Science.gov

Sample records for active imaging systems

  1. Active imaging system with Faraday filter

    DOEpatents

    Snyder, J.J.

    1993-04-13

    An active imaging system has a low to medium powered laser transmitter and receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination while eliminating solar background.

  2. Active imaging system with Faraday filter

    DOEpatents

    Snyder, James J.

    1993-01-01

    An active imaging system has a low to medium powered laser transmitter and receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination while eliminating solar background.

  3. Active gated imaging in driver assistance system

    NASA Astrophysics Data System (ADS)

    Grauer, Yoav

    2014-04-01

    In this paper, we shall present the active gated imaging system (AGIS) in relation to the automotive field. AGIS is based on a fast-gated camera and pulsed illuminator, synchronized in the time domain to record images of a certain range of interest. A dedicated gated CMOS imager sensor and near infra-red (NIR) pulsed laser illuminator, is presented in this paper to provide active gated technology. In recent years, we have developed these key components and learned the system parameters, which are most beneficial to nighttime (in all weather conditions) driving in terms of field of view, illumination profile, resolution, and processing power. We shall present our approach of a camera-based advanced driver assistance systems (ADAS) named BrightEye™, which makes use of the AGIS technology in the automotive field.

  4. The active-passive continuous-wave terahertz imaging system

    NASA Astrophysics Data System (ADS)

    Dolganova, Irina N.; Zaytsev, Kirill I.; Metelkina, Anna A.; Yurchenko, Stanislav O.

    2016-08-01

    Active and passive terahertz (THz) imaging have recently become essential instruments of various THz applications. In this paper the active- and passive-mode THz imaging systems are studied and the hybrid active-passive THz imaging system is suggested. The concept of image contrast was used to compare the active and passive THz imaging results. In order to achieve better image quality the hybrid system is considered to be effective. The main advantage of the proposed system is the combination of the self-emitted radiation of the object with the back scattered source radiation. The experimental results demonstrate that the active-passive modality of THz imaging system allows retrieving maximum information about the object. An approach to synthesise the active-passive THz images was proposed using the false-color representation.

  5. Image change detection using a SWIR active imaging system

    NASA Astrophysics Data System (ADS)

    Schneider, Armin L.; Monnin, David; Laurenzis, Martin; Christnacher, Frank

    2013-10-01

    We are currently developing a system consisting of a GPS receiver, a three-axis magnetic compass as well as a digital video camera in order to visualize changes occuring along a regularily used itinerary. This is done by comparing actual images with images from the same scene, which have been acquired during a previous measurement. The luminosity of images from two different passages however can be quite different (due to different meteorological conditions). Whereas the global luminosity can be adjusted using non-linear luminosity correction, the treatment of shadows is more di cult. Since meteorological conditions cannot be controlled, we are investigating the possibility of using a Laser Gated Viewing system in the SWIR domain to illuminate the scene. Using appropriate filters for the camera, we are completely independent of natural illumination and in addition, the system can also be used at night.

  6. Deep trap, laser activated image converting system

    NASA Technical Reports Server (NTRS)

    Maserjian, J. (Inventor)

    1975-01-01

    Receiving an optical image on the surface of a photoconducting semiconductor is presented, storing the image in deep traps of the semiconductor, and later scanning the semiconductor with a laser beam to empty the deep traps, thereby producing a video signal. The semiconductor is illuminated with photons of energy greater than the band gap producing electron-hole pairs in the semiconductor which subsequently fill traps in energy from the band edges. When the laser beam of low energy photons excites the trapped electrons and holes out of the traps into the conduction and valence bands, a photoconductivity can be observed.

  7. Two generations of Canadian active imaging systems: ALBEDOS and ELVISS

    NASA Astrophysics Data System (ADS)

    Larochelle, Vincent; Mathieu, Pierre; Simard, Jean-Robert

    1999-07-01

    Search and rescue and general surveillance mission pose a serious challenge to conventional imaging systems used by actual aircraft crews. These systems must often work in low- light and low-visibility conditions to find the identify targets. A new airborne imaging technology has been developed to overcome several deficiencies encountered with common CCD cameras, image intensified system and thermal imaging sensors. The recent developments in laser diode arrays, laser diode beam collimation and gatable micro- channel plate intensifier have made possible the construction of a compact active imagin system, called the Airborne Laser-Based Enhanced Detection and Observation Systems (ALBEDOS). This system proved particularly efficient at night and in degraded weather conditions. In addition, it was demonstrated that range gating, besides eliminating most of the light backscattered by aerosols, provided to some extent immunity to blooming effects specific to highly sensitive cameras. The system was installed on a helicopter and tested in various scenarios in October 1995 to demonstrate its potential. To enhance the surveillance capability over large areas of coverage, to optimize detection of humans and small objects and to improve the effectiveness of the search aircraft, a second-generation payload is presently developed and combines the benefits of two complementary imaging sensors. The Enhanced Low-Light level Visible and IR Surveillance System (ELVISS) consists of an improved range-gated active imager and a high-quality thermal imager, installed in two separate airborne platforms slaved together and controlled by a single user interface. It is expected that such a sensor systems will have a direct impact on improving the response time in finding those in need of assistance or simply in increasing the performance, reliability and efficiency of crews involved in general surveillance operations. This paper explains the concept of range gating, details a preliminary

  8. Active multispectral imaging system for photodiagnosis and personalized phototherapies

    NASA Astrophysics Data System (ADS)

    Ugarte, M. F.; Chávarri, L.; Briz, S.; Padrón, V. M.; García-Cuesta, E.

    2014-10-01

    The proposed system has been designed to identify dermatopathologies or to apply personalized phototherapy treatments. The system emits electromagnetic waves in different spectral bands in the range of visible and near infrared to irradiate the target (skin or any other object) to be spectrally characterized. Then, an imaging sensor measures the target response to the stimulus at each spectral band and, after processing, the system displays in real time two images. In one of them the value of each pixel corresponds to the more reflected wavenumber whereas in the other image the pixel value represents the energy absorbed at each band. The diagnosis capability of this system lies in its multispectral design, and the phototherapy treatments are adapted to the patient and his lesion by measuring his absorption capability. This "in situ" absorption measurement allows us to determine the more appropriate duration of the treatment according to the wavelength and recommended dose. The main advantages of this system are its low cost, it does not have moving parts or complex mechanisms, it works in real time, and it is easy to handle. For these reasons its widespread use in dermatologist consultation would facilitate the work of the dermatologist and would improve the efficiency of diagnosis and treatment. In fact the prototype has already been successfully applied to pathologies such as carcinomas, melanomas, keratosis, and nevi.

  9. Active multispectral imaging system for photodiagnosis and personalized phototherapies

    SciTech Connect

    Ugarte, M. F. E-mail: sbriz@fis.uc3m.es; Chávarri, L.; Padrón, V. M.; García-Cuesta, E.

    2014-10-15

    The proposed system has been designed to identify dermatopathologies or to apply personalized phototherapy treatments. The system emits electromagnetic waves in different spectral bands in the range of visible and near infrared to irradiate the target (skin or any other object) to be spectrally characterized. Then, an imaging sensor measures the target response to the stimulus at each spectral band and, after processing, the system displays in real time two images. In one of them the value of each pixel corresponds to the more reflected wavenumber whereas in the other image the pixel value represents the energy absorbed at each band. The diagnosis capability of this system lies in its multispectral design, and the phototherapy treatments are adapted to the patient and his lesion by measuring his absorption capability. This “in situ” absorption measurement allows us to determine the more appropriate duration of the treatment according to the wavelength and recommended dose. The main advantages of this system are its low cost, it does not have moving parts or complex mechanisms, it works in real time, and it is easy to handle. For these reasons its widespread use in dermatologist consultation would facilitate the work of the dermatologist and would improve the efficiency of diagnosis and treatment. In fact the prototype has already been successfully applied to pathologies such as carcinomas, melanomas, keratosis, and nevi.

  10. Infrared active polarimetric imaging system controlled by image segmentation algorithms: application to decamouflage

    NASA Astrophysics Data System (ADS)

    Vannier, Nicolas; Goudail, François; Plassart, Corentin; Boffety, Matthieu; Feneyrou, Patrick; Leviandier, Luc; Galland, Frédéric; Bertaux, Nicolas

    2016-05-01

    We describe an active polarimetric imager with laser illumination at 1.5 µm that can generate any illumination and analysis polarization state on the Poincar sphere. Thanks to its full polarization agility and to image analysis of the scene with an ultrafast active-contour based segmentation algorithm, it can perform adaptive polarimetric contrast optimization. We demonstrate the capacity of this imager to detect manufactured objects in different types of environments for such applications as decamouflage and hazardous object detection. We compare two imaging modes having different number of polarimetric degrees of freedom and underline the characteristics that a polarimetric imager aimed at this type of applications should possess.

  11. Toward the development of an image quality tool for active millimeter wave imaging systems

    NASA Astrophysics Data System (ADS)

    Barber, Jeffrey; Weatherall, James C.; Greca, Joseph; Smith, Barry T.

    2015-05-01

    Preliminary design considerations for an image quality tool to complement millimeter wave imaging systems are presented. The tool is planned for use in confirming operating parameters; confirmation of continuity for imaging component design changes, and analysis of new components and detection algorithms. Potential embodiments of an image quality tool may contain materials that mimic human skin in order to provide a realistic signal return for testing, which may also help reduce or eliminate the need for mock passengers for developmental testing. Two candidate materials, a dielectric liquid and an iron-loaded epoxy, have been identified and reflection measurements have been performed using laboratory systems in the range 18 - 40 GHz. Results show good agreement with both laboratory and literature data on human skin, particularly in the range of operation of two commercially available millimeter wave imaging systems. Issues related to the practical use of liquids and magnetic materials for image quality tools are discussed.

  12. Integrated imaging sensor systems with CMOS active pixel sensor technology

    NASA Technical Reports Server (NTRS)

    Yang, G.; Cunningham, T.; Ortiz, M.; Heynssens, J.; Sun, C.; Hancock, B.; Seshadri, S.; Wrigley, C.; McCarty, K.; Pain, B.

    2002-01-01

    This paper discusses common approaches to CMOS APS technology, as well as specific results on the five-wire programmable digital camera-on-a-chip developed at JPL. The paper also reports recent research in the design, operation, and performance of APS imagers for several imager applications.

  13. CMOS active pixel sensor type imaging system on a chip

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R. (Inventor); Nixon, Robert (Inventor)

    2011-01-01

    A single chip camera which includes an .[.intergrated.]. .Iadd.integrated .Iaddend.image acquisition portion and control portion and which has double sampling/noise reduction capabilities thereon. Part of the .[.intergrated.]. .Iadd.integrated .Iaddend.structure reduces the noise that is picked up during imaging.

  14. Calculation of utmost parameters of active vision system based on nonscanning thermal imager

    NASA Astrophysics Data System (ADS)

    Sviridov, A. N.

    2003-09-01

    An active vision system (AVS) based on a non scanning thermal imager (TI) and CO2 - quantum amplifier of the image is offered. AVS mathematical model within which investigation of utmost signal / noise values and other system parameters depending on the distances to the scene - the area of observation (AO), an illumination impulse energy (W), an amplification factor (K) of a quantum amplifier, objective lens characteristics, spectral band width of a cooled filter of the thermal imager as well as object and scene characteristics is developed. Calculations were carried out for the following possible operating modes of a discussed vision system: - an active mode of a thermal imager with a cooled wideband filter; an active mode of a thermal imager with a cooled narrowband filter; - passive mode (W = 0, K = 1) of a thermal imager with a cooled wideband filter. As a result of carried out researches the opportunity and expediency of designing AVS, having a nonscanning thermal imager, impulse CO2 - quantum image amplifier and impulse CO2 - illumination laser are shown. It is shown that AVS have advantages over thermal imaging at observation of objects, temperature and reflection factors of which differ slightly from similar parameters of the scene. AVS depending on the W-K product can detect at a distance of up to 3000..5000m practically any local changes (you are interested in ) of a reflection factor. AVS not replacing the thermal imaging allow to receive additional information about observation objects. The images obtained with the help of AVS are more natural and more easy identified than thermal images received at the expense of the object own radiation. For quantitative determination of utmost values of AVS sensitivity it is offered to introduce a new parameter - NERD - 'radiation nose equivalent reflection factors difference'. IR active vision systems of vision, as well as a human vision and vision systems in the near IR - range on the basis image intensifiers

  15. Ultraviolet imaging spectroscopy shows an active saturnian system.

    PubMed

    Esposito, Larry W; Colwell, Joshua E; Larsen, Kristopher; McClintock, William E; Stewart, A Ian F; Hallett, Janet Tew; Shemansky, Donald E; Ajello, Joseph M; Hansen, Candice J; Hendrix, Amanda R; West, Robert A; Keller, H Uwe; Korth, Axel; Pryor, Wayne R; Reulke, Ralf; Yung, Yuk L

    2005-02-25

    Neutral oxygen in the saturnian system shows variability, and the total number of oxygen atoms peaks at 4 x 10(34). Saturn's aurora brightens in response to solar-wind forcing, and the auroral spectrum resembles Jupiter's. Phoebe's surface shows variable water-ice content, and the data indicate it originated in the outer solar system. Saturn's rings also show variable water abundance, with the purest ice in the outermost A ring. This radial variation is consistent with initially pure water ice bombarded by meteors, but smaller radial structures may indicate collisional transport and recent renewal events in the past 10(7) to 10(8) years.

  16. Imaging System

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The 1100C Virtual Window is based on technology developed under NASA Small Business Innovation (SBIR) contracts to Ames Research Center. For example, under one contract Dimension Technologies, Inc. developed a large autostereoscopic display for scientific visualization applications. The Virtual Window employs an innovative illumination system to deliver the depth and color of true 3D imaging. Its applications include surgery and Magnetic Resonance Imaging scans, viewing for teleoperated robots, training, and in aviation cockpit displays.

  17. Research on long-range laser active imaging system applied in adverse weather conditions

    NASA Astrophysics Data System (ADS)

    Gai, Zhi-gang; Liu, Meng-de; Yang, Li; Kabanov, V. V.; Shi, Lei; Zhao, Jie; Chu, Shi-bo; Yang, Jun-xian; Zhou, Yang

    2013-09-01

    A low-light level night vision device or thermal infrared imager belonging to passive imaging system is generally used in daily target detection and identification. But in adverse weather conditions of dark of night, poor atmospheric transmission characteristics or strong backscattering (fog, dust, rain, snow, etc.), even the most sensitive low-light level night vision could not provide enough image resolution for detecting and identifying targets, and the thermal infrared imager is also limited by low temperature contrast. A long-range laser active imaging system, in combination with high-power semiconductor pulsed lasers with collimation technology, receiving objective lens of large diameter, long focal length and narrow viewing angle, high-gain image intensifier CCD (ICCD) camera and range-gated synchronization control technology, is developed for long distance target detection and high resolution imaging in adverse weather conditions. The system composition and operating principle are introduced. The extremely powerful and efficient illuminators with collimation technology are able to deliver uniform beams, which are essential for illuminating targets at a distance and generating high-quality images. The particular receiving objective lens, ICCD camera and range-gated synchronization control technology could reduce strong backscattering signal and improve imaging signal-to-noise ratio. The laboratory and outfield experiments have been done to validate imaging effect and imaging quality. The results show that the minimum resolution is about 3-5cm, 10cm, and greater than 20 cm for target far from 1100m, 4700m, and 6700m respectively in dark of night. Furthermore, the minimum resolution could reach to 10cm and 20cm for target far from 2500m and 4800m respectively and the image is too blurred to accurately identify the target when observing the target far from 7200m in rainy condition.

  18. The analysis of solar activity features by means of the BASIS digital imaging system

    NASA Astrophysics Data System (ADS)

    Messerotti, M.; Lampi, L.; Furlani, S.; Zlobec, P.

    CCD-based digital imaging systems are powerful tools for the analysis of solar activity features in real-time or as post-processing. Despite the actual sensor-limited resolutions of low-cost systems, interesting projects can be carried out such as, for instance, the tracing of photospheric motions, in principle also in automatic mode. With regard to that BASIS, a digital imaging system for the sun operated at Trieste, will be briefly described. Possible applications as mentioned above will be discussed with emphasis on photospheric and chromospheric patterns.

  19. Wavelength-dependent radiometric modeling for an active geosynchronous satellite imaging system

    NASA Astrophysics Data System (ADS)

    Bush, Keith A.; Barnard, Calvin C.

    2000-10-01

    Recent interest in imaging satellites in geo-synchronous earth orbit has led to the design of a ground-based active imaging system using a concept known as Fourier Telescopy. Fourier Telescopy systems use active laser illumination, aperture synthesis, and extensive computer processing to minimize atmospheric turbulence effects and form high-resolution images of distant stationary objects. Three laser transmitters of slightly different frequency illuminate the object with varying baseline separations to temporally encode object spatial frequency information in the energy backscattered from the object. Detection and demodulation of the temporal signals and processing using phase closure and wavefront reconstruction techniques yield measurements of the object's incoherent Fourier amplitude and phase distribution. We have developed a detailed wave optics simulation to analyze and optimize the performance of this system. Wavelength dependent renderings of 3-D satellite models and the statistical variations of object illumination determine the radiometric returns received for a given scenario and the effect on imaging system performance. This work uses the simulation to examine system performance for three different illumination laser wavelengths and for realistic system design limitations. System design trade-offs based on the wavelength dependence of satellite optical cross-section, atmospheric propagation, and diffraction are discussed. Our results indicate that a near infra-red (IR) wavelength may be most suitable for this system.

  20. Active imaging with the aids of polarization retrieve in turbid media system

    NASA Astrophysics Data System (ADS)

    Tao, Qiangqiang; Sun, Yongxuan; Shen, Fei; Xu, Qiang; Gao, Jun; Guo, Zhongyi

    2016-01-01

    We propose a novel active imaging based on the polarization retrieve (PR) method in turbid media system. In our simulations, the Monte Carlo (MC) algorithm has been used to investigate the scattering process between the incident photons and the scattering particles, and the visually concordant object but with different polarization characteristics in different regions, has been selected as the original target that is placed in the turbid media. Under linearly and circularly polarized illuminations, the simulation results demonstrate that the corresponding polarization properties can provide additional information for the imaging, and the contrast of the polarization image can also be enhanced greatly compared to the simplex intensity image in the turbid media. Besides, the polarization image adjusted by the PR method can further enhance the visibility and contrast. In addition, by PR imaging method, with the increasing particles' size in Mie's scale, the visibility can be enhanced, because of the increased forward scattering effect. In general, in the same circumstance, the circular polarization images can offer a better contrast and visibility than that of linear ones. The results indicate that the PR imaging method is more applicable to the scattering media system with relatively larger particles such as aerosols, heavy fog, cumulus, and seawater, as well as to biological tissues and blood media.

  1. Design of an active millimeter-wave concealed-object imaging system

    NASA Astrophysics Data System (ADS)

    Paulter, Nicholas G.; Grossman, Erich N.; Stenbakken, G. N.; Waltrip, B. C.; Nolen, Shalva; Reintsema, Carl D.

    2001-08-01

    The research and design of an active millimeter-wave concealed object imaging system is described. Several illumination and detection methods were analyzed via computer simulation to assess the effects of system parameters on the signal-to-noise ratio of the detected signal. The results of many of these simulations were experimentally verified using either a 10 MHz or a 100 GHz measurement system. Based on this assessment, two design using pulsed illuminate with gated detection were selected for development. Pulsed illumination is provided using a pulsed broadband noise source. For detecting the reflected noise pulse, two methods were examined, one using micro bolometers and the other using electrooptics. Based on imaging system considerations, such as cost of manufacture, ruggedness, etc., and technical parameters, micro bolometer arrays were selected for further development. The electronics interface, including image display capability, was developed. We examined the absorption of some common clothing materials at 100 Ghz and compared this to results previously reported.

  2. Redox-initiated hydrogel system for detection and real-time imaging of cellulolytic enzyme activity.

    PubMed

    Malinowska, Klara H; Verdorfer, Tobias; Meinhold, Aylin; Milles, Lukas F; Funk, Victor; Gaub, Hermann E; Nash, Michael A

    2014-10-01

    Understanding the process of biomass degradation by cellulolytic enzymes is of urgent importance for biofuel and chemical production. Optimizing pretreatment conditions and improving enzyme formulations both require assays to quantify saccharification products on solid substrates. Typically, such assays are performed using freely diffusing fluorophores or dyes that measure reducing polysaccharide chain ends. These methods have thus far not allowed spatial localization of hydrolysis activity to specific substrate locations with identifiable morphological features. Here we describe a hydrogel reagent signaling (HyReS) system that amplifies saccharification products and initiates crosslinking of a hydrogel that localizes to locations of cellulose hydrolysis, allowing for imaging of the degradation process in real time. Optical detection of the gel in a rapid parallel format on synthetic and natural pretreated solid substrates was used to quantify activity of T. emersonii and T. reesei enzyme cocktails. When combined with total internal reflection fluorescence microscopy and AFM imaging, the reagent system provided a means to visualize enzyme activity in real-time with high spatial resolution (<2 μm). These results demonstrate the versatility of the HyReS system in detecting cellulolytic enzyme activity and suggest new opportunities in real-time chemical imaging of biomass depolymerization. PMID:25116339

  3. Active infrared hyperspectral imaging system using a broadly tunable optical parametric oscillator

    NASA Astrophysics Data System (ADS)

    Malcolm, G. P. A.; Maker, G. T.; Robertson, G.; Dunn, M. H.; Stothard, D. J. M.

    2009-09-01

    The in situ identification and spatial location of gases, discrete liquid droplets and residues on surfaces is a technically challenging problem. Active Infrared (IR) hyperspectral imaging is a powerful technique that combines real-time imaging and optical spectroscopy for "standoff" detection of suspected chemical substances, including chemical warfare agents, toxic industrial chemicals, explosives and narcotics. An active IR hyperspectral imaging system requires a coherent, broadly tunable IR light source of high spectral purity, in order to detect a broad range of target substances. In this paper we outline a compact and power-efficient IR illumination source with high stability, efficiency, tuning range and spectral purity based upon an optical parametric oscillator (OPO). The fusion of established OPO technology with novel diode-pumped laser technology and electro-mechanical scanning has enabled a broadly applicable imaging system. This system is capable of hyperspectral imaging at both Near-IR (1.3 - 1.9 μm) and Mid-IR (2.3 - 4.6 μm) wavelengths simultaneously with a line width of < 3 cm-1. System size and complexity are minimised by using a dual InGaAs/InSb single element detector, and images are acquired by raster scanning the coaxial signal and idler beams simultaneously, at ranges up to 20 m. Reflection, absorption and scatter of incident radiation by chemical targets and their surroundings provide a method for spatial location, and characteristic spectra obtained from each sample can be used to identify targets uniquely. To date, we have recognized liquids in sample sizes as small 20 μl-and gases with sensitivity as high as 10ppm.m-at detection standoff distances > 10 m.

  4. Unmasking Silent Endothelial Activation in the Cardiovascular System Using Molecular Magnetic Resonance Imaging

    PubMed Central

    Belliere, Julie; Martinez de Lizarrondo, Sara; Choudhury, Robin P.; Quenault, Aurélien; Le Béhot, Audrey; Delage, Christine; Chauveau, Dominique; Schanstra, Joost P.; Bascands, Jean-Loup; Vivien, Denis; Gauberti, Maxime

    2015-01-01

    Endothelial activation is a hallmark of cardiovascular diseases, acting either as a cause or a consequence of organ injury. To date, we lack suitable methods to measure endothelial activation in vivo. In the present study, we developed a magnetic resonance imaging (MRI) method allowing non-invasive endothelial activation mapping in the vasculature of the main organs affected during cardiovascular diseases. In clinically relevant contexts in mice (including systemic inflammation, acute and chronic kidney diseases, diabetes mellitus and normal aging), we provided evidence that this method allows detecting endothelial activation before any clinical manifestation of organ failure in the brain, kidney and heart with an exceptional sensitivity. In particular, we demonstrated that diabetes mellitus induces chronic endothelial cells activation in the kidney and heart. Moreover, aged mice presented activated endothelial cells in the kidneys and the cerebrovasculature. Interestingly, depending on the underlying condition, the temporospatial patterns of endothelial activation in the vascular beds of the cardiovascular system were different. These results demonstrate the feasibility of detecting silent endothelial activation occurring in conditions associated with high cardiovascular risk using molecular MRI. PMID:26379785

  5. Unmasking Silent Endothelial Activation in the Cardiovascular System Using Molecular Magnetic Resonance Imaging.

    PubMed

    Belliere, Julie; Martinez de Lizarrondo, Sara; Choudhury, Robin P; Quenault, Aurélien; Le Béhot, Audrey; Delage, Christine; Chauveau, Dominique; Schanstra, Joost P; Bascands, Jean-Loup; Vivien, Denis; Gauberti, Maxime

    2015-01-01

    Endothelial activation is a hallmark of cardiovascular diseases, acting either as a cause or a consequence of organ injury. To date, we lack suitable methods to measure endothelial activation in vivo. In the present study, we developed a magnetic resonance imaging (MRI) method allowing non-invasive endothelial activation mapping in the vasculature of the main organs affected during cardiovascular diseases. In clinically relevant contexts in mice (including systemic inflammation, acute and chronic kidney diseases, diabetes mellitus and normal aging), we provided evidence that this method allows detecting endothelial activation before any clinical manifestation of organ failure in the brain, kidney and heart with an exceptional sensitivity. In particular, we demonstrated that diabetes mellitus induces chronic endothelial cells activation in the kidney and heart. Moreover, aged mice presented activated endothelial cells in the kidneys and the cerebrovasculature. Interestingly, depending on the underlying condition, the temporospatial patterns of endothelial activation in the vascular beds of the cardiovascular system were different. These results demonstrate the feasibility of detecting silent endothelial activation occurring in conditions associated with high cardiovascular risk using molecular MRI.

  6. Imaging the magmatic system of Newberry Volcano using Joint active source and teleseismic tomography

    NASA Astrophysics Data System (ADS)

    Heath, Benjamin A.; Hooft, Emilie E. E.; Toomey, Douglas R.; Bezada, Maximiliano J.

    2015-12-01

    In this paper, we combine active and passive source P wave seismic data to tomographically image the magmatic system beneath Newberry Volcano, located east of the Cascade arc. By using both travel times from local active sources and delay times from teleseismic earthquakes recorded on closely spaced seismometers (300-800 m), we significantly improve recovery of upper crustal velocity structure (<10 km depth). The tomographic model reveals a low-velocity feature between 3 and 5 km depth that lies beneath the caldera, consistent with a magma body. In contrast to earlier tomographic studies, where elevated temperatures were sufficient to explain the recovered low velocities, the larger amplitude low-velocity anomalies in our joint tomography model require low degrees of partial melt (˜10%), and a minimum melt volume of ˜2.5 km3. Furthermore, synthetic tests suggest that even greater magnitude low-velocity anomalies, and by inference larger volumes of magma (up to 8 km3), are needed to explain the observed waveform variability. The lateral extent and shape of the inferred magma body indicates that the extensional tectonic regime at Newberry influences the emplacement of magmatic intrusions. Our study shows that jointly inverting active source and passive source seismic data improves tomographic imaging of the shallow crustal seismic structure of volcanic systems and that active source experiments would benefit from longer deployment times to also record teleseismic sources.

  7. Imaging evolutionarily conserved neural networks: preferential activation of the olfactory system by food-related odor.

    PubMed

    Kulkarni, Praveen; Stolberg, Tara; Sullivanjr, J M; Ferris, Craig F

    2012-04-21

    Rodents routinely forge and rely on hippocampal-dependent spatial memory to guide them to sources of caloric rich food in their environment. Has evolution affected the olfactory system and its connections to the hippocampus and limbic cortex, so rodents have an innate sensitivity to energy rich food and their location? To test this notion, we used functional magnetic resonance imaging in awake rats to observe changes in brain activity in response to four odors: benzaldehyde (almond odor), isoamyl acetate (banana odor), methyl benzoate (rosy odor), and limonene (citrus odor). We chose the almond odor because nuts are high in calories and would be expected to convey greater valance as compared to the other odors. Moreover, the standard food chow is devoid of nuts, so laboratory bred rats would not have any previous exposure to this food. Activation maps derived from computational analysis using a 3D segmented rat MRI atlas were dramatically different between odors. Animals exposed to banana, rosy and citrus odors showed modest activation of the primary olfactory system, hippocampus and limbic cortex. However, animals exposed to almond showed a robust increase in brain activity in the primary olfactory system particularly the main olfactory bulb, anterior olfactory nucleus and tenia tecta. The most significant difference in brain activation between odors was observed in the hippocampus and limbic cortex. These findings show that fMRI can be used to identify neural circuits that have an innate sensitivity to environmental stimuli that may help in an animal's survival. PMID:22343130

  8. Active millimeter-wave imaging system for material analysis and object detection

    NASA Astrophysics Data System (ADS)

    Zech, Christian; Hülsmann, Axel; Kallfass, Ingmar; Tessmann, Axel; Zink, Martin; Schlechtweg, Michael; Leuther, Arnulf; Ambacher, Oliver

    2011-11-01

    The use of millimeter-waves for imaging purposes is becoming increasingly important, as millimeter-waves can penetrate most clothing and packaging materials, so that the detector does not require physical contact with the object. This will offer a view to the hidden content of e.g. packets or bags without the need to open them, whereby packaging and content will not be damaged. Nowadays X-ray is used, but as the millimeter-wave quantum energy is far below the ionization energy, it is less harmful for the human health. In this paper we report an active millimeter-wave imaging tomograph for material analysis and concealed object detection purposes. The system is build using in-house W-band components. The object is illuminated with low-power millimeter-waves in the frequency range between 89 and 96GHz; mirrors are used to guide and focus the beam. The object is moved through the focus point to scan the object pixel by pixel. Depending on the actual material some parts of the waves are reflected, the other parts penetrate the object. A single-antenna transmit and receive module is used for illumination and measurement of the material-specific reflected power. A second receiver module is used to measure the transmitted wave. All information is processed for amplitude and phase images by a computer algorithm. The system can be used for security, such as detecting concealed weapons, explosives or contrabands at airports and other safety areas, but also quality assurance applications, e.g. during production to detect defects. Some imaging results will be presented in this paper.

  9. Miniaturized Three-Dimensional Endoscopic Imaging System Based on Active Stereovision

    NASA Astrophysics Data System (ADS)

    Chan, Manhong; Lin, Wumei; Zhou, Changhe; Qu, Jianan Y.

    2003-04-01

    A miniaturized three-dimensional endoscopic imaging system is presented. The system consists of two imaging channels that can be used to obtain an image from an object of interest and to project a structured light onto the imaged object to measure the surface topology. The structured light was generated with a collimated monochromatic light source and a holographic binary phase grating. The imaging and projection channels were calibrated by use of a modified pinhole camera. The surface profile was extracted by use of triangulation between the projected feature points and the two channels of the endoscope. The imaging system was evaluated in three-dimensional measurements of several objects with known geometries. The results show that surface profiles of the objects with different surfaces and dimensions can be obtained at high accuracy. The in vivo measurements at tissue sites of human skin and an oral cavity demonstrated the potential of the technique for clinical applications.

  10. The Europa Imaging System (EIS): Investigating Europa's geology, ice shell, and current activity

    NASA Astrophysics Data System (ADS)

    Turtle, Elizabeth; Thomas, Nicolas; Fletcher, Leigh; Hayes, Alexander; Ernst, Carolyn; Collins, Geoffrey; Hansen, Candice; Kirk, Randolph L.; Nimmo, Francis; McEwen, Alfred; Hurford, Terry; Barr Mlinar, Amy; Quick, Lynnae; Patterson, Wes; Soderblom, Jason

    2016-07-01

    NASA's Europa Mission, planned for launch in 2022, will perform more than 40 flybys of Europa with altitudes at closest approach as low as 25 km. The instrument payload includes the Europa Imaging System (EIS), a camera suite designed to transform our understanding of Europa through global decameter-scale coverage, topographic and color mapping, and unprecedented sub- meter-scale imaging. EIS combines narrow-angle and wide-angle cameras to address these science goals: • Constrain the formation processes of surface features by characterizing endogenic geologic structures, surface units, global cross-cutting relationships, and relationships to Europa's subsurface structure and potential near-surface water. • Search for evidence of recent or current activity, including potential plumes. • Characterize the ice shell by constraining its thickness and correlating surface features with subsurface structures detected by ice penetrating radar. • Characterize scientifically compelling landing sites and hazards by determining the nature of the surface at scales relevant to a potential lander. EIS Narrow-angle Camera (NAC): The NAC, with a 2.3°° x 1.2°° field of view (FOV) and a 10-μμrad instantaneous FOV (IFOV), achieves 0.5-m pixel scale over a 2-km-wide swath from 50-km altitude. A 2-axis gimbal enables independent targeting, allowing very high-resolution stereo imaging to generate digital topographic models (DTMs) with 4-m spatial scale and 0.5-m vertical precision over the 2-km swath from 50-km altitude. The gimbal also makes near-global (>95%) mapping of Europa possible at ≤50-m pixel scale, as well as regional stereo imaging. The NAC will also perform high-phase-angle observations to search for potential plumes. EIS Wide-angle Camera (WAC): The WAC has a 48°° x 24°° FOV, with a 218-μμrad IFOV, and is designed to acquire pushbroom stereo swaths along flyby ground-tracks. From an altitude of 50 km, the WAC achieves 11-m pixel scale over a 44-km

  11. Next-generation CMOS active pixel sensors for satellite hybrid optical communications/imaging sensor systems

    NASA Astrophysics Data System (ADS)

    Stirbl, Robert C.; Pain, Bedabrata; Cunningham, Thomas J.; Hancock, Bruce R.; McCarty, Kenneth P.

    1998-12-01

    Given the current choices of (1) an ever increasing population of large numbers of satellites in low-earth orbit (LEO) constellations for commercial and military global coverage systems, or (2) the alternative of smaller count geosynchronous satellite system constellations in high-earth (HEO), of higher cost and complexity, a number of commercial communications and military operations satellite systems designers are investigating the potential advantages and issues of operating in the mid-earth orbit altitudes (MEO) (between LEO and HEO). At these MEO altitudes both total dose and displacement damage can be traded against the system advantages of fewer satellites required. With growing demand for higher bandwidth communication for real-time earth observing satellite sensor systems, and NASA's interplanetary and deep space virtual unmanned exploration missions in stressing radiation environments, JPL is developing the next generation of smart sensors to address these new requirements of: low-cost, high bandwidth, miniaturization, ultra low-power and mission environment ruggedness. Radiation hardened/tolerant Active Pixel Sensor CMOS imagers that can be adaptively windowed with low power, on-chip control, timing, digital output and provide data-channel efficient on-chip compression, high bandwidth optical communications links are being designed and investigated to reduce size, weight and cost for common optics/hybrid architectures.

  12. Imaging brain activity during seizures in freely behaving rats using a miniature multi-modal imaging system

    PubMed Central

    Sigal, Iliya; Koletar, Margaret M.; Ringuette, Dene; Gad, Raanan; Jeffrey, Melanie; Carlen, Peter L.; Stefanovic, Bojana; Levi, Ofer

    2016-01-01

    We report on a miniature label-free imaging system for monitoring brain blood flow and blood oxygenation changes in awake, freely behaving rats. The device, weighing 15 grams, enables imaging in a ∼ 2 × 2 mm field of view with 4.4 μm lateral resolution and 1 − 8 Hz temporal sampling rate. The imaging is performed through a chronically-implanted cranial window that remains optically clear between 2 to > 6 weeks after the craniotomy. This imaging method is well suited for longitudinal studies of chronic models of brain diseases and disorders. In this work, it is applied to monitoring neurovascular coupling during drug-induced absence-like seizures 6 weeks following the craniotomy. PMID:27699123

  13. Imaging brain activity during seizures in freely behaving rats using a miniature multi-modal imaging system

    PubMed Central

    Sigal, Iliya; Koletar, Margaret M.; Ringuette, Dene; Gad, Raanan; Jeffrey, Melanie; Carlen, Peter L.; Stefanovic, Bojana; Levi, Ofer

    2016-01-01

    We report on a miniature label-free imaging system for monitoring brain blood flow and blood oxygenation changes in awake, freely behaving rats. The device, weighing 15 grams, enables imaging in a ∼ 2 × 2 mm field of view with 4.4 μm lateral resolution and 1 − 8 Hz temporal sampling rate. The imaging is performed through a chronically-implanted cranial window that remains optically clear between 2 to > 6 weeks after the craniotomy. This imaging method is well suited for longitudinal studies of chronic models of brain diseases and disorders. In this work, it is applied to monitoring neurovascular coupling during drug-induced absence-like seizures 6 weeks following the craniotomy.

  14. Active Imaging through Cirrus Clouds.

    PubMed

    Landesman, B; Kindilien, P; Pierson, R; Matson, C; Mosley, D

    1997-11-24

    The presence of clouds of ice particles in the uplink and downlink path of an illumination beam can severely impede the performance of an active imaging system. Depending on the optical depth of the cloud, i.e., its density and depth, the beam can be completely scattered and extinguished, or the beam can pass through the cloud with some fraction attenuated, scattered, and depolarized. In particular, subvisual cirrus clouds, i.e., high, thin cirrus clouds that cannot be observed from the ground, can affect the properties and alignment of both uplink and downlink beams. This paper discusses the potential for active imaging in the presence of cirrus clouds. We document field data results from an active imaging experiment conducted several years ago, which the authors believe to show the effects of cirrus clouds on an active imaging system. To verify these conclusions, we include the results of a simulation of the interaction of a coherent illumination scheme with a cirrus cloud.

  15. An efficient topology adaptation system for parametric active contour segmentation of 3D images

    NASA Astrophysics Data System (ADS)

    Abhau, Jochen; Scherzer, Otmar

    2008-03-01

    Active contour models have already been used succesfully for segmentation of organs from medical images in 3D. In implicit models, the contour is given as the isosurface of a scalar function, and therefore topology adaptations are handled naturally during a contour evolution. Nevertheless, explicit or parametric models are often preferred since user interaction and special geometric constraints are usually easier to incorporate. Although many researchers have studied topology adaptation algorithms in explicit mesh evolutions, no stable algorithm is known for interactive applications. In this paper, we present a topology adaptation system, which consists of two novel ingredients: A spatial hashing technique is used to detect self-colliding triangles of the mesh whose expected running time is linear with respect to the number of mesh vertices. For the topology change procedure, we have developed formulas by homology theory. During a contour evolution, we just have to choose between a few possible mesh retriangulations by local triangle-triangle intersection tests. Our algorithm has several advantages compared to existing ones: Since the new algorithm does not require any global mesh reparametrizations, it is very efficient. Since the topology adaptation system does not require constant sampling density of the mesh vertices nor especially smooth meshes, mesh evolution steps can be performed in a stable way with a rather coarse mesh. We apply our algorithm to 3D ultrasonic data, showing that accurate segmentation is obtained in some seconds.

  16. Dynamically re-configurable CMOS imagers for an active vision system

    NASA Technical Reports Server (NTRS)

    Yang, Guang (Inventor); Pain, Bedabrata (Inventor)

    2005-01-01

    A vision system is disclosed. The system includes a pixel array, at least one multi-resolution window operation circuit, and a pixel averaging circuit. The pixel array has an array of pixels configured to receive light signals from an image having at least one tracking target. The multi-resolution window operation circuits are configured to process the image. Each of the multi-resolution window operation circuits processes each tracking target within a particular multi-resolution window. The pixel averaging circuit is configured to sample and average pixels within the particular multi-resolution window.

  17. Medical imaging systems

    SciTech Connect

    Frangioni, John V

    2013-06-25

    A medical imaging system provides simultaneous rendering of visible light and diagnostic or functional images. The system may be portable, and may include adapters for connecting various light sources and cameras in open surgical environments or laparascopic or endoscopic environments. A user interface provides control over the functionality of the integrated imaging system. In one embodiment, the system provides a tool for surgical pathology.

  18. Flavoprotein Autofluorescence Imaging of Visual System Activity in Zebra Finches and Mice

    PubMed Central

    Michael, Neethu; Bischof, Hans-Joachim; Löwel, Siegrid

    2014-01-01

    Large-scale brain activity patterns can be visualized by optical imaging of intrinsic signals (OIS) based on activity-dependent changes in the blood oxygenation level. Another method, flavoprotein autofluorescence imaging (AFI), exploits the mitochondrial flavoprotein autofluorescence, which is enhanced during neuronal activity. In birds, topographic mapping of visual space has been shown in the visual wulst, the avian homologue of the mammalian visual cortex by using OIS. We here applied the AFI method to visualize topographic maps in the visual wulst because with OIS, which depends on blood flow changes, blood vessel artifacts often obscure brain activity maps. We then compared both techniques quantitatively in zebra finches and in C57Bl/6J mice using the same setup and stimulation conditions. In addition to experiments with craniotomized animals, we also examined mice with intact skull (in zebra finches, intact skull imaging is not feasible probably due to the skull construction). In craniotomized animals, retinotopic maps were obtained by both methods in both species. Using AFI, artifacts caused by blood vessels were generally reduced, the magnitude of neuronal activity significantly higher and the retinotopic map quality better than that obtained by OIS in both zebra finches and mice. In contrast, our measurements in non-craniotomized mice did not reveal any quantitative differences between the two methods. Our results thus suggest that AFI is the method of choice for investigations of visual processing in zebra finches. In mice, however, if researchers decide to use the advantages of imaging through the intact skull, they will not be able to exploit the higher signals obtainable by the AFI-method. PMID:24400130

  19. A Bioluminescence Assay System for Imaging Metal Cationic Activities in Urban Aerosols.

    PubMed

    Kim, Sung-Bae; Naganawa, Ryuichi; Murata, Shingo; Nakayama, Takayoshi; Miller, Simon; Senda, Toshiya

    2016-01-01

    A bioluminescence-based assay system was fabricated for an efficient determination of the activities of air pollutants. The following four components were integrated into this assay system: (1) an 8-channel assay platform uniquely designed for simultaneously sensing multiple optical samples, (2) single-chain probes illuminating toxic chemicals or heavy metal cations from air pollutants, (3) a microfluidic system for circulating medium mimicking the human body, and (4) the software manimulating the above system. In the protocol, we briefly introduce how to integrate the components into the system and the application to the illumination of the metal cationic activities in air pollutants. PMID:27424913

  20. A Bioluminescence Assay System for Imaging Metal Cationic Activities in Urban Aerosols.

    PubMed

    Kim, Sung-Bae; Naganawa, Ryuichi; Murata, Shingo; Nakayama, Takayoshi; Miller, Simon; Senda, Toshiya

    2016-01-01

    A bioluminescence-based assay system was fabricated for an efficient determination of the activities of air pollutants. The following four components were integrated into this assay system: (1) an 8-channel assay platform uniquely designed for simultaneously sensing multiple optical samples, (2) single-chain probes illuminating toxic chemicals or heavy metal cations from air pollutants, (3) a microfluidic system for circulating medium mimicking the human body, and (4) the software manimulating the above system. In the protocol, we briefly introduce how to integrate the components into the system and the application to the illumination of the metal cationic activities in air pollutants.

  1. Ultrasound Imaging System Video

    NASA Technical Reports Server (NTRS)

    2002-01-01

    In this video, astronaut Peggy Whitson uses the Human Research Facility (HRF) Ultrasound Imaging System in the Destiny Laboratory of the International Space Station (ISS) to image her own heart. The Ultrasound Imaging System provides three-dimension image enlargement of the heart and other organs, muscles, and blood vessels. It is capable of high resolution imaging in a wide range of applications, both research and diagnostic, such as Echocardiography (ultrasound of the heart), abdominal, vascular, gynecological, muscle, tendon, and transcranial ultrasound.

  2. Study of a dual mode SWIR active imaging system for direct imaging and non-line-of-sight vision

    NASA Astrophysics Data System (ADS)

    Laurenzis, Martin; Christnacher, Frank; Velten, Andreas

    2015-05-01

    The application of non-line of sight vision and see around a corner has been demonstrated in the recent past on laboratory level with round trip path lengths on the scale of 1 m as well as 10 m. This method uses a computational imaging approach to analyze the scattered information of objects which are hidden from the direct sensors field of view. Recent demonstrator systems were driven at laser wavelengths (800 nm and 532 nm) which are far from the eye-safe shortwave infrared (SWIR) wavelength band i.e. between 1.4 μm and 2 μm. Therefore, the application in public or inhabited areas is difficult with respect to international laser safety conventions. In the present work, the authors evaluate the application of recent eye safe laser sources and sensor devices for non-line of sight sensing and give predictions on range and resolution. Further, the realization of a dual mode concept is studied enabling both, the direct view on a scene and the indirect view on a hidden scene. While recent laser gated viewing sensors have high spatial resolution, their application in non-line of sight imaging suffer from a too low temporal resolution due to minimal sensor gate width of around 150 ns. On the other hand, Geiger-mode single photon counting devices have high temporal resolution, but their spatial resolution is (until now) limited to array sizes of some thousand sensor elements. In this publication the authors present detailed theoretical and experimental evaluations.

  3. Aerial Image Systems

    NASA Astrophysics Data System (ADS)

    Clapp, Robert E.

    1987-09-01

    Aerial images produce the best stereoscopic images of the viewed world. Despite the fact that every optic in existence produces an aerial image, few persons are aware of their existence and possible uses. Constant reference to the eye and other optical systems have produced a psychosis of design that only considers "focal planes" in the design and analysis of optical systems. All objects in the field of view of the optical device are imaged by the device as an aerial image. Use of aerial images in vision and visual display systems can provide a true stereoscopic representation of the viewed world. This paper discusses aerial image systems - their applications and designs and presents designs and design concepts that utilize aerial images to obtain superior visual displays, particularly with application to visual simulation.

  4. Medical image processing system

    NASA Astrophysics Data System (ADS)

    Wang, Dezong; Wang, Jinxiang

    1994-12-01

    In this paper a medical image processing system is described. That system is named NAI200 Medical Image Processing System and has been appraised by Chinese Government. Principles and cases provided here. Many kinds of pictures are used in modern medical diagnoses, for example B-supersonic, X-ray, CT and MRI. Some times the pictures are not good enough for diagnoses. The noises interfere with real situation on these pictures. That means the image processing is needed. A medical image processing system is described in this paper. That system is named NAI200 Medical Image Processing System and has been appraised by Chinese Government. There are four functions in that system. The first part is image processing. More than thirty four programs are involved. The second part is calculating. The areas or volumes of single or multitissues are calculated. Three dimensional reconstruction is the third part. The stereo images of organs or tumors are reconstructed with cross-sections. The last part is image storage. All pictures can be transformed to digital images, then be stored in hard disk or soft disk. In this paper not only all functions of that system are introduced, also the basic principles of these functions are explained in detail. This system has been applied in hospitals. The images of hundreds of cases have been processed. We describe the functions combining real cases. Here we only introduce a few examples.

  5. Multi Spectral Imaging System

    NASA Technical Reports Server (NTRS)

    Spiering, Bruce A. (Inventor)

    1999-01-01

    An optical imaging system provides automatic co-registration of a plurality of multi spectral images of an object which are generated by a plurality of video cameras or other optical detectors. The imaging system includes a modular assembly of beam splitters, lens tubes, camera lenses and wavelength selective filters which facilitate easy reconfiguration and adjustment of the system for various applications. A primary lens assembly generates a real image of an object to be imaged on a reticle which is positioned at a fixed length from a beam splitter assembly. The beam splitter assembly separates a collimated image beam received from the reticle into multiple image beams, each of which is projected onto a corresponding one of a plurality of video cameras. The lens tubes which connect the beam splitter assembly to the cameras are adjustable in length to provide automatic co-registration of the images generated by each camera.

  6. Spectrographic imaging system

    DOEpatents

    Morris, Michael D.; Treado, Patrick J.

    1991-01-01

    An imaging system for providing spectrographically resolved images. The system incorporates a one-dimensional spatial encoding mask which enables an image to be projected onto a two-dimensional image detector after spectral dispersion of the image. The dimension of the image which is lost due to spectral dispersion on the two-dimensional detector is recovered through employing a reverse transform based on presenting a multiplicity of different spatial encoding patterns to the image. The system is especially adapted for detecting Raman scattering of monochromatic light transmitted through or reflected from physical samples. Preferably, spatial encoding is achieved through the use of Hadamard mask which selectively transmits or blocks portions of the image from the sample being evaluated.

  7. Imaging performance of elliptical-boundary varifocal mirrors in active optical systems

    NASA Astrophysics Data System (ADS)

    Lukes, Sarah Jane

    Micro-electro-mechanical systems deformable-membrane mirrors provide a means of focus control and attendant spherical aberration correction for miniaturized imaging systems. The technology has greatly advanced in the last decade, thereby extending their focal range capabilities. This dissertation describes a novel SU-8 2002 silicon-on-insulator wafer deformable mirror. A 4.000 mm x 5.657 mm mirror for 45o incident light rays achieves 22 mum stroke or 65 diopters, limited by snapdown. The mirrors show excellent optical quality while flat. Most have peak-to-valley difference of less than 150 nm and root-mean-square less than 25 nm. The process proves simple, only requiring a silicon-on-insulator wafer, SU-8 2002, and a metal layer. Xenon difluoride etches the silicon to release the mirrors. Greater than 90% of the devices survive fabrication and release. While current literature includes several aberration analyses on static mirrors, analyses that incorporate the dynamic nature of these mirrors do not exist. Optical designers may have a choice between deformable mirrors and other types of varifocal mirrors or lenses. Furthermore, a dynamic mirror at an incidence angle other than normal may be desired due to space limitations or for higher throughput (normal incidence requires a beam splitter). This dissertation presents an analysis based on the characteristic function of the system. It provides 2nd and 3rd order aberration coefficients in terms of dynamic focus range and base ray incidence angle. These afford an understanding of the significance of different types of aberrations. Root-mean-square and Strehl calculations provide insight into overall imaging performance for various conditions. I present general guidelines for maximum incidence angle and field of fiew that provide near diffraction-limited performance. Experimental verification of the MEMS mirrors at 5o and 45o incidence angles validates the analytical results. A Blu-ray optical pick-up imaging

  8. Multipurpose Hyperspectral Imaging System

    NASA Technical Reports Server (NTRS)

    Mao, Chengye; Smith, David; Lanoue, Mark A.; Poole, Gavin H.; Heitschmidt, Jerry; Martinez, Luis; Windham, William A.; Lawrence, Kurt C.; Park, Bosoon

    2005-01-01

    A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral imaging with or without relative movement of the imaging system, and it can be used to scan a target of any size as long as the target can be imaged at the focal plane; for example, automated inspection of food items and identification of single-celled organisms. The spectral resolution of this system is greater than that of prior terrestrial multispectral imaging systems. Moreover, unlike prior high-spectral resolution airborne and spaceborne hyperspectral imaging systems, this system does not rely on relative movement of the target and the imaging system to sweep an imaging line across a scene. This compact system (see figure) consists of a front objective mounted at a translation stage with a motorized actuator, and a line-slit imaging spectrograph mounted within a rotary assembly with a rear adaptor to a charged-coupled-device (CCD) camera. Push-broom scanning is carried out by the motorized actuator which can be controlled either manually by an operator or automatically by a computer to drive the line-slit across an image at a focal plane of the front objective. To reduce the cost, the system has been designed to integrate as many as possible off-the-shelf components including the CCD camera and spectrograph. The system has achieved high spectral and spatial resolutions by using a high-quality CCD camera, spectrograph, and front objective lens. Fixtures for attachment of the system to a microscope (U.S. Patent 6,495,818 B1) make it possible to acquire multispectral images of single cells and other microscopic objects.

  9. Activity-based costing via an information system: an application created for a breast imaging center.

    PubMed

    Hawkins, H; Langer, J; Padua, E; Reaves, J

    2001-06-01

    Activity-based costing (ABC) is a process that enables the estimation of the cost of producing a product or service. More accurate than traditional charge-based approaches, it emphasizes analysis of processes, and more specific identification of both direct and indirect costs. This accuracy is essential in today's healthcare environment, in which managed care organizations necessitate responsible and accountable costing. However, to be successfully utilized, it requires time, effort, expertise, and support. Data collection can be tedious and expensive. By integrating ABC with information management (IM) and systems (IS), organizations can take advantage of the process orientation of both, extend and improve ABC, and decrease resource utilization for ABC projects. In our case study, we have examined the process of a multidisciplinary breast center. We have mapped the constituent activities and established cost drivers. This information has been structured and included in our information system database for subsequent analysis.

  10. Activity-based costing via an information system: an application created for a breast imaging center.

    PubMed

    Hawkins, H; Langer, J; Padua, E; Reaves, J

    2001-06-01

    Activity-based costing (ABC) is a process that enables the estimation of the cost of producing a product or service. More accurate than traditional charge-based approaches, it emphasizes analysis of processes, and more specific identification of both direct and indirect costs. This accuracy is essential in today's healthcare environment, in which managed care organizations necessitate responsible and accountable costing. However, to be successfully utilized, it requires time, effort, expertise, and support. Data collection can be tedious and expensive. By integrating ABC with information management (IM) and systems (IS), organizations can take advantage of the process orientation of both, extend and improve ABC, and decrease resource utilization for ABC projects. In our case study, we have examined the process of a multidisciplinary breast center. We have mapped the constituent activities and established cost drivers. This information has been structured and included in our information system database for subsequent analysis. PMID:11442093

  11. Image Processing System

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.

  12. Imaging the complexity of an active normal fault system: The 1997 Colfiorito (central Italy) case study

    USGS Publications Warehouse

    Chiaraluce, L.; Ellsworth, W.L.; Chiarabba, C.; Cocco, M.

    2003-01-01

    Six moderate magnitude earthquakes (5 < Mw < 6) ruptured normal fault segments of the southern sector of the North Apennine belt (central Italy) in the 1997 Colfiorito earthquake sequence. We study the progressive activation of adjacent and nearby parallel faults of this complex normal fault system using ???1650 earthquake locations obtained by applying a double-difference location method, using travel time picks and waveform cross-correlation measurements. The lateral extent of the fault segments range from 5 to 10 km and make up a broad, ???45 km long, NW trending fault system. The geometry of each segment is quite simple and consists of planar faults gently dipping toward SW with an average dip of 40??-45??. The fault planes are not listric but maintain a constant dip through the entire seismogenic volume, down to 8 km depth. We observe the activation of faults on the hanging wall and the absence of seismicity in the footwall of the structure. The observed fault segmentation appears to be due to the lateral heterogeneity of the upper crust: preexisting thrusts inherited from Neogene's compressional tectonic intersect the active normal faults and control their maximum length. The stress tensor obtained by inverting the six main shock focal mechanisms of the sequence is in agreement with the tectonic stress active in the inner chain of the Apennine, revealing a clear NE trending extension direction. Aftershock focal mechanisms show a consistent extensional kinematics, 70% of which are mechanically consistent with the main shock stress field.

  13. Three-dimensional motion estimation using genetic algorithms from image sequence in an active stereo vision system

    NASA Astrophysics Data System (ADS)

    Dipanda, Albert; Ajot, Jerome; Woo, Sanghyuk

    2003-06-01

    This paper proposes a method for estimating 3D rigid motion parameters from an image sequence of a moving object. The 3D surface measurement is achieved using an active stereovision system composed of a camera and a light projector, which illuminates objects to be analyzed by a pyramid-shaped laser beam. By associating the laser rays and the spots in the 2D image, the 3D points corresponding to these spots are reconstructed. Each image of the sequence provides a set of 3D points, which is modeled by a B-spline surface. Therefore, estimating the motion between two images of the sequence boils down to matching two B-spline surfaces. We consider the matching environment as an optimization problem and find the optimal solution using Genetic Algorithms. A chromosome is encoded by concatenating six binary coded parameters, the three angles of rotation and the x-axis, y-axis and z-axis translations. We have defined an original fitness function to calculate the similarity measure between two surfaces. The matching process is performed iteratively: the number of points to be matched grows as the process advances and results are refined until convergence. Experimental results with a real image sequence are presented to show the effectiveness of the method.

  14. An Efficient Correction Algorithm for Eliminating Image Misalignment Effects on Co-Phasing Measurement Accuracy for Segmented Active Optics Systems.

    PubMed

    Yue, Dan; Xu, Shuyan; Nie, Haitao; Wang, Zongyang

    2016-01-01

    The misalignment between recorded in-focus and out-of-focus images using the Phase Diversity (PD) algorithm leads to a dramatic decline in wavefront detection accuracy and image recovery quality for segmented active optics systems. This paper demonstrates the theoretical relationship between the image misalignment and tip-tilt terms in Zernike polynomials of the wavefront phase for the first time, and an efficient two-step alignment correction algorithm is proposed to eliminate these misalignment effects. This algorithm processes a spatial 2-D cross-correlation of the misaligned images, revising the offset to 1 or 2 pixels and narrowing the search range for alignment. Then, it eliminates the need for subpixel fine alignment to achieve adaptive correction by adding additional tip-tilt terms to the Optical Transfer Function (OTF) of the out-of-focus channel. The experimental results demonstrate the feasibility and validity of the proposed correction algorithm to improve the measurement accuracy during the co-phasing of segmented mirrors. With this alignment correction, the reconstructed wavefront is more accurate, and the recovered image is of higher quality.

  15. An Efficient Correction Algorithm for Eliminating Image Misalignment Effects on Co-Phasing Measurement Accuracy for Segmented Active Optics Systems

    PubMed Central

    Yue, Dan; Xu, Shuyan; Nie, Haitao; Wang, Zongyang

    2016-01-01

    The misalignment between recorded in-focus and out-of-focus images using the Phase Diversity (PD) algorithm leads to a dramatic decline in wavefront detection accuracy and image recovery quality for segmented active optics systems. This paper demonstrates the theoretical relationship between the image misalignment and tip-tilt terms in Zernike polynomials of the wavefront phase for the first time, and an efficient two-step alignment correction algorithm is proposed to eliminate these misalignment effects. This algorithm processes a spatial 2-D cross-correlation of the misaligned images, revising the offset to 1 or 2 pixels and narrowing the search range for alignment. Then, it eliminates the need for subpixel fine alignment to achieve adaptive correction by adding additional tip-tilt terms to the Optical Transfer Function (OTF) of the out-of-focus channel. The experimental results demonstrate the feasibility and validity of the proposed correction algorithm to improve the measurement accuracy during the co-phasing of segmented mirrors. With this alignment correction, the reconstructed wavefront is more accurate, and the recovered image is of higher quality. PMID:26934045

  16. Medical imaging systems

    SciTech Connect

    Frangioni, John V.

    2012-07-24

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remains in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may also employ dyes or other fluorescent substances associated with antibodies, antibody fragments, or ligands that accumulate within a region of diagnostic significance. In one embodiment, the system provides an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide that is used to capture images. In another embodiment, the system is configured for use in open surgical procedures by providing an operating area that is closed to ambient light. More broadly, the systems described herein may be used in imaging applications where a visible light image may be usefully supplemented by an image formed from fluorescent emissions from a fluorescent substance that marks areas of functional interest.

  17. Visions image operating system

    SciTech Connect

    Kohler, R.R.; Hanson, A.R.

    1982-01-01

    The image operating system is a complete software environment specifically designed for dynamic experimentation in scene analysis. The IOS consists of a high-level interpretive control language (LISP) with efficient image operators in a noninterpretive language. The image operators are viewed as local operators to be applied in parallel at all pixels to a set of input images. In order to carry out complex image analysis experiments an environment conducive to such experimentation was needed. This environment is provided by the visions image operating system based on a computational structure known as a processing cone proposed by Hanson and Riseman (1974, 1980) and implemented on a VAX-11/780 running VMS. 6 references.

  18. Spaceborne electronic imaging systems

    NASA Technical Reports Server (NTRS)

    1971-01-01

    Criteria and recommended practices for the design of the spaceborne elements of electronic imaging systems are presented. A spaceborne electronic imaging system is defined as a device that collects energy in some portion of the electromagnetic spectrum with detector(s) whose direct output is an electrical signal that can be processed (using direct transmission or delayed transmission after recording) to form a pictorial image. This definition encompasses both image tube systems and scanning point-detector systems. The intent was to collect the design experience and recommended practice of the several systems possessing the common denominator of acquiring images from space electronically and to maintain the system viewpoint rather than pursuing specialization in devices. The devices may be markedly different physically, but each was designed to provide a particular type of image within particular limitations. Performance parameters which determine the type of system selected for a given mission and which influence the design include: Sensitivity, Resolution, Dynamic range, Spectral response, Frame rate/bandwidth, Optics compatibility, Image motion, Radiation resistance, Size, Weight, Power, and Reliability.

  19. Imaging the lymphatic system.

    PubMed

    Munn, Lance L; Padera, Timothy P

    2014-11-01

    Visualization of the lymphatic system is clinically necessary during diagnosis or treatment of many conditions and diseases; it is used for identifying and monitoring lymphedema, for detecting metastatic lesions during cancer staging and for locating lymphatic structures so they can be spared during surgical procedures. Imaging lymphatic anatomy and function also plays an important role in experimental studies of lymphatic development and function, where spatial resolution and accessibility are better. Here, we review technologies for visualizing and imaging the lymphatic system for clinical applications. We then describe the use of lymphatic imaging in experimental systems as well as some of the emerging technologies for improving these methodologies.

  20. Imaging the lymphatic system

    PubMed Central

    Munn, Lance L.; Padera, Timothy P.

    2014-01-01

    Visualization of the lymphatic system is clinically necessary during diagnosis or treatment of many conditions and diseases; it is used for identifying and monitoring lymphedema, for detecting metastatic lesions during cancer staging and for locating lymphatic structures so they can be spared during surgical procedures. Imaging lymphatic anatomy and function also plays an important role in experimental studies of lymphatic development and function, where spatial resolution and accessibility are better. Here, we review technologies for visualizing and imaging the lymphatic system for clinical applications. We then describe the use of lymphatic imaging in experimental systems as well as some of the emerging technologies for improving these methodologies. PMID:24956510

  1. Nuclear medicine imaging system

    DOEpatents

    Bennett, G.W.; Brill, A.B.; Bizais, Y.J.C.; Rowe, R.W.; Zubal, I.G.

    1983-03-11

    It is an object of this invention to provide a nuclear imaging system having the versatility to do positron annihilation studies, rotating single or opposed camera gamma emission studies, and orthogonal gamma emission studies. It is a further object of this invention to provide an imaging system having the capability for orthogonal dual multipinhole tomography. It is another object of this invention to provide a nuclear imaging system in which all available energy data, as well as patient physiological data, are acquired simultaneously in list mode.

  2. Quantitative luminescence imaging system

    DOEpatents

    Erwin, David N.; Kiel, Johnathan L.; Batishko, Charles R.; Stahl, Kurt A.

    1990-01-01

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopie imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber.

  3. Quantitative luminescence imaging system

    DOEpatents

    Erwin, D.N.; Kiel, J.L.; Batishko, C.R.; Stahl, K.A.

    1990-08-14

    The QLIS images and quantifies low-level chemiluminescent reactions in an electromagnetic field. It is capable of real time nonperturbing measurement and simultaneous recording of many biochemical and chemical reactions such as luminescent immunoassays or enzyme assays. The system comprises image transfer optics, a low-light level digitizing camera with image intensifying microchannel plates, an image process or, and a control computer. The image transfer optics may be a fiber image guide with a bend, or a microscope, to take the light outside of the RF field. Output of the camera is transformed into a localized rate of cumulative digitalized data or enhanced video display or hard-copy images. The system may be used as a luminescent microdosimetry device for radiofrequency or microwave radiation, as a thermal dosimeter, or in the dosimetry of ultra-sound (sonoluminescence) or ionizing radiation. It provides a near-real-time system capable of measuring the extremely low light levels from luminescent reactions in electromagnetic fields in the areas of chemiluminescence assays and thermal microdosimetry, and is capable of near-real-time imaging of the sample to allow spatial distribution analysis of the reaction. It can be used to instrument three distinctly different irradiation configurations, comprising (1) RF waveguide irradiation of a small Petri-dish-shaped sample cell, (2) RF irradiation of samples in a microscope for the microscopic imaging and measurement, and (3) RF irradiation of small to human body-sized samples in an anechoic chamber. 22 figs.

  4. Acoustic imaging system

    DOEpatents

    Smith, Richard W.

    1979-01-01

    An acoustic imaging system for displaying an object viewed by a moving array of transducers as the array is pivoted about a fixed point within a given plane. A plurality of transducers are fixedly positioned and equally spaced within a laterally extending array and operatively directed to transmit and receive acoustic signals along substantially parallel transmission paths. The transducers are sequentially activated along the array to transmit and receive acoustic signals according to a preestablished sequence. Means are provided for generating output voltages for each reception of an acoustic signal, corresponding to the coordinate position of the object viewed as the array is pivoted. Receptions from each of the transducers are presented on the same display at coordinates corresponding to the actual position of the object viewed to form a plane view of the object scanned.

  5. Combined terahertz imaging system for enhanced imaging quality

    NASA Astrophysics Data System (ADS)

    Dolganova, Irina N.; Zaytsev, Kirill I.; Metelkina, Anna A.; Yakovlev, Egor V.; Karasik, Valeriy E.; Yurchenko, Stanislav O.

    2016-06-01

    An improved terahertz (THz) imaging system is proposed for enhancing image quality. Imaging scheme includes THz source and detection system operated in active mode as well as in passive one. In order to homogeneously illuminate the object plane the THz reshaper is proposed. The form and internal structure of the reshaper were studied by the numerical simulation. Using different test-objects we compare imaging quality in active and passive THz imaging modes. Imaging contrast and modulation transfer functions in active and passive imaging modes show drawbacks of them in high and low spatial frequencies, respectively. The experimental results confirm the benefit of combining both imaging modes into hybrid one. The proposed algorithm of making hybrid THz image is an effective approach of retrieving maximum information about the remote object.

  6. Radiation imaging system

    DOEpatents

    Immel, David M.; Bobbit, III, John T.; Plummer, Jean R.; Folsom, Matthew D.; Serrato, Michael G.

    2016-03-22

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  7. Radiation imaging system

    DOEpatents

    Bobbitt, III, John T.; Immel, David M.; Folsom, Matthew D.; Plummer, Jean R.; Serrato, Michael G.

    2016-06-28

    A radiation imaging system includes a casing and a camera disposed inside the casing. A first field of view through the casing exposes the camera to light from outside of the casing. An image plate is disposed inside the casing, and a second field of view through the casing to the image plate exposes the image plate to high-energy particles produced by a radioisotope outside of the casing. An optical reflector that is substantially transparent to the high-energy particles produced by the radioisotope is disposed with respect to the camera and the image plate to reflect light to the camera and to allow the high-energy particles produced by the radioisotope to pass through the optical reflector to the image plate.

  8. Noninvasive imaging of prefrontal activation during attention-demanding tasks performed while walking using a wearable optical topography system

    NASA Astrophysics Data System (ADS)

    Atsumori, Hirokazu; Kiguchi, Masashi; Katura, Takusige; Funane, Tsukasa; Obata, Akiko; Sato, Hiroki; Manaka, Takaaki; Iwamoto, Mitsumasa; Maki, Atsushi; Koizumi, Hideaki; Kubota, Kisou

    2010-07-01

    Optical topography (OT) based on near-infrared spectroscopy is a noninvasive technique for mapping the relative concentration changes in oxygenated and deoxygenated hemoglobin (oxy- and deoxy-Hb, respectively) in the human cerebral cortex. In our previous study, we developed a small and light wearable optical topography (WOT) system that covers the entire forehead for monitoring prefrontal activation. In the present study, we examine whether the WOT system is applicable to OT measurement while walking, which has been difficult with conventional OT systems. We conduct OT measurements while subjects perform an attention-demanding (AD) task of balancing a ping-pong ball on a small card while walking. The measured time course and power spectra of the relative concentration changes in oxy- and deoxy-Hb show that the step-related changes in the oxy- and deoxy-Hb signals are negligible compared to the task-related changes. Statistical assessment of the task-related changes in the oxy-Hb signals show that the dorsolateral prefrontal cortex and rostral prefrontal area are significantly activated during the AD task. These results suggest that our functional imaging technique with the WOT system is applicable to OT measurement while walking, and will be a powerful tool for evaluating brain activation in a natural environment.

  9. A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

    NASA Technical Reports Server (NTRS)

    Kelly, Kenneth C.; Huang, John

    2000-01-01

    A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L- Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

  10. A Dual Polarization, Active, Microstrip Antenna for an Orbital Imaging Radar System Operating at L-Band

    NASA Technical Reports Server (NTRS)

    Kelly, Kenneth C.; Huang, John

    1999-01-01

    A highly successful Earth orbiting synthetic antenna aperture radar (SAR) system, known as the SIR-C mission, was carried into orbit in 1994 on a U.S. Shuttle (Space Transportation System) mission. The radar system was mounted in the cargo bay with no need to fold, or in any other way reduce the size of the antennas for launch. Weight and size were not limited for the L-Band, C-Band, and X-Band radar systems of the SIR-C radar imaging mission; the set of antennas weighed 10,500 kg, the L-Band antenna having the major share of the weight. This paper treats designing an L-Band antenna functionally similar to that used for SIR-C, but at a fraction of the cost and at a weight in the order of 250 kg. Further, the antenna must be folded to fit into the small payload shroud of low cost booster rocket systems. Over 31 square meters of antenna area is required. This low weight, foldable, electronic scanning antenna is for the proposed LightSAR radar system which is to be placed in Earth orbit on a small, dedicated space craft at the lowest possible cost for an efficient L-Band radar imaging system. This LightSAR spacecraft radar is to be continuously available for at least five operational years, and have the ability to map or repeat-map any area on earth within a few days of any request. A microstrip patch array, with microstrip transmission lines heavily employed in the aperture and in the corporate feed network, was chosen as the low cost approach for this active dual-polarization, 80 MHz (6.4%) bandwidth antenna design.

  11. Cardiac Imaging System

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Although not available to all patients with narrowed arteries, balloon angioplasty has expanded dramatically since its introduction with an estimated further growth to 562,000 procedures in the U.S. alone by 1992. Growth has fueled demand for higher quality imaging systems that allow the cardiologist to be more accurate and increase the chances of a successful procedure. A major advance is the Digital Cardiac Imaging (DCI) System designed by Philips Medical Systems International, Best, The Netherlands and marketed in the U.S. by Philips Medical Systems North America Company. The key benefit is significantly improved real-time imaging and the ability to employ image enhancement techniques to bring out added details. Using a cordless control unit, the cardiologist can manipulate images to make immediate assessment, compare live x-ray and roadmap images by placing them side-by-side on monitor screens, or compare pre-procedure and post procedure conditions. The Philips DCI improves the cardiologist's precision by expanding the information available to him.

  12. Advanced imaging system

    NASA Technical Reports Server (NTRS)

    1992-01-01

    This document describes the Advanced Imaging System CCD based camera. The AIS1 camera system was developed at Photometric Ltd. in Tucson, Arizona as part of a Phase 2 SBIR contract No. NAS5-30171 from the NASA/Goddard Space Flight Center in Greenbelt, Maryland. The camera project was undertaken as a part of the Space Telescope Imaging Spectrograph (STIS) project. This document is intended to serve as a complete manual for the use and maintenance of the camera system. All the different parts of the camera hardware and software are discussed and complete schematics and source code listings are provided.

  13. Multipurpose hyperspectral imaging system

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A hyperspectral imaging system of high spectral and spatial resolution that incorporates several innovative features has been developed to incorporate a focal plane scanner (U.S. Patent 6,166,373). This feature enables the system to be used for both airborne/spaceborne and laboratory hyperspectral i...

  14. Scorpion image segmentation system

    NASA Astrophysics Data System (ADS)

    Joseph, E.; Aibinu, A. M.; Sadiq, B. A.; Bello Salau, H.; Salami, M. J. E.

    2013-12-01

    Death as a result of scorpion sting has been a major public health problem in developing countries. Despite the high rate of death as a result of scorpion sting, little report exists in literature of intelligent device and system for automatic detection of scorpion. This paper proposed a digital image processing approach based on the floresencing characteristics of Scorpion under Ultra-violet (UV) light for automatic detection and identification of scorpion. The acquired UV-based images undergo pre-processing to equalize uneven illumination and colour space channel separation. The extracted channels are then segmented into two non-overlapping classes. It has been observed that simple thresholding of the green channel of the acquired RGB UV-based image is sufficient for segmenting Scorpion from other background components in the acquired image. Two approaches to image segmentation have also been proposed in this work, namely, the simple average segmentation technique and K-means image segmentation. The proposed algorithm has been tested on over 40 UV scorpion images obtained from different part of the world and results obtained show an average accuracy of 97.7% in correctly classifying the pixel into two non-overlapping clusters. The proposed 1system will eliminate the problem associated with some of the existing manual approaches presently in use for scorpion detection.

  15. Imaging of enzyme activity using bio-LSI system enables simultaneous immunosensing of different analytes in multiple specimens.

    PubMed

    Hokuto, Toshiki; Yasukawa, Tomoyuki; Kunikata, Ryota; Suda, Atsushi; Inoue, Kumi Y; Ino, Kosuke; Matsue, Tomokazu; Mizutani, Fumio

    2016-06-01

    Electrochemical imaging is an excellent technique to characterize an activity of biomaterials, such as enzymes and cells. Large scale integration-based amperometric sensor (Bio-LSI) has been developed for the simultaneous and continuous detection of the concentration distribution of redox species generated by reactions of biomolecules. In this study, the Bio-LSI system was demonstrated to be applicable for simultaneous detection of different anaytes in multiple specimens. The multiple specimens containing human immunoglobulin G (hIgG) and mouse IgG (mIgG) were introduced into each channel of the upper substrate across the antibody lines for hIgG and mIgG on the lower substrate. Hydrogen peroxide generated by the enzyme reaction of glucose oxidase captured at intersections was simultaneously detected by 400 microelectrodes of Bio-LSI chip. The oxidation current increased with increasing the concentrations of hIgG, which can be detected in the range of 0.01-1.0 µg mL(-1) . Simultaneous detection of hIgG and mIgG in multiple specimens was achieved by using line pattern of both antibodies. Therefore, the presence of different target molecules in the multiple samples would be quantitatively and simultaneously visualized as a current image by the Bio-LSI system. PMID:27150897

  16. Non-linear responsivity characterisation of a CMOS Active Pixel Sensor for high resolution imaging of the Jovian system

    NASA Astrophysics Data System (ADS)

    Soman, M.; Stefanov, K.; Weatherill, D.; Holland, A.; Gow, J.; Leese, M.

    2015-02-01

    The Jovian system is the subject of study for the Jupiter Icy Moon Explorer (JUICE), an ESA mission which is planned to launch in 2022. The scientific payload is designed for both characterisation of the magnetosphere and radiation environment local to the spacecraft, as well as remote characterisation of Jupiter and its satellites. A key instrument on JUICE is the high resolution and wide angle camera, JANUS, whose main science goals include detailed characterisation and study phases of three of the Galilean satellites, Ganymede, Callisto and Europa, as well as studies of other moons, the ring system, and irregular satellites. The CIS115 is a CMOS Active Pixel Sensor from e2v technologies selected for the JANUS camera. It is fabricated using 0.18 μ m CMOS imaging sensor process, with an imaging area of 2000 × 1504 pixels, each 7 μ m square. A 4T pixel architecture allows for efficient correlated double sampling, improving the readout noise to better than 8 electrons rms, whilst the sensor is operated in a rolling shutter mode, sampling at up to 10 Mpixel/s at each of the four parallel outputs.A primary parameter to characterise for an imaging device is the relationship that converts the sensor's voltage output back to the corresponding number of electrons that were detected in a pixel, known as the Charge to Voltage Factor (CVF). In modern CMOS sensors with small feature sizes, the CVF is known to be non-linear with signal level, therefore a signal-dependent measurement of the CIS115's CVF has been undertaken and is presented here. The CVF is well modelled as a quadratic function leading to a measurement of the maximum charge handling capacity of the CIS115 to be 3.4 × 104 electrons. If the CIS115's response is assumed linear, its CVF is 21.1 electrons per mV (1/47.5 μ V per electron).

  17. Flame Imaging System

    NASA Technical Reports Server (NTRS)

    Barnes, Heidi L. (Inventor); Smith, Harvey S. (Inventor)

    1998-01-01

    A system for imaging a flame and the background scene is discussed. The flame imaging system consists of two charge-coupled-device (CCD) cameras. One camera uses a 800 nm long pass filter which during overcast conditions blocks sufficient background light so the hydrogen flame is brighter than the background light, and the second CCD camera uses a 1100 nm long pass filter, which blocks the solar background in full sunshine conditions such that the hydrogen flame is brighter than the solar background. Two electronic viewfinders convert the signal from the cameras into a visible image. The operator can select the appropriate filtered camera to use depending on the current light conditions. In addition, a narrow band pass filtered InGaAs sensor at 1360 nm triggers an audible alarm and a flashing LED if the sensor detects a flame, providing additional flame detection so the operator does not overlook a small flame.

  18. Advanced imaging communication system

    NASA Technical Reports Server (NTRS)

    Hilbert, E. E.; Rice, R. F.

    1977-01-01

    Key elements of system are imaging and nonimaging sensors, data compressor/decompressor, interleaved Reed-Solomon block coder, convolutional-encoded/Viterbi-decoded telemetry channel, and Reed-Solomon decoding. Data compression provides efficient representation of sensor data, and channel coding improves reliability of data transmission.

  19. Active optical zoom system

    DOEpatents

    Wick, David V.

    2005-12-20

    An active optical zoom system changes the magnification (or effective focal length) of an optical imaging system by utilizing two or more active optics in a conventional optical system. The system can create relatively large changes in system magnification with very small changes in the focal lengths of individual active elements by leveraging the optical power of the conventional optical elements (e.g., passive lenses and mirrors) surrounding the active optics. The active optics serve primarily as variable focal-length lenses or mirrors, although adding other aberrations enables increased utility. The active optics can either be LC SLMs, used in a transmissive optical zoom system, or DMs, used in a reflective optical zoom system. By appropriately designing the optical system, the variable focal-length lenses or mirrors can provide the flexibility necessary to change the overall system focal length (i.e., effective focal length), and therefore magnification, that is normally accomplished with mechanical motion in conventional zoom lenses. The active optics can provide additional flexibility by allowing magnification to occur anywhere within the FOV of the system, not just on-axis as in a conventional system.

  20. Tactical Imaging System

    NASA Astrophysics Data System (ADS)

    Mocenter, Michael M.

    1990-02-01

    The ability to send photographic information to command centers is a vital element in performing effective near real-time reconnaissance and surveillance operations. This imagery, in conjunction with other battlefield data, provides the battlefield commander with up-to-date intelligence for making decisions. Until recently, the ability to provide this real-time information was severely restricted by the logistics of physically moving, developing, and then disseminating the film. This time delay resulted in out-of-date, stale intelligence. This problem situation has eased recently due to technological developments that have been instrumental in facilitating the dissemination of near real-time information to forward operating areas and behind enemy lines. The Naval Air Development Center (NAVAIRDEVCEN) has capitalized on these developments and established the Tactical Imaging System (TIS). This miniaturized, man-pack, SATCOM/HF transmitting system provides near real-time tactical imagery. It consists of an image sensor, image intensifier, zoom lens, and image transmission processor. This paper provides an overview of the TIS components, specifications, operations, and future developments and applications. The TIS will have potential application in areas such as identification (friend or foe), reconnaissance, surveillance, and battlefield assessment. Under the TIS program, NAVAIRDEVCEN has developed hands-on experience in still video images and related technologies, including fleet satellite communications, HF transmission, image compression algorithms, VSLI integrated circuitry design, and day/night imagery techniques. NAVAIRDEVCEN has developed a complete, miniaturized system to conduct operational demonstrations, and to demonstrate operational tactics and utilization concepts. This paper provides an overview of the TIS components, specifications, operations, and future developments and applications.

  1. Fueling and imaging brain activation.

    PubMed

    Dienel, Gerald A

    2012-01-01

    Metabolic signals are used for imaging and spectroscopic studies of brain function and disease and to elucidate the cellular basis of neuroenergetics. The major fuel for activated neurons and the models for neuron-astrocyte interactions have been controversial because discordant results are obtained in different experimental systems, some of which do not correspond to adult brain. In rats, the infrastructure to support the high energetic demands of adult brain is acquired during postnatal development and matures after weaning. The brain's capacity to supply and metabolize glucose and oxygen exceeds demand over a wide range of rates, and the hyperaemic response to functional activation is rapid. Oxidative metabolism provides most ATP, but glycolysis is frequently preferentially up-regulated during activation. Underestimation of glucose utilization rates with labelled glucose arises from increased lactate production, lactate diffusion via transporters and astrocytic gap junctions, and lactate release to blood and perivascular drainage. Increased pentose shunt pathway flux also causes label loss from C1 of glucose. Glucose analogues are used to assay cellular activities, but interpretation of results is uncertain due to insufficient characterization of transport and phosphorylation kinetics. Brain activation in subjects with low blood-lactate levels causes a brain-to-blood lactate gradient, with rapid lactate release. In contrast, lactate flooding of brain during physical activity or infusion provides an opportunistic, supplemental fuel. Available evidence indicates that lactate shuttling coupled to its local oxidation during activation is a small fraction of glucose oxidation. Developmental, experimental, and physiological context is critical for interpretation of metabolic studies in terms of theoretical models. PMID:22612861

  2. Fueling and imaging brain activation

    PubMed Central

    Dienel, Gerald A

    2012-01-01

    Metabolic signals are used for imaging and spectroscopic studies of brain function and disease and to elucidate the cellular basis of neuroenergetics. The major fuel for activated neurons and the models for neuron–astrocyte interactions have been controversial because discordant results are obtained in different experimental systems, some of which do not correspond to adult brain. In rats, the infrastructure to support the high energetic demands of adult brain is acquired during postnatal development and matures after weaning. The brain's capacity to supply and metabolize glucose and oxygen exceeds demand over a wide range of rates, and the hyperaemic response to functional activation is rapid. Oxidative metabolism provides most ATP, but glycolysis is frequently preferentially up-regulated during activation. Underestimation of glucose utilization rates with labelled glucose arises from increased lactate production, lactate diffusion via transporters and astrocytic gap junctions, and lactate release to blood and perivascular drainage. Increased pentose shunt pathway flux also causes label loss from C1 of glucose. Glucose analogues are used to assay cellular activities, but interpretation of results is uncertain due to insufficient characterization of transport and phosphorylation kinetics. Brain activation in subjects with low blood-lactate levels causes a brain-to-blood lactate gradient, with rapid lactate release. In contrast, lactate flooding of brain during physical activity or infusion provides an opportunistic, supplemental fuel. Available evidence indicates that lactate shuttling coupled to its local oxidation during activation is a small fraction of glucose oxidation. Developmental, experimental, and physiological context is critical for interpretation of metabolic studies in terms of theoretical models. PMID:22612861

  3. Quantitative Luminescence Imaging System

    SciTech Connect

    Batishko, C.R.; Stahl, K.A.; Fecht, B.A.

    1992-12-31

    The goal of the MEASUREMENT OF CHEMILUMINESCENCE project is to develop and deliver a suite of imaging radiometric instruments for measuring spatial distributions of chemiluminescence. Envisioned deliverables include instruments working at the microscopic, macroscopic, and life-sized scales. Both laboratory and field portable instruments are envisioned. The project also includes development of phantoms as enclosures for the diazoluminomelanin (DALM) chemiluminescent chemistry. A suite of either phantoms in a variety of typical poses, or phantoms that could be adjusted to a variety of poses, is envisioned. These are to include small mammals (rats), mid-sized mammals (monkeys), and human body parts. A complete human phantom that can be posed is a long-term goal of the development. Taken together, the chemistry and instrumentation provide a means for imaging rf dosimetry based on chemiluminescence induced by the heat resulting from rf energy absorption. The first delivered instrument, the Quantitative Luminescence Imaging System (QLIS), resulted in a patent, and an R&D Magazine 1991 R&D 100 award, recognizing it as one of the 100 most significant technological developments of 1991. The current status of the project is that three systems have been delivered, several related studies have been conducted, two preliminary human hand phantoms have been delivered, system upgrades have been implemented, and calibrations have been maintained. Current development includes sensitivity improvements to the microscope-based system; extension of the large-scale (potentially life-sized targets) system to field portable applications; extension of the 2-D large-scale system to 3-D measurement; imminent delivery of a more refined human hand phantom and a rat phantom; rf, thermal and imaging subsystem integration; and continued calibration and upgrade support.

  4. Imaging Hidden Water in Three Dimensions Using an Active Airborne Electromagnetic System

    NASA Astrophysics Data System (ADS)

    Wynn, J.

    2001-05-01

    The San Pedro Basin aquifer in southeastern Arizona and northern Mexico is important not only for local agriculture and residential communities, but also because it is the source of the San Pedro River. Declared a Riparian Conservation Area by Congress in 1988, the San Pedro is a critical element of one of four major migratory bird fly-ways over North America. The basin crosses the international frontier, extending into northern Mexico, where about 12,000 acre-ft of water is withdrawn yearly by the Cananea Mine. An additional 11,000 acre-ft is withdrawn by the US Army base at Fort Huachuca and surrounding towns including Sierra Vista. About 6,000 to 8,000 acre-ft of water is also estimated as lost to evapotranspiration, while recharge (mainly from the Huachuca Mountains) ranges from 12,500 to 15,000 acre-ft per year. This apparent net deficit is considered a serious threat by environmental groups to the integrity of the Riparian Conservation Area. Efforts have been underway to develop catchments and to implement water-conservation measures, but these have been hampered by a lack of detailed knowledge of the three-dimensional geometry and extent of the aquifer beneath the entire basin - at least until recently. In an effort to identify subcomponents and interconnectivities within the San Pedro Basin aquifer, the US Army funded several airborne EM surveys, conducted in 1997 and 1999 under the supervision of the US Geological Survey east of Fort Huachuca. These surveys used the Geoterrex GEOTEM system with 20 gated time-domain windows in three perpendicular orientations. The 60+ channel information was inverted using two different methods into conductivity-depth transforms, i.e., conductivity vs. depth along each flight-line. The resulting inversions have been assembled into a three-dimensional map of the aquifer, which in this arid region is quite conductive (the average is 338 micro-S/cm, around 30 ohm-meters). The coverage is about 1,000 square kilometers down to a

  5. Imaging system fundamentals

    NASA Astrophysics Data System (ADS)

    Holst, Gerald C.

    2011-05-01

    Point-and-shoot, TV studio broadcast, and thermal infrared imaging cameras have significantly different applications. A parameter that applies to all imaging systems is Fλ/d, where F is the focal ratio, λ is the wavelength, and d is the detector size. Fλ/d uniquely defines the shape of the camera modulation transfer function. When Fλ/d<2, aliased signal corrupts the imagery. Mathematically, the worst case analysis assumes that the scene contains all spatial frequencies with equal amplitudes. This quantifies the potential for aliasing and is called the spurious response. Digital data cannot be seen; it resides in a computer. Cathode ray tubes, flat panel displays, and printers convert the data into an analog format and are called reconstruction filters. The human visual system is an additional reconstruction filter. Different displays and variable viewing distance affect the perceived image quality. Simulated imagery illustrates different Fλ/d ratios, displays, and sampling artifacts. Since the human visual system is primarily sensitive to intensity variations, aliasing (a spatial frequency phenomenon) is not considered bothersome in most situations.

  6. EDITORIAL: Imaging systems and techniques Imaging systems and techniques

    NASA Astrophysics Data System (ADS)

    Yang, Wuqiang; Giakos, George; Nikita, Konstantina; Pastorino, Matteo; Karras, Dimitrios

    2009-10-01

    and nano-clinics for optical diagnostics and targeted therapy, can play an important role in the diagnosis and treatment of cancer. These techniques can also be used to provide efficient drug delivery for treatment of other diseases, with increased sensitivity and specificity. Similarly, enhanced stand-off detection, classification, identification and surveillance techniques, for comprehensive civilian and military target protection and enhanced space situational awareness can open new frontiers of research and applications in the defence arena and homeland security. For instance, the development of potential imaging sensor architectures, enhanced remote sensing systems, ladars, lidars and radars can provide data capable of ensuring continuous monitoring of various imaging/physical/chemical parameters under different operating conditions, using both active and passive detection principles, reconfigurable and scalable focal plane array architectures, reliable systems for stand-off detection of explosives, and enhanced airport security. The above areas pose challenging problems to the technical community and indicate an ever-growing need for innovative and auspicious solutions. We would like to thank all authors for their valuable contributions, without which this special issue would not have become reality.

  7. CMOS Imaging Device for Optical Imaging of Biological Activities

    NASA Astrophysics Data System (ADS)

    Shishido, Sanshiro; Oguro, Yasuhiro; Noda, Toshihiko; Sasagawa, Kiyotaka; Tokuda, Takashi; Ohta, Jun

    In this paper, we propose a CMOS image sensor device placed on the brain surface or cerebral sulcus (Fig. 1). The device has a photo detector array where a single optical detector is usually used. The proposed imaging device enables the analysis which reflects a surface blood pattern in the observed area. It is also possible to improve effective sensitivity by image processing and to simplify the measurement system by the CMOS sensor device with on-chip light source. We describe the design details and characterization of proposed device. We also demonstrate detection of hemoglobin oxygenation level with external light source, imaging capability of biological activities, and image processing for sensitivity improvement is also realized.

  8. Heart Imaging System

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Johnson Space Flight Center's device to test astronauts' heart function in microgravity has led to the MultiWire Gamma Camera, which images heart conditions six times faster than conventional devices. Dr. Jeffrey Lacy, who developed the technology as a NASA researcher, later formed Proportional Technologies, Inc. to develop a commercially viable process that would enable use of Tantalum-178 (Ta-178), a radio-pharmaceutical. His company supplies the generator for the radioactive Ta-178 to Xenos Medical Systems, which markets the camera. Ta-178 can only be optimally imaged with the camera. Because the body is subjected to it for only nine minutes, the radiation dose is significantly reduced and the technique can be used more frequently. Ta-178 also enables the camera to be used on pediatric patients who are rarely studied with conventional isotopes because of the high radiation dosage.

  9. A study on the application of near infrared hyperspectral chemical imaging for monitoring moisture content and water activity in low moisture systems.

    PubMed

    Achata, Eva; Esquerre, Carlos; O'Donnell, Colm; Gowen, Aoife

    2015-01-01

    Moisture content and water activity are key parameters in predicting the stability of low moisture content products. However, conventional methods for moisture content and water activity determination (e.g., loss on drying method, ‎Karl Fischer titration, dew point method) are time consuming, demand specialized equipment and are not amenable to online processing. For this reason they are typically applied at-line on a limited number of samples. Near infrared hyperspectral chemical imaging is an emerging technique for spatially characterising the spectral properties of samples. Due to the fast acquisition of chemical images, many samples can be evaluated simultaneously, thus providing the potential for online evaluation of samples during processing. In this study, the potential of NIR chemical imaging for predicting the moisture content and water activity of a selection of low moisture content food systems is evaluated. PMID:25654530

  10. Active confocal imaging for visual prostheses.

    PubMed

    Jung, Jae-Hyun; Aloni, Doron; Yitzhaky, Yitzhak; Peli, Eli

    2015-06-01

    There are encouraging advances in prosthetic vision for the blind, including retinal and cortical implants, and other "sensory substitution devices" that use tactile or electrical stimulation. However, they all have low resolution, limited visual field, and can display only few gray levels (limited dynamic range), severely restricting their utility. To overcome these limitations, image processing or the imaging system could emphasize objects of interest and suppress the background clutter. We propose an active confocal imaging system based on light-field technology that will enable a blind user of any visual prosthesis to efficiently scan, focus on, and "see" only an object of interest while suppressing interference from background clutter. The system captures three-dimensional scene information using a light-field sensor and displays only an in-focused plane with objects in it. After capturing a confocal image, a de-cluttering process removes the clutter based on blur difference. In preliminary experiments we verified the positive impact of confocal-based background clutter removal on recognition of objects in low resolution and limited dynamic range simulated phosphene images. Using a custom-made multiple-camera system based on light-field imaging, we confirmed that the concept of a confocal de-cluttered image can be realized effectively.

  11. Active confocal imaging for visual prostheses

    PubMed Central

    Jung, Jae-Hyun; Aloni, Doron; Yitzhaky, Yitzhak; Peli, Eli

    2014-01-01

    There are encouraging advances in prosthetic vision for the blind, including retinal and cortical implants, and other “sensory substitution devices” that use tactile or electrical stimulation. However, they all have low resolution, limited visual field, and can display only few gray levels (limited dynamic range), severely restricting their utility. To overcome these limitations, image processing or the imaging system could emphasize objects of interest and suppress the background clutter. We propose an active confocal imaging system based on light-field technology that will enable a blind user of any visual prosthesis to efficiently scan, focus on, and “see” only an object of interest while suppressing interference from background clutter. The system captures three-dimensional scene information using a light-field sensor and displays only an in-focused plane with objects in it. After capturing a confocal image, a de-cluttering process removes the clutter based on blur difference. In preliminary experiments we verified the positive impact of confocal-based background clutter removal on recognition of objects in low resolution and limited dynamic range simulated phosphene images. Using a custom-made multiple-camera system, we confirmed that the concept of a confocal de-cluttered image can be realized effectively using light field imaging. PMID:25448710

  12. Submillimeter Confocal Imaging Active Module

    NASA Technical Reports Server (NTRS)

    Hong, John; Mehdi, Imran; Siegel, Peter; Chattopadhyay, Goutam; Cwik, Thomas; Rowell, Mark; Hacker, John

    2009-01-01

    The term submillimeter confocal imaging active module (SCIAM) denotes a proposed airborne coherent imaging radar system that would be suitable for use in reconnaissance, surveillance, and navigation. The development of the SCIAM would include utilization and extension of recent achievements in monolithic microwave integrated circuits capable of operating at frequencies up to and beyond a nominal radio frequency of 340 GHz. Because the SCIAM would be primarily down-looking (in contradistinction to primarily side-looking), it could be useful for imaging shorter objects located between taller ones (for example, objects on streets between buildings). The SCIAM would utilize a confocal geometry to obtain high cross-track resolution, and would be amenable to synthetic-aperture processing of its output to obtain high along-track resolution. The SCIAM (see figure) would include multiple (two in the initial version) antenna apertures, separated from each other by a cross-track baseline of suitable length (e.g., 1.6 m). These apertures would both transmit the illuminating radar pulses and receive the returns. A common reference oscillator would generate a signal at a controllable frequency of (340 GHz + (Delta)f)/N, where (Delta)f is an instantaneous swept frequency difference and N is an integer. The output of this oscillator would be fed to a frequency- multiplier-and-power-amplifier module to obtain a signal, at 340 GHz + (Delta)f, that would serve as both the carrier signal for generating the transmitted pulses and a local-oscillator (LO) signal for a receiver associated with each antenna aperture. Because duplexers in the form of circulators or transmit/receive (T/R) switches would be lossy and extremely difficult to implement, the antenna apertures would be designed according to a spatial-diplexing scheme, in which signals would be coupled in and out via separate, adjacent transmitting and receiving feed horns. This scheme would cause the transmitted and received beams

  13. See around the corner using active imaging

    NASA Astrophysics Data System (ADS)

    Steinvall, Ove; Elmqvist, Magnus; Larsson, Håkan

    2011-11-01

    This paper investigates the prospects of "seeing around the corner" using active imaging. A monostatic active imaging system offers interesting capabilities in the presence of glossy reflecting objects. Examples of such surfaces are windows in buildings and cars, calm water, signs and vehicle surfaces. During daylight it might well be possible to use mirrorlike reflection by the naked eye or a CCD camera for non-line of sight imaging. However the advantage with active imaging is that one controls the illumination. This will not only allow for low light and night utilization but also for use in cases where the sun or other interfering lights limit the non-line of sight imaging possibility. The range resolution obtained by time gating will reduce disturbing direct reflections and allow simultaneous view in several directions using range discrimination. Measurements and theoretical considerations in this report support the idea of using laser to "see around the corner". Examples of images and reflectivity measurements will be presented together with examples of potential system applications.

  14. Generating passive NIR images from active LIDAR

    NASA Astrophysics Data System (ADS)

    Hagstrom, Shea; Broadwater, Joshua

    2016-05-01

    Many modern LIDAR platforms contain an integrated RGB camera for capturing contextual imagery. However, these RGB cameras do not collect a near-infrared (NIR) color channel, omitting information useful for many analytical purposes. This raises the question of whether LIDAR data, collected in the NIR, can be used as a substitute for an actual NIR image in this situation. Generating a LIDAR-based NIR image is potentially useful in situations where another source of NIR, such as satellite imagery, is not available. LIDAR is an active sensing system that operates very differently from a passive system, and thus requires additional processing and calibration to approximate the output of a passive instrument. We examine methods of approximating passive NIR images from LIDAR for real-world datasets, and assess differences with true NIR images.

  15. Active index for content-based medical image retrieval.

    PubMed

    Chang, S K

    1996-01-01

    This paper introduces the active index for content-based medical image retrieval. The dynamic nature of the active index is its most important characteristic. With an active index, we can effectively and efficiently handle smart images that respond to accessing, probing and other actions. The main applications of the active index are to prefetch image and multimedia data, and to facilitate similarity retrieval. The experimental active index system is described. PMID:8954230

  16. Active index for content-based medical image retrieval.

    PubMed

    Chang, S K

    1996-01-01

    This paper introduces the active index for content-based medical image retrieval. The dynamic nature of the active index is its most important characteristic. With an active index, we can effectively and efficiently handle smart images that respond to accessing, probing and other actions. The main applications of the active index are to prefetch image and multimedia data, and to facilitate similarity retrieval. The experimental active index system is described.

  17. Active-imaging-based underwater navigation

    NASA Astrophysics Data System (ADS)

    Monnin, David; Schmitt, Gwenaël.; Fischer, Colin; Laurenzis, Martin; Christnacher, Frank

    2015-10-01

    Global navigation satellite systems (GNSS) are widely used for the localization and the navigation of unmanned and remotely operated vehicles (ROV). In contrast to ground or aerial vehicles, GNSS cannot be employed for autonomous underwater vehicles (AUV) without the use of a communication link to the water surface, since satellite signals cannot be received underwater. However, underwater autonomous navigation is still possible using self-localization methods which determines the relative location of an AUV with respect to a reference location using inertial measurement units (IMU), depth sensors and even sometimes radar or sonar imaging. As an alternative or a complementary solution to common underwater reckoning techniques, we present the first results of a feasibility study of an active-imaging-based localization method which uses a range-gated active-imaging system and can yield radiometric and odometric information even in turbid water.

  18. Nuclear medicine imaging system

    DOEpatents

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J.; Rowe, R. Wanda; Zubal, I. George

    1986-01-07

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  19. Nuclear medicine imaging system

    DOEpatents

    Bennett, Gerald W.; Brill, A. Bertrand; Bizais, Yves J. C.; Rowe, R. Wanda; Zubal, I. George

    1986-01-01

    A nuclear medicine imaging system having two large field of view scintillation cameras mounted on a rotatable gantry and being movable diametrically toward or away from each other is disclosed. In addition, each camera may be rotated about an axis perpendicular to the diameter of the gantry. The movement of the cameras allows the system to be used for a variety of studies, including positron annihilation, and conventional single photon emission, as well as static orthogonal dual multi-pinhole tomography. In orthogonal dual multi-pinhole tomography, each camera is fitted with a seven pinhole collimator to provide seven views from slightly different perspectives. By using two cameras at an angle to each other, improved sensitivity and depth resolution is achieved. The computer system and interface acquires and stores a broad range of information in list mode, including patient physiological data, energy data over the full range detected by the cameras, and the camera position. The list mode acquisition permits the study of attenuation as a result of Compton scatter, as well as studies involving the isolation and correlation of energy with a range of physiological conditions.

  20. Active gated imaging for automotive safety applications

    NASA Astrophysics Data System (ADS)

    Grauer, Yoav; Sonn, Ezri

    2015-03-01

    The paper presents the Active Gated Imaging System (AGIS), in relation to the automotive field. AGIS is based on a fast gated-camera equipped with a unique Gated-CMOS sensor, and a pulsed Illuminator, synchronized in the time domain to record images of a certain range of interest which are then processed by computer vision real-time algorithms. In recent years we have learned the system parameters which are most beneficial to night-time driving in terms of; field of view, illumination profile, resolution and processing power. AGIS provides also day-time imaging with additional capabilities, which enhances computer vision safety applications. AGIS provides an excellent candidate for camera-based Advanced Driver Assistance Systems (ADAS) and the path for autonomous driving, in the future, based on its outstanding low/high light-level, harsh weather conditions capabilities and 3D potential growth capabilities.

  1. Scalable histopathological image analysis via active learning.

    PubMed

    Zhu, Yan; Zhang, Shaoting; Liu, Wei; Metaxas, Dimitris N

    2014-01-01

    Training an effective and scalable system for medical image analysis usually requires a large amount of labeled data, which incurs a tremendous annotation burden for pathologists. Recent progress in active learning can alleviate this issue, leading to a great reduction on the labeling cost without sacrificing the predicting accuracy too much. However, most existing active learning methods disregard the "structured information" that may exist in medical images (e.g., data from individual patients), and make a simplifying assumption that unlabeled data is independently and identically distributed. Both may not be suitable for real-world medical images. In this paper, we propose a novel batch-mode active learning method which explores and leverages such structured information in annotations of medical images to enforce diversity among the selected data, therefore maximizing the information gain. We formulate the active learning problem as an adaptive submodular function maximization problem subject to a partition matroid constraint, and further present an efficient greedy algorithm to achieve a good solution with a theoretically proven bound. We demonstrate the efficacy of our algorithm on thousands of histopathological images of breast microscopic tissues. PMID:25320821

  2. IMAGE ANALYSIS ALGORITHMS FOR DUAL MODE IMAGING SYSTEMS

    SciTech Connect

    Robinson, Sean M.; Jarman, Kenneth D.; Miller, Erin A.; Misner, Alex C.; Myjak, Mitchell J.; Pitts, W. Karl; Seifert, Allen; Seifert, Carolyn E.; Woodring, Mitchell L.

    2010-06-11

    The level of detail discernable in imaging techniques has generally excluded them from consideration as verification tools in inspection regimes where information barriers are mandatory. However, if a balance can be struck between sufficient information barriers and feature extraction to verify or identify objects of interest, imaging may significantly advance verification efforts. This paper describes the development of combined active (conventional) radiography and passive (auto) radiography techniques for imaging sensitive items assuming that comparison images cannot be furnished. Three image analysis algorithms are presented, each of which reduces full image information to non-sensitive feature information and ultimately is intended to provide only a yes/no response verifying features present in the image. These algorithms are evaluated on both their technical performance in image analysis and their application with or without an explicitly constructed information barrier. The first algorithm reduces images to non-invertible pixel intensity histograms, retaining only summary information about the image that can be used in template comparisons. This one-way transform is sufficient to discriminate between different image structures (in terms of area and density) without revealing unnecessary specificity. The second algorithm estimates the attenuation cross-section of objects of known shape based on transition characteristics around the edge of the object’s image. The third algorithm compares the radiography image with the passive image to discriminate dense, radioactive material from point sources or inactive dense material. By comparing two images and reporting only a single statistic from the combination thereof, this algorithm can operate entirely behind an information barrier stage. Together with knowledge of the radiography system, the use of these algorithms in combination can be used to improve verification capability to inspection regimes and improve

  3. OSPACS: Ultrasound image management system

    PubMed Central

    Stott, Will; Ryan, Andy; Jacobs, Ian J; Menon, Usha; Bessant, Conrad; Jones, Christopher

    2008-01-01

    Background Ultrasound scanning uses the medical imaging format, DICOM, for electronically storing the images and data associated with a particular scan. Large health care facilities typically use a picture archiving and communication system (PACS) for storing and retrieving such images. However, these systems are usually not suitable for managing large collections of anonymized ultrasound images gathered during a clinical screening trial. Results We have developed a system enabling the accurate archiving and management of ultrasound images gathered during a clinical screening trial. It is based upon a Windows application utilizing an open-source DICOM image viewer and a relational database. The system automates the bulk import of DICOM files from removable media by cross-validating the patient information against an external database, anonymizing the data as well as the image, and then storing the contents of the file as a field in a database record. These image records may then be retrieved from the database and presented in a tree-view control so that the user can select particular images for display in a DICOM viewer or export them to external media. Conclusion This system provides error-free automation of ultrasound image archiving and management, suitable for use in a clinical trial. An open-source project has been established to promote continued development of the system. PMID:18570637

  4. X-Ray Imaging System

    NASA Astrophysics Data System (ADS)

    1986-01-01

    The FluoroScan Imaging System is a high resolution, low radiation device for viewing stationary or moving objects. It resulted from NASA technology developed for x-ray astronomy and Goddard application to a low intensity x-ray imaging scope. FlouroScan Imaging Systems, Inc, (formerly HealthMate, Inc.), a NASA licensee, further refined the FluoroScan System. It is used for examining fractures, placement of catheters, and in veterinary medicine. Its major components include an x-ray generator, scintillator, visible light image intensifier and video display. It is small, light and maneuverable.

  5. A Systematical Method to Search for Active Solar System Objects from the Pan-STARRS Postage Stamp Images

    NASA Astrophysics Data System (ADS)

    Cheng, Yu-Chi; Wing, Wing-Huen; Hsieh, Henry; Lin, Hsing-Wen

    2015-04-01

    The outgassing effect and dust coma formation process can provide important information on the composition of a comet. The observational study of cometary activity at large heliocentric distance is particularly valuable from this point of view (Epifani et al., 2009; Meech et al., 2009; Kelly et al., 2013). Since mid-2009 the Pan-STARRS project with a wide-field 1.8-m telescope has provided continuous all-sky 3-π survey of time variable phenomena. The data archive is an excellent source for the study of outgassing activities of comets as they orbited around the Sun. We have evaluated the level of gas emission rates of Jupiter Family Comets (JFCs) at different heliocentric distanced by examining the corresponding point-spread function profiles in the postage stamp images. In total, the time evolutionary history of the dust comas of 300 comets has been investigated in terms of the Afρ parameter. In the present work, we will report on the interesting finding that many JFCs exhibited coma activities at heliocentric distance beyond the snow line of about 2.5 AU outside which water ice sublimation will become negligible. Moreover, some comets were active even close to Jupiter's orbit. Four classes of Afρ variability can be identified: (1) activity around perihelion as expected of water sublimation process; (2) presence of coma activity independent of heliocentric distance; (3) point source like nucleus; and (4) no detection. Examples of these different coma behaviors will be described. In addition. Highlights will be given to the detection of outburst-like events near aphelion.

  6. High speed imaging television system

    DOEpatents

    Wilkinson, William O.; Rabenhorst, David W.

    1984-01-01

    A television system for observing an event which provides a composite video output comprising the serially interlaced images the system is greater than the time resolution of any of the individual cameras.

  7. Backscatter absorption gas imaging system

    DOEpatents

    McRae, T.G. Jr.

    A video imaging system for detecting hazardous gas leaks. Visual displays of invisible gas clouds are produced by radiation augmentation of the field of view of an imaging device by radiation corresponding to an absorption line of the gas to be detected. The field of view of an imager is irradiated by a laser. The imager receives both backscattered laser light and background radiation. When a detectable gas is present, the backscattered laser light is highly attenuated, producing a region of contrast or shadow on the image. A flying spot imaging system is utilized to synchronously irradiate and scan the area to lower laser power requirements. The imager signal is processed to produce a video display.

  8. Backscatter absorption gas imaging system

    DOEpatents

    McRae, Jr., Thomas G.

    1985-01-01

    A video imaging system for detecting hazardous gas leaks. Visual displays of invisible gas clouds are produced by radiation augmentation of the field of view of an imaging device by radiation corresponding to an absorption line of the gas to be detected. The field of view of an imager is irradiated by a laser. The imager receives both backscattered laser light and background radiation. When a detectable gas is present, the backscattered laser light is highly attenuated, producing a region of contrast or shadow on the image. A flying spot imaging system is utilized to synchronously irradiate and scan the area to lower laser power requirements. The imager signal is processed to produce a video display.

  9. Active and interactive floating image display using holographic 3D images

    NASA Astrophysics Data System (ADS)

    Morii, Tsutomu; Sakamoto, Kunio

    2006-08-01

    We developed a prototype tabletop holographic display system. This system consists of the object recognition system and the spatial imaging system. In this paper, we describe the recognition system using an RFID tag and the 3D display system using a holographic technology. A 3D display system is useful technology for virtual reality, mixed reality and augmented reality. We have researched spatial imaging and interaction system. We have ever proposed 3D displays using the slit as a parallax barrier, the lenticular screen and the holographic optical elements(HOEs) for displaying active image 1,2,3. The purpose of this paper is to propose the interactive system using these 3D imaging technologies. In this paper, the authors describe the interactive tabletop 3D display system. The observer can view virtual images when the user puts the special object on the display table. The key technologies of this system are the object recognition system and the spatial imaging display.

  10. Images of an Activated Asteroid

    NASA Astrophysics Data System (ADS)

    Kohler, Susanna

    2016-08-01

    In late April of this year, asteroid P/2016 G1 (PANSTARRS) was discovered streaking through space, a tail of dust extending behind it. What caused this asteroids dust activity?Asteroid or Comet?Images of asteroid P/2016 G1 at three different times: late April, late May, and mid June. The arrow in the center panel points out an asymmetric feature that can be explained if the asteroid initially ejected material in a single direction, perhaps due to an impact. [Moreno et al. 2016]Asteroid P/2016 G1 is an interesting case: though it has the orbital elements of a main-belt asteroid it orbits at just under three times the EarthSun distance, with an eccentricity of e ~ 0.21 its appearance is closer to that of a comet, with a dust tail extending 20 behind it.To better understand the nature and cause of this unusual asteroids activity, a team led by Fernando Moreno (Institute of Astrophysics of Andalusia, in Spain) performed deep observations of P/2016 G1 shortly after its discovery. The team used the 10.4-meter Great Canary Telescope to image the asteroid over the span of roughly a month and a half.A Closer Look at P/2016 G1P/2016 G1 lies in the inner region of the main asteroid belt, so it is unlikely to have any ices that suddenly sublimated, causing the outburst. Instead, Moreno and collaborators suggest that the asteroids tail may have been caused by an impact that disrupted the parent body.To test this idea, the team used computer simulations to model their observations of P/2016 G1s dust tail. Based on their models, they demonstrate that the asteroid was likely activated on February 10 2016 roughly 350 days before it reached perihelion in its orbit and its activity was a short-duration event, lasting only ~24 days. The teams models indicate that over these 24 days, the asteroid lost around 20 million kilograms of dust, and at its maximum activity level, it was ejecting around 8 kg/s!Comparison of the observation from late May (panel a) and two models: one in which

  11. A novel injectable BRET-based in vivo imaging probe for detecting the activity of hypoxia-inducible factor regulated by the ubiquitin-proteasome system

    PubMed Central

    Kuchimaru, Takahiro; Suka, Tomoya; Hirota, Keisuke; Kadonosono, Tetsuya; Kizaka-Kondoh, Shinae

    2016-01-01

    The ubiquitin-proteasome system (UPS) is a selective protein degradation system that plays a critical role in many essential biological processes by regulating the existence of various cellular proteins. The target proteins of UPS are recognized and tagged with polyubiquitin chains by E3 ubiquitin ligases, which have high substrate-specific activities. Here we present a novel injectable imaging probe POL-N that can detect the UPS-regulated hypoxia-inducible factor (HIF) activity in vivo. Because the luciferase is fused to the E3 ligase-recognition domain of the HIF-1α, POL-N is intact only in the HIFα-overexpressing cells, that is, HIF-active cells, generating signals via an intramolecular bioluminescence resonance energy transfer (BRET) between luciferase and a near-infrared (NIR) fluorescent dye at the C-terminal end of the probe. Off-target signals of the NIR-BRET were so low that we could achieve highly sensitive and fast detection of intratumoral HIF-activity. Notably, we successfully detected hypoxic liver metastasis, which is extremely difficult to detect by injectable imaging probes due to strong off-target signals, as early as 1 h after systemic injection of POL-N. Our probe design can be widely adapted to UPS-target proteins and may contribute to the exploration of their roles in animal disease models. PMID:27698477

  12. Venus Aerobot Surface Science Imaging System (VASSIS)

    NASA Technical Reports Server (NTRS)

    Greeley, Ronald

    1999-01-01

    The VASSIS task was to design and develop an imaging system and container for operation above the surface of Venus in preparation for a Discovery-class mission involving a Venus aerobot balloon. The technical goals of the effort were to: a) evaluate the possible nadir-viewed surface image quality as a function of wavelength and altitude in the Venus lower atmosphere, b) design a pressure vessel to contain the imager and supporting electronics that will meet the environmental requirements of the VASSIS mission, c) design and build a prototype imaging system including an Active-Pixel Sensor camera head and VASSIS-like optics that will meet the science requirements. The VASSIS science team developed a set of science requirements for the imaging system upon which the development work of this task was based.

  13. X-Ray Imaging System

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The Model 60007A InnerView Real-time X-ray Imaging System, produced by National Imaging Systems, a division of FlouroScan Imaging Systems, Inc. (formerly HealthMate, Inc.), Northbrook, IL, is a third generation spinoff from x-ray astronomy technology. Goddard Space Flight Center developed the original technology into the Lixiscope, a small, portable, minimal radiation x-ray instrument that could be used at the scene of an accident. FlouroScan Imaging Systems, Inc., adapted this technology to develop the FlouroScan, a low-intensity, x-ray system that could be used without the lead aprons, film badges and lead-lined walls that conventional systems require. The InnerView is a spinoff of non-destructive testing and product inspection.

  14. A hybrid continuous-wave terahertz imaging system

    SciTech Connect

    Dolganova, Irina N. Zaytsev, Kirill I. Metelkina, Anna A.; Karasik, Valeriy E.; Yurchenko, Stanislav O.

    2015-11-15

    A hybrid (active-passive mode) terahertz (THz) imaging system and an algorithm for imaging synthesis are proposed to enhance the THz image quality. The concept of image contrast is used to compare active and passive THz imaging. Combining the measurement of the self-emitted radiation of the object with the back-scattered source radiation measurement, it becomes possible to use the THz image to retrieve maximum information about the object. The experimental results confirm the advantages of hybrid THz imaging systems, which can be generalized for a wide range of applications in the material sciences, chemical physics, bio-systems, etc.

  15. Underwater laser imaging system (UWLIS)

    SciTech Connect

    DeLong, M.

    1994-11-15

    Practical limitations with underwater imaging systems area reached when the noise in the back scattered radiation generated in the water between the imaging system and the target obscures the spatial contrast and resolution necessary for target discovery and identification. The advent of high power lasers operating in the blue-green portion of the visible spectrum (oceanic transmission window) has led to improved experimental illumination systems for underwater imaging. Range-gated and synchronously scanned devices take advantage of the unique temporal and spatial coherence properties of laser radiation, respectively, to overcome the deleterious effects of common volume back scatter.

  16. Advanced Land Imager Assessment System

    NASA Technical Reports Server (NTRS)

    Chander, Gyanesh; Choate, Mike; Christopherson, Jon; Hollaren, Doug; Morfitt, Ron; Nelson, Jim; Nelson, Shar; Storey, James; Helder, Dennis; Ruggles, Tim; Kaita, Ed; Levy, Raviv; Ong, Lawrence; Markham, Brian; Schweiss, Robert

    2008-01-01

    The Advanced Land Imager Assessment System (ALIAS) supports radiometric and geometric image processing for the Advanced Land Imager (ALI) instrument onboard NASA s Earth Observing-1 (EO-1) satellite. ALIAS consists of two processing subsystems for radiometric and geometric processing of the ALI s multispectral imagery. The radiometric processing subsystem characterizes and corrects, where possible, radiometric qualities including: coherent, impulse; and random noise; signal-to-noise ratios (SNRs); detector operability; gain; bias; saturation levels; striping and banding; and the stability of detector performance. The geometric processing subsystem and analysis capabilities support sensor alignment calibrations, sensor chip assembly (SCA)-to-SCA alignments and band-to-band alignment; and perform geodetic accuracy assessments, modulation transfer function (MTF) characterizations, and image-to-image characterizations. ALIAS also characterizes and corrects band-toband registration, and performs systematic precision and terrain correction of ALI images. This system can geometrically correct, and automatically mosaic, the SCA image strips into a seamless, map-projected image. This system provides a large database, which enables bulk trending for all ALI image data and significant instrument telemetry. Bulk trending consists of two functions: Housekeeping Processing and Bulk Radiometric Processing. The Housekeeping function pulls telemetry and temperature information from the instrument housekeeping files and writes this information to a database for trending. The Bulk Radiometric Processing function writes statistical information from the dark data acquired before and after the Earth imagery and the lamp data to the database for trending. This allows for multi-scene statistical analyses.

  17. Multilingual system using Internet imaging

    NASA Astrophysics Data System (ADS)

    Mori, Tadashi; Hata, Yoshitsugu; Iida, Ryouji; Kakugawa, Hirotsugu; Ae, Tadashi; Murakami, Hisae

    2000-12-01

    In these years, multilingual system becomes important, but, most computer environment cannot handle all languages (scripts) in ths world. This paper presents a multilingual imaging system on the Internet. In this system, characters are converted into bitmaps, and therefore, we can display multilingual text on WWW browsers. In order to convert multilingual plain text into bitmap images, we have developed software named ctext2pgm and VFlib. VFlib is a software component to rasterize fonts in various file formats, and ctext2pgm generates bitmap image files form multilingual plain texts. Ctext2pgm is an application program of VFlib, and it supports about 30 languages. We also introduce a language education system for various languages. This is an example of the multilingual system using internet imaging.

  18. EDITORIAL: Imaging Systems and Techniques Imaging Systems and Techniques

    NASA Astrophysics Data System (ADS)

    Giakos, George; Yang, Wuqiang; Petrou, M.; Nikita, K. S.; Pastorino, M.; Amanatiadis, A.; Zentai, G.

    2011-10-01

    This special feature on Imaging Systems and Techniques comprises 27 technical papers, covering essential facets in imaging systems and techniques both in theory and applications, from research groups spanning three different continents. It mainly contains peer-reviewed articles from the IEEE International Conference on Imaging Systems and Techniques (IST 2011), held in Thessaloniki, Greece, as well a number of articles relevant to the scope of this issue. The multifaceted field of imaging requires drastic adaptation to the rapid changes in our society, economy, environment, and the technological revolution; there is an urgent need to address and propose dynamic and innovative solutions to problems that tend to be either complex and static or rapidly evolving with a lot of unknowns. For instance, exploration of the engineering and physical principles of new imaging systems and techniques for medical applications, remote sensing, monitoring of space resources and enhanced awareness, exploration and management of natural resources, and environmental monitoring, are some of the areas that need to be addressed with urgency. Similarly, the development of efficient medical imaging techniques capable of providing physiological information at the molecular level is another important area of research. Advanced metabolic and functional imaging techniques, operating on multiple physical principles, using high resolution and high selectivity nanoimaging techniques, can play an important role in the diagnosis and treatment of cancer, as well as provide efficient drug-delivery imaging solutions for disease treatment with increased sensitivity and specificity. On the other hand, technical advances in the development of efficient digital imaging systems and techniques and tomographic devices operating on electric impedance tomography, computed tomography, single-photon emission and positron emission tomography detection principles are anticipated to have a significant impact on a

  19. Airborne Hyperspectral Imaging System

    NASA Technical Reports Server (NTRS)

    Behar, Alberto E.; Cooper, Moogega; Adler, John; Jacobson, Tobias

    2012-01-01

    A document discusses a hyperspectral imaging instrument package designed to be carried aboard a helicopter. It was developed to map the depths of Greenland's supraglacial lakes. The instrument is capable of telescoping to twice its original length, allowing it to be retracted with the door closed during takeoff and landing, and manually extended in mid-flight. While extended, the instrument platform provides the attached hyperspectral imager a nadir-centered and unobstructed view of the ground. Before flight, the instrument mount is retracted and securely strapped down to existing anchor points on the floor of the helicopter. When the helicopter reaches the destination lake, the door is opened and the instrument mount is manually extended. Power to the instrument package is turned on, and the data acquisition computer is commanded via a serial cable from an onboard user-operated laptop to begin data collection. After data collection is complete, the instrument package is powered down and the mount retracted, allowing the door to be closed in preparation for landing. The present design for the instrument mount consists of a three-segment telescoping cantilever to allow for a sufficient extended length to see around the landing struts and provide a nadir-centered and unobstructed field of view for the hyperspectral imager. This instrument works on the premise that water preferentially absorbs light with longer wavelengths on the red side of the visible spectrum. This property can be exploited in order to remotely determine the depths of bodies of pure freshwater. An imager flying over such a lake receives light scattered from the surface, the bulk of the water column, and from the lake bottom. The strength of absorption of longer-wavelength light depends on the depth of the water column. Through calibration with in situ measurements of the water depths, a depth-determining algorithm may be developed to determine lake depth from these spectral properties of the

  20. Hinode Captures Images of Solar Active Region

    NASA Video Gallery

    In these images, Hinode's Solar Optical Telescope (SOT) zoomed in on AR 11263 on August 4, 2011, five days before the active region produced the largest flare of this cycle, an X6.9. We show images...

  1. Stereoscopic medical imaging collaboration system

    NASA Astrophysics Data System (ADS)

    Okuyama, Fumio; Hirano, Takenori; Nakabayasi, Yuusuke; Minoura, Hirohito; Tsuruoka, Shinji

    2007-02-01

    The computerization of the clinical record and the realization of the multimedia have brought improvement of the medical service in medical facilities. It is very important for the patients to obtain comprehensible informed consent. Therefore, the doctor should plainly explain the purpose and the content of the diagnoses and treatments for the patient. We propose and design a Telemedicine Imaging Collaboration System which presents a three dimensional medical image as X-ray CT, MRI with stereoscopic image by using virtual common information space and operating the image from a remote location. This system is composed of two personal computers, two 15 inches stereoscopic parallax barrier type LCD display (LL-151D, Sharp), one 1Gbps router and 1000base LAN cables. The software is composed of a DICOM format data transfer program, an operation program of the images, the communication program between two personal computers and a real time rendering program. Two identical images of 512×768 pixcels are displayed on two stereoscopic LCD display, and both images show an expansion, reduction by mouse operation. This system can offer a comprehensible three-dimensional image of the diseased part. Therefore, the doctor and the patient can easily understand it, depending on their needs.

  2. Optical Imaging of Neuronal Activity and Visualization of Fine Neural Structures in Non-Desheathed Nervous Systems

    PubMed Central

    Stein, Wolfgang

    2014-01-01

    Locating circuit neurons and recording from them with single-cell resolution is a prerequisite for studying neural circuits. Determining neuron location can be challenging even in small nervous systems because neurons are densely packed, found in different layers, and are often covered by ganglion and nerve sheaths that impede access for recording electrodes and neuronal markers. We revisited the voltage-sensitive dye RH795 for its ability to stain and record neurons through the ganglion sheath. Bath-application of RH795 stained neuronal membranes in cricket, earthworm and crab ganglia without removing the ganglion sheath, revealing neuron cell body locations in different ganglion layers. Using the pyloric and gastric mill central pattern generating neurons in the stomatogastric ganglion (STG) of the crab, Cancer borealis, we found that RH795 permeated the ganglion without major residue in the sheath and brightly stained somatic, axonal and dendritic membranes. Visibility improved significantly in comparison to unstained ganglia, allowing the identification of somata location and number of most STG neurons. RH795 also stained axons and varicosities in non-desheathed nerves, and it revealed the location of sensory cell bodies in peripheral nerves. Importantly, the spike activity of the sensory neuron AGR, which influences the STG motor patterns, remained unaffected by RH795, while desheathing caused significant changes in AGR activity. With respect to recording neural activity, RH795 allowed us to optically record membrane potential changes of sub-sheath neuronal membranes without impairing sensory activity. The signal-to-noise ratio was comparable with that previously observed in desheathed preparations and sufficiently high to identify neurons in single-sweep recordings and synaptic events after spike-triggered averaging. In conclusion, RH795 enabled staining and optical recording of neurons through the ganglion sheath and is therefore both a good anatomical

  3. Hyperspectral Systems Increase Imaging Capabilities

    NASA Technical Reports Server (NTRS)

    2010-01-01

    In 1983, NASA started developing hyperspectral systems to image in the ultraviolet and infrared wavelengths. In 2001, the first on-orbit hyperspectral imager, Hyperion, was launched aboard the Earth Observing-1 spacecraft. Based on the hyperspectral imaging sensors used in Earth observation satellites, Stennis Space Center engineers and Institute for Technology Development researchers collaborated on a new design that was smaller and used an improved scanner. Featured in Spinoff 2007, the technology is now exclusively licensed by Themis Vision Systems LLC, of Richmond, Virginia, and is widely used in medical and life sciences, defense and security, forensics, and microscopy.

  4. Image-based retrieval system and computer-aided diagnosis system for renal cortical scintigraphy images

    NASA Astrophysics Data System (ADS)

    Mumcuoğlu, Erkan; Nar, Fatih; Uğur, Omer; Bozkurt, M. Fani; Aslan, Mehmet

    2008-03-01

    Cortical renal (kidney) scintigraphy images are 2D images (256x256) acquired in three projection angles (posterior, right-posterior-oblique and left-posterior-oblique). These images are used by nuclear medicine specialists to examine the functional morphology of kidney parenchyma. The main visual features examined in reading the images are: size, location, shape and activity distribution (pixel intensity distribution within the boundary of each kidney). Among the above features, activity distribution (in finding scars if any) was found to have the least interobserver reproducibility. Therefore, in this study, we developed an image-based retrieval (IBR) and a computer-based diagnosis (CAD) system, focused on this feature in particular. The developed IBR and CAD algorithms start with automatic segmentation, boundary and landmark detection. Then, shape and activity distribution features are computed. Activity distribution feature is obtained using the acquired image and image set statistics of the normal patients. Active Shape Model (ASM) technique is used for more accurate kidney segmentation. In the training step of ASM, normal patient images are used. Retrieval performance is evaluated by calculating precision and recall. CAD performance is evaluated by specificity and sensitivity. To our knowledge, this paper is the first IBR or CAD system reported in the literature on renal cortical scintigraphy images.

  5. Self-adaptive iris image acquisition system

    NASA Astrophysics Data System (ADS)

    Dong, Wenbo; Sun, Zhenan; Tan, Tieniu; Qiu, Xianchao

    2008-03-01

    Iris image acquisition is the fundamental step of the iris recognition, but capturing high-resolution iris images in real-time is very difficult. The most common systems have small capture volume and demand users to fully cooperate with machines, which has become the bottleneck of iris recognition's application. In this paper, we aim at building an active iris image acquiring system which is self-adaptive to users. Two low resolution cameras are co-located in a pan-tilt-unit (PTU), for face and iris image acquisition respectively. Once the face camera detects face region in real-time video, the system controls the PTU to move towards the eye region and automatically zooms, until the iris camera captures an clear iris image for recognition. Compared with other similar works, our contribution is that we use low-resolution cameras, which can transmit image data much faster and are much cheaper than the high-resolution cameras. In the system, we use Haar-like cascaded feature to detect faces and eyes, linear transformation to predict the iris camera's position, and simple heuristic PTU control method to track eyes. A prototype device has been established, and experiments show that our system can automatically capture high-quality iris image in the range of 0.6m×0.4m×0.4m in average 3 to 5 seconds.

  6. The Europa Imaging System (EIS), a Camera Suite to investigate Europa's Geology, Ice Shell, and Potential for Current Activity

    NASA Astrophysics Data System (ADS)

    Turtle, E. P.; McEwen, A. S.; Osterman, S. N.; Boldt, J. D.; Strohbehn, K.; EIS Science Team

    2016-10-01

    EIS NAC and WAC use identical rad-hard rapid-readout 4k × 2k CMOS detectors for imaging during close (≤25 km) fast ( 4.5 km/s) Europa flybys. NAC achieves 0.5 m/pixel over a 2-km swath from 50 km, and WAC provides context pushbroom stereo imaging.

  7. Natural image classification driven by human brain activity

    NASA Astrophysics Data System (ADS)

    Zhang, Dai; Peng, Hanyang; Wang, Jinqiao; Tang, Ming; Xue, Rong; Zuo, Zhentao

    2016-03-01

    Natural image classification has been a hot topic in computer vision and pattern recognition research field. Since the performance of an image classification system can be improved by feature selection, many image feature selection methods have been developed. However, the existing supervised feature selection methods are typically driven by the class label information that are identical for different samples from the same class, ignoring with-in class image variability and therefore degrading the feature selection performance. In this study, we propose a novel feature selection method, driven by human brain activity signals collected using fMRI technique when human subjects were viewing natural images of different categories. The fMRI signals associated with subjects viewing different images encode the human perception of natural images, and therefore may capture image variability within- and cross- categories. We then select image features with the guidance of fMRI signals from brain regions with active response to image viewing. Particularly, bag of words features based on GIST descriptor are extracted from natural images for classification, and a sparse regression base feature selection method is adapted to select image features that can best predict fMRI signals. Finally, a classification model is built on the select image features to classify images without fMRI signals. The validation experiments for classifying images from 4 categories of two subjects have demonstrated that our method could achieve much better classification performance than the classifiers built on image feature selected by traditional feature selection methods.

  8. A programmable image compression system

    NASA Technical Reports Server (NTRS)

    Farrelle, Paul M.

    1989-01-01

    A programmable image compression system which has the necessary flexibility to address diverse imaging needs is described. It can compress and expand single frame video images (monochrome or color) as well as documents and graphics (black and white or color) for archival or transmission applications. Through software control, the compression mode can be set for lossless or controlled quality coding; the image size and bit depth can be varied; and the image source and destination devices can be readily changed. Despite the large combination of image data types, image sources, and algorithms, the system provides a simple consistent interface to the programmer. This system (OPTIPAC) is based on the TITMS320C25 digital signal processing (DSP) chip and has been implemented as a co-processor board for an IBM PC-AT compatible computer. The underlying philosophy can readily be applied to different hardware platforms. By using multiple DSP chips or incorporating algorithm specific chips, the compression and expansion times can be significantly reduced to meet performance requirements.

  9. Variable addressability imaging systems

    NASA Astrophysics Data System (ADS)

    Kubala, Kenneth Scott

    The use of variable addressability for creating an optimum human-machine interface is investigated. Current wide field optical systems present more information to the human visual system than it has the capacity to perceive. The axial resolution, and/or the field of view can be increased by minimizing the difference between what the eye can perceive and what the system presents. The variable addressability function was developed through the use of a human factors experiment that characterized the position of the eye during the simulated use of a binocular system. Applying the variable addressability function to a conventional optical design required the development of a new metric for evaluating the expected performance of the variable addressability system. The new metric couples psycho-visual data and traditional optical data in order to specify the required performance of the variable addressability system. A non-linear mapping of the pixels is required in order to have the system work most efficiently with the human visual system, while also compensating for eye motion. The non-linear mapping function, which is the backbone of the variable addressability technique, can be created using optical distortion. The lens and system design is demonstrated in two different spectral bands. One of the designs was fabricated, tested, and assembled into a prototype. Through a second human factors study aimed at measuring performance, the variable addressability prototype was directly compared to a uniform addressability prototype, quantifying the difference in performance for the two prototypes. The human factors results showed that the variable addressability prototype provided better resolution 13% of the time throughout the experiment, but was 15% slower in use than the uniform addressability prototype.

  10. Novel optical system for neonatal brain imaging

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Zhou, Shuoming; Nioka, Shoko; Chance, Britton; Anday, Endla; Ravishankar, Sudha; Delivoria-Papadopoulos, Maria

    1999-03-01

    A highly portable, fast, safe and affordable imaging system that provides interpretable images of brain function in full- and pre-term neonates within a few seconds has been applied to neonates with normal and pathological states. We have used a uniquely sensitive optical tomography system, termed phased array, which has revealed significant functional responses, particularly to parietal stimulation in neonate brain. This system can indicate the blood concentration and oxygenation change during the parietal brain activation in full- and pre-term neonates. The preliminary clinical results, especially a longitudinal study of a cardiac arrest neonate, suggest a variety of future applications.

  11. Devices, systems, and methods for imaging

    DOEpatents

    Appleby, David; Fraser, Iain; Watson, Scott

    2008-04-15

    Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

  12. Limbic system (image)

    MedlinePlus

    ... structures which govern emotions and behavior. The limbic system, and in particular the hippocampus and amygdala, is involved in the formation of long-term memory, and is closely associated with the olfactory structures (having to do with the sense of ...

  13. Skin imaging in systemic sclerosis

    PubMed Central

    Kang, Taeyoung; Abignano, Giuseppina; Lettieri, Giovanni; Wakefield, Richard J.; Emery, Paul; Del Galdo, Francesco

    2014-01-01

    Fibrotic involvement of the skin is a cardinal feature of systemic sclerosis (SSc). The extent of skin involvement is associated with internal organ involvement, coinciding with more severe disease course and poor prognosis. A palpation-based semi-quantitative score, the modified Rodnan skin score, is widely used for the assessment of skin involvement, but it is entailed by significant limitations. More objective approaches to measure skin involvement employing imaging have been explored continuously in the past decades and are currently advancing. Here, we review the use of different imaging techniques for the assessment of skin involvement in patients with SSc, focusing mainly on ultrasound, magnetic resonance imaging, and optical coherence tomography.

  14. Hemodynamic responses to functional activation accessed by optical imaging

    NASA Astrophysics Data System (ADS)

    Ni, Songlin; Li, Pengcheng; Yang, Yuanyuan; Lv, Xiaohua; Luo, Qingming

    2006-01-01

    A multi-wavelength light-emitting diode (LED) and laser diode (LD) based optical imaging system was developed to visualize the changes in cerebral blood flow, oxygenation following functional activation simultaneously in rodent cortex. The 2-D blood flow image was accessed by laser speckle contrast imaging, and the spectroscopic imaging of intrinsic signal was used for the calculation of oxyhemoglobin (HbO), deoxyhemoglobin (Hb) and total hemoglobin (HbT) concentration. The combination of spectroscopic imaging and laser speckle contrast imaging provides the capability to simultaneously investigate the spatial and temporal blood flow and hemoglobin concentration changes with high resolution, which may lead to a better understanding of the coupling between neuronal activation and vascular responses. The optical imaging system been built is compact and convenient to investigators. And it is reliable to acquire raw data. In present study, the hemodynamic responses to cortical spreading depression (CSD) in parietal cortex of ~-chloralose/urethan anesthetized rats were demonstrated.

  15. Imaging Calcium in Drosophila at Egg Activation.

    PubMed

    Derrick, Christopher J; York-Andersen, Anna H; Weil, Timothy T

    2016-01-01

    Egg activation is a universal process that includes a series of events to allow the fertilized egg to complete meiosis and initiate embryonic development. One aspect of egg activation, conserved across all organisms examined, is a change in the intracellular concentration of calcium (Ca(2+)) often termed a 'Ca(2+) wave'. While the speed and number of oscillations of the Ca(2+) wave varies between species, the change in intracellular Ca(2+) is key in bringing about essential events for embryonic development. These changes include resumption of the cell cycle, mRNA regulation, cortical granule exocytosis, and rearrangement of the cytoskeleton. In the mature Drosophila egg, activation occurs in the female oviduct prior to fertilization, initiating a series of Ca(2+)-dependent events. Here we present a protocol for imaging the Ca(2+) wave in Drosophila. This approach provides a manipulable model system to interrogate the mechanism of the Ca(2+) wave and the downstream changes associated with it. PMID:27584955

  16. Underwater laser imaging system (UWLIS)

    SciTech Connect

    DeLong, M.L.; Kulp, T.J.

    1995-03-10

    Practical limitations of underwater imaging systems are reached when the noise in the back scattered radiation generated in the water between the imaging system and the target obscures the spatial contrast and the resolution necessary for target discovery and identification. The advent of high power lasers operating in the oceanic transmission window of the visible spectrum (blue-green portion) has led to improved experimental illumination systems for underwater imaging The properties of laser bearm in range-gated and synchronously scanned devices take advantage of the unique temporal and spatial coherence effect of common volume back scatter to reduce or eliminate noise, increase signal to noise levels. Synchronously scanned systems rely on the highly collimated nature of the laser beam for spatial rejection of common volume back scatter. A synchronous, raster-scanning underwater laser imaging system (UWLIS) has been developed at Lawrence liver-more National Laboratory. The present UWLIS system differs from earlier synchronous scanners in its ability to scan in two dimensions at conventional video frame rate (30 Hz). The imaging performance of the present UWLIS was measured at distances of up to 6.3 AL (at a physical distance of 15.2 meters) during an in-water tank test and 4.5 to 5.0 AL (at a physical distance of 30 meters) during open water oceanic testing. The test results indicate that the UWLIS system is already capable of extending the underwater imaging range beyond that of conventional floodlight illuminated SIT cameras. The real or near real time frame rates of the UWLIS make possible operations in a mode in which the platform speed is randomly varied. This is typical of the operational environment in which the platform is often maneuvered above and around rugged seafloor terrain`s and obstacles.

  17. Hyperspectral imaging system for UAV

    NASA Astrophysics Data System (ADS)

    Zhang, Da; Zheng, Yuquan

    2015-10-01

    Hyperspectral imaging system for Unmanned Aerial Vehicle (UAV) is proposed under airborne remote sensing application background. By the application of Offner convex spherical grating spectral imaging system and using large area array detector push-broom imaging, hyperspectral imaging system with the indicators of 0.4μm to 1.0μm spectral range, 120 spectral bands, 5nm spectral resolution and 1m ground sampling interval (flight altitude 5km) is developed and completed. The Offner convex grating spectral imaging system is selected to achieve non-spectral line bending and colorless distortion design results. The diffraction efficiency is 15%-30% in the range of 0.4μm to 1.0μm wavelength. The system performances are tested by taking spectral and radiometric calibration methods in the laboratory. Based on monochromatic collimated light method for spectral performance parameters calibration of hyperspectral optical remote sensor, the analysis results of spectral calibration data show that the calibration test repeatability is less than 0.2 nm within one hour. The spectral scaling results show that the average spectral resolution of hyperspectral optical remote sensor is 4.94 nm, and the spatial dimension of the high-spectral optical remote sensor spectral resolution is less than 5 nm, the average of the typical spectral bandwidth is about 6 nm, the system average signal-to-noise ratio (SNR) is up to 43dB under typical operating conditions. Finally the system functionalities and performance indicators are verified by the aviation flight tests, which it's equipped on UAV. The actual image quality is good, and the spectral position is stable.

  18. High-resolution ophthalmic imaging system

    DOEpatents

    Olivier, Scot S.; Carrano, Carmen J.

    2007-12-04

    A system for providing an improved resolution retina image comprising an imaging camera for capturing a retina image and a computer system operatively connected to the imaging camera, the computer producing short exposures of the retina image and providing speckle processing of the short exposures to provide the improved resolution retina image. The system comprises the steps of capturing a retina image, producing short exposures of the retina image, and speckle processing the short exposures of the retina image to provide the improved resolution retina image.

  19. Flyception: imaging brain activity in freely walking fruit flies.

    PubMed

    Grover, Dhruv; Katsuki, Takeo; Greenspan, Ralph J

    2016-07-01

    Genetically encoded calcium sensors have enabled monitoring of neural activity in vivo using optical imaging techniques. Linking neural activity to complex behavior remains challenging, however, as most imaging systems require tethering the animal, which can impact the animal's behavioral repertoire. Here, we report a method for monitoring the brain activity of untethered, freely walking Drosophila melanogaster during sensorially and socially evoked behaviors to facilitate the study of neural mechanisms that underlie naturalistic behaviors. PMID:27183441

  20. A compact THz imaging system

    NASA Astrophysics Data System (ADS)

    Sešek, Aleksander; Å vigelj, Andrej; Trontelj, Janez

    2015-03-01

    The objective of this paper is the development of a compact low cost imaging THz system, usable for observation of the objects near to the system and also for stand-off detection. The performance of the system remains at the high standard of more expensive and bulkiest system on the market. It is easy to operate as it is not dependent on any fine mechanical adjustments. As it is compact and it consumes low power, also a portable system was developed for stand-off detection of concealed objects under textile or inside packages. These requirements rule out all optical systems like Time Domain Spectroscopy systems which need fine optical component positioning and requires a large amount of time to perform a scan and the image capture pixel-by-pixel. They are also almost not suitable for stand-off detection due to low output power. In the paper the antenna - bolometer sensor microstructure is presented and the THz system described. Analysis and design guidelines for the bolometer itself are discussed. The measurement results for both near and stand-off THz imaging are also presented.

  1. Dynamic granularity of imaging systems

    DOE PAGES

    Geissel, Matthias; Smith, Ian C.; Shores, Jonathon E.; Porter, John L.

    2015-11-04

    Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” Gdyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rathermore » than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.« less

  2. Dynamic granularity of imaging systems

    SciTech Connect

    Geissel, Matthias; Smith, Ian C.; Shores, Jonathon E.; Porter, John L.

    2015-11-04

    Imaging systems that include a specific source, imaging concept, geometry, and detector have unique properties such as signal-to-noise ratio, dynamic range, spatial resolution, distortions, and contrast. Some of these properties are inherently connected, particularly dynamic range and spatial resolution. It must be emphasized that spatial resolution is not a single number but must be seen in the context of dynamic range and consequently is better described by a function or distribution. We introduce the “dynamic granularity” Gdyn as a standardized, objective relation between a detector’s spatial resolution (granularity) and dynamic range for complex imaging systems in a given environment rather than the widely found characterization of detectors such as cameras or films by themselves. We found that this relation can partly be explained through consideration of the signal’s photon statistics, background noise, and detector sensitivity, but a comprehensive description including some unpredictable data such as dust, damages, or an unknown spectral distribution will ultimately have to be based on measurements. Measured dynamic granularities can be objectively used to assess the limits of an imaging system’s performance including all contributing noise sources and to qualify the influence of alternative components within an imaging system. Our article explains the construction criteria to formulate a dynamic granularity and compares measured dynamic granularities for different detectors used in the X-ray backlighting scheme employed at Sandia’s Z-Backlighter facility.

  3. 3D Backscatter Imaging System

    NASA Technical Reports Server (NTRS)

    Turner, D. Clark (Inventor); Whitaker, Ross (Inventor)

    2016-01-01

    Systems and methods for imaging an object using backscattered radiation are described. The imaging system comprises both a radiation source for irradiating an object that is rotationally movable about the object, and a detector for detecting backscattered radiation from the object that can be disposed on substantially the same side of the object as the source and which can be rotationally movable about the object. The detector can be separated into multiple detector segments with each segment having a single line of sight projection through the object and so detects radiation along that line of sight. Thus, each detector segment can isolate the desired component of the backscattered radiation. By moving independently of each other about the object, the source and detector can collect multiple images of the object at different angles of rotation and generate a three dimensional reconstruction of the object. Other embodiments are described.

  4. Scanning Terahertz Heterodyne Imaging Systems

    NASA Technical Reports Server (NTRS)

    Siegel, Peter; Dengler, Robert

    2007-01-01

    Scanning terahertz heterodyne imaging systems are now at an early stage of development. In a basic scanning terahertz heterodyne imaging system, (see Figure 1) two far-infrared lasers generate beams denoted the local-oscillator (LO) and signal that differ in frequency by an amount, denoted the intermediate frequency (IF), chosen to suit the application. The LO beam is sent directly to a mixer as one of two inputs. The signal beam is focused to a spot on or in the specimen. After transmission through or reflection from the specimen, the beams are focused to a spot on a terahertz mixer, which extracts the IF outputs. The specimen is mounted on a translation stage, by means of which the focal spot is scanned across the specimen to build up an image.

  5. Implementation of a novel floating-image display system having a background of multiview integral images

    NASA Astrophysics Data System (ADS)

    Hong, Suk-Pyo; Oh, Yong-Seok; Shin, Dong-Hak; Kim, Eun-Soo

    2007-09-01

    A floating-image display technique, which can project two-dimensional images into a real space through a convex lens or a concave mirror, has been studied as a new approach for implementation of the next-generation three-dimensional (3D) display system. However, the conventional floating-image display system was implemented just by using active display devices such as LCD panel and it could provide only a real plane image in space to an observer comparing with other 3D display systems having different perspectives. For practical application of a floating-image display system to 3D display systems, multi-layered display structure might be required to present multi-depth images in space. In this paper, a novel floating-image display system composed of two plane images with different depth by use of a half mirror is proposed. One plane image of an object is provided with the conventional floating-image display system to present and the other plane image of a background is provided with the integral imaging technique. Therefore, the proposed display system can provide high-resolution floating images with background images having different perspectives to observers. To show the usefulness of the proposed system, some experiments are carried out and the results are presented as well.

  6. Compact Microscope Imaging System Developed

    NASA Technical Reports Server (NTRS)

    McDowell, Mark

    2001-01-01

    The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

  7. Video imaging systems: A survey

    NASA Astrophysics Data System (ADS)

    Kefauver, H. Lee

    1989-07-01

    Recent technological advances in the field of electronics have made video imaging a viable substitute for the traditional Polaroid(trademark) picture used to create photo ID credentials. New families of hardware and software products, when integrated into a system, provide an exciting and powerful toll which can be used simply to make badges or enhance an access control system. The reader is made aware of who is currently in this business and compare their capabilities.

  8. A computed tomographic imaging system for experimentation

    NASA Astrophysics Data System (ADS)

    Lu, Yanping; Wang, Jue; Liu, Fenglin; Yu, Honglin

    2008-03-01

    Computed tomography (CT) is a non-invasive imaging technique, which is widely applied in medicine for diagnosis and surgical planning, and in industry for non-destructive testing (NDT) and non-destructive evaluation (NDE). So, it is significant for college students to understand the fundamental of CT. In this work, A CT imaging system named CD-50BG with 50mm field-of-view has been developed for experimental teaching at colleges. With the translate-rotate scanning mode, the system makes use of a 7.4×10 8Bq (20mCi) activity 137Cs radioactive source which is held in a tungsten alloy to shield the radiation and guarantee no harm to human body, and a single plastic scintillator + photomultitude detector which is convenient for counting because of its short-time brightness and good single pulse. At same time, an image processing software with the functions of reconstruction, image processing and 3D visualization has also been developed to process the 16 bits acquired data. The reconstruction time for a 128×128 image is less than 0.1 second. High quality images with 0.8mm spatial resolution and 2% contrast sensitivity can be obtained. So far in China, more than ten institutions of higher education, including Tsinghua University and Peking University, have already applied the system for elementary teaching.

  9. Electronic imaging system and technique

    DOEpatents

    Bolstad, Jon O.

    1987-01-01

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  10. Electronic imaging system and technique

    DOEpatents

    Bolstad, J.O.

    1984-06-12

    A method and system for viewing objects obscurred by intense plasmas or flames (such as a welding arc) includes a pulsed light source to illuminate the object, the peak brightness of the light reflected from the object being greater than the brightness of the intense plasma or flame; an electronic image sensor for detecting a pulsed image of the illuminated object, the sensor being operated as a high-speed shutter; and electronic means for synchronizing the shutter operation with the pulsed light source.

  11. Physical activity - preventive medicine (image)

    MedlinePlus

    Physical activity contributes to health by reducing the heart rate, decreasing the risk for cardiovascular disease, and reducing ... loss that is associated with age and osteoporosis. Physical activity also helps the body use calories more efficiently, ...

  12. Enhanced integral imaging system using image floating technique

    NASA Astrophysics Data System (ADS)

    Min, Sung-Wook; Kim, Joohwan; Lee, Byoungho

    2005-09-01

    Enhanced integral imaging system based on the image floating method is proposed. The integral imaging is one of the most promising methods among the autostereoscopic displays and the integrated image has the volumetric characteristics unlike the other stereoscopic images. The image floating is a common 3D display technique, which uses a big convex lens or a concave mirror to exhibit the image of a real object to the observer. The image floating method can be used to emphasize the viewing characteristics of the volumetric image and the noise image which is located on the fixed plane can be eliminated by the floating lens through the control of the focal length. In this paper, the solution of the seam noise and the image flipping of the integral imaging system is proposed using the image floating method. Moreover, the advanced techniques of the integral imaging system can be directly applied to the proposed system. The proposed system can be successfully applied to many 3D applications such as 3D television.

  13. Illusion-related brain activations: a new virtual reality mirror box system for use during functional magnetic resonance imaging.

    PubMed

    Diers, Martin; Kamping, Sandra; Kirsch, Pinar; Rance, Mariela; Bekrater-Bodmann, Robin; Foell, Jens; Trojan, Joerg; Fuchs, Xaver; Bach, Felix; Maaß, Heiko; Cakmak, Hüseyin; Flor, Herta

    2015-01-12

    Extended viewing of movements of one's intact limb in a mirror as well as motor imagery have been shown to decrease pain in persons with phantom limb pain or complex regional pain syndrome and to increase the movement ability in hemiparesis following stroke. In addition, mirrored movements differentially activate sensorimotor cortex in amputees with and without phantom limb pain. However, using a so-called mirror box has technical limitations, some of which can be overcome by virtual reality applications. We developed a virtual reality mirror box application and evaluated its comparability to a classical mirror box setup. We applied both paradigms to 20 healthy controls and analyzed vividness and authenticity of the illusion as well as brain activation patterns. In both conditions, subjects reported similar intensities for the sensation that movements of the virtual left hand felt as if they were executed by their own left hand. We found activation in the primary sensorimotor cortex contralateral to the actual movement, with stronger activation for the virtual reality 'mirror box' compared to the classical mirror box condition, as well as activation in the primary sensorimotor cortex contralateral to the mirrored/virtual movement. We conclude that a virtual reality application of the mirror box is viable and that it might be useful for future research.

  14. Illusion-related brain activations: a new virtual reality mirror box system for use during functional magnetic resonance imaging.

    PubMed

    Diers, Martin; Kamping, Sandra; Kirsch, Pinar; Rance, Mariela; Bekrater-Bodmann, Robin; Foell, Jens; Trojan, Joerg; Fuchs, Xaver; Bach, Felix; Maaß, Heiko; Cakmak, Hüseyin; Flor, Herta

    2015-01-12

    Extended viewing of movements of one's intact limb in a mirror as well as motor imagery have been shown to decrease pain in persons with phantom limb pain or complex regional pain syndrome and to increase the movement ability in hemiparesis following stroke. In addition, mirrored movements differentially activate sensorimotor cortex in amputees with and without phantom limb pain. However, using a so-called mirror box has technical limitations, some of which can be overcome by virtual reality applications. We developed a virtual reality mirror box application and evaluated its comparability to a classical mirror box setup. We applied both paradigms to 20 healthy controls and analyzed vividness and authenticity of the illusion as well as brain activation patterns. In both conditions, subjects reported similar intensities for the sensation that movements of the virtual left hand felt as if they were executed by their own left hand. We found activation in the primary sensorimotor cortex contralateral to the actual movement, with stronger activation for the virtual reality 'mirror box' compared to the classical mirror box condition, as well as activation in the primary sensorimotor cortex contralateral to the mirrored/virtual movement. We conclude that a virtual reality application of the mirror box is viable and that it might be useful for future research. PMID:25446453

  15. Inertial imaging with nanomechanical systems.

    PubMed

    Hanay, M Selim; Kelber, Scott I; O'Connell, Cathal D; Mulvaney, Paul; Sader, John E; Roukes, Michael L

    2015-04-01

    Mass sensing with nanoelectromechanical systems has advanced significantly during the last decade. With nanoelectromechanical systems sensors it is now possible to carry out ultrasensitive detection of gaseous analytes, to achieve atomic-scale mass resolution and to perform mass spectrometry on single proteins. Here, we demonstrate that the spatial distribution of mass within an individual analyte can be imaged--in real time and at the molecular scale--when it adsorbs onto a nanomechanical resonator. Each single-molecule adsorption event induces discrete, time-correlated perturbations to all modal frequencies of the device. We show that by continuously monitoring a multiplicity of vibrational modes, the spatial moments of mass distribution can be deduced for individual analytes, one-by-one, as they adsorb. We validate this method for inertial imaging, using both experimental measurements of multimode frequency shifts and numerical simulations, to analyse the inertial mass, position of adsorption and the size and shape of individual analytes. Unlike conventional imaging, the minimum analyte size detectable through nanomechanical inertial imaging is not limited by wavelength-dependent diffraction phenomena. Instead, frequency fluctuation processes determine the ultimate attainable resolution. Advanced nanoelectromechanical devices appear capable of resolving molecular-scale analytes.

  16. Stereoscopic wide field of view imaging system

    NASA Technical Reports Server (NTRS)

    Prechtl, Eric F. (Inventor); Sedwick, Raymond J. (Inventor); Jonas, Eric M. (Inventor)

    2011-01-01

    A stereoscopic imaging system incorporates a plurality of imaging devices or cameras to generate a high resolution, wide field of view image database from which images can be combined in real time to provide wide field of view or panoramic or omni-directional still or video images.

  17. Imaging systems and materials characterization

    SciTech Connect

    Murr, L.E.

    2009-05-15

    This paper provides a broad background for the historical development and modern applications of light optical metallography, scanning and transmission electron microscopy, field-ion microscopy and several forms of scanning probe microscopes. Numerous case examples illustrating especially synergistic applications of these imaging systems are provided to demonstrate materials characterization especially in the context of structure-property-performance issues which define materials science and engineering.

  18. Pulsed laser linescanner for a backscatter absorption gas imaging system

    DOEpatents

    Kulp, Thomas J.; Reichardt, Thomas A.; Schmitt, Randal L.; Bambha, Ray P.

    2004-02-10

    An active (laser-illuminated) imaging system is described that is suitable for use in backscatter absorption gas imaging (BAGI). A BAGI imager operates by imaging a scene as it is illuminated with radiation that is absorbed by the gas to be detected. Gases become "visible" in the image when they attenuate the illumination creating a shadow in the image. This disclosure describes a BAGI imager that operates in a linescanned manner using a high repetition rate pulsed laser as its illumination source. The format of this system allows differential imaging, in which the scene is illuminated with light at least 2 wavelengths--one or more absorbed by the gas and one or more not absorbed. The system is designed to accomplish imaging in a manner that is insensitive to motion of the camera, so that it can be held in the hand of an operator or operated from a moving vehicle.

  19. Imaging methodologies for systems biology.

    PubMed

    Smith, Sarah E; Slaughter, Brian D; Unruh, Jay R

    2014-01-01

    Systems biology has recently achieved significant success in the understanding of complex interconnected phenomena such as cell polarity and migration. In this context, the definition of systems biology has come to encompass the integration of quantitative measurements with sophisticated modeling approaches. This article will review recent progress in live cell imaging technologies that have expanded the possibilities of quantitative in vivo measurements, particularly in regards to molecule counting and quantitative measurements of protein concentration and dynamics. These methods have gained and continue to gain popularity with the biological community. In general, we will discuss three broad categories: protein interactions, protein quantitation, and protein dynamics. PMID:25482526

  20. Validating a Geographical Image Retrieval System.

    ERIC Educational Resources Information Center

    Zhu, Bin; Chen, Hsinchun

    2000-01-01

    Summarizes a prototype geographical image retrieval system that demonstrates how to integrate image processing and information analysis techniques to support large-scale content-based image retrieval. Describes an experiment to validate the performance of this image retrieval system against that of human subjects by examining similarity analysis…

  1. Active vs. inactive muscle (image)

    MedlinePlus

    ... may lose 20 to 40 percent of their muscle -- and, along with it, their strength -- as they ... have found that a major reason people lose muscle is because they stop doing everyday activities that ...

  2. Design of a dynamic dual-foveated imaging system.

    PubMed

    Du, Xiaoyu; Chang, Jun; Zhang, Yunqiang; Wang, Xi; Zhang, Bochuan; Gao, Lei; Xiao, Liping

    2015-10-01

    A new kind of dynamic dual-foveated imaging system in the infrared band is designed and optimized in this paper. Dual-foveated imaging refers to the variation in spatial resolution at the two selected fields across the image. Such variable resolution imaging system is suitable for a variety of applications including monitoring, recognition, and remote operation of unmanned aerial vehicle. In this system, a transmissive spatial light modulator (SLM) is used as an active optical element which is located near the image plane instead of pupil plane creatively in order to divide the two selected fields. PMID:26480118

  3. Image and information management system

    NASA Technical Reports Server (NTRS)

    Robertson, Tina L. (Inventor); Raney, Michael C. (Inventor); Dougherty, Dennis M. (Inventor); Kent, Peter C. (Inventor); Brucker, Russell X. (Inventor); Lampert, Daryl A. (Inventor)

    2007-01-01

    A system and methods through which pictorial views of an object's configuration, arranged in a hierarchical fashion, are navigated by a person to establish a visual context within the configuration. The visual context is automatically translated by the system into a set of search parameters driving retrieval of structured data and content (images, documents, multimedia, etc.) associated with the specific context. The system places hot spots, or actionable regions, on various portions of the pictorials representing the object. When a user interacts with an actionable region, a more detailed pictorial from the hierarchy is presented representing that portion of the object, along with real-time feedback in the form of a popup pane containing information about that region, and counts-by-type reflecting the number of items that are available within the system associated with the specific context and search filters established at that point in time.

  4. Image and information management system

    NASA Technical Reports Server (NTRS)

    Robertson, Tina L. (Inventor); Raney, Michael C. (Inventor); Dougherty, Dennis M. (Inventor); Kent, Peter C. (Inventor); Brucker, Russell X. (Inventor); Lampert, Daryl A. (Inventor)

    2009-01-01

    A system and methods through which pictorial views of an object's configuration, arranged in a hierarchical fashion, are navigated by a person to establish a visual context within the configuration. The visual context is automatically translated by the system into a set of search parameters driving retrieval of structured data and content (images, documents, multimedia, etc.) associated with the specific context. The system places ''hot spots'', or actionable regions, on various portions of the pictorials representing the object. When a user interacts with an actionable region, a more detailed pictorial from the hierarchy is presented representing that portion of the object, along with real-time feedback in the form of a popup pane containing information about that region, and counts-by-type reflecting the number of items that are available within the system associated with the specific context and search filters established at that point in time.

  5. Advanced Imaging Algorithms for Radiation Imaging Systems

    SciTech Connect

    Marleau, Peter

    2015-10-01

    The intent of the proposed work, in collaboration with University of Michigan, is to develop the algorithms that will bring the analysis from qualitative images to quantitative attributes of objects containing SNM. The first step to achieving this is to develop an indepth understanding of the intrinsic errors associated with the deconvolution and MLEM algorithms. A significant new effort will be undertaken to relate the image data to a posited three-dimensional model of geometric primitives that can be adjusted to get the best fit. In this way, parameters of the model such as sizes, shapes, and masses can be extracted for both radioactive and non-radioactive materials. This model-based algorithm will need the integrated response of a hypothesized configuration of material to be calculated many times. As such, both the MLEM and the model-based algorithm require significant increases in calculation speed in order to converge to solutions in practical amounts of time.

  6. Pioneer imaging photopolarimeter optical system.

    NASA Technical Reports Server (NTRS)

    Pellicori, S. F.; Russell, E. E.; Watts, L. A.

    1973-01-01

    The imaging photopolarimeter aboard the Pioneer 10 spacecraft en route to the vicinity of Jupiter is described. This instrument is capable of moderate resolution spin-scan imaging and high precision polarimetric and photometric mapping of Jupiter in red and blue light. The field of view can be selectively changed from 0.50 mrad square to 40 mrad square to accommodate resolution and radiance combinations ranging from the zodiacal background to that of Jupiter. Optical materials were chosen to survive, with minimum degradation, the rigors of a nearly 2-year journey to Jupiter including transit through the Jovian trapped radiation belts. The optics are described in detail, and the operational system is outlined. The procedures for preflight and in-flight calibration are described, and some performance characteristics and preliminary flight results are presented.

  7. Pioneer imaging photopolarimeter optical system.

    PubMed

    Pellicori, S F; Russell, E E; Watts, L A

    1973-06-01

    The imaging photopolarimeter aboard the Pioneer 10 spacecraft en route to the vicinity of Jupiter is described. This instrument is capable of moderate resolution spin-scan imaging and high precision polarimetric and photometric mapping of Jupiter in red and blue light. The field of view can be selectively changed from 0.50 mrad square to 40 mrad square to accommodate resolution and radiance combinations ranging from the zodiacal background to that of Jupiter. The dynamic range (radiance) of the instrument is greater than 10(8). Optical materials were chosen to survive, with minimum degradation, the rigors of a nearly 2-year journey to Jupiter including transit through the Jovian trapped radiation belts. The optics are described in detail, and the operational system is outlined. The procedures for preflight and in-flight calibration are described, and some performance characteristics and preliminary flight results are presented. PMID:20125507

  8. Single System Image Cluster Management

    2004-02-13

    Cluster computing has quickly proven itself to be a capable workhorse for a wide variety of production computing tasks; however, setting up and maintaining a cluster still requires significantly more effort than administrating just a single machine. As computing hardware descreases in price and cluster sizes grow, it is becoming increasingly important to manage clusters cleverly so that a system administration effort can "scale" as well. To ease the task of mananging many machines, administratorsmore » often deploy an environment that is homogeneous across all nodes of a cluster, and maintain a snapshot of the filesystem as a 'master image'. However due to operational, behavioral, and physical constraints, many nodes often require numerous deviations from the master image in order to operate as desired.« less

  9. Interactive digital image manipulation system

    NASA Technical Reports Server (NTRS)

    Henze, J.; Dezur, R.

    1975-01-01

    The system is designed for manipulation, analysis, interpretation, and processing of a wide variety of image data. LANDSAT (ERTS) and other data in digital form can be input directly into the system. Photographic prints and transparencies are first converted to digital form with an on-line high-resolution microdensitometer. The system is implemented on a Hewlett-Packard 3000 computer with 128 K bytes of core memory and a 47.5 megabyte disk. It includes a true color display monitor, with processing memories, graphics overlays, and a movable cursor. Image data formats are flexible so that there is no restriction to a given set of remote sensors. Conversion between data types is available to provide a basis for comparison of the various data. Multispectral data is fully supported, and there is no restriction on the number of dimensions. In this way multispectral data collected at more than one point in time may simply be treated as a data collected with twice (three times, etc.) the number of sensors. There are various libraries of functions available to the user: processing functions, display functions, system functions, and earth resources applications functions.

  10. Multi-channel medical imaging system

    DOEpatents

    Frangioni, John V.

    2016-05-03

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in a subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  11. Multi-channel medical imaging system

    SciTech Connect

    Frangioni, John V

    2013-12-31

    A medical imaging system provides simultaneous rendering of visible light and fluorescent images. The system may employ dyes in a small-molecule form that remain in the subject's blood stream for several minutes, allowing real-time imaging of the subject's circulatory system superimposed upon a conventional, visible light image of the subject. The system may provide an excitation light source to excite the fluorescent substance and a visible light source for general illumination within the same optical guide used to capture images. The system may be configured for use in open surgical procedures by providing an operating area that is closed to ambient light. The systems described herein provide two or more diagnostic imaging channels for capture of multiple, concurrent diagnostic images and may be used where a visible light image may be usefully supplemented by two or more images that are independently marked for functional interest.

  12. High resolution multimodal clinical ophthalmic imaging system.

    PubMed

    Mujat, Mircea; Ferguson, R Daniel; Patel, Ankit H; Iftimia, Nicusor; Lue, Niyom; Hammer, Daniel X

    2010-05-24

    We developed a multimodal adaptive optics (AO) retinal imager which is the first to combine high performance AO-corrected scanning laser ophthalmoscopy (SLO) and swept source Fourier domain optical coherence tomography (SSOCT) imaging modes in a single compact clinical prototype platform. Such systems are becoming ever more essential to vision research and are expected to prove their clinical value for diagnosis of retinal diseases, including glaucoma, diabetic retinopathy (DR), age-related macular degeneration (AMD), and retinitis pigmentosa. The SSOCT channel operates at a wavelength of 1 microm for increased penetration and visualization of the choriocapillaris and choroid, sites of major disease activity for DR and wet AMD. This AO system is designed for use in clinical populations; a dual deformable mirror (DM) configuration allows simultaneous low- and high-order aberration correction over a large range of refractions and ocular media quality. The system also includes a wide field (33 deg.) line scanning ophthalmoscope (LSO) for initial screening, target identification, and global orientation, an integrated retinal tracker (RT) to stabilize the SLO, OCT, and LSO imaging fields in the presence of lateral eye motion, and a high-resolution LCD-based fixation target for presentation of visual cues. The system was tested in human subjects without retinal disease for performance optimization and validation. We were able to resolve and quantify cone photoreceptors across the macula to within approximately 0.5 deg (approximately 100-150 microm) of the fovea, image and delineate ten retinal layers, and penetrate to resolve features deep into the choroid. The prototype presented here is the first of a new class of powerful flexible imaging platforms that will provide clinicians and researchers with high-resolution, high performance adaptive optics imaging to help guide therapies, develop new drugs, and improve patient outcomes.

  13. Mitochondrial Nitroreductase Activity Enables Selective Imaging and Therapeutic Targeting.

    PubMed

    Chevalier, Arnaud; Zhang, Yanmin; Khdour, Omar M; Kaye, Justin B; Hecht, Sidney M

    2016-09-21

    Nitroreductase (NTR) activities have been known for decades, studied extensively in bacteria and also in systems as diverse as yeast, trypanosomes, and hypoxic tumors. The putative bacterial origin of mitochondria prompted us to explore the possible existence of NTR activity within this organelle and to probe its behavior in a cellular context. Presently, by using a profluorescent near-infrared (NIR) dye, we characterize the nature of NTR activity localized in mammalian cell mitochondria. Further, we demonstrate that this mitochondrially localized enzymatic activity can be exploited both for selective NIR imaging of mitochondria and for mitochondrial targeting by activating a mitochondrial poison specifically within that organelle. This constitutes a new mechanism for mitochondrial imaging and targeting. These findings represent the first use of mitochondrial enzyme activity to unmask agents for mitochondrial fluorescent imaging and therapy, which may prove to be more broadly applicable.

  14. Stochastic image reconstruction for a dual-particle imaging system

    NASA Astrophysics Data System (ADS)

    Hamel, M. C.; Polack, J. K.; Poitrasson-Rivière, A.; Flaska, M.; Clarke, S. D.; Pozzi, S. A.; Tomanin, A.; Peerani, P.

    2016-02-01

    Stochastic image reconstruction has been applied to a dual-particle imaging system being designed for nuclear safeguards applications. The dual-particle imager (DPI) is a combined Compton-scatter and neutron-scatter camera capable of producing separate neutron and photon images. The stochastic origin ensembles (SOE) method was investigated as an imaging method for the DPI because only a minimal estimation of system response is required to produce images with quality that is comparable to common maximum-likelihood methods. This work contains neutron and photon SOE image reconstructions for a 252Cf point source, two mixed-oxide (MOX) fuel canisters representing point sources, and the MOX fuel canisters representing a distributed source. Simulation of the DPI using MCNPX-PoliMi is validated by comparison of simulated and measured results. Because image quality is dependent on the number of counts and iterations used, the relationship between these quantities is investigated.

  15. Auto-Versioning Systems Image Manager

    2013-08-01

    The av_sys_image_mgr utility provides an interface for the creation, manipulation, and analysis of system boot images for computer systems. It is primarily intended to provide a convenient method for managing the introduction of changes to boot images for long-lived production HPC systems.

  16. The Tile and General Research Imaging System (TIGRIS)

    SciTech Connect

    Simpson, J.J.; Al-Rawi, L.L.

    1996-01-01

    The Tile and General Research Imaging System (TIGRIS) is a UNIX-based image software system implemented in, and strictly conforming to, UNIX, C/ANSI C, and X11 Window standards. The TIGRIS design and implementation emulates UNIX at the user, application, and system levels. The TIGRIS Application Programmer Interface (API) provides a convenient way to create divers image processing and analysis applications. TIGRIS has been used primarily to support satellite remote sensing, global change research, and operational activities. Numerous applications related to specific remote sensing issues (e.g., cloud detection, noise reduction in AVHRR Channel 3 data, oceanic transport) are included in the application layer. In addition, a number of powerful general purpose imaging applications (e.g., image algebra, morphological operations, textural analysis) are provided which support general image processing, analysis, interactive visualization, and noninteractive image product generation. Use of TIGRIS to accomplish a few complex image analysis tasks is demonstrated.

  17. Solar active region display system

    NASA Astrophysics Data System (ADS)

    Golightly, M.; Raben, V.; Weyland, M.

    2003-04-01

    The Solar Active Region Display System (SARDS) is a client-server application that automatically collects a wide range of solar data and displays it in a format easy for users to assimilate and interpret. Users can rapidly identify active regions of interest or concern from color-coded indicators that visually summarize each region's size, magnetic configuration, recent growth history, and recent flare and CME production. The active region information can be overlaid onto solar maps, multiple solar images, and solar difference images in orthographic, Mercator or cylindrical equidistant projections. Near real-time graphs display the GOES soft and hard x-ray flux, flare events, and daily F10.7 value as a function of time; color-coded indicators show current trends in soft x-ray flux, flare temperature, daily F10.7 flux, and x-ray flare occurrence. Through a separate window up to 4 real-time or static graphs can simultaneously display values of KP, AP, daily F10.7 flux, GOES soft and hard x-ray flux, GOES >10 and >100 MeV proton flux, and Thule neutron monitor count rate. Climatologic displays use color-valued cells to show F10.7 and AP values as a function of Carrington/Bartel's rotation sequences - this format allows users to detect recurrent patterns in solar and geomagnetic activity as well as variations in activity levels over multiple solar cycles. Users can customize many of the display and graph features; all displays can be printed or copied to the system's clipboard for "pasting" into other applications. The system obtains and stores space weather data and images from sources such as the NOAA Space Environment Center, NOAA National Geophysical Data Center, the joint ESA/NASA SOHO spacecraft, and the Kitt Peak National Solar Observatory, and can be extended to include other data series and image sources. Data and images retrieved from the system's database are converted to XML and transported from a central server using HTTP and SOAP protocols, allowing

  18. Using an image retrieval system for image data management

    NASA Astrophysics Data System (ADS)

    Karnowski, Thomas P.; Tobin, Kenneth W., Jr.; Ferrell, Regina K.; Jatko, William B.; Lakhani, Fred

    2002-07-01

    Images of semiconductor defects are maintained in semiconductor yield-management systems to help diagnose problems that arise during the manufacturing process. A common problem in future systems is the number of images to maintain, which is increasing at an alarming rate due to the growing use of in-line and off-line imaging systems. A manufacturing-specific content-based image retrieval system, or Automated Image Retrieval (AIR) system, was developed by ORNL in coordination with International SEMATECH during 1998-1999. The system uses commercial databases to store image information and uses a customized indexing technology to rapidly retrieve similar images base don visual content. In addition to acting as a yield management tool based on storing and retrieving images, the system can be utilized as a tool for data management by helping determine when images are redundant in relation to previously stored data. Ideally this information can be used to time-stamp the data for future purging based on a variety of ratings such as 'long- term', 'mid-term', and 'short-term'. In some situations the feedback from the AIR system can even be used to omit the image entirely based on pre-existing close matches. In this paper we explore techniques for using the AIR system to assist in image data management. Experimental results are shown with simulated image data representing various degrees of image clustering of redundancy, and manufacturing image data accumulated during earlier field-testing of the AIR system at industry sites. Early results indicate substantial reductions in the size of industry databases may be achievable while continuing to maintain an adequate representation and history of the manufacturing process. To reduce the number of stored images, AIR technology can be used in place of, or as a guide for, the typical 'store for N months and purge' approach to image management. This approach will enhance the use of the image database, since the real bottleneck in

  19. Information Systems - Cancer Imaging Program

    Cancer.gov

    The Lung Image Database Consortium (LIDC) represents an effort by CIP grantees in a consortium to create a database of spiral CT images of the lung for use in CAD (computer-aided detection) algorithm research. The Imaging Database Resources Initiative (IDRI) is extending the efforts of the LIDC, to create a larger database of spiral CT imaging of the lung for use in CAD algorithm research. Image Archive Resources contains links to Web sites related to the interests of the NCI CIP Image Archive Committee. The Molecular Imaging and Contrast Agent Database (MICAD) is a database of research data on in vivo molecular imaging and contrast agents.

  20. Episode image analysis for wearable daily life recording system

    NASA Astrophysics Data System (ADS)

    Toda, Masashi; Nagasaki, Takeshi; Kawashima, Toshio

    2003-06-01

    Now we are developing a wearable recording system which can capture images from user"s view point in user"s everyday life automatically. The user refers to the images which is acquired using this system later, and these images support a user"s activity, such as human memory and human thoughts. Amount images which are acquired becomes so huge that it is difficult for the user to refer them. So the mechanism for viewing effectively is very important, such as summary. In this research, we describe the concept for summary mechanism of everyday life images.

  1. Infrared Imaging System for Studying Brain Function

    NASA Technical Reports Server (NTRS)

    Mintz, Frederick; Mintz, Frederick; Gunapala, Sarath

    2007-01-01

    A proposed special-purpose infrared imaging system would be a compact, portable, less-expensive alternative to functional magnetic resonance imaging (fMRI) systems heretofore used to study brain function. Whereas a typical fMRI system fills a large room, and must be magnetically isolated, this system would fit into a bicycle helmet. The system would include an assembly that would be mounted inside the padding in a modified bicycle helmet or other suitable headgear. The assembly would include newly designed infrared photodetectors and data-acquisition circuits on integrated-circuit chips on low-thermal-conductivity supports in evacuated housings (see figure) arranged in multiple rows and columns that would define image coordinates. Each housing would be spring-loaded against the wearer s head. The chips would be cooled by a small Stirling Engine mounted contiguous to, but thermally isolated from, the portions of the assembly in thermal contact with the wearer s head. Flexible wires or cables for transmitting data from the aforementioned chips would be routed to an integrated, multichannel transmitter and thence through the top of the assembly to a patch antenna on the outside of the helmet. The multiple streams of data from the infrared-detector chips would be sent to a remote site, where they would be processed, by software, into a three-dimensional display of evoked potentials that would represent firing neuronal bundles and thereby indicate locations of neuronal activity associated with mental or physical activity. The 3D images will be analogous to current fMRI images. The data would also be made available, in real-time, for comparison with data in local or internationally accessible relational databases that already exist in universities and research centers. Hence, this system could be used in research on, and for the diagnosis of response from the wearer s brain to physiological, psychological, and environmental changes in real time. The images would also be

  2. Measurement of image plane illumination uniformity of photoelectric imaging system

    NASA Astrophysics Data System (ADS)

    Kang, Deng-kui; Yang, Hong; Sha, Ding-guo; Jiang, Chang-lu; Chen, Min; Zhong, Xing-hui; Ma, Shi-bang; Yuan, Liang

    2014-09-01

    The image plane illumination nonuniformity caused by optical system or detector will affect the detection precision of photoelectric imaging system, especially in image guidance, positioning and recognition. An image plane illumination uniformity measurement device was set up, which was characteristiced of high uniformity and wide dynamic range. The device was composed of an asymmetric integrating sphere,the image collection and processing system, as well as the electrical control system.The asymmetric integrating sphere had two different radius,which was respectively 800mm and 1000mm.The spectral region was (0.4~1.1)μm, the illumination range was (1×10-4~2×104)lx. The image collection and processing system had two different acquisition card,which were respectively used for analog and digital signals. The software can process for dynamic image or static image. The TracePro software was used to make a internal ray tracing of integrating sphere, the illumination uniformity at the export was simulated for the size of 330mm×230mm and Φ 100mm export, the results were respectively 97.95% and 98.33%. Then,an illuminometer was used to measure the actual illumination uniformity of integrating sphere, the result was shown the actual illumination uniformity was 98.8%. Finally, a visible photoelectric imaging system was tested ,and three different uniformity indicators results were given.

  3. Improved Interactive Medical-Imaging System

    NASA Technical Reports Server (NTRS)

    Ross, Muriel D.; Twombly, Ian A.; Senger, Steven

    2003-01-01

    An improved computational-simulation system for interactive medical imaging has been invented. The system displays high-resolution, three-dimensional-appearing images of anatomical objects based on data acquired by such techniques as computed tomography (CT) and magnetic-resonance imaging (MRI). The system enables users to manipulate the data to obtain a variety of views for example, to display cross sections in specified planes or to rotate images about specified axes. Relative to prior such systems, this system offers enhanced capabilities for synthesizing images of surgical cuts and for collaboration by users at multiple, remote computing sites.

  4. Activating Attachments Reduces Memories of Traumatic Images.

    PubMed

    Bryant, Richard A; Foord, Rachael

    2016-01-01

    Emotional memories, and especially intrusive memories, are a common feature of many psychological disorders, and are overconsolidated by stress. Attachment theory posits that activation of mental representations of attachment figures can reduce stress and boost coping. This study tested the proposition that attachment activation would reduce consolidation of emotional and intrusive memories. Sixty-seven undergraduate students viewed subliminal presentations of traumatic and neutral images, which were preceded by subliminal presentations of either attachment-related images or non-attachment-related images; free recall and intrusive memories were assessed two days later. Participants with low avoidant attachment tendencies who received the attachment primes recalled fewer memories and reported fewer intrusions than those who received the non-attachment primes. Unexpectedly, those with high anxious attachment tendencies reported fewer memories. These findings generally accord with attachment theory, and suggest that consolidation of emotional memories can be moderated by activation of attachment representations. PMID:27631498

  5. Activating Attachments Reduces Memories of Traumatic Images.

    PubMed

    Bryant, Richard A; Foord, Rachael

    2016-01-01

    Emotional memories, and especially intrusive memories, are a common feature of many psychological disorders, and are overconsolidated by stress. Attachment theory posits that activation of mental representations of attachment figures can reduce stress and boost coping. This study tested the proposition that attachment activation would reduce consolidation of emotional and intrusive memories. Sixty-seven undergraduate students viewed subliminal presentations of traumatic and neutral images, which were preceded by subliminal presentations of either attachment-related images or non-attachment-related images; free recall and intrusive memories were assessed two days later. Participants with low avoidant attachment tendencies who received the attachment primes recalled fewer memories and reported fewer intrusions than those who received the non-attachment primes. Unexpectedly, those with high anxious attachment tendencies reported fewer memories. These findings generally accord with attachment theory, and suggest that consolidation of emotional memories can be moderated by activation of attachment representations.

  6. Activating Attachments Reduces Memories of Traumatic Images

    PubMed Central

    Foord, Rachael

    2016-01-01

    Emotional memories, and especially intrusive memories, are a common feature of many psychological disorders, and are overconsolidated by stress. Attachment theory posits that activation of mental representations of attachment figures can reduce stress and boost coping. This study tested the proposition that attachment activation would reduce consolidation of emotional and intrusive memories. Sixty-seven undergraduate students viewed subliminal presentations of traumatic and neutral images, which were preceded by subliminal presentations of either attachment-related images or non-attachment-related images; free recall and intrusive memories were assessed two days later. Participants with low avoidant attachment tendencies who received the attachment primes recalled fewer memories and reported fewer intrusions than those who received the non-attachment primes. Unexpectedly, those with high anxious attachment tendencies reported fewer memories. These findings generally accord with attachment theory, and suggest that consolidation of emotional memories can be moderated by activation of attachment representations. PMID:27631498

  7. Object classification and acoustic imaging with active sonar.

    PubMed

    Kelly, J G; Carpenter, R N; Tague, J A

    1992-04-01

    The theoretical underpinnings of underwater acoustic classification and imaging using high-frequency active sonar are studied. All essential components of practical classification systems are incorporated in a Bayesian theoretic framework. The optimum decision rules and array processing are presented and evaluated. A systematic performance evaluation methodology is derived. New results quantify the relationship between classifier performance and object geometry, acoustic imaging, and the accuracy of a priori knowledge infused into the processor.

  8. The ascending reticular activating system from pontine reticular formation to the hypothalamus in the human brain: a diffusion tensor imaging study.

    PubMed

    Jang, Sung Ho; Kwon, Hyeok Gyu

    2015-03-17

    The ascending reticular activating system (ARAS) is responsible for regulation of consciousness. Precise evaluation of the ARAS is important for diagnosis and management of patients with impaired consciousness. In the current study, we attempted to reconstruct the portion of the ARAS from the pontine reticular formation (RF) to the hypothalamus in normal subjects, using diffusion tensor imaging (DTI). A total of 31 healthy subjects were recruited for this study. DTI scanning was performed using 1.5-T, and the ARAS from the pontine RF to the hypothalamus was reconstructed. Values of fractional anisotropy, mean diffusivity, and tract volume of the ARAS from the pontine RF to the hypothalamus were measured. In all subjects, the ARAS from the pontine RF to the hypothalamus originated from the RF at the level of the mid-pons, where the trigeminal nerve could be seen, ascended through the periaqueductal gray matter of the midbrain anterolaterally to the anterior commissure level, and then terminated into the hypothalamus. No significant differences in DTI parameters were observed between the left and right hemispheres and between males and females (p<0.05). We identified the ARAS between the pontine RF and the hypothalamus in normal subjects using DTI. We believe that the reconstruction methodology and the results of this study would be useful to clinicians involved in the care of patients with impaired consciousness and researchers in studies of the ARAS.

  9. Along-Track Reef Imaging System (ATRIS)

    USGS Publications Warehouse

    Brock, John; Zawada, Dave

    2006-01-01

    "Along-Track Reef Imaging System (ATRIS)" describes the U.S. Geological Survey's Along-Track Reef Imaging System, a boat-based sensor package for rapidly mapping shallow water benthic environments. ATRIS acquires high resolution, color digital images that are accurately geo-located in real-time.

  10. MIARS: a medical image retrieval system.

    PubMed

    Mueen, A; Zainuddin, R; Baba, M Sapiyan

    2010-10-01

    The next generation of medical information system will integrate multimedia data to assist physicians in clinical decision-making, diagnoses, teaching, and research. This paper describes MIARS (Medical Image Annotation and Retrieval System). MIARS not only provides automatic annotation, but also supports text based as well as image based retrieval strategies, which play important roles in medical training, research, and diagnostics. The system utilizes three trained classifiers, which are trained using training images. The goal of these classifiers is to provide multi-level automatic annotation. Another main purpose of the MIARS system is to study image semantic retrieval strategy by which images can be retrieved according to different levels of annotation.

  11. Active place recognition using image signatures

    NASA Astrophysics Data System (ADS)

    Engelson, Sean P.

    1992-11-01

    For reliable navigation, a mobile robot needs to be able to recognize where it is in the world. We previously described an efficient and effective image-based representation of perceptual information for place recognition. Each place is associated with a set of stored image signatures, each a matrix of numbers derived by evaluating some measurement functions over large blocks of pixels. One difficulty, though, is the large number of inherently ambiguous signatures which bloats the database and makes recognition more difficult. Furthermore, since small differences in orientation can produce very different images, reliable recognition requires many images. These problems can be ameliorated by using active methods to select the best signatures to use for the recognition. Two criteria for good images are distinctiveness (is the scene distinguishable from others?) and stability (how much do small viewpoint motions change image recognizability?). We formulate several heuristic distinctiveness metrics which are good predictors of real image distinctiveness. These functions are then used to direct the motion of the camera to find locally distinctive views for use in recognition. This method also produces some modicum of stability, since it uses a form of local optimization. We present the results of applying this method with a camera mounted on a pan-tilt platform.

  12. Image acquisition system for a hospital enterprise

    NASA Astrophysics Data System (ADS)

    Moore, Stephen M.; Beecher, David E.

    1998-07-01

    Hospital enterprises are being created through mergers and acquisitions of existing hospitals. One area of interest in the PACS literature has been the integration of information systems and imaging systems. Hospital enterprises with multiple information and imaging systems provide new challenges to the integration task. This paper describes the requirements at the BJC Health System and a testbed system that is designed to acquire images from a number of different modalities and hospitals. This testbed system is integrated with Project Spectrum at BJC which is designed to provide a centralized clinical repository and a single desktop application for physician review of the patient chart (text, lab values, images).

  13. Research on range-gated laser active imaging seeker

    NASA Astrophysics Data System (ADS)

    You, Mu; Wang, PengHui; Tan, DongJie

    2013-09-01

    Compared with other imaging methods such as millimeter wave imaging, infrared imaging and visible light imaging, laser imaging provides both a 2-D array of reflected intensity data as well as 2-D array of range data, which is the most important data for use in autonomous target acquisition .In terms of application, it can be widely used in military fields such as radar, guidance and fuse. In this paper, we present a laser active imaging seeker system based on range-gated laser transmitter and sensor technology .The seeker system presented here consist of two important part, one is laser image system, which uses a negative lens to diverge the light from a pulse laser to flood illuminate a target, return light is collected by a camera lens, each laser pulse triggers the camera delay and shutter. The other is stabilization gimbals, which is designed to be a rotatable structure both in azimuth and elevation angles. The laser image system consists of transmitter and receiver. The transmitter is based on diode pumped solid-state lasers that are passively Q-switched at 532nm wavelength. A visible wavelength was chosen because the receiver uses a Gen III image intensifier tube with a spectral sensitivity limited to wavelengths less than 900nm.The receiver is image intensifier tube's micro channel plate coupled into high sensitivity charge coupled device camera. The image has been taken at range over one kilometer and can be taken at much longer range in better weather. Image frame frequency can be changed according to requirement of guidance with modifiable range gate, The instantaneous field of views of the system was found to be 2×2 deg. Since completion of system integration, the seeker system has gone through a series of tests both in the lab and in the outdoor field. Two different kinds of buildings have been chosen as target, which is located at range from 200m up to 1000m.To simulate dynamic process of range change between missile and target, the seeker system has

  14. Intelligence, mapping, and geospatial exploitation system (IMAGES)

    NASA Astrophysics Data System (ADS)

    Moellman, Dennis E.; Cain, Joel M.

    1998-08-01

    available and it will also provide statistical pedigree data. This pedigree data provides both uncertainties associated with the information and an audit trail cataloging the raw data sources and the processing/exploitation applied to derive the final product. Collaboration provides for a close union between the information producer(s)/exploiter(s) and the information user(s) as well as between local and remote producer(s)/exploiter(s). From a military operational perspective, IMAGES is a step toward further uniting NIMA with its customers and further blurring the dividing line between operational command and control (C2) and its supporting intelligence activities. IMAGES also provides a foundation for reachback to remote data sources, data stores, application software, and computational resources for achieving 'just-in- time' information delivery -- all of which is transparent to the analyst or operator employing the system.

  15. Low cost Image Transmission System

    SciTech Connect

    Skogmo, D.

    1994-06-01

    Throughout the Department of Energy (DOE) complex, sites protect themselves with intrusion detection systems. Some of these systems have sensors in remote areas. These sensors frequently alarm -- not because they have detected a terrorist skulking around the area, but because they have detected a horse, or a dog, or a bush moving in the breeze. Even though the local security force is 99% sure there is no real threat, they must assess each of these nuisance or false alarms. Generally, the procedure consists of dispatching an inspector to drive to the area and make an assessment. This is expensive in terms of manpower and the assessment is not timely. Often, by the time the inspector arrives, the cause of the alarm has vanished. A television camera placed to view the area protected by the sensor could be used to help in this assessment, but this requires the installation of high-quality cable, optical fiber, or a microwave link. Further, to be of use at the present time, the site must have had the foresight to have installed these facilities in the past and have them ready for use now. What is needed is a device to place between the television camera and a modem connecting to a low-bandwidth channel such as radio or a telephone line. This paper discusses the development of such a device: an Image Transmission System, or ITS.

  16. Web-based medical image archive system

    NASA Astrophysics Data System (ADS)

    Suh, Edward B.; Warach, Steven; Cheung, Huey; Wang, Shaohua A.; Tangiral, Phanidral; Luby, Marie; Martino, Robert L.

    2002-05-01

    This paper presents a Web-based medical image archive system in three-tier, client-server architecture for the storage and retrieval of medical image data, as well as patient information and clinical data. The Web-based medical image archive system was designed to meet the need of the National Institute of Neurological Disorders and Stroke for a central image repository to address questions of stroke pathophysiology and imaging biomarkers in stroke clinical trials by analyzing images obtained from a large number of clinical trials conducted by government, academic and pharmaceutical industry researchers. In the database management-tier, we designed the image storage hierarchy to accommodate large binary image data files that the database software can access in parallel. In the middle-tier, a commercial Enterprise Java Bean server and secure Web server manages user access to the image database system. User-friendly Web-interfaces and applet tools are provided in the client-tier for easy access to the image archive system over the Internet. Benchmark test results show that our three-tier image archive system yields fast system response time for uploading, downloading, and querying the image database.

  17. Developing stereo image based robot control system

    SciTech Connect

    Suprijadi,; Pambudi, I. R.; Woran, M.; Naa, C. F; Srigutomo, W.

    2015-04-16

    Application of image processing is developed in various field and purposes. In the last decade, image based system increase rapidly with the increasing of hardware and microprocessor performance. Many fields of science and technology were used this methods especially in medicine and instrumentation. New technique on stereovision to give a 3-dimension image or movie is very interesting, but not many applications in control system. Stereo image has pixel disparity information that is not existed in single image. In this research, we proposed a new method in wheel robot control system using stereovision. The result shows robot automatically moves based on stereovision captures.

  18. Handbook on COMTAL's Image Processing System

    NASA Technical Reports Server (NTRS)

    Faulcon, N. D.

    1983-01-01

    An image processing system is the combination of an image processor with other control and display devices plus the necessary software needed to produce an interactive capability to analyze and enhance image data. Such an image processing system installed at NASA Langley Research Center, Instrument Research Division, Acoustics and Vibration Instrumentation Section (AVIS) is described. Although much of the information contained herein can be found in the other references, it is hoped that this single handbook will give the user better access, in concise form, to pertinent information and usage of the image processing system.

  19. Technologies for imaging neural activity in large volumes.

    PubMed

    Ji, Na; Freeman, Jeremy; Smith, Spencer L

    2016-08-26

    Neural circuitry has evolved to form distributed networks that act dynamically across large volumes. Conventional microscopy collects data from individual planes and cannot sample circuitry across large volumes at the temporal resolution relevant to neural circuit function and behaviors. Here we review emerging technologies for rapid volume imaging of neural circuitry. We focus on two critical challenges: the inertia of optical systems, which limits image speed, and aberrations, which restrict the image volume. Optical sampling time must be long enough to ensure high-fidelity measurements, but optimized sampling strategies and point-spread function engineering can facilitate rapid volume imaging of neural activity within this constraint. We also discuss new computational strategies for processing and analyzing volume imaging data of increasing size and complexity. Together, optical and computational advances are providing a broader view of neural circuit dynamics and helping elucidate how brain regions work in concert to support behavior. PMID:27571194

  20. Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture

    SciTech Connect

    Lassahn, Gordon D.; Lancaster, Gregory D.; Apel, William A.; Thompson, Vicki S.

    2013-01-08

    Image portion identification methods, image parsing methods, image parsing systems, and articles of manufacture are described. According to one embodiment, an image portion identification method includes accessing data regarding an image depicting a plurality of biological substrates corresponding to at least one biological sample and indicating presence of at least one biological indicator within the biological sample and, using processing circuitry, automatically identifying a portion of the image depicting one of the biological substrates but not others of the biological substrates.

  1. PET imaging of the autonomic nervous system.

    PubMed

    Thackeray, James T; Bengel, Frank M

    2016-12-01

    The autonomic nervous system is the primary extrinsic control of heart rate and contractility, and is subject to adaptive and maladaptive changes in cardiovascular disease. Consequently, noninvasive assessment of neuronal activity and function is an attractive target for molecular imaging. A myriad of targeted radiotracers have been developed over the last 25 years for imaging various components of the sympathetic and parasympathetic signal cascades. While routine clinical use remains somewhat limited, a number of larger scale studies in recent years have supplied momentum to molecular imaging of autonomic signaling. Specifically, the findings of the ADMIRE HF trial directly led to United States Food and Drug Administration approval of 123I-metaiodobenzylguanidine (MIBG) for Single Photon Emission Computed Tomography (SPECT) assessment of sympathetic neuronal innervation, and comparable results have been reported using the analogous PET agent 11C-meta-hydroxyephedrine (HED). Due to the inherent capacity for dynamic quantification and higher spatial resolution, regional analysis may be better served by PET. In addition, preliminary clinical and extensive preclinical experience has provided a broad foundation of cardiovascular applications for PET imaging of the autonomic nervous system. Recent years have witnessed the growth of novel quantification techniques, expansion of multiple tracer studies, and improved understanding of the uptake of different radiotracers, such that the transitional biology of dysfunctional subcellular catecholamine handling can be distinguished from complete denervation. As a result, sympathetic neuronal molecular imaging is poised to play a role in individualized patient care, by stratifying cardiovascular risk, visualizing underlying biology, and guiding and monitoring therapy. PMID:27611712

  2. Communication Systems. Laboratory Activities.

    ERIC Educational Resources Information Center

    Sutherland, Barbara, Ed.

    This communication systems guide provides teachers with learning activities for secondary students. Introductory materials include an instructional planning outline and worksheet, an outline of essential elements, a list of objectives, a course description, and a content outline. The guide contains 32 modules on the following topics: story…

  3. Production Systems. Laboratory Activities.

    ERIC Educational Resources Information Center

    Gallaway, Ann, Ed.

    This production systems guide provides teachers with learning activities for secondary students. Introductory materials include an instructional planning outline and worksheet, an outline of essential elements, domains and objectives, a course description, and a content outline. The guide contains 30 modules on the following topics: production…

  4. A novel system of electrodes transparent to ultrasound for simultaneous detection of myoelectric activity and B-mode ultrasound images of skeletal muscles.

    PubMed

    Botter, A; Vieira, T M M; Loram, I D; Merletti, R; Hodson-Tole, E F

    2013-10-15

    Application of two-dimensional surface electrode arrays can provide a means of mapping motor unit action potentials on the skin surface above a muscle. The resulting muscle tissue displacement can be quantified, in a single plane, using ultrasound (US) imaging. Currently, however, it is not possible to simultaneously map spatio-temporal propagation of activation and resulting tissue strain. In this paper, we developed and tested a material that will enable concurrent measurement of two-dimensional surface electromyograms (EMGs) with US images. Specific protocols were designed to test the compatibility of this new electrode material, both with EMG recording and with US analysis. Key results indicate that, for this new electrode material, 1) the electrode-skin impedance is similar to that of arrays of electrodes reported in literature; 2) the reflection of US at the electrode-skin interface is negligible; 3) the likelihood of observing missing contacts, short-circuits, and artifacts in EMGs is not affected by the US probe; 4) movement of tissues sampled by US can be tracked accurately. We, therefore, conclude this approach will facilitate multimodal imaging of muscle to provide new spatio-temporal information regarding electromechanical function of muscle. This is relevant to basic physiology-biomechanics of active and passive force transmission through and between muscles, of motor unit spatio-temporal activity patterns, of their variation with architecture and task-related function, and of their adaptation with aging, training-exercise-disuse, neurological disease, and injury.

  5. Physical Optics Based Computational Imaging Systems

    NASA Astrophysics Data System (ADS)

    Olivas, Stephen Joseph

    There is an ongoing demand on behalf of the consumer, medical and military industries to make lighter weight, higher resolution, wider field-of-view and extended depth-of-focus cameras. This leads to design trade-offs between performance and cost, be it size, weight, power, or expense. This has brought attention to finding new ways to extend the design space while adhering to cost constraints. Extending the functionality of an imager in order to achieve extraordinary performance is a common theme of computational imaging, a field of study which uses additional hardware along with tailored algorithms to formulate and solve inverse problems in imaging. This dissertation details four specific systems within this emerging field: a Fiber Bundle Relayed Imaging System, an Extended Depth-of-Focus Imaging System, a Platform Motion Blur Image Restoration System, and a Compressive Imaging System. The Fiber Bundle Relayed Imaging System is part of a larger project, where the work presented in this thesis was to use image processing techniques to mitigate problems inherent to fiber bundle image relay and then, form high-resolution wide field-of-view panoramas captured from multiple sensors within a custom state-of-the-art imager. The Extended Depth-of-Focus System goals were to characterize the angular and depth dependence of the PSF of a focal swept imager in order to increase the acceptably focused imaged scene depth. The goal of the Platform Motion Blur Image Restoration System was to build a system that can capture a high signal-to-noise ratio (SNR), long-exposure image which is inherently blurred while at the same time capturing motion data using additional optical sensors in order to deblur the degraded images. Lastly, the objective of the Compressive Imager was to design and build a system functionally similar to the Single Pixel Camera and use it to test new sampling methods for image generation and to characterize it against a traditional camera. These computational

  6. Time-delay compensation for stabilization imaging system

    NASA Astrophysics Data System (ADS)

    Chen, Yueting; Xu, Zhihai; Li, Qi; Feng, Huajun

    2014-05-01

    The spatial resolution of imaging systems for airborne and space-borne remote sensing are often limited by image degradation resulting from mechanical vibrations of platforms during image exposure. A straightforward way to overcome this problem is to actively stabilize the optical axis or drive the focal plane synchronous to the motion image during exposure. Thus stabilization imaging system usually consists of digital image motion estimation and micromechanical compensation. The performance of such kind of visual servo system is closely related to precision of motion estimation and time delay. Large time delay results in larger phase delay between motion estimation and micromechanical compensation, and leads to larger uncompensated residual motion and limited bandwidth. The paper analyzes the time delay caused by image acquisition period and introduces a time delay compensation method based on SVM (Support Vector Machine) motion prediction. The main idea to cancel the time delay is to predict the current image motion from delayed measurements. A support vector machine based method is designed to predict the image motion. A prototype of stabilization imaging system has been implemented in the lab. To analyze the influences of time delay on system performance and to verify the proposed time delay cancelation method, comparative experiments over various frequencies of vibration are taken. The experimental results show that, the accuracy of motion compensation and the bandwidth of the system can be significantly improved with time delay cancelation.

  7. The direct pathway from the brainstem reticular formation to the cerebral cortex in the ascending reticular activating system: A diffusion tensor imaging study.

    PubMed

    Jang, Sung Ho; Kwon, Hyeok Gyu

    2015-10-01

    Precise evaluation of the ascending reticular activating system (ARAS) is important for diagnosis, prediction of prognosis, and management of patients with disorders of impaired consciousness. In the current study, we attempted to reconstruct the direct neural pathway between the brainstem reticular formation (RF) and the cerebral cortex in normal subjects, using diffusion tensor imaging (DTI). Forty-one healthy subjects were recruited for this study. DTIs were performed using a sensitivity-encoding head coil at 1.5Tesla with FMRIB Software Library. For connectivity of the brainstem RF, we used two regions of interest (ROIs) for the brainstem RF (seed ROI) and the thalamus and hypothalamus (exclusion ROI). Connectivity was defined as the incidence of connection between the brainstem RF and target brain regions at the threshold of 5 and 50 streamlines. Regarding the thresholds of 5 and 50, the brainstem RF showed high connectivity to the lateral prefrontal cortex (lPFC, 67.1% and 20.7%) and ventromedial prefrontal cortex (vmPFC, 50.0% and 18.3%), respectively. In contrast, the brainstem RF showed low connectivity to the primary motor cortex (31.7% and 3.7%), premotor cortex (24.4% and 3.7%), primary somatosensory cortex (23.2% and 2.4%), orbitofrontal cortex (17.1% and 7.3%), and posterior parietal cortex (12.2% and 0%), respectively. The brainstem RF was mainly connected to the prefrontal cortex, particularly lPFC and vmPFC. We believe that the methodology and results of this study would be useful to clinicians involved in the care of patients with impaired consciousness and researchers in studies of the ARAS. PMID:26363340

  8. Low-cost image analysis system

    SciTech Connect

    Lassahn, G.D.

    1995-01-01

    The author has developed an Automatic Target Recognition system based on parallel processing using transputers. This approach gives a powerful, fast image processing system at relatively low cost. This system scans multi-sensor (e.g., several infrared bands) image data to find any identifiable target, such as physical object or a type of vegetation.

  9. Image reconstruction and optimization using a terahertz scanned imaging system

    NASA Astrophysics Data System (ADS)

    Yıldırım, İhsan Ozan; Özkan, Vedat A.; Idikut, Fırat; Takan, Taylan; Şahin, Asaf B.; Altan, Hakan

    2014-10-01

    Due to the limited number of array detection architectures in the millimeter wave to terahertz region of the electromagnetic spectrum, imaging schemes with scan architectures are typically employed. In these configurations the interplay between the frequencies used to illuminate the scene and the optics used play an important role in the quality of the formed image. Using a multiplied Schottky-diode based terahertz transceiver operating at 340 GHz, in a stand-off detection scheme; the effect of image quality of a metal target was assessed based on the scanning speed of the galvanometer mirrors as well as the optical system that was constructed. Background effects such as leakage on the receiver were minimized by conditioning the signal at the output of the transceiver. Then, the image of the target was simulated based on known parameters of the optical system and the measured images were compared to the simulation. By using an image quality index based on χ2 algorithm the simulated and measured images were found to be in good agreement with a value of χ2 = 0 .14. The measurements as shown here will aid in the future development of larger stand-off imaging systems that work in the terahertz frequency range.

  10. Gimbaled multispectral imaging system and method

    DOEpatents

    Brown, Kevin H.; Crollett, Seferino; Henson, Tammy D.; Napier, Matthew; Stromberg, Peter G.

    2016-01-26

    A gimbaled multispectral imaging system and method is described herein. In an general embodiment, the gimbaled multispectral imaging system has a cross support that defines a first gimbal axis and a second gimbal axis, wherein the cross support is rotatable about the first gimbal axis. The gimbaled multispectral imaging system comprises a telescope that fixed to an upper end of the cross support, such that rotation of the cross support about the first gimbal axis causes the tilt of the telescope to alter. The gimbaled multispectral imaging system includes optics that facilitate on-gimbal detection of visible light and off-gimbal detection of infrared light.

  11. Image enhancement method for fingerprint recognition system.

    PubMed

    Li, Shunshan; Wei, Min; Tang, Haiying; Zhuang, Tiange; Buonocore, Michael

    2005-01-01

    Image enhancement plays an important role in Fingerprint Recognition System. In this paper fingerprint image enhancement method, a refined Gabor filter, is presented. This enhancement method can connect the ridge breaks, ensures the maximal gray values located at the ridge center and has the ability to compensate for the nonlinear deformations. The result shows it can improve the performance of image enhancement.

  12. Imaging Active Urokinase Plasminogen Activator in Prostate Cancer

    PubMed Central

    LeBeau, Aaron M.; Sevillano, Natalia; Markham, Kate; Winter, Michael B.; Murphy, Stephanie T.; Hostetter, Daniel R.; West, James; Lowman, Henry; Craik, Charles S.; VanBrocklin, Henry F.

    2015-01-01

    The increased proteolytic activity of membrane-bound and secreted proteases on the surface of cancer cells and in the transformed stroma is a common characteristic of aggressive metastatic prostate cancer. We describe here the development of an active site-specific probe for detecting a secreted peritumoral protease expressed by cancer cells and the surrounding tumor microenvironment. Using a human fragment antigen binding phage display library, we identified a human antibody termed U33 that selectively inhibited the active form of the protease urokinase plasminogen activator (uPA, PLAU). In the full-length immunoglobulin form, U33 IgG labeled with near-infrared fluorophores or radionuclides allowed us to non-invasively detect active uPA in prostate cancer xenograft models using optical and single-photon emission computed tomography (SPECT) imaging modalities. U33 IgG labeled with 111In had a remarkable tumor uptake of 43.2% injected dose per gram (%ID/g) 72hr post tail vein injection of the radiolabeled probe in subcutaneous xenografts. Additionally, U33 was able to image active uPA in small soft-tissue and osseous metastatic lesions using a cardiac dissemination prostate cancer model that recapitulated metastatic human cancer. The favorable imaging properties were the direct result of U33 IgG internalization through an uPA receptor mediated mechanism where U33 mimicked the function of the endogenous inhibitor of uPA to gain entry into the cancer cell. Overall, our imaging probe targets a prostate cancer-associated protease, through a unique mechanism, allowing for the non-invasive preclinical imaging of prostate cancer lesions. PMID:25672980

  13. Far Ultraviolet Imaging from the Image Spacecraft. 1; System Design

    NASA Technical Reports Server (NTRS)

    Mende, S. B.; Heetderks, H.; Frey, H. U.; Lampton, M.; Geller, S. P.; Habraken, S.; Renotte, E.; Jamar, C.; Rochus, P.; Spann, J.

    1999-01-01

    Direct imaging of the magnetosphere by the IMAGE spacecraft A,ill be supplemented by observation of the global aurora, the footprint of magnetospheric regions. To assure the simultaneity of these observations and tile measurement of the magnetospheric back-round neutral gas density, the IMAGE satellite instrument complement includes three Far Ultraviolet (FUV) instruments. In tile wavelength region 120-1 90 nm. a downward-viewing aurora imager is only minimally contaminated sunlight, scattered from clouds and ground, and radiance of the aurora observed in a nadir viewing geometry can be observed in the presence of the high-latitude day-low. Tile Wideband Imaging Camera (WIC) will provide broadband ultraviolet images of the aurora for maximum spatial and temporal resolution by imaging the LBH N2 bands of the aurora. The Spectrographic Imager (SI), a monochromatic imager, will image different types of aurora, filtered by wavelength. By measuring the Doppler-shifted Lyman-alpha, the proton-induced component of the aurora will be imaged separately. Finally, the GEO instrument will observe the distribution of the geocoronal emission, which is a measure of the neutral background density source of the charge exchange in the magnetosphere. The FUV instrument complement looks radially outward from the rotating IMAGE satellite and, therefore, it spends only a short time observing tile aurora and the Earth during, each spin. Detailed descriptions of the WIC, Si, GEO, and their individual performance validations are discussed in companion papers. This paper summarizes the system requirements and system design approach taken to satisfy the science requirements. One primary requirement is to maximize photon collection efficiency and use efficiently tile short time available foe exposures. The FUV auroral imagers WIC and SI both have wide fields of view and take data continuously as the auroral region proceeds through the field of view. To minimize data volume, multiple images

  14. Single-Camera Panoramic-Imaging Systems

    NASA Technical Reports Server (NTRS)

    Lindner, Jeffrey L.; Gilbert, John

    2007-01-01

    Panoramic detection systems (PDSs) are developmental video monitoring and image-data processing systems that, as their name indicates, acquire panoramic views. More specifically, a PDS acquires images from an approximately cylindrical field of view that surrounds an observation platform. The main subsystems and components of a basic PDS are a charge-coupled- device (CCD) video camera and lens, transfer optics, a panoramic imaging optic, a mounting cylinder, and an image-data-processing computer. The panoramic imaging optic is what makes it possible for the single video camera to image the complete cylindrical field of view; in order to image the same scene without the benefit of the panoramic imaging optic, it would be necessary to use multiple conventional video cameras, which have relatively narrow fields of view.

  15. Multicolor Imaging of Bifacial Activities of Estrogens.

    PubMed

    Kim, Sung-Bae; Umezawa, Yoshio

    2016-01-01

    The present protocol introduces multicolor imaging of bifacial activities of an estrogen. For the multicolor imaging, the authors fabricated two single-chain probes emitting green or red bioluminescence (named Simer-G and -R, respectively) from click beetle luciferase (CBLuc) green and red: Simer-R consists of the ligand binding domain of estrogen receptor (ER LBD) and the Src homology-2 (SH2) domain of Src, which are sandwiched between split-CBLuc red (CBLuc-R). On the other hand, Simer-G emitting red light consists of the ER LBD and a common consensus sequence of coactivators (LXXLL motif), which are inserted between split-CBLuc green (CBLuc-G). This probe set creates fingerprinting spectra from the characteristic green and red bioluminescence in response to agonistic and antagonistic activities of a ligand of interest. The present protocol further provides a unique methodology to calculate characteristic estrogenicity scores of various ligands from the spectra. PMID:27424902

  16. ADASY (Active Daylighting System)

    NASA Astrophysics Data System (ADS)

    Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried

    2009-08-01

    The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits

  17. Standoff concealed weapon detection using a 350 GHz radar imaging system

    SciTech Connect

    Sheen, David M.; Hall, Thomas E.; Severtsen, Ronald H.; McMakin, Douglas L.; Hatchell, Brian K.; Valdez, Patrick LJ

    2010-04-01

    The Pacific Northwest National Laboratory is currently developing a 350 GHz, active, wideband, three-dimensional, radar imaging system to evaluate the feasibility of active sub-mm imaging for standoff concealed weapon detection. The prototype radar imaging system is based on a wideband, heterodyne, frequency-multiplier-based transceiver system coupled to a quasi-optical focusing system and high-speed rotating conical scanner. The wideband operation of this system provides accurate ranging information, and the images obtained are fully three-dimensional. Recent improvements to the system include increased imaging speed using improved balancing techniques, wider bandwidth, and image display techniques.

  18. Video imaging of cardiac transmembrane activity

    NASA Astrophysics Data System (ADS)

    Baxter, William T.; Davidenko, Jorge; Cabo, Candido; Jalife, Jose

    1994-05-01

    High resolution movies of transmembrane electrical activity in thin (0.5 mm) slices of sheep epicardial muscle were recorded by optical imaging with voltage-sensitive dyes and a CCD video camera. Activity was monitored at approximately 65,000 picture elements per 2 cm2 tissue for several seconds at a 16 msec sampling rate. Simple image processing operations permitted visualization and analysis of the optical signal, while isochrome maps depicted complex patterns of propagation. Maps of action potential duration and regional intermittent conduction block showed that even these small preparations may exhibit considerable spatial heterogeneity. Self-sustaining reentrant activity in the form of spiral waves was consistently initiated and observed either drifting across the tissue or anchored to small heterogeneities. The current limitations of video optical mappings are a low signal-to- noise ratio and low temporal resolution. The advantages include high spatial resolution and direct correlation of electrical activity with anatomy. Video optical mapping permits the analysis of the electrophysiological properties of any region of the preparation during both regular stimulation and reentrant activation, providing a useful tool for studying cardiac arrhythmias.

  19. Special feature on imaging systems and techniques

    NASA Astrophysics Data System (ADS)

    Yang, Wuqiang; Giakos, George

    2013-07-01

    The IEEE International Conference on Imaging Systems and Techniques (IST'2012) was held in Manchester, UK, on 16-17 July 2012. The participants came from 26 countries or regions: Austria, Brazil, Canada, China, Denmark, France, Germany, Greece, India, Iran, Iraq, Italy, Japan, Korea, Latvia, Malaysia, Norway, Poland, Portugal, Sweden, Switzerland, Taiwan, Tunisia, UAE, UK and USA. The technical program of the conference consisted of a series of scientific and technical sessions, exploring physical principles, engineering and applications of new imaging systems and techniques, as reflected by the diversity of the submitted papers. Following a rigorous review process, a total of 123 papers were accepted, and they were organized into 30 oral presentation sessions and a poster session. In addition, six invited keynotes were arranged. The conference not only provided the participants with a unique opportunity to exchange ideas and disseminate research outcomes but also paved a way to establish global collaboration. Following the IST'2012, a total of 55 papers, which were technically extended substantially from their versions in the conference proceeding, were submitted as regular papers to this special feature of Measurement Science and Technology . Following a rigorous reviewing process, 25 papers have been finally accepted for publication in this special feature and they are organized into three categories: (1) industrial tomography, (2) imaging systems and techniques and (3) image processing. These papers not only present the latest developments in the field of imaging systems and techniques but also offer potential solutions to existing problems. We hope that this special feature provides a good reference for researchers who are active in the field and will serve as a catalyst to trigger further research. It has been our great pleasure to be the guest editors of this special feature. We would like to thank the authors for their contributions, without which it would

  20. Phase transfer function of digital imaging systems

    NASA Astrophysics Data System (ADS)

    Bhakta, Vikrant R.

    For the past several decades, optical engineering has relied heavily on Fourier analysis of linear systems as a valuable aid in realizing numerous imaging applications. Today, spatial frequency analysis via the optical transfer function (OTF) remains an integral tool for the design, characterization and testing of incoherent imaging systems. The magnitude of the complex OTF is known as the modulation transfer function (MTF) and its phase is given by the phase transfer function (PTF). The MTF represents the contrast reduction at each spatial frequency; whereas, the PTF represents the spatial shift of these frequencies. While the MTF has been used extensively to characterize imaging systems, the PTF has long been ignored because it was thought to have an insignificant presence and to be difficult to understand and measure. Through theoretical analysis and experimental demonstrations, this work addresses all of these issues and shows that the PTF is a valuable tool for modern-day digital imaging systems. The effects of optical aberrations on the PTF of an imaging system in the absence of aliasing have been analyzed in detail. However, for the digital imaging systems, the effect of aliasing on the overall system behavior becomes an important consideration. To this end, the effects of aliasing on the PTF of the sampled imaging system are described and its key properties are derived. The role of PTF as an essential metric in today's imaging systems necessitates practical PTF measurement techniques. Two, easy-to-implement, image-based methods for PTF measurement are described and experimentally validated. These measurement methods and the insights gained from the theoretical analysis are leveraged for several applications spanning diverse fields such as optical system characterization, computational imaging, and image processing.

  1. Active vision and image/video understanding systems built upon network-symbolic models for perception-based navigation of mobile robots in real-world environments

    NASA Astrophysics Data System (ADS)

    Kuvich, Gary

    2004-12-01

    To be completely successful, robots need to have reliable perceptual systems that are similar to human vision. It is hard to use geometric operations for processing of natural images. Instead, the brain builds a relational network-symbolic structure of visual scene, using different clues to set up the relational order of surfaces and objects with respect to the observer and to each other. Feature, symbol, and predicate are equivalent in the biologically inspired Network-Symbolic systems. A linking mechanism binds these features/symbols into coherent structures, and image converts from a "raster" into a "vector" representation. View-based object recognition is a hard problem for traditional algorithms that directly match a primary view of an object to a model. In Network-Symbolic Models, the derived structure, not the primary view, is a subject for recognition. Such recognition is not affected by local changes and appearances of the object as seen from a set of similar views. Once built, the model of visual scene changes slower then local information in the visual buffer. It allows for disambiguating visual information and effective control of actions and navigation via incremental relational changes in visual buffer. Network-Symbolic models can be seamlessly integrated into the NIST 4D/RCS architecture and better interpret images/video for situation awareness, target recognition, navigation and actions.

  2. Compton Dry-Cask Imaging System

    ScienceCinema

    None

    2016-07-12

    The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

  3. Compton Dry-Cask Imaging System

    SciTech Connect

    2011-01-01

    The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

  4. Fidelity Analysis of Sampled Imaging Systems

    NASA Technical Reports Server (NTRS)

    Park, Stephen K.; Rahman, Zia-ur

    1999-01-01

    Many modeling, simulation and performance analysis studies of sampled imaging systems are inherently incomplete because they are conditioned on a discrete-input, discrete-output model that only accounts for blurring during image acquisition and additive noise. For those sampled imaging systems where the effects of digital image acquisition, digital filtering and reconstruction are significant, the modeling, simulation and performance analysis should be based on a more comprehensive continuous-input, discrete-processing, continuous-output end-to-end model. This more comprehensive model should properly account for the low-pass filtering effects of image acquisition prior to sampling, the potentially important noiselike effects of the aliasing caused by sampling, additive noise due to device electronics and quantization, the generally high-boost filtering effects of digital processing, and the low-pass filtering effects of image reconstruction. This model should not, however, be so complex as to preclude significant mathematical analysis, particularly the mean-square (fidelity) type of analysis so common in linear system theory. We demonstrate that, although the mathematics of such a model is more complex, the increase in complexity is not so great as to prevent a complete fidelity-metric analysis at both the component level and at the end-to-end system level: that is, computable mean-square-based fidelity metrics are developed by which both component-level and system-level performance can be quantified. In addition, we demonstrate that system performance can be assessed qualitatively by visualizing the output image as the sum of three component images, each of which relates to a corresponding fidelity metric. The cascaded, or filtered, component accounts for the end-to-end system filtering of image acquisition, digital processing, and image reconstruction; the random noise component accounts for additive random noise, modulated by digital processing and image

  5. Fiber optic in vivo imaging in the mammalian nervous system

    PubMed Central

    Mehta, Amit D; Jung, Juergen C; Flusberg, Benjamin A; Schnitzer, Mark J

    2010-01-01

    The compact size, mechanical flexibility, and growing functionality of optical fiber and fiber optic devices are enabling several new modalities for imaging the mammalian nervous system in vivo. Fluorescence microendoscopy is a minimally invasive fiber modality that provides cellular resolution in deep brain areas. Diffuse optical tomography is a non-invasive modality that uses assemblies of fiber optic emitters and detectors on the cranium for volumetric imaging of brain activation. Optical coherence tomography is a sensitive interferometric imaging technique that can be implemented in a variety of fiber based formats and that might allow intrinsic optical detection of brain activity at a high resolution. Miniaturized fiber optic microscopy permits cellular level imaging in the brains of behaving animals. Together, these modalities will enable new uses of imaging in the intact nervous system for both research and clinical applications. PMID:15464896

  6. Detection performance of laser range-gated imaging system

    NASA Astrophysics Data System (ADS)

    Xu, Jun; Li, Xiaofeng; Luo, Jijun; Zhang, Shengxiu; Xu, Yibin

    2010-10-01

    Laser radar is rapidly developing towards very capable sensors for number of applications such as military sensing and guidance, auto collision avoidance, robotic vision and atmospheric sensing. In this paper, the detection performance of non-scanned Laser Rang-gated (LRG) imaging system is studied. In order to compute the detection range of laser active imaging system, the range equation is derived by using laser illuminating model and considering factors which affect system imaging quality. According to the principle of laser radar and the characters of objects and the detectors in special applied setting, it mainly deduced the non-scanned laser radar range equation of the range-gated system, meanwhile, the SNR model of non-scanned LRG imaging system is set up. Then, relationship of the detection probability, the false alarm probability and the signal-to-noise ratio in the non-scanned LRG imaging system are analyzed, the influence factors of system's performance are pointed out, and the solution is proposed. The detection performance simulation software of non-scanned LRG imaging system is designed with MATLAB and the performance of the imaging system is simulated.

  7. Automated imaging system for single molecules

    DOEpatents

    Schwartz, David Charles; Runnheim, Rodney; Forrest, Daniel

    2012-09-18

    There is provided a high throughput automated single molecule image collection and processing system that requires minimal initial user input. The unique features embodied in the present disclosure allow automated collection and initial processing of optical images of single molecules and their assemblies. Correct focus may be automatically maintained while images are collected. Uneven illumination in fluorescence microscopy is accounted for, and an overall robust imaging operation is provided yielding individual images prepared for further processing in external systems. Embodiments described herein are useful in studies of any macromolecules such as DNA, RNA, peptides and proteins. The automated image collection and processing system and method of same may be implemented and deployed over a computer network, and may be ergonomically optimized to facilitate user interaction.

  8. 3D holoscopic video imaging system

    NASA Astrophysics Data System (ADS)

    Steurer, Johannes H.; Pesch, Matthias; Hahne, Christopher

    2012-03-01

    Since many years, integral imaging has been discussed as a technique to overcome the limitations of standard still photography imaging systems where a three-dimensional scene is irrevocably projected onto two dimensions. With the success of 3D stereoscopic movies, a huge interest in capturing three-dimensional motion picture scenes has been generated. In this paper, we present a test bench integral imaging camera system aiming to tailor the methods of light field imaging towards capturing integral 3D motion picture content. We estimate the hardware requirements needed to generate high quality 3D holoscopic images and show a prototype camera setup that allows us to study these requirements using existing technology. The necessary steps that are involved in the calibration of the system as well as the technique of generating human readable holoscopic images from the recorded data are discussed.

  9. Human factors in automatic image retrieval system design and evaluation

    NASA Astrophysics Data System (ADS)

    Jaimes, Alejandro

    2006-01-01

    Image retrieval is a human-centered task: images are created by people and are ultimately accessed and used by people for human-related activities. In designing image retrieval systems and algorithms, or measuring their performance, it is therefore imperative to consider the conditions that surround both the indexing of image content and the retrieval. This includes examining the different levels of interpretation for retrieval, possible search strategies, and image uses. Furthermore, we must consider different levels of similarity and the role of human factors such as culture, memory, and personal context. This paper takes a human-centered perspective in outlining levels of description, types of users, search strategies, image uses, and human factors that affect the construction and evaluation of automatic content-based retrieval systems, such as human memory, context, and subjectivity.

  10. Neutron activation analysis system

    DOEpatents

    Taylor, M.C.; Rhodes, J.R.

    1973-12-25

    A neutron activation analysis system for monitoring a generally fluid media, such as slurries, solutions, and fluidized powders, including two separate conduit loops for circulating fluid samples within the range of radiation sources and detectors is described. Associated with the first loop is a neutron source that emits s high flux of slow and thermal neutrons. The second loop employs a fast neutron source, the flux from which is substantially free of thermal neutrons. Adjacent to both loops are gamma counters for spectrographic determination of the fluid constituents. Other gsmma sources and detectors are arranged across a portion of each loop for deterMining the fluid density. (Official Gazette)

  11. Imaging the Glycome in Living Systems

    PubMed Central

    Li, Boyangzi; Mock, Feiyan; Wu, Peng

    2016-01-01

    The glycome, the full complement of glycans that cells produce, is an attractive target for molecular imaging. Imaging of the glycome in living systems has recently been enabled via bioorthogonal chemical reporter-based approaches. In this chapter, we describe two approaches to introduce bioorthogonal chemical reporters (tags) onto cell surface fucosylated glycans and glycans bearing LacNAc disaccharides, respectively. The tagged glycans can then be conjugated to imaging probes via bioorthogonal click chemistry. Similar approaches can be extended to image other sectors of the glycome in living systems. PMID:22289465

  12. Modified pressure system for imaging egg cracks

    NASA Astrophysics Data System (ADS)

    Lawrence, Kurt C.; Yoon, Seung Chul; Jones, Deana R.; Heitschmidt, Gerald W.; Park, Bosoon; Windham, William R.

    2008-04-01

    One aspect of grading table eggs is shell checks or cracks. Currently, USDA voluntary regulations require that humans grade a representative sample of all eggs processed. However, as processing plants and packing facilities continue to increase their volume and throughput, human graders are having difficulty matching the pace of the machines. Additionally, some plants also have a problem with micro-cracks that the graders often miss because they are very small and hard to see immediately post-processing but grow and become readily apparent before they reach market. An imaging system was developed to help the grader detect these small micro-cracks. The imaging system utilized one image captured at atmospheric pressure and a second at a slight negative pressure to enhance the crack and make detection much easier. A simple image processing algorithm was then applied to the ratio of these two images and the resulting image, containing both cracked and/or intact eggs were color-coded to simplify identification. The imaging system was capable of imaging 15 eggs in about 3/4 second and the algorithm processing took about another 10 seconds. These times could easily be reduced with a dedicated, multi-threaded computer program. In analyzing 1000 eggs, the system was 99.6% accurate overall with only 0.3% false positives compared to 94.2% accurate overall for the human graders with 1.2% false positives. An international patent on the system was filed and further automation of the system is needed.

  13. Terahertz imaging system with resonant tunneling diodes

    NASA Astrophysics Data System (ADS)

    Miyamoto, Tomoyuki; Yamaguchi, Atsushi; Mukai, Toshikazu

    2016-03-01

    We report a feasibility study of a terahertz imaging system with resonant tunneling diodes (RTDs) that oscillate at 0.30 THz. A pair of RTDs acted as an emitter and a detector in the system. Terahertz reflection images of opaque samples were acquired with our RTD imaging system. A spatial resolution of 1 mm, which is equal to the wavelength of the RTD emitter, was achieved. The signal-to-noise ratio (SNR) of the reflection image was improved by 6 dB by using polarization optics that reduced interference effects. Additionally, the coherence of the RTD enabled a depth resolution of less than 3 µm to be achieved by an interferometric technique. Thus, RTDs are an attractive candidate for use in small THz imaging systems.

  14. Active Metamaterials for Terahertz Communication and Imaging

    NASA Astrophysics Data System (ADS)

    Rout, Saroj

    In recent years there has been significant interest in terahertz (THz) systems mostly due to their unique applications in communication and imaging. One of the primary reason for this resurgence is the use of metamaterials to design THz devices due to lack of natural materials that can respond to this electromagnetic spectrum, the so-called ''THz gap''. Even after years of intense research, THz systems are complex and expensive, unsuitable for mainstream applications. This work focuses on bridging this gap by building all solid-state THz devices for imaging and communication applications in a commercial integrated circuit (IC) technology. One such canonical device is a THz wave modulator that can be used in THz wireless communication devices and as spatial light modulator (SLM) for THz imaging systems. The key contribution of this thesis is a metamaterial based THz wave modulator fabricated in a commercial gallium arsenide (GaAs) process resonant at 0.46 THz using a novel approach of embedding pseudomorphic high electron mobility transistors (pHEMTs) in metamaterial and demonstrate modulation values over 30%, and THz modulation at frequencies up to 10 MHz. Using the THz wave modulator, we fabricated and experimentally demonstrated an all solid-state metamaterial based THz spatial light modulator (SLM) as a 2x2 pixel array operating around 0.46 THz, by raster scanning an occluded metal object in polystyrene using a single-pixel imaging setup. This was an important step towards building an low-voltage (1V), low power, on-chip integrable THz imaging device. Using the characterization result from the THz SLM, we computationally demonstrated a multi-level amplitude shift keying (ASK) terahertz wireless communication system using spatial light modulation instead of traditional voltage mode modulation, achieving higher spectral efficiency for high speed communication. We show two orders of magnitude improvement in symbol error rate (SER) for a degradation of 20 dB in

  15. Image informatics in systems biology applications

    NASA Astrophysics Data System (ADS)

    Wong, Stephen T. C.

    2005-02-01

    Digital optical microscopy, coupled with parallel processing and a large arsenal of labeling techniques, offers tremendous values to localize, identify, and characterize cells and molecules. This generates many image informatics challenges in requiring new algorithms and tools to extract, classify, correlate, and model image features and content from massive amounts of cellular and molecular images acquired. Image informatics aims to fill this gap. Coupling automated microscopy and image analysis with biostatistical and data mining techniques to provide a system biologic approach in studying the cells, the basic unit of life, potentially leads to many exciting applications in life and health sciences. In this presentation, we describe certain new system biology applications enabled by image informatics technology.

  16. Imaging characteristics of photogrammetric camera systems

    USGS Publications Warehouse

    Welch, R.; Halliday, J.

    1973-01-01

    In view of the current interest in high-altitude and space photographic systems for photogrammetric mapping, the United States Geological Survey (U.S.G.S.) undertook a comprehensive research project designed to explore the practical aspects of applying the latest image quality evaluation techniques to the analysis of such systems. The project had two direct objectives: (1) to evaluate the imaging characteristics of current U.S.G.S. photogrammetric camera systems; and (2) to develop methodologies for predicting the imaging capabilities of photogrammetric camera systems, comparing conventional systems with new or different types of systems, and analyzing the image quality of photographs. Image quality was judged in terms of a number of evaluation factors including response functions, resolving power, and the detectability and measurability of small detail. The limiting capabilities of the U.S.G.S. 6-inch and 12-inch focal length camera systems were established by analyzing laboratory and aerial photographs in terms of these evaluation factors. In the process, the contributing effects of relevant parameters such as lens aberrations, lens aperture, shutter function, image motion, film type, and target contrast procedures for analyzing image quality and predicting and comparing performance capabilities. ?? 1973.

  17. Design Criteria For Networked Image Analysis System

    NASA Astrophysics Data System (ADS)

    Reader, Cliff; Nitteberg, Alan

    1982-01-01

    Image systems design is currently undergoing a metamorphosis from the conventional computing systems of the past into a new generation of special purpose designs. This change is motivated by several factors, notably among which is the increased opportunity for high performance with low cost offered by advances in semiconductor technology. Another key issue is a maturing in understanding of problems and the applicability of digital processing techniques. These factors allow the design of cost-effective systems that are functionally dedicated to specific applications and used in a utilitarian fashion. Following an overview of the above stated issues, the paper presents a top-down approach to the design of networked image analysis systems. The requirements for such a system are presented, with orientation toward the hospital environment. The three main areas are image data base management, viewing of image data and image data processing. This is followed by a survey of the current state of the art, covering image display systems, data base techniques, communications networks and software systems control. The paper concludes with a description of the functional subystems and architectural framework for networked image analysis in a production environment.

  18. AMISS - Active and passive MIcrowaves for Security and Subsurface imaging

    NASA Astrophysics Data System (ADS)

    Soldovieri, Francesco; Slob, Evert; Turk, Ahmet Serdar; Crocco, Lorenzo; Catapano, Ilaria; Di Matteo, Francesca

    2013-04-01

    The FP7-IRSES project AMISS - Active and passive MIcrowaves for Security and Subsurface imaging is based on a well-combined network among research institutions of EU, Associate and Third Countries (National Research Council of Italy - Italy, Technische Universiteit Delft - The Netherlands, Yildiz Technical University - Turkey, Bauman Moscow State Technical University - Russia, Usikov Institute for Radio-physics and Electronics and State Research Centre of Superconductive Radioelectronics "Iceberg" - Ukraine and University of Sao Paulo - Brazil) with the aims of achieving scientific advances in the framework of microwave and millimeter imaging systems and techniques for security and safety social issues. In particular, the involved partners are leaders in the scientific areas of passive and active imaging and are sharing their complementary knowledge to address two main research lines. The first one regards the design, characterization and performance evaluation of new passive and active microwave devices, sensors and measurement set-ups able to mitigate clutter and increase information content. The second line faces the requirements to make State-of-the-Art processing tools compliant with the instrumentations developed in the first line, suitable to work in electromagnetically complex scenarios and able to exploit the unexplored possibilities offered by new instrumentations. The main goals of the project are: 1) Development/improvement and characterization of new sensors and systems for active and passive microwave imaging; 2) Set up, analysis and validation of state of art/novel data processing approach for GPR in critical infrastructure and subsurface imaging; 3) Integration of state of art and novel imaging hardware and characterization approaches to tackle realistic situations in security, safety and subsurface prospecting applications; 4) Development and feasibility study of bio-radar technology (system and data processing) for vital signs detection and

  19. Electromagnetic imaging of dynamic brain activity

    SciTech Connect

    Mosher, J.; Leahy, R. . Dept. of Electrical Engineering); Lewis, P.; Lewine, J.; George, J. ); Singh, M. . Dept. of Radiology)

    1991-01-01

    Neural activity in the brain produces weak dynamic electromagnetic fields that can be measured by an array of sensors. Using a spatio-temporal modeling framework, we have developed a new approach to localization of multiple neural sources. This approach is based on the MUSIC algorithm originally developed for estimating the direction of arrival of signals impinging on a sensor array. We present applications of this technique to magnetic field measurements of a phantom and of a human evoked somatosensory response. The results of the somatosensory localization are mapped onto the brain anatomy obtained from magnetic resonance images.

  20. Electromagnetic imaging of dynamic brain activity

    SciTech Connect

    Mosher, J.; Leahy, R.; Lewis, P.; Lewine, J.; George, J.; Singh, M.

    1991-12-31

    Neural activity in the brain produces weak dynamic electromagnetic fields that can be measured by an array of sensors. Using a spatio-temporal modeling framework, we have developed a new approach to localization of multiple neural sources. This approach is based on the MUSIC algorithm originally developed for estimating the direction of arrival of signals impinging on a sensor array. We present applications of this technique to magnetic field measurements of a phantom and of a human evoked somatosensory response. The results of the somatosensory localization are mapped onto the brain anatomy obtained from magnetic resonance images.

  1. The VST active primary mirror support system

    NASA Astrophysics Data System (ADS)

    Schipani, Pietro; Capaccioli, Massimo; D'Orsi, Sergio; Ferragina, Luigi; Marty, Laurent; Molfese, Cesare; Perrotta, Francesco; De Paris, Giacinto; Fierro, Davide; Tomelleri, Raffaele; Rossettini, Pierfrancesco; Perina, Francesco; Recchia, Stefano; Magrin, Demetrio

    2010-07-01

    The 2.6-m primary mirror of the VST telescope is equipped with an active optics system in order to correct low-order aberrations, constantly monitoring the optical quality of the image and controlling the relative position and the shape of the optical elements. Periodically an image analyser calculates the deviation of the image from the best quality. VST is equipped with both a Shack-Hartmann in the probe system and a curvature sensor embedded in the OmegaCAM instrument. The telescope control software decomposes the deviation into single optical contributions and calculates the force correction that each active element has to perform to achieve the optimal quality. The set of correction forces, one for each axial actuator, is computed by the telescope central computer and transmitted to the local control unit of the primary mirror system for execution. The most important element of the VST active optics is the primary mirror, with its active support system located within the primary mirror cell structure. The primary mirror support system is composed by an axial and a lateral independent systems and includes an earthquake safety system. The system is described and the results of the qualification test campaign are discussed.

  2. European Neutron Activation System.

    2013-01-11

    Version 03 EASY-2010 (European Activation System) consists of a wide range of codes, data and documentation all aimed at satisfying the objective of calculating the response of materials irradiated in a neutron flux. The main difference from the previous version is the upper energy limit, which has increased from 20 to 60 MeV. It is designed to investigate both fusion devices and accelerator based materials test facilities that will act as intense sources of high-energymore » neutrons causing significant activation of the surrounding materials. The very general nature of the calculational method and the data libraries means that it is applicable (with some reservations) to all situations (e.g. fission reactors or neutron sources) where materials are exposed to neutrons below 60 MeV. EASY can be divided into two parts: data and code development tools and user tools and data. The former are required to develop the latter, but EASY users only need to be able to use the inventory code FISPACT and be aware of the contents of the EAF library (the data source). The complete EASY package contains the FISPACT-2007 inventory code, the EAF-2003, EAF-2005, EAF-2007 and EAF-2010 libraries, and the EASY User Interface for the Window version. The activation package EASY-2010 is the result of significant development to extend the upper energy range from 20 to 60 MeV so that it is capable of being used for IFMIF calculations. The EAF-2010 library contains 66,256 reactions, almost five times more than in EAF-2003 (12,617). Deuteron-induced and proton-induced cross section libraries are also included, and can be used with EASY to enable calculations of the activation due to deuterons and proton [2].« less

  3. Scanned Image Projection System Employing Intermediate Image Plane

    NASA Technical Reports Server (NTRS)

    DeJong, Christian Dean (Inventor); Hudman, Joshua M. (Inventor)

    2014-01-01

    In imaging system, a spatial light modulator is configured to produce images by scanning a plurality light beams. A first optical element is configured to cause the plurality of light beams to converge along an optical path defined between the first optical element and the spatial light modulator. A second optical element is disposed between the spatial light modulator and a waveguide. The first optical element and the spatial light modulator are arranged such that an image plane is created between the spatial light modulator and the second optical element. The second optical element is configured to collect the diverging light from the image plane and collimate it. The second optical element then delivers the collimated light to a pupil at an input of the waveguide.

  4. CMAS: a rich media annotation system for medical imaging

    NASA Astrophysics Data System (ADS)

    Lin, I.-Jong; Chao, Hui

    2006-03-01

    We have developed the CMAS system (Collaborative Medical Annotation System) so that medical professionals will be able to easily annotate digital medical records that contain medical imaging or procedure videos. The CMAS system enables a non-technical person to annotate a medical image or video with their recorded presence. The CMAS system displays medical images via a projector onto a screen; when a doctor (or patient) physically walks in front of this screen with the medical image and gives his/her opinion while gesturing at the image, the CMAS system intuitively captures this interaction by creating a video annotation with HP's Active Shadows technology. The CMAS system automatically transforms physical interactions, ranging from a laser pointer spot to a doctor's physical presence, into video annotation that then can be overlaid on top of the medical image or seamlessly inserted into the procedure video. Annotated in such a manner, the medical record retains the historical development of the diagnostic medical opinion, explained through presence of doctors and their respective annotations. The CMAS system structures the annotation of digital medical records such that image/video annotations from multiple sources, at different times, and from different locations can be maintained within a historical context and be consistently referenced among multiple annotations.

  5. An Automated Imaging System for Radiation Biodosimetry

    PubMed Central

    Garty, Guy; Bigelow, Alan W.; Repin, Mikhail; Turner, Helen C.; Bian, Dakai; Balajee, Adayabalam S.; Lyulko, Oleksandra V.; Taveras, Maria; Yao, Y. Lawrence; Brenner, David J.

    2015-01-01

    We describe here an automated imaging system developed at the Center for High Throughput Minimally Invasive Radiation Biodosimetry. The imaging system is built around a fast, sensitive sCMOS camera and rapid switchable LED light source. It features complete automation of all the steps of the imaging process and contains built-in feedback loops to ensure proper operation. The imaging system is intended as a back end to the RABiT – a robotic platform for radiation biodosimetry. It is intended to automate image acquisition and analysis for four biodosimetry assays for which we have developed automated protocols: The Cytokinesis Blocked Micronucleus assay, the γ-H2AX assay, the Dicentric assay (using PNA or FISH probes) and the RABiT-BAND assay. PMID:25939519

  6. Hyperspectral imaging utility for transportation systems

    NASA Astrophysics Data System (ADS)

    Bridgelall, Raj; Rafert, J. Bruce; Tolliver, Denver

    2015-03-01

    The global transportation system is massive, open, and dynamic. Existing performance and condition assessments of the complex interacting networks of roadways, bridges, railroads, pipelines, waterways, airways, and intermodal ports are expensive. Hyperspectral imaging is an emerging remote sensing technique for the non-destructive evaluation of multimodal transportation infrastructure. Unlike panchromatic, color, and infrared imaging, each layer of a hyperspectral image pixel records reflectance intensity from one of dozens or hundreds of relatively narrow wavelength bands that span a broad range of the electromagnetic spectrum. Hence, every pixel of a hyperspectral scene provides a unique spectral signature that offers new opportunities for informed decision-making in transportation systems development, operations, and maintenance. Spaceborne systems capture images of vast areas in a short period but provide lower spatial resolution than airborne systems. Practitioners use manned aircraft to achieve higher spatial and spectral resolution, but at the price of custom missions and narrow focus. The rapid size and cost reduction of unmanned aircraft systems promise a third alternative that offers hybrid benefits at affordable prices by conducting multiple parallel missions. This research formulates a theoretical framework for a pushbroom type of hyperspectral imaging system on each type of data acquisition platform. The study then applies the framework to assess the relative potential utility of hyperspectral imaging for previously proposed remote sensing applications in transportation. The authors also introduce and suggest new potential applications of hyperspectral imaging in transportation asset management, network performance evaluation, and risk assessments to enable effective and objective decision- and policy-making.

  7. Ultrasonic flow imaging system: A feasibility study

    SciTech Connect

    Sheen, S.H.; Lawrence, W.P.; Chien, H.T.; Raptis, A.C.

    1991-09-01

    This report examines the feasibility and potential problems in developing a real-time ultrasonic flow imaging instrument for on-line monitoring of mixed-phased flows such as coal slurries. State-of-the-art ultrasonic imaging techniques are assessed for this application. Reflection and diffraction tomographies are proposed for further development, including image-reconstruction algorithms and parallel processing systems. A conventional ultrasonic C-scan technique is used to demonstrate the feasibility of imaging the particle motion in a solid/water flow. 13 refs., 11 figs.

  8. Linear and non-linear fluorescence imaging of neuronal activity

    NASA Astrophysics Data System (ADS)

    Fisher, Jonathan A. N.

    Optical imaging of neuronal activity offers new possibilities for understanding brain physiology. The predominant methods in neuroscience for measuring electrical activity require electrodes inserted into the tissue. Such methods, however, provide limited spatial information and are invasive. Optical methods are less physically invasive and offer the possibility for simultaneously imaging the activity of many neurons. In this thesis one- and two-photon fluorescence microscopy techniques were applied to several in vivo and in vitro mammalian preparations. Using one-photon absorption fluorescence microscopy and gradient index (GRIN) lens optics, cortical electrical activity in response to electric stimulation was resolved in three-dimensions at high-speed in the primary somatosensory cortex of the mouse in vivo using voltage-sensitive dyes. Imaging at depths up to 150 mum below the cortex surface, it was possible to resolve depth-dependent patterns of neuronal activity in response to cortical and thalamic electric stimulation. The patterns of activity were consistent with known cortical cellular architecture. In a qualitatively different set of experiments, one-photon fluorescence microscopy via voltage-sensitive dyes was successfully employed to image an in vitro preparation of the perfused rat brainstem during the process of respiratory rhythmogenesis. Imaging results yielded insights into the spatial organization of the central respiratory rhythm generation region in the ventrolateral medulla. A multifocal two-photon scanning microscope was constructed, and design and operation principles are described. Utilizing the novel device, anatomical and functional two-photon imaging via potentiometric dyes and calcium dyes is described, and the results of in vivo versus in vitro imaging are compared. Anatomical imaging results used either functional probe background fluorescence or green fluorescent protein (GFP) expression. Spectroscopic experiments measuring the two

  9. FLIPS: Friendly Lisp Image Processing System

    NASA Astrophysics Data System (ADS)

    Gee, Shirley J.

    1991-08-01

    The Friendly Lisp Image Processing System (FLIPS) is the interface to Advanced Target Detection (ATD), a multi-resolutional image analysis system developed by Hughes in conjunction with the Hughes Research Laboratories. Both menu- and graphics-driven, FLIPS enhances system usability by supporting the interactive nature of research and development. Although much progress has been made, fully automated image understanding technology that is both robust and reliable is not a reality. In situations where highly accurate results are required, skilled human analysts must still verify the findings of these systems. Furthermore, the systems often require processing times several orders of magnitude greater than that needed by veteran personnel to analyze the same image. The purpose of FLIPS is to facilitate the ability of an image analyst to take statistical measurements on digital imagery in a timely fashion, a capability critical in research environments where a large percentage of time is expended in algorithm development. In many cases, this entails minor modifications or code tinkering. Without a well-developed man-machine interface, throughput is unduly constricted. FLIPS provides mechanisms which support rapid prototyping for ATD. This paper examines the ATD/FLIPS system. The philosophy of ATD in addressing image understanding problems is described, and the capabilities of FLIPS are discussed, along with a description of the interaction between ATD and FLIPS. Finally, an overview of current plans for the system is outlined.

  10. Preliminary investigations of active pixel sensors in Nuclear Medicine imaging

    NASA Astrophysics Data System (ADS)

    Ott, Robert; Evans, Noel; Evans, Phil; Osmond, J.; Clark, A.; Turchetta, R.

    2009-06-01

    Three CMOS active pixel sensors have been investigated for their application to Nuclear Medicine imaging. Startracker with 525×525 25 μm square pixels has been coupled via a fibre optic stud to a 2 mm thick segmented CsI(Tl) crystal. Imaging tests were performed using 99mTc sources, which emit 140 keV gamma rays. The system was interfaced to a PC via FPGA-based DAQ and optical link enabling imaging rates of 10 f/s. System noise was measured to be >100e and it was shown that the majority of this noise was fixed pattern in nature. The intrinsic spatial resolution was measured to be ˜80 μm and the system spatial resolution measured with a slit was ˜450 μm. The second sensor, On Pixel Intelligent CMOS (OPIC), had 64×72 40 μm pixels and was used to evaluate noise characteristics and to develop a method of differentiation between fixed pattern and statistical noise. The third sensor, Vanilla, had 520×520 25 μm pixels and a measured system noise of ˜25e. This sensor was coupled directly to the segmented phosphor. Imaging results show that even at this lower level of noise the signal from 140 keV gamma rays is small as the light from the phosphor is spread over a large number of pixels. Suggestions for the 'ideal' sensor are made.

  11. Portable EDITOR (PEDITOR): A portable image processing system. [satellite images

    NASA Technical Reports Server (NTRS)

    Angelici, G.; Slye, R.; Ozga, M.; Ritter, P.

    1986-01-01

    The PEDITOR image processing system was created to be readily transferable from one type of computer system to another. While nearly identical in function and operation to its predecessor, EDITOR, PEDITOR employs additional techniques which greatly enhance its portability. These cover system structure and processing. In order to confirm the portability of the software system, two different types of computer systems running greatly differing operating systems were used as target machines. A DEC-20 computer running the TOPS-20 operating system and using a Pascal Compiler was utilized for initial code development. The remaining programmers used a Motorola Corporation 68000-based Forward Technology FT-3000 supermicrocomputer running the UNIX-based XENIX operating system and using the Silicon Valley Software Pascal compiler and the XENIX C compiler for their initial code development.

  12. Portable imaging system method and apparatus

    DOEpatents

    Freifeld, Barry M.; Kneafsley, Timothy J.; Pruess, Jacob; Tomutsa, Liviu; Reiter, Paul A.; deCastro, Ted M.

    2006-07-25

    An operator shielded X-ray imaging system has sufficiently low mass (less than 300 kg) and is compact enough to enable portability by reducing operator shielding requirements to a minimum shielded volume. The resultant shielded volume may require a relatively small mass of shielding in addition to the already integrally shielded X-ray source, intensifier, and detector. The system is suitable for portable imaging of well cores at remotely located well drilling sites. The system accommodates either small samples, or small cross-sectioned objects of unlimited length. By rotating samples relative to the imaging device, the information required for computer aided tomographic reconstruction may be obtained. By further translating the samples relative to the imaging system, fully three dimensional (3D) tomographic reconstructions may be obtained of samples having arbitrary length.

  13. Imaging Systemic Dysfunction in Parkinson's Disease.

    PubMed

    Borghammer, Per; Knudsen, Karoline; Brooks, David J

    2016-06-01

    Parkinson's disease is now widely recognized to be a multisystem disorder affecting the brain and peripheral autonomic nerves. Extensive pathology is present in both the sympathetic and parasympathetic nervous system and the intrinsic gastrointestinal plexuses in patients. Autonomic pathology and symptoms such as constipation can predate the clinical diagnosis by years or decades. Imaging studies have contributed greatly to our understanding of Parkinson's disease but focused primarily on imaging cerebral pathology. However, given the importance of understanding the nature, chronology, and functional consequences of peripheral pathology, there has been renewed interest in imaging peripheral organs in Parkinson's disease. Suitable imaging tools can be divided into two types: radiotracer studies that directly estimate loss of sympathetic or parasympathetic nerve terminals, and imaging modalities to quantitate dysphagia, gastric emptying, esophageal and intestinal transit times, and anorectal dyssynergia. In this review, we summarize current knowledge about peripheral imaging in Parkinson's disease. PMID:27072951

  14. Imaging Spectrometry-Concepts and System Tradeoffs

    NASA Technical Reports Server (NTRS)

    Herring, M.; Chrien, T.; Duval, V.; Krabach, T.

    1993-01-01

    The concept of imaging spectrometry is finding broad application in scientific instrumentation for earth-based, airborne, and space applications. An imaging spectrometer is characterized by the combination of imaging with complete sampling in the spectral domain. In so doing, material identification can be accomplished and displayed in conjunction with the conventional recognizable image. An image spectrometer incorporates a wide variety of techniques, including focal plane arrays, imaging and spectrometer optics, and spectral dispersing devices. The design of a successful system involves a complex set of tradeoffs incorporating the properties and limitations of the various technologies. For applications in the infrared, additional technologies such as focal plane cooling are required, and the other technologies present more limitations and constraints.

  15. Phase diversity and polarization augmented techniques for active imaging

    NASA Astrophysics Data System (ADS)

    Johnson, Peter M.

    A firm understanding of the space environment is necessary to defend US access to space-based systems. Conventional imaging systems have been developed to gather information on space-based objects, but they are incapable of imaging objects in the earth's shadow. In order close this gap in imaging-system coverage, an active-illumination based approach must be used. To facilitate this, a multi-frame active phase diversity imaging (APDI) algorithm is derived and demonstrated for the statistics of coherent light. In addition to conventional focal-plane and diversity-plane data, a statistical description for the pupil plane intensity distribution is formed and included in the derivation. The algorithm is implemented and characterized using a Monte Carlo approach. Analysis shows that the algorithm is robust, that the effect of system configuration on optimal algorithm parameters is minimal, that the algorithm is insensitive to detection noise for SNR ≥ 7, and that it performs well for SNRs as low as 2. Furthermore, it's shown that introduction of pupil-plane data on average results in a 60% better image reconstruction from dynamically aberrated data than is obtained using only focal-plane and diversity-plane data. Both an Expectation-Maximization algorithm and a lensless-APDI approach are presented for generating imagery directly from pupil-plane polarization measurements. Shortfalls of these methods and areas worthy of further consideration are identified. The use of pupil-plane polarization state measurements in place of pupil-plane intensity measurements in the APDI algorithm is explored. A framework for including polarization measurements into the APDI algorithm is demonstrated, and an initial statistical model and results are presented. Under the developed implementation, introduction of the polarization data doesn't result in better performance. Areas that may result in better reconstructions are discussed.

  16. Illumination system characterization for hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Katrašnik, Jaka; Pernuš, Franjo; Likar, Boštjan

    2011-03-01

    Near-infrared hyperspectral imaging is becoming a popular tool in the biomedical field, especially for detection and analysis of different types of cancers, analysis of skin burns and bruises, imaging of blood vessels and for many other applications. As in all imaging systems, proper illumination is crucial to attain optimal image quality that is needed for best performance of image analysis algorithms. In hyperspectral imaging based on filters (AOTF, LCTF and filter wheel) the acquired spectral signature has to be representative in all parts of the imaged object. Therefore, the whole object must be equally well illuminated - without shadows and specular reflections. As there are no restrictions imposed on the material and geometry of the object, the desired object illumination can only be achieved with completely diffuse illumination. In order to minimize shadows and specular reflections in diffuse illumination the light illuminating the object must be spatially, angularly and spectrally uniform. We present and test two diffuse illumination system designs that try to achieve optimal uniformity of the above mentioned properties. The illumination uniformity properties were measured with an AOTF based hyperspectral imaging system utilizing a standard white diffuse reflectance target and a specially designed calibration target for estimating the spatial and angular illumination uniformity.

  17. Active Millimeter-Wave and Sub-Millimeter-Wave Imaging for Security Applications

    SciTech Connect

    Sheen, David M.; McMakin, Douglas L.; Hall, Thomas E.

    2011-09-02

    Active imaging at millimeter and sub-millimeter wavelengths has been developed for security applications including concealed weapon detection. The physical properties that affect imaging performance are discussed along with a review of the current state-of-the-art and future potential for security imaging systems.

  18. Stellar Imager (SI) Space Mission: Stellar Magnetic Activity

    NASA Technical Reports Server (NTRS)

    Carpenter, K. G.

    2006-01-01

    The Stellar Imager (SI) is a UV-Optical, Space-Based interferometer designed to enable 0.1 milli-arcsecond (mas) spectral imaging of stellar surfaces and stellar interiors (via asteroseismology) and of the Universe in general. SI is identified as a "Flagship and Landmark Discovery Mission" in the 2005 Sun Solar System Connection (SSSC) Roadmap and as a candidate for a "Pathways to Life Observatory" in the Exploration of the Universe Division (EUD) Roadmap (May, 2005). The ultra-sharp images of the Stellar Imager will revolutionize our view of many dynamic astrophysical processes: The 0.1 mas resolution of this deep-space telescope will transform point sources into extended sources, and snapshots into evolving views. SI'S science focuses on the role of magnetism in the Universe, particularly on magnetic activity on the surfaces of stars like the Sun. SI'S prime goal is to enable long-term forecasting of solar activity and the space weather that it drives in support of the Living With a Star program in the Exploration Era. SI will also revolutionize our understanding of the formation of planetary systems, of the habitability and climatology of distant planets, and of many magneto-hydrodynamically controlled processes in the Universe. In this paper we will discuss the science goals of the SI Mission and a mission architecture that could meet those goals.

  19. Optical Modeling Activities for the James Webb Space Telescope (JWST) Project. II; Determining Image Motion and Wavefront Error Over an Extended Field of View with a Segmented Optical System

    NASA Technical Reports Server (NTRS)

    Howard, Joseph M.; Ha, Kong Q.

    2004-01-01

    This is part two of a series on the optical modeling activities for JWST. Starting with the linear optical model discussed in part one, we develop centroid and wavefront error sensitivities for the special case of a segmented optical system such as JWST, where the primary mirror consists of 18 individual segments. Our approach extends standard sensitivity matrix methods used for systems consisting of monolithic optics, where the image motion is approximated by averaging ray coordinates at the image and residual wavefront error is determined with global tip/tilt removed. We develop an exact formulation using the linear optical model, and extend it to cover multiple field points for performance prediction at each instrument aboard JWST. This optical model is then driven by thermal and dynamic structural perturbations in an integrated modeling environment. Results are presented.

  20. Cardiac anisotropy: is it negligible regarding noninvasive activation time imaging?

    PubMed

    Modre, Robert; Seger, Michael; Fischer, Gerald; Hintermüller, Christoph; Hayn, Dieter; Pfeifer, Bernhard; Hanser, Friedrich; Schreier, Günter; Tilg, Bernhard

    2006-04-01

    The aim of this study was to quantify the effect of cardiac anisotropy in the activation-based inverse problem of electrocardiography. Differences of the patterns of simulated body surface potential maps for isotropic and anisotropic conditions were investigated with regard to activation time (AT) imaging of ventricular depolarization. AT maps were estimated by solving the nonlinear inverse ill-posed problem employing spatio-temporal regularization. Four different reference AT maps (sinus rhythm, right-ventricular and septal pacing, accessory pathway) were calculated with a bidomain theory based anisotropic finite-element heart model in combination with a cellular automaton. In this heart model a realistic fiber architecture and conduction system was implemented. Although the anisotropy has some effects on forward solutions, effects on inverse solutions are small indicating that cardiac anisotropy might be negligible for some clinical applications (e.g., imaging of focal events) of our AT imaging approach. The main characteristic events of the AT maps were estimated despite neglected electrical anisotropy in the inverse formulation. The worst correlation coefficient of the estimated AT maps was 0.810 in case of sinus rhythm. However, all characteristic events of the activation pattern were found. The results of this study confirm our clinical validation studies of noninvasive AT imaging in which cardiac anisotropy was neglected.

  1. Advanced laser systems for photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Klosner, Marc; Sampathkumar, Ashwin; Chan, Gary; Wu, Chunbai; Gross, Daniel; Heller, Donald F.

    2015-03-01

    We describe the ongoing development of laser systems for advanced photoacoustic imaging (PAI). We discuss the characteristics of these laser systems and their particular benefits for soft tissue imaging and next-generation breast cancer diagnostics. We provide an overview of laser performance and compare this with other laser systems that have been used for early-stage development of PAI. These advanced systems feature higher pulse energy output at clinically relevant repetition rates, as well as a novel wavelength-cycling output pulse format. Wavelength cycling provides pulse sequences for which the output repeatedly alternates between two wavelengths that provide differential imaging. This capability improves co-registration of captured differential images. We present imaging results of phantoms obtained with a commercial ultrasound detector system and a wavelength-cycling laser source providing ~500 mJ/pulse at 755 and 797 nm, operating at 25 Hz. The results include photoacoustic images and corresponding pulse-echo data from a tissue mimicking phantom containing inclusions, simulating tumors in the breast. We discuss the application of these systems to the contrast-enhanced detection of various tissue types and tumors.

  2. Onboard Image Processing System for Hyperspectral Sensor.

    PubMed

    Hihara, Hiroki; Moritani, Kotaro; Inoue, Masao; Hoshi, Yoshihiro; Iwasaki, Akira; Takada, Jun; Inada, Hitomi; Suzuki, Makoto; Seki, Taeko; Ichikawa, Satoshi; Tanii, Jun

    2015-09-25

    Onboard image processing systems for a hyperspectral sensor have been developed in order to maximize image data transmission efficiency for large volume and high speed data downlink capacity. Since more than 100 channels are required for hyperspectral sensors on Earth observation satellites, fast and small-footprint lossless image compression capability is essential for reducing the size and weight of a sensor system. A fast lossless image compression algorithm has been developed, and is implemented in the onboard correction circuitry of sensitivity and linearity of Complementary Metal Oxide Semiconductor (CMOS) sensors in order to maximize the compression ratio. The employed image compression method is based on Fast, Efficient, Lossless Image compression System (FELICS), which is a hierarchical predictive coding method with resolution scaling. To improve FELICS's performance of image decorrelation and entropy coding, we apply a two-dimensional interpolation prediction and adaptive Golomb-Rice coding. It supports progressive decompression using resolution scaling while still maintaining superior performance measured as speed and complexity. Coding efficiency and compression speed enlarge the effective capacity of signal transmission channels, which lead to reducing onboard hardware by multiplexing sensor signals into a reduced number of compression circuits. The circuitry is embedded into the data formatter of the sensor system without adding size, weight, power consumption, and fabrication cost.

  3. Onboard Image Processing System for Hyperspectral Sensor

    PubMed Central

    Hihara, Hiroki; Moritani, Kotaro; Inoue, Masao; Hoshi, Yoshihiro; Iwasaki, Akira; Takada, Jun; Inada, Hitomi; Suzuki, Makoto; Seki, Taeko; Ichikawa, Satoshi; Tanii, Jun

    2015-01-01

    Onboard image processing systems for a hyperspectral sensor have been developed in order to maximize image data transmission efficiency for large volume and high speed data downlink capacity. Since more than 100 channels are required for hyperspectral sensors on Earth observation satellites, fast and small-footprint lossless image compression capability is essential for reducing the size and weight of a sensor system. A fast lossless image compression algorithm has been developed, and is implemented in the onboard correction circuitry of sensitivity and linearity of Complementary Metal Oxide Semiconductor (CMOS) sensors in order to maximize the compression ratio. The employed image compression method is based on Fast, Efficient, Lossless Image compression System (FELICS), which is a hierarchical predictive coding method with resolution scaling. To improve FELICS’s performance of image decorrelation and entropy coding, we apply a two-dimensional interpolation prediction and adaptive Golomb-Rice coding. It supports progressive decompression using resolution scaling while still maintaining superior performance measured as speed and complexity. Coding efficiency and compression speed enlarge the effective capacity of signal transmission channels, which lead to reducing onboard hardware by multiplexing sensor signals into a reduced number of compression circuits. The circuitry is embedded into the data formatter of the sensor system without adding size, weight, power consumption, and fabrication cost. PMID:26404281

  4. Onboard Image Processing System for Hyperspectral Sensor.

    PubMed

    Hihara, Hiroki; Moritani, Kotaro; Inoue, Masao; Hoshi, Yoshihiro; Iwasaki, Akira; Takada, Jun; Inada, Hitomi; Suzuki, Makoto; Seki, Taeko; Ichikawa, Satoshi; Tanii, Jun

    2015-01-01

    Onboard image processing systems for a hyperspectral sensor have been developed in order to maximize image data transmission efficiency for large volume and high speed data downlink capacity. Since more than 100 channels are required for hyperspectral sensors on Earth observation satellites, fast and small-footprint lossless image compression capability is essential for reducing the size and weight of a sensor system. A fast lossless image compression algorithm has been developed, and is implemented in the onboard correction circuitry of sensitivity and linearity of Complementary Metal Oxide Semiconductor (CMOS) sensors in order to maximize the compression ratio. The employed image compression method is based on Fast, Efficient, Lossless Image compression System (FELICS), which is a hierarchical predictive coding method with resolution scaling. To improve FELICS's performance of image decorrelation and entropy coding, we apply a two-dimensional interpolation prediction and adaptive Golomb-Rice coding. It supports progressive decompression using resolution scaling while still maintaining superior performance measured as speed and complexity. Coding efficiency and compression speed enlarge the effective capacity of signal transmission channels, which lead to reducing onboard hardware by multiplexing sensor signals into a reduced number of compression circuits. The circuitry is embedded into the data formatter of the sensor system without adding size, weight, power consumption, and fabrication cost. PMID:26404281

  5. Design and simulation of imaging algorithm for Fresnel telescopy imaging system

    NASA Astrophysics Data System (ADS)

    Lv, Xiao-yu; Liu, Li-ren; Yan, Ai-min; Sun, Jian-feng; Dai, En-wen; Li, Bing

    2011-06-01

    Fresnel telescopy (short for Fresnel telescopy full-aperture synthesized imaging ladar) is a new high resolution active laser imaging technique. This technique is a variant of Fourier telescopy and optical scanning holography, which uses Fresnel zone plates to scan target. Compare with synthetic aperture imaging ladar(SAIL), Fresnel telescopy avoids problem of time synchronization and space synchronization, which decreasing technical difficulty. In one-dimensional (1D) scanning operational mode for moving target, after time-to-space transformation, spatial distribution of sampling data is non-uniform because of the relative motion between target and scanning beam. However, as we use fast Fourier transform (FFT) in the following imaging algorithm of matched filtering, distribution of data should be regular and uniform. We use resampling interpolation to transform the data into two-dimensional (2D) uniform distribution, and accuracy of resampling interpolation process mainly affects the reconstruction results. Imaging algorithms with different resampling interpolation algorithms have been analysis and computer simulation are also given. We get good reconstruction results of the target, which proves that the designed imaging algorithm for Fresnel telescopy imaging system is effective. This work is found to have substantial practical value and offers significant benefit for high resolution imaging system of Fresnel telescopy laser imaging ladar.

  6. An Open System for Intravascular Ultrasound Imaging

    PubMed Central

    Qiu, Weibao; Chen, Yan; Li, Xiang; Yu, Yanyan; Cheng, Wang Fai; Tsang, Fu Keung; Zhou, Qifa; Shung, K. Kirk; Dai, Jiyan; Sun, Lei

    2013-01-01

    Visualization of the blood vessels can provide valuable morphological information for diagnosis and therapy strategies for cardiovascular disease. Intravascular ultrasound (IVUS) is able to delineate internal structures of vessel wall with fine spatial resolution. However, the developed IVUS is insufficient to identify the fibrous cap thickness and tissue composition of atherosclerotic lesions. Novel imaging strategies have been proposed, such as increasing the center frequency of ultrasound or using a modulated excitation technique to improve the accuracy of diagnosis. Dual-mode tomography combining IVUS with optical tomography has also been developed to determine tissue morphology and characteristics. The implementation of these new imaging methods requires an open system that allows users to customize the system for various studies. This paper presents the development of an IVUS system that has open structures to support various imaging strategies. The system design is based on electronic components and printed circuit board, and provides reconfigurable hardware implementation, programmable image processing algorithms, flexible imaging control, and raw RF data acquisition. In addition, the proposed IVUS system utilized a miniaturized ultrasound transducer constructed using PMN-PT single crystal for better piezoelectric constant and electromechanical coupling coefficient than traditional lead zirconate titanate (PZT) ceramics. Testing results showed that the IVUS system could offer a minimum detectable signal of 25 μV, allowing a 51 dB dynamic range at 47 dB gain, with a frequency range from 20 to 80 MHz. Finally, phantom imaging, in vitro IVUS vessel imaging, and multimodality imaging with photoacoustics were conducted to demonstrate the performance of the open system. PMID:23143570

  7. Image-based panoramic virtual reality system

    NASA Astrophysics Data System (ADS)

    Ritchey, Kurtis J.

    1992-06-01

    An extensive family of advanced virtual reality-telepresence systems and components have been developed. The purpose of these systems and components is to facilitate recording, processing, display, and interaction with audio and video signal(s) representing a scene or subject of three-dimensions (3-D). An overview of the systems currently available for license includes: a color video camera with real-time simultaneous spherical FOV coverage; a similar camera for recording various sides of a 3-D subject; an image based system for real-time processing and distribution of said camera based images onto 3-D wireframes; resultant camcorders are generally referred to as virtual reality/telepresence 'VRT camcorders'TM; a 'VIDEOROOM'TM large theater display system in which the floor, walls, and ceiling form a continuous display about the viewer for display of said images; 'INaVISION'TM a HMD system for viewing the same said images; and interactive control devices for manipulating said 3-D image and audio signal(s). Applications, to include visual and auditory simulation, host vehicle control, remote vehicle control, video teleconferencing, and so on, are feasible applications for the above technology. Rough costs of systems and components, photographs of a prototype system, and component illustrations are provided. Future directions of R&D are presented (i.e., Project HEAVEN: Humankind Eternal-Life Artificial-Intelligence Virtual Environment Network).

  8. Image Chain Analysis For Digital Image Rectification System

    NASA Astrophysics Data System (ADS)

    Arguello, Roger J.

    1981-07-01

    An image chain analysis, utilizing a comprehensive computer program, has been gen-erated for the key elements of a digital image rectification system. System block dia-grams and analyses for three system configurations employing film scanner input have been formulated with a parametric specification of pertinent element modulation transfer functions and input film scene spectra. The major elements of the system for this analy-sis include a high-resolution, high-speed charge-coupled device film scanner, three candidate digital resampling option algorithms (i.e., nearest neighbor, bilinear inter-polation and cubic convolution methods), and two candidate printer reconstructor implemen-tations (solid-state light-emitting diode printer and laser beam recorder). Suitable metrics for the digital rectification system, incorporating the effects of interpolation and resolution error, were established, and the image chain analysis program was used to perform a quantitative comparison of the three resampling options with the two candi-date printer reconstructor implementations. The nearest neighbor digital resampling function is found to be a good compromise choice when cascaded with either a light-emit-ting diode printer or laser beam recorder. The resulting composite intensity point spread functions, including resampling, and both types of reconstruction are bilinear and quadratic, respectively.

  9. Hologlyphics: volumetric image synthesis performance system

    NASA Astrophysics Data System (ADS)

    Funk, Walter

    2008-02-01

    This paper describes a novel volumetric image synthesis system and artistic technique, which generate moving volumetric images in real-time, integrated with music. The system, called the Hologlyphic Funkalizer, is performance based, wherein the images and sound are controlled by a live performer, for the purposes of entertaining a live audience and creating a performance art form unique to volumetric and autostereoscopic images. While currently configured for a specific parallax barrier display, the Hologlyphic Funkalizer's architecture is completely adaptable to various volumetric and autostereoscopic display technologies. Sound is distributed through a multi-channel audio system; currently a quadraphonic speaker setup is implemented. The system controls volumetric image synthesis, production of music and spatial sound via acoustic analysis and human gestural control, using a dedicated control panel, motion sensors, and multiple musical keyboards. Music can be produced by external acoustic instruments, pre-recorded sounds or custom audio synthesis integrated with the volumetric image synthesis. Aspects of the sound can control the evolution of images and visa versa. Sounds can be associated and interact with images, for example voice synthesis can be combined with an animated volumetric mouth, where nuances of generated speech modulate the mouth's expressiveness. Different images can be sent to up to 4 separate displays. The system applies many novel volumetric special effects, and extends several film and video special effects into the volumetric realm. Extensive and various content has been developed and shown to live audiences by a live performer. Real world applications will be explored, with feedback on the human factors.

  10. Reflective optical imaging system with balanced distortion

    DOEpatents

    Chapman, Henry N.; Hudyma, Russell M.; Shafer, David R.; Sweeney, Donald W.

    1999-01-01

    An optical system compatible with short wavelength (extreme ultraviolet) An optical system compatible with short wavelength (extreme ultraviolet) radiation comprising four reflective elements for projecting a mask image onto a substrate. The four optical elements comprise, in order from object to image, convex, concave, convex and concave mirrors. The optical system is particularly suited for step and scan lithography methods. The invention enables the use of larger slit dimensions associated with ring field scanning optics, improves wafer throughput and allows higher semiconductor device density. The inventive optical system is characterized by reduced dynamic distortion because the static distortion is balanced across the slit width.

  11. EOS image data processing system definition study

    NASA Technical Reports Server (NTRS)

    Gilbert, J.; Honikman, T.; Mcmahon, E.; Miller, E.; Pietrzak, L.; Yorsz, W.

    1973-01-01

    The Image Processing System (IPS) requirements and configuration are defined for NASA-sponsored advanced technology Earth Observatory System (EOS). The scope included investigation and definition of IPS operational, functional, and product requirements considering overall system constraints and interfaces (sensor, etc.) The scope also included investigation of the technical feasibility and definition of a point design reflecting system requirements. The design phase required a survey of present and projected technology related to general and special-purpose processors, high-density digital tape recorders, and image recorders.

  12. Intelligent imaging systems for automotive applications

    NASA Astrophysics Data System (ADS)

    Thompson, Chris; Huang, Yingping; Fu, Shan

    2004-03-01

    In common with many other application areas, visual signals are becoming an increasingly important information source for many automotive applications. For several years CCD cameras have been used as research tools for a range of automotive applications. Infrared cameras, RADAR and LIDAR are other types of imaging sensors that have also been widely investigated for use in cars. This paper will describe work in this field performed in C2VIP over the last decade - starting with Night Vision Systems and looking at various other Advanced Driver Assistance Systems. Emerging from this experience, we make the following observations which are crucial for "intelligent" imaging systems: 1. Careful arrangement of sensor array. 2. Dynamic-Self-Calibration. 3. Networking and processing. 4. Fusion with other imaging sensors, both at the image level and the feature level, provides much more flexibility and reliability in complex situations. We will discuss how these problems can be addressed and what are the outstanding issues.

  13. Quantitative evaluation of digital dental radiograph imaging systems.

    PubMed

    Hildebolt, C F; Vannier, M W; Pilgram, T K; Shrout, M K

    1990-11-01

    Two digital imaging systems, a video camera and analog-to-digital converter, and a charge-coupled device linear photodiode array slide scanner, were tested for their suitability in quantitative studies of periodontal disease. The information content in the original films was estimated, and digital systems were assessed according to these requirements. Radiometric and geometric performance criteria for the digital systems were estimated from measurements and observations. The scanner-based image acquisition (digitization) system had no detectable noise and had a modulation transfer function curve superior to that of the video-based system. The scanner-based system was equivalent to the video-based system in recording radiographic film densities and had more geometric distortion than the video-based system. The comparison demonstrated the superiority of the charge-coupled device linear array system for the quantification of periodontal disease extent and activity. PMID:2234888

  14. Development of a triple modality small animal planar imaging system

    SciTech Connect

    A. G. Weisenberger, Z. Lee, S. Majewski, B. Kross, V. Popov, B. Welch, R. Wojcik, C. Zorn

    2006-02-01

    Recently small animal research utilizing nuclear medicine based imaging has been combined with structural anatomical imaging from x-ray radiography providing a powerful tool for animal researchers. The addition of a third modality is the goal of our instrumentation development. Thomas Jefferson National Accelerator Facility and Case Western Reserve University have been collaborating on the development of a planar imaging system which in addition to radiopharmaceutical based functional imaging and x-ray radiography structural imaging also allows for the in vivo bioluminescence imaging thus providing another functional imaging modality. For the gamma camera we use is a Hamamatsu position sensitive photomultiplier tube coupled to a pixellated NaI(TI) scintillator array with individual crystal elements 1 mm × 1 mm × 5 mm in size and a 0.25 mm septum between each element. The gamma camera has a 10 cm diameter active area and can be used for 125I, 99mT and 111In radionuclide imaging. To acquire anatomical information we are using a Rad-Icon Shad-o-Box X-ray detector that provides a field of view of 5 cm × 10 cm. The x-ray source is a Source-Ray compact x-ray generator. We are using a Princeton Instruments cooled CCD based detector for the imaging of the bio-distribution of bioluminescence. All three imaging instruments will be integrated into a single light tight / x-ray tight enclosure.

  15. A novel multiwavelength fluorescence image-guided surgery imaging system

    NASA Astrophysics Data System (ADS)

    Volpi, D.; Tullis, I. D. C.; Laios, A.; Pathiraja, P. N. J.; Haldar, K.; Ahmed, A. A.; Vojnovic, B.

    2014-02-01

    We describe the development and performance analysis of two clinical near-infrared fluorescence image-guided surgery (FIGS) devices that aim to overcome some of the limitations of current FIGS systems. The devices operate in a widefield-imaging mode and can work (1) in conjunction with a laparoscope, during minimally invasive surgery, and (2) as a hand-held, open surgery imaging system. In both cases, narrow-band excitation light, delivered at multiple wavelengths, is efficiently combined with white reflectance light. Light is delivered to ~100 cm2 surgical field at 1-2 mW/cm2 for white light and 3-7 mW/cm2 (depending on wavelength) of red - near infrared excitation, at a typical working distance of 350 mm for the hand-held device and 100 mm for the laparoscope. A single, sensitive, miniaturized color camera collects both fluorescence and white reflectance light. The use of a single imager eliminates image alignment and software overlay complexity. A novel filtering and illumination arrangement allows simultaneous detection of white reflectance and fluorescence emission from multiple dyes in real-time. We will present both fluorescence detection sensitivity modeling and practical performance data. We have demonstrated the efficiency and the advantages of the devices both pre-clinically and during live surgery on humans. Both the hand-held and the laparoscopic systems have proved to be reliable and beneficial in an ongoing clinical trial involving sentinel lymph node detection in gynecological cancers. We will show preliminary results using two clinically approved dyes, Methylene blue and indocyanine green. We anticipate that this technology can be integrated and routinely used in a larger variety of surgical procedures.

  16. An image retrieval system based on fractal dimension.

    PubMed

    Yao, Min; Yi, Wen-Sheng; Shen, Bin; Dai, Hong-Hua

    2003-01-01

    This paper presents a new kind of image retrieval system which obtains the feature vectors of images by estimating their fractal dimension; and at the same time establishes a tree-structure image database. After preprocessing and feature extracting, a given image is matched with the standard images in the image database using a hierarchical method of image indexing.

  17. Image-based systems biology of infection.

    PubMed

    Medyukhina, Anna; Timme, Sandra; Mokhtari, Zeinab; Figge, Marc Thilo

    2015-06-01

    The successful treatment of infectious diseases requires interdisciplinary studies of all aspects of infection processes. The overarching combination of experimental research and theoretical analysis in a systems biology approach can unravel mechanisms of complex interactions between pathogens and the human immune system. Taking into account spatial information is especially important in the context of infection, since the migratory behavior and spatial interactions of cells are often decisive for the outcome of the immune response. Spatial information is provided by image and video data that are acquired in microscopy experiments and that are at the heart of an image-based systems biology approach. This review demonstrates how image-based systems biology improves our understanding of infection processes. We discuss the three main steps of this approach--imaging, quantitative characterization, and modeling--and consider the application of these steps in the context of studying infection processes. After summarizing the most relevant microscopy and image analysis approaches, we discuss ways to quantify infection processes, and address a number of modeling techniques that exploit image-derived data to simulate host-pathogen interactions in silico.

  18. Anonymization server system for DICOM images

    NASA Astrophysics Data System (ADS)

    Suzuki, H.; Amano, M.; Kubo, M.; Kawata, Y.; Niki, N.; Nishitani, H.

    2007-03-01

    We have developed an anonymization system for DICOM images. It requires consent from the patient to use the DICOM images for research or education. However, providing the DICOM image to the other facilities is not safe because it contains a lot of personal data. Our system is a server that provides anonymization service of DICOM images for users in the facility. The distinctive features of the system are, input interface, flexible anonymization policy, and automatic body part identification. In the first feature, we can use the anonymization service on the existing DICOM workstations. In the second feature, we can select a best policy fitting for the Protection of personal data that is ruled by each medical facility. In the third feature, we can identify the body parts that are included in the input image set, even if the set lacks the body part tag in DICOM header. We installed the system for the first time to a hospital in December 2005. Currently, the system is working in other four facilities. In this paper we describe the system and how it works.

  19. Overcoming Dynamic Disturbances in Imaging Systems

    NASA Technical Reports Server (NTRS)

    Young, Eric W.; Dente, Gregory C.; Lyon, Richard G.; Chesters, Dennis; Gong, Qian

    2000-01-01

    We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optormechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel

  20. Overcoming Dynamic Disturbances in Imaging Systems

    NASA Technical Reports Server (NTRS)

    Young, Eric W.; Dente, Gregory C.; Lyon, Richard G.; Chesters, Dennis; Gong, Qian

    2000-01-01

    We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optomechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel

  1. A scanning system for intelligent imaging: I-ImaS

    NASA Astrophysics Data System (ADS)

    Longo, R.; Asimidis, A.; Cavouras, D.; Esbrand, C.; Fant, A.; Gasiorek, P.; Georgiou, H.; Hall, G.; Jones, J.; Leaver, J.; Li, G.; Griffiths, J.; Machin, D.; Manthos, N.; Metaxas, M.; Noy, M.; Østby, J. M.; Psomadellis, F.; Rokvic, T.; Royle, G.; Schulerud, H.; Speller, R.; van der Stelt, PF.; Theodoridis, S.; Triantis, F.; Turchetta, R.; Venanzi, C.

    2007-03-01

    I-ImaS (Intelligent Imaging Sensors) is a European project aiming to produce adaptive x-ray imaging systems using Monolithic Active Pixel Sensors (MAPS) to create optimal diagnostic images. Initial systems concentrate on mammography and cephalography. The on-chip intelligence available to MAPS technology will allow real-time analysis of data during image acquisition, giving the capability to build a truly adaptive imaging system with the potential to create images with maximum diagnostic information within given dose constraints. In our system, the exposure in each image region is optimized and the beam intensity is a function not only of tissue thickness and attenuation, but also of local physical and statistical parameters found in the image itself. Using a linear array of detectors with on-chip intelligence, the system will perform an on-line analysis of the image during the scan and then will optimize the X-ray intensity in order to obtain the maximum diagnostic information from the region of interest while minimizing exposure of less important, or simply less dense, regions. This paper summarizes the testing of the sensors and their electronics carried out using synchrotron radiation, x-ray sources and optical measurements. The sensors are tiled to form a 1.5D linear array. These have been characterised and appropriate correction techniques formulated to take into account misalignments between individual sensors. Full testing of the mammography and cephalography I-ImaS prototypes is now underway and the system intelligence is constantly being upgraded through iterative testing in order to obtain the optimal algorithms and settings.

  2. CMOS Active Pixel Sensor (APS) Imager for Scientific Applications

    NASA Astrophysics Data System (ADS)

    Ay, Suat U.; Lesser, Michael P.; Fossum, Eric R.

    2002-12-01

    A 512×512 CMOS Active Pixel Sensor (APS) imager has been designed, fabricate, and tested for frontside illumination suitable for use in astronomy specifically in telescope guider systems as a replacement of CCD chips. The imager features a high-speed differential analog readout, 15 μm pixel pitch, 75 % fill factor (FF), 62 dB dynamic range, 315Ke- pixel capacity, less than 0.25% fixed pattern noise (FPN), 45 dB signal to noise ratio (SNR) and frame rate of up to 40 FPS. Design was implemented in a standard 0.5 μm CMOS process technology consuming less than 200mWatts on a single 5 Volt power supply. CMOS Active Pixel Sensor (APS) imager was developed with pixel structure suitable for both frontside and backside illumination holding large number of electron in relatively small pixel pitch of 15 μm. High-speed readout and signal processing circuits were designed to achieve low fixed pattern noise (FPN) and non-uniformity to provide CCD-like analog outputs. Target spectrum range of operation for the imager is in near ultraviolet (300-400 nm) with high quantum efficiency. This device is going to be used as a test vehicle to develop backside-thinning process.

  3. Obstacle penetrating dynamic radar imaging system

    DOEpatents

    Romero, Carlos E.; Zumstein, James E.; Chang, John T.; Leach, Jr.. Richard R.

    2006-12-12

    An obstacle penetrating dynamic radar imaging system for the detection, tracking, and imaging of an individual, animal, or object comprising a multiplicity of low power ultra wideband radar units that produce a set of return radar signals from the individual, animal, or object, and a processing system for said set of return radar signals for detection, tracking, and imaging of the individual, animal, or object. The system provides a radar video system for detecting and tracking an individual, animal, or object by producing a set of return radar signals from the individual, animal, or object with a multiplicity of low power ultra wideband radar units, and processing said set of return radar signals for detecting and tracking of the individual, animal, or object.

  4. Numerical simulation of imaging laser radar system

    NASA Astrophysics Data System (ADS)

    Han, Shaokun; Lu, Bo; Jiang, Ming; Liu, Xunliang

    2008-03-01

    Rational and effective design of imaging laser radar systems is the key of imaging laser radar system research. Design must fully consider the interrelationship between various parameters. According to the parameters, choose suitable laser, detector and other components. To use of mathematical modeling and computer simulation is an effective imaging laser radar system design methods. This paper based on the distance equation, using the detection statistical methods, from the laser radar range coverage, detection probability, false-alarm rate, SNR to build the laser radar system mathematical models. In the process of setting up the mathematical models to fully consider the laser, atmosphere, detector and other factors on the performance that is to make the models be able to respond accurately the real situation. Based on this using C# and Matlab designed a simulation software.

  5. Multimodal imaging system for dental caries detection

    NASA Astrophysics Data System (ADS)

    Liang, Rongguang; Wong, Victor; Marcus, Michael; Burns, Peter; McLaughlin, Paul

    2007-02-01

    Dental caries is a disease in which minerals of the tooth are dissolved by surrounding bacterial plaques. A caries process present for some time may result in a caries lesion. However, if it is detected early enough, the dentist and dental professionals can implement measures to reverse and control caries. Several optical, nonionized methods have been investigated and used to detect dental caries in early stages. However, there is not a method that can singly detect the caries process with both high sensitivity and high specificity. In this paper, we present a multimodal imaging system that combines visible reflectance, fluorescence, and Optical Coherence Tomography (OCT) imaging. This imaging system is designed to obtain one or more two-dimensional images of the tooth (reflectance and fluorescence images) and a three-dimensional OCT image providing depth and size information of the caries. The combination of two- and three-dimensional images of the tooth has the potential for highly sensitive and specific detection of dental caries.

  6. Digital image-rectification system

    NASA Technical Reports Server (NTRS)

    Van Wie, P. H.; Stein, M.; Puccinelli, E.; Fields, B.

    1977-01-01

    System removes spatial distortions from data and brings data into conformance with Universal Transverse Mercator map projection, produces digital output products suitable for further machine processing and analysis, and fills need for geometrically corrected Landsat multispectral scanner digital data in several remote sensing application areas.

  7. Distributed-data imaging system

    SciTech Connect

    Tolmie, D.E.; Dornhoff, A.G.; DuBois, A.J.; Hodson, S.W.; Maestas, F.A.; Winkler, K.H.

    1996-05-01

    A group of eight Digital Equipment Corporation Alpha workstations is interconnected with ATM to form a cluster with supercomputer power. For output, each workstation drives a single tile on an 8-tile high- resolution frame buffer. A special purpose adapter is used to convert the workstation`s ATM format to the frame buffer`s HIPPI format. This paper discusses the rationale behind the workstation farm, and then describes the visualization output path in detail. To provide the system quickly, special emphasis was placed on making the design as simple as possible and using standard software protocols to drive and synchronize the display. The design choices are examined, and the resultant system is described.. Previously, a display could connect to a single computer; or a group of computers could drive a fragmented display, e.g., a video wall. Our system is unique in that it provides a high-quality desktop visualization display driven collectively by a group of workstations. A short video will be shown during the presentation to demonstrate the system capabilities.

  8. Display system for imaging scientific telemetric information

    NASA Technical Reports Server (NTRS)

    Zabiyakin, G. I.; Rykovanov, S. N.

    1979-01-01

    A system for imaging scientific telemetric information, based on the M-6000 minicomputer and the SIGD graphic display, is described. Two dimensional graphic display of telemetric information and interaction with the computer, in analysis and processing of telemetric parameters displayed on the screen is provided. The running parameter information output method is presented. User capabilities in the analysis and processing of telemetric information imaged on the display screen and the user language are discussed and illustrated.

  9. THERMAL IMAGING OF ACTIVE MAGNETIC REGERNERATOR MCE MATERIALS DURING OPERATION

    SciTech Connect

    Shassere, Benjamin; West, David L; Abdelaziz, Omar; Evans III, Boyd Mccutchen

    2012-01-01

    An active magnetic regenerator (AMR) prototype was constructed that incorporates a Gd sheet into the regenerator wall to enable visualization of the system s thermal transients. In this experiment, the thermal conditions inside the AMR are observed under a variety of operating conditions. An infrared (IR) camera is employed to visualize the thermal transients within the AMR. The IR camera is used to visually and quantitatively evaluate the temperature difference and thus giving means to calculate the performance of the system under the various operating conditions. Thermal imaging results are presented for two differing experimental test runs. Real time imaging of the thermal state of the AMR has been conducted while operating the system over a range of conditions. A 1 Tesla twin-coil electromagnet (situated on a C frame base) is used for this experiment such that all components are stationary during testing. A modular, linear reciprocating system has been realized in which the effects of regenerator porosity and utilization factor can be investigated. To evaluate the performance variation in porosity and utilization factor the AMR housing was constructed such that the plate spacing of the Gd sheets may be varied. Each Gd sheet has dimensions of 38 mm wide and 66 mm long with a thickness of 1 mm and the regenerator can hold a maximum of 29 plates with a spacing of 0.25 mm. Quantitative and thermal imaging results are presented for several regenerator configurations.

  10. Biomedical Imaging in Implantable Drug Delivery Systems

    PubMed Central

    Zhou, Haoyan; Hernandez, Christopher; Goss, Monika; Gawlik, Anna; Exner, Agata A.

    2015-01-01

    Implantable drug delivery systems (DDS) provide a platform for sustained release of therapeutic agents over a period of weeks to months and sometimes years. Such strategies are typically used clinically to increase patient compliance by replacing frequent administration of drugs such as contraceptives and hormones to maintain plasma concentration within the therapeutic window. Implantable or injectable systems have also been investigated as a means of local drug administration which favors high drug concentration at a site of interest, such as a tumor, while reducing systemic drug exposure to minimize unwanted side effects. Significant advances in the field of local DDS have led to increasingly sophisticated technology with new challenges including quantification of local and systemic pharmacokinetics and implant-body interactions. Because many of these sought-after parameters are highly dependent on the tissue properties at the implantation site, and rarely represented adequately with in vitro models, new nondestructive techniques that can be used to study implants in situ are highly desirable. Versatile imaging tools can meet this need and provide quantitative data on morphological and functional aspects of implantable systems. The focus of this review article is an overview of current biomedical imaging techniques, including magnetic resonance imaging (MRI), ultrasound imaging, optical imaging, X-ray and computed tomography (CT), and their application in evaluation of implantable DDS. PMID:25418857

  11. Image change detection systems, methods, and articles of manufacture

    DOEpatents

    Jones, James L.; Lassahn, Gordon D.; Lancaster, Gregory D.

    2010-01-05

    Aspects of the invention relate to image change detection systems, methods, and articles of manufacture. According to one aspect, a method of identifying differences between a plurality of images is described. The method includes loading a source image and a target image into memory of a computer, constructing source and target edge images from the source and target images to enable processing of multiband images, displaying the source and target images on a display device of the computer, aligning the source and target edge images, switching displaying of the source image and the target image on the display device, to enable identification of differences between the source image and the target image.

  12. Dual-modality imaging system combined fast photoacoustic imaging and ultrasound imaging

    NASA Astrophysics Data System (ADS)

    Xiang, Liangzhong; Yuan, Yi

    2009-08-01

    In this paper, we have developed a fast dual-modality imaging system for reconstruction photoacoustic and ultrasound imaging based on a novel digital phased array. The scanning mode and image reconstruction algorithms were modified from our previous work to improve the image quality. A 128-element linear transducer array is connected to a multichannel signal acquisition and digital beam-formation system providing techniques of dynamic receiving focus and dynamic receiving apodization to process the signal. We use the linear transducer array with combined scanning mode to detect signals at multiple locations on a circle around the sample. It makes our dual-modality imaging own the ability of imaging complicated structures of objects. An improved limited-field filtered back projection algorithm with directivity factors was applied in photoacoustic imaging to further improve the lateral resolution. Phase-controlled imaging algorithm was applied to reconstruct acoustical impedance difference in the pure ultrasound imaging. The experiments on phantoms and in vivo early breast cancer detection in a mouse model were performed. The images are clearly, accurately provided.

  13. The Assessment of Neurological Systems with Functional Imaging

    ERIC Educational Resources Information Center

    Eidelberg, David

    2007-01-01

    In recent years a number of multivariate approaches have been introduced to map neural systems in health and disease. In this review, we focus on spatial covariance methods applied to functional imaging data to identify patterns of regional activity associated with behavior. In the rest state, this form of network analysis can be used to detect…

  14. apART: system for the acquisition, processing, archiving, and retrieval of digital images in an open, distributed imaging environment

    NASA Astrophysics Data System (ADS)

    Schneider, Uwe; Strack, Ruediger

    1992-04-01

    apART reflects the structure of an open, distributed environment. According to the general trend in the area of imaging, network-capable, general purpose workstations with capabilities of open system image communication and image input are used. Several heterogeneous components like CCD cameras, slide scanners, and image archives can be accessed. The system is driven by an object-oriented user interface where devices (image sources and destinations), operators (derived from a commercial image processing library), and images (of different data types) are managed and presented uniformly to the user. Browsing mechanisms are used to traverse devices, operators, and images. An audit trail mechanism is offered to record interactive operations on low-resolution image derivatives. These operations are processed off-line on the original image. Thus, the processing of extremely high-resolution raster images is possible, and the performance of resolution dependent operations is enhanced significantly during interaction. An object-oriented database system (APRIL), which can be browsed, is integrated into the system. Attribute retrieval is supported by the user interface. Other essential features of the system include: implementation on top of the X Window System (X11R4) and the OSF/Motif widget set; a SUN4 general purpose workstation, inclusive ethernet, magneto optical disc, etc., as the hardware platform for the user interface; complete graphical-interactive parametrization of all operators; support of different image interchange formats (GIF, TIFF, IIF, etc.); consideration of current IPI standard activities within ISO/IEC for further refinement and extensions.

  15. Molecular imaging of macrophage enzyme activity in cardiac inflammation

    PubMed Central

    Ali, Muhammad; Pulli, Benjamin; Chen, John W.

    2014-01-01

    Molecular imaging is highly advantageous as various insidious inflammatory events can be imaged in a serial and quantitative fashion. Combined with the conventional imaging modalities like computed tomography (CT), magnetic resonance (MR) and nuclear imaging, it helps us resolve the extent of ongoing pathology, quantify inflammation and predict outcome. Macrophages are increasingly gaining importance as an imaging biomarker in inflammatory cardiovascular diseases. Macrophages, recruited to the site of injury, internalize necrotic or foreign material. Along with phagocytosis, activated macrophages release proteolytic enzymes like matrix metalloproteinases (MMPs) and cathepsins into the extracellular environment. Pro-inflammatory monocytes and macrophages also induce tissue oxidative damage through the inflammatory enzyme myeloperoxidase (MPO). In this review we will highlight recent advances in molecular macrophage imaging. Particular stress will be given to macrophage functional and enzymatic activity imaging which targets phagocytosis, proteolysis and myeloperoxidase activity imaging. PMID:24729833

  16. Multimodal polarization system for imaging skin cancer

    NASA Astrophysics Data System (ADS)

    Salomatina-Motts, E.; Neel, V. A.; Yaroslavskaya, A. N.

    2009-12-01

    An optical system is created that is capable of detecting tumor formations in vivo in real time by means of the spectrally resolved polarization imaging of light elastically scattered by tissue and imaging of fluorescence polarization of exogenous fluorophores. The performance characteristics of the system, such as the resolution, field of view, and power density and stability of the radiation, as well as the calibration G factor, are determined. The functionality of the system is tested under clinical conditions. Spectrally resolved signals of elastic scattering and fluorescence polarization images are detected both from the wound surface in vivo and from the bioptic material. The reliability of the method is proven by comparing the results with the data of histological studies.

  17. System level challenges of THz and mm-wave imaging systems

    NASA Astrophysics Data System (ADS)

    Tang, Adrian

    2016-05-01

    While THz and mm-wave imaging systems provide an interesting avenue for stand-off detection of concealed weapons and other threats without the need for ionizing radiation, there are many physical and technical obstacles which still prevent these systems from becoming commercially practical. This paper introduces the major issues for active and passive imaging including background masking, specular responses, and thermal equalization. Secondly, the paper discusses the prospects of radar imaging, and tradeoffs between system parameters such as transmit power, receiver sensitivity and phase noise, and how these parameters affect corresponding physical behavior including aperture size, resolution, penetration, and stand-off distance.

  18. Volumetric imaging system for the ionosphere (VISION)

    NASA Astrophysics Data System (ADS)

    Dymond, Kenneth F.; Budzien, Scott A.; Nicholas, Andrew C.; Thonnard, Stefan E.; Fortna, Clyde B.

    2002-01-01

    The Volumetric Imaging System for the Ionosphere (VISION) is designed to use limb and nadir images to reconstruct the three-dimensional distribution of electrons over a 1000 km wide by 500 km high slab beneath the satellite with 10 km x 10 km x 10 km voxels. The primary goal of the VISION is to map and monitor global and mesoscale (> 10 km) electron density structures, such as the Appleton anomalies and field-aligned irregularity structures. The VISION consists of three UV limb imagers, two UV nadir imagers, a dual frequency Global Positioning System (GPS) receiver, and a coherently emitting three frequency radio beacon. The limb imagers will observe the O II 83.4 nm line (daytime electron density), O I 135.6 nm line (nighttime electron density and daytime O density), and the N2 Lyman-Birge-Hopfield (LBH) bands near 143.0 nm (daytime N2 density). The nadir imagers will observe the O I 135.6 nm line (nighttime electron density and daytime O density) and the N2 LBH bands near 143.0 nm (daytime N2 density). The GPS receiver will monitor the total electron content between the satellite containing the VISION and the GPS constellation. The three frequency radio beacon will be used with ground-based receiver chains to perform computerized radio tomography below the satellite containing the VISION. The measurements made using the two radio frequency instruments will be used to validate the VISION UV measurements.

  19. Underwater modulated pulse laser imaging system

    NASA Astrophysics Data System (ADS)

    O'Connor, Shawn; Mullen, Linda J.; Cochenour, Brandon

    2014-05-01

    The detection and identification of underwater threats in coastal areas are of interest to the Navy. When identifying a potential target, both two-dimensional (amplitude versus position) and three-dimensional (amplitude and range versus position) information are important. Laser imaging in turbid coastal waters makes this task challenging due to absorption and scattering in both the forward and backward directions. Conventional imaging approaches to suppress scatter rely on a pulsed laser and a range-gated receiver or an intensity-modulated continuous wave laser and a coherent RF receiver. The modulated pulsed laser imaging system is a hybrid of these two approaches and uses RF intensity modulation on a short optical pulse. The result is an imaging system capable of simultaneously acquiring high-contrast images along with high-precision unambiguous ranges. A working modulated pulsed laser line scanner was constructed and tested with a custom-built transmitter, a large-bandwidth optical receiver, and a high-speed digitizing oscilloscope. The effectiveness of the modulation to suppress both backscatter and forward scatter, as applied to both magnitude and range images, is discussed.

  20. Advances in Small Animal Imaging Systems

    NASA Astrophysics Data System (ADS)

    Loudos, George K.

    2007-11-01

    The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to an increased interest in in vivo laboratory animal imaging during the past few years. For this purpose, new instrumentation, data acquisition strategies, and image processing and reconstruction techniques are being developed, researched and evaluated. The aim of this article is to give a short overview of the state of the art technologies for high resolution and high sensitivity molecular imaging techniques, primarily positron emission tomography (PET) and single photon emission computed tomography (SPECT). The basic needs of small animal imaging will be described. The evolution in instrumentation in the past two decades, as well as the commercially available systems will be overviewed. Finally, the new trends in detector technology and preliminary results from challenging applications will be presented. For more details a number of references are provided.

  1. Optical imaging module for astigmatic detection system.

    PubMed

    Wang, Wei-Min; Cheng, Chung-Hsiang; Molnar, Gabor; Hwang, Ing-Shouh; Huang, Kuang-Yuh; Danzebrink, Hans-Ulrich; Hwu, En-Te

    2016-05-01

    In this paper, an optical imaging module design for an astigmatic detection system (ADS) is presented. The module is based on a commercial optical pickup unit (OPU) and it contains a coaxial illuminant for illuminating a specimen. Furthermore, the imaging module facilitates viewing the specimen and the detection laser spot of the ADS with a lateral resolution of approximately 1 μm without requiring the removal of an element of the OPU. Two polarizers and one infrared filter are used to eliminate stray laser light in the OPU and stray light produced by the illuminant. Imaging modules designed for digital versatile disks (DVDs) and Blu-ray DVDs were demonstrated. Furthermore, the module can be used for imaging a small cantilever with approximate dimensions of 2 μm (width) × 5 μm (length), and therefore, it has the potential to be used in high-speed atomic force microscopy. PMID:27250434

  2. Quantitative performance assessments for neuromagnetic imaging systems.

    PubMed

    Koga, Ryo; Hiyama, Ei; Matsumoto, Takuya; Sekihara, Kensuke

    2013-01-01

    We have developed a Monte-Carlo simulation method to assess the performance of neuromagnetic imaging systems using two kinds of performance metrics: A-prime metric and spatial resolution. We compute these performance metrics for virtual sensor systems having 80, 160, 320, and 640 sensors, and discuss how the system performance is improved, depending on the number of sensors. We also compute these metrics for existing whole-head MEG systems, MEGvision™ (Yokogawa Electric Corporation, Tokyo, Japan) that uses axial-gradiometer sensors, and TRIUX™ (Elekta Corporate, Stockholm, Sweden) that uses planar-gradiometer and magnetometer sensors. We discuss performance comparisons between these significantly different systems.

  3. Quantitative performance assessments for neuromagnetic imaging systems.

    PubMed

    Koga, Ryo; Hiyama, Ei; Matsumoto, Takuya; Sekihara, Kensuke

    2013-01-01

    We have developed a Monte-Carlo simulation method to assess the performance of neuromagnetic imaging systems using two kinds of performance metrics: A-prime metric and spatial resolution. We compute these performance metrics for virtual sensor systems having 80, 160, 320, and 640 sensors, and discuss how the system performance is improved, depending on the number of sensors. We also compute these metrics for existing whole-head MEG systems, MEGvision™ (Yokogawa Electric Corporation, Tokyo, Japan) that uses axial-gradiometer sensors, and TRIUX™ (Elekta Corporate, Stockholm, Sweden) that uses planar-gradiometer and magnetometer sensors. We discuss performance comparisons between these significantly different systems. PMID:24110711

  4. Wide field strip-imaging optical system

    NASA Technical Reports Server (NTRS)

    Vaughan, Arthur H. (Inventor)

    1994-01-01

    A strip imaging wide angle optical system is provided. The optical system is provided with a 'virtual' material stop to avoid aberrational effects inherent in wide angle optical systems. The optical system includes a spherical mirror section for receiving light from a 180-degree strip or arc of a target image. Light received by the spherical mirror section is reflected to a frusto-conical mirror section for subsequent rereflection to a row of optical fibers. Each optical fiber transmits a portion of the received light to a detector. The optical system exploits the narrow cone of acceptance associated with optical fibers to substantially eliminate vignetting effects inherent in wide-angle systems. Further, the optical system exploits the narrow cone of acceptance of the optical fibers to substantially limit spherical aberration. The optical system is ideally suited for any application wherein a 180-degree strip image need be detected, and is particularly well adapted for use in hostile environments such as in planetary exploration.

  5. Information efficiency in hyperspectral imaging systems

    NASA Astrophysics Data System (ADS)

    Reichenbach, Stephen E.; Cao, Luyin; Narayanan, Ram M.

    2002-07-01

    In this work we develop a method for assessing the information density and efficiency of hyperspectral imaging systems that have spectral bands of nonuniform width. Imaging system designs with spectral bands of nonuniform width can efficiently gather information about a scene by allocating bandwidth among the bands according to their information content. The information efficiency is the ratio of information density to data density and is a function of the scene's spectral radiance, hyperspectral system design, and signal-to-noise ratio. The assessment can be used to produce an efficient system design. For example, one approach to determining the number and width of the spectral bands for an information-efficient design is to begin with a design that has a single band and then to iteratively divide a band into two bands until no further division improves the system's efficiency. Two experiments illustrate this approach, one using a simple mathematical model for the scene spectral-radiance autocorrelation function and the other using the deterministic spectral-radiance autocorrelation function of a hyperspectral image from NASA's Advanced Solid-State Array Spectroradiometer. The approach could be used either to determine a fixed system design or to dynamically control a system with variable-width spectral bands (e.g., using on-board processing in a satellite system).

  6. Earth Penetration Radar Imaging System (EPRIS)

    NASA Astrophysics Data System (ADS)

    1993-08-01

    The Earth Penetration Radar Imaging System (EPRIS) has been developed and has the capability to detect and locate buried mines, buried ordnance delivered by precision munitions, buried drums, buried waste/contaminants, and geological structures/features. The detected objects or features are mapped in three dimensions with high resolution. This information is then available for integration into a site characterization study. The EPRIS is a significant improvement in non-intrusive sensing and imaging capability. This phase of the EPRIS development has been extremely successful. Coleman Research Corporation (CRC) has implemented significant advances in technology into the EPRIS equipment. The frequency stepped radar sensor design has a very wide dynamic signal range and improved sensitivity over currently available equipment. The two- and three-dimensional image processing algorithms allow high-resolution placement and sizing of buried objects and/or features. The discussions related to the analog-to-digital converter and the spiral antenna, define the source of the dynamic range capability realized by EPRIS. The processing for this new radar makes use of unique synthetic aperature imaging (SAI) algorithms developed by CRC for frequency stepped radar systems. The SAI algorithms are necessary to obtain excellent spatial resolution on objects buried up to seven meters. The sensor signal processing represents a significant improvement in imaging systems. The CRC test facility permitted tests on objects buried up to 2.44 meters.

  7. Parallel asynchronous systems and image processing algorithms

    NASA Technical Reports Server (NTRS)

    Coon, D. D.; Perera, A. G. U.

    1989-01-01

    A new hardware approach to implementation of image processing algorithms is described. The approach is based on silicon devices which would permit an independent analog processing channel to be dedicated to evey pixel. A laminar architecture consisting of a stack of planar arrays of the device would form a two-dimensional array processor with a 2-D array of inputs located directly behind a focal plane detector array. A 2-D image data stream would propagate in neuronlike asynchronous pulse coded form through the laminar processor. Such systems would integrate image acquisition and image processing. Acquisition and processing would be performed concurrently as in natural vision systems. The research is aimed at implementation of algorithms, such as the intensity dependent summation algorithm and pyramid processing structures, which are motivated by the operation of natural vision systems. Implementation of natural vision algorithms would benefit from the use of neuronlike information coding and the laminar, 2-D parallel, vision system type architecture. Besides providing a neural network framework for implementation of natural vision algorithms, a 2-D parallel approach could eliminate the serial bottleneck of conventional processing systems. Conversion to serial format would occur only after raw intensity data has been substantially processed. An interesting challenge arises from the fact that the mathematical formulation of natural vision algorithms does not specify the means of implementation, so that hardware implementation poses intriguing questions involving vision science.

  8. Active constraint control for image-guided robotic surgery.

    PubMed

    Yen, P-L; Davies, B L

    2010-01-01

    The concept of active constraint control for image-guided robotic surgery is introduced, together with its benefits and a short outline of its history. The clinical use of active constraint control in orthopaedic surgery is discussed, together with the outcomes of a clinical trial for unicondylar knee replacement surgery. The evolution of the robotic design from large costly structures towards simpler, more cost-effective systems is also presented, leading to the design of the Acrobot 'Sculptor' system. A new approach to the achievement of robotic total knee replacement is also presented, in which a high-speed rotary cutter is used to slice through the bone to achieve a speedy resection. The control concept is presented, together with the results of trials on animal bones and a cadaver, showing that it is possible to remove large quantities of bone both quickly and accurately.

  9. Image analysis to measure activity index of animals.

    PubMed

    Bloemen, H; Aerts, J M; Berckmans, D; Goedseels, V

    1997-05-01

    The objective of the study was to present a method to quantify the behavioural response of animals to their micro-environment by using a camera system and a digitiser board. An algorithm was developed for analysing images and calculating activity, occupied zone and boundary of the animals. The developed method was tested on 3 different applications and animals. In the first application, the behavioural responses of broiler chickens to their thermal environment was measured. In the second application behavioural responses of pigs to their thermal environment were measured. In the third application, the response of water fleas to a chromium pollution was measured using the developed technique. Based on the experimental results, it can be concluded that the developed image analysis technique can be employed to quantify the behavioural responses of the tested animals to their micro-environment, in an easy and accurate way.

  10. Thermal neutron imaging in an active interrogation environment

    SciTech Connect

    Vanier,P.E.; Forman, L., and Norman, D.R.

    2009-03-10

    We have developed a thermal-neutron coded-aperture imager that reveals the locations of hydrogenous materials from which thermal neutrons are being emitted. This imaging detector can be combined with an accelerator to form an active interrogation system in which fast neutrons are produced in a heavy metal target by means of xcitation by high energy photons. The photo-induced neutrons can be either prompt or delayed, depending on whether neutronemitting fission products are generated. Provided that there are hydrogenous materials close to the target, some of the photo-induced neutrons slow down and emerge from the surface at thermal energies. These neutrons can be used to create images that show the location and shape of the thermalizing materials. Analysis of the temporal response of the neutron flux provides information about delayed neutrons from induced fission if there are fissionable materials in the target. The combination of imaging and time-of-flight discrimination helps to improve the signal-to-background ratio. It is also possible to interrogate the target with neutrons, for example using a D-T generator. In this case, an image can be obtained from hydrogenous material in a target without the presence of heavy metal. In addition, if fissionable material is present in the target, probing with fast neutrons can stimulate delayed neutrons from fission, and the imager can detect and locate the object of interest, using appropriate time gating. Operation of this sensitive detection equipment in the vicinity of an accelerator presents a number of challenges, because the accelerator emits electromagnetic interference as well as stray ionizing radiation, which can mask the signals of interest.

  11. Active State Model for Autonomous Systems

    NASA Technical Reports Server (NTRS)

    Park, Han; Chien, Steve; Zak, Michail; James, Mark; Mackey, Ryan; Fisher, Forest

    2003-01-01

    The concept of the active state model (ASM) is an architecture for the development of advanced integrated fault-detection-and-isolation (FDI) systems for robotic land vehicles, pilotless aircraft, exploratory spacecraft, or other complex engineering systems that will be capable of autonomous operation. An FDI system based on the ASM concept would not only provide traditional diagnostic capabilities, but also integrate the FDI system under a unified framework and provide mechanism for sharing of information between FDI subsystems to fully assess the overall health of the system. The ASM concept begins with definitions borrowed from psychology, wherein a system is regarded as active when it possesses self-image, self-awareness, and an ability to make decisions itself, such that it is able to perform purposeful motions and other transitions with some degree of autonomy from the environment. For an engineering system, self-image would manifest itself as the ability to determine nominal values of sensor data by use of a mathematical model of itself, and selfawareness would manifest itself as the ability to relate sensor data to their nominal values. The ASM for such a system may start with the closed-loop control dynamics that describe the evolution of state variables. As soon as this model was supplemented with nominal values of sensor data, it would possess self-image. The ability to process the current sensor data and compare them with the nominal values would represent self-awareness. On the basis of self-image and self-awareness, the ASM provides the capability for self-identification, detection of abnormalities, and self-diagnosis.

  12. The magnetic resonance imaging-linac system.

    PubMed

    Lagendijk, Jan J W; Raaymakers, Bas W; van Vulpen, Marco

    2014-07-01

    The current image-guided radiotherapy systems are suboptimal in the esophagus, pancreas, kidney, rectum, lymph node, etc. These locations in the body are not easily accessible for fiducials and cannot be visualized sufficiently on cone-beam computed tomographies, making daily patient set-up prone to geometrical uncertainties and hinder dose optimization. Additional interfraction and intrafraction uncertainties for those locations arise from motion with breathing and organ filling. To allow real-time imaging of all patient tumor locations at the actual treatment position a fully integrated 1.5-T, diagnostic quality, magnetic resonance imaging with a 6-MV linear accelerator is presented. This system must enable detailed dose painting at all body locations. PMID:24931095

  13. Performance metrics for an airborne imaging system

    NASA Astrophysics Data System (ADS)

    Dayton, David C.; Gonglewski, John D.

    2004-11-01

    A series of airborne imaging experiments have been conducted on the island of Maui and at North Oscura Peak in New Mexico. Two platform altitudes were considered 3000 meters and 600 meters, both with a slant range to the target up to 10000 meters. The airborne imaging platform was a Twin Otter aircraft, which circled ground target sites. The second was a fixed platform on a mountain peak overlooking a valley 600 meters below. The experiments were performed during the day using solar illuminated target buildings. Imaging system performance predictions were calculated using standard atmospheric turbulence models, and aircraft boundary layer models. Several different measurement approaches were then used to estimate the actual system performance, and make comparisons with the calculations.

  14. Stereo Imaging Velocimetry System and Method

    NASA Technical Reports Server (NTRS)

    McDowell, Mark (Inventor)

    2003-01-01

    A system and a method is provided for measuring three dimensional velocities at a plurality of points in a fluid employing at least two cameras positioned approximately perpendicular to one another. Image frames captured by the cameras may be filtered using background subtraction with outlier rejection with spike-removal filtering. The cameras may calibrated to accurately represent image coordinates in a world coordinate system using calibration grids modified using warp transformations. The two-dimensional views of the cameras may be recorded fur image processing and particle track determination. The tracer particles may be tracked on a two-dimensional basis and then stereo matched to obtain three-dimensional locations of the particles as a function of time so that velocities can be measured there from.

  15. Ultrafast optics: Imaging and manipulating biological systems

    NASA Astrophysics Data System (ADS)

    Sheetz, Kraig E.; Squier, Jeff

    2009-03-01

    The rapid evolution of ultrafast optics technology over the past two decades has opened the window to a broad range of applications in biology and medicine. Compact, reliable, and turn-key ultrafast laser systems are enabling cutting-edge science to take place in everyday laboratories and clinics. Led by the discovery of two-photon excitation fluorescence microscopy nearly 20 years ago, the biological imaging community is exploring unique image contrast mechanisms and pushing spatial and temporal resolution to new limits. Concurrent with advancements in imaging are developments in the precision application of extremely high peak intensities available in ultrashort pulses for disrupting or manipulating targeted locations in biological systems on the submicron scale while leaving surrounding tissue healthy. The ability for scientists to selectively discriminate structures of interest at the cellular and subcellular levels under relevant physiological conditions shows tremendous promise for accelerating the path to understanding biological functions at the most fundamental level.

  16. Acousto-optic tunable filter multispectral imaging system

    NASA Technical Reports Server (NTRS)

    Cheng, Li-Jen; Chao, Tien-Hsin; Reyes, George

    1992-01-01

    This paper discusses recent activities of Jet Propulsion Laboratory in the development of a new type of remote sensing multispectral imaging instruments using acousto-optic tunable filter (AOTF) as programmable bandpass filter. This remote sensor provides real-time operation; observational flexibility; measurements of spectral, spatial, and polarization information using a single instrument; and compact, solid state structure without moving parts. Two microcomputer-controlled AOTF imaging spectrometer breadboard systems were designed and built. One operates in the wavelength range of 0.48-0.76 micron and the other in the range of 1.2-2.5 micron. Experiments were performed using these two systems to observe geological and botanical objects in laboratory and outdoor environment. Results have demonstrated the feasibility of using the AOTF multispectral imaging system as a real-time versatile remote sensor with operational flexibility for future Army tactical applications.

  17. Bioluminescence imaging of estrogen receptor activity during breast cancer progression.

    PubMed

    Vantaggiato, Cristina; Dell'Omo, Giulia; Ramachandran, Balaji; Manni, Isabella; Radaelli, Enrico; Scanziani, Eugenio; Piaggio, Giulia; Maggi, Adriana; Ciana, Paolo

    2016-01-01

    Estrogen receptors (ER) are known to play an important regulatory role in mammary gland development as well as in its neoplastic transformation. Although several studies highlighted the contribution of ER signaling in the breast transformation, little is known about the dynamics of ER state of activity during carcinogenesis due to the lack of appropriate models for measuring the extent of receptor signaling in time, in the same animal. To this aim, we have developed a reporter mouse model for the non-invasive in vivo imaging of ER activity: the ERE-Luc reporter mouse. ERE-Luc is a transgenic mouse generated with a firefly luciferase (Luc) reporter gene driven by a minimal promoter containing an estrogen responsive element (ERE). This model allows to measure receptor signaling in longitudinal studies by bioluminescence imaging (BLI). Here, we have induced sporadic mammary cancers by treating systemically ERE-Luc reporter mice with DMBA (9,10-dimethyl 1,2-benzanthracene) and measured receptor signaling by in vivo imaging in individual animals from early stage until a clinically palpable tumor appeared in the mouse breast. We showed that DMBA administration induces an increase of bioluminescence in the whole abdominal area 6 h after treatment, the signal rapidly disappears. Several weeks later, strong bioluminescence is observed in the area corresponding to the mammary glands. In vivo and ex vivo imaging analysis demonstrated that this bioluminescent signal is localized in the breast area undergoing neoplastic transformation. We conclude that this non-invasive assay is a novel relevant tool to identify the activation of the ER signaling prior the morphological detection of the neoplastic transformation. PMID:27069764

  18. Bioluminescence imaging of estrogen receptor activity during breast cancer progression.

    PubMed

    Vantaggiato, Cristina; Dell'Omo, Giulia; Ramachandran, Balaji; Manni, Isabella; Radaelli, Enrico; Scanziani, Eugenio; Piaggio, Giulia; Maggi, Adriana; Ciana, Paolo

    2016-01-01

    Estrogen receptors (ER) are known to play an important regulatory role in mammary gland development as well as in its neoplastic transformation. Although several studies highlighted the contribution of ER signaling in the breast transformation, little is known about the dynamics of ER state of activity during carcinogenesis due to the lack of appropriate models for measuring the extent of receptor signaling in time, in the same animal. To this aim, we have developed a reporter mouse model for the non-invasive in vivo imaging of ER activity: the ERE-Luc reporter mouse. ERE-Luc is a transgenic mouse generated with a firefly luciferase (Luc) reporter gene driven by a minimal promoter containing an estrogen responsive element (ERE). This model allows to measure receptor signaling in longitudinal studies by bioluminescence imaging (BLI). Here, we have induced sporadic mammary cancers by treating systemically ERE-Luc reporter mice with DMBA (9,10-dimethyl 1,2-benzanthracene) and measured receptor signaling by in vivo imaging in individual animals from early stage until a clinically palpable tumor appeared in the mouse breast. We showed that DMBA administration induces an increase of bioluminescence in the whole abdominal area 6 h after treatment, the signal rapidly disappears. Several weeks later, strong bioluminescence is observed in the area corresponding to the mammary glands. In vivo and ex vivo imaging analysis demonstrated that this bioluminescent signal is localized in the breast area undergoing neoplastic transformation. We conclude that this non-invasive assay is a novel relevant tool to identify the activation of the ER signaling prior the morphological detection of the neoplastic transformation.

  19. Imaging Systems For Application In Harsh Environments

    NASA Astrophysics Data System (ADS)

    Grothues, H.-G.; Michaelis, H.; Behnke, T.; Bresch, W.; Koldewey, E.; Lichopoj, A.; Tschentscher, M.; Alicke, P.

    Imaging systems operating in the wavelength domain between the near UV and the mid IR (about 300 nm to > 5 (m) play a crucial role in remote sensing from orbiters and in-situ lander measurements of planetary exploration space missions. Wide-angle and high-resolution cameras, IR imagers, and imaging spectrographs provide carto- graphic information on the morphology and topography of planetary surfaces, serve to characterize landing sites with their geological features like soils and rocks, de- liver data on the spectrophotometric characteristics of minerals, and contribute to at- mospheric reasearch. Moreover, imaging systems have the important task to present scientific missions to the general public. As resources during planetary missions are usually very limited imaging payloads have to be designed to have low mass and size, low power consumption, and to effectively handle the imaging data taking into ac- count the limited computing powers, mass memories and telemetry data rates (image data compression). Furthermore, the design has to cope with extremely harsh environ- ments such as, for example, high and very low temperatures, large temperature varia- tions and gradients, high mechanical loads (shocks), e.g. during landing on a planetary surface, a hostile particle radiation environment, and dusty or chemically aggressive atmospheres. The presentation discusses the requirements to be set up for planetary mission imaging systems, and gives an overview of the most important design mea- sures to be taken in order to be compliant with these requirements (e.g. miniatur- ization of electronics, light-weight materials, athermal and radiation tolerant design). The discussion comprises all subunits of imaging systems starting with the optics / the spectrograph and the detector unit, continuing with the data processing unit, and ending with peripheral equipment like e.g. drives, deployable booms, and illumina- tion devices for lander cameras. Examples are given of already

  20. Active contours for localizing polyps in colonoscopic NBI image data

    NASA Astrophysics Data System (ADS)

    Breier, Matthias; Gross, Sebastian; Behrens, Alexander; Stehle, Thomas; Aach, Til

    2011-03-01

    Colon cancer is the third most common type of cancer in the United States of America. Every year about 140,000 people are newly diagnosed with colon cancer. Early detection is crucial for a successful therapy. The standard screening procedure is called colonoscopy. Using this endoscopic examination physicians can find colon polyps and remove them if necessary. Adenomatous colon polyps are deemed a preliminary stage of colon cancer. The removal of a polyp, though, can lead to complications like severe bleedings or colon perforation. Thus, only polyps diagnosed as adenomatous should be removed. To decide whether a polyp is adenomatous the polyp's surface structure including vascular patterns has to be inspected. Narrow-Band imaging (NBI) is a new tool to improve visibility of vascular patterns of the polyps. The first step for an automatic polyp classification system is the localization of the polyp. We investigate active contours for the localization of colon polyps in NBI image data. The shape of polyps, though roughly approximated by an elliptic form, is highly variable. Active contours offer the flexibility to adapt to polyp variation well. To avoid clustering of contour polygon points we propose the application of active rays. The quality of the results was evaluated based on manually segmented polyps as ground truth data. The results were compared to a template matching approach and to the Generalized Hough Transform. Active contours are superior to the Hough transform and perform equally well as the template matching approach.

  1. Echocardiographic image of an active human heart

    NASA Technical Reports Server (NTRS)

    2003-01-01

    Echocardiographic images provide quick, safe images of the heart as it beats. While a state-of-the art echocardiograph unit is part of the Human Research Facility on International Space Station, quick transmission of images and data to Earth is a challenge. NASA is developing techniques to improve the echocardiography available to diagnose sick astronauts as well as study the long-term effects of space travel on their health. Echocardiography uses ultrasound, generated in a sensor head placed against the patient's chest, to produce images of the structure of the heart walls and valves. However, ultrasonic imaging creates an enormous volume of data, up to 220 million bits per second. This can challenge ISS communications as well as Earth-based providers. Compressing data for rapid transmission back to Earth can degrade the quality of the images. Researchers at the Cleveland Clinic Foundation are working with NASA to develop compression techniques that meet imaging standards now used on the Internet and by the medical community, and that ensure that physicians receive quality diagnostic images.

  2. Miniaturized Airborne Imaging Central Server System

    NASA Technical Reports Server (NTRS)

    Sun, Xiuhong

    2011-01-01

    In recent years, some remote-sensing applications require advanced airborne multi-sensor systems to provide high performance reflective and emissive spectral imaging measurement rapidly over large areas. The key or unique problem of characteristics is associated with a black box back-end system that operates a suite of cutting-edge imaging sensors to collect simultaneously the high throughput reflective and emissive spectral imaging data with precision georeference. This back-end system needs to be portable, easy-to-use, and reliable with advanced onboard processing. The innovation of the black box backend is a miniaturized airborne imaging central server system (MAICSS). MAICSS integrates a complex embedded system of systems with dedicated power and signal electronic circuits inside to serve a suite of configurable cutting-edge electro- optical (EO), long-wave infrared (LWIR), and medium-wave infrared (MWIR) cameras, a hyperspectral imaging scanner, and a GPS and inertial measurement unit (IMU) for atmospheric and surface remote sensing. Its compatible sensor packages include NASA s 1,024 1,024 pixel LWIR quantum well infrared photodetector (QWIP) imager; a 60.5 megapixel BuckEye EO camera; and a fast (e.g. 200+ scanlines/s) and wide swath-width (e.g., 1,920+ pixels) CCD/InGaAs imager-based visible/near infrared reflectance (VNIR) and shortwave infrared (SWIR) imaging spectrometer. MAICSS records continuous precision georeferenced and time-tagged multisensor throughputs to mass storage devices at a high aggregate rate, typically 60 MB/s for its LWIR/EO payload. MAICSS is a complete stand-alone imaging server instrument with an easy-to-use software package for either autonomous data collection or interactive airborne operation. Advanced multisensor data acquisition and onboard processing software features have been implemented for MAICSS. With the onboard processing for real time image development, correction, histogram-equalization, compression, georeference, and

  3. Multi-spectral image dissector camera system

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The image dissector sensor for the Earth Resources Program is evaluated using contrast and reflectance data. The ground resolution obtainable for low contrast at the targeted signal to noise ratio of 1.8 was defined. It is concluded that the system is capable of achieving the detection of small, low contrast ground targets from satellites.

  4. Miniaturized 3D microscope imaging system

    NASA Astrophysics Data System (ADS)

    Lan, Yung-Sung; Chang, Chir-Weei; Sung, Hsin-Yueh; Wang, Yen-Chang; Chang, Cheng-Yi

    2015-05-01

    We designed and assembled a portable 3-D miniature microscopic image system with the size of 35x35x105 mm3 . By integrating a microlens array (MLA) into the optical train of a handheld microscope, the biological specimen's image will be captured for ease of use in a single shot. With the light field raw data and program, the focal plane can be changed digitally and the 3-D image can be reconstructed after the image was taken. To localize an object in a 3-D volume, an automated data analysis algorithm to precisely distinguish profundity position is needed. The ability to create focal stacks from a single image allows moving or specimens to be recorded. Applying light field microscope algorithm to these focal stacks, a set of cross sections will be produced, which can be visualized using 3-D rendering. Furthermore, we have developed a series of design rules in order to enhance the pixel using efficiency and reduce the crosstalk between each microlens for obtain good image quality. In this paper, we demonstrate a handheld light field microscope (HLFM) to distinguish two different color fluorescence particles separated by a cover glass in a 600um range, show its focal stacks, and 3-D position.

  5. Functional imaging of the musculoskeletal system.

    PubMed

    Griffith, James F

    2015-06-01

    Functional imaging, which provides information of how tissues function rather than structural information, is well established in neuro- and cardiac imaging. Many musculoskeletal structures, such as ligaments, fascia and mineralized bone, have by definition a mainly structural role and clearly don't have the same functional capacity as the brain, heart, liver or kidney. The main functionally responsive musculoskeletal tissues are the bone marrow, muscle and nerve and, as such, magnetic resonance (MR) functional imaging has primarily addressed these areas. Proton or phosphorus spectroscopy, other fat quantification techniques, perfusion imaging, BOLD imaging, diffusion and diffusion tensor imaging (DTI) are the main functional techniques applied. The application of these techniques in the musculoskeletal system has mainly been research orientated where they have already greatly enhanced our understanding of marrow physiology, muscle physiology and neural function. Going forwards, they will have a greater clinical impact helping to bridge the disconnect often seen between structural appearances and clinical symptoms, allowing a greater understanding of disease processes and earlier recognition of disease, improving prognostic prediction and optimizing the monitoring of treatment effect. PMID:26029633

  6. Current Status of Optical Imaging for Evaluating Lymph Nodes and Lymphatic System

    PubMed Central

    Lee, Eun Seong; Kim, Tae Sung

    2015-01-01

    Optical imaging techniques use visual and near infrared rays. Despite their considerably poor penetration depth, they are widely used due to their safe and intuitive properties and potential for intraoperative usage. Optical imaging techniques have been actively investigated for clinical imaging of lymph nodes and lymphatic system. This article summarizes a variety of optical tracers and techniques used for lymph node and lymphatic imaging, and reviews their clinical applications. Emerging new optical imaging techniques and their potential are also described. PMID:25598672

  7. A recommender system for medical imaging diagnostic.

    PubMed

    Monteiro, Eriksson; Valente, Frederico; Costa, Carlos; Oliveira, José Luís

    2015-01-01

    The large volume of data captured daily in healthcare institutions is opening new and great perspectives about the best ways to use it towards improving clinical practice. In this paper we present a context-based recommender system to support medical imaging diagnostic. The system relies on data mining and context-based retrieval techniques to automatically lookup for relevant information that may help physicians in the diagnostic decision.

  8. The imaging node for the Planetary Data System

    USGS Publications Warehouse

    Eliason, E.M.; LaVoie, S.K.; Soderblom, L.A.

    1996-01-01

    The Planetary Data System Imaging Node maintains and distributes the archives of planetary image data acquired from NASA's flight projects with the primary goal of enabling the science community to perform image processing and analysis on the data. The Node provides direct and easy access to the digital image archives through wide distribution of the data on CD-ROM media and on-line remote-access tools by way of Internet services. The Node provides digital image processing tools and the expertise and guidance necessary to understand the image collections. The data collections, now approaching one terabyte in volume, provide a foundation for remote sensing studies for virtually all the planetary systems in our solar system (except for Pluto). The Node is responsible for restoring data sets from past missions in danger of being lost. The Node works with active flight projects to assist in the creation of their archive products and to ensure that their products and data catalogs become an integral part of the Node's data collections.

  9. The Airborne Ocean Color Imager - System description and image processing

    NASA Technical Reports Server (NTRS)

    Wrigley, Robert C.; Slye, Robert E.; Klooster, Steven A.; Freedman, Richard S.; Carle, Mark; Mcgregor, Lloyd F.

    1992-01-01

    The Airborne Ocean Color Imager was developed as an aircraft instrument to simulate the spectral and radiometric characteristics of the next generation of satellite ocean color instrumentation. Data processing programs have been developed as extensions of the Coastal Zone Color Scanner algorithms for atmospheric correction and bio-optical output products. The latter include several bio-optical algorithms for estimating phytoplankton pigment concentration, as well as one for the diffuse attenuation coefficient of the water. Additional programs have been developed to geolocate these products and remap them into a georeferenced data base, using data from the aircraft's inertial navigation system. Examples illustrate the sequential data products generated by the processing system, using data from flightlines near the mouth of the Mississippi River: from raw data to atmospherically corrected data, to bio-optical data, to geolocated data, and, finally, to georeferenced data.

  10. Polarization sensitive optical frequency domain imaging system for endobronchial imaging.

    PubMed

    Li, Jianan; Feroldi, Fabio; de Lange, Joop; Daniels, Johannes M A; Grünberg, Katrien; de Boer, Johannes F

    2015-02-01

    A polarization sensitive endoscopic optical frequency domain imaging (PS-OFDI) system with a motorized distal scanning catheter is demonstrated. It employs a passive polarization delay unit to multiplex two orthogonal probing polarization states in depth, and a polarization diverse detection unit to detect interference signal in two orthogonal polarization channels. Per depth location four electro-magnetic field components are measured that can be represented in a complex 2x2 field matrix. A Jones matrix of the sample is derived and the sample birefringence is extracted by eigenvalue decomposition. The condition of balanced detection and the polarization mode dispersion are quantified. A complex field averaging method based on the alignment of randomly pointing field phasors is developed to reduce speckle noise. The variation of the polarization states incident on the tissue due to the circular scanning and catheter sheath birefringence is investigated. With this system we demonstrated imaging of ex vivo chicken muscle, in vivo pig lung and ex vivo human lung specimens. PMID:25836196

  11. W-band active imaging by photonics-based synthesizer

    NASA Astrophysics Data System (ADS)

    Kanno, Atsushi; Sekine, Norihiko; Kasamatsu, Akifumi; Yamamoto, Naokatsu

    2016-05-01

    We demonstrate a nondestructive electromagnetic-wave imaging system with a photonics-based W-band synthe- sizer, traveling-wave tube amplifier and focal-plane transistor array in real time manner. High-power amplifier with multi-watts output will enhance the quality of obtained images under transmission and reflection imaging configurations.

  12. MONSOON: Image Acquisition System or "Pixel Server"

    NASA Astrophysics Data System (ADS)

    Starr, Barry M.; Buchholz, Nick C.; Rahmer, Gustavo; Penegor, Gerald; Schmidt, Ricardo E.; Warner, Michael; Merrill, Michael; Claver, Charles F.; Ho, Y.; Chopra, K. N.; Shroff, C.; Shroff, D.

    2003-03-01

    The MONSOON Image Acquisition System has been designed to meet the need for scalable, multichannel, high-speed image acquisition required for the next-generation optical and infared detectors and mosaic projects currently under development at NOAO as described in other papers at this proceeding such as ORION, NEWFIRM, QUOTA, ODI and LSST. These new systems with their large scale (64 to 2000 channels) and high performance (up to 1Gbyte/s) raise new challenges in terms of communication bandwidth, data storage and data processing requirements which are not adequately met by existing astronomical controllers. In order to meet this demand, new techniques for not only a new detector controller, but rather a new image acquisition architecture, have been defined. These extremely large scale imaging systems also raise less obvious concerns in previously neglected areas of controller design such as physical size and form factor issues, power dissipation and cooling near the telescope, system assembly/test/ integration time, reliability, and total cost of ownership. At NOAO we have taken efforts to look outside of the astronomical community for solutions found in other disciplines to similar classes of problems. A large number of the challenges raised by these system needs are already successfully being faced in other areas such as telecommunications, instrumentation and aerospace. Efforts have also been made to use true commercial off the shelf (COTS) system elements, and find truly technology independent solutions for a number of system design issues whenever possible. The Monsoon effort is a full-disclosure development effort by NOAO in collaboration with the CARA ASTEROID project for the benefit of the astronomical community.

  13. Imaging system considerations in Doppler global velocimetry

    SciTech Connect

    Ford, H.D.; Tatam, R.P.

    1995-12-31

    Doppler Global Velocimetry (DGV) is a full-field optical technique for the measurement of fluid flow velocities. The flow is illuminated using a light sheet, and the Doppler shift imposed on light scattered from moving particles within the sheet is imaged through a cell containing iodine vapor onto a solid-state array camera, thereby converting the Doppler frequency shifts into intensity variations in the image. In this paper, a DGV system is presented based around an argon-ion laser source and a fast digital image-processing system, which allows the DGV velocity map to be updated at camera frame rate. Interpretation of DGV images is complicated by errors which arise at positions some way out in the field of view due to the modified illumination and viewing vectors corresponding to these positions. Typical magnitudes of such errors are calculated. Significant errors can arise for points more than about 5{degree} out from the center of the field of view, and for divergence angles of the illumination beam exceeding about 10{degree} at a distance of 5 cm from the beam axis. Other considerations affecting system accuracy are also discussed.

  14. Color Image Processing and Object Tracking System

    NASA Technical Reports Server (NTRS)

    Klimek, Robert B.; Wright, Ted W.; Sielken, Robert S.

    1996-01-01

    This report describes a personal computer based system for automatic and semiautomatic tracking of objects on film or video tape, developed to meet the needs of the Microgravity Combustion and Fluids Science Research Programs at the NASA Lewis Research Center. The system consists of individual hardware components working under computer control to achieve a high degree of automation. The most important hardware components include 16-mm and 35-mm film transports, a high resolution digital camera mounted on a x-y-z micro-positioning stage, an S-VHS tapedeck, an Hi8 tapedeck, video laserdisk, and a framegrabber. All of the image input devices are remotely controlled by a computer. Software was developed to integrate the overall operation of the system including device frame incrementation, grabbing of image frames, image processing of the object's neighborhood, locating the position of the object being tracked, and storing the coordinates in a file. This process is performed repeatedly until the last frame is reached. Several different tracking methods are supported. To illustrate the process, two representative applications of the system are described. These applications represent typical uses of the system and include tracking the propagation of a flame front and tracking the movement of a liquid-gas interface with extremely poor visibility.

  15. An improved active imaging method for upgrading low-light-level image detection sensitivity

    NASA Astrophysics Data System (ADS)

    Tang, Hongying

    2013-09-01

    Active imaging is an essential tool for low-light-level imaging. However, it has some drawbacks, such as limited imaging range and lack of security. We optimize the imaging approach by casting a saw-tooth wave auxiliary light signal over the sensor. Here, the auxiliary signal is superposed with a low-light-level signal, which is too weak to be measured by the sensor. After acquiring a superimposed image set in one saw-tooth wave circle, low-light-level image estimation is achieved by implementing least-square algorithm during data processing. This improved method not only makes active imaging overcome the drawbacks mentioned above, but also provides a feasible way to improve the low-light-level image detection sensitivity.

  16. Retroreflective imaging systems for enhanced optical biosensing

    NASA Astrophysics Data System (ADS)

    Bergen, Mark H.; Nichols, Jacqueline; Collier, Christopher M.; Jin, Xian; Holzman, Jonathan F.

    2014-05-01

    Biosensing is important for detection and characterization of microorganisms. When the detection and characterization of targeted microorganisms require micron-scale resolutions, optical biosensing techniques are especially beneficial. Optical biosensing can be applied through direct or indirect optical sensing techniques. The latter have demonstrated especially high sensitivities for the detection of targeted microorganisms with labeling. Unfortunately, such systems rely on high-resolution microscopy with microscopic sampling areas to image the labeled target microorganisms. This leads to long characterization times for applications such as pathogen detection in water quality monitoring where users must scan the micron-scale sampling areas across millimeter- or even centimeter-scale samples. This work introduces retroreflector labels for the detection and characterization of microorganisms for macroscopic sample sizes. The demonstrated retroreflective imaging system uses a laser source to illuminate the sample, in lieu of the fluorescent excitation source, and micron-scale retroreflector labels, in lieu of fluorescent stains/proteins. Antibodies are used to bind retroreflectors to targeted microorganisms. The presence of these microscopic retroreflector-microorganism pairs is monitored in a retroreflected image that is captured by a distant image sensor which shows a well-localized retroreflected beamspot for each pair. Characteristics of an appropriately-designed retroreflective imaging system which provide a quantifiable record of microorganism-coupled retroreflectors across macroscopic sample sizes are presented. Retroreflection directionality, collimation, and contrast are investigated for both corner-cube retroreflectors and spherical retroreflectors (of varying refractive indices). It is ultimately found that such a system is an effective tool for the detection and characterization of microorganism targets, down to a single-target detection limit.

  17. Terahertz imaging system performance model for concealed-weapon identification.

    PubMed

    Murrill, Steven R; Jacobs, Eddie L; Moyer, Steven K; Halford, Carl E; Griffin, Steven T; De Lucia, Frank C; Petkie, Douglas T; Franck, Charmaine C

    2008-03-20

    The U.S. Army Night Vision and Electronic Sensors Directorate (NVESD) and the U.S. Army Research Laboratory have developed a terahertz (THz) -band imaging system performance model for detection and identification of concealed weaponry. The MATLAB-based model accounts for the effects of all critical sensor and display components and for the effects of atmospheric attenuation, concealment material attenuation, and active illumination. The model is based on recent U.S. Army NVESD sensor performance modeling technology that couples system design parameters to observer-sensor field performance by using the acquire methodology for weapon identification performance predictions. This THz model has been developed in support of the Defense Advanced Research Project Agencies' Terahertz Imaging Focal-Plane Technology (TIFT) program and is currently being used to guide the design and development of a 0.650 THz active-passive imaging system. This paper will describe the THz model in detail, provide and discuss initial modeling results for a prototype THz imaging system, and outline plans to calibrate and validate the model through human perception testing. PMID:18709076

  18. System Matrix Analysis for Computed Tomography Imaging

    PubMed Central

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  19. Implantable imaging system for visual prosthesis.

    PubMed

    Zhou, Chuanqing; Tao, Chen; Chai, Xinyu; Sun, Yong; Ren, Qiushi

    2010-06-01

    In order to propose a method of intraocular imaging system for the visual prosthesis, an implantable microcamera was developed and evaluated in vivo. The microcamera was specially developed and shaped to fit the rabbit's lens capsule and encapsulated with the biocompatible silicone. To evaluate the feasibility of this novel approach, the custom-built device was implanted following the surgical extraction of rabbit's lens. And clinical examinations were performed 1 day, 3 days, 1 week, 2 week, and 1 month postoperatively, including slit-lamp examination, intraocular pressure, wound status, anterior chamber depth, the presence of the iris fibrosi of neovascularization, and the position of the implant. Real-time imaging was performed in vivo 1 month after the operation, and the acquired images were processed with the software and hardware that were specially developed for generating the stimulating pulses. Short-term results showed the novel approach is promising.

  20. System Matrix Analysis for Computed Tomography Imaging.

    PubMed

    Flores, Liubov; Vidal, Vicent; Verdú, Gumersindo

    2015-01-01

    In practical applications of computed tomography imaging (CT), it is often the case that the set of projection data is incomplete owing to the physical conditions of the data acquisition process. On the other hand, the high radiation dose imposed on patients is also undesired. These issues demand that high quality CT images can be reconstructed from limited projection data. For this reason, iterative methods of image reconstruction have become a topic of increased research interest. Several algorithms have been proposed for few-view CT. We consider that the accurate solution of the reconstruction problem also depends on the system matrix that simulates the scanning process. In this work, we analyze the application of the Siddon method to generate elements of the matrix and we present results based on real projection data. PMID:26575482

  1. Physiologic activities of the contact activation system.

    PubMed

    Schmaier, Alvin H

    2014-05-01

    The plasma contact activation (CAS) and kallikrein/kinin (KKS) systems consist of 4 proteins: factor XII, prekallikrein, high molecular weight kininogen, and the bradykinin B2 receptor. Murine genetic deletion of factor XII (F12(-/-)), prekallikrein (Klkb1(-/-)), high molecular weight kininogen (Kgn1(-/-)) and the bradykinin B2 receptor (Bdkrb2(-/-)) yield animals protected from thrombosis. With possible exception of F12(-/-) and Kgn1(-/-) mice, the mechanism(s) for thrombosis protection is not reduced contact activation. Bdkrb2(-/-) mice are best characterized and they are protected from thrombosis through over expression of components of the renin angiotensin system (RAS) leading to elevated prostacyclin with vascular and platelet inhibition. Alternatively, prolylcarboxypeptidase, a PK activator and degrader of angiotensin II, when deficient in the mouse leads to a prothrombotic state. Its mechanism for increased thrombosis also is mediated in part by components of the RAS. These observations suggest that thrombosis in mice of the CAS and KKS are mediated in part through the RAS and independent of reduced contact activation. PMID:24759141

  2. MIMO based 3D imaging system at 360 GHz

    NASA Astrophysics Data System (ADS)

    Herschel, R.; Nowok, S.; Zimmermann, R.; Lang, S. A.; Pohl, N.

    2016-05-01

    A MIMO radar imaging system at 360 GHz is presented as a part of the comprehensive approach of the European FP7 project TeraSCREEN, using multiple frequency bands for active and passive imaging. The MIMO system consists of 16 transmitter and 16 receiver antennas within one single array. Using a bandwidth of 30 GHz, a range resolution up to 5 mm is obtained. With the 16×16 MIMO system 256 different azimuth bins can be distinguished. Mechanical beam steering is used to measure 130 different elevation angles where the angular resolution is obtained by a focusing elliptical mirror. With this system a high resolution 3D image can be generated with 4 frames per second, each containing 16 million points. The principle of the system is presented starting from the functional structure, covering the hardware design and including the digital image generation. This is supported by simulated data and discussed using experimental results from a preliminary 90 GHz system underlining the feasibility of the approach.

  3. Map-guided image database system for remotely sensed data

    SciTech Connect

    Kondo, T.; Shinoda, H.; Sawada, N.; Numagami, H.; Kidode, M.

    1982-01-01

    The authors describes an image database system designed for the management of Landsat image data. In this system, all images are stored under a unique coordinate system (the goedesic coordinate system), accompanied with map information. The user can retrieve any part of the images in terms of geographical names and/or their attributes. This system is implemented on a high-performance interactive image processing system, where remotely sensed data analysis programs can be performed with the aid of a high speed image processor. Experimental results have proved that this system is useful enough to perform remote sensing studies. 5 references.

  4. Imaging beyond the striatonigral dopaminergic system in Parkinson's disease.

    PubMed

    Giza, Evangelia; Gotzamani-Psarrakou, Anna; Bostantjopoulou, Sevasti

    2012-01-01

    Parkinson 's disease (PD) is characterized by progressive loss of dopaminergic neurons in the nigrostriatal pathway, but this seems to constitute only part of the whole pathological process of the disease. Accumulating data have documented the concomitant degeneration of other dopaminergic pathways and of the serotonergic, cholinergic and noradrenergic neurotransmitter systems. In addition, pathologic process is not only restricted in the brain, since the spinal cord and the peripheral autonomic nervous system are also affected. The pathogenesis of PD remains unclear. The use of positron emission tomography and single photon emission tomography may contribute to the understanding of these aspects of the disease. This review will discuss the role of PET and SPET in imaging the extrastriatal dopaminergic system and other neurotransmitter systems as well as the imaging of microglial activation and cardiac sympathetic denervation in PD. In conclusion, several PET and SPET ligands can detect changes in extrastriatal dopaminergic system as well as in the serotonergic, cholinergic and noradrenergic systems in PD and also explore its possible correlation with motor and non motor symptoms. The use of PET scintigraphy allows the detection of microglial activation in PD, while (123)I-MIBG scintigraphy depicts cardiac sympathetic denervation in PD and is a useful imaging tool for differentiating PD from other types of parkinsonism.

  5. A new method of ICCD imaging system MRC measurement

    NASA Astrophysics Data System (ADS)

    Li, Sheng-cai; Jin, Wei-qi; Wang, Xia; Zhang, Wei-qiang; Dong, Hai-yan

    2005-02-01

    Based on analysis of the working principle of ICCD imaging system, the paper develops a new testing system for synthetic performance of ICCD imaging system. With the help of this testing system for integrative performance and the theory of Weibull psychometric function, a new method for MRC measurement of Space Light Modulation (SLM) is proposed, and the paper firstly implements measurement for minimum resolvable contrast performance of ICCD imaging system. The method provides reference for MRC performance measurement of other imaging system.

  6. High-resolution imaging using a wideband MIMO radar system with two distributed arrays.

    PubMed

    Wang, Dang-wei; Ma, Xiao-yan; Chen, A-Lei; Su, Yi

    2010-05-01

    Imaging a fast maneuvering target has been an active research area in past decades. Usually, an array antenna with multiple elements is implemented to avoid the motion compensations involved in the inverse synthetic aperture radar (ISAR) imaging. Nevertheless, there is a price dilemma due to the high level of hardware complexity compared to complex algorithm implemented in the ISAR imaging system with only one antenna. In this paper, a wideband multiple-input multiple-output (MIMO) radar system with two distributed arrays is proposed to reduce the hardware complexity of the system. Furthermore, the system model, the equivalent array production method and the imaging procedure are presented. As compared with the classical real aperture radar (RAR) imaging system, there is a very important contribution in our method that the lower hardware complexity can be involved in the imaging system since many additive virtual array elements can be obtained. Numerical simulations are provided for testing our system and imaging method.

  7. High-resolution imaging using a wideband MIMO radar system with two distributed arrays.

    PubMed

    Wang, Dang-wei; Ma, Xiao-yan; Chen, A-Lei; Su, Yi

    2010-05-01

    Imaging a fast maneuvering target has been an active research area in past decades. Usually, an array antenna with multiple elements is implemented to avoid the motion compensations involved in the inverse synthetic aperture radar (ISAR) imaging. Nevertheless, there is a price dilemma due to the high level of hardware complexity compared to complex algorithm implemented in the ISAR imaging system with only one antenna. In this paper, a wideband multiple-input multiple-output (MIMO) radar system with two distributed arrays is proposed to reduce the hardware complexity of the system. Furthermore, the system model, the equivalent array production method and the imaging procedure are presented. As compared with the classical real aperture radar (RAR) imaging system, there is a very important contribution in our method that the lower hardware complexity can be involved in the imaging system since many additive virtual array elements can be obtained. Numerical simulations are provided for testing our system and imaging method. PMID:20051345

  8. Calibration and characterization of spectral imaging systems

    NASA Astrophysics Data System (ADS)

    Polder, Gerrit; van der Heijden, Gerie W.

    2001-09-01

    Spectral image sensors provide images with a large umber of contiguous spectral channels per pixel. This paper describes the calibration of spectrograph based spectral imaging systems. The relation between pixel position and measured wavelength was determined using three different wavelength calibration sources. Results indicate that for spectral calibration a source with very small peaks,such as a HgAr source, is preferred to arrow band filters. A second order polynomial model gives a better fit than a linear model for the pixel to wavelength mapping. The signal to noise ratio (SNR)is determined per wavelength. In the blue part of the spectrum,the SNR was lower than in the green and red part.This is due to a decreased quantum efficiency of the CCD,a smaller transmission coefficient of the spectrograph,as well as poor performance of the illuminant. Increasing the amount of blue light,using additional Fluorescent tube with special coating increased the SNR considerably. Furthermore, the spatial and spectral resolution of the system are determined.These can be used to choose appropriate binning factors to decrease the image size without losing information.

  9. [Diagnostic imaging of central nervous system vasculitis].

    PubMed

    Yokota, Hajime; Yamada, Kei

    2015-03-01

    Vasculitis involving the central nervous system presents with infarction and hemorrhage, which are often nonspecific findings. Laboratory examinations are essential for diagnosis of vasculitis in addition to comprehensive and systematic review of the clinical course. Although most findings tend to be nonspecific, enhancement and thickening of the vascular wall indicate vasculitis. Visualization of the vascular wall requires selection of the appropriate imaging modality and mode of image acquisition. Contrast-enhanced CT, MRI, and FDG-PET are useful for visualizing large vessel vasculitis, while CT, MRI, and angiography are effective for medium vessel vasculitis. The use of ultrasound is limited to evaluating vessels on the body surface. Although relatively thick vessels can be demonstrated by angiography, complete survey of small vessels is difficult. Here, we summarize the characteristics of each imaging modality and imaging findings of typical vasculitides-Takayasu arteritis, giant cell arteritis, ANCA-associated vasculitis, Behçet's disease, primary angiitis of the CNS, and vasculitis associated with systemic disease. Differential diagnoses are also shown, including infective endocarditis, tuberculous meningitis, Ehlers-Danlos syndrome, and reversible cerebral vasoconstriction syndrome. PMID:25846439

  10. Digital imaging-based retinal photocoagulation system

    NASA Astrophysics Data System (ADS)

    Barrett, Steven F.; Wright, Cameron H. G.; Oberg, Erik D.; Rockwell, Benjamin A.; Cain, Clarence P.; Rylander, Henry G., III; Welch, Ashley J.

    1997-05-01

    Researchers at the USAF Academy and the University of Texas are developing a computer-assisted retinal photocoagulation system for the treatment of retinal disorders (i.e. diabetic retinopathy, retinal tears). Currently, ophthalmologists manually place therapeutic retinal lesions, an acquired technique that is tiring for both the patient and physician. The computer-assisted system under development can rapidly and safely place multiple therapeutic lesions at desired locations on the retina in a matter of seconds. Separate prototype subsystems have been developed to control lesion depth during irradiation and lesion placement to compensate for retinal movement. Both subsystems have been successfully demonstrated in vivo on pigmented rabbits using an argon continuous wave laser. Two different design approaches are being pursued to combine the capabilities of both subsystems: a digital imaging-based system and a hybrid analog-digital system. This paper will focus on progress with the digital imaging-based prototype system. A separate paper on the hybrid analog-digital system, `Hybrid Retinal Photocoagulation System', is also presented in this session.

  11. A knowledge-anchored integrative image search and retrieval system.

    PubMed

    Erdal, Selnur; Catalyurek, Umit V; Payne, Philip R O; Saltz, Joel; Kamal, Jyoti; Gurcan, Metin N

    2009-04-01

    Clinical data that may be used in a secondary capacity to support research activities are regularly stored in three significantly different formats: (1) structured, codified data elements; (2) semi-structured or unstructured narrative text; and (3) multi-modal images. In this manuscript, we will describe the design of a computational system that is intended to support the ontology-anchored query and integration of such data types from multiple source systems. Additional features of the described system include (1) the use of Grid services-based electronic data interchange models to enable the use of our system in multi-site settings and (2) the use of a software framework intended to address both potential security and patient confidentiality concerns that arise when transmitting or otherwise manipulating potentially privileged personal health information. We will frame our discussion within the specific experimental context of the concept-oriented query and integration of correlated structured data, narrative text, and images for cancer research.

  12. Properties of light reflected from road signs in active imaging.

    PubMed

    Halstuch, Aviran; Yitzhaky, Yitzhak

    2008-08-01

    Night vision systems in vehicles are a new emerging technology. A crucial problem in active (laser-based) systems is distortion of images by saturation and blooming due to strong retroreflections from road signs. We quantify this phenomenon. We measure the Mueller matrices and the polarization state of the reflected light from three different types of road sign commonly used. Measurements of the reflected intensity are also taken with respect to the angle of reflection. We find that different types of sign have different reflection properties. It is concluded that the optimal solution for attenuating the retroreflected intensity is using a linear polarized light source and a linear polarizer with perpendicular orientation (with regard to the source) at the detector. Unfortunately, while this solution performs well for two types of road sign, it is less efficient for the third sign type. PMID:18670559

  13. A LANDSAT digital image rectification system

    NASA Technical Reports Server (NTRS)

    Vanwie, P.; Stein, M.

    1976-01-01

    DIRS is a digital image rectification system for the geometric correction of LANDSAT multispectral scanner digital image data. DIRS removes spatial distortions from the data and brings it into conformance with the Universal Transverse Mercator (UTM) map projection. Scene data in the form of landmarks are used to drive the geometric correction algorithms. Two dimensional least squares polynominal and spacecraft attitude modeling techniques for geometric mapping are provided. Entire scenes or selected quadrilaterals may be rectified. Resampling through nearest neighbor or cubic convolution at user designated intervals is available. The output products are in the form of digital tape in band interleaved, single band or CCT format in a rotated UTM projection. The system was designed and implemented on large scale IBM 360 computers.

  14. The 94 GHz MMW imaging radar system

    NASA Technical Reports Server (NTRS)

    Alon, Yair; Ulmer, Lon

    1993-01-01

    The 94 GHz MMW airborne radar system that provides a runway image in adverse weather conditions is now undergoing tests at Wright-Patterson Air Force Base (WPAFB). This system, which consists of a solid state FMCW transceiver, antenna, and digital signal processor, has an update rate of 10 times per second, 0.35x azimuth resolution and up to 3.5 meter range resolution. The radar B scope (range versus azimuth) image, once converted to C scope (elevation versus azimuth), is compatible with the standard TV presentation and can be displayed on the Head Up Display (HUD) or Head Down Display (HDD) to aid the pilot during landing and takeoff in limited visibility conditions.

  15. Patient handling arrangements for NMR imaging systems

    SciTech Connect

    Carper, R.L.; Keller, J.T.

    1988-02-23

    In a nuclear magnetic resonance imaging system, including a magnet having a bore in which a subject to be imaged is to be located, a patient handling system is described comprising: a patient table which may be located so as to oppose the magnet bore, the patient table including a bottom portion and a top portion; a patient pallet, movably located on the top portion and adapted to be moved between the top portion and the magnet bore; mechanically driven transport means for transporting the patient pallet into and out of the magnet bore, including latch means for connecting the transport means to the patient pallet; and release means, located on the pallet, for manually releasing the latch means from the pallet, whereby the pallet may be manually removed from the magnet bore.

  16. Imaging the fetal central nervous system.

    PubMed

    De Keersmaecker, B; Claus, F; De Catte, L

    2011-01-01

    The low prevalence of fetal central nervous system anomalies results in a restricted level of exposure and limited experience-- for most of the obstetricians involved in prenatal ultrasound. Sonographic guidelines for screening the fetal brain in a systematic way will probably increase the detection rate and enhance a correct referral to a tertiary care center, offering the patient a multidisciplinary approach of the condition. This paper aims to elaborate on prenatal sonographic and magnetic resonance imaging (MRI) diagnosis and outcome of various central nervous system malformations. Detailed neurosonographic investigation has become available through high resolution vaginal ultrasound probes and the development of a variety of 3D ultrasound modalities e.g. ultrasound tomographic imaging. In addition, fetal MRI is particularly helpful in the detection of gyration and neurulation-- anomalies and disorders of the gray and white matter. PMID:24753859

  17. Requirements for imaging vulnerable plaque in the coronary artery using a coded aperture imaging system

    NASA Astrophysics Data System (ADS)

    Tozian, Cynthia

    A coded aperture1 plate was employed on a conventional gamma camera for 3D single photon emission computed tomography (SPECT) imaging on small animal models. The coded aperture design was selected to improve the spatial resolution and decrease the minimum detectable activity (MDA) required to image plaque formation in the APoE (apolipoprotein E) gene deficient mouse model when compared to conventional SPECT techniques. The pattern that was tested was a no-two-holes-touching (NTHT) modified uniformly redundant array (MURA) having 1,920 pinholes. The number of pinholes combined with the thin sintered tungsten plate was designed to increase the efficiency of the imaging modality over conventional gamma camera imaging methods while improving spatial resolution and reducing noise in the image reconstruction. The MDA required to image the vulnerable plaque in a human cardiac-torso mathematical phantom was simulated with a Monte Carlo code and evaluated to determine the optimum plate thickness by a receiver operating characteristic (ROC) yielding the lowest possible MDA and highest area under the curve (AUC). A partial 3D expectation maximization (EM) reconstruction was developed to improve signal-to-noise ratio (SNR), dynamic range, and spatial resolution over the linear correlation method of reconstruction. This improvement was evaluated by imaging a mini hot rod phantom, simulating the dynamic range, and by performing a bone scan of the C-57 control mouse. Results of the experimental and simulated data as well as other plate designs were analyzed for use as a small animal and potentially human cardiac imaging modality for a radiopharmaceutical developed at Bristol-Myers Squibb Medical Imaging Company, North Billerica, MA, for diagnosing vulnerable plaques. If left untreated, these plaques may rupture causing sudden, unexpected coronary occlusion and death. The results of this research indicated that imaging and reconstructing with this new partial 3D algorithm improved

  18. Image selection system. [computerized data storage and retrieval system

    NASA Technical Reports Server (NTRS)

    Knutson, M. A.; Hurd, D.; Hubble, L.; Kroeck, R. M.

    1974-01-01

    An image selection (ISS) was developed for the NASA-Ames Research Center Earth Resources Aircraft Project. The ISS is an interactive, graphics oriented, computer retrieval system for aerial imagery. An analysis of user coverage requests and retrieval strategies is presented, followed by a complete system description. Data base structure, retrieval processors, command language, interactive display options, file structures, and the system's capability to manage sets of selected imagery are described. A detailed example of an area coverage request is graphically presented.

  19. Active Volcano Monitoring using a Space-based Hyperspectral Imager

    NASA Astrophysics Data System (ADS)

    Cipar, J. J.; Dunn, R.; Cooley, T.

    2010-12-01

    Active volcanoes occur on every continent, often in close proximity to heavily populated areas. While ground-based studies are essential for scientific research and disaster mitigation, remote sensing from space can provide rapid and continuous monitoring of active and potentially active volcanoes [Ramsey and Flynn, 2004]. In this paper, we report on hyperspectral measurements of Kilauea volcano, Hawaii. Hyperspectral images obtained by the US Air Force TacSat-3/ARTEMIS sensor [Lockwood et al, 2006] are used to obtain estimates of the surface temperatures for the volcano. ARTEMIS measures surface-reflected light in the visible, near-infrared, and short-wave infrared bands (VNIR-SWIR). The SWIR bands are known to be sensitive to thermal radiation [Green, 1996]. For example, images from the NASA Hyperion hyperspectral sensor have shown the extent of wildfires and active volcanoes [Young, 2009]. We employ the methodology described by Dennison et al, (2006) to obtain an estimate of the temperature of the active region of Kilauea. Both day and night-time images were used in the analysis. To improve the estimate, we aggregated neighboring pixels. The active rim of the lava lake is clearly discernable in the temperature image, with a measured temperature exceeding 1100o C. The temperature decreases markedly on the exterior of the summit crater. While a long-wave infrared (LWIR) sensor would be ideal for volcano monitoring, we have shown that the thermal state of an active volcano can be monitored using the SWIR channels of a reflective hyperspectral imager. References: Dennison, Philip E., Kraivut Charoensiri, Dar A. Roberts, Seth H. Peterson, and Robert O. Green (2006). Wildfire temperature and land cover modeling using hyperspectral data, Remote Sens. Environ., vol. 100, pp. 212-222. Green, R. O. (1996). Estimation of biomass fire temperature and areal extent from calibrated AVIRIS spectra, in Summaries of the 6th Annual JPL Airborne Earth Science Workshop, Pasadena, CA

  20. Imaging system design for improved information capacity

    NASA Technical Reports Server (NTRS)

    Fales, C. L.; Huck, F. O.; Samms, R. W.

    1984-01-01

    Shannon's theory of information for communication channels is used to assess the performance of line-scan and sensor-array imaging systems and to optimize the design trade-offs involving sensitivity, spatial response, and sampling intervals. Formulations and computational evaluations account for spatial responses typical of line-scan and sensor-array mechanisms, lens diffraction and transmittance shading, defocus blur, and square and hexagonal sampling lattices.

  1. An Evolving System For Image Understanding

    NASA Astrophysics Data System (ADS)

    Bogdanowicz, Julius F.

    1985-07-01

    This paper presents an overview of efforts at Hughes sponsored by DARPA and ONR to demonstrate the application of research results from the DARPA Image Understanding Project. This effort has led to the development of a model based, predictive paradigm for image understanding, based on the ACRONYM system concept developed at Stanford University by Rod Brooks and Tom Binford. The completed initial system and a second system in development provide a capability for automated photo-interpretation by identifying instances of modeled objects in imagery. These implementations exercise elements of 3-D modeling, object feature prediction (including illumination and shadows), model directed feature extraction, and situation assessment via temporal analysis. The current system in development reflects the knowledge and experience gained in developing the initial system, where roadblocks to the development of the predictive vision paradigm were identified. A substantially new approach was taken in several areas and a new kernel of support tools was developed. The new system provides more robust performance and is built to support further extensions and testing.

  2. Automated method and system for the alignment and correlation of images from two different modalities

    DOEpatents

    Giger, Maryellen L.; Chen, Chin-Tu; Armato, Samuel; Doi, Kunio

    1999-10-26

    A method and system for the computerized registration of radionuclide images with radiographic images, including generating image data from radiographic and radionuclide images of the thorax. Techniques include contouring the lung regions in each type of chest image, scaling and registration of the contours based on location of lung apices, and superimposition after appropriate shifting of the images. Specific applications are given for the automated registration of radionuclide lungs scans with chest radiographs. The method in the example given yields a system that spatially registers and correlates digitized chest radiographs with V/Q scans in order to correlate V/Q functional information with the greater structural detail of chest radiographs. Final output could be the computer-determined contours from each type of image superimposed on any of the original images, or superimposition of the radionuclide image data, which contains high activity, onto the radiographic chest image.

  3. Whole-central nervous system functional imaging in larval Drosophila.

    PubMed

    Lemon, William C; Pulver, Stefan R; Höckendorf, Burkhard; McDole, Katie; Branson, Kristin; Freeman, Jeremy; Keller, Philipp J

    2015-08-11

    Understanding how the brain works in tight concert with the rest of the central nervous system (CNS) hinges upon knowledge of coordinated activity patterns across the whole CNS. We present a method for measuring activity in an entire, non-transparent CNS with high spatiotemporal resolution. We combine a light-sheet microscope capable of simultaneous multi-view imaging at volumetric speeds 25-fold faster than the state-of-the-art, a whole-CNS imaging assay for the isolated Drosophila larval CNS and a computational framework for analysing multi-view, whole-CNS calcium imaging data. We image both brain and ventral nerve cord, covering the entire CNS at 2 or 5 Hz with two- or one-photon excitation, respectively. By mapping network activity during fictive behaviours and quantitatively comparing high-resolution whole-CNS activity maps across individuals, we predict functional connections between CNS regions and reveal neurons in the brain that identify type and temporal state of motor programs executed in the ventral nerve cord.

  4. Whole-central nervous system functional imaging in larval Drosophila

    PubMed Central

    Lemon, William C.; Pulver, Stefan R.; Höckendorf, Burkhard; McDole, Katie; Branson, Kristin; Freeman, Jeremy; Keller, Philipp J.

    2015-01-01

    Understanding how the brain works in tight concert with the rest of the central nervous system (CNS) hinges upon knowledge of coordinated activity patterns across the whole CNS. We present a method for measuring activity in an entire, non-transparent CNS with high spatiotemporal resolution. We combine a light-sheet microscope capable of simultaneous multi-view imaging at volumetric speeds 25-fold faster than the state-of-the-art, a whole-CNS imaging assay for the isolated Drosophila larval CNS and a computational framework for analysing multi-view, whole-CNS calcium imaging data. We image both brain and ventral nerve cord, covering the entire CNS at 2 or 5 Hz with two- or one-photon excitation, respectively. By mapping network activity during fictive behaviours and quantitatively comparing high-resolution whole-CNS activity maps across individuals, we predict functional connections between CNS regions and reveal neurons in the brain that identify type and temporal state of motor programs executed in the ventral nerve cord. PMID:26263051

  5. An image stabilization system for solar observations

    NASA Astrophysics Data System (ADS)

    Sridharan, R.; Raja Bayanna, A.; Louis, Rohan Eugene; Kumar, Brajesh; Mathew, Shibu K.; Venkatakrishnan, P.

    2007-09-01

    An image stabilization system has been developed and demonstrated for solar observations in the visible wave-length at Udaipur Solar Observatory (USO) with a 15 cm Coudé-refractor. The softwa4re and hardware components of the system are similar to that of the low cost solar adaptive optics system developed for the 1.5 m McMath-Pierce solar telescope at Kitt Peak observatory for solar observations in the infrared. The first results presented. The system has a closed loop correction bandwidth in the range of 70 to 100 Hz. The root mean by a factor of 10 to 20. The software developes and key issues concerning optimum system performance have been addressed.

  6. Compact Microscope Imaging System with Intelligent Controls

    NASA Technical Reports Server (NTRS)

    McDowell, Mark

    2004-01-01

    The figure presents selected views of a compact microscope imaging system (CMIS) that includes a miniature video microscope, a Cartesian robot (a computer- controlled three-dimensional translation stage), and machine-vision and control subsystems. The CMIS was built from commercial off-the-shelf instrumentation, computer hardware and software, and custom machine-vision software. The machine-vision and control subsystems include adaptive neural networks that afford a measure of artificial intelligence. The CMIS can perform several automated tasks with accuracy and repeatability . tasks that, heretofore, have required the full attention of human technicians using relatively bulky conventional microscopes. In addition, the automation and control capabilities of the system inherently include a capability for remote control. Unlike human technicians, the CMIS is not at risk of becoming fatigued or distracted: theoretically, it can perform continuously at the level of the best human technicians. In its capabilities for remote control and for relieving human technicians of tedious routine tasks, the CMIS is expected to be especially useful in biomedical research, materials science, inspection of parts on industrial production lines, and space science. The CMIS can automatically focus on and scan a microscope sample, find areas of interest, record the resulting images, and analyze images from multiple samples simultaneously. Automatic focusing is an iterative process: The translation stage is used to move the microscope along its optical axis in a succession of coarse, medium, and fine steps. A fast Fourier transform (FFT) of the image is computed at each step, and the FFT is analyzed for its spatial-frequency content. The microscope position that results in the greatest dispersal of FFT content toward high spatial frequencies (indicating that the image shows the greatest amount of detail) is deemed to be the focal position.

  7. Small Interactive Image Processing System (SMIPS) system description

    NASA Technical Reports Server (NTRS)

    Moik, J. G.

    1973-01-01

    The Small Interactive Image Processing System (SMIPS) operates under control of the IBM-OS/MVT operating system and uses an IBM-2250 model 1 display unit as interactive graphic device. The input language in the form of character strings or attentions from keys and light pen is interpreted and causes processing of built-in image processing functions as well as execution of a variable number of application programs kept on a private disk file. A description of design considerations is given and characteristics, structure and logic flow of SMIPS are summarized. Data management and graphic programming techniques used for the interactive manipulation and display of digital pictures are also discussed.

  8. Being active after a heart attack (image)

    MedlinePlus

    ... best activity when you start exercising after a heart attack. Start slowly, and increase the amount of time ... best activity when you start exercising after a heart attack. Start slowly, and increase the amount of time ...

  9. Infrared Images of an Infant Solar System

    NASA Astrophysics Data System (ADS)

    2002-05-01

    ESO Telescopes Detect a Strange-Looking Object Summary Using the ESO 3.5-m New Technology Telescope and the Very Large Telescope (VLT) , a team of astronomers [1] have discovered a dusty and opaque disk surrounding a young solar-type star in the outskirts of a dark cloud in the Milky Way. It was found by chance during an unrelated research programme and provides a striking portrait of what our Solar System must have looked like when it was in its early infancy. Because of its striking appearance, the astronomers have nicknamed it the "Flying Saucer" . The new object appears to be a perfect example of a very young star with a disk in which planets are forming or will soon form, and located far away from the usual perils of an active star-forming environment . Most other young stars, especially those that are born in dense regions, run a serious risk of having their natal dusty disks destroyed by the blazing radiation of their more massive and hotter siblings in these clusters. The star at the centre of the "Flying Saucer", seems destined to live a long and quiet life at the centre of a planetary system , very much like our own Sun. This contributes to making it a most interesting object for further studies with the VLT and other telescopes. The mass of the observed disk of gas and dust is at least twice that of the planet Jupiter and its radius measures about 45 billion km, or 5 times the size of the orbit of Neptune. PR Photo 12a/02 : The "Flying Saucer" object photographed with NTT/SOFI. PR Photo 12b/02 : VLT/ISAAC image of this object. PR Photo 12c/02 : Enlargement of VLT/ISAAC image . Circumstellar Disks and Planets Planets form in dust disks around young stars. This is a complex process of which not all stages are yet fully understood but it begins when small dust particles collide and stick to each other. For this reason, observations of such dust disks, in particular those that appear as extended structures (are "resolved"), are very important for our

  10. FIZICS: fluorescent imaging zone identification system, a novel macro imaging system.

    PubMed

    Skwish, Stephen; Asensio, Francisco; King, Greg; Clarke, Glenn; Kath, Gary; Salvatore, Michael J; Dufresne, Claude

    2004-12-01

    Constantly improving biological assay development continues to drive technological requirements. Recently, a specification was defined for capturing white light and fluorescent images of agar plates ranging in size from the NUNC Omni tray (96-well footprint, 128 x 85 mm) to the NUNC Bio Assay Dish (245 x 245 mm). An evaluation of commercially available products failed to identify any system capable of fluorescent macroimaging with discrete wavelength selection. To address the lack of a commercially available system, a custom imaging system was designed and constructed. This system provides the same capabilities of many commercially available systems with the added ability to fluorescently image up to a 245 x 245 mm area using wavelengths in the visible light spectrum.

  11. High frequency active auroral research program (HAARP) imager

    NASA Astrophysics Data System (ADS)

    Lance, Cyril; Eather, Robert

    1993-09-01

    A low-light-level monochromatic imaging system was designed and fabricated which was optimized to detect and record optical emissions associated with high-power RF heating of the ionosphere. The instrument is capable of detecting very low intensities, of the order of 1 Rayleigh, from typical ionospheric atomic and molecular emissions. This is achieved through co-adding of ON images during heater pulses and subtraction of OFF (background) images between pulses. Images can be displayed and analyzed in real time and stored in optical disc for later analysis. Full image processing software is provided which was customized for this application and uses menu or mouse user interaction.

  12. Systems for increasing the sensitivity of gamma-ray imagers

    DOEpatents

    Mihailescu, Lucian; Vetter, Kai M.; Chivers, Daniel H.

    2012-12-11

    Systems that increase the position resolution and granularity of double sided segmented semiconductor detectors are provided. These systems increase the imaging resolution capability of such detectors, either used as Compton cameras, or as position sensitive radiation detectors in imagers such as SPECT, PET, coded apertures, multi-pinhole imagers, or other spatial or temporal modulated imagers.

  13. The Utility of Auroral Image-based Activities Metrics

    NASA Technical Reports Server (NTRS)

    Germany, G.; Spann, J.; Deverapalli, C.; Hung, C.-C.

    2004-01-01

    Auroral activity indices such as Hemispheric Power and Auroral Boundary are currently key data products used for space weather predictions and nowcasting. However, these products are necessarily based on limited observations which must be extrapolated to provide global coverage. The advent of routine space-based auroral imaging in the last decade offers the seeming advantage of more detailed measures of auroral activity. Examples of image-derived products include energy deposition maps, oval location, cap size, and morphological classification. However, activity metrics derived from auroral images have shortcomings, as well. For example, limited fields-of-view and orbital motion prevent full coverage of the auroral regions. This paper will examine the utility of activity metrics derived h m auroral images for operational purposes. The eight-year collection of Polar UVI images databased in the UVI Online Search Tool (OST) will be used to illustrate the advantages and shortcomings of auroral activity metrics. The potential role of other currently-active imaging missions will also be examined and correlative studies to date using auroral imaging will be summarized.

  14. In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system

    NASA Astrophysics Data System (ADS)

    Lv, Yanlu; Zhang, Jiulou; Zhang, Dong; Cai, Wenjuan; Chen, Nanguang; Luo, Jianwen

    2016-06-01

    A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in the scene. The implementation and performance of the simultaneous multispectral imaging system are presented. Further, the system's capability in simultaneously obtaining multispectral fluorescence measurements is demonstrated with in vivo experiments on a mouse. The demonstrated imaging system has the potential to obtain multispectral images fluorescence simultaneously.

  15. Eeg Imaging Of Brain Activity: Methods And Potentials

    NASA Astrophysics Data System (ADS)

    Coppola, Richard

    1984-08-01

    Currently there are several methods for creating images that relate to either the anatomy or function of the human brain. Static pictures of anatomical structures are produced by computerized axial tomography (CAT) and the presently evolving methods of nuclear magnetic resonance (NM P). These images give excellent resolution of various degrees of structures but do not reveal any aspects of function. A variety of radioactive labeling and detection techniques are available that produce images related to brain activity.

  16. Multimedia systems in ultrasound image boundary detection and measurements

    NASA Astrophysics Data System (ADS)

    Pathak, Sayan D.; Chalana, Vikram; Kim, Yongmin

    1997-05-01

    Ultrasound as a medical imaging modality offers the clinician a real-time of the anatomy of the internal organs/tissues, their movement, and flow noninvasively. One of the applications of ultrasound is to monitor fetal growth by measuring biparietal diameter (BPD) and head circumference (HC). We have been working on automatic detection of fetal head boundaries in ultrasound images. These detected boundaries are used to measure BPD and HC. The boundary detection algorithm is based on active contour models and takes 32 seconds on an external high-end workstation, SUN SparcStation 20/71. Our goal has been to make this tool available within an ultrasound machine and at the same time significantly improve its performance utilizing multimedia technology. With the advent of high- performance programmable digital signal processors (DSP), the software solution within an ultrasound machine instead of the traditional hardwired approach or requiring an external computer is now possible. We have integrated our boundary detection algorithm into a programmable ultrasound image processor (PUIP) that fits into a commercial ultrasound machine. The PUIP provides both the high computing power and flexibility needed to support computationally-intensive image processing algorithms within an ultrasound machine. According to our data analysis, BPD/HC measurements made on PUIP lie within the interobserver variability. Hence, the errors in the automated BPD/HC measurements using the algorithm are on the same order as the average interobserver differences. On PUIP, it takes 360 ms to measure the values of BPD/HC on one head image. When processing multiple head images in sequence, it takes 185 ms per image, thus enabling 5.4 BPD/HC measurements per second. Reduction in the overall execution time from 32 seconds to a fraction of a second and making this multimedia system available within an ultrasound machine will help this image processing algorithm and other computer-intensive imaging

  17. Active Response Gravity Offload System

    NASA Technical Reports Server (NTRS)

    Valle, Paul; Dungan, Larry; Cunningham, Thomas; Lieberman, Asher; Poncia, Dina

    2011-01-01

    The Active Response Gravity Offload System (ARGOS) provides the ability to simulate with one system the gravity effect of planets, moons, comets, asteroids, and microgravity, where the gravity is less than Earth fs gravity. The system works by providing a constant force offload through an overhead hoist system and horizontal motion through a rail and trolley system. The facility covers a 20 by 40-ft (approximately equals 6.1 by 12.2m) horizontal area with 15 ft (approximately equals4.6 m) of lifting vertical range.

  18. The moderate resolution imaging spectrometer data system

    NASA Technical Reports Server (NTRS)

    Han, Daesoo; Ardanuy, Philip E.

    1989-01-01

    Science requirements for a moderate resolution imaging spectrometer (MODIS) data system are outlined, as well as the operations concept and system specifications based on these requirements. Two systems are considered - MODIS-N for a 40-channel nadir-viewing scanner and MODIS-T for a 64-channel tiltable scanner. The first system collects data from 15 thermal-infrared channels at all times and from 25 reflected-energy channels during daytime, while MODIS-T will take data from 64 channels on a 100-percent duty cycle during daytime only. Standard data products, data acquisition and processing, and requirements on data are discussed. Emphasis is placed on the interfaces between the science data processing facilities and the scientific users.

  19. Circularly polarized antennas for active holographic imaging through barriers

    SciTech Connect

    McMakin, Douglas L; Severtsen, Ronald H; Lechelt, Wayne M; Prince, James M

    2011-07-26

    Circularly-polarized antennas and their methods of use for active holographic imaging through barriers. The antennas are dielectrically loaded to optimally match the dielectric constant of the barrier through which images are to be produced. The dielectric loading helps to remove barrier-front surface reflections and to couple electromagnetic energy into the barrier.

  20. Hyperspectral range imaging for transportation systems evaluation

    NASA Astrophysics Data System (ADS)

    Bridgelall, Raj; Rafert, J. B.; Atwood, Don; Tolliver, Denver D.

    2016-04-01

    Transportation agencies expend significant resources to inspect critical infrastructure such as roadways, railways, and pipelines. Regular inspections identify important defects and generate data to forecast maintenance needs. However, cost and practical limitations prevent the scaling of current inspection methods beyond relatively small portions of the network. Consequently, existing approaches fail to discover many high-risk defect formations. Remote sensing techniques offer the potential for more rapid and extensive non-destructive evaluations of the multimodal transportation infrastructure. However, optical occlusions and limitations in the spatial resolution of typical airborne and space-borne platforms limit their applicability. This research proposes hyperspectral image classification to isolate transportation infrastructure targets for high-resolution photogrammetric analysis. A plenoptic swarm of unmanned aircraft systems will capture images with centimeter-scale spatial resolution, large swaths, and polarization diversity. The light field solution will incorporate structure-from-motion techniques to reconstruct three-dimensional details of the isolated targets from sequences of two-dimensional images. A comparative analysis of existing low-power wireless communications standards suggests an application dependent tradeoff in selecting the best-suited link to coordinate swarming operations. This study further produced a taxonomy of specific roadway and railway defects, distress symptoms, and other anomalies that the proposed plenoptic swarm sensing system would identify and characterize to estimate risk levels.

  1. A high frequency electromagnetic impedance imaging system

    SciTech Connect

    Tseng, Hung-Wen; Lee, Ki Ha; Becker, Alex

    2003-01-15

    Non-invasive, high resolution geophysical mapping of the shallow subsurface is necessary for delineation of buried hazardous wastes, detecting unexploded ordinance, verifying and monitoring of containment or moisture contents, and other environmental applications. Electromagnetic (EM) techniques can be used for this purpose since electrical conductivity and dielectric permittivity are representative of the subsurface media. Measurements in the EM frequency band between 1 and 100 MHz are very important for such applications, because the induction number of many targets is small and the ability to determine the subsurface distribution of both electrical properties is required. Earlier workers were successful in developing systems for detecting anomalous areas, but quantitative interpretation of the data was difficult. Accurate measurements are necessary, but difficult to achieve for high-resolution imaging of the subsurface. We are developing a broadband non-invasive method for accurately mapping the electrical conductivity and dielectric permittivity of the shallow subsurface using an EM impedance approach similar to the MT exploration technique. Electric and magnetic sensors were tested to ensure that stray EM scattering is minimized and the quality of the data collected with the high-frequency impedance (HFI) system is good enough to allow high-resolution, multi-dimensional imaging of hidden targets. Additional efforts are being made to modify and further develop existing sensors and transmitters to improve the imaging capability and data acquisition efficiency.

  2. Imaging tree root systems in situ

    NASA Astrophysics Data System (ADS)

    Wielopolski, Lucian; Hendrey, George; Daniels, Jeffrey J.; McGuigan, Michael

    2000-04-01

    Predictions of global energy use in this century suggest a continued increase in carbon emissions and rising concentrations of carbon dioxide (CO2) in the atmosphere. This represents a serious environmental problem and contributes significantly to greenhouse gases that affect global warming. Terrestrial ecosystems are a huge natural biological scrubber for CO2 currently sequestering, directly from the atmosphere, about 25% (approximately 2 GtC) of the 7.4 Gt of anthropogenic carbon emitted annually into the atmosphere. The major carbon pathways into soil are through plant litter and roots. Presently, there are no means by which root morphology, distribution, and mass can be measured without serious sampling artifacts that alter these properties. The current methods are destructive and labor intensive. Preliminary results using a high frequency, 1.5 Ghz, impulse Ground Penetrating Radar (GPR) for nondestructive imaging of tree root systems in situ are presented. The 3D reconstructed image is used to assess root morphology and dimensions. The constraints, limitations, and potential solutions for using GPR for tree root systems imaging and analysis are discussed.

  3. Multiple classifier system for remote sensing image classification: a review.

    PubMed

    Du, Peijun; Xia, Junshi; Zhang, Wei; Tan, Kun; Liu, Yi; Liu, Sicong

    2012-01-01

    Over the last two decades, multiple classifier system (MCS) or classifier ensemble has shown great potential to improve the accuracy and reliability of remote sensing image classification. Although there are lots of literatures covering the MCS approaches, there is a lack of a comprehensive literature review which presents an overall architecture of the basic principles and trends behind the design of remote sensing classifier ensemble. Therefore, in order to give a reference point for MCS approaches, this paper attempts to explicitly review the remote sensing implementations of MCS and proposes some modified approaches. The effectiveness of existing and improved algorithms are analyzed and evaluated by multi-source remotely sensed images, including high spatial resolution image (QuickBird), hyperspectral image (OMISII) and multi-spectral image (Landsat ETM+). Experimental results demonstrate that MCS can effectively improve the accuracy and stability of remote sensing image classification, and diversity measures play an active role for the combination of multiple classifiers. Furthermore, this survey provides a roadmap to guide future research, algorithm enhancement and facilitate knowledge accumulation of MCS in remote sensing community.

  4. Multiple Classifier System for Remote Sensing Image Classification: A Review

    PubMed Central

    Du, Peijun; Xia, Junshi; Zhang, Wei; Tan, Kun; Liu, Yi; Liu, Sicong

    2012-01-01

    Over the last two decades, multiple classifier system (MCS) or classifier ensemble has shown great potential to improve the accuracy and reliability of remote sensing image classification. Although there are lots of literatures covering the MCS approaches, there is a lack of a comprehensive literature review which presents an overall architecture of the basic principles and trends behind the design of remote sensing classifier ensemble. Therefore, in order to give a reference point for MCS approaches, this paper attempts to explicitly review the remote sensing implementations of MCS and proposes some modified approaches. The effectiveness of existing and improved algorithms are analyzed and evaluated by multi-source remotely sensed images, including high spatial resolution image (QuickBird), hyperspectral image (OMISII) and multi-spectral image (Landsat ETM+). Experimental results demonstrate that MCS can effectively improve the accuracy and stability of remote sensing image classification, and diversity measures play an active role for the combination of multiple classifiers. Furthermore, this survey provides a roadmap to guide future research, algorithm enhancement and facilitate knowledge accumulation of MCS in remote sensing community. PMID:22666057

  5. MCT SWIR modules for passive and active imaging applications

    NASA Astrophysics Data System (ADS)

    Breiter, R.; Benecke, M.; Eich, D.; Figgemeier, H.; Weber, A.; Wendler, J.; Sieck, A.

    2016-05-01

    Based on AIM's state-of-the-art MCT IR technology, detector modules for the SWIR spectral range have been developed, fabricated and characterized. While LPE grown MCT FPAs with extended 2.5μm cut-off have been fabricated and integrated also MBE grown MCT on GaAs is considered for future production. Two imaging applications have been in focus operating either in passive mode by making use of e.g. the night glow, or in active mode by laser illumination for gated viewing. Dedicated readout integrated circuits (ROIC), realized in 0.18μm Si-CMOS technology providing the required functionality for passive imaging and gated imaging, have been designed and implemented. For both designs a 640x512 15μm pitch format was chosen. The FPAs are integrated in compact dewar cooler configurations using AIM's split linear coolers. A command and control electronics (CCE) provides supply voltages, biasing, clocks, control and video digitization for easy system interfacing. For imaging under low-light conditions a low-noise 640x512 15μm pitch ROIC with CTIA input stages and correlated double sampling was designed. The ROIC provides rolling shutter and snapshot integration. To reduce size, weight, power and cost (SWaP-C) a 640x512 format detector in a 10μm pitch is under development. The module makes use of the extended SWIR spectral cut-off up to 2.5μm. To be used for active gated-viewing operation SWIR MCT avalanche photodiodes have been implemented and characterized on FPA level in a 640x512 15μm pitch format. The specific ROIC provides also the necessary functions for range gate control and triggering by the laser illumination. First lab and field tests of a gated viewing demonstrator have been carried out. The paper will present the development status and performance results of AIM's MCT based SWIR Modules for imaging applications.

  6. Using Digital Imaging in Classroom and Outdoor Activities.

    ERIC Educational Resources Information Center

    Thomasson, Joseph R.

    2002-01-01

    Explains how to use digital cameras and related basic equipment during indoor and outdoor activities. Uses digital imaging in general botany class to identify unknown fungus samples. Explains how to select a digital camera and other necessary equipment. (YDS)

  7. Calcium Imaging of Neuronal Activity in Free-Swimming Larval Zebrafish.

    PubMed

    Muto, Akira; Kawakami, Koichi

    2016-01-01

    Visualization of neuronal activity during animal behavior is a critical step in understanding how the brain generates behavior. In the model vertebrate zebrafish, imaging of the brain has been done mostly by using immobilized fish. Here, we describe a novel method to image neuronal activity of the larval zebrafish brain during prey capture behavior. We expressed a genetically encoded fluorescent calcium indicator, GCaMP, in the optic tectum of the midbrain using the Gal4-UAS system. Tectal activity was then imaged in unrestrained larvae during prey perception. Since larval zebrafish swim only intermittently, detection of the neuronal activity is possible between swimming bouts. Our method makes functional brain imaging under natural behavioral conditions feasible and will greatly benefit the study of neuronal activities that evoke animal behaviors. PMID:27464819

  8. An integral design strategy combining optical system and image processing to obtain high resolution images

    NASA Astrophysics Data System (ADS)

    Wang, Jiaoyang; Wang, Lin; Yang, Ying; Gong, Rui; Shao, Xiaopeng; Liang, Chao; Xu, Jun

    2016-05-01

    In this paper, an integral design that combines optical system with image processing is introduced to obtain high resolution images, and the performance is evaluated and demonstrated. Traditional imaging methods often separate the two technical procedures of optical system design and imaging processing, resulting in the failures in efficient cooperation between the optical and digital elements. Therefore, an innovative approach is presented to combine the merit function during optical design together with the constraint conditions of image processing algorithms. Specifically, an optical imaging system with low resolution is designed to collect the image signals which are indispensable for imaging processing, while the ultimate goal is to obtain high resolution images from the final system. In order to optimize the global performance, the optimization function of ZEMAX software is utilized and the number of optimization cycles is controlled. Then Wiener filter algorithm is adopted to process the image simulation and mean squared error (MSE) is taken as evaluation criterion. The results show that, although the optical figures of merit for the optical imaging systems is not the best, it can provide image signals that are more suitable for image processing. In conclusion. The integral design of optical system and image processing can search out the overall optimal solution which is missed by the traditional design methods. Especially, when designing some complex optical system, this integral design strategy has obvious advantages to simplify structure and reduce cost, as well as to gain high resolution images simultaneously, which has a promising perspective of industrial application.

  9. Molecular Imaging of the ATM Kinase Activity

    SciTech Connect

    Williams, Terence M.; Nyati, Shyam; Ross, Brian D.; Rehemtulla, Alnawaz

    2013-08-01

    Purpose: Ataxia telangiectasia mutated (ATM) is a serine/threonine kinase critical to the cellular DNA-damage response, including from DNA double-strand breaks. ATM activation results in the initiation of a complex cascade of events including DNA damage repair, cell cycle checkpoint control, and survival. We sought to create a bioluminescent reporter that dynamically and noninvasively measures ATM kinase activity in living cells and subjects. Methods and Materials: Using the split luciferase technology, we constructed a hybrid cDNA, ATM-reporter (ATMR), coding for a protein that quantitatively reports on changes in ATM kinase activity through changes in bioluminescence. Results: Treatment of ATMR-expressing cells with ATM inhibitors resulted in a dose-dependent increase in bioluminescence activity. In contrast, induction of ATM kinase activity upon irradiation resulted in a decrease in reporter activity that correlated with ATM and Chk2 activation by immunoblotting in a time-dependent fashion. Nuclear targeting improved ATMR sensitivity to both ATM inhibitors and radiation, whereas a mutant ATMR (lacking the target phosphorylation site) displayed a muted response. Treatment with ATM inhibitors and small interfering (si)RNA-targeted knockdown of ATM confirm the specificity of the reporter. Using reporter expressing xenografted tumors demonstrated the ability of ATMR to report in ATM activity in mouse models that correlated in a time-dependent fashion with changes in Chk2 activity. Conclusions: We describe the development and validation of a novel, specific, noninvasive bioluminescent reporter that enables monitoring of ATM activity in real time, in vitro and in vivo. Potential applications of this reporter include the identification and development of novel ATM inhibitors or ATM-interacting partners through high-throughput screens and in vivo pharmacokinetic/pharmacodynamic studies of ATM inhibitors in preclinical models.

  10. Design and implementation of semantics-based image retrieval system

    NASA Astrophysics Data System (ADS)

    Ni, Chundi; Liu, Shenkui; Pan, Ligong; Yin, Xiaowei

    2015-07-01

    Through the study of the existing image retrieval technology, in this paper, a new design scheme of semantics-based image retrieval system is presented. Based on the establishment of mapping relationship between the low-level image features and the low layer of semantic image, this scheme associates the low layer of semantic image with high-level semantics, thus realizing hierarchical semantics description structure, to improve the high-level semantic image recognition accuracy rate.

  11. Intelligent elevator management system using image processing

    NASA Astrophysics Data System (ADS)

    Narayanan, H. Sai; Karunamurthy, Vignesh; Kumar, R. Barath

    2015-03-01

    In the modern era, the increase in the number of shopping malls and industrial building has led to an exponential increase in the usage of elevator systems. Thus there is an increased need for an effective control system to manage the elevator system. This paper is aimed at introducing an effective method to control the movement of the elevators by considering various cases where in the location of the person is found and the elevators are controlled based on various conditions like Load, proximity etc... This method continuously monitors the weight limit of each elevator while also making use of image processing to determine the number of persons waiting for an elevator in respective floors. Canny edge detection technique is used to find out the number of persons waiting for an elevator. Hence the algorithm takes a lot of cases into account and locates the correct elevator to service the respective persons waiting in different floors.

  12. Integrated bio-inspired fluidic imaging system

    NASA Astrophysics Data System (ADS)

    Tsai, Frank S.; Johnson, Daniel; Cho, Sung Hwan; Qiao, Wen; Arianpour, Ashkan; Francis, Cameron S.; Kim, Nam-Hyong; Lo, Yu-Hwa

    2010-02-01

    We developed a new type of optical lens device that can change its curvature like crystalline lens in human eye. The curvature changing capability of the lens allows for a tremendous tuning range in its optical power and subsequently enables miniaturized imaging systems that can perform autofocus, optical zoom, and other advanced functions. In this paper, we study the physical properties of bio-inspired fluidic lenses and demonstrate the optical functionality through miniaturized optical systems constructed with such lenses. We report an auto-focusing optical system that can turn from a camera to a microscope, and demonstrate more than 4X optical zoom with a very short total track length. Finally, we demonstrate the benefits of fluidic lens zoom camera through minimally invasive gallbladder removal surgery.

  13. Active Learning in Context-Driven Stream Mining With an Application to Image Mining.

    PubMed

    Tekin, Cem; van der Schaar, Mihaela

    2015-11-01

    We propose an image stream mining method in which images arrive with contexts (metadata) and need to be processed in real time by the image mining system (IMS), which needs to make predictions and derive actionable intelligence from these streams. After extracting the features of the image by preprocessing, IMS determines online the classifier to use on the extracted features to make a prediction using the context of the image. A key challenge associated with stream mining is that the prediction accuracy of the classifiers is unknown, since the image source is unknown; thus, these accuracies need to be learned online. Another key challenge of stream mining is that learning can only be done by observing the true label, but this is costly to obtain. To address these challenges, we model the image stream mining problem as an active, online contextual experts problem, where the context of the image is used to guide the classifier selection decision. We develop an active learning algorithm and show that it achieves regret sublinear in the number of images that have been observed so far. To further illustrate and assess the performance of our proposed methods, we apply them to diagnose breast cancer from the images of cellular samples obtained from the fine needle aspirate of breast mass. Our findings show that very high diagnosis accuracy can be achieved by actively obtaining only a small fraction of true labels through surgical biopsies. Other applications include video surveillance and video traffic monitoring. PMID:26087490

  14. Architecture For An Image Filing And Indexing System

    NASA Astrophysics Data System (ADS)

    Hack, Stanley N.; Paoni, Robert A.; Robeson, Glenn H.

    1986-06-01

    We are developing an in-house Picture Archiving and Communication System (PACS) targeted to the centralized storage of images acquired from our computer-assisted imaging modalities and to the display of these images on multi-modality viewing stations. The central image database is distributed between two system modules with image processing capabilities located at the viewing stations. The first module of the image database is an image filing subsystem used for the storage and retrieval of complete image files. In our initial work, this module consists of a Data General MV/6000 computer system with 1.16 Gbytes of on-line disk storage. However, more efficient dedicated filing systems may be substituted for this general purpose computer in future revisions. The second module is an image file indexing subsystem which has been implemented on a DEC PDP-11/44 computer and is tightly integrated with our MARS II (ADAC Laboratories) Radiology Information System. These two image database modules communicate via low-speed, serial communications lines. This report focuses on our developmental work on the image file indexing subsystem and its communications protocol with the image filing subsystem. The image file indexing subsystem automatically inserts image file locators for studies referenced by patient when an image is transmitted from the acquisition device (eg, CT) to the image filing subsystem. It also locates image files at the request of a viewing station user based on patient name, physician name, or study type for either read or unread studies. Other capabilities include cross-referencing patient attributes with the MARS II system, deleting studies based on predefined criteria, storing requests for hard copy, storing user selected image processing attributes for individual images, flagging the archival status of an image, and complete managerial functions. This central-ized image filing and indexing system comprises what will become the central element of our PACS.

  15. Compact wearable dual-mode imaging system for real-time fluorescence image-guided surgery

    NASA Astrophysics Data System (ADS)

    Zhu, Nan; Huang, Chih-Yu; Mondal, Suman; Gao, Shengkui; Huang, Chongyuan; Gruev, Viktor; Achilefu, Samuel; Liang, Rongguang

    2015-09-01

    A wearable all-plastic imaging system for real-time fluorescence image-guided surgery is presented. The compact size of the system is especially suitable for applications in the operating room. The system consists of a dual-mode imaging system, see-through goggle, autofocusing, and auto-contrast tuning modules. The paper will discuss the system design and demonstrate the system performance.

  16. Compact wearable dual-mode imaging system for real-time fluorescence image-guided surgery

    PubMed Central

    Zhu, Nan; Huang, Chih-Yu; Mondal, Suman; Gao, Shengkui; Huang, Chongyuan; Gruev, Viktor; Achilefu, Samuel; Liang, Rongguang

    2015-01-01

    Abstract. A wearable all-plastic imaging system for real-time fluorescence image-guided surgery is presented. The compact size of the system is especially suitable for applications in the operating room. The system consists of a dual-mode imaging system, see-through goggle, autofocusing, and auto-contrast tuning modules. The paper will discuss the system design and demonstrate the system performance. PMID:26358823

  17. 21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1560 Ultrasonic pulsed echo imaging system. (a) Identification. An ultrasonic pulsed echo imaging system is a device intended to project a... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ultrasonic pulsed echo imaging system....

  18. 21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1560 Ultrasonic pulsed echo imaging system. (a) Identification. An ultrasonic pulsed echo imaging system is a device intended to project a... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic pulsed echo imaging system....

  19. 21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed echo imaging system. 892.1560... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1560 Ultrasonic pulsed echo imaging system. (a) Identification. An ultrasonic pulsed echo imaging system is a device intended to project...

  20. Near-infrared compressive line sensing imaging system using individually addressable laser diode array

    NASA Astrophysics Data System (ADS)

    Ouyang, Bing; Hou, Weilin; Caimi, Frank M.; Dalgleish, Fraser R.; Vuorenkoski, Anni K.; Gong, Sue; Britton, Walter

    2015-05-01

    The compressive line sensing (CLS) active imaging system was proposed and validated through a series of test-tank experiments. As an energy-efficient alternative to the traditional line-scan serial image, the CLS system will be highly beneficial for long-duration surveillance missions using unmanned, power-constrained platforms such as unmanned aerial or underwater vehicles. In this paper, the application of an active spatial light modulator (SLM), the individually addressable laser diode array, in a CLS imaging system is investigated. In the CLS context, active SLM technology can be advantageous over passive SLMs such as the digital micro-mirror device. Initial experimental results are discussed.

  1. Imaging of alkaline phosphatase activity in bone tissue.

    PubMed

    Gade, Terence P; Motley, Matthew W; Beattie, Bradley J; Bhakta, Roshni; Boskey, Adele L; Koutcher, Jason A; Mayer-Kuckuk, Philipp

    2011-01-01

    The purpose of this study was to develop a paradigm for quantitative molecular imaging of bone cell activity. We hypothesized the feasibility of non-invasive imaging of the osteoblast enzyme alkaline phosphatase (ALP) using a small imaging molecule in combination with (19)Flourine magnetic resonance spectroscopic imaging ((19)FMRSI). 6, 8-difluoro-4-methylumbelliferyl phosphate (DiFMUP), a fluorinated ALP substrate that is activatable to a fluorescent hydrolysis product was utilized as a prototype small imaging molecule. The molecular structure of DiFMUP includes two Fluorine atoms adjacent to a phosphate group allowing it and its hydrolysis product to be distinguished using (19)Fluorine magnetic resonance spectroscopy ((19)FMRS) and (19)FMRSI. ALP-mediated hydrolysis of DiFMUP was tested on osteoblastic cells and bone tissue, using serial measurements of fluorescence activity. Extracellular activation of DiFMUP on ALP-positive mouse bone precursor cells was observed. Concurringly, DiFMUP was also activated on bone derived from rat tibia. Marked inhibition of the cell and tissue activation of DiFMUP was detected after the addition of the ALP inhibitor levamisole. (19)FMRS and (19)FMRSI were applied for the non-invasive measurement of DiFMUP hydrolysis. (19)FMRS revealed a two-peak spectrum representing DiFMUP with an associated chemical shift for the hydrolysis product. Activation of DiFMUP by ALP yielded a characteristic pharmacokinetic profile, which was quantifiable using non-localized (19)FMRS and enabled the development of a pharmacokinetic model of ALP activity. Application of (19)FMRSI facilitated anatomically accurate, non-invasive imaging of ALP concentration and activity in rat bone. Thus, (19)FMRSI represents a promising approach for the quantitative imaging of bone cell activity during bone formation with potential for both preclinical and clinical applications. PMID:21799916

  2. Planet signatures in collisionally active debris discs: scattered light images

    NASA Astrophysics Data System (ADS)

    Thebault, P.; Kral, Q.; Ertel, S.

    2012-11-01

    Context. Planet perturbations have been often invoked as a potential explanation for many spatial structures that have been imaged in debris discs. So far this issue has been mostly investigated with pure N-body numerical models, which neglect the crucial effect collisions within the disc can have on the disc's response to dynamical perturbations. Aims: We numerically investigate how the coupled effect of collisions and radiation pressure can affect the formation and survival of radial and azimutal structures in a disc perturbed by a planet. We consider two different set-ups: a planet embedded within an extended disc and a planet exterior to an inner debris ring. One important issue we want to address is under which conditions a planet's signature can be observable in a collisionally active disc. Methods: We use our DyCoSS code, which is designed to investigate the structure of perturbed debris discs at dynamical and collisional steady-state, and derive synthetic images of the system in scattered light. The planet's mass and orbit, as well as the disc's collisional activity (parameterized by its average vertical optical depth τ0) are explored as free parameters. Results: We find that collisions always significantly damp planet-induced spatial structures. For the case of an embedded planet, the planet's signature, mostly a density gap around its radial position, should remain detectable in head-on images if Mplanet ≥ MSaturn. If the system is seen edge-on, however, inferring the presence of the planet is much more difficult, as only weak asymmetries remain in a collisionally active disc, although some planet-induced signatures might be observable under very favourable conditions. For the case of an inner ring and an external planet, planetary perturbations cannot prevent collision-produced small fragments from populating the regions beyond the ring. The radial luminosity profile exterior to the ring is in most cases close to the one it should have in the absence

  3. Towards brain-activity-controlled information retrieval: Decoding image relevance from MEG signals.

    PubMed

    Kauppi, Jukka-Pekka; Kandemir, Melih; Saarinen, Veli-Matti; Hirvenkari, Lotta; Parkkonen, Lauri; Klami, Arto; Hari, Riitta; Kaski, Samuel

    2015-05-15

    We hypothesize that brain activity can be used to control future information retrieval systems. To this end, we conducted a feasibility study on predicting the relevance of visual objects from brain activity. We analyze both magnetoencephalographic (MEG) and gaze signals from nine subjects who were viewing image collages, a subset of which was relevant to a predetermined task. We report three findings: i) the relevance of an image a subject looks at can be decoded from MEG signals with performance significantly better than chance, ii) fusion of gaze-based and MEG-based classifiers significantly improves the prediction performance compared to using either signal alone, and iii) non-linear classification of the MEG signals using Gaussian process classifiers outperforms linear classification. These findings break new ground for building brain-activity-based interactive image retrieval systems, as well as for systems utilizing feedback both from brain activity and eye movements.

  4. Augmented reality based real-time subcutaneous vein imaging system.

    PubMed

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed. PMID:27446690

  5. Augmented reality based real-time subcutaneous vein imaging system.

    PubMed

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  6. Augmented reality based real-time subcutaneous vein imaging system

    PubMed Central

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-01-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed. PMID:27446690

  7. A Landsat Digital Image Rectification System

    NASA Technical Reports Server (NTRS)

    Van Wie, P.; Stein, M.

    1976-01-01

    DIRS is a Digital Image Rectification System for the geometric correction of Landsat Multispectral Scanner digital image data. DIRS removes spatial distortions from the data and brings it into conformance with the Universal Transverse Mercator (UTM) map projection. Scene data in the form of landmarks or Ground Control Points (GCPs) are used to drive the geometric correction algorithms. The system offers extensive capabilities for 'shade printing' to aid in the determination of GCPs. Affine, two dimensional least squares polynominal and spacecraft attitude modeling techniques for geometric mapping are provided. Entire scenes or selected quadralaterals may be rectified. Resampling through nearest neighbor or cubic convolution at user designated intervals is available. The output products are in the form of digital tape in band interleaved, single band or CCT format in a rotated UTM projection. The system was designed and implemented on large scale IBM 360 computers with at least 300-500K bytes of memory for user application programs and five nine track tapes plus direct access storage.

  8. Image-gathering system design for information and fidelity

    NASA Technical Reports Server (NTRS)

    Huck, Friedrich O.; Fales, Carl L.; Mccormick, Judith A.; Park, Stephen K.

    1988-01-01

    Image gathering and processing are assessed in terms of information and fidelity, and the relationship between these two figures of merit is examined. It is assumed that the system is linear and isoplanatic and that the signal and noise amplitudes are Gaussian, wide-sense stationary, and statistically independent. Within these constraints, it is found that the combined process of image gathering and reconstruction (which is intended to reproduce the output of the image-gathering system) behaves as optical, or photographic, image formation in that the informationally optimized design of the image-gathering system ordinarily does not maximize the fidelity of the reconstructed image. The combined process of image gathering and restoration (which is intended to reproduce the input of the image-gathering system) behaves more as a communication channel in that the informationally optimized design of the image-gathering system tends to maximize the fidelity of optimally restored representations of the input.

  9. Multispectral imaging system for contaminant detection

    NASA Technical Reports Server (NTRS)

    Poole, Gavin H. (Inventor)

    2003-01-01

    An automated inspection system for detecting digestive contaminants on food items as they are being processed for consumption includes a conveyor for transporting the food items, a light sealed enclosure which surrounds a portion of the conveyor, with a light source and a multispectral or hyperspectral digital imaging camera disposed within the enclosure. Operation of the conveyor, light source and camera are controlled by a central computer unit. Light reflected by the food items within the enclosure is detected in predetermined wavelength bands, and detected intensity values are analyzed to detect the presence of digestive contamination.

  10. Dedicated IR imaging fire sensor systems

    NASA Astrophysics Data System (ADS)

    Roeser, Hans-Peter; Jahn, Herbert; Briess, Klaus; Lorenz, Eckehard; Skrbek, Wolfgang; Walter, Ingo; Oertel, Dieter

    2000-07-01

    The German Aerospace Center (DLR) and its industrial partners are working on two new spaceborne fire missions: (1) the Bi-spectral IR Detection small satellite mission (BIRD) to be launched in autumn 2000, and (2) the Innovative Infrared Sensor System FOCUS to be flown as an early external payload of the International Space Station. Both BIRD and FOCUS will use MIR/TIR solid state pushbroom imagers with real time digital signal processing providing an adaptive and very high dynamic range in radiometry. Promising results are obtained with the BIRD Airborne Simulator which has been flown at DLR in several airborne campaigns since 1997.

  11. THz imaging system with the IJJ emitter

    NASA Astrophysics Data System (ADS)

    Tsujimoto, Manabu; Minami, Hidetoshi; Sawamura, Masashi; Delfanazari, Kaveh; Yamamoto, Takashi; Kashiwagi, Takanari; Kadowaki, Kazuo

    2011-03-01

    The intrinsic Josephson junction (IJJ) emitter consisted of thousands of IJJs uniformly stacked in single crystalline high-Tc superconductor Bi 2 Sr 2 CaCu 2 O8 + δ (Bi-2212) [L. Ozyuzer et al., Science 318, (2007) 1291.] is expected to be a novel source of the continuous terahertz electromagnetic waves (THz-waves). The maximum emission power of tens of microwatts recently obtained with the mesa structure of IJJs seems to be sufficient to make use of the IJJ emitter for some practical applications such as THz imaging. According to the cavity resonance condition, we can control the radiation frequency by changing the geometrical size of the mesa. In this study, we develop the THz imaging system with IJJ emitter. In the presentation, we will show some transparent images of standard specimens obtained by the raster scanning method. Also, we will mention some problems to be solved for the future applications of the IJJ emitter. CREST-JST, WPI-MANA, Strategic Initiative A (University of Tsukuba).

  12. Direct method of three-dimensional imaging using the multiple-wavelength range-gated active imaging principle.

    PubMed

    Matwyschuk, Alexis

    2016-05-10

    The tomography executed with mono-wavelength active imaging systems uses the recording of several images to restore a three-dimensional (3D) scene. Thus, in order to show the depth in the scene, a different color is attributed to each recorded image. Therefore, the 3D restoration depends on the video frame rate of the camera. By using a multiple-wavelength range-gated active imaging system, it is possible to restore the 3D scene directly in a single image at the moment of recording with a video camera. Each emitted light pulse with a different wavelength corresponds to a visualized zone at a different distance in the scene. The camera shutter opens just once during the emission of light pulses with the different wavelengths. Thus, the restoration can be executed in real time with regard to the video frame rate of the camera. From an analytical model and from a graphical approach, we demonstrated the feasibility of this new method of 3D restoration. The non-overlapping conditions between two consecutive visualized zones are analyzed. The experimental test results confirm these different conditions and validate the theoretical principle to directly restore the 3D scene in a color image with a multiple-wavelength laser source, an RGB filter, and a triggerable intensified camera. PMID:27168293

  13. Three-dimensional integral imaging display system via off-axially distributed image sensing

    NASA Astrophysics Data System (ADS)

    Piao, Yongri; Qu, Hongjia; Zhang, Miao; Cho, Myungjin

    2016-10-01

    In this paper, we propose a three-dimensional integral imaging display system with a multiple recorded images using off-axially distributed image sensing. First, the depth map of the 3D objects is extracted from the off-axially recorded multi-perspective 2D images by using profilometry technique. Then, the elemental image array is computationally synthesized using the extracted depth map based on ray mapping model. Finally, the 3D images are optically displayed in integral imaging system. To show the feasibility of the proposed method, the optical experiments for 3D objects are carried out and presented in this paper.

  14. NIR DLP hyperspectral imaging system for medical applications

    NASA Astrophysics Data System (ADS)

    Wehner, Eleanor; Thapa, Abhas; Livingston, Edward; Zuzak, Karel

    2011-03-01

    DLP® hyperspectral reflectance imaging in the visible range has been previously shown to quantify hemoglobin oxygenation in subsurface tissues, 1 mm to 2 mm deep. Extending the spectral range into the near infrared reflects biochemical information from deeper subsurface tissues. Unlike any other illumination method, the digital micro-mirror device, DMD, chip is programmable, allowing the user to actively illuminate with precisely predetermined spectra of illumination with a minimum bandpass of approximately 10 nm. It is possible to construct active spectral-based illumination that includes but is not limited to containing sharp cutoffs to act as filters or forming complex spectra, varying the intensity of light at discrete wavelengths. We have characterized and tested a pure NIR, 760 nm to 1600 nm, DLP hyperspectral reflectance imaging system. In its simplest application, the NIR system can be used to quantify the percentage of water in a subject, enabling edema visualization. It can also be used to map vein structure in a patient in real time. During gall bladder surgery, this system could be invaluable in imaging bile through fatty tissue, aiding surgeons in locating the common bile duct in real time without injecting any contrast agents.

  15. An Investigation of Implicit Active Contours for Scientific Image Segmentation

    SciTech Connect

    Weeratunga, S K; Kamath, C

    2003-10-29

    The use of partial differential equations in image processing has become an active area of research in the last few years. In particular, active contours are being used for image segmentation, either explicitly as snakes, or implicitly through the level set approach. In this paper, we consider the use of the implicit active contour approach for segmenting scientific images of pollen grains obtained using a scanning electron microscope. Our goal is to better understand the pros and cons of these techniques and to compare them with the traditional approaches such as the Canny and SUSAN edge detectors. The preliminary results of our study show that the level set method is computationally expensive and requires the setting of several different parameters. However, it results in closed contours, which may be useful in separating objects from the background in an image.

  16. Modeling approaches for active systems

    NASA Astrophysics Data System (ADS)

    Herold, Sven; Atzrodt, Heiko; Mayer, Dirk; Thomaier, Martin

    2006-03-01

    To solve a wide range of vibration problems with the active structures technology, different simulation approaches for several models are needed. The selection of an appropriate modeling strategy is depending, amongst others, on the frequency range, the modal density and the control target. An active system consists of several components: the mechanical structure, at least one sensor and actuator, signal conditioning electronics and the controller. For each individual part of the active system the simulation approaches can be different. To integrate the several modeling approaches into an active system simulation and to ensure a highly efficient and accurate calculation, all sub models must harmonize. For this purpose, structural models considered in this article are modal state-space formulations for the lower frequency range and transfer function based models for the higher frequency range. The modal state-space formulations are derived from finite element models and/or experimental modal analyses. Consequently, the structure models which are based on transfer functions are directly derived from measurements. The transfer functions are identified with the Steiglitz-McBride iteration method. To convert them from the z-domain to the s-domain a least squares solution is implemented. An analytical approach is used to derive models of active interfaces. These models are transferred into impedance formulations. To couple mechanical and electrical sub-systems with the active materials, the concept of impedance modeling was successfully tested. The impedance models are enhanced by adapting them to adequate measurements. The controller design strongly depends on the frequency range and the number of modes to be controlled. To control systems with a small number of modes, techniques such as active damping or independent modal space control may be used, whereas in the case of systems with a large number of modes or with modes that are not well separated, other control

  17. Neutron imaging for geothermal energy systems

    SciTech Connect

    Bingham, Philip R; Anovitz, Lawrence {Larry} M; Polsky, Yarom

    2013-01-01

    Geothermal systems extract heat energy from the interior of the earth using a working fluid, typically water. Three components are required for a commercially viable geothermal system: heat, fluid, and permeability. Current commercial electricity production using geothermal energy occurs where the three main components exist naturally. These are called hydrothermal systems. In the US, there is an estimated 30 GW of base load electrical power potential for hydrothermal sites. Next generation geothermal systems, named Enhanced Geothermal Systems (EGS), have an estimated potential of 4500 GW. EGSs lack in-situ fluid, permeability or both. As such, the heat exchange system must be developed or engineered within the rock. The envisioned method for producing permeability in the EGS reservoir is hydraulic fracturing, which is rarely practiced in the geothermal industry, and not well understood for the rocks typically present in geothermal reservoirs. High costs associated with trial and error learning in the field have led to an effort to characterize fluid flow and fracturing mechanisms in the laboratory to better understand how to design and manage EGS reservoirs. Neutron radiography has been investigated for potential use in this characterization. An environmental chamber has been developed that is suitable for reproduction of EGS pressures and temperatures and has been tested for both flow and precipitations studies with success for air/liquid interface imaging and 3D reconstruction of precipitation within the core.

  18. APPLEPIPS /Apple Personal Image Processing System/ - An interactive digital image processing system for the Apple II microcomputer

    NASA Technical Reports Server (NTRS)

    Masuoka, E.; Rose, J.; Quattromani, M.

    1981-01-01

    Recent developments related to microprocessor-based personal computers have made low-cost digital image processing systems a reality. Image analysis systems built around these microcomputers provide color image displays for images as large as 256 by 240 pixels in sixteen colors. Descriptive statistics can be computed for portions of an image, and supervised image classification can be obtained. The systems support Basic, Fortran, Pascal, and assembler language. A description is provided of a system which is representative of the new microprocessor-based image processing systems currently on the market. While small systems may never be truly independent of larger mainframes, because they lack 9-track tape drives, the independent processing power of the microcomputers will help alleviate some of the turn-around time problems associated with image analysis and display on the larger multiuser systems.

  19. QI2S - Quick Image Interpretation System

    NASA Astrophysics Data System (ADS)

    Naghmouchi, Jamin; Aviely, Peleg; Ginosar, Ran; Ober, Giovanna; Bischoff, Ole; Nadler, Ron; Guiser, David; Citroen, Meira; Freddi, Riccardo; Berekovic, Mladen

    2015-09-01

    The evolution of the Earth Observation mission will be driven by many factors, and the deveploment of new processing paradigms to facilitate data downlink, handling and storage will be a key factor. Next generation EO satellites will generate a great amount of data at a very high data rate, both radar and optical. Real-time onboard processing can be the solution to reduce data downlink and management on ground. Radiometric, geometric, and atmospheric corrections of EO data as well as material/object detection in addition to the well-known needs for image compression and signal processing can be performed directly on board and the aim of QI2S project is to demonstrate this. QI2S, a concept prototype system for novel onboard image processing and image interpretation which has been designed, developed and validated in the framework of an EU FP7 project, targets these needs and makes a significant step towards exceeding current roadmaps of leading space agencies for future payload processors. The QI2S system features multiple chip components of the RC64, a novel rad-hard 64-core signal processing chip, which targets DSP performance of 75 GMACs (16bit), 150 GOPS and 38 single precision GFLOPS while dissipating less than 10 Watts. It integrates advanced DSP cores with a multibank shared memory and a hardware scheduler, also supporting DDR2/3 memory and twelve 3.125 Gbps full duplex high-speed serial links using SpaceFibre and other protocols. The processor is being developed within the European FP7 Framework Program and will be qualified to the highest space standards.

  20. FLIR systems submicro rotary stirling cycle IDCA for imaging systems

    NASA Astrophysics Data System (ADS)

    Uri, Bin-Nun

    2011-06-01

    The advantages of the common Rotary Stirling cycle coolers over the Split Stirling Linear are the overall size, light weight, low cooler input power and high efficiency. The main disadvantage has always been self induced vibration. Self induced vibration is a major consideration in the design of stabilized IR imaging systems/(GIMBALS) due to the effect it has on image quality i.e. Jitter. The "irregular shape" of the Rotary cooling engine attached to the payload and optics is also a problem in terms of the limits it has on optical system size. To address these issues, FLIR Systems Inc in Boston MA, developed a new rotary Stirling cycle cooling engine known as the FLIR Submicro Cooler. The Submicro is now in production and has been applied in a few products especially in FLIR"S smallest GIMBAL which measures 7.0 inch in spherical diameter. In this paper we discuss the improvements made in terms of IDCA implementation in stabilized imaging systems.

  1. FLIR systems submicro rotary stirling cycle IDCA for imaging systems

    NASA Astrophysics Data System (ADS)

    Bin-Nun, Uri

    2011-05-01

    The advantages of the common Rotary Stirling cycle coolers over the Split Stirling Linear are the overall size, light weight, low cooler input power and high efficiency. The main disadvantage has always been self induced vibration. Self induced vibration is a major consideration in the design of stabilized IR imaging systems/(GIMBALS) due to the effect it has on image quality i.e. Jitter. The "irregular shape" of the Rotary cooling engine attached to the payload and optics is also a problem in terms of the limits it has on optical system size. To address these issues, FLIR Systems Inc in Boston MA, developed a new rotary Stirling cycle cooling engine known as the FLIR Submicro Cooler. The Submicro is now in production and has been applied in a few products especially in FLIR"S smallest GIMBAL which measures 7.0 inch in spherical diameter. In this paper we discuss the improvements made in terms of IDCA implementation in stabilized imaging systems.

  2. Image engine: an integrated multimedia clinical information system.

    PubMed

    Lowe, H J; Buchanan, B G; Cooper, G F; Kaplan, B; Vries, J K

    1995-01-01

    Image Engine is a microcomputer-based system for the integration, storage, retrieval, and sharing of digitized clinical images. The system seeks to address the problem of integrating a wide range of clinically important images with the text-based electronic patient record. Rather than create a single, integrated database system for all clinical data, we are developing a separate image database system that creates real-time, dynamic links to other network-based clinical databases. To the user, this system will present an integrated multimedia representation of the patient record, providing access to both the image and text-based data required for effective clinical decision making. PMID:8591216

  3. Image engine: an integrated multimedia clinical information system.

    PubMed

    Lowe, H J; Buchanan, B G; Cooper, G F; Kaplan, B; Vries, J K

    1995-01-01

    Image Engine is a microcomputer-based system for the integration, storage, retrieval, and sharing of digitized clinical images. The system seeks to address the problem of integrating a wide range of clinically important images with the text-based electronic patient record. Rather than create a single, integrated database system for all clinical data, we are developing a separate image database system that creates real-time, dynamic links to other network-based clinical databases. To the user, this system will present an integrated multimedia representation of the patient record, providing access to both the image and text-based data required for effective clinical decision making.

  4. Video guidance, landing, and imaging systems

    NASA Technical Reports Server (NTRS)

    Schappell, R. T.; Knickerbocker, R. L.; Tietz, J. C.; Grant, C.; Rice, R. B.; Moog, R. D.

    1975-01-01

    The adaptive potential of video guidance technology for earth orbital and interplanetary missions was explored. The application of video acquisition, pointing, tracking, and navigation technology was considered to three primary missions: planetary landing, earth resources satellite, and spacecraft rendezvous and docking. It was found that an imaging system can be mechanized to provide a spacecraft or satellite with a considerable amount of adaptability with respect to its environment. It also provides a level of autonomy essential to many future missions and enhances their data gathering ability. The feasibility of an autonomous video guidance system capable of observing a planetary surface during terminal descent and selecting the most acceptable landing site was successfully demonstrated in the laboratory. The techniques developed for acquisition, pointing, and tracking show promise for recognizing and tracking coastlines, rivers, and other constituents of interest. Routines were written and checked for rendezvous, docking, and station-keeping functions.

  5. Adaptive Optics Imaging of Solar System Objects

    NASA Technical Reports Server (NTRS)

    Roddier, Francois; Owen, Toby

    1997-01-01

    Most solar system objects have never been observed at wavelengths longer than the R band with an angular resolution better than 1 sec. The Hubble Space Telescope itself has only recently been equipped to observe in the infrared. However, because of its small diameter, the angular resolution is lower than that one can now achieved from the ground with adaptive optics, and time allocated to planetary science is limited. We have been using adaptive optics (AO) on a 4-m class telescope to obtain 0.1 sec resolution images solar system objects at far red and near infrared wavelengths (0.7-2.5 micron) which best discriminate their spectral signatures. Our efforts has been put into areas of research for which high angular resolution is essential, such as the mapping of Titan and of large asteroids, the dynamics and composition of Neptune stratospheric clouds, the infrared photometry of Pluto, Charon, and close satellites previously undetected from the ground.

  6. Adaptive Optics Imaging of Solar System Objects

    NASA Technical Reports Server (NTRS)

    Roddier, Francois; Owen, Toby

    1999-01-01

    Most solar system objects have never been observed at wavelengths longer than the R band with an angular resolution better than 1". The Hubble Space Telescope itself has only recently been equipped to observe in the infrared. However, because of its small diameter, the angular resolution is lower than that one can now achieved from the ground with adaptive optics, and time allocated to planetary science is limited. We have successfully used adaptive optics on a 4-m class telescope to obtain 0.1" resolution images of solar system objects in the far red and near infrared (0.7-2.5 microns), aE wavelengths which best discl"lmlnate their spectral signatures. Our efforts have been put into areas of research for which high angular resolution is essential.

  7. SORIS—A standoff radiation imaging system

    NASA Astrophysics Data System (ADS)

    Zelakiewicz, Scott; Hoctor, Ralph; Ivan, Adrian; Ross, William; Nieters, Edward; Smith, William; McDevitt, Daniel; Wittbrodt, Michael; Milbrath, Brian

    2011-10-01

    The detection of radiological and special nuclear material within the country's borders is a crucial component of the national security network. Being able to detect small amounts of radiological material at large distances is especially important for search applications. To provide this capability General Electric's Research Center has developed, as a part of DNDO's standoff radiation detection system advanced technology demonstration (SORDS-ATD) program, a standoff radiation imaging system (SORIS). This vehicle-based system is capable of detecting weak sources at large distances in relatively short times. To accomplish this, GE has developed a novel coded aperture detector based on commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.

  8. Distributed health care imaging information systems

    NASA Astrophysics Data System (ADS)

    Thompson, Mary R.; Johnston, William E.; Guojun, Jin; Lee, Jason; Tierney, Brian; Terdiman, Joseph F.

    1997-05-01

    We have developed an ATM network-based system to collect and catalogue cardio-angiogram videos from the source at a Kaiser central facility and make them available for viewing by doctors at primary care Kaiser facilities. This an example of the general problem of diagnostic data being generated at tertiary facilities, while the images, or other large data objects they produce, need to be used from a variety of other locations such as doctor's offices or local hospitals. We describe the use of a highly distributed computing and storage architecture to provide all aspects of collecting, storing, analyzing, and accessing such large data-objects in a metropolitan area ATM network. Our large data-object management system provides network interface between the object sources, the data management system and the user of the data. As the data is being stored, a cataloguing system automatically creates and stores condensed versions of the data, textural metadata and pointers to the original data. The catalogue system provides a Web-based graphical interface to the data. The user is able the view the low-resolution data with a standard Internet connection and Web browser. If high-resolution is required, a high-speed connection and special application programs can be used to view the high-resolution original data.

  9. Image processing system to analyze droplet distributions in sprays

    NASA Technical Reports Server (NTRS)

    Bertollini, Gary P.; Oberdier, Larry M.; Lee, Yong H.

    1987-01-01

    An image processing system was developed which automatically analyzes the size distributions in fuel spray video images. Images are generated by using pulsed laser light to freeze droplet motion in the spray sample volume under study. This coherent illumination source produces images which contain droplet diffraction patterns representing the droplets degree of focus. The analysis is performed by extracting feature data describing droplet diffraction patterns in the images. This allows the system to select droplets from image anomalies and measure only those droplets considered in focus. Unique features of the system are the totally automated analysis and droplet feature measurement from the grayscale image. The feature extraction and image restoration algorithms used in the system are described. Preliminary performance data is also given for two experiments. One experiment gives a comparison between a synthesized distribution measured manually and automatically. The second experiment compares a real spray distribution measured using current methods against the automatic system.

  10. An image retrieval system for three-dimensional image

    NASA Astrophysics Data System (ADS)

    Lee, Chu-Hui; Lin, Jin-Shu

    2013-07-01

    With the progress of the age, the popularization of the computer and the internet, the text, images, photographs and varieties of multimedia will be uploaded to groups of the network space or cloud storage space by users. Thus, the multimedia data and technology have to renew and transfer by user constantly. How to search the images economically is a significant issue. This paper will focus on 3D images for in-depth investigate. It will propose an efficient 3D searching method. The analytical object is used by three-dimensional trademark gallery of the Intellectual Property Office of the Ministry of Economic Affairs, R.O.C. One three-dimensional trademark image expresses by a set of 2D images. This paper uses Harris Corner detection and combines CPDH (contour points distribution histogram) method to extract the shape feature and uses color histogram to refine the color feature. And then, the two features help to retrieve the similar 3D images. Experiment verifies that the method we proposed is effective.

  11. Computer Human Interaction for Image Information Systems.

    ERIC Educational Resources Information Center

    Beard, David Volk

    1991-01-01

    Presents an approach to developing viable image computer-human interactions (CHI) involving user metaphors for comprehending image data and methods for locating, accessing, and displaying computer images. A medical-image radiology workstation application is used as an example, and feedback and evaluation methods are discussed. (41 references) (LRW)

  12. Range accuracy analysis of streak tube imaging lidar systems

    NASA Astrophysics Data System (ADS)

    Ye, Guangchao; Fan, Rongwei; Chen, Zhaodong; Yuan, Wei; Chen, Deying; He, Ping

    2016-02-01

    Streak tube imaging lidar (STIL) is an active imaging system that has a high range accuracy and a wide range gate with the use of a pulsed laser transmitter and streak tube receiver to produce 3D range images. This work investigates the range accuracy performance of STIL systems based on a peak detection algorithm, taking into account the effects of blurring of the image. A theoretical model of the time-resolved signal distribution, including the static blurring width in addition to the laser pulse width, is presented, resulting in a modified range accuracy analysis. The model indicates that the static blurring width has a significant effect on the range accuracy, which is validated by both the simulation and experimental results. By using the optimal static blurring width, the range accuracies are enhanced in both indoor and outdoor experiments, with a stand-off distance of 10 m and 1700 m, respectively, and corresponding, best range errors of 0.06 m and 0.25 m were achieved in a daylight environment.

  13. Simulation of signal-to-noise ratio for the laser range-gated imaging system

    NASA Astrophysics Data System (ADS)

    Liang, Weiwei; Chen, Qianrong; Hao, Yongwang; Guo, Hao; Zhang, Wenpan

    2015-10-01

    The laser active imaging system is widely used in night vision, underwater imaging, three-dimension scene imaging and other civilian applications, and the system's detected range increase greatly comparing with the passive imaging system. In recent years, with rapid development of sensor and laser source technique, the laser range-gated imaging system is achieved based on high peak power pulsed laser and gated intensified CCD(ICCD), and it is well known for its properties such as high suppression of backscatter noise from fog and other obscurants, high resolution, long detection range and direct visualization. However, the performance of the laser range-gated imaging system is seriously affected by many factors, and the relationships between system's Signal-to-Noise Ratio (SNR) and influence factors are not further elaborated. In this paper, the simulation of SNR for the laser range-gated imaging system is studied. The principle of the laser range-gated imaging system is shown firstly, and the range equation is derived by means of deducing laser illuminating model according to the principle of laser radar and the characters of objects and the detectors. And then, the sources of noise are analyzed by accurately modeling all noise sources in the detection system, the model of SNR for laser range-gated imaging system is established. Finally, the relationships between SNR of system and influence factors such as gating time, laser pulse width and repetition frequency are discussed, and correspondingly the solutions are proposed.

  14. Imaging and characterizing root systems using electrical impedance tomography

    NASA Astrophysics Data System (ADS)

    Kemna, A.; Weigand, M.; Kelter, M.; Pfeifer, J.; Zimmermann, E.; Walter, A.

    2011-12-01

    Root architecture, growth, and activity play an essential role regarding the nutrient uptake of roots in soils. While in recent years advances could be achieved concerning the modeling of root systems, measurement methods capable of imaging, characterizing, and monitoring root structure and dynamics in a non-destructive manner are still lacking, in particular at the field scale. We here propose electrical impedance tomography (EIT) for the imaging of root systems. The approach takes advantage of the low-frequency capacitive electrical properties of the soil-root interface and the root tissue. These properties are based on the induced migration of ions in an externally applied electric field and give rise to characteristic impedance spectra which can be measured by means of electrical impedance spectroscopy. The latter technique was already successfully applied in the 10 Hz to 1 MHz range by Ozier-Lafontaine and Bajazet (2005) to monitor root growth of tomato. We here apply the method in the 1 mHz to 45 kHz range, requiring four-electrode measurements, and demonstrate its implementation and potential in an imaging framework. Images of real and imaginary components of complex electrical conductivity are computed using a finite-element based inversion algorithm with smoothness-constraint regularization. Results from laboratory measurements on rhizotrons with different root systems (barley, rape) show that images of imaginary conductivity delineate the spatial extent of the root system under investigation, while images of real conductivity show a less clear response. As confirmed by numerical simulations, the latter could be explained by the partly compensating electrical conduction properties of epidermis (resistive) and inner root cells (conductive), indicating the limitations of conventional electrical resistivity tomography. The captured spectral behavior exhibits two distinct relaxation processes with Cole-Cole type signatures, which we interpret as the responses

  15. Compact multi-spectral imaging system for dermatology and neurosurgery

    NASA Astrophysics Data System (ADS)

    Noordmans, Herke Jan; de Roode, Rowland; Verdaasdonk, Rudolf

    2007-03-01

    A compact multi-spectral imaging system is presented as diagnostic tool in dermatology and neurosurgery. Using an electronically tunable filter, a sensitive high resolution digital camera, 140 spectral images from 400 nm up to 720 nm are acquired in 40 s. Advanced image processing algorithms are used to enable interactive acquisition, viewing, image registration and image analysis. Experiments in the department of dermatology and neurosurgery show that multispectral imaging reveals much more detail than conventional medical photography or a surgical microscope, as images can be reprocessed to enhance the view on e.g. tumor boundaries. Using a hardware-based interactive registration algorithm, multi-spectral images can be aligned to correct for motion occurred during image acquisition or to compare acquisitions from different moments in time. The system shows to be a powerful diagnostics tool for medical imaging in the visual and near IR range.

  16. Imaging Granzyme B Activity Assesses Immune-Mediated Myocarditis

    PubMed Central

    Weissleder, Ralph; Lichtman, Andrew H.; McCarthy, Jason R.; Libby, Peter

    2015-01-01

    Rationale The development of molecular imaging approaches that assess specific immunopathologic mechanisms can advance the study of myocarditides. Objective This study validates a novel molecular imaging tool that enables the in vivo visualization of granzyme B activity, a major effector of cytotoxic CD8+ T lymphocytes. Methods and Results We synthesized and optimized a fluorogenic substrate capable of reporting on granzyme B activity and examined its specificity ex vivo in mice hearts with experimental cytotoxic CD8+ T lymphocyte-mediated myocarditis using fluorescence reflectance imaging (FRI), validated by histologic examination. In vivo experiments localized granzyme B activity in hearts with acute myocarditis monitored by fluorescent molecular tomography in conjunction with co-registered computed tomography imaging (FMT-CT). A model anti-inflammatory intervention (dexamethasone administration) in vivo reduced granzyme B activity (vehicle vs. dexamethasone: 504±263 vs. 194±77 fluorescence intensities in hearts, P=0.002). Conclusions Molecular imaging of granzyme B activity can visualize T cell-mediated myocardial injury and monitor the response to an anti-inflammatory intervention. PMID:26199323

  17. PAMS photo image retrieval prototype system requirements specification

    SciTech Connect

    Conner, M.L.

    1996-04-30

    This project is part of the Photo Audiovisual Management System (PAMS). The project was initially identified in 1989 and has since been has been worked on under various names such as Image Retrieval and Viewing System, Photo Image Retrieval Subsystem and Image Processing and Compression System. This document builds upon the information collected and the analysis performed in the earlier phases of this project. The PAMS Photo Imaging subsystem will provide the means of capturing low resolution digital images from Photography`s negative files and associating the digital images with a record in the PAMS photo database. The digital images and key photo identification information will be accessible to HAN users to assist in locating and identifying specific photographs. After identifying desired photographs, users may request photo prints or high resolution digital images directly from Photography. The digital images captured by this project are for identification purposes only and are not intended to be of sufficient quality for subsequent use.

  18. A New High Frequency Ultrasound Skin Imaging System: Imaging Properties and Clinical in Vivo Results

    NASA Astrophysics Data System (ADS)

    Vogt, M.; Scharenberg, R.; Moussa, G.; Sand, M.; Hoffmann, K.; Altmeyer, P.; Ermert, H.

    In this paper, a new high frequency ultrasound (HFUS) system for high-resolution skin imaging is presented. For imaging, mechanical scans are performed with spherically focused single element transducers. Two separate applicators with different transducers are utilized to fulfill the different requirements for imaging the skin with 20MHz ultrasound and for lower range high resolution imaging of the uppermost skin layers with HFUS in the 100MHz range. Clinical images were acquired in the imaging lab of the Dermatological University Hospital. Imaging results of wound healing process and skin lesion nevus investigations are presented

  19. Experiments and models of active and thermal imaging under bad weather conditions

    NASA Astrophysics Data System (ADS)

    Bernard, Erwan; Riviere, Nicolas; Renaudat, Mathieu; Guiset, Pierrick; Pealat, Michel; Zenou, Emmanuel

    2013-10-01

    Thermal imaging cameras are widely used in military contexts for their night vision capabilities and their observation range; there are based on passive infrared sensors (e.g. MWIR or LWIR range). Under bad weather conditions or when the target is partially hidden (e.g. foliage, military camouflage) they are more and more complemented by active imaging systems, a key technology to perform target identification at long range. The 2D flash imaging technique is based on a high powered pulsed laser source that illuminates the entire scene and a fast gated camera as the imaging system. Both technologies are well experienced under clear meteorological conditions; models including atmospheric effects such as turbulence are able to predict accurately their performances. However, under bad weather conditions such as rain, haze or snow, these models are not relevant. This paper introduces new models to predict performances under bad weather conditions for both active and infrared imaging systems. We point out their effects on controlled physical parameters (extinction, transmission, spatial resolution, thermal background, speckle, turbulence). Then we develop physical models to describe their intrinsic characteristics and their impact on the imaging system performances. Finally, we approximate these models to have a "first order" model easy to deploy for industrial applications. This theoretical work will be validated on real active and infrared data.

  20. IMIS: An intelligence microscope imaging system

    NASA Technical Reports Server (NTRS)

    Caputo, Michael; Hunter, Norwood; Taylor, Gerald

    1994-01-01

    Until recently microscope users in space relied on traditional microscopy techniques that required manual operation of the microscope and recording of observations in the form of written notes, drawings, or photographs. This method was time consuming and required the return of film and drawings from space for analysis. No real-time data analysis was possible. Advances in digital and video technologies along with recent developments in article intelligence will allow future space microscopists to have a choice of three additional modes of microscopy: remote coaching, remote control, and automation. Remote coaching requires manual operations of the microscope with instructions given by two-way audio/video transmission during critical phases of the experiment. When using the remote mode of microscopy, the Principal Investigator controls the microscope from the ground. The automated mode employs artificial intelligence to control microscope functions and is the only mode that can be operated in the other three modes as well. The purpose of this presentation is to discuss the advantages and disadvantages of the four modes of of microscopy and how the IMIS, a proposed intelligent microscope imaging system, can be used as a model for developing and testing concepts, operating procedures, and equipment design of specifications required to provide a comprehensive microscopy/imaging capability onboard Space Station Freedom.

  1. Network of fully integrated multispecialty hospital imaging systems

    NASA Astrophysics Data System (ADS)

    Dayhoff, Ruth E.; Kuzmak, Peter M.

    1994-05-01

    The Department of Veterans Affairs (VA) DHCP Imaging System records clinically significant diagnostic images selected by medical specialists in a variety of departments, including radiology, cardiology, gastroenterology, pathology, dermatology, hematology, surgery, podiatry, dental clinic, and emergency room. These images are displayed on workstations located throughout a medical center. All images are managed by the VA's hospital information system, allowing integrated displays of text and image data across medical specialties. Clinicians can view screens of `thumbnail' images for all studies or procedures performed on a selected patient. Two VA medical centers currently have DHCP Imaging Systems installed, and others are planned. All VA medical centers and other VA facilities are connected by a wide area packet-switched network. The VA's electronic mail software has been modified to allow inclusion of binary data such as images in addition to the traditional text data. Testing of this multimedia electronic mail system is underway for medical teleconsultation.

  2. A Ferret-based gastrointestinal image retrieval system.

    PubMed

    Bedrick, Steven; Kalpathy-Cramer, Jayashree

    2007-01-01

    We developed a web-based interface for image retrieval and cluster analysis system. The system handles search queries using Ferret, a port to the Ruby language of the Apache Lucene indexing and searching system. The system uses de-identified endoscopic images from the Clinical Outcomes Research Initiative data repository, and is designed for use by students and researchers.

  3. An image identification system of seal with fingerprint based on CMOS image sensor

    NASA Astrophysics Data System (ADS)

    Xue, Xu-cheng; Zhang, Shu-yan; Guo, Yong-fei

    2006-01-01

    CMOS image sensors now become increasingly competitive with respect to their CCD counterparts, while adding advantages such as no blooming, simpler driving requirements and the potential of on-chip integration of sensor, analog signal conditioning circuits, A/D converter and digital processing functions. Furthermore, CMOS sensors are the best choices for low-cost imaging systems. An image identification system based on CMOS image sensor is used to identify the seal images that include fingerprint, and then determine whether the seal is fake or not. The system consists of a color CMOS image sensor (OV2610), a buffer memory, a CPLD, a MCU (P89C61X2), a USB2.0 interface chip (ISP1581) and a personal computer. The CPLD implement the logic and timing of the system. The MCU and the USB2.0 interface chip deal with the communications between the images acquisition system and PC. Thus PC can send some parameters and commands to the images acquisition system and also read image data from it. The identification of the images of seal is processed by the PC. The structure and scheme of the system are discussed in detail in this paper. Several test images of seal taken by the system are also provided in the paper.

  4. An active tactile perception system

    NASA Astrophysics Data System (ADS)

    Petriu, E.; Greenspan, M.; Gelinas, F.; McMath, W. S.; Yeung, S. K.

    System development and application aspects are described for an experimental robotic system for the tactile perception of the global geometric profile of object surfaces which are larger than the dimensions of the tactile sensor. Local cutaneous information provided by a tactile sensor is integrated with the kinesthetic position parameters of a robot arm, resulting in a 3D geometric model of the tactile sensor pose on the explored object surface. Currently available tactile sensors provide poor information on the geometric profile of 3D object surfaces. In order to maximize the information available for 3D analysis, an instrumented passive compliant wrist was used to attach a pressure measuring tactile probe to the robot arm carrier. Data was collected by a noncompliant planar sensing array in direct contact with an object surface. Information recorded includes the following: positional and orientation data on the robot arm manipulator, passive compliance kinesthetic data as measured by the kinematics of the wrist, and cutaneous tactile data represented by the binary image of the sensors pose on the object. The dimensions of the sensor array were found to be a critical factor in system performance. Use of a large array results in fewer touch poses being required to explore an object's surface, on the other hand a large planar array will touch fewer and higher peaks thus missing surface detail. To improve performance, there is a need to design tactile sensors specifically for geometric profile measuring.

  5. Multimodal digital color imaging system for facial skin lesion analysis

    NASA Astrophysics Data System (ADS)

    Bae, Youngwoo; Lee, Youn-Heum; Jung, Byungjo

    2008-02-01

    In dermatology, various digital imaging modalities have been used as an important tool to quantitatively evaluate the treatment effect of skin lesions. Cross-polarization color image was used to evaluate skin chromophores (melanin and hemoglobin) information and parallel-polarization image to evaluate skin texture information. In addition, UV-A induced fluorescent image has been widely used to evaluate various skin conditions such as sebum, keratosis, sun damages, and vitiligo. In order to maximize the evaluation efficacy of various skin lesions, it is necessary to integrate various imaging modalities into an imaging system. In this study, we propose a multimodal digital color imaging system, which provides four different digital color images of standard color image, parallel and cross-polarization color image, and UV-A induced fluorescent color image. Herein, we describe the imaging system and present the examples of image analysis. By analyzing the color information and morphological features of facial skin lesions, we are able to comparably and simultaneously evaluate various skin lesions. In conclusion, we are sure that the multimodal color imaging system can be utilized as an important assistant tool in dermatology.

  6. Multimodality image guidance system integrating X-ray fluoroscopy and ultrasound image streams with electromagnetic tracking

    NASA Astrophysics Data System (ADS)

    Gutiérrez, Luis F.; Shechter, Guy; Stanton, Douglas; Dalal, Sandeep; Elgort, Daniel; Manzke, Robert; Chan, Raymond C.; Zagorchev, Lyubomir

    2007-03-01

    This work presents an integrated system for multimodality image guidance of minimally invasive medical procedures. This software and hardware system offers real-time integration and registration of multiple image streams with localization data from navigation systems. All system components communicate over a local area Ethernet network, enabling rapid and flexible deployment configurations. As a representative configuration, we use X-ray fluoroscopy (XF) and ultrasound (US) imaging. The XF imaging system serves as the world coordinate system, with gantry geometry derived from the imaging system, and patient table position tracked with a custom-built measurement device using linear encoders. An electromagnetic (EM) tracking system is registered to the XF space using a custom imaging phantom that is also tracked by the EM system. The RMS fiducial registration error for the EM to X-ray registration was 2.19 mm, and the RMS target registration error measured with an EM-tracked catheter was 8.81 mm. The US image stream is subsequently registered to the XF coordinate system using EM tracking of the probe, following a calibration of the US image within the EM coordinate system. We present qualitative results of the system in operation, demonstrating the integration of live ultrasound imaging spatially registered to X-ray fluoroscopy with catheter localization using electromagnetic tracking.

  7. A database system to support image algorithm evaluation

    NASA Technical Reports Server (NTRS)

    Lien, Y. E.

    1977-01-01

    The design is given of an interactive image database system IMDB, which allows the user to create, retrieve, store, display, and manipulate images through the facility of a high-level, interactive image query (IQ) language. The query language IQ permits the user to define false color functions, pixel value transformations, overlay functions, zoom functions, and windows. The user manipulates the images through generic functions. The user can direct images to display devices for visual and qualitative analysis. Image histograms and pixel value distributions can also be computed to obtain a quantitative analysis of images.

  8. Validation of an image simulation technique for two computed radiography systems: An application to neonatal imaging

    SciTech Connect

    Smans, Kristien; Vandenbroucke, Dirk; Pauwels, Herman; Struelens, Lara; Vanhavere, Filip; Bosmans, Hilde

    2010-05-15

    Purpose: The purpose of this study is to develop a computer model to simulate the image acquisition for two computed radiography (CR) imaging systems used for neonatal chest imaging: (1) The Agfa ADC Compact, a flying spot reader with powder phosphor image plates (MD 40.0); and (2) the Agfa DX-S, a line-scanning CR reader with needle crystal phosphor image plates (HD 5.0). The model was then applied to compare the image quality of the two CR imaging systems. Methods: Monte Carlo techniques were used to simulate the transport of primary and scattered x rays in digital x-ray systems. The output of the Monte Carlo program was an image representing the energy absorbed in the detector material. This image was then modified using physical characteristics of the CR imaging systems to account for the signal intensity variations due to the heel effect along the anode-cathode axis, the spatial resolution characteristics of the imaging system, and the various sources of image noise. The simulation was performed for typical acquisition parameters of neonatal chest x-ray examinations. To evaluate the computer model, the authors compared the threshold-contrast detectability in simulated and experimentally acquired images of a contrast-detail phantom. Threshold-contrast curves were computed using a commercially available scoring program. Results: The threshold-contrast curves of the simulated and experimentally acquired images show good agreement; for the two CR systems, 93% of the threshold diameters calculated from the simulated images fell within the confidence intervals of the threshold diameter calculated from the experimentally assessed images. Moreover, the superiority of needle based CR plates for neonatal imaging was confirmed. Conclusions: The good agreement between simulated and experimental acquired results indicates that the computer model is accurate.

  9. Planar and cylindrical active microwave temperature imaging: numerical simulations.

    PubMed

    Rius, J M; Pichot, C; Jofre, L; Bolomey, J C; Joachimowicz, N; Broquetas, A; Ferrando, M

    1992-01-01

    A comparative study at 2.45 GHz concerning both measurement and reconstruction parameters for planar and cylindrical configurations is presented. For the sake of comparison, a numerical model consisting of two nonconcentric cylinders is considered and reconstructed using both geometries from simulated experimental data. The scattered fields and reconstructed images permit extraction of very useful information about dynamic range, sensitivity, resolution, and quantitative image accuracy for the choice of the configuration in a particular application. Both geometries can measure forward and backward scattered fields. The backscattering measurement improves the image resolution and reconstruction in lossy mediums, but, on the other hand, has several dynamic range difficulties. This tradeoff between forward only and forward-backward field measurement is analyzed. As differential temperature imaging is a weakly scattering problem, Born approximation algorithms can be used. The simplicity of Born reconstruction algorithms and the use of FFT make them very attractive for real-time biomedical imaging systems. PMID:18222887

  10. Molecular Imaging of Activated Platelets Allows the Detection of Pulmonary Embolism with Magnetic Resonance Imaging

    PubMed Central

    Heidt, Timo; Ehrismann, Simon; Hövener, Jan-Bernd; Neudorfer, Irene; Hilgendorf, Ingo; Reisert, Marco; Hagemeyer, Christoph E.; Zirlik, Andreas; Reinöhl, Jochen; Bode, Christoph; Peter, Karlheinz; von Elverfeldt, Dominik; von zur Muhlen, Constantin

    2016-01-01

    Early and reliable detection of pulmonary embolism (PE) is critical for improving patient morbidity and mortality. The desire for low-threshold screening for pulmonary embolism is contradicted by unfavorable radiation of currently used computed tomography or nuclear techniques, while standard magnetic resonance imaging still struggles to provide sufficient diagnostic sensitivity in the lung. In this study we evaluate a molecular-targeted contrast agent against activated platelets for non-invasive detection of murine pulmonary thromboembolism using magnetic resonance imaging. By intravenous injection of human thrombin, pulmonary thromboembolism were consistently induced as confirmed by immunohistochemistry of the lung. Magnetic resonance imaging after thrombin injection showed local tissue edema in weighted images which co-localized with the histological presence of pulmonary thromboembolism. Furthermore, injection of a functionalized contrast agent targeting activated platelets provided sensitive evidence of focal accumulation of activated platelets within the edematous area, which, ex vivo, correlated well with the size of the pulmonary embolism. In summary, we here show delivery and specific binding of a functionalized molecular contrast agent against activated platelets for targeting pulmonary thromboembolism. Going forward, molecular imaging may provide new opportunities to increase sensitivity of magnetic resonance imaging for detection of pulmonary embolism. PMID:27138487

  11. Molecular Imaging of Activated Platelets Allows the Detection of Pulmonary Embolism with Magnetic Resonance Imaging.

    PubMed

    Heidt, Timo; Ehrismann, Simon; Hövener, Jan-Bernd; Neudorfer, Irene; Hilgendorf, Ingo; Reisert, Marco; Hagemeyer, Christoph E; Zirlik, Andreas; Reinöhl, Jochen; Bode, Christoph; Peter, Karlheinz; von Elverfeldt, Dominik; von Zur Muhlen, Constantin

    2016-01-01

    Early and reliable detection of pulmonary embolism (PE) is critical for improving patient morbidity and mortality. The desire for low-threshold screening for pulmonary embolism is contradicted by unfavorable radiation of currently used computed tomography or nuclear techniques, while standard magnetic resonance imaging still struggles to provide sufficient diagnostic sensitivity in the lung. In this study we evaluate a molecular-targeted contrast agent against activated platelets for non-invasive detection of murine pulmonary thromboembolism using magnetic resonance imaging. By intravenous injection of human thrombin, pulmonary thromboembolism were consistently induced as confirmed by immunohistochemistry of the lung. Magnetic resonance imaging after thrombin injection showed local tissue edema in weighted images which co-localized with the histological presence of pulmonary thromboembolism. Furthermore, injection of a functionalized contrast agent targeting activated platelets provided sensitive evidence of focal accumulation of activated platelets within the edematous area, which, ex vivo, correlated well with the size of the pulmonary embolism. In summary, we here show delivery and specific binding of a functionalized molecular contrast agent against activated platelets for targeting pulmonary thromboembolism. Going forward, molecular imaging may provide new opportunities to increase sensitivity of magnetic resonance imaging for detection of pulmonary embolism. PMID:27138487

  12. Solar Activity Studies using Microwave Imaging Observations

    NASA Technical Reports Server (NTRS)

    Gopalswamy, N.

    2016-01-01

    We report on the status of solar cycle 24 based on polar prominence eruptions (PEs) and microwave brightness enhancement (MBE) information obtained by the Nobeyama radioheliograph. The north polar region of the Sun had near-zero field strength for more than three years (2012-2015) and ended only in September 2015 as indicated by the presence of polar PEs and the lack of MBE. The zero-polar-field condition in the south started only around 2013, but it ended by June 2014. Thus the asymmetry in the times of polarity reversal switched between cycle 23 and 24. The polar MBE is a good proxy for the polar magnetic field strength as indicated by the high degree of correlation between the two. The cross-correlation between the high- and low-latitude MBEs is significant for a lag of approximately 5.5 to 7.3 years, suggesting that the polar field of one cycle indicates the sunspot number of the next cycle in agreement with the Babcock-Leighton mechanism of solar cycles. The extended period of near-zero field in the north-polar region should result in a weak and delayed sunspot activity in the northern hemisphere in cycle 25.

  13. Automatic system for detecting pornographic images

    NASA Astrophysics Data System (ADS)

    Ho, Kevin I. C.; Chen, Tung-Shou; Ho, Jun-Der

    2002-09-01

    Due to the dramatic growth of network and multimedia technology, people can more easily get variant information by using Internet. Unfortunately, it also makes the diffusion of illegal and harmful content much easier. So, it becomes an important topic for the Internet society to protect and safeguard Internet users from these content that may be encountered while surfing on the Net, especially children. Among these content, porno graphs cause more serious harm. Therefore, in this study, we propose an automatic system to detect still colour porno graphs. Starting from this result, we plan to develop an automatic system to search porno graphs or to filter porno graphs. Almost all the porno graphs possess one common characteristic that is the ratio of the size of skin region and non-skin region is high. Based on this characteristic, our system first converts the colour space from RGB colour space to HSV colour space so as to segment all the possible skin-colour regions from scene background. We also apply the texture analysis on the selected skin-colour regions to separate the skin regions from non-skin regions. Then, we try to group the adjacent pixels located in skin regions. If the ratio is over a given threshold, we can tell if the given image is a possible porno graph. Based on our experiment, less than 10% of non-porno graphs are classified as pornography, and over 80% of the most harmful porno graphs are classified correctly.

  14. Multiple Active Contours Guided by Differential Evolution for Medical Image Segmentation

    PubMed Central

    Cruz-Aceves, I.; Avina-Cervantes, J. G.; Lopez-Hernandez, J. M.; Rostro-Gonzalez, H.; Garcia-Capulin, C. H.; Torres-Cisneros, M.; Guzman-Cabrera, R.

    2013-01-01

    This paper presents a new image segmentation method based on multiple active contours guided by differential evolution, called MACDE. The segmentation method uses differential evolution over a polar coordinate system to increase the exploration and exploitation capabilities regarding the classical active contour model. To evaluate the performance of the proposed method, a set of synthetic images with complex objects, Gaussian noise, and deep concavities is introduced. Subsequently, MACDE is applied on datasets of sequential computed tomography and magnetic resonance images which contain the human heart and the human left ventricle, respectively. Finally, to obtain a quantitative and qualitative evaluation of the medical image segmentations compared to regions outlined by experts, a set of distance and similarity metrics has been adopted. According to the experimental results, MACDE outperforms the classical active contour model and the interactive Tseng method in terms of efficiency and robustness for obtaining the optimal control points and attains a high accuracy segmentation. PMID:23983809

  15. Digital image fusion systems: color imaging and low-light targets

    NASA Astrophysics Data System (ADS)

    Estrera, Joseph P.

    2009-05-01

    This paper presents digital image fusion (enhanced A+B) systems in color imaging and low light target applications. This paper will discuss first the digital sensors that are utilized in the noted image fusion applications which is a 1900x1086 (high definition format) CMOS imager coupled to a Generation III image intensifier for the visible/near infrared (NIR) digital sensor and 320x240 or 640x480 uncooled microbolometer thermal imager for the long wavelength infrared (LWIR) digital sensor. Performance metrics for these digital imaging sensors will be presented. The digital image fusion (enhanced A+B) process will be presented in context of early fused night vision systems such as the digital image fused system (DIFS) and the digital enhanced night vision goggle and later, the long range digitally fused night vision sighting system. Next, this paper will discuss the effects of user display color in a dual color digital image fusion system. Dual color image fusion schemes such as Green/Red, Cyan/Yellow, and White/Blue for image intensifier and thermal infrared sensor color representation, respectively, are discussed. Finally, this paper will present digitally fused imagery and image analysis of long distance targets in low light from these digital fused systems. The result of this image analysis with enhanced A+B digital image fusion systems is that maximum contrast and spatial resolution is achieved in a digital fusion mode as compared to individual sensor modalities in low light, long distance imaging applications. Paper has been cleared by DoD/OSR for Public Release under Ref: 08-S-2183 on August 8, 2008.

  16. Validation of an active transponder for KOMPSAT-5 SAR image calibration

    NASA Astrophysics Data System (ADS)

    Park, Durk Jong; Yeom, Kyung Whan; Ahn, Sang Il; Lim, Hyo Suk

    2014-10-01

    This paper describes the development and validation of a transportable active transponder designed for the image calibration of Korea Multi-Purpose Satellite-5 (KOMPSAT-5) with a synthetic aperture radar (SAR). Ground targets are essential in SAR image calibration. The environment for the deployment of ground targets for SAR image calibration should provide uniformity and minimum interference. The Amazon or deserts are regarded as desirable environments. However, such environments for SAR image calibration are difficult to find in Korea. Thus, it will be advantageous to have an active transponder whose performance will not be severely limited by the absence of such uniform environment. We have therefore developed an active transponder which has an adjustable internal delay and into which the orbit data of an arbitrary satellite can be loaded. The stored obit data with the aid of an internal global positioning system (GPS) receiver and gyroscope enables the active transponder to point to a selected satellite. In addition, a virtual deployment of the active transponder is possible due to its adjustable internal delay. Thus, the developed active transponder can be deployed at any place without environmental constraint. The performance of the developed active transponder is validated using the satellite TerraSAR-X, which is already in operation. The test results show that the active transponder is successfully compliant with the requirements for KOMPSAT-5 image calibration.

  17. System of acquisition and processing of images of dynamic speckle

    NASA Astrophysics Data System (ADS)

    Vega, F.; >C Torres,

    2015-01-01

    In this paper we show the design and implementation of a system to capture and analysis of dynamic speckle. The device consists of a USB camera, an isolated system lights for imaging, a laser pointer 633 nm 10 mw as coherent light source, a diffuser and a laptop for processing video. The equipment enables the acquisition and storage of video, also calculated of different descriptors of statistical analysis (vector global accumulation of activity, activity matrix accumulation, cross-correlation vector, autocorrelation coefficient, matrix Fujji etc.). The equipment is designed so that it can be taken directly to the site where the sample for biological study and is currently being used in research projects within the group.

  18. Experiences from long range passive and active imaging

    NASA Astrophysics Data System (ADS)

    Grönwall, Christina; Gustafsson, David; Steinvall, Ove; Tolt, Gustav

    2015-10-01

    We present algorithm evaluations for ATR of small sea vessels. The targets are at km distance from the sensors, which means that the algorithms have to deal with images affected by turbulence and mirage phenomena. We evaluate previously developed algorithms for registration of 3D-generating laser radar data. The evaluations indicate that some robustness to turbulence and mirage induced uncertainties can be handled by our probabilistic-based registration method. We also assess methods for target classification and target recognition on these new 3D data. An algorithm for detecting moving vessels in infrared image sequences is presented; it is based on optical flow estimation. Detection of moving target with an unknown spectral signature in a maritime environment is a challenging problem due to camera motion, background clutter, turbulence and the presence of mirage. First, the optical flow caused by the camera motion is eliminated by estimating the global flow in the image. Second, connected regions containing significant motions that differ from camera motion is extracted. It is assumed that motion caused by a moving vessel is more temporally stable than motion caused by mirage or turbulence. Furthermore, it is assumed that the motion caused by the vessel is more homogenous with respect to both magnitude and orientation, than motion caused by mirage and turbulence. Sufficiently large connected regions with a flow of acceptable magnitude and orientation are considered target regions. The method is evaluated on newly collected sequences of SWIR and MWIR images, with varying targets, target ranges and background clutter. Finally we discuss a concept for combining passive and active imaging in an ATR process. The main steps are passive imaging for target detection, active imaging for target/background segmentation and a fusion of passive and active imaging for target recognition.

  19. A translational registration system for LANDSAT image segments

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Erthal, G. J.; Velasco, F. R. D.; Mascarenhas, N. D. D.

    1983-01-01

    The use of satellite images obtained from various dates is essential for crop forecast systems. In order to make possible a multitemporal analysis, it is necessary that images belonging to each acquisition have pixel-wise correspondence. A system developed to obtain, register and record image segments from LANDSAT images in computer compatible tapes is described. The translational registration of the segments is performed by correlating image edges in different acquisitions. The system was constructed for the Burroughs B6800 computer in ALGOL language.

  20. Video Imaging System Particularly Suited for Dynamic Gear Inspection

    NASA Technical Reports Server (NTRS)

    Broughton, Howard (Inventor)

    1999-01-01

    A digital video imaging system that captures the image of a single tooth of interest of a rotating gear is disclosed. The video imaging system detects the complete rotation of the gear and divide that rotation into discrete time intervals so that each tooth of interest of the gear is precisely determined when it is at a desired location that is illuminated in unison with a digital video camera so as to record a single digital image for each tooth. The digital images are available to provide instantaneous analysis of the tooth of interest, or to be stored and later provide images that yield a history that may be used to predict gear failure, such as gear fatigue. The imaging system is completely automated by a controlling program so that it may run for several days acquiring images without supervision from the user.

  1. The design of a distributed image processing and dissemination system

    SciTech Connect

    Rafferty, P.; Hower, L.

    1990-01-01

    The design and implementation of a distributed image processing and dissemination system was undertaken and accomplished as part of a prototype communication and intelligence (CI) system, the contingency support system (CSS), which is intended to support contingency operations of the Tactical Air Command. The system consists of six (6) Sun 3/180C workstations with integrated ITEX image processors and three (3) 3/50 diskless workstations located at four (4) system nodes (INEL, base, and mobiles). All 3/180C workstations are capable of image system server functions where as the 3/50s are image system clients only. Distribution is accomplished via both local and wide area networks using standard Defense Data Network (DDN) protocols (i.e., TCP/IP, et al.) and Defense Satellite Communication Systems (DSCS) compatible SHF Transportable Satellite Earth Terminals (TSET). Image applications utilize Sun's Remote Procedure Call (RPC) to facilitate the image system client and server relationships. The system provides functions to acquire, display, annotate, process, transfer, and manage images via an icon, panel, and menu oriented Sunview{trademark} based user interface. Image spatial resolution is 512 {times} 480 with 8-bits/pixel black and white and 12/24 bits/pixel color depending on system configuration. Compression is used during various image display and transmission functions to reduce the dynamic range of image data of 12/6/3/2 bits/pixel depending on the application. Image acquisition is accomplished in real-time or near-real-time by special purpose Itex image hardware. As a result all image displays are highly interactive with attention given to subsecond response time. 3 refs., 7 figs.

  2. Three-dimensional imaging simulation of active laser detection based on DLOS method

    NASA Astrophysics Data System (ADS)

    Zhang, Chuanxin; Zhou, Honghe; Chen, Xiang; Yuan, Yuan; Shuai, Yong; Tan, Heping

    2016-07-01

    The technology of active laser detection is widely used in many different fields nowadays. With the development of computer technology, programmable software simulation can provide reference for the design of active laser detection. The characteristics of the active laser detecting systems also can be judged more visual. Based on the features of the active laser detection, an improved method of radiative transfer calculation (Double Line Of Sight) was developed, and the simulation models of complete active laser detecting imaging were founded. Compared with the results calculated by the Monte Carlo method, the correctness of the improved method was verified. The results of active laser detecting imaging of complex three-dimensional targets in different atmospheric scenes were compared. The influence of different atmospheric dielectric property were analyzed, which provides effective reference for the design of active laser detection.

  3. Noninvasive three-dimensional electrocardiographic imaging of ventricular activation sequence.

    PubMed

    Zhang, Xin; Ramachandra, Indiresha; Liu, Zhongming; Muneer, Basharat; Pogwizd, Steven M; He, Bin

    2005-12-01

    Imaging the myocardial activation sequence is critical for improved diagnosis and treatment of life-threatening cardiac arrhythmias. It is desirable to reveal the underlying cardiac electrical activity throughout the three-dimensional (3-D) myocardium (rather than just the endocardial or epicardial surface) from noninvasive body surface potential measurements. A new 3-D electrocardiographic imaging technique (3-DEIT) based on the boundary element method (BEM) and multiobjective nonlinear optimization has been applied to reconstruct the cardiac activation sequences from body surface potential maps. Ultrafast computerized tomography scanning was performed for subsequent construction of the torso and heart models. Experimental studies were then conducted, during left and right ventricular pacing, in which noninvasive assessment of ventricular activation sequence by means of 3-DEIT was performed simultaneously with 3-D intracardiac mapping (up to 200 intramural sites) using specially designed plunge-needle electrodes in closed-chest rabbits. Estimated activation sequences from 3-DEIT were in good agreement with those constructed from simultaneously recorded intracardiac electrograms in the same animals. Averaged over 100 paced beats (from a total of 10 pacing sites), total activation times were comparable (53.3 +/- 8.1 vs. 49.8 +/- 5.2 ms), the localization error of site of initiation of activation was 5.73 +/- 1.77 mm, and the relative error between the estimated and measured activation sequences was 0.32 +/- 0.06. The present experimental results demonstrate that the 3-D paced ventricular activation sequence can be reconstructed by using noninvasive multisite body surface electrocardiographic measurements and imaging of heart-torso geometry. This new 3-D electrocardiographic imaging modality has the potential to guide catheter-based ablative interventions for the treatment of life-threatening cardiac arrhythmias.

  4. Lensless imaging system to quantify cell proliferation

    NASA Astrophysics Data System (ADS)

    Vinjimore Kesavan, S.; Allier, C. P.; Navarro, F.; Mittler, F.; Chalmond, B.; Dinten, J.-M.

    2013-02-01

    Owing to its simplicity, lensless imaging system is adept at continuous monitoring of adherent cells inside the incubator. The setup consists of a CMOS sensor with pixel pitch of 2.2 μm and field of view of 24 mm2, LED with a dominating wavelength of 525 nm, along with a pinhole of 150 μm as the source of illumination. The in-line hologram obtained from cells depends on the degree of cell-substrate adhesion. Drastic difference is observed between the holographic patterns of floating and adherent cells. In addition, the well-established fact of reduction of cell-substrate contact during cell division is observed with our system based on corresponding spontaneous transition in the holographic pattern. Here, we demonstrate that by recognizing this specific holographic pattern, number of cells undergoing mitosis in a cell culture with a population of approximately 5000 cells, can be estimated in real-time. The method is assessed on comparison with Edu-based proliferation assay. The approach is straightforward and it eliminates the use of markers to estimate the proliferation rate of a given cell culture. Unlike most proliferation assays, the cells are not harvested enabling continuous monitoring of cell culture.

  5. Optimization of a Biometric System Based on Acoustic Images

    PubMed Central

    Izquierdo Fuente, Alberto; Del Val Puente, Lara; Villacorta Calvo, Juan J.; Raboso Mateos, Mariano

    2014-01-01

    On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced. PMID:24616643

  6. Optimization of a biometric system based on acoustic images.

    PubMed

    Izquierdo Fuente, Alberto; Del Val Puente, Lara; Villacorta Calvo, Juan J; Raboso Mateos, Mariano

    2014-01-01

    On the basis of an acoustic biometric system that captures 16 acoustic images of a person for 4 frequencies and 4 positions, a study was carried out to improve the performance of the system. On a first stage, an analysis to determine which images provide more information to the system was carried out showing that a set of 12 images allows the system to obtain results that are equivalent to using all of the 16 images. Finally, optimization techniques were used to obtain the set of weights associated with each acoustic image that maximizes the performance of the biometric system. These results improve significantly the performance of the preliminary system, while reducing the time of acquisition and computational burden, since the number of acoustic images was reduced.

  7. Operation and performance of the mars exploration rover imaging system on the martian surface

    USGS Publications Warehouse

    Maki, J.N.; Litwin, T.; Schwochert, M.; Herkenhoff, K.

    2005-01-01

    The Imaging System on the Mars Exploration Rovers has successfully operated on the surface of Mars for over one Earth year. The acquisition of hundreds of panoramas and tens of thousands of stereo pairs has enabled the rovers to explore Mars at a level of detail unprecedented in the history of space exploration. In addition to providing scientific value, the images also play a key role in the daily tactical operation of the rovers. The mobile nature of the MER surface mission requires extensive use of the imaging system for traverse planning, rover localization, remote sensing instrument targeting, and robotic arm placement. Each of these activity types requires a different set of data compression rates, surface coverage, and image acquisition strategies. An overview of the surface imaging activities is provided, along with a summary of the image data acquired to date. ?? 2005 IEEE.

  8. Gallbladder shape extraction from ultrasound images using active contour models.

    PubMed

    Ciecholewski, Marcin; Chochołowicz, Jakub

    2013-12-01

    Gallbladder function is routinely assessed using ultrasonographic (USG) examinations. In clinical practice, doctors very often analyse the gallbladder shape when diagnosing selected disorders, e.g. if there are turns or folds of the gallbladder, so extracting its shape from USG images using supporting software can simplify a diagnosis that is often difficult to make. The paper describes two active contour models: the edge-based model and the region-based model making use of a morphological approach, both designed for extracting the gallbladder shape from USG images. The active contour models were applied to USG images without lesions and to those showing specific disease units, namely, anatomical changes like folds and turns of the gallbladder as well as polyps and gallstones. This paper also presents modifications of the edge-based model, such as the method for removing self-crossings and loops or the method of dampening the inflation force which moves nodes if they approach the edge being determined. The user is also able to add a fragment of the approximated edge beyond which neither active contour model will move if this edge is incomplete in the USG image. The modifications of the edge-based model presented here allow more precise results to be obtained when extracting the shape of the gallbladder from USG images than if the morphological model is used.

  9. Monitoring dynamic systems with multiparameter fluorescence imaging.

    PubMed

    Kudryavtsev, Volodymyr; Felekyan, Suren; Woźniak, Anna K; König, Marcelle; Sandhagen, Carl; Kühnemuth, Ralf; Seidel, Claus A M; Oesterhelt, Filipp

    2007-01-01

    A new general strategy based on the use of multiparameter fluorescence detection (MFD) to register and quantitatively analyse fluorescence images is introduced. Multiparameter fluorescence imaging (MFDi) uses pulsed excitation, time-correlated single-photon counting and a special pixel clock to simultaneously monitor the changes in the eight-dimensional fluorescence information (fundamental anisotropy, fluorescence lifetime, fluorescence intensity, time, excitation spectrum, fluorescence spectrum, fluorescence quantum yield, distance between fluorophores) in real time. The three spatial coordinates are also stored. The most statistically efficient techniques known from single-molecule spectroscopy are used to estimate fluorescence parameters of interest for all pixels, not just for the regions of interest. Their statistical significance is judged from a stack of two-dimensional histograms. In this way, specific pixels can be selected for subsequent pixel-based subensemble analysis in order to improve the statistical accuracy of the parameters estimated. MFDi avoids the need for sequential measurements, because the registered data allow one to perform many analysis techniques, such as fluorescence-intensity distribution analysis (FIDA) and fluorescence correlation spectroscopy (FCS), in an off-line mode. The limitations of FCS for counting molecules and monitoring dynamics are discussed. To demonstrate the ability of our technique, we analysed two systems: (i) interactions of the fluorescent dye Rhodamine 110 inside and outside of a glutathione sepharose bead, and (ii) microtubule dynamics in live yeast cells of Schizosaccharomyces pombe using a fusion protein of Green Fluorescent Protein (GFP) with Minichromosome Altered Loss Protein 3 (Mal3), which is involved in the dynamic cycle of polymerising and depolymerising microtubules. PMID:17160654

  10. Non-uniform system response detection for hyperspectral imaging systems

    NASA Astrophysics Data System (ADS)

    Castorena, Juan; Morrison, Jason; Paliwal, Jitendra; Erkinbaev, Chyngyz

    2015-11-01

    Near infrared (NIR) hyperspectral imaging (HSI) has established itself as a powerful non-destructive tool for the chemical analysis of heterogeneous samples. However, one of the main disadvantages of NIR HSI is that the technique suffers from instrumentation-related problems, which in turn affect the acquired images. In general, focal plane array (FPA) based hyperspectral systems are affected by spatial and spectral non-uniform response, the presence of defective sensors (e.g. dead or saturated sensors), and temporal and spatial (e.g. dark current) noise. Another issue is each new camera system needs to be calibrated to assess its specific responses to light. To correct for these issues, we used known standards to measure the response of the sensors and capture the location of the field of view and defective sensors using linear and quadratic models. The parameters of these models were then used as input features for classification of sensor responses using a k-means algorithm. The results conclude that linear models are insufficiently precise for calibration but estimate sufficiently accurately the system's response and functionality. Specifically, it was shown that the classification method discriminates non-responsive regions effectively.

  11. Towards Depth-Resolved Optical Imaging of Cardiac Electrical Activity.

    PubMed

    Walton, Richard D; Bernus, Olivier

    2015-01-01

    The spatiotemporal dynamics of arrhythmias are likely to be complex three-dimensional phenomena. Yet, the lack of high-resolution three-dimensional imaging techniques, both in the clinic and the experimental lab, limits our ability to better understand the mechanisms of such arrhythmias. Optical mapping using voltage-sensitive dyes is a widely used tool in experimental electrophysiology. It has been known for decades that even in its most basic application, epi-fluorescence, the optical signal contains information from within a certain intramural volume. Understanding of this fundamental property of optical signals has paved the way towards novel three-dimensional optical imaging techniques. Here, we review our current understanding of the three-dimensional nature of optical signals; how penetration depths of cardiac optical imaging can be improved by using novel imaging modalities and finally, we highlight new techniques inspired from optical tomography and aiming at full depth-resolved optical mapping of cardiac electrical activity. PMID:26238062

  12. Imaging through turbulence with temporally and spatially multiplexed systems

    NASA Astrophysics Data System (ADS)

    Vdovin, Gleb; Soloviev, Oleg; Loktev, Mikhail; Savenko, Slava

    2011-11-01

    Based on the analysis of factors that influence atmospheric imaging over long turbulent horizontal paths, we consider a number of practical configurations of opto-electronic surveillance systems with optimized performance. Our approach is based on simultaneous quasi real-time processing of a number of images obtained through uncorrelated atmospheric paths, using either temporal or spatial multiplexing. Practical results obtained on a 4.25 km imaging path using newly developed imaging system, based on temporal multiplexing, combined with image restoration based on projection on convex sets, are reported. Potential applications include optical and IR long-range security and military surveillance, unmanned aircraft imaging systems and naval optical imaging and warning systems.

  13. Integrating medical imaging analyses through a high-throughput bundled resource imaging system

    NASA Astrophysics Data System (ADS)

    Covington, Kelsie; Welch, E. Brian; Jeong, Ha-Kyu; Landman, Bennett A.

    2011-03-01

    Exploitation of advanced, PACS-centric image analysis and interpretation pipelines provides well-developed storage, retrieval, and archival capabilities along with state-of-the-art data providence, visualization, and clinical collaboration technologies. However, pursuit of integrated medical imaging analysis through a PACS environment can be limiting in terms of the overhead required to validate, evaluate and integrate emerging research technologies. Herein, we address this challenge through presentation of a high-throughput bundled resource imaging system (HUBRIS) as an extension to the Philips Research Imaging Development Environment (PRIDE). HUBRIS enables PACS-connected medical imaging equipment to invoke tools provided by the Java Imaging Science Toolkit (JIST) so that a medical imaging platform (e.g., a magnetic resonance imaging scanner) can pass images and parameters to a server, which communicates with a grid computing facility to invoke the selected algorithms. Generated images are passed back to the server and subsequently to the imaging platform from which the images can be sent to a PACS. JIST makes use of an open application program interface layer so that research technologies can be implemented in any language capable of communicating through a system shell environment (e.g., Matlab, Java, C/C++, Perl, LISP, etc.). As demonstrated in this proof-of-concept approach, HUBRIS enables evaluation and analysis of emerging technologies within well-developed PACS systems with minimal adaptation of research software, which simplifies evaluation of new technologies in clinical research and provides a more convenient use of PACS technology by imaging scientists.

  14. Development of a PET/Cerenkov-light hybrid imaging system

    SciTech Connect

    Yamamoto, Seiichi Hamamura, Fuka; Kato, Katsuhiko; Ogata, Yoshimune; Watabe, Tadashi; Ikeda, Hayato; Kanai, Yasukazu; Hatazawa, Jun; Watabe, Hiroshi

    2014-09-15

    Purpose: Cerenkov-light imaging is a new molecular imaging technology that detects visible photons from high-speed electrons using a high sensitivity optical camera. However, the merit of Cerenkov-light imaging remains unclear. If a PET/Cerenkov-light hybrid imaging system were developed, the merit of Cerenkov-light imaging would be clarified by directly comparing these two imaging modalities. Methods: The authors developed and tested a PET/Cerenkov-light hybrid imaging system that consists of a dual-head PET system, a reflection mirror located above the subject, and a high sensitivity charge coupled device (CCD) camera. The authors installed these systems inside a black box for imaging the Cerenkov-light. The dual-head PET system employed a 1.2 × 1.2 × 10 mm{sup 3} GSO arranged in a 33 × 33 matrix that was optically coupled to a position sensitive photomultiplier tube to form a GSO block detector. The authors arranged two GSO block detectors 10 cm apart and positioned the subject between them. The Cerenkov-light above the subject is reflected by the mirror and changes its direction to the side of the PET system and is imaged by the high sensitivity CCD camera. Results: The dual-head PET system had a spatial resolution of ∼1.2 mm FWHM and sensitivity of ∼0.31% at the center of the FOV. The Cerenkov-light imaging system's spatial resolution was ∼275μm for a {sup 22}Na point source. Using the combined PET/Cerenkov-light hybrid imaging system, the authors successfully obtained fused images from simultaneously acquired images. The image distributions are sometimes different due to the light transmission and absorption in the body of the subject in the Cerenkov-light images. In simultaneous imaging of rat, the authors found that {sup 18}F-FDG accumulation was observed mainly in the Harderian gland on the PET image, while the distribution of Cerenkov-light was observed in the eyes. Conclusions: The authors conclude that their developed PET/Cerenkov-light hybrid

  15. Image capture and printing system for digitally generated medical-diagnostic images

    NASA Astrophysics Data System (ADS)

    Stone, Barry; Bronkalla, Mark D.

    1990-08-01

    The printing of digitally generated images from medical diagnostic equipment has typically been done on analog systems after D to A conversion. Newer digital printing systems do not generally yield optimum results since they re-sample the incoming video signal according to their own internal pixel matrix. This leads to a loss of contrast and resolution plus the introduction of aliasing artifacts into the image. Using the method of synchronous sampling of the incoming video signal an almost perfect digitization of the original image can be achieved. Starting with the known display pixel matrix the pixel display clock can be regenerated by a precision phase locked frequency synthesizer. Quantizing levels are duplicated through calibration of the system. Sampling phase error is adjusted out such that each pixel is sampled at its center. Comparison with non-synchronous techniques and multi-generation performance of this system will be demonstrated. The images are then transferred digitally on disk for storage and later printing by a CRT based slow scan camera system. Image parameter files saved with the image allow the camera to generate a gamma correction look-up table for printing. The film image will then precisely and consistently match the CRT image viewed by the system operator. The system is capable of digitizing and printing up to 10242 images with the same high quality as the original displayed image.

  16. Noninvasive Molecular Imaging of Disease Activity in Atherosclerosis.

    PubMed

    Dweck, Marc R; Aikawa, Elena; Newby, David E; Tarkin, Jason M; Rudd, James H F; Narula, Jagat; Fayad, Zahi A

    2016-07-01

    Major focus has been placed on the identification of vulnerable plaques as a means of improving the prediction of myocardial infarction. However, this strategy has recently been questioned on the basis that the majority of these individual coronary lesions do not in fact go on to cause clinical events. Attention is, therefore, shifting to alternative imaging modalities that might provide a more complete pan-coronary assessment of the atherosclerotic disease process. These include markers of disease activity with the potential to discriminate between patients with stable burnt-out disease that is no longer metabolically active and those with active atheroma, faster disease progression, and increased risk of infarction. This review will examine how novel molecular imaging approaches can provide such assessments, focusing on inflammation and microcalcification activity, the importance of these processes to coronary atherosclerosis, and the advantages and challenges posed by these techniques. PMID:27390335

  17. Considerations for imaging system implementation in a networked environment

    SciTech Connect

    Hudson, B.J.

    1991-01-01

    Information storage and retrieval systems that utilize raster images are increasing in popularity on a wide variety of platforms. Image systems typically involve the transmission of data files in the 100 KiloByte to 1 MegaByte range to users on specialized workstations who expect retrieval in a matter of seconds. The results of the pilot study outlines the potential for the sharing of image information among various platforms and systems, and sets expectations regarding the level of integration.

  18. Considerations for imaging system implementation in a networked environment

    SciTech Connect

    Hudson, B.J.

    1991-12-31

    Information storage and retrieval systems that utilize raster images are increasing in popularity on a wide variety of platforms. Image systems typically involve the transmission of data files in the 100 KiloByte to 1 MegaByte range to users on specialized workstations who expect retrieval in a matter of seconds. The results of the pilot study outlines the potential for the sharing of image information among various platforms and systems, and sets expectations regarding the level of integration.

  19. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the features of continuous wave doppler-effect technology with pulsed-echo effect technology and is intended...

  20. 21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed echo imaging system. 892.1560 Section 892.1560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed echo imaging system is a device intended to project...

  1. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines...

  2. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550 Section 892.1550 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines...

  3. 21 CFR 892.1560 - Ultrasonic pulsed echo imaging system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic pulsed echo imaging system. 892.1560 Section 892.1560 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... system. (a) Identification. An ultrasonic pulsed echo imaging system is a device intended to project...

  4. Temporal muscle activation assessment by ultrasound imaging during flexor withdrawal reflex and voluntary contraction.

    PubMed

    Jose, Gomez-Tames; Shuto, Nakamura; Jose, Gonzalez; Wenwei, Yu

    2013-01-01

    Activating flexor reflexes by electrical stimulation has been used as a mechanism to initiate the swing phase or to enhance it for spinal cord injured patients. However, it is necessary to know their contraction dynamics in order to artificially induce them at the right moment of a walking cycle. This requires understanding the temporal activation pattern of both surface and deep muscles simultaneously. This study aimed at developing a system to measure and analyze the temporal activation of both surface and deep muscles during voluntary contraction and flexor reflexes (also called withdrawal reflexes) using ultrasound imaging. A set of experiments were done to verify the validity of the system, while exploring the temporal pattern of muscle activation during flexor reflexes. As a result, we were able to quantify the surface and deep muscle activity by measuring the muscle thickness, pennation angle and long-axis displacement, from the ultrasound images.

  5. Resolution-enhancement for an orthographic-view image display in an integral imaging microscope system

    PubMed Central

    Kwon, Ki-Chul; Jeong, Ji-Seong; Erdenebat, Munkh-Uchral; Piao, Yan-Ling; Yoo, Kwan-Hee; Kim, Nam

    2015-01-01

    Due to the limitations of micro lens arrays and camera sensors, images on display devices through the integral imaging microscope systems have been suffering for a low-resolution. In this paper, a resolution-enhanced orthographic-view image display method for integral imaging microscopy is proposed and demonstrated. Iterative intermediate-view reconstructions are performed based on bilinear interpolation using neighborhood elemental image information, and a graphics processing unit parallel processing algorithm is applied for fast image processing. The proposed method is verified experimentally and the effective results are presented in this paper. PMID:25798299

  6. Electrochemiluminescence imaging for parallel single-cell analysis of active membrane cholesterol.

    PubMed

    Zhou, Junyu; Ma, Guangzhong; Chen, Yun; Fang, Danjun; Jiang, Dechen; Chen, Hong-Yuan

    2015-08-18

    Luminol electrochemiluminescence (ECL) imaging was developed for the parallel measurement of active membrane cholesterol at single living cells, thus establishing a novel electrochemical detection technique for single cells with high analysis throughput and low detection limit. In our strategy, the luminescence generated from luminol and hydrogen peroxide upon the potential was recorded in one image so that hydrogen peroxide at the surface of multiple cells could be simultaneously analyzed. Compared with the classic microelectrode array for the parallel single-cell analysis, the plat electrode only was needed in our ECL imaging, avoiding the complexity of electrode fabrication. The optimized ECL imaging system showed that hydrogen peroxide as low as 10 μM was visible and the efflux of hydrogen peroxide from cells could be determined. Coupled with the reaction between active membrane cholesterol and cholesterol oxidase to generate hydrogen peroxide, active membrane cholesterol at cells on the electrode was analyzed at single-cell level. The luminescence intensity was correlated with the amount of active membrane cholesterol, validating our system for single-cell cholesterol analysis. The relative high standard deviation on the luminescence suggested high cellular heterogeneities on hydrogen peroxide efflux and active membrane cholesterol, which exhibited the significance of single-cell analysis. This success in ECL imaging for single-cell analysis opens a new field in the parallel measurement of surface molecules at single cells.

  7. Body Image and Physical Activity in British Secondary School Children

    ERIC Educational Resources Information Center

    Duncan, Michael J.; Al-Nakeeb, Yahya; Nevill, Alan; Jones, Marc V.

    2004-01-01

    This study assessed the relationship between children's body image and physical activity and examined any variation in these variables. Two hundred and seventy seven British secondary school children aged 11 to 14 (mean age [plus or minus] SD = 12.5 [plus or minus] 0.8 years) participated in this study. Results indicated no significant…

  8. Browsing Image Collections with Representations of Common-Sense Activities.

    ERIC Educational Resources Information Center

    Gordon, Andrew S.

    2001-01-01

    Describes a methodology for creating networks of subject terms by manually representing a large number of common-sense activities that are broadly related to image subject terms. Application of this methodology to the Library of Congress Thesaurus for Graphic Materials produced 768 representations that supported users of a prototype browsing-based…

  9. Active spectral imaging for standoff detection of explosives

    SciTech Connect

    Skvortsov, L A

    2011-12-31

    Laser methods of standoff detection of explosive traces on surfaces of objects are considered. These methods are based on active formation of multi- and hyperspectral images of an object examined. The possibilities of these methods and the prospects of their development are discussed. Emphasis is laid on the justification of the most preferred field of application of the technique under consideration.

  10. Counter sniper: a localization system based on dual thermal imager

    NASA Astrophysics Data System (ADS)

    He, Yuqing; Liu, Feihu; Wu, Zheng; Jin, Weiqi; Du, Benfang

    2010-11-01

    Sniper tactics is widely used in modern warfare, which puts forward the urgent requirement of counter sniper detection devices. This paper proposed the anti-sniper detection system based on a dual-thermal imaging system. Combining the infrared characteristics of the muzzle flash and bullet trajectory of binocular infrared images obtained by the dual-infrared imaging system, the exact location of the sniper was analyzed and calculated. This paper mainly focuses on the system design method, which includes the structure and parameter selection. It also analyzes the exact location calculation method based on the binocular stereo vision and image analysis, and give the fusion result as the sniper's position.

  11. Review of development of laser active imaging technology in China and foreign countries

    NASA Astrophysics Data System (ADS)

    Fan, Youchen; Zhao, Hongli; Li, Yingcun

    2014-11-01

    Range-gated laser active imaging technology is an effective way to image detection and precise tracking of remote, dark, and small targets that overcomes the shortcomings of passive visible or infrared imaging technology, thus has important practical value and broad application prospects in the military. The paper based on the analysis of its principle, technical advantages and key technologies focus on the typical systems under atmospheric conditions at home and abroad and the latest research results, and discusses the development trends of this technology.

  12. Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle

    SciTech Connect

    Chektybayev, B. Shapovalov, G.; Kolodeshnikov, A.

    2015-05-15

    In the paper, new visible wide angle view imaging system of KTM tokamak is described. The system has been designed to observe processes inside of plasma and the processes occurring due to plasma-wall interactions through the long equatorial port. Imaging system is designed based on special image fiber bundle and entrance wide angle lens, which provide image of large section of the vacuum chamber, both poloidal half-section and divertor through the sufficiently long equatorial port. The system also consists of two video cameras: slow and fast with image intensifier. Commercial equipment had been used in design of the system that allowed reducing the cost and time for research and development. The paper also discusses advantages and disadvantages of the system in comparison with conventional endoscopes based on a lens system and considers its promising utilization in future tokamaks and future steady state fusion reactors.

  13. Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle

    NASA Astrophysics Data System (ADS)

    Chektybayev, B.; Shapovalov, G.; Kolodeshnikov, A.

    2015-05-01

    In the paper, new visible wide angle view imaging system of KTM tokamak is described. The system has been designed to observe processes inside of plasma and the processes occurring due to plasma-wall interactions through the long equatorial port. Imaging system is designed based on special image fiber bundle and entrance wide angle lens, which provide image of large section of the vacuum chamber, both poloidal half-section and divertor through the sufficiently long equatorial port. The system also consists of two video cameras: slow and fast with image intensifier. Commercial equipment had been used in design of the system that allowed reducing the cost and time for research and development. The paper also discusses advantages and disadvantages of the system in comparison with conventional endoscopes based on a lens system and considers its promising utilization in future tokamaks and future steady state fusion reactors.

  14. Visible wide angle view imaging system of KTM tokamak based on multielement image fiber bundle.

    PubMed

    Chektybayev, B; Shapovalov, G; Kolodeshnikov, A

    2015-05-01

    In the paper, new visible wide angle view imaging system of KTM tokamak is described. The system has been designed to observe processes inside of plasma and the processes occurring due to plasma-wall interactions through the long equatorial port. Imaging system is designed based on special image fiber bundle and entrance wide angle lens, which provide image of large section of the vacuum chamber, both poloidal half-section and divertor through the sufficiently long equatorial port. The system also consists of two video cameras: slow and fast with image intensifier. Commercial equipment had been used in design of the system that allowed reducing the cost and time for research and development. The paper also discusses advantages and disadvantages of the system in comparison with conventional endoscopes based on a lens system and considers its promising utilization in future tokamaks and future steady state fusion reactors.

  15. (New imaging systems in nuclear medicine)

    SciTech Connect

    Not Available

    1990-01-01

    Further progress has been made on improving the uniformity and stability of PCR-I, the single ring analog coded tomograph. This camera has been employed in a wide range of animal studies described below. Data from PCR-I have been used in various image processing procedures. These include motion pictures of dog heart, comparison of PET and MRI image in dog heart and rat brain and quantitation of tumor metabolism in the nude mouse using blood data from heart images. A SUN workstation with TAAC board has been used to produce gated three-dimensional images of the dog heart. The ANALYZE program from the Mayo Clinic has also been mounted on a SUN workstation for comparison of images and image processing. 15 refs., 6 figs.

  16. Quantitative Luminescence Imaging System description and user's manual

    SciTech Connect

    Stahl, K.A.; Batishko, C.R.

    1988-06-01

    A Quantitative Luminescence Imaging System (QLIS) was designed and constructed. The system was developed for use in imaging and quantitative analysis of very low light level chemiluminescent phenomena. The luminescent reactions are imaged via microchannel plate image intensifier coupled to a newvicon video camera. The video record of the reaction can be stored on video tape or digitally captured by an image processing system which is integral to a host computer controller. Since the particular experimental conditions for which the QLIS was designed necessitate that the chemiluminescent reaction take place in an rf flux within a waveguide, the system includes a coherent fiber optic image transfer system which allows the video hardware to be mounted externally to the rf waveguide.

  17. A knowledge-anchored integrative image search and retrieval system.

    PubMed

    Erdal, Selnur; Catalyurek, Umit V; Payne, Philip R O; Saltz, Joel; Kamal, Jyoti; Gurcan, Metin N

    2009-04-01

    Clinical data that may be used in a secondary capacity to support research activities are regularly stored in three significantly different formats: (1) structured, codified data elements; (2) semi-structured or unstructured narrative text; and (3) multi-modal images. In this manuscript, we will describe the design of a computational system that is intended to support the ontology-anchored query and integration of such data types from multiple source systems. Additional features of the described system include (1) the use of Grid services-based electronic data interchange models to enable the use of our system in multi-site settings and (2) the use of a software framework intended to address both potential security and patient confidentiality concerns that arise when transmitting or otherwise manipulating potentially privileged personal health information. We will frame our discussion within the specific experimental context of the concept-oriented query and integration of correlated structured data, narrative text, and images for cancer research. PMID:18040742

  18. Laser applications and system considerations in ocular imaging

    PubMed Central

    Elsner, Ann E.; Muller, Matthew S.

    2009-01-01

    We review laser applications for primarily in vivo ocular imaging techniques, describing their constraints based on biological tissue properties, safety, and the performance of the imaging system. We discuss the need for cost effective sources with practical wavelength tuning capabilities for spectral studies. Techniques to probe the pathological changes of layers beneath the highly scattering retina and diagnose the onset of various eye diseases are described. The recent development of several optical coherence tomography based systems for functional ocular imaging is reviewed, as well as linear and nonlinear ocular imaging techniques performed with ultrafast lasers, emphasizing recent source developments and methods to enhance imaging contrast. PMID:21052482

  19. HOPIS: hybrid omnidirectional and perspective imaging system for mobile robots.

    PubMed

    Lin, Huei-Yung; Wang, Min-Liang

    2014-01-01

    In this paper, we present a framework for the hybrid omnidirectional and perspective robot vision system. Based on the hybrid imaging geometry, a generalized stereo approach is developed via the construction of virtual cameras. It is then used to rectify the hybrid image pair using the perspective projection model. The proposed method not only simplifies the computation of epipolar geometry for the hybrid imaging system, but also facilitates the stereo matching between the heterogeneous image formation. Experimental results for both the synthetic data and real scene images have demonstrated the feasibility of our approach. PMID:25192317

  20. HOPIS: hybrid omnidirectional and perspective imaging system for mobile robots.

    PubMed

    Lin, Huei-Yung; Wang, Min-Liang

    2014-09-04

    In this paper, we present a framework for the hybrid omnidirectional and perspective robot vision system. Based on the hybrid imaging geometry, a generalized stereo approach is developed via the construction of virtual cameras. It is then used to rectify the hybrid image pair using the perspective projection model. The proposed method not only simplifies the computation of epipolar geometry for the hybrid imaging system, but also facilitates the stereo matching between the heterogeneous image formation. Experimental results for both the synthetic data and real scene images have demonstrated the feasibility of our approach.