-HCV: An instrument to assess the health-related quality of life of patients treated for Hepatitis C virus.

    PubMed

    Armstrong, Andrew Richard; Herrmann, Susan Elizabeth; Chassany, Olivier; Lalanne, Christophe; Da Silva, Mariliza Henrique; Galano, Eliana; Carrieri, Patrizia M; Estellon, Vincent; Sogni, Philippe; Duracinsky, Martin

    2016-08-23

    Hepatitis C virus (HCV) compromises Health-related Quality of Life (HRQL) with detriments to Physical, Mental and Social health domains. Treatment with interferon and ribavirin is associated with side effects which further impair HRQL. New treatments appear potent, effective and tolerable. However, Patient Reported Outcomes instruments that capture the impact on HRQL for people with hepatitis C are largely non-specific and will be needed in the new treatment era. Therefore, we developed a conceptually valid multidimensional model of HCV-specific quality of life and pilot survey instrument, the Patient Reported Outcome Quality of Life survey for HCV (PROQOL-HCV). HCV patients from France (n = 30), Brazil (n = 20) and Australia (n = 20) were interviewed to investigate HCV-HRQL issues raised in the scientific literature and by treatment specialists. Interviews were recorded, transcribed and translated into English and French. Fifteen content dimensions were derived from the qualitative analysis, refined and fitted to four domains: (1) Physical Health included: fatigue, pain, sleep, sexual impairment and physical activity; (2) Mental Health: psychological distress, psychosocial impact, and cognition; (3) Social Health: support, stigma, social activity, substance use; (4) TREATMENT: management, side effects, and fear of treatment failure. The impact of some dimensions extended beyond their primary domain including: physical activity, cognition, sleep, sexual impairment, and the three treatment dimensions. A bank of 300 items was constructed to reflect patient reports and, following expert review, reduced to a 72-item pilot questionnaire. We present a conceptually valid multidimensional model of HCV-specific quality of life and the pilot survey instrument, PROQOL-HCV. The model is widely inclusive of the experience of hepatitis C and the first to include the treatment dimension.

  6. SEM analysis of defects and wear on Ni-Ti rotary instruments.

    PubMed

    Arantes, Werington Borges; da Silva, Celso Monteiro; Lage-Marques, José Luiz; Habitante, Sandramarcia; da Rosa, Luiz Carlos Laureano; de Medeiros, João Marcelo Ferreira

    2014-01-01

    SEM analysis of endodontic instruments from a Ni-Ti rotary system was assessed, before and after using them, considering their defects and deformations. Twenty Twisted File®, BioRąCe®, Mtwo®, and EndoWave® instruments were micrographed at 190× magnification. The files were washed and micrographed again to view alterations as to the presence or absence of irregular edges, grooves, microcavities, and scraping. Simulated root canal preparations were performed using these instruments. The instruments were cleaned and received a microscopic analysis after being used five times. After analysis tests were tested using Fisher's exact test and Kappa to evaluate the concordance among examiners. There was a statistically significant difference with respect to deformations between Twisted File® and other instruments (p < 0.05). There was no statistically significant difference in strains between the other groups (p > 0.05). All Twisted File® instruments showed the same defects; however damage were lower than those found in BioRace® and Mtwo®. The Endowave® did not show the same defects. In accordance with the data we conclude that the presence of defects was higher in Twisted File® instruments as the instruments and BioRace® Mtwo® brand, the defect rate was smaller and Endowave® instruments had no defects. Regarding the presence of wear after five uses among the groups all instruments showed changes in their cutting blades. © 2014 Wiley Periodicals, Inc.

  7. Theoretical and practical considerations for the design of the iMUSH active-source seismic experiment

    NASA Astrophysics Data System (ADS)

    Kiser, E.; Levander, A.; Harder, S. H.; Abers, G. A.; Creager, K. C.; Vidale, J. E.; Moran, S. C.; Malone, S. D.

    2013-12-01

    The multi-disciplinary imaging of Magma Under St. Helens (iMUSH) experiment seeks to understand the details of the magmatic system that feeds Mount St. Helens using active- and passive-source seismic, magnetotelluric, and petrologic data. The active-source seismic component of this experiment will take place in the summer of 2014 utilizing all of the 2600 PASSCAL 'Texan' Reftek instruments which will record twenty-four 1000-2000 lb shots distributed around the Mount St. Helens region. The instruments will be deployed as two consecutive refraction profiles centered on the volcano, and a series of areal arrays. The actual number of areal arrays, as well as their locations, will depend strongly on the length of the experiment (3-4 weeks), the number of instrument deployers (50-60), and the time it will take per deployment given the available road network. The current work shows how we are balancing these practical considerations against theoretical experiment designs in order to achieve the proposed scientific goals with the available resources. One of the main goals of the active-source seismic experiment is to image the magmatic system down to the Moho (35-40 km). Calculating sensitivity kernels for multiple shot/receiver offsets shows that direct P waves should be sensitive to Moho depths at offsets of 150 km, and therefore this will likely be the length of the refraction profiles. Another primary objective of the experiment is to estimate the locations and volumes of different magma accumulation zones beneath the volcano using the areal arrays. With this in mind, the optimal locations of these arrays, as well as their associated shots, are estimated using an eigenvalue analysis of the approximate Hessian for each possible experiment design. This analysis seeks to minimize the number of small eigenvalues of the approximate Hessian that would amplify the propagation of data noise into regions of interest in the model space, such as the likely locations of magma reservoirs. In addition, this analysis provides insight into the tradeoff between the number of areal array deployments and the information that will be gained from the experiment. An additional factor incorporated into this study is the expected data quality in different regions around Mount St. Helens. Expected data quality is determined using the signal-to-noise ratios of data from existing seismometers in the region, and from forward modeling the wavefields from different experiment designs using SPECFEM3D software. In particular, we are interested in evaluating how topography near the volcano and low velocity volcaniclastic layers affect data quality. This information is especially important within 5 km of the volcano where only hiking trails are available for instrument deployment, and in a large area north of the volcano where road maintenance has lagged since the 1980 eruption. Instrument deployment will be slow in these regions, and therefore it is essential to understand if deployment of instruments here is a reasonable use of resources. A final step of this study will be validating different experiment designs based upon the above criteria by inverting synthetic data from velocity models that contain a generalized representation of the magma system to confirm that the main features of the models can be recovered.

  8. Implementation of picoSpin Benchtop NMR Instruments into Organic Chemistry Teaching Laboratories through Spectral Analysis of Fischer Esterification Products

    ERIC Educational Resources Information Center

    Yearty, Kasey L.; Sharp, Joseph T.; Meehan, Emma K.; Wallace, Doyle R.; Jackson, Douglas M.; Morrison, Richard W.

    2017-01-01

    [Superscript 1]H NMR analysis is an important analytical technique presented in introductory organic chemistry courses. NMR instrument access is limited for undergraduate organic chemistry students due to the size of the instrument, price of NMR solvents, and the maintenance level required for instrument upkeep. The University of Georgia Chemistry…

  9. Examination of Children's Recess Physical Activity Patterns Using the Activities for Daily Living-Playground Participation (ADL-PP) Instrument

    ERIC Educational Resources Information Center

    Stellino, Megan Babkes; Sinclair, Christina

    2014-01-01

    Thorough assessment of children's physical activity is essential to efficacious interventions to reduce childhood obesity prevalence. The purpose of this study was to examine children's recess physical activity (RPA) patterns of behavior using the Activities of Daily Living-Playground Participation (ADL-PP: Watkinson et al., 2001) instrument.…

  10. A comparison of two computer-automated semen analysis instruments for the evaluation of sperm motion characteristics in the stallion.

    PubMed

    Jasko, D J; Lein, D H; Foote, R H

    1990-01-01

    Two commercially available computer-automate semen analysis instruments (CellSoft Automated Semen Analyzer and HTM-2000 Motion Analyzer) were compared for their ability to report similar results based on the analysis of pre-recorded video tapes of extended, motile stallion semen. The determinations of the percentage of motile cells by these instruments were more similar than the comparisons between subjective estimates and either instrument. However, mean values obtained from the same sample may still differ by as much as 30 percentage units between instruments. Instruments varied with regard to the determinations of mean sperm curvilinear velocity and sperm concentration, but mean sperm linearity determinations were similar between the instruments. We concluded that the determinations of sperm motion characteristics by subjective estimation, CellSoft Automated Semen Analyzer, and HTM-2000 Motility Analyzer are often dissimilar, making direct comparisons of results difficult.

  11. The development and exploratory analysis of the Back Pain Attitudes Questionnaire (Back-PAQ).

    PubMed

    Darlow, Ben; Perry, Meredith; Mathieson, Fiona; Stanley, James; Melloh, Markus; Marsh, Reginald; Baxter, G David; Dowell, Anthony

    2014-05-23

    To develop an instrument to assess attitudes and underlying beliefs about back pain, and subsequently investigate its internal consistency and underlying structures. The instrument was developed by a multidisciplinary team of clinicians and researchers based on analysis of qualitative interviews with people experiencing acute and chronic back pain. Exploratory analysis was conducted using data from a population-based cross-sectional survey. Qualitative interviews with community-based participants and subsequent postal survey. Instrument development informed by interviews with 12 participants with acute back pain and 11 participants with chronic back pain. Data for exploratory analysis collected from New Zealand residents and citizens aged 18 years and above. 1000 participants were randomly selected from the New Zealand Electoral Roll. 602 valid responses were received. The 34-item Back Pain Attitudes Questionnaire (Back-PAQ) was developed. Internal consistency was evaluated by the Cronbach α coefficient. Exploratory analysis investigated the structure of the data using Principal Component Analysis. The 34-item long form of the scale had acceptable internal consistency (α=0.70; 95% CI 0.66 to 0.73). Exploratory analysis identified five two-item principal components which accounted for 74% of the variance in the reduced data set: 'vulnerability of the back'; 'relationship between back pain and injury'; 'activity participation while experiencing back pain'; 'prognosis of back pain' and 'psychological influences on recovery'. Internal consistency was acceptable for the reduced 10-item scale (α=0.61; 95% CI 0.56 to 0.66) and the identified components (α between 0.50 and 0.78). The 34-item long form of the scale may be appropriate for use in future cross-sectional studies. The 10-item short form may be appropriate for use as a screening tool, or an outcome assessment instrument. Further testing of the 10-item Back-PAQ's construct validity, reliability, responsiveness to change and predictive ability needs to be conducted. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  12. Organizational Member Involvement in Physical Activity Coalitions across the United States: Development and Testing of a Novel Survey Instrument for Assessing Coalition Functioning

    ERIC Educational Resources Information Center

    Bornstein, Daniel B.; Pate, Russell R.; Beets, Michael W.; Saunders, Ruth P.; Blair, Steven N.

    2015-01-01

    Introduction: Coalitions are often composed of member organizations. Member involvement is thought to be associated with coalition success. No instrument currently exists for evaluating organizational member involvement in physical activity coalitions. This study aimed to develop a survey instrument for evaluating organizational member involvement…

  13. Validity and reliability of a self-report instrument to assess social support and physical environmental correlates of physical activity in adolescents

    PubMed Central

    2012-01-01

    Background The purpose of this study was to examine the internal consistency, test-retest reliability, construct validity and predictive validity of a new German self-report instrument to assess the influence of social support and the physical environment on physical activity in adolescents. Methods Based on theoretical consideration, the short scales on social support and physical environment were developed and cross-validated in two independent study samples of 9 to 17 year-old girls and boys. The longitudinal sample of Study I (n = 196) was recruited from a German comprehensive school, and subjects in this study completed the questionnaire twice with a between-test interval of seven days. Cronbach’s alphas were computed to determine the internal consistency of the factors. Test-retest reliability of the latent factors was assessed using intra-class coefficients. Factorial validity of the scales was assessed using principle components analysis. Construct validity was determined using a cross-validation technique by performing confirmatory factor analysis with the independent nationwide cross-sectional sample of Study II (n = 430). Correlations between factors and three measures of physical activity (objectively measured moderate-to-vigorous physical activity (MVPA), self-reported habitual MVPA and self-reported recent MVPA) were calculated to determine the predictive validity of the instrument. Results Construct validity of the social support scale (two factors: parental support and peer support) and the physical environment scale (four factors: convenience, public recreation facilities, safety and private sport providers) was shown. Both scales had moderate test-retest reliability. The factors of the social support scale also had good internal consistency and predictive validity. Internal consistency and predictive validity of the physical environment scale were low to acceptable. Conclusions The results of this study indicate moderate to good reliability and construct validity of the social support scale and physical environment scale. Predictive validity was only confirmed for the social support scale but not for the physical environment scale. Hence, it remains unclear if a person’s physical environment has a direct or an indirect effect on physical activity behavior or a moderation function. PMID:22928865

  14. Validity and reliability of a self-report instrument to assess social support and physical environmental correlates of physical activity in adolescents.

    PubMed

    Reimers, Anne K; Jekauc, Darko; Mess, Filip; Mewes, Nadine; Woll, Alexander

    2012-08-29

    The purpose of this study was to examine the internal consistency, test-retest reliability, construct validity and predictive validity of a new German self-report instrument to assess the influence of social support and the physical environment on physical activity in adolescents. Based on theoretical consideration, the short scales on social support and physical environment were developed and cross-validated in two independent study samples of 9 to 17 year-old girls and boys. The longitudinal sample of Study I (n = 196) was recruited from a German comprehensive school, and subjects in this study completed the questionnaire twice with a between-test interval of seven days. Cronbach's alphas were computed to determine the internal consistency of the factors. Test-retest reliability of the latent factors was assessed using intra-class coefficients. Factorial validity of the scales was assessed using principle components analysis. Construct validity was determined using a cross-validation technique by performing confirmatory factor analysis with the independent nationwide cross-sectional sample of Study II (n = 430). Correlations between factors and three measures of physical activity (objectively measured moderate-to-vigorous physical activity (MVPA), self-reported habitual MVPA and self-reported recent MVPA) were calculated to determine the predictive validity of the instrument. Construct validity of the social support scale (two factors: parental support and peer support) and the physical environment scale (four factors: convenience, public recreation facilities, safety and private sport providers) was shown. Both scales had moderate test-retest reliability. The factors of the social support scale also had good internal consistency and predictive validity. Internal consistency and predictive validity of the physical environment scale were low to acceptable. The results of this study indicate moderate to good reliability and construct validity of the social support scale and physical environment scale. Predictive validity was only confirmed for the social support scale but not for the physical environment scale. Hence, it remains unclear if a person's physical environment has a direct or an indirect effect on physical activity behavior or a moderation function.

  15. Influence of Cyclic Flexural Deformation on the Torsional Resistance of Controlled Memory and Conventional Nickel-titanium Instruments.

    PubMed

    Acosta, Eufemia Carolina Peláez; Resende, Pedro Damas; Peixoto, Isabella Faria da Cunha; Pereira, Érika Sales Joviano; Buono, Vicente Tadeu Lopes; Bahia, Maria Guiomar de Azevedo

    2017-04-01

    The aim of this study was to evaluate the influence of cyclic deformation on the torsional resistance of controlled memory (CM) nickel-titanium files in comparison with superelastic (SE) instruments with similar geometric and dimensional characteristics. New 30/.06 HyFlex (HF; Coltene/Whaledent, Inc, Cuyahoga Falls, OH), Typhoon (Clinician's Choice Dental Products, New Milford, CT), RaCe (FKG, La-Chaux De Fonds, Switzerland), and ProTaper Universal F2 instruments (F2; Dentsply Maillefer, Ballaigues, Switzerland) were assessed. The diameter and pitch length were measured along the active part of the instruments. The number of cycles to failure (Nf) in flexural fatigue and the torsional resistance were evaluated for new files (n = 10). Ten new instruments of each type were fatigued to 3/4 of their fatigue life and then submitted to torsion until rupture. Data were analyzed using 1-way analysis of variance (α = .05). New CM files had a significantly higher Nf when compared with SE instruments; HF exhibited the highest value (P = .001). The mean torque value for F2 was the highest (P = .001). CM files precycled to 3/4 Nf had a significantly lower torque than the new files (HF: P = .003, Typhoon: P = .001), whereas the SE instruments displayed no significant differences (F2: P = .059, RaCe: P = .079). Cyclic flexural loading significantly reduced the torsional resistance of CM instruments. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Workshop on Analysis of Returned Comet Nucleus Samples

    NASA Technical Reports Server (NTRS)

    1989-01-01

    This volume contains abstracts that were accepted by the Program Committee for presentation at the workshop on the analysis of returned comet nucleus samples held in Milpitas, California, January 16 to 18, 1989. The abstracts deal with the nature of cometary ices, cryogenic handling and sampling equipment, origin and composition of samples, and spectroscopic, thermal and chemical processing methods of cometary nuclei. Laboratory simulation experimental results on dust samples are reported. Some results obtained from Halley's comet are also included. Microanalytic techniques for examining trace elements of cometary particles, synchrotron x ray fluorescence and instrument neutron activation analysis (INAA), are presented.

  17. Computer graphics for quality control in the INAA of geological samples

    USGS Publications Warehouse

    Grossman, J.N.; Baedecker, P.A.

    1987-01-01

    A data reduction system for the routine instrumental activation analysis of samples is described, with particular emphasis on interactive graphics capabilities for evaluating analytical quality. Graphics procedures have been developed to interactively control the analysis of selected photopeaks during spectral analysis, and to evaluate detector performance during a given counting cycle. Graphics algorithms are also used to compare the data on reference samples with accepted values, to prepare quality control charts to evaluate long term precision and to search for systematic variations in data on reference samples as a function of time. ?? 1987 Akade??miai Kiado??.

  18. An ergonomic analysis of work in the process of professional rehabilitation in Brazil.

    PubMed

    Cabral, A; Souza e Silva, M; Louzada, E; Cesar, W

    2012-01-01

    The purpose of this study is to describe the use of the Ergonomic Analysis of Work (EAW) in the process of rehabilitating workers, insured by the National Institute of Social Security (INSS) in Brazil, and to conduct a brief analysis of the instrument used by this body. Information obtained from EAW enabled the demand, the requirements of the activity and the skills needed to perform the tasks in the workplace to be determined, thus aiding the decision of the INSS as to rehabilitating the workers and their return to their jobs.

  19. Performance analysis of the ascent propulsion system of the Apollo spacecraft

    NASA Technical Reports Server (NTRS)

    Hooper, J. C., III

    1973-01-01

    Activities involved in the performance analysis of the Apollo lunar module ascent propulsion system are discussed. A description of the ascent propulsion system, including hardware, instrumentation, and system characteristics, is included. The methods used to predict the inflight performance and to establish performance uncertainties of the ascent propulsion system are discussed. The techniques of processing the telemetered flight data and performing postflight performance reconstruction to determine actual inflight performance are discussed. Problems that have been encountered and results from the analysis of the ascent propulsion system performance during the Apollo 9, 10, and 11 missions are presented.

  20. A MATLAB-based graphical user interface for the identification of muscular activations from surface electromyography signals.

    PubMed

    Mengarelli, Alessandro; Cardarelli, Stefano; Verdini, Federica; Burattini, Laura; Fioretti, Sandro; Di Nardo, Francesco

    2016-08-01

    In this paper a graphical user interface (GUI) built in MATLAB® environment is presented. This interactive tool has been developed for the analysis of superficial electromyography (sEMG) signals and in particular for the assessment of the muscle activation time intervals. After the signal import, the tool performs a first analysis in a totally user independent way, providing a reliable computation of the muscular activation sequences. Furthermore, the user has the opportunity to modify each parameter of the on/off identification algorithm implemented in the presented tool. The presence of an user-friendly GUI allows the immediate evaluation of the effects that the modification of every single parameter has on the activation intervals recognition, through the real-time updating and visualization of the muscular activation/deactivation sequences. The possibility to accept the initial signal analysis or to modify the on/off identification with respect to each considered signal, with a real-time visual feedback, makes this GUI-based tool a valuable instrument in clinical, research applications and also in an educational perspective.

  1. Nurses' Attitudes Regarding the Safe Handling of Patients Who Are Morbidly Obese: Instrument Development and Psychometric Analysis.

    PubMed

    Bejciy-Spring, Susan; Vermillion, Brenda; Morgan, Sally; Newton, Cheryl; Chucta, Sheila; Gatens, Cindy; Zadvinskis, Inga; Holloman, Christopher; Chipps, Esther

    2016-12-01

    Nurses' attitudes play an important role in the consistent practice of safe patient handling behaviors. The purposes of this study were to develop and assess the psychometric properties of a newly developed instrument measuring attitudes of nurses related to the care and safe handling of patients who are obese. Phases of instrument development included (a) item generation, (b) content validity assessment, (c) reliability assessment, (d) cognitive interviewing, and (e) construct validity assessment through factor analysis. The final data from the exploratory factor analysis produced a 26-item multidimensional instrument that contains 9 subscales. Based on the factor analysis, a 26-item instrument can be used to examine nurses' attitudes regarding patients who are morbidly obese and related safe handling practices.

  2. Traceability of radiation protection instruments

    NASA Astrophysics Data System (ADS)

    Hino, Y.; Kurosawa, T.

    2007-08-01

    Radiation protection instruments are used in daily measurement of dose and activities in workplaces and environments for safety management. The requirements for calibration certificates with traceability are increasing for these instruments to ensure the consistency and reliabilities of the measurement results. The present traceability scheme of radiation protection instruments for dose and activity measurements is described with related IEC/ISO requirements. Some examples of desirable future calibration systems with recent new technologies are also discussed to establish the traceability with reasonable costs and reliabilities.

  3. Psychometric Properties of Physical Activity and Leisure Motivation Scale in Farsi: an International Collaborative Project on Motivation for Physical Activity and Leisure.

    PubMed

    Zarei, Sahar; Memari, Amir-Hossein; Moshayedi, Pouria; Mosayebi, Fatolla; Mansournia, Mohammad Ali; Khoo, Selina; Morris, Tony

    2016-10-01

    Given the importance of regular physical activity, it is crucial to evaluate the factors favoring participation in physical activity. We aimed to report the psychometric analysis of the Farsi version of the Physical Activity and Leisure Motivation Scale (PALMS). The Farsi version of PALMS was completed by 406 healthy adult individuals to test its factor structure and concurrent validity and reliability. Conducting the exploratory factor analysis revealed nine factors that accounted for 64.6% of the variances. The PALMS reliability was supported with a high internal consistency of 0.91 and a high test-retest reliability of 0.97 (95% CI: 0.97-0.98). The association between the PALMS and its previous version Recreational Exercise Motivation Measure scores was strongly significant (r= 0.86, P < 0.001). We have shown that the Farsi version of the PALMS appears to be a valuable instrument to measure motivation for physical activity and leisure.

  4. Exploratory factor analysis of the Research and Development Culture Index among qualified nurses.

    PubMed

    Watson, Bill; Clarke, Charlotte; Swallow, Vera; Forster, Stewart

    2005-10-01

    This paper presents the exploratory factor analysis of a rating instrument for assessing the strength of organizational Research and Development (R&D) culture. Despite nursing's limited research capacity, the discipline is capitalizing upon opportunities to become involved in research and is making strong progress. Within the context of the debate on nursing research capacity, the R&D Culture Index was developed as a means of appraising R&D culture within health care organizations. Factor analysis was carried out on data collected from 485 nursing staff. The method of extraction was Principal Components Analysis with oblique rotation. The Index was developed from the findings of qualitative research conducted with NHS staff. Eighteen items, encompassing the main themes from the data, were initially included in the Index. This pilot instrument was distributed to nursing staff within three different types of NHS Trust. Factor analysis resulted in rejection of two items and the analysis was repeated using the remaining 16 items. Three latent factors were extracted accounting for 58.0% of the variance in the data. The factors were: R&D Support, describing the perceived support within the working environment for R&D activity; Personal R&D Skills and Aptitude, describing an individual's perception of their ability towards R&D activity; and Personal R&D Intention, describing an individual's willingness to engage in R&D activity. Each factor had good internal reliability, as did the overall index. The R&D Culture Index provides an efficient means of assessing the strength of an organization's R&D culture in a way that captures the role of the individual practitioner and the organizational environment. These findings suggest that the continuing promotion of R&D within health care organizations is dependent upon a multi-faceted approach that addresses the learning needs of the organization as well as those of the individual practitioners.

  5. Assessing Causality in the Association between Child Adiposity and Physical Activity Levels: A Mendelian Randomization Analysis

    PubMed Central

    Richmond, Rebecca C.; Davey Smith, George; Ness, Andy R.; den Hoed, Marcel; McMahon, George; Timpson, Nicholas J.

    2014-01-01

    Background Cross-sectional studies have shown that objectively measured physical activity is associated with childhood adiposity, and a strong inverse dose–response association with body mass index (BMI) has been found. However, few studies have explored the extent to which this association reflects reverse causation. We aimed to determine whether childhood adiposity causally influences levels of physical activity using genetic variants reliably associated with adiposity to estimate causal effects. Methods and Findings The Avon Longitudinal Study of Parents and Children collected data on objectively assessed activity levels of 4,296 children at age 11 y with recorded BMI and genotypic data. We used 32 established genetic correlates of BMI combined in a weighted allelic score as an instrumental variable for adiposity to estimate the causal effect of adiposity on activity. In observational analysis, a 3.3 kg/m2 (one standard deviation) higher BMI was associated with 22.3 (95% CI, 17.0, 27.6) movement counts/min less total physical activity (p = 1.6×10−16), 2.6 (2.1, 3.1) min/d less moderate-to-vigorous-intensity activity (p = 3.7×10−29), and 3.5 (1.5, 5.5) min/d more sedentary time (p = 5.0×10−4). In Mendelian randomization analyses, the same difference in BMI was associated with 32.4 (0.9, 63.9) movement counts/min less total physical activity (p = 0.04) (∼5.3% of the mean counts/minute), 2.8 (0.1, 5.5) min/d less moderate-to-vigorous-intensity activity (p = 0.04), and 13.2 (1.3, 25.2) min/d more sedentary time (p = 0.03). There was no strong evidence for a difference between variable estimates from observational estimates. Similar results were obtained using fat mass index. Low power and poor instrumentation of activity limited causal analysis of the influence of physical activity on BMI. Conclusions Our results suggest that increased adiposity causes a reduction in physical activity in children and support research into the targeting of BMI in efforts to increase childhood activity levels. Importantly, this does not exclude lower physical activity also leading to increased adiposity, i.e., bidirectional causation. Please see later in the article for the Editors' Summary PMID:24642734

  6. The roles of lesson study in the development of mathematics learning instrument based on learning trajectory

    NASA Astrophysics Data System (ADS)

    Misnasanti; Dien, C. A.; Azizah, F.

    2018-03-01

    This study is aimed to describe Lesson Study (LS) activity and its roles in the development of mathematics learning instruments based on Learning Trajectory (LT). This study is a narrative study of teacher’s experiences in joining LS activity. Data collecting in this study will use three methods such as observation, documentations, and deep interview. The collected data will be analyzed with Milles and Huberman’s model that consists of reduction, display, and verification. The study result shows that through LS activity, teachers know more about how students think. Teachers also can revise their mathematics learning instrument in the form of lesson plan. It means that LS activity is important to make a better learning instruments and focus on how student learn not on how teacher teach.

  7. Review of 99 self-report measures for assessing well-being in adults: exploring dimensions of well-being and developments over time

    PubMed Central

    Dieppe, Paul

    2016-01-01

    Objective Investigators within many disciplines are using measures of well-being, but it is not always clear what they are measuring, or which instruments may best meet their objectives. The aims of this review were to: systematically identify well-being instruments, explore the variety of well-being dimensions within instruments and describe how the production of instruments has developed over time. Design Systematic searches, thematic analysis and narrative synthesis were undertaken. Data sources MEDLINE, EMBASE, EconLit, PsycINFO, Cochrane Library and CINAHL from 1993 to 2014 complemented by web searches and expert consultations through 2015. Eligibility criteria Instruments were selected for review if they were designed for adults (≥18 years old), generic (ie, non-disease or context specific) and available in an English version. Results A total of 99 measures of well-being were included, and 196 dimensions of well-being were identified within them. Dimensions clustered around 6 key thematic domains: mental well-being, social well-being, physical well-being, spiritual well-being, activities and functioning, and personal circumstances. Authors were rarely explicit about how existing theories had influenced the design of their tools; however, the 2 most referenced theories were Diener's model of subjective well-being and the WHO definition of health. The period between 1990 and 1999 produced the greatest number of newly developed well-being instruments (n=27). An illustration of the dimensions identified and the instruments that measure them is provided within a thematic framework of well-being. Conclusions This review provides researchers with an organised toolkit of instruments, dimensions and an accompanying glossary. The striking variability between instruments supports the need to pay close attention to what is being assessed under the umbrella of ‘well-being’ measurement. PMID:27388349

  8. Determination of minor and trace elements in kidney stones by x-ray fluorescence analysis

    NASA Astrophysics Data System (ADS)

    Srivastava, Anjali; Heisinger, Brianne J.; Sinha, Vaibhav; Lee, Hyong-Koo; Liu, Xin; Qu, Mingliang; Duan, Xinhui; Leng, Shuai; McCollough, Cynthia H.

    2014-03-01

    The determination of accurate material composition of a kidney stone is crucial for understanding the formation of the kidney stone as well as for preventive therapeutic strategies. Radiations probing instrumental activation analysis techniques are excellent tools for identification of involved materials present in the kidney stone. In particular, x-ray fluorescence (XRF) can be very useful for the determination of minor and trace materials in the kidney stone. The X-ray fluorescence measurements were performed at the Radiation Measurements and Spectroscopy Laboratory (RMSL) of department of nuclear engineering of Missouri University of Science and Technology and different kidney stones were acquired from the Mayo Clinic, Rochester, Minnesota. Presently, experimental studies in conjunction with analytical techniques were used to determine the exact composition of the kidney stone. A new type of experimental set-up was developed and utilized for XRF analysis of the kidney stone. The correlation of applied radiation source intensity, emission of X-ray spectrum from involving elements and absorption coefficient characteristics were analyzed. To verify the experimental results with analytical calculation, several sets of kidney stones were analyzed using XRF technique. The elements which were identified from this techniques are Silver (Ag), Arsenic (As), Bromine (Br), Chromium (Cr), Copper (Cu), Gallium (Ga), Germanium (Ge), Molybdenum (Mo), Niobium (Nb), Rubidium (Rb), Selenium (Se), Strontium (Sr), Yttrium (Y), Zirconium (Zr). This paper presents a new approach for exact detection of accurate material composition of kidney stone materials using XRF instrumental activation analysis technique.

  9. Multidimensional Predictors of Fatigue among Octogenarians and Centenarians

    PubMed Central

    Cho, Jinmyoung; Martin, Peter; Margrett, Jennifer; MacDonald, Maurice; Johnson, Mary Ann; Poon, Leonard W.

    2012-01-01

    Background Fatigue is a common and frequently observed complaint among older adults. However, knowledge about the nature and correlates of fatigue in old age is very limited. Objective: This study examined the relationship of functional indicators, psychological and situational factors and fatigue for 210 octogenarians and centenarians from the Georgia Centenarian Study. Methods Three indicators of functional capacity (self-rated health, instrumental activities of daily living, physical activities of daily living), two indicators of psychological well-being (positive and negative affect), two indicators of situational factors (social network and social support), and a multidimensional fatigue scale were used. Blocked multiple regression analyses were computed to examine significant factors related to fatigue. In addition, multi-group analysis in structural equation modeling was used to investigate residential differences (i.e., long-term care facilities vs. private homes) in the relationship between significant factors and fatigue. Results Blocked multiple regression analyses indicated that two indicators of functional capacity, self-rated health and instrumental activities of daily living, both positive and negative affect, and social support were significant predictors of fatigue among oldest-old adults. The multiple group analysis in structural equation modeling revealed a significant difference among oldest-old adults based on residential status. Conclusion The results suggest that we should not consider fatigue as merely an unpleasant physical symptom, but rather adopt a perspective that different factors such as psychosocial aspects can influence fatigue in advanced later life. PMID:22094445

  10. Multidimensional predictors of fatigue among octogenarians and centenarians.

    PubMed

    Cho, Jinmyoung; Martin, Peter; Margrett, Jennifer; MacDonald, Maurice; Johnson, Mary Ann; Poon, Leonard W; Jazwinski, S M; Green, R C; Gearing, M; Woodard, J L; Tenover, J S; Siegler, I C; Rott, C; Rodgers, W L; Hausman, D; Arnold, J; Davey, A

    2012-01-01

    Fatigue is a common and frequently observed complaint among older adults. However, knowledge about the nature and correlates of fatigue in old age is very limited. This study examined the relationship of functional indicators, psychological and situational factors and fatigue for 210 octogenarians and centenarians from the Georgia Centenarian Study. Three indicators of functional capacity (self-rated health, instrumental activities of daily living, physical activities of daily living), two indicators of psychological well-being (positive and negative affect), two indicators of situational factors (social network and social support), and a multidimensional fatigue scale were used. Blocked multiple regression analyses were computed to examine significant factors related to fatigue. In addition, multi-group analysis in structural equation modeling was used to investigate residential differences (i.e., long-term care facilities vs. private homes) in the relationship between significant factors and fatigue. Blocked multiple regression analyses indicated that two indicators of functional capacity, self-rated health and instrumental activities of daily living, both positive and negative affect, and social support were significant predictors of fatigue among oldest-old adults. The multiple group analysis in structural equation modeling revealed a significant difference among oldest-old adults based on residential status. The results suggest that we should not consider fatigue as merely an unpleasant physical symptom, but rather adopt a perspective that different factors such as psychosocial aspects can influence fatigue in advanced later life. Copyright © 2011 S. Karger AG, Basel.

  11. Development of a new occupational balance-questionnaire: incorporating the perspectives of patients and healthy people in the design of a self-reported occupational balance outcome instrument.

    PubMed

    Dür, Mona; Steiner, Günter; Fialka-Moser, Veronika; Kautzky-Willer, Alexandra; Dejaco, Clemens; Prodinger, Birgit; Stoffer, Michaela Alexandra; Binder, Alexa; Smolen, Josef; Stamm, Tanja Alexandra

    2014-04-05

    Self-reported outcome instruments in health research have become increasingly important over the last decades. Occupational therapy interventions often focus on occupational balance. However, instruments to measure occupational balance are scarce. The aim of the study was therefore to develop a generic self-reported outcome instrument to assess occupational balance based on the experiences of patients and healthy people including an examination of its psychometric properties. We conducted a qualitative analysis of the life stories of 90 people with and without chronic autoimmune diseases to identify components of occupational balance. Based on these components, the Occupational Balance-Questionnaire (OB-Quest) was developed. Construct validity and internal consistency of the OB-Quest were examined in quantitative data. We used Rasch analyses to determine overall fit of the items to the Rasch model, person separation index and potential differential item functioning. Dimensionality testing was conducted by the use of t-tests and Cronbach's alpha. The following components emerged from the qualitative analyses: challenging and relaxing activities, activities with acknowledgement by the individual and by the sociocultural context, impact of health condition on activities, involvement in stressful activities and fewer stressing activities, rest and sleep, variety of activities, adaptation of activities according to changed living conditions and activities intended to care for oneself and for others. Based on these, the seven items of the questionnaire (OB-Quest) were developed. 251 people (132 with rheumatoid arthritis, 43 with systematic lupus erythematous and 76 healthy) filled in the OB-Quest. Dimensionality testing indicated multidimensionality of the questionnaire (t = 0.58, and 1.66 after item reduction, non-significant). The item on the component rest and sleep showed differential item functioning (health condition and age). Person separation index was 0.51. Cronbach's alpha changed from 0.38 to 0.57 after deleting two items. This questionnaire includes new items addressing components of occupational balance meaningful to patients and healthy people which have not been measured so far. The reduction of two items of the OB-Quest showed improved internal consistency. The multidimensionality of the questionnaire indicates the need for a summary of several components into subscales.

  12. Development of a new occupational balance-questionnaire: incorporating the perspectives of patients and healthy people in the design of a self-reported occupational balance outcome instrument

    PubMed Central

    2014-01-01

    Background Self-reported outcome instruments in health research have become increasingly important over the last decades. Occupational therapy interventions often focus on occupational balance. However, instruments to measure occupational balance are scarce. The aim of the study was therefore to develop a generic self-reported outcome instrument to assess occupational balance based on the experiences of patients and healthy people including an examination of its psychometric properties. Methods We conducted a qualitative analysis of the life stories of 90 people with and without chronic autoimmune diseases to identify components of occupational balance. Based on these components, the Occupational Balance-Questionnaire (OB-Quest) was developed. Construct validity and internal consistency of the OB-Quest were examined in quantitative data. We used Rasch analyses to determine overall fit of the items to the Rasch model, person separation index and potential differential item functioning. Dimensionality testing was conducted by the use of t-tests and Cronbach’s alpha. Results The following components emerged from the qualitative analyses: challenging and relaxing activities, activities with acknowledgement by the individual and by the sociocultural context, impact of health condition on activities, involvement in stressful activities and fewer stressing activities, rest and sleep, variety of activities, adaptation of activities according to changed living conditions and activities intended to care for oneself and for others. Based on these, the seven items of the questionnaire (OB-Quest) were developed. 251 people (132 with rheumatoid arthritis, 43 with systematic lupus erythematous and 76 healthy) filled in the OB-Quest. Dimensionality testing indicated multidimensionality of the questionnaire (t = 0.58, and 1.66 after item reduction, non-significant). The item on the component rest and sleep showed differential item functioning (health condition and age). Person separation index was 0.51. Cronbach’s alpha changed from 0.38 to 0.57 after deleting two items. Conclusions This questionnaire includes new items addressing components of occupational balance meaningful to patients and healthy people which have not been measured so far. The reduction of two items of the OB-Quest showed improved internal consistency. The multidimensionality of the questionnaire indicates the need for a summary of several components into subscales. PMID:24708642

  13. Development and testing of a short physical activity recall questionnaire.

    PubMed

    Matthews, Charles E; Ainsworth, Barbara E; Hanby, Cara; Pate, Russell R; Addy, Cheryl; Freedson, Patty S; Jones, Deborah Arriaza; Macera, Caroline A

    2005-06-01

    To develop and test two different short telephone activity recall (STAR) questionnaires, one with closed-ended and the other with open-ended response options, that assessed overall moderate and vigorous activity in a usual week. One hundred four participants completed a 3-d test-retest study, and 88 participants completed 10-14, 24-h physical activity recalls (24PAR) and at least 7 d of objective physical activity monitoring by Actigraph during a 28-d period. Consistency of classification from one administration to the next was high (65-92%), extreme inconsistencies between reports were infrequent (0-7%), and kappa values were between 0.50 and 0.75. Correlations between self-reports and criterion measures for moderate-intensity duration were between 0.30 and 0.40. Agreement between the instruments and the 24PAR for meeting the moderate or vigorous recommendations was between 60 and 70%. For the 24PAR comparisons, kappa values tended to be higher for women than men, but were of only modest strength (kappa 0.40). With the 24PAR as criterion, sensitivity of the self-report instruments was between 50 and 90%, and specificity was between 63 and 84%. Kappa values comparing the instruments with the Actigraph were low (<0.20). Overall classification by the short instruments into meeting the recommendations was associated with higher levels of total 24PAR activity (P < or = 0.01) as well as greater steps per day and counts per minute per day from the Actigraph (P < or = 0.08). The open-ended instrument appeared to perform better for moderate-intensity activity, whereas the closed-ended item appeared to perform better for vigorous activity. The evaluated instruments had reasonable reliability and demonstrated an ability to capture important differences in overall physical activity patterns in this population, although individual classification errors were substantial.

  14. The Use of ATR-FTIR in Conjunction with Thermal Analysis Methods for Efficient Identification of Polymer Samples: A Qualitative Multiinstrument Instrumental Analysis Laboratory Experiment

    ERIC Educational Resources Information Center

    Dickson-Karn, Nicole M.

    2017-01-01

    A multi-instrument approach has been applied to the efficient identification of polymers in an upper-division undergraduate instrumental analysis laboratory course. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) is used in conjunction with differential scanning calorimetry (DSC) to identify 18 polymer samples and…

  15. The Pool Activity Level (PAL) Instrument for Occupational Profiling Jackie Pool The Pool Activity Level (PAL) Instrument for Occupational Profiling Second edition Jessica Kingsley Publishers 96pp £22.50 1843100800 1843100800.

    PubMed

    2002-11-01

    This easy-to-access introduction and workbook to cover the use of the Pool Activity Instrument is a useful addition to the growing resources available under the umbrella of the Bradford Dementia Group. In this second edition, it has been modified to account for suggestions from the field and this shows from its clear and practice-based approach.

  16. BIRA-IASB Mars activities and instrument capabilities

    NASA Astrophysics Data System (ADS)

    Drummond, R.; Vandaele, A.-C.; Gillotay, D.; Willame, Y.; Depiesse, C.; Patel, M.; Daerden, F.; Neefs, E.; Ristic, B.; Montmessin, F.

    2009-04-01

    The Belgian Institute of Space Aeronomy (BIRA-IASB) is involved in many areas of Mars exploration, and has been for a long time. Current activities include analysis of SPICAM data, 3D atmospheric modelling as well as instrument development and characterization. This paper will focus on two different instruments to study the Martian atmosphere. UVIS(Patel, 2006) is part of the Exomars payload, that will gather information on the UV levels on the ground, study climatology and sterilisation and also be able to detect organic material in sublimating permafrost. BIRA-IASB is carrying out the characterization and calibration of UVIS. SOIR is an infra-red spectrometer that uses solar occultation measurements to examine major and minor constituents of planetary atmospheres. SOIR is currently orbiting Venus on the VEX spacecraft and has already made several interesting discoveries including the first observations of a new band of a CO2 isotopologue. The data from SOIR-VEX has allowed us to study the instrumental characteristics and perform a sensitivity study(Mahieux, 2008). These properties have been used to simulate realistic SOIR measurements of Mars atmospheric spectra. This work is supported by extensive 3D chemistry modeling work, as described in a paper by Frank Daerden (PS2.9Atmospheres of terrestrial planets). M. R. Patel, et al.,(2006) The UV-VIS spectrometer for the ExoMars mission, in 36th COSPAR Scientific Assembly, Beijing, China. A. Mahieux, et al.,(2008), Appl. Opt. 47 (13), 2252-65.

  17. Europlanet Research Infrastructure: Planetary Sample Analysis Facilities

    NASA Astrophysics Data System (ADS)

    Cloquet, C.; Mason, N. J.; Davies, G. R.; Marty, B.

    2008-09-01

    EuroPlanet The Europlanet Research Infrastructure consortium funded under FP7 aims to provide the EU Planetary Science community greater access for to research infrastructure. A series of networking and outreach initiatives will be complimented by joint research activities and the formation of three Trans National Access distributed service laboratories (TNA's) to provide a unique and comprehensive set of analogue field sites, laboratory simulation facilities, and extraterrestrial sample analysis tools. Here we report on the infrastructure that comprises the third TNA: Planetary Sample Analysis Facilities. The modular infrastructure represents a major commitment of analytical instrumentation by three institutes and together forms a state-of-the-art analytical facility of unprecedented breadth. These centres perform research in the fields of geochemistry and cosmochemistry, studying fluids and rocks in order to better understand the keys cof the universe. Europlanet Research Infrastructure Facilities: Ion Probe facilities at CRPG and OU The Cameca 1270 Ion microprobe is a CNRS-INSU national facility. About a third of the useful analytical time of the ion probe (about 3 months each year) is allocated to the national community. French scientists have to submit their projects to a national committee for selection. The selected projects are allocated time in the following 6 months twice a year. About 15 to 20 projects are run each year. There are only two such instruments in Europe, with cosmochemistry only performed at CRPG. Different analyses can be performed on a routine basis, such as U-Pb dating on Zircon, Monazite or Pechblende, Li, B, C, O, Si isotopic ratios determination on different matrix, 26Al, 60Fe extinct radioactivity ages, light and trace elements contents . The NanoSIMS 50L - producing element or isotope maps with a spatial resolution down to ≈50nm. This is one of the cornerstone facilities of UKCAN, with 75% of available instrument time funded and committed to UK cosmochemical activity - but the remainder is free for other applications and users. The UK activity is managed by the UKCAN management committee and vetted through a local working group. Management of the remaining 25% of other activity will be organised through the local working group. This is the newest, and most advanced of three instruments of this type in Europe which routinely address cosmochemical analyses. The instrument is capable of providing high spatial resolution (down to 50nm) elemental and isotope distribution maps for a wide range of elements from across the periodic table. It is also capable of high precision (per mil) isotopic spot measurements with a spatial resolution of a few microns for a range of elements including C, N, O, S, Si, Mg, etc. Noble Gases facilities at CRPG and OU Ar/Ar Nu Instruments Noblesse is coupled with an ultra-low volume extraction line and with a choice of 213 nm UV laser or 1090 nm IR lasers, providing a wide range of analytical capability in Ar/Ar dating of lunar and meteorite samples. This instrument is unique with a mass resolution of 3000, and with the UV laser it has the capability to measure Ar isotope variation on a ca. 30 -micron resolution enabling detailed mapping of age and apparent age variation within minerals. The 1090 nm laser provides the capability to step-heat small samples. The laboratory is fully supported by sample preparation facilities and technical expertise in lunar and meteorite Ar/Ar analysis. Helium isotope facility. Analysis of the isotopes of helium in rocks and minerals. Determining the origin of gases in meteorites and ET return samples, dating surface exposure with cosmogenic 3He using the latest He isotope mass spectrometer, the GV Helix SFT, the first instrument installed in Europe. CRPG is an European leader in this domain. Non-Traditional stable Isotopes and radiogenic isotopes at VUA and CRPG The specific facility proposed for the TNA is the geochemistry labs used for the study of long (e.g. Rb- Sr, Sm-Nd…) and short-lived radioisotope (e.g. Mg- Al, Hf-W..), including also Os isotopes, stable and non traditional stable isotope facilities (e.g. Fe, Pb, Zn…). The facility comprises three multicollector Thermal ionization mass spectrometers (TIMS) and two multi-collector ICP-MS one of which is fitted with 193 nm laser for in situ work. In addition these instruments are fully supported by sample preparation labs (crushing, mineral separation/picking), a clean lab and geochemical support (XRF; ICP; ICP-MS etc). Data that can be obtained on samples containing sub nano gram to nanogram amounts. Organic matter analysis at OU Leco Pegasus IV GCxGC-TOFMS - mass spectrometric complete characterisation of very complex mixtures of organic materials. The Pegasus EPSC Abstracts, Vol. 3, EPSC2008-A-00437, 2008 European Planetary Science Congress, Author(s) 2008 4D GCxGC-TOFMS system, from Leco, provides the analyst with four dimensions of analytical resolution for significantly more complete sample analysis compared to conventional GC-Mass Spectrometry. The main advantages include: 1) The significantly increased sensitivity over the whole mass range (5- 1000 amu); 2)The separation of compounds that coelute on standard gas chromatograph systems; 3) Separation of analytes by volatility and polarity enables traditionally unresolved mixtures to be examined in detail, and vastly increases the number of compounds identified; 4) Greatly increased signal to noise ratio, due to compounds being separated from the column bleed of the first column on the second GC column and an enormous increase in the Spectral Generation Rate. A number of different pyrolysis and injection sample introduction facilities are available and access to off-line data processing and reference libraries. This is the only instrument of this type in a European laboratory with a significant focus on extraterrestrial materials. Thermo MAT 253 GC-IRMS -isotopic measurements of H, C or N on individual organic compounds in complex mixtures. One of only a few instruments of this type worldwide primarily dedicated to the analysis of extra-terrestrial materials. Supported by fully equipped sample preparation laboratories and GC-Mass Spectrometers required to develop the exact methodology necessary for optimal analysis of each sample. A number of different sample introduction injection and pyrolysis systems are available. Open University is one of the leading laboratories in the world for compound specific isotopic measurements of extra-terrestrial organics and this is one of a very few instruments of this type in the world largely dedicated to extra-terrestrial materials. Conclusion Currently planetary research is limited to meteorites and lunar samples but future return missions will provide enough material from comets and asteroids. A major focus of research in the next 5-10 years will be comparative planetology to understand the types of geochemical processes that can be expected on the (former) water rich regions of Mars to be sure that the detection of past life is unambiguous. The aim of this infrastructure is to provide a structured access to state of the art analytical facilities for European users.

  18. Measurements of the Solar Spectral Irradiance Variability over Solar Cycles 21 to 24

    NASA Astrophysics Data System (ADS)

    Woods, T. N.

    2017-12-01

    The solar irradiance is the primary natural energy input into Earth's atmosphere and climate system. Understanding the long-term variations of the solar spectral irradiance (SSI) over time scales of the 11-year solar activity cycle and longer is critical for most Sun-climate research topics. There are satellite measurements of the SSI since the 1970s that contribute to understanding the solar cycle variability over Solar Cycles 21 to 24. A limiting factor for the accuracy of these results is the uncertainties for the instrument degradation corrections, for which there are fairly large corrections relative to the amount of solar cycle variability at some wavelengths. A summary of these satellite SSI measurements, which are primarily in the ultraviolet and only recently in the visible and near infrared, will be presented. Examining SSI trends using a new analysis technique is helping to identify some uncorrected instrumental trends, which once applied to the SSI trends has the potential to provide more accurate solar cycle variability results. This new technique examines the SSI trends at different levels of solar activity to provide long-term trends in a SSI record, and one of the most common components of these derived long-term trends is a downward trend that we attribute to being most likely from uncorrected instrument degradation. Examples of this analysis will be presented for some of the satellite SSI measurements to demonstrate this new technique and how it has potential to improve the understanding of solar cycle variability and to clarify the uncertainties of the trends.

  19. Decoding the neural signatures of emotions expressed through sound.

    PubMed

    Sachs, Matthew E; Habibi, Assal; Damasio, Antonio; Kaplan, Jonas T

    2018-07-01

    Effective social functioning relies in part on the ability to identify emotions from auditory stimuli and respond appropriately. Previous studies have uncovered brain regions engaged by the affective information conveyed by sound. But some of the acoustical properties of sounds that express certain emotions vary remarkably with the instrument used to produce them, for example the human voice or a violin. Do these brain regions respond in the same way to different emotions regardless of the sound source? To address this question, we had participants (N = 38, 20 females) listen to brief audio excerpts produced by the violin, clarinet, and human voice, each conveying one of three target emotions-happiness, sadness, and fear-while brain activity was measured with fMRI. We used multivoxel pattern analysis to test whether emotion-specific neural responses to the voice could predict emotion-specific neural responses to musical instruments and vice-versa. A whole-brain searchlight analysis revealed that patterns of activity within the primary and secondary auditory cortex, posterior insula, and parietal operculum were predictive of the affective content of sound both within and across instruments. Furthermore, classification accuracy within the anterior insula was correlated with behavioral measures of empathy. The findings suggest that these brain regions carry emotion-specific patterns that generalize across sounds with different acoustical properties. Also, individuals with greater empathic ability have more distinct neural patterns related to perceiving emotions. These results extend previous knowledge regarding how the human brain extracts emotional meaning from auditory stimuli and enables us to understand and connect with others effectively. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Analysis of selected microflares observed by SphinX over the last minimum of solar activity

    NASA Astrophysics Data System (ADS)

    Siarkowski, Marek; Sylwester, Janusz; Sylwester, Barbara; Gryciuk, Magdalena

    The Solar Photometer in X-rays (SphinX) was designed to observe soft X-ray solar emission in the energy range between 1 keV and 15 keV with the resolution better than 0.5 keV. The instrument operated from February until November 2009 aboard CORONAS-Photon satellite, during the phase of exceptionally low minimum of solar activity. Here we use SphinX data for analysis of selected microflare-class events. We selected events of unusual lightcurves or location. Our study involves determination of temporal characteristics (times of start, maximum and end of flares) and analysis of physical conditions in flaring plasma (temperature, emission measure). Dedicated method has been used in order to remove emission not related to flare. Supplementary information about morphology and evolution of investigated events has been derived from the analysis of XRT/Hinode and SECCHI /STEREO images.

  1. An analysis of the characteristics of Indonesian industrial sectors: 2005-2010

    NASA Astrophysics Data System (ADS)

    Zuhdi, Ubaidillah

    2017-10-01

    The purpose of the current study is to analyze the characteristics of Indonesian industrial sectors from 2005 through 2010. The study employs the analysis instruments from the Input-Output (IO) analysis, namely the indices of the power of dispersion, and the sensitivity of dispersion. For 2005 and 2010, the study focuses on nine and seventeen industries, respectively. The results show that industry 3, manufacturing, placed the quadrant I on the analysis period. The fact shows that, from 2005 through 2010, the industry had a strong influence on the Indonesian economic activities, and received high impacts from the external aspects. In other words, the industry has great potency for the Indonesian economy. From the results one can also see that sector 4, electricity and gas, included in the quadrant I in 2010. This fact explains that the sector has also great potency for the economic activities of Indonesia. Thus, the Indonesian government should prioritize the industries development.

  2. Correlative Instrumental Neutron Activation Analysis, Light Microscopy, Transmission Electron Microscopy, and X-ray Microanalysis for Qualitative and Quantitative Detection of Colloidal Gold Spheres in Biological Specimens

    NASA Astrophysics Data System (ADS)

    Hillyer, Julián F.; Albrecht, Ralph M.

    1998-10-01

    : Colloidal gold, conjugated to ligands or antibodies, is routinely used as a label for the detection of cell structures by light (LM) and electron microscopy (EM). To date, several methods to count the number of colloidal gold labels have been employed with limited success. Instrumental neutron activation analysis (INAA), a physical method for the analysis of the elemental composition of materials, can be used to provide a quantitative index of gold accumulation in bulk specimens. Given that gold is not naturally found in biological specimens in any substantial amount and that colloidal gold and ligand conjugates can be prepared to yield uniform bead sizes, the amount of label can be calculated in bulk biological samples by INAA. Here we describe the use of INAA, LM, transmission EM, and X-ray microanalysis (EDX) in a model to determine both distribution (localization) and amount of colloidal gold at the organ, tissue, cellular, and ultrastructural levels in whole animal systems following administration. In addition, the sensitivity for gold in biological specimens by INAA is compared with that of inductively coupled plasma mass spectrometry (ICP-MS). The correlative use of INAA, LM, TEM, and EDX can be useful, for example, in the quantitative and qualitative tracking of various labeled molecular species following administration in vivo.

  3. Development and Implementation of Efficiency-Improving Analysis Methods for the SAGE III on ISS Thermal Model Originating

    NASA Technical Reports Server (NTRS)

    Liles, Kaitlin; Amundsen, Ruth; Davis, Warren; Scola, Salvatore; Tobin, Steven; McLeod, Shawn; Mannu, Sergio; Guglielmo, Corrado; Moeller, Timothy

    2013-01-01

    The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument is the fifth in a series of instruments developed for monitoring aerosols and gaseous constituents in the stratosphere and troposphere. SAGE III will be delivered to the International Space Station (ISS) via the SpaceX Dragon vehicle in 2015. A detailed thermal model of the SAGE III payload has been developed in Thermal Desktop (TD). Several novel methods have been implemented to facilitate efficient payload-level thermal analysis, including the use of a design of experiments (DOE) methodology to determine the worst-case orbits for SAGE III while on ISS, use of TD assemblies to move payloads from the Dragon trunk to the Enhanced Operational Transfer Platform (EOTP) to its final home on the Expedite the Processing of Experiments to Space Station (ExPRESS) Logistics Carrier (ELC)-4, incorporation of older models in varying unit sets, ability to change units easily (including hardcoded logic blocks), case-based logic to facilitate activating heaters and active elements for varying scenarios within a single model, incorporation of several coordinate frames to easily map to structural models with differing geometries and locations, and streamlined results processing using an Excel-based text file plotter developed in-house at LaRC. This document presents an overview of the SAGE III thermal model and describes the development and implementation of these efficiency-improving analysis methods.

  4. Outcomes of the JNT 1955 Phase I Viability Study of Gamma Emission Tomography for Spent Fuel Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jacobsson-Svard, Staffan; Smith, Leon E.; White, Timothy

    The potential for gamma emission tomography (GET) to detect partial defects within a spent nuclear fuel assembly has been assessed within the IAEA Support Program project JNT 1955, phase I, which was completed and reported to the IAEA in October 2016. Two safeguards verification objectives were identified in the project; (1) independent determination of the number of active pins that are present in a measured assembly, in the absence of a priori information about the assembly; and (2) quantitative assessment of pin-by-pin properties, for example the activity of key isotopes or pin attributes such as cooling time and relative burnup,more » under the assumption that basic fuel parameters (e.g., assembly type and nominal fuel composition) are known. The efficacy of GET to meet these two verification objectives was evaluated across a range of fuel types, burnups and cooling times, while targeting a total interrogation time of less than 60 minutes. The evaluations were founded on a modelling and analysis framework applied to existing and emerging GET instrument designs. Monte Carlo models of different fuel types were used to produce simulated tomographer responses to large populations of “virtual” fuel assemblies. The simulated instrument response data were then processed using a variety of tomographic-reconstruction and image-processing methods, and scoring metrics were defined and used to evaluate the performance of the methods.This paper describes the analysis framework and metrics used to predict tomographer performance. It also presents the design of a “universal” GET (UGET) instrument intended to support the full range of verification scenarios envisioned by the IAEA. Finally, it gives examples of the expected partial-defect detection capabilities for some fuels and diversion scenarios, and it provides a comparison of predicted performance for the notional UGET design and an optimized variant of an existing IAEA instrument.« less

  5. Decoupling Solar Variability and Instrument Trends Using the Multiple Same-Irradiance-Level (MuSIL) Analysis Technique

    NASA Astrophysics Data System (ADS)

    Woods, Thomas N.; Eparvier, Francis G.; Harder, Jerald; Snow, Martin

    2018-05-01

    The solar spectral irradiance (SSI) dataset is a key record for studying and understanding the energetics and radiation balance in Earth's environment. Understanding the long-term variations of the SSI over timescales of the 11-year solar activity cycle and longer is critical for many Sun-Earth research topics. Satellite measurements of the SSI have been made since the 1970s, most of them in the ultraviolet, but recently also in the visible and near-infrared. A limiting factor for the accuracy of previous solar variability results is the uncertainties for the instrument degradation corrections, which need fairly large corrections relative to the amount of solar cycle variability at some wavelengths. The primary objective of this investigation has been to separate out solar cycle variability and any residual uncorrected instrumental trends in the SSI measurements from the Solar Radiation and Climate Experiment (SORCE) mission and the Thermosphere, Mesosphere, Ionosphere, Energetic, and Dynamics (TIMED) mission. A new technique called the Multiple Same-Irradiance-Level (MuSIL) analysis has been developed, which examines an SSI time series at different levels of solar activity to provide long-term trends in an SSI record, and the most common result is a downward trend that most likely stems from uncorrected instrument degradation. This technique has been applied to each wavelength in the SSI records from SORCE (2003 - present) and TIMED (2002 - present) to provide new solar cycle variability results between 27 nm and 1600 nm with a resolution of about 1 nm at most wavelengths. This technique, which was validated with the highly accurate total solar irradiance (TSI) record, has an estimated relative uncertainty of about 5% of the measured solar cycle variability. The MuSIL results are further validated with the comparison of the new solar cycle variability results from different solar cycles.

  6. Screening for frailty in older adults using a self-reported instrument.

    PubMed

    Nunes, Daniella Pires; Duarte, Yeda Aparecida de Oliveira; Santos, Jair Lício Ferreira; Lebrão, Maria Lúcia

    2015-01-01

    OBJECTIVE To validate a screening instrument using self-reported assessment of frailty syndrome in older adults. METHODS This cross-sectional study used data from the Saúde, Bem-estar e Envelhecimento study conducted in Sao Paulo, SP, Southeastern Brazil. The sample consisted of 433 older adult individuals (≥ 75 years) assessed in 2009. The self-reported instrument can be applied to older adults or their proxy respondents and consists of dichotomous questions directly related to each component of the frailty phenotype, which is considered the gold standard model: unintentional weight loss, fatigue, low physical activity, decreased physical strength, and decreased walking speed. The same classification proposed in the phenotype was utilized: not frail (no component identified); pre-frail (presence of one or two components), and frail (presence of three or more components). Because this is a screening instrument, "process of frailty" was included as a category (pre-frail and frail). Cronbach's α was used in psychometric analysis to evaluate the reliability and validity of the criterion, the sensitivity, the specificity, as well as positive and negative predictive values. Factor analysis was used to assess the suitability of the proposed number of components. RESULTS Decreased walking speed and decreased physical strength showed good internal consistency (α = 0.77 and 0.72, respectively); however, low physical activity was less satisfactory (α = 0.63). The sensitivity and specificity for identifying pre-frail individuals were 89.7% and 24.3%, respectively, while those for identifying frail individuals were 63.2% and 71.6%, respectively. In addition, 89.7% of the individuals from both the evaluations were identified in the "process of frailty" category. CONCLUSIONS The self-reported assessment of frailty can identify the syndrome among older adults and can be used as a screening tool. Its advantages include simplicity, rapidity, low cost, and ability to be used by different professionals.

  7. Screening for frailty in older adults using a self-reported instrument

    PubMed Central

    Nunes, Daniella Pires; Duarte, Yeda Aparecida de Oliveira; Santos, Jair Lício Ferreira; Lebrão, Maria Lúcia

    2015-01-01

    OBJECTIVE To validate a screening instrument using self-reported assessment of frailty syndrome in older adults. METHODS This cross-sectional study used data from the Saúde, Bem-estar e Envelhecimento study conducted in Sao Paulo, SP, Southeastern Brazil. The sample consisted of 433 older adult individuals (≥ 75 years) assessed in 2009. The self-reported instrument can be applied to older adults or their proxy respondents and consists of dichotomous questions directly related to each component of the frailty phenotype, which is considered the gold standard model: unintentional weight loss, fatigue, low physical activity, decreased physical strength, and decreased walking speed. The same classification proposed in the phenotype was utilized: not frail (no component identified); pre-frail (presence of one or two components), and frail (presence of three or more components). Because this is a screening instrument, “process of frailty” was included as a category (pre-frail and frail). Cronbach’s α was used in psychometric analysis to evaluate the reliability and validity of the criterion, the sensitivity, the specificity, as well as positive and negative predictive values. Factor analysis was used to assess the suitability of the proposed number of components. RESULTS Decreased walking speed and decreased physical strength showed good internal consistency (α = 0.77 and 0.72, respectively); however, low physical activity was less satisfactory (α = 0.63). The sensitivity and specificity for identifying pre-frail individuals were 89.7% and 24.3%, respectively, while those for identifying frail individuals were 63.2% and 71.6%, respectively. In addition, 89.7% of the individuals from both the evaluations were identified in the “process of frailty” category. CONCLUSIONS The self-reported assessment of frailty can identify the syndrome among older adults and can be used as a screening tool. Its advantages include simplicity, rapidity, low cost, and ability to be used by different professionals. PMID:25741658

  8. The Active Role of Instruments in Articulating Knowing and Knowledge: The Case of Animal Qualification Practices in Breeding Organisations

    ERIC Educational Resources Information Center

    Labatut, Julie; Aggeri, Franck; Astruc, Jean-Michel; Bibe, Bernard; Girard, Nathalie

    2009-01-01

    Purpose: The purpose of this paper is to investigate the role of instruments defined as artefacts, rules, models or norms, in the articulation between knowing-in-practice and knowledge, in learning processes. Design/methodology/approach: The paper focuses on a distributed, knowledge-intensive and instrumented activity at the core of any collective…

  9. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  10. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  11. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  12. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  13. 10 CFR 35.2060 - Records of calibrations of instruments used to measure the activity of unsealed byproduct material.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Records of calibrations of instruments used to measure the activity of unsealed byproduct material. 35.2060 Section 35.2060 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2060 Records of calibrations of instruments used to measure...

  14. Measurement techniques for trace metals in coal-plant effluents: A brief review

    NASA Technical Reports Server (NTRS)

    Singh, J. J.

    1979-01-01

    The strong features and limitations of techniques for determining trace elements in aerosols emitted from coal plants are discussed. Techniques reviewed include atomic absorption spectroscopy, charged particle scattering and activation, instrumental neutron activation analysis, gas/liquid chromatography, gas chromatographic/mass spectrometric methods, X-ray fluorescence, and charged-particle-induced X-ray emission. The latter two methods are emphasized. They provide simultaneous, sensitive multielement analyses and lend themselves readily to depth profiling. It is recommended that whenever feasible, two or more complementary techniques should be used for analyzing environmental samples.

  15. Fermi LAT detection of gamma-ray flaring activity from the blazar MG J221916+1806 through the Fermi All-sky Variability Analysis (FAVA)

    NASA Astrophysics Data System (ADS)

    Ajello, M.; Kocevski, D.; Gasparrini, D.; Buehler, R.; Thompson, D.; Ciprini, S.

    2014-03-01

    During the week between March 17 and March 24, 2014, the Large Area Telescope (LAT), one of the two instruments on the Fermi Gamma-ray Space Telescope, has observed increased gamma-ray activity from a source positionally coincident with the flat-spectrum radio quasar MG J221916+1806 (also known as 2FGL J2219.1+1805, Nolan et al., 2012, ApJS, 199, 31, and CGRaBS J2219+1806, Healey et al. ...

  16. Analysis of active volcanoes from the Earth Observing System

    NASA Technical Reports Server (NTRS)

    Mouginis-Mark, Peter; Rowland, Scott; Crisp, Joy; Glaze, Lori; Jones, Kenneth; Kahle, Anne; Pieri, David; Zebker, Howard; Krueger, Arlin; Walter, Lou

    1991-01-01

    The Earth Observing System (EOS) scheduled for launch in 1997 and 1999 is briefly described, and the EOS volcanology investigation objectives are discussed. The volcanology investigation will include long- and short-term monitoring of selected volcanoes, the detection of precursor activity associated with unanticipated eruptions, and a detailed study of on-going eruptions. A variety of instruments on the EOS platforms will enable the study of local- and regional-scale thermal and deformational features of volcanoes, and the chemical and structural features of volcanic eruption plumes and aerosols.

  17. Transient conduction-radiation analysis of an absolute active cavity radiometer using finite elements

    NASA Technical Reports Server (NTRS)

    Mahan, J. R.; Kowsary, F.; Tira, N.; Gardiner, B. D.

    1987-01-01

    A NASA-developed finite element-based model of a generic active cavity radiometer (ACR) has been developed in order to study the dependence on operating temperature of the closed-loop and open-loop transient response of the instrument. Transient conduction within the sensing element is explored, and the transient temperature distribution resulting from the application of a time-varying radiative boundary condition is calculated. The results verify the prediction that operation of an ACR at cryogenic temperatures results in large gains in frequency response.

  18. The morphology of flare phenomena, magnetic fields, and electric currents in active regions. I - Introduction and methods

    NASA Technical Reports Server (NTRS)

    Canfield, Richard C.; De La Beaujardiere, J.-F.; Fan, Yuhong; Leka, K. D.; Mcclymont, A. N.; Metcalf, Thomas R.; Mickey, Donald L.; Wuelser, Jean-Pierre; Lites, Bruce W.

    1993-01-01

    Electric current systems in solar active regions and their spatial relationship to sites of electron precipitation and high-pressure in flares were studied with the purpose of providing observational evidence for or against the flare models commonly discussed in the literature. The paper describes the instrumentation, the data used, and the data analysis methods, as well as improvements made upon earlier studies. Several flare models are overviewed, and the predictions yielded by each model for the relationships of flares to the vertical current systems are discussed.

  19. Infrared Algorithm Development for Ocean Observations with EOS/MODIS

    NASA Technical Reports Server (NTRS)

    Brown, Otis B.

    1997-01-01

    Efforts continue under this contract to develop algorithms for the computation of sea surface temperature (SST) from MODIS infrared measurements. This effort includes radiative transfer modeling, comparison of in situ and satellite observations, development and evaluation of processing and networking methodologies for algorithm computation and data accession, evaluation of surface validation approaches for IR radiances, development of experimental instrumentation, and participation in MODIS (project) related activities. Activities in this contract period have focused on radiative transfer modeling, evaluation of atmospheric correction methodologies, undertake field campaigns, analysis of field data, and participation in MODIS meetings.

  20. Analytical techniques and instrumentation: A compilation. [analytical instrumentation, materials performance, and systems analysis

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Technical information is presented covering the areas of: (1) analytical instrumentation useful in the analysis of physical phenomena; (2) analytical techniques used to determine the performance of materials; and (3) systems and component analyses for design and quality control.

  1. Evaluating the effectiveness of impact assessment instruments: Theorising the nature and implications of their political constitution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cashmore, Matthew, E-mail: m.cashmore@uea.ac.u; Richardson, Tim; Hilding-Ryedvik, Tuija

    2010-11-15

    The central role of impact assessment instruments globally in policy integration initiatives has been cemented in recent years. Associated with this trend, but also reflecting political emphasis on greater accountability in certain policy sectors and a renewed focus on economic competitiveness in Western countries, demand has increased for evidence that these instruments are effective (however defined). Resurgent interest in evaluation has not, however, been accompanied by the conceptual developments required to redress longstanding theoretical problems associated with such activities. In order to sharpen effectiveness evaluation theory for impact assessment instruments this article critically examines the neglected issue of their politicalmore » constitution. Analytical examples are used to concretely explore the nature and significance of the politicisation of impact assessment. It is argued that raising awareness about the political character of impact assessment instruments, in itself, is a vital step in advancing effectiveness evaluation theory. Broader theoretical lessons on the framing of evaluation research are also drawn from the political analysis. We conclude that, at least within the contemporary research context, learning derived from analysing the meaning and implications of plural interpretations of effectiveness represents the most constructive strategy for advancing impact assessment and policy integration theory.« less

  2. Antimicrobial efficacy of 2.5% sodium hypochlorite, 2% chlorhexidine, and ozonated water as irrigants in mesiobuccal root canals with severe curvature of mandibular molars

    PubMed Central

    Pinheiro, Sergio Luiz; da Silva, Caio Cesar; da Silva, Lucas Augusto; Cicotti, Marina P.; Bueno, Carlos Eduardo da Silveira; Fontana, Carlos Eduardo; Pagrion, Letícia R.; Dalmora, Natália P.; Daque, Thaís T.; de Campos, Francisco UF

    2018-01-01

    Objective: The aim of this study is to evaluate the antimicrobial efficacy of 2.5% sodium hypochlorite, 2% chlorhexidine, and ozonated water on biofilms of Enterococcus faecalis, Streptococcus mutans, and Candida albicans in mesiobuccal root canals with severe curvature of mandibular molars. Materials and Methods: This was an experimental ex vivo study in microbiologic laboratory. Sixty mesiobuccal root canals with severe curvature of mandibular molars were contaminated with standard strains of E. faecalis, S. mutans, and C. albicans. The specimens were randomly divided into four groups (n = 15) according to irrigating solution: SH: 2.5% sodium hypochlorite; CH: 2% chlorhexidine; O3: ozonated water; and control: double-distilled water. The mesiobuccal root canals of all groups were instrumented with the WaveOne Gold Primary reciprocating system. Three cycles of instrumentation with three short in-and-out brushing motions were performed: (1) in the coronal third, (2) in the middle third, and (3) in the apical third of the canal. A ProGlider file was used before the first cycle. Statistical Analysis: Statistical analysis was performed using one-way analysis of variance followed by Tukey's multiple comparison test. Samples were collected for viable bacterial counts before and after instrumentation. Results: All groups showed significant biofilm reduction after irrigation (P < 0.01). After instrumentation, sodium hypochlorite (98.07%), chlorhexidine (98.31%), and ozonated water (98.02%) produced a significantly reduction in bacterial counts compared with double-distilled water (control, 72.98%) (P < 0.01). Conclusion: All irrigants tested in this study showed similar antimicrobial activity. Thus, ozonated water may be an option for microbial reduction in the root canal system. PMID:29657531

  3. Activities in Teaching Weather

    ERIC Educational Resources Information Center

    Tonn, Martin

    1977-01-01

    Presented is a unit composed of activities for teaching weather. Topics include cloud types and formation, simple weather instruments, and the weather station. Illustrations include a weather chart and instruments. A bibliography is given. (MA)

  4. Assessment of factors that predict physical activity among Oklahoma clergy: a theory of planned behavior approach.

    PubMed

    Gwin, Shannon; Taylor, E Laurette; Branscum, Paul; Hofford, Craig

    2013-01-01

    The purpose of this study was to examine predictors of physical activity among clergy members in Oklahoma, using the theory of planned behavior. A 51-item valid and reliable instrument, measuring theory of planned behavior constructs and physical activity, was developed and administered to 141 clergy members. Results indicated that the majority of those surveyed were white (93%), college educated (97%), and overweight or obese (84%). Stepwise multiple regression analysis found that intentions accounted for 13.8% of the variance of physical activity whereas attitudes, subjective norms, and perceived behavioral control accounted for 54.8% of the variance of intention. Implications for intervention development are discussed.

  5. TOPLEX: Teleoperated Lunar Explorer. Instruments and Operational Concepts for an Unmanned Lunar Rover

    NASA Technical Reports Server (NTRS)

    Blacic, James D.

    1992-01-01

    A Teleoperated Lunar Explorer, or TOPLEX, consisting of a lunar lander payload in which a small, instrument-carrying lunar surface rover is robotically landed and teleoperated from Earth to perform extended lunar geoscience and resource evaluation traverses is proposed. The rover vehicle would mass about 100 kg and carry approximately 100 kg of analytic instruments. Four instruments are envisioned: (1) a Laser-Induced Breakdown Spectrometer (LIBS) for geochemical analysis at ranges up to 100 m, capable of operating in three different modes; (2) a combined x-ray fluorescence and x-ray diffraction (XRF/XRD) instrument for elemental and mineralogic analysis of acquired samples; (3) a mass spectrometer system for stepwise heating analysis of gases released from acquired samples; and (4) a geophysical instrument package for subsurface mapping of structures such as lava tubes.

  6. Optimization of biological and instrumental detection of explosives and ignitable liquid residues including canines, SPME/ITMS and GC/MSn

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Harper, Ross J.; Perr, Jeannette M.; Almirall, Jose R.

    2003-09-01

    A comprehensive study and comparison is underway using biological detectors and instrumental methods for the rapid detection of ignitable liquid residues (ILR) and high explosives. Headspace solid phase microextraction (SPME) has been demonstrated to be an effective sampling method helping to identify active odor signature chemicals used by detector dogs to locate forensic specimens as well as a rapid pre-concentration technique prior to instrumental detection. Common ignitable liquids and common military and industrial explosives have been studied including trinitrotoluene, tetryl, RDX, HMX, EGDN, PETN and nitroglycerine. This study focuses on identifying volatile odor signature chemicals present, which can be used to enhance the level and reliability of detection of ILR and explosives by canines and instrumental methods. While most instrumental methods currently in use focus on particles and on parent organic compounds, which are often involatile, characteristic volatile organics are generally also present and can be exploited to enhance detection particularly for well-concealed devices. Specific examples include the volatile odor chemicals 2-ethyl-1-hexanol and cyclohexanone, which are readily available in the headspace of the high explosive composition C-4; whereas, the active chemical cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX) is not. The analysis and identification of these headspace 'fingerprint' organics is followed by double-blind dog trials of the individual components using certified teams in an attempt to isolate and understand the target compounds to which dogs are sensitive. Studies to compare commonly used training aids with the actual target explosive have also been undertaken to determine their suitability and effectiveness. The optimization of solid phase microextraction (SPME) combined with ion trap mobility spectrometry (ITMS) and gas chromatography/mass spectrometry/mass spectrometry (GC/MSn) is detailed including interface development and comparisons of limits of detection. These instrumental methods are being optimized in order to detect the same target odor chemicals used by detector dogs to reliably locate explosives and ignitable liquids.

  7. An Introduction to the Global Space-based Inter-Calibration System from a EUMETSAT Perspective

    NASA Astrophysics Data System (ADS)

    Wagner, S. C.; Hewison, T.; Roebeling, R. A.; Koenig, M.; Schulz, J.; Miu, P.

    2012-04-01

    The Global Space-based Inter-Calibration System (GSICS) (Goldberg and al. 2011) is an international collaborative effort which aims to monitor, improve and harmonize the quality of observations from operational weather and environmental satellites of the Global Observing System (GOS). GSICS aims at ensuring consistent accuracy among space-based observations worldwide for climate monitoring, weather forecasting, and environmental applications. This is achieved through a comprehensive calibration strategy, which involves monitoring instrument performances, operational inter-calibration of satellite instruments, tying the measurements to absolute references and standards, and recalibration of archived data. A major part of this strategy involves direct comparison of collocated observations from pairs of satellite instruments, which are used to systematically generate calibration functions to compare and correct the calibration of monitored instruments to references. These GSICS Corrections are needed for accurately integrating data from multiple observing systems into both near real-time and re-analysis products, applications and services. This paper gives more insight into the activities carried out by EUMETSAT as a GSICS Processing and Research Centre. Currently these are closely bound to the in-house development and operational implementation of calibration methods for solar and thermal band channels of geostationary and polar-orbiting satellites. They include inter-calibration corrections for Meteosat imagers using reference instruments such as the Moderate Resolution Imaging Spectroradiometer (MODIS) on-board the Aqua satellite for solar band channels, the Infrared Atmospheric Sounding Interferometer (IASI) on-board Metop-A and, for historic archive data, the High-resolution InfraRed Sounder (HIRS). Additionally, bias monitoring is routinely performed, allowing users to visualise the calibration accuracy of the instruments in near real-time. These activities are based on principles and protocols defined by the GSICS Research Working Group and Data Management Working Group, which require assessment of the calibration uncertainties to ensure the traceability to community references.

  8. Development of the Probing In-Situ with Neutron and Gamma Rays (PING) Instrument for Planetary Science Applications

    NASA Technical Reports Server (NTRS)

    Parsons, A.; Bodnarik, J.; Burger, D.; Evans, L.; Floyd, S; Lim, L.; McClanahan, T.; Namkung, M.; Nowicki, S.; Schweitzer, J.; hide

    2011-01-01

    The Probing In situ with Neutrons and Gamma rays (PING) instrument is a promising planetary science application of the active neutron-gamma ray technology that has been used successfully in oil field well logging and mineral exploration on Earth for decades. Similar techniques can be very powerful for non-invasive in situ measurements of the subsurface elemental composition on other planets. The objective of our active neutron-gamma ray technology program at NASA Goddard Space Flight Center (NASA/GSFC) is to bring instruments using this technology to the point where they can be flown on a variety of surface lander or rover missions to the Moon, Mars, Venus, asteroids, comets and the satellites of the outer planets. PING combines a 14 MeV deuterium-tritium pulsed neutron generator with a gamma ray spectrometer and two neutron detectors to produce a landed instrument that can determine the elemental composition of a planet down to 30 - 50 cm below the planet's surface. The penetrating nature of.5 - 10 MeV gamma rays and 14 MeV neutrons allows such sub-surface composition measurements to be made without the need to drill into or otherwise disturb the planetary surface, thus greatly simplifying the lander design. We are currently testing a PING prototype at a unique outdoor neutron instrumentation test facility at NASA/GSFC that provides two large (1.8 m x 1.8 m x.9 m) granite and basalt test formations placed outdoors in an empty field. Since an independent trace elemental analysis has been performed on both the Columbia River basalt and Concord Gray granite materials, these samples present two known standards with which to compare PING's experimentally measured elemental composition results. We will present experimental results from PING measurements of both the granite and basalt test formations and show how and why the optimum PING instrument operating parameters differ for studying the two materials.

  9. Purity of targets prepared on Cu substrates

    NASA Astrophysics Data System (ADS)

    Méens, A.; Rossini, I.; Sens, J. C.

    1993-09-01

    The purity of several elemental self-supporting targets usually prepared by evaporation onto soluble Cu substrates has been studied. The targets were analysed by Rutherford backscattering and instrumental neutron activation analysis. Because of the high percentage of Cu observed in some Si targets, further measurements, including transmission electron microscopy, have been performed on Si targets deposited by e-gun bombardment onto Cu and ion-beam sputtering onto betaine.

  10. Prompt and delayed NAA techniques for the characterization of specimen bank materials.

    PubMed

    Rossbach, M; Stoeppler, M; Byrne, A R

    1993-11-01

    The combined application of instrumental-, radiochemical- and prompt gamma neutron activation analysis to two spruce shoot materials from the German Environmental Specimen Bank (ESB) resulted in information on 50 elements, covering more than 50% of the total mass. Comparison of the element concentrations in the 'fingerprint' mode clearly indicated a different status of heavy metal pollution at the two distinct collecting sites.

  11. Effectiveness Monitoring Report, MWMF Tritium Phytoremediation Interim Measures.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hitchcock, Dan; Blake, John, I.

    2003-02-10

    This report describes and presents the results of monitoring activities during irrigation operations for the calendar year 2001 of the MWMF Interim Measures Tritium Phytoremediation Project. The purpose of this effectiveness monitoring report is to provide the information on instrument performance, analysis of CY2001 measurements, and critical relationships needed to manage irrigation operations, estimate efficiency and validate the water and tritium balance model.

  12. Latest NASA Instrument Cost Model (NICM): Version VI

    NASA Technical Reports Server (NTRS)

    Mrozinski, Joe; Habib-Agahi, Hamid; Fox, George; Ball, Gary

    2014-01-01

    The NASA Instrument Cost Model, NICM, is a suite of tools which allow for probabilistic cost estimation of NASA's space-flight instruments at both the system and subsystem level. NICM also includes the ability to perform cost by analogy as well as joint confidence level (JCL) analysis. The latest version of NICM, Version VI, was released in Spring 2014. This paper will focus on the new features released with NICM VI, which include: 1) The NICM-E cost estimating relationship, which is applicable for instruments flying on Explorer-like class missions; 2) The new cluster analysis ability which, alongside the results of the parametric cost estimation for the user's instrument, also provides a visualization of the user's instrument's similarity to previously flown instruments; and 3) includes new cost estimating relationships for in-situ instruments.

  13. Wavefront sensors for the active control of earth observation optical instruments

    NASA Astrophysics Data System (ADS)

    Velluet, Marie-Thérèse; Michau, Vincent; Rousset, Gérard

    2018-04-01

    This paper, "Wavefront sensors for the active control of earth observation optical instruments," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  14. Reliability and Construct Validity of the Patient-Reported Outcomes Measurement Information System (PROMIS) Instruments in Women with Fibromyalgia.

    PubMed

    Merriwether, Ericka N; Rakel, Barbara A; Zimmerman, Miriam B; Dailey, Dana L; Vance, Carol G T; Darghosian, Leon; Golchha, Meenakshi; Geasland, Katherine M; Chimenti, Ruth; Crofford, Leslie J; Sluka, Kathleen A

    2017-08-01

    The Patient-Reported Outcomes Measurement Information System (PROMIS) was developed to standardize measurement of clinically relevant patient-reported outcomes. This study evaluated the reliability and construct validity of select PROMIS static short-form (SF) instruments in women with fibromyalgia. Analysis of baseline data from the Fibromyalgia Activity Study with TENS (FAST), a randomized controlled trial of the efficacy of transcutaneous electrical nerve stimulation. Dual site, university-based outpatient clinics. Women aged 20 to 67 years diagnosed with fibromyalgia. Participants completed the Revised Fibromyalgia Impact Questionnaire (FIQR) and 10 PROMIS static SF instruments. Internal consistency was calculated using Cronbach alpha. Convergent validity was examined against the FIQR using Pearson correlation and multiple regression analysis. PROMIS static SF instruments had fair to high internal consistency (Cronbach α = 0.58 to 0.94, P  < 0.05). PROMIS 'physical function' domain score was highly correlated with FIQR 'function' score (r = -0.73). The PROMIS 'total' score was highly correlated with the FIQR total score (r = -0.72). Correlations with FIQR total score of each of the three PROMIS domain scores were r = -0.65 for 'physical function,' r = -0.63 for 'global,' and r = -0.57 for 'symptom' domain. PROMIS 'physical function,' 'global,' and 'symptom' scores explained 58% of the FIQR total score variance. Select PROMIS static SF instruments demonstrate convergent validity with the FIQR, a legacy measure of fibromyalgia disease severity. These results highlight the potential utility of select PROMIS static SFs for assessment and tracking of patient-reported outcomes in fibromyalgia. © 2016 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  15. Metop SG Ice Cloud Imager data analysis preparations

    NASA Astrophysics Data System (ADS)

    Eriksson, Patrick; Mendrok, Jana; Ekelund, Robin; Rydberg, Bengt; Brath, Manfred; Buehler, Stefan A.

    2017-04-01

    The Ice Cloud Imager (ICI), one the instruments to be onboard the second generation (SG) of Metop satellites, will be the first operational instrument making use of sub-millimeter wavelengths. Increasing the sensitivity of microwave ice hydrometeor measurements with at least two orders of magnitude, its primary aim is to characterize the bulk mass of ice hydrometeors, where the basic retrieval products will be ice water path, mean mass size, and mean mass altitude. With the expected competitive accuracy it can e.g. complement the narrow horizontal coverage of active instruments. Here we present our activities to develop and improve the data analysis for passive sub-millimeter sensors and ICI in particular, where for the latter we are also developing the froaen hydrometeor retrieval algorithm on behalf of EUMETSAT and its NWC-SAF. One crucial aspect in the data analysis is the quality of the forward modeling, the ability to produce realistic, statistically representative synthetic measurements and to reproduce the performed observations, which poses challenges regarding representation of hydrometeor microphysical as well as optical properties and of the radiative transfer problem itself (atmospheric dimensionality, polarization, etc.). One of our core activities is the creation of a consistent database of ice hydrometeor single scattering properties that covers not only ICI applications, but passive and active sensors in the whole microwave region. The database will fill the gaps (spectral, temperature, habits) of and between existing databases (e.g. by Liu, Hong, Ding, Kuo) and will also hold data for oriented particles. Furthermore, sensitivity to forward modeling assumptions is tested, and the results are validated statistically versus existing (satellite microwave and airborne sub-millimeter) observations. These assumptions include microphysics (e.g. size distributions, habit choices, particle orientation) as well as model complexity (e.g. 3D effects, consideration of polarization). Regarding 3D effects, we e.g. find ``shadow effects'' of the cloud in the order of several Kelvin in the true 3D versus a slant independent column solution. Beside the accuracy of the forward model, also its computation time requirements are essential targeting operational processing. Therefore, we also compare the performance (in accuracy and speed) of different scattering radiative transfer solvers we have at hand, which apply different, independent solution approaches (e.g. Monte Carlo, Discrete Ordinate, Doubling-and-adding) with different level of model complexity.

  16. THE RESPONSE OF SOME HEALTH PHYSICS INSTRUMENTS TO SODIUM-24 AND CHLORINE- 38 ACTIVITIES IN POLYTHENE MANPHANTOMS AND THE HUMAN BODY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peabody, C.O.

    1963-12-01

    Measurements were made of the response of five commonly used health physics instruments when held near polythene man-phantoms filled with aqueous solutions containing sodium-24 and chlorine-38. The ratios of the wholebody chlorine-38 and sodium-24 activities are calculated for various periods of accidental human irradiation by neutrons. These ratios and the phantom results are used to estimate the response of the five instruments when held near the human body at various times after irradiation. Relative contributions of the chlorine-38 and sodium-24 to the instrument indications are listed. The tabulated data enable the instrument readings to be converted to wholebody sodium- 24more » activity at the time of irradiation. This may be used as a quick estimate of the degree of neutron irradiation. (auth)« less

  17. Tips and tricks for flow cytometry-based analysis and counting of microparticles.

    PubMed

    Poncelet, Philippe; Robert, Stéphane; Bailly, Nicolas; Garnache-Ottou, Francine; Bouriche, Tarik; Devalet, Bérangère; Segatchian, Jerard H; Saas, Philippe; Mullier, François

    2015-10-01

    Submicron-sized extra-cellular vesicles generated by budding from the external cell membranes, microparticles (MPs) are important actors in transfusion as well as in other medical specialties. After briefly positioning their role in the characterization of labile blood products, this technically oriented chapter aims to review practical points that need to be considered when trying to use flow cytometry for the analysis, characterization and absolute counting of MP subsets. Subjects of active discussions relative to instrumentation will include the choice of the trigger parameter, possible standardization approaches requiring instrument quality-control, origin and control of non-specific background and of coincidence artifacts, choice of the type of electronic signals, optimal sheath fluid and sample speed. Questions related to reagents will cover target antigens and receptors, multi-color reagents, negative controls, enumeration of MPs and limiting artifacts due to unexpected (micro-) coagulation of plasma samples. Newly detected problems are generating innovative solutions and flow cytometry will continue to remain the technology of choice for the analysis of MPs, in the domain of transfusion as well as in many diverse specialties. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Level crossing analysis of cosmic microwave background radiation: a method for detecting cosmic strings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Movahed, M. Sadegh; Khosravi, Shahram, E-mail: m.s.movahed@ipm.ir, E-mail: khosravi@ipm.ir

    2011-03-01

    In this paper we study the footprint of cosmic string as the topological defects in the very early universe on the cosmic microwave background radiation. We develop the method of level crossing analysis in the context of the well-known Kaiser-Stebbins phenomenon for exploring the signature of cosmic strings. We simulate a Gaussian map by using the best fit parameter given by WMAP-7 and then superimpose cosmic strings effects on it as an incoherent and active fluctuations. In order to investigate the capability of our method to detect the cosmic strings for the various values of tension, Gμ, a simulated puremore » Gaussian map is compared with that of including cosmic strings. Based on the level crossing analysis, the superimposed cosmic string with Gμ∼>4 × 10{sup −9} in the simulated map without instrumental noise and the resolution R = 1' could be detected. In the presence of anticipated instrumental noise the lower bound increases just up to Gμ∼>5.8 × 10{sup −9}.« less

  19. MicroMAPS: Leveraging Federal and Universities' Resources for Atmospheric Sciences Research and Education

    NASA Astrophysics Data System (ADS)

    Sandy, M.; Companion, J. A.; Connors, V. S.

    2007-05-01

    NASA Langley Research Center approached the Virginia Space Grant Consortium, a NASA-sponsored coalition of universities, NASA research centers and state agencies with the opportunity to develop a scientific mission and flight opportunities for an un-flown atmospheric composition remote sensor, MicroMAPS. The resulting partnership led to new life for this instrument from a space-borne carbon monoxide remote sensor to an high altitude airborne instrument that measures tropospheric carbon monoxide in the near infrared portion of the spectrum. The five year effort to date has leveraged the existing instrument with work by student teams overseen by faculty and NASA advisors, with both NASA and industry contributions. The result is a viable instrument system that has flown in four international scientific field campaigns aboard the Scaled Composites Proteus aircraft, generating 300 plus hours of CO data to date over North America, Italy, the Mediterranean, England, the North Sea, Darwin, Northern Australia, the Atlantic Ocean, the Indian Ocean, and the Pacific Ocean between Australia and California. A relatively small investment by NASA and contributions by 56 students and nine faculty members, both active and retired NASA engineers and scientists, as well as a Canadian aerospace research company (which designed and built the MicroMAPS instrument) yielded successful results that go well beyond the instrument and data retrieved. The effort provided a valuable educational research experience for students from three universities whose work included contributions in: 1) Development of the instrument system and pod design for the Proteus flights; 2) Development of assessment strategy and analysis of instrument performance; 3) Development of the operations and data management strategy; 4) Contributions to development of design, implementation, and analysis of sensor calibration at Resonance Ltd., Barrie, Canada 5) Development of a new data reduction strategy for the airborne configuration over northern mid-latitudes and tropical regions. 6) Development of the instrument system and pod design for possible flights on Altair (a unmanned airborne vehicle managed at the NASA Dryden Flight Center) and 7) Geo-referencing of MicroMAPS data. An overview of the MicroMAPS project partnership will be presented and the potential for collaboration between federal laboratories and industry with National Space Grant Consortia and their Space Grant universities on similar partnerships will be described.

  20. The holistic analysis of gamma-ray spectra in instrumental neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Blaauw, Menno

    1994-12-01

    A method for the interpretation of γ-ray spectra as obtained in INAA using linear least squares techniques is described. Results obtained using this technique and the traditional method previously in use at IRI are compared. It is concluded that the method presented performs better with respect to the number of detected elements, the resolution of interferences and the estimation of the accuracies of the reported element concentrations. It is also concluded that the technique is robust enough to obviate the deconvolution of multiplets.

  1. Visual Inference Programming

    NASA Technical Reports Server (NTRS)

    Wheeler, Kevin; Timucin, Dogan; Rabbette, Maura; Curry, Charles; Allan, Mark; Lvov, Nikolay; Clanton, Sam; Pilewskie, Peter

    2002-01-01

    The goal of visual inference programming is to develop a software framework data analysis and to provide machine learning algorithms for inter-active data exploration and visualization. The topics include: 1) Intelligent Data Understanding (IDU) framework; 2) Challenge problems; 3) What's new here; 4) Framework features; 5) Wiring diagram; 6) Generated script; 7) Results of script; 8) Initial algorithms; 9) Independent Component Analysis for instrument diagnosis; 10) Output sensory mapping virtual joystick; 11) Output sensory mapping typing; 12) Closed-loop feedback mu-rhythm control; 13) Closed-loop training; 14) Data sources; and 15) Algorithms. This paper is in viewgraph form.

  2. Causal relationship between obesity and vitamin D status: bi-directional Mendelian randomization analysis of multiple cohorts.

    PubMed

    Vimaleswaran, Karani S; Berry, Diane J; Lu, Chen; Tikkanen, Emmi; Pilz, Stefan; Hiraki, Linda T; Cooper, Jason D; Dastani, Zari; Li, Rui; Houston, Denise K; Wood, Andrew R; Michaëlsson, Karl; Vandenput, Liesbeth; Zgaga, Lina; Yerges-Armstrong, Laura M; McCarthy, Mark I; Dupuis, Josée; Kaakinen, Marika; Kleber, Marcus E; Jameson, Karen; Arden, Nigel; Raitakari, Olli; Viikari, Jorma; Lohman, Kurt K; Ferrucci, Luigi; Melhus, Håkan; Ingelsson, Erik; Byberg, Liisa; Lind, Lars; Lorentzon, Mattias; Salomaa, Veikko; Campbell, Harry; Dunlop, Malcolm; Mitchell, Braxton D; Herzig, Karl-Heinz; Pouta, Anneli; Hartikainen, Anna-Liisa; Streeten, Elizabeth A; Theodoratou, Evropi; Jula, Antti; Wareham, Nicholas J; Ohlsson, Claes; Frayling, Timothy M; Kritchevsky, Stephen B; Spector, Timothy D; Richards, J Brent; Lehtimäki, Terho; Ouwehand, Willem H; Kraft, Peter; Cooper, Cyrus; März, Winfried; Power, Chris; Loos, Ruth J F; Wang, Thomas J; Järvelin, Marjo-Riitta; Whittaker, John C; Hingorani, Aroon D; Hyppönen, Elina

    2013-01-01

    Obesity is associated with vitamin D deficiency, and both are areas of active public health concern. We explored the causality and direction of the relationship between body mass index (BMI) and 25-hydroxyvitamin D [25(OH)D] using genetic markers as instrumental variables (IVs) in bi-directional Mendelian randomization (MR) analysis. We used information from 21 adult cohorts (up to 42,024 participants) with 12 BMI-related SNPs (combined in an allelic score) to produce an instrument for BMI and four SNPs associated with 25(OH)D (combined in two allelic scores, separately for genes encoding its synthesis or metabolism) as an instrument for vitamin D. Regression estimates for the IVs (allele scores) were generated within-study and pooled by meta-analysis to generate summary effects. Associations between vitamin D scores and BMI were confirmed in the Genetic Investigation of Anthropometric Traits (GIANT) consortium (n = 123,864). Each 1 kg/m(2) higher BMI was associated with 1.15% lower 25(OH)D (p = 6.52×10⁻²⁷). The BMI allele score was associated both with BMI (p = 6.30×10⁻⁶²) and 25(OH)D (-0.06% [95% CI -0.10 to -0.02], p = 0.004) in the cohorts that underwent meta-analysis. The two vitamin D allele scores were strongly associated with 25(OH)D (p≤8.07×10⁻⁵⁷ for both scores) but not with BMI (synthesis score, p = 0.88; metabolism score, p = 0.08) in the meta-analysis. A 10% higher genetically instrumented BMI was associated with 4.2% lower 25(OH)D concentrations (IV ratio: -4.2 [95% CI -7.1 to -1.3], p = 0.005). No association was seen for genetically instrumented 25(OH)D with BMI, a finding that was confirmed using data from the GIANT consortium (p≥0.57 for both vitamin D scores). On the basis of a bi-directional genetic approach that limits confounding, our study suggests that a higher BMI leads to lower 25(OH)D, while any effects of lower 25(OH)D increasing BMI are likely to be small. Population level interventions to reduce BMI are expected to decrease the prevalence of vitamin D deficiency.

  3. The Development of a Physical Education Teachers' Physical Activity Self-Efficacy Instrument.

    ERIC Educational Resources Information Center

    Martin, Jeffrey J.; Kulinna, Pamela Hodges

    2003-01-01

    Developed a valid, reliable physical education teachers' physical activity self-efficacy scale for teaching classes in which students were engaged in high levels of physical activity. Results offer preliminary support for the psychometric properties of this instrument, which can help understand physical education teachers' efficacy in overcoming…

  4. Physics Thematic Paths: Laboratorial Activities and Historical Scientific Instruments

    ERIC Educational Resources Information Center

    Pantano, O.; Talas, S.

    2010-01-01

    The Physics Department of Padua University keeps an important collection of historical physics instruments which alludes to the fruitful scientific activity of Padua through the centuries. This heritage led to the suggestion of setting up laboratory activities connected to the Museum collection for secondary school students. This article shows how…

  5. Determinants of job stress in chemical process industry: A factor analysis approach.

    PubMed

    Menon, Balagopal G; Praveensal, C J; Madhu, G

    2015-01-01

    Job stress is one of the active research domains in industrial safety research. The job stress can result in accidents and health related issues in workers in chemical process industries. Hence it is important to measure the level of job stress in workers so as to mitigate the same to avoid the worker's safety related problems in the industries. The objective of this study is to determine the job stress factors in the chemical process industry in Kerala state, India. This study also aims to propose a comprehensive model and an instrument framework for measuring job stress levels in the chemical process industries in Kerala, India. The data is collected through a questionnaire survey conducted in chemical process industries in Kerala. The collected data out of 1197 surveys is subjected to principal component and confirmatory factor analysis to develop the job stress factor structure. The factor analysis revealed 8 factors that influence the job stress in process industries. It is also found that the job stress in employees is most influenced by role ambiguity and the least by work environment. The study has developed an instrument framework towards measuring job stress utilizing exploratory factor analysis and structural equation modeling.

  6. Perspectives for on-line analysis of bauxite by neutron irradiation

    NASA Astrophysics Data System (ADS)

    Beurton, Gabriel; Ledru, Bertrand; Letourneur, Philippe

    1995-03-01

    The interest in bauxite as a major source of alumina results in a strong demand for on-line instrumentation suitable for sorting, blending, and processing operations at the bauxite mine and for monitoring instrumentation in the Bayer process. The results of laboratory experiments based on neutron interactions with bauxite are described. The technique was chosen in order to overcome the problem of spatial heterogeneity in bulk mineral analysis. The evaluated elements contributed to approximately 99.5% of the sample weight. In addition, the measurements provide valuable information on physical parameters such as density, hygrometry, and material flow. Using a pulsed generator, the analysis system offers potential for on-line measurements (borehole logging or conveyor belt). An overall description of the experimental set-up is given. The experimental data include measurements of natural radioactivity, delayed radioactivity induced by activation, and prompt gamma rays following neutron reaction. In situ applications of neutron interactions provide continuous analysis and produce results which are more statistically significant. The key factors contributing to advances in industrial applications are the development of high count rate gamma spectroscopy and computational tools to design measurement systems and interpret their results.

  7. Pressure-Assisted Chelating Extraction as a Teaching Tool in Instrumental Analysis

    ERIC Educational Resources Information Center

    Sadik, Omowunmi A.; Wanekaya, Adam K.; Yevgeny, Gelfand

    2004-01-01

    A novel instrumental-digestion technique using pressure-assisted chelating extraction (PACE), for undergraduate laboratory is reported. This procedure is used for exposing students to safe sample-preparation techniques, for correlating wet-chemical methods with modern instrumental analysis and comparing the performance of PACE with conventional…

  8. Space-borne survey instrument operations: lessons learned and new concepts for the Euclid NISP instrument

    NASA Astrophysics Data System (ADS)

    Valenziano, L.; Gregorio, A.; Butler, R. C.; Amiaux, J.; Bonoli, C.; Bortoletto, F.; Burigana, C.; Corcione, L.; Ealet, A.; Frailis, M.; Jahnke, K.; Ligori, S.; Maiorano, E.; Morgante, G.; Nicastro, L.; Pasian, F.; Riva, M.; Scaramella, R.; Schiavone, F.; Tavagnacco, D.; Toledo-Moreo, R.; Trifoglio, M.; Zacchei, A.; Zerbi, F. M.; Maciaszek, T.

    2012-09-01

    Euclid is the future ESA mission, mainly devoted to Cosmology. Like WMAP and Planck, it is a survey mission, to be launched in 2019 and injected in orbit far away from the Earth, for a nominal lifetime of 7 years. Euclid has two instruments on-board, the Visible Imager (VIS) and the Near- Infrared Spectro-Photometer (NISP). The NISP instrument includes cryogenic mechanisms, active thermal control, high-performance Data Processing Unit and requires periodic in-flight calibrations and instrument parameters monitoring. To fully exploit the capability of the NISP, a careful control of systematic effects is required. From previous experiments, we have built the concept of an integrated instrument development and verification approach, where the scientific, instrument and ground-segment expertise have strong interactions from the early phases of the project. In particular, we discuss the strong integration of test and calibration activities with the Ground Segment, starting from early pre-launch verification activities. We want to report here the expertise acquired by the Euclid team in previous missions, only citing the literature for detailed reference, and indicate how it is applied in the Euclid mission framework.

  9. Time variations of solar UV irradiance as measured by the SOLSTICE (UARS) instrument

    NASA Technical Reports Server (NTRS)

    London, Julius; Rottman, Gary J.; Woods, Thomas N.; Wu, Fie

    1993-01-01

    An analysis is presented of solar ultraviolet irradiance measurements made by the SOLSTICE spectrometers on the Upper Atmosphere Research Satellite (UARS). Reported observations cover the wavelength interval 119-420 nm, and the analysis discussed here is for the time period 26 Nov 1991 to 31 Dec 1992, during which time solar activity decreased in intensity. At the time of peak activity, the average 27-day variation had a relative amplitude of about 8 percent at Ly-alpha, tailing off to about 0.6 percent at 260 nm. It is shown that over the spectral interval 119-260 nm, the relative 27-day harmonic was about a factor of two larger during the strongly disturbed as compared with the moderately disturbed period.

  10. γγ coincidence spectrometer for instrumental neutron-activation analysis

    NASA Astrophysics Data System (ADS)

    Tomlin, B. E.; Zeisler, R.; Lindstrom, R. M.

    2008-05-01

    Neutron-activation analysis (NAA) is an important technique for the accurate and precise determination of trace and ultra-trace elemental compositions. The application of γγ coincidence counting to NAA in order to enhance specificity was first explored over 40 years ago but has not evolved into a regularly used technique. A γγ coincidence spectrometer has been constructed at the National Institute of Standards and Technology, using two HPGe γ-ray detectors and an all-digital data-acquisition system, for the purpose of exploring coincidence NAA and its value in characterizing reference materials. This paper describes the initial evaluation of the quantitative precision of coincidence counting versus singles spectrometry, based upon a sample of neutron-irradiated bovine liver material.

  11. Developing and testing a positive theory of instrument choice: Renewable energy policy in the fifty American states

    NASA Astrophysics Data System (ADS)

    Ciocirlan, Cristina E.

    The environmental economics literature consistently suggests that properly designed and implemented economic incentives are superior to command-and-control regulation in reducing pollution. Economic incentives, such as green taxes, cap-and-trade programs, tax incentives, are able to reduce pollution in a cost-effective manner, provide flexibility to industry and stimulate innovation in cleaner technologies. In the past few decades, both federal and state governments have shown increased use of economic incentives in environmental policy. Some states have embraced them in an active manner, while others have failed to do so. This research uses a three-step analysis. First, it asks why some states employ more economic incentives than others to stimulate consumption of renewable energy by the residential, commercial and industrial sectors. Second, it asks why some states employ stronger incentives than others. And third, it asks why certain states employ certain instruments, such as electricity surcharges, cap-and-trade programs, tax incentives or grants, while others do not. The first two analyses were conducted using factor analysis and multiple regression analysis, while the third analysis employed logistic regression models to analyze the data. Data for all three analyses were obtained from a combination of primary and secondary sources. To address these questions, a theory of instrument choice at the state level, which includes both internal and external determinants of policy-making, was developed and tested. The state level of analysis was chosen. States have proven to be pioneers in designing policies to address greenhouse gases (see, for instance, the recent cap-and-trade legislation passed in California). The theory was operationalized with the help of four models: needs/responsiveness, interest group influence, professionalism/capacity and innovation-and-diffusion. The needs/responsiveness model suggests that states tend to choose more and stronger economic incentives when they are more dependent on conventional sources of energy, such as coal, oil and gas or when they have the potential to produce renewable energy. The interest group influence model suggests that instrument choice is ultimately a political decision, most likely to benefit some groups more than others. The professionalism/capacity model posits that states with more professional legislatures, with legislators who make more use of policy analysis, with more capacity to generate nonpartisan policy research and with larger agencies tend to employ more and stronger instruments to stimulate renewable energy consumption and production. And last, the innovation-and-diffusion model suggests that states with a proven innovation record in climate change tend to employ more and stronger economic incentives than states without such record. Also, this model explains states' instrument choice decisions as a function of the choices made by their neighbors.

  12. Dopamine efflux in the nucleus accumbens during within-session extinction, outcome-dependent, and habit-based instrumental responding for food reward.

    PubMed

    Ahn, Soyon; Phillips, Anthony G

    2007-04-01

    Dopamine (DA) activity in the nucleus accumbens (NAc) is related to the general motivational effects of rewarding stimuli. Dickinson and colleagues have shown that initial acquisition of instrumental responding reflects action-outcome relationships based on instrumental incentive learning, which establishes the value of an outcome. Given that the sensitivity of responding to outcome devaluation is not affected by NAc lesions, it is unlikely that incentive learning during the action-outcome phase is mediated by DA activity in the NAc. DA efflux in the NAc after limited and extended training was compared on the assumption that comparable changes would be observed during both action-outcome- and habit-based phases of instrumental responding for food. This study also tested the hypothesis that increase in NAc DA activity is correlated with instrumental responding during extinction maintained by a conditioned stimulus paired with food. Rats were trained to lever press for food (random-interval 30 s schedule). On the 5th and 16th day of training, microdialysis samples were collected from the NAc or mediodorsal striatum (a control site for generalized activity) during instrumental responding in extinction and then for food reward, and analyzed for DA content using high performance liquid chromatography. Increase in DA efflux in the NAc accompanied responding for food pellets on both days 5 and 16, with the magnitude of increase significantly enhanced on day 16. DA efflux was also significantly elevated during responding in extinction only on day 16. These results support a role for NAc DA activity in Pavlovian, but not instrumental, incentive learning.

  13. EGSE customization for the Euclid NISP Instrument AIV/AIT activities

    NASA Astrophysics Data System (ADS)

    Franceschi, E.; Trifoglio, M.; Gianotti, F.; Conforti, V.; Andersen, J. J.; Stephen, J. B.; Valenziano, L.; Auricchio, N.; Bulgarelli, A.; De Rosa, A.; Fioretti, V.; Maiorano, E.; Morgante, G.; Nicastro, L.; Sortino, F.; Zoli, A.; Balestra, A.; Bonino, D.; Bonoli, C.; Bortoletto, F.; Capobianco, V.; Corcione, L.; Dal Corso, F.; Debei, S.; Di Ferdinando, D.; Dusini, S.; Farinelli, R.; Fornari, F.; Giacomini, F.; Guizzo, G. P.; Laudisio, F.; Ligori, S.; Mauri, N.; Medinaceli, E.; Patrizii, L.; Sirignano, C.; Sirri, G.; Stanco, L.; Tenti, M.; Valieri, C.; Ventura, S.

    2016-07-01

    The Near Infrared Spectro-Photometer (NISP) on board the Euclid ESA mission will be developed and tested at various levels of integration by using various test equipment. The Electrical Ground Support Equipment (EGSE) shall be required to support the assembly, integration, verification and testing (AIV/AIT) and calibration activities at instrument level before delivery to ESA, and at satellite level, when the NISP instrument is mounted on the spacecraft. In the case of the Euclid mission this EGSE will be provided by ESA to NISP team, in the HW/SW framework called "CCS Lite", with a possible first usage already during the Warm Electronics (WE) AIV/AIT activities. In this paper we discuss how we will customize that "CCS Lite" as required to support both the WE and Instrument test activities. This customization will primarily involve building the NISP Mission Information Base (the CCS MIB tables) by gathering the relevant data from the instrument sub-units and validating these inputs through specific tools. Secondarily, it will imply developing a suitable set of test sequences, by using uTOPE (an extension to the TCL scripting language, included in the CCS framework), in order to implement the foreseen test procedures. In addition and in parallel, custom interfaces shall be set up between the CCS and the NI-IWS (the NISP Instrument Workstation, which will be in use at any level starting from the WE activities), and also between the CCS and the TCC (the Telescope Control and command Computer, to be only and specifically used during the instrument level tests).

  14. The dream: a psychodynamically informative instrument.

    PubMed

    Glucksman, M L

    2001-01-01

    The dream is a unique psychodynamically informative instrument for evaluating the subjective correlates of brain activity during REM sleep. These include feelings, percepts, memories, wishes, fantasies, impulses, conflicts, and defenses, as well as images of self and others. Dream analysis can be used in a variety of clinical settings to assist in diagnostic assessment, psychodynamic formulation, evaluation of clinical change, and the management of medically ill patients. Dreams may serve as the initial indicators of transference, resistance, impending crisis, acting-out, conflict resolution, and decision-making. A clinically functional categorization of dreams can facilitate an understanding of psychopathology, psychodynamics, personality structure, and various components of the psychotherapeutic process. Examples of different types of dreams are provided to illustrate their relevance and use in various clinical situations.

  15. A multimodal instrument for real-time in situ study of ultrasound and cavitation mediated drug delivery.

    PubMed

    Bian, Shuning; Seth, Anjali; Daly, Dan; Carlisle, Robert; Stride, Eleanor

    2017-03-01

    The development of a multimodal instrument capable of real-time in situ measurements of cavitation activity and effect in tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments is described here. The instrument features an acoustic arm that can expose phantoms to high-intensity focused-ultrasound while measuring cavitation activity and an optical arm that monitors cavitation effect using confocal microscopy. This combination of modalities allows real-time in situ characterisation of drug delivery in tissue and tissue mimicking phantoms during ultrasound and cavitation mediated drug delivery experiments. A representative result, obtained with a tissue mimicking phantom and acoustically activated droplets, is presented here as a demonstration of the instrument's capabilities and potential applications.

  16. Identification of Gas Components in Lighter by Gas Chromatography: An Experiment of the Undergraduate Instrumental Analysis Laboratory Which Can Be Used with Distance Learning Applications

    ERIC Educational Resources Information Center

    Yavuz, Soner; Morgil, Inci

    2006-01-01

    In the applications of instrumental analysis lessons, advanced instruments with the needed experiments are needed. During the lessons it is a fact that the more experiments are performed, the more learning will be. For this reason, experiments that do not last long and should be performed with more simple instruments and that increase students"…

  17. Recent trends in atomic fluorescence spectrometry towards miniaturized instrumentation-A review.

    PubMed

    Zou, Zhirong; Deng, Yujia; Hu, Jing; Jiang, Xiaoming; Hou, Xiandeng

    2018-08-17

    Atomic fluorescence spectrometry (AFS), as one of the common atomic spectrometric techniques with high sensitivity, simple instrumentation, and low acquisition and running cost, has been widely used in various fields for trace elemental analysis, notably the determination of hydride-forming elements by hydride generation atomic fluorescence spectrometry (HG-AFS). In recent years, the soaring demand of field analysis has significantly promoted the miniaturization of analytical atomic spectrometers or at least instrumental components. Various techniques have also been developed to approach the goal of portable/miniaturized AFS instrumentation for field analysis. In this review, potentially portable/miniaturized AFS techniques, primarily involving advanced instrumental components and whole instrumentation with references since 2000, are summarized and discussed. The discussion mainly includes five aspects: radiation source, atomizer, detector, sample introduction, and miniaturized atomic fluorescence spectrometer/system. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. Clarity: An Open Source Manager for Laboratory Automation

    PubMed Central

    Delaney, Nigel F.; Echenique, José Rojas; Marx, Christopher J.

    2013-01-01

    Software to manage automated laboratories interfaces with hardware instruments, gives users a way to specify experimental protocols, and schedules activities to avoid hardware conflicts. In addition to these basics, modern laboratories need software that can run multiple different protocols in parallel and that can be easily extended to interface with a constantly growing diversity of techniques and instruments. We present Clarity: a laboratory automation manager that is hardware agnostic, portable, extensible and open source. Clarity provides critical features including remote monitoring, robust error reporting by phone or email, and full state recovery in the event of a system crash. We discuss the basic organization of Clarity; demonstrate an example of its implementation for the automated analysis of bacterial growth; and describe how the program can be extended to manage new hardware. Clarity is mature; well documented; actively developed; written in C# for the Common Language Infrastructure; and is free and open source software. These advantages set Clarity apart from currently available laboratory automation programs. PMID:23032169

  19. What matters most? Evidence-based findings of health dimensions affecting the societal preferences for EQ-5D health states.

    PubMed

    Andrade, Monica Viegas; Noronha, Kenya Valeria Micaela de Souza; Maia, Ana Carolina; Kind, Paul

    2013-11-01

    This study analyzes how different health dimensions defined by the EQ-5D-3L instrument affect average individual preferences for health states. This analysis is an important benchmark for the incorporation of health technologies as it takes into consideration Brazilian population preferences in health resource allocation decisions. The EQ-5D instrument defines health in terms of five dimensions (mobility, daily activities, self-care activities, pain/discomfort, and anxiety/depression) each divided into three levels of severity. Data came from a valuation study with 3,362 literate individuals aged between 18 and 64 living in urban areas of Minas Gerais State, Brazil. The main results reveal that health utility decreases as the level of severity increases. With regard to health issues, mobility stands out as the most important EQ-5D dimension. Independently of severity levels of the other EQ-5D-3L dimensions, the highest decrements in utilities are associated with severe mobility problems.

  20. Coronagraph observations and analyses of the ultraviolet solar corona

    NASA Technical Reports Server (NTRS)

    Kohl, John L.

    1989-01-01

    The major activities on the Spartan Ultraviolet Coronal Spectrometer project include both scientific and experimental/technical efforts. In the scientific area, a detailed analysis of the previously reported Doppler dimming of HI Ly-alpha from the July 1982 rocket flight has determined an outflow velocity at 2 solar radii from sun center to be between 153 and 251 km/s at 67 percent confidence. The technical activities include, several improvements made to the instrument that will result in enhanced scientific performance or in regaining a capability that had deteriorated during the delay time in the launch date. These include testing and characterizing the detector for OVI radiation, characterizing a serrated occulter at UV and visible wavelengths, fabricating and testing telescope mirrors with improved edges, testing and evaluating a new array detector system, modifying the slit mask mechanism and installing a mask in the instrument to block the Ly-alpha resonance line when the electron scattered component is being observed.

  1. Cascadia Initiative Ocean Bottom Seismograph Performance

    NASA Astrophysics Data System (ADS)

    Evers, B.; Aderhold, K.

    2017-12-01

    The Ocean Bottom Seismograph Instrument Pool (OBSIP) provided instrumentation and operations support for the Cascadia Initiative community experiment. This experiment investigated geophysical processes across the Cascadia subduction zone through a combination of onshore and offshore seismic data. The recovery of Year 4 instruments in September 2015 marked the conclusion of a multi-year experiment that utilized 60 ocean-bottom seismographs (OBSs) specifically designed for the subduction zone boundary, including shallow/deep water deployments and active fisheries. The new instruments featured trawl-resistant enclosures designed by Lamont-Doherty Earth Observatory (LDEO) and Scripps Institution of Oceanography (SIO) for shallow deployment [water depth ≤ 500 m], as well as new deep-water instruments designed by Woods Hole Oceanographic Institute (WHOI). Existing OBSIP instruments were also deployed along the Blanco Transform Fault and on the Gorda Plate through complementary experiments. Station instrumentation included weak and strong motion seismometers, differential pressure gauges (DPG) and absolute pressure gauges (APG). All data collected from the Cascadia, Blanco, and Gorda deployments is available through the Incorporated Research Institutions for Seismology (IRIS) Data Management Center (DMC). The Cascadia Initiative is the largest amphibious seismic experiment undertaken to date, encompassing a diverse technical implementation and demonstrating an effective structure for community experiments. Thus, the results from Cascadia serve as both a technical and operational resource for the development of future community experiments, such as might be contemplated as part of the SZ4D Initiative. To guide future efforts, we investigate and summarize the quality of the Cascadia OBS data using basic metrics such as instrument recovery and more advanced metrics such as noise characteristics through power spectral density analysis. We also use this broad and diverse deployment to explore other environmental and configuration factors that can impact sensor and network performance and inform the design of future deployments.

  2. Risk taking in first and second generation Afro-Caribbean adolescents: an emerging challenge for school nurses.

    PubMed

    Jolly, Kim; Archibald, Cynthia; Liehr, Patricia

    2013-10-01

    School nurses are well positioned to address risk-taking behaviors for adolescents in their care. The purpose of this mixed-method exploratory study was to explore risk taking in Afro-Caribbean adolescents in South Florida, comparing first- to second-generation adolescents. Quantitative and qualitative data were collected from an immigrant group using the adolescent risk-taking instrument to evaluate risk-taking attitudes, behaviors, and self-described riskiest activities. One-hundred and six adolescents participated; 44% were first generation Afro-Caribbean. Data analysis included analysis of variance, frequencies, and content analysis. There were no differences in risk-taking attitudes; smaller percentages of first generation Afro-Caribbean adolescents reported sexual activity, substance use, and violence. Over one third of the sample, regardless of generational status, reported alcohol use, but did not note alcohol or other health-compromising behaviors as "riskiest" activities. It is important to better understand Afro-Caribbean adolescents' perspectives about risky behaviors, and school-based venues offer the best promise for reaching these adolescents.

  3. Simultaneous control of multiple instruments at the Advanced Technology Solar Telescope

    NASA Astrophysics Data System (ADS)

    Johansson, Erik M.; Goodrich, Bret

    2012-09-01

    The Advanced Technology Solar Telescope (ATST) is a 4-meter solar observatory under construction at Haleakala, Hawaii. The simultaneous use of multiple instruments is one of the unique capabilities that makes the ATST a premier ground based solar observatory. Control of the instrument suite is accomplished by the Instrument Control System (ICS), a layer of software between the Observatory Control System (OCS) and the instruments. The ICS presents a single narrow interface to the OCS and provides a standard interface for the instruments to be controlled. It is built upon the ATST Common Services Framework (CSF), an infrastructure for the implementation of a distributed control system. The ICS responds to OCS commands and events, coordinating and distributing them to the various instruments while monitoring their progress and reporting the status back to the OCS. The ICS requires no specific knowledge about the instruments. All information about the instruments used in an experiment is passed by the OCS to the ICS, which extracts and forwards the parameters to the appropriate instrument controllers. The instruments participating in an experiment define the active instrument set. A subset of those instruments must complete their observing activities in order for the experiment to be considered complete and are referred to as the must-complete instrument set. In addition, instruments may participate in eavesdrop mode, outside of the control of the ICS. All instrument controllers use the same standard narrow interface, which allows new instruments to be added without having to modify the interface or any existing instrument controllers.

  4. Development, validity and reliability of the short multidimensional positive mental health instrument.

    PubMed

    Vaingankar, Janhavi Ajit; Subramaniam, Mythily; Abdin, Edimansyah; Picco, Louisa; Chua, Boon Yiang; Eng, Goi Khia; Sambasivam, Rajeswari; Shafie, Saleha; Zhang, Yunjue; Chong, Siow Ann

    2014-06-01

    The 47-item positive mental health (PMH) instrument measures the level of PMH in multiethnic adult Asian populations. This study aimed to (1) develop a short PMH instrument and (2) establish its validity and reliability among the adult Singapore population. Two separate studies were conducted among adult community-dwelling Singapore residents of Chinese, Malay or Indian ethnicity where participants completed self-administered questionnaires. In the first study, secondary data analysis was conducted using confirmatory factor analysis (CFA) to shorten the PMH instrument. In the second study, the newly developed short PMH instrument and other scales were administered to 201 residents to establish its factor structure, validity and reliability. A 20-item short PMH instrument fulfilling a higher-order six-factor structure was developed following secondary analysis. The mean age of the participants in the second study was 41 years and about 53% were women. One item with poor factor loading was further removed to generate a 19-item version of the PMH instrument. CFA demonstrated a first-order six-factor model of the short PMH instrument. The PMH-19 instrument and its subscales fulfilled criterion validity hypotheses. Internal consistency and test-retest reliability of the PMH-19 instrument were high (Cronbach's α coefficient = 0.87; intraclass correlation coefficient = 0.93, respectively). The 19-item PMH instrument is multidimensional, valid and reliable, and most importantly, with its reduced administration time, the short PMH instrument can be used to measure and evaluate PMH in Asian communities.

  5. Defect propagation in NiTi rotary instruments: a noncontact optical profilometry analysis.

    PubMed

    Barbosa, I; Ferreira, F; Scelza, P; Neff, J; Russano, D; Montagnana, M; Zaccaro Scelza, M

    2018-04-10

    To evaluate the presence and propagation of defects and their effects on surfaces of nickel-titanium (NiTi) instruments using noncontact, three-dimensional optical profilometry, and to assess the accuracy of this method of investigation. The flute surface areas of instruments from two commercial instrumentation systems, namely Reciproc R25 (n = 5) and WaveOne Primary (n = 5), were assessed and compared before and after performing two instrumentation cycles in simulated root canals in clear resin blocks. All the analyses were conducted on areas measuring 211 × 211 μm, located 3 mm from the tips of the instruments. A quantitative analysis was conducted before and after the first and second instrumentation cycles, using the Sa (average roughness over the measurement field), Sq (root mean square roughness) and Sz (average height over the measurement field) amplitude parameters. All the data were submitted to statistical analysis at a 5% level of significance. There was a significant increase (P = 0.007) in wear in both groups, especially between baseline and the second instrumentation cycle, with significantly higher wear values being observed on WaveOne instruments (Sz median values = 33.68 and 2.89 μm, respectively, for WO and RP groups). A significant increase in surface roughness (P = 0.016 and P = 0.008, respectively, for Sa and Sq) was observed in both groups from the first to the second instrumentation cycle, mostly in WaveOne specimens. Qualitative analysis revealed a greater number of defects on the flute topography of all the instruments after use. More defects were identified in WaveOne Primary instruments compared to Reciproc R25, irrespective of the evaluation stage. The investigation method provided an accurate, repeatable and reproducible assessment of NiTi instruments at different time-points. © 2018 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  6. Development and testing of an assessment instrument for the formative peer review of significant event analyses.

    PubMed

    McKay, J; Murphy, D J; Bowie, P; Schmuck, M-L; Lough, M; Eva, K W

    2007-04-01

    To establish the content validity and specific aspects of reliability for an assessment instrument designed to provide formative feedback to general practitioners (GPs) on the quality of their written analysis of a significant event. Content validity was quantified by application of a content validity index. Reliability testing involved a nested design, with 5 cells, each containing 4 assessors, rating 20 unique significant event analysis (SEA) reports (10 each from experienced GPs and GPs in training) using the assessment instrument. The variance attributable to each identified variable in the study was established by analysis of variance. Generalisability theory was then used to investigate the instrument's ability to discriminate among SEA reports. Content validity was demonstrated with at least 8 of 10 experts endorsing all 10 items of the assessment instrument. The overall G coefficient for the instrument was moderate to good (G>0.70), indicating that the instrument can provide consistent information on the standard achieved by the SEA report. There was moderate inter-rater reliability (G>0.60) when four raters were used to judge the quality of the SEA. This study provides the first steps towards validating an instrument that can provide educational feedback to GPs on their analysis of significant events. The key area identified to improve instrument reliability is variation among peer assessors in their assessment of SEA reports. Further validity and reliability testing should be carried out to provide GPs, their appraisers and contractual bodies with a validated feedback instrument on this aspect of the general practice quality agenda.

  7. Resident participation in neighbourhood audit tools — a scoping review

    PubMed Central

    Hofland, Aafke C L; Devilee, Jeroen; van Kempen, Elise; den Broeder, Lea

    2018-01-01

    Abstract Background Healthy urban environments require careful planning and a testing of environmental quality that goes beyond statutory requirements. Moreover, it requires the inclusion of resident views, perceptions and experiences that help deepen the understanding of local (public health) problems. To facilitate this, neighbourhoods should be mapped in a way that is relevant to them. One way to do this is participative neighbourhood auditing. This paper provides an insight into availability and characteristics of participatory neighbourhood audit instruments. Methods A scoping review in scientific and grey literature, consisting of the following steps: literature search, identification and selection of relevant audit instruments, data extraction and data charting (including a work meeting to discuss outputs), reporting. Results In total, 13 participatory instruments were identified. The role of residents in most instruments was as ‘data collectors’; only few instruments included residents in other audit activities like problem definition or analysis of data. The instruments identified focus mainly on physical, not social, neighbourhood characteristics. Paper forms containing closed-ended questions or scales were the most often applied registration method. Conclusions The results show that neighbourhood auditing could be improved by including social aspects in the audit tools. They also show that the role of residents in neighbourhood auditing is limited; however, little is known about how their engagement takes place in practice. Developers of new instruments need to balance not only social and physical aspects, but also resident engagement and scientific robustness. Technologies like mobile applications pose new opportunities for participative approaches in neighbourhood auditing. PMID:29346663

  8. Resident participation in neighbourhood audit tools - a scoping review.

    PubMed

    Hofland, Aafke C L; Devilee, Jeroen; van Kempen, Elise; den Broeder, Lea

    2018-02-01

    Healthy urban environments require careful planning and a testing of environmental quality that goes beyond statutory requirements. Moreover, it requires the inclusion of resident views, perceptions and experiences that help deepen the understanding of local (public health) problems. To facilitate this, neighbourhoods should be mapped in a way that is relevant to them. One way to do this is participative neighbourhood auditing. This paper provides an insight into availability and characteristics of participatory neighbourhood audit instruments. A scoping review in scientific and grey literature, consisting of the following steps: literature search, identification and selection of relevant audit instruments, data extraction and data charting (including a work meeting to discuss outputs), reporting. In total, 13 participatory instruments were identified. The role of residents in most instruments was as 'data collectors'; only few instruments included residents in other audit activities like problem definition or analysis of data. The instruments identified focus mainly on physical, not social, neighbourhood characteristics. Paper forms containing closed-ended questions or scales were the most often applied registration method. The results show that neighbourhood auditing could be improved by including social aspects in the audit tools. They also show that the role of residents in neighbourhood auditing is limited; however, little is known about how their engagement takes place in practice. Developers of new instruments need to balance not only social and physical aspects, but also resident engagement and scientific robustness. Technologies like mobile applications pose new opportunities for participative approaches in neighbourhood auditing. © The Author 2017. Published by Oxford University Press on behalf of the European Public Health Association. All rights reserved.

  9. Intercomparison of active and passive instruments for radon and radon progeny in North America

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- andmore » beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within {plus_minus}10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement.« less

  10. Measurement of affective and activity pain interference using the Brief Pain Inventory (BPI): Cancer and Leukemia Group B 70903.

    PubMed

    Atkinson, Thomas M; Halabi, Susan; Bennett, Antonia V; Rogak, Lauren; Sit, Laura; Li, Yuelin; Kaplan, Ellen; Basch, Ethan

    2012-11-01

    The Brief Pain Inventory (BPI) was designed to yield separate scores for pain intensity and interference. It has been proposed that the pain interference factor can be further broken down into unique factors of affective (e.g., mood) and activity (e.g., work) interference. The purpose of this analysis was to confirm this affective/activity interference dichotomy. A retrospective confirmatory factor analysis was completed for a sample of 184 individuals diagnosed with castrate-resistant prostate cancer (age 40-86, mean = 65.46, 77% White non-Hispanic) who had been administered the BPI as part of Cancer and Leukemia Group B trial 9480. A one-factor model was compared against two-factor and three-factor models that were developed based on the design of the instrument. Root mean squared error of approximation (0.075), comparative fit index (0.971), and change in chi-square, given the corresponding change in degrees of freedom (13.33, P < 0.05) values for the three-factor model (i.e., pain intensity, activity interference, and affective interference), were statistically superior in comparison with the one- and two-factor models. This three-factor structure was found to be invariant across age, mean prostate-specific antigen, and hemoglobin levels. These results confirm that the BPI can be used to quantify the degree to which pain separately interferes with affective and activity aspects of a patient's everyday life. These findings will provide clinical trialists, pharmaceutical sponsors, and regulators with confidence in the flexibility of the BPI as they consider the use of this instrument to assist with understanding the patient experience as it relates to treatment. Wiley Periodicals, Inc.

  11. Development and inter-laboratory validation of unlabeled probe melting curve analysis for detection of JAK2 V617F mutation in polycythemia vera.

    PubMed

    Wu, Zhiyuan; Yuan, Hong; Zhang, Xinju; Liu, Weiwei; Xu, Jinhua; Zhang, Wei; Guan, Ming

    2011-01-01

    JAK2 V617F, a somatic point mutation that leads to constitutive JAK2 phosphorylation and kinase activation, has been incorporated into the WHO classification and diagnostic criteria of myeloid neoplasms. Although various approaches such as restriction fragment length polymorphism, amplification refractory mutation system and real-time PCR have been developed for its detection, a generic rapid closed-tube method, which can be utilized on routine genetic testing instruments with stability and cost-efficiency, has not been described. Asymmetric PCR for detection of JAK2 V617F with a 3'-blocked unlabeled probe, saturate dye and subsequent melting curve analysis was performed on a Rotor-Gene® Q real-time cycler to establish the methodology. We compared this method to the existing amplification refractory mutation systems and direct sequencing. Hereafter, the broad applicability of this unlabeled probe melting method was also validated on three diverse real-time systems (Roche LightCycler® 480, Applied Biosystems ABI® 7500 and Eppendorf Mastercycler® ep realplex) in two different laboratories. The unlabeled probe melting analysis could genotype JAK2 V617F mutation explicitly with a 3% mutation load detecting sensitivity. At level of 5% mutation load, the intra- and inter-assay CVs of probe-DNA heteroduplex (mutation/wild type) covered 3.14%/3.55% and 1.72%/1.29% respectively. The method could equally discriminate mutant from wild type samples on the other three real-time instruments. With a high detecting sensitivity, unlabeled probe melting curve analysis is more applicable to disclose JAK2 V617F mutation than conventional methodologies. Verified with the favorable inter- and intra-assay reproducibility, unlabeled probe melting analysis provided a generic mutation detecting alternative for real-time instruments.

  12. Analysis of electrical transients created by lightning

    NASA Technical Reports Server (NTRS)

    Nanevicz, J. E.; Vance, E. F.

    1980-01-01

    A series of flight tests was conducted using a specially-instrumented NASA Learjet to study the electrical transients created on an aircraft by nearby lightning. The instrumentation included provisions for the time-domain and frequency-domain recording of the electrical signals induced in sensors located both on the exterior and on the interior of the aircraft. The design and calibration of the sensors and associated measuring systems is described together with the results of the flight test measurements. The results indicate that the concept of providing instrumentation to follow the lightning signal from propagation field, to aircraft skin current, to current on interior wiring is basically sound. The results of the measurement indicate that the high frequency signals associated with lightning stroke precursor activity are important in generating electromagnetic noise on the interior of the aircraft. Indeed, the signals produced by the precursors are often of higher amplitude and of longer duration that the pulse produced by the main return stroke.

  13. PPI/HASI Pressure Measurements in the Atmosphere of Titan

    NASA Astrophysics Data System (ADS)

    M'akinen, J. T. T.; Harri, A.-M.; Siili, T.; Lehto, A.; Kahanp'a'a, H.; Genzer, M.; Leppelmeier, G. W.; Leinonen, J.

    2005-08-01

    The Huygens probe descended through the atmosphere of Titan on January 14, 2005, providing an excellent set of observations. As a part of the Huygens Atmospheric Structure Instrument (HASI) measuring several variables, including acceleration, pressure, temperature and atmospheric electricity, the Pressure Profile Instrument (PPI) provided by FMI commenced operations after the deployment of the main parachute and jettisoning of the heat shield at an altitude of about 160 km. Based on aerodynamic considerations, PPI measured the total pressure with a Kiel probe at the end of a boom, connected to the sensor electronics inside the probe through an inlet tube. The instrument performed flawlessly during the 2.5 hour descent and the 0.5 hour surface phase before the termination of radio link between Huygens and the Cassini orbiter. We present an analysis of the pressure data including recreation of the pressure, temperature, altitude, velocity and acceleration profiles as well as an estimate for the level of atmospheric activity on the surface of Titan.

  14. The Mars oxidant experiment (MOx) for Mars '96

    NASA Technical Reports Server (NTRS)

    McKay, C. P.; Grunthaner, F. J.; Lane, A. L.; Herring, M.; Bartman, R. K.; Ksendzov, A.; Manning, C. M.; Lamb, J. L.; Williams, R. M.; Ricco, A. J.; hide

    1998-01-01

    The MOx instrument was developed to characterize the reactive nature of the martian soil. The objectives of MOx were: (1) to measure the rate of degradation of organics in the martian environment; (2) to determine if the reactions seen by the Viking biology experiments were caused by a soil oxidant and measure the reactivity of the soil and atmosphere: (3) to monitor the degradation, when exposed to the martian environment, of materials of potential use in future missions; and, finally, (4) to develop technologies and approaches that can be part of future soil analysis instrumentation. The basic approach taken in the MOx instrument was to place a variety of materials composed as thin films in contact with the soil and monitor the physical and chemical changes that result. The optical reflectance of the thin films was the primary sensing-mode. Thin films of organic materials, metals, and semiconductors were prepared. Laboratory simulations demonstrated the response of thin films to active oxidants.

  15. Thermodynamic performance of the 3-stage ADR for the Astro-H Soft-X-ray Spectrometer instrument

    NASA Astrophysics Data System (ADS)

    Shirron, Peter J.; Kimball, Mark O.; James, Bryan L.; Muench, Theodore; DiPirro, Michael J.; Bialas, Thomas G.; Sneiderman, Gary A.; Porter, Frederick S.; Kelley, Richard L.

    2016-03-01

    The Soft X-ray Spectrometer (SXS) instrument (Mitsuda et al., 2010) [1] on Astro-H (Takahashi et al., 2010) [2] will use a 3-stage ADR (Shirron et al., 2012) to cool the microcalorimeter array to 50 mK. In the primary operating mode, two stages of the ADR cool the detectors using superfluid helium at ⩽1.20 K as the heat sink (Fujimoto et al., 2010). In the secondary mode, which is activated when the liquid helium is depleted, the ADR uses a 4.5 K Joule-Thomson cooler as its heat sink. In this mode, all three stages operate together to continuously cool the (empty) helium tank and single-shot cool the detectors. The flight instrument - dewar, ADR, detectors and electronics - were integrated in 2014 and have since undergone extensive performance testing. This paper presents a thermodynamic analysis of the ADR's operation, including cooling capacity, heat rejection to the heat sinks, and various measures of efficiency.

  16. Cross-cultural validation of a simple self-report instrument of physical activity in immigrants from the Middle East and native Swedes.

    PubMed

    Arvidsson, Daniel; Leijon, Matti; Sundquist, Jan; Sundquist, Kristina; Lindblad, Ulf; Bennet, Louise

    2014-05-01

    To investigate cross-cultural validity of a simple self-report instrument of physical activity intended to be used in Swedish health care. A validation study performed in 599 Iraqis (58% men) and 553 Swedes (53% men) aged 30-75 years living in the city of Malmö, Sweden. The self-report instrument by the Swedish National Board of Health and Welfare was compared to corresponding measures assessed from accelerometry as reference. The agreement between the methods in assessing the participants as sufficiently/insufficiently physically active (cut-point 150 min/week) was 65% in the Iraqis and 52% in the Swedes (p<0.001). The proportion disagreement where the self-reported physical activity was sufficient but insufficient according to the accelerometry was 26% and 45% in Iraqis and Swedes, respectively. Physical activity time (min/week) was overestimated by self-report compared to accelerometry by 71% in the Iraqis and 115% in the Swedes (p<0.001). The smallest and largest overestimation was seen in Iraqi (57%) and Swedish (139%) women, respectively. The deviation of the self-report instrument compared to accelerometry was related to the physical activity level, as the overestimation mainly occurred at lower physical activity. The self-report instrument proposed by the Swedish National Board of Health and Welfare may overestimate the proportion sufficiently physically active, but to an extent depending on cultural background and gender.

  17. Development of scales relating to professional development of community college administrators.

    PubMed

    Wolfe, Edward W; Van Der Linden, Kim E

    2010-01-01

    This article reports the results of an application of the Multidimensional Random Coefficients Multinomial Logit Model (MRCMLM) to the measurement of professional development activities in which community college administrators participate. The analyses focus on confirmation of the factorial structure of the instrument, evaluation of the quality of the activities calibrations, examination of the internal structure of the instrument, and comparison of groups of administrators. The dimensionality analysis results suggest a five-dimensional model that is consistent with previous literature concerning career paths of community college administrators - education and specialized training, internal professional development and mentoring, external professional development, employer support, and seniority. The indicators of the quality of the activity calibrations suggest that measures of the five dimensions are adequately reliable, that the activities in each dimension are internally consistent, and that the observed responses to each activity are consistent with the expected values of the MRCMLM. The hierarchy of administrator measure means and of activity calibrations is consistent with substantive theory relating to professional development for community college administrators. For example, readily available activities that occur at the institution were most likely to be engaged in by administrators, while participation in selective specialized training institutes were the least likely activities. Finally, group differences with respect to age and title were consistent with substantive expectations - the greater the administrator's age and the higher the rank of the administrator's title, the greater the probability of having engaged in various types of professional development.

  18. Comparison of mechanical energy profiles of passive and active below-knee prostheses: a case study.

    PubMed

    Takahashi, Kota Z; Horne, John R; Stanhope, Steven J

    2015-04-01

    With the recent technological advancements of prosthetic lower limbs, there is currently a great desire to objectively evaluate existing prostheses. Using a novel biomechanical analysis, the purpose of this case study was to compare the mechanical energy profiles of anatomical and two disparate prostheses: a passive prosthesis and an active prosthesis. An individual with a transtibial amputation who customarily wears a passive prosthesis (Elation, Össur) and an active prosthesis (BiOM, iWalk, Inc.) and 11 healthy subjects participated in an instrumented gait analysis. The total mechanical power and work of below-knee structures during stance were quantified using a unified deformable segment power analysis. Active prosthesis generated greater peak power and total positive work than passive prosthesis and healthy anatomical limbs. The case study will enhance future efforts to objectively evaluate prosthetic functions during gait in individuals with transtibial amputations. A prosthetic limb should closely replicate the mechanical energy profiles of anatomical limbs. The unified deformable (UD) analysis may be valuable to facilitate future clinical prescription and guide fine adjustments of prosthetic componentry to optimize gait outcomes. © The International Society for Prosthetics and Orthotics 2014.

  19. Active spacecraft potential control: An ion emitter experiment. [Cluster mission

    NASA Technical Reports Server (NTRS)

    Riedler, W.; Goldstein, R.; Hamelin, M.; Maehlum, B. N.; Troim, J.; Olsen, R. C.; Pedersen, A.; Grard, R. J. L.; Schmidt, R.; Rudenauer, F.

    1988-01-01

    The cluster spacecraft are instrumented with ion emitters for charge neutralization. The emitters produce indium ions at 6 keV. The ion current is adjusted in a feedback loop with instruments measuring the spacecraft potential. The system is based on the evaporation of indium in the apex field of a needle. The design of the active spacecraft potential control instruments, and the ion emitters is presented.

  20. Interventional magnetic resonance angiography with no strings attached: wireless active catheter visualization.

    PubMed

    Quick, Harald H; Zenge, Michael O; Kuehl, Hilmar; Kaiser, Gernot; Aker, Stephanie; Massing, Sandra; Bosk, Silke; Ladd, Mark E

    2005-02-01

    Active instrument visualization strategies for interventional MR angiography (MRA) require vascular instruments to be equipped with some type of radiofrequency (RF) coil or dipole RF antenna for MR signal detection. Such visualization strategies traditionally necessitate a connection to the scanner with either coaxial cable or laser fibers. In order to eliminate any wire connection, RF resonators that inductively couple their signal to MR surface coils were implemented into catheters to enable wireless active instrument visualization. Instrument background to contrast-to-noise ratio was systematically investigated as a function of the excitation flip angle. Signal coupling between the catheter RF coil and surface RF coils was evaluated qualitatively and quantitatively as a function of the catheter position and orientation with regard to the static magnetic field B0 and to the surface coils. In vivo evaluation of the instruments was performed in interventional MRA procedures on five pigs under MR guidance. Cartesian and projection reconstruction TrueFISP imaging enabled simultaneous visualization of the instruments and vascular morphology in real time. The implementation of RF resonators enabled robust visualization of the catheter curvature to the very tip. Additionally, the active visualization strategy does not require any wire connection to the scanner and thus does not hamper the interventionalist during the course of an intervention.

  1. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    George, A.C.; Knutson, E.O.; Tu, K.W.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC).more » There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is <5,000 cm{sup -3}.« less

  2. Trace element analysis of soil type collected from the Manjung and central Perak

    NASA Astrophysics Data System (ADS)

    Azman, Muhammad Azfar; Hamzah, Suhaimi; Rahman, Shamsiah Abdul; Elias, Md Suhaimi; Abdullah, Nazaratul Ashifa; Hashim, Azian; Shukor, Shakirah Abd; Kamaruddin, Ahmad Hasnulhadi Che

    2015-04-01

    Trace elements in soils primarily originated from their parent materials. Parents' material is the underlying geological material that has been undergone different types of chemical weathering and leaching processes. Soil trace elements concentrations may be increases as a result of continuous input from various human activities, including power generation, agriculture, mining and manufacturing. This paper describes the Neutron Activation Analysis (NAA) method used for the determination of trace elements concentrations in part per million (ppm) present in the terrestrial environment soil in Perak. The data may indicate any contamination of trace elements contributed from human activities in the area. The enrichment factors were used to check if there any contamination due to the human activities (power plants, agricultural, mining, etc.) otherwise the values would serve as a baseline data for future study. The samples were collected from 27 locations of different soil series in the area at two different depths: the top soil (0-15cm) and the sub soil (15-30cm). The collected soil samples were air dried at 60°C and passed through 2 µm sieve. Instrumental Neutron Activation Analysis (NAA) has been used for the determination of trace elements. Samples were activated in the Nuclear Malaysia TRIGA Mark II reactor followed by gamma spectrometric analysis. By activating the stable elements in the samples, the elements can be determined from the intensities of gamma energies emitted by the respected radionuclides.

  3. Probing the atmosphere of a sub-Jovian planet orbiting a cool dwarf

    NASA Astrophysics Data System (ADS)

    Sedaghati, Elyar; Boffin, Henri M. J.; Delrez, Laetitia; Gillon, Michaël; Csizmadia, Szilard; Smith, Alexis M. S.; Rauer, Heike

    2017-07-01

    We derive the 0.01-μm binned transmission spectrum, between 0.74 and 1.0 μm, of WASP-80b from low-resolution spectra obtained with the Focal Reducer and low-dispersion Spectrograph 2 instrument attached to ESO's Very Large Telescope. The combination of the fact that WASP-80 is an active star, together with instrumental and telluric factors, introduces correlated noise in the observed transit light curves, which we treat quantitatively using Gaussian processes. Comparison of our results together with those from previous studies to theoretically calculated models reveals an equilibrium temperature in agreement with the previously measured value of 825 K, and a subsolar metallicity, as well as an atmosphere depleted of molecular species with absorption bands in the infrared (≫5σ). Our transmission spectrum alone shows evidence for additional absorption from the potassium core and wing, whereby its presence is detected from analysis of narrow 0.003 μm bin light curves (≫5σ). Further observations with visible and near-ultraviolet filters will be required to expand this spectrum and provide more in-depth knowledge of the atmosphere. These detections are only made possible through an instrument-dependent baseline model and a careful analysis of systematics in the data.

  4. Mass analysis addition to the Differential Ion Flux Probe (DIFP) study

    NASA Technical Reports Server (NTRS)

    Wright, K. H., Jr.; Jolley, Richard

    1994-01-01

    The objective of this study is to develop a technique to measure the characteristics of space plasmas under highly disturbed conditions; e.g., non-Maxwellian plasmas with strong drifting populations and plasmas contaminated by spacecraft outgassing. The approach, conducted in conjunction with current MSFC activities, is to extend the capabilities of the Differential Ion Flux Probe (DIFP) to include a high throughput mass measurement that does not require either high voltage or contamination sensitive devices such as channeltron electron multipliers or microchannel plates. This will significantly reduce the complexity and expense of instrument fabrication, testing, and integration of flight hardware compared to classical mass analyzers. The feasibility of the enhanced DIFP has been verified by using breadboard test models in a controlled plasma environment. The ability to manipulate particles through the instrument regardless of incident angle, energy, or ionic component has been amply demonstrated. The energy analysis mode is differential and leads directly to a time-of-flight mass measurement. With the new design, the DIFP will separate multiple ion streams and analyze each stream independently for ion flux intensity, velocity (including direction of motion), mass, and temperature (or energy distribution). In particular, such an instrument will be invaluable on follow-on electrodynamic TSS missions and, possibly, for environmental monitoring on the space station.

  5. [The movement computerized analysis as instrumental support for occupational doctors in evaluation of upper limb pathologies in engineering workers].

    PubMed

    D'Orso, M I; Centemeri, R; Oggionni, P; Latocca, R; Crippa, M; Vercellino, R; Riva, M; Cesana, G

    2011-01-01

    The movement computerized analysis of upper limb is a valid support in the definition of residual functional capability and of specific work suitability in complex cases. This methodology of evaluation is able to correctly and objectively define the tridimensional ranges of motion of every patient's upper limb. This fact can be particularly useful for workers coming back to work after a work-related or a not work-related accident of for handicapped workers at the beginning of a new work activity. We report a research carried out using computerized analysis of motion of upper limbs in 20 engineering workers.

  6. Factor structure of the Korean version of illness intrusiveness rating scale: cross-cultural implications.

    PubMed

    Kim, Daeho; Kim, Kwang-iel; Lee, Haewon; Choi, Joonho; Park, Yong-Chon

    2005-04-01

    The Illness Intrusiveness Rating Scale (IIRS) measures illness-induced disruptions to 13 domains of lifestyles, activities, and interests. A stable three-factor structure has been well documented; however, the cross-cultural validity of this scale needs to be tested. This study investigated the factor structure of the Korean version of IIRS in 712 outpatients at a university medical center. A predominant diagnosis of the patients was rheumatoid arthritis (47%). The Center for Epidemiological Studies-Depression Scale (CES-D), and Health Assessment Questionnaire (HAQ) were also administered. Exploratory Principal Component Analysis identified a two-factor structure, "Relationships and Personal Development (RPD)" and "Instrumental", accounting for 57% of the variance. Confirmatory analyses extracted an identical factor structure. However, a goodness-of-the fit test failed to support two-factor solution (chi(2)=138.2, df=43, p<.001). Two factors had high internal consistency (RPD, alpha=.89; Instrumental, alpha=.75) and significantly correlated with scores of HAQ (RPD, r=.53, p<.001; Instrumental, .r=44, p<.001) and CES-D (RPD, .r=55, p<.001; Instrumental, .r=43, p<.001). These findings supported construct validity of the Korean version of IIRS, but did not support cross-cultural equivalence of the factor structure.

  7. Dissociations among functional subsystems governing melody recognition after right-hemisphere damage.

    PubMed

    Steinke, W R; Cuddy, L L; Jakobson, L S

    2001-07-01

    This study describes an amateur musician, KB, who became amusic following a right-hemisphere stroke. A series of assessments conducted post-stroke revealed that KB functioned in the normal range for most verbal skills. However, compared with controls matched in age and music training, KB showed severe loss of pitch and rhythmic processing abilities. His ability to recognise and identify familiar instrumental melodies was also lost. Despite these deficits, KB performed remarkably well when asked to recognise and identify familiar song melodies presented without accompanying lyrics. This dissociation between the ability to recognise/identify song vs. instrumental melodies was replicated across different sets of musical materials, including newly learned melodies. Analyses of the acoustical and musical features of song and instrumental melodies discounted an explanation of the dissociation based on these features alone. Rather, the results suggest a functional dissociation resulting from a focal brain lesion. We propose that, in the case of song melodies, there remains sufficient activation in KB's melody analysis system to coactivate an intact representation of both associative information and the lyrics in the speech lexicon, making recognition and identification possible. In the case of instrumental melodies, no such associative processes exist; thus recognition and identification do not occur.

  8. MAHLI on Mars: lessons learned operating a geoscience camera on a landed payload robotic arm

    NASA Astrophysics Data System (ADS)

    Aileen Yingst, R.; Edgett, Kenneth S.; Kennedy, Megan R.; Krezoski, Gillian M.; McBride, Marie J.; Minitti, Michelle E.; Ravine, Michael A.; Williams, Rebecca M. E.

    2016-06-01

    The Mars Hand Lens Imager (MAHLI) is a 2-megapixel, color camera with resolution as high as 13.9 µm pixel-1. MAHLI has operated successfully on the Martian surface for over 1150 Martian days (sols) aboard the Mars Science Laboratory (MSL) rover, Curiosity. During that time MAHLI acquired images to support science and science-enabling activities, including rock and outcrop textural analysis; sand characterization to further the understanding of global sand properties and processes; support of other instrument observations; sample extraction site documentation; range-finding for arm and instrument placement; rover hardware and instrument monitoring and safety; terrain assessment; landscape geomorphology; and support of rover robotic arm commissioning. Operation of the instrument has demonstrated that imaging fully illuminated, dust-free targets yields the best results, with complementary information obtained from shadowed images. The light-emitting diodes (LEDs) allow satisfactory night imaging but do not improve daytime shadowed imaging. MAHLI's combination of fine-scale, science-driven resolution, RGB color, the ability to focus over a large range of distances, and relatively large field of view (FOV), have maximized the return of science and science-enabling observations given the MSL mission architecture and constraints.

  9. Instrumentation and telemetry systems for free-flight drop model testing

    NASA Technical Reports Server (NTRS)

    Hyde, Charles R.; Massie, Jeffrey J.

    1993-01-01

    This paper presents instrumentation and telemetry system techniques used in free-flight research drop model testing at the NASA Langley Research Center. The free-flight drop model test technique is used to conduct flight dynamics research of high performance aircraft using dynamically scaled models. The free-flight drop model flight testing supplements research using computer analysis and wind tunnel testing. The drop models are scaled to approximately 20 percent of the size of the actual aircraft. This paper presents an introduction to the Free-Flight Drop Model Program which is followed by a description of the current instrumentation and telemetry systems used at the NASA Langley Research Center, Plum Tree Test Site. The paper describes three telemetry downlinks used to acquire the data, video, and radar tracking information from the model. Also described are two telemetry uplinks, one used to fly the model employing a ground-based flight control computer and a second to activate commands for visual tracking and parachute recovery of the model. The paper concludes with a discussion of free-flight drop model instrumentation and telemetry system development currently in progress for future drop model projects at the NASA Langley Research Center.

  10. Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of β-agonists in pharmaceutical and pig-feed samples.

    PubMed

    Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Doan, Thi Tuoi; Ta, Thi Thao; Sáiz, Jorge; Nguyen, Thi Quynh Hoa; Hauser, Peter C; Mai, Thanh Duc

    2014-09-19

    An inexpensive, robust and easy to use portable capillary electrophoresis instrument with miniaturized high-voltage capacitively coupled contactless conductivity detection was developed. The system utilizes pneumatic operation to manipulate the solutions for all flushing steps. The different operations, i.e. capillary flushing, interface rinsing, and electrophoretic separation, are easily activated by turning an electronic switch. To allow the analysis of samples with limited available volume, and to render the construction less complicated compared to a computer-controlled counterpart, sample injection is carried out hydrodynamically directly from the sample vial into the capillary by manual syphoning. The system is a well performing solution where the financial means for the highly expensive commercial instruments are not available and where the in-house construction of a sophisticated automated instrument is not possible due to limited mechanical and electronic workshop facilities and software programming expertise. For demonstration, the system was employed successfully for the determination of some β-agonists, namely salbutamol, metoprolol and ractopamine down to 0.7ppm in pharmaceutical and pig-feed sample matrices in Vietnam. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. High Resolution Doppler Imager

    NASA Technical Reports Server (NTRS)

    Hays, Paul B.

    1999-01-01

    This report summarizes the accomplishments of the High Resolution Doppler Imager (HRDI) on UARS spacecraft during the period 4/l/96 - 3/31/99. During this period, HRDI operation, data processing, and data analysis continued, and there was a high level of vitality in the HRDI project. The HRDI has been collecting data from the stratosphere, mesosphere, and lower thermosphere since instrument activation on October 1, 1991. The HRDI team has stressed three areas since operations commenced: 1) operation of the instrument in a manner which maximizes the quality and versatility of the collected data; 2) algorithm development and validation to produce a high-quality data product; and 3) scientific studies, primarily of the dynamics of the middle atmosphere. There has been no significant degradation in the HRDI instrument since operations began nearly 8 years ago. HRDI operations are fairly routine, although we have continued to look for ways to improve the quality of the scientific product, either by improving existing modes, or by designing new ones. The HRDI instrument has been programmed to collect data for new scientific studies, such as measurements of fluorescence from plants, measuring cloud top heights, and lower atmosphere H2O.

  12. Earth observing system. Output data products and input requirements, version 2.0. Volume 1: Instrument data product characteristics

    NASA Technical Reports Server (NTRS)

    Lu, Yun-Chi; Chang, Hyo Duck; Krupp, Brian; Kumar, Ravindra; Swaroop, Anand

    1992-01-01

    Information on Earth Observing System (EOS) output data products and input data requirements that has been compiled by the Science Processing Support Office (SPSO) at GSFC is presented. Since Version 1.0 of the SPSO Report was released in August 1991, there have been significant changes in the EOS program. In anticipation of a likely budget cut for the EOS Project, NASA HQ restructured the EOS program. An initial program consisting of two large platforms was replaced by plans for multiple, smaller platforms, and some EOS instruments were either deselected or descoped. Updated payload information reflecting the restructured EOS program superseding the August 1991 version of the SPSO report is included. This report has been expanded to cover information on non-EOS data products, and consists of three volumes (Volumes 1, 2, and 3). Volume 1 provides information on instrument outputs and input requirements. Volume 2 is devoted to Interdisciplinary Science (IDS) outputs and input requirements, including the 'best' and 'alternative' match analysis. Volume 3 provides information about retrieval algorithms, non-EOS input requirements of instrument teams and IDS investigators, and availability of non-EOS data products at seven primary Distributed Active Archive Centers (DAAC's).

  13. Sample registration software for process automation in the Neutron Activation Analysis (NAA) Facility in Malaysia nuclear agency

    NASA Astrophysics Data System (ADS)

    Rahman, Nur Aira Abd; Yussup, Nolida; Salim, Nazaratul Ashifa Bt. Abdullah; Ibrahim, Maslina Bt. Mohd; Mokhtar, Mukhlis B.; Soh@Shaari, Syirrazie Bin Che; Azman, Azraf B.; Ismail, Nadiah Binti

    2015-04-01

    Neutron Activation Analysis (NAA) had been established in Nuclear Malaysia since 1980s. Most of the procedures established were done manually including sample registration. The samples were recorded manually in a logbook and given ID number. Then all samples, standards, SRM and blank were recorded on the irradiation vial and several forms prior to irradiation. These manual procedures carried out by the NAA laboratory personnel were time consuming and not efficient. Sample registration software is developed as part of IAEA/CRP project on `Development of Process Automation in the Neutron Activation Analysis (NAA) Facility in Malaysia Nuclear Agency (RC17399)'. The objective of the project is to create a pc-based data entry software during sample preparation stage. This is an effective method to replace redundant manual data entries that needs to be completed by laboratory personnel. The software developed will automatically generate sample code for each sample in one batch, create printable registration forms for administration purpose, and store selected parameters that will be passed to sample analysis program. The software is developed by using National Instruments Labview 8.6.

  14. Structural analysis and biological activity of a highly regular glycosaminoglycan from Achatina fulica.

    PubMed

    Liu, Jie; Zhou, Lutan; He, Zhicheng; Gao, Na; Shang, Feineng; Xu, Jianping; Li, Zi; Yang, Zengming; Wu, Mingyi; Zhao, Jinhua

    2018-02-01

    Edible snails have been widely used as a health food and medicine in many countries. A unique glycosaminoglycan (AF-GAG) was purified from Achatina fulica. Its structure was analyzed and characterized by chemical and instrumental methods, such as Fourier transform infrared spectroscopy, analysis of monosaccharide composition, and 1D/2D nuclear magnetic resonance spectroscopy. Chemical composition analysis indicated that AF-GAG is composed of iduronic acid (IdoA) and N-acetyl-glucosamine (GlcNAc) and its average molecular weight is 118kDa. Structural analysis clarified that the uronic acid unit in glycosaminoglycan (GAG) is the fully epimerized and the sequence of AF-GAG is →4)-α-GlcNAc (1→4)-α-IdoA2S (1→. Although its structure with a uniform repeating disaccharide is similar to those of heparin and heparan sulfate, this GAG is structurally highly regular and homogeneous. Anticoagulant activity assays indicated that AF-GAG exhibits no anticoagulant activities, but considering its structural characteristic, other bioactivities such as heparanase inhibition may be worthy of further study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Mass Spectrometry Theatre: A Model for Big-Screen Instrumental Analysis

    ERIC Educational Resources Information Center

    Allison, John

    2008-01-01

    Teaching lecture or lab courses in instrumental analysis can be a source of frustration since one can only crowd a small number of students around a single instrument, typically leading to round-robin approaches. Round-robin labs can spread students into multiple labs and limit instructor-student interactions. We discuss "Mass Spectrometry…

  16. Clinical assessment of the physical activity pattern of chronic fatigue syndrome patients: a validation of three methods.

    PubMed

    Scheeres, Korine; Knoop, Hans; Meer, van der Jos; Bleijenberg, Gijs

    2009-04-01

    Effective treatment of chronic fatigue syndrome (CFS) with cognitive behavioural therapy (CBT) relies on a correct classification of so called 'fluctuating active' versus 'passive' patients. For successful treatment with CBT is it especially important to recognise the passive patients and give them a tailored treatment protocol. In the present study it was evaluated whether CFS patient's physical activity pattern can be assessed most accurately with the 'Activity Pattern Interview' (API), the International Physical Activity Questionnaire (IPAQ) or the CFS-Activity Questionnaire (CFS-AQ). The three instruments were validated compared to actometers. Actometers are until now the best and most objective instrument to measure physical activity, but they are too expensive and time consuming for most clinical practice settings. In total 226 CFS patients enrolled for CBT therapy answered the API at intake and filled in the two questionnaires. Directly after intake they wore the actometer for two weeks. Based on receiver operating characteristic (ROC) curves the validity of the three methods were assessed and compared. Both the API and the two questionnaires had an acceptable validity (0.64 to 0.71). None of the three instruments was significantly better than the others. The proportion of false predictions was rather high for all three instrument. The IPAQ had the highest proportion of correct passive predictions (sensitivity 70.1%). The validity of all three instruments appeared to be fair, and all showed rather high proportions of false classifications. Hence in fact none of the tested instruments could really be called satisfactory. Because the IPAQ showed to be the best in correctly predicting 'passive' CFS patients, which is most essentially related to treatment results, it was concluded that the IPAQ is the preferable alternative for an actometer when treating CFS patients in clinical practice.

  17. Economic instruments for population diet and physical activity behaviour change: a systematic scoping review.

    PubMed

    Shemilt, Ian; Hollands, Gareth J; Marteau, Theresa M; Nakamura, Ryota; Jebb, Susan A; Kelly, Michael P; Suhrcke, Marc; Ogilvie, David

    2013-01-01

    Unhealthy diet and low levels of physical activity are common behavioural factors in the aetiology of many non-communicable diseases. Recent years have witnessed an upsurge of policy and research interest in the use of taxes and other economic instruments to improve population health. To assemble, configure and analyse empirical research studies available to inform the public health case for using economic instruments to promote dietary and physical activity behaviour change. We conducted a systematic scoping review of evidence for the effects of specific interventions to change, or general exposure to variations in, prices or income on dietary and physical activity behaviours and corollary outcomes. Systematic electronic searches and parallel snowball searches retrieved >1 million study records. Text mining technologies were used to prioritise title-abstract records for screening. Eligible studies were selected, classified and analysed in terms of key characteristics and principal findings, using a narrative, configuring synthesis focused on implications for policy and further research. We identified 880 eligible studies, including 192 intervention studies and 768 studies that incorporated evidence for prices or income as correlates or determinants of target outcomes. Current evidence for the effects of economic instruments and exposures on diet and physical activity is limited in quality and equivocal in terms of its policy implications. Direct evidence for the effects of economic instruments is heavily skewed towards impacts on diet, with a relative lack of evidence for impacts on physical activity. The evidence-based case for using economic instruments to promote dietary and physical activity behaviour change may be less compelling than some proponents have claimed. Future research should include measurement of people's actual behavioural responses using study designs capable of generating reliable causal inferences regarding intervention effects. Policy implementation needs to be carefully aligned with evaluation planning and design.

  18. International Space Station Remote Sensing Pointing Analysis

    NASA Technical Reports Server (NTRS)

    Jacobson, Craig A.

    2007-01-01

    This paper analyzes the geometric and disturbance aspects of utilizing the International Space Station for remote sensing of earth targets. The proposed instrument (in prototype development) is SHORE (Station High-Performance Ocean Research Experiment), a multiband optical spectrometer with 15 m pixel resolution. The analysis investigates the contribution of the error effects to the quality of data collected by the instrument. This analysis supported the preliminary studies to determine feasibility of utilizing the International Space Station as an observing platform for a SHORE type of instrument. Rigorous analyses will be performed if a SHORE flight program is initiated. The analysis begins with the discussion of the coordinate systems involved and then conversion from the target coordinate system to the instrument coordinate system. Next the geometry of remote observations from the Space Station is investigated including the effects of the instrument location in Space Station and the effects of the line of sight to the target. The disturbance and error environment on Space Station is discussed covering factors contributing to drift and jitter, accuracy of pointing data and target and instrument accuracies.

  19. The Effects of Reflective Activities on Skill Adaptation in a Work-Related Instrumental Learning Setting

    ERIC Educational Resources Information Center

    Roessger, Kevin M.

    2014-01-01

    In work-related instrumental learning contexts, the role of reflective activities is unclear. Kolb's experiential learning theory and Mezirow's transformative learning theory predict skill adaptation as an outcome. This prediction was tested by manipulating reflective activities and assessing participants' response and error rates during novel…

  20. Investigating the Impact of Formal Reflective Activities on Skill Adaptation in a Work-Related Instrumental Learning Setting

    ERIC Educational Resources Information Center

    Roessger, Kevin M.

    2013-01-01

    In work-related, instrumental learning contexts the role of reflective activities is unclear. Kolb's (1985) experiential learning theory and Mezirow's transformative learning theory (2000) predict skill-adaptation as a possible outcome. This prediction was experimentally explored by manipulating reflective activities and assessing participants'…

Top