Science.gov

Sample records for active geothermal system

  1. Geothermal systems

    NASA Technical Reports Server (NTRS)

    Mohl, C.

    1978-01-01

    Several tasks of JPL related to geothermal energy are discussed. The major task is the procurement and test and evaluation of a helical screw drive (wellhead unit). A general review of geothermal energy systems is given. The presentation focuses attention on geothermal reservoirs in California, with graphs and charts to support the discussion. Included are discussions on cost analysis, systems maintenance, and a comparison of geothermal and conventional heating and cooling systems.

  2. Gold enrichment in active geothermal systems by accumulating colloidal suspensions

    NASA Astrophysics Data System (ADS)

    Hannington, Mark; Harðardóttir, Vigdis; Garbe-Schönberg, Dieter; Brown, Kevin L.

    2016-04-01

    The origins of high-grade hydrothermal ore deposits are debated, but active geothermal systems provide important clues to their formation. The highest concentrations of gold are found in geothermal systems with direct links to island arc magmatism. Yet, similar concentrations have also been found in the absence of any input from arc magmas, for example, in the Reykjanes geothermal field, Iceland. Here we analyse brine samples taken from deep wells at Reykjanes and find that gold concentrations in the reservoir zone have increased over the past seven years from an average of 3 ppb to 14 ppb. The metal concentrations greatly exceed the maximum solubility of gold in the reservoir under saturated conditions and are now nearly two orders of magnitude higher than in mid-ocean ridge black smoker fluids--the direct analogues of Reykjanes deep liquids. We suggest that ongoing extraction of brine, the resulting pressure drop, and increased boiling have caused gold to drop out of solution and become trapped in the reservoir as a colloidal suspension. This process may explain how the stock of metal in the reservoirs of fossil geothermal systems could have increased over time and thus become available for the formation of gold-rich ore deposits.

  3. Calc-silicate mineralization in active geothermal systems

    SciTech Connect

    Bird, D.K.; Schiffman, P.; Elders, W.A.; Williams, A.E.; McDowell, S.D.

    1983-01-01

    The detailed study of calc-silicate mineral zones and coexisting phase relations in the Cerro Prieto geothermal system were used as examples for thermodynamic evaluation of phase relations among minerals of variable composition and to calculate the chemical characteristics of hydrothermal solutions compatible with the observed calc-silicate assemblages. In general there is a close correlation between calculated and observed fluid compositions. Calculated fugacities of O{sub 2} at about 320{degrees}C in the Cerro Prieto geothermal system are about five orders of magnitude less than that at the nearby Salton Sea geothermal system. This observation is consistent with the occurrence of Fe{sup 3+} rich epidotes in the latter system and the presence of prehnite at Cerro Prieto.

  4. Active geothermal systems as natural analogs of HLW repositories

    SciTech Connect

    Elders, W.A.; Williams, A.E.; Cohen, L.H.

    1988-01-01

    Geologic analogs of long-lived processes in high-level waste (HLW) repositories have been much studied in recent years. However, most of these occurrences either involve natural processes going on today at 25{degree}C, or, if they are concerned with behavior at temperatures similar to the peak temperatures anticipated near HLW canisters, have long since ended. This paper points out the usefulness of studying modern geothermal systems as natural analogs, and to illustrate the concept with a dramatic example, the Salton Sea geothermal system (SSGS).

  5. Geothermal materials development activities

    SciTech Connect

    Kukacka, L.E.

    1993-06-01

    This ongoing R&D program is a part of the Core Research Category of the Department of Energy/Geothermal Division initiative to accelerate the utilization of geothermal resources. High risk materials problems that if successfully solved will result in significant reductions in well drilling, fluid transport and energy conversion costs, are emphasized. The project has already developed several advanced materials systems that are being used by the geothermal industry and by Northeastern Electric, Gas and Steam Utilities. Specific topics currently being addressed include lightweight C0{sub 2}-resistant well cements, thermally conductive scale and corrosion resistant liner systems, chemical systems for lost circulation control, elastomer-metal bonding systems, and corrosion mitigation at the Geysers. Efforts to enhance the transfer of the technologies developed in these activities to other sectors of the economy are also underway.

  6. Sensitivity of predicted scaling and permeability in Enhanced Geothermal Systems to Thermodynamic Data and Activity Models

    NASA Astrophysics Data System (ADS)

    Hingerl, Ferdinand F.; Wagner, Thomas; Kulik, Dmitrii A.; Kosakowski, Georg; Driesner, Thomas; Thomsen, Kaj

    2010-05-01

    A consortium of research groups from ETH Zurich, EPF Lausanne, the Paul Scherrer Institut and the University of Bonn collaborates in a comprehensive program of basic research on key aspects of the Enhanced Geothermal Systems (EGSs). As part of this GEOTHERM project (www.geotherm.ethz.ch), we concentrate on the fundamental investigation of thermodynamic models suitable for describing fluid-rock interactions at geothermal conditions. Predictions of the fluid-rock interaction in EGS still face several major challenges. Slight variations in the input thermodynamic and kinetic parameters may result in significant differences in the predicted mineral solubilities and stable assemblage. Realistic modeling of mineral precipitation in turn has implications onto our understanding of the permeability evolution of the geothermal reservoir, as well as the scaling in technical installations. In order to reasonably model an EGS, thermodynamic databases and activity models must be tailored to geothermal conditions. We therefore implemented in GEMS code the Pitzer formalism, which is the standard model used for computing thermodynamic excess properties of brines at elevated temperatures and pressures. This model, however, depends on a vast amount of interaction parameters, which are to a substantial extend unknown. Furthermore, a high order polynomial temperature interpolation makes extrapolation unreliable if not impossible. As an alternative we additionally implemented the EUNIQUAC activity model. EUNIQUAC requires fewer empirical fit parameters (only binary interaction parameters needed) and uses simpler and more stable temperature and pressure extrapolations. This results in an increase in computation speed, which is of crucial importance when performing coupled long term simulations of geothermal reservoirs. To achieve better performance under geothermal conditions, we are currently partly reformulating EUNIQUAC and refitting the existing parameter set. First results of the

  7. Modeling of geothermal systems

    SciTech Connect

    Bodvarsson, G.S.; Pruess, K.; Lippmann, M.J.

    1985-03-01

    During the last decade the use of numerical modeling for geothermal resource evaluation has grown significantly, and new modeling approaches have been developed. In this paper we present a summary of the present status in numerical modeling of geothermal systems, emphasizing recent developments. Different modeling approaches are described and their applicability discussed. The various modeling tasks, including natural-state, exploitation, injection, multi-component and subsidence modeling, are illustrated with geothermal field examples. 99 refs., 14 figs.

  8. Hydrothermal mineralogy and fluid inclusions chemistry to understand the roots of active geothermal systems

    NASA Astrophysics Data System (ADS)

    Chambefort, I. S.; Dilles, J. H.; Heinrich, C.

    2013-12-01

    An integrated study to link magmatic textures, magmatic mineral compositions, hydrothermal alteration zoning, hydrothermal mineral chemistry, and fluid inclusion compositions has been undertaken to link an intrusive complex and its degassing alteration halo with their surface equivalent in an active geothermal system. Ngatamariki geothermal system, New Zealand, presents a unique feature in the Taupo Volcanic Zone (TVZ). Drilling intercepted an intrusive complex with a high temperature alteration halo similarly to what is observed in magmatic-derived ore deposits. Thus it presents the perfect opportunity to study the magmatic-hydrothermal transition of the TVZ by characterizing the nature of the deep magmatic fluids link to the heat source of the world known geothermal fields. The record of magmatic-hydrothermal fluid-rock interactions preserved at Ngatamariki may be analogous of processes presently occurring at depth beneath TVZ geothermal systems. The intrusive complex consists of over 5 km3 of tonalite, diorite, basalt and aplitic dykes. Evidence of undercooling subsolidus magmatic textures such as myrmekite and skeletal overgrowth are commonly observed and often linked to volatile loss. The fluids released during the crystallization of the intrusive complex are interpreted to be at the origin of the surrounding high temperature alteration halo. Advanced argillic to potassic alteration and high temperature acidic assemblage is associated with high-temperature quartz veining at depth and vuggy silica at the paleo-surface. Major element compositions of the white micas associated with the high temperature halo show a transition from, muscovite to phengite, muscovitic illite away from the intrusion, with a transition to pyrophyllite and/ or topaz, and andalusite characteristic of more acidic conditions. Abundant high-density (up to 59 wt% NaCl eq and homogenization temperatures of 550 degree Celsius and above) coexist with low-density vapor fluid inclusions. This

  9. Cordon Caulle: an active volcanic-geothermal extensional system of Southern Andes of Chile

    NASA Astrophysics Data System (ADS)

    Sepulveda, F.

    2013-05-01

    Cordon Caulle (CC; 40.5° S) is an active volcanic-geothermal system of the Southern Volcanic Zone (SVZ; 37°-44°S). Morphologically, the CC system is a 6 km x 13 km volcanic plateau bordered by NW-trending structures, limited by Puyehue Volcano to the SE and by Caldera Nevada Caldera to the NW. While the SVZ is dominantly basaltic, CC is unique in that it has produced a wide compositional spectrum from basalt to rhyolite. The most recent volcanic activity of Puyehue-CC (last 70 ky) is dominantly silicic, including two historic fissure eruptions (1921-1922; 1960) and a recent central eruption from Puyehue Volcano (2011). Abnormally silicic volcanism was formerly attributed to a localized compression and long-term magma residence and differentiation, resulting from the NW orientation of underlying CC structures with respect to a NE-oriented σ1 (linked to regional strike-slip stress state). However, later studies, including examination of morpho-tectonic features; detailed structural analysis of the 1960 eruption (triggered by Mw 9.5 1960 Chilean Earthquake); InSAR deformation and gravity surveys, point to both historic and long-term extension at CC with σhmax oriented NNW to NW. The pre-2011 (i.e. Puyehue Volcano eruption) geothermal features of CC included boiling hot springs and geysers (Caldera Nevada) and fumaroles (CC and Puyehue Volcano). Both water and gas chemistry surveys were undertaken to assess the source fluid composition and equilibrium temperature. The combination of water and gas geothermometers led to a conceptual model of a stratified geothermal reservoir, with shallow, low-chloride, steam-heated aquifers equilibrated at temperatures between 150°-180°C, overlying a deeper, possibly dominated reservoir with temperatures in excess of 280°C. Gas chemistry also produced the highest He ratios of the SVZ, in agreement with a relatively pure, undiluted magmatic signature and heat source fueling the geothermal system. Other indicators such as N2/Ar

  10. Origin and Distribution of Thiophenes and Furans in Gas Discharges from Active Volcanoes and Geothermal Systems

    PubMed Central

    Tassi, Franco; Montegrossi, Giordano; Capecchiacci, Francesco; Vaselli, Orlando

    2010-01-01

    The composition of non-methane organic volatile compounds (VOCs) determined in 139 thermal gas discharges from 18 different geothermal and volcanic systems in Italy and Latin America, consists of C2–C20 species pertaining to the alkanes, alkenes, aromatics and O-, S- and N-bearing classes of compounds. Thiophenes and mono-aromatics, especially the methylated species, are strongly enriched in fluids emissions related to hydrothermal systems. Addition of hydrogen sulphide to dienes and electrophilic methylation involving halogenated radicals may be invoked for the formation of these species. On the contrary, the formation of furans, with the only exception of C4H8O, seems to be favoured at oxidizing conditions and relatively high temperatures, although mechanisms similar to those hypothesized for the production of thiophenes can be suggested. Such thermodynamic features are typical of fluid reservoirs feeding high-temperature thermal discharges of volcanoes characterised by strong degassing activity, which are likely affected by conspicuous contribution from a magmatic source. The composition of heteroaromatics in fluids naturally discharged from active volcanoes and geothermal areas can then be considered largely dependent on the interplay between hydrothermal vs. magmatic contributions. This implies that they can be used as useful geochemical tools to be successfully applied in both volcanic monitoring and geothermal prospection. PMID:20480029

  11. Origin and distribution of thiophenes and furans in gas discharges from active volcanoes and geothermal systems.

    PubMed

    Tassi, Franco; Montegrossi, Giordano; Capecchiacci, Francesco; Vaselli, Orlando

    2010-03-31

    The composition of non-methane organic volatile compounds (VOCs) determined in 139 thermal gas discharges from 18 different geothermal and volcanic systems in Italy and Latin America, consists of C(2)-C(20) species pertaining to the alkanes, alkenes, aromatics and O-, S- and N-bearing classes of compounds. Thiophenes and mono-aromatics, especially the methylated species, are strongly enriched in fluids emissions related to hydrothermal systems. Addition of hydrogen sulphide to dienes and electrophilic methylation involving halogenated radicals may be invoked for the formation of these species. On the contrary, the formation of furans, with the only exception of C(4)H(8)O, seems to be favoured at oxidizing conditions and relatively high temperatures, although mechanisms similar to those hypothesized for the production of thiophenes can be suggested. Such thermodynamic features are typical of fluid reservoirs feeding high-temperature thermal discharges of volcanoes characterised by strong degassing activity, which are likely affected by conspicuous contribution from a magmatic source. The composition of heteroaromatics in fluids naturally discharged from active volcanoes and geothermal areas can then be considered largely dependent on the interplay between hydrothermal vs. magmatic contributions. This implies that they can be used as useful geochemical tools to be successfully applied in both volcanic monitoring and geothermal prospection.

  12. Geotherm: the U.S. geological survey geothermal information system

    USGS Publications Warehouse

    Bliss, J.D.; Rapport, A.

    1983-01-01

    GEOTHERM is a comprehensive system of public databases and software used to store, locate, and evaluate information on the geology, geochemistry, and hydrology of geothermal systems. Three main databases address the general characteristics of geothermal wells and fields, and the chemical properties of geothermal fluids; the last database is currently the most active. System tasks are divided into four areas: (1) data acquisition and entry, involving data entry via word processors and magnetic tape; (2) quality assurance, including the criteria and standards handbook and front-end data-screening programs; (3) operation, involving database backups and information extraction; and (4) user assistance, preparation of such items as application programs, and a quarterly newsletter. The principal task of GEOTHERM is to provide information and research support for the conduct of national geothermal-resource assessments. The principal users of GEOTHERM are those involved with the Geothermal Research Program of the U.S. Geological Survey. Information in the system is available to the public on request. ?? 1983.

  13. Geothermal Systems for School.

    ERIC Educational Resources Information Center

    Dinse, David H.

    1998-01-01

    Describes an award-winning school heating and cooling system in which two energy-efficient technologies, variable-flow pumping and geothermal heat pumps, were combined. The basic system schematic and annual energy use and cost savings statistics are provided. (GR)

  14. Seismic properties of fluid bearing formations in magmatic geothermal systems: can we directly detect geothermal activity with seismic methods?

    NASA Astrophysics Data System (ADS)

    Grab, Melchior; Scott, Samuel; Quintal, Beatriz; Caspari, Eva; Maurer, Hansruedi; Greenhalgh, Stewart

    2016-04-01

    Seismic methods are amongst the most common techniques to explore the earth's subsurface. Seismic properties such as velocities, impedance contrasts and attenuation enable the characterization of the rocks in a geothermal system. The most important goal of geothermal exploration, however, is to describe the enthalpy state of the pore fluids, which act as the main transport medium for the geothermal heat, and to detect permeable structures such as fracture networks, which control the movement of these pore fluids in the subsurface. Since the quantities measured with seismic methods are only indirectly related with the fluid state and the rock permeability, the interpretation of seismic datasets is difficult and usually delivers ambiguous results. To help overcome this problem, we use a numerical modeling tool that quantifies the seismic properties of fractured rock formations that are typically found in magmatic geothermal systems. We incorporate the physics of the pore fluids, ranging from the liquid to the boiling and ultimately vapor state. Furthermore, we consider the hydromechanics of permeable structures at different scales from small cooling joints to large caldera faults as are known to be present in volcanic systems. Our modeling techniques simulate oscillatory compressibility and shear tests and yield the P- and S-wave velocities and attenuation factors of fluid saturated fractured rock volumes. To apply this modeling technique to realistic scenarios, numerous input parameters need to be indentified. The properties of the rock matrix and individual fractures were derived from extensive literature research including a large number of laboratory-based studies. The geometries of fracture networks were provided by structural geologists from their published studies of outcrops. Finally, the physical properties of the pore fluid, ranging from those at ambient pressures and temperatures up to the supercritical conditions, were taken from the fluid physics

  15. Geothermal hot water system

    SciTech Connect

    Dittell, E.W.

    1983-05-10

    Geothermal hot water system including a hot water tank and a warm water tank which are heated independently of each other by a close loop freon system. The closed loop freon system includes a main condenser which heats water for the warm water tank and a super-heated condenser which heats water for the hot water tank, and where the freon passes through a water evaporator which is heated by water such as from a well or other suitable source. The water evaporator in the closed loop freon system passes the water through but no environmental change to the water. An electrical circuit including aquastats in the warm water tank connected therethrough controls operation of the closed loop freon system including respective pumps on the super-heated condenser and main condenser for pumping water. Pumps pump water through the main condenser for the warm tank and through the super-heated condenser for the hot tank. The system provides for energy conservation in that the head pressure of the compressor is kept in the lower operating ranges as determined by the discharge flow of the main condenser which varies by the head pressure and temperature flow control which varies by temperature. The geothermal hot water system uses a least amount of energy in heating the water in the hot tank as well as the warm tank.

  16. National Geothermal Data System (NGDS)

    DOE Data Explorer

    The National Geothermal Data System (NGDS) is a DOE-funded distributed network of databases and data sites. Much of the risk of geothermal energy development is associated with exploring for, confirming and characterizing the available geothermal resources. The overriding purpose of the NGDS is to help mitigate this up-front risk by serving as a central gateway for geothermal and relevant related data as well as a link to distributed data sources. Assessing and categorizing the nation's geothermal resources and consolidating all geothermal data through a publicly accessible data system will support research, stimulate public interest, promote market acceptance and investment, and, in turn, the growth of the geothermal industry. Major participants in the NGDS to date include universities, laboratories, the Arizona Geological Survey and Association of American State Geologists (Arizona Geological Survey, lead), the Geothermal Resources Council, and the U.S. Geological Survey. The Geothermal Energy Association is collaborating with the NGDS to insure that it meets the needs of the geothermal industry.

  17. Federal Interagency Geothermal Activities

    SciTech Connect

    Anderson, Arlene; Prencipe, Loretta; Todaro, Richard M.; Cuyler, David; Eide, Elizabeth

    2011-06-01

    This collaborative document describes the roles and responsibilities of key Federal agencies in the development of geothermal technologies including the U.S. Department of Energy (DOE); the U.S. Department of Agriculture (USDA), including the U.S. Forest Service; the U.S. Department of Interior (DOI), including the United States Geological Survey (USGS) and Bureau of Land Management (BLM); the Environmental Protection Agency (EPA); and the Department of Defense (DOD).

  18. Research drilling in an active geothermal system: Salton Sea Scientific Drilling Project (SSSDP)

    SciTech Connect

    Elders, W.A.

    1987-05-01

    In March 1986 a research borehole, designed to study the processes occurring in an active, high-temperature, magmatically driven hydrothermal system, reached a depth of 3.22 km in the Salton Sea geothermal field at the northern end of the Gulf of California. Only 10% of the borehole was cored; however, an integrated set of drill cuttings, wireline logs, and downhole measurements were obtained using high-temperature tools and cables. Similarly, downhole VSP, gravity, and fluid sampling tools were successfully deployed. The borehole penetrates Pleistocene and upper Pliocene lake and delta sediments with minor extrusive and intrusive igneous rocks, all of which are being progressively altered to greenschist facies hornfelses. A flow test of a zone at 1865 m with a temperature of 305/sup 0/C, produced Na, Ca, and K chloride brines containing 24% of dissolved salts. Flows of up to 200 tons/hr of steam and brine were obtained. An even more productive zone, the deepest tested at 3215 m where the temperature was 355/sup 0/C, briefly attained a peak flow of 400 tons/hr during a 48-hour test. However, this test was marred by interference from other flow zones. Although the borehole was shut in after the 7-in. (17.78-cm) diameter liner parted, a comprehensive program of laboratory studies is underway in about 40 different institutions. Results to date have more than met their original goals. In the summer of 1987, field operations will resume and will include extensive reservoir engineering. However, drilling deeper to penetrate the magmatic rocks that underlie the explored hydrothermal system must await future funding.

  19. geothermal salinity control system

    SciTech Connect

    McCabe, B.C.; Zajac, E.

    1985-01-08

    Highly saline geothermal brine, such as that produced from the lower geothermal reserve of the Salton Sea geothermal field, is diluted with non-geothermal water of much lower salinity in a mixing zone proximate the high temperature end of a geothermal power plant, and preferably down in the production well just above the production zone, so as to reduce the chloride salt content of the production brine to a level that is at or below the saturated level at reinjection temperatures, thereby preventing any material chloride salt scaling at any location in the plant through reinjection. The permanent cemented-in production casing in the well is protected against the corrosive effects of the hot production brine by means of a removable production liner that is generally coextensive with the casing. Said mixing zone is provided in the lower portion of the liner, and the liner establishes an annulus between it and the casing through which said non-geothermal water flows downwardly to the mixing zone so as to exclude the production brine from contact with the casing.

  20. Lassen geothermal system

    SciTech Connect

    Muffler, L.J.P.; Nehring, N.L.; Truesdell, A.H.; Janik, C.J.; Clynne, M.A.; Thompson, J.M.

    1982-01-01

    The Lassen geothermal system consists of a central vapor-dominated reservoir underlain by hot water that discharges peripherally at lower elevations. The major thermal upflow at Bumpass Hell (elevation 2500 m) displays numerour superheated fumaroles, one of which in 1976 was 159/sup 0/C. Gas geothermometers from the fumarole areas and water geothermometers from boiling Cl-bearing waters at Morgan Hot Springs (elevation 1530 m; 8 km south of Bumpass Hell) and from 176/sup 0/C waters in a well 12 km southeast of Bumpass Hell both indicate 230 to 240/sup 0/C for the deep thermal water. With increasing distance from Bumpass Hell, gases are progressively depleted in H/sub 2/S relative to CO/sub 2/ and N/sub 2/, owing to oxidation of H/sub 2/S to pyrite, sulfur, and sulfates and to dilution with atmospheric N/sub 2/. H/sub 2/O/gas ratios and degree of superheat of fumaroles can be explained by mixing of steam of maximum enthalpy (2804 J g/sup -1/) with near-surface water and with the condensate layer overlying the vapor-dominated reservoir.

  1. Geothermal reservoirs in hydrothermal convection systems

    SciTech Connect

    Sorey, M.L.

    1982-01-01

    Geothermal reservoirs commonly exist in hydrothermal convection systems involving fluid circulation downward in areas of recharge and upwards in areas of discharge. Because such reservoirs are not isolated from their surroundings, the nature of thermal and hydrologic connections with the rest of the system may have significant effects on the natural state of the reservoir and on its response to development. Conditions observed at numerous developed and undeveloped geothermal fields are discussed with respect to a basic model of the discharge portion of an active hydrothermal convection system. Effects of reservoir development on surficial discharge of thermal fluid are also delineated.

  2. Investigating Geothermal Activity, Volcanic Systems, and Deep Tectonic Tremor on Akutan Island, Alaska, with Array Seismology

    NASA Astrophysics Data System (ADS)

    Haney, M. M.; Prejean, S. G.; Ghosh, A.; Power, J. A.; Thurber, C. H.

    2012-12-01

    In addition to hosting one of the most active volcanoes in the Aleutian Arc, Akutan Island, Alaska, is the site of a significant geothermal resource within Hot Springs Bay Valley (HSBV). We deployed 15 broadband (30 s to 50 Hz) seismometers in and around HSBV during July 2012 as part of an effort to establish a baseline for background seismic activity in HSBV prior to geothermal production on the island. The stations recorded data on-site and were retrieved in early September 2012. Additional targets for the array include the tracking of deep tectonic tremor known to occur within the Aleutian subduction zone and the characterization of volcano-tectonic (VT) and deep long period (DLP) earthquakes from Akutan Volcano. Because 13 of the stations in the array sit within an area roughly 1.5 km by 1.5 km, we plan to apply methods based on stacking and beamforming to analyze the waveforms of extended signals lacking clear phase arrivals (e.g., tremor). The average spacing of the seismometers, roughly 350 m, provides sensitivity to frequencies between 2-8 Hz. The stacking process also increases the signal-to-noise ratio of small amplitude signals propagating across the array (e.g., naturally occurring geothermal seismicity). As of August 2012, several episodes of tectonic tremor have been detected in the vicinity of Akutan Island during the array deployment based on recordings from nearby permanent stations operated by the Alaska Volcano Observatory (AVO). This is the first small-aperture array deployed in the Aleutian Islands and the results should serve as a guide for future array deployments along the Aleutian Arc as part of the upcoming EarthScope and GeoPRISMS push into Alaska. We demonstrate the power of array methods based on stacking at Akutan Volcano using a sequence of DLP earthquakes from June 11, 2012 that were recorded on the permanent AVO stations. We locate and characterize the lowest frequency portion of the signals at 0.5 Hz. At these low frequencies, the

  3. The role of active and ancient geothermal systems in evolution of Grant Canyon oil field, Railroad Valley, Nye County, Nevada

    SciTech Connect

    Hulen, J.B. ); Bereskin, S.R. ); Bortz, L.C.

    1991-06-01

    Since discovery in 1983, the Grant Canyon field has been among the most prolific oil producers (on a per-well basis) in the US. Production through June 1990 was 12,935,630 bbl of oil, principally from two wells which in tandem have consistently yielded more than 6,000 bbl of oil per day. The field is hosted by highly porous Devonian dolomite breccia loosely cemented with hydrothermal quartz. Results of fluid-inclusion and petrographic research in progress at Grant Canyon suggest that paleogeothermal and perhaps currently circulating geothermal systems may have played a major role in oil-reservoir evolution. For example, as previously reported, the breccia-cementing quartz hosts primary aqueous, aqueous/oil, and oil fluid inclusions which were trapped at about 120C (average homogenization temperature) and document initial oil migration and entrapment as droplets or globules dispersed in dilute (< 2.2 wt.% equivalent NaCl) aqueous solutions. Additional evidence of geothermal connection is that the horst-block trap at Grant Canyon is top and side sealed by valley-fill clastic and volcanic rocks which are locally hydrothermally altered and calcite flooded. These secondary seals are enhanced by disseminated, solid asphaltic residues locally accounting for 23% (volume) of the rock. Current reservoir temperatures at Grant Canyon (120C) and the adjacent Bacon Flat field (171C) attest to vigorous contemporary geothermal activity. Based on results of the authors' Grant Canyon work to date, they suggest that active and paleohydrothermal systems could be viable petroleum exploration targets in otherwise favorable terrain elsewhere in the Basin and Range.

  4. Geothermal systems of the Cascade Range

    USGS Publications Warehouse

    Muffler, L.J.; Bacon, Charles R.; Duffield, W.A.

    1982-01-01

    In the central and southern Cascade Range, plate convergence is oblique, and Quaternary volcanism produces mostly basalt and mafic andesite; large andesite-dacite composite volcanoes and silicic dome fields occur in restricted areas of long-lived igneous activity. To the north, plate convergence is normal, producing widely spaced centers in which mafic lavas are minor. Most Cascade volcanoes are short-lived and unlikely to be underlain at shallow levels by large magma bodies that could support high-temperature geothermal systems. Such systems are known, however, near Meager Mountain, at Newberry Volcano, and near Lassen Peak. Persistent fumaroles occur on several major composite volcanoes, but drilling to date has been insufficient to determine whether exploitable geothermal reservoirs occur at depth. Thermal springs away from the major volcanic centers are few and generally inconspicuous. However, significant geothermal systems along and west of the Cascade Range may well be masked by abundant cold ground water.

  5. Condensation Processes in Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Norman, D. I.; Moore, J. N.

    2005-12-01

    We model condensation processes in geothermal systems to understand how this process changes fluid chemistry. We assume two processes operate in geothermal systems: 1) condensation of a vapor phase derived by boiling an aqueous geothermal fluid into a cool near surface water and 2) condensation of a magmatic vapor by a deep circulating meteoric thermal fluid. It is assumed that the condensation process has two stages. Initially the condensing fluid is under saturated in gaseous species. Condensation of the vapor phase continues until the pressure on the fluid equals the sum of the partial pressures of water and the dissolved gaseous species. At that time bubbles flux through the condensing fluid. In time the fluid and fluxing gas phase come to equilibrium. Calculation shows that during the second stage of the condensation process the liquid phase becomes enriched in more soluble gaseous species like CO2 and H2S, and depleted in less soluble species like CH4 and N2. Stage 2 condensation processes can therefore be monitored by ratios of more and less condensable species like CO2/N2. Condensation of vapor released by boiling geothermal fluids results in liquids with high concentrations of H2S and CO2 like is seen in geothermal system steam-heated waters. Condensation of a magmatic vapor into circulating meteoric water has been proposed, but not well demonstrated. We compare to our models the Cerro Prieto, Mexico gas analysis data set collected over twelve years time by USGS personnel. It was assumed for modeling that the Cerro Prieto geothermal fluids are circulating meteoritic fluids with N2/Ar ratios about 40 to which is added a magmatic vapor with N2/Ar ratio = 400. The Cerro Prieto analyses show a strong correlation between N2/Ar and CO2/N2 as predicted by calculation. Two dimensional image plots of well N2/Ar + CO2/N2 show a bull's-eye pattern on the geothermal field. Image plots of analyses collected over a year or less time show N2/Ar and CO2/N2 hot spots

  6. An Evaluation of Enhanced Geothermal Systems Technology

    SciTech Connect

    Jelacic, Allan; Fortuna, Raymond; LaSala, Raymond; Nathwani, Jay; Nix, Gerald; Visser, Charles; Green, Bruce; Renner, Joel; Blankenship, Douglas; Kennedy, Mack; Bruton, Carol

    2008-04-01

    This 2008 document presents the results of an eight-month study by the Department of Energy (DOE) and its support staff at the national laboratories concerning the technological requirements to commercialize a new geothermal technology, Enhanced Geothermal Systems (EGS).

  7. Boise geothermal district heating system

    SciTech Connect

    Hanson, P.J.

    1985-10-01

    This document describes the Boise geothermal district heating project from preliminary feasibility studies completed in 1979 to a fully operational system by 1983. The report includes information about the two local governments that participated in the project - the City of Boise, Idaho and the Boise Warm Springs Water District. It also discusses the federal funding sources; the financial studies; the feasibility studies conducted; the general system planning and design; design of detailed system components; the legal issues involved in production; geological analysis of the resource area; distribution and disposal; the program to market system services; and the methods of retrofitting buildings to use geothermal hot water for space heating. Technically this report describes the Boise City district heating system based on 170/sup 0/F water, a 4000 gpm production system, a 41,000 foot pipeline system, and system economies. Comparable data are also provided for the Boise Warm Springs Water District. 62 figs., 31 tabs.

  8. What is an Enhanced Geothermal System (EGS)? Fact Sheet

    SciTech Connect

    U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy

    2012-09-14

    This Geothermal Technologies Office fact sheet explains how engineered geothermal reservoirs called Enhanced Geothermal Systems are used to produce energy from geothermal resources that are otherwise not economical due to a lack of fluid and/or permeability.

  9. Tiber delta CO2-CH4 degassing: A possible hybrid, tectonically active Sediment-Hosted Geothermal System near Rome

    NASA Astrophysics Data System (ADS)

    Ciotoli, G.; Etiope, G.; Marra, F.; Florindo, F.; Giraudi, C.; Ruggiero, L.

    2016-01-01

    Fiumicino town in the Tiber River delta, near Rome International Airport (Italy), is historically affected by large amounts of carbon dioxide (CO2) in the ground and gas eruptions triggered by shallow drilling. While it is known that CO2 originates from carbonate thermometamorphism and/or mantle degassing, the origin of methane (CH4) associated with CO2 is uncertain and the outgassing spatial distribution is unknown. Combining isotope gas geochemistry, soil gas, and structural-stratigraphic analyses, we provide evidence for a hybrid fluid source system, classifiable as Sediment-Hosted Geothermal System (SHGS), where biotic CH4 from sedimentary rocks is carried by deep geothermic CO2 through active segments of a half-graben. Molecular and isotopic composition of CH4 and concentration of heavier alkanes (ethane and propane), obtained from gas vents and soil gas throughout the delta area, reveal that thermogenic CH4 (up to 3.7 vol% in soil gas; δ13CCH4: -37 to -40‰ VPDB-Vienna Peedee Belemnite, and δ2HCH4: -162 to -203‰ VSMOW - Vienna Standard Mean Ocean Water in gas vents) prevails over possible microbial and abiotic components. The hydrocarbons likely result from known Meso-Cenozoic petroleum systems of the Latium Tyrrhenian coast. Overmaturation of source rocks or molecular fractionation induced by gas migration are likely responsible for increased C1/C2+ ratios. CO2 and CH4 soil gas anomalies are scattered along NW-SE and W-E alignments, which, based on borehole, geomorphologic, and structural-stratigraphic analyses, coincide with active faults of a half-graben that seems to have controlled the recent evolution of the Tiber delta. This SHGS can be a source of considerable greenhouse gas emissions to the atmosphere and hazards for humans and buildings.

  10. Enhanced Geothermal Systems

    SciTech Connect

    Jeanloz, R.; Stone, H.

    2013-12-31

    DOE, through the Geothermal Technologies Office (GTO) within the Office of Energy Efficiency and Renewable Energy, requested this study, identifying a focus on: i) assessment of technologies and approaches for subsurface imaging and characterization so as to be able to validate EGS opportunities, and ii) assessment of approaches toward creating sites for EGS, including science and engineering to enhance permeability and increase the recovery factor. Two days of briefings provided in-depth discussion of a wide range of themes and challenges in EGS, and represented perspectives from industry, government laboratories and university researchers. JASON also contacted colleagues from universities, government labs and industry in further conversations to learn the state of the field and potential technologies relevant to EGS.

  11. Geothermal Data from the National Geothermal Data System (NGDS)

    DOE Data Explorer

    The National Geothermal Data System (NGDS) is a distributed data system providing access to information resources related to geothermal energy from a network of data providers. Data are contributed by academic researchers, private industry, and state and federal agencies. Built on a scalable and open platform through the U.S. Geoscience Information Network (USGIN), NGDS respects data provenance while promoting shared resources.Since NGDS is built using a set of open protocols and standards, relying on the Open Geospatial Consortium (OGC) and International Organization for Standardization (ISO), members of the community may access the data in a variety of proprietary and open-source applications and software. In addition, developers can add functionality to the system by creating new applications based on the open protocols and standards of the NGDS. The NGDS, supported by the U.S. Department of Energy’s Geothermal Technology Program, is intended to provide access to all types of geothermal data to enable geothermal analysis and widespread public use in an effort to reduce the risk of geothermal energy development [copied from http://www.geothermaldata.org/page/about]. See the long list of data contributors at http://geothermaldata.org/page/data-types-and-contributors#data-contributors.

  12. NATIONAL GEOTHERMAL DATA SYSTEM (NGDS) GEOTHERMAL DATA DOMAIN: ASSESSMENT OF GEOTHERMAL COMMUNITY DATA NEEDS

    SciTech Connect

    Anderson, Arlene; Blackwell, David; Chickering, Cathy; Boyd, Toni; Horne, Roland; MacKenzie, Matthew; Moore, Joseph; Nickull, Duane; Richard, Stephen; Shevenell, Lisa A.

    2013-01-01

    To satisfy the critical need for geothermal data to ad- vance geothermal energy as a viable renewable ener- gy contender, the U.S. Department of Energy is in- vesting in the development of the National Geother- mal Data System (NGDS). This paper outlines efforts among geothermal data providers nationwide to sup- ply cutting edge geo-informatics. NGDS geothermal data acquisition, delivery, and methodology are dis- cussed. In particular, this paper addresses the various types of data required to effectively assess geother- mal energy potential and why simple links to existing data are insufficient. To create a platform for ready access by all geothermal stakeholders, the NGDS in- cludes a work plan that addresses data assets and re- sources of interest to users, a survey of data provid- ers, data content models, and how data will be ex- changed and promoted, as well as lessons learned within the geothermal community.

  13. Geothermal systems of northern Nevada

    USGS Publications Warehouse

    Hose, Richard Kenneth; Taylor, Bruce Edward

    1974-01-01

    Hot springs are numerous and nearly uniformly distributed in northern Nevada. Most occur on the flanks of basins, along Basin and Range (late Miocene to Holocene) faults, while some occur in the inner parts of the basins. Surface temperatures of the springs range from slightly above ambient to, boiling; some springs are superheated. Maximum subsurface water temperatures calculated on the basis of quartz solubility range as high as 252?C, although most are below 190?C. Flows range from a trickle to several hundred liters per minute. The Nevada geothermal systems differ markedly from the power-producing system at The Geysers, Calif., and from those areas with a high potential, for power production (e.g., Yellowstone Park, Wyo.; Jemez Mountains, N. Mex.). These other systems are associated with Quaternary felsic volcanic rocks and probably derive their heat from cooling magma rather high in the crust. In northern Nevada, however, felsic volcanic rocks are virtually all older than 10 million years, and. analogous magmatic heat sources are, therefore, probably lacking. Nevada is part of an area of much higher average heat flow than the rest of the United States. In north-central Nevada, geothermal gradients are as great as 64?C per kilometer in bedrock and even higher in basin fill. The high gradients probably result from a combination of thin crust and high temperature upper mantle. We suggest that the geothermal systems of northern Nevada result from circulation of meteoric waters along Basin and Range faults and that their temperature chiefly depends upon (1) depth of circulation and (2) the geothermal gradient near the faults.

  14. Enhanced Geothermal Systems (EGS) R&D Program, Status Report: Foreign Research on Enhanced Geothermal Systems

    SciTech Connect

    McLarty, Lynn; Entingh, Daniel

    2000-09-29

    This report reviews enhanced geothermal systems (EGS) research outside the United States. The term ''enhanced geothermal systems'' refers to the use of advanced technology to extract heat energy from underground in areas with higher than average heat flow but where the natural permeability or fluid content is limited. EGS covers the spectrum of geothermal resources from low permeability hydrothermal to hot dry rock.

  15. Monitoring Biological Activity at Geothermal Power Plants

    SciTech Connect

    Peter Pryfogle

    2005-09-01

    The economic impact of microbial growth in geothermal power plants has been estimated to be as high as $500,000 annually for a 100 MWe plant. Many methods are available to monitor biological activity at these facilities; however, very few plants have any on-line monitoring program in place. Metal coupon, selective culturing (MPN), total organic carbon (TOC), adenosine triphosphate (ATP), respirometry, phospholipid fatty acid (PLFA), and denaturing gradient gel electrophoresis (DGGE) characterizations have been conducted using water samples collected from geothermal plants located in California and Utah. In addition, the on-line performance of a commercial electrochemical monitor, the BIoGEORGE?, has been evaluated during extended deployments at geothermal facilities. This report provides a review of these techniques, presents data on their application from laboratory and field studies, and discusses their value in characterizing and monitoring biological activities at geothermal power plants.

  16. Active metasomatism in the Cerro Prieto geothermal system, Baja California, Mexico: A telescoped low-pressure, low-temperature metamorphic facies series

    NASA Astrophysics Data System (ADS)

    Schiffman, P.; Elders, W. A.; Williams, A. E.; McDowell, S. D.; Bird, D. K.

    1984-01-01

    In the Cerro Prieto geothermal field, carbonate-cemented, quartzofeldspathic sediments of the Colorado River delta are being actively metasomatized into calc-silicate metamorphic rocks by reaction with alkali chloride brines between 200 and 370 °C, at low fluid and lithostatic pressures and low oxygen fugacities. Our petrologic investigations of drill cores and cuttings from more than 50 wells in this field identified a prograde series of zones that include as index minerals wairakite, epidote, prehnite, and clinopyroxene. Associated divariant mineral assemblages are indicative of a very low pressure, low-temperature metamorphic facies series spanning the clay-carbonate, zeolite, greenschist, and amphibolite facies. This hydro-thermal facies series, which is now recognized in other active geothermal systems, is characterized by temperature-telescoped dehydration and decarbonation. Its equivalent can now be sought in fossil hydrothermal systems.

  17. Geothermal activity helps life survive glacial cycles.

    PubMed

    Fraser, Ceridwen I; Terauds, Aleks; Smellie, John; Convey, Peter; Chown, Steven L

    2014-04-15

    Climate change has played a critical role in the evolution and structure of Earth's biodiversity. Geothermal activity, which can maintain ice-free terrain in glaciated regions, provides a tantalizing solution to the question of how diverse life can survive glaciations. No comprehensive assessment of this "geothermal glacial refugia" hypothesis has yet been undertaken, but Antarctica provides a unique setting for doing so. The continent has experienced repeated glaciations that most models indicate blanketed the continent in ice, yet many Antarctic species appear to have evolved in almost total isolation for millions of years, and hence must have persisted in situ throughout. How could terrestrial species have survived extreme glaciation events on the continent? Under a hypothesis of geothermal glacial refugia and subsequent recolonization of nongeothermal regions, we would expect to find greater contemporary diversity close to geothermal sites than in nongeothermal regions, and significant nestedness by distance of this diversity. We used spatial modeling approaches and the most comprehensive, validated terrestrial biodiversity dataset yet created for Antarctica to assess spatial patterns of diversity on the continent. Models clearly support our hypothesis, indicating that geothermally active regions have played a key role in structuring biodiversity patterns in Antarctica. These results provide critical insights into the evolutionary importance of geothermal refugia and the history of Antarctic species.

  18. Geothermal activity helps life survive glacial cycles

    PubMed Central

    Fraser, Ceridwen I.; Terauds, Aleks; Smellie, John; Convey, Peter; Chown, Steven L.

    2014-01-01

    Climate change has played a critical role in the evolution and structure of Earth’s biodiversity. Geothermal activity, which can maintain ice-free terrain in glaciated regions, provides a tantalizing solution to the question of how diverse life can survive glaciations. No comprehensive assessment of this “geothermal glacial refugia” hypothesis has yet been undertaken, but Antarctica provides a unique setting for doing so. The continent has experienced repeated glaciations that most models indicate blanketed the continent in ice, yet many Antarctic species appear to have evolved in almost total isolation for millions of years, and hence must have persisted in situ throughout. How could terrestrial species have survived extreme glaciation events on the continent? Under a hypothesis of geothermal glacial refugia and subsequent recolonization of nongeothermal regions, we would expect to find greater contemporary diversity close to geothermal sites than in nongeothermal regions, and significant nestedness by distance of this diversity. We used spatial modeling approaches and the most comprehensive, validated terrestrial biodiversity dataset yet created for Antarctica to assess spatial patterns of diversity on the continent. Models clearly support our hypothesis, indicating that geothermally active regions have played a key role in structuring biodiversity patterns in Antarctica. These results provide critical insights into the evolutionary importance of geothermal refugia and the history of Antarctic species. PMID:24616489

  19. Geothermal activity helps life survive glacial cycles.

    PubMed

    Fraser, Ceridwen I; Terauds, Aleks; Smellie, John; Convey, Peter; Chown, Steven L

    2014-04-15

    Climate change has played a critical role in the evolution and structure of Earth's biodiversity. Geothermal activity, which can maintain ice-free terrain in glaciated regions, provides a tantalizing solution to the question of how diverse life can survive glaciations. No comprehensive assessment of this "geothermal glacial refugia" hypothesis has yet been undertaken, but Antarctica provides a unique setting for doing so. The continent has experienced repeated glaciations that most models indicate blanketed the continent in ice, yet many Antarctic species appear to have evolved in almost total isolation for millions of years, and hence must have persisted in situ throughout. How could terrestrial species have survived extreme glaciation events on the continent? Under a hypothesis of geothermal glacial refugia and subsequent recolonization of nongeothermal regions, we would expect to find greater contemporary diversity close to geothermal sites than in nongeothermal regions, and significant nestedness by distance of this diversity. We used spatial modeling approaches and the most comprehensive, validated terrestrial biodiversity dataset yet created for Antarctica to assess spatial patterns of diversity on the continent. Models clearly support our hypothesis, indicating that geothermally active regions have played a key role in structuring biodiversity patterns in Antarctica. These results provide critical insights into the evolutionary importance of geothermal refugia and the history of Antarctic species. PMID:24616489

  20. Towards understanding the puzzling lack of acid geothermal springs in Tibet (China): Insight from a comparison with Yellowstone (USA) and some active volcanic hydrothermal systems

    NASA Astrophysics Data System (ADS)

    Guo, Qinghai; Kirk Nordstrom, D.; Blaine McCleskey, R.

    2014-11-01

    Explanations for the lack of acid geothermal springs in Tibet are inferred from a comprehensive hydrochemical comparison of Tibetan geothermal waters with those discharged from Yellowstone (USA) and two active volcanic areas, Nevado del Ruiz (Colombia) and Miravalles (Costa Rica) where acid springs are widely distributed and diversified in terms of geochemical characteristic and origin. For the hydrothermal areas investigated in this study, there appears to be a relationship between the depths of magma chambers and the occurrence of acid, chloride-rich springs formed via direct magmatic fluid absorption. Nevado del Ruiz and Miravalles with magma at or very close to the surface (less than 1-2 km) exhibit very acidic waters containing HCl and H2SO4. In contrast, the Tibetan hydrothermal systems, represented by Yangbajain, usually have fairly deep-seated magma chambers so that the released acid fluids are much more likely to be fully neutralized during transport to the surface. The absence of steam-heated acid waters in Tibet, however, may be primarily due to the lack of a confining layer (like young impermeable lavas at Yellowstone) to separate geothermal steam from underlying neutral chloride waters and the possible scenario that the deep geothermal fluids below Tibet carry less H2S than those below Yellowstone.

  1. Geopressured-geothermal well activities in Louisiana

    SciTech Connect

    John, C.J.

    1992-10-01

    Since September 1978, microseismic networks have operated continuously around US Department of Energy (DOE) geopressured-geothermal well sites to monitor any microearthquake activity in the well vicinity. Microseismic monitoring is necessary before flow testing at a well site to establish the level of local background seismicity. Once flow testing has begun, well development may affect ground elevations and/or may activate growth faults, which are characteristic of the coastal region of southern Louisiana and southeastern Texas where these geopressured-geothermal wells are located. The microseismic networks are designed to detest small-scale local earthquakes indicative of such fault activation. Even after flow testing has ceased, monitoring continues to assess any microearthquake activity delayed by the time dependence of stress migration within the earth. Current monitoring shows no microseismicity in the geopressured-geothermal prospect areas before, during, or after flow testing.

  2. The Socorro Geothermal System: A Low Temperature Geothermal Resource

    NASA Astrophysics Data System (ADS)

    Person, M. A.; Owens, L. B.

    2009-12-01

    The State of New Mexico is endowed with relatively high background heat flow and permeable, fractured crystalline and sedimentary rocks. This combination has given rise to numerous low temperature geothermal systems throughout the state. In many instances, hot springs associated with these systems are located within gaps in regional confining units (a.k.a. hydrologic windows) caused either by fault block rotation or the emplacement of volcanic dikes. The Socorro Geothermal Area (SGA) is a prime example of this type of a forced convection geothermal system. The Socorro geothermal area (SGA) lies 2 miles to the west of the NM Tech Campus near the base of the Socorro Mountain Block and will be assessed for production by drilling a 1500ft test well in September 2009. Published shallow temperature gradient measurements in fractured, permeable (3000 Darcy) granites indicate peak heat flow values as high as 490 mW/m^2 but decreases to 25 mW/m^2 about 10 km to the west within the La Jencia Basin near the foothills of the Magdalena Mountains. Silica and Cation based geothermometers suggest that deep geothermal reservoir reaches temperatures of 80 to 112 deg. C. Carbon14 age dating of shallow groundwater within the discharge area are about 20,000 years old. Hydrothermal models we constructed indicates that Mountain front recharge penetrates to depths of 4.5 km below the La Jencia Basin sedimentary pile into fractured, crystalline rocks. Discharge occurs through a hydrologic window to the east within a breached playa deposit at the western edge of the Socorro Basin. The hydrologic window was caused by fault block rotation. Warm springs which produce several hundred gpm of 32 deg. C water at the surface several miles to the south of the proposed drilling area also attest to the presence of a significant hydrothermal system. This low temperature resource could potentially heat the Campus of NM Tech.

  3. Philip, South Dakota geothermal district heating systems

    SciTech Connect

    Lund, J.W.

    1997-12-01

    The geothermal heating project in Philip, South Dakota which uses the waste water from the Haakon School has now been in operation for 15 years. This project was one of the 23 cost shared by the U.S. DOE starting in 1978, of which 15 became operational. This article describes the geothermal heating system for eight buildings in downtown Philip.

  4. Geothermal reservoir characterization through active thermal testing

    NASA Astrophysics Data System (ADS)

    Jung, Martin; Klepikova, Maria; Jalali, Mohammadreza; Fisch, Hansruedi; Loew, Simon; Amann, Florian

    2016-04-01

    Development and deployment of Enhanced Geothermal Systems (EGS) as renewable energy resources are part of the Swiss Energy Strategy 2050. To pioneer further EGS projects in Switzerland, a decameter-scale in-situ hydraulic stimulation and circulation (ISC) experiment has been launched at the Grimsel Test Site (GTS). The experiments are hosted in a low fracture density volume of the Grimsel granodiorite, similar to those expected at the potential enhanced geothermal system sites in the deep basement rocks of Northern Switzerland. One of the key goals of this multi-disciplinary experiment is to provide a pre- and post-stimulation characterization of the hydraulic and thermal properties of the stimulated fracture network with high resolution and to determine natural structures controlling the fluid flow and heat transport. Active thermal tests including thermal dilution tests and heat tracer tests allow for investigation of groundwater fluid flow and heat transport. Moreover, the spatial and temporal integrity of distributed temperature sensing (DTS) monitoring upgrades the potential and applicability of thermal tests in boreholes (e.g. Read et al., 2013). Here, we present active thermal test results and discuss the advantages and limitations of this method compared to classical approaches (hydraulic packer tests, solute tracer tests, flowing fluid electrical conductivity logging). The experimental tests were conducted in two boreholes intersected by a few low to moderately transmissive fault zones (fracture transmissivity of about 1E-9 m2/s - 1E-7 m2/s). Our preliminary results show that even in low-permeable environments active thermal testing may provide valuable insights into groundwater and heat transport pathways. Read T., O. Bour, V. Bense, T. Le Borgne, P. Goderniaux, M.V. Klepikova, R. Hochreutener, N. Lavenant, and V. Boschero (2013), Characterizing groundwater flow and heat transport in fractured rock using Fiber-Optic Distributed Temperature Sensing

  5. Neutron imaging for geothermal energy systems

    SciTech Connect

    Bingham, Philip R; Anovitz, Lawrence {Larry} M; Polsky, Yarom

    2013-01-01

    Geothermal systems extract heat energy from the interior of the earth using a working fluid, typically water. Three components are required for a commercially viable geothermal system: heat, fluid, and permeability. Current commercial electricity production using geothermal energy occurs where the three main components exist naturally. These are called hydrothermal systems. In the US, there is an estimated 30 GW of base load electrical power potential for hydrothermal sites. Next generation geothermal systems, named Enhanced Geothermal Systems (EGS), have an estimated potential of 4500 GW. EGSs lack in-situ fluid, permeability or both. As such, the heat exchange system must be developed or engineered within the rock. The envisioned method for producing permeability in the EGS reservoir is hydraulic fracturing, which is rarely practiced in the geothermal industry, and not well understood for the rocks typically present in geothermal reservoirs. High costs associated with trial and error learning in the field have led to an effort to characterize fluid flow and fracturing mechanisms in the laboratory to better understand how to design and manage EGS reservoirs. Neutron radiography has been investigated for potential use in this characterization. An environmental chamber has been developed that is suitable for reproduction of EGS pressures and temperatures and has been tested for both flow and precipitations studies with success for air/liquid interface imaging and 3D reconstruction of precipitation within the core.

  6. Enhanced Geothermal Systems (EGS) R&D Program: US Geothermal Resources Review and Needs Assessment

    SciTech Connect

    Entingh, Dan; McLarty, Lynn

    2000-11-30

    The purpose of this report is to lay the groundwork for an emerging process to assess U.S. geothermal resources that might be suitable for development as Enhanced Geothermal Systems (EGS). Interviews of leading geothermists indicate that doing that will be intertwined with updating assessments of U.S. higher-quality hydrothermal resources and reviewing methods for discovering ''hidden'' hydrothermal and EGS resources. The report reviews the history and status of assessment of high-temperature geothermal resources in the United States. Hydrothermal, Enhanced, and Hot Dry Rock resources are addressed. Geopressured geothermal resources are not. There are three main uses of geothermal resource assessments: (1) They inform industry and other interest parties of reasonable estimates of the amounts and likely locations of known and prospective geothermal resources. This provides a basis for private-sector decisions whether or not to enter the geothermal energy business at all, and for where to look for useful resources. (2) They inform government agencies (Federal, State, local) of the same kinds of information. This can inform strategic decisions, such as whether to continue to invest in creating and stimulating a geothermal industry--e.g., through research or financial incentives. And it informs certain agencies, e.g., Department of Interior, about what kinds of tactical operations might be required to support such activities as exploration and leasing. (3) They help the experts who are performing the assessment(s) to clarify their procedures and data, and in turn, provide the other two kinds of users with a more accurate interpretation of what the resulting estimates mean. The process of conducting this assessment brings a spotlight to bear on what has been accomplished in the domain of detecting and understanding reservoirs, in the period since the last major assessment was conducted.

  7. Small geothermal electric systems for remote powering

    SciTech Connect

    Entingh, Daniel J.; Easwaran, Eyob.; McLarty, Lynn

    1994-08-08

    This report describes conditions and costs at which quite small (100 to 1,000 kilowatt) geothermal systems could be used for off-grid powering at remote locations. This is a first step in a larger process of determining locations and conditions at which markets for such systems could be developed. The results suggest that small geothermal systems offer substantial economic and environmental advantages for powering off-grid towns and villages. Geothermal power is most likely to be economic if the system size is 300 kW or greater, down to reservoir temperatures of 100{degree}C. For system sizes smaller than 300 kW, the economics can be favorable if the reservoir temperature is about 120{degree}C or above. Important markets include sites remote from grids in many developing and developed countries. Estimates of geothermal resources in many developing countries are shown.

  8. Sperry Low Temperature Geothermal Conversion System, Phase I and Phase II. Volume IV. Field activities. Final report

    SciTech Connect

    Harvey, C.

    1984-01-01

    This volume describes those activities which took place at the Sperry DOE Gravity Head plant site at the East Mesa Geothermal Reservoir near Holtville, California between February 1980, when site preparation was begun, and November 1982, when production well 87-6 was permanently abandoned. Construction activities were terminated in July 1981 following the liner collapse in well 87-6. Large amounts of program time manpower, materials, and funds had been diverted in a nine-month struggle to salvage the production well. Once these efforts proved futile, there was no rationale for continuing with the site work unless and until sufficient funding to duplicate well 87-6 was obtained. Activities reported here include: plant construction and pre-operational calibration and testing, drilling and completion of well 87-6, final repair effort on well 87-6, abandonment of well 87-6, and performance evaluation of well 87.6. (MHR)

  9. Radionuclide mobility in the shallow portion of an active high-temperature geothermal system

    SciTech Connect

    Sturchio, N.C.; Seitz, M.G.

    1984-01-01

    Accurate knowledge of the behavior of radionuclides in natural rock-water systems is crucial for the prediction of the consequences of failure of a high-level nuclear waste repository. Work in progress at Argonne National Laboratory involves the detailed geochemical analysis of rock, mineral, and water samples from shallow drill holes in a thermal area of Yellowstone National Park. This study is designed to provide data that will increase our understanding of the behavior of a group of radionuclides in an environment similar to that of the near field of a high-level nuclear waste repository.

  10. Water Resource Assessment of Geothermal Resources and Water Use in Geopressured Geothermal Systems

    SciTech Connect

    Clark, C. E.; Harto, C. B.; Troppe, W. A.

    2011-09-01

    This technical report from Argonne National Laboratory presents an assessment of fresh water demand for future growth in utility-scale geothermal power generation and an analysis of fresh water use in low-temperature geopressured geothermal power generation systems.

  11. Evaluation of geothermal cooling systems for Arizona

    SciTech Connect

    White, D.H.; Goldstone, L.A.

    1982-08-01

    Arizona consumes nearly 50 percent more electricity during the peak summer season of May through part of October, due to the high cooling load met by electrical-driven air conditioning units. This study evaluates two geothermal-driven cooling systems that consume less electricity, namely, absorption cooling and heat pumps. Adsorption cooling requires a geothermal resource above 105{sup 0}C (220{sup 0}F) in order to operate at a reasonable efficiency and capacity. Geothermal resources at these temperatures or above are believed existing in the Phoenix and Tucson areas, but at such depths that geothermal-driven absorption systems have high capital investments. Such capital investments are uneconomical when paid out over only five months of operation each year, but become economical when cascaded with other geothermal uses. There may be other regions of the state, where geothermal resources exist at 105{sup 0}C (220{sup 0}F) or higher at much less depth, such as the Casa Grande/Coolidge or Hyder areas, which might be attractive locations for future plants of the high-technology industries. Geothermal assisted heat pumps have been shown in this study to be economical for nearly all areas of Arizona. They are more economical and reliable than air-to-air heat pumps. Such systems in Arizona depend upon a low-temperature geothermal resource in the narrow range of 15.5 to 26.6{sup 0}C (60 to 80{sup 0}F), and are widely available in Arizona. The state has over 3000 known (existing) thermal wells, out of a total of about 30,000 irrigation wells.

  12. Town of Pagosa Springs geothermal heating system

    SciTech Connect

    Garcia, M.B.

    1997-08-01

    The Town of Pagosa Springs has owned and operated a geothermal heating system since December 1982 to provide geothermal heating during the fall, winter and spring to customers in this small mountain town. Pagosa Springs is located in Archuleta County, Colorado in the southwestern corner of the State. The Town, nestled in majestic mountains, including the Continental Divide to the north and east, has an elevation of 7,150 feet. The use of geothermal water in the immediate area, however, dates back to the 1800`s, with the use of Ute Bands and the Navajo Nation and later by the U.S. Calvery in the 1880`s (Lieutenant McCauley, 1878). The Pagosa area geothermal water has been reported to have healing and therapeutic qualities.

  13. Geothermal heat pump system assisted by geothermal hot spring

    NASA Astrophysics Data System (ADS)

    Nakagawa, M.; Koizumi, Y.

    2016-01-01

    The authors propose a hybrid geothermal heat pump system that could cool buildings in summer and melt snow on the pedestrian sidewalks in winter, utilizing cold mine water and hot spring water. In the proposed system, mine water would be used as cold thermal energy storage, and the heat from the hot spring after its commercial use would be used to melt snow for a certain section of sidewalks. Neither of these sources is viable for direct use application of geothermal resources, however, they become contributing energy factors without producing any greenhouse gases. To assess the feasibility of the proposed system, a series of temperature measurements in the Edgar Mine (Colorado School of Mines' experimental mine) in Idaho Springs, Colorado, were first conducted, and heat/mass transfer analyses of geothermal hot spring water was carried out. The result of the temperature measurements proved that the temperature of Edgar Mine would be low enough to store cold groundwater for use in summer. The heat loss of the hot spring water during its transportation was also calculated, and the heat requirement for snow melt was compared with the heat available from the hot spring water. It was concluded that the heat supply in the proposed usage of hot spring water was insufficient to melt the snow for the entire area that was initially proposed. This feasibility study should serve as an example of "local consumption of locally available energy". If communities start harnessing economically viable local energy in a responsible manner, there will be a foundation upon which to build a sustainable community.

  14. The Geothermal Field Camp: Capacity building for geothermal energy systems in Indonesia

    NASA Astrophysics Data System (ADS)

    Moeck, I.; Sule, R.; Saptadji, N. M.; Deon, F.; Herdianita, N. R.; Jolie, E.; Suryantini, N.; Erbas, K.

    2012-04-01

    In July 2011, the first geothermal field camp was hold on Java/Indonesia near the city Bandung south of the volcanic field Tangkuban Perahu. The course was organized by the Institut Teknologie Bandung (ITB) and International Centre for Geothermal Research (ICGR) of the German Centre of Geosciences (GFZ). The purpose of the Geothermal Field Camp is to combine both field based work and laboratory analysis to ultimately better understand the data collected in field and to integrate data gained by various disciplines. The training belongs to a capacity building program for geothermal energy systems in Indonesia and initially aims to train the trainers. In a later stage, the educational personal trained by the Geothermal Field Camp shall be able to hold their individual Geothermal Field Camp. This is of special interest for Indonesia where the multitude of islands hindered a broad uniform education in geothermal energy systems. However, Indonesia hold the largest geothermal potential worldwide and educated personal is necessary to successfully develop this huge potential scattered over region in future. The interdisciplinary and integrative approach combined with field based and laboratory methodologies is the guiding principle of the Geothermal Field Camp. Tangkuban Perahu was selected because this field allows the integration of field based structural geological analysis, observation and sampling of geothermal manifestations as hot springs and sinters and ultimately of structural geology and surface geochemistry. This innovative training introduces in methods used in exploration geology to study both, fault and fracture systems and fluid chemistry to better understand the selective fluid flow along certain fractures and faults. Field geology covered the systematic measurement of faults and fractures, fault plane and fracture population analysis. In addition, field hydro-geochemistry focused on sampling techniques and field measurements onsite. Subsequent data analysis

  15. Performance of deep geothermal energy systems

    NASA Astrophysics Data System (ADS)

    Manikonda, Nikhil

    Geothermal energy is an important source of clean and renewable energy. This project deals with the study of deep geothermal power plants for the generation of electricity. The design involves the extraction of heat from the Earth and its conversion into electricity. This is performed by allowing fluid deep into the Earth where it gets heated due to the surrounding rock. The fluid gets vaporized and returns to the surface in a heat pipe. Finally, the energy of the fluid is converted into electricity using turbine or organic rankine cycle (ORC). The main feature of the system is the employment of side channels to increase the amount of thermal energy extracted. A finite difference computer model is developed to solve the heat transport equation. The numerical model was employed to evaluate the performance of the design. The major goal was to optimize the output power as a function of parameters such as thermal diffusivity of the rock, depth of the main well, number and length of lateral channels. The sustainable lifetime of the system for a target output power of 2 MW has been calculated for deep geothermal systems with drilling depths of 8000 and 10000 meters, and a financial analysis has been performed to evaluate the economic feasibility of the system for a practical range of geothermal parameters. Results show promising an outlook for deep geothermal systems for practical applications.

  16. National Geothermal Data System (NGDS) Geothermal Data: Community Requirements and Information Engineering

    SciTech Connect

    Anderson, Arlene; Blackwell, David; Chickering, Cathy; Boyd, Toni; Horne, Roland; MacKenzie, Matthew; Moore, Joseph; Nickull, Duane; Richard, Stephen; Shevenell, Lisa A.

    2013-10-01

    To satisfy the critical need for geothermal data to advance geothermal energy as a viable renewable energy contender, the U.S. Department of Energy is investing in the development of the National Geothermal Data System (NGDS). This paper outlines efforts among geothermal data providers nationwide to supply cutting edge geo-informatics. NGDS geothermal data acquisition, delivery, and methodology are discussed. In particular, this paper addresses the various types of data required to effectively assess geothermal energy potential and why simple links to existing data are insufficient. To create a platform for ready access by all geothermal stakeholders, the NGDS includes a work plan that addresses data assets and resources of interest to users, a survey of data providers, data content models, and how data will be exchanged and promoted, as well as lessons learned within the geothermal community.

  17. Exploration of geothermal systems using hyperspectral thermal infrared remote sensing

    NASA Astrophysics Data System (ADS)

    Reath, Kevin A.; Ramsey, Michael S.

    2013-09-01

    Visible near infrared (VNIR), short-wave infrared (SWIR), and thermal infrared (TIR) remote sensing has long been used for geothermal exploration. Specific focus on the TIR region (8-12 μm) has resulted in major-rock-forming mineral classes being identified and their areal percentages to be more easily mapped due in part to the linear mixing behavior of TIR emission. To understand the mineral compositional and thermal distribution of active geothermal surfaces systems, hyperspectral TIR data from the Spatially Enhanced Broadband Array Spectrograph System (SEBASS) airborne sensor were acquired over the Salton Sea, CA geothermal fields by The Aerospace Corporation on March 26, 2009 and April 6, 2010. SEBASS collects 128 wavelength channels at ~ 1 m spatial resolution. Such high resolution data are rarely available for this type of scientific analysis and enabled the identification of rare mineral assemblages associated with the geothermally-active areas. One surface unit with a unique spectrum, believed to be a magnesium sulfate of unknown hydration state, was identified for the first time in the SEBASS data. The abundance and distribution of this mineral varied between 2009 and 2010 likely due to the precipitation conditions. Data obtained by the SEBASS sensor were also regressed to the 32 channel spectral resolution of the Mineral and Gas Identifier (MAGI) airborne sensor in order to test sensitivity limits. At this lower spectral resolution, all surface minerals were still effectively identified and therefore validated data at MAGI resolution are still very effective for accurate surface compositional mapping. A similar approach used at active geothermal areas in other semi-arid regions around the world has the potential to better characterize transient mineralogy, identify "indicators minerals", understand the influence of surface and ground water, and ultimately to locate new geothermal targets for future exploration. Furthermore, new Mineral and Gas

  18. A Geothermal GIS for Nevada: Defining Regional Controls and Favorable Exploration Terrains for Extensional Geothermal Systems

    USGS Publications Warehouse

    Coolbaugh, M.F.; Taranik, J.V.; Raines, G.L.; Shevenell, L.A.; Sawatzky, D.L.; Bedell, R.; Minor, T.B.

    2002-01-01

    Spatial analysis with a GIS was used to evaluate geothermal systems in Nevada using digital maps of geology, heat flow, young faults, young volcanism, depth to groundwater, groundwater geochemistry, earthquakes, and gravity. High-temperature (>160??C) extensional geothermal systems are preferentially associated with northeast-striking late Pleistocene and younger faults, caused by crustal extension, which in most of Nevada is currently oriented northwesterly (as measured by GPS). The distribution of sparse young (160??C) geothermal systems in Nevada are more likely to occur in areas where the groundwater table is shallow (<30m). Undiscovered geothermal systems may occur where groundwater levels are deeper and hot springs do not issue at the surface. A logistic regression exploration model was developed for geothermal systems, using young faults, young volcanics, positive gravity anomalies, and earthquakes to predict areas where deeper groundwater tables are most likely to conceal geothermal systems.

  19. What is the National Geothermal Data System (NGDS)? Fact Sheet

    SciTech Connect

    U.S. Department of Energy, Office of Energy Efficiency and Renewable Energy

    2012-09-03

    Overview of the National Geothermal Data System, a distributed, interoperable network of data repositories and state geological service providers from across the U.S. and the nation's leading academic geothermal centers.

  20. Convective heat transport in geothermal systems

    SciTech Connect

    Lippmann, M.J.; Bodvarsson, G.S.

    1986-08-01

    Most geothermal systems under exploitation for direct use or electrical power production are of the hydrothermal type, where heat is transferred essentially by convection in the reservoir, conduction being secondary. In geothermal systems, buoyancy effects are generally important, but often the fluid and heat flow patterns are largely controlled by geologic features (e.g., faults, fractures, continuity of layers) and location of recharge and discharge zones. During exploitation, these flow patterns can drastically change in response to pressure and temperature declines, and changes in recharge/discharge patterns. Convective circulation models of several geothermal systems, before and after start of fluid production, are described, with emphasis on different characteristics of the systems and the effects of exploitation on their evolution. Convective heat transport in geothermal fields is discussed, taking into consideration (1) major geologic features; (2) temperature-dependent rock and fluid properties; (3) fracture- versus porous-medium characteristics; (4) single- versus two-phase reservoir systems; and (5) the presence of noncondensible gases.

  1. National Geothermal Data System Hub Deployment Timeline (Appendix E-1-d)

    SciTech Connect

    Caudill, Christy

    2015-12-20

    Excel spreadsheet describing activity, spending, and development for the four data hubs (Arizona Geoloical Survey, Kentucky Geological Survey, Illinois Geological Survey, and Nevada Bureau of Mines and Geology) serving data for the National Geothermal Data System under the State Contributions to the National Geothermal Data System Project.

  2. Induced seismicity associated with enhanced geothermal system

    SciTech Connect

    Majer, Ernest; Majer, Ernest L.; Baria, Roy; Stark, Mitch; Oates, Stephen; Bommer, Julian; Smith, Bill; Asanuma, Hiroshi

    2006-09-26

    Enhanced Geothermal Systems (EGS) offer the potential to significantly add to the world energy inventory. As with any development of new technology, some aspects of the technology has been accepted by the general public, but some have not yet been accepted and await further clarification before such acceptance is possible. One of the issues associated with EGS is the role of microseismicity during the creation of the underground reservoir and the subsequent extraction of the energy. The primary objectives of this white paper are to present an up-to-date review of the state of knowledge about induced seismicity during the creation and operation of enhanced geothermal systems, and to point out the gaps in knowledge that if addressed will allow an improved understanding of the mechanisms generating the events as well as serve as a basis to develop successful protocols for monitoring and addressing community issues associated with such induced seismicity. The information was collected though literature searches as well as convening three workshops to gather information from a wide audience. Although microseismicity has been associated with the development of production and injection operations in a variety of geothermal regions, there have been no or few adverse physical effects on the operations or on surrounding communities. Still, there is public concern over the possible amount and magnitude of the seismicity associated with current and future EGS operations. It is pointed out that microseismicity has been successfully dealt with in a variety of non-geothermal as well as geothermal environments. Several case histories are also presented to illustrate a variety of technical and public acceptance issues. It is concluded that EGS Induced seismicity need not pose any threat to the development of geothermal resources if community issues are properly handled. In fact, induced seismicity provides benefits because it can be used as a monitoring tool to understand the

  3. Advancements in 3D Structural Analysis of Geothermal Systems

    SciTech Connect

    Siler, Drew L; Faulds, James E; Mayhew, Brett; McNamara, David

    2013-06-23

    Robust geothermal activity in the Great Basin, USA is a product of both anomalously high regional heat flow and active fault-controlled extension. Elevated permeability associated with some fault systems provides pathways for circulation of geothermal fluids. Constraining the local-scale 3D geometry of these structures and their roles as fluid flow conduits is crucial in order to mitigate both the costs and risks of geothermal exploration and to identify blind (no surface expression) geothermal resources. Ongoing studies have indicated that much of the robust geothermal activity in the Great Basin is associated with high density faulting at structurally complex fault intersection/interaction areas, such as accommodation/transfer zones between discrete fault systems, step-overs or relay ramps in fault systems, intersection zones between faults with different strikes or different senses of slip, and horse-tailing fault terminations. These conceptualized models are crucial for locating and characterizing geothermal systems in a regional context. At the local scale, however, pinpointing drilling targets and characterizing resource potential within known or probable geothermal areas requires precise 3D characterization of the system. Employing a variety of surface and subsurface data sets, we have conducted detailed 3D geologic analyses of two Great Basin geothermal systems. Using EarthVision (Dynamic Graphics Inc., Alameda, CA) we constructed 3D geologic models of both the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These 3D models allow spatial comparison of disparate data sets in 3D and are the basis for quantitative structural analyses that can aid geothermal resource assessment and be used to pinpoint discrete drilling targets. The relatively abundant data set at Brady’s, ~80 km NE of Reno, NV, includes 24 wells with lithologies interpreted from careful analysis of cuttings and core, a 1

  4. A new classification scheme for deep geothermal systems based on geologic controls

    NASA Astrophysics Data System (ADS)

    Moeck, I.

    2012-04-01

    the characteristics of a geothermal system. The thermal regime and heat flow, hydrogeologic regime, fluid dynamics, fluid chemistry, faults and fractures, stress regime, and lithological sequence are controlled by the plate tectonic framework, hence critical for understanding the geothermal system. It is important to identify if the geothermal system is located at active plate boundaries or in intracontinental tectonically quiescent settings and thus how it relates to both active volcanism and active tectonics.

  5. Use of U and Th Decay-Series Disequilibrium to Characterize Geothermal Systems: An Example from the Coso Geothermal System

    NASA Astrophysics Data System (ADS)

    Leslie, B. W.; Hammond, D.

    2007-12-01

    Uranium and thorium decay series isotopes were measured in fluids and solids in the Coso geothermal system to assess the utility and constrain the limitations of the radioisotopic approach to the investigation of rock-water interaction. Fluid radioisotope measurements indicate substantial kilometer-scale variability in chemistry. Between 1988 and 1990, radium isotope activity ratios indicate temporal variability, which is exhibited by apparent mixing relationships observed as a function of time for single wells. Activity ratios of Ra-224/Ra-226 and Ra- 228/Ra-226, and the processes that contribute and remove these radionuclide to and from the fluids, constrain residence times of fluids and may help constrain fluid velocities in the geothermal system. Activity ratios of Ra- 224/Ra-226 > ten were measured. In groundwater and geothermal systems ratios of Ra-224/Ra-226 > ten are limited to zones of thermal upwelling or very young (days to weeks) waters in mountainous areas. Rn-222 results indicate that radon is also an effective tracer for steam velocities within the geothermal system. Analysis of carbon dioxide and Rn-222 data indicates that the residence time of steam (time since separation from the liquid) is short (probably less than four days). Estimates of fluid velocities derived from Rn-222 and radium isotopic measurements are within an order of magnitude of velocities derived from a fluorescein tracer test. Both Rn-222 and Ra-224 activities are higher in single-phase fluids in the northwest as compared to the southeast, indicating a higher rock-surface-area/water-volume ratio in the northwest. Thus, measurements of short-lived radioisotopes and gaseous phase constituents can constrain processes and characteristics of geothermal systems that are usually difficult to constrain (e.g., surface area/volume, residence times). The NRC staff views expressed herein are preliminary and do not constitute a final judgment or determination of the matters addressed or of

  6. Geothermal Resource Analysis and Structure of Basin and Range Systems, Especially Dixie Valley Geothermal Field, Nevada

    SciTech Connect

    David Blackwell; Kenneth Wisian; Maria Richards; Mark Leidig; Richard Smith; Jason McKenna

    2003-08-14

    Publish new thermal and drill data from the Dizie Valley Geothermal Field that affect evaluation of Basin and Range Geothermal Resources in a very major and positive way. Completed new geophysical surveys of Dizie Valley including gravity and aeromagnetics and integrated the geophysical, seismic, geological and drilling data at Dizie Valley into local and regional geologic models. Developed natural state mass and energy transport fluid flow models of generic Basin and Range systems based on Dizie Valley data that help to understand the nature of large scale constraints on the location and characteristics of the geothermal systems. Documented a relation between natural heat loss for geothermal and electrical power production potential and determined heat flow for 27 different geothermal systems. Prepared data set for generation of a new geothermal map of North American including industry data totaling over 25,000 points in the US alone.

  7. Materials selection guidelines for geothermal energy utilization systems

    SciTech Connect

    Ellis, P.F. II; Conover, M.F.

    1981-01-01

    This manual includes geothermal fluid chemistry, corrosion test data, and materials operating experience. Systems using geothermal energy in El Salvador, Iceland, Italy, Japan, Mexico, New Zealand, and the United States are described. The manual provides materials selection guidelines for surface equipment of future geothermal energy systems. The key chemical species that are significant in determining corrosiveness of geothermal fluids are identified. The utilization modes of geothermal energy are defined as well as the various physical fluid parameters that affect corrosiveness. Both detailed and summarized results of materials performance tests and applicable operating experiences from forty sites throughout the world are presented. The application of various non-metal materials in geothermal environments are discussed. Included in appendices are: corrosion behavior of specific alloy classes in geothermal fluids, corrosion in seawater desalination plants, worldwide geothermal power production, DOE-sponsored utilization projects, plant availability, relative costs of alloys, and composition of alloys. (MHR)

  8. Towards the Understanding of Induced Seismicity in Enhanced Geothermal Systems

    SciTech Connect

    Gritto, Roland; Dreger, Douglas; Heidbach, Oliver

    2014-08-29

    This DOE funded project was a collaborative effort between Array Information Technology (AIT), the University of California at Berkeley (UCB), the Helmholtz Centre Potsdam - German Research Center for Geosciences (GFZ) and the Lawrence Berkeley National Laboratory (LBNL). It was also part of the European research project “GEISER”, an international collaboration with 11 European partners from six countries including universities, research centers and industry, with the goal to address and mitigate the problems associated with induced seismicity in Enhanced Geothermal Systems (EGS). The goal of the current project was to develop a combination of techniques, which evaluate the relationship between enhanced geothermal operations and the induced stress changes and associated earthquakes throughout the reservoir and the surrounding country rock. The project addressed the following questions: how enhanced geothermal activity changes the local and regional stress field; whether these activities can induce medium sized seismicity M > 3; (if so) how these events are correlated to geothermal activity in space and time; what is the largest possible event and strongest ground motion, and hence the potential hazard associated with these activities. The development of appropriate technology to thoroughly investigate and address these questions required a number of datasets to provide the different physical measurements distributed in space and time. Because such a dataset did not yet exist for an EGS system in the United State, we used current and past data from The Geysers geothermal field in northern California, which has been in operation since the 1960s. The research addressed the need to understand the causal mechanisms of induced seismicity, and demonstrated the advantage of imaging the physical properties and temporal changes of the reservoir. The work helped to model the relationship between injection and production and medium sized magnitude events that have

  9. Geothermal down well pumping system

    NASA Technical Reports Server (NTRS)

    Matthews, H. B.; Mcbee, W. D.

    1974-01-01

    A key technical problem in the exploitation of hot water geothermal energy resources is down-well pumping to inhibit mineral precipitation, improve thermal efficiency, and enhance flow. A novel approach to this problem involves the use of a small fraction of the thermal energy of the well water to boil and super-heat a clean feedwater flow in a down-hole exchanger adjacent to the pump. This steam powers a high-speed turbine-driven pump. The exhaust steam is brought to the surface through an exhaust pipe, condensed, and recirculated. A small fraction of the high-pressure clean feedwater is diverted to lubricate the turbine pump bearings and prevent leakage of brine into the turbine-pump unit. A project demonstrating the feasibility of this approach by means of both laboratory and down-well tests is discussed.

  10. Utah State Prison Geothermal System

    SciTech Connect

    Mink, L.R.

    1984-07-01

    A geothermal space heating project was recently completed at the Utah State Prison complex at Crystal Hot Springs located near Murray, Utah. The project was initiated in 1978 as a joint U.S. Department of Energy and State of Utah project. Geologic and geophysical investigations initiated in 1979 consist of surface geologic mapping and aeromagnetic and detailed gravity surveys. This exploration program along with several shallow thermal-gradient holes provided the structural details for a subsequent exploration drilling program. The exploration drilling program involved deepening an existing well (SF-1) to 500 ft (150 m) and drilling a new hole (USP/TH-1) to 1000 ft (300 m) to test the extent of the thermal anomaly. Well SF-1 intersected 175)2)F(79)2)C) temperatures in a low permeable quartzite, and well USP/TH-1 intersected highly fractured quartzite in the lower section of the well. A temperature reversal was noted in USP/TH-1 below 700 ft (213 m) with a maximum temperature of 175)2)F(79)2)C) occurring in the zone from 300 to 700 ft (90 to 215 m). Flow testing of USP/TH-1 indicated the well would flow at 1000 gpm with a sustained flow of 400 gpm at a 3.5 psi drawdown over the heating season. Testing also indicated interference with other nearby wells and thermal springs. Fluid production for space heating of the prison facilities took place during the winter of 1983-84. This production will give more data to refine the calculations of reservoir producibility and provide information on the economics of utilizing geothermal fluids for space heating.

  11. Hydrothermal model of the Momotombo geothermal system, Nicaragua

    SciTech Connect

    Verma, M.P.; Martinez, E.; Sanchez, M.; Miranda, K.

    1996-12-31

    The Momotombo geothermal field is situated on the northern shore of Lake Managua at the foot of the active Momotombo volcano. The field has been producing electricity since 1983 and has an installed capacity of 70 MWe. The results of geological, geochemical and geophysical studies have been reported in various internal reports. The isotopic studies were funded by the International Atomic Energy Agency (IAEA), Vienna to develop a hydrothermal model of the geothermal system. The chemical and stable isotopic data ({delta}{sup 18}O and {delta}D) of the geothermal fluid suggest that the seasonal variation in the production characteristics of the wells is related to the rapid infiltration of local precipitation into the reservoir. The annual average composition of Na{sup +}, K{sup +} and Mg{sup 2+} plotted on the Na-K-Mg triangular diagram presented by Giggenbach (1988) to identify the state of rock-water interaction in geothermal reservoirs, shows that the fluids of almost every well are shifting towards chemically immature water due to reservoir exploitation. This effect is prominent in wells Mt-2, Mt-12, Mt-22 and Mt-27. The local groundwaters including surface water from Lake Managua have much lower tritium concentrations than some of the geothermal well fluids, which have about 6 T.U. The high-tritium wells are located along a fault inferred from a thermal anomaly. The tritium concentration is also higher in fluids from wells close to the lake. This could indicate that older local precipitation waters are stored in a deep layer within the lake and that they are infiltrating into the geothermal reservoir.

  12. Finite-element solutions for geothermal systems

    NASA Technical Reports Server (NTRS)

    Chen, J. C.; Conel, J. E.

    1977-01-01

    Vector potential and scalar potential are used to formulate the governing equations for a single-component and single-phase geothermal system. By assuming an initial temperature field, the fluid velocity can be determined which, in turn, is used to calculate the convective heat transfer. The energy equation is then solved by considering convected heat as a distributed source. Using the resulting temperature to compute new source terms, the final results are obtained by iterations of the procedure. Finite-element methods are proposed for modeling of realistic geothermal systems; the advantages of such methods are discussed. The developed methodology is then applied to a sample problem. Favorable agreement is obtained by comparisons with a previous study.

  13. The Examination of Afyonkarahisar's Geothermal System Corrosion

    NASA Astrophysics Data System (ADS)

    Buyuksagis, A.; Erol, S.

    2013-02-01

    Corrosion and scaling of metal surfaces are the major problems caused by geothermal fluids when metallic structures are used. This article describes a study of corrosion and scaling problems in the Afyonkarahisar Geothermal Heating System (AFJET) in Afyonkarahisar, Turkey. Water analysis, XRD, SEM, EDX, IC, ICP-OES analyses, and electrochemical methods were used in this study. Pentasodium triphosphate (Na5P3O10), maleic anhydride (C4H2O3), and 1,3-benzendisulfonic acid disodium salt (C6H4Na2O6S2) were used as corrosion inhibitors. Tests were carried out using geothermal water from AF11 well. The experimental temperatures were chosen as 298, 333, and 358 K. Inhibitor concentrations were chosen as 1 × 10-1, 1 × 10-2, 1 × 10-3, and 1 × 10-4 mol/dm3. Moreover, mixed inhibitor solutions were prepared using the inhibitor concentrations that showed the best inhibition. The first mixed inhibitor solution showed 96% inhibition. The second mixed inhibitor solution showed 90% inhibition. The tested inhibitors act as anodic inhibitors. XRD analysis shows that there is CaCO3 aragonite scaling in the system. Increasing TDS, alkalinity, and hardness all promote scale formation. The photomicrographs from SEM-EDX and the metallographic microscope show that the tested inhibitors form a protective film on the surface. IC and ICP-OES analyses show that the concentration of Ca2+ is very high, which supports scale formation.

  14. Reconstruction of a pavement geothermal deicing system

    SciTech Connect

    Lund, J.W.

    1999-03-01

    In 1948, US 97 in Klamath Falls, Oregon was routed over Esplanade Street to Main Street and through the downtown area. In order to widen the bridge across the US Bureau of Reclamation A Canal and to have the road cross under the Southern Pacific Railroad main north-south line, a new bridge and roadway were constructed at the beginning of this urban route. Because the approach and stop where this roadway intersected Alameda Ave (now Hwy 50 -- Eastside Bypass) caused problems with traffic getting traction in the winter on an adverse 8% grade, a geothermal experiment in pavement de-icing was incorporated into the project. A grid system within the pavement was connected to a nearby geothermal well using a downhole heat exchanger (DHE). The 419-foot well provided heat to a 50-50 ethylene glycol-water solution that ran through the grid system at about 50 gpm. This energy could provide a relatively snow free pavement at an outside temperature of {minus}10 F and snowfall up to 3 inches per hour, at a heat requirement of 41 Btu/hr/ft{sup 2}. Over time, the well temperature dropped from 143 to 98 F at the surface. The bridge and surface pavement, geothermal well, and associated equipment were modified. This paper describes the modifications.

  15. Tracing Injection Fluids in Engineered Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Rose, P. E.; Leecaster, K.; Mella, M.; Ayling, B.; Bartl, M. H.

    2011-12-01

    The reinjection of produced fluids is crucial to the effective management of geothermal reservoirs, since it provides a mechanism for maintaining reservoir pressures while allowing for the disposal of a toxic byproduct. Tracers are essential to the proper location of injection wells since they are the only known tool for reliably characterizing the flow patterns of recirculated fluids. If injection wells are placed too close to production wells, then reinjected fluids do not have sufficient residence time to extract heat from the reservoir and premature thermal breakthrough results. If injection wells are placed too far away, then the reservoir risks unacceptable pressure loss. Several thermally stable compounds from a family of very detectable fluorescent organic compounds (the naphthalene sulfonates) were characterized and found to be effective for use as geothermal tracers. Through batch-autoclave reactions, their Arrhenius pseudo-first-order decay-rate constants were determined. An analytical method was developed that allows for the laboratory determination of concentrations in the low parts-per-trillion range. Field experiments in numerous geothermal reservoirs throughout the world have confirmed the laboratory findings. Whereas conservative tracers such as the naphthalene sulfonates are effective tools for indicating interwell flow patterns and for measuring reservoir pore volumes, 'reactive' tracers can be used to constrain fracture surface area, which is the effective area for heat extraction. This is especially important for engineered geothermal system (EGS) wells, since reactive tracers can be used to measure fracture surface area immediately after drilling and while the well stimulation equipment is still on site. The reactive properties of these tracers that can be exploited to constrain fracture surface area are reversible sorption, contrasting diffusivity, and thermal decay. Laboratory batch- and flow-reactor experiments in combination with numerical

  16. Blind Geothermal System Exploration in Active Volcanic Environments; Multi-phase Geophysical and Geochemical Surveys in Overt and Subtle Volcanic Systems, Hawai’i and Maui

    SciTech Connect

    Fercho, Steven; Owens, Lara; Walsh, Patrick; Drakos, Peter; Martini, Brigette; Lewicki, Jennifer L.; Kennedy, Burton M.

    2015-08-01

    Suites of new geophysical and geochemical exploration surveys were conducted to provide evidence for geothermal resource at the Haleakala Southwest Rift Zone (HSWRZ) on Maui Island, Hawai’i. Ground-based gravity (~400 stations) coupled with heli-bourne magnetics (~1500 line kilometers) define both deep and shallow fractures/faults, while also delineating potentially widespread subsurface hydrothermal alteration on the lower flanks (below approximately 1800 feet a.s.l.). Multi-level, upward continuation calculations and 2-D gravity and magnetic modeling provide information on source depths, but lack of lithologic information leaves ambiguity in the estimates. Additionally, several well-defined gravity lows (possibly vent zones) lie coincident with magnetic highs suggesting the presence of dike intrusions at depth which may represent a potentially young source of heat. Soil CO2 fluxes were measured along transects across geophysically-defined faults and fractures as well as young cinder cones along the HSWRZ. This survey generally did not detect CO2 levels above background, with the exception of a weak anomalous flux signal over one young cinder cone. The general lack of observed CO2 flux signals on the HSWRZ is likely due to a combination of lower magmatic CO2 fluxes and relatively high biogenic surface CO2 fluxes which mix with the magmatic signal. Similar surveys at the Puna geothermal field on the Kilauea Lower East Rift Zone (KLERZ) also showed a lack of surface CO2 flux signals, however aqueous geochemistry indicated contribution of magmatic CO2 and He to shallow groundwater here. As magma has been intercepted in geothermal drilling at the Puna field, the lack of measured surface CO2 flux indicative of upflow of magmatic fluids here is likely due to effective “scrubbing” by high groundwater and a mature hydrothermal system. Dissolved inorganic carbon (DIC) concentrations, δ13C compositions and 3He/4He values were sampled at Maui from several shallow

  17. Natural radioactivity levels of geothermal waters and their influence on soil and agricultural activities.

    PubMed

    Murat Saç, Müslim; Aydemir, Sercan; Içhedef, Mutlu; Kumru, Mehmet N; Bolca, Mustafa; Ozen, Fulsen

    2014-01-01

    All over the world geothermal sources are used for different purposes. The contents of these waters are important to understand positive/negative effects on human life. In this study, natural radioactivity concentrations of geothermal waters were investigated to evaluate the effect on soils and agricultural activities. Geothermal water samples were collected from the Seferihisar Geothermal Region, and the radon and radium concentrations of these waters were analysed using a collector chamber method. Also soil samples, which are irrigated with geothermal waters, were collected from the surroundings of geothermal areas, and natural radioactivity concentrations of collected samples (U, Th and K) were determined using an NaI(Tl) detector system. The activity concentrations of radon and radium were found to be 0.6-6.0 and 0.1-1.0 Bq l(-1), respectively. Generally, the obtained results are not higher compared with the geothermal waters of the world. The activity concentrations in soils were found to be in the range of 3.3-120.3 Bq kg(-1) for (226)Ra (eU), 0.3-108.5 Bq kg(-1) for (232)Th (eTh), 116.0-850.0 Bq kg(-1) for (40)K (% K).

  18. Temporary Cementitious Sealers in Enhanced Geothermal Systems

    SciTech Connect

    Sugama T.; Pyatina, T.; Butcher, T.; Brothers, L.; Bour, D.

    2011-12-31

    Unlike conventional hydrothennal geothermal technology that utilizes hot water as the energy conversion resources tapped from natural hydrothermal reservoir located at {approx}10 km below the ground surface, Enhanced Geothermal System (EGS) must create a hydrothermal reservoir in a hot rock stratum at temperatures {ge}200 C, present in {approx}5 km deep underground by employing hydraulic fracturing. This is the process of initiating and propagating a fracture as well as opening pre-existing fractures in a rock layer. In this operation, a considerable attention is paid to the pre-existing fractures and pressure-generated ones made in the underground foundation during drilling and logging. These fractures in terms of lost circulation zones often cause the wastage of a substantial amount of the circulated water-based drilling fluid or mud. Thus, such lost circulation zones must be plugged by sealing materials, so that the drilling operation can resume and continue. Next, one important consideration is the fact that the sealers must be disintegrated by highly pressured water to reopen the plugged fractures and to promote the propagation of reopened fractures. In response to this need, the objective of this phase I project in FYs 2009-2011 was to develop temporary cementitious fracture sealing materials possessing self-degradable properties generating when {ge} 200 C-heated scalers came in contact with water. At BNL, we formulated two types of non-Portland cementitious systems using inexpensive industrial by-products with pozzolanic properties, such as granulated blast-furnace slag from the steel industries, and fly ashes from coal-combustion power plants. These byproducts were activated by sodium silicate to initiate their pozzolanic reactions, and to create a cemetitious structure. One developed system was sodium silicate alkali-activated slag/Class C fly ash (AASC); the other was sodium silicate alkali-activated slag/Class F fly ash (AASF) as the binder of temper

  19. Enthalpy restoration in geothermal energy processing system

    DOEpatents

    Matthews, Hugh B.

    1983-01-01

    A geothermal deep well energy extraction system is provided of the general type in which solute-bearing hot water is pumped to the earth's surface from a relatively low temperature geothermal source by transferring thermal energy from the hot water to a working fluid for driving a primary turbine-motor and a primary electrical generator at the earth's surface. The superheated expanded exhaust from the primary turbine motor is conducted to a bubble tank where it bubbles through a layer of sub-cooled working fluid that has been condensed. The superheat and latent heat from the expanded exhaust of the turbine transfers thermal energy to the sub-cooled condensate. The desuperheated exhaust is then conducted to the condenser where it is condensed and sub-cooled, whereupon it is conducted back to the bubble tank via a barometric storage tank. The novel condensing process of this invention makes it possible to exploit geothermal sources which might otherwise be non-exploitable.

  20. The Radiator-Enhanced Geothermal System

    NASA Astrophysics Data System (ADS)

    Hilpert, M.; Marsh, B. D.; Geiser, P.

    2015-12-01

    Standard Enhanced Geothermal Systems (EGS) have repeatedly been hobbled by the inability of rock to conductively transfer heat at rates sufficient to re-supply heat extracted convectively via artificially made fracture systems. At the root of this imbalance is the basic magnitude of thermal diffusivity for most rocks, which severely hampers heat flow once the cooled halos about fractures reach ~0.1 m or greater. This inefficiency is exacerbated by the standard EGS design of mainly horizontally constructed fracture systems with inflow and outflow access at the margins of the fracture network. We introduced an alternative system whereby the heat exchanger mimics a conventional radiator in an internal combustion engine, which we call a Radiator-EGS (i.e., RAD-EGS). The heat exchanger is built vertically with cool water entering the base and hot water extracted at the top. The RAD-EGS itself consists of a family of vertical vanes produced through sequential horizontal drilling and permeability stimulation through propellant fracking. The manufactured fracture zones share the orientation of the natural transmissive fracture system. As below about 700 m, S1 is vertical and the average strike of transmissive fractures parallels SHmax, creating vertical fractures that include S1 and SHmax requires drilling stacked laterals parallel to SHmax. The RAD-EGS is also based on the observation that the longevity of natural hydrothermal systems depends on thermal recharge through heat convection but not heat conduction. In this paper, we present numerical simulations that examine the effects of the depths of the injector and extraction wells, vane size, coolant flow rate, the natural crustal geothermal gradient, and natural regional background flow on geothermal energy extraction.

  1. Numerical models for the evaluation of geothermal systems

    SciTech Connect

    Bodvarsson, G.S.; Pruess, K.; Lippmann, M.J.

    1986-08-01

    We have carried out detailed simulations of various fields in the USA (Bada, New Mexico; Heber, California); Mexico (Cerro Prieto); Iceland (Krafla); and Kenya (Olkaria). These simulation studies have illustrated the usefulness of numerical models for the overall evaluation of geothermal systems. The methodology for modeling the behavior of geothermal systems, different approaches to geothermal reservoir modeling and how they can be applied in comprehensive evaluation work are discussed.

  2. Hydrothermal model of the Momotombo geothermal system, Nicaragua

    SciTech Connect

    Verma, M.P.; Martinez, E.; Sanchez, M.; Miranda, K.; Gerardo, J.Y.; Araguas, L.

    1996-01-24

    The Momotombo geotherinal field is situated on the northern shore of Lake Managua at the foot of the active Momotombo volcano. The field has been producing electricity since 1983 and has an installed capacity of 70 MWe. The results of geological, geochemical and geophysical studies have been reported in various internal reports. The isotopic studies were funded by the International Atomic Energy Agency (IAEA), Vienna to develop a hydrothermal model of the geothermal system. The chemical and stable isotopic data (δ18O and δD) of the geothermal fluid suggest that the seasonal variation in the production characteristics of the wells is related to the rapid infiltration of local precipitation into the reservoir. The annual average composition of Na+, K+ and Mg2+ plotted on the Na- K-Mg triangular diagram presented by Giggenbach (1988) to identify the state of rock-water interaction in geothermal reservoirs, shows that the fluids of almost every well are shifting towards chemically immature water due to resenroir exploitation. This effect is prominent in wells Mt-2. Mt-12, Mt-22 and Mt-27. The local groundwaters including surface water from Lake Managua have much lower tritium concentrations than sonic of the geothermal well fluids, which have about 6 T.U. The high-tritium wells are located along a fault inferred froin a thermal anomaly. The tritium concentration is also higher in fluids from wells close to the lake. This could indicate that older local precipitation waters are stored in a deep layer within the lake and that they are infiltrating into the geothermal reservoir.

  3. Geothermal Systems of the Yellowstone Caldera Field Trip Guide

    SciTech Connect

    Foley, Duncan; Neilson, Dennis L.; Nichols, Clayton R.

    1980-09-08

    Geothermal studies are proceedings on two fronts in the West Yellowstone area. High-temperature resources for the generation of electricity are being sought in the Island Park area, and lower temperatures resources for direct applications, primarily space heating, are being explored for near the town of West Yellowstone. Potential electric geothermal development in the Island Park area has been the subject of widespread publicity over fears of damage to thermal features in Yellowstone Park. At the time of writing this guide, companies have applied for geothermal leases in the Island Park area, but these leases have not yet been granted by the US Forest Service. The Senate is now discussing a bill that would regulate geothermal development in Island Park; outcome of this debate will determine the course of action on the lease applications. The Island Park area was the site of two cycles of caldera activity, with major eruptions at 2.0 and 1.2 million years ago. The US Geological Survey estimates that 16,850 x 10{sup 18} joules of energy may remain in the system. Geothermal resources suitable for direct applications are being sought in the West Yellowstone vicinity by the Montana Bureau of Mines and Geology, under funding from the US Department of Energy. West Yellowstone has a mean annual temperature of 1-2 C. Research thus far suggests that basement rocks in the vicinity are at a depth of about 600 m and are probably similar to the rocks exposed north of Hebgen Lake, where Precambrian, Paleozoic and Mesozoic rocks have been mapped. A few sites with anomalously warm water have been identified near the town. Work is continuing on this project.

  4. Geothermal energy control system and method

    DOEpatents

    Matthews, Hugh B.

    1977-01-01

    A geothermal energy transfer and utilization system makes use of thermal energy stored in hot solute-bearing well water to generate super-heated steam from an injected flow of clean water; the super-heated steam is then used for operating a turbine-driven pump at the well bottom for pumping the hot solute-bearing water at high pressure and in liquid state to the earth's surface, where it is used by transfer of its heat to a closed-loop boiler-turbine-alternator combination for the generation of electrical or other power. Residual concentrated solute-bearing water is pumped back into the earth. The clean cooled water is regenerated at the surface-located system and is returned to the deep well pumping system also for lubrication of a novel bearing arrangement supporting the turbine-driven pump system. The bearing system employs liquid lubricated thrust and radial bearings with all bearing surfaces bathed in clean water serving as a lubricant and maintained under pressure to prevent entry into the bearings of contaminated geothermal fluid, an auxiliary thrust ball bearing arrangement comes into operation when starting or stopping the pumping system.

  5. AASG State Geothermal Data Repository for the National Geothermal Data System.

    2012-01-01

    This Drupal metadata and documents capture and management system is a repository, used for maintenance of metadata which describe resources contributed to the AASG State Geothermal Data System. The repository also provides an archive for files that are not hosted by the agency contributing the resource. Data from all 50 state geological surveys is represented here, and is contributed in turn to the National Geothermal Data System.

  6. Triggered Swarms and Induced Aftershock Sequences in Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Shcherbakov, R.; Turcotte, D. L.; Yikilmaz, M. B.; Kellogg, L. H.; Rundle, J. B.

    2015-12-01

    Natural geothermal systems, which are used for energy generation, are usually associated with high seismic activity. This can be related to the large-scale injection and extraction of fluids to enhance geothermal recovery. This results in the changes of the pore pressure and pore-elastic stress field and can stimulate the occurrence of earthquakes. These systems are also prone to triggering of seismicity by the passage of seismic waves generated by large distant main shocks. In this study, we analyze clustering and triggering of seismicity at several geothermal fields in California. Particularly, we consider the seismicity at the Geysers, Coso, and Salton Sea geothermal fields. We analyze aftershock sequences generated by local large events with magnitudes greater than 4.0 and earthquake swarms generated by several significant long distant main shocks. We show that the rate of the aftershock sequences generated by the local large events in the two days before and two days after the reference event can be modelled reasonably well by the time dependent Epidemic Type Aftershock Sequence (ETAS) model. On the other hand, the swarms of activity triggered by large distant earthquakes cannot be described by the ETAS model. To model the increase in the rate of seismicity associated with triggering by large distant main shocks we introduce an additional time-dependent triggering mechanism into the ETAS model. In almost all cases the frequency-magnitude statistics of triggered sequences follow Gutenberg-Richter scaling to a good approximation. The analysis indicates that the seismicity triggered by relatively large local events can initiate sequences similar to regular aftershock sequences. In contrast, the distant main shocks trigger swarm like activity with faster decaying rates.

  7. Geothermal systems in volcanic arcs: Volcanic characteristics and surface manifestations as indicators of geothermal potential and favorability worldwide

    NASA Astrophysics Data System (ADS)

    Stelling, P.; Shevenell, L.; Hinz, N.; Coolbaugh, M.; Melosh, G.; Cumming, W.

    2016-09-01

    This paper brings a global perspective to volcanic arc geothermal assessments by evaluating trends and correlations of volcanic characteristic and surface manifestation data from world power production sites in subduction zone volcanic settings. The focus of the work was to evaluate volcanic centers individually and as a group in these arcs by correlating various geologic characteristics with known potential to host electricity grade geothermal systems at the volcanic centers. A database was developed that describes key geologic factors expected to be indicative of productive geothermal systems in a global training set, which includes all 74 subduction zone volcanic centers world-wide with current or proven power production capability. Importantly, this data set only contains data from subduction zone volcanoes and contains no negative cases, limiting the populations of any statistical groups. Regardless, this is the most robust geothermal benchmark training set for magmatic-heated systems to date that has been made public. The work reported here is part of a larger project that included data collection, evaluation, correlations and weightings, fairway and favorability modeling and mapping, prediction of blind systems, and uncertainty analysis to estimate errors associated with model predictions. This first paper describes volcano characteristics, compositions and eruption ages and trends along with surface manifestation observations and temperatures as they relate to known power producing systems. Our findings show a strong correlation between the presence and size of active flank fumarole areas and installed power production. Additionally, the majority of volcanic characteristics, including long-held anecdotal correlations related to magmatic composition or size, have limited to no correlation with power production potential. Notable exceptions are correlations between greater power yield from geothermal systems associated with older (Pleistocene) caldera systems

  8. Choosing a Geothermal as an HVAC System.

    ERIC Educational Resources Information Center

    Lensenbigler, John D.

    2002-01-01

    Describes the process of selecting and installing geothermal water source heat pumps for new residence halls at Johnson Bible College in Knoxville, Tennessee, including choosing the type of geothermal design, contractors, and interior equipment, and cost and payback. (EV)

  9. ELVIS: Multi-Electrolyte Aqueous Activity Model for Geothermal Solutions

    NASA Astrophysics Data System (ADS)

    Hingerl, F. F.; Wagner, T.; Driesner, T.; Kulik, D. A.; Kosakowski, G.

    2011-12-01

    High temperature, pressure, and fluid salinities render geochemical modeling of fluid-rock interactions in Enhanced Geothermal Systems a demanding task. Accurate prediction of fluid-mineral equilibria strongly depends on the availability of thermodynamic data and activity models. Typically, the Pitzer activity model is applied for geothermal fluids. A drawback of this model is the large number of parameters required to account for temperature and pressure dependencies, which significantly reduces computational efficiency of reactive transport simulations. In addition, most available parameterizations are valid only at vapor-saturated conditions. As an alternative we implemented the EUNIQUAC local composition model [2] that needs substantially fewer fitting parameters. However, the current EUNIQUAC model design does not include provision for high temperature (>150°C) applications and lacks a formulation for pressure dependence. Therefore, its application to geothermal conditions requires a re-formulation and re-fitting of the model. We developed a new tool termed GEMSFIT that allows generic fitting of activity models (for aqueous electrolyte and non-electrolyte solutions) and equations of state implemented in our geochemical equilibrium solver GEM-Selektor (http://gems.web.psi.ch). GEMSFIT combines a PostgreSQL database for storing and managing the datasets of experimental measurements and interaction parameters, the parallelized genetic algorithm toolbox of MATLAB° for the parameter fitting, and an interface to the numerical kernel of GEM-Selektor to access activity models and perform chemical equilibrium calculations. Benchmarking of the partly re-parameterized EUNIQUAC model against Pitzer revealed that the former is less accurate, which can result in incorrect predictions of mineral precipitation/dissolution. Consequently, we modified the EUNIQUAC model and concurrently introduced a pressure dependence to be able to fit experimental data over wide ranges of

  10. Tracers for Characterizing Enhanced Geothermal Systems

    SciTech Connect

    Karen Wright; George Redden; Carl D. Palmer; Harry Rollins; Mark Stone; Mason Harrup; Laurence C. Hull

    2010-02-01

    Information about the times of thermal breakthrough and subsequent rates of thermal drawdown in enhanced geothermal systems (EGS) is necessary for reservoir management, designing fracture stimulation and well drilling programs, and forecasting economic return. Thermal breakthrough in heterogeneous porous media can be estimated using conservative tracers and assumptions about heat transfer rates; however, tracers that undergo temperature-dependent changes can provide more detailed information about the thermal profile along the flow path through the reservoir. To be effectively applied, the thermal reaction rates of such temperature sensitive traces must be well characterized for the range of conditions that exist in geothermal systems. Reactive tracers proposed in the literature include benzoic and carboxylic acids (Adams) and organic esters and amides (Robinson et al.); however, the practical temperature range over which these tracers can be applied (100-275°C) is somewhat limited. Further, for organic esters and amides, little is known about their sorption to the reservoir matrix and how such reactions impact data interpretation. Another approach involves tracers where the reference condition is internal to the tracer itself. Two examples are: 1) racemization of polymeric amino acids, and 2) mineral thermoluminescence. In these cases internal ratios of states are measured rather than extents of degradation and mass loss. Racemization of poly-L-lactic acid (for example) is temperature sensitive and therefore can be used as a temperature-recording tracer depending on the rates of racemization and stability of the amino acids. Heat-induced quenching of thermoluminescence of pre-irradiated LiF can also be used. To protect the tracers from alterations (extraneous reactions, dissolution) in geothermal environments we are encapsulating the tracers in core-shell colloidal structures that will subsequently be tested for their ability to be transported and to protect the

  11. Ground Energy Balance For Shallow Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Bayer, P.; Rivera, J.

    2015-12-01

    Vertical borehole heat exchangers (BHE) represent the most common applications by far in the field of shallow geothermal energy. They are typically operated for decades for energy extraction from the top 400 m of the subsurface. During this lifetime, thermal anomalies are generated in the ground and surface-near aquifers. These anomalies often grow over the years and compromise the overall performance of the geothermal system. As a basis for prediction and control of the developing energy imbalance in the ground, the focus is often set on the ground temperatures. This is reflected, for instance, in regulative temperature thresholds. As an alternative to temperature, we examine the temporal and spatial variability of heat fluxes and power sources during geothermal heat pump operation. The underlying idea is that knowledge of the primary heat sources is fundamental for the control of ground temperature evolution. For analysis of heat fluxes, an analytical framework for BHE simulation based on Kelvin's line source is re-formulated. This is applied to a synthetic study and for modelling a long-term application in the field. Our results show that during early operation phase, energy is extracted mainly from the underground. Local depletion at the borehole enhances the vertical fluxes with the relative contribution from the bottom reaching a limit of 24 % of the total power demand. The relative contribution from the ground surface becomes dominant for Fourier numbers larger than 0.13. For the full life cycle, vertical heat flux from the ground surface dominates the basal heat flux towards the BHE and it provides about two thirds of the demanded power. Finally, we reveal that the time for ground energy recovery after BHE shutdown may be longer than what is expected from simulated temperature trends.

  12. National Geothermal Data System: A Geothermal Data System for Exploration and Development

    SciTech Connect

    Allison, Lee; Richard, Stephen; Patten, Kim; Love, Diane; Coleman, Celia; Chen, Genhan

    2012-09-30

    Geothermal-relevant geosciences data from all 50 states (www.stategeothermaldata.org), federal agencies, national labs, and academic centers are being digitized and linked in a distributed online network funded by the U.S. Department of Energy Geothermal Data System (GDS) to foster geothermal energy exploration and development through use of interactive online ‘mashups,’data integration, and applications. Emphasis is first to make as much information as possible accessible online, with a long range goal to make data interoperable through standardized services and interchange formats. A growing set of more than thirty geoscience data content models is in use or under development to define standardized interchange formats for: aqueous chemistry, borehole temperature data, direct use feature, drill stem test, seismic event hypocenter, fault feature, geologic contact feature, geologic unit feature, thermal/hot spring description, metadata, quaternary fault, volcanic vent description, well header feature, borehole lithology log, crustal stress, gravity, heat flow/temperature gradient, permeability, and feature description data like developed geothermal systems, geologic unit geothermal characterization, permeability, production data, rock alteration description, rock chemistry, and thermal conductivity. Map services are also being developed for isopach maps, aquifer temperature maps, and several states are working on geothermal resource overview maps. Content models are developed based on existing community datasets to encourage widespread adoption and promulgate content quality standards. Geoscience data and maps from other GDS participating institutions, or “nodes” (e.g., U.S. Geological Survey, Southern Methodist University, Oregon Institute of Technology, Stanford University, the University of Utah) are being supplemented with extensive land management and land use resources from the Western Regional Partnership (15 federal agencies and 5 Western states) to

  13. Geothermal energy control system and method

    DOEpatents

    Matthews, Hugh B.

    1976-01-01

    A geothermal energy transfer and utilization system makes use of thermal energy stored in hot solute-bearing well water to generate super-heated steam from an injected flow of clean water; the super-heated steam is then used for operating a turbine-driven pump at the well bottom for pumping the hot solute-bearing water at high pressure and in liquid state to the earth's surface, where it is used by transfer of its heat to a closed-loop boiler-turbine-alternator combination for the generation of electrical or other power. Residual concentrated solute-bearing water is pumped back into the earth. The clean cooled water is regenerated at the surface-located system and is returned to the deep well pumping system also for lubrication of a novel bearing arrangement supporting the turbine-driven pump system.

  14. Quantitative Risk Assessment for Enhanced Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Lowry, T. S.; McKenna, S. A.; Hadgu, T.; Kalinina, E.

    2011-12-01

    This study uses a quantitative risk-assessment approach to place the uncertainty associated with enhanced geothermal systems (EGS) development into meaningful context and to identify points of attack that can reduce risk the most. Using the integrated geothermal assessment tool, GT-Mod, we calculate the complimentary cumulative distribution function of the levelized cost of electricity (LCOE) that results from uncertainty in a variety of geologic and economic input parameter values. EGS is a developing technology that taps deep (2-10km) geologic heat sources for energy production by "enhancing" non-permeable hot rock through hydraulic stimulation. Despite the promise of EGS, uncertainties in predicting the physical end economic performance of a site has hindered its development. To address this, we apply a quantitative risk-assessment approach that calculates risk as the sum of the consequence, C, multiplied by the range of the probability, ΔP, over all estimations of a given exceedance probability, n, over time, t. The consequence here is defined as the deviation from the best estimate LCOE, which is calculated using the 'best-guess' input parameter values. The analysis assumes a realistic but fictitious EGS site with uncertainties in the exploration success rate, the sub-surface thermal gradient, the reservoir fracture pattern, and the power plant performance. Uncertainty in the exploration, construction, O&M, and drilling costs are also included. The depth to the resource is calculated from the thermal gradient and a target resource temperature of 225 °C. Thermal performance is simulated using the Gringarten analytical solution. The mass flow rate is set to produce 30 MWe of power for the given conditions and is adjusted over time to maintain that rate over the plant lifetime of 30 years. Simulations are conducted using GT-Mod, which dynamically links the physical systems of a geothermal site to simulate, as an integrated, multi-system component, the

  15. Mantle helium and carbon isotopes in Separation Creek Geothermal Springs, Three Sisters area, Central Oregon: Evidence for renewed volcanic activity or a long term steady state system?

    SciTech Connect

    van Soest, M.C.; Kennedy, B.M.; Evans, W.C.; Mariner, R.H.

    2002-04-30

    Cold bubbling springs in the Separation Creek area, the locus of current uplift at South Sister volcano show strong mantle signatures in helium and carbon isotopes and CO{sub 2}/{sup 3}He. This suggests the presence of fresh basaltic magma in the volcanic plumbing system. Currently there is no evidence to link this system directly to the uplift, which started in 1998. To the contrary, all geochemical evidence suggests that there is a long-lived geothermal system in the Separation Creek area, which has not significantly changed since the early 1990s. There was no archived helium and carbon data, so a definite conclusion regarding the strong mantle signature observed in these tracers cannot yet be drawn. There is a distinct discrepancy between the yearly magma supply required to explain the current uplift (0.006 km{sup 3}/yr) and that required to explain the discharge of CO{sub 2} from the system (0.0005 km{sup 3}/yr). This discrepancy may imply that the chemical signal associated with the increase in magma supply has not reached the surface yet. With respect to this the small changes observed at upper Mesa Creek require further attention, due to the recent volcanic vent in that area it may be the location were the chemical signal related to the uplift can most quickly reach the surface. Occurrence of such strong mantle signals in cold/diffuse geothermal systems suggests that these systems should not be ignored during volcano monitoring or geothermal evaluation studies. Although the surface-expression of these springs in terms of heat is minimal, the chemistry carries important information concerning the size and nature of the underlying high-temperature system and any changes taking place in it.

  16. Active and Fossil Geothermal Activity at Lake Chapala, Mexico

    NASA Astrophysics Data System (ADS)

    Zârate-del Vall, P.

    2002-12-01

    Geothermal systems are very abundant in the tectonically active zones of the earth's crust and the Citala rift, where Lake Chapala is located, is not the exception. The Lake Chapala basin is characterized by its paleo- and actual geothermal activity that includes: thermal springs, fossil sinter deposits and hydrothermal petroleum manifestations. Thermal springs occur both inside and outside the lake. The spring water in out-shore thermal springs around Lake Chapala is carbonate (Medina-Heredia A, 1986). To the NE area is San Luis Agua Caliente (69°C; ~ 240 mg L-1 [HCO3]1) in the NW at Jocotepec (36°C; ~263mg L-1 [HCO3]-); in the South we find Tuxcueca and Tizap n El Alto (30°C; 193 mg L-1 [HCO3]-). However, there is an exception, the spring water at the San Juan Cosal sector (North), which is sulfate (64-83°C; ~479 mg L-1, [SO4]-2). Examples of in-shore thermal springs are "Los Gorgos" (near South shore) and "El Fuerte" (near East shore and temporary "out-shore" because of actual severe drought); the characterisation of water of this in-shore sites is in progress. On the SE shore and five km NW from Regules village, outcrops a carbonate deposit named "La Calera". This carbonate fossil sinter outcrops 2 km in E-W direction and 600 m in N-S direction and overlays andesitic rock. With a thickness of approximately 5m and a roughly horizontal attitude, the carbonated sinter material is characterized by both massive and banded structure. When massive, it is colored in yellow brownish and grey and elsewhere it shows a pseudo-brecciated structure and when banded, alternated of yellow and dark millimetre bands can be seen; is characterized by vuggy porosity and silica (quartz and chalcedony) vein lets. Under microscope a pseudo-micritic texture is observed; vugs coated by iron oxides, are filled with calcite, and/or quartz, chalcedony and clay minerals. Six samples of carbonate of "La Calera" deposit were analysed for their stable isotopes (LODC-UParis VI). From δ 13

  17. GEOTHERM Data Set

    DOE Data Explorer

    DeAngelo, Jacob

    1983-01-01

    GEOTHERM is a comprehensive system of public databases and software used to store, locate, and evaluate information on the geology, geochemistry, and hydrology of geothermal systems. Three main databases address the general characteristics of geothermal wells and fields, and the chemical properties of geothermal fluids; the last database is currently the most active. System tasks are divided into four areas: (1) data acquisition and entry, involving data entry via word processors and magnetic tape; (2) quality assurance, including the criteria and standards handbook and front-end data-screening programs; (3) operation, involving database backups and information extraction; and (4) user assistance, preparation of such items as application programs, and a quarterly newsletter. The principal task of GEOTHERM is to provide information and research support for the conduct of national geothermal-resource assessments. The principal users of GEOTHERM are those involved with the Geothermal Research Program of the U.S. Geological Survey.

  18. Combined cycle power unit with a binary system based on waste geothermal brine at Mutnovsk geothermal power plant

    NASA Astrophysics Data System (ADS)

    Tomarov, G. V.; Shipkov, A. A.; Nikol'skii, A. I.; Semenov, V. N.

    2016-06-01

    The Russian geothermal power systems developed in the last few decades outperform their counterparts around the world in many respects. However, all Russian geothermal power stations employ steam as the geothermal fluid and discard the accompanying geothermal brine. In reality, the power of the existing Russian geothermal power stations may be increased without drilling more wells, if the waste brine is employed in combined cycle systems with steam and binary turbine units. For the example of the 50 MW Mutnovsk geothermal power plant, the optimal combined cycle power unit based on the waste geothermal brine is considered. It is of great interest to determine how the thermodynamic parameters of the secondary steam in the expansion unit and the pressure in the condenser affect the performance of the equipment in the combined cycle power unit at Mutnovsk geothermal power plant. For the utilization of the waste geothermal brine at Mutnovsk geothermal power plant, the optimal air temperature in the condensers of the combined cycle power unit is +5°C. The use of secondary steam obtained by flashing of the geothermal brine at Mutnovsk geothermal power plant 1 at a pressure of 0.2 MPa permits the generation of up to 8 MW of electric power in steam turbines and additional power of 5 MW in the turbines of the binary cycle.

  19. Mapping temperature and radiant geothermal heat flux anomalies in the Yellowstone geothermal system using ASTER thermal infrared data

    USGS Publications Warehouse

    Vaughan, R. Greg; Lowenstern, Jacob B.; Keszthelyi, Laszlo P.; Jaworowski, Cheryl; Heasler, Henry

    2012-01-01

    The purpose of this work was to use satellite-based thermal infrared (TIR) remote sensing data to measure, map, and monitor geothermal activity within the Yellowstone geothermal area to help meet the missions of both the U.S. Geological Survey Yellowstone Volcano Observatory and the Yellowstone National Park Geology Program. Specifically, the goals were to: 1) address the challenges of remotely characterizing the spatially and temporally dynamic thermal features in Yellowstone by using nighttime TIR data from the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) and 2) estimate the temperature, geothermal radiant emittance, and radiant geothermal heat flux (GHF) for Yellowstone’s thermal areas (both Park wide and for individual thermal areas). ASTER TIR data (90-m pixels) acquired at night during January and February, 2010, were used to estimate surface temperature, radiant emittance, and radiant GHF from all of Yellowstone’s thermal features, produce thermal anomaly maps, and update field-based maps of thermal areas. A background subtraction technique was used to isolate the geothermal component of TIR radiance from thermal radiance due to insolation. A lower limit for the Yellowstone’s total radiant GHF was established at ~2.0 GW, which is ~30-45% of the heat flux estimated through geochemical (Cl-flux) methods. Additionally, about 5 km2 was added to the geodatabase of mapped thermal areas. This work provides a framework for future satellite-based thermal monitoring at Yellowstone as well as exploration of other volcanic / geothermal systems on a global scale.

  20. The significance of "geothermal microzonation" for the correct planning of low-grade source geothermal systems

    NASA Astrophysics Data System (ADS)

    Viccaro, Marco; Pezzino, Antonino; Belfiore, Giuseppe Maria; Campisano, Carlo

    2016-04-01

    Despite the environmental-friendly energy systems are solar thermal technologies, photovoltaic and wind power, other advantageous technologies exist, although they have not found wide development in countries such as Italy. Given the almost absent environmental impact and the rather favorable cost/benefit ratio, low-enthalpy geothermal systems are, however, likely to be of strategic importance also in Italy during the next years. The importance of geology for a sustainable exploitation of the ground through geothermal systems from low-grade sources is becoming paramount. Specifically, understanding of the lithological characteristics of the subsurface along with structures and textures of rocks is essential for a correct planning of the probe/geo-exchanger field and their associated ground source heat pumps. The complex geology of Eastern Sicily (Southern Italy), which includes volcanic, sedimentary and metamorphic units over limited extension, poses the question of how thermal conductivity of rocks is variable at the scale of restricted areas (even within the same municipality). This is the innovative concept of geothermal microzonation, i.e., how variable is the geothermal potential as a function of geology at the microscale. Some pilot areas have been therefore chosen to test how the geological features of the subsurface can influence the low-enthalpy geothermal potential of an area. Our geologically based evaluation and micro-zonation of the low-grade source geothermal potential of the selected areas have been verified to be fundamental for optimization of all the main components of a low-enthalpy geothermal system. Saving realization costs and limiting the energy consumption through correct sizing of the system are main ambitions to have sustainable development of this technology with intensive utilization of the subsurface. The variegated territory of countries such as Italy implies that these goals can be only reached if, primarily, the geological features

  1. 3D characterization of a Great Basin geothermal system: Astor Pass, NV

    SciTech Connect

    Siler, Drew L; Brett, Mayhew; Faulds, James E

    2012-12-03

    The Great Basin exhibits both anomalously high heat flow (~75±5 mWm-2) and active faulting and extension resulting in robust geothermal activity. There are ~430 known geothermal systems in the Great Basin, with evidence suggesting that undiscovered blind geothermal systems may actually represent the majority of geothermal activity. These systems employ discrete fault intersection/interaction areas as conduits for geothermal circulation. Recent studies show that steeply dipping normal faults with step-overs, fault intersections, accommodation zones, horse-tailing fault terminations and transtensional pull-aparts are the most prominent structural controls of Great Basin geothermal systems. These fault geometries produce sub-vertical zones of high fault and fracture density that act as fluid flow conduits. Structurally controlled fluid flow conduits are further enhanced when critically stressed with respect to the ambient stress conditions. The Astor Pass blind geothermal system, northwestern Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Along this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range. As such, the Astor Pass area lies in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and more northerly striking normal faults. The Astor Pass tufa tower implies the presence of a blind geothermal system. Previous studies suggest that deposition of the Astor Pass tufa was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal fault. Subsequent drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming the presence of a blind geothermal system at Astor Pass. Expanding upon previous work and employing additional detailed geologic mapping, interpretation of 2D seismic reflection data and analysis of well cuttings, a 3

  2. Geology of the Rotorua geothermal system

    SciTech Connect

    Wood, C.P. )

    1992-04-01

    This paper discusses the Rotorua geothermal system located in the south part of Rotorua Caldera, which collapsed during and after the eruption of Mamaku Ignimbrite some 140 ka ago. Drillholes provide geological and hydrological information to 300 m depth. The Mamaku Ignimbrite aquifer has been drilled in the east and south of the field where it contains fluid at or near boiling point. The Ignimbrite drops from south to north across exposed and buried caldera collapse scarps. Rotorua City domes comprise a buried N-S ridge rising at either end to form north and south domes; both contain mostly sub-boiling water up to 190{degrees} C which flows laterally through the outer 40 m of permeably rhyolite as indicated by temperature data. The Fenton Park aquifer comprises sands and gravels in the shallow sedimentary sequence which contain hot water derived possibly from Whakarewarewa, the south dome or the Rotoatamaheke Fault.

  3. Design, construction and evaluation of a simulated geothermal flow system

    SciTech Connect

    Mackanic, J.C.

    1980-07-28

    A system was designed and built to simulate the flow from a geothermal well. The simulated flow will be used to power a Lysholm engine, the performance of which will then be evaluated for different simulated geothermal flows. Two main subjects are covered: 1) the design, construction and evaluation of the behavior of the system that simulates the geothermal flow; included in that topic is a discussion of the probable behavior of the Lysholm engine when it is put into operation, and 2) the investigation of the use of dynamic modeling techniques to determine whether they can provide a suitable means for predicting the behavior of the system.

  4. A Technology Roadmap for Strategic Development of Enhanced Geothermal Systems

    SciTech Connect

    Ziagos, John; Phillips, Benjamin R.; Boyd, Lauren; Jelacic, Allan; Stillman, Greg; Hass, Eric

    2013-02-13

    Realization of EGS development would make geothermal a significant contender in the renewable energy portfolio, on the order of 100+ GWe in the United States alone. While up to 90% of the geothermal power resource in the United States is thought to reside in Enhanced Geothermal Systems (EGS), hurdles to commercial development still remain. The Geothermal Technologies Office, U.S. Department of Energy (DOE), began in 2011 to outline opportunities for advancing EGS technologies on five- to 20-year timescales, with community input on the underlying technology needs that will guide research and ultimately determine commercial success for EGS. This report traces DOE's research investments, past and present, and ties them to these technology needs, forming the basis for an EGS Technology Roadmap to help guide future DOE research. This roadmap is currently open for public comment. Send your comments to geothermal@ee.doe.gov.

  5. United Nations geothermal activities in developing countries

    SciTech Connect

    Beredjick, N.

    1987-07-01

    The United Nations implements technical cooperation projects in developing countries through its Department of Technical Cooperation for Development (DTCD). The DTCD is mandated to explore for and develop natural resources (water, minerals, and relevant infrastructure) and energy - both conventional and new and renewable energy sources. To date, the United Nations has been involved in over 30 geothermal exploration projects (completed or underway) in 20 developing countries: 8 in Africa (Djibouti, Ethiopia, Kenya, Madagascar); 8 in Asia (China, India, Jordan, Philippines, Thailand); 9 in Latin America (Bolivia, Chile, El Salvador, Honduras, Mexico, Nicaragua, Panama) and 6 in Europe (Greece, Romania, Turkey, Yugoslavia). Today, the DTCD has seven UNDP geothermal projects in 6 developing countries. Four of these (Bolivia, China, Honduras, and Kenya) are major exploration projects whose formulation and execution has been possible thanks to the generous contributions under cost-sharing arrangements from the government of Italy. These four projects are summarized.

  6. Geothermal monitor report

    NASA Astrophysics Data System (ADS)

    1982-06-01

    Geothermal Progress Monitor Report No. 6 presents a state-by-state summary of the status of geothermal leasing, exploration, and development in major physiographic regions where geothermal resource potential has been identified. Recent state-specific activities are reported at the end of each state status report, while recent activities of a more general nature are summarized briefly in Part 2 of the report. A list of recent publications of potential interest to the geothermal community and a directory of contributors to the geothermal progress monitoring system are also included.

  7. Double-diffusive convection in geothermal systems: the salton sea, California, geothermal system as a likely candidate

    USGS Publications Warehouse

    Fournier, R.O.

    1990-01-01

    Much has been published about double-diffusive convection as a mechanism for explaining variations in composition and temperature within all-liquid natural systems. However, relatively little is known about the applicability of this phenomenon within the heterogeneous rocks of currently active geothermal systems where primary porosity may control fluid flow in some places and fractures may control it in others. The main appeal of double-diffusive convection within hydrothermal systems is-that it is a mechanism that may allow efficient transfer of heat mainly by convection, while at the same time maintaining vertical and lateral salinity gradients. The Salton Sea geothermal system exhibits the following reservoir characteristics: (1) decreasing salinity and temperature from bottom to top and center toward the sides, (2) a very high heat flow from the top of the system that seems to require a major component of convective transfer of heat within the chemically stratified main reservoir, and (3) a relatively uniform density of the reservoir fluid throughout the system at all combinations of subsurface temperature, pressure, and salinity. Double-diffusive convection can account for these characteristics very nicely whereas other previously suggested models appear to account either for the thermal structure or for the salinity variations, but not both. Hydrologists, reservoir engineers, and particularly geochemists should consider the possibility and consequences of double-diffusive convection when formulating models of hydrothermal processes, and of the response of reservoirs to testing and production. ?? 1990.

  8. Investigation of the Mount Tongariro, New Zealand, geothermal system through Self Potential mapping

    NASA Astrophysics Data System (ADS)

    Miller, C. A.

    2013-12-01

    Mount Tongariro volcano is a composite of overlapping vents active since c. 275 ka with 6 main periods of cone building. The volcano hosts an active geothermal system thought to be vapour dominated with a capping condensate layer; active surface geothermal features are present at Ketetahi, Red Crater, Central Crater and Te Maari Craters. Mount Tongariro erupted twice at Upper Te Maari Crater in 2012 after 125 years of dormancy. The first eruption (August 6th) is thought to be triggered from uncapping of the geothermal system by a landslide caused by pore pressure changes due to dyke intrusion. In response to those eruptions I undertook a combined Self Potential (SP), soil CO2 and ground temperature survey to learn more about the geothermal system, its distribution and fluid flow patterns. Analysis of SP vs. topographic gradient delineated the Ketetahi and Red Crater geothermal surface features. I propose that low pH fluids, combined with hydrothermally altered and therefore electrically conductive ground are the dominate cause of subdued SP anomalies around these features. I interpret a large positive anomaly (+1100 mV) in Oturere Valley, which has no surface geothermal activity, to result from deepening of a ground water aquifer beneath a thick electrically resistive lava flow. Subsequent modelling of SP data to estimate both water table depth, and depth to a potential current source agree with the inferred thickness of the Oturere Valley lava flow, and imply that the lava flow is a poor aquifer. Therefore underlying material hosts the aquifer. Finally I interpret a large negative (-600 mV) SP anomaly on the NE flank of North Crater as a zone of down flowing meteoric fluids, situated outside of the geothermal system. The geothermal surface features with subdued SP anomalies resulting from low pH fluids and conductive hydrothermally altered ground, map zones of weakened rock. These zones may be prone to future flank collapse, especially in areas of steep topography

  9. Investigation of Induced Seismicity from a Geothermal System, Neal Hot Springs, Eastern Oregon

    NASA Astrophysics Data System (ADS)

    Brenn, G. R.; Liberty, L. M.; Van Wijk, K.; Shaltry, D.; Colwell, C.

    2012-12-01

    Newly acquired geophysical data from an eleven-seismometer network surrounding the Neal Hot Springs (NHS) Geothermal Power Plant in eastern Oregon was analyzed for induced seismicity and geothermal fluid flow. Major faults associated with the Oregon-Idaho Graben and the western Snake River Plain provides pathways for deep geothermal fluid flow for the NHS hot-water system. Our short-period seismic stations, can detect regional events not in published earthquake catalogs. These stations have been collecting seismic data from the initiation of the geothermal system's development through fluid injection tests this past summer. Background seismic values were acquired before plant production to measure natural geothermal fluid activity, but no natural fluid flow seismicity was identified. Two local events located less than 10 km to the northeast of NHS along with a catalogued, 2.8 M regional event 200 km away were identified in the data set, verifying the sensitivity and capability of the passive seismic network to capture events that were to occur at NHS. We monitored seismic activity from production and development with 4-8 hour durations for the past 15 months. We identify repeated signals at approximately 2 Hz that likely represent fluid injection or drilling cycles. However, induced earthquakes were not identified during production activities. The lack of microseismic events could be the result of the shallow depth of the geothermal resource, approximately 850 m below the earth surface. Future studies include a receiver function analysis to determine crustal boundaries beneath NHS, along with further monitoring of induced seismicity due to geothermal fluid flow as the geothermal power plant comes online.

  10. Heat pump assisted geothermal heating system for Felix Spa, Romania

    SciTech Connect

    Rosca, Marcel; Maghiar, Teodor

    1996-01-24

    The paper presents a pre-feasibility type study of a proposed heat pump assisted geothermal heating system for an average hotel in Felix Spa, Romania. After a brief presentation of the geothermal reservoir, the paper gives the methodology and the results of the technical and economical calculations. The technical and economical viability of the proposed system is discussed in detail in the final part of the paper.

  11. Further Developments on the Geothermal System Scoping Model: Preprint

    SciTech Connect

    Antkowiak, M.; Sargent, R.; Geiger, J. W.

    2010-07-01

    This paper discusses further developments and refinements for the uses of the Geothermal System Scoping Model in an effort to provide a means for performing a variety of trade-off analyses of surface and subsurface parameters, sensitivity analyses, and other systems engineering studies in order to better inform R&D direction and investment for the development of geothermal power into a major contributor to the U.S. energy supply.

  12. San Diego Gas and Electric Company Imperial Valley geothermal activities

    NASA Technical Reports Server (NTRS)

    Hinrichs, T. C.

    1974-01-01

    San Diego Gas and Electric and its wholly owned subsidiary New Albion Resources Co. have been affiliated with Magma Power Company, Magma Energy Inc. and Chevron Oil Company for the last 2-1/2 years in carrying out geothermal research and development in the private lands of the Imperial Valley. The steps undertaken in the program are reviewed and the sequence that must be considered by companies considering geothermal research and development is emphasized. Activities at the south end of the Salton Sea and in the Heber area of Imperial Valley are leading toward development of demonstration facilities within the near future. The current status of the project is reported.

  13. Design Considerations for Artificial Lifting of Enhanced Geothermal System Fluids

    SciTech Connect

    Xina Xie; K. K. Bloomfield; G. L. Mines; G. M. Shook

    2005-07-01

    This work evaluates the effect of production well pumping requirements on power generation. The amount of work that can be extracted from a geothermal fluid and the rate at which this work is converted to power increase as the reservoir temperature increases. Artificial lifting is an important issue in this process. The results presented are based on a configuration comprising one production well and one injection well, representing an enhanced geothermal system. The effects of the hydraulic conductivity of the geothermal reservoir, the flow rate, and the size of the production casing are considered in the study. Besides submersible pumps, the possibility of using lineshaft pumps is also discussed.

  14. National Geothermal Data System: Transforming the Discovery, Access, and Analytics of Data for Geothermal Exploration

    SciTech Connect

    Patten, Kim

    2013-05-01

    Compendium of Papers from the 38th Workshop on Geothermal Reservoir Engineering Stanford University, Stanford, California February 11-13, 2013 The National Geothermal Data System (NGDS) is a distributed, interoperable network of data collected from state geological surveys across all fifty states and the nation’s leading academic geothermal centers. The system serves as a platform for sharing consistent, reliable, geothermal-relevant technical data with users of all types, while supplying tools relevant for their work. As aggregated data supports new scientific findings, this content-rich linked data ultimately broadens the pool of knowledge available to promote discovery and development of commercial-scale geothermal energy production. Most of the up-front risks associated with geothermal development stem from exploration and characterization of subsurface resources. Wider access to distributed data will, therefore, result in lower costs for geothermal development. NGDS is on track to become fully operational by 2014 and will provide a platform for custom applications for accessing geothermal relevant data in the U.S. and abroad. It is being built on the U.S. Geoscience Information Network (USGIN) data integration framework to promote interoperability across the Earth sciences community. The basic structure of the NGDS employs state-of-the art informatics to advance geothermal knowledge. The following four papers comprising this Open-File Report are a compendium of presentations, from the 38th Annual Workshop on Geothermal Reservoir Engineering, taking place February 11-13, 2013 at Stanford University, Stanford, California. “NGDS Geothermal Data Domain: Assessment of Geothermal Community Data Needs,” outlines the efforts of a set of nationwide data providers to supply data for the NGDS. In particular, data acquisition, delivery, and methodology are discussed. The paper addresses the various types of data and metadata required and why simple links to existing

  15. Mantle Helium and Carbon Isotopes in Separation Creek Geothermal Springs, Three Sisters Area, Central Oregon: Evidence for Renewed Volcanic Activity or a Long Term Steady State System?

    USGS Publications Warehouse

    Van Soest, M. C.; Kennedy, B.M.; Evans, William C.; Mariner, R.H.

    2002-01-01

    Here we present the helium and carbon isotope results from the initial study of a fluid chemistry-monitoring program started in the summer of 2001 near the South Sister volcano in central Oregon. The Separation Creek area which is several miles due west of the volcano is the locus of strong crustal uplift currently occurring at a rate of 4-5 cm/yr (Wicks, et. al., 2001).Helium [RC/RA = 7.44 and 8.61 RA (RC/R A = (3He/4He)sample-. air corrected/(3He/4He)air))] and carbon (??13C = -11.59 to -9.03??? vs PDB) isotope data and CO2/3He (5 and 9 ?? 109) show that bubbling cold springs in the Separation Creek area near South Sister volcano carry a strong mantle signal, indicating the presence of fresh basaltic magma in the volcanic plumbing system. There is no evidence though, to directly relate this signal to the crustal uplift that is currently taking place in the area, which started in 1998. The geothermal system in the area is apparently much longer lived and shows no significant changes in chemistry compared to data from the early 1990s. Hot springs in the area, which are relatively far removed from the volcanic edifice, do not carry a strong mantle signal in helium isotope ratios (2.79 to 5.08 RA), unlike the cold springs, and also do not show any significant changes in helium isotope ratios compared to literature data for the same springs of over two decades ago. The cold springs of the Separation Creek area form a very diffuse but significant low temperature geothermal system, that should, due to its close vicinity to the center of up uplift, be more sensitive to changes in the deeper volcanic plumbing system than the far removed hot springs and therefore require much more study and consideration when dealing with volcano monitoring in the Cascade range or possibly with geothermal exploration in general.

  16. Monitoring well systems in geothermal areas

    SciTech Connect

    Lofgren, B.E.; O'Rourke, J.; Sterrett, R.; Thackston, J.; Fain, D.

    1982-03-01

    The ability to monitor the injection of spent geothermal fluids at reasonable cost might be greatly improved by use of multiple-completion techniques. Several such techniques, identified through contact with a broad range of experts from the groundwater and petroleum industries, are evaluated relative to application in the typical geologic and hydrologic conditions of the Basin and Range Province of the Western United States. Three basic monitor well designs are suggested for collection of pressure and temperature data: Single standpipe, multiple standpipe, and closed-system piezometers. A fourth design, monitor well/injection well dual completions, is determined to be inadvisable. Also, while it is recognized that water quality data is equally important, designs to allow water sampling greatly increase costs of construction, and so such designs are not included in this review. The single standpipe piezometer is recommended for use at depths less than 152 m (500 ft); several can be clustered in one area to provide information on vertical flow conditions. At depths greater than 152 m (500 ft), the multiple-completion standpipe and closed-system piezometers are likely to be more cost effective. Unique conditions at each monitor well site may necessitate consideration of the single standpipe piezometer even for deeper completions.

  17. National Geothermal Data System: Interactive Assessment of Geothermal Energy Potential in the U.S.

    SciTech Connect

    Allison, Lee; Richard, Stephen; Clark, Ryan; Patten, Kim; Love, Diane; Coleman, Celia; Chen, Genhan; Matti, Jordan; Pape, Estelle; Musil, Leah

    2012-01-30

    Geothermal-relevant geosciences data from all 50 states (www.stategeothermaldata.org), federal agencies, national labs, and academic centers are being digitized and linked in a distributed online network via the U.S. Department of Energy-funded National Geothermal Data System (NGDS) to foster geothermal energy exploration and development through use of interactive online ‘mashups,’data integration, and applications. Emphasis is first to make as much information as possible accessible online, with a long range goal to make data interoperable through standardized services and interchange formats. An initial set of thirty geoscience data content models is in use or under development to define a standardized interchange format: aqueous chemistry, borehole temperature data, direct use feature, drill stem test, earthquake hypocenter, fault feature, geologic contact feature, geologic unit feature, thermal/hot spring description, metadata, quaternary fault, volcanic vent description, well header feature, borehole lithology log, crustal stress, gravity, heat flow/temperature gradient, permeability, and feature descriptions data like developed geothermal systems, geologic unit geothermal properties, permeability, production data, rock alteration description, rock chemistry, and thermal conductivity. Map services are also being developed for isopach maps, aquifer temperature maps, and several states are working on geothermal resource overview maps. Content models are developed preferentially from existing community use in order to encourage widespread adoption and promulgate minimum metadata quality standards. Geoscience data and maps from other NGDS participating institutions, or “nodes” (USGS, Southern Methodist University, Boise State University Geothermal Data Coalition) are being supplemented with extensive land management and land use resources from the Western Regional Partnership (15 federal agencies and 5 Western states) to provide access to a comprehensive

  18. Enhanced Geothermal Systems (EGS) R&D Program

    SciTech Connect

    Entingh, Daniel J.

    1999-08-18

    The purpose of this workshop was to develop technical background facts necessary for planning continued research and development of Enhanced Geothermal Systems (EGS). EGS are geothermal reservoirs that require improvement of their permeability or fluid contents in order to achieve economic energy production. The initial focus of this R&D program is devising and testing means to extract additional economic energy from marginal volumes of hydrothermal reservoirs that are already producing commercial energy. By mid-1999, the evolution of the EGS R&D Program, begun in FY 1988 by the U.S. Department of Energy (DOE), reached the stage where considerable expertise had to be brought to bear on what technical goals should be pursued. The main purpose of this Workshop was to do that. The Workshop was sponsored by the Office of Geothermal Technologies of the Department of Energy. Its purpose and timing were endorsed by the EGS National Coordinating Committee, through which the EGS R&D Program receives guidance from members of the U.S. geothermal industry. Section 1.0 of this report documents the EGS R&D Program Review Session. There, managers and researchers described the goals and activities of the program. Recent experience with injection at The Geysers and analysis of downhole conditions at Dixie Valley highlighted this session. Section 2.0 contains a number of technical presentations that were invited or volunteered to illuminate important technical and economic facts and opportunities for research. The emphasis here was on fi.acture creation, detection, and analysis. Section 3.0 documents the initial general discussions of the participants. Important topics that emerged were: Specificity of defined projects, Optimizing cost effectiveness, Main technical areas to work on, Overlaps between EGS and Reservoir Technology R&D areas, Relationship of microseismic events to hydraulic fractures, and Defining criteria for prioritizing research thrusts. Sections 4.0 and 5.0 report

  19. Technical support for geopressured-geothermal well activities in Louisiana

    SciTech Connect

    Not Available

    1991-07-01

    Continuous recording microearthquake monitoring networks have been established around US Department of Energy (DOE) geopressured-geothermal design wells in southwestern Louisiana and southeastern Texas since summer 1980 to assess the effects well development may have had on subsidence and growth-fault activation. This monitoring has shown several unusual characteristics of Gulf Coast seismic activity. The observed activity is classified into two dominant types, one with identifiable body phases (type 1) and the other with only surface-wave signatures (type 2). During this reporting period no type 1 or body-wave events were reported. A total of 230 type 2 or surface-wave events were recorded. Origins of the type 2 events are still not positively understood; however, little or no evidence is available to connect them with geopressured-geothermal well activity. We continue to suspect sonic booms from military aircraft or some other human-induced source. 37 refs., 16 figs., 6 tabs.

  20. STRUCTURAL CONTROLS OF THE EMERSON PASS GEOTHERMAL SYSTEM, NORTHWESTERN NEVADA: CHARACTERIZATION OF A "BLIND" SYSTEM

    SciTech Connect

    Anderson, Ryan B; Faulds, James E

    2012-12-03

    Detailed geologic analyses have elucidated the kinematics, stress state, structural controls, and past surface activity of a blind geothermal system in Emerson Pass on the Pyramid Lake Paiute Reservation, western Nevada. The Emerson Pass area resides near the boundary of the Basin and Range and Walker Lane provinces and at the western edge of a broad left step or relay ramp between the north- to north-northeast-striking, west-dipping, Fox and Lake Range normal faults. The step-over provides a structurally favorable setting for deep circulation of meteoric fluids. Strata in the area are comprised of late Miocene to Pliocene sedimentary rocks and the middle Miocene Pyramid sequence mafic to intermediate volcanic rocks, all overlying Mesozoic metasedimentary and intrusive rocks. A thermal anomaly was discovered in Emerson Pass by use of 2-m temperature surveys deployed within a structurally favorable setting and proximal to surface features indicative of geothermal activity. The 2-m temperature surveys define a north-south elongate thermal anomaly that has a maximum recorded temperature of ~60°C and resides on a north- to north-northeast-striking normal fault. Although the active geothermal system is expressed solely as a soil heat anomaly, late Pleistocene travertine and tufa mounds, chalcedonic silica/calcite veins, and silica cemented Pleistocene lacustrine gravels indicate a robust geothermal system was active at the surface in the recent past. The geothermal system is controlled primarily by the broad step-over between two major range-bounding normal faults. In detail, the system likely results from enhanced permeability generated by the intersection of two oppositely dipping, southward terminating north- to north-northwest-striking (Fox Range fault) and north-northeast-striking normal faults. Structural complexity and spatial heterogeneities of the strain and stress field have developed in the step-over region, but kinematic data suggest a west

  1. Feasibility and Supply Analysis of U.S. Geothermal District Heating and Cooling System

    NASA Astrophysics Data System (ADS)

    He, Xiaoning

    Geothermal energy is a globally distributed sustainable energy with the advantages of a stable base load energy production with a high capacity factor and zero SOx, CO, and particulates emissions. It can provide a potential solution to the depletion of fossil fuels and air pollution problems. The geothermal district heating and cooling system is one of the most common applications of geothermal energy, and consists of geothermal wells to provide hot water from a fractured geothermal reservoir, a surface energy distribution system for hot water transmission, and heating/cooling facilities to provide water and space heating as well as air conditioning for residential and commercial buildings. To gain wider recognition for the geothermal district heating and cooling (GDHC) system, the potential to develop such a system was evaluated in the western United States, and in the state of West Virginia. The geothermal resources were categorized into identified hydrothermal resources, undiscovered hydrothermal resources, near hydrothermal enhanced geothermal system (EGS), and deep EGS. Reservoir characteristics of the first three categories were estimated individually, and their thermal potential calculated. A cost model for such a system was developed for technical performance and economic analysis at each geothermally active location. A supply curve for the system was then developed, establishing the quantity and the cost of potential geothermal energy which can be used for the GDHC system. A West Virginia University (WVU) case study was performed to compare the competiveness of a geothermal energy system to the current steam based system. An Aspen Plus model was created to simulate the year-round campus heating and cooling scenario. Five cases of varying water flow rates and temperatures were simulated to find the lowest levelized cost of heat (LCOH) for the WVU case study. The model was then used to derive a levelized cost of heat as a function of the population density

  2. The Newcastle geothermal system, Iron County, Utah

    SciTech Connect

    Blackett, R.E.; Shubat, M.A.; Bishop, C.E. ); Chapman, D.S.; Forster, C.B.; Schlinger, C.M. . Dept. of Geology and Geophysics)

    1990-03-01

    Geological, geophysical and geochemical studies contributed to conceptual hydrologic model of the blind'' (no surface expression), moderate-temperature (greater than 130{degree}C) Newcastle geothermal system, located in the Basin and Range-Colorado Plateau transition zone of southwestern Utah. Temperature gradient measurements define a thermal anomaly centered near the surface trace of the range-bounding Antelope Range fault with and elongate dissipative plume extending north into the adjacent Escalante Valley. Spontaneous potential and resistivity surveys sharply define the geometry of the dominant upflow zone (not yet explored), indicating that most of the thermal fluid issues form a short segment along the Antelope Range fault and discharges into a gently-dipping aquifer. Production wells show that this aquifer lies at a depth between 85 and 95 meter. Electrical surveys also show that some leakage of thermal fluid occurs over a 1.5 km (minimum) interval along the trace of the Antelope Range fault. Major element, oxygen and hydrogen isotopic analyses of water samples indicate that the thermal fluid is a mixture of meteoric water derived from recharge areas in the Pine Valley Mountains and cold, shallow groundwater. A northwest-southeast trending system of faults, encompassing a zone of increased fracture permeability, collects meteoric water from the recharge area, allows circulation to a depth of 3 to 5 kilometers, and intersects the northeast-striking Antelope Range fault. We postulate that mineral precipitates form a seal along the Antelope Range fault, preventing the discharge of thermal fluids into basin-fill sediments at depth, and allowing heated fluid to approach the surface. Eventually, continued mineral deposition could result in the development of hot springs at the ground surface.

  3. Geothermal systems on the island of Bali, Indonesia

    NASA Astrophysics Data System (ADS)

    Purnomo, Budi Joko; Pichler, Thomas

    2015-10-01

    This paper presents an overview of the geothermal systems on the island of Bali, Indonesia. Physicochemical data of hot springs and shallow geothermal wells were collected from four geothermal locations: Penebel, Batur, Banjar and Banyuwedang. The concentrations for the three main anions varied significantly indicating a different geothermal history. The values for Cl- ranged from 0.1 to 1000 mg/L, for HCO3- from 20 to 2200 mg/L and for SO42 - from 0.1 to 500 mg/L. Although the island of Bali is underlain by carbonate rocks, a carbonate host rock for the geothermal reservoirs could not be confirmed, because the (Ca2 + + Mg2 +)/HCO3- molar ratios were approximately 0.4, well below 1.0 and the K/Mg ratios were approaching those of a calc-alkaline rock reservoir. The HCO3- of the thermal waters correlated with Ca2 +, Mg2 +, Sr2 + and K+ indicating water-rock interaction in the presence of carbonic acid. Phase separation was inferred for the Bedugul and Banjar geothermal systems, because of relatively high B/Cl ratios. Boron isotopes were determined for selected samples with values ranging from δ11B of 1.3 to 22.5‰ (NBS 951). The heavy δ11B of + 22.5‰ together with a low B/Cl ratio indicated seawater input in the Banyuwedang geothermal system. The hydrogen and oxygen isotopic composition of the thermal water plotted along the global meteoric water line (GMWL) and close to the mean annual value for precipitation in Jakarta indicating a meteoric origin of the geothermal water. Comparison of the Si, Na/K, Na/K/Ca and Na/Li geothermometers with actual reservoir temperature measurements and physicochemical considerations led to the conclusion that the Na/Li thermometer provided most reliable results for the determination of geothermal reservoir temperatures on Bali. Using this thermometer, the following reservoir temperatures were calculated: (1) Penebel (Bedugul) from 235 to 254 °C, (2) Batur 240 °C and (3) Banjar 255 °C. Due to seawater input this thermometer

  4. Seismic Activity at tres Virgenes Volcanic and Geothermal Field

    NASA Astrophysics Data System (ADS)

    Antayhua, Y. T.; Lermo, J.; Quintanar, L.; Campos-Enriquez, J. O.

    2013-05-01

    The volcanic and geothermal field Tres Virgenes is in the NE portion of Baja California Sur State, Mexico, between -112°20'and -112°40' longitudes, and 27°25' to 27°36' latitudes. Since 2003 Power Federal Commission and the Engineering Institute of the National Autonomous University of Mexico (UNAM) initiated a seismic monitoring program. The seismograph network installed inside and around the geothermal field consisted, at the beginning, of Kinemetrics K2 accelerometers; since 2009 the network is composed by Guralp CMG-6TD broadband seismometers. The seismic data used in this study covered the period from September 2003 - November 2011. We relocated 118 earthquakes with epicenter in the zone of study recorded in most of the seismic stations. The events analysed have shallow depths (≤10 km), coda Magnitude Mc≤2.4, with epicentral and hypocentral location errors <2 km. These events concentrated mainly below Tres Virgenes volcanoes, and the geothermal explotation zone where there is a system NW-SE, N-S and W-E of extensional faults. Also we obtained focal mechanisms for 38 events using the Focmec, Hash, and FPFIT methods. The results show normal mechanisms which correlate with La Virgen, El Azufre, El Cimarron and Bonfil fault systems, whereas inverse and strike-slip solutions correlate with Las Viboras fault. Additionally, the Qc value was obtained for 118 events. This value was calculated using the Single Back Scattering model, taking the coda-waves train with window lengths of 5 sec. Seismograms were filtered at 4 frequency bands centered at 2, 4, 8 and 16 Hz respectively. The estimates of Qc vary from 62 at 2 Hz, up to 220 at 16 Hz. The frequency-Qc relationship obtained is Qc=40±2f(0.62±0.02), representing the average attenuation characteristics of seismic waves at Tres Virgenes volcanic and geothermal field. This value correlated with those observed at other geothermal and volcanic fields.

  5. Occurence of ore metals in some terrestrial geothermal systems

    SciTech Connect

    Browne, P.

    1984-02-01

    Drilling programs and the study of active geothermal systems have shown that the reservoir rocks in many fields contain minor quantities of base and precious metals. Commonly, base-metal sulfides occur in the subsurface but, where present, Au, Ag, Hg, As, Tl and Sb rich precipitates deposit near, or at, the surface. Although in some fields (Geysers, Larderello, Tongonan) some of the ore minerals (and others) are relict, there is evidence that they are now depositing in a few systems. Recent work on active hydrothermal systems in New Zealand shows that: (1) Sphalerite, galena, chalcopyrite (forming veins and disseminated discrete crystals) plus rare pentlandite, cobaltite and arsenopyrite, occur at Broadlands, NZ. Rare quantities of base-metal sulfides also occur in cores and cuttings from the geothermal fields of Waiotapu, Kawerau, Tauhara, and Ngawha. Further, Kakimoto (1983) has identified cassiterite, native silver, and trace gold in cores from Tauhara, in the south-eastern part of the Wairakei field. Bore temperatures at the depths from which these minerals were recovered are mostly between 220/sup 0/ and 300/sup 0/C, but at Broadlands are locally as low as 120/sup 0/C. The host rocks are Quaternary calc-alkali, silicic lavas and pyroclastic rocks, andesites, dacite and deep Mesozoic greywackes and argillites; however, there is no obvious relationship between mineralization and stratigraphy, permeability or well output. The deposition of amorphous precious metal precipitates (Au, Ag, Hg, As, Sb, Tl) from hot springs and well discharges has taken place at Broadlands, Waiotapu and Rotokawa; it also occurs at Kawerau. Water discharging from Frying Pan Lake, Waimangu, is presently depositing siliceous sinter containing up to 4.1% tungsten.

  6. [Geothermal system temperature-depth database and model for data analysis]. 5. quarterly technical progress report

    SciTech Connect

    Blackwell, D.D.

    1998-04-25

    During this first quarter of the second year of the contract activity has involved several different tasks. The author has continued to work on three tasks most intensively during this quarter: the task of implementing the data base for geothermal system temperature-depth, the maintenance of the WWW site with the heat flow and gradient data base, and finally the development of a modeling capability for analysis of the geothermal system exploration data. The author has completed the task of developing a data base template for geothermal system temperature-depth data that can be used in conjunction with the regional data base that he had already developed and is now implementing it. Progress is described.

  7. Geothermal direct applications hardware systems development and testing. 1979 summary report

    SciTech Connect

    Keller, J.G.

    1980-03-01

    Activities performed during calendar year 1979 for the hardware system development and testing task are presented. The fluidized bed technology was applied to the drying of potato by-products and to the exchange of heat to air in the space heating experiment. Geothermal water was flashed to steam and also used as the prime energy source in the steam distillation of peppermint oil. Geothermal water temperatures as low as 112.8/sup 0/C were utilized to distill alcohol from sugar beet juice, and lower temperature water provided air conditioning through an absorption air conditioning system. These experiments are discussed.

  8. Changes in thermal activity in the Rotorua geothermal field

    SciTech Connect

    Cody, A.D. ); Lumb, J.T. )

    1992-04-01

    During a period when geothermal fluid was being withdrawn for energy use at an increasing rate, the level of natural hydrothermal activity in the Rotorua geothermal field declined in an all-time low in the mid 1980s. total heatflow from a major hot-spring area fell by almost 50 percent, springs ceased their flow, and geysers displayed abnormal behavior consistent with a low aquifer pressure. since the enforced closure of bores within 1.5 km of Pohutu Geyser, sings of recovery, including a return to normal behavior of Pohutu and Waikorohihi Geysers, a resumption of activity at Kereru Geyser, and an increase in water flow from some springs are presented in this paper.

  9. Investigation of a fossil geothermal system, Hamblin-Cleopatra Volcano, Clark County, Nevada. Final technical report

    SciTech Connect

    Barker, D.S.

    1986-07-28

    The Hamblin-Cleopatra volcano, selected for study because erosion and fault displacement have exposed the entire volcanic succession, the intrusive core, a radial dike systems, and sedimentary and volcanic rocks that predate and postdate the volcano, was investigated to estimate the proportions of igneous materials forming lava flows, pyroclastic deposits, intrusive bodies, and reworked debris. Chemical changes in the magma throughout the active period of the volcano were documented. The geothermal system active within the pile after activity ceased was reconstructed. (ACR)

  10. Three dimensional images of geothermal systems: local earthquake P-wave velocity tomography at the Hengill and Krafla geothermal areas, Iceland, and The Geysers, California

    USGS Publications Warehouse

    Julian, B.R.; Prisk, A.; Foulger, G.R.; Evans, J.R.; ,

    1993-01-01

    Local earthquake tomography - the use of earthquake signals to form a 3-dimensional structural image - is now a mature geophysical analysis method, particularly suited to the study of geothermal reservoirs, which are often seismically active and severely laterally inhomogeneous. Studies have been conducted of the Hengill (Iceland), Krafla (Iceland) and The Geysers (California) geothermal areas. All three systems are exploited for electricity and/or heat production, and all are highly seismically active. Tomographic studies of volumes a few km in dimension were conducted for each area using the method of Thurber (1983).

  11. Variation in sericite composition from fracture zones within the Coso Hot Sprints geothermal system

    SciTech Connect

    Bishop, B.P.; Bird, D.K.

    1987-05-01

    Two types of white micas are found in drill hole samples within the geothermal system at Coso Hot Springs. Low-permeability zones of the crystalline basement contain coarse-grained relict muscovite, whereas rock alteration near fracture zones at temperatures > 150/sup 0/C is characterized by abundant fine-grained sericite in association with secondary calcite and quartz and unaltered relict microcline. In this hydrothermal sericite there is an increase in interlayer K, octahedral Mg + Fe/sub total/ and tetrahedral Al with increasing temperature between approx. 215/sup 0/ to >250/sup 0/C. Thermodynamic activity of the Al/sub 2/Si/sub 4/O/sub 10/(OH)/sub 2/ component of sericites, calculated using site-mixing approximations of HELGESON and AAGAARD (1985), decreases with increasing temperature between approx. 215/sup 0/ and >250/sup 0/C. Although the compositions of hydrothermal sericites are a complex function of temperature, pressure and geothermal fluid composition, compositional relations observed at Coso together with published compositions of hydrothermal dioctahedral layer-silicates from the Salton Sea geothermal system demonstrates that elemental compositions of interlayer K and tetrahedral Al increase systematically with increasing temperature despite the dramatic differences in fluid compositions between these two geothermal systems. This suggests that the observed variations in interlayer and tetrahedral site occupancy is largely dependent on the enthalpy of hydrolysis reactions representing equilibrium between sericite solid solutions and the geothermal reservoir fluids.

  12. Structural Controls of the Geothermal System at Gerlach, Washoe County, Nevada

    NASA Astrophysics Data System (ADS)

    Hazelwood, Lyndsay A.

    Detailed geologic mapping, spring and two-meter temperature data, and gravity and magnetic data constrain the structural controls of the high-temperature (>175°C) geothermal system at Gerlach. The system lies along the termination of a major normal fault at the southern end of the Granite Range in the southern Black Rock Desert, a known favorable setting for geothermal activity. Mapping of Quaternary deposits documents Holocene movement on the north-northeast-striking, east-dipping Gerlach fault. Dominant orientations of geothermal veins in exposed fossil geothermal systems parallel this active, terminating range-front fault, suggesting that it does provide a major control on the current geothermal system. Locally, there are two areas of geothermal upwelling with separate sets of structural controls. The two areas are expressed by outflow as two sets of springs, Great Boiling Springs and Mud Springs, as well as by separate altered bedrock fossil systems above the springs. The areas are topographically distinct (neither could represent outflow from the other), are separated by relatively lower shallow temperature measurements, and are associated with different orientations of the gravity gradient. Prominent northwest-striking fractures provide areas of enhanced permeability and parallel the secondary set of veins in the altered bedrock uphill of Great Boiling Springs. These northwest-striking veins are not observed in the area above Mud Springs, but there is an east-northeast-striking set that is not present above Great Boiling Springs. The presence of east-northeast-striking structures is supported in the gravity data. These structures could represent an ever broader-scale structural connection between the southern termination of the Gerlach fault and the northern termination of the Fox Range fault to the south.

  13. Recommendations of the workshop on advanced geothermal drilling systems

    SciTech Connect

    Glowka, D.A.

    1997-12-01

    At the request of the U.S. Department of Energy, Office of Geothermal Technologies, Sandia National Laboratories convened a group of drilling experts in Berkeley, CA, on April 15-16, 1997, to discuss advanced geothermal drilling systems. The objective of the workshop was to develop one or more conceptual designs for an advanced geothermal drilling system that meets all of the criteria necessary to drill a model geothermal well. The drilling process was divided into ten essential functions. Each function was examined, and discussions were held on the conventional methods used to accomplish each function and the problems commonly encountered. Alternative methods of performing each function were then listed and evaluated by the group. Alternative methods considered feasible or at least worth further investigation were identified, while methods considered impractical or not potentially cost-saving were eliminated from further discussion. This report summarizes the recommendations of the workshop participants. For each of the ten functions, the conventional methods, common problems, and recommended alternative technologies and methods are listed. Each recommended alternative is discussed, and a description is given of the process by which this information will be used by the U.S. DOE to develop an advanced geothermal drilling research program.

  14. A market survey of geothermal wellhead power generation systems

    NASA Technical Reports Server (NTRS)

    Leeds, M. W.

    1978-01-01

    The market potential for a portable geothermal wellhead power conversion device is assessed. Major study objectives included identifying the most promising applications for such a system, the potential impediments confronting their industrialization, and the various government actions needed to overcome these impediments. The heart of the study was a series of structured interviews with key decision-making individual in the various disciplines of the geothermal community. In addition, some technical and economic analyses of a candidate system were performed to support the feasibility of the basic concept.

  15. Documentation of the status of international geothermal power plants and a list by country of selected geothermally active governmental and private sector entities

    SciTech Connect

    Not Available

    1992-10-01

    This report includes the printouts from the International Geothermal Power Plant Data Base and the Geothermally Active Entity Data Base. Also included are the explanation of the abbreviations used in the power plant data base, maps of geothermal installations by country, and data base questionnaires and mailing lists.

  16. Mathematical modeling of the behavior of geothermal systems under exploitation

    SciTech Connect

    Bodvarsson, G.S.

    1982-01-01

    Analytical and numerical methods have been used in this investigation to model the behavior of geothermal systems under exploitation. The work is divided into three parts: (1) development of a numerical code, (2) theoretical studies of geothermal systems, and (3) field applications. A new single-phase three-dimensional simulator, capable of solving heat and mass flow problems in a saturated, heterogeneous porous or fractured medium has been developed. The simulator uses the integrated finite difference method for formulating the governing equations and an efficient sparse solver for the solution of the linearized equations. In the theoretical studies, various reservoir engineering problems have been examined. These include (a) well-test analysis, (b) exploitation strategies, (c) injection into fractured rocks, and (d) fault-charged geothermal reservoirs.

  17. Structural compartmentalisation of a geothermal system, the Torre Alfina field (central Italy)

    NASA Astrophysics Data System (ADS)

    Vignaroli, Gianluca; Pinton, Annamaria; De Benedetti, Arnaldo A.; Giordano, Guido; Rossetti, Federico; Soligo, Michele; Berardi, Gabriele

    2013-11-01

    Recent surging of renewed industrial interest in the exploration of low and medium enthalpy geothermal fields makes the accurate assessment of the geothermal potential essential to minimise uncertainties during both exploration and exploitation. The Torre Alfina field is a case of abandoned, but promising, geothermal field of central Italy where the roles of the internal structural setting and of the recharge areas on the hydrothermal circulation are largely unconstrained. In this paper, field structural data integrated with geomorphic lineament analysis document the occurrence of post-orogenic deformation structures controlling the compartmentalisation of the Torre Alfina geothermal field. Strike-slip and subordinate normal fault systems (with associated network fractures) cut and dislocate the internal architecture of the reservoir and prevent its hydraulic connection with Mount Cetona, considered to be the recharge area and where hydrothermal manifestation, including travertine deposition, occurs. 230Th/234U radiometric dating of superposed travertine units gives 200, 120 and 90 ka respectively, inferred to correspond to the age of the fossil hydrothermal circulation during tectonic activity. The results have been used for illustrating a new geological conceptual model for the Torre Alfina area where the geothermal system is composed of different compartments. Tectonic structures define the main boundaries between compartments, helping the understanding of why productive and non-productive wells were found in apparently similar structural settings within the Torre Alfina field.

  18. Enhanced Geothermal Systems: Mitigating Risk in Urban Areas

    NASA Astrophysics Data System (ADS)

    Kraft, Toni; Mai, Paul Martin; Wiemer, Stefan; Deichmann, Nicholas; Ripperger, Johannes; Kästli, Philipp; Bachmann, Corinne; Fäh, Donat; Wössner, Jochen; Giardini, Domenico

    2009-08-01

    With the global challenge to satisfy an increasing demand for energy while at the same time stabilizing or reducing carbon dioxide (CO2) concentrations in the atmosphere, geothermal energy from enhanced geothermal systems (EGSs) increasingly is being recognized as an attractive alternative energy source throughout the world. However, the risks associated with the seismicity necessarily induced during the development of an EGS constitute a significant challenge for the widespread implementation of this technology. This article provides a preliminary overview of lessons learned from an attempt to develop an EGS beneath the city of Basel, Switzerland.

  19. Three-Dimensional Geologic Characterization of a Great Basin Geothermal System: Astor Pass, Nevada

    SciTech Connect

    Mayhew, Brett; Siler, Drew L; Faulds, James E

    2013-09-30

    The Great Basin, western USA, exhibits anomalously high heat flow (~75±5 mWm-2) and active faulting and extension, resulting in ~430 known geothermal systems. Recent studies have shown that steeply dipping normal faults in transtensional pull-aparts are a common structural control of these Great Basin geothermal systems. The Astor Pass blind (no surface expression) geothermal system, Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Across this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range, resulting in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and northerly striking normal faults. Previous studies indicate that Astor Pass was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal-dextral fault bounding the western side of the Terraced Hills. Drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming a blind geothermal system. Expanding upon previous work and employing interpretation of 2D seismic reflection data, additional detailed geologic mapping, and well cuttings analysis, a 3-dimensional geologic model of the Astor Pass geothermal system was constructed. The 3D model indicates a complex interaction/intersection area of three discrete fault zones: a northwest-striking dextral-normal fault, a north-northwest-striking normal-dextral fault, and a north-striking west-dipping normal fault. These two discrete, critically-stressed intersection areas plunge moderately to steeply to the NW-NNW and probably act as conduits for upwelling geothermal fluids.

  20. 3D characterization of the Astor Pass geothermal system, Nevada

    SciTech Connect

    Mayhew, Brett; Faulds, James E

    2013-10-19

    The Astor Pass geothermal system resides in the northwestern part of the Pyramid Lake Paiute Reservation, on the margins of the Basin and Range and Walker Lane tectonic provinces in northwestern Nevada. Seismic reflection interpretation, detailed analysis of well cuttings, stress field analysis, and construction of a 3D geologic model have been used in the characterization of the stratigraphic and structural framework of the geothermal area. The area is primarily comprised of middle Miocene Pyramid sequence volcanic and sedimentary rocks, nonconformably overlying Mesozoic metamorphic and granitic rocks. Wells drilled at Astor Pass show a ~1 km thick section of highly transmissive Miocene volcanic reservoir with temperatures of ~95°C. Seismic reflection interpretation confirms a high fault density in the geothermal area, with many possible fluid pathways penetrating into the relatively impermeable Mesozoic basement. Stress field analysis using borehole breakout data reveals a complex transtensional faulting regime with a regionally consistent west-northwest-trending least principal stress direction. Considering possible strike-slip and normal stress regimes, the stress data were utilized in a slip and dilation tendency analysis of the fault model, which suggests two promising fault areas controlling upwelling geothermal fluids. Both of these fault intersection areas show positive attributes for controlling geothermal fluids, but hydrologic tests show the ~1 km thick volcanic section is highly transmissive. Thus, focused upwellings along discrete fault conduits may be confined to the Mesozoic basement before fluids diffuse into the Miocene volcanic reservoir above. This large diffuse reservoir in the faulted Miocene volcanic rocks is capable of sustaining high pump rates. Understanding this type of system may be helpful in examining large, permeable reservoirs in deep sedimentary basins of the eastern Basin and Range and the highly fractured volcanic geothermal

  1. Description and operation of Haakon School geothermal-heating system

    SciTech Connect

    Childs, F.W.; Kirol, L.D.; Sanders, R.D.; McLatchy, M.J.

    1983-10-01

    To encourage the development of hydrothermal energy, twenty-three demonstration projects were funded. The Haakon School project is one of twelve such projects. The geothermal direct-use heating system at the Haakon School complex in Philip, South Dakota is described and information gained during approximately three heating seasons of operation is presented.

  2. Early Devonian geothermal systems in northeast Scotland: Exploration targets for epithermal gold

    SciTech Connect

    Nicholson, K. )

    1989-06-01

    Early Devonian geothermal activity is recognized in northeast Scotland by the remnants of silica sinter, a hot-spring manganese deposit, an area of steam alteration, and hydrothermal eruption breccias. At least five systems were active at this time, three of which are located on or near the intersection of major faults and lineaments. Two deposits can be dated as Early Devonian, whereas others show a spatial relation to 408 Ma Caledonian granitoids-the proposed heat sources for the geothermal systems. Fault zones active at this time provided channelways for fluids in the convecting systems. The shallow sections of these systems have been preserved in the Arndilly, Dalroy, Lecht, and Rhynie areas, which is encouraging for gold prospecting. Six targets for epithermal gold exploration are identified: the four areas named above and two areas at the intersection of major faults and lineaments.

  3. Tectonic and Structural Controls of Geothermal Activity in the Great Basin Region, Western USA

    NASA Astrophysics Data System (ADS)

    Faulds, J. E.; Hinz, N.; Kreemer, C. W.

    2012-12-01

    We are conducting a thorough inventory of structural settings of geothermal systems (>400 total) in the extensional to transtensional Great Basin region of the western USA. Most of the geothermal systems in this region are not related to upper crustal magmatism and thus regional tectonic and local structural controls are the most critical factors controlling the locations of the geothermal activity. A system of NW-striking dextral faults known as the Walker Lane accommodates ~20% of the North American-Pacific plate motion in the western Great Basin and is intimately linked to N- to NNE-striking normal fault systems throughout the region. Overall, geothermal systems are concentrated in areas with the highest strain rates within or proximal to the eastern and western margins of the Great Basin, with the high temperature systems clustering in transtensional areas of highest strain rate in the northwestern Great Basin. Enhanced extension in the northwestern Great Basin probably results from the northwestward termination of the Walker Lane and the concomitant transfer of dextral shear into west-northwest directed extension, thus producing a broad transtensional region. The capacity of geothermal power plants also correlates with strain rates, with the largest (hundreds of megawatts) along the Walker Lane or San Andreas fault system, where strain rates range from 10-100 nanostrain/yr to 1,000 nanostrain/yr, respectively. Lesser systems (tens of megawatts) reside in the Basin and Range (outside the Walker Lane), where local strain rates are typically < 10 nanostrain/yr. Of the 250+ geothermal fields catalogued, step-overs or relay ramps in normal fault zones serve as the most favorable setting, hosting ~32% of the systems. Such areas have multiple, overlapping fault strands, increased fracture density, and thus enhanced permeability. Other common settings include a) intersections between normal faults and strike-slip or oblique-slip faults (27%), where multiple minor

  4. COTHERM: Geophysical Modeling of High Enthalpy Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Grab, Melchior; Maurer, Hansruedi; Greenhalgh, Stewart

    2014-05-01

    In recent years geothermal heating and electricity generation have become an attractive alternative energy resource, especially natural high enthalpy geothermal systems such as in Iceland. However, the financial risk of installing and operating geothermal power plants is still high and more needs to be known about the geothermal processes and state of the reservoir in the subsurface. A powerful tool for probing the underground system structure is provided by geophysical techniques, which are able to detect flow paths and fracture systems without drilling. It has been amply demonstrated that small-scale features can be well imaged at shallow depths, but only gross structures can be delineated for depths of several kilometers, where most high enthalpy systems are located. Therefore a major goal of our study is to improve geophysical mapping strategies by multi-method geophysical simulations and synthetic data inversions, to better resolve structures at greater depth, characterize the reservoir and monitor any changes within it. The investigation forms part of project COTHERM - COmbined hydrological, geochemical and geophysical modeling of geoTHERMal systems - in which a holistic and synergistic approach is being adopted to achieve multidisciplinary cooperation and mutual benefit. The geophysical simulations are being performed in combination with hydrothermal fluid flow modeling and chemical fluid rock interaction modeling, to provide realistic constraints on lithology, pressure, temperature and fluid conditions of the subsurface. Two sites in Iceland have been selected for the study, Krafla and Reykjanes. As a starting point for the geophysical modeling, we seek to establish petrophysical relations, connecting rock properties and reservoir conditions with geophysical parameters such as seismic wave speed, attenuation, electrical conductivity and magnetic susceptibility with a main focus on seismic properties. Therefore, we follow a comprehensive approach involving

  5. Structural Controls of the Emerson Pass Geothermal System, Washoe County, Nevada

    SciTech Connect

    Anderson, Ryan B; Faulds, James E

    2012-09-30

    We have conducted a detailed geologic study to better characterize a blind geothermal system in Emerson Pass on the Pyramid Lake Paiute Tribe Reservation, western Nevada. A thermal anomaly was discovered in Emerson Pass by use of 2 m temperature surveys deployed within a structurally favorable setting and proximal to surface features indicative of geothermal activity. The anomaly lies at the western edge of a broad left step at the northeast end of Pyramid Lake between the north- to north-northeast-striking, west-dipping, Fox and Lake Range normal faults. The 2-m temperature surveys have defined a N-S elongate thermal anomaly that has a maximum recorded temperature of ~60°C and resides on a north- to north-northeaststriking fault. Travertine mounds, chalcedonic silica veins, and silica cemented Pleistocene lacustrine gravels in Emerson Pass indicate a robust geothermal system active at the surface in the recent past. Structural complexity and spatial heterogeneities of the strain and stress field have developed in the step-over region, but kinematic data suggest a WNW-trending (~280° azimuth) extension direction. The geothermal system is likely hosted in Emerson Pass as a result of enhanced permeability generated by the intersection of two oppositely dipping, southward terminating north- to north-northwest-striking (Fox Range fault) and northnortheast- striking faults.

  6. Energy Return On Investment of Engineered Geothermal Systems Data

    DOE Data Explorer

    Mansure, Chip

    2012-01-01

    The project provides an updated Energy Return on Investment (EROI) for Enhanced Geothermal Systems (EGS). Results incorporate Argonne National Laboratory's Life Cycle Assessment and base case assumptions consistent with other projects in the Analysis subprogram. EROI is a ratio of the energy delivered to the consumer to the energy consumed to build, operate, and decommission the facility. EROI is important in assessing the viability of energy alternatives. Currently EROI analyses of geothermal energy are either out-of-date, of uncertain methodology, or presented online with little supporting documentation. This data set is a collection of files documenting data used to calculate the Energy Return On Investment (EROI) of Engineered Geothermal Systems (EGS) and erratum to publications prior to the final report. Final report is available from the OSTI web site (http://www.osti.gov/geothermal/). Data in this collections includes the well designs used, input parameters for GETEM, a discussion of the energy needed to haul materials to the drill site, the baseline mud program, and a summary of the energy needed to drill each of the well designs. EROI is the ratio of the energy delivered to the customer to the energy consumed to construct, operate, and decommission the facility. Whereas efficiency is the ratio of the energy delivered to the customer to the energy extracted from the reservoir.

  7. Modeling Studies of Geothermal Systems with a Free Water Surface

    SciTech Connect

    Bodvarsson, Gudmundur S.; Pruess, K.

    1983-12-15

    Numerical simulators developed for geothermal reservoir engineering applications generally only consider systems which are saturated with liquid water and/or steam. However, most geothermal fields are in hydraulic communicatino with shallow ground water aquifers having free surface (water level), so that production or injection operations will cause movement of the surface, and of the air in the pore spaces above the water level. In some geothermal fields the water level is located hundreds of meters below the surface (e.g. Olkaria, Kenya; Bjornsson, 1978), so that an extensive so that an extensive unsaturated zone is present. In other the caprock may be very leaky or nonexistent [e.g., Klamath Falls, oregon (Sammel, 1976)]; Cerro Prieto, Mexico; (Grant et al., 1984) in which case ther eis good hydraulic communication between the geothermal reservoir and the shallow unconfined aquifers. Thus, there is a need to explore the effect of shallow free-surface aquifers on reservoir behavior during production or injection operations. In a free-surface aquifer the water table moves depending upon the rate of recharge or discharge. This results in a high overall storativity; typically two orders of magnitude higher than that of compressed liquid systems, but one or two orders of magnitude lower than that for liquid-steam reservoirs. As a consequence, various data analysis methods developed for compressed liquid aquifers (such as conventional well test analysis methods) are not applicable to aquifer with a free surface.

  8. Structural Orientations Adjacent to Some Colorado Geothermal Systems

    SciTech Connect

    Richard,

    2012-02-01

    Citation Information: Originator: Geothermal Development Associates, Reno, Nevada Publication Date: 2012 Title: Structural Data Edition: First Publication Information: Publication Place: Reno Nevada Publisher: Geothermal Development Associates, Reno, Nevada Description: Structural orientations (fractures, joints, faults, lineaments, bedding orientations, etc.) were collected with a standard Brunton compass during routine field examinations of geothermal phenomena in Colorado. Often multiple orientations were taken from one outcrop. Care was taken to ensure outcrops were "in place". Point data was collected with a hand-held GPS unit. The structural data is presented both as standard quadrant measurements and in format suitable for ESRI symbology Spatial Domain: Extent: Top: 4491528.924999 m Left: 207137.983196 m Right: 432462.310324 m Bottom: 4117211.772001 m Contact Information: Contact Organization: Geothermal Development Associates, Reno, Nevada Contact Person: Richard “Rick” Zehner Address: 3740 Barron Way City: Reno State: NV Postal Code: 89511 Country: USA Contact Telephone: 775-737-7806 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System 1984 (WGS ’1984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

  9. Multiparameter fiber optic sensing system for monitoring enhanced geothermal systems

    SciTech Connect

    Challener, William A

    2014-12-04

    The goal of this project was to design, fabricate and test an optical fiber cable which supports multiple sensing modalities for measurements in the harsh environment of enhanced geothermal systems. To accomplish this task, optical fiber was tested at both high temperatures and strains for mechanical integrity, and in the presence of hydrogen for resistance to darkening. Both single mode (SM) and multimode (MM) commercially available optical fiber were identified and selected for the cable based on the results of these tests. The cable was designed and fabricated using a tube-within-tube construction containing two MM fibers and one SM fiber, and without supporting gel that is not suitable for high temperature environments. Commercial fiber optic sensing instruments using Raman DTS (distributed temperature sensing), Brillouin DTSS (distributed temperature and strain sensing), and Raleigh COTDR (coherent optical time domain reflectometry) were selected for field testing. A microelectromechanical systems (MEMS) pressure sensor was designed, fabricated, packaged, and calibrated for high pressure measurements at high temperatures and spliced to the cable. A fiber Bragg grating (FBG) temperature sensor was also spliced to the cable. A geothermal well was selected and its temperature and pressure were logged. The cable was then deployed in the well in two separate field tests and measurements were made on these different sensing modalities. Raman DTS measurements were found to be accurate to ±5°C, even with some residual hydrogen darkening. Brillouin DTSS measurements were in good agreement with the Raman results. The Rayleigh COTDR instrument was able to detect some acoustic signatures, but was generally disappointing. The FBG sensor was used to determine the effects of hydrogen darkening, but drift over time made it unreliable as a temperature or pressure sensor. The MEMS sensor was found to be highly stable and accurate to better than its 0.1% calibration.

  10. Numerical modeling of geothermal systems with applications to Krafla, Iceland and Olkaria, Kenya

    SciTech Connect

    Bodvarsson, G.S.

    1987-08-01

    The use of numerical models for the evaluation of the generating potential of high temperature geothermal fields has increased rapidly in recent years. In the present paper a unified numerical approach to the modeling of geothermal systems is discussed and the results of recent modeling of the Krafla geothermal field in Iceland and the Olkaria, Kenya, are described. Emphasis is placed on describing the methodology using examples from the two geothermal fields.

  11. COTHERM: Modelling fluid-rock interactions in Icelandic geothermal systems

    NASA Astrophysics Data System (ADS)

    Thien, Bruno; Kosakowski, Georg; Kulik, Dmitrii

    2014-05-01

    Mineralogical alteration of reservoir rocks, driven by fluid circulation in natural or enhanced geothermal systems, is likely to influence the long-term performance of geothermal power generation. A key factor is the change of porosity due to dissolution of primary minerals and precipitation of secondary phases. Porosity changes will affect fluid circulation and solute transport, which, in turn, influence mineralogical alteration. This study is part of the Sinergia COTHERM project (COmbined hydrological, geochemical and geophysical modeling of geotTHERMal systems) that is an integrative research project aimed at improving our understanding of the sub-surface processes in magmatically-driven natural geothermal systems. We model the mineralogical and porosity evolution of Icelandic geothermal systems with 1D and 2D reactive transport models. These geothermal systems are typically high enthalphy systems where a magmatic pluton is located at a few kilometers depth. The shallow plutons increase the geothermal gradient and trigger the circulation of hydrothermal waters with a steam cap forming at shallow depth. We investigate two contrasting geothermal systems: Krafla, for which the water recharge consists of meteoritic water; and Reykjanes, for which the water recharge mainly consists of seawater. The initial rock composition is a fresh basalt. We use the GEM-Selektor geochemical modeling package [1] for calculation of kinetically controlled mineral equilibria between the rock and the ingression water. We consider basalt minerals dissolution kinetics according to Palandri & Kharaka [2]. Reactive surface areas are assumed to be geometric surface areas, and are corrected using a spherical-particle surface/mass relationship. For secondary minerals, we consider the partial equilibrium assuming that the primary mineral dissolution is slow, and the secondary mineral precipitation is fast. Comparison of our modeling results with the mineralogical assemblages observed in the

  12. Life-cycle analysis results for geothermal systems in comparison to other power systems: Part II.

    SciTech Connect

    Sullivan, J.L.; Clark, C.E.; Yuan, L.; Han, J.; Wang, M.

    2012-02-08

    A study has been conducted on the material demand and life-cycle energy and emissions performance of power-generating technologies in addition to those reported in Part I of this series. The additional technologies included concentrated solar power, integrated gasification combined cycle, and a fossil/renewable (termed hybrid) geothermal technology, more specifically, co-produced gas and electric power plants from geo-pressured gas and electric (GPGE) sites. For the latter, two cases were considered: gas and electricity export and electricity-only export. Also modeled were cement, steel and diesel fuel requirements for drilling geothermal wells as a function of well depth. The impact of the construction activities in the building of plants was also estimated. The results of this study are consistent with previously reported trends found in Part I of this series. Among all the technologies considered, fossil combustion-based power plants have the lowest material demand for their construction and composition. On the other hand, conventional fossil-based power technologies have the highest greenhouse gas (GHG) emissions, followed by the hybrid and then two of the renewable power systems, namely hydrothermal flash power and biomass-based combustion power. GHG emissions from U.S. geothermal flash plants were also discussed, estimates provided, and data needs identified. Of the GPGE scenarios modeled, the all-electric scenario had the highest GHG emissions. Similar trends were found for other combustion emissions.

  13. Seal/lubricant systems for geothermal drilling equipment

    SciTech Connect

    Hendrickson, R.R.; Winzenried, R.W.

    1980-07-01

    The development and testing of seals and lubricants for journal-type roller-cone rock bits for drilling into geothermal reservoirs at temperatures over 260/sup 0/C (500/sup 0/F) are described. The conditions experienced by seals and lubricants subjected to geothermal drilling are reviewed along with the basic design requirements for roller-cone bit seals and journal bearing lubricants. Two unique test facilities are described: a seal test machine which simulates pressures, temperatures, and mechanical eccentricities, and a lubricant tester capable of evaluating load-bearing ability at temperature and pressure. Three candidate elastomeric compounds demonstrated 288/sup 0/C (550/sup 0/F) capability and several others demonstrated 260/sup 0/C (500/sup 0/F) or greater capability. Successful elastomeric seal candidates were proprietary compounds based on EPDM, Kalrez, and/or Viton polymers. Three mechanical seals for reservoir temperatures over 288/sup 0/C (550/sup 0/F) are presented. Lubricant screening tests on more than 50 products are summarized, and several newly developed lubricants which meet both the compatibility and lubrication requirements are described. Several seal/lubricant systems are recommended for laboratory or field geothermal drilling tests in roller-cone drill bits. The future availability of drill bits for geothermal use is discussed, as well as the potential spinoffs of the program findings for nongeothermal roller-cone bits.

  14. Geothermal aquaculture project: Real Property Systems Inc. , Harney Basin, Oregon

    SciTech Connect

    Not Available

    1981-08-14

    Real Property Systems Inc., (RPS) owns two parcels in the vicinity of Harney Lake, Oregon. One parcel is 120 acres in size, the other is 200 acres. A study concludes that the 200 acre parcel has the greater potential for geothermal development. RPS is interested in an aquaculture operation that produces fresh water prawns, (Macrobrachium rosenbergii) for the market. To supply the heat necessary to maintain the ideal temperature of 82/sup 0/F desired for these prawns, a geothermal resource having a 150/sup 0/F temperature or higher, is needed. The best estimate is that 150/sup 0/F water can be found from a minimum 1090 feet depth to 2625 feet, with no absolute assurances that sufficient quantities of geothermal waters exist without drilling for the same. This study undertakes the preliminary determination of project economics so that a decision can be made whether or not to proceed with exploratory drilling. The study is based on 10 acres of ponds, with a peak requirement of 2500 gpm of 150/sup 0/F geothermal water.

  15. Methanotrophic activity and bacterial diversity in volcanic-geothermal soils at Pantelleria island (Italy)

    NASA Astrophysics Data System (ADS)

    Gagliano, A. L.; D'Alessandro, W.; Tagliavia, M.; Parello, F.; Quatrini, P.

    2014-04-01

    Volcanic and geothermal systems emit endogenous gases by widespread degassing from soils, including CH4, a greenhouse gas twenty-five times as potent as CO2. Recently, it has been demonstrated that volcanic/geothermal soils are source of methane, but also sites of methanotrophic activity. Methanotrophs are able to consume 10-40 Tg of CH4 a-1 and to trap more than 50% of the methane degassing through the soils. We report on methane microbial oxidation in the geothermally most active site of Pantelleria island (Italy), Favara Grande, whose total methane emission was previously estimated in about 2.5 t a-1. Laboratory incubation experiments with three top-soil samples from Favara Grande indicated methane consumption values up to 950 ng g-1 dry soil h-1. One of the three sites, FAV2, where the highest oxidation rate was detected, was further analysed on a vertical soil profile and the maximum methane consumption was measured in the top-soil layer but values > 100 ng g-1 h-1 were maintained up to a depth of 15 cm. The highest consumption rate was measured at 37 °C, but a still recognizable consumption at 80 °C (> 20 ng g-1 h-1) was recorded. In order to estimate the bacterial diversity, total soil DNA was extracted from Favara Grande and analysed using a Temporal Temperature Gradient gel Electrophoresis (TTGE) analysis of the amplified bacterial 16S rRNA gene. The three soil samples were probed by PCR using standard proteobacterial primers and newly designed verrucomicrobial primers targeting the unique methane monooxygenase gene pmoA; the presence of methanotrophs was detected in sites FAV2 and FAV3, but not in FAV1, where harsher chemical-physical conditions and negligible methane oxidation were detected. The pmoA gene libraries from the most active site FAV2 pointed out a high diversity of gammaproteobacterial methanotrophs distantly related to Methylococcus/Methylothermus genera and the presence of the newly discovered acido-thermophilic methanotrophs

  16. Methanotrophic activity and diversity of methanotrophs in volcanic geothermal soils at Pantelleria (Italy)

    NASA Astrophysics Data System (ADS)

    Gagliano, A. L.; D'Alessandro, W.; Tagliavia, M.; Parello, F.; Quatrini, P.

    2014-10-01

    Volcanic and geothermal systems emit endogenous gases by widespread degassing from soils, including CH4, a greenhouse gas twenty-five times as potent as CO2. Recently, it has been demonstrated that volcanic or geothermal soils are not only a source of methane, but are also sites of methanotrophic activity. Methanotrophs are able to consume 10-40 Tg of CH4 a-1 and to trap more than 50% of the methane degassing through the soils. We report on methane microbial oxidation in the geothermally most active site of Pantelleria (Italy), Favara Grande, whose total methane emission was previously estimated at about 2.5 Mg a-1 (t a-1). Laboratory incubation experiments with three top-soil samples from Favara Grande indicated methane consumption values of up to 59.2 nmol g-1 soil d.w. h-1. One of the three sites, FAV2, where the highest oxidation rate was detected, was further analysed on a vertical soil profile, the maximum methane consumption was measured in the top-soil layer, and values greater than 6.23 nmol g-1 h-1 were still detected up to a depth of 13 cm. The highest consumption rate was measured at 37 °C, but a still detectable consumption at 80 °C (> 1.25 nmol g-1 h-1) was recorded. The soil total DNA extracted from the three samples was probed by Polymerase Chain Reaction (PCR) using standard proteobacterial primers and newly designed verrucomicrobial primers, targeting the unique methane monooxygenase gene pmoA; the presence of methanotrophs was detected at sites FAV2 and FAV3, but not at FAV1, where harsher chemical-physical conditions and negligible methane oxidation were detected. The pmoA gene libraries from the most active site (FAV2) pointed to a high diversity of gammaproteobacterial methanotrophs, distantly related to Methylocaldum-Metylococcus genera, and the presence of the newly discovered acido-thermophilic Verrucomicrobia methanotrophs. Alphaproteobacteria of the genus Methylocystis were isolated from enrichment cultures under a methane

  17. Boise geothermal system, western Snake River plain, Idaho

    SciTech Connect

    Wood, S.H.; Burnham, W.L.

    1984-07-01

    The Boise geothermal system lies in an area of high heat flow along the northern margin of the western Snake River plain. Exploratory drilling for petroleum and geothermal water, seismic reflection profiling, and regional gravity data permit construction of a detailed structure section across the western plain. A faulted acoustic basement of volcanic rocks lies at depths of 2400 to 6000 ft (730-1830 m) beneath late Cenozoic lacustrine and fluvial deposits in the center of the plain. Volcanic rocks of the acoustic basement are typically basalt out in the plain, but the acoustic basement along the north margin in the vicinity of Boise is largely silicic volcanic rock. Geologic mapping and geothermal well data have provided information on the late Cenozoic geologic units and structures important to the understanding of the Boise geothermal system. The main geothermal aquifer is a sequence of rhyolite layers and minor arkosic and tuffaceous sediment of the Miocene Idavada Volcanics. The aquifer is confined by a sequence of impermeable basaltic tuffs. The aquifer has sufficient fracture permeability to yield 150/sup 0/-170/sup 0/F (65/sup 0/-76.6/sup 0/C) hot water for space heating at a rate of 600 to 1200 gpm from wells drilled in the metropolitan area, north of the Boise River. In this area the rhyolite lies at a depth of 900-2000 ft (274-610 m). Artesian pressure typically lifts water to an elevation of about 2760 ft (840 m). A conceptual model of recharge assumes percolation driven by the topographic head to a depth of more than 7000 ft (2135 m) beneath the granitic highlands northeast of the city. Heated water convects upward through northwest-trending range-front faults.

  18. Current California legislative and regulatory activity impacting geothermal hydrothermal commercialization: a monitoring report. Report No. 1017

    SciTech Connect

    Not Available

    1980-01-20

    Four key geothermal-impacting bills presently before the California legislature are described. Two deal with state financial backing for geothermal projects. The third relates to the use of the state's share of the BLM geothermal revenues and the fourth to the protection of sensitive hot springs. The current regulatory activities of the California Energy Commission, the California Division of Oil and Gas, and the counties are discussed. (MHR)

  19. STRUCTURAL CONTROLS OF THE EMERSON PASS GEOTHERMAL SYSTEM, NORTHWESTERN NEVADA: CHARACTERIZATION OF A "BLIND" SYSTEM

    SciTech Connect

    Anderson, Ryan B; Faulds, James E

    2013-10-27

    The Pyramid Lake area is favorable for geothermal development due to the tectonic setting of the region. The Walker Lane belt, a dextral shear zone that accommodates ~20% relative motion between the Pacific and North American plates, terminates northwestward in northeast California. NW-directed dextral shear is transferred to WNW extension accommodated by N-to -NNE striking normal faults of the Basin and Range. As a consequence, enhanced dilation occurs on favorably oriented faults generating high geothermal potential in the northwestern Great Basin. The NW-striking right-lateral Pyramid Lake fault, a major structure of the northern Walker Lane, terminates at the southern end of Pyramid Lake and transfers strain to the NNE-striking down to the west Lake Range fault, resulting in high geothermal potential. Known geothermal systems in the area have not been developed due to cultural considerations of the Pyramid Lake Paiute Tribe. Therefore, exploration has been focused on discovering blind geothermal systems elsewhere on the reservation by identifying structurally favorable settings and indicators of past geothermal activity. One promising area is the northeast end of Pyramid Lake, where a broad left step between the west-dipping range-bounding faults of the Lake and Fox Ranges has led to the formation of a broad, faulted relay ramp. Furthermore, tufa mounds, mineralized veins, and altered Miocene rocks occur proximal to a thermal anomaly discovered by a 2-m shallow temperature survey at the north end of the step-over in Emerson Pass. Detailed geologic mapping has revealed a system of mainly NNE-striking down to the west normal faults. However, there are three notable exceptions to this generality, including 1) a prominent NW-striking apparent right-lateral fault, 2) a NW-striking down to the south fault which juxtaposes the base of the mid-Miocene Pyramid sequence against younger late Tertiary sedimentary rocks, and 3) a NNE-striking down to the east normal fault

  20. Community Geothermal Technology Program: Bottom heating system using geothermal power for propagation. Final report, Phases 1 and 2

    SciTech Connect

    Downing, J.C.

    1990-01-01

    The objective is to develop and study a bottom-heating system in a greenhouse utilizing geothermal energy to aid germination and speed growth of palms. Source of heat was geothermal brine from HGP-A well. The project was successful; the heat made a dramatic difference with certain varieties, such as Areca catechu (betelnut) with 82% germination with heat, zero without. For other varieties, germination rates were much closer. Quality of seed is important. Tabs, figs.

  1. Engineered Geothermal Systems Energy Return On Energy Investment

    SciTech Connect

    Mansure, A J

    2012-12-10

    Energy Return On Investment (EROI) is an important figure of merit for assessing the viability of energy alternatives. Too often comparisons of energy systems use efficiency when EROI would be more appropriate. For geothermal electric power generation, EROI is determined by the electricity delivered to the consumer compared to the energy consumed to construct, operate, and decommission the facility. Critical factors in determining the EROI of Engineered Geothermal Systems (EGS) are examined in this work. These include the input energy embodied into the system. Embodied energy includes the energy contained in the materials, as well as, that consumed in each stage of manufacturing from mining the raw materials to assembling the finished system. Also critical are the system boundaries and value of the energy heat is not as valuable as electrical energy. The EROI of an EGS depends upon a number of factors that are currently unknown, for example what will be typical EGS well productivity, as well as, reservoir depth, temperature, and temperature decline rate. Thus the approach developed is to consider these factors as parameters determining EROI as a function of number of wells needed. Since the energy needed to construct a geothermal well is a function of depth, results are provided as a function of well depth. Parametric determination of EGS EROI is calculated using existing information on EGS and US Department of Energy (DOE) targets and is compared to the minimum EROI an energy production system should have to be an asset rather than a liability.

  2. Environmental impacts of open loop geothermal system on groundwater

    NASA Astrophysics Data System (ADS)

    Kwon, Koo-Sang; Park, Youngyun; Yun, Sang Woong; Lee, Jin-Yong

    2013-04-01

    Application of renewable energies such as sunlight, wind, rain, tides, waves and geothermal heat has gradually increased to reduce emission of CO2 which is supplied from combustion of fossil fuel. The geothermal energy of various renewable energies has benefit to be used to cooling and heating systems and has good energy efficiency compared with other renewable energies. However, open loop system of geothermal heat pump system has possibility that various environmental problems are induced because the system directly uses groundwater to exchange heat. This study was performed to collect data from many documents such as papers and reports and to summarize environmental impacts for application of open loop system. The environmental impacts are classified into change of hydrogeological factors such as water temperature, redox condition, EC, change of microbial species, well contamination and depletion of groundwater. The change of hydrogeological factors can induce new geological processes such as dissolution and precipitation of some minerals. For examples, increase of water temperature can change pH and Eh. These variations can change saturation index of some minerals. Therefore, dissolution and precipitation of some minerals such as quartz and carbonate species and compounds including Fe and Mn can induce a collapse and a clogging of well. The well contamination and depletion of groundwater can reduce available groundwater resources. These environmental impacts will be different in each region because hydrogeological properties and scale, operation period and kind of the system. Therefore, appropriate responses will be considered for each environmental impact. Also, sufficient study will be conducted to reduce the environmental impacts and to improve geothermal energy efficiency during the period that a open loop system is operated. This work was supported by the Energy Efficiency and Resources of the Korea Institute of Energy Technology Evaluation and Planning

  3. ­­Fault scaling and permeability controls in geothermal systems

    NASA Astrophysics Data System (ADS)

    Siler, D. L.; Hinz, N.

    2014-12-01

    Geologic structures play a crucial role in focusing geothermal fluid circulation in the upper crust. In a variety of geothermal provinces worldwide, studies have shown that young or active faults, and especially locations where faults intersect and interact, generate the accentuated fracture permeability required for geothermal circulation. Fault intersection and interaction areas are characterized by concentrated stresses, which leads to the generation of secondary faults and fractures and heightened permeability. In the Great Basin, USA, fault terminations, fault step-overs (or relay ramps) and accommodation zones are among the most common structural settings for geothermal circulation. Fault scaling relationships provide a first-order indication of the ideal extent and geometry of these features as well as the location(s) and extent of concentrated stresses (and therefore a high potential for permeability generation) within these structures. The most favorable locations for fracture permeability, those with optimal stress concentrations, are on the order of ~1-2 km wide for typical 10-20 km fault lengths in the Great Basin. Examination of known, production geothermal systems within each of these structural settings indicates that although thermal anomalies are commonly 5-10 km wide, the production reservoir and corresponding well fields are confined to smaller areas. We suggest that the limited aerial extent of these production zones is controlled by the extent of concentrated stresses and the most accentuated fracture permeability associated the specific fault intersection or interaction areas. Though is it well established that specific structural geometries like fault terminations, step-overs and accommodation zones are promising 'plays' for geothermal exploration, our analysis further constrains the scale and extent of the most favorable occurrences of these structures, as well as the most prospective permeability zones within them.

  4. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Final report, March 1, 1979-September 30, 1984

    SciTech Connect

    Smith, K.

    1984-09-01

    This final report documents the Navarro College geothermal use project, which is one of nineteen direct-use geothermal projects funded principally by DOE. The six-year project encompassed a broad range of technical, institutional, and economic activities including: resource and environmental assessment; well drilling and completion; system design, construction, and monitoring; economic analysis; and public awareness programs. Some of the project conclusions are that: (1) the 130/sup 0/F Central Texas geothermal resource can support additional geothermal development; (2) private sector economic incentives currently exist which encourage commercial development of this geothermal resource; (3) potential uses for this geothermal resource include water and space heating, aquacultural and agricultural heating uses, and fruit and vegetable dehydration; (4) high maintenance costs arising from the geofluids' scaling and corrosion characteristics can be avoided through proper analysis and design.

  5. Natural analogs for enhanced heat recovery from geothermal systems

    SciTech Connect

    Nielson, Dennis L.

    1996-01-24

    High-temperature hydrothermal systems are physically and chemically zoned with depth. The energy input is from a magmatic zone, intruded by igneous bodies, that may also contribute variable amounts of magmatic fluid to the system. The heat source is directly overlain by a section of rocks, that due to their elevated temperature, respond to stress in a ductile fashion. The ductile zone is, in turn, overlain by a section of rocks that respond to stress in a brittle fashion, where water is able to circulate through fractures (the geothermal reservoir) and will be termed the hydrothermal circulation zone. Ancient and modern high-temperature geothermal systems show a predictable sequence of evolutionary events affecting these stratified zones. Metamorphic core complexes are uplifts, formed in highly extended terrains, that expose fossil brittle-ductile transition zones. Formerly ductile rocks have had brittle fractures superimposed on them, and meteoric hydrothermal systems are associated with the brittle fracturing. Porphyry copper deposits typically evolve from magmatic to meteoric hydrothermal systems. At the Larderello geothermal system, the brittle- ductile transition has been mapped using reflection seismology, and the zone has been penetrated by the San Pompeo 2 well where temperatures >420°C were encountered. Although neo-granitic dikes have been penetrated by drilling in the Larderello area, the brittle- ductile transition is largely above the inferred plutonic heat source. In the Geysers system, in contrast, the present steam system has been superimposed on young plutonic rocks and the inferred brittle-ductile transition is present at a depth of about 4.7 km within the plutonic rocks. As hydrothermal reservoirs are depleted, or surface facilities are restricted by environmental considerations, interest will turn to the deeper portions of known systems. Japan already has an aggressive program to develop Deep-seated and Magma-Ambient resources. This program, as

  6. An Integrated Chemical Geothermometry System for Geothermal Exploration

    NASA Astrophysics Data System (ADS)

    Spycher, N. F.; Sonnenthal, E. L.; Kennedy, B. M.

    2010-12-01

    The objective of this project is to develop a reliable and improved methodology to predict geothermal reservoir temperatures from full and integrated chemical analyses of spring and shallow well water samples, to see through near surface processes, such as dilution, gas loss, etc., that mask or hide the chemical signatures of deep reservoir fluids in near surface waters. The system builds on a multicomponent chemical geothermometry method developed previously for single point sources relying on computed saturation indices of multiple minerals. Taking advantage of recent advances in optimization and geochemical/reactive transport modeling, the system integrates the multicomponent geothermometry method into an optimization system that allows simultaneous processing of multiple water analyses to estimate reservoir temperatures. In doing so, the system will also be able to solve for amounts and compositions of potential mixing end-members diluting the reservoir fluids and/or composition and amounts of gas phase lost as deep geothermal fluids ascend to ground surface. This integrated approach is expected to allow estimations of reservoir temperatures with better reliability and consistency than currently possible using standard chemical geothermometers. The proposed approach is being implemented and tested using an extensive set of water and gas compositions from springs and wells at the geothermal system in Dixie Valley, Nevada, where standard chemical geothermometers yield temperatures inconsistent with measured reservoir temperatures.

  7. Thermally conductive cementitious grout for geothermal heat pump systems

    DOEpatents

    Allan, Marita

    2001-01-01

    A thermally conductive cement-sand grout for use with a geothermal heat pump system. The cement sand grout contains cement, silica sand, a superplasticizer, water and optionally bentonite. The present invention also includes a method of filling boreholes used for geothermal heat pump systems with the thermally conductive cement-sand grout. The cement-sand grout has improved thermal conductivity over neat cement and bentonite grouts, which allows shallower bore holes to be used to provide an equivalent heat transfer capacity. In addition, the cement-sand grouts of the present invention also provide improved bond strengths and decreased permeabilities. The cement-sand grouts can also contain blast furnace slag, fly ash, a thermoplastic air entraining agent, latex, a shrinkage reducing admixture, calcium oxide and combinations thereof.

  8. Seismic tomography and dynamics of geothermal and natural hydrothermal systems in the south of Bandung, Indonesia

    NASA Astrophysics Data System (ADS)

    Jousset, Philippe; Sule, Rachmat; Diningrat, Wahyuddin; Syahbana, Devy; Schuck, Nicole; Akbar, Fanini; Kusnadi, Yosep; Hendryana, Andri; Nugraha, Andri; Ryannugroho, Riskiray; Jaya, Makki; Erbas, Kemal; Bruhn, David; Pratomo, Bambang

    2015-04-01

    The structure and the dynamics of geothermal reservoirs and hydrothermal systems allows us to better assess geothermal resources in the south of Bandung. A large variety of intense surface manifestations like geysers, hot-steaming grounds, hot water pools, and active volcanoes suggest an intimate coupling between volcanic, tectonic and hydrothermal processes in this area. We deployed a geophysical network around geothermal areas starting with a network of 30 seismic stations including high-dynamic broadband Güralp and Trillium sensors (0.008 - 100 Hz) and 4 short-period (1 Hz) sensors from October 2012 to December 2013. We extended the network in June 2013 with 16 short-period seismometers. Finally, we deployed a geodetic network including a continuously recording gravity meter, a GPS station and tilt-meters. We describe the set-up of the seismic and geodetic networks and we discuss observations and results. The earthquakes locations were estimated using a non-linear algorithm, and revealed at least 3 seismic clusters. We perform joint inversion of hypo-center and velocity tomography and we look at seismic focal mechanisms. We develop seismic ambient noise tomography. We discuss the resulting seismic pattern within the area and relate the structure to the distribution of hydrothermal systems. We aim at searching possible structural and dynamical links between different hydrothermal systems. In addition, we discuss possible dynamical implications of this complex volcanic systems from temporal variations of inferred parameters. The integration of those results allows us achieving a better understanding of the structures and the dynamics of those geothermal reservoirs. This approach contributes to the sustainable and optimal exploitation of the geothermal resource in Indonesia.

  9. 3D Geological Model for "LUSI" - a Deep Geothermal System

    NASA Astrophysics Data System (ADS)

    Sohrabi, Reza; Jansen, Gunnar; Mazzini, Adriano; Galvan, Boris; Miller, Stephen A.

    2016-04-01

    Geothermal applications require the correct simulation of flow and heat transport processes in porous media, and many of these media, like deep volcanic hydrothermal systems, host a certain degree of fracturing. This work aims to understand the heat and fluid transport within a new-born sedimentary hosted geothermal system, termed Lusi, that began erupting in 2006 in East Java, Indonesia. Our goal is to develop conceptual and numerical models capable of simulating multiphase flow within large-scale fractured reservoirs such as the Lusi region, with fractures of arbitrary size, orientation and shape. Additionally, these models can also address a number of other applications, including Enhanced Geothermal Systems (EGS), CO2 sequestration (Carbon Capture and Storage CCS), and nuclear waste isolation. Fractured systems are ubiquitous, with a wide-range of lengths and scales, making difficult the development of a general model that can easily handle this complexity. We are developing a flexible continuum approach with an efficient, accurate numerical simulator based on an appropriate 3D geological model representing the structure of the deep geothermal reservoir. Using previous studies, borehole information and seismic data obtained in the framework of the Lusi Lab project (ERC grant n°308126), we present here the first 3D geological model of Lusi. This model is calculated using implicit 3D potential field or multi-potential fields, depending on the geological context and complexity. This method is based on geological pile containing the geological history of the area and relationship between geological bodies allowing automatic computation of intersections and volume reconstruction. Based on the 3D geological model, we developed a new mesh algorithm to create hexahedral octree meshes to transfer the structural geological information for 3D numerical simulations to quantify Thermal-Hydraulic-Mechanical-Chemical (THMC) physical processes.

  10. High Temperature Components of Magma-Related Geothermal Systems: An Experimental and Theoretical Approach

    SciTech Connect

    Philip A. Candela; Philip M. Piccoli

    2004-03-15

    This summarizes select components of a multi-faceted study of high temperature magmatic fluid behavior in shallow, silicic, volcano-plutonic geothermal systems. This work built on a foundation provided by DOE-supported advances made in our lab in understanding the physics and chemistry of the addition of HCI and other chlorides into the high temperature regions of geothermal systems. The emphasis of this project was to produce a model of the bolatile contributions from felsic magmatic systems to geothermal systems

  11. Vertical arrays for fracture mapping in geothermal systems

    SciTech Connect

    Albright, J.N.; Rutledge, J.T.; Fairbanks, T.D.; Thomson, J.C.; Stevenson, M.A.

    1998-12-01

    In collaboration with UNOCAL Geothermal Operations, Los Alamos National Laboratory assessed the feasibility of using vertical arrays of borehole seismic sensors for mapping of microseismicity in The Geysers geothermal field. Seismicity which arises from minute displacements along fracture or fault surfaces has been shown in studies of seismically active oil reservoirs to be useful in identifying fractures affected by and possibly contributing to production. Use of retrievable borehole seismic packages at The Geysers was found to reduce the threshold for detection of microearthquakes by an estimated 2--3 orders of magnitude in comparison to surface-based sensors. These studies led to the design, materials selection, fabrication, and installation of a permanent array of geophones intended for long term seismic monitoring and mapping of fractures in the vicinity of the array at The Geysers.

  12. Geothermal district heating system feasibility analysis, Thermopolis, Wyoming

    SciTech Connect

    Goering, S.W.; Garing, K.L.; Coury, G.; Mickley, M.C.

    1982-04-26

    The purpose of this study is to determine the technical and economic feasibility of constructing and operating a district heating system to serve the residential, commercial, and public sectors in Thermopolis. The project geothermal resource assessment, based on reviews of existing information and data, indicated that substantial hot water resources likely exist in the Rose Dome region 10 miles northeast of Thermopolis, and with quantities capable of supporting the proposed geothermal uses. Preliminary engineering designs were developed to serve the space heating and hot water heating demands for buildings in the Thermopolis-East Thermopolis town service area. The heating district design is based on indirect geothermal heat supply and includes production wells, transmission lines, heat exchanger units, and the closed loop distribution and collection system necessary to serve the individual customers. Three options are presented for disposal of the cooled waters-reinjection, river disposal, and agricultural reuse. The preliminary engineering effort indicates the proposed system is technically feasible. The design is sized to serve 1545 residences, 190 businesses, and 24 public buildings. The peak design meets a demand of 128.2 million Btu at production rates of 6400 gpm.

  13. Geothermal Energy.

    ERIC Educational Resources Information Center

    Bufe, Charles Glenn

    1983-01-01

    Major activities, programs, and conferences in geothermal energy during 1982 are highlighted. These include first comprehensive national assessment of U.S. low-temperature geothermal resources (conducted by U.S. Geological Survey and Department of Energy), map production by U.S. Geological Survey, geothermal plant production, and others. (JN)

  14. Middlesex Community College Geothermal Project

    SciTech Connect

    Klein, Jessie; Spaziani, Gina

    2013-03-29

    The purpose of the project was to install a geothermal system in the trustees house on the Bedford campus of Middlesex Community College. In partnership with the environmental science faculty, learning activities for environmental science courses were developed to explain geothermal energy and more specifically the newly installed system to Middlesex students. A real-time monitoring system highlights the energy use and generation.

  15. Geothermal energy program overview

    NASA Astrophysics Data System (ADS)

    1991-12-01

    The mission of the Geothermal Energy Program is to develop the science and technology necessary for tapping our nation's tremendous heat energy sources contained within the Earth. Geothermal energy is a domestic energy source that can produce clean, reliable, cost-effective heat and electricity for our nation's energy needs. Geothermal energy - the heat of the Earth - is one of our nation's most abundant energy resources. In fact, geothermal energy represents nearly 40 percent of the total U.S. energy resource base and already provides an important contribution to our nation's energy needs. Geothermal energy systems can provide clean, reliable, cost-effective energy for our nation's industries, businesses, and homes in the form of heat and electricity. The U.S. Department of Energy's (DOE) Geothermal Energy Program sponsors research aimed at developing the science and technology necessary for utilizing this resource more fully. Geothermal energy originates from the Earth's interior. The hottest fluids and rocks at accessible depths are associated with recent volcanic activity in the western states. In some places, heat comes to the surface as natural hot water or steam, which have been used since prehistoric times for cooking and bathing. Today, wells convey the heat from deep in the Earth to electric generators, factories, farms, and homes. The competitiveness of power generation with lower quality hydrothermal fluids, geopressured brines, hot dry rock, and magma (the four types of geothermal energy), still depends on the technical advancements sought by DOE's Geothermal Energy Program.

  16. Geothermal Energy Program overview

    SciTech Connect

    Not Available

    1991-12-01

    The mission of the Geothermal Energy Program is to develop the science and technology necessary for tapping our nation's tremendous heat energy sources contained with the Earth. Geothermal energy is a domestic energy source that can produce clean, reliable, cost- effective heat and electricity for our nation's energy needs. Geothermal energy -- the heat of the Earth -- is one of our nation's most abundant energy resources. In fact, geothermal energy represents nearly 40% of the total US energy resource base and already provides an important contribution to our nation's energy needs. Geothermal energy systems can provide clean, reliable, cost-effective energy for our nation's industries, businesses, and homes in the form of heat and electricity. The US Department of Energy's (DOE) Geothermal Energy Program sponsors research aimed at developing the science and technology necessary for utilizing this resource more fully. Geothermal energy originates from the Earth's interior. The hottest fluids and rocks at accessible depths are associated with recent volcanic activity in the western states. In some places, heat comes to the surface as natural hot water or steam, which have been used since prehistoric times for cooking and bathing. Today, wells convey the heat from deep in the Earth to electric generators, factories, farms, and homes. The competitiveness of power generation with lower quality hydrothermal fluids, geopressured brines, hot dry rock, and magma ( the four types of geothermal energy) still depends on the technical advancements sought by DOE's Geothermal Energy Program.

  17. Geology of the Beowawe geothermal system, Eureka and Lander Counties, Nevada

    SciTech Connect

    Struhsacker, E.M.

    1980-07-01

    A geologic study is described undertaken to evaluate the nature of structural and stratigraphic controls within the Beowawe geothermal system, Eureka and Lander Counties, Nevada. This study includes geologic mapping at a scale of 1:24,000 and lithologic logs of deep Chevron wells. Two major normal fault systems control the configuration of the Beowawe geothermal system. Active hot springs and sinter deposits lie along the Malpais Fault zone at the base of the Malpais Rim. The Malpais Rim is one of several east-northeast-striking, fault-bounded cuestas in north central Nevada. A steeply inclined scarp slope faces northwest towards Whirlwind Valley. The general inclination of the volcanic rocks on the Malpais dip slope is 5/sup 0/ to 10/sup 0/ southeast.

  18. Completion Design Considerations for a Horizontal Enhanced Geothermal System

    SciTech Connect

    Olson, Jeffrey; Eustes, Alfred; Fleckenstein, William; Eker, Erdinc; Baker, Reed; Augustine, Chad

    2015-09-02

    The petroleum industry has had considerable success in recent decades in developing unconventional shale plays using horizontal drilling and multi-zonal isolation and stimulation techniques to fracture tight formations to enable the commercial production of oil and gas. Similar well completions could be used in Enhanced Geothermal Systems (EGS) to create multiple fractures from horizontal wells. This study assesses whether well completion techniques used in the unconventional shale industry to create multi-stage fractures can be applied to an enhanced geothermal system, with a focus on the completion of the EGS injection well. This study assumes an Enhanced Geothermal System (EGS) consisting of a central horizontal injection well flanked on each side by horizontal production wells, connected to the injection well by multiple fractures. The focus is on the design and completion of the horizontal well. For the purpose of developing design criteria, a reservoir temperature of 200 degrees C (392 degrees F) and an injection well flow rate of 87,000 barrels per day (160 kg/s), corresponding to production well flow rates of 43,500 barrels per day (80 kg/s) is assumed. The analysis found that 9-5/8 inches 53.5 pounds per foot (ppf) P110 casing string with premium connections meets all design criteria for the horizontal section of injection well. A P110 grade is fairly common and is often used in horizontal sections of shale development wells in petroleum operations. Next, several zonal isolation systems commonly used in the shale gas industry were evaluated. Three techniques were evaluated -- a 'plug and perf' design, a 'sand and perf' design, and a 'packer and port' design. A plug and perf system utilizes a cemented casing throughout the length of the injector wellbore. The sand and perf system is identical to the plug and perf system, but replaces packers with sand placed in the casing after stimulation to screen out the stimulated perforated zones and provide zonal

  19. Natural analogs for enhanced heat recovery from geothermal systems

    SciTech Connect

    Nielson, D.L.

    1996-12-31

    High-temperature hydrothermal systems are physically and chemically zoned with depth. The energy input is from a magmatic zone, intruded by igneous bodies, that may also contribute variable amounts of magmatic fluid to the system. The heat source is directly overlain by a section of rocks, that due to their elevated temperature, respond to stress in a ductile fashion. The ductile zone is, in turn, overlain by a section of rocks that respond to stress in a brittle fashion, where water is able to circulate through fractures (the geothermal reservoir) and will be termed the hydrothermal circulation zone. Ancient and modern high-temperature geothermal systems show a predictable sequence of evolutionary events affecting these stratified zones. Metamorphic core complexes are uplifts, formed in highly extended terrains, that expose fossil brittle-ductile transition zones. Formerly ductile rocks have had brittle fractures superimposed on them, and meteoric hydrothermal systems are associated with the brittle fracturing. Porphyry copper deposits typically evolve from magmatic to meteoric hydrothermal systems. At the Larderello geothermal system, the brittle-ductile transition has been mapped using reflection seismology, and the zone has been penetrated by the San Pompeo 2 well where temperatures >420{degrees}C were encountered. Although neo-granitic dikes have been penetrated by drilling in the Larderello area, the brittle-ductile transition is largely above the inferred plutonic heat source. In the Geysers system, in contrast, the present steam system has been superimposed on young plutonic rocks and the inferred brittle-ductile transition is present at a depth of about 4.7 km within the plutonic rocks. As hydrothermal reservoirs are depleted, or surface facilities are restricted by environmental considerations, interest will turn to the deeper portions of known systems. Japan already has an aggressive program to develop Deep-Seated and Magma-Ambient resources.

  20. Absence of Remote Triggering in Geothermal Fields Due to Human Activity

    NASA Astrophysics Data System (ADS)

    Ge, S.; Zhang, Q.; Lin, G.

    2014-12-01

    Operational geothermal fields typically have high seismicity rates, which could be caused by both tectonic and anthropogenic activities. Due to the high background seismicity and possible interaction between fluid and seismic waves, geothermal areas have been recognized to be susceptible to large remote earthquakes. However, whether human activity (geothermal production) affects remote earthquake triggering by changing the stress state is unclear. Here we choose two geothermal fields, Coso and Salton Sea in southern California, to study the spatiotemporal distributions of the triggered earthquakes following the 1992 Mw 7.3 Landers and 1999 Mw 7.1 Hector Mine earthquakes. These two geothermal fields have been in operation since 1980s with comparable net capacity, and have long-term geothermal fluid loss. By analyzing the regional catalog recorded by the Southern California Seismic Network, we find that these two operational geothermal areas remain unaffected by the remote mainshocks, whereas the surrounding areas show vigorous triggered responses. We interpret this phenomenon as a result of human activity, which presumably has brought the stress state away from failure by reducing pore pressure. To further understand how much the human activity can affect the stress state, we also conduct a systematic study on Long Valley Caldera in northern California as a comparison site. Long Valley Caldera hosts an active geothermal field with net capacity about one sixth of that in Coso or Salton Sea geothermal field, and the extraction volume is not constantly larger than the injection. We will show comparisons of the triggered response in Long Valley with the two geothermal fields in southern California.

  1. Feasibility study of sedimentary enhanced geothermal systems using reservoir simulation

    NASA Astrophysics Data System (ADS)

    Cho, Jae Kyoung

    investigated. Especially, water density, viscosity and rock heat capacity play a significant role in reservoir performance. The Permian Lyons formation in the Denver Basin is selected for this preliminary study. Well log data around the area of interest are collected and borehole temperature data are analyzed to estimate the geothermal potential of the target area and it follows that the target formation has a geothermal gradient as high as 72 °C/km. Based on the well log data, hypothetical reservoir simulation models are build and tested to access the hydraulic and thermal performance. It turns out that the target formation is marginally or sub-marginally commercial in terms of its formation conductivity. Therefore, the target formation may require reservoir stimulation for commercially viable power generation. Lastly, reservoir simulation models with average petrophysical properties obtained from the well log analysis of the target formation are built. In order to account for overburden and underburden heat transfer for confined reservoirs, low permeability layers representing shale cap/bed rocks are attached to the top and bottom of the reservoir layers. The dual permeability concept is applied to the reservoir layers to model induced fracture networks by reservoir stimulation. The simulation models are tested by changing fracture conductivity and shape factor. The results show that a balance between hydraulic and thermal performance should be achieved to meet the target flow rate and sustainability of 30 years' uninterrupted operation of geothermal electricity power generation. Ineffective reservoir stimulation could result in failing to create a producing reservoir with appropriate productivity index or causing premature thermal breakthrough or short-circuiting which advances the end of geothermal systems. Therefore, Enhanced Geothermal Systems (EGS) should be engineered to secure producing performance and operational sustainability simultaneously.

  2. Off peak geothermal heat pump storage system

    SciTech Connect

    Drake, M.S.

    1986-03-01

    The basic design of a system installed in the Columbus, Ohio Zoo is described. The distribution system is described in detail. The control system is microprocessor controlled, with about 50 monitoring points. Preliminary evaluations have indicated that the system can operate with an overall coefficient of performance in excess of 3.5. 1 figure.

  3. Hydrocarbon anomaly in soil gas as near-surface expressions of upflows and outflows in geothermal systems

    SciTech Connect

    Ong, H.L.; Higashihara, M.; Klusman, R.W.; Voorhees, K.J.; Pudjianto, R.; Ong, J

    1996-01-24

    A variety of hydrocarbons, C1 - C12, have been found in volcanic gases (fumarolic) and in geothermal waters and gases. The hydrocarbons are thought to have come from products of pyrolysis of kerogen in sedimentary rocks or they could be fed into the geothermal system by the recharging waters which may contain dissolved hydrocarbons or hydrocarbons extracted by the waters from the rocks. In the hot geothermal zone, 300°+ C, many of these hydrocarbons are in their critical state. It is thought that they move upwards due to buoyancy and flux up with the upflowing geothermal fluids in the upflow zones together with the magmatic gases. Permeability which could be provided by faults, fissures, mini and micro fractures are thought to provide pathways for the upward flux. A sensitive technique (Petrex) utilizing passive integrative adsorption of the hydrocarbons in soil gas on activated charcoal followed by desorption and analysis of the hydrocarbons by direct introduction mass spectrometry allows mapping of the anomalous areas. Surveys for geothermal resources conducted in Japan and in Indonesia show that the hydrocarbon anomaly occur over known fields and over areas strongly suspected of geothermal potential. The hydrocarbons found and identified were n-paraffins (C7-C9) and aromatics (C7-C8). Detection of permeable, i.e. active or open faults, parts of older faults which have been reactivated, e.g. by younger intersecting faults, and the area surrounding these faulted and permeable region is possible. The mechanism leading to the appearance of the hydrocarbon in the soil gas over upflow zones of the geothermal reservoir is proposed. The paraffins seems to be better pathfinders for the location of upflows than the aromatics. However the aromatics may, under certain circumstances, give better indications of the direction of the outflow of the geothermal system. It is thought that an upflow zone can be

  4. Validation of hydrogeochemical codes using the New Zealand geothermal system

    SciTech Connect

    Glassley, W.

    1992-12-01

    Evaluation of the performance of a nuclear waste repository requires that numerous parameters be evaluated over a broad range of conditions using codes. The capabilities of these codes must be demonstrated using complex natural systems in which the processes of interest have already occurred or are occurring. We have initiated such a test of geochemical and hydrological simulation codes, using the geothermal areas of the Taupo Volcanic Zone, New Zealand. Areas that have been evolving for a few tens to a few tens of thousands of years are of particular interest. This effort will help determine the extent to which simplified modeling approaches can be used in performance assessment calculations. To guide the selection of natural systems, we are attempting to map potential repository regions dominated by equilibrium processes and those dominated by kinetically controlled processes. To do so, fluid velocities and temperatures were computed using the V-TOUGH code assuming an equivalent continuum, dual porosity model. These results were then used to compare advective fluid flow rate with silica dissolution/precipitation rates, using Damkoehler numbers. Only the first 5000 years of repository operation were considered. The results identify a migrating envelope of kinetically dominated activity several meters wide in the vicinity of waste packages that contrasts with other parts of the repository. The Lake Rotokawa region, New Zealand, has been used in our first test effort, since it contains environments that are examples of kinetic and equilibrium processes. The results of tests involving equilibrium processes show excellent correspondence between simulated and observed mineral alteration sequences, although discrepancies in some mineral parageneses demonstrate that operator decisions in conducting simulations must be considered an integral part of validation efforts.

  5. Sperry Low Temperature Geothermal Conversion System, Phase 1 and Phase II. Final report. Volume III. Systems description

    SciTech Connect

    Matthews, H.B.

    1984-01-01

    The major fraction of hydrothermal resources that have the prospect of being economically useful for the generation of electricity are in the 300/sup 0/F to 425/sup 0/F temperature range. Cost-effective conversion of the geothermal energy to electricity requires the conception and reduction to practice of new ideas to improve conversion efficiency, enhance brine flow, reduce plant costs, increase plant availability, and shorten the time between investment and return. The problems addressed during past activities are those inherent in the geothermal environment, in the binary fluid cycle, in the difficulty of efficiently converting the energy of a low-temperature resource, and in geothermal economics. Explained in detail in this document, some of these problems are: the energy expended by the down-hole pump; the difficulty in designing reliable down-hole equipment; fouling of heat-exchanger surfaces by geothermal fluids; the unavailability of condenser cooling water at most geothermal sites; the large portion of the available energy used by the feed pump in a binary system; the pinch effect - a loss in available energy in transferring heat from water to an organic fluid; flow losses in fluids that carry only a small amount of useful energy to begin with; high heat-exchanger costs - the lower the temperature interval of the cycle, the higher the heat exchanger costs in $/kW (actually, more than inversely proportional); the complexity and cost of the many auxiliary elements of proposed geothermal plants; and the unfortunate cash flow vs. investment curve caused by the many years of investment required to bring a field into production before any income is realized.

  6. Thermal Infrared Remote Sensing of the Yellowstone Geothermal System

    NASA Astrophysics Data System (ADS)

    Vaughan, R. G.; Keszthelyi, L. P.; Heasler, H.; Jaworowski, C.; Lowenstern, J. B.; Schneider, D. J.

    2009-12-01

    The Yellowstone National Park (YNP) geothermal system is one of the largest in the world, with thousands of individual thermal features ranging in size from a few centimeters to tens of meters across, (e.g., fumaroles, geysers, mud pots and hot spring pools). Together, large concentrations of these thermal features make up dozens of distinct thermal areas, characterized by sparse vegetation, hydrothermally altered rocks, and usually either sinter, travertine, or acid sulfate alteration. The temperature of these thermal features generally ranges from ~30 to ~93 oC, which is the boiling temperature of water at the elevation of Yellowstone. In-situ temperature measurements of various thermal features are sparse in both space and time, but they show a dynamic time-temperature relationship. For example, as geysers erupt and send pulses of warm water down slope, the warm water cools rapidly and is then followed by another pulse of warm water, on time scales of minutes. The total heat flux from the Park’s thermal features has been indirectly estimated from chemical analysis of Cl- flux in water flowing from Yellowstone’s rivers. We are working to provide a more direct measurement, as well as estimates of time variability, of the total heat flux using satellite multispectral thermal infrared (TIR) remote sensing data. Over the last 10 years, NASA’s orbiting ASTER and MODIS instruments have acquired hundreds and thousands of multispectral TIR images, respectively, over the YNP area. Compared with some volcanoes, Yellowstone is a relatively low-temperature geothermal system, with low thermal contrast to the non-geothermal surrounding areas; therefore we are refining existing techniques to extract surface temperature and thermal flux information. This task is complicated by issues such as, during the day, solar heated surfaces may be warmer than nearby geothermal features; and there is some topographic (elevation) influence on surface temperatures, even at night. Still

  7. Layered Thermohaline Convection in Hypersaline GeothermalSystems

    SciTech Connect

    Oldenburg, Curtis M.; Pruess, Karsten

    1997-01-05

    Thermohaline convection occurs in hypersaline geothermal systems due to thermal and salinity effects on liquid density. Because of its importance in oceanography, thermohaline convection in viscous liquids has received more attention than thermohaline convection in porous media. The fingered and layered convection patterns observed in viscous liquid thermohaline convection have been hypothesized to occur also in porous media. However, the extension of convective dynamics from viscous liquid systems to porous media systems is complicated by the presence of the solid matrix in porous media. The solid grains cause thermal retardation, hydrodynamic dispersion, and permeability effects. We present simulations of thermohaline convection in model systems based on the Salton Sea Geothermal System, California, that serve to point out the general dynamics of porous media thermohaline convection in the diffusive regime, and the effects of porosity and permeability, in particular. We use the TOUGH2 simulator with residual formulation and fully coupled solution technique for solving the strongly coupled equations governing thermohaline convection in porous media. We incorporate a model for brine density that takes into account the effects of NaCl and CaCl2. Simulations show that in forced convection, the increased pore velocity and thermal retardation in low-porosity regions enhances brine transport relative to heat transport. In thermohaline convection, the heat and brine transport are strongly coupled and enhanced transport of brine over heat cannot occur because buoyancy caused by heat and brine together drive the flow. Random permeability heterogeneity has a limited effect if the scale of flow is much larger than the scale of permeability heterogeneity. For the system studied here, layered thermohaline convection persists for more than one million years for a variety of initial conditions. Our simulations suggest that layered thermohaline convection is possible in

  8. Coupled reactive flow modeling with declining reactivity in fractured geothermal systems

    NASA Astrophysics Data System (ADS)

    Palguta, J.; Williams, C. F.; Ingebritsen, S.; Hickman, S.; Sonnenthal, E. L.

    2011-12-01

    mineral precipitation controls primary mineral dissolution. The two-dimensional models also allow us to consider the importance of diffusion in controlling reaction behavior. We conclude that mathematically linking reactivity loss to declining surface area may be a viable way to obtain more accurate predictions of the spatial and temporal changes of key geothermal system properties (e.g., permeability, mineral compositions, and solute concentrations) over extended periods of time. Our findings suggest that modeling approaches that do not incorporate a mechanism for rapid changes in reactive surface area may over predict the rate of fracture permeability decay. Consequently, this work also implies that some fraction of the increased permeability resulting from fracture formation and reactivation in tectonically active geothermal systems may be maintained over significant time intervals. Therefore, the models provide a potential framework for predicting the long-term behavior of natural geothermal systems.

  9. Thermal history of the Acoculco geothermal system, eastern Mexico: Insights from numerical modeling and radiocarbon dating

    NASA Astrophysics Data System (ADS)

    Canet, Carles; Trillaud, Frederic; Prol-Ledesma, Rosa María; González-Hernández, Galia; Peláez, Berenice; Hernández-Cruz, Berenice; Sánchez-Córdova, María M.

    2015-10-01

    Acoculco is a geothermal prospective area hosted by a volcanic caldera complex in the eastern Trans-Mexican Volcanic Belt. Surface manifestations are scarce and consist of gas discharges (CO2-rich) and acid-sulfate springs of low temperature, whereas hydrothermal explosive activity is profusely manifested by meter-scale craters and mounds of hydrothermal debris and breccias. Silicic alteration extends for several square kilometers around the zone with gas manifestations and explosive features, affecting surficial volcanic rocks, primarily tuffs and breccias. In the subsurface, an argillic alteration zone (ammonium illite) extends down to a depth of ∼ 600 m, and underneath it a propylitic zone (epidote-calcite-chlorite) occurs down to ∼ 1000 m. Thermal logs from an exploratory borehole (EAC-1, drilled in 1995 down to 1810 m) showed a conductive heat transfer regime under high geothermal gradient (∼ 140 °C/1000 m). In contrast, the thermal profile established from temperatures of homogenization of fluid inclusions-measured on core samples from the same drill hole-suggests that convection occurred in the past through the upper ~ 1400 m of the geothermal system. A drop in permeability due to the precipitation of alteration minerals would have triggered the cessation of the convective heat transfer regime to give place to a conductive one. With the purpose of determining when the transition of heat transfer regime occurred, we developed a 1D model that simulates the time-depth distribution of temperature. According to our numerical simulations, this transition happened ca. 7000 years ago; this date is very recent compared to the lifespan of the geothermal system. In addition, radiocarbon chronology indicates that the hydrothermal explosive activity postdates the end of the convective heat transfer regime, having dated at least three explosive events, at 4867-5295, 1049-1417 and 543-709 y cal. BP. Therefore, hydrothermal explosions arise from the self-sealing of

  10. National Geothermal Data System: State Geological Survey Contributions to Date

    NASA Astrophysics Data System (ADS)

    Patten, K.; Allison, M. L.; Richard, S. M.; Clark, R.; Love, D.; Coleman, C.; Caudill, C.; Matti, J.; Musil, L.; Day, J.; Chen, G.

    2012-12-01

    In collaboration with the Association of American State Geologists the Arizona Geological Survey is leading the effort to bring legacy geothermal data to the U.S. Department of Energy's National Geothermal Data System (NGDS). NGDS is a national, sustainable, distributed, interoperable network of data and service (application) providers entering its final stages of development. Once completed the geothermal industry, the public, and policy makers will have access to consistent and reliable data, which in turn, reduces the amount of staff time devoted to finding, retrieving, integrating, and verifying information. With easier access to information, the high cost and risk of geothermal power projects (especially exploration drilling) is reduced. This presentation focuses on the scientific and data integration methodology as well as State Geological Survey contributions to date. The NGDS is built using the U.S. Geoscience Information Network (USGIN) data integration framework to promote interoperability across the Earth sciences community and with other emerging data integration and networking efforts. Core to the USGIN concept is that of data provenance; by allowing data providers to maintain and house their data. After concluding the second year of the project, we have nearly 800 datasets representing over 2 million data points from the state geological surveys. A new AASG specific search catalog based on popular internet search formats enables end users to more easily find and identify geothermal resources in a specific region. Sixteen states, including a consortium of Great Basin states, have initiated new field data collection for submission to the NGDS. The new field data includes data from at least 21 newly drilled thermal gradient holes in previously unexplored areas. Most of the datasets provided to the NGDS are being portrayed as Open Geospatial Consortium (OGC) Web Map Services (WMS) and Web Feature Services (WFS), meaning that the data is compatible with a

  11. Beneficial effects of groundwater entry into liquid-dominated geothermal systems

    SciTech Connect

    Lippmann, M.J. ); Truesdell, A.H. )

    1990-04-01

    In all active liquid-dominated geothermal systems there is continuous circulation of mass and transfer of heat, otherwise they would slowly cool and fade away. In the natural state these systems are in dynamic equilibrium with the surrounding colder groundwater aquifers. The ascending geothermal fluids cool conductively, boil, or mix with groundwaters, and ultimately may discharge at the surface as fumaroles or hot springs. With the start of fluid production and the lowering of reservoir pressure, the natural equilibrium is disrupted and cooler groundwater tends to enter the reservoir. Improperly constructed or damaged wells, and wells located near the margins of the geothermal system, exhibit temperature reductions (and possibly scaling from mixing of chemically distinct fluids) as the cooler-water moves into the reservoir. These negative effects, especially in peripheral wells are, however, compensated by the maintenance of reservoir pressure and a reduction in reservoir boiling that might result in mineral precipitation in the formation pores and fractures. The positive effect of cold groundwater entry on the behavior of liquid-dominated system is illustrated by using simple reservoir models. The simulation results show that even though groundwater influx into the reservoir causes cooling of fluids produced from wells located near the cold-water recharge area, it also reduces pressure drawdown and boiling in the exploited zone, and sweeps the heat stored in the reservoir rocks toward production wells, thus increasing the productive life of the wells and field. 9 refs.

  12. Geothermal pump down-hole energy regeneration system

    DOEpatents

    Matthews, Hugh B.

    1982-01-01

    Geothermal deep well energy extraction apparatus is provided of the general kind in which solute-bearing hot water is pumped to the earth's surface from a subterranean location by utilizing thermal energy extracted from the hot water for operating a turbine motor for driving an electrical power generator at the earth 3 s surface, the solute bearing water being returned into the earth by a reinjection well. Efficiency of operation of the total system is increased by an arrangement of coaxial conduits for greatly reducing the flow of heat from the rising brine into the rising exhaust of the down-well turbine motor.

  13. Long-term predictions of minewater geothermal systems heat resources

    NASA Astrophysics Data System (ADS)

    Harcout-Menou, Virginie; de ridder, fjo; laenen, ben; ferket, helga

    2014-05-01

    Abandoned underground mines usually flood due to the natural rise of the water table. In most cases the process is relatively slow giving the mine water time to equilibrate thermally with the the surrounding rock massif. Typical mine water temperature is too low to be used for direct heating, but is well suited to be combined with heat pumps. For example, heat extracted from the mine can be used during winter for space heating, while the process could be reversed during summer to provide space cooling. Altough not yet widely spread, the use of low temperature geothermal energy from abandoned mines has already been implemented in the Netherlands, Spain, USA, Germany and the UK. Reliable reservoir modelling is crucial to predict how geothermal minewater systems will react to predefined exploitation schemes and to define the energy potential and development strategy of a large-scale geothermal - cold/heat storage mine water systems. However, most numerical reservoir modelling software are developed for typical environments, such as porous media (a.o. many codes developed for petroleum reservoirs or groundwater formations) and cannot be applied to mine systems. Indeed, mines are atypical environments that encompass different types of flow, namely porous media flow, fracture flow and open pipe flow usually described with different modelling codes. Ideally, 3D models accounting for the subsurface geometry, geology, hydrogeology, thermal aspects and flooding history of the mine as well as long-term effects of heat extraction should be used. A new modelling approach is proposed here to predict the long-term behaviour of Minewater geothermal systems in a reactive and reliable manner. The simulation method integrates concepts for heat and mass transport through various media (e.g., back-filled areas, fractured rock, fault zones). As a base, the standard software EPANET2 (Rossman 1999; 2000) was used. Additional equations for describing heat flow through the mine (both

  14. Geothermal tomorrow 2008

    SciTech Connect

    None, None

    2009-01-18

    Contributors from the Geothermal Technologies Program and the geothermal community highlight the current status and activities of the Program and the development of the global resource of geothermal energy.

  15. Geothermal progress monitor report No. 6

    SciTech Connect

    Not Available

    1982-06-01

    Geothermal Progress Monitor Report No. 6 presents a state-by-state summary of the status of geothermal leasing, exploration, and development in major physiographic regions where geothermal resource potential has been identified. Recent state-specific activities are reported at the end of each state status report, while recent activities of a more general nature are summarized briefly in Part II of the report. A list of recent publications of potential interest to the geothermal community and a directory of contributors to the geothermal progress monitoring system are also included.

  16. Parametric Analysis of the Factors Controlling the Costs of Sedimentary Geothermal Systems - Preliminary Results (Poster)

    SciTech Connect

    Augustine, C.

    2013-10-01

    Parametric analysis of the factors controlling the costs of sedimentary geothermal systems was carried out using a modified version of the Geothermal Electricity Technology Evaluation Model (GETEM). The sedimentary system modeled assumed production from and injection into a single sedimentary formation.

  17. Proceedings of a Topical Meeting On Small Scale Geothermal Power Plants and Geothermal Power Plant Projects

    SciTech Connect

    1986-02-12

    These proceedings describe the workshop of the Topical Meeting on Small Scale Geothermal Power Plants and Geothermal Power Plant Projects. The projects covered include binary power plants, rotary separator, screw expander power plants, modular wellhead power plants, inflow turbines, and the EPRI hybrid power system. Active projects versus geothermal power projects were described. In addition, a simple approach to estimating effects of fluid deliverability on geothermal power cost is described starting on page 119. (DJE-2005)

  18. A New Concept for Geothermal Energy Extraction: The Radiator - Enhanced Geothermal System

    NASA Astrophysics Data System (ADS)

    Hilpert, M.; Geiser, P.; Marsh, B. D.; Malin, P. E.; Moore, S.

    2014-12-01

    Enhanced Geothermal Systems (EGS) in hot dry rock frequently underperform or fail due to insufficient reservoir characterization and poorly controlled permeability stimulation. Our new EGS design is based on the concept of a cooling radiator of an internal combustion engine, which we call the Radiator EGS (RAD-EGS). Within a hot sedimentary aquifer, we propose to construct vertically extensive heat exchanger vanes, which consist of rubblized zones of high permeability and which emulate a hydrothermal system. A "crows-foot" lateral drilling pattern at multiple levels is used to form a vertical array that includes S1 and Shmax. To create the radiator, we propose to use propellant fracing. System cool-down is delayed by regional background flow and induced upward flow of the coolant which initially heats the rock. Tomographic Fracture Imaging is used to image and control the permeability field changes. Preliminary heat transfer calculations suggest that the RAD-EGS will allow for commercial electricity production for at least several tens of years.

  19. Code Comparison Study Fosters Confidence in the Numerical Simulation of Enhanced Geothermal Systems

    SciTech Connect

    White, Mark D.; Phillips, Benjamin R.

    2015-01-26

    Numerical simulation has become a standard analytical tool for scientists and engineers to evaluate the potential and performance of enhanced geothermal systems. A variety of numerical simulators developed by industry, universities, and national laboratories are currently available and being applied to better understand enhanced geothermal systems at the field scale. To yield credible predictions and be of value to site operators, numerical simulators must be able to accurately represent the complex coupled processes induced by producing geothermal systems, such as fracture aperture changes due to thermal stimulation, fracture shear displacement with fluid injection, rate of thermal depletion of reservoir rocks, and permeability alteration with mineral precipitation or dissolution. A suite of numerical simulators was exercised on a series of test problems that considered coupled thermal, hydraulic, geomechanical, and geochemical (THMC) processes. Problems were selected and designed to isolate selected coupled processes, to be executed on workstation class computers, and have simple but illustrative metrics for result comparisons. This paper summarizes the initial suite of seven benchmark problems, describes the code comparison activities, provides example results for problems and documents the capabilities of currently available numerical simulation codes to represent coupled processes that occur during the production of geothermal resources. Code comparisons described in this paper use the ISO (International Organization for Standardization) standard ISO-13538 for proficiency testing of numerical simulators. This approach was adopted for a recent code comparison study within the radiation transfer-modeling field of atmospheric sciences, which was focused on canopy reflectance models. This standard specifies statistical methods for analyzing laboratory data from proficiency testing schemes to demonstrate that the measurement results do not exhibit evidence of an

  20. Development of geothermal logging systems in the United States

    SciTech Connect

    Lysne, P.

    1994-04-01

    Logging technologies developed for hydrocarbon resource evaluation have not migrated into geothermal applications even though data so obtained would strengthen reservoir characterization efforts. Two causative issues have impeded progress: (1) there is a general lack of vetted, high-temperature instrumentation, and (2) the interpretation of log data generated in a geothermal formation is in its infancy. Memory-logging tools provide a path around the first obstacle by providing quality data at a low cost. These tools feature on-board computers that process and store data, and newer systems may be programmed to make decisions. Since memory tools are completely self-contained, they are readily deployed using the slick line found on most drilling locations. They have proven to be rugged, and a minimum training program is required for operator personnel. Present tools measure properties such as temperature and pressure, and the development of noise, deviation, and fluid conductivity logs based on existing hardware is relatively easy. A more complex geochemical tool aimed at a quantitative analysis of (potassium, uranium and thorium) is in the calibration phase, and it is expandable into all nuclear measurements common in the hydrocarbon industry. A fluid sampling tool is in the design phase. All tools are designed for operation at conditions exceeding 400 C, and for deployment in the slim holes produced by mining-coring operations. Partnerships are being formed between the geothermal industry and scientific drilling programs to define and develop inversion algorithms relating raw tool data to more pertinent information. These cooperative efforts depend upon quality guidelines such as those under development within the international Ocean Drilling Program.

  1. Geologic and preliminary reservoir data on the Los Humeros Geothermal System, Puebla, Mexico

    SciTech Connect

    Ferriz, H.

    1982-01-01

    Exploratory drilling has confirmed the existence of a geothermal system in the Los Humeros volcanic center, located 180 km east of Mexico City. Volcanic activity in the area began with the eruption of andesites, followed by two major caldera-forming pyroclastic eruptions. The younger Los Potreros caldera is nested inside the older Los Humeros caldera. At later stages, basaltic andesite, dacite, and olivine basalt lavas erupted along the ring-fracture zones of both calderas. Geologic interpretation of structural, geophysical, and drilling data suggests that: (1) the water-dominated geothermal reservoir is hosted by the earliest andesitic volcanic pile, is bounded by the ring-fracture zone of the Los Potreros caldera, and is capped by the products of the oldest caldera-forming eruption; (2) permeability within the andesitic pile is provided by faults and fractures related to intracaldera uplift; (3) the geothermal system has potential for a large influx of meteoric water through portions of the ring-fracture zones of both calderas; and (4) volcanic centers with similar magmatic and structural conditions can be found in the eastern Cascades, USA.

  2. Three-Dimensional Geologic Characterization of Geothermal Systems: Astor Pass, Nevada, USA

    SciTech Connect

    Siler, Drew L; Mayhew, Brett; Faulds, James E

    2012-09-30

    Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to geothermal circulation is crucial in order to both mitigate the costs of geothermal exploration (especially drilling) and to identify blind geothermal systems (no surface expression). Astor Pass, Nevada, one such blind geothermal system, lies near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present at Astor Pass. Previous studies identified a blind geothermal system controlled by the intersection of northwest-striking dextral and north-northwest-striking normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting significantly higher maximum temperatures. Additional data, including reprocessed 2D seismic data and petrologic analysis of well cuttings, were integrated with existing and reinterpreted geologic maps and cross-sections to aid construction of a 3D geologic model. This comprehensive 3D integration of multiple data sets allows characterization of the structural setting of the Astor Pass blind geothermal system at a level of detail beyond what independent data interpretation can provide. Our analysis indicates that the blind geothermal system is controlled by two north- to northwest-plunging fault intersections.

  3. Assessing the role of ancient and active geothermal systems in oil-reservoir evolution in the eastern Basin and Range province, western USA. Annual progress report, June 1, 1992--May 31, 1993

    SciTech Connect

    Hulen, J.B.

    1993-07-01

    Results of our research on the oil fields of the Basin and Range province of the western USA continue to support the following concept: Convecting, moderate-temperature geothermal systems in this region have fostered and in some cases critically influenced the generation, migration, and entrapment of oil. At one Basin-Range field (Grant Canyon), oil-bearing and aqueous fluid inclusions in late-stage hydrothermal quartz were entrapped at temperatures comparable to those now prevailing at reservoir depths (120--130{degrees}C); apparent salinities of the aqueous varieties match closely the actual salinity of the modern, dilute oil-field waters. The inclusion-bearing quartz has the oxygen-isotopic signature for precipitation of the mineral at contemporary temperatures from modern reservoir waters. Measured and fluid-inclusion temperatures define near-coincident isothermal profiles through the oil-reservoir interval, a phenomenon suggesting ongoing heat and mass transfer. These findings are consistent with a model whereby a still-active, convectively circulating, meteoric-hydrothermal system: (1) enhanced porosity in the reservoir rock through dissolution of carbonate; (2) hydrothermally sealed reservoir margins; (3) transported oil to the reservoirs from a deep source of unknown size and configuration; and (4) possibly accelerated source-rock maturation through an increase in the local thermal budget. Grant Canyon and other Basin-Range oil fields are similar to the oil-bearing, Carlin-type, sediment-hosted, disseminated gold deposits of the nearby Alligator Ridge district. The oil fields could represent either weakly mineralized analogues of these deposits, or perhaps an incipient phase in their evolution.

  4. Enhanced Geothermal Systems (EGS) well construction technology evaluation report.

    SciTech Connect

    Capuano, Louis, Jr.; Huh, Michael; Swanson, Robert; Raymond, David Wayne; Finger, John Travis; Mansure, Arthur James; Polsky, Yarom; Knudsen, Steven Dell

    2008-12-01

    Electricity production from geothermal resources is currently based on the exploitation of hydrothermal reservoirs. Hydrothermal reservoirs possess three ingredients critical to present day commercial extraction of subsurface heat: high temperature, in-situ fluid and high permeability. Relative to the total subsurface heat resource available, hydrothermal resources are geographically and quantitatively limited. A 2006 DOE sponsored study led by MIT entitled 'The Future of Geothermal Energy' estimates the thermal resource underlying the United States at depths between 3 km and 10 km to be on the order of 14 million EJ. For comparison purposes, total U.S. energy consumption in 2005 was 100 EJ. The overwhelming majority of this resource is present in geological formations which lack either in-situ fluid, permeability or both. Economical extraction of the heat in non-hydrothermal situations is termed Enhanced or Engineered Geothermal Systems (EGS). The technologies and processes required for EGS are currently in a developmental stage. Accessing the vast thermal resource between 3 km and 10 km in particular requires a significant extension of current hydrothermal practice, where wells rarely reach 3 km in depth. This report provides an assessment of well construction technology for EGS with two primary objectives: (1) Determining the ability of existing technologies to develop EGS wells. (2) Identifying critical well construction research lines and development technologies that are likely to enhance prospects for EGS viability and improve overall economics. Towards these ends, a methodology is followed in which a case study is developed to systematically and quantitatively evaluate EGS well construction technology needs. A baseline EGS well specification is first formulated. The steps, tasks and tools involved in the construction of this prospective baseline EGS well are then explicitly defined by a geothermal drilling contractor in terms of sequence, time and cost. A

  5. A geochemical reconnaissance of the Alid volcanic center and geothermal system, Danakil depression, Eritrea

    USGS Publications Warehouse

    Lowenstern, J. B.; Janik, C.J.; Fournier, R.O.; Tesfai, T.; Duffield, W.A.; Clynne, M.A.; Smith, James G.; Woldegiorgis, L.; Weldemariam, K.; Kahsai, G.

    1999-01-01

    Geological and geochemical studies indicate that a high-temperature geothermal system underlies the Alid volcanic center in the northern Danakil depression of Eritrea. Alid is a very late-Pleistocene structural dome formed by shallow intrusion of rhyolitic magma, some of which vented as lavas and pyroclastic flows. Fumaroles and boiling pools distributed widely over an area of ~10 km2 on the northern half of Alid suggest that an active hydrothermal system underlies much of that part of the mountain. Geothermometers indicate that the fumarolic gases are derived from a geothermal system with temperatures >225??C. The isotopic composition of condensed fumarolic steam is consistent with these temperatures and implies that the source water is derived primarily from either lowland meteoric waters or fossil Red Sea water, or both. Some gases vented from the system (CO2, H2S and He) are largely magmatic in origin. Permeability beneath the volcanic center may be high, given the amount of intrusion-related deformation and the active normal faulting within the Danakil depression.Geological and geochemical studies indicate that a high-temperature geothermal system underlies the Alid volcanic center in the northern Danakil depression of Eritrea. Alid is a very late-Pleistocene structural dome formed by shallow intrusion of rhyolitic magma, some of which vented as lavas and pyroclastic flows. Fumaroles and boiling pools distributed widely over an area of approx. 10 km2 on the northern half of Alid suggest that an active hydrothermal system underlies much of that part of the mountain. Geothermometers indicate that the fumarolic gases are derived from a geothermal system with temperatures >225??C. The isotopic composition of condensed fumarolic steam is consistent with these temperatures and implies that the source water is derived primarily from either lowland meteoric waters or fossil Red Sea water, or both. Some gases vented from the system (CO2, H2S and He) are largely

  6. A novel heat flux study of a geothermally active lake - Lake Rotomahana, New Zealand

    NASA Astrophysics Data System (ADS)

    Tivey, Maurice A.; de Ronde, Cornel E. J.; Tontini, Fabio Caratori; Walker, Sharon L.; Fornari, Daniel J.

    2016-03-01

    A new technique for measuring conductive heat flux in a lake was adapted from the marine environment to allow for multiple measurements to be made in areas where bottom sediment cover is sparse, or even absent. This thermal blanket technique, pioneered in the deep ocean for use in volcanic mid-ocean rift environments, was recently used in the geothermally active Lake Rotomahana, New Zealand. Heat flow from the lake floor propagates into the 0.5 m diameter blanket and establishes a thermal gradient across the known blanket thickness and thereby provides an estimate of the conductive heat flux of the underlying terrain. This approach allows conductive heat flux to be measured over a spatially dense set of stations in a relatively short period of time. We used 10 blankets and deployed them for 1 day each to complete 110 stations over an 11-day program in the 6 × 3 km lake. Results show that Lake Rotomahana has a total conductive heat flux of about 47 MW averaging 6 W/m2 over the geothermally active lake. The western half of the lake has two main areas of high heat flux; 1) a high heat flux area averaging 21.3 W/m2 along the western shoreline, which is likely the location of the pre-existing geothermal system that fed the famous Pink Terraces, mostly destroyed during the 1886 eruption 2) a region southwest of Patiti Island with a heat flux averaging 13.1 W/m2 that appears to be related to the explosive rift that formed the lake in the 1886 Tarawera eruption. A small rise in bottom water temperature over the survey period of 0.01 °C/day suggests the total thermal output of the lake is ~ 112-132 MW and when compared to the conductive heat output suggests that 18-42% of the total thermal energy is by conductive heat transfer.

  7. Electronic Submersible Pump (ESP) Technology and Limitations with Respect to Geothermal Systems (Fact Sheet)

    SciTech Connect

    Not Available

    2014-09-01

    The current state of geothermal technology has limitations that hinder the expansion of utility scale power. One limitation that has been discussed by the current industry is the limitation of Electric Submersible Pump (ESP) technology. With the exception of a few geothermal fields artificial lift technology is dominated by line shaft pump (LSP) technology. LSP's utilize a pump near or below reservoir depth, which is attached to a power shaft that is attached to a motor above ground. The primary difference between an LSP and an ESP is that an ESP motor is attached directly to the pump which eliminates the power shaft. This configuration requires that the motor is submersed in the geothermal resource. ESP technology is widely used in oil production. However, the operating conditions in an oil field vary significantly from a geothermal system. One of the most notable differences when discussing artificial lift is that geothermal systems operate at significantly higher flow rates and with the potential addition of Enhanced Geothermal Systems (EGS) even greater depths. The depths and flow rates associated with geothermal systems require extreme horsepower ratings. Geothermal systems also operate in a variety of conditions including but not limited to; high temperature, high salinity, high concentrations of total dissolved solids (TDS), and non-condensable gases.

  8. Alteration mineralogy of the Dixie Valley geothermal system, Nevada

    SciTech Connect

    Lutz, S.J.; Moore, J.N.; Benoit, D.

    1996-12-31

    Petrographic studies along the Stillwater fault zone in Dixie Valley, Nevada document a variety of overlapping alteration assemblages that represent different physical and chemical conditions. At depth in the northern portion of the Dixie Valley geothermal field, wairakite, illite-smectite, and chalcedonic quartz are present in the hanging wall where measured, static and flowing temperatures are close to 248{degrees}C. Although the presence of wairakite is consistent with the observed temperatures, both the illite-smectite and chalcedonic quartz suggest lower temperature conditions. In outcrop, samples from the footwall of the Stillwater fault contain quartz, kaolin, smectite, dolomite, biotite, and epidote. Crosscutting relationships indicate that quartz and kaolin postdate formation of older biotite and epidote veins. The superposition of lower temperature assemblages (kaolin, dolomite, smectite) upon higher temperature minerals (biotite, epidote) characterizes the alteration in the footwall, whereas, the superposition of higher temperature minerals (wairakite) upon lower temperature phases (chalcedonic quartz, illite-smectite) is characteristic of the alteration in the geothermal reservoir within the hanging wall. This retrograde and prograde progression of alteration should be expected along this active normal fault as the footwall is uplifted and exhumed through time, and simultaneously, the hanging wall is down dropped.

  9. Modeling studies of geothermal systems with a free water surface

    SciTech Connect

    Bodvarsson, G.S.; Pruess, K.

    1983-12-01

    A numerical simulator was developed for the modeling of air-steam-water systems. The simulator was applied to various problems involving injection into or production from a geothermal reservoir in hydraulic communication with a shallow free-surface aquifer. First, a one-dimensional column problem is considered and the water level movement during exploitation is studied using different capillary pressure functions. Second, a two-dimensional radial model is used to study and compare reservoir depletion for cases with and without a free-surface aquifer. Finally, the contamination of a shallow free-surface aquifer due to cold water injection is investigated. The primary aim of these studies is to obtain an understanding of the response of a reservoir in hydraulic communication with a unconfined aquifer during exploitation or injection and to determine under which circumstances conventional modeling techniques (fully saturated systems) can be applied to such systems.

  10. Marketing the Klamath Falls Geothermal District Heating system

    SciTech Connect

    Rafferty, K.

    1993-06-01

    The new marketing strategy for the Klamath Falls system has concentrated on offering the customer an attractive and easy to understand rate structure, reduced retrofit cost and complexity for his building along with an attractive package of financing and tax credits. Initial retrofit costs and life-cycle cost analysis have been conducted on 22 buildings to date. For some, the retrofit costs are simply too high for the conversion to make sense at current geothermal rates. For many, however, the prospects are good. At this writing, two new customers are now connected and operating with 5 to 8 more buildings committed to connect this construction season after line extensions are completed. This represents nearly a 60% increase in the number of buildings connected to the system and a 40% increase in system revenue.

  11. Hydrothermal fluids circulation and travertine deposition in an active tectonic setting: Insights from the Kamara geothermal area (western Anatolia, Turkey)

    NASA Astrophysics Data System (ADS)

    Brogi, Andrea; Alçiçek, M. Cihat; Yalçıner, Cahit Çağlar; Capezzuoli, Enrico; Liotta, Domenico; Meccheri, Marco; Rimondi, Valentina; Ruggieri, Giovanni; Gandin, Anna; Boschi, Chiara; Büyüksaraç, Aydin; Alçiçek, Hülya; Bülbül, Ali; Baykara, Mehmet Oruç; Shen, Chuan-Chou

    2016-06-01

    Coexistence of thermal springs, travertine deposits and tectonic activity is a recurring feature for most geothermal areas. Although such a certainty, their relationships are debated mainly addressing on the role of the tectonic activity in triggering and controlling fluids flow and travertine deposition. In this paper, we present the results of an integrated study carried out in a geothermal area located in western Anatolia (Turkey), nearby the well-known Pamukkale area (Denizli Basin). Our study focused on the relationships among hydrothermal fluids circulation, travertine deposition and tectonic activity, with particular emphasis on the role of faults in controlling fluids upwelling, thermal springs location and deposition of travertine masses. New field mapping and structural/kinematics analyses allowed us to recognize two main faults systems (NW- and NE-trending), framed in the Neogene-Quaternary extensional tectonic evolution of western Anatolia. A geo-radar (GPR) prospection was also provided in a key-area, permitting us to reconstruct a buried fault zone and its relationships with the development of a fissure-ridge travertine deposit (Kamara fissure-ridge). The integration among structural and geophysical studies, fluids inclusion, geochemical, isotopic data and 230 Th/238 U radiometric age determination on travertine deposits, depict the characteristics of the geothermal fluids and their pathway, up to the surface. Hydrological and seismological data have been also taken in account to investigate the relation between local seismicity and fluid upwelling. As a main conclusion we found strict relationships among tectonic activity, earthquakes occurrence, and variation of the physical/chemical features of the hydrothermal fluids, presently exploited at depth, or flowing out in thermal springs. In the same way, we underline the tectonic role in controlling the travertine deposition, making travertine (mainly banded travertine) a useful proxy to reconstruct the

  12. Other geothermal space-heating system in Elko, Nevada

    SciTech Connect

    Bugenig, D.C.; Scolari, D.; Vietti, J.

    1987-08-01

    In February 1985, the Elko County School District completed a 1971-ft deep geothermal well at the site of the Elko Junior High School, Elko, Nevada. Aquifer stress test results indicated that the well could sustain artesian flows of as much as 325 gal/min of 190/sup 0/F water. Because the productivity of the well, up to 15 x 10/sup 6/ Btu/hr, far exceeded the heating demand of the junior high school, a district space heating scheme was conceived to heat additional school-district facilities, a hospital, convention center, municipal swimming pool, and city offices. Estimated savings to the public entities involved and, ultimately, the taxpayers in Elko were projected at $285,000 annually. Approximately one mile of distribution lines were laid and 13 buildings were retrofitted to geothermal heating in time for the 1986-1987 heating season. The system is the second for Elko, the first being the Elko Heat Company that serves commercial users in the downtown area.

  13. Boron isotope variations in geothermal systems on Java, Indonesia

    NASA Astrophysics Data System (ADS)

    Purnomo, Budi Joko; Pichler, Thomas; You, Chen-Feng

    2016-02-01

    This paper presents δ11B data for hot springs, hot acid crater lakes, geothermal brines and a steam vent from Java, Indonesia. The processes that produce a large range of the δ11B values were investigated, including the possible input of seawater as well as the contrast δ11B compositions of acid sulfate and acid chloride crater lakes. The δ11B values of hot springs ranged from - 2.4 to + 28.7‰ and acid crater lakes ranged from + 0.6 to + 34.9‰. The δ11B and Cl/B values in waters from the Parangtritis and Krakal geothermal systems confirmed seawater input. The δ11B values of acid sulfate crater lakes ranged from + 5.5 to + 34.9‰ and were higher than the δ11B of + 0.6‰ of the acid chloride crater lake. The heavier δ11B in the acid sulfate crater lakes was caused by a combination of vapor phase addition and further enrichment due to evaporation and B adsorption onto clay minerals. In contrast, the light δ11B of the acid chloride crater lake was a result of acid water-rocks interaction. The correlations of δ11B composition with δ18O and δ2H indicated that the B isotope corresponded to their groundwater mixing sources, but not for J21 (Segaran) and J48 (Cikundul) that underwent 11B isotope enrichment by B adsorption into minerals.

  14. Gravity and magnetic features and their relationship to the geothermal system in southwestern South Dakota

    SciTech Connect

    Hildenbrand, T.G.; Kucks, R.P.

    1981-01-01

    An attempt is made to determine the sources that are responsible for producing geothermal anomalies observed within the southern Black Hills region. Lithologic and structural boundaries residing in the upper crust and their relationship to the geothermal system are discussed. A regional gravity survey was supplemented by a regional aeromagnetic survey.

  15. Geobotanical characterization of a geothermal system using hyperspectral imagery: Long Valley Caldera, CA

    SciTech Connect

    Carter, M R; Cochran, S A; Martini, B A; Pickles, W L; Potts, D C; Priest, R E; Silver, E A; Wayne, B A; White, W T

    1998-12-01

    We have analyzed hyperspectral Airborne Visible-Infrared Imaging System (AVIRIS) imagery taken in September of 1992 in Long Valley Caldera, CA, a geothermally active region expressed surficially by hot springs and fumaroles. Geological and vegetation mapping are attempted through spectral classification of imagery. Particular hot spring areas in the caldera are targeted for analysis. The data is analyzed for unique geobotanical patterns in the vicinity of hot springs as well as gross identification of dominant plant and mineral species. Spectra used for the classifications come from a vegetation spectral library created for plant species found to be associated with geothermal processes. This library takes into account the seasonality of vegetation by including spectra for species on a monthly basis. Geological spectra are taken from JPL and USGS mineral libraries. Preliminary classifications of hot spring areas indicate some success in mineral identification and less successful vegetation species identification. The small spatial extent of individual plants demands either sub-pixel analysis or increased spatial resolution of imagery. Future work will also include preliminary analysis of a hyperspectral thermal imagery dataset and a multitemporal air photo dataset. The combination of these remotely sensed datasets for Long Valley will yield a valuable product for geothermal exploration efforts in other regions.

  16. Screening for heat transport by groundwater in closed geothermal systems.

    PubMed

    Ferguson, Grant

    2015-01-01

    Heat transfer due to groundwater flow can significantly affect closed geothermal systems. Here, a screening method is developed, based on Peclet numbers for these systems and Darcy's law. Conduction-only conditions should not be expected where specific discharges exceed 10(-8)  m/s. Constraints on hydraulic gradients allow for preliminary screening for advection based on rock or soil types. Identification of materials with very low hydraulic conductivity, such as shale and intact igneous and metamorphic rock, allow for analysis with considering conduction only. Variability in known hydraulic conductivity allows for the possibility of advection in most other rocks and soil types. Further screening relies on refinement of estimates of hydraulic gradients and hydraulic conductivity through site investigations and modeling until the presence or absence of conduction can be confirmed.

  17. Screening for heat transport by groundwater in closed geothermal systems.

    PubMed

    Ferguson, Grant

    2015-01-01

    Heat transfer due to groundwater flow can significantly affect closed geothermal systems. Here, a screening method is developed, based on Peclet numbers for these systems and Darcy's law. Conduction-only conditions should not be expected where specific discharges exceed 10(-8)  m/s. Constraints on hydraulic gradients allow for preliminary screening for advection based on rock or soil types. Identification of materials with very low hydraulic conductivity, such as shale and intact igneous and metamorphic rock, allow for analysis with considering conduction only. Variability in known hydraulic conductivity allows for the possibility of advection in most other rocks and soil types. Further screening relies on refinement of estimates of hydraulic gradients and hydraulic conductivity through site investigations and modeling until the presence or absence of conduction can be confirmed. PMID:24438345

  18. Phase relations and adiabats in boiling seafloor geothermal systems

    USGS Publications Warehouse

    Bischoff, J.L.; Pitzer, Kenneth S.

    1985-01-01

    Observations of large salinity variations and vent temperatures in the range of 380-400??C suggest that boiling or two-phase separation may be occurring in some seafloor geothermal systems. Consideration of flow rates and the relatively small differences in density between vapors and liquids at the supercritical pressures at depth in these systems suggests that boiling is occurring under closed-system conditions. Salinity and temperature of boiling vents can be used to estimate the pressure-temperature point in the subsurface at which liquid seawater first reached the two-phase boundary. Data are reviewed to construct phase diagrams of coexisting brines and vapors in the two-phase region at pressures corresponding to those of the seafloor geothermal systems. A method is developed for calculating the enthalpy and entropy of the coexisting mixtures, and results are used to construct adiabats from the seafloor to the P-T two-phase boundary. Results for seafloor vents discharging at 2300 m below sea level indicate that a 385??C vent is composed of a brine (7% NaCl equivalent) in equilibrium with a vapor (0.1% NaCl). Brine constitutes 45% by weight of the mixture, and the fluid first boiled at approximately 1 km below the seafloor at 415??C, 330 bar. A 400??C vent is primarily vapor (88 wt.%, 0.044% NaCl) with a small amount of brine (26% NaCl) and first boiled at 2.9 km below the seafloor at 500??C, 520 bar. These results show that adiabatic decompression in the two-phase region results in dramatic cooling of the fluid mixture when there is a large fraction of vapor. ?? 1985.

  19. Thermal and chemical evolution of The Geysers geothermal system, California

    SciTech Connect

    Moore, J.N.

    1992-01-01

    Fluid inclusions and mineral assemblages provide a reward of the thermal and chemical changes that occurred during the evolution of The Geysers geothermal system. The data document the presence of an extensive liquid dominated geothermal system that developed in response to felsite intrusion and its evolution to a vapor-dominated regime. Temperatures within the early liquid-dominated system ranged from 175 C at a distance of 7200 feet from the felsite to more than 350 C near the contact while salinities varied from 5 equivalent weight percent NaCl (at a distance of 5500 feet) to more than 26 weight percent NaCl. As temperatures around the felsite declined, the liquid-dominated system collapsed upon itself. Downward migration of the low salinity waters resulted in dilution of the fluids present in regions now occupied by the caprock and normal vapor-dominated reservoir. In contrast, dilution was minor in rocks now hosting the high-temperature vapor-dominated reservoir. This suggests that low permeabilities are the primary reason for the development of the high-temperature reservoir. Boiling within the caprock produced late-stage veins of calcite and quartz. As the fluid boiled off, condensate was trapped as low salinity fluid inclusions. Within the main body of the reservoir, a liquid phase with salinities of up to 7 equivalent weight percent NaCl persisted to temperatures between 250 and 270 C. However, except for the presence of vapor-rich inclusions, little evidence of boiling within the reservoir rocks was preserved.

  20. Geochemical exploration of a promissory Enhanced Geothermal System (EGS): the Acoculco caldera, Mexico.

    NASA Astrophysics Data System (ADS)

    Peiffer, Loic; Romero, Ruben Bernard; Pérez-Zarate, Daniel; Guevara, Mirna; Santoyo Gutiérrez, Edgar

    2014-05-01

    The Acoculco caldera (Puebla, Mexico) has been identified by the Mexican Federal Electricity Company (in Spanish 'Comisión Federal de Electricidad', CFE) as a potential Enhanced Geothermal System (EGS) candidate. Two exploration wells were drilled and promising temperatures of ~300° C have been measured at a depth of 2000 m with a geothermal gradient of 11oC/100m, which is three times higher than the baseline gradient measured within the Trans-Mexican Volcanic Belt. As usually observed in Hot Dry Rock systems, thermal manifestations in surface are scarce and consist in low-temperature bubbling springs and soil degassing. The goals of this study were to identify the origin of these fluids, to estimate the soil degassing rate and to explore new areas for a future detailed exploration and drilling activities. Water and gas samples were collected for chemical and isotopic analysis (δ18O, δD, 3He/4He, 13C, 15N) and a multi-gas (CO2, CH4, H2S) soil survey was carried out using the accumulation chamber method. Springs' compositions indicate a meteoric origin and the dissolution of CO2 and H2S-rich gases, while gas compositions reveal a MORB-type origin mixed with some arc-type contribution. Gas geothermometry results are similar to temperatures measured during well drilling (260° C-300° C). Amongst all measured CO2 fluxes, only 5% (mean: 5543 g m-2 day-1) show typical geothermal values, while the remaining fluxes are low and correspond to biogenic degassing (mean: 18 g m-2 day-1). The low degassing rate of the geothermal system is a consequence of the intense hydrothermal alteration observed in the upper 800 m of the system which acts as an impermeable caprock. Highest measured CO2 fluxes (above > 600 g m-2 day-1) have corresponding CH4/CO2 flux ratios similar to mass ratios of sampled gases, which suggest an advective fluid transport. To represent field conditions, a numerical model was also applied to simulate the migration of CO2 towards the surface through a

  1. Warren Estates-Manzanita Estates Reno, Nevada residential geothermal district heating system

    SciTech Connect

    McKay, F.; McKay, G.; McKay, S.; Flynn, T.

    1995-12-31

    Warren Estates-Manzanita Estates is the largest privately-owned and operated residential geothermal district heating system in the State of Nevada. The system has operated for ten years and presently services 95 homes. Geothermal energy is used to heat homes, domestic water, spas, swimming pools, and greenhouses. Four homes have installed driveway deicing systems using geothermal energy. This paper briefly describes the geothermal resource, wells, system engineering, operation, applications, and economics. The accompanying posters illustrate the geothermal area, system design, and various applications. The resource is part of the Moana geothermal field, located in southwest Reno. Excluding the Warren-Manzanita Estates, the well-known Moana field supports nearly 300 geothermal wells that supply fluids to individual residences, several motels, a garden nursery, a few churches, and a municipal swimming pool. The Warren-Manzanita Estates is ideally suited for residential district space heating because the resource is shallow, moderate-temperature, and chemically benign. The primary reservoir rock is the Kate Peak andesite, a Tertiary volcanic lahar that has excellent permeability within the narrow fault zones that bisect the property. The Kate Peak formation is overlain by impermeable Tertiary lake sediments and alluvium. Two production wells, each about 240 m deep, are completed near the center of the residential development at the intersection of two fault zones. Geothermal fluids are pumped at a rate of 15 to 25 l/s (260-400 gpm) from one of two wells at a temperature of 95{degrees}C (202{degrees}F) to two flat-plate heat exchangers. The heat exchangers transfer energy from the geothermal fluids to a second fluid, much like a binary geothermal power plant.

  2. Federal Assistance Program Quarterly Project Progress Report. Geothermal Energy Program: Information Dissemination, Public Outreach, and Technical Analysis Activities. Reporting Period: January 1 - March 31, 2001 [Final report

    SciTech Connect

    Lund, John W.

    2002-03-22

    The final report of the accomplishments of the geothermal energy program: information dissemination, public outreach and technical analysis activities by the project team consisting of the Geo-Heat Center, Geothermal Resources Council, Geothermal Education Office, Geothermal Energy Association and the Washington State University Energy Program.

  3. High Fluoride and Geothermal Activities In Continental Rift Zones, Ethiopia

    NASA Astrophysics Data System (ADS)

    Weldesenbet, S. F.; Wohnlich, S.

    2012-12-01

    The Central Main Ethiopian Rift basin is a continental rift system characterized by volcano-tectonic depression endowed with huge geothermal resource and associated natural geochemical changes on groundwater quality. Chemical composition of groundwater in the study area showed a well defined trend along flow from the highland and escarpment to the rift floor aquifer. The low TDS (< 500mg/l) Ca-Mg-HCO3 dominated water at recharge area in the highlands and escarpments evolve progressively into Ca-Na-HCO3 and Na-Ca-HCO3 type waters along the rift ward groundwater flow paths. These waters finally appear as moderate TDS (mean 960mg/l) Na-HCO3 type and as high TDS (> 1000 mg/l) Na-HCO3-Cl type in volcano-lacustrine aquifers of the rift floor. High concentrations of fluoride (up to 97.2 mg/l) and arsenic (up to 98μg/l) are recognized feature of groundwaters which occur mostly in the vicinity of the geothermal fields and the rift lakes in the basin. Fluoride and arsenic content of dry volcaniclastic sediments close to these areas are in the range 666-2586mg/kg and 10-13mg/kg respectively. The relationship between fluoride and calcium concentrations in groundwaters showed negative correlation. Near-equilibrium state attained between the mineral fluorite (CaF2) and the majority of fluoride-rich (>30mg/l) thermal groundwater and shallow cold groundwater. This indicated that the equilibrium condition control the high concentration of fluoride in the groundwaters. Whereas undersaturation state of fluorite in some relatively low-fluoride (<30mg/l) thermal waters indicated a dilution by cold waters. Laboratory batch leaching experiments showed that fast dissolution of fluoride from the sediment samples suddenly leached into the interacting water at the first one hour and then remain stable throughout the experiment. The concentrations of leached fluoride from the hot spring deposits, the lacustrine sediments, and the pyroclastic rock are usually low (1% of the total or less than

  4. Life-cycle analysis results of geothermal systems in comparison to other power systems.

    SciTech Connect

    Sullivan, J. L.; Clark, C. E.; Han, J.; Wang, M.; Energy Systems

    2010-10-11

    A life-cycle energy and greenhouse gas emissions analysis has been conducted with Argonne National Laboratory's expanded Greenhouse Gases, Regulated Emissions, and Energy Use in Transportation (GREET) model for geothermal power-generating technologies, including enhanced geothermal, hydrothermal flash, and hydrothermal binary technologies. As a basis of comparison, a similar analysis has been conducted for other power-generating systems, including coal, natural gas combined cycle, nuclear, hydroelectric, wind, photovoltaic, and biomass by expanding the GREET model to include power plant construction for these latter systems with literature data. In this way, the GREET model has been expanded to include plant construction, as well as the usual fuel production and consumption stages of power plant life cycles. For the plant construction phase, on a per-megawatt (MW) output basis, conventional power plants in general are found to require less steel and concrete than renewable power systems. With the exception of the concrete requirements for gravity dam hydroelectric, enhanced geothermal and hydrothermal binary used more of these materials per MW than other renewable power-generation systems. Energy and greenhouse gas (GHG) ratios for the infrastructure and other life-cycle stages have also been developed in this study per kilowatt-hour (kWh) of electricity output by taking into account both plant capacity and plant lifetime. Generally, energy burdens per energy output associated with plant infrastructure are higher for renewable systems than conventional ones. GHG emissions per kWh of electricity output for plant construction follow a similar trend. Although some of the renewable systems have GHG emissions during plant operation, they are much smaller than those emitted by fossil fuel thermoelectric systems. Binary geothermal systems have virtually insignificant GHG emissions compared to fossil systems. Taking into account plant construction and operation, the GREET

  5. Production diagnostics of geothermal wells by means of a computerized expert system

    SciTech Connect

    Arellano, Victor M.; Iglesias, Eduardo R.

    1992-01-01

    Diagnostic of production problems in geothermal wells is a complex inferential task, which requires considerable knowledge of its possible causes, careful assessment of (sometimes bewildering) multidisciplinary evidence, and, of course, enough experience. These characteristics make this task a good candidate for a computerized expert system. On this conviction, we have developed the first version of WELL-DR, an expert system for geothermal-well production diagnostics. Though still in a rapid stage of evolution, this expert system already provides a convenient and useful tool for geothermal field development, operation and management.

  6. Geothermal systems of the Mono Basin-Long Valley region, eastern California and western Nevada

    SciTech Connect

    Higgins, C.T.; Flynn, T.; Chapman, R.H.; Trexler, D.T.; Chase, G.W.; Bacon, C.F.; Ghusn, G. Jr.

    1985-01-01

    This report presents the results of a cooperative study of geothermal systems in the region from Aurora, Nevada, and Bridgeport, California, south to Long Valley, California, by the Division of Mines and Geology and the Division of Earth Sciences of the University of Nevada, Las Vegas. Magmatic and hydrothermal systems have been common in the Mono Basin-Long Valley region for the last 15 million years. The objectives of this study were to begin determination of the properties and interactions of these systems and to develop hypotheses on the locations of undiscovered, active systems in the region. Special emphasis was given to the regional relationships and controls of the systems. This study includes a Bouguer gravity map of the region, several gravity and magnetic profiles, a resistivity profile near Aurora, and a potassium-argon date on Mud Spring volcano, also near Aurora. New interpretations of the data collected are presented and relative ages and distributions of thermal fluids, gravity anomalies, depths to the pre-Cenozoic basement, structural controls of the geothermal systems, and the late Cenozoic tectonic-magmatic evolution of the region are discussed.

  7. Geopressured-geothermal well activities in Louisiana. Annual report, 1 January 1991--31 December 1991

    SciTech Connect

    John, C.J.

    1992-10-01

    Since September 1978, microseismic networks have operated continuously around US Department of Energy (DOE) geopressured-geothermal well sites to monitor any microearthquake activity in the well vicinity. Microseismic monitoring is necessary before flow testing at a well site to establish the level of local background seismicity. Once flow testing has begun, well development may affect ground elevations and/or may activate growth faults, which are characteristic of the coastal region of southern Louisiana and southeastern Texas where these geopressured-geothermal wells are located. The microseismic networks are designed to detest small-scale local earthquakes indicative of such fault activation. Even after flow testing has ceased, monitoring continues to assess any microearthquake activity delayed by the time dependence of stress migration within the earth. Current monitoring shows no microseismicity in the geopressured-geothermal prospect areas before, during, or after flow testing.

  8. Exploration drilling and reservoir model of the Platanares geothermal system, Honduras, Central America

    USGS Publications Warehouse

    Goff, F.; Goff, S.J.; Kelkar, S.; Shevenell, L.; Truesdell, A.H.; Musgrave, J.; Rufenacht, H.; Flores, W.

    1991-01-01

    Results of drilling, logging, and testing of three exploration core holes, combined with results of geologic and hydrogeochemical investigations, have been used to present a reservoir model of the Platanares geothermal system, Honduras. Geothermal fluids circulate at depths ??? 1.5 km in a region of active tectonism devoid of Quaternary volcanism. Large, artesian water entries of 160 to 165??C geothermal fluid in two core holes at 625 to 644 m and 460 to 635 m depth have maximum flow rates of roughly 355 and 560 l/min, respectively, which are equivalent to power outputs of about 3.1 and 5.1 MW(thermal). Dilute, alkali-chloride reservoir fluids (TDS ??? 1200 mg/kg) are produced from fractured Miocene andesite and Cretaceous to Eocene redbeds that are hydrothermally altered. Fracture permeabillity in producing horizons is locally greater than 1500 and bulk porosity is ??? 6%. A simple, fracture-dominated, volume-impedance model assuming turbulent flow indicates that the calculated reservoir storage capacity of each flowing hole is approximately 9.7 ?? 106 l/(kg cm-2), Tritium data indicate a mean residence time of 450 yr for water in the reservoir. Multiplying the natural fluid discharge rate by the mean residence time gives an estimated water volume of the Platanares system of ??? 0.78 km3. Downward continuation of a 139??C/km "conductive" gradient at a depth of 400 m in a third core hole implies that the depth to a 225??C source reservoir (predicted from chemical geothermometers) is at least 1.5 km. Uranium-thorium disequilibrium ages on calcite veins at the surface and in the core holes indicate that the present Platanares hydrothermal system has been active for the last 0.25 m.y. ?? 1991.

  9. High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems

    SciTech Connect

    Turnquist, Norman; Qi, Xuele; Raminosoa, Tsarafidy; Salas, Ken; Samudrala, Omprakash; Shah, Manoj; Van Dam, Jeremy; Yin, Weijun; Zia, Jalal

    2013-12-20

    This report summarizes the progress made during the April 01, 2010 – December 30, 2013 period under Cooperative Agreement DE-EE0002752 for the U.S. Department of Energy entitled “High-Temperature-High-Volume Lifting for Enhanced Geothermal Systems.” The overall objective of this program is to advance the technology for well fluids lifting systems to meet the foreseeable pressure, temperature, and longevity needs of the Enhanced Geothermal Systems (EGS) industry for the coming ten years. In this program, lifting system requirements for EGS wells were established via consultation with industry experts and site visits. A number of artificial lift technologies were evaluated with regard to their applicability to EGS applications; it was determined that a system based on electric submersible pump (ESP) technology was best suited to EGS. Technical barriers were identified and a component-level technology development program was undertaken to address each barrier, with the most challenging being the development of a power-dense, small diameter motor that can operate reliably in a 300°C environment for up to three years. Some of the targeted individual component technologies include permanent magnet motor construction, high-temperature insulation, dielectrics, bearings, seals, thrust washers, and pump impellers/diffusers. Advances were also made in thermal management of electric motors. In addition to the overall system design for a full-scale EGS application, a subscale prototype was designed and fabricated. Like the full-scale design, the subscale prototype features a novel “flow-through-the-bore” permanent magnet electric motor that combines the use of high temperature materials with an internal cooling scheme that limits peak internal temperatures to <330°C. While the full-scale high-volume multi-stage pump is designed to lift up to 80 kg/s of process water, the subscale prototype is based on a production design that can pump 20 kg/s and has been modified

  10. Coniform stromatolites from geothermal systems, North Island, New Zealand

    USGS Publications Warehouse

    Jones, B.; Renaut, R.W.; Rosen, Michael R.; Ansdell, K.M.

    2002-01-01

    Coniform stromatolites are found in several sites in the Tokaanu and Whakarewarewa geothermal areas of North Island, New Zealand. At Tokaanu, silicification of these stromatolites is taking place in Kirihoro, a shallow hot springfed pool. At Whakarewarewa, subfossil silicified coniform stromatolites are found on the floor of "Waikite Pool" on the discharge apron below Waikite Geyser, and in an old sinter succession at Te Anarata. The microbes in the coniform stromatolites from Tokaanu, Waikite Pool, and Te Anarata have been well preserved through rapid silicification. Nevertheless, subtle differences in the silicification style induced morphological variations that commonly mask or alter morphological features needed for identification of the microbes in terms of extant taxa. The coniform stromatolites in the New Zealand hotspring pools are distinctive because (1) they are formed of upward tapering (i.e., conical) columns, (2) neighboring columns commonly are linked by vertical sheets or bridges, (3) internally, they are formed of alternating high- and low-porosity laminae that have a conical vertical profile, and (4) Phormidium form more than 90% of the biota. As such, they are comparable to modern coniform mats and stromatolites found in the geothermal systems of Yellowstone National Park and ice-covered lakes in Antarctica. Formation of the coniform stromatolites is restricted to pools that are characterized by low current energy and a microflora that is dominated by Phormidium. These delicate and intricate stromatolites could not form in areas characterized by fast flowing water or a diverse microflora. Thus, it appears that the distribution of these distinctive stromatolites is controlled by biological constraints that are superimposed on environmental needs.

  11. Geothermal system at 21°N, East Pacific Rise: physical limits on geothermal fluid and role of adiabatic expansion

    USGS Publications Warehouse

    Bischoff, J.L.

    1980-01-01

    Pressure-volume-temperature relations for water at the depth of the magma chamber at 21°N on the East Pacific Rise suggest that the maximum subsurface temperature of the geothermal fluid is about 420°C. Both the chemistry of the discharging fluid and thermal balance considerations indicate that the effective water/rock ratios in the geothermal system are between 7 and 16. Such low ratios preclude effective metal transport at temperatures below 350°C, but metal solubilization at 400°C and above is effective even at such low ratios. It is proposed that the 420°C fluid ascends essentially adiabatically and in the process expands, cools, and precipitates metal sulfides within the upper few hundred meters of the sea floor and on the sea floor itself.

  12. National Geothermal Data System: Case Studies on Exploration and Development of Potential Geothermal Sites Through Distributed Data Sharing

    SciTech Connect

    Anderson, Arlene; Allison, Lee; Richard, Steve; Caudill-Daugherty, Christy; Patten, Kim

    2014-09-29

    The NGDS released version 1 of the system on April 30, 2014 using the US Geoscience Information Network (USGIN) as its data integration platform. NGDS supports the 2013 Open Data Policy, and as such, the launch was featured at the 2014 Energy Datapalooza. Currently, the NGDS features a comprehensive user interface for searching and accessing nearly 41,000 documents and more than 9 million data points shared by scores of data providers across the U.S. The NGDS supports distributed data sharing, permitting the data owners to maintain the raw data that is made available to the consumer. Researchers and industry have been utilizing the NGDS as a mechanism for promoting geothermal development across the country, from hydrothermal to ground source heat pump applications. Case studies in geothermal research and exploration from across the country are highlighted.

  13. Geothermal Energy.

    ERIC Educational Resources Information Center

    Nemzer, Marilyn; Page, Deborah

    This curriculum unit describes geothermal energy in the context of the world's energy needs. It addresses renewable and nonrenewable energy sources with an in-depth study of geothermal energy--its geology, its history, and its many uses. Included are integrated activities involving science, as well as math, social studies, and language arts.…

  14. Geothermal Prospector: Supporting Geothermal Analysis Through Spatial Data Visualization and Querying Tools

    SciTech Connect

    Getman, Daniel; Anderson, Arlene; Augustine, Chad

    2015-09-02

    Determining opportunities for geothermal energy can involve a significant investment in data collection and analysis. Analysts within a variety of industry and research domains collect and use these data; however, determining the existence and availability of data needed for a specific analysis activity can be challenging and represents one of the initial barriers to geothermal development [2]. This paper describes the motivating factors involved in designing and building the Geothermal Prospector application, how it can be used to reduce risks and costs related to geothermal exploration, and where it fits within the larger collection of tools that is the National Geothermal Data System (NGDS) [5].

  15. Importance of Hydrogeological Conditions on Open-loop Geothermal System

    NASA Astrophysics Data System (ADS)

    Park, D.; Bae, G.; Kim, S.; Lee, K.

    2013-12-01

    The open-loop geothermal system has been known as an eco-friendly, energy-saving, and cost-efficient alternative for the cooling and heating of buildings with directly using the relatively stable temperature of groundwater. Thus, hydrogeological properties of aquifer, such as hydraulic conductivity and storage, must be important in the system application. The study site is located near Han-river, Korea, and because of the well-developed alluvium it might be a typical site appropriate to this system requiring an amount of groundwater. In this study, the first objective of numerical experiments was to find the best distributions of pumping and injection wells suitable to the hydrogeological conditions of the site for the efficient and sustainable system operation. The aquifer has a gravel layer at 15m depth below the ground surface and the river and the agricultural field, which may be a potential contaminant source, are located at the west and east sides, respectively. Under the general conditions that the regional groundwater flows from the east to the river, the locally reversed well distribution, locating the pumping well at upgradient and the injection well at downgradient of the regional flow, was most sustainable. The gravel layer with high hydraulic conductivity caused a little drawdown despite of an amount of pumping and allowed to stably reinject the used groundwater in all the cases, but it provided a passage transferring the injected heat to the pumping well quickly, particularly in the cases locating the injection well at the upgradient. This thermal interference was more severe in the cases of the short distance between the wells. The high conductive layer is also a reason that the seasonal role conversion of wells for the aquifer thermal energy storage was ineffective in this site. Furthermore, the well distribution vertical to the regional groundwater flow was stable, but not best, and, thus, it may be a good choice in the conditions that the regional

  16. Design, fabrication, delivery, operation and maintenance of a geothermal power conversion system

    NASA Technical Reports Server (NTRS)

    1980-01-01

    The design, fabrication, delivery, operation and maintenance of an Hydrothermal Power Company 1250 KVA geothermal power conversion system using a helical screw expander as the prime mover is described. Hydrostatic and acceptance testing are discussed.

  17. National Geothermal Data System State Contributions by Data Type (Appendix A1-b)

    SciTech Connect

    Love, Diane

    2015-12-20

    Multipaged spreadsheet listing an inventory of data submissions to the State contributions to the National Geothermal Data System project by services, by state, by metadata compilations, metadata, and map count, including a summary of information.

  18. Method for inhibiting silica precipitation and scaling in geothermal flow systems

    DOEpatents

    Harrar, J.E.; Lorensen, L.E.; Locke, F.E.

    1980-06-13

    A method for inhibiting silica scaling and precipitation in geothermal flow systems by on-line injection of low concentrations of cationic nitrogen-containing compounds, particularly polymeric imines, polymeric amines, and quaternary ammonium compounds is described.

  19. Method for inhibiting silica precipitation and scaling in geothermal flow systems

    DOEpatents

    Harrar, Jackson E.; Lorensen, Lyman E.; Locke, Frank E.

    1982-01-01

    A method for inhibiting silica scaling and precipitation in geothermal flow systems by on-line injection of low concentrations of cationic nitrogen-containing compounds, particularly polymeric imines, polymeric amines, and quaternary ammonium compounds.

  20. Design and Development of Geothermal Cooling System for Composite Climatic Zone in India

    NASA Astrophysics Data System (ADS)

    Ralegaonkar, R.; Kamath, M. V.; Dakwale, V. A.

    2014-09-01

    The tropical climate buildings use about 70 % of operating energy for cooling of built environment. In composite climatic zone like Nagpur, Maharashtra, India several electro-mechanical cooling appliances viz., evaporative coolers, air conditioners, etc. are used. Application of geothermal cooling system is a very apt option for saving energy and reducing emission when compared to conventional cooling techniques. In the present work design methodology of geothermal cooling system is broadly elaborated and is applied to a case study of an educational building located in composite climate. The application of conventional and geothermal cooling systems is compared in terms of energy consumption. It is found that geothermal cooling system saves around 90 % of electricity as compared to air conditioner and 100 % of water as compared to evaporative coolers. This approach can further be extended for larger applications that will reduce consumption of energy and water in buildings.

  1. Federal Geothermal Research Program Update - Fiscal Year 2004

    SciTech Connect

    Patrick Laney

    2005-03-01

    The Department of Energy (DOE) and its predecessors have conducted research and development (R&D) in geothermal energy since 1971. The Geothermal Technologies Program (GTP) works in partnership with industry to establish geothermal energy as an economically competitive contributor to the U.S. energy supply. Geothermal energy production, a $1.5 billion a year industry, generates electricity or provides heat for direct use applications. The technologies developed by the Geothermal Technologies Program will provide the Nation with new sources of electricity that are highly reliable and cost competitive and do not add to America's air pollution or the emission of greenhouse gases. Geothermal electricity generation is not subject to fuel price volatility and supply disruptions from changes in global energy markets. Geothermal energy systems use a domestic and renewable source of energy. The Geothermal Technologies Program develops innovative technologies to find, access, and use the Nation's geothermal resources. These efforts include emphasis on Enhanced Geothermal Systems (EGS) with continued R&D on geophysical and geochemical exploration technologies, improved drilling systems, and more efficient heat exchangers and condensers. The Geothermal Technologies Program is balanced between short-term goals of greater interest to industry, and long-term goals of importance to national energy interests. The program's research and development activities are expected to increase the number of new domestic geothermal fields, increase the success rate of geothermal well drilling, and reduce the costs of constructing and operating geothermal power plants. These improvements will increase the quantity of economically viable geothermal resources, leading in turn to an increased number of geothermal power facilities serving more energy demand. These new geothermal projects will take advantage of geothermal resources in locations where development is not currently possible or

  2. Federal Geothermal Research Program Update Fiscal Year 2004

    SciTech Connect

    Not Available

    2005-03-01

    The Department of Energy (DOE) and its predecessors have conducted research and development (R&D) in geothermal energy since 1971. The Geothermal Technologies Program (GTP) works in partnership with industry to establish geothermal energy as an economically competitive contributor to the U.S. energy supply. Geothermal energy production, a $1.5 billion a year industry, generates electricity or provides heat for direct use applications. The technologies developed by the Geothermal Technologies Program will provide the Nation with new sources of electricity that are highly reliable and cost competitive and do not add to America's air pollution or the emission of greenhouse gases. Geothermal electricity generation is not subject to fuel price volatility and supply disruptions from changes in global energy markets. Geothermal energy systems use a domestic and renewable source of energy. The Geothermal Technologies Program develops innovative technologies to find, access, and use the Nation's geothermal resources. These efforts include emphasis on Enhanced Geothermal Systems (EGS) with continued R&D on geophysical and geochemical exploration technologies, improved drilling systems, and more efficient heat exchangers and condensers. The Geothermal Technologies Program is balanced between short-term goals of greater interest to industry, and long-term goals of importance to national energy interests. The program's research and development activities are expected to increase the number of new domestic geothermal fields, increase the success rate of geothermal well drilling, and reduce the costs of constructing and operating geothermal power plants. These improvements will increase the quantity of economically viable geothermal resources, leading in turn to an increased number of geothermal power facilities serving more energy demand. These new geothermal projects will take advantage of geothermal resources in locations where development is not currently possible or

  3. Clay alteration of volcaniclastic material in a submarine geothermal system, Bay of Plenty, New Zealand

    NASA Astrophysics Data System (ADS)

    Hocking, Michael W. A.; Hannington, Mark D.; Percival, Jeanne B.; Stoffers, Peter; Schwarz-Schampera, Ulrich; de Ronde, C. E. J.

    2010-04-01

    The Calypso Hydrothermal Vent Field (CHVF) is located along an offshore extension of the Taupo Volcanic Zone (TVZ), an area of abundant volcanism and geothermal activity on the North Island of New Zealand. The field occurs within a northeast-trending submarine depression on the continental shelf approximately 10-15 km southwest of the White Island volcano in the Bay of Plenty. The graben has been partially filled by tephra from regional subaerial volcanic eruptions, and active hydrothermal venting occurs at several locations along its length. The vents occur at water depths of 160 to 190 m and have temperatures up to 201 °C. Recovered samples from the vent field include variably cemented and veined volcaniclastic sediments containing an assemblage of clay minerals, amorphous silica, barite, As-Sb-Hg sulfides, and abundant native sulfur. The volcanic glass has been altered primarily to montmorillonite and mixed-layer illite-montmorillonite; illite, and possibly minor talc and mixed-layer chlorite-smectite or chlorite-vermiculite are also present. A hydrothermal versus diagenetic origin for the smectite is indicated by the presence of both illite and mixed-layer clays and by the correlation between the abundance of clay minerals and the abundance of native sulfur in the samples. The mineralization and alteration of the volcanic host rocks are similar to that observed in near-neutral pH geothermal systems on land in the TVZ (e.g., Broadlands-Ohaaki). However, the clay minerals in the CHVF have a higher concentration of Mg in the dioctahedral layer and a higher interlayer Na content than clay minerals from Broadlands-Ohaaki, reflecting the higher concentrations of Mg and Na in seawater compared to meteoric water. Minerals formed at very low pH (e.g., kaolinite and alunite), typical of steam-heated acid-sulfate type alteration in the TVZ geothermal environment, were not found. Mixing with seawater likely prevented the formation of such low-pH mineral assemblages. The

  4. Systems study of drilling for installation of geothermal heat pumps

    SciTech Connect

    Finger, J.T.; Sullivan, W.N.; Jacobson, R.D.; Pierce, K.G.

    1997-09-01

    Geothermal, or ground-source, heat pumps (GHP) are much more efficient than air-source units such as conventional air conditioners. A major obstacle to their use is the relatively high initial cost of installing the heat-exchange loops into the ground. In an effort to identify drivers which influence installation cost, a number of site visits were made during 1996 to assess the state-of-the-art in drilling for GHP loop installation. As an aid to quantifying the effect of various drilling-process improvements, we constructed a spread-sheet based on estimated time and material costs for all the activities required in a typical loop-field installation. By substituting different (improved) values into specific activity costs, the effect on total project costs can be easily seen. This report contains brief descriptions of the site visits, key points learned during the visits, copies of the spread-sheet, recommendations for further work, and sample results from sensitivity analysis using the spread-sheet.

  5. Torbett-Hutchings-Smith Memorial Hospital geothermal-system demonstration at Marlin, Texas. Final design report

    SciTech Connect

    Not Available

    1980-09-17

    The final design and economics of the Torbett-Hutchings-Smith (THS) Memorial Hospital geothermal heating system at Marlin, Texas are outlined. A brief description of the existing heating system, an overview of the geothermal retrofit, and the results of an economic analysis are included. It is estimated that the geothermal heating system will displace approximately 84 percent of the hospital's average annual natural gas consumption. In summer conditions, approximately 45 gpm of geothermal fluid will be utilized at a wellhead temperature of 139/sup 0/F. In peak demand winter conditions, approximately 160 gpm will be utilized at a wellhead temperature of 148/sup 0/F. The geothermal fluid temperature drop across the system will range from about 5/sup 0/F in summer to over 45/sup 0/F during winter. Total capital costs for the system are estimated to be $673,000, including the production well, a geothermal equipment room, engineering and architectural costs, and all equipment. The average annual natural gas savings are expected to be $28,200 while average annual operating and maintenance costs are estimated to be $7750. A before tax life cycle economic analysis of the THS system shows the breakeven period (BEP) of 29 years falling slightly below the 30 year expected life. This BEP is significantly influenced by the developmental nature of this project and by its lack of tax incentives.

  6. Enhanced Geothermal Systems (EGS) R&D Program: Monitoring EGS-Related Research

    SciTech Connect

    McLarty, Lynn; Entingh, Daniel; Carwile, Clifton

    2000-09-29

    This report reviews technologies that could be applicable to Enhanced Geothermal Systems development. EGS covers the spectrum of geothermal resources from hydrothermal to hot dry rock. We monitored recent and ongoing research, as reported in the technical literature, that would be useful in expanding current and future geothermal fields. The literature review was supplemented by input obtained through contacts with researchers throughout the United States. Technologies are emerging that have exceptional promise for finding fractures in nonhomogeneous rock, especially during and after episodes of stimulation to enhance natural permeability.

  7. Enhanced Geothermal System Development of the AmeriCulture Leasehold in the Animas Valley

    SciTech Connect

    Duchane, David V; Seawright, Gary L; Sewright, Damon E; Brown, Don; Witcher, James c.; Nichols, Kenneth E.

    2001-03-02

    Working under the grant with AmeriCulture, Inc., and its team of geothermal experts, assembled a plan to apply enhanced geothermal systems (EGS) techniques to increase both the temperature and flow rate of the geothermal waters on its leasehold. AmeriCulture operates a commercial aquaculture facility that will benefit from the larger quantities of thermal energy and low cost electric power that EGS technology can provide. The project brought together a team of specialists that, as a group, provided the full range of expertise required to successfully develop and implement the project.

  8. Active Management of Integrated Geothermal-CO2 Storage Reservoirs in Sedimentary Formations

    DOE Data Explorer

    Buscheck, Thomas A.

    2012-01-01

    Active Management of Integrated Geothermal–CO2 Storage Reservoirs in Sedimentary Formations: An Approach to Improve Energy Recovery and Mitigate Risk: FY1 Final Report The purpose of phase 1 is to determine the feasibility of integrating geologic CO2 storage (GCS) with geothermal energy production. Phase 1 includes reservoir analyses to determine injector/producer well schemes that balance the generation of economically useful flow rates at the producers with the need to manage reservoir overpressure to reduce the risks associated with overpressure, such as induced seismicity and CO2 leakage to overlying aquifers. Based on a range of well schemes, techno-economic analyses of the levelized cost of electricity (LCOE) are conducted to determine the economic benefits of integrating GCS with geothermal energy production. In addition to considering CO2 injection, reservoir analyses are conducted for nitrogen (N2) injection to investigate the potential benefits of incorporating N2 injection with integrated geothermal-GCS, as well as the use of N2 injection as a potential pressure-support and working-fluid option. Phase 1 includes preliminary environmental risk assessments of integrated geothermal-GCS, with the focus on managing reservoir overpressure. Phase 1 also includes an economic survey of pipeline costs, which will be applied in Phase 2 to the analysis of CO2 conveyance costs for techno-economics analyses of integrated geothermal-GCS reservoir sites. Phase 1 also includes a geospatial GIS survey of potential integrated geothermal-GCS reservoir sites, which will be used in Phase 2 to conduct sweet-spot analyses that determine where promising geothermal resources are co-located in sedimentary settings conducive to safe CO2 storage, as well as being in adequate proximity to large stationary CO2 sources.

  9. Hybrid Cooling Systems for Low-Temperature Geothermal Power Production

    SciTech Connect

    Ashwood, A.; Bharathan, D.

    2011-03-01

    This paper describes the identification and evaluation of methods by which the net power output of an air-cooled geothermal power plant can be enhanced during hot ambient conditions with a minimal amount of water use.

  10. Protocol for Addressing Induced Seismicity Associated with Enhanced Geothermal Systems

    SciTech Connect

    Majer, Ernie; Nelson, James; Robertson-Tait, Ann; Savy, Jean; Wong, Ivan

    2012-01-01

    This Protocol is a living guidance document for geothermal developers, public officials, regulators and the general public that provides a set of general guidelines detailing useful steps to evaluate and manage the effects of induced seismicity related to EGS projects.

  11. Developing and circulating a fault system in the crystalline rock for geothermal power generation in Insheim, Germany.

    NASA Astrophysics Data System (ADS)

    Teza, D.; Baumgärtner, J.; Lerch, C.; Gandy, T.; Hettkamp, T.; Penzkofer, P.; Schindler, M.; Wahl, G.

    2011-12-01

    Pfalzwerke geofuture GmbH together with its general contractor BESTEC GmbH intend to build a geothermal power plant in Insheim using a single fault system in the crystalline rock for geothermal heat extraction. The Insheim site is located in the Upper Rhine Graben, about 4 km South of the geothermal power plant in Landau, Germany, and about 30 km North of the European EGS site at Soultz-sous-Forêts, France. In 2008 and 2009 two wells were successfully drilled to a depth of about 3,800 meters targeting the same fault system in the crystalline basement. The geothermal reservoir was tapped with a temperature of more than 165 degrees Celsius. In order to improve well properties and prepare both wells for safe, clean and viable power generation, circulation tests and hydraulic injections with gradually increasing flowrate were conducted in late 2009 and early 2010. Seismic monitoring networks, recording also ground velocities, along with an alarm plan ensured the success of the operations. The recorded peak ground velocities stayed far below the reference values of 3 and 5 millimeters per second, specified in the DIN 4150, while seismic activity obviously decreased during the hydraulic operations. In autumn 2010 a lateral well was drilled out of the injection well at approximately 2,500 meters, aiming to better distribute the fluid volume between the two injection branches and thus further minimize microseismic activity. During subsequent hydraulic injection tests no more seismicity was registered. The geothermal power plant in Insheim will have a capacity of 4 to 5 megawatts, capable of supplying about 8,000 homes with electrical energy. The beginning of electric power production is planned for summer 2012.

  12. Geothermic activity and seismotectonics in the altitude of the Tibetan plateau

    NASA Astrophysics Data System (ADS)

    Xu, Jiren; Zhao, Zhixin

    2009-12-01

    In the present analysis on the relationships among the depth of lithosphere brittle fracture, seismotectonics and geothermal anomalous active in Tibetan plateau were investigated using the seismic dada from ISC and Chinese seismic net and geothermal data. The results suggest that the region of anomalously geothermal activity almost coincides with that of the normal faulting type earthquake. The geothermal anomaly activity region coincides spatially with that of the events deeper than 60 km as well as. The normal faulting earthquakes may be mainly tectonic activity regimes until 110 km deep in the thermal anomaly region. The strike directions of events are likely the N-S direction, coinciding with the strike of the thermal anomaly active belts. The earthquakes align along the normal faults and faulted-depression zone with the N-S direction. The thermal anomaly activity also distributes along the faulted-depression zone. Many events deeper than 60 km exist in the anomalously geothermal activity region in the plateau. Events extend to bottom of the lithosphere of 110 km from the surface, like columnar seismic crowd. The lithosphere extends along the E-W direction due to the E-W extensional stress in the central and southern Tibetan plateau, altitude of the plateau. The tensional stress in the E-W results in the lithosphere fractures and the normal faults striking N-S direction, grabens and faulted-depression zones. Thermal material from the asthenosphere wells upward to the surface along deep seismic fractures and faults through the thick crust. The anomalously thermal activities are attributable to the upwelling thermal material from the mantle in the altitude of Tibetan plateau.

  13. The LBL geothermal reservoir technology program

    SciTech Connect

    Lippmann, M.J.

    1991-03-01

    The main objective of the DOE/GD-funded Geothermal Reservoir Technology Program at Lawrence Berkeley Laboratory is the development and testing of new and improved methods and tools needed by industry in its effort to delineate, characterize, evaluate, and exploit hydrothermal systems for geothermal energy. This paper summarizes the recent and ongoing field, laboratory, and theoretical research activities being conducted as part of the Geothermal Reservoir Technology Program. 28 refs., 4 figs.

  14. Geothermal drilling research in the United States

    SciTech Connect

    Varnado, S.G.; Maish, A.B.

    1980-01-01

    The high cost of drilling and completing geothermal wells is an impediment to the development of this resource. The Department of Energy (DOE), Division of Geothermal Energy (DGE), is conducting an R and D program directed at reducing well costs through improvements in geothermal drilling and completion technology. This program includes R and D activities in high temperature drilling hardware, drilling fluids, lost circulation control methods, completion technology, and advanced drilling systems. An overview of the program is presented.

  15. The geothermal program at Lawrence Berkeley Laboratory

    SciTech Connect

    Lippmann, M.J.

    1987-06-01

    The main purpose of the geothermal program at Lawrence Berkeley Laboratory is to develop, improve and validate methods and instrumentation to: (1) determine geothermal reservoir parameters; (2) detect and characterize reservoir fractures and boundaries; and (3) identify and evaluate the importance of reservoir processes. The ultimate objective of the program, which includes field, theoretical and modeling activities, is to advance the state-of-the-art for characterizing geothermal systems and evaluating their productive capacity and longevity under commercial exploitation.

  16. Dixie Valley Engineered Geothermal System Exploration Methodology Project, Baseline Conceptual Model Report

    DOE Data Explorer

    Joe Iovenitti

    2013-05-15

    The Engineered Geothermal System (EGS) Exploration Methodology Project is developing an exploration approach for EGS through the integration of geoscientific data. The Project chose the Dixie Valley Geothermal System in Nevada as a field laboratory site for methodlogy calibration purposes because, in the public domain, it is a highly characterized geothermal systems in the Basin and Range with a considerable amount of geoscience and most importantly, well data. This Baseline Conceptual Model report summarizes the results of the first three project tasks (1) collect and assess the existing public domain geoscience data, (2) design and populate a GIS database, and (3) develop a baseline (existing data) geothermal conceptual model, evaluate geostatistical relationships, and generate baseline, coupled EGS favorability/trust maps from +1km above sea level (asl) to -4km asl for the Calibration Area (Dixie Valley Geothermal Wellfield) to identify EGS drilling targets at a scale of 5km x 5km. It presents (1) an assessment of the readily available public domain data and some proprietary data provided by Terra-Gen Power, LLC, (2) a re-interpretation of these data as required, (3) an exploratory geostatistical data analysis, (4) the baseline geothermal conceptual model, and (5) the EGS favorability/trust mapping. The conceptual model presented applies to both the hydrothermal system and EGS in the Dixie Valley region.

  17. The Moana geothermal system in Reno, Nevada: A hydrologic, geochemical, and thermal analysis

    SciTech Connect

    Jacobson, E.A.; Johnston, J.W.

    1991-03-01

    The Moana geothermal systems, located in Reno, Nevada, is a moderate-temperature geothermal resource used for space heating applications. Both historic and new hydrologic, thermal, and groundwater chemistry data were collected to evaluate the Moana system and to develop a calibrated numerical model of the geothermal aquifer for investigation of resource development scenarios. The new data collection consisted of static water level measurements and temperature with depth measurements for a 13-month period at 26 geothermal wells to investigate hydrologic and thermal changes with time. In addition, groundwater chemistry sampling at 10 wells was used to evaluate mixing of thermal and nonthermal waters. Collected information indicates that in the most heavily used portion of the geothermal aquifer, the hydraulic heads have declined. This decline may induce additional leakage of cooler water from the overlying unconfined aquifer and lead to decreased temperatures at well locations in the geothermal aquifer. The groundwater chemistry data show concentration changes with temperature for boron, chloride, fluoride, lithium, and bicarbonate that are a function of the degree of mixing of thermal and nonthermal waters. Temporal changes in these constituents may be used as an indication of relative temperature changes in the geothermal system caused by mixing at a given location. An attempt was made to use the hydraulic head and maximum temperature data to develop a calibrated numerical model for the Moana geothermal system. However, lack of information about the horizontal and vertical thermal and fluid fluxes made the development of a calibrated model not possible at this time. 25 refs., 54 figs., 6 tabs.

  18. Applicability of `GREATEM' system in mapping geothermal regions in volcanic areas

    NASA Astrophysics Data System (ADS)

    Verma, S. K.; Mogi, T.; Abd Allah, S.

    2010-12-01

    The ‘GREATEM’ helicopter borne TEM system employs a long grounded cable as transmitter while a light weight receiver coil is flown below a helicopter. This arrangement greatly simplifies the flying logistics and speed of the survey. Also there is very little reduction in the anomaly amplitude when the survey altitude is increased. This is a great advantage particularly in volcanic regions usually having rough topography, as the ‘GREATEM’ survey can be done with helicopter flying at a safe height. Many volcanic areas have anomalous geothermal regions containing hydrothermal fluids. Eruption of volcanoes may cause changes in the thermal character and spatial distribution of these regions. Mapping of these regions is important as they may be associated with hazards. Sometimes, if the temperature is high and volume of the geothermal region is large, they can provide a good source of geothermal energy. Applicability of ‘GREATEM’ system in mapping geothermal regions in volcanic areas is studied by numerical modeling. We have considered a 3D conductor at a shallow depth (50 t0 100m), representing the anomalous geothermal region with dimensions of 500m X 500m X 500m. Different types of geological host environment are considered by varying their resistivities from 10 Ohm.m to 2000 Ohm.m. The ‘GREATEM’ response is analyzed as ‘Percentage Difference (PD)’ over the response produced by the host environment. It is found that the “GREATEM’ system can delineate the geothermal region well. Many geothermal regions are associated with a deeper (> 1 km) reservoir of much larger dimensions. In this situation also it is found that the ‘GREATEM’ system can pick up the response of the shallower geothermal region against the background response of different types of geological host environment containing the deeper reservoir (Figure 1).

  19. Energy Returned On Investment of Engineered Geothermal Systems Annual Report FY2010

    SciTech Connect

    Mansure, A.J.

    2010-12-31

    Energy Return On Investment (EROI) is an important figure of merit for assessing the viability of energy alternatives. EROI analyses of geothermal energy are either out of date or presented online with little supporting documentation. Often comparisons of energy systems inappropriately use 'efficiency' when EROI would be more appropriate. For geothermal electric power generation, EROI is determined by the electric energy delivered to the consumer compared to the energy consumed to build, operate, and decommission the facility.

  20. Environmentally Friendly, Rheoreversible, Hydraulic-fracturing Fluids for Enhanced Geothermal Systems

    SciTech Connect

    Shao, Hongbo; Kabilan, Senthil; Stephens, Sean A.; Suresh, Niraj; Beck, Anthon NR; Varga, Tamas; Martin, Paul F.; Kuprat, Andrew P.; Jung, Hun Bok; Um, Wooyong; Bonneville, Alain; Heldebrant, David J.; Carroll, KC; Moore, Joseph; Fernandez, Carlos A.

    2015-07-01

    Cost-effective creation of high-permeability reservoirs inside deep crystalline bedrock is the primary challenge for the feasibility of enhanced geothermal systems (EGS). Current reservoir stimulation entails adverse environmental impacts and substantial economic costs due to the utilization of large volumes of water “doped” with chemicals including rheology modifiers, scale and corrosion inhibitors, biocides, friction reducers among others where, typically, little or no information of composition and toxicity is disclosed. An environmentally benign, CO2-activated, rheoreversible fracturing fluid has recently been developed that significantly enhances rock permeability at effective stress significantly lower than current technology. We evaluate the potential of this novel fracturing fluid for application on geothermal sites under different chemical and geomechanical conditions, by performing laboratory-scale fracturing experiments with different rock sources under different confining pressures, temperatures, and pH environments. The results demonstrate that CO2-reactive aqueous solutions of environmentally amenable Polyallylamine (PAA) represent a highly versatile fracturing fluid technology. This fracturing fluid creates/propagates fracture networks through highly impermeable crystalline rock at significantly lower effective stress as compared to control experiments where no PAA was present, and permeability enhancement was significantly increased for PAA compared to conventional hydraulic fracturing controls. This was evident in all experiments, including variable rock source/type, operation pressure and temperature (over the entire range for EGS applications), as well as over a wide range of formation-water pH values. This versatile novel fracturing fluid technology represents a great alternative to industrially available fracturing fluids for cost-effective and competitive geothermal energy production.

  1. Advanced Horizontal Well Recirculation Systems for Geothermal Energy Recovery in Sedimentary and Crystalline Formations

    SciTech Connect

    Bruno, Mike S.; Detwiler, Russell L.; Lao, Kang; Serajian, Vahid; Elkhoury, Jean; Diessl, Julia; White, Nicky

    2012-12-13

    There is increased recognition that geothermal energy resources are more widespread than previously thought, with potential for providing a significant amount of sustainable clean energy worldwide. Recent advances in drilling, completion, and production technology from the oil and gas industry can now be applied to unlock vast new geothermal resources, with some estimates for potential electricity generation from geothermal energy now on the order of 2 million megawatts. The primary objectives of this DOE research effort are to develop and document optimum design configurations and operating practices to produce geothermal power from hot permeable sedimentary and crystalline formations using advanced horizontal well recirculation systems. During Phase I of this research project Terralog Technologies USA and The University of California, Irvine (UCI), have completed preliminary investigations and documentation of advanced design concepts for paired horizontal well recirculation systems, optimally configured for geothermal energy recovery in permeable sedimentary and crystalline formations of varying structure and material properties. We have also identified significant geologic resources appropriate for application of such technology. The main challenge for such recirculation systems is to optimize both the design configuration and the operating practices for cost-effective geothermal energy recovery. These will be strongly influenced by sedimentary formation properties, including thickness and dip, temperature, thermal conductivity, heat capacity, permeability, and porosity; and by working fluid properties.

  2. G.R.I.P.S activities in the development of direct use of geothermal resources and small scale geothermal power development

    NASA Astrophysics Data System (ADS)

    1981-10-01

    The activities of the geothermal research information and planning services (G.R.I.P.S.) in the four Geysers-Calistoga KGRA counties (i.e., Lake, Mendocino, Napa, Sonoma) in California are reported. Activities in the G.R.I.P.S. information and outreach program, workshop presentations, pilot project development, permit processing improvements and Department of Energy reporting are described.

  3. Geochemical features of the geothermal fluids from the Mapamyum non-volcanic geothermal system (Western Tibet, China)

    NASA Astrophysics Data System (ADS)

    Wang, Peng; Chen, Xiaohong; Shen, Licheng; Wu, Kunyu; Huang, Mingzhi; Xiao, Qiong

    2016-06-01

    Mapamyum geothermal field (MGF) in western Tibet is one of largest geothermal areas characterized by the occurrence of hydrothermal explosions on the Tibetan Plateau. The geochemical properties of hydrothermal water in the MGF system were investigated to trace the origin of the solutes and to determine the equilibrium temperatures of the feeding reservoir. The study results show that the geochemistry of hydrothermal waters in the MGF system is mainly of the Na-HCO3 type. The chemical components of hydrothermal waters are mainly derived from the minerals in the host rocks (e.g., K-feldspar, albite, Ca-montmorillonite, and Mg-montmorillonite). The hydrothermal waters are slightly supersaturated or undersaturated with respect to aragonite, calcite, dolomite, chalcedony and quartz (saturation indices close to 0), but are highly undersaturated with respect to gypsum and anhydrite (saturation indices < 0). Mixing models and Na-K-Mg ternary diagrams show that strong mixing between cold meteoric water and deeply-seated thermal fluids occurred during the upward flowing process. δD and δ18O data confirm that the meteoric water acts as the water source of the geothermal waters. An ~ 220 °C equilibrated reservoir temperature of hydrothermal spring waters was calculated via both the Na-K-Mg ternary diagrams and the cationic chemical geothermometers. The logpCO2 of hydrothermal waters in the MGF system ranges from - 2.59 to - 0.57 and δ13C of the total dissolved inorganic carbon ranges from - 5.53‰ to - 0.94‰, suggesting that the carrier CO2 in hydrothermal water are mainly of a magmatic or metamorphic CO2 origin.

  4. Recovery Act: Geothermal Data Aggregation: Submission of Information into the National Geothermal Data System, Final Report DOE Project DE-EE0002852 June 24, 2014

    SciTech Connect

    Blackwell, David D.; Chickering Pace, Cathy; Richards, Maria C.

    2014-06-24

    The National Geothermal Data System (NGDS) is a Department of Energy funded effort to create a single cataloged source for a variety of geothermal information through a distributed network of databases made available via web services. The NGDS will help identify regions suitable for potential development and further scientific data collection and analysis of geothermal resources as a source for clean, renewable energy. A key NGDS repository or ‘node’ is located at Southern Methodist University developed by a consortium made up of: • SMU Geothermal Laboratory • Siemens Corporate Technology, a division of Siemens Corporation • Bureau of Economic Geology at the University of Texas at Austin • Cornell Energy Institute, Cornell University • Geothermal Resources Council • MLKay Technologies • Texas Tech University • University of North Dakota. The focus of resources and research encompass the United States with particular emphasis on the Gulf Coast (on and off shore), the Great Plains, and the Eastern U.S. The data collection includes the thermal, geological and geophysical characteristics of these area resources. Types of data include, but are not limited to, temperature, heat flow, thermal conductivity, radiogenic heat production, porosity, permeability, geological structure, core geophysical logs, well tests, estimated reservoir volume, in situ stress, oil and gas well fluid chemistry, oil and gas well information, and conventional and enhanced geothermal system related resources. Libraries of publications and reports are combined into a unified, accessible, catalog with links for downloading non-copyrighted items. Field notes, individual temperature logs, site maps and related resources are included to increase data collection knowledge. Additional research based on legacy data to improve quality increases our understanding of the local and regional geology and geothermal characteristics. The software to enable the integration, analysis, and

  5. Gas and water geochemistry of geothermal systems in Dominica, Lesser Antilles island arc

    NASA Astrophysics Data System (ADS)

    Joseph, Erouscilla P.; Fournier, Nicolas; Lindsay, Jan M.; Fischer, Tobias P.

    2011-09-01

    Four of the nine potentially active volcanoes on the island of Dominica in the Lesser Antilles volcanic island arc have associated active volcanic-hydrothermal systems. Between 2000 and 2006 the gas and thermal waters from these systems were investigated to geochemically characterise the fluids, gain insight into the temperature and equilibrium state of the underlying reservoirs, and evaluate the feasibility of monitoring geothermal features as a volcano surveillance tool in Dominica. The geothermal gases are typical of those found in arc-type settings, with N 2 excess and low amounts of He and Ar. The dry gas is dominated by CO 2 (ranging from 492 to 993 mmol/mol), and has a hydrothermal signature with hydrogen sulphide as the main sulphurous gas. The waters are predominantly acid-sulphate (SO 4 = 100-4200 mg/L, pH ≤ 4), and likely formed as a result of dilution of acidic gases in near surface oxygenated groundwater. Enrichment in both δ 18O and δD with respect to the global meteoric water line (GMWL) confirms that the waters are of primarily meteoric origin, but have been affected by evaporation processes. Quartz geothermometers gave equilibrium temperatures of 83 °C-203 °C. These temperatures contrast with the higher equilibrium temperature ranges (170 °C-350 °C) obtained for the gases using the H 2/Ar*-CH 4/CO 2 gas ratios plot, suggesting that the quartz geothermometers are affected by non-attainment of equilibrium. This may be a result of precipitation of the dissolved silica and/or dilution by relatively cold shallow aquifers of the thermal fluids. Generally, no significant variations in fluid gas chemistry of the hydrothermal systems were observed during the study period, and we propose that there were no changes in the state of volcanic activity in this period. One exception to this occurred in a feature known as the Boiling Lake, which underwent a month-long period of significant compositional, temperature and water level fluctuations ascribed to

  6. Impact of enhanced geothermal systems on US energy supply in the twenty-first century.

    PubMed

    Tester, Jefferson W; Anderson, Brian J; Batchelor, Anthony S; Blackwell, David D; DiPippo, Ronald; Drake, Elisabeth M; Garnish, John; Livesay, Bill; Moore, Michal C; Nichols, Kenneth; Petty, Susan; Toksoz, M Nafi; Veatch, Ralph W; Baria, Roy; Augustine, Chad; Murphy, Enda; Negraru, Petru; Richards, Maria

    2007-04-15

    Recent national focus on the value of increasing US supplies of indigenous renewable energy underscores the need for re-evaluating all alternatives, particularly those that are large and well distributed nationally. A panel was assembled in September 2005 to evaluate the technical and economic feasibility of geothermal becoming a major supplier of primary energy for US base-load generation capacity by 2050. Primary energy produced from both conventional hydrothermal and enhanced (or engineered) geothermal systems (EGS) was considered on a national scale. This paper summarizes the work of the panel which appears in complete form in a 2006 MIT report, 'The future of geothermal energy' parts 1 and 2. In the analysis, a comprehensive national assessment of US geothermal resources, evaluation of drilling and reservoir technologies and economic modelling was carried out. The methodologies employed to estimate geologic heat flow for a range of geothermal resources were utilized to provide detailed quantitative projections of the EGS resource base for the USA. Thirty years of field testing worldwide was evaluated to identify the remaining technology needs with respect to drilling and completing wells, stimulating EGS reservoirs and converting geothermal heat to electricity in surface power and energy recovery systems. Economic modelling was used to develop long-term projections of EGS in the USA for supplying electricity and thermal energy. Sensitivities to capital costs for drilling, stimulation and power plant construction, and financial factors, learning curve estimates, and uncertainties and risks were considered.

  7. Modeling of a deep-seated geothermal system near Tianjin, China.

    PubMed

    Xun, Z; Mingyou, C; Weiming, Z; Minglang, L

    2001-01-01

    A geothermal field is located in deep-seated basement aquifers in the northeastern part of the North China Plain near Tianjin, China. Carbonate rocks of Ordovician and Middle and Upper Proterozoic age on the Cangxian Uplift are capable of yielding 960 to 4200 m3/d of 57 degrees C to 96 degrees C water to wells from a depth of more than 1000 m. A three-dimensional nonisothermal numerical model was used to simulate and predict the spatial and temporal evolution of pressure and temperature in the geothermal system. The density of the geothermal water, which appears in the governing equations, can be expressed as a linear function of pressure, temperature, and total dissolved solids. A term describing the exchange of heat between water and rock is incorporated in the governing heat transport equation. Conductive heat flow from surrounding formations can be considered among the boundary conditions. Recent data of geothermal water production from the system were used for a first calibration of the numerical model. The calibrated model was used to predict the future changes in pressure and temperature of the geothermal water caused by two pumping schemes. The modeling results indicate that both pressure and temperature have a tendency to decrease with time and pumping. The current withdrawal rates and a pumping period of five months followed by a shut-off period of seven months are helpful in minimizing the degradation of the geothermal resource potential in the area. PMID:11341010

  8. Modeling of a deep-seated geothermal system near Tianjin, China.

    PubMed

    Xun, Z; Mingyou, C; Weiming, Z; Minglang, L

    2001-01-01

    A geothermal field is located in deep-seated basement aquifers in the northeastern part of the North China Plain near Tianjin, China. Carbonate rocks of Ordovician and Middle and Upper Proterozoic age on the Cangxian Uplift are capable of yielding 960 to 4200 m3/d of 57 degrees C to 96 degrees C water to wells from a depth of more than 1000 m. A three-dimensional nonisothermal numerical model was used to simulate and predict the spatial and temporal evolution of pressure and temperature in the geothermal system. The density of the geothermal water, which appears in the governing equations, can be expressed as a linear function of pressure, temperature, and total dissolved solids. A term describing the exchange of heat between water and rock is incorporated in the governing heat transport equation. Conductive heat flow from surrounding formations can be considered among the boundary conditions. Recent data of geothermal water production from the system were used for a first calibration of the numerical model. The calibrated model was used to predict the future changes in pressure and temperature of the geothermal water caused by two pumping schemes. The modeling results indicate that both pressure and temperature have a tendency to decrease with time and pumping. The current withdrawal rates and a pumping period of five months followed by a shut-off period of seven months are helpful in minimizing the degradation of the geothermal resource potential in the area.

  9. Development of a Deep-Penetrating, Compact Geothermal Heat Flow System for Robotic Lunar Geophysical Missions

    NASA Technical Reports Server (NTRS)

    Nagihara, Seiichi; Zacny, Kris; Hedlund, Magnus; Taylor, Patrick T.

    2012-01-01

    Geothermal heat flow measurements are a high priority for the future lunar geophysical network missions recommended by the latest Decadal Survey of the National Academy. Geothermal heat flow is obtained as a product of two separate measurements of geothermal gradient and thermal conductivity of the regolith/soil interval penetrated by the instrument. The Apollo 15 and 17 astronauts deployed their heat flow probes down to 1.4-m and 2.3-m depths, respectively, using a rotary-percussive drill. However, recent studies show that the heat flow instrument for a lunar mission should be capable of excavating a 3-m deep hole to avoid the effect of potential long-term changes of the surface thermal environment. For a future robotic geophysical mission, a system that utilizes a rotary/percussive drill would far exceed the limited payload and power capacities of the lander/rover. Therefore, we are currently developing a more compact heat flow system that is capable of 3-m penetration. Because the grains of lunar regolith are cohesive and densely packed, the previously proposed lightweight, internal hammering systems (the so-called moles ) are not likely to achieve the desired deep penetration. The excavation system for our new heat flow instrumentation utilizes a stem which winds out of a pneumatically driven reel and pushes its conical tip into the regolith. Simultaneously, gas jets, emitted from the cone tip, loosen and blow away the soil. Lab tests have demonstrated that this proboscis system has much greater excavation capability than a mole-based heat flow system, while it weighs about the same. Thermal sensors are attached along the stem and at the tip of the penetrating cone. Thermal conductivity is measured at the cone tip with a short (1- to 1.5-cm long) needle sensor containing a resistance temperature detector (RTD) and a heater wire. When it is inserted into the soil, the heater is activated. Thermal conductivity of the soil is obtained from the rate of temperature

  10. Real-time fracture monitoring in Engineered Geothermal Systems with seismic waves

    SciTech Connect

    Jose A. Rial; Jonathan Lees

    2009-03-31

    As proposed, the main effort in this project is the development of software capable of performing real-time monitoring of micro-seismic activity recorded by an array of sensors deployed around an EGS. The main milestones are defined by the development of software to perform the following tasks: • Real-time micro-earthquake detection and location • Real-time detection of shear-wave splitting • Delayed-time inversion of shear-wave splitting These algorithms, which are discussed in detail in this report, make possible the automatic and real-time monitoring of subsurface fracture systems in geothermal fields from data collected by an array of seismic sensors. Shear wave splitting (SWS) is parameterized in terms of the polarization of the fast shear wave and the time delay between the fast and slow shear waves, which are automatically measured and stored. The measured parameters are then combined with previously measured SWS parameters at the same station and used to invert for the orientation (strike and dip) and intensity of cracks under that station. In addition, this grant allowed the collection of seismic data from several geothermal regions in the US (Coso) and Iceland (Hengill) to use in the development and testing of the software.

  11. Creation of an Enhanced Geothermal System through Hydraulic and Thermal Stimulation

    SciTech Connect

    Rose, Peter Eugene

    2013-04-15

    This report describes a 10-year DOE-funded project to design, characterize and create an Engineered Geothermal System (EGS) through a combination of hydraulic, thermal and chemical stimulation techniques. Volume 1 describes a four-year Phase 1 campaign, which focused on the east compartment of the Coso geothermal field. It includes a description of the geomechanical, geophysical, hydraulic, and geochemical studies that were conducted to characterize the reservoir in anticipation of the hydraulic stimulation experiment. Phase 1 ended prematurely when the drill bit intersected a very permeable fault zone during the redrilling of target stimulation well 34-9RD2. A hydraulic stimulation was inadvertently achieved, however, since the flow of drill mud from the well into the formation created an earthquake swarm near the wellbore that was recorded, located, analyzed and interpreted by project seismologists. Upon completion of Phase 1, the project shifted focus to a new target well, which was located within the southwest compartment of the Coso geothermal field. Volume 2 describes the Phase 2 studies on the geomechanical, geophysical, hydraulic, and geochemical aspects of the reservoir in and around target-stimulation well 46A-19RD, which is the deepest and hottest well ever drilled at Coso. Its total measured depth exceeding 12,000 ft. It spite of its great depth, this well is largely impermeable below a depth of about 9,000 ft, thus providing an excellent target for stimulation. In order to prepare 46A-19RD for stimulation, however, it was necessary to pull the slotted liner. This proved to be unachievable under the budget allocated by the Coso Operating Company partners, and this aspect of the project was abandoned, ending the program at Coso. The program then shifted to the EGS project at Desert Peak, which had a goal similar to the one at Coso of creating an EGS on the periphery of an existing geothermal reservoir. Volume 3 describes the activities that the Coso team

  12. The Role of Boron-Chloride and Noble Gas Isotope Ratios in TVZ Geothermal Systems

    SciTech Connect

    Hulston, J.R.

    1995-01-01

    The model of the geothermal system in which deep circulating groundwater containing noble gases, at air saturated water concentrations, mixes with hot fluids of mantle origin at depth, is extended to include the effect of interaction of the ascending fluid with both solid and gaseous phases of basement (or other) rocks en route to the surface. It is demonstrated that this interaction is responsible for most of the CO{sub 2} in the Taupo Volcanic Zone (TVZ) geothermal systems. It is proposed that the modeling of this interaction might be accomplished by techniques similar to those used for the understanding of the oxygen isotope shift found in geothermal systems. The water rock interaction experiments of Ellis and Mahon (1964, 1967) provides some data on the kinetic rates for B and Cl dissolution from rocks likely to be encountered in the geothermal system, but further information on the behavior of B may be needed. If these problems can be overcome this modeling technique has promise for the estimation of the recharge of geothermal systems and hence the sustainability of these systems.

  13. Geochemical properties of groundwater used to geothermal cooling and heating system

    NASA Astrophysics Data System (ADS)

    Kim, Namju; Park, Youngyun; Lee, Jin-Yong

    2013-04-01

    Recently, geothermal cooling and heating system has been used in many countries to reduce emission of greenhouse gases such as water vapour and carbon dioxide (CO2). Especially, CO2 is emitted from combustion of fossil fuel used for cooling and heating of buildings. Therefore, many countries make an effort to reduce amount of CO2 emitted from use of fossil fuel. The geothermal cooling and heating system is good to reduce amount of CO2. Especially, open loop geothermal system shows good thermal efficiency. However, groundwater contaminations will be considered because groundwater is directly used in open loop geothermal system. This study was performed to examine chemical and isotope compositions of groundwater used in open loop geothermal system and to evaluate influence of the system on groundwater using hydrochemical modeling program (preequc). Water temperature of well used in the system (GH) and well around the system (GB) ranged from 8.4 to 17.0 ° and from 15.1 to 18.0 °, respectively. The water temperature in GH was lower than that in GB because of heating mode of the system. Also, EC in GH and GB showed significant difference. The variation trend of EC was different at each site where the system was installed. These results mean that main factors controlling EC in GH was not the system. Generally, EC of groundwater was influenced by water-rock interaction. However, DO and Eh hardly showed significant difference. The operation period of the system observed in this study was short than 5 years. Therefore, influence of the open loop geothermal system on groundwater did not shown significantly. However, while Fe2+ and Mn2+ were not observed in GB, these components were measured in GH. The concentrations of Fe2+ and Mn2+ in GH ranged from 0.02 to 0.14 mg/L and from 0.03 to 0.18 mg/L, respectively. These results mean that redox conditions of GH were changed by the system little by little. In this study, influence of the open loop geothermal system on groundwater

  14. Generic Guide Specification for Geothermal Heat Pump Systems

    SciTech Connect

    Thomas, WKT

    2000-04-12

    The attached Geothermal (Ground-Source) Heat Pump (GHP) Guide Specifications have been developed by Oak Ridge National Laboratory (ORNL) with the intent to assist federal agency sites and engineers in the preparation of construction specifications for GHP projects. These specifications have been developed in the industry-standard Construction Specification Institute (CSI) format and cover several of the most popular members of the family of GHP systems. These guide specifications are applicable to projects whether the financing is with conventional appropriations, arranged by GHP specialty ESCOs under the U.S. Department of Energy's Technology-Specific GHP Super ESPCs, arranged by utilities under Utility Energy Service Contracts (UESCs) or arranged by generalist ESCOs under the various regional ESPCs. These specifications can provide several benefits to the end user that will help ensure successful GHP system installations. GHP guide specifications will help to streamline the specification development, review, and approval process because the architecture and engineering (AE) firm will be working from the familiar CSI format instead of developing the specifications from other sources. The guide specifications help to provide uniformity, standardization, and consistency in both the construction specifications and system installations across multiple federal sites. This standardization can provide future benefits to the federal sites in respect to both maintenance and operations. GHP guide specifications can help to ensure that the agency is getting its money's worth from the GHP system by preventing the use of marginal or inferior components and equipment. The agency and its AE do not have to start from scratch when developing specifications and can use the specification as a template and/or a checklist in developing both the design and the contract documents. The guide specifications can save project costs by reducing the engineering effort required during the

  15. A geochemical model of the Platanares geothermal system, Honduras

    USGS Publications Warehouse

    Janik, C.J.; Truesdell, A.H.; Goff, F.; Shevenell, L.; Stallard, M.L.; Trujillo, P.E.; Counce, D.

    1991-01-01

    Results of exploration drilling combined with results of geologic, geophysical, and hydrogeochemical investigations have been used to construct a geochemical model of the Platanares geothermal system, Honduras. Three coreholes were drilled, two of which produced fluids from fractured Miocene andesite and altered Cretaceous to Eocene conglomerate at 450 to 680 m depth. Large volume artesian flows of 160-165??C, predominantly bicarbonate water are chemically similar to, but slightly less saline than widespread boiling hot-spring waters. The chemistry of the produced fluid is dominated by equilibrium reactions in sedimentary rocks at greater depths and higher temperatures than those measured in the wells. Chemical, isotope, and gas geothermometers indicate a deep fluid temperature of 200-245??C and reflect a relatively short residence time in the fractures feeding the wells. Chloride-enthalpy relations as well as isotopic and chemical compositions of well discharges, thermal springs, and local cold waters support a conceptual model of ascending high-temperature (minimum 225??C) parent fluid that has cooled conductively to form the 160-165??C shallow (to 680 m) fluid encountered by the wells. The hot-spring waters are formed by boiling and steam loss from more or less conductively cooled parent fluid. The more dilute boiling spring waters (Cl = ???32 mg/kg) have cooled from > 225??C to about 160??C by conduction and from 160??C to 98??C by boiling. The most concentrated boiling spring waters (Cl = 37 mg/kg) have cooled from > 225??C to about 200??C by conduction and from 200??C to 98??C by boiling. Intermediate concentrations reflect mixed cooling paths. ?? 1991.

  16. Integrated Geologic and Geophysical Approach for Establishing Geothermal Play Fairways and Discovering Blind Geothermal Systems in the Great Basin Region, Western USA: A Progress Report

    SciTech Connect

    Faulds, James E.; Hinz, Nicholas H.; Coolbaugh, Mark F.; Shevenell, Lisa A.; Siler, Drew L.; dePolo, Craig M.; Hammond, William C.; Kreemer, Corne; Oppliger, G.; Wannamaker, P.; Queen, John H.; Visser, Charles

    2015-09-02

    We have undertaken an integrated geologic, geochemical, and geophysical study of a broad 240-km-wide, 400-km-long transect stretching from west-central to eastern Nevada in the Great Basin region of the western USA. The main goal of this study is to produce a comprehensive geothermal potential map that incorporates up to 11 parameters and identifies geothermal play fairways that represent potential blind or hidden geothermal systems. Our new geothermal potential map incorporates: 1) heat flow; 2) geochemistry from springs and wells; 3) structural setting; 4) recency of faulting; 5) slip rates on Quaternary faults; 6) regional strain rate; 7) slip and dilation tendency on Quaternary faults; 8) seismologic data; 9) gravity data; 10) magnetotelluric data (where available); and 11) seismic reflection data (primarily from the Carson Sink and Steptoe basins). The transect is respectively anchored on its western and eastern ends by regional 3D modeling of the Carson Sink and Steptoe basins, which will provide more detailed geothermal potential maps of these two promising areas. To date, geological, geochemical, and geophysical data sets have been assembled into an ArcGIS platform and combined into a preliminary predictive geothermal play fairway model using various statistical techniques. The fairway model consists of the following components, each of which are represented in grid-cell format in ArcGIS and combined using specified weights and mathematical operators: 1) structural component of permeability; 2) regional-scale component of permeability; 3) combined permeability, and 4) heat source model. The preliminary model demonstrates that the multiple data sets can be successfully combined into a comprehensive favorability map. An initial evaluation using known geothermal systems as benchmarks to test interpretations indicates that the preliminary modeling has done a good job assigning relative ranks of geothermal potential. However, a major challenge is defining

  17. Thermal regime of the Great Basin and its implications for enhanced geothermal systems and off-grid power

    USGS Publications Warehouse

    Sass, John H.; Walters, Mark A.

    1999-01-01

    The Basin and Range Province of the Western United States covers most of Nevada and parts of adjoining states. It was formed by east-west tectonic extension that occurred mostly between 50 and 10 Ma, but which still is active in some areas. The northern Basin and Range, also known as the Great Basin, is higher in elevation, has higher regional heat flow and is more tectonically active than the southern Basin and Range which encompasses the Mojave and Sonoran Deserts. The Great Basin terrane contains the largest number of geothermal power plants in the United States, although most electrical production is at The Geysers and in the Salton Trough. Installed capacities of electrical power plants in the Great Basin vary from 1 to 260 MWe. Productivity is limited largely by permeability, relatively small productive reservoir volumes, available water, market conditions and the availability of transmission lines. Accessible, in-place heat is not a limiting condition for geothermal systems in the Great Basin. In many areas, economic temperatures (>120°C) can be found at economically drillable depths making it an appropriate region for implementation of the concept of "Enhanced Geothermal Systems" (EGS). An incremental approach to EGS would involve increasing the productivity and longevity of existing hydrothermal systems. Those geothermal projects that have an existing power plant and transmission facilities are the most attractive EGS candidates. Sites that were not developed owing to marginal size, lack of intrinsic permeability, and distance to existing electrical grid lines are also worthy of consideration for off-grid power production in geographically isolated markets such as ranches, farms, mines, and smelters.

  18. (Sulfide-oxide-silicate phase equilibria and associated fluid inclusion properties in the Salton Sea geothermal system, California)

    SciTech Connect

    McKibben, M.A.

    1988-06-01

    Our studies involved petrographic, fluid inclusion, geochemical and stable isotopic studies of drillcores and fluids from the Salton Sea geothermal system. Our initial studies revealed the presence of previously-unrecognized evaporitic anhydrite at depth throughout the geothermal system. The high salinity of the Salton Sea geothermal brines previously had been attributed to low-temperature dissolution of surficial evaporitic deposits by meteoric waters. Our microthermometric studies of halite--containing fluid inclusions in the meta-evaporites indicated that the high salinity of the geothermal brines is derived in part from the hydrothermal metamorphism of relatively deeply-buried salt and evaporites. In addition, our research concentrated on mineralized fractures in drillcores.

  19. Plant adaptation to extreme environments: the example of Cistus salviifolius of an active geothermal alteration field.

    PubMed

    Bartoli, Giacomo; Bottega, Stefania; Forino, Laura M C; Ciccarelli, Daniela; Spanò, Carmelina

    2014-02-01

    Cistus salviifolius is able to colonise one of the most extreme active geothermal alteration fields in terms of both soil acidity and hot temperatures. The analyses of morpho-functional and physiological characters, investigated in leaves of plants growing around fumaroles (G leaves) and in leaves developed by the same plants after transfer into growth chamber under controlled conditions (C leaves) evidenced the main adaptive traits developed by this pioneer plant in a stressful environment. These traits involved leaf shape and thickness, mesophyll compactness, stomatal and trichome densities, chloroplast size. Changes of functional and physiological traits concerned dry matter content, peroxide and lipid peroxidation, leaf area, relative water and pigment contents. A higher reducing power and antioxidant enzymatic activity were typical of G leaves. Though the high levels of stress parameters, G leaves showed stress-induced specific morphogenic and physiological responses putatively involved in their surviving in active geothermal habitats.

  20. Plant adaptation to extreme environments: the example of Cistus salviifolius of an active geothermal alteration field.

    PubMed

    Bartoli, Giacomo; Bottega, Stefania; Forino, Laura M C; Ciccarelli, Daniela; Spanò, Carmelina

    2014-02-01

    Cistus salviifolius is able to colonise one of the most extreme active geothermal alteration fields in terms of both soil acidity and hot temperatures. The analyses of morpho-functional and physiological characters, investigated in leaves of plants growing around fumaroles (G leaves) and in leaves developed by the same plants after transfer into growth chamber under controlled conditions (C leaves) evidenced the main adaptive traits developed by this pioneer plant in a stressful environment. These traits involved leaf shape and thickness, mesophyll compactness, stomatal and trichome densities, chloroplast size. Changes of functional and physiological traits concerned dry matter content, peroxide and lipid peroxidation, leaf area, relative water and pigment contents. A higher reducing power and antioxidant enzymatic activity were typical of G leaves. Though the high levels of stress parameters, G leaves showed stress-induced specific morphogenic and physiological responses putatively involved in their surviving in active geothermal habitats. PMID:24581804

  1. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Annual report, January 1984-September 1984

    SciTech Connect

    Smith, K.

    1984-09-01

    Progress is reported on a project to use the 130/sup 0/F geothermal resource in central Texas. The system for cascading geothermal energy through aquaculture and greenhouse systems was completed and the first shrimp harvest was held. (MHR)

  2. Geothermal power generation

    SciTech Connect

    Crane, G.K.

    1981-01-01

    The Southern California Edison Co. geothermal program is described in general. The individual power plant projects are described: Brawley 10 MW, Heber 45 MW and Salton Sea 9 MW. Related geothermal activities are mentioned.

  3. Heat and mass transfer in the Klamath Falls, Oregon, geothermal system

    SciTech Connect

    Prucha, R.H.

    1987-05-01

    Over the last 50 years significant amounts of data have been obtained from the Klamath Falls geothermal resource. To date, the complexity of the system has perplexed researchers, leading to the development of only very generalized hydrogeologic and geothermal models of the area. Based on reevaluation of all available data, a detailed conceptual model for the Klamath Falls geothermal resource is proposed. A comprehensive 3-dimensional numerical model, based on the proposed conceptual model is also presented. This numerical model incorporates all of the main reservoir characteristics. Hot water recharge flows from depth, along a large normal fault, and flows into near surface permeable strata where it loses heat to surrounding beds and to mixing with cold regional groundwaters introduced from the north. By matching calculated and measured temperatures and pressures, hot and cold water recharge rates and the permeability distribution for the geothermal system are estimated. A semi-analytic solution and simple lumped parameter methods are also compared to the numerical analysis. Results suggest that the flow patterns within the geothermal system at Klamath Falls are complex and intimately associated with the permeability distribution and the pressures and temperatures at depth, within the faults.

  4. Hydrology of the Greater Tongonan geothermal system, Philippines, as deduced from geochemical and isotopic data

    SciTech Connect

    Alvis-Isidro, R.R.; Solana, R.R.; D`amore, F.; Nuti, S.; Gonfiantini, R.

    1993-10-01

    Fluids in the Greater Tongonan geothermal system exhibit a large positive {sup 18}O shift from the Leyte meteoric water line. However, there is also a significant shift in {sup 2}H. The {delta}{sup 2}H-{delta}{sup 18}O plot shows that the geothermal fluids may be derived by the mixing of meteoric water with local magmatic water. The most enriched water in the Greater Tongonan system, in terms of {delta}{sup 18}O, {delta}{sup 2}H and Cl, is comprised of approximately 40% magmatic water. Baseline isotope results support a hydrogeochemical model in which there is increasing meteoric water dilution to the southeast, from Mahiao to Sambaloran and towards Malitbog. The Cl-{delta}{sup 18}O plot confirms that the geothermal fluid in Mahanagdong, further southeast, is distinct from that of the Mahiao-Sambaloran-Malitbog system.

  5. Technical support for geopressured-geothermal well activities in Louisiana. Annual report, 1 November 1982-31 October 1983

    SciTech Connect

    Not Available

    1984-10-31

    This annual report describes environmental monitoring of microseismic activity, land-surface elevations, and surface and ground-water quality at three designed geopressured-geothermal test well sites in Louisiana.

  6. Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

    SciTech Connect

    Jarrell, Mark

    2013-09-30

    Cedarville School District retrofitted the heating and cooling systems in three campus areas (High School, Middle School, and Upper Elementary School) with geothermal heat pumps and ground source water loops, as a demonstration project for the effective implementation of geothermal heat pump systems and other energy efficiency and air quality improvements.

  7. Geothermal exploration in Indonesia

    SciTech Connect

    Radja, V.T.

    1984-03-01

    Indonesia is blessed with geothermal resources. This fortunate aspect is directly related to the fact that the archipelago is an island arc created by a subduction zone. Evidence of geothermal activity is common throughout the Islands. Among the islands' many active volcanos are numerous geothermal phenomena. Almost half of the volcanic centers in Indonesia (88 out of 177 centers) contain fumarole and sulfatare features. A brief history of the exploration for geothermal energy in Indonesia is presented.

  8. Wine Valley Inn: A mineral water spa in Calistoga, California. Geothermal-energy-system conceptual design and economic feasibility

    SciTech Connect

    Not Available

    1981-10-26

    The purpose of this study is to determine the engineering and economic feasibility for utilizing geothermal energy for air conditioning and service water heating at the Wine Valley Inn, a mineral water spa in Calistoga, California. The study evaluates heating, ventilating, air conditioning and water heating systems suitable for direct heat geothermal application. Due to the excellent geothermal temperatures available at this site, the mechanics and economics of a geothermally powered chilled water cooling system are evaluated. The Wine Valley Inn has the resource potential to have one of the few totally geothermal powered air conditioning and water heating systems in the world. This total concept is completely developed. A water plan was prepared to determine the quantity of water required for fresh water well development based on the special requirements of the project. An economic evaluation of the system is included to justify the added capital investment needed to build the geothermally powered mineral spa. Energy payback calculations are presented. A thermal cascade system is proposed to direct the geothermal water through the energy system to first power the chiller, then the space heating system, domestic hot water, the two spas and finally to heat the swimming pool. The Energy Management strategy required to automatically control this cascade process using industrial quality micro-processor equipment is described. Energy Management controls are selected to keep equipment sizing at a minimum, pump only the amount of geothermal water needed and be self balancing.

  9. Seismic methods for resource exploration in enhanced geothermal systems

    SciTech Connect

    Gritto, Roland; Majer, Ernest L.

    2002-06-12

    A finite-difference modeling study of seismic wave propagation was conducted to determine how to best investigate subsurface faults and fracture zones in geothermal areas. The numerical model was created based on results from a previous seismic reflection experiment. A suite of fault models was investigated including blind faults and faults with surface expressions. The seismic data suggest that blind faults can be detected by a sudden attenuation of seismic wave amplitudes, as long the fault is located below the receiver array. Additionally, a conversion from P- to S-waves indicates the reflection and refraction of the P-waves while propagating across the fault. The drop in amplitudes and the excitation of S-waves can be used to estimate the location of the fault at depth. The accuracy of the numerical modeling depends on the availability of a priori in situ information (velocity and density) from borehole experiments in the geothermal area.

  10. ASSESSMENT OF HIGH-TEMPERATURE GEOTHERMAL RESOURCES IN HYDROTHERMAL CONVECTION SYSTEMS IN THE UNITED STATES.

    USGS Publications Warehouse

    Nathenson, Manuel

    1984-01-01

    The amount of thermal energy in high-temperature geothermal systems (>150 degree C) in the United States has been calculated by estimating the temperature, area, and thickness of each identified system. These data, along with a general model for recoverability of geothermal energy and a calculation that takes account of the conversion of thermal energy to electricity, yield a resource estimate of 23,000 MWe for 30 years. The undiscovered component was estimated based on multipliers of the identified resource as either 72,000 or 127,000 MWe for 30 years depending on the model chosen for the distribution of undiscovered energy as a function of temperature.

  11. Modeling of heat extraction from variably fractured porous media in Enhanced Geothermal Systems

    DOE PAGES

    Hadgu, Teklu; Kalinina, Elena Arkadievna; Lowry, Thomas Stephen

    2016-01-30

    Modeling of heat extraction in Enhanced Geothermal Systems is presented. The study builds on recent studies on the use of directional wells to improve heat transfer between doublet injection and production wells. The current study focuses on the influence of fracture orientation on production temperature in deep low permeability geothermal systems, and the effects of directional drilling and separation distance between boreholes on heat extraction. The modeling results indicate that fracture orientation with respect to the well-pair plane has significant influence on reservoir thermal drawdown. As a result, the vertical well doublet is impacted significantly more than the horizontal wellmore » doublet« less

  12. The Suitability of Conductive and Convective Geothermal Resources in New Mexico for EGS Systems

    NASA Astrophysics Data System (ADS)

    Person, M. A.; Owens, L.; Hubbling, J.; Kelley, S.; Witcher, J. C.; Lucero, S.

    2010-12-01

    The State of New Mexico is endowed with both deep conductive and shallow convective geothermal prospects. Shallow convective resources are associated with relatively permeable, fractured crystalline plutonic, volcanic and sedimentary bedrock units. In most instances, hot springs associated with these systems are located along gaps in Paleozoic to Tertiary confining units that form hydrogeologic windows. Hydrogeologic windows are created either from tectonic or erosional unroofing of permeable units or juxtaposition of permeable units by fault block rotation or the emplacement of fractured volcanic dikes. Other hydrogeologic windows form as a result of close-spaced faulting associated with normal fault accommodation or transfer zones. These systems have broad areas of low and background heat flow in recharge areas and deep lateral flow domains with narrow regions of extremely high heat flow over the upflow zones and associated shallow lateral outflow plumes. These systems can show isothermal conditions at depth in the upflow zones that feed shallow outflow plumes and hot springs. The Socorro geothermal system is a prime example of this type of a geothermal prospect. Deeper conductive targets are overlain by relatively thick low permeability sedimentary or volcanoclastic sequences that have relatively, low thermal conductivity and higher temperature gradients. Portions of the San Juan Basin and Rio Grande rift are characterized by this type of geothermal prospect. NM Tech is currently developing a state-wide assessment of New Mexico’s geothermal resources for the New Mexico Energy Conservation and Management Division. We present two finite element models of conductive-convective heat transfer along the Rio Grande Rift and San Juan Basin to evaluate the suitability of these two types of geothermal resources for EGS systems.

  13. Development of Models to Simulate Tracer Behavior in Enhanced Geothermal Systems

    SciTech Connect

    Williams, Mark D.; Vermeul, Vincent R.; Reimus, P. W.; Newell, D.; Watson, Tom B.

    2010-06-01

    A recent report found that power and heat produced from engineered (or enhanced) geothermal systems (EGSs) could have a major impact on the United States while incurring minimal environmental impacts. EGS resources differ from high-grade hydrothermal resources in that they lack sufficient temperature distributions, permeability/porosity, fluid saturation, or recharge of reservoir fluids. Therefore, quantitative characterization of temperature distributions and the surface area available for heat transfer in EGS is necessary for commercial development of geothermal energy. The goal of this project is to provide integrated tracer and tracer interpretation tools to facilitate this characterization. Modeling capabilities are being developed as part of this project to support laboratory and field testing to characterize engineered geothermal systems in single- and multi-well tests using tracers. The objective of this report is to describe the simulation plan and the status of model development for simulating tracer tests for characterizing EGS.

  14. Geophysical, geochemical, and geological investigations of the Dunes geothermal system, Imperial Valley, California

    NASA Technical Reports Server (NTRS)

    Elders, W. A.; Combs, J.; Coplen, T. B.; Kolesar, P.; Bird, D. K.

    1974-01-01

    The Dunes anomaly is a water-dominated geothermal system in the alluvium of the Salton Trough, lacking any surface expression. It was discovered by shallow-temperature gradient measurements. A 612-meter-deep test well encountered several temperature-gradient reversals, with a maximum of 105 C at 114 meters. The program involves surface geophysics, including electrical, gravity, and seismic methods, down-hole geophysics and petrophysics of core samples, isotopic and chemical studies of water samples, and petrological and geochemical studies of the cores and cuttings. The aim is (1) to determine the source and temperature history of the brines, (2) to understand the interaction between the brines and rocks, and (3) to determine the areal extent, nature, origin, and history of the geothermal system. These studies are designed to provide better definition of exploration targets for hidden geothermal anomalies and to contribute to improved techniques of exploration and resource assessment.

  15. NATIONAL GEOTHERMAL DATA SYSTEM: AN EXEMPLAR OF OPEN ACCESS TO DATA

    SciTech Connect

    Blackman, Harold; Blackman, Harold M.; Blackman, Harold M.; Blackman, Harold; Blackman, Harold; Blackman, Harold

    2013-10-01

    The formal launch of National Geothermal Data System (NGDS – www.geothermaldata.org) in 2014 will provide open access to technical geothermal-relevant data from all of the Department of Energy- sponsored geothermal development and research projects and geologic data from all 50 states. By making data easily discoverable and accessible this system will open new exploration opportunities and shorten project development. The prototype data system currently includes multiple data nodes, and nationwide data online and available to the public, indexed through a single catalog under construction at http://search.geothermaldata.org. Data from state geological surveys and partners includes more than 5 million records online, including 1.48 million well headers (oil and gas, water, geothermal), 732,000 well logs, and 314,000 borehole temperatures and is growing rapidly. There are over 250 Web services and another 138 WMS (Web Map Services) registered in the system as of August, 2013. Additional data record is being added by companion projects run by Boise State University, Southern Methodist University, and the USGS. The National Renewable Energy Laboratory is managing the Geothermal Data Repository, an NGDS node that will be a clearinghouse for data from hundreds of DOE-funded geothermal projects. NGDS is built on the US Geoscience Information Network (USGIN) data integration framework, which is a joint undertaking of the USGS and the Association of American State Geologists (AASG). NGDS is fully compliant with the White House Executive Order of May 2013, requiring all federal agencies to make their data holdings publicly accessible online in open source, interoperable formats with common core and extensible metadata. The National Geothermal Data System is being designed, built, deployed, and populated primarily with grants from the US Department of Energy, Geothermal Technologies Office. To keep this operational system sustainable after the original implementation will

  16. National Geothermal Data System: an Exemplar of Open Access to Data

    NASA Astrophysics Data System (ADS)

    Allison, M. L.; Richard, S. M.; Blackman, H.; Anderson, A.

    2013-12-01

    The National Geothermal Data System's (NGDS - www.geothermaldata.org) formal launch in 2014 will provide open access to millions of datasets, sharing technical geothermal-relevant data across the geosciences to propel geothermal development and production. With information from all of the Department of Energy's sponsored development and research projects and geologic data from all 50 states, this free, interactive tool is opening new exploration opportunities and shortening project development by making data easily discoverable and accessible. We continue to populate our prototype functional data system with multiple data nodes and nationwide data online and available to the public. Data from state geological surveys and partners includes more than 5 million records online, including 1.48 million well headers (oil and gas, water, geothermal), 732,000 well logs, and 314,000 borehole temperatures and is growing rapidly. There are over 250 Web services and another 138 WMS (Web Map Services) registered in the system as of August, 2013. Companion projects run by Boise State University, Southern Methodist University, and USGS are adding millions of additional data records. The National Renewable Energy Laboratory is managing the Geothermal Data Repository which will serve as a system node and clearinghouse for data from hundreds of DOE-funded geothermal projects. NGDS is built on the US Geoscience Information Network data integration framework, which is a joint undertaking of the USGS and the Association of American State Geologists (AASG). NGDS is fully compliant with the White House Executive Order of May 2013, requiring all federal agencies to make their data holdings publicly accessible online in open source, interoperable formats with common core and extensible metadata. The National Geothermal Data System is being designed, built, deployed, and populated primarily with grants from the US Department of Energy, Geothermal Technologies Office. To keep this operational

  17. Theoretical prediction of phase relations among aqueous solutions and minerals: Salton Sea geothermal system

    NASA Astrophysics Data System (ADS)

    Bird, Dennis K.; Norton, Denis L.

    1981-09-01

    Thermodynamic calculations of compositional relations among aqueous solutions and minerals in the system Na2O-K2O-CaO-MgO-Fe2O3 Al2O3-SiO2-H2O-CO2 HCl at pressures and temperatures corresponding to liquid-vapor equilibrium of H2O permit quantitative description and interpretation of phase relations among rock forming minerals and aqueous solutions in magma-hydrothermal systems. The extensive data base on the Salton Sea geothermal system provides an exemplary case for predicting the chemical characteristics of geothermal fluids associated with metasomatic mineral zones observed in deep drillhole samples. Near the Elmore No. 1 well aqueous species activity ratios of {aNa+}/{aH+} and {aK+}/{aH+} vary several tenths of a log unit with increasing depth and temperature from ∼ 0.6 km and ∼250°C to ∼ 2.2 km and ∼350°C, whereas {aCa2+}/{a2H+} decreases ∼ 2 orders of magnitude for a comparable range in depth and temperature. The fugacity of CO2 gas is ∼1.5-6 bars at ≲ 310°C. Calculated values of aSio2(aq), {aNa+}/{aK+}, {aCa2+}/{aMg2+} and fCO2(g), in the fluid phase coexisting with observed mineralogic phase relations are in remarkably close agreement with measured solute concentrations in geothermal fluids produced from deep drillholes near the Salton Sea. Hydrolysis reactions representing observed phase relations and written with alkali and alkaline earth cations as products have negative standard molal enthalpies (ΔH0P,T,r) and volumes (ΔV0P,T,r) of reactions; consequently, {aNa+}/{aH+}, {aK+}/{aH+}, {aCa2+}/{a2H+}, and {aMg2+}/{a2H+} decrease with increasing temperature at constant pressure, but increase with increasing pressure at constant temperature. An approximate linear relationship exists among these activity ratios and the reciprocal of absolute temperatures because ΔH0P,T,r varies only slightly with increasing temperature at ≲ 250 to 300°C. However, at ≳300°C, ΔH0P,T,r and ΔV0P,T,R decrease dramatically as a consequence of extrema in

  18. Numerical Analysis of Combined Well and Open-Closed Loops Geothermal (CWG) Systems

    NASA Astrophysics Data System (ADS)

    Park, Yu-Chul

    2016-04-01

    Open-loop geothermal heat pump (GHP) system and closed-loop heat pump systems have been used in Korea to reduce emission of greenhouse gases such as carbon dioxide (CO2). The GHP systems have the pros and cons, for example, the open-loop GHP system is good energy-efficient and the closed-loop GHP system requires minimum maintenance costs. The open-loop GHP system can be used practically only with large amount of groundwater supply. The closed-loop GHP system can be used with high costs of initial installation. The performance and efficiency of the GHP system depend on the characteristics of the GHP system itself in addition to the geologic conditions. To overcome the cons of open-loop or closed-loop GHP system, the combined well and open-closed loops geothermal (CWG) system was designed. The open-loop GHP system is surrounded with closed-loop GHP systems in the CWG system. The geothermal energy in closed-loop GHP systems is supplied by the groundwater pumped by the open-loop GHP system. In this study, 2 different types of the CWG systems (small aperture hybrid CWG system and large aperture CWG system) are estimated using numerical simulation models in the aspect of energy efficiency. This work was supported by the New & Renewable Energy Core Technology Program of the Korea Institute of Energy Technology Evaluation and Planning (KETEP), granted financial resource from the Ministry of Trade, Industry & Energy, Republic of Korea. (No.20153030111120).

  19. 3-Dimensional Geologic Modeling Applied to the Structural Characterization of Geothermal Systems: Astor Pass, Nevada, USA

    SciTech Connect

    Siler, Drew L; Faulds, James E; Mayhew, Brett

    2013-04-16

    Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to broad-scale geothermal circulation is crucial to both the mitigation of the costs of geothermal exploration (especially drilling) and to the identification of geothermal systems that have no surface expression (blind systems). 3-dimensional geologic modeling is a tool that can elucidate the specific stratigraphic intervals and structural geometries that host geothermal reservoirs. Astor Pass, NV USA lies just beyond the northern extent of the dextral Pyramid Lake fault zone near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present. Previous studies at Astor Pass identified a blind geothermal system controlled by the intersection of west-northwest and north-northwest striking dextral-normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting a maximum reservoir temperature of 130°C. A 3-dimensional model was constructed based on detailed geologic maps and cross-sections, 2-dimensional seismic data, and petrologic analysis of the cuttings from three wells in order to further constrain the structural setting. The model reveals the specific geometry of the fault interaction area at a level of detail beyond what geologic maps and cross-sections can provide.

  20. A Simple Model for Probabilistic Seismic Hazard Analysis of Induced Seismicity Associated With Deep Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Schlittenhardt, Joerg; Spies, Thomas; Kopera, Juergen; Morales Aviles, Wilhelm

    2014-05-01

    In the research project MAGS (Microseismic activity of geothermal systems) funded by the German Federal Ministry of Environment (BMU) a simple model was developed to determine seismic hazard as the probability of the exceedance of ground motion of a certain size. Such estimates of the annual frequency of exceedance of prescriptive limits of e.g. seismic intensities or ground motions are needed for the planning and licensing, but likewise for the development and operation of deep geothermal systems. For the development of the proposed model well established probabilistic seismic hazard analysis (PSHA) methods for the estimation of the hazard for the case of natural seismicity were adapted to the case of induced seismicity. Important differences between induced and natural seismicity had to be considered. These include significantly smaller magnitudes, depths and source to site distances of the seismic events and, hence, different ground motion prediction equations (GMPE) that had to be incorporated to account for the seismic amplitude attenuation with distance as well as differences in the stationarity of the underlying tectonic and induced processes. Appropriate GMPE's in terms of PGV (peak ground velocity) were tested and selected from the literature. The proposed model and its application to the case of induced seismicity observed during the circulation period (operation phase of the plant) at geothermal sites in Germany will be presented. Using GMPE's for PGV has the advantage to estimate hazard in terms of velocities of ground motion, which can be linked to engineering regulations (e.g. German DIN 4150) which give prescriptive standards for the effects of vibrations on buildings and people. It is thus possible to specify the probability of exceedance of such prescriptive standard values and to decide whether they can be accepted or not. On the other hand hazard curves for induced and natural seismicity can be compared to study the impact at a site. Preliminary

  1. Microbial diversity in an anaerobic digester with biogeographical proximity to geothermally active region.

    PubMed

    Mahajan, Rishi; Nikitina, Anna; Nozhevnikova, Alla; Goel, Gunjan

    2016-11-01

    Anaerobic digestion of agricultural biomass or wastes can offer renewable energy, to help meet the rise in energy demands. The performance of an anaerobic digester considerably depends upon the complex interactions between bacterial and archaeal microbiome, which is greatly influenced by environmental factors. In the present study, we evaluate a microbial community of digester located at two different geographical locations, to understand whether the biogeographical proximity of a digester to a geothermally active region has any influence on microbial composition. The comparative microbial community profiling, highlights coexistence of specific bacterial and archaeal representatives (especially, Prosthecochloris sp., Conexibacter sp., Crenarchaeota isolate (Caldivirga sp.), Metallosphaera sp., Pyrobaculum sp. and Acidianus sp.) in a digester with close proximity to geothermally active region (Site I) and their absence in a digester located far-off from geothermally active region (Site II). A Sörensen's index of similarity of 83.33% and 66.66% for bacterial and archaeal community was observed in both the reactors, respectively.

  2. Microbial diversity in an anaerobic digester with biogeographical proximity to geothermally active region.

    PubMed

    Mahajan, Rishi; Nikitina, Anna; Nozhevnikova, Alla; Goel, Gunjan

    2016-11-01

    Anaerobic digestion of agricultural biomass or wastes can offer renewable energy, to help meet the rise in energy demands. The performance of an anaerobic digester considerably depends upon the complex interactions between bacterial and archaeal microbiome, which is greatly influenced by environmental factors. In the present study, we evaluate a microbial community of digester located at two different geographical locations, to understand whether the biogeographical proximity of a digester to a geothermally active region has any influence on microbial composition. The comparative microbial community profiling, highlights coexistence of specific bacterial and archaeal representatives (especially, Prosthecochloris sp., Conexibacter sp., Crenarchaeota isolate (Caldivirga sp.), Metallosphaera sp., Pyrobaculum sp. and Acidianus sp.) in a digester with close proximity to geothermally active region (Site I) and their absence in a digester located far-off from geothermally active region (Site II). A Sörensen's index of similarity of 83.33% and 66.66% for bacterial and archaeal community was observed in both the reactors, respectively. PMID:26934210

  3. Near-Surface CO2 Monitoring And Analysis To Detect Hidden Geothermal Systems

    SciTech Connect

    Lewicki, Jennifer L.; Oldenburg, Curtis M.

    2005-01-19

    ''Hidden'' geothermal systems are systems devoid of obvious surface hydrothermal manifestations. Emissions of moderate-to-low solubility gases may be one of the primary near-surface signals from these systems. We investigate the potential for CO2 detection and monitoring below and above ground in the near-surface environment as an approach to exploration targeting hidden geothermal systems. We focus on CO2 because it is the dominant noncondensible gas species in most geothermal systems and has moderate solubility in water. We carried out numerical simulations of a CO2 migration scenario to calculate the magnitude of expected fluxes and concentrations. Our results show that CO2 concentrations can reach high levels in the shallow subsurface even for relatively low geothermal source CO2 fluxes. However, once CO2 seeps out of the ground into the atmospheric surface layer, winds are effective at dispersing CO2 seepage. In natural ecological systems in the absence of geothermal gas emissions, near-surface CO2 fluxes and concentrations are predominantly controlled by CO2 uptake by photosynthesis, production by root respiration, microbial decomposition of soil/subsoil organic matter, groundwater degassing, and exchange with the atmosphere. Available technologies for monitoring CO2 in the near-surface environment include the infrared gas analyzer, the accumulation chamber method, the eddy covariance method, hyperspectral imaging, and light detection and ranging. To meet the challenge of detecting potentially small-magnitude geothermal CO2 emissions within the natural background variability of CO2, we propose an approach that integrates available detection and monitoring techniques with statistical analysis and modeling strategies. The proposed monitoring plan initially focuses on rapid, economical, reliable measurements of CO2 subsurface concentrations and surface fluxes and statistical analysis of the collected data. Based on this analysis, are as with a high probability

  4. Deep geothermal resources and energy: Current research and developments

    NASA Astrophysics Data System (ADS)

    Manzella, A.; Milsch, H.; Hahne, B.; van Wees, J. D.; Bruhn, D.

    2012-04-01

    Energy from deep geothermal resources plays an increasing role in many European countries in their efforts to increase the proportion of renewables in their energy portfolio. Deep geothermal heat and electric power have a high load factor, are sustainable and environmentally friendly. However, the safe, sustainable, and economic development of deep geothermal resources, also in less favourable regions, faces a number of issues requiring substantial research efforts: (1) The probability of finding an unknown geothermal reservoir has to be improved. (2) Drilling methods have to be better adapted and developed to the specific needs of geothermal development. (3) The assessment of the geothermal potential should provide more reliable and clear guidelines for the development. (4) Stimulation methods for enhanced geothermal systems (EGS) have to be refined to increase the success rate and reduce the risk associated with induced seismicity. (5) Operation and maintenance in aggressive geothermal environments require specific solutions for corrosion and scaling problems. (6) Last but not least, emerging activities to harness energy from supercritical reservoirs would make significant progress with qualified input from research. In particular, sedimentary basins like e.g. the North German and Polish Basin, the Pannonian Basin, the Po Valley, the Bavarian Molasse Basin or the Upper Rhine Graben have a high geothermal potential, even if geothermal gradients are moderate. We will highlight projects that aim at optimizing exploration, characterization, and modeling prior to drilling and at a better understanding of physical, hydraulic and chemical processes during operation of a geothermal power plant. This includes geophysical, geological and geochemical investigations regarding potential geothermal reservoirs in sedimentary basins, as well as modelling of geothermally relevant reservoir parameters that influence the potential performance and long-term behavior of a future

  5. Selected data for low-temperature (less than 90{sup 0}C) geothermal systems in the United States: reference data for US Geological Survey Circular 892

    SciTech Connect

    Reed, M.J.; Mariner, R.H.; Brook, C.A.; Sorey, M.L.

    1983-12-15

    Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

  6. Selected data for low-temperature (less than 90 degrees C) geothermal systems in the United States; reference data for U.S. Geological Survey Circular 892

    USGS Publications Warehouse

    Reed, Marshall J.; Mariner, R.H.; Brook, C.A.; Sorey, M.L.

    1983-01-01

    Supporting data are presented for the 1982 low-temperature geothermal resource assessment of the United States. Data are presented for 2072 geothermal sites which are representative of 1168 low-temperature geothermal systems identified in 26 States. The low-temperature geothermal systems consist of 978 isolated hydrothermal-convection systems, 148 delineated-area hydrothermal-convection systems, and 42 delineated-area conduction-dominated systems. The basic data and estimates of reservoir conditions are presented for each geothermal system, and energy estimates are given for the accessible resource base, resource, and beneficial heat for each isolated system.

  7. Hydrochemistry and geothermometrical modeling of low-temperature Panticosa geothermal system (Spain)

    NASA Astrophysics Data System (ADS)

    Asta, Maria P.; Gimeno, Maria J.; Auqué, Luis F.; Gómez, Javier; Acero, Patricia; Lapuente, Pilar

    2012-08-01

    The chemical characteristics of the low-temperature geothermal system of Panticosa (Spain) were investigated in order to determine the water temperature at the reservoir and to identify the main geochemical processes that affect the water composition during the ascent of the thermal waters. In general, the studied waters are similar to other geothermal systems in the Pyrenees, belonging to the group of granite-related alkaline thermal waters (high pH, low total dissolved solids, very low magnesium concentration, and sodium as the dominant cation). According to the alkaline pH of these waters, they have a very low CO2 partial pressure, bicarbonate is the dominant anion and silica is partially ionized as H3SiO4-. The unusually active acid-base pairs (HCO3-/CO32 - and, mainly, H4SiO4/H3SiO4-) act as homogeneous pH buffers and contribute to the total alkalinity in these alkaline waters. On the basis of the study of the conservative elements, a mixing process between a hot and a cold end-member has been identified. Additionally, in order to determinate the water temperature at the reservoir, several geothermometric techniques have been applied, including both geothermometrical modeling and classical geothermometrical calculations. The geothermometrical modeling seems to indicate that thermal waters re-equilibrate with respect to calcite and kaolinite during their ascent to the surface. Modeling results suggest that these thermal waters would be in equilibrium with respect to albite, K-feldspar, quartz, calcite, kaolinite and zoisite at a similar temperature of 90 ± 20 °C in the reservoir, which is in good agreement with the results obtained by applying the classical geothermometers.

  8. Numerical modeling of geothermal heat pump system: evaluation of site specific groundwater thermal impact

    NASA Astrophysics Data System (ADS)

    Pedron, Roberto; Sottani, Andrea; Vettorello, Luca

    2014-05-01

    A pilot plant using a geothermal open-loop heat pump system has been realized in the city of Vicenza (Northern Italy), in order to meet the heating and cooling needs of the main monumental building in the historical center, the Palladian Basilica. The low enthalpy geothermal system consists of a pumping well and a reinjection well, both intercepting the same confined aquifer; three other monitoring wells have been drilled and then provided with water level and temperature dataloggers. After about 1 year and a half of activity, during a starting experimental period of three years, we have now the opportunity to analyze long term groundwater temperature data series and to evaluate the numerical modeling reliability about thermal impact prediction. The initial model, based on MODFLOW and SHEMAT finite difference codes, has been calibrated using pumping tests and other field investigations data, obtaining a valid and reliable groundwater flow simulation. But thermal parameters, such as thermal conductivity and volumetric heat capacity, didn't have a site specific direct estimation and therefore they have been assigned to model cells referring to bibliographic standards, usually derived from laboratory tests and barely representing real aquifer properties. Anyway preliminary heat transport results have been compared with observed temperature trends, showing an efficient representation of the thermal plume extension and shape. The ante operam simulation could not consider heat pump real utilization, that happened to be relevantly different from the expected project values; so the first numerical model could not properly simulate the groundwater temperature evolution. Consequently a second model has been implemented, in order to calibrate the mathematical simulation with monitored groundwater temperature datasets, trying to achieve higher levels of reliability in heat transport phenomena interpretation. This second step analysis focuses on aquifer thermal parameters

  9. Geothermal Systems of the Great Basin and U.S. Geological Survey Plans for a Regional Resource Assessment

    USGS Publications Warehouse

    Williams, C.F.

    2002-01-01

    Based on current projections, the United States faces the need to increase its electrical power generating capacity by 40% (approximately 300,000 Megawatts-electrical or MWe) over the next 20 years (Energy Information Administration, EIA - Department of Energy). A critical question for the near future is the extent to which geothermal resources can contribute to this increasing demand for electricity. Geothermal energy constitutes one of the nation's largest sources of renewable and environmentally benign electrical power, yet the installed capacity of 2860 MWe falls far short of estimated geothermal resources. This is particularly true for the Great Basin region of the western United States, which has an installed capacity of about 500 MWe, much lower than the 7500 MWe resource estimated by the U.S. Geological Survey (USGS) in the late 1970s. The reasons for the limited development of geothermal power are varied, but political, economic and technological developments suggest the time is ripe for a new assessment effort. Technologies for power production from geothermal systems and scientific understanding of geothermal resource occurrence have improved dramatically in recent years. The primary challenges facing geothermal resource studies are (1) understanding the thermal, chemical and mechanical processes that lead to the colocation of high temperatures and high permeabilities necessary for the formation of geothermal systems and (2) developing improved techniques for locating, characterizing and exploiting these systems. Starting in the fall of 2002, the USGS will begin work with institutions funded by the Department of Energy's (DOE) Geothermal Research Program to investigate the nature and extent of geothermal systems in the Great Basin and to produce an updated assessment of available geothermal resources.

  10. Temperatures, heat flow, and water chemistry from drill holes in the Raft River geothermal system, Cassia County, Idaho

    SciTech Connect

    Nathenson, M.; Urban, T.C.; Diment, W.H.; Nehring, N.L.

    1980-01-01

    The Raft River area of Idaho contains a geothermal system of intermediate temperatures (approx. = 150/sup 0/C) at depths of about 1.5 km. Outside of the geothermal area, temperature measurements in three intermediate-depth drill holes (200 to 400 m) and one deep well (1500 m) indicate that the regional conductive heat flow is about 2.5 ..mu..cal/cm/sup 2/ sec or slightly higher and that temperature gradients range from 50/sup 0/ to 60/sup 0/C/km in the sediments, tuffs, and volcanic debris that fill the valley. Within and close to the geothermal system, temperature gradients in intermediate-depth drill holes (100 to 350 m) range from 120/sup 0/ to more than 600/sup 0/C/km, the latter value found close to an artesian hot well that was once a hot spring. Temperatures measured in three deep wells (1 to 2 km) within the geothermal area indicate that two wells are in or near an active upflow zone, whereas one well shows a temperature reversal. Assuming that the upflow is fault controlled, the flow is estimated to be 6 liter/sec per kilometer of fault length. From shut-in pressure data and the estimated flow, the permeability times thickness of the fault is calculated to be 2.4 darcy m. Chemical analyses of water samples from old flowing wells, recently completed intermediate-depth drill holes, and deep wells show a confused pattern. Geothermometer temperatures of shallow samples suggest significant re-equilibration at temperatures below those found in the deep wells. Silica geothermometer temperatures of water samples from the deep wells are in reasonable agreement with measured temperatures, whereas Na-K-Ca temperatures are significantly higher than measured temperatures. The chemical characteristics of the water, as indicated by chloride concentration, are extremely variable in shallow and deep samples. Chloride concentrations of the deep samples range from 580 to 2200 mg/kg.

  11. HIGH-TEMPERATURE GEOTHERMAL RESOURCES IN HYDROTHERMAL CONVECTION SYSTEMS IN THE UNITED STATES.

    USGS Publications Warehouse

    Nathenson, Manuel

    1983-01-01

    The calculation of high-temperature geothermal resources ( greater than 150 degree C) in the United States has been done by estimating the temperature, area, and thickness of each identified system. These data, along with a general model for recoverability of geothermal energy and a calculation that takes account of the conversion of thermal energy to electricity, yielded an estimate of 23,000 MW//e for 30 years. The undiscovered component was estimated based on multipliers of the identified resource as either 72,000 or 127,000 MW//e for 30 years depending on the model chosen for the distribution of undiscovered energy as a function of temperature.

  12. Geothermal energy in Nevada

    SciTech Connect

    Not Available

    1980-01-01

    The nature of goethermal resources in Nevada and resource applications are discussed. The social and economic advantages of utilizing geothermal energy are outlined. Federal and State programs established to foster the development of geothermal energy are discussed. The names, addresses, and phone numbers of various organizations actively involved in research, regulation, and the development of geothermal energy are included. (MHR)

  13. A materials and equipment review of selected US geothermal district heating systems

    SciTech Connect

    Rafferty, K.D.

    1989-07-01

    This collection of information was assembled for the benefit of future geothermal system designers and existing system operators. It is intended to provide insight into the experience gained from the operation of 13 major geothermal systems over the past several years. Each chapter contains six or seven sections depending upon the type of system: introduction, production facilities, distribution, customer connections, metering and disposal. Some chapters, covering systems which incorporate a closed distribution design include a section on the central mechanical room. Each section details the original equipment and materials installed in that portion of the system. Following each section is a discussion of the subsequent problems, solutions and modifications relating to the equipment. The extent to which information was available varied from system to system. This is reflected in the length and level of detail of the chapters.

  14. Active Management of Integrated Geothermal-CO2 Storage Reservoirs in Sedimentary Formations: Data used in Geosphere Journal Article

    DOE Data Explorer

    Thomas A. Buscheck

    2015-06-01

    This data submission is for Phase 2 of Active Management of Integrated Geothermal-CO2 Storage Reservoirs in Sedimentary Formations, which focuses on multi-fluid (CO2 and brine) geothermal energy production and diurnal bulk energy storage in geologic settings that are suitable for geologic CO2 storage. This data submission includes all data used in the Geosphere Journal article by Buscheck et al (2016). All assumptions are discussed in that article.

  15. National Geothermal Data System (USA): an Exemplar of Open Access to Data

    NASA Astrophysics Data System (ADS)

    Allison, M. Lee; Richard, Stephen; Blackman, Harold; Anderson, Arlene; Patten, Kim

    2014-05-01

    The National Geothermal Data System's (NGDS - www.geothermaldata.org) formal launch in April, 2014 will provide open access to millions of data records, sharing -relevant geoscience and longer term to land use data to propel geothermal development and production. NGDS serves information from all of the U.S. Department of Energy's sponsored development and research projects and geologic data from all 50 states, using free and open source software. This interactive online system is opening new exploration opportunities and potentially shortening project development by making data easily discoverable, accessible, and interoperable. We continue to populate our prototype functional data system with multiple data nodes and nationwide data online and available to the public. Data from state geological surveys and partners includes more than 6 million records online, including 1.72 million well headers (oil and gas, water, geothermal), 670,000 well logs, and 497,000 borehole temperatures and is growing rapidly. There are over 312 interoperable Web services and another 106 WMS (Web Map Services) registered in the system as of January, 2014. Companion projects run by Southern Methodist University and U.S. Geological Survey (USGS) are adding millions of additional data records. The DOE Geothermal Data Repository, currently hosted on OpenEI, is a system node and clearinghouse for data from hundreds of U.S. DOE-funded geothermal projects. NGDS is built on the US Geoscience Information Network (USGIN) data integration framework, which is a joint undertaking of the USGS and the Association of American State Geologists (AASG). NGDS complies with the White House Executive Order of May 2013, requiring all federal agencies to make their data holdings publicly accessible online in open source, interoperable formats with common core and extensible metadata. The National Geothermal Data System is being designed, built, deployed, and populated primarily with support from the US

  16. Precision gravity network for monitoring the Lassen geothermal system, Northern California

    USGS Publications Warehouse

    Jachens, Robert C.; Saltus, R.W.

    1983-01-01

    A precision gravity network consisting of approximately 50 stations was established to monitor the Lassen geothermal system. The network was surveyed during the summer of 1982 and tied to a similar network established in 1981. Measurements yielded relative gravity values at the network stations with average uncertainties of 0.007 mGal (1 computed standard error).

  17. Demonstration of a Variable Phase Turbine Power System for Low Temperature Geothermal Resources

    SciTech Connect

    Hays, Lance G

    2014-07-07

    A variable phase turbine assembly will be designed and manufactured having a turbine, operable with transcritical, two-phase or vapor flow, and a generator – on the same shaft supported by process lubricated bearings. The assembly will be hermetically sealed and the generator cooled by the refrigerant. A compact plate-fin heat exchanger or tube and shell heat exchanger will be used to transfer heat from the geothermal fluid to the refrigerant. The demonstration turbine will be operated separately with two-phase flow and with vapor flow to demonstrate performance and applicability to the entire range of low temperature geothermal resources. The vapor leaving the turbine is condensed in a plate-fin refrigerant condenser. The heat exchanger, variable phase turbine assembly and condenser are all mounted on single skids to enable factory assembly and checkout and minimize installation costs. The system will be demonstrated using low temperature (237F) well flow from an existing large geothermal field. The net power generated, 1 megawatt, will be fed into the existing power system at the demonstration site. The system will demonstrate reliable generation of inexpensive power from low temperature resources. The system will be designed for mass manufacturing and factory assembly and should cost less than $1,200/kWe installed, when manufactured in large quantities. The estimated cost of power for 300F resources is predicted to be less than 5 cents/kWh. This should enable a substantial increase in power generated from low temperature geothermal resources.

  18. 36Cl/Cl ratios in geothermal systems: preliminary measurements from the Coso Field

    SciTech Connect

    Nimz, G.J.; Moore, J.N.; Kasameyer, P.W.

    1997-07-01

    The {sub 36}Cl/Cl isotopic composition of chlorine in geothermal systems can be a useful diagnostic tool in characterizing hydrologic structure, in determining the origins and age of waters within the systems, and in differentiating the sources of chlorine (and other solutes) in the thermal waters. The {sub 36}Cl/Cl values for several geothermal water samples and reservoir host rock samples from the Coso, California geothermal field have been measured for these purposes. The results indicate that most of the chlorine is not derived from the dominant granitoid that host the geothermal system. If the chlorine was originally input into the Coso subsurface through meteoric recharge, that input occurred at least 1-1.25 million years ago. The results suggest that the thermal waters could be connate waters derived from sedimentary formations, presumably underlying and adjacent top the granitic rocks, which have recently migrated into the host rocks. Alternatively, most of the chlorine but not the water, may have recently input into the system from magmatic sources. In either case, the results indicate that most of the chlorine in the thermal waters has existed within the granitoid host rocks for no more than about 100,00-200,00 years. this residence time for the chlorine is similar to residence times suggested by other researchers for chlorine in deep groundwaters of the Mono Basin north of the Coso field.

  19. Comparison of Selective Culturing and Biochemical Techniques for Measuring Biological Activity in Geothermal Process Fluids

    SciTech Connect

    Pryfogle, Peter Albert

    2000-09-01

    For the past three years, scientists at the Idaho National Engineering and Environmental Laboratory have been conducting studies aimed at determining the presence and influence of bacteria found in geothermal plant cooling water systems. In particular, the efforts have been directed at understanding the conditions that lead to the growth and accumulation of biomass within these systems, reducing the operational and thermal efficiency. Initially, the methods selected were based upon the current practices used by the industry and included the collection of water quality parameters, the measurement of soluble carbon, and the use of selective medial for the determination of the number density of various types of organisms. This data has been collected on a seasonal basis at six different facilities located at the Geysers’ in Northern California. While this data is valuable in establishing biological growth trends in the facilities and providing an initial determination of upset or off-normal conditions, more detailed information about the biological activity is needed to determine what is triggering or sustaining the growth in these facilities in order to develop improved monitoring and treatment techniques. In recent years, new biochemical approaches, based upon the analyses of phospholipid fatty acids and DNA recovered from environmental samples, have been developed and commercialized. These techniques, in addition to allowing the determination of the quantity of biomass, also provide information on the community composition and the nutritional status of the organisms. During the past year, samples collected from the condenser effluents of four of the plants from The Geysers’ were analyzed using these methods and compared with the results obtained from selective culturing techniques. The purpose of this effort was to evaluate the cost-benefit of implementing these techniques for tracking microbial activity in the plant study, in place of the selective culturing

  20. Human Health Science Building Geothermal Heat Pump Systems

    SciTech Connect

    Leidel, James

    2014-12-22

    The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

  1. Method for resisting corrosion in geothermal fluid handling systems

    SciTech Connect

    Love, W.W.; Cron, C.J.

    1988-05-24

    A method for resisting corrosion while conducting a flow of hot, corrosive geothermal fluid is described comprising the steps of: (a) forming a fluid conducting element of a beta and alpha titanium-base product produced by heating to form a metastable beta titantium matrix, and thereafter heat treating the matrix to form sufficient alpha phase therein providing an increase in ultimate tensile strength of at least about 10,000 psi over that of the matrix before the heat treating, the beta and alpha titantium-base product so formed having an average valence electron density of between about 4.15 and about 4.35. The composition consisting essentially of: (i) a total of between about 2 and about 10 weight percent of one or more beta eutectoid elements; (ii) between about 4 and about 10 weight percent of vanadium; (iii) between about 3 and about 6 weight percent of molybdenum; (iv) between about 2 and about 5 weight percent of aluminum; and (v) the balance titanium; and (b) following the geothermal fluid through the fluid conducting element.

  2. Investigating ultra high-enthalpy geothermal systems: a collaborative initiative to promote scientific opportunities

    NASA Astrophysics Data System (ADS)

    Elders, W. A.; Nielson, D.; Schiffman, P.; Schriener, A., Jr.

    2014-12-01

    Scientists, engineers, and policy makers gathered at a workshop in the San Bernardino Mountains of southern California in October 2013 to discuss the science and technology involved in developing high-enthalpy geothermal fields. A typical high-enthalpy geothermal well between 2000 and 3000 m deep produces a mixture of hot water and steam at 200-300 °C that can be used to generate about 5-10 MWe of electric power. The theme of the workshop was to explore the feasibility and economic potential of increasing the power output of geothermal wells by an order of magnitude by drilling deeper to reach much higher pressures and temperatures. Development of higher enthalpy geothermal systems for power production has obvious advantages; specifically higher temperatures yield higher power outputs per well so that fewer wells are needed, leading to smaller environmental footprints for a given size of power plant. Plans for resource assessment and drilling in such higher enthalpy areas are already underway in Iceland, New Zealand, and Japan. There is considerable potential for similar developments in other countries that already have a large production of electricity from geothermal steam, such as Mexico, the Philippines, Indonesia, Italy, and the USA. However drilling deeper involves technical and economic challenges. One approach to mitigating the cost issue is to form a consortium of industry, government and academia to share the costs and broaden the scope of investigation. An excellent example of such collaboration is the Iceland Deep Drilling Project (IDDP), which is investigating the economic feasibility of producing electricity from supercritical geothermal reservoirs, and this approach could serve as model for future developments elsewhere. A planning committee was formed to explore creating a similar initiative in the USA.

  3. Climate change and geothermal ecosystems: natural laboratories, sentinel systems, and future refugia.

    PubMed

    O'Gorman, Eoin J; Benstead, Jonathan P; Cross, Wyatt F; Friberg, Nikolai; Hood, James M; Johnson, Philip W; Sigurdsson, Bjarni D; Woodward, Guy

    2014-11-01

    Understanding and predicting how global warming affects the structure and functioning of natural ecosystems is a key challenge of the 21st century. Isolated laboratory and field experiments testing global change hypotheses have been criticized for being too small-scale and overly simplistic, whereas surveys are inferential and often confound temperature with other drivers. Research that utilizes natural thermal gradients offers a more promising approach and geothermal ecosystems in particular, which span a range of temperatures within a single biogeographic area, allow us to take the laboratory into nature rather than vice versa. By isolating temperature from other drivers, its ecological effects can be quantified without any loss of realism, and transient and equilibrial responses can be measured in the same system across scales that are not feasible using other empirical methods. Embedding manipulative experiments within geothermal gradients is an especially powerful approach, informing us to what extent small-scale experiments can predict the future behaviour of real ecosystems. Geothermal areas also act as sentinel systems by tracking responses of ecological networks to warming and helping to maintain ecosystem functioning in a changing landscape by providing sources of organisms that are preadapted to different climatic conditions. Here, we highlight the emerging use of geothermal systems in climate change research, identify novel research avenues, and assess their roles for catalysing our understanding of ecological and evolutionary responses to global warming.

  4. Integrated mineralogical and fluid inclusion study of the Coso geothermal systems, California

    SciTech Connect

    Lutz, Susan J.; Moore, Joseph N.; Copp, John F.

    1996-01-24

    Coso is one of several high-temperature geothermal systems on the margins of the Basin and Range province that is associated with recent volcanic activity. This system, which is developed entirely in fractured granitic and metamorphic rocks, consists of a well-defined thermal plume that originates in the southern part of the field and then flows upward and laterally to the north. Fluid inclusion homogenization temperatures and salinities demonstrate that cool, low salinity ground waters were present when the thermal plume was emplaced. Dilution of the thermal waters occurred above and below the plume producing strong gradients in their compositions. In response to heating and mixing, clays and carbonate minerals precipitated, sealing the fractures along the margins of the reservoir and strongly influencing its geometry. The alteration mineralogy varies systematically with depth and temperature. Based on the clay mineralogy, three zones can be recognized: the smectite zone, the illite-smectite zone, and the illite zone. The smectite zone thickens from the north to south and is characterized by smectite, kaolin, stilbite and a variety of carbonate minerals. The illite-smectite zone contains mixed-layer clays and also thickens to the south. The deepest zone (the illite zone) contains illite, chlorite, epidote, and wairakite. Quartz and calcite veins occur in all three zones. Comparison of mineral and fluid inclusion based temperatures demonstrates that cooling has occurred along the margins of the thermal system but that the interior of the system is still undergoing heating.

  5. Monitoring and mapping of hydrogen sulphide emissions across an active geothermal field: Rotorua, New Zealand

    NASA Astrophysics Data System (ADS)

    Horwell, C. J.; Patterson, J. E.; Gamble, J. A.; Allen, A. G.

    2005-01-01

    Hydrogen sulphide (H 2S) is one of a number of gaseous species associated with geothermal activity in the Taupo Volcanic Zone (TVZ), New Zealand. The city of Rotorua is located within Rotorua Caldera in the TVZ and is one of the few urban areas in the world where a large population (>60,000 people) is frequently exposed to geothermal emissions. In order to evaluate the health hazard from long-term exposure to H 2S being emitted from the Rotorua geothermal field, a passive sampler has been developed to measure concentrations of H 2S at many locations across the city simultaneously. In contrast to other passive or pump-based samplers, the sampler is inexpensive, easily mass-manufactured, and involves the reaction of H 2S with silver halide contained in treated photographic paper. H 2S-exposed paper shows a distinct colour change from white to dark brown as H 2S concentrations increase and is sensitive to concentrations between ≪30 and around 1000 ppb. Rotorua city can be divided into three regions—an area of low H 2S concentration in the west, a 'corridor' of high concentrations running north-south through the city centre where H 2S is being emitted, and an area of medium concentration to the east which is influenced by the prevailing wind direction, creating a plume from the central corridor. The data give new insight into the subsurface routes of degassing in the Rotorua geothermal field, by showing the surface expression of the main upflow zone and the direction of the conjectured faulting below.

  6. Deep Groundwater Circulation within Crystalline Basement Rocks and the Role of Hydrologic Windows in the Formation of the Truth or Consequences, New Mexico Low-Temperature Geothermal System

    NASA Astrophysics Data System (ADS)

    Pepin, J.; Person, M. A.; Phillips, F. M.; Kelley, S.; Timmons, S.; Owens, L.; Witcher, J. C.; Gable, C. W.

    2014-12-01

    Hot Springs are common in amagmatic settings, but the mechanisms of heating are often obscure. We have investigated the origin of the Truth or Consequences, New Mexico low-temperature (~ 41 °C) hot springs in the southern Rio Grande rift. We tested two mechanisms that could account for the geothermal anomaly. The first scenario is that the anomaly is the result of lateral forced convection associated with a gently-dipping carbonate aquifer. The second scenario is that high permeability of crystalline basement rocks permits circulation of groundwater down to depths of 8 km prior to discharging in Truth or Consequences. To test these hypotheses, we constructed a two-dimensional hydrothermal model of the region using FEMOC. Model parameters were constrained by calibrating to measured temperatures, specific discharge rates and groundwater residence times. We collected 16 temperature profiles, 11 geochemistry samples and 6 carbon-14 samples within the study area. The geothermal waters are Na+/Cl- dominated and have apparent groundwater ages ranging from 5,500 to 11,500 years. Hot Springs geochemistry is consistent with water/rock interaction in a silicate geothermal reservoir, rather than a carbonate system. Peclet-number analysis of temperature profiles suggests specific discharge rates beneath Truth or Consequences range from 2 to 4 m/year. Geothermometry indicates maximum reservoir temperatures are around 167 °C. We were able to reasonably reproduce observed measurements using the permeable-basement scenario (10-12 m2). The carbonate-aquifer scenario failed to match observations. Our findings imply that the Truth or Consequences geothermal system formed as a result of deep groundwater circulation within permeable crystalline basement rocks. Focused geothermal discharge is the result of localized faulting, which has created a hydrologic window through a regional confining unit. In tectonically active areas, deep groundwater circulation within fractured crystalline

  7. Geothermal direct-heat utilization assistance. Quarterly project progress report, January--March 1996

    SciTech Connect

    1996-05-01

    This report summarizes geothermal technical assistance, R&D, and technology transfer activities of the Geo-Heat Center. It describes 95 contacts with parties during this period related to technical assistance with goethermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics, and resources. Research activities are summarized on geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include publication of a geothermal direct use Bulletin, dissemination of information, goethermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  8. Final report. Geothermal Energy Program: Information dissemination, public outreach, and technical analysis activities. April 1, 1999 to December 31, 2001. USDOE Grant No. DE-FG01-99-EE35098

    SciTech Connect

    Lund, John W.

    2002-03-22

    This is the final report of the accomplishments of the geothermal energy program: information dissemination, public outreach, and technical analysis activities by the project team consisting of the Geo-Heat Center, Geothermal Resources Council, Geothermal Education Office, Geothermal Energy Association, and the Washington State University Energy Program.

  9. The Occurrence of Pyrrhotite in the Ngawha Geothermal System, New Zealand

    SciTech Connect

    Cox, M.E.; Browne, P.R.L.

    1995-01-01

    The Ngawha geothermal system is low in all sulfide minerals, but in comparison to systems in the Taupo Volcanic Zone it contains more widely distributed pyrrhotite which is currently depositing, mainly in fractures. This reflects the high proportion of vapor in the Ngawha system. Pyrrhotite is most common in the upper part of the reservoir and lower part of the aquitard. The Ngawha pyrrhotite is of monoclinic and monoclinic + hexagonal structure.

  10. State Geological Survey Contributions to the National Geothermal Data System- Final Technical Report

    SciTech Connect

    Allison, M. Lee; Richard, Stephen M.

    2015-03-13

    The State Geological Survey Contributions to the National Geothermal Data System project is built on the work of the project managed by Boise State University to design and build the National Geothermal Data System, by deploying it nationwide and populating it with data principally from State Geological Surveys through collaboration with the Association of American State Geologists (AASG). This project subsequently incorporated the results of the design-build and other DOE-funded projects in support of the NGDS. The NGDS (www.geothermaldata.org) provides free open access to millions of data records, images, maps, and reports, sharing relevant geoscience, production, and land use data in 30+ categories to propel geothermal development and production in the U.S. NGDS currently serves information gathered from hundreds of the U.S. Department of Energy sponsored development and research projects and geologic data feeds from 60+ data providers throughout all 50 states. These data are relevant to geothermal energy exploration and development, but also have broad applicability in other areas including natural resources (e.g., energy, minerals, water), natural hazards, and land use and management.

  11. Development of Models to Simulate Tracer Tests for Characterization of Enhanced Geothermal Systems

    SciTech Connect

    Williams, Mark D.; Reimus, Paul; Vermeul, Vincent R.; Rose, Peter; Dean, Cynthia A.; Watson, Tom B.; Newell, D.; Leecaster, Kevin; Brauser, Eric

    2013-05-01

    A recent report found that power and heat produced from enhanced (or engineered) geothermal systems (EGSs) could have a major impact on the U.S energy production capability while having a minimal impact on the environment. EGS resources differ from high-grade hydrothermal resources in that they lack sufficient temperature distribution, permeability/porosity, fluid saturation, or recharge of reservoir fluids. Therefore, quantitative characterization of temperature distributions and the surface area available for heat transfer in EGS is necessary for the design and commercial development of the geothermal energy of a potential EGS site. The goal of this project is to provide integrated tracer and tracer interpretation tools to facilitate this characterization. This project was initially focused on tracer development with the application of perfluorinated tracer (PFT) compounds, non-reactive tracers used in numerous applications from atmospheric transport to underground leak detection, to geothermal systems, and evaluation of encapsulated PFTs that would release tracers at targeted reservoir temperatures. After the 2011 midyear review and subsequent discussions with the U.S. Department of Energy Geothermal Technology Program (GTP), emphasis was shifted to interpretive tool development, testing, and validation. Subsurface modeling capabilities are an important component of this project for both the design of suitable tracers and the interpretation of data from in situ tracer tests, be they single- or multi-well tests. The purpose of this report is to describe the results of the tracer and model development for simulating and conducting tracer tests for characterizing EGS parameters.

  12. Chlorine isotope geochemistry of Icelandic thermal fluids: Implications for geothermal system behavior at divergent plate boundaries

    NASA Astrophysics Data System (ADS)

    Stefánsson, Andri; Barnes, Jaime D.

    2016-09-01

    The chlorine isotope composition of thermal fluids from Iceland were measured in order to evaluate the source of chlorine and possible chlorine isotope fractionation in geothermal systems at divergent plate boundaries. The geothermal systems studied have a wide range of reservoir temperatures from 40 to 437 °C and in-situ pH of 6.15 to 7.15. Chlorine concentrations range from 5.2 to 171 ppm and δ37 Cl values are -0.3 to + 2.1 ‰ (n = 38). The δ37 Cl values of the thermal fluids are interpreted to reflect the source of the chlorine in the fluids. Geothermal processes such as secondary mineral formation, aqueous and vapor speciation and boiling were found to have minimal effects on the δ37 Cl values. However, further work is needed on incorporation of Cl into secondary minerals and its effect on Cl isotope fractionation. Results of isotope geochemical modeling demonstrate that the range of δ37 Cl values documented in the natural thermal fluids can be explained by leaching of the basaltic rocks by meteoric source water under geothermal conditions. Magmatic gas partitioning may also contribute to the source of Cl in some cases. The range of δ37 Cl values of the fluids result mainly from the large range of δ37 Cl values observed for Icelandic basalts, which range from -0.6 to + 1.2 ‰.

  13. Methodology of determining the uncertainty in the accessible geothermal resource base of identified hydrothermal convection systems

    USGS Publications Warehouse

    Nathenson, Manuel

    1978-01-01

    In order to quantify the uncertainty of estimates of the geothermal resource base in identified hydrothermal convection systems, a methodology is presented for combining estimates with uncertainties for temperature, area, and thickness of a geothermal reservoir into an estimate of the stored energy with uncertainty. Probability density functions for temperature, area, and thickness are assumed to be triangular in form. In order to calculate the probability distribution function for the stored energy in a single system or in many systems, a computer program for aggregating the input distribution functions using the Monte-Carlo method has been developed. To calculate the probability distribution of stored energy in a single system, an analytical expression is also obtained that is useful for calibrating the Monte Carlo approximation. For the probability distributions of stored energy in a single and in many systems, the central limit approximation is shown to give results ranging from good to poor.

  14. Geochemistry of sericite and chlorite in well 14-2 Roosevelt Hot Springs geothermal system and in mineralized hydrothermal systems

    SciTech Connect

    Ballantyne, J.M.

    1980-06-01

    Chemical compositions of chlorite and sericite from one production well in the Roosevelt geothermal system have been determined by electron probe methods and compared with compositions of chlorite and sericite from porphyry copper deposits. Modern system sericite and chlorite occur over a depth interval of 2 km and a temperature interval of 250/sup 0/C.

  15. Chemical geothermometers and mixing models for geothermal systems

    USGS Publications Warehouse

    Fournier, R.O.

    1977-01-01

    Qualitative chemical geothermometers utilize anomalous concentrations of various "indicator" elements in groundwaters, streams, soils, and soil gases to outline favorable places to explore for geothermal energy. Some of the qualitative methods, such as the delineation of mercury and helium anomalies in soil gases, do not require the presence of hot springs or fumaroles. However, these techniques may also outline fossil thermal areas that are now cold. Quantitative chemical geothermometers and mixing models can provide information about present probable minimum subsurface temperatures. Interpretation is easiest where several hot or warm springs are present in a given area. At this time the most widely used quantitative chemical geothermometers are silica, Na/K, and Na-K-Ca. ?? 1976.

  16. Structural investigations of Great Basin geothermal fields: Applications and implications

    SciTech Connect

    Faulds, James E; Hinz, Nicholas H.; Coolbaugh, Mark F

    2010-11-01

    Because fractures and faults are commonly the primary pathway for deeply circulating hydrothermal fluids, structural studies are critical to assessing geothermal systems and selecting drilling targets for geothermal wells. Important tools for structural analysis include detailed geologic mapping, kinematic analysis of faults, and estimations of stress orientations. Structural assessments are especially useful for evaluating geothermal fields in the Great Basin of the western USA, where regional extension and transtension combine with high heat flow to generate abundant geothermal activity in regions having little recent volcanic activity. The northwestern Great Basin is one of the most geothermally active areas in the USA. The prolific geothermal activity is probably due to enhanced dilation on N- to NNE-striking normal faults induced by a transfer of NW-directed dextral shear from the Walker Lane to NW-directed extension. Analysis of several geothermal fields suggests that most systems occupy discrete steps in normal fault zones or lie in belts of intersecting, overlapping, and/or terminating faults. Most fields are associated with steeply dipping faults and, in many cases, with Quaternary faults. The structural settings favoring geothermal activity are characterized by subvertical conduits of highly fractured rock along fault zones oriented approximately perpendicular to the WNW-trending least principal stress. Features indicative of these settings that may be helpful in guiding exploration for geothermal resources include major steps in normal faults, interbasinal highs, groups of relatively low discontinuous ridges, and lateral jogs or terminations of mountain ranges.

  17. The importance of methanotrophic activity in geothermal soils of Pantelleria island (Italy)

    NASA Astrophysics Data System (ADS)

    D'Alessandro, Walter; Gagliano, Antonina Lisa; Quatrini, Paola; Parello, Francesco

    2013-04-01

    Methane is a major contributor to the greenhouse effect, its atmospheric concentration being more than doubled since the XIX century. Every year 22 Tg of methane are released to the atmosphere from several natural and anthropogenic sources. Natural sources include geothermal/volcanic areas but the estimation of the total methane emission from these areas is currently not well defined since the balance between emission through degassing and microbial oxidation within the soils is not well known. Microbial oxidation in soils contributes globally for about 3-9% to the removal of methane from the atmosphere and recent studies evidenced methanotrophic activity also in soils of volcanic/geothermal areas despite their harsh environmental conditions (high temperatures, low pH and high concentrations of H2S and NH3). Methanotrophs are a diverse group of bacteria that are able to metabolize methane as their only source of carbon and energy and are found within the Alpha and Gamma classes of Proteobacteria and within the phylum Verrucomicrobia. Our purpose was to study the interaction between methanotrophic communities and the methane emitted from the geothermally most active site of Pantelleria island (Italy), Favara Grande, whose total methane emission has been previously estimated in about 2.5 t/a. Laboratory incubation experiments with soil samples from Favara Grande showed methane consumption values of up to 9500 ng g-1 dry soil per hour while soils collected outside the geothermal area consume less than 6 ng g-1 h-1. The maximum consumption was measured in the shallowest part of the soil profile (1-3 cm) and high values (>100 ng g-1 h-1) were maintained up to a depht of 15 cm. Furthermore, the highest consumption was measured at 37°C, and a still recognizable consumption (>20 ng g-1 h-1) at 80°C, with positive correlation with the methane concentration in the incubation atmosphere. These results can be considered a clear evidence of the presence of methanotrophs that

  18. Strategic optimization of large-scale vertical closed-loop shallow geothermal systems

    NASA Astrophysics Data System (ADS)

    Hecht-Méndez, J.; de Paly, M.; Beck, M.; Blum, P.; Bayer, P.

    2012-04-01

    Vertical closed-loop geothermal systems or ground source heat pump (GSHP) systems with multiple vertical borehole heat exchangers (BHEs) are attractive technologies that provide heating and cooling to large facilities such as hotels, schools, big office buildings or district heating systems. Currently, the worldwide number of installed systems shows a recurrent increase. By running arrays of multiple BHEs, the energy demand of a given facility is fulfilled by exchanging heat with the ground. Due to practical and technical reasons, square arrays of the BHEs are commonly used and the total energy extraction from the subsurface is accomplished by an equal operation of each BHE. Moreover, standard designing practices disregard the presence of groundwater flow. We present a simulation-optimization approach that is able to regulate the individual operation of multiple BHEs, depending on the given hydro-geothermal conditions. The developed approach optimizes the overall performance of the geothermal system while mitigating the environmental impact. As an example, a synthetic case with a geothermal system using 25 BHEs for supplying a seasonal heating energy demand is defined. The optimization approach is evaluated for finding optimal energy extractions for 15 scenarios with different specific constant groundwater flow velocities. Ground temperature development is simulated using the optimal energy extractions and contrasted against standard application. It is demonstrated that optimized systems always level the ground temperature distribution and generate smaller subsurface temperature changes than non-optimized ones. Mean underground temperature changes within the studied BHE field are between 13% and 24% smaller when the optimized system is used. By applying the optimized energy extraction patterns, the temperature of the heat carrier fluid in the BHE, which controls the overall performance of the system, can also be raised by more than 1 °C.

  19. Development of an Enhanced Two-Phase Production System at the Geysers Geothermal Field

    SciTech Connect

    Steven Enedy

    2001-12-14

    A method was developed to enhance geothermal steam production from two-phase wells at THE Geysers Geothermal Field. The beneficial result was increased geothermal production that was easily and economically delivered to the power plant.

  20. Strategies for Detecting Hidden Geothermal Systems by Near-Surface Gas Monitoring

    SciTech Connect

    Lewicki, Jennifer L.; Oldenburg, Curtis M.

    2004-12-15

    ''Hidden'' geothermal systems are those systems above which hydrothermal surface features (e.g., hot springs, fumaroles, elevated ground temperatures, hydrothermal alteration) are lacking. Emissions of moderate to low solubility gases (e.g., CO2, CH4, He) may be one of the primary near-surface signals from these systems. Detection of anomalous gas emissions related to hidden geothermal systems may therefore be an important tool to discover new geothermal resources. This study investigates the potential for CO2 detection and monitoring in the subsurface and above ground in the near-surface environment to serve as a tool to discover hidden geothermal systems. We focus the investigation on CO2 due to (1) its abundance in geothermal systems, (2) its moderate solubility in water, and (3) the wide range of technologies available to monitor CO2 in the near-surface environment. However, monitoring in the near-surface environment for CO2 derived from hidden geothermal reservoirs is complicated by the large variation in CO2 fluxes and concentrations arising from natural biological and hydrologic processes. In the near-surface environment, the flow and transport of CO2 at high concentrations will be controlled by its high density, low viscosity, and high solubility in water relative to air. Numerical simulations of CO2 migration show that CO2 concentrations can reach very high levels in the shallow subsurface even for relatively low geothermal source CO2 fluxes. However, once CO2 seeps out of the ground into the atmospheric surface layer, surface winds are effective at dispersing CO2 seepage. In natural ecological systems in the absence of geothermal gas emissions, near-surface CO2 fluxes and concentrations are primarily controlled by CO2 uptake by photosynthesis, production by root respiration, and microbial decomposition of soil/subsoil organic matter, groundwater degassing, and exchange with the atmosphere. Available technologies for monitoring CO2 in the near

  1. Geothermal handbook

    USGS Publications Warehouse

    1976-01-01

    presented which will allow the Service to provide input to the federal leasing process. As an impact information source by which to judge the appropriateness of a specific activity at a specific site, a discussion of activities-impacts is provided on a phase by phase basis. Mitigation and possible enhancement techniques are also presented so that the impacts of the development can be dealt with and the fish and wildlife situation improved. The Service can achieve its objective only if biological input is made throughout the entire process of geothermal development, from exploration to testing to full field operation. A discussion of geothermal leasing procedures emphasizes the timing and nature of Service participation in current interagency lease processing, and there is a provision for the utilization of new knowledge, techniques, and responses as experience is accumulated.

  2. Evaluation of noise associated with geothermal-development activities. Final report, July 31, 1979-April 30, 1982

    SciTech Connect

    Long, M.; Stern, R.

    1982-01-01

    This report was prepared for the purpose of ascertaining the current state of noise generation, suppression, and mitigation techniques associated with geothermal development. A description of the geothermal drilling process is included as well as an overview of geothermal development activities in the United States. Noise sources at the well site, along geothermal pipelines, and at the power plants are considered. All data presented are measured values by workers in the field and by Marshall Long/Acoustics. One particular well site was monitored for a period of 55 continuous days, and includes all sources of noise from the time that the drilling rig was brought in until the time that it was moved off site. A complete log of events associated with the drilling process is correlated with the noise measurements including production testing of the completed well. Data are also presented which compare measured values of geothermal noise with federal, state, county, and local standards. A section on control of geothermal noise is also given. Volume I of this document presents summary information.

  3. Advanced Horizontal Well Recirculation Systems for Geothermal Energy Recovery in Sedimentary Formations

    SciTech Connect

    Mike Bruno; Russell L. Detwiler; Kang Lao; Vahid Serajian; Jean Elkhoury; Julia Diessl; Nicky White

    2012-09-30

    There is increased recognition that geothermal energy resources are more widespread than previously thought, with potential for providing a significant amount of sustainable clean energy worldwide. Recent advances in drilling, completion, and production technology from the oil and gas industry can now be applied to unlock vast new geothermal resources, with some estimates for potential electricity generation from geothermal energy now on the order of 2 million megawatts. Terralog USA, in collaboration with the University of California, Irvine (UCI), are currently investigating advanced design concepts for paired horizontal well recirculation systems, optimally configured for geothermal energy recovery in permeable sedimentary and crystalline formations of varying structure and material properties. This two-year research project, funded by the US Department of Energy, includes combined efforts for: 1) Resource characterization; 2) Small and large scale laboratory investigations; 3) Numerical simulation at both the laboratory and field scale; and 4) Engineering feasibility studies and economic evaluations. The research project is currently in its early stages. This paper summarizes our technical approach and preliminary findings related to potential resources, small-scale laboratory simulation, and supporting numerical simulation efforts.

  4. Geophysical logging case history of the Raft River geothermal system, Idaho

    SciTech Connect

    Applegate, J.K.; Moens, T.A.

    1980-04-01

    Drilling to evaluate the geothermal resource in the Raft River Valley began in 1974 and resulted in the discovery of a geothermal reservoir at a depth of approximately 1523 m (500 ft). Several organizations and companies have been involved in the geophysical logging program. There is no comprehensive report on the geophysical logging, nor has there been a complete interpretation. The objectives of this study are to make an integrated interpretation of the available data and compile a case history. Emphasis has been on developing a simple interpretation scheme from a minimum of data sets. The Raft River geothermal system occurs in the Raft River Valley, which is a portion of the Basin and Range geomorphic province located in south central Idaho, south of the Snake River Plain. The valley is a late Cenozoic structural downwarp bounded by faults on the west, south, and east. The downwarp is filled with Tertiary and Paleozoic sediments, metasediments, and volcanics that overlie Precambrian rocks. The variety of rock types, the presence of alteration products, and the variability of fracturing make reliable interpretations difficult. However, the cross plotting of various parameters has allowed a determination of rock types and an analysis of the degree of alteration and the density of fractures. Thus, one can determine the relevant data necessary to assess a geothermal reservoir in similar rock types and use cross plots to potentially define the producing zones.

  5. Fracture Characterization in Enhanced Geothermal Systems by Wellbore and Reservoir Analysis

    SciTech Connect

    Horne, Roland N.; Li, Kewen; Alaskar, Mohammed; Ames, Morgan; Co, Carla; Juliusson, Egill; Magnusdottir, Lilja

    2012-06-30

    This report highlights the work that was done to characterize fractured geothermal reservoirs using production data. That includes methods that were developed to infer characteristic functions from production data and models that were designed to optimize reinjection scheduling into geothermal reservoirs, based on these characteristic functions. The characterization method provides a robust way of interpreting tracer and flow rate data from fractured reservoirs. The flow-rate data are used to infer the interwell connectivity, which describes how injected fluids are divided between producers in the reservoir. The tracer data are used to find the tracer kernel for each injector-producer connection. The tracer kernel describes the volume and dispersive properties of the interwell flow path. A combination of parametric and nonparametric regression methods were developed to estimate the tracer kernels for situations where data is collected at variable flow-rate or variable injected concentration conditions. The characteristic functions can be used to calibrate thermal transport models, which can in turn be used to predict the productivity of geothermal systems. This predictive model can be used to optimize injection scheduling in a geothermal reservoir, as is illustrated in this report.

  6. Exergy analysis of the performance of low-temperature district heating system with geothermal heat pump

    NASA Astrophysics Data System (ADS)

    Sekret, Robert; Nitkiewicz, Anna

    2014-03-01

    Exergy analysis of low temperature geothermal heat plant with compressor and absorption heat pump was carried out. In these two concepts heat pumps are using geothermal water at 19.5 oC with spontaneous outflow 24 m3/h as a heat source. The research compares exergy efficiency and exergy destruction of considered systems and its components as well. For the purpose of analysis, the heating system was divided into five components: geothermal heat exchanger, heat pump, heat distribution, heat exchanger and electricity production and transportation. For considered systems the primary exergy consumption from renewable and non-renewable sources was estimated. The analysis was carried out for heat network temperature at 50/40 oC, and the quality regulation was assumed. The results of exergy analysis of the system with electrical and absorption heat pump show that exergy destruction during the whole heating season is lower for the system with electrical heat pump. The exergy efficiencies of total system are 12.8% and 11.2% for the system with electrical heat pump and absorption heat pump, respectively.

  7. Potential for a significant deep basin geothermal system in Tintic Valley, Utah

    NASA Astrophysics Data System (ADS)

    Hardwick, C.; Kirby, S.

    2014-12-01

    The combination of regionally high heat flow, deep basins, and permeable reservoir rocks in the eastern Great Basin may yield substantial new geothermal resources. We explore a deep sedimentary basin geothermal prospect beneath Tintic Valley in central Utah using new 2D and 3D models coupled with existing estimates of heat flow, geothermometry, and shallow hydrologic data. Tintic Valley is a sediment-filled basin bounded to the east and west by bedrock mountain ranges where heat-flow values vary from 85 to over 240 mW/m2. Based on modeling of new and existing gravity data, a prominent 30 mGal low indicates basin fill thickness may exceed 2 km. The insulating effect of relatively low thermal conductivity basin fill in Tintic Valley, combined with typical Great Basin heat flow, predict temperatures greater than 150 °C at 3 km depth. The potential reservoir beneath the basin fill is comprised of Paleozoic carbonate and clastic rocks. The hydrology of the Tintic Valley is characterized by a shallow, cool groundwater system that recharges along the upper reaches of the basin and discharges along the valley axis and to a series of wells. The east mountain block is warm and dry, with groundwater levels just above the basin floor and temperatures >50 °C at depth. The west mountain block contains a shallow, cool meteoric groundwater system. Fluid temperatures over 50 °C are sufficient for direct-use applications, such as greenhouses and aquaculture, while temperatures exceeding 140°C are suitable for binary geothermal power plants. The geologic setting and regionally high heat flow in Tintic Valley suggest a geothermal resource capable of supporting direct-use geothermal applications and binary power production could be present.

  8. Copahue Geothermal System: A Volcanic Environment with Rich Extreme Prokaryotic Biodiversity

    PubMed Central

    Urbieta, María Sofía; Willis Porati, Graciana; Segretín, Ana Belén; González-Toril, Elena; Giaveno, María Alejandra; Donati, Edgardo Rubén

    2015-01-01

    The Copahue geothermal system is a natural extreme environment located at the northern end of the Cordillera de los Andes in Neuquén province in Argentina. The geochemistry and consequently the biodiversity of the area are dominated by the activity of the Copahue volcano. The main characteristic of Copahue is the extreme acidity of its aquatic environments; ponds and hot springs of moderate and high temperature as well as Río Agrio. In spite of being an apparently hostile location, the prokaryotic biodiversity detected by molecular ecology techniques as well as cultivation shows a rich and diverse environment dominated by acidophilic, sulphur oxidising bacteria or archaea, depending on the conditions of the particular niche studied. In microbial biofilms, found in the borders of the ponds where thermal activity is less intense, the species found are completely different, with a high presence of cyanobacteria and other photosynthetic species. Our results, collected during more than 10 years of work in Copahue, have enabled us to outline geomicrobiological models for the different environments found in the ponds and Río Agrio. Besides, Copahue seems to be the habitat of novel, not yet characterised autochthonous species, especially in the domain Archaea.

  9. Copahue Geothermal System: A Volcanic Environment with Rich Extreme Prokaryotic Biodiversity

    PubMed Central

    Urbieta, María Sofía; Willis Porati, Graciana; Segretín, Ana Belén; González-Toril, Elena; Giaveno, María Alejandra; Donati, Edgardo Rubén

    2015-01-01

    The Copahue geothermal system is a natural extreme environment located at the northern end of the Cordillera de los Andes in Neuquén province in Argentina. The geochemistry and consequently the biodiversity of the area are dominated by the activity of the Copahue volcano. The main characteristic of Copahue is the extreme acidity of its aquatic environments; ponds and hot springs of moderate and high temperature as well as Río Agrio. In spite of being an apparently hostile location, the prokaryotic biodiversity detected by molecular ecology techniques as well as cultivation shows a rich and diverse environment dominated by acidophilic, sulphur oxidising bacteria or archaea, depending on the conditions of the particular niche studied. In microbial biofilms, found in the borders of the ponds where thermal activity is less intense, the species found are completely different, with a high presence of cyanobacteria and other photosynthetic species. Our results, collected during more than 10 years of work in Copahue, have enabled us to outline geomicrobiological models for the different environments found in the ponds and Río Agrio. Besides, Copahue seems to be the habitat of novel, not yet characterised autochthonous species, especially in the domain Archaea. PMID:27682093

  10. Copahue Geothermal System: A Volcanic Environment with Rich Extreme Prokaryotic Biodiversity.

    PubMed

    Urbieta, María Sofía; Porati, Graciana Willis; Segretín, Ana Belén; González-Toril, Elena; Giaveno, María Alejandra; Donati, Edgardo Rubén

    2015-07-08

    The Copahue geothermal system is a natural extreme environment located at the northern end of the Cordillera de los Andes in Neuquén province in Argentina. The geochemistry and consequently the biodiversity of the area are dominated by the activity of the Copahue volcano. The main characteristic of Copahue is the extreme acidity of its aquatic environments; ponds and hot springs of moderate and high temperature as well as Río Agrio. In spite of being an apparently hostile location, the prokaryotic biodiversity detected by molecular ecology techniques as well as cultivation shows a rich and diverse environment dominated by acidophilic, sulphur oxidising bacteria or archaea, depending on the conditions of the particular niche studied. In microbial biofilms, found in the borders of the ponds where thermal activity is less intense, the species found are completely different, with a high presence of cyanobacteria and other photosynthetic species. Our results, collected during more than 10 years of work in Copahue, have enabled us to outline geomicrobiological models for the different environments found in the ponds and Río Agrio. Besides, Copahue seems to be the habitat of novel, not yet characterised autochthonous species, especially in the domain Archaea.

  11. Modeling of thermodynamic and chemical changes in low-temperature geothermal systems

    SciTech Connect

    Spencer, A.L.

    1986-12-01

    A method was developed to incorporate the transport of several chemical components into a model of the transport of fluid mass and heat within a geothermal system. It was demonstrated that the use of coupled hydrological, thermal and chemical data allows for the determination of field porosities, amounts and regions of cool recharge into the system as well as field permeabilities and the hot reservoir volume. With the additional information a reliable prediction of the long-term cooling rate can be made.

  12. Fluid-rock interactions in CO2-saturated, granite-hosted geothermal systems: Implications for natural and engineered systems from geochemical experiments and models

    NASA Astrophysics Data System (ADS)

    Lo Ré, Caroline; Kaszuba, John P.; Moore, Joseph N.; McPherson, Brian J.

    2014-09-01

    Hydrothermal experiments were conducted and geochemical models constructed to evaluate the geochemical and mineralogical response of fractured granite and granite + epidote in contact with thermal water, with and without supercritical CO2, at 250 °C and 25-45 MPa. Illite ± smectite ± zeolite(?) precipitate as secondary minerals at the expense of K-feldspar, oligoclase, and epidote. Illite precipitates in experiments reacting granite and granite + epidote with water; metastable smectite forms in the experiments injected with supercritical CO2. Waters are supersaturated with respect to quartz and saturated with respect to chalcedony in CO2-charged experiments, but neither mineral formed. Carbonate formation is predicted for experiments injected with supercritical CO2, but carbonate only formed during cooling and degassing of the granite + epidote + CO2 experiment. Experimental results provide insight into the buffering capacity of granites as well as the drivers of clay formation. Metastable smectite in the experiments is attributed to high water-rock ratios, high silica activities, and high CO2 and magnesium-iron concentrations. Smectite precipitation in supercritical CO2-bearing geothermal systems may affect reservoir permeability. Silicate formation may create or thicken caps within or on the edges of geothermal reservoirs. Carbonate formation, as desired for carbon sequestration projects coinciding with geothermal systems, may require extended periods of time; cooling and degassing of CO2-saturated waters leads to carbonate precipitation, potentially plugging near-surface production pathways.

  13. Energy Returned On Investment of Engineered Geothermal Systems Annual Report FY2011

    SciTech Connect

    Mansure, A.J.

    2011-12-31

    Energy Return On Investment (EROI) is an important figure of merit for assessing the viability of energy alternatives. For geothermal electric power generation, EROI is determined by the electricity delivered to the consumer compared to the energy consumed to construct, operate, and decommission the facility. Critical factors in determining the EROI of Engineered Geothermal Systems (EGS) are examined in this work. These include the input energy embodied into the system. The embodied energy includes the energy contained in the materials, as well as, that consumed in each stage of manufacturing from mining the raw materials to assembling the finished plant. Also critical are the system boundaries and value of the energy - heat is not as valuable as electrical energy.

  14. Application of Fusion Gyrotrons to Enhanced Geothermal Systems (EGS)

    NASA Astrophysics Data System (ADS)

    Woskov, P.; Einstein, H.; Oglesby, K.

    2013-10-01

    The potential size of geothermal energy resources is second only to fusion energy. Advances are needed in drilling technology and heat reservoir formation to realize this potential. Millimeter-wave (MMW) gyrotrons and related technologies developed for fusion energy research could contribute to enabling EGS. Directed MMW energy can be used to advance rock penetration capabilities, borehole casing, and fracking. MMWs are ideally suited because they can penetrate through small particulate extraction plumes, can be efficiently guided long distances in borehole dimensions, and continuous megawatt sources are commercially available. Laboratory experiments with a 10 kW, 28 GHz CPI gyrotron have shown that granite rock can be fractured and melted with power intensities of about 1 kW/cm2 and minute exposure times. Observed melted rock MMW emissivity and estimated thermodynamics suggest that penetrating hot, hard crystalline rock formations may be economic with fusion research developed MMW sources. Supported by USDOE, Office of Energy Efficiency and Renewable Energy and Impact Technologies, LLC.

  15. Joint Geophysical Characterization of Geothermal System in Menengai, Kenya Using Magnetotelluric and Gravity

    NASA Astrophysics Data System (ADS)

    Wamalwa, A. M.; Serpa, L. F.

    2010-12-01

    Geothermal exploration typically focuses on the identification of the heat source and defining the plumbing system that allows fluid flow at depths of 1-5 km where production of geothermal energy is feasible. The faults and fracture systems that make up the plumbing systems for hydrothermal fluids are often offset from their source and may be entirely hidden beneath basin fill or volcanic flows. Thus, a variety of different geophysical methods are used to detect the fracture zones and heat sources, including electrical, electromagnetic, seismic, and potential field techniques, each not giving a unique interpretation. Therefore a careful qualitative and quantitative joint analysis of these data based on common/shared geology may improve the overall understanding of the study area. To determine the extent of geothermal system as the target for development around Menengai volcano in the southern region of the Kenya rift valley, Magnetotelluric (MT) and gravity data were analysed. Subsurface conductivity and density distribution were used to infer the possible geological structures that relate to permeability and the heat source. Density gradient in the NW and NE north of the Menengai caldera defines the rift faults. A low resistivity layer at about 500 m and 1 km is interpreted as alteration clay minerals and overlays a relatively resistive zone. A low resistivity region at a depth of about 5-6 km is inferred to be a cooling magmatic body.

  16. Enhanced Geothermal Systems Project Development Solicitation - Final Report - 09/30/2000 - 02/01/2001

    SciTech Connect

    Nielson, Dennis L.

    2001-05-07

    The Enhanced Geothermal System concept is to develop the technology required to extract energy from the reduced permeability zones that underlie all high-temperature geothermal systems. Our concept is that injection wells will be drilled into the high temperature zone. The wells will identify fractures that are only poorly connected to the overlying reservoir. Water injected into these fractures will cause them to propagate through thermal contraction, increase in hydrostatic pressure, and reduction of effective stress. The fractures will connect with the overlying normal temperature reservoir, and steam will be produced from existing production wells. The injection water will generate high thermal quality steam while mitigating problems relating to high gas and chloride.

  17. Hydrogeochemistry of the Qualibou Caldera Geothermal System, St. Lucia, West Indies

    SciTech Connect

    Goff, F.; Vuataz, F.D.

    1984-01-01

    Interpretation of hydrogeochemical data and supporting geologic and electric resistivity data have been used to define the basic structure of the Qualibou Caldera geothermal system and propose a model of hydrologic flow. The geothermal system at Sulphur Springs consists of three layers: (1) an upper steam condensate zone; (2) an intermediate vapor zone, which may be restricted to the Sulphur Springs area only; and (3) a lower brine zone. Four lines of evidence suggest that temperatures of the brine layer may exceed 230/sup 0/C at depths of perhaps 1 km. Outlying thermal springs along the northwest side of the caldera do not indicate derivation from underlying high-temperature sources. It is suggested that the main reservoir upflows in the Belfond-Sulphur Springs area and flows laterally in the subsurface toward the northwest caldera wall.

  18. Interaction of cold-water aquifers with exploited reservoirs of the Cerro Prieto geothermal system

    USGS Publications Warehouse

    Truesdell, Alfred; Lippmann, Marcelo

    1990-01-01

    Cerro Prieto geothermal reservoirs tend to exhibit good hydraulic communication with adjacent cool groundwater aquifers. Under natural state conditions the hot fluids mix with the surrounding colder waters along the margins of the geothermal system, or discharge to shallow levels by flowing up fault L. In response to exploitation reservoir pressures decrease, leading to changes in the fluid flow pattern in the system and to groundwater influx. The various Cerro Prieto reservoirs have responded differently to production, showing localized near-well or generalized boiling, depending on their access to cool-water recharge. Significant cooling by dilution with groundwater has only been observed in wells located near the edges of the field. In general, entry of cool water at Cerro Prieto is beneficial because it tends to maintain reservoir pressures, restrict boiling, and lengthen the life and productivity of wells.

  19. Applications of fractured continuum model to enhanced geothermal system heat extraction problems.

    PubMed

    Kalinina, Elena A; Klise, Katherine A; McKenna, Sean A; Hadgu, Teklu; Lowry, Thomas S

    2014-01-01

    This paper describes the applications of the fractured continuum model to the different enhanced geothermal systems reservoir conditions. The capability of the fractured continuum model to generate fracture characteristics expected in enhanced geothermal systems reservoir environments are demonstrated for single and multiple sets of fractures. Fracture characteristics are defined by fracture strike, dip, spacing, and aperture. The paper demonstrates how the fractured continuum model can be extended to represent continuous fractured features, such as long fractures, and the conditions in which the fracture density varies within the different depth intervals. Simulations of heat transport using different fracture settings were compared with regard to their heat extraction effectiveness. The best heat extraction was obtained in the case when fractures were horizontal. A conventional heat extraction scheme with vertical wells was compared to an alternative scheme with horizontal wells. The heat extraction with the horizontal wells was significantly better than with the vertical wells when the injector was at the bottom.

  20. Underground Mine Water Heating and Cooling Using Geothermal Heat Pump Systems

    SciTech Connect

    Watzlaf, G.R.; Ackman, T.E.

    2006-03-01

    In many regions of the world, flooded mines are a potentially cost-effective option for heating and cooling using geothermal heat pump systems. For example, a single coal seam in Pennsylvania, West Virginia, and Ohio contains 5.1 x 1012 L of water. The growing volume of water discharging from this one coal seam totals 380,000 L/min, which could theoretically heat and cool 20,000 homes. Using the water stored in the mines would conservatively extend this option to an order of magnitude more sites. Based on current energy prices, geothermal heat pump systems using mine water could reduce annual costs for heating by 67% and cooling by 50% over conventional methods (natural gas or heating oil and standard air conditioning).

  1. U-Th dating of vein calcite by LA-MC-ICP-MS: preliminary results from geothermal systems

    NASA Astrophysics Data System (ADS)

    McGee, L. E.; Reich, M.; Rodriguez, V.; Leisen, M.; Barra, F.

    2014-12-01

    The measurement of U-series isotopes in precipitated minerals such as calcite holds various challenges, including low U and Th concentrations (in the ppb-ppt range), and the presence of detrital 232Th which can lead to age overestimations. Additionally, as yet there does not exist a calcite standard reference material for inter-laboratory accuracy and precision comparison, with most laboratories using their own in-house standard material and focussing largely on application to paleoclimate studies (e.g. corals and speleothems). In actively deforming regions, high-pressure hydrothermal fluids play an important role in faulting and vein formation, and commonly fault rupture is followed by rapid sealing through mineral precipitation. Therefore, precise dating of vein growth is of special importance to our understanding of the complex interplay between seismic events and fluid flow in the upper crust, and opens up a new field of study using U-Th techniques. The ability to accurately date fault-filling calcite within such settings has the power to elucidate the connection between structure and fluid flow in the development of geothermal systems, and provide valuable information on the longevity of the heat/water source, in addition to regional magmatic history. We are developing U-Th measurements and ages of vein calcite from geothermal systems using a Neptune Plus MC-ICP-MS (with 5 CDDs and 3 SEMs) coupled to an excimer 193nm Photon Machines laser. We will be comparing our results with an 189ka in-house flowstone calcite standard previously dated by TIMS, as well as developing a geothermal calcite standard.

  2. Geothermal systems of the Mono Basin-Long Valley region, eastern California and western Nevada

    SciTech Connect

    Higgins, C.T.; Flynn, T.; Chapman, R.H.; Trexler, D.T.; Chase, G.R.; Bacon, C.F.; Ghusn, G. Jr.

    1985-01-01

    The region that includes Mono Basin, Long Valley, the Bridgeport-Bodie Hills area, and Aurora, in eastern California and western Nevada was studied to determine the possible causes and interactions of the geothermal anomalies in the Mono Basin-Long Valley region as a whole. A special goal of the study was to locate possible shallow bodies of magma and to determine their influence on the hydrothermal systems in the region. (ACR)

  3. Value analysis of advanced heat rejection systems for geothermal power plants

    SciTech Connect

    Bliem, C.; Zangrando, F.; Hassani, V.

    1996-12-31

    A computer model and a methodology has been developed to perform value analysis for small, low-temperature binary geothermal power plants. The value analysis method allows for incremental changes in the levelized energy cost (LEC) to be determined between a baseline plant and a modified plant. Thermodynamic cycle analyses and component sizing are carried out in the model followed by economic analysis which provides LEC results. The emphasis of the present work has been on evaluating different types of heat rejection systems.

  4. The Domuyo volcanic system: An enormous geothermal resource in Argentine Patagonia

    NASA Astrophysics Data System (ADS)

    Chiodini, Giovanni; Liccioli, Caterina; Vaselli, Orlando; Calabrese, Sergio; Tassi, Franco; Caliro, Stefano; Caselli, Alberto; Agusto, Mariano; D'Alessandro, Walter

    2014-03-01

    A geochemical survey of the main thermal waters discharging in the southwestern part of the Domuyo volcanic complex (Argentina), where the latest volcanic activity dates to 0.11 Ma, has highlighted the extraordinarily high heat loss from this remote site in Patagonia. The thermal water discharges are mostly Na-Cl in composition and have TDS values up to 3.78 g L- 1 (El Humazo). A simple hydrogeochemical approach shows that 1,100 to 1,300 kg s- 1 of boiling waters, which have been affected by shallow steam separation, flow into the main drainage of the area (Rio Varvarco). A dramatic increase of the most conservative species such as Na, Cl and Li from the Rio Varvarco from upstream to downstream was observed and related solely to the contribution of hydrothermal fluids. The equilibrium temperatures of the discharging thermal fluids, calculated on the basis of the Na-K-Mg geothermometer, are between 190 °C and 230 °C. If we refer to a liquid originally at 220 °C (enthalpy = 944 J g- 1), the thermal energy release can be estimated as high as 1.1 ± 0.2 GW, a value that is much higher than the natural release of heat in other important geothermal fields worldwide, e.g., Mutnovsky (Russia), Wairakei (New Zealand) and Lassen Peak (USA). This value is the second highest measured advective heat flux from any hydrothermal system on Earth after Yellowstone.

  5. Geothermal Energy.

    ERIC Educational Resources Information Center

    Eaton, William W.

    Described are the origin and nature of geothermal energy. Included is the history of its development as an energy source, technological considerations affecting its development as an energy source, its environmental effects, economic considerations, and future prospects of development in this field. Basic system diagrams of the operation of a…

  6. Assessment of the Geothermal System Near Stanley, Idaho

    SciTech Connect

    Trent Armstrong; John Welhan; Mike McCurry

    2012-06-01

    The City of Stanley, Idaho (population 63) is situated in the Salmon River valley of the central Idaho highlands. Due to its location and elevation (6270 feet amsl) it is one of the coldest locales in the continental U.S., on average experiencing frost 290 days of the year as well as 60 days of below zero (oF) temperatures. Because of high snowfall (76 inches on average) and the fact that it is at the terminus of its rural grid, the city also frequently endures extended power outages during the winter. To evaluate its options for reducing heating costs and possible local power generation, the city obtained a rural development grant from the USDA and commissioned a feasibility study through author Roy Mink to determine whether a comprehensive site characterization and/or test drilling program was warranted. Geoscience students and faculty at Idaho State University (ISU), together with scientists from the Idaho Geological Survey (IGS) and Idaho National Laboratory (INL) conducted three field data collection campaigns between June, 2011 and November, 2012 with the assistance of author Beckwith who arranged for food, lodging and local property access throughout the field campaigns. Some of the information collected by ISU and the IGS were compiled by author Mink and Boise State University in a series of progress reports (Makovsky et al., 2011a, b, c, d). This communication summarizes all of the data collected by ISU including data that were compiled as part of the IGS’s effort for the National Geothermal Data System’s (NGDS) data compilation project funded by the Department of Energy and coordinated by the Arizona Geological Survey.

  7. Simulation of water-rock interaction in the yellowstone geothermal system using TOUGHREACT

    SciTech Connect

    Dobson, P.F.; Salah, S.; Spycher, N.; Sonnenthal, E.

    2003-04-28

    The Yellowstone geothermal system provides an ideal opportunity to test the ability of reactive transport models to accurately simulate water-rock interaction. Previous studies of the Yellowstone geothermal system have characterized water-rock interaction through analysis of rocks and fluids obtained from both surface and downhole samples. Fluid chemistry, rock mineralogy, permeability, porosity, and thermal data obtained from the Y-8 borehole in Upper Geyser Basin were used to constrain a series of reactive transport simulations of the Yellowstone geothermal system using TOUGHREACT. Three distinct stratigraphic units were encountered in the 153.4 m deep Y-8 drill core: volcaniclastic sandstone, perlitic rhyolitic lava, and nonwelded pumiceous tuff. The main alteration phases identified in the Y-8 core samples include clay minerals, zeolites, silica polymorphs, adularia, and calcite. Temperatures observed in the Y-8 borehole increase with depth from sub-boiling conditions at the surface to a maximum of 169.8 C at a depth of 104.1 m, with near-isothermal conditions persisting down to the well bottom. 1-D models of the Y-8 core hole were constructed to determine if TOUGHREACT could accurately predict the observed alteration mineral assemblage given the initial rock mineralogy and observed fluid chemistry and temperatures. Preliminary simulations involving the perlitic rhyolitic lava unit are consistent with the observed alteration of rhyolitic glass to form celadonite.

  8. Simulation of water-rock interaction in the Yellowstone geothermal system using TOUGHREACT

    SciTech Connect

    Dobson, Patrick F.; Salah, Sonia; Spycher, Nicolas; Sonnenthal, Eric L.

    2003-04-28

    The Yellowstone geothermal system provides an ideal opportunity to test the ability of reactive transport models to simulate the chemical and hydrological effects of water-rock interaction. Previous studies of the Yellowstone geothermal system have characterized water-rock interaction through analysis of rocks and fluids obtained from both surface and downhole samples. Fluid chemistry, rock mineralogy, permeability, porosity, and thermal data obtained from the Y-8 borehole in Upper Geyser Basin were used to constrain a series of reactive transport simulations of the Yellowstone geothermal system using TOUGHREACT. Three distinct stratigraphic units were encountered in the 153.4 m deep Y-8 drill core: volcaniclastic sandstone, perlitic rhyolitic lava, and nonwelded pumiceous tuff. The main alteration phases identified in the Y-8 core samples include clay minerals, zeolites, silica polymorphs, adularia, and calcite. Temperatures observed in the Y-8 borehole increase with depth from sub-boiling conditions at the surface to a maximum of 169.8 C at a depth of 104.1 m, with near-isothermal conditions persisting down to the well bottom. 1-D models of the Y-8 core hole were constructed to simulate the observed alteration mineral assemblage given the initial rock mineralogy and observed fluid chemistry and temperatures. Preliminary simulations involving the perlitic rhyolitic lava unit are consistent with the observed alteration of rhyolitic glass to form celadonite.

  9. Ground heat flux and power sources of low-enthalpy geothermal systems

    NASA Astrophysics Data System (ADS)

    Bayer, Peter; Blum, Philipp; Rivera, Jaime A.

    2015-04-01

    Geothermal heat pumps commonly extract energy from the shallow ground at depths as low as approximately 400 m. Vertical borehole heat exchangers are often applied, which are seasonally operated for decades. During this lifetime, thermal anomalies are induced in the ground and surface-near aquifers, which often grow over the years and which alleviate the overall performance of the geothermal system. As basis for prediction and control of the evolving energy imbalance in the ground, focus is typically set on the ground temperatures. This is reflected in regulative temperature thresholds, and in temperature trends, which serve as indicators for renewability and sustainability. In our work, we examine the fundamental heat flux and power sources, as well as their temporal and spatial variability during geothermal heat pump operation. The underlying rationale is that for control of ground temperature evolution, knowledge of the primary heat sources is fundamental. This insight is also important to judge the validity of simplified modelling frameworks. For instance, we reveal that vertical heat flux from the surface dominates the basal heat flux towards a borehole. Both fluxes need to be accounted for as proper vertical boundary conditions in the model. Additionally, the role of horizontal groundwater advection is inspected. Moreover, by adopting the ground energy deficit and long-term replenishment as criteria for system sustainability, an uncommon perspective is adopted that is based on the primary parameter rather than induced local temperatures. In our synthetic study and dimensionless analysis, we demonstrate that time of ground energy recovery after system shutdown may be longer than what is expected from local temperature trends. In contrast, unrealistically long recovery periods and extreme thermal anomalies are predicted without account for vertical ground heat fluxes and only when the energy content of the geothermal reservoir is considered.

  10. Thermo-poroelastic numerical modelling for enhanced geothermal system performance: Case study of the Groß Schönebeck reservoir

    NASA Astrophysics Data System (ADS)

    Jacquey, Antoine B.; Cacace, Mauro; Blöcher, Guido; Watanabe, Norihiro; Huenges, Ernst; Scheck-Wenderoth, Magdalena

    2016-08-01

    Significant pressure and temperature changes can occur within geothermal reservoirs caused by injection and production of fluid which can affect transport properties of the rocks and therefore alter reservoir performance and sustainability. To understand the coupling between transport properties evolution and state variable changes, a complete description of the mechanical behavior of the reservoir is required which should consider thermo- and poroelastic effects. This study aims to integrate transport properties evolution for coupled thermo-hydro-mechanical (THM) process modelling of fluid-bearing reservoirs. This approach is here applied to the geothermal research site of Groß Schönebeck (40 km north of Berlin, Germany) which consists of a doublet system at a target depth of about - 4100 m in which both injection and production wells have been hydraulically stimulated. A 3D reservoir model including the main geological units, major natural fault zones and hydraulic fractures is integrated in the finite-element method-based simulator OpenGeoSys for modelling coupled THM processes during geothermal activity. One challenge of this study is to integrate both hydro-geological and physical complexity to better describe the dynamic behavior of the geothermal reservoir. From the results of the simulation, thermal breakthrough is observed after 18 years of injection and life time of the system has been evaluated as 50 years. Furthermore, a 5.5% increase of porosity around the injection well is observed as well as an increase of the anisotropy ratio for permeability (kz/kxy) of about 2%. These transport properties enhancements lead to a decrease of the thermal breakthrough time (around - 8%) and life time of the system (- 14%) compared to classic thermo-hydro simulations with constant transport properties. The results presented here provide therefore valuable insights for understanding porosity and permeability distributions and evolutions during injection and production

  11. Quantifying the undiscovered geothermal resources of the United States

    USGS Publications Warehouse

    Williams, Colin F.; Reed, Marshall J.; DeAngelo, Jacob; Galanis, S. Peter

    2009-01-01

    In 2008, the U.S. Geological Survey (USGS) released summary results of an assessment of the electric power production potential from the moderate- and high-temperature geothermal resources of the United States (Williams et al., 2008a; USGS Fact Sheet 2008-3082; http://pubs.usgs.gov/fs/2008/3082). In the assessment, the estimated mean power production potential from undiscovered geothermal resources is 30,033 Megawatts-electric (MWe), more than three times the estimated mean potential from identified geothermal systems: 9057 MWe. The presence of significant undiscovered geothermal resources has major implications for future exploration and development activities by both the government and private industry. Previous reports summarize the results of techniques applied by the USGS and others to map the spatial distribution of undiscovered resources. This paper describes the approach applied in developing estimates of the magnitude of the undiscovered geothermal resource, as well as the manner in which that resource is likely to be distributed among geothermal systems of varying volume and temperature. A number of key issues constrain the overall estimate. One is the degree to which characteristics of the undiscovered resources correspond to those observed among identified geothermal systems. Another is the evaluation of exploration history, including both the spatial distribution of geothermal exploration activities relative to the postulated spatial distribution of undiscovered resources and the probability of successful discoveries from the application of standard geothermal exploration techniques. Also significant are the physical, chemical, and geological constraints on the formation and longevity of geothermal systems. Important observations from this study include the following. (1) Some of the largest identified geothermal systems, such as The Geysers vapor-dominated system in northern California and the diverse geothermal manifestations found in Yellowstone

  12. Energy balance and economic feasibility of shallow geothermal systems for winery industry

    NASA Astrophysics Data System (ADS)

    Ruiz-Mazarrón, F.; Almoguera-Millán, J.; García-Llaneza, J.; Perdigones, A.

    2012-04-01

    The search of energy efficient solutions has not yet been accomplished in agro-food constructions, for which technical studies and orientations are needed to find energy efficient solutions adapted to the environment. The main objective of this investigation is to evaluate the effectiveness of using shallow geothermal energy for the winery industry. World wine production in 2009 stood at 27100 millions of litres [1]. World spends 320 billion Euros on wine a year, according to industry insiders. On average, it is estimated that producing 1 litre of wine sold in a 75 cl glass bottle costs around 0.5-1.2 Euros /litre [2]. The process of ageing the wine could substantially increase production costs. Considering the time required for the aging of wine (months or years) and the size of the constructions, the use of an air conditioning system implies a considerable increase in energy consumption. Underground wine cellars have been in use for centuries for making and ageing wine. Ground thermal inertia provides protection from outdoor temperature oscillation and maintains thermal stability without energy consumption [3]. Since the last century, production of wine has moved to buildings above ground that have several advantages: lower construction cost, more space, etc. Nevertheless, these constructions require a large energy consumption to maintain suitable conditions for the ageing and conservation of wine. This change of construction techniques is the cause of an increase in energy consumption in modern wineries. The use of shallow geothermal energy can be a good alternative to take advantage of the benefits of aboveground buildings and underground constructions simultaneously. Shallow geothermal systems can meet the needs of heating and cooling using a single installation, maintaining low energy consumption. Therefore, it could be a good alternative to conventional HVAC systems. The main disadvantage of geothermal systems is the high cost of investment required. This

  13. TOUGH2 grid generator for simulations of geothermal heat pump systems

    NASA Astrophysics Data System (ADS)

    Kim, Seong-Kyun; Bae, Gwang-Ok; Lee, Kang-Kun

    2015-04-01

    We present a method to generate an unstructured Voronoi grid for its use in TOUGH2 simulations of geothermal heat pump systems. A series of codes is developed to create Voronoi cell center points that are placed at specific positions for well- or pipe-shaped Voronoi grids, to generate a three-dimensional grid and TOUGH2 input files from generated Voronoi cell vertices, and to visualize the generated grid and simulation results by ParaView. AMESH program is used to calculate the x- and y-coordinates of the Voronoi cell vertices from the Voronoi cell center points. We show the desired form of grid from the developed series of codes and test with confidence the presented method through simulations of water production/injection from/to the various kinds of the geothermal wells.

  14. Multielement geochemistry of solid materials in geothermal systems and its applications. Part 1. Hot-water system at the Roosevelt Hot Springs KGRA, Utah

    SciTech Connect

    Bamford, R.W.; Christensen, O.D.; Capuano, R.M.

    1980-02-01

    Geochemical studies of the geothermal system at Roosevelt Hot Springs, Utah, have led to development of chemical criteria for recognition of major features of the system and to a three-dimensional model for chemical zoning in the system. Based on this improved level of understanding several new or modified geochemical exploration and assessment techniques have been defined and are probably broadly applicable to evaluation of hot-water geothermal systems. The main purpose of this work was the development or adaptation of solids geochemical exploration techniques for use in the geothermal environment. (MHR)

  15. Insights From Laboratory Experiments On Simulated Faults With Application To Fracture Evolution In Geothermal Systems

    SciTech Connect

    Stephen L. Karner, Ph.D

    2006-06-01

    Laboratory experiments provide a wealth of information related to mechanics of fracture initiation, fracture propagation processes, factors influencing fault strength, and spatio-temporal evolution of fracture properties. Much of the existing literature reports on laboratory studies involving a coupling of thermal, hydraulic, mechanical, and/or chemical processes. As these processes operate within subsurface environments exploited for their energy resource, laboratory results provide insights into factors influencing the mechanical and hydraulic properties of geothermal systems. I report on laboratory observations of strength and fluid transport properties during deformation of simulated faults. The results show systematic trends that vary with stress state, deformation rate, thermal conditions, fluid content, and rock composition. When related to geophysical and geologic measurements obtained from engineered geothermal systems (e.g. microseismicity, wellbore studies, tracer analysis), laboratory results provide a means by which the evolving thermal reservoir can be interpreted in terms of physico-chemical processes. For example, estimates of energy release and microearthquake locations from seismic moment tensor analysis can be related to strength variations observed from friction experiments. Such correlations between laboratory and field data allow for better interpretations about the evolving mechanical and fluid transport properties in the geothermal reservoir – ultimately leading to improvements in managing the resource.

  16. Thermal regime of the Escalante Desert, Utah, with an analysis of the the Newcastle Geothermal System

    SciTech Connect

    Chapman, D.S.; Clement, M.D.; Mase, C.W.

    1981-12-10

    Twenty-five new heat flow measurements are presented for the Escalante Desert region within the Great Basin of the wester United States. Heat flow, excluding geothermal areas, ranges from 43 to 350 mW m/sup -2/, but much of the variability may be caused by deeply circulating groundwater redistributing the regional flux. A subset of 10 sites drilled specifically to characterize the heat flow of the region yielded a mean of 100 mW m/sup -2/ with a standard deviation of 22 mW m/sup -2/. A comparison of thermal conductivities of solid cylindrical discs and rock chips (rhyolite to andesite tuffs) confirmed the importance of porosity corrections to thermal conductivity measurements. A 'blind' geothermal system southwest of Newastle, Utah, situated within the Escalante Desert, has also been studied. Temperature Desert, has also been studied. Temperatures of 110/sup 0/C are observed only 75 m below the ground surface. Heat flow results from 11 drillholes in this region yield values between 163 and 3065 mW m/sup -2/. The 500 mW m/sup -2/ contour encloses an area of 9.4 km/sup 2/. By integrating the excess heat flux (above background) over the thermal anomaly, we deduce a thermal power loss of 12.8 MW for this geothermal system, which corresponds to a subsurface water discharge of 32 kg s/sup -1/.

  17. Geochemical Attributes and Gradients Within Geothermal Systems Define the Distribution of Specific Microbial Populations

    NASA Astrophysics Data System (ADS)

    Inskeep, W. P.; Macur, R. E.; Korf, S.; Taylor, W. P.; Ackerman, G.; Kozubal, M.; Nagy, A.

    2006-12-01

    Microorganisms in natural habitats interact with mineral surfaces in many different respects. For example, microorganisms are known to enhance the dissolution rates of some minerals via the production of organic acids and other exudates, but at the same time, may mineralize solid phases as a direct or indirect result of metabolic processes. It is also well-established that many microorganisms form biofilms on mineral surfaces, and may preferentially attach to surfaces rich in necessary nutrients or in elements used for energy conservation. In part due to the complexity of natural soil, water and sediments systems, it is generally difficult to ascertain mechanisms controlling the distribution of organisms on mineral surfaces and their role in mineral precipitation-dissolution reactions. Geothermal microbial communities are often less diverse than surface soils and sediments and offer opportunities for understanding relationships among specific microbial populations and geochemical processes that define the biogeochemical cycles of individual elements. We have investigated numerous acidic and near-neutral geothermal sites in Yellowstone National Park, and have performed a number of complimentary chemical and microbiological analyses to ascertain the role of microorganisms in S, Fe, As and Sb cycling in geothermal systems. Our results demonstrate the importance of microbiota in the formation of various Fe(III) oxide phases with variable anion chemistry, and the importance of chemolithotrophic metabolisms in Fe, S and As cycling. Where possible, these metabolisms are linked to specific microbial populations identified via molecular methods, and in some cases confirmed using isolation and characterization of individual organisms.

  18. Development of an Advanced Stimulation / Production Predictive Simulator for Enhanced Geothermal Systems

    SciTech Connect

    Pritchett, John W.

    2015-04-15

    There are several well-known obstacles to the successful deployment of EGS projects on a commercial scale, of course. EGS projects are expected to be deeper, on the average, than conventional “natural” geothermal reservoirs, and drilling costs are already a formidable barrier to conventional geothermal projects. Unlike conventional resources (which frequently announce their presence with natural manifestations such as geysers, hot springs and fumaroles), EGS prospects are likely to appear fairly undistinguished from the earth surface. And, of course, the probable necessity of fabricating a subterranean fluid circulation network to mine the heat from the rock (instead of simply relying on natural, pre-existing permeable fractures) adds a significant degree of uncertainty to the prospects for success. Accordingly, the basic motivation for the work presented herein was to try to develop a new set of tools that would be more suitable for this purpose. Several years ago, the Department of Energy’s Geothermal Technologies Office recognized this need and funded a cost-shared grant to our company (then SAIC, now Leidos) to partner with Geowatt AG of Zurich, Switzerland and undertake the development of a new reservoir simulator that would be more suitable for EGS forecasting than the existing tools. That project has now been completed and a new numerical geothermal reservoir simulator has been developed. It is named “HeatEx” (for “Heat Extraction”) and is almost completely new, although its methodology owes a great deal to other previous geothermal software development efforts, including Geowatt’s “HEX-S” code, the STAR and SPFRAC simulators developed here at SAIC/Leidos, the MINC approach originally developed at LBNL, and tracer analysis software originally formulated at INEL. Furthermore, the development effort was led by engineers with many years of experience in using reservoir simulation software to make meaningful forecasts for real geothermal

  19. Geothermal Power Potential in the Tatun Volcano Group, Taiwan

    NASA Astrophysics Data System (ADS)

    Tseng, H. H.; Song, S.

    2013-12-01

    Recent energy issues have concentrated the attention on finding alternative ones. National demands for renewable and sustainable energy increase rapidly, especially the geothermal power production, which is viewed as the most potential opportunity. This study attempts to estimate the geothermal powers in the Tatung Volcano Group (TVG), Taiwan and evaluate the possibility to develop the Enhanced Geothermal System. Tatung Volcano Group is located at the northwest part of Taiwan. It has violent volcanism during 0.8-0.20Ma, and is still active with many thermal manifestations. The young volcanic activity provides the TVG with high geothermal gradient and is well suitable for exploiting geothermal resources. Many explorations on geothermal energy have been accomplished in this area during1966-1973. They included resistivity survey, magnetic prospecting, gravity method, seismic prospecting and etc. In this study, we base on previous data and apply the probabilistic volumetric method proposed by Geotherm EX Inc., modified from the approach introduced by the USGS to evaluate the geothermal power potential in TVG. Meanwhile, use a Monte Carlo simulation technique to calculate the probability distribution of potentially recoverable energy reserves. The results show that the mean value is 270Mw, and P50 is 254Mw for 30 years, separately. Furthermore, the power potential of enhanced geothermal system in TVG is also estimated by the quantitative model proposed by Massachusetts Institute of Technology (MIT 2006). The results suggest that the mean value is 3,000 MW and P50 is 2,780 MW for 30 years, separately.

  20. Simulation of Enhanced Geothermal Systems: A Benchmarking and Code Intercomparison Study

    SciTech Connect

    Scheibe, Timothy D.; White, Mark D.; White, Signe K.; Sivaramakrishnan, Chandrika; Purohit, Sumit; Black, Gary D.; Podgorney, Robert; Boyd, Lauren W.; Phillips, Benjamin R.

    2013-06-30

    Numerical simulation codes have become critical tools for understanding complex geologic processes, as applied to technology assessment, system design, monitoring, and operational guidance. Recently the need for quantitatively evaluating coupled Thermodynamic, Hydrologic, geoMechanical, and geoChemical (THMC) processes has grown, driven by new applications such as geologic sequestration of greenhouse gases and development of unconventional energy sources. Here we focus on Enhanced Geothermal Systems (EGS), which are man-made geothermal reservoirs created where hot rock exists but there is insufficient natural permeability and/or pore fluids to allow efficient energy extraction. In an EGS, carefully controlled subsurface fluid injection is performed to enhance the permeability of pre-existing fractures, which facilitates fluid circulation and heat transport. EGS technologies are relatively new, and pose significant simulation challenges. To become a trusted analytical tool for EGS, numerical simulation codes must be tested to demonstrate that they adequately represent the coupled THMC processes of concern. This presentation describes the approach and status of a benchmarking and code intercomparison effort currently underway, supported by the U. S. Department of Energy’s Geothermal Technologies Program. This study is being closely coordinated with a parallel international effort sponsored by the International Partnership for Geothermal Technology (IPGT). We have defined an extensive suite of benchmark problems, test cases, and challenge problems, ranging in complexity and difficulty, and a number of modeling teams are applying various simulation tools to these problems. The descriptions of the problems and modeling results are being compiled using the Velo framework, a scientific workflow and data management environment accessible through a simple web-based interface.

  1. Geothermal Energy.

    ERIC Educational Resources Information Center

    Conservation and Renewable Energy Inquiry and Referral Service (DOE), Silver Spring, MD.

    An introduction to geothermal energy is provided in this discussion of: (1) how a geothermal reservoir works; (2) how to find geothermal energy; (3) where it is located; (4) electric power generation using geothermal energy; (5) use of geothermal energy as a direct source of heat; (6) geopressured reservoirs; (7) environmental effects; (8)…

  2. Recent drilling activities at the earth power resources Tuscarora geothermal power project's hot sulphur springs lease area.

    SciTech Connect

    Goranson, Colin

    2005-03-01

    Earth Power Resources, Inc. recently completed a combined rotary/core hole to a depth of 3,813 feet at it's Hot Sulphur Springs Tuscarora Geothermal Power Project Lease Area located 70-miles north of Elko, Nevada. Previous geothermal exploration data were combined with geologic mapping and newly acquired seismic-reflection data to identify a northerly tending horst-graben structure approximately 2,000 feet wide by at least 6,000 feet long with up to 1,700 feet of vertical offset. The well (HSS-2) was successfully drilled through a shallow thick sequence of altered Tertiary Volcanic where previous exploration wells had severe hole-caving problems. The ''tight-hole'' drilling problems were reduced using drilling fluids consisting of Polymer-based mud mixed with 2% Potassium Chloride (KCl) to reduce Smectite-type clay swelling problems. Core from the 330 F fractured geothermal reservoir system at depths of 2,950 feet indicated 30% Smectite type clays existed in a fault-gouge zone where total loss of circulation occurred during coring. Smectite-type clays are not typically expected at temperatures above 300 F. The fracture zone at 2,950 feet exhibited a skin-damage during injection testing suggesting that the drilling fluids may have caused clay swelling and subsequent geothermal reservoir formation damage. The recent well drilling experiences indicate that drilling problems in the shallow clays at Hot Sulphur Springs can be reduced. In addition, average penetration rates through the caprock system can be on the order of 25 to 35 feet per hour. This information has greatly reduced the original estimated well costs that were based on previous exploration drilling efforts. Successful production formation drilling will depend on finding drilling fluids that will not cause formation damage in the Smectite-rich fractured geothermal reservoir system. Information obtained at Hot Sulphur Springs may apply to other geothermal systems developed in volcanic settings.

  3. Geothermal systems within the Mammoth Corridor in Yellowstone National Park and the adjacent Corwin Springs KGRA

    USGS Publications Warehouse

    Sorey, Michael; Colvard, Elizabeth; Sturchio, N.C.

    1990-01-01

    A study of potential impacts of geothermal development in the Corwin Springs KGRA north of Yellowstone Park on thermal springs within the Park is being conducted by the U.S. Geological Survey. Thermal waters in the KGRA and at Mammoth Hot Springs, located 13 km inside the Park boundary, are high in bicarbonate and sulfate and are actively depositing travertine. These similarities and the existence of numerous regional-scale structural and stratigraphic features that could provide conduits for fluid flow at depth indicate a possible cause for concern. The objectives of this study include delineations of any hydrologic connections between these thermal waters, the level of impact of geothermal development in the event of such connections, and mitigation measures to minimize or eliminate adverse impacts. The study involves a number of geochemical, geophysical, geologic, and hydrologic techniques, but does not include any test drilling. Preliminary results suggest that thermal waters at Bear Creek Springs may contain a component of water derived from Mammoth but that thermal waters at La Duke Hot Spring do not. The total rate of thermal water that discharges in the area proposed for geothermal development (near La Duke) has been determined; restricting the net production of thermal water to rates less than this total could provide a satisfactory margin of safety for development.

  4. Geothermal energy: 1992 program overview

    SciTech Connect

    Not Available

    1993-04-01

    Geothermal energy is described in general terms with drawings illustrating the technology. A map of known and potential geothermal resources in the US is included. The 1992 program activities are described briefly. (MHR)

  5. Hydrothermal fluids vented at shallow depths at the Aeolian islands: relationships with volcanic and geothermal systems.

    NASA Astrophysics Data System (ADS)

    Italiano, Francesco; Caracausi, Antonio; Longo, Manfredi; Maugeri, Roberto; Paonita, Antonio

    2010-05-01

    lower values detected in venting gases from active volcanoes (e.g. Vulcano and Panarea). The explanation of such a difference is not related to the volcanic activity at all, but to the parent mantle that in the western side looks to be less contaminated compared to the eastern side. Crustal contamination has been invoked by several authors as the main factor that caused the dramatic 3He/4He decrease. Although the parent mantle produced magmas with different isotopic signature, the gas phase looks similar. To explain the results of the chemical analyses it is proposed that similar deep boundary conditions (pressure, temperature, oxidation level) act as buffers for the chemical composition of the venting gases. With the aim of investigating their origin, estimations of the deep equilibration conditions have been carried out. The reactive compounds detected in the sampled gases, largely used for geothermometric and geobarometric considerations of hydrothermal fluids were used in a system based on the CH4-CO-CO2 contents assuming the presence of a boiling aqueous solution. The equilibrium constants of the adopted reactions are a function of temperature and oxygen fugacity, being the latter buffered by the mineral assemblage of the host rocks. Due to the similarity in the chemical composition of the gases vented at all the islands, a theoretical model developed to interpret the chemical composition of the gases released at Panarea during the last volcanic crisis is here applied. The results have shown that geothermal boiling systems are detectable at all the islands with temperatures up to 350°C. The adopted geo-thermobarometric system is more sensitive to the contents of CO and CH4 than that of CO2, implying that although GWI induce modifications in the chemical composition, the estimated equilibrium temperatures do not change very much for variations of the CO2 content in the range of several volume percent, thus, whether or not the gaseous mixture underwent GWI. Moreover

  6. Current California legislative and regulatory activity impacting geothermal hydrothermal commercialization: monitoring report No. 2. Report No. 1020

    SciTech Connect

    Not Available

    1980-04-20

    The progress of four bills relating to geothermal energy is reported. The current regulatory activities of the California Energy Commission, the Lake County Planning Commission/Lake County Air Pollution Control District, the Governor's Office of Planning and Research, the State Lands' Commission, and the California Public Utilities Commission are reviewed. (MHR)

  7. US National Geothermal Data System: Web feature services and system operations

    NASA Astrophysics Data System (ADS)

    Richard, Stephen; Clark, Ryan; Allison, M. Lee; Anderson, Arlene

    2013-04-01

    The US National Geothermal Data System is being developed with support from the US Department of Energy to reduce risk in geothermal energy development by providing online access to the body of geothermal data available in the US. The system is being implemented using Open Geospatial Consortium web services for catalog search (CSW), map browsing (WMS), and data access (WFS). The catalog now includes 2427 registered resources, mostly individual documents accessible via URL. 173 WMS and WFS services are registered, hosted by 4 NGDS system nodes, as well as 6 other state geological surveys. Simple feature schema for interchange formats have been developed by an informal community process in which draft content models are developed based on the information actually available in most data provider's internal datasets. A template pattern is used for the content models so that commonly used content items have the same name and data type across models. Models are documented in Excel workbooks and posted for community review with a deadline for comment; at the end of the comment period a technical working group reviews and discusses comments and votes on adoption. When adopted, an XML schema is implemented for the content model. Our approach has been to keep the focus of each interchange schema narrow, such that simple-feature (flat file) XML schema are sufficient to implement the content model. Keeping individual interchange formats simple, and allowing flexibility to introduce new content models as needed have both assisted in adoption of the service architecture. One problem that remains to be solved is that off-the-shelf server packages (GeoServer, ArcGIS server) do not permit configuration of a normative schema location to be bound with XML namespaces in instance documents. Such configuration is possible with GeoServer using a more complex deployment process. XML interchange format schema versions are indicated by the namespace URI; because of the schema location

  8. Hydrogeochemistry and preliminary reservoir model of the Platanares Geothermal System, Honduras, Central America

    SciTech Connect

    Goff, F.; Shevenell, L.; Janik, C.J.; Truesdell, A.H.; Grigsby, C.O.; Paredes, R.

    1986-01-01

    A detailed hydrogeochemical investigation has been performed at Platanares, Honduras in preparation for shallow geothermal exploration drilling. Platanares is not associated with any Quaternary volcanism but lies in a tectonic zone of late Tertiary to Quaternary extension. Thermal fluids are characterized by pH between 7 and 10, Cl < 40 mg/l, HCO/sub 3/ > SO/sub 4/ > Cl, B less than or equal to 17 mg/l, Li less than or equal to 4 mg/l and As less than or equal to 1.25 mg/l. Various geochemical indicators show that mixing of hot and cold end-member fluids is an important hydrologic process at this site. Geothermometers indicate the geothermal system equilibrated at roughly 225/sup 0/C while trace element chemistry indicates the reservoir resides in Cretaceous red beds of the Valle de Angeles Group. Based on the discharge rates of thermal features, the minimum power output of the Platanares geothermal site is about 45 MW (thermal).

  9. Geologic and hydrologic research on the Moana geothermal system, Washoe County, Nevada

    SciTech Connect

    Flynn, T.; Ghusn, G. Jr.

    1983-12-01

    The Moana geothermal area is the largest single low- to moderate-temperature geothermal resource in the State of Nevada presently employed for direct-use applications. Approximately 150 individual wells, representing a total estimated investment of $5 to $7 million, are presently used to provide heat ahd hot water to more than 130 private residences, several churches and two large motels. Although most of the wells are constructed to meet the heating needs of individual homes, a large-scale district space heating system, designed to supply heat to 60 houses from a single well, is now being developed. Usable temperatures range from 50 to 99/sup 0/C (120 to 210/sup 0/F); well depths range from 60 to 400 m (100 to 1300 ft). The number of new wells coming on-line in Moana is two to three per month. Development of the resource has been largely unregulated and questions dealing with reported reservoir temperature and water level declines, loss of artesian flow, and fluid disposal have recently surfaced. In October 1982, a geologic and hydrologic research program began that was designed to provide detailed geothermal reservoir data to present or prospective developers. The program combines geophysical, geochemical, and geological surveys of the Moana resource area with a drilling program for 5 monitor/observation wells. Data from this program are supplied directly to developers as well as state and local government agencies to provide for prudent resource development. This paper summarizes the program elements and describes the present status.

  10. Improved Detection of Microearthquakes: Application of Matched Field Processing (MFP) to Traditional and Enhanced Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Templeton, D. C.; Harris, D.; Goebel, M.

    2013-12-01

    We investigate the microseismicity in both traditional and Enhanced Geothermal Systems (EGS) and compare the temporal distribution of microseismic events to well fluid injection data. We apply the empirical and model-based Matched Field Processing (MFP) methods to continuous seismic data from the Salton Sea geothermal field and the DOE Newberry EGS site. MFP is a non-traditional event detection method that can identify more and smaller events than traditional detection methods alone. The empirical MFP method uses known catalog events as master templates to identify new microearthquakes while the model-based MFP method uses synthetic sources computed across a subsurface 3D grid as master templates. Salton Sea data between January 2008 and December 2011 was downloaded off the SCEDC website and high-quality master events were identified from the online catalog. We created empirical matched field steering vector calibrations for 7 three-component stations within the Salton Sea Geothermal Field. The original Salton Sea earthquake catalog identified 4202 events. When we applied the empirical MFP technique to the same data, we identified 5005 additional events (~119% more events). We compare the results from this traditional geothermal area with results obtained from the Newberry EGS site, for which we have 8 three-component stations. The Newberry catalog originally identified 204 events in 3 months while the MFP technique identified 249 additional events (~122% more events). We will compare the results from using the empirical MFP method at the Newberry EGS site with results obtained from using model-based master templates. Additionally, we compare the number of events in the improved earthquake catalogs with available fluid injection data. This work is performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  11. The evolution of volcano-hosted geothermal systems based on deep wells from Karaha-Telaga Bodas, Indonesia

    USGS Publications Warehouse

    Moore, J.N.; Allis, R.G.; Nemcok, M.; Powell, T.S.; Bruton, C.J.; Wannamaker, P.E.; Raharjo, I.B.; Norman, D.I.

    2008-01-01

    Temperature and pressure surveys, fluid samples, and petrologic analyses of rock samples from deep drill holes at the Karaha - Telaga Bodas geothermal field on the volcanic ridge extending northward from Galunggung Volcano, West Java, have provided a unique opportunity to characterize the evolution of an active volcano-hosted geothermal system. Wells up to 3 km in depth have encountered temperatures as high as 353??C and a weakly altered granodiorite that intruded to within 2 to 3 km of the surface. The intrusion is shallowest beneath the southern end of the field where an acid lake overlies a nearly vertical low resistivity structure (<10 ohm-m) defined by magnetotelluric measurements. This structure is interpreted to represent a vapor-dominated chimney that provides a pathway to the surface for magmatic gases. Four distinct hydrothermal mineral assemblages document the evolution of the geothermal system and the transition from liquid- to vapor-dominated conditions. The earliest assemblage represents the initial liquid-dominated system generated during emplacement of the granodiorite between 5910 ?? 76 and 4200 ?? 150 y BP. Tourmaline, biotite, actinolite, epidote and clay minerals were deposited contemporaneously at progressively greater distances from the intrusive contact (assemblage 1). At 4200 ?? 150 y BP, flank collapse and the formation of the volcano's crater, Kawah Galunggung, resulted in catastrophic decompression and boiling of the hydrothermal fluids. This event initiated development of the modern vapor-dominated regime. Chalcedony and then quartz were deposited as the early low salinity liquids boiled (assemblage 2). Both vapor- and liquid-rich fluid inclusions were trapped in the quartz crystals. Liquid-rich fluid inclusions from the southern part of the field record salinities ranging from 0 to 26 weight percent NaCl- CaCl2 equivalent and locally contain fluorite daughter crystals. We suggest, based on temperature-salinity relationships and evidence

  12. Review of international geothermal activities and assessment of US industry opportunities: Summary report

    SciTech Connect

    Not Available

    1987-08-01

    This report summarizes a study initiated to review and assess international developments in the geothermal energy field and to define business opportunities for the US geothermal industry. The report establishes data bases on the status of worldwide geothermal development and the competitiveness of US industry. Other factors identified include existing legislation, tax incentives, and government institutions or agencies and private sector organizations that promote geothermal exports. Based on the initial search of 177 countries and geographic entities, 71 countries and areas were selected as the most likely targets for the expansion of the geothermal industry internationally. The study then determined to what extent their geothermal resource had been developed, what countries had aided or participated in this development, and what plans existed for future development. Data on the energy, economic, and financial situations were gathered.

  13. Review of international geothermal activities and assessment of US industry opportunities: Final report

    SciTech Connect

    Not Available

    1987-08-01

    This study was initiated to review and assess international developments in the geothermal energy field and to define business opportunities for the US geothermal industry. The report establishes data bases on the status of worldwide geothermal development and the competitiveness of US industry. Other factors identified include existing legislation, tax incentives, and government institutions or agencies and private sector organizations that promote geothermal exports. Based on the initial search of 177 countries and geographic entities, 71 countries and areas were selected as the most likely targets for the expansion of the geothermal industry internationally. The study then determined to what extent their geothermal resource had been developed, what countries had aided or participated in this development, and what plans existed for future development. Data on the energy, economic, and financial situations were gathered.

  14. Review of International Geothermal Activities and Assessment of US Industry Opportunites: Final Report

    SciTech Connect

    1987-08-01

    This report contains detailed summaries, with bibliographies, of past, present, and planned geothermal development in 71 selected countries and areas. The report gives a pretty good description of types of work that had been done in each country by the mid 1980s, but does not tell much about which geothermal-provider country did the work. There are maps for most of the countries. There are numbers for market factors, but not for estimated geothermal potential. The information in this document has been superceded by the country summaries in the World Geothermal Congress Transactions of 1995, 2000, and 2005. This report was prepared by Meridian Corporation, Alexandria, VA. (DJE 2005)

  15. Recirculation System for Geothermal Energy Recovery in Sedimentary Formations: Laboratory Experiments and Numerical Simulations

    NASA Astrophysics Data System (ADS)

    Elkhoury, J. E.; Detwiler, R. L.; Serajian, V.; Bruno, M. S.

    2012-12-01

    Geothermal energy resources are more widespread than previously thought and have the potential for providing a significant amount of sustainable clean energy worldwide. In particular, hot permeable sedimentary formations provide many advantages over traditional geothermal recovery and enhanced geothermal systems in low permeability crystalline formations. These include: (1) eliminating the need for hydraulic fracturing, (2) significant reduction in risk for induced seismicity, (3) reducing the need for surface wastewater disposal, (4) contributing to decreases in greenhouse gases, and (5) potential use for CO2 sequestration. Advances in horizontal drilling, completion, and production technology from the oil and gas industry can now be applied to unlock these geothermal resources. Here, we present experimental results from a laboratory scale circulation system and numerical simulations aimed at quantifying the heat transfer capacity of sedimentary rocks. Our experiments consist of fluid flow through a saturated and pressurized sedimentary disc of 23-cm diameter and 3.8-cm thickness heated along its circumference at a constant temperature. Injection and production ports are 7.6-cm apart in the center of the disc. We used DI de-aired water and mineral oil as working fluids and explored temperatures from 20 to 150 oC and flow rates from 2 to 30 ml/min. We performed experiments on sandstone samples (Castlegate and Kirby) with different porosity, permeability and thermal conductivity to evaluate the effect of hydraulic and thermal properties on the heat transfer capacity of sediments. The producing fluid temperature followed an exponential form with time scale transients between 15 and 45 min. Steady state outflow temperatures varied between 60% and 95% of the set boundary temperature, higher percentages were observed for lower temperatures and flow rates. We used the flow and heat transport simulator TOUGH2 to develop a numerical model of our laboratory setting. Given

  16. Design of a geothermal monitoring network in a coastal area and the evaluation system

    NASA Astrophysics Data System (ADS)

    Ohan Shim, Byoung; Lee, Chulwoo; Park, Chanhee

    2016-04-01

    In Seockmodo Island (area of 48.2 km2) located at the northwest of South Korea, a renewable energy development project to install photovoltaic 136 kW and geothermal 516.3 kW is initiated. Since the 1990s, more than 20 deep geothermal wells for hot springs, greenhouse and aquaculture have been developed along coastal areas. The outflow water of each site has the pumping capacity between 300 and 4,800 m3/day with the salinity higher than 20,000 mg/l, and the maximum temperature shows 70 ?C. Because of the required additional well drillings, the increased discharge rate can cause serious seawater intrusion into freshwater aquifers, which supply groundwater for drinking and living purposes from 210 wells. In order to manage the situation, advanced management skills are required to maintain the balance between geothermal energy development and water resources protection. We designed real-time monitoring networks with monitoring stations for the sustainable monitoring of the temperature and salinity. Construction of borehole temperature monitoring for deep and shallow aquifer consists with the installation of automated temperature logging system and cellular telemetry for real-time data acquisition. The DTS (distributed temperature sensing) system and fiber optic cables will be installed for the logging system, which has enough temperature resolution and accuracy. The spatial distribution and the monitoring points can be determined by geological and hydrological situations associated with the locations of current use and planned facilities. The evaluation of the temperature and salinity variation will be conducted by the web-based monitoring system. The evaluation system will be helpful to manage the balance between the hot water development and the fresh water resources conservation.

  17. Naturally occurring arsenic in terrestrial geothermal systems of western Anatolia, Turkey: potential role in contamination of freshwater resources.

    PubMed

    Bundschuh, Jochen; Maity, Jyoti Prakash; Nath, Bibhash; Baba, Alper; Gunduz, Orhan; Kulp, Thomas R; Jean, Jiin-Shuh; Kar, Sandeep; Yang, Huai-Jen; Tseng, Yu-Jung; Bhattacharya, Prosun; Chen, Chien-Yen

    2013-11-15

    Arsenic (As) contamination in terrestrial geothermal systems has been identified in many countries worldwide. Concentrations higher than 0.01 mg/L are detrimental to human health. We examined potential consequences for As contamination of freshwater resources based on hydrogeochemical investigations of geothermal waters in deep wells and hot springs collected from western Anatolia, Turkey. We analyzed samples for major ions and trace element concentrations. Temperature of geothermal waters in deep wells showed extreme ranges (40 and 230 °C), while, temperature of hot spring fluids was up to 90 °C. The Piper plot illustrated two dominant water types: Na-HCO3(-) type for geothermal waters in deep wells and Ca-HCO3(-) type for hot spring fluids. Arsenic concentration ranged from 0.03 to 1.5mg/L. Dominance of reduced As species, i.e., As(III), was observed in our samples. The Eh value ranged between -250 and 119 mV, which suggests diverse geochemical conditions. Some of the measured trace elements were found above the World Health Organization guidelines and Turkish national safe drinking water limits. The variation in pH (range: 6.4-9.3) and As in geothermal waters suggest mixing with groundwater. Mixing of geothermal waters is primarily responsible for contamination of freshwater resources and making them unsuitable for drinking or irrigation.

  18. Geothermal Progress Monitor 12

    SciTech Connect

    1990-12-01

    Some of the more interesting articles in this GPM are: DOE supporting research on problems at The Geysers; Long-term flow test of Hot Dry Rock system (at Fenton Hill, NM) to begin in Fiscal Year 1992; Significant milestones reached in prediction of behavior of injected fluids; Geopressured power generation experiment yields good results. A number of industry-oriented events and successes are reported, and in that regard it is noteworthy that this report comes near the end of the most active decade of geothermal power development in the U.S. There is a table of all operating U.S. geothermal power projects. The bibliography of research reports at the end of this GPM is useful. (DJE 2005)

  19. Geothermal drilling technology update

    SciTech Connect

    Glowka, D.A.

    1997-04-01

    Sandia National Laboratories conducts a comprehensive geothermal drilling research program for the US Department of Energy, Office of Geothermal Technologies. The program currently includes seven areas: lost circulation technology, hard-rock drill bit technology, high-temperature instrumentation, wireless data telemetry, slimhole drilling technology, Geothermal Drilling Organization (GDO) projects, and drilling systems studies. This paper describes the current status of the projects under way in each of these program areas.

  20. Geothermal drilling research overview

    SciTech Connect

    Glowka, D.A.

    1996-04-10

    Sandia conducts a comprehensive geothermal drilling research program for the US Department of Energy. The program currently consists of eight program areas: lost circulation technology; advanced synthetic-diamond drill bit technology, high-temperature logging technology; acoustic technology; slimhole drilling technology; drilling systems studies; Geothermal Drilling Organization projects; and geothermal heat pump technology. This paper provides justification and describes the projects underway in each program area.

  1. Analysis of historical and current drawdown and production data from the Boise geothermal system. Research technical completion report

    SciTech Connect

    Waag, C.J.; Wood, S.H.

    1987-08-01

    Since 1982 withdrawals from the Boise Geothermal aquifer system have increased from less than 300 million to over 600 million gals/yr. Prior to 1983 the system appears to have been in or near equilibrium. Current production levels exceed the ability of the system to recover on an annual basis. Potentiometric levels within the aquifer are declining at increasing rates and a new equilibrium level is not evident. Thus, exploitation of the geothermal aquifer is currently outstripping knowledge and understanding of the aquifer. It is time to give serious consideration to placing a temporary moratorium on further development and production from the system until a better understanding of its capacity is achieved.

  2. Materials for geothermal production

    SciTech Connect

    Kukacka, L.E.

    1992-01-01

    Advances in the development of new materials continue to be made in the geothermal materials project. Many successes have already been accrued and the results used commercially. In FY 1991, work was focused on reducing well drilling, fluid transport and energy conversion costs. Specific activities performed included lightweight CO{sub 2}-resistant well cements, thermally conductive and scale resistant protective liner systems, chemical systems for lost circulation control, corrosion mitigation in process components at The Geysers, and elastomer-metal bonding systems. Efforts to transfer the technologies developed in these efforts to other energy-related sectors of the economy continued and considerable success was achieved.

  3. Application of seismic tomographic techniques in the investigation of geothermal systems

    SciTech Connect

    Romero, A.E. Jr.

    1995-05-01

    The utility of microearthquake data for characterizing the Northwest Geysers geothermal field and the Long Valley Caldera (LVC) was investigated. Three-dimensional (3-D) P- and S-wave seismic velocity models were estimated for the Coldwater Creek Steam Field (CCSF) in the Northwest Geysers region. Hypocenters relocated using these 3-D models appear to be associated with the steam producing zone, with a deeper cluster of hypocenters beneath an active injection well. Spatial and temporal patterns of seismicity exhibit strong correlation with geothermal exploitation. A 3-D differential attenuation model was also developed for the CCSF from spectral ratios corrected for strong site effects. High-velocity anomalies and low attenuation in the near surface correspond to Franciscan metagraywacke and greenstone units. Microearthquakes recorded at seismographic stations located near the metagraywacke unit exhibit high corner frequencies. Low-velocity anomalies and higher attenuation in the near surface are associated with sections of Franciscan melange. Near-surface high attenuation and high Vp/Vs are interpreted to indicate liquid-saturated regions affected by meteoric recharge. High attenuation and low Vp/Vs marks the steam producing zone, suggesting undersaturation of the reservoir rocks. The extent of the high attenuation and low Vp/Vs anomalies suggest that the CCSF steam reservoir may extend northwestward beyond the known producing zone. This study concludes that microearthquake monitoring may be useful as an active reservoir management tool. Seismic velocity and attenuation structures as well as the distribution of microearthquake activity can be used to identify and delineate the geothermal reservoir, while temporal variations in these quantities would be useful in tracking changes during exploitation.

  4. Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade

    SciTech Connect

    Liu, Xiaobing

    2014-06-01

    High initial cost and lack of public awareness of ground source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights findings of a case study of one of the ARRA-funded GSHP demonstration projects, which is a heating only central GSHP system using shallow aquifer as heat source and installed at a warehouse and truck bay at Kalispell, MT. This case study is based on the analysis of measured performance data, utility bills, and calculations of energy consumptions of conventional central heating systems for providing the same heat outputs as the central GSHP system did. The evaluated performance metrics include energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of GSHP system compared with conventional heating systems. This case study also identified areas for reducing uncertainties in performance evaluation, improving operational efficiency, and reducing installed cost of similar GSHP systems in the future. Publication of ASHRAE at the annual conference in Seattle.

  5. Flathead Electric Cooperative Facility Geothermal Heat Pump System Upgrade.

    SciTech Connect

    Liu, Xiaobing

    2014-06-01

    High initial cost and lack of public awareness of ground source heat pump (GSHP) technology are the two major barriers preventing rapid deployment of this energy saving technology in the United States. Under the American Recovery and Reinvestment Act (ARRA), 26 GSHP projects have been competitively selected and carried out to demonstrate the benefits of GSHP systems and innovative technologies for cost reduction and/or performance improvement. This paper highlights findings of a case study of one of the ARRA-funded GSHP demonstration projects, which is a heating only central GSHP system using shallow aquifer as heat source and installed at a warehouse and truck bay at Kalispell, MT. This case study is based on the analysis of measured performance data, utility bills, and calculations of energy consumptions of conventional central heating systems for providing the same heat outputs as the central GSHP system did. The evaluated performance metrics include energy efficiency of the heat pump equipment and the overall GSHP system, pumping performance, energy savings, carbon emission reductions, and cost-effectiveness of GSHP system compared with conventional heating systems. This case study also identified areas for reducing uncertainties in performance evaluation, improving operational efficiency, and reducing installed cost of similar GSHP systems in the future. Publication of ASHRAE at the annual conference in Seattle June 2014.

  6. Fracture Propagation and Permeability Change under Poro-thermoelastic Loads & Silica Reactivity in Enhanced Geothermal Systems

    SciTech Connect

    Ahmad Ghassemi

    2009-10-01

    Geothermal energy is recovered by circulating water through heat exchange areas within a hot rock mass. Geothermal reservoir rock masses generally consist of igneous and metamorphic rocks that have low matrix permeability. Therefore, cracks and fractures play a significant role in extraction of geothermal energy by providing the major pathways for fluid flow and heat exchange. Therefore, knowledge of the conditions leading to formation of fractures and fracture networks is of paramount importance. Furthermore, in the absence of natural fractures or adequate connectivity, artificial fractures are created in the reservoir using hydraulic fracturing. Multiple fractures are preferred because of the large size necessary when using only a single fracture. Although the basic idea is rather simple, hydraulic fracturing is a complex process involving interactions of high pressure fluid injections with a stressed hot rock mass, mechanical interaction of induced fractures with existing natural fractures, and the spatial and temporal variations of in-situ stress. As a result, it is necessary to develop tools that can be used to study these interactions as an integral part of a comprehensive approach to geothermal reservoir development, particularly enhanced geothermal systems. In response to this need we have developed advanced poro-thermo-chemo-mechanical fracture models for rock fracture research in support of EGS design. The fracture propagation models are based on a regular displacement discontinuity formulation. The fracture propagation studies include modeling interaction of induced fractures. In addition to the fracture propagation studies, two-dimensional solution algorithms have been developed and used to estimate the impact of pro-thermo-chemical processes on fracture permeability and reservoir pressure. Fracture permeability variation is studied using a coupled thermo-chemical model with quartz reaction kinetics. The model is applied to study quartz precipitation

  7. Design and testing of fish drier system utilizing geothermal energy resource in Ie Suum, Aceh Besar

    NASA Astrophysics Data System (ADS)

    Mubarak, Amir Zaki; Maulana, M. Ilham; Syuhada, Ahmad

    2016-03-01

    In an effort to increase the value of fish produced by the community in Krueng Raya Sub-district, it has been designed and tested a fish drier system utilizing geothermal energy resource in IeSuum Village, Krueng Raya Sub-district, Aceh Besar District. The geothermal energy is in the form of hot water with the temperature range is between 86 and 86.4 °C. Based on the design consideration, it is used a terraced rack type drier system. The drier system consists of a heat exchanger, drying chamber, and a blower to blow the air. Hot water from the geothermal source is passed into the heat exchanger to increase the air temperature outside it. The air is then blown into the drying chamber. Based on the design analysis is obtained that to dry 200 kg of fish in 24 hour, it is required a drying chamber with 1m long, 1 m width and 0.4 m high, the temperature of hot water entering the exchanger is 80 °C and the temperature of the air entering the drying chamber is maintained at 60°C. The average time required to dry fish till 10% of water level is 18-20 jam. The research is then continued by developing and testing the drying system with three layer rack to put in the fish. From the experimental result is obtained that the average water temperature flows out of the chamber is in the range of 76-78 °C and the temperature in the chamber is in the range of 57-62 °C. In addition, the weight of the fish, which initially is 20 kg, becomes12 kg in average after 18 hours drying process.

  8. A brine interface in the Salton Sea Geothermal System, California: Fluid geochemical and isotopic characteristics

    SciTech Connect

    Williams, A.E.; McKibben, M.A. )

    1989-08-01

    Data from 71 geothermal production intervals in 48 wells from the Salton Sea Geothermal System (SSGS) indicate that fluids in that system cluster into two distinct populations in terms of their salinity and their stable isotopic compositions. The distinctive, hot, hypersaline brine (typically >20 wt% total dissolved solids) for which the SSGS is known is overlain by a cooler (<260{degree}C) fluid with distinctly lower salinity (typically <10 wt% total dissolved solids). Hypersaline brines have high and rather consistent {sup 18}O shifts produced by water-rock interaction and have a very narrow range in {delta}D values. Low TDS fluids, on the other hand, show a wide range in both {delta}D and {delta}{sup 18}O. production of both types of fluid from closely spaced geothermal wells in many regions of the SSGS indicates that a relatively sharp salinity interface exists over much of the field. The fluid interface typically cross-cuts sedimentary bedding but is consistently found where reservoir temperatures are approximately 260{degree}C. At these temperatures, hypersaline brines have densities of approximately 1.0 gm/cm{sup 3}, while the low TDS fluids have densities as low as 0.85 gm/cm{sup 3}. This stable, density-stratified interface acts as a barrier to convective heat and mass transfer in the SSGS, isolating the hypersaline reservoir from overlying dilute fluids. A lithologic cap implied by previous SSGS models is unnecessary in such a stratified system since heat and mass transfer across the interface must occur by slow conductive, diffusional and interface mixing processes regardless of local permeability.

  9. Dixie Valley Engineered Geothermal System Exploration Methodology Project, Baseline Conceptual Model Report

    DOE Data Explorer

    Iovenitti, Joe

    2014-01-02

    The Engineered Geothermal System (EGS) Exploration Methodology Project is developing an exploration approach for EGS through the integration of geoscientific data. The Project chose the Dixie Valley Geothermal System in Nevada as a field laboratory site for methodology calibration purposes because, in the public domain, it is a highly characterized geothermal system in the Basin and Range with a considerable amount of geoscience and most importantly, well data. The overall project area is 2500km2 with the Calibration Area (Dixie Valley Geothermal Wellfield) being about 170km2. The project was subdivided into five tasks (1) collect and assess the existing public domain geoscience data; (2) design and populate a GIS database; (3) develop a baseline (existing data) geothermal conceptual model, evaluate geostatistical relationships, and generate baseline, coupled EGS favorability/trust maps from +1km above sea level (asl) to -4km asl for the Calibration Area at 0.5km intervals to identify EGS drilling targets at a scale of 5km x 5km; (4) collect new geophysical and geochemical data, and (5) repeat Task 3 for the enhanced (baseline + new ) data. Favorability maps were based on the integrated assessment of the three critical EGS exploration parameters of interest: rock type, temperature and stress. A complimentary trust map was generated to compliment the favorability maps to graphically illustrate the cumulative confidence in the data used in the favorability mapping. The Final Scientific Report (FSR) is submitted in two parts with Part I describing the results of project Tasks 1 through 3 and Part II covering the results of project Tasks 4 through 5 plus answering nine questions posed in the proposal for the overall project. FSR Part I presents (1) an assessment of the readily available public domain data and some proprietary data provided by Terra-Gen Power, LLC, (2) a re-interpretation of these data as required, (3) an exploratory geostatistical data analysis, (4

  10. Influence of time on metamorphism of sedimentary organic matter in liquid-dominated geothermal systems, western North America.

    USGS Publications Warehouse

    Barker, C.E.

    1983-01-01

    Reflectance data of sedimentary organic matter samples from six liquid-dominated geothermal systems are strongly temperature-dependent. Geologic evidence indicates that reaction duration ranges from approx 103 to 106 yr in these systems that appear to have near-maximum temperatures. The strong temperature dependence of vitrinite reflectance indicates that after about 104 yr, reaction duration has little or no influence on metamorphism of organic matter in liquid-dominated geothermal systems. These data indicate that vitrinite reflectance can be used to determine the maximum temperature reached in hot sedimentary basins of moderate longevity. -after Author

  11. GEOTHERM user guide

    USGS Publications Warehouse

    Swanson, James R.

    1977-01-01

    GEOTHERM is a computerized geothermal resources file developed by the U.S. Geological Survey. The file contains data on geothermal fields, wells, and chemical analyses from the United states and international sources. The General Information Processing System (GIPSY) in the IBM 370/155 computer is used to store and retrieve data. The GIPSY retrieval program contains simple commands which can be used to search the file, select a narrowly defined subset, sort the records, and output the data in a variety of forms. Eight commands are listed and explained so that the GEOTHERM file can be accessed directly by geologists. No programming experience is necessary to retrieve data from the file.

  12. Cost Analysis of Environmental Control Systems applicable to Geothermal Energy Development

    SciTech Connect

    1982-08-01

    This report provides an engineering performance and cost correlations from which user could estimate costs of mitigating principal emissions from geothermal power systems. Hydrogen sulfide abatement describes four processes; Iron catalyst, Stretford, EIC, and Dow oxygenation process. Wastewater treatments include: Chemical precipitation, Evaporation ponds, Injection without pretreatment, and Injection with pretreatment. Process and cost estimates are given for Best Case, Most Probable Case, and Worst Case 50 MWe power plant. The cases may be confusing since the worst case has the lowest resource temperature, but the highest loads to mitigate. (DJE 2005)

  13. Using Estimated Risk to Develop Stimulation Strategies for Enhanced Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Douglas, John; Aochi, Hideo

    2014-08-01

    Enhanced geothermal systems (EGS) are an attractive source of low-carbon electricity and heating. Consequently, a number of tests of this technology have been made during the past couple of decades, and various projects are being planned or under development. EGS work by the injection of fluid into deep boreholes to increase permeability and hence allow the circulation and heating of fluid through a geothermal reservoir. Permeability is irreversibly increased by the generation of microseismicity through the shearing of pre-existing fractures or fault segments. One aspect of this technology that can cause public concern and consequently could limit the widespread adoption of EGS within populated areas is the risk of generating earthquakes that are sufficiently large to be felt (or even to cause building damage). Therefore, there is a need to balance stimulation and exploitation of the geothermal reservoir through fluid injection against the pressing requirement to keep the earthquake risk below an acceptable level. Current strategies to balance these potentially conflicting requirements rely on a traffic light system based on the observed magnitudes of the triggered earthquakes and the measured peak ground velocities from these events. In this article we propose an alternative system that uses the actual risk of generating felt (or damaging) earthquake ground motions at a site of interest (e.g. a nearby town) to control the injection rate. This risk is computed by combining characteristics of the observed seismicity of the previous 6 h with a (potentially site-specific) ground motion prediction equation to obtain a real-time seismic hazard curve; this is then convolved with the derivative of a (potentially site-specific) fragility curve. Based on the relation between computed risk and pre-defined acceptable risk thresholds, the injection is increased if the risk is below the amber level, decreased if the risk is between the amber and red levels, or stopped

  14. Low-Temperature Enhanced Geothermal System using Carbon Dioxide as the Heat-Transfer Fluid

    SciTech Connect

    Eastman, Alan D.

    2014-07-24

    This report describes work toward a supercritical CO2-based EGS system at the St. Johns Dome in Eastern Arizona, including a comprehensive literature search on CO2-based geothermal technologies, background seismic study, geological information, and a study of the possible use of metal oxide heat carriers to enhance the heat capacity of sCO2. It also includes cost estimates for the project, and the reasons why the project would probably not be cost effective at the proposed location.

  15. Temporary Bridging Agents for use in Drilling and Completion of Enhanced Geothermal Systems

    SciTech Connect

    Watters, Larry; Watters, Jeff; Sutton, Joy; Combs, Kyle; Bour, Daniel; Petty, Susan; Rose, Peter; Mella, Michael

    2011-12-21

    CSI Technologies, in conjunction with Alta Rock Energy and the University of Utah have undergone a study investigating materials and mechanisms with potential for use in Enhanced Geothermal Systems wells as temporary diverters or lost circulation materials. Studies were also conducted with regards to particle size distribution and sealing effectiveness using a lab-scale slot testing apparatus to simulate fractures. From the slot testing a numerical correlation was developed to determine the optimal PSD for a given fracture size. Field trials conducted using materials from this study were also successful.

  16. A review of progress in understanding the fluid geochemistry of the Cerro Prieto geothermal system

    USGS Publications Warehouse

    Truesdell, A.H.; Nehring, N.L.; Thompson, J.M.; Janik, C.J.; Coplen, T.B.

    1984-01-01

    Fluid geochemistry has played a major role in our present understanding of the Cerro Prieto geothermal system. Fluid chemical and isotopic compositions have been used to indicate the origin of water, salts and gases, original subsurface temperature and fluid flow, fluid-production mechanisms, and production-induced aquifer boiling and cold-water entry. The extensive geochemical data and interpretations for Cerro Prieto published from 1964 to 1981 are reviewed and discussed. Fluid geochemistry must continue to play an important role in the further development of the Cerro Prieto field. ?? 1984.

  17. Operations research and systems analysis of geopressured-geothermal energy in Louisiana. Final report for the period June 1, 1978-August 31, 1979

    SciTech Connect

    Johnson, A.E. Jr.

    1980-11-01

    The primary purpose was to provide a projection of the probable future contribution of the geopressured-geothermal energy resource in Louisiana to the overall energy requirements of the nation. A number of associated objectives were emphasized: namely, development of the tools and methodology for performing economic analyses, application of these tools to specific prospects about which adequate resource assessments have been made, identification of the impediments to resource development, and socio-economic analysis of the impact of development of the resource on these specific prospects. An overview of the geopressured-geothermal resource activities in Louisiana is provided first, followed by a detailed discussion and review of the achievements of this project. Finally the major conclusions and findings of this project with respect to commercial viability, impediments, and social and economic impact are presented, and recommendations are made for future systems analysis work.

  18. Continuous on-line steam quality monitoring system of the Bacman Geothermal Production Field, Philippines

    SciTech Connect

    Solis, R.P.; Chavez, F.C.; Garcia, S.E.

    1997-12-31

    In any operating geothermal power plant, steam quality is one of the most important parameters being monitored. In the Bacon-Manito Geothermal Production Field (BGPF), an online steam quality monitoring system have been installed in two operating power plants which provides an accurate, efficient and continuous real-time data which is more responsive to the various requirements of the field operation. The system utilizes sodium as an indicator of steam purity. Sodium concentration is read by the flame photometer located at the interface after aspirating a sample of the condensed steam through a continuous condensate sampler. The condensate has been degassed through a condensate-NCG separator. The flame photometer analog signal is then converted by a voltage-to-current converter/transmitter and relayed to the processor which is located at the control center through electrical cable to give a digital sodium concentration read-out at the control panel. The system features a high and high-high sodium level alarm, a continuous strip-chart recorder and a central computer for data capture, retrieval, and processing for further interpretation. Safety devices, such as the flame-off indicator at the control center and the automatic fuel cut-off device along the fuel line, are incorporated in the system.

  19. Imperial County geothermal development. Quarterly report, January 1-March 31, 1982

    SciTech Connect

    Not Available

    1982-03-31

    The activities of the Geothermal Office are reported including: important geothermal events, geothermal waste disposal, grant applications to the California Energy Commission, the planned geothermal development meeting, and other geothermal planning activities. The activities of the Geothermal Planner include processing of applications for geothermal permits, processing of environmental impact reports, and other geothermal planning activities. The progress on the VTN Corporation direct heat study is discussed.

  20. Geothermal Water Use: Life Cycle Water Consumption, Water Resource Assessment, and Water Policy Framework

    SciTech Connect

    Schroeder, Jenna N.

    2014-06-10

    This report examines life cycle water consumption for various geothermal technologies to better understand factors that affect water consumption across the life cycle (e.g., power plant cooling, belowground fluid losses) and to assess the potential water challenges that future geothermal power generation projects may face. Previous reports in this series quantified the life cycle freshwater requirements of geothermal power-generating systems, explored operational and environmental concerns related to the geochemical composition of geothermal fluids, and assessed future water demand by geothermal power plants according to growth projections for the industry. This report seeks to extend those analyses by including EGS flash, both as part of the life cycle analysis and water resource assessment. A regional water resource assessment based upon the life cycle results is also presented. Finally, the legal framework of water with respect to geothermal resources in the states with active geothermal development is also analyzed.

  1. Comparing Maintenance Costs of Geothermal Heat Pump Systems with other HVAC Systems in Lincoln Public Schools: Repair, Service, and Corrective Actions

    SciTech Connect

    Martin, M.A.; Durfee, D.J.; Hughes, P.J.

    1999-06-19

    The Lincoln Public School District, in Lincoln, Nebraska, recently installed vertical-bore geothermal heat pump systems in four, new, elementary schools. Because the district has consistent maintenance records and procedures, it was possible to study repair, service and corrective maintenance requests for 20 schools in the district. Each school studied provides cooling to over 70% of its total floor area and uses one of the following heating and cooling systems: vertical-bore geothermal heat pumps (GHPs), air-cooled chiller with gas-fired hot water boiler (ACUGHWB), water-cooled chiller with gas-fired hot water boiler (WCCYGHWB), or water-cooled chiller with gas-fired steam boiler (WCUGSB). Preventative maintenance and capital renewal activities were not included in the available database. GHP schools reported average total costs at 2.13 cents/ft{sup 2}-yr, followed by ACC/GHWB schools at 2.88 cents/ft{sup 2}-yr, WCC/GSB schools at 3.73 cents/ft{sup 2}-yr, and WCC/GHWB schools at 6.07 cents/ft{sup 2}-yr. Because of tax-exemptions on material purchases, a reliance on in-house labor, and the absence of preventative maintenance records in the database, these costs are lower than those reported in previous studies. A strong relationship (R{sup 2}=O.52) was found between costs examined and cooling system age: the newer the cooling equipment, the less it costs to maintain.

  2. Structural Inventory of Great Basin Geothermal Systems and Definition of Favorable Structural Settings

    DOE Data Explorer

    Faulds, James E.

    2013-12-31

    Over the course of the entire project, field visits were made to 117 geothermal systems in the Great Basin region. Major field excursions, incorporating visits to large groups of systems, were conducted in western Nevada, central Nevada, northwestern Nevada, northeastern Nevada, east‐central Nevada, eastern California, southern Oregon, and western Utah. For example, field excursions to the following areas included visits of multiple geothermal systems: - Northwestern Nevada: Baltazor Hot Spring, Blue Mountain, Bog Hot Spring, Dyke Hot Springs, Howard Hot Spring, MacFarlane Hot Spring, McGee Mountain, and Pinto Hot Springs in northwest Nevada. - North‐central to northeastern Nevada: Beowawe, Crescent Valley (Hot Springs Point), Dann Ranch (Hand‐me‐Down Hot Springs), Golconda, and Pumpernickel Valley (Tipton Hot Springs) in north‐central to northeast Nevada. - Eastern Nevada: Ash Springs, Chimney Hot Spring, Duckwater, Hiko Hot Spring, Hot Creek Butte, Iverson Spring, Moon River Hot Spring, Moorman Spring, Railroad Valley, and Williams Hot Spring in eastern Nevada. - Southwestern Nevada‐eastern California: Walley’s Hot Spring, Antelope Valley, Fales Hot Springs, Buckeye Hot Springs, Travertine Hot Springs, Teels Marsh, Rhodes Marsh, Columbus Marsh, Alum‐Silver Peak, Fish Lake Valley, Gabbs Valley, Wild Rose, Rawhide‐ Wedell Hot Springs, Alkali Hot Springs, and Baileys/Hicks/Burrell Hot Springs. - Southern Oregon: Alvord Hot Spring, Antelope Hot Spring‐Hart Mountain, Borax Lake, Crump Geyser, and Mickey Hot Spring in southern Oregon. - Western Utah: Newcastle, Veyo Hot Spring, Dixie Hot Spring, Thermo, Roosevelt, Cove Fort, Red Hill Hot Spring, Joseph Hot Spring, Hatton Hot Spring, and Abraham‐Baker Hot Springs. Structural controls of 426 geothermal systems were analyzed with literature research, air photos, google‐Earth imagery, and/or field reviews (Figures 1 and 2). Of the systems analyzed, we were able to determine the structural settings

  3. Design and Implementation of Geothermal Energy Systems at West Chester University

    SciTech Connect

    Greg Cuprak

    2011-08-31

    West Chester University is launching a comprehensive transformation of its campus heating and cooling systems from traditional fossil fuels (coal, oil and natural gas) to geothermal. This change will significantly decrease the institution's carbon footprint and serve as a national model for green campus efforts. The institution is in the process of designing and implementing this project to build well fields, a pumping station and install connecting piping to provide the geothermal heat/cooling source for campus buildings. This project addresses the US Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) goal to invest in clean energy technologies that strengthen the economy, protect the environment, and reduce dependence on foreign oil. In addition, this project advances EERE's efforts to establish geothermal energy as an economically competitive contributor to the US energy supply. For this grant, WCU will extend piping for its geo-exchange system. The work involves excavation of a trench approximately 8 feet wide and 10-12 feet deep located about 30 feet north of the curb along the north side of West Rosedale for a distance of approximately 1,300 feet. The trench will then turn north for the remaining distance (60 feet) to connect into the mechanical room in the basement of the Francis Harvey Green Library. This project will include crossing South Church Street near its intersection with West Rosedale, which will involve coordination with the Borough of West Chester. After installation of the piping, the trench will be backfilled and the surface restored to grass as it is now. Because the trench will run along a heavily-used portion of the campus, it will be accomplished in sections to minimize disruption to the campus as much as possible.

  4. Rock Mechanics and Enhanced Geothermal Systems: A DOE-sponsored Workshop to Explore Research Needs

    SciTech Connect

    Francois Heuze; Peter Smeallie; Derek Elsworth; Joel L. Renner

    2003-10-01

    This workshop on rock mechanics and enhanced geothermal systems (EGS) was held in Cambridge, Mass., on June 20-21 2003, before the Soil and Rock America 2003 International Conference at MIT. Its purpose was to bring together experts in the field of rock mechanics and geothermal systems to encourage innovative thinking, explore new ideas, and identify research needs in the areas of rock mechanics and rock engineering applied to enhanced geothermal systems. The agenda is shown in Appendix A. The workshop included experts in the fields of rock mechanics and engineering, geological engineering, geophysics, drilling, the geothermal energy production from industry, universities and government agencies, and laboratories. The list of participants is shown is Appendix B. The first day consisted of formal presentations. These are summarized in Chapter 1 of the report. By the end of the first day, two broad topic areas were defined: reservoir characterization and reservoir performance. Working groups were formed for each topic. They met and reported in plenary on the second day. The working group summaries are described in Chapter 2. The final session of the workshop was devoted to reaching consensus recommendations. These recommendations are given in Chapter 3. That objective was achieved. All the working group recommendations were considered and, in order to arrive at a practical research agenda usable by the workshop sponsors, workshop recommendations were reduced to a total of seven topics. These topics were divided in three priority groups, as follows. First-priority research topics (2): {sm_bullet} Define the pre-existing and time-dependent geometry and physical characteristics of the reservoir and its fracture network. That includes the identification of hydraulically controlling fractures. {sm_bullet} Characterize the physical and chemical processes affecting the reservoir geophysical parameters and influencing the transport properties of fractures. Incorporate those

  5. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Annual report, January-December 1983

    SciTech Connect

    Smith, K.

    1983-12-30

    Progress is reported on a project for the use of the 130/sup 0/F central Texas geothermal resource. The milestones in the construction of the system for cascading the geothermal enenrgy through two enclosed aquaculture ponds, a greenhouse heating system, and a collection catfish reservoir are reported. (MHR)

  6. Vapliq hydrothermal systems, and the vertical permeability of Los Azufres, Mexico, geothermal reservoir

    SciTech Connect

    Iglesias, Eduardo R.; Arellano, Victor M.

    1988-01-01

    We identify a new category of natural hydrothermal systems intermediate between liquid- and vapor-dominated. This category is characterized by a “vapliq” vertical pressure profile, which is nearly vaporstatic in the shallower portion of the system, and nearly boiling-point-for-depth at depth. The prototype of these systems is the geothermal field of Los Azufres, Mexico. To explore the thermohydrological conditions conducent to this type of system, we propose a 1-D vertical scenario based on generally accepted conceptual models of liquid- and vapor-dominated geothermal reservoirs. We use the corresponding mass and thermal energy transport equations to establish that a necessary condition for the existence of 2-phase hydrothermal systems is that the absolute value of the vertical thermal flux must exceed Q{sub min}, a parameter that depends only on the values of the pressure and of the thermal conductivity at the boiling point of the system. The values of Q{sub min} are typically 1-4 times the average terrestrial flux. We also find that geothermal systems in which convective heat transport is accomplished by the well-known heat-pipe mechanism can exist only if the corresponding heat flux exceeds Q{sub min} and the permeability at the boiling point of the system is smaller than k{sub Bmax}, a parameter that depends only on the values of the pressure and of the thermal conductivity at the boiling point. Typical values of k{sub Bmax} are 1-3 {times} 10{sup -18} m{sup 2}, suggesting a reason for the fact that all vapor-dominated systems are associated with very-low matrix permeability formations. Applying these insights, and the mass and heat transport equations to Los Azufres, we conclude that a contrast of 1-3 orders of magnitude exists between the vertical permeability at the boiling point and that corresponding to the vapor-dominated portion of the system. We propose that similar permeability contrasts may be responsible for the characteristic composite pressure

  7. Monitoring of Building Heating and Cooling Systems Based on Geothermal Heat Pump in Galicia (Spain)

    NASA Astrophysics Data System (ADS)

    Iglesias, M.; Rodriguez, J.; Franco, D.

    2012-10-01

    In November 2009 was signed an agreement between Galicia's Government and EnergyLab to develop a project related with the geothermal heatpumps (hereafter, GSHP) technology. That project consisted in replacing the existing thermal equipment generators (diesel boilers and air-water heat pumps) by GSHP systems in representative public buildings: two nursery schools, a university library, a health centre and a residential building. This new systems will reach the demands of existing heating, cooling and domestic hot water (hereafter, DHW). These buildings can serve as examples of energy and economic savings that can offer this technology. We will show detailed analysis of the GSHP facilities monitored, since the starting-up of them. Which includes: COP's, EER's, energy consumption, operating costs, operation hours of the system, economic and emissions comparative, geothermal exchange evolution graphs, environmental conditions evolution graphs (temperature and demands), etc. The results presented show an example of the important benefits of the GSHP technology and the significant savings that can offer its implementation for heating, cooling and DHW production. Note to the reader: The article number has been corrected on web pages on November 22, 2013.

  8. Volcanology and geothermal energy

    SciTech Connect

    Wohletz, K.; Heiken, G.

    1992-01-01

    The aim of this book is to demonstrate how volcanological concepts can be applied to the evaluation and exploration of geothermal energy resources. In regard to the geothermal content of the book, some of the information comes from the first-hand experience gained during the authors' exploration work in Middle America and with the Los Alamos Hot Dry Rock program. Other cases discussed come from classic geothermal systems in many regions and settings. The book begins with a summary of recent practical advances in volcanology, and then moves on to describe the considerable importance of pyroclastic rocks as a took to evaluate geothermal systems, including an in-depth treatment of hydrovolcanism. Following chapters deal with surface manifestations of geothermal systems, and systems associated with calderas, silicic lava domes, and basaltic volcanoes. The last chapter is on geothermal systems in maturing composite volcanoes. The Appendices include a broad overview of field methods in volcanic regions, volcanic rock classifications and properties, thermodynamic properties of water vapor (steam tables), and the use of cuttings in geothermal well logs. A two-dimensional heat flow code used for estimating geothermal resources is also given. The book makes two significant contributions: first, in its treatment of eruption dynamics, focusing on quantitative and theoretical analysis of volcanic processes, and second, in its comprehensive treatment of the fundamentals of hydrovolcanism, including fuel-coolant interactions and hydrofracturing.

  9. Geothermal direct-heat utilization assistance: Federal assistance program. Quarterly project progress report, October--December 1995

    SciTech Connect

    1996-02-01

    The report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the first quarter of FY-96. It describes 90 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment and resources. Research activities are summarized on low-temperature resource assessment, geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, development of a webpage, and progress monitor reports on geothermal resources and utilization.

  10. 1993 status report - The Bonneville Power Administration's geothermal program

    SciTech Connect

    Darr, G.D. )

    1993-01-01

    The Bonneville Power Administration's (BPA) Geothermal Program includes up to three demonstration (pilot) power projects that will initiate development of high-potential reservoirs in the Pacific Northwest. The program also includes activities that support the pilot projects and that encourage the use of the region's geothermal resources. Activities supporting the pilot projects include initiating environmental baseline monitoring programs and conducting environmental and economic impact studies. Research activities include efforts to better understand the cold water blanket phenomenon in the Cascades, a study to characterize the hydrothermal system in the Pueblo Valley, a geothermal exploration program in southeastern Oregon, and support for research to expand the use of slim-holes for resource confirmation. Efforts to address institutional issues include support for the Regional Renewables Project, which will help Northwest environmentalists become more knowledgeable about the role of conservation and renewables in the region's energy picture. A guide to geothermal permitting and licensing was prepared to help developers and utilities find their way through the regulatory maze. A geothermal curriculum is being developed for grades 4 through 8 in the Oregon schools. Data on the location and operating experience of existing U.S. geothermal plants has been collected in a database. Market penetration of geothermal heat pumps is being encouraged through a demonstration project in Montana and by helping BPA customers prepare proposals for geothermal heat pump projects that can compete successfully in BPA power acquisitions.

  11. Accelerating Geothermal Research (Fact Sheet)

    SciTech Connect

    Not Available

    2014-05-01

    Geothermal research at the National Renewable Energy Laboratory (NREL) is advancing geothermal technologies to increase renewable power production. Continuous and not dependent on weather, the geothermal resource has the potential to jump to more than 500 gigawatts in electricity production, which is equivalent to roughly half of the current U.S. capacity. Enhanced geothermal systems have a broad regional distribution in the United States, allowing the potential for development in many locations across the country.

  12. Geothermal direct-heat utilization assistance

    NASA Astrophysics Data System (ADS)

    The report summarizes activities of the Geo-Heat Center (GHC) at Oregon Institute of Technology for the first quarter of Fiscal Year 1995. It describes contacts with parties during this period related to assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, resources and equipment. Research is also being conducted on geothermal energy cost evaluation, low-temperature geothermal resource assessment, use of silica waste from the Cerro Prieto geothermal field as construction materials and geothermal heat pumps. Outreach activities include the publication of a quarterly bulletin on direct heat applications and dissemination of information on low-temperature geothermal resources and utilization.

  13. Geothermal Systems In The Snake River Plain Idaho Characterized By The Hotspot Project

    NASA Astrophysics Data System (ADS)

    Nielson, D. L.; Delahunty, C.; Shervais, J. W.

    2012-12-01

    The Snake River Plain (SRP) is potentially the largest geothermal province in the world. It is postulated that the SRP results from passage of the North American Plate over the Yellowstone mantle plume. This has resulted in felsic, caldera-related volcanism followed by voluminous eruptions of basalt. Compilations of subsurface temperature data demonstrate the masking effect of the Snake River Aquifer. As a consequence, here has been little serious geothermal exploration within the center of the plain; although there are numerous examples of low-temperature fluids, as well as the Raft River geothermal system, on the southern flanks of the SRP. Project Hotspot was designed to investigate the geothermal potential of the SRP through the coring and subsequent scientific evaluation of three holes, each representing a different geothermal environment. These are located at Kimama, north of Burley, in the center of the plain; at Kimberly near Twin Falls on the southern margin of the plain; and at Mountain Home Air Force base in the central part of the western SRP. Both the Kimberly and Mountain Home sites are located in areas that have warm wells and hot springs, whereas, the Kimama site has neither surface nor subsurface thermal manifestations. All of the sites studied here were sampled using slim hole coring techniques in conjunction with a bottom hole temperature probe developed by DOSECC. Our first hole at Kimama in the center of the eastern SRP was cored to a depth of 1,912 m. Temperature measurements showed the SRP fresh water aquifer extends to a depth of 965 m and masks the underlying high temperature gradient of 74.5oC/Km. The core hole at Kimberly reached a depth of 1,959 m and demonstrated a large low-temperature resource of >50oC below 800 m. A core hole at Mountain Home AFB in the eastern SRP reached a depth of 1,821 m and demonstrated the presence of an intermediate- to high-temperature artesian resource that has a clear magmatic association, with measured

  14. Stragegies to Detect Hidden Geothermal Systems Based on Monitoringand Analysis of CO2 in the Near-Surface Environment

    SciTech Connect

    Lewicki, Jennifer L.; Oldenburg, Curtis M.

    2005-03-29

    We investigate the potential for CO2 monitoring in thenear-surface environment as an approach to exploration for hiddengeothermal systems. Numerical simulations of CO2 migration from a modelhidden geothermal system show that CO2 concentrations can reach highlevels in the shallow subsurface even for relatively low CO2 fluxes.Therefore, subsurface measurements offer an advantage over above-groundmeasurements which are affected by winds that rapidly disperse CO2. Tomeet the challenge of detecting geothermal CO2 emissions within thenatural background variability of CO2, we propose an approach thatintegrates available detection and monitoring techniques with statisticalanalysis and modeling.

  15. Imperial County geothermal development. Quarterly report, April 1-June 30, 1982

    SciTech Connect

    Not Available

    1982-06-30

    The activities of the Geothermal Office during the quarter are discussed, including: important geothermal events, geothermal waste disposal, a grant award by the California Energy Commission, the geothermal development meeting, and the current status of geothermal development in Imperial County. Activities of the Geothermal Planner are addressed, including permits, processing of EIR's, and other planning activities. Progress on the direct heat study is reported.

  16. TOUGH2Biot - A simulator for coupled thermal-hydrodynamic-mechanical processes in subsurface flow systems: Application to CO2 geological storage and geothermal development

    NASA Astrophysics Data System (ADS)

    Lei, Hongwu; Xu, Tianfu; Jin, Guangrong

    2015-04-01

    Coupled thermal-hydrodynamic-mechanical processes have become increasingly important in studying the issues affecting subsurface flow systems, such as CO2 sequestration in deep saline aquifers and geothermal development. In this study, a mechanical module based on the extended Biot consolidation model was developed and incorporated into the well-established thermal-hydrodynamic simulator TOUGH2, resulting in an integrated numerical THM simulation program TOUGH2Biot. A finite element method was employed to discretize space for rock mechanical calculation and the Mohr-Coulomb failure criterion was used to determine if the rock undergoes shear-slip failure. Mechanics is partly coupled with the thermal-hydrodynamic processes and gives feedback to flow through stress-dependent porosity and permeability. TOUGH2Biot was verified against analytical solutions for the 1D Terzaghi consolidation and cooling-induced subsidence. TOUGH2Biot was applied to evaluate the thermal, hydrodynamic, and mechanical responses of CO2 geological sequestration at the Ordos CCS Demonstration Project, China and geothermal exploitation at the Geysers geothermal field, California. The results demonstrate that TOUGH2Biot is capable of analyzing change in pressure and temperature, displacement, stress, and potential shear-slip failure caused by large scale underground man-made activity in subsurface flow systems. TOUGH2Biot can also be easily extended for complex coupled process problems in fractured media and be conveniently updated to parallel versions on different platforms to take advantage of high-performance computing.

  17. Summary of geothermal exploration activity in the state of Washington from 1978 to 1983

    SciTech Connect

    Korosec, M.A.

    1984-01-01

    During the course of conducting the statewide reconnaissance study of Washington's potential geothermal resources, several specific areas and broader regions have been identified as targets which warrant a more concentrated effort. Over the past three years, the program has continued to identify new sites, but has concentrated on better defining the resource potential of the best areas. The locations of these geothermal areas are shown, and the level of progress for each area is shown, expressed as a percentage of completion for the various exploration tasks. Descriptions of the geothermal target areas are presented.

  18. Microbial and Chemical Characterization of Geothermal Ground Water

    NASA Astrophysics Data System (ADS)

    Schulze-Makuch, Dirk; Kennedy, John

    Subsurface geothermal sites are commonly colonized by chemolithotrophic bacteria which use rock minerals and CO_2 as sole nutrients. This type of ``life cradle'' may not only be common on Earth but may also be a likely scenario on many other planets. Three geothermal sites in southern New Mexico have been chosen to characterize geothermal waters for microbial diversity and chemical content. All sites of this on-going study are located on or near the Rio Grande Rift and are tapped into fractured reservoir systems of Paleozoic carbonate rocks, Tertiary volcanic rocks or consolidated basin-fill sediments. Geothermal fluids were analyzed for major cations and anions, selected trace elements, TOC, phosphate, fluoride and dissolved gases. The microbial analysis included phospholipid fatty acid (PLFA) analysis and DNA sequencing. Geothermal ground water was high in dissolved solids, had high concentrations of carbon dioxide and was more acidic than adjacent ground water not affected by geothermal activity. Geothermal ground-water samples contained very low amounts of biomass composed of relatively simple microbial communities. Several species of Archaebacteria were detected in some of the ground water that was derived from wells tapping into deep fractured systems. The analysis of denaturing gradient gel electrophoresis (DGGE) images indicated distinct differences of the types of microbes present in geothermal water compared to an adjacent deep non-thermal flow system.

  19. CO{sub 2} flux measurements across portions of the Dixie Valley geothermal system, Nevada

    SciTech Connect

    Bergfeld, D.; Goff, F.; Janik, C.J.; Johnson, S.D.

    1998-12-31

    A map of the CO{sub 2} flux across a newly formed area of plant kill in the NW part of the Dixie Valley geothermal system was constructed to monitor potential growth of a fumarole field. Flux measurements were recorded using a LI-COR infrared analyzer. Sample locations were restricted to areas within and near the dead zone. The data delineate two areas of high CO{sub 2} flux in different topographic settings. Older fumaroles along the Stillwater range front produce large volumes of CO{sub 2} at high temperatures. High CO{sub 2} flux values were also recorded at sites along a series of recently formed ground fractures at the base of the dead zone. The two areas are connected by a zone of partial plant kill and moderate flux on an alluvial fan. Results from this study indicate a close association between the range front fumaroles and the dead zone fractures. The goals of this study are to characterize recharge to the geothermal system, provide geochemical monitoring of reservoir fluids and to examine the temporal and spatial distribution of the CO{sub 2} flux in the dead zone. This paper reports the results of the initial CO{sub 2} flux measurements taken in October, 1997.

  20. Geochemistry and the Exploration of the Ngawha Geothermal System, New Zealand

    SciTech Connect

    Sheppard, D.S.

    1987-01-20

    The Ngawha geothermal system is atypical of New Zealand geothermal systems, being located outside the Taupo Volcanic Zone, and contained in tight sedimentary structures. Early geochemical surveys of surface discharges indicated a high gas, high borate fluid, discharging in small quantities, to the surface. An initial well (drilled in the early 1960’s, to 500m) produced a vary gassy fluid before calciting. Deeper wells drilled and discharged in the early 1980’s produced large flows of high gas fluid (up to 3wt%), at enthalpies around 1000 kj/kg. These low energy contents coupled with a low water to rock ratio, a very fractured structure, and consequent expected changes in the production fluid following exploitation, let do large scale exploitation plans being scrapped in 1982. The close attention to geochemical studies before and during the drilling operations enabled predictions of fluid type, physical conditions at depth, fluid disposal problems, and hydrologic reservoir models that have proved to be correct. The project served to indicate the value of comprehensive exploration strategies which precede the drilling phase, and the further value of, in particular, geochemical studies as an integral part of well testing procedures, for the updating of reservoir models. The close and open cooperation amongst the scientist and engineers involved was also of great value. 2 tabs., 4 figs., 15 refs.

  1. Characterization of medium enthalpy geothermal system in the Campania region (southern Italy): from geological data to resource modelling

    NASA Astrophysics Data System (ADS)

    Montegrossi, G.; Inversi, B.; Scrocca, D.; Livani, M.; Petracchini, L.

    2012-04-01

    Within the framework of the VIGOR project, a characterization of medium enthalpy geothermal resources have been carried out in the Campania region (southern Italy), with a focus on the "Guardia dei Lombardi" area (province of Avellino). The VIGOR project began on the basis of an agreement between the Ministry of Economic Development and the Italian National Research Council, and it deal with the exploitation of innovative uses of geothermal energy in the so-called "regions of convergence"(Campania, Calabria, Puglia and Sicilia). Thanks to the intense hydrocarbon exploration, carried out particularly during the 1956-1996 period, an extensive data set made up by deep wells and seismic reflection profiles exist in the study area. The previous exploration demonstrated the presence of a fractured carbonate reservoir, mainly belonging to the Cretaceous section of the Apulian shallow water carbonate platform (e.g. Scrocca 2010 and references therein), which is deformed to shape a buried antiformal stack. The culmination of the uppermost thrust unit reaches a depth of about 200 m SSL (i.e., about 1100 m below the ground level). The reservoir fluids are made up by a CO2 gas cap, which rests above an accumulation of fresh water in the central and upper part of the culmination of the deep carbonatic acquifer (e.g., Monte Forcuso 1 and 2 wells), and a saline water along the flank of the buried anticline (e.g., Bonito 1 Dir, Ciccone 1 wells). Medium enthalpy geothermal resources with a reservoir fluid temperature up to 100°C have been estimated in previous assessments at depth of 2000 m below ground level (ENEL 1987; 1994). However, the presence of thermal springs (e.g. Terme di S. Teodoro) in the area suggests the presence of an active hydraulic circuit and provide further constraints about the geochemical characteristics of the reservoir waters, and the geothermometers investigation (Duchi et al. 1995) give a possible reservoir fluid temperature up to about 124 °C. In this

  2. Real time seismic traffic light systems for hydraulic stimulations in deep geothermal systems

    NASA Astrophysics Data System (ADS)

    Wegler, Ulrich; Vasterling, Margarete; Dinske, Carsten; Becker, Jan

    2015-04-01

    In order to mitigate the risk associated with induced seismicity caused by hydraulic stimulations in deep geothermal systems so called traffic light systems (risk management plans) are used. These systems consist of a local seismic monitoring and an estimate of the current seismic hazard based on observed induced seismicity. The current hazard is compared to threshold values. Measures to reduce the seismic hazard (e.g. reducing the flow rate) specified in the risk management plan are taken, if thresholds are exceeded. Standard traffic light systems use the largest recorded magnitude or peak ground velocity to estimate current seismic hazard caused by induced earthquakes. We developed a real time technique that computes the probability of exceedance for an undesired magnitude using a statistical analysis of recorded micro-seismicity. Based on the in real time generated earthquake catalogue, we compute the magnitude of completeness, the b-value of the Gutenberg-Richter law, and the so-called seismogenic index. These three quantities are updated in real time, if more induced earthquakes are detected. Using the flow rate of the hydraulic stimulation, which we assume to be recorded in real time as well, we calculate the expected seismicity for the next hours. In particular, we compute the probability of exceedance for a predefined critical magnitude. The value is permanently updated and compared to predefined threshold values of the traffic light system. Additionally to the scenario of a continued stimulation with the current flow rate, we also consider the case of an immediate shut-in. For this scenario the probability of exceedance is computed using a modified Omori law. The developed algorithm is implemented in the real-time earthquake monitoring software SeisComP3 including a graphical user interface. So far the traffic light algorithm has only been tested in playback mode simulating a real time scenario. For example, using data of the Basel Deep Heat Mining project

  3. Enhanced Geothermal Systems (EGS) - Where Are We Now

    NASA Astrophysics Data System (ADS)

    Wyborn, D.

    2011-12-01

    There were seven major EGS projects in which reservoir circulation was achieved prior to the Geodynamics Limited project in the Innamincka granite in northern South Australia which commenced in 2002. Six other projects did not achieve significant circulation. Importantly all but one of these projects were located in granitic bodies in which it is assumed that families of existing natural fractures are present. Evidence from all these EGS projects indicated that: 1 Stimulation in granite rock resulting from water injection with no added chemicals enhanced rock fracture permeability by 2-3 orders of magnitude. 2 The increased permeability resulted from increased fracture porosity associated with slippage on existing natural fractures during the stimulation. 3The extent of the resulting reservoir could be accurately mapped by acoustic (micro-seismic) monitoring of the fracture slippages. 4 The orientation of the reservoir is strongly dependent on the relative directions of the three principle rock stress axes. 5 The stimulation pumping pressures required were 50-75% of the minimum principle stress for the depth of reservoir creation in accord with geomechanical theory, and are therefore lower than those required to open tensile fractures (fracking). 6 The size of the resulting stimulated reservoir is proportional to the volume of water injected. New space created by the increase in fracture porosity associated with the micro-seismic events is taken up by the injected water. 7 Most projects to 2002 were carried out in strike-slip and normal faulting stress regimes with minimum stress direction horizontal and the resulting reservoirs were oriented close to vertically. 8 Volcanic activity can only occur in strike-slip and normal faulting stress regimes so EGS reservoirs in volcanic areas will be oriented close to vertically. 9 The Fjallbacka project in Sweden was the only project carried out in an overthrust stress regime (minimum stress direction vertical) and the

  4. Geothermal Program Review XI: proceedings. Geothermal Energy - The Environmental Responsible Energy Technology for the Nineties

    SciTech Connect

    Not Available

    1993-10-01

    These proceedings contain papers pertaining to current research and development of geothermal energy in the USA. The seven sections of the document are: Overview, The Geysers, Exploration and Reservoir Characterization, Drilling, Energy Conversion, Advanced Systems, and Potpourri. The Overview presents current DOE energy policy and industry perspectives. Reservoir studies, injection, and seismic monitoring are reported for the geysers geothermal field. Aspects of geology, geochemistry and models of geothermal exploration are described. The Drilling section contains information on lost circulation, memory logging tools, and slim-hole drilling. Topics considered in energy conversion are efforts at NREL, condensation on turbines and geothermal materials. Advanced Systems include hot dry rock studies and Fenton Hill flow testing. The Potpourri section concludes the proceedings with reports on low-temperature resources, market analysis, brines, waste treatment biotechnology, and Bonneville Power Administration activities. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

  5. Volcanology and volcanic activity with a primary focus on potential hazard impacts for the Hawaii geothermal project

    SciTech Connect

    Moore, R.B.; Delaney, P.T.; Kauahikaua, J.P.

    1993-10-01

    This annotated bibliography reviews published references about potential volcanic hazards on the Island of Hawaii that are pertinent to drilling and operating geothermal wells. The first two sections of this annotated bibliography list the most important publications that describe eruptions of Kilauea volcano, with special emphasis on activity in and near the designated geothermal subzones. References about historic eruptions from Mauna Loa`s northeast rift zone, as well as the most recent activity on the southern flank of dormant Mauna Kea, adjacent to the Humu`ula Saddle are described. The last section of this annotated bibliography lists the most important publications that describe and analyze deformations of the surface of Kilauea and Mauna Loa volcanoes.

  6. The impact of temperature on microbial diversity and AOA activity in the Tengchong Geothermal Field, China

    PubMed Central

    Li, Haizhou; Yang, Qunhui; Li, Jian; Gao, Hang; Li, Ping; Zhou, Huaiyang

    2015-01-01

    Using a culture-independent method that combines CARD-FISH, qPCR and 16S rDNA, we investigated the abundance, community structure and diversity of microbes along a steep thermal gradient (50–90 °C) in the Tengchong Geothermal Field. We found that Bacteria and Archaea abundance changed markedly with temperature changes and that the number of cells was lowest at high temperatures (90.8 °C). Under low-temperature conditions (52.3–74.6 °C), the microbial communities were dominated by Bacteria, which accounted for 60–80% of the total number of cells. At 74.6 °C, Archaea were dominant, and at 90.8 °C, they accounted for more than 90% of the total number of cells. Additionally, the microbial communities at high temperatures (74.6–90.8 °C) were substantially simpler than those at the low-temperature sites. Only a few genera (e.g., bacterial Caldisericum, Thermotoga and Thermoanaerobacter, archaeal Vulcanisaeta and Hyperthermus) often dominated in high-temperature environments. Additionally, a positive correlation between Ammonia-Oxidizing Archaea (AOA) activity and temperature was detected. AOA activity increased from 17 to 52 pmol of NO2− per cell d−1 with a temperature change from 50 to 70 °C. PMID:26608685

  7. The impact of temperature on microbial diversity and AOA activity in the Tengchong Geothermal Field, China

    NASA Astrophysics Data System (ADS)

    Li, Haizhou; Yang, Qunhui; Li, Jian; Gao, Hang; Li, Ping; Zhou, Huaiyang

    2015-11-01

    Using a culture-independent method that combines CARD-FISH, qPCR and 16S rDNA, we investigated the abundance, community structure and diversity of microbes along a steep thermal gradient (50-90 °C) in the Tengchong Geothermal Field. We found that Bacteria and Archaea abundance changed markedly with temperature changes and that the number of cells was lowest at high temperatures (90.8 °C). Under low-temperature conditions (52.3-74.6 °C), the microbial communities were dominated by Bacteria, which accounted for 60-80% of the total number of cells. At 74.6 °C, Archaea were dominant, and at 90.8 °C, they accounted for more than 90% of the total number of cells. Additionally, the microbial communities at high temperatures (74.6-90.8 °C) were substantially simpler than those at the low-temperature sites. Only a few genera (e.g., bacterial Caldisericum, Thermotoga and Thermoanaerobacter, archaeal Vulcanisaeta and Hyperthermus) often dominated in high-temperature environments. Additionally, a positive correlation between Ammonia-Oxidizing Archaea (AOA) activity and temperature was detected. AOA activity increased from 17 to 52 pmol of NO2- per cell d-1 with a temperature change from 50 to 70 °C.

  8. Geothermal direct-heat utilization assistance. Quarterly report, January - March 1997

    SciTech Connect

    Lienau, P.

    1997-04-01

    This report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the second quarter of FY-97. It describes 176 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics and resources. Research activities are summarized on well pumping in commercial groundwater heat pump systems. A memorandum of understanding between the GHC and EIA is described. Work accomplishments on the Guidebook are discussed. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  9. Three-Dimensional Geothermal Fairway Mapping: Examples From the Western Great Basin, USA

    SciTech Connect

    Siler, Drew L; Faulds, James E

    2013-09-29

    Elevated permeability along fault systems provides pathways for circulation of geothermal fluids. Accurate location of such fluid flow pathways in the subsurface is crucial to future geothermal development in order to both accurately assess resource potential and mitigate drilling costs by increasing drilling success rates. Employing a variety of surface and subsurface data sets, we present detailed 3D geologic analyses of two Great Basin geothermal systems, the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, Nevada. 3D modeling provides the framework for quantitative structural analyses. We combine 3D slip and dilation tendency analysis along fault zones and calculations of fault intersection density in the two geothermal systems with the locations of lithologies capable of supporting dense, interconnected fracture networks. The collocation of these permeability promoting characteristics with elevated heat represent geothermal ‘fairways’, areas with ideal conditions for geothermal fluid flow. Location of geothermal fairways at high resolution in 3D space can help to mitigate the costs of geothermal exploration by providing discrete drilling targets and data-based evaluations of reservoir potential.

  10. Using Electromagnetic Techniques to Test Models for Shallow Permeability in the Surprise Valley, CA Geothermal System

    NASA Astrophysics Data System (ADS)

    Hawkes, S.; McClain, J. S.; Kahn, A.; Lewis, K.

    2013-12-01

    Surprise Valley in northeastern Modoc County, CA is the westernmost major extensional graben in the northwestern Basin and Range province. There are abundant faults coincident with moderate to boiling temperature hot springs that discharge along the western rim of the valley and in the central eastern part of the valley. Fluid recharge and discharge pathways are poorly understood despite sporadic geothermal exploration, drilling, and development since the 1950's and a wide variety of academic studies that have been focused in the region. It is hypothesized that thermal fluids discharged into the basin exploit fracture permeability related to active extensional faulting along the Surprise Valley Fault (SVF), Lake City Fault Zone (LCFZ), and faults in the Hays Canyon Range (HCR). We present several fault-perpendicular Magnetotelluric profiles conducted across the LCFZ and HCR faults with the goal of imaging the orientation and extent of the geothermal reservoir that supplies the hot springs. Initial results are consistent with the HCR faults tapping a deep conductive aquifer below shallow resistive extrusive igneous rocks, with narrow low resistivity regions beneath the faults. There is no conclusive evidence for or against the LCFZ acting as a preferred fluid pathway, due to relatively homogeneous distribution highly conductive materials and the difficulty in differentiating clay-rich lacustrine sediments from hydrothermal fluids or clays.

  11. Microbiological Monitoring in Geothermal Plants

    NASA Astrophysics Data System (ADS)

    Alawi, M.; Lerm, S.; Linder, R.; Vetter, A.; Vieth-Hillebrand, A.; Miethling-Graff, R.; Seibt, A.; Wolfgramm, M.; Wuerdemann, H.

    2010-12-01

    examined precipitation products like iron sulfides are indicating that microorganisms play an important role for the understanding of processes in engineered geothermal systems. The further identification of crucial process parameters influencing microbial activities will help to develop appropriate counter measures against microbial induced clogging and corrosion.

  12. Development of Active Seismic Vector-Wavefield Imaging Technology for Geothermal Applications

    SciTech Connect

    B. A. Hardage; J. L. Simmons, Jr.; M. DeAngelo

    1999-10-01

    This report describes the development and testing of vector-wavefield seismic sources that can generate shear (S) waves that may be valuable in geothermal exploration and reservoir characterization. Also described is a 3-D seismic data-processing effort to create images of Rye Patch geothermal reservoir from 3-D sign-bit data recorded over the geothermal prospect. Two seismic sources were developed and tested in this study that can be used to illuminate geothermal reservoirs with S-waves. The first was an explosive package that generates a strong, azimuth-oriented, horizontal force vector when deployed in a conventional shot hole. This vector-explosive source has never been available to industry before. The second source was a dipole formed by operating two vertical vibrators in either a force or phase imbalance. Field data are shown that document the strong S-wave modes generated by these sources.

  13. Play-fairway analysis for geothermal exploration: Examples from the Great Basin, western USA

    SciTech Connect

    Siler, Drew L; Faulds, James E

    2013-10-27

    Elevated permeability within fault systems provides pathways for circulation of geothermal fluids. Future geothermal development depends on precise and accurate location of such fluid flow pathways in order to both accurately assess geothermal resource potential and increase drilling success rates. The collocation of geologic characteristics that promote permeability in a given geothermal system define the geothermal ‘fairway’, the location(s) where upflow zones are probable and where exploration efforts including drilling should be focused. We define the geothermal fairway as the collocation of 1) fault zones that are ideally oriented for slip or dilation under ambient stress conditions, 2) areas with a high spatial density of fault intersections, and 3) lithologies capable of supporting dense interconnected fracture networks. Areas in which these characteristics are concomitant with both elevated temperature and fluids are probable upflow zones where economic-scale, sustainable temperatures and flow rates are most likely to occur. Employing a variety of surface and subsurface data sets, we test this ‘play-fairway’ exploration methodology on two Great Basin geothermal systems, the actively producing Brady’s geothermal system and a ‘greenfield’ geothermal prospect at Astor Pass, NV. These analyses, based on 3D structural and stratigraphic framework models, reveal subsurface characteristics about each system, well beyond the scope of standard exploration methods. At Brady’s, the geothermal fairways we define correlate well with successful production wells and pinpoint several drilling targets for maintaining or expanding production in the field. In addition, hot-dry wells within the Brady’s geothermal field lie outside our defined geothermal fairways. At Astor Pass, our play-fairway analysis provides for a data-based conceptual model of fluid flow within the geothermal system and indicates several targets for exploration drilling.

  14. Structural control on geothermal circulation in the Tocomar geothermal volcanic area (Puna plateau, Argentina)

    NASA Astrophysics Data System (ADS)

    Giordano, Guido

    2016-04-01

    The reconstruction of the stratigraphical-structural framework and the hydrogeology of geothermal areas is fundamental for understanding the relationships between cap rocks, reservoir and circulation of geothermal fluids and for planning the exploitation of the field. The Tocomar geothermal volcanic area (Puna plateau, Central Andes, NW Argentina) has a high geothermal potential. It is crossed by the active NW-SE trans-Andean tectonic lineament known as the Calama-Olacapato-Toro (COT) fault system, which favours a high secondary permeability testified by the presence of numerous thermal springs. This study presents new stratigraphic, structural, volcanological, geochemical and hydrogeological data on the geothermal field. Our data suggest that the main geothermal reservoir is located within or below the Pre-Palaeozoic-Ordovician basement units, characterised by unevenly distributed secondary permeability. The reservoir is recharged by infiltration in the ridges above 4500 m a.s.l., where basement rocks are in outcrop. Below 4500 m a.s.l., the reservoir is covered by the low permeable Miocene-Quaternary units that allow a poor circulation of shallow groundwater. Geothermal fluids upwell in areas with more intense fracturing, especially where main regional structures, particularly NW-SE COT-parallel lineaments, intersect with secondary structures, such as at the Tocomar field.

  15. Geothermal pipeline - progress and development update, geothermal progress monitor

    SciTech Connect

    1996-08-01

    This document is a progress and development update and geothermal progress monitor prepared by the Geo-Heat Center at the Oregon Institute of Technology in Klamath Falls, Oregon. Several upcoming meetings in the field of geothermal energy and resource development are announced. Proposed and past geothermal activities within the Glass Mountain Known Geothermal Resource Area are also discussed. As of this date, there has been limited geothermal exploration in this area, however, two projects located in the near vicinity have been proposed within the last two years.

  16. Geothermal pipeline

    SciTech Connect

    1997-08-01

    The Geothermal Pipeline is a progress and development update from the Geothermal Progress Monitor and includes brief descriptions of various geothermal projects around the world. The following topics are covered: The retirement of Geo-Heat Center Director Paul Lienau, announcement of two upcoming geothermal meetings, and a proposed geothermal power plant project in the Medicine Lake/Glass Mountain area of California. Also included is an article about the Bonneville Power Administration`s settlements with two California companies who had agreed to build geothermal power plants on the federal agency`s behalf, geothermal space heating projects and use of geothermal energy for raising red crayfish in Oregon, and some updates on geothermal projects in Minnesota, Pennsylvania, and China.

  17. Imperial County geothermal development quarterly report, July 1-September 30, 1983

    SciTech Connect

    Not Available

    1983-10-01

    The highlights of geothermal development in Imperial County during July, August, and September 1983 are discussed. Topics include the status of geothermal development projects in the county, geothermal staff activities and research projects, and other geothermal-related topics.

  18. Report on design, construction, and testing of CO/sub 2/ breakout system for geothermal brines

    SciTech Connect

    Robertus, R.J.; Shannon, D.W.; Sullivan, R.G.

    1984-03-01

    A skid mounted test facility has been built for determining conditions at which CO/sub 2/ flashes from geothermal brines. The system has been checked and operated at one geothermal plant. It performed as designed. The equipment is designed to operate at temperatures and pressures typical of wells near Heber, California. (Nominally 180/sup 0/C and 300 to 500 psig). It has heat exchangers which can cool the brine to less than 70/sup 0/C. (The cooling water is recirculated after being cooled by a forced air heat exchanger). Breakout pressures can be determined for any temperature between 70/sup 0/C and wellhead temperature. An adjustable orifice provides final control on pressure required to initiate flashing. The orifice is at the bottom of a sight glass. A light beam shines through the sight glass and focuses on a photoelectric cell. The presence of bubbles scatters light and decreases the output of the cell. Results using the cell were more reproducible than those using the naked eye. Results from one test show a smooth curve over the temperature range 75/sup 0/C to 165/sup 0/C. Agreement between the experimental values and calculated ones is discussed.

  19. The effect of CO{sub 2} on reservoir behavior for geothermal systems

    SciTech Connect

    Gaulke, S.W.

    1986-12-01

    The purpose was to gain an understanding of the effects of non-condensible gases (CO/sub 2/) in fractured two-phase geothermal systems. A thorough review of previous work on non-condensible gases was carried out. In addition, since the flowing mass fraction of CO/sub 2/ is strongly controlled by the flowing saturation, the flowing enthalpy literature was also reviewed. Numerical techniques were employed to examine how non-condensible gases (CO/sub 2/) affect well transients and to determine the value of these effects as tools to evaluate in situ reservoir parameters. Simplified reservoir models were used to define the effects of CO/sub 2/ in the reservoir and the resulting transient behavior at the feedzones to the well. Furthermore, fracture-matrix interaction was studied in detail to identify the effects of CO/sub 2/ on recovery and flow patterns within the reservoir. The insight gained from the sensitivity studies for enthalpy and CO/sub 2/ transients was applied to interpret transient data from well BR21 at the Broadlands geothermal field of New Zealand.

  20. Modeling the Impact of Multiple Physical Processes on the Stimulation and Longevity of Enhanced Geothermal Systems

    NASA Astrophysics Data System (ADS)

    Taron, J.; Williams, C. F.; Hickman, S. H.; Ingebritsen, S.

    2014-12-01

    The evolution of enhanced geothermal systems (EGS) entails spatially and temporally evolving permeability fields. During non-isothermal fluid injection, thermo-elastic stress and fluid pressure changes act upon partially open or hydrothermally altered fracture sets to enhance formation permeability. The physical couplings that drive this behavior are non-linearly dependent upon one another to varying degrees. To explore these interactions we are developing a thermo-hydromechanical (THM) simulator capable of coupling the dominant physics of shear stimulation and allowing flexibility in the use of monolithic or staggered numerical schemes. Permeability is allowed to evolve under several constitutive models tailored to both porous media and fractures, considering the influence of thermo-hydromechanical stress, creep, and elasto-plastic shear and dilation in a ubiquitously fractured medium. From this basis we explore the coupled physical processes that control the evolution of permeability during shear stimulation and long-term evolution of a geothermal reservoir. Previous attempts to model the stimulation and sustainability of EGS are discussed in their relation to the current work and in an attempt to elucidate the dominant mechanisms of permeability alteration, including order-of-magnitude differences in permeability gain during hydraulic stimulation in isothermal versus non-isothermal simulations.

  1. Probabilistic 3-D time-lapse inversion of magnetotelluric data: application to an enhanced geothermal system

    NASA Astrophysics Data System (ADS)

    Rosas-Carbajal, M.; Linde, N.; Peacock, J.; Zyserman, F. I.; Kalscheuer, T.; Thiel, S.

    2015-12-01

    Surface-based monitoring of mass transfer caused by injections and extractions in deep boreholes is crucial to maximize oil, gas and geothermal production. Inductive electromagnetic methods, such as magnetotellurics, are appealing for these applications due to their large penetration depths and sensitivity to changes in fluid conductivity and fracture connectivity. In this work, we propose a 3-D Markov chain Monte Carlo inversion of time-lapse magnetotelluric data to image mass transfer following a saline fluid injection. The inversion estimates the posterior probability density function of the resulting plume, and thereby quantifies model uncertainty. To decrease computation times, we base the parametrization on a reduced Legendre moment decomposition of the plume. A synthetic test shows that our methodology is effective when the electrical resistivity structure prior to the injection is well known. The centre of mass and spread of the plume are well retrieved. We then apply our inversion strategy to an injection experiment in an enhanced geothermal system at Paralana, South Australia, and compare it to a 3-D deterministic time-lapse inversion. The latter retrieves resistivity changes that are more shallow than the actual injection interval, whereas the probabilistic inversion retrieves plumes that are located at the correct depths and oriented in a preferential north-south direction. To explain the time-lapse data, the inversion requires unrealistically large resistivity changes with respect to the base model. We suggest that this is partly explained by unaccounted subsurface heterogeneities in the base model from which time-lapse changes are inferred.

  2. Thermo-Hydro-Mechanical-Chemical Coupled Modeling of Geothermal Doublet Systems in Limestones

    NASA Astrophysics Data System (ADS)

    Rühaak, Wolfram; Pei, Liang; Heldmann, Claus-Dieter; Bartels, Jörn; Sass, Ingo

    2015-04-01

    Limestone aquifers in Southern Germany have been used within the last decade very successfully for geothermal heating and - to a lesser extent - for power generation. As an example the region around Munich has been extensively explored. While the extent of usage of this reservoir is increasing there is also an increased interest in better understanding of the reservoir properties and its change in the course of operation. For instance, the observed production and injection pressures are partly hard to explain. They may be related to mechanical or chemical processes, or both. Based on extensive data of outcrop studies and drillings, a data-base for the relevant physical properties of the respective limestones has been complied. The data include thermal conductivity, density, specific heat capacity, permeability, as well as mechanical properties like thermal expansion coefficient and elasticity modules. By using the hydro-thermo-chemical simulator FEFLOW together with an extension for thermo- and hydro-mechanical coupling the relevant processes are studied and compared with observed data. Conclusions for an optimized operation of geothermal systems in limestones are given and discussed.

  3. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Annual report, January-December 1982

    SciTech Connect

    Smith, K.

    1982-12-31

    Progress is reported on a project for the use of the 130/sup 0/F central Texas geothermal resource. The revised project consists of cascading the geothermal energy through two enclosed aquaculture ponds, a greenhouse heating system, and into a collection catfish reservoir. (MHR)

  4. Rock specific hydraulic fracturing and matrix acidizing to enhance a geothermal system — Concepts and field results

    NASA Astrophysics Data System (ADS)

    Zimmermann, Günter; Blöcher, Guido; Reinicke, Andreas; Brandt, Wulf

    2011-04-01

    Enhanced geothermal systems (EGS) are engineered reservoirs developed to extract economic amounts of heat from low permeability and/or porosity geothermal resources. To enhance the productivity of reservoirs, a site specific concept is necessary to actively make reservoir conditions profitable using specially adjusted stimulation treatments, such as multi fracture concepts and site specific well path design. The results of previously performed stimulation treatments in the geothermal research well GtGrSk4/05 at Groß Schönebeck, Germany are presented. The reservoir is located at a 4100-4300 m depth within the Lower Permian of the NE German Basin with a bottom-hole temperature of 150 °C. The reservoir rock is classified by two lithological units from bottom to top: volcanic rocks (andesitic rocks) and siliciclastics ranging from conglomerates to fine-grained sandstones (fluvial sediments). The stimulation treatments included multiple hydraulic stimulations and an acid treatment. In order to initiate a cross-flow from the sandstone layer, the hydraulic stimulations were performed in different depth sections (two in the sandstone section and one in the underlying volcanic section). In low permeability volcanic rocks, a cyclic hydraulic fracturing treatment was performed over 6 days in conjunction with adding quartz in low concentrations to maintain a sustainable fracture performance. Flow rates of up to 150 l/s were realized, and a total of 13,170 m 3 of water was injected. A hydraulic connection to the sandstone layer was successfully achieved in this way. However, monitoring of the water level in the offsetting well EGrSk3/90, which is 475 m apart at the final depth, showed a very rapid water level increase due to the stimulation treatment. This can be explained by a connected fault zone within the volcanic rocks. Two gel-proppant treatments were performed in the slightly higher permeability sandstones to obtain long-term access to the reservoir rocks. During each

  5. Interactive Maps from the Great Basin Center for Geothermal Energy

    DOE Data Explorer

    The Great Basin Center for Geothermal Energy, part of the University of Nevada, Reno, conducts research towards the establishment of geothermal energy as an economically viable energy source within the Great Basin. The Center specializes in collecting and synthesizing geologic, geochemical, geodetic, geophysical, and tectonic data, and using Geographic Information System (GIS) technology to view and analyze this data and to produce favorability maps of geothermal potential. The interactive maps are built with layers of spatial data that are also available as direct file downloads (see DDE00299). The maps allow analysis of these many layers, with various data sets turned on or off, for determining potential areas that would be favorable for geothermal drilling or other activity. They provide information on current exploration projects and leases, Bureau of Land Management land status, and map presentation of each type of scientific spatial data: geothermal, geophysical, geologic, geodetic, groundwater, and geochemical.

  6. Comparing FRACHEM and TOUGHREACT for reactive transport modelingof brine-rock interactions in enhanced geothermal systems (EGS)

    SciTech Connect

    Andre, L.; Spycher, N.; Xu, T.; Pruess, K.; Vuataz, F.-D.

    2005-11-15

    Coupled modelling of fluid flow and reactive transport ingeothermal systems is challenging because of reservoir conditions such ashigh temperatures, elevated pressures and sometimes high salinities ofthe formation fluids. Thermal hydrological-chemical (THC) codes, such asFRACHEM and TOUGHREACT, have been developed to evaluate the long-termhydrothermal and chemical evolution of exploited reservoirs. In thisstudy, the two codes were applied to model the same geothermal reservoir,to forecast reservoir evolution using respective thermodynamic andkinetic input data. A recent (unreleased) TOUGHREACT version allows theuse of either an extended Debye-Hu?ckel or Pitzer activity model forcalculating activity coefficients, while FRACHEM was designed to use thePitzer formalism. Comparison of models results indicate that differencesin thermodynamic equilibrium constants, activity coefficients andkinetics models can result in significant differences in predictedmineral precipitation behaviour and reservoir-porosity evolution.Differences in the calculation schemes typically produce less differencein model outputs than differences in input thermodynamic and kineticdata, with model results being particularly sensitive to differences inion-interaction parameters for highsalinity systems.

  7. Application of 2D VSP Imaging Technology to the Targeting of Exploration and Production Wells in a Basin and Range Geothermal System

    SciTech Connect

    Ellis, Richard K.

    2013-01-01

    The Humboldt House-Rye Patch geothermal resource area (HH-RP) comprises approximately 12,000 acres along and west of the Humboldt Range, adjacent to the Rye Patch Reservoir (Figure 1). A Federal Geothermal Unit covers essentially all of the known shallow thermal anomaly at the site, and the Operator, Presco Energy, is in the process of completing wellfield development adjacent to the Rye Patch binary plant, a nominal 17-megawatt system in the southern Unit area (Figure 1). DOE award EE0002840, made under the auspices of the Geothermal Technologies Program, was originally approved in January of 2010, and used a VSP profiling technology to improve seismic imaging in the Basin and Range. Phase I field activities were conducted in the 3rd quarter of 2010, and both the Phase I report and a supplemental report were completed in March and April of 2011. Two targets were identified for tests of upflow structures, both using existing wellbores, originally the 51-21 and 52-28, in the Rye Patch wellfield. The Phase II validation was approved by DOE in May of 2011.

  8. Potential impacts of artificial intelligence expert systems on geothermal well drilling costs:

    SciTech Connect

    Satrape, J.V.

    1987-11-24

    The Geothermal research Program of the US Department of Energy (DOE) has as one of its goals to reduce the cost of drilling geothermal wells by 25 percent. To attain this goal, DOE continuously evaluates new technologies to determine their potential in contributing to the Program. One such technology is artifical intelligence (AI), a branch of computer science that, in recent years, has begun to impact the marketplace in a number of fields. Expert systems techniques can (and in some cases, already have) been applied to develop computer-based ''advisors'' to assist drilling personnel in areas such as designing mud systems, casing plans, and cement programs, optimizing drill bit selection and bottom hole asssembly (BHA) design, and alleviating lost circulation, stuck pipe, fishing, and cement problems. Intelligent machines with sensor and/or robotic directly linked to AI systems, have potential applications in areas of bit control, rig hydraulics, pipe handling, and pipe inspection. Using a well costing spreadsheet, the potential savings that could be attributed to each of these systems was calculated for three base cases: a dry steam well at The Geysers, a medium-depth Imerial Valley well, and a deep Imperial Valley well. Based on the average potential savings to be realized, expert systems for handling lost circulations problems and for BHA design are the most likely to produce significant results. Automated bit control and rig hydraulics also exhibit high potential savings, but these savings are extremely sensitive to the assumptions of improved drilling efficiency and the cost of these sytems at the rig. 50 refs., 19 figs., 17 tabs.

  9. Delineation of the High Enthalpy Reservoirs of the Sierra Nevada Volcanic Geothermal System, South-Central Chile

    NASA Astrophysics Data System (ADS)

    Alam, M.; Muñoz, M.; Parada, M.

    2011-12-01

    Geothermal system associated with the Pleistocene-Holocene Sierra Nevada volcano (SNVGS) in the Araucanía Region of Chile has surface manifestations from the north-western flank of the volcano, up to Manzanar and Malalcahuello. Baños del Toro, located on the northwestern flank of the volcano, has numerous fumaroles and acid pools (acid sulfate waters, T=~90°C, pH=2.1, TDS=3080 mg/L); while Aguas de la Vaca, near the base of the volcano, has a bubbling spring (chloride-sulfate waters, T=~60°C, pH=7.0, TDS=950 mg/L). Five shallow (<120m) wells (2 at Manzanar and 3 at Malalcahuello) dug and drilled in the Cautín River Valley discharge alkaline (pH= 9-10) waters with relatively low TDS (130-210mg/L). The main heat source of the geothermal system is apparently the magmatic system of the Sierra Nevada volcano. Liquiñe-Ofqui Fault Zone (LOFZ) that transects the area forms excellent conduits for the flow of the geothermal waters. The geothermal reservoirs are hosted in the volcanic rocks interceded with glacial deposits over the North Patagonian Batholith that forms an impermeable barrier, and thus constitutes the lower boundary of the geothermal system and also controls the lateral flow of the fluids. An equilibrium temperature of ~210°C is derived from gas geothermometry (CO2/Ar-H2/Ar) of the discharges at Baños del Toro. Geothermal fluids from the upflow area on the northwestern flank of the volcano migrate northwards to the Cautín River Valley. The geothermal system has a high enthalpy reservoir(s) on the northwestern flank of the Sierra Nevada volcano and low-enthalpy reservoirs in the Cautín River Valley that have been tapped to form spas at Manzanar and Malalcahuello. While sub-vertical fractures of LOFZ facilitate the recharge of the system, lateral flow of the geothermal fluids is apparently controlled by lithology; Melipueclo Pluton in particular prevents the westward flow from the upflow zone, causing the flow only northwards to Malalcahuello and

  10. Technical support for geopressured-geothermal well activities in Louisiana. Final report, September 27, 1978-December 31, 1980

    SciTech Connect

    Wrighton, F.M.; Bebout, D.; Carver, D.R.; Groat, C.C.; Johnson, A.E. Jr.

    1981-08-31

    The data analysis is based on the Brazoria Texas well and the balance of the modeling work is theoretical. Progress in the regional assessment of the geopressured-geothermal resource in Louisiana is reported. Environmental monitoring effort established monitoring systems and baseline environmental measurements. Efforts to improve the technoeconomic model, improve the estimates of methane in solution, and to evaluate newly identified sites are described. (MHR)

  11. Active Management of Integrated Geothermal-CO2 Storage Reservoirs in Sedimentary Formations

    DOE Data Explorer

    Buscheck, Thomas A.

    2012-01-01

    Active Management of Integrated Geothermal–CO2 Storage Reservoirs in Sedimentary Formations: An Approach to Improve Energy Recovery and Mitigate Risk : FY1 Final Report The purpose of phase 1 is to determine the feasibility of integrating geologic CO2 storage (GCS) with geothermal energy production. Phase 1 includes reservoir analyses to determine injector/producer well schemes that balance the generation of economically useful flow rates at the producers with the need to manage reservoir overpressure to reduce the risks associated with overpressure, such as induced seismicity and CO2 leakage to overlying aquifers. This submittal contains input and output files of the reservoir model analyses. A reservoir-model "index-html" file was sent in a previous submittal to organize the reservoir-model input and output files according to sections of the FY1 Final Report to which they pertain. The recipient should save the file: Reservoir-models-inputs-outputs-index.html in the same directory that the files: Section2.1.*.tar.gz files are saved in.

  12. Active Management of Integrated Geothermal-CO2 Storage Reservoirs in Sedimentary Formations

    DOE Data Explorer

    Buscheck, Thomas A.

    2000-01-01

    Active Management of Integrated Geothermal–CO2 Storage Reservoirs in Sedimentary Formations: An Approach to Improve Energy Recovery and Mitigate Risk: FY1 Final Report The purpose of phase 1 is to determine the feasibility of integrating geologic CO2 storage (GCS) with geothermal energy production. Phase 1 includes reservoir analyses to determine injector/producer well schemes that balance the generation of economically useful flow rates at the producers with the need to manage reservoir overpressure to reduce the risks associated with overpressure, such as induced seismicity and CO2 leakage to overlying aquifers. This submittal contains input and output files of the reservoir model analyses. A reservoir-model "index-html" file was sent in a previous submittal to organize the reservoir-model input and output files according to sections of the FY1 Final Report to which they pertain. The recipient should save the file: Reservoir-models-inputs-outputs-index.html in the same directory that the files: Section2.1.*.tar.gz files are saved in.

  13. Enhanced Geothermal Systems Research and Development: Models of Subsurface Chemical Processes Affecting Fluid Flow

    SciTech Connect

    Moller, Nancy; Weare J. H.

    2008-05-29

    Successful exploitation of the vast amount of heat stored beneath the earth’s surface in hydrothermal and fluid-limited, low permeability geothermal resources would greatly expand the Nation’s domestic energy inventory and thereby promote a more secure energy supply, a stronger economy and a cleaner environment. However, a major factor limiting the expanded development of current hydrothermal resources as well as the production of enhanced geothermal systems (EGS) is insufficient knowledge about the chemical processes controlling subsurface fluid flow. With funding from past grants from the DOE geothermal program and other agencies, we successfully developed advanced equation of state (EOS) and simulation technologies that accurately describe the chemistry of geothermal reservoirs and energy production processes via their free energies for wide XTP ranges. Using the specific interaction equations of Pitzer, we showed that our TEQUIL chemical models can correctly simulate behavior (e.g., mineral scaling and saturation ratios, gas break out, brine mixing effects, down hole temperatures and fluid chemical composition, spent brine incompatibilities) within the compositional range (Na-K-Ca-Cl-SO4-CO3-H2O-SiO2-CO2(g)) and temperature range (T < 350°C) associated with many current geothermal energy production sites that produce brines with temperatures below the critical point of water. The goal of research carried out under DOE grant DE-FG36-04GO14300 (10/1/2004-12/31/2007) was to expand the compositional range of our Pitzer-based TEQUIL fluid/rock interaction models to include the important aluminum and silica interactions (T < 350°C). Aluminum is the third most abundant element in the earth’s crust; and, as a constituent of aluminosilicate minerals, it is found in two thirds of the minerals in the earth’s crust. The ability to accurately characterize effects of temperature, fluid mixing and interactions between major rock-forming minerals and hydrothermal and

  14. Geothermal Energy Retrofit

    SciTech Connect

    Bachman, Gary

    2015-07-28

    The Cleary University Geothermal Energy Retrofit project involved: 1. A thermal conductivity test; 2. Assessment of alternative horizontal and vertical ground heat exchanger options; 3. System design; 4. Asphalt was stripped from adjacent parking areas and a vertical geothermal ground heat exchanger system installed; 5. the ground heat exchanger was connected to building; 6. a system including 18 heat pumps, control systems, a manifold and pumps, piping for fluid transfer and ductwork for conditioned air were installed throughout the building.

  15. Evolution of the thermal cap in two wells from the Salton Sea geothermal system, California

    SciTech Connect

    Moore, Joseph N.; Adams, Michael C.

    1988-01-01

    The Salton Sea geothermal system is overlain by a thermal cap of low permeability rocks that restricts the upward movement of the high-temperature reservoir brines. Petrographic and fluid inclusion data from two wells show that the thermal cap in the southern part of the field consists of an upper layer of lacustrine and evaporite deposits with low initial permeabilities and a lower layer of deltaic sandstones. The sandstones were incorporated into the thermal cap as downward percolating fluids deposited anhydrite and calcite in the pore space of the rocks, reducing their permeabilities. During development of the thermal cap, base-metal sulfides, potassium feldspar and quartz veins were deposited by brines from higher temperature portions of the system.

  16. Michrohole Arrays Drilled with Advanced Abrasive Slurry Jet Technology to Efficiently Exploit Enhanced Geothermal Systems

    SciTech Connect

    Oglesby, Kenneth; Finsterle, Stefan; Zhang, Yingqi; Pan, Lehua; Dobson, Parick; Mohan, Ram; Shoham, Ovadia; Felber, Betty; Rychel, Dwight

    2014-03-12

    This project had two major areas of research for Engineered/ Enhanced Geothermal System (EGS) development - 1) study the potential benefits from using microholes (i.e., bores with diameters less than 10.16 centimeters/ 4 inches) and 2) study FLASH ASJ to drill/ install those microbores between a well and a fracture system. This included the methods and benefits of drilling vertical microholes for exploring the EGS reservoir and for installing multiple (forming an array of) laterals/ directional microholes for creating the in-reservoir heat exchange flow paths. Significant benefit was found in utilizing small microbore sized connecting bores for EGS efficiency and project life. FLASH ASJ was deemed too complicated to optimally work in such deep reservoirs at this time.

  17. Assessment of the State-Of-The-Art of Numerical Simulation of Enhanced Geothermal Systems

    SciTech Connect

    1999-11-01

    The reservoir features of importance in the operation of enhanced geothermal systems are described first (Section 2). The report then reviews existing reservoir simulators developed for application to HDR reservoirs (Section 3), hydrothermal systems (Section 4), and nuclear waste isolation (Section 5), highlighting capabilities relevant to the evaluation and assessment of EGS. The report focuses on simulators that include some representation of flow in fractures, only mentioning other simulators, such as general-purpose programs or groundwater models (Section 6). Following these detailed descriptions, the report summarizes and comments on the simulators (Section 7), and recommends a course of action for further development (Section 8). The references are included in Section 9. Appendix A contains contractual information, including a description of the original and revised scope of work for this study. Appendix B presents comments on the draft report from DOE reviewer(s) and the replies of the authors to those comments. [DJE-2005

  18. Life Cycle Water Consumption and Water Resource Assessment for Utility-Scale Geothermal Systems: An In-Depth Analysis of Historical and Forthcoming EGS Projects

    SciTech Connect

    Schroeder, Jenna N.

    2013-08-31

    This report is the third in a series of reports sponsored by the U.S. Department of Energy Geothermal Technologies Program in which a range of water-related issues surrounding geothermal power production are evaluated. The first report made an initial attempt at quantifying the life cycle fresh water requirements of geothermal power-generating systems and explored operational and environmental concerns related to the geochemical composition of geothermal fluids. The initial analysis of life cycle fresh water consumption of geothermal power-generating systems identified that operational water requirements consumed the vast majority of water across the life cycle. However, it relied upon limited operational water consumption data and did not account for belowground operational losses for enhanced geothermal systems (EGSs). A second report presented an initial assessment of fresh water demand for future growth in utility-scale geothermal power generation. The current analysis builds upon this work to improve life cycle fresh water consumption estimates and incorporates regional water availability into the resource assessment to improve the identification of areas where future growth in geothermal electricity generation may encounter water challenges.

  19. Federal Geothermal Research Program Update Fiscal Year 2000

    SciTech Connect

    Renner, J.L.

    2001-08-15

    The Department of Energy's Geothermal Program serves two broad purposes: (1) to assist industry in overcoming near-term barriers by conducting cost-shared research and field verification that allows geothermal energy to compete in today's aggressive energy markets; and (2) to undertake fundamental research with potentially large economic payoffs. The four categories of work used to distinguish the research activities of the Geothermal Program during FY 2000 reflect the main components of real-world geothermal projects. These categories form the main sections of the project descriptions in this Research Update. Exploration Technology research focuses on developing instruments and techniques to discover hidden hydrothermal systems and to explore the deep portions of known systems. Research in geophysical and geochemical methods is expected to yield increased knowledge of hidden geothermal systems. Reservoir Technology research combines laboratory and analytical investigations with equipment development and field testing to establish practical tools for resource development and management for both hydrothermal reservoirs and enhanced geothermal systems. Research in various reservoir analysis techniques is generating a wide range of information that facilitates development of improved reservoir management tools. Drilling Technology focuses on developing improved, economic drilling and completion technology for geothermal wells. Ongoing research to avert lost circulation episodes in geothermal drilling is yielding positive results. Conversion Technology research focuses on reducing costs and improving binary conversion cycle efficiency, to permit greater use of the more abundant moderate-temperature geothermal resource, and on the development of materials that will improve the operating characteristics of many types of geothermal energy equipment. Increased output and improved performance of binary cycles will result from investigations in heat cycle research.

  20. An integrated multidisciplinary re-evaluation of the geothermal system at Valles Caldera, New Mexico, using an immersive three-dimensional (3D) visualization environment

    NASA Astrophysics Data System (ADS)

    Fowler, A.; Bennett, S. E.; Wildgoose, M.; Cantwell, C.; Elliott, A. J.

    2012-12-01

    We describe an approach to explore the spatial relationships of a geothermal resource by examining diverse geological, geophysical, and geochemical data sets using the immersive 3-dimensional (3D) visualization capabilities of the UC Davis Keck Center for Active Visualization in the Earth Sciences (KeckCAVES). The KeckCAVES is a facility where stereoscopic images are projected onto four, surfaces (three walls and a floor), which the user perceives as a seamless 3D image of the data. The user can manipulate and interact with the data, allowing a more intuitive interpretation of data set relationships than is possible with traditional 2-dimensional techniques. We incorporate multiple data sets of the geothermal system at Valles Caldera, New Mexico: topography, lithology, faults, temperature, alteration mineralogy, and magnetotellurics. With the ability to rapidly and intuitively observe data relationships, we are able to efficiently and rapidly draw conclusions about the subsurface architecture of the Valles Caldera geothermal system. We identify two high-temperature anomalies, one that corresponds with normal faults along the western caldera ring fracture, and one that with the resurgent dome. A cold-temperature anomaly identified adjacent to the resurgent dome high-temperature anomaly appears to relate to a fault controlled graben valley that acts as a recharge zone, likely funneling cold meteoric water into the subsurface along normal faults observed on published maps and cross sections. These high-temperature anomalies broadly correspond to subsurface regions where previous magnetotelluric studies have identified low apparent resistivity. Existing hot springs in the Sulfur Springs area correspond to the only location where our modeled 100°C isotherm intersects the ground surface. Correlation between the first occurrence of key alteration minerals (pyrite, chlorite, epidote) in previously drilled boreholes and our temperature model vary, with chlorite showing a

  1. The Coso geothermal area: A laboratory for advanced MEQ studies for geothermal monitoring

    USGS Publications Warehouse

    Julian, B.R.; Foulger, G.R.; Richards-Dinger, K.

    2004-01-01

    The permanent 16-station network of three-component digital seismometers at the Coso geothermal area, California, supplemented by 14 temporary instruments deployed in connection with the DOE Enhanced Geothermal Systems (EGS) Project, provides high-quality microearthquake (MEQ) recordings that are well suited to monitoring a producing geothermal area. We are currently using these data to investigate structure and active processes within the geothermal reservoir by applying three advanced methods: a) high-precision MEQ hypocenter location; b) time-dependent tomography; c) complete (moment tensor) MEQ source mechanism determination. Preliminary results to date resolve seismogenic structures in the producing field more clearly than is possible with conventional earthquake-location techniques. A shallow part of the producing field shows clear changes in the ratio of the seismic wave speeds, Vp/V s, between 1996 and 2002, which are probably related to physical changes in the reservoir caused by fluid extraction.

  2. Microbiological Aspects of Geothermal Energy: Influence of Microbial Activity on Scaling and Clogging in a Cold Storage

    NASA Astrophysics Data System (ADS)

    Lerm, Stephanie; Alawi, Mashal; Miethling-Graff, Rona; Vieth, Andrea; Seibt, Andrea; Wolfgramm, Markus; Würdemann, Hilke

    2010-05-01

    The development of strategies to substantially reduce emission of greenhouse gases to the atmosphere is one of the major challenges of the next decades. Therefore, the utilization of subsurface stored energy arouses increasing interest. Corrosion and scaling are major problems in geothermal operation which create significant maintenance and cleaning costs. In the scope of the research project AquiScreen the operational reliability of geothermal used aquifer systems was investigated under microbial, geochemical, mineralogical, and petrologic aspects (see also Alawi et al.; General Assembly EGU 2010). This presentation focuses on the investigation of a cold storage in Berlin (Reichstag building, depth 30-50 m). In order to evaluate the impact of microbial processes in the low saline aquifer (see also Vetter et al.; General Assembly EGU 2010), the microbial communities of fluid and filter samples were investigated by Fluorescent in situ hybridization (FISH) and DNA fingerprinting techniques based on PCR amplified partial 16S rRNA genes. Analyses of fluid samples revealed a bacterial community dominated by iron and sulfur oxidizing bacteria closely related to Siderooxidans lithoautotrophicus, Gallionella sp. and Thiotrix unzii. Scanning electron microscope analysis revealed iron hydroxide formation and precipitation in the filter of the top side facility and the well, corresponding to the abundance of iron oxidizing bacteria. Besides oxidizing bacteria sulfate reducing bacteria (SRB) were detected as well, indicating the formation of micro-habitats with divergent redox zones. After several years of operation and routine maintenance procedures the injectivity of the injection wells and the endurance of the top side facility filters were reduced drastically due to clogging. Mechanical cleaning and a disinfection treatment with hydrogen peroxide (H2O2) were successful to re-establish the injectivity of the wells. The results of the microbiological investigations prove

  3. The calculation of aquifer chemistry in hot-water geothermal systems

    USGS Publications Warehouse

    Truesdell, Alfred H.; Singers, Wendy

    1974-01-01

    The temperature and chemical conditions (pH, gas pressure, and ion activities) in a geothermal aquifer supplying a producing bore can be calculated from the enthalpy of the total fluid (liquid + vapor) produced and chemical analyses of water and steam separated and collected at known pressures. Alternatively, if a single water phase exists in the aquifer, the complete analysis (including gases) of a sample collected from the aquifer by a downhole sampler is sufficient to determine the aquifer chemistry without a measured value of the enthalpy. The assumptions made are that the fluid is produced from a single aquifer and is homogeneous in enthalpy and chemical composition. These calculations of aquifer chemistry involving large amounts of ancillary information and many iterations require computer methods. A computer program in PL-1 to perform these calculations is available from the National Technical Information Service as document PB-219 376.

  4. Geothermal Data via the Virginia Tech and DMME Portal to the National Geothermal Data System for the Eastern and Southeastern United States from the Regional Geophysics Laboratory of Virginia Polytechnic Institute and State University

    DOE Data Explorer

    The former title for this record was "Geothermal Data for the Eastern and Southeastern U.S. from the Regional Geophysics Laboratory of Virginia Tech." The content originally referenced is still available. It includes geothermal maps of seven southeastern states with accompanying data tables. The seven states are: New Jersey, Maryland, Delaware, Virginia, North Carolina, South Caroline, and Georgia. Data types include geothermal data, seismic data, and magnetic and gravity data. Typical geothermal data may include tables of temperature versus depth data, plots of temperature/gradient versus depth, tables of thermal conductivity data, and tables of gamma log data. Other resources available from the RGL provide information about hot springs in the southeastern U.S., temperatures for Atlantic Coastal Plain sediments, and deep fracture permeability in crystalline rocks in the eastern and southeastern U.S. Recently, this website and its collection of geothermal data has been renamed and reorganized as a portal into the National Geothermal Data System, a move that makes far more data both available and integrated.

  5. Analysis of Geologic Parameters on the Performance of CO2-Plume Geothermal (CPG) Systems in a Multi-Layered Reservoirs

    NASA Astrophysics Data System (ADS)

    Garapati, N.; Randolph, J.; Saar, M. O.

    2013-12-01

    CO2-Plume Geothermal (CPG) involves injection of CO2 as a working fluid to extract heat from naturally high permeable sedimentary basins. The injected CO2 forms a large subsurface CO2 plume that absorbs heat from the geothermal reservoir and eventually buoyantly rises to the surface. The heat density of sedimentary basins is typically relatively low.However, this drawback is likely counteracted by the large accessible volume of natural reservoirs compared to artificial, hydrofractured, and thus small-scale, reservoirs. Furthermore, supercritical CO2has a large mobility (inverse kinematic viscosity) and expansibility compared to water resulting in the formation of a strong thermosiphon which eliminates the need for parasitic pumping power requirements and significantly increasing electricity production efficiency. Simultaneously, the life span of the geothermal power plant can be increased by operating the CPG system such that it depletes the geothermal reservoir heat slowly. Because the produced CO2 is reinjected into the ground with the main CO2 sequestration stream coming from a CO2 emitter, all of the CO2 is ultimately geologically sequestered resulting in a CO2 sequestering geothermal power plant with a negative carbon footprint. Conventional geothermal process requires pumping of huge amount of water for the propagation of the fractures in the reservoir, but CPG process eliminates this requirement and conserves water resources. Here, we present results for performance of a CPG system as a function of various geologic properties of multilayered systemsincludingpermeability anisotropy, rock thermal conductivity, geothermal gradient, reservoir depth and initial native brine salinity as well as spacing between the injection and production wells. The model consists of a 50 m thick, radially symmetric grid with a semi-analytic heat exchange and no fluid flow at the top and bottom boundaries and no fluid and heat flow at the lateral boundaries. We design Plackett

  6. Quartz dissolution and silica deposition in hot-dry-rock geothermal systems

    SciTech Connect

    Robinson, B.A.

    1982-07-01

    The kinetics of quartz dissolution control the produced fluid dissolved silica concentration in geothermal systems in which the downhole residence time is finite. The produced fluid of the Phase I, Run Segment 5 experimental Hot Dry Rock (HDR) geothermal system at Fenton Hill, NM, was undersaturated with respect to quartz in one pass through the reservoir, suggesting that the rate of granite dissolution governed the outlet dissolved silica concentration in this system. The literature data for the rate of quartz dissolution in water from 65 to 625/sup 0/C is correlated using an empirical rate law which is first order in quartz surface area and degree of undersaturation of the fluid. The Arrhenius plot (ln k vs T/sup -1/) is linear over eight orders of magnitude of the rate constant, verifying the validity of the proposed rate expression. Carefully performed quartz dissolution experiments in the present study duplicated the literature data and completed the data base in the temperature range from 150 to 250/sup 0/C. Identical experiments using crushed granite indicate that the rate of quartz dissolution in the presence of granite could be as much as 1 to 2 orders of magnitude faster than the rates observed in the pure quartz experiments. A temperature dependent HDR reservoir model incorporates the quartz dissolution rate law to simulate the dissolved silica behavior during the Fenton Hill Run Segment 5 experiment. For this low-permeability, fracture-dominated reservoir, the assumptions of one-dimensional plug flow through a vertically-inclined rectangular fracture and one-dimensional rock heat conduction perpendicular to the direction of flow are employed. These simplifications lead to an analytical solution for the temperature field in the reservoir.

  7. Geothermal Energy

    SciTech Connect

    Steele, B.C.; Harman, G.; Pitsenbarger, J.

    1996-02-01

    Geothermal Energy Technology (GET) announces on a bimonthly basis the current worldwide information available on the technologies required for economic recovery of geothermal energy and its use as direct heat or for electric power production.

  8. Geothermal Energy.

    ERIC Educational Resources Information Center

    Reed, Marshall J.

    1979-01-01

    During 1978, exploration for geothermal energy continued at the same moderately low level of the past few years in most countries. The U.S. is the only country where the development of geothermal energy depends on private industry. (BB)

  9. A Self Potential study of the summit geothermal system of the Krafla volcano (Iceland).

    NASA Astrophysics Data System (ADS)

    Giulia Di Giuseppe, Maria; Troiano, Antonio; Somma, Renato; Carlino, Stefano; Troise, Claudia; De Natale, Giuseppe

    2016-04-01

    The Krafla central volcano is located on the North Iceland Rift Zone. The Krafla geothermal field is located in a large (8 km) collapse caldera that formed approximately 110 000 years ago. Rhyolite formations border the caldera and an extensive geothermal system occurs within it. A 100 km long and 5-10 km wide fissure swarm transects the volcano. These and the central constitute together the Krafla volcanic system. The caldera has been the site of extensive drilling for geothermal development. Drilling started in 1974 and a total of 43 wells have been drilled and at least two wells hit rhyolitic magma, at the depth of 1.5 and 2.1 km respectively. The subsurface structure of Krafla has been investigated by seismic, gravimetric, electromagnetic, and geodetic techniques. Good geophysical evidence confirms the presence of a shallow magma chamber under the central part of the caldera at about 3 km depth. The resistivity structure of the Krafla volcano has also been investigated, first by DC methods but later by joint application of MT and TEM. In the framework of the Krafla Magma Drilling Project (KMDP), a Self Potential (SP) survey has been realized in order to characterize the background flow pattern in the area. SP method measures the distribution of the electric potential at Earth surface generated in rocks because of various physical and chemical processes. The SP is the only method that is directly sensitive to the pattern of groundwater flow and to changes in the seepage velocity. At first, a NS profile crossing the IDDP-1 borehole site has been realized. A secondary profile, in a roughly EW direction orthogonal to the first one has been also performed. Both profiles have an approximate length of 4 km, which should be enough to characterize the flow pattern in the crust overlying the magma chamber. After the completion of the profiles, a first analysis through a probabilistic algorithm has been attempted. The findings has been used as starting constrain for a

  10. 2008 Geothermal Technologies Market Report